WorldWideScience

Sample records for rendering virtual endoscopy

  1. Three dimensional volume rendering virtual endoscopy of the ossicles using a multi-row detector CT: applications and limitations

    International Nuclear Information System (INIS)

    Kim, Su Yeon; Choi, Sun Seob; Kang, Myung Jin; Shin, Tae Beom; Lee, Ki Nam; Kang, Myung Koo

    2005-01-01

    This study was conducted to know the applications and limitations of three dimensional volume rendering virtual endoscopy of the ossicles using a multi-row detector CT. This study examined 25 patients who underwent temporal bone CT using a 16-row detector CT as a result of hearing problems or trauma. The axial CT scan of the temporal bone was performed with a 0.6 mm collimation, and a reconstruction was carried out with a U70u sharp of kernel value, a 1 mm thickness and 0.5-1.0 mm increments. After observing the ossicles in the axial and coronal images, virtual endoscopy was performed using a three dimensional volume rendering technique with a threshold value of-500 HU. The intra-operative otoendoscopy was performed in 12 ears, and was compared with the virtual endoscopy findings. Virtual endoscopy of the 29 ears without hearing problems demonstrated hypoplastic or an incomplete depiction of the stapes superstructures in 25 ears and a normal depiction in 4 ears. Virtual endoscopy of 21 ears with hearing problems demonstrated no ossicles in 1 ears, no malleus in 3 ears, a malleoincudal subluxation in 6 ears, a dysplastic incus in 5 ears, an incudostapedial subluxation in 9 ears, dysplastic stapes in 2 ears, a hypoplastic or incomplete depiction of the stapes in 16 ears and no stapes in 1 ears. In contrast to the intra-operative otoendoscopy, 8 out of 12 ears showed a hypoplastic or deformed stapes in the virtual endoscopy. Volume rendering virtual endoscopy using a multi-row detector CT is an excellent method for evaluation the ossicles in three dimension, even thought the partial volume effect for the stapes superstructures needs to be considered

  2. Virtual MR endoscopy of the ventricles prior to neurosurgical interventional endoscopy - evaluation of different presentation techniques

    International Nuclear Information System (INIS)

    Lemke, A.J.; Schurig-Urbaniak, A.M.; Niehues, S.M.; Felix, R.; Liebig, T.

    2004-01-01

    Purpose: In the past, virtual endoscopies have been performed for planning of endoscopic interventions or for diagnostic purposes in various organ systems with increasing frequency. This study evaluates the ability of virtual ventricular endoscopy to depict anatomical structures and the use for planning of real endoscopy. Materials and Methods: In a prospective study, 4 volunteers and 8 patients were examined with MRI. In 3 of the patients endoscopy was performed by our neurosurgeons thereafter. The calculation of the virtual endoscopy was based on 1 mm sagittal T2-weighted images. Comparison of surface rendering and volume rendering was made by means of video sequencing of individual views, and these were compared with the intraoperative endoscopic videos concerning the depictability of anatomical landmarks. Results: The reconstructions using volume rendering were more significant and easier to calculate than those based on surface rendering. Virtual endoscopy in the transparent mode allowed visualization of hazardous structures outside the ventricular system such as the basilar artery tip. Transparent 3D images of the ventricles gave a good overview on the depicted structures and enabled a better orientation during the virtual camera flight than surface rendered views. Conclusion: MR-based virtual endoscopy of the ventricular system can be obtained on the basis of surface- and volume-rendered views of sagittal T2-weighted thin sections. Preoperative utilization of this method simplifies the planning of endoscopy by visualization of anatomical structures. (orig.)

  3. Hybrid rendering of the chest and virtual bronchoscopy [corrected].

    Science.gov (United States)

    Seemann, M D; Seemann, O; Luboldt, W; Gebicke, K; Prime, G; Claussen, C D

    2000-10-30

    Thin-section spiral computed tomography was used to acquire the volume data sets of the thorax. The tracheobronchial system and pathological changes of the chest were visualized using a color-coded surface rendering method. The structures of interest were then superimposed on a volume rendering of the other thoracic structures, thus producing a hybrid rendering. The hybrid rendering technique exploit the advantages of both rendering methods and enable virtual bronchoscopic examinations using different representation models. Virtual bronchoscopic examinations with a transparent color-coded shaded-surface model enables the simultaneous visualization of both the airways and the adjacent structures behind of the tracheobronchial wall and therefore, offers a practical alternative to fiberoptic bronchoscopy. Hybrid rendering and virtual endoscopy obviate the need for time consuming detailed analysis and presentation of axial source images.

  4. Virtual endoscopy and 3D volume rendering in the management of frontal sinus fractures.

    Science.gov (United States)

    Belina, Stanko; Cuk, Viseslav; Klapan, Ivica

    2009-12-01

    Frontal sinus fractures (FSF) are commonly caused by traffic accidents, assaults, industrial accidents and gunshot wounds. Classical roentgenography has high proportion of false negative findings in cases of FSF and is not particularly useful in examining the severity of damage to the frontal sinus posterior table and the nasofrontal duct region. High resolution computed tomography was inavoidable during the management of such patients but it may produce large quantity of 2D images. Postprocessing of datasets acquired by high resolution computer tomography from patients with severe head trauma may offer a valuable additional help in diagnostics and surgery planning. We performed virtual endoscopy (VE) and 3D volume rendering (3DVR) on high resolution CT data acquired from a 54-year-old man with with both anterior and posterior frontal sinus wall fracture in order to demonstrate advantages and disadvantages of these methods. Data acquisition was done by Siemens Somatom Emotion scanner and postprocessing was performed with Syngo 2006G software. VE and 3DVR were performed in a man who suffered blunt trauma to his forehead and nose in an traffic accident. Left frontal sinus anterior wall fracture without dislocation and fracture of tabula interna with dislocation were found. 3D position and orientation of fracture lines were shown in by 3D rendering software. We concluded that VE and 3DVR can clearly display the anatomic structure of the paranasal sinuses and nasopharyngeal cavity, revealing damage to the sinus wall caused by a fracture and its relationship to surrounding anatomical structures.

  5. Usefulness of virtual endoscopy for evaluating the relationship between the neck of intracranial aneurysm and surrounding vessels

    International Nuclear Information System (INIS)

    Ikeda, Jota; Horie, Hitoshi; Ishikura, Reiichi; Ando, Kumiko; Morikawa, Tsutomu; Tominaga, Satoru; Nakao, Norio

    2000-01-01

    Application of three-dimensional CT virtual endoscopy for evaluation of the neck and surrounding vessels of intracranial aneurysms. 3D-CT virtual endoscopy (VE) is a reconstructed image using computer processing of 3D-CT images. We evaluated the usefulness of a virtual endoscopy to analyze the relationship between the neck of an intracranial aneurysm and the surrounding vessels. Eight cases with intracranial aneurysms underwent digital subtraction angiography (DSA) and enhanced CT with transarterial infusion of contrast media. 3D-CT angiogram (3D-CTA) and virtual endoscopic images were obtained from the CT image data sets using surface rendering method. The relationship between the neck of an intracranial aneurysm and the surrounding vessels was confirmed by operation or IVR. VE clearly visualized the neck and surrounding vessels in all cases. Operation/IVR findings agreed with the virtual endoscopic findings in all cases, but not with the DSA or 3D-CTA findings in 4 and 2 cases, respectively. 3D-CTA and virtual endoscopy clearly visualizes the relationship between cerebral aneurysms and surrounding vessels, which is useful for determining IVR procedures. (author)

  6. Virtual reality simulators for gastrointestinal endoscopy training.

    Science.gov (United States)

    Triantafyllou, Konstantinos; Lazaridis, Lazaros Dimitrios; Dimitriadis, George D

    2014-01-16

    The use of simulators as educational tools for medical procedures is spreading rapidly and many efforts have been made for their implementation in gastrointestinal endoscopy training. Endoscopy simulation training has been suggested for ascertaining patient safety while positively influencing the trainees' learning curve. Virtual simulators are the most promising tool among all available types of simulators. These integrated modalities offer a human-like endoscopy experience by combining virtual images of the gastrointestinal tract and haptic realism with using a customized endoscope. From their first steps in the 1980s until today, research involving virtual endoscopic simulators can be divided in two categories: investigation of the impact of virtual simulator training in acquiring endoscopy skills and measuring competence. Emphasis should also be given to the financial impact of their implementation in endoscopy, including the cost of these state-of-the-art simulators and the potential economic benefits from their usage. Advances in technology will contribute to the upgrade of existing models and the development of new ones; while further research should be carried out to discover new fields of application.

  7. Virtual endoscopy in neurosurgery: a review.

    Science.gov (United States)

    Neubauer, André; Wolfsberger, Stefan

    2013-01-01

    Virtual endoscopy is the computerized creation of images depicting the inside of patient anatomy reconstructed in a virtual reality environment. It permits interactive, noninvasive, 3-dimensional visual inspection of anatomical cavities or vessels. This can aid in diagnostics, potentially replacing an actual endoscopic procedure, and help in the preparation of a surgical intervention by bridging the gap between plain 2-dimensional radiologic images and the 3-dimensional depiction of anatomy during actual endoscopy. If not only the endoscopic vision but also endoscopic handling, including realistic haptic feedback, is simulated, virtual endoscopy can be an effective training tool for novice surgeons. In neurosurgery, the main fields of the application of virtual endoscopy are third ventriculostomy, endonasal surgery, and the evaluation of pathologies in cerebral blood vessels. Progress in this very active field of research is achieved through cooperation between the technical and the medical communities. While the technology advances and new methods for modeling, reconstruction, and simulation are being developed, clinicians evaluate existing simulators, steer the development of new ones, and explore new fields of application. This review introduces some of the most interesting virtual reality systems for endoscopic neurosurgery developed in recent years and presents clinical studies conducted either on areas of application or specific systems. In addition, benefits and limitations of single products and simulated neuroendoscopy in general are pointed out.

  8. WE-AB-BRA-12: Virtual Endoscope Tracking for Endoscopy-CT Image Registration

    International Nuclear Information System (INIS)

    Ingram, W; Rao, A; Wendt, R; Court, L; Yang, J; Beadle, B

    2015-01-01

    Purpose: The use of endoscopy in radiotherapy will remain limited until we can register endoscopic video to CT using standard clinical equipment. In this phantom study we tested a registration method using virtual endoscopy to measure CT-space positions from endoscopic video. Methods: Our phantom is a contorted clay cylinder with 2-mm-diameter markers in the luminal surface. These markers are visible on both CT and endoscopic video. Virtual endoscope images were rendered from a polygonal mesh created by segmenting the phantom’s luminal surface on CT. We tested registration accuracy by tracking the endoscope’s 6-degree-of-freedom coordinates frame-to-frame in a video recorded as it moved through the phantom, and using these coordinates to measure CT-space positions of markers visible in the final frame. To track the endoscope we used the Nelder-Mead method to search for coordinates that render the virtual frame most similar to the next recorded frame. We measured the endoscope’s initial-frame coordinates using a set of visible markers, and for image similarity we used a combination of mutual information and gradient alignment. CT-space marker positions were measured by projecting their final-frame pixel addresses through the virtual endoscope to intersect with the mesh. Registration error was quantified as the distance between this intersection and the marker’s manually-selected CT-space position. Results: Tracking succeeded for 6 of 8 videos, for which the mean registration error was 4.8±3.5mm (24 measurements total). The mean error in the axial direction (3.1±3.3mm) was larger than in the sagittal or coronal directions (2.0±2.3mm, 1.7±1.6mm). In the other 2 videos, the virtual endoscope got stuck in a false minimum. Conclusion: Our method can successfully track the position and orientation of an endoscope, and it provides accurate spatial mapping from endoscopic video to CT. This method will serve as a foundation for an endoscopy-CT registration

  9. WE-AB-BRA-12: Virtual Endoscope Tracking for Endoscopy-CT Image Registration

    Energy Technology Data Exchange (ETDEWEB)

    Ingram, W; Rao, A; Wendt, R; Court, L [The University of Texas MD Anderson Cancer Center, Houston, TX (United States); The University of Texas Graduate School of Biomedical Sciences, Houston, TX (United States); Yang, J; Beadle, B [The University of Texas MD Anderson Cancer Center, Houston, TX (United States)

    2015-06-15

    Purpose: The use of endoscopy in radiotherapy will remain limited until we can register endoscopic video to CT using standard clinical equipment. In this phantom study we tested a registration method using virtual endoscopy to measure CT-space positions from endoscopic video. Methods: Our phantom is a contorted clay cylinder with 2-mm-diameter markers in the luminal surface. These markers are visible on both CT and endoscopic video. Virtual endoscope images were rendered from a polygonal mesh created by segmenting the phantom’s luminal surface on CT. We tested registration accuracy by tracking the endoscope’s 6-degree-of-freedom coordinates frame-to-frame in a video recorded as it moved through the phantom, and using these coordinates to measure CT-space positions of markers visible in the final frame. To track the endoscope we used the Nelder-Mead method to search for coordinates that render the virtual frame most similar to the next recorded frame. We measured the endoscope’s initial-frame coordinates using a set of visible markers, and for image similarity we used a combination of mutual information and gradient alignment. CT-space marker positions were measured by projecting their final-frame pixel addresses through the virtual endoscope to intersect with the mesh. Registration error was quantified as the distance between this intersection and the marker’s manually-selected CT-space position. Results: Tracking succeeded for 6 of 8 videos, for which the mean registration error was 4.8±3.5mm (24 measurements total). The mean error in the axial direction (3.1±3.3mm) was larger than in the sagittal or coronal directions (2.0±2.3mm, 1.7±1.6mm). In the other 2 videos, the virtual endoscope got stuck in a false minimum. Conclusion: Our method can successfully track the position and orientation of an endoscope, and it provides accurate spatial mapping from endoscopic video to CT. This method will serve as a foundation for an endoscopy-CT registration

  10. Image Based Rendering and Virtual Reality

    DEFF Research Database (Denmark)

    Livatino, Salvatore

    The Presentation concerns with an overview of Image Based Rendering approaches and their use on Virtual Reality, including Virtual Photography and Cinematography, and Mobile Robot Navigation.......The Presentation concerns with an overview of Image Based Rendering approaches and their use on Virtual Reality, including Virtual Photography and Cinematography, and Mobile Robot Navigation....

  11. Hybrid 3D visualization of the chest and virtual endoscopy of the tracheobronchial system: possibilities and limitations of clinical application.

    Science.gov (United States)

    Seemann, M D; Claussen, C D

    2001-06-01

    A hybrid rendering method which combines a color-coded surface rendering method and a volume rendering method is described, which enables virtual endoscopic examinations using different representation models. 14 patients with malignancies of the lung and mediastinum (n=11) and lung transplantation (n=3) underwent thin-section spiral computed tomography. The tracheobronchial system and anatomical and pathological features of the chest were segmented using an interactive threshold interval volume-growing segmentation algorithm and visualized with a color-coded surface rendering method. The structures of interest were then superimposed on a volume rendering of the other thoracic structures. For the virtual endoscopy of the tracheobronchial system, a shaded-surface model without color coding, a transparent color-coded shaded-surface model and a triangle-surface model were tested and compared. The hybrid rendering technique exploit the advantages of both rendering methods, provides an excellent overview of the tracheobronchial system and allows a clear depiction of the complex spatial relationships of anatomical and pathological features. Virtual bronchoscopy with a transparent color-coded shaded-surface model allows both a simultaneous visualization of an airway, an airway lesion and mediastinal structures and a quantitative assessment of the spatial relationship between these structures, thus improving confidence in the diagnosis of endotracheal and endobronchial diseases. Hybrid rendering and virtual endoscopy obviate the need for time consuming detailed analysis and presentation of axial source images. Virtual bronchoscopy with a transparent color-coded shaded-surface model offers a practical alternative to fiberoptic bronchoscopy and is particularly promising for patients in whom fiberoptic bronchoscopy is not feasible, contraindicated or refused. Furthermore, it can be used as a complementary procedure to fiberoptic bronchoscopy in evaluating airway stenosis and

  12. Virtual MRI endoscopy of the intracranial cerebrospinal fluid spaces

    International Nuclear Information System (INIS)

    Shigematsu, Y.; Korogi, Y.; Hirai, T.; Okuda, T.; Ikushima, I.; Sugahara, T.; Liang, L.; Ge, Y.; Takahashi, M.

    1998-01-01

    We used constructive interference in steady state (CISS) 3D Fourier transform (3DFT) MRI data sets to obtain three-dimensional (3D) virtual MRI endoscopic views of the intracranial cerebrospinal fluid (CSF) spaces, processing them with a commercially available perspective endoscopic algorithm. We investigated the potential of the intracranial virtual MRI endoscopy applied to visualisation of the pathology in 13 patients with surgically confirmed trigeminal neuralgia (3), hemifacial spasm (3), acoustic neuroma (3), suprasellar germinoma (1), Langerhans cell histiocytosis (1), lateral ventricle nodules (1) and pituitary dwarfism (1). All images were acquired using a 1.5-T imager employing a circular polarised head coil. The CISS-3DFT data sets were transferred to a workstation for processing with the perspective endoscopic algorithm. Postprocessing for virtual MRI endoscopy was possible for all data sets. The lesions in 12 patients, and their complex anatomical relationships with the surrounding structures, were well seen on the 3D images. A small acoustic neuroma in the internal auditory meatus was not seen using virtual endoscopy. Although virtual MRI endoscopy has limitations, it provides 3D images which cannot be acquired using any other procedure. (orig.)

  13. Virtual MRI endoscopy of the intracranial cerebrospinal fluid spaces

    Energy Technology Data Exchange (ETDEWEB)

    Shigematsu, Y.; Korogi, Y.; Hirai, T. [Kumamoto Univ. (Japan). Dept. of Radiology; Okuda, T.; Ikushima, I.; Sugahara, T.; Liang, L.; Ge, Y.; Takahashi, M.

    1998-10-01

    We used constructive interference in steady state (CISS) 3D Fourier transform (3DFT) MRI data sets to obtain three-dimensional (3D) virtual MRI endoscopic views of the intracranial cerebrospinal fluid (CSF) spaces, processing them with a commercially available perspective endoscopic algorithm. We investigated the potential of the intracranial virtual MRI endoscopy applied to visualisation of the pathology in 13 patients with surgically confirmed trigeminal neuralgia (3), hemifacial spasm (3), acoustic neuroma (3), suprasellar germinoma (1), Langerhans cell histiocytosis (1), lateral ventricle nodules (1) and pituitary dwarfism (1). All images were acquired using a 1.5-T imager employing a circular polarised head coil. The CISS-3DFT data sets were transferred to a workstation for processing with the perspective endoscopic algorithm. Postprocessing for virtual MRI endoscopy was possible for all data sets. The lesions in 12 patients, and their complex anatomical relationships with the surrounding structures, were well seen on the 3D images. A small acoustic neuroma in the internal auditory meatus was not seen using virtual endoscopy. Although virtual MRI endoscopy has limitations, it provides 3D images which cannot be acquired using any other procedure. (orig.) With 6 figs., 16 refs.

  14. [Hybrid 3-D rendering of the thorax and surface-based virtual bronchoscopy in surgical and interventional therapy control].

    Science.gov (United States)

    Seemann, M D; Gebicke, K; Luboldt, W; Albes, J M; Vollmar, J; Schäfer, J F; Beinert, T; Englmeier, K H; Bitzer, M; Claussen, C D

    2001-07-01

    The aim of this study was to demonstrate the possibilities of a hybrid rendering method, the combination of a color-coded surface and volume rendering method, with the feasibility of performing surface-based virtual endoscopy with different representation models in the operative and interventional therapy control of the chest. In 6 consecutive patients with partial lung resection (n = 2) and lung transplantation (n = 4) a thin-section spiral computed tomography of the chest was performed. The tracheobronchial system and the introduced metallic stents were visualized using a color-coded surface rendering method. The remaining thoracic structures were visualized using a volume rendering method. For virtual bronchoscopy, the tracheobronchial system was visualized using a triangle surface model, a shaded-surface model and a transparent shaded-surface model. The hybrid 3D visualization uses the advantages of both the color-coded surface and volume rendering methods and facilitates a clear representation of the tracheobronchial system and the complex topographical relationship of morphological and pathological changes without loss of diagnostic information. Performing virtual bronchoscopy with the transparent shaded-surface model facilitates a reasonable to optimal, simultaneous visualization and assessment of the surface structure of the tracheobronchial system and the surrounding mediastinal structures and lesions. Hybrid rendering relieve the morphological assessment of anatomical and pathological changes without the need for time-consuming detailed analysis and presentation of source images. Performing virtual bronchoscopy with a transparent shaded-surface model offers a promising alternative to flexible fiberoptic bronchoscopy.

  15. CT virtual endoscopy: a study of the capability to display the structures and abnormalities in nasal cavity

    International Nuclear Information System (INIS)

    Han Ping; Brambs, H.J.; Sokiranski, R.

    1999-01-01

    Objective: To evaluate display ability of virtual endoscopy and its clinical application in comparison with fiberoptic nasal endoscopy. Methods: 11 patients (22 nasal cavities) were examined by virtual endoscopy after axial spiral CT scanning was performed. Virtual endoscopy was performed by Explorer software package in a computer workstation. 9 patients (18 nasal cavities) underwent fiberoptic endoscopy. Results: Virtual endoscopy could clearly demonstrate the anatomical structures in nasal cavity, septal deviation, nasal meatus narrowing and obstruction, turbinate hyperplasia, and pathological masses larger than 3 mm in diameter. However, 'false adhesions' may appear in virtual endoscopy. The main limitation of virtual endoscopy was inability to evaluate mucosa and lack of histological diagnosis. Conclusions: Virtual endoscopy is a new, non-invasive method for demonstrating anatomical structures and diseases in nasal cavity. Its display ability is comparable with fiberoptic nasal endoscopy and is a supplement to fiberoptic nasal endoscopy

  16. Evaluation of CT virtual intravascular endoscopy in fenestrated stent grafts: a preliminary study

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Z. [Dept. of Imaging and Applied Physics, Curtin Univ. of Tech., Perth, WA (Australia); Allen, Y.; Fitzsimmons, B.; Hartely, D. [Cook R and D, WA (Australia); Lawrence-Brown, M. [Dept. of Public Health, Curtin Univ. of Tech., Perth, WA (Australia)

    2007-06-15

    We aim in this study to investigate the potential value of CT virtual intravascular endoscopy in patients diagnosed with abdominal aortic aneurysms undergoing fenestrated stent grafts. Both pre-and post-fenestration (within 3 months of implantation) multislice CT data were collected in eight patients and used for generation of virtual endoscopy images in our preliminary study. Variable fenestrations were deployed in 25 aortic branches with scallop fenestration implanted in six aortic ostia, large fenestration in four aortic ostia and small fenestration in 15 renal ostia, respectively. Measurements of the aortic ostia diameters both pre- and post-fenestration were successfully performed with virtual intravascular endoscopy visualization, and endovascular stents as well as their relationship to the aortic ostia were clearly demonstrated. Our results showed that there was no significant change of diameter of the aortic ostia following fenestrated stem grafts. Endovascular stents were clearly visualized on virtual endoscopy images, and no apparent deformity or malrotation was observed in this small group. Our preliminary study provides new insights into anatomic configuration/dimension of aortic ostia and endovascular stents, and virtual intravascular endoscopy could be a valuable technique to follow-up patients treated with fenestrated stent grafts. (orig.)

  17. Evaluation of CT virtual intravascular endoscopy in fenestrated stent grafts: a preliminary study

    International Nuclear Information System (INIS)

    Sun, Z.; Allen, Y.; Fitzsimmons, B.; Hartely, D.; Lawrence-Brown, M.

    2007-01-01

    We aim in this study to investigate the potential value of CT virtual intravascular endoscopy in patients diagnosed with abdominal aortic aneurysms undergoing fenestrated stent grafts. Both pre-and post-fenestration (within 3 months of implantation) multislice CT data were collected in eight patients and used for generation of virtual endoscopy images in our preliminary study. Variable fenestrations were deployed in 25 aortic branches with scallop fenestration implanted in six aortic ostia, large fenestration in four aortic ostia and small fenestration in 15 renal ostia, respectively. Measurements of the aortic ostia diameters both pre- and post-fenestration were successfully performed with virtual intravascular endoscopy visualization, and endovascular stents as well as their relationship to the aortic ostia were clearly demonstrated. Our results showed that there was no significant change of diameter of the aortic ostia following fenestrated stem grafts. Endovascular stents were clearly visualized on virtual endoscopy images, and no apparent deformity or malrotation was observed in this small group. Our preliminary study provides new insights into anatomic configuration/dimension of aortic ostia and endovascular stents, and virtual intravascular endoscopy could be a valuable technique to follow-up patients treated with fenestrated stent grafts. (orig.)

  18. Spiral CT biliary virtual endoscopy: preliminary clinical applications in the detection of biliary calculus

    International Nuclear Information System (INIS)

    Xiong Minghui; Wang Dong; Song Yunlong; Zhang Wanshi; Xu Jiaxing

    2000-01-01

    Objective: To evaluate imaging features and clinical value of CT biliary virtual endoscopy in the detection of biliary calculus. Methods: Eighteen patients with biliary calculi underwent volume scanning using spiral CT (Hispeed Advantage CT/i GE ). All data were transferred to computer workstation, and CT biliary virtual endoscopy images with pseudocolor encoding were generated from the volumetric data using the Navigator Smooth soft-ware. All cases were proved by ultrasound, axial CT or operation. Results: Among 18 cases, gallstones were found 8 in cases, common bile duct stones in 2 cases, gallstones and bile duct stones in 6 cases. The stones were 0.3-3.2 cm in size. CT biliary virtual endoscopy correctly demonstrated the surface details of stones which were viewed from extra- or intraluminal orientation in a 3D fashion. The findings were consistent with those of US, CT or operation. Conclusion: The CT virtual biliary endoscopy is a further development of virtual endoscopy for observing biliary calculus from intra- and extra-luminal views and providing three dimensional information of stone

  19. Virtual reality simulation training for health professions trainees in gastrointestinal endoscopy.

    Science.gov (United States)

    Walsh, Catharine M; Sherlock, Mary E; Ling, Simon C; Carnahan, Heather

    2012-06-13

    Traditionally, training in gastrointestinal endoscopy has been based upon an apprenticeship model, with novice endoscopists learning basic skills under the supervision of experienced preceptors in the clinical setting. Over the last two decades, however, the growing awareness of the need for patient safety has brought the issue of simulation-based training to the forefront. While the use of simulation-based training may have important educational and societal advantages, the effectiveness of virtual reality gastrointestinal endoscopy simulators has yet to be clearly demonstrated. To determine whether virtual reality simulation training can supplement and/or replace early conventional endoscopy training (apprenticeship model) in diagnostic oesophagogastroduodenoscopy, colonoscopy and/or sigmoidoscopy for health professions trainees with limited or no prior endoscopic experience. Health professions, educational and computer databases were searched until November 2011 including The Cochrane Central Register of Controlled Trials, MEDLINE, EMBASE, Scopus, Web of Science, Biosis Previews, CINAHL, Allied and Complementary Medicine Database, ERIC, Education Full Text, CBCA Education, Career and Technical Education @ Scholars Portal, Education Abstracts @ Scholars Portal, Expanded Academic ASAP @ Scholars Portal, ACM Digital Library, IEEE Xplore, Abstracts in New Technologies and Engineering and Computer & Information Systems Abstracts. The grey literature until November 2011 was also searched. Randomised and quasi-randomised clinical trials comparing virtual reality endoscopy (oesophagogastroduodenoscopy, colonoscopy and sigmoidoscopy) simulation training versus any other method of endoscopy training including conventional patient-based training, in-job training, training using another form of endoscopy simulation (e.g. low-fidelity simulator), or no training (however defined by authors) were included.  Trials comparing one method of virtual reality training versus

  20. Virtual endoscopy post-processing of helical CT data sets

    International Nuclear Information System (INIS)

    Dessl, A.; Giacomuzzi, S.M.; Springer, P.; Stoeger, A.; Pototschnig, C.; Voelklein, C.; Schreder, S.G.; Jaschke, W.

    1997-01-01

    Purpose: The purpose of this work was to test a newly developed, post-processing software for virtual CT endoscopic methods. Virtual endoscopic images were generated from helical CT data sets in the region of the shoulder joint (n=2), the tracheobronchial system (n=3), the nasal sinuses (n=2), the colon (n=2), and the common carotid artery (n=1). Software developed specifically for virtual endoscopy ('Navigator') was used which, after a previous threshold value selection, makes the reconstruction of internal body surfaces possible by an automatic segmentation process. We have evaluated the usage of the software, the reconstruction time for individual images and sequences of images as well as the quality of the reconstruction. All pathological findings of the virtual endoscopy were confirmed by surgery. Results: The post-processing program is easy to use and provides virtual endoscopic images within 50 seconds. Depending of the extent of the data set, virtual tracheobronchoscopy as a cine loop sequence required about 15 minutes. Thorugh use of the threshold value-dependent surface reconstruction the demands on the computer configuration are limited; however, this also created quality problems in image calculation as a consequence of the accompanying loss of data. Conclusions: The Navigator software enables the calculation of virtual endoscopic models with only moderate demands on the hardware. (orig.) [de

  1. The effect of virtual endoscopy simulator training on novices: a systematic review.

    Directory of Open Access Journals (Sweden)

    Weiguang Qiao

    Full Text Available BACKGROUND: Advances in virtual endoscopy simulators have paralleled an interest in medical simulation for gastrointestinal endoscopy training. OBJECTIVE: The primary objective was to determine whether the virtual endoscopy simulator training could improve the performance of novices. DESIGN: A systematic review. SETTING: Randomized controlled trials (RCTs that compared virtual endoscopy simulator training with bedside teaching or any other intervention for novices were collected. PATIENTS: Novice endoscopists. INTERVENTIONS: The PRISMA statement was followed during the course of the research. The Cochrane Central Register of Controlled Trials, MEDLINE, EMBASE, and ScienceDirect were searched (up to July 2013. Data extraction and assessment were independently performed. MAIN OUTCOME MEASUREMENTS: Independent procedure completion, total procedure time and required assistance. RESULTS: Fifteen studies (n = 354 were eligible for inclusion: 9 studies designed for colonoscopy training, 6 for gastroscopy training. For gastroscopy training, procedure completed independently was reported in 87.7% of participants in simulator training group compared to 70.0% of participants in control group (1 study; 22 participants; RR 1.25; 95% CI 1.13-1.39; P<0.0001. For colonoscopy training, procedure completed independently was reported in 89.3% of participants in simulator training group compared to 88.9% of participants in control group (7 study; 163 participants; RR 1.10; 95% CI 0.88-1.37; P = 0.41; I(2 = 85%. LIMITATIONS: The included studies are quite in-homogeneous with respect to training schedule and procedure. CONCLUSIONS: Virtual endoscopy simulator training might be effective for gastroscopy, but so far no data is available to support this for colonoscopy.

  2. Preoperative Planning Using 3D Reconstructions and Virtual Endoscopy for Location of the Frontal Sinus

    Directory of Open Access Journals (Sweden)

    Abreu, João Paulo Saraiva

    2011-01-01

    Full Text Available Introduction: Computed tomography (TC generated tridimensional (3D reconstructions allow the observation of cavities and anatomic structures of our body with detail. In our specialty there have been attempts to carry out virtual endoscopies and laryngoscopies. However, such application has been practically abandoned due to its complexity and need for computers with high power of graphic processing. Objective: To demonstrate the production of 3D reconstructions from CTs of patients in personal computers, with a free specific program and compare them to the surgery actual endoscopic images. Method: Prospective study in which the CTs proper files of 10 patients were reconstructed with the program Intage Realia, version 2009, 0, 0, 702 (KGT Inc., Japan. The reconstructions were carried out before the surgeries and a virtual endoscopy was made to assess the recess and frontal sinus region. After this study, the surgery was digitally performed and stored. The actual endoscopic images of the recess and frontal sinus region were compared to the virtual images. Results: The 3D reconstruction and virtual endoscopy were made in 10 patients submitted to the surgery. The virtual images had a large resemblance with the actual surgical images. Conclusion: With relatively simple tools and personal computer, we demonstrated the possibility to generate 3D reconstructions and virtual endoscopies. The preoperative knowledge of the frontal sinus natural draining path location may generate benefits during the performance of surgeries. However, more studies must be developed for the evaluation of the real roles of such 3D reconstructions and virtual endoscopies.

  3. Role of virtual reality simulation in endoscopy training.

    Science.gov (United States)

    Harpham-Lockyer, Louis; Laskaratos, Faidon-Marios; Berlingieri, Pasquale; Epstein, Owen

    2015-12-10

    Recent advancements in virtual reality graphics and models have allowed virtual reality simulators to be incorporated into a variety of endoscopic training programmes. Use of virtual reality simulators in training programmes is thought to improve skill acquisition amongst trainees which is reflected in improved patient comfort and safety. Several studies have already been carried out to ascertain the impact that usage of virtual reality simulators may have upon trainee learning curves and how this may translate to patient comfort. This article reviews the available literature in this area of medical education which is particularly relevant to all parties involved in endoscopy training and curriculum development. Assessment of the available evidence for an optimal exposure time with virtual reality simulators and the long-term benefits of their use are also discussed.

  4. Mucosal detail at CT virtual reality: surface versus volume rendering.

    Science.gov (United States)

    Hopper, K D; Iyriboz, A T; Wise, S W; Neuman, J D; Mauger, D T; Kasales, C J

    2000-02-01

    To evaluate computed tomographic virtual reality with volumetric versus surface rendering. Virtual reality images were reconstructed for 27 normal or pathologic colonic, gastric, or bronchial structures in four ways: the transition zone (a) reconstructed separately from the wall by using volume rendering; (b) with attenuation equal to air; (c) with attenuation equal to wall (soft tissue); (d) with attenuation halfway between air and wall. The four reconstructed images were randomized. Four experienced imagers blinded to the reconstruction graded them from best to worst with predetermined criteria. All readers rated images with the transition zone as a separate structure as overwhelmingly superior (P Virtual reality is best with volume rendering, with the transition zone (mucosa) between the wall and air reconstructed as a separate structure.

  5. Assessment in dogs tympanic bulla, through virtual tomographic endoscopy; Avaliacao de bulas timpanicas em caes, por meio da endoscopia tomografica virtual

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Luciana Carandina da; Sabino, Emanuelle Guidugli, E-mail: lucianacarandina@uol.com.br [Universidade Estadual Paulista Julio de Mesquita Filho (UNESP), Botucatu, SP (Brazil). Faculdade de Medicina Veterinaria. Dept. de Reproducao Animal e Radiologia Veterinaria; Vulcano, Luiz Carlos; Machado, Vania Maria de Vasconcelos [Universidade Estadual Paulista Julio de Mesquita Filho (UNESP), Botucatu, SP (Brazil). Faculdade de Medicina Veterinaria

    2012-07-01

    Dogs usually have problems related to the auditory canal. For the diagnosis of these pathologies, it is necessary a physical examination and, in some cases radiographic examination and computed tomography. The tympanic bulla is not easily visualized radiographically, since there is many structures of the brain overlaying the image obtained. The computed tomography has been the technique of choice to assess this structure faithfully. A new alternative assessment of the tympanic bulla is tomographic virtual endoscopy, which allows an improvement of the image obtained through the virtual tomographic technique. This paper provides information on the use of computed tomography, and a new technique, tomographic virtual endoscopy, in order to make the improvement of these techniques, and prove the reliability of these changes in the diagnosis of ear canals of dogs. Therefore, we performed the computed tomography of the tympanic bulla on healthy animals, and later performed image reconstruction in three-dimensional (3D) mode for virtual endoscopy. (author)

  6. Virtual endoscopy using spiral CT in patients with carcinomas of the hypopharynx and larynx

    International Nuclear Information System (INIS)

    Song, Sang Gook; Seo, Jeong Jin; Chung, Tae Woong; Kim, Hyeong Kil; Jeong, Gwang Woo; Jeong, Yong Yeon; Kang, Heoung Keun; Cho, Jae Sik

    2000-01-01

    To compare the usefulness of virtual endoscopy using spiral CT with that of laryngoscopy in the detection and evaluation of laryngeal and pharyngeal carcinomas. Twenty-four patients with pathologically proven laryngeal and pharyngeal carcinomas underwent laryngoscopy and virtual endoscopy using spiral CT. Eleven of the carcinomas were supraglottic, five were glottic, and eight were hypopharyngeal. Source images obtained by spiral CT were transmitted to an independent workstation and virtual endoscopic images were obtained using Navigator software. These were graded according to their quality (good, fair, bad), and were interpreted by two radiologists who were blinded to the conventional endoscopic findings. These latter were subsequently compared with the virtual endoscopic findings in terms of similarity to laryngoscopic examination and detectability of lesions. The overall image quality of virtual endoscopy was good in 16 cases (67%), fair in eight (33%), and bad in no case. Among the 11 supraglottic carcinomas, image quality was good in seven cases (64%), and fair in four (36%). In four of the five glottic carcinomas (80%) quality was good, and in one case (20%) it was fair, while among the eight hypopharyngeal carcinomas, quality was good in five cases (63%), and fair in three (37%). Overall, detection of the lesion was possible in 23 cases (96%). Due to the small size of the lesion, the one case of glottic carcinoma was not detected. Virtual endoscopy using spiral CT is a safe and noninvasive method, and also successfully detects laryngeal and pharyngeal lesions, with good image quality. For the evaluation of laryngeal and hypopharyngeal carcinoma, its use ma complement that of axial CT. (author)

  7. Application of MR virtual endoscopy in children with hydrocephalus.

    Science.gov (United States)

    Zhao, Cailei; Yang, Jian; Gan, Yungen; Liu, Jiangang; Tan, Zhen; Liang, Guohua; Meng, Xianlei; Sun, Longwei; Cao, Weiguo

    2015-12-01

    To evaluate the performance of MR virtual endoscopy (MRVE) in children with hydrocephalus. Clinical and imaging data were collected from 15 pediatric patients with hydrocephalus and 15 normal control children. All hydrocephalus patients were confirmed by ventriculoscopy or CT imaging. The cranial 3D-T1 weighted imaging data from fast spoiled gradient echo scan (FSPGR) were transported to working station. VE images of cerebral ventricular cavity were constructed with Navigator software. Cerebral ventricular MRVE can achieve similar results as ventriculoscopy in demonstrating the morphology of ventricular wall or intracavity lesion. In addition, MRVE can observe the lesion from distal end of obstruction, as well as other areas that are inaccessible to ventriculoscopy. MRVE can also reveal the pathological change of ventricular inner wall surface, and help determine patency of the cerebral aqueduct and fourth ventricle outlet. MR virtual endoscopy provides a non-invasive diagnostic modality that can be used as a supplemental approach to ventriculoscopy. However, its sensitivity and specificity need to be determined in the large study. Copyright © 2015 Elsevier Inc. All rights reserved.

  8. Development of a virtual speaking simulator using Image Based Rendering.

    Science.gov (United States)

    Lee, J M; Kim, H; Oh, M J; Ku, J H; Jang, D P; Kim, I Y; Kim, S I

    2002-01-01

    The fear of speaking is often cited as the world's most common social phobia. The rapid growth of computer technology has enabled the use of virtual reality (VR) for the treatment of the fear of public speaking. There are two techniques for building virtual environments for the treatment of this fear: a model-based and a movie-based method. Both methods have the weakness that they are unrealistic and not controllable individually. To understand these disadvantages, this paper presents a virtual environment produced with Image Based Rendering (IBR) and a chroma-key simultaneously. IBR enables the creation of realistic virtual environments where the images are stitched panoramically with the photos taken from a digital camera. And the use of chroma-keys puts virtual audience members under individual control in the environment. In addition, real time capture technique is used in constructing the virtual environments enabling spoken interaction between the subject and a therapist or another subject.

  9. Virtual CT-colonoscopy. Examination technique, limitations, and prospects

    International Nuclear Information System (INIS)

    Springer, P.; Dessl, A.; Giacomuzzi, S.M.; Stoehr, B.; Stoeger, A.; Bodner, G.; Buchberger, W.

    1997-01-01

    Virtual CT-colonoscopy is a post-processing method which allows for reconstruction of inner bowel surface structures from helical CT datasets. The reconstructed images simulate the views which are known from fiberoptic endoscopy. Since colorectal cancer is the second main cause of death in USA and Europe today and since recent screening recommendations are often ignored by the public, a non-invasive or minimal-invasive procedure for colonic evaluation would offer some benefits. Virtual CT-colonoscopy generally involves three essential steps: patient preparation with cleansing of the bowel and administration of an air enema, helical CT-examination by using appropriate scan parameters, and interactive 3D rendering of the volume dataset. Although recent studies have demonstrated that polypoid lesions of about 5 mm size are well detectable and although virtual colonoscopy offers many advantages over fiberoptic endoscopy, some technical and clinical limitations must still be noted. Thus, the current inability of virtual colonoscopy to provide texture and color leads to problems in identifying flat lesions; the presence of retained or adherent fecal matter may result to false positive diagnosis and collapsed segments of bowel may cause problems as they cannot subsequently be evaluated during image reconstruction. Virtual endoscopy is still in its infancy and further technical and clinical development are necessary. (orig./AJ) [de

  10. Head and neck computed tomography virtual endoscopy: evaluation of a new imaging technique.

    Science.gov (United States)

    Gallivan, R P; Nguyen, T H; Armstrong, W B

    1999-10-01

    To evaluate a new radiographic imaging technique: computed tomography virtual endoscopy (CTVE) for head and neck tumors. Twenty-one patients presenting with head and neck masses who underwent axial computed tomography (CT) scan with contrast were evaluated by CTVE. Comparisons were made with video-recorded images and operative records to evaluate the potential utility of this new imaging technique. Twenty-one patients with aerodigestive head and neck tumors were evaluated by CTVE. One patient had a nasal cylindrical cell papilloma; the remainder, squamous cell carcinomas distributed throughout the upper aerodigestive tract. Patients underwent complete head and neck examination, flexible laryngoscopy, axial CT with contrast, CTVE, and in most cases, operative endoscopy. Available clinical and radiographic evaluations were compared and correlated to CTVE findings. CTVE accurately demonstrated abnormalities caused by intraluminal tumor, but where there was apposition of normal tissue against tumor, inaccurate depictions of surface contour occurred. Contour resolution was limited, and mucosal irregularity could not be defined. There was very good overall correlation between virtual images, flexible laryngoscopic findings, rigid endoscopy, and operative evaluation in cases where oncological resections were performed. CTVE appears to be most accurate in evaluation of subglottic and nasopharyngeal anatomy in our series of patients. CTVE is a new radiographic technique that provides surface-contour details. The technique is undergoing rapid technical evolution, and although the image quality is limited in situations where there is apposition of tissue folds, there are a number of potential applications for this new imaging technique.

  11. Comparative analysis of video processing and 3D rendering for cloud video games using different virtualization technologies

    Science.gov (United States)

    Bada, Adedayo; Alcaraz-Calero, Jose M.; Wang, Qi; Grecos, Christos

    2014-05-01

    This paper describes a comprehensive empirical performance evaluation of 3D video processing employing the physical/virtual architecture implemented in a cloud environment. Different virtualization technologies, virtual video cards and various 3D benchmarks tools have been utilized in order to analyse the optimal performance in the context of 3D online gaming applications. This study highlights 3D video rendering performance under each type of hypervisors, and other factors including network I/O, disk I/O and memory usage. Comparisons of these factors under well-known virtual display technologies such as VNC, Spice and Virtual 3D adaptors reveal the strengths and weaknesses of the various hypervisors with respect to 3D video rendering and streaming.

  12. Advanced virtual endoscopy for endoscopic transsphenoidal pituitary surgery.

    Science.gov (United States)

    Wolfsberger, Stefan; Neubauer, André; Bühler, Katja; Wegenkittl, Rainer; Czech, Thomas; Gentzsch, Stephan; Böcher-Schwarz, Hans-Gerd; Knosp, Engelbert

    2006-11-01

    Virtual endoscopy (vE) is the navigation of a camera through a virtual anatomical space that is computationally reconstructed from radiological image data. Inside this three-dimensional space, arbitrary movements and adaptations of viewing parameters are possible. Thereby, vE can be used for noninvasive diagnostic purposes and for simulation of surgical tasks. This article describes the development of an advanced system of vE for endoscopic transsphenoidal pituitary surgery and its application to teaching, training, and in the routine clinical setting. The vE system was applied to a series of 35 patients with pituitary pathology (32 adenomas, three Rathke's cleft cysts) operated endoscopically via the transsphenoidal route at the Department of Neurosurgery of the Medical University Vienna between 2004 and 2006. The virtual endoscopic images correlated well with the intraoperative view. For the transsphenoidal approach, vE improved intraoperative orientation by depicting anatomical landmarks and variations. For planning a safe and tailored opening of the sellar floor, transparent visualization of the pituitary adenoma and the normal gland in relation to the internal carotid arteries was useful. According to our experience, vE can be a valuable tool for endoscopic transsphenoidal pituitary surgery for training purposes and preoperative planning. For the novice, it can act as a simulator for endoscopic anatomy and for training surgical tasks. For the experienced pituitary surgeon, vE can depict the individual patient's anatomy, and may, therefore, improve intraoperative orientation. By prospectively visualizing unpredictable anatomical variations, vE may increase the safety of this surgical procedure.

  13. CT virtual intravascular endoscopy assessment of coronary artery plaques: A preliminary study

    International Nuclear Information System (INIS)

    Sun Zhonghua; Dimpudus, Franky Jacobus; Nugroho, Johanes; Adipranoto, Jeffrey Daniel

    2010-01-01

    Purpose: The purpose of this study was to investigate the potential value of CT virtual intravascular endoscopy (VIE) in the visualization and assessment of coronary plaques in patients suspected of coronary artery disease. Materials and methods: 20 (13 men, 7 women, mean age 54 years) consecutive patients with suspected coronary artery disease undergoing 64-slice CT angiography were included in the study. Four main coronary artery branches were assessed with regard to the presence of coronary plaques based on 2D axial, multiplanar reformation, 3D volume rendering and VIE visualizations. The coronary plaques were characterized into calcified, noncalcified and mixed plaques. The intraluminal appearances of these coronary plaques were demonstrated with VIE images and correlated with 2D and 3D images to determine the diagnostic value of VIE for the assessment of the plaques. Results: VIE was able to identify and demonstrate the intraluminal appearances of coronary plaques in 18 patients involving 32 coronary artery branches which were shown as an irregularly intraluminal protruding sign in extensively calcified plaques and smooth protruding appearance in noncalcified or focally calcified plaques. An irregular intraluminal appearance was also noticed in the presence of mixed plaques due to variable components with different CT attenuations contained within the plaques. VIE accurately confirmed the degree of coronary stenosis or occlusion despite the presence of heavy calcification. Conclusion: VIE could be used as a complementary tool to conventional CT visualizations for the analysis of luminal changes and assessment of disease extent caused by the coronary plaques.

  14. Localized intraoperative virtual endoscopy (LIVE) for surgical guidance in 16 skull base patients.

    Science.gov (United States)

    Haerle, Stephan K; Daly, Michael J; Chan, Harley; Vescan, Allan; Witterick, Ian; Gentili, Fred; Zadeh, Gelareh; Kucharczyk, Walter; Irish, Jonathan C

    2015-01-01

    Previous preclinical studies of localized intraoperative virtual endoscopy-image-guided surgery (LIVE-IGS) for skull base surgery suggest a potential clinical benefit. The first aim was to evaluate the registration accuracy of virtual endoscopy based on high-resolution magnetic resonance imaging under clinical conditions. The second aim was to implement and assess real-time proximity alerts for critical structures during skull base drilling. Patients consecutively referred for sinus and skull base surgery were enrolled in this prospective case series. Five patients were used to check registration accuracy and feasibility with the subsequent 11 patients being treated under LIVE-IGS conditions with presentation to the operating surgeon (phase 2). Sixteen skull base patients were endoscopically operated on by using image-based navigation while LIVE-IGS was tested in a clinical setting. Workload was quantitatively assessed using the validated National Aeronautics and Space Administration Task Load Index (NASA-TLX) questionnaire. Real-time localization of the surgical drill was accurate to ~1 to 2 mm in all cases. The use of 3-mm proximity alert zones around the carotid arteries and optic nerve found regular clinical use, as the median minimum distance between the tracked drill and these structures was 1 mm (0.2-3.1 mm) and 0.6 mm (0.2-2.5 mm), respectively. No statistical differences were found in the NASA-TLX indicators for this experienced surgical cohort. Real-time proximity alerts with virtual endoscopic guidance was sufficiently accurate under clinical conditions. Further clinical evaluation is required to evaluate the potential surgical benefits, particularly for less experienced surgeons or for teaching purposes. © American Academy of Otolaryngology—Head and Neck Surgery Foundation 2014.

  15. Virtual Whipple: preoperative surgical planning with volume-rendered MDCT images to identify arterial variants relevant to the Whipple procedure.

    Science.gov (United States)

    Brennan, Darren D; Zamboni, Giulia; Sosna, Jacob; Callery, Mark P; Vollmer, Charles M V; Raptopoulos, Vassilios D; Kruskal, Jonathan B

    2007-05-01

    The purposes of this study were to combine a thorough understanding of the technical aspects of the Whipple procedure with advanced rendering techniques by introducing a virtual Whipple procedure and to evaluate the utility of this new rendering technique in prediction of the arterial variants that cross the anticipated surgical resection plane. The virtual Whipple is a novel technique that follows the complex surgical steps in a Whipple procedure. Three-dimensional reconstructed angiographic images are used to identify arterial variants for the surgeon as part of the preoperative radiologic assessment of pancreatic and ampullary tumors.

  16. A Virtual Reality System for PTCD Simulation Using Direct Visuo-Haptic Rendering of Partially Segmented Image Data.

    Science.gov (United States)

    Fortmeier, Dirk; Mastmeyer, Andre; Schröder, Julian; Handels, Heinz

    2016-01-01

    This study presents a new visuo-haptic virtual reality (VR) training and planning system for percutaneous transhepatic cholangio-drainage (PTCD) based on partially segmented virtual patient models. We only use partially segmented image data instead of a full segmentation and circumvent the necessity of surface or volume mesh models. Haptic interaction with the virtual patient during virtual palpation, ultrasound probing and needle insertion is provided. Furthermore, the VR simulator includes X-ray and ultrasound simulation for image-guided training. The visualization techniques are GPU-accelerated by implementation in Cuda and include real-time volume deformations computed on the grid of the image data. Computation on the image grid enables straightforward integration of the deformed image data into the visualization components. To provide shorter rendering times, the performance of the volume deformation algorithm is improved by a multigrid approach. To evaluate the VR training system, a user evaluation has been performed and deformation algorithms are analyzed in terms of convergence speed with respect to a fully converged solution. The user evaluation shows positive results with increased user confidence after a training session. It is shown that using partially segmented patient data and direct volume rendering is suitable for the simulation of needle insertion procedures such as PTCD.

  17. Virtual endoscopy of the small bowel: phantom study and preliminary clinical results

    International Nuclear Information System (INIS)

    Rogalla, P.; Werner-Rustner, M.; Meiri, N.; Hamm, B.; Huitema, A.; van Est, A.

    1998-01-01

    The purpose of this study was to determine the optimal scanning technique for lesion detection in a small bowel phantom and to evaluate the virtual endoscopy (VE) technique in patients. A small bowel phantom with a fold thickness of 7 mm and length of 115 cm was prepared with nine round lesions (3 x 1 mm, 2 x 2 mm, 2 x 3 mm, 2 x 4 mm). Spiral CT parameters were 7/7/4, 3/5/2, 3/5/1, 1.5/3/1 (slice thickness/table feed/reconstruction interval). VE was done using volume rendering technique with 1 cm distance between images and 120 viewing angle. Two masked readers were asked to determine the number and location of the lesions. Seven patients underwent an abdominal CT during one breathhold after placement of a duodenal tube and filling of the small bowel with methyl cellulose contrast solution. VE images were compared with the axial slices with respect to detectability of pathology. With the 7/7/4 protocol only the 4-mm lesions were visualised with fuzzy contours. The 3/5/2 protocol showed both 4-mm lesions, one 3-mm lesion and one false positive lesion. The 3/5/1 protocol showed both 4-mm and both 3-mm (one uncertain) lesions with improved sharpness, and no false positive lesions. One 2-mm and one 1-mm lesion were additionally seen with the 1.5/3/1 protocol. Path definition was difficult in sharp turns or kinks in the lumen. In all patients, no difference was found between VE and axial slices for bowel pathology; however, axial slices showed 'outside' information that was not included in VE. We conclude that the 3/5/2 protocol may be regarded as an optimal compromise between lesion detection, coverage during one breathhold, and number of reconstructed images in patients; round lesions of 4 mm in diameter can be detected with high certainty. (orig.)

  18. Evaluating progressive-rendering algorithms in appearance design tasks.

    Science.gov (United States)

    Jiawei Ou; Karlik, Ondrej; Křivánek, Jaroslav; Pellacini, Fabio

    2013-01-01

    Progressive rendering is becoming a popular alternative to precomputational approaches to appearance design. However, progressive algorithms create images exhibiting visual artifacts at early stages. A user study investigated these artifacts' effects on user performance in appearance design tasks. Novice and expert subjects performed lighting and material editing tasks with four algorithms: random path tracing, quasirandom path tracing, progressive photon mapping, and virtual-point-light rendering. Both the novices and experts strongly preferred path tracing to progressive photon mapping and virtual-point-light rendering. None of the participants preferred random path tracing to quasirandom path tracing or vice versa; the same situation held between progressive photon mapping and virtual-point-light rendering. The user workflow didn’t differ significantly with the four algorithms. The Web Extras include a video showing how four progressive-rendering algorithms converged (at http://youtu.be/ck-Gevl1e9s), the source code used, and other supplementary materials.

  19. Realistic Real-Time Outdoor Rendering in Augmented Reality

    Science.gov (United States)

    Kolivand, Hoshang; Sunar, Mohd Shahrizal

    2014-01-01

    Realistic rendering techniques of outdoor Augmented Reality (AR) has been an attractive topic since the last two decades considering the sizeable amount of publications in computer graphics. Realistic virtual objects in outdoor rendering AR systems require sophisticated effects such as: shadows, daylight and interactions between sky colours and virtual as well as real objects. A few realistic rendering techniques have been designed to overcome this obstacle, most of which are related to non real-time rendering. However, the problem still remains, especially in outdoor rendering. This paper proposed a much newer, unique technique to achieve realistic real-time outdoor rendering, while taking into account the interaction between sky colours and objects in AR systems with respect to shadows in any specific location, date and time. This approach involves three main phases, which cover different outdoor AR rendering requirements. Firstly, sky colour was generated with respect to the position of the sun. Second step involves the shadow generation algorithm, Z-Partitioning: Gaussian and Fog Shadow Maps (Z-GaF Shadow Maps). Lastly, a technique to integrate sky colours and shadows through its effects on virtual objects in the AR system, is introduced. The experimental results reveal that the proposed technique has significantly improved the realism of real-time outdoor AR rendering, thus solving the problem of realistic AR systems. PMID:25268480

  20. Realistic real-time outdoor rendering in augmented reality.

    Directory of Open Access Journals (Sweden)

    Hoshang Kolivand

    Full Text Available Realistic rendering techniques of outdoor Augmented Reality (AR has been an attractive topic since the last two decades considering the sizeable amount of publications in computer graphics. Realistic virtual objects in outdoor rendering AR systems require sophisticated effects such as: shadows, daylight and interactions between sky colours and virtual as well as real objects. A few realistic rendering techniques have been designed to overcome this obstacle, most of which are related to non real-time rendering. However, the problem still remains, especially in outdoor rendering. This paper proposed a much newer, unique technique to achieve realistic real-time outdoor rendering, while taking into account the interaction between sky colours and objects in AR systems with respect to shadows in any specific location, date and time. This approach involves three main phases, which cover different outdoor AR rendering requirements. Firstly, sky colour was generated with respect to the position of the sun. Second step involves the shadow generation algorithm, Z-Partitioning: Gaussian and Fog Shadow Maps (Z-GaF Shadow Maps. Lastly, a technique to integrate sky colours and shadows through its effects on virtual objects in the AR system, is introduced. The experimental results reveal that the proposed technique has significantly improved the realism of real-time outdoor AR rendering, thus solving the problem of realistic AR systems.

  1. A virtual outpatient department provides a satisfactory patient experience following endoscopy.

    Science.gov (United States)

    Ryan, Elizabeth M; Rogers, Ailín C; Hanly, Ann M; McCawley, Niamh; Deasy, Joseph; McNamara, Deborah A

    2014-03-01

    The purpose of this study was to investigate telephone follow-up of post-endoscopy patients as an alternative to attendance at the outpatient department. Access to outpatient appointments is often a target for improvement in healthcare systems. Increased outpatient clinic capacity is not feasible without investment and extra manpower in an already constrained service. Outpatient attendance was audited at a busy colorectal surgical service. A subset of patients appropriate for follow-up in a "virtual outpatient department" (VOPD) were identified. A pilot study was designed and involved telephone follow-up of low-risk endoscopic procedures. Patient satisfaction was assessed using the Medical Interview Satisfaction Scale (MISS), which is a standardised survey of patient satisfaction with healthcare experiences. This was conducted via anonymous questionnaire at the end of the study. Of a total of 166 patients undergoing endoscopy in the time period, 79 were prospectively recruited to VOPD follow-up based on eligibility criteria. Overall, 67 (84.8 %) were successfully followed up by telephone consultation; nine patients (11.4 %) were contacted by mail. The remaining three patients (3.8 %) were brought back to the OPD. Patients recruited were more likely to be younger (55.82 ± 14.96 versus 60.78 ± 13.97 years, P = 0.029) and to have had normal examinations (49.4 versus 31.0 %, χ (2) = 5.070, P = 0.025). Nearly three quarters of patients responded to the questionnaire. The mean scores for all four aspects of the MISS were satisfactory, and overall patients were satisfied with the VOPD experience. VOPD is a target for improved healthcare provision, with improved efficiency and a high patient satisfaction rate.

  2. Virtual reality system for treatment of the fear of public speaking using image-based rendering and moving pictures.

    Science.gov (United States)

    Lee, Jae M; Ku, Jeong H; Jang, Dong P; Kim, Dong H; Choi, Young H; Kim, In Y; Kim, Sun I

    2002-06-01

    The fear of speaking is often cited as the world's most common social phobia. The rapid growth of computer technology enabled us to use virtual reality (VR) for the treatment of the fear of public speaking. There have been two techniques used to construct a virtual environment for the treatment of the fear of public speaking: model-based and movie-based. Virtual audiences and virtual environments made by model-based technique are unrealistic and unnatural. The movie-based technique has a disadvantage in that each virtual audience cannot be controlled respectively, because all virtual audiences are included in one moving picture file. To address this disadvantage, this paper presents a virtual environment made by using image-based rendering (IBR) and chroma keying simultaneously. IBR enables us to make the virtual environment realistic because the images are stitched panoramically with the photos taken from a digital camera. And the use of chroma keying allows a virtual audience to be controlled individually. In addition, a real-time capture technique was applied in constructing the virtual environment to give the subjects more interaction, in that they can talk with a therapist or another subject.

  3. High definition endoscopy with or without I-Scan increases the detection of celiac disease during routine endoscopy.

    Science.gov (United States)

    Penny, Hugo A; Mooney, Peter D; Burden, Mitchell; Patel, Nisha; Johnston, Alexander J; Wong, Simon H; Teare, Julian; Sanders, David S

    2016-06-01

    Celiac disease remains underdiagnosed at endoscopy. We aimed to assess the utility of I-Scan (virtual chromo-endoscopy) to improve sensitivity of endoscopy to detect markers of villous atrophy in this condition. Patients from 2 UK hospitals were studied in 3 groups. Group 1: standard high definition, white light endoscopy (WLE); Group 2: WLE plus I-Scan; Group 3: non-high definition control group. The presence of endoscopic markers was recorded. At least 4 duodenal biopsies were taken from all patients. Serology was performed concurrently and observations were compared with histology. 758 patients (62% female, mean age 52) were recruited (Group 1: 230; Group 2: 228; Group 3: 300). 135 (17.8%) new diagnoses of coeliac disease were made (21 Group 1; 24 Group 2; 89 Group 3). The sensitivity for detection of endoscopic markers of villous atrophy was significantly higher in both Group 1 (85.7%, p=0.0004) and Group 2 (75%, p=0.005) compared to non-high definition controls (41.6%). There was no significant difference between high definition only and I-Scan groups (p=0.47). In non-high definition endoscopy a missed diagnosis was associated with lesser degrees of villous atrophy (p=0.019) and low tTG titre (p=0.007). High definition endoscopy with or without I-Scan increases the detection of celiac disease during routine endoscopy. Copyright © 2016 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  4. Magnetic resonance angiography virtual endoscopy in the assessment of pulmonary veins before radiofrequency ablation procedures for atrial fibrillation

    Energy Technology Data Exchange (ETDEWEB)

    Cirillo, S.; Tosetti, Irene; Giuseppe, M.De; Longo, M.; Regge, D. [Institute for Cancer Research and Treatment (IRCC), Unit of Radiology, Candiolo (Torino) (Italy); Bonamini, R. [University of Torino, Department of Cardiology, Torino (Italy); Gaita, F.; Bianchi, F.; Vivalda, L. [Ospedale Mauriziano Umberto I, Department of Cardiology, Torino (Italy)

    2004-11-01

    Magnetic resonance angiography (MRA) is a safe and non-invasive imaging method that can readily depict the pulmonary veins (PV), whose imaging has acquired momentum with the advent of new techniques for radiofrequency ablation of atrial fibrillation (AF). We evaluated whether virtual endoscopy from 3D MRA images (MRA-VE) is feasible in studying the morphology of PV. Fifty patients with AF underwent pre-ablative MRA (1.5 T). Images were acquired with axial T-2 weighted and 3D-SPGR sequences after intravenous administration of Gd-DTPA and automatic triggering. Postprocessing was performed by an experienced radiologist with maximum intensity projection (MIP) and virtual endoscopy software (Navigator, GEMS). The venoatrial junction was visualized with MRA-VE in 49 of 50 patients (98.0%). Twenty-seven patients (55.1%) had two ostia on both sides, 13 patients (26.5%) had two ostia on the right and a single common ostium on the left, 5 patients (10.2%) had accessory PV and 4 patients (8.2%) had both an accessory right PV and a single common ostium on the left. Flythrough navigation showed the number and spatial disposition of second-order PV branches in 48 out of 49 patients (98.0%). MRA-VE is an excellent tool for at-a-glance visualization of ostia morphology, navigation of second-generation PV branches and easy endoluminal assessment of left atrial structures in pre-ablative imaging. (orig.)

  5. Magnetic resonance angiography virtual endoscopy in the assessment of pulmonary veins before radiofrequency ablation procedures for atrial fibrillation

    International Nuclear Information System (INIS)

    Cirillo, S.; Tosetti, Irene; Giuseppe, M.De; Longo, M.; Regge, D.; Bonamini, R.; Gaita, F.; Bianchi, F.; Vivalda, L.

    2004-01-01

    Magnetic resonance angiography (MRA) is a safe and non-invasive imaging method that can readily depict the pulmonary veins (PV), whose imaging has acquired momentum with the advent of new techniques for radiofrequency ablation of atrial fibrillation (AF). We evaluated whether virtual endoscopy from 3D MRA images (MRA-VE) is feasible in studying the morphology of PV. Fifty patients with AF underwent pre-ablative MRA (1.5 T). Images were acquired with axial T-2 weighted and 3D-SPGR sequences after intravenous administration of Gd-DTPA and automatic triggering. Postprocessing was performed by an experienced radiologist with maximum intensity projection (MIP) and virtual endoscopy software (Navigator, GEMS). The venoatrial junction was visualized with MRA-VE in 49 of 50 patients (98.0%). Twenty-seven patients (55.1%) had two ostia on both sides, 13 patients (26.5%) had two ostia on the right and a single common ostium on the left, 5 patients (10.2%) had accessory PV and 4 patients (8.2%) had both an accessory right PV and a single common ostium on the left. Flythrough navigation showed the number and spatial disposition of second-order PV branches in 48 out of 49 patients (98.0%). MRA-VE is an excellent tool for at-a-glance visualization of ostia morphology, navigation of second-generation PV branches and easy endoluminal assessment of left atrial structures in pre-ablative imaging. (orig.)

  6. [Virtual CT-pneumocystoscopy: indications, advantages and limitations. Our experience].

    Science.gov (United States)

    Regine, Giovanni; Atzori, Maurizio; Buffa, Vitaliano; Miele, Vittorio; Ialongo, Pasquale; Adami, Loredana

    2003-09-01

    The use of CT volume-rendering techniques allows the evaluation of visceral organs without the need for endoscopy. Conventional endoscopic evaluation of the bladder is limited by the invasiveness of the technique and the difficulty exploring the entire bladder. Virtual evaluation of the bladder by three-dimensional CT reconstruction offers potential advantages and can be used in place of endoscopy. This study investigates the sensitivity of virtual CT in assessing lesion of the bladder wall to compare it with that of conventional endoscopy, and outlines the indications, advantages and disadvantages of virtual CT-pneumocystography. Between September 2001 and May 2002, 21 patients with haematuria and positive cystoscopic findings were studied. After an initial assessment by ultrasound, the patients underwent pelvic CT as a single volumetric scan after preliminary air distension of the bladder by means of 12 F Foley catheter. The images were processed on an independent workstation (Advantage 3.0 GE) running dedicated software for endoluminal navigation. The lesions detected by endoscopy were classified as sessile or pedunculated, and according to size (more or less than 5 mm). Finally, the results obtained at virtual cystoscopy were evaluated by two radiologists blinded to the conventional cystoscopy results. Thirty lesions (24 pedunculated, 6 sessile) were detected at conventional cystoscopy in 16 patients (multiple polyposis in 3 cases). Virtual cystoscopy identified 23 lesions (19 pedunculated and 4 sessile). The undetected lesions were pedunculated <5 mm (5 cases) and sessile (2 cases). One correctly identified pedunculated lesion was associated with a bladder stone. Good quality virtual images were obtained in all of the patients. In only one patient with multiple polyposis the quality of the virtual endoscopic evaluation was limited by the patient's intolerance to bladder distension, although identification of the lesions was not compromised. The overall

  7. Clinical studies on the visualization of gastric lesions using virtual CT endoscopy

    International Nuclear Information System (INIS)

    Kim, Hideki; Takashima, Sumio; Kaminou, Toshio; Hayashi, Seisyo; Nishida, Norifumi; Matsuoka, Toshiyuki; Nakamura, Kenji; Yamada, Ryusaku

    2001-01-01

    We evaluated the clinical usefulness of virtual CT gastro endoscopy (VCTGE). The subjects were 124 patients with endoscopically identified gastric lesions. VCTGE images were obtained using a GE-Navigator. We evaluated VCTGE in the visualization of gastric lesions for their presence and morphology. The detection rate of all gastric lesions by VCTGE was 76% (94 of 124 patients). The smallest detectable early gastric cancer was II c measuring 10 x 8 mm. The detection rates of each gastric lesion by VCTGE were 73% in early gastric cancer, and 90% in advanced gastric cancer. VCTGE imaging in the advanced gastric cancer was good in 12 (30%), fair in 25 (60%) and poor in 4 (10%). VCTGE imaging in early gastric cancer was good in 20 (46%), fair in 12 (27%) and poor in 12 (27%). The significance P level was 0.005 between the evaluation of the imaging of advanced and early gastric cancer. VCTGE visualized the characteristics of diverse gastric lesions and was considered useful for the detection and the diagnosis of these lesions. (author)

  8. Haptic rendering foundations, algorithms, and applications

    CERN Document Server

    Lin, Ming C

    2008-01-01

    For a long time, human beings have dreamed of a virtual world where it is possible to interact with synthetic entities as if they were real. It has been shown that the ability to touch virtual objects increases the sense of presence in virtual environments. This book provides an authoritative overview of state-of-theart haptic rendering algorithms and their applications. The authors examine various approaches and techniques for designing touch-enabled interfaces for a number of applications, including medical training, model design, and maintainability analysis for virtual prototyping, scienti

  9. Preoperative staging of esophageal carcinoma with multidetector CT and virtual endoscopy

    International Nuclear Information System (INIS)

    Onbas, Omer; Eroglu, Atilla; Kantarci, Mecit; Polat, Pinar; Alper, Fatih; Karaoglanoglu, Nurettin; Okur, Adnan

    2006-01-01

    Purpose: The aim of this study was to assess the accuracy of multidetector computed tomography (MDCT), including virtual endoscopy (VE) for detection, precise localization, preoperative evaluation and staging of esophageal cancer (EC) by comparison with surgical and histopathological findings. Materials and methods: Between September 2003 and April 2005, 44 patients with histologically proven EC underwent MDCT and VE. Among 44 patients, the findings were confirmed in 24 at surgery. The accuracy of three-dimensional MDCT for detection, localization, and staging of EC was determined, and compared with surgical finding and histopathology. Results: The overall accuracy of three-dimensional multidetector row CT for detection of EC was 100% (24/24). MDCT staging was correct in 20 patients (83.3%). The T parameter was correctly assessed in 22 (91.7%) cases (understaged in 1 and overstaged in 1). The N parameter was correctly evaluated in 20 (83.4%) patients (understaged in 2 and overstaged in 2). The overall accuracy of VE for the morphologic classification of EC was 81.5%. Conclusions: Three-dimensional MDCT, along with VE is a promising method for preoperative evaluation and staging of EC. Although accuracy in N staging remains low in comparison to PET, it provides a larger amount of diagnostic and staging information

  10. Three-dimensional CT virtual endoscopy in the detection of simulated tumors in a novel phantom bladder and ureter model.

    Science.gov (United States)

    Russell, Shane T; Kawashima, Akira; Vrtiska, Terri J; LeRoy, Andrew J; Bruesewitz, Michael R; Hartman, Robert P; Slezak, Jeffrey M; McCollough, Cynthia H; Chow, George K; King, Bernard F

    2005-03-01

    Cystoscopy and ureteroscopy have limitations in the evaluation for urothelial tumors, and both are invasive. We studied the utility of three-dimensional (3D) CT virtual endoscopy in phantom models. A phantom pelvis was constructed of Plexiglas, porcine pelvic bones, and processed animal fat and scanned at various table speeds in a four detector-row CT machine for ability to detect "tumors" of Solidwater plastic polymer. Images were reconstructed at slice thicknesses of 2.5 to 5.0 mm and reconstructed in 3D for evaluation by two radiologists with no knowledge of the scanning parameters or tumor location. Similar studies were performed with a ureter model. With 5-mm slices, the sensitivity for bladder tumors ranged from 67% for 2-mm tumors to 100% for 4-mm tumors, with 12 false-positive findings. The overall sensitivity was 86% with 3.75-mm slices with one false positive, and with 2.5-mm slices, the sensitivity was 93%, again with one false positive. For the ureteral tumors, the overall sensitivities and numbers of false positives were 88.9% and eight with 5.0-mm collimation, 88.9% and four with 3.75-mm collimation, and 100% and three with 2.5-mm collimation. The effective radiation dose for all studies was equivalent to that of a standard abdomen/pelvis scan. Although virtual endoscopy traditionally has had difficulty detecting tumors <5 mm, the multidetector-row CT protocols used in this study could detect most lesions smaller than this. The scan also depicts the other tissues of the pelvis, which is valuable for staging. The 3D images were produced using data from the CT urogram parameters standard at our institution.

  11. Role of virtual reality simulation in endoscopy training

    OpenAIRE

    Harpham-Lockyer, Louis; Laskaratos, Faidon-Marios; Berlingieri, Pasquale; Epstein, Owen

    2015-01-01

    Recent advancements in virtual reality graphics and models have allowed virtual reality simulators to be incorporated into a variety of endoscopic training programmes. Use of virtual reality simulators in training programmes is thought to improve skill acquisition amongst trainees which is reflected in improved patient comfort and safety. Several studies have already been carried out to ascertain the impact that usage of virtual reality simulators may have upon trainee learning curves and how...

  12. Distributed rendering for multiview parallax displays

    Science.gov (United States)

    Annen, T.; Matusik, W.; Pfister, H.; Seidel, H.-P.; Zwicker, M.

    2006-02-01

    3D display technology holds great promise for the future of television, virtual reality, entertainment, and visualization. Multiview parallax displays deliver stereoscopic views without glasses to arbitrary positions within the viewing zone. These systems must include a high-performance and scalable 3D rendering subsystem in order to generate multiple views at real-time frame rates. This paper describes a distributed rendering system for large-scale multiview parallax displays built with a network of PCs, commodity graphics accelerators, multiple projectors, and multiview screens. The main challenge is to render various perspective views of the scene and assign rendering tasks effectively. In this paper we investigate two different approaches: Optical multiplexing for lenticular screens and software multiplexing for parallax-barrier displays. We describe the construction of large-scale multi-projector 3D display systems using lenticular and parallax-barrier technology. We have developed different distributed rendering algorithms using the Chromium stream-processing framework and evaluate the trade-offs and performance bottlenecks. Our results show that Chromium is well suited for interactive rendering on multiview parallax displays.

  13. Age, Health and Attractiveness Perception of Virtual (Rendered) Human Hair.

    Science.gov (United States)

    Fink, Bernhard; Hufschmidt, Carla; Hirn, Thomas; Will, Susanne; McKelvey, Graham; Lankhof, John

    2016-01-01

    The social significance of physical appearance and beauty has been documented in many studies. It is known that even subtle manipulations of facial morphology and skin condition can alter people's perception of a person's age, health and attractiveness. While the variation in facial morphology and skin condition cues has been studied quite extensively, comparably little is known on the effect of hair on social perception. This has been partly caused by the technical difficulty of creating appropriate stimuli for investigations of people's response to systematic variation of certain hair characteristics, such as color and style, while keeping other features constant. Here, we present a modeling approach to the investigation of human hair perception using computer-generated, virtual (rendered) human hair. In three experiments, we manipulated hair diameter (Experiment 1), hair density (Experiment 2), and hair style (Experiment 3) of human (female) head hair and studied perceptions of age, health and attractiveness. Our results show that even subtle changes in these features have an impact on hair perception. We discuss our findings with reference to previous studies on condition-dependent quality cues in women that influence human social perception, thereby suggesting that hair is a salient feature of human physical appearance, which contributes to the perception of beauty.

  14. Toward real-time virtual biopsy of oral lesions using confocal laser endomicroscopy interfaced with embedded computing.

    Science.gov (United States)

    Thong, Patricia S P; Tandjung, Stephanus S; Movania, Muhammad Mobeen; Chiew, Wei-Ming; Olivo, Malini; Bhuvaneswari, Ramaswamy; Seah, Hock-Soon; Lin, Feng; Qian, Kemao; Soo, Khee-Chee

    2012-05-01

    Oral lesions are conventionally diagnosed using white light endoscopy and histopathology. This can pose a challenge because the lesions may be difficult to visualise under white light illumination. Confocal laser endomicroscopy can be used for confocal fluorescence imaging of surface and subsurface cellular and tissue structures. To move toward real-time "virtual" biopsy of oral lesions, we interfaced an embedded computing system to a confocal laser endomicroscope to achieve a prototype three-dimensional (3-D) fluorescence imaging system. A field-programmable gated array computing platform was programmed to enable synchronization of cross-sectional image grabbing and Z-depth scanning, automate the acquisition of confocal image stacks and perform volume rendering. Fluorescence imaging of the human and murine oral cavities was carried out using the fluorescent dyes fluorescein sodium and hypericin. Volume rendering of cellular and tissue structures from the oral cavity demonstrate the potential of the system for 3-D fluorescence visualization of the oral cavity in real-time. We aim toward achieving a real-time virtual biopsy technique that can complement current diagnostic techniques and aid in targeted biopsy for better clinical outcomes.

  15. Freely-available, true-color volume rendering software and cryohistology data sets for virtual exploration of the temporal bone anatomy.

    Science.gov (United States)

    Kahrs, Lüder Alexander; Labadie, Robert Frederick

    2013-01-01

    Cadaveric dissection of temporal bone anatomy is not always possible or feasible in certain educational environments. Volume rendering using CT and/or MRI helps understanding spatial relationships, but they suffer in nonrealistic depictions especially regarding color of anatomical structures. Freely available, nonstained histological data sets and software which are able to render such data sets in realistic color could overcome this limitation and be a very effective teaching tool. With recent availability of specialized public-domain software, volume rendering of true-color, histological data sets is now possible. We present both feasibility as well as step-by-step instructions to allow processing of publicly available data sets (Visible Female Human and Visible Ear) into easily navigable 3-dimensional models using free software. Example renderings are shown to demonstrate the utility of these free methods in virtual exploration of the complex anatomy of the temporal bone. After exploring the data sets, the Visible Ear appears more natural than the Visible Human. We provide directions for an easy-to-use, open-source software in conjunction with freely available histological data sets. This work facilitates self-education of spatial relationships of anatomical structures inside the human temporal bone as well as it allows exploration of surgical approaches prior to cadaveric testing and/or clinical implementation. Copyright © 2013 S. Karger AG, Basel.

  16. CT virtual endoscopy of the auditory ossicular chain and its preliminary clinical application

    International Nuclear Information System (INIS)

    Wang Dong; Zhang Wanshi; Xiong Minghui; Xu Jiaxing; Yu Min; Xu Changyu

    2000-01-01

    Objective: To evaluate the ability of CT virtual endoscopy (CTVE) in visualization of auditory ossicular chain and its clinical application. Methods: CTVE of auditory ossicular chain was performed on GE HiSpeed CT/i with 1.0 mm slice thickness at pitch 1.0, bone algorithm, 9.6 cm FOV, and 0.1 mm reconstruction interval in 10 normal subjects and 21 patients with middle ear diseases, 14 of them were proved by operation. The threshold values for normal and abnormal auditory ossicular chain were -600--200 HU and 50-300 HU respectively. Results: CTVE could clearly demonstrate the shape, size, and relation of the normal auditory ossicular chain. A visualization rate of malleus, incus, and incudomalleal articulation was 100%, and was 32% for the stapedial foot plate. However, in only 21% could the anterior and posterior crura of stapes be distinguished. Cholesteatoma was found in 12 cases with chronic otitis media, in which CTVE demonstrated varying degrees of destruction of the auditory ossicle. In 1 case with congenital anomaly, ossicle dysplasia was seen. Conclusion: CTVE being a new, non-invasive method for demonstrating the three-dimensional image of auditory ossicular chain is useful in evaluating diseases of the ear, especially the auditory ossicles

  17. Construction and Evaluation of an Ultra Low Latency Frameless Renderer for VR.

    Science.gov (United States)

    Friston, Sebastian; Steed, Anthony; Tilbury, Simon; Gaydadjiev, Georgi

    2016-04-01

    Latency - the delay between a user's action and the response to this action - is known to be detrimental to virtual reality. Latency is typically considered to be a discrete value characterising a delay, constant in time and space - but this characterisation is incomplete. Latency changes across the display during scan-out, and how it does so is dependent on the rendering approach used. In this study, we present an ultra-low latency real-time ray-casting renderer for virtual reality, implemented on an FPGA. Our renderer has a latency of ~1 ms from 'tracker to pixel'. Its frameless nature means that the region of the display with the lowest latency immediately follows the scan-beam. This is in contrast to frame-based systems such as those using typical GPUs, for which the latency increases as scan-out proceeds. Using a series of high and low speed videos of our system in use, we confirm its latency of ~1 ms. We examine how the renderer performs when driving a traditional sequential scan-out display on a readily available HMO, the Oculus Rift OK2. We contrast this with an equivalent apparatus built using a GPU. Using captured human head motion and a set of image quality measures, we assess the ability of these systems to faithfully recreate the stimuli of an ideal virtual reality system - one with a zero latency tracker, renderer and display running at 1 kHz. Finally, we examine the results of these quality measures, and how each rendering approach is affected by velocity of movement and display persistence. We find that our system, with a lower average latency, can more faithfully draw what the ideal virtual reality system would. Further, we find that with low display persistence, the sensitivity to velocity of both systems is lowered, but that it is much lower for ours.

  18. Fast rendering of scanned room geometries

    DEFF Research Database (Denmark)

    Olesen, Søren Krarup; Markovic, Milos; Hammershøi, Dorte

    2014-01-01

    Room acoustics are rendered in Virtual Realities based on models of the real world. These are typically rather coarse representations of the true geometry resulting in room impulse responses with a lack of natural detail. This problem can be overcome by using data scanned by sensors, such as e...

  19. Real-time photorealistic stereoscopic rendering of fire

    Science.gov (United States)

    Rose, Benjamin M.; McAllister, David F.

    2007-02-01

    We propose a method for real-time photorealistic stereo rendering of the natural phenomenon of fire. Applications include the use of virtual reality in fire fighting, military training, and entertainment. Rendering fire in real-time presents a challenge because of the transparency and non-static fluid-like behavior of fire. It is well known that, in general, methods that are effective for monoscopic rendering are not necessarily easily extended to stereo rendering because monoscopic methods often do not provide the depth information necessary to produce the parallax required for binocular disparity in stereoscopic rendering. We investigate the existing techniques used for monoscopic rendering of fire and discuss their suitability for extension to real-time stereo rendering. Methods include the use of precomputed textures, dynamic generation of textures, and rendering models resulting from the approximation of solutions of fluid dynamics equations through the use of ray-tracing algorithms. We have found that in order to attain real-time frame rates, our method based on billboarding is effective. Slicing is used to simulate depth. Texture mapping or 2D images are mapped onto polygons and alpha blending is used to treat transparency. We can use video recordings or prerendered high-quality images of fire as textures to attain photorealistic stereo.

  20. Improving the visual realism of virtual surgery.

    Science.gov (United States)

    Jin, Wei; Lim, Yi-Je; Xu, Xie George; Singh, Tejinder P; De, Suvranu

    2005-01-01

    In this work we focus our attention on improving the visual realism of virtual surgery. A synthetic solution by innovative use of various image-based rendering methods is presented for realistic rendering of virtual surgery scenes. We have, for the first time, developed a methodology for generating virtual surgery scenes with realistic glistening effects by a combination of various image-based rendering techniques, including image mosaicing and view-dependent texture mapping. Realistic examples are presented to showcase the results.

  1. Tactile display for virtual 3D shape rendering

    CERN Document Server

    Mansutti, Alessandro; Bordegoni, Monica; Cugini, Umberto

    2017-01-01

    This book describes a novel system for the simultaneous visual and tactile rendering of product shapes which allows designers to simultaneously touch and see new product shapes during the conceptual phase of product development. This system offers important advantages, including potential cost and time savings, compared with the standard product design process in which digital 3D models and physical prototypes are often repeatedly modified until an optimal design is achieved. The system consists of a tactile display that is able to represent, within a real environment, the shape of a product. Designers can explore the rendered surface by touching curves lying on the product shape, selecting those curves that can be considered style features and evaluating their aesthetic quality. In order to physically represent these selected curves, a flexible surface is modeled by means of servo-actuated modules controlling a physical deforming strip. The tactile display is designed so as to be portable, low cost, modular,...

  2. Democratizing rendering for multiple viewers in surround VR systems

    KAUST Repository

    Schulze, Jü rgen P.; Acevedo-Feliz, Daniel; Mangan, John; Prudhomme, Andrew; Nguyen, Phi Khanh; Weber, Philip P.

    2012-01-01

    We present a new approach for how multiple users' views can be rendered in a surround virtual environment without using special multi-view hardware. It is based on the idea that different parts of the screen are often viewed by different users, so that they can be rendered from their own view point, or at least from a point closer to their view point than traditionally expected. The vast majority of 3D virtual reality systems are designed for one head-tracked user, and a number of passive viewers. Only the head tracked user gets to see the correct view of the scene, everybody else sees a distorted image. We reduce this problem by algorithmically democratizing the rendering view point among all tracked users. Researchers have proposed solutions for multiple tracked users, but most of them require major changes to the display hardware of the VR system, such as additional projectors or custom VR glasses. Our approach does not require additional hardware, except the ability to track each participating user. We propose three versions of our multi-viewer algorithm. Each of them balances image distortion and frame rate in different ways, making them more or less suitable for certain application scenarios. Our most sophisticated algorithm renders each pixel from its own, optimized camera perspective, which depends on all tracked users' head positions and orientations. © 2012 IEEE.

  3. Democratizing rendering for multiple viewers in surround VR systems

    KAUST Repository

    Schulze, Jürgen P.

    2012-03-01

    We present a new approach for how multiple users\\' views can be rendered in a surround virtual environment without using special multi-view hardware. It is based on the idea that different parts of the screen are often viewed by different users, so that they can be rendered from their own view point, or at least from a point closer to their view point than traditionally expected. The vast majority of 3D virtual reality systems are designed for one head-tracked user, and a number of passive viewers. Only the head tracked user gets to see the correct view of the scene, everybody else sees a distorted image. We reduce this problem by algorithmically democratizing the rendering view point among all tracked users. Researchers have proposed solutions for multiple tracked users, but most of them require major changes to the display hardware of the VR system, such as additional projectors or custom VR glasses. Our approach does not require additional hardware, except the ability to track each participating user. We propose three versions of our multi-viewer algorithm. Each of them balances image distortion and frame rate in different ways, making them more or less suitable for certain application scenarios. Our most sophisticated algorithm renders each pixel from its own, optimized camera perspective, which depends on all tracked users\\' head positions and orientations. © 2012 IEEE.

  4. Capsule Endoscopy

    Science.gov (United States)

    ... because experience with it is limited and traditional upper endoscopy is widely available. Why it's done Your doctor might recommend a capsule endoscopy procedure to: Find the cause of gastrointestinal bleeding. If you have unexplained bleeding in your digestive ...

  5. Robotics in endoscopy.

    Science.gov (United States)

    Klibansky, David; Rothstein, Richard I

    2012-09-01

    The increasing complexity of intralumenal and emerging translumenal endoscopic procedures has created an opportunity to apply robotics in endoscopy. Computer-assisted or direct-drive robotic technology allows the triangulation of flexible tools through telemanipulation. The creation of new flexible operative platforms, along with other emerging technology such as nanobots and steerable capsules, can be transformational for endoscopic procedures. In this review, we cover some background information on the use of robotics in surgery and endoscopy, and review the emerging literature on platforms, capsules, and mini-robotic units. The development of techniques in advanced intralumenal endoscopy (endoscopic mucosal resection and endoscopic submucosal dissection) and translumenal endoscopic procedures (NOTES) has generated a number of novel platforms, flexible tools, and devices that can apply robotic principles to endoscopy. The development of a fully flexible endoscopic surgical toolkit will enable increasingly advanced procedures to be performed through natural orifices. The application of platforms and new flexible tools to the areas of advanced endoscopy and NOTES heralds the opportunity to employ useful robotic technology. Following the examples of the utility of robotics from the field of laparoscopic surgery, we can anticipate the emerging role of robotic technology in endoscopy.

  6. Virtual Acoustics: Evaluation of Psychoacoustic Parameters

    Science.gov (United States)

    Begault, Durand R.; Null, Cynthia H. (Technical Monitor)

    1997-01-01

    Current virtual acoustic displays for teleconferencing and virtual reality are usually limited to very simple or non-existent renderings of reverberation, a fundamental part of the acoustic environmental context that is encountered in day-to-day hearing. Several research efforts have produced results that suggest that environmental cues dramatically improve perceptual performance within virtual acoustic displays, and that is possible to manipulate signal processing parameters to effectively reproduce important aspects of virtual acoustic perception in real-time. However, the computational resources for rendering reverberation remain formidable. Our efforts at NASA Ames have been focused using a several perceptual threshold metrics, to determine how various "trade-offs" might be made in real-time acoustic rendering. This includes both original work and confirmation of existing data that was obtained in real rather than virtual environments. The talk will consider the importance of using individualized versus generalized pinnae cues (the "Head-Related Transfer Function"); the use of head movement cues; threshold data for early reflections and late reverberation; and consideration of the necessary accuracy for measuring and rendering octave-band absorption characteristics of various wall surfaces. In addition, a consideration of the analysis-synthesis of the reverberation within "everyday spaces" (offices, conference rooms) will be contrasted to the commonly used paradigm of concert hall spaces.

  7. The effect of depth compression on multiview rendering quality

    NARCIS (Netherlands)

    Merkle, P.; Morvan, Y.; Smolic, A.; Farin, D.S.; Mueller, K..; With, de P.H.N.; Wiegand, T.

    2010-01-01

    This paper presents a comparative study on different techniques for depth-image compression and its implications on the quality of multiview video plus depth virtual view rendering. A novel coding algorithm for depth images that concentrates on their special characteristics, namely smooth regions

  8. Endoscopy in pregnancy.

    LENUS (Irish Health Repository)

    O'mahony, Seamus

    2012-02-03

    Endoscopy is rarely required during pregnancy. The potential risks of endoscopy during pregnancy include foetal hypoxia due to sedative drugs and exposure to radiation. There is no evidence that endoscopy precipitates premature labour, and studies in this area have concluded that endoscopy during pregnancy is generally safe. There should be a strong indication for the procedure, which should be deferred whenever possible to the second trimester. Procedures should be performed without any sedation, or with the lowest dose of sedative medication. Radiation exposure should be kept to a minimum. Support should be obtained from specialists in obstetrics and anaesthesia. Indications for endoscopy during pregnancy are as follows: (1) gastroscopy: upper gastrointestinal bleeding, dysphagia, uncontrolled nausea\\/vomiting; (2) sigmoidoscopy\\/colonoscopy: rectal bleeding, diarrhoea; and (3) ERCP: choledocholithiasis, biliary pancreatitis. Sedative drugs, such as midazolam appear to be safe if used carefully. Radiation exposure during ERCP can be kept well below the danger level for teratogenicity.

  9. Continuous Surface Rendering, Passing from CAD to Physical Representation

    Directory of Open Access Journals (Sweden)

    Mario Covarrubias

    2013-06-01

    Full Text Available This paper describes a desktop-mechatronic interface that has been conceived to support designers in the evaluation of aesthetic virtual shapes. This device allows a continuous and smooth free hand contact interaction on a real and developable plastic tape actuated by a servo-controlled mechanism. The objective in designing this device is to reproduce a virtual surface with a consistent physical rendering well adapted to designers' needs. The desktop-mechatronic interface consists in a servo-actuated plastic strip that has been devised and implemented using seven interpolation points. In fact, by using the MEC (Minimal Energy Curve Spline approach, a developable real surface is rendered taking into account the CAD geometry of the virtual shapes. In this paper, we describe the working principles of the interface by using both absolute and relative approaches to control the position on each single control point on the MEC spline. Then, we describe the methodology that has been implemented, passing from the CAD geometry, linked to VisualNastran in order to maintain the parametric properties of the virtual shape. Then, we present the co-simulation between VisualNastran and MATLAB/Simulink used for achieving this goal and controlling the system and finally, we present the results of the subsequent testing session specifically carried out to evaluate the accuracy and the effectiveness of the mechatronic device.

  10. Virtual reality for spherical images

    Science.gov (United States)

    Pilarczyk, Rafal; Skarbek, Władysław

    2017-08-01

    Paper presents virtual reality application framework and application concept for mobile devices. Framework uses Google Cardboard library for Android operating system. Framework allows to create virtual reality 360 video player using standard OpenGL ES rendering methods. Framework provides network methods in order to connect to web server as application resource provider. Resources are delivered using JSON response as result of HTTP requests. Web server also uses Socket.IO library for synchronous communication between application and server. Framework implements methods to create event driven process of rendering additional content based on video timestamp and virtual reality head point of view.

  11. Technical endoscopy

    International Nuclear Information System (INIS)

    Cavalar, K.O.

    1988-01-01

    A survey is provided on different versions of endoscopes, taking into account the new developments of video endoscopy. With a variety of practical examples it is shown that technical tests using endoscopy are a demanding task for nondestructive testing, whose requirements can only be met on a customized basis. (orig./HP) [de

  12. European Society of Gastrointestinal Endoscopy - Establishing the key unanswered research questions within gastrointestinal endoscopy

    DEFF Research Database (Denmark)

    Rees, Colin J; Ngu, Wee Sing; Regula, Jaroslaw

    2016-01-01

    Background and study aim: Gastrointestinal endoscopy is a rapidly evolving research field. The European Society of Gastrointestinal Endoscopy (ESGE) plays a key role in shaping opinion and endoscopy activity throughout Europe and further afield. Establishing key unanswered questions within the fi...

  13. The Application of Hemospray in Gastrointestinal Bleeding during Emergency Endoscopy

    Directory of Open Access Journals (Sweden)

    Alexander F. Hagel

    2017-01-01

    Full Text Available Introduction. Gastrointestinal bleeding represents the main indication for emergency endoscopy (EE. Lately, several hemostatic powders have been released to facilitate EE. Methods. We evaluated all EE in which Hemospray was used as primary or salvage therapy, with regard to short- and long-term hemostasis and complications. Results. We conducted 677 EE in 474 patients (488 examinations in 344 patients were upper GI endoscopies. Hemospray was applied during 35 examinations in 27 patients (19 males, 33 during upper and 2 during lower endoscopy. It was used after previous treatment in 21 examinations (60% and in 14 (40% as salvage therapy. Short-term success was reached in 34 of 35 applications (97.1%, while long-term success occurred in 23 applications (65.7%. Similar long-term results were found after primary application (64,3% or salvage therapy (66,7%. Rebleeding was found in malignant and extended ulcers. One major adverse event (2.8% occurred with gastric perforation after Hemospray application. Discussion. Hemospray achieved short-term hemostasis in virtually all cases. The long-term effect is mainly determined by the type of bleeding source, but not whether it was applied as first line or salvage therapy. But, even in the failures, patients had benefit from hemodynamic stabilization and consecutive interventions in optimized conditions.

  14. Matching rendered and real world images by digital image processing

    Science.gov (United States)

    Mitjà, Carles; Bover, Toni; Bigas, Miquel; Escofet, Jaume

    2010-05-01

    Recent advances in computer-generated images (CGI) have been used in commercial and industrial photography providing a broad scope in product advertising. Mixing real world images with those rendered from virtual space software shows a more or less visible mismatching between corresponding image quality performance. Rendered images are produced by software which quality performance is only limited by the resolution output. Real world images are taken with cameras with some amount of image degradation factors as lens residual aberrations, diffraction, sensor low pass anti aliasing filters, color pattern demosaicing, etc. The effect of all those image quality degradation factors can be characterized by the system Point Spread Function (PSF). Because the image is the convolution of the object by the system PSF, its characterization shows the amount of image degradation added to any taken picture. This work explores the use of image processing to degrade the rendered images following the parameters indicated by the real system PSF, attempting to match both virtual and real world image qualities. The system MTF is determined by the slanted edge method both in laboratory conditions and in the real picture environment in order to compare the influence of the working conditions on the device performance; an approximation to the system PSF is derived from the two measurements. The rendered images are filtered through a Gaussian filter obtained from the taking system PSF. Results with and without filtering are shown and compared measuring the contrast achieved in different final image regions.

  15. Utility of capsule endoscopy for evaluating anthelmintic efficacy in fully conscious dogs.

    Science.gov (United States)

    Lee, Alice C Y; Epe, Christian; Simpson, Kenneth W; Bowman, Dwight D

    2011-11-01

    The current accepted standard for evaluating the efficacy of gastrointestinal anthelmintic drugs is necropsy of infected animals followed by a comparison of worm counts between treated and non-treated groups. In this study capsule endoscopy, a minimally invasive method of imaging the small intestine of humans, is evaluated as a possible alternative to necropsy for the purposes of worm quantification in dogs. Eighteen Beagle dogs were included in this study. These dogs were part of a separate trial intended to determine the efficacy of various candidate parasiticides against Ancylostoma caninum via the necropsy standard. Dogs were inoculated with A. caninum L3s 4 weeks prior to treatment with one of the candidate compounds; a control group (n=8) received no treatment. Capsule endoscopy was performed 6-14 days post-treatment, followed by necropsy the following day. Seventeen dogs had complete examinations, i.e. the capsule traversed the small intestine and reached the colon within the battery life of the capsule. A strong correlation (r(s)=0.87, Pcapsule endoscopy and necropsy. There was no clear relationship between the ability of the capsule endoscope to detect hookworms and either visibility of the intestinal lumen or small intestinal transit time. Generation of a virtual spatial record of hookworm location from the capsule endoscopy data revealed a temporal trend, with the majority of worms present in the proximal small intestine in the morning versus the central to distal small intestine in the afternoon. Worm distribution as determined by capsule endoscopy closely resembled post-mortem findings. In conclusion, capsule endoscopy shows promise as an alternative to necropsy for the enumeration of A. caninum in the canine small intestine, although further work is required to improve completion rates and optimise intestinal examination. Copyright © 2011 Australian Society for Parasitology Inc. Published by Elsevier Ltd. All rights reserved.

  16. Single minimum incision endoscopic radical nephrectomy for renal tumors with preoperative virtual navigation using 3D-CT volume-rendering

    Directory of Open Access Journals (Sweden)

    Shioyama Yasukazu

    2010-04-01

    Full Text Available Abstract Background Single minimum incision endoscopic surgery (MIES involves the use of a flexible high-definition laparoscope to facilitate open surgery. We reviewed our method of radical nephrectomy for renal tumors, which is single MIES combined with preoperative virtual surgery employing three-dimensional CT images reconstructed by the volume rendering method (3D-CT images in order to safely and appropriately approach the renal hilar vessels. We also assessed the usefulness of 3D-CT images. Methods Radical nephrectomy was done by single MIES via the translumbar approach in 80 consecutive patients. We performed the initial 20 MIES nephrectomies without preoperative 3D-CT images and the subsequent 60 MIES nephrectomies with preoperative 3D-CT images for evaluation of the renal hilar vessels and the relation of each tumor to the surrounding structures. On the basis of the 3D information, preoperative virtual surgery was performed with a computer. Results Single MIES nephrectomy was successful in all patients. In the 60 patients who underwent 3D-CT, the number of renal arteries and veins corresponded exactly with the preoperative 3D-CT data (100% sensitivity and 100% specificity. These 60 nephrectomies were completed with a shorter operating time and smaller blood loss than the initial 20 nephrectomies. Conclusions Single MIES radical nephrectomy combined with 3D-CT and virtual surgery achieved a shorter operating time and less blood loss, possibly due to safer and easier handling of the renal hilar vessels.

  17. Diagnostic potential of virtual bronchoscopy: advantages in comparison with axial CT slices, MPR and mIP?

    International Nuclear Information System (INIS)

    Rapp-Bernhardt, U.; Doehring, W.; Bernhardt, T.M.; Welte, T.; Kropf, S.

    2000-01-01

    The aim of this study was to evaluate the diagnostic potential of virtual endoscopy (VE) and to compare it with axial CT slices, multiplanar reconstructions (MPR), minimal intensity projections (mIP), and bronchoscopy in patients diagnosed with bronchogenic carcinoma. Thirty patients underwent a spiral CT. Axial CT images were transferred to an Onyx workstation (Silicon Graphics, Sun Microsystems, Mountain View, Calif.) for performing virtual endoscopy. Accuracy for this procedure was tested by three radiologists on a monitor in comparison with axial CT slices, MPR, mIP, and bronchoscopy concerning the localization and degree of stenoses. Endoluminal tumors were identified by virtual bronchoscopy with no statistically significant difference of localization or grading of stenosis in comparison with bronchoscopy, axial CT slices, MPR and mIP. Axial CT slices, MPR, and mIP showed poorer results with over- or underestimation of stenoses compared with VE and bronchoscopy. Passing of stenoses was only possible with VE in 5 patients. Virtual endoscopy is a non-invasive method for identification of endoluminal tumors and is comparable to real bronchoscopy. (orig.)

  18. Diagnostic potential of virtual bronchoscopy: advantages in comparison with axial CT slices, MPR and mIP?

    Energy Technology Data Exchange (ETDEWEB)

    Rapp-Bernhardt, U.; Doehring, W.; Bernhardt, T.M. [Department of Diagnostic Radiology, Otto-von-Guericke University, Magdeburg (Germany); Welte, T. [Department of Cardiology, Angiology, and Pneumology, Otto-von-Guericke University, Magdeburg (Germany); Kropf, S. [Department of Biometrics and Medical Informatics, Otto-von-Guericke University, Magdeburg (Germany)

    2000-06-01

    The aim of this study was to evaluate the diagnostic potential of virtual endoscopy (VE) and to compare it with axial CT slices, multiplanar reconstructions (MPR), minimal intensity projections (mIP), and bronchoscopy in patients diagnosed with bronchogenic carcinoma. Thirty patients underwent a spiral CT. Axial CT images were transferred to an Onyx workstation (Silicon Graphics, Sun Microsystems, Mountain View, Calif.) for performing virtual endoscopy. Accuracy for this procedure was tested by three radiologists on a monitor in comparison with axial CT slices, MPR, mIP, and bronchoscopy concerning the localization and degree of stenoses. Endoluminal tumors were identified by virtual bronchoscopy with no statistically significant difference of localization or grading of stenosis in comparison with bronchoscopy, axial CT slices, MPR and mIP. Axial CT slices, MPR, and mIP showed poorer results with over- or underestimation of stenoses compared with VE and bronchoscopy. Passing of stenoses was only possible with VE in 5 patients. Virtual endoscopy is a non-invasive method for identification of endoluminal tumors and is comparable to real bronchoscopy. (orig.)

  19. Virtual Reality and Simulation in Neurosurgical Training.

    Science.gov (United States)

    Bernardo, Antonio

    2017-10-01

    Recent biotechnological advances, including three-dimensional microscopy and endoscopy, virtual reality, surgical simulation, surgical robotics, and advanced neuroimaging, have continued to mold the surgeon-computer relationship. For developing neurosurgeons, such tools can reduce the learning curve, improve conceptual understanding of complex anatomy, and enhance visuospatial skills. We explore the current and future roles and application of virtual reality and simulation in neurosurgical training. Copyright © 2017 Elsevier Inc. All rights reserved.

  20. Immersive virtual walk-through development for tokamak using active head mounted display

    International Nuclear Information System (INIS)

    Dutta, Pramit

    2015-01-01

    A fully immersive virtual walk-through of the SST-1 tokamak has been developed. The virtual walkthrough renders the virtual model of SST-1 tokamak through a active stereoscopic head mounted display to visualize the virtual environment. All locations inside and outside of the reactor can be accessed and reviewed. Such a virtual walkthrough provides a 1:1 scale visualization of all components of the tokamak. To achieve such a virtual model, the graphical details of the tokamak CAD model are enhanced. Such enhancements are provided to improve lighting conditions at various locations, texturing of components to have a realistic visual effect and 360° rendering for ease of access. The graphical enhancements also include the redefinition of the facets to optimize the surface triangles to remove lags in display during visual rendering. Two separate algorithms are developed to interact with the virtual model. A fly-by algorithm, developed using C#, uses inputs from a commercial joystick to navigate within the virtual environment. The second algorithm uses the IR and gyroscopic tracking system of the head mounted display to render view as per the current pose of the user within the virtual environment and the direction of view. Such a virtual walk-thorough can be used extensively for design review and integration, review of new components, operator training for remote handling, operations, upgrades of tokamak, etc. (author)

  1. Relationships of virtual reality neuroendoscopic simulations to actual imaging.

    Science.gov (United States)

    Riegel, T; Alberti, O; Retsch, R; Shiratori, V; Hellwig, D; Bertalanffy, H

    2000-12-01

    Advances in computer technology have permitted virtual reality images of the ventricular system. To determine the relevance of these images we have compared virtual reality simulations of the ventricular system with endoscopic findings in three patients. The virtual fly-through can be simulated after definition of waypoints. Flight objects of interest can be viewed from all sides. Important drawbacks are that filigree structures may be missed and blood vessels cannot be distinguished clearly. However, virtual endoscopy can presently be used as a planning tool or for training and has future potential for neurosurgery.

  2. Risk Management for Gastrointestinal Endoscopy in Elderly Patients: Questionnaire for Patients Undergoing Gastrointestinal Endoscopy

    OpenAIRE

    Umegaki, Eiji; Abe, Shinya; Tokioka, Satoshi; Takeuchi, Nozomi; Takeuchi, Toshihisa; Yoda, Yukiko; Murano, Mitsuyuki; Higuchi, Kazuhide

    2009-01-01

    More elderly patients now undergo gastrointestinal endoscopy following recent advances in endoscopic techniques. In this study, we conducted a high-risk survey of endoscopies in Japan, using a questionnaire administered prior to upper gastrointestinal tract endoscopy (UGITE), and identified anticholinergic agents and glucagon preparations as high-risk premedication. We also evaluated the cardiovascular effects of anticholinergic agents and glucagon through measurements of plasma levels of hum...

  3. Virtual gastroscopy using spiral CT in gastric lesions

    International Nuclear Information System (INIS)

    Shin, Sang Soo; Kang, Heoung Keun; Jeong, Yong Yeon; Yoon, Man Won; Song, Sang Gook; Jeong, Gwang Woo

    1998-01-01

    To compare virtual gastroscopy using spiral CT with conventional endoscopy for the detection and evaluation of gastric lesions. During a previous six-month period, 30 patients with pathologically-proven gastric lesions underwent conventional endoscopy and virtual gastroscopy using spiral CT. There were 18 cases of advanced gastric carcinoma, eight benign ulcers, and four submucosal tumors(two leiomyomas, two lymphomas). Source images of virtual gastroscopy were three-dim-ensionally reconstructed within an Advantage Windows Workstation and virtual gastroscopic images were obtained using Navigator Software. On analysis, images were graded according to their quality(excellent, good, poor). Virtual gastroscopic images were interpreted by two radiologists blinded to conventional endoscopic findings, and were subsequently compared with endoscopic findings in terms of detectability and findings. In the cases of advanced gastric carcinoma, lesions were classified according to Borrmann's system. For virtual gastroscopy, overall image quality was excellent in 21 cases(70%), good in five(17%), and poor in four(13%). Lesions were detected in 25 cases(83%). Among the 18 advanced gastric carcinomas, virtual gastroscopy image quality was excellent in 14 cases(78%), good in two(11%), and poor in two(11%). Lesions were detected in 16 cases(89%). Two Borrmann type IV cases were not detected. Among the eight benign ulcers, virtual gastroscopy image quality was excellent in three cases(38%), good in three(38%), and poor in two(25%). The detection of lesion was possible in five cases(63%). In all submucosal tumors, virtual gastroscopy image quality was excellent. Lesions were detected in all cases. Virtual gastroscopy using spiral CT is safe and noninvasive, and for the evaluation of gastric lesions may be complementary to axial CT. It successfully detects gastric lesions, and in depicting the pattern of gastric folds its image quality is excellent.=20

  4. A point-based rendering approach for real-time interaction on mobile devices

    Institute of Scientific and Technical Information of China (English)

    LIANG XiaoHui; ZHAO QinPing; HE ZhiYing; XIE Ke; LIU YuBo

    2009-01-01

    Mobile device is an Important interactive platform. Due to the limitation of computation, memory, display area and energy, how to realize the efficient and real-time interaction of 3D models based on mobile devices is an important research topic. Considering features of mobile devices, this paper adopts remote rendering mode and point models, and then, proposes a transmission and rendering approach that could interact in real time. First, improved simplification algorithm based on MLS and display resolution of mobile devices is proposed. Then, a hierarchy selection of point models and a QoS transmission control strategy are given based on interest area of operator, interest degree of object in the virtual environment and rendering error. They can save the energy consumption. Finally, the rendering and interaction of point models are completed on mobile devices. The experiments show that our method is efficient.

  5. Quality Improvement in Pediatric Endoscopy: A Clinical Report From the NASPGHAN Endoscopy Committee.

    Science.gov (United States)

    Kramer, Robert E; Walsh, Catharine M; Lerner, Diana G; Fishman, Douglas S

    2017-07-01

    The current era of healthcare reform emphasizes the provision of effective, safe, equitable, high-quality, and cost-effective care. Within the realm of gastrointestinal endoscopy in adults, renewed efforts are in place to accurately define and measure quality indicators across the spectrum of endoscopic care. In pediatrics, however, this movement has been less-defined and lacks much of the evidence-base that supports these initiatives in adult care. A need, therefore, exists to help define quality metrics tailored to pediatric practice and provide a toolbox for the development of robust quality improvement (QI) programs within pediatric endoscopy units. Use of uniform standards of quality reporting across centers will ensure that data can be compared and compiled on an international level to help guide QI initiatives and inform patients and their caregivers of the true risks and benefits of endoscopy. This report is intended to provide pediatric gastroenterologists with a framework for the development and implementation of endoscopy QI programs within their own centers, based on available evidence and expert opinion from the members of the NASPGHAN Endoscopy Committee. This clinical report will require expansion as further research pertaining to endoscopic quality in pediatrics is published.

  6. Real-Time 3D Motion capture by monocular vision and virtual rendering

    OpenAIRE

    Gomez Jauregui , David Antonio; Horain , Patrick

    2012-01-01

    International audience; Avatars in networked 3D virtual environments allow users to interact over the Internet and to get some feeling of virtual telepresence. However, avatar control may be tedious. Motion capture systems based on 3D sensors have recently reached the consumer market, but webcams and camera-phones are more widespread and cheaper. The proposed demonstration aims at animating a user's avatar from real time 3D motion capture by monoscopic computer vision, thus allowing virtual t...

  7. Reporting systems in gastrointestinal endoscopy: Requirements and standards facilitating quality improvement: European Society of Gastrointestinal Endoscopy position statement

    NARCIS (Netherlands)

    Bretthauer, Michael; Aabakken, Lars; Dekker, Evelien; Kaminski, Michal F.; Rösch, Thomas; Hultcrantz, Rolf; Suchanek, Stepan; Jover, Rodrigo; Kuipers, Ernst J.; Bisschops, Raf; Spada, Cristiano; Valori, Roland; Domagk, Dirk; Rees, Colin; Rutter, Matthew D.

    2016-01-01

    To develop standards for high quality of gastrointestinal endoscopy, the European Society of Gastrointestinal Endoscopy (ESGE) has established the ESGE Quality Improvement Committee. A prerequisite for quality assurance and improvement for all gastrointestinal endoscopy procedures is

  8. Visualizing dynamic geosciences phenomena using an octree-based view-dependent LOD strategy within virtual globes

    Science.gov (United States)

    Li, Jing; Wu, Huayi; Yang, Chaowei; Wong, David W.; Xie, Jibo

    2011-09-01

    Geoscientists build dynamic models to simulate various natural phenomena for a better understanding of our planet. Interactive visualizations of these geoscience models and their outputs through virtual globes on the Internet can help the public understand the dynamic phenomena related to the Earth more intuitively. However, challenges arise when the volume of four-dimensional data (4D), 3D in space plus time, is huge for rendering. Datasets loaded from geographically distributed data servers require synchronization between ingesting and rendering data. Also the visualization capability of display clients varies significantly in such an online visualization environment; some may not have high-end graphic cards. To enhance the efficiency of visualizing dynamic volumetric data in virtual globes, this paper proposes a systematic framework, in which an octree-based multiresolution data structure is implemented to organize time series 3D geospatial data to be used in virtual globe environments. This framework includes a view-dependent continuous level of detail (LOD) strategy formulated as a synchronized part of the virtual globe rendering process. Through the octree-based data retrieval process, the LOD strategy enables the rendering of the 4D simulation at a consistent and acceptable frame rate. To demonstrate the capabilities of this framework, data of a simulated dust storm event are rendered in World Wind, an open source virtual globe. The rendering performances with and without the octree-based LOD strategy are compared. The experimental results show that using the proposed data structure and processing strategy significantly enhances the visualization performance when rendering dynamic geospatial phenomena in virtual globes.

  9. Dual-focus Magnification, High-Definition Endoscopy Improves Pathology Detection in Direct-to-Test Diagnostic Upper Gastrointestinal Endoscopy.

    Science.gov (United States)

    Bond, Ashley; Burkitt, Michael D; Cox, Trevor; Smart, Howard L; Probert, Chris; Haslam, Neil; Sarkar, Sanchoy

    2017-03-01

    In the UK, the majority of diagnostic upper gastrointestinal (UGI) endoscopies are a result of direct-to-test referral from the primary care physician. The diagnostic yield of these tests is relatively low, and the burden high on endoscopy services. Dual-focus magnification, high-definition endoscopy is expected to improve detection and classification of UGI mucosal lesions and also help minimize biopsies by allowing better targeting. This is a retrospective study of patients attending for direct-to-test UGI endoscopy from January 2015 to June 2015. The primary outcome of interest was the identification of significant pathology. Detection of significant pathology was modelled using logistic regression. 500 procedures were included. The mean age of patients was 61.5 (±15.6) years; 60.8% of patients were female. Ninety-four gastroscopies were performed using dual-focus magnification high-definition endoscopy. Increasing age, male gender, type of endoscope, and type of operator were all identified as significant factors influencing the odds of detecting significant mucosal pathology. Use of dual-focus magnification, high-definition endoscopy was associated with an odds ratio of 1.87 (95%CI 1.11-3.12) favouring the detection of significant pathology. Subsequent analysis suggested that the increased detection of pathology during dual-focus magnification, high-definition endoscopy also influenced patient follow-up and led to a 3.0 fold (p=0.04) increase in the proportion of patients entered into an UGI endoscopic surveillance program. Dual-focus magnification, high-definition endoscopy improved the diagnostic yield for significant mucosal pathology in patients referred for direct-to-test endoscopy. If this finding is recapitulated elsewhere it will have substantial impact on the provision of UGI endoscopic services.

  10. Parallel rendering

    Science.gov (United States)

    Crockett, Thomas W.

    1995-01-01

    This article provides a broad introduction to the subject of parallel rendering, encompassing both hardware and software systems. The focus is on the underlying concepts and the issues which arise in the design of parallel rendering algorithms and systems. We examine the different types of parallelism and how they can be applied in rendering applications. Concepts from parallel computing, such as data decomposition, task granularity, scalability, and load balancing, are considered in relation to the rendering problem. We also explore concepts from computer graphics, such as coherence and projection, which have a significant impact on the structure of parallel rendering algorithms. Our survey covers a number of practical considerations as well, including the choice of architectural platform, communication and memory requirements, and the problem of image assembly and display. We illustrate the discussion with numerous examples from the parallel rendering literature, representing most of the principal rendering methods currently used in computer graphics.

  11. Three-dimensional motion tracking correlates with skill level in upper gastrointestinal endoscopy

    DEFF Research Database (Denmark)

    Arnold, Sif H.; Svendsen, Morten Bo Søndergaard; Konge, Lars

    2015-01-01

    untrained medical students) were tested using a virtual reality simulator. A motion sensor was used to collect data regarding the distance between the hands, and height and movement of the scope hand. Test characteristics between groups were explored using Kruskal-Wallis H and Man-Whitney U exact tests......Background and study aim: Feedback is an essential part of training in upper gastrointestinal endoscopy. Virtual reality simulators provide limited feedback, focusing only on visual recognition with no feedback on the procedural part of training. Motion tracking identifies patterns of movement......, and this study aimed to explore the correlation between skill level and operator movement using an objective automated tool. Methods: In this medical education study, 37 operators (12 senior doctors who performed endoscopic retrograde cholangiopancreatography, 13 doctors with varying levels of experience, and 12...

  12. Virtual laryngoscopy-preliminary experience

    Energy Technology Data Exchange (ETDEWEB)

    Byrne, A.T. [Departments of Radiology, Adelaide and Meath Hospital, Dublin 24 (Ireland); Walshe, P. [Departments of Otolaryngology, Adelaide and Meath Hospital, Dublin 24 (Ireland); McShane, D. [Departments of Otolaryngology, Adelaide and Meath Hospital, Dublin 24 (Ireland); Hamilton, S. [Departments of Radiology, Adelaide and Meath Hospital, Dublin 24 (Ireland)]. E-mail: samuel.hamilton@amnch.ie

    2005-10-01

    Purpose: Computed tomographic virtual laryngoscopy is a non-invasive radiological technique that allows visualisation of intra-luminal surfaces by three-dimensional reconstruction of air/soft tissue interfaces. It is particularly useful when the patient cannot tolerate clinical examination, when infection, neoplasm or congenital defects compromise the lumen and for assessment of the sub-glottic region. We have performed virtual laryngoscopy on patients referred because of upper airway symptoms, and compared the findings with those at conventional laryngoscopy. Materials and methods: Axial scans were obtained using a Toshiba Xpress helical scanner. Virtual laryngoscopy was then performed on a workstation using Toshiba 'Fly-thru' software and was completed within 5 min. Results: Pathology included vocal cord nodules, laryngeal cysts, Reinke's oedema, laryngeal neoplasms and leukoplakia. Conclusions: Virtual laryngoscopy displays anatomical detail comparable to conventional endoscopy. Impassable obstructions are no hindrance and all viewing directions are possible. It is especially useful for providing views of the larynx from below.

  13. Three-dimensional rendering of segmented object using matlab - biomed 2010.

    Science.gov (United States)

    Anderson, Jeffrey R; Barrett, Steven F

    2010-01-01

    The three-dimensional rendering of microscopic objects is a difficult and challenging task that often requires specialized image processing techniques. Previous work has been described of a semi-automatic segmentation process of fluorescently stained neurons collected as a sequence of slice images with a confocal laser scanning microscope. Once properly segmented, each individual object can be rendered and studied as a three-dimensional virtual object. This paper describes the work associated with the design and development of Matlab files to create three-dimensional images from the segmented object data previously mentioned. Part of the motivation for this work is to integrate both the segmentation and rendering processes into one software application, providing a seamless transition from the segmentation tasks to the rendering and visualization tasks. Previously these tasks were accomplished on two different computer systems, windows and Linux. This transition basically limits the usefulness of the segmentation and rendering applications to those who have both computer systems readily available. The focus of this work is to create custom Matlab image processing algorithms for object rendering and visualization, and merge these capabilities to the Matlab files that were developed especially for the image segmentation task. The completed Matlab application will contain both the segmentation and rendering processes in a single graphical user interface, or GUI. This process for rendering three-dimensional images in Matlab requires that a sequence of two-dimensional binary images, representing a cross-sectional slice of the object, be reassembled in a 3D space, and covered with a surface. Additional segmented objects can be rendered in the same 3D space. The surface properties of each object can be varied by the user to aid in the study and analysis of the objects. This inter-active process becomes a powerful visual tool to study and understand microscopic objects.

  14. Anesthesia related Complications in Pediatric GI Endoscopy

    Directory of Open Access Journals (Sweden)

    A Sabzevari

    2014-04-01

    Full Text Available Introduction: Elective upper and lower GI endoscopy is usually performed in children on an outpatient basis with the child under sedation or general anesthesia (GA. The objective of this study was to describe Anesthesia related complications in   children undergoing elective GI endoscopy.   Materials and Methods: The study design was descriptive on 1388 patients undergoing elective GI endoscopy in Sheikh Hospital from 2009 to 2013. All patient received propofol or standard inhalational anesthesia. We examined patients’ demographic data  ,  location of GI endoscopy ,  perioperative vital singe ,  recovery time , respiratory and cardiac complications , post operative nausea and vomiting , agitation , diagnosis and outcome   Results: Pediatric patients aged 2 to 17 years. 29 % of elective GI endoscopy was upper GI endoscopy and 70.3 % was lower GI endoscopy and 0.7 was both of them. 47.7 % of Pediatric patients were female and 52.3 % was male. We haven’t significant or fatal anesthesia related respiratory and cardiac complications (no apnea, no cardiac arrest. 8 patients (0.5% have transient bradicardia in post operative care Unit. 83 patients (5.9% have post operative nausea and vomiting controlled by medication.  6 patients (0.4% have post operative agitation controlled by medication.   Conclusions: General anesthesia and deep sedation in children undergoing elective GI endoscopy haven’t significant or fatal anesthesia related complications. We suggest Anesthesia for infants, young children, children with neurologic impairment, and some anxious older children undergoing elective GI endoscopy. Keyword: Anesthesia, Complication, Endoscopy, Pediatric.

  15. INCREASING SAVING BEHAVIOR THROUGH AGE-PROGRESSED RENDERINGS OF THE FUTURE SELF

    Science.gov (United States)

    HERSHFIELD, HAL E.; GOLDSTEIN, DANIEL G.; SHARPE, WILLIAM F.; FOX, JESSE; YEYKELIS, LEO; CARSTENSEN, LAURA L.; BAILENSON, JEREMY N.

    2014-01-01

    Many people fail to save what they need to for retirement (Munnell, Webb, and Golub-Sass 2009). Research on excessive discounting of the future suggests that removing the lure of immediate rewards by pre-committing to decisions, or elaborating the value of future rewards can both make decisions more future-oriented. In this article, we explore a third and complementary route, one that deals not with present and future rewards, but with present and future selves. In line with thinkers who have suggested that people may fail, through a lack of belief or imagination, to identify with their future selves (Parfit 1971; Schelling 1984), we propose that allowing people to interact with age-progressed renderings of themselves will cause them to allocate more resources toward the future. In four studies, participants interacted with realistic computer renderings of their future selves using immersive virtual reality hardware and interactive decision aids. In all cases, those who interacted with virtual future selves exhibited an increased tendency to accept later monetary rewards over immediate ones. PMID:24634544

  16. INCREASING SAVING BEHAVIOR THROUGH AGE-PROGRESSED RENDERINGS OF THE FUTURE SELF.

    Science.gov (United States)

    Hershfield, Hal E; Goldstein, Daniel G; Sharpe, William F; Fox, Jesse; Yeykelis, Leo; Carstensen, Laura L; Bailenson, Jeremy N

    2011-11-01

    Many people fail to save what they need to for retirement (Munnell, Webb, and Golub-Sass 2009). Research on excessive discounting of the future suggests that removing the lure of immediate rewards by pre-committing to decisions, or elaborating the value of future rewards can both make decisions more future-oriented. In this article, we explore a third and complementary route, one that deals not with present and future rewards, but with present and future selves. In line with thinkers who have suggested that people may fail, through a lack of belief or imagination, to identify with their future selves (Parfit 1971; Schelling 1984), we propose that allowing people to interact with age-progressed renderings of themselves will cause them to allocate more resources toward the future. In four studies, participants interacted with realistic computer renderings of their future selves using immersive virtual reality hardware and interactive decision aids. In all cases, those who interacted with virtual future selves exhibited an increased tendency to accept later monetary rewards over immediate ones.

  17. Virtual endoscopy combined with intraoperative neuronavigation for planning of endoscopic surgery in patients with occlusive hydrocephalus and intracranial cysts

    International Nuclear Information System (INIS)

    Krombach, G.A.; Haage, P.; Kilbinger, M.; Rohde, V.; Struffert, T.; Thron, A.

    2002-01-01

    We assessed the clinical value of MR ventriculoscopy (virtual endoscopy, VE) combined with image-guided frameless stereotaxy for endoscopic surgery of occlusive hydrocephalus and intracranial cysts. VE was obtained in 20 patients with hydrocephalus and three with intracranial cysts. All surgical operations were endoscopic. The path of the rigid endoscope to the target point was planned using neuronavigation. VE was carried out along the same trajectory retrospectively in 20 cases and prospectively in three. The results were analysed for demonstration of anatomical landmarks and structures at risk. VE was successful in all patients. Possible obstacles to endoscopic access to the lamina terminalis and the basal cisterns and structures at risk, such as the basilar artery, were clearly shown in relation to the direction of the endoscope. However, the floor of the third ventricle and septum pellucidum were not clearly seen and possible abnormalities could therefore not be appreciated. VE can provide realistic simulation of endoscopic third ventriculostomy and cystostomy. The appropriate trepanation point and trajectory of the endoscope can be assessed with regard to the size of the foramen of Monro and the position of vulnerable structures. This simulated trajectory can be adapted to the field of operation by image-guided neuronavigation. This regime may potentially reduce the risk of damage to intracranial structures. (orig.)

  18. How to Improve the Quality of Screening Endoscopy in Korea: National Endoscopy Quality Improvement Program.

    Science.gov (United States)

    Cho, Yu Kyung

    2016-07-01

    In Korea, gastric cancer screening, either esophagogastroduodenoscopy or upper gastrointestinal series (UGIS), is performed biennially for adults aged 40 years or older. Screening endoscopy has been shown to be associated with localized cancer detection and better than UGIS. However, the diagnostic sensitivity of detecting cancer is not satisfactory. The National Endoscopy Quality Improvement (QI) program was initiated in 2009 to enhance the quality of medical institutions and improve the effectiveness of the National Cancer Screening Program (NCSP). The Korean Society of Gastrointestinal Endoscopy developed quality standards through a broad systematic review of other endoscopic quality guidelines and discussions with experts. The standards comprise five domains: qualifications of endoscopists, endoscopic unit facilities and equipment, endoscopic procedure, endoscopy outcomes, and endoscopic reprocessing. After 5 years of the QI program, feedback surveys showed that the perception of QI and endoscopic practice improved substantially in all domains of quality, but the quality standards need to be revised. How to avoid missing cancer in endoscopic procedures in daily practice was reviewed, which can be applied to the mass screening endoscopy. To improve the quality and effectiveness of NCSP, key performance indicators, acceptable quality standards, regular audit, and appropriate reimbursement are necessary.

  19. in upper gastrointestinal endoscopy

    Directory of Open Access Journals (Sweden)

    Sinan Uzman

    2016-07-01

    Full Text Available Introduction : There is increasing interest in sedation for upper gastrointestinal endoscopy (UGE. Prospective randomized studies comparing sedation properties and complications of propofol and midazolam/meperidine in upper gastrointestinal endoscopy (UGE are few. Aim: To compare propofol and midazolam/meperidine sedation for UGE in terms of cardiopulmonary side effects, patient and endoscopist satisfaction and procedure-related times. Material and methods: This was a prospective, randomized, double-blind study of propofol versus midazolam and meperidine in 100 patients scheduled for diagnostic upper gastrointestinal endoscopy. The patients were divided into propofol and midazolam/meperidine groups. Randomization was generated by a computer. Cardiopulmonary side effects (hypotension, bradycardia, hypoxemia, procedure-related times (endoscopy time, awake time, time to hospital discharge, and patient and endoscopist satisfaction were compared between groups. Results: There was no significant difference between the groups with respect to the cost, endoscopy time, or demographic and clinical characteristics of the patients. Awake time and time to hospital discharge were significantly shorter in the propofol group (6.58 ±4.72 vs. 9.32 ±4.26 min, p = 0.030 and 27.60 ±7.88 vs. 32.00 ±10.54 min, p = 0.019. Hypotension incidence was significantly higher in the propofol group (12% vs. 0%, p = 0.027. The patient and endoscopist satisfaction was better with propofol. Conclusions : Propofol may be preferred to midazolam/meperidine sedation, with a shorter awake and hospital discharge time and better patient and endoscopist satisfaction. However, hypotension risk should be considered with propofol, and careful evaluation is needed, particularly in cardiopulmonary disorders.

  20. A Feasibility Study with Image-Based Rendered Virtual Reality in Patients with Mild Cognitive Impairment and Dementia.

    Directory of Open Access Journals (Sweden)

    Valeria Manera

    Full Text Available Virtual Reality (VR has emerged as a promising tool in many domains of therapy and rehabilitation, and has recently attracted the attention of researchers and clinicians working with elderly people with MCI, Alzheimer's disease and related disorders. Here we present a study testing the feasibility of using highly realistic image-based rendered VR with patients with MCI and dementia. We designed an attentional task to train selective and sustained attention, and we tested a VR and a paper version of this task in a single-session within-subjects design. Results showed that participants with MCI and dementia reported to be highly satisfied and interested in the task, and they reported high feelings of security, low discomfort, anxiety and fatigue. In addition, participants reported a preference for the VR condition compared to the paper condition, even if the task was more difficult. Interestingly, apathetic participants showed a preference for the VR condition stronger than that of non-apathetic participants. These findings suggest that VR-based training can be considered as an interesting tool to improve adherence to cognitive training in elderly people with cognitive impairment.

  1. Prediction of Helicobacter pylori status by conventional endoscopy, narrow-band imaging magnifying endoscopy in stomach after endoscopic resection of gastric cancer.

    Science.gov (United States)

    Yagi, Kazuyoshi; Saka, Akiko; Nozawa, Yujiro; Nakamura, Atsuo

    2014-04-01

    To reduce the incidence of metachronous gastric carcinoma after endoscopic resection of early gastric cancer, Helicobacter pylori eradication therapy has been endorsed. It is not unusual for such patients to be H. pylori negative after eradication or for other reasons. If it were possible to predict H. pylori status using endoscopy alone, it would be very useful in clinical practice. To clarify the accuracy of endoscopic judgment of H. pylori status, we evaluated it in the stomach after endoscopic submucosal dissection (ESD) of gastric cancer. Fifty-six patients treated by ESD were enrolled. The diagnostic criteria for H. pylori status by conventional endoscopy and narrow-band imaging (NBI)-magnifying endoscopy were decided, and H. pylori status was judged by two endoscopists. Based on the H. pylori stool antigen test as a diagnostic gold standard, conventional endoscopy and NBI-magnifying endoscopy were compared for their sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV). Interobserver agreement was assessed in terms of κ value. Interobserver agreement was moderate (0.56) for conventional endoscopy and substantial (0.77) for NBI-magnifying endoscopy. The sensitivity, specificity, PPV, and NPV were 0.79, 0.52, 0.70, and 0.63 for conventional endoscopy and 0.91, 0.83, 0.88, and 0.86 for NBI-magnifying endoscopy, respectively. Prediction of H. pylori status using NBI-magnifying endoscopy is practical, and interobserver agreement is substantial. © 2013 John Wiley & Sons Ltd.

  2. Development of Virtual Reality Cycling Simulator

    OpenAIRE

    Schramka, Filip; Arisona, Stefan; Joos, Michael; Erath, Alexander

    2017-01-01

    This paper presents a cycling simulator implemented using consumer virtual reality hardware and additional off-the-shelf sensors. Challenges like real time motion tracking within the performance requirements of state of the art virtual reality are successfully mastered. Retrieved data from digital motion processors is sent over Bluetooth to a render machine running Unity3D. By processing this data a bicycle is mapped into virtual space. Physically correct behaviour is simulated and high quali...

  3. The feasibility of endoscopy-CT image registration in the head and neck without prospective endoscope tracking.

    Directory of Open Access Journals (Sweden)

    W Scott Ingram

    Full Text Available Endoscopic examinations are frequently-used procedures for patients with head and neck cancer undergoing radiotherapy, but radiation treatment plans are created on computed tomography (CT scans. Image registration between endoscopic video and CT could be used to improve treatment planning and analysis of radiation-related normal tissue toxicity. The purpose of this study was to explore the feasibility of endoscopy-CT image registration without prospective physical tracking of the endoscope during the examination.A novel registration technique called Location Search was developed. This technique uses physical constraints on the endoscope's view direction to search for the virtual endoscope coordinates that maximize the similarity between the endoscopic video frame and the virtual endoscopic image. Its performance was tested on phantom and patient images and compared to an established registration technique, Frame-To-Frame Tracking.In phantoms, Location Search had average registration errors of 0.55 ± 0.60 cm for point measurements and 0.29 ± 0.15 cm for object surface measurements. Frame-To-Frame Tracking achieved similar results on some frames, but it failed on others due to the virtual endoscope becoming lost. This weakness was more pronounced in patients, where Frame-To-Frame tracking could not make it through the nasal cavity. On successful patient video frames, Location Search was able to find endoscope positions with an average distance of 0.98 ± 0.53 cm away from the ground truth positions. However, it failed on many frames due to false similarity matches caused by anatomical structural differences between the endoscopic video and the virtual endoscopic images.Endoscopy-CT image registration without prospective physical tracking of the endoscope is possible, but more development is required to achieve an accuracy suitable for clinical translation.

  4. Requirements and standards facilitating quality improvement for reporting systems in gastrointestinal endoscopy: European Society of Gastrointestinal Endoscopy (ESGE) Position Statement

    NARCIS (Netherlands)

    Bretthauer, Michael; Aabakken, Lars; Dekker, Evelien; Kaminski, Michal F.; Rösch, Thomas; Hultcrantz, Rolf; Suchanek, Stepan; Jover, Rodrigo; Kuipers, Ernst J.; Bisschops, Raf; Spada, Cristiano; Valori, Roland; Domagk, Dirk; Rees, Colin; Rutter, Matthew D.

    2016-01-01

    To develop standards for high quality in gastrointestinal (GI) endoscopy, the European Society of Gastrointestinal Endoscopy (ESGE) has established the ESGE Quality Improvement Committee. A prerequisite for quality assurance and improvement for all GI endoscopy procedures is state-of-the-art

  5. Leadership and team building in gastrointestinal endoscopy.

    Science.gov (United States)

    Valori, Roland M; Johnston, Deborah J

    2016-06-01

    A modern endoscopy service delivers high volume procedures that can be daunting, embarrassing and uncomfortable for patients [1]. Endoscopy is hugely beneficial to patients but only if it is performed to high standards [2]. Some consequences of poor quality endoscopy include worse outcomes for cancer and gastrointestinal bleeding, unnecessary repeat procedures, needless damage to patients and even avoidable death [3]. New endoscopy technology and more rigorous decontamination procedures have made endoscopy more effective and safer, but they have placed additional demands on the service. Ever-scarcer resources require more efficient, higher turnover of patients, which can be at odds with a good patient experience, and with quality and safety. It is clear from the demands put upon it, that to deliver a modern endoscopy service requires effective leadership and team working [4]. This chapter explores what constitutes effective leadership and what makes great clinical teams. It makes the point that endoscopy services are not usually isolated, independent units, and as such are dependent for success on the organisations they sit within. It will explain how endoscopy services are affected by the wider policy and governance context. Finally, within the context of the collection of papers in this edition of Best Practice & Research: Clinical Gastroenterology, it explores the potentially conflicting relationship between training of endoscopists and service delivery. The effectiveness of leadership and teams is rarely the subject of classic experimental designs such as randomized controlled trials. Nevertheless there is a substantial literature on this subject within and particularly outside healthcare [5]. The authors draw on this wider, more diffuse literature and on their experience of delivering a Team Leadership Programme (TLP) to the leaders of 70 endoscopy teams during the period 2008-2012. (Team Leadership Programme Link

  6. Endoscopy in Canada: Proceedings of the National Roundtable

    Directory of Open Access Journals (Sweden)

    Noah Switzer

    2015-01-01

    Full Text Available This 2014 roundtable discussion, hosted by the Canadian Association of General Surgeons, brought together general surgeons and gastroenterologists with expertise in endoscopy from across Canada to discuss the state of endoscopy in Canada. The focus of the roundtable was the evaluation of the competence of general surgeons at endoscopy, reviewing quality assurance parameters for high-quality endoscopy, measuring and assessing surgical resident preparedness for endoscopy practice, evaluating credentialing programs for the endosuite and predicting the future of endoscopic services in Canada. The roundtable noted several important observations. There exist inadequacies in both resident training and the assessment of competency in endoscopy. From these observations, several collaborative recommendations were then stated. These included the need for a formal and standardized system of both accreditation and training endoscopists.

  7. Virtual chromoendoscopy can be a useful software tool in capsule endoscopy La Cromoendoscopia virtual puede ser una herramienta de software útil en la cápsula endoscópica

    Directory of Open Access Journals (Sweden)

    Gabriela Duque

    2012-05-01

    Full Text Available Background: capsule endoscopy (CE has revolutionized the study of small bowel. One major drawback of this technique is that we cannot interfere with image acquisition process. Therefore, the development of new software tools that could modify the images and increase both detection and diagnosis of small-bowel lesions would be very useful. The Flexible Spectral Imaging Color Enhancement (FICE that allows for virtual chromoendoscopy is one of these software tools. Aims: to evaluate the reproducibility and diagnostic accuracy of the FICE system in CE. Methods: this prospective study involved 20 patients. First, four physicians interpreted 150 static FICE images and the overall agree-ment between them was determined using the Fleiss Kappa Test. Second, two experienced gastroenterologists, blinded to each other results, analyzed the complete 20 video streams. One interpreted conventional capsule videos and the other, the CE-FICE videos at setting 2. All findings were reported, regardless of their clinical value. Non-concordant findings between both interpretations were analyzed by a consensus panel of four gastroenterologists who reached a final result (positive or negative finding. Results: in the first arm of the study the overall concordance between the four gastroenterologists was substantial (0.650. In the second arm, the conventional mode identified 75 findings and the CE-FICE mode 95. The CE-FICE mode did not miss any lesions identified by the conventional mode and allowed the identification of a higher number of angiodysplasias (35 vs 32, and erosions (41 vs. 24. Conclusions: there is reproducibility for the interpretation of CE-FICE images between different observers experienced in conventional CE. The use of virtual chromoendoscopy in CE seems to increase its diagnostic accuracy by highlighting small bowel erosions and angiodysplasias that weren't identified by the conventional mode.

  8. Virtual endoscopy of the upper urinary tract based on contrast material-enhanced MR urography data sets; Virtuelle Endoskopie des oberen Harntraktes auf der Basis kontrastangehobener MR-Urographie Datensaetze

    Energy Technology Data Exchange (ETDEWEB)

    Nolte-Ernsting, C.C.A.; Krombach, G.; Staatz, G.; Kilbinger, M.; Adam, G.B.; Guenther, R.W. [RWTH Aachen (Germany). Klinik fuer Radiologische Diagnostik

    1999-06-01

    Purpose: To investigate the feasibility of reconstructing a virtual endoscopy from MR imaging data sets of the upper urinary tract. Method: The data obtained from 28 contrast-enhanced MR urographic examinations (5 normal; 23 pathologic) were post-processed to reconstruct a virtual ureterorenoscopy (VURS) using a threshold image segmentation. The visualization of the upper urinary tract was based on the acquisition of T{sub 1}-weighted 3D gradient-echo sequences after intravenous administration of gadolinium-DTPA and a prior injection of low-dose furosemide. Results: The employed MR urography technique created in all 28 cases a complete and strong contrast enhancement of the urinary tract. These 3D sequence data allowed the reconstruction of a VURS, even when the collecting system was not dilated. The best accuracy was provided by the MR urography sequences with the smallest voxel size. Moreover, the data acquisition based on a breath-hold technique has proved superior to that using a respiratory gating. Inside the renal pelvis, all calices could be assessed by turning the virtual endoscope in the appropriate direction. The visualization of the ureteral orifices in the bladder was also possible. All filling defects that were diagnosed by MR urography could be evaluated from the endoluminal view using the VURS. The exact characterization of the lesions based only on the assessment of the surface structure was difficult. Conclusion: A virtual endoscopy of the upper urinary tract can be successfully reconstructed using the data sets of high-resolution 3D MR urography sequences. (orig.) [Deutsch] Ziel: Untersuchungen zur Anwendung der virtuellen Endoskopie auf MR-tomographische Datensaetze des oberen Harntraktes. Methoden: Die Daten von 28 kontrastangehobenen MR-Urographien (5 normal; 23 pathologisch) wurden zur Erstellung einer virtuellen Ureterorenoskopie (VURS) mittels Schwellenwert-Bildsegmentierung nachverarbeitet. Als Grundlage fuer die Darstellung des Harntraktes

  9. Real-time holographic endoscopy

    Science.gov (United States)

    Smigielski, Paul; Albe, Felix; Dischli, Bernard

    1992-08-01

    Some new experiments concerning holographic endoscopy are presented. The quantitative measurements of deformations of objects are obtained by the double-exposure and double- reference beam method, using either a cw-laser or a pulsed laser. Qualitative experiments using an argon laser with time-average holographic endoscopy are also presented. A video film on real-time endoscopic holographic interferometry was recorded with the help of a frequency-doubled YAG-laser working at 25 Hz for the first time.

  10. European Society of Gastrointestinal Endoscopy, European Society of Gastroenterology and Endoscopy Nurses and Associates, and the European Society of Anaesthesiology Guideline: Non-anesthesiologist administration of propofol for GI endoscopy

    DEFF Research Database (Denmark)

    Dumonceau, J.M.; Riphaus, A.; Aparicio, J.R.

    2010-01-01

    Propofol sedation by non-anesthesiologists is an upcoming sedation regimen in several countries throughout Europe. Numerous studies have shown the efficacy and safety of this sedation regimen in gastrointestinal endoscopy. Nevertheless, this issue remains highly controversial. The aim of this evi......Propofol sedation by non-anesthesiologists is an upcoming sedation regimen in several countries throughout Europe. Numerous studies have shown the efficacy and safety of this sedation regimen in gastrointestinal endoscopy. Nevertheless, this issue remains highly controversial. The aim...... of this evidence- and consensus-based set of guideline is to provide non-anesthesiologists with a comprehensive framework for propofol sedation during digestive endoscopy. This guideline results from a collaborative effort from representatives of the European Society of Gastrointestinal Endoscopy (ESGE...

  11. Endoscopy and surgery for obesity

    International Nuclear Information System (INIS)

    Mejia, Andres Felipe; Unigarro, Ivan; Bolanos, Eduardo; Chaux, Carlos Felipe

    2006-01-01

    Actually bariatric surgery appears to be a secure, feasible and durable option for patients with morbid obesity. Most of the complications that arise from bariatric surgery can be solved with the use of endoscopy avoiding the morbidity and mortality of a surgical intervention. This group of patients has become a challenge for the endoscopist and favours the development of interventional endoscopy

  12. Capsule endoscopy: Beyond small bowel

    Directory of Open Access Journals (Sweden)

    Samuel N Adler

    2012-01-01

    Full Text Available In this article the brief and dramatic history of capsule endoscopy of the digestive tract is reviewed. Capsule endoscopy offers a non invasive method to diagnose diseases that affect the esophagus, small bowel and colon. Technological improvements relating to optics, software, data recorders with two way communication have revolutionized this field. These advancements have produced better diagnostic performance.

  13. Interactive navigation and bronchial tube tracking in virtual bronchoscopy.

    Science.gov (United States)

    Heng, P A; Fung, P F; Wong, T T; Siu, Y H; Sun, H

    1999-01-01

    An interactive virtual environment for simulation of bronchoscopy is developed. Medical doctor can safely plan their surgical bronchoscopy using the virtual environment without any invasive diagnosis which may risk the patient's health. The 3D pen input device of the system allows the doctor to navigate and visualize the bronchial tree of the patient naturally and interactively. To navigate the patient's bronchial tree, a vessel tracking process is required. While manual tracking is tedious and labor-intensive, fully automatic tracking may not be reliable. We propose a semi-automatic tracking technique called Intelligent Path Tracker which provides automation and enough user control during the vessel tracking. To support an interactive frame rate, we also introduce a new volume rendering acceleration technique, named as IsoRegion Leaping. The volume rendering is further accelerated by distributed rendering on a TCP/IP-based network of low-cost PCs. With these approaches, a 256 x 256 x 256 volume data of human lung, can be navigated and visualized at a frame rate of over 10 Hz in our virtual bronchoscopy system.

  14. Remote transmission of live endoscopy over the Internet: Report from the 87th Congress of the Japan Gastroenterological Endoscopy Society.

    Science.gov (United States)

    Shimizu, Shuji; Ohtsuka, Takao; Takahata, Shunichi; Nagai, Eishi; Nakashima, Naoki; Tanaka, Masao

    2016-01-01

    Live demonstration of endoscopy is one of the most attractive and useful methods for education and is often organized locally in hospitals. However, problems have been apparent in terms of cost, preparation, and potential risks to patients. Our aim was to evaluate a new approach to live endoscopy whereby remote hospitals are connected by the Internet for live endoscopic demonstrations. Live endoscopy was transmitted to the Congress of the Japan Gastroenterological Endoscopic Society by 13 domestic and international hospitals. Patients with upper and lower gastrointestinal diseases and with pancreatobiliary disorders were the subjects of a live demonstration. Questionnaires were distributed to the audience and were sent to the demonstrators. Questions concerned the quality of transmitted images and sound, cost, preparations, programs, preference of style, and adverse events. Of the audience, 91.2% (249/273) answered favorably regarding the transmitted image quality and 93.8% (259/276) regarding the sound quality. All demonstrators answered favorably regarding image quality and 93% (13/14) regarding sound quality. Preparations were completed without any outsourcing at 11 sites (79%) and were evaluated as 'very easy' or 'easy' at all but one site (92.3%). Preparation cost was judged as 'very cheap' or 'cheap' at 12 sites (86%). Live endoscopy connecting multiple international centers was satisfactory in image and sound quality for both audience and demonstrators, with easy and inexpensive preparation. The remote transmission of live endoscopy from demonstrators' own hospitals was preferred to the conventional style of locally organized live endoscopy. © 2015 The Authors Digestive Endoscopy © 2015 Japan Gastroenterological Endoscopy Society.

  15. Hindfoot endoscopy

    NARCIS (Netherlands)

    van Dijk, C. Niek

    2006-01-01

    Hindfoot pain can be caused by a variety of pathologies; most of these can be diagnosed and treated by means of endoscopy. The main indications are posterior tibial tenosynovectomy, diagnosis of a peroneus brevis length rupture, peroneal tendon athesiolysis, flexor hallucis longus release, os

  16. European Society of Gastrointestinal Endoscopy, European Society of Gastroenterology and Endoscopy Nurses and Associates, and the European Society of Anaesthesiology Guideline: Non-anaesthesiologist administration of propofol for GI endoscopy

    DEFF Research Database (Denmark)

    Dumonceau, J.M.; Riphaus, A.; Aparicio, J.R.

    2010-01-01

    ), the European Society of Gastroenterology and Endoscopy Nurses and Associates (ESGENA) and the European Society of Anaesthesiology (ESA). These three societies have endorsed the present guideline.The guideline is published simultaneously in the Journals Endoscopy and European Journal of Anaesthesiology....

  17. Low-Cost Interactive Image-Based Virtual Endoscopy for the Diagnosis and Surgical Planning of Suprasellar Arachnoid Cysts.

    Science.gov (United States)

    Li, Ye; Zhao, Yining; Zhang, Jiashu; Zhang, Zhizhong; Dong, Guojun; Wang, Qun; Liu, Lei; Yu, Xinguang; Xu, Bainan; Chen, Xiaolei

    2016-04-01

    To investigate the feasibility and reliability of virtual endoscopy (VE) as a rapid, low-cost, and interactive tool for the diagnosis and surgical planning of suprasellar arachnoid cysts (SACs). Eighteen patients with SACs treated with endoscopic ventriculocystostomy were recruited, and 18 endoscopic patients treated with third ventriculostomy were randomly selected as a VE reconstruction control group. After loading their DICOM data into free 3D Slicer software, VE reconstruction was independently performed by 3 blinded clinicians and the time required for each reconstruction was recorded. Another 3 blinded senior neurosurgeons interactively graded the visibility of VE by watching video recordings of the endoscopic procedures. Based on the visibility scores, receiver operating characteristic curve analysis was used to investigate the reliability of VE to diagnose SACs, and Bland-Altman plots were used to assess the reliability of VE for surgical planning. In addition, the intraclass correlation coefficient was calculated to estimate the consistency among the results of 3 reconstruction performers. All 3 independent reconstructing performers successfully completed VE simulation for all cases, and the average reconstruction time was 10.2 ± 9.7 minutes. The area under the receiver operating characteristic curve of the cyst visibility score was 0.96, implying its diagnostic value for SACs. The Bland-Altman plot indicated good agreement between VE and intraoperative viewings, suggesting the anatomic accuracy of the VE for surgical planning. In addition, the intraclass correlation coefficient was 0.81, which revealed excellent interperformer consistency of our simulation method. This study substantiated the feasibility and reliability of VE as a rapid, low-cost, and interactive modality for diagnosis and surgical planning of SACs. Copyright © 2016 Elsevier Inc. All rights reserved.

  18. 3D virtual rendering in thoracoscopic treatment of congenital malformation of the lung

    Directory of Open Access Journals (Sweden)

    Destro F.

    2013-10-01

    Full Text Available Introduction: Congenital malformations of the lung (CML are rare but potentially dangerous congenital malformations. Their identification is important in order to define the most appropriate management. Materials and methods: We retrospectively reviewed data from 37 patients affected by CML treated in our Pediatric Surgery Unit in the last four years with minimally invasive surgery (MIS. Results: Prenatal diagnosis was possible in 26/37 patients. Surgery was performed in the first month of life in 3 symptomatic patients and between 6 and 12 months in the others. All patients underwent radiological evaluation prior to thoracoscopic surgery. Images collected were reconstructed using the VR render software. Discussion and conclusions: Volume rendering gives high anatomical resolution and it can be useful to guide the surgical procedure. Thoracoscopy should be the technique of choice because it is safe, effective and feasible. Furthermore it has the benefit of a minimal access technique and it can be easily performed in children.

  19. Autofluorescence endoscopy: feasibility of detection of GI neoplasms unapparent to white light endoscopy with an evolving technology

    NARCIS (Netherlands)

    Haringsma, J.; Tytgat, G. N.; Yano, H.; Iishi, H.; Tatsuta, M.; Ogihara, T.; Watanabe, H.; Sato, N.; Marcon, N.; Wilson, B. C.; Cline, R. W.

    2001-01-01

    Case studies are presented of fluorescence endoscopy in the upper and lower GI tract to illustrate the ability to detect early-stage lesions that were not observable with white light endoscopy or those in which the assessment of the stage or extension of the lesion were equivocal. A new fluorescence

  20. RenderToolbox3: MATLAB tools that facilitate physically based stimulus rendering for vision research.

    Science.gov (United States)

    Heasly, Benjamin S; Cottaris, Nicolas P; Lichtman, Daniel P; Xiao, Bei; Brainard, David H

    2014-02-07

    RenderToolbox3 provides MATLAB utilities and prescribes a workflow that should be useful to researchers who want to employ graphics in the study of vision and perhaps in other endeavors as well. In particular, RenderToolbox3 facilitates rendering scene families in which various scene attributes and renderer behaviors are manipulated parametrically, enables spectral specification of object reflectance and illuminant spectra, enables the use of physically based material specifications, helps validate renderer output, and converts renderer output to physical units of radiance. This paper describes the design and functionality of the toolbox and discusses several examples that demonstrate its use. We have designed RenderToolbox3 to be portable across computer hardware and operating systems and to be free and open source (except for MATLAB itself). RenderToolbox3 is available at https://github.com/DavidBrainard/RenderToolbox3.

  1. upper gastrointestinal endoscopy findings in patients referred

    African Journals Online (AJOL)

    2014-08-01

    Aug 1, 2014 ... Objective: To determine the pattern of referral and endoscopy ... build a model of a flexible fibre imaging device (2) ..... a retrospective and prospective audit of all upper ... endoscopy should be reserved for the high risk.

  2. Current status of cleaning and disinfection for gastrointestinal endoscopy in China: a survey of 122 endoscopy units.

    Science.gov (United States)

    Zhang, Xiuli; Kong, Jinyan; Tang, Ping; Wang, Shufang; Hyder, Qurratulain; Sun, Gang; Zhang, Rugang; Yang, Yunsheng

    2011-04-01

    Adequate compliance with the existing guidelines for cleaning and disinfection of gastrointestinal endoscopes and accessories is necessary to obtain high-level disinfection and prevent pathogen transmission. To investigate cleaning and disinfection practice in China. A questionnaire with 21 questions concerning gastrointestinal endoscopy reprocessing was sent by e-mail to 189 endoscopy units in China. One hundred and twenty-two (80.39%) of the 189 units responded. Compared with the low-workload units (disinfectant (88.5%) in all the units. In 23/122 (18.8%) units, the exposure time to glutaraldehyde was <45 min in the case of infectious disease patients. Eighty-six of 122 (70.5%) units reused disposable materials, of which 21/86 (24.4%) reused disposable forceps and disposable polypectomy hooks, and 2/86 (1.6%) reused disposable injection needles intermittently. Although gastrointestinal endoscopy has developed rapidly in China in the past decade, there is still room for improvement in the practice of endoscopy reprocessing, especially in middle-sized and small cities. Copyright © 2011 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  3. Unsedated Flexible Upper Gastrointestinal Endoscopy: Need for ...

    African Journals Online (AJOL)

    Background: To determine the incidence of oxygen desaturation and whether routine oxygen monitoring is necessary during unsedated diagnostic flexible upper gastrointestinal endoscopy. Methods: A prospective study involving 54 consecutive in and out patients who had diagnostic upper gastrointestinal endoscopy at ...

  4. An image-based approach to the rendering of crowds in real-time

    OpenAIRE

    Tecchia, Franco

    2007-01-01

    The wide use of computer graphics in games, entertainment, medical, architectural and cultural applications, has led it to becoming a prevalent area of research. Games and entertainment in general have become one of the driving forces of the real-time computer graphics industry, bringing reasonably realistic, complex and appealing virtual worlds to the mass-market. At the current stage of technology, an user can interactively navigate through complex, polygon-based scenes rendered with sophis...

  5. Appropriateness of upper-GI endoscopy: an Italian survey on behalf of the Italian Society of Digestive Endoscopy.

    Science.gov (United States)

    Hassan, Cesare; Bersani, Gianluca; Buri, Luigi; Zullo, Angelo; Anti, Marcello; Bianco, Maria Antonia; Di Giulio, Emilio; Ficano, Leonardo; Morini, Sergio; Di Matteo, Giovanni; Loriga, Piero; Pietropaolo, Vincenzo; Cipolletta, Livio; Costamagna, Guido

    2007-05-01

    Open-access endoscopy allows physicians to directly schedule endoscopic procedures for their patients without prior consultation. An evaluation of both appropriateness and diagnostic yield of endoscopic procedures is critical when assessing the costs and benefits of endoscopy in an open-access setting. The aim of this Italian multicenter study was to assess the appropriate use of upper endoscopy (EGD) in an open-access system and to establish the yield of diagnostic information relevant to patient care. Cross-sectional, prospective, multicenter study. A total of 6270 patients referred to 44 Italian centers for open-access EGD during 1 month were prospectively enrolled. The American Society for Gastrointestinal Endoscopy (ASGE) guidelines were used to assess the relation between the appropriate use of EGD and the presence of relevant endoscopic findings. The rate for "generally not indicated" EGDs was 22.9%: 29.4% for primary care physicians and 12.9% for specialists (P 20, 99% CI 3 to >100; P < .01). Open-access EGD is an useful procedure for clinical practice. Because most of the relevant findings were detected during examinations performed for appropriate indications, the use of ASGE guidelines emerges as crucial to the cost-effectiveness of an open-access system.

  6. Immersive volume rendering of blood vessels

    Science.gov (United States)

    Long, Gregory; Kim, Han Suk; Marsden, Alison; Bazilevs, Yuri; Schulze, Jürgen P.

    2012-03-01

    In this paper, we present a novel method of visualizing flow in blood vessels. Our approach reads unstructured tetrahedral data, resamples it, and uses slice based 3D texture volume rendering. Due to the sparse structure of blood vessels, we utilize an octree to efficiently store the resampled data by discarding empty regions of the volume. We use animation to convey time series data, wireframe surface to give structure, and utilize the StarCAVE, a 3D virtual reality environment, to add a fully immersive element to the visualization. Our tool has great value in interdisciplinary work, helping scientists collaborate with clinicians, by improving the understanding of blood flow simulations. Full immersion in the flow field allows for a more intuitive understanding of the flow phenomena, and can be a great help to medical experts for treatment planning.

  7. Virtual environments simulation in research reactor

    Science.gov (United States)

    Muhamad, Shalina Bt. Sheik; Bahrin, Muhammad Hannan Bin

    2017-01-01

    Virtual reality based simulations are interactive and engaging. It has the useful potential in improving safety training. Virtual reality technology can be used to train workers who are unfamiliar with the physical layout of an area. In this study, a simulation program based on the virtual environment at research reactor was developed. The platform used for virtual simulation is 3DVia software for which it's rendering capabilities, physics for movement and collision and interactive navigation features have been taken advantage of. A real research reactor was virtually modelled and simulated with the model of avatars adopted to simulate walking. Collision detection algorithms were developed for various parts of the 3D building and avatars to restrain the avatars to certain regions of the virtual environment. A user can control the avatar to move around inside the virtual environment. Thus, this work can assist in the training of personnel, as in evaluating the radiological safety of the research reactor facility.

  8. Video-based rendering

    CERN Document Server

    Magnor, Marcus A

    2005-01-01

    Driven by consumer-market applications that enjoy steadily increasing economic importance, graphics hardware and rendering algorithms are a central focus of computer graphics research. Video-based rendering is an approach that aims to overcome the current bottleneck in the time-consuming modeling process and has applications in areas such as computer games, special effects, and interactive TV. This book offers an in-depth introduction to video-based rendering, a rapidly developing new interdisciplinary topic employing techniques from computer graphics, computer vision, and telecommunication en

  9. Non-anesthesiologist administration of propofol for gastrointestinal endoscopy

    DEFF Research Database (Denmark)

    Dumonceau, Jean-Marc; Riphaus, Andrea; Schreiber, Florian

    2015-01-01

    This Guideline is an official statement of the European Society of Gastrointestinal Endoscopy (ESGE) and the European Society of Gastroenterology and Endoscopy Nurses and Associates (ESGENA). It addresses the administration of propofol by non-anesthesiologists for gastrointestinal (GI) endoscopy...... driving, drinking alcohol, operating heavy machinery, or engaging in legally binding decisions. Advice should be provided verbally and in written form to the patient, including a 24-hour contact phone number (strong recommendation, low quality evidence). 10 For patients of ASA classes 1 - 2 who have...

  10. Nanotechnology in gastrointestinal endoscopy: A primer

    Directory of Open Access Journals (Sweden)

    Ashish Kumar Jha

    2012-01-01

    Full Text Available Nanotechnology is the understanding, control of matter and development of engineered devices in nanometer range (1-100 nm. Nanoparticles have different physicochemical properties (small size, large surface area to volume ratio, and high reactivity in comparison to bulk materials of the same composition. The nanotechnology has proved its usefulness in early diagnosis, proteonomics, imaging diagnostics and multifunctional therapeutics. Recent studies have shown its role in early diagnosis and targeted therapy of various gastrointestinal disorders such as hepatitis B virus and hepatitis C virus related liver disease, inflammatory bowel disease, gastric ulcer, and malignancy. Application of this technology appears promising in diagnostic and therapeutic endoscopy such as the endoscopic hemostasis of peptic ulcer bleeding, prevention of clogging of plastic stent and advance capsule endoscopy. This article will highlight the basic concepts of nanotechnology and its potential application in gastrointestinal endoscopy.

  11. Simultaneous functional photoacoustic and ultrasonic endoscopy of internal organs in vivo.

    Science.gov (United States)

    Yang, Joon-Mo; Favazza, Christopher; Chen, Ruimin; Yao, Junjie; Cai, Xin; Maslov, Konstantin; Zhou, Qifa; Shung, K Kirk; Wang, Lihong V

    2012-08-01

    At present, clinicians routinely apply ultrasound endoscopy in a variety of interventional procedures that provide treatment solutions for diseased organs. Ultrasound endoscopy not only produces high-resolution images, but also is safe for clinical use and broadly applicable. However, for soft tissue imaging, its mechanical wave-based image contrast fundamentally limits its ability to provide physiologically specific functional information. By contrast, photoacoustic endoscopy possesses a unique combination of functional optical contrast and high spatial resolution at clinically relevant depths, ideal for imaging soft tissues. With these attributes, photoacoustic endoscopy can overcome the current limitations of ultrasound endoscopy. Moreover, the benefits of photoacoustic imaging do not come at the expense of existing ultrasound functions; photoacoustic endoscopy systems are inherently compatible with ultrasound imaging, thereby enabling multimodality imaging with complementary contrast. Here we present simultaneous photoacoustic and ultrasonic dual-mode endoscopy and show its ability to image internal organs in vivo, thus illustrating its potential clinical application.

  12. Multi-viewpoint Image Array Virtual Viewpoint Rapid Generation Algorithm Based on Image Layering

    Science.gov (United States)

    Jiang, Lu; Piao, Yan

    2018-04-01

    The use of multi-view image array combined with virtual viewpoint generation technology to record 3D scene information in large scenes has become one of the key technologies for the development of integrated imaging. This paper presents a virtual viewpoint rendering method based on image layering algorithm. Firstly, the depth information of reference viewpoint image is quickly obtained. During this process, SAD is chosen as the similarity measure function. Then layer the reference image and calculate the parallax based on the depth information. Through the relative distance between the virtual viewpoint and the reference viewpoint, the image layers are weighted and panned. Finally the virtual viewpoint image is rendered layer by layer according to the distance between the image layers and the viewer. This method avoids the disadvantages of the algorithm DIBR, such as high-precision requirements of depth map and complex mapping operations. Experiments show that, this algorithm can achieve the synthesis of virtual viewpoints in any position within 2×2 viewpoints range, and the rendering speed is also very impressive. The average result proved that this method can get satisfactory image quality. The average SSIM value of the results relative to real viewpoint images can reaches 0.9525, the PSNR value can reaches 38.353 and the image histogram similarity can reaches 93.77%.

  13. Jaw Dislocation as an Unusual Complication of Upper Endoscopy

    Directory of Open Access Journals (Sweden)

    Evan S. Dellon

    2016-05-01

    Full Text Available This case report presents an unusual complication of upper endoscopy, resulting in jaw dislocation. Temporomandibular joint dislocation is commonly reported in association with anesthesia and intubation, but it is not widely recognized as a complication of gastrointestinal endoscopy. This report also reviews the current literature regarding this complication and discusses the potential causes of dislocation, differential diagnoses for jaw pain following endoscopy, and recommendations for prevention.

  14. Potential impact of enhanced practice efficiency on endoscopy waiting times.

    LENUS (Irish Health Repository)

    Harewood, G C

    2009-06-01

    With the growing demand on endoscopy services, optimising practice efficiency has assumed increasing importance. Prior research has identified practice changes, which increase the efficiency in endoscopy. In this study, the potential impact of these practice changes on the current and projected future endoscopy waiting times at our institution was assessed.

  15. Endoscopy services in KwaZulu-Natal Province, South Africa, are ...

    African Journals Online (AJOL)

    There were 0.06 registered gastroenterologists (GEs) per 100 000 population. Each endoscopist performed an average of 263 endoscopies per annum. There were 1.18 endoscopy rooms available per unit, and two units had on-site fluoroscopy available. The average waiting period for an upper endoscopy was 27 (range 7 ...

  16. Photometric stereo endoscopy.

    Science.gov (United States)

    Parot, Vicente; Lim, Daryl; González, Germán; Traverso, Giovanni; Nishioka, Norman S; Vakoc, Benjamin J; Durr, Nicholas J

    2013-07-01

    While color video endoscopy has enabled wide-field examination of the gastrointestinal tract, it often misses or incorrectly classifies lesions. Many of these missed lesions exhibit characteristic three-dimensional surface topographies. An endoscopic system that adds topographical measurements to conventional color imagery could therefore increase lesion detection and improve classification accuracy. We introduce photometric stereo endoscopy (PSE), a technique which allows high spatial frequency components of surface topography to be acquired simultaneously with conventional two-dimensional color imagery. We implement this technique in an endoscopic form factor and demonstrate that it can acquire the topography of small features with complex geometries and heterogeneous optical properties. PSE imaging of ex vivo human gastrointestinal tissue shows that surface topography measurements enable differentiation of abnormal shapes from surrounding normal tissue. Together, these results confirm that the topographical measurements can be obtained with relatively simple hardware in an endoscopic form factor, and suggest the potential of PSE to improve lesion detection and classification in gastrointestinal imaging.

  17. Optimization of Virtual Loudspeakers for Spatial Room Acoustics Reproduction with Headphones

    Directory of Open Access Journals (Sweden)

    Otto Puomio

    2017-12-01

    Full Text Available The use of headphones in reproducing spatial sound is becoming more and more popular. For instance, virtual reality applications often use head-tracking to keep the binaurally reproduced auditory environment stable and to improve externalization. Here, we study one spatial sound reproduction method over headphones, in particular the positioning of the virtual loudspeakers. The paper presents an algorithm that optimizes the positioning of virtual reproduction loudspeakers to reduce the computational cost in head-tracked real-time rendering. The listening test results suggest that listeners could discriminate the optimized loudspeaker arrays for renderings that reproduced a relatively simple acoustic conditions, but optimized array was not significantly different from equally spaced array for a reproduction of a more complex case. Moreover, the optimization seems to change the perceived openness and timbre, according to the verbal feedback of the test subjects.

  18. Cerebral gas embolism due to upper gastrointestinal endoscopy

    NARCIS (Netherlands)

    ter Laan, Mark; Totte, Erik; van Hulst, Rob A.; van der Linde, Klaas; van der Kamp, Wim; Pierie, Jean-Pierre E.

    Cerebral gas embolism as a result of upper gastrointestinal endoscopy is a rare complication and bares a high morbidity. A patient is presented who underwent an upper endoscopy for evaluation of a gastric-mediastinal fistula after subtotal oesophagectomy and gastric tube reconstruction because of

  19. Cerebral gas embolism due to upper gastrointestinal endoscopy

    NARCIS (Netherlands)

    ter Laan, Mark; Totte, Erik; van Hulst, Rob A.; van der Linde, Klaas; van der Kamp, Wim; Pierie, Jean-Pierre E.

    2009-01-01

    Cerebral gas embolism as a result of upper gastrointestinal endoscopy is a rare complication and bares a high morbidity. A patient is presented who underwent an upper endoscopy for evaluation of a gastric-mediastinal fistula after subtotal oesophagectomy and gastric tube reconstruction because of

  20. Diagnostic Yield of Microscopic Colitis in Open Access Endoscopy Center.

    Science.gov (United States)

    Ellingson, Derek; Miick, Ronald; Chang, Faye; Hillard, Robert; Choudhary, Abhishek; Ashraf, Imran; Bechtold, Matthew; Diaz-Arias, Alberto

    2011-08-01

    The diagnostic yield in open access endoscopy has been evaluated which generally support the effectiveness and efficiency of open access endoscopy. With a few exceptions, diagnostic yield studies have not been performed in open access endoscopy for more specific conditions. Therefore, we conducted a study to determine the efficiency of open access endoscopy in the detection of microscopic colitis as compared to traditional referral via a gastroenterologist. A retrospective search of the pathology database at the University of Missouri for specimens from a local open access endoscopy center was conducted via SNOMED code using the terms: "microscopic", "lymphocytic", "collagenous", "spirochetosis", "focal active colitis", "melanosis coli" and "histopathologic" in the diagnosis line for the time period between January 1, 2004 and May 25, 2006. Specimens and colonoscopy reports were reviewed by a single pathologist. Of 266 consecutive patients with chronic diarrhea and normal colonoscopies, the number of patients with microscopic disease are as follows: Lymphocytic colitis (n = 12, 4.5%), collagenous colitis (n = 17, 6.4%), focal active colitis (n = 15, 5.6%), and spirochetosis (n = 2, 0.4%). The diagnostic yield of microscopic colitis in this study of an open access endoscopy center does not differ significantly from that seen in major medical centers. In terms of diagnostic yield, open access endoscopy appears to be as effective in diagnosing microscopic colitis.

  1. Capsule endoscopy in the diagnosis of Crohn’s disease

    Directory of Open Access Journals (Sweden)

    Niv Y

    2013-05-01

    Full Text Available Yaron NivDepartment of Gastroenterology, Rabin Medical Center, Tel Aviv University, Petah Tikva, IsraelAbstract: Crohn’s disease is a chronic inflammatory disorder affecting any part of the gastrointestinal tract, but frequently involves the small and large bowel. Typical presenting symptoms include abdominal pain and diarrhea. Patients with this disorder may also have extraintestinal manifestations, including arthritis, uveitis, and skin lesions. The PillCam™SB capsule is an ingestible disposable video camera that transmits high quality images of the small intestinal mucosa. This enables the small intestine to be readily accessible to physicians investigating for the presence of small bowel disorders, such as Crohn’s disease. Four meta-analyses have demonstrated that capsule endoscopy identifies Crohn’s disease when other methods are not helpful. It should be noted that it is the best noninvasive procedure for assessing mucosal status, but is not superior to ileocolonoscopy, which remains the gold standard for assessment of ileocolonic disease. Mucosal healing along the small bowel can only be demonstrated by an endoscopic procedure such as capsule endoscopy. Achievement of long-term mucosal healing has been associated with a trend towards a decreased need for hospitalization and a decreased requirement for corticosteroid treatment in patients with Crohn’s disease. Recently, we have developed and validated the Capsule Endoscopy Crohn’s Disease Activity Index (also known as the Niv score for Crohn’s disease of the small bowel. The next step is to expand our score to the colon, and to determine the role and benefit of a capsule endoscopy activity score in patients suffering from Crohn’s ileocolitis and/or colitis. This scoring system will also serve to improve our understanding of the impact of capsule endoscopy, and therefore treatment, on the immediate outcome of this disorder. As the best procedure available for assessing

  2. Magnetically guided capsule endoscopy.

    Science.gov (United States)

    Shamsudhin, Naveen; Zverev, Vladimir I; Keller, Henrik; Pane, Salvador; Egolf, Peter W; Nelson, Bradley J; Tishin, Alexander M

    2017-08-01

    Wireless capsule endoscopy (WCE) is a powerful tool for medical screening and diagnosis, where a small capsule is swallowed and moved by means of natural peristalsis and gravity through the human gastrointestinal (GI) tract. The camera-integrated capsule allows for visualization of the small intestine, a region which was previously inaccessible to classical flexible endoscopy. As a diagnostic tool, it allows to localize the sources of bleedings in the middle part of the gastrointestinal tract and to identify diseases, such as inflammatory bowel disease (Crohn's disease), polyposis syndrome, and tumors. The screening and diagnostic efficacy of the WCE, especially in the stomach region, is hampered by a variety of technical challenges like the lack of active capsular position and orientation control. Therapeutic functionality is absent in most commercial capsules, due to constraints in capsular volume and energy storage. The possibility of using body-exogenous magnetic fields to guide, orient, power, and operate the capsule and its mechanisms has led to increasing research in Magnetically Guided Capsule Endoscopy (MGCE). This work shortly reviews the history and state-of-art in WCE technology. It highlights the magnetic technologies for advancing diagnostic and therapeutic functionalities of WCE. Not restricting itself to the GI tract, the review further investigates the technological developments in magnetically guided microrobots that can navigate through the various air- and fluid-filled lumina and cavities in the body for minimally invasive medicine. © 2017 American Association of Physicists in Medicine.

  3. Virtual reality in medicine-computer graphics and interaction techniques.

    Science.gov (United States)

    Haubner, M; Krapichler, C; Lösch, A; Englmeier, K H; van Eimeren, W

    1997-03-01

    This paper describes several new visualization and interaction techniques that enable the use of virtual environments for routine medical purposes. A new volume-rendering method supports shaded and transparent visualization of medical image sequences in real-time with an interactive threshold definition. Based on these rendering algorithms two complementary segmentation approaches offer an intuitive assistance for a wide range of requirements in diagnosis and therapy planning. In addition, a hierarchical data representation for geometric surface descriptions guarantees an optimal use of available hardware resources and prevents inaccurate visualization. The combination of the presented techniques empowers the improved human-machine interface of virtual reality to support every interactive task in medical three-dimensional (3-D) image processing, from visualization of unsegmented data volumes up to the simulation of surgical procedures.

  4. High-fidelity haptic and visual rendering for patient-specific simulation of temporal bone surgery.

    Science.gov (United States)

    Chan, Sonny; Li, Peter; Locketz, Garrett; Salisbury, Kenneth; Blevins, Nikolas H

    2016-12-01

    Medical imaging techniques provide a wealth of information for surgical preparation, but it is still often the case that surgeons are examining three-dimensional pre-operative image data as a series of two-dimensional images. With recent advances in visual computing and interactive technologies, there is much opportunity to provide surgeons an ability to actively manipulate and interpret digital image data in a surgically meaningful way. This article describes the design and initial evaluation of a virtual surgical environment that supports patient-specific simulation of temporal bone surgery using pre-operative medical image data. Computational methods are presented that enable six degree-of-freedom haptic feedback during manipulation, and that simulate virtual dissection according to the mechanical principles of orthogonal cutting and abrasive wear. A highly efficient direct volume renderer simultaneously provides high-fidelity visual feedback during surgical manipulation of the virtual anatomy. The resulting virtual surgical environment was assessed by evaluating its ability to replicate findings in the operating room, using pre-operative imaging of the same patient. Correspondences between surgical exposure, anatomical features, and the locations of pathology were readily observed when comparing intra-operative video with the simulation, indicating the predictive ability of the virtual surgical environment.

  5. Subliminal Cueing of Selection Behavior in a Virtual Environment

    OpenAIRE

    Aranyi, Gabor; Kouider, Sid; Lindsay, Alan; Prins, Hielke; Ahmed, Imtiaj; Jacucci, Giulio; Negri, Paolo; Gamberini, Luciano; Pizzi, David; Cavazza, Marc

    2014-01-01

    The performance of current graphics engines makes it possible to incorporate subliminal cues within virtual environments (VEs), providing an additional way of communication,\\ud fully integrated with the exploration of a virtual scene. In order to advance the application of subliminal information in this area, it is necessary to explore how techniques\\ud previously reported as rendering information subliminal in the psychological literature can be successfully implemented in VEs. Previous lite...

  6. Correlation between perception of color, shadows, and surface textures and the realism of a scene in virtual reality.

    Science.gov (United States)

    Pardo, Pedro J; Suero, María Isabel; Pérez, Ángel Luis

    2018-04-01

    Head-mounted displays allow us to go through immersive experiences in virtual reality and are expected to be present in more and more applications in both recreational and professional fields. In this context, recent years have witnessed significant advances in rendering techniques following physical models of lighting and shading. The aim of this paper is to check the fidelity of the visual appearance of real objects captured through a 3D scanner, rendered in a personal computer and displayed in a virtual reality device. We have compared forward versus deferred rendering in real-time computing using two different illuminations and five artwork replicas. The survey contains seven items for each artwork (color, shading, texture, definition, geometry, chromatic aberration, and pixelation) and an extra item related to the global realism. The results confirm recent advances in virtual reality, showing considerable visual fidelity of generated to real-world images, with a rate close to 4 in a 5-step perceptive scale. They also show a high correlation of the realism sensation with the fidelity of color reproduction, material texture, and definition of the artwork replicas. Moreover, statistically significant differences between two rendering modes are found, with a higher value of realism sensation in the deferred rendering mode.

  7. Arteriovenous Malformation Detected by Small Bowel Endoscopy

    Directory of Open Access Journals (Sweden)

    Takaaki Fujii

    2014-10-01

    Full Text Available Gastrointestinal bleeding that originates in the small intestine is often difficult to diagnose. When successful diagnosis reveals a lesion that can be localized preoperatively, the laparoscopic approach is an appropriate and beneficial treatment modality for small bowel resection. A 69-year-old man presented with a 6-month history of gastrointestinal bleeding and symptomatic transfusion-dependent anemia. Upper and lower endoscopy were normal. Double-balloon endoscopy established the source of the bleeding as a 0.5-cm polypoid mass appearing as a submucosal tumor with redness and pulsation in the lower ileum, suggesting a vascular lesion. Laparoscopic small bowel resection was successful in removing the mass in the ileum. Histological evaluation of the mass revealed an arteriovenous malformation. Preoperative small bowel endoscopy can be useful for diagnosing the cause and localization of arteriovenous malformation in the small intestine.

  8. Diagnosis of Adult Chronic Rhinosinusitis: Can Nasal Endoscopy Predict Intrasinus Disease?

    Directory of Open Access Journals (Sweden)

    Arif Ali Kolethekkat

    2013-11-01

    Full Text Available Objectives: To define the role of endoscopic evaluation of middle meatus in adult patients clinically diagnosed to have chronic rhino-sinusitis and its ability to predict intra-sinus mucosal involvement as compared to CT scan.Methods: This prospective analytical study was conducted on consecutive patients with diagnosis of chronic rhino-sinusitis who were symptomatic and fulfilled the American Academy of Otolaryngology - Head and Neck Surgery Task Force criteria. The patients were enrolled prospectively and were subjected to rigid diagnostic nasal endoscopy and classified as defined by the revised Sinus Allergy Health Partnership Task Force criteria. The patients then underwent non contrast CT sinuses on the same day. Results were analyzed as a diagnostic test evaluation using CT as a gold standard.Results: Among the 75 study patients with symptom based chronic rhino-sinusitis, nasal endoscopy was abnormal in 65 patients (87%. Of these patients, 60/65 (92% showed positive findings on CT scan. Ten patients had normal endoscopy, of these 6/10 (60% had abnormal CT scan. Sensitivity and specificity of diagnostic nasal endoscopy against CT scan were 91% (95% CI: 81-97 and 44% (95% CI: 14-79, respectively. The likelihood ratio for positive nasal endoscopy to diagnose chronic rhino-sinusitis was 1.6 and the likelihood ratio to rule out chronic rhino-sinusitis when endoscopy was negative was 0.2.Conclusion: Nasal endoscopy is a valid and objective diagnostic tool in the work up of patients with symptomatic chronic rhino-sinusitis. When clinical suspicion is low (90% of patients when clinical suspicion is high (88% as defined in this study by AAO-HNS Task Force criteria. Negative endoscopy, however, does not totally exclude the sinus disease in patients fulfilling task force criteria. CT scan may be needed on follow-up if there is clinical suspicion in 10% of these patients who are negative on endoscopy if symptoms persists. It is thus possible to reduce

  9. Studying and Incorporating Efficiency into Gastrointestinal Endoscopy Centers

    Directory of Open Access Journals (Sweden)

    Lukejohn W. Day

    2015-01-01

    Full Text Available Efficiency is defined as the use of resources in such a way as to maximize the production of goods and services. Improving efficiency has been the focus of management in many industries; however, it has not been until recently that incorporating efficiency models into healthcare has occurred. In particular, the study and development of improvement projects aimed at enhancing efficiency in GI have been growing rapidly in recent years. This focus on improving efficiency in GI has been spurred by the dramatic rise in the demand for endoscopic procedures as well as the rising number of insured patients requiring GI care coupled at the same time with limited resources in terms of staffing and space in endoscopy centers. This paper will critically review the history of efficiency in endoscopy centers, first by looking at other healthcare industries that have extensively studied and improved efficiency in their fields, examine a number of proposed efficiency metrics and benchmarks in endoscopy centers, and finally discuss opportunities where endoscopy centers could improve their efficiency.

  10. Virtual reality in advanced medical immersive imaging: a workflow for introducing virtual reality as a supporting tool in medical imaging

    KAUST Repository

    Knodel, Markus M.

    2018-02-27

    Radiologic evaluation of images from computed tomography (CT) or magnetic resonance imaging for diagnostic purposes is based on the analysis of single slices, occasionally supplementing this information with 3D reconstructions as well as surface or volume rendered images. However, due to the complexity of anatomical or pathological structures in biomedical imaging, innovative visualization techniques are required to display morphological characteristics three dimensionally. Virtual reality is a modern tool of representing visual data, The observer has the impression of being “inside” a virtual surrounding, which is referred to as immersive imaging. Such techniques are currently being used in technical applications, e.g. in the automobile industry. Our aim is to introduce a workflow realized within one simple program which processes common image stacks from CT, produces 3D volume and surface reconstruction and rendering, and finally includes the data into a virtual reality device equipped with a motion head tracking cave automatic virtual environment system. Such techniques have the potential to augment the possibilities in non-invasive medical imaging, e.g. for surgical planning or educational purposes to add another dimension for advanced understanding of complex anatomical and pathological structures. To this end, the reconstructions are based on advanced mathematical techniques and the corresponding grids which we can export are intended to form the basis for simulations of mathematical models of the pathogenesis of different diseases.

  11. VIRTUAL ARCHAEOLOGICAL ENVIRONMENTS GENERATED IN AVAYALIVE ENGAGE

    Directory of Open Access Journals (Sweden)

    ANTHONY Rigby

    2014-09-01

    Full Text Available Realistically rendered and textured virtual spaces can be created in the AVAYALIVE ENGAGE platform by importing high polygon models and scaled accurately reproduced textures. In addition MellaniuM has successfully developed an application for utilizing all the archaeological virtual assets developed in 3D Studio Max or generated over the past several years using photogrammetry and laser scanning. It is possible therefore to create interactive environments of archaeological significance that can be accessed through the Internet and available to up to 40 participants. 

  12. Conservation of old renderings - the consolidation of rendering with loss of cohesion

    Directory of Open Access Journals (Sweden)

    Martha Tavares

    2008-01-01

    Full Text Available The study of external renderings in the scope of conservation and restoration has acquired in the last years great methodological, scientific and technical advances. These renderings are important elements of the built structure, for besides possessing a protection function, they possess often a decorative function of great relevance for the image of the monument. The maintenance of these renderings implies the conservation of traditional constructive techniques and the use of compatible materials, as similar to the originals as possible. The main objective of this study is to define a methodology of conservative restoration using strategies of maintenance of renderings and traditional constructive techniques. The minimum intervention principle is maintained as well as the use of materials compatible with the original ones. This paper describes the technique and products used for the consolidation of the loss of cohesion. The testing campaign was developed under controlled conditions, in laboratory, and in situ in order to evaluate their efficacy for the consolidation of old renders. A set of tests is presented to evaluate the effectiveness of the process. The results are analysed and a reflection is added referring to the applicability of these techniques. Finally the paper presents a proposal for further research.

  13. What we have learned and what to expect from capsule endoscopy.

    Science.gov (United States)

    Adler, Samuel N; Bjarnason, Ingvar

    2012-10-16

    Capsule endoscopy was conceived by Gabriel Iddan and Paul Swain independently two decades ago. These applications include but are not limited to Crohn's disease of the small bowel, occult gastrointestinal bleeding, non steroidal anti inflammatory drug induced small bowel disease, carcinoid tumors of the small bowel, gastro intestinal stromal tumors of the small bowel and other disease affecting the small bowel. Capsule endoscopy has been compared to traditional small bowel series, computerized tomography studies and push enteroscopy. The diagnostic yield of capsule endoscopy has consistently been superior in the diagnosis of small bowel disease compared to the competing methods (small bowel series, computerized tomography, push enteroscopy) of diagnosis. For this reason capsule endoscopy has enjoyed a meteoric success. Image quality has been improved with increased number of pixels, automatic light exposure adaptation and wider angle of view. Further applications of capsule endoscopy of other areas of the digestive tract are being explored. The increased transmission rate of images per second has made capsule endoscopy of the esophagus a realistic possibility. Technological advances that include a double imager capsule with a nearly panoramic view of the colon and a variable frame rate adjusted to the movement of the capsule in the colon have made capsule endoscopy of the colon feasible. The diagnostic rate for the identification of patients with polyps equal to or larger than 6 mm is high. Future advances in technology and biotechnology will lead to further progress. Capsule endoscopy is following the successful modern trend in medicine that replaces invasive tests with less invasive methodology.

  14. Simulation and training of lumbar punctures using haptic volume rendering and a 6DOF haptic device

    Science.gov (United States)

    Färber, Matthias; Heller, Julika; Handels, Heinz

    2007-03-01

    The lumbar puncture is performed by inserting a needle into the spinal chord of the patient to inject medicaments or to extract liquor. The training of this procedure is usually done on the patient guided by experienced supervisors. A virtual reality lumbar puncture simulator has been developed in order to minimize the training costs and the patient's risk. We use a haptic device with six degrees of freedom (6DOF) to feedback forces that resist needle insertion and rotation. An improved haptic volume rendering approach is used to calculate the forces. This approach makes use of label data of relevant structures like skin, bone, muscles or fat and original CT data that contributes information about image structures that can not be segmented. A real-time 3D visualization with optional stereo view shows the punctured region. 2D visualizations of orthogonal slices enable a detailed impression of the anatomical context. The input data consisting of CT and label data and surface models of relevant structures is defined in an XML file together with haptic rendering and visualization parameters. In a first evaluation the visible human male data has been used to generate a virtual training body. Several users with different medical experience tested the lumbar puncture trainer. The simulator gives a good haptic and visual impression of the needle insertion and the haptic volume rendering technique enables the feeling of unsegmented structures. Especially, the restriction of transversal needle movement together with rotation constraints enabled by the 6DOF device facilitate a realistic puncture simulation.

  15. A Study of Power and Individualism in Virtual Teams: Trends, Challenges, and Solutions

    Science.gov (United States)

    Jablonski, Deirdre

    2013-01-01

    This study investigated the relationship between cultural values and effectiveness of virtual team processes. In order to render an acceptable degree of comparison, four specific team outcomes of virtual team effectiveness were aligned on Hofstede's cultural dimensions of power distance and individualism. The lack of awareness of how power and…

  16. From POEM to POET: Applications and perspectives for submucosal tunnel endoscopy.

    Science.gov (United States)

    Chiu, Philip W Y; Inoue, Haruhiro; Rösch, Thomas

    2016-12-01

    Recent advances in submucosal endoscopy have unlocked a new horizon for potential development in diagnostic and therapeutic endoscopy. Increasing evidence has demonstrated that peroral endoscopic myotomy (POEM) is not only clinically feasible and safe, but also has excellent results in symptomatic relief of achalasia. The success of submucosal endoscopy in performance of tumor resection has confirmed the potential of this new area in diagnostic and therapeutic endoscopy. This article reviews the current applications and evidence, from POEM to peroral endoscopic tunnel resection (POET), while exploring the possible future clinical applications in this field. © Georg Thieme Verlag KG Stuttgart · New York.

  17. Enhancing Tele-robotics with Immersive Virtual Reality

    Science.gov (United States)

    2017-11-03

    The spheres displayed in the virtual environment represent the real-world readings from the robot in real-time from its LRF and sonar sensors. In...Inc., is comprised of an advanced graphics rendering engine, sound engine, and physics and animation engines. This game engine is capable of delivering

  18. Walking in a Virtual Town using Nintendo Wiimote and Balance Board

    Directory of Open Access Journals (Sweden)

    Lucio Tommaso De Paolis

    2011-12-01

    Full Text Available EnThe main goal of the Human-Computer Interaction technology is to improve the interactions between users and computers by making computers more usable and receptive to the user's needs. The end point in the interface design would then lead to a paradigm in which the interaction with computers becomes similar to the one between human beings. This paper focuses on an application of navigation and interaction in a virtual environment using the Nintendo Wiimote and the Balance Board. The idea is to have a system of navigation control in a virtual environment based on a locomotion interface in order to make the interaction easier for users without any experience of navigation in a virtual world and more efficient for trained users. The application has been developed for the navigation and interaction in the virtual town. We chose Otranto as an example town; Otranto is located in the easternmost tip of the Italian peninsula and, due to its geographical position, the town was like a bridge between East and West. The virtual environment is a loyal representation of the town of Otranto in the Middle Ages.ItL'obiettivo principale della Human-Computer Interaction technology è il miglioramento delle interazioni tra utenti e computer al fine di rendere tali sistemi più usabili e più adatti a soddisfare le diverse esigenze degli utenti. Il punto di arrivo nella progettazione di un’interfaccia sarebbe, quindi, quello rendere l'interazione con i computer simile quanto più possibile a quella tra esseri umani. Questo paper presenta un'applicazione che permette la navigazione e l’interazione in un ambiente virtuale facendo uso del Wiimote e della Balance Board della Nintendo. L'idea è di disporre di un sistema di controllo della navigazione in un ambiente virtuale basato su una semplice interfaccia di locomozione in grado di rendere più semplice l'interazione per gli utenti senza alcuna esperienza di navigazione in un mondo virtuale e più efficiente

  19. Apport de l'endoscopie digestive dans l'hypertension portale de l ...

    African Journals Online (AJOL)

    ... le rôle de l'endoscopie dans le traitement et la surveillance. Méthodes: Notre étude est une analyse rétrospective de 135 endoscopies digestives hautes effectuées chez 68 enfants atteints d'hypertension portale sur une période de 8 ans. Résultats: L'endoscopie a permis de mettre en évidence les varices oesogastriques ...

  20. Transnasal endoscopy: Technical considerations, advantages and limitations.

    Science.gov (United States)

    Atar, Mustafa; Kadayifci, Abdurrahman

    2014-02-16

    Transnasal endoscopy (TNE) is an upper endoscopy method which is performed by the nasal route using a thin endoscope less than 6 mm in diameter. The primary goal of this method is to improve patient tolerance and convenience of the procedure. TNE can be performed without sedation and thus eliminates the risks associated with general anesthesia. In this way, TNE decreases the cost and total duration of endoscopic procedures, while maintaining the image quality of standard caliber endoscopes, providing good results for diagnostic purposes. However, the small working channel of the ultra-thin endoscope used for TNE makes it difficult to use for therapeutic procedures except in certain conditions which require a thinner endoscope. Biopsy is possible with special forceps less than 2 mm in diameter. Recently, TNE has been used for screening endoscopy in Far East Asia, including Japan. In most controlled studies, TNE was found to have better patient tolerance when compared to unsedated endoscopy. Nasal pain is the most significant symptom associated with endoscopic procedures but can be reduced with nasal pretreatment. Despite the potential advantage of TNE, it is not common in Western countries, usually due to a lack of training in the technique and a lack of awareness of its potential advantages. This paper briefly reviews the technical considerations as well as the potential advantages and limitations of TNE with ultra-thin scopes.

  1. Transnasal endoscopy: Technical considerations, advantages and limitations

    Science.gov (United States)

    Atar, Mustafa; Kadayifci, Abdurrahman

    2014-01-01

    Transnasal endoscopy (TNE) is an upper endoscopy method which is performed by the nasal route using a thin endoscope less than 6 mm in diameter. The primary goal of this method is to improve patient tolerance and convenience of the procedure. TNE can be performed without sedation and thus eliminates the risks associated with general anesthesia. In this way, TNE decreases the cost and total duration of endoscopic procedures, while maintaining the image quality of standard caliber endoscopes, providing good results for diagnostic purposes. However, the small working channel of the ultra-thin endoscope used for TNE makes it difficult to use for therapeutic procedures except in certain conditions which require a thinner endoscope. Biopsy is possible with special forceps less than 2 mm in diameter. Recently, TNE has been used for screening endoscopy in Far East Asia, including Japan. In most controlled studies, TNE was found to have better patient tolerance when compared to unsedated endoscopy. Nasal pain is the most significant symptom associated with endoscopic procedures but can be reduced with nasal pretreatment. Despite the potential advantage of TNE, it is not common in Western countries, usually due to a lack of training in the technique and a lack of awareness of its potential advantages. This paper briefly reviews the technical considerations as well as the potential advantages and limitations of TNE with ultra-thin scopes. PMID:24567791

  2. The Effect of Realistic Appearance of Virtual Characters in Immersive Environments - Does the Character's Personality Play a Role?

    Science.gov (United States)

    Zibrek, Katja; Kokkinara, Elena; Mcdonnell, Rachel

    2018-04-01

    Virtual characters that appear almost photo-realistic have been shown to induce negative responses from viewers in traditional media, such as film and video games. This effect, described as the uncanny valley, is the reason why realism is often avoided when the aim is to create an appealing virtual character. In Virtual Reality, there have been few attempts to investigate this phenomenon and the implications of rendering virtual characters with high levels of realism on user enjoyment. In this paper, we conducted a large-scale experiment on over one thousand members of the public in order to gather information on how virtual characters are perceived in interactive virtual reality games. We were particularly interested in whether different render styles (realistic, cartoon, etc.) would directly influence appeal, or if a character's personality was the most important indicator of appeal. We used a number of perceptual metrics such as subjective ratings, proximity, and attribution bias in order to test our hypothesis. Our main result shows that affinity towards virtual characters is a complex interaction between the character's appearance and personality, and that realism is in fact a positive choice for virtual characters in virtual reality.

  3. Man, mind, and machine: the past and future of virtual reality simulation in neurologic surgery.

    Science.gov (United States)

    Robison, R Aaron; Liu, Charles Y; Apuzzo, Michael L J

    2011-11-01

    To review virtual reality in neurosurgery, including the history of simulation and virtual reality and some of the current implementations; to examine some of the technical challenges involved; and to propose a potential paradigm for the development of virtual reality in neurosurgery going forward. A search was made on PubMed using key words surgical simulation, virtual reality, haptics, collision detection, and volumetric modeling to assess the current status of virtual reality in neurosurgery. Based on previous results, investigators extrapolated the possible integration of existing efforts and potential future directions. Simulation has a rich history in surgical training, and there are numerous currently existing applications and systems that involve virtual reality. All existing applications are limited to specific task-oriented functions and typically sacrifice visual realism for real-time interactivity or vice versa, owing to numerous technical challenges in rendering a virtual space in real time, including graphic and tissue modeling, collision detection, and direction of the haptic interface. With ongoing technical advancements in computer hardware and graphic and physical rendering, incremental or modular development of a fully immersive, multipurpose virtual reality neurosurgical simulator is feasible. The use of virtual reality in neurosurgery is predicted to change the nature of neurosurgical education, and to play an increased role in surgical rehearsal and the continuing education and credentialing of surgical practitioners. Copyright © 2011 Elsevier Inc. All rights reserved.

  4. Helicobacter pylori as an occupational hazard in the endoscopy room

    African Journals Online (AJOL)

    South African Journal of Surgery ... Background: It remains controversial whether or not healthcare workers on upper ... We were unable to confirm that endoscopy was a risk factor for endoscopy teams with regard to contracting H. pylori.

  5. Rendering of Gemstones

    OpenAIRE

    Krtek, Lukáš

    2012-01-01

    The distinctive appearance of gemstones is caused by the way light reflects and refracts multiple times inside of them. The goal of this thesis is to design and implement an application for photorealistic rendering of gems. The most important effects we aim for are realistic dispersion of light and refractive caustics. For rendering we use well-known algorithm of path tracing with an experimental modification for faster computation of caustic effects. In this thesis we also design and impleme...

  6. Endoscopy services in KwaZulu-Natal Province, South Africa, are ...

    African Journals Online (AJOL)

    is based on the values and principles of primary healthcare, but major discrepancies ... To audit the GI endoscopy services in KZN and compare these with the current guidelines for ..... Quality assurance of endoscopy units. Best Pract Res Clin ...

  7. The validity of nasal endoscopy in patients with chronic rhinosinusitis

    DEFF Research Database (Denmark)

    Larsen, K. L.; Lange, B.; Darling, P.

    2018-01-01

    Objectives: Nasal endoscopy is a cornerstone in diagnosing sinonasal disease, but different raters might generate different results using the technique. Our study aims to evaluate the agreement between multiple raters to assess the validity of nasal endoscopy. Design/Participants: Three independe...

  8. ISMCR 1994: Topical Workshop on Virtual Reality. Proceedings of the Fourth International Symposium on Measurement and Control in Robotics

    Science.gov (United States)

    1994-01-01

    This symposium on measurement and control in robotics included sessions on: (1) rendering, including tactile perception and applied virtual reality; (2) applications in simulated medical procedures and telerobotics; (3) tracking sensors in a virtual environment; (4) displays for virtual reality applications; (5) sensory feedback including a virtual environment application with partial gravity simulation; and (6) applications in education, entertainment, technical writing, and animation.

  9. Canadian Association of Gastroenterology consensus guidelines on safety and quality indicators in endoscopy.

    Science.gov (United States)

    Armstrong, David; Barkun, Alan; Bridges, Ron; Carter, Rose; de Gara, Chris; Dube, Catherine; Enns, Robert; Hollingworth, Roger; Macintosh, Donald; Borgaonkar, Mark; Forget, Sylviane; Leontiadis, Grigorios; Meddings, Jonathan; Cotton, Peter; Kuipers, Ernst J

    2012-01-01

    Increasing use of gastrointestinal endoscopy, particularly for colorectal cancer screening, and increasing emphasis on health care quality, highlight the need for clearly defined, evidence-based processes to support quality improvement in endoscopy. To identify processes and indicators of quality and safety relevant to high-quality endoscopy service delivery. A multidisciplinary group of 35 voting participants developed recommendation statements and performance indicators. Systematic literature searches generated 50 initial statements that were revised iteratively following a modified Delphi approach using a web-based evaluation and voting tool. Statement development and evidence evaluation followed the AGREE (Appraisal of Guidelines, REsearch and Evaluation) and GRADE (Grading of Recommendations, Assessment, Development and Evaluation) guidelines. At the consensus conference, participants voted anonymously on all statements using a 6-point scale. Subsequent web-based voting evaluated recommendations for specific, individual quality indicators, safety indicators and mandatory endoscopy reporting fields. Consensus was defined a priori as agreement by 80% of participants. Consensus was reached on 23 recommendation statements addressing the following: ethics (statement 1: agreement 100%), facility standards and policies (statements 2 to 9: 90% to 100%), quality assurance (statements 10 to 13: 94% to 100%), training, education, competency and privileges (statements 14 to 19: 97% to 100%), endoscopy reporting standards (statements 20 and 21: 97% to 100%) and patient perceptions (statements 22 and 23: 100%). Additionally, 18 quality indicators (agreement 83% to 100%), 20 safety indicators (agreement 77% to 100%) and 23 recommended endoscopy-reporting elements (agreement 91% to 100%) were identified. The consensus process identified a clear need for high-quality clinical and outcomes research to support quality improvement in the delivery of endoscopy services. The

  10. Non-small-bowel abnormalities identified during small bowel capsule endoscopy

    NARCIS (Netherlands)

    Hoedemakers, Reinier; Westerhof, Jessie; Weersma, Rinse K.; Koornstra, Jan J.

    2014-01-01

    AIM: To investigate the incidence of non-small-bowel abnormalities in patients referred for small bowel capsule endoscopy, this single center study was performed. METHODS: Small bowel capsule endoscopy is an accepted technique to investigate obscure gastrointestinal bleeding. This is defined as

  11. Latency in Distributed Acquisition and Rendering for Telepresence Systems.

    Science.gov (United States)

    Ohl, Stephan; Willert, Malte; Staadt, Oliver

    2015-12-01

    Telepresence systems use 3D techniques to create a more natural human-centered communication over long distances. This work concentrates on the analysis of latency in telepresence systems where acquisition and rendering are distributed. Keeping latency low is important to immerse users in the virtual environment. To better understand latency problems and to identify the source of such latency, we focus on the decomposition of system latency into sub-latencies. We contribute a model of latency and show how it can be used to estimate latencies in a complex telepresence dataflow network. To compare the estimates with real latencies in our prototype, we modify two common latency measurement methods. This presented methodology enables the developer to optimize the design, find implementation issues and gain deeper knowledge about specific sources of latency.

  12. Transformative Rendering of Internet Resources

    Science.gov (United States)

    2012-10-01

    using either the Firefox or Google Chrome rendering engine. The rendering server then captures a screen shot of the page and creates code that positions...be compromised at web pages the hackers had built for that hacking competition to exploit that particular OS /browser configuration. During...of risk with no benefit. They include: - The rendering server is hosted on a Linux-based operating system ( OS ). The OS is much more secure than the

  13. A model for flexible tools used in minimally invasive medical virtual environments.

    Science.gov (United States)

    Soler, Francisco; Luzon, M Victoria; Pop, Serban R; Hughes, Chris J; John, Nigel W; Torres, Juan Carlos

    2011-01-01

    Within the limits of current technology, many applications of a virtual environment will trade-off accuracy for speed. This is not an acceptable compromise in a medical training application where both are essential. Efficient algorithms must therefore be developed. The purpose of this project is the development and validation of a novel physics-based real time tool manipulation model, which is easy to integrate into any medical virtual environment that requires support for the insertion of long flexible tools into complex geometries. This encompasses medical specialities such as vascular interventional radiology, endoscopy, and laparoscopy, where training, prototyping of new instruments/tools and mission rehearsal can all be facilitated by using an immersive medical virtual environment. Our model recognises and uses accurately patient specific data and adapts to the geometrical complexity of the vessel in real time.

  14. Improving the timeliness of procedures in a pediatric endoscopy suite.

    Science.gov (United States)

    Tomer, Gitit; Choi, Steven; Montalvo, Andrea; Sutton, Sheila; Thompson, John; Rivas, Yolanda

    2014-02-01

    Pediatric endoscopic procedures are essential in the evaluation and treatment of gastrointestinal diseases in children. Although pediatric endoscopists are greatly interested in increasing efficiency and through-put in pediatric endoscopy units, there is scarcely any literature on this critical process. The goal of this study was to improve the timeliness of pediatric endoscopy procedures at Children's Hospital at Montefiore. In June 2010, a pediatric endoscopy quality improvement initiative was formed at Children's Hospital at Montefiore. We identified patient-, equipment-, and physician-related causes for case delays. Pareto charts, cause and effect diagrams, process flow mapping, and statistical process control charts were used for analysis. From June 2010 to December 2012, we were able to significantly decrease the first case endoscopy delay from an average of 17 to 10 minutes (P < .001), second case delay from 39 to 25 minutes (P = .01), third case delay from 61 to 45 minutes (P = .05), and fourth case delay from 79 to 51 minutes (P = .05). Total delay time decreased from 196 to 131 minutes, resulting in a reduction of 65 minutes (P = .02). From June 2010 to August 2011 (preintervention period), an average of 36% of first endoscopy cases started within 5 minutes, 51% within 10 minutes, and 61% within 15 minutes of the scheduled time. From September 2011 to December 2012 (postintervention period), the percentage of cases starting within 5 minutes, 10 minutes, and 15 minutes increased to 47% (P = .07), 61% (P = .04), and 79% (P = .01), respectively. Applying quality improvement methods and tools helped improve pediatric endoscopy timeliness and significantly decreased total delays.

  15. Implementation of a virtual laryngoscope system using efficient reconstruction algorithms.

    Science.gov (United States)

    Luo, Shouhua; Yan, Yuling

    2009-08-01

    Conventional fiberoptic laryngoscope may cause discomfort to the patient and in some cases it can lead to side effects that include perforation, infection and hemorrhage. Virtual laryngoscopy (VL) can overcome this problem and further it may lower the risk of operation failures. Very few virtual endoscope (VE) based investigations of the larynx have been described in the literature. CT data sets from a healthy subject were used for the VL studies. An algorithm of preprocessing and region-growing for 3-D image segmentation is developed. An octree based approach is applied in our VL system which facilitates a rapid construction of iso-surfaces. Some locating techniques are used for fast rendering and navigation (fly-through). Our VL visualization system provides for real time and efficient 'fly-through' navigation. The virtual camera can be arranged so that it moves along the airway in either direction. Snap shots were taken during fly-throughs. The system can automatically adjust the direction of the virtual camera and prevent collisions of the camera and the wall of the airway. A virtual laryngoscope (VL) system using OpenGL (Open Graphics Library) platform for interactive rendering and 3D visualization of the laryngeal framework and upper airway is established. OpenGL is supported on major operating systems and works with every major windowing system. The VL system runs on regular PC workstations and was successfully tested and evaluated using CT data from a normal subject.

  16. Review of musculoskeletal injuries and prevention in the endoscopy practitioner.

    Science.gov (United States)

    Harvin, Glenn

    2014-08-01

    Practitioners of endoscopy often experience musculoskeletal pain and injury (most often in the back, neck, shoulders, hands, wrists, and thumbs) that are associated with the minute and repetitive strain that is placed on these areas during endoscopic procedures. This review of the current documentation of endoscopy-related pain and injuries among practitioners finds that such problems are widespread and specific in kind as well as strongly correlated with high procedure volume and procedure duration. Research on the nature and impact of cumulative trauma and overuse syndromes in other professions such as dentistry, pianists, production labor, and athletics is brought to bear on the work of the endoscopist. A more thorough understanding of the nature and prevalence of work-related pain and injury sustained by endoscopists should inform further development of ergonomic practices and equipment design. This article reviews current recommendations for ergonomic design in the endoscopy procedure space and finds that reported compliance with those recommendations is quite low. Strategies for the management of the risk of musculoskeletal injuries related to the practice of endoscopy include compliance with currently recommended ergonomic practices, education of trainees in ergonomic technique when practicing endoscopy, and research toward the modification and development of more ergonomic endoscopes and procedure spaces.

  17. Chromoendoscopy and magnification endoscopy in Barrett's esophagus.

    Science.gov (United States)

    Connor, Michael J; Sharma, Prateek

    2003-04-01

    Chromoendoscopy and magnification endoscopy appear to be a valuable adjuncts for the detection and classification of BE. These techniques may also prove to be useful aids in surveillance protocols for identifying dysplastic epithelium or early cancer within a segment of BE. Ideally, the use of these techniques would enable the endoscopist to rule in or out the presence of IM and of dysplastic or cancerous epithelium by obtaining only a minimal number of targeted biopsy specimens, or potentially performing no biopsies at all. This could transform upper endoscopy into a much more effective screening and surveillance tool for BE. Several problems currently exist for the use of chromoendoscopy for BE. Results of studies reporting the accuracy of chromoendoscopy remain mixed,and are likely explained by the wide range of techniques and materials used in the investigations. Staining adds several steps, and likely several minutes, to an upper endoscopy. Staining within the esophagus is often patchy and uneven. In addition, poor spraying technique exaggerates the irregular uptake by the mucosa. There is a high false-positive rate when staining gastric-type epithelium and denuded epithelium. Areas of dysplasia or cancer may take up stain in an irregular manner, or may not stain at all. Chromoendoscopy is a relatively new technique in the management of BE and depends on the skill and experience of the endoscopist. Magnification, however, only allows the endoscopist to observe small areas of mucosa at a time, increasing the overall complexity and length of the procedure. The learning curve for this procedure is relatively short, however, and endoscopists can usually become proficient in the technique quickly. Currently, the greatest body of literature exists concerning the use of methylene blue for diagnosing BE. At the present time, chromoendoscopy and magnification endoscopy appear to be most beneficial in detecting IM in short segments of esophageal columnar

  18. The European Society of Gastrointestinal Endoscopy Quality Improvement Initiative: developing performance measures.

    Science.gov (United States)

    Rutter, Matthew D; Senore, Carlo; Bisschops, Raf; Domagk, Dirk; Valori, Roland; Kaminski, Michal F; Spada, Cristiano; Bretthauer, Michael; Bennett, Cathy; Bellisario, Cristina; Minozzi, Silvia; Hassan, Cesare; Rees, Colin; Dinis-Ribeiro, Mário; Hucl, Tomas; Ponchon, Thierry; Aabakken, Lars; Fockens, Paul

    2016-02-01

    The European Society of Gastrointestinal Endoscopy (ESGE) and United European Gastroenterology (UEG) have a vision to create a thriving community of endoscopy services across Europe, collaborating with each other to provide high quality, safe, accurate, patient-centered and accessible endoscopic care. Whilst the boundaries of what can be achieved by advanced endoscopy are continually expanding, we believe that one of the most fundamental steps to achieving our goal is to raise the quality of everyday endoscopy. The development of robust, consensus- and evidence-based key performance measures is the first step in this vision. ESGE and UEG have identified quality of endoscopy as a major priority. This paper explains the rationale behind the ESGE Quality Improvement Initiative and describes the processes that were followed. We recommend that all units develop mechanisms for audit and feedback of endoscopist and service performance using the ESGE performance measures that will be published in future issues of this journal over the next year. We urge all endoscopists and endoscopy services to prioritize quality and to ensure that these performance measures are implemented and monitored at a local level, so that we can provide the highest possible care for our patients.

  19. Usefulness of post-mortem ophthalmological endoscopy during forensic autopsy: a case report.

    Science.gov (United States)

    Tsujinaka, Masatake; Akaza, Kayoko; Nagai, Atsushi; Nakamura, Isao; Bunai, Yasuo

    2005-01-01

    Post-mortem intraocular findings in two autopsy cases with traumatic intracranial haemorrhage were obtained using an ophthalmological endoscope. The endoscopy results clearly revealed the presence of intraocular haemorrhages and papilledema caused by intracranial haemorrhage. Post-mortem ophthalmological endoscopy offers several benefits. First, post-mortem intraocular findings can be directly observed in corpses with post-mortem clouding of the cornea. Secondly, the endoscopy only requires a 0.9 mm incision in the sclera and does not require the removal of the eye from the corpse, a procedure that should be avoided for ethical and cosmetic reasons. Thus, post-mortem opthalmological endoscopy is a useful method for obtaining intraocular findings in autopsies.

  20. Augmented Virtuality: A Real-time Process for Presenting Real-world Visual Sensory Information in an Immersive Virtual Environment for Planetary Exploration

    Science.gov (United States)

    McFadden, D.; Tavakkoli, A.; Regenbrecht, J.; Wilson, B.

    2017-12-01

    Virtual Reality (VR) and Augmented Reality (AR) applications have recently seen an impressive growth, thanks to the advent of commercial Head Mounted Displays (HMDs). This new visualization era has opened the possibility of presenting researchers from multiple disciplines with data visualization techniques not possible via traditional 2D screens. In a purely VR environment researchers are presented with the visual data in a virtual environment, whereas in a purely AR application, a piece of virtual object is projected into the real world with which researchers could interact. There are several limitations to the purely VR or AR application when taken within the context of remote planetary exploration. For example, in a purely VR environment, contents of the planet surface (e.g. rocks, terrain, or other features) should be created off-line from a multitude of images using image processing techniques to generate 3D mesh data that will populate the virtual surface of the planet. This process usually takes a tremendous amount of computational resources and cannot be delivered in real-time. As an alternative, video frames may be superimposed on the virtual environment to save processing time. However, such rendered video frames will lack 3D visual information -i.e. depth information. In this paper, we present a technique to utilize a remotely situated robot's stereoscopic cameras to provide a live visual feed from the real world into the virtual environment in which planetary scientists are immersed. Moreover, the proposed technique will blend the virtual environment with the real world in such a way as to preserve both the depth and visual information from the real world while allowing for the sensation of immersion when the entire sequence is viewed via an HMD such as Oculus Rift. The figure shows the virtual environment with an overlay of the real-world stereoscopic video being presented in real-time into the virtual environment. Notice the preservation of the object

  1. Upper Gastro-Intestinal Endoscopy in Port Harcourt, Nigeria: An Audit

    African Journals Online (AJOL)

    Background: Accurate diagnosis of disease conditions using laboratory, imaging or endoscopic investigation is essential for appropriate treatment. There is paucity of data on upper GI endoscopy in Port-Harcourt. This audit of our early experience is intended to provide data on the pattern of endoscopy findings which is ...

  2. Impact of educational intervention on the inter-rater agreement of nasal endoscopy interpretation

    Science.gov (United States)

    Colley, Patrick; Mace, Jess C.; Schaberg, Madeleine R.; Smith, Timothy L.; Tabaee, Abtin

    2015-01-01

    OBJECTIVE Nasal endoscopy is integral to the evaluation of sinonasal disorders. However, prior studies have shown significant variability in the inter-rater agreement of nasal endoscopy interpretation amongst practicing rhinologists. The objective of the current study is to evaluate the inter-rater agreement of nasal endoscopy amongst otolaryngology residents from a single training program at baseline and following an educational intervention. METHODS 11 otolaryngology residents completed nasal endoscopy grading forms for 8 digitally recorded nasal endoscopic examinations. An instructional lecture reviewing nasal endoscopy interpretation was subsequently provided. The residents then completed grading forms for 8 different nasal endoscopic examinations. Inter-rate agreement amongst residents for the pre- and post-lecture videos was calculated using the unweighted Fleiss’ kappa statistic (Kf) and intra-class correlation agreement (ICC). RESULTS Inter-rater agreement improved from a baseline level of fair (Kf range 0.268–0.383) to a post-educational level of moderate (Kf range 0.401–0.547) for nasal endoscopy findings of middle meatus mucosa, middle turbinate mucosa, middle meatus discharge, sphenoethmoid recess mucosa, sphenoethmoid recess discharge and atypical lesions (ICC, pendoscopy interpretation amongst otolaryngology residents. The inter-rater agreement for the majority of the characteristics that were evaluated improved after educational intervention. Further study is needed to improve nasal endoscopy interpretation. PMID:25781864

  3. Sedation and Monitoring in the Pediatric Patient during Gastrointestinal Endoscopy.

    Science.gov (United States)

    Chung, Hyun Kee; Lightdale, Jenifer R

    2016-07-01

    Sedation is a fundamental component of pediatric gastrointestinal procedures. The 2 main types of sedation for pediatric endoscopy remain general anesthesia and procedural sedation. Although anesthesiologist-administered sedation protocols are more common, there is no ideal regimen for endoscopy in children. This article discusses specific levels of sedation for endoscopy as well as various regimens that can be used to achieve each. Risks and considerations that may be specific to performing gastrointestinal procedures in children are reviewed. Finally, potential future directions for sedation and monitoring that may change the practice of pediatric gastroenterology and ultimately patient outcomes are examined. Copyright © 2016 Elsevier Inc. All rights reserved.

  4. Endoscopy and sedation: an inseparable binomial for the gastroenterologist.

    Science.gov (United States)

    Crespo, Javier; Terán, Álvaro

    2018-04-01

    The development of endoscopy and its increasing demand among the population have led to a growing need for propofol-based sedation techniques. Benefit is indisputable for both patients and endoscopists, but some aspects require considering the "who" and "how" of sedation as related to safety and health care costs. Propofol is first-choice in endoscopy for the European Society of Gastrointestinal Endoscopy because of its fast onset of action and short half-life, and many reports exist on its safety when used by gastroenterologists rather than anesthesiologists. In this issue of REED several originals support the efficiency and safety of propofol even for complex, high-risk, or protracted procedures such as endoscopic retrograde cholangiopancreatography (ERCP) and enteroscopy. Propofol may be safely and effectively administered by a team with specific skills acquired through education and using a specific procedure. However, difficulties arise in real-world clinical practice that preclude such training, which in Spain should be included in the MIR (médico interno residente) specialization program curriculum. The Comisión Nacional de Digestivo (Spanish National Commission on Digestive Diseases), sensitive to this training gap, has included in their latest version of the MIR program (under assessment) four additional competences, with number 145 (training in deep sedation) being most relevant here. In addition, the Spanish Society of Gastrointestinal Endoscopy (SEED) has invested significant efforts in sedation training, with over 50 courses on sedation for endoscopists and nurses. Continuing education and training in this field (for instance, refresher courses on advanced cardiopulmonary resuscitation) should be a goal for all endoscopy units. Because of the diversity found among hospitals, with single or multiple endoscopy rooms, efforts should be made to persuade those in charge of gastroenterology and anesthesiology departments to establish the necessary care

  5. Upper gastrointestinal endoscopy in children: The Lagos University Teaching Hospital experience

    Directory of Open Access Journals (Sweden)

    Oluwafunmilayo Funke Adeniyi

    2016-12-01

    Full Text Available Background. Paediatric endoscopy is now standard care in the developed world for the management of gastrointestinal (GI disorders. However, in developing countries endoscopy remains an underutilised tool. Objective. To determine the indications and the spectrum of endoscopic findings in children seen at the Lagos University Teaching Hospital, Nigeria. Methods. The indications for upper GI endoscopy and endoscopic findings in children ≤16 years old, referred for the procedure from June 2013 to June 2016, were documented. The endoscopic yield in these children was also determined. Results. In total 71 children were referred for upper GI endoscopy during the study period. There were 35 boys and 36 girls aged 3 months to 16 years. The indications for upper endoscopy were recurrent abdominal pain in 37 (52.1%, upper GI bleeding in 17 (23.9%, recurrent vomiting in 7 (9.9%, dyspepsia in 5 (7.0, heartburn in 2 (2.8%, dysphagia in 1 (1.4, portal hypertension in 1 (1.4 and ingestion of corrosives in 1 (1.4% of the subjects. Endoscopic findings were as follows: gastritis 19 (26.8%, hiatus hernia in 13 (18.3%, gastric erosions in 12 (16.9%, oesophageal varices 6 (8.4%, duodenitis in 4 (5.6%, gastric ulcer in 3 (4.2%, gastric polyp in 2 (2.8%. The overall endoscopic yield was 60.2%. Conclusion. There is a need to increase the awareness of the role of paediatric endoscopy in the diagnosis and treatment of GI disorders in developing countries. Recurrent abdominal pain still remains a relevant indication for the procedure. The need to develop training programmes for paediatric endoscopy and paediatric gastroenterology in general in developing countries cannot be overemphasised.

  6. Non-technical skills and gastrointestinal endoscopy: a review of the literature.

    Science.gov (United States)

    Hitchins, Charlotte R; Metzner, Magdalena; Edworthy, Judy; Ward, Catherine

    2018-04-01

    Non-technical skills (NTS) have gained increasing recognition in recent years for their role in safe, effective team performance in healthcare. Gastrointestinal endoscopy is a procedure-based specialty with rapidly advancing technology, significant operational pressures and rapidly changing 'teams of experts'. However, to date there has been little focus on the effect of NTS in this field. This review aims to examine the existing literature on NTS in gastrointestinal endoscopy and identify areas for further research. A systematic search of MEDLINE, Embase, Cochrane Library, PsychINFO, CINAHL Plus and PubMed databases was performed using search terms Non-Technical Skills, Team Performance or Team Skills, and Endoscopy, Colonoscopy, OGD, Gastroscopy, Endoscopic Retrograde Cholangio-Pancreatography or Endoscopic Ultrasound. Eighteen relevant publications were found. NTS are deemed an essential component of practice, but so far there is little evidence of their integration into training or competency assessment. Those studies examining the effects of NTS and team training in endoscopy are small and have variable outcome measures with limited evidence of improvement in skills or clinical outcomes. NTS assessment in endoscopy is in its early phases with a few tools in development. The current literature on NTS in gastrointestinal endoscopy is limited. NTS, however, are deemed an essential component of practice, with potential positive effects on team performance and clinical outcomes. A validated reliable tool would enable evaluation of training and investigation into the effects of NTS on outcomes. There is a clear need for further research in this field.

  7. Risk factors for nasal bleeding in patients undergoing transnasal gastrointestinal endoscopy

    Directory of Open Access Journals (Sweden)

    Mitsuyo Mieda

    2018-05-01

    Full Text Available Transnasal endoscopy is widely used in screening for upper gastrointestinal lesions because of less associated pain. Nasal bleeding is the most severe adverse effect, but specific risk factors have not been identified. The aim of this study is to identify risk factors for nasal bleeding during transnasal endoscopy. Nasal bleeding occurred in 160/3035 (5.3% of patients undergoing transnasal endoscopy as part of health checkups. Patient data were retrospectively evaluated including anthropometric, medical, and life-style parameters with multiple logistic regression analysis. Multiple logistic regression revealed that nasal bleeding was significantly associated with age in decades [odds ratio/10 years 0.78, 95% confidence interval (CI 0.63–0.97, p = 0.027], female gender (2.15, 95% CI 1.48–3.12, p < 0.001, a history of previous upper gastrointestinal endoscopy (0.55, 95% CI 0.36–0.82, p = 0.004, and chronic/allergic rhinitis (0.60, 95% CI 0.36–0.98, p = 0.043. Other factors including the use of antiplatelet and/or anticoagulant drugs were not significantly associated with nasal bleeding. Female and young patients are significantly associated with an increased risk of bleeding from transnasal endoscopy, but antiplatelet and/or anticoagulant medications and a history of chronic/allergic rhinitis may not be associated. Keywords: Transnasal endoscopy, Nasal bleeding, Risk factors

  8. [The role of endoscopy in gastroenteropancreatic neuroendocrine tumors].

    Science.gov (United States)

    Magno, L; Sivero, L; Napolitano, V; Ruggiero, S; Fontanarosa, G; Massa, S

    2010-01-01

    Versione italiana Riassunto: Il ruolo dell'endoscopia nei tumori neuroendocrini gastroenteropancreatici. L. Magno, L. Sivero, V. Napolitano, S. Ruggiero, G. Fontanarosa, S. Massa I tumori neuroendocrini (NET) gastro-entero-pancreatici (GEP) sono neoplasie rare che originano dalle cellule neuroendocrine del tubo digerente e del pancreas. L'endoscopia digestiva e l'ecoendoscopia rivestono un ruolo importante nella diagnosi, stadiazione e sorveglianza dei pazienti con NET. Inoltre, in casi selezionati, le tecniche endoscopiche operative consentono il trattamento di queste neoplasie in fase precoce. English version Summary: The role of endoscopy in gastroenteropancreatic neuroendocrine tumors. L. Magno, L. Sivero, V. Napolitano, S. Ruggiero, G. Fontanarosa, S. Massa Gastroenteropancreatic (GEP) neuroendocrine tumors (NET) are rare neoplasia arisen from neuroendocrine cells present in the gut mucosa and pancreas. Digestive endoscopy and endoscopic ultrasonography play a relevant role in NET diagnosis, stadiation and surveillance. Moreover, in selected patients, surgical endoscopy allows the tratment of these cancers at an early stage.

  9. The application value of capsule endoscopy in diagnosing small intestinal carcinoma

    Directory of Open Access Journals (Sweden)

    Xiaohuan Li

    2018-01-01

    Conclusion: Capsule endoscopy demonstrated a high diagnostic value for various small bowel diseases, including both tumor and inflammatory lesions. Given its simplicity, safety, and reliability, capsule endoscopy was an important examination tool for the diagnosis of small bowel diseases.

  10. Building Virtual Mars

    Science.gov (United States)

    Abercrombie, S. P.; Menzies, A.; Goddard, C.

    2017-12-01

    Virtual and augmented reality enable scientists to visualize environments that are very difficult, or even impossible to visit, such as the surface of Mars. A useful immersive visualization begins with a high quality reconstruction of the environment under study. This presentation will discuss a photogrammetry pipeline developed at the Jet Propulsion Laboratory to reconstruct 3D models of the surface of Mars using stereo images sent back to Earth by the Curiosity Mars rover. The resulting models are used to support a virtual reality tool (OnSight) that allows scientists and engineers to visualize the surface of Mars as if they were standing on the red planet. Images of Mars present challenges to existing scene reconstruction solutions. Surface images of Mars are sparse with minimal overlap, and are often taken from extremely different viewpoints. In addition, the specialized cameras used by Mars rovers are significantly different than consumer cameras, and GPS localization data is not available on Mars. This presentation will discuss scene reconstruction with an emphasis on coping with limited input data, and on creating models suitable for rendering in virtual reality at high frame rate.

  11. Sketchy Rendering for Information Visualization

    NARCIS (Netherlands)

    Wood, Jo; Isenberg, Petra; Isenberg, Tobias; Dykes, Jason; Boukhelifa, Nadia; Slingsby, Aidan

    2012-01-01

    We present and evaluate a framework for constructing sketchy style information visualizations that mimic data graphics drawn by hand. We provide an alternative renderer for the Processing graphics environment that redefines core drawing primitives including line, polygon and ellipse rendering. These

  12. Monitoring of Intracranial Pressure During Intracranial Endoscopy

    Directory of Open Access Journals (Sweden)

    Rajeev Kumar

    2013-08-01

    Full Text Available Background: Intracranial endoscopy is a minimum invasive procedure, which reduces trauma to the brain, is cost-effective, and carries a shortened hospital stay with an improved postoperative outcome. Objective: To monitor intracranial pressure changes during intracranial endoscopy among children and adults under general anesthesia/sedation, and to compare the intracranial pressure changes between children and adults receiving general anesthesia and among adults receiving general anesthesia and sedation. Methods: The present cross-sectional study was conducted in one of the tertiary care hospitals of Lucknow. This was carried out in the department of neurosurgery from January 2008 to December 2008. Patients who were not fit for general anesthesia received local anesthesia under sedation. Patients participating in the study were divided into three groups. Intracranial pressure was recorded at specific intervals. Parametric data were subjected to statistical analysis using a student\\s t test. Result: A total of 70 patients were undergoing intracranial endoscopy under general anesthesia during the study period. In both groups A and B, intracranial pressure increases the maximum during inflation of the balloon. In group C, all the variations in ICP were found to be statistically significant. In the comparison of intracranial pressure changes between groups A and B, no significant difference was found. All correlations in the comparison of groups B and C were found to be statistically significant (p< 0.001. Conclusion: There is a need for continuous intraoperative monitoring of ICP intracranial endoscopy, because ICP increases in various stages of the procedure, which can be detrimental to the perfusion of the brain. [Arch Clin Exp Surg 2013; 2(4.000: 240-245

  13. Delayed bleeding and hemorrhage of mucosal defects after gastric endoscopic submucosal dissection on second-look endoscopy.

    Science.gov (United States)

    Ono, Shoko; Ono, Masayoshi; Nakagawa, Manabu; Shimizu, Yuichi; Kato, Mototsugu; Sakamoto, Naoya

    2016-04-01

    Although second-look endoscopy is performed within several days after gastric endoscopic submucosal dissection (ESD), there has been no evidence supporting the usefulness of the intervention. We investigated the relationship between delayed bleeding and hemorrhage of mucosal defects after ESD on second-look endoscopy and analyzed risk factors of active bleeding on second-look endoscopy. A total of 441 consecutive ESD cases with gastric cancer or adenoma were retrospectively analyzed. Second-look endoscopy was performed in the morning after the day of ESD. Bleeding of mucosal defects on second-look endoscopy was classified according to the Forrest classification, and active bleeding was defined as Forrest Ia or Ib. Delayed bleeding was defined as hematemesis or melena after second-look endoscopy. A total of 406 second-look endoscopies were performed, and delayed bleeding occurred in 11 patients. The incidence rate of delayed bleeding after second-look endoscopy in patients with Forrest Ia or Ib was significantly higher than that in patients with Forrest IIa, IIb or III (7.69 vs. 2.02 %, p 35 mm, the odds ratio of active bleeding on second-look endoscopy was 1.9. Active bleeding of mucosal defects on second-look endoscopy is a risk factor for delayed bleeding.

  14. Virtual airway simulation to improve dexterity among novices performing fibreoptic intubation.

    Science.gov (United States)

    De Oliveira, G S; Glassenberg, R; Chang, R; Fitzgerald, P; McCarthy, R J

    2013-10-01

    We developed a virtual reality software application (iLarynx) using built-in accelerometer properties of the iPhone(®) or iPad(®) (Apple Inc., Cupertino, CA, USA) that mimics hand movements for the performance of fibreoptic skills. Twenty novice medical students were randomly assigned to virtual airway training with the iLarynx software or no additional training. Eight out of the 10 subjects in the standard training group had at least one failed (> 120 s) attempt compared with two out of the 10 participants in the iLarynx group (p = 0.01). There were a total of 24 failed attempts in the standard training group and four in the iLarynx group (p < 0.005). Cusum analysis demonstrated continued group improvement in the iLarynx, but not in the standard training group. Virtual airway simulation using freely available software on a smartphone/tablet device improves dexterity among novices performing upper airway endoscopy. © 2013 The Association of Anaesthetists of Great Britain and Ireland.

  15.  Cost-effectiveness of medicine vs. endoscopy for dyspeptic patients

    DEFF Research Database (Denmark)

    Kjeldsen, Hans Christian; Lauritzen, Torsten; Christensen, Bo

      Background: Decision analyses conclude that empirical anti-secretory therapy is more cost-effective than endoscopy for managing patients with dyspepsia however RCTs including economic evaluation come to diverging results Aim: to compare the cost-effectiveness of two strategies for management.......   Results The incremental cost effectiveness (CE) ratio for one day free of dyspeptic symptoms using the endoscopy strategy was €/day 300 compared with the PPI strategy. The incremental CE ratio for one patient free of dyspeptic symptoms after one year using the endoscopy strategy was € 13,600 based....... The empirical PPI strategy was hence the more cost-effective strategy for managing patients with dyspepsia in general practice especially if reflux was the predominant symptom.  ...

  16. Upper gastrointestinal endoscopy at the korle bu teaching hospital, accra, ghana.

    Science.gov (United States)

    Aduful, Hk; Naaeder, Sb; Darko, R; Baako, Bn; Clegg-Lamptey, Jna; Nkrumah, Kn; Adu-Aryee, Na; Kyere, M

    2007-03-01

    To study the indications for endoscopy, the endoscopic diagnosis and other lessons learnt. A retrospective and prospective audit of all upper gastrointestinal endoscopies performed in the Endoscopy Unit of the Korle-Bu Teaching Hospital from January 1995 to December 2002 was performed. A total of 6977 patients, 3777 males and 3200 females with age range 1 year 8 months to 93 years were endoscoped. The mean age of males was 43.5 +/- 0.5 and females 43.7 +/- 0.6 years. Epigastric pain (42.5%), dyspepsia (32.8%) and haematemesis and melaena (14.2%) were the commonest reasons for endoscopy. Chronic duodenal ulcer (19.6%), acute gastritis (12.7%), duodenitis (10.2%), oesophagitis (7.5%) were the commonest diagnoses. Normal endoscopy was reported in 41.1% patients, and was higher in the younger age group compared to the older (R = 0.973, P<0.001). Nine hundred and ninety (14.2%) patients were endoscoped for haematemesis and melaena of which chronic duodenal ulcer (32.1%), gastritis/gastric erosions (12.8%), oesophageal varices (9.8%), carcinoma of the stomach (6.4%), and duodenitis (4.2%), were the commonest causes. No lesion was found in 20.6% of these patients. Urease test was positive in 75% of all biopsy specimen and 85% in chronic duodenal ulcer, gastritis and duodenitis. The normal endoscopy rate is high and needs to be reduced in order to help prolong the lives of the endoscopes. Chronic duodenal ulcer is usually associated with H. pylori infection and is the commonest cause of upper gastrointestinal bleeding.

  17. Cerebral gas embolism due to upper gastrointestinal endoscopy.

    Science.gov (United States)

    ter Laan, Mark; Totte, Erik; van Hulst, Rob A; van der Linde, Klaas; van der Kamp, Wim; Pierie, Jean-Pierre E

    2009-07-01

    Cerebral gas embolism as a result of upper gastrointestinal endoscopy is a rare complication and bares a high morbidity. A patient is presented who underwent an upper endoscopy for evaluation of a gastric-mediastinal fistula after subtotal oesophagectomy and gastric tube reconstruction because of oesophageal cancer. During the procedure, cerebral gas emboli developed resulting in an acute left-sided hemiparesis. After hyperbaric oxygen therapy, the patient recovered almost completely. The aetiology and treatment is discussed based on the reviewed literature. Once cerebral gas emboli are recognized, patient outcome can be improved by hyperbaric oxygen therapy.

  18. Do technical parameters affect the diagnostic accuracy of virtual bronchoscopy in patients with suspected airways stenosis?

    International Nuclear Information System (INIS)

    Jones, Catherine M.; Athanasiou, Thanos; Nair, Sujit; Aziz, Omer; Purkayastha, Sanjay; Konstantinos, Vlachos; Paraskeva, Paraskevas; Casula, Roberto; Glenville, Brian; Darzi, Ara

    2005-01-01

    Purpose: Virtual bronchoscopy has gained popularity over the past decade as an alternative investigation to conventional bronchoscopy in the diagnosis, grading and monitoring of airway disease. The effect of technical parameters on diagnostic outcome from virtual bronchoscopy has not been determined. This meta-analysis aims to estimate accuracy of virtual compared to conventional bronchoscopy in patients with suspected airway stenosis, and evaluate the influence of technical parameters. Materials and methods: A MEDLINE search was used to identify relevant published studies. The primary endpoint was the 'correct diagnosis' of stenotic lesions on virtual compared to conventional bronchoscopy. Secondary endpoints included the effects of the technical parameters (pitch, collimation, reconstruction interval, rendering method, and scanner type), and date of publication on the diagnostic accuracy of virtual bronchoscopy. Results: Thirteen studies containing 454 patients were identified. Meta-analysis showed good overall diagnostic performance with 85% calculated pooled sensitivity (95% CI 77-91%), 87% specificity (95% CI 81-92%) and area under the curve (AUC) of 0.947. Subgroups included collimation of 3 mm or more (AUC 0.948), pitch of 1 (AUC 0.955), surface rendering technique (AUC 0.935), and reconstruction interval of more than 1.25 mm (AUC 0.914). There was no significant difference in accuracy accounting for publication date, scanner type or any of the above variables. Weighted regression analysis confirmed none of these variables could significantly account for study heterogeneity. Conclusion: Virtual bronchoscopy performs well in the investigation of patients with suspected airway stenosis. Overall sensitivity and specificity and diagnostic odds ratio for diagnosis of airway stenosis were high. The effects of pitch, collimation, reconstruction interval, rendering technique, scanner type, and publication date on diagnostic accuracy were not significant

  19. Deep Learning in Gastrointestinal Endoscopy.

    Science.gov (United States)

    Patel, Vivek; Armstrong, David; Ganguli, Malika; Roopra, Sandeep; Kantipudi, Neha; Albashir, Siwar; Kamath, Markad V

    2016-01-01

    Gastrointestinal (GI) endoscopy is used to inspect the lumen or interior of the GI tract for several purposes, including, (1) making a clinical diagnosis, in real time, based on the visual appearances; (2) taking targeted tissue samples for subsequent histopathological examination; and (3) in some cases, performing therapeutic interventions targeted at specific lesions. GI endoscopy is therefore predicated on the assumption that the operator-the endoscopist-is able to identify and characterize abnormalities or lesions accurately and reproducibly. However, as in other areas of clinical medicine, such as histopathology and radiology, many studies have documented marked interobserver and intraobserver variability in lesion recognition. Thus, there is a clear need and opportunity for techniques or methodologies that will enhance the quality of lesion recognition and diagnosis and improve the outcomes of GI endoscopy. Deep learning models provide a basis to make better clinical decisions in medical image analysis. Biomedical image segmentation, classification, and registration can be improved with deep learning. Recent evidence suggests that the application of deep learning methods to medical image analysis can contribute significantly to computer-aided diagnosis. Deep learning models are usually considered to be more flexible and provide reliable solutions for image analysis problems compared to conventional computer vision models. The use of fast computers offers the possibility of real-time support that is important for endoscopic diagnosis, which has to be made in real time. Advanced graphics processing units and cloud computing have also favored the use of machine learning, and more particularly, deep learning for patient care. This paper reviews the rapidly evolving literature on the feasibility of applying deep learning algorithms to endoscopic imaging.

  20. 3D Flow visualization in virtual reality

    Science.gov (United States)

    Pietraszewski, Noah; Dhillon, Ranbir; Green, Melissa

    2017-11-01

    By viewing fluid dynamic isosurfaces in virtual reality (VR), many of the issues associated with the rendering of three-dimensional objects on a two-dimensional screen can be addressed. In addition, viewing a variety of unsteady 3D data sets in VR opens up novel opportunities for education and community outreach. In this work, the vortex wake of a bio-inspired pitching panel was visualized using a three-dimensional structural model of Q-criterion isosurfaces rendered in virtual reality using the HTC Vive. Utilizing the Unity cross-platform gaming engine, a program was developed to allow the user to control and change this model's position and orientation in three-dimensional space. In addition to controlling the model's position and orientation, the user can ``scroll'' forward and backward in time to analyze the formation and shedding of vortices in the wake. Finally, the user can toggle between different quantities, while keeping the time step constant, to analyze flow parameter relationships at specific times during flow development. The information, data, or work presented herein was funded in part by an award from NYS Department of Economic Development (DED) through the Syracuse Center of Excellence.

  1. Mental vision: a computer graphics platform for virtual reality, science and education

    OpenAIRE

    Peternier, Achille

    2009-01-01

    Despite the wide amount of computer graphics frameworks and solutions available for virtual reality, it is still difficult to find a perfect one fitting at the same time the many constraints of research and educational contexts. Advanced functionalities and user-friendliness, rendering speed and portability, or scalability and image quality are opposite characteristics rarely found into a same approach. Furthermore, fruition of virtual reality specific devices like CAVEs or wearable systems i...

  2. Virtual environments for scene of crime reconstruction and analysis

    Science.gov (United States)

    Howard, Toby L. J.; Murta, Alan D.; Gibson, Simon

    2000-02-01

    This paper describes research conducted in collaboration with Greater Manchester Police (UK), to evalute the utility of Virtual Environments for scene of crime analysis, forensic investigation, and law enforcement briefing and training. We present an illustrated case study of the construction of a high-fidelity virtual environment, intended to match a particular real-life crime scene as closely as possible. We describe and evaluate the combination of several approaches including: the use of the Manchester Scene Description Language for constructing complex geometrical models; the application of a radiosity rendering algorithm with several novel features based on human perceptual consideration; texture extraction from forensic photography; and experiments with interactive walkthroughs and large-screen stereoscopic display of the virtual environment implemented using the MAVERIK system. We also discuss the potential applications of Virtual Environment techniques in the Law Enforcement and Forensic communities.

  3. Early Period Results and Clinical Characteristics of Upper Gastrointestinal Endoscopy in Sivrihisar State Hospital

    Directory of Open Access Journals (Sweden)

    Ozgur Turk

    2014-12-01

    Full Text Available Aim: Our aim was to identify the characteristics of the patient that performed upper gastrointestinal endoscopy in a new established endoscopy unit of a state hospital. We want to present the spectrum of gastrointestinal diseases in our hospitals region. Material and Method: We analyzed patients upper endoscopy results according to age, sex, complaints, clinical characteristics, type of anesthesia, and the necessity of biopsy. We reviewed 256 patients data between 2013 December-2014 July. All endoscopies were performed by same surgeon. Results: The highest complaint was epigastric pain (n=112, 43, 8%. Other complaints were followed as dyspepsia (n=84, 32.8%, heartburn (n=42, 16.4%, nausea (n=4, 1.6%, vomiting (n=2, 0.8%, dysphagia (n=6, 2.3%. We determined 218 gastritis (85.2%, 64 hiatal hernia (25%, 120 esophagitis (46.9%, 76 duodenitis (29.7%, 4 gastric ulcer (1.6%, 18 duodenal ulcers (7%, 20 bile reflux (7.8%, 26 Gastro esophageal reflux disease (GERD in patients (10.2%. 10 patients reported as normal (3.9%. Biopsy was performed in 186 of the patients. Discussion: Endoscopy can become an early diagnostic examination by increasing the availability of endoscopy. Also alarm symptoms should not be ignored and endoscopy should perform immediately in symptomatic patients. As an early result of upper gastrointestinal endoscopies that performed in this study; gastritis, esophagitis, duodenitis and hiatal hernia are common gastrointestinal diseases in our region.

  4. Data Content Protection for Virtual Libraries Heritage

    Directory of Open Access Journals (Sweden)

    Mihai DOINEA

    2016-01-01

    Full Text Available This paper presents aspects of digital content protection in virtual library systems. The legislation aspects are presented to better emphasize the need of new security mechanisms. Integrated library systems architecture is presented with focus on their main purpose, manipulating and rendering digital content to end-users. The cultural heritage stored in such systems is an important asset that needs to be protected against malicious manipulation. The characteristics of a smart virtual library, supported by an integrated library system, are analyzed and a security model is proposed for implementation, based on its particularities. The model aims to be an interface between the interactions of anonymous users with the Online Public Access Catalog of a virtual library that assures the protection of digital content. Conclusions are drawn to better support the idea of cultural persistence by the use of Information Systems.

  5. Polyp Detection and Segmentation from Video Capsule Endoscopy: A Review

    Directory of Open Access Journals (Sweden)

    V. B. Surya Prasath

    2016-12-01

    Full Text Available Video capsule endoscopy (VCE is used widely nowadays for visualizing the gastrointestinal (GI tract. Capsule endoscopy exams are prescribed usually as an additional monitoring mechanism and can help in identifying polyps, bleeding, etc. To analyze the large scale video data produced by VCE exams, automatic image processing, computer vision, and learning algorithms are required. Recently, automatic polyp detection algorithms have been proposed with various degrees of success. Though polyp detection in colonoscopy and other traditional endoscopy procedure based images is becoming a mature field, due to its unique imaging characteristics, detecting polyps automatically in VCE is a hard problem. We review different polyp detection approaches for VCE imagery and provide systematic analysis with challenges faced by standard image processing and computer vision methods.

  6. Videoscopic Heller Myotomy with Intraoperative Endoscopy Promotes Optimal Outcomes

    Science.gov (United States)

    Bloomston, Mark; Brady, Patrick

    2002-01-01

    Background and Objectives: Minimally invasive surgical techniques are applicable to achalasia, but the optimum approach to intraoperative assessment of adequacy of myotomy remains unestablished. We set out to show that videoscopic Heller myotomy with concurrent endoscopy ensures adequacy of myotomy while limiting postoperative clinically apparent reflux. Methods: Seventy-eight consecutive patients with achalasia underwent videoscopic Heller myotomy with concomitant endoscopy between 1992 and 1998. Fundoplication was not routinely undertaken. Results: Preoperative symptoms consisted of dysphagia (100%), emesis/regurgitation (68%), heartburn (58%), and postprandial chest pain (49%). Following myotomy, significant improvement (P Heller myotomy guides the extent and adequacy of myotomy. By utilizing a focused dissection with preservation of the natural antireflux mechanisms around the gastroesophageal junction and limiting the extent of myotomy along the cardia, postoperative reflux symptoms are minimized. We advocate concomitant endoscopy during Heller myotomy to guide myotomy and submit that routine fundoplication is clinically unnecessary. PMID:12113416

  7. A literature review of quality in lower gastrointestinal endoscopy from the patient perspective

    OpenAIRE

    Sewitch, Maida J; Gong, Shasha; Dubé, Catherine; Barkun, Alan; Hilsden, Robert; Armstrong, David

    2011-01-01

    BACKGROUND: Given the limited state of health care resources, increased demand for colorectal cancer (CRC) screening raises concerns about the quality of endoscopy services. Little is known about quality in colonoscopy and endoscopy from the patient perspective.OBJECTIVE: To systematically review the literature on quality that is relevant to patients who require colonoscopy or endoscopy services.METHODS: A systematic PubMed search was performed on articles that were published between January ...

  8. An Optimization Method for Virtual Globe Ocean Surface Dynamic Visualization

    Directory of Open Access Journals (Sweden)

    HUANG Wumeng

    2016-12-01

    Full Text Available The existing visualization method in the virtual globe mainly uses the projection grid to organize the ocean grid. This special grid organization has the defects in reflecting the difference characteristics of different ocean areas. The method of global ocean visualization based on global discrete grid can make up the defect of the projection grid method by matching with the discrete space of the virtual globe, so it is more suitable for the virtual ocean surface simulation application.But the available global discrete grids method has many problems which limiting its application such as the low efficiency of rendering and loading, the need of repairing grid crevices. To this point, we propose an optimization for the global discrete grids method. At first, a GPU-oriented multi-scale grid model of ocean surface which develops on the foundation of global discrete grids was designed to organize and manage the ocean surface grids. Then, in order to achieve the wind-drive wave dynamic rendering, this paper proposes a dynamic wave rendering method based on the multi-scale ocean surface grid model to support real-time wind field updating. At the same time, considering the effect of repairing grid crevices on the system efficiency, this paper presents an efficient method for repairing ocean surface grid crevices based on the characteristics of ocean grid and GPU technology. At last, the feasibility and validity of the method are verified by the comparison experiment. The experimental results show that the proposed method is efficient, stable and fast, and can compensate for the lack of function of the existing methods, so the application range is more extensive.

  9. Transform coding for hardware-accelerated volume rendering.

    Science.gov (United States)

    Fout, Nathaniel; Ma, Kwan-Liu

    2007-01-01

    Hardware-accelerated volume rendering using the GPU is now the standard approach for real-time volume rendering, although limited graphics memory can present a problem when rendering large volume data sets. Volumetric compression in which the decompression is coupled to rendering has been shown to be an effective solution to this problem; however, most existing techniques were developed in the context of software volume rendering, and all but the simplest approaches are prohibitive in a real-time hardware-accelerated volume rendering context. In this paper we present a novel block-based transform coding scheme designed specifically with real-time volume rendering in mind, such that the decompression is fast without sacrificing compression quality. This is made possible by consolidating the inverse transform with dequantization in such a way as to allow most of the reprojection to be precomputed. Furthermore, we take advantage of the freedom afforded by off-line compression in order to optimize the encoding as much as possible while hiding this complexity from the decoder. In this context we develop a new block classification scheme which allows us to preserve perceptually important features in the compression. The result of this work is an asymmetric transform coding scheme that allows very large volumes to be compressed and then decompressed in real-time while rendering on the GPU.

  10. Abdominal compression during endoscopy (the Bolster technique) demonstrates hidden Schatzki rings (with videos).

    Science.gov (United States)

    Jouhourian, Caroline; Bonis, Peter A; Guelrud, Moises

    2016-05-01

    Schatzki rings are found in the distal esophagus, are associated with hiatal hernias, and present with intermittent dysphagia to solid foods. They can be identified by radiology (GI series or barium swallow studies) or endoscopy. Rings are not always visualized during endoscopy in patients in whom they are suspected clinically. The Bolster technique involves application of epigastric abdominal pressure, which offers the potential to reveal a Schatzki ring that is otherwise obscured within a reduced hiatal hernia. The aim of this study was to determine whether the Bolster technique improves endoscopic detection of Schatzki rings. We reviewed 30 symptomatic patients with a history of a Schatzki ring in a tertiary care center. The Bolster technique was applied to patients in whom the ring was not visible during standard endoscopy. The main outcome measurement was identification of the Schatzki ring after the Bolster technique. A Schatzki ring was visible during standard endoscopy in 26 of the 30 patients. In the remaining 4, the ring was visible only after the application of the Bolster technique. The Bolster technique is a simple maneuver that can increase detection rates of Schatzki rings during endoscopy. Copyright © 2016 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  11. Quantitative ENT endoscopy: the future in the new millennium

    Science.gov (United States)

    Mueller, Andreas; Schubert, Mario

    1999-06-01

    In Otorhinolaryngology the endoscopic appraisal of luminal dimensions of the nose, the throat, the larynx and the trachea is a daily problem. Those concerned with endoscopy know, that endoscopes distort dimensions of examined anatomical structures. To draw conclusions on luminal dimensions from the endoscopic pictures additional measuring devices are required. We developed a new method of measuring luminal dimensions in rigid or flexible endoscopy. For this a laser beam directed radially marks the anatomical lumen of interest in the videoendoscopic vision. The laser ring becomes deformed according to the form of the cavity explored. By keeping the distance defined between the laser ring and the top of the endoscope, the endoscopic video image can be measured. A piece of software developed by us calculates from the pictures the cross sectional area as well as the extension of benign or malign stenosis of the cavity explored. The result of the endoscopic measuring procedure can be visualized 3D on a PC-monitor. We are going to demonstrate the result of our clinical experience in different otorhinolaryngological diseases with the new endoscopic measuring kit in comparison to standard endoscopy. A further perspective is the endoscopic measuring kit in comparison to standard endoscopy. A further perspective is the endoscopic assisted manufacturing (EAM) of anatomical adapted stents, tubes and cannules.

  12. Upper Gastro-intestinal'Fibre-Optic Endoscopy

    African Journals Online (AJOL)

    1974-04-27

    Apr 27, 1974 ... A 3-YEAR STUDY AT GROOTE SCHUUR HOSPITAL. B. H. NOVIS, S. BANK, 1. .... ever, in 142 cases endoscopy provided a more definitive diagnosis or .... the best interests of the particular patient, related to the facilities and ...

  13. Barium enema and endoscopy for the detection of colorectal neoplasia: Sensitivity, specificity, complications and its determinants

    International Nuclear Information System (INIS)

    Zwart, Ingrid M. de; Griffioen, Gerrit; Shaw, M. Pertaap Chandie; Lamers, Cornelis B.H.W.; Roos, Albert de

    2001-01-01

    AIM: To analyse sensitivity, specificity and complication rate of endoscopy, and barium enema for the detection of colorectal neoplasia. MATERIALS AND METHODS: A MEDLINE search was performed (1980-2000) directed at the endoscopic and radiologic literature on barium enema. Articles were selected based on the type of study, availability of sensitivity and specificity values in sizeable patient groups, and reports on complications. Sixty articles were included in the analysis. RESULTS: Endoscopy proved to have superior sensitivity for polyps in patients at high-risk for colorectal neoplasia. The role of endoscopy and radiology in average-risk screening populations is not known. Sensitivity and specificity rates ranged widely, probably due to bias. For the detection of small polyps endoscopy has superior performance, whereas sensitivity is similar for endoscopy and barium enema for the detection of larger (>1 cm) polyps and tumours. Overall, endoscopy is associated with a higher complication rate. CONCLUSION: Endoscopy is the preferred detection method in high-risk patients. The role of endoscopy and radiology in a screening setting requires evaluation. This review provides the test characteristics of endoscopy and radiology which are relevant for a cost-effectiveness analysis. Double-contrast barium enema may play an important role for screening purposes, owing to its good sensitivity for detecting larger (>1 cm) polyps and its lack of major complications. Zwart, I.M. de et al. (2001)

  14. Three-dimensional computed tomography of the reconstructed lower urinary tract: technique and findings

    International Nuclear Information System (INIS)

    Frank, R.; Frede, T.; Eder, R.; Recheis, W.; Knapp, R.; zur Nedden, D.; Stenzl, A.; Bartsch, G.

    1998-01-01

    The aim of this pilot study in 54 patients was to improve the visualization of the anatomy and postoperative changes in the pelvic topography after bilateral ureteroileal urethrostomy, using surface rendering of electron beam CT (EBCT) data for the 3D display. Fifty-four patients (39 men and 15 women) were scanned with an EBCT unit between 3 and 110 months after performing orthotopic ureteroileal urethrostomy (''Hemi-Kock'') or ureteroileal rectosigmoidostomy. Various parameters and spatial viewing points were used in the 3D reconstruction, which was performed interactively on external workstations with commercially available software. The anti-reflux nipple was visualized as a distinct structure in all patients. In 8 patients with an interval of more than 12 months between surgery and CT, the pouch had developed an ovoid shape almost indistinguishable from the original bladder. The segmented data sets were partly animated to display the anatomy as virtual endoscopy. Three-dimensional depiction and virtual endoscopy of the neobladder using EBCT are a new way of imaging the postoperative anatomy. Its clinical efficacy in the diagnosis of inconclusive postoperative morbidity, especially voiding problems, and planning of necessary therapy have to be the subject of further evaluation. (orig.)

  15. Binaural Rendering in MPEG Surround

    Directory of Open Access Journals (Sweden)

    Kristofer Kjörling

    2008-04-01

    Full Text Available This paper describes novel methods for evoking a multichannel audio experience over stereo headphones. In contrast to the conventional convolution-based approach where, for example, five input channels are filtered using ten head-related transfer functions, the current approach is based on a parametric representation of the multichannel signal, along with either a parametric representation of the head-related transfer functions or a reduced set of head-related transfer functions. An audio scene with multiple virtual sound sources is represented by a mono or a stereo downmix signal of all sound source signals, accompanied by certain statistical (spatial properties. These statistical properties of the sound sources are either combined with statistical properties of head-related transfer functions to estimate “binaural parameters” that represent the perceptually relevant aspects of the auditory scene or used to create a limited set of combined head-related transfer functions that can be applied directly on the downmix signal. Subsequently, a binaural rendering stage reinstates the statistical properties of the sound sources by applying the estimated binaural parameters or the reduced set of combined head-related transfer functions directly on the downmix. If combined with parametric multichannel audio coders such as MPEG Surround, the proposed methods are advantageous over conventional methods in terms of perceived quality and computational complexity.

  16. Appropriateness of Referrals for Upper Gastrointestinal Endoscopy ...

    African Journals Online (AJOL)

    Appropriateness of Referrals for Upper Gastrointestinal Endoscopy. ... Accra between January and December, 2008 were interviewed and evaluated for this study. ... Presentations with bleeding and suspicion of malignancy showed statistical ...

  17. Temperature feedback in virtual environments

    Science.gov (United States)

    Dionisio, Jose

    1997-02-01

    Virtual reality (VR) is known as one of the most exciting computer-related technologies. Although its definition is still vague among experts, it is expected that a VR system should give the user an experience of being 'immersed' in a synthesized environment. Aims of this deeper level of user immersion range from the look-like of the scenes where realistic rendering is one of the goals (vision stimulus), to interaction paradigms through the use of, e.g., dataglove peripherals type, to acoustics (earring stimulus) trying to merge as much as possible the human senses towards the desired immersion. Attempting to increase the previously mentioned realism, an extra sensorial perception is recalled and the user is exposed to the feeling of 'virtual comfort' by means of a new parameter: the temperature. The obtained results concentrate on interaction paradigms and couple input/output feedback, emphasizing the factor 'presence.' The prototype, although conceptually simple, brings together within a couple of virtual scenarios, a software/hardware solution, so far original in this field.

  18. New light field camera based on physical based rendering tracing

    Science.gov (United States)

    Chung, Ming-Han; Chang, Shan-Ching; Lee, Chih-Kung

    2014-03-01

    Even though light field technology was first invented more than 50 years ago, it did not gain popularity due to the limitation imposed by the computation technology. With the rapid advancement of computer technology over the last decade, the limitation has been uplifted and the light field technology quickly returns to the spotlight of the research stage. In this paper, PBRT (Physical Based Rendering Tracing) was introduced to overcome the limitation of using traditional optical simulation approach to study the light field camera technology. More specifically, traditional optical simulation approach can only present light energy distribution but typically lack the capability to present the pictures in realistic scenes. By using PBRT, which was developed to create virtual scenes, 4D light field information was obtained to conduct initial data analysis and calculation. This PBRT approach was also used to explore the light field data calculation potential in creating realistic photos. Furthermore, we integrated the optical experimental measurement results with PBRT in order to place the real measurement results into the virtually created scenes. In other words, our approach provided us with a way to establish a link of virtual scene with the real measurement results. Several images developed based on the above-mentioned approaches were analyzed and discussed to verify the pros and cons of the newly developed PBRT based light field camera technology. It will be shown that this newly developed light field camera approach can circumvent the loss of spatial resolution associated with adopting a micro-lens array in front of the image sensors. Detailed operational constraint, performance metrics, computation resources needed, etc. associated with this newly developed light field camera technique were presented in detail.

  19. Hindfoot endoscopy for posterior ankle pain

    NARCIS (Netherlands)

    van Dijk, C. Niek

    2006-01-01

    Hindfoot pain can be caused by a variety of pathologies, most of which can be diagnosed and treated with endoscopy. The main indications are posterior tibial tenosynovectomy, diagnosis of a longitudinal peroneus brevis rupture, peroneal tendon adhesiolysis, flexor hallucis longus release, os

  20. Diagnostic Performance of Magnifying Endoscopy for Helicobacter pylori Infection: A Meta-Analysis.

    Directory of Open Access Journals (Sweden)

    Qingqing Qi

    Full Text Available Diagnosis of Helicobacter pylori (H. pylori infection using magnifying endoscopy offers advantages over conventional invasive and noninvasive tests.This meta-analysis aimed to assess the diagnostic performance of magnifying endoscopy in the prediction of H. pylori infection.A literature search of the PubMed, Medline, EMBASE, Science Direct and the Cochrane Library databases was performed. A random-effects model was used to calculate the diagnostic efficiency of magnifying endoscopy for H. pylori infection. A summary receiver operator characteristic curve was plotted, and the area under the curve (AUC was calculated.A total of 18 studies involving 1897 patients were included. The pooled sensitivity and specificity of magnifying endoscopy to predict H. pylori infection were 0.89 [95% confidence interval (CI 0.87-0.91] and 0.82 (95%CI 0.79-0.85, respectively, with an AUC of 0.9461. When targeting the gastric antrum, the pooled sensitivity and specificity were 0.82 (95%CI 0.78-0.86 and 0.72 (95%CI 0.66-0.78, respectively. When targeting the gastric corpus, the pooled sensitivity and specificity were 0.92 (95%CI 0.90-0.94 and 0.86 (95%CI 0.82-0.88, respectively. The pooled sensitivity and specificity using magnifying white light endoscopy were 0.90 (95%CI 0.87-0.91 and 0.81 (95%CI 0.77-0.84, respectively. The pooled sensitivity and specificity using magnifying chromoendoscopy were 0.87 (95%CI 0.83-0.91 and 0.85 (95%CI 0.80-0.88, respectively. The "pit plus vascular pattern" classification in the gastric corpus observed by magnifying endoscopy was able to accurately predict the status of H. pylori infection, as indicated by a pooled sensitivity and specificity of 0.96 (95%CI 0.94-0.97 and 0.91 (95%CI 0.87-0.93, respectively, with an AUC of 0.9872.Magnifying endoscopy was able to accurately predict the status of H. pylori infection, either in magnifying white light endoscopy or magnifying chromoendoscopy mode. The "pit plus vascular pattern

  1. UPPER GASTROINTESTINAL ENDOSCOPY FINDINGS IN PATIENTS REFERRED WITH UPPER GASTROINTESTINAL SYMPTOMS IN ELDORET, KENYA: A RETROSPECTIVE REVIEW.

    Science.gov (United States)

    Ayuo, P O; Some, F F; Kiplagat, J

    2014-08-01

    Dyspepsia is one of the major indications for upper gastrointestinal endoscopy. Other indications include dysphagia, odynophagia and gastrointestinal bleeding. Endoscopy is an expensive procedure that is out of reach of many patients in resource constrained region such as western Kenya. We reviewed endoscopy records from both public and private health institutions spanning ten years. To determine the pattern of referral and endoscopy diagnoses in patients referred for upper gastrointestinal endoscopy in Eldoret, Kenya. Retrospective chart review. Moi Teaching and Referral Hospital, private hospitals and private clinics in Eldoret, Kenya. One thousand six hundred and ninety (1690) Patients who underwent upper GI endoscopy from 1993 to 2003 were reviewed after obtaining clearances from the respective institutions. Information on age, sex, symptoms, and endoscopy diagnosis were extracted and subjected to statistical analysis. The most common symptom was dyspepsia in 1059 (62.7%) followed by dysphagia in 224 (13.3%). Others were referred with diagnosis of cancer of the stomach or oesophagus. Common endoscopy diagnoses were cancer of the oesophagus in 199 (11.8%) and duodenal ulcer in 186 (11.0%). The majority of the patients (30.4%) had normal endoscopy findings. Of the 1059 patients with dyspepsia, only 154 (14.5%) had duodenal ulcer and 34 (3.2%) had gastric ulcers, the majority, 37.2% had normal endoscopy findings. Dyspepsia was main reason for referral, but the majority of such patients had normal findings. Cancer of the oesophagus was the main diagnosis in patients with dysphagia. In view of the cost of endoscopy, only those with dyspepsia and alarm symptoms be referred for the procedure.

  2. [Endoscopy-assisted sialolithectomy for the calculus of the Stensen's duct].

    Science.gov (United States)

    Ye, Xin; Xie, Xiaoyan; Liu, Denggao; Zhang, Lei; Zhang, Zuyan; Yu, Guangyan

    2014-11-01

    To investigate the clinical effects of endoscopy-assisted sialolithectomy for the calculus in the Stensen's duct. From August 2005 to July 2013, 67 consecutive patients with calculus (or foreign bodies) in the Stensen's duct underwent explorative and interventional endoscopy in our hospital. The stones (or foreign bodies) were removed by endoscopy-assisted technique. After operation, the patients were followed-up periodically, and treatment effects were analyzed. Among the 67 patients, the stones (or foreign bodies) were completely removed in 58 cases, and almost completely removed in 3 cases, with a success rate of 87% (58/67). Among the 61 stone-removed cases, treatment options included direct removal with aid of basket or forceps (24 cases), basket entrapment and opening-up of the ostium (21 cases), basket entrapment and mucosal incision near the ostium (8 cases), open removal via buccal incision (2 cases) and open removal via pre-auricular flap (6 cases). During the 6-90 months' follow-up of the 61 cases, 48 cases were asymptomatic, 7 had mild symptoms, 3 developed ductal obturation, 1 had numbness in the parotid region, and the remaining 2 were missed. Endoscopy-assisted sialolithectomy is a safe and effective gland-preservation technique for the patients with parotid gland calculus.

  3. [Sedation with intravenous midazolam during upper gastrointestinal endoscopy--changes in hemodynamics, oxygen saturation and memory].

    Science.gov (United States)

    Mizuno, Ju; Matsuki, Michiko; Gouda, Yoshinori; Nishiyama, Tomoki; Hanaoka, Kazuo

    2003-09-01

    Cardiorespiratory adverse effects are often observed in patients undergoing upper gastrointestinal endoscopy with sedation. In this study, we examined hemodynamics, oxygen saturation and memory during upper gastrointestinal endoscopy under sedation with intravenous midazolam. Eight healthy outpatients without any obvious complications received intravenous midazolam 5 mg for sedation for upper gastrointestinal endoscopy. Blood pressure, heart rate and percutaneous arterial oxygen saturation (SpO2) were measured before, during and after endoscopy. After the arousal by intravenous flumazenil, we inquired the patients about the level of memory during the endoscopy. Blood pressure decreased significantly two minutes after midazolam administration, but increased significantly after the insertion of an endoscope which was not different from the control value. Heart rate increased significantly one and three minutes after the insertion of the endoscope. SpO2 decreased significantly after midazolam administration and stayed at around 95%. No patients remembered the procedure. Sedation with intravenous midazolam during upper gastrointestinal endoscopy is useful to control the cardiovascular responses, and to obtain amnesia. However, a decrease in SpO2 should be watched carefully.

  4. "Endoview" project of intrapartum endoscopy.

    Science.gov (United States)

    Petrikovsky, Boris M; Ravens, Steven

    2002-01-01

    The change in obstetrical practices over the last decade in favor of trials of labor in patients with uterine scars has resulted in increased incidences of uterine ruptures. Although neither repeat cesarean delivery nor a trial of labor is risk free, evidence from a large multicenter study shows vaginal birth after the cesarean (VBAC) is associated with shorter hospital stays, fewer postpartum blood transfusions, and a decreased incidence of postpartum maternal fever. The uterine rupture remains the most serious complication associated with VBAC. Factors associated with uterine rupture include excessive exposure to oxytocin, dysfunctional labor, and a history of more than 1 cesarean delivery.2 Because uterine rupture may be a life-threatening event, intrapartum surveillance and the ability to perform an emergency surgery are both necessary when trial of labor is allowed. Until now, no early symptoms pathognomonic to uterine rupture had been described. We share our experiences with the novel approach to the problem - an intrapartum endoscopy. Endoscopic examination was accomplished by using the intraoperational fiberscope (Olympus and Endoview system (Costa Mesa, CA, USA). A gas-sterilized 25-cm long fiberscope is introduced into the amniotic cavity through the cervical canal after rupture of the membranes. The distance between the fiberscope and the object varies from 3 to 50 mm. The fiberscope has a separate channel for the fluid infusion (normal saline) throughout the procedure; the surgeon looks through the eyepiece directly and exhibits control over the flexible scope. The duration of endoscopy is less than 15 minutes. The inserting of the endoscopic device is very similar to that of insertion of an intrauterine pressure catheter. The IRB Committees of both participating institutions approved the study protocol. Twenty-eight patients with an unknown or poorly documented site of the uterine scar were included in the study. An ultrasound examination had been

  5. The Relationship of Endoscopic Proficiency to Educational Expense for Virtual Reality Simulator Training Amongst Surgical Trainees.

    Science.gov (United States)

    Raque, Jessica; Goble, Adam; Jones, Veronica M; Waldman, Lindsey E; Sutton, Erica

    2015-07-01

    With the introduction of Fundamentals of Endoscopic Surgery, training methods in flexible endoscopy are being augmented with simulation-based curricula. The investment for virtual reality simulators warrants further research into its training advantage. Trainees were randomized into bedside or simulator training groups (BED vs SIM). SIM participated in a proficiency-based virtual reality curriculum. Trainees' endoscopic skills were rated using the Global Assessment of Gastrointestinal Endoscopic Skills (GAGES) in the patient care setting. The number of cases to reach 90 per cent of the maximum GAGES score and calculated costs of training were compared. Nineteen residents participated in the study. There was no difference in the average number of cases required to achieve 90 per cent of the maximum GAGES score for esophagogastroduodenoscopy, 13 (SIM) versus11 (BED) (P = 0.63), or colonoscopy 21 (SIM) versus 4 (BED) (P = 0.34). The average per case cost of training for esophagogastroduodenoscopy was $35.98 (SIM) versus $39.71 (BED) (P = 0.50), not including the depreciation costs associated with the simulator ($715.00 per resident over six years). Use of a simulator appeared to increase the cost of training without accelerating the learning curve or decreasing faculty time spent in instruction. The importance of simulation in endoscopy training will be predicated on more cost-effective simulators.

  6. European Society of Gastrointestinal Endoscopy, European Society of Gastroenterology and Endoscopy Nurses and Associates, and the European Society of Anaesthesiology Guideline: Non-anaesthesiologist administration of propofol for GI endoscopy

    DEFF Research Database (Denmark)

    Dumonceau, J.M.; Riphaus, A.; Aparicio, J.R.

    2010-01-01

    Propofol sedation by non-anaesthesiologists is an upcoming sedation regimen in several countries throughout Europe. Numerous studies have shown the efficacy and safety of this sedation regimen in gastrointestinal endoscopy. Nevertheless, this issue remains highly controversial. The aim of this ev...

  7. European Society of Gastrointestinal Endoscopy, European Society of Gastroenterology and Endoscopy Nurses and Associates, and the European Society of Anaesthesiology Guideline: Non-anesthesiologist administration of propofol for GI endoscopy

    DEFF Research Database (Denmark)

    Dumonceau, J.M.; Riphaus, A.; Aparicio, J.R.

    2010-01-01

    Propofol sedation by non-anesthesiologists is an upcoming sedation regimen in several countries throughout Europe. Numerous studies have shown the efficacy and safety of this sedation regimen in gastrointestinal endoscopy. Nevertheless, this issue remains highly controversial. The aim of this evi...

  8. European Society of Gastrointestinal Endoscopy, European Society of Gastroenterology and Endoscopy Nurses and Associates, and the European Society of Anaesthesiology Guideline: Non-anesthesiologist administration of propofol for GI endoscopy

    NARCIS (Netherlands)

    Dumonceau, J. M.; Riphaus, A.; Aparicio, J. R.; Beilenhoff, U.; Knape, J. T. A.; Ortmann, M.; Paspatis, G.; Ponsioen, C. Y.; Racz, I.; Schreiber, F.; Vilmann, P.; Wehrmann, T.; Wientjes, C.; Walder, B.; Aabakken, L.; Axon, A.; Costamagna, G.; Giostra, E.; Hornslet, P.; Ladas, S.; Marek, T.; Dinis-Ribeiro, M.

    2010-01-01

    Propofol sedation by non-anesthesiologists is an upcoming sedation regimen in several countries throughout Europe. Numerous studies have shown the efficacy and safety of this sedation regimen in gastrointestinal endoscopy. Nevertheless, this issue remains highly controversial. The aim of this

  9. Comparison of a novel bedside portable endoscopy device with nasogastric aspiration for identifying upper gastrointestinal bleeding.

    Science.gov (United States)

    Choi, Jong Hwan; Choi, Jae Hyuk; Lee, Yoo Jin; Lee, Hyung Ki; Choi, Wang Yong; Kim, Eun Soo; Park, Kyung Sik; Cho, Kwang Bum; Jang, Byoung Kuk; Chung, Woo Jin; Hwang, Jae Seok

    2014-07-07

    To compare outcomes using the novel portable endoscopy with that of nasogastric (NG) aspiration in patients with gastrointestinal bleeding. Patients who underwent NG aspiration for the evaluation of upper gastrointestinal (UGI) bleeding were eligible for the study. After NG aspiration, we performed the portable endoscopy to identify bleeding evidence in the UGI tract. Then, all patients underwent conventional esophagogastroduodenoscopy as the gold-standard test. The sensitivity, specificity, and accuracy of the portable endoscopy for confirming UGI bleeding were compared with those of NG aspiration. In total, 129 patients who had GI bleeding signs or symptoms were included in the study (age 64.46 ± 13.79, 91 males). The UGI tract (esophagus, stomach, and duodenum) was the most common site of bleeding (81, 62.8%) and the cause of bleeding was not identified in 12 patients (9.3%). Specificity for identifying UGI bleeding was higher with the portable endoscopy than NG aspiration (85.4% vs 68.8%, P = 0.008) while accuracy was comparable. The accuracy of the portable endoscopy was significantly higher than that of NG in the subgroup analysis of patients with esophageal bleeding (88.2% vs 75%, P = 0.004). Food material could be detected more readily by the portable endoscopy than NG tube aspiration (20.9% vs 9.3%, P = 0.014). No serious adverse effect was observed during the portable endoscopy. The portable endoscopy was not superior to NG aspiration for confirming UGI bleeding site. However, this novel portable endoscopy device might provide a benefit over NG aspiration in patients with esophageal bleeding.

  10. Summary of Guidelines for Infection Prevention and Control for Flexible Gastrointestinal Endoscopy

    Directory of Open Access Journals (Sweden)

    Lawrence Hookey

    2013-01-01

    Full Text Available BACKGROUND: High-quality processes to ensure infection prevention and control in the delivery of safe endoscopy services are essential. In 2010, the Public Health Agency of Canada and the Canadian Association of Gastroenterology (CAG developed a Canadian guideline for the reprocessing of flexible gastrointestinal endoscopy equipment.

  11. RenderGAN: Generating Realistic Labeled Data

    Directory of Open Access Journals (Sweden)

    Leon Sixt

    2018-06-01

    Full Text Available Deep Convolutional Neuronal Networks (DCNNs are showing remarkable performance on many computer vision tasks. Due to their large parameter space, they require many labeled samples when trained in a supervised setting. The costs of annotating data manually can render the use of DCNNs infeasible. We present a novel framework called RenderGAN that can generate large amounts of realistic, labeled images by combining a 3D model and the Generative Adversarial Network framework. In our approach, image augmentations (e.g., lighting, background, and detail are learned from unlabeled data such that the generated images are strikingly realistic while preserving the labels known from the 3D model. We apply the RenderGAN framework to generate images of barcode-like markers that are attached to honeybees. Training a DCNN on data generated by the RenderGAN yields considerably better performance than training it on various baselines.

  12. Physically based rendering from theory to implementation

    CERN Document Server

    Pharr, Matt

    2010-01-01

    "Physically Based Rendering, 2nd Edition" describes both the mathematical theory behind a modern photorealistic rendering system as well as its practical implementation. A method - known as 'literate programming'- combines human-readable documentation and source code into a single reference that is specifically designed to aid comprehension. The result is a stunning achievement in graphics education. Through the ideas and software in this book, you will learn to design and employ a full-featured rendering system for creating stunning imagery. This book features new sections on subsurface scattering, Metropolis light transport, precomputed light transport, multispectral rendering, and much more. It includes a companion site complete with source code for the rendering system described in the book, with support for Windows, OS X, and Linux. Code and text are tightly woven together through a unique indexing feature that lists each function, variable, and method on the page that they are first described.

  13. Stochastic Capsule Endoscopy Image Enhancement

    Directory of Open Access Journals (Sweden)

    Ahmed Mohammed

    2018-06-01

    Full Text Available Capsule endoscopy, which uses a wireless camera to take images of the digestive tract, is emerging as an alternative to traditional colonoscopy. The diagnostic values of these images depend on the quality of revealed underlying tissue surfaces. In this paper, we consider the problem of enhancing the visibility of detail and shadowed tissue surfaces for capsule endoscopy images. Using concentric circles at each pixel for random walks combined with stochastic sampling, the proposed method enhances the details of vessel and tissue surfaces. The framework decomposes the image into two detailed layers that contain shadowed tissue surfaces and detail features. The target pixel value is recalculated for the smooth layer using similarity of the target pixel to neighboring pixels by weighting against the total gradient variation and intensity differences. In order to evaluate the diagnostic image quality of the proposed method, we used clinical subjective evaluation with a rank order on selected KID image database and compared it to state-of-the-art enhancement methods. The result showed that the proposed method provides a better result in terms of diagnostic image quality and objective quality contrast metrics and structural similarity index.

  14. A STUDY OF CORRELATION BETWEEN NASAL ENDOSCOPY AND CT SCAN IN CASES OF CHRONIC RHINOSINUSITIS

    Directory of Open Access Journals (Sweden)

    Arun Kumar

    2015-07-01

    Full Text Available BACKGROUND: The accurate diagnosis of Chronic Rhinosinusitis (CRS is still a challenge therefore, the American Academy of Otorhinolaryngology - Head and Neck Surgery (AAO - HNS 1 has met in a multidisciplinary encounter and formulated a consensus based on only clinical symptoms. The computed tomography (CT scan and the nasal endoscopy (NE were introduced to make an accurate diagnosis of CRS and verify the disease severity. AIM: The aim of this study is to make a correlation between nasal endoscopy and CT scan in cases of clinically diagnosed Chronic Rhinosinusitis patients. METHOD: A study was carried out on 90 patients at Jhalawar Medical College, Jhalawar (Raj. during Sept. 20 12 to Dec. 2014. Diagnostic Nasal Endoscopy and CT Scan PNS done in patients, suffering from Chronic Rhinosinusitis. As a classification instruments, Metson / Gliklich's classification was used to evaluate the tomographic diagnosis and the Stankiewicz / Chow' s classification to evaluate the endoscopic diagnosis of Chronic Rhinosinusitis. RESULTS: Our study showed high specificity of endoscopy in comparison to CT scan though CT scan results are more sensitive. CONCLUSION: Endoscopy can confirm a Chronic Rhinosi nusitis diagnosis, but cannot rule it out, and that CT should be performed in cases of suspected CRS even if mucopurulence is not noted on endoscopy. The CT scan and the nasal endoscopy making easier the treatment planning and the disease resolution.

  15. [Virtual bronchoscopy: the correlation between endoscopic simulation and bronchoscopic findings].

    Science.gov (United States)

    Salvolini, L; Gasparini, S; Baldelli, S; Bichi Secchi, E; Amici, F

    1997-11-01

    We carried out a preliminary clinical validation of 3D spiral CT virtual endoscopic reconstructions of the tracheobronchial tree, by comparing virtual bronchoscopic images with actual endoscopic findings. Twenty-two patients with tracheobronchial disease suspected at preliminary clinical, cytopathological and plain chest film findings were submitted to spiral CT of the chest and bronchoscopy. CT was repeated after endobronchial therapy in 2 cases. Virtual endoscopic shaded-surface-display views of the tracheobronchial tree were reconstructed from reformatted CT data with an Advantage Navigator software. Virtual bronchoscopic images were preliminarily evaluated with a semi-quantitative quality score (excellent/good/fair/poor). The depiction of consecutive airway branches was then considered. Virtual bronchoscopies were finally submitted to double-blind comparison with actual endoscopies. Virtual image quality was considered excellent in 8 cases, good in 14 and fair in 2. Virtual exploration was stopped at the lobar bronchi in one case only; the origin of segmental bronchi was depicted in 23 cases and that of some subsegmental branches in 2 cases. Agreement between actual and virtual bronchoscopic findings was good in all cases but 3 where it was nevertheless considered satisfactory. The yield of clinically useful information differed in 8/24 cases: virtual reconstructions provided more information than bronchoscopy in 5 cases and vice versa in 3. Virtual reconstructions are limited in that the procedure is long and difficult and needing a strictly standardized threshold value not to alter virtual findings. Moreover, the reconstructed surface lacks transparency, there is the partial volume effect and the branches < or = 4 pixels phi and/or meandering ones are difficult to explore. Our preliminary data are encouraging. Segmental bronchi were depicted in nearly all cases, except for the branches involved by disease. Obstructing lesions could be bypassed in some cases

  16. Virtual Reality and its Implementation in Transport Ergonomics

    Directory of Open Access Journals (Sweden)

    Jasna Jurum-Kipke

    2007-03-01

    Full Text Available The experience of our environment is based on the informationthat reach us by means of our sensory organs, andwhich are subsequently processed in our brains. Digital interpretationimplemented to mathematical models of the studiedsubjects brings us to the so-called virtual reality that allows us toreplace some natural human senses, in this case the visualones, by computer-generated infonnation. The procedure is expandedto three-dimensional (3D scanning i. e. searching ofthe special form of the obse1ved subject/object, then digital recordingof the space point cloud (pixels which correspond tothe item, then vectorisation of the fonn, rendering and finallyanimation. In this way, by watching the display, the impressionof the virtual environment can be generated in the human perception.Moreover, in this way the human model can be realizedin a characteristic way in such a virtual space. The implementationof this virtual reality, in accordance with the possibilitiesthat it provides, has been the subject of very intensive researchin the world, and in Croatia as well. The work presentssome possibilities of applying virtual reality in the field of ergonomicanalysis of the collision process of two vehicles.

  17. Advanced Material Rendering in Blender

    Czech Academy of Sciences Publication Activity Database

    Hatka, Martin; Haindl, Michal

    2012-01-01

    Roč. 11, č. 2 (2012), s. 15-23 ISSN 1081-1451 R&D Projects: GA ČR GAP103/11/0335; GA ČR GA102/08/0593 Grant - others:CESNET(CZ) 387/2010; CESNET(CZ) 409/2011 Institutional support: RVO:67985556 Keywords : realistic material rendering * bidirectional texture function * Blender Subject RIV: BD - Theory of Information http://library.utia.cas.cz/separaty/2013/RO/haindl-advanced material rendering in blender.pdf

  18. Upper gastrointestinal endoscopy for dyspepsia: Εxploratory study of factors influencing patient compliance in Greece

    Directory of Open Access Journals (Sweden)

    Kouroumalis Elias

    2011-02-01

    Full Text Available Abstract Background Upper gastrointestinal endoscopy is the most preferable diagnostic examination for patients over fifty when upper gastrointestinal symptoms appear. However, limited knowledge exists in concerns to the compliance of primary care patients' to the doctors' recommendations for endoscopy. Methods Patients who visited primary care practices in Greece and experienced upper gastrointestinal symptoms within a 10 days screening study, were referred for an upper endoscopy exam. The patients which refused to complete the endoscopy exam, were interviewed by the use of an open- ended translated and validated questionnaire, the Identification of Dyspepsia in General Population (IDGP questionnaire. A qualitative thematic analysis grounded on the theory of planned behavior was performed to reveal the reasons for patients' refusal, while socio-demographic predictors were also assessed. Results Nine hundred and ninety two patients were recorded, 159 of them (16% were found positive for dyspepsia and gastro-esophageal reflux disease according to the IDGP questionnaire. Out of the above, 131 (83.6% patients refused further investigation with endoscopy. Patients who refused upper endoscopy were predominantly female (87.8% (p = 0.036 and over the age of 50. The lack of severe symptoms, fear of pain, concerns of sedation, comorbidity and competing life demands were reported by patients as barriers to performing an endoscopic investigation. Conclusions Patients with dyspepsia in rural Greece tend to avoid upper gastrointestinal endoscopy, with two major axons considered to be the causes of patients' refusal: their beliefs towards endoscopy and their personal capability to cope with it. Future research examining reasons of low compliance should be carried out in combination with modern behavioral theories so as to investigate into the above.

  19. A Patient Flow Analysis: Identification of Process Inefficiencies and Workflow Metrics at an Ambulatory Endoscopy Unit

    Directory of Open Access Journals (Sweden)

    Rowena Almeida

    2016-01-01

    Full Text Available Background. The increasing demand for endoscopic procedures coincides with the paradigm shift in health care delivery that emphasizes efficient use of existing resources. However, there is limited literature on the range of endoscopy unit efficiencies. Methods. A time and motion analysis of patient flow through the Hotel-Dieu Hospital (Kingston, Ontario endoscopy unit was followed by qualitative interviews. Procedures were directly observed in three segments: individual endoscopy room use, preprocedure/recovery room, and overall endoscopy unit utilization. Results. Data were collected for 137 procedures in the endoscopy room, 139 procedures in the preprocedure room, and 143 procedures for overall room utilization. The mean duration spent in the endoscopy room was 31.47 min for an esophagogastroduodenoscopy, 52.93 min for a colonoscopy, 30.47 min for a flexible sigmoidoscopy, and 66.88 min for a double procedure. The procedure itself accounted for 8.11 min, 34.24 min, 9.02 min, and 39.13 min for the above procedures, respectively. The focused interviews identified the scheduling template as a major area of operational inefficiency. Conclusions. Despite reasonable procedure times for all except colonoscopies, the endoscopy room durations exceed the allocated times, reflecting the impact of non-procedure-related factors and the need for a revised scheduling template. Endoscopy units have unique operational characteristics and identification of process inefficiencies can lead to targeted quality improvement initiatives.

  20. A Patient Flow Analysis: Identification of Process Inefficiencies and Workflow Metrics at an Ambulatory Endoscopy Unit.

    Science.gov (United States)

    Almeida, Rowena; Paterson, William G; Craig, Nancy; Hookey, Lawrence

    2016-01-01

    Background. The increasing demand for endoscopic procedures coincides with the paradigm shift in health care delivery that emphasizes efficient use of existing resources. However, there is limited literature on the range of endoscopy unit efficiencies. Methods. A time and motion analysis of patient flow through the Hotel-Dieu Hospital (Kingston, Ontario) endoscopy unit was followed by qualitative interviews. Procedures were directly observed in three segments: individual endoscopy room use, preprocedure/recovery room, and overall endoscopy unit utilization. Results. Data were collected for 137 procedures in the endoscopy room, 139 procedures in the preprocedure room, and 143 procedures for overall room utilization. The mean duration spent in the endoscopy room was 31.47 min for an esophagogastroduodenoscopy, 52.93 min for a colonoscopy, 30.47 min for a flexible sigmoidoscopy, and 66.88 min for a double procedure. The procedure itself accounted for 8.11 min, 34.24 min, 9.02 min, and 39.13 min for the above procedures, respectively. The focused interviews identified the scheduling template as a major area of operational inefficiency. Conclusions. Despite reasonable procedure times for all except colonoscopies, the endoscopy room durations exceed the allocated times, reflecting the impact of non-procedure-related factors and the need for a revised scheduling template. Endoscopy units have unique operational characteristics and identification of process inefficiencies can lead to targeted quality improvement initiatives.

  1. PERFORATION AS A COMPLICATION OF THE DIAGNOSTIC UPPER AND LOWER ENDOSCOPY OF THE GASTROINTESTINAL TRACT

    Directory of Open Access Journals (Sweden)

    Ivailo P. Vazharov

    2012-08-01

    Full Text Available Purpose: The purpose of this examination is to evaluate the risk of perforation during endoscopy of upper and lower gastrointestinal tract.Patients and methods used: 1210 diagnostic gastroduodenoscopies and 412 colonoscopies of hospitalized patients were performed by two experienced endoscopists for the period March 2007 – March 2012 at MHAT Varna, MMA. The endoscopies were performed without premedication and sedation. The patients were examined for complications of the procedure during and after the endoscopy. One of the most serious complications is the perforation of the oesophagus, stomach or the large intestine.Results: We had no perforations caused by the examination during the 1210 upper endoscopies performed. We had 2 perforations (0,48% from the 412 colonoscopies performed, which were treated successfully surgically.Conclusions: The perforation is a rare but serious complication of the endoscopy of gastrointestinal tract, which can be healed completely.

  2. RenderSelect: a Cloud Broker Framework for Cloud Renderfarm Services

    OpenAIRE

    Ruby, Annette J; Aisha, Banu W; Subash, Chandran P

    2016-01-01

    In the 3D studios the animation scene files undergo a process called as rendering, where the 3D wire frame models are converted into 3D photorealistic images. As the rendering process is both a computationally intensive and a time consuming task, the cloud services based rendering in cloud render farms is gaining popularity among the animators. Though cloud render farms offer many benefits, the animators hesitate to move from their traditional offline rendering to cloud services based render ...

  3. Individual polyp detection rate in routine daily endoscopy practice depends on case-mix.

    Science.gov (United States)

    Loffeld, R J L F; Liberov, B; Dekkers, P E P

    2015-07-01

    The adenoma detection rate (ADR), a marker of endoscopic quality, is confounded by selection bias. It is not known what the ADR is in normal daily practice. To study the polyp detection rate (PDR) in different endoscopists in the course of years. All consecutive endoscopies of the colon done in 11 years were included. Endoscopies in the regular surveillance programme after polyp removal and after surgery because of colorectal cancer or diverticular disease were scored separately. The number of yearly procedures per endoscopist and presence of polyps, anastomoses, surveillance and cancer were noted. In the period of 11 years, 14,908 consecutive endoscopies of colon and rectum were done by four endoscopists. Two endoscopists had a significantly lower PDR than the other two (p case-mix of patients presented for endoscopy. This result debates the use of the ADR as quality indicator for individual endoscopists.

  4. The endoscopy Global Rating Scale-Canada: development and implementation of a quality improvement tool.

    Science.gov (United States)

    MacIntosh, Donald; Dubé, Catherine; Hollingworth, Roger; Veldhuyzen van Zanten, Sander; Daniels, Sandra; Ghattas, George

    2013-02-01

    Increasing use of gastrointestinal endoscopy, particularly for colorectal cancer screening, and increasing emphasis on health care quality highlight the need for endoscopy facilities to review the quality of the service they offer. To adapt the United Kingdom Global Rating Scale (UK-GRS) to develop a web-based and patient-centred tool to assess and improve the quality of endoscopy services provided. Based on feedback from 22 sites across Canada that completed the UK endoscopy GRS, and integrating results of the Canadian consensus on safety and quality indicators in endoscopy and other Canadian consensus reports, a working group of endoscopists experienced with the GRS developed the GRS-Canada (GRS-C). The GRS-C mirrors the two dimensions (clinical quality and quality of the patient experience) and 12 patient-centred items of the UK-GRS, but was modified to apply to Canadian health care infrastructure, language and current practice. Each item is assessed by a yes⁄no response to eight to 12 statements that are divided into levels graded D (basic) through A (advanced). A core team consisting of a booking clerk, charge nurse and the physician responsible for the unit is recommended to complete the GRS-C twice yearly. The GRS-C is intended to improve endoscopic services in Canada by providing endoscopy units with a straightforward process to review the quality of the service they provide.

  5. A retrospective study of pediatric endoscopy as performed in an adult endoscopy unit Estudio retrospectivo sobre la endoscopia pediátrica desarrollada en un servicio de endoscopias de adultos

    Directory of Open Access Journals (Sweden)

    L. Julián-Gómez

    2010-02-01

    Full Text Available Gastrointestinal endoscopy is a safe, efficient technique with minimal complications, and a useful diagnostic tool for the pediatric population. Under ideal conditions endoscopies for children should be performed by experienced pediatric endoscopists. In this study we report our experience with pediatric endoscopy at the general adult endoscopy unit in our hospital. Our goal is to quantify the number of endoscopies performed in children, as well as their indications and findings, the type of sedation or anesthesia used, and the time waiting for the test to occur. Our experience demonstrates that endoscopists in a general adult gastroenterology department, working together with pediatricians, may perform a relevant number of endoscopies in children in a fast, safe, effective manner.La endoscopia gastrointestinal es una técnica segura y eficiente con mínimas complicaciones, así como una útil herramienta diagnóstica en la población pediátrica. En condiciones ideales, las endoscopias en niños deberían ser realizadas por endoscopistas pediátricos experimentados. En este estudio reportamos nuestra experiencia en la realización de endoscopias pediátricas en la Unidad de Endoscopias general de adultos de nuestro hospital. El objetivo es cuantificar la cantidad de endoscopias realizadas en niños, así como las indicaciones y hallazgos de las mismas, el tipo de sedación o anestesia empleado y el tiempo de espera para la realización de la prueba. Nuestra experiencia demuestra que los endoscopistas de un servicio de gastroenterología general de adultos, en colaboración con pediatras, pueden realizar un número importante de endoscopias a niños, de forma rápida, segura y eficaz.

  6. Canadian Association of Gastroenterology Consensus Guidelines on Safety and Quality Indicators in Endoscopy

    Directory of Open Access Journals (Sweden)

    David Armstrong

    2012-01-01

    Full Text Available Several organizations worldwide have developed procedure-based guidelines and/or position statements regarding various aspects of quality and safety indicators, and credentialing for endoscopy. Although important, they do not specifically address patient needs or provide a framework for their adoption in the context of endoscopy services. The consensus guidelines reported in this article, however, aimed to identify processes and indicators relevant to the provision of high-quality endoscopy services that will support ongoing quality improvement across many jurisdictions, specifically in the areas of ethics, facility standards and policies, quality assurance, training and education, reporting standards and patient perceptions.

  7. LivePhantom: Retrieving Virtual World Light Data to Real Environments.

    Directory of Open Access Journals (Sweden)

    Hoshang Kolivand

    Full Text Available To achieve realistic Augmented Reality (AR, shadows play an important role in creating a 3D impression of a scene. Casting virtual shadows on real and virtual objects is one of the topics of research being conducted in this area. In this paper, we propose a new method for creating complex AR indoor scenes using real time depth detection to exert virtual shadows on virtual and real environments. A Kinect camera was used to produce a depth map for the physical scene mixing into a single real-time transparent tacit surface. Once this is created, the camera's position can be tracked from the reconstructed 3D scene. Real objects are represented by virtual object phantoms in the AR scene enabling users holding a webcam and a standard Kinect camera to capture and reconstruct environments simultaneously. The tracking capability of the algorithm is shown and the findings are assessed drawing upon qualitative and quantitative methods making comparisons with previous AR phantom generation applications. The results demonstrate the robustness of the technique for realistic indoor rendering in AR systems.

  8. VIRTUAL REALITY FOR MANAGEMENT OF SITUATIONAL AWARENESS DURING GLOBAL MASS GATHERINGS

    Directory of Open Access Journals (Sweden)

    A. S. Karsakov

    2017-01-01

    Full Text Available This paper presents a training technology for staff of mass events for development of action skills in large gatherings of people, including crowd dynamic management and actions in extreme situations caused by the panic. The technology is based on the multi-agent model of crowd dynamic with dynamically re-computable navigation fields. We implemented the software system that provides a collaborative and distributed process of training activities in the virtual reality environment. The following characteristics of the developed software system available from experimental studies were analyzed: computational intensity of simulations, scalability of rendering system and reactivity of the final system when rendering computationally intensive scenes. The proposed models and infrastructure for training through collaborative immersion in the virtual reality can improve situational awareness of events staff prior to the event. The developed technology is a unique tool for improving the quality and safety of disposable and unique events involving the broad masses of people, including unfunded by retrospective experience mass gatherings. Developed technology was tested within the Kumbh Mela festival in Ujjain, India.

  9. Computer vision and augmented reality in gastrointestinal endoscopy

    Science.gov (United States)

    Mahmud, Nadim; Cohen, Jonah; Tsourides, Kleovoulos; Berzin, Tyler M.

    2015-01-01

    Augmented reality (AR) is an environment-enhancing technology, widely applied in the computer sciences, which has only recently begun to permeate the medical field. Gastrointestinal endoscopy—which relies on the integration of high-definition video data with pathologic correlates—requires endoscopists to assimilate and process a tremendous amount of data in real time. We believe that AR is well positioned to provide computer-guided assistance with a wide variety of endoscopic applications, beginning with polyp detection. In this article, we review the principles of AR, describe its potential integration into an endoscopy set-up, and envisage a series of novel uses. With close collaboration between physicians and computer scientists, AR promises to contribute significant improvements to the field of endoscopy. PMID:26133175

  10. The Utility of Endoscopic Biopsies in Patients with Normal Upper Endoscopy

    Directory of Open Access Journals (Sweden)

    Anouar Teriaky

    2016-01-01

    Full Text Available Background and Aims. Upper endoscopy is a valuable tool in the workup of gastrointestinal (GI complaints. The purpose of this study is to determine cost and yield of taking biopsies in a normal upper GI tract. Methods. This is a retrospective study where all upper GI biopsies were identified between May 2012 and April 2013, at a tertiary care center. Clinical, procedural, and pathology reports were reviewed to identify patient demographics, procedure information, and pathology diagnosis. Results. Biopsies of the upper GI tract were taken in 1297 patients with normal upper endoscopies. In patients with normal upper endoscopy, 22% of esophageal, 44% of gastric, and 12% of duodenal biopsies were abnormal. The most frequent abnormality was reflux esophagitis in 16% of esophageal biopsies, chronic gastritis in 23% of gastric biopsies, and increased intraepithelial lymphocytes in 6% of duodenal biopsies. The additional cost for taking biopsies in a normal upper GI tract for a diagnosis of eosinophilic esophagitis was $2963 Canadian (CAD, H. pylori associated gastritis was $1404 CAD, and celiac disease was $3024 CAD. Conclusions. The yield of biopsy in normal upper endoscopy varied with location, but the additional expense can be costly and should be tailored to appropriate clinical situations.

  11. Earth mortars and earth-lime renders

    Directory of Open Access Journals (Sweden)

    Maria Fernandes

    2008-01-01

    Full Text Available Earth surface coatings play a decorative architectural role, apart from their function as wall protection. In Portuguese vernacular architecture, earth mortars were usually applied on stone masonry, while earth renders and plasters were used on indoors surface coatings. Limestone exists only in certain areas of the country and consequently lime was not easily available everywhere, especially on granite and schist regions where stone masonry was a current building technique. In the central west coast of Portugal, the lime slaking procedure entailed slaking the quicklime mixed with earth (sandy soil, in a pit; the resulting mixture would then be combined in a mortar or plaster. This was also the procedure for manufactured adobes stabilized with lime. Adobe buildings with earth-lime renderings and plasters were also traditional in the same region, using lime putty and lime wash for final coat and decoration. Classic decoration on earth architecture from the 18th-19th century was in many countries a consequence of the François Cointeraux (1740-1830 manuals - Les Cahiers d'Architecture Rurale" (1793 - a French guide for earth architecture and building construction. This manual arrived to Portugal in the beginning of XIX century, but was never translated to Portuguese. References about decoration for earth houses were explained on this manual, as well as procedures about earth-lime renders and ornamentation of earth walls; in fact, these procedures are exactly the same as the ones used in adobe buildings in this Portuguese region. The specific purpose of the present paper is to show some cases of earth mortars, renders and plasters on stone buildings in Portugal and to explain the methods of producing earth-lime renders, and also to show some examples of rendering and coating with earth-lime in Portuguese adobe vernacular architecture.

  12. Unmeasured improvement work: the lack of routinely collected, service-related data in NHS endoscopy units in England involved in "modernisation"

    Directory of Open Access Journals (Sweden)

    Hutchings Hayley A

    2008-01-01

    Full Text Available Abstract Background The availability of routinely collected service-related endoscopy data from NHS endoscopy units has never been quantified. Methods This retrospective observational study asked 19 endoscopy units to submit copies of all in-house, service-related endoscopy data that had been routinely collected by the unit – Referral numbers, Activity, Number of patients waiting and Number of lost slots. Nine of the endoscopy units had previously participated in the Modernising Endoscopy Services (MES project during 2003 to redesign their endoscopy services. These MES sites had access to additional funding and data collection software. The other ten (Control sites had modernised independently. All data was requested in two phases and corresponded to eight specific time points between January 2003 and April 2006. Results Only eight of 19 endoscopy units submitted routinely collected, service-related data. Another site's data was collected specifically for the study. A further two units claimed to routinely collect service-related data but did not submit any to the study. The remaining eight did not collect any service-related endoscopy data routinely and liaised with their Trust for data. Of the eight sites submitting service-related data, only three were MES project sites. Of these three, the data variables collected were limited and none collected the complete set of endoscopy data variables requested. Of the other five sites, two collected all four endoscopy data types. Data for the three MES project sites went back as far as January 2003, whilst the five Control sites were only able to submit data from December 2003 onwards. Conclusion There was a lack of service-related endoscopy data routinely collected by the study sites, especially those who had participated in the MES project. Without this data, NHS endoscopy services cannot have a true understanding of their services, cannot identify problems and cannot measure the impact of any

  13. Comparison of endoscopy and barium swallow with marshmallow in dysphagia.

    Science.gov (United States)

    Somers, S; Stevenson, G W; Thompson, G

    1986-06-01

    Forty-four patients with dysphagia were examined both by endoscopy and by barium swallow with a marshmallow bolus. In these patients 36 stenoses were found: 34 by radiology and 30 by endoscopy. The radiologic criteria for stenosis included arrest of the marshmallow in a manner to support a column of barium and reproduction of the patient's symptoms at the time this occurred. Radiologic false negative findings were partly due to an inability by patients to swallow an adequate marshmallow bolus; endoscopic failures were associated with small endoscopes and mild stenoses.

  14. A virtual reality endoscopic simulator augments general surgery resident cancer education as measured by performance improvement.

    Science.gov (United States)

    White, Ian; Buchberg, Brian; Tsikitis, V Liana; Herzig, Daniel O; Vetto, John T; Lu, Kim C

    2014-06-01

    Colorectal cancer is the second most common cause of death in the USA. The need for screening colonoscopies, and thus adequately trained endoscopists, particularly in rural areas, is on the rise. Recent increases in required endoscopic cases for surgical resident graduation by the Surgery Residency Review Committee (RRC) further emphasize the need for more effective endoscopic training during residency to determine if a virtual reality colonoscopy simulator enhances surgical resident endoscopic education by detecting improvement in colonoscopy skills before and after 6 weeks of formal clinical endoscopic training. We conducted a retrospective review of prospectively collected surgery resident data on an endoscopy simulator. Residents performed four different clinical scenarios on the endoscopic simulator before and after a 6-week endoscopic training course. Data were collected over a 5-year period from 94 different residents performing a total of 795 colonoscopic simulation scenarios. Main outcome measures included time to cecal intubation, "red out" time, and severity of simulated patient discomfort (mild, moderate, severe, extreme) during colonoscopy scenarios. Average time to intubation of the cecum was 6.8 min for those residents who had not undergone endoscopic training versus 4.4 min for those who had undergone endoscopic training (p Virtual reality endoscopic simulation is an effective tool for both augmenting surgical resident endoscopy cancer education and measuring improvement in resident performance after formal clinical endoscopic training.

  15. Ultrathin endoscopy versus high-resolution endoscopy for diagnosing superficial gastric neoplasia.

    Science.gov (United States)

    Toyoizumi, Hirobumi; Kaise, Mitsuru; Arakawa, Hiroshi; Yonezawa, Jin; Yoshida, Yukinaga; Kato, Masayuki; Yoshimura, Noboru; Goda, Ken-ichi; Tajiri, Hisao

    2009-08-01

    Ultrathin endoscopy (UTE) is an acceptable and cost-effective alternative to EGD with the patient under sedation, although the diagnostic accuracy of UTE is not well established. To compare the diagnostic accuracy of UTE and high-resolution endoscopy (HRE) for superficial gastric neoplasia. Prospective comparative study. Academic center. Patients with or without superficial gastric neoplasia underwent peroral UTE and HRE, back-to-back in a random order while under standard sedation. The procedures were performed by 2 endoscopists who were blinded to the clinical information. The rate of missed lesions and misdiagnosis, sensitivity, and specificity for the diagnosis of gastric neoplasia when using pathology as the reference standard. In total, 126 lesions (41 superficial gastric neoplasias, 85 nonneoplastic lesions) were recorded in 57 enrolled patients. For the diagnosis of gastric neoplasia, the sensitivity of UTE (58.5%) was significantly (P = .021) lower than that of HRE (78%), and the specificity of UTE (91.8%) was significantly (P = .014) lower than that of HRE (100%). The rate of missed lesions and misdiagnosis of gastric neoplasias when using UTE (41.5%) was significantly (P > .001) higher than that of HRE (22.0%). The corresponding rate of neoplasias at the proximal portion (fornix and corpus) when using UTE (29%) was significantly (P = .002) higher than that of HRE (7.2%), although the rates of neoplasias at the distal portion (angulus and antrum) were comparable for UTE and HRE. Small sample numbers in an enriched population. The diagnostic accuracy of UTE is significantly lower than that of HRE for superficial gastric neoplasia, and this difference is particularly striking for neoplasias in the proximal stomach. For UTE to be used as an alternative modality, improvements in optical quality and the incorporation of additional procedures, including close-range observations and chromoendoscopy, are required to enhance visualization.

  16. Analysis of Reconfigured Control Loop with a Virtual Actuator

    Directory of Open Access Journals (Sweden)

    Anna Filasova

    2011-01-01

    Full Text Available Control reconfiguration changes the control structure in response to a fault detected in the plant. This becomes necessary, because a major fault like loss of an actuator breaks the corresponding control loop and therefore renders the whole system inoperable.  An important aim of control reconfiguration is to change the control structure as little as possible, since every change bears the potential of practical problems. The proposed solution is to keep the original controller in the loop and to add an extension called virtual actuator that implements the necessary changes of the control structure. The virtual actuator translates between the signals of the nominal controller and the signal of the faulty plants. This paper is concerned with the analysis of reconfigured loop with a virtual actuator for the system with the faulty actuator. The proposed analysis is illustrated on numerical example.

  17. The Results of Upper Gastrointestinal Endoscopy Performed in Bayburt Province

    Directory of Open Access Journals (Sweden)

    Yavuz Ayar

    2013-09-01

    Full Text Available Aim: We analyzed the results of upper gastrointestinal endoscopy performed between November 2011 and January 2013 in the endoscopy unit at Bayburt State Hospital. Methods: Endoscopic analyses were done with a PENTAX EPK 100P equipment. The results were assessed retrospectively. Results: A total of 1008 patients (664 women, 344 men aged between 17 and 88 (mean: 50±18 years have undergone upper gastrointestinal endoscopy. 186 (18.4% patients were diagnosed with pangastritis, 81 - with esophagitis (8%, 68 - with antral gastritis (6.7%, 67 - with duodenal ulcer (6.6%, 57 - with gastric ulcer (5.6%, 35 - with alkaline reflux gastritis (3.6%, 21 - with duodenitis (2.1%, 5 - with gastric cancer (0.5%, 4 - with esophagial cancer (0.4%, 4 - with gastric polyp (0.4% and 3 patients were diagnosed with esophagial ulcer (0.3%. Conclusion: Lesions were most commonly observed in the stomach. Gastritis, esophagitis, duodenal and gastric ulcer were frequently observed in our city. (The Medical Bulletin of Haseki 2013; 51: 116-9

  18. Virtualization of work in global supply chains

    Directory of Open Access Journals (Sweden)

    Sabina Wyrwich-Płotka

    2016-12-01

    Full Text Available Background: The paper is devoted to the notion and benefits of implementing virtual work in global supply chains. Virtual work must be understood as an intentional activity of a human being, aimed at rendering services (tangible and intangible, by means of ITC tools, performed in a distance from the traditional place of work, in a mobile manner. The empirical research were conducted on the basis of 4 case studies of global leaders of supply chains, which in accordance with M. Fisher's classification, represent two types. The case studies confirmed the positive influence of virtual work both in effective and flexible supply chains. Favourable market and technological conditions and increasing awareness of benefits of virtual work will make it more and more widespread in companies comprising global supply chains. The aim of the study is to demonstrate the cause and effect relationships between virtual work and competitiveness of efficient and flexible supply chain. Methods: The paper is based on the available recent scientific-theoretical research and publication.  The authors analyzed 4 enterprises in Poland. The enterprises representing a flexible or an effective supply chain, either using or not a virtual work. The study carried out the authors had the form of individual interviews. The authors used case studies to show that virtual work brings notable benefits in an effective and flexible supply chain.  Results: Based on these case studies, the authors demonstrated reasons to implement virtual work in selected enterprises. The reasons to implement virtual work are determinants of possible achieve economies in effective and flexible supply chain Conclusions: The examined case studies show that virtual work brings different benefits. In the effective supply chain, virtual workers enable to increase effectiveness and financial results for example. In the flexible supply chain the virtual work can be a way to maintain and build long

  19. VirtualizeMe: Real-time avatar creation for Tele-Immersion environments

    KAUST Repository

    Knoblauch, Daniel

    2010-03-01

    VirtualizeMe introduces a new design for a fully immersive Tele-Immersion system for remote collaboration and virtual world interaction. This system introduces a new avatar creation approach full-filling four main attributes: high resolution, scalability, flexibility and affordability. This is achieved by a total separation of reconstruction and rendering and exploiting the capabilities of modern graphic cards. The high resolution is achieved by using as much of the input information as possible through lossless compression of the input data and introducing a focused volumetric visual hull reconstruction. The resulting avatar allows eye-to-eye collaboration for remote users. The interaction with the virtual world is facilitated by the volumetric avatar model and allows a fully immersive system. This paper shows a proof of concept based on publicly available pre-recorded data to allow easier comparison. ©2010 IEEE.

  20. Endoscopy and autopsy follow-up of biodegradable oesophageal anastomoses in dogs.

    Science.gov (United States)

    Kovács, T; Németh, T; Orosz, Z; Köves, I

    2001-01-01

    The biofragmentable Anastomosis Ring (BAR) is a mechanical device composed of absorbable material and creates an inverting, atraumatic compressive anastomosis with no foreign material at the anastomotic site after healing. The aim of the present experimental study was to assess the safety of oesophagoscopy in early days after oesophageal anastomoses performed with the BAR and to follow-up the healing of BAR anastomoses by in vivo endoscopy and autopsy examination. Thirty mongrel dogs divided into subgroups according to the time-points of endoscopy and autopsy (4th, 7th, 14th, 28th day) were used. There was no significant difference in the healing of anastomoses performed under or above the tracheal bifurcation. Pleural adhesions helped to cover and seal small subclinical leaks. The mortality was 13.3% (4 dogs) and the overall leakage rate 14.3%. We looked for bleeding, haematoma, erosion, ulceration and granulation tissue in the anastomosis. Due to the high mechanical strength of these anastomoses, oesophagoscopy was a safe, easy and feasible method for follow-up BAR intrathoracic anastomoses, with no significant difference between the number of lesions found with endoscopy as compared to the autopsy data. The overall sensitivity of oesophagoscopy to discover mucosal lesions was 73.1%. Endoscopy had no complications, therefore it is a useful method of follow-up and may help predict the normal or compromised healing of oesophageal anastomoses.

  1. Disparities in Receipt of FOBT versus Endoscopy among Filipino American Immigrants

    Science.gov (United States)

    Maxwell, Annette E.; Danao, Leda L.; Crespi, Catherine M.; Antonio, Cynthia; Garcia, Gabriel M.; Bastani, Roshan

    2009-01-01

    Background This report examines disparities associated with the type of colorectal screening test, fecal occult blood test (FOBT) versus endoscopy, within a particular racial/ethnic group, Filipino American immigrants. Methods Between July 2005 and October 2006, Filipino Americans age 50-75 from 31 community organizations in Los Angeles completed a 15-minute survey in English (65%) or Filipino (35%). Results Of the 487 respondents included in this analysis, 257 (53%) had never received any type of colorectal cancer (CRC) screening. Among the 230 subjects who had ever received a routine screening test, 78 had FOBT only (16% of the total sample) and 152 had endoscopy with or without FOBT (31% of the total sample). After controlling for access to care and key demographic variables in a multivariate analysis, only two characteristics distinguished between respondents who had FOBT only versus those who had endoscopy: acculturation, assessed by percent lifetime in the U.S. and language of interview, and income. Conclusions Our data suggest a two tier system, FOBT for less acculturated Filipino Americans with lower income versus endoscopy for Filipino immigrants with higher levels of acculturation and income. The disparity persists after adjusting for access to care. Instead of treating minority groups as monolithic, differences within groups need to be examined so that interventions can be appropriately targeted. PMID:18708385

  2. Outcomes of patients hospitalized with peptic ulcer disease diagnosed in acute upper endoscopy.

    Science.gov (United States)

    Malmi, Hanna; Kautiainen, Hannu; Virta, Lauri J; Färkkilä, Martti A

    2017-11-01

    The incidence and complications of peptic ulcer disease (PUD) have declined, but mortality from bleeding ulcers has remained unchanged. The aims of the current study were to evaluate the significance of PUD among patients admitted for acute upper endoscopy and to evaluate the survival of PUD patients. In this prospective, observational cohort study, data on 1580 acute upper endoscopy cases during 2012-2014 were collected. A total of 649 patients were included with written informed consent. Data on patients' characteristics, living habits, comorbidities, drug use, endoscopy and short-term and long-term survival were collected. Of all patients admitted for endoscopy, 147/649 (23%) had PUD with the main symptom of melena. Of these PUD patients, 35% had major stigmata of bleeding (Forrest Ia-IIb) in endoscopy. Patients with major stigmata had significantly more often renal insufficiency, lower level of blood pressure with tachycardia and lower level of haemoglobin, platelets and ratio of thromboplastin time. No differences in drug use, Charlson comorbidity class, BMI, smoking or alcohol use were found. Of the PUD patients, 31% were Helicobacter pylori positive. The 30-day mortality was 0.7% (95% confidence interval: 0.01-4.7), 1-year mortality was 12.9% (8.4-19.5) and the 2-year mortality was 19.4% (13.8-26.8), with no difference according to major or minor stigmata of bleeding. Comorbidity (Charlson>1) was associated with decreased survival (P=0.029) and obesity (BMI≥30) was associated with better survival (P=0.023). PUD is still the most common cause for acute upper endoscopy with very low short-term mortality. Comorbidity, but not the stigmata of bleeding, was associated with decreased long-term survival.

  3. Prevalence of Helicobacter pylori in Northern Jordan: Endoscopy based study

    International Nuclear Information System (INIS)

    Bani-Hani, Kamal E.; Hammouri, Shadi M.

    2001-01-01

    Helicobacter pylori infection is considered the most common infection worldwide and is associated with many other disorders. The aim of this study is to determine the prevalence of this infection among patients undergoing endoscopy in Northern Jordan. Between November 1998 and September 2000, all patients referred from the Gastro-esophageal Clinic to the Endoscopy Unit at Princess Basma Teaching Hospital, Irbid, Northern Jordan were enrolled in this prospective study. For each patient clinical and epidemiological data was collected and endoscopy was performed. At least 3 antral biopsies were obtained from each patient, and these were examined histologically for the presence of gastritis and stained for Helicobacter pylori using modified Giemsa stain. A total of 197 consecutive patients (113 females) with a mean age of 40.2 years (range 15-91 years) were studied. Abdominal pain was the highest presenting symptom. Gastritis 91% and esophagitis 42% were the most frequent endoscopic findings. Gastritis was documented histologically in 183 (93%) of patients. Helicobacter pylori was found in 161 patients (82%), with all of these having histological gastritis. The 11 patients with gastric ulcer, compared to the 51 out of the 59 (86%) patients with duodenal ulcer, showed Helicobacter pylori in their biopsies. The prevalence of Helicobacter pylori infection in patients subjected to an upper gastrointestinal endoscopy in Jordan is high. This study confirms that Helicobacter pylori is significantly associated with gastritis and peptic ulcer. Further studies are needed to determine the types of Helicobacter pylori strains present in Jordan. (author)

  4. Autofluorescence imaging endoscopy can distinguish non-erosive reflux disease from functional heartburn: A pilot study.

    Science.gov (United States)

    Luo, Xi; Guo, Xiao-Xu; Wang, Wei-Feng; Peng, Li-Hua; Yang, Yun-Sheng; Uedo, Noriya

    2016-04-14

    To investigate whether autofluorescence imaging (AFI) endoscopy can distinguish non-erosive reflux disease (NERD) from functional heartburn (FH). In this prospective observational trial, 127 patients presenting with typical reflux symptoms for > 6 mo were screened. All the participants underwent endoscopy, during which white light imaging (WLI) was followed by AFI. Finally 84 patients with normal esophageal appearance on WLI were enrolled. It was defined as being suggestive of NERD if one or more longitudinal purple lines longer than one centimeter were visualized in the distal part of the esophagus during AFI endoscopy. Ambulatory 24-h multichannel intraluminal impedance and pH monitoring was also performed. After standard proton-pump inhibitor (PPI) tests, subjects were divided into an NERD group and an FH group and the diagnostic performance of AFI endoscopy to differentiate NERD from FH was evaluated. Of 84 endoscopy-negative patients, 36 (42.9%) had a normal pH/impedance test. Of these, 26 patients with favorable responses to PPI tests were classified as having NERD. Finally 10 patients were diagnosed with FH and the others with NERD. Altogether, 68 (81.0%) of the 84 patients were positive on AFI endoscopy. In the NERD group, there were 67 (90.5%) patients with abnormal esophageal findings on AFI endoscopy while only 1 (10%) patient was positive on AFI endoscopy in the FH group. The sensitivity and specificity of AFI in differentiating NERD from FH were 90.5% (95%CI: 81.5%-96.1%) and 90.0% (95%CI: 55.5%-99.7%), respectively. Meanwhile, the accuracy, positive predictive value and negative predictive value of AFI in differentiating between NERD and FH were 90.5% (95%CI: 84.2%-96.8%), 98.5% (95%CI: 92.1%-99.9%) and 56.3% (95%CI: 30.0%-80.2%), respectively. Autofluorescence imaging may serve as a complementary method in evaluating patients with NERD and FH.

  5. Grids, Clouds, and Virtualization

    Science.gov (United States)

    Cafaro, Massimo; Aloisio, Giovanni

    This chapter introduces and puts in context Grids, Clouds, and Virtualization. Grids promised to deliver computing power on demand. However, despite a decade of active research, no viable commercial grid computing provider has emerged. On the other hand, it is widely believed - especially in the Business World - that HPC will eventually become a commodity. Just as some commercial consumers of electricity have mission requirements that necessitate they generate their own power, some consumers of computational resources will continue to need to provision their own supercomputers. Clouds are a recent business-oriented development with the potential to render this eventually as rare as organizations that generate their own electricity today, even among institutions who currently consider themselves the unassailable elite of the HPC business. Finally, Virtualization is one of the key technologies enabling many different Clouds. We begin with a brief history in order to put them in context, and recall the basic principles and concepts underlying and clearly differentiating them. A thorough overview and survey of existing technologies provides the basis to delve into details as the reader progresses through the book.

  6. [Videocapsule endoscopy as a useful tool to diagnose primary intestinal lymphangiectasia].

    Science.gov (United States)

    Vignes, S; Bellanger, J

    2007-03-01

    Primary intestinal lymphangiectasia (Waldmann's disease) lead to a protein-losing enteropathy due to lymph leak into intestinal tract. A 28-year-old woman presented a bilateral lower limb lymphedema. Laboratory examination showing lymphopenia, hypoalbuminemia, hypogammaglobulinemia suggested the diagnosis of primary intestinal lymphangiectasia. Gastroscopy was normal and second duodenum biopsies were negative. Videocapsule endoscopy gave evidence of intestinal lymphangiectasia of the small bowel. Videocapsule endoscopy may be proposed to confirm intestinal lymphangiectasia and to precise their localization when gastroscopy is not conclusive.

  7. Contraindications for video capsule endoscopy

    OpenAIRE

    Bandorski, Dirk; Kurniawan, Niehls; Baltes, Peter; Hoeltgen, Reinhard; Hecker, Matthias; Stunder, Dominik; Keuchel, Martin

    2016-01-01

    Video capsule endoscopy (VCE) has been applied in the last 15 years in an increasing field of applications. Although many contraindications have been put into perspective, some precautions still have to be considered. Known stenosis of the gastrointestinal tract is a clear contraindication for VCE unless surgery is already scheduled or at least has been considered as an optional treatment modality. In patients with a higher incidence of stenosis, as in an established diagnosis of Crohn?s dise...

  8. Back-to-back colon capsule endoscopy and optical colonoscopy in colorectal cancer screening individuals

    DEFF Research Database (Denmark)

    Kobaek-Larsen, Morten; Kroijer, Rasmus; Dyrvig, Anne-Kirstine

    2018-01-01

    mm polyps in colon capsule endoscopy (97%; 95% CI: 94-100) was superior to colonoscopy (89%; 95% CI: 84-94). A complete capsule endoscopy examination (N=134) could detect patients with intermediate or greater risk (according to the European guidelines) with an accuracy, sensitivity, specificity...... and positivity rate of 79%, 93%, 69% and 58% respectively, using a cut-off of at least one polyp >10 mm or more than two polyps. CONCLUSION: Colon capsule endoscopy is superior to colonoscopy in polyp detection rate and per-patient sensitivity to >9 mm polyps, but only in complete CCE examinations. The rate...

  9. Heterogeneous Deformable Modeling of Bio-Tissues and Haptic Force Rendering for Bio-Object Modeling

    Science.gov (United States)

    Lin, Shiyong; Lee, Yuan-Shin; Narayan, Roger J.

    This paper presents a novel technique for modeling soft biological tissues as well as the development of an innovative interface for bio-manufacturing and medical applications. Heterogeneous deformable models may be used to represent the actual internal structures of deformable biological objects, which possess multiple components and nonuniform material properties. Both heterogeneous deformable object modeling and accurate haptic rendering can greatly enhance the realism and fidelity of virtual reality environments. In this paper, a tri-ray node snapping algorithm is proposed to generate a volumetric heterogeneous deformable model from a set of object interface surfaces between different materials. A constrained local static integration method is presented for simulating deformation and accurate force feedback based on the material properties of a heterogeneous structure. Biological soft tissue modeling is used as an example to demonstrate the proposed techniques. By integrating the heterogeneous deformable model into a virtual environment, users can both observe different materials inside a deformable object as well as interact with it by touching the deformable object using a haptic device. The presented techniques can be used for surgical simulation, bio-product design, bio-manufacturing, and medical applications.

  10. Post-processing of digital images.

    Science.gov (United States)

    Perrone, Luca; Politi, Marco; Foschi, Raffaella; Masini, Valentina; Reale, Francesca; Costantini, Alessandro Maria; Marano, Pasquale

    2003-01-01

    Post-processing of bi- and three-dimensional images plays a major role for clinicians and surgeons in both diagnosis and therapy. The new spiral (single and multislice) CT and MRI machines have allowed better quality of images. With the associated development of hardware and software, post-processing has become indispensable in many radiologic applications in order to address precise clinical questions. In particular, in CT the acquisition technique is fundamental and should be targeted and optimized to obtain good image reconstruction. Multiplanar reconstructions ensure simple, immediate display of sections along different planes. Three-dimensional reconstructions include numerous procedures: multiplanar techniques as maximum intensity projections (MIP); surface rendering techniques as the Shaded Surface Display (SSD); volume techniques as the Volume Rendering Technique; techniques of virtual endoscopy. In surgery computer-aided techniques as the neuronavigator, which with information provided by neuroimaging helps the neurosurgeon in simulating and performing the operation, are extremely interesting.

  11. Rendering the Topological Spines

    Energy Technology Data Exchange (ETDEWEB)

    Nieves-Rivera, D. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2015-05-05

    Many tools to analyze and represent high dimensional data already exits yet most of them are not flexible, informative and intuitive enough to help the scientists make the corresponding analysis and predictions, understand the structure and complexity of scientific data, get a complete picture of it and explore a greater number of hypotheses. With this in mind, N-Dimensional Data Analysis and Visualization (ND²AV) is being developed to serve as an interactive visual analysis platform with the purpose of coupling together a number of these existing tools that range from statistics, machine learning, and data mining, with new techniques, in particular with new visualization approaches. My task is to create the rendering and implementation of a new concept called topological spines in order to extend ND²AV's scope. Other existing visualization tools create a representation preserving either the topological properties or the structural (geometric) ones because it is challenging to preserve them both simultaneously. Overcoming such challenge by creating a balance in between them, the topological spines are introduced as a new approach that aims to preserve them both. Its render using OpenGL and C++ and is currently being tested to further on be implemented on ND²AV. In this paper I will present what are the Topological Spines and how they are rendered.

  12. Hyperspectral Imaging Using Flexible Endoscopy for Laryngeal Cancer Detection

    Directory of Open Access Journals (Sweden)

    Bianca Regeling

    2016-08-01

    Full Text Available Hyperspectral imaging (HSI is increasingly gaining acceptance in the medical field. Up until now, HSI has been used in conjunction with rigid endoscopy to detect cancer in vivo. The logical next step is to pair HSI with flexible endoscopy, since it improves access to hard-to-reach areas. While the flexible endoscope’s fiber optic cables provide the advantage of flexibility, they also introduce an interfering honeycomb-like pattern onto images. Due to the substantial impact this pattern has on locating cancerous tissue, it must be removed before the HS data can be further processed. Thereby, the loss of information is to minimize avoiding the suppression of small-area variations of pixel values. We have developed a system that uses flexible endoscopy to record HS cubes of the larynx and designed a special filtering technique to remove the honeycomb-like pattern with minimal loss of information. We have confirmed its feasibility by comparing it to conventional filtering techniques using an objective metric and by applying unsupervised and supervised classifications to raw and pre-processed HS cubes. Compared to conventional techniques, our method successfully removes the honeycomb-like pattern and considerably improves classification performance, while preserving image details.

  13. Virtual MR arthroscopy of the wrist joint: a new intraarticular perspective

    International Nuclear Information System (INIS)

    Sahin, Guelden; Dogan, Basak Erguvan; Demirtas, Mehmet

    2004-01-01

    The aim of this study is to investigate whether virtual MR arthroscopy could be used to visualize the internal architecture of the radiocarpal compartment of the wrist joint in comparison to surgical arthroscopy. Diluted paramagnetic contrast material was injected into the radiocarpal compartment prior to MR examination in all patients. A fat-suppressed T1-weighted three-dimensional fast spoiled gradient echo sequence was acquired in addition to our standard MR imaging protocol in each patient. Three-dimensional data sets were then transferred to an independent workstation and were postprocessed using navigator software to generate surface rendered virtual MR arthroscopic images. Nineteen patients referred for chronic ulnar-sided wrist pain were evaluated with conventional MR arthrography prospectively. Virtual MR arthroscopic images demonstrating the triangular fibrocartilage complex (TFCC) in an intraarticular perspective were achieved in 12 out of 19 patients. Our preliminary investigation suggests that although it has several limitations, virtual MR arthroscopy shows promise in visualizing the TFCC from an intraarticular perspective. (orig.)

  14. Primary intestinal lymphangiectasia diagnosed by capsule endoscopy and double balloon enteroscopy

    Science.gov (United States)

    Oh, Tak Geun; Chung, Joo Won; Kim, Hee Man; Han, Seok-Joo; Lee, Jin Sung; Park, Jung Yeob; Song, Si Young

    2011-01-01

    Primary intestinal lymphangiectasia (PIL) is a rare disorder characterized by dilated intestinal lymphatics and the development of protein-losing enteropathy. Patients with PIL develop hypoalbuminemia, hypocalcemia, lymphopenia and hypogammaglobulinemia, and present with bilateral lower limb edema, fatigue, abdominal pain and diarrhea. Endoscopy reveals diffusely elongated, circumferential and polypoid mucosae covered with whitish enlarged villi, all of which indicate intestinal lymphangiectasia. Diagnosis is confirmed by characteristic tissue pathology, which includes dilated intestinal lymphatics with diffusely swollen mucosa and enlarged villi. The prevalence of PIL has increased since the introduction of capsule endoscopy. The etiology and prevalence of PIL remain unknown. Some studies have reported that several genes and regulatory molecules for lymphangiogenesis are related to PIL. We report the case of a patient with PIL involving the entire small bowel that was confirmed by capsule endoscopy and double-balloon enteroscopy-guided tissue pathology who carried a deletion on chromosome 4q25. The relationship between this deletion on chromosome 4 and PIL remains to be investigated. PMID:22110841

  15. 3-D Sound for Virtual Reality and Multimedia

    Science.gov (United States)

    Begault, Durand R.; Trejo, Leonard J. (Technical Monitor)

    2000-01-01

    Technology and applications for the rendering of virtual acoustic spaces are reviewed. Chapter 1 deals with acoustics and psychoacoustics. Chapters 2 and 3 cover cues to spatial hearing and review psychoacoustic literature. Chapter 4 covers signal processing and systems overviews of 3-D sound systems. Chapter 5 covers applications to computer workstations, communication systems, aeronautics and space, and sonic arts. Chapter 6 lists resources. This TM is a reprint of the 1994 book from Academic Press.

  16. The Endoscopy Global Rating Scale – Canada: Development And Implementation of a Quality Improvement Tool

    Directory of Open Access Journals (Sweden)

    Donald MacIntosh

    2013-01-01

    Full Text Available BACKGROUND: Increasing use of gastrointestinal endoscopy, particularly for colorectal cancer screening, and increasing emphasis on health care quality highlight the need for endoscopy facilities to review the quality of the service they offer.

  17. Sound For Animation And Virtual Reality

    Science.gov (United States)

    Hahn, James K.; Docter, Pete; Foster, Scott H.; Mangini, Mark; Myers, Tom; Wenzel, Elizabeth M.; Null, Cynthia (Technical Monitor)

    1995-01-01

    Sound is an integral part of the experience in computer animation and virtual reality. In this course, we will present some of the important technical issues in sound modeling, rendering, and synchronization as well as the "art" and business of sound that are being applied in animations, feature films, and virtual reality. The central theme is to bring leading researchers and practitioners from various disciplines to share their experiences in this interdisciplinary field. The course will give the participants an understanding of the problems and techniques involved in producing and synchronizing sounds, sound effects, dialogue, and music. The problem spans a number of domains including computer animation and virtual reality. Since sound has been an integral part of animations and films much longer than for computer-related domains, we have much to learn from traditional animation and film production. By bringing leading researchers and practitioners from a wide variety of disciplines, the course seeks to give the audience a rich mixture of experiences. It is expected that the audience will be able to apply what they have learned from this course in their research or production.

  18. Design and implementation of a 3D ocean virtual reality and visualization engine

    Science.gov (United States)

    Chen, Ge; Li, Bo; Tian, Fenglin; Ji, Pengbo; Li, Wenqing

    2012-12-01

    In this study, a 3D virtual reality and visualization engine for rendering the ocean, named VV-Ocean, is designed for marine applications. The design goals of VV-Ocean aim at high fidelity simulation of ocean environment, visualization of massive and multidimensional marine data, and imitation of marine lives. VV-Ocean is composed of five modules, i.e. memory management module, resources management module, scene management module, rendering process management module and interaction management module. There are three core functions in VV-Ocean: reconstructing vivid virtual ocean scenes, visualizing real data dynamically in real time, imitating and simulating marine lives intuitively. Based on VV-Ocean, we establish a sea-land integration platform which can reproduce drifting and diffusion processes of oil spilling from sea bottom to surface. Environment factors such as ocean current and wind field have been considered in this simulation. On this platform oil spilling process can be abstracted as movements of abundant oil particles. The result shows that oil particles blend with water well and the platform meets the requirement for real-time and interactive rendering. VV-Ocean can be widely used in ocean applications such as demonstrating marine operations, facilitating maritime communications, developing ocean games, reducing marine hazards, forecasting the weather over oceans, serving marine tourism, and so on. Finally, further technological improvements of VV-Ocean are discussed.

  19. Detection of ossicular chain abnormalities using CT imaging. Comparison of axial and virtual middle ear endoscopic imaging

    International Nuclear Information System (INIS)

    Sakata, Motomichi; Kamagata, Masaki; Harada, Kuniaki; Shirase, Ryuji; Oomoto, Hidechika; Himi, Tetsuo

    2000-01-01

    The purpose of this study was to evaluate the usefulness of axial and three-dimensional imaging (virtual endoscopy) with helical CT for the detection of ossicular chain abnormalities. In 15 patients who had traumatic ossicular dislocation, disruption, and congenital ossicular defect and anomaly, axial helical CT scanning of the temporal bone was performed with GE HSA. Axial and three-dimensional imaging was carried out in normal ears (15 ears) and abnormal ears (10 ears), for the detection of ossicular chain abnormalities. Diagnostic accuracy was evaluated by receiver-operating-characteristic (ROC) curve analysis using a continuous reporting scale. Furthermore, ROC testing was done to determine the sensitivity, specificity, and accuracy of the detection of ossicular chain abnormalities. Diagnostic accuracy in the detection of ossicular chain abnormalities with three-dimensional imaging (A z =0.967, SD=0.022) was not significantly better than that of axial imaging (A z =0.930, SD=0.046); however, the interobserver standard deviation was better for three-dimensional imaging. Three-dimensional imaging resulted in an increase in true positive cases and a decrease in false negatives. Three-dimensional imaging also showed higher sensitivity and accuracy. In the evaluation of ossicular chain abnormalities, three-dimensional imaging (virtual endoscopy) is useful and provides additional information. Three-dimensional imaging may have an important role in diagnostic procedures and/or preoperative evaluation in otology. (author)

  20. Using a virtual world for robot planning

    Science.gov (United States)

    Benjamin, D. Paul; Monaco, John V.; Lin, Yixia; Funk, Christopher; Lyons, Damian

    2012-06-01

    We are building a robot cognitive architecture that constructs a real-time virtual copy of itself and its environment, including people, and uses the model to process perceptual information and to plan its movements. This paper describes the structure of this architecture. The software components of this architecture include PhysX for the virtual world, OpenCV and the Point Cloud Library for visual processing, and the Soar cognitive architecture that controls the perceptual processing and task planning. The RS (Robot Schemas) language is implemented in Soar, providing the ability to reason about concurrency and time. This Soar/RS component controls visual processing, deciding which objects and dynamics to render into PhysX, and the degree of detail required for the task. As the robot runs, its virtual model diverges from physical reality, and errors grow. The Match-Mediated Difference component monitors these errors by comparing the visual data with corresponding data from virtual cameras, and notifies Soar/RS of significant differences, e.g. a new object that appears, or an object that changes direction unexpectedly. Soar/RS can then run PhysX much faster than real-time and search among possible future world paths to plan the robot's actions. We report experimental results in indoor environments.

  1. Fully wireless pressure sensor based on endoscopy images

    Science.gov (United States)

    Maeda, Yusaku; Mori, Hirohito; Nakagawa, Tomoaki; Takao, Hidekuni

    2018-04-01

    In this paper, the result of developing a fully wireless pressure sensor based on endoscopy images for an endoscopic surgery is reported for the first time. The sensor device has structural color with a nm-scale narrow gap, and the gap is changed by air pressure. The structural color of the sensor is acquired from camera images. Pressure detection can be realized with existing endoscope configurations only. The inner air pressure of the human body should be measured under flexible-endoscope operation using the sensor. Air pressure monitoring, has two important purposes. The first is to quantitatively measure tumor size under a constant air pressure for treatment selection. The second purpose is to prevent the endangerment of a patient due to over transmission of air. The developed sensor was evaluated, and the detection principle based on only endoscopy images has been successfully demonstrated.

  2. Outcomes of Propofol Sedation During Emergency Endoscopy Performed for Upper Gastrointestinal Bleeding.

    Science.gov (United States)

    Park, Chan Hyuk; Han, Dong Soo; Jeong, Jae Yoon; Eun, Chang Soo; Yoo, Kyo-Sang; Jeon, Yong Cheol; Sohn, Joo Hyun

    2016-03-01

    Although propofol-based sedation can be used during emergency endoscopy for upper gastrointestinal bleeding (UGIB), there is a potential risk of sedation-related adverse events, especially in patients with variceal bleeding. We compared adverse events related to propofol-based sedation during emergency endoscopy between patients with non-variceal and variceal bleeding. Clinical records of patients who underwent emergency endoscopy for UGIB under sedation were reviewed. Adverse events, including shock, hypoxia, and paradoxical reaction, were compared between the non-variceal and variceal bleeding groups. Of 703 endoscopies, 539 and 164 were performed for non-variceal and variceal bleeding, respectively. Shock was more common in patients with variceal bleeding compared to those with non-variceal bleeding (12.2 vs. 3.5%, P bleeding (non-variceal bleeding vs. variceal bleeding: hypoxia, 3.5 vs. 1.8%, P = 0.275; paradoxical reaction interfering with the procedure, 4.1 vs. 5.5%, P = 0.442). Although shock was more common in patients with variceal bleeding compared to those with non-variceal bleeding, most cases could be controlled without procedure interruption. Paradoxical reaction, rather than shock or hypoxia, was the most common cause of procedure interruption in patients with variceal bleeding, but the rate did not differ between patients with non-variceal and variceal bleeding.

  3. Is Endoscopy Really Necessary in My Case? A Four Year Retrospective Study.

    Science.gov (United States)

    Dinesh, H N; Kumar, Cd Jagadish; Sanjay, H M; Sachin, V; Basavaraju

    2015-07-01

    About 40% of the general population report dyspepsia at some time in their life making it a fairly common disease. Uncomplicated dyspepsia refers to patients whose dyspepsia is not accompanied by alarm features or associated with NSAIDS usage. To assess the need for UGI Endoscopy and find out the patterns of different endoscopic presentations in patients presenting with uncomplicated dyspepsia. Our study conducted in KR Hospital, Mysore, Department of General Surgery is a retrospective endoscopic study of 1450 patients with uncomplicated dysepsia. A significant 64% of the patients presenting with uncomplicated dyspepsia were found to have findings on endoscopy. The most common age range for positive endoscopic findings was 40-50 years in our hospital. Malignancy was diagnosed in 2.5% patients. We recommend upper GI endoscopy in patients presenting with uncomplicated dyspepsia for patients above 40 years of age in our hospital.

  4. The endoscopy Global Rating Scale – Canada: Development and implementation of a quality improvement tool

    Science.gov (United States)

    MacIntosh, Donald; Dubé, Catherine; Hollingworth, Roger; van Zanten, Sander Veldhuyzen; Daniels, Sandra; Ghattas, George

    2013-01-01

    BACKGROUND: Increasing use of gastrointestinal endoscopy, particularly for colorectal cancer screening, and increasing emphasis on health care quality highlight the need for endoscopy facilities to review the quality of the service they offer. OBJECTIVE: To adapt the United Kingdom Global Rating Scale (UK-GRS) to develop a web-based and patient-centred tool to assess and improve the quality of endoscopy services provided. METHODS: Based on feedback from 22 sites across Canada that completed the UK endoscopy GRS, and integrating results of the Canadian consensus on safety and quality indicators in endoscopy and other Canadian consensus reports, a working group of endoscopists experienced with the GRS developed the GRS-Canada (GRS-C). RESULTS: The GRS-C mirrors the two dimensions (clinical quality and quality of the patient experience) and 12 patient-centred items of the UK-GRS, but was modified to apply to Canadian health care infrastructure, language and current practice. Each item is assessed by a yes/no response to eight to 12 statements that are divided into levels graded D (basic) through A (advanced). A core team consisting of a booking clerk, charge nurse and the physician responsible for the unit is recommended to complete the GRS-C twice yearly. CONCLUSION: The GRS-C is intended to improve endoscopic services in Canada by providing endoscopy units with a straightforward process to review the quality of the service they provide. PMID:23472242

  5. Relationship between timing of endoscopy and mortality in patients with peptic ulcer bleeding

    DEFF Research Database (Denmark)

    Laursen, Stig B; Leontiadis, Grigorios I; Stanley, Adrian J

    2017-01-01

    BACKGROUND AND AIMS: The optimal timing of endoscopy in patients with peptic ulcer bleeding (PUB) remains unclear. The aim of this study was to examine the association between timing of endoscopy and mortality in PUB. METHODS: In a nationwide cohort study based on a database of consecutive patients...

  6. Wearable Vibrotactile Haptic Device for Stiffness Discrimination during Virtual Interactions

    Directory of Open Access Journals (Sweden)

    Andualem Tadesse Maereg

    2017-09-01

    Full Text Available In this paper, we discuss the development of cost effective, wireless, and wearable vibrotactile haptic device for stiffness perception during an interaction with virtual objects. Our experimental setup consists of haptic device with five vibrotactile actuators, virtual reality environment tailored in Unity 3D integrating the Oculus Rift Head Mounted Display (HMD and the Leap Motion controller. The virtual environment is able to capture touch inputs from users. Interaction forces are then rendered at 500 Hz and fed back to the wearable setup stimulating fingertips with ERM vibrotactile actuators. Amplitude and frequency of vibrations are modulated proportionally to the interaction force to simulate the stiffness of a virtual object. A quantitative and qualitative study is done to compare the discrimination of stiffness on virtual linear spring in three sensory modalities: visual only feedback, tactile only feedback, and their combination. A common psychophysics method called the Two Alternative Forced Choice (2AFC approach is used for quantitative analysis using Just Noticeable Difference (JND and Weber Fractions (WF. According to the psychometric experiment result, average Weber fraction values of 0.39 for visual only feedback was improved to 0.25 by adding the tactile feedback.

  7. Clinical Efficacy of Proton Pump Inhibitor versus Prompt Endoscopy for Management of People with Dyspepsia

    DEFF Research Database (Denmark)

    Kjeldsen, Hans Christian; Lauritzen, Torsten; Christensen, Bo

      Title:   Clinical Efficacy of Proton Pump Inhibitor versus Prompt Endoscopy for Management of People with Dyspepsia: A Randomized Clinical Trial in General Practice.     Purpose: To compare the clinical efficacy of two strategies for management of dyspepsia in general practice in a RCT design.......   Setting: June 2000 to August 2002, 41 GPs, Aarhus County, Denmark   Methods: 368 people with dyspepsia (epigastric pain/discomfort, no alarm symptoms) were randomly assigned to treatment with omeprazol 40 mg/day for two weeks (PPI group, n:185) or endoscopy (endoscopy group, n:183). Due to migration......, dyspeptic contacts to GP or patients' satisfaction. Conclusions: Prompt endoscopy was superior to proton pump inhibitor concerning symptom improvement in management of dyspepsia in general practice when pain/discomfort was the primary symptom. There were no differences between the two strategies in respect...

  8. Nasal Anatomy

    Science.gov (United States)

    ... Caregivers Contact ARS HOME ANATOMY Nasal Anatomy Sinus Anatomy Nasal Physiology Nasal Endoscopy Skull Base Anatomy Virtual Anatomy Disclosure ... Size + - Home > ANATOMY > Nasal Anatomy Nasal Anatomy Sinus Anatomy Nasal Physiology Nasal Endoscopy Skull Base Anatomy Virtual Anatomy Disclosure ...

  9. Sinus Anatomy

    Science.gov (United States)

    ... Caregivers Contact ARS HOME ANATOMY Nasal Anatomy Sinus Anatomy Nasal Physiology Nasal Endoscopy Skull Base Anatomy Virtual Anatomy Disclosure ... Size + - Home > ANATOMY > Sinus Anatomy Nasal Anatomy Sinus Anatomy Nasal Physiology Nasal Endoscopy Skull Base Anatomy Virtual Anatomy Disclosure ...

  10. Force Rendering and its Evaluation of a Friction-Based Walking Sensation Display for a Seated User.

    Science.gov (United States)

    Kato, Ginga; Kuroda, Yoshihiro; Kiyokawa, Kiyoshi; Takemura, Haruo

    2018-04-01

    Most existing locomotion devices that represent the sensation of walking target a user who is actually performing a walking motion. Here, we attempted to represent the walking sensation, especially a kinesthetic sensation and advancing feeling (the sense of moving forward) while the user remains seated. To represent the walking sensation using a relatively simple device, we focused on the force rendering and its evaluation of the longitudinal friction force applied on the sole during walking. Based on the measurement of the friction force applied on the sole during actual walking, we developed a novel friction force display that can present the friction force without the influence of body weight. Using performance evaluation testing, we found that the proposed method can stably and rapidly display friction force. Also, we developed a virtual reality (VR) walk-through system that is able to present the friction force through the proposed device according to the avatar's walking motion in a virtual world. By evaluating the realism, we found that the proposed device can represent a more realistic advancing feeling than vibration feedback.

  11. Real-time virtual EAST physical experiment system

    Energy Technology Data Exchange (ETDEWEB)

    Li, Dan, E-mail: lidan@ipp.ac.cn [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei, Anhui (China); Xiao, B.J., E-mail: bjxiao@ipp.ac.cn [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei, Anhui (China); School of Nuclear Science and Technology, University of Science and Technology of China, Hefei, Anhui (China); Xia, J.Y., E-mail: jyxia@ipp.ac.cn [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei, Anhui (China); Yang, Fei, E-mail: fyang@ipp.ac.cn [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei, Anhui (China); Department of Computer Science, Anhui Medical University, Hefei, Anhui (China)

    2014-05-15

    Graphical abstract: - Highlights: • 3D model of experimental advanced superconducting tokamak is established. • Interaction behavior is created that the users can get information from database. • The system integrates data acquisition, plasma shape visualization and simulation. • Browser-oriented system is web-based and more interactive, immersive and convenient. • The system provides the framework for virtual physical experimental environment. - Abstract: As a large fusion reaction device, experimental advanced superconducting tokamak (EAST)’s internal structure is complicated and not easily accessible. Moreover, various diagnostic systems and complicated configuration bring about the inconveniency to the scientists who are unfamiliar with the system but interested in the data. We propose a virtual system to display the 3D model of EAST facility and enable people to view its inner structure and get access to the information of its components in various view sights. We would also provide most of the diagnostic configuration details together with their signal names and physical properties. Compared to the previous ways of viewing information by reference to collected drawings and videos, virtual EAST system is more interactive and immersive. We constructed the browser-oriented virtual EAST physical experiment system, integrated real-time experiment data acquisition, plasma shape visualization and experiment result simulation in order to reproduce physical experiments in a web browser. This system used B/S (Browser/Server) structure in combination with the technology of virtual reality – VRML (Virtual Reality Modeling Language) and Java 3D. In order to avoid the bandwidth limit across internet, we balanced the rendering speed and the precision of the virtual model components. Any registered user can view the experimental information visually and efficiently by logining the system through a web browser. The establishment of the system provides the

  12. Real-time virtual EAST physical experiment system

    International Nuclear Information System (INIS)

    Li, Dan; Xiao, B.J.; Xia, J.Y.; Yang, Fei

    2014-01-01

    Graphical abstract: - Highlights: • 3D model of experimental advanced superconducting tokamak is established. • Interaction behavior is created that the users can get information from database. • The system integrates data acquisition, plasma shape visualization and simulation. • Browser-oriented system is web-based and more interactive, immersive and convenient. • The system provides the framework for virtual physical experimental environment. - Abstract: As a large fusion reaction device, experimental advanced superconducting tokamak (EAST)’s internal structure is complicated and not easily accessible. Moreover, various diagnostic systems and complicated configuration bring about the inconveniency to the scientists who are unfamiliar with the system but interested in the data. We propose a virtual system to display the 3D model of EAST facility and enable people to view its inner structure and get access to the information of its components in various view sights. We would also provide most of the diagnostic configuration details together with their signal names and physical properties. Compared to the previous ways of viewing information by reference to collected drawings and videos, virtual EAST system is more interactive and immersive. We constructed the browser-oriented virtual EAST physical experiment system, integrated real-time experiment data acquisition, plasma shape visualization and experiment result simulation in order to reproduce physical experiments in a web browser. This system used B/S (Browser/Server) structure in combination with the technology of virtual reality – VRML (Virtual Reality Modeling Language) and Java 3D. In order to avoid the bandwidth limit across internet, we balanced the rendering speed and the precision of the virtual model components. Any registered user can view the experimental information visually and efficiently by logining the system through a web browser. The establishment of the system provides the

  13. Moisture movements in render on brick wall

    DEFF Research Database (Denmark)

    Hansen, Kurt Kielsgaard; Munch, Thomas Astrup; Thorsen, Peter Schjørmann

    2003-01-01

    A three-layer render on brick wall used for building facades is studied in the laboratory. The vertical render surface is held in contact with water for 24 hours simulating driving rain while it is measured with non-destructive X-ray equipment every hour in order to follow the moisture front...

  14. How to avoid simulation sickness in virtual environments during user displacement

    Science.gov (United States)

    Kemeny, A.; Colombet, F.; Denoual, T.

    2015-03-01

    Driving simulation (DS) and Virtual Reality (VR) share the same technologies for visualization and 3D vision and may use the same technics for head movement tracking. They experience also similar difficulties when rendering the displacements of the observer in virtual environments, especially when these displacements are carried out using driver commands, including steering wheels, joysticks and nomad devices. High values for transport delay, the time lag between the action and the corresponding rendering cues and/or visual-vestibular conflict, due to the discrepancies perceived by the human visual and vestibular systems when driving or displacing using a control device, induces the so-called simulation sickness. While the visual transport delay can be efficiently reduced using high frequency frame rate, the visual-vestibular conflict is inherent to VR, when not using motion platforms. In order to study the impact of displacements on simulation sickness, we have tested various driving scenarios in Renault's 5-sided ultra-high resolution CAVE. First results indicate that low speed displacements with longitudinal and lateral accelerations under a given perception thresholds are well accepted by a large number of users and relatively high values are only accepted by experienced users and induce VR induced symptoms and effects (VRISE) for novice users, with a worst case scenario corresponding to rotational displacements. These results will be used for optimization technics at Arts et Métiers ParisTech for motion sickness reduction in virtual environments for industrial, research, educational or gaming applications.

  15. Esophageal stenting for benign and malignant disease : European Society of Gastrointestinal Endoscopy (ESGE) Clinical Guideline

    NARCIS (Netherlands)

    Spaander, Manon C W; Baron, Todd H; Siersema, Peter D; Fuccio, Lorenzo; Schumacher, Brigitte; Escorsell, Àngels; Garcia-Pagán, Juan-Carlos; Dumonceau, Jean-Marc; Conio, Massimo; de Ceglie, Antonella; Skowronek, Janusz; Nordsmark, Marianne; Seufferlein, Thomas; Van Gossum, André; Hassan, Cesare; Repici, Alessandro; Bruno, Marco J

    2016-01-01

    This Guideline is an official statement of the European Society of Gastrointestinal Endoscopy (ESGE), endorsed by the European Society for Radiotherapy and Oncology (ESTRO), the European Society of Digestive Endoscopy (ESDO), and the European Society for Clinical Nutrition and Metabolism (ESPEN).

  16. Sketchy Rendering for Information Visualization.

    Science.gov (United States)

    Wood, J; Isenberg, P; Isenberg, T; Dykes, J; Boukhelifa, N; Slingsby, A

    2012-12-01

    We present and evaluate a framework for constructing sketchy style information visualizations that mimic data graphics drawn by hand. We provide an alternative renderer for the Processing graphics environment that redefines core drawing primitives including line, polygon and ellipse rendering. These primitives allow higher-level graphical features such as bar charts, line charts, treemaps and node-link diagrams to be drawn in a sketchy style with a specified degree of sketchiness. The framework is designed to be easily integrated into existing visualization implementations with minimal programming modification or design effort. We show examples of use for statistical graphics, conveying spatial imprecision and for enhancing aesthetic and narrative qualities of visualization. We evaluate user perception of sketchiness of areal features through a series of stimulus-response tests in order to assess users' ability to place sketchiness on a ratio scale, and to estimate area. Results suggest relative area judgment is compromised by sketchy rendering and that its influence is dependent on the shape being rendered. They show that degree of sketchiness may be judged on an ordinal scale but that its judgement varies strongly between individuals. We evaluate higher-level impacts of sketchiness through user testing of scenarios that encourage user engagement with data visualization and willingness to critique visualization design. Results suggest that where a visualization is clearly sketchy, engagement may be increased and that attitudes to participating in visualization annotation are more positive. The results of our work have implications for effective information visualization design that go beyond the traditional role of sketching as a tool for prototyping or its use for an indication of general uncertainty.

  17. Comparative study of image registration techniques for bladder video-endoscopy

    Science.gov (United States)

    Ben Hamadou, Achraf; Soussen, Charles; Blondel, Walter; Daul, Christian; Wolf, Didier

    2009-07-01

    Bladder cancer is widely spread in the world. Many adequate diagnosis techniques exist. Video-endoscopy remains the standard clinical procedure for visual exploration of the bladder internal surface. However, video-endoscopy presents the limit that the imaged area for each image is about nearly 1 cm2. And, lesions are, typically, spread over several images. The aim of this contribution is to assess the performance of two mosaicing algorithms leading to the construction of panoramic maps (one unique image) of bladder walls. The quantitative comparison study is performed on a set of real endoscopic exam data and on simulated data relative to bladder phantom.

  18. Endoscopy as a diagnostic and therapeutic alternative technique of taeniasis.

    Science.gov (United States)

    Canaval Zuleta, Héctor Julián; Company Campins, María M; Dolz Abadía, Carlos

    2016-06-01

    Despite a low incidence in developed countries, gastrointestinal taeniasis should be suspected in patients with abdominal pain, diarrhea, anemia, and/or malabsorption of unknown origin, even more so if they come from endemic regions or areas with poor hygienic and alimentary habits. Diagnosis is traditionally reached by identifying the parasite in stools, but more recently both serological and immunological approaches are also available. Based on a patient diagnosed by gastroscopy, a literature review was undertaken of patients diagnosed by endoscopy. We discuss endoscopy as diagnostic modality, and the effectiveness and safety that endoscopic treatment may provide in view of the potential risk for neurocysticercosis.

  19. Endoscopy as a diagnostic and therapeutic alternative technique of taeniasis

    Directory of Open Access Journals (Sweden)

    Héctor Julian Canaval-Zuleta

    Full Text Available Despite a low incidence in developed countries, gastrointestinal taeniasis should be suspected in patients with abdominal pain, diarrhea, anemia, and/or malabsorption of unknown origin, even more so if they come from endemic regions or areas with poor hygienic and alimentary habits. Diagnosis is traditionally reached by identifying the parasite in stools, but more recently both serological and immunological approaches are also available. Based on a patient diagnosed by gastroscopy, a literature review was undertaken of patients diagnosed by endoscopy. We discuss endoscopy as diagnostic modality, and the effectiveness and safety that endoscopic treatment may provide in view of the potential risk for neurocysticercosis.

  20. Local and Global Illumination in the Volume Rendering Integral

    Energy Technology Data Exchange (ETDEWEB)

    Max, N; Chen, M

    2005-10-21

    This article is intended as an update of the major survey by Max [1] on optical models for direct volume rendering. It provides a brief overview of the subject scope covered by [1], and brings recent developments, such as new shadow algorithms and refraction rendering, into the perspective. In particular, we examine three fundamentals aspects of direct volume rendering, namely the volume rendering integral, local illumination models and global illumination models, in a wavelength-independent manner. We review the developments on spectral volume rendering, in which visible light are considered as a form of electromagnetic radiation, optical models are implemented in conjunction with representations of spectral power distribution. This survey can provide a basis for, and encourage, new efforts for developing and using complex illumination models to achieve better realism and perception through optical correctness.

  1. Spatial augmented reality merging real and virtual worlds

    CERN Document Server

    Bimber, Oliver

    2005-01-01

    Like virtual reality, augmented reality is becoming an emerging platform in new application areas for museums, edutainment, home entertainment, research, industry, and the art communities using novel approaches which have taken augmented reality beyond traditional eye-worn or hand-held displays. In this book, the authors discuss spatial augmented reality approaches that exploit optical elements, video projectors, holograms, radio frequency tags, and tracking technology, as well as interactive rendering algorithms and calibration techniques in order to embed synthetic supplements into the real

  2. Role of endoscopy in gastroesophageal reflux disease

    Directory of Open Access Journals (Sweden)

    Tarun Rai

    2015-01-01

    Full Text Available Gastroesophageal reflux disease is a condition due to reflux of stomach content in the esophagus causing trouble symptoms or complications or both. GERD is a clinical diagnosis and typically presents with a heartburn and/or regurgitation and a positive response to antacid secretory medications. GERD is the leading outpatient diagnosis among all gastrointestinal disorders in the United States. Approximately 40% of population report occasional symptoms of GERD whereas 10-20% of patients will have symptoms at least once in a week. Recent guidelines from gastrointestinal societies such as American College of Gastroenterology, American Society for Gastrointestinal Endoscopy and American College of Physicians have laid out specific indications regarding role of esophagogastroduodenoscopy in GERD. Despite these recommendations, studies have revealed that one-fifth to two-fifth EGDs may not be clinically indicated, especially where open access endoscopy referral system is used. Traditionally, GERD has been thought to be a disease of the western world. Prevalence rates had been estimated to be lower in Asia when compared to that of the Western Countries. Few recent epidemiological studies in India showed the prevalence of reflux disease in India to be between 8-24%, which is comparable to the western world. The use of EGDs becomes more critical for developing countries such as India where prevalence of GERD and BE is comparable to the western countries but have limited resources. In addition to direct cost for an EGD, it burdens economy with indirect costs such as time off from the work, transportation and any procedural complications. Risk stratifying patients with GERD may therefore prevent unnecessary procedures, harms and costs. The aim of this paper is to review the existing evidence on the role of endoscopy in GERD.

  3. Sedation-related complications in gastrointestinal endoscopy

    OpenAIRE

    Amornyotin, Somchai

    2013-01-01

    Sedation practices for gastrointestinal endoscopic (GIE) procedures vary widely in different countries depending on health system regulations and local circumstances. The goal of procedural sedation is the safe and effective control of pain and anxiety, as well as to provide an appropriate degree of memory loss or decreased awareness. Sedation-related complications in gastrointestinal endoscopy, once occurred, can lead to significant morbidity and occasional mortality in patients. The risk fa...

  4. Cecal perforation with an ascending colon cancer caused by upper gastrointestinal endoscopy

    Directory of Open Access Journals (Sweden)

    Hiroyuki Miyatani

    2009-04-01

    Full Text Available Hiroyuki Miyatani1, Yukio Yoshida1, Hirokazu Kiyozaki21Department of Gastroenterology, Jichi Medical University, Saitama Medical Center, Saitama, Japan; 2Department of Surgery, Jichi Medical University, Saitama Medical Center, Saitama, JapanAbstract: Colonic perforation caused by upper gastrointestinal (GI endoscopy is extremely rare. A 69-year-old woman was referred to our hospital because of abdominal fullness. Colonoscopy could be performed only up to the hepatic flexure due to an elongated colon and residual stools. Because her symptoms improved, upper GI endoscopy was performed 11 days later. The patient developed severe abdominal pain two hours after the examination. Abdominal X-ray and computed tomography showed massive free air. Immediate laparotomy was performed for the intestinal perforation. After removal of stool, a perforation site was detected in the cecum with an invasive ascending colon cancer. Therefore, a right hemicolectomy, ileostomy, and transverse colostomy were performed. Although she developed postoperative septicemia, the patient was discharged 38 days after admission. Seven months postoperatively, the patient died of lung, liver, and brain metastases. Even in cases with a lesion that is not completely obstructed, it is important to note that air insufflations during upper GI endoscopy can perforate the intestinal wall in patients with advanced colon cancer.Keywords: colonic perforation, colon cancer, upper gastrointestinal endoscopy, fecal peritonitis

  5. Standardized rendering from IR surveillance motion imagery

    Science.gov (United States)

    Prokoski, F. J.

    2014-06-01

    Government agencies, including defense and law enforcement, increasingly make use of video from surveillance systems and camera phones owned by non-government entities.Making advanced and standardized motion imaging technology available to private and commercial users at cost-effective prices would benefit all parties. In particular, incorporating thermal infrared into commercial surveillance systems offers substantial benefits beyond night vision capability. Face rendering is a process to facilitate exploitation of thermal infrared surveillance imagery from the general area of a crime scene, to assist investigations with and without cooperating eyewitnesses. Face rendering automatically generates greyscale representations similar to police artist sketches for faces in surveillance imagery collected from proximate locations and times to a crime under investigation. Near-realtime generation of face renderings can provide law enforcement with an investigation tool to assess witness memory and credibility, and integrate reports from multiple eyewitnesses, Renderings can be quickly disseminated through social media to warn of a person who may pose an immediate threat, and to solicit the public's help in identifying possible suspects and witnesses. Renderings are pose-standardized so as to not divulge the presence and location of eyewitnesses and surveillance cameras. Incorporation of thermal infrared imaging into commercial surveillance systems will significantly improve system performance, and reduce manual review times, at an incremental cost that will continue to decrease. Benefits to criminal justice would include improved reliability of eyewitness testimony and improved accuracy of distinguishing among minority groups in eyewitness and surveillance identifications.

  6. Animation company "Fast Forwards" production with HP Utility Data Center; film built using Adaptive Enterprise framework enabled by shared, virtual resource

    CERN Multimedia

    2003-01-01

    Hewlett Packard have produced a commercial-quality animated film using an experimental rendering service from HP Labs and running on an HP Utility Data Center (UDC). The project demonstrates how computing resources can be managed virtually and illustrates the value of utility computing, in which an end-user taps into a large pool of virtual resources, but pays only for what is used (1 page).

  7. A cerebrovascular stroke following endoscopy for an elderly patient ...

    African Journals Online (AJOL)

    Ahmed Gado

    2015-02-02

    Feb 2, 2015 ... gastrointestinal bleeding. Not only in upper gastrointestinal bleeding is advanced age a risk of ... plaining of hematemesis of large amount of coffee ground blood. ..... Green J. Complications of gastrointestinal endoscopy. BSG.

  8. Remote volume rendering pipeline for mHealth applications

    Science.gov (United States)

    Gutenko, Ievgeniia; Petkov, Kaloian; Papadopoulos, Charilaos; Zhao, Xin; Park, Ji Hwan; Kaufman, Arie; Cha, Ronald

    2014-03-01

    We introduce a novel remote volume rendering pipeline for medical visualization targeted for mHealth (mobile health) applications. The necessity of such a pipeline stems from the large size of the medical imaging data produced by current CT and MRI scanners with respect to the complexity of the volumetric rendering algorithms. For example, the resolution of typical CT Angiography (CTA) data easily reaches 512^3 voxels and can exceed 6 gigabytes in size by spanning over the time domain while capturing a beating heart. This explosion in data size makes data transfers to mobile devices challenging, and even when the transfer problem is resolved the rendering performance of the device still remains a bottleneck. To deal with this issue, we propose a thin-client architecture, where the entirety of the data resides on a remote server where the image is rendered and then streamed to the client mobile device. We utilize the display and interaction capabilities of the mobile device, while performing interactive volume rendering on a server capable of handling large datasets. Specifically, upon user interaction the volume is rendered on the server and encoded into an H.264 video stream. H.264 is ubiquitously hardware accelerated, resulting in faster compression and lower power requirements. The choice of low-latency CPU- and GPU-based encoders is particularly important in enabling the interactive nature of our system. We demonstrate a prototype of our framework using various medical datasets on commodity tablet devices.

  9. Organization and logistics of drug-induced sleep endoscopy in a training hospital.

    Science.gov (United States)

    Benoist, L B L; de Vries, N

    2015-09-01

    Drug-induced sleep endoscopy (DISE) is a rapidly growing method to evaluate airway collapse in patients receiving non-CPAP therapies for sleep-disordered breathing (SDB). The growing number of DISEs has consequences for the organization of clinical protocols. In this paper we present our recent experiences with DISE, performed by an ENT resident, with sedation given by a nurse anesthetist, in an outpatient endoscopy setting, while the staff member/sleep surgeon discusses the findings and the recommended treatment proposal on the same day.

  10. Upper and Lower Urinary Tract Endoscopy Training on Thiel-embalmed Cadavers.

    Science.gov (United States)

    Bele, Uros; Kelc, Robi

    2016-07-01

    To evaluate Thiel-embalmed cadavers as a new training model for urological endoscopy procedures. Twelve urologists performed upper and lower urinary tract endoscopies on 5 different Thiel-embalmed cadavers to evaluate this potentially new training model in urological endoscopic procedural training. Using a 5-point Likert scale, the participants assessed the quality of the tissue and the overall experience of the endoscopy in comparison to a live patient procedure. Thiel-embalmed cadavers have shown to mimic live patient endoscopy of the upper and lower urinary tract in terms of almost identical overall anatomical conditions and manipulation characteristics of the tissue. The mucosa of the urethra and ureters showed similar colors and consistency in comparison to a live patient, whereas bladder mucosa was lacking the visibility of the vessels, thus was unsuitable for identifying any mucosal abnormalities. The flexibility of the muscles allowed for proper patient positioning, whereas the loss of muscle tonus made ureteroscopy more difficult although sufficiently comparable to the procedure done in a live patient. Thiel-embalmed cadavers have already been proven to be a suitable training model for several medical procedures. They are known for preserving tissue color, consistency, and flexibility without the irritant odors or risk of infection, which make them resemble live patients with real-life surgical challenges. The results of our study strongly suggest that despite some minor drawbacks, Thiel-embalmed cadavers are a suitable simulation model for initial training of urethrocystoscopy and ureteroscopy. Copyright © 2016 Elsevier Inc. All rights reserved.

  11. A Planetarium Inside Your Office: Virtual Reality in the Dome Production Pipeline

    Science.gov (United States)

    Summers, Frank

    2018-01-01

    Producing astronomy visualization sequences for a planetarium without ready access to a dome is a distorted geometric challenge. Fortunately, one can now use virtual reality (VR) to simulate a dome environment without ever leaving one's office chair. The VR dome experience has proven to be a more than suitable pre-visualization method that requires only modest amounts of processing beyond the standard production pipeline. It also provides a crucial testbed for identifying, testing, and fixing the visual constraints and artifacts that arise in a spherical presentation environment. Topics adreesed here will include rendering, geometric projection, movie encoding, software playback, and hardware setup for a virtual dome using VR headsets.

  12. Missing depth cues in virtual reality limit performance and quality of three dimensional reaching movements.

    Science.gov (United States)

    Gerig, Nicolas; Mayo, Johnathan; Baur, Kilian; Wittmann, Frieder; Riener, Robert; Wolf, Peter

    2018-01-01

    Goal-directed reaching for real-world objects by humans is enabled through visual depth cues. In virtual environments, the number and quality of available visual depth cues is limited, which may affect reaching performance and quality of reaching movements. We assessed three-dimensional reaching movements in five experimental groups each with ten healthy volunteers. Three groups used a two-dimensional computer screen and two groups used a head-mounted display. The first screen group received the typically recreated visual depth cues, such as aerial and linear perspective, occlusion, shadows, and texture gradients. The second screen group received an abstract minimal rendering lacking those. The third screen group received the cues of the first screen group and absolute depth cues enabled by retinal image size of a known object, which realized with visual renderings of the handheld device and a ghost handheld at the target location. The two head-mounted display groups received the same virtually recreated visual depth cues as the second or the third screen group respectively. Additionally, they could rely on stereopsis and motion parallax due to head-movements. All groups using the screen performed significantly worse than both groups using the head-mounted display in terms of completion time normalized by the straight-line distance to the target. Both groups using the head-mounted display achieved the optimal minimum in number of speed peaks and in hand path ratio, indicating that our subjects performed natural movements when using a head-mounted display. Virtually recreated visual depth cues had a minor impact on reaching performance. Only the screen group with rendered handhelds could outperform the other screen groups. Thus, if reaching performance in virtual environments is in the main scope of a study, we suggest applying a head-mounted display. Otherwise, when two-dimensional screens are used, achievable performance is likely limited by the reduced depth

  13. A Sort-Last Rendering System over an Optical Backplane

    Directory of Open Access Journals (Sweden)

    Yasuhiro Kirihata

    2005-06-01

    Full Text Available Sort-Last is a computer graphics technique for rendering extremely large data sets on clusters of computers. Sort-Last works by dividing the data set into even-sized chunks for parallel rendering and then composing the images to form the final result. Since sort-last rendering requires the movement of large amounts of image data among cluster nodes, the network interconnecting the nodes becomes a major bottleneck. In this paper, we describe a sort-last rendering system implemented on a cluster of computers whose nodes are connected by an all-optical switch. The rendering system introduces the notion of the Photonic Computing Engine, a computing system built dynamically by using the optical switch to create dedicated network connections among cluster nodes. The sort-last volume rendering algorithm was implemented on the Photonic Computing Engine, and its performance is evaluated. Prelimi- nary experiments show that performance is affected by the image composition time and average payload size. In an attempt to stabilize the performance of the system, we have designed a flow control mechanism that uses feedback messages to dynamically adjust the data flow rate within the computing engine.

  14. Observation of rat's colon polyps in real time by mini-endoscopy and raman spectroscopy

    Science.gov (United States)

    Andriana, Bibin Bintang; Mahardika, Anggara; Taketani, Akihiro; Sato, Hidetoshi

    2018-02-01

    Colorectal adenoma (CA) is a disease caused by various factors (such as genetic factors or environmental exposures). The appearance of colon polyp (CP) within colorectal might indicate the hint of CA development. Ball-lens hollow fiber Raman probe (BHRP) may has a high capability for detection of CA in living experimental animal and have already tested to rat's CP in this study, which was designed to collaborate between BHRP with mini-endoscopy to observe the biochemical alteration within normal colon tissue and rat's colon polyps in real time. BHRP and mini-endoscopy can distinguish the differences in their finger print spectra and make pictures the control and CP in the real time. At the first step, the real situation of normal colon and Rat's CP were washed by saline and observed with mini-endoscopy. BHRP was introduced to Dextran sodium sulphate (DSS)-induced Rat's CP to detect some of biochemical alteration. The main purpose of this study was to introduce mini-endoscopy to guide the BHRP for diagnosing of CP in real time and to compare it with spectra of normal colon (control group) in living rat. As the result, BHRP can provide the differences in band of control and CP group, which can inform that the biochemical of normal and CP has changed. As a major parameter to distinct normal and CP tissue were phosphatidylinositol, phosphodiester group, lipid, and collagen. Mini endoscopy and BHRP is very sensitive devices for diagnosing of CP in real time.

  15. Virtual haptic system for intuitive planning of bone fixation plate placement

    Directory of Open Access Journals (Sweden)

    Kup-Sze Choi

    2017-01-01

    Full Text Available Placement of pre-contoured fixation plate is a common treatment for bone fracture. Fitting of fixation plates on fractured bone can be preoperatively planned and evaluated in 3D virtual environment using virtual reality technology. However, conventional systems usually employ 2D mouse and virtual trackball as the user interface, which makes the process inconvenient and inefficient. In the paper, a preoperative planning system equipped with 3D haptic user interface is proposed to allow users to manipulate the virtual fixation plate intuitively to determine the optimal position for placement on distal medial tibia. The system provides interactive feedback forces and visual guidance based on the geometric requirements. Creation of 3D models from medical imaging data, collision detection, dynamics simulation and haptic rendering are discussed. The system was evaluated by 22 subjects. Results show that the time to achieve optimal placement using the proposed system was shorter than that by using 2D mouse and virtual trackball, and the satisfaction rating was also higher. The system shows potential to facilitate the process of fitting fixation plates on fractured bones as well as interactive fixation plate design.

  16. GPU Pro 5 advanced rendering techniques

    CERN Document Server

    Engel, Wolfgang

    2014-01-01

    In GPU Pro5: Advanced Rendering Techniques, section editors Wolfgang Engel, Christopher Oat, Carsten Dachsbacher, Michal Valient, Wessam Bahnassi, and Marius Bjorge have once again assembled a high-quality collection of cutting-edge techniques for advanced graphics processing unit (GPU) programming. Divided into six sections, the book covers rendering, lighting, effects in image space, mobile devices, 3D engine design, and compute. It explores rasterization of liquids, ray tracing of art assets that would otherwise be used in a rasterized engine, physically based area lights, volumetric light

  17. Fast algorithm for the rendering of three-dimensional surfaces

    Science.gov (United States)

    Pritt, Mark D.

    1994-02-01

    It is often desirable to draw a detailed and realistic representation of surface data on a computer graphics display. One such representation is a 3D shaded surface. Conventional techniques for rendering shaded surfaces are slow, however, and require substantial computational power. Furthermore, many techniques suffer from aliasing effects, which appear as jagged lines and edges. This paper describes an algorithm for the fast rendering of shaded surfaces without aliasing effects. It is much faster than conventional ray tracing and polygon-based rendering techniques and is suitable for interactive use. On an IBM RISC System/6000TM workstation it renders a 1000 X 1000 surface in about 7 seconds.

  18. Innovative Lime Pozzolana Renders for Reconstruction of Historical Buildings

    International Nuclear Information System (INIS)

    Vejmelkova, E.; Maca, P.; Konvalinka, P.; Cerny, R.

    2011-01-01

    Bulk density, matrix density, open porosity, compressive strength, bending strength, water sorptivity, moisture diffusivity, water vapor diffusion coefficient, thermal conductivity, specific heat capacity and thermal diffusivity of two innovative renovation renders on limepozzolana basis are analyzed. The obtained results are compared with reference lime plaster and two commercial renovation renders, and conclusions on the applicability of the particular renders in practical reconstruction works are drawn. (author)

  19. Endoscopic findings in patients with upper gastrointestinal bleeding clinically classified into three risk groups prior to endoscopy

    OpenAIRE

    Tammaro, Leonardo; Paolo, Maria Carla Di; Zullo, Angelo; Hassan, Cesare; Morini, Sergio; Caliendo, Sebastiano; Pallotta, Lorella

    2008-01-01

    AIM: To investigate in a prospective study whether a simplified clinical score prior to endoscopy in upper gastrointestinal bleeding (UGIB) patients was able to predict endoscopic findings at urgent endoscopy.

  20. Swallowable Wireless Capsule Endoscopy: Progress and Technical Challenges

    Directory of Open Access Journals (Sweden)

    Guobing Pan

    2012-01-01

    Full Text Available Wireless capsule endoscopy (WCE offers a feasible noninvasive way to detect the whole gastrointestinal (GI tract and revolutionizes the diagnosis technology. However, compared with wired endoscopies, the limited working time, the low frame rate, and the low image resolution limit the wider application. The progress of this new technology is reviewed in this paper, and the evolution tendencies are analyzed to be high image resolution, high frame rate, and long working time. Unfortunately, the power supply of capsule endoscope (CE is the bottleneck. Wireless power transmission (WPT is the promising solution to this problem, but is also the technical challenge. Active CE is another tendency and will be the next geneion of the WCE. Nevertheless, it will not come true shortly, unless the practical locomotion mechanism of the active CE in GI tract is achieved. The locomotion mechanism is the other technical challenge, besides the challenge of WPT. The progress about the WPT and the active capsule technology is reviewed.

  1. Technology Insight: current status of video capsule endoscopy.

    Science.gov (United States)

    Cave, David R

    2006-03-01

    Video capsule endoscopy (VCE) is the most recent major practical and conceptual development in the field of endoscopy. The video capsule endoscope-a small, pill-sized, passive imaging device-has been demonstrated to be the pre-eminent imaging device for disorders of the small intestine. The initial use for VCE was to detect the origin of obscure gastrointestinal bleeding. Several other indications have now been justified, or are in the process of evaluation. More than 200,000 of these disposable devices have been used worldwide, with an extraordinarily good safety record: indeed, the device has been approved for use in children as young as 10 years of age. In addition, a double-ended capsule has now been approved for the evaluation of mucosal disease in the esophagus. The now-widespread deployment of the device into gastrointestinal practice in the US and many other countries suggests that VCE has achieved mainstream utility. The development of similar competitor devices, and devices whose movement can be controlled, is in progress.

  2. 3D visualisation of the middle ear and adjacent structures using reconstructed multi-slice CT datasets, correlating 3D images and virtual endoscopy to the 2D cross-sectional images

    International Nuclear Information System (INIS)

    Rodt, T.; Ratiu, P.; Kacher, D.F.; Anderson, M.; Jolesz, F.A.; Kikinis, R.; Becker, H.; Bartling, S.

    2002-01-01

    The 3D imaging of the middle ear facilitates better understanding of the patient's anatomy. Cross-sectional slices, however, often allow a more accurate evaluation of anatomical structures, as some detail may be lost through post-processing. In order to demonstrate the advantages of combining both approaches, we performed computed tomography (CT) imaging in two normal and 15 different pathological cases, and the 3D models were correlated to the cross-sectional CT slices. Reconstructed CT datasets were acquired by multi-slice CT. Post-processing was performed using the in-house software ''3D Slicer'', applying thresholding and manual segmentation. 3D models of the individual anatomical structures were generated and displayed in different colours. The display of relevant anatomical and pathological structures was evaluated in the greyscale 2D slices, 3D images, and the 2D slices showing the segmented 2D anatomy in different colours for each structure. Correlating 2D slices to the 3D models and virtual endoscopy helps to combine the advantages of each method. As generating 3D models can be extremely time-consuming, this approach can be a clinically applicable way of gaining a 3D understanding of the patient's anatomy by using models as a reference. Furthermore, it can help radiologists and otolaryngologists evaluating the 2D slices by adding the correct 3D information that would otherwise have to be mentally integrated. The method can be applied to radiological diagnosis, surgical planning, and especially, to teaching. (orig.)

  3. NEDE: an open-source scripting suite for developing experiments in 3D virtual environments.

    Science.gov (United States)

    Jangraw, David C; Johri, Ansh; Gribetz, Meron; Sajda, Paul

    2014-09-30

    As neuroscientists endeavor to understand the brain's response to ecologically valid scenarios, many are leaving behind hyper-controlled paradigms in favor of more realistic ones. This movement has made the use of 3D rendering software an increasingly compelling option. However, mastering such software and scripting rigorous experiments requires a daunting amount of time and effort. To reduce these startup costs and make virtual environment studies more accessible to researchers, we demonstrate a naturalistic experimental design environment (NEDE) that allows experimenters to present realistic virtual stimuli while still providing tight control over the subject's experience. NEDE is a suite of open-source scripts built on the widely used Unity3D game development software, giving experimenters access to powerful rendering tools while interfacing with eye tracking and EEG, randomizing stimuli, and providing custom task prompts. Researchers using NEDE can present a dynamic 3D virtual environment in which randomized stimulus objects can be placed, allowing subjects to explore in search of these objects. NEDE interfaces with a research-grade eye tracker in real-time to maintain precise timing records and sync with EEG or other recording modalities. Python offers an alternative for experienced programmers who feel comfortable mastering and integrating the various toolboxes available. NEDE combines many of these capabilities with an easy-to-use interface and, through Unity's extensive user base, a much more substantial body of assets and tutorials. Our flexible, open-source experimental design system lowers the barrier to entry for neuroscientists interested in developing experiments in realistic virtual environments. Copyright © 2014 Elsevier B.V. All rights reserved.

  4. Automatic blood detection in capsule endoscopy video

    Czech Academy of Sciences Publication Activity Database

    Novozámský, Adam; Flusser, Jan; Tachecí, I.; Sulík, L.; Bureš, J.; Krejcar, O.

    2016-01-01

    Roč. 21, č. 12 (2016), s. 1-8, č. článku 126007. ISSN 1083-3668 R&D Projects: GA ČR GA15-16928S Institutional support: RVO:67985556 Keywords : Automatic blood detection * capsule endoscopy video Subject RIV: JD - Computer Applications, Robotics Impact factor: 2.530, year: 2016 http://library.utia.cas.cz/separaty/2016/ZOI/flusser-0466936.pdf

  5. Validation of a colour rendering index based on memory colours

    OpenAIRE

    Smet, Kevin; Jost-Boissard, Sophie; Ryckaert, Wouter; Deconinck, Geert; Hanselaer, Peter

    2010-01-01

    In this paper the performance of a colour rendering index based on memory colours is investigated in comparison with the current CIE Colour Rendering Index, the NIST Colour Quality Scale and visual appreciation results obtained at CNRS at Lyon University for a set of 3000K and 4000K LED light sources. The Pearson and Spearman correlation coefficients between each colour rendering metric and the two sets of visual results were calculated. It was found that the memory colour based colour render...

  6. Media Presentation Synchronisation for Non-monolithic Rendering Architectures

    NARCIS (Netherlands)

    I. Vaishnavi (Ishan); D.C.A. Bulterman (Dick); P.S. Cesar Garcia (Pablo Santiago); B. Gao (Bo)

    2007-01-01

    htmlabstractNon-monolithic renderers are physically distributed media playback engines. Non-monolithic renderers may use a number of different underlying network connection types to transmit media items belonging to a presentation. There is therefore a need for a media based and inter-network- type

  7. Immersive Virtual Reality for Visualization of Abdominal CT.

    Science.gov (United States)

    Lin, Qiufeng; Xu, Zhoubing; Li, Bo; Baucom, Rebeccah; Poulose, Benjamin; Landman, Bennett A; Bodenheimer, Robert E

    2013-03-28

    Immersive virtual environments use a stereoscopic head-mounted display and data glove to create high fidelity virtual experiences in which users can interact with three-dimensional models and perceive relationships at their true scale. This stands in stark contrast to traditional PACS-based infrastructure in which images are viewed as stacks of two-dimensional slices, or, at best, disembodied renderings. Although there has substantial innovation in immersive virtual environments for entertainment and consumer media, these technologies have not been widely applied in clinical applications. Here, we consider potential applications of immersive virtual environments for ventral hernia patients with abdominal computed tomography imaging data. Nearly a half million ventral hernias occur in the United States each year, and hernia repair is the most commonly performed general surgery operation worldwide. A significant problem in these conditions is communicating the urgency, degree of severity, and impact of a hernia (and potential repair) on patient quality of life. Hernias are defined by ruptures in the abdominal wall (i.e., the absence of healthy tissues) rather than a growth (e.g., cancer); therefore, understanding a hernia necessitates understanding the entire abdomen. Our environment allows surgeons and patients to view body scans at scale and interact with these virtual models using a data glove. This visualization and interaction allows users to perceive the relationship between physical structures and medical imaging data. The system provides close integration of PACS-based CT data with immersive virtual environments and creates opportunities to study and optimize interfaces for patient communication, operative planning, and medical education.

  8. Immersive virtual reality for visualization of abdominal CT

    Science.gov (United States)

    Lin, Qiufeng; Xu, Zhoubing; Li, Bo; Baucom, Rebeccah; Poulose, Benjamin; Landman, Bennett A.; Bodenheimer, Robert E.

    2013-03-01

    Immersive virtual environments use a stereoscopic head-mounted display and data glove to create high fidelity virtual experiences in which users can interact with three-dimensional models and perceive relationships at their true scale. This stands in stark contrast to traditional PACS-based infrastructure in which images are viewed as stacks of two dimensional slices, or, at best, disembodied renderings. Although there has substantial innovation in immersive virtual environments for entertainment and consumer media, these technologies have not been widely applied in clinical applications. Here, we consider potential applications of immersive virtual environments for ventral hernia patients with abdominal computed tomography imaging data. Nearly a half million ventral hernias occur in the United States each year, and hernia repair is the most commonly performed general surgery operation worldwide. A significant problem in these conditions is communicating the urgency, degree of severity, and impact of a hernia (and potential repair) on patient quality of life. Hernias are defined by ruptures in the abdominal wall (i.e., the absence of healthy tissues) rather than a growth (e.g., cancer); therefore, understanding a hernia necessitates understanding the entire abdomen. Our environment allows surgeons and patients to view body scans at scale and interact with these virtual models using a data glove. This visualization and interaction allows users to perceive the relationship between physical structures and medical imaging data. The system provides close integration of PACS-based CT data with immersive virtual environments and creates opportunities to study and optimize interfaces for patient communication, operative planning, and medical education.

  9. First progress report on the Japan Endoscopy Database project.

    Science.gov (United States)

    Kodashima, Shinya; Tanaka, Kiyohito; Matsuda, Koji; Fujishiro, Mitsuhiro; Saito, Yutaka; Ohtsuka, Kazuo; Oda, Ichiro; Katada, Chikatoshi; Kato, Masayuki; Kida, Mitsuhiro; Kobayashi, Kiyonori; Hoteya, Shu; Horimatsu, Takahiro; Matsuda, Takahisa; Muto, Manabu; Yamamoto, Hironori; Ryozawa, Shomei; Iwakiri, Ryuichi; Kutsumi, Hiromu; Miyata, Hiroaki; Kato, Mototsugu; Haruma, Ken; Fujimoto, Kazuma; Uemura, Naomi; Kaminishi, Michio; Tajiri, Hisao

    2018-01-01

    The Japan Endoscopy Database (JED) Project was started to develop the world's largest endoscopic database, capture the actual performance of endoscopic practice, and standardize the terminology and fundamental items needed for a clinical and research registry. This paper presents a progress report on the first phase of this project undertaken at eight endoscopic centers in Japan. The list of data items to be collected was drafted by the MSED-J (Minimal Standard Endoscopic Database) subcommittee. These items were aggregated offline by integrating data from two endoscopic filing systems between July 2015 and December 2015. The study population included all patients who underwent esophagogastroduodenoscopy or colonoscopy at all eight centers, patients who underwent enteroscopy at five of the eight centers, and patients who underwent endoscopic retrograde cholangiopancreatography (ERCP) at four of the eight centers. Data collected in this phase included 61 070 endoscopic procedures, of which 40 475 were esophagogastroduodenoscopies, 215 were enteroscopies, 19 204 were colonoscopies, and 1176 were ERCPs. Frequencies of complications were 0.68% for esophagogastroduodenoscopy, 0% for enteroscopy, 0.43% for colonoscopy, and 13.34% for ERCP. In addition, we obtained various data including Helicobacter pylori infection status, past history of endoscopy in patients who underwent enteroscopy or colonoscopy, and degree of difficulty of ERCP, although the frequencies of reporting were sometimes low, with some items <20%. Results of the first phase suggest that the JED project can provide vast quantities of useful data about endoscopic procedures. © 2017 Japan Gastroenterological Endoscopy Society.

  10. Gastrointestinal mucosal abnormalities using videocapsule endoscopy in systemic sclerosis.

    Science.gov (United States)

    Marie, I; Antonietti, M; Houivet, E; Hachulla, E; Maunoury, V; Bienvenu, B; Viennot, S; Smail, A; Duhaut, P; Dupas, J-L; Dominique, S; Hatron, P-Y; Levesque, H; Benichou, J; Ducrotté, P

    2014-07-01

    To date, there are no large studies on videocapsule endoscopy in systemic sclerosis (SSc). Consequently, the prevalence and features of gastrointestinal mucosal abnormalities in SSc have not been determined. To determine both prevalence and characteristics of gastrointestinal mucosal abnormalities in unselected patients with SSc, using videocapsule endoscopy. To predict which SSc patients are at risk of developing potentially bleeding gastrointestinal vascular mucosal abnormalities. Videocapsule endoscopy was performed on 50 patients with SSc. Prevalence of gastrointestinal mucosal abnormalities was 52%. Potentially bleeding vascular mucosal lesions were predominant, including: watermelon stomach (34.6%), gastric and/or small intestinal telangiectasia (26.9%) and gastric and/or small intestinal angiodysplasia (38.5%). SSc patients with gastrointestinal vascular mucosal lesions more often exhibited: limited cutaneous SSc (P = 0.06), digital ulcers (P = 0.05), higher score of nailfold videocapillaroscopy (P = 0.0009), anaemia (P = 0.02), lower levels of ferritin (P correlation between gastrointestinal vascular mucosal lesions and presence of severe extra-digestive vasculopathy (digital ulcers and higher nailfold videocapillaroscopy scores). This latter supports the theory that SSc-related diffuse vasculopathy is responsible for both cutaneous and digestive vascular lesions. Therefore, we suggest that nailfold videocapillaroscopy may be a helpful test for managing SSc patients. In fact, nailfold videocapillaroscopy score should be calculated routinely, as it may result in identification of SSc patients at higher risk of developing potentially bleeding gastrointestinal vascular mucosal lesions. © 2014 John Wiley & Sons Ltd.

  11. Extreme simplification and rendering of point sets using algebraic multigrid

    NARCIS (Netherlands)

    Reniers, D.; Telea, A.C.

    2009-01-01

    We present a novel approach for extreme simplification of point set models, in the context of real-time rendering. Point sets are often rendered using simple point primitives, such as oriented discs. However, this requires using many primitives to render even moderately simple shapes. Often, one

  12. Volume rendering in treatment planning for moving targets

    Energy Technology Data Exchange (ETDEWEB)

    Gemmel, Alexander [GSI-Biophysics, Darmstadt (Germany); Massachusetts General Hospital, Boston (United States); Wolfgang, John A.; Chen, George T.Y. [Massachusetts General Hospital, Boston (United States)

    2009-07-01

    Advances in computer technologies have facilitated the development of tools for 3-dimensional visualization of CT-data sets with volume rendering. The company Fovia has introduced a high definition volume rendering engine (HDVR trademark by Fovia Inc., Palo Alto, USA) that is capable of representing large CT data sets with high user interactivity even on standard PCs. Fovia provides a software development kit (SDK) that offers control of all the features of the rendering engine. We extended the SDK by functionalities specific to the task of treatment planning for moving tumors. This included navigation of the patient's anatomy in beam's eye view, fast point-and-click measurement of lung tumor trajectories as well as estimation of range perturbations due to motion by calculation of (differential) water equivalent path lengths for protons and carbon ions on 4D-CT data sets. We present patient examples to demonstrate the advantages and disadvantages of volume rendered images as compared to standard 2-dimensional axial plane images. Furthermore, we show an example of a range perturbation analysis. We conclude that volume rendering is a powerful technique for the representation and analysis of large time resolved data sets in treatment planning.

  13. The impact of virtual reality on implicit racial bias and mock legal decisions.

    Science.gov (United States)

    Salmanowitz, Natalie

    2018-05-01

    Implicit racial biases are one of the most vexing problems facing current society. These split-second judgments are not only widely prevalent, but also are notoriously difficult to overcome. Perhaps most concerning, implicit racial biases can have consequential impacts on decisions in the courtroom, where scholars have been unable to provide a viable mitigation strategy. This article examines the influence of a short virtual reality paradigm on implicit racial biases and evaluations of legal scenarios. After embodying a black avatar in the virtual world, participants produced significantly lower implicit racial bias scores than those who experienced a sham version of the virtual reality paradigm. Additionally, these participants more conservatively evaluated an ambiguous legal case, rating vague evidence as less indicative of guilt and rendering more Not Guilty verdicts. As the first experiment of its kind, this study demonstrates the potential of virtual reality to address implicit racial bias in the courtroom setting.

  14. The impact of virtual reality on implicit racial bias and mock legal decisions

    Science.gov (United States)

    Salmanowitz, Natalie

    2018-01-01

    Abstract Implicit racial biases are one of the most vexing problems facing current society. These split-second judgments are not only widely prevalent, but also are notoriously difficult to overcome. Perhaps most concerning, implicit racial biases can have consequential impacts on decisions in the courtroom, where scholars have been unable to provide a viable mitigation strategy. This article examines the influence of a short virtual reality paradigm on implicit racial biases and evaluations of legal scenarios. After embodying a black avatar in the virtual world, participants produced significantly lower implicit racial bias scores than those who experienced a sham version of the virtual reality paradigm. Additionally, these participants more conservatively evaluated an ambiguous legal case, rating vague evidence as less indicative of guilt and rendering more Not Guilty verdicts. As the first experiment of its kind, this study demonstrates the potential of virtual reality to address implicit racial bias in the courtroom setting. PMID:29707220

  15. Fast DRR splat rendering using common consumer graphics hardware

    International Nuclear Information System (INIS)

    Spoerk, Jakob; Bergmann, Helmar; Wanschitz, Felix; Dong, Shuo; Birkfellner, Wolfgang

    2007-01-01

    Digitally rendered radiographs (DRR) are a vital part of various medical image processing applications such as 2D/3D registration for patient pose determination in image-guided radiotherapy procedures. This paper presents a technique to accelerate DRR creation by using conventional graphics hardware for the rendering process. DRR computation itself is done by an efficient volume rendering method named wobbled splatting. For programming the graphics hardware, NVIDIAs C for Graphics (Cg) is used. The description of an algorithm used for rendering DRRs on the graphics hardware is presented, together with a benchmark comparing this technique to a CPU-based wobbled splatting program. Results show a reduction of rendering time by about 70%-90% depending on the amount of data. For instance, rendering a volume of 2x10 6 voxels is feasible at an update rate of 38 Hz compared to 6 Hz on a common Intel-based PC using the graphics processing unit (GPU) of a conventional graphics adapter. In addition, wobbled splatting using graphics hardware for DRR computation provides higher resolution DRRs with comparable image quality due to special processing characteristics of the GPU. We conclude that DRR generation on common graphics hardware using the freely available Cg environment is a major step toward 2D/3D registration in clinical routine

  16. Capsule Endoscopy in the Assessment of Obscure Gastrointestinal Bleeding: An Evidence-Based Analysis

    Science.gov (United States)

    2015-01-01

    Background Obscure gastrointestinal bleeding (OGIB) is defined as persistent or recurrent bleeding associated with negative findings on upper and lower gastrointestinal (GI) endoscopic evaluations. The diagnosis and management of patients with OGIB is particularly challenging because of the length and complex loops of the small intestine. Capsule endoscopy (CE) is 1 diagnostic modality that is used to determine the etiology of bleeding. Objectives The objective of this analysis was to review the diagnostic accuracy, safety, and impact on health outcomes of CE in patients with OGIB in comparison with other diagnostic modalities. Data Sources A literature search was performed using Ovid MEDLINE, Ovid MEDLINE In-Process and Other Non-Indexed Citations, Ovid Embase, the Wiley Cochrane Library, and the Centre for Reviews and Dissemination database, for studies published between 2007 and 2013. Review Methods Data on diagnostic accuracy, safety, and impact on health outcomes were abstracted from included studies. Quality of evidence was assessed using Grading of Recommendations Assessment, Development, and Evaluation (GRADE). Results The search yielded 1,189 citations, and 24 studies were included. Eight studies reported diagnostic accuracy comparing CE with other diagnostic modalities. Capsule endoscopy has a higher sensitivity and lower specificity than magnetic resonance enteroclysis, computed tomography, and push enteroscopy. Capsule endoscopy has a good safety profile with few adverse events, although comparative safety data with other diagnostic modalities are limited. Capsule endoscopy is associated with no difference in patient health-related outcomes such as rebleeding or follow-up treatment compared with push enteroscopy, small-bowel follow-through, and angiography. Limitations There was significant heterogeneity in estimates of diagnostic accuracy, which prohibited a statistical summary of findings. The analysis was also limited by the fact that there is no

  17. Comparison of rigid and flexible endoscopy for removing esophageal foreign bodies in an emergency.

    Science.gov (United States)

    Tseng, Chia-Chen; Hsiao, Tzu-Yu; Hsu, Wei-Chung

    2016-08-01

    Despite the effectiveness of endoscopies in removing ingested foreign bodies (FBs) impacted in the esophagus, the merits and limitations of flexible endoscopy (FE) and rigid endoscopy (RE) remain unclear. Therefore, this study compares the advantages and disadvantages of both endoscopic procedures from a clinical perspective. A retrospective review was made of 273 patients suspected of esophageal FBs in emergency consultations of a tertiary medical referral center from March 2010 to March 2014. All patients received routine physical examinations, otolaryngological examinations, and X-rays of the neck and chest. The door-to-endoscopy time, procedure time, postendoscopic hospital stay, successful removal rates, and complications were analyzed as well. In this study, the most common esophageal FBs were fish and animal bones (76%) in adults and coins (74%) in children. The patients with existing esophageal FBs had significantly more frequent symptoms of dysphagia and signs of linear opacity as detected with lateral neck radiography than those without FB. Additionally, the door-to-endoscopy time, procedure time, and postendoscopic hospital stay was significantly shorter in FE patients than in RE patients. However, both RE and FE patients had high rates of successful FB removal (95%) and low complication rates (2%). Both FE and RE remove esophageal FBs successfully, as evidenced by their high success rates, low complication rates, and high detection rates. Although FE under local anesthesia is a less time-consuming procedure for adults, RE under general anesthesia may be preferable for children and can serve as an alternative to FE. Copyright © 2015. Published by Elsevier B.V.

  18. The comparison of upper endoscopy and scintigraphy results in the diagnostics of duodenogastric reflux

    International Nuclear Information System (INIS)

    Leja, M.; Lejnieks, A.; Pokrotnieks, J.; Sosare, L.; Reinholds, E.; Brezinskis, G.; Aboltins, A.

    2002-01-01

    The results of upper endoscopy in respect to the symptoms potentially indicative for duodenogastric reflux (DGR) have been compared to the results obtained by a scintigraphic method, elaborated by the group of the authors. Altogether 89 patients (48 women, 41 men) have been studied. For the analysis of signs indicative for functional disturbances of the upper digestive symptoms (status of the lower esophageal sphincter, gastric tone, presence of bile in the gastric content, status of the pyloric sphincter, influx of the duodenal content observed during the upper endoscopy, presence of the bile in the duodenum) the maximum accepted interval between the two investigations was 24 hours, while 1 month interval was accepted for the evaluations of structural changes (esophagitis, presence of hiatal hernis, gastritis and duodenitis, deformation of the pyloric sphincter and duodenal bulb. No statistically significant correlations has been found between any of the above mentioned parameters at upper endoscopy and the presence or absence of DGR as determined by the scintigraphic method. If a influx of the duodenal content into the stomach during the upper endoscopy, this could be considered as a specific indicator (specificity - 91,3%0, while the sensitivity (16,7%) is very low. There has been a trend to decreased DGR in patients with an atrophic gastritis, still this correlation was not statistically significant. The conclusion is made that the intubation of the stomach during the upper endoscopy could be causative for artificial DGR therefore leading to incorrect data interpretation and hyper diagnostics. (authors)

  19. Clinical radiology and endoscopy of the colon

    International Nuclear Information System (INIS)

    Reeders, J.W.A.J.; Rosenbusch, G.

    1994-01-01

    Translated from the original 1993 German edition, this comprehensive volume brings together, in a logically integrated, understandable teaching text, expert imaging by radiology, up-to-date ultrasound and MRI; endoscopy, and histology. This text does justice to the importance of the colon. Such integration of disciplines represents the way medicine should be practiced and taught, and this book will be a model for other subjects in gastroenterology and other organ systems in which different complementary diagnostic techniques are used. The illustrations are of high quality, and both the black and white radiographs and the color endoscopy and histology pictures are faithfully reproduced and supported with informative legends. The condensed text, in outline form, is complemented by an abundance of well-conceived, informative, and clear diagrams, tables, and line drawings. Taken together, this format provides rapid access to all the essential facts and appearances of normal and diseased colon for the casual as well as the serious reader. For the teachers and practitioners of gastroenterology or radiology, this book provides a gold mine of facts and ideas. References have been well selected and presented in an appendix. (orig./UHE)

  20. Endoscopy services in KwaZulu-Natal Province, South Africa, are insufficient for the burden of disease: Is patient care compromised?

    Science.gov (United States)

    Loots, E; Clarke, D L; Newton, K; Mulder, C J

    2017-10-31

    Endoscopy services are central to the diagnosis and management of many gastrointestinal (GI) diseases. To evaluate the adequacy of endoscopy services in the public sector hospitals of KwaZulu-Natal (KZN) Province, South Africa, in 2016. A cross-sectional study was performed using a questionnaire completed by the clinical heads of endoscopy units in the public hospitals in KZN. The heads of 11 of the 12 endoscopy units responded. Two units were in tertiary-level hospitals and nine in regional hospitals. A total of 22 353 endoscopic procedures were performed annually, averaging 2 032 cases per annum per centre; they were performed by 89 endoscopists, of whom 72 (80.1%) were general surgeons. There were 0.06 registered gastroenterologists (GEs) per 100 000 population. Each endoscopist performed an average of 263 endoscopies per annum. There were 1.18 endoscopy rooms available per unit, and two units had on-site fluoroscopy available. The average waiting period for an upper endoscopy was 27 (range 7 - 60) days, for colonoscopy 29 (range 7 - 90) days and for duodenoscopy/endoscopic retrograde cholangiopancreatography 13 (range 4 - 20) days. This included patients with alarm symptoms for GI cancers. Equipment breakages interrupted most services, except for one hospital that had a service contract. Unit heads cited lack of equipment, trained staff and maintenance contracts as major shortcomings. Endoscopy units in KZN are not adequately equipped to deal with the endoscopy workload and services are plagued by frequent disruptions, which impact negatively on service delivery. There is a need to train more GEs. Patient care is compromised in these public hospitals.

  1. Virtual-view PSNR prediction based on a depth distortion tolerance model and support vector machine.

    Science.gov (United States)

    Chen, Fen; Chen, Jiali; Peng, Zongju; Jiang, Gangyi; Yu, Mei; Chen, Hua; Jiao, Renzhi

    2017-10-20

    Quality prediction of virtual-views is important for free viewpoint video systems, and can be used as feedback to improve the performance of depth video coding and virtual-view rendering. In this paper, an efficient virtual-view peak signal to noise ratio (PSNR) prediction method is proposed. First, the effect of depth distortion on virtual-view quality is analyzed in detail, and a depth distortion tolerance (DDT) model that determines the DDT range is presented. Next, the DDT model is used to predict the virtual-view quality. Finally, a support vector machine (SVM) is utilized to train and obtain the virtual-view quality prediction model. Experimental results show that the Spearman's rank correlation coefficient and root mean square error between the actual PSNR and the predicted PSNR by DDT model are 0.8750 and 0.6137 on average, and by the SVM prediction model are 0.9109 and 0.5831. The computational complexity of the SVM method is lower than the DDT model and the state-of-the-art methods.

  2. Virtual power plant mid-term dispatch optimization

    International Nuclear Information System (INIS)

    Pandžić, Hrvoje; Kuzle, Igor; Capuder, Tomislav

    2013-01-01

    Highlights: ► Mid-term virtual power plant dispatching. ► Linear modeling. ► Mixed-integer linear programming applied to mid-term dispatch scheduling. ► Operation profit maximization combining bilateral contracts and the day-ahead market. -- Abstract: Wind power plants incur practically zero marginal costs during their operation. However, variable and uncertain nature of wind results in significant problems when trying to satisfy the contracted quantities of delivered electricity. For this reason, wind power plants and other non-dispatchable power sources are combined with dispatchable power sources forming a virtual power plant. This paper considers a weekly self-scheduling of a virtual power plant composed of intermittent renewable sources, storage system and a conventional power plant. On the one hand, the virtual power plant needs to fulfill its long-term bilateral contracts, while, on the other hand, it acts in the market trying to maximize its overall profit. The optimal dispatch problem is formulated as a mixed-integer linear programming model which maximizes the weekly virtual power plant profit subject to the long-term bilateral contracts and technical constraints. The self-scheduling procedure is based on stochastic programming. The uncertainty of the wind power and solar power generation is settled by using pumped hydro storage in order to provide flexible operation, as well as by having a conventional power plant as a backup. The efficiency of the proposed model is rendered through a realistic case study and analysis of the results is provided. Additionally, the impact of different storage capacities and turbine/pump capacities of pumped storage are analyzed.

  3. Expanding Role of Third Space Endoscopy in the Management of Esophageal Diseases.

    Science.gov (United States)

    Yang, Dennis; Draganov, Peter V

    2018-03-01

    OPINION STATEMENT: "Third space" endoscopy, also commonly referred as submucosal endoscopy, is founded on the principle that the deeper layers of the gastrointestinal (GI) tract can be accessed by tunneling in the submucosal space without compromising the integrity of the overlying mucosa. Peroral endoscopic myotomy (POEM), endoscopic submucosal dissection (ESD), and submucosal tunneling endoscopic resection (STER) are innovative techniques within the field of third space endoscopy in the management of esophageal disorders. POEM has become an accepted minimally invasive therapy for achalasia and related motility disorders with excellent short-term results, with early studies yielding similar efficacy to surgical myotomy and increased durability when compared to pneumatic balloon dilation (PBD). Data are needed to establish long-term outcomes with POEM, with particular interest on the incidence of gastroesophageal reflux, which appears to be higher than initially anticipated. ESD, a mature endoscopic resection technique in Asia, has recently gained traction in the West as a viable option for the management of early Barrett's esophagus (BE) neoplasia. Compared to standard endoscopic mucosal resection (EMR), ESD allows the en bloc resection of lesions irrespective of size, which may facilitate histological interpretation and reduce recurrence rates. Large prospective randomized controlled trials are needed to validate the efficacy and safety of this technique and to further define its role in the endoscopic armamentarium in early BE neoplasia. STER is an attractive technique that theoretically permits the resection of subepithelial esophageal tumors (SETs) arising from the deeper GI layers. Initial studies from highly experienced endoscopic centers support its technical feasibility and safety, although these results should be interpreted with caution due to variability arising from small numbers and heterogeneity among studies. Overall, third space endoscopy is an

  4. Using Virtual Reality For Outreach Purposes in Planetology

    Science.gov (United States)

    Civet, François; Le Mouélic, Stéphane; Le Menn, Erwan; Beaunay, Stéphanie

    2016-10-01

    2016 has been a year marked by a technological breakthrough : the availability for the first time to the general public of technologically mature virtual reality devices. Virtual Reality consists in visually immerging a user in a 3D environment reproduced either from real and/or imaginary data, with the possibility to move and eventually interact with the different elements. In planetology, most of the places will remain inaccessible to the public for a while, but a fleet of dedicated spacecraft's such as orbiters, landers and rovers allow the possibility to virtually reconstruct the environments, using image processing, cartography and photogrammetry. Virtual reality can then bridge the gap to virtually "send" any user into the place and enjoy the exploration.We are investigating several type of devices to render orbital or ground based data of planetological interest, mostly from Mars. The most simple system consists of a "cardboard" headset, on which the user can simply use his cellphone as the screen. A more comfortable experience is obtained with more complex systems such as the HTC vive or Oculus Rift headsets, which include a tracking system important to minimize motion sickness. The third environment that we have developed is based on the CAVE concept, were four 3D video projectors are used to project on three 2x3m walls plus the ground. These systems can be used for scientific data analysis, but also prove to be perfectly suited for outreach and education purposes.

  5. Detection of Mucosal Recurrent Nasopharyngeal Carcinomas After Radiotherapy With Narrow-Band Imaging Endoscopy

    International Nuclear Information System (INIS)

    Wang, Wen-Hung; Lin, Yen-Chun; Chen, Wen-Cheng; Chen, Miao-Fen; Chen, Chih-Cheng; Lee, Kam-Fai

    2012-01-01

    Purpose: This study evaluated the feasibility of screening mucosal recurrent nasopharyngeal carcinoma with narrow-band imaging (NBI) endoscopy. Methods and Materials: One hundred and six patients were enrolled. All patients underwent conventional white-light (WL) endoscopic examination of the nasopharynx followed by NBI endoscopy. Biopsies were performed if recurrence was suspected. Results: We identified 32 suspected lesions by endoscopy in WL and/or NBI mode. Scattered brown spots (BS) were identified in 22 patients, and 4 of the 22 who had negative MRI findings were histopathologically confirmed to be neoplasias that were successfully removed via endoscopy. A comparison of the visualization in NBI closer view corresponded to histopathological findings in 22 BS, and the prevalence rates of neoplasias in tail signs, round signs, and irregularities signs were 0% (0/6), 0% (0/7), and 44.4% (4/9), respectively (p = 0.048). The sensitivity, specificity, and diagnostic capability were 37.5%, 92.9% and 0.652 for WL, 87.5%, 74.5% and 0.810 for NBI, and 87.5%, 87.8%, and 0.876 for NBI closer view, respectively. NBI closer view was effective in increasing specificity compared with NBI alone (87.8% vs. 74.5%, p < 0.05), and in increasing sensitivity and diagnostic capability compared to WL alone (87.5% vs. 37.5%, p < 0.05; 0.876 vs. 0.652, p = 0.0001). Conclusions: Although NBI in endoscopy can improve sensitivity of mucosal recurrent nasopharyngeal neoplasias, false-positive (nonneoplasia BS) results may be obtained in areas with nonspecific inflammatory changes due to postradiation effects. NBI closer view not only can offer a timely, convenient, and highly reliable assessment of mucosal recurrent nasopharyngeal carcinoma, it can also make endoscopic removal possible.

  6. Human-scale interaction for virtual model displays: a clear case for real tools

    Science.gov (United States)

    Williams, George C.; McDowall, Ian E.; Bolas, Mark T.

    1998-04-01

    We describe a hand-held user interface for interacting with virtual environments displayed on a Virtual Model Display. The tool, constructed entirely of transparent materials, is see-through. We render a graphical counterpart of the tool on the display and map it one-to-one with the real tool. This feature, combined with a capability for touch- sensitive, discrete input, results in a useful spatial input device that is visually versatile. We discuss the tool's design and interaction techniques it supports. Briefly, we look at the human factors issues and engineering challenges presented by this tool and, in general, by the class of hand-held user interfaces that are see-through.

  7. 3D rendering and interactive visualization technology in large industry CT

    International Nuclear Information System (INIS)

    Xiao Yongshun; Zhang Li; Chen Zhiqiang; Kang Kejun

    2002-01-01

    The author introduces the applications of interactive 3D rendering technology in the large ICT. It summarizes and comments on the iso-surfaces rendering and the direct volume rendering methods used in ICT. The author emphasizes on the technical analysis of the 3D rendering process of ICT volume data sets, and summarizes the difficulties of the inspection subsystem design in large ICT

  8. 3D rendering and interactive visualization technology in large industry CT

    International Nuclear Information System (INIS)

    Xiao Yongshun; Zhang Li; Chen Zhiqiang; Kang Kejun

    2001-01-01

    This paper introduces the applications of interactive 3D rendering technology in the large ICT. It summarizes and comments on the iso-surfaces rendering and the direct volume rendering methods used in ICT. The paper emphasizes on the technical analysis of the 3D rendering process of ICT volume data sets, and summarizes the difficulties of the inspection subsystem design in large ICT

  9. Virtual interactive presence and augmented reality (VIPAR) for remote surgical assistance.

    Science.gov (United States)

    Shenai, Mahesh B; Dillavou, Marcus; Shum, Corey; Ross, Douglas; Tubbs, Richard S; Shih, Alan; Guthrie, Barton L

    2011-03-01

    Surgery is a highly technical field that combines continuous decision-making with the coordination of spatiovisual tasks. We designed a virtual interactive presence and augmented reality (VIPAR) platform that allows a remote surgeon to deliver real-time virtual assistance to a local surgeon, over a standard Internet connection. The VIPAR system consisted of a "local" and a "remote" station, each situated over a surgical field and a blue screen, respectively. Each station was equipped with a digital viewpiece, composed of 2 cameras for stereoscopic capture, and a high-definition viewer displaying a virtual field. The virtual field was created by digitally compositing selected elements within the remote field into the local field. The viewpieces were controlled by workstations mutually connected by the Internet, allowing virtual remote interaction in real time. Digital renderings derived from volumetric MRI were added to the virtual field to augment the surgeon's reality. For demonstration, a fixed-formalin cadaver head and neck were obtained, and a carotid endarterectomy (CEA) and pterional craniotomy were performed under the VIPAR system. The VIPAR system allowed for real-time, virtual interaction between a local (resident) and remote (attending) surgeon. In both carotid and pterional dissections, major anatomic structures were visualized and identified. Virtual interaction permitted remote instruction for the local surgeon, and MRI augmentation provided spatial guidance to both surgeons. Camera resolution, color contrast, time lag, and depth perception were identified as technical issues requiring further optimization. Virtual interactive presence and augmented reality provide a novel platform for remote surgical assistance, with multiple applications in surgical training and remote expert assistance.

  10. Sonic Interactions in Virtual Reality: State of the Art, Current Challenges, and Future Directions.

    Science.gov (United States)

    Serafin, Stefania; Geronazzo, Michele; Erkut, Cumhur; Nilsson, Niels C; Nordahl, Rolf

    2018-03-01

    A high-fidelity but efficient sound simulation is an essential element of any VR experience. Many of the techniques used in virtual acoustics are graphical rendering techniques suitably modified to account for sound generation and propagation. In recent years, several advances in hardware and software technologies have been facilitating the development of immersive interactive sound-rendering experiences. In this article, we present a review of the state of the art of such simulations, with a focus on the different elements that, combined, provide a complete interactive sonic experience. This includes physics-based simulation of sound effects and their propagation in space together with binaural rendering to simulate the position of sound sources. We present how these different elements of the sound design pipeline have been addressed in the literature, trying to find the trade-off between accuracy and plausibility. Recent applications and current challenges are also presented.

  11. A Real-Time Sound Field Rendering Processor

    Directory of Open Access Journals (Sweden)

    Tan Yiyu

    2017-12-01

    Full Text Available Real-time sound field renderings are computationally intensive and memory-intensive. Traditional rendering systems based on computer simulations suffer from memory bandwidth and arithmetic units. The computation is time-consuming, and the sample rate of the output sound is low because of the long computation time at each time step. In this work, a processor with a hybrid architecture is proposed to speed up computation and improve the sample rate of the output sound, and an interface is developed for system scalability through simply cascading many chips to enlarge the simulated area. To render a three-minute Beethoven wave sound in a small shoe-box room with dimensions of 1.28 m × 1.28 m × 0.64 m, the field programming gate array (FPGA-based prototype machine with the proposed architecture carries out the sound rendering at run-time while the software simulation with the OpenMP parallelization takes about 12.70 min on a personal computer (PC with 32 GB random access memory (RAM and an Intel i7-6800K six-core processor running at 3.4 GHz. The throughput in the software simulation is about 194 M grids/s while it is 51.2 G grids/s in the prototype machine even if the clock frequency of the prototype machine is much lower than that of the PC. The rendering processor with a processing element (PE and interfaces consumes about 238,515 gates after fabricated by the 0.18 µm processing technology from the ROHM semiconductor Co., Ltd. (Kyoto Japan, and the power consumption is about 143.8 mW.

  12. Simplification of Visual Rendering in Simulated Prosthetic Vision Facilitates Navigation.

    Science.gov (United States)

    Vergnieux, Victor; Macé, Marc J-M; Jouffrais, Christophe

    2017-09-01

    Visual neuroprostheses are still limited and simulated prosthetic vision (SPV) is used to evaluate potential and forthcoming functionality of these implants. SPV has been used to evaluate the minimum requirement on visual neuroprosthetic characteristics to restore various functions such as reading, objects and face recognition, object grasping, etc. Some of these studies focused on obstacle avoidance but only a few investigated orientation or navigation abilities with prosthetic vision. The resolution of current arrays of electrodes is not sufficient to allow navigation tasks without additional processing of the visual input. In this study, we simulated a low resolution array (15 × 18 electrodes, similar to a forthcoming generation of arrays) and evaluated the navigation abilities restored when visual information was processed with various computer vision algorithms to enhance the visual rendering. Three main visual rendering strategies were compared to a control rendering in a wayfinding task within an unknown environment. The control rendering corresponded to a resizing of the original image onto the electrode array size, according to the average brightness of the pixels. In the first rendering strategy, vision distance was limited to 3, 6, or 9 m, respectively. In the second strategy, the rendering was not based on the brightness of the image pixels, but on the distance between the user and the elements in the field of view. In the last rendering strategy, only the edges of the environments were displayed, similar to a wireframe rendering. All the tested renderings, except the 3 m limitation of the viewing distance, improved navigation performance and decreased cognitive load. Interestingly, the distance-based and wireframe renderings also improved the cognitive mapping of the unknown environment. These results show that low resolution implants are usable for wayfinding if specific computer vision algorithms are used to select and display appropriate

  13. NASPGHAN Capsule Endoscopy Clinical Report.

    Science.gov (United States)

    Friedlander, Joel A; Liu, Quin Y; Sahn, Benjamin; Kooros, Koorosh; Walsh, Catharine M; Kramer, Robert E; Lightdale, Jenifer R; Khlevner, Julie; McOmber, Mark; Kurowski, Jacob; Giefer, Matthew J; Pall, Harpreet; Troendle, David M; Utterson, Elizabeth C; Brill, Herbert; Zacur, George M; Lirio, Richard A; Lerner, Diana G; Reynolds, Carrie; Gibbons, Troy E; Wilsey, Michael; Liacouras, Chris A; Fishman, Douglas S

    2017-03-01

    Wireless capsule endoscopy (CE) was introduced in 2000 as a less invasive method to visualize the distal small bowel in adults. Because this technology has advanced it has been adapted for use in pediatric gastroenterology. Several studies have described its clinical use, utility, and various training methods but pediatric literature regarding CE is limited. This clinical report developed by the Endoscopic and Procedures Committee of the North American Society of Pediatric Gastroenterology, Hepatology and Nutrition outlines the current literature, and describes the recommended current role, use, training, and future areas of research for CE in pediatrics.

  14. Blender cycles lighting and rendering cookbook

    CERN Document Server

    Iraci, Bernardo

    2013-01-01

    An in-depth guide full of step-by-step recipes to explore the concepts behind the usage of Cycles. Packed with illustrations, and lots of tips and tricks; the easy-to-understand nature of the book will help the reader understand even the most complex concepts with ease.If you are a digital artist who already knows your way around Blender, and you want to learn about the new Cycles' rendering engine, this is the book for you. Even experts will be able to pick up new tips and tricks to make the most of the rendering capabilities of Cycles.

  15. Endoscopic findings in patients presenting with dysphagia: analysis of a national endoscopy database.

    Science.gov (United States)

    Krishnamurthy, Chaya; Hilden, Kristen; Peterson, Kathryn A; Mattek, Nora; Adler, Douglas G; Fang, John C

    2012-03-01

    Dysphagia is a common problem and an indication for upper endoscopy. There is no data on the frequency of the different endoscopic findings and whether they change according to demographics or by single versus repeat endoscopy. To determine the prevalence of endoscopic findings in patients with dysphagia and whether findings differ in regard to age, gender, ethnicity, and repeat procedure. This was a retrospective study using a national endoscopic database (CORI). A total of 30,377 patients underwent esophagogastroduodenoscopy (EGD) for dysphagia of which 4,202 patients were repeat endoscopies. Overall frequency of endoscopic findings was determined by gender, age, ethnicity, and single vs. repeat procedures. Esophageal stricture was the most common finding followed by normal, esophagitis/ulcer (EU), Schatzki ring (SR), esophageal food impaction (EFI), and suspected malignancy. Males were more likely to undergo repeat endoscopies and more likely to have stricture, EU, EFI, and suspected malignancy (P = 0.001). Patients 60 years or older had a higher prevalence of stricture, EU, SR, and suspected malignancy (P findings differs significantly by gender, age, and repeat procedure. The most common findings in descending order were stricture, normal, EU, SR, EFI, and suspected malignancy. For patients undergoing a repeat procedure, normal and EU were less common and all other abnormal findings were significantly more common.

  16. Detection of active bleeding from gastric antral vascular ectasia by capsule endoscopy

    Science.gov (United States)

    Ohira, Tetsuya; Hokama, Akira; Kinjo, Nagisa; Nakamoto, Manabu; Kobashigawa, Chiharu; Kise, Yuya; Yamashiro, Satoshi; Kinjo, Fukunori; Kuniyoshi, Yukio; Fujita, Jiro

    2013-01-01

    Gastric antral vascular ectasia (GAVE) has been recognized as one of the important causes of occult and obscure gastrointestinal bleeding. The diagnosis is typically made based on the characteristic endoscopic features, including longitudinal row of flat, reddish stripes radiating from the pylorus into the antrum that resemble the stripes on a watermelon. These appearances, however, can easily be misinterpreted as moderate to severe gastritis. Although it is believed that capsule endoscopy (CE) is not helpful for the study of the stomach with its large lumen, GAVE can be more likely to be detected at CE rather than conventional endoscopy. CE can be regarded as “physiologic” endoscopy, without the need for gastric inflation and subsequent compression of the vasculature. The blood flow of the ecstatic vessels may be diminished in an inflated stomach. Therefore, GAVE may be prominent in CE. We herein describe a case of active bleeding from GAVE detected by CE and would like to emphasize a possibility that CE can improve diagnostic yields for GAVE. PMID:23515703

  17. Recent advances in head-mounted light field displays for virtual and augmented reality (Conference Presentation)

    Science.gov (United States)

    Hua, Hong

    2017-02-01

    Head-mounted light field displays render a true 3D scene by sampling either the projections of the 3D scene at different depths or the directions of the light rays apparently emitted by the 3D scene and viewed from different eye positions. They are capable of rendering correct or nearly correct focus cues and addressing the very well-known vergence-accommodation mismatch problem in conventional virtual and augmented reality displays. In this talk, I will focus on reviewing recent advancements of head-mounted light field displays for VR and AR applications. I will demonstrate examples of HMD systems developed in my group.

  18. Real-Time Location-Based Rendering of Urban Underground Pipelines

    Directory of Open Access Journals (Sweden)

    Wei Li

    2018-01-01

    Full Text Available The concealment and complex spatial relationships of urban underground pipelines present challenges in managing them. Recently, augmented reality (AR has been a hot topic around the world, because it can enhance our perception of reality by overlaying information about the environment and its objects onto the real world. Using AR, underground pipelines can be displayed accurately, intuitively, and in real time. We analyzed the characteristics of AR and their application in underground pipeline management. We mainly focused on the AR pipeline rendering procedure based on the BeiDou Navigation Satellite System (BDS and simultaneous localization and mapping (SLAM technology. First, in aiming to improve the spatial accuracy of pipeline rendering, we used differential corrections received from the Ground-Based Augmentation System to compute the precise coordinates of users in real time, which helped us accurately retrieve and draw pipelines near the users, and by scene recognition the accuracy can be further improved. Second, in terms of pipeline rendering, we used Visual-Inertial Odometry (VIO to track the rendered objects and made some improvements to visual effects, which can provide steady dynamic tracking of pipelines even in relatively markerless environments and outdoors. Finally, we used the occlusion method based on real-time 3D reconstruction to realistically express the immersion effect of underground pipelines. We compared our methods to the existing methods and concluded that the method proposed in this research improves the spatial accuracy of pipeline rendering and the portability of the equipment. Moreover, the updating of our rendering procedure corresponded with the moving of the user’s location, thus we achieved a dynamic rendering of pipelines in the real environment.

  19. Advanced Therapeutic Gastrointestinal Endoscopy in Children – Today and Tomorrow

    Directory of Open Access Journals (Sweden)

    Zaheer Nabi

    2018-03-01

    Full Text Available Gastrointestinal (GI endoscopy plays an indispensable role in the diagnosis and management of various pediatric GI disorders. While the pace of development of pediatric GI endoscopy has increased over the years, it remains sluggish compared to the advancements in GI endoscopic interventions available in adults. The predominant reasons that explain this observation include lack of formal training courses in advanced pediatric GI interventions, economic constraints in establishing a pediatric endoscopy unit, and unavailability of pediatric-specific devices and accessories. However, the situation is changing and more pediatric GI specialists are now performing complex GI procedures such as endoscopic retrograde cholangiopancreatography and endoscopic ultrasonography for various pancreatico-biliary diseases and more recently, per-oral endoscopic myotomy for achalasia cardia. Endoscopic procedures are associated with reduced morbidity and mortality compared to open surgery for GI disorders. Notable examples include chronic pancreatitis, pancreatic fluid collections, various biliary diseases, and achalasia cardia for which previously open surgery was the treatment modality of choice. A solid body of evidence supports the safety and efficacy of endoscopic management in adults. However, additions continue to be made to literature describing the pediatric population. An important consideration in children includes size of children, which in turn determines the selection of endoscopes and type of sedation that can be used for the procedure.

  20. Evaluating Environmental Sounds from a Presence Perspective for Virtual Reality Applications

    DEFF Research Database (Denmark)

    Nordahl, Rolf

    2010-01-01

    We propose a methodology to design and evaluate environmental sounds for virtual environments. We propose to combine physically modeled sound events with recorded soundscapes. Physical models are used to provide feedback to users’ actions, while soundscapes reproduce the characteristic soundmarks...... as well as self-induced interactive sounds simulated using physical models. Results show that subjects’ motion in the environment is significantly enhanced when dynamic sound sources and sound of egomotion are rendered in the environment....

  1. Low power design of wireless endoscopy compression/communication architecture

    Directory of Open Access Journals (Sweden)

    Zitouni Abdelkrim

    2018-05-01

    Full Text Available A wireless endoscopy capsule represents an efficient device interesting on the examination of digestive diseases. Many performance criteria’s (silicon area, dissipated power, image quality, computational time, etc. need to be deeply studied.In this paper, our interest is the optimization of the indicated criteria. The proposed methodology is based on exploring the advantages of the DCT/DWT transforms by combining them into single architecture. For arithmetic operations, the MCLA technique is used. This architecture integrates also a CABAC entropy coder that supports all binarization schemes. AMBA/I2C architecture is developed for assuring optimized communication.The comparisons of the proposed architecture with the most popular methods explained in related works show efficient results in terms dissipated power, hardware cost, and computation speed. Keywords: Wireless endoscopy capsule, DCT/DWT image compression, CABAC entropy coder, AMBA/I2C multi-bus architecture

  2. Wireless capsule endoscopy in adolescents with familial adenomatous polyposis.

    Science.gov (United States)

    Cavallo, Debora; Ballardini, Giovanni; Ferrari, Andrea; Delconte, Gabriele; Signoroni, Stefano; Sala, Paola; Chiaravalli, Stefano; Massimino, Maura; Bertario, Lucio; Vitellaro, Marco

    2016-01-01

    Guidelines for surveillance in patients with familial adenomatous polyposis (FAP) recommend mutation carriers to undergo periodic colorectal examination starting in the early teens. Performing colonoscopy in children may lead to complications. Wireless capsule endoscopy (WCE) has been introduced recently to evaluate both the upper and lower gastrointestinal tract, and seems suitable as a first screening examination for adolescents. The aim of this study was to evaluate the pros and cons of WCE. This was a retrospective review of a single institution database of adolescent patients with FAP identified through the Hereditary Colorectal Tumor Registry between 2007 and 2013. The main outcomes were identification of upper and lower gastrointestinal tract polyps, tolerance of the examination, and number and size of polyps. Of 46 adolescent patients with FAP, 14 (30.4%) patients carrying adenomatous polyposis coli gene (APC) mutation, 6 male and 8 female, age (median, range) 12 (10-17) years, body mass index 19 (13-24), underwent WCE as first screening examination. The examination was completed in 13 patients (93.3%). Wireless capsule endoscopy identified the duodenal papilla in 4 patients and colonic and rectal polyps in all 13 patients. In 7 patients, fewer than 25 polyps were identified. No complications were recorded related to the use of the video capsule. Wireless capsule endoscopy is feasible and well-tolerated as a first screening examination in adolescent patients. It cannot be used as alternative to the colonoscopy, but could improve compliance with colonoscopy, and increase early adherence to a surveillance program.

  3. Distributed continuous energy scheduling for dynamic virtual power plants

    International Nuclear Information System (INIS)

    Niesse, Astrid

    2015-01-01

    This thesis presents DynaSCOPE as distributed control method for continuous energy scheduling for dynamic virtual power plants (DVPP). DVPPs aggregate the flexibility of distributed energy units to address current energy markets. As an extension of the Virtual Power Plant concept they show high dynamics in aggregation and operation of energy units. Whereas operation schedules are set up for all energy units in a day-ahead planning procedure, incidents may render these schedules infeasible during execution, like deviation from prognoses or outages. Thus, a continuous scheduling process is needed to ensure product fulfillment. With DynaSCOPE, software agents representing single energy units solve this problem in a completely distributed heuristic approach. Using a stepped concept, several damping mechanisms are applied to allow minimum disturbance while continuously trying to fulfill the product as contracted at the market.

  4. Interactive 3D visualization for theoretical virtual observatories

    Science.gov (United States)

    Dykes, T.; Hassan, A.; Gheller, C.; Croton, D.; Krokos, M.

    2018-06-01

    Virtual observatories (VOs) are online hubs of scientific knowledge. They encompass a collection of platforms dedicated to the storage and dissemination of astronomical data, from simple data archives to e-research platforms offering advanced tools for data exploration and analysis. Whilst the more mature platforms within VOs primarily serve the observational community, there are also services fulfilling a similar role for theoretical data. Scientific visualization can be an effective tool for analysis and exploration of data sets made accessible through web platforms for theoretical data, which often contain spatial dimensions and properties inherently suitable for visualization via e.g. mock imaging in 2D or volume rendering in 3D. We analyse the current state of 3D visualization for big theoretical astronomical data sets through scientific web portals and virtual observatory services. We discuss some of the challenges for interactive 3D visualization and how it can augment the workflow of users in a virtual observatory context. Finally we showcase a lightweight client-server visualization tool for particle-based data sets, allowing quantitative visualization via data filtering, highlighting two example use cases within the Theoretical Astrophysical Observatory.

  5. Interactive 3D Visualization for Theoretical Virtual Observatories

    Science.gov (United States)

    Dykes, Tim; Hassan, A.; Gheller, C.; Croton, D.; Krokos, M.

    2018-04-01

    Virtual Observatories (VOs) are online hubs of scientific knowledge. They encompass a collection of platforms dedicated to the storage and dissemination of astronomical data, from simple data archives to e-research platforms offering advanced tools for data exploration and analysis. Whilst the more mature platforms within VOs primarily serve the observational community, there are also services fulfilling a similar role for theoretical data. Scientific visualization can be an effective tool for analysis and exploration of datasets made accessible through web platforms for theoretical data, which often contain spatial dimensions and properties inherently suitable for visualization via e.g. mock imaging in 2d or volume rendering in 3d. We analyze the current state of 3d visualization for big theoretical astronomical datasets through scientific web portals and virtual observatory services. We discuss some of the challenges for interactive 3d visualization and how it can augment the workflow of users in a virtual observatory context. Finally we showcase a lightweight client-server visualization tool for particle-based datasets allowing quantitative visualization via data filtering, highlighting two example use cases within the Theoretical Astrophysical Observatory.

  6. Clinical trial: a randomized trial of early endoscopy, Helicobacter pylori testing and empirical therapy for the management of dyspepsia in primary care.

    Science.gov (United States)

    Duggan, A E; Elliott, C A; Miller, P; Hawkey, C J; Logan, R F A

    2009-01-01

    Early endoscopy, Helicobacter pylori eradication and empirical acid suppression are commonly used dyspepsia management strategies in primary care but have not been directly compared in a single trial. To compare endoscopy, H. pylori test and refer, H. pylori test and treat and empirical acid suppression for dyspepsia in primary care. Patients presenting to their general practitioner with dyspepsia were randomized to endoscopy, H. pylori'test and treat', H. pylori test and endoscope positives, or empirical therapy with symptoms, patient satisfaction, healthcare costs and cost effectiveness at 12 months being the outcomes. At 2 months, the proportion of patients reporting no or minimal dyspeptic symptoms ranged from 74% for those having early endoscopy to 55% for those on empirical therapy (P = 0.009), but at 1 year, there was little difference among the four strategies. Early endoscopy was associated with fewer subsequent consultations for dyspepsia (P = 0.003). 'Test and treat' resulted in fewer endoscopies overall and was most cost-effective over a range of cost assumptions. Empirical therapy resulted in the lowest initial costs, but the highest rate of subsequent endoscopy. Gastro-oesophageal cancers were found in four patients randomized to the H. pylori testing strategies. While early endoscopy offered some advantages 'Test and treat' was the most cost-effective strategy. In older patients, early endoscopy may be an appropriate strategy in view of the greater risk of malignant disease. © 2008 The Authors. Journal compilation © 2008 Blackwell Publishing Ltd.

  7. Diagnosis of chronic rhino sinusitis in patients with cystic fibrosis: correlation between anamnesis, nasal endoscopy and computed tomography

    International Nuclear Information System (INIS)

    Boari, Leticia; Castro Junior, Ney Penteado de

    2005-01-01

    The sinonasal involvement is one of the most common manifestations in cystic fibrosis. Data show a high incidence of chronic rhino sinusitis in these patients. Although it has been found radiographic opacification of the sinus in more than 90% of cases, few are symptomatic. So that, it is difficult to recognize nasossinusal disease in patients with cystic fibrosis. Questionnaire, nasal endoscopy and CT-scan are very important methods in this approach. Aim: to evaluate the diagnosis of chronic rhino sinusitis in patients with cystic fibrosis by anamnesis, nasal endoscopy and CT-scan and compare those results.Study Design: Clinical prospective. Material and method: evaluation of 34 patients - older than 6 years and with a confirmed diagnoses of cystic fibrosis - by anamnesis (questionnaire), nasal endoscopy (score Lund-Kennedy) and CT-scan (score Lund-Mackay). Results: chronic rhino sinusitis was confirmed in: 20,58% of cases by the questionnaire, 73,52% of the cases by the nasal endoscopy and in 93,54% of the cases by the CT-scan. The results showed significant differences. The correlation between nasal endoscopy score (Lund-Kennedy score) and CT-scan score (Lund-Mackay score) was statistically significant. Conclusion: the diagnosis of chronic rhino sinusitis was statistically different between the three methods. It was higher in imaging analysis and lower in questionnaire. The nasal endoscopy is an excellent method to evaluate nasossinusal disease in cystic fibrosis. (author)

  8. Role of endoscopy in evaluating upper gastrointestinal tract lesions in rural population

    Directory of Open Access Journals (Sweden)

    Sharanabasavaraj Javali

    2015-01-01

    Full Text Available Background and Objectives: Before the advent of endoscopy direct access to the lesion for the confirmation of the diagnosis was difficult, this posed difficulty in contemplating adequate and appropriate surgery. Endoscopy as a diagnostic and therapeutic tool has grown in recent years. Upper gastrointestinal (GI endoscopy is one of the most fascinating branch which serves not only as a means of resolving or amplifying the diagnosis made clinically or by X-ray, but also a primary diagnostic procedure for conditions not otherwise diagnosable on unoperated case. Fiber optic upper GI endoscopy has already become firmly established as a reliable, quick and inexpensive tool. This study was done to detect the upper gastrointestinal lesions in rural population of Kolar District, the distribution pattern of various upper GI lesions in patients presenting with upper GI symptoms and to follow the endoscopic diagnosis for medical and surgical management. Materials and Methods: The study group includes patients reporting to outpatient department and also the inpatients in wards of General Surgery and other departments, who have upper GI symptoms, were advised endoscopy at R. L. JALAPPA Hospital and Research Centre, Kolar, from a period of December 2011 to August 2013. Results: Of the 600 cases, 370 were males, and 230 were females. Disease incidence was highest in 51-70 years age group, that is, 21.6%. Pain abdomen was the most common symptom. Epigastric tenderness was the most common sign among the patients clinically. Reflux esophagitis and diffuse gastritis formed most common cases (307 cases. The incidence of duodenitis - 7.83%, peptic ulcer -3.3%, esophageal varices - 1.5%, the incidence of carcinoma esophagus and carcinoma stomach was approximately same that is, 4.5% and 4.6% respectively. The incidence of esophageal candidiasis was 4.16%. The majority of the patients had a normal study that is, 14.5%. Conclusion: Upper GI lesions were more common in

  9. Virtual Reality as an Educational and Training Tool for Medicine.

    Science.gov (United States)

    Izard, Santiago González; Juanes, Juan A; García Peñalvo, Francisco J; Estella, Jesús Mª Gonçalvez; Ledesma, Mª José Sánchez; Ruisoto, Pablo

    2018-02-01

    Until very recently, we considered Virtual Reality as something that was very close, but it was still science fiction. However, today Virtual Reality is being integrated into many different areas of our lives, from videogames to different industrial use cases and, of course, it is starting to be used in medicine. There are two great general classifications for Virtual Reality. Firstly, we find a Virtual Reality in which we visualize a world completely created by computer, three-dimensional and where we can appreciate that the world we are visualizing is not real, at least for the moment as rendered images are improving very fast. Secondly, there is a Virtual Reality that basically consists of a reflection of our reality. This type of Virtual Reality is created using spherical or 360 images and videos, so we lose three-dimensional visualization capacity (until the 3D cameras are more developed), but on the other hand we gain in terms of realism in the images. We could also mention a third classification that merges the previous two, where virtual elements created by computer coexist with 360 images and videos. In this article we will show two systems that we have developed where each of them can be framed within one of the previous classifications, identifying the technologies used for their implementation as well as the advantages of each one. We will also analize how these systems can improve the current methodologies used for medical training. The implications of these developments as tools for teaching, learning and training are discussed.

  10. Role of Endoscopy in Diagnosis and Management of Pediatric Eosinophilic Esophagitis.

    Science.gov (United States)

    Muir, Amanda B; Merves, Jamie; Liacouras, Chris A

    2016-01-01

    Eosinophilic esophagitis (EoE) is a chronic allergic (immune-mediated) disease that leads to esophageal dysfunction and feeding disorders in children. Foods, and possibly environmental triggers, cause an inflammatory response in the esophagus, leading to esophageal inflammation, eosinophilic infiltration, and esophageal dysmotility, which may progress to dysphagia, food impaction, and esophageal stricture. Endoscopy with biopsy and histologic evaluation is currently the only method to diagnose EoE. Once diagnosed with EoE, children undergo follow-up endoscopy after therapy initiation and adjustments to ensure remission. Furthermore, children with food impactions or strictures may require endoscopic intervention such as foreign body removal and/or esophageal dilation. Copyright © 2016 Elsevier Inc. All rights reserved.

  11. Improving safety of personnel exposed to disinfectants by introducing an Endoscopy Quality Assurance Program

    OpenAIRE

    Ahmed Gado; Basel Ebeid; Aida Abdelmohsen; Anthony Axon

    2014-01-01

    Background: Chemical disinfection is the most commonly used method in gastrointestinal endoscopy reprocessing. The main problem with chemical disinfection is that it is potentially harmful to humans. Risk assessment of employees using toxic substances is recommended and the control of exposure to these substances is required. In 2003, an endoscopy quality-assurance program was instituted in a secondary care governmental hospital in Egypt. Aim: The aim of the study was to assess the risk to...

  12. Outcome of endoscopy-assisted microscopic extended transsphenoidal surgery for suprasellar craniopharyngiomas

    Directory of Open Access Journals (Sweden)

    Hidetoshi eIkeda

    2012-02-01

    Full Text Available Objectives. Craniopharyngiomas are difficult to treat. The extended transsphenoidal approach has recently been described in several small series. We describe the usefulness of microscopy-assisted angled endoscopy for visualizing vital structures such as tumor attachment or tumor invasion to the pituitary stalk to achieve confident radical tumor removal.Design and Participants. Between 2006 and 2010, 15 patients underwent the microscopy-assisted extended transsphenoidal approach for resection of entirely suprasellar craniopharyngiomas. 14 patients had the transinfundibular type, and one had the transinfundibular type with the extension to third ventricle. We observed color change within the pituitary stalk by endoscopy. The pituitary stalk was cut intentionally in ten patients, because of suspected tumor invasion surrounding the stalk. Main Outcome Measures and Results. Total removal was accomplished in nine patients. Pathological specimens from the pituitary stalk showed tumor invasion spreading over the surface of the pituitary stalk, shown by a discolored pituitary stalk, and this was essential for confident radical tumor removal. Even after stalk resection, postoperative DI was minimal when a bright signal on T1 in the posterior lobe was not confirmed on preoperative magnetic resonance imaging. Conclusion. Confident radical tumor removal is possible with the introduction of the endoscopy-assisted microscopic extended transsphenoidal approach.

  13. Image processing in radiology

    International Nuclear Information System (INIS)

    Dammann, F.

    2002-01-01

    Medical imaging processing and analysis methods have significantly improved during recent years and are now being increasingly used in clinical applications. Preprocessing algorithms are used to influence image contrast and noise. Three-dimensional visualization techniques including volume rendering and virtual endoscopy are increasingly available to evaluate sectional imaging data sets. Registration techniques have been developed to merge different examination modalities. Structures of interest can be extracted from the image data sets by various segmentation methods. Segmented structures are used for automated quantification analysis as well as for three-dimensional therapy planning, simulation and intervention guidance, including medical modelling, virtual reality environments, surgical robots and navigation systems. These newly developed methods require specialized skills for the production and postprocessing of radiological imaging data as well as new definitions of the roles of the traditional specialities. The aim of this article is to give an overview of the state-of-the-art of medical imaging processing methods, practical implications for the ragiologist's daily work and future aspects. (orig.) [de

  14. Two-Dimensional High Definition Versus Three-Dimensional Endoscopy in Endonasal Skull Base Surgery: A Comparative Preclinical Study.

    Science.gov (United States)

    Rampinelli, Vittorio; Doglietto, Francesco; Mattavelli, Davide; Qiu, Jimmy; Raffetti, Elena; Schreiber, Alberto; Villaret, Andrea Bolzoni; Kucharczyk, Walter; Donato, Francesco; Fontanella, Marco Maria; Nicolai, Piero

    2017-09-01

    Three-dimensional (3D) endoscopy has been recently introduced in endonasal skull base surgery. Only a relatively limited number of studies have compared it to 2-dimensional, high definition technology. The objective was to compare, in a preclinical setting for endonasal endoscopic surgery, the surgical maneuverability of 2-dimensional, high definition and 3D endoscopy. A group of 68 volunteers, novice and experienced surgeons, were asked to perform 2 tasks, namely simulating grasping and dissection surgical maneuvers, in a model of the nasal cavities. Time to complete the tasks was recorded. A questionnaire to investigate subjective feelings during tasks was filled by each participant. In 25 subjects, the surgeons' movements were continuously tracked by a magnetic-based neuronavigator coupled with dedicated software (ApproachViewer, part of GTx-UHN) and the recorded trajectories were analyzed by comparing jitter, sum of square differences, and funnel index. Total execution time was significantly lower with 3D technology (P < 0.05) in beginners and experts. Questionnaires showed that beginners preferred 3D endoscopy more frequently than experts. A minority (14%) of beginners experienced discomfort with 3D endoscopy. Analysis of jitter showed a trend toward increased effectiveness of surgical maneuvers with 3D endoscopy. Sum of square differences and funnel index analyses documented better values with 3D endoscopy in experts. In a preclinical setting for endonasal skull base surgery, 3D technology appears to confer an advantage in terms of time of execution and precision of surgical maneuvers. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. Emission of VOC's from modified rendering process

    International Nuclear Information System (INIS)

    Bhatti, Z.A.; Raja, I.A.; Saddique, M.; Langenhove, H.V.

    2005-01-01

    Rendering technique for processing of dead animal and slaughterhouse wastes into valuable products. It involves cooking of raw material and later Sterilization was added to reduce the Bovine Spongiform Encephalopathy (BSE). Studies have been carried out on rendering emission, with the normal cooking process. Our study shows, that the sterilization step in rendering process increases the emission of volatile organic compounds (VOC's). Gas samples, containing VOC's, were analyzed by the GC/MS (Gas Chromatograph and Mass Spectrometry). The most important groups of compounds- alcohols and cyclic hydrocarbons were identified. In the group of alcohol; 1-butanol, l-pentanol and l-hexanol compounds were found while in the group of cyclic hydrocarbon; methyl cyclopentane and cyclohexane compounds were detected. Other groups like aldehyde, sulphur containing compounds, ketone and furan were also found. Some compounds, like l-pentanol, 2-methyl propanal, dimethyl disulfide and dimethyl trisulfide, which belong to these groups, cause malodor. It is important to know these compounds to treat odorous gasses. (author)

  16. Endoscopic non-technical skills team training: the next step in quality assurance of endoscopy training.

    Science.gov (United States)

    Matharoo, Manmeet; Haycock, Adam; Sevdalis, Nick; Thomas-Gibson, Siwan

    2014-12-14

    To investigate whether novel, non-technical skills training for Bowel Cancer Screening (BCS) endoscopy teams enhanced patient safety knowledge and attitudes. A novel endoscopy team training intervention for BCS teams was developed and evaluated as a pre-post intervention study. Four multi-disciplinary BCS teams constituting BCS endoscopist(s), specialist screening practitioners, endoscopy nurses and administrative staff (A) from English BCS training centres participated. No patients were involved in this study. Expert multidisciplinary faculty delivered a single day's training utilising real clinical examples. Pre and post-course evaluation comprised participants' patient safety awareness, attitudes, and knowledge. Global course evaluations were also collected. Twenty-three participants attended and their patient safety knowledge improved significantly from 43%-55% (P ≤ 0.001) following the training intervention. 12/41 (29%) of the safety attitudes items significantly improved in the areas of perceived patient safety knowledge and awareness. The remaining safety attitude items: perceived influence on patient safety, attitudes towards error management, error management actions and personal views following an error were unchanged following training. Both qualitative and quantitative global course evaluations were positive: 21/23 (91%) participants strongly agreed/agreed that they were satisfied with the course. Qualitative evaluation included mandating such training for endoscopy teams outside BCS and incorporating team training within wider endoscopy training. Limitations of the study include no measure of increased patient safety in clinical practice following training. A novel comprehensive training package addressing patient safety, non-technical skills and adverse event analysis was successful in improving multi-disciplinary teams' knowledge and safety attitudes.

  17. Endoscopic non-technical skills team training: The next step in quality assurance of endoscopy training

    Science.gov (United States)

    Matharoo, Manmeet; Haycock, Adam; Sevdalis, Nick; Thomas-Gibson, Siwan

    2014-01-01

    AIM: To investigate whether novel, non-technical skills training for Bowel Cancer Screening (BCS) endoscopy teams enhanced patient safety knowledge and attitudes. METHODS: A novel endoscopy team training intervention for BCS teams was developed and evaluated as a pre-post intervention study. Four multi-disciplinary BCS teams constituting BCS endoscopist(s), specialist screening practitioners, endoscopy nurses and administrative staff (A) from English BCS training centres participated. No patients were involved in this study. Expert multidisciplinary faculty delivered a single day’s training utilising real clinical examples. Pre and post-course evaluation comprised participants’ patient safety awareness, attitudes, and knowledge. Global course evaluations were also collected. RESULTS: Twenty-three participants attended and their patient safety knowledge improved significantly from 43%-55% (P ≤ 0.001) following the training intervention. 12/41 (29%) of the safety attitudes items significantly improved in the areas of perceived patient safety knowledge and awareness. The remaining safety attitude items: perceived influence on patient safety, attitudes towards error management, error management actions and personal views following an error were unchanged following training. Both qualitative and quantitative global course evaluations were positive: 21/23 (91%) participants strongly agreed/agreed that they were satisfied with the course. Qualitative evaluation included mandating such training for endoscopy teams outside BCS and incorporating team training within wider endoscopy training. Limitations of the study include no measure of increased patient safety in clinical practice following training. CONCLUSION: A novel comprehensive training package addressing patient safety, non-technical skills and adverse event analysis was successful in improving multi-disciplinary teams’ knowledge and safety attitudes. PMID:25516665

  18. High definition versus standard definition white light endoscopy for detecting dysplasia in patients with Barrett's esophagus.

    Science.gov (United States)

    Sami, S S; Subramanian, V; Butt, W M; Bejkar, G; Coleman, J; Mannath, J; Ragunath, K

    2015-01-01

    High-definition endoscopy systems provide superior image resolution. The aim of this study was to assess the utility of high definition compared with standard definition endoscopy system for detecting dysplastic lesions in patients with Barrett's esophagus. A retrospective cohort study of patients with non-dysplastic Barrett's esophagus undergoing routine surveillance was performed. Data were retrieved from the central hospital electronic database. Procedures performed for non-surveillance indications, Barrett's esophagus Prague C0M1 classification with no specialized intestinal metaplasia on histology, patients diagnosed with any dysplasia or cancer on index endoscopy, and procedures using advanced imaging techniques were excluded. Logistic regression models were constructed to estimate adjusted odds ratios and 95% confidence intervals comparing outcomes with standard definition and high-definition systems. The high definition was superior to standard definition system in targeted detection of all dysplastic lesions (odds ratio 3.27, 95% confidence interval 1.27-8.40) as well as overall dysplasia detected on both random and target biopsies (odds ratio 2.36, 95% confidence interval 1.50-3.72). More non-dysplastic lesions were detected with the high-definition system (odds ratio 1.16, 95% confidence interval 1.01-1.33). There was no difference between high definition and standard definition endoscopy in the overall (random and target) high-grade dysplasia or cancers detected (odds ratio 0.93, 95% confidence interval 0.83-1.04). Trainee endoscopists, number of biopsies taken, and male sex were all significantly associated with a higher yield for dysplastic lesions. The use of the high-definition endoscopy system is associated with better targeted detection of any dysplasia during routine Barrett's esophagus surveillance. However, high-definition endoscopy cannot replace random biopsies at present time. © 2014 International Society for Diseases of the Esophagus.

  19. A kinesthetic washout filter for force-feedback rendering.

    Science.gov (United States)

    Danieau, Fabien; Lecuyer, Anatole; Guillotel, Philippe; Fleureau, Julien; Mollet, Nicolas; Christie, Marc

    2015-01-01

    Today haptic feedback can be designed and associated to audiovisual content (haptic-audiovisuals or HAV). Although there are multiple means to create individual haptic effects, the issue of how to properly adapt such effects on force-feedback devices has not been addressed and is mostly a manual endeavor. We propose a new approach for the haptic rendering of HAV, based on a washout filter for force-feedback devices. A body model and an inverse kinematics algorithm simulate the user's kinesthetic perception. Then, the haptic rendering is adapted in order to handle transitions between haptic effects and to optimize the amplitude of effects regarding the device capabilities. Results of a user study show that this new haptic rendering can successfully improve the HAV experience.

  20. Construction and Optimization of Three-Dimensional Disaster Scenes within Mobile Virtual Reality

    Directory of Open Access Journals (Sweden)

    Ya Hu

    2018-06-01

    Full Text Available Because mobile virtual reality (VR is both mobile and immersive, three-dimensional (3D visualizations of disaster scenes based in mobile VR enable users to perceive and recognize disaster environments faster and better than is possible with other methods. To achieve immersion and prevent users from feeling dizzy, such visualizations require a high scene-rendering frame rate. However, the existing related visualization work cannot provide a sufficient solution for this purpose. This study focuses on the construction and optimization of a 3D disaster scene in order to satisfy the high frame-rate requirements for the rendering of 3D disaster scenes in mobile VR. First, the design of a plugin-free browser/server (B/S architecture for 3D disaster scene construction and visualization based in mobile VR is presented. Second, certain key technologies for scene optimization are discussed, including diverse modes of scene data representation, representation optimization of mobile scenes, and adaptive scheduling of mobile scenes. By means of these technologies, smartphones with various performance levels can achieve higher scene-rendering frame rates and improved visual quality. Finally, using a flood disaster as an example, a plugin-free prototype system was developed, and experiments were conducted. The experimental results demonstrate that a 3D disaster scene constructed via the methods addressed in this study has a sufficiently high scene-rendering frame rate to satisfy the requirements for rendering a 3D disaster scene in mobile VR.

  1. Post-processing methods of rendering and visualizing 3-D reconstructed tomographic images

    Energy Technology Data Exchange (ETDEWEB)

    Wong, S.T.C. [Univ. of California, San Francisco, CA (United States)

    1997-02-01

    The purpose of this presentation is to discuss the computer processing techniques of tomographic images, after they have been generated by imaging scanners, for volume visualization. Volume visualization is concerned with the representation, manipulation, and rendering of volumetric data. Since the first digital images were produced from computed tomography (CT) scanners in the mid 1970s, applications of visualization in medicine have expanded dramatically. Today, three-dimensional (3D) medical visualization has expanded from using CT data, the first inherently digital source of 3D medical data, to using data from various medical imaging modalities, including magnetic resonance scanners, positron emission scanners, digital ultrasound, electronic and confocal microscopy, and other medical imaging modalities. We have advanced from rendering anatomy to aid diagnosis and visualize complex anatomic structures to planning and assisting surgery and radiation treatment. New, more accurate and cost-effective procedures for clinical services and biomedical research have become possible by integrating computer graphics technology with medical images. This trend is particularly noticeable in current market-driven health care environment. For example, interventional imaging, image-guided surgery, and stereotactic and visualization techniques are now stemming into surgical practice. In this presentation, we discuss only computer-display-based approaches of volumetric medical visualization. That is, we assume that the display device available is two-dimensional (2D) in nature and all analysis of multidimensional image data is to be carried out via the 2D screen of the device. There are technologies such as holography and virtual reality that do provide a {open_quotes}true 3D screen{close_quotes}. To confine the scope, this presentation will not discuss such approaches.

  2. Post-processing methods of rendering and visualizing 3-D reconstructed tomographic images

    International Nuclear Information System (INIS)

    Wong, S.T.C.

    1997-01-01

    The purpose of this presentation is to discuss the computer processing techniques of tomographic images, after they have been generated by imaging scanners, for volume visualization. Volume visualization is concerned with the representation, manipulation, and rendering of volumetric data. Since the first digital images were produced from computed tomography (CT) scanners in the mid 1970s, applications of visualization in medicine have expanded dramatically. Today, three-dimensional (3D) medical visualization has expanded from using CT data, the first inherently digital source of 3D medical data, to using data from various medical imaging modalities, including magnetic resonance scanners, positron emission scanners, digital ultrasound, electronic and confocal microscopy, and other medical imaging modalities. We have advanced from rendering anatomy to aid diagnosis and visualize complex anatomic structures to planning and assisting surgery and radiation treatment. New, more accurate and cost-effective procedures for clinical services and biomedical research have become possible by integrating computer graphics technology with medical images. This trend is particularly noticeable in current market-driven health care environment. For example, interventional imaging, image-guided surgery, and stereotactic and visualization techniques are now stemming into surgical practice. In this presentation, we discuss only computer-display-based approaches of volumetric medical visualization. That is, we assume that the display device available is two-dimensional (2D) in nature and all analysis of multidimensional image data is to be carried out via the 2D screen of the device. There are technologies such as holography and virtual reality that do provide a open-quotes true 3D screenclose quotes. To confine the scope, this presentation will not discuss such approaches

  3. Therapeutic Endoscopy for the Control of Nonvariceal Upper Gastrointestinal Bleeding in Children: A Case Series.

    Science.gov (United States)

    Banc-Husu, Anna M; Ahmad, Nuzhat A; Chandrasekhara, Vinay; Ginsberg, Gregory G; Jaffe, David L; Kochman, Michael L; Rajala, Michael W; Mamula, Petar

    2017-04-01

    Gastrointestinal bleeding is one of the most common indications for urgent endoscopy in the pediatric setting. The majority of these procedures are performed for control of variceal bleeding, with few performed for nonvariceal upper gastrointestinal (NVUGI) bleeding. The data on therapeutic endoscopy for NVUGI are sparse. The aims of our study were to review our experience with NVUGI bleeding, describe technical aspects and outcomes of therapeutic endoscopy, and determine gastroenterology fellows' training opportunities according to the national training guidelines. We performed a retrospective review of endoscopy database (Endoworks, Olympus Inc, Center Valley, PA) from January 2009 to December 2014. The search used the following keywords: bleeding, hematemesis, melena, injection, epinephrine, cautery, clip, and argon plasma coagulation. The collected data included demographics, description of bleeding lesion and medical/endoscopic therapy, rate of rebleeding, relevant laboratories, physical examination, and need for transfusion and surgery. The study was approved by the institutional review board. During the study period 12,737 upper endoscopies (esophagogastroduodenoscopies) were performed. A total of 15 patients underwent 17 esophagogastroduodenoscopies that required therapeutic intervention to control bleeding (1:750 procedures). The mean ± standard deviation (median) age of patients who required endoscopic intervention was 11.6 ± 6.0 years (14.0 years). Seven out of 17 patients received dual therapy to control the bleeding lesions. All but 3 patients received medical therapy with intravenous proton pump inhibitor, and 3 received octreotide infusions. Six of the patients experienced rebleeding (40%), with 4 out of 6 initially only receiving single modality therapy. Two of these patients eventually required surgical intervention to control bleeding and both patients presented with bleeding duodenal ulcers. There were no cases of aspiration

  4. Processing-in-Memory Enabled Graphics Processors for 3D Rendering

    Energy Technology Data Exchange (ETDEWEB)

    Xie, Chenhao; Song, Shuaiwen; Wang, Jing; Zhang, Weigong; Fu, Xin

    2017-02-06

    The performance of 3D rendering of Graphics Processing Unit that convents 3D vector stream into 2D frame with 3D image effects significantly impact users’ gaming experience on modern computer systems. Due to the high texture throughput in 3D rendering, main memory bandwidth becomes a critical obstacle for improving the overall rendering performance. 3D stacked memory systems such as Hybrid Memory Cube (HMC) provide opportunities to significantly overcome the memory wall by directly connecting logic controllers to DRAM dies. Based on the observation that texel fetches significantly impact off-chip memory traffic, we propose two architectural designs to enable Processing-In-Memory based GPU for efficient 3D rendering.

  5. Endoscopy and antiplatelet agents. European Society of Gastrointestinal Endoscopy (ESGE) Guideline.

    Science.gov (United States)

    Boustière, C; Veitch, A; Vanbiervliet, G; Bulois, P; Deprez, P; Laquiere, A; Laugier, R; Lesur, G; Mosler, P; Nalet, B; Napoleon, B; Rembacken, B; Ajzenberg, N; Collet, J P; Baron, T; Dumonceau, J-M

    2011-05-01

    With the increasing use of antiplatelet agents (APA), their management during the periendoscopic period has become a more common and more difficult problem. The increase in use is due to the availability of new drugs and the widespread use of drug-eluting coronary stents. Acute coronary syndromes can occur when APA therapy is withheld for noncardiovascular interventions. Guidelines about APA management during the periendoscopic period are traditionally based on assessments of the procedure-related risk of bleeding and the risk of thrombosis if APA are stopped. New data allow better assessment of these risks, of the necessary duration of APA discontinuation before endoscopy, of the use of alternative procedures (mostly for endoscopic retrograde cholangiopancreatography [ERCP]), and of endoscopic methods that can be used to prevent bleeding (following colonic polypectomy). This guideline makes graded, evidence-based, recommendations for the management of APA for all currently performed endoscopic procedures. A short summary and two tables are included for quick reference. © Georg Thieme Verlag KG Stuttgart · New York.

  6. RAY TRACING RENDER MENGGUNAKAN FRAGMENT ANTI ALIASING

    Directory of Open Access Journals (Sweden)

    Febriliyan Samopa

    2008-07-01

    Full Text Available Normal 0 false false false IN X-NONE X-NONE MicrosoftInternetExplorer4 /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-qformat:yes; mso-style-parent:""; mso-padding-alt:0cm 5.4pt 0cm 5.4pt; mso-para-margin-top:0cm; mso-para-margin-right:0cm; mso-para-margin-bottom:10.0pt; mso-para-margin-left:0cm; line-height:115%; mso-pagination:widow-orphan; font-size:11.0pt; font-family:"Calibri","sans-serif"; mso-ascii-font-family:Calibri; mso-ascii-theme-font:minor-latin; mso-fareast-font-family:"Times New Roman"; mso-fareast-theme-font:minor-fareast; mso-hansi-font-family:Calibri; mso-hansi-theme-font:minor-latin; mso-bidi-font-family:"Times New Roman"; mso-bidi-theme-font:minor-bidi;} Rendering is generating surface and three-dimensional effects on an object displayed on a monitor screen. Ray tracing as a rendering method that traces ray for each image pixel has a drawback, that is, aliasing (jaggies effect. There are some methods for executing anti aliasing. One of those methods is OGSS (Ordered Grid Super Sampling. OGSS is able to perform aliasing well. However, this method requires more computation time since sampling of all pixels in the image will be increased. Fragment Anti Aliasing (FAA is a new alternative method that can cope with the drawback. FAA will check the image when performing rendering to a scene. Jaggies effect is only happened at curve and gradient object. Therefore, only this part of object that will experience sampling magnification. After this sampling magnification and the pixel values are computed, then downsample is performed to retrieve the original pixel values. Experimental results show that the software can implement ray tracing well in order to form images, and it can implement FAA and OGSS technique to perform anti aliasing. In general, rendering using FAA is faster than using OGSS

  7. Evaluation of capsule endoscopy to detect mucosal lesions associated with gastrointestinal bleeding in dogs.

    Science.gov (United States)

    Davignon, D L; Lee, A C Y; Johnston, A N; Bowman, D D; Simpson, K W

    2016-03-01

    The objective of this study was to examine the utility of capsule endoscopy to detect mucosal abnormalities in dogs with gastrointestinal haemorrhage. Capsules were administered to 2 healthy controls and 8 patients with gastrointestinal haemorrhage. Images were evaluated for quality, gastric emptying time, small intestinal transit time and presence of lesions. There were no adverse effects of capsule endoscopy in dogs weighing from 7·7 to 58 kg. The capsule traversed the entire gastrointestinal tract in 5 of 8 patients, with high quality images obtained in the stomach and small intestine. Gastric emptying time and small intestinal transit time ranged from 1 to 270 and 15 to 180 minutes, respectively. In 3 of 8 patients, the capsule remained in the stomach despite pro-kinetics. Gastric lesions included mild haemorrhage and pinpoint erosion (4 of 8), a mass (1) and thickened bleeding pyloric mucosa (2). Two of 3 dogs with capsule retention had gastric lesions. Intestinal lesions included a healing duodenal ulcer, abnormal villi, ileal ulceration and colonic bleeding. Lesions identified by capsule endoscopy were considered a significant source of haemorrhage in 4 of 7 dogs with active bleeding. The relevance of pinpoint gastric mucosal erosions to blood loss is unclear. Capsule endoscopy can enable the non-invasive detection of gastric and small intestinal mucosal lesions in dogs presenting for evaluation of gastrointestinal bleeding. © 2016 British Small Animal Veterinary Association.

  8. A VIRTUAL GLOBE-BASED MULTI-RESOLUTION TIN SURFACE MODELING AND VISUALIZETION METHOD

    Directory of Open Access Journals (Sweden)

    X. Zheng

    2016-06-01

    Full Text Available The integration and visualization of geospatial data on a virtual globe play an significant role in understanding and analysis of the Earth surface processes. However, the current virtual globes always sacrifice the accuracy to ensure the efficiency for global data processing and visualization, which devalue their functionality for scientific applications. In this article, we propose a high-accuracy multi-resolution TIN pyramid construction and visualization method for virtual globe. Firstly, we introduce the cartographic principles to formulize the level of detail (LOD generation so that the TIN model in each layer is controlled with a data quality standard. A maximum z-tolerance algorithm is then used to iteratively construct the multi-resolution TIN pyramid. Moreover, the extracted landscape features are incorporated into each-layer TIN, thus preserving the topological structure of terrain surface at different levels. In the proposed framework, a virtual node (VN-based approach is developed to seamlessly partition and discretize each triangulation layer into tiles, which can be organized and stored with a global quad-tree index. Finally, the real time out-of-core spherical terrain rendering is realized on a virtual globe system VirtualWorld1.0. The experimental results showed that the proposed method can achieve an high-fidelity terrain representation, while produce a high quality underlying data that satisfies the demand for scientific analysis.

  9. Self-expandable metal stents for obstructing colonic and extracolonic cancer: European Society of Gastrointestinal Endoscopy (ESGE) Clinical Guideline

    NARCIS (Netherlands)

    van Hooft, Jeanin E.; van Halsema, Emo E.; Vanbiervliet, Geoffroy; Beets-Tan, Regina G. H.; Dewitt, John M.; Donnellan, Fergal; Dumonceau, Jean-Marc; Glynne-Jones, Robert G. T.; Hassan, Cesare; Jiménez-Perez, Javier; Meisner, Søren; Muthusamy, V. Raman; Parker, Michael C.; Regimbeau, Jean-Marc; Sabbagh, Charles; Sagar, Jayesh; Tanis, Pieter J.; Vandervoort, Jo; Webster, George J.; Manes, Gianpiero; Barthet, Marc A.; Repici, Alessandro

    2014-01-01

    This Guideline is an official statement of the European Society of Gastrointestinal Endoscopy (ESGE). This Guideline was also reviewed and endorsed by the Governing Board of the American Society for Gastrointestinal Endoscopy (ASGE). The Grading of Recommendations Assessment, Development, and

  10. Self-Expandable Metal Stents for Obstructing Colonic and Extracolonic Cancer: European Society of Gastrointestinal Endoscopy (ESGE) Clinical Guideline

    NARCIS (Netherlands)

    van Hooft, J. E.; van Halsema, E. E.; Vanbiervliet, G.; Beets-Tan, R. G. H.; DeWitt, J. M.; Donnellan, F.; Dumonceau, J. M.; Glynne-Jones, R. G. T.; Hassan, C.; Jimenez-Perez, J.; Meisner, S.; Muthusamy, V. Raman; Parker, M. C.; Regimbeau, J. M.; Sabbagh, C.; Sagar, J.; Tanis, P. J.; Vandervoort, J.; Webster, G. J.; Manes, G.; Barthet, M. A.; Repici, A.

    2014-01-01

    This Guideline is an official statement of the European Society of Gastrointestinal Endoscopy (ESGE). This Guideline was also reviewed and endorsed by the Governing Board of the American Society for Gastrointestinal Endoscopy (ASGE). The Grading of Recommendations Assessment, Development, and

  11. The influence of non-rigid anatomy and patient positioning on endoscopy-CT image registration in the head and neck.

    Science.gov (United States)

    Ingram, W Scott; Yang, Jinzhong; Wendt, Richard; Beadle, Beth M; Rao, Arvind; Wang, Xin A; Court, Laurence E

    2017-08-01

    To assess the influence of non-rigid anatomy and differences in patient positioning between CT acquisition and endoscopic examination on endoscopy-CT image registration in the head and neck. Radiotherapy planning CTs and 31-35 daily treatment-room CTs were acquired for nineteen patients. Diagnostic CTs were acquired for thirteen of the patients. The surfaces of the airways were segmented on all scans and triangular meshes were created to render virtual endoscopic images with a calibrated pinhole model of an endoscope. The virtual images were used to take projective measurements throughout the meshes, with reference measurements defined as those taken on the planning CTs and test measurements defined as those taken on the daily or diagnostic CTs. The influence of non-rigid anatomy was quantified by 3D distance errors between reference and test measurements on the daily CTs, and the influence of patient positioning was quantified by 3D distance errors between reference and test measurements on the diagnostic CTs. The daily CT measurements were also used to investigate the influences of camera-to-surface distance, surface angle, and the interval of time between scans. Average errors in the daily CTs were 0.36 ± 0.61 cm in the nasal cavity, 0.58 ± 0.83 cm in the naso- and oropharynx, and 0.47 ± 0.73 cm in the hypopharynx and larynx. Average errors in the diagnostic CTs in those regions were 0.52 ± 0.69 cm, 0.65 ± 0.84 cm, and 0.69 ± 0.90 cm, respectively. All CTs had errors heavily skewed towards 0, albeit with large outliers. Large camera-to-surface distances were found to increase the errors, but the angle at which the camera viewed the surface had no effect. The errors in the Day 1 and Day 15 CTs were found to be significantly smaller than those in the Day 30 CTs (P projective measurement errors. In general, these errors are largest when the camera is in the superior pharynx, where it sees large distances and a lot of muscle motion. The

  12. Digital color acquisition, perception, coding and rendering

    CERN Document Server

    Fernandez-Maloigne, Christine; Macaire, Ludovic

    2013-01-01

    In this book the authors identify the basic concepts and recent advances in the acquisition, perception, coding and rendering of color. The fundamental aspects related to the science of colorimetry in relation to physiology (the human visual system) are addressed, as are constancy and color appearance. It also addresses the more technical aspects related to sensors and the color management screen. Particular attention is paid to the notion of color rendering in computer graphics. Beyond color, the authors also look at coding, compression, protection and quality of color images and videos.

  13. Challenges to the development of complex virtual reality surgical simulations.

    Science.gov (United States)

    Seymour, N E; Røtnes, J S

    2006-11-01

    Virtual reality simulation in surgical training has become more widely used and intensely investigated in an effort to develop safer, more efficient, measurable training processes. The development of virtual reality simulation of surgical procedures has begun, but well-described technical obstacles must be overcome to permit varied training in a clinically realistic computer-generated environment. These challenges include development of realistic surgical interfaces and physical objects within the computer-generated environment, modeling of realistic interactions between objects, rendering of the surgical field, and development of signal processing for complex events associated with surgery. Of these, the realistic modeling of tissue objects that are fully responsive to surgical manipulations is the most challenging. Threats to early success include relatively limited resources for development and procurement, as well as smaller potential for return on investment than in other simulation industries that face similar problems. Despite these difficulties, steady progress continues to be made in these areas. If executed properly, virtual reality offers inherent advantages over other training systems in creating a realistic surgical environment and facilitating measurement of surgeon performance. Once developed, complex new virtual reality training devices must be validated for their usefulness in formative training and assessment of skill to be established.

  14. Three-dimensional spiral CT during arterial portography: comparison of three rendering techniques.

    Science.gov (United States)

    Heath, D G; Soyer, P A; Kuszyk, B S; Bliss, D F; Calhoun, P S; Bluemke, D A; Choti, M A; Fishman, E K

    1995-07-01

    The three most common techniques for three-dimensional reconstruction are surface rendering, maximum-intensity projection (MIP), and volume rendering. Surface-rendering algorithms model objects as collections of geometric primitives that are displayed with surface shading. The MIP algorithm renders an image by selecting the voxel with the maximum intensity signal along a line extended from the viewer's eye through the data volume. Volume-rendering algorithms sum the weighted contributions of all voxels along the line. Each technique has advantages and shortcomings that must be considered during selection of one for a specific clinical problem and during interpretation of the resulting images. With surface rendering, sharp-edged, clear three-dimensional reconstruction can be completed on modest computer systems; however, overlapping structures cannot be visualized and artifacts are a problem. MIP is computationally a fast technique, but it does not allow depiction of overlapping structures, and its images are three-dimensionally ambiguous unless depth cues are provided. Both surface rendering and MIP use less than 10% of the image data. In contrast, volume rendering uses nearly all of the data, allows demonstration of overlapping structures, and engenders few artifacts, but it requires substantially more computer power than the other techniques.

  15. Computerisation of endoscopy reports using standard reports and text blocks

    NARCIS (Netherlands)

    Groenen, M. J. M.; Kuipers, E. J.; van Berge Henegouwen, G. P.; Fockens, P.; Ouwendijk, R. J. Th

    2006-01-01

    BACKGROUND: The widespread use of gastrointestinal endoscopy for diagnosis and treatment requires effective, standardised report systems. This need is further increased by the limited storage of images, and by the need for structured databases for surveillance and epidemiology. We therefore aimed

  16. Upper gastrointestinal diseases in patients for endoscopy in South ...

    African Journals Online (AJOL)

    The most common endoscopy finding was gastritis (40.2%), followed by normal examination (15.2%), oesophageal cancer (13.6%), gastric ulcer (7.6%) and gastric cancer (7.1%). Patients older than 40 years (n=110) had significant findings including gastritis (50.9%), oesophageal cancer (22.7%) and gastric cancer ...

  17. A score card for upper GI endoscopy: Evaluation of interobserver variability in examiners with various levels of experience.

    Science.gov (United States)

    Neumann, M; Friedl, S; Meining, A; Egger, K; Heldwein, W; Rey, J F; Hochberger, J; Classen, M; Hohenberger, W; Rösch, T

    2002-10-01

    In most European countries, training in GI endoscopy has largely been based on hands-on acquisition of experience in patients rather than on a structured training programme. With the development of training models systematic hands-on training in a variety of diagnostic and therapeutic endoscopy techniques was achieved. Little, however, is known about methods of objectively assessing trainees' performance. We therefore developed an assessment 'score card' for upper GI endoscopy and tested it in endoscopists with various levels of experience. The aim of the study was therefore to assess interobserver variations in the evaluation of trainees. On the basis of textbook and expert opinions a consensus group of eight experienced endoscopists developed a score card for diagnostic upper GI endoscopy with biopsy. The score card includes an assessment of the single steps of the procedure as well as of the times needed to complete each step. This score card was then evaluated in a further conference including ten experts who blindly assessed videotapes of 15 endoscopists performing upper GI endoscopy in a training bio-simulation model (the 'Erlangen Endo-Trainer'). On the basis of their previous experience (i. e. the number of endoscopies performed) these 15 endoscopists were classified into four groups: very experienced, experienced, having some experience and inexperienced. Interobserver variability (IOV) was tested for the various score card parameters (Kendall's rank-correlation coefficient 0.0-0.5 poor, 0.5-1.0 good agreement). In addition, the correlation between the score card assessment and the examiners' experience levels was analysed. Despite poor IOV results for all the parameters tested (Kendall coefficient account (correlation coefficient 0.59-0.89, p < 0.05). The score card parameters were suitable for differentiating between the four groups of examiners with different levels of endoscopic experience. As expected with scores involving subjective assessment of

  18. Stray energy transfer during endoscopy.

    Science.gov (United States)

    Jones, Edward L; Madani, Amin; Overbey, Douglas M; Kiourti, Asimina; Bojja-Venkatakrishnan, Satheesh; Mikami, Dean J; Hazey, Jeffrey W; Arcomano, Todd R; Robinson, Thomas N

    2017-10-01

    Endoscopy is the standard tool for the evaluation and treatment of gastrointestinal disorders. While the risk of complication is low, the use of energy devices can increase complications by 100-fold. The mechanism of increased injury and presence of stray energy is unknown. The purpose of the study was to determine if stray energy transfer occurs during endoscopy and if so, to define strategies to minimize the risk of energy complications. A gastroscope was introduced into the stomach of an anesthetized pig. A monopolar generator delivered energy for 5 s to a snare without contacting tissue or the endoscope itself. The endoscope tip orientation, energy device type, power level, energy mode, and generator type were varied to mimic in vivo use. The primary outcome (stray current) was quantified as the change in tissue temperature (°C) from baseline at the tissue closest to the tip of the endoscope. Data were reported as mean ± standard deviation. Using the 60 W coag mode while changing the orientation of the endoscope tip, tissue temperature increased by 12.1 ± 3.5 °C nearest the camera lens (p energy transfer (p = 0.04 and p = 0.002, respectively) as did utilizing the low-voltage cut mode (6.6 ± 0.5 °C, p energy transfer compared to a standard generator (1.5 ± 3.5 °C vs. 9.5 ± 0.8 °C, p energy is transferred within the endoscope during the activation of common energy devices. This could result in post-polypectomy syndrome, bleeding, or perforation outside of the endoscopist's view. Decreasing the power, utilizing low-voltage modes and/or an impedance-monitoring generator can decrease the risk of complication.

  19. Lidocaine lozenges for pharyngeal anesthesia during upper gastrointestinal endoscopy: A randomized controlled trial

    Directory of Open Access Journals (Sweden)

    Avinash Supe

    2014-01-01

    Full Text Available Background and Objectives: A novel lozenge formulation with advantages of ease of drug administration, palatable taste and improved patient compliance could be the preferred mode of topical pharyngeal anesthesia during upper gastrointestinal endoscopy (UGE. This randomized, open-label, active-controlled study was conducted to evaluate the efficacy and safety of lidocaine lozenges versus lidocaine spray in the diagnostic gastroduodenal endoscopy in Indian patients. Subjects and Methods: Two hundred and forty-seven patients of either sex (18-80 years undergoing diagnostic gastroduodenal endoscopy were randomized either to; lidocaine lozenge 200 mg or lidocaine spray 200 mg to be applied as a single dose before gastroduodenal endoscopy. Ease of procedure, level of gag reflex, ease of application of the local anesthetic, and investigators global assessment were the primary efficacy endpoints. Need for rescue medication and patient′s global assessment were secondary efficacy endpoints. The incidence of any adverse event was the safety endpoint. Between groups, comparison was done by using appropriate statistical test. Results: Investigator reported significantly lesser procedural difficulty (P = 0.0007 and suppressed gag reflex (P < 0.0001 during UGE with lidocaine lozenge compared to spray. Ease of application of local anesthetic was reported easy in significantly more patients as compared with lidocaine spray (P = 0.001. Global assessment by patient and physician was favorable toward lozenge. Incidences of adverse events were similar in both the groups. Conclusions: The study suggests that lidocaine lozenges are an easier way of applying local oropharyngeal anesthesia, produces better suppression of gag reflex and makes the procedure easier when compared with lidocaine spray.

  20. Testicular biopsy in psittacine birds (Psittaciformes): impact of endoscopy and biopsy on health, testicular morphology, and sperm parameters.

    Science.gov (United States)

    Hänse, Maria; Krautwald-Junghanns, Maria-Elisabeth; Reitemeier, Susanne; Einspanier, Almuth; Schmidt, Volker

    2013-12-01

    Histologic examination of a testicular biopsy sample may be required to evaluate the reproductive status of male psittacine birds. The purpose of this study was to evaluate the viability of testicular sampling from live birds by assessing the impact on the birds' health, testicular integrity, and sperm quality. Testicular biopsy samples were obtained by endoscopy 4 times during 12 months from 9 cockatiels (Nymphicus hollandicus) and 7 rose-ringed parakeets (Psittacula krameri). Only 2 of 16 birds showed testicular cicatrization or divided testicular tissue after a single endoscopy. Further complications, such as damage to the air sacs or bleeding, predominantly occurred in subsequent endoscopies. In both species, endoscopy and testicular biopsy caused only minor or transient effects on sperm production and sperm quality. These results support that a single testicular biopsy is a viable method for evaluating the reproductive status of male psittacine birds.

  1. Pilot randomized crossover study comparing the efficacy of transnasal disposable endosheath with standard endoscopy to detect Barrett's esophagus.

    Science.gov (United States)

    Shariff, Mohammed K; Varghese, Sibu; O'Donovan, Maria; Abdullahi, Zarah; Liu, Xinxue; Fitzgerald, Rebecca C; di Pietro, Massimiliano

    2016-02-01

    The transnasal endosheath endoscope is a new disposable technology with potential applicability to the primary care setting. The aim of this study was to evaluate the efficacy of transnasal endosheath endoscopy (TEE) for the detection of Barrett's esophagus, by comparing the diagnostic accuracy of TEE with that of standard endoscopy. This was a prospective, randomized, crossover study performed in a single tertiary referral center. Consecutive patients undergoing surveillance for Barrett's esophagus or referred for diagnostic assessment were recruited. All patients were randomized to undergo TEE followed by standard endoscopy or the reverse. Endoscopy experiences and patient preferences were evaluated using a questionnaire. Endoscopic and histologic diagnosis of Barrett's esophagus, and optical image quality of both endoscopic procedures, were compared. A total of 21 of 25 patients completed the study. TEE had sensitivity and specificity of 100 % for an endoscopic diagnosis of Barrett's esophagus, and of 66.7 % and 100 %, respectively, for the histologic diagnosis of Barrett's esophagus. The mean optical quality of standard endoscopy was significantly better than that of TEE (7.11 ± 0.42 vs. 4.06 ± 0.27; P evaluation in primary care as an initial diagnostic tool. © Georg Thieme Verlag KG Stuttgart · New York.

  2. Design and Implementation of High-Performance GIS Dynamic Objects Rendering Engine

    Science.gov (United States)

    Zhong, Y.; Wang, S.; Li, R.; Yun, W.; Song, G.

    2017-12-01

    Spatio-temporal dynamic visualization is more vivid than static visualization. It important to use dynamic visualization techniques to reveal the variation process and trend vividly and comprehensively for the geographical phenomenon. To deal with challenges caused by dynamic visualization of both 2D and 3D spatial dynamic targets, especially for different spatial data types require high-performance GIS dynamic objects rendering engine. The main approach for improving the rendering engine with vast dynamic targets relies on key technologies of high-performance GIS, including memory computing, parallel computing, GPU computing and high-performance algorisms. In this study, high-performance GIS dynamic objects rendering engine is designed and implemented for solving the problem based on hybrid accelerative techniques. The high-performance GIS rendering engine contains GPU computing, OpenGL technology, and high-performance algorism with the advantage of 64-bit memory computing. It processes 2D, 3D dynamic target data efficiently and runs smoothly with vast dynamic target data. The prototype system of high-performance GIS dynamic objects rendering engine is developed based SuperMap GIS iObjects. The experiments are designed for large-scale spatial data visualization, the results showed that the high-performance GIS dynamic objects rendering engine have the advantage of high performance. Rendering two-dimensional and three-dimensional dynamic objects achieve 20 times faster on GPU than on CPU.

  3. Alternative Agents to Prevent Fogging in Head and Neck Endoscopy

    Directory of Open Access Journals (Sweden)

    Patorn Piromchai

    2011-01-01

    Full Text Available Background The essential factor for diagnosis and treatment of diseases in head and neck endoscopy is the visibility of the image. An anti-fogging agent can reduce this problem by minimizing surface tension to prevent the condensation of water in the form of small droplets on a surface. There is no report on the use of hibiscrub ® or baby shampoo to reduce fogging in the literature. The objective of this study was to compare the efficacy between commercial anti-fogging agent, hibiscrub ® and baby shampoo to reduce fogging for the use in head and neck endoscopy. Methods The study was conducted at the Department of Otorhinolaryngology, Faculty of Medicine, Khon Kaen University in August 2010. Commercial anti-fogging agent, baby shampoo and hibiscrub ® were applied on rigid endoscope lens before putting them into a mist generator. The images were taken at baseline, 15 seconds, 30 seconds and 1 minute. The images' identifiers were removed before they were sent to two evaluators. A visual analogue scale (VAS was used to rate the image quality from 0 to 10. Results The difference in mean VAS score between anti-fogging agent, baby shampoo and hibiscrub ® versus no agent were 5.46, 4.45 and 2.1 respectively. The commercial anti-fogging agent and baby shampoo had most protective benefit and performed significantly better than no agent ( P < 0.05. Conclusions Baby shampoo is an effective agent to prevent fogging during head and neck endoscopy and compares favourably with commercial anti-fogging agent.

  4. Blood detection in wireless capsule endoscopy using expectation maximization clustering

    Science.gov (United States)

    Hwang, Sae; Oh, JungHwan; Cox, Jay; Tang, Shou Jiang; Tibbals, Harry F.

    2006-03-01

    Wireless Capsule Endoscopy (WCE) is a relatively new technology (FDA approved in 2002) allowing doctors to view most of the small intestine. Other endoscopies such as colonoscopy, upper gastrointestinal endoscopy, push enteroscopy, and intraoperative enteroscopy could be used to visualize up to the stomach, duodenum, colon, and terminal ileum, but there existed no method to view most of the small intestine without surgery. With the miniaturization of wireless and camera technologies came the ability to view the entire gestational track with little effort. A tiny disposable video capsule is swallowed, transmitting two images per second to a small data receiver worn by the patient on a belt. During an approximately 8-hour course, over 55,000 images are recorded to a worn device and then downloaded to a computer for later examination. Typically, a medical clinician spends more than two hours to analyze a WCE video. Research has been attempted to automatically find abnormal regions (especially bleeding) to reduce the time needed to analyze the videos. The manufacturers also provide the software tool to detect the bleeding called Suspected Blood Indicator (SBI), but its accuracy is not high enough to replace human examination. It was reported that the sensitivity and the specificity of SBI were about 72% and 85%, respectively. To address this problem, we propose a technique to detect the bleeding regions automatically utilizing the Expectation Maximization (EM) clustering algorithm. Our experimental results indicate that the proposed bleeding detection method achieves 92% and 98% of sensitivity and specificity, respectively.

  5. Planned second look endoscopy in patients with bleeding duodenal or gastric ulcers

    DEFF Research Database (Denmark)

    Trap, R; Skarbye, M; Rosenberg, J

    2000-01-01

    1998. Planned second look endoscopy and repeated sclerotherapy were standard care. The effects were evaluated by comparing the expected number of rebleeders with actual rebleeders. At the same time we assessed predicting factors for rebleeding. RESULTS: Fifteen of the admitted seventy patients were...... found to rebleed after initial sclerotherapy. The overall success rate of endoscopic therapy was 63/70 patients (90%). Six patients (9%) had to undergo surgery to obtain haemostasis, and one patient died suddenly after the second endoscopic sclerotherapy. Perforation was seen in two patients (3...... of the present study suggests a beneficial effect on rebleeding rate of patients treated with planned second look endoscopy. Future controlled trails should verify this hypothesis....

  6. Haptic rendering for simulation of fine manipulation

    CERN Document Server

    Wang, Dangxiao; Zhang, Yuru

    2014-01-01

    This book introduces the latest progress in six degrees of freedom (6-DoF) haptic rendering with the focus on a new approach for simulating force/torque feedback in performing tasks that require dexterous manipulation skills. One of the major challenges in 6-DoF haptic rendering is to resolve the conflict between high speed and high fidelity requirements, especially in simulating a tool interacting with both rigid and deformable objects in a narrow space and with fine features. The book presents a configuration-based optimization approach to tackle this challenge. Addressing a key issue in man

  7. Competence and quality assessment: the future of training in GI endoscopy

    NARCIS (Netherlands)

    V.E. Ekkelenkamp (Vivian)

    2014-01-01

    markdownabstract__Abstract__ __Introduction__: Training procedural skills in gastrointestinal endoscopy once focused on threshold numbers. However, as threshold numbers poorly reflect individual competence, the focus gradually shifts towards a more individual approach. Tools to assess and

  8. Historical analysis of experience with small bowel capsule endoscopy in a spanish tertiary hospital.

    Science.gov (United States)

    Egea Valenzuela, Juan; Carrilero Zaragoza, Gabriel; Iglesias Jorquera, Elena; Tomás Pujante, Paula; Alberca de Las Parras, Fernando; Carballo Álvarez, Fernando

    2017-02-01

    Capsule endoscopy was approved by the FDA in 2001. Gastrointestinal bleeding and inflammatory bowel disease are the main indications. It has been available in our hospital since 2004. We retrospectively analysed data from patients who underwent small bowel capsule endoscopy in our hospital from October 2004 to April 2015. Indications were divided into: Obscure gastrointestinal bleeding (occult and overt), inflammatory bowel disease, and other indications. Findings were divided into: Vascular lesions, inflammatory lesions, other lesions, normal studies, and inconclusive studies. A total of 1027 out of 1291 small bowel studies were included. Mean patient age was 56.45 years; 471 were men and 556 women. The most common lesion observed was angiectasia, as an isolated finding or associated with other lesions. Findings were significant in up to 80% of studies when the indication was gastrointestinal bleeding, but in only 50% of studies in inflammatory bowel disease. Diagnostic yield was low in the group «other indications». No major complications were reported. Small bowel capsule endoscopy has high diagnostic yield in patients with gastrointestinal bleeding, but yield is lower in patients with inflammatory bowel disease. Our experience shows that capsule endoscopy is a safe and useful tool for the diagnosis of small bowel disease. The diagnostic yield of the technique in inflammatory bowel disease must be improved. Copyright © 2016 Elsevier España, S.L.U., AEEH y AEG. All rights reserved.

  9. GRAPHICS-IMAGE MIXED METHOD FOR LARGE-SCALE BUILDINGS RENDERING

    Directory of Open Access Journals (Sweden)

    Y. Zhou

    2018-05-01

    Full Text Available Urban 3D model data is huge and unstructured, LOD and Out-of-core algorithm are usually used to reduce the amount of data that drawn in each frame to improve the rendering efficiency. When the scene is large enough, even the complex optimization algorithm is difficult to achieve better results. Based on the traditional study, a novel idea was developed. We propose a graphics and image mixed method for large-scale buildings rendering. Firstly, the view field is divided into several regions, the graphics-image mixed method used to render the scene on both screen and FBO, then blending the FBO with scree. The algorithm is tested on the huge CityGML model data in the urban areas of New York which contained 188195 public building models, and compared with the Cesium platform. The experiment result shows the system was running smoothly. The experimental results confirm that the algorithm can achieve more massive building scene roaming under the same hardware conditions, and can rendering the scene without vision loss.

  10. Enhancement method for rendered images of home decoration based on SLIC superpixels

    Science.gov (United States)

    Dai, Yutong; Jiang, Xiaotong

    2018-04-01

    Rendering technology has been widely used in the home decoration industry in recent years for images of home decoration design. However, due to the fact that rendered images of home decoration design rely heavily on the parameters of renderer and the lights of scenes, most rendered images in this industry require further optimization afterwards. To reduce workload and enhance rendered images automatically, an algorithm utilizing neural networks is proposed in this manuscript. In addition, considering few extreme conditions such as strong sunlight and lights, SLIC superpixels based segmentation is used to choose out these bright areas of an image and enhance them independently. Finally, these chosen areas are merged with the entire image. Experimental results show that the proposed method effectively enhances the rendered images when compared with some existing algorithms. Besides, the proposed strategy is proven to be adaptable especially to those images with obvious bright parts.

  11. European Society of Gastrointestinal Endoscopy (ESGE): recommendations (2009) on clinical use of video capsule endoscopy to investigate small-bowel, esophageal and colonic diseases.

    Science.gov (United States)

    Ladas, S D; Triantafyllou, K; Spada, C; Riccioni, M E; Rey, J-F; Niv, Y; Delvaux, M; de Franchis, R; Costamagna, G

    2010-03-01

    These recommendations on video capsule endoscopy, an emerging technology with an impact on the practice of endoscopy, were developed by the European Society of Gastrointestinal Endoscopy (ESGE) Guidelines Committee. The first draft of each section was prepared by one or two members of the writing team, who were selected as experts on the content of that section on the basis of their published work. They used evidence-based methodology, performing MEDLINE and PubMed literature searches to identify relevant clinical studies. Abstracts from scientific meetings were included only if there was no published full paper on a particular topic. If there was disagreement, the first author of the Guideline made the final decision. Recommendations were graded according to the strength of the supporting evidence. The draft guideline was critically reviewed by all authors and submitted to the ESGE councillors for their critical review before approval of the final document. The ESGE Guidelines Committee acknowledges that this document is based on a critical review of the data available at the time of preparation and that further studies may be needed to clarify some aspects. Moreover, this Guideline may be revised as necessary to account for changes in technology, new data, or other aspects of clinical practice. This document should be regarded as supplying recommendations only to gastroenterologists in providing care to their patients. It is not a set of rules and should not be construed as establishing a legal standard of care, or as encouraging, advocating, requiring, or discouraging any particular treatment. These recommendations must be interpreted according to the clinician's knowledge, expertise, and clinical judgment in the management of individual patients and, if necessary, a course of action that varies from recommendations must be undertaken. Georg Thieme Verlag KG Stuttgart. New York.

  12. Quantitative analysis of patients with celiac disease by video capsule endoscopy: A deep learning method.

    Science.gov (United States)

    Zhou, Teng; Han, Guoqiang; Li, Bing Nan; Lin, Zhizhe; Ciaccio, Edward J; Green, Peter H; Qin, Jing

    2017-06-01

    Celiac disease is one of the most common diseases in the world. Capsule endoscopy is an alternative way to visualize the entire small intestine without invasiveness to the patient. It is useful to characterize celiac disease, but hours are need to manually analyze the retrospective data of a single patient. Computer-aided quantitative analysis by a deep learning method helps in alleviating the workload during analysis of the retrospective videos. Capsule endoscopy clips from 6 celiac disease patients and 5 controls were preprocessed for training. The frames with a large field of opaque extraluminal fluid or air bubbles were removed automatically by using a pre-selection algorithm. Then the frames were cropped and the intensity was corrected prior to frame rotation in the proposed new method. The GoogLeNet is trained with these frames. Then, the clips of capsule endoscopy from 5 additional celiac disease patients and 5 additional control patients are used for testing. The trained GoogLeNet was able to distinguish the frames from capsule endoscopy clips of celiac disease patients vs controls. Quantitative measurement with evaluation of the confidence was developed to assess the severity level of pathology in the subjects. Relying on the evaluation confidence, the GoogLeNet achieved 100% sensitivity and specificity for the testing set. The t-test confirmed the evaluation confidence is significant to distinguish celiac disease patients from controls. Furthermore, it is found that the evaluation confidence may also relate to the severity level of small bowel mucosal lesions. A deep convolutional neural network was established for quantitative measurement of the existence and degree of pathology throughout the small intestine, which may improve computer-aided clinical techniques to assess mucosal atrophy and other etiologies in real-time with videocapsule endoscopy. Copyright © 2017 Elsevier Ltd. All rights reserved.

  13. View compensated compression of volume rendered images for remote visualization.

    Science.gov (United States)

    Lalgudi, Hariharan G; Marcellin, Michael W; Bilgin, Ali; Oh, Han; Nadar, Mariappan S

    2009-07-01

    Remote visualization of volumetric images has gained importance over the past few years in medical and industrial applications. Volume visualization is a computationally intensive process, often requiring hardware acceleration to achieve a real time viewing experience. One remote visualization model that can accomplish this would transmit rendered images from a server, based on viewpoint requests from a client. For constrained server-client bandwidth, an efficient compression scheme is vital for transmitting high quality rendered images. In this paper, we present a new view compensation scheme that utilizes the geometric relationship between viewpoints to exploit the correlation between successive rendered images. The proposed method obviates motion estimation between rendered images, enabling significant reduction to the complexity of a compressor. Additionally, the view compensation scheme, in conjunction with JPEG2000 performs better than AVC, the state of the art video compression standard.

  14. Real-time volume rendering of digital medical images on an iOS device

    Science.gov (United States)

    Noon, Christian; Holub, Joseph; Winer, Eliot

    2013-03-01

    Performing high quality 3D visualizations on mobile devices, while tantalizingly close in many areas, is still a quite difficult task. This is especially true for 3D volume rendering of digital medical images. Allowing this would empower medical personnel a powerful tool to diagnose and treat patients and train the next generation of physicians. This research focuses on performing real time volume rendering of digital medical images on iOS devices using custom developed GPU shaders for orthogonal texture slicing. An interactive volume renderer was designed and developed with several new features including dynamic modification of render resolutions, an incremental render loop, a shader-based clipping algorithm to support OpenGL ES 2.0, and an internal backface culling algorithm for properly sorting rendered geometry with alpha blending. The application was developed using several application programming interfaces (APIs) such as OpenSceneGraph (OSG) as the primary graphics renderer coupled with iOS Cocoa Touch for user interaction, and DCMTK for DICOM I/O. The developed application rendered volume datasets over 450 slices up to 50-60 frames per second, depending on the specific model of the iOS device. All rendering is done locally on the device so no Internet connection is required.

  15. Glossopharyngeal Nerve Block versus Lidocaine Spray to Improve Tolerance in Upper Gastrointestinal Endoscopy

    Directory of Open Access Journals (Sweden)

    Moisés Ortega Ramírez

    2013-01-01

    Full Text Available Aim of the Study. To compare the effect of glossopharyngeal nerve block with topical anesthesia on the tolerance of patients to upper gastrointestinal endoscopy. Methods. We performed a clinical trial in one hundred patients undergoing upper gastrointestinal endoscopy. Subjects were randomly assigned to one of the following two groups: (1 treatment with bilateral glossopharyngeal nerve block (GFNB and intravenous midazolam or (2 treatment with topical anesthetic (TASS and intravenous midazolam. We evaluated sedation, tolerance to the procedure, hemodynamic stability, and adverse symptoms. Results. We studied 46 men and 54 women, from 17 to 78 years of age. The procedure was reported without discomfort in 48 patients (88% in the GFNB group and 32 (64% in the TAAS group; 6 patients (12% in GFNB group and 18 (36% in TAAS group reported the procedure as little discomfort (χ2=3.95, P=0.04. There was no difference in frequency of nausea (4% in both groups and retching, 4% versus 8% for GFNB and TASS group, respectively (P=0.55. Conclusions. The use of glossopharyngeal nerve block provides greater comfort and tolerance to the patient undergoing upper gastrointestinal endoscopy. It also reduces the need for sedation.

  16. Wireless capsule endoscopy of the small bowel: development, testing, and first human trials

    Science.gov (United States)

    Swain, Paul; Iddan, Gavriel J.; Meron, Gavriel; Glukhovsky, Arkady

    2001-01-01

    Small bowel endoscopy with existing endoscopes is limited by problems of discomfort and the technical difficulty of advancing far into the small-bowel. Our aim has been to develop and test wireless capsule endoscopy. Wireless endoscopes, in the form of capsules (11 x 33 mm), were constructed by Given Imaging. These were powered by silver oxide batteries and each contained a CMOS imaging chip and miniature processor, white light emitting diodes (LEDs), a short focal length lens, and a miniature transmitter and antenna. Two video frames per second were transmitted, using radio-frequency (approx. 410 MHz), to an array of aerials attached to the body. The array of aerials can also be used to calculate the position of the capsule in the body. The images were stored on a portable recorder carried on a belt and subsequently downloaded for analysis. The batteries allow more than 5 hours of recording, although the capsule generally passes through the whole small bowel in under two hours. Clear video images of the human bowel were recorded from the pylorus to the caecum. Wireless endoscopy, for the first time, allows painless optical imaging of the whole of the small bowel.

  17. Use of endoscopy in diagnosis and management of patients with dysphagia in an African setting.

    Science.gov (United States)

    Mudawi, H M Y; Mahmoud, A O A; El Tahir, M A; Suliman, S H; Ibrahim, S Z

    2010-04-01

    The objectives of this study were to define the utility of esophagogastroduodenoscopy in the diagnosis and management of patients presenting with dysphagia and to determine the relative incidence of the various causes of dysphagia in Sudan. This is a prospective, cross-sectional, descriptive, hospital-based study carried out at the endoscopy unit of Soba University Hospital, Khartoum, Sudan. All patients complaining of dysphagia underwent upper gastrointestinal endoscopy with therapeutic intervention when necessary. A total of 114 patients were enrolled in the study, with a mean age of 47 years SD +/- 19 and a male to female ratio of 1 : 1.04. A benign condition was diagnosed in 56% of the cases; this included esophageal strictures in 21% of the cases and achalasia in 14%. Malignant causes were mainly due to esophageal cancer (40.4%) and cancer of the stomach cardia (3.5%). Therapeutic intervention was attempted in 83% of the cases. Risk factors predictive of a malignant etiology were age over 40 years (P dysphagia lasting between 1 month and 1 year (P endoscopy in our African setting is an accurate and useful investigation in the diagnosis and management of patients presenting with dysphagia. Patients over the age of 40 years presenting with dysphagia and weight loss are more likely to have a neoplastic disease and should be referred for urgent endoscopy.

  18. Disparities in the receipt of fecal occult blood test versus endoscopy among Filipino American immigrants.

    Science.gov (United States)

    Maxwell, Annette E; Danao, Leda L; Crespi, Catherine M; Antonio, Cynthia; Garcia, Gabriel M; Bastani, Roshan

    2008-08-01

    This report examines disparities associated with the type of colorectal screening test, fecal occult blood test versus endoscopy, within a particular racial/ethnic group, Filipino American immigrants. Between July 2005 and October 2006, Filipino Americans aged 50 to 75 years from 31 community organizations in Los Angeles completed a 15-minute survey in English (65%) or Filipino (35%). Of the 487 respondents included in this analysis, 257 (53%) had never received any type of colorectal cancer screening. Among the 230 subjects who had ever received a routine screening test, 78 had fecal occult blood test only (16% of the total sample), and 152 had endoscopy with or without fecal occult blood test (31% of the total sample). After controlling for access to care and key demographic variables in a multivariate analysis, only two characteristics distinguished between respondents who had fecal occult blood test only versus those who had endoscopy: acculturation, assessed by percent lifetime in the United States and language of interview, and income. Our data suggest a two-tier system, fecal occult blood test for less acculturated Filipino Americans with lower income versus endoscopy for Filipino immigrants with higher levels of acculturation and income. The disparity persists after adjusting for access to care. Instead of treating minority groups as monolithic, differences within groups need to be examined so that interventions can be appropriately targeted.

  19. Anesthesiology training using 3D imaging and virtual reality

    Science.gov (United States)

    Blezek, Daniel J.; Robb, Richard A.; Camp, Jon J.; Nauss, Lee A.

    1996-04-01

    Current training for regional nerve block procedures by anesthesiology residents requires expert supervision and the use of cadavers; both of which are relatively expensive commodities in today's cost-conscious medical environment. We are developing methods to augment and eventually replace these training procedures with real-time and realistic computer visualizations and manipulations of the anatomical structures involved in anesthesiology procedures, such as nerve plexus injections (e.g., celiac blocks). The initial work is focused on visualizations: both static images and rotational renderings. From the initial results, a coherent paradigm for virtual patient and scene representation will be developed.

  20. Virtual Reality System with Integrated Sound Field Simulation and Reproduction

    Directory of Open Access Journals (Sweden)

    Ingo Assenmacher

    2007-01-01

    Full Text Available A real-time audio rendering system is introduced which combines a full room-specific simulation, dynamic crosstalk cancellation, and multitrack binaural synthesis for virtual acoustical imaging. The system is applicable for any room shape (normal, long, flat, coupled, independent of the a priori assumption of a diffuse sound field. This provides the possibility of simulating indoor or outdoor spatially distributed, freely movable sources and a moving listener in virtual environments. In addition to that, near-to-head sources can be simulated by using measured near-field HRTFs. The reproduction component consists of a headphone-free reproduction by dynamic crosstalk cancellation. The focus of the project is mainly on the integration and interaction of all involved subsystems. It is demonstrated that the system is capable of real-time room simulation and reproduction and, thus, can be used as a reliable platform for further research on VR applications.

  1. Method and system for rendering and interacting with an adaptable computing environment

    Science.gov (United States)

    Osbourn, Gordon Cecil [Albuquerque, NM; Bouchard, Ann Marie [Albuquerque, NM

    2012-06-12

    An adaptable computing environment is implemented with software entities termed "s-machines", which self-assemble into hierarchical data structures capable of rendering and interacting with the computing environment. A hierarchical data structure includes a first hierarchical s-machine bound to a second hierarchical s-machine. The first hierarchical s-machine is associated with a first layer of a rendering region on a display screen and the second hierarchical s-machine is associated with a second layer of the rendering region overlaying at least a portion of the first layer. A screen element s-machine is linked to the first hierarchical s-machine. The screen element s-machine manages data associated with a screen element rendered to the display screen within the rendering region at the first layer.

  2. Integral image rendering procedure for aberration correction and size measurement.

    Science.gov (United States)

    Sommer, Holger; Ihrig, Andreas; Ebenau, Melanie; Flühs, Dirk; Spaan, Bernhard; Eichmann, Marion

    2014-05-20

    The challenge in rendering integral images is to use as much information preserved by the light field as possible to reconstruct a captured scene in a three-dimensional way. We propose a rendering algorithm based on the projection of rays through a detailed simulation of the optical path, considering all the physical properties and locations of the optical elements. The rendered images contain information about the correct size of imaged objects without the need to calibrate the imaging device. Additionally, aberrations of the optical system may be corrected, depending on the setup of the integral imaging device. We show simulation data that illustrates the aberration correction ability and experimental data from our plenoptic camera, which illustrates the capability of our proposed algorithm to measure size and distance. We believe this rendering procedure will be useful in the future for three-dimensional ophthalmic imaging of the human retina.

  3. Development and implementation of a comprehensive quality assurance program at a community endoscopy facility.

    Science.gov (United States)

    Hilsden, Robert Jay; Rostom, Alaa; Dubé, Catherine; Pontifex, Darlene; McGregor, S Elizabeth; Bridges, Ronald J

    2011-10-01

    Quality assurance (QA) is a process that includes the systematic evaluation of a service, institution of improvements and ongoing evaluation to ensure that effective changes were made. QA is a fundamental component of any organized colorectal cancer screening program. However, it should play an equally important role in opportunistic screening. Establishing the processes and procedures for a comprehensive QA program can be a daunting proposition for an endoscopy unit. The present article describes the steps taken to establish a QA program at the Forzani & MacPhail Colon Cancer Screening Centre (Calgary, Alberta) - a colorectal cancer screening centre and nonhospital endoscopy unit that is dedicated to providing colorectal cancer screening-related colonoscopies. Lessons drawn from the authors' experience may help others develop their own initiatives. The Global Rating Scale, a quality assessment and improvement tool developed for the gastrointestinal endoscopy services of the United Kingdom's National Health Service, was used as the framework to develop the QA program. QA activities include monitoring the patient experience through surveys, creating endoscopist report cards on colonoscopy performance, tracking and evaluating adverse events and monitoring wait times.

  4. Opinion of gastroenterologists towards quality assurance in endoscopy.

    Science.gov (United States)

    de Jonge, Vincent; Kuipers, Ernst J; van Leerdam, Monique E

    2011-03-01

    Quality assurance has become an important issue. Many societies are adopting quality assurance programs in order to monitor and improve quality of care. To assess the opinion of gastroenterologists towards quality assurance on the endoscopy department. A survey was sent to all gastroenterologists (n=319) in the Netherlands. It assessed their opinion on a quality assurance program for endoscopy units, including its design, logistics, and content. 200 gastroenterologists (63%) completed the questionnaire. 95% had a positive opinion towards quality assurance and 67% supposed an increase in quality. 28% assumed a negative impact on the time available for patient contact by introducing a quality assurance program and 35% that the capacity would decrease. A negative attitude towards disclosure of results to insurance companies (23%) and media (53%) was reported. Female gastroenterologists were less positive to share the results with other stakeholders (pquality measurements were assessment of complications (97%), standardised reporting (96%), and adequate patient information (95%). Gastroenterologists have a positive attitude towards quality assurance. However, concerns do exist about time investment and disclosure of results to others. Information provision and procedure characteristics were considered the most important aspects of quality assurance. Copyright © 2010 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  5. Efficacy and safety of flumazenil injection for the reversal of midazolam sedation after elective outpatient endoscopy.

    Science.gov (United States)

    Lee, Sang Pyo; Sung, In-Kyung; Kim, Jeong Hwan; Lee, Sun-Young; Park, Hyung Seok; Shim, Chan Sup

    2018-02-01

    Midazolam sedation during elective endoscopy is widely performed and flumazenil is frequently administered after endoscopy to reverse sedation in clinical practice. This study aimed to investigate the safety and efficacy of flumazenil injections after elective endoscopy under midazolam sedation. Participants who underwent an upper endoscopy under midazolam sedation were randomly divided into two groups. In group I, flumazenil was administered i.v. 10 min after the patient's transfer to the recovery room, and no antidote was injected in group II. The time of stay in the recovery room and adverse events were reviewed through the nursing records. We asked the patients about their pain and degree of satisfaction according to a visual analogue scale (VAS), their memory of the procedure, mental status and the presence of uncomfortable symptoms on the day of the procedure and the day afterwards. The length of stay in recovery was significantly shorter in group I than in group II. No significant differences were found in the number of patients with pain (VAS ≥1), adverse events and discomfort between the two groups. Additionally, there were no differences in the patients' memory of the procedure, satisfaction with sedation, willingness to repeat the endoscopy and mental status. The time in the recovery room after flumazenil administration was significantly shortened, and the use of the drug did not increase the risk of adverse events or discomfort. The use of flumazenil for reversing midazolam sedation seems to be safe and effective. © 2018 Chinese Medical Association Shanghai Branch, Chinese Society of Gastroenterology, Renji Hospital Affiliated to Shanghai Jiaotong University School of Medicine and John Wiley & Sons Australia, Ltd.

  6. Light Field Rendering for Head Mounted Displays using Pixel Reprojection

    DEFF Research Database (Denmark)

    Hansen, Anne Juhler; Klein, Jákup; Kraus, Martin

    2017-01-01

    Light field displays have advantages over traditional stereoscopic head mounted displays, for example, because they can overcome the vergence-accommodation conflict. However, rendering light fields can be a heavy task for computers due to the number of images that have to be rendered. Since much ...

  7. Light Field Rendering for Head Mounted Displays using Pixel Reprojection

    DEFF Research Database (Denmark)

    Hansen, Anne Juhler; Klein, Jákup; Kraus, Martin

    2017-01-01

    of the information of the different images is redundant, we use pixel reprojection from the corner cameras to compute the remaining images in the light field. We compare the reprojected images with directly rendered images in a user test. In most cases, the users were unable to distinguish the images. In extreme...... cases, the reprojection approach is not capable of creating the light field. We conclude that pixel reprojection is a feasible method for rendering light fields as far as quality of perspective and diffuse shading is concerned, but render time needs to be reduced to make the method practical....

  8. Microscopic polyangiitis complicated with ileal involvement detected by double-balloon endoscopy: a case report.

    Science.gov (United States)

    Fukushima, Masashi; Inoue, Satoko; Ono, Yuichiro; Tamaki, Yoshitaka; Yoshimura, Hajime; Imai, Yukihiro; Inokuma, Tetsuro

    2013-03-02

    Microscopic polyangiitis is characterized by pauci-immune, necrotizing small-vessel vasculitis and an anti-neutrophil cytoplasmic antibody-associated vasculitis. Although gastrointestinal involvement in microscopic polyangiitis is not rare, endoscopic observation of it is extremely rare. To the best of our knowledge, this is the first case report of small intestinal involvement in microscopic polyangiitis detected and followed up by double-balloon endoscopy. A 70-year-old Japanese woman was transferred to our hospital for close examination of suspected small intestinal lymphoma. Retrograde double-balloon endoscopy revealed various forms of ulcers with redness and edema in the ileum. Histological findings suggested ischemic changes. Because mononeuritis multiplex and a fever spike appeared later, vasculitis was suspected. The perinuclear anti-neutrophil cytoplasmic antibody titer was elevated. Nerve biopsy results suggested vasculitis. From these findings, microscopic polyangiitis was diagnosed. It was suggested that microscopic polyangiitis caused the intestinal involvement. Intravenous pulse cyclophosphamide and oral predonisolone were started. After treatment, perinuclear anti-neutrophil cytoplasmic antibodies decreased to the normal range. Retrograde double-balloon endoscopy after treatment showed ulcer scars and no ulcer. The cause of gastrointestinal involvement in microscopic polyangiitis is ischemia due to vasculitis. It is difficult to diagnose small-vessel vasculitis by endoscopic biopsy. Although histological evidence of microscopic polyangiitis is important, the treatment should not be delayed by repeating the biopsy, because such delay can result in adverse sequela.This case report shows that microscopic polyangiitis should be considered as a differential diagnosis when small intestinal changes like those in the present case are observed by endoscopy.

  9. CT colonoscopy: sensibility in 2D/4D CT colonoscopy versus virtual endoscopy. Correlation to conventional colonoscopy

    International Nuclear Information System (INIS)

    Carrascosa, Patricia; Capunay, Carlos; Sanchez, Flavio; Castiglioni, Roberto; Carrascosa, Jorge

    2001-01-01

    Colorectal carcinoma is the second leading cause of death from malignant tumors. Most large bowel malignancies arise from pre-existing adenomas. In individual older than 50 years the prevalence of polyps and cancer increases. Therefore screening is recommended for average risk individuals in this group. Recently a new technique called 'Virtual Colonoscopy' has appeared. The purpose of this study was to compare the diagnosis accuracy of two dimensional CT Colonoscopy (2D CTC) and Virtual Colonoscopy (VC) individually with Conventional Colonoscopy (CC) and to determine improvement of the Sensitivity (S) and Specificity (E) combining both types of evaluation. Ninety patients were studied (47 women and 43 men). CT studies were obtained on a helical CT scanner. The lesions were studied in supine and prone position. All patients had CC done within 10 hours before CTC. The lesions were divided in 3 groups: 1) 9 mm. Each group was divided into 3 subgroups: a) findings in 2D; b) findings in VC; and c) findings combined. Ninety-two lesions were identified on CC and 101 on CTC. There were 9 false positive in all groups. The statistical analysis showed a high S and E in both 2D and VC. The combination of both methods does not increase significantly the diagnosis of CTC but the S reached 100% because the false negative rate was reduced to 0. (author)

  10. Nuclear plant's virtual simulation for on-line radioactive environment monitoring and dose assessment for personnel

    International Nuclear Information System (INIS)

    Mol, Antonio Carlos A.; Jorge, Carlos Alexandre F.; Lapa, Celso Marcelo F.

    2009-01-01

    This paper reports the use of nuclear plant's simulation for online dose rate monitoring and dose assessment for personnel, using virtual reality technology. The platform used for virtual simulation was adapted from a low cost game engine, taking advantage of all its image rendering capabilities, as well as the physics for movement and collision, and networking capabilities for multi-user interactive navigation. A real nuclear plant was virtually modeled and simulated, so that a number of users can navigate simultaneously in this virtual environment in first or third person view, each one receiving visual information about both the radiation dose rate in each actual position, and the radiation dose received. Currently, this research and development activity has been extended to consider also on-line measurements collected from radiation monitors installed in the real plant that feed the simulation platform with dose rate data, through a TCP/IP network. Results are shown and commented, and other improvements are discussed, as the execution of a more detailed dose rate mapping campaign.

  11. The burden of upper gastrointestinal endoscopy in patients with Barrett's esophagus

    NARCIS (Netherlands)

    Kruijshaar, M. E.; Kerkhof, M.; Siersema, P. D.; Steyerberg, E. W.; Homs, M. Y. V.; Essink-Bot, M.-L.

    2006-01-01

    BACKGROUND AND STUDY AIMS: Patients with Barrett's esophagus are recommended to undergo regular surveillance with upper gastrointestinal endoscopy, an invasive procedure that may cause anxiety, pain, and discomfort. We assessed to what extent patients perceived this procedure as burdensome. PATIENTS

  12. An upper gastrointestinal ulcer still bleeding after endoscopy : what comes next?

    NARCIS (Netherlands)

    Craenen, E. M. E.; Hofker, Hendrik; Peters, Frans; Kater, G. M.; Glatman, K. R.; Zijlstra, J. G.

    Introduction: Recurrent bleeding from an upper gastrointestinal ulcer when endoscopy fails is a reason for radiological or surgical treatment, both of which have their advantages and disadvantages. Case: Based on a patient with recurrent gastrointestinal bleeding, we reviewed the available evidence

  13. Architecture for high performance stereoscopic game rendering on Android

    Science.gov (United States)

    Flack, Julien; Sanderson, Hugh; Shetty, Sampath

    2014-03-01

    Stereoscopic gaming is a popular source of content for consumer 3D display systems. There has been a significant shift in the gaming industry towards casual games for mobile devices running on the Android™ Operating System and driven by ARM™ and other low power processors. Such systems are now being integrated directly into the next generation of 3D TVs potentially removing the requirement for an external games console. Although native stereo support has been integrated into some high profile titles on established platforms like Windows PC and PS3 there is a lack of GPU independent 3D support for the emerging Android platform. We describe a framework for enabling stereoscopic 3D gaming on Android for applications on mobile devices, set top boxes and TVs. A core component of the architecture is a 3D game driver, which is integrated into the Android OpenGL™ ES graphics stack to convert existing 2D graphics applications into stereoscopic 3D in real-time. The architecture includes a method of analyzing 2D games and using rule based Artificial Intelligence (AI) to position separate objects in 3D space. We describe an innovative stereo 3D rendering technique to separate the views in the depth domain and render directly into the display buffer. The advantages of the stereo renderer are demonstrated by characterizing the performance in comparison to more traditional render techniques, including depth based image rendering, both in terms of frame rates and impact on battery consumption.

  14. Extreme Simplification and Rendering of Point Sets using Algebraic Multigrid

    NARCIS (Netherlands)

    Reniers, Dennie; Telea, Alexandru

    2005-01-01

    We present a novel approach for extreme simplification of point set models in the context of real-time rendering. Point sets are often rendered using simple point primitives, such as oriented discs. However efficient, simple primitives are less effective in approximating large surface areas. A large

  15. A simplified clinical risk score predicts the need for early endoscopy in non-variceal upper gastrointestinal bleeding.

    Science.gov (United States)

    Tammaro, Leonardo; Buda, Andrea; Di Paolo, Maria Carla; Zullo, Angelo; Hassan, Cesare; Riccio, Elisabetta; Vassallo, Roberto; Caserta, Luigi; Anderloni, Andrea; Natali, Alessandro

    2014-09-01

    Pre-endoscopic triage of patients who require an early upper endoscopy can improve management of patients with non-variceal upper gastrointestinal bleeding. To validate a new simplified clinical score (T-score) to assess the need of an early upper endoscopy in non variceal bleeding patients. Secondary outcomes were re-bleeding rate, 30-day bleeding-related mortality. In this prospective, multicentre study patients with bleeding who underwent upper endoscopy were enrolled. The accuracy for high risk endoscopic stigmata of the T-score was compared with that of the Glasgow Blatchford risk score. Overall, 602 patients underwent early upper endoscopy, and 472 presented with non-variceal bleeding. High risk endoscopic stigmata were detected in 145 (30.7%) cases. T-score sensitivity and specificity for high risk endoscopic stigmata and bleeding-related mortality was 96% and 30%, and 80% and 71%, respectively. No statistically difference in predicting high risk endoscopic stigmata between T-score and Glasgow Blatchford risk score was observed (ROC curve: 0.72 vs. 0.69, p=0.11). The two scores were also similar in predicting re-bleeding (ROC curve: 0.64 vs. 0.63, p=0.4) and 30-day bleeding-related mortality (ROC curve: 0.78 vs. 0.76, p=0.3). The T-score appeared to predict high risk endoscopic stigmata, re-bleeding and mortality with similar accuracy to Glasgow Blatchford risk score. Such a score may be helpful for the prediction of high-risk patients who need a very early therapeutic endoscopy. Copyright © 2014 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  16. Interactive virtual simulation using a 3D computer graphics model for microvascular decompression surgery.

    Science.gov (United States)

    Oishi, Makoto; Fukuda, Masafumi; Hiraishi, Tetsuya; Yajima, Naoki; Sato, Yosuke; Fujii, Yukihiko

    2012-09-01

    The purpose of this paper is to report on the authors' advanced presurgical interactive virtual simulation technique using a 3D computer graphics model for microvascular decompression (MVD) surgery. The authors performed interactive virtual simulation prior to surgery in 26 patients with trigeminal neuralgia or hemifacial spasm. The 3D computer graphics models for interactive virtual simulation were composed of the brainstem, cerebellum, cranial nerves, vessels, and skull individually created by the image analysis, including segmentation, surface rendering, and data fusion for data collected by 3-T MRI and 64-row multidetector CT systems. Interactive virtual simulation was performed by employing novel computer-aided design software with manipulation of a haptic device to imitate the surgical procedures of bone drilling and retraction of the cerebellum. The findings were compared with intraoperative findings. In all patients, interactive virtual simulation provided detailed and realistic surgical perspectives, of sufficient quality, representing the lateral suboccipital route. The causes of trigeminal neuralgia or hemifacial spasm determined by observing 3D computer graphics models were concordant with those identified intraoperatively in 25 (96%) of 26 patients, which was a significantly higher rate than the 73% concordance rate (concordance in 19 of 26 patients) obtained by review of 2D images only (p computer graphics model provided a realistic environment for performing virtual simulations prior to MVD surgery and enabled us to ascertain complex microsurgical anatomy.

  17. A software system for evaluation and training of spatial reasoning and neuroanatomical knowledge in a virtual environment.

    Science.gov (United States)

    Armstrong, Ryan; de Ribaupierre, Sandrine; Eagleson, Roy

    2014-04-01

    This paper describes the design and development of a software tool for the evaluation and training of surgical residents using an interactive, immersive, virtual environment. Our objective was to develop a tool to evaluate user spatial reasoning skills and knowledge in a neuroanatomical context, as well as to augment their performance through interactivity. In the visualization, manually segmented anatomical surface images of MRI scans of the brain were rendered using a stereo display to improve depth cues. A magnetically tracked wand was used as a 3D input device for localization tasks within the brain. The movement of the wand was made to correspond to movement of a spherical cursor within the rendered scene, providing a reference for localization. Users can be tested on their ability to localize structures within the 3D scene, and their ability to place anatomical features at the appropriate locations within the rendering. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  18. Impact of operator fatigue on endoscopy performance: implications for procedure scheduling.

    LENUS (Irish Health Repository)

    Harewood, Gavin C

    2009-08-01

    With increasing volumes of endoscopic procedures, endoscopists\\' workload has had to increase to meet this escalating demand. The aim of this study was to characterize the impact of endoscopist fatigue on quality of endoscopy performance by comparing outcomes based on chronological procedure order.

  19. "Leopard skin sign": the use of narrow-band imaging with magnification endoscopy in celiac disease.

    Science.gov (United States)

    Tchekmedyian, Asadur J; Coronel, Emmanuel; Czul, Frank

    2014-01-01

    Celiac Disease (CD) is an immune reaction to gluten containing foods such as rye, wheat and barley. This condition affects individuals with a genetic predisposition; it targets the small bowel and may cause symptoms including diarrhea, malabsorption, weight loss, abdominal pain and bloating. The diagnosis is made by serologic testing of celiac-specific antibodies and confirmed by histology. Certain endoscopic characteristics, such as scalloping, reduction in the number of folds, mosaic-pattern mucosa or nodular mucosa, are suggestive of CD and can be visualized under white light endoscopy. Due to its low sensitivity, endoscopy alone is not recommended to diagnose CD; however, enhanced visual identification of suspected mucosal abnormalities through the use of new technologies, such as narrow band imaging with magnification (NBI-ME), could assist in targeting biopsies and thereby increasing the sensitivity of endoscopy. This is a case series of seven patients with serologic and histologic diagnoses of CD who underwent upper endoscopies with NBI-ME imaging technology as part of their CD evaluation. By employing this imaging technology, we could identify patchy atrophy sites in a mosaic pattern, with flattened villi and alteration of the central capillaries of the duodenal mucosa. We refer to this epithelial pattern as "Leopard Skin Sign". Since epithelial lesions are easily seen using NBI-ME, we found it beneficial for identifying and targeting biopsy sites. Larger prospective studies are warranted to confirm our findings.

  20. Flexor Digitorum Accessorius Longus: Importance of Posterior Ankle Endoscopy

    Directory of Open Access Journals (Sweden)

    Jorge Pablo Batista

    2015-01-01

    Full Text Available Endoscopy for the posterior region of the ankle through two portals is becoming more widespread for the treatment of a large number of conditions which used to be treated with open surgery years ago. The tendon of the flexor hallucis longus (FHL travels along an osteofibrous tunnel between the posterolateral and posteromedial tubercles of the talus. Chronic inflammation of this tendon may lead to painful stenosing tenosynovitis. The aim of this report is to describe two cases depicting an accessory tendon which is an anatomical variation of the flexor hallucis longus in patients with posterior friction syndrome due to posterior ankle impingement and associated with a posteromedial osteochondral lesion of the talus. The anatomical variation (FDAL described was a finding during an endoscopy of the posterior region of the ankle, and we have spared it by sectioning the superior flexor retinaculum only. The accessory flexor digitorum longus is an anatomical variation and should be taken into account when performing an arthroscopy of the posterior region of the ankle. We recommend this treatment on this type of injury although we admit this does not make a definite conclusion.

  1. Valeur de l'endoscopie de routine dans le diagnostic de la gastrite ...

    African Journals Online (AJOL)

    Valeur de l'endoscopie de routine dans le diagnostic de la gastrite chronique antrale à Yaoundé. D Noah Noah, F Ankouane Andoulo, SAF Eloumou Bagnaka, PJA Atangana, C Tzeuton, EC Ndjitoyap Ndam ...

  2. SPATIOTEMPORAL VISUALIZATION OF TIME-SERIES SATELLITE-DERIVED CO2 FLUX DATA USING VOLUME RENDERING AND GPU-BASED INTERPOLATION ON A CLOUD-DRIVEN DIGITAL EARTH

    Directory of Open Access Journals (Sweden)

    S. Wu

    2017-10-01

    Full Text Available The ocean carbon cycle has a significant influence on global climate, and is commonly evaluated using time-series satellite-derived CO2 flux data. Location-aware and globe-based visualization is an important technique for analyzing and presenting the evolution of climate change. To achieve realistic simulation of the spatiotemporal dynamics of ocean carbon, a cloud-driven digital earth platform is developed to support the interactive analysis and display of multi-geospatial data, and an original visualization method based on our digital earth is proposed to demonstrate the spatiotemporal variations of carbon sinks and sources using time-series satellite data. Specifically, a volume rendering technique using half-angle slicing and particle system is implemented to dynamically display the released or absorbed CO2 gas. To enable location-aware visualization within the virtual globe, we present a 3D particlemapping algorithm to render particle-slicing textures onto geospace. In addition, a GPU-based interpolation framework using CUDA during real-time rendering is designed to obtain smooth effects in both spatial and temporal dimensions. To demonstrate the capabilities of the proposed method, a series of satellite data is applied to simulate the air-sea carbon cycle in the China Sea. The results show that the suggested strategies provide realistic simulation effects and acceptable interactive performance on the digital earth.

  3. Obscure gastrointestinal bleeding: difficulties in comparing CT enterography and video capsule endoscopy

    International Nuclear Information System (INIS)

    Soyer, Philippe

    2012-01-01

    A paper reports the results of a retrospective study that was designed to evaluate the potential role of video capsule endoscopy (VCE) in elucidating the cause of bleeding in patients with obscure gastrointestinal bleeding (OGIB) for whom CT enterography was negative. The authors highlight the limitations of dual-phase CT enterography for the detection of flat lesions of the small bowel such as ulcers, angiodysplasias or arteriovenous malformations, and confirm the superiority of VCE for the detection of this category of lesions. This commentary discusses some of the issues raised. Key Points circle Video capsule endoscopy surpasses CT enterography in detecting flat small bowel lesions. circle Retrospective VCE and CT enterography findings in obscure bleeding need further evaluation. circle A fair and unbiased comparison of the two investigations is still needed. (orig.)

  4. Color-coded volume rendering for three-dimensional reconstructions of CT data

    International Nuclear Information System (INIS)

    Rieker, O.; Mildenberger, P.; Thelen, M.

    1999-01-01

    Purpose: To evaluate a technique of colored three-dimensional reconstructions without segmentation. Material and methods: Color-coded volume rendered images were reconstructed from the volume data of 25 thoracic, abdominal, musculoskeletal, and vascular helical CT scans using commercial software. The CT volume rendered voxels were encoded with color in the following manner. Opacity, hue, lightness, and chroma were assigned to each of four classes defined by CT number. Color-coded reconstructions were compared to the corresponding grey-scale coded reconstructions. Results: Color-coded volume rendering enabled realistic visualization of pathologic findings when there was sufficient difference in CT density. Segmentation was necessary in some cases to demonstrate small details in a complex volume. Conclusion: Color-coded volume rendering allowed lifelike visualisation of CT volumes without the need of segmentation in most cases. (orig.) [de

  5. Physically-Based Rendering of Particle-Based Fluids with Light Transport Effects

    Science.gov (United States)

    Beddiaf, Ali; Babahenini, Mohamed Chaouki

    2018-03-01

    Recent interactive rendering approaches aim to efficiently produce images. However, time constraints deeply affect their output accuracy and realism (many light phenomena are poorly or not supported at all). To remedy this issue, in this paper, we propose a physically-based fluid rendering approach. First, while state-of-the-art methods focus on isosurface rendering with only two refractions, our proposal (1) considers the fluid as a heterogeneous participating medium with refractive boundaries, and (2) supports both multiple refractions and scattering. Second, the proposed solution is fully particle-based in the sense that no particles transformation into a grid is required. This interesting feature makes it able to handle many particle types (water, bubble, foam, and sand). On top of that, a medium with different fluids (color, phase function, etc.) can also be rendered.

  6. Validation of the National Aeronautics and Space Administration Task Load Index as a tool to evaluate the learning curve for endoscopy training.

    Science.gov (United States)

    Mohamed, Rachid; Raman, Maitreyi; Anderson, John; McLaughlin, Kevin; Rostom, Alaa; Coderre, Sylvain

    2014-03-01

    Although workplace workload assessments exist in different fields, an endoscopy-specific workload assessment tool is lacking. To validate such a workload tool and use it to map the progression of novice trainees in gastroenterology in performing their first endoscopies. The National Aeronautics and Space Administration Task Load Index (NASA-TLX) workload assessment tool was completed by eight novice trainees in gastroenterology and 10 practicing gastroenterologists⁄surgeons. An exploratory factor analysis was performed to construct a streamlined endoscopy-specific task load index, which was subsequently validated. The 'Endoscopy Task Load Index' was used to monitor progression of trainee exertion and self-assessed performance over their first 40 procedures. From the factor analysis of the NASA-TLX, two principal components emerged: a measure of exertion and a measure of self-efficacy. These items became the components of the newly validated Endoscopy Task Load Index. There was a steady decline in self-perceived exertion over the training period, which was more rapid for gastroscopy than colonoscopy. The self-efficacy scores for gastroscopy rapidly increased over the first few procedures, reaching a plateau after this period of time. For colonoscopy, there was a progressive increase in reported self-efficacy over the first three quartiles of procedures, followed by a drop in self-efficacy scores over the final quartile. The present study validated an Endoscopy Task Load Index that can be completed in <1 min. Practical implications of such a tool in endoscopy education include identifying periods of higher perceived exertion among novice endoscopists, facilitating appropriate levels of guidance from trainers.

  7. GyroVR: Simulating Inertia in Virtual Reality using Head Worn Flywheels

    DEFF Research Database (Denmark)

    Gugenheimer, Jan; Wolf, Dennis; Eiríksson, Eyþór Rúnar

    2016-01-01

    We present GyroVR, head worn flywheels designed to render inertia in Virtual Reality (VR. Motions such as flying, diving or floating in outer space generate kinesthetic forces onto our body which impede movement and are currently not represented in VR. We simulate those kinesthetic forces...... by attaching flywheels to the users head, leveraging the gyroscopic effect of resistance when changing the spinning axis of rotation. GyroVR is an ungrounded, wireless and self contained device allowing the user to freely move inside the virtual environment. The generic shape allows to attach it to different...... positions on the users body. We evaluated the impact of GyroVR onto different mounting positions on the head (back and front) in terms of immersion, enjoyment and simulator sickness. Our results show, that attaching GyroVR onto the users head (front of the Head Mounted Display (HMD)) resulted in the highest...

  8. Pulse oximetry and supplemental oxygen during gastrointestinal endoscopy: a critical review

    DEFF Research Database (Denmark)

    Holm, C; Rosenberg, J

    1996-01-01

    A high proportion of the mortality and morbidity associated with endoscopic procedures may be of cardiopulmonary origin. For this reason, the appropriate degree of monitoring and prophylactic measures to be used in the sedated patient undergoing endoscopy has become a topic of discussion during r...

  9. An improved method of continuous LOD based on fractal theory in terrain rendering

    Science.gov (United States)

    Lin, Lan; Li, Lijun

    2007-11-01

    With the improvement of computer graphic hardware capability, the algorithm of 3D terrain rendering is going into the hot topic of real-time visualization. In order to solve conflict between the rendering speed and reality of rendering, this paper gives an improved method of terrain rendering which improves the traditional continuous level of detail technique based on fractal theory. This method proposes that the program needn't to operate the memory repeatedly to obtain different resolution terrain model, instead, obtains the fractal characteristic parameters of different region according to the movement of the viewpoint. Experimental results show that the method guarantees the authenticity of landscape, and increases the real-time 3D terrain rendering speed.

  10. High Fidelity Haptic Rendering

    CERN Document Server

    Otaduy, Miguel A

    2006-01-01

    The human haptic system, among all senses, provides unique and bidirectional communication between humans and their physical environment. Yet, to date, most human-computer interactive systems have focused primarily on the graphical rendering of visual information and, to a lesser extent, on the display of auditory information. Extending the frontier of visual computing, haptic interfaces, or force feedback devices, have the potential to increase the quality of human-computer interaction by accommodating the sense of touch. They provide an attractive augmentation to visual display and enhance t

  11. Upper gastrointestinal endoscopy in patients aged 85 years or more. Results of a feasibility study in a district general hospital.

    NARCIS (Netherlands)

    Kouwen, M.C.A. van; Drenth, J.P.H.; Verhoeven, H.M.; Bos, L.P.; Engels, L.G.

    2003-01-01

    We performed a cross sectional analysis of the feasibility and yield of upper gastrointestinal endoscopy (UGE) in a cohort of patients aged 85 years or more. The study involved 218 patients who underwent diagnostic upper gastrointestinal endoscopy in a district general hospital between 1994 and

  12. Development and Implementation of a Comprehensive Quality Assurance Program at a Community Endoscopy Facility

    Directory of Open Access Journals (Sweden)

    Robert J Hilsden

    2011-01-01

    Full Text Available Quality assurance (QA is a process that includes the systematic evaluation of a service, institution of improvements and ongoing evaluation to ensure that effective changes were made. QA is a fundamental component of any organized colorectal cancer screening program. However, it should play an equally important role in opportunistic screening. Establishing the processes and procedures for a comprehensive QA program can be a daunting proposition for an endoscopy unit. The present article describes the steps taken to establish a QA program at the Forzani & MacPhail Colon Cancer Screening Centre (Calgary, Alberta – a colorectal cancer screening centre and nonhospital endoscopy unit that is dedicated to providing colorectal cancer screening-related colonoscopies. Lessons drawn from the authors’ experience may help others develop their own initiatives. The Global Rating Scale, a quality assessment and improvement tool developed for the gastrointestinal endoscopy services of the United Kingdom’s National Health Service, was used as the framework to develop the QA program. QA activities include monitoring the patient experience through surveys, creating endoscopist report cards on colonoscopy performance, tracking and evaluating adverse events and monitoring wait times.

  13. Non-steroidal anti-inflammatory drug-induced small bowel injuries identified by double-balloon endoscopy

    Science.gov (United States)

    Hayashi, Yoshikazu; Yamamoto, Hironori; Kita, Hiroto; Sunada, Keijiro; Sato, Hiroyuki; Yano, Tomonori; Iwamoto, Michiko; Sekine, Yutaka; Miyata, Tomohiko; Kuno, Akiko; Iwaki, Takaaki; Kawamura, Yoshiyuki; Ajibe, Hironari; Ido, Kenichi; Sugano, Kentaro

    2005-01-01

    AIM: To clarify clinical features of the NSAID-induced small bowel lesions using a new method of endoscopy. METHODS: This is a retrospective study and we analyzed seven patients with small bowel lesions while taking NSAIDs among 61 patients who had undergone double-balloon endoscopy because of gastro-intestinal bleeding or anemia between September 2000 and March 2004, at Jichi Medical School Hospital in Japan. Neither conventional EGD nor colonoscopy revealed any lesions of potential bleeding sources including ulcerations. Double-balloon endoscopy was carried out from oral approach in three patients, from anal approach in three patients, and from both approaches in one patient. RESULTS: Ulcers or erosions were observed in the ileum in six patients and in the jejunum in one patient, respectively. The ulcers were multiple in all the patients with different features from tiny punched out ulcers to deep ulcerations with oozing hemorrhage or scar. All the patients recovered uneventfully and had full resolution of symptoms after suspension of the drug. CONCLUSION: NSAIDs can induce injuries in the small bowel even in patients without any lesions in both the stomach and colon. PMID:16097059

  14. On the design of a real-time volume rendering engine

    NARCIS (Netherlands)

    Smit, Jaap; Wessels, H.L.F.; van der Horst, A.; Bentum, Marinus Jan

    1992-01-01

    An architecture for a Real-Time Volume Rendering Engine (RT-VRE) is given, capable of computing 750 × 750 × 512 samples from a 3D dataset at a rate of 25 images per second. The RT-VRE uses for this purpose 64 dedicated rendering chips, cooperating with 16 RISC-processors. A plane interpolator

  15. On the design of a real-time volume rendering engine

    NARCIS (Netherlands)

    Smit, Jaap; Wessels, H.J.; van der Horst, A.; Bentum, Marinus Jan

    1995-01-01

    An architecture for a Real-Time Volume Rendering Engine (RT-VRE) is given, capable of computing 750 × 750 × 512 samples from a 3D dataset at a rate of 25 images per second. The RT-VRE uses for this purpose 64 dedicated rendering chips, cooperating with 16 RISC-processors. A plane interpolator

  16. A prospective randomized study comparing transnasal and peroral 5-mm ultrathin endoscopy

    Directory of Open Access Journals (Sweden)

    Lian-Feng Lin

    2014-06-01

    Conclusion: PO intubation seems an excellent alternative method when using a 5-mm ultrathin endoscopy because it achieves comparable patient tolerance, acceptance, and satisfaction as TN intubation, takes less time and causes lower intubation failure and epistaxis.

  17. Functionality and Performance Visualization of the Distributed High Quality Volume Renderer (HVR)

    KAUST Repository

    Shaheen, Sara

    2012-07-01

    Volume rendering systems are designed to provide means to enable scientists and a variety of experts to interactively explore volume data through 3D views of the volume. However, volume rendering techniques are computationally intensive tasks. Moreover, parallel distributed volume rendering systems and multi-threading architectures were suggested as natural solutions to provide an acceptable volume rendering performance for very large volume data sizes, such as Electron Microscopy data (EM). This in turn adds another level of complexity when developing and manipulating volume rendering systems. Given that distributed parallel volume rendering systems are among the most complex systems to develop, trace and debug, it is obvious that traditional debugging tools do not provide enough support. As a consequence, there is a great demand to provide tools that are able to facilitate the manipulation of such systems. This can be achieved by utilizing the power of compute graphics in designing visual representations that reflect how the system works and that visualize the current performance state of the system.The work presented is categorized within the field of software Visualization, where Visualization is used to serve visualizing and understanding various software. In this thesis, a number of visual representations that reflect a number of functionality and performance aspects of the distributed HVR, a high quality volume renderer system that uses various techniques to visualize large volume sizes interactively. This work is provided to visualize different stages of the parallel volume rendering pipeline of HVR. This is along with means of performance analysis through a number of flexible and dynamic visualizations that reflect the current state of the system and enables manipulation of them at runtime. Those visualization are aimed to facilitate debugging, understanding and analyzing the distributed HVR.

  18. Traditional microscopy instruction versus process-oriented virtual microscopy instruction: a naturalistic experiment with control group.

    Science.gov (United States)

    Helle, Laura; Nivala, Markus; Kronqvist, Pauliina; Gegenfurtner, Andreas; Björk, Pasi; Säljö, Roger

    2011-03-30

    Virtual microscopy is being introduced in medical education as an approach for learning how to interpret information in microscopic specimens. It is, however, far from evident how to incorporate its use into existing teaching practice. The aim of the study was to explore the consequences of introducing virtual microscopy tasks into an undergraduate pathology course in an attempt to render the instruction more process-oriented. The research questions were: 1) How is virtual microscopy perceived by students? 2) Does work on virtual microscopy tasks contribute to improvement in performance in microscopic pathology in comparison with attending assistant-led demonstrations only? During a one-week period, an experimental group completed three sets of virtual microscopy homework assignments in addition to attending demonstrations. A control group attended the demonstrations only. Performance in microscopic pathology was measured by a pre-test and a post-test. Student perceptions of regular instruction and virtual microscopy were collected one month later by administering the Inventory of Intrinsic Motivation and open-ended questions. The students voiced an appreciation for virtual microscopy for the purposes of the course and for self-study. As for learning gains, the results indicated that learning was speeded up in a subgroup of students consisting of conscientious high achievers. The enriched instruction model may be suited as such for elective courses following the basic course. However, the instructional model needs further development to be suited for basic courses.

  19. Validation of the National Aeronautics and Space Administration Task Load Index as a tool to evaluate-the learning curve for endoscopy training

    Science.gov (United States)

    Mohamed, Rachid; Raman, Maitreyi; Anderson, John; McLaughlin, Kevin; Rostom, Alaa; Coderre, Sylvain

    2014-01-01

    BACKGROUND: Although workplace workload assessments exist in different fields, an endoscopy-specific workload assessment tool is lacking. OBJECTIVE: To validate such a workload tool and use it to map the progression of novice trainees in gastroenterology in performing their first endoscopies. METHODS: The National Aeronautics and Space Administration Task Load Index (NASA-TLX) workload assessment tool was completed by eight novice trainees in gastroenterology and 10 practicing gastroenterologists/surgeons. An exploratory factor analysis was performed to construct a streamlined endoscopy-specific task load index, which was subsequently validated. The ‘Endoscopy Task Load Index’ was used to monitor progression of trainee exertion and self-assessed performance over their first 40 procedures. RESULTS: From the factor analysis of the NASA-TLX, two principal components emerged: a measure of exertion and a measure of self-efficacy. These items became the components of the newly validated Endoscopy Task Load Index. There was a steady decline in self-perceived exertion over the training period, which was more rapid for gastroscopy than colonoscopy. The self-efficacy scores for gastroscopy rapidly increased over the first few procedures, reaching a plateau after this period of time. For colonoscopy, there was a progressive increase in reported self-efficacy over the first three quartiles of procedures, followed by a drop in self-efficacy scores over the final quartile. DISCUSSION: The present study validated an Endoscopy Task Load Index that can be completed in <1 min. Practical implications of such a tool in endoscopy education include identifying periods of higher perceived exertion among novice endoscopists, facilitating appropriate levels of guidance from trainers. PMID:24619638

  20. Wireless Capsule Endoscopy Detects Meckel’s Diverticulum in a Child with Unexplained Intestinal Blood Loss

    Directory of Open Access Journals (Sweden)

    I. Xinias

    2012-10-01

    Full Text Available Meckel’s diverticulum (MD is the most common congenital anomaly of the gastrointestinal (GI tract, affecting about 2% of the population. Most cases of Meckel’s diverticula are asymptomatic. The diagnosis of symptomatic MD is often difficult to make. We report the case of an 8-year-old boy who presented with GI bleeding due to MD. The diagnostic difficulties after an initial negative endoscopic evaluation and the diagnostic value of the various endoscopic procedures are discussed. The patient had suffered from bright red stools for 20 h before hospital admission. GI scintigraphy with 99mTc-Na-pertechnetate was negative for heterotopic gastric tissue in the small bowel area. Colonoscopy performed in order to exclude Crohn’s disease was also negative. He was placed on ranitidine at a dose of 6 mg/kg body weight twice daily. The patient remained asymptomatic over a period of 6 months before he was readmitted due to macroscopic rectal bleeding. Upper endoscopy and colonoscopy used to investigate the source of bleeding showed normal macroscopic findings. Radiolabeling of blood constituents with 99mTc on delayed imaging showed radionucleotide concentration in the ascending and transverse colon suggestive of a lesion in the ileocecal area. Further investigation with the use of wireless capsule endoscopy revealed a MD. Wireless capsule endoscopy may thus be indicated for patients with GI blood loss when other diagnostic methods, such as upper and lower endoscopy and colonoscopy, have failed to identify the source of bleeding.

  1. The role of capnography in endoscopy patients undergoing nurse-administered propofol sedation

    DEFF Research Database (Denmark)

    Slagelse, Charlotte; Vilmann, Peter; Hornslet, Pernille

    2013-01-01

    . The existing literature on capnography for endoscopy patients sedated with nurse-administered propofol sedation (NAPS) is limited. Can the addition of capnography to standard monitoring during endoscopy with NAPS reduce the number, duration, and level of hypoxia. Materials and methods. This study...... capnography, were included in the analysis. The number and total duration of hypoxia was reduced by 39.3% and 21.1% in the intervention group compared to the control group (p > 0.05). No differences in actions taken against insufficient respiration were found. Changes in end-tidal carbon dioxide (R = 0.177, p......-value 0.05). Capnography is able to detect insufficient respiration that may lead to hypoxia prior to changes in pulse oximetry. However, due to a limited clinical benefit and additional costs associated with capnography, we do not find capnography necessary during the use of NAPS....

  2. The effect of the virtual mass term on the stability of the two-fluid model against perturbations

    International Nuclear Information System (INIS)

    Watanabe, Tadashi; Kutika, Yutaka

    1992-01-01

    The effect of the virtual mass term on the stability of the two-fluid model against perturbations is studied. Three types of virtual mass term in the momentum equation are discussed: two types of objective form and a simplified form. The differential equation system with no virtual mass term is ill-posed and the solution is unstable against perturbations. By introducing an objective form of the virtual mass term derived by Drew et al., it is shown that the equation system is rendered to be well-posed. The equation system is shown to be ill-posed, however, when a more recent definition of virtual mass acceleration of Drew and Lahey is applied. With a simplified form of the virtual mass term, which is composed only of temporal acceleration terms, the equation system is well-posed or ill-posed depending on velocities. A linear stability analysis is also performed for the implicit upwind finite difference scheme. A hypothetical accelerated flow problem is then numerically simulated by solving the discretized equation systems. It is shown that the solution can be numerically unstable even for the cases when the differential equation system is well-posed. The numerical stability of the solution must therefore be judged based on the spectral radius of the discretized equation system. (orig.)

  3. On-the-fly generation and rendering of infinite cities on the GPU

    KAUST Repository

    Steinberger, Markus

    2014-05-01

    In this paper, we present a new approach for shape-grammar-based generation and rendering of huge cities in real-time on the graphics processing unit (GPU). Traditional approaches rely on evaluating a shape grammar and storing the geometry produced as a preprocessing step. During rendering, the pregenerated data is then streamed to the GPU. By interweaving generation and rendering, we overcome the problems and limitations of streaming pregenerated data. Using our methods of visibility pruning and adaptive level of detail, we are able to dynamically generate only the geometry needed to render the current view in real-time directly on the GPU. We also present a robust and efficient way to dynamically update a scene\\'s derivation tree and geometry, enabling us to exploit frame-to-frame coherence. Our combined generation and rendering is significantly faster than all previous work. For detailed scenes, we are capable of generating geometry more rapidly than even just copying pregenerated data from main memory, enabling us to render cities with thousands of buildings at up to 100 frames per second, even with the camera moving at supersonic speed. © 2014 The Author(s) Computer Graphics Forum © 2014 The Eurographics Association and John Wiley & Sons Ltd. Published by John Wiley & Sons Ltd.

  4. On-the-fly generation and rendering of infinite cities on the GPU

    KAUST Repository

    Steinberger, Markus; Kenzel, Michael; Kainz, Bernhard K.; Wonka, Peter; Schmalstieg, Dieter

    2014-01-01

    In this paper, we present a new approach for shape-grammar-based generation and rendering of huge cities in real-time on the graphics processing unit (GPU). Traditional approaches rely on evaluating a shape grammar and storing the geometry produced as a preprocessing step. During rendering, the pregenerated data is then streamed to the GPU. By interweaving generation and rendering, we overcome the problems and limitations of streaming pregenerated data. Using our methods of visibility pruning and adaptive level of detail, we are able to dynamically generate only the geometry needed to render the current view in real-time directly on the GPU. We also present a robust and efficient way to dynamically update a scene's derivation tree and geometry, enabling us to exploit frame-to-frame coherence. Our combined generation and rendering is significantly faster than all previous work. For detailed scenes, we are capable of generating geometry more rapidly than even just copying pregenerated data from main memory, enabling us to render cities with thousands of buildings at up to 100 frames per second, even with the camera moving at supersonic speed. © 2014 The Author(s) Computer Graphics Forum © 2014 The Eurographics Association and John Wiley & Sons Ltd. Published by John Wiley & Sons Ltd.

  5. Virtually teaching virtual leadership

    DEFF Research Database (Denmark)

    Henriksen, Thomas Duus; Nielsen, Rikke Kristine; Børgesen, Kenneth

    2017-01-01

    This paper seeks to investigate the challenges to virtual collaboration and leadership on basis of findings from a virtual course on collaboration and leadership. The course used for this experiment was designed as a practical approach, which allowed participants to experience curriculum phenomena....... This experimental course provided insights into the challenges involved in virtual processes, and those experiences where used for addressing the challenges that virtual leadership is confronted with. Emphasis was placed on the reduction of undesired virtual distance and its consequences through affinity building....... We found that student scepticism appeared when a breakdown resulted in increasing virtual distance, and raises questions on how leaders might translate or upgrade their understandings of leadership to handling such increased distance through affinity building....

  6. Use of volume-rendered images in registration of nuclear medicine studies

    International Nuclear Information System (INIS)

    Wallis, J.W.; Miller, T.R.; Hsu, S.S.

    1995-01-01

    A simple operator-guided alignment technique based on volume-rendered images was developed to register tomographic nuclear medicine studies. For each of 2 three-dimensional data sets to be registered, volume-rendered images were generated in 3 orthogonal projections (x,y,z) using the method of maximum-activity projection. Registration was achieved as follows: (a) One of the rendering orientations (e.g. x) was chosen for manipulation; (b) The two dimensional rendering was translated and rotated under operator control to achieve the best alignment as determined by visual assessment; (c) This rotation and translation was then applied to the underlying three-dimensional data set, with updating of the rendered images in each of the orthogonal projections; (d) Another orientation was chosen, and the process repeated. Since manipulation was performed on the small two-dimensional rendered image, feedback was instantaneous. To aid in the visual alignment, difference images and flicker images (toggling between the two data sets) were displayed. Accuracy was assessed by analysis of separate clinical data sets acquired without patient movement. After arbitrary rotation and translation of one of the two data sets, the 2 data sets were registered. Mean registration error was 0.36 pixels, corresponding to a 2.44 mm registration error. Thus, accurate registration can be achieved in under 10 minutes using this simple technique. The accuracy of registration was assessed with use of duplicate SPECT studies originating from separate reconstructions of the data from each of the detectors of a triple-head gamma camera

  7. Integration of virtual and real scenes within an integral 3D imaging environment

    Science.gov (United States)

    Ren, Jinsong; Aggoun, Amar; McCormick, Malcolm

    2002-11-01

    The Imaging Technologies group at De Montfort University has developed an integral 3D imaging system, which is seen as the most likely vehicle for 3D television avoiding psychological effects. To create real fascinating three-dimensional television programs, a virtual studio that performs the task of generating, editing and integrating the 3D contents involving virtual and real scenes is required. The paper presents, for the first time, the procedures, factors and methods of integrating computer-generated virtual scenes with real objects captured using the 3D integral imaging camera system. The method of computer generation of 3D integral images, where the lens array is modelled instead of the physical camera is described. In the model each micro-lens that captures different elemental images of the virtual scene is treated as an extended pinhole camera. An integration process named integrated rendering is illustrated. Detailed discussion and deep investigation are focused on depth extraction from captured integral 3D images. The depth calculation method from the disparity and the multiple baseline method that is used to improve the precision of depth estimation are also presented. The concept of colour SSD and its further improvement in the precision is proposed and verified.

  8. The Design and Implementation of Virtual Roaming in Yunnan Diqing Tibetan traditional Villages

    Directory of Open Access Journals (Sweden)

    Cao Lucheng

    2018-01-01

    Full Text Available Traditional residence is the continuation of intangible cultural heritage and the primitive soil for development. At present, the protection and inheritance of traditional villages have been impacted by the process of modernization, and the phenomenon of assimilation is very serious. This article takes the above questions as the breakthrough point, and then analyzes why and how to use virtual reality technology to better solve the above problems, and take the Yunnan Diqing Tibetan traditional dwellings as the specific example to explore. First, using VR technology, with real images and sound, the paper simulate a near real virtual world. Secondly, we collect a large amount of real image information, and make the visualization model of building by using 3DMAX software platform, UV Mapping and Rendering optimization. Finally, the Vizard virtual reality development platform was used to establish the roaming system and realize the virtual interaction. The roaming system was posted online so that overcome the disadvantages of not intuitive and low capability of interaction, and these new ideas can give a whole new meaning in the protection projects of the cultural relic buildings. At the same time, visitors could enjoy the "Dian-style" architectural style and cultural connotation of dwelling house in Diqing Yunnan.

  9. NOViSE: a virtual natural orifice transluminal endoscopic surgery simulator.

    Science.gov (United States)

    Korzeniowski, Przemyslaw; Barrow, Alastair; Sodergren, Mikael H; Hald, Niels; Bello, Fernando

    2016-12-01

    Natural orifice transluminal endoscopic surgery (NOTES) is a novel technique in minimally invasive surgery whereby a flexible endoscope is inserted via a natural orifice to gain access to the abdominal cavity, leaving no external scars. This innovative use of flexible endoscopy creates many new challenges and is associated with a steep learning curve for clinicians. We developed NOViSE-the first force-feedback-enabled virtual reality simulator for NOTES training supporting a flexible endoscope. The haptic device is custom-built, and the behaviour of the virtual flexible endoscope is based on an established theoretical framework-the Cosserat theory of elastic rods. We present the application of NOViSE to the simulation of a hybrid trans-gastric cholecystectomy procedure. Preliminary results of face, content and construct validation have previously shown that NOViSE delivers the required level of realism for training of endoscopic manipulation skills specific to NOTES. VR simulation of NOTES procedures can contribute to surgical training and improve the educational experience without putting patients at risk, raising ethical issues or requiring expensive animal or cadaver facilities. In the context of an experimental technique, NOViSE could potentially facilitate NOTES development and contribute to its wider use by keeping practitioners up to date with this novel surgical technique. NOViSE is a first prototype, and the initial results indicate that it provides promising foundations for further development.

  10. Diagnosis of Helicobacter pylori-related chronic gastritis, gastric adenoma and early gastric cancer by magnifying endoscopy.

    Science.gov (United States)

    Soma, Nei

    2016-10-01

    Evaluating the prevalence and severity of gastritis by endoscopy is useful for estimating the risk of gastric cancer (GC). Moreover, understanding the endoscopic appearances of gastritis is important for diagnosing GC due to the fact that superficial mucosal lesions mimicing gastritis (gastritis-like lesions) are quite difficult to be detected even with optimum preparation and the best technique, and in such cases tissue biopsy is often not very accurate for the diagnosis of gastric epithelial neoplasia. Magnifying endoscopy is a highly accurate technique for the detection of early gastric cancer (EGC). Recent reports have described that various novel endoscopic markers which, visualized by magnifying endoscopy with image-enhanced system (ME-IEE), can predict specific histopathological findings. Using ME-IEE with vessels and surface classification system (VSCS) may represent an excellent diagnostic performance with high confidence and good reproducibility to the endoscopists if performed under consistent conditions, including observation under maximal magnification. The aim of this review was to discuss how to identify high-risk groups for GC by endoscopy, and how to detect effectively signs of suspicious lesions by conventional white light imaging (C-WLI) or chromoendoscopy (CE). Furthermore, to characterize suspicious lesions using ME-IEE using the criteria and classification of EGC based upon VSCS. © 2016 Chinese Medical Association Shanghai Branch, Chinese Society of Gastroenterology, Renji Hospital Affiliated to Shanghai Jiaotong University School of Medicine and John Wiley & Sons Australia, Ltd.

  11. Baby Shampoo versus Commercial Anti-fogging Solution to Prevent Fogging during Nasal Endoscopy: A Randomized Double-Blinded, Matched-Pair, Equivalent Trial.

    Science.gov (United States)

    Chainansamit, Seksun; Piromchai, Patorn; Anantpinijwatna, Intira; Kasemsiri, Pornthep; Thanaviratananich, Sanguansak

    2015-08-01

    To compare the minimization of the fog condensation during nasal endoscopy between a commercial anti-fogging agent and baby shampoo. This randomized double-blinded matched pair study was conducted at the Department of Otorhinolaryngology, Faculty of Medicine, Khon Kaen University during February 4, 2013 to March 14, 2013. The commercial anti-fogging solution (Ultrastop®) and baby shampoo solution (Johnson's® no more tear®) were compared. A computer generated randomization was performed to select the solution applying on the lens for nasal endoscopy of the right nasal cavity. The other solution was then used for the left one. Three passes of endoscopy were performed to examine the floor of the nose, the sphenoethmoidal recess and the middle meatus area which spent about 30 seconds for each time of endoscopy. The time to become foggy on the lens and the preferred solution assessed by the endoscopists were recorded. There were 71 eligible patients recruited in the study, 37 males (52.1%) and 34 females (47.9%). There was no fogging during a 30-second nasal endoscopy either by baby shampoo or commercial anti-fogging solution. However, 9.86% (95% C12.75-16.97) of endoscopists preferred commercial anti-fogging agent, 7.04% (95% CI 0.94-13.14) preferred baby shampoo and 83.10% (95% CI 74.16-92.03) had equal satisfaction. Both agents had no statistically significant difference for preventing foggy on the lens. Baby shampoo is an effective agent to prevent fogging during nasal endoscopy and comparable with the commercial anti-fogging agent.

  12. The diachronic path: the virtual restoration of the Spanish walls of Ortigia

    Directory of Open Access Journals (Sweden)

    Rita Valenti

    2015-01-01

    Full Text Available There are architectural works whose mark on the area is no longer impressed by matter and for which interventions cannot be defined in a material restoration. There are important buildings which having being in fact destroyed by the will of community decision-making, with complex processes and often controversies, have literally cancelled out pieces ofhistory. In the absence of matter, the representation conducted using the latest digital technology, which has made a significant contribution to the documentation of these works for which a virtual restoration helps tokeep the record alive. The study focuses on the impressive work of the Spanish walls that for more than three centuries have marked the city of Syracuse and which the political events of the late nineteenth century have largely destroyed. The goal is to render this cultural heritage available, in the same way as a material restoration would, through virtual reality.

  13. HapTip: Displaying Haptic Shear Forces at the Fingertips for Multi-Finger Interaction in Virtual Environments

    Directory of Open Access Journals (Sweden)

    Adrien eGirard

    2016-04-01

    Full Text Available The fingertips are one of the most important and sensitive parts of our body.They are the first stimulated areas of the hand when we interact with our environment.Providing haptic feedback to the fingertips in virtual reality could thus drastically improve perception and interaction with virtual environments.In this paper, we present a modular approach called HapTip to display such haptic sensations at the level of the fingertips.This approach relies on a wearable and compact haptic device able to simulate 2 Degree of Freedom (DoF shear forces on the fingertip with a displacement range of +/- 2 mm. Several modules can be added and used jointly in order to address multi-finger and/or bimanual scenarios in virtual environments.For that purpose, we introduce several haptic rendering techniques to cover different cases of 3D interaction such as touching a rough virtual surface, or feeling the inertia or weight of a virtual object.In order to illustrate the possibilities offered by HapTip, we provide four use cases focused on touching or grasping virtual objects.To validate the efficiency of our approach, we also conducted experiments to assess the tactile perception obtained with HapTip.Our results show that participants can successfully discriminate the directions of the 2 DoF stimulation of our haptic device.We found also that participants could well perceive different weights of virtual objects simulated using two HapTip devices. We believe that HapTip could be used in numerous applications in virtual reality for which 3D manipulation and tactile sensations are often crucial, such as in virtual prototyping or virtual training.

  14. Method of producing hydrogen, and rendering a contaminated biomass inert

    Science.gov (United States)

    Bingham, Dennis N [Idaho Falls, ID; Klingler, Kerry M [Idaho Falls, ID; Wilding, Bruce M [Idaho Falls, ID

    2010-02-23

    A method for rendering a contaminated biomass inert includes providing a first composition, providing a second composition, reacting the first and second compositions together to form an alkaline hydroxide, providing a contaminated biomass feedstock and reacting the alkaline hydroxide with the contaminated biomass feedstock to render the contaminated biomass feedstock inert and further producing hydrogen gas, and a byproduct that includes the first composition.

  15. Social Gaming and Learning Applications: A Driving Force for the Future of Virtual and Augmented Reality?

    Science.gov (United States)

    Dörner, Ralf; Lok, Benjamin; Broll, Wolfgang

    Backed by a large consumer market, entertainment and education applications have spurred developments in the fields of real-time rendering and interactive computer graphics. Relying on Computer Graphics methodologies, Virtual Reality and Augmented Reality benefited indirectly from this; however, there is no large scale demand for VR and AR in gaming and learning. What are the shortcomings of current VR/AR technology that prevent a widespread use in these application areas? What advances in VR/AR will be necessary? And what might future “VR-enhanced” gaming and learning look like? Which role can and will Virtual Humans play? Concerning these questions, this article analyzes the current situation and provides an outlook on future developments. The focus is on social gaming and learning.

  16. Image-based path planning for automated virtual colonoscopy navigation

    Science.gov (United States)

    Hong, Wei

    2008-03-01

    Virtual colonoscopy (VC) is a noninvasive method for colonic polyp screening, by reconstructing three-dimensional models of the colon using computerized tomography (CT). In virtual colonoscopy fly-through navigation, it is crucial to generate an optimal camera path for efficient clinical examination. In conventional methods, the centerline of the colon lumen is usually used as the camera path. In order to extract colon centerline, some time consuming pre-processing algorithms must be performed before the fly-through navigation, such as colon segmentation, distance transformation, or topological thinning. In this paper, we present an efficient image-based path planning algorithm for automated virtual colonoscopy fly-through navigation without the requirement of any pre-processing. Our algorithm only needs the physician to provide a seed point as the starting camera position using 2D axial CT images. A wide angle fisheye camera model is used to generate a depth image from the current camera position. Two types of navigational landmarks, safe regions and target regions are extracted from the depth images. Camera position and its corresponding view direction are then determined using these landmarks. The experimental results show that the generated paths are accurate and increase the user comfort during the fly-through navigation. Moreover, because of the efficiency of our path planning algorithm and rendering algorithm, our VC fly-through navigation system can still guarantee 30 FPS.

  17. Nasal Physiology

    Science.gov (United States)

    ... Caregivers Contact ARS HOME ANATOMY Nasal Anatomy Sinus Anatomy Nasal Physiology Nasal Endoscopy Skull Base Anatomy Virtual Anatomy Disclosure ... Patient Education About this Website Font Size + - Home > ANATOMY > Nasal Physiology Nasal Anatomy Sinus Anatomy Nasal Physiology Nasal Endoscopy ...

  18. Visualization and simulation techniques for surgical simulators using actual patient's data.

    Science.gov (United States)

    Radetzky, Arne; Nürnberger, Andreas

    2002-11-01

    Because of the increasing complexity of surgical interventions research in surgical simulation became more and more important over the last years. However, the simulation of tissue deformation is still a challenging problem, mainly due to the short response times that are required for real-time interaction. The demands to hard and software are even larger if not only the modeled human anatomy is used but the anatomy of actual patients. This is required if the surgical simulator should be used as training medium for expert surgeons rather than students. In this article, suitable visualization and simulation methods for surgical simulation utilizing actual patient's datasets are described. Therefore, the advantages and disadvantages of direct and indirect volume rendering for the visualization are discussed and a neuro-fuzzy system is described, which can be used for the simulation of interactive tissue deformations. The neuro-fuzzy system makes it possible to define the deformation behavior based on a linguistic description of the tissue characteristics or to learn the dynamics by using measured data of real tissue. Furthermore, a simulator for minimally-invasive neurosurgical interventions is presented that utilizes the described visualization and simulation methods. The structure of the simulator is described in detail and the results of a system evaluation by an experienced neurosurgeon--a quantitative comparison between different methods of virtual endoscopy as well as a comparison between real brain images and virtual endoscopies--are given. The evaluation proved that the simulator provides a higher realism of the visualization and simulation then other currently available simulators. Copyright 2002 Elsevier Science B.V.

  19. Combined high-field intraoperative magnetic resonance imaging and endoscopy increase extent of resection and progression-free survival for pituitary adenomas

    Science.gov (United States)

    Sylvester, Peter T.; Evans, John A.; Zipfel, Gregory J.; Chole, Richard A.; Uppaluri, Ravindra; Haughey, Bruce H.; Getz, Anne E.; Silverstein, Julie; Rich, Keith M.; Kim, Albert H.; Dacey, Ralph G.

    2014-01-01

    Purpose The clinical benefit of combined intraoperative magnetic resonance imaging (iMRI) and endoscopy for transsphenoidal pituitary adenoma resection has not been completely characterized. This study assessed the impact of microscopy, endoscopy, and/or iMRI on progression-free survival, extent of resection status (gross-, near-, and subtotal resection), and operative complications. Methods Retrospective analyses were performed on 446 transsphenoidal pituitary adenoma surgeries at a single institution between 1998 and 2012. Multivariate analyses were used to control for baseline characteristics, differences during extent of resection status, and progression-free survival analysis. Results Additional surgery was performed after iMRI in 56/156 cases (35.9 %), which led to increased extent of resection status in 15/156 cases (9.6 %). Multivariate ordinal logistic regression revealed no increase in extent of resection status following iMRI or endoscopy alone; however, combining these modalities increased extent of resection status (odds ratio 2.05, 95 % CI 1.21–3.46) compared to conventional transsphenoidal microsurgery. Multivariate Cox regression revealed that reduced extent of resection status shortened progression-free survival for near- versus gross-total resection [hazard ratio (HR) 2.87, 95 % CI 1.24–6.65] and sub- versus near-total resection (HR 2.10; 95 % CI 1.00–4.40). Complication comparisons between microscopy, endoscopy, and iMRI revealed increased perioperative deaths for endoscopy versus microscopy (4/209 and 0/237, respectively), but this difference was non-significant considering multiple post hoc comparisons (Fisher exact, p = 0.24). Conclusions Combined use of endoscopy and iMRI increased pituitary adenoma extent of resection status compared to conventional transsphenoidal microsurgery, and increased extent of resection status was associated with longer progression-free survival. Treatment modality combination did not significantly impact

  20. Rendering Visible: Painting and Sexuate Subjectivity

    Science.gov (United States)

    Daley, Linda

    2015-01-01

    In this essay, I examine Luce Irigaray's aesthetic of sexual difference, which she develops by extrapolating from Paul Klee's idea that the role of painting is to render the non-visible rather than represent the visible. This idea is the premise of her analyses of phenomenology and psychoanalysis and their respective contributions to understanding…

  1. Free-viewpoint depth image based rendering

    NARCIS (Netherlands)

    Zinger, S.; Do, Q.L.; With, de P.H.N.

    2010-01-01

    In 3D TV research, one approach is to employ multiple cameras for creating a 3D multi-view signal with the aim to make interactive free-viewpoint selection possible in 3D TV media. This paper explores a new rendering algorithm that enables to compute a free-viewpoint between two reference views from

  2. Influence of rendering methods on yield and quality of chicken fat recovered from broiler skin

    Directory of Open Access Journals (Sweden)

    Liang-Kun Lin

    2017-06-01

    Full Text Available Objective In order to utilize fat from broiler byproducts efficiently, it is necessary to develop an appropriate rendering procedure and establish quality information for the rendered fat. A study was therefore undertaken to evaluate the influence of rendering methods on the amounts and general properties of the fat recovered from broiler skin. Methods The yield and quality of the broiler skin fat rendered through high and lower energy microwave rendering (3.6 W/g for 10 min and 2.4 W/g for 10 min for high power microwave rendering (HPMR and high power microwave rendering (LPMR, respectively, oven baking (OB, at 180°C for 40 min, and water cooking (WC, boiling for 40 min were compared. Results Microwave-rendered skin exhibited the highest yields and fat recovery rates, followed by OB, and WC fats (p<0.05. HPMR fat had the highest L*, a*, and b* values, whereas WC fat had the highest moisture content, acid values, and thiobarbituric acid (TBA values (p<0.05. There was no significant difference in the acid value, peroxide value, and TBA values between HPMR and LPMR fats. Conclusion Microwave rendering at a power level of 3.6 W/g for 10 min is suggested base on the yield and quality of chicken fat.

  3. Usefulness of Double-Balloon Endoscopy in the Postoperative Gastrointestinal Tract

    Directory of Open Access Journals (Sweden)

    Masaki Endo

    2011-01-01

    Full Text Available Background. The small intestine has been considered to be a highly difficult organ to visualize in imaging examinations due to its anatomical location compared with the stomach and the colon. In recent years, many imaging modalities have become available, such as CT enterography, MR enterography, capsule endoscopy (CE, and double-balloon endoscopy (DBE. Patients and Methods. DBE was performed in the postoperative intestines of 91 patients (128 DBE examinations at Iwate Medical University between 2004 and 2010. There were 61 male and 30 female patients, and their mean age was 69.7 years (range: 30–80 years. Results. A total of 124 DBE examinations were performed with endoscope insertion into the reconstructed intestines. The endoscope reached the blind end in 115 of 124 examinations, (92.7%. There were 17 patients with obscure gastrointestinal bleeding in whom 30 DBE examinations were performed. The bleeding site was identified in 12 patients (70.6%. Nine patients underwent endoscopic treatment. Hemostasis was achieved in all patients. Conclusion. DBE is very useful modality for the assessment and application of endotherapy to areas of the small bowel which have been altered by surgery.

  4. Videofluoroscopy versus upper G.I. endoscopy: A comparative study as a diagnostic tool in patients presenting with dysphagia

    OpenAIRE

    Sharwak Ramlan; Sai Manohar; Gangadhara Somayaji

    2015-01-01

    Background and Objective: Dysphagia is a major symptom in many of the patients coming to the hospital. There can be various causes of dysphagia and its accurate diagnosis shows the way for the necessary treatment. Videofluoroscopy and upper gastrointestinal (GI) endoscopy are the two most commonly employed primary investigating modalities in assessing dysphagia. The objective of the study was to compare videofluoroscopy and upper GI endoscopy and establish a primary diagnostic tool for assess...

  5. Virtual processes and superradiance in spin-boson modes

    International Nuclear Information System (INIS)

    Alcalde, M. Aparicio; Kullock, R.; Svaiter, N.F.

    2008-01-01

    We consider spin-boson models composed by a single bosonic mode and an ensemble of N identical two-level atoms. The situation where the coupling between the bosonic mode and the atoms generates real and virtual processes is studied, where the whole system is in thermal equilibrium with a reservoir at temperature β -1 . Phase transitions from ordinary fluorescence to super radiant phase in three different models is investigated. First a model where the coupling between the bosonic mode and the j - th atom is via the pseudo-spin operator σ (j) z is studied. Second, we investigate the generalized Dicke model, introducing different coupling constants between the single mode bosonic field and the environment, g 1 and g 2 for rotating and counter-rotating terms, respectively. Finally it is considered a modified version of the generalized Dicke model with intensity-dependent coupling in the rotating terms. In the first model the zero mode contributes to render the canonical entropy a negative quantity for low temperatures. The last two models presents phase transitions, even when only Hamiltonian terms which generates virtual processes are considered. (author)

  6. The Clinical Risks of Infection Associated with Endoscopy

    Directory of Open Access Journals (Sweden)

    Alistair E Cowen

    2001-01-01

    Full Text Available The cleaning of flexible endoscopes is difficult and time consuming. Any method of attempted sterilization or high level disinfection will fail if prior cleaning has been defective. Inadequate reprocessing of endoscopes may result in patient to patient transmission of serious bacterial and viral diseases or infection with endemic hospital pathogens. Antibiotic prophylaxis is required to prevent septicemia and bacterial endocarditis in high risk patients undergoing specific endoscopic procedures. Prevention of serious endoscopy-associated clinical infections requires strict compliance with detailed reprocessing protocols by specially trained nursing staff.

  7. Beaming teaching application: recording techniques for spatial xylophone sound rendering

    DEFF Research Database (Denmark)

    Markovic, Milos; Madsen, Esben; Olesen, Søren Krarup

    2012-01-01

    BEAMING is a telepresence research project aiming at providing a multimodal interaction between two or more participants located at distant locations. One of the BEAMING applications allows a distant teacher to give a xylophone playing lecture to the students. Therefore, rendering of the xylophon...... to spatial improvements mainly in terms of the Apparent Source Width (ASW). Rendered examples are subjectively evaluated in listening tests by comparing them with binaural recording....

  8. Capsule endoscopy for the diagnosis and follow up of crohn’s disease

    DEFF Research Database (Denmark)

    Jensen, Michael Dam; Brodersen, Jacob; Kjeldsen, Jens

    2017-01-01

    Capsule endoscopy (CE) has revolutionized the diagnosis and monitoring of small bowel Crohn’s disease (CD). the procedure is patient friendly and noninvasive, and compared to cross-sectional imaging, CE allows a direct and detailed evaluation of the entire small bowel mucosa witha high sensitivit...

  9. Correlation between predicted and actual consequences of capsule endoscopy on patient management

    NARCIS (Netherlands)

    Westerhof, J.; Weersma, R. K.; Thijs, W. J.; Limburg, A. J.; Koornstra, J. J.; de Graaf, A.P.

    Background. Capsule endoscopy (CE) is a relatively new diagnostic modality in the evaluation of patients with suspected small bowel pathology. It is unclear to what extent physicians are able to predict the clinical consequences of CE on patient management. Methods. In this prospective study, 180

  10. Chromium Renderserver: Scalable and Open Source Remote RenderingInfrastructure

    Energy Technology Data Exchange (ETDEWEB)

    Paul, Brian; Ahern, Sean; Bethel, E. Wes; Brugger, Eric; Cook,Rich; Daniel, Jamison; Lewis, Ken; Owen, Jens; Southard, Dale

    2007-12-01

    Chromium Renderserver (CRRS) is software infrastructure thatprovides the ability for one or more users to run and view image outputfrom unmodified, interactive OpenGL and X11 applications on a remote,parallel computational platform equipped with graphics hardwareaccelerators via industry-standard Layer 7 network protocolsand clientviewers. The new contributions of this work include a solution to theproblem of synchronizing X11 and OpenGL command streams, remote deliveryof parallel hardware-accelerated rendering, and a performance analysis ofseveral different optimizations that are generally applicable to avariety of rendering architectures. CRRSis fully operational, Open Sourcesoftware.

  11. Virtual pinhole confocal microscope

    Energy Technology Data Exchange (ETDEWEB)

    George, J.S.; Rector, D.M.; Ranken, D.M. [Los Alamos National Lab., NM (United States). Biophysics Group; Peterson, B. [SciLearn Inc. (United States); Kesteron, J. [VayTech Inc. (United States)

    1999-06-01

    Scanned confocal microscopes enhance imaging capabilities, providing improved contrast and image resolution in 3-D, but existing systems have significant technical shortcomings and are expensive. Researchers at Los Alamos National Laboratory have developed a novel approach--virtual pinhole confocal microscopy--that uses state of the art illumination, detection, and data processing technologies to produce an imager with a number of advantages: reduced cost, faster imaging, improved efficiency and sensitivity, improved reliability and much greater flexibility. Work at Los Alamos demonstrated proof of principle; prototype hardware and software have been used to demonstrate technical feasibility of several implementation strategies. The system uses high performance illumination, patterned in time and space. The authors have built functional confocal imagers using video display technologies (LCD or DLP) and novel scanner based on a micro-lens array. They have developed a prototype system for high performance data acquisition and processing, designed to support realtime confocal imaging. They have developed algorithms to reconstruct confocal images from a time series of spatially sub-sampled images; software development remains an area of active development. These advances allow the collection of high quality confocal images (in fluorescence, reflectance and transmission modes) with equipment that can inexpensively retrofit to existing microscopes. Planned future extensions to these technologies will significantly enhance capabilities for microscopic imaging in a variety of applications, including confocal endoscopy, and confocal spectral imaging.

  12. Prophylactic antibiotics for endoscopy-associated peritonitis in peritoneal dialysis patients.

    Directory of Open Access Journals (Sweden)

    Hsin-Hsu Wu

    Full Text Available INTRODUCTION: Continuous ambulatory peritoneal dialysis (CAPD peritonitis may develop after endoscopic procedures, and the benefit of prophylactic antibiotics is unclear. In the present study, we investigated whether prophylactic antibiotics reduce the incidence of peritonitis in these patients. PATIENTS AND METHODS: We retrospectively reviewed all endoscopic procedures, including esophagogastroduodenoscopy (EGD, colonoscopy, sigmoidoscopy, cystoscopy, hysteroscopy, and hysteroscopy-assisted intrauterine device (IUD implantation/removal, performed in CAPD patients at Chang Gung Memorial Hospital, Taiwan, between February 2001 and February 2012. RESULTS: Four hundred and thirty-three patients were enrolled, and 125 endoscopies were performed in 45 patients. Eight (6.4% peritonitis episodes developed after the examination. Antibiotics were used in 26 procedures, and none of the patients had peritonitis (0% vs. 8.1% without antibiotic use; p=0.20. The peritonitis rate was significantly higher in the non-EGD group than in the EGD group (15.9% [7/44] vs. 1.2% [1/81]; p<0.005. Antibiotic use prior to non-EGD examinations significantly reduced the endoscopy-associated peritonitis rate compared to that without antibiotic use (0% [0/16] vs. 25% [7/28]; p<0.05. Peritonitis only occurred if invasive procedures were performed, such as biopsy, polypectomy, or IUD implantation, (noninvasive procedures, 0% [0/20] vs. invasive procedures, 30.4% [7/23]; p<0.05. No peritonitis was noted if antibiotics were used prior to examination with invasive procedures (0% [0/10] vs. 53.8% [7/13] without antibiotic use; p<0.05. Although not statistically significant, antibiotics may play a role in preventing gynecologic procedure-related peritonitis (antibiotics, 0% [0/4] vs. no antibiotics, 55.6% [5/9]; p=0.10. CONCLUSION: Antibiotic prophylaxis significantly reduced endoscopy-associated PD peritonitis in the non-EGD group. Endoscopically assisted invasive procedures, such

  13. [Design of extracorporeal apparatus of capsule endoscopy based on ARM+FPGA].

    Science.gov (United States)

    Wang, Shenghua; Zhang, Sijie; Wang, Yue; Wang, Zhenxing

    2011-10-01

    Considering that the patients would bear the annoyance of fixed posture for long time when they are examined with gastrointestinal wireless endoscopy, even though portable devices have been developed, the treatments still depend on PC so much, we proposed an embedded solution based on ARM + FPGA. It used embedded ARM9 S3C2440 as processor core, collected images from digestive tract through capsule endoscopy which can be swallowed down there, and wirelessly transferred these images to the receiving system, then used video decoder chip SAA7114H for analog of NTSC video image decode. And under FPGA's logic controlling, effective digital video signal was transferred to S3C2440 for further treatment. Finally within the embedded Linux environment, we programmed the visual user interfaces using the QT/Embedded, realizing the offline record of the real-time video images of digestive tract portable and preferences. It can make patients move more freely and even without PC when examining. In addition, the method greatly improves the efficiency of the doctor, and is more intelligent and with more humane nature.

  14. Portal hypertensive enteropathy diagnosed by capsule endoscopy and demonstration of the ileal changes after transjugular intrahepatic portosystemic shunt placement: a case report

    Directory of Open Access Journals (Sweden)

    Carella Alessandra

    2011-03-01

    Full Text Available Abstract Introduction Recent data suggest that mucosal abnormalities can occur even in the duodenum, jejunum, and distal ileum of cirrhosis patients. We present a case of portal hypertensive enteropathy in a cirrhosis patient shown by capsule endoscopy and the effect of transjugular intrahepatic portosystemic shunt on the ileal pictures. Case presentation An 83-year-old Caucasian woman was admitted to our hospital for anemia and a positive fecal occult blood test. An upper gastrointestinal endoscopy revealed small varices without bleeding signs and hypertensive gastropathy. Colonoscopy was negative. To rule out any other cause of bleeding, capsule endoscopy was performed; capsule endoscopy revealed severe hyperemia of the jejunum-ileal mucosa with active bleeding. Because of the persistence of anemia and the frequent blood transfusions, not responding to β-blocker drugs or octreotide infusion, a transjugular intrahepatic portosystemic shunt was performed. Anemia improved quickly after the transjugular intrahepatic portosystemic shunt, and no further blood transfusion was necessary in the follow-up. The patient developed portal encephalopathy two months later and was readmitted to our department. We repeated the capsule endoscopy that showed a significant improvement of the gastric and ileal mucosa without any signs of bleeding. Conclusion Hypertensive enteropathy is a rare condition, but it seems more common with the introduction of capsule endoscopy in clinical practice. This case shows that the jejunum can be a source of bleeding in cirrhosis patients, and this is the first demonstration of its resolution after transjugular intrahepatic portosystemic shunt placement.

  15. Fifteen-Year-Old Male with Type 2 Autoimmune Pancreatitis: An Argument for Endoscopy

    Directory of Open Access Journals (Sweden)

    Nathan T. Kolasinski

    2017-05-01

    Full Text Available Type 2 autoimmune pancreatitis, an increasingly recognized etiology of pancreatitis in patients less than 20 years old, has characteristically been diagnosed with the histological finding of duct-centric pancreatitis in a patient who lacks elevated serum immunoglobulin G4. We present the case of a nonobese 15-year-old male, without any chronic medical conditions, who presented with the chief complaint of abdominal pain. The laboratory study results were remarkable for a lipase level of 5,419 U/L and a γ-glutamyl transferase level of 373 U/L. Magnetic resonance cholangiopancreatography revealed delayed contrast enhancement of the pancreas, diffuse parenchymal enlargement, and lack of normal lobulation. The patient’s serum immunoglobulin G4 level was found to be 66 mg/dL, which was within normal limits and supportive of a diagnosis of type 2 autoimmune pancreatitis. Despite the absence of intestinal complaints, the patient underwent subsequent endoscopy due to the correlation of type 2 autoimmune pancreatitis with inflammatory bowel disease that has been described in recent literature. Pan-colonic mild colitis was visualized, and the patient began treatment with steroids, to which he quickly responded. Performing endoscopy on this patient allowed for confident initiation of early therapy for both autoimmune pancreatitis and inflammatory bowel disease, and may have limited further surgical intervention and disease progression. For these reasons, this case highlights the utility of endoscopy in pediatric patients with suspected type 2 autoimmune pancreatitis, even in the absence of intestinal symptoms.

  16. Impact of the endoscopist's experience on the negative predictive value of capsule endoscopy.

    Science.gov (United States)

    Velayos Jiménez, Benito; Alcaide Suárez, Noelia; González Redondo, Guillermo; Fernández Salazar, Luis; Aller de la Fuente, Rocío; Del Olmo Martínez, Lourdes; Ruiz Rebollo, Lourdes; González Hernández, José Manuel

    2017-01-01

    The impact of the accumulated experience of the capsule endoscopy (CE) reader on the accuracy of this test is discussed. To determine whether the negative predictive value of CE findings changes along the learning curve. We reviewed the first 900 CE read by 3 gastroenterologists experienced in endoscopy over 8 years. These 900 CE were divided into 3 groups (300 CE each): group 1 consisted of the sum of the first 100 CE read by each of the 3 endoscopists; group 2, the sum of the second 100 and groups 3, the sum of the third 100. Patients with normal CE were monitored for at least 28 months to estimate the negative predictive value. A total of 54 (18%) CE in group 1, 58 (19.3%) in group 2 and 47 (15.6%) in group 3 were normal, although only 34 patients in group 1, 38 in group 2 and 36 in group 3 with normal CE completed follow up and were eventually studied. The negative predictive value was 88.2% in group 1, 89.5% in group 2 and 97% in group 3 (P>.05). The negative predictive value tended to increase, but remained high and did not change significantly after the first 100 when readers are experienced in conventional endoscopy and have preliminary specific training. Copyright © 2016 Elsevier España, S.L.U., AEEH y AEG. All rights reserved.

  17. Endoscopic treatment of chronic pancreatitis: European Society of Gastrointestinal Endoscopy (ESGE) Clinical Guideline

    NARCIS (Netherlands)

    Dumonceau, J.-M.; Delhaye, M.; Tringali, A.; Dominguez-Munoz, J. E.; Poley, J.-W.; Arvanitaki, M.; Costamagna, G.; Costea, F.; Devière, J.; Eisendrath, P.; Lakhtakia, S.; Reddy, N.; Fockens, P.; Ponchon, T.; Bruno, M.

    2012-01-01

    Background and aims: Clarification of the position of the European Society of Gastrointestinal Endoscopy (ESGE) regarding the interventional options available for treating patients with chronic pancreatitis. Methods: Systematic literature search to answer explicit key questions with levels of

  18. An asymmetric resonant coupling wireless power transmission link for Micro-Ball Endoscopy.

    Science.gov (United States)

    Sun, Tianjia; Xie, Xiang; Li, Guolin; Gu, Yingke; Deng, Yangdong; Wang, Ziqiang; Wang, Zhihua

    2010-01-01

    This paper investigates the design and optimization of a wireless power transmission link targeting Micro-Ball Endoscopy applications. A novel asymmetric resonant coupling structure is proposed to deliver power to an endoscopic Micro-Ball system for image read-out after it is excreted. Such a technology enables many key medical applications with stringent requirements for small system volume and high power delivery efficiency. A prototyping power transmission sub-system of the Micro-Ball system was implemented. It consists of primary coil, middle resonant coil, and cube-like full-direction secondary receiving coils. Our experimental results proved that 200mW of power can be successfully delivered. Such a wireless power transmission capability could satisfy the requirements of the Micro-Ball based endoscopy application. The transmission efficiency is in the range of 41% (worst working condition) to 53% (best working condition). Comparing to conventional structures, Asymmetric Resonant Coupling Structure improves power efficiency by 13%.

  19. Half-unit weighted bilinear algorithm for image contrast enhancement in capsule endoscopy

    Science.gov (United States)

    Rukundo, Olivier

    2018-04-01

    This paper proposes a novel enhancement method based exclusively on the bilinear interpolation algorithm for capsule endoscopy images. The proposed method does not convert the original RBG image components to HSV or any other color space or model; instead, it processes directly RGB components. In each component, a group of four adjacent pixels and half-unit weight in the bilinear weighting function are used to calculate the average pixel value, identical for each pixel in that particular group. After calculations, groups of identical pixels are overlapped successively in horizontal and vertical directions to achieve a preliminary-enhanced image. The final-enhanced image is achieved by halving the sum of the original and preliminary-enhanced image pixels. Quantitative and qualitative experiments were conducted focusing on pairwise comparisons between original and enhanced images. Final-enhanced images have generally the best diagnostic quality and gave more details about the visibility of vessels and structures in capsule endoscopy images.

  20. Virtual goods recommendations in virtual worlds.

    Science.gov (United States)

    Chen, Kuan-Yu; Liao, Hsiu-Yu; Chen, Jyun-Hung; Liu, Duen-Ren

    2015-01-01

    Virtual worlds (VWs) are computer-simulated environments which allow users to create their own virtual character as an avatar. With the rapidly growing user volume in VWs, platform providers launch virtual goods in haste and stampede users to increase sales revenue. However, the rapidity of development incurs virtual unrelated items which will be difficult to remarket. It not only wastes virtual global companies' intelligence resources, but also makes it difficult for users to find suitable virtual goods fit for their virtual home in daily virtual life. In the VWs, users decorate their houses, visit others' homes, create families, host parties, and so forth. Users establish their social life circles through these activities. This research proposes a novel virtual goods recommendation method based on these social interactions. The contact strength and contact influence result from interactions with social neighbors and influence users' buying intention. Our research highlights the importance of social interactions in virtual goods recommendation. The experiment's data were retrieved from an online VW platform, and the results show that the proposed method, considering social interactions and social life circle, has better performance than existing recommendation methods.