WorldWideScience

Sample records for reliably assigned patients

  1. A method to assign failure rates for piping reliability assessments

    International Nuclear Information System (INIS)

    Gamble, R.M.; Tagart, S.W. Jr.

    1991-01-01

    This paper reports on a simplified method that has been developed to assign failure rates that can be used in reliability and risk studies of piping. The method can be applied on a line-by-line basis by identifying line and location specific attributes that can lead to piping unreliability from in-service degradation mechanisms and random events. A survey of service experience for nuclear piping reliability also was performed. The data from this survey provides a basis for identifying in-service failure attributes and assigning failure rates for risk and reliability studies

  2. The Assignment of American Society of Anesthesiologists Physical Status Classification for Adult Polytrauma Patients: Results From a Survey and Future Considerations.

    Science.gov (United States)

    Kuza, Catherine M; Hatzakis, George; Nahmias, Jeffry T

    2017-12-01

    The American Society of Anesthesiologists (ASA) physical status (PS) classification system assesses the preoperative health of patients. Previous studies demonstrated poor interrater reliability and variable ASA PS scores, especially in trauma scenarios. There are few studies that evaluated the assignment of ASA PS scores in trauma patients and no studies that evaluated ASA PS assignment in severely injured adult polytrauma patients. Our objective was to assess interrater reliability and identify sources of discrepancy among anesthesiologists and trauma surgeons in designating ASA PS scores to adult polytrauma patients. A link to an online survey containing questions assessing attitudes regarding ASA PS classification, demographic information, and 8 fictional trauma cases was e-mailed to anesthesiologists and trauma surgeons. The participants were asked to assign an ASA PS score to each scenario and explain their choice. Rater-versus-reference and interrater reliability, beyond that expected by chance, among respondents was analyzed using the Fleiss kappa analysis. A total of 349 participants completed the survey. All 8 cases had inconsistent ASA PS scores; several cases had scores ranging from I to VI and variable emergency (E) designations. Using weighted kappa (Kw) analysis for a subset of 201 respondents (101 trauma surgeons [S] and 100 anesthesiologists [A]), we found moderate (Kw = 0.63; SE = 0.024; 95% confidence interval, 0.594-0.666; P polytrauma patients. Although the ASA PS is used in some trauma risk stratification models, discrepancies of ASA PS scores assigned to trauma cases exist. Future modifications of the ASA PS guidelines should aim to improve the interrater reliability of ASA PS scores in trauma patients. Further studies are warranted to determine the value of the ASA PS score as a trauma prognostic metric.

  3. Rate Adaptive Selective Segment Assignment for Reliable Wireless Video Transmission

    Directory of Open Access Journals (Sweden)

    Sajid Nazir

    2012-01-01

    Full Text Available A reliable video communication system is proposed based on data partitioning feature of H.264/AVC, used to create a layered stream, and LT codes for erasure protection. The proposed scheme termed rate adaptive selective segment assignment (RASSA is an adaptive low-complexity solution to varying channel conditions. The comparison of the results of the proposed scheme is also provided for slice-partitioned H.264/AVC data. Simulation results show competitiveness of the proposed scheme compared to optimized unequal and equal error protection solutions. The simulation results also demonstrate that a high visual quality video transmission can be maintained despite the adverse effect of varying channel conditions and the number of decoding failures can be reduced.

  4. A generic method for assignment of reliability scores applied to solvent accessibility predictions

    Directory of Open Access Journals (Sweden)

    Nielsen Morten

    2009-07-01

    Full Text Available Abstract Background Estimation of the reliability of specific real value predictions is nontrivial and the efficacy of this is often questionable. It is important to know if you can trust a given prediction and therefore the best methods associate a prediction with a reliability score or index. For discrete qualitative predictions, the reliability is conventionally estimated as the difference between output scores of selected classes. Such an approach is not feasible for methods that predict a biological feature as a single real value rather than a classification. As a solution to this challenge, we have implemented a method that predicts the relative surface accessibility of an amino acid and simultaneously predicts the reliability for each prediction, in the form of a Z-score. Results An ensemble of artificial neural networks has been trained on a set of experimentally solved protein structures to predict the relative exposure of the amino acids. The method assigns a reliability score to each surface accessibility prediction as an inherent part of the training process. This is in contrast to the most commonly used procedures where reliabilities are obtained by post-processing the output. Conclusion The performance of the neural networks was evaluated on a commonly used set of sequences known as the CB513 set. An overall Pearson's correlation coefficient of 0.72 was obtained, which is comparable to the performance of the currently best public available method, Real-SPINE. Both methods associate a reliability score with the individual predictions. However, our implementation of reliability scores in the form of a Z-score is shown to be the more informative measure for discriminating good predictions from bad ones in the entire range from completely buried to fully exposed amino acids. This is evident when comparing the Pearson's correlation coefficient for the upper 20% of predictions sorted according to reliability. For this subset, values of 0

  5. Sexism in Language: Do Fiction Writers Assign Agentive and Patient Roles Equally to Male and Female Characters?

    Directory of Open Access Journals (Sweden)

    Dunlop Ochieng

    2012-10-01

    Full Text Available Problem Statement: Studies have shown that language is used discriminatorily to women and men. Hence, there have been movements against gender biased language−the movements which are reported so successful especially in the West.Purpose of Study: This paper however argues that discrimination stems from speakers’ minds; and hence performing gender neutral language alone does not confirm gender neutrality of the performer. The reliable way of judging gender neutrality would then be studying the speakers’ minds.Method: The study applied psychoanalytic literary criticism as a gateway to the unconscious minds of American authors–to find out how gender neutral they were at cognitive level. Through psychoanalytic literary criticism, authors’ suppressed desires would find their way out onto their works in a distorted form. Along these lines, the study assessed the equality in assigning agentive and patient semantic roles between males and females in American fictions–to find out who between males and females were frequently assigned agentive and patient roles of the reciprocal verbs: kiss, hug, marry, and divorce.Findings: The study found out that males were assigned more agentive roles in kiss and hug, and females in divorce. Moreover, both were assigned almost equal roles in marry.Conclusion: The implication of the findings is that speakers’ unconscious mind is basically gender biased along gender stereotypes.

  6. Reliable scar scoring system to assess photographs of burn patients.

    Science.gov (United States)

    Mecott, Gabriel A; Finnerty, Celeste C; Herndon, David N; Al-Mousawi, Ahmed M; Branski, Ludwik K; Hegde, Sachin; Kraft, Robert; Williams, Felicia N; Maldonado, Susana A; Rivero, Haidy G; Rodriguez-Escobar, Noe; Jeschke, Marc G

    2015-12-01

    Several scar-scoring scales exist to clinically monitor burn scar development and maturation. Although scoring scars through direct clinical examination is ideal, scars must sometimes be scored from photographs. No scar scale currently exists for the latter purpose. We modified a previously described scar scale (Yeong et al., J Burn Care Rehabil 1997) and tested the reliability of this new scale in assessing burn scars from photographs. The new scale consisted of three parameters as follows: scar height, surface appearance, and color mismatch. Each parameter was assigned a score of 1 (best) to 4 (worst), generating a total score of 3-12. Five physicians with burns training scored 120 representative photographs using the original and modified scales. Reliability was analyzed using coefficient of agreement, Cronbach alpha, intraclass correlation coefficient, variance, and coefficient of variance. Analysis of variance was performed using the Kruskal-Wallis test. Color mismatch and scar height scores were validated by analyzing actual height and color differences. The intraclass correlation coefficient, the coefficient of agreement, and Cronbach alpha were higher for the modified scale than those of the original scale. The original scale produced more variance than that in the modified scale. Subanalysis demonstrated that, for all categories, the modified scale had greater correlation and reliability than the original scale. The correlation between color mismatch scores and actual color differences was 0.84 and between scar height scores and actual height was 0.81. The modified scar scale is a simple, reliable, and useful scale for evaluating photographs of burn patients. Copyright © 2015 Elsevier Inc. All rights reserved.

  7. The reliability of alcoholism history in patients with alcohol-related cirrhosis.

    Science.gov (United States)

    Yates, W R; Labrecque, D R; Pfab, D

    1998-01-01

    Alcoholic liver disease is considered an indication for liver transplantation when a candidate is felt to have a high likelihood of abstinence following transplantation. Historical variables such as duration of sobriety, duration and quantity of drinking, and treatment history are commonly used to estimate alcoholism prognosis, yet their reliability and validity in patients with alcoholic cirrhosis has received limited study. Fifty subjects (9 women and 41 men) with alcoholic cirrhosis underwent an alcoholism history interview. Each subject had a collateral source (usually a spouse) who was interviewed by a second interviewer blind to the subject's alcoholism history. The two histories were compared for duration of abstinence in months and estimated alcoholism relapse risk was calculated using the High-risk Alcoholism Relapse scale (HRAR). Duration of sobriety correlated highly between subject and collateral source (Spearman r= 0.96, P = 0.0001) as did HRAR total score (Spearman r = 0.72, P = 0.0001). Categorical assignments also showed high correlations with duration of sobriety (kappa = 0.97) and HRAR category (kappa = 0.63). When disagreements were present, collateral sources tended to underestimate severity of alcoholism. We conclude that patients with alcoholic liver disease provide a reliable history for alcoholism variables when compared with a collateral source, and that, when disagreements are present, subjects tend to report a more acute or severe alcohol problem. The results support the clinical use of patient history information in making decisions about medical interventions for alcoholic liver disease.

  8. 76 FR 16240 - Mandatory Reliability Standards for Interconnection Reliability Operating Limits

    Science.gov (United States)

    2011-03-23

    ... identified by the Commission. \\5\\ Mandatory Reliability Standards for the Bulk-Power System, Order No. 693... reliability of the interconnection by ensuring that the bulk electric system is assessed during the operations... responsibility for SOLs. Further, Bulk-Power System reliability practices assign responsibilities for analyzing...

  9. Interface Assignment-Based AODV Routing Protocol to Improve Reliability in Multi-Interface Multichannel Wireless Mesh Networks

    Directory of Open Access Journals (Sweden)

    Won-Suk Kim

    2015-01-01

    Full Text Available The utilization of wireless mesh networks (WMNs has greatly increased, and the multi-interface multichannel (MIMC technic has been widely used for the backbone network. Unfortunately, the ad hoc on-demand distance vector (AODV routing protocol defined in the IEEE 802.11s standard was designed for WMNs using the single-interface single-channel technic. So, we define a problem that happens when the legacy AODV is used in MIMC WMNs and propose an interface assignment-based AODV (IA-AODV in order to resolve that problem. IA-AODV, which is based on multitarget path request, consists of the PREQ prediction scheme, the PREQ loss recovery scheme, and the PREQ sender assignment scheme. A detailed operation according to various network conditions and services is introduced, and the routing efficiency and network reliability of a network using IA-AODV are analyzed over the presented system model. Finally, after a real-world test-bed for MIMC WMNs using the IA-AODV routing protocol is implemented, the various indicators of the network are evaluated through experiments. When the proposed routing protocol is compared with the existing AODV routing protocol, it performs the path update using only 14.33% of the management frames, completely removes the routing malfunction, and reduces the UDP packet loss ratio by 0.0012%.

  10. Probabilistic validation of protein NMR chemical shift assignments

    International Nuclear Information System (INIS)

    Dashti, Hesam; Tonelli, Marco; Lee, Woonghee; Westler, William M.; Cornilescu, Gabriel; Ulrich, Eldon L.; Markley, John L.

    2016-01-01

    Data validation plays an important role in ensuring the reliability and reproducibility of studies. NMR investigations of the functional properties, dynamics, chemical kinetics, and structures of proteins depend critically on the correctness of chemical shift assignments. We present a novel probabilistic method named ARECA for validating chemical shift assignments that relies on the nuclear Overhauser effect data. ARECA has been evaluated through its application to 26 case studies and has been shown to be complementary to, and usually more reliable than, approaches based on chemical shift databases. ARECA is available online at http://areca.nmrfam.wisc.edu/ http://areca.nmrfam.wisc.edu/

  11. Probabilistic validation of protein NMR chemical shift assignments

    Energy Technology Data Exchange (ETDEWEB)

    Dashti, Hesam [University of Wisconsin-Madison, Graduate Program in Biophysics, Biochemistry Department (United States); Tonelli, Marco; Lee, Woonghee; Westler, William M.; Cornilescu, Gabriel [University of Wisconsin-Madison, Biochemistry Department, National Magnetic Resonance Facility at Madison (United States); Ulrich, Eldon L. [University of Wisconsin-Madison, BioMagResBank, Biochemistry Department (United States); Markley, John L., E-mail: markley@nmrfam.wisc.edu, E-mail: jmarkley@wisc.edu [University of Wisconsin-Madison, Biochemistry Department, National Magnetic Resonance Facility at Madison (United States)

    2016-01-15

    Data validation plays an important role in ensuring the reliability and reproducibility of studies. NMR investigations of the functional properties, dynamics, chemical kinetics, and structures of proteins depend critically on the correctness of chemical shift assignments. We present a novel probabilistic method named ARECA for validating chemical shift assignments that relies on the nuclear Overhauser effect data. ARECA has been evaluated through its application to 26 case studies and has been shown to be complementary to, and usually more reliable than, approaches based on chemical shift databases. ARECA is available online at http://areca.nmrfam.wisc.edu/ http://areca.nmrfam.wisc.edu/.

  12. Improving patient safety: patient-focused, high-reliability team training.

    Science.gov (United States)

    McKeon, Leslie M; Cunningham, Patricia D; Oswaks, Jill S Detty

    2009-01-01

    Healthcare systems are recognizing "human factor" flaws that result in adverse outcomes. Nurses work around system failures, although increasing healthcare complexity makes this harder to do without risk of error. Aviation and military organizations achieve ultrasafe outcomes through high-reliability practice. We describe how reliability principles were used to teach nurses to improve patient safety at the front line of care. Outcomes include safety-oriented, teamwork communication competency; reflections on safety culture and clinical leadership are discussed.

  13. Reliability of maximal isometric knee strength testing with modified hand-held dynamometry in patients awaiting total knee arthroplasty: useful in research and individual patient settings? A reliability study

    Directory of Open Access Journals (Sweden)

    Koblbauer Ian FH

    2011-10-01

    Full Text Available Abstract Background Patients undergoing total knee arthroplasty (TKA often experience strength deficits both pre- and post-operatively. As these deficits may have a direct impact on functional recovery, strength assessment should be performed in this patient population. For these assessments, reliable measurements should be used. This study aimed to determine the inter- and intrarater reliability of hand-held dynamometry (HHD in measuring isometric knee strength in patients awaiting TKA. Methods To determine interrater reliability, 32 patients (81.3% female were assessed by two examiners. Patients were assessed consecutively by both examiners on the same individual test dates. To determine intrarater reliability, a subgroup (n = 13 was again assessed by the examiners within four weeks of the initial testing procedure. Maximal isometric knee flexor and extensor strength were tested using a modified Citec hand-held dynamometer. Both the affected and unaffected knee were tested. Reliability was assessed using the Intraclass Correlation Coefficient (ICC. In addition, the Standard Error of Measurement (SEM and the Smallest Detectable Difference (SDD were used to determine reliability. Results In both the affected and unaffected knee, the inter- and intrarater reliability were good for knee flexors (ICC range 0.76-0.94 and excellent for knee extensors (ICC range 0.92-0.97. However, measurement error was high, displaying SDD ranges between 21.7% and 36.2% for interrater reliability and between 19.0% and 57.5% for intrarater reliability. Overall, measurement error was higher for the knee flexors than for the knee extensors. Conclusions Modified HHD appears to be a reliable strength measure, producing good to excellent ICC values for both inter- and intrarater reliability in a group of TKA patients. High SEM and SDD values, however, indicate high measurement error for individual measures. This study demonstrates that a modified HHD is appropriate to

  14. Using HL7 in hospital staff assignments.

    Science.gov (United States)

    Unluturk, Mehmet S

    2014-02-01

    Hospital staff assignments are the instructions that allocate the hospital staff members to the hospital beds. Currently, hospital administrators make the assignments without accessing the information regarding the occupancy of the hospital beds and the acuity of the patient. As a result, administrators cannot distinguish between occupied and unoccupied beds, and may therefore assign staff to unoccupied beds. This gives rise to uneven and inefficient staff assignments. In this paper, the hospital admission-discharge-transfer (ADT) system is employed both as a data source and an assignment device to create staff assignments. When the patient data is newly added or modified, the ADT system updates the assignment software client with the relevant data. Based on the relevant data, the assignment software client is able to construct staff assignments in a more efficient way. © 2013 Elsevier Ltd. All rights reserved.

  15. Remote patient monitoring: Information reliability challenges

    NARCIS (Netherlands)

    Petkovic, M.

    2009-01-01

    An increasing number of extramural applications in the personal healthcare domain pose new challenges regarding the security of medical data. In this paper, we focus on remote patient monitoring systems and the issues around information reliability. In these systems medical data is not collected by

  16. Reliability of patient-reported outcomes in rheumatoid arthritis patients: an observational prospective study.

    Science.gov (United States)

    Studenic, Paul; Stamm, Tanja; Smolen, Josef S; Aletaha, Daniel

    2016-01-01

    Patient-reported outcomes (PROs) such as pain, patient global assessment (PGA) and fatigue are regularly assessed in RA patients. In the present study, we aimed to explore the reliability and smallest detectable differences (SDDs) of these PROs, and whether the time between assessments has an impact on reliability. Forty RA patients on stable treatment reported the three PROs daily over two subsequent months. We assessed the reliability of these measures by calculating intraclass correlation coefficients (ICCs) and the SDDs for 1-, 7-, 14- and 28-day test-retest intervals. Overall, SDD and ICC were 25 mm and 0.67 for pain, 25 mm and 0.71 for PGA and 30 mm and 0.66 for fatigue, respectively. SDD was higher with longer time period between assessments, ranging from 19 mm (1-day intervals) to 30 mm (28-day intervals) for pain, 19 to 33 mm for PGA, and 26 to 34 mm for fatigue; correspondingly, ICC was smaller with longer intervals, and ranged between the 1- and the 28-day interval from 0.80 to 0.50 for pain, 0.83 to 0.57 for PGA and 0.76 to 0.58 for fatigue. The baseline simplified disease activity index did not have any influence on reliability. Lower baseline PRO scores led to smaller SDDs. Reliability of pain, PGA and fatigue measurements is dependent on the tested time interval and the baseline levels. The relatively high SDDs, even for patients in the lowest tertiles of their PROs, indicate potential issues for assessment of the presence of remission. © The Author 2015. Published by Oxford University Press on behalf of the British Society for Rheumatology. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  17. Review of Outcome Information in 46,XX Patients with Congenital Adrenal Hyperplasia Assigned/Reared Male: What Does It Say about Gender Assignment?

    Directory of Open Access Journals (Sweden)

    Lee PeterA

    2010-12-01

    Full Text Available There is ample historical verification of 46,XX congenital adrenal hyperplasia (CAH patients being born with essentially male genitaliawhile outcome information is scant. Prior to glucocorticoid therapy, most patients died very young from adrenal insufficiency. Most available reports from laterchildhood, contain little information concerning sexual identity. Reports on older individuals lack adequate information about sexual identity and quality of life. The difficulty in assessing the relative impact of multiple dynamic environmental factors on the development of sexual identity, self- and body esteem and overall adjustment to life is clear. Nevertheless, it remains unclear whether those infants whose masculine genitalia at birth resulted in an initial male assignment would have enjoyed a better adult outcome had they been allowed to remain male rather than the female reassignment that most received. Further, one could ask whether a male sex of rearing should be considered in 46,XX CAH infants with male external genitalia. After reviewing available literature, we conclude that because those extremely virlized 46,XX CAH patients who were reared male with healthy social support demonstrated satisfactory levels of social and sexual function as adults a male sex assignment should be considered in these types of infants when social and cultural environment are supportive.

  18. [Creating a reliable therapeutic relationship with the patient].

    Science.gov (United States)

    Matsuki, Kunihiro

    2012-01-01

    The factors necessary to create a reliable therapeutic relationship are presented in this paper. They include a demeanor and calmness of temperament as a psychiatric professional, a feeling of respect for the patient that is based on our common sense as human beings, an attitude of listening attentively to what the patient is revealing, maintaining an attitude of receptive neutrality, the ability to withstand the emotional burdens imposed on one by the patient, patience with any difficulty on one's own part to understand the patient, the ability to communicate clearly, including on the patient's negative aspects, and the ability to end psychiatric consultation sessions in a friendly and intimate manner. Creating a beneficial therapeutic relationship is about the building of a trusting relationship, in which the patient can constructively endure being questioned by us, or cope with the tough burdens we may place on them. However, a reliable relationship such as this contains paradoxes. Patients are able to talk to us about their suspicions, anxieties, dissatisfactions or anger only if the therapeutic relationship is good or based on trust. In other words, just like our patients, psychiatrists, too, must deal with what that the patient brings and directs toward us. It is at this point that what we call a true therapeutic relationship starts.

  19. Reliability of the ECHOWS Tool for Assessment of Patient Interviewing Skills.

    Science.gov (United States)

    Boissonnault, Jill S; Evans, Kerrie; Tuttle, Neil; Hetzel, Scott J; Boissonnault, William G

    2016-04-01

    History taking is an important component of patient/client management. Assessment of student history-taking competency can be achieved via a standardized tool. The ECHOWS tool has been shown to be valid with modest intrarater reliability in a previous study but did not demonstrate sufficient power to definitively prove its stability. The purposes of this study were: (1) to assess the reliability of the ECHOWS tool for student assessment of patient interviewing skills and (2) to determine whether the tool discerns between novice and experienced skill levels. A reliability and construct validity assessment was conducted. Three faculty members from the United States and Australia scored videotaped histories from standardized patients taken by students and experienced clinicians from each of these countries. The tapes were scored twice, 3 to 6 weeks apart. Reliability was assessed using interclass correlation coefficients (ICCs) and repeated measures. Analysis of variance models assessed the ability of the tool to discern between novice and experienced skill levels. The ECHOWS tool showed excellent intrarater reliability (ICC [3,1]=.74-.89) and good interrater reliability (ICC [2,1]=.55) as a whole. The summary of performance (S) section showed poor interrater reliability (ICC [2,1]=.27). There was no statistical difference in performance on the tool between novice and experienced clinicians. A possible ceiling effect may occur when standardized patients are not coached to provide complex and obtuse responses to interviewer questions. Variation in familiarity with the ECHOWS tool and in use of the online training may have influenced scoring of the S section. The ECHOWS tool demonstrates excellent intrarater reliability and moderate interrater reliability. Sufficient training with the tool prior to student assessment is recommended. The S section must evolve in order to provide a more discerning measure of interviewing skills. © 2016 American Physical Therapy

  20. 75 FR 71613 - Mandatory Reliability Standards for Interconnection Reliability Operating Limits

    Science.gov (United States)

    2010-11-24

    ... Interconnection to relieve overloads on the facilities modeled in the Interchange Distribution Calculator (IDC... for other SOLs. But the Functional Model assigns a much broader role to the reliability coordinator to...

  1. Reliability of in-Shoe Plantar Pressure Measurements in Rheumatoid Arthritis Patients

    Science.gov (United States)

    Vidmar, Gaj; Novak, Primoz

    2009-01-01

    Plantar pressures measurement is a frequently used method in rehabilitation and related research. Metric characteristics of the F-Scan system have been assessed from different standpoints and in different patients, but not its reliability in rheumatoid arthritis patients. Therefore, our objective was to assess reliability of the F-Scan plantar…

  2. EZ-ASSIGN, a program for exhaustive NMR chemical shift assignments of large proteins from complete or incomplete triple-resonance data

    Energy Technology Data Exchange (ETDEWEB)

    Zuiderweg, Erik R. P., E-mail: zuiderwe@umich.edu; Bagai, Ireena [The University of Michigan Medical School, Department of Biological Chemistry (United States); Rossi, Paolo [Rutgers University, Center for Integrative Proteomics Research (United States); Bertelsen, Eric B. [Arbor Communications, Inc. (United States)

    2013-10-15

    For several of the proteins in the BioMagResBank larger than 200 residues, 60 % or fewer of the backbone resonances were assigned. But how reliable are those assignments? In contrast to complete assignments, where it is possible to check whether every triple-resonance Generalized Spin System (GSS) is assigned once and only once, with incomplete data one should compare all possible assignments and pick the best one. But that is not feasible: For example, for 200 residues and an incomplete set of 100 GSS, there are 1.6 Multiplication-Sign 10{sup 260} possible assignments. In 'EZ-ASSIGN', the protein sequence is divided in smaller unique fragments. Combined with intelligent search approaches, an exhaustive comparison of all possible assignments is now feasible using a laptop computer. The program was tested with experimental data of a 388-residue domain of the Hsp70 chaperone protein DnaK and for a 351-residue domain of a type III secretion ATPase. EZ-ASSIGN reproduced the hand assignments. It did slightly better than the computer program PINE (Bahrami et al. in PLoS Comput Biol 5(3):e1000307, 2009) and significantly outperformed SAGA (Crippen et al. in J Biomol NMR 46:281-298, 2010), AUTOASSIGN (Zimmerman et al. in J Mol Biol 269:592-610, 1997), and IBIS (Hyberts and Wagner in J Biomol NMR 26:335-344, 2003). Next, EZ-ASSIGN was used to investigate how well NMR data of decreasing completeness can be assigned. We found that the program could confidently assign fragments in very incomplete data. Here, EZ-ASSIGN dramatically outperformed all the other assignment programs tested.

  3. EZ-ASSIGN, a program for exhaustive NMR chemical shift assignments of large proteins from complete or incomplete triple-resonance data

    International Nuclear Information System (INIS)

    Zuiderweg, Erik R. P.; Bagai, Ireena; Rossi, Paolo; Bertelsen, Eric B.

    2013-01-01

    For several of the proteins in the BioMagResBank larger than 200 residues, 60 % or fewer of the backbone resonances were assigned. But how reliable are those assignments? In contrast to complete assignments, where it is possible to check whether every triple-resonance Generalized Spin System (GSS) is assigned once and only once, with incomplete data one should compare all possible assignments and pick the best one. But that is not feasible: For example, for 200 residues and an incomplete set of 100 GSS, there are 1.6 × 10 260 possible assignments. In “EZ-ASSIGN”, the protein sequence is divided in smaller unique fragments. Combined with intelligent search approaches, an exhaustive comparison of all possible assignments is now feasible using a laptop computer. The program was tested with experimental data of a 388-residue domain of the Hsp70 chaperone protein DnaK and for a 351-residue domain of a type III secretion ATPase. EZ-ASSIGN reproduced the hand assignments. It did slightly better than the computer program PINE (Bahrami et al. in PLoS Comput Biol 5(3):e1000307, 2009) and significantly outperformed SAGA (Crippen et al. in J Biomol NMR 46:281–298, 2010), AUTOASSIGN (Zimmerman et al. in J Mol Biol 269:592–610, 1997), and IBIS (Hyberts and Wagner in J Biomol NMR 26:335–344, 2003). Next, EZ-ASSIGN was used to investigate how well NMR data of decreasing completeness can be assigned. We found that the program could confidently assign fragments in very incomplete data. Here, EZ-ASSIGN dramatically outperformed all the other assignment programs tested

  4. Validity evidence and reliability of a simulated patient feedback instrument.

    Science.gov (United States)

    Schlegel, Claudia; Woermann, Ulrich; Rethans, Jan-Joost; van der Vleuten, Cees

    2012-01-27

    In the training of healthcare professionals, one of the advantages of communication training with simulated patients (SPs) is the SP's ability to provide direct feedback to students after a simulated clinical encounter. The quality of SP feedback must be monitored, especially because it is well known that feedback can have a profound effect on student performance. Due to the current lack of valid and reliable instruments to assess the quality of SP feedback, our study examined the validity and reliability of one potential instrument, the 'modified Quality of Simulated Patient Feedback Form' (mQSF). Content validity of the mQSF was assessed by inviting experts in the area of simulated clinical encounters to rate the importance of the mQSF items. Moreover, generalizability theory was used to examine the reliability of the mQSF. Our data came from videotapes of clinical encounters between six simulated patients and six students and the ensuing feedback from the SPs to the students. Ten faculty members judged the SP feedback according to the items on the mQSF. Three weeks later, this procedure was repeated with the same faculty members and recordings. All but two items of the mQSF received importance ratings of > 2.5 on a four-point rating scale. A generalizability coefficient of 0.77 was established with two judges observing one encounter. The findings for content validity and reliability with two judges suggest that the mQSF is a valid and reliable instrument to assess the quality of feedback provided by simulated patients.

  5. Inter-rater reliability of the Sødring Motor Evaluation of Stroke patients (SMES).

    Science.gov (United States)

    Halsaa, K E; Sødring, K M; Bjelland, E; Finsrud, K; Bautz-Holter, E

    1999-12-01

    The Sødring Motor Evaluation of Stroke patients is an instrument for physiotherapists to evaluate motor function and activities in stroke patients. The rating reflects quality as well as quantity of the patient's unassisted performance within three domains: leg, arm and gross function. The inter-rater reliability of the method was studied in a sample of 30 patients admitted to a stroke rehabilitation unit. Three therapists were involved in the study; two therapists assessed the same patient on two consecutive days in a balanced design. Cohen's weighted kappa and McNemar's test of symmetry were used as measures of item reliability, and the intraclass correlation coefficient was used to express the reliability of the sumscores. For 24 out of 32 items the weighted kappa statistic was excellent (0.75-0.98), while 7 items had a kappa statistic within the range 0.53-0.74 (fair to good). The reliability of one item was poor (0.13). The intraclass correlation coefficient for the three sumscores was 0.97, 0.91 and 0.97. We conclude that the Sødring Motor Evaluation of Stroke patients is a reliable measure of motor function in stroke patients undergoing rehabilitation.

  6. Is the Frontal Assessment Battery reliable in ALS patients?

    NARCIS (Netherlands)

    Raaphorst, J.; Beeldman, E.; Jaeger, B.; Schmand, B.A.; Berg, L.H. van den; Weikamp, J.G.; Schelhaas, H.J.; Visser, M. de; Haan, R.J. de

    2013-01-01

    The assessment of frontal functions in ALS patients is important because of the overlap with the behavioural variant of frontotemporal dementia (bvFTD). We investigated the applicability and reliability of the Frontal Assessment Battery (FAB) within a cohort of predominantly prevalent ALS patients.

  7. Reliability of proxy respondents for patients with stroke: a systematic review.

    Science.gov (United States)

    Oczkowski, Colin; O'Donnell, Martin

    2010-01-01

    Proxy respondents are an important aspect of stroke medicine and research. We performed a systematic review of studies evaluating the reliability of proxy respondents for stroke patients. Studies were identified by searches of MEDLINE, Google, and the Cochrane Library between January 1969 and June 2008. All were prospective or cross-sectional studies reporting the reliability of proxy respondents for patients with a history of previous stroke or transient ischemic attack. One author abstracted data. For each study, intraclass correlation (ICC) or the k-statistic was categorized as poor (0.80). Thirteen studies, with a total of 2618 participants, met our inclusion criteria. Most studies recruited patients >3 months after their stroke. Of these studies, 5 (360 participants; 5 scales) evaluated reliability of proxy respondents for activities of daily living (ADL), and 9 (2334 participants; 9 scales) evaluated reliability of proxy respondents for quality of life (QoL). One study evaluated both. In studies, the ICC/k for scales ranged from 0.61 to 0.91 for ADL and from 0.41 to 0.8 for QoL. Most studies reported that proxy respondents overestimated impairments compared with patient self-reports. Stroke severity and objective nature of questions were the most consistent determinants of disagreement between stroke patient and proxy respondent. Our data indicate that beyond the acute stroke period, the reliability of proxy respondents for validated scales of ADL was substantial to excellent, while that of scales for QoL was moderate to substantial. Copyright (c) 2010 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  8. A Joint Link and Channel Assignment Routing Scheme for Cognitive Radio Networks

    Directory of Open Access Journals (Sweden)

    H.S.Zhao

    2013-12-01

    Full Text Available Cognitive radio (CR is a promising technology that enables opportunistic utilization of the temporarily vacant spectrum to mitigate the spectrum scarcity in wireless communications. Since secondary users (SUs should vacate the channel in use immediately after detecting the reappearances of primary users (PUs in cognitive radio networks (CRNs, the route reliability is a distinctive challenge for routing in CRNs. Furthermore, the throughput requirement of an SU session should be satisfied and it is always preferable to select a route with less negative influence on other current or latish sessions. To account for the route reliability challenge, we study the joint link and channel assignment routing problem for CRNs. It is formulated in a form of integer nonlinear programming (INLP, which is NP-hard, with the objective of minimizing the interference of a new route to other routes while providing route reliability and throughput guarantee. An on-demand route discovery algorithm is proposed to find reliable candidate paths, while a joint link and channel assignment routing algorithm with sequentially-connected-link coordination is proposed to choose the near-optimal route for improving the route reliability and minimizing negative influence. Simulation results demonstrate that the proposed algorithm achieves considerable improvement over existing schemes in both route reliability and throughput.

  9. Reliability of scored patient generated subjective global assessment ...

    African Journals Online (AJOL)

    Objective: Establish the reliability of the scored Patient Generated-Subjective Global Assessment (PG-SGA) in determining nutritional status among Antiretroviral Therapy (ART) naive HIV-infected adults. Methods: A descriptive, cross sectional study among outpatient medical clinics, in The AIDS Support Organization ...

  10. Triage level assignment and nurse characteristics and experience.

    Science.gov (United States)

    Gómez-Angelats, Elisenda; Miró, Òscar; Bragulat Baur, Ernesto; Antolín Santaliestra, Alberto; Sánchez Sánchez, Miquel

    2018-06-01

    To study the relation between nursing staff demographics and experience and their assignment of triage level in the emergency department. One-year retrospective observational study in the triage area of a tertiary care urban university hospital that applies the Andorran-Spanish triage model. Variables studied were age, gender, nursing experience, triage experience, shift, usual level of emergency work the nurse undertakes, number of triage decisions made, and percentage of patients assigned to each level. Fifty nurses (5 men, 45 women) with a mean (SD) age of 45 (9) years triaged 67 803 patients during the year. Nurses classified more patients in level 5 on the morning shift (7.9%) than on the afternoon shift (5.5%) (P=.003). The difference in the rate of level-5 triage classification became significant when nurses were older (β = 0.092, P=.037) and experience was greater (β = 0.103, P=.017). The number of triages recorded by a nurse was significantly and directly related to the percentage of patients assigned to level 3 (β = 0.003, P=.006) and inversely related to the percentages assigned to level 4 (β = -0.002, P=.008) and level 5 (β = -0.001, P=.017). We found that triage level assignments were related to age, experience, shift, and total number of patients triaged by a nurse.

  11. Validity and reliability of short form-12 questionnaire in Iranian hemodialysis patients

    DEFF Research Database (Denmark)

    Pakpour, Amir H.; Nourozi, Saeedeh; Mølsted, Stig

    2011-01-01

    INTRODUCTION: The aim of the study was to assess the validity and reliability of the SF-12 questionnaire in a sample of Iranian patients undergoing hemodialysis. MATERIALS AND METHODS: One hundred and forty-four hemodialysis patients were included from dialysis centers in Zanjan, Iran, and were...... asked to complete the SF-12 and SF-36 questionnaires. An initial test-retest reliability evaluation was performed on a sample of 70 patients from the total group, with a retest interval of 14 days. Reliability was estimated by internal consistency and validity was assessed using known-group comparisons...... and construct validity on the patient group as a whole. A linear regression analysis was used to assess any variation in the physical component summary and mental component summary scores of the SF-36 with the respective component summary scores of the SF-12. In addition, the factor structure...

  12. Inter- and intrarater reliability of goniometry and hand held dynamometry for patients with subacromial impingement syndrome.

    Science.gov (United States)

    Fieseler, Georg; Laudner, Kevin G; Irlenbusch, Lars; Meyer, Henrike; Schulze, Stephan; Delank, Karl-Stefan; Hermassi, Souhail; Bartels, Thomas; Schwesig, René

    2017-12-01

    The purpose of this study was to examine the intra- and interrater reliability of measuring shoulder range of motion (ROM) and strength among patients diagnosed with subacromial impingement syndrome (SAIS). Twenty-five patients (14 female patients; mean age, 60.4± 7.84 years) diagnosed with SAIS were assessed to determine the intrarater reliability for glenohumeral ROM. Twenty-five patients (16 female patients; mean age, 60.4± 7.80 years) and 76 asymptomatic volunteers (52 female volunteers; mean age, 29.4± 14.1 years) were assessed for interrater reliability. Dependent variables were active shoulder ROM and isometric strength. Intrarater reliability was fair-to-excellent for the SAIS patients (intraclass correlation coefficient [ICC], 0.52-0.97; standard error of measurement [SEM], 4.4°-9.9° N; coefficient of variation [CV], 7.1%-44.9%). Based on the ICC, 11 of 12 parameters (92%) displayed an excellent reliability (ICC> 0.75). The interrater reliability showed fair-to-excellent results (SAIS patients: ICC, 0.13-0.98; SEM, 2.3°-8.8°; CV, 3.6%-37.0%; controls: ICC, 0.11-0.96; SEM, 3.0°-35.4°; CV, 5.6%-26.4%). In accordance with the intrarater reliability, glenohumeral adduction ROM was the only parameter with an ICC below 0.75 for both samples. Painful shoulder ROM in the SAIS patients showed no influence on the quality of reliability for measurement. Therefore, these protocols should be considered reliable assessment techniques in the prevention, diagnosis, and treatment of painful shoulder conditions such as SAIS.

  13. A reliable transmission protocol for ZigBee-based wireless patient monitoring.

    Science.gov (United States)

    Chen, Shyr-Kuen; Kao, Tsair; Chan, Chia-Tai; Huang, Chih-Ning; Chiang, Chih-Yen; Lai, Chin-Yu; Tung, Tse-Hua; Wang, Pi-Chung

    2012-01-01

    Patient monitoring systems are gaining their importance as the fast-growing global elderly population increases demands for caretaking. These systems use wireless technologies to transmit vital signs for medical evaluation. In a multihop ZigBee network, the existing systems usually use broadcast or multicast schemes to increase the reliability of signals transmission; however, both the schemes lead to significantly higher network traffic and end-to-end transmission delay. In this paper, we present a reliable transmission protocol based on anycast routing for wireless patient monitoring. Our scheme automatically selects the closest data receiver in an anycast group as a destination to reduce the transmission latency as well as the control overhead. The new protocol also shortens the latency of path recovery by initiating route recovery from the intermediate routers of the original path. On the basis of a reliable transmission scheme, we implement a ZigBee device for fall monitoring, which integrates fall detection, indoor positioning, and ECG monitoring. When the triaxial accelerometer of the device detects a fall, the current position of the patient is transmitted to an emergency center through a ZigBee network. In order to clarify the situation of the fallen patient, 4-s ECG signals are also transmitted. Our transmission scheme ensures the successful transmission of these critical messages. The experimental results show that our scheme is fast and reliable. We also demonstrate that our devices can seamlessly integrate with the next generation technology of wireless wide area network, worldwide interoperability for microwave access, to achieve real-time patient monitoring.

  14. Reliability of diabetic patients' gait parameters in a challenging environment.

    Science.gov (United States)

    Allet, L; Armand, S; de Bie, R A; Golay, A; Monnin, D; Aminian, K; de Bruin, E D

    2008-11-01

    Activities of daily life require us to move about in challenging environments and to walk on varied surfaces. Irregular terrain has been shown to influence gait parameters, especially in a population at risk for falling. A precise portable measurement system would permit objective gait analysis under such conditions. The aims of this study are to (a) investigate the reliability of gait parameters measured with the Physilog in diabetic patients walking on different surfaces (tar, grass, and stones); (b) identify the measurement error (precision); (c) identify the minimal clinical detectable change. 16 patients with Type 2 diabetes were measured twice within 8 days. After clinical examination patients walked, equipped with a Physilog, on the three aforementioned surfaces. ICC for each surface was excellent for within-visit analyses (>0.938). Inter-visit ICC's (0.753) were excellent except for the knee range parameter (>0.503). The coefficient of variation (CV) was lower than 5% for most of the parameters. Bland and Altman Plots, SEM and SDC showed precise values, distributed around zero for all surfaces. Good reliability of Physilog measurements on different surfaces suggests that Physilog could facilitate the study of diabetic patients' gait in conditions close to real-life situations. Gait parameters during complex locomotor activities (e.g. stair-climbing, curbs, slopes) have not yet been extensively investigated. Good reliability, small measurement error and values of minimal clinical detectable change recommend the utilization of Physilog for the evaluation of gait parameters in diabetic patients.

  15. Reliability and Validity of the Turkish Version of Patient and Observer Scar Assessment Scale in Patients with Burns

    Directory of Open Access Journals (Sweden)

    Ayşe Kabuk

    2017-12-01

    Full Text Available Objective: To evaluation reliability and validity of the Turkish version of Patient and Observer Scar Assessment Scale (POSAS in patients with burns. Methods: This is a methodologically study. Data were collected using POSAS, survey form and plexiglas. Patient Scar Assessment Scale (PSAS was completed by patients (n=53 and Observer Scar Assessment Scale (OSAS was completed by two observers separately. The test-retest was measured applying the scales in 25 patients after two weeks. Data were analyzed by Kruskal-Wallis and Mann-Whitney U test. Content validity was determined using Kaiser-Meyer-Olkin, Barlett’s test and structure validity was performed by explanatory factor analysis (EFA and confirmatory factor analysis (CFA; reliability was evaluated using internal consistency, Cronbach’s alpha and intraclass correlation coefficient (ICC. Results: Factor weights were in appropriate range according to EFA, 6 items single factor structure of the original scale was valid and had high consistency index according to CFA, ICC between the 7th item and the total points was proportional, inner consistency was highly reliable (PSAS a=0.992, OSAS a=0.993, consistency between the observers was high (a=0.952, r=0.909. It was determined OSAS scores increased as the burn degree increased (p<0.05. Conclusion: POSAS was determined to be a valid and reliable scale in patients with burns in the Turkish society.

  16. Reliability of Patient-Led Screening with the Malnutrition Screening Tool: Agreement between Patient and Health Care Professional Scores in the Cancer Care Ambulatory Setting.

    Science.gov (United States)

    Di Bella, Alexandra; Blake, Claire; Young, Adrienne; Pelecanos, Anita; Brown, Teresa

    2018-02-01

    The prevalence of malnutrition in patients with cancer is reported as high as 60% to 80%, and malnutrition is associated with lower survival, reduced response to treatment, and poorer functional status. The Malnutrition Screening Tool (MST) is a validated tool when administered by health care professionals; however, it has not been evaluated for patient-led screening. This study aims to assess the reliability of patient-led MST screening through assessment of inter-rater reliability between patient-led and dietitian-researcher-led screening and intra-rater reliability between an initial and a repeat patient screening. This cross-sectional study included 208 adults attending ambulatory cancer care services in a metropolitan teaching hospital in Queensland, Australia, in October 2016 (n=160 inter-rater reliability; n=48 intra-rater reliability measured in a separate sample). Primary outcome measures were MST risk categories (MST 0-1: not at risk, MST ≥2: at risk) as determined by screening completed by patients and a dietitian-researcher, patient test-retest screening, and patient acceptability. Percent and chance-corrected agreement (Cohen's kappa coefficient, κ) were used to determine agreement between patient-MST and dietitian-MST (inter-rater reliability) and MST completed by patient on admission to unit (patient-MSTA) and MST completed by patient 1 to 3 hours after completion of initial MST (patient-MSTB) (intra-rater reliability). High inter-rater reliability and intra-rater reliability were observed. Agreement between patient-MST and dietitian-MST was 96%, with "almost perfect" chance-adjusted agreement (κ=0.92, 95% CI 0.84 to 0.97). Agreement between repeated patient-MSTA and patient-MSTB was 94%, with "almost perfect" chance-adjusted agreement (κ=0.88, 95% CI 0.71 to 1.00). Based on dietitian-MST, 33% (n=53) of patients were identified as being at risk for malnutrition, and 40% of these reported not seeing a dietitian. Of 156 patients who provided

  17. High inter-tester reliability of the new mobility score in patients with hip fracture

    DEFF Research Database (Denmark)

    Kristensen, M.T.; Bandholm, T.; Foss, N.B.

    2008-01-01

    OBJECTIVE: To assess the inter-tester reliability of the New Mobility Score in patients with acute hip fracture. DESIGN: An inter-tester reliability study. SUBJECTS: Forty-eight consecutive patients with acute hip fracture at a median age of 84 (interquartile range, 76-89) years; 40 admitted from...

  18. Flexible taxonomic assignment of ambiguous sequencing reads

    Directory of Open Access Journals (Sweden)

    Jansson Jesper

    2011-01-01

    Full Text Available Abstract Background To characterize the diversity of bacterial populations in metagenomic studies, sequencing reads need to be accurately assigned to taxonomic units in a given reference taxonomy. Reads that cannot be reliably assigned to a unique leaf in the taxonomy (ambiguous reads are typically assigned to the lowest common ancestor of the set of species that match it. This introduces a potentially severe error in the estimation of bacteria present in the sample due to false positives, since all species in the subtree rooted at the ancestor are implicitly assigned to the read even though many of them may not match it. Results We present a method that maps each read to a node in the taxonomy that minimizes a penalty score while balancing the relevance of precision and recall in the assignment through a parameter q. This mapping can be obtained in time linear in the number of matching sequences, because LCA queries to the reference taxonomy take constant time. When applied to six different metagenomic datasets, our algorithm produces different taxonomic distributions depending on whether coverage or precision is maximized. Including information on the quality of the reads reduces the number of unassigned reads but increases the number of ambiguous reads, stressing the relevance of our method. Finally, two measures of performance are described and results with a set of artificially generated datasets are discussed. Conclusions The assignment strategy of sequencing reads introduced in this paper is a versatile and a quick method to study bacterial communities. The bacterial composition of the analyzed samples can vary significantly depending on how ambiguous reads are assigned depending on the value of the q parameter. Validation of our results in an artificial dataset confirm that a combination of values of q produces the most accurate results.

  19. Evaluation of ideomotor apraxia in patients with stroke: a study of reliability and validity.

    Science.gov (United States)

    Kaya, Kurtulus; Unsal-Delialioglu, Sibel; Kurt, Murat; Altinok, Nermin; Ozel, Sumru

    2006-03-01

    This aim of this study was to determine the reliability and validity of an established ideomotor apraxia test when applied to a Turkish stroke patient population and to healthy controls. The study group comprised 50 patients with right hemiplegia and 36 with left hemiplegia, who had developed the condition as a result of a cerebrovascular accident, and 33 age-matched healthy subjects. The subjects were evaluated for apraxia using an established ideomotor apraxia test. The cut-off value of the test and the reliability coefficient between observers were determined. Apraxia was found in 54% patients with right hemiplegia (most being severe) and in 25% of left hemiplegic patients (most being mild). The apraxia scores for patients with right hemiplegia were found to be significantly lower than for those with left hemiplegia and for healthy subjects. There was no statistically significant difference between patients with left hemiplegia and healthy subjects. It was shown that the ideomotor apraxia test could distinguish apraxic from non-apraxic subjects. The reliability coefficient among observers in the study was high and a reliability study of the ideomotor apraxia test was therefore performed.

  20. The Kinetics of Chirality Assignment in Catalytic Single Walled Carbon Nanotube Growth

    OpenAIRE

    Xu, Ziwei; Yan, Tianying; Ding, Feng

    2014-01-01

    Chirality-selected single-walled carbon nanotubes (SWCNTs) ensure a great potential of building ~1 nm sized electronics. However, the reliable method for chirality-selected SWCNT is still pending. Here we present a theoretical study on the SWCNT's chirality assignment and control during the catalytic growth. This study reveals that the chirality of a SWCNT is determined by the kinetic incorporation of the pentagon formation during SWCNT nucleation. Therefore, chirality is randomly assigned on...

  1. Reliability of histologic assessment in patients with eosinophilic oesophagitis.

    Science.gov (United States)

    Warners, M J; Ambarus, C A; Bredenoord, A J; Verheij, J; Lauwers, G Y; Walsh, J C; Katzka, D A; Nelson, S; van Viegen, T; Furuta, G T; Gupta, S K; Stitt, L; Zou, G; Parker, C E; Shackelton, L M; D Haens, G R; Sandborn, W J; Dellon, E S; Feagan, B G; Collins, M H; Jairath, V; Pai, R K

    2018-04-01

    The validity of the eosinophilic oesophagitis (EoE) histologic scoring system (EoEHSS) has been demonstrated, but only preliminary reliability data exist. Formally assess the reliability of the EoEHSS and additional histologic features. Four expert gastrointestinal pathologists independently reviewed slides from adult patients with EoE (N = 45) twice, in random order, using standardised training materials and scoring conventions for the EoEHSS and additional histologic features agreed upon during a modified Delphi process. Intra- and inter-rater reliability for scoring the EoEHSS, a visual analogue scale (VAS) of overall histopathologic disease severity, and additional histologic features were assessed using intra-class correlation coefficients (ICCs). Almost perfect intra-rater reliability was observed for the composite EoEHSS scores and the VAS. Inter-rater reliability was also almost perfect for the composite EoEHSS scores and substantial for the VAS. Of the EoEHSS items, eosinophilic inflammation was associated with the highest ICC estimates and consistent with almost perfect intra- and inter-rater reliability. With the exception of dyskeratotic epithelial cells and surface epithelial alteration, ICC estimates for the remaining EoEHSS items were above the benchmarks for substantial intra-rater, and moderate inter-rater reliability. Estimation of peak eosinophil count and number of lamina propria eosinophils were associated with the highest ICC estimates among the exploratory items. The composite EoEHSS and most component items are associated with substantial reliability when assessed by central pathologists. Future studies should assess responsiveness of the score to change after a therapeutic intervention to facilitate its use in clinical trials. © 2018 John Wiley & Sons Ltd.

  2. Automated backbone assignment of labeled proteins using the threshold accepting algorithm

    International Nuclear Information System (INIS)

    Leutner, Michael; Gschwind, Ruth M.; Liermann, Jens; Schwarz, Christian; Gemmecker, Gerd; Kessler, Horst

    1998-01-01

    The sequential assignment of backbone resonances is the first step in the structure determination of proteins by heteronuclear NMR. For larger proteins, an assignment strategy based on proton side-chain information is no longer suitable for the use in an automated procedure. Our program PASTA (Protein ASsignment by Threshold Accepting) is therefore designed to partially or fully automate the sequential assignment of proteins, based on the analysis of NMR backbone resonances plus C β information. In order to overcome the problems caused by peak overlap and missing signals in an automated assignment process, PASTA uses threshold accepting, a combinatorial optimization strategy, which is superior to simulated annealing due to generally faster convergence and better solutions. The reliability of this algorithm is shown by reproducing the complete sequential backbone assignment of several proteins from published NMR data. The robustness of the algorithm against misassigned signals, noise, spectral overlap and missing peaks is shown by repeating the assignment with reduced sequential information and increased chemical shift tolerances. The performance of the program on real data is finally demonstrated with automatically picked peak lists of human nonpancreatic synovial phospholipase A 2 , a protein with 124 residues

  3. Patient safety in anesthesia: learning from the culture of high-reliability organizations.

    Science.gov (United States)

    Wright, Suzanne M

    2015-03-01

    There has been an increased awareness of and interest in patient safety and improved outcomes, as well as a growing body of evidence substantiating medical error as a leading cause of death and injury in the United States. According to The Joint Commission, US hospitals demonstrate improvements in health care quality and patient safety. Although this progress is encouraging, much room for improvement remains. High-reliability organizations, industries that deliver reliable performances in the face of complex working environments, can serve as models of safety for our health care system until plausible explanations for patient harm are better understood. Copyright © 2015 Elsevier Inc. All rights reserved.

  4. A generic method for assignment of reliability scores applied to solvent accessibility predictions

    DEFF Research Database (Denmark)

    Petersen, Bent; Petersen, Thomas Nordahl; Andersen, Pernille

    2009-01-01

    : The performance of the neural networks was evaluated on a commonly used set of sequences known as the CB513 set. An overall Pearson's correlation coefficient of 0.72 was obtained, which is comparable to the performance of the currently best public available method, Real-SPINE. Both methods associate a reliability...... comparing the Pearson's correlation coefficient for the upper 20% of predictions sorted according to reliability. For this subset, values of 0.79 and 0.74 are obtained using our and the compared method, respectively. This tendency is true for any selected subset....

  5. A modified strategy for sequence specific assignment of protein NMR spectra based on amino acid type selective experiments

    International Nuclear Information System (INIS)

    Schubert, Mario; Labudde, Dirk; Leitner, Dietmar; Oschkinat, Hartmut; Schmieder, Peter

    2005-01-01

    The determination of the three-dimensional structure of a protein or the study of protein-ligand interactions requires the assignment of all relevant nuclei as an initial step. This is nowadays almost exclusively performed using triple-resonance experiments. The conventional strategy utilizes one or more pairs of three dimensional spectra to obtain redundant information and thus reliable assignments. Here, a modified strategy for obtaining sequence specific assignments based on two dimensional amino acid type selective triple-resonance experiments is proposed. These experiments can be recorded with good resolution in a relatively short time. They provide very specific and redundant information, in particular on sequential connectivities, that drastically increases the ease and reliability of the assignment procedure, done either manually or in an automated fashion. The new strategy is demonstrated with the protein domain PB1 from yeast CDC24p

  6. Reliability of maximal isometric knee strength testing with modified hand-held dynamometry in patients awaiting total knee arthroplasty: useful in research and individual patient settings? A reliability study

    NARCIS (Netherlands)

    Koblbauer, Ian F. H.; Lambrecht, Yannick; van der Hulst, Micheline L. M.; Neeter, Camille; Engelbert, Raoul H. H.; Poolman, Rudolf W.; Scholtes, Vanessa A.

    2011-01-01

    Patients undergoing total knee arthroplasty (TKA) often experience strength deficits both pre- and post-operatively. As these deficits may have a direct impact on functional recovery, strength assessment should be performed in this patient population. For these assessments, reliable measurements

  7. Reliability of maximal isometric knee strength testing with modified hand-held dynamometry in patients awaiting total knee arthroplasty: useful in research and individual patient settings? A reliability study

    NARCIS (Netherlands)

    Koblbauer, I.F.H.; Lambrecht, Y.; van der Hulst, M.L.M.; Neeter, C.; Engelbert, R.H.H.; Poolman, R.W.; Scholtes, V.A.

    2011-01-01

    Background: Patients undergoing total knee arthroplasty (TKA) often experience strength deficits both pre- and post-operatively. As these deficits may have a direct impact on functional recovery, strength assessment should be performed in this patient population. For these assessments, reliable

  8. Feasibility and Inter-Rater Reliability of Physical Performance Measures in Acutely Admitted Older Medical Patients

    DEFF Research Database (Denmark)

    Bodilsen, Ann Christine; Juul-Larsen, Helle Gybel; Petersen, Janne

    2015-01-01

    OBJECTIVE: Physical performance measures can be used to predict functional decline and increased dependency in older persons. However, few studies have assessed the feasibility or reliability of such measures in hospitalized older patients. Here we assessed the feasibility and inter-rater reliabi......OBJECTIVE: Physical performance measures can be used to predict functional decline and increased dependency in older persons. However, few studies have assessed the feasibility or reliability of such measures in hospitalized older patients. Here we assessed the feasibility and inter......-rater reliability of four simple measures of physical performance in acutely admitted older medical patients. DESIGN: During the first 24 hours of hospitalization, the following were assessed twice by different raters in 52 (≥ 65 years) patients admitted for acute medical illness: isometric hand grip strength, 4......, and 30-s chair stand were 8%, 7%, and 18%, and the SRD95% values were 22%, 17%, and 49%. CONCLUSION: In acutely admitted older medical patients, grip strength, gait speed, and the Cumulated Ambulation Score measurements were feasible and showed high inter-rater reliability when administered by different...

  9. Power peaking nuclear reliability factors

    International Nuclear Information System (INIS)

    Hassan, H.A.; Pegram, J.W.; Mays, C.W.; Romano, J.J.; Woods, J.J.; Warren, H.D.

    1977-11-01

    The Calculational Nuclear Reliability Factor (CNRF) assigned to the limiting power density calculated in reactor design has been determined. The CNRF is presented as a function of the relative power density of the fuel assembly and its radial local. In addition, the Measurement Nuclear Reliability Factor (MNRF) for the measured peak hot pellet power in the core has been evaluated. This MNRF is also presented as a function of the relative power density and radial local within the fuel assembly

  10. Reliability of the Superimposed-Burst Technique in Patients With Patellofemoral Pain: A Technical Report.

    Science.gov (United States)

    Norte, Grant E; Frye, Jamie L; Hart, Joseph M

    2015-11-01

    The superimposed-burst (SIB) technique is commonly used to quantify central activation failure after knee-joint injury, but its reliability has not been established in pathologic cohorts. To assess within-session and between-sessions reliability of the SIB technique in patients with patellofemoral pain. Descriptive laboratory study. University laboratory. A total of 10 patients with self-reported patellofemoral pain (1 man, 9 women; age = 24.1 ± 3.8 years, height = 167.8 ± 15.2 cm, mass = 71.6 ± 17.5 kg) and 10 healthy control participants (3 men, 7 women; age = 27.4 ± 5.0 years, height = 173.5 ± 9.9 cm, mass = 78.2 ± 16.5 kg) volunteered. Participants were assessed at 6 intervals spanning 21 days. Intraclass correlation coefficients (ICCs [3,3]) were used to assess reliability. Quadriceps central activation ratio, knee-extension maximal voluntary isometric contraction force, and SIB force. The quadriceps central activation ratio was highly reliable within session (ICC [3,3] = 0.97) and between sessions through day 21 (ICC [3,3] = 0.90-0.95). Acceptable reliability of knee extension (ICC [3,3] = 0.75-0.91) and SIB force (ICC [3,3] = 0.77-0.89) was observed through day 21. The SIB technique was reliable for clinical research up to 21 days in patients with patellofemoral pain.

  11. Failure of a wireless voice communication system to facilitate recording of physician-patient assignment in the emergency department.

    Science.gov (United States)

    Mariani, Peter J

    2008-11-06

    A pilot study was done to assess the feasibility of using a LAN-based voice communication system to convey physician-patient assignment in the emergency department (ED). Via their communicators, physicians were expected to notify registration staff in real-time upon care assumption of each new patient. Over a two month trial, compliance went from poor to dismal, and this method of notification was abandoned.

  12. Comparison of reliability and responsiveness of patient-reported clinical outcome measures in knee osteoarthritis rehabilitation.

    Science.gov (United States)

    Williams, Valerie J; Piva, Sara R; Irrgang, James J; Crossley, Chad; Fitzgerald, G Kelley

    2012-08-01

    Secondary analysis, pretreatment-posttreatment observational study. To compare the reliability and responsiveness of the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), the Knee Outcome Survey activities of daily living subscale (KOS-ADL), and the Lower Extremity Functional Scale (LEFS) in individuals with knee osteoarthritis (OA). The WOMAC is the current standard in patient-reported measures of function in patients with knee OA. The KOS-ADL and LEFS were designed for potential use in patients with knee OA. If the KOS-ADL and LEFS are to be considered viable alternatives to the WOMAC for measuring patient-reported function in individuals with knee OA, they should have measurement properties comparable to the WOMAC. It would also be important to determine whether either of these instruments may be superior to the WOMAC in terms of reliability or responsiveness in this population. Data from 168 subjects with knee OA, who participated in a rehabilitation program, were used in the analyses. Reliability and responsiveness of each outcome measure were estimated at follow-ups of 2, 6, and 12 months. Reliability was estimated by calculating the intraclass correlation coefficient (ICC2,1) for subjects who were unchanged in status from baseline at each follow-up time, based on a global rating of change score. To examine responsiveness, the standard error of the measurement, minimal detectable change, minimal clinically important difference, and the Guyatt responsiveness index were calculated for each outcome measure at each follow-up time. All 3 outcome measures demonstrated reasonable reliability and responsiveness to change. Reliability and responsiveness tended to decrease somewhat with increasing follow-up time. There were no substantial differences between outcome measures for reliability or any of the 3 measures of responsiveness at any follow-up time. The results do not indicate that one outcome measure is more reliable or responsive than

  13. PARAssign-paramagnetic NMR assignments of protein nuclei on the basis of pseudocontact shifts

    Energy Technology Data Exchange (ETDEWEB)

    Skinner, Simon P., E-mail: skinnersp@chem.leidenuniv.nl [Leiden University, Gorlaeus Laboratories, Leiden Institute of Chemistry (Netherlands); Moshev, Mois, E-mail: mois@monomon.me [Leiden University, Leiden Institute of Advanced Computer Science (Netherlands); Hass, Mathias A. S., E-mail: hassmas@chem.leidenuniv.nl; Ubbink, Marcellus, E-mail: m.ubbink@chem.leidenuniv.nl [Leiden University, Gorlaeus Laboratories, Leiden Institute of Chemistry (Netherlands)

    2013-04-15

    The use of paramagnetic NMR data for the refinement of structures of proteins and protein complexes is widespread. However, the power of paramagnetism for protein assignment has not yet been fully exploited. PARAssign is software that uses pseudocontact shift data derived from several paramagnetic centers attached to the protein to obtain amide and methyl assignments. The ability of PARAssign to perform assignment when the positions of the paramagnetic centers are known and unknown is demonstrated. PARAssign has been tested using synthetic data for methyl assignment of a 47 kDa protein, and using both synthetic and experimental data for amide assignment of a 14 kDa protein. The complex fitting space involved in such an assignment procedure necessitates that good starting conditions are found, both regarding placement and strength of paramagnetic centers. These starting conditions are obtained through automated tensor placement and user-defined tensor parameters. The results presented herein demonstrate that PARAssign is able to successfully perform resonance assignment in large systems with a high degree of reliability. This software provides a method for obtaining the assignments of large systems, which may previously have been unassignable, by using 2D NMR spectral data and a known protein structure.

  14. Reliability testing of tendon disease using two different scanning methods in patients with rheumatoid arthritis

    DEFF Research Database (Denmark)

    Bruyn, George A W; Möller, Ingrid; Garrido, Jesus

    2012-01-01

    To assess the intra- and interobserver reliability of musculoskeletal ultrasonography (US) in detecting inflammatory and destructive tendon abnormalities in patients with RA using two different scanning methods.......To assess the intra- and interobserver reliability of musculoskeletal ultrasonography (US) in detecting inflammatory and destructive tendon abnormalities in patients with RA using two different scanning methods....

  15. Reliability of peripheral arterial tonometry in patients with heart failure, diabetic nephropathy and arterial hypertension.

    Science.gov (United States)

    Weisrock, Fabian; Fritschka, Max; Beckmann, Sebastian; Litmeier, Simon; Wagner, Josephine; Tahirovic, Elvis; Radenovic, Sara; Zelenak, Christine; Hashemi, Djawid; Busjahn, Andreas; Krahn, Thomas; Pieske, Burkert; Dinh, Wilfried; Düngen, Hans-Dirk

    2017-08-01

    Endothelial dysfunction plays a major role in cardiovascular diseases and pulse amplitude tonometry (PAT) offers a non-invasive way to assess endothelial dysfunction. However, data about the reliability of PAT in cardiovascular patient populations are scarce. Thus, we evaluated the test-retest reliability of PAT using the natural logarithmic transformed reactive hyperaemia index (LnRHI). Our cohort consisted of 91 patients (mean age: 65±9.7 years, 32% female), who were divided into four groups: those with heart failure with preserved ejection fraction (HFpEF) ( n=25), heart failure with reduced ejection fraction (HFrEF) ( n=22), diabetic nephropathy ( n=21), and arterial hypertension ( n=23). All subjects underwent two separate PAT measurements at a median interval of 7 days (range 4-14 days). LnRHI derived by PAT showed good reliability in subjects with diabetic nephropathy (intra-class correlation (ICC) = 0.863) and satisfactory reliability in patients with both HFpEF (ICC = 0.557) and HFrEF (ICC = 0.576). However, in subjects with arterial hypertension, reliability was poor (ICC = 0.125). We demonstrated that PAT is a reliable technique to assess endothelial dysfunction in adults with diabetic nephropathy, HFpEF or HFrEF. However, in subjects with arterial hypertension, we did not find sufficient reliability, which can possibly be attributed to variations in heart rate and the respective time of the assessments. Clinical Trial Registration Identifier: NCT02299960.

  16. Reliability, Validity, and Responsiveness of InFLUenza Patient-Reported Outcome (FLU-PRO©) Scores in Influenza-Positive Patients.

    Science.gov (United States)

    Powers, John H; Bacci, Elizabeth D; Guerrero, M Lourdes; Leidy, Nancy Kline; Stringer, Sonja; Kim, Katherine; Memoli, Matthew J; Han, Alison; Fairchok, Mary P; Chen, Wei-Ju; Arnold, John C; Danaher, Patrick J; Lalani, Tahaniyat; Ridoré, Michelande; Burgess, Timothy H; Millar, Eugene V; Hernández, Andrés; Rodríguez-Zulueta, Patricia; Smolskis, Mary C; Ortega-Gallegos, Hilda; Pett, Sarah; Fischer, William; Gillor, Daniel; Macias, Laura Moreno; DuVal, Anna; Rothman, Richard; Dugas, Andrea; Ruiz-Palacios, Guillermo M

    2018-02-01

    To assess the reliability, validity, and responsiveness of InFLUenza Patient-Reported Outcome (FLU-PRO©) scores for quantifying the presence and severity of influenza symptoms. An observational prospective cohort study of adults (≥18 years) with influenza-like illness in the United States, the United Kingdom, Mexico, and South America was conducted. Participants completed the 37-item draft FLU-PRO daily for up to 14 days. Item-level and factor analyses were used to remove items and determine factor structure. Reliability of the final tool was estimated using Cronbach α and intraclass correlation coefficients (2-day reliability). Convergent and known-groups validity and responsiveness were assessed using global assessments of influenza severity and return to usual health. Of the 536 patients enrolled, 221 influenza-positive subjects comprised the analytical sample. The mean age of the patients was 40.7 years, 60.2% were women, and 59.7% were white. The final 32-item measure has six factors/domains (nose, throat, eyes, chest/respiratory, gastrointestinal, and body/systemic), with a higher order factor representing symptom severity overall (comparative fit index = 0.92; root mean square error of approximation = 0.06). Cronbach α was high (total = 0.92; domain range = 0.71-0.87); test-retest reliability (intraclass correlation coefficient, day 1-day 2) was 0.83 for total scores and 0.57 to 0.79 for domains. Day 1 FLU-PRO domain and total scores were moderately to highly correlated (≥0.30) with Patient Global Rating of Flu Severity (except nose and throat). Consistent with known-groups validity, scores differentiated severity groups on the basis of global rating (total: F = 57.2, P FLU-PRO score improvement by day 7 than did those who did not, suggesting score responsiveness. Results suggest that FLU-PRO scores are reliable, valid, and responsive to change in influenza-positive adults. Copyright © 2018 International Society for Pharmacoeconomics and Outcomes

  17. VALIDITY AND RELIABILITY OF THE SPIRITUAL COPING STRATEGIES SCALE ARABIC VERSION IN SAUDI PATIENTS UNDERGOING HAEMODIALYSIS.

    Science.gov (United States)

    Cruz, Jonas P; Baldacchino, Donia R; Alquwez, Nahed

    2016-06-01

    Patients often resort to religious and spiritual activities to cope with physical and mental challenges. The effect of spiritual coping on overall health, adaptation and health-related quality of life among patients undergoing haemodialysis (HD) is well documented. Thus, it is essential to establish a valid and reliable instrument that can assess both the religious and non-religious coping methods in patients undergoing HD. This study aimed to assess the validity and reliability of the Spiritual Coping Strategies Scale Arabic version (SCS-A) in Saudi patients undergoing HD. A convenience sample of 60 Saudi patients undergoing HD was recruited for this descriptive, cross-sectional study. Data were collected between May and June 2015. Forward-backward translation was used to formulate the SCS-A. The SCS-A, Muslim Religiosity Scale and the Quality of Life Index Dialysis Version III were used to procure the data. Internal consistency reliability, stability reliability, factor analysis and construct validity tests were performed. Analyses were set at the 0.05 level of significance. The SCS-A showed an acceptable internal consistency and strong stability reliability over time. The EFA produced two factors (non-religious and religious coping). Satisfactory construct validity was established by the convergent and divergent validity and known-groups method. The SCS-A is a reliable and valid tool that can be used to measure the religious and non-religious coping strategies of patients undergoing HD in Saudi Arabia and other Muslim and Arabic-speaking countries. © 2016 European Dialysis and Transplant Nurses Association/European Renal Care Association.

  18. Interrater and Intrarater Reliability of the Balance Computerized Adaptive Test in Patients With Stroke.

    Science.gov (United States)

    Chiang, Hsin-Yu; Lu, Wen-Shian; Yu, Wan-Hui; Hsueh, I-Ping; Hsieh, Ching-Lin

    2018-04-11

    To examine the interrater and intrarater reliability of the Balance Computerized Adaptive Test (Balance CAT) in patients with chronic stroke having a wide range of balance functions. Repeated assessments design (1wk apart). Seven teaching hospitals. A pooled sample (N=102) including 2 independent groups of outpatients (n=50 for the interrater reliability study; n=52 for the intrarater reliability study) with chronic stroke. Not applicable. Balance CAT. For the interrater reliability study, the values of intraclass correlation coefficient, minimal detectable change (MDC), and percentage of MDC (MDC%) for the Balance CAT were .84, 1.90, and 31.0%, respectively. For the intrarater reliability study, the values of intraclass correlation coefficient, MDC, and MDC% ranged from .89 to .91, from 1.14 to 1.26, and from 17.1% to 18.6%, respectively. The Balance CAT showed sufficient intrarater reliability in patients with chronic stroke having balance functions ranging from sitting with support to independent walking. Although the Balance CAT may have good interrater reliability, we found substantial random measurement error between different raters. Accordingly, if the Balance CAT is used as an outcome measure in clinical or research settings, same raters are suggested over different time points to ensure reliable assessments. Copyright © 2018 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  19. Reliability and validity of the Beck depression inventory in patients with Parkinson's disease

    NARCIS (Netherlands)

    Visser, Martine; Leentjens, Albert F. G.; Marinus, Johan; Stiggelbout, Anne M.; van Hilten, Jacobus J.

    2006-01-01

    We evaluated the validity, reliability, and potential responsiveness of the Beck Depression Inventory (BDI) in patients with Parkinson's disease (PD). In part 1 of the study, 92 patients with PD underwent a structured clinical interview for DSM major depression and based on this patients were

  20. Improvement of standards on functional reliability of electric power systems

    International Nuclear Information System (INIS)

    Barinov, V.A.; Volkov, G.A.; Kalita, V.V.; Kogan, F.L.; Makarov, S.F.; Manevich, A.S.; Mogirev, V.V.; Sin'chugov, F.I.; Skopintsev, V.A.; Khvoshchinskaya, Z.G.

    1993-01-01

    Analysis of the most principal aspects of the existing standards and requirements on assuring safety and stability of electric power systems (EPS) and effective (reliable and economical) power supply of consumers is given. The reliability is determined as ability to accomplish the assigned functions. Basic recommendations on improving the standards regulating the safety and reliability of the NPP functioning are formulated

  1. Intra-observer and interobserver reliability ofOne Leg Stand Test as a measure of posturalbalance in low back pain patients

    DEFF Research Database (Denmark)

    Maribo, Thomas; Iversen, Elena; Andersen, Niels Trolle

    2009-01-01

    Objective: To determine the absolute and relative reliability of intra-observer and interobserver To determine the absolute and relative reliability of intra-observer and interobserver measurements of postural balance using the One Leg Stand Test in patients with low back pain. Patients and methods...... to stand for the maximum time, and no further analysis was done. Eyes closed: intra-observer reliability was tested in 21 patients; absolute reliability showed a standard error of the measurement (SEM) of 2.48 s and a minimal detectable change (MDC) of 6.88. The relative reliability was acceptable...... with an intra class correlation coefficient (ICC) of 0.86. Interobserver reliability was tested in 27 patients; absolute reliability showed a SEM of 1.42 s and a MDC of 3.95. The relative reliability was acceptable with an ICC of 0.91. Conclusions: The One Leg Stand Test can be used to test postural balance...

  2. Reliability and Validity of Modified Service Quality Instrument (SERVQUAL) in Patients' Motivation to Adhere to Insulin Therapy.

    Science.gov (United States)

    Jakupovic, Vedran; Solakovic, Suajb; Celebic, Nedim; Kulovic, Dzenan

    2018-03-01

    Diabetes is progressive condition which requires various ways of treatment. Adequate therapy prescribed in the right time helps patient to postpone development of complications. Adherence to complicated therapy is challenge for both patients and HCPs and is subject of research in many disciplines. Improvement in communication between HCP and patients is very important in patient's adherence to therapy. Aim of this research was to explore validity and reliability of modified SERVQUAL instrument in attempt to explore ways of motivating diabetic patient to accept prescribed insulin therapy. We used modified SERVQUAL questionnaire as instrument in the research. It was necessary to check validity and reliability of the new modified instrument. Results show that modified Servqual instrument has excellent reliability (α=0.908), so we could say that it measures precisely Expectations, Perceptions and Motivation at patients. Factor analysis (EFA method) with Varimax rotation extracted 4 factors which together explain 52.902% variance of the results on this subscale. Bifactorial solution could be seen on Scree-plot diagram (break at second factor). Results in this research show that modified Servqual instrument which is created in order to measure expectations and perceptions of the patients is valid and reliable. Reliability and validity are proven indeed in additional dimension which was created originally for this research - motivation to accept insulin therapy.

  3. Reliability and validity of the visual analogue scale for disability in patients with chronic musculoskeletal pain.

    Science.gov (United States)

    Boonstra, Anne M; Schiphorst Preuper, Henrica R; Reneman, Michiel F; Posthumus, Jitze B; Stewart, Roy E

    2008-06-01

    To determine the reliability and concurrent validity of a visual analogue scale (VAS) for disability as a single-item instrument measuring disability in chronic pain patients was the objective of the study. For the reliability study a test-retest design and for the validity study a cross-sectional design was used. A general rehabilitation centre and a university rehabilitation centre was the setting for the study. The study population consisted of patients over 18 years of age, suffering from chronic musculoskeletal pain; 52 patients in the reliability study, 344 patients in the validity study. Main outcome measures were as follows. Reliability study: Spearman's correlation coefficients (rho values) of the test and retest data of the VAS for disability; validity study: rho values of the VAS disability scores with the scores on four domains of the Short-Form Health Survey (SF-36) and VAS pain scores, and with Roland-Morris Disability Questionnaire scores in chronic low back pain patients. Results were as follows: in the reliability study rho values varied from 0.60 to 0.77; and in the validity study rho values of VAS disability scores with SF-36 domain scores varied from 0.16 to 0.51, with Roland-Morris Disability Questionnaire scores from 0.38 to 0.43 and with VAS pain scores from 0.76 to 0.84. The conclusion of the study was that the reliability of the VAS for disability is moderate to good. Because of a weak correlation with other disability instruments and a strong correlation with the VAS for pain, however, its validity is questionable.

  4. Day hospital as an alternative to inpatient care for cancer patients: a random assignment trial.

    Science.gov (United States)

    Mor, V; Stalker, M Z; Gralla, R; Scher, H I; Cimma, C; Park, D; Flaherty, A M; Kiss, M; Nelson, P; Laliberte, L

    1988-01-01

    A stratified, random-assignment trial of 442 cancer patients was conducted to evaluate medical, psychosocial, and financial outcomes of day hospital treatment as an alternative to inpatient care for certain cancer patients. Eligible patients required: a 4- to 8-hour treatment plan, including chemotherapy and other long-term intravenous (i.v.) treatment; a stable cardiovascular status; mental competence; no skilled overnight nursing; and a helper to assist with home care. Patients were ineligible if standard outpatient treatment was possible. No statistically significant (p less than 0.05) differences were found between the Adult Day Hospital (ADH) and Inpatient care in medical or psychosocial outcomes over the 60-day study period. The major difference was in medical costs--approximately one-third lower for ADH patients (p less than 0.001) than for the Inpatient group. The study demonstrates that day hospital care of medical oncology patients is clinically equivalent to Inpatient care, causes no negative psychosocial effects, and costs less than Inpatient care. Findings support the trend toward dehospitalization of medical treatment.

  5. Maximal network reliability for a stochastic power transmission network

    International Nuclear Information System (INIS)

    Lin, Yi-Kuei; Yeh, Cheng-Ta

    2011-01-01

    Many studies regarded a power transmission network as a binary-state network and constructed it with several arcs and vertices to evaluate network reliability. In practice, the power transmission network should be stochastic because each arc (transmission line) combined with several physical lines is multistate. Network reliability is the probability that the network can transmit d units of electric power from a power plant (source) to a high voltage substation at a specific area (sink). This study focuses on searching for the optimal transmission line assignment to the power transmission network such that network reliability is maximized. A genetic algorithm based method integrating the minimal paths and the Recursive Sum of Disjoint Products is developed to solve this assignment problem. A real power transmission network is adopted to demonstrate the computational efficiency of the proposed method while comparing with the random solution generation approach.

  6. Likelihood of being seen within emergency departments’ assigned urgency times for poisoned and injured individuals

    Directory of Open Access Journals (Sweden)

    Rachel L. Rosenthal

    2014-10-01

    Full Text Available The objective of the present study is to determine the likelihood of injured or poisoned patients in special populations, such as those patients that are elderly and self-injurious, being seen within an emergency department’s triage nurse assigned urgency. Data from the National Hospital Ambulatory Medical Care Survey (2007 was utilized in this study. Multi-level models and multivariate linear regression models were used; patient age, sex, reported pain levels, wait time, and injury type were examined as potential predictors of being seen within assigned urgency. From a random sample across all US Emergency Departments, 5616 patients nested in 312 hospital emergency departments were included into the study. Typically, approximately 1 in 5 emergency department patients were not seen within their triage nurse assigned urgencies. The typical patient in the average hospital had an 81% likelihood of being seen within their assigned urgency. P atients who were oldest [odds ratio (OR=0.0990] and had self-inflicted injuries (vs assault OR=1.246 and OR=1.596 had the least likelihood to be seen within their assigned urgencies. As actual wait-time increased for patients, they were less likely to be seen within their assigned urgencies. The most powerful predictors of the study’s outcome were injury type and age, indicating that patients from special populations such as the elderly or those with injuries resulting from deliberate self-harm are less likely to be actually priority patients independent of triage nurse assigned urgencies.

  7. Teachers grading practices : an analysis of the reliability of teacher-assigned grade point average (GPA)

    NARCIS (Netherlands)

    van der Lans, R. M.; van de Grift, W. J. C. M.; van Veen, K.

    2015-01-01

    In previous research, teachers report that they use a hodgepodge of factors when grading students. This has led researchers to suspect that teacher-assigned grades are inflated by teacher-student interactions; the hodgepodge hypothesis. Teachers also are reported to differ in grading leniency; the

  8. High inter-tester reliability of the new mobility score in patients with hip fracture

    DEFF Research Database (Denmark)

    Kristensen, M.T.; Bandholm, T.; Foss, N.B.

    2008-01-01

    OBJECTIVE: To assess the inter-tester reliability of the New Mobility Score in patients with acute hip fracture. DESIGN: An inter-tester reliability study. SUBJECTS: Forty-eight consecutive patients with acute hip fracture at a median age of 84 (interquartile range, 76-89) years; 40 admitted from...... their own home and 8 from nursing homes to an acute orthopaedic hip fracture unit at a university hospital. METHODS: The New Mobility Score, which evaluates the prefracture functional level with a score from 0 (not able to walk at all) to 9 (fully independent), was assessed by 2 independent physiotherapists...... the prefracture functional level in patients with acute hip fracture Udgivelsesdato: 2008/7...

  9. Wildlife forensic science: A review of genetic geographic origin assignment.

    Science.gov (United States)

    Ogden, Rob; Linacre, Adrian

    2015-09-01

    Wildlife forensic science has become a key means of enforcing legislation surrounding the illegal trade in protected and endangered species. A relatively new dimension to this area of forensic science is to determine the geographic origin of a seized sample. This review focuses on DNA testing, which relies on assignment of an unknown sample to its genetic population of origin. Key examples of this are the trade in timber, fish and ivory and these are used only to illustrate the large number of species for which this type of testing is potentially available. The role of mitochondrial and nuclear DNA markers is discussed, alongside a comparison of neutral markers with those exhibiting signatures of selection, which potentially offer much higher levels of assignment power to address specific questions. A review of assignment tests is presented along with detailed methods for evaluating error rates and considerations for marker selection. The availability and quality of reference data are of paramount importance to support assignment applications and ensure reliability of any conclusions drawn. The genetic methods discussed have been developed initially as investigative tools but comment is made regarding their use in courts. The potential to compliment DNA markers with elemental assays for greater assignment power is considered and finally recommendations are made for the future of this type of testing. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  10. Validity and Reliability of Accelerometers in Patients With COPD: A SYSTEMATIC REVIEW.

    Science.gov (United States)

    Gore, Shweta; Blackwood, Jennifer; Guyette, Mary; Alsalaheen, Bara

    2018-05-01

    Reduced physical activity is associated with poor prognosis in chronic obstructive pulmonary disease (COPD). Accelerometers have greatly improved quantification of physical activity by providing information on step counts, body positions, energy expenditure, and magnitude of force. The purpose of this systematic review was to compare the validity and reliability of accelerometers used in patients with COPD. An electronic database search of MEDLINE and CINAHL was performed. Study quality was assessed with the Strengthening the Reporting of Observational Studies in Epidemiology checklist while methodological quality was assessed using the modified Quality Appraisal Tool for Reliability Studies. The search yielded 5392 studies; 25 met inclusion criteria. The SenseWear Pro armband reported high criterion validity under controlled conditions (r = 0.75-0.93) and high reliability (ICC = 0.84-0.86) for step counts. The DynaPort MiniMod demonstrated highest concurrent validity for step count using both video and manual methods. Validity of the SenseWear Pro armband varied between studies especially in free-living conditions, slower walking speeds, and with addition of weights during gait. A high degree of variability was found in the outcomes used and statistical analyses performed between studies, indicating a need for further studies to measure reliability and validity of accelerometers in COPD. The SenseWear Pro armband is the most commonly used accelerometer in COPD, but measurement properties are limited by gait speed variability and assistive device use. DynaPort MiniMod and Stepwatch accelerometers demonstrated high validity in patients with COPD but lack reliability data.

  11. The impact of revised DSM-5 criteria on the relative distribution and inter-rater reliability of eating disorder diagnoses in a residential treatment setting.

    Science.gov (United States)

    Thomas, Jennifer J; Eddy, Kamryn T; Murray, Helen B; Tromp, Marilou D P; Hartmann, Andrea S; Stone, Melissa T; Levendusky, Philip G; Becker, Anne E

    2015-09-30

    This study evaluated the relative distribution and inter-rater reliability of revised DSM-5 criteria for eating disorders in a residential treatment program. Consecutive adolescent and young adult females (N=150) admitted to a residential eating disorder treatment facility were assigned both DSM-IV and DSM-5 diagnoses by a clinician (n=14) via routine clinical interview and a research assessor (n=4) via structured interview. We compared the frequency of diagnostic assignments under each taxonomy and by type of assessor. We evaluated concordance between clinician and researcher assignment through inter-rater reliability kappa and percent agreement. Significantly fewer patients received either clinician or researcher diagnoses of a residual eating disorder under DSM-5 (clinician-12.0%; researcher-31.3%) versus DSM-IV (clinician-28.7%; researcher-59.3%), with the majority of reassigned DSM-IV residual cases reclassified as DSM-5 anorexia nervosa. Researcher and clinician diagnoses showed moderate inter-rater reliability under DSM-IV (κ=.48) and DSM-5 (κ=.57), though agreement for specific DSM-5 other specified feeding or eating disorder (OSFED) presentations was poor (κ=.05). DSM-5 revisions were associated with significantly less frequent residual eating disorder diagnoses, but not with reduced inter-rater reliability. Findings support specific dimensions of clinical utility for revised DSM-5 criteria for eating disorders. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  12. Interrater reliability of the Volume-Viscosity Swallow Test; screening for dysphagia among hospitalized elderly medical patients.

    Science.gov (United States)

    Jørgensen, Lise Walther; Søndergaard, Kasper; Melgaard, Dorte; Warming, Susan

    2017-12-01

    Oropharyngeal dysphagia (OD) is prevalent among medical and geriatric patients admitted due to acute illness and it is associated with malnutrition, increased length of stay and increased mortality. A valid and reliable bedside screening test for patients at risk of OD is essential in order to detect patients in need of further assessment. The Volume-Viscosity Swallow Test (V-VST) has been shown to be a valid screening test for OD in mixed outpatient populations. However, as reliability of the test has yet to be investigated in a population of medical and geriatric patients admitted due to acute illness, we aimed to determine the interrater reliability of the V-VST in this clinical setting. Reporting in this study is in accordance with proposed guidelines for the reporting of reliability and agreement studies (GRRAS). In three Danish hospitals (CRD-BFH, CRD-GH, NDR-H) 11 skilled occupational therapists examined an unselected group of 110 patients admitted to geriatric or medical wards. In an overall agreement phase raters reached ≥80% agreement before data collection phase was commenced. The V-VST was applied to patients twice within maximum one hour by raters who administrated the test in an order based on randomization, blinded to each other's results. Agreement, Kappa values, weighed Kappa values and Kappa adjusted for bias and prevalence are reported. The interrater reliability of V-VST as screening test for OD in patients admitted to geriatric or medical wards was substantial with an overall Kappa value of 0.77 (95% CI 0.65-0.89) however interrater reliability varied among hospitals ranging from 0.37 (95% CI -0.01 to 0.41) to 0.85 (95% CI 0.75-1.00). Interrater reliability of the accompanying recommendations of volume and viscosity was moderate with a weighted kappa value of 0.55 (95% CI 0.37-0.73) for viscosity and 0.53 (95% CI 0.36-0.7) for volume. The overall prevalence of OD was 34.5%, ranging from 8% to 53.6% across hospitals. The prevalence and bias

  13. Reliability of intra-oral quantitative sensory testing (QST) in patients with atypical odontalgia and healthy controls - a multicentre study.

    Science.gov (United States)

    Baad-Hansen, L; Pigg, M; Yang, G; List, T; Svensson, P; Drangsholt, M

    2015-02-01

    The reliability of comprehensive intra-oral quantitative sensory testing (QST) protocol has not been examined systematically in patients with chronic oro-facial pain. The aim of the present multicentre study was to examine test-retest and interexaminer reliability of intra-oral QST measures in terms of absolute values and z-scores as well as within-session coefficients of variation (CV) values in patients with atypical odontalgia (AO) and healthy pain-free controls. Forty-five patients with AO and 68 healthy controls were subjected to bilateral intra-oral gingival QST and unilateral extratrigeminal QST (thenar) on three occasions (twice on 1 day by two different examiners and once approximately 1 week later by one of the examiners). Intra-class correlation coefficients and kappa values for interexaminer and test-retest reliability were computed. Most of the standardised intra-oral QST measures showed fair to excellent interexaminer (9-12 of 13 measures) and test-retest (7-11 of 13 measures) reliability. Furthermore, no robust differences in reliability measures or within-session variability (CV) were detected between patients with AO and the healthy reference group. These reliability results in chronic orofacial pain patients support earlier suggestions based on data from healthy subjects that intra-oral QST is sufficiently reliable for use as a part of a comprehensive evaluation of patients with somatosensory disturbances or neuropathic pain in the trigeminal region. © 2014 John Wiley & Sons Ltd.

  14. New assignment of 14N NQR spectral lines for tetrazoles derivatives

    Science.gov (United States)

    Mamadazizov, Sultonazar; Shelyapina, Marina G.; Kupriyanova, Galina S.; Mozzhukhin, George V.

    2018-04-01

    In recent years, considerable interest has been shown in the study of tetrazole derivatives, which attract attention as highly nitrogenous compounds for use as an isosteric substitutes for various functional groups that leads to creation of novel biologically active substances. NQR techniques, being sensitive to the local environment of 14N nuclei, provide great opportunities to study these new substances. To make investigation of complex compounds containing tetrazoles derivatives easier and more reliable a correctly assigned 14N NQR spectra of tetrazoles are required. Here we report on the results of our DFT B3LYP calculations of 14N NQR spectral parameters (quadrupole coupling constant Qcc and the asymmetry parameter of the electric field gradient η) for tetrazole, 5-aminotetrazole and 5-aminotetrazole monohydrate. It has been found that the commonly accepted assignment of the 14N NQR spectral lines for these molecules is incorrect. A new assignment for these molecules is proposed.

  15. Reliability of the Life Satisfaction Questionnaire to assess patients with chronic musculoskeletal pain

    NARCIS (Netherlands)

    Boonstra, Anne M.; Reneman, Michiel F.; Posthumus, Jitze B.; Stewart, Roy E.; Schiphorst Preuper, Henrica R.

    The aim of this study was to determine the reliability of the Life Satisfaction Questionnaire, Dutch version (LSQ-DV), to assess chronic pain patients. The study was designed as test-retest. The setting was the general rehabilitation centre. There were 51 patients over 18 years of age, suffering

  16. An OMERACT reliability exercise of inflammatory and structural abnormalities in patients with knee osteoarthritis using ultrasound assessment

    DEFF Research Database (Denmark)

    Bruyn, George Aw; Naredo, Esperanza; Damjanov, Nemanja

    2016-01-01

    OBJECTIVE: To assess whether ultrasonography (US) is reliable for the evaluation of inflammatory and structural abnormalities in patients with knee osteoarthritis (OA). METHODS: Thirteen patients with early knee OA were examined by 11 experienced sonographers during 2 days. Dichotomous and semiqu......OBJECTIVE: To assess whether ultrasonography (US) is reliable for the evaluation of inflammatory and structural abnormalities in patients with knee osteoarthritis (OA). METHODS: Thirteen patients with early knee OA were examined by 11 experienced sonographers during 2 days. Dichotomous...

  17. Performance evaluation of distributed wavelength assignment in WDM optical networks

    Science.gov (United States)

    Hashiguchi, Tomohiro; Wang, Xi; Morikawa, Hiroyuki; Aoyama, Tomonori

    2004-04-01

    In WDM wavelength routed networks, prior to a data transfer, a call setup procedure is required to reserve a wavelength path between the source-destination node pairs. A distributed approach to a connection setup can achieve a very high speed, while improving the reliability and reducing the implementation cost of the networks. However, along with many advantages, several major challenges have been posed by the distributed scheme in how the management and allocation of wavelength could be efficiently carried out. In this thesis, we apply a distributed wavelength assignment algorithm named priority based wavelength assignment (PWA) that was originally proposed for the use in burst switched optical networks to the problem of reserving wavelengths of path reservation protocols in the distributed control optical networks. Instead of assigning wavelengths randomly, this approach lets each node select the "safest" wavelengths based on the information of wavelength utilization history, thus unnecessary future contention is prevented. The simulation results presented in this paper show that the proposed protocol can enhance the performance of the system without introducing any apparent drawbacks.

  18. A fuzzy logic algorithm to assign confidence levels to heart and respiratory rate time series

    International Nuclear Information System (INIS)

    Liu, J; McKenna, T M; Gribok, A; Reifman, J; Beidleman, B A; Tharion, W J

    2008-01-01

    We have developed a fuzzy logic-based algorithm to qualify the reliability of heart rate (HR) and respiratory rate (RR) vital-sign time-series data by assigning a confidence level to the data points while they are measured as a continuous data stream. The algorithm's membership functions are derived from physiology-based performance limits and mass-assignment-based data-driven characteristics of the signals. The assigned confidence levels are based on the reliability of each HR and RR measurement as well as the relationship between them. The algorithm was tested on HR and RR data collected from subjects undertaking a range of physical activities, and it showed acceptable performance in detecting four types of faults that result in low-confidence data points (receiver operating characteristic areas under the curve ranged from 0.67 (SD 0.04) to 0.83 (SD 0.03), mean and standard deviation (SD) over all faults). The algorithm is sensitive to noise in the raw HR and RR data and will flag many data points as low confidence if the data are noisy; prior processing of the data to reduce noise allows identification of only the most substantial faults. Depending on how HR and RR data are processed, the algorithm can be applied as a tool to evaluate sensor performance or to qualify HR and RR time-series data in terms of their reliability before use in automated decision-assist systems

  19. On the design of high-rise buildings with a specified level of reliability

    Science.gov (United States)

    Dolganov, Andrey; Kagan, Pavel

    2018-03-01

    High-rise buildings have a specificity, which significantly distinguishes them from traditional buildings of high-rise and multi-storey buildings. Steel structures in high-rise buildings are advisable to be used in earthquake-proof regions, since steel, due to its plasticity, provides damping of the kinetic energy of seismic impacts. These aspects should be taken into account when choosing a structural scheme of a high-rise building and designing load-bearing structures. Currently, modern regulatory documents do not quantify the reliability of structures. Although the problem of assigning an optimal level of reliability has existed for a long time. The article shows the possibility of designing metal structures of high-rise buildings with specified reliability. Currently, modern regulatory documents do not quantify the reliability of high-rise buildings. Although the problem of assigning an optimal level of reliability has existed for a long time. It is proposed to establish the value of reliability 0.99865 (3σ) for constructions of buildings and structures of a normal level of responsibility in calculations for the first group of limiting states. For increased (construction of high-rise buildings) and reduced levels of responsibility for the provision of load-bearing capacity, it is proposed to assign respectively 0.99997 (4σ) and 0.97725 (2σ). The coefficients of the use of the cross section of a metal beam for different levels of security are given.

  20. Construct Validity and Reliability of the Questionnaire on the Quality of Physician-Patient Interaction in Adults With Hypertension.

    Science.gov (United States)

    Hickman, Ronald L; Clochesy, John M; Hetland, Breanna; Alaamri, Marym

    2017-04-01

    There are limited reliable and valid measures of the patient- provider interaction among adults with hypertension. Therefore, the purpose of this report is to describe the construct validity and reliability of the Questionnaire on the Quality of Physician-Patient Interaction (QQPPI), in community-dwelling adults with hypertension. A convenience sample of 109 participants with hypertension was recruited and administered the QQPPI at baseline and 8 weeks later. The exploratory factor analysis established a 12-item, 2-factor structure for the QQPPI was valid in this sample. The modified QQPPI proved to have sufficient internal consistency and test- retest reliability. The modified QQPPI is a valid and reliable measure of the provider-patient interaction, a construct posited to impact self-management, in adults with hypertension.

  1. Life Satisfaction Questionnaire (Lisat-9): Reliability and Validity for Patients with Acquired Brain Injury

    Science.gov (United States)

    Boonstra, Anne M.; Reneman, Michiel F.; Stewart, Roy E.; Balk, Gerlof A.

    2012-01-01

    The aim of this study was to determine the reliability and discriminant validity of the Dutch version of the life satisfaction questionnaire (Lisat-9 DV) to assess patients with an acquired brain injury. The reliability study used a test-retest design, and the validity study used a cross-sectional design. The setting was the general rehabilitation…

  2. Intra- and inter-rater reliability of the Sollerman hand function test in patients with chronic stroke

    DEFF Research Database (Denmark)

    Brogårdh, Christina; Persson, Ann L; Sjölund, Bengt H

    2007-01-01

    PURPOSE: To examine whether the Sollerman hand function test is reliable in a test-retest situation in patients with chronic stroke. METHOD: Three independent examiners observed each patient at three experimental sessions; two days in week 1 (short-term test-retest) and one day in week 4 (long...... test seems to be a reliable test in patients with chronic stroke, but we recommend that the same examiner evaluates a patient's hand function pre- and post-treatment.......-term test-retest). A total of 24 patients with chronic stroke (mean age; 59.7 years, mean time since stroke onset 29.6 months) participated. The examiners simultaneously assessed the patients' ability to perform 20 subtests. Both ordinal data (generalized kappa) and total sum scores (Spearman's rank...

  3. Reliability of TMS metrics in patients with chronic incomplete spinal cord injury.

    Science.gov (United States)

    Potter-Baker, K A; Janini, D P; Frost, F S; Chabra, P; Varnerin, N; Cunningham, D A; Sankarasubramanian, V; Plow, E B

    2016-11-01

    Test-retest reliability analysis in individuals with chronic incomplete spinal cord injury (iSCI). The purpose of this study was to examine the reliability of neurophysiological metrics acquired with transcranial magnetic stimulation (TMS) in individuals with chronic incomplete tetraplegia. Cleveland Clinic Foundation, Cleveland, Ohio, USA. TMS metrics of corticospinal excitability, output, inhibition and motor map distribution were collected in muscles with a higher MRC grade and muscles with a lower MRC grade on the more affected side of the body. Metrics denoting upper limb function were also collected. All metrics were collected at two sessions separated by a minimum of two weeks. Reliability between sessions was determined using Spearman's correlation coefficients and concordance correlation coefficients (CCCs). We found that TMS metrics that were acquired in higher MRC grade muscles were approximately two times more reliable than those collected in lower MRC grade muscles. TMS metrics of motor map output, however, demonstrated poor reliability regardless of muscle choice (P=0.34; CCC=0.51). Correlation analysis indicated that patients with more baseline impairment and/or those in a more chronic phase of iSCI demonstrated greater variability of metrics. In iSCI, reliability of TMS metrics varies depending on the muscle grade of the tested muscle. Variability is also influenced by factors such as baseline motor function and time post SCI. Future studies that use TMS metrics in longitudinal study designs to understand functional recovery should be cautious as choice of muscle and clinical characteristics can influence reliability.

  4. Protein secondary structure assignment revisited: a detailed analysis of different assignment methods

    Directory of Open Access Journals (Sweden)

    de Brevern Alexandre G

    2005-09-01

    Full Text Available Abstract Background A number of methods are now available to perform automatic assignment of periodic secondary structures from atomic coordinates, based on different characteristics of the secondary structures. In general these methods exhibit a broad consensus as to the location of most helix and strand core segments in protein structures. However the termini of the segments are often ill-defined and it is difficult to decide unambiguously which residues at the edge of the segments have to be included. In addition, there is a "twilight zone" where secondary structure segments depart significantly from the idealized models of Pauling and Corey. For these segments, one has to decide whether the observed structural variations are merely distorsions or whether they constitute a break in the secondary structure. Methods To address these problems, we have developed a method for secondary structure assignment, called KAKSI. Assignments made by KAKSI are compared with assignments given by DSSP, STRIDE, XTLSSTR, PSEA and SECSTR, as well as secondary structures found in PDB files, on 4 datasets (X-ray structures with different resolution range, NMR structures. Results A detailed comparison of KAKSI assignments with those of STRIDE and PSEA reveals that KAKSI assigns slightly longer helices and strands than STRIDE in case of one-to-one correspondence between the segments. However, KAKSI tends also to favor the assignment of several short helices when STRIDE and PSEA assign longer, kinked, helices. Helices assigned by KAKSI have geometrical characteristics close to those described in the PDB. They are more linear than helices assigned by other methods. The same tendency to split long segments is observed for strands, although less systematically. We present a number of cases of secondary structure assignments that illustrate this behavior. Conclusion Our method provides valuable assignments which favor the regularity of secondary structure segments.

  5. Analysis of NPP protection structure reliability under impact of a falling aircraft

    International Nuclear Information System (INIS)

    Shul'man, G.S.

    1996-01-01

    Methodology for evaluation of NPP protection structure reliability by impact of aircraft fall down is considered. The methodology is base on the probabilistic analysis of all potential events. The problem is solved in three stages: determination of loads on structural units, calculation of local reliability of protection structures by assigned loads and estimation of the structure reliability. The methodology proposed may be applied at the NPP design stage and by determination of reliability of already available structures

  6. Reliability and responsiveness of algometry for measuring pressure pain threshold in patients with knee osteoarthritis.

    Science.gov (United States)

    Mutlu, Ebru Kaya; Ozdincler, Arzu Razak

    2015-06-01

    [Purpose] This study aimed to establish the intrarater reliability and responsiveness of a clinically available algometer in patients with knee osteoarthritis as well as to determine the minimum-detectable-change and standard error of measurement of testing to facilitate clinical interpretation of temporal changes. [Subjects] Seventy-three patients with knee osteoarthritis were included. [Methods] Pressure pain threshold measured by algometry was evaluated 3 times at 2-min intervals over 2 clinically relevant sites-mediolateral to the medial femoral tubercle (distal) and lateral to the medial malleolus (local)-on the same day. Intrarater reliability was estimated by intraclass correlation coefficients. The minimum-detectable-change and standard error of measurement were calculated. As a measure of responsiveness, the effect size was calculated for the results at baseline and after treatment. [Results] The intrarater reliability was almost perfect (intraclass correlation coefficient = 0.93-0.97). The standard error of measurement and minimum-detectable-change were 0.70-0.66 and 1.62-1.53, respectively. The pressure pain threshold over the distal site was inadequately responsive in knee osteoarthritis, but the local site was responsive. The effect size was 0.70. [Conclusion] Algometry is reliable and responsive to assess measures of pressure pain threshold for evaluating pain patients with knee osteoarthritis.

  7. Evaluating test-retest reliability in patient-reported outcome measures for older people: A systematic review.

    Science.gov (United States)

    Park, Myung Sook; Kang, Kyung Ja; Jang, Sun Joo; Lee, Joo Yun; Chang, Sun Ju

    2018-03-01

    This study aimed to evaluate the components of test-retest reliability including time interval, sample size, and statistical methods used in patient-reported outcome measures in older people and to provide suggestions on the methodology for calculating test-retest reliability for patient-reported outcomes in older people. This was a systematic literature review. MEDLINE, Embase, CINAHL, and PsycINFO were searched from January 1, 2000 to August 10, 2017 by an information specialist. This systematic review was guided by both the Preferred Reporting Items for Systematic Reviews and Meta-Analyses checklist and the guideline for systematic review published by the National Evidence-based Healthcare Collaborating Agency in Korea. The methodological quality was assessed by the Consensus-based Standards for the selection of health Measurement Instruments checklist box B. Ninety-five out of 12,641 studies were selected for the analysis. The median time interval for test-retest reliability was 14days, and the ratio of sample size for test-retest reliability to the number of items in each measure ranged from 1:1 to 1:4. The most frequently used statistical methods for continuous scores was intraclass correlation coefficients (ICCs). Among the 63 studies that used ICCs, 21 studies presented models for ICC calculations and 30 studies reported 95% confidence intervals of the ICCs. Additional analyses using 17 studies that reported a strong ICC (>0.09) showed that the mean time interval was 12.88days and the mean ratio of the number of items to sample size was 1:5.37. When researchers plan to assess the test-retest reliability of patient-reported outcome measures for older people, they need to consider an adequate time interval of approximately 13days and the sample size of about 5 times the number of items. Particularly, statistical methods should not only be selected based on the types of scores of the patient-reported outcome measures, but should also be described clearly in

  8. Reliability and Validity Study of a Tool to Measure Cancer Stigma: Patient Version.

    Science.gov (United States)

    Yılmaz, Medine; Dişsiz, Gülçin; Demir, Filiz; Irız, Sibel; Alacacioglu, Ahmet

    2017-01-01

    The aim of this methodological study is to establish the validity and reliability of the Turkish version of "A Questionnaire for Measuring Attitudes toward Cancer (Cancer Stigma) - Patient version." The sample comprised oncology patients who had active cancer treatment. The construct validity was assessed using the confirmatory and exploratory factor analysis. The mean age of the participants was 54.9±12.3 years. In the confirmatory factor analysis, fit values were determined as comparative fit index = 0.93, goodness of fit index = 0.91, normed-fit index=0.91, and root mean square error of approximation RMSEA = 0.09 ( P Kaiser-Meyer-Olkin = 0.88, χ 2 = 1084.41, Df = 66, and Barletta's test P <0.000). The first factor was "impossibility of recovery and experience of social discrimination" and the second factor was "stereotypes of cancer patients." The two-factor structure accounted for 56.74% of the variance. The Cronbach's alpha value was determined as 0.88 for the two-factor scale. "A questionnaire for measuring attitudes toward cancer (cancer stigma) - Patient version" is a reliable and valid questionnaire to assess stigmatization of cancer in cancer patients.

  9. Reliability and validity of the upper-body dressing scale in Japanese patients with vascular dementia with hemiparesis.

    Science.gov (United States)

    Endo, Arisa; Suzuki, Makoto; Akagi, Atsumi; Chiba, Naoyuki; Ishizaka, Ikuyo; Matsunaga, Atsuhiko; Fukuda, Michinari

    2015-03-01

    The purpose of this study was to examine the reliability and validity of the Upper-body Dressing Scale (UBDS) for buttoned shirt dressing, which evaluates the learning process of new component actions of upper-body dressing in patients diagnosed with dementia and hemiparesis. This was a preliminary correlational study of concurrent validity and reliability in which 10 vascular dementia patients with hemiparesis were enrolled and assessed repeatedly by six occupational therapists by means of the UBDS and the dressing item of the Functional Independence Measure (FIM). Intraclass correlation coefficient was 0.97 for intra-rater reliability and 0.99 for inter-rater reliability. The level of correlation between UBDS score and FIM dressing item scores was -0.93. UBDS scores for paralytic hand passed into the sleeve and sleeve pulled up beyond the shoulder joint were worse than the scores for the other components of the task. The UBDS has good reliability and validity for vascular dementia patients with hemiparesis. Further research is needed to investigate the relation between UBDS score and the effect of intervention and to clarify sensitivity or responsiveness of the scale to clinical change. Copyright © 2014 John Wiley & Sons, Ltd.

  10. ASSESSING AND COMBINING RELIABILITY OF PROTEIN INTERACTION SOURCES

    Science.gov (United States)

    LEACH, SONIA; GABOW, AARON; HUNTER, LAWRENCE; GOLDBERG, DEBRA S.

    2008-01-01

    Integrating diverse sources of interaction information to create protein networks requires strategies sensitive to differences in accuracy and coverage of each source. Previous integration approaches calculate reliabilities of protein interaction information sources based on congruity to a designated ‘gold standard.’ In this paper, we provide a comparison of the two most popular existing approaches and propose a novel alternative for assessing reliabilities which does not require a gold standard. We identify a new method for combining the resultant reliabilities and compare it against an existing method. Further, we propose an extrinsic approach to evaluation of reliability estimates, considering their influence on the downstream tasks of inferring protein function and learning regulatory networks from expression data. Results using this evaluation method show 1) our method for reliability estimation is an attractive alternative to those requiring a gold standard and 2) the new method for combining reliabilities is less sensitive to noise in reliability assignments than the similar existing technique. PMID:17990508

  11. Optimizing delivery of a behavioral pain intervention in cancer patients using a sequential multiple assignment randomized trial SMART.

    Science.gov (United States)

    Kelleher, Sarah A; Dorfman, Caroline S; Plumb Vilardaga, Jen C; Majestic, Catherine; Winger, Joseph; Gandhi, Vicky; Nunez, Christine; Van Denburg, Alyssa; Shelby, Rebecca A; Reed, Shelby D; Murphy, Susan; Davidian, Marie; Laber, Eric B; Kimmick, Gretchen G; Westbrook, Kelly W; Abernethy, Amy P; Somers, Tamara J

    2017-06-01

    Pain is common in cancer patients and results in lower quality of life, depression, poor physical functioning, financial difficulty, and decreased survival time. Behavioral pain interventions are effective and nonpharmacologic. Traditional randomized controlled trials (RCT) test interventions of fixed time and dose, which poorly represent successive treatment decisions in clinical practice. We utilize a novel approach to conduct a RCT, the sequential multiple assignment randomized trial (SMART) design, to provide comparative evidence of: 1) response to differing initial doses of a pain coping skills training (PCST) intervention and 2) intervention dose sequences adjusted based on patient response. We also examine: 3) participant characteristics moderating intervention responses and 4) cost-effectiveness and practicality. Breast cancer patients (N=327) having pain (ratings≥5) are recruited and randomly assigned to: 1) PCST-Full or 2) PCST-Brief. PCST-Full consists of 5 PCST sessions. PCST-Brief consists of one 60-min PCST session. Five weeks post-randomization, participants re-rate their pain and are re-randomized, based on intervention response, to receive additional PCST sessions, maintenance calls, or no further intervention. Participants complete measures of pain intensity, interference and catastrophizing. Novel RCT designs may provide information that can be used to optimize behavioral pain interventions to be adaptive, better meet patients' needs, reduce barriers, and match with clinical practice. This is one of the first trials to use a novel design to evaluate symptom management in cancer patients and in chronic illness; if successful, it could serve as a model for future work with a wide range of chronic illnesses. Copyright © 2016. Published by Elsevier Inc.

  12. Validity and reliability of The Johns Hopkins Adapted Cognitive Exam for critically ill patients.

    Science.gov (United States)

    Lewin, John J; LeDroux, Shannon N; Shermock, Kenneth M; Thompson, Carol B; Goodwin, Haley E; Mirski, Erin A; Gill, Randeep S; Mirski, Marek A

    2012-01-01

    To validate The Johns Hopkins Adapted Cognitive Exam designed to assess and quantify cognition in critically ill patients. Prospective cohort study. Neurosciences, surgical, and medical intensive care units at The Johns Hopkins Hospital. One hundred six adult critically ill patients. One expert neurologic assessment and four measurements of the Adapted Cognitive Exam (all patients). Four measurements of the Folstein Mini-Mental State Examination in nonintubated patients only. Adapted Cognitive Exam and Mini-Mental State Examination were performed by 76 different raters. One hundred six patients were assessed, 46 intubated and 60 nonintubated, resulting in 424 Adapted Cognitive Exam and 240 Mini-Mental State Examination measurements. Criterion validity was assessed by comparing Adapted Cognitive Exam with a neurointensivist's assessment of cognitive status (ρ = 0.83, p validity was assessed by comparing Adapted Cognitive Exam with Mini-Mental State Examination in nonintubated patients (ρ = 0.81, p validity was assessed by surveying raters who used both the Adapted Cognitive Exam and Mini-Mental State Examination and indicated the Adapted Cognitive Exam was an accurate reflection of the patient's cognitive status, more sensitive a marker of cognition than the Mini-Mental State Examination, and easy to use. The Adapted Cognitive Exam demonstrated excellent interrater reliability (intraclass correlation coefficient = 0.997; 95% confidence interval 0.997-0.998) and interitem reliability of each of the five subscales of the Adapted Cognitive Exam and Mini-Mental State Examination (Cronbach's α: range for Adapted Cognitive Exam = 0.83-0.88; range for Mini-Mental State Examination = 0.72-0.81). The Adapted Cognitive Exam is the first valid and reliable examination for the assessment and quantification of cognition in critically ill patients. It provides a useful, objective tool that can be used by any member of the interdisciplinary critical care team to support

  13. Designing reliable supply chain network with disruption risk

    Directory of Open Access Journals (Sweden)

    Ali Bozorgi Amiri

    2013-01-01

    Full Text Available Although supply chains disruptions rarely occur, their negative effects are prolonged and severe. In this paper, we propose a reliable capacitated supply chain network design (RSCND model by considering random disruptions in both distribution centers and suppliers. The proposed model determines the optimal location of distribution centers (DC with the highest reliability, the best plan to assign customers to opened DCs and assigns opened DCs to suitable suppliers with lowest transportation cost. In this study, random disruption occurs at the location, capacity of the distribution centers (DCs and suppliers. It is assumed that a disrupted DC and a disrupted supplier may lose a portion of their capacities, and the rest of the disrupted DC's demand can be supplied by other DCs. In addition, we consider shortage in DCs, which can occur in either normal or disruption conditions and DCs, can support each other in such circumstances. Unlike other studies in the extent of literature, we use new approach to model the reliability of DCs; we consider a range of reliability instead of using binary variables. In order to solve the proposed model for real-world instances, a Non-dominated Sorting Genetic Algorithm-II (NSGA-II is applied. Preliminary results of testing the proposed model of this paper on several problems with different sizes provide seem to be promising.

  14. Systems reliability analysis for the national ignition facility

    International Nuclear Information System (INIS)

    Majumdar, K.C.; Annese, C.E.; MacIntyre, A.T.; Sicherman, A.

    1996-01-01

    A Reliability, Availability and Maintainability (RAM) analysis was initiated for the National Ignition Facility (NIF). The NIF is an inertial confinement fusion research facility designed to achieve controlled thermonuclear reaction; the preferred site for the NIF is the Lawrence Livermore National Laboratory (LLNL). The NIF RAM analysis has three purposes: (1) to allocate top level reliability and availability goals for the systems, (2) to develop an operability model for optimum maintainability, and (3) to determine the achievability of the allocated goals of the RAM parameters for the NIF systems and the facility operation as a whole. An allocation model assigns the reliability and availability goals for front line and support systems by a top-down approach; reliability analysis uses a bottom-up approach to determine the system reliability and availability from component level to system level

  15. DNA barcoding for species assignment: the case of Mediterranean marine fishes.

    Directory of Open Access Journals (Sweden)

    Monica Landi

    Full Text Available DNA barcoding enhances the prospects for species-level identifications globally using a standardized and authenticated DNA-based approach. Reference libraries comprising validated DNA barcodes (COI constitute robust datasets for testing query sequences, providing considerable utility to identify marine fish and other organisms. Here we test the feasibility of using DNA barcoding to assign species to tissue samples from fish collected in the central Mediterranean Sea, a major contributor to the European marine ichthyofaunal diversity.A dataset of 1278 DNA barcodes, representing 218 marine fish species, was used to test the utility of DNA barcodes to assign species from query sequences. We tested query sequences against 1 a reference library of ranked DNA barcodes from the neighbouring North East Atlantic, and 2 the public databases BOLD and GenBank. In the first case, a reference library comprising DNA barcodes with reliability grades for 146 fish species was used as diagnostic dataset to screen 486 query DNA sequences from fish specimens collected in the central basin of the Mediterranean Sea. Of all query sequences suitable for comparisons 98% were unambiguously confirmed through complete match with reference DNA barcodes. In the second case, it was possible to assign species to 83% (BOLD-IDS and 72% (GenBank of the sequences from the Mediterranean. Relatively high intraspecific genetic distances were found in 7 species (2.2%-18.74%, most of them of high commercial relevance, suggesting possible cryptic species.We emphasize the discriminatory power of COI barcodes and their application to cases requiring species level resolution starting from query sequences. Results highlight the value of public reference libraries of reliability grade-annotated DNA barcodes, to identify species from different geographical origins. The ability to assign species with high precision from DNA samples of disparate quality and origin has major utility in several

  16. Reliability of sonographic assessment of tendinopathy in tennis elbow.

    Science.gov (United States)

    Poltawski, Leon; Ali, Syed; Jayaram, Vijay; Watson, Tim

    2012-01-01

    To assess the reliability and compute the minimum detectable change using sonographic scales to quantify the extent of pathology and hyperaemia in the common extensor tendon in people with tennis elbow. The lateral elbows of 19 people with tennis elbow were assessed sonographically twice, 1-2 weeks apart. Greyscale and power Doppler images were recorded for subsequent rating of abnormalities. Tendon thickening, hypoechogenicity, fibrillar disruption and calcification were each rated on four-point scales, and scores were summed to provide an overall rating of structural abnormality; hyperaemia was scored on a five point scale. Inter-rater reliability was established using the intraclass correlation coefficient (ICC) to compare scores assigned independently to the same set of images by a radiologist and a physiotherapist with training in musculoskeletal imaging. Test-retest reliability was assessed by comparing scores assigned by the physiotherapist to images recorded at the two sessions. The minimum detectable change (MDC) was calculated from the test-retest reliability data. ICC values for inter-rater reliability ranged from 0.35 (95% CI: 0.05, 0.60) for fibrillar disruption to 0.77 (0.55, 0.88) for overall greyscale score, and 0.89 (0.79, 0.95) for hyperaemia. Test-retest reliability ranged from 0.70 (0.48, 0.84) for tendon thickening to 0.82 (0.66, 0.90) for overall greyscale score and 0.86 (0.73, 0.93) for calcification. The MDC for the greyscale total score was 2.0/12 and for the hyperaemia score was 1.1/5. The sonographic scoring system used in this study may be used reliably to quantify tendon abnormalities and change over time. A relatively inexperienced imager can conduct the assessment and use the rating scales reliably.

  17. Interrater reliability of the Volume-Viscosity Swallow Test; screening for dysphagia among hospitalized elderly medical patients

    DEFF Research Database (Denmark)

    Jørgensen, Lise Walther; Søndergaard, Kasper; Melgaard, Dorte

    2017-01-01

    Background: Oropharyngeal dysphagia (OD) is prevalent among medical and geriatric patients admitted due to acute illness and it is associated with malnutrition, increased length of stay and increased mortality. A valid and reliable bedside screening test for patients at risk of OD is essential...... in order to detect patients in need of further assessment. The Volume-Viscosity Swallow Test (V-VST) has been shown to be a valid screening test for OD in mixed outpatient populations. However, as reliability of the test has yet to be investigated in a population of medical and geriatric patients admitted...... skilled occupational therapists examined an unselected group of 110 patients admitted to geriatric or medical wards. In an overall agreement phase raters reached ≥80% agreement before data collection phase was commenced. The V-VST was applied to patients twice within maximum one hour by raters who...

  18. Grouping puts figure-ground assignment in context by constraining propagation of edge assignment.

    Science.gov (United States)

    Brooks, Joseph L; Brook, Joseph L; Driver, Jon

    2010-05-01

    Figure-ground organization involves the assignment of edges to a figural shape on one or the other side of each dividing edge. Established visual cues for edge assignment primarily concern relatively local rather than contextual factors. In the present article, we show that an assignment for a locally unbiased edge can be affected by an assignment of a remote contextual edge that has its own locally biased assignment. We find that such propagation of edge assignment from the biased remote context occurs only when the biased and unbiased edges are grouped. This new principle, whereby grouping constrains the propagation of figural edge assignment, emerges from both subjective reports and an objective short-term edge-matching task. It generalizes from moving displays involving grouping by common fate and collinearity, to static displays with grouping by similarity of edge-contrast polarity, or apparent occlusion. Our results identify a new contextual influence on edge assignment. They also identify a new mechanistic relation between grouping and figure-ground processes, whereby grouping between remote elements can constrain the propagation of edge assignment between those elements. Supplemental materials for this article may be downloaded from http://app.psychonomic-journals.org/content/supplemental.

  19. Secure Cooperative Spectrum Sensing for the Cognitive Radio Network Using Nonuniform Reliability

    Directory of Open Access Journals (Sweden)

    Muhammad Usman

    2014-01-01

    Full Text Available Both reliable detection of the primary signal in a noisy and fading environment and nullifying the effect of unauthorized users are important tasks in cognitive radio networks. To address these issues, we consider a cooperative spectrum sensing approach where each user is assigned nonuniform reliability based on the sensing performance. Users with poor channel or faulty sensor are assigned low reliability. The nonuniform reliabilities serve as identification tags and are used to isolate users with malicious behavior. We consider a link layer attack similar to the Byzantine attack, which falsifies the spectrum sensing data. Three different strategies are presented in this paper to ignore unreliable and malicious users in the network. Considering only reliable users for global decision improves sensing time and decreases collisions in the control channel. The fusion center uses the degree of reliability as a weighting factor to determine the global decision in scheme I. Schemes II and III consider the unreliability of users, which makes the computations even simpler. The proposed schemes reduce the number of sensing reports and increase the inference accuracy. The advantages of our proposed schemes over conventional cooperative spectrum sensing and the Chair-Varshney optimum rule are demonstrated through simulations.

  20. Validity and reliability of Turkish Caregiver Burden Scale among family caregivers of haemodialysis patients.

    Science.gov (United States)

    Cil Akinci, Ayse; Pinar, Rukiye

    2014-02-01

    To investigate the validity and reliability of the Caregiver Burden Scale in family members who provide primary care for haemodialysis patients. In Turkey, there is a need for a multi-dimensional instrument to evaluate the caregiver burden in people who provide care for patients with chronic diseases. A methodological study. The study sample consisted of 161 family members who provide primary care for haemodialysis patients. The forward-backward translation method was used to develop the Turkish Caregiver Burden Scale. The reliability was based on internal consistency investigated by Cronbach's alpha and item-total correlation. The factorial construct validity of the scale was tested with confirmatory factor analysis. By means of convergent and divergent validity, correlation between Caregiver Burden Scale and 36-Item Short Form Health Survey (SF-36) and correlation between Caregiver Burden Scale and the Maslach Burnout Scale were investigated. Cronbach's alpha and item-total correlations results suggested that there was good internal reliability. We found five underlying factors similar to original Scale's five-factor solution. The confirmatory factor analysis five-factor model represented an acceptable fit. Factor loadings were significant, with standardised loadings ranging from 0·43-0·81. By means of divergent validity, all sub-dimension scores and the total score of the Caregiver Burden Scale were negatively correlated with the SF-36, whereas there was a positive correlation with the emotional exhaustion and depersonalisation subscales of the Maslach Burnout Scale as expected. These results suggest that the Caregiver Burden Scale is a reliable and valid instrument which can be used with confidence in Turkish caregivers for haemodialysis patients to screen caregiver burden. The burden experienced by people who provide care for patients with chronic diseases can be evaluated with the Caregiver Burden Scale. Additionally, the Caregiver Burden Scale can be used

  1. Validity and reliability of the Greek version of the xerostomia questionnaire in head and neck cancer patients.

    Science.gov (United States)

    Memtsa, Pinelopi Theopisti; Tolia, Maria; Tzitzikas, Ioannis; Bizakis, Ioannis; Pistevou-Gombaki, Kyriaki; Charalambidou, Martha; Iliopoulou, Chrysoula; Kyrgias, George

    2017-03-01

    Xerostomia after radiation therapy for head and neck (H&N) cancer has serious effects on patients' quality of life. The purpose of this study was to validate the Greek version of the self-reported eight-item xerostomia questionnaire (XQ) in patients treated with radiotherapy for H&N cancer. The XQ was translated into Greek and administered to 100 XQ patients. An exploratory factor analysis was performed. Reliability measures were calculated. Several types of validity were evaluated. The observer-rated scoring system was also used. The mean XQ value was 41.92 (SD 22.71). Factor analysis revealed the unidimensional nature of the questionnaire. High reliability measures (ICC, Cronbach's α, Pearson coefficients) were obtained. Patients differed statistically significantly in terms of XQ score, depending on the RTOG/EORTC classification. The Greek version of XQ is valid and reliable. Its score is well related to observer's findings and it can be used to evaluate the impact of radiation therapy on the subjective feeling of xerostomia.

  2. The hospital anxiety and depression scale--dimensionality, reliability and construct validity among cognitively intact nursing home patients.

    Science.gov (United States)

    Haugan, Gørill; Drageset, Jorunn

    2014-08-01

    Depression and anxiety are particularly common among individuals living in long-term care facilities. Therefore, access to a valid and reliable measure of anxiety and depression among nursing home patients is highly warranted. To investigate the dimensionality, reliability and construct validity of the Hospital Anxiety and Depression scale (HADS) in a cognitively intact nursing home population. Cross-sectional data were collected from two samples; 429 cognitively intact nursing home patients participated, representing 74 different Norwegian nursing homes. Confirmative factor analyses and correlations with selected constructs were used. The two-factor model provided a good fit in Sample1, revealing a poorer fit in Sample2. Good-acceptable measurement reliability was demonstrated, and construct validity was supported. Using listwise deletion the sample sizes were 227 and 187, for Sample1 and Sample2, respectively. Greater sample sizes would have strengthen the statistical power in the tests. The researchers visited the participants to help fill in the questionnaires; this might have introduced some bias into the respondents׳ reporting. The 14 HADS items were part of greater questionnaires. Thus, frail, older NH patients might have tired during the interview causing a possible bias. Low reliability for depression was disclosed, mainly resulting from three items appearing to be inappropriate indicators for depression in this population. Further research is needed exploring which items might perform as more reliably indicators for depression among nursing home patients. Copyright © 2014 Elsevier B.V. All rights reserved.

  3. FLEET ASSIGNMENT MODELLING

    Directory of Open Access Journals (Sweden)

    2016-01-01

    Full Text Available The article is devoted to the airline scheduling process and methods of its modeling. This article describes the main stages of airline scheduling process (scheduling, fleet assignment, revenue management, operations, their features and interactions. The main part of scheduling process is fleet assignment. The optimal solution of the fleet assignment problem enables airlines to increase their incomes up to 3 % due to quality improving of connections and execution of the planned number of flights operated by less number of aircraft than usual or planned earlier. Fleet assignment of scheduling process is examined and Conventional Leg-Based Fleet Assignment Model is analyzed. Finally strong and weak aspects of the model (SWOT are released and applied. The article gives a critical analysis of FAM model, with the purpose of identi- fying possible options and constraints of its use (for example, in cases of short-term and long-term planning, changing the schedule or replacing the aircraft, as well as possible ways to improve the model.

  4. [Rapid assessment of critical quality attributes of Chinese materia medica (II): strategy of NIR assignment].

    Science.gov (United States)

    Pei, Yan-Ling; Wu, Zhi-Sheng; Shi, Xin-Yuan; Zhou, Lu-Wei; Qiao, Yan-Jiang

    2014-09-01

    The present paper firstly reviewed the research progress and main methods of NIR spectral assignment coupled with our research results. Principal component analysis was focused on characteristic signal extraction to reflect spectral differences. Partial least squares method was concerned with variable selection to discover characteristic absorption band. Two-dimensional correlation spectroscopy was mainly adopted for spectral assignment. Autocorrelation peaks were obtained from spectral changes, which were disturbed by external factors, such as concentration, temperature and pressure. Density functional theory was used to calculate energy from substance structure to establish the relationship between molecular energy and spectra change. Based on the above reviewed method, taking a NIR spectral assignment of chlorogenic acid as example, a reliable spectral assignment for critical quality attributes of Chinese materia medica (CMM) was established using deuterium technology and spectral variable selection. The result demonstrated the assignment consistency according to spectral features of different concentrations of chlorogenic acid and variable selection region of online NIR model in extract process. Although spectral assignment was initial using an active pharmaceutical ingredient, it is meaningful to look forward to the futurity of the complex components in CMM. Therefore, it provided methodology for NIR spectral assignment of critical quality attributes in CMM.

  5. Reliability and validity study of a tool to measure cancer stigma: Patient version

    Directory of Open Access Journals (Sweden)

    Medine Yilmaz

    2017-01-01

    Full Text Available Objective: The aim of this methodological study is to establish the validity and reliability of the Turkish version of “A Questionnaire for Measuring Attitudes toward Cancer (Cancer Stigma - Patient version.” Methods: The sample comprised oncology patients who had active cancer treatment. The construct validity was assessed using the confirmatory and exploratory factor analysis. Results: The mean age of the participants was 54.9±12.3 years. In the confirmatory factor analysis, fit values were determined as comparative fit index = 0.93, goodness of fit index = 0.91, normed-fit index=0.91, and root mean square error of approximation RMSEA = 0.09 (P<0.05 (Kaiser–Meyer–Olkin = 0.88, χ2 = 1084.41, Df = 66, and Barletta's test P<0.000. The first factor was “impossibility of recovery and experience of social discrimination” and the second factor was “stereotypes of cancer patients.” The two-factor structure accounted for 56.74% of the variance. The Cronbach's alpha value was determined as 0.88 for the two-factor scale. Conclusions: “A questionnaire for measuring attitudes toward cancer (cancer stigma - Patient version” is a reliable and valid questionnaire to assess stigmatization of cancer in cancer patients.

  6. Quality of nursing intensity data: inter-rater reliability of the patient classification after two decades in clinical use.

    Science.gov (United States)

    Liljamo, Pia; Kinnunen, Ulla-Mari; Ohtonen, Pasi; Saranto, Kaija

    2017-09-01

    The aim of this study was to measure the inter-rater reliability of the Oulu Patient Classification and to discuss existing methods of reliability testing. The Oulu Patient Classification, part of the RAFAELA ® System, has been developed to assist nursing managers with the proper allocation of nursing resources. Due to the increased intensity of inpatient care during recent years, there is a need for the reliability testing of the classification, which has been in clinical use for 20 years. Retrospective statistical study. To test inter-rater reliability, a pair of nurses classified the same patients, without knowledge of each other's ratings, as a part of annually conducted standardization. Data on the parallel classifications (n = 19,997) was obtained from inpatient units (n = 32) with different specialties at a university hospital in Finland during 2010-2015. Parallel classification practices were also analysed. The reliability of the overall classification and its subareas were calculated using suitable statistical coefficients. Inter-rater reliability coefficients were a reliable or almost perfect means of considering the nursing intensity category and various practices, but there were detectable differences between subareas. The lowest agreement levels occurred in the subareas 'Planning and Coordination of Nursing Care' and 'Guiding of Care/Continued Care and Emotional Support'. There is a need to develop the descriptions of subareas and to clarify the related concepts. Precise nursing documentation can promote a high level of agreement and reliable results. The traditional overall proportion of agreement does not provide an adequate picture of reliability - weighted kappa coefficients should be used instead. © 2017 John Wiley & Sons Ltd.

  7. Test-retest reliability of the Danish Adult Reading Test in patients with comorbid psychosis and cannabis-use disorder

    DEFF Research Database (Denmark)

    Hjorthøj, Carsten Rygaard; Vesterager, Lone; Nordentoft, Merete

    2013-01-01

    Background: The New Adult Reading Test is a common instrument for assessing pre-morbid IQ for patients with, for instance, schizophrenia. However, test-retest reliability has not been established for patients dually diagnosed with psychosis and substance use disorder. Furthermore, test......-retest reliability of the Danish adaptation has never been established in any population. Aims: To determine the test-retest reliability of the Danish Adult Reading Test (DART) (adapted from the National Adult Reading Test, NART) for patients dually diagnosed with psychosis and cannabis-use disorder. Methods......: This was a secondary analysis of the CapOpus randomized trial. As part of the trial, 103 patients were randomized, and completed the DART up to three times. Pearson's r and pairwise t-tests were calculated. Results: DART score was independent of randomization, cannabis-use frequency and psychopathology. Scores...

  8. Emergency Severity Index version 4: a valid and reliable tool in pediatric emergency department triage.

    Science.gov (United States)

    Green, Nicole A; Durani, Yamini; Brecher, Deena; DePiero, Andrew; Loiselle, John; Attia, Magdy

    2012-08-01

    The Emergency Severity Index version 4 (ESI v.4) is the most recently implemented 5-level triage system. The validity and reliability of this triage tool in the pediatric population have not been extensively established. The goals of this study were to assess the validity of ESI v.4 in predicting hospital admission, emergency department (ED) length of stay (LOS), and number of resources utilized, as well as its reliability in a prospective cohort of pediatric patients. The first arm of the study was a retrospective chart review of 780 pediatric patients presenting to a pediatric ED to determine the validity of ESI v.4. Abstracted data included acuity level assigned by the triage nurse using ESI v.4 algorithm, disposition (admission vs discharge), LOS, and number of resources utilized in the ED. To analyze the validity of ESI v.4, patients were divided into 2 groups for comparison: higher-acuity patients (ESI levels 1, 2, and 3) and lower-acuity patients (ESI levels 4 and 5). Pearson χ analysis was performed for categorical variables. For continuous variables, we conducted a comparison of means based on parametric distribution of variables. The second arm was a prospective cohort study to determine the interrater reliability of ESI v.4 among and between pediatric triage (PT) nurses and pediatric emergency medicine (PEM) physicians. Three raters (2 PT nurses and 1 PEM physician) independently assigned triage scores to 100 patients; k and interclass correlation coefficient were calculated among PT nurses and between the primary PT nurses and physicians. In the validity arm, the distribution of ESI score levels among the 780 cases are as follows: ESI 1: 2 (0.25%); ESI 2: 73 (9.4%); ESI 3: 289 (37%); ESI 4: 251 (32%); and ESI 5: 165 (21%). Hospital admission rates by ESI level were 1: 100%, 2: 42%, 3: 14.9%, 4: 1.2%, and 5: 0.6%. The admission rate of the higher-acuity group (76/364, 21%) was significantly greater than the lower-acuity group (4/415, 0.96%), P group was

  9. Reliability and validity of the visual analogue scale for disability in patients with chronic musculoskeletal pain

    NARCIS (Netherlands)

    Boonstra, Anne M.; Schiphorst Preuper, Henrica R.; Reneman, Michiel F.; Posthumus, Jitze B.; Stewart, Roy E.

    To determine the reliability and concurrent validity of a visual analogue scale (VAS) for disability as a single-item instrument measuring disability in chronic pain patients was the objective of the study. For the reliability study a test-retest design and for the validity study a cross-sectional

  10. Synthetical analysis of the spin assignment for the superdeformed bands in A≅190 region

    International Nuclear Information System (INIS)

    Di Yaomin

    2002-01-01

    The spin assignment for the superdeformed bands of even-even nuclei in A ≅190 region is given by means of using the method of synthetical analysis. The I( I + 1) expression is used to fit the experimental data of the transition γ energies. In contrast to other procedure, the convergence process of the series expansions is put stress upon, whereas taking how many terms exactly in the expression does not emphasized. Moreover as well as the method of fitting the physical quantity, by use of these series expansions the moment of inertia of band heads is also calculated and then the systematics is used for the spin assignments. In practice, when the experimental data is abundant the systematics of the moment of inertia of band heads is more efficient than the method of fitting the physical quantity in the spin assignment. As for a few bands which spin assignment is difficult, the deviation from the typical rotational bands must be considered, which may be judged easily from the second class of moment of inertia of the bands. Finally the results of the spin assignment and the comparison with other literature are presented. These results should be more reliable

  11. Standardized Patients Provide a Reliable Assessment of Athletic Training Students' Clinical Skills

    Science.gov (United States)

    Armstrong, Kirk J.; Jarriel, Amanda J.

    2016-01-01

    Context: Providing students reliable objective feedback regarding their clinical performance is of great value for ongoing clinical skill assessment. Since a standardized patient (SP) is trained to consistently portray the case, students can be assessed and receive immediate feedback within the same clinical encounter; however, no research, to our…

  12. Gender identity and gender role orientation in female assigned patients with disorders of sex development.

    Science.gov (United States)

    Mattila, Aino K; Fagerholm, Riitta; Santtila, Pekka; Miettinen, Päivi J; Taskinen, Seppo

    2012-11-01

    Gender identity and gender role orientation were assessed in 24 female assigned patients with disorders of sex development. A total of 16 patients were prenatally exposed to androgens, of whom 15 had congenital adrenal hyperplasia and 1 was virilized due to maternal tumor. Eight patients had 46,XY karyotype, of whom 5 had partial and 3 had complete androgen insensitivity syndrome. Gender identity was measured by the 27-item Gender Identity/Gender Dysphoria Questionnaire for Adolescents and Adults with 167 female medical students as controls, and gender role was assessed by the femininity and masculinity subscales of the 30-item Bem Sex Role Inventory with 104 female and 64 male medical students as controls. No patient reached the cutoff for gender identity disorder on the Gender Identity/Gender Dysphoria Questionnaire for Adolescents and Adults. However, patients with 46,XY karyotype demonstrated a somewhat more conflicted gender identity, although the overall differences were relatively small. As to gender role orientation, patients with complete androgen insensitivity syndrome had high scores on the femininity and masculinity scales of the Bem Sex Role Inventory, which made them the most androgynous group. Our findings, although clinically not clear cut, suggest that patients with disorders of sex development are a heterogeneous group regarding gender identity and gender role outcomes, and that this issue should be discussed with the family when treatment plans are made. Copyright © 2012 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  13. Assigning clinical codes with data-driven concept representation on Dutch clinical free text.

    Science.gov (United States)

    Scheurwegs, Elyne; Luyckx, Kim; Luyten, Léon; Goethals, Bart; Daelemans, Walter

    2017-05-01

    Clinical codes are used for public reporting purposes, are fundamental to determining public financing for hospitals, and form the basis for reimbursement claims to insurance providers. They are assigned to a patient stay to reflect the diagnosis and performed procedures during that stay. This paper aims to enrich algorithms for automated clinical coding by taking a data-driven approach and by using unsupervised and semi-supervised techniques for the extraction of multi-word expressions that convey a generalisable medical meaning (referred to as concepts). Several methods for extracting concepts from text are compared, two of which are constructed from a large unannotated corpus of clinical free text. A distributional semantic model (i.c. the word2vec skip-gram model) is used to generalize over concepts and retrieve relations between them. These methods are validated on three sets of patient stay data, in the disease areas of urology, cardiology, and gastroenterology. The datasets are in Dutch, which introduces a limitation on available concept definitions from expert-based ontologies (e.g. UMLS). The results show that when expert-based knowledge in ontologies is unavailable, concepts derived from raw clinical texts are a reliable alternative. Both concepts derived from raw clinical texts perform and concepts derived from expert-created dictionaries outperform a bag-of-words approach in clinical code assignment. Adding features based on tokens that appear in a semantically similar context has a positive influence for predicting diagnostic codes. Furthermore, the experiments indicate that a distributional semantics model can find relations between semantically related concepts in texts but also introduces erroneous and redundant relations, which can undermine clinical coding performance. Copyright © 2017. Published by Elsevier Inc.

  14. Accuracy of administratively-assigned ancestry for diverse populations in an electronic medical record-linked biobank.

    Directory of Open Access Journals (Sweden)

    Jacob B Hall

    Full Text Available Recently, the development of biobanks linked to electronic medical records has presented new opportunities for genetic and epidemiological research. Studies based on these resources, however, present unique challenges, including the accurate assignment of individual-level population ancestry. In this work we examine the accuracy of administratively-assigned race in diverse populations by comparing assigned races to genetically-defined ancestry estimates. Using 220 ancestry informative markers, we generated principal components for patients in our dataset, which were used to cluster patients into groups based on genetic ancestry. Consistent with other studies, we find a strong overall agreement (Kappa  = 0.872 between genetic ancestry and assigned race, with higher rates of agreement for African-descent and European-descent assignments, and reduced agreement for Hispanic, East Asian-descent, and South Asian-descent assignments. These results suggest caution when selecting study samples of non-African and non-European backgrounds when administratively-assigned race from biobanks is used.

  15. Simulated patient training: Using inter-rater reliability to evaluate simulated patient consistency in nursing education.

    Science.gov (United States)

    MacLean, Sharon; Geddes, Fiona; Kelly, Michelle; Della, Phillip

    2018-03-01

    Simulated patients (SPs) are frequently used for training nursing students in communication skills. An acknowledged benefit of using SPs is the opportunity to provide a standardized approach by which participants can demonstrate and develop communication skills. However, relatively little evidence is available on how to best facilitate and evaluate the reliability and accuracy of SPs' performances. The aim of this study is to investigate the effectiveness of an evidenced based SP training framework to ensure standardization of SPs. The training framework was employed to improve inter-rater reliability of SPs. A quasi-experimental study was employed to assess SP post-training understanding of simulation scenario parameters using inter-rater reliability agreement indices. Two phases of data collection took place. Initially a trial phase including audio-visual (AV) recordings of two undergraduate nursing students completing a simulation scenario is rated by eight SPs using the Interpersonal Communication Assessments Scale (ICAS) and Quality of Discharge Teaching Scale (QDTS). In phase 2, eight SP raters and four nursing faculty raters independently evaluated students' (N=42) communication practices using the QDTS. Intraclass correlation coefficients (ICC) were >0.80 for both stages of the study in clinical communication skills. The results support the premise that if trained appropriately, SPs have a high degree of reliability and validity to both facilitate and evaluate student performance in nurse education. Crown Copyright © 2018. Published by Elsevier Ltd. All rights reserved.

  16. Reliability and measurement error of sagittal spinal motion parameters in 220 patients with chronic low back pain using a three-dimensional measurement device.

    Science.gov (United States)

    Mieritz, Rune M; Bronfort, Gert; Jakobsen, Markus D; Aagaard, Per; Hartvigsen, Jan

    2014-09-01

    A basic premise for any instrument measuring spinal motion is that reliable outcomes can be obtained on a relevant sample under standardized conditions. The purpose of this study was to assess the overall reliability and measurement error of regional spinal sagittal plane motion in patients with chronic low back pain (LBP), and then to evaluate the influence of body mass index, examiner, gender, stability of pain, and pain distribution on reliability and measurement error. This study comprises a test-retest design separated by 7 to 14 days. The patient cohort consisted of 220 individuals with chronic LBP. Kinematics of the lumbar spine were sampled during standardized spinal extension-flexion testing using a 6-df instrumented spatial linkage system. Test-retest reliability and measurement error were evaluated using interclass correlation coefficients (ICC(1,1)) and Bland-Altman limits of agreement (LOAs). The overall test-retest reliability (ICC(1,1)) for various motion parameters ranged from 0.51 to 0.70, and relatively wide LOAs were observed for all parameters. Reliability measures in patient subgroups (ICC(1,1)) ranged between 0.34 and 0.77. In general, greater (ICC(1,1)) coefficients and smaller LOAs were found in subgroups with patients examined by the same examiner, patients with a stable pain level, patients with a body mass index less than below 30 kg/m(2), patients who were men, and patients in the Quebec Task Force classifications Group 1. This study shows that sagittal plane kinematic data from patients with chronic LBP may be sufficiently reliable in measurements of groups of patients. However, because of the large LOAs, this test procedure appears unusable at the individual patient level. Furthermore, reliability and measurement error varies substantially among subgroups of patients. Copyright © 2014 Elsevier Inc. All rights reserved.

  17. Reliability of widefield nailfold capillaroscopy and video capillaroscopy in the assessment of patients with Raynaud’s phenomenon.

    Science.gov (United States)

    Sekiyama, Juliana Y; Camargo, Cintia Z; Eduardo, Luís; Andrade, C; Kayser, Cristiane

    2013-11-01

    To analyze the diagnostic performance and reliability of different parameters evaluated by widefield nailfold capillaroscopy (NFC) with those obtained by video capillaroscopy in patients with Raynaud’s phenomenon (RP). Two hundred fifty-two individuals were assessed, including 101 systemic sclerosis (SSc; scleroderma) patients,61 patients with undifferentiated connective tissue disease, 37 patients with primary RP, and 53 controls. Widefield NFC was performed using a stereomicroscope under 10–25 x magnification and direct measurement of all parameters. Video capillaroscopy was performed under 200 x magnification, with the acquirement of 32 images per individual (4 fields per finger in 8 fingers). The following parameters were analyzed in 8 fingers of the hands (excluding thumbs) by both methods: number of capillaries/mm, number of enlarged and giant capillaries, microhemorrhages, and avascular score.Intra- and interobserver reliability was evaluated by performing both examinations in 20 individuals on 2 different days and by 2 long-term experienced observers. There was a significant correlation (P capillaroscopy in the comparison of all parameters. Kappa values and intraclass correlation coefficient analysis showed excellent intra- and interobserver reproducibility for all parameters evaluated by widefield NFC and video capillaroscopy. Bland-Altman analysis showed high agreement of all parameters evaluated in both methods. According to receiver operating characteristic curve analysis, both methods showed a similar performance in discriminating SSc patients from controls. Widefield NFC and video capillaroscopy are reliable and accurate methods and can be used equally for assessing peripheral microangiopathy in RP and SSc patients. Nonetheless, the high reliability obtained may not be similar for less experienced examiners.

  18. Reliability of an anamnestic questionnaire for the diagnosis of benign paroxysmal positional vertigo in the elderly.

    Science.gov (United States)

    Lapenna, Ruggero; Faralli, Mario; Del Zompo, Maria Rita; Cipriani, Laura; Mobaraki, Puya Dehgani; Ricci, Giampietro

    2016-10-01

    There is common agreement in the literature that it can result in an underestimation of benign paroxysmal positional vertigo (BPPV) in the elderly. The aim of this work was to analyze the role of anamnesis in the diagnosis of BPPV in patients of different ages through the development and validation of a scored questionnaire. The questionnaire is based on the presence/absence of six typical anamnestic features of BPPV. The Mini-Mental State Exam (MMS) was also administered to patients over 65 years of age. Bedsides, examination for BPPV was then carried out, assigning the outcome of the questionnaire and eventual MMS to the final diagnosis for each patient. The sensitivity and specificity of the questionnaire for high scores (>8) were found to be, respectively, 86 % and 80 % in all patients, 94 and 71 % in those under 65 years of age, 78 and 90 % in patients over 65, and, in particular, 63 and 83 % in those with MMS >24 and 100 and 100 % in those with MMS ≤24. The reliability and average score of the questionnaire were statistically significantly lower in the group of elderly patients without cognitive deficits. The lower reliability of the questionnaire in the geriatric population, rather than the presence of cognitive deterioration, seems to correlate with other comorbidities or simply to a lower mobility of the head triggering positional symptoms. The use of the questionnaire could however reduce the risk of a missed diagnosis of BPPV given its good reliability across all ages.

  19. The modified patient enablement instrument: a Portuguese cross-cultural adaptation, validity and reliability study.

    Science.gov (United States)

    Remelhe, Mafalda; Teixeira, Pedro M; Lopes, Irene; Silva, Luís; Correia de Sousa, Jaime

    2017-01-12

    Enabling patients with asthma to obtain the knowledge, confidence and skills they need in order to assume a major role in the management of their disease is cost effective. It should be an integral part of any plan for long-term control of asthma. The modified Patient Enablement Instrument (mPEI) is an easily administered questionnaire that was adapted in the United Kingdom to measure patient enablement in asthma, but its applicability in Portugal is not known. Validity and reliability of questionnaires should be tested before use in settings different from those of the original version. The purpose of this study was to test the applicability of the mPEI to Portuguese asthma patients after translation and cross-cultural adaptation, and to verify the structural validity, internal consistency and reproducibility of the instrument. The mPEI was translated to Portuguese and back translated to English. Its content validity was assessed by a debriefing interview with 10 asthma patients. The translated instrument was then administered to a random sample of 142 patients with persistent asthma. Structural validity and internal consistency were assessed. For reproducibility analysis, 86 patients completed the instrument again 7 days later. Item-scale correlations and exploratory factor analysis were used to assess structural validity. Cronbach's alpha was used to test internal consistency, and the intra-class correlation coefficient was used for the analysis of reproducibility. All items of the Portuguese version of the mPEI were found to be equivalent to the original English version. There were strong item-scale correlations that confirmed construct validity, with a one component structure and good internal consistency (Cronbach's alpha >0.8) as well as high test-retest reliability (ICC=0.85). The mPEI showed sound psychometric properties for the evaluation of enablement in patients with asthma making it a reliable instrument for use in research and clinical practice in

  20. Long-term risk of carotid restenosis in patients randomly assigned to endovascular treatment or endarterectomy in the Carotid and Vertebral Artery Transluminal Angioplasty Study (CAVATAS): long-term follow-up of a randomised trial.

    LENUS (Irish Health Repository)

    Bonati, Leo H

    2009-10-01

    In the Carotid and Vertebral Artery Transluminal Angioplasty Study (CAVATAS), early recurrent carotid stenosis was more common in patients assigned to endovascular treatment than it was in patients assigned to endarterectomy (CEA), raising concerns about the long-term effectiveness of endovascular treatment. We aimed to investigate the long-term risks of restenosis in patients included in CAVATAS.

  1. Reliability and validity of the Treatment Satisfaction Questionnaire for Medication among Portuguese-speaking Brazilian patients with hypertension.

    Science.gov (United States)

    Sauer Liberato, Ana Carolina; Cunha Matheus Rodrigues, Roberta; Kim, MyoungJin; Mallory, Caroline

    2016-07-01

    This study examined the reliability and validity of the Brazilian Portuguese version of the Treatment Satisfaction Questionnaire for Medication (version 1.4) among patients with hypertension. Understanding the patient experience with treatment satisfaction will contribute to improved medication adherence and control of hypertension. Hypertension is a serious problem in Brazil that is associated with chronic illness controlled, in part, by consistent adherence to medications. Patient satisfaction with medication treatment is associated with adherence to medication. The Treatment Satisfaction Questionnaire for Medication (version 1.4) is a promising instrument for measuring medication; however, to date there has been no report of the reliability and validity of the instrument with Portuguese-speaking adults with hypertension in Brazil. Cross-sectional descriptive exploratory study. A convenience sample of 300 patients with hypertension in an outpatient setting in the southeast region of São Paulo state in Brazil completed the Treatment Satisfaction Questionnaire for Medication (version 1.4). The instrument, comprised of four subscales, was evaluated for reliability using correlation analyses and internal consistency. Confirmatory factor analysis was used to determine factorial validity. Correlational analyses, internal consistency (Cronbach's alpha) and hierarchical confirmatory factor analysis demonstrate adequate support for the four-factor dimensionality, reliability and factorial validity of the Treatment Satisfaction Questionnaire for Medication (version 1.4). This study provides modest evidence for internal consistency and factorial validity of the Treatment Satisfaction Questionnaire for Medication (version 1.4) in Portuguese-speaking adult Brazilians with hypertension. Future testing should focus on extending reliability testing, discriminant validity and potential translation and literacy issues in this population. Within known limitations, clinicians will

  2. Inter-rater reliability of three standardized functional tests in patients with low back pain

    Science.gov (United States)

    Tidstrand, Johan; Horneij, Eva

    2009-01-01

    Background Of all patients with low back pain, 85% are diagnosed as "non-specific lumbar pain". Lumbar instability has been described as one specific diagnosis which several authors have described as delayed muscular responses, impaired postural control as well as impaired muscular coordination among these patients. This has mostly been measured and evaluated in a laboratory setting. There are few standardized and evaluated functional tests, examining functional muscular coordination which are also applicable in the non-laboratory setting. In ordinary clinical work, tests of functional muscular coordination should be easy to apply. The aim of this present study was to therefore standardize and examine the inter-rater reliability of three functional tests of muscular functional coordination of the lumbar spine in patients with low back pain. Methods Nineteen consecutive individuals, ten men and nine women were included. (Mean age 42 years, SD ± 12 yrs). Two independent examiners assessed three tests: "single limb stance", "sitting on a Bobath ball with one leg lifted" and "unilateral pelvic lift" on the same occasion. The standardization procedure took altered positions of the spine or pelvis and compensatory movements of the free extremities into account. The inter-rater reliability was analyzed by Cohen's kappa coefficient (κ) and by percentage agreement. Results The inter-rater reliability for the right and the left leg respectively was: for the single limb stance very good (κ: 0.88–1.0), for sitting on a Bobath ball good (κ: 0.79) and very good (κ: 0.88) and for the unilateral pelvic lift: good (κ: 0.61) and moderate (κ: 0.47). Conclusion The present study showed good to very good inter-rater reliability for two standardized tests, that is, the single-limb stance and sitting on a Bobath-ball with one leg lifted. Inter-rater reliability for the unilateral pelvic lift test was moderate to good. Validation of the tests in their ability to evaluate lumbar

  3. Inter-rater reliability of three standardized functional tests in patients with low back pain

    Directory of Open Access Journals (Sweden)

    Tidstrand Johan

    2009-06-01

    Full Text Available Abstract Background Of all patients with low back pain, 85% are diagnosed as "non-specific lumbar pain". Lumbar instability has been described as one specific diagnosis which several authors have described as delayed muscular responses, impaired postural control as well as impaired muscular coordination among these patients. This has mostly been measured and evaluated in a laboratory setting. There are few standardized and evaluated functional tests, examining functional muscular coordination which are also applicable in the non-laboratory setting. In ordinary clinical work, tests of functional muscular coordination should be easy to apply. The aim of this present study was to therefore standardize and examine the inter-rater reliability of three functional tests of muscular functional coordination of the lumbar spine in patients with low back pain. Methods Nineteen consecutive individuals, ten men and nine women were included. (Mean age 42 years, SD ± 12 yrs. Two independent examiners assessed three tests: "single limb stance", "sitting on a Bobath ball with one leg lifted" and "unilateral pelvic lift" on the same occasion. The standardization procedure took altered positions of the spine or pelvis and compensatory movements of the free extremities into account. The inter-rater reliability was analyzed by Cohen's kappa coefficient (κ and by percentage agreement. Results The inter-rater reliability for the right and the left leg respectively was: for the single limb stance very good (κ: 0.88–1.0, for sitting on a Bobath ball good (κ: 0.79 and very good (κ: 0.88 and for the unilateral pelvic lift: good (κ: 0.61 and moderate (κ: 0.47. Conclusion The present study showed good to very good inter-rater reliability for two standardized tests, that is, the single-limb stance and sitting on a Bobath-ball with one leg lifted. Inter-rater reliability for the unilateral pelvic lift test was moderate to good. Validation of the tests in their

  4. Test-retest reliability and responsiveness of the Barthel Index-based Supplementary Scales in patients with stroke.

    Science.gov (United States)

    Lee, Ya-Chen; Yu, Wan-Hui; Hsueh, I-Ping; Chen, Sheng-Shiung; Hsieh, Ching-Lin

    2017-10-01

    A lack of evidence on the test-retest reliability and responsiveness limits the utility of the BI-based Supplementary Scales (BI-SS) in both clinical and research settings. To examine the test-retest reliability and responsiveness of the BI-based Supplementary Scales (BI-SS) in patients with stroke. A repeated-assessments design (1 week apart) was used to examine the test-retest reliability of the BI-SS. For the responsiveness study, the participants were assessed with the BI-SS and BI (treated as an external criterion) at admission to and discharge from rehabilitation wards. Seven outpatient rehabilitation units and one inpatient rehabilitation unit. Outpatients with chronic stroke. Eighty-four outpatients with chronic stroke participated in the test-retest reliability study. Fifty-seven inpatients completed baseline and follow-up assessments in the responsiveness study. For the test-retest reliability study, the values of the intra-class correlation coefficient and the overall percentage of minimal detectable change for the Ability Scale and Self-perceived Difficulty Scale were 0.97, 12.8%, and 0.78, 35.8%, respectively. For the responsiveness study, the standardized effect size and standardized response mean (representing internal responsiveness) of the Ability Scale and Self-perceived Difficulty Scale were 1.17 and 1.56, and 0.78 and 0.89, respectively. Regarding external responsiveness, the change in score of the Ability Scale had significant and moderate association with that of the BI (r=0.61, Ptest-retest reliability and sufficient responsiveness for patients with stroke. However, the Self-perceived Difficulty Scale of the BI-SS has substantial random measurement error and insufficient external responsiveness, which may affect its utility in clinical settings. The findings of this study provide empirical evidence of psychometric properties of the BI-SS for assessing ability and self-perceived difficulty of ADL in patients with stroke.

  5. Relative and absolute test-retest reliabilities of pressure pain threshold in patients with knee osteoarthritis.

    Science.gov (United States)

    Srimurugan Pratheep, Neeraja; Madeleine, Pascal; Arendt-Nielsen, Lars

    2018-04-25

    Pressure pain threshold (PPT) and PPT maps are commonly used to quantify and visualize mechanical pain sensitivity. Although PPT's have frequently been reported from patients with knee osteoarthritis (KOA), the absolute and relative reliability of PPT assessments remain to be determined. Thus, the purpose of this study was to evaluate the test-retest relative and absolute reliability of PPT in KOA. For that purpose, intra- and interclass correlation coefficient (ICC) as well as the standard error of measurement (SEM) and the minimal detectable change (MDC) values within eight anatomical locations covering the most painful knee of KOA patients was measured. Twenty KOA patients participated in two sessions with a period of 2 weeks±3 days apart. PPT's were assessed over eight anatomical locations covering the knee and two remote locations over tibialis anterior and brachioradialis. The patients rated their maximum pain intensity during the past 24 h and prior to the recordings on a visual analog scale (VAS), and completed The Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) and PainDetect surveys. The ICC, SEM and MDC between the sessions were assessed. The ICC for the individual variability was expressed with coefficient of variance (CV). Bland-Altman plots were used to assess potential bias in the dataset. The ICC ranged from 0.85 to 0.96 for all the anatomical locations which is considered "almost perfect". CV was lowest in session 1 and ranged from 44.2 to 57.6%. SEM for comparison ranged between 34 and 71 kPa and MDC ranged between 93 and 197 kPa with a mean PPT ranged from 273.5 to 367.7 kPa in session 1 and 268.1-331.3 kPa in session 2. The analysis of Bland-Altman plot showed no systematic bias. PPT maps showed that the patients had lower thresholds in session 2, but no significant difference was observed for the comparison between the sessions for PPT or VAS. No correlations were seen between PainDetect and PPT and PainDetect and WOMAC

  6. Reliability of physical functioning tests in patients with low back pain: a systematic review.

    Science.gov (United States)

    Denteneer, Lenie; Van Daele, Ulrike; Truijen, Steven; De Hertogh, Willem; Meirte, Jill; Stassijns, Gaetane

    2018-01-01

    The aim of this study was to provide a comprehensive overview of physical functioning tests in patients with low back pain (LBP) and to investigate their reliability. A systematic computerized search was finalized in four different databases on June 24, 2017: PubMed, Web of Science, Embase, and MEDLINE. Preferred Reporting Items for Systematic Reviews and Meta-Analysis (PRISMA) guidelines were followed during all stages of this review. Clinical studies that investigate the reliability of physical functioning tests in patients with LBP were eligible. The methodological quality of the included studies was assessed with the use of the Consensus-based Standards for the selection of health Measurement Instruments (COSMIN) checklist. To come to final conclusions on the reliability of the identified clinical tests, the current review assessed three factors, namely, outcome assessment, methodological quality, and consistency of description. A total of 20 studies were found eligible and 38 clinical tests were identified. Good overall test-retest reliability was concluded for the extensor endurance test (intraclass correlation coefficient [ICC]=0.93-0.97), the flexor endurance test (ICC=0.90-0.97), the 5-minute walking test (ICC=0.89-0.99), the 50-ft walking test (ICC=0.76-0.96), the shuttle walk test (ICC=0.92-0.99), the sit-to-stand test (ICC=0.91-0.99), and the loaded forward reach test (ICC=0.74-0.98). For inter-rater reliability, only one test, namely, the Biering-Sörensen test (ICC=0.88-0.99), could be concluded to have an overall good inter-rater reliability. None of the identified clinical tests could be concluded to have a good intrarater reliability. Further investigation should focus on a better overall study methodology and the use of identical protocols for the description of clinical tests. The assessment of reliability is only a first step in the recommendation process for the use of clinical tests. In future research, the identified clinical tests in the

  7. High inter-rater reliability, agreement, and convergent validity of Constant score in patients with clavicle fractures

    DEFF Research Database (Denmark)

    Ban, Ilija; Troelsen, Anders; Kristensen, Morten Tange

    2016-01-01

    BACKGROUND: The Constant score (CS) has been the primary endpoint in most studies on clavicle fractures. However, the CS was not developed to assess patients with clavicle fractures. Our aim was to examine inter-rater reliability and agreement of the CS in patients with clavicle fractures...... standardized CS assessment at a mean of 6.8 weeks (SD, 1.0 weeks) after injury. Reliability and agreement of the CS were determined by 2 raters. The interclass correlation coefficient (ICC2,1), standard error of measurement, minimal detectable change, Cronbach α coefficient, and Pearson correlation coefficient...... were estimated. RESULTS: Inter-rater reliability of the total CS was excellent (interclass correlation coefficient, 0.94; 95% confidence interval, 0.88-0.97), with no systematic difference between the 2 raters (P = .75). The standard error of measurement (measurement error at the group level) was 4...

  8. The significance of motivation in periodontal treatment: validity and reliability of the motivation assessment scale among patients undergoing periodontal treatment.

    Science.gov (United States)

    Pac, A; Oruba, Z; Olszewska-Czyż, I; Chomyszyn-Gajewska, M

    2014-03-01

    The individual evaluation of patients' motivation should be introduced to the protocol of periodontal treatment, as it could impact positively on effective treatment planning and treatment outcomes. However, a standardised tool measuring the extent of periodontal patients' motivation has not yet been proposed in the literature. Thus, the objective of the present study was to determine the validity and reliability of the Zychlińscy motivation scale adjusted to the needs of periodontology. Cross sectional study. Department of Periodontology and Oral Medicine, Dental University Clinic, Jagiellonian University, Krakow, Poland. 199 adult periodontal patients, aged 20-78. 14-item questionnaire. The items were adopted from the original Zychlińscy motivation assessment scale. Validity and reliability of the proposed motivation assessment instrument. The assessed Cronbach's alpha of 0.79 indicates the scale is a reliable tool. Principal component analysis revealed a model with three factors, which explained half of the total variance. Those factors represented: the patient's attitude towards treatment and oral hygiene practice; previous experiences during treatment; and the influence of external conditions on the patient's attitude towards treatment. The proposed scale proved to be a reliable and accurate tool for the evaluation of periodontal patients' motivation.

  9. Reliability and Validity of the Turkish Adaptation of VITACORA-19 in Patients with Psoriatic Arthritis.

    Science.gov (United States)

    Tander, Berna; Ulus, Yasemin; Terzi, Yüksel; Zahiroğlu, Yeliz; Kesmen, Hakan; Farisoğullari, Bayram; Akyol, Yeşim; Bilgici, Ayhan; Kuru, Ömer

    2016-12-01

    This study aims to evaluate the reliability and validity of the Turkish language version of VITACORA-19 (psoriatic arthritis quality of life questionnaire) in patients with psoriatic arthritis. The Turkish version of VITACORA-19 questionnaire was obtained after a translation and back translation process. The study sample included 61 PsA patients (22 males, 39 females; mean age 46.5±12.2 years; range 19 to 71 years). To assess the test-retest reliability of the Turkish VITACORA-19, the questionnaire was reapplied 10 to 15 days after the first interview (interclass correlation coefficient). Cronbach's alpha (a) was used to evaluate the internal consistency. VITACORA-19 was compared with visual analog scale for physician and patient global assessments, the Health Assessment Questionnaire, and Nottingham Health Profile for construct validity. The internal structure of VITACORA-19 was examined by factor analysis. The individual item intraclass correlation coefficient ranged from 0.77 to 0.98 and Cronbach's alpha ranged from 0.77 to 0.98. The Cronbach's alpha value for whole scale was determined as 0.96. The Kaiser-Meyer-Olkin measure of sampling adequacy was 0.90, and Bartlett's test of sphericity had a p<0.001. Turkish VITACORA-19 total scores were correlated negatively with Health Assessment Questionnaire, visual analog scale for pain, and Nottingham Health Profile subgroups, and positively with physician and patient global assessments (p<0.01). Turkish version of VITACORA-19 questionnaire is a reliable and valid measure for health-related quality of life in Turkish patients with psoriatic arthritis.

  10. Reliability of gadolinium-enhanced magnetic resonance imaging findings and their correlation with clinical outcome in patients with sciatica.

    Science.gov (United States)

    el Barzouhi, Abdelilah; Vleggeert-Lankamp, Carmen L A M; Lycklama à Nijeholt, Geert J; Van der Kallen, Bas F; van den Hout, Wilbert B; Koes, Bart W; Peul, Wilco C

    2014-11-01

    Gadolinium-enhanced magnetic resonance imaging (Gd-MRI) is often performed in the evaluation of patients with persistent sciatica after lumbar disc surgery. However, correlation between enhancement and clinical findings is debated, and limited data are available regarding the reliability of enhancement findings. To evaluate the reliability of Gd-MRI findings and their correlation with clinical findings in patients with sciatica. Prospective observational evaluation of patients who were enrolled in a randomized trial with 1-year follow-up. Patients with 6- to 12-week sciatica, who participated in a multicentre randomized clinical trial comparing an early surgery strategy with prolonged conservative care with surgery if needed. In total 204 patients underwent Gd-MRI at baseline and after 1 year. Patients were assessed by means of the Roland Disability Questionnaire (RDQ) for sciatica, visual analog scale (VAS) for leg pain, and patient-reported perceived recovery at 1 year. Kappa coefficients were used to assess interobserver reliability. In total, 204 patients underwent Gd-MRI at baseline and after 1 year. Magnetic resonance imaging findings were correlated to the outcome measures using the Mann-Whitney U test for continuous data and Fisher exact tests for categorical data. Poor-to-moderate agreement was observed regarding Gd enhancement of the herniated disc and compressed nerve root (kappa0.95). Of the 59 patients with an enhancing herniated disc at 1 year, 86% reported recovery compared with 100% of the 12 patients with nonenhancing herniated discs (p=.34). Of the 12 patients with enhancement of the most affected nerve root at 1 year, 83% reported recovery compared with 85% of the 192 patients with no enhancement (p=.69). Patients with and without enhancing herniated discs or nerve roots at 1 year reported comparable outcomes on RDQ and VAS-leg pain. Reliability of Gd-MRI findings was poor-to-moderate and no correlation was observed between enhancement and

  11. UOP LDR 300 All Assignments New

    OpenAIRE

    ADMIN

    2018-01-01

    UOP LDR 300 All Assignments New Check this A+ tutorial guideline at http://www.ldr300assignment.com/ldr-300-uop/ldr-300-all-assignments-latest For more classes visit http://www.ldr300assignment.com LDR 300 Week 1 Assignment Leadership Assessment (2 Papers) LDR 300 Week 2 Assignment Leadership Theories Matrix (2 Set) LDR 300 Week 2 Assignment Formulating Leadership Part I (2 Papers) LDR 300 Week 3 Assignment Interaction and Influence Amo...

  12. Reliability of the Cardiac Patients Learning Needs Inventory (CPLNI) for use in Portugal.

    Science.gov (United States)

    Galdeano, Luzia E; Furuya, Rejane K; Rodrigues, Manuel A; Dantas, Rosana A S; Rossi, Lídia A

    2014-06-01

    To perform the semantic validation and to evaluate the reliability and the presence of ceiling and floor effects of the Cardiac Patients Learning Needs Inventory in Portuguese patients with coronary artery disease. Information should be selected based on what patients know and need to learn, which means that the teaching process should be based on each person's needs. The Cardiac Patients Learning Needs Inventory is aimed at identifying the cardiac patients' individual learning needs. Methodological research design. Two hundred patients hospitalised at the coronary intensive care unit or at the cardiothoracic surgery unit of a public hospital in Lisbon answered the adapted version of the Cardiac Patients Learning Needs Inventory. Internal consistency was estimated based on Cronbach's alpha. Scores above 0·50 were considered acceptable. Stability was measured through test-retest and calculated using student's t test. Significance was set at 0·05. Patients' mean age was 65 years (SD = 11·8), and most were men (152; 76%). Cronbach's alpha for the total scale was high in the first and second measurement (0·91), and for seven domains, it was acceptable in the first and second measurement (range from 0·50-0·89). No statistically significant difference was found between mean scores on the first and second measurement. Lower diversity was observed in the answers, most of which ranged between important and very important (ceiling-effect). The adapted version for use in Portugal maintained the conceptual, semantic and idiomatic equivalences of the original version and showed adequate reliability. RELEVANCE TO CLINICAL PRACTICES: Owing to the lack of validated instruments translated into Portuguese, to measure cardiac patients' learning needs, this study entails important clinical and theoretical implications. © 2012 Blackwell Publishing Ltd.

  13. Absolute and Relative Reliability of the Timed 'Up & Go' Test and '30second Chair-Stand' Test in Hospitalised Patients with Stroke

    DEFF Research Database (Denmark)

    Lyders Johansen, Katrine; Derby Stistrup, Rikke; Skibdal Schjøtt, Camilla

    2016-01-01

    OBJECTIVE: The timed 'Up & Go' test and '30second Chair-Stand' test are simple clinical outcome measures widely used to assess functional performance. The reliability of both tests in hospitalised stroke patients is unknown. The purpose was to investigate the relative and absolute reliability...... of both tests in patients admitted to an acute stroke unit. METHODS: Sixty-two patients (men, n = 41) attended two test sessions separated by a one hours rest. Intraclass correlation coefficients (ICC2,1) were calculated to assess relative reliability. Absolute reliability was expressed as Standard Error...... of Measurement (with 95% certainty-SEM95) and Smallest Real Difference (SRD) and as percentage of their respective means if heteroscedasticity was observed in Bland Altman plots (SEM95% and SRD%). RESULTS: ICC values for interrater reliability were 0.97 and 0.99 for the timed 'Up & Go' test and 0.88 and 0...

  14. Fair Package Assignment

    Science.gov (United States)

    Lahaie, Sébastien; Parkes, David C.

    We consider the problem of fair allocation in the package assignment model, where a set of indivisible items, held by single seller, must be efficiently allocated to agents with quasi-linear utilities. A fair assignment is one that is efficient and envy-free. We consider a model where bidders have superadditive valuations, meaning that items are pure complements. Our central result is that core outcomes are fair and even coalition-fair over this domain, while fair distributions may not even exist for general valuations. Of relevance to auction design, we also establish that the core is equivalent to the set of anonymous-price competitive equilibria, and that superadditive valuations are a maximal domain that guarantees the existence of anonymous-price competitive equilibrium. Our results are analogs of core equivalence results for linear prices in the standard assignment model, and for nonlinear, non-anonymous prices in the package assignment model with general valuations.

  15. Intra- and inter-rater reliability of the Knee Society Knee Score when used by two physiotherapists in patients post total knee arthroplasty

    Directory of Open Access Journals (Sweden)

    S. Gopal

    2010-01-01

    Full Text Available Background and Purpose: It has yet to be shown whether routine physiotherapy plays a role in the rehabilitation of patients post totalknee arthroplasty (Rajan et al 2004. Physiotherapists should be using validoutcome measures to provide evidence of the benefit of their intervention. The aim of this study was to establish the intra and inter-rater reliability of the Knee Society Knee Score, a scoring system developed by Insall et al(1989. The Knee Society Knee Score can be used to assess the integrity of theknee joint of patients undergoing total knee arthroplasty. Since the scoreinvolves clinical testing, the intra-rater reliability of the clinician should be established prior to using the scores as datain clinical research. W here multiple clinicians are involved, inter-rater reliability should also be established.Design: This was a correlation study.Subjects: A  sample of thirty patients post total knee arthroplasty attending the arthroplasty clinic at Johannesburg Hospital between six weeks and twelve months postoperatively.M ethod: Recruited patients were evaluated twice with a time interval of one hour between each assessment. Statistical A nalysis: The intra- and inter-rater reliability were estimated using Intraclass Correlation Coefficient (ICC. R esults: The intra-rater reliability showed excellent reliability (h= 0.95 for Examiner A  and good reliability (h= 0.71for Examiner B. The inter-rater reliability showed moderate reliability (h= 0.67 during test one and h= 0.66 during test two.Conclusion: The KSKS has good intra-rater reliability when tested within a period of one hour. The KSKS demonstrated moderate agreement for inter rater reliability.

  16. Position statement. The right to accept or reject an assignment. American Nurses Association.

    Science.gov (United States)

    1996-01-01

    The American Nurses Association (ANA) believes that nurses should reject assignment that puts patients or themselves in serious, immediate jeopardy. ANA supports the nurses obligation to reject an assignment in these situations even where there is not a specific legal protection for rejecting such an assignment. The professional obligations to the nurse to safeguard clients are grounded in the ethical norms of the profession, the Standards of Clinical Nursing Practice and state nurse practice acts.

  17. Validity and reliability of a new, short symptom rating scale in patients with persistent atrial fibrillation.

    Science.gov (United States)

    Härdén, Marie; Nyström, Britta; Kulich, Károly; Carlsson, Jonas; Bengtson, Ann; Edvardsson, Nils

    2009-07-15

    Symptoms related to atrial fibrillation and their impact on health-related quality of life (HRQoL) are often evaluated in clinical trials. However, there remains a need for a properly validated instrument. We aimed to develop and validate a short symptoms scale for patients with AF. One hundred and eleven patients with a variety of symptoms related to AF were scheduled for DC cardioversion. The mean age was 67.1 +/- 12.1 years, and 80% were men. The patients completed the new symptoms scale, the Toronto Symptoms Check List (SCL) and the generic Short Form 36 (SF-36) the day before the planned DC cardioversion. Compliance was excellent, with only 1 of 666 answers missing. One item, 'limitations in working capability', was deleted because of a low numerical response rate, as many of the patients were retired. The internal consistency reliability of the remaining six items was 0.81 (Cronbach's alpha). Patients scored highest in the items of 'dyspnoea on exertion', 'limitations in daily life due to AF' and 'fatigue due to AF', with scores of 4.5, 3.3 and 4.5, respectively. There was a good correlation to all relevant SF-36 domains and to the relevant questions of the SCL. The Rasch analyses showed that the items are unidimensional and that they are clearly separated and cover an adequate range. Test-retest reliability was performed in patients who failed DC and was adequate for three of six items, > 0.70. The psychometric characteristics of the new short symptoms scale were found to have satisfactory reliability and validity.

  18. The Danish Prostatic Symptom Score (DAN-PSS-1) questionnaire is reliable in stroke patients

    DEFF Research Database (Denmark)

    Tibaek, Sigrid; Jensen, Rigmor; Klarskov, Peter

    2006-01-01

    . The questionnaire consists of 12 questions related to lower urinary tract symptoms (LUTS). The participants were asked to state the frequency and severity of their symptoms (symptom score) and its impact on their daily life (bother score). Seventy-one stroke patients were included and 59 (83%) answered...... the questionnaire twice. The reliability test was done in two aspects: (a) detecting the frequency of each symptom and its bother factor, the scores were reduced to a two-category scale (=0, >0) and simple kappa statistics was used; (b) detecting the severity of each symptom and its bother factor, the total scale...... (kappa(w) = 0.48) to good (kappa(w) = 0.68). CONCLUSIONS: The DAN-PSS-1 questionnaire had acceptable test-retest reliability and may be suitable for measuring the frequency and severity of LUTS and its bother factor in stroke patients....

  19. A Reliable Method to Measure Lip Height Using Photogrammetry in Unilateral Cleft Lip Patients.

    Science.gov (United States)

    van der Zeeuw, Frederique; Murabit, Amera; Volcano, Johnny; Torensma, Bart; Patel, Brijesh; Hay, Norman; Thorburn, Guy; Morris, Paul; Sommerlad, Brian; Gnarra, Maria; van der Horst, Chantal; Kangesu, Loshan

    2015-09-01

    There is still no reliable tool to determine the outcome of the repaired unilateral cleft lip (UCL). The aim of this study was therefore to develop an accurate, reliable tool to measure vertical lip height from photographs. The authors measured the vertical height of the cutaneous and vermilion parts of the lip in 72 anterior-posterior view photographs of 17 patients with repairs to a UCL. Points on the lip's white roll and vermillion were marked on both the cleft and the noncleft sides on each image. Two new concepts were tested. First, photographs were standardized using the horizontal (medial to lateral) eye fissure width (EFW) for calibration. Second, the authors tested the interpupillary line (IPL) and the alar base line (ABL) for their reliability as horizontal lines of reference. Measurements were taken by 2 independent researchers, at 2 different time points each. Overall 2304 data points were obtained and analyzed. Results showed that the method was very effective in measuring the height of the lip on the cleft side with the noncleft side. When using the IPL, inter- and intra-rater reliability was 0.99 to 1.0, with the ABL it varied from 0.91 to 0.99 with one exception at 0.84. The IPL was easier to define because in some subjects the overhanging nasal tip obscured the alar base and gave more consistent measurements possibly because the reconstructed alar base was sometimes indistinct. However, measurements from the IPL can only give the percentage difference between the left and right sides of the lip, whereas those from the ABL can also give exact measurements. Patient examples were given that show how the measurements correlate with clinical assessment. The authors propose this method of photogrammetry with the innovative use of the IPL as a reliable horizontal plane and use of the EFW for calibration as a useful and reliable tool to assess the outcome of UCL repair.

  20. Pressure pain thresholds, clinical assessment, and differential diagnosis: reliability and validity in patients with myogenic pain.

    Science.gov (United States)

    Ohrbach, R; Gale, E N

    1989-11-01

    Four studies are presented testing the validity and reliability of pressure pain thresholds (PPTs) and of examination parameters believed to be important in the clinical assessment of sites commonly used for such measures in patient samples. Forty-five patients with a myogenous temporomandibular disorder were examined clinically prior to PPT measures. Criteria for history and examination included functional aspects of the pain, tissue quality of the pain site, and the type of pain elicited from palpation. Control sites within the same muscle and in the contralateral muscle were also examined. PPTs were measured as an index of tenderness using a strain gauge algometer at these sites. The data from the 5 male subjects were excluded from subsequent analyses due to the higher PPT in the males and to their unequal distribution among the various factorial conditions. The first study demonstrated strong validity in PPT measures between patients (using pain sites replicating the patients' pain) and matched controls (n = 11). The PPT was not significantly different between the primary pain site (referred pain and non-referred pain collapsed) and the no-pain control site in the same muscle (n = 16). The PPT was significantly lower at the pain site compared to the no-pain control site in the contralateral muscle (n = 13). The second study indicated adequate reliability in patient samples of the PPT measures. In the third study, the PPT was significantly lower at sites producing referred pain on palpation compared to sites producing localized pain on palpation. The PPT findings from the control sites were inconsistent on this factor. The fourth study presented preliminary evidence that palpable bands and nodular areas in muscle were most commonly associated with muscle regions that produce pain; such muscle findings were not specific, however, for regions that produce pain. Further, the intraexaminer reliability in reassessing these pain sites qualitatively was only fair

  1. The korean version of the body image scale-reliability and validity in a sample of breast cancer patients.

    Science.gov (United States)

    Khang, Dongwoo; Rim, Hyo-Deog; Woo, Jungmin

    2013-03-01

    The Body Image Scale (BIS) developed in collaboration with the European Organization for Research and Treatment of Cancer (EORTC) Quality of Life Study Group is a brief questionnaire for measuring body image concerns in patients with cancer. This study sought to assess the reliability and validity of the Korean version of the Body Image Scale (K-BIS). The participants consisted of 155 postoperative breast cancer patients (56 breast conserving surgery, 56 mastectomy, and 43 oncoplastic surgery). Subjects were evaluated using the K-BIS, the Body-Esteem Scale for Adolescents and Adults (BESAA), the Rosenberg Self-Esteem Scale (RSES), the Hospital Anxiety and Depression Scale (HADS), and the World Health Organization Quality of Life Scale Abbreviated Version (WHOQOL-BREF). Test-retest reliability and internal consistency were examined as a measure of reliability and validity was evaluated by convergent validity, discriminant validity and factor analysis. Cronbach's α value was 0.943. The total score of the K-BIS was negatively correlated with the BESAA (r=0.301, p59% variance. The K-BIS showed good reliability and validity for assessment of body image in Korean breast cancer patients.

  2. A human reliability based usability evaluation method for safety-critical software

    International Nuclear Information System (INIS)

    Boring, R. L.; Tran, T. Q.; Gertman, D. I.; Ragsdale, A.

    2006-01-01

    Boring and Gertman (2005) introduced a novel method that augments heuristic usability evaluation methods with that of the human reliability analysis method of SPAR-H. By assigning probabilistic modifiers to individual heuristics, it is possible to arrive at the usability error probability (UEP). Although this UEP is not a literal probability of error, it nonetheless provides a quantitative basis to heuristic evaluation. This method allows one to seamlessly prioritize and identify usability issues (i.e., a higher UEP requires more immediate fixes). However, the original version of this method required the usability evaluator to assign priority weights to the final UEP, thus allowing the priority of a usability issue to differ among usability evaluators. The purpose of this paper is to explore an alternative approach to standardize the priority weighting of the UEP in an effort to improve the method's reliability. (authors)

  3. Reliability and validity of the Athens Insomnia Scale in chronic pain patients

    Directory of Open Access Journals (Sweden)

    Enomoto K

    2018-04-01

    Full Text Available Kiyoka Enomoto,1–3 Tomonori Adachi,2–4 Keiko Yamada,5 Daisuke Inoue,2,6 Miho Nakanishi,7 Tomohiko Nishigami,2,8 Masahiko Shibata1,2 ¹Department of Pain Medicine, Osaka University Graduate School of Medicine, Suita, Japan; 2Center for Pain Management, Osaka University Hospital, Suita, Japan; 3Department of Anesthesiology, Interdisciplinary Pain Management Center, Shiga University of Medical Science Hospital, Otsu, Japan; 4Japan Society for the Promotion of Science (JSPS, Tokyo, Japan; 5Public Health, Department of Social Medicine, Osaka University Graduate School of Medicine, Suita, Japan; 6Department of Occupational Therapy, Osaka College of Rehabilitation, Osaka, Japan; 7Department of Anesthesiology, Shiga University of Medical Science, Otsu, Japan; 8Department of Nursing and Physical Therapy, Konan Woman’s University, Kobe, Japan Purpose: To confirm the psychometric properties of the Athens Insomnia Scale (AIS among Japanese chronic pain patients.Patients and methods: In total, 144 outpatients were asked to complete questionnaires comprising the AIS and other study measures. According to the original article, the AIS has 2 versions: the AIS-8 (full version and the AIS-5 (brief version. To validate the AIS-8 and AIS-5 among chronic pain patients, we confirmed: 1 factor structure by confirmatory factor analysis; 2 internal consistency by Cronbach’s a; 3 test–retest reliability using with interclass correlation coefficients; 4 known-group validity; 5 concurrent validity; and 6 cut-off values by receiver operating characteristic analysis. In addition, semi-structured interviews were conducted to assess the participants’ sleep disturbance. If the participants had any sleep complaints, including difficulty in initiating sleep, difficulty in maintaining sleep, and early morning awakening, they were defined as insomnia symptoms.Results: A 2-factor model of the AIS-8 and 1-factor model of the AIS-5 demonstrated good fit. The AIS had

  4. Plagiarism-Proofing Assignments

    Science.gov (United States)

    Johnson, Doug

    2004-01-01

    Mr. Johnson has discovered that the higher the level of student engagement and creativity, the lower the probability of plagiarism. For teachers who would like to see such desirable results, he describes the characteristics of assignments that are most likely to produce them. Two scenarios of types of assignments that avoid plagiarism are…

  5. Preliminary findings on the reliability and validity of the Cantonese Birmingham Cognitive Screen in patients with acute ischemic stroke.

    Science.gov (United States)

    Pan, Xiaoping; Chen, Haobo; Bickerton, Wai-Ling; Lau, Johnny King Lam; Kong, Anthony Pak Hin; Rotshtein, Pia; Guo, Aihua; Hu, Jianxi; Humphreys, Glyn W

    2015-01-01

    There are no currently effective cognitive assessment tools for patients who have suffered stroke in the People's Republic of China. The Birmingham Cognitive Screen (BCoS) has been shown to be a promising tool for revealing patients' poststroke cognitive deficits in specific domains, which facilitates more individually designed rehabilitation in the long run. Hence we examined the reliability and validity of a Cantonese version BCoS in patients with acute ischemic stroke, in Guangzhou. A total of 98 patients with acute ischemic stroke were assessed with the Cantonese version of the BCoS, and an additional 133 healthy individuals were recruited as controls. Apart from the BCoS, the patients also completed a number of external cognitive tests, including the Montreal Cognitive Assessment Test (MoCA), Mini Mental State Examination (MMSE), Albert's cancellation test, the Rey-Osterrieth Complex Figure Test, and six gesture matching tasks. Cutoff scores for failing each subtest, ie, deficits, were computed based on the performance of the controls. The validity and reliability of the Cantonese BCoS were examined, as well as interrater and test-retest reliability. We also compared the proportions of cases being classified as deficits in controlled attention, memory, character writing, and praxis, between patients with and without spoken language impairment. Analyses showed high test-retest reliability and agreement across independent raters on the qualitative aspects of measurement. Significant correlations were observed between the subtests of the Cantonese BCoS and the other external cognitive tests, providing evidence for convergent validity of the Cantonese BCoS. The screen was also able to generate measures of cognitive functions that were relatively uncontaminated by the presence of aphasia. This study suggests good reliability and validity of the Cantonese version of the BCoS. The Cantonese BCoS is a very promising tool for the detection of cognitive problems in

  6. The reliability and validity of Chinese version of SF36 v2 in aging patients with chronic heart failure.

    Science.gov (United States)

    Dong, Aishu; Chen, Sisi; Zhu, Lianlian; Shi, Lingmin; Cai, Yueli; Zeng, Jingni; Guo, Wenjian

    2017-08-01

    Chronic heart failure (CHF), a major public health problem worldwide, seriously limits health-related quality of life (HRQOL). How to evaluate HRQOL in older patients with CHF remains a problem. To evaluate the reliability and validity of the Chinese version of the Medical Outcomes Study Short Form version 2 (SF-36v2) in CHF patients. From September 2012 to June 2014, we assessed QOL using the SF-36v2 in 171 aging participants with CHF in four cardiology departments. Convergent and discriminant validity, factorial validity, sensitivity among different NYHA classes and between different age groups, and reliability were determined using standard measurement methods. A total of 150 participants completed a structured questionnaire including general information and the Chinese SF-36v2; 132 questionnaires were considered valid, while 21 patients refused to take part. 25 of the 50 participants invited to complete the 2-week test-retest questionnaires returned completed questionnaires. The internal consistency reliability (Cronbach's α) of the total SF-36v2 was 0.92 (range 0.74-0.93). All hypothesized item-subscale correlations showed satisfactory convergent and discriminant validity. Sensitivity was measured in different NYHA classes and age groups. Comparison of different NYHA classes showed statistical significance, but there was no significant difference between age groups. We confirmed the SF-36v2 as a valid instrument for evaluating HRQOL Chinese CHF patients. Both reliability and validity were strongly satisfactory, but there was divergence in understanding subscales such as "social functioning" because of differing cultural background. The reliability, validity, and sensitivity of SF-36v2 in aging patients with CHF were acceptable.

  7. System reliability, performance and trust in adaptable automation.

    Science.gov (United States)

    Chavaillaz, Alain; Wastell, David; Sauer, Jürgen

    2016-01-01

    The present study examined the effects of reduced system reliability on operator performance and automation management in an adaptable automation environment. 39 operators were randomly assigned to one of three experimental groups: low (60%), medium (80%), and high (100%) reliability of automation support. The support system provided five incremental levels of automation which operators could freely select according to their needs. After 3 h of training on a simulated process control task (AutoCAMS) in which the automation worked infallibly, operator performance and automation management were measured during a 2.5-h testing session. Trust and workload were also assessed through questionnaires. Results showed that although reduced system reliability resulted in lower levels of trust towards automation, there were no corresponding differences in the operators' reliance on automation. While operators showed overall a noteworthy ability to cope with automation failure, there were, however, decrements in diagnostic speed and prospective memory with lower reliability. Copyright © 2015. Published by Elsevier Ltd.

  8. Validity and reliability of a new, short symptom rating scale in patients with persistent atrial fibrillation

    Directory of Open Access Journals (Sweden)

    Bengtson Ann

    2009-07-01

    Full Text Available Abstract Background Symptoms related to atrial fibrillation and their impact on health-related quality of life (HRQoL are often evaluated in clinical trials. However, there remains a need for a properly validated instrument. We aimed to develop and validate a short symptoms scale for patients with AF. Methods One hundred and eleven patients with a variety of symptoms related to AF were scheduled for DC cardioversion. The mean age was 67.1 ± 12.1 years, and 80% were men. The patients completed the new symptoms scale, the Toronto Symptoms Check List (SCL and the generic Short Form 36 (SF-36 the day before the planned DC cardioversion. Compliance was excellent, with only 1 of 666 answers missing. Results One item, 'limitations in working capability', was deleted because of a low numerical response rate, as many of the patients were retired. The internal consistency reliability of the remaining six items was 0.81 (Cronbach's α. Patients scored highest in the items of 'dyspnoea on exertion', 'limitations in daily life due to AF' and 'fatigue due to AF', with scores of 4.5, 3.3 and 4.5, respectively. There was a good correlation to all relevant SF-36 domains and to the relevant questions of the SCL. The Rasch analyses showed that the items are unidimensional and that they are clearly separated and cover an adequate range. Test-retest reliability was performed in patients who failed DC and was adequate for three of six items, >0.70. Conclusion The psychometric characteristics of the new short symptoms scale were found to have satisfactory reliability and validity.

  9. The reliability of lung crackle characteristics in cystic fibrosis and bronchiectasis patients in a clinical setting

    International Nuclear Information System (INIS)

    Marques, Alda; Bruton, Anne; Barney, Anna

    2009-01-01

    Lung sounds provide useful information for assessing and monitoring respiratory patients, but standard auscultation is subjective. Computer aided lung sound analysis (CALSA) enables the quantification and characterisation of added lung sounds (e.g. crackles). At present, little is known about the reliability of these sound characteristics. Therefore, the aim of this study was to explore the reliability of crackle initial deflection width (IDW) and two-cycle deflection (2CD) in a clinical population. Fifty-four subjects (37 bronchiectasis, 17 cystic fibrosis) were recruited from out-patient clinics. Three repeated lung sound recordings were taken at seven anatomical sites with a digital stethoscope connected to a laptop computer. The intra-subject reliability of crackle IDW and 2CD was found to be 'good' to 'excellent', estimated by the analysis of variance, intraclass correlation coefficient (IDW 0.76;0.85, 2CD 0.83;0.94), Bland and Altman 95% limits of agreement (IDW −0.50;0.47 ms, 2CD −2.12;1.87 ms) and smallest real difference (IDW 0.30;0.66 ms, 2CD 1.57;2.42 ms). Crackle 2CD was found to be more reliable than IDW. It is concluded that crackle IDW and 2CD characterized by CALSA have good test–retest reliability. This technique requires further evaluation since CALSA has potential to diagnose or monitor respiratory conditions, and provide an objective physiological measure for respiratory interventions

  10. Assessment of disabilities in stroke patients with apraxia : Internal consistency and inter-observer reliability

    NARCIS (Netherlands)

    van Heugten, CM; Dekker, J; Deelman, BG; Stehmann-Saris, JC; Kinebanian, A

    1999-01-01

    In this paper the internal consistency and inter-observer reliability of the assessment of disabilities in stroke patients with apraxia is presented. Disabilities were assessed by means of observation of activities of daily living (ADL). The study was conducted at occupational therapy departments in

  11. Assessment of disabilities in stroke patients with apraxia: internal consistency and inter-observer reliability.

    NARCIS (Netherlands)

    Heugten, C.M. van; Dekker, J.; Deelman, B.G.; Stehmann-Saris, J.C.; Kinebanian, A.

    1999-01-01

    In this paper the internal consistency and inter-observer reliability of the assessment of disabilities in stroke patients with apraxia is presented. Disabilities were assessed by means of observation of activities of daily living (ADL). The study was conducted at occupational therapy departments in

  12. Outcome of lithium prophylaxis: a prospective follow-up of affective disorder patients assigned to high and low serum lithium levels

    DEFF Research Database (Denmark)

    Vestergaard, Per; Licht, Rasmus Wentzer; Brodersen, Anders Torp

    1998-01-01

    The purpose of the study was to examine the outcome of long-term lithium treatment in consecutively admitted affective disorder patients assigned to high and low serum lithium levels. A total of 91 patients were diagnosed according to DSM-III criteria and randomly allocated to two open treatment...... groups in which prophylactic lithium was administered in high (serum lithium 0.8-1.0 mmol L-1) and low (serum lithium 0.5-0.8 mmol L-1) doses, respectively. The patients were followed for 2 years or until discontinuation of lithium treatment or readmission to hospital for recurrence of affective illness....... The main outcome of the treatment groups was compared with Kaplan-Meier survival curves and by Cox regression analysis. A total of 31 patients (34%) completed 24 months of prophylactic lithium treatment without recurrence and readmission to hospital. In total, 18 patients (20%) suffered a recurrence...

  13. Reliability, validity and sensitivity to change of neurogenic bowel dysfunction score in patients with spinal cord injury

    DEFF Research Database (Denmark)

    Erdem, D.; Hava, D.; Keskinoglu, P.

    2017-01-01

    cord injury (SCI). The reliability of NBD score was assessed by test-retest reliability and internal consistency. Cronbach's alpha coefficient was calculated to determine internal consistency. The construct validity was evaluated by exploring correlations between the NBD score and SF-36 scales, patient...... assessment of impact of NBD on quality of life (QoL) and the physician global assessment (PGA). The Global Rating of Change (GRC) scale was used to assess the change of NBD to investigate the sensitivity of the score to change. Results: Cronbach's alpha coefficient was 0.547. In test-retest reliability...

  14. Development of virtual patient models for permanent implant brachytherapy Monte Carlo dose calculations: interdependence of CT image artifact mitigation and tissue assignment.

    Science.gov (United States)

    Miksys, N; Xu, C; Beaulieu, L; Thomson, R M

    2015-08-07

    This work investigates and compares CT image metallic artifact reduction (MAR) methods and tissue assignment schemes (TAS) for the development of virtual patient models for permanent implant brachytherapy Monte Carlo (MC) dose calculations. Four MAR techniques are investigated to mitigate seed artifacts from post-implant CT images of a homogeneous phantom and eight prostate patients: a raw sinogram approach using the original CT scanner data and three methods (simple threshold replacement (STR), 3D median filter, and virtual sinogram) requiring only the reconstructed CT image. Virtual patient models are developed using six TAS ranging from the AAPM-ESTRO-ABG TG-186 basic approach of assigning uniform density tissues (resulting in a model not dependent on MAR) to more complex models assigning prostate, calcification, and mixtures of prostate and calcification using CT-derived densities. The EGSnrc user-code BrachyDose is employed to calculate dose distributions. All four MAR methods eliminate bright seed spot artifacts, and the image-based methods provide comparable mitigation of artifacts compared with the raw sinogram approach. However, each MAR technique has limitations: STR is unable to mitigate low CT number artifacts, the median filter blurs the image which challenges the preservation of tissue heterogeneities, and both sinogram approaches introduce new streaks. Large local dose differences are generally due to differences in voxel tissue-type rather than mass density. The largest differences in target dose metrics (D90, V100, V150), over 50% lower compared to the other models, are when uncorrected CT images are used with TAS that consider calcifications. Metrics found using models which include calcifications are generally a few percent lower than prostate-only models. Generally, metrics from any MAR method and any TAS which considers calcifications agree within 6%. Overall, the studied MAR methods and TAS show promise for further retrospective MC dose

  15. Reliability of injury grading systems for patients with blunt splenic trauma.

    Science.gov (United States)

    Olthof, D C; van der Vlies, C H; Scheerder, M J; de Haan, R J; Beenen, L F M; Goslings, J C; van Delden, O M

    2014-01-01

    The most widely used grading system for blunt splenic injury is the American Association for the Surgery of Trauma (AAST) organ injury scale. In 2007 a new grading system was developed. This 'Baltimore CT grading system' is superior to the AAST classification system in predicting the need for angiography and embolization or surgery. The objective of this study was to assess inter- and intraobserver reliability between radiologists in classifying splenic injury according to both grading systems. CT scans of 83 patients with blunt splenic injury admitted between 1998 and 2008 to an academic Level 1 trauma centre were retrospectively reviewed. Inter and intrarater reliability were expressed in Cohen's or weighted Kappa values. Overall weighted interobserver Kappa coefficients for the AAST and 'Baltimore CT grading system' were respectively substantial (kappa=0.80) and almost perfect (kappa=0.85). Average weighted intraobserver Kappa's values were in the 'almost perfect' range (AAST: kappa=0.91, 'Baltimore CT grading system': kappa=0.81). The present study shows that overall the inter- and intraobserver reliability for grading splenic injury according to the AAST grading system and 'Baltimore CT grading system' are equally high. Because of the integration of vascular injury, the 'Baltimore CT grading system' supports clinical decision making. We therefore recommend use of this system in the classification of splenic injury. Copyright © 2012 Elsevier Ltd. All rights reserved.

  16. Reliability of the Danish Abbey Pain Scale in severely demented and non-communicative older patients.

    Science.gov (United States)

    Gregersen, Merete; Melin, Anne Sophie; Nygaard, Ida Sofie; Nielsen, Christina H; Beedholm-Ebsen, Mathilde

    2016-10-02

    To validate a Danish version of the observational Abbey Pain Scale (APS) in a geriatric ward. The study population consisted of 50 old patients (70+ years), consecutively admitted to the geriatric wards of Aarhus University Hospital, Denmark, and fulfilling one of the following inclusion criteria: Mini Mental State Examination (MMSE) reliability was measured by two independent ratings of the same patient at the same time and assessed by Intraclass Correlation Coefficient (ICC). Internal consistency between the subscales was analysed by Cronbach's Alpha. Responsiveness was tested if the first APS score was positive for pain. 'Before' and 'after' sum scores were compared by paired t-test. We found poor agreement between APS and VRS (k=0.42). The inter-rater reliability was good (ICC=0.84). Cronbach's Alpha was 0.52 (fair agreement). In 66% of the patients, pain was observed and re-tested when an expected effect of analgesics had occurred. Of these, 88% reached a reduction on the APS sum-score (p<0.001). Our assessment of the Danish version of APS shows that this pain assessment scale should be considered as qualified and usable in severely demented and non-communicative older patients admitted to a geriatric ward.

  17. High intertester reliability of the cumulated ambulation score for the evaluation of basic mobility in patients with hip fracture

    DEFF Research Database (Denmark)

    Kristensen, Morten Tange; Andersen, Lene; Bech-Jensen, Rie

    2009-01-01

    OBJECTIVE: To examine the intertester reliability of the three activities of the Cumulated Ambulation Score (CAS) and the total CAS, and to define limits for the smallest change in basic mobility that indicates a real change in patients with hip fracture. DESIGN: An intertester reliability study....... SETTING: An acute 20-bed orthopaedic hip fracture unit. SUBJECTS: Fifty consecutive patients with a median age of 83 (25-75% quartile, 68-86) years. INTERVENTIONS: The CAS, which describes the patient's independency in three activities - (1) getting in and out of bed, (2) sit to stand from a chair, and (3...

  18. Safety and reliability of the insertable Reveal XT recorder in patients undergoing 3 Tesla brain magnetic resonance imaging.

    Science.gov (United States)

    Haeusler, Karl Georg; Koch, Lydia; Ueberreiter, Juliane; Coban, Nalan; Safak, Erdal; Kunze, Claudia; Villringer, Kersten; Endres, Matthias; Schultheiss, Heinz-Peter; Fiebach, Jochen B; Schirdewan, Alexander

    2011-03-01

    Up to now there is little evidence about the safety and reliability of insertable cardiac monitors (ICMs) in patients undergoing magnetic resonance imaging (MRI). The purpose of this prospective single-center study (MACPAF; clinicaltrials.govNCT01061931), which we are currently performing, was to evaluate these issues for the ICM Reveal XT at a 3 Tesla MRI scanner in patients undergoing serial brain MRI. We present an interim analysis including 62 brain MRI examinations in 24 patients with paroxysmal atrial fibrillation bearing the Reveal XT. All patients were interviewed for potential ICM-associated clinical symptoms during and after MRI examination. According to the study protocol, data from the Reveal XT were transmitted before and after the MRI examination. All patients were clinically asymptomatic during the MRI procedure. Moreover, the reliability (ability to detect signals, battery status) of the Reveal XT was unaffected, except for one MRI-induced artifact that was recorded by the ICM, mimicking a narrow complex tachycardia, as similarly recorded in a further study patient bearing the forerunner ICM Reveal DX. No loss of ICM data was observed after the MRI examination. The 3 Tesla brain MRI scanning is safe for patients bearing the ICM Reveal XT and does not alloy reliability of the Reveal XT itself. MRI-induced artifacts occur rarely but have to be taken into account. Copyright © 2011 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  19. A fuzzy-based particle swarm optimisation approach for task assignment in home healthcare

    Directory of Open Access Journals (Sweden)

    Mutingi, Michael

    2014-11-01

    Full Text Available Home healthcare (HHC organisations provide coordinated healthcare services to patients at their homes. Motivated by the ever-increasing need for home-based care, the assignment of tasks to available healthcare staff is a common and complex problem in homecare organisations. Designing high quality task schedules is critical for improving worker morale, job satisfaction, service efficiency, service quality, and competitiveness over the long term. The desire is to provide high quality task assignment schedules that satisfy the patient, the care worker, and the management. This translates to maximising schedule fairness in terms of workload assignments, avoiding task time window violation, and meeting management goals as much as possible. However, in practice, these desires are often subjective as they involve imprecise human perceptions. This paper develops a fuzzy multi-criteria particle swarm optimisation (FPSO approach for task assignment in a home healthcare setting in a fuzzy environment. The proposed approach uses a fuzzy evaluation method from a multi-criteria point of view. Results from illustrative computational experiments show that the approach is promising.

  20. Reliability and validity of the Physical Activity Scale for the Elderly (PASE in patients with hip osteoarthritis

    Directory of Open Access Journals (Sweden)

    Svege Ida

    2012-02-01

    Full Text Available Abstract Background Physical activity (PA is beneficial in reducing pain and improving function in lower limb osteoarthritis (OA, and is recommended as a first line treatment. Self-administered questionnaires are used to assess PA, but knowledge about reliability and validity of these PA questionnaires are limited, in particular for patients with OA. The purpose of this study was to evaluate the reliability and validity of the Physical Activity Scale for the Elderly (PASE in patients with hip OA. Methods Forty patients with hip OA (20 men and 20 women, mean age 61.3 ± 10 years were included. For test-retest reliability PASE was administered twice with a mean time between tests of 9 ± 4 days. Intraclass correlation coefficient (ICC, standard error of measurement (SEM and minimal detectable change (MDC were calculated for the total score and for the particular items assessing different PA intensity levels. In addition a Bland-Altman analysis for the total PASE score was performed. Construct validity was evaluated by comparing the PASE results with the Actigraph GT1M accelerometer and the International Physical Activity Questionnaire (IPAQ, using the Spearman rank correlation coefficient. Results ICC for the total PASE score was 0.78, with relatively large error of measurement; SEM = 31 and MDC = 87. ICC for the intensity items was 0.20 for moderate PA intensity, 0.46 for light PA intensity and to 0.68 for vigorous PA intensity. The Spearman rank correlation coefficient between the Actigraph GT1M total counts per minute and the total PASE score was 0.30 (p = 0.089, and ranging from 0.20-0.38 for the different PA intensity categories. The Spearman rank correlation between IPAQ and PASE was 0.61 (p = 0.001 for the total scores. Conclusions In patients with hip OA the test-retest reliability of the total PASE score was moderate, with acceptable ICC, but with large measurement errors. The construct validity of the PASE was poor when compared to the

  1. Development of a Tablet-based symbol digit modalities test for reliably assessing information processing speed in patients with stroke.

    Science.gov (United States)

    Tung, Li-Chen; Yu, Wan-Hui; Lin, Gong-Hong; Yu, Tzu-Ying; Wu, Chien-Te; Tsai, Chia-Yin; Chou, Willy; Chen, Mei-Hsiang; Hsieh, Ching-Lin

    2016-09-01

    To develop a Tablet-based Symbol Digit Modalities Test (T-SDMT) and to examine the test-retest reliability and concurrent validity of the T-SDMT in patients with stroke. The study had two phases. In the first phase, six experts, nine college students and five outpatients participated in the development and testing of the T-SDMT. In the second phase, 52 outpatients were evaluated twice (2 weeks apart) with the T-SDMT and SDMT to examine the test-retest reliability and concurrent validity of the T-SDMT. The T-SDMT was developed via expert input and college student/patient feedback. Regarding test-retest reliability, the practise effects of the T-SDMT and SDMT were both trivial (d=0.12) but significant (p≦0.015). The improvement in the T-SDMT (4.7%) was smaller than that in the SDMT (5.6%). The minimal detectable changes (MDC%) of the T-SDMT and SDMT were 6.7 (22.8%) and 10.3 (32.8%), respectively. The T-SDMT and SDMT were highly correlated with each other at the two time points (Pearson's r=0.90-0.91). The T-SDMT demonstrated good concurrent validity with the SDMT. Because the T-SDMT had a smaller practise effect and less random measurement error (superior test-retest reliability), it is recommended over the SDMT for assessing information processing speed in patients with stroke. Implications for Rehabilitation The Symbol Digit Modalities Test (SDMT), a common measure of information processing speed, showed a substantial practise effect and considerable random measurement error in patients with stroke. The Tablet-based SDMT (T-SDMT) has been developed to reduce the practise effect and random measurement error of the SDMT in patients with stroke. The T-SDMT had smaller practise effect and random measurement error than the SDMT, which can provide more reliable assessments of information processing speed.

  2. Test-retest reliability of handgrip strength measurement using a hydraulic hand dynamometer in patients with cervical radiculopathy.

    Science.gov (United States)

    Savva, Christos; Giakas, Giannis; Efstathiou, Michalis; Karagiannis, Christos

    2014-01-01

    The purpose of this study was to evaluate the test-retest reliability of handgrip strength measurement using a hydraulic hand dynamometer in patients with cervical radiculopathy (CR). A convenience sample of 19 participants (14 men and 5 women; mean ± SD age, 50.5 ± 12 years) with CR was measured using a Jamar hydraulic hand dynamometer by the same rater on 2 different testing sessions with an interval of 7 days between sessions. Data collection procedures followed standardized grip strength testing guidelines established by the American Society of Hand Therapists. During the repeated measures, patients were advised to rest their upper limb in the standardized arm position and encouraged to exert 3 maximum gripping efforts. The mean value of the 3 efforts (measured in kilogram force [Kgf]) was used for data analysis. The intraclass correlation coefficient, SEM, and the Bland-Altman plot were used to estimate test-retest reliability and measurement precision. Grip strength measurement in CR demonstrated an intraclass correlation coefficient of 0.976, suggesting excellent test-retest reliability. The small SEM in both testing sessions (SEM1, 2.41 Kgf; SEM2, 2.51 Kgf) as well as the narrow width of the 95% limits of agreements (95% limits of agreement, -4.9 to 4.4 Kgf) in the Bland-Altman plot reflected precise measurements of grip strength in both occasions. Excellent test-retest reliability for grip strength measurement was measured in patients with CR, demonstrating that a hydraulic hand dynamometer could be used as an outcome measure for these patients. Copyright © 2014 National University of Health Sciences. Published by Mosby, Inc. All rights reserved.

  3. Validity and reliability of the patient assessment of constipation quality of life questionnaire for the Turkish population.

    Science.gov (United States)

    Bengi, Göksel; Yalçın, Mustafa; Akpınar, Hale; Keskinoğlu, Pembe; Ellidokuz, Hülya

    2015-07-01

    There are few specific evaluation forms for evaluating the quality of life among patients with chronic constipation. Our study aimed to determine the validity and reliability of the translated Patient Assessment of Constipation Quality of Life (PAC-QOL) questionnaire for the Turkish population because evidence of its reliability and validity is required to justify its use in other studies and clinical practice. This study included 154 patients with constipation who were treated at the Department of Gastroenterology, Dokuz Eylül University Hospital between January and June 2012. The translated PAC-QOL questionnaire was completed by patients at the clinic and also at a 2-week follow-up to test its reliability. Cronbach's alpha coefficient (internal consistency) was 0.91 (good) for the translated PAC-QOL questionnaire. Time validity was evaluated using the intraclass correlation coefficient (ICC) method, and the ICC value for all questions was confirmed as 0.68 at the 2-week follow-up. The validity of the tool in the study group was evaluated using factor analysis, and the results were highly significant (Kaiser-Meyer-Olkin value: 0.857; Bartlett's test: p=0.001). Questions were categorized according to six factors based on the factor analysis, and these factors explained 65.1% of the total variation. For hypothesis verification of the tool, the correlation coefficient for PAC-QOL and PAC Symptoms (PAC-SYM) was r=0.577 (p<0.001), whereas the correlation coefficient for PAC-QOL and constipation severity score was r=0.457 (p<0.001). The PAC-QOL questionnaire was reliable, although not valid because of the limited sample group.

  4. Patient Assessment of Constipation Quality of Life Questionnaire: Translation, Cultural Adaptation, Reliability, and Validity of the Persian Version.

    Science.gov (United States)

    Nikjooy, Afsaneh; Jafari, Hassan; Saba, Maryam A; Ebrahimi, Naghmeh; Mirzaei, Rezvan

    2018-05-01

    The Patient Assessment of Constipation Quality of Life (PAC-QOL) questionnaire is the most validated and the most specific tool for measuring the quality of life of patients with constipation. Over 120 million people live in countries whose official language is Persian. There is no reported Persian version of the PAC-QOL questionnaire yet. The aim of this study was to translate and culturally adapt the PAC-QOL questionnaire and to assess its reliability and validity among Persian patients with chronic constipation. Following the translation and cultural adaptation of the PAC-QOL questionnaire to Persian, 100 patients (mean±SD age=40.51±13.67) with constipation were recruited for validity measurement and 20 patients were re-examined for reliability. Content validity was assessed based on the opinions of an expert committee and the floor/ceiling effect. Construct validity was evaluated according to the hypothesis test. The SF-36 questionnaire was used for concurrent criterion validity, intra-class correlation coefficient for reliability, and Cronbach's alpha for internal consistency. The content validity of the PAC-QOL questionnaire was proven, and there was no floor/ceiling effect. Construct validity also was confirmed based on the hypothesis test. The overall Cronbach's alpha of the PAC-QOL questionnaire was 0.92 (range=0.72-0.92), and the overall intra-class correlation coefficient of the questionnaire was 0.88 (range=0.69-0.87). The correlation between the SF-36 and PAC-QOL questionnaires was moderate. The Persian version of the PAC-QOL questionnaire demonstrated good validity and reliability properties in chronic constipation. Accordingly, Persian researchers and clinicians can benefit from this questionnaire in further research and assessment of treatment outcomes.

  5. The (digital) natives are restless: designing and implementing an interactive digital media assignment.

    Science.gov (United States)

    Voge, Catherine; Hirvela, Kari; Jarzemsky, Paula

    2012-01-01

    To create an opportunity for students to connect with the Quality and Safety Education for Nurses competencies and demonstrate learning via knowledge transference, the authors piloted a digital media assignment. Students worked in small groups to create an unfolding patient care scenario with embedded decision points, using presentation software. The authors discuss the assignment and its outcomes.

  6. Dynamic Sequence Assignment.

    Science.gov (United States)

    1983-12-01

    D-136 548 DYNAMIIC SEQUENCE ASSIGNMENT(U) ADVANCED INFORMATION AND 1/2 DECISION SYSTEMS MOUNTAIN YIELW CA C A 0 REILLY ET AL. UNCLSSIIED DEC 83 AI/DS...I ADVANCED INFORMATION & DECISION SYSTEMS Mountain View. CA 94040 84 u ,53 V,..’. Unclassified _____ SCURITY CLASSIFICATION OF THIS PAGE REPORT...reviews some important heuristic algorithms developed for fas- ter solution of the sequence assignment problem. 3.1. DINAMIC MOGRAMUNIG FORMULATION FOR

  7. "Graded Cycling Test with Talk Test" Is a Reliable Test to Monitor Cardiovascular Fitness in Patients with Minor Stroke

    DEFF Research Database (Denmark)

    Steen Krawcyk, Rikke; Vinther, Anders; Caesar Petersen, Nicolas

    2017-01-01

    variability may challenge currently used cardiovascular monitoring. The Graded Cycling Test with Talk Test is a submaximal exercise test independent of heart rate variability, shown reliable for patients with cardiac disease. METHODS: Patients diagnosed with lacunar stroke according to TOAST (Trial of Org...... a minor measurement error: 12.9 W for groups of patients (standard error of measurement, SEM95) and 18.3 W for individual patients (smallest real difference). CONCLUSION: The "Graded Cycling Test with Talk Test" is feasible and reliable for monitoring exercise effects in patients with lacunar stroke...... 10172 in Acute Stroke Treatment) criteria performed an incremental exercise test on a stationary bicycle with a 15 W (watt) increase in workload every minute. Toward the end of each incremental step, the patients recited a standardized text passage and subsequently were asked: "Are you still able...

  8. The MOBID-2 pain scale: reliability and responsiveness to pain in patients with dementia.

    Science.gov (United States)

    Husebo, B S; Ostelo, R; Strand, L I

    2014-11-01

    Mobilization-Observation-Behavior-Intensity-Dementia-2 (MOBID-2) pain scale is a staff-administered pain tool for patients with dementia. This study explores MOBID-2's test-retest reliability, measurement error and responsiveness to change. Analyses are based upon data from a cluster randomized trial including 352 patients with advanced dementia from 18 Norwegian nursing homes. Test-retest reliability between baseline and week 2 (n = 163), and weeks 2 and 4 (n = 159) was examined in patients not expected to change (controls), using intraclass correlation coefficient (ICC2.1 ), standard error of measurement (SEM) and smallest detectable change (SDC). Responsiveness was examined by testing six priori-formulated hypotheses about the association between change scores on MOBID-2 and other outcome measures. ICCs of the total MOBID-2 scores were 0.81 (0-2 weeks) and 0.85 (2-4 weeks). SEM and SDC were 1.9 and 3.1 (0-2 weeks) and 1.4 and 2.3 (2-4 weeks), respectively. Five out of six hypotheses were confirmed: MOBID-2 discriminated (p Mini-Mental State Examination, Functional Assessment Staging and Activity of Daily Living. Expected associations between change scores of MOBID-2 and Neuropsychiatric Inventory - Nursing Home version were not confirmed. The SEM and SDC in connection with the MOBID-2 pain scale indicate that the instrument is responsive to a decrease in pain after a SPTP. Satisfactory test-retest reliability across test periods was demonstrated. Change scores ≥ 3 on total and subscales are clinically relevant and are beyond measurement error. © 2014 The Authors. European Journal of Pain published by John Wiley & Sons Ltd on behalf of European Pain Federation - EFIC®.

  9. Imaging the femoral sulcus with ultrasound, CT, and MRI: reliability and generalizability in patients with patellar instability

    Energy Technology Data Exchange (ETDEWEB)

    Toms, Andoni P.; Cahir, John [Norfolk and Norwich University Hospital, Departments of Radiology, Norwich, Norfolk (United Kingdom); Swift, Louise [University of East Anglia, School of Medicine, Health Policy and Practice, Norwich, Norfolk (United Kingdom); Donell, Simon T. [Norfolk and Norwich University Hospital, Institute of Orthopedics, Norwich, Norfolk (United Kingdom)

    2009-04-15

    Recent advances in surgical intervention for patellar instability have led to a need for long-term radiological monitoring. The aim of this study is to determine whether or not magnetic resonance imaging (MRI) or ultrasound (US) can replace computed tomography (CT) as the standard of care for the evaluation of the femoral sulcus. This was a prospective study comparing the reliability of CT, magnetic resonance (MR), and US for measuring the femoral sulcus in patients with patellar instability. Twenty-four patients were recruited to undergo a CT, MR, and US examination of each knee. Two observers independently measured femoral sulcus angles from subchondral bone and hyaline cartilage on two occasions. Intraclass correlations and generalizability coefficients were calculated to measure the reliability of each of the techniques. Thereafter, two observers measured the femoral sulcus angle from ultrasound images recorded by two independent operators to estimate interobserver and interoperator reliability. Forty-seven knees were examined with CT and US and 44 with MRI. The sulcus angle was consistently smaller when measured from subchondral bone compared to cartilage (5-7 ). Interobserver reliability for CT, MR, and US measurements from subchondral bone were 0.87, 0.80, and 0.82 and from cartilage 0.80, 0.81, and 0.50. Generalizability coefficients of measurements from subchondral bone for CT, MR, and US were 0.87, 0.76, and 0.81 and for cartilage 0.76, 0.73, and 0.05. Most of the variability in the US occurred at image acquisition rather than measurement. In patients with patellar instability, CT and MR are reliable techniques for measuring the femoral sulcus angle but US, particularly of the articular cartilage, is not. MR is therefore the most suitable tool for longitudinal studies of the femoral sulcus. (orig.)

  10. Reliability and validity of the ultrasound technique to measure the rectus femoris muscle diameter in older CAD-patients

    Directory of Open Access Journals (Sweden)

    Thomaes Tom

    2012-04-01

    Full Text Available Abstract Background The increasing age of coronary artery disease (CAD patients and the occurrence of sarcopenia in the elderly population accompanied by 'fear of moving' and hospitalization in these patients often results in a substantial loss of skeletal muscle mass and muscle strength. Cardiac rehabilitation can improve exercise tolerance and muscle strength in CAD patients but less data describe eventual morphological muscular changes possibly by more difficult access to imaging techniques. Therefore the aim of this study is to assess and quantify the reliability and validity of an easy applicable method, the ultrasound (US technique, to measure the diameter of rectus femoris muscle in comparison to the muscle dimensions measured with CT scans. Methods 45 older CAD patients without cardiac event during the last 9 months were included in this study. 25 patients were tested twice with ultrasound with a two day interval to assess test-retest reliability and 20 patients were tested twice (once with US and once with CT on the same day to assess the validity of the US technique compared to CT as the gold standard. Isometric and isokinetic muscle testing was performed to test potential zero-order correlations between muscle diameter, muscle volume and muscle force. Results An intraclass correlation coefficient (ICC of 0.97 ((95%CL: 0.92 - 0.99 was found for the test-retest reliability of US and the ICC computed between US and CT was 0.92 (95%CL: 0.81 - 0.97. The absolute difference between both techniques was 0.01 ± 0.12 cm (p = 0.66 resulting in a typical percentage error of 4.4%. Significant zero-order correlations were found between local muscle volume and muscle diameter assessed with CT (r = 0.67, p = 0.001 and assessed with US (r = 0.49, p Conclusions Ultrasound imaging can be used as a valid and reliable measurement tool to assess the rectus femoris muscle diameter in older CAD patients.

  11. A systematic analysis of backbone amide assignments achieved via combinatorial selective labelling of amino acids

    Energy Technology Data Exchange (ETDEWEB)

    Jeremy Craven, C. [University of Sheffield, Department of Biotechnology and Molecular Biology (United Kingdom); Al-Owais, Moza; Parker, Martin J. [University of Leeds, Astbury Centre for Structural Molecular Biology, Institute of Molecular and Cellular Biology (United Kingdom)], E-mail: m.j.parker@leeds.ac.uk

    2007-06-15

    With the advent of high-yield cell-free expressions systems, many researchers are exploiting selective isotope labelling of amino acids to increase the efficiency and accuracy of the NMR assignment process. We developed recently a combinatorial selective labelling (CSL) method capable of yielding large numbers of residue-type and sequence-specific backbone amide assignments, which involves comparing cross-peak intensities in {sup 1}H-{sup 15}N HSQC and 2D {sup 1}H-{sup 15}N HNCO spectra collected for five samples containing different combinations of {sup 13}C- and {sup 15}N-labelled amino acids [Parker MJ, Aulton-Jones M, Hounslow A, Craven C J (2004) J Am Chem Soc 126:5020-5021]. In this paper we develop a robust method for establishing the reliability of these assignments. We have performed a detailed statistical analysis of the CSL data collected for a model system (the B1 domain of protein G from Streptococcus), developing a scoring method which allows the confidence in assignments to be assessed, and which enables the effects of overlap on assignment fidelity to be predicted. To further test the scoring method and also to assess the performance of CSL in relation to sample quality, we have applied the method to the CSL data collected for GFP in our previous study.

  12. Reliability and safety of functional capacity evaluation in patients with whiplash associated disorders.

    Science.gov (United States)

    Trippolini, M A; Reneman, M F; Jansen, B; Dijkstra, P U; Geertzen, J H B

    2013-09-01

    Whiplash-associated disorders (WAD) are a burden for both individuals and society. It is recommended to evaluate patients with WAD at risk of chronification to enhance rehabilitation and promote an early return to work. In patients with low back pain (LBP), functional capacity evaluation (FCE) contributes to clinical decisions regarding fitness-for-work. FCE should have demonstrated sufficient clinimetric properties. Reliability and safety of FCE for patients with WAD is unknown. Thirty-two participants (11 females and 21 males; mean age 39.6 years) with WAD (Grade I or II) were included. The FCE consisted of 12 tests, including material handling, hand grip strength, repetitive arm movements, static arm activities, walking speed, and a 3 min step test. Overall the FCE duration was 60 min. The test-retest interval was 7 days. Interclass correlations (model 1) (ICCs) and limits of agreement (LoA) were calculated. Safety was assessed by a Pain Response Questionnaire, observation criteria and heart rate monitoring. ICCs ranged between 0.57 (3 min step test) and 0.96 (short two-handed carry). LoA relative to mean performance ranged between 15 % (50 m walking test) and 57 % (lifting waist to overhead). Pain reactions after WAD FCE decreased within days. Observations and heart rate measurements fell within the safety criteria. The reliability of the WAD FCE was moderate in two tests, good in five tests and excellent in five tests. Safety-criteria were fulfilled. Interpretation at the patient level should be performed with care because LoA were substantial.

  13. Reliability and responsiveness of algometry for measuring pressure pain threshold in patients with knee osteoarthritis

    OpenAIRE

    Mutlu, Ebru Kaya; Ozdincler, Arzu Razak

    2015-01-01

    [Purpose] This study aimed to establish the intrarater reliability and responsiveness of a clinically available algometer in patients with knee osteoarthritis as well as to determine the minimum-detectable-change and standard error of measurement of testing to facilitate clinical interpretation of temporal changes. [Subjects] Seventy-three patients with knee osteoarthritis were included. [Methods] Pressure pain threshold measured by algometry was evaluated 3 times at 2-min intervals over 2 cl...

  14. Clinical Functional Capacity Testing in Patients With Facioscapulohumeral Muscular Dystrophy: Construct Validity and Interrater Reliability of Antigravity Tests

    NARCIS (Netherlands)

    Rijken, N.H.M.; Engelen, B.G.M. van; Weerdesteyn, V.G.M.; Geurts, A.C.H.

    2015-01-01

    OBJECTIVE: To evaluate the construct validity and interrater reliability of 4 simple antigravity tests in a small group of patients with facioscapulohumeral muscular dystrophy (FSHD). DESIGN: Case-control study. SETTING: University medical center. PARTICIPANTS: Patients with various severity levels

  15. Validity, reliability and responsiveness of the Body Image Quality of Life Inventory in patients treated for infective endocarditis

    DEFF Research Database (Denmark)

    Rasmussen, Trine Bernholdt; Konradsen, Hanne; Dixon, Jane

    2017-01-01

    been validated in this patient population. The purpose of this study was thus to assess the validity, reliability and responsiveness of the Danish Body Image Quality of Life Inventory (BIQLI-DA) on patients treated for IE. METHODS: We evaluated the psychometric properties of the BIQLI-DA on data......: The BIQLI-DA may be applicable in healthcare research as it seems to be valid, reliable and responsive; however, evidence should be strengthened through further exploration of instrument performance, particularly regarding responsiveness.......: Participants were seventy patients with a mean age of 58 years and of which 83% were men. Results indicated convergent construct validity by confirming hypothesised associations to potentially related constructs. The BIQLI-DA was found to be highly internally consistent with a Cronbach's alpha of 0...

  16. Functional claudication distance: a reliable and valid measurement to assess functional limitation in patients with intermittent claudication

    Directory of Open Access Journals (Sweden)

    Prins Martin H

    2009-03-01

    Full Text Available Abstract Background Disease severity and functional impairment in patients with intermittent claudication is usually quantified by the measurement of pain-free walking distance (intermittent claudication distance, ICD and maximal walking distance (absolute claudication distance, ACD. However, the distance at which a patient would prefer to stop because of claudication pain seems a definition that is more correspondent with the actual daily life walking distance. We conducted a study in which the distance a patient prefers to stop was defined as the functional claudication distance (FCD, and estimated the reliability and validity of this measurement. Methods In this clinical validity study we included patients with intermittent claudication, following a supervised exercise therapy program. The first study part consisted of two standardised treadmill tests. During each test ICD, FCD and ACD were determined. Primary endpoint was the reliability as represented by the calculated intra-class correlation coefficients. In the second study part patients performed a standardised treadmill test and filled out the Rand-36 questionnaire. Spearman's rho was calculated to assess validity. Results The intra-class correlation coefficients of ICD, FCD and ACD were 0.940, 0.959, and 0.975 respectively. FCD correlated significantly with five out of nine domains, namely physical function (rho = 0.571, physical role (rho = 0.532, vitality (rho = 0.416, pain (rho = 0.416 and health change (rho = 0.414. Conclusion FCD is a reliable and valid measurement for determining functional capacity in trained patients with intermittent claudication. Furthermore it seems that FCD better reflects the actual functional impairment. In future studies, FCD could be used alongside ICD and ACD.

  17. The Communication Function Classification System: cultural adaptation, validity, and reliability of the Farsi version for patients with cerebral palsy.

    Science.gov (United States)

    Soleymani, Zahra; Joveini, Ghodsiye; Baghestani, Ahmad Reza

    2015-03-01

    This study developed a Farsi language Communication Function Classification System and then tested its reliability and validity. Communication Function Classification System is designed to classify the communication functions of individuals with cerebral palsy. Up until now, there has been no instrument for assessment of this communication function in Iran. The English Communication Function Classification System was translated into Farsi and cross-culturally modified by a panel of experts. Professionals and parents then assessed the content validity of the modified version. A backtranslation of the Farsi version was confirmed by the developer of the English Communication Function Classification System. Face validity was assessed by therapists and parents of 10 patients. The Farsi Communication Function Classification System was administered to 152 individuals with cerebral palsy (age, 2 to 18 years; median age, 10 years; mean age, 9.9 years; standard deviation, 4.3 years). Inter-rater reliability was analyzed between parents, occupational therapists, and speech and language pathologists. The test-retest reliability was assessed for 75 patients with a 14 day interval between tests. The inter-rater reliability of the Communication Function Classification System was 0.81 between speech and language pathologists and occupational therapists, 0.74 between parents and occupational therapists, and 0.88 between parents and speech and language pathologists. The test-retest reliability was 0.96 for occupational therapists, 0.98 for speech and language pathologists, and 0.94 for parents. The findings suggest that the Farsi version of Communication Function Classification System is a reliable and valid measure that can be used in clinical settings to assess communication function in patients with cerebral palsy. Copyright © 2015 Elsevier Inc. All rights reserved.

  18. Chromogenic assay for BAY 81-8973 potency assignment has no impact on clinical outcome or monitoring in patient samples.

    Science.gov (United States)

    Kitchen, S; Katterle, Y; Beckmann, H; Maas Enriquez, M

    2016-06-01

    Essentials Discrepancies can exist in factor VIII activity measured by the one-stage or chromogenic assays. LEOPOLD trial data were used to assess clinical impact of BAY 81-8973 potency assignment assay. Efficacy was not affected by the assay used for potency assignment and dosing of BAY 81-8973. Either assay may be used to measure factor VIII activity after BAY 81-8973 infusion. Background Product-specific discrepancies have been reported for factor VIII (FVIII) activity determined with one-stage or chromogenic assays. Objective To assess the clinical impact of potency assignment of BAY 81-8973, a full-length, unmodified, recombinant human FVIII, by use of the chromogenic assay or chromogenic assay adjusted to mimic results obtained with the one-stage assay Patients/methods Patients aged 12-65 years with severe hemophilia A received BAY 81-8973 in LEOPOLD I (20-50 IU kg(-1) two or three times weekly [investigator decision]) and LEOPOLD II (randomized to 20-30 IU kg(-1) twice weekly, 30-40 IU kg(-1) three times weekly, or on-demand treatment). Both trials included two 6-month crossover periods in which potency labeling was determined with the chromogenic substrate assay as per the European Pharmacopoeia (CS/EP) or the chromogenic substrate assay adjusted to mimic results obtained with the one-stage assay (CS/ADJ). The annualized bleeding rate (ABR) and FVIII incremental recovery were assessed by the use of pooled data. Results The analysis was perfomed on 121 patients. Median (quartile [Q] 1; Q3) ABRs during the CS/EP and CS/ADJ periods were 1.98 (0; 5.92) and 1.98 (0; 7.34), respectively. The mean incremental recovery was > 2 IU dL(-1) per IU kg(-1) in both periods with the use of either assay for postinfusion FVIII measurements. The median (Q1; Q3) chromogenic/one-stage assay recovery ratio was 1.054 (0.892; 1.150) for the CS/EP period when a plasma standard was used for calibration. Conclusions No impact on the ABR was observed with chromogenic-based as compared

  19. Reliability, validity and description of timed performance of the Jebsen-Taylor Test in patients with muscular dystrophies.

    Science.gov (United States)

    Artilheiro, Mariana Cunha; Fávero, Francis Meire; Caromano, Fátima Aparecida; Oliveira, Acary de Souza Bulle; Carvas, Nelson; Voos, Mariana Callil; Sá, Cristina Dos Santos Cardoso de

    2017-12-08

    The Jebsen-Taylor Test evaluates upper limb function by measuring timed performance on everyday activities. The test is used to assess and monitor the progression of patients with Parkinson disease, cerebral palsy, stroke and brain injury. To analyze the reliability, internal consistency and validity of the Jebsen-Taylor Test in people with Muscular Dystrophy and to describe and classify upper limb timed performance of people with Muscular Dystrophy. Fifty patients with Muscular Dystrophy were assessed. Non-dominant and dominant upper limb performances on the Jebsen-Taylor Test were filmed. Two raters evaluated timed performance for inter-rater reliability analysis. Test-retest reliability was investigated by using intraclass correlation coefficients. Internal consistency was assessed using the Cronbach alpha. Construct validity was conducted by comparing the Jebsen-Taylor Test with the Performance of Upper Limb. The internal consistency of Jebsen-Taylor Test was good (Cronbach's α=0.98). A very high inter-rater reliability (0.903-0.999), except for writing with an Intraclass correlation coefficient of 0.772-1.000. Strong correlations between the Jebsen-Taylor Test and the Performance of Upper Limb Module were found (rho=-0.712). The Jebsen-Taylor Test is a reliable and valid measure of timed performance for people with Muscular Dystrophy. Copyright © 2017 Associação Brasileira de Pesquisa e Pós-Graduação em Fisioterapia. Publicado por Elsevier Editora Ltda. All rights reserved.

  20. Assessing the Construct Validity and Internal Reliability of the Screening Tool Test Your Memory in Patients with Chronic Pain

    Science.gov (United States)

    Ojeda, B.; Salazar, A.; Dueñas, M.; Torres, L. M.; Mico, J. A.; Failde, I.

    2016-01-01

    Patients with chronic pain often complain about cognitive difficulties, and since these symptoms represent an additional source of suffering and distress, evaluating the cognitive status of these patients with valid and reliable tests should be an important part of their overall assessment. Although cognitive impairment is a critical characteristic of pain, there is no specific measure designed to detect these effects in this population. The objective was to analyze the psychometric properties of the “Test Your Memory” (TYM) test in patients with chronic pain of three different origins. A cross-sectional study was carried out on 72 subjects free of pain and 254 patients suffering from different types of chronic pain: neuropathic pain (104), musculoskeletal pain (99) and fibromyalgia (51). The construct validity of the TYM was assessed using the Mini-Mental State Examination (MMSE), Hospital Anxiety and Depression Scale (HADs), Index-9 from MOS-sleep, SF-12, and through the intensity (Visual Analogical Scale) and duration of pain. An exploratory factor analysis was also performed and internal reliability was assessed using Cronbach’s alpha. After adjusting for potential confounders the TYM could distinguish between pain and pain-free patients, and it was correlated with the: MMSE (0.89, pmental components (0.55, p valid and reliable screening instrument to assess cognitive function in chronic pain patients that will be of particular value in clinical situations. PMID:27119165

  1. Assessing the Construct Validity and Internal Reliability of the Screening Tool Test Your Memory in Patients with Chronic Pain.

    Science.gov (United States)

    Ojeda, B; Salazar, A; Dueñas, M; Torres, L M; Mico, J A; Failde, I

    2016-01-01

    Patients with chronic pain often complain about cognitive difficulties, and since these symptoms represent an additional source of suffering and distress, evaluating the cognitive status of these patients with valid and reliable tests should be an important part of their overall assessment. Although cognitive impairment is a critical characteristic of pain, there is no specific measure designed to detect these effects in this population. The objective was to analyze the psychometric properties of the "Test Your Memory" (TYM) test in patients with chronic pain of three different origins. A cross-sectional study was carried out on 72 subjects free of pain and 254 patients suffering from different types of chronic pain: neuropathic pain (104), musculoskeletal pain (99) and fibromyalgia (51). The construct validity of the TYM was assessed using the Mini-Mental State Examination (MMSE), Hospital Anxiety and Depression Scale (HADs), Index-9 from MOS-sleep, SF-12, and through the intensity (Visual Analogical Scale) and duration of pain. An exploratory factor analysis was also performed and internal reliability was assessed using Cronbach's alpha. After adjusting for potential confounders the TYM could distinguish between pain and pain-free patients, and it was correlated with the: MMSE (0.89, pmental components (0.55, p reliable screening instrument to assess cognitive function in chronic pain patients that will be of particular value in clinical situations.

  2. Reliability and minimal detectable change of a modified passive neck flexion test in patients with chronic nonspecific neck pain and asymptomatic subjects.

    Science.gov (United States)

    López-de-Uralde-Villanueva, Ibai; Acuyo-Osorio, Mario; Prieto-Aldana, María; La Touche, Roy

    2017-04-01

    The Passive Neck Flexion Test (PNFT) can diagnose meningitis and potential spinal disorders. Little evidence is available concerning the use of a modified version of the PNFT (mPNFT) in patients with chronic nonspecific neck pain (CNSNP). To assess the reliability of the mPNFT in subjects with and without CNSNP. The secondary objective was to assess the differences in the symptoms provoked by the mPNFT between these two populations. We used repeated measures concordance design for the main objective and cross-sectional design for the secondary objective. A total of 30 asymptomatic subjects and 34 patients with CNSNP were recruited. The following measures were recorded: the range of motion at the onset of symptoms (OS-mPNFT), the range of motion at the submaximal pain (SP-mPNFT), and evoked pain intensity on the mPNFT (VAS-mPNFT). Good to excellent reliability was observed for OS-mPNFT and SP-mPNFT in the asymptomatic group (intra-examiner reliability: 0.95-0.97; inter-examiner reliability: 0.86-0.90; intra-examiner test-retest reliability: 0.84-0.87). In the CNSNP group, a good to excellent reliability was obtained for the OS-mPNFT (intra-examiner reliability: 0.89-0.96; inter-examiner reliability: 0.83-0.86; intra-examiner test-retest reliability: 0.83-0.85) and the SP-PNFT (intra-examiner reliability: 0.94-0.98; inter-examiner reliability: 0.80-0.82; intra-examiner test-retest reliability: 0.88-0.91). The CNSNP group showed statistically significant differences in OS-mPNFT (t = 4.92; P reliable tool regardless of the examiner and the time factor. Patients with CNSNP have a decrease range of motion and more pain than asymptomatic subjects in the mPNFT. This exceeds the minimal detectable changes for OS-mPNFT and VAS-mPNFT. Copyright © 2017 Elsevier Ltd. All rights reserved.

  3. Reliability, validity, and responsiveness of the Persian version of Shoulder Activity Scale in a group of patients with shoulder disorders.

    Science.gov (United States)

    Negahban, Hossein; Mohtasebi, Elham; Goharpey, Shahin

    2015-01-01

    The aim of this methodological study was to cross-culturally translate the Shoulder Activity Scale (SAS) into the Persian and determine its clinimetric properties including reliability, validity, and responsiveness in patients with shoulder disorders. Persian version of the SAS was obtained after standard forward-backward translation. Three questionnaires were completed by the respondents: SAS, shoulder pain and disability index (SPADI), and Short-Form 36 Health Survey (SF-36). The patients completed the SAS, 1 week after the first visit to evaluate the test-retest reliability. Construct validity was evaluated by examining the associations between the scores on the SAS and the scores obtained from the SPADI, SF-36, and age of the patients. To assess responsiveness, data were collected in the first visit and then again after 4 weeks physiotherapy intervention. Test-retest reliability and internal consistency were assessed using Intra-class Correlation Coefficient (ICC) and Cronbach's alpha, respectively. To evaluate construct validity, Spearman's rank correlation was used. The ability of the SAS to detect changes was evaluated by the receiver-operating characteristics method. No problem or language difficulties were reported during translation process. Test-retest reliability of the SAS was excellent with an ICC of 0.98. Also, the marginal Cronbach's alpha level of 0.64 was obtained. The correlation between the SAS and the SPADI was low, proving divergent validity, whereas the correlations between the SAS and the SF-36/age were moderate proving convergent validity. A marginally acceptable responsiveness was achieved for the Persian SAS. The study provides some evidences to support the test-retest reliability, internal consistency, construct validity, and responsiveness of the Persian version of the SAS in patients with shoulder disorders. Therefore, it seems that this instrument is a useful measure of shoulder activity level in research setting and clinical practice

  4. SimPhospho: a software tool enabling confident phosphosite assignment.

    Science.gov (United States)

    Suni, Veronika; Suomi, Tomi; Tsubosaka, Tomoya; Imanishi, Susumu Y; Elo, Laura L; Corthals, Garry L

    2018-03-27

    Mass spectrometry combined with enrichment strategies for phosphorylated peptides has been successfully employed for two decades to identify sites of phosphorylation. However, unambiguous phosphosite assignment is considered challenging. Given that site-specific phosphorylation events function as different molecular switches, validation of phosphorylation sites is of utmost importance. In our earlier study we developed a method based on simulated phosphopeptide spectral libraries, which enables highly sensitive and accurate phosphosite assignments. To promote more widespread use of this method, we here introduce a software implementation with improved usability and performance. We present SimPhospho, a fast and user-friendly tool for accurate simulation of phosphopeptide tandem mass spectra. Simulated phosphopeptide spectral libraries are used to validate and supplement database search results, with a goal to improve reliable phosphoproteome identification and reporting. The presented program can be easily used together with the Trans-Proteomic Pipeline and integrated in a phosphoproteomics data analysis workflow. SimPhospho is available for Windows, Linux and Mac operating systems at https://sourceforge.net/projects/simphospho/. It is open source and implemented in C ++. A user's manual with detailed description of data analysis using SimPhospho as well as test data can be found as supplementary material of this article. Supplementary data are available at https://www.btk.fi/research/ computational-biomedicine/software/.

  5. The reliability and validity of the standardized Mensendieck test in relation to disability in patients with chronic pain.

    Science.gov (United States)

    Keessen, Paul; Maaskant, Jolanda; Visser, Bart

    2018-08-01

    The standardized Mensendieck test (SMT) was developed to quantify posture, movement, gait, and respiration. In the hands of an experienced therapist, the SMT is proven to be a reliable tool. It is unclear whether posture, movement, gait, and respiration are related to the degree of functional disability in patients with chronic pain. The objective of this study was to assess the reliability and convergent validity of the SMT in a heterogeneous sample of 50 patients with chronic pain. Internal consistency was determined by Cronbach's α and interrater reliability by the intraclass correlation coefficient (ICC). Convergent validity was assessed by determining the Spearman rank correlation coefficient between the movement quality measured in the SMT and functional limitation measured on the disability rating index (DRI). The internal consistency was Cronbach's α 0.91. Substantial reliability was found for the items: movement (ICC = 0.68), gait (ICC = 0.69), sitting posture (ICC = 0.63), and respiration (ICC = 0.64). Insufficient reliability was found for standing posture (ICC = 0.23). A moderate correlation was found between average test score SMT and the DRI (r = -0.37) and respiration and DRI (r = -0.45). The SMT is a reasonably reliable tool to assess movement, gait, sitting posture, and respiration. None of the items in the domain standing posture has sufficient reliability. A thorough study of this domain should be considered. The results show little evidence for convergent validity. Several items of the SMT correlated moderately with functional limitation with the DRI. These items were global movement, hip flexion, pelvis rotation, and all respiration items.

  6. Reliability and Validity of the Beijing Version of the Montreal Cognitive Assessment in the Evaluation of Cognitive Function of Adult Patients with OSAHS.

    Science.gov (United States)

    Chen, Xiong; Zhang, Rui; Xiao, Ying; Dong, Jiaqi; Niu, Xun; Kong, Weijia

    2015-01-01

    The patients with obstructive sleep apnea hypopnea syndrome (OSAHS) tend to develop cognitive deficits, which usually go unrecognized, and can affect their daily life. The Beijing version of the Montreal cognitive assessment (MoCA-BJ), a Chinese version of MoCA, has been used for the assessment of cognitive functions of OSAHS patients in clinical practice. So far, its reliability and validity have not been tested. This study examined the reliability and validity of MoCA-BJ in a cohort of adult OSAHS patients. 152 OSAHS patients, ranging from mild, moderate to severe, 49 primary snoring subjects and 40 normal controls were evaluated for cognitive functions by employing both MoCA-BJ and the Mini Mental State Examination (MMSE). Forty of them were re-tested by MoCA-BJ 14 days after the first test. Internal consistency, test-retest reliability, discriminate and concurrent validity of MoCA-BJ were analyzed. Internal consistency reliability by Cronbach's alpha was adequate (0.73). Intra-class correlation coefficient (ICC), an measure of test-retest reliability, was 0.87 (Preliable and stable. The MoCA-BJ was capable of detecting cognitive dysfunction by visuospatial and total MoCA-BJ score.

  7. Intra-rater reliability and agreement of muscle strength, power and functional performance measures in patients with hip osteoarthritis

    DEFF Research Database (Denmark)

    Bieler, Theresa; Magnusson, S Peter; Kjær, Michael

    2014-01-01

    OBJECTIVE: To investigate the reliability and agreement of measures of lower extremity muscle strength, power and functional performance in patients with hip osteoarthritis at different time intervals, and to compare these with the same measures in healthy peers. DESIGN: Intra-rater test...... extensor power, and functional performance (8-foot Up & Go, stair climbing, chair stand and 6-min walk) were measured in patients, and quadriceps strength, leg extensor power and functional performance were measured in healthy peers. Systematic error, reliability and agreement were calculated. RESULTS......-retest separated by 1, 2, or 2.5 weeks in patients, and 1 week in healthy peers. SUBJECTS: Patients with hip osteoarthritis (age range 61-83 years) with 1 (n = 37), 2 (n = 35), or 2.5 weeks (n = 15) between tests, and 35 healthy peers (age range 63-82 years). METHODS: Maximal isometric hip and thigh strength, leg...

  8. Test-retest reliability of Antonovsky's 13-item sense of coherence scale in patients with hand-related disorders

    DEFF Research Database (Denmark)

    Hansen, Alice Ørts; Kristensen, Hanne Kaae; Cederlund, Ragnhild

    2017-01-01

    to be a powerful tool to measure the ICF component personal factors, which could have an impact on patients' rehabilitation outcomes. Implications for rehabilitation Antonovsky's SOC-13 scale showed test-retest reliability for patients with hand-related disorders. The SOC-13 scale could be a suitable tool to help...... measure personal factors....

  9. Test-retest reliability and minimal detectable change of two simplified 3-point balance measures in patients with stroke.

    Science.gov (United States)

    Chen, Yi-Miau; Huang, Yi-Jing; Huang, Chien-Yu; Lin, Gong-Hong; Liaw, Lih-Jiun; Lee, Shih-Chieh; Hsieh, Ching-Lin

    2017-10-01

    The 3-point Berg Balance Scale (BBS-3P) and 3-point Postural Assessment Scale for Stroke Patients (PASS-3P) were simplified from the BBS and PASS to overcome the complex scoring systems. The BBS-3P and PASS-3P were more feasible in busy clinical practice and showed similarly sound validity and responsiveness to the original measures. However, the reliability of the BBS-3P and PASS-3P is unknown limiting their utility and the interpretability of scores. We aimed to examine the test-retest reliability and minimal detectable change (MDC) of the BBS-3P and PASS-3P in patients with stroke. Cross-sectional study. The rehabilitation departments of a medical center and a community hospital. A total of 51 chronic stroke patients (64.7% male). Both balance measures were administered twice 7 days apart. The test-retest reliability of both the BBS-3P and PASS-3P were examined by intraclass correlation coefficients (ICC). The MDC and its percentage over the total score (MDC%) of each measure was calculated for examining the random measurement errors. The ICC values of the BBS-3P and PASS-3P were 0.99 and 0.97, respectively. The MDC% (MDC) of the BBS-3P and PASS-3P were 9.1% (5.1 points) and 8.4% (3.0 points), respectively, indicating that both measures had small and acceptable random measurement errors. Our results showed that both the BBS-3P and the PASS-3P had good test-retest reliability, with small and acceptable random measurement error. These two simplified 3-level balance measures can provide reliable results over time. Our findings support the repeated administration of the BBS-3P and PASS-3P to monitor the balance of patients with stroke. The MDC values can help clinicians and researchers interpret the change scores more precisely.

  10. Reliability, validity and responsiveness of the German self-reported foot and ankle score (SEFAS) in patients with foot or ankle surgery.

    Science.gov (United States)

    Arbab, Dariusch; Kuhlmann, Katharina; Schnurr, Christoph; Bouillon, Bertil; Lüring, Christian; König, Dietmar

    2017-10-10

    Patient-reported outcome measures are a critical tool in evaluating the efficacy of orthopedic procedures and are increasingly used in clinical trials to assess outcomes of health care. The intention of this study was to develop and culturally adapt a German version of the Self-reported Foot and Ankle Score (SEFAS) and to evaluate reliability, validity and responsiveness. According to Cross Cultural Adaptation of Self-Reported Measure guidelines forward and backward translation has been performed. The German SEFAS was investigated in 177 consecutive patients. 177 Patients completed the German SEFAS, Foot and Ankle Outcome Score (FAOS), Short-Form 36 and numeric scales for pain and disability (NRS) before and 118 patients 6 months after foot or ankle surgery. Test-Retest reliability, internal consistency, floor and ceiling effects, construct validity and minimal important change were analyzed. The German SEFAS demonstrated excellent test-retest reliability with ICC values of 0.97. Cronbach's alpha (α) value of 0.89 demonstrated strong internal consistency. No floor or ceiling effects were observed for the German version of the SEFAS. As hypothesized SEFAS correlated strongly with FAOS and SF-36 domains. It showed moderate (ES/SRM > 0.5) responsiveness between preoperative assessment and postoperative follow-up. The German version of the SEFAS demonstrated good psychometric properties. It proofed to be a valid and reliable instrument for use in foot and ankle patients. DRKS00007585.

  11. Geographical assignment of hospitalists in an urban teaching hospital: feasibility and impact on efficiency and provider satisfaction.

    Science.gov (United States)

    Bryson, Christine; Boynton, Greta; Stepczynski, Anna; Garb, Jane; Kleppel, Reva; Irani, Farzan; Natanasabapathy, Siva; Stefan, Mihaela S

    2017-10-01

    To evaluate whether implementation of a geographic model of assigning hospitalists is feasible and sustainable in a large hospitalist program and assess its impact on provider satisfaction, perceived efficiency and patient outcomes. Pre (3 months) - post (12 months) intervention study conducted from June 2014 through September 2015 at a tertiary care medical center with a large hospitalist program caring for patients scattered in 4 buildings and 16 floors. Hospitalists were assigned to a particular nursing unit (geographic assignment) with a goal of having over 80% of their assigned patients located on their assigned unit. Satisfaction and perceived efficiency were assessed through a survey administered before and after the intervention. Geographic assignment percentage increased from an average of 60% in the pre-intervention period to 93% post-intervention. The number of hospitalists covering a 32 bed unit decreased from 8-10 pre to 2-3 post-intervention. A majority of physicians (87%) thought that geography had a positive impact on the overall quality of care. Respondents reported that they felt that geography increased time spent with patient/caregivers to discuss plan of care (p < 0.001); improved communication with nurses (p = 0.0009); and increased sense of teamwork with nurses/case managers (p < 0.001). Mean length of stay (4.54 vs 4.62 days), 30-day readmission rates (16.0% vs 16.6%) and patient satisfaction (79.9 vs 77.3) did not change significantly between the pre- and post-implementation period. The discharge before noon rate improved slightly (47.5% - 54.1%). Implementation of a unit-based model in a large hospitalist program is feasible and sustainable with appropriate planning and support. The geographical model of care increased provider satisfaction and perceived efficiency; it also facilitated the implementation of other key interventions such as interdisciplinary rounds.

  12. The reliability and validity of using the urine dipstick test by patient self-assessment for urinary tract infection screening in spinal cord injury patients.

    Science.gov (United States)

    Duanngai, Krit; Sirasaporn, Patpiya; Ngaosinchai, Siriwan Surapaitoon

    2017-01-01

    The aim of this is to evaluate the reliability of the urine dipstick test by patients' self-assessment for urinary tract infection (UTI) screening and to determine the validity of urine dipstick test. Rehabilitation Department, Srinagarind Hospital, Thailand. A diagnostic study. This study compared the urine dipstick test (index test) with the National Institute on Disability and Rehabilitation Research (NIDRR) criteria (gold standard test) in spinal cord injury (SCI) patients. The urine dipstick test informed positive and negative results. Besides the NIDRR criteria classified as UTI and no UTI. The interrater reliability was measured in the sense of Kappa whereas the validity of urine dipstick test was reported in terms of sensitivity, specificity, positive likelihood ratio (LR) (+LR), negative LR (-LR), positive predictive value (PPV), and negative predictive value (NPV). Out of the 56 participants, the kappa of urine dipstick test for leukocyte esterase, nitrite, and combined leukocyte esterase and nitrite were 0.09, 0.21, and 0.52, respectively. The nitrite urine dipstick test showed the highest sensitivity (90%). The combined leukocyte esterase and nitrite urine dipstick test gave the highest specificity (87%), PPV (60%), NPV (93%), and +LR (5.63). The interrater reliability of combined leukocyte esterase and nitrite urine dipstick test was moderate agreement. The combined leukocyte esterase and nitrite urine dipstick test showed high level of both sensitivity and specificity. The combined leukocyte esterase and nitrite urine dipstick test should be promoted for patients' self-assessment for UTI screening in SCI patients.

  13. Psychometric Properties of Difficulties of Working with Patients with Personality Disorders and Attitudes Towards Patients with Personality Disorders Scales.

    Science.gov (United States)

    Eren, Nurhan

    2014-12-01

    In this study, we aimed to develop two reliable and valid assessment instruments for investigating the level of difficulties mental health workers experience while working with patients with personality disorders and the attitudes they develop tt the patients. The research was carried out based on the general screening model. The study sample consisted of 332 mental health workers in several mental health clinics of Turkey, with a certain amount of experience in working with personality disorders, who were selected with a random assignment method. In order to collect data, the Personal Information Questionnaire, Difficulty of Working with Personality Disorders Scale (PD-DWS), and Attitudes Towards Patients with Personality Disorders Scale (PD-APS), which are being examined for reliability and validity, were applied. To determine construct validity, the Adjective Check List, Maslach Burnout Inventory, and State and Trait Anxiety Inventory were used. Explanatory factor analysis was used for investigating the structural validity, and Cronbach alpha, Spearman-Brown, Guttman Split-Half reliability analyses were utilized to examine the reliability. Also, item reliability and validity computations were carried out by investigating the corrected item-total correlations and discriminative indexes of the items in the scales. For the PD-DWS KMO test, the value was .946; also, a significant difference was found for the Bartlett sphericity test (pKMO, the value was .925; a significant difference was found in Bartlett sphericity test (p<.001); the computed reliability coefficient based on continuity was .806; and the Cronbach alpha value of the total test score was .913. Analyses on both scales were based on total scores. It was found that PD-DWS and PD-APS have good psychometric properties, measuring the structure that is being investigated, are compatible with other scales, have high levels of internal reliability between their items, and are consistent across time. Therefore

  14. Controversies of Sex Re-assignment in Genetic Males with Congenital Inadequacy of the Penis.

    Science.gov (United States)

    Raveenthiran, Venkatachalam

    2017-09-01

    Sex assignment in 46XY genetic male children with congenital inadequacy of the penis (CIP) is controversial. Traditionally, children with penile length less than 2 cm at birth are considered unsuitable to be raised as males. They are typically re-assigned to female-sex and feminizing genitoplasty is usually done in infancy. However, the concept of cerebral androgen imprinting has caused paradigm shift in the philosophy of sex re-assignment. Masculinization of the brain, rather than length of the penis, is the modern criterion of sex re-assignment in CIP. This review summarizes the current understanding of the complex issue. In 46XY children with CIP, male-sex assignment appears appropriate in non-hormonal conditions such as idiopathic micropenis, aphallia and exstrophy. Female-sex re-assignment appears acceptable in complete androgen insensitivity (CAIS), while partial androgen insensitivity syndrome (PAIS) patients are highly dissatisfied with the assignment of either sex. Children with 5-alpha reductase deficiency are likely to have spontaneous penile lengthening at puberty. Hence, they are better raised as males. Although female assignment is common in pure gonadal dysgenesis, long-term results are not known to justify the decision.

  15. Validity and reliability of the persian version of templer death anxiety scale in family caregivers of cancer patients.

    Science.gov (United States)

    Soleimani, Mohammad Ali; Bahrami, Nasim; Yaghoobzadeh, Ameneh; Banihashemi, Hedieh; Nia, Hamid Sharif; Haghdoost, Ali Akbar

    2016-01-01

    Due to increasing recognition of the importance of death anxiety for understanding human nature, it is important that researchers who investigate death anxiety have reliable and valid methodology to measure. The purpose of this study was to evaluate the validity and reliability of the Persian version of Templer Death Anxiety Scale (TDAS) in family caregivers of cancer patients. A sample of 326 caregivers of cancer patients completed a 15-item questionnaire. Principal components analysis (PCA) followed by a varimax rotation was used to assess factor structure of the DAS. The construct validity of the scale was assessed using exploratory and confirmatory factor analyses. Convergent and discriminant validity were also examined. Reliability was assessed with Cronbach's alpha coefficients and construction reliability. Based on the results of the PCA and consideration of the meaning of our items, a three-factor solution, explaining 60.38% of the variance, was identified. A confirmatory factor analysis (CFA) then supported the adequacy of the three-domain structure of the DAS. Goodness-of-fit indices showed an acceptable fit overall with the full model {χ(2)(df) = 262.32 (61), χ(2)/df = 2.04 [adjusted goodness of fit index (AGFI) = 0.922, parsimonious comparative fit index (PCFI) = 0.703, normed fit Index (NFI) = 0.912, CMIN/DF = 2.048, root mean square error of approximation (RMSEA) = 0.055]}. Convergent and discriminant validity were shown with construct fulfilled. The Cronbach's alpha and construct reliability were greater than 0.70. The findings show that the Persian version of the TDAS has a three-factor structure and acceptable validity and reliability.

  16. Online patient information on Vagus Nerve Stimulation: How reliable is it for facilitating shared decision making?

    Science.gov (United States)

    Ved, Ronak; Cobbold, Naomi; Igbagiri, Kueni; Willis, Mark; Leach, Paul; Zaben, Malik

    2017-08-01

    This study evaluates the quality of information available on the internet for carers of children with epilepsy considering treatment with Vagus Nerve Stimulation (VNS). Selected key phrases were entered into two popular search engines (Google™, Yahoo™). These phrases were: "Vagus nerve stimulator", alone and in combination with "childhood epilepsy", "paediatric epilepsy" and "epilepsy in childhood"; "VNS", and "VNS epilepsy". The first 50 hits per search were then screened. Of 600 identified sites, duplicated (262), irrelevant (230) and inaccessible (15) results were excluded. 93 websites were identified for evaluation using the DISCERN instrument, an online validation tool for patient information websites. The mean DISCERN score of all analysed websites was 39/80 (49%; SD 13.5). This equates to Fair to borderline Poor global quality, (Excellent=80-63; Good=62-51; Fair=50-39; Poor=38-27; Very poor=26-15). None of the analysed sites obtained an Excellent quality rating. 13% (12) obtained a Good score, 40% (37) obtained an Average score, 35% (33) obtained a Poor score, and 12% (11) obtained a Very poor score. The cohort of websites scored particularly poorly on assessment of whether reliable, holistic information was presented, for instance provision of reliable sources, (28%, SD 18) and discussion of alternative treatments, (30%, SD 14). To facilitate patient-centred shared decision-making, high quality information needs to be available for patients and families considering VNS. This study identifies that such information is difficult to locate on the internet. There is a need to develop focussed and reliable online patient resources for VNS. Copyright © 2017 British Epilepsy Association. Published by Elsevier Ltd. All rights reserved.

  17. Reliability assessment and correlation analysis of evaluating orthodontic treatment outcome in Chinese patients

    OpenAIRE

    Song, Guang-Ying; Zhao, Zhi-He; Ding, Yin; Bai, Yu-Xing; Wang, Lin; He, Hong; Shen, Gang; Li, Wei-Ran; Baumrind, Sheldon; Geng, Zhi; Xu, Tian-Min

    2013-01-01

    This study aimed to assess the reliability of experienced Chinese orthodontists in evaluating treatment outcome and to determine the correlations between three diagnostic information sources. Sixty-nine experienced Chinese orthodontic specialists each evaluated the outcome of orthodontic treatment of 108 Chinese patients. Three different information sources: study casts (SC), lateral cephalometric X-ray images (LX) and facial photographs (PH) were generated at the end of treatment for 108 pat...

  18. Fluidity models in ancient Greece and current practices of sex assignment.

    Science.gov (United States)

    Chen, Min-Jye; McCann-Crosby, Bonnie; Gunn, Sheila; Georgiadis, Paraskevi; Placencia, Frank; Mann, David; Axelrad, Marni; Karaviti, L P; McCullough, Laurence B

    2017-06-01

    Disorders of sexual differentiation such as androgen insensitivity and gonadal dysgenesis can involve an intrinsic fluidity at different levels, from the anatomical and biological to the social (gender) that must be considered in the context of social constraints. Sex assignment models based on George Engel's biopsychosocial aspects model of biology accept fluidity of gender as a central concept and therefore help establish expectations within the uncertainty of sex assignment and anticipate potential changes. The biology underlying the fluidity inherent to these disorders should be presented to parents at diagnosis, an approach that the gender medicine field should embrace as good practice. Greek mythology provides many accepted archetypes of change, and the ancient Greek appreciation of metamorphosis can be used as context with these patients. Our goal is to inform expertise and optimal approaches, knowing that this fluidity may eventually necessitate sex reassignment. Physicians should provide sex assignment education based on different components of sexual differentiation, prepare parents for future hormone-triggered changes in their children, and establish a sex-assignment algorithm. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. Fluidity models in ancient Greece and current practices of sex assignment

    Science.gov (United States)

    Chen, Min-Jye; McCann-Crosby, Bonnie; Gunn, Sheila; Georgiadis, Paraskevi; Placencia, Frank; Mann, David; Axelrad, Marni; Karaviti, L.P; McCullough, Laurence B.

    2018-01-01

    Disorders of sexual differentiation such as androgen insensitivity and gonadal dysgenesis can involve an intrinsic fluidity at different levels, from the anatomical and biological to the social (gender) that must be considered in the context of social constraints. Sex assignment models based on George Engel’s biopsychosocial aspects model of biology accept fluidity of gender as a central concept and therefore help establish expectations within the uncertainty of sex assignment and anticipate potential changes. The biology underlying the fluidity inherent to these disorders should be presented to parents at diagnosis, an approach that the gender medicine field should embrace as good practice. Greek mythology provides many accepted archetypes of change, and the ancient Greek appreciation of metamorphosis can be used as context with these patients. Our goal is to inform expertise and optimal approaches, knowing that this fluidity may eventually necessitate sex reassignment. Physicians should provide sex assignment education based on different components of sexual differentiation, prepare parents for future hormone-triggered changes in their children, and establish a sex-assignment algorithm. PMID:28478088

  20. Validity and reliability of the Cognitive Complaints in Bipolar Disorder Rating Assessment (COBRA) in Japanese patients with bipolar disorder.

    Science.gov (United States)

    Toyoshima, Kuniyoshi; Fujii, Yutaka; Mitsui, Nobuyuki; Kako, Yuki; Asakura, Satoshi; Martinez-Aran, Anabel; Vieta, Eduard; Kusumi, Ichiro

    2017-08-01

    In Japan, there are currently no reliable rating scales for the evaluation of subjective cognitive impairment in patients with bipolar disorder. We studied the relationship between the Japanese version of the Cognitive Complaints in Bipolar Disorder Rating Assessment (COBRA) and objective cognitive assessments in patients with bipolar disorder. We further assessed the reliability and validity of the COBRA. Forty-one patients, aged 16-64, in a remission period of bipolar disorder were recruited from Hokkaido University Hospital in Sapporo, Japan. The COBRA (Japanese version) and Frankfurt Complaint Questionnaire (FCQ), the gold standard in subjective cognitive assessment, were administered. A battery of neuropsychological tests was employed to measure objective cognitive impairment. Correlations among the COBRA, FCQ, and neuropsychological tests were determined using Spearman's correlation coefficient. The Japanese version of the COBRA had high internal consistency, good retest reliability, and concurrent validity-as indicated by a strong correlation with the FCQ. A significant correlation was also observed between the COBRA and objective cognitive measurements of processing speed. These findings are the first to demonstrate that the Japanese version of the COBRA may be clinically useful as a subjective cognitive impairment rating scale in Japanese patients with bipolar disorder. Copyright © 2017 Elsevier Ireland Ltd. All rights reserved.

  1. Test-retest reliability and four-week changes in cardiopulmonary fitness in stroke patients: evaluation using a robotics-assisted tilt table.

    Science.gov (United States)

    Saengsuwan, Jittima; Berger, Lucia; Schuster-Amft, Corina; Nef, Tobias; Hunt, Kenneth J

    2016-09-06

    Exercise testing devices for evaluating cardiopulmonary fitness in patients with severe disability after stroke are lacking, but we have adapted a robotics-assisted tilt table (RATT) for cardiopulmonary exercise testing (CPET). Using the RATT in a sample of patients after stroke, this study aimed to investigate test-retest reliability and repeatability of CPET and to prospectively investigate changes in cardiopulmonary outcomes over a period of four weeks. Stroke patients with all degrees of disability underwent 3 separate CPET sessions: 2 tests at baseline (TB1 and TB2) and 1 test at follow up (TF). TB1 and TB2 were at least 24 h apart. TB2 and TF were 4 weeks apart. A RATT equipped with force sensors in the thigh cuffs, a work rate estimation algorithm and a real-time visual feedback system was used to guide the patients' exercise work rate during CPET. Test-retest reliability and repeatability of CPET variables were analysed using paired t-tests, the intraclass correlation coefficient (ICC), the coefficient of variation (CoV), and Bland and Altman limits of agreement. Changes in cardiopulmonary fitness during four weeks were analysed using paired t-tests. Seventeen sub-acute and chronic stroke patients (age 62.7 ± 10.4 years [mean ± SD]; 8 females) completed the test sessions. The median time post stroke was 350 days. There were 4 severely disabled, 1 moderately disabled and 12 mildly disabled patients. For test-retest, there were no statistically significant differences between TB1 and TB2 for most CPET variables. Peak oxygen uptake, peak heart rate, peak work rate and oxygen uptake at the ventilatory anaerobic threshold (VAT) and respiratory compensation point (RCP) showed good to excellent test-retest reliability (ICC 0.65-0.94). For all CPET variables, CoV was 4.1-14.5 %. The mean difference was close to zero in most of the CPET variables. There were no significant changes in most cardiopulmonary performance parameters during the 4-week period

  2. Children's assignment of grammatical roles in the online processing of Mandarin passive sentences.

    Science.gov (United States)

    Huang, Yi Ting; Zheng, Xiaobei; Meng, Xiangzhi; Snedeker, Jesse

    2013-11-01

    Children's difficulty understanding passives in English has been attributed to the syntactic complexity, overall frequency, cue reliability, and/or incremental processing of this construction. To understand the role of these factors, we used the visual-world paradigm to examine comprehension in Mandarin Chinese where passives are infrequent but signaled by a highly valid marker (BEI). Eye-movements during sentences indicated that these markers triggered incremental role assignments in adults and 5-year-olds. Actions after sentences indicated that passives were often misinterpreted as actives when markers appeared after the referential noun (" Seal BEI it eat " → The seal is eaten by it). However, they were more likely to be interpreted correctly when markers appeared before (" It BEI seal eat " → It is eaten by the seal). The actions and the eye-movements suggest that for both adults and children, interpretations of passive are easier when they do not require revision of an earlier role assignment.

  3. Neural substrates of reliability-weighted visual-tactile multisensory integration

    Directory of Open Access Journals (Sweden)

    Michael S Beauchamp

    2010-06-01

    Full Text Available As sensory systems deteriorate in aging or disease, the brain must relearn the appropriate weights to assign each modality during multisensory integration. Using blood-oxygen level dependent functional magnetic resonance imaging (BOLD fMRI of human subjects, we tested a model for the neural mechanisms of sensory weighting, termed “weighted connections”. This model holds that the connection weights between early and late areas vary depending on the reliability of the modality, independent of the level of early sensory cortex activity. When subjects detected viewed and felt touches to the hand, a network of brain areas was active, including visual areas in lateral occipital cortex, somatosensory areas in inferior parietal lobe, and multisensory areas in the intraparietal sulcus (IPS. In agreement with the weighted connection model, the connection weight measured with structural equation modeling between somatosensory cortex and IPS increased for somatosensory-reliable stimuli, and the connection weight between visual cortex and IPS increased for visual-reliable stimuli. This double dissociation of connection strengths was similar to the pattern of behavioral responses during incongruent multisensory stimulation, suggesting that weighted connections may be a neural mechanism for behavioral reliability weighting.for behavioral reliability weighting.

  4. Reliability of procedures used for scaling loudness

    DEFF Research Database (Denmark)

    Jesteadt, Walt; Joshi, Suyash Narendra

    2013-01-01

    In this study, 16 normally-hearing listeners judged the loudness of 1000-Hz sinusoids using magnitude estimation (ME), magnitude production (MP), and categorical loudness scaling (CLS). Listeners in each of four groups completed the loudness scaling tasks in a different sequence on the first visit...... (ME, MP, CLS; MP, ME, CLS; CLS, ME, MP; CLS, MP, ME), and the order was reversed on the second visit. This design made it possible to compare the reliability of estimates of the slope of the loudness function across procedures in the same listeners. The ME data were well fitted by an inflected...... results were the most reproducible, they do not provide direct information about the slope of the loudness function because the numbers assigned to CLS categories are arbitrary. This problem can be corrected by using data from the other procedures to assign numbers that are proportional to loudness...

  5. Neurology objective structured clinical examination reliability using generalizability theory.

    Science.gov (United States)

    Blood, Angela D; Park, Yoon Soo; Lukas, Rimas V; Brorson, James R

    2015-11-03

    This study examines factors affecting reliability, or consistency of assessment scores, from an objective structured clinical examination (OSCE) in neurology through generalizability theory (G theory). Data include assessments from a multistation OSCE taken by 194 medical students at the completion of a neurology clerkship. Facets evaluated in this study include cases, domains, and items. Domains refer to areas of skill (or constructs) that the OSCE measures. G theory is used to estimate variance components associated with each facet, derive reliability, and project the number of cases required to obtain a reliable (consistent, precise) score. Reliability using G theory is moderate (Φ coefficient = 0.61, G coefficient = 0.64). Performance is similar across cases but differs by the particular domain, such that the majority of variance is attributed to the domain. Projections in reliability estimates reveal that students need to participate in 3 OSCE cases in order to increase reliability beyond the 0.70 threshold. This novel use of G theory in evaluating an OSCE in neurology provides meaningful measurement characteristics of the assessment. Differing from prior work in other medical specialties, the cases students were randomly assigned did not influence their OSCE score; rather, scores varied in expected fashion by domain assessed. © 2015 American Academy of Neurology.

  6. Test-Retest Reliability and Minimal Detectable Change of the D2 Test of Attention in Patients with Schizophrenia.

    Science.gov (United States)

    Lee, Posen; Lu, Wen-Shian; Liu, Chin-Hsuan; Lin, Hung-Yu; Hsieh, Ching-Lin

    2017-12-08

    The d2 Test of Attention (D2) is a commonly used measure of selective attention for patients with schizophrenia. However, its test-retest reliability and minimal detectable change (MDC) are unknown in patients with schizophrenia, limiting its utility in both clinical and research settings. The aim of the present study was to examine the test-retest reliability and MDC of the D2 in patients with schizophrenia. A rater administered the D2 on 108 patients with schizophrenia twice at a 1-month interval. Test-retest reliability was determined through the calculation of the intra-class correlation coefficient (ICC). We also carried out Bland-Altman analysis, which included a scatter plot of the differences between test and retest against their mean. Systematic biases were evaluated by use of a paired t-test. The ICCs for the D2 ranged from 0.78 to 0.94. The MDCs (MDC%) of the seven subscores were 102.3 (29.7), 19.4 (85.0), 7.2 (94.6), 21.0 (69.0), 104.0 (33.1), 105.0 (35.8), and 7.8 (47.8), which represented limited-to-acceptable random measurement error. Trends in the Bland-Altman plots of the omissions (E1), commissions (E2), and errors (E) were noted, presenting that the data had heteroscedasticity. According to the results, the D2 had good test-retest reliability, especially in the scores of TN, TN-E, and CP. For the further research, finding a way to improve the administration procedure to reduce random measurement error would be important for the E1, E2, E, and FR subscores. © The Author(s) 2017. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  7. Intra-Rater, Inter-Rater and Test-Retest Reliability of an Instrumented Timed Up and Go (iTUG Test in Patients with Parkinson's Disease.

    Directory of Open Access Journals (Sweden)

    Rob C van Lummel

    Full Text Available The "Timed Up and Go" (TUG is a widely used measure of physical functioning in older people and in neurological populations, including Parkinson's Disease. When using an inertial sensor measurement system (instrumented TUG [iTUG], the individual components of the iTUG and the trunk kinematics can be measured separately, which may provide relevant additional information.The aim of this study was to determine intra-rater, inter-rater and test-retest reliability of the iTUG in patients with Parkinson's Disease.Twenty eight PD patients, aged 50 years or older, were included. For the iTUG the DynaPort Hybrid (McRoberts, The Hague, The Netherlands was worn at the lower back. The device measured acceleration and angular velocity in three directions at a rate of 100 samples/s. Patients performed the iTUG five times on two consecutive days. Repeated measurements by the same rater on the same day were used to calculate intra-rater reliability. Repeated measurements by different raters on the same day were used to calculate intra-rater and inter-rater reliability. Repeated measurements by the same rater on different days were used to calculate test-retest reliability.Nineteen ICC values (15% were ≥ 0.9 which is considered as excellent reliability. Sixty four ICC values (49% were ≥ 0.70 and < 0.90 which is considered as good reliability. Thirty one ICC values (24% were ≥ 0.50 and < 0.70, indicating moderate reliability. Sixteen ICC values (12% were ≥ 0.30 and < 0.50 indicating poor reliability. Two ICT values (2% were < 0.30 indicating very poor reliability.In conclusion, in patients with Parkinson's disease the intra-rater, inter-rater, and test-retest reliability of the individual components of the instrumented TUG (iTUG was excellent to good for total duration and for turning durations, and good to low for the sub durations and for the kinematics of the SiSt and StSi. The results of this fully automated analysis of instrumented TUG movements

  8. More than just a mouse click: research into work practices behind the assignment of medical trust marks on the World Wide Web.

    Science.gov (United States)

    Adams, Samantha A; de Bont, Antoinette A

    2007-06-01

    Hyperlinked web trust marks have been a popular topic of discussion during the past 10 years. However, the discussion has focused mostly on what these trust marks are not doing in terms of helping patients (or other lay end users) find reliable medical information on the web. In this paper, we discuss how this focus on patients and their actions with respect to trust marks, has overshadowed, if not rendered invisible, what trust marks are doing to educate medical site/information providers. We draw on data from ethnographic research conducted at the Health on the Net Foundation in 2002 and 2003 in order to explore an alternate definition of what it means to be a 'user' of a trust mark and the importance of the review process in educating site providers. We argue that understanding the work involved in the process of assigning a seal is crucial to understanding the role that the seal plays as part of the medical internet.

  9. Monitoring sedation status over time in ICU patients: reliability and validity of the Richmond Agitation-Sedation Scale (RASS).

    Science.gov (United States)

    Ely, E Wesley; Truman, Brenda; Shintani, Ayumi; Thomason, Jason W W; Wheeler, Arthur P; Gordon, Sharon; Francis, Joseph; Speroff, Theodore; Gautam, Shiva; Margolin, Richard; Sessler, Curtis N; Dittus, Robert S; Bernard, Gordon R

    2003-06-11

    Goal-directed delivery of sedative and analgesic medications is recommended as standard care in intensive care units (ICUs) because of the impact these medications have on ventilator weaning and ICU length of stay, but few of the available sedation scales have been appropriately tested for reliability and validity. To test the reliability and validity of the Richmond Agitation-Sedation Scale (RASS). Prospective cohort study. Adult medical and coronary ICUs of a university-based medical center. Thirty-eight medical ICU patients enrolled for reliability testing (46% receiving mechanical ventilation) from July 21, 1999, to September 7, 1999, and an independent cohort of 275 patients receiving mechanical ventilation were enrolled for validity testing from February 1, 2000, to May 3, 2001. Interrater reliability of the RASS, Glasgow Coma Scale (GCS), and Ramsay Scale (RS); validity of the RASS correlated with reference standard ratings, assessments of content of consciousness, GCS scores, doses of sedatives and analgesics, and bispectral electroencephalography. In 290-paired observations by nurses, results of both the RASS and RS demonstrated excellent interrater reliability (weighted kappa, 0.91 and 0.94, respectively), which were both superior to the GCS (weighted kappa, 0.64; P<.001 for both comparisons). Criterion validity was tested in 411-paired observations in the first 96 patients of the validation cohort, in whom the RASS showed significant differences between levels of consciousness (P<.001 for all) and correctly identified fluctuations within patients over time (P<.001). In addition, 5 methods were used to test the construct validity of the RASS, including correlation with an attention screening examination (r = 0.78, P<.001), GCS scores (r = 0.91, P<.001), quantity of different psychoactive medication dosages 8 hours prior to assessment (eg, lorazepam: r = - 0.31, P<.001), successful extubation (P =.07), and bispectral electroencephalography (r = 0.63, P

  10. "Cross-Cultural Adaptation Of The Multiple Sclerosis Impact Scale (MSIS-29 For Iranian MS Patients, Evaluation Of Reliability And Validity "

    Directory of Open Access Journals (Sweden)

    P. Ayatollahi

    2006-05-01

    Full Text Available Background and Aim: Measuring the outcome of chronic diseases such as multiple sclerosis is an important factor in assessment of disease impact on different dimensions of quality of life and in evaluation of therapeutic interventions. The aim of this study was to perform the cross-cultural adaptation of the MSIS-29 which is a MS-specific outcome measure for Iranian patients. Materials and Methods: The Iranian adaptation process of the MSIS-29 included 5 steps. To evaluate psychometric properties of the translated version, the questionnaire was administered to a consecutive sample of 96 patients with clinically definite MS referred to our out-patient clinic. Test-retest reliability was assessed in a sub-sample consisted of 30 patients. These patients completed the questionnaire on two occasions separated by a 7-day interval. The Iranian version of the SF-36 was also administered to this sub-sample in order to evaluate the validity of translated MSIS-29. Results: Statistical analysis indicated that the Persian version of the MSIS-29 had high internal consistency (cronbach’s alpha coefficients > 0.70 and test-retest reliability (intra-class correlation coefficients >0.70 and a good validity. Conclusion: The Persian version of the MSIS-29 is a reliable and valid instrument for measuring MS outcome in Iranian patients. It can be used in clinical trials and cross-sectional studies.

  11. Comparing cluster-level dynamic treatment regimens using sequential, multiple assignment, randomized trials: Regression estimation and sample size considerations.

    Science.gov (United States)

    NeCamp, Timothy; Kilbourne, Amy; Almirall, Daniel

    2017-08-01

    Cluster-level dynamic treatment regimens can be used to guide sequential treatment decision-making at the cluster level in order to improve outcomes at the individual or patient-level. In a cluster-level dynamic treatment regimen, the treatment is potentially adapted and re-adapted over time based on changes in the cluster that could be impacted by prior intervention, including aggregate measures of the individuals or patients that compose it. Cluster-randomized sequential multiple assignment randomized trials can be used to answer multiple open questions preventing scientists from developing high-quality cluster-level dynamic treatment regimens. In a cluster-randomized sequential multiple assignment randomized trial, sequential randomizations occur at the cluster level and outcomes are observed at the individual level. This manuscript makes two contributions to the design and analysis of cluster-randomized sequential multiple assignment randomized trials. First, a weighted least squares regression approach is proposed for comparing the mean of a patient-level outcome between the cluster-level dynamic treatment regimens embedded in a sequential multiple assignment randomized trial. The regression approach facilitates the use of baseline covariates which is often critical in the analysis of cluster-level trials. Second, sample size calculators are derived for two common cluster-randomized sequential multiple assignment randomized trial designs for use when the primary aim is a between-dynamic treatment regimen comparison of the mean of a continuous patient-level outcome. The methods are motivated by the Adaptive Implementation of Effective Programs Trial which is, to our knowledge, the first-ever cluster-randomized sequential multiple assignment randomized trial in psychiatry.

  12. A note on ranking assignments using reoptimization

    DEFF Research Database (Denmark)

    Pedersen, Christian Roed; Nielsen, L.R.; Andersen, K.A.

    2005-01-01

    We consider the problem of ranking assignments according to cost in the classical linear assignment problem. An algorithm partitioning the set of possible assignments, as suggested by Murty, is presented where, for each partition, the optimal assignment is calculated using a new reoptimization...

  13. Competitive Traffic Assignment in Road Networks

    Directory of Open Access Journals (Sweden)

    Krylatov Alexander Y.

    2016-09-01

    Full Text Available Recently in-vehicle route guidance and information systems are rapidly developing. Such systems are expected to reduce congestion in an urban traffic area. This social benefit is believed to be reached by imposing the route choices on the network users that lead to the system optimum traffic assignment. However, guidance service could be offered by different competitive business companies. Then route choices of different mutually independent groups of users may reject traffic assignment from the system optimum state. In this paper, a game theoretic approach is shown to be very efficient to formalize competitive traffic assignment problem with various groups of users in the form of non-cooperative network game with the Nash equilibrium search. The relationships between the Wardrop’s system optimum associated with the traffic assignment problem and the Nash equilibrium associated with the competitive traffic assignment problem are investigated. Moreover, some related aspects of the Nash equilibrium and the Wardrop’s user equilibrium assignments are also discussed.

  14. Measuring the quality of patient-centered care: why patient-reported measures are critical to reliable assessment

    Directory of Open Access Journals (Sweden)

    Tzelepis F

    2015-06-01

    Full Text Available Flora Tzelepis, Robert W Sanson-Fisher, Alison C Zucca, Elizabeth A FradgleyPriority Research Centre for Health Behaviour, University of Newcastle and Hunter Medical Research Institute, Newcastle, NSW, AustraliaPurpose: The Institute of Medicine (IOM identified patient-centeredness as crucial to quality health care. The IOM endorsed six patient-centeredness dimensions that stipulated that care must be: respectful to patients’ values, preferences, and expressed needs; coordinated and integrated; provide information, communication, and education; ensure physical comfort; provide emotional support; and involve family and friends. Patient-reported measures examine the patient’s perspective and are essential to the accurate assessment of patient-centered care. This article’s objectives are to: 1 use the six IOM-endorsed patient-centeredness dimensions as a framework to outline why patient-reported measures are crucial to the reliable measurement of patient-centered care; and 2 to identify existing patient-reported measures that assess each patient-centered care dimension.Methods: For each IOM-endorsed patient-centeredness dimension, the published literature was searched to highlight the essential role of patients in assessing patient-centered care and informing quality improvement efforts. Existing literature was also searched to identify examples of patient-reported measures that assess each patient-centeredness dimension.Conclusion: Patient-reported measures are arguably the best way to measure patient-centeredness. For instance, patients are best positioned to determine whether care aligns with patient values, preferences, and needs and the Measure of Patient Preferences is an example of a patient-reported measure that does so. Furthermore, only the patient knows whether they received the level of information desired, and if information was understood and can be recalled. Patient-reported measures that examine information provision include

  15. Concurrent validity and interrater reliability of a new smartphone application to assess 3D active cervical range of motion in patients with neck pain.

    Science.gov (United States)

    Stenneberg, Martijn S; Busstra, Harm; Eskes, Michel; van Trijffel, Emiel; Cattrysse, Erik; Scholten-Peeters, Gwendolijne G M; de Bie, Rob A

    2018-04-01

    There is a lack of valid, reliable, and feasible instruments for measuring planar active cervical range of motion (aCROM) and associated 3D coupling motions in patients with neck pain. Smartphones have advanced sensors and appear to be suitable for these measurements. To estimate the concurrent validity and interrater reliability of a new iPhone application for assessing planar aCROM and associated 3D coupling motions in patients with neck pain, using an electromagnetic tracking device as a reference test. Cross-sectional study. Two samples of neck pain patients were recruited; 30 patients for the validity study and 26 patients for the reliability study. Validity was estimated using intraclass correlation coefficients (ICCs), and by calculating 95% limits of agreement (LoA). To estimate interrater reliability, ICCs were calculated. Cervical 3D coupling motions were analyzed by calculating the cross-correlation coefficients and ratio between the main motions and coupled motions for both instruments. ICCs for concurrent validity and interrater reliability ranged from 0.90 to 0.99. The width of the 95% LoA ranged from about 5° for right lateral bending to 11° for total rotation. No significant differences were found between both devices for associated coupling motion analysis. The iPhone application appears to be a useful discriminative tool for the measurement of planar aCROM and associated coupling motions in patients with neck pain. It fulfills the need for a valid, reliable, and feasible instrument in clinical practice and research. Therapists and researchers should consider measurement error when interpreting scores. Copyright © 2017 Elsevier Ltd. All rights reserved.

  16. Reliability and validity enhancement: a treatment package for increasing fidelity of self-report.

    Science.gov (United States)

    Bornstein, P H; Hamilton, S B; Miller, R K; Quevillon, R P; Spitzform, M

    1977-07-01

    This study investigated the effects of reliability and validity "enhancers" on fidelity of self-report data in an analogue therapy situation. Under the guise of a Concentration Skills Training Program, 57 Ss were assigned randomly to one of the following conditions: (a) Reliability Enhancement; (b) Truth Talk; (c) No Comment Control. Results indicated significant differences among groups (p less than .05). In addition, tests of multiple comparisons revealed that Reliability Enhancement was significantly different from Truth Talk in occurrences of unreliability (p less than .05). These findings are discussed in light of the increased reliance on self-report data in behavioral intervention, and recommendations are made for future research.

  17. Unexpected ethical dilemmas in sex assignment in 46,XY DSD due to 5-alpha reductase type 2 deficiency.

    Science.gov (United States)

    Byers, Heather M; Mohnach, Lauren H; Fechner, Patricia Y; Chen, Ming; Thomas, Inas H; Ramsdell, Linda A; Shnorhavorian, Margarett; McCauley, Elizabeth A; Amies Oelschlager, Anne-Marie E; Park, John M; Sandberg, David E; Adam, Margaret P; Keegan, Catherine E

    2017-06-01

    Sex assignment at birth remains one of the most clinically challenging and controversial topics in 46,XY disorders of sexual development (DSD). This is particularly challenging in deficiency of 5-alpha reductase type 2 given that external genitalia are typically undervirilized at birth but typically virilize at puberty to a variable degree. Historically, most individuals with 5-alpha reductase deficiency were raised females. However, reports that over half of patients who underwent a virilizing puberty adopted an adult male gender identity have challenged this practice. Consensus guidelines on assignment of sex of rearing at birth are equivocal or favor male assignment in the most virilized cases. While a male sex of rearing assignment may avoid lifelong hormonal therapy and/or allow the potential for fertility, female sex assignment may be more consistent with external anatomy in the most severely undervirilized cases. Herein, we describe five patients with 46,XY DSD due 5-alpha-reductase type 2 deficiency, all with a severe phenotype. An inter-disciplinary DSD medical team at one of two academic centers evaluated each patient. This case series illustrates the complicated decision-making process of assignment of sex of rearing at birth in 5-alpha reductase type 2 deficiency and the challenges that arise when the interests of the child, parental wishes, recommendations of the medical team, and state law collide. © 2017 Wiley Periodicals, Inc.

  18. Real life working shift assignment problem

    Science.gov (United States)

    Sze, San-Nah; Kwek, Yeek-Ling; Tiong, Wei-King; Chiew, Kang-Leng

    2017-07-01

    This study concerns about the working shift assignment in an outlet of Supermarket X in Eastern Mall, Kuching. The working shift assignment needs to be solved at least once in every month. Current approval process of working shifts is too troublesome and time-consuming. Furthermore, the management staff cannot have an overview of manpower and working shift schedule. Thus, the aim of this study is to develop working shift assignment simulation and propose a working shift assignment solution. The main objective for this study is to fulfill manpower demand at minimum operation cost. Besides, the day off and meal break policy should be fulfilled accordingly. Demand based heuristic is proposed to assign working shift and the quality of the solution is evaluated by using the real data.

  19. Association of the position of a hospital-acquired condition diagnosis code with changes in medicare severity diagnosis-related group assignment.

    Science.gov (United States)

    Johnson, Tricia; Kane, Jason M; Odwazny, Richard; McNutt, Robert

    2014-11-01

    Incentives to improve quality include paying less for adverse events, including the Centers for Medicare and Medicaid Services' policy to not pay additionally for events classified as hospital-acquired conditions (HACs). This policy is controversial, as variable coding practices at hospitals may lead to differences in the inclusion and position of HACs in the list of codes used for Medicare Severity Diagnosis-Related Group (MS-DRG) assignment. Evaluate changes in MS-DRG assignment for patients with an HAC and test the association of the position of an HAC in the list of International Classification of Diseases, 9th Revision (ICD-9) diagnosis codes with change in MS-DRG assignment. Retrospective analysis of patients discharged from hospital members of the University HealthSystem Consortium's Clinical Data Base between October 2007 and April 2008. Comparisons were made between the MS-DRG assigned when the HAC was not included in the list of ICD-9 diagnosis codes and the MS-DRG that would have been assigned had the HAC code been included in the assignment. Of the 7027 patients with an HAC, 13.8% changed MS-DRG assignment when the HAC was removed. An HAC in the second position versus third position or lower was associated with a 40-fold increase in the likelihood of MS-DRG change. The position of an HAC in the list of diagnosis codes, rather than the presence of an HAC, is associated with a change in MS-DRG assignment. HACs have little effect on reimbursement unless the HAC is in the second position and patients have minor severity of illness. © 2014 Society of Hospital Medicine.

  20. Resolution of GSI B-56 - Emergency diesel generator reliability

    International Nuclear Information System (INIS)

    Serkiz, A.W.

    1989-01-01

    The need for an emergency diesel generator (EDG) reliability program has been established by 10 CFR Part 50, Section 50.63, Loss of All Alternating Current Power, which requires that licensees assess their station blackout coping and recovery capability. EDGs are the principal emergency ac power sources for avoiding a station blackout. Regulatory Guide 1.155, Station Blackout, identifies a need for (1) a nuclear unit EDG reliability level of at least 0.95, and (2) an EDG reliability program to monitor and maintain the required EDG reliability levels. NUMARC-8700, Guidelines and Technical Bases for NUMARC Initiatives Addressing Station Blackout at Light Water Reactors, also provides guidance on such needs. The resolution of GSI B-56, Diesel Reliability will be accomplished by issuing Regulatory Guide 1.9, Rev. 3, Selection, Design, Qualification, Testing, and Reliability of Diesel Generator Units Used as Onsite Electric Power Systems at Nuclear Plants. This revision will integrate into a single regulatory guide pertinent guidance previously addressed in R.G. 1.9, Rev. 2, R.G. 1.108, and Generic Letter 84-15. R.G. 1.9 has been expanded to define the principal elements of an EDG reliability program for monitoring and maintaining EDG reliability levels selected for SBO. In addition, alert levels and corrective actions have been defined to detect a deteriorating situation for all EDGs assigned to a particular nuclear unit, as well as an individual problem EDG

  1. 24 CFR 221.770 - Assignment option.

    Science.gov (United States)

    2010-04-01

    ... 24 Housing and Urban Development 2 2010-04-01 2010-04-01 false Assignment option. 221.770 Section... § 221.770 Assignment option. A mortgagee holding a conditional or firm commitment issued on or before... mortgagee's approved underwriter on or before November 30, 1983) has the option to assign, transfer and...

  2. Optimally Fortifying Logic Reliability through Criticality Ranking

    Directory of Open Access Journals (Sweden)

    Yu Bai

    2015-02-01

    Full Text Available With CMOS technology aggressively scaling towards the 22-nm node, modern FPGA devices face tremendous aging-induced reliability challenges due to bias temperature instability (BTI and hot carrier injection (HCI. This paper presents a novel anti-aging technique at the logic level that is both scalable and applicable for VLSI digital circuits implemented with FPGA devices. The key idea is to prolong the lifetime of FPGA-mapped designs by strategically elevating the VDD values of some LUTs based on their modular criticality values. Although the idea of scaling VDD in order to improve either energy efficiency or circuit reliability has been explored extensively, our study distinguishes itself by approaching this challenge through an analytical procedure, therefore being able to maximize the overall reliability of the target FPGA design by rigorously modeling the BTI-induced device reliability and optimally solving the VDD assignment problem. Specifically, we first develop a systematic framework to analytically model the reliability of an FPGA LUT (look-up table, which consists of both RAM memory bits and associated switching circuit. We also, for the first time, establish the relationship between signal transition density and a LUT’s reliability in an analytical way. This key observation further motivates us to define the modular criticality as the product of signal transition density and the logic observability of each LUT. Finally, we analytically prove, for the first time, that the optimal way to improve the overall reliability of a whole FPGA device is to fortify individual LUTs according to their modular criticality. To the best of our knowledge, this work is the first to draw such a conclusion.

  3. [Reliability and validity of the Severe Impairment Battery, short form (SIB-s), in patients with dementia in Spain].

    Science.gov (United States)

    Cruz-Orduña, Isabel; Agüera-Ortiz, Luis F; Montorio-Cerrato, Ignacio; León-Salas, Beatriz; Valle de Juan, M Cristina; Martínez-Martín, Pablo

    2015-01-01

    People with progressive dementia evolve into a state where traditional neuropsychological tests are not effective. Severe Impairment Battery (SIB) and short form (SIB-s) were developed for evaluating the cognitive status in patients with severe dementia. To evaluate the psychometric attributes of the SIB-s in patients with severe dementia. 127 institutionalized patients (female: 86.6%; mean age: 82.6 ± 7.5 years-old) with dementia were assessed with the SIB-s, the Global Deterioration Scale (GDS), Mini-Mental State Examination (MMSE), Severe Mini-Mental State Examination (sMMSE), Barthel Index and FAST. SIB-s acceptability, reliability, validity and precision were analyzed. The mean total score for scale was 19.1 ± 15.34 (range: 0-48). Floor effect was 18.1%, only marginally higher than the desirable 15%. Factor analysis identified a single factor explaining 68% of the total variance of the scale. Cronbach's alpha coefficient was 0.96 and the item-total corrected correlation ranged from 0.27 to 0.83. The item homogeneity value was 0.43. Test-retest and inter-rater reliability for the total score was satisfactory (ICC: 0.96 and 0.95, respectively). The SIB-s showed moderate correlation with functional dependency scales (Barthel Index: 0.48, FAST: -0.74). Standard error of measurement was 3.07 for the total score. The SIB-s is a reliable and valid instrument for evaluating patients with severe dementia in the Spanish population of relatively brief instruments.

  4. Reliability of movement control tests in the lumbar spine

    Directory of Open Access Journals (Sweden)

    de Bruin Eling D

    2007-09-01

    Full Text Available Abstract Background Movement control dysfunction [MCD] reduces active control of movements. Patients with MCD might form an important subgroup among patients with non specific low back pain. The diagnosis is based on the observation of active movements. Although widely used clinically, only a few studies have been performed to determine the test reliability. The aim of this study was to determine the inter- and intra-observer reliability of movement control dysfunction tests of the lumbar spine. Methods We videoed patients performing a standardized test battery consisting of 10 active movement tests for motor control in 27 patients with non specific low back pain and 13 patients with other diagnoses but without back pain. Four physiotherapists independently rated test performances as correct or incorrect per observation, blinded to all other patient information and to each other. The study was conducted in a private physiotherapy outpatient practice in Reinach, Switzerland. Kappa coefficients, percentage agreements and confidence intervals for inter- and intra-rater results were calculated. Results The kappa values for inter-tester reliability ranged between 0.24 – 0.71. Six tests out of ten showed a substantial reliability [k > 0.6]. Intra-tester reliability was between 0.51 – 0.96, all tests but one showed substantial reliability [k > 0.6]. Conclusion Physiotherapists were able to reliably rate most of the tests in this series of motor control tasks as being performed correctly or not, by viewing films of patients with and without back pain performing the task.

  5. Qualitative soil moisture assessment in semi-arid Africa - the role of experience and training on inter-rater reliability

    Science.gov (United States)

    Rinderer, M.; Komakech, H. C.; Müller, D.; Wiesenberg, G. L. B.; Seibert, J.

    2015-08-01

    Soil and water management is particularly relevant in semi-arid regions to enhance agricultural productivity. During periods of water scarcity, soil moisture differences are important indicators of the soil water deficit and are traditionally used for allocating water resources among farmers of a village community. Here we present a simple, inexpensive soil wetness classification scheme based on qualitative indicators which one can see or touch on the soil surface. It incorporates the local farmers' knowledge on the best soil moisture conditions for seeding and brick making in the semi-arid environment of the study site near Arusha, Tanzania. The scheme was tested twice in 2014 with farmers, students and experts (April: 40 persons, June: 25 persons) for inter-rater reliability, bias of individuals and functional relation between qualitative and quantitative soil moisture values. During the test in April farmers assigned the same wetness class in 46 % of all cases, while students and experts agreed on about 60 % of all cases. Students who had been trained in how to apply the method gained higher inter-rater reliability than their colleagues with only a basic introduction. When repeating the test in June, participants were given improved instructions, organized in small subgroups, which resulted in a higher inter-rater reliability among farmers. In 66 % of all classifications, farmers assigned the same wetness class and the spread of class assignments was smaller. This study demonstrates that a wetness classification scheme based on qualitative indicators is a robust tool and can be applied successfully regardless of experience in crop growing and education level when an in-depth introduction and training is provided. The use of a simple and clear layout of the assessment form is important for reliable wetness class assignments.

  6. Qualitative soil moisture assessment in semi-arid Africa: the role of experience and training on inter-rater reliability

    Science.gov (United States)

    Rinderer, M.; Komakech, H.; Müller, D.; Seibert, J.

    2015-03-01

    Soil and water management is particularly relevant in semi-arid regions to enhance agricultural productivity. During periods of water scarcity soil moisture differences are important indicators of the soil water deficit and are traditionally used for allocating water resources among farmers of a village community. Here we present a simple, inexpensive soil wetness classification scheme based on qualitative indicators which one can see or touch on the soil surface. It incorporates the local farmers' knowledge on the best soil moisture conditions for seeding and brick making in the semi-arid environment of the study site near Arusha, Tanzania. The scheme was tested twice in 2014 with farmers, students and experts (April: 40 persons, June: 25 persons) for inter-rater reliability, bias of individuals and functional relation between qualitative and quantitative soil moisture values. During the test in April farmers assigned the same wetness class in 46% of all cases while students and experts agreed in about 60% of all cases. Students who had been trained in how to apply the method gained higher inter-rater reliability than their colleagues with only a basic introduction. When repeating the test in June, participants were given improved instructions, organized in small sub-groups, which resulted in a higher inter-rater reliability among farmers. In 66% of all classifications farmers assigned the same wetness class and the spread of class assignments was smaller. This study demonstrates that a wetness classification scheme based on qualitative indicators is a robust tool and can be applied successfully regardless of experience in crop growing and education level when an in-depth introduction and training is provided. The use of a simple and clear layout of the assessment form is important for reliable wetness class assignments.

  7. Job Assignments under Moral Hazard

    DEFF Research Database (Denmark)

    Koch, Alexander; Nafziger, Julia

    Inefficient job assignments are usually explained with incomplete information about employees' abilities or contractual imperfections. We show that inefficient assignments arise even without uncertainty about the employee's ability and with complete contracts. Building on this result we provide...

  8. 24 CFR 221.255 - Assignment option.

    Science.gov (United States)

    2010-04-01

    ... 24 Housing and Urban Development 2 2010-04-01 2010-04-01 false Assignment option. 221.255 Section... Assignment option. (a) A mortgagee holding a mortgage insured pursuant to a conditional or firm commitment issued on or before November 30, 1983 has the option to assign, transfer and deliver to the Commissioner...

  9. The reliability of repeated TMS measures in older adults and in patients with subacute and chronic stroke

    Directory of Open Access Journals (Sweden)

    Heidi M. Schambra

    2015-09-01

    Full Text Available The reliability of transcranial magnetic stimulation (TMS measures in healthy older adults and stroke patients has been insufficiently characterized. We determined whether common TMS measures could reliably evaluate change in individuals and in groups using the smallest detectable change (SDC, or could tell subjects apart using the intraclass correlation coefficient (ICC. We used a single-rater test-retest design in older healthy, subacute stroke, and chronic stroke subjects. At twice daily sessions on two consecutive days, we recorded resting motor threshold, test stimulus intensity, recruitment curves, short-interval intracortical inhibition and facilitation, and long-interval intracortical inhibition. Using variances estimated from a random effects model, we calculated the SDC and ICC for each TMS measure. For all TMS measures in all groups, SDCs for single subjects were large; only with modest group sizes did the SDCs become low. Thus, while these TMS measures cannot be reliably used as a biomarker to detect individual change, they can reliably detect change exceeding measurement noise in moderate-sized groups. For several of the TMS measures, ICCs were universally high, suggesting that they can reliably discriminate between subjects. Though most TMS measures have sufficient reliability in particular contexts, work establishing their validity, responsiveness, and clinical relevance is still needed.

  10. Reliability and validity of a low load endurance strength test for upper and lower extremities in patients with fibromyalgia.

    Science.gov (United States)

    Munguía-Izquierdo, Diego; Legaz-Arrese, Alejandro

    2012-11-01

    To evaluate the reliability, standard error of the mean (SEM), clinical significant change, and known group validity of 2 assessments of endurance strength to low loads in patients with fibromyalgia syndrome (FS). Cross-sectional reliability and comparative study. University Pablo de Olavide, Seville, Spain. Middle-aged women with FS (n=95) and healthy women (n=64) matched for age, weight, and body mass index (BMI) were recruited for the study. Not applicable. The endurance strength to low loads tests of the upper and lower extremities and anthropometric measures (BMI) were used for the evaluations. The differences between the readings (tests 1 and 2) and the SDs of the differences, intraclass correlation coefficient (ICC) model (2,1), 95% confidence interval for the ICC, coefficient of repeatability, intrapatient SD, SEM, Wilcoxon signed-rank test, and Bland-Altman plots were used to examine reliability. A Mann-Whitney U test was used to analyze the differences in test values between the patient group and the control group. We hypothesized that patients with FS would have an endurance strength to low loads performance in lower and upper extremities at least twice as low as that of the healthy controls. Satisfactory test-retest reliability and SEMs were found for the lower extremity, dominant arm, and nondominant arm tests (ICC=.973-.979; P.05 for all). The Bland-Altman plots showed 95% limits of agreement for the lower extremity (4.7 to -4.5), dominant arm (3.8 to -4.4), and nondominant arm (3.9 to -4.1) tests. The endurance strength to low loads test scores for the patients with FS were 4-fold lower than for the controls in all performed tests (P<.001 for all). The endurance strength to low loads tests showed good reliability and known group validity and can be recommended for evaluating endurance strength to low loads in patients with FS. For individual evaluation, however, an improved score of at least 4 and 5 repetitions for the upper and lower extremities

  11. An algorithm for ranking assignments using reoptimization

    DEFF Research Database (Denmark)

    Pedersen, Christian Roed; Nielsen, Lars Relund; Andersen, Kim Allan

    2008-01-01

    We consider the problem of ranking assignments according to cost in the classical linear assignment problem. An algorithm partitioning the set of possible assignments, as suggested by Murty, is presented where, for each partition, the optimal assignment is calculated using a new reoptimization...... technique. Computational results for the new algorithm are presented...

  12. 48 CFR 42.602 - Assignment and location.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 1 2010-10-01 2010-10-01 false Assignment and location... Assignment and location. (a) A CACO may be assigned only when (1) the contractor has at least two locations..., or a full-time CACO may be assigned. In determining the location of the CACO, the responsible agency...

  13. [Reliability and validity of the Chinese version on Comprehensive Scores for Financial Toxicity based on the patient-reported outcome measures].

    Science.gov (United States)

    Yu, H H; Bi, X; Liu, Y Y

    2017-08-10

    Objective: To evaluate the reliability and validity of the Chinese version on comprehensive scores for financial toxicity (COST), based on the patient-reported outcome measures. Methods: A total of 118 cancer patients were face-to-face interviewed by well-trained investigators. Cronbach's α and Pearson correlation coefficient were used to evaluate reliability. Content validity index (CVI) and exploratory factor analysis (EFA) were used to evaluate the content validity and construct validity, respectively. Results: The Cronbach's α coefficient appeared as 0.889 for the whole questionnaire, with the results of test-retest were between 0.77 and 0.98. Scale-content validity index (S-CVI) appeared as 0.82, with item-content validity index (I-CVI) between 0.83 and 1.00. Two components were extracted from the Exploratory factor analysis, with cumulative rate as 68.04% and loading>0.60 on every item. Conclusion: The Chinese version of COST scale showed high reliability and good validity, thus can be applied to assess the financial situation in cancer patients.

  14. Lifestyle changes of Japanese people on overseas assignment in Michigan, USA

    Directory of Open Access Journals (Sweden)

    Kitamura Kazuya

    2009-07-01

    Full Text Available Abstract Background Temporary work assignments in the United States (US are widely considered to have negative health outcomes on Asians mostly due to adverse changes in diet and exercise, though there is little research on this phenomenon. This study investigated the impact of lifestyle changes on the biological and psychological health and health behaviours of Japanese people on temporary assignments in the US. Methods In this cross sectional survey, we distributed a 38 item self-administered questionnaire addressing health habits, mental health function, lifestyle changes and dietary habits to adult Japanese patients presenting for general physicals at a family medicine clinic serving Japanese patients. We conducted simple statistics and regression analysis between length of stay and other health outcomes to determine whether length of residence in the US was predictive of negative lifestyle changes. Results Most participants reported increased caloric intake, weight gain, and less exercise. They also reported increased time with family. More women than men reported physical symptoms and anxiety related to stress. Smoking and alcohol intake were essentially unchanged. No associations were identified between length of residence in the US and health lifestyle habits or other health outcomes. Conclusion Negative lifestyle changes occur in diet and exercise for overseas Japanese people, but a positive change in increased family time was found. Women appear to be at a greater risk for somatic disorders than men. As duration of stay does not appear predictive of adverse changes, clinicians should advise patients going abroad of these risks regardless of the term of the work assignment.

  15. Reliability and validity of CODA motion analysis system for measuring cervical range of motion in patients with cervical spondylosis and anterior cervical fusion.

    Science.gov (United States)

    Gao, Zhongyang; Song, Hui; Ren, Fenggang; Li, Yuhuan; Wang, Dong; He, Xijing

    2017-12-01

    The aim of the present study was to evaluate the reliability of the Cartesian Optoelectronic Dynamic Anthropometer (CODA) motion system in measuring the cervical range of motion (ROM) and verify the construct validity of the CODA motion system. A total of 26 patients with cervical spondylosis and 22 patients with anterior cervical fusion were enrolled and the CODA motion analysis system was used to measure the three-dimensional cervical ROM. Intra- and inter-rater reliability was assessed by interclass correlation coefficients (ICCs), standard error of measurement (SEm), Limits of Agreements (LOA) and minimal detectable change (MDC). Independent samples t-tests were performed to examine the differences of cervical ROM between cervical spondylosis and anterior cervical fusion patients. The results revealed that in the cervical spondylosis group, the reliability was almost perfect (intra-rater reliability: ICC, 0.87-0.95; LOA, -12.86-13.70; SEm, 2.97-4.58; inter-rater reliability: ICC, 0.84-0.95; LOA, -13.09-13.48; SEm, 3.13-4.32). In the anterior cervical fusion group, the reliability was high (intra-rater reliability: ICC, 0.88-0.97; LOA, -10.65-11.08; SEm, 2.10-3.77; inter-rater reliability: ICC, 0.86-0.96; LOA, -10.91-13.66; SEm, 2.20-4.45). The cervical ROM in the cervical spondylosis group was significantly higher than that in the anterior cervical fusion group in all directions except for left rotation. In conclusion, the CODA motion analysis system is highly reliable in measuring cervical ROM and the construct validity was verified, as the system was sufficiently sensitive to distinguish between the cervical spondylosis and anterior cervical fusion groups based on their ROM.

  16. Cross-cultural adaptation, reliability, and validity of the Turkish version of the Cancer Fatigue Scale in patients with breast cancer

    Science.gov (United States)

    Şahin, Sedef; Huri, Meral; Aran, Orkun Tahir; Uyanık, Mine

    2018-02-23

    Background/aim: The Cancer Fatigue Scale (CFS) was developed to evaluate the severity of fatigue in patients with breast cancer. The aim of this study is to translate and culturally adapt a Turkish version and investigate the validity and reliability of the CFS in Turkish patients with fatigue symptoms. Materials and methods: Eighty participants completed the Turkish version of the CFS for breast cancer and the European Organization for Research and Treatment of Cancer Quality of Life Core Questionnaire ″Core 30″ (EORTC QLQ-C30). Test-retest reliability was evaluated by repeating the CFS with a 7-day interval. Results: The CFS demonstrated high test-retest reliability (ICC = 0.95) and good internal consistency (Cronbach′s alpha = 0.74) for all domains. The Kaiser-Meyer-Olkin measure of sampling adequacy was found to be 0.819, which is considered to be satisfactory (>0.5). Correlations between domains of CFS physical and EORTC physical (r: 0.77), CFS cognitive and EORTC cognitive (r: 0.70), and CFS physical and EORTC fatigue (r: 0.80) were found to be significant. Conclusion: The Turkish version of the CFS is a reliable and valid instrument to assess physical, effective, and cognitive dimensions of fatigue. The CFS may be used to evaluate the severity of fatigue in Turkish-speaking breast cancer patients.

  17. Intra- and inter-rater reliability of movement and palpation tests in patients with neck pain: A systematic review.

    Science.gov (United States)

    Jonsson, Anders; Rasmussen-Barr, Eva

    2018-03-01

    Neck pain is common and often becomes chronic. Various clinical tests of the cervical spine are used to direct and evaluate treatment. This systematic review aimed to identify studies examining the intra- and/or interrater reliability of tests used in clinical examination of patients with neck pain. A database search up to April 2016 was conducted in PubMed, CINAHL, and AMED. The Quality Appraisal of Reliability Studies Checklist (QAREL) was used to assess risk of bias. Eleven studies were included, comprising tests of active and passive movement and pain evaluating participants with ongoing neck pain. One study was assessed with a low risk of bias, three with medium risk, while the rest were assessed with high risk of bias. The results showed differing reliabilities for the included tests ranging from poor to almost perfect. In conclusion, active movement and pain for pain or mobility overall presented acceptable to very good reliability (Kappa >0.40); while passive intervertebral tests had lower Kappa values, suggesting poor reliability. It may be a coincidence that the studies indicating very good reliability tended to be of higher quality (low to moderate risk of bias), while studies finding poor reliability tended to be of lower quality (high risk of bias). Regardless, the current recommendation from this review would suggest the clinical use of tests with acceptable reliability and avoiding the use of tests that have been shown to not be reliable. Finally, it is critical that all future reliability studies are of higher quality with low risk of bias.

  18. Reliability and Validity of Beliefs about Substance Use (BSU Questionnaire in Alcohol Dependent Patients.

    Directory of Open Access Journals (Sweden)

    Selçuk ASLAN

    2012-11-01

    Full Text Available Objective: In this study, it is aimed to evaluate the validity and reliability of the Beliefs About Substance Use Questionnaire (BSU which was originally developed by Wright (1993. Method: Seventy alcohol addicted inpatients, who were admitted to Ankara Dışkapı Yıldırım Beyazıt Education and Research Hospital Psychiatry Clinic, 31 healthy volunteers who had never used alcohol and 33 social drinkers were evaluated. For all groups, BSU and Craving Beliefs Questionnaire (CBQ, for the patient groups, Beck Anxiety Inventory (BAI, Clinical Institute Withdrawal Assessment (CIWA, Dysfunctional Attitudes Questionnaire (DAS and Automatic Thoughts Questionnaire (ATQ were used as the assessment tools. The correlations and differences between the questionnaires were studied. Results: Mean age of the addicted patients, healthy controls and social drinkers were 42,3± 7,0, 33,5± 9,9 and 33,2± 8,9, respectively. In patient group, mean BSU score was 46,4 ± 21,2. For alcohol addicts, internal reliability of BSU was found to be adequate (Cronbach alfa=0.91 and item-total score correlations were between 0.33 and 0.69. Basic component analysis showed one basic factor. A positive correlation has been found between BSU and CBQ, and ATQ scores. No correlations have been found between total and subscale scores of DAS and total scores of CIWA, BAI and BSU. In evaluation of validity, BSU mean scores of alcohol addicts were found to be significantly higher than healthy controls and social drinkers. Conclusion: Our findings support that Turkish version of BSU is an adequate tool that can be used to evaluate alcohol addicted patients` cognitive believes about alcohol use

  19. Reliability of joint count assessment in rheumatoid arthritis: a systematic literature review.

    Science.gov (United States)

    Cheung, Peter P; Gossec, Laure; Mak, Anselm; March, Lyn

    2014-06-01

    Joint counts are central to the assessment of rheumatoid arthritis (RA) but reliability is an issue. To evaluate the reliability and agreement of joint counts (intra-observer and inter-observer) by health care professionals (physicians, nurses, and metrologists) and patients in RA, and the impact of training and standardization on joint count reliability through a systematic literature review. Articles reporting joint count reliability or agreement in RA in PubMed, EMBase, and the Cochrane library between 1960 and 2012 were selected. Data were extracted regarding tender joint counts (TJCs) and swollen joint counts (SJCs) derived by physicians, metrologists, or patients for intra-observer and inter-observer reliability. In addition, methods and effects of training or standardization were extracted. Statistics expressing reliability such as intraclass correlation coefficients (ICCs) were extracted. Data analysis was primarily descriptive due to high heterogeneity. Twenty-eight studies on health care professionals (HCP) and 20 studies on patients were included. Intra-observer reliability for TJCs and SJCs was good for HCPs and patients (range of ICC: 0.49-0.98). Inter-observer reliability between HCPs for TJCs was higher than for SJCs (range of ICC: 0.64-0.88 vs. 0.29-0.98). Patient inter-observer reliability with HCPs as comparators was better for TJCs (range of ICC: 0.31-0.91) compared to SJCs (0.16-0.64). Nine studies (7 with HCPs and 2 with patients) evaluated consensus or training, with improvement in reliability of TJCs but conflicting evidence for SJCs. Intra- and inter-observer reliability was high for TJCs for HCPs and patients: among all groups, reliability was better for TJCs than SJCs. Inter-observer reliability of SJCs was poorer for patients than HCPs. Data were inconclusive regarding the potential for training to improve SJC reliability. Overall, the results support further evaluation for patient-reported joint counts as an outcome measure. © 2013

  20. Test-retest reliability and construct validity of the Helplessness, Hopelessness, and Haplessness Scale in patients with anxiety disorders.

    Science.gov (United States)

    Vatan, Sevginar; Ertaş, Sedar; Lester, David

    2011-04-01

    In a sample of 100 Turkish psychiatric patients with diagnoses of anxiety disorders, Lester's Helplessness, Hopelessness, and Haplessness inventory had moderate estimates of internal consistency, test-retest reliability, and construct validity.

  1. Test-Retest Reliability of Handgrip Strength as an Outcome Measure in Patients With Symptoms of Shoulder Impingement Syndrome.

    Science.gov (United States)

    Savva, Christos; Mougiaris, Paraskevas; Xadjimichael, Christoforos; Karagiannis, Christos; Efstathiou, Michalis

    The purpose of this study was to investigate the degree of test-retest reliability of grip strength measurement using a hand dynamometer in patients with shoulder impingement syndrome. A total of 19 patients (10 women and 9 men; mean ± standard deviation age, 33.2 ± 12.9 years; range 18-59 years) with shoulder impingement syndrome were measured using a hand dynamometer by the same data collector in 2 different testing sessions with a 7-day interval. During each session, patients were encouraged to exert 3 maximal isometric contractions on the affected hand and the mean value of the 3 efforts (measured in kilogram-force [Kgf]) was used for data analysis. The intraclass correlation coefficient (ICC 2,1 ) as well as the standard error of measurement (SEM) and Bland-Altman plot were used to estimate the degree of test-retest reliability and the measurement error, respectively. Grip strength data analysis revealed an ICC 2,1 score of 0.94, which, based on the Shrout classification, is considered as excellent test-retest reliability of grip strength measurement. The small values of SEMs reported in both sessions (SEM 1 , 2.55 Kgf; SEM 2 , 2.39 Kgf) and the small width of the 95% limits of agreement in the Bland-Altman plot (ranging from -7.39 Kgf to 7.03 Kgf) reflected the measurement precision and the narrow variation of the differences during the 2 testing sessions. Results from this study identified excellent test-retest reliability of grip strength measurement in shoulder impingement syndrome, indicating its potential use as an outcome measure in clinical practice. Copyright © 2018. Published by Elsevier Inc.

  2. Preliminary findings on the reliability and validity of the Cantonese Birmingham Cognitive Screen in patients with acute ischemic stroke

    Directory of Open Access Journals (Sweden)

    Pan X

    2015-09-01

    Full Text Available Xiaoping Pan,1,* Haobo Chen,1,2,* Wai-Ling Bickerton,2 Johnny King Lam Lau,2 Anthony Pak Hin Kong,3 Pia Rotshtein,2 Aihua Guo,1 Jianxi Hu,1 Glyn W Humphreys4 1Department of Neurology, Guangzhou First People’s Hospital, Guangzhou Medical University, Guangzhou, People’s Republic of China; 2School of Psychology, University of Birmingham, Birmingham, UK; 3Department of Communication Sciences and Disorders, University of Central Florida, Orlando, FL, USA; 4Department of Experimental Psychology, University of Oxford, Oxford, UK *These authors contributed equally to this work Background: There are no currently effective cognitive assessment tools for patients who have suffered stroke in the People’s Republic of China. The Birmingham Cognitive Screen (BCoS has been shown to be a promising tool for revealing patients’ poststroke cognitive deficits in specific domains, which facilitates more individually designed rehabilitation in the long run. Hence we examined the reliability and validity of a Cantonese version BCoS in patients with acute ischemic stroke, in Guangzhou.Method: A total of 98 patients with acute ischemic stroke were assessed with the Cantonese version of the BCoS, and an additional 133 healthy individuals were recruited as controls. Apart from the BCoS, the patients also completed a number of external cognitive tests, including the Montreal Cognitive Assessment Test (MoCA, Mini Mental State Examination (MMSE, Albert’s cancellation test, the Rey–Osterrieth Complex Figure Test, and six gesture matching tasks. Cutoff scores for failing each subtest, ie, deficits, were computed based on the performance of the controls. The validity and reliability of the Cantonese BCoS were examined, as well as interrater and test–retest reliability. We also compared the proportions of cases being classified as deficits in controlled attention, memory, character writing, and praxis, between patients with and without spoken language impairment

  3. Batch metadata assignment to archival photograph collections using facial recognition software

    Directory of Open Access Journals (Sweden)

    Kyle Banerjee

    2013-07-01

    Full Text Available Useful metadata is essential to giving individual meaning and value within the context of a greater image collection as well as making them more discoverable. However, often little information is available about the photos themselves, so adding consistent metadata to large collections of digital and digitized photographs is a time consuming process requiring highly experienced staff. By using facial recognition software, staff can identify individuals more quickly and reliably. Knowledge of individuals in photos helps staff determine when and where photos are taken and also improves understanding of the subject matter. This article demonstrates simple techniques for using facial recognition software and command line tools to assign, modify, and read metadata for large archival photograph collections.

  4. Validity and reliability of the Spanish version of the 10-item CD-RISC in patients with fibromyalgia

    Science.gov (United States)

    2014-01-01

    Background No resilience scale has been validated in Spanish patients with fibromyalgia. The aim of this study was to evaluate the validity and reliability of the 10-item CD-RISC in a sample of Spanish patients with fibromyalgia. Methods Design: Observational prospective multicenter study. Sample: Patients with diagnoses of fibromyalgia recruited from primary care settings (N = 208). Instruments: In addition to sociodemographic data, the following questionnaires were administered: Pain Visual Analogue Scale (PVAS), the 10-item Connor-Davidson Resilience scale (10-item CD-RISC), the Fibromyalgia Impact Questionnaire (FIQ), the Hospital Anxiety and Depression Scale (HADS), the Pain Catastrophizing Scale (PCS), the Chronic Pain Acceptance Questionnaire (CPAQ), and the Mindful Attention Awareness Scale (MAAS). Results Regarding construct validity, the factor solution in the Principal Component Analysis (PCA) was considered adequate, so the KMO test had a value of 0.91, and the Barlett’s test of sphericity was significant (χ2 = 852.8; gl = 45; p fibromyalgia, acceptable psychometric properties, with a high level of reliability and validity. PMID:24484847

  5. Work assignments, delegation of tasks and job satisfaction among Danish dental hygienists.

    Science.gov (United States)

    Hach, M; Aaberg, K B; Lempert, S M; Danielsen, B

    2017-08-01

    Recent legislation in Denmark has made it possible for dentists to delegate their tasks to dental hygienists. Previous studies have shown that Danish dental hygienists primarily were performing assignments within their own work field. These assignments include prophylaxis or instructing patients in oral health care. However, studies have also shown that Danish dental hygienists performed dental nurse assignments such as chair-side assistance, unit cleaning and disinfection of instruments. The objectives of this study were to investigate (i) the range of work assignments performed by Danish dental hygienists, (ii) the types of dentist tasks performed by Danish dental hygienists and (iii) job satisfaction among Danish dental hygienists. Dental hygienists graduating in 2004-2007 were invited to participate in this study. Participants answered an email-distributed questionnaire. The questionnaire consisted of questions regarding job satisfaction, assignments performed, postgraduate course attendance, receiving assistance from a dental nurse and which work assignments Danish dental hygienists wish to perform in the future. The results of this study showed that 90% of Danish dental hygienists were satisfied with their job and 52% were performing dentists' tasks. Among dentists' tasks performed by Danish dental hygienists, invasive caries therapy was the most frequently performed task. The type of assignments performed by Danish dental hygienists today appears to be changing compared to previous studies. From initially performing prophylaxis and chair-side assistance for the dentist, Danish dental hygienists today are performing a wider range of tasks which includes dentists' tasks. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  6. Exogenous spatial attention influences figure-ground assignment.

    Science.gov (United States)

    Vecera, Shaun P; Flevaris, Anastasia V; Filapek, Joseph C

    2004-01-01

    In a hierarchical stage account of vision, figure-ground assignment is thought to be completed before the operation of focal spatial attention. Results of previous studies have supported this account by showing that unpredictive, exogenous spatial precues do not influence figure-ground assignment, although voluntary attention can influence figure-ground assignment. However, in these studies, attention was not summoned directly to a region in a figure-ground display. In three experiments, we addressed the relationship between figure-ground assignment and visuospatial attention. In Experiment 1, we replicated the finding that exogenous precues do not influence figure-ground assignment when they direct attention outside of a figure-ground stimulus. In Experiment 2, we demonstrated that exogenous attention can influence figure-ground assignment if it is directed to one of the regions in a figure-ground stimulus. In Experiment 3, we demonstrated that exogenous attention can influence figure-ground assignment in displays that contain a Gestalt figure-ground cue; this result suggests that figure-ground processes are not entirely completed prior to the operation of focal spatial attention. Exogenous spatial attention acts as a cue for figure-ground assignment and can affect the outcome of figure-ground processes.

  7. Reliability of high-voltage pulse capacitors operating in large energy storages

    International Nuclear Information System (INIS)

    Kuchinskij, G.S.; Fedorova, V.S.; Shilin, O.V.

    1982-01-01

    To improve the reliability of pulse capacitors operating in capacitive energy storages, processes, resulting in break-down of capacitor insulation were investigated. A statistic model of failures was constructed and reliability of real capacitors, functioning at operating electric intensity Usub(oper) equal 70 kV/mm and at elevated intensity 90 kV/mm was calculated. Results of testing the IK50-ZU4 capacitor are given. The form of the capacitor service life distribution function was specified. To provide and confirm the assigned capacitor reliability, it is necessary to speed up tests at a higher voltage (1.3-1.5) Usub(oper). To improve the capacitor reliability, it is advisable to conduct acceptance tests, which include hold at increased constant voltage (1.3-1.5) Usub(oper) during 1-3 min and the effect of pulses of increased voltage (1.2-1.3) Usub(oper) with the pulse shape corresponding to operating conditions

  8. Health Services OutPatient Experience questionnaire: factorial validity and reliability of a patient-centered outcome measure for outpatient settings in Italy

    Directory of Open Access Journals (Sweden)

    Coluccia A

    2014-09-01

    Full Text Available Anna Coluccia, Fabio Ferretti, Andrea PozzaDepartment of Medical Sciences, Surgery and Neurosciences, Santa Maria alle Scotte University Hospital, University of Siena, Siena, ItalyPurpose: The patient-centered approach to health care does not seem to be sufficiently developed in the Italian context, and is still characterized by the biomedical model. In addition, there is a lack of validated outcome measures to assess outpatient experience as an aspect common to a variety of settings. The current study aimed to evaluate the factorial validity, reliability, and invariance across sex of the Health Services OutPatient Experience (HSOPE questionnaire, a short ten-item measure of patient-centeredness for Italian adult outpatients. The rationale for unidimensionality of the measure was that it could cover global patient experience as a process common to patients with a variety of diseases and irrespective of the phase of treatment course.Patients and methods: The HSOPE was compiled by 1,532 adult outpatients (51% females, mean age 59.22 years, standard deviation 16.26 receiving care in ten facilities at the Santa Maria alle Scotte University Hospital of Siena, Italy. The sample represented all the age cohorts. Twelve percent were young adults, 57% were adults, and 32% were older adults. Exploratory and confirmatory factor analyses were conducted to evaluate factor structure. Reliability was evaluated as internal consistency using Cronbach’s α. Factor invariance was assessed through multigroup analyses.Results: Both exploratory and confirmatory analyses suggested a clearly defined unidimensional structure of the measure, with all the ten items having salient loadings on a single factor. Internal consistency was excellent (α=0.95. Indices of model fit supported a single-factor structure for both male and female outpatient groups. Young adult outpatients had significantly lower scores on perceived patient-centeredness relative to older adults. No

  9. Experience-based design for integrating the patient care experience into healthcare improvement: Identifying a set of reliable emotion words.

    Science.gov (United States)

    Russ, Lauren R; Phillips, Jennifer; Brzozowicz, Keely; Chafetz, Lynne A; Plsek, Paul E; Blackmore, C Craig; Kaplan, Gary S

    2013-12-01

    Experience-based design is an emerging method used to capture the emotional content of patient and family member healthcare experiences, and can serve as the foundation for patient-centered healthcare improvement. However, a core tool-the experience-based design questionnaire-requires words with consistent emotional meaning. Our objective was to identify and evaluate an emotion word set reliably categorized across the demographic spectrum as expressing positive, negative, or neutral emotions for experience-based design improvement work. We surveyed 407 patients, family members, and healthcare workers in 2011. Participants designated each of 67 potential emotion words as positive, neutral, or negative based on their emotional perception of the word. Overall agreement was assessed using the kappa statistic. Words were selected for retention in the final emotion word set based on 80% simple agreement on classification of meaning across subgroups. The participants were 47.9% (195/407) patients, 19.4% (33/407) family members and 32.7% (133/407) healthcare staff. Overall agreement adjusted for chance was moderate (k=0.55). However, agreement for positive (k=0.69) and negative emotions (k=0.68) was substantially higher, while agreement in the neutral category was low (k=0.11). There were 20 positive, 1 neutral, and 14 negative words retained for the final experience-based design emotion word set. We identified a reliable set of emotion words for experience questionnaires to serve as the foundation for patient-centered, experience-based redesign of healthcare. Incorporation of patient and family member perspectives in healthcare requires reliable tools to capture the emotional content of care touch points. Copyright © 2013 Elsevier Inc. All rights reserved.

  10. Assignment of absolute stereostructures through quantum mechanics electronic and vibrational circular dichroism calculations.

    Science.gov (United States)

    Dai, Peng; Jiang, Nan; Tan, Ren-Xiang

    2016-01-01

    Elucidation of absolute configuration of chiral molecules including structurally complex natural products remains a challenging problem in organic chemistry. A reliable method for assigning the absolute stereostructure is to combine the experimental circular dichroism (CD) techniques such as electronic and vibrational CD (ECD and VCD), with quantum mechanics (QM) ECD and VCD calculations. The traditional QM methods as well as their continuing developments make them more applicable with accuracy. Taking some chiral natural products with diverse conformations as examples, this review describes the basic concepts and new developments of QM approaches for ECD and VCD calculations in solution and solid states.

  11. The Vocal Tract Discomfort Scale: Validity and Reliability of the Persian Version in the Assessment of Patients With Muscle Tension Dysphonia.

    Science.gov (United States)

    Torabi, Hadi; Khoddami, Seyyedeh Maryam; Ansari, Noureddin Nakhostin; Dabirmoghaddam, Payman

    2016-11-01

    To cross-culturally adapt of Persian Vocal Tract Discomfort (VTDp) scale and evaluate its validity and reliability in the assessment of patients with muscle tension dysphonia (MTD). A cross-sectional and prospective cohort design was used to psychometrically test the VTDp. The VTD scale was cross-culturally adapted into Persian language following standard forward-backward translations. The VTDp scale was administrated to 100 patients with MTD (54 men and 46 women; mean age: 38.05 ± 10.02 years) and 50 healthy volunteers (26 men and 24 women; mean age: 36.50 ± 12.27 years). Forty-five patients with MTD completed the VTDp 7 days later for test-retest reliability. Patients also completed the Persian Voice Handicap Index (VHIp) to assess construct validity. The results of discriminative validity demonstrated that the VTDp was able to discriminate between patients with MTD and healthy participants. The internal consistency was confirmed with Cronbach α .77 and 0.73 for VTDp frequency and severity subscales, respectively. The test-retest reliability was excellent with an intraclass correlation coefficient (ICC agreement ) of 0.93 for the frequency subscale and 0.91 for the severity subscale. Construct validity of the VTDp was shown with significant correlations between the VTDp frequency and severity subscales and the VHIp total scores (0.36 and 0.37, respectively). The standard error of measurement and smallest detectable change values for VTDp frequency (2.11 and 5.85, respectively) and severity (2.25 and 6.23, respectively) were acceptable. The Bland-Altman analysis for assessing the agreement between test and retest measurements showed no systematic bias. The VTDp is a valid and reliable self-administered scale to measure patient's vocal tract sensations in Persian-speaking population. Copyright © 2016 The Voice Foundation. Published by Elsevier Inc. All rights reserved.

  12. The reliability of assigning individuals to cognitive states using the Mini Mental-State Examination: a population-based prospective cohort study

    OpenAIRE

    Marioni, Riccardo E.; Chatfield, Mark; Brayne, Carol; Matthews, Fiona E.; Med Res Council

    2011-01-01

    Abstract Background Previous investigations of test re-test reliability of the Mini-Mental State Examination (MMSE) have used correlations and statistics such as Cronbach's α to assess consistency. In practice, the MMSE is usually used to group individuals into cognitive states. The reliability of this grouping (state based approach) has not been fully explored. Methods MMSE data were collected on a subset of 2,275 older participants (≥ 65 years) from the population-based Medical Research Cou...

  13. The reliability and validity of patient-reported chronic obstructive pulmonary disease exacerbations.

    Science.gov (United States)

    Mohan, Arjun; Sethi, Sanjay

    2014-03-01

    Despite the increasing awareness of their pathogenesis and clinical consequences, research on and clinical management of acute exacerbations of chronic obstructive lung disease (AECOPDs) have been hindered by the lack of a consistent and reliable definition. Symptom-based definitions of exacerbations are sensitive to events and account for unreported exacerbations. Event (healthcare utilization)-based definitions are somewhat more definitive but miss unreported events. Objective quantification of symptoms in AECOPD is now possible with the development of the Exacerbations of Chronic Obstructive Pulmonary Disease Tool (EXACT-PRO), a patient-reported outcome (PRO) measure. Several studies have revealed that unreported AECOPDs are more frequent than reported events and are associated with long-term adverse consequences. New antibiotic development for AECOPD has been hampered by the lack of validated measures for resolution of exacerbations. As a result of these observations, a unique collaborative effort between academia, industry and regulatory agencies resulted in the development of the EXACT-PRO. It consists of 14 questions that generate a score between 0 and 100, and it has been shown to have excellent reliability and validity. In the absence of a reliable biomarker, the definition and measurement of exacerbations has been subjective and imprecise. PRO measures such as EXACT can provide much needed objectivity in assessing symptom-defined exacerbations, which may translate into a uniform outcome measure in clinical trials. With further development and validation, it may have a role in clinical practice in the earlier detection of exacerbations, stratification of an exacerbation severity and the assessment of clinical response to treatment.

  14. The use and reliability of SymNose for quantitative measurement of the nose and lip in unilateral cleft lip and palate patients.

    Science.gov (United States)

    Mosmuller, David; Tan, Robin; Mulder, Frans; Bachour, Yara; de Vet, Henrica; Don Griot, Peter

    2016-10-01

    It is essential to have a reliable assessment method in order to compare the results of cleft lip and palate surgery. In this study the computer-based program SymNose, a method for quantitative assessment of the nose and lip, will be assessed on usability and reliability. The symmetry of the nose and lip was measured twice in 50 six-year-old complete and incomplete unilateral cleft lip and palate patients by four observers. For the frontal view the asymmetry level of the nose and upper lip were evaluated and for the basal view the asymmetry level of the nose and nostrils were evaluated. A mean inter-observer reliability when tracing each image once or twice was 0.70 and 0.75, respectively. Tracing the photographs with 2 observers and 4 observers gave a mean inter-observer score of 0.86 and 0.92, respectively. The mean intra-observer reliability varied between 0.80 and 0.84. SymNose is a practical and reliable tool for the retrospective assessment of large caseloads of 2D photographs of cleft patients for research purposes. Moderate to high single inter-observer reliability was found. For future research with SymNose reliable outcomes can be achieved by using the average outcomes of single tracings of two observers. Copyright © 2016 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  15. 1H HR-MAS NMR and S180 cells: metabolite assignment and evaluation of pulse sequence

    International Nuclear Information System (INIS)

    Oliveira, Aline L. de; Martinelli, Bruno César B.; Lião, Luciano M.; Pereira, Flávia C.; Silveira-Lacerda, Elisangela P.; Alcantara, Glaucia B.

    2014-01-01

    High resolution magic angle spinning 1 H nuclear magnetic resonance spectroscopy (HR-MAS NMR) is a useful technique for evaluation of intact cells and tissues. However, optimal NMR parameters are crucial in obtaining reliable results. To identify the key steps for the optimization of HR-MAS NMR parameters, we assessed different pulse sequences and NMR parameters using sarcoma 180 (S180) cells. A complete assignment of the metabolites of S180 is given to assist future studies. (author)

  16. Tracing the geographic origin of traded leopard body parts in the indian subcontinent with DNA-based assignment tests.

    Science.gov (United States)

    Mondol, Samrat; Sridhar, Vanjulavalli; Yadav, Prasanjeet; Gubbi, Sanjay; Ramakrishnan, Uma

    2015-04-01

    Illicit trade in wildlife products is rapidly decimating many species across the globe. Such trade is often underestimated for wide-ranging species until it is too late for the survival of their remaining populations. Policing this trade could be vastly improved if one could reliably determine geographic origins of illegal wildlife products and identify areas where greater enforcement is needed. Using DNA-based assignment tests (i.e., samples are assigned to geographic locations), we addressed these factors for leopards (Panthera pardus) on the Indian subcontinent. We created geography-specific allele frequencies from a genetic reference database of 173 leopards across India to infer geographic origins of DNA samples from 40 seized leopard skins. Sensitivity analyses of samples of known geographic origins and assignments of seized skins demonstrated robust assignments for Indian leopards. We found that confiscated pelts seized in small numbers were not necessarily from local leopards. The geographic footprint of large seizures appeared to be bigger than the cumulative footprint of several smaller seizures, indicating widespread leopard poaching across the subcontinent. Our seized samples had male-biased sex ratios, especially the large seizures. From multiple seized sample assignments, we identified central India as a poaching hotspot for leopards. The techniques we applied can be used to identify origins of seized illegal wildlife products and trade routes at the subcontinent scale and beyond. © 2014 Society for Conservation Biology.

  17. Reliability and Validity of the Pain Anxiety Symptom Scale in Persian Speaking Chronic Low Back Pain Patients.

    Science.gov (United States)

    Shanbehzadeh, Sanaz; Salavati, Mahyar; Tavahomi, Mahnaz; Khatibi, Ali; Talebian, Saeed; Khademi-Kalantari, Khosro

    2017-11-01

    Psychometric testing of the Persian version of Pain Anxiety Symptom Scale 20. The aim of this study was to assess the reliability and construct validity of the PASS-20 in nonspecific chronic low back pain (LBP) patients. The PASS-20 is a self-report questionnaire that assesses pain-related anxiety. The Psychometric properties of this instrument have not been assessed in Persian-speaking chronic LBP patients. One hundred and sixty participants with chronic LBP completed the Persian version of PASS-20, Tampa Scale of Kinesiophobia (TSK), Fear-Avoidance Beliefs Questionnaire (FABQ), Pain Catastrophizing Scale (PCS), trait form of the State-Trait Anxiety (STAI-T), Oswestry Low Back Pain Disability Index (ODI), Beck Depression Inventory (BDI-II), and Visual Analogue Scale (VAS). To evaluate test-retest reliability, 60 patients filled out the PASS-20, 6 to 8 days after the first visit. Test-retest reliability (intraclass correlation coefficient [ICC], standard error of measurement [SEM], and minimal detectable change [MDC]), internal consistency, dimensionality, and construct validity were examined. The ICCs of the PASS-20 subscales and total score ranged from 0.71 to 0.8. The SEMs for PASS-20 total score was 7.29 and for the subscales ranged from 2.43 to 2.98. The MDC for the total score was 20.14 and for the subscales ranged from 6.71 to 8.23. The Cronbach alpha values for the subscales and total score ranged from 0.70 to 0.91. Significant positive correlations were found between the PASS-20 total score and PCS, TSK, FABQ, ODI, BDI, STAI-T, and pain intensity. The Persian version of the PASS-20 showed acceptable psychometric properties for the assessment of pain-related anxiety in Persian-speaking patients with chronic LBP. 3.

  18. Should male gender assignment be considered in the markedly virilized patient With 46,XX and congenital adrenal hyperplasia?

    Science.gov (United States)

    Lee, Peter A; Houk, Christopher P; Husmann, Douglas A

    2010-10-01

    We assess the outcome in 46,XX men with congenital adrenal hyperplasia who were born with Prader 4 or 5 genitalia and assigned male gender at birth. After receiving institutional review board approval and subject consent we reviewed the medical records of 12 men 35 to 69 years old with 46,XX congenital adrenal hyperplasia, of whom 6 completed social and gender issue questionnaires. All subjects were assigned male gender at birth, were diagnosed with virilizing congenital adrenal hyperplasia at age greater than 3 years and indicated a male gender identity with sexual orientation to females. Ten of the 12 subjects had always lived as male and 2 who were reassigned to female gender in childhood subsequently self-reassigned as male. Nine of the 12 men had long-term female partners, including 7 married 12 years or more. The 3 subjects without a long-term female partner included 1 priest, 1 who was reassigned female gender, married, divorced and self-reassigned as male, and 1 with a girlfriend and sexual activity. All except the priest and the subject who was previously married when female indicated a strong libido and frequent orgasmic sexual activity. Responses to self-esteem, masculinity, body image, social adjustment and symptom questionnaires suggested adjustments related to the extent of familial and social support. Outcome data on severely masculinized 46,XX patients with congenital adrenal hyperplasia who were assigned male gender at birth indicate male gender identity in adulthood with satisfactory male sexual function in those retaining male genitalia. In men who completed questionnaires results were poorer in those lacking familial/social support. Male gender of rearing may be a viable option for parents whose children are born with congenital adrenal hyperplasia, a 46,XX karyotype and male genitalia, although positive parental and other support, and counseling are needed for adjustment. Copyright © 2010 American Urological Association Education and Research

  19. WebAssign: Assessing Your Students' Understanding Continuously

    Science.gov (United States)

    Risley, John S.

    1999-11-01

    Motivating students to learn is a constant challenge for faculty. Technology can play a significant role. One such solution is WebAssign — a web-based homework system that offers new teaching and learning opportunities for educators and their students. WebAssign delivers, collects, grades, and records customized homework assignments over the Internet. Students get immediate feedback with credit and instructors can implement "Just-in-Time" teaching. In this talk, I will describe how assignments can be generated with different numerical values for each question, giving each student a unique problem to solve. This feature encourages independent thinking with the benefit of collaborative learning. Example assignments taken from textbook questions and intellectually engaging Java applet simulations will be shown. Studies and first-hand experience on the educational impact of using WebAssign will also be discussed.

  20. Reliability of the discrete choice experiment at the input and output level in patients with rheumatoid arthritis

    DEFF Research Database (Denmark)

    Skjoldborg, Ulla Slothuus; Lauridsen, Jørgen; Junker, Peter

    2009-01-01

    OBJECTIVES: To investigate the issue of conjoint reliability over time. METHODS: A discrete choice experiment was applied using scenarios that describe the effect of treating rheumatoid arthritis patients with TNF-alpha inhibitors, a novel class of highly effective, but expensive antirheumatic...... agents. Respondents participated in three face-to-face interviews over a period of 4 months. Reliability was measured both at the input level, where the consistency of matches made by respondents to the Discrete Choice Experiment (DCE) question between replications was determined, and at the output level...... and the final choice in survey 3. Output level: The confidence intervals for WTP figures in surveys 1 and 2 and 1 and 3 were overlapping, implying that the DCE was reliable at the output level over time. CONCLUSION: The proportion of consistent responses was higher than would be expected by chance. Conjoint...

  1. IMU-to-Segment Assignment and Orientation Alignment for the Lower Body Using Deep Learning.

    Science.gov (United States)

    Zimmermann, Tobias; Taetz, Bertram; Bleser, Gabriele

    2018-01-19

    Human body motion analysis based on wearable inertial measurement units (IMUs) receives a lot of attention from both the research community and the and industrial community. This is due to the significant role in, for instance, mobile health systems, sports and human computer interaction. In sensor based activity recognition, one of the major issues for obtaining reliable results is the sensor placement/assignment on the body. For inertial motion capture (joint kinematics estimation) and analysis, the IMU-to-segment (I2S) assignment and alignment are central issues to obtain biomechanical joint angles. Existing approaches for I2S assignment usually rely on hand crafted features and shallow classification approaches (e.g., support vector machines), with no agreement regarding the most suitable features for the assignment task. Moreover, estimating the complete orientation alignment of an IMU relative to the segment it is attached to using a machine learning approach has not been shown in literature so far. This is likely due to the high amount of training data that have to be recorded to suitably represent possible IMU alignment variations. In this work, we propose online approaches for solving the assignment and alignment tasks for an arbitrary amount of IMUs with respect to a biomechanical lower body model using a deep learning architecture and windows of 128 gyroscope and accelerometer data samples. For this, we combine convolutional neural networks (CNNs) for local filter learning with long-short-term memory (LSTM) recurrent networks as well as generalized recurrent units (GRUs) for learning time dynamic features. The assignment task is casted as a classification problem, while the alignment task is casted as a regression problem. In this framework, we demonstrate the feasibility of augmenting a limited amount of real IMU training data with simulated alignment variations and IMU data for improving the recognition/estimation accuracies. With the proposed

  2. IMU-to-Segment Assignment and Orientation Alignment for the Lower Body Using Deep Learning

    Directory of Open Access Journals (Sweden)

    Tobias Zimmermann

    2018-01-01

    Full Text Available Human body motion analysis based on wearable inertial measurement units (IMUs receives a lot of attention from both the research community and the and industrial community. This is due to the significant role in, for instance, mobile health systems, sports and human computer interaction. In sensor based activity recognition, one of the major issues for obtaining reliable results is the sensor placement/assignment on the body. For inertial motion capture (joint kinematics estimation and analysis, the IMU-to-segment (I2S assignment and alignment are central issues to obtain biomechanical joint angles. Existing approaches for I2S assignment usually rely on hand crafted features and shallow classification approaches (e.g., support vector machines, with no agreement regarding the most suitable features for the assignment task. Moreover, estimating the complete orientation alignment of an IMU relative to the segment it is attached to using a machine learning approach has not been shown in literature so far. This is likely due to the high amount of training data that have to be recorded to suitably represent possible IMU alignment variations. In this work, we propose online approaches for solving the assignment and alignment tasks for an arbitrary amount of IMUs with respect to a biomechanical lower body model using a deep learning architecture and windows of 128 gyroscope and accelerometer data samples. For this, we combine convolutional neural networks (CNNs for local filter learning with long-short-term memory (LSTM recurrent networks as well as generalized recurrent units (GRUs for learning time dynamic features. The assignment task is casted as a classification problem, while the alignment task is casted as a regression problem. In this framework, we demonstrate the feasibility of augmenting a limited amount of real IMU training data with simulated alignment variations and IMU data for improving the recognition/estimation accuracies. With the

  3. Supersonic shear imaging provides a reliable measurement of resting muscle shear elastic modulus

    International Nuclear Information System (INIS)

    Lacourpaille, Lilian; Hug, François; Bouillard, Killian; Nordez, Antoine; Hogrel, Jean-Yves

    2012-01-01

    The aim of the present study was to assess the reliability of shear elastic modulus measurements performed using supersonic shear imaging (SSI) in nine resting muscles (i.e. gastrocnemius medialis, tibialis anterior, vastus lateralis, rectus femoris, triceps brachii, biceps brachii, brachioradialis, adductor pollicis obliquus and abductor digiti minimi) of different architectures and typologies. Thirty healthy subjects were randomly assigned to the intra-session reliability (n = 20), inter-day reliability (n = 21) and the inter-observer reliability (n = 16) experiments. Muscle shear elastic modulus ranged from 2.99 (gastrocnemius medialis) to 4.50 kPa (adductor digiti minimi and tibialis anterior). On the whole, very good reliability was observed, with a coefficient of variation (CV) ranging from 4.6% to 8%, except for the inter-operator reliability of adductor pollicis obliquus (CV = 11.5%). The intraclass correlation coefficients were good (0.871 ± 0.045 for the intra-session reliability, 0.815 ± 0.065 for the inter-day reliability and 0.709 ± 0.141 for the inter-observer reliability). Both the reliability and the ease of use of SSI make it a potentially interesting technique that would be of benefit to fundamental, applied and clinical research projects that need an accurate assessment of muscle mechanical properties. (note)

  4. Reliability and main findings of the FEES-Tensilon Test in patients with myasthenia gravis and dysphagia.

    Science.gov (United States)

    Im, Sun; Suntrup-Krueger, Sonja; Colbow, Sigrid; Sauer, Sonja; Claus, Inga; Meuth, Sven G; Dziewas, Rainer; Warnecke, Tobias

    2018-05-26

    Diagnosis of pharyngeal dysphagia caused by myasthenia gravis (MG) based on clinical examination alone is often challenging. Flexible endoscopic evaluation of swallowing (FEES) combined with Tensilon (edrophonium) application, referred to as the FEES-Tensilon Test, was developed to improve diagnostic accuracy and to detect the main symptoms of pharyngeal dysphagia in MG. Here we investigated inter- and intra-rater reliability of the FEES-Tensilon Test and analyzed the main endoscopic findings. Four experienced raters reviewed a total of 20 FEES-Tensilon-Test videos in randomized order. Residue severity was graded at 4 different pharyngeal spaces before and after Tensilon administration. All interpretations were performed twice per rater, 4 weeks apart (a total of 160 scorings). Intra-rater test-retest reliability and inter-rater reliability levels were calculated. The most frequent FEES findings in MG patients before Tensilon application were prominent residues of semi solids spread all over the hypopharynx in varying locations. The reliability level in the interpretation of the FEES-Tensilon test was excellent regardless of the raters' profession or years of experience with FEES. All 4 raters showed high inter- and intra- reliability levels in interpreting the FEES-Tensilon Test based on residue clearance (kappa=0.922, 0.981). Degree of residue normalization in the vallecular space after Tensilon application showed the highest inter- and intra-rater reliability level (kappa=0.863, 0.957) followed by the epiglottis (kappa=0.813, 0.946) and pyriform sinuses (kappa=0.836, 0.929). Interpretation of the FEES-Tensilon Test based on residue severity and degree of Tensilon clearance, especially in the vallecular space, is consistent and reliable. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  5. The outcome of surgical resection versus assignment to the liver transplant waiting list for hepatocellular carcinoma.

    Science.gov (United States)

    Pierie, Jean-Pierre E N; Muzikansky, Alona; Tanabe, Kenneth K; Ott, Mark J

    2005-07-01

    Optimal management of patients with hepatocellular carcinoma (HCC) is controversial. This study was conducted to evaluate the outcome of tumor resection versus assignment to a liver transplant waiting list (WL) in patients with HCC. Prospectively collected patient data from 1970 to 1997 on 313 patients with HCC were retrospectively analyzed by multivariate analysis to determine the effect of liver disease, method of treatment, and tumor-related factors on survival. A total of 199 patients underwent nonsurgical palliative care (PC), 81 underwent partial liver resection (LR), and 33 were assigned to a liver transplant WL, of which 22 received a donor liver. A total of 91%, 53%, and 91% of the patients had cirrhotic livers in the PC, LR, and WL groups, respectively (P < .001). In the LR group, the absence of a tumor capsule (P < .0001) and a poorly differentiated tumor (P = .027) were both adverse prognostic factors. In the WL group, hepatitis B (P = .02) and American Joint Committee on Cancer tumor stage III (P = .019) were adverse prognostic factors. The 3-year survival rates were 4%, 33%, and 38% for the PC, LR, and WL patients, respectively (P < .0001). The 3-year survival rate in the LR patients was 51% in patients without cirrhosis and 15% in patients with cirrhosis (P < .0001). Patients with locally unresectable tumors, distant disease, or both will continue to receive PC. Patients assigned to liver transplant WLs run the risk of not receiving a donor liver, in which case their survival is predicted to be poor. Survival after resection in a group of patients with advanced tumors is worse than that after transplantation; however, shortages of donor livers presently preclude transplantation in this population of patients.

  6. Reliability-based optimization of an active vibration controller using evolutionary algorithms

    Science.gov (United States)

    Saraygord Afshari, Sajad; Pourtakdoust, Seid H.

    2017-04-01

    Many modern industrialized systems such as aircrafts, rotating turbines, satellite booms, etc. cannot perform their desired tasks accurately if their uninhibited structural vibrations are not controlled properly. Structural health monitoring and online reliability calculations are emerging new means to handle system imposed uncertainties. As stochastic forcing are unavoidable, in most engineering systems, it is often needed to take them into the account for the control design process. In this research, smart material technology is utilized for structural health monitoring and control in order to keep the system in a reliable performance range. In this regard, a reliability-based cost function is assigned for both controller gain optimization as well as sensor placement. The proposed scheme is implemented and verified for a wing section. Comparison of results for the frequency responses is considered to show potential applicability of the presented technique.

  7. Assessing communication quality of consultations in primary care: initial reliability of the Global Consultation Rating Scale, based on the Calgary-Cambridge Guide to the Medical Interview.

    Science.gov (United States)

    Burt, Jenni; Abel, Gary; Elmore, Natasha; Campbell, John; Roland, Martin; Benson, John; Silverman, Jonathan

    2014-03-06

    To investigate initial reliability of the Global Consultation Rating Scale (GCRS: an instrument to assess the effectiveness of communication across an entire doctor-patient consultation, based on the Calgary-Cambridge guide to the medical interview), in simulated patient consultations. Multiple ratings of simulated general practitioner (GP)-patient consultations by trained GP evaluators. UK primary care. 21 GPs and six trained GP evaluators. GCRS score. 6 GP raters used GCRS to rate randomly assigned video recordings of GP consultations with simulated patients. Each of the 42 consultations was rated separately by four raters. We considered whether a fixed difference between scores had the same meaning at all levels of performance. We then examined the reliability of GCRS using mixed linear regression models. We augmented our regression model to also examine whether there were systematic biases between the scores given by different raters and to look for possible order effects. Assessing the communication quality of individual consultations, GCRS achieved a reliability of 0.73 (95% CI 0.44 to 0.79) for two raters, 0.80 (0.54 to 0.85) for three and 0.85 (0.61 to 0.88) for four. We found an average difference of 1.65 (on a 0-10 scale) in the scores given by the least and most generous raters: adjusting for this evaluator bias increased reliability to 0.78 (0.53 to 0.83) for two raters; 0.85 (0.63 to 0.88) for three and 0.88 (0.69 to 0.91) for four. There were considerable order effects, with later consultations (after 15-20 ratings) receiving, on average, scores more than one point higher on a 0-10 scale. GCRS shows good reliability with three raters assessing each consultation. We are currently developing the scale further by assessing a large sample of real-world consultations.

  8. The graded cycling test combined with the talk test is reliable for patients with ischemic heart disease

    DEFF Research Database (Denmark)

    Nielsen, Susanne Grøn; Buus, Lise; Hage, Tine

    2014-01-01

    PURPOSE: To assess relative reliability and measurement error of the Graded Cycling Test (GCT) with the Talk Test (TT) for patients with cardiac disease. METHODS: Patients (N = 64; women, n = 30) with ischemic heart disease performed the GCT with the TT twice in 1 day. Every minute the patient.......81 and 0.88. SEM95 ranged between 17.2 and 18.3 watts (W), with corresponding SRD values between 24.4 and 25.9 W for the patient ratings. The PT ratings ranged between 15.8 and 21.4 W (SEM95) and between 22.3 and 30.3 W (SRD). CONCLUSIONS: The TT, combined with the GCT, was well tolerated by patients...

  9. Assessing the Construct Validity and Internal Reliability of the Screening Tool Test Your Memory in Patients with Chronic Pain.

    Directory of Open Access Journals (Sweden)

    B Ojeda

    Full Text Available Patients with chronic pain often complain about cognitive difficulties, and since these symptoms represent an additional source of suffering and distress, evaluating the cognitive status of these patients with valid and reliable tests should be an important part of their overall assessment. Although cognitive impairment is a critical characteristic of pain, there is no specific measure designed to detect these effects in this population. The objective was to analyze the psychometric properties of the "Test Your Memory" (TYM test in patients with chronic pain of three different origins. A cross-sectional study was carried out on 72 subjects free of pain and 254 patients suffering from different types of chronic pain: neuropathic pain (104, musculoskeletal pain (99 and fibromyalgia (51. The construct validity of the TYM was assessed using the Mini-Mental State Examination (MMSE, Hospital Anxiety and Depression Scale (HADs, Index-9 from MOS-sleep, SF-12, and through the intensity (Visual Analogical Scale and duration of pain. An exploratory factor analysis was also performed and internal reliability was assessed using Cronbach's alpha. After adjusting for potential confounders the TYM could distinguish between pain and pain-free patients, and it was correlated with the: MMSE (0.89, p<0.001; HAD-anxiety (-0.50, p<0.001 and HAD-depression scales (-0.52, p<0.001; MOS-sleep Index-9 (-0.49, p<0.001; and the physical (0.49, p < .001 and mental components (0.55, p < .001 of SF-12. The exploratory structure of the TYM showed an 8-factor solution that explained 53% of the variance, and Cronbach's alpha was 0.66. The TYM is a valid and reliable screening instrument to assess cognitive function in chronic pain patients that will be of particular value in clinical situations.

  10. Reliability and Validity of the Beijing Version of the Montreal Cognitive Assessment in the Evaluation of Cognitive Function of Adult Patients with OSAHS.

    Directory of Open Access Journals (Sweden)

    Xiong Chen

    Full Text Available The patients with obstructive sleep apnea hypopnea syndrome (OSAHS tend to develop cognitive deficits, which usually go unrecognized, and can affect their daily life. The Beijing version of the Montreal cognitive assessment (MoCA-BJ, a Chinese version of MoCA, has been used for the assessment of cognitive functions of OSAHS patients in clinical practice. So far, its reliability and validity have not been tested. This study examined the reliability and validity of MoCA-BJ in a cohort of adult OSAHS patients.152 OSAHS patients, ranging from mild, moderate to severe, 49 primary snoring subjects and 40 normal controls were evaluated for cognitive functions by employing both MoCA-BJ and the Mini Mental State Examination (MMSE. Forty of them were re-tested by MoCA-BJ 14 days after the first test. Internal consistency, test-retest reliability, discriminate and concurrent validity of MoCA-BJ were analyzed.Internal consistency reliability by Cronbach's alpha was adequate (0.73. Intra-class correlation coefficient (ICC, an measure of test-retest reliability, was 0.87 (P<0.001. The total MoCA-BJ scores were significant higher in normal controls than in OSAHS groups (p<0.05. The performances of visuospatial ability in severe OSAHS group were significantly weaker than in normal controls and primary snoring group. The performances of executive ability in severe OSAHS patients were weaker than in normal controls. An optimal cut-off between normal controls and non-normal subjects was at 26 points (total MoCA score. Moreover, cut-off between non-severe and severe OSAHS was at 2 points on visuospatial subscale. Analysis of the correlation between MoCA total scores and MMSE total scores revealed a statistically significant, though relatively weak, correlation (r=0.41, P<0.05.In conclusion, our study showed that the Beijing version of the MoCA was reliable and stable. The MoCA-BJ was capable of detecting cognitive dysfunction by visuospatial and total MoCA-BJ score.

  11. Latent structure and reliability analysis of the measure of body apperception: cross-validation for head and neck cancer patients.

    Science.gov (United States)

    Jean-Pierre, Pascal; Fundakowski, Christopher; Perez, Enrique; Jean-Pierre, Shadae E; Jean-Pierre, Ashley R; Melillo, Angelica B; Libby, Rachel; Sargi, Zoukaa

    2013-02-01

    Cancer and its treatments are associated with psychological distress that can negatively impact self-perception, psychosocial functioning, and quality of life. Patients with head and neck cancers (HNC) are particularly susceptible to psychological distress. This study involved a cross-validation of the Measure of Body Apperception (MBA) for HNC patients. One hundred and twenty-two English-fluent HNC patients between 20 and 88 years of age completed the MBA on a Likert scale ranging from "1 = disagree" to "4 = agree." We assessed the latent structure and internal consistency reliability of the MBA using Principal Components Analysis (PCA) and Cronbach's coefficient alpha (α), respectively. We determined convergent and divergent validities of the MBA using correlations with the Hospital Anxiety and Depression Scale (HADS), observer disfigurement rating, and patients' clinical and demographic variables. The PCA revealed a coherent set of items that explained 38 % of the variance. The Kaiser-Meyer-Olkin measure of sampling adequacy was 0.73 and the Bartlett's test of sphericity was statistically significant (χ (2) (28) = 253.64; p 0.05). The MBA is a valid and reliable screening measure of body apperception for HNC patients.

  12. Accuracy and reliability of the sensory test performed using the laryngopharyngeal endoscopic esthesiometer and rangefinder in patients with suspected obstructive sleep apnoea hypopnoea: protocol for a prospective double-blinded, randomised, exploratory study.

    Science.gov (United States)

    Giraldo-Cadavid, Luis Fernando; Bastidas, Alirio Rodrigo; Padilla-Ortiz, Diana Marcela; Concha-Galan, Diana Carolina; Bazurto, María Angelica; Vargas, Leslie

    2017-08-21

    Patients with obstructive sleep apnoea hypopnoea syndrome (OSA) might have varying degrees of laryngopharyngeal mechanical hyposensitivity that might impair the brain's capacity to prevent airway collapse during sleep. However, this knowledge about sensory compromises in OSA comes from studies performed using methods with little evidence of their validity. Hence, the purpose of this study is to assess the reliability and accuracy of the measurement of laryngopharyngeal mechanosensitivity in patients with OSA using a recently developed laryngopharyngeal endoscopic esthesiometer and rangefinder (LPEER). The study will be prospective and double blinded, with a randomised crossover assignment of raters performing the sensory tests. Subjects will be recruited from patients with suspected OSA referred for baseline polysomnography to a university hospital sleep laboratory. Intra-rater and inter-rater reliability will be evaluated using the Bland-Altman's limits of agreement plot, the intraclass correlation coefficient, and the Pearson or Spearman correlation coefficient, depending on the distribution of the variables. Diagnostic accuracy will be evaluated plotting ROC curves using standard baseline polysomnography as a reference. The sensory threshold values ​​for patients with mild, moderate and severe OSA will be determined and compared using ANOVA or the Kruskal-Wallis test, depending on the distribution of the variables. The LPEER could be a new tool for evaluating and monitoring laryngopharyngeal sensory impairment in patients with OSA. If it is shown to be valid, it could help to increase our understanding of the pathophysiological mechanisms of this condition and potentially help in finding new therapeutic interventions for OSA. The protocol has been approved by the Institutional Review Board of Fundacion Neumologica Colombiana. The results will be disseminated through conference presentations and peer-reviewed publication. This trial was registered at Clinical

  13. Solving the rectangular assignment problem and applications

    NARCIS (Netherlands)

    Bijsterbosch, J.; Volgenant, A.

    2010-01-01

    The rectangular assignment problem is a generalization of the linear assignment problem (LAP): one wants to assign a number of persons to a smaller number of jobs, minimizing the total corresponding costs. Applications are, e.g., in the fields of object recognition and scheduling. Further, we show

  14. 7 CFR 900.106 - Assignment of mediator.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 8 2010-01-01 2010-01-01 false Assignment of mediator. 900.106 Section 900.106 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Marketing... Assignment of mediator. The Director of the Division shall assign a mediator, from the group designated by...

  15. Cross-cultural adaptation and reliability and validity of the Dutch Patient-Rated Tennis Elbow Evaluation (PRTEE-D)

    NARCIS (Netherlands)

    van Ark, Mathijs; Zwerver, Johannes; Diercks, Ronald L; van den Akker-Scheek, Inge

    2014-01-01

    Background: Lateral Epicondylalgia (LE) is a common injury for which no reliable and valid measure exists to determine severity in the Dutch language. The Patient-Rated Tennis Elbow Evaluation (PRTEE) is the first questionnaire specifically designed for LE but in English. The aim of this study was

  16. Reliability of Clinician Rated Physical Effort Determination During Functional Capacity Evaluation in Patients with Chronic Musculoskeletal Pain

    NARCIS (Netherlands)

    Trippolini, M. A.; Dijkstra, P. U.; Jansen, B.; Oesch, P.; Geertzen, J. H. B.; Reneman, M. F.

    Introduction Functional capacity evaluation (FCE) can be used to make clinical decisions regarding fitness-for-work. During FCE the evaluator attempts to assess the amount of physical effort of the patient. The aim of this study is to analyze the reliability of physical effort determination using

  17. Cross-Cultural Translation, Adaptation and Reliability of the Danish M. D. Andeson Dysphagia Inventory (MDADI) in Patients with Head and Neck Cancer.

    Science.gov (United States)

    Hajdú, Sara Fredslund; Plaschke, Christina Caroline; Johansen, Christoffer; Dalton, Susanne Oksbjerg; Wessel, Irene

    2017-08-01

    The objectives were to translate and culturally adapt the M.D. Anderson Dysphagia Inventory (MDADI) into Danish and subsequently test the reliability of the Danish version. The MDADI was translated into Danish and cross culturally adapted through cognitive interviews. The final version was test-retest evaluated in a group of head and neck cancer (HNC) patients who responded to the questionnaire twice with a mean of eight days apart. Interclass correlation coefficient, Cronbach's alpha, floor and ceiling effects, standard error of measurement and minimal detectable change were investigated. Fourteen patients were interviewed on the comprehensibility of the Danish MDADI, and all found the questionnaire meaningful, easy to understand, non-offensive and to include relevant aspects of dysphagia related to HNC. Sixty-four patients were included in the test-retest study. Especially, one item in the emotional scale (E7) appeared to be often misinterpreted, and ceiling effects were found in all four subdomains (global, emotional, functional and physical). The four subdomains and the composite score showed acceptable test-retest reliability and internal consistency in a Danish population of HNC patients. The Danish MDADI is reliable in terms of internal consistency and test-retest reproducibility and can be used in assessing the health-related quality of life in head and neck cancer patients with dysphagia.

  18. Reliability of "Google" for obtaining medical information

    Directory of Open Access Journals (Sweden)

    Mihir Kothari

    2015-01-01

    Full Text Available Internet is used by many patients to obtain relevant medical information. We assessed the impact of "Google" search on the knowledge of the parents whose ward suffered from squint. In 21 consecutive patients, the "Google" search improved the mean score of the correct answers from 47% to 62%. We found that "Google" search was useful and reliable source of information for the patients with regards to the disease etiopathogenesis and the problems caused by the disease. The internet-based information, however, was incomplete and not reliable with regards to the disease treatment.

  19. Transdisciplinary assignments in graduate health education as a model for future collaboration.

    Science.gov (United States)

    Christie, Catherine; Smith, A Russell; Bednarzyk, Michele

    2007-01-01

    Transdisciplinary health care continues to be at the forefront of patient treatment in the medical arena, in part due to escalating health care costs, an increasing aging population, and the development of multiple chronic diseases. Gaining the knowledge, experience, and principles associated with transdisciplinary teamwork to successfully prepare for modern-day practice is therefore essential for individuals of various health care professions. This report describes an assignment developed and implemented to facilitate professional interaction between graduate physical therapy, nutrition, and nursing students. The objectives of this assignment were to determine through student evaluation the effects of a transdisciplinary experience on students' understanding of the role of another discipline and students' communication skills across disciplines. When evaluating the assignment, students most often remarked that they developed a greater understanding of the roles of the included disciplines and reported a significant increase in communication skills. However, some students did not concur that this assignment was effective due to the scheduling conflicts and lack of teamwork that can occur during a collaborative project. The students' reports of their experiences in completing the assignment provide valuable insights for implementing and/or updating a preparatory transdisciplinary education component in other settings. Additional research can focus on the challenges faced by the majority of the students venturing into actual health care or "real-world" settings for comparative studies.

  20. My Favorite Assignment.

    Science.gov (United States)

    ABCA Bulletin, 1983

    1983-01-01

    Describes three assignments for enticing business communication students to undertake library research: an analysis of a Fortune 500 company, a career choice report, and a report on an organization that offers potential employment. (AEA)

  1. Pain Assessment in Critically İll Adult Patients: Validity and Reliability Research of the Turkish Version of the Critical-Care Pain Observation Tool

    Directory of Open Access Journals (Sweden)

    Onur Gündoğan

    2016-12-01

    Full Text Available Objective: Critical-Care Pain Observation Tool (CPOT and the Behavioral Pain Scale (BPS are behavioral pain assessment scales for unconscious intensive care unit (ICU patients. The aim is to determine the validation and reliability of the CPOT in Turkish in mechanically ventilated adult ICU patients. Material and Method: This prospective observational cohort study included 50 mechanically ventilated mixed ICU patients who were unable to report pain. CPOT and BPS was translated into Turkish and language validity was performed by ten intensive care specialists. Pain was assessed in the course of painless and painful routine care procedures using the CPOT and the BPS by a resident and an intensivist concomitantly. Tests reliability, interrater reliability, and validity of the CPOT and the BPS were evaluated. Results: The mean age was 57.4 years and the mean APACHE II score was 18.7. A total of 100 assessments were recorded from 50 patients using CPOT and BPS. Scores of CPOT and BPS during the painful procedures were both significantly higher than painless procedures. The agreement between CPOT and BPS during painful and painless stimuli was ranged as; sensitivity 66.7%-90.3%; specificity 89.7%-97.9%; kappa value 0.712-0.892. The agreement between resident and intensivist during painful and painless stimuli was ranged from 97% to 100% and the kappa value was between 0.904 and 1.0. Conclusion: The Turkish version of the CPOT showed good correlation with the BPS. Interrater reliability between resident and intensivist was good. The study showed that the Turkish version of BPS and CPOT are reliable and valid tools to assess pain in daily clinical practice for intubated and unconscious ICU patients who are mechanically ventilated.

  2. How do cognitively impaired elderly patients define "testament": reliability and validity of the testament definition scale.

    Science.gov (United States)

    Heinik, J; Werner, P; Lin, R

    1999-01-01

    The testament definition scale (TDS) is a specifically designed six-item scale aimed at measuring the respondent's capacity to define "testament." We assessed the reliability and validity of this new short scale in 31 community-dwelling cognitively impaired elderly patients. Interrater reliability for the six items ranged from .87 to .97. The interrater reliability for the total score was .77. Significant correlations were found between the TDS score and the Mini-Mental State Examination (MMSE) and the Cambridge Cognitive Examination scores (r = .71 and .72 respectively, p = .001). Criterion validity yielded significantly different means for subjects with MMSE scores of 24-30 and 0-23: mean 3.9 and 1.6 respectively (t(20) = 4.7, p = .001). Using a cutoff point of 0-2 vs. 3+, 79% of the subjects were correctly classified as severely cognitively impaired, with only 8.3% false positives, and a positive predictive value of 94%. Thus, TDS was found both reliable and valid. This scale, however, is not synonymous with testamentary capacity. The discussion deals with the methodological limitations of this study, and highlights the practical as well as the theoretical relevance of TDS. Future studies are warranted to elucidate the relationships between TDS and existing legal requirements of testamentary capacity.

  3. Possibilities and Limitations of Applying Software Reliability Growth Models to Safety- Critical Software

    International Nuclear Information System (INIS)

    Kim, Man Cheol; Jang, Seung Cheol; Ha, Jae Joo

    2006-01-01

    As digital systems are gradually introduced to nuclear power plants (NPPs), the need of quantitatively analyzing the reliability of the digital systems is also increasing. Kang and Sung identified (1) software reliability, (2) common-cause failures (CCFs), and (3) fault coverage as the three most critical factors in the reliability analysis of digital systems. For the estimation of the safety-critical software (the software that is used in safety-critical digital systems), the use of Bayesian Belief Networks (BBNs) seems to be most widely used. The use of BBNs in reliability estimation of safety-critical software is basically a process of indirectly assigning a reliability based on various observed information and experts' opinions. When software testing results or software failure histories are available, we can use a process of directly estimating the reliability of the software using various software reliability growth models such as Jelinski- Moranda model and Goel-Okumoto's nonhomogeneous Poisson process (NHPP) model. Even though it is generally known that software reliability growth models cannot be applied to safety-critical software due to small number of expected failure data from the testing of safety-critical software, we try to find possibilities and corresponding limitations of applying software reliability growth models to safety critical software

  4. RELIABILITY OF POSITRON EMISSION TOMOGRAPHY-COMPUTED TOMOGRAPHY IN EVALUATION OF TESTICULAR CARCINOMA PATIENTS.

    Science.gov (United States)

    Nikoletić, Katarina; Mihailović, Jasna; Matovina, Emil; Žeravica, Radmila; Srbovan, Dolores

    2015-01-01

    The study was aimed at assessing the reliability of 18F-fluorodeoxyglucose positron emission tomography-computed tomography scan in evaluation of testicular carcinoma patients. The study sample consisted of 26 scans performed in 23 patients with testicular carcinoma. According to the pathohistological finding, 14 patients had seminomas, 7 had nonseminomas and 2 patients had a mixed histological type. In 17 patients, the initial treatment was orchiectomy+chemotherapy, 2 patients had orchiectomy+chemotherapy+retroperitoneal lymph node dissection, 3 patients had orchiectomy only and one patient was treated with chemotherapy only. Abnormal computed tomography was the main cause for the oncologist to refer the patient to positron emission tomography-computed tomography scan (in 19 scans), magnetic resonance imaging abnormalities in 1 scan, high level oftumor markers in 3 and 3 scans were perforned for follow-up. Positron emission tomography-computed tomography imaging results were compared with histological results, other imaging modalities or the clinical follow-up of the patients. Positron emission tomography-computed tomography scans were positive in 6 and negative in 20 patients. In two patients, positron emission tomography-computed tomography was false positive. There were 20 negative positron emission omography-computed tomography scans perforned in 18 patients, one patient was lost for data analysis. Clinically stable disease was confirmed in 18 follow-up scans performed in 16 patients. The values of sensitivty, specificity, accuracy, and positive- and negative predictive value were 60%, 95%, 75%, 88% and 90.5%, respectively. A hgh negative predictive value obtained in our study (90.5%) suggests that there is a small possibility for a patient to have future relapse after normal positron emission tomography-computed tomography study. However, since the sensitivity and positive predictive value of the study ire rather low, there are limitations of positive

  5. Validity and reliability of the Brief version of Quality of Life in Bipolar Disorder" (Bref QoL.BD) among Chinese bipolar patients.

    Science.gov (United States)

    Xiao, Lin; Gao, Yulin; Zhang, Lili; Chen, Peiyun; Sun, Xiaojia; Tang, Siyuan

    2016-03-15

    Previous literatures on quality of life (QoL) in bipolar disorder (BD) strongly suggested that a disease-specific QoL measure for patients with BD should be developed to evaluate QoL more specifically and reliably. To our knowledge, "Quality of Life in Bipolar Disorder" (QoL.BD) is the first and only questionnaire produced to specifically measure QoL in people with BD. In China, there is no disease-targeted measure available to specifically measure QoL in Chinese patients with BD. The aim of the study is to revise and validate the brief version of the QoL.BD (Bref QoL.BD ) into Chinese version. All the items of the Bref QoL.BD was translated into Chinese language, using the Brislin translation mode. The questionnaire was administered to a total sample of 231 subjects, including 101 BD patients and 130 healthy controls, to test the psychometric properties of Bref QoL.BD (e.g. internal consistency, retest reliability, content validity, item analysis, confirmatory factor analysis, criterion validity, convergent validity, discriminative validity and feasibility). The Chinese version of the Bref QoL.BD had very high internal consistency (Cronbach's alpha=0.815) and retest reliability (intraclass correlation coefficient (ICC )=0.808). Confirmatory factor analysis (CFA) validated the original one-factor structure. The direction and magnitude of correlations with 36-item Short-Form Health Survey (SF-36; rs= 0.313, Psize from only one tertiary care center. And BD patients enrolled were euthymic, excluding the acute BD patients. The Chinese version of the Bref QoL.BD is a feasible, reliable and valid tool for the assessment of QoL for Chinese BD patients. Copyright © 2015 Elsevier B.V. All rights reserved.

  6. Parentage assignment with genomic markers: a major advance for understanding and exploiting genetic variation of quantitative traits in farmed aquatic animals

    Directory of Open Access Journals (Sweden)

    Marc eVandeputte

    2014-12-01

    Full Text Available Since the middle of the 1990s, parentage assignment using microsatellite markers has been introduced as a tool in aquaculture breeding. It now allows close to 100% assignment success, and offered new ways to develop aquaculture breeding using mixed family designs in industry conditions. Its main achievements are the knowledge and control of family representation and inbreeding, especially in mass spawning species, above all the capacity to estimate reliable genetic parameters in any species and rearing system with no prior investment in structures, and the development of new breeding programs in many species. Parentage assignment should not be seen as a way to replace physical tagging, but as a new way to conceive breeding programs, which have to be optimized with its specific constraints, one of the most important being to well define the number of individuals to genotype to limit costs, maximize genetic gain while minimizing inbreeding. The recent possible shift to (for the moment more costly SNP markers should benefit from future developments in genomics and MAS selection to combine parentage assignment and indirect prediction of breeding values.

  7. Validity and reliability of the Dutch version of the Copenhagen Hip And Groin Outcome Score (HAGOS-NL in patients with hip pathology.

    Directory of Open Access Journals (Sweden)

    Hilde Giezen

    Full Text Available The Copenhagen Hip And Groin Outcome Score (HAGOS was developed to assess disease-specific consequences in young to middle-aged, physically active hip and/or groin patients. The study aimed to determine validity and reliability of the Dutch version of the HAGOS (HAGOS-NL for middle-aged patients with hip complaints.To assess validity, 117 participants completed five questionnaires: HAGOS-NL, international Hip Outcome Tool (iHOT-12NL, Hip disability and Osteoarthritis Outcome Score (HOOS, RAND-36 Health Survey and Tegner activity scale. Structural validity was determined by conducting confirmatory factor analysis. Construct validity was analyzed by formulating predefined hypotheses regarding relationships between the HAGOS-NL and subscales of the iHOT-12NL, HOOS, RAND-36 and Tegner activity scale. The HAGOS-NL was filled out again by 67 patients to explore test-retest reliability. Reliability was assessed in terms of Cronbach's alpha, Intraclass Correlation Coefficient (ICC, Standard Error of Measurement (SEM and Minimal Detectable Change (MDC. The Bland and Altman method was used to explore absolute agreement.Factor analysis confirmed that the HAGOS-NL consists of six subscales. All hypotheses were confirmed, indicating good construct validity. Internal consistency was good, with Cronbach's alpha values ranging from 0.89 to 0.98. Test-retest reliability was considered good, with ICC values of 0.80 and higher. The SEM ranged from 6.6 to 12.3, and MDC at individual level from 18.3 to 34.1 and at group level from 2.3 to 4.4. Bland and Altman analyses showed no bias.The HAGOS-NL is a reliable and valid instrument for measuring pain, physical functioning and quality of life in middle-aged patients with hip complaints.

  8. Cross-cultural adaptation and reliability and validity of the Dutch Patient-Rated Tennis Elbow Evaluation (PRTEE-D).

    Science.gov (United States)

    van Ark, Mathijs; Zwerver, Johannes; Diercks, Ronald L; van den Akker-Scheek, Inge

    2014-08-11

    Lateral Epicondylalgia (LE) is a common injury for which no reliable and valid measure exists to determine severity in the Dutch language. The Patient-Rated Tennis Elbow Evaluation (PRTEE) is the first questionnaire specifically designed for LE but in English. The aim of this study was to translate into Dutch and cross-culturally adapt the PRTEE and determine reliability and validity of the PRTEE-D (Dutch version). The PRTEE was cross-culturally adapted according to international guidelines. Participants (n = 122) were asked to fill out the PRTEE-D twice with a one week interval to assess test-retest reliability. Internal consistency of the PRTEE-D was determined by calculating Crohnbach's alphas for the questionnaire and subscales. Intraclass Correlation Coefficients (ICC) were calculated for the overall PRTEE-D score, pain and function subscale and individual questions to determine test-retest reliability. Additionally, the Disabilities for the Arm, Shoulder and Hand questionnaire (DASH) and Visual Analogue Scale (VAS) pain scores were obtained from 30 patients to assess construct validity; Spearman's correlation coefficients were calculated between the PRTEE-D (subscales) and DASH and VAS-pain scores. The PRTEE was successfully cross-culturally adapted into Dutch (PRTEE-D). Crohnbach's alpha for the first assessment of the PRTEE-D was 0.98; Crohnbach's alpha was 0.93 for the pain subscale and 0.97 for the function subscale. ICC for the PRTEE-D was 0.98; subscales also showed excellent ICC values (pain scale 0.97 and function scale 0.97). A significant moderate correlation exists between PRTEE-D and DASH (0.65) and PRTEE-D and VAS pain (0.68). The PRTEE was successfully cross-culturally adapted and this study showed that the PRTEE-D is reliable and valid to obtain an indication of severity of LE. An easy-to-use instrument for practitioners is now available and this facilitates comparing Dutch and international research data.

  9. Structural and reliability analysis of quality of relationship index in cancer patients.

    Science.gov (United States)

    Cousson-Gélie, Florence; de Chalvron, Stéphanie; Zozaya, Carole; Lafaye, Anaïs

    2013-01-01

    Among psychosocial factors affecting emotional adjustment and quality of life, social support is one of the most important and widely studied in cancer patients, but little is known about the perception of support in specific significant relationships in patients with cancer. This study examined the psychometric properties of the Quality of Relationship Inventory (QRI) by evaluating its factor structure and its convergent and discriminant validity in a sample of cancer patients. A total of 388 patients completed the QRI. Convergent validity was evaluated by testing the correlations between the QRI subscales and measures of general social support, anxiety and depression symptoms. Discriminant validity was examined by testing group comparison. The QRI's longitudinal invariance across time was also tested. Principal axis factor analysis with promax rotation identified three factors accounting for 42.99% of variance: perceived social support, depth, and interpersonal conflict. Estimates of reliability with McDonald's ω coefficient were satisfactory for all the QRI subscales (ω ranging from 0.75 - 0.85). Satisfaction from general social support was negatively correlated with the interpersonal conflict subscale and positively with the depth subscale. The interpersonal conflict and social support scales were correlated with depression and anxiety scores. We also found a relative stability of QRI subscales (measured 3 months after the first evaluation) and differences between partner status and gender groups. The Quality of Relationship Inventory is a valid tool for assessing the quality of social support in a particular relationship with cancer patients.

  10. {sup 1}H HR-MAS NMR and S180 cells: metabolite assignment and evaluation of pulse sequence

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Aline L. de; Martinelli, Bruno César B.; Lião, Luciano M. [Universidade Federal de Goiás (UFG), Goiânia, GO (Brazil). Instituto de Química. Lab. de RMN; Pereira, Flávia C.; Silveira-Lacerda, Elisangela P. [Universidade Federal de Goiás (UFG), Goiânia, GO (Brazil). Instituto de Ciências Biológicas. Laboratório Genética Molecular e Citogenética; Alcantara, Glaucia B., E-mail: glaucia.alcantara@ufms.br [Universidade Federal de Mato Grosso do Sul (UFMS), Campo Grande, MS (Brazil). Inst. de Química

    2014-07-01

    High resolution magic angle spinning {sup 1}H nuclear magnetic resonance spectroscopy (HR-MAS NMR) is a useful technique for evaluation of intact cells and tissues. However, optimal NMR parameters are crucial in obtaining reliable results. To identify the key steps for the optimization of HR-MAS NMR parameters, we assessed different pulse sequences and NMR parameters using sarcoma 180 (S180) cells. A complete assignment of the metabolites of S180 is given to assist future studies. (author)

  11. Problems Related to Use of Some Terms in System Reliability Analysis

    Directory of Open Access Journals (Sweden)

    Nadezda Hanusova

    2004-01-01

    Full Text Available The paper deals with problems of using dependability terms, defined in actual standard STN IEC 50 (191: International electrotechnical dictionary, chap. 191: Dependability and quality of service (1993, in a technical systems dependability analysis. The goal of the paper is to find a relation between terms introduced in the mentioned standard and used in the technical systems dependability analysis and rules and practices used in a system analysis of the system theory. Description of a part of the system life cycle related to reliability is used as a starting point. The part of a system life cycle is described by the state diagram and reliability relevant therms are assigned.

  12. Reliability and Validity of Prototype Diagnosis for Adolescent Psychopathology.

    Science.gov (United States)

    Haggerty, Greg; Zodan, Jennifer; Mehra, Ashwin; Zubair, Ayyan; Ghosh, Krishnendu; Siefert, Caleb J; Sinclair, Samuel J; DeFife, Jared

    2016-04-01

    The current study investigated the interrater reliability and validity of prototype ratings of 5 common adolescent psychiatric disorders: attention-deficit/hyperactivity disorder, conduct disorder, major depressive disorder, generalized anxiety disorder, and posttraumatic stress disorder. One hundred fifty-seven adolescent inpatient participants consented to participate in this study. We compared ratings from 2 inpatient clinicians, blinded to each other's ratings and patient measures, after their separate initial diagnostic interview to assess interrater reliability. Prototype ratings completed by clinicians after their initial diagnostic interview with adolescent inpatients and outpatients were compared with patient-reported behavior problems and parents' report of their child's behavioral problems. Prototype ratings demonstrated good interrater reliability. Clinicians' prototype ratings showed predicted relationships with patient-reported behavior problems and parent-reported behavior problems. Prototype matching seems to be a possible alternative for psychiatric diagnosis. Prototype ratings showed good interrater reliability based on clinicians unique experiences with the patient (as opposed to video-/audio-recorded material) with no training.

  13. Managing voluntary turnover through challenging assignments

    NARCIS (Netherlands)

    Preenen, P.T.Y.; de Pater, I.E.; van Vianen, A.E.M.; Keijzer, L.

    2011-01-01

    This study examines employees’ challenging assignments as manageable means to reduce turnover intentions, job search behaviors, and voluntary turnover. Results indicate that challenging assignments are negatively related to turnover intentions and job search behaviors and that these relationships

  14. Managing voluntary turnover through challenging assignments

    NARCIS (Netherlands)

    Preenen, P.T.Y.; Pater, I.E. de; Vianen, A.E.M. van; Keijzer, L.

    2011-01-01

    This study examines employees' challenging assignments as manageable means to reduce turnover intentions, job search behaviors, and voluntary turnover. Results indicate that challenging assignments are negatively related to turnover intentions and job search behaviors and that these relationships

  15. Validity and reliability of the Japanese version of the Caregiver Reaction Assessment Scale (CRA-J) for community-dwelling cancer patients.

    Science.gov (United States)

    Misawa, Tomoyo; Miyashita, Mitsunori; Kawa, Masako; Abe, Koji; Abe, Mayumi; Nakayama, Yasuko; Given, Charles W

    2009-01-01

    The aim of this study was to validate the Caregiver Reaction Assessment (CRA) among caregivers of community-dwelling advanced cancer patients in Japan. A cross-sectional questionnaire was administered to advanced cancer patients and their caregivers who were cared for at day hospices and home palliative care services. We translated the CRA into Japanese, and then verified factor validity, reliability, construct validity, concurrent validity, and known groups' validity. To address construct and concurrent validity, we calculated Pearson's correlation coefficient between the Japanese version of the CRA and the Burden Index of Caregivers (BIC). To address known groups' validity, we used the t test or analysis of variance (ANOVA). A total of 57 caregivers participated in the study. Five factors were extracted (''impact on schedule,'' ''caregiver's self-esteem,'' ''lack of family support,'' ''impact on health,'' and ''impact on finances'') and reliability was good. Construct and concurrent validity among the subscales of the BIC were good. Regarding known groups validity, the subscale score of ''impact on schedule'' for the groups that cared 6 hours or more per day was higher than the other group (P = .04). The CRA-J is valid and reliable. This scale is useful for caregivers of cancer patients in Japan.

  16. Reliability of a treatment-based classification system for subgrouping people with low back pain.

    Science.gov (United States)

    Henry, Sharon M; Fritz, Julie M; Trombley, Andrea R; Bunn, Janice Y

    2012-09-01

    Observational, cross-sectional reliability study. To examine the interrater reliability of novice raters in their use of the treatment-based classification (TBC) system for low back pain and to explore the patterns of disagreement in classification errors. Although the interrater reliability of individual test items in the TBC system is moderate to good, some error persists in classification decision making. Understanding which classification errors are common could direct further refinement of the TBC system. Using previously recorded patient data (n = 24), 12 novice raters classified patients according to the TBC schema. These classification results were combined with those of 7 other raters, allowing examination of the overall agreement using the kappa statistic, as well as agreement/disagreement among pairwise comparisons in classification assignments. A chi-square test examined differences in percent agreement between the novice and more experienced raters and differences in classification distributions between these 2 groups of raters. Among 12 novice raters, there was 80.9% agreement in the pairs of classification (κ = 0.62; 95% confidence interval: 0.59, 0.65) and an overall 75.5% agreement (κ = 0.57; 95% confidence interval: 0.55, 0.69) for the combined data set. Raters were least likely to agree on a classification of stabilization (77.5% agreement). The overall percentage of pairwise classification judgments that disagreed was 24.5%, with the most common disagreement being between manipulation and stabilization (11.0%), followed by a mismatch between stabilization and specific exercise (8.2%). Additional refinement is needed to reduce rater disagreement that persists in the TBC decision-making algorithm, particularly in the stabilization category. J Orthop Sports Phys Ther 2012;42(9):797-805, Epub 7 June 2012. doi:10.2519/jospt.2012.4078.

  17. Design and reliability of a didactic inphographic rubric assessment

    Directory of Open Access Journals (Sweden)

    Yunuen Ixchel GUZMÁN-CEDILLO

    2017-12-01

    Full Text Available The objective of this study is to describe design, validity process and reliability of a rubric assessment to evaluate didactic infographics quality. Participants were fifteen judges who participate in different moments of elaboration rubric process; it was made in three process phases: design, settings and reliability determination. Content validity was obtained by percentage agreement between 3 judges by component of the rubric; likewise a Krippendorff’s alpha were applied (a = .710 in pilot assessment with 5 infographics in order to set possible writings contradictions between components and criteria of performance. The intern consistence was determined by Cronbach’s alpha (? = .806 in 22 infographics gradation. An Intraclass correlation coefficient icc (a = .909 was applied to 6 judges qualifications also a Krippendorff’s alpha (a = .538 both of them in ordinal levels. The rubric is composed by 9 components, 3 performance levels, definitions of each component and assignments how to use the rubric. Results suggest the rubric is valid and reliable to grade quality of didactic infographic.

  18. The reliability of measuring pain distribution and location using body pain diagrams in patients with acute whiplash-associated disorders.

    Science.gov (United States)

    Southerst, Danielle; Stupar, Maja; Côté, Pierre; Mior, Silvano; Stern, Paula

    2013-09-01

    The objective of this study was to measure the interexaminer reliability of scoring pain distribution using paper and electronic body pain diagrams in patients with acute whiplash-associated disorder and to assess the intermethod reliability of measuring pain distribution and location using paper and electronic diagrams. We conducted an interexaminer reliability study on 80 participants recruited from a randomized controlled trial on the conservative management of acute grade I/II whiplash-associated disorder. Participants were assessed for inclusion/exclusion criteria by an experienced clinician. As part of the baseline assessment, participants independently completed paper and electronic pain diagrams. Diagrams were scored independently by 2 examiners using the body region method. Interexaminer and intermethod reliability was computed using intraclass correlation coefficients (ICCs) for pain distribution and κ coefficient for pain location. We used Bland-Altman plots to compute limits of agreement. The interexaminer reliability was ICC = 0.925 for paper and ICC = 0.997 for the electronic body pain diagram. The intermethod reliability for measuring pain distribution ranged from ICC = 0.63 to ICC = 0.93. For pain location, the intermethod reliability varied from κ = 0.23 (posterior neck) to κ = 0.90 (right side of the face). We found good to excellent interexaminer reliability for scoring 2 versions of the body pain diagram. Pain distribution and pain location were reliably and consistently measured on body pain diagrams using paper and electronic methods; therefore, clinicians and researchers may choose either medium when using body pain diagrams. Copyright © 2013 National University of Health Sciences. Published by Mosby, Inc. All rights reserved.

  19. Reliable assessment of general surgeons' non-technical skills based on video-recordings of patient simulated scenarios.

    Science.gov (United States)

    Spanager, Lene; Beier-Holgersen, Randi; Dieckmann, Peter; Konge, Lars; Rosenberg, Jacob; Oestergaard, Doris

    2013-11-01

    Nontechnical skills are essential for safe and efficient surgery. The aim of this study was to evaluate the reliability of an assessment tool for surgeons' nontechnical skills, Non-Technical Skills for Surgeons dk (NOTSSdk), and the effect of rater training. A 1-day course was conducted for 15 general surgeons in which they rated surgeons' nontechnical skills in 9 video recordings of scenarios simulating real intraoperative situations. Data were gathered from 2 sessions separated by a 4-hour training session. Interrater reliability was high for both pretraining ratings (Cronbach's α = .97) and posttraining ratings (Cronbach's α = .98). There was no statistically significant development in assessment skills. The D study showed that 2 untrained raters or 1 trained rater was needed to obtain generalizability coefficients >.80. The high pretraining interrater reliability indicates that videos were easy to rate and Non-Technical Skills for Surgeons dk easy to use. This implies that Non-Technical Skills for Surgeons dk (NOTSSdk) could be an important tool in surgical training, potentially improving safety and quality for surgical patients. Copyright © 2013 Elsevier Inc. All rights reserved.

  20. "Why bother so incredibly much?": student perspectives on PISA science assignments

    Science.gov (United States)

    Serder, Margareta; Jakobsson, Anders

    2015-09-01

    Large-scale assessment, such as the Programme for International Assessment (PISA), plays an increasingly important role in current educational practice and politics. However, many scholars have questioned the validity and reliability of the tests and the extent to which they actually constitute trustworthy representations of students' knowledge. In the light of such critical voices the present article adopts a sociocultural perspective of human knowledge and action in order to explore the encounters between students and the science test assignments with which their knowledge is tested. Of particular interest in this study are the described "real-life situations" presented as the relevant background in which scientific literacy is assessed in PISA. According to the sociocultural theoretical onset the methodology used to approach the students' meaning making of the image of science as portrayed in the test were collaborative situations in which students work in small groups with units of PISA assignments, enabling a study of student-assignment encounters in action. The data we worked with consists of video-recordings from 71 Swedish 15-year-old students working with three released units from the PISA science test. According to our analysis, the "real-life situations" described in the test emerge as problematic in the students' meaning-making. This is demonstrated for instance by the students' positioning themselves as being different from and opposed to the fictional pictured students who appear in the backstories of the test. This article provides examples of how the scientific and academic language used by the fictional students in the assignments mediates distance and resistance among the students. The fictional students' use of strict scientific language and methods in day-to-day life situations leads them to be perceived as "little scientists" and as elite stereotypes of the scientific culture. We conclude that, by using assignments of this type, measurements of

  1. Scaffolding students’ assignments

    DEFF Research Database (Denmark)

    Slot, Marie Falkesgaard

    2013-01-01

    This article discusses scaffolding in typical student assignments in mother tongue learning materials in upper secondary education in Denmark and the United Kingdom. It has been determined that assignments do not have sufficient scaffolding end features to help pupils understand concepts and build...... objects. The article presents the results of empirical research on tasks given in Danish and British learning materials. This work is based on a further development of my PhD thesis: “Learning materials in the subject of Danish” (Slot 2010). The main focus is how cognitive models (and subsidiary explicit...... learning goals) can help students structure their argumentative and communica-tive learning processes, and how various multimodal representations can give more open-ended learning possibilities for collaboration. The article presents a short introduction of the skills for 21st century learning and defines...

  2. Reliability of EEG Interactions Differs between Measures and Is Specific for Neurological Diseases

    Directory of Open Access Journals (Sweden)

    Yvonne Höller

    2017-07-01

    Full Text Available Alterations of interaction (connectivity of the EEG reflect pathological processes in patients with neurologic disorders. Nevertheless, it is questionable whether these patterns are reliable over time in different measures of interaction and whether this reliability of the measures is the same across different patient populations. In order to address this topic we examined 22 patients with mild cognitive impairment, five patients with subjective cognitive complaints, six patients with right-lateralized temporal lobe epilepsy, seven patients with left lateralized temporal lobe epilepsy, and 20 healthy controls. We calculated 14 measures of interaction from two EEG-recordings separated by 2 weeks. In order to characterize test-retest reliability, we correlated these measures for each group and compared the correlations between measures and between groups. We found that both measures of interaction as well as groups differed from each other in terms of reliability. The strongest correlation coefficients were found for spectrum, coherence, and full frequency directed transfer function (average rho > 0.9. In the delta (2–4 Hz range, reliability was lower for mild cognitive impairment compared to healthy controls and left lateralized temporal lobe epilepsy. In the beta (13–30 Hz, gamma (31–80 Hz, and high gamma (81–125 Hz frequency ranges we found decreased reliability in subjective cognitive complaints compared to mild cognitive impairment. In the gamma and high gamma range we found increased reliability in left lateralized temporal lobe epilepsy patients compared to healthy controls. Our results emphasize the importance of documenting reliability of measures of interaction, which may vary considerably between measures, but also between patient populations. We suggest that studies claiming clinical usefulness of measures of interaction should provide information on the reliability of the results. In addition, differences between patient

  3. Validity and reliability of 3D US for the detection of erosions in patients with rheumatoid arthritis using MRI as the gold standard

    DEFF Research Database (Denmark)

    Ellegaard, K; Bliddal, H; Møller Døhn, U

    2014-01-01

    PURPOSE: To test the reliability and validity of a 3D US erosion score in RA using MRI as the gold standard. MATERIALS AND METHODS: RA patients were examined with 3D US and 3 T MRI over the 2nd and 3rd metacarpophalangeal joints. 3D blocks were evaluated by two investigators. The erosions were...... estimated according to a semi-quantitative score (SQS) (0 - 3) and a quantitative score (QS) (mm²). MRI was evaluated according to the RAMRIS score. For the estimation of reliability, intra-class correlation coefficients (ICC) were used. Validity was tested using Spearman's rho (rs). The sensitivity...... and specificity were also calculated. RESULTS: 28 patients with RA were included. The ICC for the inter-observer reliability in the QS was 0.41 and 0.13 for the metacarpal bone and phalangeal bone, respectively, and 0.86 and 0.16, respectively, in the SQS.  The ICC for the intra-observer reliability in the QS...

  4. Reliability and known-group validity of the Arabic version of the 8-item Morisky Medication Adherence Scale among type 2 diabetes mellitus patients.

    Science.gov (United States)

    Ashur, S T; Shamsuddin, K; Shah, S A; Bosseri, S; Morisky, D E

    2015-12-13

    No validation study has previously been made for the Arabic version of the 8-item Morisky Medication Adherence Scale (MMAS-8(©)) as a measure for medication adherence in diabetes. This study in 2013 tested the reliability and validity of the Arabic MMAS-8 for type 2 diabetes mellitus patients attending a referral centre in Tripoli, Libya. A convenience sample of 103 patients self-completed the questionnaire. Reliability was tested using Cronbach alpha, average inter-item correlation and Spearman-Brown coefficient. Known-group validity was tested by comparing MMAS-8 scores of patients grouped by glycaemic control. The Arabic version showed adequate internal consistency (α = 0.70) and moderate split-half reliability (r = 0.65). Known-group validity was supported as a significant association was found between medication adherence and glycaemic control, with a moderate effect size (ϕc = 0.34). The Arabic version displayed good psychometric properties and could support diabetes research and practice in Arab countries.

  5. The Cambridge Otology Quality of Life Questionnaire: an otology-specific patient-recorded outcome measure. A paper describing the instrument design and a report of preliminary reliability and validity.

    Science.gov (United States)

    Martin, T P C; Moualed, D; Paul, A; Ronan, N; Tysome, J R; Donnelly, N P; Cook, R; Axon, P R

    2015-04-01

    The Cambridge Otology Quality of Life Questionnaire (COQOL) is a patient-recorded outcome measurement (PROM) designed to quantify the quality of life of patients attending otology clinics. Item-reduction model. A systematically designed long-form version (74 items) was tested with patient focus groups before being presented to adult otology patients (n. 137). Preliminary item analysis tested reliability, reducing the COQOL to 24 questions. This was then presented in conjunction with the SF-36 (V1) questionnaire to a total of 203 patients. Subsequently, these were re-presented at T + 3 months, and patients recorded whether they felt their condition had improved, deteriorated or remained the same. Non-responders were contacted by post. A correlation between COQOL scores and patient perception of change was examined to analyse content validity. Teaching hospital and university psychology department. Adult patients attending otology clinics with a wide range of otological conditions. Item reliability measured by item–total correlation, internal consistency and test– retest reliability. Validity measured by correlation between COQOL scores and patient-reported symptom change. Reliability: the COQOL showed excellent internal consistency at both initial presentation (a = 0.90) and 3 months later (a = 0.93). Validity: One-way analysis of variance showed a significant difference between groups reporting change and those reporting no change in quality of life (F(2, 80) = 5.866, P < 0.01). The COQOL is the first otology-specific PROM. Initial studies demonstrate excellent reliability and encouraging preliminary criterion validity: further studies will allow a deeper validation of the instrument.

  6. Intra- and inter-rater reliabilities of measurement of ultrasound imaging for muscle thickness and pennation angle of tibialis anterior muscle in stroke patients.

    Science.gov (United States)

    Cho, Ki Hun; Lee, Hwang Jae; Lee, Wan Hee

    2017-07-01

    Dysfunction of skeletal muscle has been commonly reported in stroke patients. The purpose of this study was to investigate the intra- and inter-rater reliabilities of measurement of ultrasound imaging (USI) for pennation angle (PA) and muscle thickness (MT) of tibialis anterior muscle in stroke patients. Thirty-four stroke patients (19 men) participated in this study. USI was used for measurement of PA and MT of the tibialis anterior muscles at rest and during maximum voluntary contraction (MVC). Two examiners acquired images from all participants during two separate testing sessions, seven days apart. Intra-class correlation coefficients (ICCs), confidence interval (CI), standard error of measurement, minimal detectable change, and Bland-Altman plots were used for estimation of reliability. In the intra-rater reliability between measures, for all variables (PA and MT of the paretic and non-paretic sides of tibialis anterior muscles at rest and during MVC), the ICCs ranged between 0.639 and 0.998 and the CI was within an acceptable range of 0.388-0.999. In inter-rater reliability between examiners for the two tests, for all variables, the ICCs ranged between 0.690 and 0.995 and the CI was within an acceptable range of 0.463-0.997. In addition, significant difference was observed between the paretic and non-paretic sides of the tibialis anterior muscle architecture (p stroke patients. In addition, objective and quantitative measurements of tibialis anterior muscle using USI may provide appropriate management for the walking recovery of stroke patients.

  7. Mars - robust automatic backbone assignment of proteins

    International Nuclear Information System (INIS)

    Jung, Young-Sang; Zweckstetter, Markus

    2004-01-01

    MARS a program for robust automatic backbone assignment of 13 C/ 15 N labeled proteins is presented. MARS does not require tight thresholds for establishing sequential connectivity or detailed adjustment of these thresholds and it can work with a wide variety of NMR experiments. Using only 13 C α / 13 C β connectivity information, MARS allows automatic, error-free assignment of 96% of the 370-residue maltose-binding protein. MARS can successfully be used when data are missing for a substantial portion of residues or for proteins with very high chemical shift degeneracy such as partially or fully unfolded proteins. Other sources of information, such as residue specific information or known assignments from a homologues protein, can be included into the assignment process. MARS exports its result in SPARKY format. This allows visual validation and integration of automated and manual assignment

  8. Intrarater reliabilities of shoulder joint horizontal adductor muscle strength measurements using a handheld dynamometer for geriatric and stroke patients

    OpenAIRE

    Hirano, Masahiro; Katoh, Munenori; Kawaguchi, Saori; Uemura, Tomomi

    2016-01-01

    [Purpose] This study aimed to verify the appropriate number of measurements and the intrarater reliabilities of shoulder joint horizontal adductor muscle strength measurements using a handheld dynamometer (HHD) for geriatric and stroke patients. [Subjects and Methods] The subjects were 40 inpatients, who were divided into two groups: 20 stroke patients in the stroke group (SG), and 20 geriatric patients in the no-stroke group (N-SG). Measurements were performed three times using an HHD with a...

  9. Breast surgical specimen radiographs: How reliable are they?

    International Nuclear Information System (INIS)

    Britton, P.D.; Sonoda, L.I.; Yamamoto, A.K.; Koo, B.; Soh, E.; Goud, A.

    2011-01-01

    Radiography of the excised surgical specimen following wire guided localisation of impalpable breast lesions is standard surgical practice. The aims of the study were to establish the reliability of the breast specimen radiograph (SR) in determining lesion excision and to determine whether the radiographic margin correlated with the histological margin. The clinical, imaging, SR and pathological details of 106 patients with a pre-operative diagnosis of breast cancer were retrospectively reviewed. The reliability of orientation was estimated and the appearance and distance from the mammographic abnormality to each radial margin were measured and correlated with surgical histological findings. The overall accuracy of the specimen radiograph in determining whether the mammographic lesion was present was 99%. The SR could be orientated 'very reliably' or 'reliably' in 80% of patients however in only 48% of patients did the closest margin on the SR correspond with the same nearest margin at final histology. A maximum measurement of 11 mm or more from the lesion to the specimen edge was associated with a 77% likelihood of having a clear final histological margin (taken as 5 mm or more) and if <11 mm a 58% chance of having involved final histological margins. There was however a wide overlap in the results with patients having an apparently wide SR margin but histologically involved margins and vice versa. The SR is reliable at determining whether the target lesion has been removed. The correlation of SR margin orientation and measurement with final histological measurement is however far less reliable.

  10. Validity and reliability of the 10-m walk test and the 6-min walk test in spinal cord injury patients.

    Science.gov (United States)

    Scivoletto, G; Tamburella, F; Laurenza, L; Foti, C; Ditunno, J F; Molinari, M

    2011-06-01

    The 10-m walk test (10MWT) and the 6-min walk test (6MWT) have been recommended for assessment of walking in spinal cord injury (SCI) patients. The study was designed on test-retest analysis of the 10MWT and 6MWT. The objective of this study was to assess validity/reliability of different methods of performing the tests. The study was set at an SCI unit of a rehabilitation hospital. A total of 37 patients; whose median age was 58.5 years (interquartile range 40-66, full range 19-77); median time since onset of SCI was 24 months (interquartile range 16.25-70.5, full range 6-109). Non-traumatic etiology in 20 out of 37 patients; level: 12C, 14T and 11L; American Spinal Injury Association Impairment Scale grade: 35D/2C. Assessment with the 10MWT (with or without dynamic start) and the 6MWT (short or long track) by two blinded raters to evaluate inter/intra-rater reliabilities. The 10MWT was performed in a median of 19 s (25th-75th interquartile range 13-28) with the dynamic start and of 18.4 s (25th-75th interquartile range 12.6-29.9) with the static start (P=0.092). The correlation between the results of the two methods was between 0.98 and 0.99. The inter- and intra-rater reliabilities were between 0.95 and 0.99 for both the methods. The 6MWT showed significant differences according to the track length: patients walked a median of 226.7 m (25th-75th interquartile range 123.2-319) on the longer track and of 187.6 m (25th-75th interquartile range 69.7-240.6) on the short one (P<0.001). The correlation between the results of the two methods was between 0.91 and 0.93. The inter- and intra-rater reliabilities were between 0.98 and 0.99. The 10MWT shows high inter/intra-rater reliability and shows comparable results with both dynamic and static start. The different testing conditions of the 6MWT (track/turns) results in significant differences that need standardization for use in future trials.

  11. Assignment of element and isotope factors

    International Nuclear Information System (INIS)

    Schneider, R.A.

    1984-01-01

    Element and isotope factors are assigned in the NICS internal accounting system at the Exxon Fuel Fabrication Facility on the basis of coded information included on the material transfer documents. This paper explains more fully the manner in which NICS assigns these factors

  12. Modeling Sensor Reliability in Fault Diagnosis Based on Evidence Theory

    Directory of Open Access Journals (Sweden)

    Kaijuan Yuan

    2016-01-01

    Full Text Available Sensor data fusion plays an important role in fault diagnosis. Dempster–Shafer (D-R evidence theory is widely used in fault diagnosis, since it is efficient to combine evidence from different sensors. However, under the situation where the evidence highly conflicts, it may obtain a counterintuitive result. To address the issue, a new method is proposed in this paper. Not only the statistic sensor reliability, but also the dynamic sensor reliability are taken into consideration. The evidence distance function and the belief entropy are combined to obtain the dynamic reliability of each sensor report. A weighted averaging method is adopted to modify the conflict evidence by assigning different weights to evidence according to sensor reliability. The proposed method has better performance in conflict management and fault diagnosis due to the fact that the information volume of each sensor report is taken into consideration. An application in fault diagnosis based on sensor fusion is illustrated to show the efficiency of the proposed method. The results show that the proposed method improves the accuracy of fault diagnosis from 81.19% to 89.48% compared to the existing methods.

  13. Inferential backbone assignment for sparse data

    International Nuclear Information System (INIS)

    Vitek, Olga; Bailey-Kellogg, Chris; Craig, Bruce; Vitek, Jan

    2006-01-01

    This paper develops an approach to protein backbone NMR assignment that effectively assigns large proteins while using limited sets of triple-resonance experiments. Our approach handles proteins with large fractions of missing data and many ambiguous pairs of pseudoresidues, and provides a statistical assessment of confidence in global and position-specific assignments. The approach is tested on an extensive set of experimental and synthetic data of up to 723 residues, with match tolerances of up to 0.5 ppm for C α and C β resonance types. The tests show that the approach is particularly helpful when data contain experimental noise and require large match tolerances. The keys to the approach are an empirical Bayesian probability model that rigorously accounts for uncertainty in the data at all stages in the analysis, and a hybrid stochastic tree-based search algorithm that effectively explores the large space of possible assignments

  14. Psychosocial Adjustment to Illness Scale: Factor structure, reliability, and validity assessment in a sample of Greek breast cancer patients.

    Science.gov (United States)

    Kolokotroni, Philippa; Anagnostopoulos, Fotios; Missitzis, Ioannis

    2017-07-01

    The study and measurement of psychosocial adjustment is important for evaluating patients' well-being, and assessing the illness's course, treatment's success, and patients' recovery. In this study, internal consistency reliability and construct validity of the Greek version of the Psychosocial Adjustment to Illness Scale-Self-Report (PAIS-SR) were examined. Demographic and psychosocial data were collected from a sample of 243 women with breast cancer, recruited from September 2011 to December 2012. With some exceptions in specific items, the original conceptually-derived PAIS-SR subscales emerged in a seven-factor solution. Social Environment, Job and Household Duties, and Psychological Distress accounted for more of the total variance than other subscales. PAIS-SR showed good internal consistency reliability, with Cronbach's alpha coefficients >0.62. Correlations of PAIS-SR domains with measures of quality of life and posttraumatic stress symptoms supported the convergent validity of the PAIS-SR and its significance for cancer research. The Greek version of the PAIS-SR has acceptable internal consistency reliability and construct validity, as well as satisfactory convergent validity. Results provide some suggestions for the development of programs to evaluate adjustment status and implement psychosocial interventions among breast cancer survivors.

  15. Reliability and validity of the 12-item WHODAS 2.0 in patients with Kashin-Beck disease.

    Science.gov (United States)

    Younus, Mohammad Imran; Wang, Di-Miao; Yu, Fang-Fang; Fang, Hua; Guo, Xiong

    2017-09-01

    The purpose of this study was to check the reliability and validity of the 12-item Chinese version of the World Health Organization Disability Assessment Schedule 2.0 (WHODAS 2.0) for the assessment of disability in patients with Kashin-Beck disease (KBD). We recruited 219 patients with KBD from the high-risk KBD area in the Shaanxi province, using stratified multistage random sampling. We assessed each patient using the Chinese version of the 12-item WHODAS 2.0 and the Western Ontario and McMaster Universities Index of Osteoarthritis (WOMAC). Statistical evaluations of the instruments consisted of Cronbach's alpha, intraclass correlation coefficient (ICC), confirmatory factor analysis (CFA), and Pearson's correlation coefficient. Cronbach's alpha and ICC for the six domains ranged from 0.704 to 0.906 and 0.690 to 0.852, respectively. A six-factor structure fits the data well (CFI = 0.967, TLI = 0.944, RMSEA = 0.08). Regarding convergent validity, the four domains of the 12-item WHODAS 2.0 (getting around, self-care, life activity, and participation) showed moderate-to-strong correlation for all three domains of the WOMAC (0.428 < |r| < 0.804). Regarding divergent validity, the two domains of the 12-item WHODAS 2.0 (understanding and communication, and getting along with people) showed weak correlation for the three domains of WOMAC (0.182 < |r| < 0.295). The Chinese version of 12-item WHODAS 2.0 questionnaire is a reliable and valid instrument when administered to KBD patients.

  16. Grant Peer Review: Improving Inter-Rater Reliability with Training.

    Science.gov (United States)

    Sattler, David N; McKnight, Patrick E; Naney, Linda; Mathis, Randy

    2015-01-01

    This study developed and evaluated a brief training program for grant reviewers that aimed to increase inter-rater reliability, rating scale knowledge, and effort to read the grant review criteria. Enhancing reviewer training may improve the reliability and accuracy of research grant proposal scoring and funding recommendations. Seventy-five Public Health professors from U.S. research universities watched the training video we produced and assigned scores to the National Institutes of Health scoring criteria proposal summary descriptions. For both novice and experienced reviewers, the training video increased scoring accuracy (the percentage of scores that reflect the true rating scale values), inter-rater reliability, and the amount of time reading the review criteria compared to the no video condition. The increase in reliability for experienced reviewers is notable because it is commonly assumed that reviewers--especially those with experience--have good understanding of the grant review rating scale. The findings suggest that both experienced and novice reviewers who had not received the type of training developed in this study may not have appropriate understanding of the definitions and meaning for each value of the rating scale and that experienced reviewers may overestimate their knowledge of the rating scale. The results underscore the benefits of and need for specialized peer reviewer training.

  17. Cross-Cultural Translation, Adaptation and Reliability of the Danish M. D. Andeson Dysphagia Inventory (MDADI) in Patients with Head and Neck Cancer

    DEFF Research Database (Denmark)

    Hajdú, Sara Fredslund; Plaschke, Christina Caroline; Johansen, Christoffer

    2017-01-01

    The objectives were to translate and culturally adapt the M.D. Anderson Dysphagia Inventory (MDADI) into Danish and subsequently test the reliability of the Danish version. The MDADI was translated into Danish and cross culturally adapted through cognitive interviews. The final version was test...... patients were interviewed on the comprehensibility of the Danish MDADI, and all found the questionnaire meaningful, easy to understand, non-offensive and to include relevant aspects of dysphagia related to HNC. Sixty-four patients were included in the test-retest study. Especially, one item....... The Danish MDADI is reliable in terms of internal consistency and test-retest reproducibility and can be used in assessing the health-related quality of life in head and neck cancer patients with dysphagia....

  18. Improving fMRI reliability in presurgical mapping for brain tumours.

    Science.gov (United States)

    Stevens, M Tynan R; Clarke, David B; Stroink, Gerhard; Beyea, Steven D; D'Arcy, Ryan Cn

    2016-03-01

    Functional MRI (fMRI) is becoming increasingly integrated into clinical practice for presurgical mapping. Current efforts are focused on validating data quality, with reliability being a major factor. In this paper, we demonstrate the utility of a recently developed approach that uses receiver operating characteristic-reliability (ROC-r) to: (1) identify reliable versus unreliable data sets; (2) automatically select processing options to enhance data quality; and (3) automatically select individualised thresholds for activation maps. Presurgical fMRI was conducted in 16 patients undergoing surgical treatment for brain tumours. Within-session test-retest fMRI was conducted, and ROC-reliability of the patient group was compared to a previous healthy control cohort. Individually optimised preprocessing pipelines were determined to improve reliability. Spatial correspondence was assessed by comparing the fMRI results to intraoperative cortical stimulation mapping, in terms of the distance to the nearest active fMRI voxel. The average ROC-r reliability for the patients was 0.58±0.03, as compared to 0.72±0.02 in healthy controls. For the patient group, this increased significantly to 0.65±0.02 by adopting optimised preprocessing pipelines. Co-localisation of the fMRI maps with cortical stimulation was significantly better for more reliable versus less reliable data sets (8.3±0.9 vs 29±3 mm, respectively). We demonstrated ROC-r analysis for identifying reliable fMRI data sets, choosing optimal postprocessing pipelines, and selecting patient-specific thresholds. Data sets with higher reliability also showed closer spatial correspondence to cortical stimulation. ROC-r can thus identify poor fMRI data at time of scanning, allowing for repeat scans when necessary. ROC-r analysis provides optimised and automated fMRI processing for improved presurgical mapping. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence

  19. Reliability and Validity of Beliefs about Substance Use (BSU Questionnaire in Alcohol Dependent Patients.

    Directory of Open Access Journals (Sweden)

    Selçuk ASLAN

    2012-12-01

    Results: Mean age of the addicted patients, healthy controls and social drinkers were 42,3± 7,0, 33,5± 9,9 and 33,2± 8,9, respectively. In patient group, mean BSU score was 46,4 ± 21,2. For alcohol addicts, internal reliability of BSU was foundto be adequate (Cronbach alfa=0.91 and item-total score correlations were between 0.33 and 0.69. Basic component analysis showed one basic factor. A positive correlation has been found between BSU and CBQ, and ATQ scores. No correlations have been found between total and subscale scores of DAS and total scores of CIWA, BAI and BSU. In evaluation of validity, BSU mean scores of alcohol addicts were found to be significantly higher than healthy controls and social drinkers. Conclusion: Our findings support that Turkish version of BSU is an adequate tool that can be used to evaluate alcohol addicted patients` cognitive believes about alcohol use. [JCBPR 2012; 1(3.000: 162-170

  20. "The group facilitates everything": meanings patients with type 2 diabetes mellitus assigned to health education groups.

    Science.gov (United States)

    de Melo, Lucas Pereira; de Campos, Edemilson Antunes

    2014-01-01

    to interpret the meanings patients with type 2 diabetes mellitus assign to health education groups. ethnographic study conducted with Hyperdia groups of a healthcare unit with 26 informants, with type 2 diabetes mellitus, and having participated in the groups for at least three years. Participant observation, social characterization, discussion groups and semi-structured interviews were used to collect data. Data were analyzed through the thematic coding technique. four thematic categories emerged: ease of access to the service and healthcare workers; guidance on diabetes; participation in groups and the experience of diabetes; and sharing knowledge and experiences. The most relevant aspect of this study is the social use the informants in relation to the Hyperdia groups under study. the studied groups are agents producing senses and meanings concerning the process of becoming ill and the means of social navigation within the official health system. We expect this study to contribute to the actions of healthcare workers coordinating these groups given the observation of the cultural universe of these individuals seeking professional care in the various public health care services.

  1. Inter-tester reliability of a new diagnostic classification system for patients with non-specific low back pain

    DEFF Research Database (Denmark)

    Petersen, Tom Erik; Olsen, Steen; Laslett, Mark

    2004-01-01

    Most patients referred to physiotherapy with low back pain are without a precise medical diagnosis. Identification of subgroups of non-specific low back pain patients may improve clinical outcomes and research efficiency. A pathoanatomic classification system has been developed, classifying...... modest level of total agreement (39%) for the system as a whole might indicate that the utility of the system for general screening purposes is limited, compared with the utility in identification of particular syndromes. Due to low prevalence of positive findings in some of the syndromes, future work...... should focus on testing reliability on a larger sample of patients, and testing of validity and feasibility of the system....

  2. Reliability, validity, and responsiveness of the Western Ontario and McMaster Universities Osteoarthritis Index for elderly patients with a femoral neck fracture

    NARCIS (Netherlands)

    P.T.P.W. Burgers (Paul); R.W. Poolman (Rudolf); T.M. van Bakel (Theodorus); W.E. Tuinebreijer (Wim); S.M. Zielinski (Stephanie); M. Bhandari (Mohit); P. Patka (Peter); E.M.M. van Lieshout (Esther)

    2015-01-01

    markdownabstractBackground: The Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) has been extensively evaluated in groups of patients with osteoarthritis, yet not in patients with a femoral neck fracture. This study aimed to determine the reliability, construct validity, and

  3. Reliability issues in PACS

    Science.gov (United States)

    Taira, Ricky K.; Chan, Kelby K.; Stewart, Brent K.; Weinberg, Wolfram S.

    1991-07-01

    Reliability is an increasing concern when moving PACS from the experimental laboratory to the clinical environment. Any system downtime may seriously affect patient care. The authors report on the several classes of errors encountered during the pre-clinical release of the PACS during the past several months and present the solutions implemented to handle them. The reliability issues discussed include: (1) environmental precautions, (2) database backups, (3) monitor routines of critical resources and processes, (4) hardware redundancy (networks, archives), and (5) development of a PACS quality control program.

  4. Translation, cultural adaptation assessment, and both validity and reliability testing of the kidney disease quality of life - short form version 1.3 for use with Iranian patients

    DEFF Research Database (Denmark)

    Pakpour, Amir; Yekaninejad, Mirsaeed; Mølsted, Stig

    2011-01-01

    AIM: The aims of the study were to translate the Kidney Disease Quality of Life--Short Form version 1.3 (KDQOL-SF ver. 1.3) questionnaire into Iranian (Farsi), and to then assess it in terms of validity and reliability on Iranian patients. METHODS: The questionnaire was first translated into Farsi...... a larger group (212 patients with end-stage renal disease on haemodialysis). Afterwards, reliability was estimated by internal consistency, and validity was assessed using known group comparisons and constructs for the patient group as a whole. Finally, the factor structure of the questionnaire...... be summarized into an 11 factor structure that jointly accounted for 79.81% of the variance. CONCLUSION: The Iranian version of the KDQOL-SF questionnaire is both highly reliable and valid for use with Iranian patients on haemodialysis....

  5. Validity and Reliability of the MacNew Heart Disease Health-Related Quality of Life Questionnaire in Patients with Heart Failure: The Persian Version

    Directory of Open Access Journals (Sweden)

    Mohammad Abbasi

    2017-12-01

    Full Text Available Background: Heart failure due to changes in the lungs, circulation, and skeletal muscle adversely influences the quality of life. Objectives: The objective of the present study is to assess the reliability and validity of the Persian version of the MacNew in patients with heart failure. Patients and Methods: The 200 Iranian patients who referred to Shahid Beheshti hospital in Qom were recruited by convenience sampling. All the patients filled out the MacNew HRQL questionnaire, the hospital anxiety and depression scale (HADS, the Short Form- 36 and socio-demographic and clinical characteristics. The reliability of the MacNew was assessed by internal consistency and test-retest reliability. Construct validity was assessed by factor analysis, convergent validity and discriminant validity. Discriminant validity of MacNew was assessed by the known-groups approach. All analyses were done through SPSS, version 20, and level of significance was considered at P < 0.05. Results: The mean MacNew Global score was 3.6 ± 0.82. Our results demonstrated that internal consistency (α = 0.94 and reproducibility (ICC = 0.84 of the Persian version of the MacNew were confirmed. The Factor analysis confirmed three factors as the original MacNew. Convergent and divergent validity of the MacNew was confirmed by its correlation pattern with physical and mental components of the SF-36. Discriminative validity was confirmed statistically and clinically for the differences in the MacNew scores on the Global scale and each subscale between Iranian patients with and without anxiety and depression. Conclusions: The Persian version of the MacNew HRQL questionnaire can be applied as a reliable and valid tool in the clinical research for Iranian patients with heart failure.

  6. Strength and Pain Threshold Handheld Dynamometry Test Reliability in Patellofemoral Pain.

    Science.gov (United States)

    van der Heijden, R A; Vollebregt, T; Bierma-Zeinstra, S M A; van Middelkoop, M

    2015-12-01

    Patellofemoral pain syndrome (PFPS), characterized by peri- and retropatellar pain, is a common disorder in young, active people. The etiology is unclear; however, quadriceps strength seems to be a contributing factor, and sensitization might play a role. The study purpose is determining the inter-rater reliability of handheld dynamometry to test both quadriceps strength and pressure pain threshold (PPT), a measure for sensitization, in patients with PFPS. This cross-sectional case-control study comprises 3 quadriceps strength and one PPT measurements performed by 2 independent investigators in 22 PFPS patients and 16 matched controls. Inter-rater reliability was analyzed using intraclass correlation coefficients (ICC) and Bland-Altman plots. Inter-rater reliability of quadriceps strength testing was fair to good in PFPS patients (ICC=0.72) and controls (ICC=0.63). Bland-Altman plots showed an increased difference between assessors when average quadriceps strength values exceeded 250 N. Inter-rater reliability of PPT was excellent in patients (ICC=0.79) and fair to good in controls (ICC=0.52). Handheld dynamometry seems to be a reliable method to test both quadriceps strength and PPT in PFPS patients. Inter-rater reliability was higher in PFPS patients compared to control subjects. With regard to quadriceps testing, a higher variance between assessors occurs when quadriceps strength increases. © Georg Thieme Verlag KG Stuttgart · New York.

  7. Psychometric validation and reliability analysis of a Spanish version of the patient satisfaction with cancer-related care measure: a patient navigation research program study.

    Science.gov (United States)

    Jean-Pierre, Pascal; Fiscella, Kevin; Winters, Paul C; Paskett, Electra; Wells, Kristen; Battaglia, Tracy

    2012-09-01

    Patient satisfaction (PS), a key measure of quality of cancer care, is a core study outcome of the multi-site National Cancer Institute-funded Patient Navigation Research Program. Despite large numbers of underserved monolingual Spanish speakers (MSS) residing in USA, there is no validated Spanish measure of PS that spans the whole spectrum of cancer-related care. The present study reports on the validation of the Patient Satisfaction with Cancer Care (PSCC) measure for Spanish (PSCC-Sp) speakers receiving diagnostic and therapeutic cancer-related care. Original PSCC items were professionally translated and back translated to ensure cultural appropriateness, meaningfulness, and equivalence. Then, the resulting 18-item PSCC-Sp measure was administered to 285 MSS. We evaluated latent structure and internal consistency of the PSCC-Sp using principal components analysis (PCA) and Cronbach coefficient alpha (α). We used correlation analyses to demonstrate divergence and convergence of the PSCC-Sp with a Spanish version of the Patient Satisfaction with Interpersonal Relationship with Navigator (PSN-I-Sp) measure and patients' demographics. The PCA revealed a coherent set of items that explicates 47% of the variance in PS. Reliability assessment demonstrated that the PSCC-Sp had high internal consistency (α = 0.92). The PSCC-Sp demonstrated good face validity and convergent and divergent validities as indicated by moderate correlations with the PSN-I-Sp (p = 0.003) and nonsignificant correlations with marital status and household income (all p(s) > 0.05). The PSCC-Sp is a valid and reliable measure of PS and should be tested in other MSS populations.

  8. Feasibility and reliability of the modified berg balance scale in persons with severe intellectual and visual disabilities

    NARCIS (Netherlands)

    Waninge, Aly; van Wijck, R.; Steenbergen, B.; van der Schans, Cees

    2011-01-01

    Background: The purpose of this study was to determine the feasibility and reliability of the modified Berg Balance Scale (mBBS) in persons with severe intellectual and visual disabilities (severe multiple disabilities, SMD) assigned Gross Motor Function Classification System (GMFCS) grades I and

  9. Toward efficient task assignment and motion planning for large-scale underwater missions

    Directory of Open Access Journals (Sweden)

    Somaiyeh MahmoudZadeh

    2016-10-01

    Full Text Available An autonomous underwater vehicle needs to possess a certain degree of autonomy for any particular underwater mission to fulfil the mission objectives successfully and ensure its safety in all stages of the mission in a large-scale operating field. In this article, a novel combinatorial conflict-free task assignment strategy, consisting of an interactive engagement of a local path planner and an adaptive global route planner, is introduced. The method takes advantage of the heuristic search potency of the particle swarm optimization algorithm to address the discrete nature of routing-task assignment approach and the complexity of nondeterministic polynomial-time-hard path planning problem. The proposed hybrid method is highly efficient as a consequence of its reactive guidance framework that guarantees successful completion of missions particularly in cluttered environments. To examine the performance of the method in a context of mission productivity, mission time management, and vehicle safety, a series of simulation studies are undertaken. The results of simulations declare that the proposed method is reliable and robust, particularly in dealing with uncertainties, and it can significantly enhance the level of a vehicle’s autonomy by relying on its reactive nature and capability of providing fast feasible solutions.

  10. The validity and reliability of the Socioeconomic Status Instrument for assessing prostate cancer patients.

    Science.gov (United States)

    Cyrus-David, Mfon

    2010-08-01

    Because of the lack of consistency in the associations of the socioeconomic status (SES) of prostate cancer (PC) patients from diverse racial and ethnic backgrounds with PC health outcomes, I created the Socioeconomic Status Instrument (SESI) from the Demographic and Health Access components of the Behavioral Risk Factor Surveillance System 2004 Questionnaires and the socioeconomic indices of the subjects' residential counties to better assess the SES of PC patients. The SESI was tested on 220 consecutive subjects with pathologically confirmed PC at the Veterans Affairs Medical Center in Houston, TX. A team that included an epidemiologist, a validation statistician/health services research scientist, and PC survivors assessed the content validity of the SESI. The construct validity of the SESI was assessed with factor analysis by extracting and analyzing 5 principal components based on the subjects' individual responses on the assessment: county socioeconomic characteristics, individual socioeconomic characteristics, financial distress, increased domestic burden with limited earnings, and affluence. The internal consistency reliability of the SESI was assessed with Cronbach's alpha coefficients. Based on the reviews of the SESI, all of the initial 10 items were retained. The correlations between individual responses on the SESI were similar to the results of previous studies. The 5 principal components that I assessed accounted for 71.5% of the variance. Factor loadings ranged from 0.66 to 0.98 and communalities ranged from 0.55 to 0.94. County socioeconomic characteristics accounted for 22.6% of the variance, whereas individual socioeconomic characteristics accounted for 14.6% of the variance. The overall Cronbach's alpha coefficient was 0.78. The SESI is valid and reliable. Accurate measurements of the SES of PC patients would provide better guidance for future research and care deliveries.

  11. Validity and reliability problems with patient global as a component of the ACR/EULAR remission criteria as used in clinical practice.

    Science.gov (United States)

    Masri, Karim R; Shaver, Timothy S; Shahouri, Shadi H; Wang, Shirley; Anderson, James D; Busch, Ruth E; Michaud, Kaleb; Mikuls, Ted R; Caplan, Liron; Wolfe, Frederick

    2012-06-01

    To investigate what factors influence patient global health assessment (PtGlobal), and how those factors and the reliability of PtGlobal affect the rate, reliability, and validity of recently published American College of Rheumatology/European League Against Rheumatism (ACR/EULAR) rheumatoid arthritis (RA) remission criteria when used in clinical practice. We examined consecutive patients with RA in clinical practice and identified 77 who met ACR/EULAR joint criteria for remission (≤ 1 swollen joint and ≤ 1 tender joint). We evaluated factors associated with a PtGlobal > 1, because a PtGlobal ≤ 1 defined ACR/EULAR remission in this group of patients who had already met ACR/EULAR joint criteria. Of the 77 patients examined, only 17 (22.1%) had PtGlobal ≤ 1 and thus fully satisfied ACR/EULAR criteria. A large proportion of patients not in remission by ACR/EULAR criteria had high PtGlobal related to noninflammatory issues, including low back pain, fatigue, and functional limitations, and a number of patients clustered in the range of PtGlobal > 1 and ≤ 2. However, the minimal detectable difference for PtGlobal was 2.3. In addition, compared with a PtGlobal severity score, a PtGlobal activity score was 3.3% less likely to be abnormal (> 1). Noninflammatory factors contribute to the level of PtGlobal and result in the exclusion of many patients who would otherwise be in "true" remission according to the ACR/EULAR definition. Reliability problems associated with PtGlobal can also result in misclassification, and may explain the observation of low longterm remission rates in RA. As currently constituted, the use of the ACR/EULAR remission criteria in clinical practice appears to be problematic.

  12. [Reliability of the PROFUND index to predict 4-year mortality in polypathological patients].

    Science.gov (United States)

    Díez-Manglano, Jesús; Del Corral Beamonte, Esther; Ramos Ibáñez, Rosa; Lambán Aranda, María Pilar; Toyas Miazza, Carla; Rodero Roldán, María Del Mar; Ortiz Domingo, Concepción; Munilla López, Eulalia; de Escalante Yangüela, Begoña

    2016-09-16

    To determine the usefullness of the PROFUND index to assess the risk of global death after 4 years in polypathological patients. Multicenter prospective cohort (Internal Medicine and Geriatrics) study. Polypathological patients admitted between March 1st and June 30th 2011 were included. For each patient, data concerning age, sex, living at home or in a nursing residence, polypathology categories, Charlson, Barthel and Lawton-Brody indexes, Pfeiffer questionnaire, socio-familial Gijon scale, delirium, number of drugs, hemoglobin and creatinine values were gathered, and the PROFUND index was calculated. The follow-up lasted 4 years. We included 441 patients, 324 from Internal Medicine and 117 from Geriatrics, with a mean age of 80.9 (8.7) years. Of them, 245 (55.6%) were women. Heart (62.7%), neurological (41.4%) and respiratory (37.3%) diseases were the most frequent. Geriatrics inpatients were older and more dependants and presented greater cognitive deterioration. After 4 years, 335 (76%) patients died. Mortality was associated with age, dyspnoea, Barthel index<60, delirium, advanced neoplasia and≥4 admissions in the last year. The area under the curve of the PROFUND index was 0.748, 95% CI 0.689-0.806, P<.001 in Internal Medicine and 0.517, 95% CI 0.369-0.666, P=.818 in Geriatrics patients, respectively. The PROFUND index is a reliable tool for predicting long-term global mortality in polypathological patients from Internal Medicine but not from Geriatrics departments. Copyright © 2016 Elsevier España, S.L.U. All rights reserved.

  13. COMPI Fertility Problem Stress Scales is a brief, valid and reliable tool for assessing stress in patients seeking treatment

    DEFF Research Database (Denmark)

    Sobral, Maria P.; Costa, Maria E.; Schmidt, Lone

    2017-01-01

    comparability of fertility-related stress across genders and countries. STUDY DESIGN SIZE, DURATION Cross-sectional study. First, we tested the structure of the COMPI-FPSS. Then, reliability and validity (convergent and discriminant) were examined for the final model. Finally, measurement invariance both across...... genders and cultures was tested. PARTICIPANTS/MATERIALS, SETTING, METHODS Our final sample had 3923 fertility patients (1691 men and 2232 women) recruited in clinical settings from seven different countries: Denmark, China, Croatia, Germany, Greece, Hungary and Sweden. Participants had a mean age of 34......STUDY QUESTION Are the Copenhagen Multi‐Centre Psychosocial Infertility research program Fertility Problem Stress Scales (COMPI-FPSS) a reliable and valid measure across gender and culture? SUMMARY ANSWER The COMPI-FPSS is a valid and reliable measure, presenting excellent or good fit...

  14. Reliability, validity, and responsiveness of the Western Ontario and McMaster Universities Osteoarthritis Index for elderly patients with a femoral neck fracture

    NARCIS (Netherlands)

    Burgers, P.T.; Poolman, R.W.; Bakel, T.M. Van; Tuinebreijer, W.E.; Zielinski, S.M.; Bhandari, M.; Patka, P.; Lieshout, E.M. van; Kampen, A. van; Biert, J.; Vugt, A.B. van; Edwards, M.J.R.; Blokhuis, T.J.; Frolke, J.P.; Geeraedts, L.M.G.; Gardeniers, J.W.M.; Tan, E.C.T.H.; Poelhekke, L.M.S.J.; Waal Malefijt, M.C. de; Schreurs, B.W.; et al.,

    2015-01-01

    BACKGROUND: The Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) has been extensively evaluated in groups of patients with osteoarthritis, yet not in patients with a femoral neck fracture. This study aimed to determine the reliability, construct validity, and responsiveness of

  15. Reliability, Validity, and Responsiveness of the Western Ontario and McMaster Universities Osteoarthritis Index for Elderly Patients with a Femoral Neck Fracture

    NARCIS (Netherlands)

    Burgers, Paul T. P. W.; Poolman, Rudolf W.; van Bakel, Theodorus M. J.; Tuinebreijer, Wim E.; Zielinski, Stephanie M.; Bhandari, Mohit; Patka, Peter; van Lieshout, Esther M. M.; Devereaux, P. J.; Guyatt, Gordon H.; Einhorn, Thomas A.; Thabane, Lehana; Schemitsch, Emil H.; Koval, Kenneth J.; Frihagen, Frede; Tetsworth, Kevin; Guerra-Farfan, Ernesto; Walter, Stephen D.; Sprague, Sheila; Swinton, Marilyn; Scott, Taryn; McKay, Paula; Madden, Kim; Heels-Ansdell, Diane; Buckingham, Lisa; Duraikannan, Aravin; Silva, Heather; Heetveld, Martin J.; Burgers, T. P. W.; Zura, Robert D.; Avram, Victoria; Eygendaal, Denise; Krips, Rover; Raven, Eric E. J.; Haverlag, Robert; Mutsaerts, Eduard L. A. R.; Haverkamp, Daniel; van den Bekerom, Michel P. J.; Beimers, Lijkele; de Vries, Jasper; Zurcher, Arthur W.; Bulstra, Gythe H.; Campo, Martin M.; Somford, Mathijs P.; Schep, Niels W. L.; Festen, Sebastiaan; Geeraedts, Leo M. G.; Peters, Rolf; Goslings, J. Carel; Ponsen, Kees Jan

    2015-01-01

    Background: The Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) has been extensively evaluated in groups of patients with osteoarthritis, yet not in patients with a femoral neck fracture. This study aimed to determine the reliability, construct validity, and responsiveness of

  16. The Korean Version of the Cognitive Assessment Scale for Stroke Patients (K-CASP): A Reliability and Validity Study.

    Science.gov (United States)

    Park, Kwon-Hee; Lee, Hee-Won; Park, Kee-Boem; Lee, Jin-Youn; Cho, Ah-Ra; Oh, Hyun-Mi; Park, Joo Hyun

    2017-06-01

    To develop the Korean version of the Cognitive Assessment Scale for Stroke Patients (K-CASP) and to evaluate the test reliability and validity of the K-CASP in stroke patients. The original CASP was translated into Korean, back-translated into English, then reviewed and compared with the original version. Thirty-three stroke patients were assessed independently by two examiners using the K-CASP twice, with a one-day interval, for a total of four test results. To evaluate the reliability of the K-CASP, intra-class correlation coefficients were used. Pearson correlations were calculated and simple regression analyses performed with the Korean version of Mini-Mental State Examination (K-MMSE) and the aphasia quotient (AQ) to assess the validity. The mean score was 24.42±9.47 (total score 36) for the K-CASP and 21.50±7.01 (total score 30) for the K-MMSE. The inter-rater correlation coefficients of the K-CASP were 0.992 on the first day and 0.995 on the second day. The intra-rater correlation coefficients of the K-CASP were 0.997 for examiner 1 and 0.996 for examiner 2. In the Pearson correlation analysis, the K-CASP score significantly correlated with the K-MMSE score (r=0.825, preliable and valid instrument for cognitive dysfunction screening in post-stroke patients. It is more applicable than other cognitive assessment tools in stroke patients with aphasia.

  17. Clinical Functional Capacity Testing in Patients With Facioscapulohumeral Muscular Dystrophy: Construct Validity and Interrater Reliability of Antigravity Tests.

    Science.gov (United States)

    Rijken, Noortje H; van Engelen, Baziel G; Weerdesteyn, Vivian; Geurts, Alexander C

    2015-12-01

    To evaluate the construct validity and interrater reliability of 4 simple antigravity tests in a small group of patients with facioscapulohumeral muscular dystrophy (FSHD). Case-control study. University medical center. Patients with various severity levels of FSHD (n=9) and healthy control subjects (n=10) were included (N=19). Not applicable. A 4-point ordinal scale was designed to grade performance on the following 4 antigravity tests: sit to stance, stance to sit, step up, and step down. In addition, the 6-minute walk test, 10-m walking test, Berg Balance Scale, and timed Up and Go test were administered as conventional tests. Construct validity was determined by linear regression analysis using the Clinical Severity Score (CSS) as the dependent variable. Interrater agreement was tested using a κ analysis. Patients with FSHD performed worse on all 4 antigravity tests compared with the controls. Stronger correlations were found within than between test categories (antigravity vs conventional). The antigravity tests revealed the highest explained variance with regard to the CSS (R(2)=.86, P=.014). Interrater agreement was generally good. The results of this exploratory study support the construct validity and interrater reliability of the proposed antigravity tests for the assessment of functional capacity in patients with FSHD taking into account the use of compensatory strategies. Future research should further validate these results in a larger sample of patients with FSHD. Copyright © 2015 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  18. 32 CFR 884.2 - Assigned responsibilities.

    Science.gov (United States)

    2010-07-01

    ... OF PERSONNEL TO UNITED STATES CIVILIAN AUTHORITIES FOR TRIAL § 884.2 Assigned responsibilities. (a... 32 National Defense 6 2010-07-01 2010-07-01 false Assigned responsibilities. 884.2 Section 884.2... requests for return of members to the United States for delivery to civilian authorities when the request...

  19. Reliability evaluation of a natural circulation system

    International Nuclear Information System (INIS)

    Jafari, Jalil; D'Auria, Francesco; Kazeminejad, Hossein; Davilu, Hadi

    2003-01-01

    This paper discusses a reliability study performed with reference to a passive thermohydraulic natural circulation (NC) system, named TTL-1. A methodology based on probabilistic techniques has been applied with the main purpose to optimize the system design. The obtained results have been adopted to estimate the thermal-hydraulic reliability (TH-R) of the same system. A total of 29 relevant parameters (including nominal values and plausible ranges of variations) affecting the design and the NC performance of the TTL-1 loop are identified and a probability of occurrence is assigned for each value based on expert judgment. Following procedures established for the uncertainty evaluation of thermal-hydraulic system codes results, 137 system configurations have been selected and each configuration has been analyzed via the Relap5 best-estimate code. The reference system configuration and the failure criteria derived from the 'mission' of the passive system are adopted for the evaluation of the system TH-R. Four different definitions of a less-than-unity 'reliability-values' (where unity represents the maximum achievable reliability) are proposed for the performance of the selected passive system. This is normally considered fully reliable, i.e. reliability-value equal one, in typical Probabilistic Safety Assessment (PSA) applications in nuclear reactor safety. The two 'point' TH-R values for the considered NC system were found equal to 0.70 and 0.85, i.e. values comparable with the reliability of a pump installed in an 'equivalent' forced circulation (active) system having the same 'mission'. The design optimization study was completed by a regression analysis addressing the output of the 137 calculations: heat losses, undetected leakage, loop length, riser diameter, and equivalent diameter of the test section have been found as the most important parameters bringing to the optimal system design and affecting the TH-R. As added values for this work, the comparison has

  20. Reliability of the Cooking Task in adults with acquired brain injury.

    Science.gov (United States)

    Poncet, Frédérique; Swaine, Bonnie; Taillefer, Chantal; Lamoureux, Julie; Pradat-Diehl, Pascale; Chevignard, Mathilde

    2015-01-01

    Acquired brain injury (ABI) often leads to deficits in executive functioning (EF) responsible for severe and long-standing disabilities in daily life activities. The Cooking Task is an ecological and valid test of EF involving multi-tasking in a real environment. Given its complex scoring system, it is important to establish the tool's reliability. The objective of the study was to examine the reliability of the Cooking Task (internal consistency, inter-rater and test-retest reliability). A total of 160 patients with ABI (113 men, mean age 37 years, SD = 14.3) were tested using the Cooking Task. For test-retest reliability, patients were assessed by the same rater on two occasions (mean interval 11 days) while two raters independently and simultaneously observed and scored patients' performances to estimate inter-rater reliability. Internal consistency was high for the global scale (Cronbach α = .74). Inter-rater reliability (n = 66) for total errors was also high (ICC = .93), however the test-retest reliability (n = 11) was poor (ICC = .36). In general the Cooking Task appears to be a reliable tool. The low test-retest results were expected given the importance of EF in the performance of novel tasks.

  1. Personnel dose assignment practices

    International Nuclear Information System (INIS)

    Fix, J.J.

    1993-04-01

    Implementation of DOE N 5480.6 Radiological Control Manual Article 511(3) requirements, to minimize the assignment of personnel dosimeters, should be done only under a broader context ensuring that capabilities are in place to monitor and record personnel exposure both for compliance and for potential litigation. As noted in NCRP Report No. 114, personnel dosimetry programs are conducted to meet four major objectives: radiation safety program control and evaluation; regulatory compliance; epidemiological research; and litigation. A change to Article 511(3) is proposed that would require that minimizing the assignment of personnel dosimeters take place only following full evaluation of overall capabilities (e.g., access control, area dosimetry, etc.) to meet the NCRP objectives

  2. Reliability of an e-PRO Tool of EORTC QLQ-C30 for Measurement of Health-Related Quality of Life in Patients With Breast Cancer: Prospective Randomized Trial.

    Science.gov (United States)

    Wallwiener, Markus; Matthies, Lina; Simoes, Elisabeth; Keilmann, Lucia; Hartkopf, Andreas D; Sokolov, Alexander N; Walter, Christina B; Sickenberger, Nina; Wallwiener, Stephanie; Feisst, Manuel; Gass, Paul; Fasching, Peter A; Lux, Michael P; Wallwiener, Diethelm; Taran, Florin-Andrei; Rom, Joachim; Schneeweiss, Andreas; Graf, Joachim; Brucker, Sara Y

    2017-09-14

    Breast cancer represents the most common malignant disease in women worldwide. As currently systematic palliative treatment only has a limited effect on survival rates, the concept of health-related quality of life (HRQoL) is gaining more and more importance in the therapy setting of metastatic breast cancer. One of the major patient-reported outcomes (PROs) for measuring HRQoL in patients with breast cancer is provided by the European Organization for Research and Treatment of Cancer (EORTC). Currently, paper-based surveys still predominate, as only a few reliable and validated electronic-based questionnaires are available. Facing the possibilities associated with evolving digitalization in medicine, validation of electronic versions of well-established PRO is essential in order to contribute to comprehensive and holistic oncological care and to ensure high quality in cancer research. The aim of this study was to analyze the reliability of a tablet-based measuring application for EORTC QLQ-C30 in German language in patients with adjuvant and (curative) metastatic breast cancer. Paper- and tablet-based questionnaires were completed by a total of 106 female patients with adjuvant and metastatic breast cancer recruited as part of the e-PROCOM study. All patients were required to complete the electronic- (e-PRO) and paper-based versions of the HRQoL EORTC QLQ-C30 questionnaire. A frequency analysis was performed to determine descriptive sociodemographic characteristics. Both dimensions of reliability (parallel forms reliability [Wilcoxon test] and test of internal consistency [Spearman rho and agreement rates for single items, Pearson correlation and Kendall tau for each scale]) were analyzed. High correlations were shown for both dimensions of reliability (parallel forms reliability and internal consistency) in the patient's response behavior between paper- and electronic-based questionnaires. Regarding the test of parallel forms reliability, no significant

  3. Main-chain-directed strategy for the assignment of 1H NMR spectra of proteins

    International Nuclear Information System (INIS)

    Englander, S.W.; Wand, A.J.

    1987-01-01

    A strategy for assigning the resonances in two-dimensional (2D) NMR spectra of proteins is described. The method emphasizes the analysis of through-space relationships between protons by use of the two-dimensional nuclear Overhauser effect (NOE) experiment. NOE patterns used in the algorithm were derived from a statistical analysis of the combinations of short proton-proton distances observed in the high-resolution crystal structures of 21 proteins. One starts with a search for authentic main-chain NH-C/sub α/H-C/sub β/H J-coupled units, which can be found with high reliability. The many main-chain units of a protein are then placed in their proper juxtaposition by recognition of predefined NOE connectivity patterns. To discover these connectivities, the 2D NOE spectrum is examined, in a prescribed order, for the distinct NOE patterns characteristic of helices, sheets, turns, and extended chain. Finally, the recognition of a few amino acid side-chain types places the discovered secondary structure elements within the polypeptide sequences. Unlike the sequential assignment approach, the main-chain-directed strategy does not rely on the difficult task of recognizing many side-chain spin systems in J-correlated spectra, the assignment process is not in general sequential with the polypeptide chain, and the prescribed connectivity patterns are cyclic rather than linear. The latter characteristic avoids ambiguous branch points in the analysis and imposed an internally confirmatory property on each forward step

  4. Computational Aspects of Assigning Agents to a Line

    DEFF Research Database (Denmark)

    Aziz, Haris; Hougaard, Jens Leth; Moreno-Ternero, Juan D.

    2017-01-01

    -egalitarian assignments. The approach relies on an algorithm which is shown to be faster than general purpose algorithms for the assignment problem. We also extend the approach to probabilistic assignments and explore the computational features of existing, as well as new, methods for this setting....

  5. Computational aspects of assigning agents to a line

    DEFF Research Database (Denmark)

    Aziz, Haris; Hougaard, Jens Leth; Moreno-Ternero, Juan D.

    2017-01-01

    -egalitarian assignments. The approach relies on an algorithm which is shown to be faster than general purpose algorithms for the assignment problem. We also extend the approach to probabilistic assignments and explore the computational features of existing, as well as new, methods for this setting....

  6. The Turkish adaptation of scale to measure patient perceptions of the quality of nursing care and related hospital services: A validity and reliability study.

    Science.gov (United States)

    Oren, Besey; Zengin, Neriman; Yildiz, Nebahat

    2016-01-01

    This study aimed to test the validity and reliability of a version of the tool developed in Sri Lanka in 2011 to assess patient perceptions of the quality of nursing care and related hospital services created for use with Turkish patients. This methodological study was conducted between November 2013 and November 2014 after obtaining ethical approval and organizational permission. Data was collected during discharge from 180 adult patients who were hospitalized for at least 3 days at a medical school hospital located in Istanbul. After language validation, validity and reliability analyses of the scale were conducted. Content validity, content validity index (CVI), construct validity, and exploratory factor analysis were assessed and examined, and reliability was tested using the Cronbach's alpha coefficient and item-total correlations. Mean CVI was found to be 0.95, which is above expected value. Exploratory factor analysis revealed 4 factors with eigenvalues above 1, which explained 82.4% of total variance in the Turkish version of the tool to measure patient perceptions of nursing care and other hospital services. Factor loading for each item was ≥.40. Cronbach's alpha coefficient of sub-dimensions and total scale were found to be 0.84-0.98 and 0.98, respectively. Item-total correlations ranged from 0.56 to 0.83 for the entire group, which was above expected values. The Turkish version of the scale to assess patient perceptions of the quality of nursing care and related hospital services, which comprised 4 sub-dimensions and 36 items, was found to be valid and reliable for use with the Turkish population.

  7. Feasibility and reliability of the modified Berg Balance Scale in persons with severe intellectual and visual disabilities

    NARCIS (Netherlands)

    Waninge, A.; van Wijck, R.; Steenbergen, B.; van der Schans, C. P.

    Background The purpose of this study was to determine the feasibility and reliability of the modified Berg Balance Scale (mBBS) in persons with severe intellectual and visual disabilities (severe multiple disabilities, SMD) assigned Gross Motor Function Classification System (GMFCS) grades I and II.

  8. Reliability and validity of the Chinese mandarin version of PedsQL™ 3.0 transplant module.

    Science.gov (United States)

    Chang, Ying; Luo, Yanhui; Zhou, Yuchen; Wang, Ruixin; Song, Na; Zhu, Guanghua; Wang, Bin; Qin, Maoquan; Yang, Jun; Sun, Yuan; Li, Chunfu; Zhou, Xuan

    2016-10-05

    Long-term health-related quality of life (HRQoL) of pediatric patients after hematopoietic stem cell transplantation (HSCT) is increasingly studied worldwide. However, few studies have been performed in China, where no uniform scale is available; the PedsQL™ Cancer Module 3.0 Chinese Mandarin version has been used to evaluate HRQoL of patients after HSCT in China. This study aimed to assess the reliability and validity of the Chinese Mandarin version of PedsQL™ 3.0 Transplant Module. Patients between 2 and 18 years old, who underwent HSCT from January 2006 to June 2014, were recruited in Beijing Children's Hospital affiliated to Capital Medical University, the First Affiliated Hospital of Southern Medical University and Beijing Daopei Hospital. 207 parent reports and 182 child self-reports of the PedsQL™ 3.0 Transplant Module Chinese Mandarin version were assigned, of which 362 were returned. No missing item response was observed in the returned reports. Cronbach's alpha coefficient exceeded 0.7 in total scale and every dimension. The intraclass correlation coefficient exceeded 0.8 in all dimensions of child self-reports and parent reports. Spearman's rank correlation coefficients of items and their respective dimensions were 0.6-0.94 in parent reports, and 0.62-0.93 in child self-reports, while a weak association was found between the items and other dimensions. Exploratory factor analysis indicated a good extraction effect, and construct validity of the scale was >60 %. The Chinese Mandarin version of PedsQL™ 3.0 Transplant Module has good feasibility, reliability and validity. Its use may help improve the HRQoL of children after HSCT in China.

  9. A Computerized Approach to Trickle-Process, Random Assignment.

    Science.gov (United States)

    Braucht, G. Nicholas; Reichardt, Charles S.

    1993-01-01

    Procedures for implementing random assignment with trickle processing and ways they can be corrupted are described. A computerized method for implementing random assignment with trickle processing is presented as a desirable alternative in many situations and a way of protecting against threats to assignment validity. (SLD)

  10. Writing Assignments that Promote Active Learning

    Science.gov (United States)

    Narayanan, M.

    2014-12-01

    Encourage students to write a detailed, analytical report correlating classroom discussions to an important historical event or a current event. Motivate students interview an expert from industry on a topic that was discussed in class. Ask the students to submit a report with supporting sketches, drawings, circuit diagrams and graphs. Propose that the students generate a complete a set of reading responses pertaining to an assigned topic. Require each student to bring in one comment or one question about an assigned reading. The assignment should be a recent publication in an appropriate journal. Have the students conduct a web search on an assigned topic. Ask them to generate a set of ideas that can relate to classroom discussions. Provide the students with a study guide. The study guide should provide about 10 or 15 short topics. Quiz the students on one or two of the topics. Encourage the students to design or develop some creative real-world examples based on a chapter discussed or a topic of interest. Require that students originate, develop, support and defend a viewpoint using a specifically assigned material. Make the students practice using or utilizing a set of new technical terms they have encountered in an assigned chapter. Have students develop original examples explaining the different terms. Ask the students to select one important terminology from the previous classroom discussions. Encourage the students to explain why they selected that particular word. Ask them to talk about the importance of the terminology from the point of view of their educational objectives and future career. Angelo, T. A. (1991). Ten easy pieces: Assessing higher learning in four dimensions. In T. A. Angelo (Ed.), Classroom research: Early lessons from success (pp. 17-31). New Directions for Teaching and Learning, No. 46. San Francisco: Jossey-Bass.

  11. Test-Retest Reliability of fMRI During Nonverbal Semantic Decisions in Moderate-Severe Nonfluent Aphasia Patients

    Directory of Open Access Journals (Sweden)

    Jacquie Kurland

    2004-01-01

    Full Text Available Cortical reorganization in poststroke aphasia is not well understood. Few studies have investigated neural mechanisms underlying language recovery in severe aphasia patients, who are typically viewed as having a poor prognosis for language recovery. Although test-retest reliability is routinely demonstrated during collection of language data in single-subject aphasia research, this is rarely examined in fMRI studies investigating the underlying neural mechanisms in aphasia recovery.

  12. Diffusion tensor imaging fiber tracking with reliable tracking orientation and flexible step size☆

    Science.gov (United States)

    Yao, Xufeng; Wang, Manning; Chen, Xinrong; Nie, Shengdong; Li, Zhexu; Xu, Xiaoping; Zhang, Xuelong; Song, Zhijian

    2013-01-01

    We propose a method of reliable tracking orientation and flexible step size fiber tracking. A new directional strategy was defined to select one optimal tracking orientation from each directional set, which was based on the single-tensor model and the two-tensor model. The directional set of planar voxels contained three tracking directions: two from the two-tensor model and one from the single-tensor model. The directional set of linear voxels contained only one principal vector. In addition, a flexible step size, rather than fixable step sizes, was implemented to improve the accuracy of fiber tracking. We used two sets of human data to assess the performance of our method; one was from a healthy volunteer and the other from a patient with low-grade glioma. Results verified that our method was superior to the single-tensor Fiber Assignment by Continuous Tracking and the two-tensor eXtended Streamline Tractography for showing detailed images of fiber bundles. PMID:25206444

  13. Detecting Plagiarism in MS Access Assignments

    Science.gov (United States)

    Singh, Anil

    2013-01-01

    Assurance of individual effort from students in computer-based assignments is a challenge. Due to digitization, students can easily use a copy of their friend's work and submit it as their own. Plagiarism in assignments puts students who cheat at par with those who work honestly and this compromises the learning evaluation process. Using a…

  14. Reliability of ultrasonographic measurements in suspected patients of developmental dysplasia of the hip and correlation with the acetabular index

    Directory of Open Access Journals (Sweden)

    Cem Copuroglu

    2011-01-01

    Full Text Available Background: Ultrasonography is accepted as a useful imaging modality in the early detection of developmental dysplasia of the hip (DDH. Early detection and early treatment of DDH prevents hip dislocation and related physical, social, economic, and psychological problems. The purpose of this study was to evaluate the reliability of ultrasonographic and roentgenographic measurements measured by seven different observers. Materials and Methods: The alpha angles of 66 hips in 33 patients were measured using the Graf method by seven different observers. Acetabular index degrees on plane roentgenograms were measured in order to assess the correlation between the ultrasonographic alpha angle and the radiographic acetabular index, which both show the bony acetabular depth, retrospectively. Results: The interclass correlation coefficient, measuring the interobserver reliability, was high and statistically significant for the ultrasonographic measurements. There was a negative correlation between the alpha angle and the acetabular index. Conclusions: Ultrasonography, when applied properly, is a reliable technique between different observers, in the diagnosis and follow up of DDH. When assessed concomitantly with the roentgenographic measurements, the results are reliable and statistically meaningful.

  15. The Reliability and Validity of the Rosenberg Self-Esteem Scale with Japanese Patients After Stroke

    OpenAIRE

    篠原, 純子; 児玉, 和紀; 迫田, 勝則; 金久, 重子; 百本, 文子

    2002-01-01

    The reliability and validity of the Rosenberg Self-Esteem Scale with Japanese patients after stroke was examined. Subjects were outpatients between 6 months and 3 years post stroke of cerebral infarction. Two kinds of Self-Esteem were examined. One was that of the present time. The other was that of the past time (Respondents recalled their Self-Esteem before having a stroke). The respondents were 38 people who consisted of 26 males and 12 females. Twenty-eight of thirty-eight respondents ans...

  16. Validity, Reliability, and the Questionable Role of Psychometrics in Plastic Surgery

    Science.gov (United States)

    2014-01-01

    Summary: This report examines the meaning of validity and reliability and the role of psychometrics in plastic surgery. Study titles increasingly include the word “valid” to support the authors’ claims. Studies by other investigators may be labeled “not validated.” Validity simply refers to the ability of a device to measure what it intends to measure. Validity is not an intrinsic test property. It is a relative term most credibly assigned by the independent user. Similarly, the word “reliable” is subject to interpretation. In psychometrics, its meaning is synonymous with “reproducible.” The definitions of valid and reliable are analogous to accuracy and precision. Reliability (both the reliability of the data and the consistency of measurements) is a prerequisite for validity. Outcome measures in plastic surgery are intended to be surveys, not tests. The role of psychometric modeling in plastic surgery is unclear, and this discipline introduces difficult jargon that can discourage investigators. Standard statistical tests suffice. The unambiguous term “reproducible” is preferred when discussing data consistency. Study design and methodology are essential considerations when assessing a study’s validity. PMID:25289354

  17. Validity, Reliability, and the Questionable Role of Psychometrics in Plastic Surgery

    Directory of Open Access Journals (Sweden)

    Eric Swanson, MD

    2014-06-01

    Full Text Available Summary: This report examines the meaning of validity and reliability and the role of psychometrics in plastic surgery. Study titles increasingly include the word “valid” to support the authors’ claims. Studies by other investigators may be labeled “not validated.” Validity simply refers to the ability of a device to measure what it intends to measure. Validity is not an intrinsic test property. It is a relative term most credibly assigned by the independent user. Similarly, the word “reliable” is subject to interpretation. In psychometrics, its meaning is synonymous with “reproducible.” The definitions of valid and reliable are analogous to accuracy and precision. Reliability (both the reliability of the data and the consistency of measurements is a prerequisite for validity. Outcome measures in plastic surgery are intended to be surveys, not tests. The role of psychometric modeling in plastic surgery is unclear, and this discipline introduces difficult jargon that can discourage investigators. Standard statistical tests suffice. The unambiguous term “reproducible” is preferred when discussing data consistency. Study design and methodology are essential considerations when assessing a study’s validity.

  18. The Korean version of relative and absolute reliability of gait and balance assessment tools for patients with dementia in day care center and nursing home.

    Science.gov (United States)

    Lee, Han Suk; Park, Sun Wook; Chung, Hyung Kuk

    2017-11-01

    [Purpose] This study was aimed to determine the relative and absolute reliability of Korean version tools of the Berg Balance Scale (BBS), the Timed Up and Go (TUG), the Four-Meter Walking Test (4MWT) and the Groningen Meander Walking Test (GMWT) in patients with dementia. [Subjects and Methods] A total of 53 patients with dementia were tested on TUG, BBS, 4MWT and GMWT with a prospective cohort methodological design. Intra-class Correlation Coefficients (ICCs) to assess relative reliability and the standard error of measurement (SEM), minimal detectable change (MDC 95 ) and its percentage (MDC % ) to analyze the absolute reliability were calculated. [Results] Inter-rater reliability (ICC (2,3) ) of TUG, BBS and GMWT was 0.99 and that of 4MWT was 0.82. Inter-rater reliability was high for TUG, BBS and GMWT, with low SEM, MDC 95 , and MDC % . Inter-rater reliability was low for 4MWT, with high SEM, MDC 95 , and MDC % . Test-retest (ICC (2,3) ) of TUG, BBS and GMWT was 0.96-0.99 and Test-retest (ICC (2,3) ) of 4MWT was 0.85. The test-retest was high for TUG, BBS and GMWT, with low SEM, MDC 95 , and MDC % , but it was low for 4MWT, with high SEM, MDC 95 , and MDC % . [Conclusion] The relative reliability was high for all the assessment tools. The absolute reliability has a reasonable level of stability except the 4MWT.

  19. Automated Pre-processing for NMR Assignments with Reduced Tedium

    Energy Technology Data Exchange (ETDEWEB)

    2004-05-11

    An important rate-limiting step in the reasonance asignment process is accurate identification of resonance peaks in MNR spectra. NMR spectra are noisy. Hence, automatic peak-picking programs must navigate between the Scylla of reliable but incomplete picking, and the Charybdis of noisy but complete picking. Each of these extremes complicates the assignment process: incomplete peak-picking results in the loss of essential connectivities, while noisy picking conceals the true connectivities under a combinatiorial explosion of false positives. Intermediate processing can simplify the assignment process by preferentially removing false peaks from noisy peak lists. This is accomplished by requiring consensus between multiple NMR experiments, exploiting a priori information about NMR spectra, and drawing on empirical statistical distributions of chemical shift extracted from the BioMagResBank. Experienced NMR practitioners currently apply many of these techniques "by hand", which is tedious, and may appear arbitrary to the novice. To increase efficiency, we have created a systematic and automated approach to this process, known as APART. Automated pre-processing has three main advantages: reduced tedium, standardization, and pedagogy. In the hands of experienced spectroscopists, the main advantage is reduced tedium (a rapid increase in the ratio of true peaks to false peaks with minimal effort). When a project is passed from hand to hand, the main advantage is standardization. APART automatically documents the peak filtering process by archiving its original recommendations, the accompanying justifications, and whether a user accepted or overrode a given filtering recommendation. In the hands of a novice, this tool can reduce the stumbling block of learning to differentiate between real peaks and noise, by providing real-time examples of how such decisions are made.

  20. The implementation of the case assignment method of patient care at the Dr. A.J. Stals care and rehabilitation centre

    Directory of Open Access Journals (Sweden)

    N.L. Daniels

    1980-09-01

    Full Text Available The modern approach to the care of the mentally retarded in institutional settings is no longer to provide only custiodial care, but to train and rehabilitate each patient to be able to function at his maximal potential. This requires that each resident must have his abilities assessed and a programme implemented for his training, according to his particular needs and capabilities. Residents requiring similar training programmes are therefore grouped together under the care of one nurse, the number of residents in each group depending upon their selfcare skills. The nurse is assigned the responsibility of carrying out the training programme under the supervision of the Ward Sister and with the guidance of the multidisciplinary team under the leadership of the psychiatrist.

  1. [Validity, reliability, and acceptability of the brief version of the self-management knowledge, attitude, and behavior assessment scale for diabetes patients].

    Science.gov (United States)

    Wu, Y Z; Wang, W J; Feng, N P; Chen, B; Li, G C; Liu, J W; Liu, H L; Yang, Y Y

    2016-07-06

    To evaluate the validity, reliability, and acceptability of the brief version of the self-management knowledge, attitude, and behavior (KAB) assessment scale for diabetes patients. Diabetes patients who were managed at the Xinkaipu Community Health Service Center of Tianxin in Changsha, Hunan Province were selected for survey by cluster sampling. A total of 350 diabetes patients were surveyed using the brief scale to collect data on knowledge, attitudes, and behaviors of self-management. Content validity was evaluated by Pearson correlation coefficient between the brief scale and subscales of knowledge, attitude, and behavior. Structure validity was evaluated by factor analysis, and discrimination validity was evaluated by an independent sample t-test between the high-score and low-score groups. Reliability was tested by internal consistency reliability and split-half reliability. The evaluation indexes of internal consistency reliability were Cronbach's α coefficients, θ coefficient, and Ω coefficient. Acceptability was evaluated by valid response rate and completion time of the brief scale. A total of 346(98.9%) valid questionnaires were returned, with average survey time of (11.43±3.4) minutes. Average score of the brief scale was 78.85 ± 11.22; scores of the knowledge, attitude, and behavior subscales were 16.45 ± 4.42, 21.33 ± 2.03, and 41.07 ± 8.34, respectively. Pearson correlation coefficients between the brief scale and the knowledge, attitude, and behavior subscales were 0.92, 0.42, and 0.60, respectively; P-values were all less than 0.01, indicating that the face validity and content validity of the brief scale were achieved to a good level. The common factor cumulative variance contribution rate of the brief scale and three subscales was from 53.66% to 61.75%, which achieved more than 50% of the approved standard. There were 11 common factors; 41 of the total 42 items had factor loadings above 0.40 in their relevant common factor, indicating

  2. Assessing communication quality of consultations in primary care: initial reliability of the Global Consultation Rating Scale, based on the Calgary-Cambridge Guide to the Medical Interview

    Science.gov (United States)

    Burt, Jenni; Abel, Gary; Elmore, Natasha; Campbell, John; Roland, Martin; Benson, John; Silverman, Jonathan

    2014-01-01

    Objectives To investigate initial reliability of the Global Consultation Rating Scale (GCRS: an instrument to assess the effectiveness of communication across an entire doctor–patient consultation, based on the Calgary-Cambridge guide to the medical interview), in simulated patient consultations. Design Multiple ratings of simulated general practitioner (GP)–patient consultations by trained GP evaluators. Setting UK primary care. Participants 21 GPs and six trained GP evaluators. Outcome measures GCRS score. Methods 6 GP raters used GCRS to rate randomly assigned video recordings of GP consultations with simulated patients. Each of the 42 consultations was rated separately by four raters. We considered whether a fixed difference between scores had the same meaning at all levels of performance. We then examined the reliability of GCRS using mixed linear regression models. We augmented our regression model to also examine whether there were systematic biases between the scores given by different raters and to look for possible order effects. Results Assessing the communication quality of individual consultations, GCRS achieved a reliability of 0.73 (95% CI 0.44 to 0.79) for two raters, 0.80 (0.54 to 0.85) for three and 0.85 (0.61 to 0.88) for four. We found an average difference of 1.65 (on a 0–10 scale) in the scores given by the least and most generous raters: adjusting for this evaluator bias increased reliability to 0.78 (0.53 to 0.83) for two raters; 0.85 (0.63 to 0.88) for three and 0.88 (0.69 to 0.91) for four. There were considerable order effects, with later consultations (after 15–20 ratings) receiving, on average, scores more than one point higher on a 0–10 scale. Conclusions GCRS shows good reliability with three raters assessing each consultation. We are currently developing the scale further by assessing a large sample of real-world consultations. PMID:24604483

  3. Structural and reliability analysis of a patient satisfaction with cancer-related care measure: a multisite patient navigation research program study.

    Science.gov (United States)

    Jean-Pierre, Pascal; Fiscella, Kevin; Freund, Karen M; Clark, Jack; Darnell, Julie; Holden, Alan; Post, Douglas; Patierno, Steven R; Winters, Paul C

    2011-02-15

    Patient satisfaction is an important outcome measure of quality of cancer care and 1 of the 4 core study outcomes of the National Cancer Institute (NCI)-sponsored Patient Navigation Research Program to reduce race/ethnicity-based disparities in cancer care. There is no existing patient satisfaction measure that spans the spectrum of cancer-related care. The objective of this study was to develop a Patient Satisfaction With Cancer Care measure that is relevant to patients receiving diagnostic/therapeutic cancer-related care. The authors developed a conceptual framework, an operational definition of Patient Satisfaction With Cancer Care, and an item pool based on literature review, expert feedback, group discussion, and consensus. The 35-item Patient Satisfaction With Cancer Care measure was administered to 891 participants from the multisite NCI-sponsored Patient Navigation Research Program. Principal components analysis (PCA) was conducted for latent structure analysis. Internal consistency was assessed using Cronbach coefficient alpha (α). Divergent analysis was performed using correlation analyses between the Patient Satisfaction With Cancer Care, the Communication and Attitudinal Self-Efficacy-Cancer, and demographic variables. The PCA revealed a 1-dimensional measure with items forming a coherent set explaining 62% of the variance in patient satisfaction. Reliability assessment revealed high internal consistency (α ranging from 0.95 to 0.96). The Patient Satisfaction With Cancer Care demonstrated good face validity, convergent validity, and divergent validity, as indicated by moderate correlations with subscales of the Communication and Attitudinal Self-Efficacy-Cancer (all P .05). The Patient Satisfaction With Cancer Care is a valid tool for assessing satisfaction with cancer-related care for this sample. Copyright © 2010 American Cancer Society.

  4. Reliability analysis with linguistic data: An evidential network approach

    International Nuclear Information System (INIS)

    Zhang, Xiaoge; Mahadevan, Sankaran; Deng, Xinyang

    2017-01-01

    In practical applications of reliability assessment of a system in-service, information about the condition of a system and its components is often available in text form, e.g., inspection reports. Estimation of the system reliability from such text-based records becomes a challenging problem. In this paper, we propose a four-step framework to deal with this problem. In the first step, we construct an evidential network with the consideration of available knowledge and data. Secondly, we train a Naive Bayes text classification algorithm based on the past records. By using the trained Naive Bayes algorithm to classify the new records, we build interval basic probability assignments (BPA) for each new record available in text form. Thirdly, we combine the interval BPAs of multiple new records using an evidence combination approach based on evidence theory. Finally, we propagate the interval BPA through the evidential network constructed earlier to obtain the system reliability. Two numerical examples are used to demonstrate the efficiency of the proposed method. We illustrate the effectiveness of the proposed method by comparing with Monte Carlo Simulation (MCS) results. - Highlights: • We model reliability analysis with linguistic data using evidential network. • Two examples are used to demonstrate the efficiency of the proposed method. • We compare the results with Monte Carlo Simulation (MCS).

  5. Reliability of Measuring Lumbar Lordosis, Flexion and Extension Using Dual Inclinometer in Healthy Subjects and Patients with Non-Specific Chronic Low Back Pain

    Directory of Open Access Journals (Sweden)

    Samira Garmabi

    2012-07-01

    Full Text Available Objective: Accurate assessment of lumbar range of motion is of great value for both evaluating lumbar functions and monitoring treatment progress. Recent research indicates that there is no general consensus on the most valid and reliable method of measuring spinal range of motion. The purpose of this study was to determine the intra-rater reliability of lumbar flexion and extension measurements (within-day and between-days using the dual inclinometer technique.   Materials & Methods: Lumbar flexion and extension of 22 women (14 healthy and 8 with low back pain, were measured by the same examiner on three occasions. The first two measurements were taken with half an hour apart on the first occasion to assess the within-day reliability and the third measurement was taken one week later to assess the between-days reliability.  Results: Within-day lumbar lordosis, flexion and extension measurements using dual inclinometer technique were shown to be very reliable with high Intraclass Correlation Coefficients (ICC values (ICC were 98%, 77% and 69% for lordosis, flexion and extension measurements, respectively in healthy subjects and 94%, 95% and 69% for lordosis, flexion and extension measurements, respectively in patients group. Between-Days measurements also demonstrated high reliability with the high values of ICC (ICC were 96%, 70% and 67% for lordosis, flexion and extension measurements, in healthy subjects and 91%, 71% and 66% for lordosis, flexion and extension measurements, respectively in patients group. Conclusion: The results indicated that, the dual inclinometer technique appears to be a highly reliable method for measuring lumbar lordosis, flexion and extension and can be used as a reliable tool in the assessment of lumbar range of motion and monitoring therapeutic interventions.

  6. Assessment of reliability, validity, responsiveness and minimally important change of the German Hip dysfunction and osteoarthritis outcome score (HOOS) in patients with osteoarthritis of the hip.

    Science.gov (United States)

    Arbab, Dariusch; van Ochten, Johannes H M; Schnurr, Christoph; Bouillon, Bertil; König, Dietmar

    2017-12-01

    Patient-reported outcome measures are a critical tool in evaluating the efficacy of orthopedic procedures. The intention of this study was to evaluate reliability, validity, responsiveness and minimally important change of the German version of the Hip dysfunction and osteoarthritis outcome score (HOOS). The German HOOS was investigated in 251 consecutive patients before and 6 months after total hip arthroplasty. All patients completed HOOS, Oxford-Hip Score, Short-Form (SF-36) and numeric scales for pain and disability. Test-retest reliability, internal consistency, floor and ceiling effects, construct validity and minimal important change were analyzed. The German HOOS demonstrated excellent test-retest reliability with intraclass correlation coefficient values > 0.7. Cronbach´s alpha values demonstrated strong internal consistency. As hypothesized, HOOS subscales strongly correlated with corresponding OHS and SF-36 domains. All subscales showed excellent (effect size/standardized response means > 0.8) responsiveness between preoperative assessment and postoperative follow-up. The HOOS and all subdomains showed higher changes than the minimal detectable change which indicates true changes. The German version of the HOOS demonstrated good psychometric properties. It proved to be valid, reliable and responsive to the changes instrument for use in patients with hip osteoarthritis undergoing total hip replacement.

  7. Combining M-FISH and Quantum Dot technology for fast chromosomal assignment of transgenic insertions

    Directory of Open Access Journals (Sweden)

    Yusuf Mohammed

    2011-12-01

    Full Text Available Abstract Background Physical mapping of transgenic insertions by Fluorescence in situ Hybridization (FISH is a reliable and cost-effective technique. Chromosomal assignment is commonly achieved either by concurrent G-banding or by a multi-color FISH approach consisting of iteratively co-hybridizing the transgenic sequence of interest with one or more chromosome-specific probes at a time, until the location of the transgenic insertion is identified. Results Here we report a technical development for fast chromosomal assignment of transgenic insertions at the single cell level in mouse and rat models. This comprises a simplified 'single denaturation mixed hybridization' procedure that combines multi-color karyotyping by Multiplex FISH (M-FISH, for simultaneous and unambiguous identification of all chromosomes at once, and the use of a Quantum Dot (QD conjugate for the transgene detection. Conclusions Although the exploitation of the unique optical properties of QD nanocrystals, such as photo-stability and brightness, to improve FISH performance generally has been previously investigated, to our knowledge this is the first report of a purpose-designed molecular cytogenetic protocol in which the combined use of QDs and standard organic fluorophores is specifically tailored to assist gene transfer technology.

  8. First Trimester Fetal Gender Assignment by Ultrasound

    Directory of Open Access Journals (Sweden)

    Sabahattin Altunyurt

    2010-03-01

    Full Text Available Objective: To investigate the efficiency of genital tubercule angle on detecting fetal gender in first trimester by ultrasonography. Material-Method: Fetal sex assignment by ultrasound was carried out in 172 pregnancies at 11-13+6 weeks between 2007 June and 2007 December. Gestational age was determined by the measurement of crown-rump length (CRL. The ultrasound predictions were compared with actual sex at birth. Mid-sagittal planes of a section of the fetal genital tubercle were performed to identify the gender. Results: 155 of 172 patients’ data were achieved. The overall success rate was 92.3 % in sonographic assignment of fetal sex. The correct assignment rate in female fetuses was significantly higher than males (95.9 % - 88.8 % [p=0,001]. The correct identification of fetal sex improved with advancing gestational age from 89.3 % between 11-11+6 weeks, 92.5 % between 12-12+6 weeks and 93.4 % between 13-13+6 weeks (p=0,96. Conclusion: The fetal sex assignment by ultrasonography between 11-13+6 weeks had high success rate. The sensitivity of fetal sex assignment was not affected with fetus position and gestational age.

  9. The Verbal Rating Scale Is Reliable for Assessment of Postoperative Pain in Hip Fracture Patients

    DEFF Research Database (Denmark)

    Bech, R. D.; Lauritsen, J.; Ovesen, O.

    2015-01-01

    Background. Hip fracture patients represent a challenge to pain rating due to the high prevalence of cognitive impairment. Methods. Patients prospectively rated pain on the VRS. Furthermore, patients described the changes in pain after raising their leg, with one of five descriptors. Agreement...... between paired measures on the VRS at rest and by passive straight leg raise with a one-minute interval between ratings at rest and three-minute interval for straight leg raise was expressed by kappa coefficients. Reliability of this assessment of pain using the VRS was compared to the validity...... weighted kappa coefficients ranged from 0.68 (95% CI = 0.59-0.77) at leg raise to 0.75 (95% CI = 0.65-0.85) at rest. Unweighted kappa coefficients of agreement in recalled pain compared to agreement of paired VRS scores ranged from 0.57 (95% CI = 0.49-0.65) to 0.36 (95% CI = 0.31-0.41). Interpretation...

  10. Historical WBAN ID Assignments

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — 4"x6" index cards represent the first written assignments of Weather Bureau Army Navy (WBAN) station identifier numbers by the National Climatic Data Center....

  11. Metallic artifact mitigation and organ-constrained tissue assignment for Monte Carlo calculations of permanent implant lung brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Sutherland, J. G. H.; Miksys, N.; Thomson, R. M., E-mail: rthomson@physics.carleton.ca [Carleton Laboratory for Radiotherapy Physics, Department of Physics, Carleton University, Ottawa, Ontario K1S 5B6 (Canada); Furutani, K. M. [Department of Radiation Oncology, Mayo Clinic College of Medicine, Rochester, Minnesota 55905 (United States)

    2014-01-15

    Purpose: To investigate methods of generating accurate patient-specific computational phantoms for the Monte Carlo calculation of lung brachytherapy patient dose distributions. Methods: Four metallic artifact mitigation methods are applied to six lung brachytherapy patient computed tomography (CT) images: simple threshold replacement (STR) identifies high CT values in the vicinity of the seeds and replaces them with estimated true values; fan beam virtual sinogram replaces artifact-affected values in a virtual sinogram and performs a filtered back-projection to generate a corrected image; 3D median filter replaces voxel values that differ from the median value in a region of interest surrounding the voxel and then applies a second filter to reduce noise; and a combination of fan beam virtual sinogram and STR. Computational phantoms are generated from artifact-corrected and uncorrected images using several tissue assignment schemes: both lung-contour constrained and unconstrained global schemes are considered. Voxel mass densities are assigned based on voxel CT number or using the nominal tissue mass densities. Dose distributions are calculated using the EGSnrc user-code BrachyDose for{sup 125}I, {sup 103}Pd, and {sup 131}Cs seeds and are compared directly as well as through dose volume histograms and dose metrics for target volumes surrounding surgical sutures. Results: Metallic artifact mitigation techniques vary in ability to reduce artifacts while preserving tissue detail. Notably, images corrected with the fan beam virtual sinogram have reduced artifacts but residual artifacts near sources remain requiring additional use of STR; the 3D median filter removes artifacts but simultaneously removes detail in lung and bone. Doses vary considerably between computational phantoms with the largest differences arising from artifact-affected voxels assigned to bone in the vicinity of the seeds. Consequently, when metallic artifact reduction and constrained tissue

  12. Pairing students in clinical assignments to develop collaboration and communication skills.

    Science.gov (United States)

    Bartges, Mali

    2012-01-01

    Skillful collaboration and communication among healthcare team members are associated with favorable patient outcomes. Student nurses need opportunities for supervised development of these crucial and intertwined skills. The author describes the implementation of a practice-change project for simultaneously developing collaboration and communication skills by pairing prelicensure student nurses in clinical assignments. This easily adapted strategy increases options for faculty looking to stimulate student acquisition of these professional skills.

  13. Are patients reliable when self-reporting medication use? Validation of structured drug interviews and home visits by drug analysis and prescription data in acutely hospitalized patients

    DEFF Research Database (Denmark)

    Glintborg, Bente; Hillestrøm, Peter René; Olsen, Lenette Holm

    2007-01-01

    were compared to the patients' self-reported medication history. Information on prescribed drugs dispensed from any Danish pharmacy was collected from nationwide real-time pharmacy records. The authors performed home visits in a subgroup of 115 patients 4 weeks after their discharge. Stored drugs were......The medication history among hospitalized patients often relies on patients' self-reports due to insufficient communication between health care professionals. The aim of the present study was to estimate the reliability of patients' self-reported medication use. Five hundred patients admitted...... to an acute medical department at a Danish university hospital were interviewed on the day of admission about their recent medication use. Blood samples drawn immediately after admission were screened for contents of 5 drugs (digoxin, bendroflumethiazide, amlodipine, simvastatin, glimepiride), and the results...

  14. SCRAED - Simple and Complex Random Assignment in Experimental Designs

    OpenAIRE

    Alferes, Valentim R.

    2009-01-01

    SCRAED is a package of 37 self-contained SPSS syntax files that performs simple and complex random assignment in experimental designs. For between-subjects designs, SCRAED includes simple random assignment (no restrictions, forced equal sizes, forced unequal sizes, and unequal probabilities), block random assignment (simple and generalized blocks), and stratified random assignment (no restrictions, forced equal sizes, forced unequal sizes, and unequal probabilities). For within-subject...

  15. Validity and reliability testing of two instruments to measure breast cancer patients' concerns and information needs relating to radiation therapy

    Directory of Open Access Journals (Sweden)

    Kristjanson Linda J

    2007-11-01

    Full Text Available Abstract Background It is difficult to determine the most effective approach to patient education or tailor education interventions for patients in radiotherapy without tools that assess patients' specific radiation therapy information needs and concerns. Therefore, the aim of this study was to develop psychometrically sound tools to adequately determine the concerns and information needs of cancer patients during radiation therapy. Patients and Methods Two tools were developed to (1 determine patients concerns about radiation therapy (RT Concerns Scale and (2 ascertain patient's information needs at different time point during their radiation therapy (RT Information Needs Scale. Tools were based on previous research by the authors, published literature on breast cancer and radiation therapy and information behaviour research. Thirty-one breast cancer patients completed the questionnaire on one occasion and thirty participants completed the questionnaire on a second occasion to facilitate test-retest reliability. One participant's responses were removed from the analysis. Results were analysed for content validity, internal consistency and stability over time. Results Both tools demonstrated high internal consistency and adequate stability over time. The nine items in the RT Concerns Scale were retained because they met all pre-set psychometric criteria. Two items were deleted from the RT Information Needs Scale because they did not meet content validity criteria and did not achieve pre-specified criteria for internal consistency. This tool now contains 22 items. Conclusion This paper provides preliminary data suggesting that the two tools presented are reliable and valid and would be suitable for use in trials or in the clinical setting.

  16. The reliability of assigning individuals to cognitive states using the Mini Mental-State Examination: a population-based prospective cohort study.

    Science.gov (United States)

    Marioni, Riccardo E; Chatfield, Mark; Brayne, Carol; Matthews, Fiona E

    2011-09-06

    Previous investigations of test re-test reliability of the Mini-Mental State Examination (MMSE) have used correlations and statistics such as Cronbach's α to assess consistency. In practice, the MMSE is usually used to group individuals into cognitive states. The reliability of this grouping (state based approach) has not been fully explored. MMSE data were collected on a subset of 2,275 older participants (≥ 65 years) from the population-based Medical Research Council Cognitive Function and Ageing Study. Two measurements taken approximately two months apart were used to investigate three state-based categorisations. Descriptive statistics were used to determine how many people remained in the same cognitive group or went up or down groups. Weighted logistic regression was used to identify predictive characteristics of those who moved group. The proportion of people who remained in the same MMSE group at screen and follow-up assessment ranged from 58% to 78%. The proportion of individuals who went up one or more groups was roughly equal to the proportion that went down one or more groups; most of the change occurred when measurements were close to the cut-points. There was no consistently significant predictor for changing cognitive group. A state-based approach to analysing the reliability of the MMSE provided similar results to correlation analyses. State-based models of cognitive change or individual trajectory models using raw scores need multiple waves to help overcome natural variation in MMSE scores and to help identify true cognitive change.

  17. Reliability engineering

    International Nuclear Information System (INIS)

    Lee, Chi Woo; Kim, Sun Jin; Lee, Seung Woo; Jeong, Sang Yeong

    1993-08-01

    This book start what is reliability? such as origin of reliability problems, definition of reliability and reliability and use of reliability. It also deals with probability and calculation of reliability, reliability function and failure rate, probability distribution of reliability, assumption of MTBF, process of probability distribution, down time, maintainability and availability, break down maintenance and preventive maintenance design of reliability, design of reliability for prediction and statistics, reliability test, reliability data and design and management of reliability.

  18. Intensity assignments from historical earthquake data: issues of certainty and quality

    Directory of Open Access Journals (Sweden)

    R. M. W. Musson

    1998-06-01

    Full Text Available The use of macroseismic data in assessing parameters for historical earthquakes for use in seismic hazard assessment has thrown more attention on the way in which these data are treated. The processes involved in selecting which macroseismic data from a historical earthquake survive to the present day can be modelled as a series of filters, most of which are outside the control of the seismologist/historian, and which cause distortion in the resulting picture of the earthquake. The ways in which the data become distorted should be taken into account when interpreting the data as intensity values. One can usefully discriminate between the certainty of an intensity assignment (how well the data fits the scale and the quality of an intensity assignment (how well one can trust that the value is a true reflection of what really happened. The expression of uncertainty is usually in the form of ranged intensity values; the expression of quality requires an extra symbol or rating of some sort. A system is presented for three types of quality problems: reliability of intensity assessment, locational certainty or uncertainty, and veracity of the original data. Each of these is treated as a binary variable, giving a final quality code ranging from 0 (best to 7 (worst. This single integer quality code preserves three types of information which can then be expanded as required by computer programs designed to handle macroseismic data.

  19. Changing tides: increasing evidence to embrace a patient classification system.

    Science.gov (United States)

    Malloch, Kathy

    2012-01-01

    The effective use of a patient classification system (PCS) in a way that provides value to all health care organizations has yet to be realized given the challenging developmental pathway of these systems. As the science and technology of workforce management emerges along with evidence to support the relationships between nurse work and patient care needs, it is no longer appropriate to rely on systems that provide aggregated and minimal data to address the need for safer patient care and retention of nurses. Specificity about patient care needs in a valid and reliable PCS is essential on our pathway to improved resource utilization, improved decision making, integration of nurse cognitive and knowledge work, and management of variances from planned resource use. Advancements with technology, the ability to create and monitor equitable nurse-patient assignments, conceptual clarity, evidence, regulatory requirements, and professional role development point to a new receptiveness for PCSs.

  20. Reliability and validity of the workplace social distance scale.

    Science.gov (United States)

    Yoshii, Hatsumi; Mandai, Nozomu; Saito, Hidemitsu; Akazawa, Kouhei

    2014-10-29

    Self-stigma, defined by a negative attitude toward oneself combined with the consciousness of being a target of prejudice, is a critical problem for psychiatric patients. Self-stigma studies among psychiatric patients have indicated that high stigma is predictive of detrimental effects such as the delay of treatment and decreases in social participation in patients, and levels of self-stigma should be statistically evaluated. In this study, we developed the Workplace Social Distance Scale (WSDS), rephrasing the eight items of the Japanese version of the Social Distance Scale (SDSJ) to apply to the work setting in Japan. We examined the reliability and validity of the WSDS among 83 psychiatric patients. Factor analysis extracted three factors from the scale items: "work relations," "shallow relationships," and "employment." These factors are similar to the assessment factors of the SDSJ. Cronbach's alpha coefficient for the WSDS was 0.753. The split-half reliability for the WSDS was 0.801, indicating significant correlations. In addition, the WSDS was significantly correlated with the SDSJ. These findings suggest that the WSDS represents an approximation of self-stigma in the workplace among psychiatric patients. Our study assessed the reliability and validity of the WSDS for measuring self-stigma in Japan. Future studies should investigate the reliability and validity of the scale in other countries.

  1. GENERAL ISSUES CONCERNING THE ASSIGNMENT OF SOCIAL PARTS

    Directory of Open Access Journals (Sweden)

    Stela Mihăilescu

    2012-11-01

    Full Text Available By means of the present study, we try to offer a thorough image and an analysis concerning the assignment mode of social parts within a company having limited liability. The assignment of social parts is free and unrestricted except for the cases provided by article 202, paragraph 2 from Law no. 31/ 1990- the law of commercial companies with further modifications and completions and the ones provided in OUG no. 54/ 2010 concerning some measures for fighting fiscal evasion. By means of the assignment operation a transmission is made up by an assignment of social parts contract towards one or more already associated persons in the company or towards other individual or legal persons who are going to obtain the associate quality. The principle governing any assignment is the one of goods circulation freedom, a freedom restricted only by the public order and imperative judicial norms.

  2. Achieving High Reliability with People, Processes, and Technology.

    Science.gov (United States)

    Saunders, Candice L; Brennan, John A

    2017-01-01

    High reliability as a corporate value in healthcare can be achieved by meeting the "Quadruple Aim" of improving population health, reducing per capita costs, enhancing the patient experience, and improving provider wellness. This drive starts with the board of trustees, CEO, and other senior leaders who ingrain high reliability throughout the organization. At WellStar Health System, the board developed an ambitious goal to become a top-decile health system in safety and quality metrics. To achieve this goal, WellStar has embarked on a journey toward high reliability and has committed to Lean management practices consistent with the Institute for Healthcare Improvement's definition of a high-reliability organization (HRO): one that is committed to the prevention of failure, early identification and mitigation of failure, and redesign of processes based on identifiable failures. In the end, a successful HRO can provide safe, effective, patient- and family-centered, timely, efficient, and equitable care through a convergence of people, processes, and technology.

  3. Painful Memories: Reliability of Pain Intensity Recall at 3 Months in Senior Patients

    Directory of Open Access Journals (Sweden)

    Raoul Daoust

    2017-01-01

    Full Text Available Background. Validity of pain recall is questioned in research. Objective. To evaluate the reliability of pain intensity recall for seniors in an emergency department (ED. Methods. This study was part of a prospective multicenter project for seniors (≥65 years old treated in an ED for minor traumatic injury. Pain intensity (0–10 numerical rating scale was evaluated at the initial ED visit, at one week (baseline, and 3 months. At three months, patients were asked to recall the pain intensity they had at baseline. Results. 482 patients were interviewed (mean age 76.6 years, SD ± 7.3 and 72.8% were female. Intraclass correlation coefficient between pain at baseline and its recall was 0.24 (95% CI: 0.14–0.33. Senior patients tended to overestimate their pain intensity by a mean of 1.2 (95% CI: 0.9–1.5 units. A stepwise multiple regression analysis showed that the variance of baseline pain recall at 3 months was explained by pain at ED visit (11%, pain at 3 months (7%, and pain at baseline (2%. Conclusion. The accuracy of pain intensity recall after three months is poor in seniors and seems to be influenced by the pain experienced at the time of injury.

  4. A Student Assessment Tool for Standardized Patient Simulations (SAT-SPS): Psychometric analysis.

    Science.gov (United States)

    Castro-Yuste, Cristina; García-Cabanillas, María José; Rodríguez-Cornejo, María Jesús; Carnicer-Fuentes, Concepción; Paloma-Castro, Olga; Moreno-Corral, Luis Javier

    2018-05-01

    The evaluation of the level of clinical competence acquired by the student is a complex process that must meet various requirements to ensure its quality. The psychometric analysis of the data collected by the assessment tools used is a fundamental aspect to guarantee the student's competence level. To conduct a psychometric analysis of an instrument which assesses clinical competence in nursing students at simulation stations with standardized patients in OSCE-format tests. The construct of clinical competence was operationalized as a set of observable and measurable behaviors, measured by the newly-created Student Assessment Tool for Standardized Patient Simulations (SAT-SPS), which was comprised of 27 items. The categories assigned to the items were 'incorrect or not performed' (0), 'acceptable' (1), and 'correct' (2). 499 nursing students. Data were collected by two independent observers during the assessment of the students' performance at a four-station OSCE with standardized patients. Descriptive statistics were used to summarize the variables. The difficulty levels and floor and ceiling effects were determined for each item. Reliability was analyzed using internal consistency and inter-observer reliability. The validity analysis was performed considering face validity, content and construct validity (through exploratory factor analysis), and criterion validity. Internal reliability and inter-observer reliability were higher than 0.80. The construct validity analysis suggested a three-factor model accounting for 37.1% of the variance. These three factors were named 'Nursing process', 'Communication skills', and 'Safe practice'. A significant correlation was found between the scores obtained and the students' grades in general, as well as with the grades obtained in subjects with clinical content. The assessment tool has proven to be sufficiently reliable and valid for the assessment of the clinical competence of nursing students using standardized patients

  5. Stress Assignment in Reading Italian Polysyllabic Pseudowords

    Science.gov (United States)

    Sulpizio, Simone; Arduino, Lisa S.; Paizi, Despina; Burani, Cristina

    2013-01-01

    In 4 naming experiments we investigated how Italian readers assign stress to pseudowords. We assessed whether participants assign stress following distributional information such as stress neighborhood (the proportion and number of existent words sharing orthographic ending and stress pattern) and whether such distributional information affects…

  6. Assigning breed origin to alleles in crossbred animals.

    Science.gov (United States)

    Vandenplas, Jérémie; Calus, Mario P L; Sevillano, Claudia A; Windig, Jack J; Bastiaansen, John W M

    2016-08-22

    For some species, animal production systems are based on the use of crossbreeding to take advantage of the increased performance of crossbred compared to purebred animals. Effects of single nucleotide polymorphisms (SNPs) may differ between purebred and crossbred animals for several reasons: (1) differences in linkage disequilibrium between SNP alleles and a quantitative trait locus; (2) differences in genetic backgrounds (e.g., dominance and epistatic interactions); and (3) differences in environmental conditions, which result in genotype-by-environment interactions. Thus, SNP effects may be breed-specific, which has led to the development of genomic evaluations for crossbred performance that take such effects into account. However, to estimate breed-specific effects, it is necessary to know breed origin of alleles in crossbred animals. Therefore, our aim was to develop an approach for assigning breed origin to alleles of crossbred animals (termed BOA) without information on pedigree and to study its accuracy by considering various factors, including distance between breeds. The BOA approach consists of: (1) phasing genotypes of purebred and crossbred animals; (2) assigning breed origin to phased haplotypes; and (3) assigning breed origin to alleles of crossbred animals based on a library of assigned haplotypes, the breed composition of crossbred animals, and their SNP genotypes. The accuracy of allele assignments was determined for simulated datasets that include crosses between closely-related, distantly-related and unrelated breeds. Across these scenarios, the percentage of alleles of a crossbred animal that were correctly assigned to their breed origin was greater than 90 %, and increased with increasing distance between breeds, while the percentage of incorrectly assigned alleles was always less than 2 %. For the remaining alleles, i.e. 0 to 10 % of all alleles of a crossbred animal, breed origin could not be assigned. The BOA approach accurately assigns

  7. Validity and reliability of a Malay version of the brief illness perception questionnaire for patients with type 2 diabetes mellitus.

    Science.gov (United States)

    Chew, Boon-How; Vos, Rimke C; Heijmans, Monique; Shariff-Ghazali, Sazlina; Fernandez, Aaron; Rutten, Guy E H M

    2017-08-03

    Illness perceptions involve the personal beliefs that patients have about their illness and may influence health behaviours considerably. Since an instrument to measure these perceptions for Malay population in Malaysia is lacking, we translated and examined the psychometric properties of the Malay version of the Brief Illness Perception Questionnaire (MBIPQ) in adult patients with type 2 diabetes mellitus. The MBIPQ has nine items, all use a 0-10 response scale, except the ninth item about causal factors, which is an open-ended item. A standard procedure was used to translate and adapt the English BIPQ into Malay language. Construct validity was examined comparing item scores and scores on the Diabetes Management Self-Efficacy Scale, the Morisky Medication Adherence Scale, the World Health Organization Quality of Life-brief, the 9-item Patient Health Questionnaire, the 17-item Diabetes Distress Scale, HbA1c and the presence of complications. In addition, 2-week and 4-week test-retest reliability were studied. A total of 312 patients completed the MBIPQ. Out of this, 97 and 215 patients completed the 2- or 4-weeks test-retest reliability questionnaire, respectively. Moderate inter-items correlations were observed between illness perception dimensions (r = -0.31 to 0.53). MBIPQ items showed the expected correlations with self-efficacy (r = 0.35), medication adherence (r = 0.29), quality of life (r = -0.17 to 0.31) and depressive symptoms (r = -0.18 to 0.21). People with severe diabetes-related distress also were more concern (t-test = 4.01, p personal control (t-test = 2.07, p = 0.031). People with any diabetes-related complication perceived the consequences as more serious (t-test = 2.04, p = 0.044). The 2-week and 4-week test-retest reliabilities varied between ICC agreement 0.39 to 0.70 and 0.58 to 0.78, respectively. The psychometric properties of items in the MBIPQ are moderate. The MBIPQ showed good cross-cultural validity and moderate

  8. Reliability of the SF-36 in Japanese patients with systemic lupus erythematosus and its associations with disease activity and damage: a two-consecutive year prospective study.

    Science.gov (United States)

    Baba, S; Katsumata, Y; Okamoto, Y; Kawaguchi, Y; Hanaoka, M; Kawasumi, H; Yamanaka, H

    2018-03-01

    We aimed to validate the reliability of the Medical Outcomes Study Short Form-36 (SF-36) among Japanese patients with systemic lupus erythematosus (SLE). Japanese patients with SLE ( n = 233) completed the SF-36 and other related demographic questionnaires, and physicians simultaneously completed the SLE Disease Activity Index 2000 (SLEDAI-2K) and the Systemic Lupus International Collaborating Clinics Damage Index (SDI). Patients were prospectively followed for a repeat assessment the following year. The SF-36 subscales demonstrated acceptable internal consistency (Cronbach's α of 0.85-0.89), and an overall good test-retest reliability (intraclass correlation coefficient >0.70). The average baseline SF-36 subscale/summary scores except for "bodily pain" were significantly lower than those of the Japanese general population ( p 36 subscale/summary scores except for "vitality" and "mental component summary" at baseline, whereas the SLEDAI-2K did not. In the second year, "social functioning" and "mental component summary" of the SF-36 deteriorated among patients whose SDI or SLEDAI-2K score increased (effect sizes 36 demonstrated acceptable reliability among Japanese patients with SLE. Health-related quality of life measured by the SF-36 was reduced in Japanese patients with SLE and associated with disease damage, rather than disease activity.

  9. One-minute mental status examination for category fluency is more useful than mini-mental state examination to evaluate the reliability of insulin self-injection in elderly diabetic patients.

    Science.gov (United States)

    Yajima, Ken; Matsushita, Takaya; Sumitomo, Hidetaka; Sakurai, Hirofumi; Katayama, Takashi; Kanno, Kazuo; Sakai, Masashi; Shigeta, Masayuki; Shirabe, Shinichiro; Nakano, Tadasumi; Nishimura, Kazuhiro; Ueki, Akio; Kitaoka, Masafumi

    2014-05-04

    We investigated the factors associated with the reliability of insulin self-injection in elderly diabetic patients receiving insulin therapy. We enrolled diabetic patients aged ≥65 years and receiving insulin therapy, and assessed their cognitive function by the mini-mental state examination and 1-min mental status examination for category fluency. We also observed their technique of insulin self-injection, and evaluated whether or not patients were able to inject insulin by themselves according to nine defined details in terms of insulin self-injection. The predictive factors for the reliability of insulin self-injection were determined by univariate and multivariate logistic regression analysis. There were 278 participants (135 males, 143 females) enrolled in the present study. According to multivariate logistic regression analysis, only the 1-min mental status examination score was found to be a significant independent predictor of the reliability of insulin self-injection (odds ratio 0.75; 95% confidence interval 0.62-0.90; P = 0.002). The 1-min mental status examination for category fluency can be considered more useful than mini-mental state examination to evaluate the reliability of insulin self-injection in elderly diabetic patients receiving insulin therapy.

  10. Practice effects and test-re-test reliability of the Five Digit Test in patients with stroke over four serial assessments.

    Science.gov (United States)

    Chiu, En-Chi; Koh, Chia-Lin; Tsai, Chia-Yin; Lu, Wen-Shian; Sheu, Ching-Fan; Hsueh, I-Ping; Hsieh, Ching-Lin

    2014-01-01

    To investigate practice effect and test-re-test reliability of the Five Digit Test (FDT) over four serial assessments in patients with stroke. Single-group repeated measures design. Twenty-five patients with stroke were administered the FDT in four consecutive assessments every 2 weeks. The FDT contains four parts with five indices: 'basic measures of attention and processing speed', 'selective attention', 'alternating attention', 'ability of inhibition' and 'ability of switching'. The five indices of the FDT showed trivial-to-small practice effects (Cohen's d = 0.03-0.47) and moderate-to-excellent test-re-test reliability (intra-class correlation coefficient = 0.59-0.97). Practice effects of the five indices all appeared cumulative, but one index, 'basic measures of attention and processing speed', reached a plateau after the second assessment. The minimum and maximum values of the 90% confidence interval (CI) of reliable change index modified for practice (RCIp) for this index were [-17.6, 11.2]. One of five indices of the FDT reached a plateau, whose minimum and maximum values of the 90% CI RCIp are useful to determine whether the change in an individual's score is real. However, clinicians and researchers should be cautious when interpreting the test results of these four indices over repeated assessments.

  11. The reliability of fine-needle aspiration biopsy in terms of malignancy in patients with Hashimoto thyroiditis.

    Science.gov (United States)

    Kapan, Murat; Onder, Akin; Girgin, Sadullah; Ulger, Burak Veli; Firat, Ugur; Uslukaya, Omer; Oguz, Abdullah

    2015-02-01

    The aim of this study was to analyze the presence of malignancy in patients with Hashimoto's thyroiditis and to investigate the reliability of preoperative fine-needle aspiration biopsy (FNAB). The retrospective study included 44 patients who were operated on for nodular goiter between December 2010 and October 2011. The patients underwent thyroidectomy following a cytologic analysis plus FNAB. Hashimoto's thyroiditis was confirmed on histopathology in all patients. FNAB results were defined as benign in 14 (31.8%), suspicion for malignancy in 17 (38.6%), malignant in 9 (20.5%), and inadequate in 4 (9.1%). Following the thyroidectomy, presence of papillary thyroid carcinoma and follicular variant of papillary thyroid carcinoma were detected in 10 patients (22.7%) and 1 (2.3%) patient, respectively. The FNAB results were interpreted in terms of malignancy, which revealed the sensitivity as 80%; specificity, 40%; false positives, 69.2%; false negatives, 14.3%; positive predictive value, 31.8%; negative predictive value, 85.7%; and diagnostic accuracy, 50%. The coexistence of Hashimoto's thyroiditis with papillary thyroid carcinoma is quite common. The FNAB results for such cases are hard to evaluate, and they are likely to increase the number of false positives.

  12. TEST-RETEST RELIABILITY OF HAND GRIP STRENGTH MEASUREMENT USING A JAMAR HAND DYNAMOMETER IN PATIENTS WITH ACUTE AND CHRONIC CERVICAL RADICULOPATHY

    Directory of Open Access Journals (Sweden)

    Ejazi G

    2017-12-01

    Full Text Available Background: To evaluate the test-retest reliability of Jamar hand held dynamometer for measuring handgrip strength (HGS in patients with acute and chronic cervical radiculopathy and to find out the difference in measurement of the handgrip strength between acute and chronic cervical radiculopathy. Methods: A prospective, observational and non-experimental, the comparative study design was used. A sample of 72 subjects (37 women and 35 men suffering from cervical radiculopathy were divided into two groups i.e., Group A(acute and Group B(chronic, handgrip strength was measured using Jamar hand held dynamometer on two occasions by the same rater with an interval of 7-days. Data collection was based on standard guidelines of American Society of Hand Therapists. Three gripping trials (measured in Kg with patient’s arm in standardized arm position were recorded. The data was analyzed from the mean score obtained from the sample. Result: One-way Analysis of Variance(ANOVA was used to evaluate test-retest reliability and Tukey-Kramer Multiple Comparison Test used to find the difference between handgrip strength among acute and chronic Cervical radiculopathy cases. Greater P-value (>0.05 in both testing session, as well as 95% of the confidence interval, shows the reliability of the instrument and lesser p-value (0.05 in female subjects shows no significant difference in handgrip strength between the two groups. Conclusion: Excellent test-retest reliability for hand grip strength measurement was measured in patients with acute and chronic cervical radiculopathy shows that the equipment could be used as an assessment tool for this patient and significant difference exists among male handgrip strength between acute and chronic cervical radiculopathy cases whereas no difference exists among female handgrip strength between acute and chronic cervical radiculopathy cases.

  13. Integer Linear Programming for Constrained Multi-Aspect Committee Review Assignment

    Science.gov (United States)

    Karimzadehgan, Maryam; Zhai, ChengXiang

    2011-01-01

    Automatic review assignment can significantly improve the productivity of many people such as conference organizers, journal editors and grant administrators. A general setup of the review assignment problem involves assigning a set of reviewers on a committee to a set of documents to be reviewed under the constraint of review quota so that the reviewers assigned to a document can collectively cover multiple topic aspects of the document. No previous work has addressed such a setup of committee review assignments while also considering matching multiple aspects of topics and expertise. In this paper, we tackle the problem of committee review assignment with multi-aspect expertise matching by casting it as an integer linear programming problem. The proposed algorithm can naturally accommodate any probabilistic or deterministic method for modeling multiple aspects to automate committee review assignments. Evaluation using a multi-aspect review assignment test set constructed using ACM SIGIR publications shows that the proposed algorithm is effective and efficient for committee review assignments based on multi-aspect expertise matching. PMID:22711970

  14. The reliability and validity of a sexual functioning questionnaire.

    Science.gov (United States)

    Corty, E W; Althof, S E; Kurit, D M

    1996-01-01

    The present study assessed the reliability and validity of a measure of sexual functioning, the CMSH-SFQ, for male patients and their partners. The CMSH-SFQ measures erectile and orgasmic functioning, sexual drive, frequency of sexual behavior, and sexual satisfaction. Test-retest reliability was assessed with 19 males and 19 females for the baseline CMSH-SFQ. Criterion validity was measured by comparing the answers of 25 male patients to those of their partners at baseline and follow-up. The majority of items had acceptable levels of reliability and validity. The CMSH-SFQ provides a reliable and valid device that can be used to measure global sexual functioning in men and their partners and may be used to evaluate the efficacy of treatments for sexual dysfunctions. Limitations and suggestions for use of the CMSH-SFQ are addressed.

  15. Statistical Primer for Athletic Trainers: The Essentials of Understanding Measures of Reliability and Minimal Important Change.

    Science.gov (United States)

    Riemann, Bryan L; Lininger, Monica R

    2018-01-01

      To describe the concepts of measurement reliability and minimal important change.   All measurements have some magnitude of error. Because clinical practice involves measurement, clinicians need to understand measurement reliability. The reliability of an instrument is integral in determining if a change in patient status is meaningful.   Measurement reliability is the extent to which a test result is consistent and free of error. Three perspectives of reliability-relative reliability, systematic bias, and absolute reliability-are often reported. However, absolute reliability statistics, such as the minimal detectable difference, are most relevant to clinicians because they provide an expected error estimate. The minimal important difference is the smallest change in a treatment outcome that the patient would identify as important.   Clinicians should use absolute reliability characteristics, preferably the minimal detectable difference, to determine the extent of error around a patient's measurement. The minimal detectable difference, coupled with an appropriately estimated minimal important difference, can assist the practitioner in identifying clinically meaningful changes in patients.

  16. Assignment and Correspondence Tracking System - Tactical / Operational Reporting

    Data.gov (United States)

    Social Security Administration — Reporting data store for the Assignment and Correspondence Tracking System (ACT). ACT automates the assignment and tracking of correspondence processing within the...

  17. The reliability of assigning individuals to cognitive states using the Mini Mental-State Examination: a population-based prospective cohort study

    Directory of Open Access Journals (Sweden)

    Brayne Carol

    2011-09-01

    Full Text Available Abstract Background Previous investigations of test re-test reliability of the Mini-Mental State Examination (MMSE have used correlations and statistics such as Cronbach's α to assess consistency. In practice, the MMSE is usually used to group individuals into cognitive states. The reliability of this grouping (state based approach has not been fully explored. Methods MMSE data were collected on a subset of 2,275 older participants (≥ 65 years from the population-based Medical Research Council Cognitive Function and Ageing Study. Two measurements taken approximately two months apart were used to investigate three state-based categorisations. Descriptive statistics were used to determine how many people remained in the same cognitive group or went up or down groups. Weighted logistic regression was used to identify predictive characteristics of those who moved group. Results The proportion of people who remained in the same MMSE group at screen and follow-up assessment ranged from 58% to 78%. The proportion of individuals who went up one or more groups was roughly equal to the proportion that went down one or more groups; most of the change occurred when measurements were close to the cut-points. There was no consistently significant predictor for changing cognitive group. Conclusion A state-based approach to analysing the reliability of the MMSE provided similar results to correlation analyses. State-based models of cognitive change or individual trajectory models using raw scores need multiple waves to help overcome natural variation in MMSE scores and to help identify true cognitive change.

  18. Statistical aspects of optimal treatment assignment

    OpenAIRE

    van der Linden, Willem J.

    1980-01-01

    The issues of treatment assignment is ordinarily dealt with within the framework of testing aptitude treatment interaction (ATI) hypothesis. ATI research mostly uses linear regression techniques, and an ATI exists when the aptitude treatment (AT) regression lines cross each other within the relevant interval of the aptitude variable. Consistent with this approach is the use of the points of interaction of AT regression lines as treatment-assignment rule. The replacement of such rules by monot...

  19. One of My Favorite Assignments: Automated Teller Machine Simulation.

    Science.gov (United States)

    Oberman, Paul S.

    2001-01-01

    Describes an assignment for an introductory computer science class that requires the student to write a software program that simulates an automated teller machine. Highlights include an algorithm for the assignment; sample file contents; language features used; assignment variations; and discussion points. (LRW)

  20. 7 CFR 1900.5 - Assignment of cases.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 12 2010-01-01 2010-01-01 false Assignment of cases. 1900.5 Section 1900.5 Agriculture Regulations of the Department of Agriculture (Continued) RURAL HOUSING SERVICE, RURAL BUSINESS... REGULATIONS GENERAL Delegations of Authority § 1900.5 Assignment of cases. The State Director may, in writing...

  1. METHOD FOR SOLVING FUZZY ASSIGNMENT PROBLEM USING MAGNITUDE RANKING TECHNIQUE

    OpenAIRE

    D. Selvi; R. Queen Mary; G. Velammal

    2017-01-01

    Assignment problems have various applications in the real world because of their wide applicability in industry, commerce, management science, etc. Traditional classical assignment problems cannot be successfully used for real life problem, hence the use of fuzzy assignment problems is more appropriate. In this paper, the fuzzy assignment problem is formulated to crisp assignment problem using Magnitude Ranking technique and Hungarian method has been applied to find an optimal solution. The N...

  2. The paradox of verbal autopsy in cause of death assignment: symptom question unreliability but predictive accuracy.

    Science.gov (United States)

    Serina, Peter; Riley, Ian; Hernandez, Bernardo; Flaxman, Abraham D; Praveen, Devarsetty; Tallo, Veronica; Joshi, Rohina; Sanvictores, Diozele; Stewart, Andrea; Mooney, Meghan D; Murray, Christopher J L; Lopez, Alan D

    2016-01-01

    subsets of symptoms to enable the Tariff Method to assign a COD. Questions which contributed most to COD prediction were also the most reliable and consistent across repeat interviews; these have been included in the short form VA questionnaire. Accuracy and reliability of diagnosis for an individual death depend on the quality of interview. This has considerable implications for the progressive roll out of VAs into civil registration and vital statistics (CRVS) systems.

  3. Rating scales for dystonia in cerebral palsy: reliability and validity.

    Science.gov (United States)

    Monbaliu, E; Ortibus, E; Roelens, F; Desloovere, K; Deklerck, J; Prinzie, P; de Cock, P; Feys, H

    2010-06-01

    This study investigated the reliability and validity of the Barry-Albright Dystonia Scale (BADS), the Burke-Fahn-Marsden Movement Scale (BFMMS), and the Unified Dystonia Rating Scale (UDRS) in patients with bilateral dystonic cerebral palsy (CP). Three raters independently scored videotapes of 10 patients (five males, five females; mean age 13 y 3 mo, SD 5 y 2 mo, range 5-22 y). One patient each was classified at levels I-IV in the Gross Motor Function Classification System and six patients were classified at level V. Reliability was measured by (1) intraclass correlation coefficient (ICC) for interrater reliability, (2) standard error of measurement (SEM) and smallest detectable difference (SDD), and (3) Cronbach's alpha for internal consistency. Validity was assessed by Pearson's correlations among the three scales used and by content analysis. Moderate to good interrater reliability was found for total scores of the three scales (ICC: BADS=0.87; BFMMS=0.86; UDRS=0.79). However, many subitems showed low reliability, in particular for the UDRS. SEM and SDD were respectively 6.36% and 17.72% for the BADS, 9.88% and 27.39% for the BFMMS, and 8.89% and 24.63% for the UDRS. High internal consistency was found. Pearson's correlations were high. Content validity showed insufficient accordance with the new CP definition and classification. Our results support the internal consistency and concurrent validity of the scales; however, taking into consideration the limitations in reliability, including the large SDD values and the content validity, further research on methods of assessment of dystonia is warranted.

  4. Rapid Screening of Psychological Well-Being of Patients with Chronic Illness: Reliability and Validity Test on WHO-5 and PHQ-9 Scales

    Directory of Open Access Journals (Sweden)

    Shu-Fang Vivienne Wu

    2014-01-01

    Full Text Available This study intended to test the reliability and validity of two simple psychological screening scales, the World Health Organization Well-being Index (WHO-5 and the 9-item Patient Health Questionnaire (PHQ-9, in patients with chronic illness in Taiwan and to understand the psychological well-being of patients with chronic illness (e.g., metabolic syndrome in Taiwan and the incidences of psychological problems that follow. The research design of this study was a descriptive cross-sectional study. The sample comprised 310 patients with metabolic syndrome (MS, aged 20 years or more, from the outpatient clinic of a municipal hospital in Taiwan. This study used questionnaires to collect basic information, including physiological indices, WHO-5 and PHQ-9 that were used. “Hospital Anxiety and Depression scale (HADS,” and “World Health Organization Quality of Life—Short-form Version for Taiwan (WHOQOL”. Results are as follows: (1 compared to PHQ-9, the reliability and validity of WHO-5 are better for screening the psychological well-being of patients with chronic illness. (2 The features of WHO-5 are high sensitivity, briefness, and ease-of-use. The incidence of depression in patients with metabolic syndrome was approximately 1.0–6.5%, which is significantly lower than that of western countries.

  5. A reliability study of the new sensors for movement analysis (SHARIF-HMIS).

    Science.gov (United States)

    Abedi, Mohen; Manshadi, Farideh Dehghan; Zavieh, Minoo Khalkhali; Ashouri, Sajad; Azimi, Hadi; Parnanpour, Mohamad

    2016-04-01

    SHARIF-HMIS is a new inertial sensor designed for movement analysis. The aim of the present study was to assess the inter-tester and intra-tester reliability of some kinematic parameters in different lumbar motions making use of this sensor. 24 healthy persons and 28 patients with low back pain participated in the current reliability study. The test was performed in five different lumbar motions consisting of lumbar flexion in 0, 15, and 30° in the right and left directions. For measuring inter-tester reliability, all the tests were carried out twice on the same day separately by two physiotherapists. Intra-tester reliability was assessed by reproducing the tests after 3 days by the same physiotherapist. The present study revealed satisfactory inter- and intra-tester reliability indices in different positions. ICCs for intra-tester reliability ranged from 0.65 to 0.98 and 0.59 to 0.81 for healthy and patient participants, respectively. Also, ICCs for inter-tester reliability ranged from 0.65 to 0.92 for the healthy and 0.65 to 0.87 for patient participants. In general, it can be inferred from the results that measuring the kinematic parameters in lumbar movements using inertial sensors enjoys acceptable reliability. Copyright © 2015 Elsevier Ltd. All rights reserved.

  6. A probabilistic approach for validating protein NMR chemical shift assignments

    International Nuclear Information System (INIS)

    Wang Bowei; Wang, Yunjun; Wishart, David S.

    2010-01-01

    It has been estimated that more than 20% of the proteins in the BMRB are improperly referenced and that about 1% of all chemical shift assignments are mis-assigned. These statistics also reflect the likelihood that any newly assigned protein will have shift assignment or shift referencing errors. The relatively high frequency of these errors continues to be a concern for the biomolecular NMR community. While several programs do exist to detect and/or correct chemical shift mis-referencing or chemical shift mis-assignments, most can only do one, or the other. The one program (SHIFTCOR) that is capable of handling both chemical shift mis-referencing and mis-assignments, requires the 3D structure coordinates of the target protein. Given that chemical shift mis-assignments and chemical shift re-referencing issues should ideally be addressed prior to 3D structure determination, there is a clear need to develop a structure-independent approach. Here, we present a new structure-independent protocol, which is based on using residue-specific and secondary structure-specific chemical shift distributions calculated over small (3-6 residue) fragments to identify mis-assigned resonances. The method is also able to identify and re-reference mis-referenced chemical shift assignments. Comparisons against existing re-referencing or mis-assignment detection programs show that the method is as good or superior to existing approaches. The protocol described here has been implemented into a freely available Java program called 'Probabilistic Approach for protein Nmr Assignment Validation (PANAV)' and as a web server (http://redpoll.pharmacy.ualberta.ca/PANAVhttp://redpoll.pharmacy.ualberta.ca/PANAV) which can be used to validate and/or correct as well as re-reference assigned protein chemical shifts.

  7. Reliability assessment of passive containment isolation system using APSRA methodology

    International Nuclear Information System (INIS)

    Nayak, A.K.; Jain, Vikas; Gartia, M.R.; Srivastava, A.; Prasad, Hari; Anthony, A.; Gaikwad, A.J.; Bhatia, S.; Sinha, R.K.

    2008-01-01

    In this paper, a methodology known as APSRA (Assessment of Passive System ReliAbility) has been employed for evaluation of the reliability of passive systems. The methodology has been applied to the passive containment isolation system (PCIS) of the Indian advanced heavy water reactor (AHWR). In the APSRA methodology, the passive system reliability evaluation is based on the failure probability of the system to carryout the desired function. The methodology first determines the operational characteristics of the system and the failure conditions by assigning a predetermined failure criterion. The failure surface is predicted using a best estimate code considering deviations of the operating parameters from their nominal states, which affect the PCIS performance. APSRA proposes to compare the code predictions with the test data to generate the uncertainties on the failure parameter prediction, which is later considered in the code for accurate prediction of failure surface of the system. Once the failure surface of the system is predicted, the cause of failure is examined through root diagnosis, which occurs mainly due to failure of mechanical components. The failure probability of these components is evaluated through a classical PSA treatment using the generic data. The reliability of the PCIS is evaluated from the probability of availability of the components for the success of the passive containment isolation system

  8. Test-retest reliability of the Progressive Isoinertial Lifting Evaluation (PILE).

    Science.gov (United States)

    Lygren, Hildegunn; Dragesund, Tove; Joensen, Jón; Ask, Tove; Moe-Nilssen, Rolf

    2005-05-01

    A repeated measures single group design. To investigate test-retest reliability of Progressive Isoinertial Lifting Evaluation on patients with long lasting musculoskeletal problems related to the lumbar spine. Test-retest reliability has been satisfactory in healthy men. Test-retest reliability for clinical populations has not been reported. A total of 31 patients (17 women and 14 men) with long lasting low back pain participated in the study. The patients were tested twice at an interval of 2 days and at the same time of the day. The heaviest load that the patient could lift 4 times was used as outcome measure. The error of measurement indicates that the true result in 95% of cases will be within +/-4.5 kg from the measured value, while the difference between 2 measurements in 95% of cases will be less than 6.4 kg. Intra-class correlation (1,1) was 0.91. Relative test-retest reliability was high assessed by intra-class correlation, but absolute measurement variability reported as the smallest detectable difference has relevance for the interpretation of clinical test results and should also be considered.

  9. Testing the Effectiveness of Online Assignments in Theory of Finance

    Science.gov (United States)

    Batu, Michael; Bower, Nancy; Lun, Esmond; Sadanand, Asha

    2018-01-01

    The authors investigated the effectiveness of online versus paper assignments using final examination scores in three cohorts of theory of finance. In particular, two cohorts were exposed to online assignments while another cohort was exposed to traditional assignments. The central result is that exposure to online assignments robustly leads to…

  10. Reliability and Repeatability of Cone Density Measurements in Patients With Stargardt Disease and RPGR-Associated Retinopathy.

    Science.gov (United States)

    Tanna, Preena; Kasilian, Melissa; Strauss, Rupert; Tee, James; Kalitzeos, Angelos; Tarima, Sergey; Visotcky, Alexis; Dubra, Alfredo; Carroll, Joseph; Michaelides, Michel

    2017-07-01

    To assess reliability and repeatability of cone density measurements by using confocal and (nonconfocal) split-detector adaptive optics scanning light ophthalmoscopy (AOSLO) imaging. It will be determined whether cone density values are significantly different between modalities in Stargardt disease (STGD) and retinitis pigmentosa GTPase regulator (RPGR)-associated retinopathy. Twelve patients with STGD (aged 9-52 years) and eight with RPGR-associated retinopathy (aged 11-31 years) were imaged using both confocal and split-detector AOSLO simultaneously. Four graders manually identified cone locations in each image that were used to calculate local densities. Each imaging modality was evaluated independently. The data set consisted of 1584 assessments of 99 STGD images (each image in two modalities and four graders who graded each image twice) and 928 RPGR assessments of 58 images (each image in two modalities and four graders who graded each image twice). For STGD assessments the reliability for confocal and split-detector AOSLO was 67.9% and 95.9%, respectively, and the repeatability was 71.2% and 97.3%, respectively. The differences in the measured cone density values between modalities were statistically significant for one grader. For RPGR assessments the reliability for confocal and split-detector AOSLO was 22.1% and 88.5%, respectively, and repeatability was 63.2% and 94.5%, respectively. The differences in cone density between modalities were statistically significant for all graders. Split-detector AOSLO greatly improved the reliability and repeatability of cone density measurements in both disorders and will be valuable for natural history studies and clinical trials using AOSLO. However, it appears that these indices may be disease dependent, implying the need for similar investigations in other conditions.

  11. The impact of intrinsic motivation on session attendance and reliable cognitive improvement in cognitive remediation in schizophrenia.

    Science.gov (United States)

    Bryce, S D; Lee, S J; Ponsford, J L; Lawrence, R J; Tan, E J; Rossell, S L

    2018-06-20

    Cognitive remediation (CR) is considered a potentially effective method of improving cognitive function in people with schizophrenia. Few studies, however, have explored the role of intrinsic motivation on treatment utilization or training outcomes in CR in this population. This study explored the impact of task-specific intrinsic motivation on attendance and reliable cognitive improvement in a controlled trial comparing CR with a computer game (CG) playing control. Forty-nine participants with schizophrenia or schizoaffective disorder, allocated to 10 weeks of group-based CR (n = 25) or CG control (n = 24), provided complete outcome data at baseline. Forty-three participants completed their assigned intervention. Cognition, psychopathology and intrinsic motivation were measured at baseline and end-treatment. Regression analyses explored the relative contribution of baseline motivation and other clinical factors to session attendance as well as the association of baseline and change in intrinsic motivation with the odds of reliable cognitive improvement (calculated using reliable change indices). Baseline reports of perceived program value were the only significant multivariable predictor of session attendance when including global cognition and psychiatric symptomatology. The odds of reliable cognitive improvement significantly increased with greater improvements in program interest and value from baseline to end-treatment. Motivational changes over time were highly variable between participants. Task-specific intrinsic motivation in schizophrenia may represent an important patient-related factor that contributes to session attendance and cognitive improvements in CR. Regular evaluation and enhancement of intrinsic motivation in cognitively enhancing interventions may optimize treatment engagement and the likelihood of meaningful training outcomes. Copyright © 2018 Elsevier B.V. All rights reserved.

  12. Validity and Reliability Study of the Korean Tinetti Mobility Test for Parkinson's Disease.

    Science.gov (United States)

    Park, Jinse; Koh, Seong-Beom; Kim, Hee Jin; Oh, Eungseok; Kim, Joong-Seok; Yun, Ji Young; Kwon, Do-Young; Kim, Younsoo; Kim, Ji Seon; Kwon, Kyum-Yil; Park, Jeong-Ho; Youn, Jinyoung; Jang, Wooyoung

    2018-01-01

    Postural instability and gait disturbance are the cardinal symptoms associated with falling among patients with Parkinson's disease (PD). The Tinetti mobility test (TMT) is a well-established measurement tool used to predict falls among elderly people. However, the TMT has not been established or widely used among PD patients in Korea. The purpose of this study was to evaluate the reliability and validity of the Korean version of the TMT for PD patients. Twenty-four patients diagnosed with PD were enrolled in this study. For the interrater reliability test, thirteen clinicians scored the TMT after watching a video clip. We also used the test-retest method to determine intrarater reliability. For concurrent validation, the unified Parkinson's disease rating scale, Hoehn and Yahr staging, Berg Balance Scale, Timed-Up and Go test, 10-m walk test, and gait analysis by three-dimensional motion capture were also used. We analyzed receiver operating characteristic curve to predict falling. The interrater reliability and intrarater reliability of the Korean Tinetti balance scale were 0.97 and 0.98, respectively. The interrater reliability and intra-rater reliability of the Korean Tinetti gait scale were 0.94 and 0.96, respectively. The Korean TMT scores were significantly correlated with the other clinical scales and three-dimensional motion capture. The cutoff values for predicting falling were 14 points (balance subscale) and 10 points (gait subscale). We found that the Korean version of the TMT showed excellent validity and reliability for gait and balance and had high sensitivity and specificity for predicting falls among patients with PD.

  13. High-Reliability Health Care: Getting There from Here

    Science.gov (United States)

    Chassin, Mark R; Loeb, Jerod M

    2013-01-01

    Context Despite serious and widespread efforts to improve the quality of health care, many patients still suffer preventable harm every day. Hospitals find improvement difficult to sustain, and they suffer “project fatigue” because so many problems need attention. No hospitals or health systems have achieved consistent excellence throughout their institutions. High-reliability science is the study of organizations in industries like commercial aviation and nuclear power that operate under hazardous conditions while maintaining safety levels that are far better than those of health care. Adapting and applying the lessons of this science to health care offer the promise of enabling hospitals to reach levels of quality and safety that are comparable to those of the best high-reliability organizations. Methods We combined the Joint Commission's knowledge of health care organizations with knowledge from the published literature and from experts in high-reliability industries and leading safety scholars outside health care. We developed a conceptual and practical framework for assessing hospitals’ readiness for and progress toward high reliability. By iterative testing with hospital leaders, we refined the framework and, for each of its fourteen components, defined stages of maturity through which we believe hospitals must pass to reach high reliability. Findings We discovered that the ways that high-reliability organizations generate and maintain high levels of safety cannot be directly applied to today's hospitals. We defined a series of incremental changes that hospitals should undertake to progress toward high reliability. These changes involve the leadership's commitment to achieving zero patient harm, a fully functional culture of safety throughout the organization, and the widespread deployment of highly effective process improvement tools. Conclusions Hospitals can make substantial progress toward high reliability by undertaking several specific

  14. Safety, reliability, and validity of a physiologic definition of bronchopulmonary dysplasia.

    Science.gov (United States)

    Walsh, Michele C; Wilson-Costello, Deanna; Zadell, Arlene; Newman, Nancy; Fanaroff, Avroy

    2003-09-01

    Bronchopulmonary dysplasia (BPD) is the focus of many intervention trials, yet the outcome measure when based solely on oxygen administration may be confounded by differing criteria for oxygen administration between physicians. Thus, we wished to define BPD by a standardized oxygen saturation monitoring at 36 weeks corrected age, and compare this physiologic definition with the standard clinical definition of BPD based solely on oxygen administration. A total of 199 consecutive very low birthweight infants (VLBW, 501 to 1500 g birthweight) were assessed prospectively at 36+/-1 weeks corrected age. Neonates on positive pressure support or receiving >30% supplemental oxygen were assigned the outcome BPD. Those receiving or =88% for 60 minutes) or "BPD" (saturation reliability, test-retest reliability, and validity of the physiologic definition vs the clinical definition were assessed. A total of 199 VLBW were assessed, of whom 45 (36%) were diagnosed with BPD by the clinical definition of oxygen use at 36 weeks corrected age. The physiologic definition identified 15 infants treated with oxygen who successfully passed the saturation monitoring test in room air. The physiologic definition diagnosed BPD in 30 (24%) of the cohort. All infants were safely studied. The test was highly reliable (inter-rater reliability, kappa=1.0; test-retest reliability, kappa=0.83) and highly correlated with discharge home in oxygen, length of hospital stay, and hospital readmissions in the first year of life. The physiologic definition of BPD is safe, feasible, reliable, and valid and improves the precision of the diagnosis of BPD. This may be of benefit in future multicenter clinical trials.

  15. Test–retest reliability of Antonovsky’s 13-item sense of coherence scale in patients with handrelated disorders

    DEFF Research Database (Denmark)

    Hansen, Alice Ørts; Kristensen, Hanne Kaae; Cederlund, Ragnhild

    2016-01-01

    Purpose: To report on the distribution and test-retest reliability of Antonovsky’s 13-item Sense of Coherence (SOC-13) Scale in patients with hand-related disorders (HRD). Links between the SOC-13 score and factors such as age, number of days between date of injury and start of rehabilitation, ge...... to be a powerful tool to measure the ICF component personal factors, which could have an impact on patients’ rehabilitation outcomes....

  16. Patient Self-Report of Prior Laser Treatment Reliably Indicates Presence of Severe Diabetic Retinopathy

    Science.gov (United States)

    GRASSI, MICHAEL A.; MAZZULLA, D. ANTHONY; KNUDTSON, MICHAEL D.; HUANG, WENDY W.; LEE, KRISTINE E.; KLEIN, BARBARA E.; NICOLAE, DAN L.; KLEIN, RONALD

    2009-01-01

    PURPOSE To determine whether patient self-report of prior laser treatment can be used as a reliable tool for assessing the presence of severe diabetic retinopathy. DESIGN This was a retrospective study on two groups of diabetic subjects. METHODS One hundred patients with diabetes were recruited from the general eye and retina clinics at the University of Chicago Hospitals. The patients were asked, “Have you ever received laser treatment for your diabetic eye disease (DED)?” A chart review was then conducted noting if the patient had received either focal laser treatment for diabetic macular edema or panretinal photocoagulation for proliferative diabetic retinopathy. Data from the Wisconsin Epidemiological Study of Diabetic Retinopathy (WESDR) were also analyzed. Participant responses to the question “Have you had laser photocoagulation treatment for your eyes?” were analyzed with documentation of photocoagulation scars determined by grading seven-standard field color fundus photographs. RESULTS In the University of Chicago group, 96 of 100 (96%) of patients were accurate in reporting whether they had received previous laser treatment for DED (sensitivity 95.8%, specificity 96.1%, and positive predictive value 88.5%). In the WESDR analysis, 2,329 of 2,348 (99%) of participants were accurate in reporting whether they had prior laser treatment for DED (sensitivity 96.0%, specificity 99.5%, and positive predictive value 95.6%). CONCLUSIONS The high sensitivity and specificity of our results validate the use of patient self-report as a useful tool in assessing past laser treatment for severe diabetic retinopathy. Patient self-report may be a useful surrogate to clinical examination or medical record review to determine the presence of severe diabetic retinopathy. PMID:19054495

  17. 12 CFR 563e.28 - Assigned ratings.

    Science.gov (United States)

    2010-01-01

    ... 12 Banks and Banking 5 2010-01-01 2010-01-01 false Assigned ratings. 563e.28 Section 563e.28 Banks... for Assessing Performance § 563e.28 Assigned ratings. (a) Ratings in general. Subject to paragraphs (b... performance under the lending, investment and service tests, the community development test, the small savings...

  18. Privacy-Preserving Task Assignment in Spatial Crowdsourcing

    KAUST Repository

    Liu, An

    2017-09-20

    With the progress of mobile devices and wireless networks, spatial crowdsourcing (SC) is emerging as a promising approach for problem solving. In SC, spatial tasks are assigned to and performed by a set of human workers. To enable effective task assignment, however, both workers and task requesters are required to disclose their locations to untrusted SC systems. In this paper, we study the problem of assigning workers to tasks in a way that location privacy for both workers and task requesters is preserved. We first combine the Paillier cryptosystem with Yao’s garbled circuits to construct a secure protocol that assigns the nearest worker to a task. Considering that this protocol cannot scale to a large number of workers, we then make use of Geohash, a hierarchical spatial index to design a more efficient protocol that can securely find approximate nearest workers. We theoretically show that these two protocols are secure against semi-honest adversaries. Through extensive experiments on two real-world datasets, we demonstrate the efficiency and effectiveness of our protocols.

  19. Isometric abdominal wall muscle strength assessment in individuals with incisional hernia: a prospective reliability study

    DEFF Research Database (Denmark)

    Jensen, K. K.; Kjær, Michael; Jorgensen, L. N.

    2016-01-01

    Purpose To determine the reliability of measurements obtained by the Good Strength dynamometer, determining isometric abdominal wall and back muscle strength in patients with ventral incisional hernia (VIH) and healthy volunteers with an intact abdominal wall. Methods Ten patients with VIH and ten...... and extension showed excellent test–retest reliability for both patients with VIH (ICC 0.91 and 0.99) and healthy controls (ICC 0.97 and 0.96). Bland and Altman plots showed that no systematic bias was present for neither truncal flexion nor extension when assessing reliability. For patients with VIH...... and IPAQ was found. Conclusions The Good Strength dynamometer provided a reliable, low-cost measure of truncal flexion and extension in patients with VIH....

  20. Systems reliability/structural reliability

    International Nuclear Information System (INIS)

    Green, A.E.

    1980-01-01

    The question of reliability technology using quantified techniques is considered for systems and structures. Systems reliability analysis has progressed to a viable and proven methodology whereas this has yet to be fully achieved for large scale structures. Structural loading variants over the half-time of the plant are considered to be more difficult to analyse than for systems, even though a relatively crude model may be a necessary starting point. Various reliability characteristics and environmental conditions are considered which enter this problem. The rare event situation is briefly mentioned together with aspects of proof testing and normal and upset loading conditions. (orig.)

  1. The gothic arch: a reliable measurement for developmental dysplasia of the hip.

    Science.gov (United States)

    Herickhoff, Paul K; O'Brien, Megan K; Dolan, Lori A; Morcuende, Jose A; Peterson, Jonathan B; Weinstein, Stuart L

    2013-01-01

    The "Gothic Arch" is a radio-graphic finding on AP pelvis x-rays postulated to be predictive of hip osteoarthritis. The purpose of this study was to determine the reliability of measurement of the Gothic Arch in patients with no known hip pathology and patients with unilateral developmental dysplasia of the hip (DDH). After obtaining IRB approval, nine skeletally mature patients (18 hips) with no known hip pathology were selected to serve as the control group. The AP pelvis x-rays at skeletal maturity of eight patients (16 hips) with unilateral DDH treated with closed reduction and casting comprised the comparison group. A digitizing program was designed to measure the Gothic Arch based on landmarks identified by the user. Two pediatric orthopaedic surgeons and two orthopaedic residents completed the program on two separate occasions. Intra-and interobserver reliability were determined using intraclass cor-relation coefficients (ICC) for continuous variables. Both the unilateral DDH group and the control group demonstrated excellent inter- and intraobserver reliability (ICC >0.70) for base, height, area, and orientation of the Gothic Arch, but poor reliability (ICC Gothic Arch can be reliably measured on AP pelvis x-rays of patients with normal and dysplastic hips. III, Diagnostic study. See the Guidelines for Authors for a complete description of levels of evidence.

  2. How Reliable Are Administrative Data for Capturing Stroke Patients and Their Care

    Directory of Open Access Journals (Sweden)

    Joan Porter

    2016-10-01

    Full Text Available Background/Aims: The reliability of diagnostic coding of acute stroke and transient ischemic attack (TIA in administrative data is uncertain. The purpose of this study is to determine the agreement between administrative data sources and chart audit for the identification of stroke type, stroke risk factors, and the use of hospital-based diagnostic procedures in patients with stroke or TIA. Methods: Medical charts for a population-based sample of patients (n = 14,508 with ischemic stroke, intracerebral hemorrhage (ICH, or TIA discharged from inpatient and emergency departments (ED in Ontario, Canada, between April 1, 2012 and March 31, 2013, were audited by trained abstractors. Audited data were linked and compared with hospital administrative data and physician billing data. The positive predictive value (PPV of hospital administrative data and kappa agreement for the reporting of stroke type were calculated. Kappa agreement was also determined for stroke risk factors and for select stroke-related procedures. Results: The PPV for stroke type in inpatient administrative data ranged from 89.5% (95% CI 88.0-91.0 for TIA, 91.9% (95% CI 90.2-93.5 for ICH, and 97.3% (95% CI 96.9-97.7 for ischemic stroke. For ED administrative data, PPV varied from 78.8% (95% CI 76.3-81.2 for ischemic, 86.3% (95% CI 76.8-95.7 for ICH, and 95.3% (95% CI 94.6-96.0 for TIA. The chance-corrected agreement between the audited and administrative data was good for atrial fibrillation (k = 0.60 and very good for diabetes (k = 0.86. Hospital administrative data combined with physician billing data more than doubled the observed agreement for carotid imaging (k = 0.65 and echocardiography (k = 0.66 compared to hospital administrative data alone. Conclusions: Inpatient and ED administrative data were found to be reliable in the reporting of the International Classification of Diagnosis, 10th revision, Canada (ICD-10-CA-coded ischemic stroke, ICH and TIA, and for the recording of

  3. Reliability Engineering

    International Nuclear Information System (INIS)

    Lee, Sang Yong

    1992-07-01

    This book is about reliability engineering, which describes definition and importance of reliability, development of reliability engineering, failure rate and failure probability density function about types of it, CFR and index distribution, IFR and normal distribution and Weibull distribution, maintainability and movability, reliability test and reliability assumption in index distribution type, normal distribution type and Weibull distribution type, reliability sampling test, reliability of system, design of reliability and functionality failure analysis by FTA.

  4. Reliability of hospital cost profiles in inpatient surgery.

    Science.gov (United States)

    Grenda, Tyler R; Krell, Robert W; Dimick, Justin B

    2016-02-01

    With increased policy emphasis on shifting risk from payers to providers through mechanisms such as bundled payments and accountable care organizations, hospitals are increasingly in need of metrics to understand their costs relative to peers. However, it is unclear whether Medicare payments for surgery can reliably compare hospital costs. We used national Medicare data to assess patients undergoing colectomy, pancreatectomy, and open incisional hernia repair from 2009 to 2010 (n = 339,882 patients). We first calculated risk-adjusted hospital total episode payments for each procedure. We then used hierarchical modeling techniques to estimate the reliability of total episode payments for each procedure and explored the impact of hospital caseload on payment reliability. Finally, we quantified the number of hospitals meeting published reliability benchmarks. Mean risk-adjusted total episode payments ranged from $13,262 (standard deviation [SD] $14,523) for incisional hernia repair to $25,055 (SD $22,549) for pancreatectomy. The reliability of hospital episode payments varied widely across procedures and depended on sample size. For example, mean episode payment reliability for colectomy (mean caseload, 157) was 0.80 (SD 0.18), whereas for pancreatectomy (mean caseload, 13) the mean reliability was 0.45 (SD 0.27). Many hospitals met published reliability benchmarks for each procedure. For example, 90% of hospitals met reliability benchmarks for colectomy, 40% for pancreatectomy, and 66% for incisional hernia repair. Episode payments for inpatient surgery are a reliable measure of hospital costs for commonly performed procedures, but are less reliable for lower volume operations. These findings suggest that hospital cost profiles based on Medicare claims data may be used to benchmark efficiency, especially for more common procedures. Copyright © 2016 Elsevier Inc. All rights reserved.

  5. Interrater reliability and accuracy of clinicians and trained research assistants performing prospective data collection in emergency department patients with potential acute coronary syndrome.

    Science.gov (United States)

    Cruz, Carlos O; Meshberg, Emily B; Shofer, Frances S; McCusker, Christine M; Chang, Anna Marie; Hollander, Judd E

    2009-07-01

    Clinical research requires high-quality data collection. Data collected at the emergency department evaluation is generally considered more precise than data collected through chart abstraction but is cumbersome and time consuming. We test whether trained research assistants without a medical background can obtain clinical research data as accurately as physicians. We hypothesize that they would be at least as accurate because they would not be distracted by clinical requirements. We conducted a prospective comparative study of 33 trained research assistants and 39 physicians (35 residents) to assess interrater reliability with respect to guideline-recommended clinical research data. Immediately after the research assistant and clinician evaluation, the data were compared by a tiebreaker third person who forced the patient to choose one of the 2 answers as the correct one when responses were discordant. Crude percentage agreement and interrater reliability were assessed (kappa statistic). One hundred forty-three patients were recruited (mean age 50.7 years; 47% female patients). Overall, the median agreement was 81% (interquartile range [IQR] 73% to 92%) and interrater reliability was fair (kappa value 0.36 [IQR 0.26 to 0.52]) but varied across categories of data: cardiac risk factors (median 86% [IQR 81% to 93%]; median 0.69 [IQR 0.62 to 0.83]), other cardiac history (median 93% [IQR 79% to 95%]; median 0.56 [IQR 0.29 to 0.77]), pain location (median 92% [IR 86% to 94%]; median 0.37 [IQR 0.25 to 0.29]), radiation (median 86% [IQR 85% to 87%]; median 0.37 [IQR 0.26 to 0.42]), quality (median 85% [IQR 75% to 94%]; median 0.29 [IQR 0.23 to 0.40]), and associated symptoms (median 74% [IQR 65% to 78%]; median 0.28 [IQR 0.20 to 0.40]). When discordant information was obtained, the research assistant was more often correct (median 64% [IQR 53% to 72%]). The relatively fair interrater reliability observed in our study is consistent with previous studies evaluating

  6. Reliability of the xipho-pubic angle in patients with sagittal imbalance of the spine.

    Science.gov (United States)

    Langella, Francesco; Villafañe, Jorge H; Ismael, Maryem; Buric, Josip; Piazzola, Andrea; Lamartina, Claudio; Berjano, Pedro

    2018-04-01

    Proximal junctional kyphosis (PJK) is a frequent complication that compromises the outcomes of spinal surgery, especially for adult deformity. To the date no single risk factor or cause has been identified that explains its occurrence. The purpose of this study was to investigate the test-retest reliability of the radiologic measurements using xipho-pubic angle (XPA) for subjects undergoing surgery for sagittal misalignment of the spine. Retrospective observational cross-sectional study of prospectively collected data. Full-spine standing lateral radiographs of 50 patients who underwent surgery for fixed sagittal imbalance (preoperative and postoperative) were evaluated. Internal consistency, reproducibility, concurrent validity, and discriminative ability of the XPA. Two physicians measured XPA on the 100 randomly sorted and anonymized radiographs on two occasions, one week apart (test and retest conditions), were calculated for inter and intraobserver agreement. Test-retest reliability of XPA measurement was excellent for pre- (ICC=0.98; P=0.001) and post-surgical (ICC=0.86; P=0.001) radiographs of subjects with sagittal imbalance of the spine. XPA was able to discriminate between preoperative and postoperative radiographs F=17.924, Pimbalance for both raters. There were significant differences between pre- vs. postoperative XPA, pelvic tilt, lumbar lordosis and sagittal vertical axis values (all Pimbalance.

  7. Reliability-Aware Cooperative Node Sleeping and Clustering in Duty-Cycled Sensors Networks

    Directory of Open Access Journals (Sweden)

    Jeungeun Song

    2018-01-01

    Full Text Available Duty-cycled sensor networks provide a new perspective for improvement of energy efficiency and reliability assurance of multi-hop cooperative sensor networks. In this paper, we consider the energy-efficient cooperative node sleeping and clustering problems in cooperative sensor networks where clusters of relay nodes jointly transmit sensory data to the next hop. Our key idea for guaranteeing reliability is to exploit the on-demand number of cooperative nodes, facilitating the prediction of personalized end-to-end (ETE reliability. Namely, a novel reliability-aware cooperative routing (RCR scheme is proposed to select k-cooperative nodes at every hop (RCR-selection. After selecting k cooperative nodes at every hop, all of the non-cooperative nodes will go into sleep status. In order to solve the cooperative node clustering problem, we propose the RCR-based optimal relay assignment and cooperative data delivery (RCR-delivery scheme to provide a low-communication-overhead data transmission and an optimal duty cycle for a given number of cooperative nodes when the network is dynamic, which enables part of cooperative nodes to switch into idle status for further energy saving. Through the extensive OPNET-based simulations, we show that the proposed scheme significantly outperforms the existing geographic routing schemes and beaconless geographic routings in wireless sensor networks with a highly dynamic wireless channel and controls energy consumption, while ETE reliability is effectively guaranteed.

  8. Incorporating breeding abundance into spatial assignments on continuous surfaces.

    Science.gov (United States)

    Rushing, Clark S; Marra, Peter P; Studds, Colin E

    2017-06-01

    Determining the geographic connections between breeding and nonbreeding populations, termed migratory connectivity, is critical to advancing our understanding of the ecology and conservation of migratory species. Assignment models based on stable isotopes historically have been an important tool for studying migratory connectivity of small-bodied species, but the low resolution of these assignments has generated interest into combining isotopes with other sources in information. Abundance is one of the most appealing data sources to include in isotope-based assignments, but there are currently no statistical methods or guidelines for optimizing the contribution of stable isotopes and abundance for inferring migratory connectivity. Using known-origin stable-hydrogen isotope samples of six Neotropical migratory bird species, we rigorously assessed the performance of assignment models that differentially weight the contribution of the isotope and abundance data. For two species with adequate sample sizes, we used Pareto optimality to determine the set of models that simultaneously minimized both assignment error rate and assignment area. We then assessed the ability of the top models from these two species to improve assignments of the remaining four species compared to assignments based on isotopes alone. We show that the increased precision of models that include abundance is often offset by a large increase in assignment error. However, models that optimally weigh the abundance data relative to the isotope data can result in higher precision and, in some cases, lower error than models based on isotopes alone. The top models, however, depended on the distribution of relative breeding abundance, with patchier distributions requiring stronger downweighting of abundance, and we present general guidelines for future studies. These results confirm that breeding abundance can be an important source of information for studies investigating broad-scale movements of

  9. Probabilistic risk assessment for a loss of coolant accident in McMaster Nuclear Reactor and application of reliability physics model for modeling human reliability

    Science.gov (United States)

    Ha, Taesung

    A probabilistic risk assessment (PRA) was conducted for a loss of coolant accident, (LOCA) in the McMaster Nuclear Reactor (MNR). A level 1 PRA was completed including event sequence modeling, system modeling, and quantification. To support the quantification of the accident sequence identified, data analysis using the Bayesian method and human reliability analysis (HRA) using the accident sequence evaluation procedure (ASEP) approach were performed. Since human performance in research reactors is significantly different from that in power reactors, a time-oriented HRA model (reliability physics model) was applied for the human error probability (HEP) estimation of the core relocation. This model is based on two competing random variables: phenomenological time and performance time. The response surface and direct Monte Carlo simulation with Latin Hypercube sampling were applied for estimating the phenomenological time, whereas the performance time was obtained from interviews with operators. An appropriate probability distribution for the phenomenological time was assigned by statistical goodness-of-fit tests. The human error probability (HEP) for the core relocation was estimated from these two competing quantities: phenomenological time and operators' performance time. The sensitivity of each probability distribution in human reliability estimation was investigated. In order to quantify the uncertainty in the predicted HEPs, a Bayesian approach was selected due to its capability of incorporating uncertainties in model itself and the parameters in that model. The HEP from the current time-oriented model was compared with that from the ASEP approach. Both results were used to evaluate the sensitivity of alternative huinan reliability modeling for the manual core relocation in the LOCA risk model. This exercise demonstrated the applicability of a reliability physics model supplemented with a. Bayesian approach for modeling human reliability and its potential

  10. Validity and reliability of a Malay version of the brief illness perception questionnaire for patients with type 2 diabetes mellitus

    Directory of Open Access Journals (Sweden)

    Boon-How Chew

    2017-08-01

    Full Text Available Abstract Background Illness perceptions involve the personal beliefs that patients have about their illness and may influence health behaviours considerably. Since an instrument to measure these perceptions for Malay population in Malaysia is lacking, we translated and examined the psychometric properties of the Malay version of the Brief Illness Perception Questionnaire (MBIPQ in adult patients with type 2 diabetes mellitus. Methods The MBIPQ has nine items, all use a 0–10 response scale, except the ninth item about causal factors, which is an open-ended item. A standard procedure was used to translate and adapt the English BIPQ into Malay language. Construct validity was examined comparing item scores and scores on the Diabetes Management Self-Efficacy Scale, the Morisky Medication Adherence Scale, the World Health Organization Quality of Life-brief, the 9-item Patient Health Questionnaire, the 17-item Diabetes Distress Scale, HbA1c and the presence of complications. In addition, 2-week and 4-week test-retest reliability were studied. Results A total of 312 patients completed the MBIPQ. Out of this, 97 and 215 patients completed the 2- or 4-weeks test-retest reliability questionnaire, respectively. Moderate inter-items correlations were observed between illness perception dimensions (r = −0.31 to 0.53. MBIPQ items showed the expected correlations with self-efficacy (r = 0.35, medication adherence (r = 0.29, quality of life (r = −0.17 to 0.31 and depressive symptoms (r = −0.18 to 0.21. People with severe diabetes-related distress also were more concern (t-test = 4.01, p < 0.001 and experienced lower personal control (t-test = 2.07, p = 0.031. People with any diabetes-related complication perceived the consequences as more serious (t-test = 2.04, p = 0.044. The 2-week and 4-week test-retest reliabilities varied between ICCagreement 0.39 to 0.70 and 0.58 to 0.78, respectively. Conclusions The psychometric properties

  11. Assessing physiotherapists' communication skills for promoting patient autonomy for self-management: reliability and validity of the communication evaluation in rehabilitation tool.

    Science.gov (United States)

    Murray, Aileen; Hall, Amanda; Williams, Geoffrey C; McDonough, Suzanne M; Ntoumanis, Nikos; Taylor, Ian; Jackson, Ben; Copsey, Bethan; Hurley, Deirdre A; Matthews, James

    2018-02-27

    To assess the inter-rater reliability and concurrent validity of the Communication Evaluation in Rehabilitation Tool, which aims to externally assess physiotherapists competency in using Self-Determination Theory-based communication strategies in practice. Audio recordings of initial consultations between 24 physiotherapists and 24 patients with chronic low back pain in four hospitals in Ireland were obtained as part of a larger randomised controlled trial. Three raters, all of whom had Ph.Ds in psychology and expertise in motivation and physical activity, independently listened to the 24 audio recordings and completed the 18-item Communication Evaluation in Rehabilitation Tool. Inter-rater reliability between all three raters was assessed using intraclass correlation coefficients. Concurrent validity was assessed using Pearson's r correlations with a reference standard, the Health Care Climate Questionnaire. The total score for the Communication Evaluation in Rehabilitation Tool is an average of all 18 items. Total scores demonstrated good inter-rater reliability (Intraclass Correlation Coefficient (ICC) = 0.8) and concurrent validity with the Health Care Climate Questionnaire total score (range: r = 0.7-0.88). Item-level scores of the Communication Evaluation in Rehabilitation Tool identified five items that need improvement. Results provide preliminary evidence to support future use and testing of the Communication Evaluation in Rehabilitation Tool. Implications for Rehabilitation Promoting patient autonomy is a learned skill and while interventions exist to train clinicians in these skills there are no tools to assess how well clinicians use these skills when interacting with a patient. The lack of robust assessment has severe implications regarding both the fidelity of clinician training packages and resulting outcomes for promoting patient autonomy. This study has developed a novel measurement tool Communication Evaluation in Rehabilitation Tool and a

  12. Reliability of trans-abdominal ultrasonography in determining exact location of placenta in patients of placenta previa major

    International Nuclear Information System (INIS)

    Zafar, M.; Hayat, N; Gul, U.

    2017-01-01

    Objective: To determine the reliability of trans-abdominal ultrasonographical localization of placenta in cases of placenta previa major, by taking peroperative finding as gold standard. Study Design: Validation study. Place and Duration of Study: Maternity ward, Obstetrics and Gynecology department, Military Hospital Rawalpindi from 2007 to 2008. Patients and Methods: A total of 100 patients fulfilling the inclusion and exclusion criteria were recruited for the study. These patients were admitted to the maternity ward, where trans-abdominal ultrasound was performed, site of the placenta and its relation to the internal os was documented. These patients under went elective cesarean section, during which the site and relation of the placenta to the internal os was confirmed. Results: The mean age of patients was 34.23 +- 6.76 years. Transabdominal ultrasound had a sensitivity of 93.4 percent in localizing major placenta previa while the specificity was 83 percent. Positive predictive value was 94.7 percent, negative predictive value was 80 percent and accuracy 91 percent. Conclusion: Trans-abdominal ultrasound was found highly effective in diagnosing and localizing placenta previa. (author)

  13. Which is the most useful patient-reported outcome in femoroacetabular impingement? Test-retest reliability of six questionnaires.

    Science.gov (United States)

    Hinman, Rana S; Dobson, Fiona; Takla, Amir; O'Donnell, John; Bennell, Kim L

    2014-03-01

    The most reliable patient-reported outcomes (PROs) for people with femoroacetabular impingement (FAI) is unknown because there have been no direct comparisons of questionnaires. Thus, the aim was to evaluate the test-retest reliability of six existing PROs in a single cohort of young active people with hip/groin pain consistent with a clinical diagnosis of FAI. Young adults with clinical FAI completed six PRO questionnaires on two occasions, 1-2 weeks apart. The PROs were modified Harris Hip Score, Hip dysfunction and Osteoarthritis Score, Hip Outcome Score, Non-Arthritic Hip Score, International Hip Outcome Tool, Copenhagen Hip and Groin Outcome Score. 30 young adults (mean age 24 years, SD 4 years, range 18-30 years; 15 men) with stable symptoms participated. Intraclass correlation coefficient(3,1) values ranged from 0.73 to 0.93 (95% CI 0.38 to 0.98) indicating that most questionnaires reached minimal reliability benchmarks. Measurement error at the individual level was quite large for most questionnaires (minimal detectable change (MDC95) 12.4-35.6, 95% CI 8.7 to 54.0). In contrast, measurement error at the group level was quite small for most questionnaires (MDC95 2.2-7.3, 95% CI 1.6 to 11). The majority of the questionnaires were reliable and precise enough for use at the group level. Samples of only 23-30 individuals were required to achieve acceptable measurement variation at the group level. Further direct comparisons of these questionnaires are required to assess other measurement properties such as validity, responsiveness and meaningful change in young people with FAI.

  14. Reliability assessment and correlation analysis of evaluating orthodontic treatment outcome in Chinese patients.

    Science.gov (United States)

    Song, Guang-Ying; Zhao, Zhi-He; Ding, Yin; Bai, Yu-Xing; Wang, Lin; He, Hong; Shen, Gang; Li, Wei-Ran; Baumrind, Sheldon; Geng, Zhi; Xu, Tian-Min

    2014-03-01

    This study aimed to assess the reliability of experienced Chinese orthodontists in evaluating treatment outcome and to determine the correlations between three diagnostic information sources. Sixty-nine experienced Chinese orthodontic specialists each evaluated the outcome of orthodontic treatment of 108 Chinese patients. Three different information sources: study casts (SC), lateral cephalometric X-ray images (LX) and facial photographs (PH) were generated at the end of treatment for 108 patients selected randomly from six orthodontic treatment centers throughout China. Six different assessments of treatment outcome were made by each orthodontist using data from the three information sources separately and in combination. Each assessment included both ranking and grading for each patient. The rankings of each of the 69 judges for the 108 patients were correlated with the rankings of each of the other judges yielding 13 873 Spearman rs values, ranging from -0.08 to +0.85. Of these, 90% were greater than 0.4, showing moderate-to-high consistency among the 69 orthodontists. In the combined evaluations, study casts were the most significant predictive component (R(2)=0.86, P<0.000 1), while the inclusion of lateral cephalometric films and facial photographs also contributed to a more comprehensive assessment (R(2)=0.96, P<0.000 1). Grading scores for SC+LX and SC+PH were highly significantly correlated with those for SC+LX+PH (r(SC+LX)vs.(SC+LX+PH)=0.96, r(SC+PH)vs.(SC+LX+PH)=0.97), showing that either SC+LX or SC+PH is an excellent substitute for all three combined assessment.

  15. Reliability

    OpenAIRE

    Condon, David; Revelle, William

    2017-01-01

    Separating the signal in a test from the irrelevant noise is a challenge for all measurement. Low test reliability limits test validity, attenuates important relationships, and can lead to regression artifacts. Multiple approaches to the assessment and improvement of reliability are discussed. The advantages and disadvantages of several different approaches to reliability are considered. Practical advice on how to assess reliability using open source software is provided.

  16. [Reliability of Primary Care computerised medication records].

    Science.gov (United States)

    García-Molina Sáez, Celia; Urbieta Sanz, Elena; Madrigal de Torres, Manuel; Piñera Salmerón, Pascual; Pérez Cárceles, María D

    2016-03-01

    To quantify and to evaluate the reliability of Primary Care (PC) computerised medication records of as an information source of patient chronic medications, and to identify associated factors with the presence of discrepancies. A descriptive cross-sectional study. General Referral Hospital in Murcia. Patients admitted to the cardiology-chest diseases unit, during the months of February to April 2013, on home treatment, who agreed to participate in the study. Evaluation of the reliability of Primary Care computerised medication records by analysing the concordance, by identifying discrepancies, between the active medication in these records and that recorded in pharmacist interview with the patient/caregiver. Identification of associated factors with the presence of discrepancies was analysed using a multivariate logistic regression. The study included a total of 308 patients with a mean of 70.9 years (13.0 SD). The concordance of active ingredients was 83.7%, and this decreased to 34.7% when taking the dosage into account. Discrepancies were found in 97.1% of patients. The most frequent discrepancy was omission of frequency (35.6%), commission (drug added unjustifiably) (14.6%), and drug omission (12.7%). Age older than 65 years (1.98 [1.08 to 3.64]), multiple chronic diseases (1.89 [1.04 to 3.42]), and have a narcotic or psychotropic drug prescribed (2.22 [1.16 to 4.24]), were the factors associated with the presence of discrepancies. Primary Care computerised medication records, although of undoubted interest, are not be reliable enough to be used as the sole source of information on patient chronic medications when admitted to hospital. Copyright © 2015 Elsevier España, S.L.U. All rights reserved.

  17. Dual earners’ willingness to accept an international assignment.

    NARCIS (Netherlands)

    van der Velde, E.G.; Bossink, C.J.H.; Jansen, P.G.W.

    2005-01-01

    Multinational organisations experience difficulties in finding managers willing to accept international assignments. This study has therefore focused on factors that can predict males' and females' willingness to accept international assignments, or to follow their partners on international

  18. Task assignment and coaching

    NARCIS (Netherlands)

    Dominguez-Martinez, S.

    2009-01-01

    An important task of a manager is to motivate her subordinates. One way in which a manager can give incentives to junior employees is through the assignment of tasks. How a manager allocates tasks in an organization, provides information to the junior employees about his ability. Without coaching

  19. Validity and reliability testing of two instruments to measure breast cancer patients' concerns and information needs relating to radiation therapy

    International Nuclear Information System (INIS)

    Halkett, Georgia KB; Kristjanson, Linda J

    2007-01-01

    It is difficult to determine the most effective approach to patient education or tailor education interventions for patients in radiotherapy without tools that assess patients' specific radiation therapy information needs and concerns. Therefore, the aim of this study was to develop psychometrically sound tools to adequately determine the concerns and information needs of cancer patients during radiation therapy. Two tools were developed to (1) determine patients concerns about radiation therapy (RT Concerns Scale) and (2) ascertain patient's information needs at different time point during their radiation therapy (RT Information Needs Scale). Tools were based on previous research by the authors, published literature on breast cancer and radiation therapy and information behaviour research. Thirty-one breast cancer patients completed the questionnaire on one occasion and thirty participants completed the questionnaire on a second occasion to facilitate test-retest reliability. One participant's responses were removed from the analysis. Results were analysed for content validity, internal consistency and stability over time. Both tools demonstrated high internal consistency and adequate stability over time. The nine items in the RT Concerns Scale were retained because they met all pre-set psychometric criteria. Two items were deleted from the RT Information Needs Scale because they did not meet content validity criteria and did not achieve pre-specified criteria for internal consistency. This tool now contains 22 items. This paper provides preliminary data suggesting that the two tools presented are reliable and valid and would be suitable for use in trials or in the clinical setting

  20. Reliability and Repeatability of Cone Density Measurements in Patients With Stargardt Disease and RPGR-Associated Retinopathy

    Science.gov (United States)

    Tanna, Preena; Kasilian, Melissa; Strauss, Rupert; Tee, James; Kalitzeos, Angelos; Tarima, Sergey; Visotcky, Alexis; Dubra, Alfredo; Carroll, Joseph; Michaelides, Michel

    2017-01-01

    Purpose To assess reliability and repeatability of cone density measurements by using confocal and (nonconfocal) split-detector adaptive optics scanning light ophthalmoscopy (AOSLO) imaging. It will be determined whether cone density values are significantly different between modalities in Stargardt disease (STGD) and retinitis pigmentosa GTPase regulator (RPGR)–associated retinopathy. Methods Twelve patients with STGD (aged 9–52 years) and eight with RPGR-associated retinopathy (aged 11–31 years) were imaged using both confocal and split-detector AOSLO simultaneously. Four graders manually identified cone locations in each image that were used to calculate local densities. Each imaging modality was evaluated independently. The data set consisted of 1584 assessments of 99 STGD images (each image in two modalities and four graders who graded each image twice) and 928 RPGR assessments of 58 images (each image in two modalities and four graders who graded each image twice). Results For STGD assessments the reliability for confocal and split-detector AOSLO was 67.9% and 95.9%, respectively, and the repeatability was 71.2% and 97.3%, respectively. The differences in the measured cone density values between modalities were statistically significant for one grader. For RPGR assessments the reliability for confocal and split-detector AOSLO was 22.1% and 88.5%, respectively, and repeatability was 63.2% and 94.5%, respectively. The differences in cone density between modalities were statistically significant for all graders. Conclusions Split-detector AOSLO greatly improved the reliability and repeatability of cone density measurements in both disorders and will be valuable for natural history studies and clinical trials using AOSLO. However, it appears that these indices may be disease dependent, implying the need for similar investigations in other conditions. PMID:28738413

  1. Intertester reliability of the talk test in a cardiac rehabilitation population

    DEFF Research Database (Denmark)

    Petersen, Annemette Krintel; Maribo, Thomas; Hjortdal, Vibeke Elisabeth

    2013-01-01

    PURPOSE: The validity of the Talk Test (TT) is well documented, but the reliability of the test is not clear. The aim of this study was to assess the absolute and relative intertester reliability of the TT in cardiac patients. METHODS: Cardiac patients (n = 64) who had completed an exercise...... randomized to tests. Workload in watts at the first negative stage of the TT was registered as the test result. Patients and physiotherapists were blinded to test results of the first test. Absolute reliability of the TT was assessed with Bland-Altman plot, standard error of measurement, and minimal...... detectable change. Relative reliability was assessed using the intraclass correlation coefficient (ICC). RESULTS: Mean difference in peak workload between test and retest was 0.8 W (95% CI: -4.8 to 3.3). Limit of agreement was estimated to be +31/-32 W. Standard error of measurement was 11 W (95% CI: 10...

  2. Introducing the Body-QoL®: A New Patient-Reported Outcome Instrument for Measuring Body Satisfaction-Related Quality of Life in Aesthetic and Post-bariatric Body Contouring Patients.

    Science.gov (United States)

    Danilla, Stefan; Cuevas, Pedro; Aedo, Sócrates; Dominguez, Carlos; Jara, Rocío; Calderón, María E; Al-Himdani, Sarah; Rios, Marco A; Taladriz, Cristián; Rodriguez, Diego; Gonzalez, Rolando; Lazo, Ángel; Erazo, Cristián; Benitez, Susana; Andrades, Patricio; Sepúlveda, Sergio

    2016-02-01

    To develop a new patient-reported outcome instrument (PRO) to measure body-related satisfaction quality of life (QoL). Standard 3-phase PRO design was followed; in the first phase, a qualitative design was used in 45 patients to develop a conceptual framework and to create preliminary scale domains and items. In phase 2, large-scale population testing on 1340 subjects was performed to reduce items and domains. In phase 3, final testing of the developed instrument on 34 patients was performed. Statistics used include Factor, RASCH, and multivariate regression analysis. Psychometric properties measured were internal reliability, item-rest, item-test, and test-retest correlations. The PRO-developed instrument is composed of four domains (satisfaction with the abdomen, sex life, self-esteem and social life, and physical symptoms) and 20 items in total. The score can range from 20 (worst) to 100 (best). Responsiveness was 100 %, internal reliability 93.3 %, and test-retest concordance 97.7 %. Body image-related QoL was superior in men than women (p instrument (p measured reliably with the Body-QoL instrument. It can be used to quantify the improvement in cosmetic and post-bariatric patients including non- or minimally invasive procedures, suction assisted lipectomy, abdominoplasty, lipoabdominoplasty, and lower body lift and to give an evidence-based approach to standard practice. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266.

  3. Particle Swarm Optimization Algorithm for Optimizing Assignment of Blood in Blood Banking System

    Science.gov (United States)

    Olusanya, Micheal O.; Arasomwan, Martins A.; Adewumi, Aderemi O.

    2015-01-01

    This paper reports the performance of particle swarm optimization (PSO) for the assignment of blood to meet patients' blood transfusion requests for blood transfusion. While the drive for blood donation lingers, there is need for effective and efficient management of available blood in blood banking systems. Moreover, inherent danger of transfusing wrong blood types to patients, unnecessary importation of blood units from external sources, and wastage of blood products due to nonusage necessitate the development of mathematical models and techniques for effective handling of blood distribution among available blood types in order to minimize wastages and importation from external sources. This gives rise to the blood assignment problem (BAP) introduced recently in literature. We propose a queue and multiple knapsack models with PSO-based solution to address this challenge. Simulation is based on sets of randomly generated data that mimic real-world population distribution of blood types. Results obtained show the efficiency of the proposed algorithm for BAP with no blood units wasted and very low importation, where necessary, from outside the blood bank. The result therefore can serve as a benchmark and basis for decision support tools for real-life deployment. PMID:25815046

  4. Particle swarm optimization algorithm for optimizing assignment of blood in blood banking system.

    Science.gov (United States)

    Olusanya, Micheal O; Arasomwan, Martins A; Adewumi, Aderemi O

    2015-01-01

    This paper reports the performance of particle swarm optimization (PSO) for the assignment of blood to meet patients' blood transfusion requests for blood transfusion. While the drive for blood donation lingers, there is need for effective and efficient management of available blood in blood banking systems. Moreover, inherent danger of transfusing wrong blood types to patients, unnecessary importation of blood units from external sources, and wastage of blood products due to nonusage necessitate the development of mathematical models and techniques for effective handling of blood distribution among available blood types in order to minimize wastages and importation from external sources. This gives rise to the blood assignment problem (BAP) introduced recently in literature. We propose a queue and multiple knapsack models with PSO-based solution to address this challenge. Simulation is based on sets of randomly generated data that mimic real-world population distribution of blood types. Results obtained show the efficiency of the proposed algorithm for BAP with no blood units wasted and very low importation, where necessary, from outside the blood bank. The result therefore can serve as a benchmark and basis for decision support tools for real-life deployment.

  5. Device reliability challenges for modern semiconductor circuit design – a review

    Directory of Open Access Journals (Sweden)

    C. Schlünder

    2009-05-01

    Full Text Available Product development based on highly integrated semiconductor circuits faces various challenges. To ensure the function of circuits the electrical parameters of every device must be in a specific window. This window is restricted by competing mechanisms like process variations and device degradation (Fig. 1. Degradation mechanisms like Negative Bias Temperature Instability (NBTI or Hot Carrier Injection (HCI lead to parameter drifts during operation adding on top of the process variations.

    The safety margin between real lifetime of MOSFETs and product lifetime requirements decreases at advanced technologies. The assignment of tasks to ensure the product lifetime has to be changed for the future. Up to now technology development has the main responsibility to adjust the technology processes to achieve the required lifetime. In future, reliability can no longer be the task of technology development only. Device degradation becomes a collective challenge for semiconductor technologist, reliability experts and circuit designers. Reliability issues have to be considered in design as well to achieve reliable and competitive products. For this work, designers require support by smart software tools with built-in reliability know how. Design for reliability will be one of the key requirements for modern product designs.

    An overview will be given of the physical device damage mechanisms, the operation conditions within circuits leading to stress and the impact of the corresponding device parameter degradation on the function of the circuit. Based on this understanding various approaches for Design for Reliability (DfR will be described. The function of aging simulators will be explained and the flow of circuit-simulation will be described. Furthermore, the difference between full custom and semi custom design and therefore, the different required approaches will be discussed.

  6. Health-related quality of life: validity, reliability, and responsiveness of SF-36, 15D, EQ-5D RAQoL, and HAQ in patients with rheumatoid arthritis

    DEFF Research Database (Denmark)

    Linde, L.; Sørensen, J.; Østergaard, Morten

    2008-01-01

    OBJECTIVE: To compare validity, reliability, and responsiveness of generic and disease specific health-related quality of life (HRQOL) instruments in rheumatoid arthritis (RA). METHODS: Two samples of patients completed the Medical Outcomes Study Short Form-36 Health Survey (SF-36), EuroQol (EQ)-5D...... and VAS pain were responsive to both improvement and deterioration. CONCLUSION: All instruments were valid measures for HRQOL in RA. The RAQoL and HAQ displayed the best reliability, while the SF-36 bodily pain scale and VAS pain were the most responsive. The choice of instrument should depend......, 15D, Rheumatoid Arthritis Quality of Life Scale (RAQoL), Health Assessment Questionnaire (HAQ), and visual analog scales (VAS) for pain, fatigue, and global RA. Validity (convergent, discriminant, and known-groups) was evaluated in a cross-section of 200 patients. Reliability was evaluated...

  7. The validity and reliability of the Turkish version of Alzheimer's Disease Assessment Scale-Cognitive Subscale (ADAS-Cog) in patients with mild and moderate Alzheimer's disease and normal subjects.

    Science.gov (United States)

    Mavioglu, H; Gedizlioglu, M; Akyel, S; Aslaner, T; Eser, E

    2006-03-01

    The cognitive subscale of the Alzheimer's Disease Assesment Scale (ADAS-Cog) is the most widely used test in clinical trials dealing with Alzheimer's disease (AD). The aim of this study was to investigate the validity and reliability of the Turkish version of ADAS-Cog. Twenty-nine patients with AD, fulfilling NINCDS-ADRDA criteria of probable AD, who were in stage 3-5 according to the Global Deterioration Scale (GDS), and 27 non-demented control subjects with similar age, gender and educational status were recruited for the study. The Turkish version of ADAS-Cog, Standardized Mini Mental Status Examination (MMSE) and Short Orientation-Memory-Concentration Test (SOMCT) were applied to both of the groups. Inter-rater reliability, internal consistency, test-retest reliability; face validity, differential validity and convergent validity were statistically analyzed. Both MMSE and ADAS-Cog have significantly differentiated patients with AD and control subjects (p ADAS-Cog scores in AD group (r: -0.739). ADAS-Cog was also highly significantly correlated with GDS (r: 0.720) and SOMCT (r: 0.738). For the group with AD, control and whole cohort coefficients of internal consistency, Cronbach's alpha: 0.800, 0.515, 0.873 were found respectively. Inter-rater reliability for total ADAS-Cog score was found as ICC: 0.99 and 0.98 and test-retest reliability was found as ICC: 0.91 and 0.95 for demented and nondemented subjects, respectively. The Turkish version of ADAS-Cog has been found to be highly reliable and valid in differentiating patients with mild and moderate AD from nondemented subjects.

  8. Calibrated peer review assignments for the earth sciences

    Science.gov (United States)

    Rudd, J.A.; Wang, V.Z.; Cervato, C.; Ridky, R.W.

    2009-01-01

    Calibrated Peer Review ??? (CPR), a web-based instructional tool developed as part of the National Science Foundation reform initiatives in undergraduate science education, allows instructors to incorporate multiple writing assignments in large courses without overwhelming the instructor. This study reports successful implementation of CPR in a large, introductory geology course and student learning of geoscience content. For each CPR assignment in this study, students studied web-based and paper resources, wrote an essay, and reviewed seven essays (three from the instructor, three from peers, and their own) on the topic. Although many students expressed negative attitudes and concerns, particularly about the peer review process of this innovative instructional approach, they also recognized the learning potential of completing CPR assignments. Comparing instruction on earthquakes and plate boundaries using a CPR assignment vs. an instructional video lecture and homework essay with extensive instructor feedback, students mastered more content via CPR instruction.

  9. Subcarrier Group Assignment for MC-CDMA Wireless Networks

    Directory of Open Access Journals (Sweden)

    Le-Ngoc Tho

    2007-01-01

    Full Text Available Two interference-based subcarrier group assignment strategies in dynamic resource allocation are proposed for MC-CDMA wireless systems to achieve high throughput in a multicell environment. Least interfered group assignment (LIGA selects for each session the subcarrier group on which the user receives the minimum interference, while best channel ratio group assignment (BCRGA chooses the subcarrier group with the largest channel response-to-interference ratio. Both analytical framework and simulation model are developed for evaluation of throughput distribution of the proposed schemes. An iterative approach is devised to handle the complex interdependency between multicell interference profiles in the throughput analysis. Illustrative results show significant throughput improvement offered by the interference-based assignment schemes for MC-CDMA multicell wireless systems. In particular, under low loading conditions, LIGA renders the best performance. However, as the load increases BCRGA tends to offer superior performance.

  10. Subcarrier Group Assignment for MC-CDMA Wireless Networks

    Directory of Open Access Journals (Sweden)

    Tho Le-Ngoc

    2007-12-01

    Full Text Available Two interference-based subcarrier group assignment strategies in dynamic resource allocation are proposed for MC-CDMA wireless systems to achieve high throughput in a multicell environment. Least interfered group assignment (LIGA selects for each session the subcarrier group on which the user receives the minimum interference, while best channel ratio group assignment (BCRGA chooses the subcarrier group with the largest channel response-to-interference ratio. Both analytical framework and simulation model are developed for evaluation of throughput distribution of the proposed schemes. An iterative approach is devised to handle the complex interdependency between multicell interference profiles in the throughput analysis. Illustrative results show significant throughput improvement offered by the interference-based assignment schemes for MC-CDMA multicell wireless systems. In particular, under low loading conditions, LIGA renders the best performance. However, as the load increases BCRGA tends to offer superior performance.

  11. RNA-PAIRS: RNA probabilistic assignment of imino resonance shifts

    International Nuclear Information System (INIS)

    Bahrami, Arash; Clos, Lawrence J.; Markley, John L.; Butcher, Samuel E.; Eghbalnia, Hamid R.

    2012-01-01

    The significant biological role of RNA has further highlighted the need for improving the accuracy, efficiency and the reach of methods for investigating RNA structure and function. Nuclear magnetic resonance (NMR) spectroscopy is vital to furthering the goals of RNA structural biology because of its distinctive capabilities. However, the dispersion pattern in the NMR spectra of RNA makes automated resonance assignment, a key step in NMR investigation of biomolecules, remarkably challenging. Herein we present RNA Probabilistic Assignment of Imino Resonance Shifts (RNA-PAIRS), a method for the automated assignment of RNA imino resonances with synchronized verification and correction of predicted secondary structure. RNA-PAIRS represents an advance in modeling the assignment paradigm because it seeds the probabilistic network for assignment with experimental NMR data, and predicted RNA secondary structure, simultaneously and from the start. Subsequently, RNA-PAIRS sets in motion a dynamic network that reverberates between predictions and experimental evidence in order to reconcile and rectify resonance assignments and secondary structure information. The procedure is halted when assignments and base-parings are deemed to be most consistent with observed crosspeaks. The current implementation of RNA-PAIRS uses an initial peak list derived from proton-nitrogen heteronuclear multiple quantum correlation ( 1 H– 15 N 2D HMQC) and proton–proton nuclear Overhauser enhancement spectroscopy ( 1 H– 1 H 2D NOESY) experiments. We have evaluated the performance of RNA-PAIRS by using it to analyze NMR datasets from 26 previously studied RNAs, including a 111-nucleotide complex. For moderately sized RNA molecules, and over a range of comparatively complex structural motifs, the average assignment accuracy exceeds 90%, while the average base pair prediction accuracy exceeded 93%. RNA-PAIRS yielded accurate assignments and base pairings consistent with imino resonances for a

  12. RNA-PAIRS: RNA probabilistic assignment of imino resonance shifts

    Energy Technology Data Exchange (ETDEWEB)

    Bahrami, Arash; Clos, Lawrence J.; Markley, John L.; Butcher, Samuel E. [National Magnetic Resonance Facility at Madison (United States); Eghbalnia, Hamid R., E-mail: eghbalhd@uc.edu [University of Cincinnati, Department of Molecular and Cellular Physiology (United States)

    2012-04-15

    The significant biological role of RNA has further highlighted the need for improving the accuracy, efficiency and the reach of methods for investigating RNA structure and function. Nuclear magnetic resonance (NMR) spectroscopy is vital to furthering the goals of RNA structural biology because of its distinctive capabilities. However, the dispersion pattern in the NMR spectra of RNA makes automated resonance assignment, a key step in NMR investigation of biomolecules, remarkably challenging. Herein we present RNA Probabilistic Assignment of Imino Resonance Shifts (RNA-PAIRS), a method for the automated assignment of RNA imino resonances with synchronized verification and correction of predicted secondary structure. RNA-PAIRS represents an advance in modeling the assignment paradigm because it seeds the probabilistic network for assignment with experimental NMR data, and predicted RNA secondary structure, simultaneously and from the start. Subsequently, RNA-PAIRS sets in motion a dynamic network that reverberates between predictions and experimental evidence in order to reconcile and rectify resonance assignments and secondary structure information. The procedure is halted when assignments and base-parings are deemed to be most consistent with observed crosspeaks. The current implementation of RNA-PAIRS uses an initial peak list derived from proton-nitrogen heteronuclear multiple quantum correlation ({sup 1}H-{sup 15}N 2D HMQC) and proton-proton nuclear Overhauser enhancement spectroscopy ({sup 1}H-{sup 1}H 2D NOESY) experiments. We have evaluated the performance of RNA-PAIRS by using it to analyze NMR datasets from 26 previously studied RNAs, including a 111-nucleotide complex. For moderately sized RNA molecules, and over a range of comparatively complex structural motifs, the average assignment accuracy exceeds 90%, while the average base pair prediction accuracy exceeded 93%. RNA-PAIRS yielded accurate assignments and base pairings consistent with imino

  13. Reliability of inertial sensors in the assessment of patients with vestibular disorders: a feasibility study

    Directory of Open Access Journals (Sweden)

    Sathish K. Sankarpandi

    2017-02-01

    a commercially available wearable system a subset of reliable iTUG and iSway parameters were identified and their ability to classify fallers were estimated. These parameters have potential to augment assessments of vestibular patients to enable clinicians and therapists to provide objective, tailored, personalised interventions for their gait and postural control and also to objectively evaluate and monitor the efficiency of their interventions.

  14. Automated assignment and 3D structure calculations using combinations of 2D homonuclear and 3D heteronuclear NOESY spectra

    International Nuclear Information System (INIS)

    Oezguen, Numan; Adamian, Larisa; Xu Yuan; Rajarathnam, Krishna; Braun, Werner

    2002-01-01

    The NOAH/DIAMOD suite uses feedback filtering and self-correcting distance geometry to generate 3D structures from unassigned NOESY spectra. In this study we determined the minimum set of experiments needed to generate a high quality structure bundle. Different combinations of 3D 15 N-edited, 13 C-edited HSQC-NOESY and 2D homonuclear 1 H- 1 H NOESY spectra of the 77 amino acid protein, myeloid progenitor inhibitory factor-1 (MPIF-1) were used as input for NOAH/DIAMOD calculations. The quality of the assignments of NOESY cross peaks and the accuracy of the automatically generated 3D structures were compared to those obtained with a conventional manual procedure. Combining data from two types of experiments synergistically increased the number of peaks assigned unambiguously in both individual spectra. As a general trend for the accuracy of the structures we observed structural variations in the backbone fold of the final structures of about 2 A for single spectral data, of 1 A to 1.5 A for double spectral data, and of 0.6 A for triple spectral data sets. The quality of the assignments and 3D structures from the optimal data using all three spectra were similar to those obtained from traditional assignment methods with structural variations within the bundle of 0.6 A and 1.3 A for backbone and heavy atoms, respectively. Almost all constraints (97%) of the automatic NOESY cross peak assignments were cross compatible with the structures from the conventional manual assignment procedure, and an even larger proportion (99%) of the manually derived constraints were compatible with the automatically determined 3D structures. The two mean structures determined by both methods differed only by 1.3 A rmsd for the backbone atoms in the well-defined regions of the protein. Thus NOAD/DIAMOD analysis of spectra from labeled proteins provides a reliable method for high throughput analysis of genomic targets

  15. Advancing Usability Evaluation through Human Reliability Analysis

    International Nuclear Information System (INIS)

    Ronald L. Boring; David I. Gertman

    2005-01-01

    This paper introduces a novel augmentation to the current heuristic usability evaluation methodology. The SPAR-H human reliability analysis method was developed for categorizing human performance in nuclear power plants. Despite the specialized use of SPAR-H for safety critical scenarios, the method also holds promise for use in commercial off-the-shelf software usability evaluations. The SPAR-H method shares task analysis underpinnings with human-computer interaction, and it can be easily adapted to incorporate usability heuristics as performance shaping factors. By assigning probabilistic modifiers to heuristics, it is possible to arrive at the usability error probability (UEP). This UEP is not a literal probability of error but nonetheless provides a quantitative basis to heuristic evaluation. When combined with a consequence matrix for usability errors, this method affords ready prioritization of usability issues

  16. Interactive visual exploration and refinement of cluster assignments.

    Science.gov (United States)

    Kern, Michael; Lex, Alexander; Gehlenborg, Nils; Johnson, Chris R

    2017-09-12

    With ever-increasing amounts of data produced in biology research, scientists are in need of efficient data analysis methods. Cluster analysis, combined with visualization of the results, is one such method that can be used to make sense of large data volumes. At the same time, cluster analysis is known to be imperfect and depends on the choice of algorithms, parameters, and distance measures. Most clustering algorithms don't properly account for ambiguity in the source data, as records are often assigned to discrete clusters, even if an assignment is unclear. While there are metrics and visualization techniques that allow analysts to compare clusterings or to judge cluster quality, there is no comprehensive method that allows analysts to evaluate, compare, and refine cluster assignments based on the source data, derived scores, and contextual data. In this paper, we introduce a method that explicitly visualizes the quality of cluster assignments, allows comparisons of clustering results and enables analysts to manually curate and refine cluster assignments. Our methods are applicable to matrix data clustered with partitional, hierarchical, and fuzzy clustering algorithms. Furthermore, we enable analysts to explore clustering results in context of other data, for example, to observe whether a clustering of genomic data results in a meaningful differentiation in phenotypes. Our methods are integrated into Caleydo StratomeX, a popular, web-based, disease subtype analysis tool. We show in a usage scenario that our approach can reveal ambiguities in cluster assignments and produce improved clusterings that better differentiate genotypes and phenotypes.

  17. Inter-Rater Reliability of Historical Data Collected by Non-Medical Research Assistants and Physicians in Patients with Acute Abdominal Pain

    Directory of Open Access Journals (Sweden)

    Mills, Angela M

    2009-02-01

    Full Text Available OBJECTIVES: In many academic emergency departments (ED, physicians are asked to record clinical data for research that may be time consuming and distracting from patient care. We hypothesized that non-medical research assistants (RAs could obtain historical information from patients with acute abdominal pain as accurately as physicians.METHODS: Prospective comparative study conducted in an academic ED of 29 RAs to 32 resident physicians (RPs to assess inter-rater reliability in obtaining historical information in abdominal pain patients. Historical features were independently recorded on standardized data forms by a RA and RP blinded to each others' answers. Discrepancies were resolved by a third person (RA who asked the patient to state the correct answer on a third questionnaire, constituting the "criterion standard." Inter-rater reliability was assessed using kappa statistics (kappa and percent crude agreement (CrA.RESULTS: Sixty-five patients were enrolled (mean age 43. Of 43 historical variables assessed, the median agreement was moderate (kappa 0.59 [Interquartile range 0.37-0.69]; CrA 85.9% and varied across data categories: initial pain location (kappa 0.61 [0.59-0.73]; CrA 87.7%, current pain location (kappa 0.60 [0.47-0.67]; CrA 82.8%, past medical history (kappa 0.60 [0.48-0.74]; CrA 93.8%, associated symptoms (kappa 0.38 [0.37-0.74]; CrA 87.7%, and aggravating/alleviating factors (kappa 0.09 [-0.01-0.21]; CrA 61.5%. When there was disagreement between the RP and the RA, the RA more often agreed with the criterion standard (64% [55-71%] than the RP (36% [29-45%].CONCLUSION: Non-medical research assistants who focus on clinical research are often more accurate than physicians, who may be distracted by patient care responsibilities, at obtaining historical information from ED patients with abdominal pain.

  18. Inter-Rater Reliability of Cyclotorsion Measurements Using Fundus Photography.

    Science.gov (United States)

    Dysli, Muriel; Kanku, Madeleine; Traber, Ghislaine L

    2018-04-01

    The foveo-papillary angle (FPA) on fundus photographs is the accepted standard for the measurement of ocular cyclotorsion. We assessed the inter-rater reliability of this method in healthy subjects and in patients with trochlear nerve palsies. In this methodological study, fundus photographs of healthy subjects and of patients with trochlear nerve palsies were made with a fundus camera (Zeiss Fundus Camera FF 450 plus, Jena, Germany). Three independent observers measured the FPA on the fundus photographs of all subjects in synedra View (synedra View 16, Version 16.0.0.11, Innsbruck, Austria). One hundred and four eyes of 52 subjects (26 healthy controls and 26 patients) were assessed. The mean FPA of the healthy controls was 5.80 degrees (°) [± 0.44 standard error of the mean (SEM)] compared to 11.55° (± 0.80 SEM) for patients with trochlear nerve palsies. The inter-rater reliability of all measured FPAs showed an intraclass correlation coefficient (ICC) of 0.98 (95% CI 0.97 - 0.98). The inter-rater reliability of objective cyclotorsion measurements using fundus photographs was very high. Georg Thieme Verlag KG Stuttgart · New York.

  19. The reliability of morphometric discriminant functions in determining the sex of Chilean flamingos Phoenicopterus chilensis

    OpenAIRE

    Diego MONTALTI et al

    2012-01-01

    Monomorphic birds cannot be sexed visually and discriminant functions on the basis of external morphological variations are frequently used. Our objective was to evaluate the reliability of sex classification functions created from structural measurements of Chilean flamingos Phoenicopterus chilensis museum skins for the gender assignment of live birds. Five measurements were used to develop four discriminant functions: culmen, bill height and width, tarsus length and middle toe claw. The fun...

  20. Reliability and validity of migraine disability assessment questionnaire-Thai version (Thai-MIDAS).

    Science.gov (United States)

    Seethong, Piman; Nimmannit, Akarin; Chaisewikul, Rungsan; Prayoonwiwat, Naraporn; Chotinaiwattarakul, Wattanachai

    2013-02-01

    To assess the validity and test-retest reliability of a Thai translation of the Migraine Disability Assessment (MIDAS) Questionnaire in Thai patients with migraine. Migraineurs from the Headache Clinic in Siriraj Hospital were recruited and asked to complete a 13-weeks diary and answered the Thai-MIDAS at once. Some participants were asked to provide the 2nd Thai-MIDAS in the next 2 weeks for test-retest reliability. Ninety-three patients had completed the 13-weeks diaries. Age range was 18-58 years with mean 37.69 +/- 9.60 years. All 5 items and the total score of Thai-MIDAS were moderately correlated with data from 13-weeks diary (Spearman's correlation coefficient = 0.32-0.62). The test-retest reliability of the total score of Thai-MIDAS in 30 patients demonstrated a highly reliable degree of intraclass correlation (ICC = 0.76, 95% CI 0.49-0.88). The present study reveals that the Thai-MIDAS has satisfactory validity and reliability in comparison with the original English MIDAS version.

  1. Reliability and validity of the Persian versions of the fear avoidance beliefs questionnaire and Tampa Scale of Kinesiophobia in patients with neck pain.

    Science.gov (United States)

    Askary-Ashtiani, Ahmadreza; Ebrahimi-Takamejani, Ismail; Torkaman, Giti; Amiri, Mohsen; Mousavi, Seyed Javad

    2014-08-15

    Validation of 2 self-report questionnaires. To evaluate the internal consistency, reliability, and construct validity of the Persian versions of the fear avoidance beliefs questionnaire (FABQ) and the Tampa Scale of Kinesiophobia (TSK) in patients with acute and chronic neck pain. The FABQ and TSK are 2 important measures to evaluate fear of pain and fear avoidance beliefs in patients with spinal pain. To date, the psychometric properties of these questionnaires have not been demonstrated in Persian-speaking patients with neck pain in Iran. One hundred sixty-six patients with acute and chronic neck pain participated in the study. The construct validity of the questionnaires was evaluated by measuring convergent and known-groups validity. The visual analogue scale measure of pain, neck disability index, hospital anxiety and depression scale, and the physical (PCS-12) and mental (MCS-12) summary scores of the Short Form health survey (SF-12) were used to test construct validity of the Persian FABQ and TSK. In addition, 50 randomly selected patients with chronic neck pain were asked to complete the questionnaires 48 hours later for the second time. Cronbach α coefficient for the FABQ and TSK in patients with acute and chronic pain was in the range from 0.77 to 0.92 and 0.77 to 0.78, respectively. The Persian FABQ and TSK showed satisfactory test-retest reliability with intraclass correlation coefficient of more than 0.80. There were moderate to strong correlations between the Persian FABQ and TSK scores and the neck disability index (r = 0.44-0.55), Depression subscales of the hospital anxiety and depression scale (r = 0.42-0.48), and PCS-12 (r =-0.34 to -0.62). The Persian FABQ and TSK have acceptable reliability and validity for measuring pain related fear and avoidance beliefs among Persian-speaking patients with acute and chronic neck pain. However, considering the study limitations, the findings should be interpreted with caution. 3.

  2. Validation of the sensitivity of the National Emergency X-Radiography Utilization Study (NEXUS Head computed tomographic (CT decision instrument for selective imaging of blunt head injury patients: An observational study.

    Directory of Open Access Journals (Sweden)

    William R Mower

    2017-07-01

    Full Text Available Clinicians, afraid of missing intracranial injuries, liberally obtain computed tomographic (CT head imaging in blunt trauma patients. Prior work suggests that clinical criteria (National Emergency X-Radiography Utilization Study [NEXUS] Head CT decision instrument [DI] can reliably identify patients with important injuries, while excluding injury, and the need for imaging in many patients. Validating this DI requires confirmation of the hypothesis that the lower 95% confidence limit for its sensitivity in detecting serious injury exceeds 99.0%. A secondary goal of the study was to complete an independent validation and comparison of the Canadian and NEXUS Head CT rules among the subgroup of patients meeting the inclusion and exclusion criteria.We conducted a prospective observational study of the NEXUS Head CT DI in 4 hospital emergency departments between April 2006 and December 2015. Implementation of the rule requires that patients satisfy 8 criteria to achieve "low-risk" classification. Patients are excluded from "low-risk" classification and assigned "high-risk" status if they fail to meet 1 or more criteria. We examined the instrument's performance in assigning "high-risk" status to patients requiring neurosurgical intervention among a cohort of 11,770 blunt head injury patients. The NEXUS Head CT DI assigned high-risk status to 420 of 420 patients requiring neurosurgical intervention (sensitivity, 100.0% [95% confidence interval [CI]: 99.1%-100.0%]. The instrument assigned low-risk status to 2,823 of 11,350 patients who did not require neurosurgical intervention (specificity, 24.9% [95% CI: 24.1%-25.7%]. None of the 2,823 low-risk patients required neurosurgical intervention (negative predictive value [NPV], 100.0% [95% CI: 99.9%-100.0%]. The DI assigned high-risk status to 759 of 767 patients with significant intracranial injuries (sensitivity, 99.0% [95% CI: 98.0%-99.6%]. The instrument assigned low-risk status to 2,815 of 11

  3. Differences in motivation and adherence to a prescribed assignment after face-to-face and online psychoeducation: an experimental study.

    Science.gov (United States)

    Alfonsson, Sven; Johansson, Karin; Uddling, Jonas; Hursti, Timo

    2017-01-26

    Adherence to treatment homework is associated with positive outcomes in behavioral psychotherapy but compliance to assignments is still often moderate. Whether adherence can be predicted by different types of motivation for the task and whether motivation plays different roles in face-to-face compared to online psychotherapy is unknown. If models of motivation, such as Self-determination theory, can be used to predict patients' behavior, it may facilitate further research into homework promotion. The aims of this study were, therefore, to investigate whether motivation variables could predict adherence to a prescribed assignment in face-to-face and online interventions using a psychotherapy analog model. A total of 100 participants were included in this study and randomized to either a face-to-face or online intervention. Participants in both groups received a psychoeducation session and were given an assignment for the subsequent week. The main outcome measurements were self-reported motivation and adherence to the assignment. Participant in the face-to-face condition reported significantly higher levels of motivation and showed higher levels of adherence compared to participants in the online condition. Adherence to the assignment was positively associated with intrinsic motivation and intervention credibility in the whole sample and especially in the online group. This study shows that intrinsic motivation and intervention credibility are strong predictors of adherence to assignments, especially in online interventions. The results indicate that intrinsic motivation may be partly substituted with face-to-face contact with a therapist. It may also be possible to identify patients with low motivation in online interventions who are at risk of dropping out. Methods for making online interventions more intrinsically motivating without increasing external pressure are needed. clinicaltrials.gov NCT02895308 . Retrospectively registered 30 August 2016.

  4. Student generated assignments about electrical circuits in a computer simulation

    NARCIS (Netherlands)

    Vreman-de Olde, Cornelise; de Jong, Anthonius J.M.

    2004-01-01

    In this study we investigated the design of assignments by students as a knowledge-generating activity. Students were required to design assignments for 'other students' in a computer simulation environment about electrical circuits. Assignments consisted of a question, alternatives, and feedback on

  5. Reproducibility and Reliability of the Quality of Life Questionnaire in Patients With Atrial Fibrillation

    Directory of Open Access Journals (Sweden)

    Rita Simone Lopes Moreira

    2016-03-01

    Full Text Available Abstract Background: Studies have shown the impact of atrial fibrillation (AF on the patients' quality of life. Specific questionnaires enable the evaluation of relevant events. We previously developed a questionnaire to assess the quality of life of patients with AF (AFQLQ version 1, which was reviewed in this study, and new domains were added. Objective: To demonstrate the reproducibility of the AFQLQ version 2 (AFQLQ v.2, which included the domains of fatigue, illness perception and well-being. Methods: We applied 160 questionnaires (AFQLQ v.2 and SF-36 to 40 patients, at baseline and 15 days after, to measure inter- and intraobserver reproducibility. The analysis of quality of life stability was determined by test-retest, applying the Bartko intraclass correlation coefficient (ICC. Internal consistency was assessed by Cronbach's alpha test. Results: The total score of the test-retest (n = 40 had an ICC of 0.98 in the AFQLQ v.2, and of 0.94 in the SF36. In assessing the intra- and interobserver reproducibility of the AFQLQ v.2, the ICC reliability was 0.98 and 0.97, respectively. The internal consistency had a Cronbach's alpha coefficient of 0.82, compatible with good agreement of the AFQLQ v.2. Conclusion: The AFQLQ v.2 performed better than its previous version. Similarly, the domains added contributed to make it more comprehensive and robust to assess the quality of life of patients with AF.

  6. High-reliability health care: getting there from here.

    Science.gov (United States)

    Chassin, Mark R; Loeb, Jerod M

    2013-09-01

    Despite serious and widespread efforts to improve the quality of health care, many patients still suffer preventable harm every day. Hospitals find improvement difficult to sustain, and they suffer "project fatigue" because so many problems need attention. No hospitals or health systems have achieved consistent excellence throughout their institutions. High-reliability science is the study of organizations in industries like commercial aviation and nuclear power that operate under hazardous conditions while maintaining safety levels that are far better than those of health care. Adapting and applying the lessons of this science to health care offer the promise of enabling hospitals to reach levels of quality and safety that are comparable to those of the best high-reliability organizations. We combined the Joint Commission's knowledge of health care organizations with knowledge from the published literature and from experts in high-reliability industries and leading safety scholars outside health care. We developed a conceptual and practical framework for assessing hospitals' readiness for and progress toward high reliability. By iterative testing with hospital leaders, we refined the framework and, for each of its fourteen components, defined stages of maturity through which we believe hospitals must pass to reach high reliability. We discovered that the ways that high-reliability organizations generate and maintain high levels of safety cannot be directly applied to today's hospitals. We defined a series of incremental changes that hospitals should undertake to progress toward high reliability. These changes involve the leadership's commitment to achieving zero patient harm, a fully functional culture of safety throughout the organization, and the widespread deployment of highly effective process improvement tools. Hospitals can make substantial progress toward high reliability by undertaking several specific organizational change initiatives. Further research

  7. On pole structure assignment in linear systems

    Czech Academy of Sciences Publication Activity Database

    Loiseau, J.-J.; Zagalak, Petr

    2009-01-01

    Roč. 82, č. 7 (2009), s. 1179-1192 ISSN 0020-7179 R&D Projects: GA ČR(CZ) GA102/07/1596 Institutional research plan: CEZ:AV0Z10750506 Keywords : linear systems * linear state feedback * pole structure assignment Subject RIV: BC - Control Systems Theory Impact factor: 1.124, year: 2009 http://library.utia.cas.cz/separaty/2009/AS/zagalak-on pole structure assignment in linear systems.pdf

  8. Suprahyoid Muscle Complex: A Reliable Neural Assessment Tool For Dysphagia?

    DEFF Research Database (Denmark)

    Kothari, Mohit; Stubbs, Peter William; Pedersen, Asger Roer

    be a non-invasive reliable neural assessment tool for patients with dysphagia. Objective: To investigate the possibility of using the suprahyoid muscle complex (SMC) using surface electromyography (sEMG) to assess changes to neural pathways by determining the reliability of measurements in healthy...

  9. Personnel shift assignment: Existence conditions and network models

    NARCIS (Netherlands)

    van den Berg, Jeroen P.; van den Berg, J.P.; Panton, David M.

    1994-01-01

    The personnel scheduling problem is known to be a five-stage process in which the final stage involves the assignment of shifts to the days worked in the schedule. This paper discusses the existence conditions for both continuous and forward rotating shift assignments and heuristic network

  10. Reproducibility of tender point examination in chronic low back pain patients as measured by intrarater and inter-rater reliability and agreement

    DEFF Research Database (Denmark)

    Jensen, Ole Kudsk; Callesen, Jacob; Nielsen, Merete Graakjaer

    2013-01-01

    back examination and return-to-work intervention, 43 and 39 patients, respectively (18 women, 46%) entered and completed the study. MAIN OUTCOME MEASURES: The reliability was estimated by the intraclass correlation coefficient (ICC), and agreement was calculated for up to ±3 TPs. Furthermore......, the smallest detectable difference was calculated. RESULTS: TP examination was performed twice by two consultants in rheumatology and rehabilitation at 20 min intervals and repeated 1 week later. Intrarater reliability in the more and less experienced rater was ICC 0.84 (95% CI 0.69 to 0.98) and 0.72 (95% CI 0.......49 to 0.95), respectively. The figures for inter-rater reliability were intermediate between these figures. In more than 70% of the cases, the raters agreed within ±3 TPs in both men and women and between test days. The smallest detectable difference between raters was 5, and for the more and less...

  11. 75 FR 55355 - Delegation of Authority and Assignment of Responsibility

    Science.gov (United States)

    2010-09-10

    ... DEPARTMENT OF LABOR Office of the Secretary Delegation of Authority and Assignment of Responsibility Secretary's Order 4-2010 Subject: Delegation of Authority and Assignment of Responsibility to the... delegations and assignments in full force and effect, except as expressly modified herein. 4. Delegation of...

  12. Number of test trials needed for performance stability and interrater reliability of the one leg stand test in patients with a major non-traumatic lower limb amputation

    DEFF Research Database (Denmark)

    Kristensen, Morten Tange; Nielsen, Anni Østergaard; Madsen Topp, Ulla

    2014-01-01

    Balance is beneficial for daily functioning of patients with a lower limb amputation and sometimes assessed by the one-leg stand test (OLST). The aims of the study were to examine (1) the number of trials needed to achieve performance stability, (2) the interrater reliability of the OLST in patie......Balance is beneficial for daily functioning of patients with a lower limb amputation and sometimes assessed by the one-leg stand test (OLST). The aims of the study were to examine (1) the number of trials needed to achieve performance stability, (2) the interrater reliability of the OLST...... in patients with a major non-traumatic lower limb amputation, and (3) to provide a test procedure....

  13. Staff assignment practices in nursing homes: review of the literature.

    Science.gov (United States)

    Rahman, Anna; Straker, Jane K; Manning, Lydia

    2009-01-01

    Consistent assignment, whereby nursing home staff members, particularly certified nurse aides, are assigned to the same residents on most shifts, is increasingly viewed as a cornerstone of culture change in nursing homes. It has been advocated as a best-care model that increases residents' quality of life while contributing to a more stable frontline staff. Given these potential benefits, consistent assignment is now widely viewed as superior to rotating assignment, an alternative staffing model that aims to distribute care burden more fairly among staff and ensure that workers are familiar with most residents. Despite favorable anecdotal reports about the benefits of consistent assignment, the research literature reports mixed and sometimes contradictory findings for this staffing practice. This article reviews the research pertaining to staff assignment practices in nursing homes. Reviewed here are 13 reports on experimental trials (6 reports), evaluation research (4 reports), and nursing home surveys (3 reports). The review reveals broad diversity in staffing practices and raises questions that challenge popular assumptions about consistent assignment. The article closes with a discussion of the research, policy, and practice implications of the research findings.

  14. 75 FR 55354 - Delegation of Authority and Assignment of Responsibilities

    Science.gov (United States)

    2010-09-10

    ... DEPARTMENT OF LABOR Office of the Secretary Delegation of Authority and Assignment of Responsibilities Secretary's Order 3-2010 Subject: Delegation of Authority and Assignment of Responsibilities to... Secretary to enforce sections 18A and 18B of the FLSA. 4. Delegation of Authority and Assignment of...

  15. Quality Control Test for Sequence-Phenotype Assignments

    Science.gov (United States)

    Ortiz, Maria Teresa Lara; Rosario, Pablo Benjamín Leon; Luna-Nevarez, Pablo; Gamez, Alba Savin; Martínez-del Campo, Ana; Del Rio, Gabriel

    2015-01-01

    Relating a gene mutation to a phenotype is a common task in different disciplines such as protein biochemistry. In this endeavour, it is common to find false relationships arising from mutations introduced by cells that may be depurated using a phenotypic assay; yet, such phenotypic assays may introduce additional false relationships arising from experimental errors. Here we introduce the use of high-throughput DNA sequencers and statistical analysis aimed to identify incorrect DNA sequence-phenotype assignments and observed that 10–20% of these false assignments are expected in large screenings aimed to identify critical residues for protein function. We further show that this level of incorrect DNA sequence-phenotype assignments may significantly alter our understanding about the structure-function relationship of proteins. We have made available an implementation of our method at http://bis.ifc.unam.mx/en/software/chispas. PMID:25700273

  16. "An Investigation Into The Interrater Reliability Of The Modified Ashworth Scale In The Assessment Of Muscle Spasticity In Hemiplegic Patients "

    Directory of Open Access Journals (Sweden)

    N. Nokhostin-Ansari

    2006-06-01

    Full Text Available Background and Aim: Spasticity is a velocity-dependent increase in tonic stretch reflexes (muscle tone with exaggerated tendon jerks, resulting from hyperexcitability of the stretch reflex. The measurement of spasticity is necessary to determine the effect of treatments. The Modified Ashworth Scale is the most widely used method for assessing muscle spasticity in clinical practice and research. The purpose of this study was to investigate the interrater reliability of Modified Ashworth Scale in hemiplegic patients. Materials and Methods: Thirty subjects (16 males, 14 females with a mean age of 59.40 (SD =14.013 recruited. Shoulder adductor , elbow flexor , wrist dorsiflexor , hip adductor , knee extensor and ankle plantarflexor on the hemiplegic side were tested by two physiotherapists. Results: In the upper limb, the interrater reliability for shoulder adductor and elbow flexor muscles was fair (0.372 and 0.369, respectively. The reliability for the wrist flexors was good (0.612. The difference in Kappa value for the proximal muscle (shoulder adductor; 0.372 and the distal muscle (wrist flexor; 0.612 was significant (²X=33.87, df=1, p0.05. The mean value for the upper limb (0.505 and the lower limb (0,.516 was not significantly different (²X=0.1407, df=1, p>0.05. Conclusion: The interrater reliability of Modified Ashworth Scale was not good . The limb, upper or lower, had no significant effect on the reliability. In the upper limb, the reliability for the proximal and distal muscle was significantly different. However. The difference in the lower limb was not significant.When using the scale, one should consider it's limitation.

  17. 25 CFR 225.33 - Assignment of minerals agreements.

    Science.gov (United States)

    2010-04-01

    ... 25 Indians 1 2010-04-01 2010-04-01 false Assignment of minerals agreements. 225.33 Section 225.33 Indians BUREAU OF INDIAN AFFAIRS, DEPARTMENT OF THE INTERIOR ENERGY AND MINERALS OIL AND GAS, GEOTHERMAL, AND SOLID MINERALS AGREEMENTS Minerals Agreements § 225.33 Assignment of minerals agreements. An...

  18. Automating Formative and Summative Feedback for Individualised Assignments

    Science.gov (United States)

    Hamilton, Ian Robert

    2009-01-01

    Purpose: The purpose of this paper is to report on the rationale behind the use of a unique paper-based individualised accounting assignment, which automated the provision to students of immediate formative and timely summative feedback. Design/methodology/approach: As students worked towards completing their assignment, the package provided…

  19. submission of art studio-based assignments: students experience

    African Journals Online (AJOL)

    PUBLICATIONS1

    are reluctant to complete their studio assignments on time are critically ... tative and qualitative data, derived from survey and interviews were used to ... is therefore exploratory and studio based. It ... mogenous group of students who report pro- ... Assignment management .... The analyses in this study are based on data.

  20. Heuristic for Task-Worker Assignment with Varying Learning Slopes

    Directory of Open Access Journals (Sweden)

    Wipawee Tharmmaphornphilas

    2010-04-01

    Full Text Available Fashion industry has variety products, so the multi-skilled workers are required to improve flexibility in production and assignment. Generally the supervisor will assign task to the workers based on skill and skill levels of worker. Since in fashion industry new product styles are launched more frequently and the order size tends to be smaller, the workers always learn when the raw material and the production process changes. Consequently they require less time to produce the succeeding units of a task based on their learning ability. Since the workers have both experience and inexperience workers, so each worker has different skill level and learning ability. Consequently, the assignment which assumed constant skill level is not proper to use. This paper proposes a task-worker assignment considering worker skill levels and learning abilities. Processing time of each worker changes along production period due to a worker learning ability. We focus on a task-worker assignment in a fashion industry where tasks are ordered in series; the number of tasks is greater than the number of workers. Therefore, workers can perform multiple assignments followed the precedence restriction as an assembly line balancing problem. The problem is formulated in an integer linear programming model with objective to minimize makespan. A heuristic is proposed to determine the lower bound (LB and the upper bound (UB of the problem and the best assignment is determined. The performance of the heuristic method is tested by comparing quality of solution and computational time to optimal solutions.

  1. Feasibility, reliability and validity of a questionnaire on healthcare consumption and productivity loss in patients with a psychiatric disorder (TiC-P)

    NARCIS (Netherlands)

    C.A.M. Bouwmans-Frijters (Clazien); K.T. de Jong (Kim); R. Timman (Reinier); M.C. Zijlstra-Vlasveld (Moniek); C.M. van der Feltz-Cornelis (Christina); S.S. Tan (Siok Swan); L. van Hakkaart-van Roijen (Leona)

    2013-01-01

    textabstractBackground: Patient self-report allows collecting comprehensive data for the purpose of performing economic evaluations. The aim of the current study was to assess the feasibility, reliability and a part of the construct validity of a commonly applied questionnaire on healthcare

  2. Validity and reliability of isometric, isokinetic and isoinertial modalities for the assessment of quadriceps muscle strength in patients with total knee arthroplasty.

    Science.gov (United States)

    Lienhard, K; Lauermann, S P; Schneider, D; Item-Glatthorn, J F; Casartelli, N C; Maffiuletti, N A

    2013-12-01

    Reliability of isometric, isokinetic and isoinertial modalities for quadriceps strength evaluation, and the relation between quadriceps strength and physical function was investigated in 29 total knee arthroplasty (TKA) patients, with an average age of 63 years. Isometric maximal voluntary contraction torque, isokinetic peak torque, and isoinertial one-repetition maximum load of the involved and uninvolved quadriceps were evaluated as well as objective (walking parameters) and subjective physical function (WOMAC). Reliability was good and comparable for the isometric, isokinetic, and isoinertial strength outcomes on both sides (intraclass correlation coefficient range: 0.947-0.966; standard error of measurement range: 5.1-9.3%). Involved quadriceps strength was significantly correlated to walking speed (r range: 0.641-0.710), step length (r range: 0.685-0.820) and WOMAC function (r range: 0.575-0.663), independent from the modality (P strength was also significantly correlated to walking speed (r range: 0.413-0.539), step length (r range: 0.514-0.608) and WOMAC function (r range: 0.374-0.554) (P 0.05). In conclusion, isometric, isokinetic, and isoinertial modalities ensure valid and reliable assessment of quadriceps muscle strength in TKA patients. Copyright © 2013 Elsevier Ltd. All rights reserved.

  3. Reliability, Validity, and Optimal Cutoff Score of the Montreal Cognitive Assessment (Changsha Version) in Ischemic Cerebrovascular Disease Patients of Hunan Province, China

    Science.gov (United States)

    Tu, Qiu-yun; Jin, Hui; Ding, Bin-rong; Yang, Xia; Lei, Zeng-hui; Bai, Song; Zhang, Ying-dong; Tang, Xiang-qi

    2013-01-01

    Background/Aims The goal of this study was to examine the reliability and validity of the Changsha version of the Montreal Cognitive Assessment (MoCA-CS) in ischemic cerebrovascular disease patients of Hunan Province, China, and to explore the optimal cutoff score for detecting vascular cognitive impairment-no dementia (VCI-ND) and vascular dementia (VD). Methods Three hundred and thirty-eight ischemic cerebrovascular disease patients (131 with normal cognition, 111 with VCI-ND, and 96 with VD) and 132 healthy controls were recruited. All participants accepted examination by the MoCA-CS, Mini-Mental State Examination (MMSE), and other related scales. A detailed neuropsychological battery was used for making a final cognitive diagnosis. SPSS 16.0 statistical software was used for reliability, validity examination, and optimal cutoff score detection. Results Cronbach's α of the MoCA-CS was 0.884, and test-retest and interrater reliability of the MoCA-CS were 0.966 and 0.926, respectively. MoCA-CS scores were highly correlated with MMSE scores (r = 0.867) and simplified intelligence quotients (r = 0.822). The results indicate that 1 point should be added for subjects with less than 6 years of education, and that the optimal cutoff score for detecting VCI-ND is 26/27 (sensitivity 96.1%, specificity 75.6%), whereas the optimal cutoff score for detecting VD is 16/17 (sensitivity 92.7%, specificity 96.3%). Conclusion The MoCA-CS has good reliability and validity, and is a useful cognitive screening instrument for detecting VCI in the Chinese population. PMID:23637698

  4. Reliability, Validity, and Optimal Cutoff Score of the Montreal Cognitive Assessment (Changsha Version in Ischemic Cerebrovascular Disease Patients of Hunan Province, China

    Directory of Open Access Journals (Sweden)

    Qiu-yun Tu

    2013-02-01

    Full Text Available Background/Aims: The goal of this study was to examine the reliability and validity of the Changsha version of the Montreal Cognitive Assessment (MoCA-CS in ischemic cerebrovascular disease patients of Hunan Province, China, and to explore the optimal cutoff score for detecting vascular cognitive impairment-no dementia (VCI-ND and vascular dementia (VD. Methods: Three hundred and thirty-eight ischemic cerebrovascular disease patients (131 with normal cognition, 111 with VCI-ND, and 96 with VD and 132 healthy controls were recruited. All participants accepted examination by the MoCA-CS, Mini-Mental State Examination (MMSE, and other related scales. A detailed neuropsychological battery was used for making a final cognitive diagnosis. SPSS 16.0 statistical software was used for reliability, validity examination, and optimal cutoff score detection. Results: Cronbach’s α of the MoCA-CS was 0.884, and test-retest and interrater reliability of the MoCA-CS were 0.966 and 0.926, respectively. MoCA-CS scores were highly correlated with MMSE scores (r = 0.867 and simplified intelligence quotients (r = 0.822. The results indicate that 1 point should be added for subjects with less than 6 years of education, and that the optimal cutoff score for detecting VCI-ND is 26/27 (sensitivity 96.1%, specificity 75.6%, whereas the optimal cutoff score for detecting VD is 16/17 (sensitivity 92.7%, specificity 96.3%. Conclusion: The MoCA-CS has good reliability and validity, and is a useful cognitive screening instrument for detecting VCI in the Chinese population.

  5. Assignment Procedures in the Air Force Procurement Management Information System.

    Science.gov (United States)

    Ward, Joe H., Jr.; And Others

    An overview is presented of the procedure for offering jobs in the Air Force Procurement Management Information System (PROMIS), an assignment system which makes possible the use of human resources research findings to improve individual personnel assignments. A general framework for viewing personnel assignment systems is presented; then job…

  6. A property of assignment type mixed integer linear programming problems

    NARCIS (Netherlands)

    Benders, J.F.; van Nunen, J.A.E.E.

    1982-01-01

    In this paper we will proof that rather tight upper bounds can be given for the number of non-unique assignments that are achieved after solving the linear programming relaxation of some types of mixed integer linear assignment problems. Since in these cases the number of splitted assignments is

  7. 41 CFR 105-8.152 - Program accessibility: Assignment of space.

    Science.gov (United States)

    2010-07-01

    ... 41 Public Contracts and Property Management 3 2010-07-01 2010-07-01 false Program accessibility: Assignment of space. 105-8.152 Section 105-8.152 Public Contracts and Property Management Federal Property...-8.152 Program accessibility: Assignment of space. (a) When GSA assigns or reassigns space to an...

  8. Reliability of the exercise ECG in detecting silent ischemia in patients with prior myocardial infarction

    International Nuclear Information System (INIS)

    Yamagishi, Takashi; Matsuda, Yasuo; Satoh, Akira

    1991-01-01

    To assess the reliability of the exercise ECG in detecting silent ischemia, ECG results were compared with those of stress-redistribution thallium-201 single-photon emission computed tomography (SPECT) in 116 patients with prior myocardial infarction and in 20 normal subjects used as a control. The left ventricle (LV) was divided into 20 segmental images, which were scored blindly on a 5-point scale. The redistribution score was defined as thallium defect score of exercise subtracted by that of redistribution image and was used as a measure of amount of ischemic but viable myocardium. The upper limit of normal redistribution score (=4.32) was defined as mean+2 standard deviations derived from 20 normal subjects. Of 116 patients, 47 had the redistribution score above the normal range. Twenty-five (53%) of the 47 patients showed positive ECG response. Fourteen (20%) of the 69 patients, who had the normal redistribution score, showed positive ECG response. Thus, the ECG response had a sensitivity of 53% and a specificity of 80% in detecting transient ischemia. Furthermore, the 116 patients were subdivided into 4 groups according to the presence or absence of chest pain and ECG change during exercise. Fourteen patients showed both chest pain and ECG change and all these patients had the redistribution score above the normal range. Twenty-five patients showed ECG change without chest pain and 11 (44%) of the 25 patients had the abnormal redistribution. Three (43%) of 7 patients who showed chest pain without ECG change had the abnormal redistribution score. Of 70 patients who had neither chest pain nor ECG change, 19 (27%) had the redistribution score above the normal range. Thus, limitations exist in detecting silent ischemia by ECG in patients with a prior myocardial infarction, because the ECG response to the exercise test may have a low degree of sensitivity and a high degree of false positive and false negative results in detecting silent ischemia. (author)

  9. Scaffolding Assignments and Activities for Undergraduate Research Methods

    Science.gov (United States)

    Fisher, Sarah; Justwan, Florian

    2018-01-01

    This article details assignments and lessons created for and tested in research methods courses at two different universities, a large state school and a small liberal arts college. Each assignment or activity utilized scaffolding. Students were asked to push beyond their comfort zone while utilizing concrete and/or creative examples,…

  10. Validation and reliability of a Behcet's Syndrome Activity Scale in Korea.

    Science.gov (United States)

    Choi, Hyo Jin; Seo, Mi Ryoung; Ryu, Hee Jung; Baek, Han Joo

    2016-01-01

    We prepared a cross-cultural adaptation of the Behcet's Syndrome Activity Scale (BSAS) and evaluated its reliability and validity in Korea. Fifty patients with Behcet's disease (BD) who attended the Rheumatology Clinic of Gachon University Gil Medical Center were included in this study. The first BSAS questionnaire was administered at each clinic visit, and the second questionnaire was completed at home within 24 hours of the visit. A Behcet's Disease Current Activity Form (BDCAF) and a Behcet's Disease Quality of Life (BDQOL) form were also given to patients. The test-retest reliability was analyzed by intraclass correlation coefficients (ICC). To assess the validity, the total BSAS score was compared with the BDCAF score, the patient/physician global assessment, and the BDQOL by Spearman rank correlation. Twelve males and 38 females were enrolled. The mean age was 48.5 years and the mean disease duration was 6.7 years. Thirty-eight patients (76.0%) returned the questionnaire by mail. For the test-retest reliability, the two assessments were significantly correlated on all 10 items of the BSAS questionnaire (p < 0.05) and the total BSAS score (ICC, 0.925; p < 0.001). The total BSAS score was statistically correlated with the BDQOL, BDCAF, and patient/physician global assessment (p < 0.01). The Korean version of BSAS is a reliable and valid instrument to measure BD activity.

  11. Socially-assigned race, healthcare discrimination and preventive healthcare services.

    Directory of Open Access Journals (Sweden)

    Tracy Macintosh

    Full Text Available Race and ethnicity, typically defined as how individuals self-identify, are complex social constructs. Self-identified racial/ethnic minorities are less likely to receive preventive care and more likely to report healthcare discrimination than self-identified non-Hispanic whites. However, beyond self-identification, these outcomes may vary depending on whether racial/ethnic minorities are perceived by others as being minority or white; this perception is referred to as socially-assigned race.To examine the associations between socially-assigned race and healthcare discrimination and receipt of selected preventive services.Cross-sectional analysis of the 2004 Behavioral Risk Factor Surveillance System "Reactions to Race" module. Respondents from seven states and the District of Columbia were categorized into 3 groups, defined by a composite of self-identified race/socially-assigned race: Minority/Minority (M/M, n = 6,837, Minority/White (M/W, n = 929, and White/White (W/W, n = 25,913. Respondents were 18 years or older, with 61.7% under age 60; 51.8% of respondents were female. Measures included reported healthcare discrimination and receipt of vaccinations and cancer screenings.Racial/ethnic minorities who reported being socially-assigned as minority (M/M were more likely to report healthcare discrimination compared with those who reported being socially-assigned as white (M/W (8.9% vs. 5.0%, p = 0.002. Those reporting being socially-assigned as white (M/W and W/W had similar rates for past-year influenza (73.1% vs. 74.3% and pneumococcal (69.3% vs. 58.6% vaccinations; however, rates were significantly lower among M/M respondents (56.2% and 47.6%, respectively, p-values<0.05. There were no significant differences between the M/M and M/W groups in the receipt of cancer screenings.Racial/ethnic minorities who reported being socially-assigned as white are more likely to receive preventive vaccinations and less likely to report

  12. Effects of 3,4-Methylenedioxymethamphetamine on Patient Utterances in a Psychotherapeutic Setting.

    Science.gov (United States)

    Corey, Vicka Rael; Pisano, Vincent D; Halpern, John H

    2016-07-01

    3,4-Methylenedioxymethamphetamine (MDMA) administered as an adjunct to talk therapy influences patient speech content and increases improvement in treatment-resistant posttraumatic stress disorder (PTSD). Data came from the recordings of Mithoefer et al. (2011). In the third therapeutic session studied, patients were assigned, double blind, to an MDMA or a placebo group. Condition-blind scorers listened to therapy recordings and scored utterances where patients initiated topics that were empathic (regarding others' emotions), entactic (requesting or appreciating physical touch), or ensuic (describing a change in their sense of themselves). Patients who received MDMA produced high levels of ensuic, empathic, and entactic utterances compared with those who received the placebo. Interrater discourse scoring was reliable. The relationship between the number of scored utterances and the Clinician Administered PTSD Scale scores measuring PTSD severity after the treatment was significant, and reanalysis grouped bimodally into "many" or "few" such utterances remained significant. MDMA assisted these patients in having meaningful and disorder-resolving thoughts and discourse in talk therapy.

  13. Validity and Reliability of the Turkish Chronic Pain Acceptance Questionnaire

    Science.gov (United States)

    Akmaz, Hazel Ekin; Uyar, Meltem; Kuzeyli Yıldırım, Yasemin; Akın Korhan, Esra

    2018-05-29

    Pain acceptance is the process of giving up the struggle with pain and learning to live a worthwhile life despite it. In assessing patients with chronic pain in Turkey, making a diagnosis and tracking the effectiveness of treatment is done with scales that have been translated into Turkish. However, there is as yet no valid and reliable scale in Turkish to assess the acceptance of pain. To validate a Turkish version of the Chronic Pain Acceptance Questionnaire developed by McCracken and colleagues. Methodological and cross sectional study. A simple randomized sampling method was used in selecting the study sample. The sample was composed of 201 patients, more than 10 times the number of items examined for validity and reliability in the study, which totaled 20. A patient identification form, the Chronic Pain Acceptance Questionnaire, and the Brief Pain Inventory were used to collect data. Data were collected by face-to-face interviews. In the validity testing, the content validity index was used to evaluate linguistic equivalence, content validity, construct validity, and expert views. In reliability testing of the scale, Cronbach’s α coefficient was calculated, and item analysis and split-test reliability methods were used. Principal component analysis and varimax rotation were used in factor analysis and to examine factor structure for construct concept validity. The item analysis established that the scale, all items, and item-total correlations were satisfactory. The mean total score of the scale was 21.78. The internal consistency coefficient was 0.94, and the correlation between the two halves of the scale was 0.89. The Chronic Pain Acceptance Questionnaire, which is intended to be used in Turkey upon confirmation of its validity and reliability, is an evaluation instrument with sufficient validity and reliability, and it can be reliably used to examine patients’ acceptance of chronic pain.

  14. The Presentation Assignment: Creating Learning Opportunities for Diverse Student Populations.

    Science.gov (United States)

    Spencer, Brenda H.; Bartle-Angus, Kathryn

    2000-01-01

    Finds the presentation assignment to be an effective method of providing students with the opportunity to apply the literacy skills they are learning in ways that are personally meaningful. Describes the presentation assignment framework and provides an example of an assignment that required students to analyze and interpret works of literature…

  15. Visual words assignment via information-theoretic manifold embedding.

    Science.gov (United States)

    Deng, Yue; Li, Yipeng; Qian, Yanjun; Ji, Xiangyang; Dai, Qionghai

    2014-10-01

    Codebook-based learning provides a flexible way to extract the contents of an image in a data-driven manner for visual recognition. One central task in such frameworks is codeword assignment, which allocates local image descriptors to the most similar codewords in the dictionary to generate histogram for categorization. Nevertheless, existing assignment approaches, e.g., nearest neighbors strategy (hard assignment) and Gaussian similarity (soft assignment), suffer from two problems: 1) too strong Euclidean assumption and 2) neglecting the label information of the local descriptors. To address the aforementioned two challenges, we propose a graph assignment method with maximal mutual information (GAMI) regularization. GAMI takes the power of manifold structure to better reveal the relationship of massive number of local features by nonlinear graph metric. Meanwhile, the mutual information of descriptor-label pairs is ultimately optimized in the embedding space for the sake of enhancing the discriminant property of the selected codewords. According to such objective, two optimization models, i.e., inexact-GAMI and exact-GAMI, are respectively proposed in this paper. The inexact model can be efficiently solved with a closed-from solution. The stricter exact-GAMI nonparametrically estimates the entropy of descriptor-label pairs in the embedding space and thus leads to a relatively complicated but still trackable optimization. The effectiveness of GAMI models are verified on both the public and our own datasets.

  16. Patient Factors Used by Pediatricians to Assign Asthma Treatment

    Science.gov (United States)

    Okelo, Sande O.; Patino, Cecilia M.; Riekert, Kristin A.; Merriman, Barry; Bilderback, Andrew; Hansel, Nadia N.; Thompson, Kathy; Thompson, Jennifer; Quartey, Ruth; Rand, Cynthia S.; Diette, Gregory B.

    2009-01-01

    OBJECTIVE Although asthma is often inappropriately treated in children, little is known about what information pediatricians use to adjust asthma therapy. The purpose of this work was to assess the importance of various dimensions of patient asthma status as the basis of pediatrician treatment decisions. PATIENTS AND METHODS We conducted a cross-sectional, random-sample survey, between November 2005 and May 2006, of 500 members of the American Academy of Pediatrics using standardized case vignettes. Vignettes varied in regard to (1) acute health care use (hospitalized 6 months ago), (2) bother (parent bothered by the child’s asthma status), (3) control (frequency of symptoms and albuterol use), (4) direction (qualitative change in symptoms), and (5) wheezing during physical examination. Our primary outcome was the proportion of pediatricians who would adjust treatment in the presence or absence of these 5 factors. RESULTS Physicians used multiple dimensions of asthma status other than symptoms to determine treatment. Pediatricians were significantly more likely to increase treatment for a recently hospitalized patient (45% vs 18%), a bothered parent (67% vs 18%), poorly controlled symptoms (4–5 times per week; 100% vs 18%), or if there was wheezing on examination (45% vs 18%) compared with patients who only had well-controlled symptoms. Pediatricians were significantly less likely to decrease treatment for a child with well-controlled symptoms and recent hospitalization (28%), parents who reported being bothered (43%), or a child whose symptoms had worsened since the last doctor visit (10%) compared with children with well-controlled symptoms alone. CONCLUSIONS Pediatricians treat asthma on the basis of multiple dimensions of asthma status, including hospitalization, bother, symptom frequency, direction, and wheezing but use these factors differently to increase and decrease treatment. Tools that systematically assess multiple dimensions of asthma may be useful

  17. Contact replacement for NMR resonance assignment.

    Science.gov (United States)

    Xiong, Fei; Pandurangan, Gopal; Bailey-Kellogg, Chris

    2008-07-01

    Complementing its traditional role in structural studies of proteins, nuclear magnetic resonance (NMR) spectroscopy is playing an increasingly important role in functional studies. NMR dynamics experiments characterize motions involved in target recognition, ligand binding, etc., while NMR chemical shift perturbation experiments identify and localize protein-protein and protein-ligand interactions. The key bottleneck in these studies is to determine the backbone resonance assignment, which allows spectral peaks to be mapped to specific atoms. This article develops a novel approach to address that bottleneck, exploiting an available X-ray structure or homology model to assign the entire backbone from a set of relatively fast and cheap NMR experiments. We formulate contact replacement for resonance assignment as the problem of computing correspondences between a contact graph representing the structure and an NMR graph representing the data; the NMR graph is a significantly corrupted, ambiguous version of the contact graph. We first show that by combining connectivity and amino acid type information, and exploiting the random structure of the noise, one can provably determine unique correspondences in polynomial time with high probability, even in the presence of significant noise (a constant number of noisy edges per vertex). We then detail an efficient randomized algorithm and show that, over a variety of experimental and synthetic datasets, it is robust to typical levels of structural variation (1-2 AA), noise (250-600%) and missings (10-40%). Our algorithm achieves very good overall assignment accuracy, above 80% in alpha-helices, 70% in beta-sheets and 60% in loop regions. Our contact replacement algorithm is implemented in platform-independent Python code. The software can be freely obtained for academic use by request from the authors.

  18. Reliable volumetry of the cervical spinal cord in MS patient follow-up data with cord image analyzer (Cordial).

    Science.gov (United States)

    Amann, Michael; Pezold, Simon; Naegelin, Yvonne; Fundana, Ketut; Andělová, Michaela; Weier, Katrin; Stippich, Christoph; Kappos, Ludwig; Radue, Ernst-Wilhelm; Cattin, Philippe; Sprenger, Till

    2016-07-01

    Spinal cord (SC) atrophy is an important contributor to the development of disability in many neurological disorders including multiple sclerosis (MS). To assess the spinal cord atrophy in clinical trials and clinical practice, largely automated methods are needed due to the sheer amount of data. Moreover, using these methods in longitudinal trials requires them to deliver highly reliable measurements, enabling comparisons of multiple data sets of the same subject over time. We present a method for SC volumetry using 3D MRI data providing volume measurements for SC sections of fixed length and location. The segmentation combines a continuous max flow approach with SC surface reconstruction that locates the SC boundary based on image voxel intensities. Two cutting planes perpendicular to the SC centerline are determined based on predefined distances to an anatomical landmark, and the cervical SC volume (CSCV) is then calculated in-between these boundaries. The development of the method focused on its application in MRI follow-up studies; the method provides a high scan-rescan reliability, which was tested on healthy subject data. Scan-rescan reliability coefficients of variation (COV) were below 1 %, intra- and interrater COV were even lower (0.1-0.2 %). To show the applicability in longitudinal trials, 3-year follow-up data of 48 patients with a progressive course of MS were assessed. In this cohort, CSCV loss was the only significant predictor of disability progression (p = 0.02). We are, therefore, confident that our method provides a reliable tool for SC volumetry in longitudinal clinical trials.

  19. Evaluating the Validity and Reliability of the Beliefs About Medicines Questionnaire in Low-Income, Spanish-Speaking Patients With Diabetes in the United States.

    Science.gov (United States)

    Jimenez, Krystal; Vargas, Cristina; Garcia, Karla; Guzman, Herlinda; Angulo, Marco; Billimek, John

    2017-02-01

    Purpose The purpose of this study was to examine the reliability and validity of a Spanish version of the Beliefs about Medicines Questionnaire (BMQ) as a measure to evaluate beliefs about medications and to differentiate adherent from nonadherent patients among low-income Latino patients with diabetes in the United States. Methods Seventy-three patients were administered the BMQ and surveyed for evidence of medication nonadherence. Internal consistency of the BMQ was assessed by Cronbach's alpha along with performing a confirmatory factor analysis. Criterion validity was assessed by comparing mean scores on 3 subscales of the BMQ (General Overuse, General Harm, and Specific Necessity-Concerns difference score) between adherent patients and patients reporting nonadherence for 3 different reasons (unintentional nonadherence, cost-related nonadherence, and nonadherence due to reasons other than cost) using independent samples t tests. Results The BMQ is a reliable instrument to examine beliefs about medications in this Spanish-speaking population. Construct validity testing shows nearly identical factor loading as the original construct map. General Overuse scores were significantly more negative for patients reporting each reason for nonadherence compared with their adherent counterparts. Necessity-Concerns difference scores were significantly more negative for patients reporting nonadherence for reasons other than cost compared with those who did not report this reason for nonadherence. Conclusion The Spanish version of the BMQ is appropriate to assess beliefs about medications in Latino patients with type 2 diabetes in the United States and may help identify patients who become nonadherent to medications for reasons other than out-of-pocket costs.

  20. The Effect of Patient Characteristics and Sleep Quality on Visual Field Performance Reliability

    Directory of Open Access Journals (Sweden)

    Swarup S. Swaminathan

    2018-01-01

    Full Text Available Purpose. To investigate the association of automated visual field (VF reliability indices (false positive [FP], false negative [FN], and fixation loss [FL] and sleep quality, VF experience, and age. Methods. Prospective, cross-sectional study. Adult patients (age ≥ 18 years completing automated VF testing were invited to participate. Baseline participant characteristics were obtained, and all participants were asked to complete the Pittsburgh Sleep Quality Index (PSQI questionnaire. Nonparametric Spearman correlations and logistical regression models were performed. Results. 63 patients were enrolled. Lower PSQI score was correlated with higher percentage (% FL in the right eye (p=0.03. Fewer prior VF was significantly correlated with higher %FP in the right eye (p=0.008. Older age was significantly correlated with higher %FN in the left eye (p=0.01. Greater mean deviation (MD and pattern standard deviation (PSD were strongly correlated with higher %FN in the right (p=0.02 and 0.002, resp. and left eyes (p=0.01 and 0.02, resp.. Conclusion. In this prospective, cross-sectional study, worse MD and PSD are strongly correlated with increased FN in both eyes. Increased FN in the left eye associated with older age might be attributable to test fatigue. Worse sleep quality is associated with decreased FL in the right eye.