WorldWideScience

Sample records for reliable measuring technique

  1. Precision of lumbar intervertebral measurements: does a computer-assisted technique improve reliability?

    Science.gov (United States)

    Pearson, Adam M; Spratt, Kevin F; Genuario, James; McGough, William; Kosman, Katherine; Lurie, Jon; Sengupta, Dilip K

    2011-04-01

    Comparison of intra- and interobserver reliability of digitized manual and computer-assisted intervertebral motion measurements and classification of "instability." To determine if computer-assisted measurement of lumbar intervertebral motion on flexion-extension radiographs improves reliability compared with digitized manual measurements. Many studies have questioned the reliability of manual intervertebral measurements, although few have compared the reliability of computer-assisted and manual measurements on lumbar flexion-extension radiographs. Intervertebral rotation, anterior-posterior (AP) translation, and change in anterior and posterior disc height were measured with a digitized manual technique by three physicians and by three other observers using computer-assisted quantitative motion analysis (QMA) software. Each observer measured 30 sets of digital flexion-extension radiographs (L1-S1) twice. Shrout-Fleiss intraclass correlation coefficients for intra- and interobserver reliabilities were computed. The stability of each level was also classified (instability defined as >4 mm AP translation or 10° rotation), and the intra- and interobserver reliabilities of the two methods were compared using adjusted percent agreement (APA). Intraobserver reliability intraclass correlation coefficients were substantially higher for the QMA technique THAN the digitized manual technique across all measurements: rotation 0.997 versus 0.870, AP translation 0.959 versus 0.557, change in anterior disc height 0.962 versus 0.770, and change in posterior disc height 0.951 versus 0.283. The same pattern was observed for interobserver reliability (rotation 0.962 vs. 0.693, AP translation 0.862 vs. 0.151, change in anterior disc height 0.862 vs. 0.373, and change in posterior disc height 0.730 vs. 0.300). The QMA technique was also more reliable for the classification of "instability." Intraobserver APAs ranged from 87 to 97% for QMA versus 60% to 73% for digitized manual

  2. Techniques, processes, and measures for software safety and reliability

    International Nuclear Information System (INIS)

    Sparkman, D.

    1992-01-01

    The purpose of this report is to provide a detailed survey of current recommended practices and measurement techniques for the development of reliable and safe software-based systems. This report is intended to assist the United States Nuclear Reaction Regulation (NRR) in determining the importance and maturity of the available techniques and in assessing the relevance of individual standards for application to instrumentation and control systems in nuclear power generating stations. Lawrence Livermore National Laboratory (LLNL) provides technical support for the Instrumentation and Control System Branch (ICSB) of NRRin advanced instrumentation and control systems, distributed digital systems, software reliability, and the application of verificafion and validafion for the development of software

  3. Reliability analysis of a phaser measurement unit using a generalized fuzzy lambda-tau(GFLT) technique.

    Science.gov (United States)

    Komal

    2018-05-01

    Nowadays power consumption is increasing day-by-day. To fulfill failure free power requirement, planning and implementation of an effective and reliable power management system is essential. Phasor measurement unit(PMU) is one of the key device in wide area measurement and control systems. The reliable performance of PMU assures failure free power supply for any power system. So, the purpose of the present study is to analyse the reliability of a PMU used for controllability and observability of power systems utilizing available uncertain data. In this paper, a generalized fuzzy lambda-tau (GFLT) technique has been proposed for this purpose. In GFLT, system components' uncertain failure and repair rates are fuzzified using fuzzy numbers having different shapes such as triangular, normal, cauchy, sharp gamma and trapezoidal. To select a suitable fuzzy number for quantifying data uncertainty, system experts' opinion have been considered. The GFLT technique applies fault tree, lambda-tau method, fuzzified data using different membership functions, alpha-cut based fuzzy arithmetic operations to compute some important reliability indices. Furthermore, in this study ranking of critical components of the system using RAM-Index and sensitivity analysis have also been performed. The developed technique may be helpful to improve system performance significantly and can be applied to analyse fuzzy reliability of other engineering systems. Copyright © 2018 ISA. Published by Elsevier Ltd. All rights reserved.

  4. Reliable cost effective technique for in situ ground stress measurements in deep gold mines.

    CSIR Research Space (South Africa)

    Stacey, TR

    1995-07-01

    Full Text Available on these requirements, an in situ stress measurement technique which will be practically applicable in the deep gold mines, has been developed conceptually. Referring to the figure on the following page, this method involves: • a borehole-based system, using... level mines have not been developed. 2 This is some of the background to the present SIMRAC research project, the title ofwhich is “Reliable cost effective technique for in-situ ground stress measurements in deep gold mines”. A copy of the research...

  5. Reliability and comparison of acromion assessment techniques on x-ray and magnetic resonance imaging (reliability of acromion assessment techniques)

    International Nuclear Information System (INIS)

    Viskontas, D.G.; MacDermid, J.C.; Drosdowech, D.S.; Garvin, G.J.; Romano, W.M.; Faber, K.J.

    2005-01-01

    To determine the reliability and correlation of plain radiography and magnetic resonance imaging (MRI) in the assessment of acromion morphology. Materials and Methods: Acromion morphology was assessed using the lateral acromion angle (LAA) and the acromion-humeral interval (AHI). Thirty patients who had x-rays and MRI for impingement syndrome were included. Six blinded observers assessed the acromion morphology subjectively and objectively. Results: Neither acromion assessment technique demonstrated a positive correlation (kappa and intraclass coefficient 0.55) when measured objectively by experienced observers. Conclusion: The LAA and the AHI are both reliable acromion assessment techniques on X-ray and MRI when measured objectively and by experienced observers. (author)

  6. A simple method of measuring tibial tubercle to trochlear groove distance on MRI: description of a novel and reliable technique.

    Science.gov (United States)

    Camp, Christopher L; Heidenreich, Mark J; Dahm, Diane L; Bond, Jeffrey R; Collins, Mark S; Krych, Aaron J

    2016-03-01

    Tibial tubercle-trochlear groove (TT-TG) distance is a variable that helps guide surgical decision-making in patients with patellar instability. The purpose of this study was to compare the accuracy and reliability of an MRI TT-TG measuring technique using a simple external alignment method to a previously validated gold standard technique that requires advanced software read by radiologists. TT-TG was calculated by MRI on 59 knees with a clinical diagnosis of patellar instability in a blinded and randomized fashion by two musculoskeletal radiologists using advanced software and by two orthopaedists using the study technique which utilizes measurements taken on a simple electronic imaging platform. Interrater reliability between the two radiologists and the two orthopaedists and intermethods reliability between the two techniques were calculated using interclass correlation coefficients (ICC) and concordance correlation coefficients (CCC). ICC and CCC values greater than 0.75 were considered to represent excellent agreement. The mean TT-TG distance was 14.7 mm (Standard Deviation (SD) 4.87 mm) and 15.4 mm (SD 5.41) as measured by the radiologists and orthopaedists, respectively. Excellent interobserver agreement was noted between the radiologists (ICC 0.941; CCC 0.941), the orthopaedists (ICC 0.978; CCC 0.976), and the two techniques (ICC 0.941; CCC 0.933). The simple TT-TG distance measurement technique analysed in this study resulted in excellent agreement and reliability as compared to the gold standard technique. This method can predictably be performed by orthopaedic surgeons without advanced radiologic software. II.

  7. Reliability of cervical lordosis measurement techniques on long-cassette radiographs.

    Science.gov (United States)

    Janusz, Piotr; Tyrakowski, Marcin; Yu, Hailong; Siemionow, Kris

    2016-11-01

    Lateral radiographs are commonly used to assess cervical sagittal alignment. Three assessment methods have been described and are commonly utilized in clinical practice. These methods are described for perfect lateral cervical radiographs, however in everyday practice radiograph quality varies. The aim of this study was to compare the reliability and reproducibility of 3 cervical lordosis (CL) measurement methods. Forty-four standing lateral radiographs were randomly chosen from a lateral long-cassette radiograph database. Measurements of CL were performed with: Cobb method C2-C7 (CM), C2-C7 posterior tangent method (PTM), sum of posterior tangent method for each segment (SPTM). Three independent orthopaedic surgeons measured CL using the three methods on 44 lateral radiographs. One researcher used the three methods to measured CL three times at 4-week time intervals. Agreement between the methods as well as their intra- and interobserver reliability were tested and quantified by intraclass correlation coefficient (ICC) and median error for a single measurement (SEM). ICC of 0.75 or more reflected an excellent agreement/reliability. The results were compared with repeated ANOVA test, with p  0.05). All three methods appeared to be highly reliable. Although, high agreement between all measurement methods was shown, we do not recommend using Cobb measurement method interchangeably with PTM or SPTM within a single study as this could lead to error, whereas, such a comparison between tangent methods can be considered.

  8. Reliability analysis techniques in power plant design

    International Nuclear Information System (INIS)

    Chang, N.E.

    1981-01-01

    An overview of reliability analysis techniques is presented as applied to power plant design. The key terms, power plant performance, reliability, availability and maintainability are defined. Reliability modeling, methods of analysis and component reliability data are briefly reviewed. Application of reliability analysis techniques from a design engineering approach to improving power plant productivity is discussed. (author)

  9. Reliability and validity of the ultrasound technique to measure the rectus femoris muscle diameter in older CAD-patients

    Directory of Open Access Journals (Sweden)

    Thomaes Tom

    2012-04-01

    Full Text Available Abstract Background The increasing age of coronary artery disease (CAD patients and the occurrence of sarcopenia in the elderly population accompanied by 'fear of moving' and hospitalization in these patients often results in a substantial loss of skeletal muscle mass and muscle strength. Cardiac rehabilitation can improve exercise tolerance and muscle strength in CAD patients but less data describe eventual morphological muscular changes possibly by more difficult access to imaging techniques. Therefore the aim of this study is to assess and quantify the reliability and validity of an easy applicable method, the ultrasound (US technique, to measure the diameter of rectus femoris muscle in comparison to the muscle dimensions measured with CT scans. Methods 45 older CAD patients without cardiac event during the last 9 months were included in this study. 25 patients were tested twice with ultrasound with a two day interval to assess test-retest reliability and 20 patients were tested twice (once with US and once with CT on the same day to assess the validity of the US technique compared to CT as the gold standard. Isometric and isokinetic muscle testing was performed to test potential zero-order correlations between muscle diameter, muscle volume and muscle force. Results An intraclass correlation coefficient (ICC of 0.97 ((95%CL: 0.92 - 0.99 was found for the test-retest reliability of US and the ICC computed between US and CT was 0.92 (95%CL: 0.81 - 0.97. The absolute difference between both techniques was 0.01 ± 0.12 cm (p = 0.66 resulting in a typical percentage error of 4.4%. Significant zero-order correlations were found between local muscle volume and muscle diameter assessed with CT (r = 0.67, p = 0.001 and assessed with US (r = 0.49, p Conclusions Ultrasound imaging can be used as a valid and reliable measurement tool to assess the rectus femoris muscle diameter in older CAD patients.

  10. Reliability of capturing foot parameters using digital scanning and the neutral suspension casting technique

    Science.gov (United States)

    2011-01-01

    Background A clinical study was conducted to determine the intra and inter-rater reliability of digital scanning and the neutral suspension casting technique to measure six foot parameters. The neutral suspension casting technique is a commonly utilised method for obtaining a negative impression of the foot prior to orthotic fabrication. Digital scanning offers an alternative to the traditional plaster of Paris techniques. Methods Twenty one healthy participants volunteered to take part in the study. Six casts and six digital scans were obtained from each participant by two raters of differing clinical experience. The foot parameters chosen for investigation were cast length (mm), forefoot width (mm), rearfoot width (mm), medial arch height (mm), lateral arch height (mm) and forefoot to rearfoot alignment (degrees). Intraclass correlation coefficients (ICC) with 95% confidence intervals (CI) were calculated to determine the intra and inter-rater reliability. Measurement error was assessed through the calculation of the standard error of the measurement (SEM) and smallest real difference (SRD). Results ICC values for all foot parameters using digital scanning ranged between 0.81-0.99 for both intra and inter-rater reliability. For neutral suspension casting technique inter-rater reliability values ranged from 0.57-0.99 and intra-rater reliability values ranging from 0.36-0.99 for rater 1 and 0.49-0.99 for rater 2. Conclusions The findings of this study indicate that digital scanning is a reliable technique, irrespective of clinical experience, with reduced measurement variability in all foot parameters investigated when compared to neutral suspension casting. PMID:21375757

  11. Reliability of a new method for measuring coronal trunk imbalance, the axis-line-angle technique.

    Science.gov (United States)

    Zhang, Rui-Fang; Liu, Kun; Wang, Xue; Liu, Qian; He, Jia-Wei; Wang, Xiang-Yang; Yan, Zhi-Han

    2015-12-01

    Accurate determination of the extent of trunk imbalance in the coronal plane plays a key role in an evaluation of patients with trunk imbalance, such as patients with adolescent idiopathic scoliosis. An established, widely used practice in evaluating trunk imbalance is to drop a plumb line from the C7 vertebra to a key reference axis, the central sacral vertical line (CSVL) in full-spine standing anterioposterior radiographs, and measuring the distance between them, the C7-CSVL. However, measuring the CSVL is subject to intraobserver differences, is error-prone, and is of poor reliability. Therefore, the development of a different way to measure trunk imbalance is needed. This study aimed to describe a new method to measure coronal trunk imbalance, the axis-line-angle technique (ALAT), which measures the angle at the intersection between the C7 plumb line and an axis line drawn from the vertebral centroid of the C7 to the middle of the superior border of the symphysis pubis, and to compare the reliability of the ALAT with that of the C7-CSVL. A prospective study at a university hospital was used. The patient sample consisted of sixty-nine consecutively enrolled men and women patients, aged 10-18 years, who had trunk imbalance defined as C7-CSVL longer than 20 mm on computed full-spine standing anterioposterior radiographs. Data were analyzed to determine the correlation between C7-CSVL and ALAT measurements and to determine intraobserver and interobserver reliabilities. Using a picture archiving and communication system, three radiologists independently evaluated trunk imbalance on the 69 computed radiographs by measuring the C7-CSVL and by measuring the angle determined by the ALAT. Data were analyzed to determine the correlations between the two measures of trunk imbalance, and to determine intraobserver and interobserver reliabilities of each of them. Overall results from the measurements by the C7-CSVL and the ALAT were significantly moderately correlated

  12. Highly reliable TOFD UT Technique

    International Nuclear Information System (INIS)

    Acharya, G.D.; Trivedi, S.A.R.; Pai, K.B.

    2003-01-01

    The high performance of the time of flight diffraction technique (TOFD) with regard to the detection capabilities of weld defects such as crack, slag, lack of fusion has led to a rapidly increasing acceptance of the technique as a pre?service inspection tool. Since the early 1990s TOFD has been applied to several projects, where it replaced the commonly used radiographic testing. The use of TOM lead to major time savings during new build and replacement projects. At the same time the TOFD technique was used as base line inspection, which enables monitoring in the future for critical welds, but also provides documented evidence for life?time. The TOFD technique as the ability to detect and simultaneously size flows of nearly any orientation within the weld and heat affected zone. TOM is recognized as a reliable, proven technique for detection and sizing of defects and proven to be a time saver, resulting in shorter shutdown periods and construction project times. Thus even in cases where inspection price of TOFD per welds is higher, in the end it will result in significantly lower overall costs and improve quality. This paper deals with reliability, economy, acceptance criteria and field experience. It also covers comparative study between radiography technique Vs. TOFD. (Author)

  13. Industrial level measurement techniques - a review

    International Nuclear Information System (INIS)

    Schaudel, D.E.

    1984-01-01

    The outlined methods of industrial level measurement technique are nowadays in current use. In correspondence with the technical evolution the mechanical techniques are mentioned first, followed by a description of the more modern electronic methods. These measurement methods comply especially to the requirements of computer aided process guiding systems, i.e. compatibility of signals, self-checking and reliability. (orig.) [de

  14. A comparison of manual anthropometric measurements with Kinect-based scanned measurements in terms of precision and reliability.

    Science.gov (United States)

    Bragança, Sara; Arezes, Pedro; Carvalho, Miguel; Ashdown, Susan P; Castellucci, Ignacio; Leão, Celina

    2018-01-01

    Collecting anthropometric data for real-life applications demands a high degree of precision and reliability. It is important to test new equipment that will be used for data collectionOBJECTIVE:Compare two anthropometric data gathering techniques - manual methods and a Kinect-based 3D body scanner - to understand which of them gives more precise and reliable results. The data was collected using a measuring tape and a Kinect-based 3D body scanner. It was evaluated in terms of precision by considering the regular and relative Technical Error of Measurement and in terms of reliability by using the Intraclass Correlation Coefficient, Reliability Coefficient, Standard Error of Measurement and Coefficient of Variation. The results obtained showed that both methods presented better results for reliability than for precision. Both methods showed relatively good results for these two variables, however, manual methods had better results for some body measurements. Despite being considered sufficiently precise and reliable for certain applications (e.g. apparel industry), the 3D scanner tested showed, for almost every anthropometric measurement, a different result than the manual technique. Many companies design their products based on data obtained from 3D scanners, hence, understanding the precision and reliability of the equipment used is essential to obtain feasible results.

  15. Reliability of System Identification Techniques to Assess Standing Balance in Healthy Elderly.

    Directory of Open Access Journals (Sweden)

    Jantsje H Pasma

    Full Text Available System identification techniques have the potential to assess the contribution of the underlying systems involved in standing balance by applying well-known disturbances. We investigated the reliability of standing balance parameters obtained with multivariate closed loop system identification techniques.In twelve healthy elderly balance tests were performed twice a day during three days. Body sway was measured during two minutes of standing with eyes closed and the Balance test Room (BalRoom was used to apply four disturbances simultaneously: two sensory disturbances, to the proprioceptive and the visual system, and two mechanical disturbances applied at the leg and trunk segment. Using system identification techniques, sensitivity functions of the sensory disturbances and the neuromuscular controller were estimated. Based on the generalizability theory (G theory, systematic errors and sources of variability were assessed using linear mixed models and reliability was assessed by computing indexes of dependability (ID, standard error of measurement (SEM and minimal detectable change (MDC.A systematic error was found between the first and second trial in the sensitivity functions. No systematic error was found in the neuromuscular controller and body sway. The reliability of 15 of 25 parameters and body sway were moderate to excellent when the results of two trials on three days were averaged. To reach an excellent reliability on one day in 7 out of 25 parameters, it was predicted that at least seven trials must be averaged.This study shows that system identification techniques are a promising method to assess the underlying systems involved in standing balance in elderly. However, most of the parameters do not appear to be reliable unless a large number of trials are collected across multiple days. To reach an excellent reliability in one third of the parameters, a training session for participants is needed and at least seven trials of two

  16. Reliability of a two-wavelength autofluorescence technique by Heidelberg Spectralis to measure macular pigment optical density in Asian subjects.

    Science.gov (United States)

    Obana, Akira; Gellermann, Werner; Gohto, Yuko; Seto, Takahiko; Sasano, Hiroyuki; Tanito, Masaki; Okazaki, Shigetoshi

    2018-03-01

    This study evaluates the accuracy of an objective two-wavelength fundus autofluorescence technique for the purpose of measuring the macular pigment optical density (MPOD) in Asian pigmented eyes. Potential differences between MPOD values obtained via autofluorescence technique and subjective heterochromatic photometry (HFP) were examined. Inter-examiner reproducibility between three examiners and test-retest reliability over five time points were also explored. Subjects were 27 healthy Japanese volunteers aged 24 to 58 (mean ± standard deviation, 40.2 ± 9.0) years. An MPOD module of the Spectralis MultiColor instrument configuration (Spectralis-MP) was used for the autofluorescence technique, and a Macular Metrics Densitometer (MM) was used for HFP. The mean MPOD values at 0.25° and 0.5° eccentricities using the Spectralis-MP were 0.51 ± 0.12 and 0.48 ± 0.13, respectively. In comparison, the MM based values were 0.72 ± 0.23 and 0.61 ± 0.25, respectively. High correlations between the Spectralis-MP and MM instrument were found (Pearson's correlation coefficients of 0.73 and 0.87 at 0.25° and 0.5° eccentricities, respectively), but there was a systematic bias: the MPOD values by MM method were significantly higher than those by Spectralis-MP at 0.25° eccentricity. High inter-examiner reproducibility and test-retest reliability were found for MM measurements at 0.5° eccentricity, but not at 0.25°. The Spectralis-MP showed less inter-examiner and test-retest variability than the MM instrument at 0.25° and 0.5° eccentricities. We conclude that the Spectralis-MP, given its high agreement with the HFP method and due to its higher reproducibility and reliability, is well suited for clinical measurements of MPOD levels in Asian pigmented eyes. Copyright © 2018. Published by Elsevier Ltd.

  17. Inter-rater and intra-rater reliability of a clinical protocol for measuring turnout in collegiate dancers.

    Science.gov (United States)

    Greene, Amanda; Lasner, Andrea; Deu, Rajwinder; Oliphant, Seth; Johnson, Kenneth

    2018-02-02

    Reliable methods of measuring turnout in dancers and comparing active turnout (used in class) with functional (uncompensated) turnout are needed. Authors have suggested measurement techniques but there is no clinically useful, easily reproducible technique with established inter-rater and intra-rater reliability. We adapted a technique based on previous research, which is easily reproducible. We hypothesized excellent inter-rater and intra-rater reliability between experienced physical therapists (PTs) and a briefly trained faculty member from a university's department of dance. Thirty-two participants were recruited from the same dance department. Dancers' active and functional turnout was measured by each rater. We found that our technique for measuring active and functional turnout has excellent inter-rater and intra-rater reliability when performed by two experienced PTs and by one briefly trained university-level dance faculty member. For active turnout, inter-rater reliability was 0.78 among all raters and 0.82 among only the PT raters; intra-rater reliability was 0.82 among all raters and 0.85 among only the PT raters. For functional turnout, inter-rater reliability was 0.86 among all raters and 0.88 among only the PT raters; intra-rater reliability was 0.87 among all raters and 0.88 among only the PT raters. The measurement technique described provides a standardized protocol with excellent inter-rater and intra-rater reliability when performed by experienced PTs or by a briefly trained university-level dance faculty member.

  18. Reliability assessment of restructured power systems using reliability network equivalent and pseudo-sequential simulation techniques

    International Nuclear Information System (INIS)

    Ding, Yi; Wang, Peng; Goel, Lalit; Billinton, Roy; Karki, Rajesh

    2007-01-01

    This paper presents a technique to evaluate reliability of a restructured power system with a bilateral market. The proposed technique is based on the combination of the reliability network equivalent and pseudo-sequential simulation approaches. The reliability network equivalent techniques have been implemented in the Monte Carlo simulation procedure to reduce the computational burden of the analysis. Pseudo-sequential simulation has been used to increase the computational efficiency of the non-sequential simulation method and to model the chronological aspects of market trading and system operation. Multi-state Markov models for generation and transmission systems are proposed and implemented in the simulation. A new load shedding scheme is proposed during generation inadequacy and network congestion to minimize the load curtailment. The IEEE reliability test system (RTS) is used to illustrate the technique. (author)

  19. RELIABILITY OF CERTAIN TESTS FOR EVALUATION OF JUDO TECHNIQUES

    Directory of Open Access Journals (Sweden)

    Slavko Obadov

    2007-05-01

    Full Text Available The sample included 106 judokas. Assessment of the level of mastership of judo techniques was carried out by evaluation of fi ve competent studies. Each subject performed a technique three times and each performance was evaluated by the judges. In order to evaluate measurement of each technique, Cronbach’s coeffi cient of reliability  was calculated. During the procedure the subjects's results were also transformed to factor scores i.e. the results of each performer at the main component of evaluation in the fi ve studies. These factor scores could be used in the subsequent procedure of multivariant statistical analysis.

  20. Reliability of impedance cardiography in measuring central haemodynamics

    DEFF Research Database (Denmark)

    Mehlsen, J; Bonde, J; Stadeager, C

    1991-01-01

    The purpose of the study described here was to investigate the reliability of impedance cardiography (IC) in measuring cardiac output (CO) and central blood volume. Absolute values and changes in these variables obtained by impedance cardiography and by isotope- or thermodilution techniques were...... suitable for repeated measurements in studies on the haemodynamic effects of physiological or pharmacological intervention. Impedance cardiography is sufficiently reliable for comparison of absolute values of CO between different groups of patients. We cannot recommend impedance cardiography...... healthy subjects and in 25 unmedicated patients with ischaemic heart disease. We obtained significant correlations between absolute values (y = 0.68x + 1.48) and changes (y = 1.00x + 0.0003) in CO measured by IC and isotope- or thermodilution. IC significantly overestimated absolute values of CO (P less...

  1. A comparative evaluation of five human reliability assessment techniques

    International Nuclear Information System (INIS)

    Kirwan, B.

    1988-01-01

    A field experiment was undertaken to evaluate the accuracy, usefulness, and resources requirements of five human reliability quantification techniques (Techniques for Human Error Rate Prediction (THERP); Paired Comparisons, Human Error Assessment and Reduction Technique (HEART), Success Liklihood Index Method (SLIM)-Multi Attribute Utility Decomposition (MAUD), and Absolute Probability Judgement). This was achieved by assessing technique predictions against a set of known human error probabilities, and by comparing their predictions on a set of five realistic Probabilisitc Risk Assessment (PRA) human error. On a combined measure of accuracy THERP and Absolute Probability Judgement performed best, whilst HEART showed indications of accuracy and was lower in resources usage than other techniques. HEART and THERP both appear to benefit from using trained assessors in order to obtain the best results. SLIM and Paired Comparisons require further research on achieving a robust calibration relationship between their scale values and absolute probabilities. (author)

  2. OSS reliability measurement and assessment

    CERN Document Server

    Yamada, Shigeru

    2016-01-01

    This book analyses quantitative open source software (OSS) reliability assessment and its applications, focusing on three major topic areas: the Fundamentals of OSS Quality/Reliability Measurement and Assessment; the Practical Applications of OSS Reliability Modelling; and Recent Developments in OSS Reliability Modelling. Offering an ideal reference guide for graduate students and researchers in reliability for open source software (OSS) and modelling, the book introduces several methods of reliability assessment for OSS including component-oriented reliability analysis based on analytic hierarchy process (AHP), analytic network process (ANP), and non-homogeneous Poisson process (NHPP) models, the stochastic differential equation models and hazard rate models. These measurement and management technologies are essential to producing and maintaining quality/reliable systems using OSS.

  3. Prediction of Software Reliability using Bio Inspired Soft Computing Techniques.

    Science.gov (United States)

    Diwaker, Chander; Tomar, Pradeep; Poonia, Ramesh C; Singh, Vijander

    2018-04-10

    A lot of models have been made for predicting software reliability. The reliability models are restricted to using particular types of methodologies and restricted number of parameters. There are a number of techniques and methodologies that may be used for reliability prediction. There is need to focus on parameters consideration while estimating reliability. The reliability of a system may increase or decreases depending on the selection of different parameters used. Thus there is need to identify factors that heavily affecting the reliability of the system. In present days, reusability is mostly used in the various area of research. Reusability is the basis of Component-Based System (CBS). The cost, time and human skill can be saved using Component-Based Software Engineering (CBSE) concepts. CBSE metrics may be used to assess those techniques which are more suitable for estimating system reliability. Soft computing is used for small as well as large-scale problems where it is difficult to find accurate results due to uncertainty or randomness. Several possibilities are available to apply soft computing techniques in medicine related problems. Clinical science of medicine using fuzzy-logic, neural network methodology significantly while basic science of medicine using neural-networks-genetic algorithm most frequently and preferably. There is unavoidable interest shown by medical scientists to use the various soft computing methodologies in genetics, physiology, radiology, cardiology and neurology discipline. CBSE boost users to reuse the past and existing software for making new products to provide quality with a saving of time, memory space, and money. This paper focused on assessment of commonly used soft computing technique like Genetic Algorithm (GA), Neural-Network (NN), Fuzzy Logic, Support Vector Machine (SVM), Ant Colony Optimization (ACO), Particle Swarm Optimization (PSO), and Artificial Bee Colony (ABC). This paper presents working of soft computing

  4. Developing safety performance functions incorporating reliability-based risk measures.

    Science.gov (United States)

    Ibrahim, Shewkar El-Bassiouni; Sayed, Tarek

    2011-11-01

    Current geometric design guides provide deterministic standards where the safety margin of the design output is generally unknown and there is little knowledge of the safety implications of deviating from these standards. Several studies have advocated probabilistic geometric design where reliability analysis can be used to account for the uncertainty in the design parameters and to provide a risk measure of the implication of deviation from design standards. However, there is currently no link between measures of design reliability and the quantification of safety using collision frequency. The analysis presented in this paper attempts to bridge this gap by incorporating a reliability-based quantitative risk measure such as the probability of non-compliance (P(nc)) in safety performance functions (SPFs). Establishing this link will allow admitting reliability-based design into traditional benefit-cost analysis and should lead to a wider application of the reliability technique in road design. The present application is concerned with the design of horizontal curves, where the limit state function is defined in terms of the available (supply) and stopping (demand) sight distances. A comprehensive collision and geometric design database of two-lane rural highways is used to investigate the effect of the probability of non-compliance on safety. The reliability analysis was carried out using the First Order Reliability Method (FORM). Two Negative Binomial (NB) SPFs were developed to compare models with and without the reliability-based risk measures. It was found that models incorporating the P(nc) provided a better fit to the data set than the traditional (without risk) NB SPFs for total, injury and fatality (I+F) and property damage only (PDO) collisions. Copyright © 2011 Elsevier Ltd. All rights reserved.

  5. Pattern of alveolar bone loss and reliability of measurements with the radiographic technique

    International Nuclear Information System (INIS)

    Rise, J.; Albandar, J.M.

    1988-01-01

    The purposes of this paper were to study the pattern of bone loss among different teeth at the individual level and to study the effect of using different aggregated units of analysis on measurement error. Bone loss was assessed in standardized periapical radiographs from 293 subjects (18-68 years), and the mean bone loss score for each tooth type was calculated. These were then correlated by means of factor analysis to study the bone loss pattern. Reliability (measurement error) was studied by the internal consistency and the test-retest methods. The pattern of bone loss showed a unidimensional pattern, indicating that any tooth will work equally well as a dependent variable for epidemiologic descriptive purposes. However, a more thorough analysis also showed a multidimensional pattern in terms of four dimensions, which correspond to four tooth groups: incisors, upper premolars, lower premolars and molars. The four dimensions accounted for 80% of the toal variance. The multidimensional pattern may be important for the modeling of bone loss; thus different models may explain the four dimension (indices) used as dependent variables. The reliability (internal consistency) of the four indices was satisfactory. By the test-retest method, reliability was higher when the more aggregated unit (the individual) was used

  6. Reliability of Two Smartphone Applications for Radiographic Measurements of Hallux Valgus Angles.

    Science.gov (United States)

    Mattos E Dinato, Mauro Cesar; Freitas, Marcio de Faria; Milano, Cristiano; Valloto, Elcio; Ninomiya, André Felipe; Pagnano, Rodrigo Gonçalves

    The objective of the present study was to assess the reliability of 2 smartphone applications compared with the traditional goniometer technique for measurement of radiographic angles in hallux valgus and the time required for analysis with the different methods. The radiographs of 31 patients (52 feet) with a diagnosis of hallux valgus were analyzed. Four observers, 2 with >10 years' experience in foot and ankle surgery and 2 in-training surgeons, measured the hallux valgus angle and intermetatarsal angle using a manual goniometer technique and 2 smartphone applications (Hallux Angles and iPinPoint). The interobserver and intermethod reliability were estimated using intraclass correlation coefficients (ICCs), and the time required for measurement of the angles among the 3 methods was compared using the Friedman test. A very good or good interobserver reliability was found among the 4 observers measuring the hallux valgus angle and intermetatarsal angle using the goniometer (ICC 0.913 and 0.821, respectively) and iPinPoint (ICC 0.866 and 0.638, respectively). Using the Hallux Angles application, a very good interobserver reliability was found for measurements of the hallux valgus angle (ICC 0.962) and intermetatarsal angle (ICC 0.935) only among the more experienced observers. The time required for the measurements was significantly shorter for the measurements using both smartphone applications compared with the goniometer method. One smartphone application (iPinPoint) was reliable for measurements of the hallux valgus angles by either experienced or nonexperienced observers. The use of these tools might save time in the evaluation of radiographic angles in the hallux valgus. Copyright © 2016 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  7. Comparative measurement of collagen bundle orientation by Fourier analysis and semiquantitative evaluation: reliability and agreement in Masson's trichrome, Picrosirius red and confocal microscopy techniques.

    Science.gov (United States)

    Marcos-Garcés, V; Harvat, M; Molina Aguilar, P; Ferrández Izquierdo, A; Ruiz-Saurí, A

    2017-08-01

    Measurement of collagen bundle orientation in histopathological samples is a widely used and useful technique in many research and clinical scenarios. Fourier analysis is the preferred method for performing this measurement, but the most appropriate staining and microscopy technique remains unclear. Some authors advocate the use of Haematoxylin-Eosin (H&E) and confocal microscopy, but there are no studies comparing this technique with other classical collagen stainings. In our study, 46 human skin samples were collected, processed for histological analysis and stained with Masson's trichrome, Picrosirius red and H&E. Five microphotographs of the reticular dermis were taken with a 200× magnification with light microscopy, polarized microscopy and confocal microscopy, respectively. Two independent observers measured collagen bundle orientation with semiautomated Fourier analysis with the Image-Pro Plus 7.0 software and three independent observers performed a semiquantitative evaluation of the same parameter. The average orientation for each case was calculated with the values of the five pictures. We analyzed the interrater reliability, the consistency between Fourier analysis and average semiquantitative evaluation and the consistency between measurements in Masson's trichrome, Picrosirius red and H&E-confocal. Statistical analysis for reliability and agreement was performed with the SPSS 22.0 software and consisted of intraclass correlation coefficient (ICC), Bland-Altman plots and limits of agreement and coefficient of variation. Interrater reliability was almost perfect (ICC > 0.8) with all three histological and microscopy techniques and always superior in Fourier analysis than in average semiquantitative evaluation. Measurements were consistent between Fourier analysis by one observer and average semiquantitative evaluation by three observers, with an almost perfect agreement with Masson's trichrome and Picrosirius red techniques (ICC > 0.8) and a strong

  8. Reliability-guided digital image correlation for image deformation measurement

    International Nuclear Information System (INIS)

    Pan Bing

    2009-01-01

    A universally applicable reliability-guided digital image correlation (DIC) method is proposed for reliable image deformation measurement. The zero-mean normalized cross correlation (ZNCC) coefficient is used to identify the reliability of the point computed. The correlation calculation begins with a seed point and is then guided by the ZNCC coefficient. That means the neighbors of the point with the highest ZNCC coefficient in a queue for computed points will be processed first. Thus the calculation path is always along the most reliable direction, and possible error propagation of the conventional DIC method can be avoided. The proposed novel DIC method is universally applicable to the images with shadows, discontinuous areas, and deformation discontinuity. Two image pairs were used to evaluate the performance of the proposed technique, and the successful results clearly demonstrate its robustness and effectiveness

  9. Reliability analysis techniques for the design engineer

    International Nuclear Information System (INIS)

    Corran, E.R.; Witt, H.H.

    1982-01-01

    This paper describes a fault tree analysis package that eliminates most of the housekeeping tasks involved in proceeding from the initial construction of a fault tree to the final stage of presenting a reliability analysis in a safety report. It is suitable for designers with relatively little training in reliability analysis and computer operation. Users can rapidly investigate the reliability implications of various options at the design stage and evolve a system which meets specified reliability objectives. Later independent review is thus unlikely to reveal major shortcomings necessitating modification and project delays. The package operates interactively, allowing the user to concentrate on the creative task of developing the system fault tree, which may be modified and displayed graphically. For preliminary analysis, system data can be derived automatically from a generic data bank. As the analysis proceeds, improved estimates of critical failure rates and test and maintenance schedules can be inserted. The technique is applied to the reliability analysis of the recently upgraded HIFAR Containment Isolation System. (author)

  10. Reliability analysis for manual radiographic measures of rotatory subluxation or lateral listhesis in adult scoliosis.

    Science.gov (United States)

    Freedman, Brett A; Horton, William C; Rhee, John M; Edwards, Charles C; Kuklo, Timothy R

    2009-03-15

    Retrospective observational study. To define the inter- and intraobserver reliability of 3 measures of rotatory subluxation (RS) in adult scoliosis (AS). RS is a hallmark of AS. To accurately track this measure, one must know its reliability. Reliability testing has not been performed. PA 36" films of 29 AS patients were collected from one surgeon's practice. Three observers on 2 separate occasions measured all levels with >or=3-mm RS (60 levels, 360 measurements) on the convexity of the involved segment using 3 different techniques-midbody (MB), endplate (EP), and centroid (C). These data were then analyzed to determine the intraclass correlation coefficient (ICC) for inter- and intraobserver reliability. The thoracolumbar/lumbar curve (average 58 degrees ) was the major curve for the majority (62%) of patients. RS at L3/4 was most common (35%). The overall inter- and intraobserver reliability was good-excellent for all methods, but the centroid method consistently had the highest ICC. ICC correlated with observer experience. Moderate-severe arthritic change (present in 55%) and poor image quality (52%) decreased ICC, but it still remained good-excellent for each measure. The reproducibility coefficient for each measure was 4 mm for MB and 2.8 mm for C and EP. MB, EP, and C are reliable techniques to measure RS even in elderly arthritic spines, but the methods inherently produce different values for a given level. The centroid method is most reliable and least influenced by experience. The EP method is easy to perform and very reliable. Spine surgeons should pick their preferred method and apply it consistently. Changes >3 mm suggest RS progression. RS may be a useful measure in addition to Cobb angle in AS. Having defined measurement reliability, the role of RS progression in surgical indications and patient outcomes can be evaluated.

  11. Reliability Analysis Techniques for Communication Networks in Nuclear Power Plant

    International Nuclear Information System (INIS)

    Lim, T. J.; Jang, S. C.; Kang, H. G.; Kim, M. C.; Eom, H. S.; Lee, H. J.

    2006-09-01

    The objectives of this project is to investigate and study existing reliability analysis techniques for communication networks in order to develop reliability analysis models for nuclear power plant's safety-critical networks. It is necessary to make a comprehensive survey of current methodologies for communication network reliability. Major outputs of this study are design characteristics of safety-critical communication networks, efficient algorithms for quantifying reliability of communication networks, and preliminary models for assessing reliability of safety-critical communication networks

  12. The reliability of commonly used electrophysiology measures.

    Science.gov (United States)

    Brown, K E; Lohse, K R; Mayer, I M S; Strigaro, G; Desikan, M; Casula, E P; Meunier, S; Popa, T; Lamy, J-C; Odish, O; Leavitt, B R; Durr, A; Roos, R A C; Tabrizi, S J; Rothwell, J C; Boyd, L A; Orth, M

    Electrophysiological measures can help understand brain function both in healthy individuals and in the context of a disease. Given the amount of information that can be extracted from these measures and their frequent use, it is essential to know more about their inherent reliability. To understand the reliability of electrophysiology measures in healthy individuals. We hypothesized that measures of threshold and latency would be the most reliable and least susceptible to methodological differences between study sites. Somatosensory evoked potentials from 112 control participants; long-latency reflexes, transcranial magnetic stimulation with resting and active motor thresholds, motor evoked potential latencies, input/output curves, and short-latency sensory afferent inhibition and facilitation from 84 controls were collected at 3 visits over 24 months at 4 Track-On HD study sites. Reliability was assessed using intra-class correlation coefficients for absolute agreement, and the effects of reliability on statistical power are demonstrated for different sample sizes and study designs. Measures quantifying latencies, thresholds, and evoked responses at high stimulator intensities had the highest reliability, and required the smallest sample sizes to adequately power a study. Very few between-site differences were detected. Reliability and susceptibility to between-site differences should be evaluated for electrophysiological measures before including them in study designs. Levels of reliability vary substantially across electrophysiological measures, though there are few between-site differences. To address this, reliability should be used in conjunction with theoretical calculations to inform sample size and ensure studies are adequately powered to detect true change in measures of interest. Copyright © 2017 Elsevier Inc. All rights reserved.

  13. Improved radiograph measurement inter-observer reliability by use of statistical shape models

    Energy Technology Data Exchange (ETDEWEB)

    Pegg, E.C., E-mail: elise.pegg@ndorms.ox.ac.uk [University of Oxford, Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, Nuffield Orthopaedic Centre, Windmill Road, Oxford OX3 7LD (United Kingdom); Mellon, S.J., E-mail: stephen.mellon@ndorms.ox.ac.uk [University of Oxford, Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, Nuffield Orthopaedic Centre, Windmill Road, Oxford OX3 7LD (United Kingdom); Salmon, G. [University of Oxford, Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, Nuffield Orthopaedic Centre, Windmill Road, Oxford OX3 7LD (United Kingdom); Alvand, A., E-mail: abtin.alvand@ndorms.ox.ac.uk [University of Oxford, Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, Nuffield Orthopaedic Centre, Windmill Road, Oxford OX3 7LD (United Kingdom); Pandit, H., E-mail: hemant.pandit@ndorms.ox.ac.uk [University of Oxford, Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, Nuffield Orthopaedic Centre, Windmill Road, Oxford OX3 7LD (United Kingdom); Murray, D.W., E-mail: david.murray@ndorms.ox.ac.uk [University of Oxford, Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, Nuffield Orthopaedic Centre, Windmill Road, Oxford OX3 7LD (United Kingdom); Gill, H.S., E-mail: richie.gill@ndorms.ox.ac.uk [University of Oxford, Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, Nuffield Orthopaedic Centre, Windmill Road, Oxford OX3 7LD (United Kingdom)

    2012-10-15

    Pre- and post-operative radiographs of patients undergoing joint arthroplasty are often examined for a variety of purposes including preoperative planning and patient assessment. This work examines the feasibility of using active shape models (ASM) to semi-automate measurements from post-operative radiographs for the specific case of the Oxford™ Unicompartmental Knee. Measurements of the proximal tibia and the position of the tibial tray were made using the ASM model and manually. Data were obtained by four observers and one observer took four sets of measurements to allow assessment of the inter- and intra-observer reliability, respectively. The parameters measured were the tibial tray angle, the tray overhang, the tray size, the sagittal cut position, the resection level and the tibial width. Results demonstrated improved reliability (average of 27% and 11.2% increase for intra- and inter-reliability, respectively) and equivalent accuracy (p > 0.05 for compared data values) for all of the measurements using the ASM model, with the exception of the tray overhang (p = 0.0001). Less time (15 s) was required to take measurements using the ASM model compared with manual measurements, which was significant. These encouraging results indicate that semi-automated measurement techniques could improve the reliability of radiographic measurements.

  14. Improved radiograph measurement inter-observer reliability by use of statistical shape models

    International Nuclear Information System (INIS)

    Pegg, E.C.; Mellon, S.J.; Salmon, G.; Alvand, A.; Pandit, H.; Murray, D.W.; Gill, H.S.

    2012-01-01

    Pre- and post-operative radiographs of patients undergoing joint arthroplasty are often examined for a variety of purposes including preoperative planning and patient assessment. This work examines the feasibility of using active shape models (ASM) to semi-automate measurements from post-operative radiographs for the specific case of the Oxford™ Unicompartmental Knee. Measurements of the proximal tibia and the position of the tibial tray were made using the ASM model and manually. Data were obtained by four observers and one observer took four sets of measurements to allow assessment of the inter- and intra-observer reliability, respectively. The parameters measured were the tibial tray angle, the tray overhang, the tray size, the sagittal cut position, the resection level and the tibial width. Results demonstrated improved reliability (average of 27% and 11.2% increase for intra- and inter-reliability, respectively) and equivalent accuracy (p > 0.05 for compared data values) for all of the measurements using the ASM model, with the exception of the tray overhang (p = 0.0001). Less time (15 s) was required to take measurements using the ASM model compared with manual measurements, which was significant. These encouraging results indicate that semi-automated measurement techniques could improve the reliability of radiographic measurements

  15. A new measurement of workload in Web application reliability assessment

    Directory of Open Access Journals (Sweden)

    CUI Xia

    2015-02-01

    Full Text Available Web application has been popular in various fields of social life.It becomes more and more important to study the reliability of Web application.In this paper the definition of Web application failure is firstly brought out,and then the definition of Web application reliability.By analyzing data in the IIS server logs and selecting corresponding usage and information delivery failure data,the paper study the feasibility of Web application reliability assessment from the perspective of Web software system based on IIS server logs.Because the usage for a Web site often has certain regularity,a new measurement of workload in Web application reliability assessment is raised.In this method,the unit is removed by weighted average technique;and the weights are assessed by setting objective function and optimization.Finally an experiment was raised for validation.The experiment result shows the assessment of Web application reliability base on the new workload is better.

  16. High-voltage test and measuring techniques

    CERN Document Server

    Hauschild, Wolfgang

    2014-01-01

    It is the intent of this book to combine high-voltage (HV) engineering with HV testing technique and HV measuring technique. Based on long-term experience gained by the authors as lecturer and researcher as well as member in international organizations, such as IEC and CIGRE, the book will reflect the state of the art as well as the future trends in testing and diagnostics of HV equipment to ensure a reliable generation, transmission and distribution of electrical energy. The book is intended not only for experts but also for students in electrical engineering and high-voltage engineering.

  17. Reliability of rehabilitative ultrasonographic imaging for muscle thickness measurement of the rhomboid major.

    Science.gov (United States)

    Jeong, Ju Ri; Ko, Young Jun; Ha, Hyun Geun; Lee, Wan Hee

    2016-03-01

    This study was to establish inter-rater and intrarater reliability of the rehabilitative ultrasonographic imaging (RUSI) technique for muscle thickness measurement of the rhomboid major at rest and with the shoulder abducted to 90°. Twenty-four young adults (eight men, 16 women; right-handed; mean age [±SD], 24·4 years [±2·6]) with no history of neck, shoulder, or arm pain were recruited. Rhomboid major muscle images were obtained in the resting position and with shoulder in 90° abduction using an ultrasonography system with a 7·5-MHz linear transducer. In these two positions, the examiners found the site at which the transducer could be placed. Two examiners obtained the images of all participants in three test sessions at random. Intraclass correlation coefficients (ICC) were used to estimate reliability. All ICCs (95% CI) were >0·75, ranging from 0·93 to 0·98, which indicates good reliability. The ICCs for inter-rater reliability ranged from 0·75 to 0·94. For the absolute value of the difference in the intra-examiner reliability between the right and left ratios, the ICCs ranged from 0·58 to 0·91. In this study, the intra- and interexaminer reliability of muscle thickness measurements of the rhomboid major were good. Therefore, we suggest that muscle thickness measurements of the rhomboid major obtained with the RUSI technique would be useful for clinical rehabilitative assessment. © 2014 Scandinavian Society of Clinical Physiology and Nuclear Medicine. Published by John Wiley & Sons Ltd.

  18. Probabilistic risk assessment course documentation. Volume 3. System reliability and analysis techniques, Session A - reliability

    International Nuclear Information System (INIS)

    Lofgren, E.V.

    1985-08-01

    This course in System Reliability and Analysis Techniques focuses on the quantitative estimation of reliability at the systems level. Various methods are reviewed, but the structure provided by the fault tree method is used as the basis for system reliability estimates. The principles of fault tree analysis are briefly reviewed. Contributors to system unreliability and unavailability are reviewed, models are given for quantitative evaluation, and the requirements for both generic and plant-specific data are discussed. Also covered are issues of quantifying component faults that relate to the systems context in which the components are embedded. All reliability terms are carefully defined. 44 figs., 22 tabs

  19. New Technique of Direct Intra-abdominal Pressure Measurement

    Directory of Open Access Journals (Sweden)

    Elena Risin

    2006-10-01

    Conclusion: Direct measurement of intra-abdominal pressure using 14-Fr PVC round drain is a newly described technique that is simple, fast and credible. Future investigation will be needed to confirm the reliability of this method during postoperative follow-up of intra-abdominal pressures in selected patients.

  20. Reliable intraocular pressure measurement using automated radio-wave telemetry.

    Science.gov (United States)

    Paschalis, Eleftherios I; Cade, Fabiano; Melki, Samir; Pasquale, Louis R; Dohlman, Claes H; Ciolino, Joseph B

    2014-01-01

    To present an autonomous intraocular pressure (IOP) measurement technique using a wireless implantable transducer (WIT) and a motion sensor. The WIT optical aid was implanted within the ciliary sulcus of a normotensive rabbit eye after extracapsular clear lens extraction. An autonomous wireless data system (AWDS) comprising of a WIT and an external antenna aided by a motion sensor provided continuous IOP readings. The sensitivity of the technique was determined by the ability to detect IOP changes resulting from the administration of latanoprost 0.005% or dorzolamide 2%, while the reliability was determined by the agreement between baseline and vehicle (saline) IOP. On average, 12 diurnal and 205 nocturnal IOP measurements were performed with latanoprost, and 26 diurnal and 205 nocturnal measurements with dorzolamide. No difference was found between mean baseline IOP (13.08±2.2 mmHg) and mean vehicle IOP (13.27±2.1 mmHg) (P=0.45), suggesting good measurement reliability. Both antiglaucoma medications caused significant IOP reduction compared to baseline; latanoprost reduced mean IOP by 10% (1.3±3.54 mmHg; P<0.001), and dorzolamide by 5% (0.62±2.22 mmHg; P<0.001). Use of latanoprost resulted in an overall twofold higher IOP reduction compared to dorzolamide (P<0.001). Repeatability was ±1.8 mmHg, assessed by the variability of consecutive IOP measurements performed in a short period of time (≤1 minute), during which the IOP is not expected to change. IOP measurements in conscious rabbits obtained without the need for human interactions using the AWDS are feasible and provide reproducible results.

  1. Reliable intraocular pressure measurement using automated radio-wave telemetry

    Science.gov (United States)

    Paschalis, Eleftherios I; Cade, Fabiano; Melki, Samir; Pasquale, Louis R; Dohlman, Claes H; Ciolino, Joseph B

    2014-01-01

    Purpose To present an autonomous intraocular pressure (IOP) measurement technique using a wireless implantable transducer (WIT) and a motion sensor. Methods The WIT optical aid was implanted within the ciliary sulcus of a normotensive rabbit eye after extracapsular clear lens extraction. An autonomous wireless data system (AWDS) comprising of a WIT and an external antenna aided by a motion sensor provided continuous IOP readings. The sensitivity of the technique was determined by the ability to detect IOP changes resulting from the administration of latanoprost 0.005% or dorzolamide 2%, while the reliability was determined by the agreement between baseline and vehicle (saline) IOP. Results On average, 12 diurnal and 205 nocturnal IOP measurements were performed with latanoprost, and 26 diurnal and 205 nocturnal measurements with dorzolamide. No difference was found between mean baseline IOP (13.08±2.2 mmHg) and mean vehicle IOP (13.27±2.1 mmHg) (P=0.45), suggesting good measurement reliability. Both antiglaucoma medications caused significant IOP reduction compared to baseline; latanoprost reduced mean IOP by 10% (1.3±3.54 mmHg; P<0.001), and dorzolamide by 5% (0.62±2.22 mmHg; P<0.001). Use of latanoprost resulted in an overall twofold higher IOP reduction compared to dorzolamide (P<0.001). Repeatability was ±1.8 mmHg, assessed by the variability of consecutive IOP measurements performed in a short period of time (≤1 minute), during which the IOP is not expected to change. Conclusion IOP measurements in conscious rabbits obtained without the need for human interactions using the AWDS are feasible and provide reproducible results. PMID:24531415

  2. Reliability Assessment of Wind Farm Electrical System Based on a Probability Transfer Technique

    Directory of Open Access Journals (Sweden)

    Hejun Yang

    2018-03-01

    Full Text Available The electrical system of a wind farm has a significant influence on the wind farm reliability and electrical energy yield. The disconnect switch installed in an electrical system cannot only improve the operating flexibility, but also enhance the reliability for a wind farm. Therefore, this paper develops a probabilistic transfer technique for integrating the electrical topology structure, the isolation operation of disconnect switch, and stochastic failure of electrical equipment into the reliability assessment of wind farm electrical system. Firstly, as the traditional two-state reliability model of electrical equipment cannot consider the isolation operation, so the paper develops a three-state reliability model to replace the two-state model for incorporating the isolation operation. In addition, a proportion apportion technique is presented to evaluate the state probability. Secondly, this paper develops a probabilistic transfer technique based on the thoughts that through transfer the unreliability of electrical system to the energy transmission interruption of wind turbine generators (WTGs. Finally, some novel indices for describing the reliability of wind farm electrical system are designed, and the variance coefficient of the designed indices is used as a convergence criterion to determine the termination of the assessment process. The proposed technique is applied to the reliability assessment of a wind farm with the different topologies. The simulation results show that the proposed techniques are effective in practical applications.

  3. Reliability of single kidney glomerular filtration rate measured by a 99mTc-DTPA gamma camera technique

    International Nuclear Information System (INIS)

    Rehling, M.; Moller, M.L.; Jensen, J.J.; Thamdrup, B.; Lund, J.O.; Trap-Jensen, J.

    1986-01-01

    The reliability of a previously published method for determination of single kidney glomerular filtration rate (SKGFR) by means of technetium-99m-diethylenetriaminepenta-acetate (99mTc-DTPA) gamma camera renography was evaluated. The day-to-day variation in the calculated SKGFR values was earlier found to be 8.8%. The technique was compared to the simultaneously measured renal clearance of inulin in 19 unilaterally nephrectomized patients with GFR varying from 11 to 76 ml/min. The regression line (y = 1.04 X -2.5) did not differ significantly from the line of identity. The standard error of estimate was 4.3 ml/min. In 17 patients the inter- and intraobserver variation of the calculated SKGFR values was 1.2 ml/min and 1.3 ml/min, respectively. In 21 of 25 healthy subjects studied (age range 27-29 years), total GFR calculated from the renograms was within an established age-dependent normal range of GFR

  4. Quantification of intervertebral displacement with a novel MRI-based modeling technique: Assessing measurement bias and reliability with a porcine spine model.

    Science.gov (United States)

    Mahato, Niladri K; Montuelle, Stephane; Goubeaux, Craig; Cotton, John; Williams, Susan; Thomas, James; Clark, Brian C

    2017-05-01

    The purpose of this study was to develop a novel magnetic resonance imaging (MRI)-based modeling technique for measuring intervertebral displacements. Here, we present the measurement bias and reliability of the developmental work using a porcine spine model. Porcine lumbar vertebral segments were fitted in a custom-built apparatus placed within an externally calibrated imaging volume of an open-MRI scanner. The apparatus allowed movement of the vertebrae through pre-assigned magnitudes of sagittal and coronal translation and rotation. The induced displacements were imaged with static (T 1 ) and fast dynamic (2D HYCE S) pulse sequences. These images were imported into animation software, in which these images formed a background 'scene'. Three-dimensional models of vertebrae were created using static axial scans from the specimen and then transferred into the animation environment. In the animation environment, the user manually moved the models (rotoscoping) to perform model-to-'scene' matching to fit the models to their image silhouettes and assigned anatomical joint axes to the motion-segments. The animation protocol quantified the experimental translation and rotation displacements between the vertebral models. Accuracy of the technique was calculated as 'bias' using a linear mixed effects model, average percentage error and root mean square errors. Between-session reliability was examined by computing intra-class correlation coefficients (ICC) and the coefficient of variations (CV). For translation trials, a constant bias (β 0 ) of 0.35 (±0.11) mm was detected for the 2D HYCE S sequence (p=0.01). The model did not demonstrate significant additional bias with each mm increase in experimental translation (β 1 Displacement=0.01mm; p=0.69). Using the T 1 sequence for the same assessments did not significantly change the bias (p>0.05). ICC values for the T 1 and 2D HYCE S pulse sequences were 0.98 and 0.97, respectively. For rotation trials, a constant bias (

  5. A survey on reliability and safety analysis techniques of robot systems in nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    Eom, H S; Kim, J H; Lee, J C; Choi, Y R; Moon, S S

    2000-12-01

    The reliability and safety analysis techniques was surveyed for the purpose of overall quality improvement of reactor inspection system which is under development in our current project. The contents of this report are : 1. Reliability and safety analysis techniques suvey - Reviewed reliability and safety analysis techniques are generally accepted techniques in many industries including nuclear industry. And we selected a few techniques which are suitable for our robot system. They are falut tree analysis, failure mode and effect analysis, reliability block diagram, markov model, combinational method, and simulation method. 2. Survey on the characteristics of robot systems which are distinguished from other systems and which are important to the analysis. 3. Survey on the nuclear environmental factors which affect the reliability and safety analysis of robot system 4. Collection of the case studies of robot reliability and safety analysis which are performed in foreign countries. The analysis results of this survey will be applied to the improvement of reliability and safety of our robot system and also will be used for the formal qualification and certification of our reactor inspection system.

  6. A survey on reliability and safety analysis techniques of robot systems in nuclear power plants

    International Nuclear Information System (INIS)

    Eom, H.S.; Kim, J.H.; Lee, J.C.; Choi, Y.R.; Moon, S.S.

    2000-12-01

    The reliability and safety analysis techniques was surveyed for the purpose of overall quality improvement of reactor inspection system which is under development in our current project. The contents of this report are : 1. Reliability and safety analysis techniques suvey - Reviewed reliability and safety analysis techniques are generally accepted techniques in many industries including nuclear industry. And we selected a few techniques which are suitable for our robot system. They are falut tree analysis, failure mode and effect analysis, reliability block diagram, markov model, combinational method, and simulation method. 2. Survey on the characteristics of robot systems which are distinguished from other systems and which are important to the analysis. 3. Survey on the nuclear environmental factors which affect the reliability and safety analysis of robot system 4. Collection of the case studies of robot reliability and safety analysis which are performed in foreign countries. The analysis results of this survey will be applied to the improvement of reliability and safety of our robot system and also will be used for the formal qualification and certification of our reactor inspection system

  7. Improvement of AC motor reliability from technique standardization

    International Nuclear Information System (INIS)

    Muniz, P.R.; Faria, M.D.R.; Mendes, M.P.; Silva, J.N.; Dos Santos, J.D.

    2005-01-01

    The purpose of this paper is to explain the increase of reliability of motors serviced in the Electrical Maintenance Shop of Companhia Siderurgica de Tubarao by standardization of the technique based on Brazilian and International Standards, manufacturer's recommendations and the experience of the maintenance staff. (author)

  8. Structural reliability analysis based on the cokriging technique

    International Nuclear Information System (INIS)

    Zhao Wei; Wang Wei; Dai Hongzhe; Xue Guofeng

    2010-01-01

    Approximation methods are widely used in structural reliability analysis because they are simple to create and provide explicit functional relationships between the responses and variables in stead of the implicit limit state function. Recently, the kriging method which is a semi-parameter interpolation technique that can be used for deterministic optimization and structural reliability has gained popularity. However, to fully exploit the kriging method, especially in high-dimensional problems, a large number of sample points should be generated to fill the design space and this can be very expensive and even impractical in practical engineering analysis. Therefore, in this paper, a new method-the cokriging method, which is an extension of kriging, is proposed to calculate the structural reliability. cokriging approximation incorporates secondary information such as the values of the gradients of the function being approximated. This paper explores the use of the cokriging method for structural reliability problems by comparing it with the Kriging method based on some numerical examples. The results indicate that the cokriging procedure described in this work can generate approximation models to improve on the accuracy and efficiency for structural reliability problems and is a viable alternative to the kriging.

  9. Reliability and normative values of the foot line test: a technique to assess foot posture

    DEFF Research Database (Denmark)

    Brushøj, C; Larsen, Klaus; Nielsen, MB

    2007-01-01

    STUDY DESIGN: Test-retest reliability. OBJECTIVE: To examine the reliability and report normative values of a novel test, the foot line test (FLT), to describe foot morphology. BACKGROUND: Numerous foot examinations are performed each day, but most existing examination techniques have considerable...... limitations regarding reliability and validity. METHODS: One hundred thirty subjects with mean foot size 44 (41-50 European size) participated. Two examiners, blinded to each other's measurements, measured the right foot of the subjects twice and the left foot once. The position of the most medial aspect...... of the navicular in the mediolateral direction was projected vertically onto a piece of paper placed under the subject's foot, and compared to the position of the forefoot and hindfoot to obtain the FLT value. RESULTS: FLT values ranged from -8 to 14 mm, with a mean (+/-SD) of 3.7 +/- 3.4 mm. The intratester...

  10. WAYS TO INCREASE ACCURACY AND RELIABILITY OF INDIVIDUAL DOSES ASSESSMENTS IN PERSONNEL WITHIN THERMOLUMINESCENCE TECHNIQUE

    Directory of Open Access Journals (Sweden)

    G. N. Kaydanovskiy

    2012-01-01

    Full Text Available The paper analyses the main sources of measurement errors of individual doses in personnel performed within the thermoluminescence technique and gives recommendations to minimize these errors. The reasons that reduce reliability of effective dose assessments derived from measured values of personal dose equivalent are imperfections of guidance documents. Changes to the Guidelines «Organization and implementation of individual dosimetric control. Staff of health institutions» are justified.

  11. Reliability and validity of non-radiographic methods of thoracic kyphosis measurement: a systematic review.

    Science.gov (United States)

    Barrett, Eva; McCreesh, Karen; Lewis, Jeremy

    2014-02-01

    A wide array of instruments are available for non-invasive thoracic kyphosis measurement. Guidelines for selecting outcome measures for use in clinical and research practice recommend that properties such as validity and reliability are considered. This systematic review reports on the reliability and validity of non-invasive methods for measuring thoracic kyphosis. A systematic search of 11 electronic databases located studies assessing reliability and/or validity of non-invasive thoracic kyphosis measurement techniques. Two independent reviewers used a critical appraisal tool to assess the quality of retrieved studies. Data was extracted by the primary reviewer. The results were synthesized qualitatively using a level of evidence approach. 27 studies satisfied the eligibility criteria and were included in the review. The reliability, validity and both reliability and validity were investigated by sixteen, two and nine studies respectively. 17/27 studies were deemed to be of high quality. In total, 15 methods of thoracic kyphosis were evaluated in retrieved studies. All investigated methods showed high (ICC ≥ .7) to very high (ICC ≥ .9) levels of reliability. The validity of the methods ranged from low to very high. The strongest levels of evidence for reliability exists in support of the Debrunner kyphometer, Spinal Mouse and Flexicurve index, and for validity supports the arcometer and Flexicurve index. Further reliability and validity studies are required to strengthen the level of evidence for the remaining methods of measurement. This should be addressed by future research. Copyright © 2013 Elsevier Ltd. All rights reserved.

  12. Measurement of the buccolingual inclination of teeth: manual technique vs 3-dimensional software.

    Science.gov (United States)

    Nouri, Mahtab; Abdi, Amir Hossein; Farzan, Arash; Mokhtarpour, Faraneh; Baghban, AliReza Akbarzadeh

    2014-10-01

    In this study, we aimed to measure the inclination of teeth on dental casts by a manual technique with the tooth inclination protractor (TIP; MBI, Newport, United Kingdom) and a newly designed 3-dimensional (3D) software program. The correlation of the 2 techniques was evaluated, and the reliability of each technique was assessed separately. This study was conducted on 36 dental casts of normal, well-aligned Class I occlusions; we assessed 432 teeth. All casts had a normal Class I occlusion. After determining the facial axis of the clinical crown and the facial axis points on the dental casts, we measured the inclinations of the incisors and posterior teeth up to the first molars in each dental arch relative to Andrews' occlusal plane and the posterior occlusal plane using the TIP. Moreover, the casts were scanned by a structured-light 3D scanner. The inclination of teeth relative to the occlusal plane was determined using the new software. To assess the reliability, measurements of all teeth from 15 casts were repeated twice by the 2 methods. Intraclass correlation coefficient and Dahlberg's formula were used for calculation of correlation and reliability. Overall, the 2 techniques were not significantly different in the measurements of the inclinations of the teeth in both jaws. The ranges of Dahlberg's formula were 3.1° to 5.8° for the maxilla and 3.3° to 5.9° for the mandible. The overall correlation of the 2 techniques according to the intraclass correlation coefficient was 0.91. For calculation of reliability, the intraclass correlation coefficients for the TIP and the 3D method were 0.73 and 0.82, respectively. The TIP and the 3D software showed a high correlation for measurement of the inclinations of maxillary and mandibular teeth relative to the occlusal plane. Also, the reproducibility of the measurements in each method was high. Copyright © 2014 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.

  13. MEASUREMENT: ACCOUNTING FOR RELIABILITY IN PERFORMANCE ESTIMATES.

    Science.gov (United States)

    Waterman, Brian; Sutter, Robert; Burroughs, Thomas; Dunagan, W Claiborne

    2014-01-01

    When evaluating physician performance measures, physician leaders are faced with the quandary of determining whether departures from expected physician performance measurements represent a true signal or random error. This uncertainty impedes the physician leader's ability and confidence to take appropriate performance improvement actions based on physician performance measurements. Incorporating reliability adjustment into physician performance measurement is a valuable way of reducing the impact of random error in the measurements, such as those caused by small sample sizes. Consequently, the physician executive has more confidence that the results represent true performance and is positioned to make better physician performance improvement decisions. Applying reliability adjustment to physician-level performance data is relatively new. As others have noted previously, it's important to keep in mind that reliability adjustment adds significant complexity to the production, interpretation and utilization of results. Furthermore, the methods explored in this case study only scratch the surface of the range of available Bayesian methods that can be used for reliability adjustment; further study is needed to test and compare these methods in practice and to examine important extensions for handling specialty-specific concerns (e.g., average case volumes, which have been shown to be important in cardiac surgery outcomes). Moreover, it's important to note that the provider group average as a basis for shrinkage is one of several possible choices that could be employed in practice and deserves further exploration in future research. With these caveats, our results demonstrate that incorporating reliability adjustment into physician performance measurements is feasible and can notably reduce the incidence of "real" signals relative to what one would expect to see using more traditional approaches. A physician leader who is interested in catalyzing performance improvement

  14. A Novel Analytic Technique for the Service Station Reliability in a Discrete-Time Repairable Queue

    Directory of Open Access Journals (Sweden)

    Renbin Liu

    2013-01-01

    Full Text Available This paper presents a decomposition technique for the service station reliability in a discrete-time repairable GeomX/G/1 queueing system, in which the server takes exhaustive service and multiple adaptive delayed vacation discipline. Using such a novel analytic technique, some important reliability indices and reliability relation equations of the service station are derived. Furthermore, the structures of the service station indices are also found. Finally, special cases and numerical examples validate the derived results and show that our analytic technique is applicable to reliability analysis of some complex discrete-time repairable bulk arrival queueing systems.

  15. Reliable intraocular pressure measurement using automated radio-wave telemetry

    Directory of Open Access Journals (Sweden)

    Paschalis EI

    2014-01-01

    Full Text Available Eleftherios I Paschalis,* Fabiano Cade,* Samir Melki, Louis R Pasquale, Claes H Dohlman, Joseph B CiolinoMassachusetts Eye and Ear Infirmary, Harvard Medical School, Boston, MA, USA*These authors contributed equally to this workPurpose: To present an autonomous intraocular pressure (IOP measurement technique using a wireless implantable transducer (WIT and a motion sensor.Methods: The WIT optical aid was implanted within the ciliary sulcus of a normotensive rabbit eye after extracapsular clear lens extraction. An autonomous wireless data system (AWDS comprising of a WIT and an external antenna aided by a motion sensor provided continuous IOP readings. The sensitivity of the technique was determined by the ability to detect IOP changes resulting from the administration of latanoprost 0.005% or dorzolamide 2%, while the reliability was determined by the agreement between baseline and vehicle (saline IOP.Results: On average, 12 diurnal and 205 nocturnal IOP measurements were performed with latanoprost, and 26 diurnal and 205 nocturnal measurements with dorzolamide. No difference was found between mean baseline IOP (13.08±2.2 mmHg and mean vehicle IOP (13.27±2.1 mmHg (P=0.45, suggesting good measurement reliability. Both antiglaucoma medications caused significant IOP reduction compared to baseline; latanoprost reduced mean IOP by 10% (1.3±3.54 mmHg; P<0.001, and dorzolamide by 5% (0.62±2.22 mmHg; P<0.001. Use of latanoprost resulted in an overall twofold higher IOP reduction compared to dorzolamide (P<0.001. Repeatability was ±1.8 mmHg, assessed by the variability of consecutive IOP measurements performed in a short period of time (≤1 minute, during which the IOP is not expected to change.Conclusion: IOP measurements in conscious rabbits obtained without the need for human interactions using the AWDS are feasible and provide reproducible results.Keywords: IOP, pressure transducer, wireless, MEMS, implant, intraocular

  16. Reliability of Measuring Lumbar Lordosis, Flexion and Extension Using Dual Inclinometer in Healthy Subjects and Patients with Non-Specific Chronic Low Back Pain

    Directory of Open Access Journals (Sweden)

    Samira Garmabi

    2012-07-01

    Full Text Available Objective: Accurate assessment of lumbar range of motion is of great value for both evaluating lumbar functions and monitoring treatment progress. Recent research indicates that there is no general consensus on the most valid and reliable method of measuring spinal range of motion. The purpose of this study was to determine the intra-rater reliability of lumbar flexion and extension measurements (within-day and between-days using the dual inclinometer technique.   Materials & Methods: Lumbar flexion and extension of 22 women (14 healthy and 8 with low back pain, were measured by the same examiner on three occasions. The first two measurements were taken with half an hour apart on the first occasion to assess the within-day reliability and the third measurement was taken one week later to assess the between-days reliability.  Results: Within-day lumbar lordosis, flexion and extension measurements using dual inclinometer technique were shown to be very reliable with high Intraclass Correlation Coefficients (ICC values (ICC were 98%, 77% and 69% for lordosis, flexion and extension measurements, respectively in healthy subjects and 94%, 95% and 69% for lordosis, flexion and extension measurements, respectively in patients group. Between-Days measurements also demonstrated high reliability with the high values of ICC (ICC were 96%, 70% and 67% for lordosis, flexion and extension measurements, in healthy subjects and 91%, 71% and 66% for lordosis, flexion and extension measurements, respectively in patients group. Conclusion: The results indicated that, the dual inclinometer technique appears to be a highly reliable method for measuring lumbar lordosis, flexion and extension and can be used as a reliable tool in the assessment of lumbar range of motion and monitoring therapeutic interventions.

  17. Multivariate performance reliability prediction in real-time

    International Nuclear Information System (INIS)

    Lu, S.; Lu, H.; Kolarik, W.J.

    2001-01-01

    This paper presents a technique for predicting system performance reliability in real-time considering multiple failure modes. The technique includes on-line multivariate monitoring and forecasting of selected performance measures and conditional performance reliability estimates. The performance measures across time are treated as a multivariate time series. A state-space approach is used to model the multivariate time series. Recursive forecasting is performed by adopting Kalman filtering. The predicted mean vectors and covariance matrix of performance measures are used for the assessment of system survival/reliability with respect to the conditional performance reliability. The technique and modeling protocol discussed in this paper provide a means to forecast and evaluate the performance of an individual system in a dynamic environment in real-time. The paper also presents an example to demonstrate the technique

  18. Application of interferometry and Faraday rotation techniques for density measurements on ITER

    International Nuclear Information System (INIS)

    Snider, R.T.; Carlstrom, T.N.; Ma, C.H.; Peebles, W.A.

    1995-01-01

    There is a need for real time, reliable density measurement for density control, compatible with the restricted access and radiation environment on ITER. Line average density measurements using microwave or laser interferometry techniques have proven to be robust and reliable for density control on contemporary tokamaks. In ITER, the large path length, high density and density gradients, limit the wavelength of a probing beam to shorter then about 50 microm due to refraction effects. In this paper the authors consider the design of short wavelength vibration compensated interferometers and Faraday rotation techniques for density measurements on ITER. These techniques allow operation of the diagnostics without a prohibitively large vibration isolated structure and permits the optics to be mounted directly on the radial port plugs on ITER. A beam path designed for 10.6 microm (CO2 laser) with a tangential path through the plasma allows both an interferometer and a Faraday rotation measurement of the line average density with good density resolution while avoiding refraction problems. Plasma effects on the probing beams and design tradeoffs will be discussed along with radiation and long pulse issues. A proposed layout of the diagnostic for ITER will be present

  19. Reliability measures in managing GI bleeding.

    Science.gov (United States)

    Sonnenberg, Amnon

    2012-06-01

    Multiple procedures and devices are used in a complex interplay to diagnose and treat GI bleeding. To model how a large variety of diagnostic and therapeutic components interact in the successful management of GI bleeding. The analysis uses the concept of reliability block diagrams from probability theory to model management outcome. Separate components of the management process are arranged in a serial or parallel fashion. If the outcome depends on the function of each component individually, such components are modeled to be arranged in series. If components complement each other and can mutually compensate for each of their failures, such components are arranged in a parallel fashion. General endoscopy practice. Patients with GI bleeding of unknown etiology. All available endoscopic and radiographic means to diagnose and treat GI bleeding. Process reliability in achieving hemostasis. Serial arrangements tend to reduce process reliability, whereas parallel arrangements increase it. Whenever possible, serial components should be bridged and complemented by additional alternative (parallel) routes of operation. Parallel components with low individual reliability can still contribute to overall process reliability as long as they function independently of other pre-existing alternatives. Probability of success associated with individual components is partly unknown. Modeling management of GI bleeding by a reliability block diagram provides a useful tool in assessing the impact of individual endoscopic techniques and administrative structures on the overall outcome. Copyright © 2012 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.

  20. A semi-automatic technique for measurement of arterial wall from black blood MRI

    International Nuclear Information System (INIS)

    Ladak, Hanif M.; Thomas, Jonathan B.; Mitchell, J. Ross; Rutt, Brian K.; Steinman, David A.

    2001-01-01

    Black blood magnetic resonance imaging (MRI) has become a popular technique for imaging the artery wall in vivo. Its noninvasiveness and high resolution make it ideal for studying the progression of early atherosclerosis in normal volunteers or asymptomatic patients with mild disease. However, the operator variability inherent in the manual measurement of vessel wall area from MR images hinders the reliable detection of relatively small changes in the artery wall over time. In this paper we present a semi-automatic method for segmenting the inner and outer boundary of the artery wall, and evaluate its operator variability using analysis of variance (ANOVA). In our approach, a discrete dynamic contour is approximately initialized by an operator, deformed to the inner boundary, dilated, and then deformed to the outer boundary. A group of four operators performed repeated measurements on 12 images from normal human subjects using both our semi-automatic technique and a manual approach. Results from the ANOVA indicate that the inter-operator standard error of measurement (SEM) of total wall area decreased from 3.254 mm2 (manual) to 1.293 mm2 (semi-automatic), and the intra-operator SEM decreased from 3.005 mm2 to 0.958 mm2. Operator reliability coefficients increased from less than 69% to more than 91% (inter-operator) and 95% (intra-operator). The minimum detectable change in wall area improved from more than 8.32 mm2 (intra-operator, manual) to less than 3.59 mm2 (inter-operator, semi-automatic), suggesting that it is better to have multiple operators measure wall area with our semi-automatic technique than to have a single operator make repeated measurements manually. Similar improvements in wall thickness and lumen radius measurements were also recorded. Since the semi-automatic technique has effectively ruled out the effect of the operator on these measurements, it may be possible to use such techniques to expand prospective studies of atherogenesis to multiple

  1. Supersonic shear imaging provides a reliable measurement of resting muscle shear elastic modulus

    International Nuclear Information System (INIS)

    Lacourpaille, Lilian; Hug, François; Bouillard, Killian; Nordez, Antoine; Hogrel, Jean-Yves

    2012-01-01

    The aim of the present study was to assess the reliability of shear elastic modulus measurements performed using supersonic shear imaging (SSI) in nine resting muscles (i.e. gastrocnemius medialis, tibialis anterior, vastus lateralis, rectus femoris, triceps brachii, biceps brachii, brachioradialis, adductor pollicis obliquus and abductor digiti minimi) of different architectures and typologies. Thirty healthy subjects were randomly assigned to the intra-session reliability (n = 20), inter-day reliability (n = 21) and the inter-observer reliability (n = 16) experiments. Muscle shear elastic modulus ranged from 2.99 (gastrocnemius medialis) to 4.50 kPa (adductor digiti minimi and tibialis anterior). On the whole, very good reliability was observed, with a coefficient of variation (CV) ranging from 4.6% to 8%, except for the inter-operator reliability of adductor pollicis obliquus (CV = 11.5%). The intraclass correlation coefficients were good (0.871 ± 0.045 for the intra-session reliability, 0.815 ± 0.065 for the inter-day reliability and 0.709 ± 0.141 for the inter-observer reliability). Both the reliability and the ease of use of SSI make it a potentially interesting technique that would be of benefit to fundamental, applied and clinical research projects that need an accurate assessment of muscle mechanical properties. (note)

  2. Application of a digital technique in evaluating the reliability of shade guides.

    Science.gov (United States)

    Cal, E; Sonugelen, M; Guneri, P; Kesercioglu, A; Kose, T

    2004-05-01

    There appears to be a need for a reliable method for quantification of tooth colour and analysis of shade. Therefore, the primary objective of this study was to show the applicability of graphic software in colour analysis and secondly to investigate the reliability of commercial shade guides produced by the same manufacturer, using this digital technique. After confirming the reliability and reproducibility of the digital method by using self-assessed coloured images, three shade guides of the same manufacturer were photographed in daylight and in studio environments with a digital camera and saved in tagged image file format (TIFF) format. Colour analysis of each photograph was performed using the Adobe Photoshop 4.0 graphic program. Luminosity, and red, green, blue (L and RGB) values of each shade tab of each shade guide were measured and the data were subjected to statistical analysis using the repeated measure Anova test. The L and RGB values of the images taken in daylight differed significantly from those of the images taken in studio environment (P < 0.05). In both environments, the luminosity and red values of the shade tabs were significantly different from each other (P < 0.05). It was concluded that, when the environmental conditions were kept constant, the Adobe Photoshop 4.0 colour analysis program could be used to analyse the colour of images. On the other hand, the results revealed that the accuracy of shade tabs widely being used in colour matching should be readdressed.

  3. Limits of reliability for the measurement of integral count

    International Nuclear Information System (INIS)

    Erbeszkorn, L.

    1979-01-01

    A method is presented for exact and approximate calculation of reliability limits of measured nuclear integral count. The formulae are applicable in measuring conditions which assure the Poisson distribution of the counts. The coefficients of the approximate formulae for 90, 95, 98 and 99 per cent reliability levels are given. The exact reliability limits for 90 per cent reliability level are calculated up to 80 integral counts. (R.J.)

  4. Reliability of Phase Velocity Measurements of Flexural Acoustic Waves in the Human Tibia In-Vivo.

    Science.gov (United States)

    Vogl, Florian; Schnüriger, Karin; Gerber, Hans; Taylor, William R

    2016-01-01

    Axial-transmission acoustics have shown to be a promising technique to measure individual bone properties and detect bone pathologies. With the ultimate goal being the in-vivo application of such systems, quantification of the key aspects governing the reliability is crucial to bring this method towards clinical use. This work presents a systematic reliability study quantifying the sources of variability and their magnitudes of in-vivo measurements using axial-transmission acoustics. 42 healthy subjects were measured by an experienced operator twice per week, over a four-month period, resulting in over 150000 wave measurements. In a complementary study to assess the influence of different operators performing the measurements, 10 novice operators were trained, and each measured 5 subjects on a single occasion, using the same measurement protocol as in the first part of the study. The estimated standard error for the measurement protocol used to collect the study data was ∼ 17 m/s (∼ 4% of the grand mean) and the index of dependability, as a measure of reliability, was Φ = 0.81. It was shown that the method is suitable for multi-operator use and that the reliability can be improved efficiently by additional measurements with device repositioning, while additional measurements without repositioning cannot improve the reliability substantially. Phase velocity values were found to be significantly higher in males than in females (p < 10-5) and an intra-class correlation coefficient of r = 0.70 was found between the legs of each subject. The high reliability of this non-invasive approach and its intrinsic sensitivity to mechanical properties opens perspectives for the rapid and inexpensive clinical assessment of bone pathologies, as well as for monitoring programmes without any radiation exposure for the patient.

  5. Reliability of horizontal and vertical tube shift techniques in the localisation of supernumerary teeth.

    Science.gov (United States)

    Mallineni, S K; Anthonappa, R P; King, N M

    2016-12-01

    To assess the reliability of the vertical tube shift technique (VTST) and horizontal tube shift technique (HTST) for the localisation of unerupted supernumerary teeth (ST) in the anterior region of the maxilla. A convenience sample of 83 patients who attended a major teaching hospital because of unerupted ST was selected. Only non-syndromic patients with ST and who had complete clinical and radiographic and surgical records were included in the study. Ten examiners independently rated the paired set of radiographs for each technique. Chi-square test, paired t test and kappa statistics were employed to assess the intra- and inter-examiner reliability. Paired sets of 1660 radiographs (830 pairs for each technique) were available for the analysis. The overall sensitivity for VTST and HTST was 80.6 and 72.1% respectively, with slight inter-examiner and good intra-examiner reliability. Statistically significant differences were evident between the two localisation techniques (p HTST in the anterior region of the maxilla.

  6. Measures of differences in reliability

    International Nuclear Information System (INIS)

    Doksum, K.A.

    1975-01-01

    Measures of differences in reliability of two systems are considered in the scale model, location-scale model, and a nonparametric model. In each model, estimates and confidence intervals are given and some of their properties discussed

  7. Reliability modeling of digital component in plant protection system with various fault-tolerant techniques

    International Nuclear Information System (INIS)

    Kim, Bo Gyung; Kang, Hyun Gook; Kim, Hee Eun; Lee, Seung Jun; Seong, Poong Hyun

    2013-01-01

    Highlights: • Integrated fault coverage is introduced for reflecting characteristics of fault-tolerant techniques in the reliability model of digital protection system in NPPs. • The integrated fault coverage considers the process of fault-tolerant techniques from detection to fail-safe generation process. • With integrated fault coverage, the unavailability of repairable component of DPS can be estimated. • The new developed reliability model can reveal the effects of fault-tolerant techniques explicitly for risk analysis. • The reliability model makes it possible to confirm changes of unavailability according to variation of diverse factors. - Abstract: With the improvement of digital technologies, digital protection system (DPS) has more multiple sophisticated fault-tolerant techniques (FTTs), in order to increase fault detection and to help the system safely perform the required functions in spite of the possible presence of faults. Fault detection coverage is vital factor of FTT in reliability. However, the fault detection coverage is insufficient to reflect the effects of various FTTs in reliability model. To reflect characteristics of FTTs in the reliability model, integrated fault coverage is introduced. The integrated fault coverage considers the process of FTT from detection to fail-safe generation process. A model has been developed to estimate the unavailability of repairable component of DPS using the integrated fault coverage. The new developed model can quantify unavailability according to a diversity of conditions. Sensitivity studies are performed to ascertain important variables which affect the integrated fault coverage and unavailability

  8. Infusing Reliability Techniques into Software Safety Analysis

    Science.gov (United States)

    Shi, Ying

    2015-01-01

    Software safety analysis for a large software intensive system is always a challenge. Software safety practitioners need to ensure that software related hazards are completely identified, controlled, and tracked. This paper discusses in detail how to incorporate the traditional reliability techniques into the entire software safety analysis process. In addition, this paper addresses how information can be effectively shared between the various practitioners involved in the software safety analyses. The author has successfully applied the approach to several aerospace applications. Examples are provided to illustrate the key steps of the proposed approach.

  9. Automatic ultrasound technique to measure angle of progression during labor.

    Science.gov (United States)

    Conversano, F; Peccarisi, M; Pisani, P; Di Paola, M; De Marco, T; Franchini, R; Greco, A; D'Ambrogio, G; Casciaro, S

    2017-12-01

    To evaluate the accuracy and reliability of an automatic ultrasound technique for assessment of the angle of progression (AoP) during labor. Thirty-nine pregnant women in the second stage of labor, with fetus in cephalic presentation, underwent conventional labor management with additional translabial sonographic examination. AoP was measured in a total of 95 acquisition sessions, both automatically by an innovative algorithm and manually by an experienced sonographer, who was blinded to the algorithm outcome. The results obtained from the manual measurement were used as the reference against which the performance of the algorithm was assessed. In order to overcome the common difficulties encountered when visualizing by sonography the pubic symphysis, the AoP was measured by considering as the symphysis landmark its centroid rather than its distal point, thereby assuring high measurement reliability and reproducibility, while maintaining objectivity and accuracy in the evaluation of progression of labor. There was a strong and statistically significant correlation between AoP values measured by the algorithm and the reference values (r = 0.99, P < 0.001). The high accuracy provided by the automatic method was also highlighted by the corresponding high values of the coefficient of determination (r 2  = 0.98) and the low residual errors (root mean square error = 2°27' (2.1%)). The global agreement between the two methods, assessed through Bland-Altman analysis, resulted in a negligible mean difference of 1°1' (limits of agreement, 4°29'). The proposed automatic algorithm is a reliable technique for measurement of the AoP. Its (relative) operator-independence has the potential to reduce human errors and speed up ultrasound acquisition time, which should facilitate management of women during labor. Copyright © 2017 ISUOG. Published by John Wiley & Sons Ltd. Copyright © 2017 ISUOG. Published by John Wiley & Sons Ltd.

  10. Use of variance techniques to measure dry air-surface exchange rates

    Science.gov (United States)

    Wesely, M. L.

    1988-07-01

    The variances of fluctuations of scalar quantities can be measured and interpreted to yield indirect estimates of their vertical fluxes in the atmospheric surface layer. Strong correlations among scalar fluctuations indicate a similarity of transfer mechanisms, which is utilized in some of the variance techniques. The ratios of the standard deviations of two scalar quantities, for example, can be used to estimate the flux of one if the flux of the other is measured, without knowledge of atmospheric stability. This is akin to a modified Bowen ratio approach. Other methods such as the normalized standard-deviation technique and the correlation-coefficient technique can be utilized effectively if atmospheric stability is evaluated and certain semi-empirical functions are known. In these cases, iterative calculations involving measured variances of fluctuations of temperature and vertical wind velocity can be used in place of direct flux measurements. For a chemical sensor whose output is contaminated by non-atmospheric noise, covariances with fluctuations of scalar quantities measured with a very good signal-to-noise ratio can be used to extract the needed standard deviation. Field measurements have shown that many of these approaches are successful for gases such as ozone and sulfur dioxide, as well as for temperature and water vapor, and could be extended to other trace substances. In humid areas, it appears that water vapor fluctuations often have a higher degree of correlation to fluctuations of other trace gases than do temperature fluctuations; this makes water vapor a more reliable companion or “reference” scalar. These techniques provide some reliable research approaches but, for routine or operational measurement, they are limited by the need for fast-response sensors. Also, all variance approaches require some independent means to estimate the direction of the flux.

  11. Reliability and criterion validity of an observation protocol for working technique assessments in cash register work.

    Science.gov (United States)

    Palm, Peter; Josephson, Malin; Mathiassen, Svend Erik; Kjellberg, Katarina

    2016-06-01

    We evaluated the intra- and inter-observer reliability and criterion validity of an observation protocol, developed in an iterative process involving practicing ergonomists, for assessment of working technique during cash register work for the purpose of preventing upper extremity symptoms. Two ergonomists independently assessed 17 15-min videos of cash register work on two occasions each, as a basis for examining reliability. Criterion validity was assessed by comparing these assessments with meticulous video-based analyses by researchers. Intra-observer reliability was acceptable (i.e. proportional agreement >0.7 and kappa >0.4) for 10/10 questions. Inter-observer reliability was acceptable for only 3/10 questions. An acceptable inter-observer reliability combined with an acceptable criterion validity was obtained only for one working technique aspect, 'Quality of movements'. Thus, major elements of the cashiers' working technique could not be assessed with an acceptable accuracy from short periods of observations by one observer, such as often desired by practitioners. Practitioner Summary: We examined an observation protocol for assessing working technique in cash register work. It was feasible in use, but inter-observer reliability and criterion validity were generally not acceptable when working technique aspects were assessed from short periods of work. We recommend the protocol to be used for educational purposes only.

  12. Gamma ray densitometry techniques for measuring of volume fractions

    International Nuclear Information System (INIS)

    Affonso, Renato Raoni Werneck; Silva, Ademir Xavier da; Salgado, Cesar Marques

    2015-01-01

    Knowledge of the volume fraction in a multiphase flow is of key importance in predicting the performance of many systems and processes. It is therefore an important parameter to characterize such flows. In the context of nuclear techniques, the gamma ray densitometry is promising and this is due to its non-invasive characteristics and very reliable results. It is used in several applications for multiphase flows (water-oil-air), which are employed tools such as: computational fluid dynamics, artificial neural networks and statistical methods of radiation transport, such as the Monte Carlo method. Based on the gamma radiation techniques for measurements of volume fractions, the aim of this paper is to present several techniques developed for this purpose. (author)

  13. Gamma ray densitometry techniques for measuring of volume fractions

    Energy Technology Data Exchange (ETDEWEB)

    Affonso, Renato Raoni Werneck; Silva, Ademir Xavier da; Salgado, Cesar Marques, E-mail: raoniwa@yahoo.com.br, E-mail: ademir@nuclear.ufrj.br, E-mail: otero@ien.gov.br [Instituto de Engenharia Nuclear (IEN/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2015-07-01

    Knowledge of the volume fraction in a multiphase flow is of key importance in predicting the performance of many systems and processes. It is therefore an important parameter to characterize such flows. In the context of nuclear techniques, the gamma ray densitometry is promising and this is due to its non-invasive characteristics and very reliable results. It is used in several applications for multiphase flows (water-oil-air), which are employed tools such as: computational fluid dynamics, artificial neural networks and statistical methods of radiation transport, such as the Monte Carlo method. Based on the gamma radiation techniques for measurements of volume fractions, the aim of this paper is to present several techniques developed for this purpose. (author)

  14. Clinical Utility of Ultrasound Measurements of Plantar Fascia Width and Cross-Sectional AreaA Novel Technique.

    Science.gov (United States)

    Bisi-Balogun, Adebisi; Rector, Michael

    2017-09-01

    We sought to develop a standardized protocol for ultrasound (US) measurements of plantar fascia (PF) width and cross-sectional area (CSA), which may serve as additional outcome variables during US examinations of both healthy asymptomatic PF and in plantar fasciopathy and determine its interrater and intrarater reliability. Ten healthy individuals (20 feet) were enrolled. Participants were assessed twice by two raters each to determine intrarater and interrater reliability. For each foot, three transverse scans of the central bundle of the PF were taken at its insertion at the medial calcaneal tubercle, identified in real time on the plantar surface of the foot, using a fine wire technique. Reliability was determined using intraclass correlation coefficients (ICC), standard errors of measurement (SEM), and limits of agreement (LOA) expressed as percentages of the mean. Reliability of PF width and CSA measurements was determined using PF width and CSA measurements from one sonogram measured once and the mean of three measurements from three sonograms each measured once. Ultrasound measurements of PF width and CSA showed a mean of 18.6 ± 2.0 mm and 69.20 ± 13.6 mm 2 respectively. Intra-reliability within both raters showed an ICC > 0.84 for width and ICC > 0.92 for CSA as well as a SEM% and LOA% < 10% for both width and CSA. Inter-rater reliability showed an ICC of 0.82 for width and 0.87 for CSA as well as a SEM% and LOA% < 10% for width and a SEM% < 10% and LOA% < 20% for CSA. Relative and absolute reliability within and between raters were higher when using the mean of three sonographs compared to one sonograph. Using this novel technique, PF CSA and width may be determined reliably using measurements from one sonogram or the mean of three sonograms. Measurement of PF CSA and width in addition to already established thickness and echogenicity measurements provides additional information on structural properties of the PF for clinicians and researchers in healthy

  15. How to Measure the Onset of Babbling Reliably?

    Science.gov (United States)

    Molemans, Inge; van den Berg, Renate; van Severen, Lieve; Gillis, Steven

    2012-01-01

    Various measures for identifying the onset of babbling have been proposed in the literature, but a formal definition of the exact procedure and a thorough validation of the sample size required for reliably establishing babbling onset is lacking. In this paper the reliability of five commonly used measures is assessed using a large longitudinal…

  16. The reliability of dual-energy X-ray absorptiometry measurements of bone mineral density in the metatarsals

    Energy Technology Data Exchange (ETDEWEB)

    Fuller, Joel T.; Buckley, Jonathan D.; Tsiros, Margarita D.; Thewlis, Dominic [University of South Australia, Alliance for Research in Exercise, Nutrition and Activity (ARENA), Sansom Institute for Health Research, GPO Box 2471, Adelaide, South Australia (Australia); Archer, Jane [University of South Australia, Medical Radiation, School of Health Sciences, Adelaide (Australia)

    2016-01-15

    To investigate the reliability of a simple, efficient technique for measuring bone mineral density (BMD) in the metatarsals using dual-energy X-ray absorptiometry (DXA). BMD of the right foot of 32 trained male distance runners was measured using a DXA scanner with the foot in the plantar position. Separate regions of interest (ROI) were used to assess the BMD of each metatarsal shaft (1st-5th) for each participant. ROI analysis was repeated by the same investigator to determine within-scan intra-rater reliability and by a different investigator to determine within-scan inter-rater reliability. Repeat DXA scans were undertaken for ten participants to assess between-scan intra-rater reliability. Assessment of BMD was consistently most reliable for the first metatarsal across all domains of reliability assessed (intra-class correlation coefficient [ICC] ≥0.97; coefficient of variation [CV] ≤1.5 %; limits of agreement [LOA] ≤4.2 %). Reasonable levels of intra-rater reliability were also achieved for the second and fifth metatarsals (ICC ≥0.90; CV ≤4.2 %; LOA ≤11.9 %). Poorer levels of reliability were demonstrated for the third (ICC ≥0.64; CV ≤8.2 %; LOA ≤23.6 %) and fourth metatarsals (ICC ≥0.67; CV ≤9.6 %; LOA ≤27.5 %). BMD was greatest in the first and second metatarsals (P < 0.01). Reliable measurements of BMD were achieved for the first, second and fifth metatarsals. (orig.)

  17. The reliability of dual-energy X-ray absorptiometry measurements of bone mineral density in the metatarsals

    International Nuclear Information System (INIS)

    Fuller, Joel T.; Buckley, Jonathan D.; Tsiros, Margarita D.; Thewlis, Dominic; Archer, Jane

    2016-01-01

    To investigate the reliability of a simple, efficient technique for measuring bone mineral density (BMD) in the metatarsals using dual-energy X-ray absorptiometry (DXA). BMD of the right foot of 32 trained male distance runners was measured using a DXA scanner with the foot in the plantar position. Separate regions of interest (ROI) were used to assess the BMD of each metatarsal shaft (1st-5th) for each participant. ROI analysis was repeated by the same investigator to determine within-scan intra-rater reliability and by a different investigator to determine within-scan inter-rater reliability. Repeat DXA scans were undertaken for ten participants to assess between-scan intra-rater reliability. Assessment of BMD was consistently most reliable for the first metatarsal across all domains of reliability assessed (intra-class correlation coefficient [ICC] ≥0.97; coefficient of variation [CV] ≤1.5 %; limits of agreement [LOA] ≤4.2 %). Reasonable levels of intra-rater reliability were also achieved for the second and fifth metatarsals (ICC ≥0.90; CV ≤4.2 %; LOA ≤11.9 %). Poorer levels of reliability were demonstrated for the third (ICC ≥0.64; CV ≤8.2 %; LOA ≤23.6 %) and fourth metatarsals (ICC ≥0.67; CV ≤9.6 %; LOA ≤27.5 %). BMD was greatest in the first and second metatarsals (P < 0.01). Reliable measurements of BMD were achieved for the first, second and fifth metatarsals. (orig.)

  18. The reliability of dual-energy X-ray absorptiometry measurements of bone mineral density in the metatarsals.

    Science.gov (United States)

    Fuller, Joel T; Archer, Jane; Buckley, Jonathan D; Tsiros, Margarita D; Thewlis, Dominic

    2016-01-01

    To investigate the reliability of a simple, efficient technique for measuring bone mineral density (BMD) in the metatarsals using dual-energy X-ray absorptiometry (DXA). BMD of the right foot of 32 trained male distance runners was measured using a DXA scanner with the foot in the plantar position. Separate regions of interest (ROI) were used to assess the BMD of each metatarsal shaft (1st-5th) for each participant. ROI analysis was repeated by the same investigator to determine within-scan intra-rater reliability and by a different investigator to determine within-scan inter-rater reliability. Repeat DXA scans were undertaken for ten participants to assess between-scan intra-rater reliability. Assessment of BMD was consistently most reliable for the first metatarsal across all domains of reliability assessed (intra-class correlation coefficient [ICC] ≥0.97; coefficient of variation [CV] ≤1.5%; limits of agreement [LOA] ≤4.2%). Reasonable levels of intra-rater reliability were also achieved for the second and fifth metatarsals (ICC ≥0.90; CV ≤4.2%; LOA ≤11.9%). Poorer levels of reliability were demonstrated for the third (ICC ≥0.64; CV ≤8.2%; LOA ≤23.6%) and fourth metatarsals (ICC ≥0.67; CV ≤9.6%; LOA ≤27.5%). BMD was greatest in the first and second metatarsals (P Reliable measurements of BMD were achieved for the first, second and fifth metatarsals.

  19. The Reliability of Anthropometric Measurements Used Preoperatively in Aesthetic Breast Surgery.

    Science.gov (United States)

    Isaac, Kathryn V; Murphy, Blake D; Beber, Brett; Brown, Mitchell

    2016-04-01

    Patient outcomes in aesthetic breast surgery are highly dependent on breast measurements used in preoperative planning. The purpose of this study is to determine the reliability of anthropometric breast measurements. Four raters measured 28 women using 7 measurements: sternal notch to nipple distance (Sn-N), nipple to midline (N-M), nipple to inframammary-fold distance under maximal stretch (N-IMF), breast base width (BW), soft tissue pinch thickness of the upper pole (STPT:UP), STPT at the inframammary fold (STPT:IMF), and anterior pull skin stretch (APSS). Reliability was assessed using intra-class correlation coefficients (ICCs). Inter-rater reliability was excellent for Sn-N, N-M, and BW (ICC = 0.94, 0.90, and 0.76, respectively) and was good for N-IMF (ICC = 0.70). The STPT:UP, STPT:IMF, and APSS measurements were not reliable between raters (ICC reliability was excellent for Sn-N, N-M, and BW for all raters (all ICC > 0.75). The N-IMF intra-rater reliability was excellent in senior raters (ICC > 0.75) and good in junior raters (ICC > 0.6). The STPT:UP, STPT:IMF, and APSS measurements showed fair or poor reliability for most raters (ICC reliable. Dynamic measurements including APSS, STPT:UP, and STUP:IMF are unreliable. N-IMF is the only reliable dynamic measurement, and its reliability improves with increasing clinical experience. The variable reliability of preoperative measurements must be considered in the planning of aesthetic breast surgery. 4 Diagnostic. © 2015 The American Society for Aesthetic Plastic Surgery, Inc. Reprints and permission: journals.permissions@oup.com.

  20. Reliability of the Superimposed-Burst Technique in Patients With Patellofemoral Pain: A Technical Report.

    Science.gov (United States)

    Norte, Grant E; Frye, Jamie L; Hart, Joseph M

    2015-11-01

    The superimposed-burst (SIB) technique is commonly used to quantify central activation failure after knee-joint injury, but its reliability has not been established in pathologic cohorts. To assess within-session and between-sessions reliability of the SIB technique in patients with patellofemoral pain. Descriptive laboratory study. University laboratory. A total of 10 patients with self-reported patellofemoral pain (1 man, 9 women; age = 24.1 ± 3.8 years, height = 167.8 ± 15.2 cm, mass = 71.6 ± 17.5 kg) and 10 healthy control participants (3 men, 7 women; age = 27.4 ± 5.0 years, height = 173.5 ± 9.9 cm, mass = 78.2 ± 16.5 kg) volunteered. Participants were assessed at 6 intervals spanning 21 days. Intraclass correlation coefficients (ICCs [3,3]) were used to assess reliability. Quadriceps central activation ratio, knee-extension maximal voluntary isometric contraction force, and SIB force. The quadriceps central activation ratio was highly reliable within session (ICC [3,3] = 0.97) and between sessions through day 21 (ICC [3,3] = 0.90-0.95). Acceptable reliability of knee extension (ICC [3,3] = 0.75-0.91) and SIB force (ICC [3,3] = 0.77-0.89) was observed through day 21. The SIB technique was reliable for clinical research up to 21 days in patients with patellofemoral pain.

  1. Techniques to maximize software reliability in radiation fields

    International Nuclear Information System (INIS)

    Eichhorn, G.; Piercey, R.B.

    1986-01-01

    Microprocessor system failures due to memory corruption by single event upsets (SEUs) and/or latch-up in RAM or ROM memory are common in environments where there is high radiation flux. Traditional methods to harden microcomputer systems against SEUs and memory latch-up have usually involved expensive large scale hardware redundancy. Such systems offer higher reliability, but they tend to be more complex and non-standard. At the Space Astronomy Laboratory the authors have developed general programming techniques for producing software which is resistant to such memory failures. These techniques, which may be applied to standard off-the-shelf hardware, as well as custom designs, include an implementation of Maximally Redundant Software (MRS) model, error detection algorithms and memory verification and management

  2. Test-retest reliability for aerodynamic measures of voice.

    Science.gov (United States)

    Awan, Shaheen N; Novaleski, Carolyn K; Yingling, Julie R

    2013-11-01

    The purpose of this study was to investigate the intrasubject reliability of aerodynamic characteristics of the voice within typical/normal speakers across testing sessions using the Phonatory Aerodynamic System (PAS 6600; KayPENTAX, Montvale, NJ). Participants were 60 healthy young adults (30 males and 30 females) between the ages 18 and 31 years with perceptually typical voice. Participants were tested using the PAS 6600 (Phonatory Aerodynamic System) on two separate days with approximately 1 week between each session at approximately the same time of day. Four PAS protocols were conducted (vital capacity, maximum sustained phonation, comfortable sustained phonation, and voicing efficiency) and measures of expiratory volume, maximum phonation time, mean expiratory airflow (during vowel production) and target airflow (obtained via syllable repetition), peak air pressure, aerodynamic power, aerodynamic resistance, and aerodynamic efficiency were obtained during each testing session. Associated acoustic measures of vocal intensity and frequency were also collected. All phonations were elicited at comfortable pitch and loudness. All aerodynamic and associated variables evaluated in this study showed useable test-retest reliability (ie, intraclass correlation coefficients [ICCs] ≥ 0.60). A high degree of mean test-retest reliability was found across all subjects for aerodynamic and associated acoustic measurements of vital capacity, maximum sustained phonation, glottal resistance, and vocal intensity (all with ICCs > 0.75). Although strong ICCs were observed for measures of glottal power and mean expiratory airflow in males, weaker overall results for these measures (ICC range: 0.60-0.67) were observed in females subjects and sizable coefficients of variation were observed for measures of power, resistance, and efficiency in both men and women. Differences in degree of reliability from measure to measure were revealed in greater detail using methods such as ICCs and

  3. Electropyroelectric technique for measurement of the thermal effusivity of liquids

    Energy Technology Data Exchange (ETDEWEB)

    Ivanov, R; Moreno, I; Araujo, C [Facultad de Fisica, Universidad Autonoma de Zacatecas, Calz. Solidaridad Esquina Paseo de la Bufa s/n, C. P. 98060, Zacatecas, Zac. (Mexico); Marin, E, E-mail: emarin63@yahoo.e, E-mail: emarinm@ipn.m [Centro de Investigacion en Ciencia Aplicada y TecnologIa Avanzada, Instituto Politecnico Nacional, LegarIa 694, Colonia Irrigacion, C. P. 11500, Mexico D. F. (Mexico)

    2010-06-09

    The photopyroelectric method has been recognized as a reliable and useful tool for the measurement of the thermal properties of condensed matter samples. Usually the photothermal signal is generated using intensity modulated light beams, whose amplitudes are difficult to maintain stable. In this paper we describe a variant of this technique that uses amplitude modulated electrical current as excitation source, via Joule heating of the metal contact on one side of the pyroelectric sensor. The possibilities of this method, called by us the electropyroelectric technique, for thermal effusivity measurements of liquid samples are shown using test samples of distilled water, ethanol and glycerine. The results obtained for this parameter agree well with the values reported in the literature. Our measurement uncertainties are about 3%, a fact that opens several possible applications.

  4. Electropyroelectric technique for measurement of the thermal effusivity of liquids

    International Nuclear Information System (INIS)

    Ivanov, R; Moreno, I; Araujo, C; Marin, E

    2010-01-01

    The photopyroelectric method has been recognized as a reliable and useful tool for the measurement of the thermal properties of condensed matter samples. Usually the photothermal signal is generated using intensity modulated light beams, whose amplitudes are difficult to maintain stable. In this paper we describe a variant of this technique that uses amplitude modulated electrical current as excitation source, via Joule heating of the metal contact on one side of the pyroelectric sensor. The possibilities of this method, called by us the electropyroelectric technique, for thermal effusivity measurements of liquid samples are shown using test samples of distilled water, ethanol and glycerine. The results obtained for this parameter agree well with the values reported in the literature. Our measurement uncertainties are about 3%, a fact that opens several possible applications.

  5. Reliability of infrared thermometric measurements of skin temperature in the hand.

    Science.gov (United States)

    Packham, Tara L; Fok, Diana; Frederiksen, Karen; Thabane, Lehana; Buckley, Norman

    2012-01-01

    Clinical measurement study. Skin temperature asymmetries (STAs) are used in the diagnosis of complex regional pain syndrome (CRPS), but little evidence exists for reliability of the equipment and methods. This study examined the reliability of an inexpensive infrared (IR) thermometer and measurement points in the hand for the study of STA. ST was measured three times at five points on both hands with an IR thermometer by two raters in 20 volunteers (12 normals and 8 CRPS). ST measurement results using IR thermometers support inter-rater reliability: intraclass correlation coefficient (ICC) estimate for single measures 0.80; all ST measurement points were also highly reliable (ICC single measures, 0.83-0.91). The equipment demonstrated excellent reliability, with little difference in the reliability of the five measurement sites. These preliminary findings support their use in future CRPS research. Not applicable. Copyright © 2012 Hanley & Belfus. Published by Elsevier Inc. All rights reserved.

  6. TWO CRITERIA FOR GOOD MEASUREMENTS IN RESEARCH: VALIDITY AND RELIABILITY

    Directory of Open Access Journals (Sweden)

    Haradhan Kumar Mohajan

    2017-12-01

    Full Text Available Reliability and validity are two most important and fundamental features in the evaluation of any measurement instrument or toll for a good research. The purpose of this research is to discuss the validity and reliability of measurement instruments that are used in research. Validity concerns what an instrument measures, and how well it does so. Reliability concerns the faith that one can have in the data obtained from use of an instrument, that is, the degree to which any measuring tool controls for random error. An attempt has been taken here to review the reliability and validity, and threat to them in some details.

  7. Pneumothorax size measurements on digital chest radiographs: Intra- and inter- rater reliability.

    Science.gov (United States)

    Thelle, Andreas; Gjerdevik, Miriam; Grydeland, Thomas; Skorge, Trude D; Wentzel-Larsen, Tore; Bakke, Per S

    2015-10-01

    Detailed and reliable methods may be important for discussions on the importance of pneumothorax size in clinical decision-making. Rhea's method is widely used to estimate pneumothorax size in percent based on chest X-rays (CXRs) from three measure points. Choi's addendum is used for anterioposterior projections. The aim of this study was to examine the intrarater and interrater reliability of the Rhea and Choi method using digital CXR in the ward based PACS monitors. Three physicians examined a retrospective series of 80 digital CXRs showing pneumothorax, using Rhea and Choi's method, then repeated in a random order two weeks later. We used the analysis of variance technique by Eliasziw et al. to assess the intrarater and interrater reliability in altogether 480 estimations of pneumothorax size. Estimated pneumothorax sizes ranged between 5% and 100%. The intrarater reliability coefficient was 0.98 (95% one-sided lower-limit confidence interval C 0.96), and the interrater reliability coefficient was 0.95 (95% one-sided lower-limit confidence interval 0.93). This study has shown that the Rhea and Choi method for calculating pneumothorax size has high intrarater and interrater reliability. These results are valid across gender, side of pneumothorax and whether the patient is diagnosed with primary or secondary pneumothorax. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  8. Development of a computational technique to measure cartilage contact area.

    Science.gov (United States)

    Willing, Ryan; Lapner, Michael; Lalone, Emily A; King, Graham J W; Johnson, James A

    2014-03-21

    Computational measurement of joint contact distributions offers the benefit of non-invasive measurements of joint contact without the use of interpositional sensors or casting materials. This paper describes a technique for indirectly measuring joint contact based on overlapping of articular cartilage computer models derived from CT images and positioned using in vitro motion capture data. The accuracy of this technique when using the physiological nonuniform cartilage thickness distribution, or simplified uniform cartilage thickness distributions, is quantified through comparison with direct measurements of contact area made using a casting technique. The efficacy of using indirect contact measurement techniques for measuring the changes in contact area resulting from hemiarthroplasty at the elbow is also quantified. Using the physiological nonuniform cartilage thickness distribution reliably measured contact area (ICC=0.727), but not better than the assumed bone specific uniform cartilage thicknesses (ICC=0.673). When a contact pattern agreement score (s(agree)) was used to assess the accuracy of cartilage contact measurements made using physiological nonuniform or simplified uniform cartilage thickness distributions in terms of size, shape and location, their accuracies were not significantly different (p>0.05). The results of this study demonstrate that cartilage contact can be measured indirectly based on the overlapping of cartilage contact models. However, the results also suggest that in some situations, inter-bone distance measurement and an assumed cartilage thickness may suffice for predicting joint contact patterns. Copyright © 2014 Elsevier Ltd. All rights reserved.

  9. Reliability of ultrasonographic measurements in suspected patients of developmental dysplasia of the hip and correlation with the acetabular index

    Directory of Open Access Journals (Sweden)

    Cem Copuroglu

    2011-01-01

    Full Text Available Background: Ultrasonography is accepted as a useful imaging modality in the early detection of developmental dysplasia of the hip (DDH. Early detection and early treatment of DDH prevents hip dislocation and related physical, social, economic, and psychological problems. The purpose of this study was to evaluate the reliability of ultrasonographic and roentgenographic measurements measured by seven different observers. Materials and Methods: The alpha angles of 66 hips in 33 patients were measured using the Graf method by seven different observers. Acetabular index degrees on plane roentgenograms were measured in order to assess the correlation between the ultrasonographic alpha angle and the radiographic acetabular index, which both show the bony acetabular depth, retrospectively. Results: The interclass correlation coefficient, measuring the interobserver reliability, was high and statistically significant for the ultrasonographic measurements. There was a negative correlation between the alpha angle and the acetabular index. Conclusions: Ultrasonography, when applied properly, is a reliable technique between different observers, in the diagnosis and follow up of DDH. When assessed concomitantly with the roentgenographic measurements, the results are reliable and statistically meaningful.

  10. The Reliability of Isometer 2 Device in Measuring of Cervical Flexor and Extensor Muscles Strength

    Directory of Open Access Journals (Sweden)

    Asghar Reza Soltan-Zadeh

    2006-07-01

    Full Text Available Objective: The strength of a group of muscles can be measured by muscle strength test, employing a force measuring instrument. In order to monitor the effectiveness of a therapeutic or training programs we need a reliable technique which is also accurate in repeated measurements. The purpose of this study was to examine the reliability of an isometric neck muscle force measurement device.  Materials & Methods: Thirty seven healthy non athlete subjects (18 males and 19 females, aged 18-25 participated in this analytical study. The maximal isometric contractions of the neck extensor and flexor muscles were measured in different times and different days and by two different testers. A new sensitive “load cell” was applied to our previously designed neck muscle force measurement apparatus. Results: The results of the inter-trail, test retest, and inter rater reliability (0.86 < ICC < 0.98 , 2.2< Sw <5.1 N indicated that the neck muscle force measurements were highly repeatable and less variable between measurements. There were no statistically significant differences in neck muscle force measurements, between times, between days and between retsters. Maximum isometric contractions were significantly higher in males than in the females (p < 0.001. Women’s neck muscle strengths were 30.8% and 46.1% of men in cervical extension and cervical flexion. Conclusion: In this study we used a new model (Isometer 2 of our previous apparatus (Isometer. The isometric strength of neck flexor and extensor muscles which was measured by Isometer 2 appeared to be a reliable and useful method for measuring the force of the neck extensor and flexor muscles.

  11. Reliability of twin-dependent triple junction distributions measured from a section plane

    International Nuclear Information System (INIS)

    Hardy, Graden B.; Field, David P.

    2016-01-01

    Numerous studies indicate polycrystalline triple junctions are independent microstructural features with distinct properties from their constituent grain boundaries. Despite the influence of triple junctions on material properties, it is impractical to characterize triple junctions on a large scale using current three-dimensional methods. This work demonstrates the ability to characterize twin-dependent triple junction distributions from a section plane by adopting a grain boundary plane stereology. The technique is validated through simulated distributions and simulated electron back-scatter diffraction (EBSD) data. Measures of validation and convergence are adopted to demonstrate the quantitative reliability of the technique as well as the convergence behavior of twin-dependent triple junction distributions. This technique expands the characterization power of EBSD and prepares the way for characterizing general triple junction distributions from a section plane. - Graphical abstract: The distribution of planes forming a triple junction with a given twin boundary is shown partially in the stereographic projections below from a given projection. The plot on the left shows the ideal/measured distribution and the plot on the right shows the distribution obtained from the stereological method presented here.

  12. Measuring Passenger Travel Time Reliability using Smartcard Data

    NARCIS (Netherlands)

    Bagherian, M.; Cats, O.; van Oort, N.; Hickman, M

    2016-01-01

    Service reliability is a key performance measure for transit agencies in increasing their service quality and thus ridership. Conventional reliability metrics are established based on vehicle movements and thus do not adequately reflect passenger’s experience. In the past few years, the growing

  13. Reliability and validity in measurement of true humeral retroversion by a three-dimensional cylinder fitting method.

    Science.gov (United States)

    Saka, Masayuki; Yamauchi, Hiroki; Hoshi, Kenji; Yoshioka, Toru; Hamada, Hidetoshi; Gamada, Kazuyoshi

    2015-05-01

    Humeral retroversion is defined as the orientation of the humeral head relative to the distal humerus. Because none of the previous methods used to measure humeral retroversion strictly follow this definition, values obtained by these techniques vary and may be biased by morphologic variations of the humerus. The purpose of this study was 2-fold: to validate a method to define the axis of the distal humerus with a virtual cylinder and to establish the reliability of 3-dimensional (3D) measurement of humeral retroversion by this cylinder fitting method. Humeral retroversion in 14 baseball players (28 humeri) was measured by the 3D cylinder fitting method. The root mean square error was calculated to compare values obtained by a single tester and by 2 different testers using the embedded coordinate system. To establish the reliability, intraclass correlation coefficient (ICC) and precision (standard error of measurement [SEM]) were calculated. The root mean square errors for the humeral coordinate system were reliability and precision of the 3D measurement of retroversion yielded an intratester ICC of 0.99 (SEM, 1.0°) and intertester ICC of 0.96 (SEM, 2.8°). The error in measurements obtained by a distal humerus cylinder fitting method was small enough not to affect retroversion measurement. The 3D measurement of retroversion by this method provides excellent intratester and intertester reliability. Copyright © 2015 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  14. Reliability importance measures and their calculation

    International Nuclear Information System (INIS)

    Andsten, R.; Vaurio, J.K.

    1989-01-01

    The importance of a component to the system reliability or availability and to the system failure rate can be measured by a number of importance measures. Such measures can be used to guide the system design improvement actions as well as the diagnostic and repair actions. This report develops relationships between several importance measures, illustrates their meaning with interpretations and applications, and describes the computer program called IMPO that calculates importance measures when the system minimum cat sets and component parameters are given. A user's manual is included with illustrative examples

  15. Airway resistance measurements in pre-school children with asthmatic symptoms : The interrupter technique

    NARCIS (Netherlands)

    Kooi, EMW; Schokker, S; van der Molen, T; Duiverman, EJ

    Measuring airway resistance in pre-school children with the interrupter technique has proven to be feasible and reliable in daily clinical practice and research settings. Whether it contributes to diagnosing asthma in pre-schoot children still remains uncertain. From the results of previous studies

  16. System safety and reliability using object-oriented programming techniques

    International Nuclear Information System (INIS)

    Patterson-Hine, F.A.; Koen, B.V.

    1987-01-01

    Direct evaluation fault tree codes have been written in recursive, list-processing computer languages such as PL/1 (PATREC-I) and LISP (PATREC-L). The pattern-matching strategy implemented in these codes has been used extensively in France to evaluate system reliability. Recent reviews of the risk management process suggest that a data base containing plant-specific information be integrated with a package of codes used for probabilistic risk assessment (PRA) to alleviate some of the difficulties that make a PRA so costly and time-intensive. A new programming paradigm, object-oriented programming, is uniquely suited for the development of such a software system. A knowledge base and fault tree evaluation algorithm, based on previous experience with PATREC-L, have been implemented using object-oriented techniques, resulting in a reliability assessment environment that is easy to develop, modify, and extend

  17. Computer Aided Measurement Laser (CAML): technique to quantify post-mastectomy lymphoedema

    International Nuclear Information System (INIS)

    Trombetta, Chiara; Abundo, Paolo; Felici, Antonella; Ljoka, Concetta; Foti, Calogero; Cori, Sandro Di; Rosato, Nicola

    2012-01-01

    Lymphoedema can be a side effect of cancer treatment. Eventhough several methods for assessing lymphoedema are used in clinical practice, an objective quantification of lymphoedema has been problematic. The aim of the study was to determine the objectivity, reliability and repeatability of the computer aided measurement laser (CAML) technique. CAML technique is based on computer aided design (CAD) methods and requires an infrared laser scanner. Measurements are scanned and the information describing size and shape of the limb allows to design the model by using the CAD software. The objectivity and repeatability was established in the beginning using a phantom. Consequently a group of subjects presenting post-breast cancer lymphoedema was evaluated using as a control the contralateral limb. Results confirmed that in clinical settings CAML technique is easy to perform, rapid and provides meaningful data for assessing lymphoedema. Future research will include a comparison of upper limb CAML technique between healthy subjects and patients with known lymphoedema.

  18. Intrarater and interrater reliability for measurements in videofluoroscopy of swallowing

    International Nuclear Information System (INIS)

    Baijens, Laura; Barikroo, Ali; Pilz, Walmari

    2013-01-01

    Objective: Intrarater and interrater reliability is crucial to the quality of diagnostic and therapy-effect studies. This paper reports on a systematic review of studies on intrarater and interrater reliability for measurements in videofluoroscopy of swallowing. The aim of this review was to summarize and qualitatively analyze published studies on that topic. Materials and methods: Those published up to March 2013 were found through a comprehensive electronic database search using PubMed, Embase, and The Cochrane Library. Two reviewers independently assessed the studies using strict inclusion criteria. Results: Nineteen studies were included and then qualitatively analyzed. In several of these, methodological problems were found. Moreover, intrarater and interrater reliability varied with the measure applied. A meta-analysis was not carried out as studies were not of sufficient quality to warrant doing so. Conclusion: In order to achieve reliable measurements in videofluoroscopy of swallowing, it is recommended that raters use well-defined guidelines for the levels of ordinal visuoperceptual variables. Furthermore, in order to make the measurements reliable (intrarater and interrater) it is recommended that, following protocolled pre-experimental training, the raters should have maximum consensus about the definition of the measured variables

  19. Intrarater and interrater reliability for measurements in videofluoroscopy of swallowing

    Energy Technology Data Exchange (ETDEWEB)

    Baijens, Laura, E-mail: laura.baijens@mumc.nl [Department of Otorhinolaryngology, Head and Neck Surgery, Maastricht University Medical Center, Maastricht (Netherlands); Barikroo, Ali, E-mail: a.Barikroo@ufl.edu [Swallowing Research Laboratory, Department of Speech, Language and Hearing Sciences, College of Public Health and Health Professions, University of Florida, Gainesville, FL (United States); Pilz, Walmari, E-mail: walmari.pilz@mumc.nl [Department of Otorhinolaryngology, Head and Neck Surgery, Maastricht University Medical Center, Maastricht (Netherlands)

    2013-10-01

    Objective: Intrarater and interrater reliability is crucial to the quality of diagnostic and therapy-effect studies. This paper reports on a systematic review of studies on intrarater and interrater reliability for measurements in videofluoroscopy of swallowing. The aim of this review was to summarize and qualitatively analyze published studies on that topic. Materials and methods: Those published up to March 2013 were found through a comprehensive electronic database search using PubMed, Embase, and The Cochrane Library. Two reviewers independently assessed the studies using strict inclusion criteria. Results: Nineteen studies were included and then qualitatively analyzed. In several of these, methodological problems were found. Moreover, intrarater and interrater reliability varied with the measure applied. A meta-analysis was not carried out as studies were not of sufficient quality to warrant doing so. Conclusion: In order to achieve reliable measurements in videofluoroscopy of swallowing, it is recommended that raters use well-defined guidelines for the levels of ordinal visuoperceptual variables. Furthermore, in order to make the measurements reliable (intrarater and interrater) it is recommended that, following protocolled pre-experimental training, the raters should have maximum consensus about the definition of the measured variables.

  20. Reliability of radiographic measurement of lateral capitellohumeral angle in healthy children.

    Science.gov (United States)

    Hasegawa, Masaki; Suzuki, Taku; Kuroiwa, Takashi; Oka, Yusuke; Maeda, Atsushi; Takeda, Hiroki; Shizu, Kanae; Tsuji, Takashi; Suzuki, Katsuji; Yamada, Harumoto

    2018-04-01

    This retrospective cohort study was designed to validate the reliability of measurement of the lateral capitellohumeral angle (LCHA), an index of sagittal angulation of the elbow, in healthy children. The results were compared to the Baumann angle (BA), which is a similar concept to LCHA.Sixty-two radiographs of the elbow in healthy children (range, 2-11 years) were reviewed by 6 examiners at 2 sessions. The mean value and reliability of the measurement of LCHA and BA were assessed. Intraobserver reliability and interobserver reliability were calculated using intraclass correlation coefficients (ICCs).The mean LCHA value was 45° (range, 22° to 70°) and the mean BA was 71° (range, 56° to 86°). The ICCs for intraobserver reliability of the LCHA measurements were almost perfect for 2 examiners, substantial for 3 examiners, and moderate for 1 examiner with a mean value of 0.77 (range, 0.57-0.95). For BA measurements, the ICCs were almost perfect for 1 examiner and substantial for 5 examiners with a mean value of 0.74 (range, 0.66-0.83). The ICCs for interobserver reliability between the first and second measurements were both moderate for LCHA (0.56 and 0.51) and for BA (0.52 and 0.50).LCHA showed almost the same reliability in measurement as BA, which is the gold standard assessment for coronal alignment of the elbow. LCHA showed moderate-to-good reliability in the evaluation of sagittal plane elbow alignment.

  1. Techniques and applications of the human reliability analysis in nuclear facilities

    International Nuclear Information System (INIS)

    Pinto, Fausto C.

    1995-01-01

    The analysis and prediction of the man-machine interaction are the objectives of human reliability analysis. In this work is presented in a manner that could be used by experts in the field of Probabilistic Safety Assessment, considering primarily the aspects of human errors. The Technique of Human Error Rate Prediction (THERP) is used in large scale to obtain data on human error. Applications of this technique are presented, as well as aspects of the state-of-art and of research and development of this particular field of work, where the construction of a reliable data bank is considered essential. In this work is also developed an application of the THERP for the TRIGA Mark 1 IPR R-1 Reactor of the Centro de Desenvolvimento de Tecnologia Nuclear, Brazilian research institute of nuclear technology. The results indicate that some changes must be made in the emergency procedures of the reactor, in order to achieve a higher level of safety

  2. Effectiveness and reliability of US inservice inspection techniques

    International Nuclear Information System (INIS)

    Doctor, S.R.; Becker, F.L.; Selby, G.P.

    1982-01-01

    The work presented is from an ongoing program directed toward measuring the effectiveness and reliability of inservice inspection (ISI) of light water reactor systems (primary piping and pressure vessel). Extensive round robin and parametric evaluations have been conducted in 10 in. Sch. 80 stainless steel as well as centrifugally cast stainless steel and clad ferritic main coolant pipe welds. Results from these measurements will be viewed in relationship to US regulations and ASME Section XI Code requirements. 6 figures

  3. Development of Uncertainty Quantification Method for MIR-PIV Measurement using BOS Technique

    International Nuclear Information System (INIS)

    Seong, Jee Hyun; Song, Min Seop; Kim, Eung Soo

    2014-01-01

    Matching Index of Refraction (MIR) is frequently used for obtaining high quality PIV measurement data. ven small distortion by unmatched refraction index of test section can result in uncertainty problems. In this context, it is desirable to construct new concept for checking errors of MIR and following uncertainty of PIV measurement. This paper proposes a couple of experimental concept and relative results. This study developed an MIR uncertainty quantification method for PIV measurement using SBOS technique. From the reference data of the BOS, the reliable SBOS experiment procedure was constructed. Then with the combination of SBOS technique with MIR-PIV technique, velocity vector and refraction displacement vector field was measured simultaneously. MIR errors are calculated through mathematical equation, in which PIV and SBOS data are put. These errors are also verified by another BOS experiment. Finally, with the applying of calculated MIR-PIV uncertainty, correct velocity vector field can be obtained regardless of MIR errors

  4. Description and Evaluation of a Measurement Technique for Assessment of Performing Gender

    Science.gov (United States)

    Harris, Kathleen Mullan; Halpern, Carolyn Tucker

    2016-01-01

    The influence of masculinity and femininity on behaviors and outcomes has been extensively studied in social science research using various measurement strategies. In the present paper, we describe and evaluate a measurement technique that uses existing survey items to capture the extent to which an individual behaves similarly to their same-gender peers. We use data from the first four waves of The National Longitudinal Study of Adolescent to Adult Health (Add Health), a nationally representative sample of adolescents (age 12–18) in the United States who were re-interviewed at ages 13–19, 18–26, and 24–32. We estimate split-half reliability and provide evidence that supports the validity of this measurement technique. We demonstrate that the resulting measure does not perform as a trait measure and is associated with involvement in violent fights, a pattern consistent with theory and empirical findings. This measurement technique represents a novel approach for gender researchers with the potential for expanding our current knowledge base. PMID:28630528

  5. Pulse holographic measurement techniques

    International Nuclear Information System (INIS)

    Kim, Cheol Jung; Baik, Seong Hoon; Hong, Seok Kyung; Kim, Jeong Moog; Kim, Duk Hyun

    1992-01-01

    With the development of laser, remote inspection techniques using laser have been growing on. The inspection and measurement techniques by pulse holography are well-established technique for precise measurement, and widely used in various fields of industry now. In nuclear industry, this technology is practically used because holographic inspection is remote, noncontact, and precise measurement technique. In relation to remote inspection technology in nuclear industry, state-of-the art of pulse HNDT (Holographic non-destructive testing) and holographic measurement techniques are examined. First of all, the fundamental principles as well as practical problems for applications are briefly described. The fields of pulse holography have been divided into the HNDT, flow visualization and distribution study, and other application techniques. Additionally holographic particle study, bubble chamber holography, and applications to other visualization techniques are described. Lastly, the current status for the researches and applications of pulse holography to nuclear industry which are carried out actively in Europe and USA, is described. (Author)

  6. Intercomparison test of various aerosol measurement techniques

    International Nuclear Information System (INIS)

    Cherdron, W.; Hassa, C.; Jordan, S.

    1984-01-01

    At the suggestion of the CONT group (Containment Loading and Response), which is a subgroup of the Safety Working Group of the Fast Reactor Coordinating Committee, a group of experts undertook a comparison of the techniques of sodium aerosol measurement used in various laboratories in the EC. The following laboratories took part in the exercise: CEN-Mol (Belgium), CEA-Cadarache (France), CEA-Fontenay-aux-Roses (France), KfK-Karlsruhe (Federal Republic of Germany), ENEA-Bologna (Italy), and UKAEA-Winfrith (United Kingdom). The objective of the aerosol measurement workshop was to assess the applicability and reliability of specific aerosol measuring instruments. Measurements performed with equipment from the participating laboratories were evaluated using a standard procedure. This enabled an estimate of the accuracy of the experimental data to be provided for the verification of aerosol codes. Thus these results can be used as input for the physical modelling of aerosol behaviour, and the work reported here is a contribution to the definition of the radioactive source term for severe accidents in LMFBRs. The aerosol experts participating in the exercise agreed to concentrate on the techniques of measuring aerosol particle size distributions. The tests were performed at the FAUNA test facility using the aerosol loop. A sodium spray fire, which provides a continuous aerosol source of variable concentration, was produced under open-loop conditions in this facility. Although the primary objective of the workshop was to determine the particle size distributions of the aerosols, measurements of the sodium mass concentration were also made

  7. Reliability of Various Measurement Stations for Determining Plantar Fascia Thickness and Echogenicity

    Directory of Open Access Journals (Sweden)

    Adebisi Bisi-Balogun

    2016-04-01

    Full Text Available This study aimed to determine the relative and absolute reliability of ultrasound (US measurements of the thickness and echogenicity of the plantar fascia (PF at different measurement stations along its length using a standardized protocol. Twelve healthy subjects (24 feet were enrolled. The PF was imaged in the longitudinal plane. Subjects were assessed twice to evaluate the intra-rater reliability. A quantitative evaluation of the thickness and echogenicity of the plantar fascia was performed using Image J, a digital image analysis and viewer software. A sonography evaluation of the thickness and echogenicity of the PF showed a high relative reliability with an Intra class correlation coefficient of ≥0.88 at all measurement stations. However, the measurement stations for both the PF thickness and echogenicity which showed the highest intraclass correlation coefficient (ICCs did not have the highest absolute reliability. Compared to other measurement stations, measuring the PF thickness at 3 cm distal and the echogenicity at a region of interest 1 cm to 2 cm distal from its insertion at the medial calcaneal tubercle showed the highest absolute reliability with the least systematic bias and random error. Also, the reliability was higher using a mean of three measurements compared to one measurement. To reduce discrepancies in the interpretation of the thickness and echogenicity measurements of the PF, the absolute reliability of the different measurement stations should be considered in clinical practice and research rather than the relative reliability with the ICC.

  8. Reliability of Various Measurement Stations for Determining Plantar Fascia Thickness and Echogenicity.

    Science.gov (United States)

    Bisi-Balogun, Adebisi; Cassel, Michael; Mayer, Frank

    2016-04-13

    This study aimed to determine the relative and absolute reliability of ultrasound (US) measurements of the thickness and echogenicity of the plantar fascia (PF) at different measurement stations along its length using a standardized protocol. Twelve healthy subjects (24 feet) were enrolled. The PF was imaged in the longitudinal plane. Subjects were assessed twice to evaluate the intra-rater reliability. A quantitative evaluation of the thickness and echogenicity of the plantar fascia was performed using Image J, a digital image analysis and viewer software. A sonography evaluation of the thickness and echogenicity of the PF showed a high relative reliability with an Intra class correlation coefficient of ≥0.88 at all measurement stations. However, the measurement stations for both the PF thickness and echogenicity which showed the highest intraclass correlation coefficient (ICCs) did not have the highest absolute reliability. Compared to other measurement stations, measuring the PF thickness at 3 cm distal and the echogenicity at a region of interest 1 cm to 2 cm distal from its insertion at the medial calcaneal tubercle showed the highest absolute reliability with the least systematic bias and random error. Also, the reliability was higher using a mean of three measurements compared to one measurement. To reduce discrepancies in the interpretation of the thickness and echogenicity measurements of the PF, the absolute reliability of the different measurement stations should be considered in clinical practice and research rather than the relative reliability with the ICC.

  9. Application of modern reliability database techniques to military system data

    International Nuclear Information System (INIS)

    Bunea, Cornel; Mazzuchi, Thomas A.; Sarkani, Shahram; Chang, H.-C.

    2008-01-01

    This paper focuses on analysis techniques of modern reliability databases, with an application to military system data. The analysis of military system data base consists of the following steps: clean the data and perform operation on it in order to obtain good estimators; present simple plots of data; analyze the data with statistical and probabilistic methods. Each step is dealt with separately and the main results are presented. Competing risks theory is advocated as the mathematical support for the analysis. The general framework of competing risks theory is presented together with simple independent and dependent competing risks models available in literature. These models are used to identify the reliability and maintenance indicators required by the operating personnel. Model selection is based on graphical interpretation of plotted data

  10. Inter-rater reliability of shoulder measurements in middle-aged women.

    Science.gov (United States)

    De Groef, A; Van Kampen, M; Vervloesem, N; Clabau, E; Christiaens, M-R; Neven, P; Geraerts, I; Struyf, F; Devoogdt, N

    2017-06-01

    To investigate inter-rater reliability of a set of shoulder measurements including inclinometry [shoulder range of motion (ROM)], acromion-table distance and pectoralis minor muscle length (static scapular positioning), upward rotation with two inclinometers (scapular kinematics) and pain pressure thresholds (muscle tenderness) in middle-aged women. Observational study. Thirty symptom-free middle-aged women (first cohort) were measured by two raters. All measurements with an intraclass correlation coefficient (ICC) below 0.75 were retested after an additional training period in a second cohort of 30 symptom-free middle-aged women. Inter-rater reliability of all variables was measured with the ICC (95% confidence interval) and standard error of measurement (SEM). Acromion-table distance (ICC=0.91, SEM 0.22 to 0.28% of body length), pectoralis minor muscle length (ICC=0.91, SEM 0.16% of body length), pain pressure thresholds (ICC=0.78 to 0.85, SEM 0.39 to 0.70kg) and abduction ROM (ICC=0.77, SEM 5°) showed good to excellent inter-rater reliability in the first cohort. After an additional training period, forward flexion ROM showed good inter-rater reliability (ICC=0.83, SEM 5°), scapular upward rotation in resting position showed moderate reliability (ICC=0.52, SEM 2°), and other scaption angles showed weak reliability (ICC=0.26 to 0.43, SEM 3 to 8°). In a battery of clinical tools to evaluate factors contributing to shoulder pain, static scapular positioning and pressure pain thresholds were found to have good to excellent inter-rater reliability in middle-aged women. Additional training is recommended for measurements with a gravity inclinometer. Copyright © 2016 Chartered Society of Physiotherapy. Published by Elsevier Ltd. All rights reserved.

  11. Argonne National Laboratory's thermal plume measurements: instruments and techniques

    International Nuclear Information System (INIS)

    Van Loon, L.S.; Frigo, A.A.; Paddock, R.A.

    1977-12-01

    Instrumentation and techniques were developed at Argonne National Laboratory for measuring the three-dimensional temperature structure of thermal plumes from power plants, along with the limnological, meteorological, and plant operating conditions affecting their behavior. The equipment and procedures were designed to provide field data for use in evaluating predictive models that describe thermal plume behavior, and over 100 sets of these data have been collected. The instrument systems and techniques employed in a typical thermal discharge survey are highly integrated. Continuous monitoring of ambient and plant conditions is coupled with plume mapping from a moving survey boat. The instantaneous location of the boat together with subsurface temperature measurements from a towed thermistor chain provide a quasisynoptic view of the plume structure. Real-time, onboard display of the boat path and vertical temperatures supply feedback to investigators for determining the extent and spatial resolution of measurements required. The unique design, reliability, accuracy, calibration, and historical development of the components of these integrated systems are described. Survey system interfaces with data handling and processing techniques are also explained. Special supportive studies to investigate plume dynamics, values of eddy diffusivities, time-temperature histories of water parcels in thermal plumes, and rapid changes in plume shape are also described along with instrumentation used

  12. Reliability Evaluation Methodologies of Fault Tolerant Techniques of Digital I and C Systems in Nuclear Power Plants

    International Nuclear Information System (INIS)

    Kim, Bo Gyung; Kang, Hyun Gook; Seong, Poong Hyun; Lee, Seung Jun

    2011-01-01

    Since the reactor protection system was replaced from analog to digital, digital reactor protection system has 4 redundant channels and each channel has several modules. It is necessary for various fault tolerant techniques to improve availability and reliability due to using complex components in DPPS. To use the digital system, it is necessary to improve the reliability and availability of a system through fault-tolerant techniques. Several researches make an effort to effects of fault tolerant techniques. However, the effects of fault tolerant techniques have not been properly considered yet in most fault tree models. Various fault-tolerant techniques, which used in digital system in NPPs, should reflect in fault tree analysis for getting lower system unavailability and more reliable PSA. When fault-tolerant techniques are modeled in fault tree, categorizing the module to detect by each fault tolerant techniques, fault coverage, detection period and the fault recovery should be considered. Further work will concentrate on various aspects for fault tree modeling. We will find other important factors, and found a new theory to construct the fault tree model

  13. Intra- and interobserver reliability of quantitative ultrasound measurement of the plantar fascia.

    Science.gov (United States)

    Rathleff, Michael Skovdal; Moelgaard, Carsten; Lykkegaard Olesen, Jens

    2011-01-01

    To determine intra- and interobserver reliability and measurement precision of sonographic assessment of plantar fascia thickness when using one, the mean of two, or the mean of three measurements. Two experienced observers scanned 20 healthy subjects twice with 60 minutes between test and retest. A GE LOGIQe ultrasound scanner was used in the study. The built-in software in the scanner was used to measure the thickness of the plantar fascia (PF). Reliability was calculated using intraclass correlation coefficient (ICC) and limits of agreement (LOA). Intraobserver reliability (ICC) using one measurement was 0.50 for one observer and 0.52 for the other, and using the mean of three measurements intraobserver reliability increased up to 0.77 and 0.67, respectively. Interobserver reliability (ICC) when using one measurement was 0.62 and increased to 0.82 when using the average of three measurements. LOA showed that when using the average of three measurements, LOA decreased to 0.6 mm, corresponding to 17.5% of the mean thickness of the PF. The results showed that reliability increases when using the mean of three measurements compared with one. Limits of agreement based on intratester reliability shows that changes in thickness that are larger than 0.6 mm can be considered actual changes in thickness and not a result of measurement error. Copyright © 2011 Wiley Periodicals, Inc.

  14. Reliability of system identification techniques to assess standing balance in healthy elderly

    NARCIS (Netherlands)

    Pasma, Jantsje H.; Engelhart, Denise; Maier, Andrea B.; Aarts, Ronald G.K.M.; Van Gerven, Joop M.A.; Arendzen, J. Hans; Schouten, Alfred C.; Meskers, Carel G.M.; Van Kooij, Herman Der

    2016-01-01

    Objectives System identification techniques have the potential to assess the contribution of the underlying systems involved in standing balance by applying well-known disturbances. We investigated the reliability of standing balance parameters obtained with multivariate closed loop system

  15. Reliability of System Identification Techniques to Assess Standing Balance in Healthy Elderly

    NARCIS (Netherlands)

    Pasma, J.H.; Engelhart, D.; Maier, A.B.; Aarts, R.G.K.M.; Van Gerven, J.M.A.; Arendzen, J.H.; Schouten, A.C.; Meskers, C.G.M.; Van der Kooij, H.

    2016-01-01

    Objectives System identification techniques have the potential to assess the contribution of the underlying systems involved in standing balance by applying well-known disturbances. We investigated the reliability of standing balance parameters obtained with multivariate closed loop system

  16. Reliability of pelvic floor measurements on three- and four-dimensional ultrasound during and after first pregnancy: implications for training.

    Science.gov (United States)

    van Veelen, G A; Schweitzer, K J; van der Vaart, C H

    2013-11-01

    To evaluate the reliability of measurements of the levator hiatus and levator-urethra gap (LUG) using three/four-dimensional (3D/4D) transperineal ultrasound in women during their first pregnancy and 6 months postpartum, and to assess the learning process for these measurements. An inexperienced observer was taught to perform measurements of the levator hiatus and LUG by an experienced observer. After training, 3D/4D ultrasound volume datasets of 40 women in the first trimester were analyzed by these two observers. Another training session then took place and both observers repeated the analyses of the same volume datasets. Finally, analyses of 40 volume datasets of the women 6 months postpartum were performed by both observers. Intra- and interobserver reliability were determined by intraclass correlation coefficients (ICC) with 95% CIs. For levator hiatal measurements, in the women during their first pregnancy the interobserver reliability was substantial to almost perfect after both the first and second training session (ICC, 0.62-0.83 and 0.71-0.89, respectively, for anteroposterior diameter, transverse diameter and area at rest, on contraction and on Valsalva) and the intraobserver reliability was substantial to almost perfect for both observers. For these measurements performed once the women had delivered, interobserver reliability was moderate to almost perfect. For LUG measurements performed during pregnancy, interobserver reliability was slight to moderate after the first training session (ICC, 0.14-0.54), but improved after the second training session (ICC, 0.38-0.71), and intraobserver reliability was moderate to substantial for the experienced observer and slight to moderate for the inexperienced observer. For these measurements performed when the women had delivered, interobserver reliability was fair to moderate. The levator hiatus and LUG can be measured reliably using 3D/4D ultrasound in primigravid and primiparous women. The technique to measure

  17. Reliability of Wearable Inertial Measurement Units to Measure Physical Activity in Team Handball.

    Science.gov (United States)

    Luteberget, Live S; Holme, Benjamin R; Spencer, Matt

    2018-04-01

    To assess the reliability and sensitivity of commercially available inertial measurement units to measure physical activity in team handball. Twenty-two handball players were instrumented with 2 inertial measurement units (OptimEye S5; Catapult Sports, Melbourne, Australia) taped together. They participated in either a laboratory assessment (n = 10) consisting of 7 team handball-specific tasks or field assessment (n = 12) conducted in 12 training sessions. Variables, including PlayerLoad™ and inertial movement analysis (IMA) magnitude and counts, were extracted from the manufacturers' software. IMA counts were divided into intensity bands of low (1.5-2.5 m·s -1 ), medium (2.5-3.5 m·s -1 ), high (>3.5 m·s -1 ), medium/high (>2.5 m·s -1 ), and total (>1.5 m·s -1 ). Reliability between devices and sensitivity was established using coefficient of variation (CV) and smallest worthwhile difference (SWD). Laboratory assessment: IMA magnitude showed a good reliability (CV = 3.1%) in well-controlled tasks. CV increased (4.4-6.7%) in more-complex tasks. Field assessment: Total IMA counts (CV = 1.8% and SWD = 2.5%), PlayerLoad (CV = 0.9% and SWD = 2.1%), and their associated variables (CV = 0.4-1.7%) showed a good reliability, well below the SWD. However, the CV of IMA increased when categorized into intensity bands (2.9-5.6%). The reliability of IMA counts was good when data were displayed as total, high, or medium/high counts. A good reliability for PlayerLoad and associated variables was evident. The CV of the previously mentioned variables was well below the SWD, suggesting that OptimEye's inertial measurement unit and its software are sensitive for use in team handball.

  18. Reliability of reflectance measures in passive filters

    Science.gov (United States)

    Saldiva de André, Carmen Diva; Afonso de André, Paulo; Rocha, Francisco Marcelo; Saldiva, Paulo Hilário Nascimento; Carvalho de Oliveira, Regiani; Singer, Julio M.

    2014-08-01

    Measurements of optical reflectance in passive filters impregnated with a reactive chemical solution may be transformed to ozone concentrations via a calibration curve and constitute a low cost alternative for environmental monitoring, mainly to estimate human exposure. Given the possibility of errors caused by exposure bias, it is common to consider sets of m filters exposed during a certain period to estimate the latent reflectance on n different sample occasions at a certain location. Mixed models with sample occasions as random effects are useful to analyze data obtained under such setups. The intra-class correlation coefficient of the mean of the m measurements is an indicator of the reliability of the latent reflectance estimates. Our objective is to determine m in order to obtain a pre-specified reliability of the estimates, taking possible outliers into account. To illustrate the procedure, we consider an experiment conducted at the Laboratory of Experimental Air Pollution, University of São Paulo, Brazil (LPAE/FMUSP), where sets of m = 3 filters were exposed during 7 days on n = 9 different occasions at a certain location. The results show that the reliability of the latent reflectance estimates for each occasion obtained under homoskedasticity is km = 0.74. A residual analysis suggests that the within-occasion variance for two of the occasions should be different from the others. A refined model with two within-occasion variance components was considered, yielding km = 0.56 for these occasions and km = 0.87 for the remaining ones. To guarantee that all estimates have a reliability of at least 80% we require measurements on m = 10 filters on each occasion.

  19. Quantitative measurement of hypertrophic scar: interrater reliability and concurrent validity.

    Science.gov (United States)

    Nedelec, Bernadette; Correa, José A; Rachelska, Grazyna; Armour, Alexis; LaSalle, Léo

    2008-01-01

    Research into the pathophysiology and treatment of hypertrophic scar (HSc) remains limited by the heterogeneity of scar and the imprecision with which its severity is measured. The objective of this study was to test the interrater reliability and concurrent validity of the Cutometer measurement of elasticity, the Mexameter measurement of erythema and pigmentation, and total thickness measure of the DermaScan C relative to the modified Vancouver Scar Scale (mVSS) in patient-matched normal skin, normal scar, and HSc. Three independent investigators evaluated 128 sites (severe HSc, moderate or mild HSc, donor site, and normal skin) on 32 burn survivors using all of the above measurement tools. The intraclass correlation coefficient, which was used to measure interrater reliability, reflects the inherent amount of error in the measure and is considered acceptable when it is >0.75. Interrater reliability of the totals of the height, pliability, and vascularity subscales of the mVSS fell below the acceptable limit ( congruent with0.50). The individual subscales of the mVSS fell well below the acceptable level (0.89) for each study site with the exception of severe scar. Mexameter and DermaScan C reliability measurements were acceptable for all sites (>0.82). Concurrent validity correlations with the mVSS were significant except for the comparison of the mVSS pliability subscale and the Cutometer maximum deformation measure comparison in severe scar. In conclusion, the Mexameter and DermaScan C measurements of scar color and thickness of all sites, as well as the Cutometer measurement of elasticity in all but the most severe scars shows high interrater reliability. Their significant concurrent validity with the mVSS confirms that these tools are measuring the same traits as the mVSS, and in a more objective way.

  20. Ultrasonic Technique for Density Measurement of Liquids in Extreme Conditions

    Science.gov (United States)

    Kazys, Rymantas; Sliteris, Reimondas; Rekuviene, Regina; Zukauskas, Egidijus; Mazeika, Liudas

    2015-01-01

    An ultrasonic technique, invariant to temperature changes, for a density measurement of different liquids under in situ extreme conditions is presented. The influence of geometry and material parameters of the measurement system (transducer, waveguide, matching layer) on measurement accuracy and reliability is analyzed theoretically along with experimental results. The proposed method is based on measurement of the amplitude of the ultrasonic wave, reflected from the interface of the solid/liquid medium under investigation. In order to enhance sensitivity, the use of a quarter wavelength acoustic matching layer is proposed. Therefore, the sensitivity of the measurement system increases significantly. Density measurements quite often must be performed in extreme conditions at high temperature (up to 220 °C) and high pressure. In this case, metal waveguides between piezoelectric transducer and the measured liquid are used in order to protect the conventional transducer from the influence of high temperature and to avoid depolarization. The presented ultrasonic density measurement technique is suitable for density measurement in different materials, including liquids and polymer melts in extreme conditions. A new calibration algorithm was proposed. The metrological evaluation of the measurement method was performed. The expanded measurement uncertainty Uρ = 7.4 × 10−3 g/cm3 (1%). PMID:26262619

  1. Ultrasonic Technique for Density Measurement of Liquids in Extreme Conditions.

    Science.gov (United States)

    Kazys, Rymantas; Sliteris, Reimondas; Rekuviene, Regina; Zukauskas, Egidijus; Mazeika, Liudas

    2015-08-07

    An ultrasonic technique, invariant to temperature changes, for a density measurement of different liquids under in situ extreme conditions is presented. The influence of geometry and material parameters of the measurement system (transducer, waveguide, matching layer) on measurement accuracy and reliability is analyzed theoretically along with experimental results. The proposed method is based on measurement of the amplitude of the ultrasonic wave, reflected from the interface of the solid/liquid medium under investigation. In order to enhance sensitivity, the use of a quarter wavelength acoustic matching layer is proposed. Therefore, the sensitivity of the measurement system increases significantly. Density measurements quite often must be performed in extreme conditions at high temperature (up to 220 °C) and high pressure. In this case, metal waveguides between piezoelectric transducer and the measured liquid are used in order to protect the conventional transducer from the influence of high temperature and to avoid depolarization. The presented ultrasonic density measurement technique is suitable for density measurement in different materials, including liquids and polymer melts in extreme conditions. A new calibration algorithm was proposed. The metrological evaluation of the measurement method was performed. The expanded measurement uncertainty Uρ = 7.4 × 10(-3) g/cm(3) (1%).

  2. Ultrasonic Technique for Density Measurement of Liquids in Extreme Conditions

    Directory of Open Access Journals (Sweden)

    Rymantas Kazys

    2015-08-01

    Full Text Available An ultrasonic technique, invariant to temperature changes, for a density measurement of different liquids under in situ extreme conditions is presented. The influence of geometry and material parameters of the measurement system (transducer, waveguide, matching layer on measurement accuracy and reliability is analyzed theoretically along with experimental results. The proposed method is based on measurement of the amplitude of the ultrasonic wave, reflected from the interface of the solid/liquid medium under investigation. In order to enhance sensitivity, the use of a quarter wavelength acoustic matching layer is proposed. Therefore, the sensitivity of the measurement system increases significantly. Density measurements quite often must be performed in extreme conditions at high temperature (up to 220 °C and high pressure. In this case, metal waveguides between piezoelectric transducer and the measured liquid are used in order to protect the conventional transducer from the influence of high temperature and to avoid depolarization. The presented ultrasonic density measurement technique is suitable for density measurement in different materials, including liquids and polymer melts in extreme conditions. A new calibration algorithm was proposed. The metrological evaluation of the measurement method was performed. The expanded measurement uncertainty Uρ = 7.4 × 10−3 g/cm3 (1%.

  3. Techniques for developing reliable and functional materials control and accounting software

    International Nuclear Information System (INIS)

    Barlich, G.

    1988-01-01

    The media has increasingly focused on failures of computer systems resulting in financial, material, and other losses and on systems failing to function as advertised. Unfortunately, such failures with equally disturbing losses are possible in computer systems providing materials control and accounting (MCandA) functions. Major improvements in the reliability and correctness of systems are possible with disciplined design and development techniques applied during software development. This paper describes some of the techniques used in the Safeguard Systems Group at Los Alamos National Laboratory for various MCandA systems

  4. An In vitro evaluation of the reliability of QR code denture labeling technique.

    Science.gov (United States)

    Poovannan, Sindhu; Jain, Ashish R; Krishnan, Cakku Jalliah Venkata; Chandran, Chitraa R

    2016-01-01

    Positive identification of the dead after accidents and disasters through labeled dentures plays a key role in forensic scenario. A number of denture labeling methods are available, and studies evaluating their reliability under drastic conditions are vital. This study was conducted to evaluate the reliability of QR (Quick Response) Code labeled at various depths in heat-cured acrylic blocks after acid treatment, heat treatment (burns), and fracture in forensics. It was an in vitro study. This study included 160 specimens of heat-cured acrylic blocks (1.8 cm × 1.8 cm) and these were divided into 4 groups (40 samples per group). QR Codes were incorporated in the samples using clear acrylic sheet and they were assessed for reliability under various depths, acid, heat, and fracture. Data were analyzed using Chi-square test, test of proportion. The QR Code inclusion technique was reliable under various depths of acrylic sheet, acid (sulfuric acid 99%, hydrochloric acid 40%) and heat (up to 370°C). Results were variable with fracture of QR Code labeled acrylic blocks. Within the limitations of the study, by analyzing the results, it was clearly indicated that the QR Code technique was reliable under various depths of acrylic sheet, acid, and heat (370°C). Effectiveness varied in fracture and depended on the level of distortion. This study thus suggests that QR Code is an effective and simpler denture labeling method.

  5. Interactive reliability assessment using an integrated reliability data bank

    International Nuclear Information System (INIS)

    Allan, R.N.; Whitehead, A.M.

    1986-01-01

    The logical structure, techniques and practical application of a computer-aided technique based on a microcomputer using floppy disc Random Access Files is described. This interactive computational technique is efficient if the reliability prediction program is coupled directly to a relevant source of data to create an integrated reliability assessment/reliability data bank system. (DG)

  6. The transverse technique; a complementary approach to the measurement of first-trimester uterine artery Doppler.

    Science.gov (United States)

    Drouin, Olivier; Johnson, Jo-Ann; Chaemsaithong, Piya; Metcalfe, Amy; Huber, Janie; Schwarzenberger, Jill; Winters, Erin; Stavness, Lesley; Tse, Ada W T; Lu, Jing; Lim, Wan Teng; Leung, Tak Yeung; Bujold, Emmanuel; Sahota, Daljit; Poon, Liona C

    2017-10-04

    The objectives of this study were to 1) define the protocol for the first-trimester assessment of the uterine artery pulsatility index (UtA-PI) using the new transverse technique, 2) evaluate UtA-PI measured by the transverse approach versus that obtained by the conventional sagittal approach, and 3) determine if accelerated onsite training (both methods) of inexperienced sonographers can achieve reproducible UtA-PI measurements compared to that measured by an experienced sonographer. The study consists of 2 parts conducted in 2 centers (Part 1, Calgary, Canada and Part 2, Hong Kong). Part 1 Prospective observational study of women with singleton pregnancies between 11-13+6 weeks' gestation. UtA-PI measurements were performed using the 2 techniques (4 sonographers trained in both methods, 10 cases each) and measurement indices (PI), time required and subjective difficulty to obtain satisfactory measurements were compared. One sample t-test and Wilcoxon rank sign test was used when appropriate. Bland-Altman difference plots were used to assess measurement agreement, and intra-class correlation (ICC) was used to evaluate measurement reliability. A target plot was used to assess measures of central tendency and dispersion. Part 2 One experienced and three inexperienced sonographers prospectively measured the UtA-PI at 11-13+6 weeks' gestation in two groups of women (42 and 35, respectively), with singleton pregnancies using both approaches. Inexperienced sonographers underwent accelerated on-site training by the experienced sonographer. Measurement approach and sonographer order were on a random basis. ICC, Bland-Altman and Passing-Bablok analyses were performed to assess measurement agreement, reliability and effect of accelerated training. Part 1 We observed no difference in the mean time to acquire the measurements (Sagittal: 118 seconds vs Transverse: 106 seconds, p=0.38). The 4 sonographers reported the transverse technique was subjectively easier to perform (p=0

  7. Measuring Passenger Travel Time Reliability Using Smart Card Data

    NARCIS (Netherlands)

    Bagherian, M.; Cats, O.; van Oort, N.; Hickman, M

    2016-01-01

    Service reliability is a key performance measure for transit agencies in increasing their service quality and thus ridership. Conventional reliability metrics are established based on vehicle movements and thus do not adequately reflect passenger’s experience. In the past few years, the growing

  8. Measuring time and risk preferences: Reliability, stability, domain specificity

    NARCIS (Netherlands)

    Wölbert, E.M.; Riedl, A.M.

    2013-01-01

    To accurately predict behavior economists need reliable measures of individual time preferences and attitudes toward risk and typically need to assume stability of these characteristics over time and across decision domains. We test the reliability of two choice tasks for eliciting discount rates,

  9. Cost-effective ERT technique for oil-in-water measurement for offshore hydrocyclone installations

    DEFF Research Database (Denmark)

    Durdevic, Petar; Hansen, Leif; Mai, Christian

    2015-01-01

    The goal of this paper is to introduce and design a cost-effective Oil-in-Water (OiW) measuring instrument, which will be investigated for its value in increasing the efficiency of a deoiling hydrocyclone. The technique investigated is based on Electrical Resistivity Tomography (ERT), which basic...... principle is to measure the resistivity of substances from multiple electrodes and from these measurements create a 2-D image of the oil and gas component in the water. This technique requires the measured components to have different electrical resistances, such as seawater which has a lower electrical...... resistance than hydrocarbon oil and gas. This work involves construction of a pilot plant, for testing the feasibility of ERT for OiW measurements, and further exploring if this measured signal can be applied as a reliable feedback signal in optimization of the hydrocyclone's efficiency. Different algorithms...

  10. Cost-Effective ERT Technique for Oil-in-Water Measurement for Offshore Hydrocyclone Installations

    DEFF Research Database (Denmark)

    Løhndorf, Petar Durdevic; Hansen, Leif; Mai, Christian

    2015-01-01

    The goal of this paper is to introduce and design a cost-effective Oil-in-Water (OiW) measuring instrument, which will be investigated for its value in increasing the efficiency of a deoiling hydrocyclone. The technique investigated is based on Electrical Resistivity Tomography (ERT), which basic...... principle is to measure the resistivity of substances from multiple electrodes and from these measurements create a 2-D image of the oil and gas component in the water. This technique requires the measured components to have different electrical resistances, such as seawater which has a lower electrical...... resistance than hydrocarbon oil and gas. This work involves construction of a pilot plant, for testing the feasibility of ERT for OiW measurements, and further exploring if this measured signal can be applied as a reliable feedback signal in optimization of the hydrocyclone's efficiency. Different algorithms...

  11. EDITORIAL: Measurement techniques for multiphase flows Measurement techniques for multiphase flows

    Science.gov (United States)

    Okamoto, Koji; Murai, Yuichi

    2009-11-01

    Research on multiphase flows is very important for industrial applications, including power stations, vehicles, engines, food processing and so on. Multiphase flows originally have nonlinear features because of multiphase systems. The interaction between the phases plays a very interesting role in the flows. The nonlinear interaction causes the multiphase flows to be very complicated. Therefore techniques for measuring multiphase flows are very useful in helping to understand the nonlinear phenomena. The state-of-the-art measurement techniques were presented and discussed at the sixth International Symposium on Measurement Techniques for Multiphase Flows (ISMTMF2008) held in Okinawa, Japan, on 15-17 December 2008. This special feature of Measurement Science and Technology includes selected papers from ISMTMF2008. Okinawa has a long history as the Ryukyus Kingdom. China, Japan and many western Pacific countries have had cultural and economic exchanges through Okinawa for over 1000 years. Much technical and scientific information was exchanged at the symposium in Okinawa. The proceedings of ISMTMF2008 apart from these special featured papers were published in Journal of Physics: Conference Series vol. 147 (2009). We would like to express special thanks to all the contributors to the symposium and this special feature. This special feature will be a milestone in measurement techniques for multiphase flows.

  12. Automated reliability assessment for spectroscopic redshift measurements

    Science.gov (United States)

    Jamal, S.; Le Brun, V.; Le Fèvre, O.; Vibert, D.; Schmitt, A.; Surace, C.; Copin, Y.; Garilli, B.; Moresco, M.; Pozzetti, L.

    2018-03-01

    Context. Future large-scale surveys, such as the ESA Euclid mission, will produce a large set of galaxy redshifts (≥106) that will require fully automated data-processing pipelines to analyze the data, extract crucial information and ensure that all requirements are met. A fundamental element in these pipelines is to associate to each galaxy redshift measurement a quality, or reliability, estimate. Aim. In this work, we introduce a new approach to automate the spectroscopic redshift reliability assessment based on machine learning (ML) and characteristics of the redshift probability density function. Methods: We propose to rephrase the spectroscopic redshift estimation into a Bayesian framework, in order to incorporate all sources of information and uncertainties related to the redshift estimation process and produce a redshift posterior probability density function (PDF). To automate the assessment of a reliability flag, we exploit key features in the redshift posterior PDF and machine learning algorithms. Results: As a working example, public data from the VIMOS VLT Deep Survey is exploited to present and test this new methodology. We first tried to reproduce the existing reliability flags using supervised classification in order to describe different types of redshift PDFs, but due to the subjective definition of these flags (classification accuracy 58%), we soon opted for a new homogeneous partitioning of the data into distinct clusters via unsupervised classification. After assessing the accuracy of the new clusters via resubstitution and test predictions (classification accuracy 98%), we projected unlabeled data from preliminary mock simulations for the Euclid space mission into this mapping to predict their redshift reliability labels. Conclusions: Through the development of a methodology in which a system can build its own experience to assess the quality of a parameter, we are able to set a preliminary basis of an automated reliability assessment for

  13. Applying of Reliability Techniques and Expert Systems in Management of Radioactive Accidents

    International Nuclear Information System (INIS)

    Aldaihan, S.; Alhbaib, A.; Alrushudi, S.; Karazaitri, C.

    1998-01-01

    Accidents including radioactive exposure have variety of nature and size. This makes such accidents complex situations to be handled by radiation protection agencies or any responsible authority. The situations becomes worse with introducing advanced technology with high complexity that provide operator huge information about system working on. This paper discusses the application of reliability techniques in radioactive risk management. Event tree technique from nuclear field is described as well as two other techniques from nonnuclear fields, Hazard and Operability and Quality Function Deployment. The objective is to show the importance and the applicability of these techniques in radiation risk management. Finally, Expert Systems in the field of accidents management are explored and classified upon their applications

  14. Stress Rupture Life Reliability Measures for Composite Overwrapped Pressure Vessels

    Science.gov (United States)

    Murthy, Pappu L. N.; Thesken, John C.; Phoenix, S. Leigh; Grimes-Ledesma, Lorie

    2007-01-01

    Composite Overwrapped Pressure Vessels (COPVs) are often used for storing pressurant gases onboard spacecraft. Kevlar (DuPont), glass, carbon and other more recent fibers have all been used as overwraps. Due to the fact that overwraps are subjected to sustained loads for an extended period during a mission, stress rupture failure is a major concern. It is therefore important to ascertain the reliability of these vessels by analysis, since the testing of each flight design cannot be completed on a practical time scale. The present paper examines specifically a Weibull statistics based stress rupture model and considers the various uncertainties associated with the model parameters. The paper also examines several reliability estimate measures that would be of use for the purpose of recertification and for qualifying flight worthiness of these vessels. Specifically, deterministic values for a point estimate, mean estimate and 90/95 percent confidence estimates of the reliability are all examined for a typical flight quality vessel under constant stress. The mean and the 90/95 percent confidence estimates are computed using Monte-Carlo simulation techniques by assuming distribution statistics of model parameters based also on simulation and on the available data, especially the sample sizes represented in the data. The data for the stress rupture model are obtained from the Lawrence Livermore National Laboratories (LLNL) stress rupture testing program, carried out for the past 35 years. Deterministic as well as probabilistic sensitivities are examined.

  15. Certification of temperature measuring techniques at thermal and nuclear power plants

    International Nuclear Information System (INIS)

    Preobrazhenskij, V.P.; Strigina, L.A.

    1980-01-01

    Necessity for metrological certification of temperature measurement techniques (TMT) at thermal and nuclear energy plants is grounded. An order of TMT certification is stated and formulae for determining the accuracy of temperature measurements by the thermoelectric method are given. It is concluded that through there are also statistical characteristics of errors of a number of measurement properties, it is necessary to carry on statistical investigations into errors of thermoelectrode extending wires, planimeters, measurement conditions. Such kind investigation technigues have been developed. Besides, it is necessary to regulate a uniform approach to the usage of statistical characteristics of errors of means and conditions of measurements to minimize volume of work for the personnel of thermal and nuclear energy plants and provide reliable estimates of temperature measurement errors

  16. Reliability of Ultrasonographic Measurement of Cervical Multifidus Muscle Dimensions during Isometric Contraction of Neck Muscles

    Directory of Open Access Journals (Sweden)

    Somayeh Amiri Arimi

    2012-07-01

    Full Text Available Background and Aim: Cervical multifidus is considered as one of the most important neck stabilizers. Weakness and muscular atrophy of this muscle were seen in patients with chronic neck pain. Ultrasonographic imaging is a non-invasive and feasible technique that commonly used to record such changes and measure muscle dimensions. Therefore, the aim of this study was to evaluate the reliability of ultrasonographic measurement of cervical multifidus muscle’s dimensions during isometric contraction of neck muscles. Materials and Method: Ten subjects (5 patients with chronic neck pain and 5 healthy subjects were recruited in this study. Cervical multifidus muscle’s dimensions were measured at the level of forth cervical vertebrae. Ultrasonographic measurement of cervical multifidus muscle at rest, 50% and 100% of maximal voluntary contraction (MVC were performed by one examiner within 1 week interval. The dimensions of cervical multifidus muscle including cross-sectional area (CSA, anterior posterior dimension (APD, and lateral dimension (LD were measured. Intraclass correlation coefficients (ICC, standard error of measurement (SEM and minimal detectable change (MDC were computed for data analysis.Results: The between days reliability of maximum strength of neck muscles and multifidus muscle dimensions at rest, 50% and 100% of MVC of neck muscles were good to excellent (ICC=0.75-0.99.Conclusion: The results of this study showed that ultrasonographic measuring of cervical multifidus muscle’s dimensions during isometric contraction of neck muscles at the level of C4 in females with chronic neck pain and healthy subjects is a reliable and repeatable method.

  17. Reliability techniques and Coupled BEM/FEM for interaction pile-soil

    Directory of Open Access Journals (Sweden)

    Ahmed SAHLI

    2017-06-01

    Full Text Available This paper deals with the development of a computational code for the modelling and verification of safety in relation to limit states of piles found in foundations of current structures. To this end, it makes use of reliability techniques for the probabilistic analysis of piles modelled with the finite element method (FEM coupled to the boundary element method (BEM. The soil is modelled with the BEM employing Mindlin's fundamental solutions, suitable for the consideration of a three-dimensional infinite half-space. The piles are modelled as bar elements with the MEF, each of which is represented in the BEM as a loading line. The finite element of the employed bar has four nodes and fourteen nodal parameters, three of which are displacements for each node plus two rotations for the top node. The slipping of the piles in relation to the mass is carried out using adhesion models to define the evolution of the shaft tensions during the transfer of load to the soil. The reliability analysis is based on three methods: first order second moment (FOSM, first order reliability method and Monte Carlo method.

  18. The attribute measurement technique

    International Nuclear Information System (INIS)

    MacArthur, Duncan W.; Langner, Diana; Smith, Morag; Thron, Jonathan; Razinkov, Sergey; Livke, Alexander

    2010-01-01

    Any verification measurement performed on potentially classified nuclear material must satisfy two seemingly contradictory constraints. First and foremost, no classified information can be released. At the same time, the monitoring party must have confidence in the veracity of the measurement. An information barrier (IB) is included in the measurement system to protect the potentially classified information while allowing sufficient information transfer to occur for the monitoring party to gain confidence that the material being measured is consistent with the host's declarations, concerning that material. The attribute measurement technique incorporates an IB and addresses both concerns by measuring several attributes of the nuclear material and displaying unclassified results through green (indicating that the material does possess the specified attribute) and red (indicating that the material does not possess the specified attribute) lights. The attribute measurement technique has been implemented in the AVNG, an attribute measuring system described in other presentations at this conference. In this presentation, we will discuss four techniques used in the AVNG: (1) the 1B, (2) the attribute measurement technique, (3) the use of open and secure modes to increase confidence in the displayed results, and (4) the joint design as a method for addressing both host and monitor needs.

  19. Reliability of EEG Interactions Differs between Measures and Is Specific for Neurological Diseases

    Directory of Open Access Journals (Sweden)

    Yvonne Höller

    2017-07-01

    Full Text Available Alterations of interaction (connectivity of the EEG reflect pathological processes in patients with neurologic disorders. Nevertheless, it is questionable whether these patterns are reliable over time in different measures of interaction and whether this reliability of the measures is the same across different patient populations. In order to address this topic we examined 22 patients with mild cognitive impairment, five patients with subjective cognitive complaints, six patients with right-lateralized temporal lobe epilepsy, seven patients with left lateralized temporal lobe epilepsy, and 20 healthy controls. We calculated 14 measures of interaction from two EEG-recordings separated by 2 weeks. In order to characterize test-retest reliability, we correlated these measures for each group and compared the correlations between measures and between groups. We found that both measures of interaction as well as groups differed from each other in terms of reliability. The strongest correlation coefficients were found for spectrum, coherence, and full frequency directed transfer function (average rho > 0.9. In the delta (2–4 Hz range, reliability was lower for mild cognitive impairment compared to healthy controls and left lateralized temporal lobe epilepsy. In the beta (13–30 Hz, gamma (31–80 Hz, and high gamma (81–125 Hz frequency ranges we found decreased reliability in subjective cognitive complaints compared to mild cognitive impairment. In the gamma and high gamma range we found increased reliability in left lateralized temporal lobe epilepsy patients compared to healthy controls. Our results emphasize the importance of documenting reliability of measures of interaction, which may vary considerably between measures, but also between patient populations. We suggest that studies claiming clinical usefulness of measures of interaction should provide information on the reliability of the results. In addition, differences between patient

  20. Confiabilidade de medidas volumétricas de estruturas temporais mesiais Reliability of mesial temporal lobe volumetric measures

    Directory of Open Access Journals (Sweden)

    Renato L. Marchetti

    2002-06-01

    Full Text Available MOTIVO DO ESTUDO: O desenvolvimento de técnicas confiáveis para a realização de medidas volumétricas de estruturas temporais mesiais (amígdala, hipocampo e giro para-hipocampal em exames de ressonância magnética (RM pode fornecer dados para o estudo de vários transtornos neuropsiquiátricos, particularmente epilepsia do lobo temporal, doença de Alzheimer e esquizofrenia. MÉTODO: Investigamos essas técnicas realizando estudo de confiabilidade intra-observador (IO e entre-observador (EO, envolvendo controles normais, pacientes com epilepsia e pacientes com doença de Alzheimer, através do coeficiente de correlação intra-classe (CCI. RESULTADOS: A confiabilidade IO para as estruturas analisadas variou de 0,93 a 0,99 (pRATIONALE: The development of reliable techniques for volumetric measurement of mesial temporal structures (amygdala, hypocampus and parahypocampal gyrus on magnetic resonance imaging (MRI can provide data for the study of neuropsychiatric disorders, mainly temporal lobe epilepsy, Alzheimer´s disease and schizophrenia. METHOD: We investigated these techniques performing intraobserver and interobserver reliability study concerning normal controls, epilepsy and Alzheimer's disease patients using the intra-class correlation coefficient. RESULTS: Intra-observer reliability of evaluated structures ranged from 0.93 to 0.99 (p<0.001. Inter-observer reliability ranged from 0.70 to 0.95 (p <= 0.001. CONCLUSION: The results suggest that the technique of MRI morphometry of mesial temporal regions can be considered a reliable tool which may help in the investigation of neuropsychiatric disorders, since used by adequately trained clinicians and researchers.

  1. Reliability and relationship of radiographic measurements in hallux valgus.

    Science.gov (United States)

    Lee, Kyoung Min; Ahn, Soyeon; Chung, Chin Youb; Sung, Ki Hyuk; Park, Moon Seok

    2012-09-01

    Although various radiographic measurements have been developed and used for evaluating hallux valgus, not all are universally believed to be necessary and their relationships have not been clearly established. Determining which are related could provide some insight into which might be useful and which would not. We investigated the reliability of eight radiographic measurements used to evaluate hallux valgus, and determined which were correlated and which predicted the hallux valgus angle. We determined eight radiographic indices for 732 patients (mean age, 51 years; SD, 17 years; 107 males and 625 females) with hallux valgus: hallux valgus angle, intermetatarsal angle, hallux interphalangeal angle, distal metatarsal articular angle, proximal phalangeal articular angle, simplified metatarsus adductus angle, first metatarsal protrusion distance, and sesamoid rotation angle. Intraobserver and interobserver reliabilities of each radiographic measurement were analyzed on 36 feet from 36 randomly selected patients. Correlations among the radiographic measurements were analyzed. Radiographic measurements predicting hallux valgus angle were evaluated using multiple regression analysis. Hallux valgus angle had the highest reliability, whereas the distal metatarsal articular angle and simplified metatarsus adductus angle had the lowest. Distal metatarsal articular angle, intermetatarsal angle, and sesamoid rotation angle had the highest correlations with hallux valgus angle. Distal metatarsal articular angle correlated with sesamoid rotation angle. The intermetatarsal angle, interphalangeal angle, distal metatarsal articular angle, first metatarsal protrusion distance, sesamoid rotation angle, and metatarsus adductus angle predicted the hallux valgus angle. We suggest using hallux valgus angle, intermetatarsal angle, interphalangeal angle, sesamoid rotation angle, and first metatarsal protrusion distance considering their reliability and prediction of the deformity.

  2. Radiographic measurement reliability of lumbar lordosis in ankylosing spondylitis.

    Science.gov (United States)

    Lee, Jung Sub; Goh, Tae Sik; Park, Shi Hwan; Lee, Hong Seok; Suh, Kuen Tak

    2013-04-01

    Intraobserver and interobserver reliabilities of the several different methods to measure lumbar lordosis have been reported. However, it has not been studied sofar in patients with ankylosing spondylitis (AS). We evaluated the inter and intraobserver reliabilities of six specific measures of global lumbar lordosis in patients with AS. Ninety-one consecutive patients with AS who met the most recently modified New York criteria were enrolled and underwent anteroposterior and lateral radiographs of whole spine. The radiographs were divided into non-ankylosis (no bony bridge in the lumbar spine), incomplete ankylosis (lumbar spines were partially connected by bony bridge) and complete ankylosis groups to evaluate the reliability of the Cobb L1-S1, Cobb L1-L5, centroid, posterior tangent L1-S1, posterior tangent L1-L5, and TRALL methods. The radiographs were composed of 39 non-ankylosis, 27 incomplete ankylosis and 25 complete ankylosis. Intra- and inter-class correlation coefficients (ICCs) of all six methods were generally high. The ICCs were all ≥0.77 (excellent) for the six radiographic methods in the combined group. However, a comparison of the ICCs, 95 % confidence intervals and mean absolute difference (MAD) between groups with varying degrees of ankylosis showed that the reliability of the lordosis measurements decreased in proportion to the severity of ankylosis. The Cobb L1-S1, Cobb L1-L5 and posterior tangent L1-S1 method demonstrated higher ICCs for both inter and intraobserver comparisons and the other methods showed lower ICCs in all groups. The intraobserver MAD was similar in the Cobb L1-S1 and Cobb L1-L5 (2.7°-4.3°), but the other methods showed higher intraobserver MAD. Interobserver MAD of Cobb L1-L5 only showed low in all group. These results are the first to provide a reliability analysis of different global lumbar lordosis measurement methods in AS. The findings in this study demonstrated that the Cobb L1-L5 method is reliable for measuring

  3. RELIABILITY OF ANKLE-FOOT MORPHOLOGY, MOBILITY, STRENGTH, AND MOTOR PERFORMANCE MEASURES.

    Science.gov (United States)

    Fraser, John J; Koldenhoven, Rachel M; Saliba, Susan A; Hertel, Jay

    2017-12-01

    Assessment of foot posture, morphology, intersegmental mobility, strength and motor control of the ankle-foot complex are commonly used clinically, but measurement properties of many assessments are unclear. To determine test-retest and inter-rater reliability, standard error of measurement, and minimal detectable change of morphology, joint excursion and play, strength, and motor control of the ankle-foot complex. Reliability study. 24 healthy, recreationally-active young adults without history of ankle-foot injury were assessed by two clinicians on two occasions, three to ten days apart. Measurement properties were assessed for foot morphology (foot posture index, total and truncated length, width, arch height), joint excursion (weight-bearing dorsiflexion, rearfoot and hallux goniometry, forefoot inclinometry, 1 st metatarsal displacement) and joint play, strength (handheld dynamometry), and motor control rating during intrinsic foot muscle (IFM) exercises. Clinician order was randomized using a Latin Square. The clinicians performed independent examinations and did not confer on the findings for the duration of the study. Test-retest and inter-tester reliability and agreement was assessed using intraclass correlation coefficients (ICC 2,k ) and weighted kappa ( K w ). Test-retest reliability ICC were as follows: morphology: .80-1.00, joint excursion: .58-.97, joint play: -.67-.84, strength: .67-.92, IFM motor rating: K W -.01-.71. Inter-rater reliability ICC were as follows: morphology: .81-1.00, joint excursion: .32-.97, joint play: -1.06-1.00, strength: .53-.90, and IFM motor rating: K w .02-.56. Measures of ankle-foot posture, morphology, joint excursion, and strength demonstrated fair to excellent test-retest and inter-rater reliability. Test-retest reliability for rating of perceived difficulty and motor performance was good to excellent for short-foot, toe-spread-out, and hallux exercises and poor to fair for lesser toe extension. Joint play measures had

  4. Measuring reliability under epistemic uncertainty: Review on non-probabilistic reliability metrics

    Directory of Open Access Journals (Sweden)

    Kang Rui

    2016-06-01

    Full Text Available In this paper, a systematic review of non-probabilistic reliability metrics is conducted to assist the selection of appropriate reliability metrics to model the influence of epistemic uncertainty. Five frequently used non-probabilistic reliability metrics are critically reviewed, i.e., evidence-theory-based reliability metrics, interval-analysis-based reliability metrics, fuzzy-interval-analysis-based reliability metrics, possibility-theory-based reliability metrics (posbist reliability and uncertainty-theory-based reliability metrics (belief reliability. It is pointed out that a qualified reliability metric that is able to consider the effect of epistemic uncertainty needs to (1 compensate the conservatism in the estimations of the component-level reliability metrics caused by epistemic uncertainty, and (2 satisfy the duality axiom, otherwise it might lead to paradoxical and confusing results in engineering applications. The five commonly used non-probabilistic reliability metrics are compared in terms of these two properties, and the comparison can serve as a basis for the selection of the appropriate reliability metrics.

  5. Improved structural integrity through advances in reliable residual stress measurement: the impact of ENGIN-X

    Science.gov (United States)

    Edwards, L.; Santisteban, J. R.

    The determination of accurate reliable residual stresses is critical to many fields of structural integrity. Neutron stress measurement is a non-destructive technique that uniquely provides insights into stress fields deep within engineering components and structures. As such, it has become an increasingly important tool within engineering, leading to improved manufacturing processes to reduce stress and distortion as well as to the definition of more precise lifing procedures. This paper describes the likely impact of the next generation of dedicated engineering stress diffractometers currently being constructed and the utility of the technique using examples of residual stresses both beneficial and detrimental to structural integrity.

  6. Korean round-robin result for new international program to assess the reliability of emerging nondestructive techniques

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Kyung Cho; Kim, Jin Gyum; Kang, Sung Sik; Jhung, Myung Jo [Korea Institute of Nuclear Safety, Daejeon (Korea, Republic of)

    2017-04-15

    The Korea Institute of Nuclear Safety, as a representative organization of Korea, in February 2012 participated in an international Program to Assess the Reliability of Emerging Nondestructive Techniques initiated by the U.S. Nuclear Regulatory Commission. The goal of the Program to Assess the Reliability of Emerging Nondestructive Techniques is to investigate the performance of emerging and prospective novel nondestructive techniques to find flaws in nickel-alloy welds and base materials. In this article, Korean round-robin test results were evaluated with respect to the test blocks and various nondestructive examination techniques. The test blocks were prepared to simulate large-bore dissimilar metal welds, small-bore dissimilar metal welds, and bottom-mounted instrumentation penetration welds in nuclear power plants. Also, lessons learned from the Korean round-robin test were summarized and discussed.

  7. Approximate multi-state reliability expressions using a new machine learning technique

    International Nuclear Information System (INIS)

    Rocco S, Claudio M.; Muselli, Marco

    2005-01-01

    The machine-learning-based methodology, previously proposed by the authors for approximating binary reliability expressions, is now extended to develop a new algorithm, based on the procedure of Hamming Clustering, which is capable to deal with multi-state systems and any success criterion. The proposed technique is presented in details and verified on literature cases: experiment results show that the new algorithm yields excellent predictions

  8. Inter-Rater Reliability of Cyclotorsion Measurements Using Fundus Photography.

    Science.gov (United States)

    Dysli, Muriel; Kanku, Madeleine; Traber, Ghislaine L

    2018-04-01

    The foveo-papillary angle (FPA) on fundus photographs is the accepted standard for the measurement of ocular cyclotorsion. We assessed the inter-rater reliability of this method in healthy subjects and in patients with trochlear nerve palsies. In this methodological study, fundus photographs of healthy subjects and of patients with trochlear nerve palsies were made with a fundus camera (Zeiss Fundus Camera FF 450 plus, Jena, Germany). Three independent observers measured the FPA on the fundus photographs of all subjects in synedra View (synedra View 16, Version 16.0.0.11, Innsbruck, Austria). One hundred and four eyes of 52 subjects (26 healthy controls and 26 patients) were assessed. The mean FPA of the healthy controls was 5.80 degrees (°) [± 0.44 standard error of the mean (SEM)] compared to 11.55° (± 0.80 SEM) for patients with trochlear nerve palsies. The inter-rater reliability of all measured FPAs showed an intraclass correlation coefficient (ICC) of 0.98 (95% CI 0.97 - 0.98). The inter-rater reliability of objective cyclotorsion measurements using fundus photographs was very high. Georg Thieme Verlag KG Stuttgart · New York.

  9. Reliability of radiographic measurements for acute distal radius fractures

    International Nuclear Information System (INIS)

    Watson, Narelle J.; Asadollahi, Saeed; Parrish, Frank; Ridgway, Jacqueline; Tran, Phong; Keating, Jennifer L.

    2016-01-01

    The management of distal radial fractures is guided by the interpretation of radiographic findings. The aim of this investigation was to determine the intra- and inter-observer reliability of eight traditionally reported anatomic radiographic parameters in adults with an acute distal radius fracture. Five observers participated. All were routinely involved in making treatment decisions based on distal radius fracture radiographs. Observers performed independent repeated measurements on 30 radiographs for eight anatomical parameters: dorsal shift (mm), intra-articular gap (mm), intra-articular step (mm), palmar tilt (degrees), radial angle (degrees), radial height (mm), radial shift (mm), ulnar variance (mm). Intraclass correlation coefficients (ICCs) and the magnitude of retest errors were calculated. Measurement reliability was summarised as high (ICC > 0.80), moderate (0.60–0.80) or low (<0.60). Intra-observer reliability was high for dorsal shift and palmar tilt; moderate for radial angle, radial height, ulnar variance and radial shift; and low for intra-articular gap and step. Inter-observer reliability was high for palmar tilt; moderate for dorsal shift, ulnar variance, radial angle and radial height; and low for radial shift, intra-articular gap and step. Error magnitude (95 % confidence interval) was within 1–2 mm for intra-articular gap and step, 2–4 mm for ulnar variance, 4–6 mm for radial shift, dorsal shift and radial height, and 6–8° for radial angle and palmar tilt. Based on previous reports of critical values for palmar tilt, ulnar variance and radial angle, error margins appear small enough for measurements to be useful in guiding treatment decisions. Our findings indicate that clinicians cannot reliably measure values ≤1 mm for intra-articular gap and step when interpreting radiographic parameters using the standardised methods investigated in this study. As a guide for treatment selection, palmar tilt, ulnar variance and radial angle

  10. Optimizing the design and operation of reactor emergency systems using reliability analysis techniques

    International Nuclear Information System (INIS)

    Snaith, E.R.

    1975-01-01

    Following a reactor trip various reactor emergency systems, e.g. essential power supplies, emergency core cooling and boiler feed water arrangements are required to operate with a high degree of reliability. These systems must therefore be critically assessed to confirm their capability of operation and determine their reliability of performance. The use of probability analysis techniques enables the potential operating reliability of the systems to be calculated and this can then be compared with the overall reliability requirements. However, a system reliability analysis does much more than calculate an overall reliability value for the system. It establishes the reliability of all parts of the system and thus identifies the most sensitive areas of unreliability. This indicates the areas where any required improvements should be made and enables the overall systems' designs and modes of operation to be optimized, to meet the system and hence the overall reactor safety criteria. This paper gives specific examples of sensitive areas of unreliability that were identified as a result of a reliability analysis that was carried out on a reactor emergency core cooling system. Details are given of modifications to design and operation that were implemented with a resulting improvement in reliability of various reactor sub-systems. The report concludes that an initial calculation of system reliability should represent only the beginning of continuing process of system assessment. Data on equipment and system performance, particularly in those areas shown to be sensitive in their effect on the overall nuclear power plant reliability, should be collected and processed to give reliability data. These data should then be applied in further probabilistic analyses and the results correlated with the original analysis. This will demonstrate whether the required and the originally predicted system reliability is likely to be achieved, in the light of the actual history to date of

  11. Advanced in-flight measurement techniques

    CERN Document Server

    Lawson, Nicholas; Jentink, Henk; Kompenhans, Jürgen

    2013-01-01

    The book presents a synopsis of the main results achieved during the 3 year EU-project "Advanced Inflight Measurement Techniques (AIM)" which applied advanced image based measurement techniques to industrial flight testing. The book is intended to be not only an overview on the AIM activities but also a guide on the application of advanced optical measurement techniques for future flight testing. Furthermore it is a useful guide for engineers in the field of experimental methods and flight testing who face the challenge of a future requirement for the development of highly accurate non-intrusive in-flight measurement techniques.

  12. Inter-arch digital model vs. manual cast measurements: Accuracy and reliability.

    Science.gov (United States)

    Kiviahde, Heikki; Bukovac, Lea; Jussila, Päivi; Pesonen, Paula; Sipilä, Kirsi; Raustia, Aune; Pirttiniemi, Pertti

    2017-06-28

    The purpose of this study was to evaluate the accuracy and reliability of inter-arch measurements using digital dental models and conventional dental casts. Thirty sets of dental casts with permanent dentition were examined. Manual measurements were done with a digital caliper directly on the dental casts, and digital measurements were made on 3D models by two independent examiners. Intra-class correlation coefficients (ICC), a paired sample t-test or Wilcoxon signed-rank test, and Bland-Altman plots were used to evaluate intra- and inter-examiner error and to determine the accuracy and reliability of the measurements. The ICC values were generally good for manual and excellent for digital measurements. The Bland-Altman plots of all the measurements showed good agreement between the manual and digital methods and excellent inter-examiner agreement using the digital method. Inter-arch occlusal measurements on digital models are accurate and reliable and are superior to manual measurements.

  13. Accuracy and Reliability of Cone-Beam Computed Tomography for Linear and Volumetric Mandibular Condyle Measurements. A Human Cadaver Study.

    Science.gov (United States)

    García-Sanz, Verónica; Bellot-Arcís, Carlos; Hernández, Virginia; Serrano-Sánchez, Pedro; Guarinos, Juan; Paredes-Gallardo, Vanessa

    2017-09-20

    The accuracy of Cone-Beam Computed Tomography (CBCT) on linear and volumetric measurements on condyles has only been assessed on dry skulls. The aim of this study was to evaluate the reliability and accuracy of linear and volumetric measurements of mandibular condyles in the presence of soft tissues using CBCT. Six embalmed cadaver heads were used. CBCT scans were taken, followed by the extraction of the condyles. The water displacement technique was used to calculate the volumes of the condyles and three linear measurements were made using a digital caliper, these measurements serving as the gold standard. Surface models of the condyles were obtained using a 3D scanner, and superimposed onto the CBCT images. Condyles were isolated on the CBCT render volume using the surface models as reference and volumes were measured. Linear measurements were made on CBCT slices. The CBCT method was found to be reliable for both volumetric and linear measurements (CV  0.90). Highly accurate values were obtained for the three linear measurements and volume. CBCT is a reliable and accurate method for taking volumetric and linear measurements on mandibular condyles in the presence of soft tissue, and so a valid tool for clinical diagnosis.

  14. 3D-Laser-Scanning Technique Applied to Bulk Density Measurements of Apollo Lunar Samples

    Science.gov (United States)

    Macke, R. J.; Kent, J. J.; Kiefer, W. S.; Britt, D. T.

    2015-01-01

    In order to better interpret gravimetric data from orbiters such as GRAIL and LRO to understand the subsurface composition and structure of the lunar crust, it is import to have a reliable database of the density and porosity of lunar materials. To this end, we have been surveying these physical properties in both lunar meteorites and Apollo lunar samples. To measure porosity, both grain density and bulk density are required. For bulk density, our group has historically utilized sub-mm bead immersion techniques extensively, though several factors have made this technique problematic for our work with Apollo samples. Samples allocated for measurement are often smaller than optimal for the technique, leading to large error bars. Also, for some samples we were required to use pure alumina beads instead of our usual glass beads. The alumina beads were subject to undesirable static effects, producing unreliable results. Other investigators have tested the use of 3d laser scanners on meteorites for measuring bulk volumes. Early work, though promising, was plagued with difficulties including poor response on dark or reflective surfaces, difficulty reproducing sharp edges, and large processing time for producing shape models. Due to progress in technology, however, laser scanners have improved considerably in recent years. We tested this technique on 27 lunar samples in the Apollo collection using a scanner at NASA Johnson Space Center. We found it to be reliable and more precise than beads, with the added benefit that it involves no direct contact with the sample, enabling the study of particularly friable samples for which bead immersion is not possible

  15. The verification tests of residual radioactivity measurement and assessment techniques for buildings and soils

    International Nuclear Information System (INIS)

    Onozawa, T.; Ishikura, T.; Yoshimura, Yukio; Nakazawa, M.; Makino, S.; Urayama, K.; Kawasaki, S.

    1996-01-01

    According to the standard procedure for decommissioning a commercial nuclear power plant (CNPP) in Japan, controlled areas will be released for unrestricted use before the dismantling of a reactor building. If manual survey and sampling techniques were applied to measurement for unrestricted release on and in the extensive surface of the building, much time and much specialized labor would be required to assess the appropriateness of the releasing. Therefore the authors selected the following three techniques for demonstrating reliability and applicability of the techniques for CNPPs: (1) technique of assessing radioactive concentration distribution on the surface of buildings (ADB); (2) technique of assessing radioactive permeation distribution in the concrete structure of buildings (APB); (3) technique of assessing radioactive concentration distribution in soil (ADS). These tests include the techniques of measuring and assessing very low radioactive concentration distribution on the extensive surfaces of buildings and the soil surrounding of a plant with automatic devices. Technical investigation and preliminary study of the verification tests were started in 1990. In the study, preconditions were clarified for each technique and the performance requirements were set up. Moreover, simulation models have been constructed for several feasible measurement method to assess their performance in terms of both measurement test and simulation analysis. Fundamental tests have been under way using small-scale apparatuses since 1994

  16. PET-MR image fusion in soft tissue sarcoma: accuracy, reliability and practicality of interactive point-based and automated mutual information techniques

    International Nuclear Information System (INIS)

    Somer, Edward J.R.; Marsden, Paul K.; Benatar, Nigel A.; O'Doherty, Michael J.; Goodey, Joanne; Smith, Michael A.

    2003-01-01

    The fusion of functional positron emission tomography (PET) data with anatomical magnetic resonance (MR) or computed tomography images, using a variety of interactive and automated techniques, is becoming commonplace, with the technique of choice dependent on the specific application. The case of PET-MR image fusion in soft tissue is complicated by a lack of conspicuous anatomical features and deviation from the rigid-body model. Here we compare a point-based external marker technique with an automated mutual information algorithm and discuss the practicality, reliability and accuracy of each when applied to the study of soft tissue sarcoma. Ten subjects with suspected sarcoma in the knee, thigh, groin, flank or back underwent MR and PET scanning after the attachment of nine external fiducial markers. In the assessment of the point-based technique, three error measures were considered: fiducial localisation error (FLE), fiducial registration error (FRE) and target registration error (TRE). FLE, which represents the accuracy with which the fiducial points can be located, is related to the FRE minimised by the registration algorithm. The registration accuracy is best characterised by the TRE, which is the distance between corresponding points in each image space after registration. In the absence of salient features within the target volume, the TRE can be measured at fiducials excluded from the registration process. To assess the mutual information technique, PET data, acquired after physically removing the markers, were reconstructed in a variety of ways and registered with MR. Having applied the transform suggested by the algorithm to the PET scan acquired before the markers were removed, the residual distance between PET and MR marker-pairs could be measured. The manual point-based technique yielded the best results (RMS TRE =8.3 mm, max =22.4 mm, min =1.7 mm), performing better than the automated algorithm (RMS TRE =20.0 mm, max =30.5 mm, min =7.7 mm) when

  17. Measurement-based reliability/performability models

    Science.gov (United States)

    Hsueh, Mei-Chen

    1987-01-01

    Measurement-based models based on real error-data collected on a multiprocessor system are described. Model development from the raw error-data to the estimation of cumulative reward is also described. A workload/reliability model is developed based on low-level error and resource usage data collected on an IBM 3081 system during its normal operation in order to evaluate the resource usage/error/recovery process in a large mainframe system. Thus, both normal and erroneous behavior of the system are modeled. The results provide an understanding of the different types of errors and recovery processes. The measured data show that the holding times in key operational and error states are not simple exponentials and that a semi-Markov process is necessary to model the system behavior. A sensitivity analysis is performed to investigate the significance of using a semi-Markov process, as opposed to a Markov process, to model the measured system.

  18. Two-detector cross-correlation noise technique and its application in measuring reactor kinetic parameters

    International Nuclear Information System (INIS)

    Lu Guiping; Peng Feng; Yi Jieyi

    1988-01-01

    The two-detector cross-correlation noise technique is a new method of measuring reactor kinetic parameters developed in the sixties. It has the advantages of non-perturbation in core, high signal to noise ratio, low space dependent effect, and simple and reliable in measurement. A special set of cross-correlation analyzer has been prepared for measuring kinetic parameters of several reactor assemblies, such as the High Flux Engineering Test Reactor, its zero power mock up facility and a low enriched uranium light water lattice zero power facility

  19. Nanoscale deformation measurements for reliability assessment of material interfaces

    Science.gov (United States)

    Keller, Jürgen; Gollhardt, Astrid; Vogel, Dietmar; Michel, Bernd

    2006-03-01

    With the development and application of micro/nano electronic mechanical systems (MEMS, NEMS) for a variety of market segments new reliability issues will arise. The understanding of material interfaces is the key for a successful design for reliability of MEMS/NEMS and sensor systems. Furthermore in the field of BIOMEMS newly developed advanced materials and well known engineering materials are combined despite of fully developed reliability concepts for such devices and components. In addition the increasing interface-to volume ratio in highly integrated systems and nanoparticle filled materials are challenges for experimental reliability evaluation. New strategies for reliability assessment on the submicron scale are essential to fulfil the needs of future devices. In this paper a nanoscale resolution experimental method for the measurement of thermo-mechanical deformation at material interfaces is introduced. The determination of displacement fields is based on scanning probe microscopy (SPM) data. In-situ SPM scans of the analyzed object (i.e. material interface) are carried out at different thermo-mechanical load states. The obtained images are compared by grayscale cross correlation algorithms. This allows the tracking of local image patterns of the analyzed surface structure. The measurement results are full-field displacement fields with nanometer resolution. With the obtained data the mixed mode type of loading at material interfaces can be analyzed with highest resolution for future needs in micro system and nanotechnology.

  20. A study on maintenance reliability allocation of urban transit brake system using hybrid neuro-genetic technique

    International Nuclear Information System (INIS)

    Bae, Chul Ho; Kim, Hyun Jun; Lee, Jung Hwan; Suh, Myung Won; Chu, Yul

    2007-01-01

    For reasonable establishing of maintenance strategies, safety security and cost limitation must be considered at the same time. In this paper, the concept of system reliability introduces and optimizes as the key of reasonable maintenance strategies. This study aims at optimizing component's reliability that satisfies the target reliability of brake system in the urban transit. First of all, constructed reliability evaluation system is used to predict and analyze reliability. This data is used for the optimization. To identify component reliability in a system, a method is presented in this paper which uses hybrid neuro-genetic technique. Feed-forward multi-layer neural networks trained by back propagation are used to find out the relationship between component reliability (input) and system reliability (output) of a structural system. The inverse problem can be formulated by using neural network. Genetic algorithm is used to find the minimum square error. Finally, this paper presents reasonable maintenance cycle of urban transit brake system by using optimal system reliability

  1. Reliability analysis of large scaled structures by optimization technique

    International Nuclear Information System (INIS)

    Ishikawa, N.; Mihara, T.; Iizuka, M.

    1987-01-01

    This paper presents a reliability analysis based on the optimization technique using PNET (Probabilistic Network Evaluation Technique) method for the highly redundant structures having a large number of collapse modes. This approach makes the best use of the merit of the optimization technique in which the idea of PNET method is used. The analytical process involves the minimization of safety index of the representative mode, subjected to satisfaction of the mechanism condition and of the positive external work. The procedure entails the sequential performance of a series of the NLP (Nonlinear Programming) problems, where the correlation condition as the idea of PNET method pertaining to the representative mode is taken as an additional constraint to the next analysis. Upon succeeding iterations, the final analysis is achieved when a collapse probability at the subsequent mode is extremely less than the value at the 1st mode. The approximate collapse probability of the structure is defined as the sum of the collapse probabilities of the representative modes classified by the extent of correlation. Then, in order to confirm the validity of the proposed method, the conventional Monte Carlo simulation is also revised by using the collapse load analysis. Finally, two fairly large structures were analyzed to illustrate the scope and application of the approach. (orig./HP)

  2. Filtering technique for detection and identification of measurement failures in nuclear power plants

    International Nuclear Information System (INIS)

    Racz, A.

    1989-11-01

    The basic requirement of the safe operation of nuclear power plants (NPP) is to have reliable information on all quantities that can be measured, monitored or controlled during the operation. Kalman filtering techniques have been applied for prompt detection and identification of failures in the measurement systems used in NPPs. Mathematical basis of Kalman filtering and various models applied to failure detection are overviewed. The applicability of some models are evaluated by real results of NPP measurements. A sample system for an NPP is suggested, based on several numerical tests. (R.P.) 23 refs.; 40 figs.; 2 tabs

  3. Is linear distance measured by panoramic radiography reliable?

    International Nuclear Information System (INIS)

    Nishikawa, Keiichi; Wakoh, Mamoru; Sano, Tsukasa; Suehiro, Atsushi; Sekine, Hideshi; Kousuge, Yuuji

    2010-01-01

    The objective of this study was to re-examine the reliability of distance measurements on clinical panoramic radiographs by comparing them with computed tomography (CT) images, from which the most accurate distance measurement is possible. Twenty pairs of images from patients examined both with panoramic radiography and CT for dental implant treatment planning in the premolar and molar regions of the mandible were used. The vertical linear distance between the alveolar crest and the closest mandibular canal was measured by three experienced oral radiologists on both images. The distances measured on panoramic radiographs were corrected for the magnification factor at the focal plane. Double-oblique cross-sectional images were used for CT. Pearson's correlation coefficient was calculated between distances obtained from both images. The paired t test was performed for statistical comparison. Error levels with the panoramic radiograph versus the CT image were also calculated. Pearson's correlation coefficient showed a significant strong linear correlation (R=0.90; p<0.01). However, the corrected value of distance measured on panoramic radiographs tended to be too small, and a significant difference was observed (p<0.05). The error level was approximately 10% (9.6±7.3%). Distance measurement on clinical panoramic radiographs is less reliable than CT images and cannot be recommended. (author)

  4. Cyclical Annealing Technique To Enhance Reliability of Amorphous Metal Oxide Thin Film Transistors.

    Science.gov (United States)

    Chen, Hong-Chih; Chang, Ting-Chang; Lai, Wei-Chih; Chen, Guan-Fu; Chen, Bo-Wei; Hung, Yu-Ju; Chang, Kuo-Jui; Cheng, Kai-Chung; Huang, Chen-Shuo; Chen, Kuo-Kuang; Lu, Hsueh-Hsing; Lin, Yu-Hsin

    2018-02-26

    This study introduces a cyclical annealing technique that enhances the reliability of amorphous indium-gallium-zinc-oxide (a-IGZO) via-type structure thin film transistors (TFTs). By utilizing this treatment, negative gate-bias illumination stress (NBIS)-induced instabilities can be effectively alleviated. The cyclical annealing provides several cooling steps, which are exothermic processes that can form stronger ionic bonds. An additional advantage is that the total annealing time is much shorter than when using conventional long-term annealing. With the use of cyclical annealing, the reliability of the a-IGZO can be effectively optimized, and the shorter process time can increase fabrication efficiency.

  5. Reliability and Inequality Measures for the Weimal Distribution ...

    African Journals Online (AJOL)

    ). This article aimed at discussing both reliability and inequality measures from the Weimal distribution. The work has derived and discussed theoretically, expressions for the survival and hazard function of the Weimal distribution. The ordinary ...

  6. NDE reliability gains from combining eddy-current and ultrasonic testing

    International Nuclear Information System (INIS)

    Horn, D.; Mayo, W.R.

    1999-01-01

    We investigate statistical methods for combining the results of two complementary inspection techniques, eddy-current and ultrasonic testing. The reliability of rejection/acceptance decisions based on combined information is compared with that based on each inspection technique individually. The measured reliability increases with the amount of information incorporated in the decision. (author)

  7. Advances in reliability and system engineering

    CERN Document Server

    Davim, J

    2017-01-01

    This book presents original studies describing the latest research and developments in the area of reliability and systems engineering. It helps the reader identifying gaps in the current knowledge and presents fruitful areas for further research in the field. Among others, this book covers reliability measures, reliability assessment of multi-state systems, optimization of multi-state systems, continuous multi-state systems, new computational techniques applied to multi-state systems and probabilistic and non-probabilistic safety assessment.

  8. Reliability measures in item response theory: manifest versus latent correlation functions.

    Science.gov (United States)

    Milanzi, Elasma; Molenberghs, Geert; Alonso, Ariel; Verbeke, Geert; De Boeck, Paul

    2015-02-01

    For item response theory (IRT) models, which belong to the class of generalized linear or non-linear mixed models, reliability at the scale of observed scores (i.e., manifest correlation) is more difficult to calculate than latent correlation based reliability, but usually of greater scientific interest. This is not least because it cannot be calculated explicitly when the logit link is used in conjunction with normal random effects. As such, approximations such as Fisher's information coefficient, Cronbach's α, or the latent correlation are calculated, allegedly because it is easy to do so. Cronbach's α has well-known and serious drawbacks, Fisher's information is not meaningful under certain circumstances, and there is an important but often overlooked difference between latent and manifest correlations. Here, manifest correlation refers to correlation between observed scores, while latent correlation refers to correlation between scores at the latent (e.g., logit or probit) scale. Thus, using one in place of the other can lead to erroneous conclusions. Taylor series based reliability measures, which are based on manifest correlation functions, are derived and a careful comparison of reliability measures based on latent correlations, Fisher's information, and exact reliability is carried out. The latent correlations are virtually always considerably higher than their manifest counterparts, Fisher's information measure shows no coherent behaviour (it is even negative in some cases), while the newly introduced Taylor series based approximations reflect the exact reliability very closely. Comparisons among the various types of correlations, for various IRT models, are made using algebraic expressions, Monte Carlo simulations, and data analysis. Given the light computational burden and the performance of Taylor series based reliability measures, their use is recommended. © 2014 The British Psychological Society.

  9. Reliability of Rehabilitative Ultrasonography to Measure Transverse Abdominis and Multifidus Muscle Dimensions

    International Nuclear Information System (INIS)

    Nabavi, Narjes; Mosallanezhad, Zahra; Haghighatkhah, Hamid Reza; Mohseni Bandpeid, Mohammad Ali

    2014-01-01

    Lumbar paraspinal muscles play an important role in providing both mobility and stability during dynamic tasks. Among paraspinal muscles, transverse abdominis and lumbar multifidus have been of particular interest as active stabilizers of the lumbar spine. These muscles may become dysfunctional in chronic low back pain (CLBP). Low back injury can result in muscle inhibition and control loss that cannot recover spontaneously, and specific exercises are required to stimulate their recovery. The purpose of this study was to test the reliability of ultrasonography to measure muscle dimensions and to present a reliable method for measuring transverse abdominis and lumbar multifidus as stabilizing muscles of the lumbar spine. Fifteen healthy participants (18-55 year olds) were evaluated by a radiologist using ultrasonography (ES500) with two probes (50mm linear 7.5 MHZ and 70 mm curvilinear 3.5 MHz). The muscle thickness of transverse abdominis and the anterior-posterior diameter and cross sectional area of the LMF were measured. To determine within and between days reliabilities, second and third measurements were repeated with half an hour and one week intervals, respectively. Intraclass correlation coefficient for left and right showed good to high reliability for the cross sectional area of lumbar multifidi (0.74 and 0.88, respectively) as well as the anterior-posterior dimensions of lumbar multifidi (0.89 and 0.91, respectively) and transverse abdomini thickness (0.73 and 0.85, respectively). Rehabilitative ultrasonography is a reliable and non-invasive instrument to measure muscle thickness. The method used in this study is a reliable way to measure lumbar stabilizing muscles

  10. A Study on the Reliability of Sasang Constitutional Body Trunk Measurement

    Directory of Open Access Journals (Sweden)

    Eunsu Jang

    2012-01-01

    Full Text Available Objective. Body trunk measurement for human plays an important diagnostic role not only in conventional medicine but also in Sasang constitutional medicine (SCM. The Sasang constitutional body trunk measurement (SCBTM consists of the 5-widths and the 8-circumferences which are standard locations currently employed in the SCM society. This study suggests to what extent a comprehensive training can improve the reliability of the SCBTM. Methods. We recruited 10 male subjects and 5 male observers with no experience of anthropometric measurement. We conducted measurements twice before and after a comprehensive training. Relative technical error of measurement (%TEMs was produced to assess intra and inter observer reliabilities. Results. Post-training intra-observer %TEMs of the SCBTM were 0.27% to 1.85% reduced from 0.27% to 6.26% in pre-training, respectively. Post-training inter-observer %TEMs of those were 0.56% to 1.66% reduced from 1.00% to 9.60% in pre-training, respectively. Post-training % total TEMs which represent the whole reliability were 0.68% to 2.18% reduced from maximum value of 10.18%. Conclusion. A comprehensive training makes the SCBTM more reliable, hence giving a sufficiently confident diagnostic tool. It is strongly recommended to give a comprehensive training in advance to take the SCBTM.

  11. A study on the reliability of sasang constitutional body trunk measurement.

    Science.gov (United States)

    Jang, Eunsu; Kim, Jong Yeol; Lee, Haejung; Kim, Honggie; Baek, Younghwa; Lee, Siwoo

    2012-01-01

    Objective. Body trunk measurement for human plays an important diagnostic role not only in conventional medicine but also in Sasang constitutional medicine (SCM). The Sasang constitutional body trunk measurement (SCBTM) consists of the 5-widths and the 8-circumferences which are standard locations currently employed in the SCM society. This study suggests to what extent a comprehensive training can improve the reliability of the SCBTM. Methods. We recruited 10 male subjects and 5 male observers with no experience of anthropometric measurement. We conducted measurements twice before and after a comprehensive training. Relative technical error of measurement (%TEMs) was produced to assess intra and inter observer reliabilities. Results. Post-training intra-observer %TEMs of the SCBTM were 0.27% to 1.85% reduced from 0.27% to 6.26% in pre-training, respectively. Post-training inter-observer %TEMs of those were 0.56% to 1.66% reduced from 1.00% to 9.60% in pre-training, respectively. Post-training % total TEMs which represent the whole reliability were 0.68% to 2.18% reduced from maximum value of 10.18%. Conclusion. A comprehensive training makes the SCBTM more reliable, hence giving a sufficiently confident diagnostic tool. It is strongly recommended to give a comprehensive training in advance to take the SCBTM.

  12. Reliability analysis framework for computer-assisted medical decision systems

    International Nuclear Information System (INIS)

    Habas, Piotr A.; Zurada, Jacek M.; Elmaghraby, Adel S.; Tourassi, Georgia D.

    2007-01-01

    We present a technique that enhances computer-assisted decision (CAD) systems with the ability to assess the reliability of each individual decision they make. Reliability assessment is achieved by measuring the accuracy of a CAD system with known cases similar to the one in question. The proposed technique analyzes the feature space neighborhood of the query case to dynamically select an input-dependent set of known cases relevant to the query. This set is used to assess the local (query-specific) accuracy of the CAD system. The estimated local accuracy is utilized as a reliability measure of the CAD response to the query case. The underlying hypothesis of the study is that CAD decisions with higher reliability are more accurate. The above hypothesis was tested using a mammographic database of 1337 regions of interest (ROIs) with biopsy-proven ground truth (681 with masses, 656 with normal parenchyma). Three types of decision models, (i) a back-propagation neural network (BPNN), (ii) a generalized regression neural network (GRNN), and (iii) a support vector machine (SVM), were developed to detect masses based on eight morphological features automatically extracted from each ROI. The performance of all decision models was evaluated using the Receiver Operating Characteristic (ROC) analysis. The study showed that the proposed reliability measure is a strong predictor of the CAD system's case-specific accuracy. Specifically, the ROC area index for CAD predictions with high reliability was significantly better than for those with low reliability values. This result was consistent across all decision models investigated in the study. The proposed case-specific reliability analysis technique could be used to alert the CAD user when an opinion that is unlikely to be reliable is offered. The technique can be easily deployed in the clinical environment because it is applicable with a wide range of classifiers regardless of their structure and it requires neither additional

  13. A Community Based Study to Test the Reliability and Validity of Physical Activity Measurement Techniques

    Directory of Open Access Journals (Sweden)

    Puneet Misra

    2014-01-01

    Full Text Available Introduction: Physical activity (PA is protective against non-communicable diseases and it can reduce premature mortality. However, it is difficult to assess the frequency, duration, type and intensity of PA. The global physical activity questionnaire (GPAQ has been developed by World Health Organization with the aim of having valid and reliable estimates of PA. The primary aim of this study is to assess the repeatability of the GPAQ instrument and the secondary aim is to validate it against International Physical Activity Questionnaire (IPAQ and against an objective measure of PA (i.e., using pedometers in both rural and peri-urban areas of North India. Methods: A total of 262 subjects were recruited by random selection from Ballabgarh Block of Haryana State in India. For test retest repeatability of GPAQ and IPAQ, the instruments were administered on two occasions separated by at least 3 days. For concurrent validity, both questionnaires were administered in random order and for criterion validity step counters were used. Spearman′s correlation coefficient, intra-class correlation (ICC and Cohen′s kappa was used in the analysis. Results: For GPAQ validity, the spearman′s Rho ranged from 0.40 to 0.59 and ICC ranged from 0.43 to 0.81 while for IPAQ validity, spearman correlation coefficient ranged from 0.42 to 0.43 and ICC ranged from 0.56 to 0.68. The observed concurrent validity coefficients suggested that both the questionnaires had reasonable agreement (Spearman Rho of >0.90; P < 0.0001; ICC: 0.76-0.91, P < 0.05. Conclusions: GPAQ is similar to IPAQ in measuring PA and can be used for measurement of PA in community settings.

  14. The role of test-retest reliability in measuring individual and group differences in executive functioning.

    Science.gov (United States)

    Paap, Kenneth R; Sawi, Oliver

    2016-12-01

    Studies testing for individual or group differences in executive functioning can be compromised by unknown test-retest reliability. Test-retest reliabilities across an interval of about one week were obtained from performance in the antisaccade, flanker, Simon, and color-shape switching tasks. There is a general trade-off between the greater reliability of single mean RT measures, and the greater process purity of measures based on contrasts between mean RTs in two conditions. The individual differences in RT model recently developed by Miller and Ulrich was used to evaluate the trade-off. Test-retest reliability was statistically significant for 11 of the 12 measures, but was of moderate size, at best, for the difference scores. The test-retest reliabilities for the Simon and flanker interference scores were lower than those for switching costs. Standard practice evaluates the reliability of executive-functioning measures using split-half methods based on data obtained in a single day. Our test-retest measures of reliability are lower, especially for difference scores. These reliability measures must also take into account possible day effects that classical test theory assumes do not occur. Measures based on single mean RTs tend to have acceptable levels of reliability and convergent validity, but are "impure" measures of specific executive functions. The individual differences in RT model shows that the impurity problem is worse than typically assumed. However, the "purer" measures based on difference scores have low convergent validity that is partly caused by deficiencies in test-retest reliability. Copyright © 2016 Elsevier B.V. All rights reserved.

  15. The Reliability of a Novel Mobile 3-dimensional Wound Measurement Device.

    Science.gov (United States)

    Anghel, Ersilia L; Kumar, Anagha; Bigham, Thomas E; Maselli, Kathryn M; Steinberg, John S; Evans, Karen K; Kim, Paul J; Attinger, Christopher E

    2016-11-01

    Objective assessment of wound dimensions is essential for tracking progression and determining treatment effectiveness. A reliability study was designed to establish intrarater and interrater reliability of a novel mobile 3-dimensional wound measurement (3DWM) device. Forty-five wounds were assessed by 2 raters using a 3DWM device to obtain length, width, area, depth, and volume measurements. Wounds were also measured manually, using a disposable ruler and digital planimetry. The intraclass correlation coefficient (ICC) was used to establish intrarater and interrater reliability. High levels of intrarater and interrater agreement were observed for area, length, and width; ICC = 0.998, 0.977, 0.955 and 0.999, 0.997, 0.995, respectively. Moderate levels of intrarater (ICC = 0.888) and interrater (ICC = 0.696) agreement were observed for volume. Lastly, depth yielded an intrarater ICC of 0.360 and an interrater ICC of 0.649. Measures from the 3DWM device were highly correlated with those obtained from scaled photography for length, width, and area (ρ = 0.997, 0.988, 0.997, P device yielded correlations of ρ = 0.990, 0.987, 0.996 with P device was found to be highly reliable for measuring wound areas for a range of wound sizes and types as compared to manual measurement and digital planimetry. The depth and therefore volume measurement using the 3DWM device was found to have a lower ICC, but volume ICC alone was moderate. Overall, this device offers a mobile option for objective wound measurement in the clinical setting.

  16. Circuit design for reliability

    CERN Document Server

    Cao, Yu; Wirth, Gilson

    2015-01-01

    This book presents physical understanding, modeling and simulation, on-chip characterization, layout solutions, and design techniques that are effective to enhance the reliability of various circuit units.  The authors provide readers with techniques for state of the art and future technologies, ranging from technology modeling, fault detection and analysis, circuit hardening, and reliability management. Provides comprehensive review on various reliability mechanisms at sub-45nm nodes; Describes practical modeling and characterization techniques for reliability; Includes thorough presentation of robust design techniques for major VLSI design units; Promotes physical understanding with first-principle simulations.

  17. Reliability and Validity of Finger Strength and Endurance Measurements in Rock Climbing

    Science.gov (United States)

    Michailov, Michail Lubomirov; Baláš, Jirí; Tanev, Stoyan Kolev; Andonov, Hristo Stoyanov; Kodejška, Jan; Brown, Lee

    2018-01-01

    Purpose: An advanced system for the assessment of climbing-specific performance was developed and used to: (a) investigate the effect of arm fixation (AF) on construct validity evidence and reliability of climbing-specific finger-strength measurement; (b) assess reliability of finger-strength and endurance measurements; and (c) evaluate the…

  18. Sonographic measurements of the achilles tendon, plantar fascia, and heel fat pad are reliable: A test-retest intra- and intertester study.

    Science.gov (United States)

    Johannsen, Finn; Jensen, Signe; Stallknecht, Sandra E; Olsen, Lars Otto; Magnusson, S Peter

    2016-10-01

    To determine intra- and interobserver reliability and precision of sonographic (US) scanning in measuring thickness of the Achilles tendon, plantar fascia, and heel fat pad in patients with heel pain. Seventeen consecutive patients referred with heel pain were included. Two evaluators blinded to the diagnosis performed independently US scanning of both feet without any dialogue with the patient. The examiner left the room, and the next examiner entered. All patients had two US scans performed by each examiner. Two months later, the US images were randomly presented to the evaluators for measurements. Reliability and agreement were assessed by calculation of intraclass correlation coefficient (ICC), 95% limits of agreement (LOA), and typical error (TE). LOA was calculated as a percentage of the mean thickness of each structure to obtain a unitless parameter. We found excellent intratester reliability (ICC 0.78-0.98) and good intertester reliability using one measurement (ICC 0.72-0.91) and excellent (ICC 0.85-0.95) when using average of two measurements. The intratester agreements were good with LOA: 9.5-23.4% and TE: 3.4-8.4%. The intertester agreements were acceptable using one measurement with LOA: 16.1-36.4%, and better using two measurements with LOA: 14.4-33.2%. US is a reliable technique of measurement in the daily clinic, and one single measurement is sufficient. In research, we recommend that the same observer performs the US measurements, if one single scanning is preferred; if more researchers are involved, the average measurement of two US scans is recommended. © 2016 Wiley Periodicals, Inc. J Clin Ultrasound 44:480-486, 2016. © 2016 Wiley Periodicals, Inc.

  19. Designing high availability systems DFSS and classical reliability techniques with practical real life examples

    CERN Document Server

    Taylor, Zachary

    2014-01-01

    A practical, step-by-step guide to designing world-class, high availability systems using both classical and DFSS reliability techniques Whether designing telecom, aerospace, automotive, medical, financial, or public safety systems, every engineer aims for the utmost reliability and availability in the systems he, or she, designs. But between the dream of world-class performance and reality falls the shadow of complexities that can bedevil even the most rigorous design process. While there are an array of robust predictive engineering tools, there has been no single-source guide to understan

  20. Statistical Primer for Athletic Trainers: The Essentials of Understanding Measures of Reliability and Minimal Important Change.

    Science.gov (United States)

    Riemann, Bryan L; Lininger, Monica R

    2018-01-01

      To describe the concepts of measurement reliability and minimal important change.   All measurements have some magnitude of error. Because clinical practice involves measurement, clinicians need to understand measurement reliability. The reliability of an instrument is integral in determining if a change in patient status is meaningful.   Measurement reliability is the extent to which a test result is consistent and free of error. Three perspectives of reliability-relative reliability, systematic bias, and absolute reliability-are often reported. However, absolute reliability statistics, such as the minimal detectable difference, are most relevant to clinicians because they provide an expected error estimate. The minimal important difference is the smallest change in a treatment outcome that the patient would identify as important.   Clinicians should use absolute reliability characteristics, preferably the minimal detectable difference, to determine the extent of error around a patient's measurement. The minimal detectable difference, coupled with an appropriately estimated minimal important difference, can assist the practitioner in identifying clinically meaningful changes in patients.

  1. Tactile acuity charts: a reliable measure of spatial acuity.

    Science.gov (United States)

    Bruns, Patrick; Camargo, Carlos J; Campanella, Humberto; Esteve, Jaume; Dinse, Hubert R; Röder, Brigitte

    2014-01-01

    For assessing tactile spatial resolution it has recently been recommended to use tactile acuity charts which follow the design principles of the Snellen letter charts for visual acuity and involve active touch. However, it is currently unknown whether acuity thresholds obtained with this newly developed psychophysical procedure are in accordance with established measures of tactile acuity that involve passive contact with fixed duration and control of contact force. Here we directly compared tactile acuity thresholds obtained with the acuity charts to traditional two-point and grating orientation thresholds in a group of young healthy adults. For this purpose, two types of charts, using either Braille-like dot patterns or embossed Landolt rings with different orientations, were adapted from previous studies. Measurements with the two types of charts were equivalent, but generally more reliable with the dot pattern chart. A comparison with the two-point and grating orientation task data showed that the test-retest reliability of the acuity chart measurements after one week was superior to that of the passive methods. Individual thresholds obtained with the acuity charts agreed reasonably with the grating orientation threshold, but less so with the two-point threshold that yielded relatively distinct acuity estimates compared to the other methods. This potentially considerable amount of mismatch between different measures of tactile acuity suggests that tactile spatial resolution is a complex entity that should ideally be measured with different methods in parallel. The simple test procedure and high reliability of the acuity charts makes them a promising complement and alternative to the traditional two-point and grating orientation thresholds.

  2. Human reliability

    International Nuclear Information System (INIS)

    Embrey, D.E.

    1987-01-01

    Concepts and techniques of human reliability have been developed and are used mostly in probabilistic risk assessment. For this, the major application of human reliability assessment has been to identify the human errors which have a significant effect on the overall safety of the system and to quantify the probability of their occurrence. Some of the major issues within human reliability studies are reviewed and it is shown how these are applied to the assessment of human failures in systems. This is done under the following headings; models of human performance used in human reliability assessment, the nature of human error, classification of errors in man-machine systems, practical aspects, human reliability modelling in complex situations, quantification and examination of human reliability, judgement based approaches, holistic techniques and decision analytic approaches. (UK)

  3. Reliability and concurrent validity of postural asymmetry measurement in adolescent idiopathic scoliosis.

    Science.gov (United States)

    Prowse, Ashleigh; Aslaksen, Berit; Kierkegaard, Marie; Furness, James; Gerdhem, Paul; Abbott, Allan

    2017-01-18

    To investigate the reliability and concurrent validity of the Baseline ® Body Level/Scoliosis meter for adolescent idiopathic scoliosis postural assessment in three anatomical planes. This is an observational reliability and concurrent validity study of adolescent referrals to the Orthopaedic department for scoliosis screening at Karolinska University Hospital, Stockholm, Sweden between March-May 2012. A total of 31 adolescents with idiopathic scoliosis (13.6 ± 0.6 years old) of mild-moderate curvatures (25° ± 12°) were consecutively recruited. Measurement of cervical, thoracic and lumbar curvatures, pelvic and shoulder tilt, and axial thoracic rotation (ATR) were performed by two trained physiotherapists in one day. The intraclass correlation coefficient (ICC) was used to determine the inter-examiner reliability (ICC2,1) and the intra-rater reliability (ICC3,3) of the Baseline ® Body Level/Scoliosis meter. Spearman's correlation analyses were used to estimate concurrent validity between the Baseline ® Body Level/Scoliosis meter and Gold Standard Cobb angles from radiographs and the Orthopaedic Systems Inc. Scoliometer. There was excellent reliability between examiners for thoracic kyphosis (ICC2,1 = 0.94), ATR (ICC2,1 = 0.92) and lumbar lordosis (ICC2,1 = 0.79). There was adequate reliability between examiners for cervical lordosis (ICC2,1 = 0.51), however poor reliability for pelvic and shoulder tilt. Both devices were reproducible in the measurement of ATR when repeated by one examiner (ICC3,3 0.98-1.00). The device had a good correlation with the Scoliometer (rho = 0.78). When compared with Cobb angle from radiographs, there was a moderate correlation for ATR (rho = 0.627). The Baseline ® Body Level/Scoliosis meter provides reliable transverse and sagittal cervical, thoracic and lumbar measurements and valid transverse plan measurements of mild-moderate scoliosis deformity.

  4. Self-report measures of prospective memory are reliable but not valid.

    Science.gov (United States)

    Uttl, Bob; Kibreab, Mekale

    2011-03-01

    Are self-report measures of prospective memory (ProM) reliable and valid? To examine this question, 240 undergraduate student volunteers completed several widely used self-report measures of ProM including the Prospective Memory Questionnaire (PMQ), the Prospective and Retrospective Memory Questionnaire (PRMQ), the Comprehensive Assessment of Prospective Memory (CAPM) questionnaire, self-reports of retrospective memory (RetM), objective measures of ProM and RetM, and measures of involvement in activities and events, memory strategies and aids use, personality and verbal intelligence. The results showed that both convergent and divergent validity of ProM self-reports are poor, even though we assessed ProM using a newly developed, reliable continuous measure. Further analyses showed that a substantial proportion of variability in ProM self-report scores was due to verbal intelligence, personality (conscientiousness, neuroticism), activities and event involvement (busyness), and use of memory strategies and aids. ProM self-reports have adequate reliability, but poor validity and should not be interpreted as reflecting ProM ability. (PsycINFO Database Record (c) 2011 APA, all rights reserved).

  5. Research on application of technique for analyzing system reliability, GO-FLOW

    International Nuclear Information System (INIS)

    Matsuoka, Takeshi; Fukuto, Junji; Sugasawa, Shinobu; Mitomo, Nobuo; Miyazaki, Keiko; Hirao, Yoshihiro; Kobayashi, Michiyuki

    1997-01-01

    As the method of evaluation, probabilistic safety assessment (PSA) has been introduced in nuclear power field, and began to play important role in plant design and safety examination. In the Ship Research Institute, as the technique for analyzing system reliability which takes the main part of PSA, the research on developing the GO-FLOW technique which has various advanced functions has been carried out. In this research, the functions of the GO-FLOW technique are improved, and the function of the dynamic behavior analysis for systems and the analysis function for the combination of the physical behavior of systems and the change of probabilistic events are developed, further, the function of extracting main accident sequence by utilizing the GO-FLOW technique is prepared. As for the analysis of dynamic behavior, the sample problem on hold-up tank was investigated. As to the extraction of main accident sequence, the fundamental part of the function of event tree analysis was consolidated, and the function of setting branching probability was given. As to the indication of plant behavior, the simulator for improved marine reactor MRX was developed. (K.I.)

  6. THE RELIABILITY AND ACCURACY OF THE TRIPLE MEASUREMENTS OF ANALOG PROCESS VARIABLES

    Directory of Open Access Journals (Sweden)

    V. A. Anishchenko

    2017-01-01

    Full Text Available The increase in unit capacity of electric equipment as well as complication of technological processes, devices control and management of the latter in power plants and substations demonstrate the need to improve the reliability and accuracy of measurement information characterizing the state of the objects being managed. The mentioned objective is particularly important for nuclear power plants, where the price of inaccuracy of measurement responsible process variables is particularly high and the error might lead to irreparable consequences. Improving the reliability and accuracy of measurements along with the improvement of the element base is provided by methods of operational validation. These methods are based on the use of information redundancy (structural, topological, temporal. In particular, information redundancy can be achieved by the simultaneous measurement of one analog variable by two (duplication or three devices (triplication i.e., triple redundancy. The problem of operational control of the triple redundant system of measurement of electrical analog variables (currents, voltages, active and reactive power and energy is considered as a special case of signal processing by an orderly sampling on the basis of majority transformation and transformation being close to majority one. Difficulties in monitoring the reliability of measurements are associated with the two tasks. First, one needs to justify the degree of truncation of the distributions of random errors of measurements and allowable residuals of the pairwise differences of the measurement results. The second task consists in formation of the algorithm of joint processing of a set of separate measurements determined as valid. The quality of control is characterized by the reliability, which adopted the synonym of validity, and accuracy of the measuring system. Taken separately, these indicators might lead to opposite results. A compromise solution is therefore proposed

  7. Reliability of ultrasound thickness measurement of the abdominal muscles during clinical isometric endurance tests.

    Science.gov (United States)

    ShahAli, Shabnam; Arab, Amir Massoud; Talebian, Saeed; Ebrahimi, Esmaeil; Bahmani, Andia; Karimi, Noureddin; Nabavi, Hoda

    2015-07-01

    The study was designed to evaluate the intra-examiner reliability of ultrasound (US) thickness measurement of abdominal muscles activity when supine lying and during two isometric endurance tests in subjects with and without Low back pain (LBP). A total of 19 women (9 with LBP, 10 without LBP) participated in the study. Within-day reliability of the US thickness measurements at supine lying and the two isometric endurance tests were assessed in all subjects. The intra-class correlation coefficient (ICC) was used to assess the relative reliability of thickness measurement. The standard error of measurement (SEM), minimal detectable change (MDC) and the coefficient of variation (CV) were used to evaluate the absolute reliability. Results indicated high ICC scores (0.73-0.99) and also small SEM and MDC scores for within-day reliability assessment. The Bland-Altman plots of agreement in US measurement of the abdominal muscles during the two isometric endurance tests demonstrated that 95% of the observations fall between the limits of agreement for test and retest measurements. Together the results indicate high intra-tester reliability for the US measurement of the thickness of abdominal muscles in all the positions tested. According to the study's findings, US imaging can be used as a reliable method for assessment of abdominal muscles activity in supine lying and the two isometric endurance tests employed, in participants with and without LBP. Copyright © 2014 Elsevier Ltd. All rights reserved.

  8. Test-Retest Reliability of Dual-Task Outcome Measures in People With Parkinson Disease.

    Science.gov (United States)

    Strouwen, Carolien; Molenaar, Esther A L M; Keus, Samyra H J; Münks, Liesbeth; Bloem, Bastiaan R; Nieuwboer, Alice

    2016-08-01

    Dual-task (DT) training is gaining ground as a physical therapy intervention in people with Parkinson disease (PD). Future studies evaluating the effect of such interventions need reliable outcome measures. To date, the test-retest reliability of DT measures in patients with PD remains largely unknown. The purpose of this study was to assess the reliability of DT outcome measures in patients with PD. A repeated-measures design was used. Patients with PD ("on" medication, Mini-Mental State Examination score ≥24) performed 2 cognitive tasks (ie, backward digit span task and auditory Stroop task) and 1 functional task (ie, mobile phone task) in combination with walking. Tasks were assessed at 2 time points (same hour) with an interval of 6 weeks. Test-retest reliability was assessed for gait while performing each secondary task (DT gait) for both cognitive tasks while walking (DT cognitive) and for the functional task while walking (DT functional). Sixty-two patients with PD (age=39-89 years, Hoehn and Yahr stages II-III) were included in the study. Intraclass correlation coefficients (ICCs) showed excellent reliability for DT gait measures, ranging between .86 and .95 when combined with the digit span task, between .86 and .95 when combined with the auditory Stroop task, and between .72 and .90 when combined with the mobile phone task. The standard error of measurements for DT gait speed varied between 0.06 and 0.08 m/s, leading to minimal detectable changes between 0.16 and 0.22 m/s. With regard to DT cognitive measures, reaction times showed good-to-excellent reliability (digit span task: ICC=.75; auditory Stroop task: ICC=.82). The results cannot be generalized to patients with advanced disease or to other DT measures. In people with PD, DT measures proved to be reliable for use in clinical studies and look promising for use in clinical practice to assess improvements after DT training. Large effects, however, are needed to obtain meaningful effect sizes.

  9. The Reliability of Lumbar Lordosis Measurements Using a Flexible-Rule.

    Science.gov (United States)

    The purpose of this study was to examine the intra-rater and intra-rater reliability of lumbar lordosis measurements taken with a flexible-rule. Two...coefficients (ICC) were used to determine the degree of agreement between measurements. The results suggest that measurements of lumbar lordosis with a

  10. Reliability and validity of the AutoCAD software method in lumbar lordosis measurement.

    Science.gov (United States)

    Letafatkar, Amir; Amirsasan, Ramin; Abdolvahabi, Zahra; Hadadnezhad, Malihe

    2011-12-01

    The aim of this study was to determine the reliability and validity of the AutoCAD software method in lumbar lordosis measurement. Fifty healthy volunteers with a mean age of 23 ± 1.80 years were enrolled. A lumbar lateral radiograph was taken on all participants, and the lordosis was measured according to the Cobb method. Afterward, the lumbar lordosis degree was measured via AutoCAD software and flexible ruler methods. The current study is accomplished in 2 parts: intratester and intertester evaluations of reliability as well as the validity of the flexible ruler and software methods. Based on the intraclass correlation coefficient, AutoCAD's reliability and validity in measuring lumbar lordosis were 0.984 and 0.962, respectively. AutoCAD showed to be a reliable and valid method to measure lordosis. It is suggested that this method may replace those that are costly and involve health risks, such as radiography, in evaluating lumbar lordosis.

  11. Probabilistic risk assessment course documentation. Volume 5. System reliability and analysis techniques Session D - quantification

    International Nuclear Information System (INIS)

    Lofgren, E.V.

    1985-08-01

    This course in System Reliability and Analysis Techniques focuses on the probabilistic quantification of accident sequences and the link between accident sequences and consequences. Other sessions in this series focus on the quantification of system reliability and the development of event trees and fault trees. This course takes the viewpoint that event tree sequences or combinations of system failures and success are available and that Boolean equations for system fault trees have been developed and are available. 93 figs., 11 tabs

  12. Risk and reliability analyses (LURI) and expert judgement techniques

    International Nuclear Information System (INIS)

    Pyy, P.; Pulkkinen, U.

    1998-01-01

    Probabilistic safety analysis (PSA) is currently used as a regulatory licensing tool in risk informed and plant performance based regulation. More often also utility safety improvements are based on PSA calculations as one criterion. PSA attempts to comprehensively identify all important risk contributors, compare them with each other, assess the safety level and suggest improvements based on its findings. The strength of PSA is that it is capable to provide decision makers with numerical estimates of risks. This makes decision making easier than the comparison of purely qualitative results. PSA is the only comprehensive tool that compactly attempts to include all the important risk contributors in its scope. Despite the demonstrated strengths of PSA, there are some features that have reduced its uses. For example, the PSA scope has been limited to the power operation and process internal events (transients and LOCAs). Only lately, areas such as shutdown, external events and severe accidents have been included in PSA models in many countries. Problems related to modelling are, e.g., that rather static fault and event tree models are commonly used in PSA to model dynamic event sequences. Even if a valid model may be generated, there may not be any other data sources to be used than expert judgement. Furthermore, there are a variety of different techniques for human reliability assessment (HRA) giving varying results. In the project Reliability and Risk Analyses (LURI) these limitations and shortcomings have been studied. In the decision making area, case studies on the application of decision analysis and a doctoral thesis have been published. Further, practical aid has been given to utilities and regulatory decision making. Model uncertainty effect on PSA results has been demonstrated by two case studies. Human reliability has been studied both in the integrated safety analysis study and in the study of maintenance originated NPP component faults based on the

  13. A test chip for automatic reliability measurements of interconnect vias

    NARCIS (Netherlands)

    Lippe, K.; Hasper, A.; Elfrink, G.W.; Niehof, J.; Kerkhoff, Hans G.

    1992-01-01

    A test circuit for electromigration reliability measurements was designed and tested. The device under test (DUT) is a via-hole chain. The test circuit permits simultaneous measurements of a number of DUTs, and a fatal error of one DUT does not influence the measurement results of the other DUTs.

  14. Using LISREL to Evaluate Measurement Models and Scale Reliability.

    Science.gov (United States)

    Fleishman, John; Benson, Jeri

    1987-01-01

    LISREL program was used to examine measurement model assumptions and to assess reliability of Coopersmith Self-Esteem Inventory for Children, Form B. Data on 722 third-sixth graders from over 70 schools in large urban school district were used. LISREL program assessed (1) nature of basic measurement model for scale, (2) scale invariance across…

  15. Tactile acuity charts: a reliable measure of spatial acuity.

    Directory of Open Access Journals (Sweden)

    Patrick Bruns

    Full Text Available For assessing tactile spatial resolution it has recently been recommended to use tactile acuity charts which follow the design principles of the Snellen letter charts for visual acuity and involve active touch. However, it is currently unknown whether acuity thresholds obtained with this newly developed psychophysical procedure are in accordance with established measures of tactile acuity that involve passive contact with fixed duration and control of contact force. Here we directly compared tactile acuity thresholds obtained with the acuity charts to traditional two-point and grating orientation thresholds in a group of young healthy adults. For this purpose, two types of charts, using either Braille-like dot patterns or embossed Landolt rings with different orientations, were adapted from previous studies. Measurements with the two types of charts were equivalent, but generally more reliable with the dot pattern chart. A comparison with the two-point and grating orientation task data showed that the test-retest reliability of the acuity chart measurements after one week was superior to that of the passive methods. Individual thresholds obtained with the acuity charts agreed reasonably with the grating orientation threshold, but less so with the two-point threshold that yielded relatively distinct acuity estimates compared to the other methods. This potentially considerable amount of mismatch between different measures of tactile acuity suggests that tactile spatial resolution is a complex entity that should ideally be measured with different methods in parallel. The simple test procedure and high reliability of the acuity charts makes them a promising complement and alternative to the traditional two-point and grating orientation thresholds.

  16. Reliability of surface EMG measurements from the suprahyoid muscle complex

    DEFF Research Database (Denmark)

    Kothari, Mohit; Stubbs, Peter William; Pedersen, Asger Roer

    2017-01-01

    of using the suprahyoid muscle complex (SMC) using surface electromyography (sEMG) to assess changes to neural pathways by determining the reliability of measurements in healthy participants over days. Methods: Seventeen healthy participants were recruited. Measurements were performed twice with one week...... on stimulus type/intensity) had significantly different MEP values between day 1 and day 2 for single pulse and paired pulse TMS. A large stimulus artefact resulted in MEP responses that could not be assessed in four participants. Conclusions: The assessment of the SMC using sEMG following TMS was poorly...... reliable for ≈50% of participants. Although using sEMG to assess swallowing musculature function is easier to perform clinically and more comfortable to patients than invasive measures, as the measurement of muscle activity using TMS is unreliable, the use of sEMG for this muscle group is not recommended...

  17. Recommendations for certification or measurement of reliability for reliable digital archival repositories with emphasis on access

    Directory of Open Access Journals (Sweden)

    Paula Regina Ventura Amorim Gonçalez

    2017-04-01

    Full Text Available Introduction: Considering the guidelines of ISO 16363: 2012 (Space data and information transfer systems -- Audit and certification of trustworthy digital repositories and the text of CONARQ Resolution 39 for certification of Reliable Digital Archival Repository (RDC-Arq, verify the technical recommendations should be used as the basis for a digital archival repository to be considered reliable. Objective: Identify requirements for the creation of Reliable Digital Archival Repositories with emphasis on access to information from the ISO 16363: 2012 and CONARQ Resolution 39. Methodology: For the development of the study, the methodology consisted of an exploratory, descriptive and documentary theoretical investigation, since it is based on ISO 16363: 2012 and CONARQ Resolution 39. From the perspective of the problem approach, the study is qualitative and quantitative, since the data were collected, tabulated, and analyzed from the interpretation of their contents. Results: We presented a set of Checklist Recommendations for reliability measurement and/or certification for RDC-Arq with a clipping focused on the identification of requirements with emphasis on access to information is presented. Conclusions: The right to information as well as access to reliable information is a premise for Digital Archival Repositories, so the set of recommendations is directed to archivists who work in Digital Repositories and wish to verify the requirements necessary to evaluate the reliability of the Digital Repository or still guide the information professional in collecting requirements for repository reliability certification.

  18. A computational technique to measure fracture callus in radiographs.

    Science.gov (United States)

    Lujan, Trevor J; Madey, Steven M; Fitzpatrick, Dan C; Byrd, Gregory D; Sanderson, Jason M; Bottlang, Michael

    2010-03-03

    Callus formation occurs in the presence of secondary bone healing and has relevance to the fracture's mechanical environment. An objective image processing algorithm was developed to standardize the quantitative measurement of periosteal callus area in plain radiographs of long bone fractures. Algorithm accuracy and sensitivity were evaluated using surrogate models. For algorithm validation, callus formation on clinical radiographs was measured manually by orthopaedic surgeons and compared to non-clinicians using the algorithm. The algorithm measured the projected area of surrogate calluses with less than 5% error. However, error will increase when analyzing very small areas of callus and when using radiographs with low image resolution (i.e. 100 pixels per inch). The callus size extracted by the algorithm correlated well to the callus size outlined by the surgeons (R2=0.94, p<0.001). Furthermore, compared to clinician results, the algorithm yielded results with five times less inter-observer variance. This computational technique provides a reliable and efficient method to quantify secondary bone healing response. Copyright 2009 Elsevier Ltd. All rights reserved.

  19. Semiconductor measurement technology: reliability technology for cardiac pacemakers 2: a workshop report, 1976

    International Nuclear Information System (INIS)

    Schafft, H.A.

    1977-01-01

    Summaries are presented of 12 invited talks on the following topics: the procurement and assurance of high reliability electronic parts, leak rate and moisture measurements, pacemaker batteries, and pacemaker leads. The workshop, second in a series, was held in response to strong interest expressed by the pacemaker community to address technical questions relevant to the enhancement and assurance of cardiac pacemaker reliability. Discussed at the workshop were a process validation wafer concept for assuring process uniformity in device chips; screen tests for assuring reliable electronic parts; reliability prediction; reliability comparison of semiconductor technologies; mechanisms of short-circuiting dendritic growths; details of helium and radioisotope leak test methods; a study to correlate package leak rates, as measured with test gasses, and actual moisture infusion; battery life prediction; microcalorimetric measurements to nondestructively evaluate batteries for pacemakers; and an engineer's and a physician's view of the present status of pacemaker leads. References are included with most of the reports

  20. A method of bias correction for maximal reliability with dichotomous measures.

    Science.gov (United States)

    Penev, Spiridon; Raykov, Tenko

    2010-02-01

    This paper is concerned with the reliability of weighted combinations of a given set of dichotomous measures. Maximal reliability for such measures has been discussed in the past, but the pertinent estimator exhibits a considerable bias and mean squared error for moderate sample sizes. We examine this bias, propose a procedure for bias correction, and develop a more accurate asymptotic confidence interval for the resulting estimator. In most empirically relevant cases, the bias correction and mean squared error correction can be performed simultaneously. We propose an approximate (asymptotic) confidence interval for the maximal reliability coefficient, discuss the implementation of this estimator, and investigate the mean squared error of the associated asymptotic approximation. We illustrate the proposed methods using a numerical example.

  1. Measuring older adults' sedentary time: reliability, validity, and responsiveness.

    Science.gov (United States)

    Gardiner, Paul A; Clark, Bronwyn K; Healy, Genevieve N; Eakin, Elizabeth G; Winkler, Elisabeth A H; Owen, Neville

    2011-11-01

    With evidence that prolonged sitting has deleterious health consequences, decreasing sedentary time is a potentially important preventive health target. High-quality measures, particularly for use with older adults, who are the most sedentary population group, are needed to evaluate the effect of sedentary behavior interventions. We examined the reliability, validity, and responsiveness to change of a self-report sedentary behavior questionnaire that assessed time spent in behaviors common among older adults: watching television, computer use, reading, socializing, transport and hobbies, and a summary measure (total sedentary time). In the context of a sedentary behavior intervention, nonworking older adults (n = 48, age = 73 ± 8 yr (mean ± SD)) completed the questionnaire on three occasions during a 2-wk period (7 d between administrations) and wore an accelerometer (ActiGraph model GT1M) for two periods of 6 d. Test-retest reliability (for the individual items and the summary measure) and validity (self-reported total sedentary time compared with accelerometer-derived sedentary time) were assessed during the 1-wk preintervention period, using Spearman (ρ) correlations and 95% confidence intervals (CI). Responsiveness to change after the intervention was assessed using the responsiveness statistic (RS). Test-retest reliability was excellent for television viewing time (ρ (95% CI) = 0.78 (0.63-0.89)), computer use (ρ (95% CI) = 0.90 (0.83-0.94)), and reading (ρ (95% CI) = 0.77 (0.62-0.86)); acceptable for hobbies (ρ (95% CI) = 0.61 (0.39-0.76)); and poor for socializing and transport (ρ < 0.45). Total sedentary time had acceptable test-retest reliability (ρ (95% CI) = 0.52 (0.27-0.70)) and validity (ρ (95% CI) = 0.30 (0.02-0.54)). Self-report total sedentary time was similarly responsive to change (RS = 0.47) as accelerometer-derived sedentary time (RS = 0.39). The summary measure of total sedentary time has good repeatability and modest validity and is

  2. Reliability analysis techniques for the design engineer

    International Nuclear Information System (INIS)

    Corran, E.R.; Witt, H.H.

    1980-01-01

    A fault tree analysis package is described that eliminates most of the housekeeping tasks involved in proceeding from the initial construction of a fault tree to the final stage of presenting a reliability analysis in a safety report. It is suitable for designers with relatively little training in reliability analysis and computer operation. Users can rapidly investigate the reliability implications of various options at the design stage, and evolve a system which meets specified reliability objectives. Later independent review is thus unlikely to reveal major shortcomings necessitating modification and projects delays. The package operates interactively allowing the user to concentrate on the creative task of developing the system fault tree, which may be modified and displayed graphically. For preliminary analysis system data can be derived automatically from a generic data bank. As the analysis procedes improved estimates of critical failure rates and test and maintenance schedules can be inserted. The computations are standard, - identification of minimal cut-sets, estimation of reliability parameters, and ranking of the effect of the individual component failure modes and system failure modes on these parameters. The user can vary the fault trees and data on-line, and print selected data for preferred systems in a form suitable for inclusion in safety reports. A case history is given - that of HIFAR containment isolation system. (author)

  3. Test-Retest Reliability of Dual-Task Outcome Measures in People With Parkinson Disease

    NARCIS (Netherlands)

    Strouwen, C.; Molenaar, E.A.; Keus, S.H.; Munks, L.; Bloem, B.R.; Nieuwboer, A.

    2016-01-01

    BACKGROUND: Dual-task (DT) training is gaining ground as a physical therapy intervention in people with Parkinson disease (PD). Future studies evaluating the effect of such interventions need reliable outcome measures. To date, the test-retest reliability of DT measures in patients with PD remains

  4. Design reliability engineering

    International Nuclear Information System (INIS)

    Buden, D.; Hunt, R.N.M.

    1989-01-01

    Improved design techniques are needed to achieve high reliability at minimum cost. This is especially true of space systems where lifetimes of many years without maintenance are needed and severe mass limitations exist. Reliability must be designed into these systems from the start. Techniques are now being explored to structure a formal design process that will be more complete and less expensive. The intent is to integrate the best features of design, reliability analysis, and expert systems to design highly reliable systems to meet stressing needs. Taken into account are the large uncertainties that exist in materials, design models, and fabrication techniques. Expert systems are a convenient method to integrate into the design process a complete definition of all elements that should be considered and an opportunity to integrate the design process with reliability, safety, test engineering, maintenance and operator training. 1 fig

  5. Reliability of measuring abductor hallucis muscle parameters using two different diagnostic ultrasound machines

    Directory of Open Access Journals (Sweden)

    Cameron Alyse FM

    2009-11-01

    Full Text Available Abstract Background Diagnostic ultrasound provides a method of analysing soft tissue structures of the musculoskeletal system effectively and reliably. The aim of this study was to evaluate within and between session reliability of measuring muscle dorso-plantar thickness, medio-lateral length and cross-sectional area, of the abductor hallucis muscle using two different ultrasound machines, a higher end Philips HD11 Ultrasound machine and clinically orientated Chison 8300 Deluxe Digital Portable Ultrasound System. Methods The abductor hallucis muscle of both the left and right feet of thirty asymptomatic participants was imaged and then measured using both ultrasound machines. Interclass correlation coefficients (ICC with 95% confidence intervals (CI were used to calculate both within and between session intra-tester reliability. Standard error of the measurement (SEM calculations were undertaken to assess difference between the actual measured score across trials and the smallest real difference (SRD was calculated from the SEM to indicate the degree of change that would exceed the expected trial to trial variability. Results The ICCs, SEM and SRD for dorso-plantar thickness and medial-lateral length were shown to have excellent to high within and between-session reliability for both ultrasound machines. The between-session reliability indices for cross-sectional area were acceptable for both ultrasound machines. Conclusion The results of the current study suggest that regardless of the type ultrasound machine, intra-tester reliability for the measurement the abductor hallucis muscle parameters is very high.

  6. Travel Time Reliability in Indiana

    OpenAIRE

    Martchouk, Maria; Mannering, Fred L.; Singh, Lakhwinder

    2010-01-01

    Travel time and travel time reliability are important performance measures for assessing traffic condition and extent of congestion on a roadway. This study first uses a floating car technique to assess travel time and travel time reliability on a number of Indiana highways. Then the study goes on to describe the use of Bluetooth technology to collect real travel time data on a freeway and applies it to obtain two weeks of data on Interstate 69 in Indianapolis. An autoregressive model, estima...

  7. Thickness measurement for the different metals by using Cs-137 gamma source with gamma transmission technique

    International Nuclear Information System (INIS)

    Bueyuek, B.; Tugrul, B.

    2009-01-01

    The purpose of this study is an experimental analysis of thickness measurement for various metals with the gamma transmission technique using Cs-137 as the radioisotope source. Lead, steel, brass, and aluminum, which are frequently used metals in industry, were chosen for the experiments. As the radioisotope source Cs-137 was preferred for the study since it has long half-life, it is mono energetic, and it penetrates the metals that were studied. Experiments were observed in the constant experimental geometry. Calibration curves for the four metal samples were plotted using the obtained results. To test the plotted calibration curves, counts for determining thickness measurement were collected for each sample and the obtained relative count values were used in conjunction with the plotted calibration curves for each sample to determine its thickness. The thicknesses of the samples have been measured with a micrometer and the results were comparatively analyzed with the measurement results obtained by the gamma transmission technique. The results of the analyses revealed that the thickness measurement values obtained with the gamma transmission technique and the thickness measurement values obtained with the conventional technique significantly converge to each other and the difference between the two values is at an acceptable level. Therefore the reliability of thickness measurements with the gamma transmission technique and the resulting calibration curves have been demonstrated.

  8. Magnetic field measurements and mapping techniques

    CERN Multimedia

    CERN. Geneva

    2003-01-01

    These lectures will present an overview of the most common techniques used for the measurement of magnetic field in accelerator magnets. The formalism for a harmonic description of the magnetic field will be presented, including a discussion of harmonics allowed under various types of symmetries in the magnet. The harmonic coil technique for measurement of field harmonics will be covered in depth. Using examples from recent projects, magnetic measurements will be shown to be a powerful tool for monitoring magnet production. Measurements of magnetic axis using extensions of the harmonic coil technique, as well as other techniques, such as the colloidal cell and stretched wire, will be covered. Topics of interest in superconducting magnets, such as time decay and snapback, requiring relatively fast measurements of the harmonics, will also be described.

  9. Radioisotope Sample Measurement Techniques in Medicine and Biology. Proceedings of the Symposium on Radioisotope Sample Measurement Techniques

    International Nuclear Information System (INIS)

    1965-01-01

    The medical and biological applications of radioisotopes depend on two basically different types of measurements, those on living subjects in vivo and those on samples in vitro. The International Atomic Energy Agency has in the past held several meetings on in vivo measurement techniques, notably whole-body counting and radioisotope scanning. The present volume contains the Proceedings of the first Symposium the Agency has organized to discuss the various aspects of techniques for sample measurement in vitro. The range of these sample measurement techniques is very wide. The sample may weigh a few milligrams or several hundred grams, and may be in the gaseous, liquid or solid state. Its radioactive content may consist of a single, known radioisotope or several unknown ones. The concentration of radioactivity may be low, medium or high. The measurements may be made manually or automatically and any one of the many radiation detectors now available may be used. The 53 papers presented at the Symposium illustrate the great variety of methods now in use for radioactive- sample measurements. The first topic discussed is gamma-ray spectrometry, which finds an increasing number of applications in sample measurements. Other sections of the Proceedings deal with: the use of computers in gamma-ray spectrometry and multiple tracer techniques; recent developments in activation analysis where both gamma-ray spectrometry and computing techniques are applied; thin-layer and paper radio chromatographic techniques for use with low energy beta-ray emitters; various aspects of liquid scintillation counting techniques in the measurement of alpha- and beta-ray emitters, including chemical and colour quenching; autoradiographic techniques; calibration of equipment; and standardization of radioisotopes. Finally, some applications of solid-state detectors are presented; this section may be regarded as a preview of important future developments. The meeting was attended by 203 participants

  10. Systems reliability/structural reliability

    International Nuclear Information System (INIS)

    Green, A.E.

    1980-01-01

    The question of reliability technology using quantified techniques is considered for systems and structures. Systems reliability analysis has progressed to a viable and proven methodology whereas this has yet to be fully achieved for large scale structures. Structural loading variants over the half-time of the plant are considered to be more difficult to analyse than for systems, even though a relatively crude model may be a necessary starting point. Various reliability characteristics and environmental conditions are considered which enter this problem. The rare event situation is briefly mentioned together with aspects of proof testing and normal and upset loading conditions. (orig.)

  11. Reliability of in-Shoe Plantar Pressure Measurements in Rheumatoid Arthritis Patients

    Science.gov (United States)

    Vidmar, Gaj; Novak, Primoz

    2009-01-01

    Plantar pressures measurement is a frequently used method in rehabilitation and related research. Metric characteristics of the F-Scan system have been assessed from different standpoints and in different patients, but not its reliability in rheumatoid arthritis patients. Therefore, our objective was to assess reliability of the F-Scan plantar…

  12. Development of a morphology-based modeling technique for tracking solid-body displacements: examining the reliability of a potential MRI-only approach for joint kinematics assessment

    International Nuclear Information System (INIS)

    Mahato, Niladri K.; Montuelle, Stephane; Cotton, John; Williams, Susan; Thomas, James; Clark, Brian

    2016-01-01

    Single or biplanar video radiography and Roentgen stereophotogrammetry (RSA) techniques used for the assessment of in-vivo joint kinematics involves application of ionizing radiation, which is a limitation for clinical research involving human subjects. To overcome this limitation, our long-term goal is to develop a magnetic resonance imaging (MRI)-only, three dimensional (3-D) modeling technique that permits dynamic imaging of joint motion in humans. Here, we present our initial findings, as well as reliability data, for an MRI-only protocol and modeling technique. We developed a morphology-based motion-analysis technique that uses MRI of custom-built solid-body objects to animate and quantify experimental displacements between them. The technique involved four major steps. First, the imaging volume was calibrated using a custom-built grid. Second, 3-D models were segmented from axial scans of two custom-built solid-body cubes. Third, these cubes were positioned at pre-determined relative displacements (translation and rotation) in the magnetic resonance coil and scanned with a T 1 and a fast contrast-enhanced pulse sequences. The digital imaging and communications in medicine (DICOM) images were then processed for animation. The fourth step involved importing these processed images into an animation software, where they were displayed as background scenes. In the same step, 3-D models of the cubes were imported into the animation software, where the user manipulated the models to match their outlines in the scene (rotoscoping) and registered the models into an anatomical joint system. Measurements of displacements obtained from two different rotoscoping sessions were tested for reliability using coefficient of variations (CV), intraclass correlation coefficients (ICC), Bland-Altman plots, and Limits of Agreement analyses. Between-session reliability was high for both the T 1 and the contrast-enhanced sequences. Specifically, the average CVs for translation were 4

  13. Development of a morphology-based modeling technique for tracking solid-body displacements: examining the reliability of a potential MRI-only approach for joint kinematics assessment.

    Science.gov (United States)

    Mahato, Niladri K; Montuelle, Stephane; Cotton, John; Williams, Susan; Thomas, James; Clark, Brian

    2016-05-18

    Single or biplanar video radiography and Roentgen stereophotogrammetry (RSA) techniques used for the assessment of in-vivo joint kinematics involves application of ionizing radiation, which is a limitation for clinical research involving human subjects. To overcome this limitation, our long-term goal is to develop a magnetic resonance imaging (MRI)-only, three dimensional (3-D) modeling technique that permits dynamic imaging of joint motion in humans. Here, we present our initial findings, as well as reliability data, for an MRI-only protocol and modeling technique. We developed a morphology-based motion-analysis technique that uses MRI of custom-built solid-body objects to animate and quantify experimental displacements between them. The technique involved four major steps. First, the imaging volume was calibrated using a custom-built grid. Second, 3-D models were segmented from axial scans of two custom-built solid-body cubes. Third, these cubes were positioned at pre-determined relative displacements (translation and rotation) in the magnetic resonance coil and scanned with a T1 and a fast contrast-enhanced pulse sequences. The digital imaging and communications in medicine (DICOM) images were then processed for animation. The fourth step involved importing these processed images into an animation software, where they were displayed as background scenes. In the same step, 3-D models of the cubes were imported into the animation software, where the user manipulated the models to match their outlines in the scene (rotoscoping) and registered the models into an anatomical joint system. Measurements of displacements obtained from two different rotoscoping sessions were tested for reliability using coefficient of variations (CV), intraclass correlation coefficients (ICC), Bland-Altman plots, and Limits of Agreement analyses. Between-session reliability was high for both the T1 and the contrast-enhanced sequences. Specifically, the average CVs for translation were 4

  14. Ensuring Structural Integrity through Reliable Residual Stress Measurement: From Crystals to Crankshafts

    International Nuclear Information System (INIS)

    Edwards, Lyndon

    2005-01-01

    Full text: The determination of accurate, reliable stresses is critical to many fields of engineering and, in particular, the structural integrity and hence, safety, of many systems. Neutron stress measurement is a non-destructive technique that uniquely provides insights into stress fields deep within components and structures. As such, it has become an increasingly important tool within the engineering community leading to improved manufacturing processes to reduce stress and distortion as well as to the definition of more precise structural integrity lifting procedures. This talk describes the current state of the art and identifies the key opportunities for improved structural integrity provided by the 2nd generation dedicated engineering stress diffractometers currently being designed and commissioned world-wide. Examples are provided covering a range of industrially relevant problems from the fields. (author)

  15. Inter- and intra-observer reliability of masking in plantar pressure measurement analysis.

    Science.gov (United States)

    Deschamps, K; Birch, I; Mc Innes, J; Desloovere, K; Matricali, G A

    2009-10-01

    Plantar pressure measurement is an important tool in gait analysis. Manual placement of small masks (masking) is increasingly used to calculate plantar pressure characteristics. Little is known concerning the reliability of manual masking. The aim of this study was to determine the reliability of masking on 2D plantar pressure footprints, in a population with forefoot deformity (i.e. hallux valgus). Using a random repeated-measure design, four observers identified the third metatarsal head on a peak-pressure barefoot footprint, using a small mask. Subsequently, the location of all five metatarsal heads was identified, using the same size of masks and the same protocol. The 2D positional variation of the masks and the peak pressure (PP) and pressure time integral (PTI) values of each mask were calculated. For single-masking the lowest inter-observer reliability was found for the distal-proximal direction, causing a clear, adverse impact on the reliability of the pressure characteristics (PP and PTI). In the medial-lateral direction the inter-observer reliability could be scored as high. Intra-observer reliability was better and could be scored as high or good for both directions, with a correlated improved reliability of the pressure characteristics. Reliability of multi-masking showed a similar pattern, but overall values tended to be lower. Therefore, small sized masking in order to define pressure characteristics in the forefoot should be done with care.

  16. Reliability of routine clinical measurements of neonatal circumferences and research measurements of neonatal skinfold thicknesses: findings from the Born in Bradford study

    Science.gov (United States)

    West, Jane; Manchester, Ben; Wright, John; Lawlor, Debbie A; Waiblinger, Dagmar

    2011-01-01

    Summary West J, Manchester B, Wright J, Lawlor DA, Waiblinger D. Reliability of routine clinical measurements of neonatal circumferences and research measurements of neonatal skinfold thicknesses: findings from the Born in Bradford study. Paediatric and Perinatal Epidemiology 2011. Assessing neonatal size reliably is important for research and clinical practice. The aim of this study was to examine the reliability of routine clinical measurements of neonatal circumferences and of skinfold thicknesses assessed for research purposes. All measurements were undertaken on the same population of neonates born in a large maternity unit in Bradford, UK. Technical error of measurement (TEM), relative TEM and the coefficient of reliability are reported. Intra-observer TEMs for routine circumference measurements were all below 0.4 cm and were generally within ±2-times the mean. Inter-observer TEM ranged from 0.20 to 0.36 cm for head circumference, 0.19 to 0.39 cm for mid upper arm circumference and from 0.39 to 0.77 cm for abdominal circumference. Intra and inter-observer TEM for triceps skinfold thickness ranged from 0.22 to 0.35 mm and 0.15 to 0.54 mm, respectively. Subscapular skinfold thickness TEM values were 0.14 to 0.25 mm for intra-observer measurements and 0.17 to 0.63 mm for inter-observer measurements. Relative TEM values for routine circumferences were all below 4.00% but varied between 2.88% and 14.23% for research skinfold measurements. Reliability was mostly between 80% and 99% for routine circumference measurements and ≥70% for most research skinfold measurements. Routine clinical measurements of neonatal circumferences are reliably assessed in Bradford. Assessing skinfolds in neonates has variable reliability, but on the whole is good. The greater intra-observer, compared with inter-observer, reliability for both sets of measurements highlights the importance of having a minimal number of assessors whenever possible. PMID:21281329

  17. Reliability and short-term intra-individual variability of telomere length measurement using monochrome multiplexing quantitative PCR.

    Directory of Open Access Journals (Sweden)

    Sangmi Kim

    Full Text Available Studies examining the association between telomere length and cancer risk have often relied on measurement of telomere length from a single blood draw using a real-time PCR technique. We examined the reliability of telomere length measurement using sequential samples collected over a 9-month period.Relative telomere length in peripheral blood was estimated using a single tube monochrome multiplex quantitative PCR assay in blood DNA samples from 27 non-pregnant adult women (aged 35 to 74 years collected in 7 visits over a 9-month period. A linear mixed model was used to estimate the components of variance for telomere length measurements attributed to variation among women and variation between time points within women. Mean telomere length measurement at any single visit was not significantly different from the average of 7 visits. Plates had a significant systematic influence on telomere length measurements, although measurements between different plates were highly correlated. After controlling for plate effects, 64% of the remaining variance was estimated to be accounted for by variance due to subject. Variance explained by time of visit within a subject was minor, contributing 5% of the remaining variance.Our data demonstrate good short-term reliability of telomere length measurement using blood from a single draw. However, the existence of technical variability, particularly plate effects, reinforces the need for technical replicates and balancing of case and control samples across plates.

  18. Errors during MRT measurements of the left ventricular volume using a multi-slice technique

    International Nuclear Information System (INIS)

    Pitton, M.B.; Just, M.; Grebe, P.; Kreitner, K.F.; Erbel, R.; Thelen, M.

    1992-01-01

    A multi-slice technique for MRT measurements of the left ventricular volume is much faster than the use of single-slice methods and is therefore better tolerated, leaving time for additional measurements. The end-diastolic left ventricular volume can be reliably measured by this method (123.3±13.5 ml vs. 124.1±ml). The end-systolic volume is consistently overestimated by 23.7±18,3% compared with the reference value obtained by single slice measurements (47.9±8.9 ml vs 39.1±7.9 ml). Correspondingly, stroke volume and ejection fraction is underestimated on average by 10.6±9.7% and 10.6±7.6% respectively). (orig.) [de

  19. The gothic arch: a reliable measurement for developmental dysplasia of the hip.

    Science.gov (United States)

    Herickhoff, Paul K; O'Brien, Megan K; Dolan, Lori A; Morcuende, Jose A; Peterson, Jonathan B; Weinstein, Stuart L

    2013-01-01

    The "Gothic Arch" is a radio-graphic finding on AP pelvis x-rays postulated to be predictive of hip osteoarthritis. The purpose of this study was to determine the reliability of measurement of the Gothic Arch in patients with no known hip pathology and patients with unilateral developmental dysplasia of the hip (DDH). After obtaining IRB approval, nine skeletally mature patients (18 hips) with no known hip pathology were selected to serve as the control group. The AP pelvis x-rays at skeletal maturity of eight patients (16 hips) with unilateral DDH treated with closed reduction and casting comprised the comparison group. A digitizing program was designed to measure the Gothic Arch based on landmarks identified by the user. Two pediatric orthopaedic surgeons and two orthopaedic residents completed the program on two separate occasions. Intra-and interobserver reliability were determined using intraclass cor-relation coefficients (ICC) for continuous variables. Both the unilateral DDH group and the control group demonstrated excellent inter- and intraobserver reliability (ICC >0.70) for base, height, area, and orientation of the Gothic Arch, but poor reliability (ICC Gothic Arch can be reliably measured on AP pelvis x-rays of patients with normal and dysplastic hips. III, Diagnostic study. See the Guidelines for Authors for a complete description of levels of evidence.

  20. Validity and reliability of food security measures.

    Science.gov (United States)

    Cafiero, Carlo; Melgar-Quiñonez, Hugo R; Ballard, Terri J; Kepple, Anne W

    2014-12-01

    This paper reviews some of the existing food security indicators, discussing the validity of the underlying concept and the expected reliability of measures under reasonably feasible conditions. The main objective of the paper is to raise awareness on existing trade-offs between different qualities of possible food security measurement tools that must be taken into account when such tools are proposed for practical application, especially for use within an international monitoring framework. The hope is to provide a timely, useful contribution to the process leading to the definition of a food security goal and the associated monitoring framework within the post-2015 Development Agenda. © 2014 New York Academy of Sciences.

  1. Insightful practice: a reliable measure for medical revalidation

    Science.gov (United States)

    Guthrie, Bruce; Sullivan, Frank M; Mercer, Stewart W; Russell, Andrew; Bruce, David A

    2012-01-01

    Background Medical revalidation decisions need to be reliable if they are to reassure on the quality and safety of professional practice. This study tested an innovative method in which general practitioners (GPs) were assessed on their reflection and response to a set of externally specified feedback. Setting and participants 60 GPs and 12 GP appraisers in the Tayside region of Scotland, UK. Methods A feedback dataset was specified as (1) GP-specific data collected by GPs themselves (patient and colleague opinion; open book self-evaluated knowledge test; complaints) and (2) Externally collected practice-level data provided to GPs (clinical quality and prescribing safety). GPs' perceptions of whether the feedback covered UK General Medical Council specified attributes of a ‘good doctor’ were examined using a mapping exercise. GPs' professionalism was examined in terms of appraiser assessment of GPs' level of insightful practice, defined as: engagement with, insight into and appropriate action on feedback data. The reliability of assessment of insightful practice and subsequent recommendations on GPs' revalidation by face-to-face and anonymous assessors were investigated using Generalisability G-theory. Main outcome measures Coverage of General Medical Council attributes by specified feedback and reliability of assessor recommendations on doctors' suitability for revalidation. Results Face-to-face assessment proved unreliable. Anonymous global assessment by three appraisers of insightful practice was highly reliable (G=0.85), as were revalidation decisions using four anonymous assessors (G=0.83). Conclusions Unlike face-to-face appraisal, anonymous assessment of insightful practice offers a valid and reliable method to decide GP revalidation. Further validity studies are needed. PMID:22653078

  2. Reliability of quantitative echocardiography in adult sheep and goats

    Directory of Open Access Journals (Sweden)

    Hallowell Gayle D

    2012-09-01

    Full Text Available Abstract Background Echocardiography is a non-invasive method for assessment of the ovine and caprine heart. Complete reference ranges for cardiac dimensions and time indices for both species are not currently available and reliability of these measurements has not been evaluated. The objectives for this study are to report reliability, normal cardiac dimensions and time indices in a large group of adult sheep and goats. Fifty-one adult sheep and forty adult goats were recruited. Full echocardiographic examinations were performed in the standing unsedated animal. All animals underwent echocardiography four times in a 72-hour period. Echocardiography was performed three times by one author and once by another. Images were stored and measured offline. Technique and measurement repeatability and reproducibility and any differences due to animal or day were evaluated. Reference ranges (mean ± 2 standard deviations were calculated for both species. Results Majority of the images obtained were of good to excellent quality. Image acquisition was straightforward with 5.4% of animals demonstrating a small scanning window. Reliability was excellent for majority of dimensions and time indices. There was less variation in repeatability when compared with reproducibility and differences were greater for technique than for measurements. Dimensions that were less reliable included those for right ventricular diameter and left ventricular free wall. There were many differences in cardiac dimensions between sheep and goats. Conclusions This study has demonstrated that specific reference ranges are required for these two species. Repeatability and reproducibility were excellent for the majority of cardiac dimensions and time indices suggesting that this technique is reliable and valuable for examination of clinical cases over time and for longitudinal research studies.

  3. The application of two recently developed human reliability techniques to cognitive error analysis

    International Nuclear Information System (INIS)

    Gall, W.

    1990-01-01

    Cognitive error can lead to catastrophic consequences for manned systems, including those whose design renders them immune to the effects of physical slips made by operators. Four such events, pressurized water and boiling water reactor accidents which occurred recently, were analysed. The analysis identifies the factors which contributed to the errors and suggests practical strategies for error recovery or prevention. Two types of analysis were conducted: an unstructured analysis based on the analyst's knowledge of psychological theory, and a structured analysis using two recently-developed human reliability analysis techniques. In general, the structured techniques required less effort to produce results and these were comparable to those of the unstructured analysis. (author)

  4. Application of expert elicitation techniques in human reliability, assessment

    International Nuclear Information System (INIS)

    Sanyasi Rao, V.V.S.; Saraf, R.K.; Ghosh, A.K.; Kushwaha, H.S.

    2006-01-01

    Expert elicitation techniques are being used, in the area of technological forecasting, in estimating data needed for analysis when it is either difficult to arrive at the data by experimental means or when it is quite involved to plan and conduct the experiment. In this study, expert elicitation techniques are applied to the evaluation of the frequencies of the various accident sequences that can result from the initiating event (IE) 'High Pressure Process Water (HPPW) system failure' in typical Indian Pressurised Heavy Water Reactor (IPHWR) of the older generation. The Operating Procedure under Emergency Conditions (OPEC) for this IE involves human actions according to a pre-defined procedure. The Human Error Probabilities for all these human actions are obtained using expert elicitation techniques. These techniques aim at eliciting the opinion of the experts in the area of interest with regard to the issue in question. The uncertainty is analysed by employing the measure of dissonance and the most probable range of human error probabilities are arrived at by maximizing this measure. These values are combined using the same procedures mentioned above to yield a distribution representing the uncertainty associated with the predictions. (author)

  5. Efficiency criteria for high reliability measured system structures

    International Nuclear Information System (INIS)

    Sal'nikov, N.L.

    2012-01-01

    The procedures of structural redundancy are usually used to develop high reliability measured systems. To estimate efficiency of such structures the criteria to compare different systems has been developed. So it is possible to develop more exact system by inspection of redundant system data unit stochastic characteristics in accordance with the developed criteria [ru

  6. Reliability and Validity of Ultrasound Cross Sectional Area Measurements for Long-Duration Spaceflight

    Science.gov (United States)

    Scott, Jessica M.; Martin, David S.; Cunningham, David; Matz, Timothy; Caine, Timothy; Hackney, Kyle J.; Arzeno, Natalia; Ploutz-Snyder, Lori

    2010-01-01

    Limb muscle atrophy and the accompanying decline in function can adversely affect the performance of astronauts during mission-related activities and upon re-ambulation in a gravitational environment. Previous characterization of space flight-induced muscle atrophy has been performed using pre and post flight magnetic resonance imaging (MRI). In addition to being costly and time consuming, MRI is an impractical methodology for assessing in-flight changes in muscle size. Given the mobility of ultrasound (US) equipment, it may be more feasible to evaluate changes in muscle size using this technique. PURPOSE: To examine the reliability and validity of using a customized template to acquire panoramic ultrasound (US) images for determining quadriceps and gastrocnemius anatomical cross sectional area (CSA). METHODS: Vastus lateralis (VL), rectus femoris (RF), medial gastrocnemius (MG), and lateral gastrocnemius (LG) CSA were assessed in 10 healthy individuals (36+/-2 yrs) using US and MRI. Panoramic US images were acquired by 2 sonographers using a customized template placed on the thigh and calf and analyzed by the same 2 sonographers (CX50 Philips). MRI images of the leg were acquired while subjects were supine in a 1.5T scanner (Signa Horizon LX, General Electric) and were analyzed by 3 trained investigators. The average of the 2 US and 3 MRI values were used for validity analysis. RESULTS: High inter-experimenter reliability was found for both the US template and MRI analysis as coefficients of variation across muscles ranged from 2.4 to 4.1% and 2.8 to 3.8%, respectively. Significant correlations were found between US and MRI CSA measures (VL, r = 0.85; RF, r = 0.60; MG, r = 0.86; LG, r = 0.73; p reliable measures of leg muscle CSA, and thus could be used to characterize changes in muscle CSA both in flight and on the ground.

  7. Reliability generalization of the Multigroup Ethnic Identity Measure-Revised (MEIM-R).

    Science.gov (United States)

    Herrington, Hayley M; Smith, Timothy B; Feinauer, Erika; Griner, Derek

    2016-10-01

    [Correction Notice: An Erratum for this article was reported in Vol 63(5) of Journal of Counseling Psychology (see record 2016-33161-001). The name of author Erika Feinauer was misspelled as Erika Feinhauer. All versions of this article have been corrected.] Individuals' strength of ethnic identity has been linked with multiple positive indicators, including academic achievement and overall psychological well-being. The measure researchers use most often to assess ethnic identity, the Multigroup Ethnic Identity Measure (MEIM), underwent substantial revision in 2007. To inform scholars investigating ethnic identity, we performed a reliability generalization analysis on data from the revised version (MEIM-R) and compared it with data from the original MEIM. Random-effects weighted models evaluated internal consistency coefficients (Cronbach's alpha). Reliability coefficients for the MEIM-R averaged α = .88 across 37 samples, a statistically significant increase over the average of α = .84 for the MEIM across 75 studies. Reliability coefficients for the MEIM-R did not differ across study and participant characteristics such as sample gender and ethnic composition. However, consistently lower reliability coefficients averaging α = .81 were found among participants with low levels of education, suggesting that greater attention to data reliability is warranted when evaluating the ethnic identity of individuals such as middle-school students. Future research will be needed to ascertain whether data with other measures of aspects of personal identity (e.g., racial identity, gender identity) also differ as a function of participant level of education and associated cognitive or maturation processes. (PsycINFO Database Record (c) 2016 APA, all rights reserved).

  8. Characterization of perovskite solar cells: Towards a reliable measurement protocol

    Directory of Open Access Journals (Sweden)

    Eugen Zimmermann

    2016-09-01

    Full Text Available Lead halide perovskite solar cells have shown a tremendous rise in power conversion efficiency with reported record efficiencies of over 20% making this material very promising as a low cost alternative to conventional inorganic solar cells. However, due to a differently severe “hysteretic” behaviour during current density-voltage measurements, which strongly depends on scan rate, device and measurement history, preparation method, device architecture, etc., commonly used solar cell measurements do not give reliable or even reproducible results. For the aspect of commercialization and the possibility to compare results of different devices among different laboratories, it is necessary to establish a measurement protocol which gives reproducible results. Therefore, we compare device characteristics derived from standard current density-voltage measurements with stabilized values obtained from an adaptive tracking of the maximum power point and the open circuit voltage as well as characteristics extracted from time resolved current density-voltage measurements. Our results provide insight into the challenges of a correct determination of device performance and propose a measurement protocol for a reliable characterisation which is easy to implement and has been tested on varying perovskite solar cells fabricated in different laboratories.

  9. Resiliency as a component importance measure in network reliability

    International Nuclear Information System (INIS)

    Whitson, John C.; Ramirez-Marquez, Jose Emmanuel

    2009-01-01

    This paper seeks to define the concept of resiliency as a component importance measure related to network reliability. Resiliency can be defined as a composite of: (1) the ability of a network to provide service despite external failures and (2) the time to restore service when in the presence of such failures. Although, Resiliency has been extensively studied in different research areas, this paper will study the specific aspects of quantifiable network resiliency when the network is experiencing potential catastrophic failures from external events and/or influences, and when it is not known a priori which specific components within the network will fail. A formal definition for Category I resiliency is proposed and a step-by-step approach based on Monte-Carlo simulation to calculate it is defined. To illustrate the approach, two-terminal networks with varying degrees of redundancy, have been considered. The results obtained for test networks show that this new quantifiable concept of resiliency provides insight into the performance and topology of the network. Future use for this work could include methods for safeguarding critical network components and optimizing the use of redundancy as a technique to improve network resiliency.

  10. Improving Metrological Reliability of Information-Measuring Systems Using Mathematical Modeling of Their Metrological Characteristics

    Science.gov (United States)

    Kurnosov, R. Yu; Chernyshova, T. I.; Chernyshov, V. N.

    2018-05-01

    The algorithms for improving the metrological reliability of analogue blocks of measuring channels and information-measuring systems are developed. The proposed algorithms ensure the optimum values of their metrological reliability indices for a given analogue circuit block solution.

  11. A Closed-Form Technique for the Reliability and Risk Assessment of Wind Turbine Systems

    Directory of Open Access Journals (Sweden)

    Leonardo Dueñas-Osorio

    2012-06-01

    Full Text Available This paper proposes a closed-form method to evaluate wind turbine system reliability and associated failure consequences. Monte Carlo simulation, a widely used approach for system reliability assessment, usually requires large numbers of computational experiments, while existing analytical methods are limited to simple system event configurations with a focus on average values of reliability metrics. By analyzing a wind turbine system and its components in a combinatorial yet computationally efficient form, the proposed approach provides an entire probability distribution of system failure that contains all possible configurations of component failure and survival events. The approach is also capable of handling unique component attributes such as downtime and repair cost needed for risk estimations, and enables sensitivity analysis for quantifying the criticality of individual components to wind turbine system reliability. Applications of the technique are illustrated by assessing the reliability of a 12-subassembly turbine system. In addition, component downtimes and repair costs of components are embedded in the formulation to compute expected annual wind turbine unavailability and repair cost probabilities, and component importance metrics useful for maintenance planning and research prioritization. Furthermore, this paper introduces a recursive solution to closed-form method and applies this to a 45-component turbine system. The proposed approach proves to be computationally efficient and yields vital reliability information that could be readily used by wind farm stakeholders for decision making and risk management.

  12. Comparison of reliability and responsiveness of patient-reported clinical outcome measures in knee osteoarthritis rehabilitation.

    Science.gov (United States)

    Williams, Valerie J; Piva, Sara R; Irrgang, James J; Crossley, Chad; Fitzgerald, G Kelley

    2012-08-01

    Secondary analysis, pretreatment-posttreatment observational study. To compare the reliability and responsiveness of the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), the Knee Outcome Survey activities of daily living subscale (KOS-ADL), and the Lower Extremity Functional Scale (LEFS) in individuals with knee osteoarthritis (OA). The WOMAC is the current standard in patient-reported measures of function in patients with knee OA. The KOS-ADL and LEFS were designed for potential use in patients with knee OA. If the KOS-ADL and LEFS are to be considered viable alternatives to the WOMAC for measuring patient-reported function in individuals with knee OA, they should have measurement properties comparable to the WOMAC. It would also be important to determine whether either of these instruments may be superior to the WOMAC in terms of reliability or responsiveness in this population. Data from 168 subjects with knee OA, who participated in a rehabilitation program, were used in the analyses. Reliability and responsiveness of each outcome measure were estimated at follow-ups of 2, 6, and 12 months. Reliability was estimated by calculating the intraclass correlation coefficient (ICC2,1) for subjects who were unchanged in status from baseline at each follow-up time, based on a global rating of change score. To examine responsiveness, the standard error of the measurement, minimal detectable change, minimal clinically important difference, and the Guyatt responsiveness index were calculated for each outcome measure at each follow-up time. All 3 outcome measures demonstrated reasonable reliability and responsiveness to change. Reliability and responsiveness tended to decrease somewhat with increasing follow-up time. There were no substantial differences between outcome measures for reliability or any of the 3 measures of responsiveness at any follow-up time. The results do not indicate that one outcome measure is more reliable or responsive than

  13. A Reliable Measure of Information Security Awareness and the Identification of Bias in Responses

    Directory of Open Access Journals (Sweden)

    Agata McCormac

    2017-11-01

    Full Text Available The Human Aspects of Information Security Questionnaire (HAIS-Q is designed to measure Information Security Awareness. More specifically, the tool measures an individual’s knowledge, attitude, and self-reported behaviour relating to information security in the workplace. This paper reports on the reliability of the HAIS-Q, including test-retest reliability and internal consistency. The paper also assesses the reliability of three preliminary over-claiming items, designed specifically to complement the HAIS-Q, and identify those individuals who provide socially desirable responses. A total of 197 working Australians completed two iterations of the HAIS-Q and the over-claiming items, approximately 4 weeks apart. Results of the analysis showed that the HAIS-Q was externally reliable and internally consistent. Therefore, the HAIS-Q can be used to reliably measure information security awareness. Reliability testing on the preliminary over-claiming items was not as robust and further development is required and recommended. The implications of these findings mean that organisations can confidently use the HAIS-Q to not only measure the current state of employee information security awareness within their organisation, but they can also measure the effectiveness and impacts of training interventions, information security awareness programs and campaigns. The influence of cultural changes and the effect of security incidents can also be assessed.

  14. Testing and evaluation of existing techniques for identifying uptakes and measuring retention of uranium in mill workers

    International Nuclear Information System (INIS)

    1983-03-01

    Preliminary tests and evaluations of existing bio-analytical techniques for identifying uptakes and measuring retention of uranium in mill workers were made at two uranium mills. Urinalysis tests were found to be more reliable indicators of uranium uptakes than personal air sampling. Static air samples were not found to be good indicators of personal uptakes. In vivo measurements of uranium in lung were successfully carried out in the presence of high and fluctuating background radiation. Interference from external contamination was common during end of shift measurements. A full scale study to evaluate model parameters for the uptake, retention and elimination of uranium should include, in addition to the above techniques, particle size determination of airborne uranium, solubility in simulated lung fluid, uranium analysis in faeces and bone and minute volume measurements for each subject

  15. Modeling reliability measurement of interface on information system: Towards the forensic of rules

    Science.gov (United States)

    Nasution, M. K. M.; Sitompul, Darwin; Harahap, Marwan

    2018-02-01

    Today almost all machines depend on the software. As a software and hardware system depends also on the rules that are the procedures for its use. If the procedure or program can be reliably characterized by involving the concept of graph, logic, and probability, then regulatory strength can also be measured accordingly. Therefore, this paper initiates an enumeration model to measure the reliability of interfaces based on the case of information systems supported by the rules of use by the relevant agencies. An enumeration model is obtained based on software reliability calculation.

  16. A review on creatinine measurement techniques.

    Science.gov (United States)

    Mohabbati-Kalejahi, Elham; Azimirad, Vahid; Bahrami, Manouchehr; Ganbari, Ahmad

    2012-08-15

    This paper reviews the entire recent global tendency for creatinine measurement. Creatinine biosensors involve complex relationships between biology and micro-mechatronics to which the blood is subjected. Comparison between new and old methods shows that new techniques (e.g. Molecular Imprinted Polymers based algorithms) are better than old methods (e.g. Elisa) in terms of stability and linear range. All methods and their details for serum, plasma, urine and blood samples are surveyed. They are categorized into five main algorithms: optical, electrochemical, impedometrical, Ion Selective Field-Effect Transistor (ISFET) based technique and chromatography. Response time, detection limit, linear range and selectivity of reported sensors are discussed. Potentiometric measurement technique has the lowest response time of 4-10 s and the lowest detection limit of 0.28 nmol L(-1) belongs to chromatographic technique. Comparison between various techniques of measurements indicates that the best selectivity belongs to MIP based and chromatographic techniques. Copyright © 2012 Elsevier B.V. All rights reserved.

  17. System reliability analysis using dominant failure modes identified by selective searching technique

    International Nuclear Information System (INIS)

    Kim, Dong-Seok; Ok, Seung-Yong; Song, Junho; Koh, Hyun-Moo

    2013-01-01

    The failure of a redundant structural system is often described by innumerable system failure modes such as combinations or sequences of local failures. An efficient approach is proposed to identify dominant failure modes in the space of random variables, and then perform system reliability analysis to compute the system failure probability. To identify dominant failure modes in the decreasing order of their contributions to the system failure probability, a new simulation-based selective searching technique is developed using a genetic algorithm. The system failure probability is computed by a multi-scale matrix-based system reliability (MSR) method. Lower-scale MSR analyses evaluate the probabilities of the identified failure modes and their statistical dependence. A higher-scale MSR analysis evaluates the system failure probability based on the results of the lower-scale analyses. Three illustrative examples demonstrate the efficiency and accuracy of the approach through comparison with existing methods and Monte Carlo simulations. The results show that the proposed method skillfully identifies the dominant failure modes, including those neglected by existing approaches. The multi-scale MSR method accurately evaluates the system failure probability with statistical dependence fully considered. The decoupling between the failure mode identification and the system reliability evaluation allows for effective applications to larger structural systems

  18. Reliability assessment for thickness measurements of pipe wall using probability of detection

    International Nuclear Information System (INIS)

    Nakamoto, Hiroyuki; Kojima, Fumio; Kato, Sho

    2013-01-01

    This paper proposes a reliability assessment method for thickness measurements of pipe wall using probability of detection (POD). Thicknesses of pipes are measured by qualified inspectors with ultrasonic thickness gauges. The inspection results are affected by human factors of the inspectors and include some errors, because the inspectors have different experiences and frequency of inspections. In order to ensure reliability for inspection results, first, POD evaluates experimental results of pipe-wall thickness inspection. We verify that the results have differences depending on inspectors including qualified inspectors. Second, two human factors that affect POD are indicated. Finally, it is confirmed that POD can identify the human factors and ensure reliability for pipe-wall thickness inspections. (author)

  19. Intra and inter-rater reliability study of pelvic floor muscle dynamometric measurements

    Directory of Open Access Journals (Sweden)

    Natalia M. Martinho

    2015-04-01

    Full Text Available OBJECTIVE: The aim of this study was to evaluate the intra and inter-rater reliability of pelvic floor muscle (PFM dynamometric measurements for maximum and average strengths, as well as endurance. METHOD: A convenience sample of 18 nulliparous women, without any urogynecological complaints, aged between 19 and 31 (mean age of 25.4±3.9 participated in this study. They were evaluated using a pelvic floor dynamometer based on load cell technology. The dynamometric evaluations were repeated in three successive sessions: two on the same day with a rest period of 30 minutes between them, and the third on the following day. All participants were evaluated twice in each session; first by examiner 1 followed by examiner 2. The vaginal dynamometry data were analyzed using three parameters: maximum strength, average strength, and endurance. The Intraclass Correlation Coefficient (ICC was applied to estimate the PFM dynamometric measurement reliability, considering a good level as being above 0.75. RESULTS: The intra and inter-raters' analyses showed good reliability for maximum strength (ICCintra-rater1=0.96, ICCintra-rater2=0.95, and ICCinter-rater=0.96, average strength (ICCintra-rater1=0.96, ICCintra-rater2=0.94, and ICCinter-rater=0.97, and endurance (ICCintra-rater1=0.88, ICCintra-rater2=0.86, and ICCinter-rater=0.92 dynamometric measurements. CONCLUSIONS: The PFM dynamometric measurements showed good intra- and inter-rater reliability for maximum strength, average strength and endurance, which demonstrates that this is a reliable device that can be used in clinical practice.

  20. Can Reliability of Multiple Component Measuring Instruments Depend on Response Option Presentation Mode?

    Science.gov (United States)

    Menold, Natalja; Raykov, Tenko

    2016-01-01

    This article examines the possible dependency of composite reliability on presentation format of the elements of a multi-item measuring instrument. Using empirical data and a recent method for interval estimation of group differences in reliability, we demonstrate that the reliability of an instrument need not be the same when polarity of the…

  1. SALP (Sensitivity Analysis by List Processing), a computer assisted technique for binary systems reliability analysis

    International Nuclear Information System (INIS)

    Astolfi, M.; Mancini, G.; Volta, G.; Van Den Muyzenberg, C.L.; Contini, S.; Garribba, S.

    1978-01-01

    A computerized technique which allows the modelling by AND, OR, NOT binary trees, of various complex situations encountered in safety and reliability assessment, is described. By the use of list-processing, numerical and non-numerical types of information are used together. By proper marking of gates and primary events, stand-by systems, common cause failure and multiphase systems can be analyzed. The basic algorithms used in this technique are shown in detail. Application to a stand-by and multiphase system is then illustrated

  2. Reliable Portfolio Selection Problem in Fuzzy Environment: An mλ Measure Based Approach

    Directory of Open Access Journals (Sweden)

    Yuan Feng

    2017-04-01

    Full Text Available This paper investigates a fuzzy portfolio selection problem with guaranteed reliability, in which the fuzzy variables are used to capture the uncertain returns of different securities. To effectively handle the fuzziness in a mathematical way, a new expected value operator and variance of fuzzy variables are defined based on the m λ measure that is a linear combination of the possibility measure and necessity measure to balance the pessimism and optimism in the decision-making process. To formulate the reliable portfolio selection problem, we particularly adopt the expected total return and standard variance of the total return to evaluate the reliability of the investment strategies, producing three risk-guaranteed reliable portfolio selection models. To solve the proposed models, an effective genetic algorithm is designed to generate the approximate optimal solution to the considered problem. Finally, the numerical examples are given to show the performance of the proposed models and algorithm.

  3. Test-retest reliability of behavioral measures of impulsive choice, impulsive action, and inattention.

    Science.gov (United States)

    Weafer, Jessica; Baggott, Matthew J; de Wit, Harriet

    2013-12-01

    Behavioral measures of impulsivity are widely used in substance abuse research, yet relatively little attention has been devoted to establishing their psychometric properties, especially their reliability over repeated administration. The current study examined the test-retest reliability of a battery of standardized behavioral impulsivity tasks, including measures of impulsive choice (i.e., delay discounting, probability discounting, and the Balloon Analogue Risk Task), impulsive action (i.e., the stop signal task, the go/no-go task, and commission errors on the continuous performance task), and inattention (i.e., attention lapses on a simple reaction time task and omission errors on the continuous performance task). Healthy adults (n = 128) performed the battery on two separate occasions. Reliability estimates for the individual tasks ranged from moderate to high, with Pearson correlations within the specific impulsivity domains as follows: impulsive choice (r range: .76-.89, ps reliable measures and thus can be confidently used to assess various facets of impulsivity as intermediate phenotypes for drug abuse.

  4. Proceedings of the OECD/CSNI specialist meeting on advanced instrumentation and measurement techniques

    Energy Technology Data Exchange (ETDEWEB)

    Lehner, J [comp.

    1998-09-01

    In the last few years, tremendous advances in the local instrumentation technology for two-phase flow have been accomplished by the applications of new sensor techniques, optical or beam methods and electronic technology. The detailed measurements gave new insight to the true nature of local mechanisms of interfacial transfer between phases, interfacial structure and two-phase flow turbulent transfers. These new developments indicate that more accurate and reliable two-phase flow models can be obtained, if focused experiments are designed and performed by utilizing this advanced instrumentation. The purpose of this Specialist Meeting on Advanced Instrumentation and Measurement Techniques was to review the recent instrumentation developments and the relation between thermal-hydraulic codes and instrumentation capabilities. Four specific objectives were identified for this meeting: bring together international experts on instrumentation, experiments, and modeling; review recent developments in multiphase flow instrumentation; discuss the relation between modeling needs and instrumentation capabilities, and discuss future directions for instrumentation development, modeling, and experiments.

  5. Proceedings of the OECD/CSNI specialist meeting on advanced instrumentation and measurement techniques

    International Nuclear Information System (INIS)

    Lehner, J.

    1998-09-01

    In the last few years, tremendous advances in the local instrumentation technology for two-phase flow have been accomplished by the applications of new sensor techniques, optical or beam methods and electronic technology. The detailed measurements gave new insight to the true nature of local mechanisms of interfacial transfer between phases, interfacial structure and two-phase flow turbulent transfers. These new developments indicate that more accurate and reliable two-phase flow models can be obtained, if focused experiments are designed and performed by utilizing this advanced instrumentation. The purpose of this Specialist Meeting on Advanced Instrumentation and Measurement Techniques was to review the recent instrumentation developments and the relation between thermal-hydraulic codes and instrumentation capabilities. Four specific objectives were identified for this meeting: bring together international experts on instrumentation, experiments, and modeling; review recent developments in multiphase flow instrumentation; discuss the relation between modeling needs and instrumentation capabilities, and discuss future directions for instrumentation development, modeling, and experiments

  6. Software reliability for safety-critical applications

    International Nuclear Information System (INIS)

    Everett, B.; Musa, J.

    1994-01-01

    In this talk, the authors address the question open-quotes Can Software Reliability Engineering measurement and modeling techniques be applied to safety-critical applications?close quotes Quantitative techniques have long been applied in engineering hardware components of safety-critical applications. The authors have seen a growing acceptance and use of quantitative techniques in engineering software systems but a continuing reluctance in using such techniques in safety-critical applications. The general case posed against using quantitative techniques for software components runs along the following lines: safety-critical applications should be engineered such that catastrophic failures occur less frequently than one in a billion hours of operation; current software measurement/modeling techniques rely on using failure history data collected during testing; one would have to accumulate over a billion operational hours to verify failure rate objectives of about one per billion hours

  7. Relating measurement invariance, cross-level invariance, and multilevel reliability

    NARCIS (Netherlands)

    Jak, S.; Jorgensen, T.D.

    2017-01-01

    Data often have a nested, multilevel structure, for example when data are collected from children in classrooms. This kind of data complicate the evaluation of reliability and measurement invariance, because several properties can be evaluated at both the individual level and the cluster level, as

  8. 4. Measuring technique

    International Nuclear Information System (INIS)

    2006-01-01

    It is noted that in nuclear medicine a most widely the scintillation detectors are applying. Action of these detectors is based on registration of light flares in visible and ultraviolet field arising in scintillator under ionizing radiation action. In the chapter following subchapters are included: gamma-spectrometer and gamma radiation detectors; counter of whole body; measuring of accumulated activity (uptake measurements); scanner; scintillation chamber; single-photon emission computed tomography; positron emission computed tomography; magnet resonance tomography; computer technique, images making

  9. Reliability calculations

    International Nuclear Information System (INIS)

    Petersen, K.E.

    1986-03-01

    Risk and reliability analysis is increasingly being used in evaluations of plant safety and plant reliability. The analysis can be performed either during the design process or during the operation time, with the purpose to improve the safety or the reliability. Due to plant complexity and safety and availability requirements, sophisticated tools, which are flexible and efficient, are needed. Such tools have been developed in the last 20 years and they have to be continuously refined to meet the growing requirements. Two different areas of application were analysed. In structural reliability probabilistic approaches have been introduced in some cases for the calculation of the reliability of structures or components. A new computer program has been developed based upon numerical integration in several variables. In systems reliability Monte Carlo simulation programs are used especially in analysis of very complex systems. In order to increase the applicability of the programs variance reduction techniques can be applied to speed up the calculation process. Variance reduction techniques have been studied and procedures for implementation of importance sampling are suggested. (author)

  10. Test-retest reliability of the multifocal photopic negative response.

    Science.gov (United States)

    Van Alstine, Anthony W; Viswanathan, Suresh

    2017-02-01

    To assess the test-retest reliability of the multifocal photopic negative response (mfPhNR) of normal human subjects. Multifocal electroretinograms were recorded from one eye of 61 healthy adult subjects on two separate days using a Visual Evoked Response Imaging System software version 4.3 (EDI, San Mateo, California). The visual stimulus delivered on a 75-Hz monitor consisted of seven equal-sized hexagons each subtending 12° of visual angle. The m-step exponent was 9, and the m-sequence was slowed to include at least 30 blank frames after each flash. Only the first slice of the first-order kernel was analyzed. The mfPhNR amplitude was measured at a fixed time in the trough from baseline (BT) as well as at the same fixed time in the trough from the preceding b-wave peak (PT). Additionally, we also analyzed BT normalized either to PT (BT/PT) or to the b-wave amplitude (BT/b-wave). The relative reliability of test-retest differences for each test location was estimated by the Wilcoxon matched-pair signed-rank test and intraclass correlation coefficients (ICC). Absolute test-retest reliability was estimated by Bland-Altman analysis. The test-retest amplitude differences for neither of the two measurement techniques were statistically significant as determined by Wilcoxon matched-pair signed-rank test. PT measurements showed greater ICC values than BT amplitude measurements for all test locations. For each measurement technique, the ICC value of the macular response was greater than that of the surrounding locations. The mean test-retest difference was close to zero for both techniques at each of the test locations, and while the coefficient of reliability (COR-1.96 times the standard deviation of the test-retest difference) was comparable for the two techniques at each test location when expressed in nanovolts, the %COR (COR normalized to the mean test and retest amplitudes) was superior for PT than BT measurements. The ICC and COR were comparable for the BT/PT and

  11. Reliability of tunnel angle in ACL reconstruction: two-dimensional versus three-dimensional guide technique.

    Science.gov (United States)

    Leiter, Jeff R S; de Korompay, Nevin; Macdonald, Lindsey; McRae, Sheila; Froese, Warren; Macdonald, Peter B

    2011-08-01

    To compare the reliability of tibial tunnel position and angle produced with a standard ACL guide (two-dimensional guide) or Howell 65° Guide (three-dimensional guide) in the coronal and sagittal planes. In the sagittal plane, the dependent variables were the angle of the tibial tunnel relative to the tibial plateau and the position of the tibial tunnel with respect to the most posterior aspect of the tibia. In the coronal plane, the dependent variables were the angle of the tunnel with respect to the medial joint line of the tibia and the medial and lateral placement of the tibial tunnel relative to the most medial aspect of the tibia. The position and angle of the tibial tunnel in the coronal and sagittal planes were determined from anteroposterior and lateral radiographs, respectively, taken 2-6 months postoperatively. The two-dimensional and three-dimensional guide groups included 28 and 24 sets of radiographs, respectively. Tibial tunnel position was identified, and tunnel angle measurements were completed. Multiple investigators measured the position and angle of the tunnel 3 times, at least 7 days apart. The angle of the tibial tunnel in the coronal plane using a two-dimensional guide (61.3 ± 4.8°) was more horizontal (P guide (64.7 ± 6.2°). The position of the tibial tunnel in the sagittal plane was more anterior (P guide group compared to the three-dimensional guide group (43.3 ± 2.9%). The Howell Tibial Guide allows for reliable placement of the tibial tunnel in the coronal plane at an angle of 65°. Tibial tunnels were within the anatomical footprint of the ACL with either technique. Future studies should investigate the effects of tibial tunnel angle on knee function and patient quality of life. Case-control retrospective comparative study, Level III.

  12. Reliability and Minimum Detectable Change of Temporal-Spatial, Kinematic, and Dynamic Stability Measures during Perturbed Gait.

    Directory of Open Access Journals (Sweden)

    Christopher A Rábago

    Full Text Available Temporal-spatial, kinematic variability, and dynamic stability measures collected during perturbation-based assessment paradigms are often used to identify dysfunction associated with gait instability. However, it remains unclear which measures are most reliable for detecting and tracking responses to perturbations. This study systematically determined the between-session reliability and minimum detectable change values of temporal-spatial, kinematic variability, and dynamic stability measures during three types of perturbed gait. Twenty young healthy adults completed two identical testing sessions two weeks apart, comprised of an unperturbed and three perturbed (cognitive, physical, and visual walking conditions in a virtual reality environment. Within each session, perturbation responses were compared to unperturbed walking using paired t-tests. Between-session reliability and minimum detectable change values were also calculated for each measure and condition. All temporal-spatial, kinematic variability and dynamic stability measures demonstrated fair to excellent between-session reliability. Minimal detectable change values, normalized to mean values ranged from 1-50%. Step width mean and variability measures demonstrated the greatest response to perturbations with excellent between-session reliability and low minimum detectable change values. Orbital stability measures demonstrated specificity to perturbation direction and sensitivity with excellent between-session reliability and low minimum detectable change values. We observed substantially greater between-session reliability and lower minimum detectable change values for local stability measures than previously described which may be the result of averaging across trials within a session and using velocity versus acceleration data for reconstruction of state spaces. Across all perturbation types, temporal-spatial, orbital and local measures were the most reliable measures with the

  13. Measuring walking within and outside the neighborhood in Chinese elders: reliability and validity

    Directory of Open Access Journals (Sweden)

    Cerin Ester

    2011-11-01

    Full Text Available Abstract Background Walking is a preferred, prevalent and recommended activity for aging populations and is influenced by the neighborhood built environment. To study this influence it is necessary to differentiate whether walking occurs within or outside of the neighborhood. The Neighborhood Physical Activity Questionnaire (NPAQ collects information on setting-specific physical activity, including walking, inside and outside one's neighborhood. While the NPAQ has shown to be a reliable measure in adults, its reliability in older adults is unknown. Additionally its validity and the influence of type of neighborhood on reliability and validity have yet to be explored. Methods The NPAQ walking component was adapted for Chinese speaking elders (NWQ-CS. Ninety-six Chinese elders, stratified by social economic status and neighborhood walkability, wore an accelerometer and completed a log of walks for 7 days. Following the collection of valid data the NWQ-CS was interviewer-administered. Fourteen to 20 days (average of 17 days later the NWQ-CS was re-administered. Test-retest reliability and validity of the NWQ-CS were assessed. Results Reliability and validity estimates did not differ with type of neighborhood. NWQ-CS measures of walking showed moderate to excellent reliability. Reliability was generally higher for estimates of weekly frequency than minutes of walking. Total weekly minutes of walking were moderately related to all accelerometry measures. Moderate-to-strong associations were found between the NWQ-CS and log-of-walks variables. The NWQ-CS yielded statistically significantly lower mean values of total walking, weekly minutes of walking for transportation and weekly frequency of walking for transportation outside the neighborhood than the log-of-walks. Conclusions The NWQ-CS showed measurement invariance across types of neighborhoods. It is a valid measure of walking for recreation and frequency of walking for transport. However, it may

  14. Agreement and reliability of femoral varus measurements: a comparison of four techniques

    DEFF Research Database (Denmark)

    Miles, James Edward; Svalastoga, Eiliv Lars; Eriksen, Thomas

    with the diaphysis positioned horizontally and inclined at both 12.5° and 25° to the horizontal. Radiographs were blinded, randomised and read twice by one observer using ImageJ. Using coordinate data, varus angles were calculated using Microsoft Excel for the three previously reported techniques and a novel method...

  15. Calibration techniques for the in vivo measurement of alpha-emitting actinides

    International Nuclear Information System (INIS)

    Fleming, R.R.

    1976-01-01

    Reliable interpretation of in vivo measurements for alpha-emitting actinides deposited in the lungs is largely dependent on three factors: correction of observed count rates for background contributions; correction for photon absorption in the body; and accurate calibration of the counting system. Terrestrial and cosmic radiation contributions can be minimized by extensive shielding and good pulse-shape discrimination. Techniques are available to minimize errors inherent in the calibration of an in vivo counting system. Minimum amounts of alpha-emitting actinides detectable in the lungs are primarily affected by the accuracy of two factors: predicted body background due to 137 Cs and 40 K, and estimated photon absorption in chest-wall tissue. A matched pair of 12.5-cm-dia phoswich detectors, purchased from the Harshaw Chemical Company, are used to measure low-energy photons emitted by the radioactive actinides

  16. A clinical tool to measure plagiocephaly in infants using a flexicurve: a reliability study

    Directory of Open Access Journals (Sweden)

    Leung A

    2013-10-01

    Full Text Available Amy Leung,1 Pauline Watter,2 John Gavranich3 1Department of Physiotherapy, Royal Children's Hospital, Brisbane, Australia; 2Physiotherapy Division, University of Queensland, Brisbane, Australia; 3Child and Family Health Services, West Moreton Health Service District, Ipswich, Australia Purpose: There has been an increasing incidence of infants presenting with plagiocephaly in the last two decades. A practical, economical, and reliable clinical plagiocephaly measure is essential to assess progression and intervention outcomes. This study investigated the reliability of a modified cranial vault asymmetry index using a flexible curve in infants. Measurement: A flexicurve was molded to the infant's head and its shape maintained as it was placed onto paper to trace the head shape. Using a small modification of Loveday and De Chaplain's procedure to measure a cranial vault asymmetry index, a pair of diagonals were drawn at 30° through the midpoint of the central line to their intersection with the traced head outline. The difference in length of the paired diagonals was divided by the short diameter then multiplied by 100%, yielding the modified cranial vault-asymmetry index. Patients and methods: Infants referred to a community health physiotherapist for assessment due to suspected abnormal head shape were included. To explore intrarater reliability, 34 infants aged 3–14 months were measured twice (T1/T1′ at the beginning, and 21 of these remeasured twice at the end (T2/T2′ of their physiotherapy sessions. Test–retest reliability used matched-average data (T1/T1′ and (T2/T2′ from 21 infants. To explore interrater reliability, 18 healthy infants aged 2–6 months were recruited. Each infant was measured once by each rater. Results: For intrarater reliability, the intraclass correlation coefficient with 54 degrees of freedom (ICCdf54 was 0.868 (95% confidence interval [CI] 0.783–0.921; for test–retest reliability, ICCdf20 = 0.958 (95

  17. Reliability of biceps femoris and semitendinosus muscle architecture measurements obtained with ultrasonography

    Directory of Open Access Journals (Sweden)

    Viviane Bastos de Oliveira

    Full Text Available Introduction Currently, little attention is given to the muscle architecture reliability studies of the hamstring using a robust statistical. Our purpose was to determine the reliability of ultrasound measurements of muscle thickness, fascicle length and pennation angle of the biceps femoris and semitendinosus muscles, including heteroskedasticity and internal consistency analyses. Methods Two images of biceps femoris and semitendinosus at 50% of the thigh length were acquired from 21 volunteers, in two visits. The parameters were measured three times in each image, and for each muscle. The reliability was analyzed by the intraclass correlation coefficient (ICC and Cronbach’s alpha (αCronbach. The relative standard error of the measurements (%SEM were calculated and Bland-Altman plots were generated. Results All parameters presented excellent ICC for the three repeated measurements (ICC from 0.93 ‒ 0.99 and moderate to excellent reliability intraday (ICC from 0.70 ‒ 0.95 for both muscles. The present study indicates that ultrasound is a reliable tool to estimate the biceps femoris fascicle length (ICC = 0.97, αCronbach = 0.98, %SEM = 7.86 and semitendinosus (ICC = 0.90, αCronbach = 0.95, %SEM = 7.55, as well as the biceps femoris muscle thickness (ICC = 0.89, αCronbach = 0.94, %SEM = 10.23 and semitendinosus muscle thickness (ICC = 0.87, αCronbach = 0.93, %SEM = 1.35. At last, biceps femoris pennation angle (ICC = 0.93, αCronbach = 0.96 and %SEM = 4.36 and semitendinosus (ICC = 0.96, αCronbach = 0.98 and %SEM = 4.25 also had good repeatability. Conclusion Ultrasonography show good repeatability in estimating of muscle architecture parameters.

  18. Reliability of measuring hip abductor strength following total knee arthroplasty using a hand-held dynamometer.

    Science.gov (United States)

    Schache, Margaret B; McClelland, Jodie A; Webster, Kate E

    2016-01-01

    To investigate the test-retest reliability of measuring hip abductor strength in patients with total knee arthroplasty (TKA) using a hand-held dynamometer (HHD) with two different types of resistance: belt and manual resistance. Test-retest reliability of 30 subjects (17 female, 13 male, 71.9 ± 7.4 years old), 9.2 ± 2.7 days post TKA was measured using belt and therapist resistance. Retest reliability was calculated with intra-class coefficients (ICC3,1) and 95% confidence intervals (CI) for both the group average and the individual scores. A paired t-test assessed whether a difference existed between the belt and therapist methods of resistance. ICCs were 0.82 and 0.80 for the belt and therapist resisted methods, respectively. Hip abductor strength increases of 8 N (14%) for belt resisted and 14 N (17%) for therapist resisted measurements of the group average exceeded the 95% CI and may represent real change. For individuals, hip abductor strength increases of 33 N (72%) (belt resisted) and 57 N (79%) (therapist resisted) could be interpreted as real change. Hip abductor strength can be reliably measured using HHD in the clinical setting with the described protocol. Belt resistance demonstrated slightly higher test-retest reliability. Reliable measurement of hip abductor muscle strength in patients with TKA is important to ensure deficiencies are addressed in rehabilitation programs and function is maximized. Hip abductor strength can be reliably measured with a hand-held dynamometer in the clinical setting using manual or belt resistance.

  19. Reliability of smartphone-based gait measurements for quantification of physical activity/inactivity levels.

    Science.gov (United States)

    Ebara, Takeshi; Azuma, Ryohei; Shoji, Naoto; Matsukawa, Tsuyoshi; Yamada, Yasuyuki; Akiyama, Tomohiro; Kurihara, Takahiro; Yamada, Shota

    2017-11-25

    Objective measurements using built-in smartphone sensors that can measure physical activity/inactivity in daily working life have the potential to provide a new approach to assessing workers' health effects. The aim of this study was to elucidate the characteristics and reliability of built-in step counting sensors on smartphones for development of an easy-to-use objective measurement tool that can be applied in ergonomics or epidemiological research. To evaluate the reliability of step counting sensors embedded in seven major smartphone models, the 6-minute walk test was conducted and the following analyses of sensor precision and accuracy were performed: 1) relationship between actual step count and step count detected by sensors, 2) reliability between smartphones of the same model, and 3) false detection rates when sitting during office work, while riding the subway, and driving. On five of the seven models, the inter-class correlations coefficient (ICC (3,1) ) showed high reliability with a range of 0.956-0.993. The other two models, however, had ranges of 0.443-0.504 and the relative error ratios of the sensor-detected step count to the actual step count were ±48.7%-49.4%. The level of agreement between the same models was ICC (3,1) : 0.992-0.998. The false detection rates differed between the sitting conditions. These results suggest the need for appropriate regulation of step counts measured by sensors, through means such as correction or calibration with a predictive model formula, in order to obtain the highly reliable measurement results that are sought in scientific investigation.

  20. Soft computing approach for reliability optimization: State-of-the-art survey

    International Nuclear Information System (INIS)

    Gen, Mitsuo; Yun, Young Su

    2006-01-01

    In the broadest sense, reliability is a measure of performance of systems. As systems have grown more complex, the consequences of their unreliable behavior have become severe in terms of cost, effort, lives, etc., and the interest in assessing system reliability and the need for improving the reliability of products and systems have become very important. Most solution methods for reliability optimization assume that systems have redundancy components in series and/or parallel systems and alternative designs are available. Reliability optimization problems concentrate on optimal allocation of redundancy components and optimal selection of alternative designs to meet system requirement. In the past two decades, numerous reliability optimization techniques have been proposed. Generally, these techniques can be classified as linear programming, dynamic programming, integer programming, geometric programming, heuristic method, Lagrangean multiplier method and so on. A Genetic Algorithm (GA), as a soft computing approach, is a powerful tool for solving various reliability optimization problems. In this paper, we briefly survey GA-based approach for various reliability optimization problems, such as reliability optimization of redundant system, reliability optimization with alternative design, reliability optimization with time-dependent reliability, reliability optimization with interval coefficients, bicriteria reliability optimization, and reliability optimization with fuzzy goals. We also introduce the hybrid approaches for combining GA with fuzzy logic, neural network and other conventional search techniques. Finally, we have some experiments with an example of various reliability optimization problems using hybrid GA approach

  1. Real-time measurements of suspended sediment concentration and particle size using five techniques

    Science.gov (United States)

    Felix, D.; Albayrak, I.; Abgottspon, A.; Boes, R. M.

    2016-11-01

    Fine sediments are important in the design and operation of hydropower plants (HPPs), in particular with respect to sediment management and hydro-abrasive erosion in hydraulic machines. Therefore, there is a need for reliable real-time measurements of suspended sediment mass concentration (SSC) and particle size distribution (PSD). The following instruments for SSC measurements were investigated in a field study during several years at the HPP Fieschertal in the Swiss Alps: (1) turbidimeters, (2) a Laser In-Situ Scattering and Trans- missometry instrument (LISST), (3) a Coriolis Flow and Density Meter (CFDM), (4) acoustic transducers, and (5) pressure sensors. LISST provided PSDs in addition to concentrations. Reference SSCs were obtained by gravimetrical analysis of automatically taken water samples. In contrast to widely used turbidimeters and the single-frequency acoustic method, SSCs obtained from LISST, the CFDM or the pressure sensors were less or not affected by particle size variations. The CFDM and the pressure sensors allowed measuring higher SSC than the optical or the acoustic techniques (without dilution). The CFDM and the pressure sensors were found to be suitable to measure SSC ≥ 2 g/l. In this paper, the measuring techniques, instruments, setup, methods for data treatment, and selected results are presented and discussed.

  2. A GIS-based assessment of the suitability of SCIAMACHY satellite sensor measurements for estimating reliable CO concentrations in a low-latitude climate.

    Science.gov (United States)

    Fagbeja, Mofoluso A; Hill, Jennifer L; Chatterton, Tim J; Longhurst, James W S

    2015-02-01

    An assessment of the reliability of the Scanning Imaging Absorption Spectrometer for Atmospheric Cartography (SCIAMACHY) satellite sensor measurements to interpolate tropospheric concentrations of carbon monoxide considering the low-latitude climate of the Niger Delta region in Nigeria was conducted. Monthly SCIAMACHY carbon monoxide (CO) column measurements from January 2,003 to December 2005 were interpolated using ordinary kriging technique. The spatio-temporal variations observed in the reliability were based on proximity to the Atlantic Ocean, seasonal variations in the intensities of rainfall and relative humidity, the presence of dust particles from the Sahara desert, industrialization in Southwest Nigeria and biomass burning during the dry season in Northern Nigeria. Spatial reliabilities of 74 and 42 % are observed for the inland and coastal areas, respectively. Temporally, average reliability of 61 and 55 % occur during the dry and wet seasons, respectively. Reliability in the inland and coastal areas was 72 and 38 % during the wet season, and 75 and 46 % during the dry season, respectively. Based on the results, the WFM-DOAS SCIAMACHY CO data product used for this study is therefore relevant in the assessment of CO concentrations in developing countries within the low latitudes that could not afford monitoring infrastructure due to the required high costs. Although the SCIAMACHY sensor is no longer available, it provided cost-effective, reliable and accessible data that could support air quality assessment in developing countries.

  3. Validation and Test-Retest Reliability of New Thermographic Technique Called Thermovision Technique of Dry Needling for Gluteus Minimus Trigger Points in Sciatica Subjects and TrPs-Negative Healthy Volunteers

    Science.gov (United States)

    Rychlik, Michał; Samborski, Włodzimierz

    2015-01-01

    The aim of this study was to assess the validity and test-retest reliability of Thermovision Technique of Dry Needling (TTDN) for the gluteus minimus muscle. TTDN is a new thermography approach used to support trigger points (TrPs) diagnostic criteria by presence of short-term vasomotor reactions occurring in the area where TrPs refer pain. Method. Thirty chronic sciatica patients (n=15 TrP-positive and n=15 TrPs-negative) and 15 healthy volunteers were evaluated by TTDN three times during two consecutive days based on TrPs of the gluteus minimus muscle confirmed additionally by referred pain presence. TTDN employs average temperature (T avr), maximum temperature (T max), low/high isothermal-area, and autonomic referred pain phenomenon (AURP) that reflects vasodilatation/vasoconstriction. Validity and test-retest reliability were assessed concurrently. Results. Two components of TTDN validity and reliability, T avr and AURP, had almost perfect agreement according to κ (e.g., thigh: 0.880 and 0.938; calf: 0.902 and 0.956, resp.). The sensitivity for T avr, T max, AURP, and high isothermal-area was 100% for everyone, but specificity of 100% was for T avr and AURP only. Conclusion. TTDN is a valid and reliable method for T avr and AURP measurement to support TrPs diagnostic criteria for the gluteus minimus muscle when digitally evoked referred pain pattern is present. PMID:26137486

  4. Software reliability

    CERN Document Server

    Bendell, A

    1986-01-01

    Software Reliability reviews some fundamental issues of software reliability as well as the techniques, models, and metrics used to predict the reliability of software. Topics covered include fault avoidance, fault removal, and fault tolerance, along with statistical methods for the objective assessment of predictive accuracy. Development cost models and life-cycle cost models are also discussed. This book is divided into eight sections and begins with a chapter on adaptive modeling used to predict software reliability, followed by a discussion on failure rate in software reliability growth mo

  5. Magnetic particle separation technique: a reliable and simple tool for RIA/IRMA and quantitative PCR assay

    International Nuclear Information System (INIS)

    Shen Rongsen; Shen Decun

    1998-01-01

    Five types of magnetic particles without or with aldehyde, amino and carboxyl functional groups, respectively were used to immobilize first or second antibody by three models, i. e. physical adsorption, chemical coupling and immuno-affinity, forming four types of magnetic particle antibodies. The second antibody immobilized on polyacrolein magnetic particles through aldehyde functional groups and the first antibodies immobilized on carboxylic polystyrene magnetic particles through carboxyl functional groups were recommended to apply to RIAs and/or IRMAs. Streptavidin immobilized on commercial magnetic particles through amino functional groups was successfully applied to separating specific PCR product for quantification of human cytomegalovirus. In the paper typical data on reliability of these magnetic particle ligands were reported and simplicity of the magnetic particle separation technique was discussed. The results showed that the technique was a reliable and simple tool for RIA/IRMA and quantitative PCR assay. (author)

  6. A general software reliability process simulation technique

    Science.gov (United States)

    Tausworthe, Robert C.

    1991-01-01

    The structure and rationale of the generalized software reliability process, together with the design and implementation of a computer program that simulates this process are described. Given assumed parameters of a particular project, the users of this program are able to generate simulated status timelines of work products, numbers of injected anomalies, and the progress of testing, fault isolation, repair, validation, and retest. Such timelines are useful in comparison with actual timeline data, for validating the project input parameters, and for providing data for researchers in reliability prediction modeling.

  7. Reliability of the Q Force; a mobile instrument for measuring isometric quadriceps muscle strength.

    Science.gov (United States)

    Douma, K W; Regterschot, G R H; Krijnen, W P; Slager, G E C; van der Schans, C P; Zijlstra, W

    2016-01-01

    The ability to generate muscle strength is a pre-requisite for all human movement. Decreased quadriceps muscle strength is frequently observed in older adults and is associated with a decreased performance and activity limitations. To quantify the quadriceps muscle strength and to monitor changes over time, instruments and procedures with a sufficient reliability are needed. The Q Force is an innovative mobile muscle strength measurement instrument suitable to measure in various degrees of extension. Measurements between 110 and 130° extension present the highest values and the most significant increase after training. The objective of this study is to determine the test-retest reliability of muscle strength measurements by the Q Force in older adults in 110° extension. Forty-one healthy older adults, 13 males and 28 females were included in the study. Mean (SD) age was 81.9 (4.89) years. Isometric muscle strength of the Quadriceps muscle was assessed with the Q Force at 110° of knee extension. Participants were measured at two sessions with a three to eight day interval between sessions. To determine relative reliability, the intraclass correlation coefficient (ICC) was calculated. To determine absolute reliability, Bland and Altman Limits of Agreement (LOA) were calculated and t-tests were performed. Relative reliability of the Q Force is good to excellent as all ICC coefficients are higher than 0.75. Generally a large 95 % LOA, reflecting only moderate absolute reliability, is found as exemplified for the peak torque left leg of -18.6 N to 33.8 N and the right leg of -9.2 N to 26.4 N was between 15.7 and 23.6 Newton representing 25.2 % to 39.9 % of the size of the mean. Small systematic differences in mean were found between measurement session 1 and 2. The present study shows that the Q Force has excellent relative test-retest reliability, but limited absolute test-retest reliability. Since the Q Force is relatively cheap and mobile it is suitable for

  8. Interrater Reliability of mHealth App Rating Measures: Analysis of Top Depression and Smoking Cessation Apps.

    Science.gov (United States)

    Powell, Adam C; Torous, John; Chan, Steven; Raynor, Geoffrey Stephen; Shwarts, Erik; Shanahan, Meghan; Landman, Adam B

    2016-02-10

    There are over 165,000 mHealth apps currently available to patients, but few have undergone an external quality review. Furthermore, no standardized review method exists, and little has been done to examine the consistency of the evaluation systems themselves. We sought to determine which measures for evaluating the quality of mHealth apps have the greatest interrater reliability. We identified 22 measures for evaluating the quality of apps from the literature. A panel of 6 reviewers reviewed the top 10 depression apps and 10 smoking cessation apps from the Apple iTunes App Store on these measures. Krippendorff's alpha was calculated for each of the measures and reported by app category and in aggregate. The measure for interactiveness and feedback was found to have the greatest overall interrater reliability (alpha=.69). Presence of password protection (alpha=.65), whether the app was uploaded by a health care agency (alpha=.63), the number of consumer ratings (alpha=.59), and several other measures had moderate interrater reliability (alphas>.5). There was the least agreement over whether apps had errors or performance issues (alpha=.15), stated advertising policies (alpha=.16), and were easy to use (alpha=.18). There were substantial differences in the interrater reliabilities of a number of measures when they were applied to depression versus smoking apps. We found wide variation in the interrater reliability of measures used to evaluate apps, and some measures are more robust across categories of apps than others. The measures with the highest degree of interrater reliability tended to be those that involved the least rater discretion. Clinical quality measures such as effectiveness, ease of use, and performance had relatively poor interrater reliability. Subsequent research is needed to determine consistent means for evaluating the performance of apps. Patients and clinicians should consider conducting their own assessments of apps, in conjunction with

  9. Reliability and accuracy analysis of a new semiautomatic radiographic measurement software in adult scoliosis.

    Science.gov (United States)

    Aubin, Carl-Eric; Bellefleur, Christian; Joncas, Julie; de Lanauze, Dominic; Kadoury, Samuel; Blanke, Kathy; Parent, Stefan; Labelle, Hubert

    2011-05-20

    Radiographic software measurement analysis in adult scoliosis. To assess the accuracy as well as the intra- and interobserver reliability of measuring different indices on preoperative adult scoliosis radiographs using a novel measurement software that includes a calibration procedure and semiautomatic features to facilitate the measurement process. Scoliosis requires a careful radiographic evaluation to assess the deformity. Manual and computer radiographic process measures have been studied extensively to determine the reliability and reproducibility in adolescent idiopathic scoliosis. Most studies rely on comparing given measurements, which are repeated by the same user or by an expert user. A given measure with a small intra- or interobserver error might be deemed as good repeatability, but all measurements might not be truly accurate because the ground-truth value is often unknown. Thorough accuracy assessment of radiographic measures is necessary to assess scoliotic deformities, compare these measures at different stages or to permit valid multicenter studies. Thirty-four sets of adult scoliosis digital radiographs were measured two times by three independent observers using a novel radiographic measurement software that includes semiautomatic features to facilitate the measurement process. Twenty different measures taken from the Spinal Deformity Study Group radiographic measurement manual were performed on the coronal and sagittal images. Intra- and intermeasurer reliability for each measure was assessed. The accuracy of the measurement software was also assessed using a physical spine model in six different scoliotic configurations as a true reference. The majority of the measures demonstrated good to excellent intra- and intermeasurer reliability, except for sacral obliquity. The standard variation of all the measures was very small: ≤ 4.2° for Cobb angles, ≤ 4.2° for the kyphosis, ≤ 5.7° for the lordosis, ≤ 3.9° for the pelvic angles, and

  10. FY 1998 annual summary report on photon measuring/processing techniques. Development of highly functional maintenance techniques for power generating facilities; 1998 nendo foton keisoku kako gijutsu. Hatsuden shisetsuyo kokino maintenance gijutsu kaihatsu

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-03-01

    The objectives are set to develop the techniques for non-destructive measurement of conditions of facility portions, especially those exposed to severe environments, e.g., elevated temperature and pressure, over a wide range; the techniques for measurement of leakage of, e.g., gases, at high sensitivity; the techniques of laser-aided welding and surface-modification treatment for the members exposed to severe conditions; and the techniques for generating photon beams of high quality and energy density as the tools therefor, in order to improve reliability and maintenance efficiency of power generating facilities. The R and D themes are microscopic processing technology: fabrication technology for functional micro-composite circuits; in-situ status measuring technology: gas concentration/component measurement technology, and photon wavefront compensation device technology; non-destructive composition measuring technology: high-sensitivity detection technology using short-wavelength photons; high-power all-solid-state laser technology: rod-type laser and slab-type laser; tightly-focusing all-solid-state laser technology: high-energy pulse, high-quality laser; and comprehensive investigation of photonics engineering: investigation for photon-applied measurement technologies. (NEDO)

  11. A Reliable Method to Measure Lip Height Using Photogrammetry in Unilateral Cleft Lip Patients.

    Science.gov (United States)

    van der Zeeuw, Frederique; Murabit, Amera; Volcano, Johnny; Torensma, Bart; Patel, Brijesh; Hay, Norman; Thorburn, Guy; Morris, Paul; Sommerlad, Brian; Gnarra, Maria; van der Horst, Chantal; Kangesu, Loshan

    2015-09-01

    There is still no reliable tool to determine the outcome of the repaired unilateral cleft lip (UCL). The aim of this study was therefore to develop an accurate, reliable tool to measure vertical lip height from photographs. The authors measured the vertical height of the cutaneous and vermilion parts of the lip in 72 anterior-posterior view photographs of 17 patients with repairs to a UCL. Points on the lip's white roll and vermillion were marked on both the cleft and the noncleft sides on each image. Two new concepts were tested. First, photographs were standardized using the horizontal (medial to lateral) eye fissure width (EFW) for calibration. Second, the authors tested the interpupillary line (IPL) and the alar base line (ABL) for their reliability as horizontal lines of reference. Measurements were taken by 2 independent researchers, at 2 different time points each. Overall 2304 data points were obtained and analyzed. Results showed that the method was very effective in measuring the height of the lip on the cleft side with the noncleft side. When using the IPL, inter- and intra-rater reliability was 0.99 to 1.0, with the ABL it varied from 0.91 to 0.99 with one exception at 0.84. The IPL was easier to define because in some subjects the overhanging nasal tip obscured the alar base and gave more consistent measurements possibly because the reconstructed alar base was sometimes indistinct. However, measurements from the IPL can only give the percentage difference between the left and right sides of the lip, whereas those from the ABL can also give exact measurements. Patient examples were given that show how the measurements correlate with clinical assessment. The authors propose this method of photogrammetry with the innovative use of the IPL as a reliable horizontal plane and use of the EFW for calibration as a useful and reliable tool to assess the outcome of UCL repair.

  12. Optimising the measurement of bruises in children across conventional and cross polarized images using segmentation analysis techniques in Image J, Photoshop and circle diameter measurements.

    Science.gov (United States)

    Harris, C; Alcock, A; Trefan, L; Nuttall, D; Evans, S T; Maguire, S; Kemp, A M

    2018-02-01

    Bruising is a common abusive injury in children, and it is standard practice to image and measure them, yet there is no current standard for measuring bruise size consistently. We aim to identify the optimal method of measuring photographic images of bruises, including computerised measurement techniques. 24 children aged Photoshop 'ruler' software (Photoshop diameter)). Inter and intra-observer effects were determined by two individuals repeating 11 electronic measurements, and relevant Intraclass Correlation Coefficient's (ICC's) were used to establish reliability. Spearman's rank correlation was used to compare in vivo with computerised measurements; a comparison of measurement techniques across imaging modalities was conducted using Kolmogorov-Smirnov tests. Significance was set at p 0.5 for all techniques, with maximum Feret diameter and maximum Photoshop diameter on conventional images having the strongest correlation with in vivo measurements. There were significant differences between in vivo and computer-aided measurements, but none between different computer-aided measurement techniques. Overall, computer aided measurements appeared larger than in vivo. Inter- and intra-observer agreement was high for all maximum diameter measurements (ICC's > 0.7). Whilst there are minimal differences between measurements of images obtained, the most consistent results were obtained when conventional images, segmented by Image J Software, were measured with a Feret diameter. This is therefore proposed as a standard for future research, and forensic practice, with the proviso that all computer aided measurements appear larger than in vivo. Copyright © 2018 Elsevier Ltd and Faculty of Forensic and Legal Medicine. All rights reserved.

  13. Reliability and concurrent validity of the iPhone® Compass application to measure thoracic rotation range of motion (ROM) in healthy participants

    Science.gov (United States)

    Schram, Ben; Cox, Alistair J.; Anderson, Sarah L.; Keogh, Justin

    2018-01-01

    Background Several water-based sports (swimming, surfing and stand up paddle boarding) require adequate thoracic mobility (specifically rotation) in order to perform the appropriate activity requirements. The measurement of thoracic spine rotation is problematic for clinicians due to a lack of convenient and reliable measurement techniques. More recently, smartphones have been used to quantify movement in various joints in the body; however, there appears to be a paucity of research using smartphones to assess thoracic spine movement. Therefore, the aim of this study is to determine the reliability (intra and inter rater) and validity of the iPhone® app (Compass) when assessing thoracic spine rotation ROM in healthy individuals. Methods A total of thirty participants were recruited for this study. Thoracic spine rotation ROM was measured using both the current clinical gold standard, a universal goniometer (UG) and the Smart Phone Compass app. Intra-rater and inter-rater reliability was determined with a Intraclass Correlation Coefficient (ICC) and associated 95% confidence intervals (CI). Validation of the Compass app in comparison to the UG was measured using Pearson’s correlation coefficient and levels of agreement were identified with Bland–Altman plots and 95% limits of agreement. Results Both the UG and Compass app measurements both had excellent reproducibility for intra-rater (ICC 0.94–0.98) and inter-rater reliability (ICC 0.72–0.89). However, the Compass app measurements had higher intra-rater reliability (ICC = 0.96 − 0.98; 95% CI [0.93–0.99]; vs. ICC = 0.94 − 0.98; 95% CI [0.88–0.99]) and inter-rater reliability (ICC = 0.87 − 0.89; 95% CI [0.74–0.95] vs. ICC = 0.72 − 0.82; 95% CI [0.21–0.94]). A strong and significant correlation was found between the UG and the Compass app, demonstrating good concurrent validity (r = 0.835, p reliable tool for measuring thoracic spine rotation which produces greater

  14. Techniques for sampling nuclear waste tank contents and in situ measurement of activity

    International Nuclear Information System (INIS)

    Lawrence, R.C.

    1978-04-01

    A study was conducted to develop suitable sampling equipment and techniques for characterizing the mechanical properties of nuclear wastes; identifying effective means of measuring radiation levels, temperatures, and neutron fluxes in situ in wastes; and developing a waste core sampler. A portable, stainless steel probe was developed which is placed in the tank through a riser. This probe is built for the insertion of instrumentation that can measure the contents of the tank at any level and take temperature, radiation, and neutron activation readings with reliable accuracy. A simple and reliable instrument for the in situ extraction of waste materials ranging from liquid to concrete-like substances was also developed. This portable, stainless steel waste core sampler can remove up to one liter of radioactive waste from tanks for transportation to hot cell laboratories for analysis of hardness, chemical form, and isotopic content. A cask for transporting the waste samples from the tanks to the laboratory under radiation-protected conditions was also fabricated. This cask was designed with a ''boot'' or inner-seal liner to contain any radioactive wastes that might remain on the outside of the waste core sampling device

  15. Feasibility and Inter-Rater Reliability of Physical Performance Measures in Acutely Admitted Older Medical Patients

    DEFF Research Database (Denmark)

    Bodilsen, Ann Christine; Juul-Larsen, Helle Gybel; Petersen, Janne

    2015-01-01

    OBJECTIVE: Physical performance measures can be used to predict functional decline and increased dependency in older persons. However, few studies have assessed the feasibility or reliability of such measures in hospitalized older patients. Here we assessed the feasibility and inter-rater reliabi......OBJECTIVE: Physical performance measures can be used to predict functional decline and increased dependency in older persons. However, few studies have assessed the feasibility or reliability of such measures in hospitalized older patients. Here we assessed the feasibility and inter......-rater reliability of four simple measures of physical performance in acutely admitted older medical patients. DESIGN: During the first 24 hours of hospitalization, the following were assessed twice by different raters in 52 (≥ 65 years) patients admitted for acute medical illness: isometric hand grip strength, 4......, and 30-s chair stand were 8%, 7%, and 18%, and the SRD95% values were 22%, 17%, and 49%. CONCLUSION: In acutely admitted older medical patients, grip strength, gait speed, and the Cumulated Ambulation Score measurements were feasible and showed high inter-rater reliability when administered by different...

  16. Toward a Common Language for Measuring Patient Mobility in the Hospital: Reliability and Construct Validity of Interprofessional Mobility Measures.

    Science.gov (United States)

    Hoyer, Erik H; Young, Daniel L; Klein, Lisa M; Kreif, Julie; Shumock, Kara; Hiser, Stephanie; Friedman, Michael; Lavezza, Annette; Jette, Alan; Chan, Kitty S; Needham, Dale M

    2018-02-01

    The lack of common language among interprofessional inpatient clinical teams is an important barrier to achieving inpatient mobilization. In The Johns Hopkins Hospital, the Activity Measure for Post-Acute Care (AM-PAC) Inpatient Mobility Short Form (IMSF), also called "6-Clicks," and the Johns Hopkins Highest Level of Mobility (JH-HLM) are part of routine clinical practice. The measurement characteristics of these tools when used by both nurses and physical therapists for interprofessional communication or assessment are unknown. The purposes of this study were to evaluate the reliability and minimal detectable change of AM-PAC IMSF and JH-HLM when completed by nurses and physical therapists and to evaluate the construct validity of both measures when used by nurses. A prospective evaluation of a convenience sample was used. The test-retest reliability and the interrater reliability of AM-PAC IMSF and JH-HLM for inpatients in the neuroscience department (n = 118) of an academic medical center were evaluated. Each participant was independently scored twice by a team of 2 nurses and 1 physical therapist; a total of 4 physical therapists and 8 nurses participated in reliability testing. In a separate inpatient study protocol (n = 69), construct validity was evaluated via an assessment of convergent validity with other measures of function (grip strength, Katz Activities of Daily Living Scale, 2-minute walk test, 5-times sit-to-stand test) used by 5 nurses. The test-retest reliability values (intraclass correlation coefficients) for physical therapists and nurses were 0.91 and 0.97, respectively, for AM-PAC IMSF and 0.94 and 0.95, respectively, for JH-HLM. The interrater reliability values (intraclass correlation coefficients) between physical therapists and nurses were 0.96 for AM-PAC IMSF and 0.99 for JH-HLM. Construct validity (Spearman correlations) ranged from 0.25 between JH-HLM and right-hand grip strength to 0.80 between AM-PAC IMSF and the Katz Activities of

  17. Analyzing the Reliability of the easyCBM Reading Comprehension Measures: Grade 2. Technical Report #1201

    Science.gov (United States)

    Lai, Cheng-Fei; Irvin, P. Shawn; Alonzo, Julie; Park, Bitnara Jasmine; Tindal, Gerald

    2012-01-01

    In this technical report, we present the results of a reliability study of the second-grade multiple choice reading comprehension measures available on the easyCBM learning system conducted in the spring of 2011. Analyses include split-half reliability, alternate form reliability, person and item reliability as derived from Rasch analysis,…

  18. Analyzing the Reliability of the easyCBM Reading Comprehension Measures: Grade 3. Technical Report #1202

    Science.gov (United States)

    Lai, Cheng-Fei; Irvin, P. Shawn; Park, Bitnara Jasmine; Alonzo, Julie; Tindal, Gerald

    2012-01-01

    In this technical report, we present the results of a reliability study of the third-grade multiple choice reading comprehension measures available on the easyCBM learning system conducted in the spring of 2011. Analyses include split-half reliability, alternate form reliability, person and item reliability as derived from Rasch analysis,…

  19. Analyzing the Reliability of the easyCBM Reading Comprehension Measures: Grade 5. Technical Report #1204

    Science.gov (United States)

    Park, Bitnara Jasmine; Irvin, P. Shawn; Lai, Cheng-Fei; Alonzo, Julie; Tindal, Gerald

    2012-01-01

    In this technical report, we present the results of a reliability study of the fifth-grade multiple choice reading comprehension measures available on the easyCBM learning system conducted in the spring of 2011. Analyses include split-half reliability, alternate form reliability, person and item reliability as derived from Rasch analysis,…

  20. Analyzing the Reliability of the easyCBM Reading Comprehension Measures: Grade 4. Technical Report #1203

    Science.gov (United States)

    Park, Bitnara Jasmine; Irvin, P. Shawn; Alonzo, Julie; Lai, Cheng-Fei; Tindal, Gerald

    2012-01-01

    In this technical report, we present the results of a reliability study of the fourth-grade multiple choice reading comprehension measures available on the easyCBM learning system conducted in the spring of 2011. Analyses include split-half reliability, alternate form reliability, person and item reliability as derived from Rasch analysis,…

  1. Analyzing the Reliability of the easyCBM Reading Comprehension Measures: Grade 6. Technical Report #1205

    Science.gov (United States)

    Irvin, P. Shawn; Alonzo, Julie; Park, Bitnara Jasmine; Lai, Cheng-Fei; Tindal, Gerald

    2012-01-01

    In this technical report, we present the results of a reliability study of the sixth-grade multiple choice reading comprehension measures available on the easyCBM learning system conducted in the spring of 2011. Analyses include split-half reliability, alternate form reliability, person and item reliability as derived from Rasch analysis,…

  2. Analyzing the Reliability of the easyCBM Reading Comprehension Measures: Grade 7. Technical Report #1206

    Science.gov (United States)

    Irvin, P. Shawn; Alonzo, Julie; Lai, Cheng-Fei; Park, Bitnara Jasmine; Tindal, Gerald

    2012-01-01

    In this technical report, we present the results of a reliability study of the seventh-grade multiple choice reading comprehension measures available on the easyCBM learning system conducted in the spring of 2011. Analyses include split-half reliability, alternate form reliability, person and item reliability as derived from Rasch analysis,…

  3. Night-to-night arousal variability and interscorer reliability of arousal measurements.

    Science.gov (United States)

    Loredo, J S; Clausen, J L; Ancoli-Israel, S; Dimsdale, J E

    1999-11-01

    Measurement of arousals from sleep is clinically important, however, their definition is not well standardized, and little data exist on reliability. The purpose of this study is to determine factors that affect arousal scoring reliability and night-to-night arousal variability. The night-to-night arousal variability and interscorer reliability was assessed in 20 subjects with and without obstructive sleep apnea undergoing attended polysomnography during two consecutive nights. Five definitions of arousal were studied, assessing duration of electroencephalographic (EEG) frequency changes, increases in electromyographic (EMG) activity and leg movement, association with respiratory events, as well as the American Sleep Disorders Association (ASDA) definition of arousals. NA. NA. NA. Interscorer reliability varied with the definition of arousal and ranged from an Intraclass correlation (ICC) of 0.19 to 0.92. Arousals that included increases in EMG activity or leg movement had the greatest reliability, especially when associated with respiratory events (ICC 0.76 to 0.92). The ASDA arousal definition had high interscorer reliability (ICC 0.84). Reliability was lowest for arousals consisting of EEG changes lasting <3 seconds (ICC 0.19 to 0.37). The within subjects night-to-night arousal variability was low for all arousal definitions In a heterogeneous population, interscorer arousal reliability is enhanced by increases in EMG activity, leg movements, and respiratory events and decreased by short duration EEG arousals. The arousal index night-to-night variability was low for all definitions.

  4. Low-Budget Instrumentation of a Conventional Leg Press to Measure Reliable Isometric-Strength Capacity.

    Science.gov (United States)

    Baur, Heiner; Groppa, Alessia Severina; Limacher, Regula; Radlinger, Lorenz

    2016-02-02

    Maximum strength and rate of force development (RFD) are 2 important strength characteristics for everyday tasks and athletic performance. Measurements of both parameters must be reliable. Expensive isokinetic devices with isometric modes are often used. The possibility of cost-effective measurements in a practical setting would facilitate quality control. The purpose of this study was to assess the reliability of measurements of maximum isometric strength (Fmax) and RFD on a conventional leg press. Sixteen subjects (23 ± 2 y, 1.68 ± 0.05 m, 59 ± 5 kg) were tested twice within 1 session. After warm-up, subjects performed 2 times 5 trials eliciting maximum voluntary isometric contractions on an instrumented leg press (1- and 2-legged randomized). Fmax (N) and RFD (N/s) were extracted from force-time curves. Reliability was determined for Fmax and RFD by calculating the intraclass correlation coefficient (ICC), the test-retest variability (TRV), and the bias and limits of agreement. Reliability measures revealed good to excellent ICCs of .80-.93. TRV showed mean differences between measurement sessions of 0.4-6.9%. The systematic error was low compared with the absolute mean values (Fmax 5-6%, RFD 1-4%). The implementation of a force transducer into a conventional leg press provides a viable procedure to assess Fmax and RFD. Both performance parameters can be assessed with good to excellent reliability allowing quality control of interventions.

  5. Assessing the accuracy and reliability of ultrasonographic three-dimensional parathyroid volume measurement in a patient with secondary hyperparathyroidism: a comparison with the two-dimensional conventional method

    Energy Technology Data Exchange (ETDEWEB)

    You, Sung Hye; Son, Gyu Ri; Lee, Nam Joon [Dept. of Radiology, Korea University Anam Hospital, Seoul (Korea, Republic of); Suh, Sangil; Ryoo, In Seon; Seol, Hae Young [Dept. of Radiology, Korea University Guro Hospital, Seoul (Korea, Republic of); Lee, Young Hen; Seo, Hyung Suk [Dept. of Radiology, Korea University Ansan Hospital, Ansan (Korea, Republic of)

    2017-01-15

    The purpose of this study was to investigate the accuracy and reliability of the semi-automated ultrasonographic volume measurement tool, virtual organ computer-aided analysis (VOCAL), for measuring the volume of parathyroid glands. Volume measurements for 40 parathyroid glands were performed in patients with secondary hyperparathyroidism caused by chronic renal failure. The volume of the parathyroid glands was measured twice by experienced radiologists by two-dimensional (2D) and three-dimensional (3D) methods using conventional sonograms and the VOCAL with 30°angle increments before parathyroidectomy. The specimen volume was also measured postoperatively. Intraclass correlation coefficients (ICCs) and the absolute percentage error were used for estimating the reproducibility and accuracy of the two different methods. The ICC value between two measurements of the 2D method and the 3D method was 0.956 and 0.999, respectively. The mean absolute percentage error of the 2D method and the 3D VOCAL technique was 29.56% and 5.78%, respectively. For accuracy and reliability, the plots of the 3D method showed a more compact distribution than those of the 2D method on the Bland-Altman graph. The rotational VOCAL method for measuring the parathyroid gland is more accurate and reliable than the conventional 2D measurement. This VOCAL method could be used as a more reliable follow-up imaging modality in a patient with hyperparathyroidism.

  6. Assessing the accuracy and reliability of ultrasonographic three-dimensional parathyroid volume measurement in a patient with secondary hyperparathyroidism: a comparison with the two-dimensional conventional method

    International Nuclear Information System (INIS)

    You, Sung Hye; Son, Gyu Ri; Lee, Nam Joon; Suh, Sangil; Ryoo, In Seon; Seol, Hae Young; Lee, Young Hen; Seo, Hyung Suk

    2017-01-01

    The purpose of this study was to investigate the accuracy and reliability of the semi-automated ultrasonographic volume measurement tool, virtual organ computer-aided analysis (VOCAL), for measuring the volume of parathyroid glands. Volume measurements for 40 parathyroid glands were performed in patients with secondary hyperparathyroidism caused by chronic renal failure. The volume of the parathyroid glands was measured twice by experienced radiologists by two-dimensional (2D) and three-dimensional (3D) methods using conventional sonograms and the VOCAL with 30°angle increments before parathyroidectomy. The specimen volume was also measured postoperatively. Intraclass correlation coefficients (ICCs) and the absolute percentage error were used for estimating the reproducibility and accuracy of the two different methods. The ICC value between two measurements of the 2D method and the 3D method was 0.956 and 0.999, respectively. The mean absolute percentage error of the 2D method and the 3D VOCAL technique was 29.56% and 5.78%, respectively. For accuracy and reliability, the plots of the 3D method showed a more compact distribution than those of the 2D method on the Bland-Altman graph. The rotational VOCAL method for measuring the parathyroid gland is more accurate and reliable than the conventional 2D measurement. This VOCAL method could be used as a more reliable follow-up imaging modality in a patient with hyperparathyroidism

  7. Reliability and measurement error of sagittal spinal motion parameters in 220 patients with chronic low back pain using a three-dimensional measurement device.

    Science.gov (United States)

    Mieritz, Rune M; Bronfort, Gert; Jakobsen, Markus D; Aagaard, Per; Hartvigsen, Jan

    2014-09-01

    A basic premise for any instrument measuring spinal motion is that reliable outcomes can be obtained on a relevant sample under standardized conditions. The purpose of this study was to assess the overall reliability and measurement error of regional spinal sagittal plane motion in patients with chronic low back pain (LBP), and then to evaluate the influence of body mass index, examiner, gender, stability of pain, and pain distribution on reliability and measurement error. This study comprises a test-retest design separated by 7 to 14 days. The patient cohort consisted of 220 individuals with chronic LBP. Kinematics of the lumbar spine were sampled during standardized spinal extension-flexion testing using a 6-df instrumented spatial linkage system. Test-retest reliability and measurement error were evaluated using interclass correlation coefficients (ICC(1,1)) and Bland-Altman limits of agreement (LOAs). The overall test-retest reliability (ICC(1,1)) for various motion parameters ranged from 0.51 to 0.70, and relatively wide LOAs were observed for all parameters. Reliability measures in patient subgroups (ICC(1,1)) ranged between 0.34 and 0.77. In general, greater (ICC(1,1)) coefficients and smaller LOAs were found in subgroups with patients examined by the same examiner, patients with a stable pain level, patients with a body mass index less than below 30 kg/m(2), patients who were men, and patients in the Quebec Task Force classifications Group 1. This study shows that sagittal plane kinematic data from patients with chronic LBP may be sufficiently reliable in measurements of groups of patients. However, because of the large LOAs, this test procedure appears unusable at the individual patient level. Furthermore, reliability and measurement error varies substantially among subgroups of patients. Copyright © 2014 Elsevier Inc. All rights reserved.

  8. Neutron logging reliability techniques and apparatus

    International Nuclear Information System (INIS)

    Johnstone, C.W.

    1978-01-01

    This invention relates in general to neutron logging of earth formations, and in particular, to novel apparatus and procedures for determining the validity, or reliability, of data derived at least in part by logging neutron characteristics of earth formations and, if desired, for affording verifiably accurate indications of such data

  9. Neutron logging reliability techniques and apparatus

    International Nuclear Information System (INIS)

    Johnstone, C.W.

    1974-01-01

    This invention relates in general to neutron logging of earth formations, and in particular, to novel apparatus and procedures for determining the validity, or reliability, of data derived at least in part by logging neutron characteristics of earth formations and, if desired, for affording verifiably accurate indications of such data. (author)

  10. The reliability of repeated TMS measures in older adults and in patients with subacute and chronic stroke

    Directory of Open Access Journals (Sweden)

    Heidi M. Schambra

    2015-09-01

    Full Text Available The reliability of transcranial magnetic stimulation (TMS measures in healthy older adults and stroke patients has been insufficiently characterized. We determined whether common TMS measures could reliably evaluate change in individuals and in groups using the smallest detectable change (SDC, or could tell subjects apart using the intraclass correlation coefficient (ICC. We used a single-rater test-retest design in older healthy, subacute stroke, and chronic stroke subjects. At twice daily sessions on two consecutive days, we recorded resting motor threshold, test stimulus intensity, recruitment curves, short-interval intracortical inhibition and facilitation, and long-interval intracortical inhibition. Using variances estimated from a random effects model, we calculated the SDC and ICC for each TMS measure. For all TMS measures in all groups, SDCs for single subjects were large; only with modest group sizes did the SDCs become low. Thus, while these TMS measures cannot be reliably used as a biomarker to detect individual change, they can reliably detect change exceeding measurement noise in moderate-sized groups. For several of the TMS measures, ICCs were universally high, suggesting that they can reliably discriminate between subjects. Though most TMS measures have sufficient reliability in particular contexts, work establishing their validity, responsiveness, and clinical relevance is still needed.

  11. Dependent systems reliability estimation by structural reliability approach

    DEFF Research Database (Denmark)

    Kostandyan, Erik; Sørensen, John Dalsgaard

    2014-01-01

    Estimation of system reliability by classical system reliability methods generally assumes that the components are statistically independent, thus limiting its applicability in many practical situations. A method is proposed for estimation of the system reliability with dependent components, where...... the leading failure mechanism(s) is described by physics of failure model(s). The proposed method is based on structural reliability techniques and accounts for both statistical and failure effect correlations. It is assumed that failure of any component is due to increasing damage (fatigue phenomena...... identification. Application of the proposed method can be found in many real world systems....

  12. Reliability and Validity of the Behavioral Addiction Measure for Video Gaming.

    Science.gov (United States)

    Sanders, James L; Williams, Robert J

    2016-01-01

    Most tests of video game addiction have weak construct validity and limited ability to correctly identify people in denial. The purpose of the present research was to investigate the reliability and validity of a new test of video game addiction (Behavioral Addiction Measure-Video Gaming [BAM-VG]) that was developed in part to address these deficiencies. Regular adult video gamers (n = 506) were recruited from a Canadian online panel and completed a survey containing three measures of excessive video gaming (BAM-VG; DSM-5 criteria for Internet Gaming Disorder [IGD]; and the IGD-20), as well as questions concerning extensiveness of video game involvement and self-report of problems associated with video gaming. One month later, they were reassessed for the purposes of establishing test-retest reliability. The BAM-VG demonstrated good internal consistency as well as 1 month test-retest reliability. Criterion-related validity was demonstrated by significant correlations with the following: time spent playing, self-identification of video game problems, and scores on other instruments designed to assess video game addiction (DSM-5 IGD, IGD-20). Consistent with the theory, principal component analysis identified two components underlying the BAM-VG that roughly correspond with impaired control and significant negative consequences deriving from this impaired control. Together with its excellent construct validity and other technical features, the BAM-VG represents a reliable and valid test of video game addiction.

  13. The reliability and validity of hand-held refractometry water content measures of hydrogel lenses.

    Science.gov (United States)

    Nichols, Jason J; Mitchell, G Lynn; Good, Gregory W

    2003-06-01

    To investigate within- and between-examiner reliability and validity of hand-held refractometry water content measures of hydrogel lenses. Nineteen lenses of various nominal water contents were examined by two examiners on two occasions separated by 1 hour. An Atago N2 hand-held refractometer was used for all water content measures. Lenses were presented in a random order to each examiner by a third party, and examiners were masked to any potential lens identifiers. Intraclass correlation coefficients (ICC), 95% limits of agreement, and Wilcoxon signed rank test were used to characterize the within- and between-examiner reliability and validity of lens water content measures. Within-examiner reliability was excellent (ICC, 0.97; 95% limits of agreement, -3.6% to +5.7%), and the inter-visit mean difference of 1.1 +/- 2.4% was not biased (p = 0.08). Between-examiner reliability was also excellent (ICC, 0.98; 95% limits of agreement, -4.1% to +3.9%). The mean difference between examiners was -0.1 +/- 2.1% (p = 0.83). The mean difference between the nominally reported water content and our water content measures was -2.1 +/- 1.7% (p refractometry and is material dependent. Therefore, investigators may need to account for bias when measuring hydrogel lens water content via hand-held refractometry.

  14. Non-destructive failure analysis and measurement for molded devices and complex assemblies with X-ray CT and 3D image processing techniques

    International Nuclear Information System (INIS)

    Yin, Xiaoming; Liew, Seaw Jia; Jiang, Ting Ying; Xu, Jian; Kakarala, Ramakrishna

    2013-01-01

    In both automotive and healthcare sectors, reliable failure analysis and accurate measurement of molded devices and complex assemblies are important. Current methods of failure analysis and measurement require these molded parts to be cross-sectioned so that internal features or dimensions can be accessible. As a result, the parts are deemed unusable and additional failure introduced by sectioning may cause misinterpretation of the results. X-ray CT and 3D image processing techniques provide a new nondestructive solution for failure analysis and measurement of molded devices and complex assemblies. These techniques simplify failure analysis and measurement of molded devices and assemblies, and improve the productivity of molding manufacturing significantly.

  15. Measuring awareness of financial skills: reliability and validity of a new measure.

    Science.gov (United States)

    Cramer, K; Tuokko, H A; Mateer, C A; Hultsch, D F

    2004-03-01

    This paper examines the psychometric properties of a three-part (participant, informant, and performance) Measure for assessing Awareness of Financial Skills (MAFS). The MAFS was administered to 10 seniors with dementia and 25 well-functioning seniors, and their informants. Measures of cognitive functioning, social desirability, neuroticism, and perceived control were administered to each participant to allow for an assessment of validity. Internal consistency estimates for the participant and informant questionnaires were found to be 0.92 and 0.97, respectively. Convergent validity analysis indicated that performance on this measure was related to level of cognitive functioning, with higher level of unawareness associated with decreased cognitive ability. Discriminant validity analysis showed that performance on this measure was not related to social desirability or neuroticism. This study provides evidence that the MAFS is a reliable and valid tool for assessing awareness of financial skills in older adults.

  16. New diffusive gradients in a thin film technique for measuring inorganic arsenic and selenium(IV) using a titanium dioxide based adsorbent

    DEFF Research Database (Denmark)

    Bennett, William W.; Teasdale, Peter R.; Panther, Jared G.

    2010-01-01

    A new diffusive gradients in a thin film (DGT) technique, using a titanium dioxide based adsorbent (Metsorb), has been developed and evaluated for the determination of dissolved inorganic arsenic and selenium. AsIII, AsV, and SeIV were found to be quantitatively accumulated by the adsorbent (uptake...... measurement of inorganic arsenic. Reproducibility of the technique in field deployments was good (relative standard deviation arsenic and 0.05 μg L-1 for SeIV. The results of this study confirmed that DGT with Metsorb was a reliable...... and robust method for the measurement of inorganic arsenic and the selective measurement of SeIV within useful limits of accuracy....

  17. Reliability and Accuracy of Brain Volume Measurement on MR Imaging

    DEFF Research Database (Denmark)

    Yamagchii, Kechiro; Lassen, Anders; Ring, Poul

    1998-01-01

    Yamaguchi, K., Lassen, A. And Ring, P. Reliability and Accuracy of Brain Volume Measurement on MR Imaging. Abstract at ESMRMB98 European Society for Magnetic Resonance in Medicine and Biology, Geneva, Sept 17-20, 1998 Danish Research Center for Magnetic Resonance, Hvidovre University Hospital...

  18. Reliability of the craniocervical posture assessment: visual and angular measurements using photographs and radiographs.

    Science.gov (United States)

    Gadotti, Inae C; Armijo-Olivo, Susan; Silveira, Anelise; Magee, David

    2013-01-01

    The purposes of this study were to determine the intrarater and interrater reliability of the craniocervical posture in a sagittal view using quantitative measurements on photographs and radiographs and to determine the agreement of the visual assessment of posture between raters. One photograph and 1 radiograph of the sagittal craniocervical posture were simultaneously taken from 39 healthy female subjects. Three angles were measured on the photographs and 10 angles on the radiographs of 22 subjects using Alcimage software (Alcimage; Uberlândia, MG, Brazil). Two repeated measurements were performed by 2 raters. The measurements were compared within and between raters to test the intrarater and interrater reliability, respectively. Intraclass correlation coefficient and SEM were used. κ Agreement was calculated for the visual assessment of 39 subjects using photographs and radiographs between 2 raters. Good to excellent intrarater and interrater intraclass correlation coefficient values were found on both photographs and radiographs. Interrater SEM was large and clinically significant for cervical lordosis photogrammetry and for 1 angle measuring cervical lordosis on radiographs. Interrater κ agreement for the visual assessment using photographs was poor (κ = 0.37). The raters were reliable to measure angles in photographs and radiographs to quantify craniocervical posture with exception of 2 angles measuring lordosis of the cervical spine when compared between raters. The visual assessment of posture between raters was not reliable. © 2013. Published by National University of Health Sciences All rights reserved.

  19. Isotope measurement techniques for atmospheric methane

    International Nuclear Information System (INIS)

    Lowe, D.; White, J.; Levin, I.; Wahlen, M.; Miller, J.B.; Bergamaschi, P.

    2002-01-01

    Measurement techniques for the carbon isotopic composition of atmospheric methane (δ 13 C) are described in detail as applied in several leading institutions active in this field since many years. The standard techniques with offline sample preparation and subsequent measurement by dual inlet isotope ratio mass spectrometry (IRMS) are compared with continuous flow IRMS. The potential use of infrared absorption spectroscopy is briefly discussed. Details on quality control and calibration are provided. Basic analytical aspects for the measurement of other species, 2 H and 14 C, are also given. (author)

  20. Reliability and concurrent validity of the iPhone® Compass application to measure thoracic rotation range of motion (ROM in healthy participants

    Directory of Open Access Journals (Sweden)

    James Furness

    2018-03-01

    Full Text Available Background Several water-based sports (swimming, surfing and stand up paddle boarding require adequate thoracic mobility (specifically rotation in order to perform the appropriate activity requirements. The measurement of thoracic spine rotation is problematic for clinicians due to a lack of convenient and reliable measurement techniques. More recently, smartphones have been used to quantify movement in various joints in the body; however, there appears to be a paucity of research using smartphones to assess thoracic spine movement. Therefore, the aim of this study is to determine the reliability (intra and inter rater and validity of the iPhone® app (Compass when assessing thoracic spine rotation ROM in healthy individuals. Methods A total of thirty participants were recruited for this study. Thoracic spine rotation ROM was measured using both the current clinical gold standard, a universal goniometer (UG and the Smart Phone Compass app. Intra-rater and inter-rater reliability was determined with a Intraclass Correlation Coefficient (ICC and associated 95% confidence intervals (CI. Validation of the Compass app in comparison to the UG was measured using Pearson’s correlation coefficient and levels of agreement were identified with Bland–Altman plots and 95% limits of agreement. Results Both the UG and Compass app measurements both had excellent reproducibility for intra-rater (ICC 0.94–0.98 and inter-rater reliability (ICC 0.72–0.89. However, the Compass app measurements had higher intra-rater reliability (ICC = 0.96 − 0.98; 95% CI [0.93–0.99]; vs. ICC = 0.94 − 0.98; 95% CI [0.88–0.99] and inter-rater reliability (ICC = 0.87 − 0.89; 95% CI [0.74–0.95] vs. ICC = 0.72 − 0.82; 95% CI [0.21–0.94]. A strong and significant correlation was found between the UG and the Compass app, demonstrating good concurrent validity (r = 0.835, p < 0.001. Levels of agreement between the two devices were 24.8° (LoA –9

  1. Reliability Measure Model for Assistive Care Loop Framework Using Wireless Sensor Networks

    Directory of Open Access Journals (Sweden)

    Venki Balasubramanian

    2010-01-01

    Full Text Available Body area wireless sensor networks (BAWSNs are time-critical systems that rely on the collective data of a group of sensor nodes. Reliable data received at the sink is based on the collective data provided by all the source sensor nodes and not on individual data. Unlike conventional reliability, the definition of retransmission is inapplicable in a BAWSN and would only lead to an elapsed data arrival that is not acceptable for time-critical application. Time-driven applications require high data reliability to maintain detection and responses. Hence, the transmission reliability for the BAWSN should be based on the critical time. In this paper, we develop a theoretical model to measure a BAWSN's transmission reliability, based on the critical time. The proposed model is evaluated through simulation and then compared with the experimental results conducted in our existing Active Care Loop Framework (ACLF. We further show the effect of the sink buffer in transmission reliability after a detailed study of various other co-existing parameters.

  2. Reliability of isometric lower-extremity muscle strength measurements in children with cerebral palsy: implications for measurement design

    NARCIS (Netherlands)

    Willemse, Lydia; Brehm, Merel A.; Scholtes, Vanessa A.; Jansen, Laura; Woudenberg-Vos, Hester; Dallmeijer, Annet J.

    2013-01-01

    Children with cerebral palsy (CP) typically show muscle weakness of the lower extremities, which can be measured with the use of handheld dynamometry (HHD). The purposes of this study were: (1) to determine test-retest reliability and measurement error of isometric lower-extremity strength

  3. Reliability of computed tomography measurements in assessment of thigh muscle cross-sectional area and attenuation

    International Nuclear Information System (INIS)

    Strandberg, Sören; Wretling, Marie-Louise; Wredmark, Torsten; Shalabi, Adel

    2010-01-01

    Advancement in technology of computer tomography (CT) and introduction of new medical imaging softwares enables easy and rapid assessment of muscle cross-sectional area (CSA) and attenuation. Before using these techniques in clinical studies there is a need for evaluation of the reliability of the measurements. The purpose of the study was to evaluate the inter- and intra-observer reliability of ImageJ in measuring thigh muscles CSA and attenuation in patients with anterior cruciate ligament (ACL) injury by computer tomography. 31 patients from an ongoing study of rehabilitation and muscle atrophy after ACL reconstruction were included in the study. Axial CT images with slice thickness of 10 mm at the level of 150 mm above the knee joint were analyzed by two investigators independently at two times with a minimum of 3 weeks between the two readings using NIH ImageJ. CSA and the mean attenuation of individual thigh muscles were analyzed for both legs. Mean CSA and mean attenuation values were in good agreement both when comparing the two observers and the two replicates. The inter- and intraclass correlation (ICC) was generally very high with values from 0.98 to 1.00 for all comparisons except for the area of semimembranosus. All the ICC values were significant (p < 0,001). Pearson correlation coefficients were also generally very high with values from 0.98 to 1.00 for all comparisons except for the area of semimembranosus (0.95 for intraobserver and 0.92 for interobserver). This study has presented ImageJ as a method to monitor and evaluate CSA and attenuation of different muscles in the thigh using CT-imaging. The method shows an overall excellent reliability with respect to both observer and replicate

  4. Reliability of Instruments Measuring At-Risk and Problem Gambling Among Young Individuals

    DEFF Research Database (Denmark)

    Edgren, Robert; Castrén, Sari; Mäkelä, Marjukka

    2016-01-01

    This review aims to clarify which instruments measuring at-risk and problem gambling (ARPG) among youth are reliable and valid in light of reported estimates of internal consistency, classification accuracy, and psychometric properties. A systematic search was conducted in PubMed, Medline, and Psyc......Info covering the years 2009–2015. In total, 50 original research articles fulfilled the inclusion criteria: target age under 29 years, using an instrument designed for youth, and reporting a reliability estimate. Articles were evaluated with the revised Quality Assessment of Diagnostic Accuracy Studies tool....... Reliability estimates were reported for five ARPG instruments. Most studies (66%) evaluated the South Oaks Gambling Screen Revised for Adolescents. The Gambling Addictive Behavior Scale for Adolescents was the only novel instrument. In general, the evaluation of instrument reliability was superficial. Despite...

  5. Application of image based measurement techniques for the investigation of aeroengine performance on a commercial aircraft in ground operation

    OpenAIRE

    Schröder, Andreas; Geisler, Reinhard; Schanz, Daniel; Agocs, Janos; Pallek, Dieter; Schroll, Michael; Klinner, Joachim; Beversdorff, Manfred; Voges, Melanie; Willert, Christian

    2014-01-01

    The investigation of the flow and sound field upstream and downstream of a full scale aeroengine is aimed at providing important reference data required for reliable modeling and prediction. In this regard a wide variety of contactless and non-invasive laser optical and acoustic measurement techniques have matured in recent years to allow their application on full scale aircraft. Within a measurement campaign involving an Airbus A320 DLR research aircraft inside a sound-attenuating hangar at ...

  6. Reliability of electronic systems

    International Nuclear Information System (INIS)

    Roca, Jose L.

    2001-01-01

    Reliability techniques have been developed subsequently as a need of the diverse engineering disciplines, nevertheless they are not few those that think they have been work a lot on reliability before the same word was used in the current context. Military, space and nuclear industries were the first ones that have been involved in this topic, however not only in these environments it is that it has been carried out this small great revolution in benefit of the increase of the reliability figures of the products of those industries, but rather it has extended to the whole industry. The fact of the massive production, characteristic of the current industries, drove four decades ago, to the fall of the reliability of its products, on one hand, because the massively itself and, for other, to the recently discovered and even not stabilized industrial techniques. Industry should be changed according to those two new requirements, creating products of medium complexity and assuring an enough reliability appropriated to production costs and controls. Reliability began to be integral part of the manufactured product. Facing this philosophy, the book describes reliability techniques applied to electronics systems and provides a coherent and rigorous framework for these diverse activities providing a unifying scientific basis for the entire subject. It consists of eight chapters plus a lot of statistical tables and an extensive annotated bibliography. Chapters embrace the following topics: 1- Introduction to Reliability; 2- Basic Mathematical Concepts; 3- Catastrophic Failure Models; 4-Parametric Failure Models; 5- Systems Reliability; 6- Reliability in Design and Project; 7- Reliability Tests; 8- Software Reliability. This book is in Spanish language and has a potentially diverse audience as a text book from academic to industrial courses. (author)

  7. Assessing the accuracy and reliability of ultrasonographic three-dimensional parathyroid volume measurement in a patient with secondary hyperparathyroidism: a comparison with the two-dimensional conventional method

    Directory of Open Access Journals (Sweden)

    Sung-Hye You

    2017-01-01

    Full Text Available Purpose The purpose of this study was to investigate the accuracy and reliability of the semi-automated ultrasonographic volume measurement tool, virtual organ computer-aided analysis (VOCAL, for measuring the volume of parathyroid glands. Methods Volume measurements for 40 parathyroid glands were performed in patients with secondary hyperparathyroidism caused by chronic renal failure. The volume of the parathyroid glands was measured twice by experienced radiologists by two-dimensional (2D and three-dimensional (3D methods using conventional sonograms and the VOCAL with 30°angle increments before parathyroidectomy. The specimen volume was also measured postoperatively. Intraclass correlation coefficients (ICCs and the absolute percentage error were used for estimating the reproducibility and accuracy of the two different methods. Results The ICC value between two measurements of the 2D method and the 3D method was 0.956 and 0.999, respectively. The mean absolute percentage error of the 2D method and the 3D VOCAL technique was 29.56% and 5.78%, respectively. For accuracy and reliability, the plots of the 3D method showed a more compact distribution than those of the 2D method on the Bland-Altman graph. Conclusion The rotational VOCAL method for measuring the parathyroid gland is more accurate and reliable than the conventional 2D measurement. This VOCAL method could be used as a more reliable follow-up imaging modality in a patient with hyperparathyroidism.

  8. A critique of reliability prediction techniques for avionics applications

    Directory of Open Access Journals (Sweden)

    Guru Prasad PANDIAN

    2018-01-01

    Full Text Available Avionics (aeronautics and aerospace industries must rely on components and systems of demonstrated high reliability. For this, handbook-based methods have been traditionally used to design for reliability, develop test plans, and define maintenance requirements and sustainment logistics. However, these methods have been criticized as flawed and leading to inaccurate and misleading results. In its recent report on enhancing defense system reliability, the U.S. National Academy of Sciences has recently discredited these methods, judging the Military Handbook (MIL-HDBK-217 and its progeny as invalid and inaccurate. This paper discusses the issues that arise with the use of handbook-based methods in commercial and military avionics applications. Alternative approaches to reliability design (and its demonstration are also discussed, including similarity analysis, testing, physics-of-failure, and data analytics for prognostics and systems health management.

  9. Reliability of Using Motion Sensors to Measure Children’s Physical Activity Levels in Exergaming

    Directory of Open Access Journals (Sweden)

    Nan Zeng

    2018-05-01

    Full Text Available Objectives: This study examined the reliability of two objective measurement tools in assessing children’s physical activity (PA levels in an exergaming setting. Methods: A total of 377 children (190 girls, Mage = 8.39, SD = 1.55 attended the 30-min exergaming class every other day for 18 weeks. Children’s PA levels were concurrently measured by NL-1000 pedometer and ActiGraph GT3X accelerometer, while children’s steps per min and time engaged in sedentary, light, and moderate-to-vigorous PA were estimated, respectively. Results: The results of intraclass correlation coefficient (ICC indicated a low degree of reliability (single measures ICC = 0.03 in accelerometers. ANOVA did detect a possible learning effect for 27 classes (p < 0.01, and the single measures ICC was 0.20 for pedometers. Moreover, there was no significant positive relationship between steps per min and time spent in moderate-to-vigorous physical activity (MVPA. Finally, only 1.3% variance was explained by pedometer as a predictor using Hierarchical Linear Modeling to further explore the relationship between pedometer and accelerometer data. Conclusions: The NL-1000 pedometers and ActiGraph GT3X accelerometers have low reliability in assessing elementary school children’s PA levels during exergaming. More research is warranted in determining the reliable and accurate measurement information regarding the use of modern devices in exergaming setting.

  10. Conceptual Software Reliability Prediction Models for Nuclear Power Plant Safety Systems

    International Nuclear Information System (INIS)

    Johnson, G.; Lawrence, D.; Yu, H.

    2000-01-01

    The objective of this project is to develop a method to predict the potential reliability of software to be used in a digital system instrumentation and control system. The reliability prediction is to make use of existing measures of software reliability such as those described in IEEE Std 982 and 982.2. This prediction must be of sufficient accuracy to provide a value for uncertainty that could be used in a nuclear power plant probabilistic risk assessment (PRA). For the purposes of the project, reliability was defined to be the probability that the digital system will successfully perform its intended safety function (for the distribution of conditions under which it is expected to respond) upon demand with no unintended functions that might affect system safety. The ultimate objective is to use the identified measures to develop a method for predicting the potential quantitative reliability of a digital system. The reliability prediction models proposed in this report are conceptual in nature. That is, possible prediction techniques are proposed and trial models are built, but in order to become a useful tool for predicting reliability, the models must be tested, modified according to the results, and validated. Using methods outlined by this project, models could be constructed to develop reliability estimates for elements of software systems. This would require careful review and refinement of the models, development of model parameters from actual experience data or expert elicitation, and careful validation. By combining these reliability estimates (generated from the validated models for the constituent parts) in structural software models, the reliability of the software system could then be predicted. Modeling digital system reliability will also require that methods be developed for combining reliability estimates for hardware and software. System structural models must also be developed in order to predict system reliability based upon the reliability

  11. Hole Drilling Technique – on site stress measurement

    OpenAIRE

    Schueremans, Luc

    2009-01-01

    2. Hole Drilling Technique for onsite stress measurement has been used to validate the stress level at 2 pillars of the Sint-Jacobschurch (Leuven, B). The technique allows estimating the stress in a stone from measuring deformation when a small hole is made. It is a low intrusive technique. The application of it is limited to local stress measurements and is a complement to stress estimate from calculations of from the use of –for example- flat jacks. In addition to the flat-jack technique...

  12. Measurement of interfacial tension by use of pendant drop video techniques

    Science.gov (United States)

    Herd, Melvin D.; Thomas, Charles P.; Bala, Gregory A.; Lassahn, Gordon D.

    1993-09-01

    This report describes an instrument to measure the interfacial tension (IFT) of aqueous surfactant solutions and crude oil. The method involves injection of a drop of fluid (such as crude oil) into a second immiscible phase to determine the IFT between the two phases. The instrument is composed of an AT-class computer, optical cell, illumination, video camera and lens, video frame digitizer board, monitor, and software. The camera displays an image of the pendant drop on the monitor, which is then processed by the frame digitizer board and non-proprietary software to determine the IFT. Several binary and ternary phase systems were taken from the literature and used to measure the precision and accuracy of the instrument in determining IFT's. A copy of the software program is included in the report. A copy of the program on diskette can be obtained from the Energy Science and Technology Software Center, P.O. Box 1020, Oak Ridge, TN 37831-1020. The accuracy and precision of the technique and apparatus presented is very good for measurement of IFT's in the range from 72 to 10(exp -2) mN/m, which is adequate for many EOR applications. With modifications to the equipment and the numerical techniques, measurements of ultralow IFT's (less than 10(exp -3) mN/m) should be possible as well as measurements at reservoir temperature and pressure conditions. The instrument has been used at the Idaho National Engineering Laboratory to support the research program on microbial enhanced oil recovery. Measurements of IFT's for several bacterial supernatants and unfractionated acid precipitates of microbial cultures containing biosurfactants against medium to heavy crude oils are reported. These experiments demonstrate that the use of automated video imaging of pendant drops is a simple and fast method to reliably determine interfacial tension between two immiscible liquid phases, or between a gas and a liquid phase.

  13. How to measure distinct components of visual attention fast and reliably

    DEFF Research Database (Denmark)

    Vangkilde, Signe Allerup; Kyllingsbæk, Søren; Habekost, Thomas

    2009-01-01

    Measuring different attentional processes in a fast and reliable way is important in both clinical and experimental settings. However, most tests of visual attention are either lengthy or lack sensitivity, specificity, and reliability. To address this we developed a ten minute test procedure...... for the Swedish Betula-project, a longitudinal study investigating changes in cognitive functions over the adult life span (Nilsson et al., 2004). The test consists of a computer-based letter recognition task with stimulus displays of varied durations followed by pattern masks or a blank screen. The temporal...

  14. Reliability and responsiveness of algometry for measuring pressure pain threshold in patients with knee osteoarthritis.

    Science.gov (United States)

    Mutlu, Ebru Kaya; Ozdincler, Arzu Razak

    2015-06-01

    [Purpose] This study aimed to establish the intrarater reliability and responsiveness of a clinically available algometer in patients with knee osteoarthritis as well as to determine the minimum-detectable-change and standard error of measurement of testing to facilitate clinical interpretation of temporal changes. [Subjects] Seventy-three patients with knee osteoarthritis were included. [Methods] Pressure pain threshold measured by algometry was evaluated 3 times at 2-min intervals over 2 clinically relevant sites-mediolateral to the medial femoral tubercle (distal) and lateral to the medial malleolus (local)-on the same day. Intrarater reliability was estimated by intraclass correlation coefficients. The minimum-detectable-change and standard error of measurement were calculated. As a measure of responsiveness, the effect size was calculated for the results at baseline and after treatment. [Results] The intrarater reliability was almost perfect (intraclass correlation coefficient = 0.93-0.97). The standard error of measurement and minimum-detectable-change were 0.70-0.66 and 1.62-1.53, respectively. The pressure pain threshold over the distal site was inadequately responsive in knee osteoarthritis, but the local site was responsive. The effect size was 0.70. [Conclusion] Algometry is reliable and responsive to assess measures of pressure pain threshold for evaluating pain patients with knee osteoarthritis.

  15. Factors associated with the impossibility to obtain reliable liver stiffness measurements by means of Acoustic Radiation Force Impulse (ARFI) elastography—Analysis of a cohort of 1031 subjects

    Energy Technology Data Exchange (ETDEWEB)

    Bota, Simona, E-mail: bota_simona1982@yahoo.com; Sporea, Ioan, E-mail: isporea@umft.ro; Sirli, Roxana, E-mail: roxanasirli@gmail.com; Popescu, Alina, E-mail: alinamircea.popescu@gmail.com; Danila, Mirela, E-mail: mireladanila@gmail.com; Jurchis, Ana, E-mail: ana.jurchis@yahoo.com; Gradinaru-Tascau, Oana, E-mail: bluonmyown@yahoo.com

    2014-02-15

    Introduction: Acoustic Radiation Force Impulse (ARFI) elastography is a non-invasive technique for liver fibrosis assessment. Aim: To assess the feasibility of ARFI elastography in a large cohort of subjects and to identify factors associated with impossibility to obtain reliable liver stiffness (LS) measurements by means of this technique. Methods: Our retrospective study included 1031 adult subjects with or without chronic liver disease. In each subject LS was assessed by means of ARFI elastography. Failure of ARFI measurements was defined if no valid measurement was obtained after at least 10 shots and unreliable in the following situations: fewer than 10 valid shots; or median value of 10 valid measurements with a success rate (SR) < 60% and/or an interquartile range interval (IQR) ≥ 30%. Results: Failure of LS measurements by means of ARFI was observed in 4 subjects (0.3%), unreliable measurements in 66 subjects (6.4%), so reliable measurements were obtained in 961 subjects (93.3%). In univariant analysis, the following risk factors were associated with failed and unreliable measurements: age over 58 years (OR = 0.49; 95% CI 0.30–0.80, p = 0.005), male gender (OR = 0.58; 95% CI 0.34–0.94, p = 0.04), BMI > 27.7 kg/m{sup 2} (OR = 0.23, 95% CI 0.13–0.41, p < 0.0001). In multivariate analysis all the factors mentioned above were independently associated with the risk of failed and unreliable measurements. Conclusions: Reliable LS measurements by means of ARFI elastography were obtained in 93.3% of cases. Older age, higher BMI and male gender were associated with the risk of failed and unreliable measurements, but their influence is limited as compared with Transient Elastography.

  16. Magnetic resonance imaging of shoulders with idiopathic adhesive capsulitis: reliability of measures

    Energy Technology Data Exchange (ETDEWEB)

    Lefevre-Colau, Marie-Martine; Fayad, Fouad; Rannou, Francois; Demaille-Wlodyka, Samantha; Mayoux-Benhamou, Marie-Anne; Poiraudeau, Serge; Revel, Michel [Universite Rene Descartes, Department of Physical and Rehabilitation Medicine, Hopital Cochin (AP-HP), Paris (France); Drape, Jean-Luc; Diche, Thierry; Minvielle, Francois [Hopital Cochin (AP-HP), Department of Radiology B, Paris (France); Fermanian, Jacques [Universite Rene Descartes, Department of Biostatistics, Hopital Necker (AP-HP), Paris (France)

    2005-12-01

    The magnetic resonance imaging (MRI) findings in idiopathic adhesive capsulitis (AC) were compared with those of contralateral healthy shoulders and the reliability of measures assessed. Twenty-six consecutive patients (26 AC and 14 healthy shoulders) were prospectively assessed. The main measurements were thickness of the joint capsule and synovial membrane in the axillary recess and rotator interval in T1-weighted spin-echo sequence enhanced with intravenous (IV) gadolinium chelate (Gd-chelate). Reliability was studied by use of the intraclass correlation coefficient (ICC). The mean thickness of the axillary recess on the coronal plane was 9.0{+-}2.2 mm in AC shoulders and 0.4{+-}0.7 mm in healthy shoulders. The mean thickness of the rotator interval on the sagittal plane was 8.4{+-}2.8 in AC shoulders and 0.6{+-}0.8 mm in healthy shoulders. Interobserver reliability was good for the axillary recess, with ICC values of 0.84 for the coronal plane, and good for the rotator interval, with ICC values of 0.80 for the sagittal plane. MRI with IV Gd-chelate injection can show, with acceptable reliability, signal and thickness abnormalities of the shoulder joint capsule and synovial membrane in AC. (orig.)

  17. Magnetic resonance imaging of shoulders with idiopathic adhesive capsulitis: reliability of measures

    International Nuclear Information System (INIS)

    Lefevre-Colau, Marie-Martine; Fayad, Fouad; Rannou, Francois; Demaille-Wlodyka, Samantha; Mayoux-Benhamou, Marie-Anne; Poiraudeau, Serge; Revel, Michel; Drape, Jean-Luc; Diche, Thierry; Minvielle, Francois; Fermanian, Jacques

    2005-01-01

    The magnetic resonance imaging (MRI) findings in idiopathic adhesive capsulitis (AC) were compared with those of contralateral healthy shoulders and the reliability of measures assessed. Twenty-six consecutive patients (26 AC and 14 healthy shoulders) were prospectively assessed. The main measurements were thickness of the joint capsule and synovial membrane in the axillary recess and rotator interval in T1-weighted spin-echo sequence enhanced with intravenous (IV) gadolinium chelate (Gd-chelate). Reliability was studied by use of the intraclass correlation coefficient (ICC). The mean thickness of the axillary recess on the coronal plane was 9.0±2.2 mm in AC shoulders and 0.4±0.7 mm in healthy shoulders. The mean thickness of the rotator interval on the sagittal plane was 8.4±2.8 in AC shoulders and 0.6±0.8 mm in healthy shoulders. Interobserver reliability was good for the axillary recess, with ICC values of 0.84 for the coronal plane, and good for the rotator interval, with ICC values of 0.80 for the sagittal plane. MRI with IV Gd-chelate injection can show, with acceptable reliability, signal and thickness abnormalities of the shoulder joint capsule and synovial membrane in AC. (orig.)

  18. A reference data set for validating vapor pressure measurement techniques: homologous series of polyethylene glycols

    Science.gov (United States)

    Krieger, Ulrich K.; Siegrist, Franziska; Marcolli, Claudia; Emanuelsson, Eva U.; Gøbel, Freya M.; Bilde, Merete; Marsh, Aleksandra; Reid, Jonathan P.; Huisman, Andrew J.; Riipinen, Ilona; Hyttinen, Noora; Myllys, Nanna; Kurtén, Theo; Bannan, Thomas; Percival, Carl J.; Topping, David

    2018-01-01

    To predict atmospheric partitioning of organic compounds between gas and aerosol particle phase based on explicit models for gas phase chemistry, saturation vapor pressures of the compounds need to be estimated. Estimation methods based on functional group contributions require training sets of compounds with well-established saturation vapor pressures. However, vapor pressures of semivolatile and low-volatility organic molecules at atmospheric temperatures reported in the literature often differ by several orders of magnitude between measurement techniques. These discrepancies exceed the stated uncertainty of each technique which is generally reported to be smaller than a factor of 2. At present, there is no general reference technique for measuring saturation vapor pressures of atmospherically relevant compounds with low vapor pressures at atmospheric temperatures. To address this problem, we measured vapor pressures with different techniques over a wide temperature range for intercomparison and to establish a reliable training set. We determined saturation vapor pressures for the homologous series of polyethylene glycols (H - (O - CH2 - CH2)n - OH) for n = 3 to n = 8 ranging in vapor pressure at 298 K from 10-7 to 5×10-2 Pa and compare them with quantum chemistry calculations. Such a homologous series provides a reference set that covers several orders of magnitude in saturation vapor pressure, allowing a critical assessment of the lower limits of detection of vapor pressures for the different techniques as well as permitting the identification of potential sources of systematic error. Also, internal consistency within the series allows outlying data to be rejected more easily. Most of the measured vapor pressures agreed within the stated uncertainty range. Deviations mostly occurred for vapor pressure values approaching the lower detection limit of a technique. The good agreement between the measurement techniques (some of which are sensitive to the mass

  19. Reliability of ultrasound for measurement of selected foot structures.

    Science.gov (United States)

    Crofts, G; Angin, S; Mickle, K J; Hill, S; Nester, C J

    2014-01-01

    Understanding the relationship between the lower leg muscles, foot structures and function is essential to explain how disease or injury may relate to changes in foot function and clinical pathology. The aim of this study was to investigate the inter-operator reliability of an ultrasound protocol to quantify features of: rear, mid and forefoot sections of the plantar fascia (PF); flexor hallucis brevis (FHB); flexor digitorum brevis (FDB); abductor hallucis (AbH); flexor digitorum longus (FDL); flexor hallucis longus (FHL); tibialis anterior (TA); and peroneus longus and brevis (PER). A sample of 6 females and 4 males (mean age 29.1 ± 7.2 years, mean BMI 25.5 ± 4.8) was recruited from a university student and staff population. Scans were obtained using a portable Venue 40 musculoskeletal ultrasound system (GE Healthcare UK) with a 5-13 MHz wideband linear array probe with a 12.7 mm × 47.1mm footprint by two operators in the same scanning session. Intraclass Correlation Coefficients (ICC) values for muscle thickness (ICC range 0.90-0.97), plantar fascia thickness (ICC range 0.94-0.98) and cross sectional muscle measurements (ICC range 0.91-0.98) revealed excellent inter-operator reliability. The limits of agreement, relative to structure size, ranged from 9.0% to 17.5% for muscle thickness, 11.0-18.0% for plantar fascia, and 11.0-26.0% for cross sectional area measurements. The ultrasound protocol implemented in this work has been shown to be reliable. It therefore offers the opportunity to quantify the structures concerned and better understand their contributions to foot function. Crown Copyright © 2013. Published by Elsevier B.V. All rights reserved.

  20. Reliability and validity of the test of incremental respiratory endurance measures of inspiratory muscle performance in COPD.

    Science.gov (United States)

    Formiga, Magno F; Roach, Kathryn E; Vital, Isabel; Urdaneta, Gisel; Balestrini, Kira; Calderon-Candelario, Rafael A; Campos, Michael A; Cahalin, Lawrence P

    2018-01-01

    The Test of Incremental Respiratory Endurance (TIRE) provides a comprehensive assessment of inspiratory muscle performance by measuring maximal inspiratory pressure (MIP) over time. The integration of MIP over inspiratory duration (ID) provides the sustained maximal inspiratory pressure (SMIP). Evidence on the reliability and validity of these measurements in COPD is not currently available. Therefore, we assessed the reliability, responsiveness and construct validity of the TIRE measures of inspiratory muscle performance in subjects with COPD. Test-retest reliability, known-groups and convergent validity assessments were implemented simultaneously in 81 male subjects with mild to very severe COPD. TIRE measures were obtained using the portable PrO2 device, following standard guidelines. All TIRE measures were found to be highly reliable, with SMIP demonstrating the strongest test-retest reliability with a nearly perfect intraclass correlation coefficient (ICC) of 0.99, while MIP and ID clustered closely together behind SMIP with ICC values of about 0.97. Our findings also demonstrated known-groups validity of all TIRE measures, with SMIP and ID yielding larger effect sizes when compared to MIP in distinguishing between subjects of different COPD status. Finally, our analyses confirmed convergent validity for both SMIP and ID, but not MIP. The TIRE measures of MIP, SMIP and ID have excellent test-retest reliability and demonstrated known-groups validity in subjects with COPD. SMIP and ID also demonstrated evidence of moderate convergent validity and appear to be more stable measures in this patient population than the traditional MIP.

  1. Ammonia slip measurements on ships with NO{sub x} converters. A study of different techniques

    Energy Technology Data Exchange (ETDEWEB)

    Fridell, Erik; Steen, Erica (IVL, Goeteborg (SE))

    2007-12-15

    A number of techniques to measure the concentration of ammonia in exhaust gas have been evaluated. The objective is to obtain reliable methods for measuring ammonia slip from ships equipped with SCR systems for cleaning of nitrogen oxide emissions. The methods tested are FTIR, laser absorption, a wet chemical method and a method where ammonia is oxidised into NO{sub x} over a catalyst. The laser method is an in-situ technique, where the transmitter and receiver are positioned on opposite flanges at the exhaust channel, while the other methods are ex-situ, i. e., a probe volume of gas is taken from the exhaust channel into the instrumentation. The laser method worked well in the field studies and gave results with high sensitivity and good time resolution. FTIR did not work well for low concentrations. The time resolution is good but with a delay. In cases with an uneven distribution of ammonia throughout the exhaust channel, the concentration will vary depending on the location of the probe. A strong influence of the oxygen concentration on the observed ammonia concentration was found in the laboratory study. The wet chemical method gave reliable results. The time resolution is poor and the method is sensitive to uneven distribution in the exhaust channel. The method with the oxidation catalyst worked well in the lab but not in field where the catalyst was deactivated, probably by sulphur

  2. How to measure wisdom: content, reliability, and validity of five measures

    Science.gov (United States)

    Glück, Judith; König, Susanne; Naschenweng, Katja; Redzanowski, Uwe; Dorner, Lara; Straßer, Irene; Wiedermann, Wolfgang

    2013-01-01

    Wisdom is a field of growing interest both inside and outside academic psychology, and researchers are increasingly interested in using measures of wisdom in their work. However, wisdom is a highly complex construct, and its various operationalizations are based on quite different definitions. Which measure a researcher chooses for a particular research project may have a strong influence on the results. This study compares four well-established measures of wisdom—the Self-Assessed Wisdom Scale (Webster, 2003, 2007), the Three-Dimensional Wisdom Scale (Ardelt, 2003), the Adult Self-Transcendence Inventory (Levenson et al., 2005), and the Berlin Wisdom Paradigm (Baltes and Smith, 1990; Baltes and Staudinger, 2000)—with respect to content, reliability, factorial structure, and construct validity (relationships to wisdom nomination, interview-based wisdom ratings, and correlates of wisdom). The sample consisted of 47 wisdom nominees and 123 control participants. While none of the measures performed “better” than the others by absolute standards, recommendations are given for researchers to select the most suitable measure for their substantive interests. In addition, a “Brief Wisdom Screening Scale” is introduced that contains those 20 items from the three self-report scales that were most highly correlated with the common factor across the scales. PMID:23874310

  3. Reliability and Measurement Error of Tensiomyography to Assess Mechanical Muscle Function: A Systematic Review.

    Science.gov (United States)

    Martín-Rodríguez, Saúl; Loturco, Irineu; Hunter, Angus M; Rodríguez-Ruiz, David; Munguia-Izquierdo, Diego

    2017-12-01

    Martín-Rodríguez, S, Loturco, I, Hunter, AM, Rodríguez-Ruiz, D, and Munguia-Izquierdo, D. Reliability and measurement error of tensiomyography to assess mechanical muscle function: A systematic review. J Strength Cond Res 31(12): 3524-3536, 2017-Interest in studying mechanical skeletal muscle function through tensiomyography (TMG) has increased in recent years. This systematic review aimed to (a) report the reliability and measurement error of all TMG parameters (i.e., maximum radial displacement of the muscle belly [Dm], contraction time [Tc], delay time [Td], half-relaxation time [½ Tr], and sustained contraction time [Ts]) and (b) to provide critical reflection on how to perform accurate and appropriate measurements for informing clinicians, exercise professionals, and researchers. A comprehensive literature search was performed of the Pubmed, Scopus, Science Direct, and Cochrane databases up to July 2017. Eight studies were included in this systematic review. Meta-analysis could not be performed because of the low quality of the evidence of some studies evaluated. Overall, the review of the 9 studies involving 158 participants revealed high relative reliability (intraclass correlation coefficient [ICC]) for Dm (0.91-0.99); moderate-to-high ICC for Ts (0.80-0.96), Tc (0.70-0.98), and ½ Tr (0.77-0.93); and low-to-high ICC for Td (0.60-0.98), independently of the evaluated muscles. In addition, absolute reliability (coefficient of variation [CV]) was low for all TMG parameters except for ½ Tr (CV = >20%), whereas measurement error indexes were high for this parameter. In conclusion, this study indicates that 3 of the TMG parameters (Dm, Td, and Tc) are highly reliable, whereas ½ Tr demonstrate insufficient reliability, and thus should not be used in future studies.

  4. Research on reliability measures of the main transformer and GIS equipment manufacturing process

    International Nuclear Information System (INIS)

    Wu Honglong

    2014-01-01

    Based on the accidents of the main transformer GIS equipment and the accidents of the high voltage switch equipment, combined with the main transformer switch equipment maintenance experience and electrical theory, the reliability measures of the main transformer GIS equipment during manufacturing stage are studied and improved. Six successful reliability measures are identified: 1) design properly and check the ability of transformer for anti short circuit; 2) choose mature and reliable main transformer HV bushing; 3) choose GIS switch operation mechanism of high quality and reliability; 4) ensure that the insulation margin through tests piece by piece on withstand voltage and partial discharge of the GIS equipment insulation; 5) take test measures such as GIS conductor, shell polishing witness process and full form lightning impulse, to find out and eliminate the defects of abnormal electric field distribution; 6) Anti VFTO design for the main transformer connected with GIS with the voltage of 500 kV should be considered, and its anti VFTO ability to meet the safe operation under VFTO requirements should be checked. This paper proposed 2 new measures: 1) the main transformer insulation material quality standard is determined not only by its high dielectric strength, but more importantly by the homogeneous dielectric electric strength. Insulating Materials with a high and also uniform dielectric strength should be chosen. 2) During the silver-coating stage of the GIS equipment conductor, QC group activities should be organized to ensure that the plating layer quality, and the current lap surface DC resistance measurements should be supervised and witnessed to ensure the quality of the conductor contact surface. These measures are verified in Fuqing project of GIS main transformer equipment manufacturing process, and their effectiveness is proven. (author)

  5. Blower-door techniques for measuring interzonal leakage

    Energy Technology Data Exchange (ETDEWEB)

    Hult, Erin L.; Sherman, Max H.; Walker, Iain

    2013-01-01

    Abstract The standard blower door test methods, such as ASTM E779, describe how to use a single blower door to determine the total leakage of a single-zone structure such as a detached single-family home. There are no standard test methods for measuring interzonal leakage in a two-zone or multi-zone building envelope such as might be encountered in with an attached garage or in a multifamily building. Some practitioners have been using techniques that involve making multiple measurements with a single blower door as well as combined measurements using multiple blower doors. Even for just two zones there are dozens of combinations of one-door and two-door test protocols that could conceivably be used to determine the interzonal air tightness. We examined many of these two-zone configurations using both simulation and measured data to estimate the accuracy and precision of each technique for realistic measurement scenarios. We also considered the impact of taking measurements at a single pressure versus over multiple pressures. We compared the various techniques and evaluated them for specific uses. Some techniques work better in one leakage regime; some are more sensitive to wind and other noise; some are more suited to determining only a subset of the leakage values. This paper makes recommendations on which techniques to use or not use for various cases and provides data that could be used to develop future test methods.

  6. Measurements Techniques for Gyrotron characterization

    International Nuclear Information System (INIS)

    Castro, P.J. de.

    1987-08-01

    Experiments planned for the characterization of the 35GHz girotron, which is being built at the Plasma Laboratory of INPE, are described. The methods of the measurements are presented and the required instrumentation and devices are specified. Special attention is given to the measurement techniques of the resonator electric field profile. (author) [pt

  7. Reliability and Validity of Selected PROMIS Measures in People with Rheumatoid Arthritis.

    Directory of Open Access Journals (Sweden)

    Susan J Bartlett

    Full Text Available To evaluate the reliability and validity of 11 PROMIS measures to assess symptoms and impacts identified as important by people with rheumatoid arthritis (RA.Consecutive patients (N = 177 in an observational study completed PROMIS computer adapted tests (CATs and a short form (SF assessing pain, fatigue, physical function, mood, sleep, and participation. We assessed test-test reliability and internal consistency using correlation and Cronbach's alpha. We assessed convergent validity by examining Pearson correlations between PROMIS measures and existing measures of similar domains and known groups validity by comparing scores across disease activity levels using ANOVA.Participants were mostly female (82% and white (83% with mean (SD age of 56 (13 years; 24% had ≤ high school, 29% had RA ≤ 5 years with 13% ≤ 2 years, and 22% were disabled. PROMIS Physical Function, Pain Interference and Fatigue instruments correlated moderately to strongly (rho's ≥ 0.68 with corresponding PROs. Test-retest reliability ranged from .725-.883, and Cronbach's alpha from .906-.991. A dose-response relationship with disease activity was evident in Physical Function with similar trends in other scales except Anger.These data provide preliminary evidence of reliability and construct validity of PROMIS CATs to assess RA symptoms and impacts, and feasibility of use in clinical care. PROMIS instruments captured the experiences of RA patients across the broad continuum of RA symptoms and function, especially at low disease activity levels. Future research is needed to evaluate performance in relevant subgroups, assess responsiveness and identify clinically meaningful changes.

  8. Assessment of intra-interobserver reliability of the sonographic optic nerve sheath diameter measurement

    Directory of Open Access Journals (Sweden)

    Tuba Cimilli Ozturk

    2015-08-01

    Full Text Available Diagnosis and measuring the level of increase in intracranial pressure (ICP is critical, especially for the management of trauma patients in the emergency department and intensive care unit. However, measurements are operator-dependent as in all of the sonographic diagnoses. The aim of this study is to assess the operator variations in the measurement of optic nerve sheath diameter (ONSD. There were four emergency medicine specialists involved in the study. Each had at least 1 year of experience of ultrasound scans and performed at least 25 prior ocular scans examining the ONSD. Two measurements were made 1 week apart from both axial and longitudinal planes. Sixty healthy adults were involved in the study and every investigator obtained four measurements from each. Intra-interobserver reliabilities were tested. The investigators performed 60 ocular ultrasounds on individual healthy adults and obtained two measurements in axial and longitudinal planes 1 week apart. Therefore, 960 measurements were analyzed. The levels of compatibilities for most of the measurements were found at acceptable levels statistically. However, it is not possible to say that there was a perfect compatibility among the sonographers according to the previously conducted reliability studies of ultrasound measurements. According to our results, it is hard to say that sonographic measurement of the ONSD is a highly reliable method both in longitudinal and transverse planes.

  9. Some areas of reliability technique which have been neglected to some extent - maintainability - human reliability - mechanical reliability - repairable systems

    International Nuclear Information System (INIS)

    Akersten, P.A.

    1985-01-01

    The present thesis consists of four papers, three of which are of a expositary nature and one more theoretical. The first two papers have a natural coupling to the man-machine interface. The first paper is devoted to the concept of maintainability and the role of man as maintenance technician. The second paper discusses aspects of human reliability, mainly studying man as operator. However, maintenance tasks can be studied in the same manner. The third paper concerns reliability prediction for mechanical components. This is an area of vital importance for the reliability practitioner, who needs realistic and easy-to-use mathematical models for different failure modes. The fourth paper discusses mathematical models for repairable systems, especially the problem of testing whether a constant event intensity model is adequate or not. (author)

  10. Test-Retest Reliability of Isokinetic Knee Strength Measurements in Children Aged 8 to 10 Years.

    Science.gov (United States)

    Fagher, Kristina; Fritzson, Annelie; Drake, Anna Maria

    Isokinetic dynamometry is a useful tool to objectively assess muscle strength of children and adults in athletic and rehabilitative settings. This study examined test-retest reliability of isokinetic knee strength measurements in children aged 8 to 10 years and defined limits for the minimum difference (MD) in strength that indicates a clinically important change. Isokinetic knee strength measurements (using the Biodex System 4) in children will provide reliable results. Descriptive laboratory study. In 22 healthy children, 5 maximal concentric (CON) knee extensor (KE) and knee flexor (KF) contractions at 2 angular velocities (60 deg/s and 180 deg/s) and 5 maximal eccentric (ECC) KE/KF contractions at 60 deg/s were assessed 7 days apart. The intraclass correlation coefficient (ICC 2.1 ) was used to examine relative reliability, and the MD was calculated on the basis of standard error of measurement. ICCs for CON KE/KF peak torque measurements were fair to excellent (range, 0.49-0.81). The MD% values for CON KE and KF ranged from 31% to 37% at 60 deg/s and from 34% to 39% at 180 deg/s. ICCs in the ECC mode were good (range, 0.60-0.70), but associated MD% values were high (>50%). There was no systematic error for CON KE/KF and ECC KE strength measurements at 60 deg/s, but systematic error was found for all other measurements. The dynamometer provides a reliable analysis of isokinetic CON knee strength measurements at 60 deg/s in children aged 8 to 10 years. Measurements at 180 deg/s and in the ECC mode were not reliable, indicating a need for more familiarization prior to testing. The MD values may help clinicians to determine whether a change in knee strength is due to error or intervention.

  11. Reliability of Pressure Ulcer Rates: How Precisely Can We Differentiate Among Hospital Units, and Does the Standard Signal‐Noise Reliability Measure Reflect This Precision?

    Science.gov (United States)

    Cramer, Emily

    2016-01-01

    Abstract Hospital performance reports often include rankings of unit pressure ulcer rates. Differentiating among units on the basis of quality requires reliable measurement. Our objectives were to describe and apply methods for assessing reliability of hospital‐acquired pressure ulcer rates and evaluate a standard signal‐noise reliability measure as an indicator of precision of differentiation among units. Quarterly pressure ulcer data from 8,199 critical care, step‐down, medical, surgical, and medical‐surgical nursing units from 1,299 US hospitals were analyzed. Using beta‐binomial models, we estimated between‐unit variability (signal) and within‐unit variability (noise) in annual unit pressure ulcer rates. Signal‐noise reliability was computed as the ratio of between‐unit variability to the total of between‐ and within‐unit variability. To assess precision of differentiation among units based on ranked pressure ulcer rates, we simulated data to estimate the probabilities of a unit's observed pressure ulcer rate rank in a given sample falling within five and ten percentiles of its true rank, and the probabilities of units with ulcer rates in the highest quartile and highest decile being identified as such. We assessed the signal‐noise measure as an indicator of differentiation precision by computing its correlations with these probabilities. Pressure ulcer rates based on a single year of quarterly or weekly prevalence surveys were too susceptible to noise to allow for precise differentiation among units, and signal‐noise reliability was a poor indicator of precision of differentiation. To ensure precise differentiation on the basis of true differences, alternative methods of assessing reliability should be applied to measures purported to differentiate among providers or units based on quality. © 2016 The Authors. Research in Nursing & Health published by Wiley Periodicals, Inc. PMID:27223598

  12. Experimental techniques of conversion coefficient measurements

    International Nuclear Information System (INIS)

    Hamilton, J.H.

    1975-01-01

    Discusses briefly the history of conversion electron spectra measurements, and the interpretation of the collected data. Then provides a comprehensive review of techniques presently available to measure the conversion coefficients. (Auth.)

  13. Ground-based intercomparison of two isoprene measurement techniques

    Directory of Open Access Journals (Sweden)

    E. Leibrock

    2003-01-01

    Full Text Available An informal intercomparison of two isoprene (C5H8 measurement techniques was carried out during Fall of 1998 at a field site located approximately 3 km west of Boulder, Colorado, USA. A new chemical ionization mass spectrometric technique (CIMS was compared to a well-established gas chromatographic technique (GC. The CIMS technique utilized benzene cation chemistry to ionize isoprene. The isoprene levels measured by the CIMS were often larger than those obtained with the GC. The results indicate that the CIMS technique suffered from an anthropogenic interference associated with air masses from the Denver, CO metropolitan area as well as an additional interference occurring in clean conditions. However, the CIMS technique is also demonstrated to be sensitive and fast. Especially after introduction of a tandem mass spectrometric technique, it is therefore a candidate for isoprene measurements in remote environments near isoprene sources.

  14. Spectrometry techniques for radioactivity measurements

    International Nuclear Information System (INIS)

    Anilkumar, S.

    2016-01-01

    The energy of the radiation emission following the nuclear decay is unique and the characteristic of the radio nuclide which undergoes decay. Thus measurement of the energy of the radiation offers a method of identifying the radio nuclides. The prime requirement of the energy measurement is a suitable detector which shows response proportional to the energy of the radiation rather than the presence of the radiation. The response from such detectors are suitably processed and distributed with respect to the signal strength which is proportional to incident energy. This distribution is normally referred as energy spectrum and is recorded in the multichannel analyser. The measurement of energy and intensity of radiation from the spectrum is called radiation spectrometry. Thus the radiation spectrometry allows the identification and quantification of radioactive isotopes in variety of matrices. The radiation spectrometry has now become a popular radioanalytical technique in wide area of nuclear fuel cycle programs. The popular spectrometry techniques commonly used for the radioactivity measurement and analysis are Alpha spectrometry, Gamma ray spectrometry and Beta spectrometry

  15. Reliability

    OpenAIRE

    Condon, David; Revelle, William

    2017-01-01

    Separating the signal in a test from the irrelevant noise is a challenge for all measurement. Low test reliability limits test validity, attenuates important relationships, and can lead to regression artifacts. Multiple approaches to the assessment and improvement of reliability are discussed. The advantages and disadvantages of several different approaches to reliability are considered. Practical advice on how to assess reliability using open source software is provided.

  16. Measuring the airway in 3 dimensions: a reliability and accuracy study.

    Science.gov (United States)

    El, Hakan; Palomo, Juan Martin

    2010-04-01

    The aim of the study was to compare the reliability and accuracy of 3 commercially available digital imaging and communications in medicine (DICOM) viewers for measuring upper airway volumes. Thirty cone-beam computed tomography scans were randomly selected, and the upper airway volumes were calculated for both oropharynx and nasal passage. Dolphin3D (version 11, Dolphin Imaging & Management Solutions, Chatsworth, Calif), InVivoDental (version 4.0.70, Anatomage, San Jose, Calif), and OnDemand3D (version 1.0.1.8407, CyberMed, Seoul, Korea) were compared with a previously tested manual segmentation program called OrthoSegment (OS) (developed at the Department of Orthodontics at Case Western Reserve University, Cleveland, Ohio). The measurements were repeated after 2 weeks, and the ICC was used for the reliability tests. All commercially available programs were compared with the OS program by using regression analysis. The Pearson correlation was used to evaluate the correlation between the OS and the automatic segmentation programs. The reliability was high for all programs. The highest correlation found was between the OS and Dolphin3D for the oropharynx, and between the OS and InVivoDental for nasal passage volume. A high correlation was found for all programs, but the results also showed statistically significant differences compared with the OS program. The programs also had inconsistencies among themselves. The 3 commercially available DICOM viewers are highly reliable in their airway volume calculations and showed high correlation of results but poor accuracy, suggesting systematic errors. Copyright 2010 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.

  17. A Review on VSC-HVDC Reliability Modeling and Evaluation Techniques

    Science.gov (United States)

    Shen, L.; Tang, Q.; Li, T.; Wang, Y.; Song, F.

    2017-05-01

    With the fast development of power electronics, voltage-source converter (VSC) HVDC technology presents cost-effective ways for bulk power transmission. An increasing number of VSC-HVDC projects has been installed worldwide. Their reliability affects the profitability of the system and therefore has a major impact on the potential investors. In this paper, an overview of the recent advances in the area of reliability evaluation for VSC-HVDC systems is provided. Taken into account the latest multi-level converter topology, the VSC-HVDC system is categorized into several sub-systems and the reliability data for the key components is discussed based on sources with academic and industrial backgrounds. The development of reliability evaluation methodologies is reviewed and the issues surrounding the different computation approaches are briefly analysed. A general VSC-HVDC reliability evaluation procedure is illustrated in this paper.

  18. Reliability of agriculture universal joint shafts based on temperature measuring in universal joint bearing assemblies

    Directory of Open Access Journals (Sweden)

    Аleksandar Asonja

    2015-03-01

    Full Text Available This paper presents a research into reliability calculations of agriculture double universal joint shafts based on temperature measuring in cardan-type universal joint bearing assemblies. Special laboratory equipment was developed for this research which is presented in the paper. The objective of this research was to test the real life span of universal joint shafts in the laboratory and in field, to obtain the results which can be used to improve the reliability of universal joint shafts. If the presented research were used along with maintenance measures recommended in the paper and with proper use, the level of reliability of the shafts would be 2.1 times higher. The presented results of the research showed that needle bearings, i.e. bearing assemblies of the joints, are the most critical elements on universal joint shafts and are possible causes of their lower reliability. The second universal joint is the part with the lowest reliability in the observed technical system.

  19. Harmonization process and reliability assessment of anthropometric measurements in the elderly EXERNET multi-centre study.

    Directory of Open Access Journals (Sweden)

    Alba Gómez-Cabello

    Full Text Available BACKGROUND: The elderly EXERNET multi-centre study aims to collect normative anthropometric data for old functionally independent adults living in Spain. PURPOSE: To describe the standardization process and reliability of the anthropometric measurements carried out in the pilot study and during the final workshop, examining both intra- and inter-rater errors for measurements. MATERIALS AND METHODS: A total of 98 elderly from five different regions participated in the intra-rater error assessment, and 10 different seniors living in the city of Toledo (Spain participated in the inter-rater assessment. We examined both intra- and inter-rater errors for heights and circumferences. RESULTS: For height, intra-rater technical errors of measurement (TEMs were smaller than 0.25 cm. For circumferences and knee height, TEMs were smaller than 1 cm, except for waist circumference in the city of Cáceres. Reliability for heights and circumferences was greater than 98% in all cases. Inter-rater TEMs were 0.61 cm for height, 0.75 cm for knee-height and ranged between 2.70 and 3.09 cm for the circumferences measured. Inter-rater reliabilities for anthropometric measurements were always higher than 90%. CONCLUSION: The harmonization process, including the workshop and pilot study, guarantee the quality of the anthropometric measurements in the elderly EXERNET multi-centre study. High reliability and low TEM may be expected when assessing anthropometry in elderly population.

  20. Validity and Reliability of Dynamic Visual Acuity (DVA) Measurement During Walking

    Science.gov (United States)

    Deshpande, Nandini; Peters, Brian T.; Bloomberg, Jacob J.

    2014-01-01

    DVA is primarily subserved by the vestibulo-ocular reflex mechanism. Individuals with vestibular hypofunction commonly experience highly debilitating illusory movement or blurring of visual images during daily activities possibly, due to impaired DVA. Even without pathologies, gradual age-related morphological deterioration is evident in all components of the vestibular system. We examined the construct validity to detect age-related differences and test-retest reliability of DVA measurements performed during walking. METHODS: Healthy adults were recruited into 3 groups: 1. young (20-39years, n=18), 2. middle-aged (40-59years, n=14), and 3. older adults (60-80years, n=15). Randomly selected seven participants from each group (n=21) participated in retesting. Participants were excluded if they had a history of vestibular or neuromuscular pathologies, dizziness/vertigo or >1 falls in the past year. Older persons with MMSE scores reliability. RESULTS: The three age groups were not different in their height, weight and normal walking speed (p>0.05). The post hoc analyses for DVA measurements demonstrated that each group was significantly different from the other two groups for Near as well as FarDVA (preliability. FarDVA at 0.8 m/s and 1.0 m/s demonstrated good test-retest reliability (ICCs 0.71 and 0.77, respectively).

  1. Research review and development trends of human reliability analysis techniques

    International Nuclear Information System (INIS)

    Li Pengcheng; Chen Guohua; Zhang Li; Dai Licao

    2011-01-01

    Human reliability analysis (HRA) methods are reviewed. The theoretical basis of human reliability analysis, human error mechanism, the key elements of HRA methods as well as the existing HRA methods are respectively introduced and assessed. Their shortcomings,the current research hotspot and difficult problems are identified. Finally, it takes a close look at the trends of human reliability analysis methods. (authors)

  2. Reliability and responsiveness of a goniometric device for measuring the range of motion in the dart-throwing motion plane.

    Science.gov (United States)

    Kasubuchi, Kenji; Dohi, Yoshihiro; Fujita, Hiroyuki; Fukumoto, Takahiko

    2018-02-26

    Dart-throwing motion (DTM) is an important component of wrist function and, consequently, has the potential to become an evaluation tool in rehabilitation. However, no measurement method is currently available to reliably measure range of motion (ROM) of the wrist in the DTM plane. To determine the reliability and responsiveness of a goniometric device to measure wrist ROM in the DTM plane. ROM of the wrist in the DTM plane was measured in 70 healthy participants. The intra-class correlation coefficient (ICC) was used to evaluate the relative reliability of measurement, and a Bland-Altman analysis conducted to establish its absolute reliability, including the 95% limits of agreement (95% LOA). The standard error of the measurement (SEM) and minimal detectable change at the 95% confidence level (MDC 95 ) were calculated as measures of responsiveness. The intra-rater ICC was 0.87, and an inter-rater ICC of 0.71. There was no evidence of a fixed or proportional bias. For intra- and inter-rater reliability, 95% LOA ranged from -13.83 to 11.12 and from -17.75 to 16.19, respectively. The SEM and MDC 95 were 4.5° and 12.4°, respectively, for intra-rater reliability, and 6.0° and 16.6°, respectively, for inter-rater reliability. The ROM of the wrist in the DTM plane was measured with fair-to-good reliability and responsiveness and, therefore, has the potential to become an evaluation tool for rehabilitation.

  3. Fatigue is a reliable, sensitive and unique outcome measure in rheumatoid arthritis.

    LENUS (Irish Health Repository)

    Minnock, Patricia

    2009-12-01

    Fatigue is an important symptom in patients with RA. Measurement of fatigue in clinical trials and in clinical practice requires scales that are reproducible, sensitive to change and practical. This study examined the reliability and sensitivity to change of fatigue and its relative independence as an outcome measure in RA.

  4. Adaptive Response Surface Techniques in Reliability Estimation

    DEFF Research Database (Denmark)

    Enevoldsen, I.; Faber, M. H.; Sørensen, John Dalsgaard

    1993-01-01

    Problems in connection with estimation of the reliability of a component modelled by a limit state function including noise or first order discontinuitics are considered. A gradient free adaptive response surface algorithm is developed. The algorithm applies second order polynomial surfaces...

  5. Measurement techniques for radio frequency nanoelectronics

    CERN Document Server

    Wallis, T Mitch

    2017-01-01

    Connect basic theory with real-world applications with this practical, cross-disciplinary guide to radio frequency measurement of nanoscale devices and materials.• Learn the techniques needed for characterizing the performance of devices and their constituent building blocks, including semiconducting nanowires, graphene, and other two dimensional materials such as transition metal dichalcogenides• Gain practical insights into instrumentation, including on-wafer measurement platforms and scanning microwave microscopy• Discover how measurement techniques can be applied to solve real-world problems, in areas such as passive and active nanoelectronic devices, semiconductor dopant profiling, subsurface nanoscale tomography, nanoscale magnetic device engineering, and broadband, spatially localized measurements of biological materialsFeaturing numerous practical examples, and written in a concise yet rigorous style, this is the ideal resource for researchers, practicing engineers, and graduate students new to ...

  6. Reliability and validity of an internet-based questionnaire measuring lifetime physical activity.

    Science.gov (United States)

    De Vera, Mary A; Ratzlaff, Charles; Doerfling, Paul; Kopec, Jacek

    2010-11-15

    Lifetime exposure to physical activity is an important construct for evaluating associations between physical activity and disease outcomes, given the long induction periods in many chronic diseases. The authors' objective in this study was to evaluate the measurement properties of the Lifetime Physical Activity Questionnaire (L-PAQ), a novel Internet-based, self-administered instrument measuring lifetime physical activity, among Canadian men and women in 2005-2006. Reliability was examined using a test-retest study. Validity was examined in a 2-part study consisting of 1) comparisons with previously validated instruments measuring similar constructs, the Lifetime Total Physical Activity Questionnaire (LT-PAQ) and the Chasan-Taber Physical Activity Questionnaire (CT-PAQ), and 2) a priori hypothesis tests of constructs measured by the L-PAQ. The L-PAQ demonstrated good reliability, with intraclass correlation coefficients ranging from 0.67 (household activity) to 0.89 (sports/recreation). Comparison between the L-PAQ and the LT-PAQ resulted in Spearman correlation coefficients ranging from 0.41 (total activity) to 0.71 (household activity); comparison between the L-PAQ and the CT-PAQ yielded coefficients of 0.58 (sports/recreation), 0.56 (household activity), and 0.50 (total activity). L-PAQ validity was further supported by observed relations between the L-PAQ and sociodemographic variables, consistent with a priori hypotheses. Overall, the L-PAQ is a useful instrument for assessing multiple domains of lifetime physical activity with acceptable reliability and validity.

  7. The reliability of a severity rating scale to measure stuttering in an unfamiliar language.

    Science.gov (United States)

    Hoffman, Laura; Wilson, Linda; Copley, Anna; Hewat, Sally; Lim, Valerie

    2014-06-01

    With increasing multiculturalism, speech-language pathologists (SLPs) are likely to work with stuttering clients from linguistic backgrounds that differ from their own. No research to date has estimated SLPs' reliability when measuring severity of stuttering in an unfamiliar language. Therefore, this study was undertaken to estimate the reliability of SLPs' use of a 9-point severity rating (SR) scale, to measure severity of stuttering in a language that was different from their own. Twenty-six Australian SLPs rated 20 speech samples (10 Australian English [AE] and 10 Mandarin) of adults who stutter using a 9-point SR scale on two separate occasions. Judges showed poor agreement when using the scale to measure stuttering in Mandarin samples. Results also indicated that 50% of individual judges were unable to reliably measure the severity of stuttering in AE. The results highlight the need for (a) SLPs to develop intra- and inter-judge agreement when using the 9-point SR scale to measure severity of stuttering in their native language (in this case AE) and in unfamiliar languages; and (b) research into the development and evaluation of practice and/or training packages to assist SLPs to do so.

  8. Solar Cell Calibration and Measurement Techniques

    Science.gov (United States)

    Bailey, Sheila; Brinker, Dave; Curtis, Henry; Jenkins, Phillip; Scheiman, Dave

    2004-01-01

    The increasing complexity of space solar cells and the increasing international markets for both cells and arrays has resulted in workshops jointly sponsored by NASDA, ESA and NASA. These workshops are designed to obtain international agreement on standardized values for the AMO spectrum and constant, recommend laboratory measurement practices and establish a set of protocols for international comparison of laboratory measurements. A working draft of an ISO standard, WD15387, "Requirements for Measurement and Calibration Procedures for Space Solar Cells" was discussed with a focus on the scope of the document, a definition of primary standard cell, and required error analysis for all measurement techniques. Working groups addressed the issues of Air Mass Zero (AMO) solar constant and spectrum, laboratory measurement techniques, and te international round robin methodology. A summary is presented of the current state of each area and the formulation of the ISO document.

  9. Neutron flux measurement utilizing Campbell technique

    International Nuclear Information System (INIS)

    Kropik, M.

    2000-01-01

    Application of the Campbell technique for the neutron flux measurement is described in the contribution. This technique utilizes the AC component (noise) of a neutron chamber signal rather than a usually used DC component. The Campbell theorem, originally discovered to describe noise behaviour of valves, explains that the root mean square of the AC component of the chamber signal is proportional to the neutron flux (reactor power). The quadratic dependence of the reactor power on the root mean square value usually permits to accomplish the whole current power range of the neutron flux measurement by only one channel. Further advantage of the Campbell technique is that large pulses of the response to neutrons are favoured over small pulses of the response to gamma rays in the ratio of their mean square charge transfer and thus, the Campbell technique provides an excellent gamma rays discrimination in the current operational range of a neutron chamber. The neutron flux measurement channel using state of the art components was designed and put into operation. Its linearity, accuracy, dynamic range, time response and gamma discrimination were tested on the VR-1 nuclear reactor in Prague, and behaviour under high neutron flux (accident conditions) was tested on the TRIGA nuclear reactor in Vienna. (author)

  10. Thermal measurements and inverse techniques

    CERN Document Server

    Orlande, Helcio RB; Maillet, Denis; Cotta, Renato M

    2011-01-01

    With its uncommon presentation of instructional material regarding mathematical modeling, measurements, and solution of inverse problems, Thermal Measurements and Inverse Techniques is a one-stop reference for those dealing with various aspects of heat transfer. Progress in mathematical modeling of complex industrial and environmental systems has enabled numerical simulations of most physical phenomena. In addition, recent advances in thermal instrumentation and heat transfer modeling have improved experimental procedures and indirect measurements for heat transfer research of both natural phe

  11. A reliable ground bounce noise reduction technique for nanoscale CMOS circuits

    Science.gov (United States)

    Sharma, Vijay Kumar; Pattanaik, Manisha

    2015-11-01

    Power gating is the most effective method to reduce the standby leakage power by adding header/footer high-VTH sleep transistors between actual and virtual power/ground rails. When a power gating circuit transitions from sleep mode to active mode, a large instantaneous charge current flows through the sleep transistors. Ground bounce noise (GBN) is the high voltage fluctuation on real ground rail during sleep mode to active mode transitions of power gating circuits. GBN disturbs the logic states of internal nodes of circuits. A novel and reliable power gating structure is proposed in this article to reduce the problem of GBN. The proposed structure contains low-VTH transistors in place of high-VTH footer. The proposed power gating structure not only reduces the GBN but also improves other performance metrics. A large mitigation of leakage power in both modes eliminates the need of high-VTH transistors. A comprehensive and comparative evaluation of proposed technique is presented in this article for a chain of 5-CMOS inverters. The simulation results are compared to other well-known GBN reduction circuit techniques at 22 nm predictive technology model (PTM) bulk CMOS model using HSPICE tool. Robustness against process, voltage and temperature (PVT) variations is estimated through Monte-Carlo simulations.

  12. Liquidus temperature and optical properties measurement by containerless techniques

    Science.gov (United States)

    Anderson, Collin D.

    1993-01-01

    Reactive alloy liquidus temperatures measured by conventional, contained techniques are often in error due to reactions with containers and gaseous impurities. This paper describes a new liquidus temperature measurement technique that avoids these problems by employing containerless processing. This technique relies on precise and accurate noncontact temperature measurements (NCTM), which are made possible by spectral emissivity values. The spectral emissivities, epsilon(sub lambda), are measured along with the optical properties (real, n, and imaginary, k, components of the index of refraction) using polarimetric techniques on electromagnetically levitated specimens. Results from work done at Vanderbilt University and Intersonics on the Ti-Al system are presented to demonstrate the above techniques.

  13. Relating measurement invariance, cross-level invariance, and multilevel reliability

    OpenAIRE

    Jak, S.; Jorgensen, T.D.

    2017-01-01

    Data often have a nested, multilevel structure, for example when data are collected from children in classrooms. This kind of data complicate the evaluation of reliability and measurement invariance, because several properties can be evaluated at both the individual level and the cluster level, as well as across levels. For example, cross-level invariance implies equal factor loadings across levels, which is needed to give latent variables at the two levels a similar interpretation. Reliabili...

  14. Development of Measurement Techniques For Strengthening Nuclear Safeguards

    International Nuclear Information System (INIS)

    Badawy, I.

    2007-01-01

    The strategy of nuclear safeguards is based on the accounting and control of nuclear materials, nuclear technologies and activities in a State in order to attain its ''Legal'' goals of the application of atomic energy. The present paper investigates the development in the measurement techniques used in the verification and control of NMs for the purpose of strengthening safeguards. Its focus is to review the recent nuclear measurement techniques used for the identification and verification of nuclear materials.The different levels of verification and the accuracy of these techniques are discussed. The implementation of stregthened safeguards; and nuclear materials verification and control in the world are mentioned. Also, the recently proposed measures to enhance the ability to detect undeclared nuclear materials, nuclear activities and facilities that would need advanced measurement techniques are indicated.

  15. Reliability of Eustachian tube function measurements in a hypobaric and hyperbaric pressure chamber.

    Science.gov (United States)

    Meyer, M F; Jansen, S; Mordkovich, O; Hüttenbrink, K-B; Beutner, D

    2017-12-01

    Measurement of the Eustachian tube (ET) function is a challenge. The demand for a precise and meaningful diagnostic tool increases-especially because more and more operative therapies are being offered without objective evidence. The measurement of the ET function by continuous impedance recording in a pressure chamber is an established method, although the reliability of the measurements is still unclear. Twenty-five participants (50 ears) were exposed to phases of compression and decompression in a hypo- and hyperbaric pressure chamber. The ET function reflecting parameters-ET opening pressure (ETOP), ET opening duration (ETOD) and ET opening frequency (ETOF)-were determined under exactly the same preconditions three times in a row. The intraclass correlation coefficient (ICC) and Bland and Altman plot were used to assess test-retest reliability. ICCs revealed a high correlation for ETOP and ETOF in phases of decompression (passive equalisation) as well as ETOD and ETOP in phases of compression (active induced equalisation). Very high correlation could be shown for ETOD in decompression and ETOF in compression phases. The Bland and Altman graphs could show that measurements provide results within a 95 % confidence interval in compression and decompression phases. We conclude that measurements in a pressure chamber are a very valuable tool in terms of estimating the ET opening and closing function. Measurements show some variance comparing participants, but provide reliable results within a 95 % confidence interval in retest. This study is the basis for enabling efficacy measurements of ET treatment modalities. © 2017 John Wiley & Sons Ltd.

  16. VALUATION TECHNIQUES USED IN FAIR VALUE MEASUREMENT

    Directory of Open Access Journals (Sweden)

    Cristina-Aurora, BUNEA-BONTAS

    2013-12-01

    Full Text Available Valuation of assets and liabilities involves significant judgements and estimates, especially when fair value measurement is required. Currently, IFRS 13 Fair Value Measurement offers a single and more comprehensive source of guidance that is applied to almost all fair value estimates. When measuring fair value of fixed assets, intangible assets, specified financial assets or liabilities, different valuation techniques may be used: the market approach, the cost approach and the income approach. This article reviews these techniques and points out that different valuation practices may provide different results depending on the item being fair valued and on the inputs used. Also it emphasizes that, in particular circumstances, there is the possibility that a certain technique may be more appropriate than other.

  17. The Reliability and Validity of Discrete and Continuous Measures of Psychopathology: A Quantitative Review

    Science.gov (United States)

    Markon, Kristian E.; Chmielewski, Michael; Miller, Christopher J.

    2011-01-01

    In 2 meta-analyses involving 58 studies and 59,575 participants, we quantitatively summarized the relative reliability and validity of continuous (i.e., dimensional) and discrete (i.e., categorical) measures of psychopathology. Overall, results suggest an expected 15% increase in reliability and 37% increase in validity through adoption of a…

  18. Critical spare parts ordering decisions using conditional reliability and stochastic lead time

    International Nuclear Information System (INIS)

    Godoy, David R.; Pascual, Rodrigo; Knights, Peter

    2013-01-01

    Asset-intensive companies face great pressure to reduce operation costs and increase utilization. This scenario often leads to over-stress on critical equipment and its spare parts associated, affecting availability, reliability, and system performance. As these resources impact considerably on financial and operational structures, the opportunity is given by demand for decision-making methods for the management of spare parts processes. We proposed an ordering decision-aid technique which uses a measurement of spare performance, based on the stress–strength interference theory; which we have called Condition-Based Service Level (CBSL). We focus on Condition Managed Critical Spares (CMS), namely, spares which are expensive, highly reliable, with higher lead times, and are not available in store. As a mitigation measure, CMS are under condition monitoring. The aim of the paper is orienting the decision time for CMS ordering or just continuing the operation. The paper presents a graphic technique which considers a rule for decision based on both condition-based reliability function and a stochastic/fixed lead time. For the stochastic lead time case, results show that technique is effective to determine the time when the system operation is reliable and can withstand the lead time variability, satisfying a desired service level. Additionally, for the constant lead time case, the technique helps to define insurance spares. In conclusion, presented ordering decision rule is useful to asset managers for enhancing the operational continuity affected by spare parts

  19. Strength Measurements in Acute Hamstring Injuries: Intertester Reliability and Prognostic Value of Handheld Dynamometry.

    Science.gov (United States)

    Reurink, Gustaaf; Goudswaard, Gert Jan; Moen, Maarten H; Tol, Johannes L; Verhaar, Jan A N; Weir, Adam

    2016-08-01

    Study Design Cohort study, repeated measures. Background Although hamstring strength measurements are used for assessing prognosis and monitoring recovery after hamstring injury, their actual clinical relevance has not been established. Handheld dynamometry (HHD) is a commonly used method of measuring muscle strength. The reliability of HHD has not been determined in athletes with acute hamstring injuries. Objectives To determine the intertester reliability and the prognostic value of hamstring HHD strength measurement in acute hamstring injuries. Methods We measured knee flexion strength with HHD in 75 athletes at 2 visits, at baseline (within 5 days of hamstring injury) and follow-up (5 to 7 days after the baseline measurement). We assessed isometric hamstring strength in 15° and 90° of knee flexion. Reliability analysis testing was performed by 2 testers independently at the follow-up visit. We recorded the time needed to return to play (RTP) up to 6 months following baseline. Results The intraclass correlation coefficients of the strength measurements in injured hamstrings were between 0.75 and 0.83. There was a statistically significant but weak correlation between the time to RTP and the strength deficit at 15° of knee flexion measured at baseline (Spearman r = 0.25, P = .045) and at the follow-up visit (Spearman r = 0.26, P = .034). Up to 7% of the variance in time to RTP is explained by this strength deficit. None of the other strength variables were significantly correlated with time to RTP. Conclusion Hamstring strength can be reliably measured with HHD in athletes with acute hamstring injuries. The prognostic value of strength measurements is limited, as there is only a weak association between the time to RTP and hamstring strength deficit after acute injury. Level of Evidence Prognosis, level 4. J Orthop Sports Phys Ther 2016;46(8):689-696. Epub 12 May 2016. doi:10.2519/jospt.2016.6363.

  20. Reliability and Validity of the Turkish Version of the Voice-Related Quality of Life Measure.

    Science.gov (United States)

    Tezcaner, Zahide Çiler; Aksoy, Songül

    2017-03-01

    This study aims to test the validity and reliability of the Turkish version of the Voice-Related Quality of Life (V-RQOL) questionnaire. This is a nonrandomized, prospective study with control group. The questionnaire was administered to 249 individuals-130 with vocal complaint and 119 without-with a mean age of 37.8 ± 12.3 years. The Turkish version of the Voice Handicap Index (VHI) and perceptual voice evaluation measures were also administered at 2-14 days for retest reliability. The instrument was submitted to validity and reliability evaluation. The V-RQOL measure showed a strong internal consistency and test-retest reliability; the Cronbach's alpha coefficient for the overall V-RQOL was 0.969, the physical functioning domain was 0.949, and the social-emotional domain was 0.940. In the test-retest reliability test, the overall V-RQOL was found to be 0.989. The construct validity of the V-RQOL was determined based on the strength and direction of its relation to the VHI and the perceptual voice evaluation measure. The higher the VHI level, the lower the physical functioning, social-emotional, and overall score levels of the V-RQOL (r = -0.927, r = -0.912, r = -0.944, respectively; P reliability and validity and may play a crucial role in evaluating Turkish-speaking patients with voice disorders. Copyright © 2017 The Voice Foundation. Published by Elsevier Inc. All rights reserved.

  1. Experimental techniques and measurement accuracies

    International Nuclear Information System (INIS)

    Bennett, E.F.; Yule, T.J.; DiIorio, G.; Nakamura, T.; Maekawa, H.

    1985-02-01

    A brief description of the experimental tools available for fusion neutronics experiments is given. Attention is paid to error estimates mainly for the measurement of tritium breeding ratio in simulated blankets using various techniques

  2. Reliability of BOD POD Measurements Remains High After a Short-Duration Low-Carbohydrate Diet.

    Science.gov (United States)

    Greer, Beau Kjerulf; Edsall, Kathleen M; Greer, Anna E

    2016-04-01

    The purpose of the current study was to determine whether expected changes in body weight via a 3-day low-carbohydrate (LC) diet will disrupt the reliability of air displacement plethysmography measurements via BOD POD. Twenty-four subjects recorded their typical diets for 3 days before BOD POD and 7-site skinfold analyses. Subjects were matched for lean body mass and divided into low-CHO (LC) and control (CON) groups. The LC group was given instruction intended to prevent more than 50 grams/day of carbohydrate consumption for 3 consecutive days, and the CON group replicated their previously recorded diet. Body composition measurements were repeated after dietary intervention. Test-retest reliability measures were significant (p fat percentage in both the LC and the CON groups (rs = .993 and .965, respectively). Likewise, skinfold analysis for body fat percentage reliability was high in both groups (rs = .996 and .997, respectively). There were significant differences between 1st and 2nd BOD POD measurements for body mass (72.9 ± 13.3 vs. 72.1 ± 13.0 kg [M ± SD]) and body volume (69.0 ± 12.7-68.1 ± 12.2 L) in the LC group (p .05) in BOD POD-determined body fat percentage, lean body mass, or fat mass between the 1st and 2nd trial in either group. Body composition measures via BOD POD and 7-site skinfolds remain reliable after 3 days of an LC diet despite significant decreases in body mass.

  3. Improving machinery reliability

    CERN Document Server

    Bloch, Heinz P

    1998-01-01

    This totally revised, updated and expanded edition provides proven techniques and procedures that extend machinery life, reduce maintenance costs, and achieve optimum machinery reliability. This essential text clearly describes the reliability improvement and failure avoidance steps practiced by best-of-class process plants in the U.S. and Europe.

  4. Reliability and validity of the Pragmatics Observational Measure (POM): a new observational measure of pragmatic language for children.

    Science.gov (United States)

    Cordier, Reinie; Munro, Natalie; Wilkes-Gillan, Sarah; Speyer, Renée; Pearce, Wendy M

    2014-07-01

    There is a need for a reliable and valid assessment of childhood pragmatic language skills during peer-peer interactions. This study aimed to evaluate the psychometric properties of a newly developed pragmatic assessment, the Pragmatic Observational Measure (POM). The psychometric properties of the POM were investigated from observational data of two studies - study 1 involved 342 children aged 5-11 years (108 children with ADHD; 108 typically developing playmates; 126 children in the control group), and study 2 involved 9 children with ADHD who attended a 7-week play-based intervention. The psychometric properties of the POM were determined based on the COnsensus-based Standards for the selection of health status Measurement INstruments (COSMIN) taxonomy of psychometric properties and definitions for health-related outcomes; the Pragmatic Protocol was used as the reference tool against which the POM was evaluated. The POM demonstrated sound psychometric properties in all the reliability, validity and interpretability criteria against which it was assessed. The findings showed that the POM is a reliable and valid measure of pragmatic language skills of children with ADHD between the age of 5 and 11 years and has clinical utility in identifying children with pragmatic language difficulty. Copyright © 2014 The Authors. Published by Elsevier Ltd.. All rights reserved.

  5. 14CO2 labeling. A reliable technique for rapid measurement of total root exudation capacity and vascular sap flow in crop plants

    International Nuclear Information System (INIS)

    Bhupinder Singh; Sumedha Ahuja; Renu Pandey; Singhal, R.K.

    2014-01-01

    Root release of organic compounds and rate of the vascular sap flow are important for understanding the nutrient and the source-sink dynamics in plants, however, their determination is procedurally cumbersome and time consuming. We report here a simple method involving 14 C labeling for rapid and reliable measurement of root exudates and vascular sap flow rate in a variable groundnut population developed through seed gamma irradiation using a cobalt source ( 60 Co). An experimental hypothesis that a higher 14 C level in the vascular sap would indicate a higher root release of carbon by the roots into the rhizosphere was verified. (author)

  6. Program integration of predictive maintenance with reliability centered maintenance

    International Nuclear Information System (INIS)

    Strong, D.K. Jr; Wray, D.M.

    1990-01-01

    This paper addresses improving the safety and reliability of power plants in a cost-effective manner by integrating the recently developed reliability centered maintenance techniques with the traditional predictive maintenance techniques of nuclear power plants. The topics of the paper include a description of reliability centered maintenance (RCM), enhancing RCM with predictive maintenance, predictive maintenance programs, condition monitoring techniques, performance test techniques, the mid-Atlantic Reliability Centered Maintenance Users Group, test guides and the benefits of shared guide development

  7. Reliability of lower limb alignment measures using an established landmark-based method with a customized computer software program

    Science.gov (United States)

    Sled, Elizabeth A.; Sheehy, Lisa M.; Felson, David T.; Costigan, Patrick A.; Lam, Miu; Cooke, T. Derek V.

    2010-01-01

    The objective of the study was to evaluate the reliability of frontal plane lower limb alignment measures using a landmark-based method by (1) comparing inter- and intra-reader reliability between measurements of alignment obtained manually with those using a computer program, and (2) determining inter- and intra-reader reliability of computer-assisted alignment measures from full-limb radiographs. An established method for measuring alignment was used, involving selection of 10 femoral and tibial bone landmarks. 1) To compare manual and computer methods, we used digital images and matching paper copies of five alignment patterns simulating healthy and malaligned limbs drawn using AutoCAD. Seven readers were trained in each system. Paper copies were measured manually and repeat measurements were performed daily for 3 days, followed by a similar routine with the digital images using the computer. 2) To examine the reliability of computer-assisted measures from full-limb radiographs, 100 images (200 limbs) were selected as a random sample from 1,500 full-limb digital radiographs which were part of the Multicenter Osteoarthritis (MOST) Study. Three trained readers used the software program to measure alignment twice from the batch of 100 images, with two or more weeks between batch handling. Manual and computer measures of alignment showed excellent agreement (intraclass correlations [ICCs] 0.977 – 0.999 for computer analysis; 0.820 – 0.995 for manual measures). The computer program applied to full-limb radiographs produced alignment measurements with high inter- and intra-reader reliability (ICCs 0.839 – 0.998). In conclusion, alignment measures using a bone landmark-based approach and a computer program were highly reliable between multiple readers. PMID:19882339

  8. Reliability of a single objective measure in assessing sleepiness.

    Science.gov (United States)

    Sunwoo, Bernie Y; Jackson, Nicholas; Maislin, Greg; Gurubhagavatula, Indira; George, Charles F; Pack, Allan I

    2012-01-01

    To evaluate reliability of single objective tests in assessing sleepiness. Subjects who completed polysomnography underwent a 4-nap multiple sleep latency test (MSLT) the following day. Prior to each nap opportunity on MSLT, subjects performed the psychomotor vigilance test (PVT) and divided attention driving task (DADT). Results of single versus multiple test administrations were compared using the intraclass correlation coefficient (ICC) and adjusted for test administration order effects to explore time of day effects. Measures were explored as continuous and binary (i.e., impaired or not impaired). Community-based sample evaluated at a tertiary, university-based sleep center. 372 adult commercial vehicle operators oversampled for increased obstructive sleep apnea risk. N/A. AS CONTINUOUS MEASURES, ICC WERE AS FOLLOWS: MSLT 0.45, PVT median response time 0.69, PVT number of lapses 0.51, 10-min DADT tracking error 0.87, 20-min DADT tracking error 0.90. Based on binary outcomes, ICC were: MSLT 0.63, PVT number of lapses 0.85, 10-min DADT 0.95, 20-min DADT 0.96. Statistically significant time of day effects were seen in both the MSLT and PVT but not the DADT. Correlation between ESS and different objective tests was strongest for MSLT, range [-0.270 to -0.195] and persisted across all time points. Single DADT and PVT administrations are reliable measures of sleepiness. A single MSLT administration can reasonably discriminate individuals with MSL < 8 minutes. These results support the use of a single administration of some objective tests of sleepiness when performed under controlled conditions in routine clinical care.

  9. Inter-rater reliability of kinesthetic measurements with the KINARM robotic exoskeleton.

    Science.gov (United States)

    Semrau, Jennifer A; Herter, Troy M; Scott, Stephen H; Dukelow, Sean P

    2017-05-22

    Kinesthesia (sense of limb movement) has been extremely difficult to measure objectively, especially in individuals who have survived a stroke. The development of valid and reliable measurements for proprioception is important to developing a better understanding of proprioceptive impairments after stroke and their impact on the ability to perform daily activities. We recently developed a robotic task to evaluate kinesthetic deficits after stroke and found that the majority (~60%) of stroke survivors exhibit significant deficits in kinesthesia within the first 10 days post-stroke. Here we aim to determine the inter-rater reliability of this robotic kinesthetic matching task. Twenty-five neurologically intact control subjects and 15 individuals with first-time stroke were evaluated on a robotic kinesthetic matching task (KIN). Subjects sat in a robotic exoskeleton with their arms supported against gravity. In the KIN task, the robot moved the subjects' stroke-affected arm at a preset speed, direction and distance. As soon as subjects felt the robot begin to move their affected arm, they matched the robot movement with the unaffected arm. Subjects were tested in two sessions on the KIN task: initial session and then a second session (within an average of 18.2 ± 13.8 h of the initial session for stroke subjects), which were supervised by different technicians. The task was performed both with and without the use of vision in both sessions. We evaluated intra-class correlations of spatial and temporal parameters derived from the KIN task to determine the reliability of the robotic task. We evaluated 8 spatial and temporal parameters that quantify kinesthetic behavior. We found that the parameters exhibited moderate to high intra-class correlations between the initial and retest conditions (Range, r-value = [0.53-0.97]). The robotic KIN task exhibited good inter-rater reliability. This validates the KIN task as a reliable, objective method for quantifying

  10. Fluid temperature measurement technique by using Raman scattering

    International Nuclear Information System (INIS)

    An, Jeong Soo; Yang, Sun Kyu; Min, Kyung Ho; Chung, Moon Ki; Choi, Young Don

    1999-06-01

    Temperature measurement technique by using Raman scattering was developed for the liquid water at temperature of 20 - 90 degree C and atmospheric pressure. Strong relationship between Raman scattering characteristics and liquid temperature change was observed. Various kinds of measurement techniques, such as Peak Intensity, Peak Wavelength, FWHM (Full Width at Half Maximum), PMCR ( Polymer Monomer Concentration RAte), TSIR (Temperature Sensitive Intensity Ratio), IDIA (Integral Difference Intensity Area) were tested. TSIR has the highest accuracy in mean error or 0.1 deg C and standard deviation of 0.1248 deg C. This report is one of the results in developing process of Raman temperature measurement technique. Next research step is to develop Raman temperature measurement technique at the high temperature and high pressure conditions in single or two phase flows. (author). 13 refs., 3 tabs., 38 figs

  11. Computational area measurement of orbital floor fractures: Reliability, accuracy and rapidity

    International Nuclear Information System (INIS)

    Schouman, Thomas; Courvoisier, Delphine S.; Imholz, Benoit; Van Issum, Christopher; Scolozzi, Paolo

    2012-01-01

    Objective: To evaluate the reliability, accuracy and rapidity of a specific computational method for assessing the orbital floor fracture area on a CT scan. Method: A computer assessment of the area of the fracture, as well as that of the total orbital floor, was determined on CT scans taken from ten patients. The ratio of the fracture's area to the orbital floor area was also calculated. The test–retest precision of measurement calculations was estimated using the Intraclass Correlation Coefficient (ICC) and Dahlberg's formula to assess the agreement across observers and across measures. The time needed for the complete assessment was also evaluated. Results: The Intraclass Correlation Coefficient across observers was 0.92 [0.85;0.96], and the precision of the measures across observers was 4.9%, according to Dahlberg's formula .The mean time needed to make one measurement was 2 min and 39 s (range, 1 min and 32 s to 4 min and 37 s). Conclusion: This study demonstrated that (1) the area of the orbital floor fracture can be rapidly and reliably assessed by using a specific computer system directly on CT scan images; (2) this method has the potential of being routinely used to standardize the post-traumatic evaluation of orbital fractures

  12. Reliability of measuring pelvic floor elevation with a diagnostic ultrasonic imaging device

    OpenAIRE

    Ubukata, Hitomi; Maruyama, Hitoshi; Huo, Ming

    2015-01-01

    [Purpose] The purpose of this study was to investigate the reliability of measuring the amount of pelvic floor elevation during pelvic and abdominal muscle contraction with a diagnostic ultrasonic imaging device. [Subjects] The study group comprised 11 healthy women without urinary incontinence or previous birth experience. [Methods] We measured the displacement elevation of the bladder base during contraction of the abdominal and pelvic floor muscles was measured using a diagnostic ultrasoni...

  13. ImageJ: A Free, Easy, and Reliable Method to Measure Leg Ulcers Using Digital Pictures.

    Science.gov (United States)

    Aragón-Sánchez, Javier; Quintana-Marrero, Yurena; Aragón-Hernández, Cristina; Hernández-Herero, María José

    2017-12-01

    Wound measurement to document the healing course of chronic leg ulcers has an important role in the management of these patients. Digital cameras in smartphones are readily available and easy to use, and taking pictures of wounds is becoming a routine in specialized departments. Analyzing digital pictures with appropriate software provides clinicians a quick, clean, and easy-to-use tool for measuring wound area. A set of 25 digital pictures of plain foot and leg ulcers was the basis of this study. Photographs were taken placing a ruler next to the wound in parallel with the healthy skin with the iPhone 6S (Apple Inc, Cupertino, CA), which has a camera of 12 megapixels using the flash. The digital photographs were visualized with ImageJ 1.45s freeware (National Institutes of Health, Rockville, MD; http://imagej.net/ImageJ ). Wound area measurement was carried out by 4 raters: head of the department, wound care nurse, physician, and medical student. We assessed intra- and interrater reliability using the interclass correlation coefficient. To determine intraobserver reliability, 2 of the raters repeated the measurement of the set 1 week after the first reading. The interrater model displayed an interclass correlation coefficient of 0.99 with 95% confidence interval of 0.999 to 1.000, showing excellent reliability. The intrarater model of both examiners showed excellent reliability. In conclusion, analyzing digital images of leg ulcers with ImageJ estimates wound area with excellent reliability. This method provides a free, rapid, and accurate way to measure wounds and could routinely be used to document wound healing in daily clinical practice.

  14. Characteristics of Laser Flash Technique for Thermal Diffusivity Measurement

    Energy Technology Data Exchange (ETDEWEB)

    Park, D. G.; Kim, H. M.; Hong, G. P

    2008-08-15

    In relation to selection of thermal conductivity measurement technology, various thermal conductivity measurement technique are investigated for characteristics of each technique and it's measurable range. For the related laser flash techniques, various technical characteristics are reviewed and discussed. Especially, Parker adiabatic model are reviewed because of importance for basic theory of the thermal diffusivity determination. Finite pulse time effect, heat loss effect and non-uniform heating effect, which are main technical factors for laser flash technique, are considered. Finally, characteristics of constituent elements for laser flash measurement system are reviewed and investigated in detail.

  15. Reliability measures for indexed semi-Markov chains applied to wind energy production

    International Nuclear Information System (INIS)

    D'Amico, Guglielmo; Petroni, Filippo; Prattico, Flavio

    2015-01-01

    The computation of the dependability measures is a crucial point in many engineering problems as well as in the planning and development of a wind farm. In this paper we address the issue of energy production by wind turbines by using an indexed semi-Markov chain as a model of wind speed. We present the mathematical model, the data and technical characteristics of a commercial wind turbine (Aircon HAWT-10kW). We show how to compute some of the main dependability measures such as reliability, availability and maintainability functions. We compare the results of the model with real energy production obtained from data available in the Lastem station (Italy) and sampled every 10 min. - Highlights: • Semi-Markov models. • Time series generation of wind speed. • Computation of availability, reliability and maintainability.

  16. Cyber Physical Systems for User Reliability Measurements in a Sharing Economy Environment.

    Science.gov (United States)

    Seo, Aria; Jeong, Junho; Kim, Yeichang

    2017-08-13

    As the sharing economic market grows, the number of users is also increasing but many problems arise in terms of reliability between providers and users in the processing of services. The existing methods provide shared economic systems that judge the reliability of the provider from the viewpoint of the user. In this paper, we have developed a system for establishing mutual trust between providers and users in a shared economic environment to solve existing problems. In order to implement a system that can measure and control users' situation in a shared economic environment, we analyzed the necessary factors in a cyber physical system (CPS). In addition, a user measurement system based on a CPS structure in a sharing economic environment is implemented through analysis of the factors to consider when constructing a CPS.

  17. Evaluating test-retest reliability in patient-reported outcome measures for older people: A systematic review.

    Science.gov (United States)

    Park, Myung Sook; Kang, Kyung Ja; Jang, Sun Joo; Lee, Joo Yun; Chang, Sun Ju

    2018-03-01

    This study aimed to evaluate the components of test-retest reliability including time interval, sample size, and statistical methods used in patient-reported outcome measures in older people and to provide suggestions on the methodology for calculating test-retest reliability for patient-reported outcomes in older people. This was a systematic literature review. MEDLINE, Embase, CINAHL, and PsycINFO were searched from January 1, 2000 to August 10, 2017 by an information specialist. This systematic review was guided by both the Preferred Reporting Items for Systematic Reviews and Meta-Analyses checklist and the guideline for systematic review published by the National Evidence-based Healthcare Collaborating Agency in Korea. The methodological quality was assessed by the Consensus-based Standards for the selection of health Measurement Instruments checklist box B. Ninety-five out of 12,641 studies were selected for the analysis. The median time interval for test-retest reliability was 14days, and the ratio of sample size for test-retest reliability to the number of items in each measure ranged from 1:1 to 1:4. The most frequently used statistical methods for continuous scores was intraclass correlation coefficients (ICCs). Among the 63 studies that used ICCs, 21 studies presented models for ICC calculations and 30 studies reported 95% confidence intervals of the ICCs. Additional analyses using 17 studies that reported a strong ICC (>0.09) showed that the mean time interval was 12.88days and the mean ratio of the number of items to sample size was 1:5.37. When researchers plan to assess the test-retest reliability of patient-reported outcome measures for older people, they need to consider an adequate time interval of approximately 13days and the sample size of about 5 times the number of items. Particularly, statistical methods should not only be selected based on the types of scores of the patient-reported outcome measures, but should also be described clearly in

  18. Reliability analysis in intelligent machines

    Science.gov (United States)

    Mcinroy, John E.; Saridis, George N.

    1990-01-01

    Given an explicit task to be executed, an intelligent machine must be able to find the probability of success, or reliability, of alternative control and sensing strategies. By using concepts for information theory and reliability theory, new techniques for finding the reliability corresponding to alternative subsets of control and sensing strategies are proposed such that a desired set of specifications can be satisfied. The analysis is straightforward, provided that a set of Gaussian random state variables is available. An example problem illustrates the technique, and general reliability results are presented for visual servoing with a computed torque-control algorithm. Moreover, the example illustrates the principle of increasing precision with decreasing intelligence at the execution level of an intelligent machine.

  19. Reliability and Validity of Computerized Force Platform Measures of Balance Function in Healthy Older Adults.

    Science.gov (United States)

    Harro, Cathy C; Garascia, Chelsea

    2018-01-10

    Postural control declines with aging and is an independent risk factor for falls in older adults. Objective examination of balance function is warranted to direct fall prevention strategies. Force platform (FP) systems provide quantitative measures of postural control and analysis of different aspects of balance. The purpose of this study was to examine the reliability and validity of FP measures in healthy older adults. This study enrolled 46 healthy elderly adults, mean age 67.67 (5.1) years, who had no history of falls. They were assessed on 3 standardized tests on the NeuroCom Equitest FP system: limits of stability (LOS), motor control test (MCT), and sensory organization test (SOT). The test battery was administered twice within a 10-day period for test-retest reliability; intraclass correlation coefficients (ICCs), standard error of measurement (SEM), and minimal detectable change based on a 95% confidence interval (MDC95) were calculated. FP measures were compared with criterion clinical balance (Mini-BESTest and Functional Gait Assessment) and gait (10-m walk and 6-minute walk) measures to examine concurrent validity using Pearson correlation coefficients. Multiple linear regression analysis examined whether age and activity level were associated with FP performance. The α level was set at P point excursion measures all demonstrated excellent test-retest reliability (ICC = 0.90, 0.85, and 0.77, respectively), whereas moderate to good reliability was found for SOT vestibular ratio score (ICC = 0.71). There was large variability in performance in this healthy elderly cohort, resulting in relatively large MDC95 for these measures, especially for the LOS test. Fair correlations were found between LOS end point excursion and clinical balance and gait measures (r = 0.31-0.49), and between MCT average latency and gait measures only (r = -0.32). No correlations were found between SOT measures and clinical balance and gait measures. Age was only marginally

  20. Reliability of diagnostic imaging techniques in suspected acute appendicitis: proposed diagnostic protocol

    International Nuclear Information System (INIS)

    Cura del, J. L.; Oleaga, L.; Grande, D.; Vela, A. C.; Ibanez, A. M.

    2001-01-01

    To study the utility of ultrasound and computed tomography (CT) in case of suspected appendicitis. To determine the diagnostic yield in terms of different clinical contexts and patient characteristics. to assess the costs and benefits of introducing these techniques and propose a protocol for their use. Negative appendectomies, complications and length of hospital stay in a group of 152 patients with suspected appendicitis who underwent ultrasound and CT were compared with those of 180 patients who underwent appendectomy during the same time period, but had not been selected for the first group: these patients costs for each group were calculated. In the first group, the diagnostic value of the clinical signs was also evaluated. The reliability of the clinical signs was limited, while the results with ultrasound and CT were excellent. The incidence of negative appendectomy was 9.6% in the study group and 12.2% in the control group. Moreover, there were fewer complications and a shorter hospital stay in the first group. Among men, however, the rate of negative appendectomy was lower in the control group. The cost of using ultrasound and CT in the management of appendicitis was only slightly higher than that of the control group. Although ultrasound and CT are not necessary in cases in which the probability of appendicitis is low or in men presenting clear clinical evidence, the use of these techniques is indicated in the remaining cases in which appendicitis is suspected. In children, ultrasound is the technique of choice. In all other patients, if negative results are obtained with one of the two techniques, the other should be performed. (Author) 49 refs

  1. Study on highly reliable digital communication technology of reactor nuclear measuring equipment

    International Nuclear Information System (INIS)

    Gu Pengfei; Huang Xiaojin

    2007-01-01

    To meet the need of highly reliable of reactor nuclear measuring equipment, in allusion to the idiographic request of nuclear measuring equipment, the actual technical development and the application in industrial field, we design a kind of redundancy communication net based on PROFIBUS, and a kind of communication interface module based on redundancy PROFIBUS communication, which link the nuclear measuring equipment and PROFIBUS communication net, and also lay a foundation for advanced research. (authors)

  2. Knowledge-base for the new human reliability analysis method, A Technique for Human Error Analysis (ATHEANA)

    International Nuclear Information System (INIS)

    Cooper, S.E.; Wreathall, J.; Thompson, C.M., Drouin, M.; Bley, D.C.

    1996-01-01

    This paper describes the knowledge base for the application of the new human reliability analysis (HRA) method, a ''A Technique for Human Error Analysis'' (ATHEANA). Since application of ATHEANA requires the identification of previously unmodeled human failure events, especially errors of commission, and associated error-forcing contexts (i.e., combinations of plant conditions and performance shaping factors), this knowledge base is an essential aid for the HRA analyst

  3. Reliability and reference values of two clinical measurements of dynamic and static knee position in healthy children

    DEFF Research Database (Denmark)

    Ortqvist, Maria; Moström, Eva B; Roos, Ewa M.

    2011-01-01

    PURPOSE: The purposes of this study were to evaluate reliability of the Single-limb mini squat test (a dynamic measure of medio-lateral knee position) and the Quadriceps-angle (Q-angle) (a static measure of medio-lateral knee position), present paediatric reference values of the Q......-angle measurements was found. Reference values for the Q-angle (mean 13.5° (1.9)-15.3° (2.8)) varies with age and gender. No associations were found between dynamic and static measures. CONCLUSIONS: The Single-limb mini squat test showed a moderate reliability and the Q-angle showed a fair to moderate reliability......-angle, and evaluate the association between the tests. METHODS: Two hundred and forty-six healthy children (9-16 years) were included (intra/inter-rater reliability for Q-angle (n = 37/85) and for Single-limb mini squat test (n = 33/28)). Dynamic medio-lateral knee position was assessed by the Single-limb mini squat...

  4. Measurement of void fractions by nuclear techniques

    International Nuclear Information System (INIS)

    Hernandez G, A.; Vazquez G, J.; Diaz H, C.; Salinas R, G.A.

    1997-01-01

    In this work it is done a general analysis of those techniques used to determine void fractions and it is chosen a nuclear technique to be used in the heat transfer circuit of the Physics Department of the Basic Sciences Management. The used methods for the determination of void fractions are: radioactive absorption, acoustic techniques, average velocity measurement, electromagnetic flow measurement, optical methods, oscillating absorption, nuclear magnetic resonance, relation between pressure and flow oscillation, infrared absorption methods, sound neutron analysis. For the case of this work it will be treated about the radioactive absorption method which is based in the gamma rays absorption. (Author)

  5. Reliability measures of a computer system with priority to PM over the H/W repair activities subject to MOT and MRT

    Directory of Open Access Journals (Sweden)

    Ashish Kumar

    2015-01-01

    Full Text Available This paper concentrates on the evaluation of reliability measures of a computer system of two-identical units having independent failure of h/w and s/w components. Initially one unit is operative and the other is kept as spare in cold standby. There is a single server visiting the system immediately whenever needed. The server conducts preventive maintenance of the unit after a maximum operation time. If server is unable to repair the h/w components in maximum repair time, then components in the unit are replaced immediately by new one. However, only replacement of the s/w components has been made at their failure. The priority is given to the preventive maintenance over repair activities of the h/w. The time to failure of the components follows negative exponential distribution whereas the distribution of preventive maintenance, repair and replacement time are taken as arbitrary. The expressions for some important reliability measures of system effectiveness have been derived using semi-Markov process and regenerative point technique. The graphical behavior of the results has also been shown for a particular case.

  6. Reliability of widefield capillary microscopy to measure nailfold capillary density in systemic sclerosis.

    Science.gov (United States)

    Hudson, M; Masetto, A; Steele, R; Arthurs, E; Baron, M

    2010-01-01

    To determine intra- and inter-observer reliability of widefield microscopy to measure nailfold capillary density in patients with systemic sclerosis (SSc). Five SSc patients were examined with a STEMV-8 Zeiss biomicroscope with 50x magnification. The nailfold of the second, third, fourth and fifth fingers of both hands of each patient were photographed twice by each of two observers, once in the morning and again in the afternoon (total of 32 pictures). Two raters reviewed the photographs to produce capillary density readings. Intra- and inter-rater reliability of the readings were computed using intra-class correlations (ICC). Additional analyses were undertaken to determine the impact of other sources of variability in the data, namely patient, finger, technician and time. Intra-and inter-rater reliability were substantial (ICC 0.72-0.84) when raters were reading the same photographs or photographs taken at the same time of day. Agreement was only fair between morning and afternoon density readings (ICC 0.30-0.37). Patients, individual fingers and technician accounted for a large part of the variability in the data (combined variance component of 7.69 out of the total 12.23). The coefficient of variation of widefield microscopy was 24%. Although intra- and inter-rater reliability of nailfold capillary density measurements using widefield microscopy are good, proper standardisation of the conditions under which capillaroscopy is done and better imaging of nailfold capillary abnormalities should be considered if nailfold capillary density is to be used as an outcome measure in multi-centre clinical trials in SSc.

  7. A Systematic Review of Statistical Methods Used to Test for Reliability of Medical Instruments Measuring Continuous Variables

    Directory of Open Access Journals (Sweden)

    Rafdzah Zaki

    2013-06-01

    Full Text Available   Objective(s: Reliability measures precision or the extent to which test results can be replicated. This is the first ever systematic review to identify statistical methods used to measure reliability of equipment measuring continuous variables. This studyalso aims to highlight the inappropriate statistical method used in the reliability analysis and its implication in the medical practice.   Materials and Methods: In 2010, five electronic databases were searched between 2007 and 2009 to look for reliability studies. A total of 5,795 titles were initially identified. Only 282 titles were potentially related, and finally 42 fitted the inclusion criteria. Results: The Intra-class Correlation Coefficient (ICC is the most popular method with 25 (60% studies having used this method followed by the comparing means (8 or 19%. Out of 25 studies using the ICC, only 7 (28% reported the confidence intervals and types of ICC used. Most studies (71% also tested the agreement of instruments. Conclusion: This study finds that the Intra-class Correlation Coefficient is the most popular method used to assess the reliability of medical instruments measuring continuous outcomes. There are also inappropriate applications and interpretations of statistical methods in some studies. It is important for medical researchers to be aware of this issue, and be able to correctly perform analysis in reliability studies.

  8. Determining Reliability and Validity of the Persian Version of Software Usability Measurements Inventory (SUMI) Questionnaire

    OpenAIRE

    seyed abolfazl zakerian; Roya Azizi; Mehdi Rahgozar

    2013-01-01

    The term usability refers to a special index for success of an operating system. This study aimed to determine the reliability and validity of the Software Usability Measurements Inventory (SUMI) questionnaire as one of the valid and common questionnaires about usability evaluation. The back translation method was used to translate the questionnaire from English to Persian back to English. Moreover, repeatability or test-retest reliability was practically used to determine the reliability of ...

  9. An improved technique for quasi-static C-V measurements

    International Nuclear Information System (INIS)

    Turan, R.; Finstad, T.G.

    1990-10-01

    A new automated quasi-static C-V measurement technique for MOS capacitors has been developed. This techniques uses an integrating electrometer to measure the charge accumulated on a MOS capacitor in response of a small voltage step. Making use of the internal data storage system of a commercial electrometer and a personal computer, the charge Q on the MOS capacitor is measured as a function of time t and stored. The capacitance is then obtained by analyzing this Q-t data set. A Si MOS sample is measured and analyzed in terms of interface charges as an example. Advantages over a commercial quasi-static meter which uses similar measurement technique are presented. It is also shown that this technique is potentially capable of measuring both high and low frequency C-V curves simultaneously. 9 refs. 5 figs

  10. Center edge angle measurement for hip preservation surgery: technique and caveats.

    Science.gov (United States)

    Anderson, Lucas A; Gililland, Jeremy; Pelt, Christopher; Linford, Samuel; Stoddard, Gregory J; Peters, Christopher L

    2011-01-01

    Anterior and lateral center edge angles have traditionally been used to determine acetabular coverage, and thereby strongly influence the decision to perform acetabular reorientation versus osteochondroplasty in patients with dysplasia and/or femoroacetabular impingement. We propose templating the center of the contained articular femoral head in aspherical hips to provide reliable assessment of acetabular coverage. Digital radiographs of 30 patients with various combinations of femoral and acetabular morphologies were evaluated using 2 methods to identify the anterior center edge angle and lateral center edge angle. The control method used an estimated femoral head center for angle apex. The study technique determined the center of the femoral head by templating the congruent aspect of the femoral head contained by the acetabulum while ignoring the increasing lateral and anterior radius associated with cam deformities. Four readers measured lateral center edge angles on anteroposterior radiographs and anterior center edge angles on false-profile radiographs. Two reads were performed by each reader using both the estimated and the templated methods for a total of 4 reads. Interobserver reliability using the proposed method compared to the standard was much improved for anterior center edge angles (intraclass correlation coefficient of 0.76 vs 0.55) as well as with lateral center edge angles (ICC of 0.80 vs 0.42). Decreased correlation was most commonly associated with abnormal sourcil morphology, posterior wall deficiency combined with calcified labra, and os acetabuli. Including the anterolateral cam deformity in identifying the center of the femoral head for measuring center edge angles leads to an underestimation of acetabular coverage, which may negatively affect hip preservation surgical decision making. Copyright 2011, SLACK Incorporated.

  11. Photovoltaic power system reliability considerations

    Science.gov (United States)

    Lalli, V. R.

    1980-01-01

    This paper describes an example of how modern engineering and safety techniques can be used to assure the reliable and safe operation of photovoltaic power systems. This particular application was for a solar cell power system demonstration project in Tangaye, Upper Volta, Africa. The techniques involve a definition of the power system natural and operating environment, use of design criteria and analysis techniques, an awareness of potential problems via the inherent reliability and FMEA methods, and use of a fail-safe and planned spare parts engineering philosophy.

  12. Cavity ring-down technique for measurement of reflectivity of high ...

    Indian Academy of Sciences (India)

    Laser & Plasma Technology Division, Bhabha Atomic Research Centre, Mumbai 400 085,. India. *Corresponding author. E-mail: gsridhar@barc.gov.in. Abstract. A simple, accurate and reliable method for measuring the reflectivity of laser- ... Keywords. Cavity ring-down method; reflectivity measurement; optical resonator.

  13. Application-Driven Reliability Measures and Evaluation Tool for Fault-Tolerant Real-Time Systems

    National Research Council Canada - National Science Library

    Krishna, C

    2001-01-01

    .... The measure combines graphic-theoretic concepts in evaluating the underlying reliability of the network and other means to evaluate the ability of the network to support interprocessor traffic...

  14. Reliable design of electronic equipment an engineering guide

    CERN Document Server

    Natarajan, Dhanasekharan

    2014-01-01

    This book explains reliability techniques with examples from electronics design for the benefit of engineers. It presents the application of de-rating, FMEA, overstress analyses and reliability improvement tests for designing reliable electronic equipment. Adequate information is provided for designing computerized reliability database system to support the application of the techniques by designers. Pedantic terms and the associated mathematics of reliability engineering discipline are excluded for the benefit of comprehensiveness and practical applications. This book offers excellent support

  15. Reliability-Based Shape Optimization using Stochastic Finite Element Methods

    DEFF Research Database (Denmark)

    Enevoldsen, Ib; Sørensen, John Dalsgaard; Sigurdsson, G.

    1991-01-01

    stochastic fields (e.g. loads and material parameters such as Young's modulus and the Poisson ratio). In this case stochastic finite element techniques combined with FORM analysis can be used to obtain measures of the reliability of the structural systems, see Der Kiureghian & Ke (6) and Liu & Der Kiureghian...

  16. Measurement methods to assess diastasis of the rectus abdominis muscle (DRAM): A systematic review of their measurement properties and meta-analytic reliability generalisation.

    Science.gov (United States)

    van de Water, A T M; Benjamin, D R

    2016-02-01

    Systematic literature review. Diastasis of the rectus abdominis muscle (DRAM) has been linked with low back pain, abdominal and pelvic dysfunction. Measurement is used to either screen or to monitor DRAM width. Determining which methods are suitable for screening and monitoring DRAM is of clinical value. To identify the best methods to screen for DRAM presence and monitor DRAM width. AMED, Embase, Medline, PubMed and CINAHL databases were searched for measurement property studies of DRAM measurement methods. Population characteristics, measurement methods/procedures and measurement information were extracted from included studies. Quality of all studies was evaluated using 'quality rating criteria'. When possible, reliability generalisation was conducted to provide combined reliability estimations. Thirteen studies evaluated measurement properties of the 'finger width'-method, tape measure, calipers, ultrasound, CT and MRI. Ultrasound was most evaluated. Methodological quality of these studies varied widely. Pearson's correlations of r = 0.66-0.79 were found between calipers and ultrasound measurements. Calipers and ultrasound had Intraclass Correlation Coefficients (ICC) of 0.78-0.97 for test-retest, inter- and intra-rater reliability. The 'finger width'-method had weighted Kappa's of 0.73-0.77 for test-retest reliability, but moderate agreement (63%; weighted Kappa = 0.53) between raters. Comparing calipers and ultrasound, low measurement error was found (above the umbilicus), and the methods had good agreement (83%; weighted Kappa = 0.66) for discriminative purposes. The available information support ultrasound and calipers as adequate methods to assess DRAM. For other methods limited measurement information of low to moderate quality is available and further evaluation of their measurement properties is required. Copyright © 2015 Elsevier Ltd. All rights reserved.

  17. Regional inversion of CO2 ecosystem fluxes from atmospheric measurements. Reliability of the uncertainty estimates

    Energy Technology Data Exchange (ETDEWEB)

    Broquet, G.; Chevallier, F.; Breon, F.M.; Yver, C.; Ciais, P.; Ramonet, M.; Schmidt, M. [Laboratoire des Sciences du Climat et de l' Environnement, CEA-CNRS-UVSQ, UMR8212, IPSL, Gif-sur-Yvette (France); Alemanno, M. [Servizio Meteorologico dell' Aeronautica Militare Italiana, Centro Aeronautica Militare di Montagna, Monte Cimone/Sestola (Italy); Apadula, F. [Research on Energy Systems, RSE, Environment and Sustainable Development Department, Milano (Italy); Hammer, S. [Universitaet Heidelberg, Institut fuer Umweltphysik, Heidelberg (Germany); Haszpra, L. [Hungarian Meteorological Service, Budapest (Hungary); Meinhardt, F. [Federal Environmental Agency, Kirchzarten (Germany); Necki, J. [AGH University of Science and Technology, Krakow (Poland); Piacentino, S. [ENEA, Laboratory for Earth Observations and Analyses, Palermo (Italy); Thompson, R.L. [Max Planck Institute for Biogeochemistry, Jena (Germany); Vermeulen, A.T. [Energy research Centre of the Netherlands ECN, EEE-EA, Petten (Netherlands)

    2013-07-01

    The Bayesian framework of CO2 flux inversions permits estimates of the retrieved flux uncertainties. Here, the reliability of these theoretical estimates is studied through a comparison against the misfits between the inverted fluxes and independent measurements of the CO2 Net Ecosystem Exchange (NEE) made by the eddy covariance technique at local (few hectares) scale. Regional inversions at 0.5{sup 0} resolution are applied for the western European domain where {approx}50 eddy covariance sites are operated. These inversions are conducted for the period 2002-2007. They use a mesoscale atmospheric transport model, a prior estimate of the NEE from a terrestrial ecosystem model and rely on the variational assimilation of in situ continuous measurements of CO2 atmospheric mole fractions. Averaged over monthly periods and over the whole domain, the misfits are in good agreement with the theoretical uncertainties for prior and inverted NEE, and pass the chi-square test for the variance at the 30% and 5% significance levels respectively, despite the scale mismatch and the independence between the prior (respectively inverted) NEE and the flux measurements. The theoretical uncertainty reduction for the monthly NEE at the measurement sites is 53% while the inversion decreases the standard deviation of the misfits by 38 %. These results build confidence in the NEE estimates at the European/monthly scales and in their theoretical uncertainty from the regional inverse modelling system. However, the uncertainties at the monthly (respectively annual) scale remain larger than the amplitude of the inter-annual variability of monthly (respectively annual) fluxes, so that this study does not engender confidence in the inter-annual variations. The uncertainties at the monthly scale are significantly smaller than the seasonal variations. The seasonal cycle of the inverted fluxes is thus reliable. In particular, the CO2 sink period over the European continent likely ends later than

  18. Reliability and reproducibility analysis of the Cobb angle and assessing sagittal plane by computer-assisted and manual measurement tools.

    Science.gov (United States)

    Wu, Weifei; Liang, Jie; Du, Yuanli; Tan, Xiaoyi; Xiang, Xuanping; Wang, Wanhong; Ru, Neng; Le, Jinbo

    2014-02-06

    Although many studies on reliability and reproducibility of measurement have been performed on coronal Cobb angle, few results about reliability and reproducibility are reported on sagittal alignment measurement including the pelvis. We usually use SurgimapSpine software to measure the Cobb angle in our studies; however, there are no reports till date on its reliability and reproducible measurements. Sixty-eight standard standing posteroanterior whole-spine radiographs were reviewed. Three examiners carried out the measurements independently under the settings of manual measurement on X-ray radiographies and SurgimapSpine software on the computer. Parameters measured included pelvic incidence, sacral slope, pelvic tilt, Lumbar lordosis (LL), thoracic kyphosis, and coronal Cobb angle. SPSS 16.0 software was used for statistical analyses. The means, standard deviations, intraclass and interclass correlation coefficient (ICC), and 95% confidence intervals (CI) were calculated. There was no notable difference between the two tools (P = 0.21) for the coronal Cobb angle. In the sagittal plane parameters, the ICC of intraobserver reliability for the manual measures varied from 0.65 (T2-T5 angle) to 0.95 (LL angle). Further, for SurgimapSpine tool, the ICC ranged from 0.75 to 0.98. No significant difference in intraobserver reliability was found between the two measurements (P > 0.05). As for the interobserver reliability, measurements with SurgimapSpine tool had better ICC (0.71 to 0.98 vs 0.59 to 0.96) and Pearson's coefficient (0.76 to 0.99 vs 0.60 to 0.97). The reliability of SurgimapSpine measures was significantly higher in all parameters except for the coronal Cobb angle where the difference was not significant (P > 0.05). Although the differences between the two methods are very small, the results of this study indicate that the SurgimapSpine measurement is an equivalent measuring tool to the traditional manual in coronal Cobb angle, but is advantageous in spino

  19. Reliability of corneal dynamic scheimpflug analyser measurements in virgin and post-PRK eyes.

    Directory of Open Access Journals (Sweden)

    Xiangjun Chen

    Full Text Available PURPOSE: To determine the measurement reliability of CorVis ST, a dynamic Scheimpflug analyser, in virgin and post-photorefractive keratectomy (PRK eyes and compare the results between these two groups. METHODS: Forty virgin eyes and 42 post-PRK eyes underwent CorVis ST measurements performed by two technicians. Repeatability was evaluated by comparing three consecutive measurements by technician A. Reproducibility was determined by comparing the first measurement by technician A with one performed by technician B. Intraobserver and interobserver intraclass correlation coefficients (ICCs were calculated. Univariate analysis of covariance (ANCOVA was used to compare measured parameters between virgin and post-PRK eyes. RESULTS: The intraocular pressure (IOP, central corneal thickness (CCT and 1st applanation time demonstrated good intraobserver repeatability and interobserver reproducibility (ICC ≧ 0.90 in virgin and post-PRK eyes. The deformation amplitude showed a good or close to good repeatability and reproducibility in both groups (ICC ≧ 0.88. The CCT correlated positively with 1st applanation time (r = 0.437 and 0.483, respectively, p<0.05 and negatively with deformation amplitude (r = -0.384 and -0.375, respectively, p<0.05 in both groups. Compared to post-PRK eyes, virgin eyes showed longer 1st applanation time (7.29 ± 0.21 vs. 6.96 ± 0.17 ms, p<0.05 and lower deformation amplitude (1.06 ± 0.07 vs. 1.17 ± 0.08 mm, p < 0.05. CONCLUSIONS: CorVis ST demonstrated reliable measurements for CCT, IOP, and 1st applanation time, as well as relatively reliable measurement for deformation amplitude in both virgin and post-PRK eyes. There were differences in 1st applanation time and deformation amplitude between virgin and post-PRK eyes, which may reflect corneal biomechanical changes occurring after the surgery in the latter.

  20. Techniques for increasing the reliability of accelerator control system electronics

    International Nuclear Information System (INIS)

    Utterback, J.

    1993-09-01

    As the physical size of modern accelerators becomes larger and larger, the number of required control system circuit boards increases, and the probability of one of those circuit boards failing while in service also increases. In order to do physics, the experimenters need the accelerator to provide beam reliably with as little down time as possible. With the advent of colliding beams physics, reliability becomes even more important due to the fact that a control system failure can cause the loss of painstakingly produced antiprotons. These facts prove the importance of keeping reliability in mind when designing and maintaining accelerator control system electronics

  1. Test-retest reliability of a handheld dynamometer for measurement of isometric cervical muscle strength.

    Science.gov (United States)

    Vannebo, Katrine Tranaas; Iversen, Vegard Moe; Fimland, Marius Steiro; Mork, Paul Jarle

    2018-03-02

    There is a lack of test-retest reliability studies of measurements of cervical muscle strength, taking into account gender and possible learning effects. To investigate test-retest reliability of measurement of maximal isometric cervical muscle strength by handheld dynamometry. Thirty women (age 20-58 years) and 28 men (age 20-60 years) participated in the study. Maximal isometric strength (neck flexion, neck extension, and right/left lateral flexion) was measured on three separate days at least five days apart by one evaluator. Intra-rater consistency tended to improve from day 1-2 measurements to day 2-3 measurements in both women and men. In women, the intra-class correlation coefficients (ICC) for day 2 to day 3 measurements were 0.91 (95% confidence interval [CI], 0.82-0.95) for neck flexion, 0.88 (95% CI, 0.76-0.94) for neck extension, 0.84 (95% CI, 0.68-0.92) for right lateral flexion, and 0.89 (95% CI, 0.78-0.95) for left lateral flexion. The corresponding ICCs among men were 0.86 (95% CI, 0.72-0.93) for neck flexion, 0.93 (95% CI, 0.85-0.97) for neck extension, 0.82 (95% CI, 0.65-0.91) for right lateral flexion and 0.73 (95% CI, 0.50-0.87) for left lateral flexion. This study describes a reliable and easy-to-administer test for assessing maximal isometric cervical muscle strength.

  2. Intra-rater reliability of hallux flexor strength measures using the Nintendo Wii Balance Board.

    Science.gov (United States)

    Quek, June; Treleaven, Julia; Brauer, Sandra G; O'Leary, Shaun; Clark, Ross A

    2015-01-01

    The purpose of this study was to investigate the intra-rater reliability of a new method in combination with the Nintendo Wii Balance Board (NWBB) to measure the strength of hallux flexor muscle. Thirty healthy individuals (age: 34.9 ± 12.9 years, height: 170.4 ± 10.5 cm, weight: 69.3 ± 15.3 kg, female = 15) participated. Repeated testing was completed within 7 days. Participants performed strength testing in sitting using a wooden platform in combination with the NWBB. This new method was set up to selectively recruit an intrinsic muscle of the foot, specifically the flexor hallucis brevis muscle. Statistical analysis was performed using intra-class coefficients and ordinary least product analysis. To estimate measurement error, standard error of measurement (SEM), minimal detectable change (MDC) and percentage error were calculated. Results indicate excellent intra-rater reliability (ICC = 0.982, CI = 0.96-0.99) with an absence of systematic bias. SEM, MDC and percentage error value were 0.5, 1.4 and 12 % respectively. This study demonstrates that a new method in combination with the NWBB application is reliable to measure hallux flexor strength and has potential to be used for future research and clinical application.

  3. Measurement of water absorption capacity in wheat flour by a headspace gas chromatographic technique.

    Science.gov (United States)

    Xie, Wei-Qi; Yu, Kong-Xian; Gong, Yi-Xian

    2018-04-17

    The purpose of this work is to introduce a new method for quantitatively analyzing water absorption capacity in wheat flour by a headspace gas chromatographic technique. This headspace gas chromatographic technique was based on measuring the water vapor released from a series of wheat flour samples with different contents of water addition. According to the different trends between the vapor and wheat flour phase before and after the water absorption capacity in wheat flour, a turning point (corresponding to water absorption capacity in wheat flour) can be obtained by fitting the data of the water gas chromatography peak area from different wheat flour samples. The data showed that the phase equilibrium in the vial can be achieved in 25 min at desired temperature (35°C). The relative standard deviation of the reaction headspace gas chromatographic technique in water absorption capacity determination was within 3.48%, the relative differences has been determined by comparing the water absorption capacity obtained from this new analytical technique with the data from the reference technique (i.e., the filtration method), which are less than 8.92%. The new headspace gas chromatographic method is automated, accurate and be a reliable tool for quantifying water absorption capacity in wheat flour in both laboratory research and mill applications. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. Quantitative measurement of hypertrophic scar: intrarater reliability, sensitivity, and specificity.

    Science.gov (United States)

    Nedelec, Bernadette; Correa, José A; Rachelska, Grazyna; Armour, Alexis; LaSalle, Léo

    2008-01-01

    The comparison of scar evaluation over time requires measurement tools with acceptable intrarater reliability and the ability to discriminate skin characteristics of interest. The objective of this study was to evaluate the intrarater reliability and sensitivity and specificity of the Cutometer, the Mexameter, and the DermaScan C relative to the modified Vancouver Scar Scale (mVSS) in patient-matched normal skin, normal scar (donor sites), and hypertrophic scar (HSc). A single investigator evaluated four tissue types (severe HSc, less severe HSc, donor site, and normal skin) in 30 burn survivors with all four measurement tools. The intraclass correlation coefficient (ICC) for the Cutometer was acceptable (> or =0.75) for the maximum deformation measure for the donor site and normal skin (>0.78) but was below the acceptable range for the HSc sites and all other parameters. The ICC for the Mexameter erythema (>0.75) and melanin index (>0.89) and the DermaScan C total thickness measurement (>0.82) were acceptable for all sites. The ICC for the total of the height, pliability, and vascularity subscales of the mVSS was acceptable (0.81) for normal scar but below the acceptable range for the scar sites. The DermaScan C was clearly able to discriminate HSc from normal scar and normal skin based on the total thickness measure. The Cutometer was less discriminating but was still able to discriminate HSc from normal scar and normal skin. The Mexameter erythema index was not a good discriminator of HSc and normal scar. Receiver operating characteristic curves were generated to establish the best cutoff point for the DermaScan C total thickness and the Cutometer maximum deformation, which were 2.034 and 0.387 mm, respectively. This study showed that although the Cutometer, the DermaScan C, and the Mexameter have measurement properties that make them attractive substitutes for the mVSS, caution must be used when interpreting results since the Cutometer has a ceiling effect when

  5. [Reliability study in the measurement of the cusp inclination angle of a chairside digital model].

    Science.gov (United States)

    Xinggang, Liu; Xiaoxian, Chen

    2018-02-01

    This study aims to evaluate the reliability of the software Picpick in the measurement of the cusp inclination angle of a digital model. Twenty-one trimmed models were used as experimental objects. The chairside digital impression was then used for the acquisition of 3D digital models, and the software Picpick was employed for the measurement of the cusp inclination of these models. The measurements were repeated three times, and the results were compared with a gold standard, which was a manually measured experimental model cusp angle. The intraclass correlation coefficient (ICC) was calculated. The paired t test value of the two measurement methods was 0.91. The ICCs between the two measurement methods and three repeated measurements were greater than 0.9. The digital model achieved a smaller coefficient of variation (9.9%). The software Picpick is reliable in measuring the cusp inclination of a digital model.

  6. Reliability of perceived neighbourhood conditions and the effects of measurement error on self-rated health across urban and rural neighbourhoods.

    Science.gov (United States)

    Pruitt, Sandi L; Jeffe, Donna B; Yan, Yan; Schootman, Mario

    2012-04-01

    Limited psychometric research has examined the reliability of self-reported measures of neighbourhood conditions, the effect of measurement error on associations between neighbourhood conditions and health, and potential differences in the reliabilities between neighbourhood strata (urban vs rural and low vs high poverty). We assessed overall and stratified reliability of self-reported perceived neighbourhood conditions using five scales (social and physical disorder, social control, social cohesion, fear) and four single items (multidimensional neighbouring). We also assessed measurement error-corrected associations of these conditions with self-rated health. Using random-digit dialling, 367 women without breast cancer (matched controls from a larger study) were interviewed twice, 2-3 weeks apart. Test-retest (intraclass correlation coefficients (ICC)/weighted κ) and internal consistency reliability (Cronbach's α) were assessed. Differences in reliability across neighbourhood strata were tested using bootstrap methods. Regression calibration corrected estimates for measurement error. All measures demonstrated satisfactory internal consistency (α ≥ 0.70) and either moderate (ICC/κ=0.41-0.60) or substantial (ICC/κ=0.61-0.80) test-retest reliability in the full sample. Internal consistency did not differ by neighbourhood strata. Test-retest reliability was significantly lower among rural (vs urban) residents for two scales (social control, physical disorder) and two multidimensional neighbouring items; test-retest reliability was higher for physical disorder and lower for one multidimensional neighbouring item among the high (vs low) poverty strata. After measurement error correction, the magnitude of associations between neighbourhood conditions and self-rated health were larger, particularly in the rural population. Research is needed to develop and test reliable measures of perceived neighbourhood conditions relevant to the health of rural populations.

  7. An extended laser flash technique for thermal diffusivity measurement of high-temperature materials

    Science.gov (United States)

    Shen, F.; Khodadadi, J. M.

    1993-01-01

    Knowledge of thermal diffusivity data for high-temperature materials (solids and liquids) is very important in analyzing a number of processes, among them solidification, crystal growth, and welding. However, reliable thermal diffusivity versus temperature data, particularly those for high-temperature liquids, are still far from complete. The main measurement difficulties are due to the presence of convection and the requirement for a container. Fortunately, the availability of levitation techniques has made it possible to solve the containment problem. Based on the feasibility of the levitation technology, a new laser flash technique which is applicable to both levitated liquid and solid samples is being developed. At this point, the analysis for solid samples is near completion and highlights of the technique are presented here. The levitated solid sample which is assumed to be a sphere is subjected to a very short burst of high power radiant energy. The temperature of the irradiated surface area is elevated and a transient heat transfer process takes place within the sample. This containerless process is a two-dimensional unsteady heat conduction problem. Due to the nonlinearity of the radiative plus convective boundary condition, an analytic solution cannot be obtained. Two options are available at this point. Firstly, the radiation boundary condition can be linearized, which then accommodates a closed-form analytic solution. Comparison of the analytic curves for the temperature rise at different points to the experimentally-measured values will then provide the thermal diffusivity values. Secondly, one may set up an inverse conduction problem whereby experimentally obtained surface temperature history is used as the boundary conditions. The thermal diffusivity can then be elevated by minimizing the difference between the real heat flux boundary condition (radiation plus convection) and the measurements. Status of an experimental study directed at measuring the

  8. Insights from Synthetic Star-forming Regions. III. Calibration of Measurement and Techniques of Star Formation Rates

    Energy Technology Data Exchange (ETDEWEB)

    Koepferl, Christine M.; Robitaille, Thomas P. [Max Planck Institute for Astronomy, Königstuhl 17, D-69117 Heidelberg (Germany); Dale, James E., E-mail: koepferl@usm.lmu.de [University Observatory Munich, Scheinerstr. 1, D-81679 Munich (Germany)

    2017-11-01

    Through an extensive set of realistic synthetic observations (produced in Paper I), we assess in this part of the paper series (Paper III) how the choice of observational techniques affects the measurement of star formation rates (SFRs) in star-forming regions. We test the accuracy of commonly used techniques and construct new methods to extract the SFR, so that these findings can be applied to measure the SFR in real regions throughout the Milky Way. We investigate diffuse infrared SFR tracers such as those using 24 μ m, 70 μ m and total infrared emission, which have been previously calibrated for global galaxy scales. We set up a toy model of a galaxy and show that the infrared emission is consistent with the intrinsic SFR using extra-galactic calibrated laws (although the consistency does not prove their reliability). For local scales, we show that these techniques produce completely unreliable results for single star-forming regions, which are governed by different characteristic timescales. We show how calibration of these techniques can be improved for single star-forming regions by adjusting the characteristic timescale and the scaling factor and give suggestions of new calibrations of the diffuse star formation tracers. We show that star-forming regions that are dominated by high-mass stellar feedback experience a rapid drop in infrared emission once high-mass stellar feedback is turned on, which implies different characteristic timescales. Moreover, we explore the measured SFRs calculated directly from the observed young stellar population. We find that the measured point sources follow the evolutionary pace of star formation more directly than diffuse star formation tracers.

  9. Quantitative outcome measures for systemic sclerosis-related Microangiopathy - Reliability of image acquisition in Nailfold Capillaroscopy.

    Science.gov (United States)

    Dinsdale, Graham; Moore, Tonia; O'Leary, Neil; Berks, Michael; Roberts, Christopher; Manning, Joanne; Allen, John; Anderson, Marina; Cutolo, Maurizio; Hesselstrand, Roger; Howell, Kevin; Pizzorni, Carmen; Smith, Vanessa; Sulli, Alberto; Wildt, Marie; Taylor, Christopher; Murray, Andrea; Herrick, Ariane L

    2017-09-01

    Nailfold capillaroscopic parameters hold increasing promise as outcome measures for clinical trials in systemic sclerosis (SSc). Their inclusion as outcomes would often naturally require capillaroscopy images to be captured at several time points during any one study. Our objective was to assess repeatability of image acquisition (which has been little studied), as well as of measurement. 41 patients (26 with SSc, 15 with primary Raynaud's phenomenon) and 10 healthy controls returned for repeat high-magnification (300×) videocapillaroscopy mosaic imaging of 10 digits one week after initial imaging (as part of a larger study of reliability). Images were assessed in a random order by an expert blinded observer and 4 outcome measures extracted: (1) overall image grade and then (where possible) distal vessel locations were marked, allowing (2) vessel density (across the whole nailfold) to be calculated (3) apex width measurement and (4) giant vessel count. Intra-rater, intra-visit and intra-rater inter-visit (baseline vs. 1week) reliability were examined in 475 and 392 images respectively. A linear, mixed-effects model was used to estimate variance components, from which intra-class correlation coefficients (ICCs) were determined. Intra-visit and inter-visit reliability estimates (ICCs) were (respectively): overall image grade, 0.97 and 0.90; vessel density, 0.92 and 0.65; mean vessel width, 0.91 and 0.79; presence of giant capillary, 0.68 and 0.56. These estimates were conditional on each parameter being measurable. Within-operator image analysis and acquisition are reproducible. Quantitative nailfold capillaroscopy, at least with a single observer, provides reliable outcome measures for clinical studies including randomised controlled trials. Copyright © 2017 Elsevier Inc. All rights reserved.

  10. Vessel size measurements in angiograms: A comparison of techniques

    International Nuclear Information System (INIS)

    Hoffmann, Kenneth R.; Nazareth, Daryl P.; Miskolczi, Laszlo; Gopal, Anant; Wang Zhou; Rudin, Stephen; Bednarek, Daniel R.

    2002-01-01

    As interventional procedures become more complicated, the need for accurate quantitative vascular information increases. In response to this need, many commercial vendors provide techniques for measurement of vessel sizes, usually based on derivative techniques. In this study, we investigate the accuracy of several techniques used in the measurement of vessel size. Simulated images of vessels having circular cross sections were generated and convolved with various focal spot distributions taking into account the magnification. These vessel images were then convolved with Gaussian image detector line spread functions (LSFs). Additionally, images of a phantom containing vessels with a range of diameters were acquired for the 4.5'', 6'', 9'', and 12'' modes of an image intensifier-TV (II-TV) system. Vessel sizes in the images were determined using a first-derivative technique, a second-derivative technique, a linear combination of these two measured sizes, a thresholding technique, a densitometric technique, and a model-based technique. For the same focal spot size, the shape of the focal spot distribution does not affect measured vessel sizes except at large magnifications. For vessels with diameters larger than the full-width-at-half-maximum (FWHM) of the LSF, accurate vessel sizes (errors ∼0.1 mm) could be obtained by using an average of sizes determined by the first and second derivatives. For vessels with diameters smaller than the FWHM of the LSF, the densitometric and model-based techniques can provide accurate vessel sizes when these techniques are properly calibrated

  11. Radiotracer techniques for measuring fluid flow and calibrating flow meters

    International Nuclear Information System (INIS)

    Cooper, E.L.

    1987-08-01

    Radiotracer techniques can be used to measure accurately both gas and liquid flow rates under operating conditions in a wide range of flow systems. They are ideally suited for calibrating flow meters as well as for measuring unmetered flows in industrial plants. Applications of these techniques range from measuring the flows of fuels and process fluids for energy and mass balance studies to measuring the flows of liquid and airborne effluents for pollution control. This report describes the various radiotracer techniques which can be used to measure fluid flows. The range of application and inherent accuracy of each technique is discussed

  12. The Sine Method: An Alternative Height Measurement Technique

    Science.gov (United States)

    Don C. Bragg; Lee E. Frelich; Robert T. Leverett; Will Blozan; Dale J. Luthringer

    2011-01-01

    Height is one of the most important dimensions of trees, but few observers are fully aware of the consequences of the misapplication of conventional height measurement techniques. A new approach, the sine method, can improve height measurement by being less sensitive to the requirements of conventional techniques (similar triangles and the tangent method). We studied...

  13. Optical Measurement Techniques for Rocket Engine Testing and Component Applications: Digital Image Correlation and Dynamic Photogrammetry

    Science.gov (United States)

    Gradl, Paul

    2016-01-01

    NASA Marshall Space Flight Center (MSFC) has been advancing dynamic optical measurement systems, primarily Digital Image Correlation, for extreme environment rocket engine test applications. The Digital Image Correlation (DIC) technology is used to track local and full field deformations, displacement vectors and local and global strain measurements. This technology has been evaluated at MSFC through lab testing to full scale hotfire engine testing of the J-2X Upper Stage engine at Stennis Space Center. It has been shown to provide reliable measurement data and has replaced many traditional measurement techniques for NASA applications. NASA and AMRDEC have recently signed agreements for NASA to train and transition the technology to applications for missile and helicopter testing. This presentation will provide an overview and progression of the technology, various testing applications at NASA MSFC, overview of Army-NASA test collaborations and application lessons learned about Digital Image Correlation.

  14. System Reliability Engineering

    International Nuclear Information System (INIS)

    Lim, Tae Jin

    2005-02-01

    This book tells of reliability engineering, which includes quality and reliability, reliability data, importance of reliability engineering, reliability and measure, the poisson process like goodness of fit test and the poisson arrival model, reliability estimation like exponential distribution, reliability of systems, availability, preventive maintenance such as replacement policies, minimal repair policy, shock models, spares, group maintenance and periodic inspection, analysis of common cause failure, and analysis model of repair effect.

  15. The Myotonometer: Not a Valid Measurement Tool for Active Hamstring Musculotendinous Stiffness.

    Science.gov (United States)

    Pamukoff, Derek N; Bell, Sarah E; Ryan, Eric D; Blackburn, J Troy

    2016-05-01

    Hamstring musculotendinous stiffness (MTS) is associated with lower-extremity injury risk (ie, hamstring strain, anterior cruciate ligament injury) and is commonly assessed using the damped oscillatory technique. However, despite a preponderance of studies that measure MTS reliably in laboratory settings, there are no valid clinical measurement tools. A valid clinical measurement technique is needed to assess MTS and permit identification of individuals at heightened risk of injury and track rehabilitation progress. To determine the validity and reliability of the Myotonometer for measuring active hamstring MTS. Descriptive laboratory study. Laboratory. 33 healthy participants (15 men, age 21.33 ± 2.94 y, height 172.03 ± 16.36 cm, mass 74.21 ± 16.36 kg). Hamstring MTS was assessed using the damped oscillatory technique and the Myotonometer. Intraclass correlations were used to determine the intrasession, intersession, and interrater reliability of the Myotonometer. Criterion validity was assessed via Pearson product-moment correlation between MTS measures obtained from the Myotonometer and from the damped oscillatory technique. The Myotonometer demonstrated good intrasession (ICC3,1 = .807) and interrater reliability (ICC2,k = .830) and moderate intersession reliability (ICC2,k = .693). However, it did not provide a valid measurement of MTS compared with the damped oscillatory technique (r = .346, P = .061). The Myotonometer does not provide a valid measure of active hamstring MTS. Although the Myotonometer does not measure active MTS, it possesses good reliability and portability and could be used clinically to measure tissue compliance, muscle tone, or spasticity associated with multiple musculoskeletal disorders. Future research should focus on portable and clinically applicable tools to measure active hamstring MTS in efforts to prevent and monitor injuries.

  16. Reliability analysis of reactor inspection robot(RIROB)

    International Nuclear Information System (INIS)

    Eom, H. S.; Kim, J. H.; Lee, J. C.; Choi, Y. R.; Moon, S. S.

    2002-05-01

    This report describes the method and the result of the reliability analysis of RIROB developed in Korea Atomic Energy Research Institute. There are many classic techniques and models for the reliability analysis. These techniques and models have been used widely and approved in other industries such as aviation and nuclear industry. Though these techniques and models have been approved in real fields they are still insufficient for the complicated systems such RIROB which are composed of computer, networks, electronic parts, mechanical parts, and software. Particularly the application of these analysis techniques to digital and software parts of complicated systems is immature at this time thus expert judgement plays important role in evaluating the reliability of the systems at these days. In this report we proposed a method which combines diverse evidences relevant to the reliability to evaluate the reliability of complicated systems such as RIROB. The proposed method combines diverse evidences and performs inference in formal and in quantitative way by using the benefits of Bayesian Belief Nets (BBN)

  17. Assessment of the accuracy and reliability of the Topcon CT80 non-contact tonometer.

    Science.gov (United States)

    Ogbuehi, Kelechi C

    2006-09-01

    The reliability of non-contact tonometers has been reported extensively in the literature. This study was designed to assess reliability of the new Topcon CT80 non-contact tonometer in normotensive subjects, using the Goldmann tonometer as the standard. The accuracy of the Topcon CT 80 non-contact tonometer was assessed by comparing its IOP assessments with those of the Goldmann applanation tonometer, on 60 right eyes of young healthy subjects with normal intraocular pressures. Each subject's intraocular pressure was assessed with each technique on two separate occasions, one week apart. The reliability of each technique was determined by the assessment of its inter-session repeatability using the Bland-Altman method. The 95 per cent limits of agreement for the two methods were also determined. No statistically significant difference was found between the average intraocular pressures measured with the two techniques (p > 0.05). The inter-session repeatability indices for the two techniques did not differ significantly (p > 0.05). The mean difference in intraocular measurements between the two techniques was 0.2 +/- 1.5 mmHg (mean +/- SD) and the 95 per cent limits of agreement were -3.14 and +2.74 mmHg, with the non-contact tonometer returning higher readings than the Goldmann tonometer. In this sample of normotensive subjects, the Topcon CT80 non-contact tonometer proved to be accurate and as reliable as the Goldmann tonometer in the assessment of intraocular pressure. Thus, it can be used as an objective clinical method for the assessment of normal intraocular pressure.

  18. Inertial Measurement Units for Clinical Movement Analysis: Reliability and Concurrent Validity

    Directory of Open Access Journals (Sweden)

    Mohammad Al-Amri

    2018-02-01

    Full Text Available The aim of this study was to investigate the reliability and concurrent validity of a commercially available Xsens MVN BIOMECH inertial-sensor-based motion capture system during clinically relevant functional activities. A clinician with no prior experience of motion capture technologies and an experienced clinical movement scientist each assessed 26 healthy participants within each of two sessions using a camera-based motion capture system and the MVN BIOMECH system. Participants performed overground walking, squatting, and jumping. Sessions were separated by 4 ± 3 days. Reliability was evaluated using intraclass correlation coefficient and standard error of measurement, and validity was evaluated using the coefficient of multiple correlation and the linear fit method. Day-to-day reliability was generally fair-to-excellent in all three planes for hip, knee, and ankle joint angles in all three tasks. Within-day (between-rater reliability was fair-to-excellent in all three planes during walking and squatting, and poor-to-high during jumping. Validity was excellent in the sagittal plane for hip, knee, and ankle joint angles in all three tasks and acceptable in frontal and transverse planes in squat and jump activity across joints. Our results suggest that the MVN BIOMECH system can be used by a clinician to quantify lower-limb joint angles in clinically relevant movements.

  19. Recent developments in magnet measuring techniques

    International Nuclear Information System (INIS)

    Billan, J.; Henrichsen, K.N.; Walckiers, L.

    1985-01-01

    The main problems related to magnetic measurements of particle accelerator components are discussed. Measurements of the properties of magnetic materials as well as the measurements of field distribution in the electromagnets for the Large Electron-Positron Collider (LEP) are illustrated. The fluxmeter method is extensively employed in this work. The impact of recent advances in electronic technology on measurement techniques is explained. Magnetic measurements (including the harmonic coil method) can be performed with improved accuracy applying modern technology to the classical methods. New methods for the non-destructive testing of magnetic materials and for the measurement of magnetic geometry are described. (orig.) [de

  20. The reliability and validity of fatigue measures during short-duration maximal-intensity intermittent cycling.

    Science.gov (United States)

    Glaister, Mark; Stone, Michael H; Stewart, Andrew M; Hughes, Michael; Moir, Gavin L

    2004-08-01

    The purpose of the present study was to assess the reliability and validity of fatigue measures, as derived from 4 separate formulae, during tests of repeat sprint ability. On separate days over a 3-week period, 2 groups of 7 recreationally active men completed 6 trials of 1 of 2 maximal (20 x 5 seconds) intermittent cycling tests with contrasting recovery periods (10 or 30 seconds). All trials were conducted on a friction-braked cycle ergometer, and fatigue scores were derived from measures of mean power output for each sprint. Apart from formula 1, which calculated fatigue from the percentage difference in mean power output between the first and last sprint, all remaining formulae produced fatigue scores that showed a reasonably good level of test-retest reliability in both intermittent test protocols (intraclass correlation range: 0.78-0.86; 95% likely range of true values: 0.54-0.97). Although between-protocol differences in the magnitude of the fatigue scores suggested good construct validity, within-protocol differences highlighted limitations with each formula. Overall, the results support the use of the percentage decrement score as the most valid and reliable measure of fatigue during brief maximal intermittent work.

  1. Reliability and Validity of an Internet-based Questionnaire Measuring Lifetime Physical Activity

    OpenAIRE

    De Vera, Mary A.; Ratzlaff, Charles; Doerfling, Paul; Kopec, Jacek

    2010-01-01

    Lifetime exposure to physical activity is an important construct for evaluating associations between physical activity and disease outcomes, given the long induction periods in many chronic diseases. The authors' objective in this study was to evaluate the measurement properties of the Lifetime Physical Activity Questionnaire (L-PAQ), a novel Internet-based, self-administered instrument measuring lifetime physical activity, among Canadian men and women in 2005–2006. Reliability was examined u...

  2. Some new hydraulic and tracer measurement techniques for heterogeneous aquifer formations

    International Nuclear Information System (INIS)

    Ptak, T.; Teutsch, G.

    1990-01-01

    Groundwater contamination assessment and remediation activities demand reliable techniques for the determination of the governing aquifer parameters and their spatial distribution. In order to define guidelines and recommendations, some existing underground investigation techniques were tested and new methods have been developed as a part of the research program at the Horkheimer Insel experimental field site. In this paper, some new developed field and laboratory techniques are introduced and the results compared for two example monitoring wells located in the northern part of the field site. It is shown that highly conductive and highly heterogeneous aquifers demand high resolution investigation techniques. For transport predictions, new methods are needed that are able to detect preferential flow paths. Results from multilevel tracer tests show that simple analytical interpretations are not valid for this type of aquifer. (Author) (8 refs., 12 figs., tab.)

  3. Error reduction techniques for measuring long synchrotron mirrors

    International Nuclear Information System (INIS)

    Irick, S.

    1998-07-01

    Many instruments and techniques are used for measuring long mirror surfaces. A Fizeau interferometer may be used to measure mirrors much longer than the interferometer aperture size by using grazing incidence at the mirror surface and analyzing the light reflected from a flat end mirror. Advantages of this technique are data acquisition speed and use of a common instrument. Disadvantages are reduced sampling interval, uncertainty of tangential position, and sagittal/tangential aspect ratio other than unity. Also, deep aspheric surfaces cannot be measured on a Fizeau interferometer without a specially made fringe nulling holographic plate. Other scanning instruments have been developed for measuring height, slope, or curvature profiles of the surface, but lack accuracy for very long scans required for X-ray synchrotron mirrors. The Long Trace Profiler (LTP) was developed specifically for long x-ray mirror measurement, and still outperforms other instruments, especially for aspheres. Thus, this paper focuses on error reduction techniques for the LTP

  4. Assessing the Reliability of Curriculum-Based Measurement: An Application of Latent Growth Modeling

    Science.gov (United States)

    Yeo, Seungsoo; Kim, Dong-Il; Branum-Martin, Lee; Wayman, Miya Miura; Espin, Christine A.

    2012-01-01

    The purpose of this study was to demonstrate the use of Latent Growth Modeling (LGM) as a method for estimating reliability of Curriculum-Based Measurement (CBM) progress-monitoring data. The LGM approach permits the error associated with each measure to differ at each time point, thus providing an alternative method for examining of the…

  5. Electronics reliability calculation and design

    CERN Document Server

    Dummer, Geoffrey W A; Hiller, N

    1966-01-01

    Electronics Reliability-Calculation and Design provides an introduction to the fundamental concepts of reliability. The increasing complexity of electronic equipment has made problems in designing and manufacturing a reliable product more and more difficult. Specific techniques have been developed that enable designers to integrate reliability into their products, and reliability has become a science in its own right. The book begins with a discussion of basic mathematical and statistical concepts, including arithmetic mean, frequency distribution, median and mode, scatter or dispersion of mea

  6. Reliability, precision, and gender differences in knee internal/external rotation proprioception measurements.

    Science.gov (United States)

    Nagai, Takashi; Sell, Timothy C; Abt, John P; Lephart, Scott M

    2012-11-01

    To develop and assess the reliability and precision of knee internal/external rotation (IR/ER) threshold to detect passive motion (TTDPM) and determine if gender differences exist. Test-retest for the reliability/precision and cross-sectional for gender comparisons. University neuromuscular and human performance research laboratory. Ten subjects for the reliability and precision aim. Twenty subjects (10 males and 10 females) for gender comparisons. All TTDPM tests were performed using a multi-mode dynamometer. Subjects performed TTDPM at two knee positions (near IR or ER end-range). Intraclass correlation coefficient (ICC (3,k)) and standard error of measurement (SEM) were used to evaluate the reliability and precision. Independent t-tests were used to compare genders. TTDPM toward IR and ER at two knee positions. Intrasession and intersession reliability and precision were good (ICC=0.68-0.86; SEM=0.22°-0.37°). Females had significantly diminished TTDPM toward IR at IR-test position (males: 0.77°±0.14°, females: 1.18°±0.46°, p=0.021) and TTDPM toward IR at the ER-test position (males: 0.87°±0.13°, females: 1.36°±0.58°, p=0.026). No other significant gender differences were found (p>0.05). The current IR/ER TTDPM methods are reliable and accurate for the test-retest or cross-section research design. Gender differences were found toward IR where the ACL acts as the secondary restraint. Copyright © 2011 Elsevier Ltd. All rights reserved.

  7. AECL's reliability and maintainability program

    International Nuclear Information System (INIS)

    Wolfe, W.A.; Nieuwhof, G.W.E.

    1976-05-01

    AECL's reliability and maintainability program for nuclear generating stations is described. How the various resources of the company are organized to design and construct stations that operate reliably and safely is shown. Reliability and maintainability includes not only special mathematically oriented techniques, but also the technical skills and organizational abilities of the company. (author)

  8. Reliability of non-destructive test techniques in the inspection of pipelines used in the oil industry

    International Nuclear Information System (INIS)

    Carvalho, A.A.; Rebello, J.M.A.; Souza, M.P.V.; Sagrilo, L.V.S.; Soares, S.D.

    2008-01-01

    The aim of this work is to evaluate the reliability of non-destructive test (NDT) techniques for the inspection of pipeline welds employed in the petroleum industry. Radiography, manual and automatic ultrasonic techniques using pulse-echo and time of flight diffraction (TOFD) were employed. Three classes of defects were analyzed: lack of penetration (LP), lack of fusion (LF) and undercut (UC). The tests were carried out on specimen made from pipelines containing defects, which had been artificially inserted on laying the weld bead. The results showed the superiority of the automatic ultrasonic tests for defect detection compared with the manual ultrasonic and radiographic tests. Additionally, artificial neural networks (ANN) were used in the detection and automatic classification of the defects

  9. Reliability of length measurements collected by community nurses and health volunteers in rural growth monitoring and promotion services.

    Science.gov (United States)

    Laar, Matilda E; Marquis, Grace S; Lartey, Anna; Gray-Donald, Katherine

    2018-02-17

    Length measurements are important in growth, monitoring and promotion (GMP) for the surveillance of a child's weight-for-length and length-for-age. These two indices provide an indication of a child's risk of becoming wasted or stunted, and are more informative about a child's growth than the widely used weight-for-age index (underweight). Although the introduction of length measurements in GMP is recommended by the World Health Organization, concerns about the reliability of length measurements collected in rural outreach settings have been expressed by stakeholders. Our aim was to describe the reliability and challenges associated with community health personnel measuring length for rural outreach GMP activities. Two reliability studies (A and B), using 10 children less than 24 months each, were conducted in the GMP services of a rural district in Ghana. Fifteen nurses and 15 health volunteers (HV) with no prior experience in length measurements were trained. Intra- and inter-observer technical error of measurement (TEM), average bias from expert anthropometrist, and coefficient of reliability (R) of length measurements were assessed and compared across sessions. Observations and interviews were used to understand the ability and experiences of health personnel with measuring length at outreach GMP. Inter-observer TEM was larger than intra-observer TEM for both nurses and HV at both sessions and was unacceptably (compared to error standards) high in both groups at both time points. Average biases from expert's measurements were within acceptable limits, however, both groups tended to underestimate length measurements. The R for lengths collected by nurses (92.3%) was higher at session B compared to that of HV (87.5%). Length measurements taken by nurses and HV, and those taken by an experienced anthropometrist at GMP sessions were of moderate agreement (kappa = 0.53, p reliability of length measurements improved after two refresher trainings for nurses but

  10. Reliability and maintainability assessment factors for reliable fault-tolerant systems

    Science.gov (United States)

    Bavuso, S. J.

    1984-01-01

    A long term goal of the NASA Langley Research Center is the development of a reliability assessment methodology of sufficient power to enable the credible comparison of the stochastic attributes of one ultrareliable system design against others. This methodology, developed over a 10 year period, is a combined analytic and simulative technique. An analytic component is the Computer Aided Reliability Estimation capability, third generation, or simply CARE III. A simulative component is the Gate Logic Software Simulator capability, or GLOSS. The numerous factors that potentially have a degrading effect on system reliability and the ways in which these factors that are peculiar to highly reliable fault tolerant systems are accounted for in credible reliability assessments. Also presented are the modeling difficulties that result from their inclusion and the ways in which CARE III and GLOSS mitigate the intractability of the heretofore unworkable mathematics.

  11. Complex technique for materials hardness measurement

    Energy Technology Data Exchange (ETDEWEB)

    Krashchenko, V P; Oksametnaya, O B

    1984-01-01

    A review of existing methods of measurement of material hardness in national and foreign practice has been made. A necessity of improving the technique of material hardness measurement in a wide temperature range and insuring load change with indenting, continuity of imprint application, smooth changing of temperatures along a sample length, and deformation rate control has been noted.

  12. Ultrasonic technique for measuring porosity of plasma-sprayed alumina coatings

    Science.gov (United States)

    Parthasarathi, S.; Tittmann, B. R.; Onesto, E. J.

    1997-12-01

    Porosity is an important factor in plasma-sprayed coatings, especially ceramic coatings. Excessive poros-ity can adversely affect the performance of the coated component in various ways. An ultrasonic nonde-structive measurement technique has been developed to measure porosity in plasma-sprayed alumina coatings. The technique is generic and can be extended to other ceramic coating systems. To test the tech-nique, freestanding alumina coatings with varying levels of porosity were fabricated via plasma spray. Samples with varying porosity, obtained through innovative fabrication techniques, were used to gener-ate a calibration curve. The ultrasonic velocity in the low-frequency range was found to be dependent on the density of freestanding coatings (measured via Archimedian techniques). This dependence is the basis of the development of a technique to measure the density of coatings.

  13. Comparison of the THERP quantitative tables with the human reliability analysis techniques of second generation

    International Nuclear Information System (INIS)

    Alvarenga, Marco Antonio Bayout; Fonseca, Renato Alves

    2009-01-01

    The methodology THERP is classified as a Human Reliability Analysis (HRA) technique of first generation and its emergence was an important initial step for the development of HRA techniques in the industry. Due to the fact of being a first generation technique, THERP quantification tables of human errors are based on a taxonomy that does not take into account the human errors mechanisms. Concerning the three cognitive levels in the Rasmussen framework for the cognitive information processing in human beings, THERP deals in most cases with errors that happen in the perceptual-motor level (stimulus-response). In the rules level, this technique can work better using the time dependent probabilities curves of diagnosis errors, obtained in nuclear power plants simulators. Nevertheless, this is done without processing any error mechanisms. Another deficiency is the fact that the performance shaping factors are in limited number. Furthermore, the influences (predictable or not) of operational context, arising from operational deviations of the most probable (in terms of occurrence probabilities) standard scenarios beside the consequent operational tendencies (operator actions) are not estimated. This work makes a critical analysis of these deficiencies and it points out possible solutions in order to modify the THERP tables, seeking a realistic quantification, that does not underestimate or overestimate the human errors probabilities when applying the HRA techniques to nuclear power plants. The critical analysis is accomplished through a qualitative comparison between THERP, a HRA technique of first generation, with CREAM, as well as ATHEANA, which are HRA techniques of second generation. (author)

  14. Comparison of the THERP quantitative tables with the human reliability analysis techniques of second generation

    Energy Technology Data Exchange (ETDEWEB)

    Alvarenga, Marco Antonio Bayout; Fonseca, Renato Alves [Comissao Nacional de Energia Nuclear (CNEN), Rio de Janeiro, RJ (Brazil)], e-mail: bayout@cnen.gov.br, e-mail: rfonseca@cnen.gov.br

    2009-07-01

    The methodology THERP is classified as a Human Reliability Analysis (HRA) technique of first generation and its emergence was an important initial step for the development of HRA techniques in the industry. Due to the fact of being a first generation technique, THERP quantification tables of human errors are based on a taxonomy that does not take into account the human errors mechanisms. Concerning the three cognitive levels in the Rasmussen framework for the cognitive information processing in human beings, THERP deals in most cases with errors that happen in the perceptual-motor level (stimulus-response). In the rules level, this technique can work better using the time dependent probabilities curves of diagnosis errors, obtained in nuclear power plants simulators. Nevertheless, this is done without processing any error mechanisms. Another deficiency is the fact that the performance shaping factors are in limited number. Furthermore, the influences (predictable or not) of operational context, arising from operational deviations of the most probable (in terms of occurrence probabilities) standard scenarios beside the consequent operational tendencies (operator actions) are not estimated. This work makes a critical analysis of these deficiencies and it points out possible solutions in order to modify the THERP tables, seeking a realistic quantification, that does not underestimate or overestimate the human errors probabilities when applying the HRA techniques to nuclear power plants. The critical analysis is accomplished through a qualitative comparison between THERP, a HRA technique of first generation, with CREAM, as well as ATHEANA, which are HRA techniques of second generation. (author)

  15. Multidisciplinary System Reliability Analysis

    Science.gov (United States)

    Mahadevan, Sankaran; Han, Song; Chamis, Christos C. (Technical Monitor)

    2001-01-01

    The objective of this study is to develop a new methodology for estimating the reliability of engineering systems that encompass multiple disciplines. The methodology is formulated in the context of the NESSUS probabilistic structural analysis code, developed under the leadership of NASA Glenn Research Center. The NESSUS code has been successfully applied to the reliability estimation of a variety of structural engineering systems. This study examines whether the features of NESSUS could be used to investigate the reliability of systems in other disciplines such as heat transfer, fluid mechanics, electrical circuits etc., without considerable programming effort specific to each discipline. In this study, the mechanical equivalence between system behavior models in different disciplines are investigated to achieve this objective. A new methodology is presented for the analysis of heat transfer, fluid flow, and electrical circuit problems using the structural analysis routines within NESSUS, by utilizing the equivalence between the computational quantities in different disciplines. This technique is integrated with the fast probability integration and system reliability techniques within the NESSUS code, to successfully compute the system reliability of multidisciplinary systems. Traditional as well as progressive failure analysis methods for system reliability estimation are demonstrated, through a numerical example of a heat exchanger system involving failure modes in structural, heat transfer and fluid flow disciplines.

  16. Radiological findings for hip dysplasia at skeletal maturity. Validation of digital and manual measurement techniques.

    Science.gov (United States)

    Engesæter, Ingvild Øvstebø; Laborie, Lene Bjerke; Lehmann, Trude Gundersen; Sera, Francesco; Fevang, Jonas; Pedersen, Douglas; Morcuende, José; Lie, Stein Atle; Engesæter, Lars Birger; Rosendahl, Karen

    2012-07-01

    To report on intra-observer, inter-observer, and inter-method reliability and agreement for radiological measurements used in the diagnosis of hip dysplasia at skeletal maturity, as obtained by a manual and a digital measurement technique. Pelvic radiographs from 95 participants (56 females) in a follow-up hip study of 18- to 19-year-old patients were included. Eleven radiological measurements relevant for hip dysplasia (Sharp's, Wiberg's, and Ogata's angles; acetabular roof angle of Tönnis; articulo-trochanteric distance; acetabular depth-width ratio; femoral head extrusion index; maximum teardrop width; and the joint space width in three different locations) were validated. Three observers measured the radiographs using both a digital measurement program and manually in AgfaWeb1000. Inter-method and inter- and intra-observer agreement were analyzed using the mean differences between the readings/readers, establishing the 95% limits of agreement. We also calculated the minimum detectable change and the intra-class correlation coefficient. Large variations among different radiological measurements were demonstrated. However, the variation was not related to the use of either the manual or digital measurement technique. For measurements with greater absolute values (Sharp's angle, femoral head extrusion index, and acetabular depth-width ratio) the inter- and intra-observer and inter-method agreements were better as compared to measurements with lower absolute values (acetabular roof angle, teardrop and joint space width). The inter- and intra-observer variation differs notably across different radiological measurements relevant for hip dysplasia at skeletal maturity, a fact that should be taken into account in clinical practice. The agreement between the manual and digital methods is good.

  17. Radiological findings for hip dysplasia at skeletal maturity. Validation of digital and manual measurement techniques

    Energy Technology Data Exchange (ETDEWEB)

    Engesaeter, Ingvild Oevsteboe [University of Bergen, Department of Surgical Sciences, Bergen (Norway); Haukeland University Hospital, Department of Orthopaedic Surgery, Bergen (Norway); Haukeland University Hospital, Department of Radiology, Bergen (Norway); Haukeland University Hospital, The Norwegian Arthroplasty Register, Department of Orthopaedic Surgery, Bergen (Norway); Laborie, Lene Bjerke; Rosendahl, Karen [University of Bergen, Department of Surgical Sciences, Bergen (Norway); Haukeland University Hospital, Department of Radiology, Bergen (Norway); Lehmann, Trude Gundersen; Fevang, Jonas; Engesaeter, Lars Birger [University of Bergen, Department of Surgical Sciences, Bergen (Norway); Haukeland University Hospital, Department of Orthopaedic Surgery, Bergen (Norway); Sera, Francesco [University College London Institute of Child Health, Medical Research Council Centre of Epidemiology for Child Health, London (United Kingdom); Pedersen, Douglas; Morcuende, Jose [University of Iowa Hospital and Clinics, Department of Orthopaedics and Rehabilitation, Iowa City, IA (United States); Lie, Stein Atle [Uni Health, Uni Research, Bergen (Norway)

    2012-07-15

    To report on intra-observer, inter-observer, and inter-method reliability and agreement for radiological measurements used in the diagnosis of hip dysplasia at skeletal maturity, as obtained by a manual and a digital measurement technique. Pelvic radiographs from 95 participants (56 females) in a follow-up hip study of 18- to 19-year-old patients were included. Eleven radiological measurements relevant for hip dysplasia (Sharp's, Wiberg's, and Ogata's angles; acetabular roof angle of Toennis; articulo-trochanteric distance; acetabular depth-width ratio; femoral head extrusion index; maximum teardrop width; and the joint space width in three different locations) were validated. Three observers measured the radiographs using both a digital measurement program and manually in AgfaWeb1000. Inter-method and inter- and intra-observer agreement were analyzed using the mean differences between the readings/readers, establishing the 95% limits of agreement. We also calculated the minimum detectable change and the intra-class correlation coefficient. Large variations among different radiological measurements were demonstrated. However, the variation was not related to the use of either the manual or digital measurement technique. For measurements with greater absolute values (Sharp's angle, femoral head extrusion index, and acetabular depth-width ratio) the inter- and intra-observer and inter-method agreements were better as compared to measurements with lower absolute values (acetabular roof angle, teardrop and joint space width). The inter- and intra-observer variation differs notably across different radiological measurements relevant for hip dysplasia at skeletal maturity, a fact that should be taken into account in clinical practice. The agreement between the manual and digital methods is good. (orig.)

  18. Reliability, precision, and measurement in the context of data from ability tests, surveys, and assessments

    International Nuclear Information System (INIS)

    Fisher, W P Jr; Elbaum, B; Coulter, A

    2010-01-01

    Reliability coefficients indicate the proportion of total variance attributable to differences among measures separated along a quantitative continuum by a testing, survey, or assessment instrument. Reliability is usually considered to be influenced by both the internal consistency of a data set and the number of items, though textbooks and research papers rarely evaluate the extent to which these factors independently affect the data in question. Probabilistic formulations of the requirements for unidimensional measurement separate consistency from error by modelling individual response processes instead of group-level variation. The utility of this separation is illustrated via analyses of small sets of simulated data, and of subsets of data from a 78-item survey of over 2,500 parents of children with disabilities. Measurement reliability ultimately concerns the structural invariance specified in models requiring sufficient statistics, parameter separation, unidimensionality, and other qualities that historically have made quantification simple, practical, and convenient for end users. The paper concludes with suggestions for a research program aimed at focusing measurement research more on the calibration and wide dissemination of tools applicable to individuals, and less on the statistical study of inter-variable relations in large data sets.

  19. The reliability of measuring pain distribution and location using body pain diagrams in patients with acute whiplash-associated disorders.

    Science.gov (United States)

    Southerst, Danielle; Stupar, Maja; Côté, Pierre; Mior, Silvano; Stern, Paula

    2013-09-01

    The objective of this study was to measure the interexaminer reliability of scoring pain distribution using paper and electronic body pain diagrams in patients with acute whiplash-associated disorder and to assess the intermethod reliability of measuring pain distribution and location using paper and electronic diagrams. We conducted an interexaminer reliability study on 80 participants recruited from a randomized controlled trial on the conservative management of acute grade I/II whiplash-associated disorder. Participants were assessed for inclusion/exclusion criteria by an experienced clinician. As part of the baseline assessment, participants independently completed paper and electronic pain diagrams. Diagrams were scored independently by 2 examiners using the body region method. Interexaminer and intermethod reliability was computed using intraclass correlation coefficients (ICCs) for pain distribution and κ coefficient for pain location. We used Bland-Altman plots to compute limits of agreement. The interexaminer reliability was ICC = 0.925 for paper and ICC = 0.997 for the electronic body pain diagram. The intermethod reliability for measuring pain distribution ranged from ICC = 0.63 to ICC = 0.93. For pain location, the intermethod reliability varied from κ = 0.23 (posterior neck) to κ = 0.90 (right side of the face). We found good to excellent interexaminer reliability for scoring 2 versions of the body pain diagram. Pain distribution and pain location were reliably and consistently measured on body pain diagrams using paper and electronic methods; therefore, clinicians and researchers may choose either medium when using body pain diagrams. Copyright © 2013 National University of Health Sciences. Published by Mosby, Inc. All rights reserved.

  20. Phase Retrieval Techniques In Coordinates Measurement

    International Nuclear Information System (INIS)

    Harizanova, J. I.; Stoykova, E. V.; Sainov, V. C.

    2007-01-01

    A precise pattern projection profilometry for three-dimensional shape measurements with different methods of fringe generation is presented. The application of phase-shifting algorithm along with two-spacing illumination allow for phase retrieval and estimation of relative and absolute coordinates of the tested samples. The following experimental approaches for fringe generation are investigated: interferometric approach based on a classical Michelson interferometer, digital computation with a DMD projection and light modulation by a sinusoidal phase grating. The theoretical background, experimental results as well as comparison of the applied generation methods are analyzed. The obtained outcomes successfully display the applicability of this technique for surface profile measurement. The application of the proposed techniques for remote, non-destructive in-situ inspection of real objects from cultural heritage is discussed

  1. Reliability of Composite Dichotomous Measurements

    Czech Academy of Sciences Publication Activity Database

    Martinková, Patrícia; Zvára, Karel

    2010-01-01

    Roč. 6, č. 2 (2010), s. 103-109 ISSN 1801-5603 R&D Projects: GA MŠk(CZ) 1M06014 Institutional research plan: CEZ:AV0Z10300504 Keywords : reliability * binary data * logistic regression * Cronbach alpha * Rasch model * myocardial perfusion diagnosis Subject RIV: BB - Applied Statistics, Operational Research http://www.ejbi.cz/articles/201012/65/1.html

  2. Sensitivity to mental effort and test-retest reliability of heart rate variability measures in healthy seniors.

    Science.gov (United States)

    Mukherjee, Shalini; Yadav, Rajeev; Yung, Iris; Zajdel, Daniel P; Oken, Barry S

    2011-10-01

    To determine (1) whether heart rate variability (HRV) was a sensitive and reliable measure in mental effort tasks carried out by healthy seniors and (2) whether non-linear approaches to HRV analysis, in addition to traditional time and frequency domain approaches were useful to study such effects. Forty healthy seniors performed two visual working memory tasks requiring different levels of mental effort, while ECG was recorded. They underwent the same tasks and recordings 2 weeks later. Traditional and 13 non-linear indices of HRV including Poincaré, entropy and detrended fluctuation analysis (DFA) were determined. Time domain, especially mean R-R interval (RRI), frequency domain and, among non-linear parameters - Poincaré and DFA were the most reliable indices. Mean RRI, time domain and Poincaré were also the most sensitive to different mental effort task loads and had the largest effect size. Overall, linear measures were the most sensitive and reliable indices to mental effort. In non-linear measures, Poincaré was the most reliable and sensitive, suggesting possible usefulness as an independent marker in cognitive function tasks in healthy seniors. A large number of HRV parameters was both reliable as well as sensitive indices of mental effort, although the simple linear methods were the most sensitive. Copyright © 2011 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.

  3. Measurement of transplanted pancreatic volume using computed tomography: reliability by intra- and inter-observer variability

    International Nuclear Information System (INIS)

    Lundqvist, Eva; Segelsjoe, Monica; Magnusson, Anders; Andersson, Anna; Biglarnia, Ali-Reza

    2012-01-01

    Background Unlike other solid organ transplants, pancreas allografts can undergo a substantial decrease in baseline volume after transplantation. This phenomenon has not been well characterized, as there are insufficient data on reliable and reproducible volume assessments. We hypothesized that characterization of pancreatic volume by means of computed tomography (CT) could be a useful method for clinical follow-up in pancreas transplant patients. Purpose To evaluate the feasibility and reliability of pancreatic volume assessment using CT scan in transplanted patients. Material and Methods CT examinations were performed on 21 consecutive patients undergoing pancreas transplantation. Volume measurements were carried out by two observers tracing the pancreatic contours in all slices. The observers performed the measurements twice for each patient. Differences in volume measurement were used to evaluate intra- and inter-observer variability. Results The intra-observer variability for the pancreatic volume measurements of Observers 1 and 2 was found to be in almost perfect agreement, with an intraclass correlation coefficient (ICC) of 0.90 (0.77-0.96) and 0.99 (0.98-1.0), respectively. Regarding inter-observer validity, the ICCs for the first and second measurements were 0.90 (range, 0.77-0.96) and 0.95 (range, 0.85-0.98), respectively. Conclusion CT volumetry is a reliable and reproducible method for measurement of transplanted pancreatic volume

  4. Measurement of transplanted pancreatic volume using computed tomography: reliability by intra- and inter-observer variability

    Energy Technology Data Exchange (ETDEWEB)

    Lundqvist, Eva; Segelsjoe, Monica; Magnusson, Anders [Uppsala Univ., Dept. of Radiology, Oncology and Radiation Science, Section of Radiology, Uppsala (Sweden)], E-mail: eva.lundqvist.8954@student.uu.se; Andersson, Anna; Biglarnia, Ali-Reza [Dept. of Surgical Sciences, Section of Transplantation Surgery, Uppsala Univ. Hospital, Uppsala (Sweden)

    2012-11-15

    Background Unlike other solid organ transplants, pancreas allografts can undergo a substantial decrease in baseline volume after transplantation. This phenomenon has not been well characterized, as there are insufficient data on reliable and reproducible volume assessments. We hypothesized that characterization of pancreatic volume by means of computed tomography (CT) could be a useful method for clinical follow-up in pancreas transplant patients. Purpose To evaluate the feasibility and reliability of pancreatic volume assessment using CT scan in transplanted patients. Material and Methods CT examinations were performed on 21 consecutive patients undergoing pancreas transplantation. Volume measurements were carried out by two observers tracing the pancreatic contours in all slices. The observers performed the measurements twice for each patient. Differences in volume measurement were used to evaluate intra- and inter-observer variability. Results The intra-observer variability for the pancreatic volume measurements of Observers 1 and 2 was found to be in almost perfect agreement, with an intraclass correlation coefficient (ICC) of 0.90 (0.77-0.96) and 0.99 (0.98-1.0), respectively. Regarding inter-observer validity, the ICCs for the first and second measurements were 0.90 (range, 0.77-0.96) and 0.95 (range, 0.85-0.98), respectively. Conclusion CT volumetry is a reliable and reproducible method for measurement of transplanted pancreatic volume.

  5. Evaluation of ECT reliability for axial ODSCC in steam generator tubes

    International Nuclear Information System (INIS)

    Lee, Jae Bong; Park, Jai Hak; Kim, Hong Deok; Chung, Han Sub

    2010-01-01

    The integrity of steam generator tubes is usually evaluated based on eddy current test (ECT) results. Because detection capacity of the ECT is not perfect, all of the physical flaws, which actually exist in steam generator tubes, cannot be detected by ECT inspection. Therefore it is very important to analyze ECT reliability in the integrity assessment of steam generators. The reliability of an ECT inspection system is divided into reliability of inspection technique and reliability of quality of analyst. And the reliability of ECT results is also divided into reliability of size and reliability of detection. The reliability of ECT sizing is often characterized as a linear regression model relating true flaw size data to measured flaw size data. The reliability of detection is characterized in terms of probability of detection (POD), which is expressed as a function of flaw size. In this paper the reliability of an ECT inspection system is analyzed quantitatively. POD of the ECT inspection system for axial outside diameter stress corrosion cracks (ODSCC) in steam generator tubes is evaluated. Using a log-logistic regression model, POD is evaluated from hit (detection) and miss (no detection) binary data obtained from destructive and non-destructive inspections of cracked tubes. Crack length and crack depth are considered as variables in multivariate log-logistic regression and their effects on detection capacity are assessed using two-dimensional POD (2-D POD) surface. The reliability of detection is also analyzed using POD for inspection technique (POD T ) and POD for analyst (POD A ).

  6. Measurement techniques for AGR circulators in a full-density rig

    International Nuclear Information System (INIS)

    Watson, I.; Wilson, R.R.

    1977-01-01

    Safety and reliability are the most important factors of a nuclear power plant. This applies in particular to the circulators used to drive the high-density CO 2 around the reactor core and boiler circuits. Under operating conditions, very high sound-pressure levels are generated which could excite components and cause possible fatigue failures. Failures of this type were experienced on the original axial blowers for the Hinkley 'A' Magnox reactor and, following this, a stringent test plan was specified for the AGR circulators. The present paper describes some of the techniques used to measure strain, sound and vibration on circulators in a full-density rig. This rig reproduces the actual reactor working conditions of 300 0 C and 4.1 MN m -2 with gas velocities up to 120 m s -1 . Under these conditions sound-pressure levels of up to 172 dB are generated. This programme of circulator testing has continued for the past 10 years. During this period many obstacles and difficulties were encountered. Some of these problems, together with the solutions found, are discussed. (author)

  7. Reliability of three-dimensional sonographic measurements in early pregnancy using virtual reality

    NARCIS (Netherlands)

    C.M. Verwoerd-Dikkeboom (Christine); A.H.J. Koning (Anton); W.C.J. Hop (Wim); M. Rousian (Melek); P.J. van der Spek (Peter); N. Exalto (Niek); R.P.M. Steegers-Theunissen (Régine)

    2008-01-01

    textabstractObjective: To establish the reliability of three-dimensional (3D) ultrasound measurements in early pregnancy using a virtual reality system (the Barco I-Space). Methods: The study included 28 pregnancies with gestational ages ranging from 6 to 14 (median, 10) weeks. 3D volumes were

  8. Accuracy and reliability of three-dimensional surface reconstruction measurement

    International Nuclear Information System (INIS)

    Mizukami, Chikashi; Yamamoto, Etsuo; Ohmura, Masaki; Oiki, Hiroyuki; Tsuji, Jun; Muneta, Yuki; Tanabe, Makito; Hakuba, Nobuhiro; Azemoto, Syougo.

    1993-01-01

    We are using a new three-dimensional (3-D) surface reconstruction system to measure the temporal bones. This system offers the advantage of observation of the external aperture of the vestibular aqueduct and the porus acusticus internus in living subjects. However, its accuracy has not been confirmed. To investigate the accuracy of this new system, we measured the length of an in situ ceramic ossicular replacement prosthesis (CORP) of known length of 6.0 mm using 3-D surface reconstruction, conventional plain X-ray and polytomography. The CORP was scanned in the axial, sagittal and oblique directions. The mean measured length obtained with the 3-D surface reconstruction images was 5.94±0.21 on vertical scans, 5.91±0.27 on horizontal scans, and 6.01±0.25 on oblique scans. There were no significant differences among the measured lengths obtained in the three directions. Therefore, this 3-D surface reconstruction measurement system is considered to be reliable. Conversely, the mean measured length obtained by plain X-ray was 7.98±0.20, and by polytomography it was 7.94±0.23. These conventional methods have the inherent disadvantage of magnification of size which consequently requires correction. (author)

  9. Reliable four-point flexion test and model for die-to-wafer direct bonding

    Energy Technology Data Exchange (ETDEWEB)

    Tabata, T., E-mail: toshiyuki.tabata@cea.fr; Sanchez, L.; Fournel, F.; Moriceau, H. [Univ. Grenoble Alpes, F-38000 Grenoble, France and CEA, LETI, MINATEC Campus, F-38054 Grenoble (France)

    2015-07-07

    For many years, wafer-to-wafer (W2W) direct bonding has been very developed particularly in terms of bonding energy measurement and bonding mechanism comprehension. Nowadays, die-to-wafer (D2W) direct bonding has gained significant attention, for instance, in photonics and microelectro-mechanics, which supposes controlled and reliable fabrication processes. So, whatever the stuck materials may be, it is not obvious whether bonded D2W structures have the same bonding strength as bonded W2W ones, because of possible edge effects of dies. For that reason, it has been strongly required to develop a bonding energy measurement technique which is suitable for D2W structures. In this paper, both D2W- and W2W-type standard SiO{sub 2}-to-SiO{sub 2} direct bonding samples are fabricated from the same full-wafer bonding. Modifications of the four-point flexion test (4PT) technique and applications for measuring D2W direct bonding energies are reported. Thus, the comparison between the modified 4PT and the double-cantilever beam techniques is drawn, also considering possible impacts of the conditions of measures such as the water stress corrosion at the debonding interface and the friction error at the loading contact points. Finally, reliability of a modified technique and a new model established for measuring D2W direct bonding energies is demonstrated.

  10. NDE reliability and advanced NDE technology validation

    International Nuclear Information System (INIS)

    Doctor, S.R.; Deffenbaugh, J.D.; Good, M.S.; Green, E.R.; Heasler, P.G.; Hutton, P.H.; Reid, L.D.; Simonen, F.A.; Spanner, J.C.; Vo, T.V.

    1989-01-01

    This paper reports on progress for three programs: (1) evaluation and improvement in nondestructive examination reliability for inservice inspection of light water reactors (LWR) (NDE Reliability Program), (2) field validation acceptance, and training for advanced NDE technology, and (3) evaluation of computer-based NDE techniques and regional support of inspection activities. The NDE Reliability Program objectives are to quantify the reliability of inservice inspection techniques for LWR primary system components through independent research and establish means for obtaining improvements in the reliability of inservice inspections. The areas of significant progress will be described concerning ASME Code activities, re-analysis of the PISC-II data, the equipment interaction matrix study, new inspection criteria, and PISC-III. The objectives of the second program are to develop field procedures for the AE and SAFT-UT techniques, perform field validation testing of these techniques, provide training in the techniques for NRC headquarters and regional staff, and work with the ASME Code for the use of these advanced technologies. The final program's objective is to evaluate the reliability and accuracy of interpretation of results from computer-based ultrasonic inservice inspection systems, and to develop guidelines for NRC staff to monitor and evaluate the effectiveness of inservice inspections conducted on nuclear power reactors. This program started in the last quarter of FY89, and the extent of the program was to prepare a work plan for presentation to and approval from a technical advisory group of NRC staff

  11. Spherical near-field antenna measurements — The most accurate antenna measurement technique

    DEFF Research Database (Denmark)

    Breinbjerg, Olav

    2016-01-01

    The spherical near-field antenna measurement technique combines several advantages and generally constitutes the most accurate technique for experimental characterization of radiation from antennas. This paper/presentation discusses these advantages, briefly reviews the early history and present...

  12. [Cholinesterases in total blood measured with a semiquantitative technique, and plasma or erythrocyte cholinesterases measured with quantitative techniques].

    Science.gov (United States)

    Carmona-Fonseca, Jaime

    2007-06-01

    An equivalence model which allows comparison of blood cholinesterase values, measured by Lovibond (semiquantitative technique), and Michel, EQM, Monotest (erythrocyte and plasma cholinesterases) values measured by quantitative techniques is required. The performance of Lovibond (Edson tintometric and Limperos & Ranta techniques) were compared with quantitative techniques. The experimental design was descriptive, cross-sectional, and prospective. From a working population (18-59 years) in Valle de Aburrá and Near East of Antioquia. 827 representative samples were chosen for their lack of exposure to cholinesterase-inhibiting plaguicides and affiliated to the Social Security System. (1) 827 workers were classified by Lovibond in four categories: 821 values with 75% of cholinesterase activity or greater (categories 75, 87.5 and 100%) and 6 with cholinesterase activity smaller than 75%. (2) With each quantitative method, the mean values of erythrocyte and plasmatic cholinesterase corresponding to the four values obtained with Lovibond were statistically different to each other. (3) The mean values of each quantitative technique increased when increased the tintometric method value. (4) Lovibond classified the low enzymatic erythrocyte activity very poorly (61-73%), but the classification of the low enzymatic plasma activity was almost completely in error (94-96%). The values of erythrocyte or plasma cholinesterase were adequately estimated by both the quantitative techniques of Michel and EQM and by Lovibond, but only when the enzymatic activity is normal. Lovibond, however, had a poor capacity to designate as "low" the values that were low according to the quantitative tests.

  13. Intrarater reliability of hand held dynamometry in measuring lower extremity isometric strength using a portable stabilization device.

    Science.gov (United States)

    Jackson, Steven M; Cheng, M Samuel; Smith, A Russell; Kolber, Morey J

    2017-02-01

    Hand held dynamometry (HHD) is a more objective way to quantify muscle force production (MP) compared to traditional manual muscle testing. HHD reliability can be negatively impacted by both the strength of the tester and the subject particularly in the lower extremities due to larger muscle groups. The primary aim of this investigation was to assess intrarater reliability of HHD with use of a portable stabilization device for lower extremity MP in an athletic population. Isometric lower extremity strength was measured for bilateral lower extremities including hip abductors, external rotators, adductors, knee extensors, and ankle plantar flexors was measured in a sample of healthy recreational runners (8 male, 7 females, = 30 limbs) training for a marathon. These measurements were assessed using an intrasession intrarater reliability design. Intraclass correlation coefficients (ICC) were calculated using 3,1 model based on the single rater design. The standard error of measurement (SEM) for each muscle group was also calculated. ICC were excellent ranging from ICC (3,1) = 0.93-0.98 with standard error of measurements ranging from 0.58 to 17.2 N. This study establishes the use of a HHD with a portable stabilization device as demonstrating good reliability within testers for measuring lower extremity muscle performance in an active healthy population. Copyright © 2016 Elsevier Ltd. All rights reserved.

  14. Optical techniques for in-core measurements

    International Nuclear Information System (INIS)

    Brichard, B.

    2007-01-01

    The in-situ measurement of dimensional changes is a key issue for advanced irradiation programs in Material Test Reactors. It is for example crucial to monitor the changes of the dimensions of nuclear fuel assemblies as well as those of mechanically stressed structural material samples during in-pile irradiations. Different techniques already exist to carry out such measurements but they all come with a number of drawbacks. SCK-CEN and CEA have therefore decided to share the development of a measurement system that was never applied before in the core of a nuclear reactor. It relies on optical dimensional measurements and brings along unprecedented non-intrusiveness combined with high resolution. A clear advantage in using compact optical sensors results in a more efficient occupation of the irradiation volume available for target testings as well as a significant reduction of the gamma-heating associated with the in-pile instrumentation. The objectives of these shared studies are to design, develop, test and qualify an in-pile dimensional measurement system based on optical techniques, with the goal to implement this system in future MTR irradiation experiments. In 2006, we focussed our activities on sensor analysis, selection of the sensor prototypes, procurement and first irradiation experiment

  15. The reliability of the Extra Load Index as a measure of relative load carriage economy.

    Science.gov (United States)

    Hudson, Sean; Cooke, Carlton; Lloyd, Ray

    2017-09-01

    The aim of this study was to measure the reliability of the extra load index (ELI) as a method for assessing relative load carriage economy. Seventeen volunteers (12 males, 5 females) performed walking trials at 3 km·h -1 , 6 km·h -1 and a self-selected speed. Trial conditions were repeated 7 days later to assess test-retest reliability. Trials involved four 4-minute periods of walking, each separated by 5 min of rest. The initial stage was performed unloaded followed in a randomised order by a second unloaded period and walking with backpacks of 7 and 20 kg. Results show ELI values did not differ significantly between trials for any of the speeds (p = 0.46) with either of the additional loads (p = 0.297). The systematic bias, limits of agreement and coefficients of variation were small in all trial conditions. We conclude the ELI appears to be a reliable measure of relative load carriage economy. Practitioner Summary: This paper demonstrates that the ELI is a reliable measure of load carriage economy at a range of walking speeds with both a light and heavy load. The ELI, therefore, represents a useful tool for comparing the relative economy associated with different load carriage systems.

  16. Cognitive environment simulation: An artificial intelligence system for human performance assessment: Cognitive reliability analysis technique: [Technical report, May 1986-June 1987

    International Nuclear Information System (INIS)

    Woods, D.D.; Roth, E.M.

    1987-11-01

    This report documents the results of Phase II of a three phase research program to develop and validate improved methods to model the cognitive behavior of nuclear power plant (NPP) personnel. In Phase II a dynamic simulation capability for modeling how people form intentions to act in NPP emergency situations was developed based on techniques from artificial intelligence. This modeling tool, Cognitive Environment Simulation or CES, simulates the cognitive processes that determine situation assessment and intention formation. It can be used to investigate analytically what situations and factors lead to intention failures, what actions follow from intention failures (e.g., errors of omission, errors of commission, common mode errors), the ability to recover from errors or additional machine failures, and the effects of changes in the NPP person-machine system. The Cognitive Reliability Assessment Technique (or CREATE) was also developed in Phase II to specify how CES can be used to enhance the measurement of the human contribution to risk in probabilistic risk assessment (PRA) studies. 34 refs., 7 figs., 1 tab

  17. Reliability and validity of the test of incremental respiratory endurance measures of inspiratory muscle performance in COPD

    Directory of Open Access Journals (Sweden)

    Formiga MF

    2018-05-01

    Full Text Available Magno F Formiga,1,2 Kathryn E Roach,1 Isabel Vital,3 Gisel Urdaneta,3 Kira Balestrini,3 Rafael A Calderon-Candelario,3,4 Michael A Campos,3,4,* Lawrence P Cahalin1,* 1Department of Physical Therapy, University of Miami Miller School of Medicine, Coral Gables, FL, USA; 2CAPES Foundation, Ministry of Education of Brazil, Brasilia, Brazil; 3Pulmonary Section, Miami Veterans Administration Medical Center, Miami, FL, USA; 4Division of Pulmonary, Allergy, Critical Care and Sleep Medicine, University of Miami Miller School of Medicine, Miami, FL, USA *These authors contributed equally to this work Purpose: The Test of Incremental Respiratory Endurance (TIRE provides a comprehensive assessment of inspiratory muscle performance by measuring maximal inspiratory pressure (MIP over time. The integration of MIP over inspiratory duration (ID provides the sustained maximal inspiratory pressure (SMIP. Evidence on the reliability and validity of these measurements in COPD is not currently available. Therefore, we assessed the reliability, responsiveness and construct validity of the TIRE measures of inspiratory muscle performance in subjects with COPD. Patients and methods: Test–retest reliability, known-groups and convergent validity assessments were implemented simultaneously in 81 male subjects with mild to very severe COPD. TIRE measures were obtained using the portable PrO2 device, following standard guidelines. Results: All TIRE measures were found to be highly reliable, with SMIP demonstrating the strongest test–retest reliability with a nearly perfect intraclass correlation coefficient (ICC of 0.99, while MIP and ID clustered closely together behind SMIP with ICC values of about 0.97. Our findings also demonstrated known-groups validity of all TIRE measures, with SMIP and ID yielding larger effect sizes when compared to MIP in distinguishing between subjects of different COPD status. Finally, our analyses confirmed convergent validity for both SMIP

  18. Ultra-low power photoplethysmograhy SpO2 measuring techniques

    Energy Technology Data Exchange (ETDEWEB)

    Barriuso Medrano, C.; Calpe Maravilla, J.; Millan Navarro, C.

    2016-07-01

    Photoplethysmograph(y (PPG) is widely used to obtain vital signs such as the peripheral capillary oxygen saturation or the heart rate (HR) non-invasively in real time. These techniques require a great amount of power in order to obtain reliable data, and its use is limited to mains powered devices. For this reason it is of great importance to find methods and algorithms that reduce its current consumption. Three techniques to optimize current consumption when obtaining PPG signals are proposed in this study. Each of them takes advantage of the fact that to obtain these vital signs we only need the peaks of the PPG signal, which means that we may change the accuracy of the acquisition depending on the position within the pulse. The current consumption can be reduced by 55% in the sensor and 62% in the microcontroller. (Author)

  19. A novel technique for partial discharge measurement

    International Nuclear Information System (INIS)

    Farrokh, Fattahi; Navid, Tagizadegan; Ahmad, Zentabchi; Mehdi, Rashidi

    2005-01-01

    Full text : Partial discharges are a sensitive measure of local electrical stress and therefore the measurements is very often used as a quality check of the insulation. The inception of partial discharges gives information on the limit of the electrical strength of the insulating material before a complete discharge between the conductors takes place. Therefore the insulating material can be tested with high stress but without damaging or reducing the performance of the insulation. Also, for partial discharge measurements it should be taken into account that every stress of the insulation will have an influence on the life expectancy of the material, but a reasonable compromise between the stress during the measurement in order to get reliable results and the influence of he lifetime should be found and established in the relevant standard for the particular equipment, for example transformers, cables and so on

  20. Two-phase flow measurement by pulsed neutron activation techniques

    International Nuclear Information System (INIS)

    Kehler, P.

    1978-01-01

    The Pulsed Neutron Activation (PNA) technique for measuring the mass flow velocity and the average density of two-phase mixtures is described. PNA equipment can be easily installed at different loops, and PNA techniques are non-intrusive and independent of flow regimes. These features of the PNA technique make it suitable for in-situ measurement of two-phase flows, and for calibration of more conventional two-phase flow measurement devices. Analytic relations governing the various PNA methods are derived. The equipment and procedures used in the first air-water flow measurement by PNA techniques are discussed, and recommendations are made for improvement of future tests. In the present test, the mass flow velocity was determined with an accuracy of 2 percent, and average densities were measured down to 0.08 g/cm 3 with an accuracy of 0.04 g/cm 3 . Both the accuracy of the mass flow velocity measurement and the lower limit of the density measurement are functions of the injected activity and of the total number of counts. By using a stronger neutron source and a larger number of detectors, the measurable density can be decreased by a factor of 12 to .007 g/cm 3 for 12.5 cm pipes, and to even lower ranges for larger pipes

  1. National and Regional Surveys of Radon Concentration in Dwellings. Review of Methodology and Measurement Techniques

    International Nuclear Information System (INIS)

    2013-01-01

    Reliable, comparable and 'fit for purpose' results are essential requirements for any decision based on analytical measurements. For the analyst, the availability of tested and validated sampling and analytical procedures is an extremely important tool for carrying out such measurements. For maximum utility, such procedures should be comprehensive, clearly formulated and readily available to both the analyst and the customer for reference. In the specific case of radon surveys, it is very important to design a survey in such a way as to obtain results that can reasonably be considered representative of a population. Since 2004, the Environment Programme of the IAEA has included activities aimed at the development of a set of procedures for the measurement of radionuclides in terrestrial environmental samples. The development of radon measurement procedures for national and regional surveys started with the collection and review of more than 160 relevant scientific papers. On the basis of this review, this publication summarizes the methodology and the measurement techniques suitable for a population representative national or regional survey on radon concentration in the indoor air of dwellings. The main elements of the survey design are described and discussed, such as the sampling scheme, the protocols, the questionnaire and the data analysis, with particular attention to the potential biases that can affect the representativeness of the results. Moreover, the main measurement techniques suitable for national surveys on indoor radon are reviewed, with particular attention to the elements that can affect the precision and accuracy of the results

  2. National and Regional Surveys of Radon Concentration in Dwellings. Review of Methodology and Measurement Techniques

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2013-12-15

    Reliable, comparable and 'fit for purpose' results are essential requirements for any decision based on analytical measurements. For the analyst, the availability of tested and validated sampling and analytical procedures is an extremely important tool for carrying out such measurements. For maximum utility, such procedures should be comprehensive, clearly formulated and readily available to both the analyst and the customer for reference. In the specific case of radon surveys, it is very important to design a survey in such a way as to obtain results that can reasonably be considered representative of a population. Since 2004, the Environment Programme of the IAEA has included activities aimed at the development of a set of procedures for the measurement of radionuclides in terrestrial environmental samples. The development of radon measurement procedures for national and regional surveys started with the collection and review of more than 160 relevant scientific papers. On the basis of this review, this publication summarizes the methodology and the measurement techniques suitable for a population representative national or regional survey on radon concentration in the indoor air of dwellings. The main elements of the survey design are described and discussed, such as the sampling scheme, the protocols, the questionnaire and the data analysis, with particular attention to the potential biases that can affect the representativeness of the results. Moreover, the main measurement techniques suitable for national surveys on indoor radon are reviewed, with particular attention to the elements that can affect the precision and accuracy of the results.

  3. power system reliability in supplying nuclear reactors

    International Nuclear Information System (INIS)

    Gad, M.M.M.

    2007-01-01

    this thesis presents a simple technique for deducing minimal cut set (MCS) from the defined minimal path set (MPS) of generic distribution system and this technique have been used to evaluate the basic reliability indices of Egypt's second research reactor (ETRR-2) electrical distribution network. the alternative system configurations are then studied to evaluate their impact on service reliability. the proposed MCS approach considers both sustained and temporary outage. the temporary outage constitutes an important parameter in characterizing the system reliability indices for critical load point in distribution system. it is also consider the power quality impact on the reliability indices

  4. Validity and intra-rater reliability of an android phone application to measure cervical range-of-motion.

    Science.gov (United States)

    Quek, June; Brauer, Sandra G; Treleaven, Julia; Pua, Yong-Hao; Mentiplay, Benjamin; Clark, Ross Allan

    2014-04-17

    Concurrent validity and intra-rater reliability using a customized Android phone application to measure cervical-spine range-of-motion (ROM) has not been previously validated against a gold-standard three-dimensional motion analysis (3DMA) system. Twenty-one healthy individuals (age:31 ± 9.1 years, male:11) participated, with 16 re-examined for intra-rater reliability 1-7 days later. An Android phone was fixed on a helmet, which was then securely fastened on the participant's head. Cervical-spine ROM in flexion, extension, lateral flexion and rotation were performed in sitting with concurrent measurements obtained from both a 3DMA system and the phone.The phone demonstrated moderate to excellent (ICC = 0.53-0.98, Spearman ρ = 0.52-0.98) concurrent validity for ROM measurements in cervical flexion, extension, lateral-flexion and rotation. However, cervical rotation demonstrated both proportional and fixed bias. Excellent intra-rater reliability was demonstrated for cervical flexion, extension and lateral flexion (ICC = 0.82-0.90), but poor for right- and left-rotation (ICC = 0.05-0.33) using the phone. Possible reasons for the outcome are that flexion, extension and lateral-flexion measurements are detected by gravity-dependent accelerometers while rotation measurements are detected by the magnetometer which can be adversely affected by surrounding magnetic fields. The results of this study demonstrate that the tested Android phone application is valid and reliable to measure ROM of the cervical-spine in flexion, extension and lateral-flexion but not in rotation likely due to magnetic interference. The clinical implication of this study is that therapists should be mindful of the plane of measurement when using the Android phone to measure ROM of the cervical-spine.

  5. Quality of the Critical Incident Technique in practice: Interrater reliability and users' acceptance under real conditions

    Directory of Open Access Journals (Sweden)

    ANNA KOCH

    2009-03-01

    Full Text Available The Critical Incident Technique (CIT is a widely used task analysis method in personnel psychology. While studies on psychometric properties of the CIT so far primarily took into account relevance ratings of task-lists or attributes, and hence, only a smaller or adapted part of the CIT, little is known about the psychometric properties of the complete CIT in its most meaningful and fruitful way. Therefore, the aim of the present study was to assess interrater reliability and the participants’ view of the CIT under real conditions and especially to provide data for the key step of the CIT: the classification of behavior descriptions into requirements. Additionally, the cost-benefit-ratio and practicability were rated from the participants’ views as an important indicator for the acceptance of the task analysis approach in practice. Instructors of German Institutions for Statutory Accidents Insurance and Prevention as well as their supervisors took part in a job analysis with the CIT. Moderate interrater reliability for the relevance rating was found while the classification step yielded unexpectedly low coefficients for interrater reliability. The cost-benefit-ratio and practicability of the complete CIT were rated very positive. The results are discussed in relation to determinants that facilitate or impede the application of task analysis procedures.

  6. On the Reliability of Implicit and Explicit Memory Measures.

    Science.gov (United States)

    Buchner, Axel; Wippich, Werner

    2000-01-01

    Studied the reliability of implicit and explicit memory tests in experiments involving these tests. Results with 168, 84, 120, and 128 undergraduates show that methodological artifacts may cause implicit memory tests to have lower reliability than explicit memory tests, but that implicit tests need not necessarily be less reliable. (SLD)

  7. Reliability of the Danish version of the McGill ingestive skills assessment for observation-based measures during meals

    DEFF Research Database (Denmark)

    Hansen, Tina; Lambert, Heather C; Faber, Jens

    2012-01-01

    To establish measurement equivalence in terms of reliability of the Danish version of the Canadian McGill ingestive skills assessment (MISA) for use by occupational therapists.......To establish measurement equivalence in terms of reliability of the Danish version of the Canadian McGill ingestive skills assessment (MISA) for use by occupational therapists....

  8. Test-retest reliability of handgrip strength measurement using a hydraulic hand dynamometer in patients with cervical radiculopathy.

    Science.gov (United States)

    Savva, Christos; Giakas, Giannis; Efstathiou, Michalis; Karagiannis, Christos

    2014-01-01

    The purpose of this study was to evaluate the test-retest reliability of handgrip strength measurement using a hydraulic hand dynamometer in patients with cervical radiculopathy (CR). A convenience sample of 19 participants (14 men and 5 women; mean ± SD age, 50.5 ± 12 years) with CR was measured using a Jamar hydraulic hand dynamometer by the same rater on 2 different testing sessions with an interval of 7 days between sessions. Data collection procedures followed standardized grip strength testing guidelines established by the American Society of Hand Therapists. During the repeated measures, patients were advised to rest their upper limb in the standardized arm position and encouraged to exert 3 maximum gripping efforts. The mean value of the 3 efforts (measured in kilogram force [Kgf]) was used for data analysis. The intraclass correlation coefficient, SEM, and the Bland-Altman plot were used to estimate test-retest reliability and measurement precision. Grip strength measurement in CR demonstrated an intraclass correlation coefficient of 0.976, suggesting excellent test-retest reliability. The small SEM in both testing sessions (SEM1, 2.41 Kgf; SEM2, 2.51 Kgf) as well as the narrow width of the 95% limits of agreements (95% limits of agreement, -4.9 to 4.4 Kgf) in the Bland-Altman plot reflected precise measurements of grip strength in both occasions. Excellent test-retest reliability for grip strength measurement was measured in patients with CR, demonstrating that a hydraulic hand dynamometer could be used as an outcome measure for these patients. Copyright © 2014 National University of Health Sciences. Published by Mosby, Inc. All rights reserved.

  9. Thermal cycling fatigue of organic thermal interface materials using a thermal-displacement measurement technique

    Science.gov (United States)

    Steill, Jason Scott

    The long term reliability of polymer-based thermal interface materials (TIM) is essential for modern electronic packages which require robust thermal management. The challenge for today's materials scientists and engineers is to maximize the heat flow from integrated circuits through a TIM and out the heat sink. Thermal cycling of the electronic package and non-uniformity in the heat flux with respect to the plan area can lead to void formation and delamination which re-introduces inefficient heat transfer. Measurement and understanding at the nano-scale is essential for TIM development. Finding and documenting the evolution of the defects is dependent upon a full understanding of the thermal probes response to changing environmental conditions and the effects of probe usage. The response of the thermal-displacement measurement technique was dominated by changes to the environment. Accurate measurement of the thermal performance was hindered by the inability to create a model system and control the operating conditions. This research highlights the need for continued study into the probe's thermal and mechanical response using tightly controlled test conditions.

  10. Accuracy and reliability of facial soft tissue depth measurements using cone beam computer tomography

    NARCIS (Netherlands)

    Fourie, Zacharias; Damstra, Janalt; Gerrits, Pieter; Ren, Yijin

    2010-01-01

    It is important to have accurate and reliable measurements of soft tissue thickness for specific landmarks of the face and scalp when producing a facial reconstruction. In the past several methods have been created to measure facial soft tissue thickness (FSTT) in cadavers and in the living. The

  11. Establishing the Appropriate Attributes in Current Human Reliability Assessment Techniques for Nuclear Safety

    International Nuclear Information System (INIS)

    Bowie, Jane; Munley, Gary; Dang, Vinh; Wreathall, John; Bye, Andreas; Cooper, Susan; Marble, Julie; Peters, Sean; Xing, Jing; Fauchille, Veronique; Fiset, Jean Yves; Haage, Monica; Johanson, Gunnar; Jung, Won Dae; Kim, Jaewhan; Lee, Seung Jung; Kubicek, Jan; Le Bot, Pierre; Pesme, Helene; Preischl, Wolfgang; Salway, Alice; Amri, Abdallah; Lamarre, Greg; White, Andrew; )

    2015-03-01

    This report presents the results of a joint task of the Working Groups on Risk Assessment (WGRISK) and on Human and Organisational Factors (WGHOF) of the OECD/NEA CSNI, to identify desirable attributes of Human Reliability Assessment (HRA) methods, and to evaluate a range of HRA methods used in OECD member countries against those attributes. The purpose of this project is to provide information that will support regulators and operators of nuclear facilities when making judgements about the appropriateness of HRA methods for conducting assessments in support of Probabilistic Safety Assessments (PSA). The task was performed by an international team of Human Factors, HRA and PSA experts from a broad range of OECD member countries. As in other reviews of HRA methods, the study did not set out to recommend or promote the use of any particular HRA method. Rather the study aims to identify the strengths and limitations of commonly used and developing methods to aid those responsible for production of HRAs in selecting appropriate tools for specific HRA applications. The study also aims to assist regulators when making judgements on the appropriateness of the application of an HRA technique within nuclear-related probabilistic safety assessments. The report is aimed at practitioners in the field of human reliability assessment, human factors, and risk assessment more generally

  12. NASA reliability preferred practices for design and test

    Science.gov (United States)

    1991-01-01

    Given here is a manual that was produced to communicate within the aerospace community design practices that have contributed to NASA mission success. The information represents the best technical advice that NASA has to offer on reliability design and test practices. Topics covered include reliability practices, including design criteria, test procedures, and analytical techniques that have been applied to previous space flight programs; and reliability guidelines, including techniques currently applied to space flight projects, where sufficient information exists to certify that the technique will contribute to mission success.

  13. Reliability and reproducibility of disc-foveal angle measurements by non-mydriatic fundus photography.

    Science.gov (United States)

    Le Jeune, Caroline; Chebli, Fayçal; Leon, Lorette; Anthoine, Emmanuelle; Weber, Michel; Péchereau, Alain; Lebranchu, Pierre

    2018-01-01

    Abnormal torsion could be associated with cyclovertical strabismus, but torsion measurements are not reliable in children. To assess an objective fundus torsion evaluation in a paediatric population, we used Non-Mydriatic Fundus photography (NMFP) in healthy and cyclovertical strabismus patients to evaluate the disc-foveal angle over time and observers. We used a retrospective set of NMFP including 24 A or V-pattern strabismus and 27 age-matched normal children (mean age 6.4 and 6.7 years respectively), taken during 2 distinct follow-up consultations (separated by 251 and 479 days respectively). Each disc-foveal angle measurement (from which the ocular torsion can be assessed) was performed by 5 different observers, using graphical software and based on reproducible fundus anatomical marks. Statistical analysis was performed with a multivariate ANOVA using group, time and observers as factors, in addition to intraclass coefficient correlation (ICC) to assess measurement reproducibility. A significant difference of disc-foveal angle measures was observed between groups (p0,97). Abnormal amount of objective torsion could be associated with alphabet-pattern strabismus. Disc-foveal angle evaluation by NMFP in a children population appears as a non-invasive, reliable and reproducible method.

  14. 14CO2 labeling: a reliable technique for rapid measurement of total root exudation capacity and vascular sap flow in crops

    International Nuclear Information System (INIS)

    Singh, Bhupinder; Ahuja, Sumedha; Pandey, Renu; Singhal, R.K.

    2014-01-01

    Ability of roots to release organic compounds in its rhizosphere is known to improve plant available nutrients and reduces heavy metal toxicity by immobilization. It is regarded as an important determinant of micro nutrient deficiency tolerance in plants. Uptake of nutrients and translocation of photoassimilates, on the other hand are governed by the strength of the transpiration stream and sink demand respectively. Measurement of vascular sap flow, thus, is critical for understanding of the translocation efficiency and consequently the sink demand that keeps changing during the crop growth cycle. Measurement of the root exudation capacity and the vascular sap flow is cumbersome and time consuming. Since, the exudates released by the roots and the photosynthates translocated between the source and the sink are essentially carbon compounds, use of labeled carbon as tag could potentially be exploited for a rapid and reliable measurement of exudation and vascular sap flow in crop plants. We report here the experimental results involving 14 C labeling of groundnut, a legume crop, as 14 CO 2 generated by acidification of sodium bicarbonate. An additional factor of seed gamma irradiation was used to generate variability in the root exudation and the sap flow. The 14 C release by the roots was compared against the 14 C transport in the vascular sap. An experimental hypothesis that a higher 14 C level in the vascular sap would indicate a higher root release of carbon by the roots into the rhizosphere was verified. (author)

  15. Human reliability assessment and probabilistic risk assessment

    International Nuclear Information System (INIS)

    Embrey, D.E.; Lucas, D.A.

    1989-01-01

    Human reliability assessment (HRA) is used within Probabilistic Risk Assessment (PRA) to identify the human errors (both omission and commission) which have a significant effect on the overall safety of the system and to quantify the probability of their occurrence. There exist a variey of HRA techniques and the selection of an appropriate one is often difficult. This paper reviews a number of available HRA techniques and discusses their strengths and weaknesses. The techniques reviewed include: decompositional methods, time-reliability curves and systematic expert judgement techniques. (orig.)

  16. Inter-rater reliability of measures to characterize the tobacco retail environment in Mexico

    Directory of Open Access Journals (Sweden)

    Marissa G Hall

    2015-11-01

    Full Text Available Objective. To evaluate the inter-rater reliability of a data collection instrument to assess the tobacco retail environ- ment in Mexico, after major marketing regulations were implemented. Materials and methods. In 2013, two data collectors independently evaluated 21 stores in two census tracts, through a data collection instrument that assessed the presence of price promotions, whether single cigarettes were sold, the number of visible advertisements, the pre- sence of signage prohibiting the sale of cigarettes to minors, and characteristics of cigarette pack displays. We evaluated the inter-rater reliability of the collected data, through the calculation of metrics such as intraclass correlation coefficient, percent agreement, Cohen’s kappa and Krippendorff’s alpha. Results. Most measures demonstrated substantial or perfect inter-rater reliability. Conclusions. Our results indicate the potential utility of the data collection instrument for future point-of-sale research.

  17. Effects of equipment and technique on peak flow measurements

    Directory of Open Access Journals (Sweden)

    O'Driscoll B Ronan

    2006-06-01

    Full Text Available Abstract Background Different lung function equipment and different respiratory manoeuvres may produce different Peak Expiratory Flow (PEF results. Although the PEF is the most common lung function test, there have been few studies of these effects and no previous study has evaluated both factors in a single group of patients. Methods We studied 36 subjects (PEF range 80–570 l/min. All patients recorded PEF measurements using a short rapid expiration following maximal inspiration (PEF technique or a forced maximal expiration to residual volume (FVC technique. Measurements were made using a Wright's peak flow meter, a turbine spirometer and a Fleisch pneumotachograph spirometer. Results The mean PEF was 8.7% higher when the PEF technique was used (compared with FVC technique, p Conclusion Peak flow measurements are affected by the instruction given and by the device and Peak Flow scale used. Patient management decisions should not be based on PEF measurement made on different instruments.

  18. The navicular position test - a reliable measure of the navicular bone position during rest and loading

    DEFF Research Database (Denmark)

    Spörndly-Nees, Søren; Dåsberg, Brian; Nielsen, Rasmus Oestergaard

    2011-01-01

    .08 degrees, ICC = 0.91. Discussion: The present data support The Navicular Position Test as a reliable test of the navicular bone position during rest and loading measured in a simple test set-up. Conclusion: The Navicular Position Test was shown to have a high intraday-, intra- and inter-tester reliability...

  19. Trade-Offs between Energy Saving and Reliability in Low Duty Cycle Wireless Sensor Networks Using a Packet Splitting Forwarding Technique

    Directory of Open Access Journals (Sweden)

    Leonardi Alessandro

    2010-01-01

    Full Text Available One of the challenging topics and design constraints in Wireless Sensor Networks (WSNs is the reduction of energy consumption because, in most application scenarios, replacement of power resources in sensor devices might be unfeasible. In order to minimize the power consumption, some nodes can be put to sleep during idle times and wake up only when needed. Although it seems the best way to limit the consumption of energy, other performance parameters such as network reliability have to be considered. In a recent paper, we introduced a new forwarding algorithm for WSNs based on a simple splitting procedure able to increase the network lifetime. The forwarding technique is based on the Chinese Remainder Theorem and exhibits very good results in terms of energy efficiency and complexity. In this paper, we intend to investigate a trade-off between energy efficiency and reliability of the proposed forwarding scheme when duty-cycling techniques are considered too.

  20. Test-retest reliability of sensor-based sit-to-stand measures in young and older adults.

    Science.gov (United States)

    Regterschot, G Ruben H; Zhang, Wei; Baldus, Heribert; Stevens, Martin; Zijlstra, Wiebren

    2014-01-01

    This study investigated test-retest reliability of sensor-based sit-to-stand (STS) peak power and other STS measures in young and older adults. In addition, test-retest reliability of the sensor method was compared to test-retest reliability of the Timed Up and Go Test (TUGT) and Five-Times-Sit-to-Stand Test (FTSST) in older adults. Ten healthy young female adults (20-23 years) and 31 older adults (21 females; 73-94 years) participated in two assessment sessions separated by 3-8 days. Vertical peak power was assessed during three (young adults) and five (older adults) normal and fast STS trials with a hybrid motion sensor worn on the hip. Older adults also performed the FTSST and TUGT. The average sensor-based STS peak power of the normal STS trials and the average sensor-based STS peak power of the fast STS trials showed excellent test-retest reliability in young adults (intra-class correlation (ICC)≥0.90; zero in 95% confidence interval of mean difference between test and retest (95%CI of D); standard error of measurement (SEM)≤6.7% of mean peak power) and older adults (ICC≥0.91; zero in 95%CI of D; SEM≤9.9%). Test-retest reliability of sensor-based STS peak power and TUGT (ICC=0.98; zero in 95%CI of D; SEM=8.5%) was comparable in older adults, test-retest reliability of the FTSST was lower (ICC=0.73; zero outside 95%CI of D; SEM=14.4%). Sensor-based STS peak power demonstrated excellent test-retest reliability and may therefore be useful for clinical assessment of functional status and fall risk. Copyright © 2014 Elsevier B.V. All rights reserved.

  1. Seminar on Detectors and measurements techniques

    International Nuclear Information System (INIS)

    Holm, E.

    2002-01-01

    A Nordic Seminar on detectors and radionuclide measurement techniques was held in Lund, Sweden, May 3-4, 2001. The objective was to highlight recent progress and problems for techniques to study environmental radioactivity. It covered the aspect of detector sample geometry's and methods for evaluation of gamma gamma pulse height distributions. Within the field of alpha-spectrometric techniques gridded ionisation chambers, semiconductor detectors and a general description for analysis of alpha-particle-spectra were presented. Recent development in mass spectrometric techniques, AMS (Accelerator Mass Spectrometry) and ICPMS (Inductively Coupled Plasma mass Spectrometry) for long-lived radionuclides was described. Principles for analysis of beta particle emitters, especially by liquid scintillation were presented. The seminar also covered radiochemistry such advantages and disadvantages between ion exchange, solvent extraction and extraction chromatography. The use of controlled laboratory conditions for discerning the dynamics of accumulation in organisms was demonstrated. Other techniques such as neutron activation were also shown to be useful analytical tool for certain long-lived radionuclides. The results of the intercalibration exercises within the Nordic countries showed the importance of such analytical quality control. (au)

  2. Generalizability Theory Reliability of Written Expression Curriculum-Based Measurement in Universal Screening

    Science.gov (United States)

    Keller-Margulis, Milena A.; Mercer, Sterett H.; Thomas, Erin L.

    2016-01-01

    The purpose of this study was to examine the reliability of written expression curriculum-based measurement (WE-CBM) in the context of universal screening from a generalizability theory framework. Students in second through fifth grade (n = 145) participated in the study. The sample included 54% female students, 49% White students, 23% African…

  3. Establishing Reliability and Construct Validity for an Instrument to Measure Environmental Connectedness

    Science.gov (United States)

    Beery, Thomas H.

    2013-01-01

    The purpose of this preliminary study is to establish a reliable and valid measure of environmental connectedness (EC) to allow for further exploration of the Swedish Outdoor Recreation in Change national survey data. The Nordic concept of friluftsliv (nature-based outdoor recreation) and the environmental psychology concept of EC are explored to…

  4. The Nutrition Literacy Assessment Instrument is a Valid and Reliable Measure of Nutrition Literacy in Adults with Chronic Disease.

    Science.gov (United States)

    Gibbs, Heather D; Ellerbeck, Edward F; Gajewski, Byron; Zhang, Chuanwu; Sullivan, Debra K

    2018-03-01

    To test the reliability and validity of the Nutrition Literacy Assessment Instrument (NLit) in adult primary care and identify the relationship between nutrition literacy and diet quality. This instrument validation study included a cross-sectional sample participating in up to 2 visits 1 month apart. A total of 429 adults with nutrition-related chronic disease were recruited from clinics and a patient registry affiliated with a Midwestern university medical center. Nutrition literacy was measured by the NLit, which was composed of 6 subscales: nutrition and health, energy sources in food, food label and numeracy, household food measurement, food groups, and consumer skills. Diet quality was measured by Healthy Eating Index-2010 with nutrient data from Diet History Questionnaire II surveys. The researchers measured factor validity and reliability by using binary confirmatory factor analysis; test-retest reliability was measured by Pearson r and the intraclass correlation coefficient, and relationships between nutrition literacy and diet quality were analyzed by linear regression. The NLit demonstrated substantial factor validity and reliability (0.97; confidence interval, 0.96-0.98) and test-retest reliability (0.88; confidence interval, 0.85-0.90). Nutrition literacy was the most significant predictor of diet quality (β = .17; multivariate coefficient = 0.10; P measuring nutrition literacy in adult primary care patients. Copyright © 2017 Society for Nutrition Education and Behavior. Published by Elsevier Inc. All rights reserved.

  5. Accuracy and reliability of linear cephalometric measurements from cone-beam computed tomography scans of a dry human skull.

    Science.gov (United States)

    Berco, Mauricio; Rigali, Paul H; Miner, R Matthew; DeLuca, Stephelynn; Anderson, Nina K; Will, Leslie A

    2009-07-01

    The purpose of this study was to determine the accuracy and reliability of 3-dimensional craniofacial measurements obtained from cone-beam computed tomography (CBCT) scans of a dry human skull. Seventeen landmarks were identified on the skull. CBCT scans were then obtained, with 2 skull orientations during scanning. Twenty-nine interlandmark linear measurements were made directly on the skull and compared with the same measurements made on the CBCT scans. All measurements were made by 2 operators on 4 separate occasions. The method errors were 0.19, 0.21, and 0.19 mm in the x-, y- and z-axes, respectively. Repeated measures analysis of variance (ANOVA) showed no significant intraoperator or interoperator differences. The mean measurement error was -0.01 mm (SD, 0.129 mm). Five measurement errors were found to be statistically significantly different; however, all measurement errors were below the known voxel size and clinically insignificant. No differences were found in the measurements from the 2 CBCT scan orientations of the skull. CBCT allows for clinically accurate and reliable 3-dimensional linear measurements of the craniofacial complex. Moreover, skull orientation during CBCT scanning does not affect the accuracy or the reliability of these measurements.

  6. Intra-observer and interobserver reliability ofOne Leg Stand Test as a measure of posturalbalance in low back pain patients

    DEFF Research Database (Denmark)

    Maribo, Thomas; Iversen, Elena; Andersen, Niels Trolle

    2009-01-01

    Objective: To determine the absolute and relative reliability of intra-observer and interobserver To determine the absolute and relative reliability of intra-observer and interobserver measurements of postural balance using the One Leg Stand Test in patients with low back pain. Patients and methods...... to stand for the maximum time, and no further analysis was done. Eyes closed: intra-observer reliability was tested in 21 patients; absolute reliability showed a standard error of the measurement (SEM) of 2.48 s and a minimal detectable change (MDC) of 6.88. The relative reliability was acceptable...... with an intra class correlation coefficient (ICC) of 0.86. Interobserver reliability was tested in 27 patients; absolute reliability showed a SEM of 1.42 s and a MDC of 3.95. The relative reliability was acceptable with an ICC of 0.91. Conclusions: The One Leg Stand Test can be used to test postural balance...

  7. Synchrotron X-ray PIV Technique for Measurement of Blood Flow Velocity

    International Nuclear Information System (INIS)

    Kim, Guk Bae; Lee, Sang Joon; Je, Jung Ho

    2007-01-01

    Synchrotron X-ray micro-imaging method has been used to observe internal structures of various organisms, industrial devices, and so on. However, it is not suitable to see internal flows inside a structure because tracers typically employed in conventional optical flow visualization methods cannot be detectable with the X-ray micro-imaging method. On the other hand, a PIV (particle image velocimetry) method which has recently been accepted as a reliable quantitative flow visualization technique can extract lots of flow information by applying digital image processing techniques However, it is not applicable to opaque fluids such as blood. In this study, we combined the PIV method and the synchrotron X-ray micro-imaging technique to compose a new X-ray PIV technique. Using the X-ray PIV technique, we investigated the optical characteristics of blood for a coherent synchrotron X-ray beam and quantitatively visualized real blood flows inside an opaque tube without any contrast media. The velocity field information acquired would be helpful for investigating hemorheologic characteristics of the blood flow

  8. Reliability and criterion validity of measurements using a smart phone-based measurement tool for the transverse rotation angle of the pelvis during single-leg lifting.

    Science.gov (United States)

    Jung, Sung-Hoon; Kwon, Oh-Yun; Jeon, In-Cheol; Hwang, Ui-Jae; Weon, Jong-Hyuck

    2018-01-01

    The purposes of this study were to determine the intra-rater test-retest reliability of a smart phone-based measurement tool (SBMT) and a three-dimensional (3D) motion analysis system for measuring the transverse rotation angle of the pelvis during single-leg lifting (SLL) and the criterion validity of the transverse rotation angle of the pelvis measurement using SBMT compared with a 3D motion analysis system (3DMAS). Seventeen healthy volunteers performed SLL with their dominant leg without bending the knee until they reached a target placed 20 cm above the table. This study used a 3DMAS, considered the gold standard, to measure the transverse rotation angle of the pelvis to assess the criterion validity of the SBMT measurement. Intra-rater test-retest reliability was determined using the SBMT and 3DMAS using intra-class correlation coefficient (ICC) [3,1] values. The criterion validity of the SBMT was assessed with ICC [3,1] values. Both the 3DMAS (ICC = 0.77) and SBMT (ICC = 0.83) showed excellent intra-rater test-retest reliability in the measurement of the transverse rotation angle of the pelvis during SLL in a supine position. Moreover, the SBMT showed an excellent correlation with the 3DMAS (ICC = 0.99). Measurement of the transverse rotation angle of the pelvis using the SBMT showed excellent reliability and criterion validity compared with the 3DMAS.

  9. Review of lattice measurement techniques at the SLC

    International Nuclear Information System (INIS)

    Barklow, T.; Emma, P.; Krejcik, P.; Walker, N.

    1991-11-01

    A technique is described for reconstructing the first order transport matrix (R) for a given beam line. Emphasis is placed on the rigorous error analysis of the data, and the use of powerful statistical techniques to estimate unknown systematic errors. The application of the technique to the measurement and subsequent correction of the SLC Arcs is briefly described. 5 refs., 4 figs

  10. Reliability and validity of the Performance Recorder 1 for measuring isometric knee flexor and extensor strength.

    Science.gov (United States)

    Neil, Sarah E; Myring, Alec; Peeters, Mon Jef; Pirie, Ian; Jacobs, Rachel; Hunt, Michael A; Garland, S Jayne; Campbell, Kristin L

    2013-11-01

    Muscular strength is a key parameter of rehabilitation programs and a strong predictor of functional capacity. Traditional methods to measure strength, such as manual muscle testing (MMT) and hand-held dynamometry (HHD), are limited by the strength and experience of the tester. The Performance Recorder 1 (PR1) is a strength assessment tool attached to resistance training equipment and may be a time- and cost-effective tool to measure strength in clinical practice that overcomes some limitations of MMT and HHD. However, reliability and validity of the PR1 have not been reported. Test-retest and inter-rater reliability was assessed using the PR1 in healthy adults (n  =  15) during isometric knee flexion and extension. Criterion-related validity was assessed through comparison of values obtained from the PR1 and Biodex® isokinetic dynamometer. Test-retest reliability was excellent for peak knee flexion (intra-class correlation coefficient [ICC] of 0.96, 95% CI: 0.85, 0.99) and knee extension (ICC  =  0.96, 95% CI: 0.87, 0.99). Inter-rater reliability was also excellent for peak knee flexion (ICC  =  0.95, 95% CI: 0.85, 0.99) and peak knee extension (ICC  =  0.97, 95% CI: 0.91, 0.99). Validity was moderate for peak knee flexion (ICC  =  0.75, 95% CI: 0.38, 0.92) but poor for peak knee extension (ICC  =  0.37, 95% CI: 0, 0.73). The PR1 provides a reliable measure of isometric knee flexor and extensor strength in healthy adults that could be used in the clinical setting, but absolute values may not be comparable to strength assessment by gold-standard measures.

  11. Bayesian methods in reliability

    Science.gov (United States)

    Sander, P.; Badoux, R.

    1991-11-01

    The present proceedings from a course on Bayesian methods in reliability encompasses Bayesian statistical methods and their computational implementation, models for analyzing censored data from nonrepairable systems, the traits of repairable systems and growth models, the use of expert judgment, and a review of the problem of forecasting software reliability. Specific issues addressed include the use of Bayesian methods to estimate the leak rate of a gas pipeline, approximate analyses under great prior uncertainty, reliability estimation techniques, and a nonhomogeneous Poisson process. Also addressed are the calibration sets and seed variables of expert judgment systems for risk assessment, experimental illustrations of the use of expert judgment for reliability testing, and analyses of the predictive quality of software-reliability growth models such as the Weibull order statistics.

  12. Sensitivity, reliability and the effects of diurnal variation on a test battery of field usable upper limb fatigue measures.

    Science.gov (United States)

    Yung, Marcus; Wells, Richard P

    2017-07-01

    Fatigue has been linked to deficits in production quality and productivity and, if of long duration, work-related musculoskeletal disorders. It may thus be a useful risk indicator and design and evaluation tool. However, there is limited information on the test-retest reliability, the sensitivity and the effects of diurnal fluctuation on field usable fatigue measures. This study reports on an evaluation of 11 measurement tools and their 14 parameters. Eight measures were found to have test-retest ICC values greater than 0.8. Four measures were particularly responsive during an intermittent fatiguing condition. However, two responsive measures demonstrated rhythmic behaviour, with significant time effects from 08:00 to mid-afternoon and early evening. Action tremor, muscle mechanomyography and perceived fatigue were found to be most reliable and most responsive; but additional analytical considerations might be required when interpreting daylong responses of MMG and action tremor. Practitioner Summary: This paper presents findings from test-retest and daylong reliability and responsiveness evaluations of 11 fatigue measures. This paper suggests that action tremor, muscle mechanomyography and perceived fatigue were most reliable and most responsive. However, mechanomyography and action tremor may be susceptible to diurnal changes.

  13. Human reliability assessors guide: an overview

    International Nuclear Information System (INIS)

    Humphreys, P.

    1988-01-01

    The Human Reliability Assessors Guide 1 provides a review of techniques currently available for the quantification of Human Error Probabilities. The Guide has two main objectives. The first is to provide a clear and comprehensive description of eight major techniques which can be used to assess human reliability. This is supplemented by case studies taken from practical applications of each technique to industrial problems. The second objective is to provide practical guidelines for the selection of techniques. The selection process is aided by reference to a set of criteria against which each of the eight techniques have been evaluated. Utilising the criteria and critiques, a selection method is presented. This is designed to assist the potential user in choosing the technique, or combination of techniques, most suited to answering the users requirements. For each of the eight selected techniques, a summary of the origins of the technique is provided, together with a method description, detailed case studies, abstracted case studies and supporting references. (author)

  14. Multi-scale full-field measurements and near-wall modeling of turbulent subcooled boiling flow using innovative experimental techniques

    Energy Technology Data Exchange (ETDEWEB)

    Hassan, Yassin A., E-mail: y-hassan@tamu.edu

    2016-04-01

    for the accuracy and to complement these innovative techniques, redundant and simultaneous measurements are performed by means of thermocouples, flow and power meters, differential and absolute pressure transducers, etc. The present experiments are intended to improve the understanding of subcooled boiling flow and to provide reliable and accurate subcooled boiling flow experimental information for verification and validation of two-phase flow computational models.

  15. Reliability of cervical lordosis and global sagittal spinal balance measurements in adolescent idiopathic scoliosis.

    Science.gov (United States)

    Vidal, Christophe; Ilharreborde, Brice; Azoulay, Robin; Sebag, Guy; Mazda, Keyvan

    2013-06-01

    Radiological reproducibility study. To assess intra and interobserver reliability of radiographic measurements for global sagittal balance parameters and sagittal spine curves, including cervical spine. Sagittal spine balance in adolescent idiopathic scoliosis (AIS) is a main issue and many studies have been reported, showing that coronal and sagittal deformities often involve sagittal cervical unbalance. Global sagittal balance aims to obtain a horizontal gaze and gravity line at top of hips when subject is in a static position, involving adjustment of each spine curvature in the sagittal plane. To our knowledge, no study did use a methodologically validated imaging analysis tool able to appreciate sagittal spine contours and distances in AIS and especially in the cervical region. Lateral full-spine low-dose EOS radiographs were performed in 75 patients divided in three groups (control subjects, AIS, operated AIS). Three observers digitally analyzed twice each radiograph and 11 sagittal measures were collected for each image. Reliability was assessed calculating intraobserver Pearson's r correlation coefficient, interobserver intra-class correlation coefficient (ICC) completed with a two-by-two Bland-Altman plot analysis. This measurement method has shown excellent intra and interobserver reliability in all parameters, sagittal curvatures, pelvic parameters and global sagittal balance. This study validated a simple and efficient tool in AIS sagittal contour analysis. It defined new relevant landmarks allowing to characterize cervical segmental curvatures and cervical involvement in global balance.

  16. A GA based penalty function technique for solving constrained redundancy allocation problem of series system with interval valued reliability of components

    Science.gov (United States)

    Gupta, R. K.; Bhunia, A. K.; Roy, D.

    2009-10-01

    In this paper, we have considered the problem of constrained redundancy allocation of series system with interval valued reliability of components. For maximizing the overall system reliability under limited resource constraints, the problem is formulated as an unconstrained integer programming problem with interval coefficients by penalty function technique and solved by an advanced GA for integer variables with interval fitness function, tournament selection, uniform crossover, uniform mutation and elitism. As a special case, considering the lower and upper bounds of the interval valued reliabilities of the components to be the same, the corresponding problem has been solved. The model has been illustrated with some numerical examples and the results of the series redundancy allocation problem with fixed value of reliability of the components have been compared with the existing results available in the literature. Finally, sensitivity analyses have been shown graphically to study the stability of our developed GA with respect to the different GA parameters.

  17. Design techniques for large scale linear measurement systems

    International Nuclear Information System (INIS)

    Candy, J.V.

    1979-03-01

    Techniques to design measurement schemes for systems modeled by large scale linear time invariant systems, i.e., physical systems modeled by a large number (> 5) of ordinary differential equations, are described. The techniques are based on transforming the physical system model to a coordinate system facilitating the design and then transforming back to the original coordinates. An example of a three-stage, four-species, extraction column used in the reprocessing of spent nuclear fuel elements is presented. The basic ideas are briefly discussed in the case of noisy measurements. An example using a plutonium nitrate storage vessel (reprocessing) with measurement uncertainty is also presented

  18. Assessment of the reliability of ultrasonic inspection methods

    International Nuclear Information System (INIS)

    Haines, N.F.; Langston, D.B.; Green, A.J.; Wilson, R.

    1982-01-01

    The reliability of NDT techniques has remained an open question for many years. A reliable technique may be defined as one that, when rigorously applied by a number of inspection teams, consistently finds then correctly sizes all defects of concern. In this paper we report an assessment of the reliability of defect detection by manual ultrasonic methods applied to the inspection of thick section pressure vessel weldments. Initially we consider the available data relating to the inherent physical capabilities of ultrasonic techniques to detect cracks in weldment and then, independently, we assess the likely variability in team to team performance when several teams are asked to follow the same specified test procedure. The two aspects of 'capability' and 'variability' are brought together to provide quantitative estimates of the overall reliability of ultrasonic inspection of thick section pressure vessel weldments based on currently existing data. The final section of the paper considers current research programmes on reliability and presents a view on how these will help to further improve NDT reliability. (author)

  19. Integration of nondestructive examination reliability and fracture mechanics

    International Nuclear Information System (INIS)

    Doctor, S.R.; Bates, D.J.; Charlot, L.A.

    1985-01-01

    The primary pressure boundaries (pressure vessels and piping) of nuclear power plants are in-service inspected (ISI) according to the rules of ASME Boiler and Pressure Vessel Code, Section XI. Ultrasonic techniques are normally used for these inspections, which are periodically performed on a sampling of welds. The Integration of Nondestructive Examination (NDE) Reliability and Fracture Mechanics (FM) Program at Pacific Northwest Laboratory was established to determine the reliability of current ISI techniques and to develop recommendations that will ensure a suitably high inspection reliability. The objectives of this NRC program are to: 1) determine the reliability of ultrasonic ISI performed on commercial light-water reactor primary systems; 2) using probabilistic FM analysis, determine the impact of NDE unreliability on system safety and determine the level of inspection reliability required to ensure a suitably low failure probability; 3) evaluate the degree of reliability improvement that could be achieved using improved and advanced NDE techniques; and 4) based on material properties, service conditions, and NDE uncertainties, formulate recommended revisions to ASME Code, Section XI, and Regulatory Requirements needed to ensure suitably low failure probabilities

  20. Reliability and validity of the brief multidimensional measure of religiousness/spirituality among adolescents.

    Science.gov (United States)

    Harris, Sion Kim; Sherritt, Lon R; Holder, David W; Kulig, John; Shrier, Lydia A; Knight, John R

    2008-12-01

    Developed for use in health research, the Brief Multidimensional Measure of Religiousness/Spirituality (BMMRS) consists of brief measures of a broad range of religiousness and spirituality (R/S) dimensions. It has established psychometric properties among adults, but little is known about its appropriateness for use with adolescents. We assessed the psychometric properties of the BMMRS among adolescents. We recruited a racially diverse (85% non-White) sample of 305 adolescents aged 12-18 years (median 16 yrs, IQR 14-17) from 3 urban medical clinics; 93 completed a retest 1 week later. We assessed internal consistency and test-retest reliability. We assessed construct validity by examining how well the measures discriminated groups expected to differ based on self-reported religious preference, and how they related to a hypothesized correlate, depressive symptoms. Religious preference was categorized into "No religion/Atheist" (11%), "Don't know/Confused" (9%), or "Named a religion" (80%). Responses to multi-item measures were generally internally consistent (alpha > or = 0.70 for 12/16 measures) and stable over 1 week (intraclass correlation coefficients > or = 0.70 for 14/16). Forgiveness, Negative R/S Coping, and Commitment items showed lower internal cohesiveness. Scores on most measures were higher (p Atheist" group. Forgiveness, Commitment, and Anticipated Support from members of one's congregation were inversely correlated with depressive symptoms, while BMMRS measures assessing negative R/S experiences (Negative R/S Coping, Negative Interactions with others in congregation, Loss in Faith) were positively correlated with depressive symptoms. These findings suggest that most BMMRS measures are reliable and valid for use among adolescents.