WorldWideScience

Sample records for relative tl efficiencies

  1. Evaluation of the relative thermoluminescence efficiency of LiF:Mg,Ti and LiF:Mg,Cu,P TL detectors to low-energy heavy ions

    DEFF Research Database (Denmark)

    Gieszczyk, W.; Bilski, P.; Olko, P.

    2013-01-01

    and xenon ion beams, at energies ranging from 5.0 to 9.3 MeV/n. Supra- and sublinear response was found, for the MTS-N and MCP-N, respectively, similarly as observed for γ-rays. However, the level of nonlinearity of response of studied detectors is strongly reduced by increasing values of the ion ionization...... density (no supralinearity for Xe ions, for MTS-N, within calculated uncertainties). The growth of high-temperature TL peaks, with increasing ionization density, was observed for MCP-N, what was not previously reported. At the whole range of applied energies higher efficiencies were noted for MTS......-N, for all ion species. A decrease of the efficiency with decrease of the ion energy was confirmed, for both types of studied detectors. At a given energy, higher efficiency was observed for lighter ions, because of the lower ionization density. Significantly higher decrease of the efficiency was measured...

  2. Alpha efficiency under TL and OSL - A subtraction technique using OSL and TL to detect artificial irradiation

    International Nuclear Information System (INIS)

    Zink, A.J.C.; Dabis, S.; Porto, E.; Castaing, J.

    2010-01-01

    With the development of thermoluminescence (TL) and optically stimulated luminescence (OSL) to determine the authenticity of old ceramics, forgers use artificial irradiation by gamma ray to age modern productions. Besides fraudulent action, objects can be exposed to various sources of X-rays (e.g. radiography, security control at airports). For all these reasons, the determination of artificial irradiation is an important topic for dating art objects. The main technique to identify artificial irradiations is the subtraction technique. It is based on the fact that alpha efficiency varies according to the luminescence technique (fine grain, coarse grains, predose, OSL). Having observed a rather significant difference of alpha efficiency for TL and OSL, we propose a new subtraction technique using OSL and TL of fine grains.

  3. Determination of the full energy peak efficiency of NaI(Tl) detectors

    International Nuclear Information System (INIS)

    Cesana, A.; Terrani, M.

    1978-01-01

    A simple procedure for the accurate evaluation of the full energy peak efficiency of NaI(Tl) crystals is described. Particular attention is given to the peak to total ratio determination for which a new method is proposed. (author)

  4. Exploration of GaInTlP and related Tl-containing III-V alloys for photovoltaics

    International Nuclear Information System (INIS)

    Friedman, D. J.; Kurtz, Sarah R.; Kibbler, A. E.

    1999-01-01

    This paper discusses the results of an attempt to grow GaInTlP for application as a 1-eV material for the third junction of a GaInP/GaAs/3rd-junction high-efficiency solar cell. Although early indications from the literature were promising, we are unable to produce crystalline homogeneous material, and so we conclude that this material is not a promising candidate for such applications as photovoltaics

  5. Simulation of the peak efficiency for a stacked NaI(Tl) spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Yoshida, H; Murohka, H; Anami, K; Nohtomi, A; Uozumi, Y; Sakae, T; Matoba, M [Kyushu Univ., Fukuoka (Japan). Faculty of Engineering; Koori, N; Maki, T

    1996-07-01

    A stacked NaI(Tl) spectrometer has been developed to measure proton spectra in wide energy range. In the measurement of charged particles with intermediate energy, the detecting efficiency of the spectrometer decreases considerably due to nuclear reactions or out-scattering in the detector material. A Monte Carlo simulation code has been developed to estimate the peak efficiency (peak-to-total ratio) of the spectrometer. The calculated efficiency for intermediate energy is in good agreement with the experimental one. (author)

  6. Activation energies from blue- and red-thermoluminescence (TL) of quartz grains and mean lives of trapped electrons related to natural red-TL

    International Nuclear Information System (INIS)

    Hashimoto, T.; Kojima, M.; Shirai, N.; Ichino, M.

    1993-01-01

    A three-dimensional representation of thermoluminescence (TL) spectra has been established by employing an image intensifier unit combined with a simple spectrophotometer and a microcomputer. By means of this TL spectrometric system, natural quartz grains could be distinguished as either blue-and/or red-TL ones. In these blue- and red-TL wavelength regions, activation energies from artificially irradiated quartz grains are evaluated using a repeated initial rise method. An apparent difference of activation energies in the two colorations was observed for dune sands presumably originating from different quartz sources. On the other hand, quartz grains extracted from a volcanic ash sediment showed completely similar activation energies in both TL color regions over all temperatures. Subsequently, the kinetic parameters were derived for the naturally occurring red-TL, possessing an apparent single peak around 340 o C, from volcanically originating quartz grains by fitting a theoretical equation to the glow curves, after evaluating activation energies. On the basis of the empirical kinetic parameters, the mean life of trapped electrons relating to a main 340 o C peak has been proved to be 1 million years, and a secondary weak peak around 280 o C in the natural red-TL glow curve has been confirmed. (author)

  7. Calculated Absolute Detection Efficiencies of Cylindrical Nal (Tl) Scintillation Crystals for Aqueous Spherical Sources

    Energy Technology Data Exchange (ETDEWEB)

    Strindehag, O; Tollander, B

    1968-08-15

    Calculated values of the absolute total detection efficiencies of cylindrical scintillation crystals viewing spherical sources of various sizes are presented. The calculation is carried out for 2 x 2 inch and 3 x 3 inch Nal(Tl) crystals and for sources which have the radii 1/4, 1/2, 3/4 and 1 times the crystal radius. Source-detector distances of 5-20 cm and gamma energies in the range 0.1 - 5 MeV are considered. The correction factor for absorption in the sample container wall and in the detector housing is derived and calculated for a practical case.

  8. T-L Plane Abstraction-Based Energy-Efficient Real-Time Scheduling for Multi-Core Wireless Sensors

    Directory of Open Access Journals (Sweden)

    Youngmin Kim

    2016-07-01

    Full Text Available Energy efficiency is considered as a critical requirement for wireless sensor networks. As more wireless sensor nodes are equipped with multi-cores, there are emerging needs for energy-efficient real-time scheduling algorithms. The T-L plane-based scheme is known to be an optimal global scheduling technique for periodic real-time tasks on multi-cores. Unfortunately, there has been a scarcity of studies on extending T-L plane-based scheduling algorithms to exploit energy-saving techniques. In this paper, we propose a new T-L plane-based algorithm enabling energy-efficient real-time scheduling on multi-core sensor nodes with dynamic power management (DPM. Our approach addresses the overhead of processor mode transitions and reduces fragmentations of the idle time, which are inherent in T-L plane-based algorithms. Our experimental results show the effectiveness of the proposed algorithm compared to other energy-aware scheduling methods on T-L plane abstraction.

  9. Scintillation efficiency measurement of Na recoils in NaI(Tl) below the DAMA/LIBRA energy threshold

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Jingke; Shields, Emily; Calaprice, Frank; Westerdale, Shawn; Froborg, Francis; Suerfu, Burkhant; Alexander, Thomas; Aprahamian, Ani; Back, Henning O.; Casarella, Clark; Fang, Xiao; Gupta, Yogesh K.; Ianni, Aldo; Lamere, Edward; Lippincott, W. Hugh; Liu, Qian; Lyons, Stephanie; Siegl, Kevin; Smith, Mallory; Tan, Wanpeng; Kolk, Bryant Vande

    2015-07-01

    The dark matter interpretation of the DAMA modulation signal depends on the NaI(Tl) scintillation efficiency of nuclear recoils. Previous measurements for Na recoils have large discrepancies, especially in the DAMA/LIBRA modulation energy region. We report a quenching effect measurement of Na recoils in NaI(Tl) from 3 to 52 keVnr, covering the whole DAMA/LIBRA energy region for dark matter-Na scattering interpretations. By using a low-energy, pulsed neutron beam, a double time-of-flight technique, and pulse-shape discrimination methods, we obtained the most accurate measurement of this kind for NaI(Tl) to date. The results differ significantly from the DAMA reported values at low energies but fall between the other previous measurements. We present the implications of the new quenching results for the dark matter interpretation of the DAMA modulation signal.

  10. Full energy peak efficiency of NaI(Tl) gamma detectors and its analytical and semi-empirical representations

    International Nuclear Information System (INIS)

    Sudarshan, M.; Joseph, J.; Singh, R.

    1992-01-01

    The validity of various analytical functions and semi-empirical formulae proposed for representing the full energy peak efficiency (FEPE) curves of Ge(Li) and HPGe detectors has been tested for the FEPE of 7.6 cm x 7.6 cm and 5 cm x 5 cm Nal(Tl) detectors in the gamma energy range from 59.5 to 1408.03 keV. The functions proposed by East, and McNelles and Campbell provide by far the best representations of the present data. The semi-empirical formula of Mowatt describes the present data very well. The present investigation shows that some of the analytical functions and semi-empirical formulae, which represent the FEPE of the Ge(Li) and HPGe detectors very well, can be quite fruitfully used for Nal(Tl) detectors. (Author)

  11. Comparison of total experimental and theoretical absolute γ-ray detection efficiencies of a cylindrical NaI(Tl) crystal

    International Nuclear Information System (INIS)

    Uosif, M.A.; El-Taher, A.

    2005-01-01

    A new fit function has been developed to calculate theoretically the absolute gamma ray detection efficiencies (ηTh) of a cylindrical NaI(Tl) crystal, for calculating the absolute efficiency at any interesting gamma energy in the energy range between 10 and 1300 keV and distance between 0 and 8 cm. The total absolute gamma ray detection efficiencies have been calculated for five detectors, four are 2x2 and one is 3x 3 inches NaI(Tl) crystal at different distances. The absolute efficiency of the different detectors was calculated at the specific energy of the standard sources for each measuring distances. In this calculation, experimental (ηExp) and theoretical (ηTh) have been calculated. The uncertainties of efficiency calibration have been calculated also for quality control. Measurements were performed with calibrated point source. Gamma-ray energies under consideration were 0.356, 0.662, 1.17 and 1.33 MeV. The differences between (ηExp) and (ηTh) at these energies are 1.30E-06, 7.99E-05, 2.29E-04 and 2.42E-04 respectively. The results obtained on the basis of (ηExp) and (ηTh) seem to be in very good agreement

  12. Relative response of TL and component-resolved OSL to alpha and beta radiations in annealed sedimentary quartz

    International Nuclear Information System (INIS)

    Polymeris, George S.; Afouxenidis, Dimitrios; Raptis, Spyridoula; Liritzis, Ioannis; Tsirliganis, Nestor C.; Kitis, George

    2011-01-01

    Knowledge of the relative luminescence response to alpha and beta radiation is very important in TL and OSL dating. In the present study the relative alpha to beta response is studied in a sedimentary quartz sample, previously fired at 900 deg. C for 1 h, in the dose region between 1 and 128 Gy, for both thermoluminescence (TL) and linearly modulated optically stimulated luminescence (LM - OSL). The LM - OSL measurements were performed at room temperature and at 125 deg. C. All OSL signals were deconvolved into their individual components. Comparison of OSL curves after alpha and beta irradiation strongly supports that quartz OSL components follow first order kinetics in both cases. In the case of TL, the relative alpha to beta response is found to be very different for each TL glow-peak, but it does not depend strongly on irradiation dose. In the case of LM - OSL measurements, it is found that the relative behaviour of the alpha to beta response is different for three distinct regions, namely the fast OSL component, the region of medium OSL component originating from the TL glow-peak at 110 deg. C when stimulation takes place at room temperature and finally the region of slow OSL component. Following stimulation at ambient temperature, the relative alpha to beta response of all components was not observed to depend significantly on dose, with the value of ratio being 0.03 and a tendency to decrease with increasing dose. However, in the case of measurements performed at 125 deg. C, the relative response of the fast components is much enhanced, and for the remaining components it increases with increasing dose. Special care must be taken to examine the relative alpha to beta response of the fast component at 125 deg. C which contrasts the relative response of the TL peak at ca. 325 deg. C. The implications for the dating of annealed quartz are also briefly discussed. - Highlights: → Relative alpha to beta response for TL and LM-OSL is studied in annealed

  13. Serial right ventricle 201Tl imaging after exercise: relation to anatomy of the right coronary artery

    International Nuclear Information System (INIS)

    Brown, K.A.; Boucher, C.A.; Okada, R.D.; Strauss, H.W.; McKusick, K.A.; Pohost, G.M.

    1982-01-01

    The relation of the appearance of the right ventricle on serium 201 Tl myocardial imaging to coronary artery anatomy was examined in 88 consecutive patients undergoing exercise 201 Tl testing and coronary angiography for the evaluation of chest pain. Transient defects in the right ventricle were found in 8 patients. All had high grade (greater than or equal to 90%) stenosis of the proximal right coronary artery. Nonvisualization of right ventricular (RV) activity occurred in 10 patients. Nine of the 10 (90%) had significant (greater than or equal to 50% stenosis) disease of the proximal right coronary artery and 7 (70%) had high grade stenosis. The right ventricle appeared normal in 70 patients. Twenty-nine (41%) of these patients had significant proximal right coronary artery disease. Right ventricular appearance was not affected by the presence or absence of disease of the left anterior descending or left circumflex artery or by the appearance of the left ventricle. Thus, with serial RV thallium-201 myocardial imaging after exercise, we found that (1) RV transient defects suggest the presence of high grade proximal right coronary artery stenosis, (2) non-visualization of RV activity also predicts significant proximal right coronary disease, and (3) the right ventricle frequently appears normal despite proximal right coronary artery disease and therefore this finding does not exclude such disease

  14. Calculation of the relative efficiency of thermoluminescent detectors to space radiation

    International Nuclear Information System (INIS)

    Bilski, P.

    2011-01-01

    Thermoluminescent (TL) detectors are often used for measurements of radiation doses in space. While space radiation is composed of a mixture of heavy charged particles, the relative TL efficiency depends on ionization density. The question therefore arises: what is the relative efficiency of TLDs to the radiation present in space? In the attempt to answer this question, the relative TL efficiency of two types of lithium fluoride detectors for space radiation has been calculated, based on the theoretical space spectra and the experimental values of TL efficiency to ion beams. The TL efficiency of LiF:Mg,Ti detectors for radiation encountered at typical low-Earth’s orbit was found to be close to unity, justifying a common application of these TLDs to space dosimetry. The TL efficiency of LiF:Mg,Cu,P detectors is significantly lower. It was found that a shielding may have a significant influence on the relative response of TLDs, due to changes caused in the radiation spectrum. In case of application of TLDs outside the Earth’s magnetosphere, one should expect lower relative efficiency than at the low-Earth’s orbit.

  15. Photopeak efficiency response function of an underwater gamma-ray NaI(Tl) detector using MCNP-X

    International Nuclear Information System (INIS)

    Salgado, William L.; Silva, Ademir X.; Salgado, Cesar M.

    2015-01-01

    This work presents a study to calculate the response function of a 1.5″ x 1″ NaI(Tl) scintillation detector when it is used in the marine environment in the energy range from 20 keV to 662 keV. The method takes into account both the scattering of photons in the water and the detection mechanism of the detector. In addition, the calculation of the response function of the whole system is essential for suppressing the background of the measurement and for estimating the concentration of the involved radionuclides, especially given the greater probability of primary gamma photons undergoing multiple scattering events before they interact with the detector. The experimental photopeak efficiency measurements for point sources were compared with the simulated results under the same conditions of the experimental setup to validate the simulation of the detector. Monte Carlo simulations were performed using the MCNP-X code for the investigation of gamma-ray absorption in water in different brines. The energy resolution curve was used to improve the response of the mathematical simulation of the detector. The detector’s simulation was based on information obtained from the gammagraphy technique. Both dimensions and materials were used for the calculation with the MCNP-X code. The photopeak efficiency of a NaI(Tl) detector for different radionuclides in the aquatic environment with different salinities was calculated. (author)

  16. Calculation of total counting efficiency of a NaI(Tl) detector by hybrid Monte-Carlo method for point and disk sources

    Energy Technology Data Exchange (ETDEWEB)

    Yalcin, S. [Education Faculty, Kastamonu University, 37200 Kastamonu (Turkey)], E-mail: yalcin@gazi.edu.tr; Gurler, O.; Kaynak, G. [Department of Physics, Faculty of Arts and Sciences, Uludag University, Gorukle Campus, 16059 Bursa (Turkey); Gundogdu, O. [Department of Physics, School of Engineering and Physical Sciences, University of Surrey, Guildford GU2 7XH (United Kingdom)

    2007-10-15

    This paper presents results on the total gamma counting efficiency of a NaI(Tl) detector from point and disk sources. The directions of photons emitted from the source were determined by Monte-Carlo techniques and the photon path lengths in the detector were determined by analytic equations depending on photon directions. This is called the hybrid Monte-Carlo method where analytical expressions are incorporated into the Monte-Carlo simulations. A major advantage of this technique is the short computation time compared to other techniques on similar computational platforms. Another advantage is the flexibility for inputting detector-related parameters (such as source-detector distance, detector radius, source radius, detector linear attenuation coefficient) into the algorithm developed, thus making it an easy and flexible method to apply to other detector systems and configurations. The results of the total counting efficiency model put forward for point and disc sources were compared with the previous work reported in the literature.

  17. Calculation of total counting efficiency of a NaI(Tl) detector by hybrid Monte-Carlo method for point and disk sources

    International Nuclear Information System (INIS)

    Yalcin, S.; Gurler, O.; Kaynak, G.; Gundogdu, O.

    2007-01-01

    This paper presents results on the total gamma counting efficiency of a NaI(Tl) detector from point and disk sources. The directions of photons emitted from the source were determined by Monte-Carlo techniques and the photon path lengths in the detector were determined by analytic equations depending on photon directions. This is called the hybrid Monte-Carlo method where analytical expressions are incorporated into the Monte-Carlo simulations. A major advantage of this technique is the short computation time compared to other techniques on similar computational platforms. Another advantage is the flexibility for inputting detector-related parameters (such as source-detector distance, detector radius, source radius, detector linear attenuation coefficient) into the algorithm developed, thus making it an easy and flexible method to apply to other detector systems and configurations. The results of the total counting efficiency model put forward for point and disc sources were compared with the previous work reported in the literature

  18. Global parameterization and validation of a two-leaf light use efficiency model for predicting gross primary production across FLUXNET sites: TL-LUE Parameterization and Validation

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Yanlian [Jiangsu Provincial Key Laboratory of Geographic Information Science and Technology, School of Geographic and Oceanographic Sciences, Nanjing University, Nanjing China; Joint Center for Global Change Studies, Beijing China; Wu, Xiaocui [International Institute for Earth System Sciences, Nanjing University, Nanjing China; Joint Center for Global Change Studies, Beijing China; Ju, Weimin [International Institute for Earth System Sciences, Nanjing University, Nanjing China; Jiangsu Center for Collaborative Innovation in Geographic Information Resource Development and Application, Nanjing China; Chen, Jing M. [International Institute for Earth System Sciences, Nanjing University, Nanjing China; Joint Center for Global Change Studies, Beijing China; Wang, Shaoqiang [Key Laboratory of Ecosystem Network Observation and Modeling, Institute of Geographic Sciences and Natural Resources Research, Chinese Academy of Science, Beijing China; Wang, Huimin [Key Laboratory of Ecosystem Network Observation and Modeling, Institute of Geographic Sciences and Natural Resources Research, Chinese Academy of Science, Beijing China; Yuan, Wenping [State Key Laboratory of Earth Surface Processes and Resource Ecology, Future Earth Research Institute, Beijing Normal University, Beijing China; Andrew Black, T. [Faculty of Land and Food Systems, University of British Columbia, Vancouver British Columbia Canada; Jassal, Rachhpal [Faculty of Land and Food Systems, University of British Columbia, Vancouver British Columbia Canada; Ibrom, Andreas [Department of Environmental Engineering, Technical University of Denmark (DTU), Kgs. Lyngby Denmark; Han, Shijie [Institute of Applied Ecology, Chinese Academy of Sciences, Shenyang China; Yan, Junhua [South China Botanical Garden, Chinese Academy of Sciences, Guangzhou China; Margolis, Hank [Centre for Forest Studies, Faculty of Forestry, Geography and Geomatics, Laval University, Quebec City Quebec Canada; Roupsard, Olivier [CIRAD-Persyst, UMR Ecologie Fonctionnelle and Biogéochimie des Sols et Agroécosystèmes, SupAgro-CIRAD-INRA-IRD, Montpellier France; CATIE (Tropical Agricultural Centre for Research and Higher Education), Turrialba Costa Rica; Li, Yingnian [Northwest Institute of Plateau Biology, Chinese Academy of Sciences, Xining China; Zhao, Fenghua [Key Laboratory of Ecosystem Network Observation and Modeling, Institute of Geographic Sciences and Natural Resources Research, Chinese Academy of Science, Beijing China; Kiely, Gerard [Environmental Research Institute, Civil and Environmental Engineering Department, University College Cork, Cork Ireland; Starr, Gregory [Department of Biological Sciences, University of Alabama, Tuscaloosa Alabama USA; Pavelka, Marian [Laboratory of Plants Ecological Physiology, Institute of Systems Biology and Ecology AS CR, Prague Czech Republic; Montagnani, Leonardo [Forest Services, Autonomous Province of Bolzano, Bolzano Italy; Faculty of Sciences and Technology, Free University of Bolzano, Bolzano Italy; Wohlfahrt, Georg [Institute for Ecology, University of Innsbruck, Innsbruck Austria; European Academy of Bolzano, Bolzano Italy; D' Odorico, Petra [Grassland Sciences Group, Institute of Agricultural Sciences, ETH Zurich Switzerland; Cook, David [Atmospheric and Climate Research Program, Environmental Science Division, Argonne National Laboratory, Argonne Illinois USA; Arain, M. Altaf [McMaster Centre for Climate Change and School of Geography and Earth Sciences, McMaster University, Hamilton Ontario Canada; Bonal, Damien [INRA Nancy, UMR EEF, Champenoux France; Beringer, Jason [School of Earth and Environment, The University of Western Australia, Crawley Australia; Blanken, Peter D. [Department of Geography, University of Colorado Boulder, Boulder Colorado USA; Loubet, Benjamin [UMR ECOSYS, INRA, AgroParisTech, Université Paris-Saclay, Thiverval-Grignon France; Leclerc, Monique Y. [Department of Crop and Soil Sciences, College of Agricultural and Environmental Sciences, University of Georgia, Athens Georgia USA; Matteucci, Giorgio [Viea San Camillo Ed LellisViterbo, University of Tuscia, Viterbo Italy; Nagy, Zoltan [MTA-SZIE Plant Ecology Research Group, Szent Istvan University, Godollo Hungary; Olejnik, Janusz [Meteorology Department, Poznan University of Life Sciences, Poznan Poland; Department of Matter and Energy Fluxes, Global Change Research Center, Brno Czech Republic; Paw U, Kyaw Tha [Department of Land, Air and Water Resources, University of California, Davis California USA; Joint Program on the Science and Policy of Global Change, Massachusetts Institute of Technology, Cambridge USA; Varlagin, Andrej [A.N. Severtsov Institute of Ecology and Evolution, Russian Academy of Sciences, Moscow Russia

    2016-04-06

    Light use efficiency (LUE) models are widely used to simulate gross primary production (GPP). However, the treatment of the plant canopy as a big leaf by these models can introduce large uncertainties in simulated GPP. Recently, a two-leaf light use efficiency (TL-LUE) model was developed to simulate GPP separately for sunlit and shaded leaves and has been shown to outperform the big-leaf MOD17 model at 6 FLUX sites in China. In this study we investigated the performance of the TL-LUE model for a wider range of biomes. For this we optimized the parameters and tested the TL-LUE model using data from 98 FLUXNET sites which are distributed across the globe. The results showed that the TL-LUE model performed in general better than the MOD17 model in simulating 8-day GPP. Optimized maximum light use efficiency of shaded leaves (εmsh) was 2.63 to 4.59 times that of sunlit leaves (εmsu). Generally, the relationships of εmsh and εmsu with εmax were well described by linear equations, indicating the existence of general patterns across biomes. GPP simulated by the TL-LUE model was much less sensitive to biases in the photosynthetically active radiation (PAR) input than the MOD17 model. The results of this study suggest that the proposed TL-LUE model has the potential for simulating regional and global GPP of terrestrial ecosystems and it is more robust with regard to usual biases in input data than existing approaches which neglect the bi-modal within-canopy distribution of PAR.

  19. Dependence of NaI(Tl) detector intrinsic efficiency on source ...

    Indian Academy of Sciences (India)

    on source–detector distance, energy and off-axis distance: Their ... This d/R value at which minimum efficiency occurs approaches zero as off- axis distance ... It should be noted at this point that from the point of view of radiation protection ...

  20. Light regimes differentially affect baseline transcript abundance of stress-axis and (neurodevelopment-related genes in zebrafish (Danio rerio, Hamilton 1822 AB and TL larvae

    Directory of Open Access Journals (Sweden)

    Ruud van den Bos

    2017-11-01

    Full Text Available Many strains of zebrafish (Danio rerio are readily available. Earlier we observed differences between AB and Tupfel long-fin (TL larvae regarding baseline hypothalamus-pituitary-interrenal (HPI axis activity and (neurodevelopment. Light regimes, i.e. 14 h light:10 h dark and 24 h continuous dark or light, affect hatching rate and larval growth. Here, we assessed baseline transcript abundance of HPI-axis-related genes and (neurodevelopment-related genes of AB and TL larvae (5 days post fertilisation using these light regimes. A principal component analysis revealed that in AB larvae the baseline expression of HPI-axis-related genes was higher the more hours of light, while the expression of (neurodevelopment-related genes was higher under 14 h light:10 h dark than under both continuous light or dark. In TL larvae, a complex pattern emerged regarding baseline expression of HPI-axis-related and (neurodevelopment-related genes. These data extend data of earlier studies by showing that light regimes affect gene-expression in larvae, and more importantly so, strengthen the notion of differences between larvae of the AB and TL strain. The latter finding adds to the growing database of phenotypical differences between zebrafish of the AB and TL strain.

  1. Spectral measurements of loess TL

    International Nuclear Information System (INIS)

    Rendell, H.M.; Mann, S.J.; Townsend, P.D.

    1988-01-01

    Variations in thermoluminescence (TL) glow curves are reported for two loess samples when examined with broad band filters in the range 275-650 nm. Samples show striking differences in bleaching behaviour, when their TL emissions are observed in the u.v., blue, green and yellow spectral regions. The age estimates, given by the equivalent dose (ED) values, differ by up to a factor of two for analyses using the green and u.v. TL signals. These ED values also vary with prolonged room temperature storage between the bleaching and irradiation steps. The anomalies in the bleaching behaviour are interpreted in terms of changes in TL efficiency. The results have major implications for the regeneration method of TL dating for these fine-grained sediments and suggest that reliable dates obtained by it may be fortuitous. (author)

  2. Efficiency calibration and coincidence summing correction for large arrays of NaI(Tl) detectors in soccer-ball and castle geometries

    International Nuclear Information System (INIS)

    Anil Kumar, G.; Mazumdar, I.; Gothe, D.A.

    2009-01-01

    Efficiency calibration and coincidence summing correction have been performed for two large arrays of NaI(Tl) detectors in two different configurations. They are, a compact array of 32 conical detectors of pentagonal and hexagonal shapes in soccer-ball geometry and an array of 14 straight hexagonal NaI(Tl) detectors in castle geometry. Both of these arrays provide a large solid angle of detection, leading to considerable coincidence summing of gamma rays. The present work aims to understand the effect of coincidence summing of gamma rays while determining the energy dependence of efficiencies of these two arrays. We have carried out extensive GEANT4 simulations with radio-nuclides that decay with a two-step cascade, considering both arrays in their realistic geometries. The absolute efficiencies have been simulated for gamma energies from 700 to 2800 keV using four different double-photon emitters, namely, 60 Co, 46 Sc, 94 Nb and 24 Na. The efficiencies so obtained have been corrected for coincidence summing using the method proposed by Vidmar et al. . The simulations have also been carried out for the same energies assuming mono-energetic point sources, for comparison. Experimental measurements have also been carried out using calibrated point sources of 137 Cs and 60 Co. The simulated and the experimental results are found to be in good agreement. This demonstrates the reliability of the correction method for efficiency calibration of two large arrays in very different configurations.

  3. Efficiency calibration and coincidence summing correction for large arrays of NaI(Tl) detectors in soccer-ball and castle geometries

    Energy Technology Data Exchange (ETDEWEB)

    Anil Kumar, G., E-mail: anilg@tifr.res.i [Department of Nuclear and Atomic Physics, Tata Institute of Fundamental Research, Homi Bhabha Road, Colaba, Mumbai 400005 (India); Mazumdar, I.; Gothe, D.A. [Department of Nuclear and Atomic Physics, Tata Institute of Fundamental Research, Homi Bhabha Road, Colaba, Mumbai 400005 (India)

    2009-11-21

    Efficiency calibration and coincidence summing correction have been performed for two large arrays of NaI(Tl) detectors in two different configurations. They are, a compact array of 32 conical detectors of pentagonal and hexagonal shapes in soccer-ball geometry and an array of 14 straight hexagonal NaI(Tl) detectors in castle geometry. Both of these arrays provide a large solid angle of detection, leading to considerable coincidence summing of gamma rays. The present work aims to understand the effect of coincidence summing of gamma rays while determining the energy dependence of efficiencies of these two arrays. We have carried out extensive GEANT4 simulations with radio-nuclides that decay with a two-step cascade, considering both arrays in their realistic geometries. The absolute efficiencies have been simulated for gamma energies from 700 to 2800 keV using four different double-photon emitters, namely, {sup 60}Co, {sup 46}Sc, {sup 94}Nb and {sup 24}Na. The efficiencies so obtained have been corrected for coincidence summing using the method proposed by Vidmar et al. . The simulations have also been carried out for the same energies assuming mono-energetic point sources, for comparison. Experimental measurements have also been carried out using calibrated point sources of {sup 137}Cs and {sup 60}Co. The simulated and the experimental results are found to be in good agreement. This demonstrates the reliability of the correction method for efficiency calibration of two large arrays in very different configurations.

  4. Enhancement of thermoelectric efficiency of CoSb3-based skutterudites by double filling with K and Tl

    Directory of Open Access Journals (Sweden)

    Ken eKurosaki

    2014-10-01

    Full Text Available The high-temperature thermoelectric properties of thallium (Tl and potassium (K double-filled cobalt antimonide (CoSb3-based skutterudites with nominal compositions TlxK0.3Co4Sb12 (x = 0.1–0.3 were investigated. The filling fraction of Tl in CoSb3 was enhanced by co-filling with K, which resulted in all of the samples showing the filled-skutterudite single phase. Owing to the high filling ratio, the carrier concentration in the sample with x = 0.3 was as high as 4.3 × 1020 cm−3 at room temperature. Furthermore, quite low lattice thermal conductivity (as low as 0.9 W m−1 K−1 was obtained for the sample with x = 0.3, probably because of strong phonon scattering by the Tl and K co-rattling effect, which resulted in a maximum zT of around one at 773 K.

  5. Study of method of efficiency transference using detectors NaI(Ti); Estudo de método de transferência de eficiência usando detectores NaI(Tl)

    Energy Technology Data Exchange (ETDEWEB)

    Ramos, Thiago L.; Salgado, César M., E-mail: thiago_lins-ramos@hotmail.com, E-mail: otero@ien.gov.br [Instituto de Engenharia Nuclear (IEN/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2017-07-01

    The use of NaI (Tl) scintillation detectors for measurements implies the determination of the detection efficiency as a function of the energy of the incident photons. The efficiency curve can be obtained experimentally with the use of several mono-energy sources calibrated with emission energies covering the whole range of interest or using the Monte Carlo method. The Institute of Nuclear Engineering develops several methodologies using these detectors as they are robust, inexpensive and do not need cooling for their use. The assembly of an experimental arrangement is usually complex, since several factors influence the result affecting reproducibility in measurements, such as: parallelism between source and detector, alignment between source and detector, and accuracy of source-detector distance. In view of such difficulties, an automated positioning system was developed for the source-detector set controlled by a micro controller based on the ARDUINO language in order to guarantee the reproducibility in the experimental arrangements. In the initial phase of this study, a mathematical model was developed in the MCNP-X code using a NaI (Tl) detector. A theoretical validation using the Efficiency Transfer Method was performed at three different positions on the detector's axial axis (10.6 cm, 11.3 cm and 12.0 cm). This method is based on the ratio of effective solid angles. The experimental validation presented maximum relative errors of 7.74% for the position 11.3 cm.

  6. 205Tl experiment

    International Nuclear Information System (INIS)

    Henning, W.; Kutschera, W.; Ernst, H.

    1984-01-01

    205 Tl has been previously proposed as a geological detector for solar neutrinos, making use of the reaction 205 Tl(nu, e - ) 205 Pb with a neutrino threshold of only approx. = 43 keV. We report on an experiment performed to study the feasibility of detecting radioactive 205 Pb nuclei (T/sub 1/2/ = 15 million years) at very low concentrations using the recently developed technique of accelerator mass spectrometry. Employing the high-energy ion beams of good quality from the UNILAC heavy-ion accelerator at the GSI Darmstadt, we are able to demonstrate a suppression of neighbouring isotopes to better than 1 in 10 16 and of neighbouring elements to about 1 in 10 3 . While these results are very encouraging, the minimum number of atoms detectable is still severely limited by the efficiency of producing multiply-charged ions from present ion sources. Future improvements in ion-source performance are briefly discussed

  7. Calibration of a single hexagonal NaI(Tl) detector using a new numerical method based on the efficiency transfer method

    Energy Technology Data Exchange (ETDEWEB)

    Abbas, Mahmoud I., E-mail: mabbas@physicist.net [Physics Department, Faculty of Science, Alexandria University, 21511 Alexandria (Egypt); Badawi, M.S. [Physics Department, Faculty of Science, Alexandria University, 21511 Alexandria (Egypt); Ruskov, I.N. [Frank Laboratory of Neutron Physics, Joint Institute for Nuclear Research, 141980 Dubna (Russian Federation); Institute for Nuclear Research and Nuclear Energy, Bulgarian Academy of Sciences, 1784 Sofia (Bulgaria); El-Khatib, A.M. [Physics Department, Faculty of Science, Alexandria University, 21511 Alexandria (Egypt); Grozdanov, D.N. [Frank Laboratory of Neutron Physics, Joint Institute for Nuclear Research, 141980 Dubna (Russian Federation); Institute for Nuclear Research and Nuclear Energy, Bulgarian Academy of Sciences, 1784 Sofia (Bulgaria); Thabet, A.A. [Department of Medical Equipment Technology, Faculty of Allied Medical Sciences, Pharos University in Alexandria (Egypt); Kopatch, Yu.N. [Frank Laboratory of Neutron Physics, Joint Institute for Nuclear Research, 141980 Dubna (Russian Federation); Gouda, M.M. [Physics Department, Faculty of Science, Alexandria University, 21511 Alexandria (Egypt); Skoy, V.R. [Frank Laboratory of Neutron Physics, Joint Institute for Nuclear Research, 141980 Dubna (Russian Federation)

    2015-01-21

    Gamma-ray detector systems are important instruments in a broad range of science and new setup are continually developing. The most recent step in the evolution of detectors for nuclear spectroscopy is the construction of large arrays of detectors of different forms (for example, conical, pentagonal, hexagonal, etc.) and sizes, where the performance and the efficiency can be increased. In this work, a new direct numerical method (NAM), in an integral form and based on the efficiency transfer (ET) method, is used to calculate the full-energy peak efficiency of a single hexagonal NaI(Tl) detector. The algorithms and the calculations of the effective solid angle ratios for a point (isotropic irradiating) gamma-source situated coaxially at different distances from the detector front-end surface, taking into account the attenuation of the gamma-rays in the detector's material, end-cap and the other materials in-between the gamma-source and the detector, are considered as the core of this (ET) method. The calculated full-energy peak efficiency values by the (NAM) are found to be in a good agreement with the measured experimental data.

  8. Myocardium scintigraphy with 201Tl in assessment of efficiency of thrombolytic therapy in patients with acute myocardial infarction

    International Nuclear Information System (INIS)

    Savel'ev, V.Yu.; Sergienko, V.B.; Smirnov, A.A.

    1989-01-01

    The results of perfusion scintigraphy in patients which were treated with thrombolytic therapy depending on the efficiency of coronary blood flow recovery are compared. Reliable tendency to the reduction of disease focus in patients with myocardial infarction when the coronary blood flow is recovered is detected in investigations that proves the clinical efficiency of thrombolytic therapy. 12 refs.; 3 tabs

  9. ABA content in shoots and roots of pea mutants af and tl as related to their growth and morphogenesis

    Czech Academy of Sciences Publication Activity Database

    Kof, E.M.; Vinogradova, I.A.; Oorzhak, A.S.; Karyagin, V.V.; Kalibernaya, Z.V.; Macháčková, Ivana; Kondykov, I.V.; Chuvasheva, E.S.

    2006-01-01

    Roč. 53, č. 3 (2006), s. 359-365 ISSN 1021-4437 Institutional research plan: CEZ:AV0Z50380511 Keywords : Pisum sativum * af and tl leaf mutants * morphogenesis Subject RIV: EF - Botanics Impact factor: 0.321, year: 2006

  10. Relative efficiency calculation of a HPGe detector using MCNPX code

    International Nuclear Information System (INIS)

    Medeiros, Marcos P.C.; Rebello, Wilson F.; Lopes, Jose M.; Silva, Ademir X.

    2015-01-01

    High-purity germanium detectors (HPGe) are mandatory tools for spectrometry because of their excellent energy resolution. The efficiency of such detectors, quoted in the list of specifications by the manufacturer, frequently refers to the relative full-energy peak efficiency, related to the absolute full-energy peak efficiency of a 7.6 cm x 7.6 cm (diameter x height) NaI(Tl) crystal, based on the 1.33 MeV peak of a 60 Co source positioned 25 cm from the detector. In this study, we used MCNPX code to simulate a HPGe detector (Canberra GC3020), from Real-Time Neutrongraphy Laboratory of UFRJ, to survey the spectrum of a 60 Co source located 25 cm from the detector in order to calculate and confirm the efficiency declared by the manufacturer. Agreement between experimental and simulated data was achieved. The model under development will be used for calculating and comparison purposes with the detector calibration curve from software Genie2000™, also serving as a reference for future studies. (author)

  11. Doped Tl-1212 and Tl-1223 superconductors

    International Nuclear Information System (INIS)

    Eder, M.H.

    2001-09-01

    This work describes the preparation and characterization of thallium-lead-strontium-barium-calcium-(uranium)-copperoxide (Tl-1212, Tl-1223) high-temperature superconductors. The precursors were prepared via nitrate method. After calcination the oxidic powders were mixed with stoichiometric amounts of an Tl 2 O 3 , PbO, Er 2 O 3 and Gd 2 O 3 by milling and afterwards uniaxial compressed. Sintering was carried out in silver foils. X-ray diffractometry and high-resolution microscopy in combination with scanning electron microscopy (including EDAX) were used to study the influence of varying thallium/lead-, strontium/barium-, calcium/rare earth element ratios and the effect of uranium on the phase composition and microstructure of bulk superconductors. Furthermore the influence of the composition on the electrical and magnetical properties was studied. On phase pure Tl-1212 and Tl-1223 superconductors NMR-measurements were done. Small amounts of gadolinium and erbium instead of calcium and excess-uranium have a positive impact on the electrical and magnetical properties of the Tl-1223 superconductors. Higher amounts of these doping elements favor the Tl-1212 phase. Tl-1212 superconductors with varying thallium/lead- strontium/barium- and calcium/gadolinium ratios were prepared phasepure in wide range of doping. Transition temperatures up to 96 K were achieved. It was shown that lead has an oxidation number of +4 and thallium of +3. (author)

  12. Relative thermoluminescent efficiencies proton/gamma and helium/gamma of peaks of high temperature in TLD-100 dosemeters

    International Nuclear Information System (INIS)

    Flores M, E.

    2007-01-01

    The increase of the applications of ion beams in radiotherapy treatments has generated interest in the study of the thermoluminescent materials (TL) that allow to determine the applied doses. A way to quantify the TL response from these materials to ions is by means of the relative thermoluminescent efficiency. In the group of Thermoluminescent dosimetry of the Institute of Physics of the UNAM (IFUNAM) the thermoluminescent response of the TLD-100 dosemeters has been studied, which present a glow curve characteristic with several peaks that correspond to traps and luminescent centers in the material. The stable peaks know each other as 4, 5, 6a, 6b, 7, 8, 9 and 10. The efficiencies should be measured using the response so much to the radiation of interest (in this case protons and helium ions) as the response to gamma radiation. In previous works with ions of low energy taken place in the Pelletron accelerator of the IFUNAM was only measured the TL efficiency for the peak 5 and the total signal. It had not been possible to measure the efficiency of the peaks of high temperature (6a-10) because, for the gamma radiation, the peaks of high temperature show very small signals; however, recently Massillon carries out measures of efficiency TL of peaks of high temperature for ions of intermediate energy using a protocol special of reading and of deconvolution that allows to measure the signals coming from the peaks of high temperature. In this work is implemented this same protocol to complete the study of TL efficiencies at low energy of protons and helium and to determine if the values of efficiency depend on the used reading protocol. For it is reported it measures of the relative efficiency of the peaks of high temperature from the TLD-100 exposed to protons of 1.5 MeV and nuclei of helium of 3 and 7.5 MeV. (Author)

  13. Theories of TL systems: Failures, successes, conflicts, trends: Insights into possible future materials and techniques

    International Nuclear Information System (INIS)

    Horowitz, Y. S.; Belaish, Y.; Oster, L.

    2006-01-01

    In this paper some of the many theoretical models dealing with characteristics of TL materials are discussed. Special attention is given to some of the models dealing with the effects of ionisation density, that is Modified Track Structure Theory (MTST) and Micro-dosimetric Track Structure Theory (MTT) for the calculation of Heavy Charged Particle relative TL efficiencies, as well as solid-state models based on conduction band/valence band theory. Failures, successes, conflicts and trends are highlighted as well as a peek into future avenues of research for dosimetric TL materials. (authors)

  14. Tl{sub 2}LaCl{sub 5} (Ce{sup 3+}): New fast and efficient scintillator for X- and γ-ray detection

    Energy Technology Data Exchange (ETDEWEB)

    Kim, H.J., E-mail: hongjoo@knu.ac.kr [Department of Physics, Kyungpook National University, Daegu 41566 (Korea, Republic of); Rooh, Gul [Department of Physics, Abdul Wali Khan University, Mardan 23200 (Pakistan); Kim, Sunghwan [Department of Radiological Science, Cheongju University, Cheongju 41566 (Korea, Republic of)

    2017-06-15

    Scintillation properties of the new Tl{sub 2}LaCl{sub 5}: xCe{sup 3+} where x=0, 0.5, 1 and 10 mol % (TLC: Ce{sup 3+}) single crystals are presented. Two zones vertical Bridgman technique is used for the growth of this scintillation material. High Z-number (79) of this material offer excellent detection efficiency for X- and γ-rays. Grown samples are characterized under X- and γ-rays excitation in order to find the emission wavelength, energy resolution, light yield, and decay time. Emission spectra exhibit Ce{sup 3+} emission bands between 350–550 nm and peaking at 389 nm. The obtained energy resolution and light yield increases with high Ce-concentration. Energy resolution and light yield of 10%Ce-doped sample are found to be 6.9% (FWHM) and 51,000±5000 ph/MeV, respectively at room temperature. For the grown samples, two exponential decay time constants are found. The measured decay time constants showed variation in their values with respect to Ce-concentrations in the host crystal. Fast decay time constant of 31 ns with 87% light emission is found for 10%Ce sample. Scintillation results suggested that TLC will be one of the promising next generation scintillator for the medical imaging techniques such as Positron Emission Tomography (PET).

  15. Relative thermoluminescent efficiencies proton/gamma and helium/gamma of high temperature peaks in TLD-100 dosemeters

    International Nuclear Information System (INIS)

    Flores M, E.; Avila, O.; Rodriguez V, M.; Massillon, J.L.G.; Buenfil A, E.; Ruiz T, C.; Brandan, M.E.; Gamboa De Buen, I.

    2007-01-01

    This work presents measures of relative thermoluminescent efficiency of those high temperature peaks of TLD-100 dosemeters exposed to protons of 1.5 MeV and to helium nuclei of 3 and 7.5 MeV. A rigorous reading and of deconvolution protocol was used for the calculation of the TL efficiencies. Additionally an Excel program that facilitated the deconvolution adjustment process of the glow curves was elaborated. (Author)

  16. TL transgenic mouse strains

    International Nuclear Information System (INIS)

    Obata, Y.; Matsudaira, Y.; Hasegawa, H.; Tamaki, H.; Takahashi, T.; Morita, A.; Kasai, K.

    1993-01-01

    As a result of abnormal development of the thymus of these mice, TCR αβ lineage of the T cell differentiation is disturbed and cells belonging to the TCR γδ CD4 - CD8 - double negative (DN) lineage become preponderant. The γδ DN cells migrate into peripheral lymphoid organs and constitute nearly 50% of peripheral T cells. Immune function of the transgenic mice is severely impaired, indicating that the γδ cells are incapable of participating in these reactions. Molecular and serological analyses of T-cell lymphomas reveal that they belong to the γδ lineage. Tg.Tla a -3-1 mice should be useful in defining the role of TL in normal and abnormal T cell differentiation as well as in the development of T-cell lymphomas, and further they should facilitate studies on the differentiation and function of γδ T cells. We isolated T3 b -TL gene from B6 mice and constructed a chimeric gene in which T3 b -TL is driven by the promoter of H-2K b . With the chimeric gene, two transgenic mouse strains, Tg. Con.3-1 and -2 have been derived in C3H background. Both strains express TL antigen in various tissues including skin. The skin graft of transgenic mice on C3H and (B6 X C3H)F 1 mice were rejected. In the mice which rejected the grafts, CD8 + TCRαβ cytotoxic T cells (CTL) against TL antigens were recognized. The recognition of TL by CTL did not require the antigen presentation by H-2 molecules. The results indicated that TL antigen in the skin becomes a transplantation antigen and behaves like a typical allogeneic MHC class I antigen. The facts that (B6 X C3H)F 1 mice rejected the skin expressing T3 b -TL antigen and induced CTL that killed TL + lymphomas of B6 origin revealed that TL antigen encoded by T3 b -TL is recognized as non-self in B6 mice. Experiments are now extended to analyze immune responses to TL antigen expressed on autochthonous T cell lymphomas. (J.P.N.)

  17. Phytotoxicity of thallium (Tl) in culture solution. Pt. 1. Effects of Tl(I) on the growth and heavy metal contents of pea and field bean plants

    Energy Technology Data Exchange (ETDEWEB)

    Poetsch, U; Austenfeld, F A

    1985-01-01

    The effects of TlNO/sub 3/ and Tl(I)EDTA on growth and heavy metal contents of pea plants and field bean plants were compared in hydroponic culture experiments. In the presence of TlNO/sub 3/, the essential heavy metals were available to the plants in their ionic forms. When Tl(I)EDTA was present the essential heavy metals were available as chelated complexes. With increasing concentration of TlNO/sub 3/ dry matter production of pea plants was lowered and the Tl content of each organ was increased. The highest Tl content was found within the stems. The increased Tl contents were accompanied by depressed Mn, Zn, and Cu contents of the roots and depressed Mn contents of the stems, but increased Fe contents of the stems. Substitution of TlNO/sub 3/ by Tl(I)EDTA resulted in a stronger growth inhibition of the pea plants, and higher Tl contents of each organ. The highest Tl content was found within the stems. Tl(I)EDTA depressed Mn in the roots, but increased Fe and Mn in the stems, and Fe, Zn and Cu in the leaves. The increases may due to concentration by growth inhibition. The growth of the field bean was not effected by TlNO/sub 3/ nor by Tl(I)EDTA. The field bean contained most of the Tl within the roots and translocated only relatively small amounts to the shoots. This pattern was independent of the Tl compound. Increasing concentrations of TlNO/sub 3/ resulted in depressed Mn and Zn contents of the roots, and Mn contents of the stems. Chelation of Tl(I) resulted in a decrease of the Tl content of each organ. Tl(I)EDTA depressed only the Mn content of the roots.

  18. TL1A regulates TCRγδ+ intraepithelial lymphocytes and gut microbial composition

    DEFF Research Database (Denmark)

    Tougaard, Peter; Skov, S.; Pedersen, A. E.

    2015-01-01

    TL1A is a proinflammatory cytokine, which is prevalent in the gut. High TL1A concentrations are present in patients with inflammatory bowel disease (IBD) and in IBD mouse models. However, the role of TL1A during steady‐state conditions is relatively unknown. Here, we used TL1A knockout (KO) mice ...

  19. TL dosimetric properties BAM:EU

    International Nuclear Information System (INIS)

    Rao, Bellam N.; Murthy, K.V.R.; Subba Rao, B.; Saiprasad, A.S.

    2011-01-01

    In phosphor area today top priority is the replacement of the high performance but very expensive rare earth activated phosphors with cheaper materials. This essentially means replacing the rare earth ions with transition metal ions or post transition ions. Now a day's phosphors are used in various fields. After World War II, the advances in the optical spectroscopy of solids, especially those of transition metals ions help to evolve research on phosphor and solid state luminescence. In 1960 efficient rare earth activated phosphors were developed for use in color TV (Tb 3+ green, Eu 3+ red, and Dy 3+ yellow). In 1970 tricolor lamp was introduced blue emission from Ce 3+ + Tb 3+ pair was used in tricolor lamps. At present combination of halo phosphor and tri-band phosphor blend is used in many lamp as a compromise between performance, phosphor cost and the lamp making Cost. Thermo luminescence of 0.5 Gy X-ray irradiated BAM.Eu has been studied. The irradiated phosphor has been studied for its TL dosimetric properties one week after irradiation and after 100 weeks of storage. Interesting TL results are reported in the present paper. Heating rate used in the present experiment is 6.6 deg C/Sec. The following two figures are on TL recorded 100 weeks after irradiation and TL recorded after 235 weeks of storage. Before storage for 100 weeks the TL glow curve with a hump around 180 deg C followed by a peak at 273 deg C. After storage for 100 weeks the TL pattern changes entirely. i.e. the composite TL peak structure emerged as two well resolved peaks and with slightly higher TL peak temperatures at 215 deg C and 300 deg C. Normally after storage for 100 weeks the peak at 190 deg C reduces in its intensity or disappears in some cases, instead of that the peak appears at 215 deg C as well resolved peak and its intensity is almost comparable to that of 300 deg C peak. Since the TL phenomenon observed is interesting the two well resolved, isolated, high intensity peaks

  20. Intrinsic thermoluminescence of NaCl:Tl in UV dosimetry

    International Nuclear Information System (INIS)

    Barghare, S.P.; Joshi, R.V.; Joshi, T.R.; Kathuria, S.P.

    1982-01-01

    NaCl:Tl(T) phosphor is found to have high intrinsic thermoluminescence (TL) sensitivity to 253.7 nm UV-radiation. The dosimetric glow peak II grows sublinearly with increase in UV dose in the range 10 3 to 10 6 JM -2 . The other requirements of an efficient dosimeter material such as high storage stability, matching of the spectral response of detector tube and TL-emission from phosphor, reproducibility, desirable size and shape, easy availability in powder, pellet and crystal forms at cheaper rates, and repeated re-usability of the same phosphor without much difficulty, etc., are additional factors which strengthen the claim of NaCl:Tl(T) phosphor as UV dosimetric material. It is proposed that present NaCl:Tl(T) material is suitable TL-phosphor for UV dosimetry in the range 10 3 to 10 6 JM -2 . (author)

  1. Determination of turbine relative efficiency in SHPP

    Directory of Open Access Journals (Sweden)

    Džepčeski Dane

    2017-01-01

    Full Text Available To assess the fulfillment of contract conditions for the equipment delivery, determining the properties and capabilities of a generating unit or some part of it, the measurements carried out under real operating conditions were necessary. In this paper, the results of the test that was carried out in a small hydropower plant (SHPP, aimed at determining the relative efficiency of the hydraulic turbine and its comparison with the guaranteed values, are presented. The dependence of the turbine efficiency on the turbine discharge was determined based on the test results, using the index method. The test was performed at one net head.

  2. Regional analysis of annual maximum rainfall using TL-moments method

    Science.gov (United States)

    Shabri, Ani Bin; Daud, Zalina Mohd; Ariff, Noratiqah Mohd

    2011-06-01

    Information related to distributions of rainfall amounts are of great importance for designs of water-related structures. One of the concerns of hydrologists and engineers is the probability distribution for modeling of regional data. In this study, a novel approach to regional frequency analysis using L-moments is revisited. Subsequently, an alternative regional frequency analysis using the TL-moments method is employed. The results from both methods were then compared. The analysis was based on daily annual maximum rainfall data from 40 stations in Selangor Malaysia. TL-moments for the generalized extreme value (GEV) and generalized logistic (GLO) distributions were derived and used to develop the regional frequency analysis procedure. TL-moment ratio diagram and Z-test were employed in determining the best-fit distribution. Comparison between the two approaches showed that the L-moments and TL-moments produced equivalent results. GLO and GEV distributions were identified as the most suitable distributions for representing the statistical properties of extreme rainfall in Selangor. Monte Carlo simulation was used for performance evaluation, and it showed that the method of TL-moments was more efficient for lower quantile estimation compared with the L-moments.

  3. {sup 201}Tl, {sup 99m}Tc-MIBI, {sup 99m}Tc-tetrofosmin and {sup 99m}Tc-furifosmin: relative retention and clearance kinetics in retrogradely perfused guinea pig hearts

    Energy Technology Data Exchange (ETDEWEB)

    Schaefer, Wolfgang M.; Moka, Detlef E-mail: detlef.moka@uni-koeln.de; Brockmann, Holger A.; Schomaecker, Klaus; Schicha, Harald

    2002-02-01

    Myocellular kinetics of {sup 201}Tl, {sup 99m}Tc-MIBI, {sup 99m}Tc-tetrofosmin and {sup 99m}Tc-furifosmin were investigated using retrogradely-perfused guinea-pig hearts. Relative retention decreased in the order {sup 99m}Tc-MIBI {yields}{yields} implies {sup 99m}Tc-tetrofosmin {yields}{yields} implies {sup 99m}Tc-furifosmin. {sup 201}Tl and {sup 99m}Tc-MIBI exhibited bi- (t1,t2), {sup 99m}Tc-tetrofosmin and {sup 99m}Tc-furifosmin triexponential (t1,t2,t3) time-activity-curves. Latest-phase elimination-half-life increased from {sup 201}Tl (t2) {yields}{yields} implies {sup 99m}Tc-MIBI (t2) {yields}{yields} implies {sup 99m}Tc-tetrofosmin (t3) {yields}{yields} implies {sup 99m}Tc-furifosmin (t3), showing a significant increase in deteriorating myocardium for all tracers but {sup 99m}Tc-furifosmin. Delayed elimination in deteriorating myocardium explains at least partly the redistribution phenomenon of {sup 201}Tl, and suggests a similar phenomenon for {sup 99m}Tc-MIBI and {sup 99m}Tc-tetrofosmin.

  4. Range-energy relation, range straggling and response function of CsI(Tl), BGO and GSO(Ce) scintillators for light ions

    CERN Document Server

    Avdeichikov, V; Jakobsson, B; Rodin, A M; Ter-Akopian, G M

    2000-01-01

    Range-energy relations and range straggling of sup 1 sup , sup 2 sup , sup 3 H and sup 4 sup , sup 6 He isotopes with the energy approx 50A MeV are measured for the CsI(Tl), BGO and GSO(Ce) scintillators with an accuracy better than 0.2% and 5%, respectively. The Si-Sci/PD telescope was exposed to secondary beams from the mass separator ACCULINNA. The experimental technique is based on the registration of the 'jump' in the amplitude of the photodiode signal for ions passing through the scintillation crystal. Light response of the scintillators for ions 1<=Z<=4 is measured in energy range (5-50)A MeV, the results are in good agreement with calculations based on Birks model. The energy loss straggling for particles with DELTA E/E=0.01-0.50 and mass up to A=10 in 286 mu m DELTA E silicon detector is studied and compared with theoretical prescriptions. The results allow a precise absolute calibration of the scintillation crystal and to optimize the particle identification by the DELTA E-E(Sci/PD) method.

  5. The neutron diffraction of molten TlCl, TlBr, and TlI

    International Nuclear Information System (INIS)

    Satow, T.; Uemura, O.; Hoshino, K.; Watanabe, T.

    1984-01-01

    Structure factors S(K) for liquid TlCl, TlBr, and TlI are determined by neutron diffraction measurements. Atomic radial distribution functions (RDF) derived from S(K) are presented. All RDF values are slightly smaller than those of their solid state counter parts. Results show that TlX has a tendency not to retain cesium-chloride type local order, but to take sodium-chloride type order when melting

  6. Investigation of TL, OSL and PTTL properties of Mg2SiO4:Tb dosimeters

    International Nuclear Information System (INIS)

    Oguz, K. F.; Goekce, M.; Karali, T.; Harmansah, C.

    2010-01-01

    In this study thermoluminescence (TL) and optically stimulated luminescence (OSL) properties of Mg 2 SiO 4 :Tb in the form of sintered pellets were investigated. Mg 2 SiO 4 :Tb is a recently developed dosimetric material which offers high sensitivity for TL and OSL in dosimetric applications. Thermoluminescence glow curve of Tb doped Mg 2 SiO 4 samples show a glow peak at about 200 degree Celsius with two small peaks at about 275 and 330 degree Celsius, respectively. OSL experiments showed that blue light (470 nm) is six times more efficient than green light (532 nm) to stimulate the OSL emission. The aim of this study was to determine the TL and OSL fading properties of Mg 2 SiO 4 : Tb using OSL and TL methods. In addition, PTTL properties of the Mg 2 SiO 4 : Tb was investigated by using blue LEDs, UV lamp and blue laser. Investigations on the fading properties also showed that the TL signal fades % 10 in a period of 1 month and OSL signal fades % 10 in a period of 3 month, which then the signal remains relatively stable for longer periods.

  7. Prognostic significance of normal quantitative Tl-201 stress scintigraphy in relation to pretest likelihood of coronary artery disease

    International Nuclear Information System (INIS)

    Russo, D.J.; Russo, D.; Clements, J.; Wackers, F.

    1984-01-01

    A previous study reported an excellent prognosis and low cardiac event rate in patients(pts) with chest pain and normal quantitative T1-201 scintigraphy(SC). Such result would not be unexpected if the population under study had a predominance of pts with low pre-T1-201 likelihood(L) of significant coronary artery disease (CAD). Hence, the authors undertook telephone follow-up in pts with chest pain syndrome and normal quantitative T1-201 exercise SC, and related outcome to pretest L of CAD. Pretest L was determined by serial L analysis on the basis of: symptoms, age, sex, and exercise ECG. All pts had T1-201 SC immediately post exercise and 2 hrs later. After interpolative background correction, circumferential count and washout profiles were generated. All pts had unequivocally normal studies. Of a total of 96 pts studied in 1981-82, 20 pts were lost to follow-up. Of the remaining 76 pts, 45 were males and 31 females. The pretest L of CAD had an inverted Gaussian distribution: thirty-four pts(47%) had 66% L of CAD. Mean follow-up was 22+- 3 months. No deaths occurred. Two pts(3%) (with pretest L of 54% and 94%) had myocardial infarctions, 8 and 22 months respectively after T1-201 stress SC. One pt underwent percutaneous transluminal coronary angioplasty (PTCA) 16 months after T1-201 stress SC. These findings confirm excellent prognostic significance of normal quantitative T1-201 stress scintigraphy

  8. Assessment of vascularity and permeability in brain tumor using SPECT and [sup 99m]Tc-DTPA-human serum albumin in relation to [sup 201]Tl SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Nakagawara, Jyoji; Fukuoka, Seiji; Takahashi, Shuhei; Takahashi, Masaaki; Satoh, Katsuyasu; Suematsu, Katsumi; Nakamura, Jun-ichi (Nakamura Memorial Hospital, Sapporo (Japan))

    1994-02-01

    Single photon emission computed tomography (SPECT) using technetium-99m-DTPA-human serum albumin ([sup 99m]Tc-HSA-D) and thallium-201 chloride ([sup 201]Tl) was simultaneously performed on 25 patients with brain tumors; 10 with brain metastasis, 8 with astrocytoma (Gr. 3) and 7 with meningioma. The early image was obtained 10 minutes after [sup 99m]Tc-HSA-D (740 MBq) injection, and the delayed image was taken 5 hours after the injection. HSA-D index, based on the ratio of [sup 99m]Tc-HSA-D uptake in the tumor versus the cortical area, was calculated on each image, and compared with Tl index (tumor/contralateral cerebrum ratio). HSA-D delayed index was significantly greater than HSA-D early index in all tumor types (p<0.05 by the Wilcoxon ranked sign test). Linear correlation between HSA-D early index and HSA-D delayed index was significant in astrocytoma (GR. 3) (p<0.01) and meningioma (p<0.001), and a linear correlation between HSA-D delayed index and Tl index was significant in astrocytoma (Gr. 3) (p<0.05). It is concluded that HSA-D early index and delayed index could reflect tumor vascularity and permeability, respectively, and provide supplementary information for Tl index. (author).

  9. DEA best practice assesses relative efficiency, profitability

    International Nuclear Information System (INIS)

    Taylor, D.T.; Thompson, R.G.

    1995-01-01

    The US Federal Energy Regulatory Commission (FERC), in its Order 636 of Apr. 8, 1992, stated, ''All natural gas suppliers, including pipelines, will compete for gas purchases on an equal footing.'' This FERC order changed the economic environment in the natural gas pipeline industry. Now, gas pipeline companies must know their market position, since rate of return regulation is no longer relevant. They must be managed more than before as companies have been in less-regulated parts of the oil and gas business. How they adapt to the new environment, therefore, can be instructive to companies throughout the energy industry. In this article, DEA best-practice methods measure relative efficiency and profitability potential. This measurement reflects fundamental economic relationships. The operational efficiency model analyzed is as follows: Y 1 = f(x 1 , x 2 ), where Y 1 is gross profits, x 1 is total assets (capital employed), and x 2 is total employees (labor employed). Y 1 is a comprehensive indicator of a pipeline's output, whereas x 1 represents the pipeline's total capital employed, and x 2 represents the pipeline's total labor employed. This model reflects principles long studied in economics

  10. Determination of relative efficiency of a detector using Monte Carlo method

    International Nuclear Information System (INIS)

    Medeiros, M.P.C.; Rebello, W.F.; Lopes, J.M.; Silva, A.X.

    2015-01-01

    High-purity germanium detectors (HPGe) are mandatory tools for spectrometry because of their excellent energy resolution. The efficiency of such detectors, quoted in the list of specifications by the manufacturer, frequently refers to the relative full-energy peak efficiency, related to the absolute full-energy peak efficiency of a 7.6 cm x 7.6 cm (diameter x height) NaI(Tl) crystal, based on the 1.33 MeV peak of a 60 Co source positioned 25 cm from the detector. In this study, we used MCNPX code to simulate an HPGe detector (Canberra GC3020), from Real-Time Neutrongraphy Laboratory of UFRJ, to survey the spectrum of a 60 Co source located 25 cm from the detector in order to calculate and confirm the efficiency declared by the manufacturer. Agreement between experimental and simulated data was achieved. The model under development will be used for calculating and comparison purposes with the detector calibration curve from software Genie2000™, also serving as a reference for future studies. (author)

  11. Performance of Linear and Nonlinear Two-Leaf Light Use Efficiency Models at Different Temporal Scales

    Directory of Open Access Journals (Sweden)

    Xiaocui Wu

    2015-02-01

    Full Text Available The reliable simulation of gross primary productivity (GPP at various spatial and temporal scales is of significance to quantifying the net exchange of carbon between terrestrial ecosystems and the atmosphere. This study aimed to verify the ability of a nonlinear two-leaf model (TL-LUEn, a linear two-leaf model (TL-LUE, and a big-leaf light use efficiency model (MOD17 to simulate GPP at half-hourly, daily and 8-day scales using GPP derived from 58 eddy-covariance flux sites in Asia, Europe and North America as benchmarks. Model evaluation showed that the overall performance of TL-LUEn was slightly but not significantly better than TL-LUE at half-hourly and daily scale, while the overall performance of both TL-LUEn and TL-LUE were significantly better (p < 0.0001 than MOD17 at the two temporal scales. The improvement of TL-LUEn over TL-LUE was relatively small in comparison with the improvement of TL-LUE over MOD17. However, the differences between TL-LUEn and MOD17, and TL-LUE and MOD17 became less distinct at the 8-day scale. As for different vegetation types, TL-LUEn and TL-LUE performed better than MOD17 for all vegetation types except crops at the half-hourly scale. At the daily and 8-day scales, both TL-LUEn and TL-LUE outperformed MOD17 for forests. However, TL-LUEn had a mixed performance for the three non-forest types while TL-LUE outperformed MOD17 slightly for all these non-forest types at daily and 8-day scales. The better performance of TL-LUEn and TL-LUE for forests was mainly achieved by the correction of the underestimation/overestimation of GPP simulated by MOD17 under low/high solar radiation and sky clearness conditions. TL-LUEn is more applicable at individual sites at the half-hourly scale while TL-LUE could be regionally used at half-hourly, daily and 8-day scales. MOD17 is also an applicable option regionally at the 8-day scale.

  12. Relative thermoluminescent efficiencies proton/gamma and helium/gamma of peaks of high temperature in TLD-100 dosemeters; Eficiencias termoluminiscentes relativas proton/gamma y helio/gamma de picos de alta temperatura en dosimetros TLD-100

    Energy Technology Data Exchange (ETDEWEB)

    Flores M, E. [UNAM, Facultad de Ciencias, 04510 Mexico D.F. (Mexico)

    2007-07-01

    The increase of the applications of ion beams in radiotherapy treatments has generated interest in the study of the thermoluminescent materials (TL) that allow to determine the applied doses. A way to quantify the TL response from these materials to ions is by means of the relative thermoluminescent efficiency. In the group of Thermoluminescent dosimetry of the Institute of Physics of the UNAM (IFUNAM) the thermoluminescent response of the TLD-100 dosemeters has been studied, which present a glow curve characteristic with several peaks that correspond to traps and luminescent centers in the material. The stable peaks know each other as 4, 5, 6a, 6b, 7, 8, 9 and 10. The efficiencies should be measured using the response so much to the radiation of interest (in this case protons and helium ions) as the response to gamma radiation. In previous works with ions of low energy taken place in the Pelletron accelerator of the IFUNAM was only measured the TL efficiency for the peak 5 and the total signal. It had not been possible to measure the efficiency of the peaks of high temperature (6a-10) because, for the gamma radiation, the peaks of high temperature show very small signals; however, recently Massillon carries out measures of efficiency TL of peaks of high temperature for ions of intermediate energy using a protocol special of reading and of deconvolution that allows to measure the signals coming from the peaks of high temperature. In this work is implemented this same protocol to complete the study of TL efficiencies at low energy of protons and helium and to determine if the values of efficiency depend on the used reading protocol. For it is reported it measures of the relative efficiency of the peaks of high temperature from the TLD-100 exposed to protons of 1.5 MeV and nuclei of helium of 3 and 7.5 MeV. (Author)

  13. Estimation of infarct size by myocardial emission computed tomography with 201Tl and its relation to creatine kinase-MB release after myocardial infarction in man

    International Nuclear Information System (INIS)

    Tamaki, S.; Nakajima, H.; Murakami, T.

    1982-01-01

    We evaluated emission computed tomography (ECT) 201 Tl myocardial imaging in estimating infarct size (IS). In 18 patients in whom IS was estimated enzymatically at the time of the acute episode, planar 201 Tl perfusion scintigraphy and ECT with a rotating gamma camera were performed 4 weeks after the first myocardial infarction. From the size of 201 Tl perfusion defects, the infarct area in planar images and the infarct volume in reconstructed ECT images were measured by computerized planimetry. When scintigraphic IS was compared with the accumulated creatine kinase-MB isoenzyme release (CK-MBr), infarct volume determined from ECT correlated closely with CK-MBr (r . 0.89), whereas infarct area measured from planar images correlated less satisfactorily with the enzymatic IS (for an average infarct area from three views, r . 0.69; for the largest infarct area, r . 0.73). Although conventional scintigraphic evaluation is useful for detecting and localizing infarction, quantification of ischemic injury with this two-dimensional technique has a significant inherent limitation. The ECT approach can provide a more accurate three-dimensional quantitative estimate of infarction, and can corroborate the enzymatic estimate of IS

  14. Kinetic parameters and TL mechanism in cadmium tetra borate phosphor

    International Nuclear Information System (INIS)

    Annalakshmi, O.; Jose, M.T.; Sridevi, J.; Venkatraman, B.; Amarendra, G.; Mandal, A.B.

    2014-01-01

    Polycrystalline powder samples of cadmium tetra borate were synthesized by a simple solid state sintering technique and gamma irradiated sample showed a simple Thermoluminescence (TL) glow peak around 460 K. The TL kinetic parameters of gamma irradiated phosphor were determined by initial rise (IR), isothermal decay (ID), peak shape (PS), variable heating rate (VHR) and glow curve de-convolution method. The kinetic parameters such as activation energy (E), frequency factor (s) and order of kinetics (b) were calculated by IR, ID, PS and VHR methods are in the order of ∼1.05 eV, 10 9 –10 12 s −1 and 1.58, respectively. From the results of TL and PL emission studies carried out on the phosphor revealed that the defect centers related to TL is different from that for PL. EPR measurements were carried out to identify the defect centers formed in cadmium tetra borate phosphor on gamma irradiation. Based on EPR studies the mechanism for TL process in cadmium tetra borate is proposed in this paper -- Highlights: • Polycrystalline powder samples of undoped cadmium tetra borate synthesized. • Cadmium tetra borate phosphor exhibits a dosimetric peak at 458 K. • Kinetic parameters of the trap responsible for TL evaluated. • TL mechanism is proposed from TL to EPR correlation studies

  15. Kinetic parameters and TL mechanism in cadmium tetra borate phosphor

    Energy Technology Data Exchange (ETDEWEB)

    Annalakshmi, O. [Radiological Safety Division, Materials Physics Division, Indira Gandhi Centre for Atomic Research, Kalpakkam-603102 (India); Jose, M.T., E-mail: mtj@igcar.gov.in [Radiological Safety Division, Materials Physics Division, Indira Gandhi Centre for Atomic Research, Kalpakkam-603102 (India); Sridevi, J. [Central Leather Research Institute, Council of Scientific and Industrial Research, Chennai 600 020, Tamilnadhu (India); Venkatraman, B. [Radiological Safety Division, Materials Physics Division, Indira Gandhi Centre for Atomic Research, Kalpakkam-603102 (India); Amarendra, G. [Materials Physics Division, Indira Gandhi Centre for Atomic Research, Kalpakkam-603102 (India); Mandal, A.B. [Central Leather Research Institute, Council of Scientific and Industrial Research, Chennai 600 020, Tamilnadhu (India)

    2014-03-15

    Polycrystalline powder samples of cadmium tetra borate were synthesized by a simple solid state sintering technique and gamma irradiated sample showed a simple Thermoluminescence (TL) glow peak around 460 K. The TL kinetic parameters of gamma irradiated phosphor were determined by initial rise (IR), isothermal decay (ID), peak shape (PS), variable heating rate (VHR) and glow curve de-convolution method. The kinetic parameters such as activation energy (E), frequency factor (s) and order of kinetics (b) were calculated by IR, ID, PS and VHR methods are in the order of ∼1.05 eV, 10{sup 9}–10{sup 12} s{sup −1} and 1.58, respectively. From the results of TL and PL emission studies carried out on the phosphor revealed that the defect centers related to TL is different from that for PL. EPR measurements were carried out to identify the defect centers formed in cadmium tetra borate phosphor on gamma irradiation. Based on EPR studies the mechanism for TL process in cadmium tetra borate is proposed in this paper -- Highlights: • Polycrystalline powder samples of undoped cadmium tetra borate synthesized. • Cadmium tetra borate phosphor exhibits a dosimetric peak at 458 K. • Kinetic parameters of the trap responsible for TL evaluated. • TL mechanism is proposed from TL to EPR correlation studies.

  16. 201Tl heart studies

    International Nuclear Information System (INIS)

    Bell, R.L.

    1976-01-01

    At the annual meeting of the Society of Nuclear Medicine there was a preponderance of papers dealing with the heart. The most impressive papers detailed the use of monovalent cation 201 Tl in the evaluation of coronary artery disease. Thallium-201 behaves like potassium in that it enters heart muscle quickly and persists in that organ for several hours. It is unlike most radioactive potassium analogues used for heart studies in that: (1) its gamma energy peaks (69 keV and 80 keV) are more easily collimated with resultant image improvement, (2) its physical half life of 72 hours is sufficiently short to attain high counting rates without too much radiation and is sufficiently long so that storage is not prohibitive, (3) its short half life and lack of Beta radiation results in lower radiation to the patient, and (4) its uptake in heart is greater and uptake in liver and stomach less than other potassium analogues

  17. Use of universal functional optimisation for TL glow curve analysis

    International Nuclear Information System (INIS)

    Pernicka, F.; Linh, H.Q.

    1996-01-01

    The effective use of any TL instrument requires an efficient software package to be able to fulfil different tasks required by research and practical applications. One of the standard features of the package used at the NPI Prague is the application of the interactive modular system Universal Functional Optimisation (UFO) for glow curve deconvolution. The whole system has been tested on standard glow curves using different models of the TL process (a single peak described by the Podgorsak approximation, first order kinetics and/or general order kinetics). Calculated values of basic TL parameters (E and s) show a good agreement with the results obtained by other authors. The main advantage of the system is in its modularity that enables flexible changes in the TL model and mathematical procedures of the glow curve analysis. (author)

  18. Comparison of TL profiles in recent sea cores

    Energy Technology Data Exchange (ETDEWEB)

    Castagnoli, G C; Bonino, G

    1985-01-01

    The thermoluminescence (TL) profile of different recent Tyrrhenian sea cores sampled at various intervals during the last centuries have been compared in order to check the reproducibility of the profiles and investigate the possibility of using the results for monitoring solar-terrestrial relations in the past. The satisfactory results obtained by comparison of two different cores in the time interval 1755-1969 A.D. has demonstrated: (a) the two TL profiles are correlated; (b) the 11 yr cycle corresponding to the main solar cycle is evident in both TL profiles.

  19. Photon and neutron energy response of Thermoluminescent (TL) dosimeters

    International Nuclear Information System (INIS)

    Thilagam, L.; Priya, M.R.; Mohapatra, D.K.

    2018-01-01

    Theoretical Monte Carlo (MC) simulations are carried out to investigate the relative thermoluminesence (TL) response of the most commonly used TLD materials to a wide range of photon energy. The effect of polytetrafluoroethylene (PTFE) on TL response of CaSO 4 :Dy is also studied. Additionally, the neutron response of LiF:Mg,Ti TL materials with different concentrations of 6 Li is estimated in terms of the number of 6 Li(n, t) 4 He capture reactions for a wider neutron energy

  20. Relative thermoluminescent efficiencies proton/gamma and helium/gamma of high temperature peaks in TLD-100 dosemeters; Eficiencias termoluminiscentes relativas proton/gamma y helio/gamma de picos de alta temperatura en dosimetros TLD-100

    Energy Technology Data Exchange (ETDEWEB)

    Flores M, E.; Avila, O.; Rodriguez V, M. [ININ, 52750 La Marquesa, Estado de Mexico (Mexico); Massillon, J.L.G.; Buenfil A, E.; Ruiz T, C.; Brandan, M.E. [IFUNAM, 04500 Mexico D.F. (Mexico); Gamboa De Buen, I. [ICN-UNAM, 04500 Mexico D.F. (Mexico)

    2007-07-01

    This work presents measures of relative thermoluminescent efficiency of those high temperature peaks of TLD-100 dosemeters exposed to protons of 1.5 MeV and to helium nuclei of 3 and 7.5 MeV. A rigorous reading and of deconvolution protocol was used for the calculation of the TL efficiencies. Additionally an Excel program that facilitated the deconvolution adjustment process of the glow curves was elaborated. (Author)

  1. Copper interactions in TlCu7S4 and TlCu7Se4

    International Nuclear Information System (INIS)

    Noren, L.; Delaplane, R.G.; Berger, R.

    1999-01-01

    Complete text of publication follows. The copper chalcogenides ACu 7 S 4 (A=NH 4 + , Tl + , Rb + ) are quasi-one-dimensional metals at ambient and higher temperatures which is due to the high mobility of copper in these structures. TlCu 7 S 4 and TlCu 7 Se 4 are isostructural compounds, space group I4/m, which can be described on the basis of a TlX 8 cube with two different Cu sites, Cu(1) and Cu(2). Cu(2)-Cu(2) zigzag chains run along the c axis with only 3/4 occupation of the Cu(2) sites. However, these two compounds differ in behaviour on cooling. The sulphide shows a polymorphic first-order transition to the CsAg 7 S 4 type (P4/n) owing to ordering of the vacancies in the Cu(2)-Cu(2) chains. In order to study the nature of the Cu(2) order/disorder in the two title compounds, a series of neutron diffraction measurements (both Bragg and diffuse scattering) were made at several temperatures from 40 to 713 K on the instrument SLAD at Studsvik. The structure at each temperature was modelled using RMC techniques. The resulting configuration show that as the temperature increases, there is a marked increase in the mobility of the Cu atoms in the Cu(2)-Cu(2) chains for TlCu 7 S 4 but not for TlCu 7 Se 4 . This is due to the initial difference in the Cu(2)-Cu(2) distances, only 2.2A for the thiocuprate, but 2.7A in the selenocuprate which explains the relative ease for Cu(2) ordering in the latter case. (author)

  2. Spectrophotometric determination of Tl carrier in 201Tl-TlCl injection

    International Nuclear Information System (INIS)

    Gong Quansheng; Jing Lie

    1997-01-01

    A simple and sensitive method for the spectrophotometric determination of carrier content (Thallium) in 201 Tl-TlCl injection is described. Thallium (I) is oxidised to Thallium (III) by aqueous bromine, then excess bromine is removed by adding sulfosalicylic acid. In buffer solution (NH 4 Cl-NH 4 OH) at pH 11.7 with the presence of emulsifier OP, thallium (III) and cadion form a complex having an absorption maximum at 469 nm with a molar absorptivity of 1.37 x 10 4 m 2 /mol. Beer's law is obeyed in the concentration range of 0-7 μg/5 mL. The effect of impurity elements in 201 Tl-TlCl injection is examined. It is an ideal method for the analysis of radioactive solution

  3. Evidence on the relation between public capital and Government efficiency

    OpenAIRE

    Francisca Guedes de Oliveira

    2010-01-01

    This paper intends to contribute to the literature by providing empirical evidence on the relation between public capital stock and government efficiency. We present some objective indicators fo government efficiency and explore the mentioned relation. we find a positive and significant relation between both variables that survives the introduction of controls and robustness checking.

  4. Phase diagrams of novel Tl{sub 4}SnSe{sub 4}–TlSbSe{sub 2}–Tl{sub 2}SnSe{sub 3} quasi-ternary system following DTA and X-ray diffraction

    Energy Technology Data Exchange (ETDEWEB)

    Barchiy, I.E.; Tatzkar, A.R. [Department of Chemistry, Uzhgorod National University, Pidgirna St., 46, Uzhgorod 88000 (Ukraine); Fedorchuk, A.O. [Department of Inorganic and Organic Chemistry, Lviv National University of Veterinary Medicine and Biotechnologies, Pekarska St., 50, Lviv 79010 (Ukraine); Plucinski, K., E-mail: kpluc2006@wp.pl [Electronics Department, Military University Technology, Warsaw, Kaliskiego 2, Warsaw 00-908 (Poland)

    2016-06-25

    Phase relation in the Tl{sub 4}SnSe{sub 4}–TlSbSe{sub 2}–Tl{sub 2}SnSe{sub 3} quasiternary system were studied by the DTA and X-ray diffraction in combination with mathematical modeling. The phase diagrams of the Tl{sub 4}SnSe{sub 4}–TlSbSe{sub 2} and Tl{sub 2}SnSe{sub 3}–TlSbSe{sub 2} systems, the perspective views of the phase interaction in the ternary system, the liquidus surface projection, the isothermal section at 423 K were built for the first time. The Tl{sub 4}SnSe{sub 4}–TlSbSe{sub 2}–Tl{sub 2}SnSe{sub 3} system is of the invariant eutectic type and is characterized by the formation of limited solid solutions following initial ternary compounds. New complex compounds are not formed. - Highlights: • Two Tl{sub 4}SnSe{sub 4}–TlSbSe{sub 2},Tl{sub 2}SnSe{sub 3}–TlSbSe{sub 2} systems were explored. • Invariant processes in the ternary system were determined. • New complex compounds were not observed in ternary system.

  5. A preliminary study of landslide gouge dating by TL technique

    Energy Technology Data Exchange (ETDEWEB)

    Fengju, Ji; Jianping, Li [Inst. of Geology, National Seismological Bereau, Beijing (China); Mingda, Liu [Inst. of Crustal Dynamics, SSB, Beijing (China)

    1993-04-01

    The key to date slipping of landslide by TL method is whether the temperature and pressure caused by slipping can lead the original TL to 'zero'for some minerals within the slipping band. For this purpose, the simulated experiments under different temperature-pressure were made and the TL annealing effect of landslide gouge was studied. The results show that the frictional heating caused during slipping is a main factor leading the mineral's TL to decrease on the slip plane and that increment of temperature is in close relation with strength of shear stress, thickness of landslide gouge and amount of displacement. As an example, the slipping age of a paleo-landslide at Huangtupo, Hubei Province, has been dated to be about 140 ka.

  6. Prediction of half-metallic properties in TlCrS{sub 2} and TlCrSe{sub 2} based on density functional theory

    Energy Technology Data Exchange (ETDEWEB)

    Hashimzade, F.M.; Huseinova, D.A. [Institute of Physics, National Academy of Sciences of Azerbaijan, AZ 1143 Baku (Azerbaijan); Jahangirli, Z.A. [Institute of Physics, National Academy of Sciences of Azerbaijan, AZ 1143 Baku (Azerbaijan); Institute of Radiation Problems, National Academy of Sciences of Azerbaijan, AZ 1143 Baku (Azerbaijan); Mehdiyev, B.H., E-mail: bachschi@yahoo.de [Institute of Physics, National Academy of Sciences of Azerbaijan, AZ 1143 Baku (Azerbaijan)

    2017-08-01

    Highlights: • Half-metallic properties of TlCrS2, TlCrSe2 and hypothetical TlCrSSe have been investigated by first-principles all-electron full-potential linearized augmented plane wave plus local orbital (FP-LAPW+lo) method based on density functional theory (DFT). • Total magnetic moment keeps its integer value on a relatively wide range of changes in volume (−10% ÷ 10%) for TlCrS2 and TlCrSSe, while total magnetic moment TlCrSe2 decreases with increasing volume, approaching to integer value 3 μB. • The states at the Fermi level in the case of spin-up channel consist of a hybridization of p-states of the atom S(Se) with d-states of Cr. - Abstract: Half-metallic properties of TlCrS{sub 2}, TlCrSe{sub 2} and hypothetical TlCrSSe have been investigated by first-principles all-electron full-potential linearized augmented plane wave plus local orbital (FP-LAPW+lo) method based on density functional theory (DFT). The results of calculations show that TlCrS{sub 2} and TlCrSSe are half-metals with energy gap (E{sub g}) ∼0.12 eV for spin-down channel. Strong hybridization of p-state of chalchogen and d-state of Cr leads to bonding and antibonding states and subsequently to the appearance of a gap in spin-down channel of TlCrS{sub 2} and TlCrSSe. In the case of TlCrSe{sub 2}, there is a partial hybridization and p-state is partially present in the DOS at Fermi level making this compound nearly half-metallic. The present calculations revealed that total magnetic moment keeps its integer value on a relatively wide range of changes in volume (−10% ÷ 10%) for TlCrS{sub 2} and TlCrSSe, while total magnetic moment of TlCrSe{sub 2} decreases with increasing volume approaching to integer value 3 μB.

  7. Relative fault and efficient negligence: Comparative negligence explained

    NARCIS (Netherlands)

    Dari-Mattiacci, G.; Hendriks, E.S.

    2013-01-01

    This paper shows that the rule of comparative negligence with relative fault - a sharing of the loss proportional to the parties’ relative departures from due care - induces the parties to an accident to be efficiently negligent. Comparative negligence is more efficient than simple or contributory

  8. NaI(Tl) response functions

    International Nuclear Information System (INIS)

    Vega C, H. R.; Ortiz R, J. M.; Benites R, J. L.; De Leon M, H. A.

    2015-09-01

    The response functions of a NaI(Tl) detector have been estimated using Monte Carlo methods. Response functions were calculated for monoenergetic photon sources (0.05 to 3 MeV). Responses were calculated for point-like sources and for sources distributed in Portland cement cylinders. The responses were used to calculate the efficiency functions in term of photon energy. Commonly, sources used for calibration are point-like, and eventually sources to be measured have different features. In order to use the calibrated sources corrections due to solid angle, self-absorption and scattering, must be carried out. However, some of these corrections are not easy to perform. In this work, the calculated responses were used to estimate the detector efficiency of point-like sources, and sources distributed in Portland type cement. Samples of Portland paste were prepared and were exposed to photoneutrons produced by a 15 MV linac. Some of the elements in the cement were activated producing γ-emitting radionuclides that were measured with a NaI(Tl) gamma-ray spectrometer, that was calibrated with point-like sources. In order to determine the specific activity in the induced radioisotopes calculated efficiencies were used to make corrections due to the differences between the solid angle, photon absorption and photon scattering in the point-like calibration sources and the sources distributed in cement. During the interaction between photoneutrons and the cement samples three radioisotopes were induced: 56 Mn, 24 Na, and 28 Al. (Author)

  9. Improving TL dosimetry for external radiotherapy

    International Nuclear Information System (INIS)

    Bustos, S.R.; Velez, G.; Rubio, M.

    1998-01-01

    Full text: In vivo thermoluminescence dosimetry (TLD) has always been one of the most accurate dosimetry method for external radiotherapy control, but the delay in the response is a well know drawback when it is applied. In this work we show some improvements and demonstrate that keeping the precision and accuracy of this technique, it is possible to obtain a response in few hours. Harshaw 4000 TL reader and LiF TLD-100 dosimeters, chips (3,1 x 3,1 x 0,9 mm 3 ) and rods (1 x 1 x 6 mm 3 ) have been used. The thermal treatment necessary to reuse the TLD is only 1h at 400 degree C, by using a glow curve analyser developed at the Ciemat (Spain), that allows a complete, prompt and precise identification of the individuals peaks. The dosimeters are periodically and individually calibrated. We also have study the factors contributing to the relation TL-dose like linearity, energy correction, directional response and fading. All those results are included into an Excel worksheet which automatically give us the dose resulting from the TL reading (peaks areas 4 and 5). The obtained uncertainty is better than 5%. The TLD already irradiated in radiotherapy institutions distant 30-40 Km from our centre can be read and analysed in about 3-4 hours. These facts render our methods rapid and allow a better control of radiotherapy treatment even if it is bi-fractionated. (author) [es

  10. Natural quartz TL property and similarity in Piper nigrum L

    International Nuclear Information System (INIS)

    Guzman A, S.; Cruz Z, E.; Furetta, C.; Brown, F.; Barboza F, M.

    2009-10-01

    Quartz is a mineral abundant in nature and can provide information thermoluminescent (TL), and also is located in the mineral fraction of some herbs and spices consumed. It is present the analysis of the TL properties of a sample of natural quartz rock and compared with those obtained from the fraction of Piper nigrum L. poly mineral when they were exposed to 60 Co gamma radiation. The poly minerals of Piper nigrum L. were analyzed by X-ray diffraction, where the quartz was found as a major component. They separated in different particle sizes (10, 53, 74 and 149 μm). The samples were irradiated at relatively low doses (1-500 Gy) and high (0.1-40 kGy) in order to determine the linearity of the TL emission as a function of the dose and the analysis of glow curves. Also there was the fading of the TL signal, the effect of ultra violet light. The reproducibility of the TL signal in the samples indicates that a smaller particle size gives better TL signal. (author)

  11. Tl Cuprate Superconductors Studied by XPS

    Energy Technology Data Exchange (ETDEWEB)

    Vasquez, R. P. [Jet Propulsion Laboratory, California Institute of Technology, Pasadena, CA 91109-8099 (United States); Siegal, M. P. [Sandia National Laboratories, Albuquerque, NM 87185-1421 (United States); Overmyer, D. L. [Sandia National Laboratories, Albuquerque, NM 87185-1421 (United States); Ren, Z. F. [Department of Chemistry, State University of New York, Buffalo, NY 14260-3000 (United States); Lao, J. Y. [Department of Chemistry, State University of New York, Buffalo, NY 14260-3000 (United States); Wang, J. H. [Department of Chemistry, State University of New York, Buffalo, NY 14260-3000 (United States)

    1999-07-01

    XPS measurements on epitaxial thin films of the Tl cuprate superconductors Tl2Ba2CaCu2O8, Tl2Ba2Ca2Cu3O10, and Tl0.78Bi0.22Ba0.4Sr1.6Ca2Cu3O9-{delta} are presented. These data, together with previous measurements in this lab on Tl2Ba2CuO6-{delta} and TlBa2CaCu2O7-{delta}, comprise a comprehensive data set for comparison of Tl cuprates in which the number of Tl-O and Cu-O layers, and hence the chemical and electronic properties, vary. (c) 2000 American Vacuum Society.

  12. Tl Cuprate Superconductors Studied by XPS

    International Nuclear Information System (INIS)

    Vasquez, R. P.; Siegal, M. P.; Overmyer, D. L.; Ren, Z. F.; Lao, J. Y.; Wang, J. H.

    1999-01-01

    XPS measurements on epitaxial thin films of the Tl cuprate superconductors Tl2Ba2CaCu2O8, Tl2Ba2Ca2Cu3O10, and Tl0.78Bi0.22Ba0.4Sr1.6Ca2Cu3O9-δ are presented. These data, together with previous measurements in this lab on Tl2Ba2CuO6-δ and TlBa2CaCu2O7-δ, comprise a comprehensive data set for comparison of Tl cuprates in which the number of Tl-O and Cu-O layers, and hence the chemical and electronic properties, vary. (c) 2000 American Vacuum Society

  13. Relative efficiency of the radiothermoluminescence induced by 238Pu alpha-particles in LiF:Mg, Al2O3 and CaSO4:Dy

    International Nuclear Information System (INIS)

    Vicy, Masok.

    1978-01-01

    This work represents a comparative study of the radiothermoluminescence (R.T.L.) induced by 60 Co gamma rays and 238 Pu alpha-particles in three R.T.L. materials: lithium fluoride, alumina and dysprosium activated calcium sulphate. The T.L. glow curves induced by the two radiations are very similar. However, for the same absorbed dose, different sensitivity is seen to each form of irradiation. Measurements of the relative R.T.L. efficiency, epsilon, were made in the linear zone (dose [fr

  14. Myocardial viability assessed by Tl-201 SPECT. Redistribution versus reinjection

    International Nuclear Information System (INIS)

    Chalela, William Azem; Pimentel, Flavio Ferrarini de Oliveira; Uchida, Augusto Hiroshi; Bottega, Augusto; Ramires, Jose Antonio Franchine; Izaki, Marisa; Moraes, Aguinaldo Pereira; Soares Junior, Jose; Giorgi, Maria C. Pinto; Moffa, Paulo Jorge; Bellotti, Giovanni; Giovanni Guido Cerri; Meneghetti, Jose Claudio

    1994-01-01

    The purpose of this study was to verify if a third series of images acquired by reinjection thallium-201, 24 h after conventional myocardial perfusion with the radioisotope, improves the identification of myocardial viability segments. The methods: we studied 30 patients, mean age 57.7 ±9.4 years, with old myocardial infarction using thallium (Tl)-201 SPECT, and we obtained three series of images (stress, redistribution after 4 h and reinjection after 24 h. Cardiac images were divided in 5 segments (apical, lateral, anterior, septal and inferior) and each one received a value by a score system according to the Tl-201 myocardial uptake (0=normal uptake; 1=mild hypoperfusion; 2=moderate hypoperfusion; 3=severe hypoperfusion or no myocardial uptake). We considered viable myocardium when the uptake of Tl-201 in the segment related to te myocardial infarction increases at least 1 point in two different axis of Tl-201 SPECT. The results: seven (23,3%) patients demonstrated increase of Tl-201 uptake only at reinjection images, showing a high efficacy of the method. Nine (30%) patients showed persistent hypoperfusion at all series of images suggesting only fibrosis in the are related to the infarction. Fourteen (46,7%) patients showed increase of Tl-201 concentration at redistribution images; among these patients, six showed improvement of myocardial uptake at reinjection. This condition was interpreted as regional chronic ischemic process: hibernating myocardium. The conclusion was that Tl-201 hypoperfusion at redistribution images without significant changes in relation to the stress images do not represent fibrosis at all. The reinjection technic was better than conventional redistribution in the detection of viable myocardium. This data allows a better therapeutic orientation. (author)

  15. Chemical bonding in Tl cuprates studied by x-ray photoemission

    International Nuclear Information System (INIS)

    Vasquez, R.P.; Siegal, M.P.; Overmyer, D.L.; Ren, Z.F.; Lao, J.Y.; Wang, J.H.

    1999-01-01

    Epitaxial thin films of the Tl cuprate superconductors Tl 2 Ba 2 CaCu 2 O 8 , Tl 2 Ba 2 Ca 2 Cu 3 O 10 , and Tl 0.78 Bi 0.22 Ba 0.4 Sr 1.6 Ca 2 Cu 3 O 9-δ are studied with x-ray photoemission spectroscopy. These data, together with previous measurements in this lab of Tl 2 Ba 2 CuO 6+δ and TlBa 2 CaCu 2 O 7-δ , comprise a comprehensive data set for a comparative study of Tl cuprates with a range of chemical and electronic properties. In the Cu 2p spectra, a larger energy separation between the satellite and main peaks (E s -E m ) and a lower intensity ratio (I s /I m ) are found to correlate with higher values of T c . Analysis of these spectra within a simple configuration interaction model suggests that higher values of T c are related to low values of the O 2p→Cu 3d charge transfer energy. In the O 1s region, a smaller bond length between Ba and Cu-O planar oxygen is found to correlate with a lower binding energy for the signal associated with Cu-O bonding, most likely resulting from the increased polarization screening by Ba 2+ ions. For samples near optimum doping, maximum T c is observed to occur when the Tl 4f 7/2 binding energy is near 117.9 eV, which is near the middle of the range of values observed for Tl cuprates. Higher Tl 4f 7/2 binding energies, corresponding to formal oxidation states nearer Tl 1+ , are also found to correlate with longer bond lengths between Ba and Tl-O planar oxygen, and with higher binding energies of the O 1s signal associated with Tl-O bonding. copyright 1999 The American Physical Society

  16. TL response to quartz and aluminum oxide grain for α-irradiation

    International Nuclear Information System (INIS)

    Pan Baolin; Wei Mingjian; Li Dongxu; Liu Zhaowen; Liu Chao; Zhao Shiyuan

    2009-01-01

    Thermoluminescence (TL) response for an α-ray irradiation system ( 241 Am) was examined with quartz grains of 11-40 μm. Quartz grains of different sizes, i.e. 137 Cs), before they were irradiated to different doses by the α-ray irradiation system. TL response to the quartz grain samples was measured. TL response of the quartz grains smaller than 4 μm and 11-40 μm to α-ray irradiation is the best, as the α-rays cannot penetrate quartz larger than 40 μm. The TL response characteristic is related with quartz grain surface area. TL responses to α-irradiation of 11-40 μm quartz and aluminum oxide grains were compared. The α-irradiation TL response of aluminum oxide (330 degree C) is better than the quartz (375 degree C). (authors)

  17. Alpha particle and proton relative thermoluminescence efficiencies in LiF:Mg, Cu, P:is track structure theory up to the task?

    International Nuclear Information System (INIS)

    Horowitz, Y. S.; Siboni, D.; Oster, L.; Livingstone, J.; Guatelli, S.; Rosenfeld, A.; Emfietzoglou, D.; Bilski, P.; Obryk, B.

    2008-01-01

    Low-energy alpha particle and proton heavy charged particle (HCP) relative thermoluminescence (TL) efficiencies are calculated for the major dosimetric glow peak in LiF:Mg, Cu, P (MCP-N) in the framework of track structure theory (TST). The calculations employ previously published TRIPOS-E Monte Carlo track segment values of the radial dose in condensed phase LiF calculated at the Instituto National de Investigaciones Nucleares (Mexico) and experimentally measured normalised 60 Co gamma-induced TL dose-response functions, f(D), carried out at the Inst. of Nuclear Physics (Poland). The motivation for the calculations is to test the validity of TST in a TL system in which f(D) is not supra-linear (f(D) >1) and is not significantly dependent on photon energy contrary to the behaviour of the dose-response of composite peak 5 in the glow curve of LiF:Mg, Ti (TLD-100). The calculated HCP relative efficiencies in LiF:MCP-N are 23-87 % lower than the experimentally measured values, indicating a weakness in the major premise of TST which exclusively relates HCP effects to the radiation action of the secondary electrons liberated by the HCP slowing down. However, an analysis of the uncertainties involved in the TST calculations and experiments (i.e. experimental measurement of f(D) at high levels of dose, sample light self-absorption and accuracy in the estimation of D R, especially towards the end of the HCP track) indicate that these may be too large to enable a definite conclusion. More accurate estimation of sample light self-absorption, improved measurements of f(D) and full-track Monte Carlo calculations of D R incorporating improvements of the low-energy electron transport are indicated in order to reduce uncertainties and enable a final conclusion. (authors)

  18. Alpha particle and proton relative thermoluminescence efficiencies in LiF:Mg,Cu,P:is track structure theory up to the task?

    Science.gov (United States)

    Horowitz, Y S; Siboni, D; Oster, L; Livingstone, J; Guatelli, S; Rosenfeld, A; Emfietzoglou, D; Bilski, P; Obryk, B

    2012-07-01

    Low-energy alpha particle and proton heavy charged particle (HCP) relative thermoluminescence (TL) efficiencies are calculated for the major dosimetric glow peak in LiF:Mg,Cu,P (MCP-N) in the framework of track structure theory (TST). The calculations employ previously published TRIPOS-E Monte Carlo track segment values of the radial dose in condensed phase LiF calculated at the Instituto National de Investigaciones Nucleares (Mexico) and experimentally measured normalised (60)Co gamma-induced TL dose-response functions, f(D), carried out at the Institute of Nuclear Physics (Poland). The motivation for the calculations is to test the validity of TST in a TL system in which f(D) is not supralinear (f(D) >1) and is not significantly dependent on photon energy contrary to the behaviour of the dose-response of composite peak 5 in the glow curve of LiF:Mg,Ti (TLD-100). The calculated HCP relative efficiencies in LiF:MCP-N are 23-87% lower than the experimentally measured values, indicating a weakness in the major premise of TST which exclusively relates HCP effects to the radiation action of the secondary electrons liberated by the HCP slowing down. However, an analysis of the uncertainties involved in the TST calculations and experiments (i.e. experimental measurement of f(D) at high levels of dose, sample light self-absorption and accuracy in the estimation of D(r), especially towards the end of the HCP track) indicate that these may be too large to enable a definite conclusion. More accurate estimation of sample light self-absorption, improved measurements of f(D) and full-track Monte Carlo calculations of D(r) incorporating improvements of the low-energy electron transport are indicated in order to reduce uncertainties and enable a final conclusion.

  19. Development of tailor-made silica fibres for TL dosimetry

    International Nuclear Information System (INIS)

    Bradley, D.A.; Abdul Sani, Siti F.; Alalawi, Amani I.; Jafari, S.M.; Noor, Noramaliza M.; Hairul Azhar, A.R.; Mahdiraji, Ghafour Amouzad; Tamchek, Nizam; Ghosh, S.; Paul, M.C.; Alzimami, Khalid S.; Nisbet, A.; Maah, M.J.

    2014-01-01

    The Ge dopant in commercially available silica optical fibres gives rise to appreciable thermoluminscence (TL), weight-for-weight offering sensitivity to MV X-rays several times that of the LiF dosimeter TLD100. The response of these fibres to UV radiation, X-rays, electrons, protons, neutrons and alpha particles, with doses from a fraction of 1 Gy up to 10 kGy, have stimulated further investigation of the magnitude of the TL signal for intrinsic and doped SiO 2 fibres. We represent a consortium effort between Malaysian partners and the University of Surrey, aimed at production of silica fibres with specific TL dosimetry applications, utilizing modified chemical vapour deposition (MCVD) doped silica–glass production and fibre-pulling facilities. The work is informed by defect and dopant concentration and various production dependences including pulling parameters such as temperature, speed and tension; the fibres also provide for spatial resolutions down to <10 µm, confronting many limitations faced in use of conventional (TL) dosimetry. Early results are shown for high spatial resolution (∼0.1 mm) single-core Ge-doped TL sensors, suited to radiotherapy applications. Preliminary results are also shown for undoped flat optical fibres of mm dimensions and Ge-B doped flat optical fibres of sub-mm dimensions, with potential for measurement of doses in medical diagnostic applications. - Highlights: • Optical fibres tailor-made for TL dosimetry. • Sensitive to diagnostic as well as therapy doses in medicine. • Preform and fibre pulling facilities. • Relative TL and EPR measurements

  20. Measurements of environmental gamma-ray spectra using a multi-element TL dosemeter

    International Nuclear Information System (INIS)

    Furuta, Sadaaki; Boetter-Jensen, L.; Nielsen, S.P.

    1986-12-01

    A method to estimate the energy distribution and dose of environmental gamma radiation was developed using a multielement TL dosemeter. Experimentally obtained energy responses from a multi-element TL dosemeter with different kinds of filters were used to calculate the energy distribution and related dose by the SAND-II computer code. The code was originally developed to estimate the neutron flux using a multiple foil activation method. Measurements were made at several locations with the multi-element TL dosemeter and comparisons were made with results from a NaI(Tl) scintillation detector and a high-pressure ionization chamber. (author)

  1. NaI(Tl) response functions

    Energy Technology Data Exchange (ETDEWEB)

    Vega C, H. R.; Ortiz R, J. M. [Universidad Autonoma de Zacatecas, Unidad Academica de Estudios Nucleares, Cipres No. 10, Fracc. La Penuela, 98068 Zacatecas, Zac. (Mexico); Benites R, J. L. [Centro Estatal de Cancerologia de Nayarit, Calz. de la Cruz 118 Sur, Tepic, Nayarit (Mexico); De Leon M, H. A., E-mail: fermineutron@yahoo.com.mx [Instituto Tecnologico de Aguascalientes, Av. Adolfo Lopez Mateos 1801 Ote., 20155 Aguascalientes, Ags. (Mexico)

    2015-09-15

    The response functions of a NaI(Tl) detector have been estimated using Monte Carlo methods. Response functions were calculated for monoenergetic photon sources (0.05 to 3 MeV). Responses were calculated for point-like sources and for sources distributed in Portland cement cylinders. The responses were used to calculate the efficiency functions in term of photon energy. Commonly, sources used for calibration are point-like, and eventually sources to be measured have different features. In order to use the calibrated sources corrections due to solid angle, self-absorption and scattering, must be carried out. However, some of these corrections are not easy to perform. In this work, the calculated responses were used to estimate the detector efficiency of point-like sources, and sources distributed in Portland type cement. Samples of Portland paste were prepared and were exposed to photoneutrons produced by a 15 MV linac. Some of the elements in the cement were activated producing γ-emitting radionuclides that were measured with a NaI(Tl) gamma-ray spectrometer, that was calibrated with point-like sources. In order to determine the specific activity in the induced radioisotopes calculated efficiencies were used to make corrections due to the differences between the solid angle, photon absorption and photon scattering in the point-like calibration sources and the sources distributed in cement. During the interaction between photoneutrons and the cement samples three radioisotopes were induced: {sup 56}Mn, {sup 24}Na, and {sup 28}Al. (Author)

  2. How Experienced SoTL Researchers Develop the Credibility of Their Work

    Directory of Open Access Journals (Sweden)

    Jennie Billot

    2017-03-01

    Full Text Available Teaching and learning research in higher education, often referred to as the Scholarship of Teaching and Learning (SoTL, is still relatively novel in many academic contexts compared to the mainstay of disciplinary research. One indication of this is the challenges those who engage in SoTL report in terms of how this work is valued or considered credible amongst disciplinary colleagues and in the face of institutional policies and practices. This paper moves beyond the literature that describes these specific challenges to investigate how 23 experienced SoTL researchers from five different countries understood the notion of credibility in relationship to their SoTL research and how they went about developing credibility for their work. Semi-structured interviews were facilitated and analyzed using inductive analysis. Findings indicate that notions of credibility encompassed putting SoTL research into action and building capacity and community around research findings, as well as gaining external validation through traditional indicators such as publishing. SoTL researchers reported a variety of strategies and approaches they were using, both formal and informal, to develop credibility for their work. The direct focus of this paper on credibility of SoTL work as perceived by experienced SoTL researchers, and how they go about developing credibility, is a distinct contribution to the discussions about the valuing of SoTL work.

  3. X-ray photoemission studies of Zn doped Cu1-xTl xBa2Ca2Cu 3-yZn yO10-δ (y = 0, 2.65) superconductors

    International Nuclear Information System (INIS)

    Khan, Nawazish A.; Mumtaz, M.; Ahadian, M.M.; Iraji-zad, Azam

    2007-01-01

    The X-ray photoemission (XPS) measurements of Cu 1-x Tl x Ba 2 Ca 2 Cu 3-y Zn y O 10-δ (y = 0, 2.65) superconductors have been performed and compared. These studies revealed that the charge state of thallium in the Cu 0.5 Tl 0.5 Ba 2 O 4-δ charge reservoir layer in Zn doped samples is Tl 1+ , while it is a mix of Tl 1+ and Tl 2+ in Zn free samples. The binding energy of Ba atoms in the Zn doped samples is shifted to higher energy, which when considered along with the presence of Tl 1+ suggested that it more efficiently directed the carriers to ZnO 2 and CuO 2 planes. The evidence of improved inter-plane coupling witnessed in X-ray diffraction is also confirmed by XPS measurements of Ca atoms in the Zn doped samples. The shift of the valance band spectrum in these Zn doped samples to higher energies suggested that the electrons at the top edge of the valance band were tied to a higher binding energy (relative to samples without Zn doping), which most likely resulted in a much lower energy state of the system in the superconducting state. The stronger superconducting state arising out of these effects is witnessed in the form of increased T c (R 0), J c and the extent of diamagnetism in the final compound

  4. M1 transitions between superdeformed states in 195Tl

    International Nuclear Information System (INIS)

    Zheng Xing; Xingqu Chen; Xiaochun Wang

    1996-01-01

    Using a triaxial-particle-rotor model, the quadrupole and dipole transition energies, kinematic and dynamic moments of inertia, electromagnetic transition probabilities and the relative intensity of the E2 γ-transitions are calculated for superdeformed bands in 195 Tl. A strong perturbation effect of rotation on transition energies and M1 and E2 transitions of superdeformed states is investigated. The total M1 transitions, enhanced by internal conversion, are expected to compete strongly with the E2 γ-ray at low spins in the superdeformed 195 Tl nucleus. (author)

  5. Comparing EU hospital efficiency using diagnosis-related groups

    NARCIS (Netherlands)

    Rhodes, G.; Wiley, M.; Tomas, R.; Casas, M.; Leidl, R.

    1997-01-01

    This article considers the feasibility of comparing the differences in efficiency and price in the provision of hospital products defined on the basis of diagnosis-related groups (DRGs). Two measures of resource use are compared, the length of stay and the administrative price, both independently

  6. The Relative Efficiency of Charter Schools: A Cost Frontier Approach

    Science.gov (United States)

    Gronberg, Timothy J.; Jansen, Dennis W.; Taylor, Lori L.

    2012-01-01

    Charters represent an expansion of public school choice, offering free, publicly funded educational alternatives to traditional public schools. One relatively unexplored research question concerning charter schools asks whether charter schools are more efficient suppliers of educational services than are traditional public schools. The potential…

  7. Converting Hg-1212 to Tl-2212 via Tl-Hg cation exchange in combination with Tl cation intercalation

    International Nuclear Information System (INIS)

    Zhao Hua; Wu, Judy Z

    2007-01-01

    In a cation exchange process developed recently for epitaxy of HgBa 2 CaCu 2 O 6 (Hg-1212) thin films, TlBa 2 CaCu 2 O 7 (Tl-1212) or Tl 2 Ba 2 CaCu 2 O 9 (Tl-2212) precursor films were employed as the precursor matrices and Hg-1212 was obtained by replacing Tl cations on the precursor lattice with Hg cations. The reversibility of the cation exchange dictates directly the underlying mechanism. Following our recent success in demonstrating a complete reversibility within '1212' structure, we show the conversion from Hg-1212 to Tl-2212 can be achieved via two steps: conversion from Hg-1212 to Tl-1212 followed by Tl intercalation to form double Tl-O plans in each unit cell. The demonstrated reversibility of the cation exchange process has confirmed the process is a thermal perturbation of weakly bonded cations on the lattice and the direction of the process is determined by the population ratio between the replacing cations and that to be replaced

  8. Superconducting transition in TlBiTe/sub 2/ and TlTe compounds

    Energy Technology Data Exchange (ETDEWEB)

    Kantser, V G; Popovich, N S; Sidorenko, A S

    1985-10-01

    On the basis of zone structure calculation for TlBiTe/sub 2/ and TlTe it is found that TlBiTe/sub 2/ is a narrow-gap semiconductor and TlTe is a p-metal. At Tsub(c)=0.19 K TlTe is found to experience the superconducting transition. In TlBiTe/sub 2/ superconductivity is not observed to occur up to 0.05 K, since there is a possibility of occupying the high density of states zones because they are remote from actual ones. The earlier discovered superconducting transition in TlBiTe/sub 2/ is inherent in the alien phase of TlTe.

  9. Myasthenia Gravis Impairment Index: Responsiveness, meaningful change, and relative efficiency.

    Science.gov (United States)

    Barnett, Carolina; Bril, Vera; Kapral, Moira; Kulkarni, Abhaya V; Davis, Aileen M

    2017-12-05

    To study responsiveness and meaningful change of the Myasthenia Gravis Impairment Index (MGII) and its relative efficiency compared to other measures. We enrolled 95 patients receiving prednisone, IV immunoglobulin (IVIg), or plasma exchange (PLEX) and 54 controls. Patients were assessed with the MGII and other measures-including the Quantitative Myasthenia Gravis Score, Myasthenia Gravis Composite, and Myasthenia Gravis Activities of Daily Living-at baseline and 3-4 weeks after treatment. Statistical markers of responsiveness included between-groups and within-group differences, and we estimated the relative efficiency of the MGII compared to other measures. Patient-meaningful change was assessed with an anchor-based method, using the patient's impression of change. We determined the minimal detectable change (MDC) and the minimal important difference (MID) at the group and individual level. Treated patients had a higher change in MGII scores than controls (analysis of covariance p 1 favoring the MGII. The MGII demonstrated responsiveness to prednisone, IVIg, and PLEX in patients with myasthenia. There is a differential response in ocular and generalized symptoms to type of therapy. The MGII has higher relative efficiency than comparison measures and is viable for use in clinical trials. Copyright © 2017 The Author(s). Published by Wolters Kluwer Health, Inc. on behalf of the American Academy of Neurology.

  10. Preparation of 199Tl using the electroplating gold targets on the internal target installation of cyclotron

    International Nuclear Information System (INIS)

    Zhou Dehai; Xie Degao; Chao Yangshu; Liao Fuquan; Zhang Youfa; Wang Zefu

    1992-01-01

    The separative conditions of 199 Tl from Cu, Au and Ga by reaction 197 Au(α, 2n) 199 Tl on the internal target installation of cyclotron is studied. The α-particle energy is selected in the range of 24-15 MeV. The cumulative current intensities of such α-particle beams bombarding the gold target at 150-200 μA are 1200 μA · h and 1500 μA · h respectively. The radiochemical separation of 199 Tl is carried out with isopropyl ether extraction and anions exchange from the irradiated gold targets. The radioactivities of 199 Tl and 200 Tl are 2.3 x 10 5 Bq and 7.1 x 10 2 Bq, and 200 Tl makes up 0.29% of the total radioactivity. The impurity elements contained 1 ml of 199 TlCl injection solution are Au 199 TlCl has been used in clinical experiments in vivo and relatively good results have been obtained

  11. Sample dependent correlation between TL and LM-OSL in Al2O3:C

    International Nuclear Information System (INIS)

    Dallas, G.I.; Polymeris, G.S.; Stefanaki, E.C.; Afouxenidis, D.; Tsirliganis, N.C.; Kitis, G.

    2008-01-01

    Al 2 O 3 :C single crystals are known to exhibit different, sample dependent, glow-curve shapes. The relation between the Thermoluminescence (TL) traps and the linear modulated optically stimulation luminescence (LM-OSL) traps is of high importance. In the present work a correlation study is attempted using 23 single crystals with dimensions between 400 and 500μm. The correlation study involved two steps. In the first step, both TL glow curves and LM-OSL decay curves are deconvoluted and a one-to-one correlation between TL peaks and LM-OSL components is attempted. In the second step the TL glow-curves are corrected for thermal quenching, the corrected curves are deconvoluted and a new correlation between TL and LM-OSL individual components is performed

  12. An Efficient Inductive Genetic Learning Algorithm for Fuzzy Relational Rules

    Directory of Open Access Journals (Sweden)

    Antonio

    2012-04-01

    Full Text Available Fuzzy modelling research has traditionally focused on certain types of fuzzy rules. However, the use of alternative rule models could improve the ability of fuzzy systems to represent a specific problem. In this proposal, an extended fuzzy rule model, that can include relations between variables in the antecedent of rules is presented. Furthermore, a learning algorithm based on the iterative genetic approach which is able to represent the knowledge using this model is proposed as well. On the other hand, potential relations among initial variables imply an exponential growth in the feasible rule search space. Consequently, two filters for detecting relevant potential relations are added to the learning algorithm. These filters allows to decrease the search space complexity and increase the algorithm efficiency. Finally, we also present an experimental study to demonstrate the benefits of using fuzzy relational rules.

  13. Studies on the tumor and organ affinity of /sup 201/Tl

    Energy Technology Data Exchange (ETDEWEB)

    Mori, H; Ando, I; Takeuchi, T [Kanazawa Univ. (Japan). School of Medicine; Ando, A; Hiraki, T

    1980-01-01

    In order to evaluate the tumor and organ affinity of /sup 201/Tl, using the Yoshida sarcoma bearing rats, the distribution of /sup 201/Tl/sup +/ in tissues and tumor was examined and compared to /sup 22/Na/sup +/, /sup 42/K/sup +/, /sup 86/Rb/sup +/, /sup 134/Cs/sup +/, and /sup 67/Ga-citrate. /sup 201/Tl/sup +/ showed almost same organ accumulation and kinetics as /sup 42/K/sup +/, /sup 86/Rb/sup +/, /sup 134/Cs, whereas /sup 201/Tl/sup +/ and /sup 22/Na/sup +/ had completely different organ distribution. These results suggest that organ affinity of /sup 201/Tl/sup +/ might be related to active transport, namely Na/sup +/-K/sup +/-ATPase pump mechanism as well as blood flow. However, it appeared to be taken into account the other factors such as different accumulation and clearance rate due to different substrates of organs. Kidney accumulation rate of /sup 201/Tl/sup +/ was much higher than /sup 42/K/sup +/, /sup 86/Rb/sup +/, /sup 134/Cs/sup +/ and about 10 times as /sup 42/K/sup +/. Macroautoradiograms of rat kidneys showed that /sup 201/Tl/sup +/ exhibited an initial high accumulation in the cortex and appeared in the outer cortex, as the cortex cleared of radioactivity. /sup 201/Tl might be interchangeable with K/sup +/ in the tubular system, reabsorbed with more affinity and cleared more slowly than K/sup +/. The tumor accumulation /sup 201/Tl/sup +/ might be related to Na/sup +/-K/sup +/-ATPase pump mechanism as well as other organs. However, in terms of tumor accumulation and concentration ratio to other organs, /sup 201/Tl/sup +/ was inferior to /sup 67/Ga-citrate, although the tumor to blood ratio was identical to that of /sup 67/Ga-citrate. Since /sup 201/Tl/sup + + +/ showed almost same distribution as /sup 201/Tl/sup +/, /sup 201/Tl/sup + + +/ might change into /sup 201/Tl/sup +/ in vivo.

  14. Quaternary chalcogenides of the IVa metals with layered structures: preparation and crystal structures of TlCuTIVQ3 (T=Zr, Hf; Q=S, Se) and their relation to the Re3B structure type

    International Nuclear Information System (INIS)

    Klepp, K.O.; Gurtner, D.

    1996-01-01

    The new compounds TlCuT IV Q 3 (T = Zr, Hf; Q = S, Se) were prepared by reacting intimate mixtures of Tl 2 S or TlSe with stoichiometric amounts of the corresponding Group IV metal, Cu and the corresponding chalcogen at 870 . The four compounds are isostructural and crystallize in Cmcm, Z = 4 with a 3.726(4) A, b = 13.987(9) A, c = 9.783(4) A for TlCuZrS 3 ; a = 3.847(1) A, b 14.381(6) A, c = 10.150(1) A for TlCuZrSe 3 ; a = 3.694(1) A, b = 14.030(3) A, c = 9.750(3) A for TlCuHfS 3 ; and a = 3.831(1) A, b = 14.409(9) A, c = 10.124(2) A for TlCuHfSe 3 . Their crystal structures were determined from single crystal diffractometer data (Mo Kα radiation, ambient temperature) and refined to conventional R values of 0.016, 0.040, 0.019 and 0.031 respectively. An outstanding feature of their crystal structures is the formation of infinite anionic layers, 2 ∞ -[CuT IV Q 3 ] - parallel to (010), which are separated by Tl + cations. These layers are built up by edge sharing TQ 6 octahedra and distorted CuQ 4 tetrahedra. Average T-Q distances are anti d(Zr-S) = 2.586(1) A, anti d(Zr-Se) = 2.707(1) A, anti d(Hf-S) = 2.569(2) A and anti d(Hf-Se) = 2.694(1) A. Cu-chalcogen distances are anti d(Cu-S) = 2.318(2) A and anti d(Cu-Se) = 2.432(3) A respectively. The thallium ions are in bicapped trigonal prismatic chalcogen coordinations. The atomic arrangement corresponds to that of KCuZrS 3 ; based on the thallium-chalcogen partial structure it can be regarded as a filled variant of an anti-Re 3 B structure type. (orig.)

  15. Prolate yrast cascade in 183Tl

    International Nuclear Information System (INIS)

    Reviol, W.; Carpenter, M. P.; Janssens, R. V. F.; Jenkins, D.; Toth, K. S.; Bingham, C. R.; Riedinger, L. L.; Weintraub, W.; Cizewski, J. A.; Lauritsen, T.

    2000-01-01

    The yrast sequence in 183 Tl has been studied for the first time in recoil-mass selected γ-ray spectroscopic measurements. A rotational-like cascade of seven transitions is established down to the band head with probable spin and parity (13/2 + ). Unlike in the adjacent odd-mass Tl nuclei, prompt γ decay from the yrast band to a lower lying weakly deformed (oblate) structure is not observed. These features are consistent with the predicted drop of the prolate band head in 183 Tl compared to 185 Tl. The implications for the prolate energy minimum in odd-mass Tl nuclei at the neutron i 13/2 midshell (N=103) are discussed. (c) 2000 The American Physical Society

  16. International Congress on Energy Efficiency and Energy Related Materials

    CERN Document Server

    Bahsi, Zehra; Ozer, Mehmet; ENEFM2013

    2014-01-01

    The International Congress on Energy Efficiency and Energy Related Materials (ENEFM2013) was held on 9-12 October, 2013. This three-day congress focused on the latest developments of sustainable energy technologies, materials for sustainable energy applications and environmental & economic perspectives of energy. These proceedings include 63 peer reviewed technical papers, submitted from leading academic and research institutions from over 23 countries, representing some of the most cutting edge research available. The papers included were presented at the congress in the following sessions: General Issues Wind Energy Solar Energy Nuclear Energy Biofuels and Bioenergy Energy Storage Energy Conservation and Efficiency Energy in Buildings   Economical and Environmental Issues Environment Energy Requirements Economic Development   Materials for Sustainable Energy Hydrogen Production and Storage Photovoltaic Cells Thermionic Converters Batteries and Superconductors Phase Change Materials Fuel Cells Supercon...

  17. 201Tl in myocardial diagnosis: studies on the influence of dipyridamole, dobutamine ergometer exercise and background subtraction on the 201Tl myocadial scintiscam

    International Nuclear Information System (INIS)

    Seiderer, M.

    1979-01-01

    Changes in 201 Tl myocardial scintiscans upon administration of dipyridamole or dobutamine and upon ergometer exercise relative to scintiscans at rest were investigated as well as the influence of myocardial background subtraction on scintiscan quality and information. A total of 90 201 Tl examinations were carried out in 59 patients. 18 patients had no myocardial disease, 30 patients had a coronary disease, 5 patients suffered from cardiomyopathy and 6 from left ventricular hypertrophy. The findings are discussed in detail. (orig.) [de

  18. Clinical use of 201Tl myocardial scintigraphy

    International Nuclear Information System (INIS)

    Senda, Kohei; Imaeda, Takeyoshi; Kato, Toshimitsu; Asada, Shuichi; Doi, Hidetaka

    1977-01-01

    Myocardial imaging with 201 Tl and scinticamera was studied experimentally using specially designed phantoms and clinically in 23 patients with myocardial infarction or other heart disease. In the phantom experiment, quality of image, accumulative count rate, and detectability of the defect were compared to obtain the best technique for their detection, using four different collimators, i.e., converging, pin-hole, 4000-hole, and 140 keV high-resolution, at two photopeak levels of 201 Tl of 75 and 167 keV, and combining a radiation absorber. In patient examination, myocardial images taken at different periods after injection, different detecting conditions of the scinticamera, and various detecting projections were compared. Images of the converging collimator at the 75 keV photopeak revealed considerably higher accumulative counts and relatively higher quality than those of other detecting conditions. It was necessary to take as many images as possible in various projections, in order to detect the location and size of the myocardial ischemic lesion because the lesion was demonstrated as a clear defect only in profile. It became evident that images taken between about 25 and 90 min delineated the myocardium more clearly than those taken in other periods. Normal images taken in 8 patients without ischemic heart disease appeared in the shape of a doughnut of horseshoe, demonstrating mainly the left venticular myocardium. The image was faint in the region of the aortic or mitral valve and thin in the region of the apical wall. A faint image of the right ventricular myocardium was sometimes seen. In 3 patients with valvular heart disease, findings suggested changes in the thickness of myocardium and the distribution of coronary blood flow. In 11 of 12 patients with old myocardial infarction, the location and size of the lesion was detected. (Evans, J.)

  19. Gamma spectra analysis from a NaI(Tl) scintillation detector using a micro-computer

    International Nuclear Information System (INIS)

    Levinson, S.

    1990-01-01

    A software package of programs was devloped for qualitative and quantitative evaluation of gamma ray spectra obtained from a NaI(Tl) scintilation counter, by means of a micro-computer. The programs can easily be transformed for use with a Ge(Li) detector. The various algorithms enable automatic analyzing of a spectrum and also interactive or manual mode. The graphic programs display the measured spectrum as well as spectra of standard radionuclides which helps in the determination of peaks and related radionuclides in the spectrum. The peak search is carried out on a smoothed spectrum and is done by checking the behaviour of the second and third derivatives. The algorithm solves the problem of overlapping peaks and performs gaussian fitting, if necessary. Determination of the various radionuclides in the spectrum is done by linear minimum least squares techniques. Overall analysis of the radionuclides activities in the spectrum is obtained for samples of various counting geometries. In addition, a model was developed for efficiency calibration of flat 3X3 inch NaI(Tl) detectors for different samples measured in various counting geometries. It is based on point source experimental efficiency curve fitting. (author)

  20. Coping efficiently with now-relative medical data.

    Science.gov (United States)

    Stantic, Bela; Terenziani, Paolo; Sattar, Abdul

    2008-11-06

    In Medical Informatics, there is an increasing awareness that temporal information plays a crucial role, so that suitable database approaches are needed to store and support it. Specifically, most clinical data are intrinsically temporal, and a relevant part of them are now-relative (i.e., they are valid at the current time). Even if previous studies indicate that the treatment of now-relative data has a crucial impact on efficiency, current approaches have several limitations. In this paper we propose a novel approach, which is based on a new representation of now, and on query transformations. We also experimentally demonstrate that our approach outperforms its best competitors in the literature to the extent of a factor of more than ten, both in number of disk accesses and of CPU usage.

  1. Enhanced thermoelectric figure of merit in strained Tl-doped Bi2Se3

    KAUST Repository

    Saeed, Y.

    2014-07-21

    We explain recent experimental findings on Tl-doped Bi2Se3 by determining the electronic and transport properties by first-principles calculations and semi-classical Boltzmann theory. Though Tl-doping introduces a momentum-dependent spin-orbit splitting, the effective mass of the carriers is essentially not modified, while the band gap is reduced. Tl is found to be exceptional in this respect as other dopants modify the dispersion, which compromises thermoelectricity. Moreover, we demonstrate that only after Tl-doping strain becomes an efficient tool for enhancing the thermoelectric performance. A high figure of merit of 0.86 is obtained for strong p-doping (7 × 10^20 cm^(−3), maximal power factor) at 500 K under 2% tensile strain.

  2. TL and LOE dosimetric evaluation of diamond films exposed to beta and ultraviolet radiation

    International Nuclear Information System (INIS)

    Preciado F, S.; Melendrez, R.; Chernov, V.; Barboza F, M.; Schreck, M.; Cruz Z, E.

    2005-01-01

    The diamond possesses a privileged position regarding other materials of great technological importance. Their applications go from the optics, microelectronics, metals industry, medicine and of course as dosemeter, in the registration and detection of ionizing and non ionizing radiation. In this work the results of TL/LOE obtained in two samples of diamond of 10 μm thickness grown by the chemical vapor deposition method (CVD) assisted by microwave plasma. The films were deposited in a silicon substrate (001) starting from a mixture of gases composed of CH 4 /H 2 and 750 ppm of molecular nitrogen as dopant. The samples were exposed to beta radiation (Sr 90 / Y 90 ) and ultraviolet, being stimulated later on thermal (TL) and optically (LOE) to evaluate their dosimetric properties. The sample without doping presented high response TL/LOE to the ultraviolet and beta radiation. The TL glow curve of the sample without doping showed two TL peaks with second order kinetics in the range of 520 to 550 K, besides a peak with first order kinetics of more intensity around 607 K. The TL efficiency of the non doped sample is bigger than the doped with nitrogen; however the LOE efficiency is similar in both samples. The results indicate that the CVD diamond possesses excellent perspectives for dosimetric applications, with special importance in radiotherapy due to it is biologically compatible with the human tissue. (Author)

  3. Chemical Bonding in Tl Cuprates Studied by X-Ray Photoemission

    Energy Technology Data Exchange (ETDEWEB)

    Lao, J.Y.; Overmyer, D.L.; Ren, Z.F.; Siegal, M.P.; Vasquez, R.P.; Wang, J.H.

    1999-04-05

    Epitaxial thin films of the Tl cuprate superconductors Tl{sub 2}Ba{sub 2}CaCu{sub 2}O{sub 8}, Tl{sub 2}Ba{sub 2}Ca{sub 2}Cu{sub 3}O{sub 10}, and TL{sub 0.78}Bi{sub 0.22}Ba{sub 0.4}Sr{sub 1.6}Ca{sub 2}Cu{sub 3}O{sub 9{minus}{delta}} are studied with x-ray photoemission spectroscopy. These data, together with previous measurements in this lab of Tl{sub 2}Ba{sub 2}CuO{sub 6+{delta}} and TlBa{sub 2}CaCu{sub 2}O{sub 7{minus}{delta}}, comprise a comprehensive data set for a comparative study of Tl cuprates with a range of chemical and electronic properties. In the Cu 2p spectra, a larger energy separation between the satellite and main peaks (E{sub s}-E{sub m}) and a lower intensity ratio (I{sub s}/I{sub m}) are found to correlate with higher values of T{sub c}. Analysis of these spectra within a simple configuration interaction model suggests that higher values of T{sub c} are related to low values of the O 2p {r_arrow} Cu 3d charge transfer energy. In the O 1s region, a smaller bond length between Ba and Cu-O planar oxygen is found to correlate with a lower binding energy for the signal associated with Cu-O bonding, most likely resulting from the increased polarization screening by Ba{sup 2+} ions. For samples near optimum doping, maximum T{sub c} is observed to occur when the Tl 4f{sub 7/2} binding energy is near 117.9 eV, which is near the middle of the range of values observed for Tl cuprates. Higher Tl 4f{sub 7/2} binding energies, corresponding to formal oxidation states nearer Tl{sup 1+}, are also found to correlate with longer bond lengths between Ba and Tl-O planar oxygen, and with higher binding energies of the O 1s signal associated with Tl-O bonding.

  4. Chemical bonding in Tl cuprates studied by x-ray photoemission

    Energy Technology Data Exchange (ETDEWEB)

    Vasquez, R.P. [Center for Space Microelectronics Technology, Jet Propulsion Laboratory, California Institute of Technology, Pasadena, California 91109-8099 (United States); Siegal, M.P.; Overmyer, D.L. [Sandia National Laboratories, Albuquerque, New Mexico 87185-1421 (United States); Ren, Z.F.; Lao, J.Y.; Wang, J.H. [Materials Synthesis Laboratory, Department of Chemistry, State University of New York, Buffalo, New York 14260-3000 (United States)

    1999-08-01

    Epitaxial thin films of the Tl cuprate superconductors Tl{sub 2}Ba{sub 2}CaCu{sub 2}O{sub 8}, Tl{sub 2}Ba{sub 2}Ca{sub 2}Cu{sub 3}O{sub 10}, and Tl{sub 0.78}Bi{sub 0.22}Ba{sub 0.4}Sr{sub 1.6}Ca{sub 2}Cu{sub 3}O{sub 9{minus}{delta}} are studied with x-ray photoemission spectroscopy. These data, together with previous measurements in this lab of Tl{sub 2}Ba{sub 2}CuO{sub 6+{delta}} and TlBa{sub 2}CaCu{sub 2}O{sub 7{minus}{delta}}, comprise a comprehensive data set for a comparative study of Tl cuprates with a range of chemical and electronic properties. In the Cu 2p spectra, a larger energy separation between the satellite and main peaks (E{sub s}{minus}E{sub m}) and a lower intensity ratio (I{sub s}/I{sub m}) are found to correlate with higher values of T{sub c}. Analysis of these spectra within a simple configuration interaction model suggests that higher values of T{sub c} are related to low values of the O&hthinsp;2p{r_arrow}Cu&hthinsp;3d charge transfer energy. In the O&hthinsp;1s region, a smaller bond length between Ba and Cu-O planar oxygen is found to correlate with a lower binding energy for the signal associated with Cu-O bonding, most likely resulting from the increased polarization screening by Ba{sup 2+} ions. For samples near optimum doping, maximum T{sub c} is observed to occur when the Tl 4f{sub 7/2} binding energy is near 117.9 eV, which is near the middle of the range of values observed for Tl cuprates. Higher Tl&hthinsp;4f{sub 7/2} binding energies, corresponding to formal oxidation states nearer Tl{sup 1+}, are also found to correlate with longer bond lengths between Ba and Tl-O planar oxygen, and with higher binding energies of the O&hthinsp;1s signal associated with Tl-O bonding. {copyright} {ital 1999} {ital The American Physical Society}

  5. RDM lifetime measurements in 187Tl

    International Nuclear Information System (INIS)

    Chamoli, S.K.; Joshi, P.; Kumar, A.; Govil, I.M.; Mukherjee, G.; Singh, R.P.; Muralithar, S.; Bhowmik, R.K.

    2003-01-01

    The present work is an attempt to study the shape changes in 187 Tl through a measurement of electromagnetic transition probabilities of the high spin states. The Doppler shifted recoil distance technique was used to measure the lifetimes

  6. Disquisition and technical alteration about TL apparatus

    International Nuclear Information System (INIS)

    Wang Guangxiang; Li Mingliang

    2002-01-01

    The author simply introduces the disadvantage of TL apparatus controlled by single chip. The project uses the PC computer to replace single chip control. So it must be changed the interface and made up a software with Chinese

  7. Preliminary results on TL and OSL aluminium oxide dosimeters developed at IPEN

    Energy Technology Data Exchange (ETDEWEB)

    Fukumori, David T.; Yoshito, Walter K.; Ussui, Valter; Lazar, Dolores R.R.; Campos, Leticia L., E-mail: fukumori@ipen.b [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2011-07-01

    The aluminum oxide composes the modern TL and OSL radiation dosimeters. TL and OSL phenomena are related to chemical elements in the crystalline structure of {alpha}-Al{sub 2}O{sub 3}. The aim of this work was to develop materials based on aluminum oxide for use in TL and OSL dosimetry. The studies included the dosimetric properties of alumina samples obtained by electro fusion, adsorption and coprecipitation. Electro fused alumina commercially available as abrasive particles was used to produce the pellets by glass sintering. Adsorption and coprecipitation were the methods used to insert metal ions to alumina. The best results were achieved with electro fused alumina and Tm{sup 3+} doped Al{sub 2}O{sub 3} pellets. The electro fused alumina-glass pellets show TL and OSL signals and the TL curve has two peaks. Its minimum detectable radiation dose is 7.2 mGy and the linearity of TL response as function of dose is up to about 800 mGy. The {alpha}-Al{sub 2}O{sub 3}:Tm pellets produced by sintering at 1550 deg C presented a meaningful TL glow curve so that it is worth studying their properties and viability of use in dosimetry. (author)

  8. Significance of Tl-201 redistribution on infarcted region assessed by coronary sinus flow and lactate metabolism

    International Nuclear Information System (INIS)

    Mori, Takao; Yamabe, Hiroshi; Suda, Kenichirou; Ohnishi, Masataka; Shiotani, Hideyuki; Kurimoto, Yasuyuki; Kobayashi, Katsuya; Maeda, Kazumi; Fukuzaki, Hisashi

    1987-01-01

    To clarify the significance of Tl-201 redistribution on infarcted regions, coronary sinus and great cardiac vein flow response and lactate metabolism assessed by Webster catheter on 14 infarcted regions after dipyridamole administration were compared with Tl-201 redistribution phenomenon. The regional coronary flow response and lactate extraction ratio in 11 regions with Tl-201 redistribution were lower than those in 3 regions without Tl-201 redistribution. Only 5 regions in 11 with Tl-201 redistribution showed lactate production. The coronary flow response in 5 regions with lactate production was not different from those in 6 without lactate production (1.16 ± 0.89 vs. 1.47 ± 0.67; n.s.). The degree of Tl-201 redistribution assessed by relative activity was not different between regions with and without lactate production. The left ventricular end-diastolic pressure elevated in 5 regions with lactate production (17.8 ± 5.4 mmHg to 29.6 ± 4.9 mmHg; p < 0.05), but didn't in 6 regions without lactate production. Five regions with lactate production contained 4 hypokinetic regions, on the other hand 6 regions without lactate production contained only 3 hypokinetic regions. In conclusion, Tl-201 redistribution on infarcted region revealed not only ischemia but also decreased coronary flow response without lactate production and/or left ventricular dysfunction. (author)

  9. Progress and problems with automated TL dating

    International Nuclear Information System (INIS)

    McKerrell, H.; Mejdahl, V.

    1981-01-01

    A number of basic problems connected with the measurement of beta and gamma dose-rates are discussed, and the possibility of using low-temperature peaks in quartz and feldspar for dose-rate measurements is examined. Preliminary results of TL measurements on individual grains of quartz and feldspar are presented. A TL dating method based on the difference in the archaeological dose received by potassium feldspar and quartz grains is proposed. (author)

  10. The relation between energy efficiency and general objectives

    International Nuclear Information System (INIS)

    Holmberg, John; Naessen, Jonas; Sprei, Frances

    2006-09-01

    Three overall objectives for energy efficiency programs are discussed: Reduction of negative externalities, esp. climatic change; Phase-out of nuclear power while limiting electricity imports; and creating welfare gains by correcting market failures of energy efficiency programs (rebound effects)

  11. The use of thallium diethyldithiocarbamate for mapping CNS potassium metabolism and neuronal activity: Tl+ -redistribution, Tl+ -kinetics and Tl+ -equilibrium distribution.

    Science.gov (United States)

    Wanger, Tim; Scheich, Henning; Ohl, Frank W; Goldschmidt, Jürgen

    2012-07-01

    The potassium (K(+)) analogue thallium (Tl(+)) can be used as a tracer for mapping neuronal activity. However, because of the poor blood-brain barrier (BBB) K(+) -permeability, only minute amounts of Tl(+) enter the brain after systemic injection of Tl(+) -salts like thallium acetate (TlAc). We have recently shown that it is possible to overcome this limitation by injecting animals with the lipophilic chelate complex thallium diethyldithiocarbamate (TlDDC), that crosses the BBB and releases Tl(+) prior to neuronal or glial uptake. TlDDC can thus be used for mapping CNS K(+) metabolism and neuronal activity. Here, we analyze Tl(+) -kinetics in the rodent brain both experimentally and using simple mathematical models. We systemically injected animals either with TlAc or with TlDDC. Using an autometallographic method we mapped the brain Tl(+) -distribution at various time points after injection. We show that the patterns and kinetics of Tl(+) -redistribution in the brain are essentially the same irrespective of whether animals have been injected with TlAc or TlDDC. Data from modeling and experiments indicate that transmembrane Tl(+) -fluxes in cells within the CNS in vivo equilibrate at similar rates as K(+) -fluxes in vitro. This equilibration is much faster than and largely independent of the equilibration of Tl(+) -fluxes across the BBB. The study provides further proof-of-concept for the use of TlDDC for mapping neuronal activity and CNS K(+) -metabolism. A theoretical guideline is given for the use of K(+) -analogues for imaging neuronal activity with general implications for the use of metal ions in neuroimaging. © 2012 The Authors. Journal of Neurochemistry © 2012 International Society for Neurochemistry.

  12. Defects that control the properties of Tl- and Hg-based superconductors

    International Nuclear Information System (INIS)

    Jorgensen, J.D.; Chmaissem, O.; Hinks, D.G.; Mitchell, J.F.; Wagner, J.L.; Univ. of North Dakota, Grand Forks, ND; Jensen, W.R.; Dabrowski, B.; Northern Illinois Univ., DeKalb, IL

    1997-03-01

    Defects that affect T c in Tl 2 Ba 2 CuO 6+δ and HgBa 2 CuO 4+δ and HgBa 2 CuO 4+δ have been characterized by neutron powder diffraction. In Tl 2 Ba 2 CuO 6+δ , the dominant defect is interstitial oxygen between the two Tl-O planes, but Cu substitution on the Tl site also affects properties and there is evidence for a second oxygen defect for compositions in the vicinity of maximum T c . In HgBa 2 CuO 4+δ , there are two competing oxygen defects in the Hg layer. The relative concentrations of these defects switches upon passing from the underdoped region, through the maximum T c , to the overdoped region. This remarkable behavior could result from a change in the topology of the Fermi surface upon passing through the van Hove singularity

  13. Degradation of myocardial perfusion SPECT images caused by contaminants in thallous (201Tl) chloride

    International Nuclear Information System (INIS)

    Staelens, Steven G.; Wit, Tim C. de; Lemahieu, Ignace A.; Beekman, Freek J.

    2008-01-01

    Thallous ( 201 Tl) chloride is a single-photon emission computed tomography (SPECT) tracer mainly used for assessing perfusion and viability of myocardial tissue. 201 Tl emits X-rays around 72 keV and gammas at 167 keV, and has a half-life of 73 h. Regulations allow an intrinsic contamination up to 3-5%, which is mainly caused by 200 Tl (368 keV; 26 h) and by 202 Tl (439 keV; 12.2 days). Contra-intuitive to the low-level percentages in which these contaminants are present, their impact may be significant because of much higher gamma camera sensitivity for these high-energy photon emissions. Therefore, we investigate the effects of the contaminants in terms of detected fractions of photons in projections and contrast degradation in reconstructed images. Acquisitions of a digital thorax phantom filled with thallous ( 201 Tl) chloride were simulated with a validated Monte Carlo tool, thereby, modelling 1% of contamination by 200 Tl and 202 Tl each. In addition, measurements of a thorax phantom on a dual-headed gamma camera were performed. The product used was contaminated by 0.17% of 200 Tl and 0.24% of 202 Tl at activity reference time (ART). This ART is specified by the manufacturer, thereby, accounting for the difference in half-lives of 201 Tl and its contaminants. These measurements were repeated at different dates associated with various contamination levels. Simulations showed that, with 1% of 200 Tl and 202 Tl, the total contamination in the 72 keV window can rise up to one out of three detected photons. For the 167keV window, the contamination is even more pronounced: more than four out of five detections in this photopeak window originate from contaminants. Measurements indicate that cold lesion contrast in myocardial perfusion SPECT imaging is at maximum close to ART. In addition to a higher noise level, relative contrast decreases 15% 2 days early to ART, which is explained by an increase in 200 Tl contamination. After ART, contrast decreased by 16% when

  14. NaI(Tl) electron energy resolution

    CERN Document Server

    Mengesha, W

    2002-01-01

    NaI(Tl) electron energy resolution eta sub e was measured using the Modified Compton Coincidence Technique (MCCT). The MCCT allowed detection of nearly monoenergetic internal electrons resulting from the scattering of incident 662 keV gamma rays within a primary NaI(Tl) detector. Scattered gamma rays were detected using a secondary HPGe detector in a coincidence mode. Measurements were carried out for electron energies ranging from 16 to 438 keV, by varying the scattering angle. Measured HPGe coincidence spectra were deconvolved to determine the scattered energy spectra from the NaI(Tl) detector. Subsequently, the NaI(Tl) electron energy spectra were determined by subtracting the energy of scattered spectra from the incident source energy (662 keV). Using chi-squared minimization, iterative deconvolution of the internal electron energy spectra from the measured NaI(Tl) spectra was then used to determine eta sub e at the electron energy of interest. eta sub e values determined using this technique represent va...

  15. Impact of precursor purity on optical properties and radiation detection of CsI:Tl scintillators

    Energy Technology Data Exchange (ETDEWEB)

    Saengkaew, Phannee; Cheewajaroen, Kulthawat; Yenchai, Chadet; Thong-aram, Decho [Chulalongkorn University, Department of Nuclear Engineering, Faculty of Engineering, Bangkok (Thailand); Sanorpim, Sakuntam [Chulalongkorn University, Department of Physics, Faculty of Science, Bangkok (Thailand); Jitpukdee, Manit [Kasetsart University, Department of Applied Radiation and Isotope, Faculty of Science, Bangkok (Thailand); Yordsri, Visittapong; Thanachayanont, Chanchana [Ministry of Science and Technology, National Metal and Materials Technology Center, National Science and Technology Development Agency, Pathumthani (Thailand); Nuntawong, Noppadon [Ministry of Science and Technology, National Electronic and Computer Technology Center, National Science and Technology Development Agency, Pathumthani (Thailand)

    2016-08-15

    Cesium iodide doped with thallium (CsI:Tl) crystals was grown to develop the gamma-ray detectors by using low-cost raw materials. Effect of impurities on optical properties and radiation detection performance was investigated. By a modified homemade Bridgman-Stockbarger technique, CsI:Tl samples were grown in two levels of CsI and TlI reactant materials, i.e., having as a very high purity of 99.999 % and a high purity of 99.9 %. XRD measurements indicate CsI:Tl crystals having a good quality with a dominant (110) plane. Having a cubic structure, a lattice constant of CsI crystals of 0.4574 nm and a crystallite size of 43.539 nm were obtained. From the lower-purity raw materials, calcite was found in an orange crystal with a lattice constant of 0.4560 nm and a crystallite size of 43.089 nm. By PL measurements, the optical properties of the CsI:Tl crystals were analyzed. ∝540-nm-wavelength PL peak was observed from the colorless high-purity crystal, and ∝600-nm-wavelength PL peak was observed from the orange crystal. The brighter PL emission was obtained from the orange crystals suggesting impurities. CsI:Tl surface morphology by SEM exhibited a smooth surface with some parallel crystal facets. For electrical properties of high-quality CsI:Tl crystals, the electrical resistances were 230 ± 16 MΩ in cross-sectional direction and 714 ± 136 MΩ in vertical direction with respect to more homogeneous crystal quality in cross-sectional direction than that in vertical direction. TEM measurement was applied to evaluate the microstructure of colorless CsI:Tl crystal with different patterns of a cubic structure. Both CsI:Tl crystals show good efficiencies and good resolutions. Maintaining the same electronic conditions and amplifications, the colorless CsI:Tl scintillators represented a higher detection efficiency at 122 keV of Co-57 of 78.4 % and the energy resolution of 23.3 % compared to the detection efficiency of 75.9 % and the energy resolution of 34.6 % of the

  16. Centers responsible for the TL peaks of willemite mineral estimated by EPR analysis

    Energy Technology Data Exchange (ETDEWEB)

    Gundu Rao, T.K. [Instituto de Física, Universidade de São Paulo, Rua do Matão, Travessa R, 187, CEP 05508-090, São Paulo, SP (Brazil); Cano, Nilo F., E-mail: nilo.cano@unifesp.br [Departamento de Ciências do Mar, Universidade Federal de São Paulo, Rua Doutor Carvalho de Mendonça, 144, CEP 11070-102, Santos, SP (Brazil); Silva-Carrera, Betzabel N.; Ferreira, Reinaldo M. [Instituto de Física, Universidade de São Paulo, Rua do Matão, Travessa R, 187, CEP 05508-090, São Paulo, SP (Brazil); Javier-Ccallata, Henry S., E-mail: henrysjc@gmail.com [Escuela Profesional de Física, Facultad de Ciencias Naturales y Formales, Universidad Nacional de San Agustín (UNSA), Av. Independencia S/N, Arequipa (Peru); Watanabe, Shigueo, E-mail: watanabe@if.usp.br [Instituto de Física, Universidade de São Paulo, Rua do Matão, Travessa R, 187, CEP 05508-090, São Paulo, SP (Brazil)

    2016-09-15

    The mineral willemite (Zn{sub 2}SiO{sub 4}) exhibits five thermoluminescence (TL) peaks approximately at 160, 225, 260, 310 and 400 °C. Electron paramagnetic resonance (EPR) studies were carried out to study the defect centers induced in the mineral by gamma irradiation and also to identify the centers responsible for the TL process. Room temperature EPR spectrum of irradiated mineral is a superposition of at least four distinct centers. One of the centers (center I) with an isotropic g factor 2.0114 is attributable to an intrinsic O{sup −} type center and the center correlates with the TL peak at 160 °C. Center II exhibiting hyperfine lines is also tentatively assigned to an O{sup −} ion and is related to the low temperature TL peak at 160 °C. Center III is characterized by an axially symmetric g-tensor with principal values g{sub ||}=2.0451 and g{sub ⊥}=2.011 and is identified as an O{sub 2}{sup −} ion. This center appears to be related to 160, 225 and 260 °C TL peaks. Center IV with principal g-values g{sub ||}=2.0025 and g{sub ⊥}=2.0088 is attributed to an F{sup +}-type center (singly ionized oxygen vacancy) and is the likely recombination center for TL peaks between 160 and 310 °C.

  17. Emission properties of thermoluminescence from natural quartz - blue and red TL response to absorbed dose

    International Nuclear Information System (INIS)

    Hashimoto, T.; Yokosaka, K.; Habuki, H.

    1987-01-01

    The TL spectrometry of natural quartz exposed to a gamma radiation dose of 8.8 kGy proved that the red TL, mainly from volcanically originated quartz, has a broad emission band with a peak around 620 nm, while the blue TL from plutonically originated quartz also has a broad emission band giving a peak around 470 nm. These typical red or blue intrinsic colours were also confirmed on the thermoluminescence colour images (TLCI). Exceptionally, a pegmatite quartz changed its TLCI colour from red to blue when the absorbed dose was increased. By using colour filter assemblies, all these quartz samples were shown to emit mainly blue and red TLs, which have distinctly different TL responses to the absorbed dose; the blue invariably showed a supralinearity relation between 1 and 10 kGy dose. For the purpose of dating, the use of red TL, is preferable. The red TL component is related to the impurity Eu content in quartz minerals. (author)

  18. Computerized study with 201Tl of the gold thyroid node

    International Nuclear Information System (INIS)

    Palermo, F.; Saitta, B.; Coghetto, F.; Tiberio, M.; Caldato, L.

    1982-01-01

    Because of its physical and potassium-metabolic characteristics 201 Tl is more suitable than 131 Cs for radioisotopic studies of the cold thyroid nodule, with the further diagnostic possibility of quantitatively assessing intranodular behaviour for a specific differentiation among different kinds of neoformations. Using a gamma-camera on line with a computer data processing device, sequential scintiscans were recorded for the first 20-30 min after i.v. administration of 15-20 μCi/kg of radiothallium; delayed sequences were taken at 40-60 min if intranodular uptake appeared. A quantitative appraisal was made of the differential 201 Tl uptake-ratio between nodule and healthy thyroid tissue (density-index) and the multiparameter analysis of thyroid time/activity curves generated on the relative regions of interest (ROIs). This computerized study, in 120 out of 293 patients submitted to this radiothallium test, has shown a) diagnostic agreement between clinical-histological and radioisotopic findings in 76 out of 79 colloid-cystic or degenerative neoformations, in all 16 malignant and in 23 out of 25 hyperplastic benign nodules; b) significant statistical difference of the density-index in solid versus cystic but not between benign and malignant nodules; c) different 201 Tl kinetics behaviour in different kinds of solid thyroid lesions with a satisfactory statistical difference of the radiothallium nodular dissappearance-index. (orig.) [de

  19. Event-related potential evidence for the processing efficiency theory.

    Science.gov (United States)

    Murray, N P; Janelle, C M

    2007-01-15

    The purpose of this study was to examine the central tenets of the processing efficiency theory using psychophysiological measures of attention and effort. Twenty-eight participants were divided equally into either a high or low trait anxiety group. They were then required to perform a simulated driving task while responding to one of four target light-emitting diodes. Cortical activity and dual task performance were recorded under two conditions -- baseline and competition -- with cognitive anxiety being elevated in the competitive session by an instructional set. Although driving speed was similar across sessions, a reduction in P3 amplitude to cue onset in the light detection task occurred for both groups during the competitive session, suggesting a reduction in processing efficiency as participants became more state anxious. Our findings provide more comprehensive and mechanistic evidence for processing efficiency theory, and confirm that increases in cognitive anxiety can result in a reduction of processing efficiency with little change in performance effectiveness.

  20. Electrochemically produced alumina as TL detector

    International Nuclear Information System (INIS)

    Osvay, M.

    1996-01-01

    The goal of this work was to compare the TL properties of various electrochemically produced alumina layers (E-AIO) in order to investigate the effect of the electrolyte and the Mg content on the alloys. It has been found that the TL sensitivity of oxidised layers is more influenced by the type of electrolyte, than by the composition of alloy. Hard oxide layer evolved in reduction electrolyte has rather different character compared to other alumina production investigated. The effect of reducing media seems to be very important during preparation of alumina layer. One of the advantages properties of E-AIO is, that it serve a promising method to increase the measuring range of TL method above 10 kGy as well. (author)

  1. Accidental and retrospective dosimetry using TL method

    International Nuclear Information System (INIS)

    Mesterházy, D.; Osvay, M.; Kovács, A.; Kelemen, A.

    2012-01-01

    Retrospective dosimetry is one of the most important tools of accidental dosimetry for dose estimation when dose measurement was not planned. In the affected area many objects can be applied as natural dosimeters. The paper discusses our recent investigations on various electronic components and common salt (NaCl) having useful thermoluminescence (TL) properties. Among materials investigated the electronic components of cell phones seem promising for retrospective dosimetry purposes, having high TL responses, proper glow curve peaks and the intensity of TL peaks vs. gamma dose received provided nearly linear response in the dose range of 10 mGy–1.5 Gy. - Highlights: ► Electronic components and common salt were investigated for accidental and retrospective dosimetry. ► SMD resistors seem promising for retrospective dosimetry purposes. ► Table salt can be used effectively for accidental dosimetry purposes, as well.

  2. Detailed α -decay study of 180Tl

    Science.gov (United States)

    Andel, B.; Andreyev, A. N.; Antalic, S.; Barzakh, A.; Bree, N.; Cocolios, T. E.; Comas, V. F.; Diriken, J.; Elseviers, J.; Fedorov, D. V.; Fedosseev, V. N.; Franchoo, S.; Ghys, L.; Heredia, J. A.; Huyse, M.; Ivanov, O.; Köster, U.; Liberati, V.; Marsh, B. A.; Nishio, K.; Page, R. D.; Patronis, N.; Seliverstov, M. D.; Tsekhanovich, I.; Van den Bergh, P.; Van De Walle, J.; Van Duppen, P.; Venhart, M.; Vermote, S.; Veselský, M.; Wagemans, C.

    2017-11-01

    A detailed α -decay spectroscopy study of 180Tl has been performed at ISOLDE (CERN). Z -selective ionization by the Resonance Ionization Laser Ion Source (RILIS) coupled to mass separation provided a high-purity beam of 180Tl. Fine-structure α decays to excited levels in the daughter 176Au were identified and an α -decay scheme of 180Tl was constructed based on an analysis of α -γ and α -γ -γ coincidences. Multipolarities of several γ -ray transitions deexciting levels in 176Au were determined. Based on the analysis of reduced α -decay widths, it was found that all α decays are hindered, which signifies a change of configuration between the parent and all daughter states.

  3. Binuclear Pt-Tl bonded complex with square pyramidal coordination around Pt: a combined multinuclear NMR, EXAFS, UV-Vis, and DFT/TDDFT study in dimethylsulfoxide solution.

    Science.gov (United States)

    Purgel, Mihály; Maliarik, Mikhail; Glaser, Julius; Platas-Iglesias, Carlos; Persson, Ingmar; Tóth, Imre

    2011-07-04

    the (CN)(4)Pt-Tl(dmso)(5)(+) system by using DFT calculations (B3LYP model) provide bond distances in excellent agreement with the EXAFS data. The four cyanide ligands are located in a square around the Pt atom, while the Tl atom is coordinated in a distorted octahedral fashion with the metal being located 0.40 Å above the equatorial plane described by four oxygen atoms of dmso ligands. The four equatorial Tl-O bonds and the four cyano ligands around the Pt atom are arranged in an alternate geometry. The coordination environment around Pt may be considered as being square pyramidal, where the apical position is occupied by the Tl atom. The optimized geometry of (CN)(4)Pt-Tl(dmso)(5)(+) is asymmetrical (C(1) point group). This low symmetry might be responsible for the unusually large NMR linewidths observed due to intramolecular chemical exchange processes. The nature of the Pt-Tl bond has been studied by MO analysis. The metal-metal bond formation in (CN)(4)Pt-Tl(dmso)(5)(+) can be simply interpreted as the result of a Pt(5d(z(2)))(2) → Tl(6s)(0) donation. This bonding scheme may rationalize the smaller thermodynamic stability of this adduct compared to the related complexes with (CN)(5)Pt-Tl entity, where the linear C-Pt-Tl unit constitutes a very stable bonding system. © 2011 American Chemical Society

  4. Trithallium tetraselenophosphate Tl3PSe4, and trithallium tetrathioarsenate, Tl3AsS4, by neutron time-of-flight diffraction

    International Nuclear Information System (INIS)

    Alkire, R.W.; Vergamini, P.J.; Larson, A.C.; Morosin, B.

    1984-01-01

    Room-temperature (293 K) single-crystal structure determinations of the isostructural materials Tl 3 PSe 4 and Tl 3 AsS 4 were performed at the Los Alamos National Laboratory Pulsed Neutron Facility. For Tl 3 PSe 4 : Msub(r) = 959.92, Pcmn, a = 9.276 (1), b = 11.036 (2), c = 9.058 (1) A, V = 927.27 A 3 , Z = 4, Dsub(m) = 6.87 (2), Dsub(x) = 6.876 Mg m -3 , lambdasub(neutron) = 0.5 → 5.2 A, F(000) = 252.5 fm. For Tl 3 AsS 4 : Msub(r) = 816.29, Pcmn, a = 9.084 (3), b = 10.877 (3), c = 8.877 (3) A, V = 877.11 A 3 , Z = 4, Dsub(m) = 6.18 (2), Dsub(x) = 6.181 Mg m -3 , lambdasub(neutron) = 0.5 → 5.2 A, F(000) = 177.2 fm. For Tl 3 PSe 4 (Tl 3 AsS 4 ), 1929 (1013) reflections were measured with I > 3sigma(I) and refined by full-matrix least squares to R(F) = 0.061 (0.063). Results on atomic refinement from this study represent an order of magnitude increase in precision over previous single-crystal X-ray structural work using Mo Kα radiation. The PSe 4 3- (AsS 4 3- ) groups have essentially tetrahedral configurations and one Tl + ion shows large anisotropic thermal motion which is structure related. (Auth.)

  5. Characterization and analysis of NaI(Tl) and BGO detectors

    International Nuclear Information System (INIS)

    Harrison, J.R.

    1994-01-01

    There have been many studies concerning the performance characteristics of NaI(Tl) and BGO scintillating crystals, most of which generate data by algorithms rather than from experimentation. Those studies which do deal with collected data, however, usually test only a few detecting units. It was, therefore, the purpose of this project to develop a characterization method and to characterize a large number of scintillators of various sizes and histories as well as to create a performance profile based on the data collected. The energy ranges at which the detectors show relatively good resolution % and photo peak efficiency was also desired for future reference. Enough statistical data was collected and analyzed so that a differentiation between those detectors which perform well and those that do not can be made

  6. Development of surgical gamma probes with TlBr semiconductors and CsI(Tl) scintillators crystals

    International Nuclear Information System (INIS)

    Costa, Fabio Eduardo da

    2006-01-01

    Radio guided surgery, using probes with radiation detectors, has been prominence in the medical area in the last decade. This technique consists in injecting a radioactive substance to concentrate in tumour and assist the localization during the surgical procedure. The radio guided surgeries allowing the identification of lymph node has revolutioned the behavior of tumour in initial stadium when are being spread by lymphatic way. The conditions imposed to the surgery due the proximity between some lymph nodes, demands of the probes, a small diameters and capacity of individual identification of these lymph nodes radiolabelled by a specific tracer. The international market supplies these probes with CdTe semiconductors and scintillators, but there is some time lack a promptly technical assistance in the Brazilian market. This work developed probes with national technology, using CsI(Tl) scintillators crystals and, in substitution to CdTe crystals semiconductors, the TlBr crystal, that is a new semiconductor detector in a world-wide development, with advantages in relation to the CdTe. Both crystals have been grown in IPEN. All the necessary electronics, specially, the preamplifier, that was also a restrictive factor for development of these types of probe in the country, have been developed with components found in the national market. Systematic measures of spatial resolution, spatial selectivity, maximum sensitivity and quality of the shielding have been carried the probes development. The results have shown that the probes, one with the CsI(Tl) crystal and another with TlBr semiconductor presented the requested performance in the international literature for radio guided probes. (author)

  7. Isotopic exchange in a neutron-irradiated mixed-valence compound: Tl3(I) Tl(III)Cl6

    International Nuclear Information System (INIS)

    Fernandez Valverde, S.; Duplatre, G.

    1977-01-01

    The initial distribution of Tl(I) and Tl(III) species, and its change on heating, have been investigated in solid thermal neutron-irradiated Th 4 Cl 6 . An initial ratio of 5/1 for 204 Tl(I)/ 204 Tl(III) is found and this remains constant for integral gamma-doses of 3 to 12 MRad. The variation of the 204 Tl(III) fraction with temperature is found identical to that observed in labelled Tl 4 Cl 6 for which a genuine isotopic exchange has previously been described. It is concluded that the recoil species are rapidly converted, after the recoil processes, into stable ions

  8. Relative Efficiency of Split-plot Design (SPD) to Randomized ...

    African Journals Online (AJOL)

    PROF. O. E. OSUAGWU

    2013-06-01

    Jun 1, 2013 ... West African Journal of Industrial and Academic Research Vol.7 No. 1 June .... effects. They concluded that the proposed efficiency measures provide feasible solutions for .... Fm = d.f for the whole-plot treatment; Fb= d.f for the ...

  9. Gender and Relative Economic Efficiency in Sweet Potato Farms of ...

    African Journals Online (AJOL)

    This study employed the stochastic frontier cost function to measure the level of economic efficiency and its determinants in small-scale sweet potato production in Imo State, Nigeria on gender basis. A multi-stage random sampling technique was used to select 120 sweet potato farmers (64 females and 56 males) in the ...

  10. The relative efficiency of three methods of estimating herbage mass ...

    African Journals Online (AJOL)

    The methods involved were randomly placed circular quadrats; randomly placed narrow strips; and disc meter sampling. Disc meter and quadrat sampling appear to be more efficient than strip sampling. In a subsequent small plot grazing trial the estimates of herbage mass, using the disc meter, had a consistent precision ...

  11. Development of NaI(Tl) scintillating films for imaging soft x-rays

    International Nuclear Information System (INIS)

    Shepherd, J.A.

    1993-01-01

    Thin film NaI(Tl) scintillators, of areas of up to 130 cm 2 , have been fabricated and characterized for use on soft x-ray imaging photomultiplier tubes. Relevant parameters of photon-counting imaging detectors are defined and used to predict the performance of several materials, including CsI(Na), CsI(Tl), CaF 2 (Eu), Lu 2 (SiO 4 )O:Ce, and NaI(Tl), as thin film scintillators on fiber optic substrates. Also, x-ray imaging methodologies are compared. The NaI(Tl) films were vapor-deposited onto quartz and fiber optic substrates using a powder flash deposition technique. When compared to single crystal NaI(Tl), the films were found to have equally high light yield but lower energy resolution. Light yield optimization was studied in detail including the effects of substrate temperature, activator concentration in the evaporant, and boat temperature. Spatial resolution as well as parallax errors are discussed and measured for film thicknesses up to 61 μm. A technique is described that can substantially increase the light collection of high index films on fiber optic disks. The light collection was improved by 20% by coating the disk with potassium silicate before the NaI(Tl) deposition. Large area films, up to 130 cm 2 , had a spatial uniformity of response within ±1.5% for count rate and ±3.5% for light yield, and their spatial resolution exceeded 16.6 lp mm -1 when deposited onto fiber optic substrates. The 8-keV x-ray detection efficiency of the microchannel plate imaging photomultiplier tube coupled to a NaI(Tl) film scintillator is predicted to be 88%. Other uses for the films are also described

  12. Brain SPECT with Tl-201 DDC

    International Nuclear Information System (INIS)

    Bruine, J.F. de.

    1988-01-01

    The development, animal and human experiments and the first clinical results of a new blood flow tracer thallium-201 diethyldithiocarbamate (Tl-201 DDC) are discussed for functional brain imaging with single-photon emission computed tomography (SPECT). 325 refs.; 43 figs.; 22 tabs

  13. Study of the functional characteristics of a NaI(Tl) scintillator gamma spectrometer

    International Nuclear Information System (INIS)

    Jesus Barbosa, S. de.

    1983-01-01

    Functional characteristics (resolution, stability, linearity, counting efficiency) of a NaI(Tl) scintillator gamma spectrometer were studied. Diagrams were plotted and several standard sources ( 241 Am, 109 Cd, 57 Co, 137 Cs, 54 Mn, 22 Na) with gamma energies ranging from 60 to 1275 KeV were used. (C.L.B.) [pt

  14. (Tl, Sb) and (Tl, Bi) binary surface reconstructions on Ge(111) substrate

    Science.gov (United States)

    Gruznev, D. V.; Bondarenko, L. V.; Tupchaya, A. Y.; Yakovlev, A. A.; Mihalyuk, A. N.; Zotov, A. V.; Saranin, A. A.

    2018-03-01

    2D compounds made of Group-III and Group-V elements on the surface of silicon and germanium attract considerable attention due to prospects of creating III-V binary monolayers, which are predicted to hold advanced physical properties. In the present work, we have investigated two such systems, (Tl, Sb)/Ge(111) and (Tl, Bi)/Ge(111) using scanning tunneling microscopy, low energy electron diffraction observations and density-functional-theory calculations. In addition to the previously reported surface structures of 2D (Tl, Sb) and (Tl, Bi) compounds on Si(111), we found new ones, namely, √{ 7} × √{ 7} and 3 × 3. Formation processes and plausible models of their atomic arrangements are discussed.

  15. Response function study of a scintillator detector of NaI(Tl); Estudo da funcao resposta de um detector cintilador de NaI(Tl)

    Energy Technology Data Exchange (ETDEWEB)

    Villa, Marcelo Barros; Costa, Alessandro Martins da, E-mail: amcosta@usp.br [Universidade de Sao Paulo (FFCLRP/USP), Ribeirao Preto, SP (Brazil). Faculdade de Filosofia, Ciencias e Letras. Dept. de Fisica

    2014-07-01

    In measurements of gamma rays with Nai (Tl) scintillator, the detectors output data are pulse height spectra, that corresponding to distorted information about the radiation source due to various errors associated with the crystal scintillation process and electronics associated, instead of power spectra photons. Pulse height spectra are related to the real power spectra by means of scintillator detector response function NaI (Tl). In this work, the response function for a cylindrical crystal of Nal (Tl) of 7,62 x 7,62 cm (diameter x length) was studied, by Monte Carlo method, using the EGSnrc tool to model the transport of radiation, combined with experimental measurements. An inverse response matrix, even with the energy of the square root, which transforms the pulse height spectrum of photon energy spectrum was obtained. The results of this transformation of pulse height spectrum for photon energy spectrum is presented, showing that the methodology employed in this study is suitable.

  16. The unfolding of NaI(Tl) γ-ray spectrum based on maximum likelihood method

    International Nuclear Information System (INIS)

    Zhang Qingxian; Ge Liangquan; Gu Yi; Zeng Guoqiang; Lin Yanchang; Wang Guangxi

    2011-01-01

    NaI(Tl) detectors, having a good detection efficiency, are used to detect gamma rays in field surveys. But the poor energy resolution hinders their applications, despite the use of traditional methods to resolve the overlapped gamma-ray peaks. In this paper, the maximum likelihood (ML) solution is used to resolve the spectrum. The ML method,which is capable of decomposing the peaks in energy difference of over 2/3 FWHM, is applied to scale NaI(Tl) the spectrometer. The result shows that the net area is in proportion to the content of isotopes and the precision of scaling is better than the stripping ration method. (authors)

  17. Reverse 201Tl myocardial redistribution induced by coronary artery spasm

    International Nuclear Information System (INIS)

    Xiang Dingcheng; Yin Jilin; Gong Zhihua; Xie Zhenhong; Zhang Jinhe; Wen Yanfei; Yi Shaodong

    2010-01-01

    Objective: To investigate the mechanism of reverse redistribution (RR) on dipyridamole 201 Tl myocardial perfusion studies in the patients with coronary artery spasm. Methods: Twenty-six patients with coronary artery spasm and presented as RR on dipyridamole 201 Tl myocardial perfusion studies were enlisted as RR group, while other 16 patients with no coronary artery stenosis nor RR were enlisted as control group. Dipyridamole test was repeated during coronary angiography. Corrected thrombolysis in myocardial infarction (TIMI) frame count (CTFC) and TIMI myocardial perfusion grade (TMPG) were measured at RR related and non-RR related coronary arteries before and after dipyridamole infusion respectively. All of the data were analyzed by Student's t-test or χ 2 -test and correlation analysis. Results: Coronary artery angiography showed slower blood flow and lower myocardial perfusion in RR related vessels when compared with non-RR related vessels in RR group, but there was no significant difference among the main coronary arteries in control group. The perfusion defects of RR area at rest were positively related to slower blood velocity at corresponding coronary arteries (r = 0.79, t =10.18, P 0.05). Conclusion: RR is related to the decreased blood flow and myocardial perfusion induced by coronary artery spasm at rest, which may be improved by stress test such as intravenous dipyridamole infusion. (authors)

  18. Principles of Good Practice in SoTL

    Science.gov (United States)

    Felten, Peter

    2013-01-01

    For the Scholarship of Teaching and Learning (SoTL) to be understood as significant intellectual work in the academy, SoTL practitioners need to identify shared principles of good practice. While honoring the diversity of SoTL in its many forms across the globe, such principles can serve as a heuristic for assessing work in our field. These…

  19. Efficiency and abatement costs of energy-related CO2 emissions in China: A slacks-based efficiency measure

    International Nuclear Information System (INIS)

    Choi, Yongrok; Zhang, Ning; Zhou, P.

    2012-01-01

    Highlights: ► We employ a slacks-based DEA model to estimate the energy efficiency and shadow prices of CO 2 emissions in China. ► The empirical study shows that China was not performing CO 2 -efficiently. ► The average of estimated shadow prices of CO 2 emissions is about $7.2. -- Abstract: This paper uses nonparametric efficiency analysis technique to estimate the energy efficiency, potential emission reductions and marginal abatement costs of energy-related CO 2 emissions in China. We employ a non-radial slacks-based data envelopment analysis (DEA) model for estimating the potential reductions and efficiency of CO 2 emissions for China. The dual model of the slacks-based DEA model is then used to estimate the marginal abatement costs of CO 2 emissions. An empirical study based on China’s panel data (2001–2010) is carried out and some policy implications are also discussed.

  20. Value of planar 201Tl imaging in risk stratification of patients recovering from acute myocardial infarction

    International Nuclear Information System (INIS)

    Gibson, R.S.; Watson, D.D.

    1991-01-01

    Although exercise ECG testing has been shown to have important prognostic value after acute myocardial infarction, exercise 201Tl scintigraphy offers several potential advantages, including: (1) increased sensitivity for detecting residual myocardial ischemia; (2) the ability to localize ischemia to a specific area or areas subtended by a specific coronary artery; (3) the ability to identify exercise-induced left ventricular dysfunction, which is manifested by increased lung uptake or transient left ventricular dilation; and (4) more reliable risk stratification of individual patients. The more optimal prognostic efficiency of 201Tl scintigraphy partially results from the fact that the error rate in falsely classifying patients as low risk is significantly smaller with 201Tl scintigraphy than with stress ECG. Because of these substantial advantages, there seems to be adequate rationale for recommending exercise perfusion imaging rather than exercise ECG alone as the preferred method for evaluating mortality and morbidity risks after acute myocardial infarction

  1. Study on the effect of deposition rate and concentration of Eu on the fluorescent lifetime of CsI: Tl thin film

    Energy Technology Data Exchange (ETDEWEB)

    Xie, Yijun; Guo, Lina [University of Electronic Science and Technology of China, State Key Laboratory of Electronic Thin Films and Integrated Devices, School of Optoelectronic Information, Chengdu 610054 (China); Liu, Shuang, E-mail: shuangliu@uestc.edu.cn [University of Electronic Science and Technology of China, State Key Laboratory of Electronic Thin Films and Integrated Devices, School of Optoelectronic Information, Chengdu 610054 (China); Wang, Qianfeng; Zhang, Shangjian; Liu, Yong [University of Electronic Science and Technology of China, State Key Laboratory of Electronic Thin Films and Integrated Devices, School of Optoelectronic Information, Chengdu 610054 (China); Zhong, Zhiyong [University of Electronic Science and Technology of China, State Key Laboratory of Electronic Thin Films and Integrated Devices, Chengdu 610054 (China)

    2017-06-21

    Although there are many new scintillators being developed recently, CsI: Tl is still very efficient among them. The fluorescent lifetime is a very important parameter of CsI: Tl thin film and two series of experiments have been conducted to learn about it. Our experiments, however, have demonstrated that the deposition rate and the codoping of Eu{sup 2+} will significantly influence its fluorescent lifetime. In order to increase the efficiency of the imaging system, we intend to obtain a higher fluorescent lifetime for CsI: Tl thin film by controlling these two conditions. - Highlights: • We used vacuum vapor deposition method to grow the high-quality thin films. • The relationship between the deposition rate and the fluorescent lifetime of CsI: Tl thin film was tested. • Concentration of Eu on fluorescent lifetime of the CsI: Tl thin film was studied.

  2. TL and LOE dosimetric evaluation of diamond films exposed to beta and ultraviolet radiation; Evaluacion dosimetrica TL y LOE de peliculas de diamante expuestas a radiacion beta y ultravioleta

    Energy Technology Data Exchange (ETDEWEB)

    Preciado F, S.; Melendrez, R.; Chernov, V.; Barboza F, M. [Universidad de Sonora, A.P. 13 y A.P. 5-088, 83000 Hermosillo, Sonora (Mexico); Schreck, M. [Universitaet Augsburg, Institut fuer Physik D-86135 (Germany); Cruz Z, E. [ICN, UNAM, 04500 Mexico D.F. (Mexico)

    2005-07-01

    The diamond possesses a privileged position regarding other materials of great technological importance. Their applications go from the optics, microelectronics, metals industry, medicine and of course as dosemeter, in the registration and detection of ionizing and non ionizing radiation. In this work the results of TL/LOE obtained in two samples of diamond of 10 {mu}m thickness grown by the chemical vapor deposition method (CVD) assisted by microwave plasma. The films were deposited in a silicon substrate (001) starting from a mixture of gases composed of CH{sub 4}/H{sub 2} and 750 ppm of molecular nitrogen as dopant. The samples were exposed to beta radiation (Sr{sup 90}/ Y{sup 90}) and ultraviolet, being stimulated later on thermal (TL) and optically (LOE) to evaluate their dosimetric properties. The sample without doping presented high response TL/LOE to the ultraviolet and beta radiation. The TL glow curve of the sample without doping showed two TL peaks with second order kinetics in the range of 520 to 550 K, besides a peak with first order kinetics of more intensity around 607 K. The TL efficiency of the non doped sample is bigger than the doped with nitrogen; however the LOE efficiency is similar in both samples. The results indicate that the CVD diamond possesses excellent perspectives for dosimetric applications, with special importance in radiotherapy due to it is biologically compatible with the human tissue. (Author)

  3. Activation analysis of thallium in urine using the 203Tl(n,2n) 202Tl reaction

    International Nuclear Information System (INIS)

    Korob, R.O.; Cohen, I.M.; Lage, M.; Baro, G.B.

    1976-04-01

    The method developed by the authors of thallium determination in human urine, based on the 203 Tl(n,2n) 202 Tl reaction followed by chemical separation and measurement of the produced 202 Tl by gamma spectrometry, is described. Its application in some cases of intoxication by thallium is reported. The advantages and limitations of the described technique are discussed. (author) [es

  4. Greater efficiency in attentional processing related to mindfulness meditation.

    NARCIS (Netherlands)

    Hurk, P.A.M. van den; Giommi, F.; Gielen, S.C.A.M.; Speckens, A.E.M.; Barendregt, H.P.

    2010-01-01

    In this study, attentional processing in relation to mindfulness meditation was investigated. Since recent studies have suggested that mindfulness meditation may induce improvements in attentional processing, we have tested 20 expert mindfulness meditators in the attention network test. Their

  5. Efficient parallel algorithms for string editing and related problems

    Science.gov (United States)

    Apostolico, Alberto; Atallah, Mikhail J.; Larmore, Lawrence; Mcfaddin, H. S.

    1988-01-01

    The string editing problem for input strings x and y consists of transforming x into y by performing a series of weighted edit operations on x of overall minimum cost. An edit operation on x can be the deletion of a symbol from x, the insertion of a symbol in x or the substitution of a symbol x with another symbol. This problem has a well known O((absolute value of x)(absolute value of y)) time sequential solution (25). The efficient Program Requirements Analysis Methods (PRAM) parallel algorithms for the string editing problem are given. If m = ((absolute value of x),(absolute value of y)) and n = max((absolute value of x),(absolute value of y)), then the CREW bound is O (log m log n) time with O (mn/log m) processors. In all algorithms, space is O (mn).

  6. TL and OSL studies of carbon doped magnesium aluminate (MgAl2O4:C)

    Science.gov (United States)

    Raj, Sanu S.; Mishra, D. R.; Soni, Anuj; Grover, V.; Polymeris, G. S.; Muthe, K. P.; Jha, S. K.; Tyagi, A. K.

    2016-10-01

    The MgAl2O4:C has been synthesized by using two different methods by electron gun and vacuum assisted melting of MgAl2O4 in presence of graphite. The MgAl2O4:C phosphor thus developed by these two different methods have similar types of the TL/OSL defects with multiple overlapping TL glow peaks from 100 °C to 400 °C. The Computerized Curve De-convolution Analysis (CCDA) has been used to measure TL parameters such as thermal trap depth, frequency factor and order of kinetic associated with charge transfer process in TL phenomenon. The investigated TL/OSL results show that these two methods of incorporating carbon in MgAl2O4 have generated closely resemble the defects of similar types in MgAl2O4:C lattice. However, the MgAl2O4:C synthesized by electron gun shows relatively larger concentration of the TL/OSL defects as compared to MgAl2O4:C synthesized using vacuum assisted melting method. The photo-ionization cross-section (PIC) associated with fastest OSL component of MgAl2O4: C is found to be ∼ 0.5 times than that of fastest OSL component of commercially available dosimetric grade α-Al2O3:C. The MgAl2O4:C thus developed shows good dynamic OSL dose linearity from few mGy to 1 Gy. This work reveals that MgAl2O4:C could be developed as potential tissue equivalent OSL / TL material.

  7. TL and OSL dosimetric properties of Opal gemstone for gamma radiation dosimetry

    International Nuclear Information System (INIS)

    Antonio, Patrícia L.; Gronchi, Claudia C.; Oliveira, Raquel A.P.; Khoury, Helen J.; Caldas, Linda V.E.

    2016-01-01

    In this work, the response of the natural material Opal was studied in relation to its thermoluminescence (TL) and optically stimulated luminescence (OSL), after exposure to the gamma radiation of a "6"0Co source. The structure of the powdered Opal was verified using the X-ray diffraction, scanning electronic microscopy and energy-dispersive X-ray spectroscopy techniques. The material, in its stone form, was turned into powder and mixed to Teflon (also in powder) in three different concentrations, and then pellets were manufactured. The aim of this work was to evaluate the response of these pellets in high-doses of gamma radiation beams, and to observe their possible application as dosimeters, using the TL and OSL techniques. The dosimetric properties of the samples were analyzed by means of different tests, as: TL emission curves and OSL signal decay curves, reproducibility of TL and OSL response, minimum detectable dose, TL and OSL dose–response curves (5 Gy–10 kGy), and fading. The results obtained in this work, for the TL and OSL phenomena, demonstrated that the pellets of Opal + Teflon present an adequate performance e possibility of use as dosimeters in beams of high-dose gamma radiation. - Highlights: • The XRD, SEM and EDX techniques were used to investigate powdered Opal. • Pellets of three different concentrations of Opal and Teflon were studied. • The dosimetric properties of the Opal + Teflon pellets were verified. • TL and OSL techniques were used to analyze the characteristics of the pellets. • Pellets of concentration of 2:1 (Opal:Teflon) presented the most adequate results.

  8. Effects of ischemic-like insult on myocardial 201Tl accumulation

    International Nuclear Information System (INIS)

    Goldhaber, S.Z.; Newell, J.B.; Alpert, N.M.; Andrews, E.; Pohost, G.M.; Ingwall, J.S.

    1983-01-01

    Despite extensive clinical use of thallium-201 ( 201 Tl) for myocardial imaging, the effect of ischemia on myocardial accumulation and release of 201 Tl independent of flow has not been fully defined. Therefore, myocardial accumulation of 201 Tl in response to ischemic-like myocardial injury was assessed in vitro using the cultured fetal mouse heart preparation. Cultured fetal mouse hearts (n . 311) were subjected to injury simulating ischemia by deprivation of oxygen and oxidizable substrates for periods ranging from 15 minutes to 10 hours. The extent of irreversible injury was determined by the percentage of lactic dehydrogenase (LDH) lost from the hearts to the culture medium during recovery from injury. Injury was essentially reversible at 1 hour of insult. The fraction of 201 Tl content in injured compared with control hearts was not significantly lower after 1 hour of insult. By 3 hours of insult, irreversible injury as assessed by loss of LDH was detectable and the extent of injury increased progressively through 10 hours. During the 3-10-hour period of irreversible injury, 201 Tl accumulation within injured hearts compared with controls was related in a monotonically decreasing fashion to the loss of LDH as described by a mathematical kinetic model that fit the observations closely (R2 greater than 0.99). These results indicate that in this organ culture preparation, in which there is effectively an unlimited reservoir of 201 Tl and no confounding effects of perfusion, the time-dependent 201 Tl accumulation is determined by the extent of irreversible injury

  9. Structure and scintillation properties of CsI(Tl) films on Si single crystal substrates

    Energy Technology Data Exchange (ETDEWEB)

    Guo, Lina [State Key Laboratory of Electronic Thin Films and Integrated Devices, School of Optoelectronic Information, University of Electronic Science and Technology of China, Chengdu 610054 (China); Liu, Shuang, E-mail: shuangliu@uestc.edu.cn [State Key Laboratory of Electronic Thin Films and Integrated Devices, School of Optoelectronic Information, University of Electronic Science and Technology of China, Chengdu 610054 (China); Chen, Dejun; Zhang, Shangjian; Liu, Yong; Zhong, Zhiyong [State Key Laboratory of Electronic Thin Films and Integrated Devices, School of Optoelectronic Information, University of Electronic Science and Technology of China, Chengdu 610054 (China); Falco, Charles M. [University of Arizona, College of Optical Sciences, AZ 85721 (United States)

    2016-10-30

    Highlights: • We obtained the desired micro-columnar structure of CsI(Tl) films on the orienting Si substrates. • We improved the micro-columnar structure of CsI(Tl) films under the relatively large deposition rate through using the substrate with a pre-deposited CsI nanolayer. • We modeled the interface structures between the CsI(Tl) films with (200) and (310) orientation and Si(111) substrates to explain the preferred orientation of film under the influence of the orienting substrate significantly. • We gained a new spectrum of the CsI(Tl) films peaked at 740 nm wavelength. - Abstract: CsI(Tl) scintillation films fabricated on glass substrates are widely applied for X-ray imaging because their ability to grow in micro-columnar structure and proper emission wavelength matching CCD cameras. But the coupling process between the CsI(Tl) films and Si-based photo detector would cause coupling loss. In this work, CsI(Tl) films were deposited on the orienting Si substrates and the Si substrates covered by the pre-deposited CsI nanolayers. Structure and scintillation properties of films were examined by using scanning electron microscopy, X-ray diffraction, photoluminescence and radioluminescent spectrum. The films deposited on the orienting Si substrates show the micro-columnar morphology with perfect single crystalline structure and the photoluminescence spectra with bimodal distribution. The performances of the films prepared on the pre-deposited CsI nanolayer, containing micro-columns structure and the light yield are improved.

  10. Structure and scintillation properties of CsI(Tl) films on Si single crystal substrates

    International Nuclear Information System (INIS)

    Guo, Lina; Liu, Shuang; Chen, Dejun; Zhang, Shangjian; Liu, Yong; Zhong, Zhiyong; Falco, Charles M.

    2016-01-01

    Highlights: • We obtained the desired micro-columnar structure of CsI(Tl) films on the orienting Si substrates. • We improved the micro-columnar structure of CsI(Tl) films under the relatively large deposition rate through using the substrate with a pre-deposited CsI nanolayer. • We modeled the interface structures between the CsI(Tl) films with (200) and (310) orientation and Si(111) substrates to explain the preferred orientation of film under the influence of the orienting substrate significantly. • We gained a new spectrum of the CsI(Tl) films peaked at 740 nm wavelength. - Abstract: CsI(Tl) scintillation films fabricated on glass substrates are widely applied for X-ray imaging because their ability to grow in micro-columnar structure and proper emission wavelength matching CCD cameras. But the coupling process between the CsI(Tl) films and Si-based photo detector would cause coupling loss. In this work, CsI(Tl) films were deposited on the orienting Si substrates and the Si substrates covered by the pre-deposited CsI nanolayers. Structure and scintillation properties of films were examined by using scanning electron microscopy, X-ray diffraction, photoluminescence and radioluminescent spectrum. The films deposited on the orienting Si substrates show the micro-columnar morphology with perfect single crystalline structure and the photoluminescence spectra with bimodal distribution. The performances of the films prepared on the pre-deposited CsI nanolayer, containing micro-columns structure and the light yield are improved.

  11. Bragg peak and relative biological efficiency of different ions

    Czech Academy of Sciences Publication Activity Database

    Lokajíček st., Miloš; Judas, Libor; Kundrát, Pavel

    2002-01-01

    Roč. 64, Suppl. 1 (2002), S309-S309 ISSN 0167-8140 R&D Projects: GA AV ČR(CZ) KSK4055109 Keywords : Bragg peak * relative biological efficisncy * radiological mechanism Subject RIV: CC - Organic Chemistry Impact factor: 2.838, year: 2002

  12. Microorganisms for efficient production of melatonin and related compounds

    DEFF Research Database (Denmark)

    2015-01-01

    Recombinant microbial cells and methods for producing 5HTP, melatonin and related compounds using such cells are described. More specifically, the recombinant microbial cell may comprise exogenous genes encoding one or more of an L-tryptophan hydroxylase, a 5- hydroxy-L-tryptophan decarboxylyase...

  13. Measuring the relative efficiency of Ilam hospitals using data envelopment analysis

    Directory of Open Access Journals (Sweden)

    Ehsan Fazeli

    2012-08-01

    Full Text Available Measuring the relative efficiency is one of the most important issues among hospitals in today's economy. These days, we hear that cost reduction is a necessity for survival of business owners and one primary to reduce the expenditures is to increase relative efficiency. The proposed study of this paper first uses output oriented data envelopment analysis (DEA to measure the relative efficiencies of nine hospitals. The proposed model uses four types of employee namely specialists, physicians, technicians and other staffs as input parameters. The model also uses the number of surgeries, hospitalized and radiography as the outputs of the proposed model. Since the implementation of DEA leads us to have more than one single efficient unit, we implement supper efficiency technique to measure the relative efficiency of efficient units.

  14. Microcomputer control of automated TL reader

    International Nuclear Information System (INIS)

    Bjarland, B.

    1980-01-01

    An automatic TL reader has been developed for use within a TLD based personal monitoring service. A 6800 based microcomputer is used for system control, operator communication, calibration and checking of reader operation, and for output of data. The dosimeter identity code is printed in human readable characters on the dosimeter card, and is read by using an optical character recognition unit. The code may include individual sensitivity correction coefficients for the TL chips on the card. The chips are heated with hot nitrogen gas and the thermoluminescence is recorded by a photomultiplier tube circuit, the gain and offset of which are continuously monitored and, when necessary, adjusted, to maintain calibration. The reader may operate in any of seven modes, i.e. reading modes for three types of dosimeters, semiautomatic modes for production of the three types of dosimeters, and a monitor mode. (Auth.)

  15. An analysis of annual maximum streamflows in Terengganu, Malaysia using TL-moments approach

    Science.gov (United States)

    Ahmad, Ummi Nadiah; Shabri, Ani; Zakaria, Zahrahtul Amani

    2013-02-01

    TL-moments approach has been used in an analysis to determine the best-fitting distributions to represent the annual series of maximum streamflow data over 12 stations in Terengganu, Malaysia. The TL-moments with different trimming values are used to estimate the parameter of the selected distributions namely: generalized pareto (GPA), generalized logistic, and generalized extreme value distribution. The influence of TL-moments on estimated probability distribution functions are examined by evaluating the relative root mean square error and relative bias of quantile estimates through Monte Carlo simulations. The boxplot is used to show the location of the median and the dispersion of the data, which helps in reaching the decisive conclusions. For most of the cases, the results show that TL-moments with one smallest value was trimmed from the conceptual sample (TL-moments (1,0)), of GPA distribution was the most appropriate in majority of the stations for describing the annual maximum streamflow series in Terengganu, Malaysia.

  16. Tl and OSL on diopside crystal

    International Nuclear Information System (INIS)

    Cano, N.F.; Watanabe, S.; Mittani, J.C.R.; Yukihara, E.G.

    2006-01-01

    The diopside with chemical composition CaMgSi 2 O 6 is part of an important solid solution series of the pyroxene group. The mineral is commonly found in meteorites and it is an important rock forming mineral of medium and high grade metamorphic rocks which are rich in calcium. In the bibliography it is possible to found several studies on electron spin resonance (ESR), reflectance, etc. but not on thermoluminescence (TL) or optically stimulated luminescence (OSL). In the present work we studied diopside TL and OSL behaviour on natural and natural irradiated samples. The sample used in our study is a white coloured diopside provided by Mineracao Sao Judas located in Sao Paulo, Brazil. The X-Ray Fluorescence technique has shown high concentrations of SiO 2 (55.81 % mol), CaO (23.47 % mol), MgO (18.03 % mol), Al 2 O 3 (1.56 % mol), Fe 2 O 3 (0.53 % mol), K 2 O (0.44 % mol), TiO 2 (0.065 % mol), P 2 O 5 (0.026 % mol), and MnO (0.013 % mol). TL measurements on natural samples show four TL peaks at 160, 260, 360, and 450 C. After beta-irradiation an increment mainly in the low temperature peaks is observed. As for OSL measurements, low OSL signal was observed on natural samples using blue light stimulation and UV detection. The intensity of the signal was observed to increase with the irradiation dose. (Author)

  17. Measurement of conversion coefficients in 208Tl

    International Nuclear Information System (INIS)

    Wendling, F.

    1976-06-01

    A electron spectrometer composed by a Li drifted Si detector and a uniform magnetic field was constructed. The magnetic field is used to focus the electrons on the detector and to filter the other radiations. After the construction the instrument was calibrated in absolute eficience and was used together with a Ge(Li) spectrometer also calibrated, in the measurement of internal conversion coeficients of the 433 and 453 keV transitions in 208 Tl [pt

  18. The precise measurement of TL isotopic compositions by MC-ICPMS: Application to the analysis of geological materials and meteorites.

    Science.gov (United States)

    Rehkämper, Mark; Halliday, Alex N.

    1999-07-01

    The precision of Tl isotopic measurements by thermal ionization mass spectrometry (TIMS) is severely limited by the fact that Tl possesses only two naturally occurring isotopes, such that there is no invariant isotope ratio that can be used to correct for instrumental mass discrimination. In this paper we describe new chemical and mass spectrometric techniques for the determination of Tl isotopic compositions at a level of precision hitherto unattained. Thallium is first separated from the geological matrix using a two-stage anion-exchange procedure. Thallium isotopic compositions are then determined by multiple-collector inductively coupled plasma-mass spectrometry with correction for mass discrimination using the known isotopic composition of Pb that is admixed to the sample solutions. With these procedures we achieve a precision of 0.01-0.02% for Tl isotope ratio measurements in geological samples and this is a factor of ≥3-4 better than the best published results by TIMS. However, without adequate precautions, experimental artifacts can be generated that result in apparent Tl isotopic fractionations of up to one per mil. Analysis of five terrestrial samples indicate the existence of Tl isotopic variations related to natural fractionation processes on the Earth. Two of the three igneous rocks analyzed in this study display Tl isotopic compositions indistinguishable from our laboratory standard, the reference material NIST-997 Tl. A third sample, however, is characterized by ɛ Tl ≈ 2.5 ± 1.5, where ɛ Tl represents the deviation of the 205Tl/ 203Tl ratio of the sample relative to NIST-997 Tl in parts per 10 4. Even larger deviations were identified for two ferromanganese crusts from the Pacific Ocean, which display ɛ Tl-values of +5.0 ± 1.5 and +11.7 ± 1.3. We suggest that the large variability of Tl isotopic compositions in the latter samples are caused by low-temperature processes related to the formation of the Fe-Mn crusts by precipitation and

  19. Overview and theory relating to the concepts of competitiveness, efficiency and productivity

    OpenAIRE

    Latruffe, Laure

    2017-01-01

    This is a brief overview and theory relating to the concepts of competitiveness, efficiency and productivity: concept of competitiveness, measurement of competitiveness, determinants of competitiveness.

  20. Thallium (Tl) sorption onto illite and smectite: Implications for Tl mobility in the environment

    Science.gov (United States)

    Martin, Loïc A.; Wissocq, Aubéry; Benedetti, M. F.; Latrille, Christelle

    2018-06-01

    Clay minerals play a relevant role in the transport and fate of trace elements in the environment. Though illite has been referred as an important Thallium (Tl) bearing phase in soils, mechanisms and affinity of thallium for clay minerals remain poorly known. This study investigated the sorption behavior of thallium as Tl(I) onto illite and smectite, two clay minerals occurring mainly in soils and sediments. Different sorption experiments were carried out under various pH conditions and Tl concentrations, in competition with sodium and calcium at a constant ionic strength of 0.01 mol L-1. Our results showed that illite displayed more affinity than smectite for thallium. With illite, the distribution coefficients (Kd in L kg-1) varied between 102.75 ± 0.17 and 104.0 ± 0.17 in Na solutions versus between 102.25 ± 0.17 and 103.0 ± 0.17 in Ca solutions, depending on pH. With smectite, Kd (in L kg-1) ranged between 102.50 ± 0.16 and 103.20 ± 0.16 and between 101.25 ± 0.16 and 101.95 ± 0.16 in Na and Ca solutions, respectively. Sorption behavior was described with the Multi-Site Ion Exchanger model and selectivity coefficients with respect to protons were calculated for the first time. In all cases, independently of clay mineral and background electrolyte, low capacity but highly reactive sites were dominant in thallium uptake, highlighting Tl affinity for those sites. Moreover, the exchangeable and reversible interactions between Tl+ and clays reactive sites suggested that in changing conditions, thallium could be released in solution. The role of clay minerals in thallium environmental cycle is evident and confirmed illite to be a dominant Tl bearing phase, in some environment competing with manganese oxides. Compared to others Tl bearing mineral phases, clays are ranked as follows: MnO2 > illite > smectite ∼ ferrihydrite ≥ Al2O3 ∼ goethite > SiO2. Finally, over the three monovalent cations (Tl, Rb, Cs) Tl is the one less sorbed on illite independently of

  1. Light backscattering efficiency and related properties of some phytoplankters

    Science.gov (United States)

    Ahn, Yu-Hwan; Bricaud, Annick; Morel, André

    1992-11-01

    By using a set-up that combines an integrating sphere with a spectroradiometer LI-1800 UW, the backscattering properties of nine different phytoplankters grown in culture have been determined experimentally for the wavelengths domain ν = 400 up to 850 nm. Simultaneously, the absorption and attenuation properties, as well as the size distribution function, have been measured. This set of measurements allowed the spectral values of refractive index, and subsequently the volume scattering functions (VSF) of the cells, to be derived, by operating a scattering model previously developed for spherical and homogeneous cells. The backscattering properties, measured within a restricted angular domain (approximately between 132 and 174°), have been compared to theoretical predictions. Although there appear some discrepancies between experimental and predicted values (probably due to experimental errors as well as deviations of actual cells from computational hypotheses), the overall agreement is good; in particular the observed interspecific variations of backscattering values, as well as the backscattering spectral variation typical of each species, are well accounted for by theory. Using the computed VSF, the measured backscattering properties can be converted (assuming spherical and homogeneous cells) into efficiency factors for backscattering ( overlineQbb) . Thhe spectral behavior of overlineQbb appears to be radically different from that for total scattering overlineQb. For small cells, overlineQ (λ) is practically constant over the spectrum, whereas overlineQb(λ) varies approximately according to a power law (λ -2). As the cell size increases, overlineQbb conversely, becomes increasingly featured, whilst overlineQb becomes spectrally flat. The chlorophyll-specific backscattering coefficients ( b b∗ appear highly variable and span nearly two orders of magnitude. The chlorophyll-specific absorption and scattering coefficients, a ∗ and b ∗, are mainly ruled by

  2. The relative efficiency of bank branches in lending and borrowing: An application of data envelopment analysis

    Directory of Open Access Journals (Sweden)

    G van der Westhuizen

    2014-08-01

    Full Text Available The relative efficiency of fifty-two branches of a small South African bank was estimated using Data Envelopment Analysis (DEA.  A factor responsible for the difference in efficiency between branches might be the difference in managing the asset (loans and the liability (deposit side of the balance sheet.  For this reason, the relative efficiency of the lending and borrowing activities was also estimated and compared to the relative efficiency of the combined (lending and borrowing activities.In the case of the efficiency estimates for loans and deposits, the indications are that the branches were more efficient in managing the liability side (deposits than  in managing the asset side (loans.  This means that purchased funds were not utilised efficiently.

  3. Efficient hemodynamic event detection utilizing relational databases and wavelet analysis

    Science.gov (United States)

    Saeed, M.; Mark, R. G.

    2001-01-01

    Development of a temporal query framework for time-oriented medical databases has hitherto been a challenging problem. We describe a novel method for the detection of hemodynamic events in multiparameter trends utilizing wavelet coefficients in a MySQL relational database. Storage of the wavelet coefficients allowed for a compact representation of the trends, and provided robust descriptors for the dynamics of the parameter time series. A data model was developed to allow for simplified queries along several dimensions and time scales. Of particular importance, the data model and wavelet framework allowed for queries to be processed with minimal table-join operations. A web-based search engine was developed to allow for user-defined queries. Typical queries required between 0.01 and 0.02 seconds, with at least two orders of magnitude improvement in speed over conventional queries. This powerful and innovative structure will facilitate research on large-scale time-oriented medical databases.

  4. Tl and OSL dosimetry of diamond films CVD pure and unpurified with boron-carbon

    International Nuclear Information System (INIS)

    Melendrez, R.; Pedroza M, M.; Chernov, V.; Ochoa N, J.D.; Bernal, R.; Barboza F, M.; Castaneda, B.; Goncalves, J.A.N.; Sandonato, G.M.; Cruz Z, E.; Preciado F, S.; Cruz V, C.; Brown, F.; Schreck, M.

    2004-01-01

    The diamond is a material that possesses extreme physical properties, such as its hardness to the radiation, its low chemical reactivity besides its equivalence to the human tissue, which qualify him as an ideal material for radiation dosimetry. In this work, it was studied the thermal and optically stimulated response (Tl and OSL) of polycrystalline diamond films grown by the technique of CVD pure and contaminated with Boron-carbon (B/C) with the intention of characterizing their efficiency like a dosemeter for radiation in a range of 0 - 3000 Gy. For the case of the films without impurities, the Tl curve presents four main peaks, two of them in an interval of temperatures of 150-200 C and other two additional around of 250-400 C. The dependence of the response of integrated Tl and that of OSL always maintained a lineal relationship with the exhibition dose up to 100 Gy. The behavior of the films contaminated with B/C (2000 - 20000 ppm) was established through experiments that involved the signal of OSL and their relationship with the Tl response. It was found that this processes are correlated, since the electrons caught in the traps of low temperature (50 - 250 C) of the Tl they are the electrons that recombining with more probability to provide the signal of OSL. According to these results it is possible to propose the diamond films as a good candidate for dosimetry to, using the traditional technique of Tl so much as well as the but recent of OSL. (Author)

  5. Magnetic properties of Bi- and Tl- based new high-Tc superconductors

    International Nuclear Information System (INIS)

    Togano, K.; Kumakura, H.; Dietderich, D.H.

    1988-01-01

    Upper critical field H c2 and Magnetization curve were measured for new high-T c oxide superconductors of Bi-Sr-Ca-Cu-O and Tl-Ba-Ca-Cu-O systems. H c2 values at 77K for the high-T phase of Bi-Sr-Ca-Cu-O, low-T c (T c (ρ = 0) = 105K) phase of Tl-Ba-Ca-Cu-O, and high-T c (T c (ρ = 0)=115K) phase of Tl-Ba-Ca-Cu-O are 41T, 50T, and 100T, respectively. The magnetization curve of the Bi-Sr-Ca-Cu-O shows a relatively small hysterisis, suggesting a weak pinning force compared to Tl-Ba-Ca-Cu-O as well as Ba 2 YCU 3 O x . Critical current density J c of 600A/Cm 2 at 77K and zero-magnetiac field was attained for the high-T c sample of Tl-Ba-Ca-Cu-O

  6. Evaluation of coronary hemodynamics and exercise 201Tl-myocardial scintigraphy in patients with vasospastic angina

    International Nuclear Information System (INIS)

    Matsumura, Kentaro; Nakase, Emiko; Haiyama, Tohru; Hasegawa, Akira; Saito, Takayuki

    1992-01-01

    To clarify the coronary hemodynamics and myocardial perfusion in patients with vasospastic angina, we performed exercise 201 Tl-myocardial scintigraphy (planar and SPECT) in 72 patients and left coronary digital subtraction angiography (DSA) in 37 patients without significant organic coronary artery stenosis. Coronary artery spasm was documented by coronary angiography in all patients. Fifty-four patients (75%) developed exercise-induced 201 Tl-myocardial perfusion defect on SPECT. 201 Tl pulmonary uptake (L/H) was significantly increased in patients with vasospastic angina. Especially, L/H was higher in patients with multiple small perfusion defect on 201 Tl-SPECT, so that exercise-induced left ventricular dysfunction existed in patients with vasospastic angina and especially in cases of multiple small perfusion defect on 201 Tl-SPECT. The left coronary circulation time (CCT) was prolonged in patients with vasospastic angina. The mechanism of prolonged CCT is still unknown, but we suspected that prolonged CCT was induced by increased peripheral coronary vascular resistance in patients with vasospastic angina. It was concluded that the peripheral coronary circulation was disturbed in patients with vasospastic angina, but its abnormal coronary circulation had no relation to location of spasm-induced vessels. We concluded that impaired coronary microcirculation was taken a part of pathophysiology in vasospastic angina. (author)

  7. Temperature dependence of positron annihilation parameters in Tl-Ba-Ca-Cu-O superconductors

    International Nuclear Information System (INIS)

    Sundar, C.S.; Bharathi, A.; Ching, W.Y.; Jean, Y.C.; Hor, P.H.; Meng, R.L.; Huang, Z.J.; Chu, C.W.

    1990-01-01

    The results of positron lifetime and Doppler broadened line-shape parameter measurements as a function of temperature, across T c , in the Tl-Ba-Ca-Cu-O superconductors are presented. The bulk lifetime in the normal state is found to decrease with the increase in the number of CuO 2 layers. Different temperature dependencies of the annihilation parameters are observed in the various Tl systems containing different numbers of CuO 2 layers. In the Tl 2 Ba 2 Ca 2 Cu 3 O 10 system, an increase in lifetime is observed below T c , whereas in Tl 2 Ba 2 CaCu 2 O 8 , a decrease in lifetime is seen below T c . In the Tl 2 Ba 2 CuO 6 system, the lifetime is observed to be temperature independent. The different temperature variations of positron annihilation parameters are discussed in the light of the positron density distribution, obtained with use of the results of the self-consistent orthogonalized linear combination of atomic orbitals band-structure calculations. It is argued that the different temperature dependencies of the annihilation parameters is related to the positron density distribution within the unit cell and arise due to local charge transfer in the vicinity of the CuO 2 layer in the superconducting state

  8. Relative efficiency of legumes in utilizing soil and fertilizer phosphorus

    International Nuclear Information System (INIS)

    Joshi, O.P.; Prasad, R.; Subbiah, B.V.

    1977-01-01

    A pot-culture study was made at Indian Agricultural Research Institute, New Delhi to study the native P feeding power of six rainy season legumes (green gram, black gram, cowpea, pigeon pea, soyabean and groundnut). Ordinary superphosphate tagged with 32 P was used in the study. At the first harvest (30 days after seeding) soybean and cowpea and at the second harvest (45 days after sowing) cowpea and groundnut removed more P than the other legumes. Pigeon pea removed the least P due to its slow growth. The tracer studies showed that during the first 30 days, groundnut, pigeon pea and soyabean were relatively better feeders of native soil P than the other legumes. Some varietal differences with respect to their capacity to feed on native soil P were also observed and in groundnut the varieties AK-12-24 and Jyoti removed more soil P than the variety NG-268. Differences between the legumes with respect to feeding on native soil P were much less at the second harvest (45 days after seeding). (author)

  9. Relative efficiency of legumes in utilizing soil and fertilizer phosphorus

    Energy Technology Data Exchange (ETDEWEB)

    Joshi, O P; Prasad, R; Subbiah, B V [Indian Agricultural Research Inst., New Delhi. Nuclear Research Lab.

    1977-09-01

    A pot-culture study was made at Indian Agricultural Research Institute, New Delhi to study the native P feeding power of six rainy season legumes (green gram, black gram, cowpea, pigeon pea, soybean and groundnut). Ordinary superphosphate tagged with /sup 32/P was used in the study. At the first harvest (30 days after seeding) soybean and cowpea and at the second harvest (45 days after sowing) cowpea and groundnut removed more P than the other legumes. Pigeon pea removed the least P due to its slow growth. The tracer studies showed that during the first 30 days, groundnut, pigeon pea and soybean were relatively better feeders of native soil P than the other legumes. Some varietal differences with respect to their capacity to feed on native soil P were also observed and in groundnut the varieties AK-12-24 and Jyoti removed more soil P than the variety NG-268. Differences between the legumes with respect to feeding on native soil P were much less at the second harvest (45 days after seeding).

  10. New colour centres in KCl:(Tl+ + Ca2+) and KCl:(Tl+ + Sr2+) crystals

    International Nuclear Information System (INIS)

    Ioan, A.; Topa, V.; Giurgea, M.

    1978-01-01

    Electrolytic colouring under unusual conditions (low temperature and high voltage) gives rise to the appearance of three new absorption bands peaking at 3.2, 2.5, and 1.7 eV and at 2.8, 2.1, and 1.5 eV in KCl:(Tl + + Ca 2+ ) and in KCl:(Tl + + Sr 2+ ) single crystals, respectively. The modifications of the absorption spectra of the coloured crystals induced by the application of a reversed electric field at the colouring temperature or by heat treatment are investigated. It is likely that the colour centre responsible for the new absorption bands is an aggregate centre which, besides an Tl - -complex, contains also at least an Ca(Sr) ion, a trapped electron, and an anionic vacancy. (author)

  11. Thermodynamic Study of Tl6SBr4 Compound and Some Regularities in Thermodynamic Properties of Thallium Chalcohalides

    Directory of Open Access Journals (Sweden)

    Dunya Mahammad Babanly

    2017-01-01

    Full Text Available The solid-phase diagram of the Tl-TlBr-S system was clarified and the fundamental thermodynamic properties of Tl6SBr4 compound were studied on the basis of electromotive force (EMF measurements of concentration cells relative to a thallium electrode. The EMF results were used to calculate the relative partial thermodynamic functions of thallium in alloys and the standard integral thermodynamic functions (-ΔfG0, -ΔfH0, and S0298 of Tl6SBr4 compound. All data regarding thermodynamic properties of thallium chalcogen-halides are generalized and comparatively analyzed. Consequently, certain regularities between thermodynamic functions of thallium chalcogen-halides and their binary constituents as well as degree of ionization (DI of chemical bonding were revealed.

  12. Insight on a novel layered semiconductors: CuTlS and CuTlSe

    Energy Technology Data Exchange (ETDEWEB)

    Aliev, Ziya S., E-mail: ziyasaliev@gmail.com [Institute of Catalysis and Inorganic Chemistry, ANAS, H.Javid ave. 113, AZ1143 Baku (Azerbaijan); Institute of Physics, ANAS, H.Javid ave. 131, AZ1143 Baku (Azerbaijan); Donostia International Physics Center (DIPC), 20080 San Sebastian (Spain); Zúñiga, Fco. Javier [Departamento de Física de la Materia Condensada, Facultad de Ciencia y Tecnología, Universidad del País Vasco, Apdo. 644, 48080 Bilbao (Spain); Koroteev, Yury M. [Institute of Strength Physics and Materials Science, Russian Academy of Sciences, Siberian Branch, 634055 Tomsk (Russian Federation); Tomsk State University, Tomsk, 634050 (Russian Federation); Breczewski, Tomasz [Departamento de Física de la Materia Condensada, Facultad de Ciencia y Tecnología, Universidad del País Vasco, Apdo. 644, 48080 Bilbao (Spain); Babanly, Nizamaddin B. [Institute of Catalysis and Inorganic Chemistry, ANAS, H.Javid ave. 113, AZ1143 Baku (Azerbaijan); Amiraslanov, Imamaddin R. [Institute of Physics, ANAS, H.Javid ave. 131, AZ1143 Baku (Azerbaijan); Politano, Antonio [Department of Physics, University of Calabria, 87036 Rende (CS) (Italy); Madariaga, Gotzon [Departamento de Física de la Materia Condensada, Facultad de Ciencia y Tecnología, Universidad del País Vasco, Apdo. 644, 48080 Bilbao (Spain); Babanly, Mahammad B. [Institute of Catalysis and Inorganic Chemistry, ANAS, H.Javid ave. 113, AZ1143 Baku (Azerbaijan); and others

    2016-10-15

    Single crystals of the ternary copper compounds CuTlS and CuTlSe have been successfully grown from stoichiometric melt by using vertical Bridgman-Stockbarger method. The crystal structure of the both compounds has been determined by powder and single crystal X-Ray diffraction. They crystallize in the PbFCl structure type with two formula units in the tetragonal system, space group P4/nmm, a=3.922(2); c=8.123(6); Z=2 and a=4.087(6); c=8.195(19) Å; Z=2, respectively. The band structure of the reported compounds has been analyzed by means of full-potential linearized augmented plane-wave (FLAPW) method based on the density functional theory (DFT). Both compounds have similar band structures and are narrow-gap semiconductors with indirect band gap. The resistivity measurements agree with a semiconductor behavior although anomalies are observed at low temperature. - Graphical abstract: The crystal structures of CuTl and CuTlSe are isostructural with the PbFCl-type and the superconductor LiFeAs-type tetragonal structure. The band structure calculations confirmed that they are narrow-gap semiconductors with indirect band gaps of 0.326 and 0.083 eV. The resistivity measurements, although confirming the semiconducting behavior of both compounds exhibit unusual anomalies at low temperatures. - Highlights: • Single crystals of CuTlS and CuTlSe have been successfully grown by Bridgman-Stockbarger method. • The crystal structure of the both compounds has been determined by single crystal XRD. • The band structure of the both compounds has been analyzed based on the density functional theory (DFT). • The resistivity measurements have been carried out from room temperature down to 10 K.

  13. Tl-201 per rectum scintigraphy in chronic liver disease: assessment of Tl-201 uptake indices

    International Nuclear Information System (INIS)

    Moon, Won Jin; Choi, Yun Young; Cho, Suk Shin; Lee, Min Ho

    1999-01-01

    Heart to liver ratio on Tl-201 per rectal scintigraphy (shunt index) is known to be useful in the assessment of portal systemic shunt. We assessed Tl-201 uptake pattern and early liver/heart uptake rate of Tl-201 and correlated with shunt index in patients with chronic active hepatitis (CAH) and liver cirrhosis (LC). Fifty eight patients with biopsy-proven chronic liver disease (35 with CAH, 23 with LC) underwent Tl-201 per rectum scintigraphy after instillation of 18.5 MBq of Tl-201 into the upper rectum. We evaluated hepatic uptake (type 1: homogeneous, 2: inhomogeneous segmental, 3: inhomogeneous nonsegmental) and extrahepatic uptake of spleen, heart and kidney (grade 0: no uptake, 1: less than liver, 2: equal to liver, 3: greater than liver). We measured the early liver/heart uptake rate (the slope of the liver to heart uptake ratio for 10 mim) and shunt index (heart to liver uptake ratio). Tl-201 uptake pattern and early liver/heart uptake rate of Tl-201 was correlated with the pathologic diagnosis and shunt index. Hepatic uptake patterns of type 1 and 2 were dominant in CAH (CAH: 27/35, LC: 8/23), and type 3 in LC (CAH: 8/35, LC: 15/23)(p<0.005). The grades of extrahepatic uptake were higher in LC than in CAH (spleen: p<0.001, other soft tissue: p<0.005). The early liver/heart uptake rate of CAH (0.110±0.111) was significantly higher than that of LC (0.014±0.090)(p<0.001). The sensitivity and specificity of the early liver/heart uptake rate were 77.7% and 67.7% in differentiating LC from CAH. There was negative correlation between early liver/heart uptake rate and shunt index (r=-0.3347, p<0.01). Hepatic and extrahepatic uptake pattern and early liver/heart uptake rate on Tl-201 per rectum scintigraphy are useful in the assessment of portal systemic shunt in patients with chronic liver disease

  14. Correlation between TL and OSL properties of CaF2:N

    International Nuclear Information System (INIS)

    Polymeris, George S.; Kitis, George; Tsirliganis, Nestor C.

    2006-01-01

    Natural CaF 2 is very well known thermoluminescent (TL) material, since it has been extensively used as a dosimeter. Its basic advantage is the exhibited high TL sensitivity. In the present work, the optically stimulated luminescence (OSL) sensitivity of this material was studied by exposing it to environmental radiation for time intervals of few hours up to a few days, and was found to be very high. By analyzing the TL glow curves and the OSL decay curves into their individual glow-peaks and components respectively, a relation between specific glow-peaks and OSL components was established. An intense thermal transfer effect occurring during optical stimulation at high temperature was observed and an explanation is offered according to existing models

  15. First approval procedure of the TL dosimetric service of the NPP in Slovenia

    International Nuclear Information System (INIS)

    Janzekovic, H.; Krizman, M.; Pucelj, B.; Stuhec, M.; Zdesar, U.

    2001-01-01

    The individual dosimetry of exposed workers in a NPP is one of the essential parts which demonstrates the radiation protection standards achieved in a facility. According to the current legislation the Ministry of Health of the Republic of Slovenia has the authority to grant approvals to personal dosimetric services which perform the dosimetric monitoring of workers in Slovenia. Due to the fact that the detailed approval procedure is not given in national regulations, the Ministry of Health in 2000 established a group of experts with the task to prepare technical and organising requirements for such approval. Based on international documents [1,2,3] the Approval procedure for the thermoluminescence dosimetric (TL) services was created. Following this procedure the assessment of the TL dosimetric service in the NPP was performed. The problems related to the technical and organising requirements with the emphasise on the QA/QC criteria of the TL dosimetric service will be discussed.(author)

  16. Response function study of a scintillator detector of NaI(Tl)

    International Nuclear Information System (INIS)

    Villa, Marcelo Barros; Costa, Alessandro Martins da

    2014-01-01

    In measurements of gamma rays with Nai (Tl) scintillator, the detectors output data are pulse height spectra, that corresponding to distorted information about the radiation source due to various errors associated with the crystal scintillation process and electronics associated, instead of power spectra photons. Pulse height spectra are related to the real power spectra by means of scintillator detector response function NaI (Tl). In this work, the response function for a cylindrical crystal of Nal (Tl) of 7,62 x 7,62 cm (diameter x length) was studied, by Monte Carlo method, using the EGSnrc tool to model the transport of radiation, combined with experimental measurements. An inverse response matrix, even with the energy of the square root, which transforms the pulse height spectrum of photon energy spectrum was obtained. The results of this transformation of pulse height spectrum for photon energy spectrum is presented, showing that the methodology employed in this study is suitable

  17. Detection of irradiated foods by the thermoluminescence. Relationships between the temperature ranges of integrating TL glow curves and TL glow ratios

    International Nuclear Information System (INIS)

    Sekiguchi, Masayuki; Yamazaki, Masao; Goto, Michiko; Todoriki, Setsuko; Hagiwara, Shoji

    2007-01-01

    Our study demonstrated that the effects of the several temperature ranges for integrating TL glow intensity on the TL glow ratios by using spice-set purchased at a Turkish air port. The spice set had no labeling of irradiation feeds, but nine of 12 spices were judged as irradiated food in this study. Those temperature ranges were defined by evaluating the glow curves of irradiated TLD-100 chip (167-230degC), TLD-100 disc (177-238degC) and Dolomite element (145-258degC). Those are relatively stable and the difference of typical glow peak temperatures of TLD-100 disc in two institutes was less than 2%. On the other hand, those of TLD-100 tip was shift to higher temperature side at about 4degC because of declining of thermal conductance. The temperature ranges defined by TLD-100 were showed that discriminate more clearly between irradiated and nonirradiated spices compared with the full temperature range of TL measurement (70-400degC). With the exception of low glow intensity, background measurement for estimating net glow intensity was not necessary because TL glow ratio was hardly influenced whether the background measured or not. (author)

  18. Real-time in-situ monitoring of the topotactic transformation of TlCu3Se2 into TlCu2Se2

    International Nuclear Information System (INIS)

    Ångström, J.; Sahlberg, M.; Berger, R.

    2015-01-01

    Highlights: • Topotactic transition from TlCu 3 Se 2 to TlCu 2 Se 2 followed in situ. • Synchrotron radiation X-ray powder diffraction enabled short scans. • Relative abundance of phases refined from powder data. • Opens up for studying similar systems in the same manner. - Abstract: The solid state transformation of monoclinic TlCu 3 Se 2 into tetragonal TlCu 2 Se 2 by oxidative copper leaching in concentrated ammonia solution has been studied in situ by the use of synchrotron radiation. The diffraction patterns of parent and daughter phase are both sharp, indicating a strong topotactic relationship between them that effectuates a rapid change by “chimie douce” performed at +19 °C. The transformation rate is strongly connected to the access of oxygen from the surrounding air. The transformation was followed in a real-time mode, being almost complete after 2.5 h with 1 h incubation due to low oxygen content, as shown from refining the diffraction patterns by Rietveld profile technique

  19. Developing SoTL through Organized Scholarship Institutes

    Directory of Open Access Journals (Sweden)

    Elizabeth Marquis

    2015-12-01

    Full Text Available The need to further integrate SoTL into college and university cultures has been discussed relatively frequently in recent teaching and learning literature. While a number of useful strategies to assist in this task have been advanced, one especially promising suggestion is the development of organized, institutionally-recognized scholarship institutes. Centres or units of this sort have been created at higher education institutions in a number of countries, but little published information currently exists about the design of these institutes or the experiences of individuals affiliated with them. To that end, the present study sought to examine the perceived benefits, challenges and design features of teaching and learning scholarship institutes at research-intensive universities worldwide. A website scan and a survey of individuals affiliated with these units were used to collect qualitative and quantitative data of relevance to the research questions. Based on the findings, and on ideas from the existing research institute and scholarship of teaching and learning literatures, a series of recommendations for individuals and campuses interested in developing effective SoTL institutes are provided.

  20. Evaluation of Tl-201 SPECT imaging findings in prostate cancer

    Directory of Open Access Journals (Sweden)

    Sinem Ozyurt

    2015-07-01

    Full Text Available Objectives: To compare with histopathological findings the findings of prostate cancer imaging by SPECT method using Tl-201 as a tumor seeking agent. Methods: The study comprised 59 patients (age range 51-79 years, mean age 65.3 ± 6.8 years who were planned to have transrectal ultrasonography (TRUS-guided biopsies due to suspicion of prostate cancer between April 2011 and September 2011. Early planar, late planar and SPECT images were obtained for all patients. Scintigraphic evaluation was made in relation to uptake presence and patterns in the visual assessment and to Tumor/Background (T/Bg ratios for both planar and SPECT images in the quantitative assessment. Histopathological findings were compatible with benign etiology in 36 (61% patients and malign etiology in 23 (39% patients. Additionally, comparisons were made to evaluate the relationships between uptake patterns,total PSA values and Gleason scores. Results: A statistically significant difference was found between the benign and malignant groups in terms of uptake in planar and SPECT images and T/Bg ratios and PSA values. No statistically significant difference was found between uptake patterns of planar and SPECT images and Gleason scores in the malignant group. Conclusions: SPECT images were superior to planar images in the comparative assessment. Tl-201 SPECT imaging can provide an additional contribution to clinical practice in the diagnosis of prostate cancer and it can be used in selected patients.

  1. 207Pb and 205Tl NMR on Perovskite Type Crystals APbX3 (A = Cs, Tl, X = Br, I)

    Science.gov (United States)

    Sharma, Surendra; Weiden, Norbert; Weiss, Alarich

    1987-11-01

    By 205Tl and 207Pb NM R the chemical shift in polycrystalline samples of binary halides AX, BX2 and ternary halides ABX3 (A = Cs, Tl; B = Pb; X = Br, I) was studied at room temperature. The chemical shift tensors δ ( 205Tl) and δ (207Pb) were determined in magnitude and orientation on single crystals of the orthorhombic TlPbI3. The components of the δ(205Tl) tensor are δx (205Tl) || a = 611ppm; δy (205Tl) || b = 680 ppm; δZ(205Tl) || c = 1329 ppm; δiso(205Tl) = 873.3 ppm (with respect to 3.4 molar aqueous solution of TlOOCCH3). The chemical shift tensor of 207Pb in TlPbI3 shows two orientations. One of them is: δx (207Pb) = 3760 ppm, inclined 30° from b towards c, δy(207Pb) || a = 3485 ppm, δz(207Pb) = 2639 ppm inclined 120° from b towards c. δiso(207Pb) = 3295 ppm (with respect to saturated aqueous solution of Pb(NO3)2). The results are discussed with respect to the crystal structure and a model to explain orientation and anisotropy of the tensors δ(205Tl) and δ(207Pb) in TlPbI3 is proposed. In the system CsPbBr3-x Ix δ(207Pb) was studied on polycrystalline samples. The chemical shift increases with increasing x and negative excess shift is observed.

  2. Improvements in the Tl dosimetry for Radiotherapy

    International Nuclear Information System (INIS)

    Bustos, S.; Velez, G.; Rubio, M.

    1998-01-01

    The thermoluminescent dosimetry (TLD) in vivo has been demonstrated to be one of the most reliable for the control of radiotherapeutic treatments, but the delay in the response is the main disadvantage in its applicability. In this work are presented important improvements and it is demonstrated that maintaining the accuracy and reliability of the technique, it is possible to accelerate the response times at a few hours. To realize this work is utilized a lecturer Harshaw 4000, dosemeters LiF-TLD-100 chips (3.1 x 3.1 x 0.89 mm 3 ) and rods (1 x 1 x 6 mm 3 ). With the implementation of a glow curve analysis program developed in CIEMAT, its obtained a Tl peaks separation in such manner rapid and accurate, by that the thermal treatment of dosemeters may be reduced at one unique annealing pre-irradiation for 1 hr at 400 Centigrade. It is realized a periodical and individual calibration of the TLD and a study of the factors which influencing the ratio Tl signal-dose as linearity, correction by energy, directional response and pride of Tl signal. the results of this study are introducing in a calculation list specially designed and which allows to obtain absorbed dose by TLD starting of the dates (dosimetric peaks area) which appear of the glow curves analysis. The dose is obtained with an accuracy less than 5 %. The dosemeters already irradiated (in vivo) are analysed and informed in only four hours, allowing a greater control of the treatment and a correction of the possible errors for the next session, still in bi fractional treatments. The method implemented results thus accurate, rapid and reliable. (Author)

  3. Cation composition and oxygen content dependence of crystal structure and T sub c for Tl sub 2 sub - sub x Ba sub 2 Ca sub 2 Cu sub 3 sub + sub z O sub y

    CERN Document Server

    Idemoto, Y; Koura, N; Kamiyama, T; Oikawa, K; Izumi, F

    2003-01-01

    Tl sub 2 sub - sub x Ba sub 2 Ca sub 2 Cu sub 3 sub + sub z O sub y (Tl-2223 system) superconducting oxides with various Tl contents and Cu contents were prepared. We investigated the relation between crystal structure and superconducting property dependence of Tl and Cu content. First, we obtained an almost single-phase material at a Tl content 2-x = 1.7 and the Tl-2223 phase remained the main phase in the region of 2 - x >= 0.631 of Tl sub 2 sub - sub x Ba sub 2 Ca sub 2 Cu sub 3 O sub y. T sub c was about 120 K for the Tl-2223 in a wide range of 0.631 <= 2 - x <= 1.761. Second, we obtained a single-phase at 2 - x = 1.777 and Cu content 3 + z = 3.284 of Tl sub 2 sub - sub x Ba sub 2 Ca sub 2 Cu sub 3 sub + sub z O sub y. The T sub c (zero) dependence of Cu/Tl ratio, showed a maximum value of 122 K at Cu/Tl ratio = 2.026. Based on results of crystal structure refinements by powder neutron diffraction, it was found that the change in bond length and angle dependence of average Cu valence were similar fo...

  4. The TL dating of ancient porcelain

    International Nuclear Information System (INIS)

    Leung, P.L.; Stokes, M.J.; Wang Weida; Xia Junding; Zhou Zhixin

    1997-01-01

    The age determination of ancient porcelain using the pre-dose technique in TL dating was reported. The variation of beta dose with depth below the surface of the porcelain slice, the thermal activation characteristic (TAC) for 110 degree C peak, the measurement of paleodose and the estimation of annual dose were studied. The results show that this technique is suitable for authenticity testing of ancient porcelain, but both accuracy and precision for porcelain dating are worse than those for pottery, because porcelain differs from pottery on composition, structure and firing temperature. Besides, some complicated factors in the pre-dose technique would be the possible cause of the greater errors

  5. Prediction of Phase Separation of Immiscible Ga-Tl Alloys

    Science.gov (United States)

    Kim, Yunkyum; Kim, Han Gyeol; Kang, Youn-Bae; Kaptay, George; Lee, Joonho

    2017-06-01

    Phase separation temperature of Ga-Tl liquid alloys was investigated using the constrained drop method. With this method, density and surface tension were investigated together. Despite strong repulsive interactions, molar volume showed ideal mixing behavior, whereas surface tension of the alloy was close to that of pure Tl due to preferential adsorption of Tl. Phase separation temperatures and surface tension values obtained with this method were close to the theoretically calculated values using three different thermodynamic models.

  6. Characterization of cartilaginous tumors with 201Tl scintigraphy

    International Nuclear Information System (INIS)

    Higuchi, Takahiro; Taki, Junichi; Sumiya, Hisashi; Kinuya, Seigo; Nakajima, Kenichi; Tonami, Norihisa

    2005-01-01

    Histological diagnosis and grading of cartilaginous tumors are closely correlated with patient prognosis; consequently, they are essential elements. We attempted to clarify the characteristics of 201 Tl uptake in various histological types of cartilaginous tumors and to assess its clinical value. Twenty-two cases with histologically proven cartilaginous tumors (3 enchondromas, 15 conventional chondrosarcomas (grade I=9, II=5, III=1), 3 mesenchymal chondrosarcomas, and 1 de-differentiated chondrosarcoma) were examined retrospectively. Planar 201 Tl images were recorded 15 mm following intravenous injection of 201 Tl (111 MBq). 201 Tl uptake in the tumor was evaluated visually employing a five-grade scoring system: 0=no appreciable uptake, 1=faint uptake above the background level, 2=moderate uptake, 3=intense uptake but lower than heart uptake and 4=uptake higher than heart uptake. 201 Tl uptake scores were 0 in 3 of 3 enchondromas, 9 of 9 grade I, and 4 of 5 grade II conventional chondrosarcomas. 201 Tl uptake scores were 1 among 1 of 5 grades II and a grade III conventional chondrosarcoma. Mesenchymal chondrosarcoma and de-differentiated chondrosarcoma displayed 201 Tl uptake scores of 2 or 3. Absence of elevated 201 Tl uptake in cartilaginous tumors was indicative of enchondroma or low-grade conventional chondrosarcoma. However, in instances in which 201 Tl uptake is obvious, high-grade chondrosarcoma or variant types should be considered. (author)

  7. Methods, qualitative and quantitative evaluations of 201Tl myocardial scintiscans

    International Nuclear Information System (INIS)

    Buell, U.; Kleinhans, E.; Klepzig, M.; Seiderer, M.; Strauer, B.E.

    1981-01-01

    Exercise 201 Tl myocardial scintiscanning is a technique used to supplement exercise electrocardiography. The procedure employed should be identical to the standard procedure of electrocardiography. If the coronary disease has already been established by coronary angiography and kineventriculography, 201 Tl examinations should be carried out before surgery in order to determine the ''regional functional reserve''. Visual evaluations of the 201 Tl scintiscans should be supplemented by quantification methods. Quantification is also required between 201 Tl examination and surgery and to assure constant diagnostic accuracy in case of examination by different examiners. (orig./MG) [de

  8. Scintillation detector composed by new type of avalanche photodiode and CsI(Tl) crystal

    International Nuclear Information System (INIS)

    He Jingtang; Chen Duanbao; Li Zuhao; Mao Yufang; Dong Xiaoli

    1996-01-01

    Using S5345 type of avalanche photodiode produced by Hamamatsu for the CsI(Tl) crystal readout, the spectrum of γ ray were measured. Energy resolution of 6.8% for 1.27 MeV γ ray from 22 Na source was obtained. The relation between energy resolution and coupling area, dimension of crystal, shaping time and bias were measured

  9. Impact of intense x-ray pulses on a NaI(Tl)-based gamma camera

    NARCIS (Netherlands)

    Koppert, Wilco J C; van der Velden, Sandra; Steenbergen, J H Leo; de Jong, Hugo W A M

    2018-01-01

    INTRODUCTION: In SPECT/CT systems X-ray and -ray imaging is performed sequentially. Simultaneous acquisition may have advantages, for instance in interventional settings. However, this may expose a gamma camera to relatively high X-ray doses and deteriorate its functioning. We studied the NaI(Tl)

  10. A robust AHP-DEA method for measuring the relative efficiency: An application of airport industry

    Directory of Open Access Journals (Sweden)

    Amin Foroughi

    2012-01-01

    Full Text Available Measuring the relative efficiency of similar units has been an important topic of research among many researchers. Data envelopment analysis has been one of the most important techniques for measuring the efficiency of different units. However, there are some limitations on using such technique and some people prefer to use other methods such as analytical hierarchy process to measure the relative efficiencies. Besides, uncertainty in the input data is another issue, which makes some misleading results. In this paper, we present an integrated robust DEA-AHP to measure the relative efficiency of similar units. The proposed model of this is believed to capable of presenting better results in terms of efficiency compared with exclusive usage of DEA or AHP. The implementation of the proposed model is demonstrated for a real-world case study of Airport industry and the results are analyzed.

  11. Assessment of FIV-C infection of cats as a function of treatment with the protease inhibitor, TL-3

    Directory of Open Access Journals (Sweden)

    de Rozières Sohela

    2004-11-01

    Full Text Available Abstract Background The protease inhibitor, TL-3, demonstrated broad efficacy in vitro against FIV, HIV and SIV (simian immunodeficiency virus, and exhibited very strong protective effects on early neurologic alterations in the CNS of FIV-PPR infected cats. In this study, we analyzed TL-3 efficacy using a highly pathogenic FIV-C isolate, which causes a severe acute phase immunodeficiency syndrome, with high early mortality rates. Results Twenty cats were infected with uncloned FIV-C and half were treated with TL-3 while the other half were left untreated. Two uninfected cats were used as controls. The general health and the immunological and virological status of the animals was monitored for eight weeks following infection. All infected animals became viremic independent of TL-3 treatment and seven of 20 FIV-C infected animals developed severe immunodepletive disease in conjunction with significantly (p ≤ 0.05 higher viral RNA loads as compared to asymptomatic animals. A marked and progressive increase in CD8+ T lymphocytes in animals surviving acute phase infection was noted, which was not evident in symptomatic animals (p ≤ 0.05. Average viral loads were lower in TL-3 treated animals and of the 6 animals requiring euthanasia, four were from the untreated cohort. At eight weeks post infection, half of the TL-3 treated animals and only one of six untreated animals had viral loads below detection limits. Analysis of protease genes in TL-3 treated animals with higher than average viral loads revealed sequence variations relative to wild type protease. In particular, one mutant, D105G, imparted 5-fold resistance against TL-3 relative to wild type protease. Conclusions The findings indicate that the protease inhibitor, TL-3, when administered orally as a monotherapy, did not prevent viremia in cats infected with high dose FIV-C. However, the modest lowering of viral loads with TL-3 treatment, the greater survival rate in symptomatic animals of

  12. 48 CFR 952.223 - Clauses related to environment, energy and water efficiency, renewable energy technologies...

    Science.gov (United States)

    2010-10-01

    ... environment, energy and water efficiency, renewable energy technologies, occupational safety, and drug-free workplace. 952.223 Section 952.223 Federal Acquisition Regulations System DEPARTMENT OF ENERGY CLAUSES AND... related to environment, energy and water efficiency, renewable energy technologies, occupational safety...

  13. [Tl(III)(dota)](-): An Extraordinarily Robust Macrocyclic Complex.

    Science.gov (United States)

    Fodor, Tamás; Bányai, István; Bényei, Attila; Platas-Iglesias, Carlos; Purgel, Mihály; Horváth, Gábor L; Zékány, László; Tircsó, Gyula; Tóth, Imre

    2015-06-01

    The X-ray structure of {C(NH2)3}[Tl(dota)]·H2O shows that the Tl(3+) ion is deeply buried in the macrocyclic cavity of the dota(4-) ligand (1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetate) with average Tl-N and Tl-O distances of 2.464 and 2.365 Å, respectively. The metal ion is directly coordinated to the eight donor atoms of the ligand, which results in a twisted square antiprismatic (TSAP') coordination around Tl(3+). A multinuclear (1)H, (13)C, and (205)Tl NMR study combined with DFT calculations confirmed the TSAP' structure of the complex in aqueous solution, which exists as the Λ(λλλλ)/Δ(δδδδ) enantiomeric pair. (205)Tl NMR spectroscopy allowed the protonation constant associated with the protonation of the complex according to [Tl(dota)](-) + H(+) ⇆ [Tl(Hdota)] to be determined, which turned out to be pK(H)Tl(dota) = 1.4 ± 0.1. [Tl(dota)](-) does not react with Br(-), even when using an excess of the anion, but it forms a weak mixed complex with cyanide, [Tl(dota)](-) + CN(-) ⇆ [Tl(dota)(CN)](2-), with an equilibrium constant of Kmix = 6.0 ± 0.8. The dissociation of the [Tl(dota)](-) complex was determined by UV-vis spectrophotometry under acidic conditions using a large excess of Br(-), and it was found to follow proton-assisted kinetics and to take place very slowly (∼10 days), even in 1 M HClO4, with the estimated half-life of the process being in the 10(9) h range at neutral pH. The solution dynamics of [Tl(dota)](-) were investigated using (13)C NMR spectroscopy and DFT calculations. The (13)C NMR spectra recorded at low temperature (272 K) point to C4 symmetry of the complex in solution, which averages to C4v as the temperature increases. This dynamic behavior was attributed to the Λ(λλλλ) ↔ Δ(δδδδ) enantiomerization process, which involves both the inversion of the macrocyclic unit and the rotation of the pendant arms. According to our calculations, the arm-rotation process limits the Λ(λλλλ) ↔

  14. Study on calibration of neutron efficiency and relative photo-yield of plastic scintillator

    International Nuclear Information System (INIS)

    Peng Taiping; Zhang Chuanfei; Li Rurong; Zhang Jianhua; Luo Xiaobing; Xia Yijun; Yang Zhihua

    2002-01-01

    A method used for the calibration of neutron efficiency and the relative photo yield of plastic scintillator is studied. T(p, n) and D(d, n) reactions are used as neutron resources. The neutron efficiencies and the relative photo yields of plastic scintillators 1421 (40 mm in diameter and 5 mm in thickness) and determined in the neutron energy range of 0.655-5 MeV

  15. Market Efficiency within the German Stock Market: A Comparative Study of the Relative Efficiencies of the DAX, MDAX, SDAX and ASE Indices

    OpenAIRE

    Starcevic, Admin; Rodgers, Timothy

    2011-01-01

    It can be implied from the efficient market hypothesis that the more transparent a market is, then the more likely that the market will be efficient. This paper is a study of whether the different transparency standards applied to the different indices quoted on the German stock market have any impact on their relative efficiencies. It is found that the differences in transparency standards do have an impact on market efficiency. The case for a higher level of market efficiency in res...

  16. A theoretical study of CsI:Tl columnar scintillator image quality parameters by analytical modeling

    Energy Technology Data Exchange (ETDEWEB)

    Kalyvas, N., E-mail: nkalyvas@teiath.gr; Valais, I.; Michail, C.; Fountos, G.; Kandarakis, I.; Cavouras, D.

    2015-04-11

    Medical X-ray digital imaging systems such as mammography, radiography and computed tomography (CT), are composed from efficient radiation detectors, which can transform the X-rays to electron signal. Scintillators are materials that emit light when excited by X-rays and incorporated in X-ray medical imaging detectors. Columnar scintillator, like CsI:T1 is very often used for X-ray detection due to its higher performance. The columnar form limits the lateral spread of the optical photons to the scintillator output, thus it demonstrates superior spatial resolution compared to granular scintillators. The aim of this work is to provide an analytical model for calculating the MTF, the DQE and the emission efficiency of a columnar scintillator. The model parameters were validated against published Monte Carlo data. The model was able to predict the overall performance of CsI:Tl scintillators and suggested an optimum thickness of 300 μm for radiography applications. - Highlights: • An analytical model for calculating MTF, DQE and Detector Optical Gain (DOG) of columnar phosphors was developed. • The model was fitted to published efficiency and MTF Monte Carlo data. • A good fit was observed for 300 µm columnar CsI:Tl thickness. • The performance of the 300 µm column thickness CsI:Tl was better in terms of MTF and DOG for radiographic applications.

  17. Non-radiation induced signals in TL dosimetry

    International Nuclear Information System (INIS)

    German, U.; Weinstein, M.

    2002-01-01

    One source of background signals, which are non-radiation related, is the reader system and it includes dark current, external contaminants and electronic spikes. These factors can induce signals equivalent to several hundredths of mSv. Mostly, the effects are minimised by proper design of the TLD reader, but some effects are dependent on proper operation of the system. The other main group of background signals originate in the TL crystal and is due to tribothermoluminescence, dirt, chemical reactions and stimulation by visible or UV light. These factors can have a significant contribution, equivalent to over several mSv, depending on whether the crystal is bare or protected by PTFE. Working in clean environments, monitoring continuously the glow curve and performing glow curve deconvolution are suggested to minimise non-radiation induced spurious signals. (author)

  18. The TL and OSL study of hydroxyapatites for dosimetric applications

    International Nuclear Information System (INIS)

    Alencar, Marcus A. Vallim de

    2009-01-01

    The hydroxyapatite, the principal mineral component of the bone and tooth enamel, is one of the dosimetric materials that has distinguished itself in the high dose and accidents dosimetry, as well as in the dating, for the Electron Paramagnetic Resonance (EPR) technique. For this reason, the hydroxyapatite could also be used as Thermoluminescence (TL) and Optically Stimulated Luminescence (OSL) dosimeter in the dosimetry of high doses and accidents, and also in the archaeological and geological dating. This work presents a brief study of the TL and OSL behaviour of the B type synthetic carbonated hydroxyapatite, observing the possibility to use this material in TL and OSL dosimetry. The samples were irradiated to a dose of 100 Gy and 1000 Gy, and the TL and OSL measurements were obtained by the RISOE TL/OSL reader, model TL/OSL-DA-15B. The first results demonstrate the presence of three peaks in the TL glow curve in the temperatures of 100 deg C, 150 deg C and 280 deg C. The synthetic carbonated hydroxyapatite also presents an OSL signal when the sample is stimulated with blue light and a small OSL signal for stimulation with infrared light (IR). These results indicate the possibility of this synthetic carbonated hydroxyapatite to be used as dose indicator material using the TL and OSL techniques. (author)

  19. Leading the Charge for SoTL--Embracing Collaboration

    Science.gov (United States)

    Cassard, Anita; Sloboda, Brian

    2014-01-01

    The scholarship of teaching and learning (SoTL) enables colleges and universities to assess student learning and measure the outcomes by engaging in meaningful research, and to disseminate this research. The objective of this paper is to give a snapshot of and assess the current thinking behind this scholarship by presenting examples of SoTL, and…

  20. Abnormal 201Tl limb scan due to unilateral tremor

    International Nuclear Information System (INIS)

    Simons, M.; Schelstraete, K.; Bratzlavsky, M.

    1982-01-01

    A abnormal intra- and interextremity distribution pattern on 201 Tl was observed on the limb scan of a patient with a unilateral tremor. This is ascribed to the increased blood flow in the muscles responsible for the tremor. The suggestion is made that the existence of tremor should be considered as a possible explanation for unexpected abnormalities on 201 Tl limb scintigrams

  1. ESR and TL age determination of caliche nodules

    Energy Technology Data Exchange (ETDEWEB)

    Oezer, A.M. (Middle East Technical Univ., Ankara (Turkey)); Wieser, A.; Goeksu, H.Y.; Mueller, P.; Regulla, D.F. (Gesellschaft fuer Strahlen- und Umweltforschung mbH Muenchen, Neuherberg (Germany, F.R.). Inst. fuer Strahlenschutz); Erol, O. (Istanbul Univ. (Turkey). School of Geography and Marine Sciences)

    1989-01-01

    Feasibility of dating caliche nodules by ESR and TL is investigated. For both methods the properties of the dating signal are described. Chemical composition as well as TL glow curves of caliches originating from different localities exhibit some differences. Due to the complexity of the TL glow curves, some samples required a special post-annealing procedure in order to resolve the main TL peak for age determination. Typical ESR calcite signals do not exist in caliche, therefore usefulness of the g=2.0040 ESR signal is studied. The results of TL and ESR ages are found to be compatible except for two samples. Possible causes of the discrepancy in these samples are discussed. It is shown that, with proper treatment of the radiation-induced signals, it was possible to date caliche formations older than 350 ka, which is not achievable with other methods like uranium series disequilibrium and/or radiocarbon dating. (author).

  2. ESR and TL age determination of caliche nodules

    International Nuclear Information System (INIS)

    Oezer, A.M.; Wieser, A.; Goeksu, H.Y.; Mueller, P.; Regulla, D.F.; Erol, O.

    1989-01-01

    Feasibility of dating caliche nodules by ESR and TL is investigated. For both methods the properties of the dating signal are described. Chemical composition as well as TL glow curves of caliches originating from different localities exhibit some differences. Due to the complexity of the TL glow curves, some samples required a special post-annealing procedure in order to resolve the main TL peak for age determination. Typical ESR calcite signals do not exist in caliche, therefore usefulness of the g=2.0040 ESR signal is studied. The results of TL and ESR ages are found to be compatible except for two samples. Possible causes of the discrepancy in these samples are discussed. It is shown that, with proper treatment of the radiation-induced signals, it was possible to date caliche formations older than 350 ka, which is not achievable with other methods like uranium series disequilibrium and/or radiocarbon dating. (author)

  3. The automated Risoe TL dating reader system

    International Nuclear Information System (INIS)

    Boetter-Jensen, L.

    1988-01-01

    The features of the new modified Riso TL dating reader system are described. A vacuum chamber that accommodates the entire 24-position sample changer unit has been designed. The vacuum and N 2 -gas functions are software-controlled. A newly designed heater system is capable of repeated heating cycles to 700 0 C. The sample changer system accommodates fine-grain discs as well as planchettes for coarse grains. Two software-controlled beta irradiators can be attached to the reader, e.g. for predose measurement. The software allows a user without programming expertise to create any desired measuring sequence, and to store and recall data and glow curves for making analyses. (author)

  4. Evaluasi Pengendalian Sistem Informasi Pengiriman pada TL

    Directory of Open Access Journals (Sweden)

    Nelly Nelly

    2011-06-01

    Full Text Available The purpose of this study is to evaluate the control systems on the TL shipping information, in order to discern weaknesses or problems in delivery of enterprise information systems control using CobIT approach. The research method used is the data collecting by observation, checklists, interviews, and literature study. The results achieved are findings and issue recommendations that provide an illustration about a control of the running information delivery systems. From the illustration it is known that on the company’s control of information delivery system, there are still many things that have not been up to standard. The conclusion obtained is that the control of information delivery systems that have been implemented meets only partially the standards set small, so it still needs much improvement. 

  5. Quality control 201TlCl solution obtained at IPEN-CNEN/SP through the direct method of 201Tl preparation

    International Nuclear Information System (INIS)

    Fernandes, L.; Silva, C.P.G. da.

    1991-09-01

    The radiopharmaceutical 201 TlCl is used in Nuclear medicine for myocardial visualization. The solution of 201 TlCl was prepared using 201 Tl obtained by irradiating a natural mercury target with protons. This radionuclide was subjected to different quality control processes to verify the purity required for its use in Medicine. Some of these controls concerned the determination of 200 Tl, 201 Tl and 202 Tl; the chemical identification of 201 Tl +1 ; the hydrazine concentration, mercury contamination and the presence of phosphate. Furthermore, the biologic distribution in Wistar rats and tests for sterility, pyrogens and for toxicity were carried out. It was verified that the solution obtained was in the form of thallous chloride. This radiopharmaceutical can give a good heart image in animals but due to the contamination of 201 Tl with 200 Tl and 202 Tl its use in human beings is not possible unless enriched 202 Hg is used as target of irradiation. (author)

  6. Photoluminescence and absorption spectra of various common TL phosphors - interpretation of TL mechanisms

    International Nuclear Information System (INIS)

    Nagpal, J.S.

    1980-01-01

    Photoluminescence and absorption spectra of TL phosphors TLD-100, CaF 2 :Dy, CaSO 4 :Dy(0.05%wt), CaSO 4 :Tm(0.05%wt) and Mg 2 SiO 4 :Tb have been measured. The absorption spectra are typical of RE 2+ in rare earth doped irradiated phosphors. On heating RE 2+ yields RE 3+ and emission from the excited states of RE 3+ is observed. (author)

  7. Pulse shaper for scintillation detectors with NaI(Tl) or CsI(Tl) crystals

    International Nuclear Information System (INIS)

    Novisov, B.S.; Maksimenko, A.S.; Baryshev, A.V.; Zhukov, A.V.

    1978-01-01

    The basic circuit of a signal shaper for scintillation detectors with NaI(Tl) and CsI(Tl) crystals is described. To increase amplitude resolution, it is suggested to integrate not the whole charge at the photomultiplier output, but a part of the charge during the initial 100 ns of the current pulse; the remaining part of the current signal is compensated directly at the photomultiplier anode by means of an electric circuit. The principal elements of the spectrometric signal shaper include an input transistor amplifier, a compensation circuit, a key element, a shaper amplifier of time pulses, a shaper of signal duration for controlling the key element, and an output spectrometric amplifier. This device, being used, one can shape pulses at durations of 100 ns and more. The shaper restoration time does not exceed 50 ns. When the shaper operates with NaI(Tl) crystals and at counting rate of 10 6 pulse/s, the amplitude resolution with and without the compensation circuit is 17% and 21% respectively

  8. Results from an investigation of the physical origins of nonproportionality in CsI(Tl)

    Science.gov (United States)

    Asztalos, S.; Hennig, W.; Warburton, W. K.

    2011-10-01

    The relative scintillation response per energy deposited by Compton electrons, or nonproportionality, has traditionally been considered an intrinsic scintillator property. However, such an interpretation is inconsistent with recent results that show nonproportionality to depend on external factors such as shaping time, temperature and supplier. Apparently, at least some of the overall nonproportionality has an extrinsic origin. In this work we describe the results from a suite of measurements designed to test the hypothesis that nonproportionality in CsI(Tl) material has an extrinsic component that correlates with impurity levels. Our choice of material was motivated by the excellent energy resolution observed in one bulk crystal (6.4%)—a marked departure from that measured with conventional CsI(Tl) stock (8-8.5%). Six bulk CsI(Tl) crystals were procured and diced into 44 wafers. Using X-ray fluorescence techniques no conclusive evidence for impurities was found in any of the wafers at the 1-50 ppm level. One crystal exhibited a distinct correlation among energy resolution, decay lifetimes, nonproportionality and a very low level of Tl doping.

  9. Results from an investigation of the physical origins of nonproportionality in CsI(Tl)

    International Nuclear Information System (INIS)

    Asztalos, S.; Hennig, W.; Warburton, W.K.

    2011-01-01

    The relative scintillation response per energy deposited by Compton electrons, or nonproportionality, has traditionally been considered an intrinsic scintillator property. However, such an interpretation is inconsistent with recent results that show nonproportionality to depend on external factors such as shaping time, temperature and supplier. Apparently, at least some of the overall nonproportionality has an extrinsic origin. In this work we describe the results from a suite of measurements designed to test the hypothesis that nonproportionality in CsI(Tl) material has an extrinsic component that correlates with impurity levels. Our choice of material was motivated by the excellent energy resolution observed in one bulk crystal (6.4%)-a marked departure from that measured with conventional CsI(Tl) stock (8-8.5%). Six bulk CsI(Tl) crystals were procured and diced into 44 wafers. Using X-ray fluorescence techniques no conclusive evidence for impurities was found in any of the wafers at the 1-50 ppm level. One crystal exhibited a distinct correlation among energy resolution, decay lifetimes, nonproportionality and a very low level of Tl doping.

  10. Emergence of topological and topological crystalline phases in TlBiS2 and TlSbS2

    KAUST Repository

    Zhang, Qingyun; Cheng, Yingchun; Schwingenschlö gl, Udo

    2015-01-01

    Using first-principles calculations, we investigate the band structure evolution and topological phase transitions in TlBiS2 and TlSbS2 under hydrostatic pressure as well as uniaxial and biaxial strain. The phase transitions are identified by parity analysis and by calculating the surface states. Zero, one, and four Dirac cones are found for the (111) surfaces of both TlBiS2 and TlSbS2 when the pressure grows, which confirms trivial-nontrivial-trivial phase transitions. The Dirac cones at the (M) over bar points are anisotropic with large out-of-plane component. TlBiS2 shows normal, topological, and topological crystalline insulator phases under hydrostatic pressure, thus being the first compound to exhibit a phase transition from a topological to a topological crystalline insulator.

  11. Emergence of topological and topological crystalline phases in TlBiS2 and TlSbS2

    KAUST Repository

    Zhang, Qingyun

    2015-02-11

    Using first-principles calculations, we investigate the band structure evolution and topological phase transitions in TlBiS2 and TlSbS2 under hydrostatic pressure as well as uniaxial and biaxial strain. The phase transitions are identified by parity analysis and by calculating the surface states. Zero, one, and four Dirac cones are found for the (111) surfaces of both TlBiS2 and TlSbS2 when the pressure grows, which confirms trivial-nontrivial-trivial phase transitions. The Dirac cones at the (M) over bar points are anisotropic with large out-of-plane component. TlBiS2 shows normal, topological, and topological crystalline insulator phases under hydrostatic pressure, thus being the first compound to exhibit a phase transition from a topological to a topological crystalline insulator.

  12. Development of low background CsI(Tl) and NaI(Tl) crystals for WIMP search

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Hyun Su [Department of Physics, Ewha Womans University, Seoul 120-750 (Korea, Republic of)

    2015-08-17

    We have developed low background CsI(Tl) and NaI(Tl) crystals to search for weakly interacting massive particles as well as to verify the origin of the annual modulation signal observed by the DAMA/LIBRA experiment. Extensive studies about the contamination mechanisim of {sup 137}Cs in CsI powder lead to the growth of ultra-low-background CsI(Tl) crystals. Similar approaches for NaI(Tl) crystals have been applied to reduce internal backgrounds to less than 0.5 counts/kg/day/keV. Status and understanding of backgrounds and background reduction in NaI(Tl) crystals will be discussed.

  13. Clinical use of /sup 201/Tl myocardial scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Senda, K; Imaeda, T; Kato, T; Asada, S; Doi, H

    1977-04-01

    Myocardial imaging with /sup 201/Tl and scinticamera was studied experimentally using specially designed phantoms and clinically in 23 patients with myocardial infarction or other heart disease. In the phantom experiment, quality of image, accumulative count rate, and detectability of the defect were compared to obtain the best technique for their detection, using four different collimators, i.e., converging, pin-hole, 4000-hole, and 140 keV high-resolution, at two photopeak levels of /sup 201/Tl of 75 and 167 keV, and combining a radiation absorber. In patient examination, myocardial images taken at different periods after injection, different detecting conditions of the scinticamera, and various detecting projections were compared. Images of the converging collimator at the 75 keV photopeak revealed considerably higher accumulative counts and relatively higher quality than those of other detecting conditions. It was necessary to take as many images as possible in various projections, in order to detect the location and size of the myocardial ischemic lesion because the lesion was demonstrated as a clear defect only in profile. It became evident that images taken between about 25 and 90 min delineated the myocardium more clearly than those taken in other periods. Normal images taken in 8 patients without ischemic heart disease appeared in the shape of a doughnut of horseshoe, demonstrating mainly the left venticular myocardium. The image was faint in the region of the aortic or mitral valve and thin in the region of the apical wall. A faint image of the right ventricular myocardium was sometimes seen. In 3 patients with valvular heart disease, findings suggested changes in the thickness of myocardium and the distribution of coronary blood flow. In 11 of 12 patients with old myocardial infarction, the location and size of the lesion was detected.

  14. Right ventricular visualization by Tl-201 myocardial scintigraphy in chronic obstructive pulmonary disease

    Energy Technology Data Exchange (ETDEWEB)

    Fujii, Tadashige; Tanaka, Masao; Takeda, Masashi; Matsuzawa, Yukinori; Handa, Kenjiro; Yoshimura, Kazuhiko [Shinshu Univ., Matsumoto, Nagano (Japan). Faculty of Medicine

    1993-04-01

    Tl-201 myocardial scintigraphy was performed in 130 patients with chronic obstructive pulmonary disease (COPD) to evaluate right ventricular hypertrophy, and the clinical significance of this method was studied. Tl-201 uptake ratios of the right ventricle, which represents the ratio of total counts of the right ventricle to counts of the administered dose of Tl-201, was higher in COPD, especially in pulmonary emphysema and B type COPD by Burrows classification than in controls. The grade of visualization of the right ventricle by visual assessment (RVV) was marked (+++) in only a few cases and moderate (++) in many cases (more than 80%) in all diseases except bronchial asthma. The incidence of right ventricular hypertrophy by electrocardiogram, right-sided heart failure and marked dyspnea (Hugh-Jones 4[center dot]5) were very low in cases with RVV grade ++ and very high in cases with +++. The grade of RVV was related to the severity of pulmonary perfusion impairment, although in diffuse panbronchiolitis the RVV was relatively slight compared with the impairment of perfusion. May parameters of pulmonary function such as %VC, FEV1.0%, RV/TLC, V25, %DLCO, Raw, [Delta]N[sub 2] and PaO[sub 2] showed abnormal values in patients with RVV grade of (++) or (+++) in all diseases except bronchial asthma. In COPD, Tl-201 myocardial scintigraphy seems to be useful for assessment of right ventricular overloading, and for follow-up observation and differentiation between cor pulmonale and right ventricular hypertrophy secondary to cardiac diseases by observing Tl-201 uptake of the lung and left ventricle. (author).

  15. Right ventricular visualization by Tl-201 myocardial scintigraphy in chronic obstructive pulmonary disease

    International Nuclear Information System (INIS)

    Fujii, Tadashige; Tanaka, Masao; Takeda, Masashi; Matsuzawa, Yukinori; Handa, Kenjiro; Yoshimura, Kazuhiko

    1993-01-01

    Tl-201 myocardial scintigraphy was performed in 130 patients with chronic obstructive pulmonary disease (COPD) to evaluate right ventricular hypertrophy, and the clinical significance of this method was studied. Tl-201 uptake ratios of the right ventricle, which represents the ratio of total counts of the right ventricle to counts of the administered dose of Tl-201, was higher in COPD, especially in pulmonary emphysema and B type COPD by Burrows classification than in controls. The grade of visualization of the right ventricle by visual assessment (RVV) was marked (+++) in only a few cases and moderate (++) in many cases (more than 80%) in all diseases except bronchial asthma. The incidence of right ventricular hypertrophy by electrocardiogram, right-sided heart failure and marked dyspnea (Hugh-Jones 4·5) were very low in cases with RVV grade ++ and very high in cases with +++. The grade of RVV was related to the severity of pulmonary perfusion impairment, although in diffuse panbronchiolitis the RVV was relatively slight compared with the impairment of perfusion. May parameters of pulmonary function such as %VC, FEV1.0%, RV/TLC, V25, %DLCO, Raw, ΔN 2 and PaO 2 showed abnormal values in patients with RVV grade of (++) or (+++) in all diseases except bronchial asthma. In COPD, Tl-201 myocardial scintigraphy seems to be useful for assessment of right ventricular overloading, and for follow-up observation and differentiation between cor pulmonale and right ventricular hypertrophy secondary to cardiac diseases by observing Tl-201 uptake of the lung and left ventricle. (author)

  16. An application of data envelopment analysis for measuring the relative efficiency in banking industry

    Directory of Open Access Journals (Sweden)

    Mehdi Soltanifar

    2014-05-01

    Full Text Available Measuring the relative efficiency of banking industry has been a popular subject among both practitioners and academicians. Data envelopment analysis (DEA has been widely applied for different purposes. This paper presents an empirical investigation to measure the relative efficiency of various banks located in province of Semnan, Iran. The proposed study uses DEA method to rank all units and using Anderson and Peterson method (1993 [Andersen, P., & Petersen, N. C. (1993. A procedure for ranking efficient units in data envelopment analysis. Management Science, 39, 1261-1264], we provide some super efficiency for inefficient units. The study also provides reference numbers for inefficient units and gives some target values for all inefficient units.

  17. Relative efficiency and sample size for cluster randomized trials with variable cluster sizes.

    Science.gov (United States)

    You, Zhiying; Williams, O Dale; Aban, Inmaculada; Kabagambe, Edmond Kato; Tiwari, Hemant K; Cutter, Gary

    2011-02-01

    The statistical power of cluster randomized trials depends on two sample size components, the number of clusters per group and the numbers of individuals within clusters (cluster size). Variable cluster sizes are common and this variation alone may have significant impact on study power. Previous approaches have taken this into account by either adjusting total sample size using a designated design effect or adjusting the number of clusters according to an assessment of the relative efficiency of unequal versus equal cluster sizes. This article defines a relative efficiency of unequal versus equal cluster sizes using noncentrality parameters, investigates properties of this measure, and proposes an approach for adjusting the required sample size accordingly. We focus on comparing two groups with normally distributed outcomes using t-test, and use the noncentrality parameter to define the relative efficiency of unequal versus equal cluster sizes and show that statistical power depends only on this parameter for a given number of clusters. We calculate the sample size required for an unequal cluster sizes trial to have the same power as one with equal cluster sizes. Relative efficiency based on the noncentrality parameter is straightforward to calculate and easy to interpret. It connects the required mean cluster size directly to the required sample size with equal cluster sizes. Consequently, our approach first determines the sample size requirements with equal cluster sizes for a pre-specified study power and then calculates the required mean cluster size while keeping the number of clusters unchanged. Our approach allows adjustment in mean cluster size alone or simultaneous adjustment in mean cluster size and number of clusters, and is a flexible alternative to and a useful complement to existing methods. Comparison indicated that we have defined a relative efficiency that is greater than the relative efficiency in the literature under some conditions. Our measure

  18. The relation between energy efficiency and other general objectives from a socioeconomic perspective

    International Nuclear Information System (INIS)

    Ankarhem, Mattias; Braennlund, Runar

    2006-09-01

    An important question in the analysis of energy efficiency programs and their consequences is: How are objectives and instruments defined? E.g. if the objective is reduced carbon dioxide emissions and energy efficiency is the means to reach the objective, then it is not certain that increased energy efficiency will give the result as expected (1). Furthermore, energy efficiency measures will probably be an inefficient way of reaching the goal (2). (1) due to the rebound effects, and (2) since the measures are applied indiscriminately, energy use with only weak couplings to the objective are also affected. Energy efficiency is a partial and relative measure, and does not give much information studied in isolation. It should rather be studied from the perspective of total resource efficiency. Economic policy ought to have the goal of securing a socioeconomic exploitation of all resources (of which energy is one). An instrument working in this direction is internalizing of external effects e.g. through environmental taxes, so that the prices reflect the socioeconomic costs for using the resources. Early foreign studies indicates that a rebound effect exists, usually, however, the technological efficiency potentials can be realized. In a recent study of Swedish conditions, the rebound effect seems to be important. It totally negates the initial effect, at in the end the emissions have increased compared to the starting point. The results show the energy efficiency measures can be in direct conflict with climate and other environmental objectives.

  19. Influence of Impurities on the Radiation Response of the TlBr Semiconductor Crystal

    Directory of Open Access Journals (Sweden)

    Robinson Alves dos Santos

    2017-01-01

    Full Text Available Two commercially available TlBr salts were used as the raw material for crystal growths to be used as radiation detectors. Previously, TlBr salts were purified once, twice, and three times by the repeated Bridgman method. The purification efficiency was evaluated by inductively coupled plasma mass spectroscopy (ICP-MS, after each purification process. A compartmental model was proposed to fit the impurity concentration as a function of the repetition number of the Bridgman growths, as well as determine the segregation coefficients of impurities in the crystals. The crystalline structure, the stoichiometry, and the surface morphology of the crystals were evaluated, systematically, for the crystals grown with different purification numbers. To evaluate the crystal as a radiation semiconductor detector, measurements of its resistivity and gamma-ray spectroscopy were carried out, using 241Am and 133Ba sources. A significant improvement of the radiation response was observed in function of the crystal purity.

  20. Expanding of FOV of NaI(Tl) gamma camera detectors-Is it possible?

    International Nuclear Information System (INIS)

    Gayshan, Vadim L.; Gektin, A.V.; Boyarintsev, A.; Pedash, V.

    2006-01-01

    Every gamma camera detector used for medical imaging of conventional design faces the problem of distorted or no information readout at the areas closer to the edge of detectors. Obtaining position and energy information becomes almost impossible at distance 0-12 of PMT size from the edge. Therefore, in some designs were proposed losing of edge energy resolution while improving in spatial uniformity when it comes to imaging at the edges. This work is dedicated to understanding of the problem, mathematical simulations, practical tests and recommendations to build detectors with larger usable FOV without increasing in dimensions. To study the problem we built the test jig with linear motion source and readout electronics to simulate gamma cameras of PMTs. Based on simulation results the idea of modifying of crystal shape combined with specific light redirection system of baffles was tested and allowed to expand usable FOV. The results are presented and showed that for traditional NaI(Tl) scintillators using 2'' PMT may be possible to obtain relatively good spatial resolution starting from 4-5mm from the edge of a detector. The question of economical efficiency of proposed method is being investigated and a special detector manufacturing technology must be developed to accommodate this. While we believe that achieved results are very important for small size detectors (<20cm) they could be beneficial even for larger detectors used in whole body imaging systems

  1. Color centers in heavily irradiated CsI(Tl) crystals

    International Nuclear Information System (INIS)

    Yakovlev, V.; Meleshko, A.; Trefilova, L.

    2008-01-01

    The absorption and luminescence properties of CsI(Tl) crystals colored by irradiation are studied by the method of the time-resolved spectroscopy. The scheme of the electron transitions in CsI(Tl) crystal is suggested to explain the appearance of the color centers under exposure to the near-UV light. It is established that either of the two types activator color centers holds the charge carrier with opposite sign. The model of the hole Tl 2+ v c - activator color center is suggested. According to the model the positive charge of Tl 2+ ion is compensated by the negative charge of a close cation vacancy v c - . The color center emission reveals in the cathode-luminescence spectrum of the colored CsI(Tl) crystal. The high-dose irradiation of CsI(Tl) crystal results in the reduction of the decay time of the near-thallium self-trapped excitons (STE) emission. The decay kinetics of Tl 2+ v c - emission contains the time components typical for the decay kinetics of near-thallium STE emission. The reason of the observed effects is the energy transfer from the near-thallium STE excitons to the color centers via the inductive-resonant mechanism

  2. Preparation of 199Tl and its labelled compound

    International Nuclear Information System (INIS)

    Zhou Dehai; Guan Changtian; Kuang Anren

    1991-10-01

    Usually, 199 Ti is obtained by the nuclear reaction of 197 Au(α, 2n) 199 Tl. A gold target with 50±0.1 mm in diameter, 0.8 mm in thickness and 99.99% in purity was mounted in a cyclotron beam line. The target was bombarded by α particles with the energy of 25∼27 MeV and the beam current of 15∼20μA. The irradiated gold target was dissolved by aqua regia. Then the saturated aqueous solution of SO 2 was added. The 199 Tl(III)reduced to 199 Tl(I). The deposit of gold was removed. For separation of 199 Tl)I), about 5 mL of raw material solution obtained was transferred to 201 x 8 type anion exchange resin column which had been equilibrated with 4 mol/L HCl. The 199 Tl(I) and Au(III) were desorbed separately with the eluants (90% of aqueous diamide solution,, and 2 mol/L HCL∼5% thiourea) at the flow rate of 0.25 mL/min. After separation, the 10 mL concentrated nitric acid was added to the 199 Tl collected solution to destroy and remove the aqueous diamide solution, then 4 mol/L HCl was added and heated up to remove NO 3 - . The TlCl injection with pH = 5 was made up by using physiological saline. After filtering the 199 TlCl injection was sterilized at 137.3 kPa, 120 deg C about 30 min in an autoclave. The 199 TlCl injection was used in the animal pyrogen, a bacterial, safety, dispensation and myocardial imaging experiments. The good results have been obtained. Now it has undergone clinical experiments

  3. Very low background gamma spectrometer mounted in anti-Compton with NaI(Tl) for the study of glaciers and sediment samples; Spectrometrie gamma a tres bas niveau avec anti-Compton NaI(Tl), pour l`etude des glaciers et des sediments

    Energy Technology Data Exchange (ETDEWEB)

    Pinglot, J.F.; Pourchet, M. [Centre National de la Recherche Scientifique (CNRS), 38 - Grenoble (France). Lab. de Glaciologie

    1994-05-01

    The determination of natural and artificial radioactivities of snow (glaciers, polar ice-caps) or sediment samples (lakes, oceans), takes great benefit with the use of the superior resolution of high purity germanium detector, N type, in a broad energy range( 10 keV up to 1.6 MeV). This detector (relative efficiency: 20%), very low background specified, is mounted in anti-Compton with a 9`x 8` NaI(Tl) scintillator, also with low background. International standards, used with a quantitative software allows the determination of the efficiency curve and the isotopes identification and specific activity. The anti-Compton suppressed spectrometer exhibits a decrease of the background by a factor of ten, without any change in efficiencies. Applications of this spectrometer deal with samples from lake Titicaca and a glacier from Spitsbergen. (authors). 6 figs., 7 refs.

  4. Scintillation response of CsI: Tl crystal under neutron, gamma, alpha particles and beta excitations

    Energy Technology Data Exchange (ETDEWEB)

    Pereira, Maria da Conceicao Costa; Madi Filho, Tufic; Lopes, Valdir Maciel; Berretta, Jose Roberto; Cardenas, Jose Patricio Nahuel, E-mail: macoper@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2015-07-01

    Among the converters of X and gamma radiation in light photons, known as scintillators, the one which is the most efficient emits photons with a wavelength near 400 nm. Particularly, among them, the cesium iodine doped with thallium (CsI:Tl) crystal is that which matches better between the light emission spectrum (peak at 540 nm) and the quantum sensitivity curve of the photodiodes and CCD (Charge Coupled Device). This explains the renewed interest in using this crystal as scintillator. Although the CsI:Tl crystal is commercially available, its local development would give the possibility to obtain it in different geometric configurations and coupling. Moreover, there is a special interest in studying new conditions that will alter the properties of this crystal in order to achieve a optimal level of its functional characteristics. Having an efficient national scintillator with low cost is a strategic opportunity to study the response of a detector applied to different types of radiation. The crystal of cesium iodide activated with thallium (CsI:Tl) has a high gamma detection efficiency per unit volume. In this paper, the CsI:Tl crystal, grown by the vertical Bridgman technique in evacuated silica ampoules and with the purpose of use as radiation detectors, is described. To evaluate the scintillator, measures of the thallium distribution in the crystal volume were taken, with overall efficiency score. The scintillator response was studied through gamma radiation from sources of {sup 137}Cs, {sup 60}Co, {sup 22}Na, {sup 54}Mn, {sup 131}I and {sup 99m}Tc; the beta radiation from source of {sup 90}Sr/{sup 90}Y, alpha particles from {sup 241}Am source and the scintillator response to neutrons from Am/Be source. The energetic resolution for {sup 137}Cs gamma rays (662 keV) was 10%. The results showed the validity of using the CsI:Tl crystal developed in our laboratory, in many applications in the area of radiation detectors. (author)

  5. Dielectric and baric characteristics of TlS single crystal

    Energy Technology Data Exchange (ETDEWEB)

    Mustafaeva, S.N., E-mail: solmust@gmail.com [Institute of Physics, ANAS, G. Javid prosp. 33, Az 1143 Baku (Azerbaijan); Asadov, M.M. [Institute of Chemical Problems, ANAS, G. Javid prosp. 29, Az 1143 Baku (Azerbaijan); Ismailov, A.A. [Institute of Physics, ANAS, G. Javid prosp. 33, Az 1143 Baku (Azerbaijan)

    2014-11-15

    The investigation of the frequency dependences of the dielectric coefficients and ac-conductivity of the TlS single crystals made it possible to elucidate the nature of dielectric loss and the charge transfer mechanism. Moreover, we evaluated the density and energy spread of localized states near the Fermi level, the average hopping time and the average hopping length. It was shown that the dc-conductivity of the TlS single crystals can be controlled by varying the hydrostatic pressure. This has opened up possibilities for using TlS single crystals as active elements of pressure detectors.

  6. Persistent luminescence, TL and OSL characterization of beta irradiated SrAl2O4:Eu2+, Dy3+ combustion synthesized phosphor

    International Nuclear Information System (INIS)

    Zúñiga-Rivera, N.J.; García, R.; Rodríguez-Mijangos, R.; Chernov, V.; Meléndrez, R.; Pedroza-Montero, M.; Barboza-Flores, M.

    2014-01-01

    The persistent luminescence (PLUM), thermoluminescence (TL) and optically stimulated luminescence (OSL) properties of strontium aluminates co-doped with Eu +2 and Dy +3 exposed to beta radiation is reported. The phosphor was synthesized by the combustion synthesis method employing a highly exothermic redox reaction between the metal nitrates [Al(NO 3 ) 3 , Sr(NO 3 ) 2 , Eu(NO 3 ) 3 and Dy(NO 3 ) 3 ] and organic fuel carbohydrazide (CH 6 N 4 O). The long decay PLUM emission, TL and OSL were measured as a function of beta radiation dose. A wide emission band centered at 510 nm (green) related to Eu 2+ ions and lattice defects were observed for the synthesized samples. The presence of a variety of defects and aggregates were responsible for the observed broad 100 °C peaked TL glow curve of the irradiated sample which is composed of several overlapped TL peaks. The existence of multiple trapping levels, with different trapping/detrapping probabilities, is behind the particular features for the PLUM, TL and OSL emissions. We conclude that in the SrAl 2 O 4 :Eu 2+ , Dy 3+ phosphors, the low temperature TL peaked around 30–75 °C is responsible for the PLUM emission and those around 100 °C were related to very stable trapping states which provide suitable radiation storage properties to be used as a PLUM/TL/OSL radiation phosphor

  7. Recent advances in Tl Br, Cd Te and CdZnTe semiconductor radiation detectors: a review

    International Nuclear Information System (INIS)

    Oliveira, Icimone B.

    2011-01-01

    The success in the development of radiation spectrometers operating at room temperature is based on many years of effort on the part of large numbers of workers around the world. These individuals have contributed to the understanding of the fundamental materials issues associated with the growth of semiconductors for this application, the development of device fabrication and processing technology, and advances in low noise electronics and pulse processing. Progress in this field continues at an accelerated pace, as in evidenced by the improvements in detector performance and by the growing number of commercial products. Thus, the last years have been seen continued effort in the development of room temperature compound semiconductors devices. High-Z compound semiconductor detectors has been explored for high energy resolution, high detection efficiency and are of low cost. Compound semiconductors detectors are well suited for addressing needs of demanding applications such as bore hole logging where high operating temperature are encountered. In this work recent developments in semiconductors detectors were reviewed. This review concentrated on thallium bromide (TlBr), cadmium zinc telluride (CdZnTe) and cadmium telluride (CdTe) crystals detectors. TlBr has higher stopping power compared to common semiconductor materials because it has the higher photoelectric and total attenuation coefficients over wide energy range from 100 keV to 1 MeV. CdTe and CdZnTe detectors have several attractive features for detecting X-ray and low energy gamma ray. Their relatively large band gaps lead to a relatively low leakage current and offer an excellent energy resolution at room temperature. A literature survey and bibliography was also included. (author)

  8. Recent advances in Tl Br, Cd Te and CdZnTe semiconductor radiation detectors: a review

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Icimone B. [Universidade Bandeirante (UNIBAN), Sao Paulo, SP (Brazil)

    2011-07-01

    The success in the development of radiation spectrometers operating at room temperature is based on many years of effort on the part of large numbers of workers around the world. These individuals have contributed to the understanding of the fundamental materials issues associated with the growth of semiconductors for this application, the development of device fabrication and processing technology, and advances in low noise electronics and pulse processing. Progress in this field continues at an accelerated pace, as in evidenced by the improvements in detector performance and by the growing number of commercial products. Thus, the last years have been seen continued effort in the development of room temperature compound semiconductors devices. High-Z compound semiconductor detectors has been explored for high energy resolution, high detection efficiency and are of low cost. Compound semiconductors detectors are well suited for addressing needs of demanding applications such as bore hole logging where high operating temperature are encountered. In this work recent developments in semiconductors detectors were reviewed. This review concentrated on thallium bromide (TlBr), cadmium zinc telluride (CdZnTe) and cadmium telluride (CdTe) crystals detectors. TlBr has higher stopping power compared to common semiconductor materials because it has the higher photoelectric and total attenuation coefficients over wide energy range from 100 keV to 1 MeV. CdTe and CdZnTe detectors have several attractive features for detecting X-ray and low energy gamma ray. Their relatively large band gaps lead to a relatively low leakage current and offer an excellent energy resolution at room temperature. A literature survey and bibliography was also included. (author)

  9. Highly accurate determination of relative gamma-ray detection efficiency for Ge detector and its application

    International Nuclear Information System (INIS)

    Miyahara, H.; Mori, C.; Fleming, R.F.; Dewaraja, Y.K.

    1997-01-01

    When quantitative measurements of γ-rays using High-Purity Ge (HPGe) detectors are made for a variety of applications, accurate knowledge of oy-ray detection efficiency is required. The emission rates of γ-rays from sources can be determined quickly in the case that the absolute peak efficiency is calibrated. On the other hand, the relative peak efficiencies can be used for determination of intensity ratios for plural samples and for comparison to the standard source. Thus, both absolute and relative detection efficiencies are important in use of γ-ray detector. The objective of this work is to determine the relative gamma-ray peak detection efficiency for an HPGe detector with the uncertainty approaching 0.1% . We used some nuclides which emit at least two gamma-rays with energies from 700 to 2400 keV for which the relative emission probabilities are known with uncertainties much smaller than 0.1%. The relative peak detection efficiencies were calculated from the measurements of the nuclides, 46 Sc, 48 Sc, 60 Co and 94 Nb, emitting two γ- rays with the emission probabilities of almost unity. It is important that various corrections for the emission probabilities, the cascade summing effect, and the self-absorption are small. A third order polynomial function on both logarithmic scales of energy and efficiency was fitted to the data, and the peak efficiency predicted at certain energy from covariance matrix showed the uncertainty less than 0.5% except for near 700 keV. As an application, the emission probabilities of the 1037.5 and 1212.9 keV γ-rays for 48 Sc were determined using the function of the highly precise relative peak efficiency. Those were 0.9777+0,.00079 and 0.02345+0.00017 for the 1037.5 and 1212.9 keV γ-rays, respectively. The sum of these probabilities is close to unity within the uncertainty which means that the certainties of the results are high and the accuracy has been improved considerably

  10. Solid solutions of thallium in TlGaSe2, TlGaS2, and TlInS2

    International Nuclear Information System (INIS)

    Voroshilov, Yu. V.; Potorii, M.V.; Shevchenko, S.V.

    1986-01-01

    The authors study the nature of the dissolution of thallium in ternary phases. They have synthesized alloys of the stoichiometric compositions TlGaS 2 , TlGaSe 2 , and T1InS 2 , and their solid solutions, maximally enriched in thallium, the compositions of which were Tl /SUB 1.34/ GA /SUB 0.89/ S 2 , Tl /SUB 1.31/ Ga /SUB 0.90/ Se 2 , and Tl /SUB 1.15/ In /SUB 0.95/ S /SUB 2./ . Samples were synthesized from the elemental components of the following purities: gallium of V4 grade; indium of V4 grade; thallium of T1000 grade; selenium of special purity 22-4 grade, and sulfur of special purity garde. The compositions were checked by x-ray-phase-(DRON-0.5) and microstructural-analyses with simultaneous determination of the density and microhardness of the samples. It is found that the lattic parameter increases and the increase in the density and microhardness points to strengthening of the structure during the formation of the solid solutions

  11. Evidences for the Formation of Chromium in the Unusual Oxidation State Cr(IV). I. Chemical Reactivity, Microhomogeneity, and Crystal Structures of the Nonstoichiometric Channel Compounds Tl xCr 5Se 8(0 ≤ x≤ 1)

    Science.gov (United States)

    Bensch, W.; Helmer, O.; Näther, C.

    1996-11-01

    The topotactic redox reaction between TlCr 5Se 8and bromine in acetonitrile leads to the formation of metastable samples with 0 ≤ xtransition metal chalcogenide crystallizing in the TlV 5S 8type structure with a Tl content xtopotactic redox reaction does not follow simple kinetics but is rather explained on the basis of the superposition of at least three different fundamental steps. EDAX investigations conducted on selected single crystals reveal that dependent on the deintercalation temperature, Tl is laterally inhomogeneous distributed along the needle axis which coincides with the crystallographic baxis. A pronounced maximum is observed at the middle of the crystals. In stoichiometric TlCr 5Se 8the detailed analysis of the anisotropic displacement parameters of the Tl atoms reveal that the Tl atoms are displaced from the central position by about 0.26 Å. As a consequence the Tl atoms are coordinated by seven Se atoms in an irregular coordination polyhedron. Since the positions x0 zare related by a center of symmetry they cannot be occupied simultaneously. Hence it must be assumed that TlCr 5Se 8has a domain structure with local symmetry Cm. In the Tl poorer phases the refinement of the Tl atoms at the central position leads to unusual high U22components. The observed microinhomogenity as well as an enhanced mobility and/or static disorder of the Tl atom within the channel may be responsible for this. The value for U11decreases with decreasing Tl content whereas U33is not affected. This observation is indicative for a different displacement of the Tl atoms from the central position. With respect to the possible reaction mechanisms, according to our structural investigations, the oxidation of monovalent Tl to trivalent Tl can be excluded. With decreasing Tl content the lattice parameters exhibit very anisotropic behavior, which is a direct consequence of the large changes of the interatomic Cr-Cr distances. The average as well as the nonbonding Se-Se distances

  12. Improvements in the Tl dosimetry for Radiotherapy; Mejoras en la dosimetria Tl para Radioterapia

    Energy Technology Data Exchange (ETDEWEB)

    Bustos, S.; Velez, G.; Rubio, M. [CEPROCOR. Arenales 230 Juniors Cordoba 5000 (Argentina)

    1998-12-31

    The thermoluminescent dosimetry (TLD) in vivo has been demonstrated to be one of the most reliable for the control of radiotherapeutic treatments, but the delay in the response is the main disadvantage in its applicability. In this work are presented important improvements and it is demonstrated that maintaining the accuracy and reliability of the technique, it is possible to accelerate the response times at a few hours. To realize this work is utilized a lecturer Harshaw 4000, dosemeters LiF-TLD-100 chips (3.1 x 3.1 x 0.89 mm{sup 3}) and rods (1 x 1 x 6 mm{sup 3}). With the implementation of a glow curve analysis program developed in CIEMAT, its obtained a Tl peaks separation in such manner rapid and accurate, by that the thermal treatment of dosemeters may be reduced at one unique annealing pre-irradiation for 1 hr at 400 Centigrade. It is realized a periodical and individual calibration of the TLD and a study of the factors which influencing the ratio Tl signal-dose as linearity, correction by energy, directional response and pride of Tl signal. the results of this study are introducing in a calculation list specially designed and which allows to obtain absorbed dose by TLD starting of the dates (dosimetric peaks area) which appear of the glow curves analysis. The dose is obtained with an accuracy less than 5 %. The dosemeters already irradiated (in vivo) are analysed and informed in only four hours, allowing a greater control of the treatment and a correction of the possible errors for the next session, still in bi fractional treatments. The method implemented results thus accurate, rapid and reliable. (Author)

  13. Network efficiency in autism spectrum disorder and its relation to brain overgrowth

    Directory of Open Access Journals (Sweden)

    John D Lewis

    2013-12-01

    Full Text Available A substantial body of evidence links differences in brain size to differences in brain organization. We have hypothesized that the developmental aspect of this relation plays a role in autism spectrum disorder (ASD, a neurodevelopmental disorder which involves abnormalities in brain growth. Children with ASD have abnormally large brains by the second year of life, and for several years thereafter their brain size can be multiple standard deviations above the norm. The greater conduction delays and cellular costs presumably associated with the longer long-distance connections in these larger brains is thought to influence developmental processes, giving rise to an altered brain organization with less communication between spatially distant regions. This has been supported by computational models and by findings linking greater intra-cranial volume, an index of maximum brain-size during development, to reduced inter-hemispheric connectivity in individuals with ASD. In this paper, we further assess this hypothesis via a whole-brain analysis of network efficiency. We utilize diffusion tractography to estimate the strength and length of the connections between all pairs of cortical regions. We compute the efficiency of communication between each network node and all others, and within local neighborhoods; we then assess the relation of these measures to intra-cranial volume, and the differences in these measures between adults with autism and typical controls. Intra-cranial volume is shown to be inversely related to efficiency for wide-spread regions of cortex. Moreover, the spatial patterns of reductions in efficiency in autism bear a striking resemblance to the regional relationships between efficiency and intra-cranial volume, particularly for local efficiency. The results thus provide further support for the hypothesized link between brain overgrowth in children with autism and the efficiency of the organization of the brain in adults with autism.

  14. Ultrashort-period lateral composition modulation in TlInGaAsN/TlInP structures

    International Nuclear Information System (INIS)

    Ishimaru, Manabu; Tanaka, Yuusuke; Hasegawa, Shigehiko; Asahi, Hajime; Sato, Kazuhisa; Konno, Toyohiko J.

    2009-01-01

    We prepared TlInGaAsN/TlInP quantum well structures using gas source molecular-beam epitaxy and characterized them by means of transmission electron microscopy and scanning transmission electron microscopy. It was found that naturally formed vertical quantum wells, so-called lateral composition modulation (LCM), with a periodicity of ∼1 nm are formed in TlInGaAsN layers. We discuss their formation process using a simple kinetic Ising model for layer-by-layer growth, and point out that the formation of ultrashort-period LCM is a universal phenomenon in most of epitaxially grown III-V semiconductor alloys.

  15. Superdeformation in the Hg-Tl-Pb region

    International Nuclear Information System (INIS)

    Henry, E.A.; Becker, J.A.; Yates, S.W.; Wang, T.F.; Kuhnert, A.; Brinkman, M.J.; Cizewski, J.A.; Deleplanque, M.A.; Diamond, R.M.; Stephens, F.S.; Azaiez, F.; Korten, W.; Draper, J.E.

    1990-10-01

    Superdeformation in the Hg-Tl-Pb region is discussed, with concentration on the experimental results. At least twenty-five superdeformed bands are known in this region, providing much new data to test theoretical calculations. 22 refs., 5 figs

  16. Trace element geochemistry and thermoluminescence (TL) of quartz ...

    African Journals Online (AJOL)

    *

    3Department of Materials Science and Engineering, Tsinghua University, Beijing 100084, China. ... exposure in the recent twenty years, the TL characteristics of the fish otolith have not yet been ..... New discoveries in the study of carp otoliths.

  17. TL dating of vases with elephant ears in Yuan Dynasty

    International Nuclear Information System (INIS)

    Xia Junding; Wang Weida; Leung, P.L.

    2005-01-01

    Thermoluminescence (TL) dating using an activation method in pre-dose technique was described. Three vases in underglaze blue with elephant ears and one vase in underglaze red with elephant ears in Yuan Dynasty were dated by this method. The results show that the TL ages are all less than 100 a B.P., and in which sbc 648 and sbc 649 were imitated in recent years. This method is quick, convenient and reliable for porcelain dating with the age of less than 1000 a B.P.. As a comparison, a porcelain sample with underglaze blue in Yuan Dynasty was dated too, and its TL age is 620 ± 140 B.P.. In addition, some complex factors associated with dating have been discussed and a resolution has been raised, which will help improve the accuracy of TL dating. (authors)

  18. Tl and OSL dosimetry of diamond films CVD pure and unpurified with boron-carbon; Dosimetria Tl y OSL de peliculas de diamante CVD puras e impurificadas con boro-carbono

    Energy Technology Data Exchange (ETDEWEB)

    Melendrez, R.; Pedroza M, M.; Chernov, V.; Ochoa N, J.D.; Bernal, R.; Barboza F, M. [CIF, UNISON, A.P. 5-088, 83190 Hermosillo, Sonora (Mexico); Castaneda, B. [Departamento de Fisica, Universidad de Sonora, Apdo. Postal 1626, Hermosillo, Sonora (Mexico); Goncalves, J.A.N.; Sandonato, G.M. [Laboratorio Associado de Plasma, Instituto Nacional de Pesquisas Espaciais C.P. 515- 12201 -970, Sao Jose dos Campos, SP (Brazil); Cruz Z, E. [Instituto de Ciencias Nucleares, UNAM, Apdo. Postal 70-543, 04510 Mexico D.F. (Mexico); Preciado F, S.; Cruz V, C.; Brown, F. [Departamento de Investigacion en Polimeros y Materiales de la Universidad de Sonora, Apdo. Postal 130, 83000 Hermosillo, Sonora (Mexico); Schreck, M. [Universitaet Augsburg, Institut fuer Physik D-86135 Augsburg (Germany)

    2004-07-01

    The diamond is a material that possesses extreme physical properties, such as its hardness to the radiation, its low chemical reactivity besides its equivalence to the human tissue, which qualify him as an ideal material for radiation dosimetry. In this work, it was studied the thermal and optically stimulated response (Tl and OSL) of polycrystalline diamond films grown by the technique of CVD pure and contaminated with Boron-carbon (B/C) with the intention of characterizing their efficiency like a dosemeter for radiation in a range of 0 - 3000 Gy. For the case of the films without impurities, the Tl curve presents four main peaks, two of them in an interval of temperatures of 150-200 C and other two additional around of 250-400 C. The dependence of the response of integrated Tl and that of OSL always maintained a lineal relationship with the exhibition dose up to 100 Gy. The behavior of the films contaminated with B/C (2000 - 20000 ppm) was established through experiments that involved the signal of OSL and their relationship with the Tl response. It was found that this processes are correlated, since the electrons caught in the traps of low temperature (50 - 250 C) of the Tl they are the electrons that recombining with more probability to provide the signal of OSL. According to these results it is possible to propose the diamond films as a good candidate for dosimetry to, using the traditional technique of Tl so much as well as the but recent of OSL. (Author)

  19. Examining the relation between intangible assets and technical efficiency in the international textile and clothing industry

    NARCIS (Netherlands)

    Kapelko, M.; Oude Lansink, A.G.J.M.

    2014-01-01

    The resource-based view of the firm suggests that intangible assets have a positive impact on firm performance. This study examined the relation between intangible assets and technical efficiency of textile and clothing firms. A double bootstrap data envelopment analysis approach was used to measure

  20. Speciation of Tl(III and Tl(I in hair samples by dispersive liquid–liquid microextraction based on solidification of floating organic droplet prior to flame atomic absorption spectrometry determination

    Directory of Open Access Journals (Sweden)

    S.Z. Mohammadi

    2016-11-01

    Full Text Available Dispersive liquid–liquid microextraction based on solidification of floating organic droplet was successfully used as a sample preparation method prior to flame atomic absorption determination of trace amounts of Tl(III and Tl(I in hair samples. In the proposed method, 1-(2-pyridylazo-2-naphthol, 1-dodecanol and ethanol were used as chelating agent, extraction and dispersive solvent, respectively. Several factors that may be affected in the extraction process, such as type and volume of extraction and disperser solvents, pH, salting out effect, ionic strength and extraction time were studied. Under the optimal conditions, linearity was maintained between 6.0 and 900.0 ng mL−1 for Tl(III. The relative standard deviation for seven replicate determinations of 0.2 μg mL−1 Tl(III was 2.5%. The detection limit based on 3Sb for Tl(III in the original solution was 2.1 ng mL−1. The proposed method has been applied for the determination of trace amounts of thallium in hair samples and satisfactory results were obtained.

  1. Examination of TL and optical absorption in calcite's mineral

    International Nuclear Information System (INIS)

    Sabikoglu, I.; Can, N.

    2009-01-01

    Calcite which is a form of crystalline of the calcium carbonate composes parent material of chalk stone (limestone) and marble. Calcite which presents in various colors also in our country consists of yellow, blue, transparent and green colors. In this study, green calcite mineral which is taken from the region of Ayvalik, was examined of its thermoluminescence (TL) and optical absorption features in different doses. It has been obtained a large TL peak in 179 degree C and absorption peak in 550 mm.

  2. Deformation effects in electronic spectra of the layered semiconductors TlGaS sub 2 , TlGaSe sub 2 and TlInS sub 2

    CERN Document Server

    Allakhverdiev, K R; Suleymanov, R A; Gasanov, N Z

    2003-01-01

    The deformation effects in electronic spectra of the ternary layered semiconductors TlGaS sub 2 , TlGaSe sub 2 and TlInS sub 2 are considered. It is shown that the influence of hydrostatic pressure, thermal expansion and variation of composition in solid solutions on the band gap of the crystals investigated can be described in the framework of one common model of deformation potentials. This model appears to be close to that of layered semiconductors of the A sub 3 B sub 6 group, attesting to the fact that the main principles of formation of band structure in these two groups of layered crystals are the same.

  3. The efficiency of life insurance and family Takaful in Malaysia: Relative efficiency using the stochastic cost frontier analysis

    Science.gov (United States)

    Baharin, Roziana; Isa, Zaidi

    2013-04-01

    This paper focuses on the Stochastic cost Frontier Analysis (SFA) approach, in an attempt to measure the relationship between efficiency and organizational structure for Takaful and insurance operators in Malaysia's dual financial system. This study applied a flexible cost functional form i.e., Fourier Flexible Functional Form, for a sample consisting of 19 firms, chosen between 2002 and 2010, by employing the Battese and Coelli invariant efficiency model. The findings show that on average, there is a significant difference in cost efficiency between the Takaful industry and the insurance industry. It was found that Takaful has lower cost efficiency than conventional insurance, which shows that the organization form has an influence on efficiency. Overall, it was observed that the level of efficiency scores for both life insurance and family Takaful do not vary across time.

  4. The Efficiency of Infants' Exploratory Play Is Related to Longer-Term Cognitive Development

    Science.gov (United States)

    Muentener, Paul; Herrig, Elise; Schulz, Laura

    2018-01-01

    In this longitudinal study we examined the stability of exploratory play in infancy and its relation to cognitive development in early childhood. We assessed infants' (N = 130, mean age at enrollment = 12.02 months, SD = 3.5 months; range: 5–19 months) exploratory play four times over 9 months. Exploratory play was indexed by infants' attention to novelty, inductive generalizations, efficiency of exploration, face preferences, and imitative learning. We assessed cognitive development at the fourth visit for the full sample, and again at age three for a subset of the sample (n = 38). The only measure that was stable over infancy was the efficiency of exploration. Additionally, infants' efficiency score predicted vocabulary size and distinguished at-risk infants recruited from early intervention sites from those not at risk. Follow-up analyses at age three provided additional evidence for the importance of the efficiency measure: more efficient exploration was correlated with higher IQ scores. These results suggest that the efficiency of infants' exploratory play can be informative about longer-term cognitive development. PMID:29904360

  5. Recommendations for the measurement 131I in human thyroid using a detector of NaI(Tl)

    International Nuclear Information System (INIS)

    Puerta Yepes, N.; Rojo, A.M.; Andres, P.A.

    2010-01-01

    The Argentine Total Body Counter Laboratory of the Nuclear Regulatory Authority participated in the last regional intercomparison Exercise organized in the frame of the IAEA Project RLA 9/066 related with in vivo measurements of 131 I in the thyroid. There were identified some difficulties in determining the efficiency and calibration factor (CF) for the 131 I when a source of 133 Ba and a detector of NaI (Tl) are used in the calibration process. Independent measurements were performed for two calibration sources of known activity ( 133 Ba and 131 I) with identical geometry pattern and using a gamma spectrometry system with NaI(Ti) detector. It was found that the region of interest (ROI) which, both in the spectrum of 133 Ba as in the spectrum of 131 I, had the same efficiency. It was determined the activity of the source of 133 Ba , distributed in the intercomparison, and the calibrated source of 131 I using different values of efficiency and FC obtained. It was analyzed the conditions under which the use of 133 Ba as a source of calibration is effective for the measurement of 131 I. (authors) [es

  6. Relative Efficiencies of ASEAN Container Ports based on Data Envelopment Analysis

    Directory of Open Access Journals (Sweden)

    Nikola Kutin

    2017-07-01

    Full Text Available Ports play a critical role in the economies of many countries in the ASEAN region. Efficient ports facilitate a country's imports and exports, and the “relative efficiency” of a port is evaluated based on its efficiency compared to others in its group. This study analyzes the relative efficiencies of 50 ASEAN container ports and terminals. These ports are categorized according to their container handling system and location (those located in a riverbank connected to the sea are called “inland seaports” and those by the seaside are called “seaports”. The traditional output-oriented data envelopment analysis method is applied, and measures of super-efficiency constant returns to scale are estimated in order to compare the units situated on the efficiency frontier. The findings may support port managers in the ASEAN region to make decisions on whether to increase container traffic. In addition, policymakers may consider the evaluation results in deciding whether to improve the trans-ASEAN transport network and ASEAN trade competitiveness.

  7. Relation of managerial efficiency and leadership styles – Empirical study in Hrvatska elektroprivreda d.d.

    Directory of Open Access Journals (Sweden)

    Damir Skansi

    2000-01-01

    Full Text Available The relation of the managerial efficiency and leadership styles are analysed in this paper. We conducted an empirical study in a Croatian power supply company (HEP. The dominant leadership style in HEP is consultational, which the organization, according to postulates of this research, brings closer to the top global companies, considering that the tendencies in leadership styles point to the need for a new generation of leaders which will be essentially different from the traditional manager. We have determined that there is a significant interdependence between leadership styles of HEP’s managers (measured using Likert’s method and the degree of management work efficiency (measured using the adjusted Mott’s technique; the closer the leadership style is to System 4, that is participational, the higher the managerial efficiency is. Also, we have found that there is no significant difference between lower and middle management in HEP, concerning the relation between leadership styles and efficiency. This means that both levels get better grades for its efficiency if they belong to a consultational and participational leadership style.

  8. TL and OSL properties of Mn2+-doped MgGa2O4 phosphor

    Science.gov (United States)

    Luchechko, A.; Zhydachevskyy, Ya; Maraba, D.; Bulur, E.; Ubizskii, S.; Kravets, O.

    2018-04-01

    The oxide MgGa2O4 spinel ceramics doped with Mn2+ ions was synthesized by a solid-state reaction at 1200 °C in air. The activator concentration was equal 0.05 mol% of MnO. Phase purity of the synthesized samples was analyzed by X-ray diffraction technique. This spinel ceramics show efficient green emission in the range from 470 to 550 nm with a maximum at about 505 nm under UV or X-ray excitations, which is due to Mn2+ ions. MgGa2O4: Mn2+ exhibits intense thermoluminescence (TL) and optically stimulated luminescence (OSL) after influence of ionizing radiation. Are complex nature of the TL glow curves is associated with a significant number of structural defects that are responsible for the formation of shallow and deep electron traps. In this work, time-resolved OSL characteristics of the samples exposed to beta particles are reported for the first time. A light from green LED was used for optical stimulation. Obtained TL and OSL results suggest MgGa2O4:Mn2+ as perspective material for further research and possible application in radiation dosimetry.

  9. TL response of citrine samples for high-dose dosimetry

    International Nuclear Information System (INIS)

    Teixeira, Maria Ines; Caldas, Linda V.E.

    2011-01-01

    The possibility of using samples of Brazilian stones as quartz, amethyst, topaz, etc. for high-dose dosimetry has been studied in recent years at IPEN, using the thermoluminescence technique (TL). In this work, the TL properties of citrine samples were studied. They were exposed to different doses of gamma radiation ( 60 Co). The natural citrine stone was extracted from a mine in Minas Gerais state, Brazil; it is a tectosilicate ranked as one of three-dimensional structure, showing clear yellow to golden brown color. The natural citrine stone is classified as quartz (SiO 2 ), and it has a lower symmetry and more compact reticulum. The citrine stone samples were powdered, and the selected grains were mixed with Teflon in the proportion 2 (Teflon):1 (Citrine). The mixture was pressed and sintered for production of Citrine -Teflon pellets of 50 mg. The TL emission curve showed two peaks at 160 deg C and 220 deg C. To remove the TL peak (160 deg C) of the sintered citrine pellet glow curves, different thermal treatments were tested during several time intervals. The TL dose-response curve between 50 Gy and 100 kGy, the reproducibility of TL response and the lower detection dose were obtained. The preliminary results show that citrine may be useful for high-dose dosimetry. (author)

  10. Remote TL and OSL for asteroid and meteorite study

    International Nuclear Information System (INIS)

    Takaki, Shunji; Ikeya, Motoji; Yamanaka, Chihiro

    1997-01-01

    Thermoluminescence (TL) and optically stimulated luminescence (OSL) of the Allende meteorite have been studied using infrared CO 2 laser light as a heat source and He-Ne laser light to excite the material, respectively from a long distance. New techniques of remote TL (R-TL) and remote OSL (R-OSL) have been developed for future remote dating from a long distance in a planetary survey. The upper limits of the distance for R-TL and R-OSL were estimated using the laboratory TL signal of the meteorite peaking at 320 o C: about 400 photons s -1 for the R-TL and 60 photons s -1 for R-OSL at a distance of 1 km using a laser beam with the divergence of 0.1 mrad at powers of 100 and 1 W, respectively. An age limit of 10 5 or 10 6 years due to the signal saturation and the objects heterogeneity, as expected from previous studies, may make the asteroid survey difficult but would still help to investigate the surface activities of icy planets and satellites in outer planet worlds. (author)

  11. Leg 201Tl-SPECT in chronic exertional compartment syndrome

    International Nuclear Information System (INIS)

    Elkadri, N.; Slim, I.; Blondet, C.; Choquet, Ph.; Constantinesco, A.; Lecocq, J.

    2004-01-01

    Leg 201 Tl-SPECT in chronic exertional compartment syndrome Background: The chronic exertional compartment syndrome is one of the most frequent origins regarding leg pain due to sport training. The diagnosis can be established by invasive compartment pressure measurement. The aim of this study is to evaluate the role that could have 201 Tl-SPECT for patients with suspicion of compartment syndrome. Patients and methods: 51 leg 201 Tl-SPECT exams were performed (exercise - and rest without reinjection) in 49 patients; 28 had compartment syndrome confirmed by pressure measurement. About 100 MBq of 201 Tl were injected during exercise, when pain appeared or at least after 25 minutes exercise. We studied mean percentages of level uptake for each compartment, referred to the maximal uptake of both legs. Results: 47 compartments were concerned by compartment syndrome and 361 compartments were not. Scintigraphic patterns in compartments are reversible ischaemia (45%), uptake stability (36%) or reverse redistribution (19%); these patterns are not linked to compartment syndrome. However, there is a significant difference of rest 201 Tl level uptake between compartments with and without compartment syndrome and a significant correlation between muscular pressure measurement and rest level uptake. Conclusion: 201 Tl-SPECT shows that only ischaemia does not explain compartment syndrome. Moreover, it allows to predict pressure variation during exercise but it does not offer any interest in order to select patients for muscular invasive pressure measurement. (author)

  12. $\\alpha$-decay study of $^{182,184}$Tl

    CERN Document Server

    Van Beveren, C; Barzakh, A E; Cocolios, T E; de Groote, R P; Fedorov, D; Fedosseev, V N; Ferrer, R; Ghys, L; Huyse, M; Köster, U; Lane, J; Liberati, V; Lynch, K M; Marsh, B A; Molkanov, P L; Procter, T J; Rapisarda, E; Sandhu, K; Seliverstov, M D; Van Duppen, P; Venhart, M; Veselský, M

    2016-01-01

    α -decay spectroscopy of 182,184 Tl has been performed at the CERN isotope separator on-line ( ISOLDE ) facility. New fi ne-structure α decays have been observed for both isotopes. α -decay branching ratios of 0.089 ( 19 ) %, 0.047 ( 6 ) % and 1.22 ( 30 ) % have been deduced for the ( 10 − ) , ( 7 + ) and ( 2 − ) states respectively in 184 Tl and a lower limit of 0.49% for the α -decay branching ratio of 182 Tl. A new half-life of 9.5 ( 2 ) s for the ( 2 − ) state in 184 Tl and 1.9 ( 1 ) s for the low-spin state in 182 Tl has been deduced. Using α – γ coincidence analysis, multiple γ rays were observed de-exciting levels in 178,18 0 Au fed by 182,184 Tl α decays. The γ transitions connecting these low-lying states in 178,18 0 Au are essential to sort the data and possibly identify bands from in- beam studies in these isotopes. Owing to the complex fi ne-structure α decays and limited knowledge about the structure of the daughter nuclei, only partial level schemes could be constructed for bot...

  13. Determination of kinetic parameters in Tl dosemeters of LiF: Mg, Cu, P + PTFE developed in the ININ; Determinacion de parametros cineticos en dosimetros Tl de LiF: Mg, Cu, P + PTFE desarrollados en el ININ

    Energy Technology Data Exchange (ETDEWEB)

    Basurto G, B.S

    2002-07-01

    The objective of this work, is the one of determining the kinetic parameters of the dosemeter of LiF: Mg, Cu, P + Ptfe; starting from the curves Tl obtained at being irradiated with alpha radiation ({alpha}), beta ({beta}) and gamma ({gamma}). As like to compare its sensitivity with each radiation type, considering the sensitivity of the TLD-100 as the unit. In the Chapter 1, the fundamental structure of the matter is described, making emphasis in the different radiation types, and their interaction with this. In the Chapter 2, the units are described but used in the dosimetry of the radiation. In the Chapter 3, the basic concepts of the phenomenon of Tl are described and those are explained characteristic of the deconvolution method to determine the kinetics of the one phenomenon. In the Chapter 4, the methodology is detailed that was used in the elaboration of this thesis work, describing the material Tl that were considered like reference, as well as the sources of ionizing radiation, with those that the dosemeters were irradiated and the equipment in the one that the curves Tl was obtained. Reference is made to the software used to carry out the deconvolution of the curves Tl that were obtained in the one experimental development. In the Chapter 5, the obtained results of this study are presented, showing the tables of homogenization of dosemeters and the reading of the same one; they are observed the curves Tl obtained to different radiation doses (alpha, beta and gamma), the intensity Tl in function of the dose. Also they are tabulated, the obtained results in the kinetic parameters of the three different study materials (TLD-100H, USA; TLD-100, USA and LiF: Mg, Cu, P + Ptfe developed in the l.N.l.N). They are analyzed shortly for each material Tl their sensitivity to the ionizing radiation as well as their kinetic parameters. The obtained results showed that the Tl dosemeters of LiF: Mg,Cu,P + Ptfe, they presented a bigger sensitivity that the TLD-100 when

  14. The correlation of fast OSL component with the TL peak at 3250C in quartz of various origins

    International Nuclear Information System (INIS)

    Kitis, G.; Kiyak, N.; Polymeris, G.S.; Tsirliganis, N.C.

    2010-01-01

    The fast component of the optically stimulated luminescence (OSL) signal in quartz is the basic tool for the optical dating. Its relation with the thermoluminescence (TL) glow-peak at about 325 deg. C is well established for naturally irradiated quartz. This relationship is also an important part of a general model for quartz on which many theoretical simulations of various OSL experimental results have been based. In the present work this relationship is systematically investigated in nine quartz samples of different origin. The linearly modulated OSL (LM-OSL) curves of all quartz samples for stimulation time less than 50 s consists of two components discriminated easily by a computerized curve deconvolution (CCD) analysis. By comparing the un-bleached to the respective bleached TL glow-curve, it is found that the system of these two fast OSL components is directly related with only a small portion of the electron traps responsible for the TL glow-peaks in the temperature region 200-400 0 C. By increasing the stimulation times, besides the two fast components, the medium and the slow components are also obtained. The medium and slow components are clearly related with the main body of the electron traps responsible for TL glow-peaks in the same temperature region 200-400 0 C. Despite their different origin all quartz samples show an appreciable homogeneity concerning the number and time position of the individual components, whereas, the relative TL/OSL intensities vary strongly from sample to sample with the integrated TL intensity being generally much less than the integrated OSL intensity.

  15. TL Dating Technique Based on a Trap Model and its Application as a Geochronometer for Granitic Quartz

    International Nuclear Information System (INIS)

    Han, Y.; Li, H.; Tso, Y.W.

    1999-01-01

    A trap model is introduced to describe the behaviours of both thermally sensitive and radiation sensitive TL traps. The former are relatively shallow traps. The latter are deep traps, in which population increases with exposure to alpha dose. Thermal decay of both types of traps at ambient temperature is dependent on the trap lifetimes. A trap's population can be measured as TL sensitivity to a laboratory test dose. The trap model has been supported by observations of age dependent TL signals from granitic quartz samples with different crystallisation ages. The trap lifetimes are from 1.98 x 10 9 to 5.36 x 10 15 years estimated using the isothermal decay experiment with the assumption of first order kinetics. Dating techniques are proposed based on the trap model. For old granites (>400 Ma), ages can be obtained by measuring the total exposed alpha dose using the additive alpha dose method, whereas for young granites (<400 Ma), ages can also be obtained by interpolating the TL sensitivity to a curve of TL sensitivities for known ages. (author)

  16. New aspects of cellular thallium uptake: Tl+-Na+-2Cl--cotransport is the central mechanism of ion uptake

    International Nuclear Information System (INIS)

    Sessler, M.J.; Maul, F.D.; Hoer, G.; Munz, D.L.; Geck, P.

    1986-01-01

    Cellular uptake mechanisms of 201 Tl + were studied in Ehrlich mouse ascites tumor cells. 201 Tl + phases the cell membrane of tumor cells using three transport systems: the ATPase, the Tl + -Na + -2Cl - -cotransport, and the Ca ++ -dependent ion channel. In the case of 201 Tl + the main route for entering the cells was the cotransport, its importance increasing with the age of the cells; in parallel, the ATPase activity was reduced. In contrast, the transport capacities of the ATPase and the cotransport were of the same magnitude in the case of 42 K + and 86 Rb + . This change in ion distribution was not brought about by varying velocity relations but by changing the number of transport systems in the cell membrane. There was no relationship between transport rates and diameters of the ions. 201 Tl + distribution is proportional to that of K + with a higher intracellular concentration of about 30%. Under physiological conditions the cotransport was reversible suggesting the ability to regulate steady state during varying extracellular ion concentrations. Cells and medium were two compartments, kinetically seen. Due to the significant difference of transport capacities between the three systems with the respective ions the term ''potassium-thallium-analogy'' may be misleading as it erroneously assumes identical uptake conditions. (orig.) [de

  17. Relative efficiency within a tax administration: The effects of result improvement

    Directory of Open Access Journals (Sweden)

    Elena Villar Rubio

    2017-03-01

    Full Text Available This paper analyses the Spanish tax administration, evaluating the relative efficiency of each of the regional offices that are its constituent parts via output-oriented two-stage data envelopment analysis. In the study, a total of 47 regional offices were analysed, considering three inputs: 1 current expenditure in goods and services; 2 number of tax returns processed in terms of the two main direct taxes; and, 3 personnel numbers. Revenue resulting from tax assessments was considered as output. The analysis shows that the efficient action of regional offices might have increased by 21.6% the results of the management of this administration.

  18. SoTL Research Fellows: Collaborative Pathfinding through Uncertain Terrain

    Directory of Open Access Journals (Sweden)

    Elizabeth Marquis

    2017-12-01

    Full Text Available From 2014-2016, Scholarship of Teaching and Learning (SoTL Research Fellows at a mid-sized Canadian research-intensive, medical-doctoral university undertook to study their own formation as scholars of teaching and learning, as well as benefits and challenges of their cross-appointment to our central teaching and learning institute from their home academic departments. Findings from surveys and focus groups identified themes such as identity, community, access, transfer, and structural elements (each with benefits and challenges to practice. Our autoethnographic work confirms assertions in the literature about the uneasy relation between SoTL and traditional scholarship, while also bearing out the need for departmental support, and for key interventions along the path from novice to practitioner identity. Some discussion of the ambassador or translator role that can flow from such arrangements is included. De 2014 à 2016, les chercheurs en Avancement des connaissances en enseignement et en apprentissage (ACEA d’une université canadienne médicale-doctorale de taille moyenne ayant un coefficient de recherche élevé ont entrepris une étude portant sur leur propre formation en tant que chercheurs érudits en matière d’enseignement et d’apprentissage, ainsi que sur les avantages et les défis de leur nomination conjointe à notre institut central d’enseignement et d’apprentissage tout en enseignant dans leur propre département universitaire. Les résultats des sondages et des groupes de discussion ont permis d’identifier certains thèmes tels que l’identité, la communauté, l’accès, le transfert, ainsi que des éléments structuraux (chacun présentant des avantages et des défis concernant la pratique. Notre travail autoethnographique confirme les assertions présentes dans la documentation existante concernant la relation difficile qui existe entre l’ACEA et la recherche traditionnelle, tout en tenant compte de la n

  19. Determination of kinetic parameters in Tl dosemeters of LiF: Mg, Cu, P + PTFE developed in the ININ

    International Nuclear Information System (INIS)

    Basurto G, B.S.

    2002-01-01

    The objective of this work, is the one of determining the kinetic parameters of the dosemeter of LiF: Mg, Cu, P + Ptfe; starting from the curves Tl obtained at being irradiated with alpha radiation (α), beta (β) and gamma (γ). As like to compare its sensitivity with each radiation type, considering the sensitivity of the TLD-100 as the unit. In the Chapter 1, the fundamental structure of the matter is described, making emphasis in the different radiation types, and their interaction with this. In the Chapter 2, the units are described but used in the dosimetry of the radiation. In the Chapter 3, the basic concepts of the phenomenon of Tl are described and those are explained characteristic of the deconvolution method to determine the kinetics of the one phenomenon. In the Chapter 4, the methodology is detailed that was used in the elaboration of this thesis work, describing the material Tl that were considered like reference, as well as the sources of ionizing radiation, with those that the dosemeters were irradiated and the equipment in the one that the curves Tl was obtained. Reference is made to the software used to carry out the deconvolution of the curves Tl that were obtained in the one experimental development. In the Chapter 5, the obtained results of this study are presented, showing the tables of homogenization of dosemeters and the reading of the same one; they are observed the curves Tl obtained to different radiation doses (alpha, beta and gamma), the intensity Tl in function of the dose. Also they are tabulated, the obtained results in the kinetic parameters of the three different study materials (TLD-100H, USA; TLD-100, USA and LiF: Mg, Cu, P + Ptfe developed in the l.N.l.N). They are analyzed shortly for each material Tl their sensitivity to the ionizing radiation as well as their kinetic parameters. The obtained results showed that the Tl dosemeters of LiF: Mg,Cu,P + Ptfe, they presented a bigger sensitivity that the TLD-100 when being

  20. An empirical method to measure the relative efficiency of dairy producers using deterministic frontier analysis

    Directory of Open Access Journals (Sweden)

    Shahram RostamPour

    2012-01-01

    Full Text Available The purpose of this paper is to measure the relative efficiencies of various cow husbandries. The proposed model of this paper uses distribution free analysis to measure the performance of different units responsible for taking care of cows. We gather the necessary information of all units including number of cows, amount of internet usage, number of subunits for taking care of cows, amount of forage produced in each province for grazing livestock and average hour per person training courses as independent variables and consider the amount of produced milk as dependent variable. The necessary information are collected from all available units located in different provinces of Iran and the production function is estimated using a linear programming model. The results indicate that the capital city of Iran, Tehran, holds the highest technical efficiency, the lowest efficiency belongs to province of Ilam and other provinces mostly performs poorly.

  1. Tl, Bi, and Pb doping in Ba4BiPb2TlO12-δ

    International Nuclear Information System (INIS)

    Sutto, T.E.; Averill, B.A.

    1992-01-01

    To determine the effects of different 6s metal concentrations on the superconducting nature of Ba 4 BiPb 2 TlO 12-δ , materials produced via four doping schemes were examined: Ba 4 Bi(Pb, Tl) 3 O 12-δ , Ba 4 -(BiPb) 3 TlO 12-δ , Ba 4 (Bi,Tl) 2 Pb 2 O 12-δ , and Ba 4 Bi x Pb 4-2x Tl x O 12-δ . For the parent compound a value of δ = 0.91 was observed, indicating that approximately 1/4 oxygen atom was missing per cubic subsection of the unit cell. For all samples, the symmetry of the parent compound changed from orthorhombic to tetragonal as the system moved away from the ideal composition. This was usually accompanied by the loss of superconductivity, which exhibited a maximum T c of 10.5 K for the parent compound Ba 4 BiPb 2 TlO 12-δ . Also reported are high-temperature magnetic susceptibility results, which are used to determine the effect of metal substitution on the density of states at the Fermi level. For each set of variants on the parent composition, the onset of superconductivity was accompanied by a significant decrease in the size of the Pauli paramagnetic signal. 16 refs., 6 figs

  2. Evaluating the Environmental Dimension of Material Efficiency Strategies Relating to the Circular Economy

    Directory of Open Access Journals (Sweden)

    Stuart Walker

    2018-03-01

    Full Text Available Material efficiency is a key element of new thinking to address the challenges of reducing impacts on the environment and of resource scarcity, whilst at the same time meeting service and functionality demands on materials. Directly related to material efficiency is the concept of the Circular Economy, which is based on the principle of optimising the utility embodied in materials and products through the life-cycle. Although materials such as steel, on account of high recycling rates at end-of-life, are amongst the most ‘circular’ of manufactured materials, significant opportunities for greater material efficiency exist, which are yet to be widely implemented. Life Cycle Assessment (LCA is commonly used to assess the environmental benefits of recovering and recycling materials through the manufacturing supply chain and at end-of-life. Using an example taken from renewable energy generation, this paper explores the correlation between product circularity and the environmental case for strategies designed to improve material efficiency. An LCA-based methodology for accounting for the recovery and reuse of materials from the supply chain and at end-of-life is used as the basis for calculating the carbon footprint benefits of five material efficiency scenarios. The results are compared with a number of proposed material circularity indicators. Two conclusions from this exercise are that (i LCA methodologies based around end-of-life approaches are well placed for quantifying the environmental benefits of material efficiency and circular economy strategies and (ii when applying indicators relating to the circularity of materials these should also be supported by LCA-based studies.

  3. Ab-Initio analysis of TlBr: limiting the ionic current without degrading the electronic one

    Science.gov (United States)

    Rocha Leao, Cedric; Lordi, Vincenzo

    2011-03-01

    Although TlBr in principle presents all the theoretical requirements for making high resolution room temperature radiation detectors, practical applications of TlBr have proven to be nonviable due to the polarization that is observed in the crystal after relatively short periods of operation. This polarization, that is believed to be caused by accumulation of oppositely charged ionic species at the ends of the crystal, results in an electric field that opposes that of the applied bias, counter-acting its effect. In this work, we use state of the art quantum modeling to benchmark the theoretical limits for the performance of TlBr as a radiation detector, showing that the best experimental reports demonstrate near-ideal electronic characteristics. We then propose a model to inhibit the detrimental ionic current in the material without impacting the excellent properties of the electronic current. Prepared by LLNL under Contract DE-AC52-07NA27344.

  4. The combined application of PIXE analysis and thermoluminescence (TL) dating for elucidating the origin of iron manufacturing in Japan

    International Nuclear Information System (INIS)

    Hagihara, N.; Miono, S.; Chengzhi, Z.; Nakayama, Y.; Hanamoto, K.; Manabe, S.

    1999-01-01

    For elucidating the origin of iron manufacturing in Japan, the usefulness of PIXE analysis was reconfirmed and a new technique of thermoluminescence (TL) dating was applied. Through reproducing experiments of iron manufacturing and forging, PIXE analysis was tested for classifying the iron slag produced from these two different process. The TL dating method was improved for experiments with the iron manufacturing furnace, burnt at high temperature (about 1300 K) and irradiated with relatively low dose. Utilizing PIXE analysis, the iron manufacturing furnace can be distinguished from the older forging furnace used for the imported iron plate. Adopting TL dating, the oldest iron manufacturing furnace can be found out. Some ancient samples in Japan were used as a test of this combined application, and the results were positive, thus proving the suitability of the method

  5. Direct and indirect signal detection of 122 keV photons with a novel detector combining a pnCCD and a CsI(Tl) scintillator

    Energy Technology Data Exchange (ETDEWEB)

    Schlosser, D.M., E-mail: dieter.schlosser@pnsensor.de [PNSensor GmbH, Sckellstraße 3, 81667 München (Germany); Huth, M.; Hartmann, R. [PNSensor GmbH, Sckellstraße 3, 81667 München (Germany); Abboud, A.; Send, S. [Universität Siegen, Walter-Flex-Straße 3, 57072 Siegen (Germany); Conka-Nurdan, T. [Türkisch-Deutsche Universität, Sakinkaya Cad. 86, Beykoz, 34820 Istanbul (Turkey); Shokr, M.; Pietsch, U. [Universität Siegen, Walter-Flex-Straße 3, 57072 Siegen (Germany); Strüder, L. [PNSensor GmbH, Sckellstraße 3, 81667 München (Germany); Universität Siegen, Walter-Flex-Straße 3, 57072 Siegen (Germany)

    2016-01-01

    By combining a low noise fully depleted pnCCD detector with a CsI(Tl) scintillator, an energy-dispersive area detector can be realized with a high quantum efficiency (QE) in the range from below 1 keV to above 100 keV. In direct detection mode the pnCCD exhibits a relative energy resolution of 1% at 122 keV and spatial resolution of less than 75 µm, the pixel size of the pnCCD. In the indirect detection mode, i.e. conversion of the incoming X-rays in the scintillator, the measured energy resolution was about 9–13% at 122 keV, depending on the depth of interaction in the scintillator, while the position resolution, extracted with the help of simulations, was 30 µm only. We show simulated data for incident photons of 122 keV and compare the various interaction processes and relevant physical parameters to experimental results obtained with a radioactive {sup 57}Co source. - Highlights: • Position and energy resolving pnCCD+CsI(Tl) detector for energies from 1-150 keV • Detection in the pnCCD (122keV): 1% energy and <75µm spatial resolution • Detection in the scintillator (122keV): 9-12% energy and ~30µm spatial resolution.

  6. The Onsager reciprocity relation and generalized efficiency of a thermal Brownian motor

    International Nuclear Information System (INIS)

    Tian-Fu, Gao; Jin-Can, Chen; Yue, Zhang

    2009-01-01

    Based on a general model of Brownian motors, the Onsager coefficients and generalized efficiency of a thermal Brownian motor are calculated analytically. It is found that the Onsager reciprocity relation holds and the Onsager coefficients are not affected by the kinetic energy change due to the particle's motion. Only when the heat leak in the system is negligible can the determinant of the Onsager matrix vanish. Moreover, the influence of the main parameters characterizing the model on the generalized efficiency of the Brownian motor is discussed in detail. The characteristic curves of the generalized efficiency varying with these parameters are presented, and the maximum generalized efficiency and the corresponding optimum parameters are determined. The results obtained here are of general significance. They are used to analyze the performance characteristics of the Brownian motors operating in the three interesting cases with zero heat leak, zero average drift velocity or a linear response relation, so that some important conclusions in current references are directly included in some limit cases of the present paper. (general)

  7. Diagnostic and corrective procedures for TL analysis using the pre-dose technique

    International Nuclear Information System (INIS)

    Haskell, E.H.

    1985-01-01

    The high sensitivity of the pre-dose TL technique using fired quartz grains with relatively low doses makes it the only TL technique that is generally suitable for retrospective environmental dosimetry. The use of this technique for dose measurements of less than 0.2 Gy has been the focus of research at the Utah laboratory, while the extension of the useful range of the pre-dose technique to doses in excess of 5 Gy has been the aim of the Durham laboratory. Certain characteristics of the pre-dose phenomenon, if not properly diagnosed, can lead to erroneous dose estimates at both extremes. This paper describes the procedures used at both laboratories to diagnose such problems and recently developed methods for their circumvention. (author)

  8. TL, OSL and C-14 dating results of the sediments and bricks from mummified nuns' grave

    International Nuclear Information System (INIS)

    Tudela, Diego R.G.; Tatumi, Sonia H.; Yee, Marcio; Brito, Silvio L.M.

    2012-01-01

    This paper presents the results of TL and OSL dating of soil and fragments of bricks from a grave, which was occupied by two mummified nuns, found at 'Luz' Monastery, located in the state of Sao Paulo, Brazil. The TL and OSL ages were compared to C-14 dating ones obtained from bone collagens of the mummies. The majority of the ages is related to the eighteenth century. The gamma-ray spectroscopy was used to evaluate natural radioisotope concentrations in the samples, and by using these concentrations the annual dose rates, from 3.0 to 5.3 Gy/kyr, were obtained. Neutron activation analysis was performed and the radioisotope contents results are in agreement with those obtained by gamma-ray spectroscopy. The contents of U, Th and Ce elements were higher than those found in usual sediments. (author)

  9. Comparative study of 201Tl reinjection tomography and combined use of 13N-ammonia and 18F-fluorodeoxyglucose positron emission tomography for detection of viable myocardium

    International Nuclear Information System (INIS)

    Wang Lijuan; Qi Guoxian; Hu Jian

    2001-01-01

    Objective: To compare the clinical value of 201 Tl reinjection tomography and combined use of 13 N-ammonia (NH 3 ) regional myocardial perfusion and 18 F-fluorodeoxyglucose (FDG) positron emission tomography transfer function and for the myocardium. Methods: The authors performed exercise 201 Tl SPECT (Tl SPECT) on 20 patients with myocardial infarction and obtained standard 201 Tl exercise-redistribution images. 201 Tl was reinjected immediately after redistribution study, and the images were then acquired as also. The 20 patients also underwent PET imaging with 13 N-NH 3 and 18 F-FDG (NH 3 -FDG PET) within one week of the above study. Vertical and horizontal long axis cuts were divided into nine segments, and uptakes of radioisotope were evaluated into four classes visually (Defect score, DS) (0:normal uptake, 3:severely reduced). Quantitative evaluation was performed on the vertical and horizontal long axis cuts of 201 Tl redistribution, reinjection and FDG PET images using regions of interest. The relative myocardial 201 Tl uptake and 18 F-FDG uptake (% ID) were expressed as the percentage of this reference region accounted for of the maximal counts. Results: In 48 segments identified as viable by the NH 3 -FDG PET images, 45 (93.8%) segments were also identified as viable by the 201 Tl redistribution imaging. Of 24 segments with severe irreversible defects on the 201 Tl redistribution imaging, 87.5% of the segments were concordantly confirmed by 201 Tl reinjection and NH 3 -FDG PET images with 37.5% identified as viable and 50% identified as scar. There was no significant difference in the average % ID, furthermore, regression analysis revealed a high positive correlation in the segmental % ID between 201 Tl reinjection and FDG PET images in the 61 segments with myocardial infarction (r = 0.722). Conclusions: The results show that 201 Tl reinjection tomography is of similar accuracy with NH 3 -FDG PET for detection of viable myocardium and possess important

  10. Relative dose efficiencies of antiscatter grids and air gaps in pediatric radiography

    International Nuclear Information System (INIS)

    McDaniel, D.L.; Cohen, G.; Wagner, L.K.; Robinson, L.H.

    1984-01-01

    The relative dose efficiencies (RDE) of various antiscatter grids and air gaps were determined for conditions simulating those found in pediatric radiography, using phantoms representing a newborn child, a 5-yr-old and a 10-yr-old child. Our data indicate than an air gap is best for the newborn, due to the low levels of scatter. The 8:1 fiber grid or 15.2-cm air gap without a grid can improve dose efficiency (DE) for the 5-yr-old child by 20%--25% relative to the 3.3-cm air gap and no-grid technique, while for the 10-yr-old child, DE can be improved by 40% with an 8:1 fiber grid

  11. The relative efficiency of Iranian's rural traffic police: a three-stage DEA model.

    Science.gov (United States)

    Rahimi, Habibollah; Soori, Hamid; Nazari, Seyed Saeed Hashemi; Motevalian, Seyed Abbas; Azar, Adel; Momeni, Eskandar; Javartani, Mehdi

    2017-10-13

    Road traffic Injuries (RTIs) as a health problem imposes governments to implement different interventions. Target achievement in this issue required effective and efficient measures. Efficiency evaluation of traffic police as one of the responsible administrators is necessary for resource management. Therefore, this study conducted to measure Iran's rural traffic police efficiency. This was an ecological study. To obtain pure efficiency score, three-stage DEA model was conducted with seven inputs and three output variables. At the first stage, crude efficiency score was measured with BCC-O model. Next, to extract the effects of socioeconomic, demographic, traffic count and road infrastructure as the environmental variables and statistical noise, the Stochastic Frontier Analysis (SFA) model was applied and the output values were modified according to similar environment and statistical noise conditions. Then, the pure efficiency score was measured using modified outputs and BCC-O model. In total, the efficiency score of 198 police stations from 24 provinces of 31 provinces were measured. The annual means (standard deviation) of damage, injury and fatal accidents were 247.7 (258.4), 184.9 (176.9), and 28.7 (19.5), respectively. Input averages were 5.9 (3.0) patrol teams, 0.5% (0.2) manpower proportions, 7.5 (2.9) patrol cars, 0.5 (1.3) motorcycles, 77,279.1 (46,794.7) penalties, 90.9 (2.8) cultural and educational activity score, 0.7 (2.4) speed cameras. The SFA model showed non-significant differences between police station performances and the most differences attributed to the environmental and random error. One-way main road, by road, traffic count and the number of household owning motorcycle had significant positive relations with inefficiency score. The length of freeway/highway and literacy rate variables had negative relations, significantly. Pure efficiency score was with mean of 0.95 and SD of 0.09. Iran's traffic police has potential opportunity to reduce

  12. Productivity Change, Technical Progress, and Relative Efficiency Change in the Public Accounting Industry

    OpenAIRE

    Rajiv D. Banker; Hsihui Chang; Ram Natarajan

    2005-01-01

    We present evidence on components of productivity change in the public accounting industry toward the end of the 20th century. Using revenue and human resource data from 64 of the 100 largest public accounting firms in the United States for the 1995--1999 period, we analyze productivity change, technical progress, and relative efficiency change over time. The average public accounting firm experienced a productivity growth of 9.5% between 1995 and 1999. We find support for the hypothesis that...

  13. The relative efficiency of market-based environmental policy instruments with imperfect compliance

    OpenAIRE

    Rousseau, Sandra; Proost, Stef

    2004-01-01

    This paper examines to what extent incomplete compliance of environmental regulation mitigates the distortions caused by pre-existing labour taxes. We study the relative cost efficiency of three market-based instruments: emission taxes, tradable permits and output taxes. In a first-best setting and given that monitoring and enforcement is costless, we find that the same utility levels can be reached with and without incomplete compliance. However, allowing for violations makes the policy i...

  14. Drought effect on weaning weight and efficiency relative to cow size in semiarid rangeland.

    Science.gov (United States)

    Scasta, J D; Henderson, L; Smith, T

    2015-12-01

    Cow size has been suggested to be an important consideration for selecting cattle to match their production environment. Over the last several decades, the trend in genetic selection for maximum growth has led to gradual increases in beef cow size. An unrelated trend during this same period in the western United States has been an increase in temperature, drought frequency, and drought severity. Due to the potential influence of the increasing cow size trend on nutritional maintenance costs and production, we assessed the effect of cow size on weaning weight and efficiency in relation to drought on a semiarid high-elevation ranch in Wyoming. This study addresses a lack of empirical studies on the interaction between cow size and drought. We measured calf weaning weights of 80 Angus × Gelbvieh cows from 2011 to 2014 and assessed how drought affected weaning weights, efficiency (considered as calf weight relative to cow weight), intake requirements, and potential herd sizes relative to cow size. We stratified cows into 5 weight classes (453, 498, 544, 589, and 634 kg) as a proxy for cow size and adjusted weaning weights to a 210-d calf sex adjusted value. Cow size was a significant factor every year, with different cow sizes having advantages or disadvantages different years relative to weaning weight. However, efficiency for the smallest cows (453 kg) was always greater than efficiency for largest cows (634 kg; cows was greater in the driest year (0.41 ± 0.02) than efficiency of the largest cows in the wettest years (0.37 ± 0.01). The change in efficiency (ΔE) between wet and dry years was 0.18 for the smallest cow size and 0.02 for the largest cow size, and ΔE decreased as cow size increased. This is an indication of the ability of smaller cows to lower maintenance requirements in response to changes in the production environment but with optimal upside potential when conditions are favorable. These results indicate large cows (589 to 634 kg) do not maximize

  15. Development of a coincidence circuit with nanosecond resolving time for NaI(Tl) scintillator pulses

    International Nuclear Information System (INIS)

    Ripon, R.; Coussot, G.

    1969-01-01

    The principle and the details of a slow-fast type coincidence circuit for pulses delivered by Nal(Tl) scintillators are presented. Thanks to a voluntary limitation of the analysis band (150 keV to 1 MeV) an excellent stability is obtained with respect to thermal drifts. The resolving time which has been adopted, 4 ns with 100 per cent efficiency, is quite sufficient for the projected experiment but does not represent the optimum performance of which the circuit is capable [fr

  16. Predictive values of early rest/24 hour delay Tl-201 perfusion SPECT for wall motion improvement in patients with acute myocardial infarction after reperfusion

    International Nuclear Information System (INIS)

    Hyun, In Young; Kwan, June

    1998-01-01

    We studied early rest/24 hour delay Tl-201 perfusion SPECT for prediction of wall motion improvement after reperfusion in patients with acute myocardial infarction. Among 17 patients (male/female=11/6, age: 59±13) with acute myocardial infarction, 15 patients were treated with percutaneous transcoronary angioplasty (direct:2, delay:11) and intravenous urokinase (2). Spontaneous resolution occurred in infarct related arteries of 2 patients. We confirmed TIMI 3 flow of infarct-related artery after reperfusion in all patients with coronary angiography. We performed rest Tl-201 perfusion SPECT less then 6 hours after reperfusion and delay Tl-201 perfusion SPECT next day. Tl-201 uptake was visually graded as 4 point score from normal (0) to severe defect (3). Rest Tl-201 uptake ≤2 or combination of rest Tl-201 uptake ≤2 or late reversibility were considered to be viable. Myocardial wall motion was graded as 5 point score from normal (1) to dyskinesia (5). Myocardial wall motion was considered to be improved when a segment showed an improvement ≥1 grade in follow up echo compared with the baseline values. Among 98 segments with wall motion abnormality, the severity of myocardial wall motion decrease was as follow: mild hypokinesia: 18/98 (18%), severe hypokinesia: 28/98 (29%), akinesia: 51/98 (52%), dyskinesia: 1/98 (1%). The wall motion improved in 85%. Redistribution (13%), and reverse redistribution (4%) were observed in 24 hour delay SPECT. Positive predictive value (PPV) and negative predictive value (NPV) of combination of late reversibility and rest Tl-201uptake were 99%, and 54%.PPV and NPV of rest Tl-201 uptake were 100% and 52% respectively. Predictive values of comibination of rest Tl-201 uptake and late reversibility were not significantly different compared with predictive values of rest Tl-201 uptake only. We conclude that early Tl-201 perfusion SPECT predict myocardial wall motion improvement with excellent positive but relatively low negative

  17. Benchmarking NaI(Tl) Electron Energy Resolution Measurements

    International Nuclear Information System (INIS)

    Mengesha, Wondwosen; Valentine, J D.

    2002-01-01

    A technique for validating electron energy resolution results measured using the modified Compton coincidence technique (MCCT) has been developed. This technique relies on comparing measured gamma-ray energy resolution with calculated values that were determined using the measured electron energy resolution results. These gamma-ray energy resolution calculations were based on Monte Carlo photon transport simulations, the measured NaI(Tl) electron response, a simplified cascade sequence, and the measured electron energy resolution results. To demonstrate this technique, MCCT-measured NaI(Tl) electron energy resolution results were used along with measured gamma-ray energy resolution results from the same NaI(Tl) crystal. Agreement to within 5% was observed for all energies considered between the calculated and measured gamma-ray energy resolution results for the NaI(Tl) crystal characterized. The calculated gamma-ray energy resolution results were also compared with previously published gamma-ray energy resolution measurements with good agreement (<10%). In addition to describing the validation technique that was developed in this study and the results, a brief review of the electron energy resolution measurements made using the MCCT is provided. Based on the results of this study, it is believed that the MCCT-measured electron energy resolution results are reliable. Thus, the MCCT and this validation technique can be used in the future to characterize the electron energy resolution of other scintillators and to determine NaI(Tl) intrinsic energy resolution

  18. Comparison measure of natural radioactivity in environment specimen using HPGe and NaI(Tl) γ-ray spectrometer

    International Nuclear Information System (INIS)

    Zhou Chunlin; Han Feng; Li Tiantuo; Ma Wenyan; Di Yuming; Guo Huiping; Wu Yuelei

    2000-01-01

    The author reports the comparison results on natural radioactive nuclide contents of soil specimen from an uranium diggings with HPGe and NaI(Tl) γ-ray spectrometer. Relative method and athwart matrix method are used to analyze natural radioactive nuclide contents in samples of soil. The results are compared and are proven to be in accordance with each other

  19. Experimental studies on using silicon photodiode as read-out component of CsI(Tl) crystal

    International Nuclear Information System (INIS)

    He Jingtang; Chen Duanbao; Li Zuhao; Mao Yufang; Dong Xiaoli

    1996-01-01

    Experimental studies on using silicon photodiode as the read-out component of CsI(Tl) crystal are reported. The read-out properties of two different types of silicon photodiode produced by Hamamatsu were measured, including relations between energy resolution and bias, shaping time, sensitive area of photodiode and the dimension of the crystal

  20. Effects of film thickness on scintillation characteristics of columnar CsI:Tl films exposed to high gamma radiation doses

    Energy Technology Data Exchange (ETDEWEB)

    Shinde, Seema; Singh, S.G.; Sen, S.; Gadkari, S.C., E-mail: gadkari@barc.gov.in

    2016-02-21

    Oriented columnar films of Tl doped CsI (CsI:Tl) of varying thicknesses from 50 µm to 1000 µm have been deposited on silica glass substrates by a thermal evaporation technique. The SEM micrographs confirmed the columnar structure of the film while the powder X-ray diffraction pattern recorded for the films revealed a preferred orientation of the grown columns along the <200> direction. Effects of high energy gamma exposure up to 1000 Gy on luminescence properties of the films were investigated. Results of radio-luminescence, photo-luminescence and scintillation studies on the films are compared with those of a CsI:Tl single crystal with similar thickness. A possible correlation between the film thicknesses and radiation damage in films has been observed. - Highlights: • CsI:Tl films of different thicknesses deposited for γ and α detection. • Pulse-height spectra found to degrade with increasing thickness. • Radiation damage is found more in films than single crystal of comparable thickness. • Detection efficiency increases for γ while it is invariant for α beyond 50 µm.

  1. Effects of film thickness on scintillation characteristics of columnar CsI:Tl films exposed to high gamma radiation doses

    International Nuclear Information System (INIS)

    Shinde, Seema; Singh, S.G.; Sen, S.; Gadkari, S.C.

    2016-01-01

    Oriented columnar films of Tl doped CsI (CsI:Tl) of varying thicknesses from 50 µm to 1000 µm have been deposited on silica glass substrates by a thermal evaporation technique. The SEM micrographs confirmed the columnar structure of the film while the powder X-ray diffraction pattern recorded for the films revealed a preferred orientation of the grown columns along the direction. Effects of high energy gamma exposure up to 1000 Gy on luminescence properties of the films were investigated. Results of radio-luminescence, photo-luminescence and scintillation studies on the films are compared with those of a CsI:Tl single crystal with similar thickness. A possible correlation between the film thicknesses and radiation damage in films has been observed. - Highlights: • CsI:Tl films of different thicknesses deposited for γ and α detection. • Pulse-height spectra found to degrade with increasing thickness. • Radiation damage is found more in films than single crystal of comparable thickness. • Detection efficiency increases for γ while it is invariant for α beyond 50 µm.

  2. Is there Need for more Transparency and Efficiency in Cause-related Marketing?

    Directory of Open Access Journals (Sweden)

    Nina Langen

    2011-02-01

    Full Text Available The popularity of ethical consumption increases. This has motivated firms to increasingly implement Cause-related Marketing (CrM campaigns in Germany. But research reveals that especially German consumers are sceptic with regard to the amount of money spent for the good ‘cause’ by the enterprises. This can be explained by the small share of information provided by CrM campaigns to consumers. In consequence, this can reduce consumers’ willingness to purchase CrM products. Therefore, this study analyses whether the efficiency and transparency of a CrM campaign are important for consumers. The share of money reaching the cause relative to the product price consumers’ pay is taken as a proxy for efficiency while transparency is understood as the open communication of donated amounts on the product by label. A consumer survey conducted in Germany in 2009 reveals that consumers have a great interest in the transparency of a CrM campaign. Furthermore, the study gives evidence that there is a gap between the levels of expected and requested efficiency of CrM donations. Consequently, firms should label the donation amount to meet consumers’ transparency needs. Furthermore, to create a successful CrM campaign companies also have to consider that the amount of money devoted to the good cause is of relevance for consumers.

  3. Nutritional efficiency of alpha-ketoisocaproate relative to leucine, assessed isotopically

    International Nuclear Information System (INIS)

    Kang, C.W.; Walser, M.

    1985-01-01

    The efficiency of alpha-ketoisocaproate as a dietary substitute for leucine was assessed in rats by two techniques: first, the minimal dose of alpha-ketoisocaproate required, as a supplement to a leucine-free diet, to achieve a growth rate as great as animals receiving leucine was found to be between 2.2 and 4.4 times larger. Therefore the nutritional efficiency of alpha-ketoisocaproate lies between 0.23 and 0.46. Second, alpha-[1- 14 C]-ketoisocaproate and [ 3 H]leucine were administered orally and the ratio of 14 C/ 3 H incorporated into the leucine of whole-body protein and fibrin was measured. This ratio, divided by the ratio 14 C/ 3 H injected, was the same in fibrin as in whole-body protein and averaged 0.39. Thus both techniques yield the same value, within the error of measurement, for the relative nutritional efficiency of alpha-ketoisocaproate. The authors also found that alpha-ketoisocaproate feeding at varying dosage did not alter this ratio in whole-body protein, suggesting that neither wide variations in growth rate nor exposure for 10 days to alpha-ketoisocaproate alters the relative rates of utilization (or oxidation) of alpha-ketoisocaproate vs. leucine

  4. Nutritional efficiency of alpha-ketoisocaproate relative to leucine, assessed isotopically

    Energy Technology Data Exchange (ETDEWEB)

    Kang, C.W.; Walser, M.

    1985-10-01

    The efficiency of alpha-ketoisocaproate as a dietary substitute for leucine was assessed in rats by two techniques: first, the minimal dose of alpha-ketoisocaproate required, as a supplement to a leucine-free diet, to achieve a growth rate as great as animals receiving leucine was found to be between 2.2 and 4.4 times larger. Therefore the nutritional efficiency of alpha-ketoisocaproate lies between 0.23 and 0.46. Second, alpha-(1- UC)-ketoisocaproate and (TH)leucine were administered orally and the ratio of UC/TH incorporated into the leucine of whole-body protein and fibrin was measured. This ratio, divided by the ratio UC/TH injected, was the same in fibrin as in whole-body protein and averaged 0.39. Thus both techniques yield the same value, within the error of measurement, for the relative nutritional efficiency of alpha-ketoisocaproate. The authors also found that alpha-ketoisocaproate feeding at varying dosage did not alter this ratio in whole-body protein, suggesting that neither wide variations in growth rate nor exposure for 10 days to alpha-ketoisocaproate alters the relative rates of utilization (or oxidation) of alpha-ketoisocaproate vs. leucine.

  5. Characteristics of dielectric properties and conduction mechanism of TlInS2:Cu single crystals

    Science.gov (United States)

    El-Nahass, M. M.; Ali, H. A. M.; El-Zaidia, E. F. M.

    2013-12-01

    Single crystals of TlInS2:Cu were grown by the modified Bridgman method. The dielectric behavior of TlInS2:Cu was investigated using the impedance spectroscopy technique. The real (ε1), imaginary (ε2) parts of complex dielectric permittivity and ac conductivity were measured in the frequency range (42-2×105) Hz with a variation of temperature in the range from 291 K to 483 K. The impedance data were presented in Nyquist diagrams for different temperatures. The frequency dependence of σtot (ω) follows the Jonscher's universal dynamic law with the relation σtot (ω)=σdc+Aωs, (where s is the frequency exponent). The mechanism of the ac charge transport across the layers of TlInS2:Cu single crystals was referred to the hopping over localized states near the Fermi level. The examined system exhibits temperature dependence of σac (ω), which showed a linear increase with the increase in temperature at different frequencies. Some parameters were calculated as: the density of localized states near the Fermi level, NF, the average time of charge carrier hopping between localized states, τ, and the average hopping distance, R.

  6. Computerized study with /sup 201/Tl of the cold thyroid node

    Energy Technology Data Exchange (ETDEWEB)

    Palermo, F.; Saitta, B.; Coghetto, F.; Tiberio, M.; Caldato, L.

    1982-02-01

    Because of its physical and potassium-metabolic characteristics /sup 201/Tl is more suitable than /sup 131/Cs for radioisotopic studies of the cold thyroid nodule, with the further diagnostic possibility of quantitatively assessing intranodular behaviour for a specific differentiation among different kinds of neoformations. Using a gamma-camera on line with a computer data processing device, sequential scintiscans were recorded for the first 20-30 min after i.v. administration of 15-20 ..mu..Ci/kg of radiothallium; delayed sequences were taken at 40-60 min if intranodular uptake appeared. A quantitative appraisal was made of the differential /sup 201/Tl uptake-ratio between nodule and healthy thyroid tissue (density-index) and the multiparameter analysis of thyroid time/activity curves generated on the relative regions of interest (ROIs). This computerized study, in 120 out of 293 patients submitted to this radiothallium test, has shown a) diagnostic agreement between clinical-histological and radioisotopic findings in 76 out of 79 colloid-cystic or degenerative neoformations, in all 16 malignant and in 23 out of 25 hyperplastic benign nodules; b) significant statistical difference of the density-index in solid versus cystic but not between benign and malignant nodules; c) different /sup 201/Tl kinetics behaviour in different kinds of solid thyroid lesions with a satisfactory statistical difference of the radiothallium nodular dissappearance-index.

  7. Phytotoxicity of thallium (Tl) in culture solution. Pt. 2. Effects of Tl(III) on the growth and heavy metal contents of pea and field bean plants

    Energy Technology Data Exchange (ETDEWEB)

    Pieper, B; Austenfeld, F A

    1985-01-01

    The effects of Tl(NO/sub 3/)/sub 3/ and Tl(III)EDTA on growth and heavy metal contents of pea plants and field bean plants were compared in hydroponic culture experiments. In the presence of Tl(NO/sub 3/)/sub 3/, the essential heavy metals were available to the plants in their ionic forms. When Tl(III)EDTA was present the essential heavy metals were available as chelated complexes. Dry matter production of the pea plants was inhibited to a greater extent by Tl(III)EDTA than by Tl(NO/sub 3/)/sub 3/. The distribution of Tl within the plant was unaffected by the accompanying anion, however an increase of the Tl content of the stems and the leaves was observed in the presence of Tl(III)EDTA. The micronutrients exhibited different interactions with Tl(III). In the presence of increasing concentrations of Tl(NO/sub 3/)/sub 3/ the Mn content of each organ and the Zn content of the roots were lowered, but the Zn content of the stems was increased. Increasing concentrations of Tl(III)EDTA resulted only in a decrease of the Mn content of the roots, but in an increase of the contents of Fe and Mn within the stems, and Fe, Mn, Zn, and Cu within the leaves. The increases may be due to concentration by growth inhibition. In contrast to pea plants, growth of field bean plants was inhibited only by Tl(NO/sub 3/)/sub 3/. The field bean plants retained most of the Tl within the roots independent of the Tl compound in the solution. Chelation of Tl(III) resulted in higher Tl contents of both the roots and the stems, but equal or reduced Tl contents of the leaves. Whereas increasing concentrations of Tl(NO/sub 3/)/sub 3/ reduced the Mn content of each organ as well as the Zn content of the roots and the leaves, Tl(III)EDTA only reduced the Mn content of the roots.

  8. Ab initio calculations of the electron spectrum and density of states of TlFeS{sub 2} and TlFeSe{sub 2} crystals

    Energy Technology Data Exchange (ETDEWEB)

    Ismayilova, N. A., E-mail: ismayilova-narmin-84@mail.ru; Orudjev, H. S.; Jabarov, S. H. [Azerbaijan National Academy of Sciences, Institute of Physics (Azerbaijan)

    2017-04-15

    The results of ab initio calculations of the electron spectrum of TlFeS{sub 2} and TlFeSe{sub 2} crystals in the antiferromagnetic phase are reported. Calculations are carried out in the context of the density functional theory. The origin of the bands of s, p, and d electron states of Tl, Fe, S, and Se atoms is studied. It is established that, in the antiferromagnetic phase, the crystals possess semiconductor properties. The band gaps are found to be 0.05 and 0.34 eV for TlFeS{sub 2} and TlFeSe{sub 2} crystals, respectively.

  9. Stability of Tl-Ba-Ca-Cu-O Superconducting Thin Films

    Energy Technology Data Exchange (ETDEWEB)

    Siegal, M.P.; Overmyer, D.L.; Venturini, E.L.; Padilla, R.R.; Provencio, P.N.

    1999-08-23

    We report the stability of TlBa{sub 2}CaCu{sub 2}O{sub 7} (Tl-1212) and Tl{sub 2}Ba{sub 2}CaCu{sub 2}O{sub 8} (T1-2212) thin films and by inference, the stability of TlBa{sub 2}Ca{sub 2}Cu{sub 3}O{sub 9} (Tl-1223) and Tl{sub 2}Ba{sub 2}Ca{sub 2}Cu{sub 3}O{sub 10} (Tl-2223) thin films, under a variety of conditions. In general, we observe that the stability behavior of the single Tl-O layer materials (Tl-1212 and Tl-1223)are similar and the double Tl-O layer materials (Tl-2212 and Tl-2223) are similar. All films are stable with repeated thermal cycling to cryogenic temperatures. Films are also stable in acetone and methanol. Moisture degrades film quality rapidly, especially in the form of vapor. Tl-1212 is more sensitive to vapor than Tl-2212. These materials are stable to high temperatures in either N{sub 2}, similar to vacuum for the cuprates, and O{sub 2} ambients. While total degradation of properties (superconducting and structural) occur at the same temperatures for all phases, 600 C in N{sub 2} and 700 C in O{sub 2}, the onset of degradation occurs at somewhat lower temperatures for Tl-1212 than for Tl-2212 films. In all cases, sample degradation is associated with Tl depletion from the films.

  10. Measuring the relative efficiencies of automated telling machines and point of sales

    Directory of Open Access Journals (Sweden)

    Sara Farajzadeh

    2015-11-01

    Full Text Available During the past few years, many people have been interested in purchasing goods and services via point of sales (POS. They have also wished to pay their bills, withdraw cash or transfer funds using automated telling machines (ATMs. These two facilities help banks’ customers carry less amount of cash and do their daily banking activities any time even when the banks are closed. This paper presents an empirical investigation to measure the relative efficiency of nearly 600 POS and ATM units associated with Bank Melli Iran located in city of Tehran, Iran. Using data envelopment analysis, the study has disclosed that only small portions of POS and ATM are working efficiently.

  11. EPR and TL correlation in some powdered Greek white marbles

    International Nuclear Information System (INIS)

    Baieetto, Vanessa; Villeneuve, Gerard; Guibert, Pierre; Schvoerer, Max

    2000-01-01

    Thermoluminescence of white powdered marble samples, chosen to display different EPR spectra, were studied. Two peaks at 280 deg. C and 360 deg. C can be observed among the TL glow curves while the EPR spectra exhibit two signals: the A signal with g perp =2.0038 and g par =2.0024 due to the SO - 3 centre and the B one with g 1 =2.0005; g 2 =2.0001; g 3 =1.9998 due to mechanical powder reduction (drilling). Owing to heating and simultaneous experiments, a correlation have been established: the 280 deg. C TL peak is associated to the A signal and thus to the SO - 3 centre and the 360 deg. C TL peak is caused by mechanical treatment corresponding to the B EPR signal

  12. EPR and TL correlation in some powdered Greek white marbles

    Energy Technology Data Exchange (ETDEWEB)

    Baieetto, Vanessa E-mail: crpaa@montaigne.u-bordeaux.fr; Villeneuve, Gerard; Guibert, Pierre; Schvoerer, Max

    2000-02-01

    Thermoluminescence of white powdered marble samples, chosen to display different EPR spectra, were studied. Two peaks at 280 deg. C and 360 deg. C can be observed among the TL glow curves while the EPR spectra exhibit two signals: the A signal with g{sub perp}=2.0038 and g{sub par} =2.0024 due to the SO{sup -}{sub 3} centre and the B one with g{sub 1}=2.0005; g{sub 2}=2.0001; g{sub 3}=1.9998 due to mechanical powder reduction (drilling). Owing to heating and simultaneous experiments, a correlation have been established: the 280 deg. C TL peak is associated to the A signal and thus to the SO{sup -}{sub 3} centre and the 360 deg. C TL peak is caused by mechanical treatment corresponding to the B EPR signal.

  13. EPR and TL correlation in some powdered Greek white marbles.

    Science.gov (United States)

    Baïetto, V; Villeneuve, G; Guibert, P; Schvoerer, M

    2000-02-01

    Thermoluminescence of white powdered marble samples, chosen to display different EPR spectra, were studied. Two peaks at 280 degrees C and 360 degrees C can be observed among the TL glow curves while the EPR spectra exhibit two signals: the A signal with g perpendicular = 2.0038 and g parallel = 2.0024 due to the SO3- centre and the B one with g1 = 2.0005; g2 = 2.0001; g3 = 1.9998 due to mechanical powder reduction (drilling). Owing to heating and simultaneous experiments, a correlation have been established: the 280 degrees C TL peak is associated to the A signal and thus to the SO3- centre and the 360 degrees C TL peak is caused by mechanical treatment corresponding to the B EPR signal.

  14. Stability of detecting system using NaI(Tl)

    International Nuclear Information System (INIS)

    Zhuo Yunshang; Lei Zhangyun; Zen Yu; Gong Hua

    1996-01-01

    A detecting system using NaI(Tl) is widely used in research and industry of nuclear science and other fields. For providing the high accuracy and working well under inclement environment, the stability of detecting system using NaI(Tl) is very important. The variation of environment temperature, the change of counting rate and long time continuous working of detector will cause un-negligible effect on the measurement. Three approaches were used. They are: 1) temperature control (It makes the effect of the variation of environment temperature on the measurement negligible.); 2) spectrum stabilizing (It adjust the peak position of the spectrum when the counting rate changes.); and 3) auto-checking and adjusting (It adjusts the drift of the NaI(Tl) detecting system when it works continuously)

  15. Standardization of 201Tl and 55Fe radionuclides in a 4 (PC)-NaI(Tl) coincidence system

    International Nuclear Information System (INIS)

    Pires, Carlos Augusto

    2008-01-01

    In the present work the procedure for the standardization of radionuclides using the 4π(PC)-NaI(Tl) coincidence system was developed. The radionuclides selected were 201 Tl, used in nuclear medicine, and 55 Fe primary standard source, used for x-ray spectrometers calibration. The 4π(PC)-NaI(Tl) is composed of a 4 proportional counter operated at 0.1MPa coupled to two NaI(Tl) crystals. The 201 Tl decays by electron capture process followed by a prompt gamma-ray. The disintegration rate was determined by extrapolation technique using two methods: electronic discrimination and external absorbers. The radioactive sources were prepared in a 20 μg cm -2 thick Collodion film. The conventional electronic system was used. The observed events were registered by the TAC method. The 55 Fe decays by electron capture process to the ground state of 55 Mn, emitting x rays with around 6 keV. The standardization was obtained by the tracing method. This technique was applied using two radionuclides, which decay by electron capture process followed by a prompt gamma-ray, namely 51 Cr and 54 Mn, as tracers. Measurements with 1 and 2 aluminum foils, each 150 g cm-2 thick were carried out. The activity was obtained by extrapolation for zero thickness Al foil. The uncertainties were treated by means of matrix covariance methodology and takes into account all correlations involved. (author)

  16. Genotypic variation in transpiration efficiency due to differences in photosynthetic capacity among sugarcane-related clones.

    Science.gov (United States)

    Li, Chunjia; Jackson, Phillip; Lu, Xin; Xu, Chaohua; Cai, Qing; Basnayake, Jayapathi; Lakshmanan, Prakash; Ghannoum, Oula; Fan, Yuanhong

    2017-04-01

    Sugarcane, derived from the hybridization of Saccharum officinarum×Saccharum spontaneum, is a vegetative crop in which the final yield is highly driven by culm biomass production. Cane yield under irrigated or rain-fed conditions could be improved by developing genotypes with leaves that have high intrinsic transpiration efficiency, TEi (CO2 assimilation/stomatal conductance), provided this is not offset by negative impacts from reduced conductance and growth rates. This study was conducted to partition genotypic variation in TEi among a sample of diverse clones from the Chinese collection of sugarcane-related germplasm into that due to variation in stomatal conductance versus that due to variation in photosynthetic capacity. A secondary goal was to define protocols for optimized larger-scale screening of germplasm collections. Genotypic variation in TEi was attributed to significant variation in both stomatal and photosynthetic components. A number of genotypes were found to possess high TEi as a result of high photosynthetic capacity. This trait combination is expected to be of significant breeding value. It was determined that a small number of observations (16) is sufficient for efficiently screening TEi in larger populations of sugarcane genotypes The research methodology and results reported are encouraging in supporting a larger-scale screening and introgression of high transpiration efficiency in sugarcane breeding. However, further research is required to quantify narrow sense heritability as well as the leaf-to-field translational potential of genotypic variation in transpiration efficiency-related traits observed in this study. © The Author 2017. Published by Oxford University Press on behalf of the Society for Experimental Biology.

  17. Magnetism and superconductivity of some Tl-Cu oxides

    Science.gov (United States)

    Datta, Timir

    1991-01-01

    Many copper oxide based Thallium compounds are now known. In comparison to the Bi-compounds, the Tl-system shows a richer diversity; i.e., High Temperature Superconductors (HTSC) can be obtained with either one or two Tl-0 layers (m = 1,2); also, the triple-digit phases are easier to synthesize. The value of d, oxygen stoichiometry, is critical to achieving superconductivity. The Tl system is robust to oxygen loss; Tl may be lost or incorporated by diffusion. A diffusion coefficient equal to 10 ms at 900 C was determined. Both ortho-rhombic and tetragonal structures are found, but HTSC behavior is indifferent to the crystal symmetry. This system has the highest T(sub c) confirmed. T(sub c) generally increases with p, the number of CuO layers, but tends to saturate at p = 3. Zero resistance was observed at temperatures as great as 125 K. Most of these HTSC's are hole type, but the Ce-doped specimens may be electronic. The magnetic aspects were studied; because in addition to defining the perfectly diamagnetic ground state as in conventional superconductors, magnetism of the copper oxides show a surprising variety. This is true of both the normal and the superconducting states. Also, due to the large phonon contribution to the specific heat at the high T(sub c) jump, electronic density of states, D(Ef), and coherence length are uncertain, and thus, are estimated from the magnetic results. Results from the Tl-system CuO, LaBaCuO,120 and the Bi-CuO compounds are discussed. The emphasis is on the role of magnetism in the Tl-CuO HTSC, but technological aspects are also pointed out.

  18. Expanding the Teaching Commons: Making the Case for a New Perspective on SoTL

    Directory of Open Access Journals (Sweden)

    Kim A. Case, PhD

    2013-08-01

    Full Text Available As a reflection on O’Meara, Terosky, and Neumann’s (2011 work on scholarship of teaching and learning (SoTL faculty development, this essay describes the benefits of SoTL to individual faculty and university goals. In support and expansion of arguments advanced by O’Meara et al., this work calls for the use of SoTL faculty development to promote the shared teaching commons, active recruitment of new SoTL scholars, institutionalization of SoTL values, and integration of SoTL initiatives in both teaching centers and research-focused development offices.

  19. The model of recombination process in TlBr

    International Nuclear Information System (INIS)

    Grigorjeva, L.; Millers, D.

    2002-01-01

    The time-resolved luminescence was used as a tool in the study of recombination process in several undoped TlBr crystals. The spectra and decay kinetics observed under electron beam excitation were investigated. Observation of several luminescence bands with different decay rates shows that more than one recombination center is involved and the recombination process is quite complicated. The band at ∼2.5 eV is dominant under 10 ns excitation pulse (electron beam or nitrogen laser pulses). The results of short-lived absorption and luminescence are used for analysis of possible mechanisms of recombination processes in TlBr

  20. Portable in situ NaI(Tl) γ spectroscopy system

    International Nuclear Information System (INIS)

    Wang Bairong; Dong Binjiang; Zeng Liping; Shen Tingyun

    2000-01-01

    The author describes a portable in situ NaI(Tl) γ spectroscopy system, which consists of a NaI (Tl) scintillation detector, an integrative spectroscopy card, a notebook computer and spectroscopy software. The spectrometer addresses applications in environmental or nuclear accident in situ γ spectroscopy measurements, and gives valid quantitative results of radionuclide concentrations per unit volume (Bq/kg) or unit area (Bq/cm 2 ) in the soil and absorbed dose rate in air at 1 m above ground (Gy/h)

  1. Anisotropic superconducting state parameters of Tl-2212 superconductors

    International Nuclear Information System (INIS)

    Khaskalam, Amit K.; Singh, R.K.; Varshney, Dinesh

    2001-01-01

    We have estimated the superconducting state parameters and their anisotropy in thallium based superconductors (Tl-2212), in the frame work of Fermi liquid approach. Determination of the effective mass of the charge carriers from the Fermi velocity and estimated anisotropic superconducting state parameters, particularly, the magnetic penetration depth along and perpendicular to the conducting plane. The coherence length along and perpendicular to the ab plane is evaluated and appears to be higher. The temperature dependence of penetration depth, their anisotropy and Ginsburg Landau parameter for optimised doped Tl based cuprates shows the power law. The technique permits a consistency with the reported data. (author)

  2. Coronary spasm: 201Tl scintiscanning following pharmacological provocation

    International Nuclear Information System (INIS)

    Montz, R.; Mathey, D.; Bleifeld, W.; Hamburg Univ.

    1981-01-01

    According to the authors' experience so far, 201 Tl myocardial scintiscanning is a sufficiently sensitive non-invasive method for detection of coronary vasospasm provoked by ergotamine administration. Mild incomplete and asymptotic forms of coronary vasospasm were detected by scintiscanning. Indications for myocardial scintiscanning of ergotamine-provoked vasospasm are: Cases of angina pectoris at rest in which electrocardiograms during spasm are not available; elleviated symptoms after nitroglycerine administration; exercise electrocardiograms without any sign of ischaemia; negative results of exercise 201 Tl myocardial scintiscanning. (orig.) [de

  3. Thermoluminescence (TL) in the identification of irradiated food

    International Nuclear Information System (INIS)

    Luthra, J.M.

    1992-01-01

    Due to progressive expansion of commercial food irradiation in recent years, the interest in detecting whether a food has been irradiated or not is growing fast and research in several methods for identification of various irradiated food stuffs is the order of the day. TL has emerged as one of the most promising tool for distinguishing between irradiated and unirradiated food. Advantages of TL method over other physical methods, its application to various foods, limitation and present state of art are discussed.(author). 9 refs., 3 tabs

  4. Automation of TL brick dating by ADAM-1

    International Nuclear Information System (INIS)

    Cechak, T.; Gerndt, J.; Hirsl, P.; Jirousek, P.; Kubelik, M.; Musilek, L.; Kanaval, J.

    2000-01-01

    Thermoluminescence has become an established dating method for ceramics and more recently for bricks. Based on the experiences of the work carried out since the late 1970's at the Rathgen-Forschungslabor in Berlin on the dating of bricks from historic architecture, and after evaluating all commercially available and some individually built automated and semi-automated TL-readers, a specially adapted machine for the fine grain dating of bricks was constructed in an interdisciplinary research project, undertaken by a team recruited from three faculties of the Czech Technical University in Prague. The result is the automated TL-reader ADAM-1 (Automated Dating Apparatus for Monuments) for the dating of historic architecture. Both the specific adaptation of the technique and the necessary optimal automation have influenced the design of this TL-reader. The principle advantage of brick as opposed to ceramic TL-dating emerges from the possibility of being able to obtain both a large number of samples and an above average quantity of datable material from each sample. This, together with the specific physical and chemical conditions in a brick wall, allowed a rethinking of the traditional error calculation and thus lower error margins as those obtained when dating ceramic shards. The TL-reader must therefore be able to measure and evaluate automatically numerous samples. The annular sample holder of ADAM-1 has 60 sample positions, which allow the irradiation and evaluation of samples taken from two locations. The thirty samples from one sampling point are divided into subgroups, which are processed in various ways. Three samples serve for a rough estimate of the TL sensitivity of the brick material. Nine samples are used for the measurement of 'natural TL' of the material. A further nine samples are used for testing the sensitivity of the material to beta radiation. The last nine samples serve for the testing of the sensitivity to alpha radiation. To determine the

  5. Energy efficiency analysis: biomass-to-wheel efficiency related with biofuels production, fuel distribution, and powertrain systems.

    Directory of Open Access Journals (Sweden)

    Wei-Dong Huang

    Full Text Available BACKGROUND: Energy efficiency analysis for different biomass-utilization scenarios would help make more informed decisions for developing future biomass-based transportation systems. Diverse biofuels produced from biomass include cellulosic ethanol, butanol, fatty acid ethyl esters, methane, hydrogen, methanol, dimethyether, Fischer-Tropsch diesel, and bioelectricity; the respective powertrain systems include internal combustion engine (ICE vehicles, hybrid electric vehicles based on gasoline or diesel ICEs, hydrogen fuel cell vehicles, sugar fuel cell vehicles (SFCV, and battery electric vehicles (BEV. METHODOLOGY/PRINCIPAL FINDINGS: We conducted a simple, straightforward, and transparent biomass-to-wheel (BTW analysis including three separate conversion elements--biomass-to-fuel conversion, fuel transport and distribution, and respective powertrain systems. BTW efficiency is a ratio of the kinetic energy of an automobile's wheels to the chemical energy of delivered biomass just before entering biorefineries. Up to 13 scenarios were analyzed and compared to a base line case--corn ethanol/ICE. This analysis suggests that BEV, whose electricity is generated from stationary fuel cells, and SFCV, based on a hydrogen fuel cell vehicle with an on-board sugar-to-hydrogen bioreformer, would have the highest BTW efficiencies, nearly four times that of ethanol-ICE. SIGNIFICANCE: In the long term, a small fraction of the annual US biomass (e.g., 7.1%, or 700 million tons of biomass would be sufficient to meet 100% of light-duty passenger vehicle fuel needs (i.e., 150 billion gallons of gasoline/ethanol per year, through up to four-fold enhanced BTW efficiencies by using SFCV or BEV. SFCV would have several advantages over BEV: much higher energy storage densities, faster refilling rates, better safety, and less environmental burdens.

  6. Energy Efficiency Analysis: Biomass-to-Wheel Efficiency Related with Biofuels Production, Fuel Distribution, and Powertrain Systems

    Science.gov (United States)

    Huang, Wei-Dong; Zhang, Y-H Percival

    2011-01-01

    Background Energy efficiency analysis for different biomass-utilization scenarios would help make more informed decisions for developing future biomass-based transportation systems. Diverse biofuels produced from biomass include cellulosic ethanol, butanol, fatty acid ethyl esters, methane, hydrogen, methanol, dimethyether, Fischer-Tropsch diesel, and bioelectricity; the respective powertrain systems include internal combustion engine (ICE) vehicles, hybrid electric vehicles based on gasoline or diesel ICEs, hydrogen fuel cell vehicles, sugar fuel cell vehicles (SFCV), and battery electric vehicles (BEV). Methodology/Principal Findings We conducted a simple, straightforward, and transparent biomass-to-wheel (BTW) analysis including three separate conversion elements -- biomass-to-fuel conversion, fuel transport and distribution, and respective powertrain systems. BTW efficiency is a ratio of the kinetic energy of an automobile's wheels to the chemical energy of delivered biomass just before entering biorefineries. Up to 13 scenarios were analyzed and compared to a base line case – corn ethanol/ICE. This analysis suggests that BEV, whose electricity is generated from stationary fuel cells, and SFCV, based on a hydrogen fuel cell vehicle with an on-board sugar-to-hydrogen bioreformer, would have the highest BTW efficiencies, nearly four times that of ethanol-ICE. Significance In the long term, a small fraction of the annual US biomass (e.g., 7.1%, or 700 million tons of biomass) would be sufficient to meet 100% of light-duty passenger vehicle fuel needs (i.e., 150 billion gallons of gasoline/ethanol per year), through up to four-fold enhanced BTW efficiencies by using SFCV or BEV. SFCV would have several advantages over BEV: much higher energy storage densities, faster refilling rates, better safety, and less environmental burdens. PMID:21765941

  7. Energy efficiency analysis: biomass-to-wheel efficiency related with biofuels production, fuel distribution, and powertrain systems.

    Science.gov (United States)

    Huang, Wei-Dong; Zhang, Y-H Percival

    2011-01-01

    Energy efficiency analysis for different biomass-utilization scenarios would help make more informed decisions for developing future biomass-based transportation systems. Diverse biofuels produced from biomass include cellulosic ethanol, butanol, fatty acid ethyl esters, methane, hydrogen, methanol, dimethyether, Fischer-Tropsch diesel, and bioelectricity; the respective powertrain systems include internal combustion engine (ICE) vehicles, hybrid electric vehicles based on gasoline or diesel ICEs, hydrogen fuel cell vehicles, sugar fuel cell vehicles (SFCV), and battery electric vehicles (BEV). We conducted a simple, straightforward, and transparent biomass-to-wheel (BTW) analysis including three separate conversion elements--biomass-to-fuel conversion, fuel transport and distribution, and respective powertrain systems. BTW efficiency is a ratio of the kinetic energy of an automobile's wheels to the chemical energy of delivered biomass just before entering biorefineries. Up to 13 scenarios were analyzed and compared to a base line case--corn ethanol/ICE. This analysis suggests that BEV, whose electricity is generated from stationary fuel cells, and SFCV, based on a hydrogen fuel cell vehicle with an on-board sugar-to-hydrogen bioreformer, would have the highest BTW efficiencies, nearly four times that of ethanol-ICE. In the long term, a small fraction of the annual US biomass (e.g., 7.1%, or 700 million tons of biomass) would be sufficient to meet 100% of light-duty passenger vehicle fuel needs (i.e., 150 billion gallons of gasoline/ethanol per year), through up to four-fold enhanced BTW efficiencies by using SFCV or BEV. SFCV would have several advantages over BEV: much higher energy storage densities, faster refilling rates, better safety, and less environmental burdens.

  8. Thermoluminescent relative efficiencies of TLD-100 for nitrogen ions respect of gamma radiation

    International Nuclear Information System (INIS)

    Concha S, K.; Avila, O.; Gamboa de Buen, I.; Rodriguez V, M.; Buenfil, A.E.; Ruiz T, C.; Brandan, M.E.

    2004-01-01

    The purpose of this work is to measure the thermoluminescent relative efficiency of those TLD-100 dosemeters irradiated with nitrogen ions with respect to the gamma radiation of 60 Co, in function of the linear energy transfer (LET). Two energy of such nitrogen ions were selected that has the same value from LET when impacting in the dosemeters but with E 1 energy (4.8 MeV) and E 2 (9.95 MeV) smaller and greater respectively that the energy of the Bragg peak. (Author)

  9. Relative efficiency and productivity: a preliminary exploration of public hospitals in Beijing, China.

    Science.gov (United States)

    Li, Hao; Dong, Siping; Liu, Tingfang

    2014-04-06

    Third-grade hospitals in Beijing have been rapidly developing in capacity and scale for many years. These hospitals receive a large number of patients, and ensuring their efficient operation is crucial in meeting people's healthcare needs. In this context, a study of their relative efficiency and productivity would be helpful to identify the driving factors and further improve their performance. After a review of literature, the current numbers of open beds and employees were selected as input variables. The number of outpatient and emergency visits and the number of discharged patients were selected as output variables. A total of 12 third-grade Class A general public hospitals in Beijing were selected for a preliminary study. The panel data from 2006-2009 were collected by the National Institute of Hospital Administration, Ministry of Health of P.R. China. Descriptive analysis and data envelopment analysis were used to analyze the data using Stata 10.0 and DEAP(V2.1) software. In the 2006-2009 period, descriptive results show that sample hospitals continuously expanded their capacity and scale, with growth rate of total revenue being the highest among all variables. The DEA results show that the average annual growth rate of productivity was 26.7%, and the rates were 47.3%, 21.3% and 13.8% respectively for two consecutive years. The average annual growth rate of technological change was 28.3%, and the rates were 49.4%, 21.5% and 16.4% respectively for two consecutive years. The average annual growth rate of technical efficiency change was -1.3%, and the rates were -1.4%, -0.02% and -2.2% respectively for two consecutive years. The sample hospitals in Beijing experienced substantial productivity growth, but annual growth rates were declining. Substantial technological change was the main contributor to the growth. Although some hospitals exhibited improvements in technical efficiency, there was a slight decline in general. To improve overall efficiency and

  10. Relative efficiency and productivity: a preliminary exploration of public hospitals in Beijing, China

    Science.gov (United States)

    2014-01-01

    Background Third-grade hospitals in Beijing have been rapidly developing in capacity and scale for many years. These hospitals receive a large number of patients, and ensuring their efficient operation is crucial in meeting people’s healthcare needs. In this context, a study of their relative efficiency and productivity would be helpful to identify the driving factors and further improve their performance. Methods After a review of literature, the current numbers of open beds and employees were selected as input variables. The number of outpatient and emergency visits and the number of discharged patients were selected as output variables. A total of 12 third-grade Class A general public hospitals in Beijing were selected for a preliminary study. The panel data from 2006–2009 were collected by the National Institute of Hospital Administration, Ministry of Health of P.R. China. Descriptive analysis and data envelopment analysis were used to analyze the data using Stata 10.0 and DEAP(V2.1) software. Results In the 2006–2009 period, descriptive results show that sample hospitals continuously expanded their capacity and scale, with growth rate of total revenue being the highest among all variables. The DEA results show that the average annual growth rate of productivity was 26.7%, and the rates were 47.3%, 21.3% and 13.8% respectively for two consecutive years. The average annual growth rate of technological change was 28.3%, and the rates were 49.4%, 21.5% and 16.4% respectively for two consecutive years. The average annual growth rate of technical efficiency change was -1.3%, and the rates were -1.4%, -0.02% and -2.2% respectively for two consecutive years. Conclusions The sample hospitals in Beijing experienced substantial productivity growth, but annual growth rates were declining. Substantial technological change was the main contributor to the growth. Although some hospitals exhibited improvements in technical efficiency, there was a slight decline in

  11. Calculated energy dependence of CaSO4:Dy TL phosphor and phosphor embedded Teflon for X and gamma rays

    International Nuclear Information System (INIS)

    Chang, J.-K.; Nam, Y.-M.; Kim, J.-L.; Chang, S.-Y.; Kim, B.-H.

    2001-01-01

    The energy dependence of a CaSO 4 :Dy TL phosphor for 21 monoenergetic photons of energy ranging from 0.01 to 3 MeV was calculated by using MCNP4A code. The calculation results show good agreement with those of other authors within ± 5% relative error. Calculations and experiments are also performed to determine the energy dependence of CaSO 4 : Dy phosphor with Dy concentrations from 0.01 to 1.5 mol %, and with the compositions of TL-Teflon from 10 to 90 wt %. The calculated energy responses show good agreement with the experiment results within ± 20% relative error except for a concentration lower than 0.1 mol % Dy and the low energy regions of M30 (Eave.=20 keV) and M60 (Eave.=34 keV). For the TL-Teflon mixture, the energy dependence shows an decreasing trend with the increase of Teflon concentration in MCNP calculation but shows no dependence for TL-Teflon mixture proportions in experiment. These differences are due to the non-homogeneous distribution of Dy concentration and the effect of large grain size in the phosphors. The energy dependence of the 30 wt/o CaSO 4 (0.1 mol%;Dy) and 70 wt/o Teflon that is placed behind the filters of plastic, aluminum, copper, tin and lead with a thickness from 0.1 to 2 mm were calculated, respectively

  12. Vortex states of Tl2Ba2CuO6+δ studied via 205Tl NMR at 2 tesla

    International Nuclear Information System (INIS)

    Itoh, Yutaka; Michioka, Chishiro; Yoshimura, Kazuyoshi; Hayashi, Akihiko; Ueda, Yutaka

    2005-01-01

    We report a 205 Tl NMR study of vortex states in an aligned polycrystalline sample of an overdoped high-T c superconductor, Tl 2 Ba 2 CuO 6+δ (Tc - 85 K), at a magnetic field of 2 T along the c axis. We observed an imperfect vortex lattice, so-called Bragg glass, at T=5 K, the coexistence of vortex solid and vortex liquid between 10 and 60 K, and vortex melting between 65 and 85 K. No evidence for local antiferromagnetic ordering at vortex cores was found for our sample. (author)

  13. Theoretical analysis and experimental evaluation of a CsI(Tl) based electronic portal imaging system

    International Nuclear Information System (INIS)

    Sawant, Amit; Zeman, Herbert; Samant, Sanjiv; Lovhoiden, Gunnar; Weinberg, Brent; DiBianca, Frank

    2002-01-01

    This article discusses the design and analysis of a portal imaging system based on a thick transparent scintillator. A theoretical analysis using Monte Carlo simulation was performed to calculate the x-ray quantum detection efficiency (QDE), signal to noise ratio (SNR) and the zero frequency detective quantum efficiency [DQE(0)] of the system. A prototype electronic portal imaging device (EPID) was built, using a 12.7 mm thick, 20.32 cm diameter, CsI(Tl) scintillator, coupled to a liquid nitrogen cooled CCD TV camera. The system geometry of the prototype EPID was optimized to achieve high spatial resolution. The experimental evaluation of the prototype EPID involved the determination of contrast resolution, depth of focus, light scatter and mirror glare. Images of humanoid and contrast detail phantoms were acquired using the prototype EPID and were compared with those obtained using conventional and high contrast portal film and a commercial EPID. A theoretical analysis was also carried out for a proposed full field of view system using a large area, thinned CCD camera and a 12.7 mm thick CsI(Tl) crystal. Results indicate that this proposed design could achieve DQE(0) levels up to 11%, due to its order of magnitude higher QDE compared to phosphor screen-metal plate based EPID designs, as well as significantly higher light collection compared to conventional TV camera based systems

  14. Performance of novel materials for radiation detection: Tl3AsSe3, TlGaSe2, and Tl4HgI6

    International Nuclear Information System (INIS)

    Kahler, D.; Singh, N.B.; Knuteson, D.J.; Wagner, B.; Berghmans, A.; McLaughlin, S.; King, M.; Schwartz, K.; Suhre, D.; Gotlieb, M.

    2011-01-01

    In this paper we report on the electrical characteristics of three novel ternary compounds, Tl 3 AsSe 3 (TAS), TlGaSe 2 (TGS), and Tl 4 HgI 6 (THI), pertaining to their use as radiation detectors. The details for growth and material characterization are not presented. A semiconductor based gamma ray detector requires a material with high Z, high density, high resistivity, appropriate bandgap (1.5-2 eV), low energy/electron-hole pair, and a high μτ product. CZT is currently the best semiconductor material for room temperature gamma ray spectroscopy; however, it is extremely difficult to produce large volumes of detector grade material, making it expensive and in limited supply. DNDO/DHS began searching for other materials that might perform as well as CZT but be easier to grow and in the end lower the cost. For this purpose, we investigated the above three materials as possible replacements for CZT as gamma ray detectors. The bulk resistivity, I-V curves, X-ray response, and gamma ray response measurements for doped and undoped crystals are presented and discussed. TAS shows good X-ray and gamma ray response, but has poor resistivity, which results in large dark current and poor spectral response. TGS has good resistivity, but shows poor X-ray and gamma ray response. THI has excellent resistivity, shows some X-ray and gamma ray response, and has great potential as a gamma ray detector.

  15. Numerical multistep methods for the efficient solution of quantum mechanics and related problems

    International Nuclear Information System (INIS)

    Anastassi, Z.A.; Simos, T.E.

    2009-01-01

    In this paper we present the recent development in the numerical integration of the Schroedinger equation and related systems of ordinary differential equations with oscillatory solutions, such as the N-body problem. We examine several types of multistep methods (explicit, implicit, predictor-corrector, hybrid) and several properties (P-stability, trigonometric fitting of various orders, phase fitting, high phase-lag order, algebraic order). We analyze the local truncation error and the stability of the methods. The error for the Schroedinger equation is also presented, which reveals the relation of the error to the energy. The efficiency of the methods is evaluated through the integration of five problems. Figures are presented and analyzed and some general conclusions are made. Code written in Maple is given for the development of all methods analyzed in this paper. Also the subroutines written in Matlab, that concern the integration of the methods, are presented.

  16. Input-output relation and energy efficiency in the neuron with different spike threshold dynamics.

    Science.gov (United States)

    Yi, Guo-Sheng; Wang, Jiang; Tsang, Kai-Ming; Wei, Xi-Le; Deng, Bin

    2015-01-01

    Neuron encodes and transmits information through generating sequences of output spikes, which is a high energy-consuming process. The spike is initiated when membrane depolarization reaches a threshold voltage. In many neurons, threshold is dynamic and depends on the rate of membrane depolarization (dV/dt) preceding a spike. Identifying the metabolic energy involved in neural coding and their relationship to threshold dynamic is critical to understanding neuronal function and evolution. Here, we use a modified Morris-Lecar model to investigate neuronal input-output property and energy efficiency associated with different spike threshold dynamics. We find that the neurons with dynamic threshold sensitive to dV/dt generate discontinuous frequency-current curve and type II phase response curve (PRC) through Hopf bifurcation, and weak noise could prohibit spiking when bifurcation just occurs. The threshold that is insensitive to dV/dt, instead, results in a continuous frequency-current curve, a type I PRC and a saddle-node on invariant circle bifurcation, and simultaneously weak noise cannot inhibit spiking. It is also shown that the bifurcation, frequency-current curve and PRC type associated with different threshold dynamics arise from the distinct subthreshold interactions of membrane currents. Further, we observe that the energy consumption of the neuron is related to its firing characteristics. The depolarization of spike threshold improves neuronal energy efficiency by reducing the overlap of Na(+) and K(+) currents during an action potential. The high energy efficiency is achieved at more depolarized spike threshold and high stimulus current. These results provide a fundamental biophysical connection that links spike threshold dynamics, input-output relation, energetics and spike initiation, which could contribute to uncover neural encoding mechanism.

  17. Development of efficient time-evolution method based on three-term recurrence relation

    International Nuclear Information System (INIS)

    Akama, Tomoko; Kobayashi, Osamu; Nanbu, Shinkoh

    2015-01-01

    The advantage of the real-time (RT) propagation method is a direct solution of the time-dependent Schrödinger equation which describes frequency properties as well as all dynamics of a molecular system composed of electrons and nuclei in quantum physics and chemistry. Its applications have been limited by computational feasibility, as the evaluation of the time-evolution operator is computationally demanding. In this article, a new efficient time-evolution method based on the three-term recurrence relation (3TRR) was proposed to reduce the time-consuming numerical procedure. The basic formula of this approach was derived by introducing a transformation of the operator using the arcsine function. Since this operator transformation causes transformation of time, we derived the relation between original and transformed time. The formula was adapted to assess the performance of the RT time-dependent Hartree-Fock (RT-TDHF) method and the time-dependent density functional theory. Compared to the commonly used fourth-order Runge-Kutta method, our new approach decreased computational time of the RT-TDHF calculation by about factor of four, showing the 3TRR formula to be an efficient time-evolution method for reducing computational cost

  18. Superdeformation studies in the odd-odd nucleus {sup 192}Tl

    Energy Technology Data Exchange (ETDEWEB)

    Fischer, S.; Carpenter, M.P.; Janssens, R.V.F. [and others

    1995-08-01

    The study of yrast and near-yrast structures of odd-odd nuclei to high spins is somewhat limited due to the complexity of the spectra resulting from the many proton-neutron couplings near the Fermi surface. In superdeformed nuclei, the number of available protons and neutrons near the Fermi surface is somewhat limited due to the presence of large-shell gaps which stabilize the nuclear shape. A relatively small number of available neutron and proton configurations can lead to fragmentation of the SD intensity into a number of different bands. Two good examples of this phenomenon were found in {sup 192}Tl and {sup 194}Tl where the presence of six superdeformed bands were reported in both nuclei. We reexamined {sup 192}Tl at Gammasphere using the {sup 160}Gd({sup 37}Cl,5n) reaction at 178 MeV to populate states in the superdeformed well of this nucleus. While our previous study on {sup 192}Tl at ATLAS was very successful, a number of questions remained which formed the basis of our objectives in this experiment: obtain better {gamma}-ray energies for the known transitions and identify higher spin members in each band; determine how the bands feed the known yrast states in {sup 192}Tl as well as determine the complete spectrum in coincidence with the SD bands; look for M1 transitions connecting proposed signature partners; and attempt to identify other excitations in the superdeformed well. Analysis is underway and four of the six bands were confirmed. The reasons that two of the reported bands were not observed in this latest work is still under investigation. As of this time, no other superdeformed bands were identified in the data. Two of the confirmed SD bands have a constant moment of inertia and show indications of cross-talk between each other. This observation is not unexpected since the calculated M1 rates for the proposed configuration of the band, {pi}{sub 13/2} x {upsilon}j{sub 15/2}, indicate that M1 transitions linking the two SD bands should be observed.

  19. Development of a TL personal dosimeter identifiable PA exposure, and comparison with commercial TL dosimeters

    International Nuclear Information System (INIS)

    Kwon, J.W.; Kim, H.K.; Lee, J.K.; Kim, J.L.

    2004-01-01

    A single-dosimeter worn on the anterior surface of the body of a worker was found to significantly underestimate the effective dose to the worker when the radiation comes from the back. Several researchers suggested that this sort of underestimation can be corrected to a certain extent by using an extra dosimeter on the back. However, use of multiple dosimeters also has disadvantages such as complication in control or incurrence of extra cost. Instead of the common multi-dosimeter approach, in this study, a single dosimeter introducing asymmetric filters which enabled to identify PA exposure was designed, and its dose evaluation algorithm for AP-PA mixed radiation fields was established. A prototype TL personal dosimeter was designed and constructed. The Monte Carlo simulations were utilized in the design process and verified by experiments. The dosimeter and algorithm were applicable to photon radiation having an effective energy beyond 100 keV in AP-PA mixed radiation fields. A simplified performance test based on ANSI N13.11 showed satisfactory results. Considering that the requirements of the International Electrotechnical Commission (IEC) and the American National Standards Institute (ANSI) with regard to the dosimeter on angular dependency is reinforced, the dosimeter and the dose evaluation algorithm developed in this study provides a useful approach in practical personal dosimetry against inhomogeneous high energy radiation fields. (author)

  20. Real-time in-situ monitoring of the topotactic transformation of TlCu{sub 3}Se{sub 2} into TlCu{sub 2}Se{sub 2}

    Energy Technology Data Exchange (ETDEWEB)

    Ångström, J.; Sahlberg, M.; Berger, R.

    2015-07-15

    Highlights: • Topotactic transition from TlCu{sub 3}Se{sub 2} to TlCu{sub 2}Se{sub 2} followed in situ. • Synchrotron radiation X-ray powder diffraction enabled short scans. • Relative abundance of phases refined from powder data. • Opens up for studying similar systems in the same manner. - Abstract: The solid state transformation of monoclinic TlCu{sub 3}Se{sub 2} into tetragonal TlCu{sub 2}Se{sub 2} by oxidative copper leaching in concentrated ammonia solution has been studied in situ by the use of synchrotron radiation. The diffraction patterns of parent and daughter phase are both sharp, indicating a strong topotactic relationship between them that effectuates a rapid change by “chimie douce” performed at +19 °C. The transformation rate is strongly connected to the access of oxygen from the surrounding air. The transformation was followed in a real-time mode, being almost complete after 2.5 h with 1 h incubation due to low oxygen content, as shown from refining the diffraction patterns by Rietveld profile technique.

  1. X-ray dosimetry of TlGaSe2 single crystals

    International Nuclear Information System (INIS)

    Kerimova, E.M.; Mustafaeva, S.N.; Mamedbeili, S.D.; Jabarov, J.N.; Iskenderova, P.M.; Kazimov, S.B.

    2002-01-01

    TlGaSe 2 compound belongs to group of layered semiconductors of A 3 B 3 C 2 6 -type. Photoelectric and optical properties of TlGaSe 2 single crystals were investigated in detail. Influence of gamma-, electron and neutron radiation on photoelectric properties of TlGaSe 2 single crystals is investigated too. The present work deals with experimental results relative to X-ray dosimetric characteristics of TlGaSe 2 crystals at 300 K. X-ray conductivity and X-ray dosimetric characteristic measurements are carried out in low load resistance regime. The source of X-ray radiation is the installation of X-ray diffraction analysis (URS-55a) with the BCV-2(Cu). Intensity of X-ray radiation (E) is regulated by measurement with current variation in tube at each given value of X-ray radiation dose E (R/min) are measured by crystal dosimeter DRGZ-02. X-ray conductivity coefficients K σ characterising X-ray sensitivity of investigated crystals are determined as the relative change of conductivity under X-ray radiation a per dose. There have been determined values of characteristic coefficients of TlGaSe 2 single crystal X-ray conductivity at different values of accelerating voltage (V a ) on the tube and corresponding doses of X-ray radiation. Analysis of obtained data showed that X-ray conductivity coefficients K σ in studied crystals are regularly decreased (from 0.276 to 0.033) as with the rise of dose (E=0.75-78.0 R/min) as with the increase of values of V a on X-ray tube (V a =254-50 keV). One of the possible reasons of observed regularities is that X-ray conductivity in investigated crystals, especially at comparatively low V a is due predominantly to radiation of thin layer of crystal. In this case with the rise of radiation intensity there have been started to prevail the mechanism of surface quadratic recombination which leads to observed decrease of X-ray conductivity. With the rise of accelerating potential 'effective hardness' is increased, as a result of which there

  2. Giant Rashba spin splitting in Bi2Se3: Tl

    KAUST Repository

    Singh, Nirpendra; Saeed, Yasir; Schwingenschlö gl, Udo

    2014-01-01

    First-principles calculations are employed to demonstrate a giant Rashba spin splitting in Bi2Se3:Tl. Biaxial tensile and compressive strain is used to tune the splitting by modifying the potential gradient. The band gap is found to increase under

  3. Preparation of biaxially oriented TlCu-1234 thin films

    CERN Document Server

    Khan, N A; Tateai, F; Kojima, T; Ishida, K; Terada, N; Ihara, H

    1999-01-01

    The single phase of TlCu-1234 superconductor thin films is prepared for the first time by the amorphous phase epitaxy (APE) method, which is thallium treatment of sputtered amorphous phase at 900 degrees C for 1 h. The amorphous $9 phase is prepared by sputtering from the stoichiometric target composition CuBa/sub 2/Ca/sub 3/Cu/sub 4/O/sub 12-y/. The films on the SrTiO/sub 3/ substrate are aligned biaxially after the thallium treatment. Highly reproducible $9 TlCu-1234 films are prepared by this method. The XRD reflected a predominant single phase with the c-axis lattice constant of 18.74 AA. This lattice constant value is in between that of Cu-1234 (17.99 AA) and Tl-1234 (19.11 AA) . The $9 pole figure measurements of (103) reflection of the films showed a-axis-oriented crystals with Delta phi =0.8 degrees . The composition of the films after energy dispersive X-ray (EDX) measurements is Tl/sub 0.8/Cu/sub 0.2/Ba/sub $9 2/Ca/sub 3/Cu/sub 4/O /sub 12-y/. From the resistivity measurements, the T/sub c/ is 113 K...

  4. Reader's Response: What Is a SoTL?

    Science.gov (United States)

    Griebenow, Kai

    2010-01-01

    In this response to, "SoTL Commons Conference: A Spirit of Inquiry" (Margaret Davis, Kera Watkins, and Deborah Allen, "International Journal for the Scholarship of Teaching and Learning,"v3 n2 Jul 2009), Griebenow adds his personal impressions as an "SOTL newbie." He states that many scientists have an idea of…

  5. TL, EPR and optical absorption in natural grossular crystal

    Energy Technology Data Exchange (ETDEWEB)

    Yauri, J.M. [Institute of Physics, University of Sao Paulo, Rua do Matao, Travessa R, 187, CEP 05508-900, Sao Paulo (Brazil); Department of Physics, University of San Agustin, Av. Independencia S/N, Arequipa (Peru); Cano, N.F. [Institute of Physics, University of Sao Paulo, Rua do Matao, Travessa R, 187, CEP 05508-900, Sao Paulo (Brazil)], E-mail: nilocano@dfn.if.usp.br; Watanabe, S. [Institute of Physics, University of Sao Paulo, Rua do Matao, Travessa R, 187, CEP 05508-900, Sao Paulo (Brazil)

    2008-10-15

    Grossular is one of six members of silicate Garnet group. Two samples GI and GII have been investigated concerning their luminescence thermally stimulated (TL). EPR and optical absorption and the measurements were carried out to find out whether or not same point defects are responsible for all three properties. Although X-rays diffraction analysis has shown that both GI and GII have practically the same crystal structure of a standard grossular crystal, they presented different behavior in many aspects. The TL glow curve shape, TL response to radiation dose, the effect of annealing at high temperatures before irradiation, the dependence of UV bleaching parameters on peak temperature, all of them differ going from GI to GII. The EPR signals around g=2.0 as well as at g=4.3 and 6.0 have much larger intensity in GI than in GII. Very high temperature (>800 deg. C) annealing causes large increase in the bulk background absorption in GI, however, only very little in GII. In the cases of EPR and optical absorption, the difference in their behavior can be attributed to Fe{sup 3+} ions; however, in the TL case one cannot and the cause was not found as yet.

  6. Neutron Scattering from fcc Pr and Pr3Tl

    DEFF Research Database (Denmark)

    Birgeneau, R. J.; Als-Nielsen, Jens Aage; Bucher, E.

    1972-01-01

    Elastic-neutron-scattering measurements on the singlet-ground-state ferromagnets fcc Pr and Pr3 Tl are reported. Both exhibit magnetic phase transitions, possibly to a simple ferromagnetic state at 20 and 11.6 °K, respectively. The transitions appear to be of second order although that in fcc Pr...

  7. TL, EPR and optical absorption in natural grossular crystal

    International Nuclear Information System (INIS)

    Yauri, J.M.; Cano, N.F.; Watanabe, S.

    2008-01-01

    Grossular is one of six members of silicate Garnet group. Two samples GI and GII have been investigated concerning their luminescence thermally stimulated (TL). EPR and optical absorption and the measurements were carried out to find out whether or not same point defects are responsible for all three properties. Although X-rays diffraction analysis has shown that both GI and GII have practically the same crystal structure of a standard grossular crystal, they presented different behavior in many aspects. The TL glow curve shape, TL response to radiation dose, the effect of annealing at high temperatures before irradiation, the dependence of UV bleaching parameters on peak temperature, all of them differ going from GI to GII. The EPR signals around g=2.0 as well as at g=4.3 and 6.0 have much larger intensity in GI than in GII. Very high temperature (>800 deg. C) annealing causes large increase in the bulk background absorption in GI, however, only very little in GII. In the cases of EPR and optical absorption, the difference in their behavior can be attributed to Fe 3+ ions; however, in the TL case one cannot and the cause was not found as yet

  8. Thermal and x-ray studies on Tl2U(MoO4)3 and Tl4U(MoO4)4

    International Nuclear Information System (INIS)

    Dahale, N.D.; Keskar, Meera; Kulkarni, N.K.; Singh Mudher, K.D.

    2006-01-01

    In the quaternary Tl-U(IV)-Mo-O system, two new compounds namely Tl 2 U(MoO 4 ) 3 and Tl 4 U(MoO 4 ) 4 were prepared and characterized by powder X-ray diffraction and thermal methods. These compounds were prepared by solid state reactions of Tl 2 MoO 4 , UMoO 5 and MoO 3 in the required stoichiometric ratio at 500 deg C in evacuated sealed quartz ampoule. The XRD data of Tl 2 U(MoO 4 ) 3 and Tl 4 U(MoO 4 ) 4 were indexed on orthorhombic cell. TG curves of Tl 2 U(MoO 4 ) 3 and Tl 4 U(MoO 4 ) 4 did not show any weight change up to 700 deg C in an inert atmosphere. During heating in an inert atmosphere, Tl 2 U(MoO 4 ) 3 and Tl 4 U(MoO 4 ) 4 showed endothermic Dta peaks due to melting of the compounds at 519 and 565 deg C, respectively. (author)

  9. Quality control of the solution sup(201)TlCl obtained at IPEN-CNEN/SP by sup(201)Tl direct preparation

    International Nuclear Information System (INIS)

    Fernandes, L.; Silva, C.P.G. da

    1991-01-01

    The radiopharmaceutical sup(201) TlCl is used in Nuclear Medicine for myocardial visualization. The solution of sup(201)TlCl was prepared using sup(201)Tl obtained by irradiating a natural mercury target with protons. This radionuclide was subjected to different quality control processes to verify the purity required for its use in Medicine. Some of these controls concerned the determination of sup(200)Tl, sup(201)Tl and sup(202)Tl; the chemical identification of sup(201)Tl sup(+1); the hydrazine concentration, mercury contamination and the presence of phosphate. Furthermore, the biologic distribution in Wistar rats and tests for sterility pyrogens and for toxicity were carried out. It was verified that the solution obtained was in the form of tallous chloride. This radiopharmaceutical can give a good heart image in animals but due to the contamination of sup(201)Tl with sup(200)Tl and sup(202)Tl its use in human beings is not possible unless enriched sup(202)Hg is used as target of irradiation. (author)

  10. Investigating the origins of double photopeaks in CsI:Tl samples through activator mapping

    Science.gov (United States)

    Onken, Drew R.; Gridin, Sergii; Williams, Richard T.; Williams, Charles B.; Donati, George L.; Gayshan, Vadim; Vasyukov, Sergey; Gektin, Alex

    2018-06-01

    Careful examination of the origins of double photopeaks in CsI:Tl provides a foundation for exploring the relationship between activator homogeneity and photopeak resolution in scintillators. In rare cases, certain CsI:Tl crystals exhibit a second photopeak in the pulse-height spectrum. A combination of optical mapping and ICP-MS measurements reveals the presence of two distinct regions with differing Tl concentrations in these crystals. The oscillator strength of the 299 nm absorption A-band of Tl in CsI was measured to be 0.0526 ± 0.0008; this parameter can be used to quantify activator concentration from the optical absorption. Using published measurements of luminescence intensity versus Tl concentration, the distributions of Tl measured from optical absorption maps of the samples were reconstructed into photopeaks in good agreement with experiment. The distribution of Tl concentrations in these particular crystals allowed examining luminescence pulse shape as a function of Tl concentration.

  11. Supralinear response and efficiency of LiF:Mg,Ti to 0.7, 1.5 and 3 MeV protons

    International Nuclear Information System (INIS)

    Gamboa-deBuen, I.; Aviles, P.; Rodriguez-Villafuerte, M.; Buenfil, A.E.; Ruiz-Trejo, C.; Brandan, M.E.

    2001-01-01

    The thermoluminescent (TL) response, supralinearity function, and relative efficiency with respect to 60 Co γ-rays, of TLD-100 exposed to 0.7, 1.5 and 3 MeV protons have been measured. The TL response of the glow curve peaks using two different deconvolutions, separating in either 7 (3-9) or 9 peaks (3-10 and peaks 6a and 6b), was investigated. Results for the supralinearity function of peaks 5 and 7-9 and the relative response of peaks 5 and 7 are insensitive to the chosen deconvolution scheme. At all energies we observe that peak 5 is slightly supralinear and that supralinearity increases as a function of the peak temperature. The relative efficiencies, measured for the total TL signal (area under the glow curve) and peaks 5 and 7, decrease with the proton energy having values of 0.33, 0.46 and 0.70 (total TL signal), 0.22, 0.32 and 0.53 (peak 5) and 1.4, 2.6 and 3.6 (peak 7) at 0.7, 1.5 and 3 MeV, respectively. These data agree with the systematics reported in the literature. The measurements of the supralinearity function are compared with Monte Carlo track interaction model calculations. The analysis suggests that the model ion track effective radius and the saturation radius are independent of the incident ion energy

  12. Monitoring of garbage with a 5 x 5 NaI (Tl) detector; Monitoreo de basura con un detector de NaI (Tl) de 5 x 5

    Energy Technology Data Exchange (ETDEWEB)

    Cortes P, A.; Becerril V, A.; Angeles C, A

    1991-12-15

    So far in that is carried out the first reload of nuclear fuel in the LVC, the monitoring of garbage has been carried out using monitors trade mark Eberline model RM 14. The procedure consists in manually monitoring each object and to separate of the considered 'clean' garbage the objects considered as contaminated, which register greater or equal counts to 100 cpm. This way to process was adequate under normal operation conditions, but not in the operation rhythm that implies a bigger maintenance since the time required for monitoring from 5 to 10 kg. of garbage is of the order of 0.5 hours and the production rhythm of this it ends up being a lot but high. Due to this necessity it was thought about the problem of looking by a more efficient monitoring method. In this work a method that uses a detector of NaI (Tl) of 5 x 5 inches is discussed. (Author)

  13. Monitoring of garbage with a 5 x 5 NaI (Tl) detector; Monitoreo de basura con un detector de NaI (Tl) de 5 x 5

    Energy Technology Data Exchange (ETDEWEB)

    Cortes P, A; Becerril V, A; Angeles C, A

    1991-12-15

    So far in that is carried out the first reload of nuclear fuel in the LVC, the monitoring of garbage has been carried out using monitors trade mark Eberline model RM 14. The procedure consists in manually monitoring each object and to separate of the considered 'clean' garbage the objects considered as contaminated, which register greater or equal counts to 100 cpm. This way to process was adequate under normal operation conditions, but not in the operation rhythm that implies a bigger maintenance since the time required for monitoring from 5 to 10 kg. of garbage is of the order of 0.5 hours and the production rhythm of this it ends up being a lot but high. Due to this necessity it was thought about the problem of looking by a more efficient monitoring method. In this work a method that uses a detector of NaI (Tl) of 5 x 5 inches is discussed. (Author)

  14. Agronomic Characteristics Related to Grain Yield and Nutrient Use Efficiency for Wheat Production in China.

    Directory of Open Access Journals (Sweden)

    Limin Chuan

    Full Text Available In order to make clear the recent status and trend of wheat (Triticum aestivum L. production in China, datasets from multiple field experiments and published literature were collected to study the agronomic characteristics related to grain yield, fertilizer application and nutrient use efficiency from the year 2000 to 2011. The results showed that the mean grain yield of wheat in 2000-2011 was 5950 kg/ha, while the N, P2O5 and K2O application rates were 172, 102 and 91 kg/ha on average, respectively. The decrease in N and P2O5 and increase in K2O balanced the nutrient supply and was the main reason for yield increase. The partial factor productivity (PFP, kg grain yield produced per unit of N, P2O5 or K2O applied values of N (PFP-N, P (PFP-P and K (PFP-K were in the ranges of 29.5~39.6, 43.4~74.9 and 44.1~76.5 kg/kg, respectively. While PFP-N showed no significant changes from 2000 to 2010, both PFP-P and PFP-K showed an increased trend over this period. The mean agronomic efficiency (AE, kg grain yield increased per unit of N, P2O5 or K2O applied values of N (AEN, P (AEP and K (AEK were 9.4, 10.2 and 6.5 kg/kg, respectively. The AE values demonstrated marked inter-annual fluctuations, with the amplitude of fluctuation for AEN greater than those for AEP and AEK. The mean fertilizer recovery efficiency (RE, the fraction of nutrient uptake in aboveground plant dry matter to the nutrient of fertilizer application values of N, P and K in the aboveground biomass were 33.1%, 24.3% and 28.4%, respectively. It was also revealed that different wheat ecological regions differ greatly in wheat productivity, fertilizer application and nutrient use efficiency. In summary, it was suggested that best nutrient management practices, i.e. fertilizer recommendation applied based on soil testing or yield response, with strategies to match the nutrient input with realistic yield and demand, or provided with the 4R's nutrient management (right time, right rate, right

  15. Toward efficient computation of the expected relative entropy for nonlinear experimental design

    International Nuclear Information System (INIS)

    Coles, Darrell; Prange, Michael

    2012-01-01

    The expected relative entropy between prior and posterior model-parameter distributions is a Bayesian objective function in experimental design theory that quantifies the expected gain in information of an experiment relative to a previous state of knowledge. The expected relative entropy is a preferred measure of experimental quality because it can handle nonlinear data-model relationships, an important fact due to the ubiquity of nonlinearity in science and engineering and its effects on post-inversion parameter uncertainty. This objective function does not necessarily yield experiments that mediate well-determined systems, but, being a Bayesian quality measure, it rigorously accounts for prior information which constrains model parameters that may be only weakly constrained by the optimized dataset. Historically, use of the expected relative entropy has been limited by the computing and storage requirements associated with high-dimensional numerical integration. Herein, a bifocal algorithm is developed that makes these computations more efficient. The algorithm is demonstrated on a medium-sized problem of sampling relaxation phenomena and on a large problem of source–receiver selection for a 2D vertical seismic profile. The method is memory intensive but workarounds are discussed. (paper)

  16. Applications of a pnCCD detector coupled to columnar structure CsI(Tl) scintillator system in ultra high energy X-ray Laue diffraction

    Science.gov (United States)

    Shokr, M.; Schlosser, D.; Abboud, A.; Algashi, A.; Tosson, A.; Conka, T.; Hartmann, R.; Klaus, M.; Genzel, C.; Strüder, L.; Pietsch, U.

    2017-12-01

    Most charge coupled devices (CCDs) are made of silicon (Si) with typical active layer thicknesses of several microns. In case of a pnCCD detector the sensitive Si thickness is 450 μm. However, for silicon based detectors the quantum efficiency for hard X-rays drops significantly for photon energies above 10 keV . This drawback can be overcome by combining a pixelated silicon-based detector system with a columnar scintillator. Here we report on the characterization of a low noise, fully depleted 128×128 pixels pnCCD detector with 75×75 μm2 pixel size coupled to a 700 μm thick columnar CsI(Tl) scintillator in the photon range between 1 keV to 130 keV . The excellent performance of the detection system in the hard X-ray range is demonstrated in a Laue type X-ray diffraction experiment performed at EDDI beamline of the BESSY II synchrotron taken at a set of several GaAs single crystals irradiated by white synchrotron radiation. With the columnar structure of the scintillator, the position resolution of the whole system reaches a value of less than one pixel. Using the presented detector system and considering the functional relation between indirect and direct photon events Laue diffraction peaks with X-ray energies up to 120 keV were efficiently detected. As one of possible applications of the combined CsI-pnCCD system we demonstrate that the accuracy of X-ray structure factors extracted from Laue diffraction peaks can be significantly improved in hard X-ray range using the combined CsI(Tl)-pnCCD system compared to a bare pnCCD.

  17. Point Defect Properties of Cd(Zn)Te and TlBr for Room-Temperature Gamma Radiation Detectors

    Science.gov (United States)

    Lordi, Vincenzo

    2013-03-01

    The effects of various crystal defects in CdTe, Cd1-xZnxTe (CZT), and TlBr are critical for their performance as room-temperature gamma radiation detectors. We use predictive first principles theoretical methods to provide fundamental, atomic scale understanding of the defect properties of these materials to enable design of optimal growth and processing conditions, such as doping, annealing, and stoichiometry. Several recent cases will be reviewed, including (i) accurate calculations of the thermodynamic and electronic properties of native point defects and point defect complexes in CdTe and CZT; (ii) the effects of Zn alloying on the native point defect properties of CZT; (iii) point defect diffusion and binding related to Te clustering in Cd(Zn)Te; (iv) the profound effect of native point defects--principally vacancies--on the intrinsic material properties of TlBr, particularly electronic and ionic conductivity; (v) tailored doping of TlBr to independently control the electronic and ionic conductivity; and (vi) the effects of metal impurities on the electronic properties and device performance of TlBr detectors. Prepared by LLNL under Contract DE-AC52-07NA27344 with support from the National Nuclear Security Administration Office of Nonproliferation and Verification Research and Development NA-22.

  18. Absorbed radiation to the nuclear medicine nurses from patients administered 201Tl and 99mTc- MIBI

    International Nuclear Information System (INIS)

    Sattari, Ali; Dadashzadeh, Simin; Nasiroghli, G.; Firoozabadi, Hasan

    2008-01-01

    People who have administrated radiopharmaceuticals could be a source of radiation to their relatives, medical nurses, and people who have contact them. In this study, the dose rates at various distances of 5, 10,50 and 100 cm from 70 patients, who were administered diagnostic amounts of 201 Tl -Chloride and 99m Tc -MIBI, was measured using an ionization chamber. For determination of external radiation dose to the nurses the radiations in three deferent interval times have measured. The maximum values of external dose rates of 201 Tl and 99m Tc-MIBI were 11.2μSv/h ±2.3 and 43.1μSv/h ±11.9 respectively at 5 cm from the patients. Significant exposure from patients after injection of 99m Tc -MIBI was limited on the day of administration. Departure doses rate of 201 Tl fell gradually so by 3 days after administration was significant. Maximum and average absorbed dose of nuclear medicine staff for one 201 Tl scan was 4.6 and 2.7μSv/h, and for 99m Tc-MIBI was 18.1 and 9.8μSv/h in a working day. (author)

  19. Evaluation of myocardial disorders in patients with dilated cardiomyopathy and left ventricular eccentric hypertrophy; By sup 201 Tl myocardial SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Yamazaki, Junichi; Ohsawa, Hidefumi; Uchi, Takashi (Toho Univ., Tokyo (Japan). School of Medicine) (and others)

    1992-03-01

    {sup 201}Tl myocardial SPECT was performed in cases of dilated cardiomyopathy and valvular heart disease with left ventricular eccentric hypertrophy, and the two groups were compared from the standpoint of the mechanism of onset of myocardial disorders. Significant coefficients of correlation were seen between the Tl score and LVDd (r=0.792, r=0.785) and Tl score and LVEF (r=-0.634, r=-0.555) in both dilated cardiomyopathy and valvular heart disease. In cases of valvular heart disease, significant correlation coefficients (r=-0.756, r=-0.720) between LVDd and r-WR (relative-washout rate), and Tl score and r-WR were observed, but no such correlation was seen in dilated cardiomyopathy. In valvular heart disease, a decrease in myocardial perfusion associated with enlargement of the left ventricle appeared, while in dilated cardiomyopathy, there was a marked decrease in LVEF in proportion to the thallium defect. Therefore, it was assumed that left ventricular wall disorders occur due to myocardial metabolic disorders and coronary microcirculation disorders. (author).

  20. TlHgInS 3 : An Indirect-Band-Gap Semiconductor with X-ray Photoconductivity Response

    Energy Technology Data Exchange (ETDEWEB)

    Li, Hao; Malliakas, Christos D.; Han, Fei; Chung, Duck Young; Kanatzidis, Mercouri G.

    2015-08-11

    The quaternary compound TlHgInS3 crystallizes in a new structure type of space group, C2/c, with cell parameters a = 13.916(3) angstrom, b = 3.9132(8) angstrom, c = 21.403(4) angstrom, beta = 104.16(3)degrees, V = 1130.1(8) angstrom(3), and rho = 7.241 g/cm(3). The structure is a unique three-dimensional framework with parallel tunnels, which is formed by (1)(infinity)[InS33-] infinite chains bridged by linearly coordinated Hg2+ ions. TlHgInS3 is a semiconductor with a band gap of 1.74 eV and a resistivity of similar to 4.32 G Omega cm. TlHgInS3 single crystals exhibit photocurrent response when exposed to Ag X-rays. The mobility-lifetime product (mu tau) of the electrons and holes estimated from the photocurrent measurements are (mu tau)(e) approximate to 3.6 x 10(-4) cm(2)/V and (mu tau)(h) approximate to 2.0 x 10(-4) cm(2)/V. Electronic structure calculations at the density functional theory level indicate an indirect band gap and a relatively small effective mass for both electrons and holes. Based on the photoconductivity data, TlHgInS3 is a potential material for radiation detection applications.

  1. How phonological awareness mediates the relation between working memory and word reading efficiency in children with dyslexia.

    Science.gov (United States)

    Knoop-van Campen, Carolien A N; Segers, Eliane; Verhoeven, Ludo

    2018-05-01

    This study examined the relation between working memory, phonological awareness, and word reading efficiency in fourth-grade children with dyslexia. To test whether the relation between phonological awareness and word reading efficiency differed for children with dyslexia versus typically developing children, we assessed phonological awareness and word reading efficiency in 50 children with dyslexia (aged 9;10, 35 boys) and 613 typically developing children (aged 9;5, 279 boys). Phonological awareness was found to be associated with word reading efficiency, similar for children with dyslexia and typically developing children. To find out whether the relation between working memory and word reading efficiency in the group with dyslexia could be explained by phonological awareness, the children with dyslexia were also tested on working memory. Results of a mediation analysis showed a significant indirect effect of working memory on word reading efficiency via phonological awareness. Working memory predicted reading efficiency, via its relation with phonological awareness in children with dyslexia. This indicates that working memory is necessary for word reading efficiency via its impact on phonological awareness and that phonological awareness continues to be important for word reading efficiency in older children with dyslexia. © 2018 The Authors Dyslexia Published by John Wiley & Sons Ltd.

  2. How the sedimentary Re/Mo ratio and Tl enrichments trace past and present opaline productivity

    Science.gov (United States)

    Böning, Philipp; Brumsack, Hans-Jürgen

    2010-05-01

    preconcentration step for Mo on particles to explain the very low Re/Mo ratios, while Re only seems to accumulate via diffusion. However, our data suggest that the carrier phases are not Mn-oxides but fresh biogenic detritus. Further, since Mo and Cd are well correlated (Böning et al., 2004) our findings suggest a similar, biodetrital source for both elements. This would imply a non-conservative behaviour of Mo, which corroborates findings where dissolved Mo becomes depleted in coastal and open-ocean waters and consequently enriched on biogenic particles after algal blooms (Tuit and Ravizza, 2003; Dellwig et al. 2007). Concerning Tl, it is yet to be determined wether this element is directly associated with the opaline hard parts or the related fresh organic matter. However, the implied particle reactivity of Tl suggests a non-conservative behaviour of this element. Further, our data do not support an involvement of Tl with Mn but rather an association with biological cycling. References: Böning, P. et al. (2009) Mar. Geol. 259, 112-121; Böning, P. et al. (2004) Geochim. Cosmochim. Acta 68, 4429-4451; Crusius, J. et al. (1996) Earth Plan. Sci. Lett. 145, 65-78; Dellwig, O. et al. (2007) Geochim. Cosmochim. Acta 71, 2745-2761; Tuit, C. and Ravizza, G. (2003) Geochim. Cosmochim. Acta 67, A495, Suppl. 1; Wolf, A. (2002) Dissertation, University of Kiel, Germany, pp. 88.

  3. Experimental studies on radiation damages of CsI(Tl) crystals

    International Nuclear Information System (INIS)

    He Jingtang; Mao Yufang; Dong Xiaoli; Chen Duanbao; Li Zuhao

    1997-01-01

    The results of experimental studies on radiation damage of CsI(Tl) crystal were reported. There are radiation damage effects on CsI(Tl) crystal. Experimental studies on recovery of damaged CsI(Tl) crystals were made. It seems that after heating at 200 degree C for 4 hours, the damaged crystals could be recovered completely

  4. Left ventricular ejection fraction determined by gated Tl-201 perfusion SPECT and quantitative software

    International Nuclear Information System (INIS)

    Hyun, In Young; Kim, Sung Eun; Seo, Jeong Kee; Hong, Eui Soo; Kwan, Jun; Park, Keum Soo; Lee, Woo Hyung

    2000-01-01

    We compared estimates of ejection fraction (EF) determined by gated Tl-201 perfusion SPECT (g-Tl-SPECT) with those by gated blood pool (GBP) scan. Eighteen subjects underwent g-Tl-SPECT and GBP scan. After reconstruction of g-Tl-SPECT, we measured EF with Cedars software. The comparison of the EF with g-Tl-SPECT and GBP scan was assessed by correlation analysis and Bland Altman plot. The estimates of EF were significantly different (p<0.05) with g-Tl-SPECT (40%±14%) and GBP scan (43%±14%). There was an excellent correlation of EF between g-Tl-SPECT and GBP scan (r=3D0.94, p<0.001). The mean difference of EF between GBP scan and g-Tl-SPECT was +3.2%. Ninety-five percent limits of agreement were ±9.8%. EF between g-Tl-SPECT and GBP scan were in poor agreement. The estimates of EF by g-Tl-SPECT was well correlated with those by GBP scan. However, EF of g-Tl-SPECT doesn't agree with EF of GBP scan. EF of g-Tl-SPECT can't be used interchangeably with EF of GBP scan.=20

  5. Challenges to Disciplinary Knowing and Identity: Experiences of Scholars in a SoTL Development Program

    Science.gov (United States)

    Miller-Young, Janice E.; Yeo, Michelle; Manarin, Karen

    2018-01-01

    Faculty members from five years of an annual Scholarship of Teaching and Learning (SoTL) development program were invited to participate in a study about the impact of SoTL on their teaching, scholarship, and career trajectory. During semi-structured interviews, many expressed feeling discomfort during their journey into SoTL. A qualitative…

  6. High current Tl-203, Rh-103 targets preparation for cyclotron production of Tl-201 and Pd-103 radionuclides

    International Nuclear Information System (INIS)

    Arzumanov, A.; Berger, V.; Borissenko, A.; Gorodisskaya, N.; Ilmatov, I.; Knyazev, A.; Koptev, V.; Lyssukhin, S.; Platov, A.; Sychikov, G.; Zheltov, D.

    2004-01-01

    The objectives of the present work are to increase thermal stability of cyclotron targets for production of Tl-201 isotope, increase Tl-203 regeneration rate at radiochemical reprocessing of the targets and develop production technology for radiochemical sources based on Rd-103 isotope. Electrochemical coating of copper substrate with Tl increased the beam current at target irradiation from 100 μA to 125 μA. Further increase of the beam current results in sharp decrease of target stability time at irradiation to 15 min at beam current 150 μA. Thermal calculations and tests at the electron-beam stand predict satisfactory stability at such currents. The discrepancy with the irradiation results has not been explained. More accurate specification of regimes for Tl-203 electrochemical recovery from irradiated targets and better matching of the electrolyte composition made it possible to increase the recovery rate up to 99.5%. Before the present Project, the INP had no experience in production of radioactive sources based on Pd-103. Thermo-diffusion extraction of Pd-103 from irradiated rhodium foil has been chosen as a technology-defining method. The process assures good extraction rate and high purity of extracted isotope. Production of Pd-103 sources based on this technology is much simpler compared to the same based on electrochemical processes. (author)

  7. Morphometric relations in the grey eel catfish Plotosus canius in the coastal waters of Port Dickson, Peninsular Malaysia.

    Science.gov (United States)

    Usman, B I; Amin, S M N; Arshad, A; Kamarudin, M S

    2016-07-01

    Samples of grey eel catfish Plotosus canius were collected from the coastal waters of Port Dickson, Malaysia from January to December, 2012. A total of 341 specimens (172 males and 169 females) were used to estimate the length-weight relationship parameters. Mean population size of females were 0.72 cm taller than the males, however difference was not significant (t-test, P > 0.05). The overall relationship equations between total length (TL) and body weight (BW) were established for males as Log TW = 2.71 Log TL - 1.85 (R2 = 0.95) and for females as Log TW = 2.88 Log TL-2.10 (R2 = 0.95). The estimated relative growth co-efficient (b) values were 2.71 for males and 2.88 for females. It is revealed that growth pattern of the species showed negative allometry. In both males and females, relationship between TL and SL gave highest regression coefficient (0.99). While relationship between TL and EL gave lowest regression coefficient in both males and females (0.87 and 0.81 respectively). The findings from this study contributed first information on morphometric relations of the fish from Malaysian coastal waters and could be useful for sustainable management options of P. canius in Malaysia.

  8. Utility and performance relative to consumer product energy efficiency standards. Final technical report

    Energy Technology Data Exchange (ETDEWEB)

    Coggins, J.L.

    1979-12-14

    An investigation of the relative utility and performance of nine major household consumer products covered by the Energy Policy and Conservation Act is summarized. The objective was to define the terms utility and performance, to recommend methods for quantifying these two concepts, and to recommend an approach for dealing with utility and performance issues in the energy efficiency standards program. The definitions developed are: performance of a consumer product is the objective measure of how well, with the expected level of consumer input (following the manufacturer's instructions for installation and operation), the product does its intended job; and utility of a consumer product is a subjective measure, based on the consumer's perception, of the capability of the product to satisfy human needs. Quantification is based on test procedures and consumer survey methods which are largely already in use by industry. Utility and performance issues are important in product classification for prescribing energy efficiency standards. The recommended approach to utility and performance issues and classification is: prior to setting standards, evaluate utility and performance issues in the most quantitative way allowed by resources and schedules in order to develop classification guidelines. This approach requires no changes in existing Department of Energy test procedures.

  9. Photophysical and photochemical study of styrene dyes related to their laser efficiency

    International Nuclear Information System (INIS)

    Meyer, Martine

    1989-01-01

    The photophysical and photochemical properties of two styrene dyes: 4-dicyanomethylene-2-methyl-6-p-dimethylamino-styryl-4H-pyran (DCM) and 7-dimethylamino-3-(-p-formyl-styryl)-1,4-benzoxazine-2-one (DFSBO) have been studied. These molecules have electron donor and electron acceptor groups which give to their fluorescent excited state a charge transfer state character. The red shifts of the absorption and fluorescence spectra in polar solvents and the large Stokes shift related to the increase of the dipole moment from the ground state to the singlet excited state have been fully characterised. The absorption spectra of the first excited singlet and triplet states and the quantum yields of the intersystem crossing to the triplet state have been determined. The existence of conformers of the two dyes has been evidenced. The synthesis of DCM leads to the trans isomer which, under light exposure undergoes photo-isomerization to the cis-compound. Their fluorescence lifetimes and the photo-isomerization efficiency are solvent dependent. The DFSBO emission spectra depend greatly on the excitation wavelength. This effect can be explained by the occurrence of two rotational conformers one being stabilised by an intramolecular hydrogen bond. The spectral properties of these two molecules enable us to explain why DCM is a very good laser dye whereas DFSBO has a poor laser efficiency. (author) [fr

  10. Novel Approach to Increase the Energy-related Process Efficiency and Performance of Laser Brazing

    Science.gov (United States)

    Mittelstädt, C.; Seefeld, T.; Radel, T.; Vollertsen, F.

    Although laser brazing is well established, the energy-related efficiency of this joining method is quite low. That is because of low absorptivity of solid-state laser radiation, especially when copper base braze metals are used. Conventionally the laser beam is set close to the vertical axis and the filler wire is delivered under a flat angle. Therefore, the most of the utilized laser power is reflected and thus left unexploited. To address this situation an alternative processing concept for laser brazing, where the laser beam is leading the filler wire, has been investigated intending to make use of reflected shares of the laser radiation. Process monitoring shows, that the reflection of the laser beam can be used purposefully to preheat the substrate which is supporting the wetting and furthermore increasing the efficiency of the process. Experiments address a standard application from the automotive industry joining zinc coated steels using CuSi3Mn1 filler wire. Feasibility of the alternative processing concept is demonstrated, showing that higher processing speeds can be attained, reducing the required energy per unit length while maintaining joint properties.

  11. A clinical study of gated simultaneous rest 201Tl/stress 99Tcm-sestamibi dual isotope myocardial perfusion imaging

    International Nuclear Information System (INIS)

    Tang Anwu; Qiao Shuixian; Luo Yaowu; Liang Xiaolin

    2002-01-01

    Objective: To investigate a modified gated radionuclide myocardial tomography in methodology for raising the sensitivity and efficiency of detecting myocardial ischemia. Methods: One hundred and three patients were involved and divided into two groups: coronary artery disease (CAD) patient 37, non-CAD patient 66. 201 Tl 111 MBq was injected intravenously 5 min before stress, the patient exercised with ergometer following the modified Bruce protocol, and was injected 99 Tc m -sestamibi at the peak of stress. 45 min later, the simultaneous dual energy peak gated acquisition was then performed. Stress ( 99 Tc m -sestamibi) and rest ( 201 Tl) images were reconstructed. Results: Positive findings were seen in 35/37 (94.6%) in CAD group and 7/66 (10.6%) in non-CAD, respectively; LVEF, EDV and ESV of two groups were (52.33+-16.26)%, (70.45+-28.12) mL, (33.35 +- 18.86) mL and (61.76 +- 9.38)%, (60.45 +- 18.18) mL, (23.30 +- 11.09) mL, respectively. Conclusion: The simultaneous stress ( 99 Tc m -sestamibi) and rest ( 201 Tl) gated myocardial imaging is an efficient and practical protocol for the study of myocardial perfusion and the diagnosis of ischemia

  12. Importance of controlling the Tl-oxide partial pressure throughout the processing of TlBa2CaCu2O7 thin films

    International Nuclear Information System (INIS)

    Siegal, M.P.; Venturini, E.L.; Newcomer, P.P.; Overmyer, D.L.; Dominguez, F.; Dunn, R.

    1995-01-01

    TlBa 2 CaCu 2 O 7 (Tl-1212) superconducting films 5000--6000 A thick have been grown on LaAlO 3 (100) substrates using oxide precursors in a closed two-zone thallination furnace. Tl-1212 films can be grown with transition temperatures ∼100 K, and critical current densities measured by magnetization of J cm (5 K)>10 7 A/cm 2 and J cm (77 K)>10 5 A/cm 2 . Processing conditions, substrate temperatures and Tl-oxide source temperatures are found which result in smooth, nearly phase-pure Tl-1212 films. Variations in the respective temperature ramps of the Tl-oxide zone and the substrate zone can greatly influence resulting film properties such as microstructure, morphology, superconducting transition temperature, and critical current density. copyright 1995 American Institute of Physics

  13. Efficient approximations of dispersion relations in optical waveguides with varying refractive-index profiles.

    Science.gov (United States)

    Li, Yutian; Zhu, Jianxin

    2015-05-04

    In this paper we consider the problem of computing the eigen-modes for the varying refractive-index profile in an open waveguide. We first approximate the refractive-index by a piecewise polynomial of degree two, and the corresponding Sturm-Liouville problem (eigenvalue problem) of the Helmholtz operator in each layer can be solved analytically by the Kummer functions. Then, analytical approximate dispersion equations are established for both TE and TM cases. Furthermore, the approximate dispersion equations converge fast to the exact ones for the continuous refractive-index function as the maximum value of the subinterval sizes tends to zero. Suitable numerical methods, such as Müller's method or the chord secant method, may be applied to the dispersion relations to compute the eigenmodes. Numerical simulations show that our method is very practical and efficient for computing eigenmodes.

  14. THE EFFICIENCY OF PROMOTIONAL INSTRUMENTS RELATED TO THE PRODUCT LIFE CYCLE STAGES

    Directory of Open Access Journals (Sweden)

    MIHAELA MARCU

    2010-01-01

    Full Text Available Regarded as a planning tool, PLC (product life cycle strongly contributes to the identification of the main marketing challenges that may arise throughout the life of a product/service. Thus, the marketing management has the opportunity to develop and implement those solutions designed to optimize each of the 4P of marketing mix: product (quality, price, distribution (placement and promotion. The communication program has an essential role, because the company presents through it its "product" to actual or potential customers in order to convince them of the benefits of purchasing/using it. The efficiency of the promotional instruments involves an appropriate allocation of funds needed to promote the product/service in relation to the stage of its life cycle.

  15. Fuel efficiency of conventional design tractors diesel engines in relation to new design

    Directory of Open Access Journals (Sweden)

    Jevtić Jeremija

    2006-01-01

    Full Text Available Total consumption of all types of energies is rather high nowadays with constant tendency of increasing. Transport section is one of the highest consumers of energy obtained from fossil fuels. It is absolutely clear that the reduction of energy consumption and the protection of environment - exhaust emission reduction, i. e. cleaner air, will be one of the main tasks of automotive industry in the first decades of the 21st century. In spite of its superiority over the petrol engine in respect of the fuel consumption, a diesel engine "suffers" from the increased exhaust emission, particles and NOx first of all and also from the noise and vibrations. The paper gives a review of fuel efficiency of conventional design tractors diesel engines in relation to new design. .

  16. Experimental determination of relative light conversion factors of TLD-100 for protons with energies from 2.0 to 9.0 MeV

    International Nuclear Information System (INIS)

    Schmidt, P.; Fellinger, J.; Henniger, J.; Huebner, K.

    1988-01-01

    The efficiency of thermoluminescent (TL) detectors to heavy charged particles is described by the so-called light conversion factor η. Relative light conversion factors for protons, alphas and heavier recoils are needed for the calculation of the neutron sensitivity of TL detectors. Such light conversion factors can be determined experimentally. In this paper a method is presented for the experimental determination of relative light conversion factors. Using the experimental arrangement described, relative light conversion factors for LiF material (TLD-100) for protons were determined. In LiF the relative main peak (peak V) efficiency is always lower than 1. It increases with increasing proton energy whereas the relative efficiency of the high temperature peak (peak VI) shows an opposite dependence on the proton energy. Relative light conversion factors for peak VI clearly exceed 1. (orig.)

  17. Spectrum analysis with indoor multi-channels gamma-rays spectrometer (NaI(Tl))

    International Nuclear Information System (INIS)

    Hou Shengli; Fan Weihua

    2005-01-01

    Two calculational methods for analyzing the spectrum which measured by indoor low background multi-channels gamma-rays spectrometer (Na(Tl)) to get the specific activity of 226 Ra, 232 Th and 40 K of the sample are discussed, they are the spectrum analysis method and the characteristic energy peak method (inverse matrix method) respectively. The sample spectrum are analyzed with the program designed according to the two methods, and compared with the results by HPGe gamma-rays spectrometer, showing that the relative deviation is ≤10% with the two methods. (authors)

  18. Time of gamma radiation transport in NaI(Tl) scintillators

    International Nuclear Information System (INIS)

    Matarrita, A.S.

    1976-01-01

    The distribution of time intervals in function of the energy, ocurred between the incidence of a gamma radiation in the face of a scintillation crystal and the arrival of the correspondent scintillation at photocathode, is calculated. The mean square fluctuation these time interval, relating to resolution of the detector system is determined. The calculations are done for NaI (Tl) cylindrical crystals with the radiation source placed in the symmetry axis, in two situations: para axial incidence and oblique incidence, indicating a good agreement with experimental data. (M.C.K.) [pt

  19. Sensory Gain Outperforms Efficient Readout Mechanisms in Predicting Attention-Related Improvements in Behavior

    Science.gov (United States)

    Ester, Edward F.; Deering, Sean

    2014-01-01

    Spatial attention has been postulated to facilitate perceptual processing via several different mechanisms. For instance, attention can amplify neural responses in sensory areas (sensory gain), mediate neural variability (noise modulation), or alter the manner in which sensory signals are selectively read out by postsensory decision mechanisms (efficient readout). Even in the context of simple behavioral tasks, it is unclear how well each of these mechanisms can account for the relationship between attention-modulated changes in behavior and neural activity because few studies have systematically mapped changes between stimulus intensity, attentional focus, neural activity, and behavioral performance. Here, we used a combination of psychophysics, event-related potentials (ERPs), and quantitative modeling to explicitly link attention-related changes in perceptual sensitivity with changes in the ERP amplitudes recorded from human observers. Spatial attention led to a multiplicative increase in the amplitude of an early sensory ERP component (the P1, peaking ∼80–130 ms poststimulus) and in the amplitude of the late positive deflection component (peaking ∼230–330 ms poststimulus). A simple model based on signal detection theory demonstrates that these multiplicative gain changes were sufficient to account for attention-related improvements in perceptual sensitivity, without a need to invoke noise modulation. Moreover, combining the observed multiplicative gain with a postsensory readout mechanism resulted in a significantly poorer description of the observed behavioral data. We conclude that, at least in the context of relatively simple visual discrimination tasks, spatial attention modulates perceptual sensitivity primarily by modulating the gain of neural responses during early sensory processing PMID:25274817

  20. Stability of Tl(III) in the context of speciation analysis of thallium in plants.

    Science.gov (United States)

    Sadowska, Monika; Biaduń, Ewa; Krasnodębska-Ostręga, Beata

    2016-02-01

    The paper presents both "good" and "bad" results obtained during speciation analysis of thallium in plant tissues of a hyperaccumulator of this metal. The object was white mustard - Sinapis alba L. In this plant there were found traces of trivalent thallium. The crucial point of this study (especially in the case of so unstable thallium form as Tl(III)) was to prove that the presence of Tl(III) was not caused by the procedure of sample preparation itself, and that the whole analytical method provides reliable results. Choice of the method for conservation of the initial speciation, extraction with the highest efficiency and proving the correctness of the obtained data were the most difficult parts of the presented study. It was found that: both freezing and drying cause significant changes in the speciation of thallium; quantitative analysis could be performed only with fresh tissues of mustard plants; only short-term storage of an extract from fresh plant tissues is possible; the methodology is not the source of thallium (III); only the presence of DTPA can greatly limit the reduction of TI(III) to TI(I) (up to 1-3%); the UV irradiation results in disintegration of TI(III)DTPA in the presence of plant matrix (reduction up to 90%). Copyright © 2015 Elsevier Ltd. All rights reserved.

  1. Mechanisms of TL for production of the 230 {sup o}C peak in natural sodalite

    Energy Technology Data Exchange (ETDEWEB)

    Cano, Nilo F., E-mail: nilocano@dfn.if.usp.b [Institute of Physics, University of Sao Paulo, Rua do Matao, Travessa R, 187, CEP 05508-090, Sao Paulo (Brazil); Professional School of Physics, University of San Agustin of Arequipa, Av. Independencia S/N, Arequipa (Peru); Blak, Ana R. [Institute of Physics, University of Sao Paulo, Rua do Matao, Travessa R, 187, CEP 05508-090, Sao Paulo (Brazil); Ayala-Arenas, Jorge S. [Professional School of Physics, University of San Agustin of Arequipa, Av. Independencia S/N, Arequipa (Peru); Watanabe, Shigueo [Institute of Physics, University of Sao Paulo, Rua do Matao, Travessa R, 187, CEP 05508-090, Sao Paulo (Brazil)

    2011-02-15

    The thermoluminescence (TL) peak in natural sodalite near 230 {sup o}C, which appears only after submitted to thermal treatments and to gamma irradiation, has been studied in parallel with electron paramagnetic resonance (EPR) spectrum appearing under the same procedure. This study revealed a full correlation between the 230 {sup o}C TL peak and the eleven hyperfine lines from EPR spectrum. In both case, the centers disappear at the same temperature and are restored after gamma irradiation. A complete model for the 230 {sup o}C TL peak is presented and discussed. In addition to the correlation and TL model, specific characteristics of the TL peaks are described.

  2. Electronic band structure study of colossal magnetoresistance in Tl 2Mn 2O 7

    Science.gov (United States)

    Seo, D.-K.; Whangbo, M.-H.; Subramanian, M. A.

    1997-02-01

    The electronic structure of Tl 2Mn 2O 7 was examined by performing tight binding band calculations. The overlap between the Mn t 2g- and Tl 6 s-block bands results in a partial filling of the Tl 6 s-block bands. The associated Fermi surface consists of 12 cigar-shape electron pockets with each electron pocket about {1}/{1000} of the first Brillouin zone in size. The Tl 6 s-block bands have orbital contributions from the Mn atoms, and the carrier density is very low. These are important for the occurrence of a colossal magnetoresistance in Tl 2Mn 2O 7.

  3. Relations between the efficiency, power and dissipation for linear irreversible heat engine at maximum trade-off figure of merit

    Science.gov (United States)

    Iyyappan, I.; Ponmurugan, M.

    2018-03-01

    A trade of figure of merit (\\dotΩ ) criterion accounts the best compromise between the useful input energy and the lost input energy of the heat devices. When the heat engine is working at maximum \\dotΩ criterion its efficiency increases significantly from the efficiency at maximum power. We derive the general relations between the power, efficiency at maximum \\dotΩ criterion and minimum dissipation for the linear irreversible heat engine. The efficiency at maximum \\dotΩ criterion has the lower bound \

  4. Drawing skill is related to the efficiency of encoding object structure.

    Science.gov (United States)

    Perdreau, Florian; Cavanagh, Patrick

    2014-01-01

    Accurate drawing calls on many skills beyond simple motor coordination. A good internal representation of the target object's structure is necessary to capture its proportion and shape in the drawing. Here, we assess two aspects of the perception of object structure and relate them to participants' drawing accuracy. First, we assessed drawing accuracy by computing the geometrical dissimilarity of their drawing to the target object. We then used two tasks to evaluate the efficiency of encoding object structure. First, to examine the rate of temporal encoding, we varied presentation duration of a possible versus impossible test object in the fovea using two different test sizes (8° and 28°). More skilled participants were faster at encoding an object's structure, but this difference was not affected by image size. A control experiment showed that participants skilled in drawing did not have a general advantage that might have explained their faster processing for object structure. Second, to measure the critical image size for accurate classification in the periphery, we varied image size with possible versus impossible object tests centered at two different eccentricities (3° and 8°). More skilled participants were able to categorise object structure at smaller sizes, and this advantage did not change with eccentricity. A control experiment showed that the result could not be attributed to differences in visual acuity, leaving attentional resolution as a possible explanation. Overall, we conclude that drawing accuracy is related to faster encoding of object structure and better access to crowded details.

  5. Masticatory efficiency and oral health-related quality of life with implant-retained mandibular overdentures

    Science.gov (United States)

    Sun, Xu; Zhai, Jun-Jiang; Liao, Jian; Teng, Min-Hua; Tian, Ai; Liang, Xing

    2014-01-01

    Objectives: To evaluate masticatory efficiency (ME) and oral health-related quality of life (OHRQoL) in patients rehabilitated with implant-retained mandibular overdentures. Methods: In this randomized controlled clinical trial, 50 edentulous patients visiting the Implant Center and Department of Prosthodontics, West China College of Stomatology, Sichuan University, Chengdu, China between June 2010 and June 2012 were selected and received 2 implant-retained mandibular overdenture treatments. All patients were rehabilitated with maxillary complete dentures. The ME and OHRQoL were determined both one month before the mandibular complete denture was anchored to the osseointegrated implants, and 6 months after anchoring. Paired t-tests were used to compare means of ME, and oral health impact profile-49 (OHIP-49) domains scores between pre- and post-implant. Linear regression models were utilized to seek correlations between ME and OHIP domains scores. Results: The ME increased from pre- to post-implant retained mandibular overdentures significantly (p<0.001). The total OHIP score and 4 subscales scores were changed significantly from pre- to post-implant; namely, functional limitation, psychological discomfort, physical disability, and physical pain. The total OHIP score, functional limitation, physical disability, and physical pain subscale scores were related to ME. Conclusion: Implant-retained mandibular over dentures can significantly improve patients’ ME and OHRQoL. The improvement in OHRQoL is mainly because of the improved ME. An improved chewing experience, and pain relief also contributes to improvement of OHRQoL. PMID:25316463

  6. Two crystal structures of Ag sup + -and Tl sup + -exchanged zeolite X, Ag sub 2 sub 7 Tl sub 6 sub 5 -X and Ag sub 2 sub 3 Tl sub 6 sub 9 -X

    CERN Document Server

    Kim, S Y; Kim, Y

    2002-01-01

    Two crystal structures of dehydrated Ag sup + -and Tl sup + -exchanged zeolite X (Ag sub 2 sub 7 Tl sub 6 sub 5 -X and Ag sub 2 sub 3 Tl sub 6 sub 9 -X) have been determined by single-crystal X-ray diffraction techniques in the cubic space group Fd3 at 21(1) .deg. C (a = 24.758(4) A, a = 24.947(4) A, respectively). Their structures were refined to the final error indices R sub 1 = 0.055 and wR sub 2 = 0.057 with 375 reflections, and R sub 1 = 0.058 and wR sub 2 = 0.057 with 235 reflections, respectively, for which I> 3 sigma(I). In the structure of Ag sub 2 sub 7 Tl sub 6 sub 5 -X, 27 Ag sup + ions were found at two crystallographic sites: 15 Ag sup + ions at site I at the center of the hexagonal prism and the remaining 12 Ag sup + ions at site II' in the sodalite cavity. Sixty-five Tl sup + ions were located at three crystallographic sites: 20 Tl sup + ions at site II opposite single six-rings in the supercage, 18 Tl sup + ions at site I' in the sodalite cavity opposite the D6Rs, and the remaining 27 Tl sup ...

  7. Least square methods and covariance matrix applied to the relative efficiency calibration of a Ge(Li) detector

    International Nuclear Information System (INIS)

    Geraldo, L.P.; Smith, D.L.

    1989-01-01

    The methodology of covariance matrix and square methods have been applied in the relative efficiency calibration for a Ge(Li) detector apllied in the relative efficiency calibration for a Ge(Li) detector. Procedures employed to generate, manipulate and test covariance matrices which serve to properly represent uncertainties of experimental data are discussed. Calibration data fitting using least square methods has been performed for a particular experimental data set. (author) [pt

  8. Efficient Storage and Querying of Horizontal Tables Using a PIVOT Operation in Commercial Relational DBMSs

    Science.gov (United States)

    Shin, Sung-Hyun; Moon, Yang-Sae; Kim, Jinho; Kim, Sang-Wook

    In recent years, a horizontal table with a large number of attributes is widely used in OLAP or e-business applications to analyze multidimensional data efficiently. For efficient storing and querying of horizontal tables, recent works have tried to transform a horizontal table to a traditional vertical table. Existing works, however, have the drawback of not considering an optimized PIVOT operation provided (or to be provided) in recent commercial RDBMSs. In this paper we propose a formal approach that exploits the optimized PIVOT operation of commercial RDBMSs for storing and querying of horizontal tables. To achieve this goal, we first provide an overall framework that stores and queries a horizontal table using an equivalent vertical table. Under the proposed framework, we then formally define 1) a method that stores a horizontal table in an equivalent vertical table and 2) a PIVOT operation that converts a stored vertical table to an equivalent horizontal view. Next, we propose a novel method that transforms a user-specified query on horizontal tables to an equivalent PIVOT-included query on vertical tables. In particular, by providing transformation rules for all five elementary operations in relational algebra as theorems, we prove our method is theoretically applicable to commercial RDBMSs. Experimental results show that, compared with the earlier work, our method reduces storage space significantly and also improves average performance by several orders of magnitude. These results indicate that our method provides an excellent framework to maximize performance in handling horizontal tables by exploiting the optimized PIVOT operation in commercial RDBMSs.

  9. Research ethics committee decision-making in relation to an efficient neonatal trial.

    Science.gov (United States)

    Gale, C; Hyde, M J; Modi, N

    2017-07-01

    Randomised controlled trials, a gold-standard approach to reduce uncertainties in clinical practice, are growing in cost and are often slow to recruit. We determined whether methodological approaches to facilitate large, efficient clinical trials were acceptable to UK research ethics committees (RECs). We developed a protocol in collaboration with parents, for a comparative-effectiveness, randomised controlled trial comparing two widely used blood transfusion practices in preterm infants. We incorporated four approaches to improve recruitment and efficiency: (i) point-of-care design using electronic patient records for patient identification, randomisation and data acquisition, (ii) short two-page information sheet; (iii) explicit mention of possible inclusion benefit; (iv) opt-out consent with enrolment as the default. With the support of the UK Health Research Authority, we submitted an identical protocol to 12 UK REC. RECs in the UK. Number of REC granting favourable opinions. The use of electronic patient records was acceptable to all RECs; one REC raised concerns about the short parent information sheet, 10 about inclusion benefit and 9 about opt-out consent. Following responses to queries, nine RECs granted a favourable final opinion and three rejected the application because they considered the opt-out consent process invalid. A majority of RECs in this study consider the use of electronic patient record data, short information sheets, opt-out consent and mention of possible inclusion benefit to be acceptable in neonatal comparative-effectiveness research. We identified a need for guidance for RECs in relation to opt-out consent processes. These methods provide opportunity to facilitate large randomised controlled trials. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  10. Transpiration efficiency of a tropical pioneer tree (Ficus insipida) in relation to soil fertility.

    Science.gov (United States)

    Cernusak, Lucas A; Winter, Klaus; Aranda, Jorge; Turner, Benjamin L; Marshall, John D

    2007-01-01

    The response of whole-plant water-use efficiency, termed transpiration efficiency (TE), to variation in soil fertility was assessed in a tropical pioneer tree, Ficus insipida Willd. Measurements of stable isotope ratios (delta(13)C, delta(18)O, delta(15)N), elemental concentrations (C, N, P), plant growth, instantaneous leaf gas exchange, and whole-plant water use were used to analyse the mechanisms controlling TE. Plants were grown individually in 19 l pots with non-limiting soil moisture. Soil fertility was altered by mixing soil with varying proportions of rice husks, and applying a slow release fertilizer. A large variation was observed in leaf photosynthetic rate, mean relative growth rate (RGR), and TE in response to experimental treatments; these traits were well correlated with variation in leaf N concentration. Variation in TE showed a strong dependence on the ratio of intercellular to ambient CO(2) mole fractions (c(i)/c(a)); both for instantaneous measurements of c(i)/c(a) (R(2)=0.69, P <0.0001, n=30), and integrated estimates based on C isotope discrimination (R(2)=0.88, P <0.0001, n=30). On the other hand, variations in the leaf-to-air humidity gradient, unproductive water loss, and respiratory C use probably played only minor roles in modulating TE in the face of variable soil fertility. The pronounced variation in TE resulted from a combination of the strong response of c(i)/c(a) to leaf N, and inherently high values of c(i)/c(a) for this tropical tree species; these two factors conspired to cause a 4-fold variation among treatments in (1-c(i)/c(a)), the term that actually modifies TE. Results suggest that variation in plant N status could have important implications for the coupling between C and water exchange in tropical forest trees.

  11. Pulse shape analysis using CsI(Tl) Crystals

    International Nuclear Information System (INIS)

    Silva, J.; Fiori, E.; Loher, B.; Savran, D.; Wirth, R.; Vencelj, M.

    2013-06-01

    The decay time of CsI(Tl) scintillating material consists of more than a single exponential component. The ratio between the intensity of these components varies as a function of the ionizing power of the absorbed particles, such as γ -rays or protons, and the temperature. This property can therefore be used for particle discrimination and for temperature monitoring, using pulse shape analysis. An unsupervised method that uses fuzzy clustering algorithms for particle identification based on pulse shape analysis is presented. The method is applied to discriminate between photon and proton-induced signals in CsI(Tl) scintillator detectors. The first results of a method that uses pulse shape analysis for correcting the temperature-dependent gain effect of the detector are also presented. The method aims at conserving a good energy resolution in a temperature varying environment without the need to measure the temperature of the detector externally (authors)

  12. Statistics and the additive dose method in TL dating

    International Nuclear Information System (INIS)

    Scott, E.M.

    1988-01-01

    Estimation of the palaeo-dose and its associated error in thermoluminescence (TL) dating requires assumptions to be made concerning the error structures of both the TL signal and dose. In this paper, we consider the sensitivity of palaeo-dose estimation to different error structures and describe techniques for estimation of the resultant palaeo-dose errors. We also indicate how the validity of the assumptions may be verified. We have taken the approach that procedures for the analysis of a glow curve at a single temperature must first be proved prior to their inclusion in a full analysis of the glow curves over a series of temperatures. Thus, the paper deals mainly with the analysis of the univariate structure of glow curves, i.e. estimation of the palaeo-dose and error at each temperature, but in the final section of the paper, we discuss briefly the multivariate structure of the results including automatic detection of plateau regions. (author)

  13. A new spectroscopic imager for X-rays from 0.5 keV to 150 keV combining a pnCCD and a columnar CsI(Tl) scintillator

    Science.gov (United States)

    Schlosser, D. M.; Hartmann, R.; Kalok, D.; Bechteler, A.; Abboud, A.; Shokr, M.; Çonka, T.; Pietsch, U.; Strüder, L.

    2017-04-01

    By combining a low noise fully depleted pnCCD detector with a columnar CsI(Tl) scintillator an energy dispersive spatial resolving detector can be realized with a high quantum efficiency in the range from below 0.5 keV to above 150 keV. The used scintillator system increases the pulse height of gamma-rays converted in the CsI(Tl), due to focusing properties of the columnar scintillator structure by reducing the event size in indirect detection mode (conversion in the scintillator). In case of direct detection (conversion in the silicon of the pnCCD) the relative energy resolution is 0.7% at 122 keV (FWHM = 850 eV) and the spatial resolution is less than 75 μm. In case of indirect detection the relative energy resolution, integrated over all event sizes is about 9% at 122 keV with an expected spatial precision of below 75 μm.

  14. Comparison of 201Tl solution sources in UK hospitals, 2001

    International Nuclear Information System (INIS)

    Baker, M.; Woods, M.

    2001-01-01

    During recent years, concerns have been raised within the nuclear medicine field about the accuracy of activity measurements for 201 Tl. And indeed, NPL calibrations repeatedly indicated that the level of impurities present in such samples and the significant amount of activity adsorbed onto the glass wall of the container could produce erroneous results. In addition, the standard P6 vials, in which 201 Tl solution had been previously supplied, were recently replaced with the new ''10R Type 1 plus'' Schott vials. To assess the magnitude of these effects on the accuracy of clinical measurements of the activity of 201 Tl, an intercomparison exercise was conducted between the National Physical Laboratory (NPL), Nycomed-Amersham (NA) and the UK hospital physics community. The majority of the 273 reported results were within the ± 10 % limit of accuracy that hospitals aim to achieve for diagnosis, biased high. The tendency to overestimate the activity was more evident for syringe measurements. The exercise also revealed that the adsorption losses experienced with P6 vials had been solved by the introduction of the 10R vials, but individual calibrators need to be recalibrated for this new container. (author)

  15. Firing temperature of pottery using TL and OSL techniques

    International Nuclear Information System (INIS)

    Polymeris, G.S.; Sakalis, A.; Papadopoulou, D.; Dallas, G.; Kitis, G.; Tsirliganis, N.C.

    2007-01-01

    Several methods of thermal analysis are used to determine in the laboratory the firing temperature of ancient ceramic sherds. These methods are based primarily on changes of physical characteristics occurring when clay minerals are heated. The luminescence properties of quartz grains in a ceramic matrix also undergo certain changes during firing. The possibility of measuring the sensitivity change (sensitization) of quartz in order to determine the firing temperature of archeological ceramic artifacts was investigated. The sensitivity change was studied for both the thermoluminescence (TL) and the optically stimulated luminescence (OSL) signal for a ceramic sample of known firing temperature. Various segments of the sample were annealed to a different temperature. Subsequently, the initial sensitivity, as well as the thermal and the pre-dose sensitization were measured for both TL and OSL at room temperature as a function of the annealing temperature. The obtained TL glow curves showed different shapes for annealing temperatures above the firing temperature. Thermal and pre-dose sensitizations also exhibited a similar, although less prominent, rise. The OSL signal was analyzed by integrating the raw signal over the initial second of stimulation. The initial sensitivity showed an abrupt change for annealing temperatures around the firing temperature. An alternative approach used for the analysis of the OSL signal involved a full-component resolved sensitization study. The same abrupt change for the initial sensitivity of both the first and second components was observed, as well as, a clear but not very prominent thermal sensitization trend for annealing temperatures above the firing temperature

  16. Nuclear resonance fluorescence of {sup 203,205}Tl

    Energy Technology Data Exchange (ETDEWEB)

    Pfeifer, Fabian; Fritzsche, Matthias; Pietralla, Norbert; Savran, Deniz; Weller, Henry; Zweidinger, Markus [Institut fuer Kernphysik, Technische Universitaet, Darmstadt (Germany); Rusev, Gencho; Tonchev, Anton P.; Tornow, Werner [Triangle Universities Nuclear Laboratory, Duke University, Durham (United States); Zilges, Andreas [Institut fuer Kernphysik, Universitaet Koeln (Germany)

    2009-07-01

    In order to investigate the dipole strength distribution in Thalium isotopes we have studied Nuclear Resonance Fluorescence of a sample composed of natural Thallium (consisting of 30% {sup 203}Tl and 70% {sup 205}Tl). Unpolarized bremsstrahlung with photo energies up to 7.5 MeV was used at the High Intensity Photon Setup (HIPS) at S-DALINAC at the IKP Darmstadt. 24 fluorescent {gamma}-ray transitions were observed, 19 of them for the first time. For the assignment of the polarity of two prominent {gamma}-ray transitions, one at 4.7 MeV and one at 4.9 MeV, the polarized photon beam of the High Intensity {gamma}-ray Source (HI{gamma}S) at Duke University was used. The experiment at HI{gamma}S revealed the existence of a photo-excited state of {sup 205}Tl at an excitation energy of 4.971 MeV that exhibits a transition to the first excited state at 203 keV.

  17. Ultraviolet radiation dosimetry using CaF2 TL phosphors- state of the art

    International Nuclear Information System (INIS)

    Nagpal, J.S.

    2001-01-01

    Photoluminescence (PL), optical absorption (OA) and thermoluminescence (TL) of undoped and Dy, Tb- and Eu activated CaF 2 TL phosphors has been re-investigated after heat treatment (600-1100 degC) in air. The study confirmed the earlier observed increase in intrinsic UV response of CaF 2 : Dy 3+ after 900 degC heat treatment. Enhancement in UV response was also observed in undoped CaF 2 thus indicating the base matrix related phenomenon. However, the enhancement observed in UV sensitivity and the optimum treatment temperature for high UV sensitivity is different for different activators. It is activator specific and needs further probing. UV response of undoped CaF 2 monotonically increases as the treatment temperature (in air) is increased from 600 degC to 1100 degC. Similar increase is observed in case of CaF 2 : Tb 3+ also. However, CaF 2 : Dy 3+ and CaF 2 :Eu 2+ follow a different pattern. Heat treatment in air increases UV response of CaF 2 : Dy 3+ up to 900 degC, and a decrease is observed at higher temperatures. UV response of CaF 2 : Eu 2+ is maximum for 600 degC treatment in air and decreases thereafter. TL response of CaF 2 : Tb and CaF 2 : Eu 2+ phosphors to UV is high, can be employed over the range 10 -2 - 2 mJ.cm -2 and is rate independent for 250±10 nm UV. (author)

  18. Transfer Efficiency of Bacteria and Viruses from Porous and Nonporous Fomites to Fingers under Different Relative Humidity Conditions

    Science.gov (United States)

    Gerba, Charles P.; Tamimi, Akrum H.; Kitajima, Masaaki; Maxwell, Sheri L.; Rose, Joan B.

    2013-01-01

    Fomites can serve as routes of transmission for both enteric and respiratory pathogens. The present study examined the effect of low and high relative humidity on fomite-to-finger transfer efficiency of five model organisms from several common inanimate surfaces (fomites). Nine fomites representing porous and nonporous surfaces of different compositions were studied. Escherichia coli, Staphylococcus aureus, Bacillus thuringiensis, MS2 coliphage, and poliovirus 1 were placed on fomites in 10-μl drops and allowed to dry for 30 min under low (15% to 32%) or high (40% to 65%) relative humidity. Fomite-to-finger transfers were performed using 1.0 kg/cm2 of pressure for 10 s. Transfer efficiencies were greater under high relative humidity for both porous and nonporous surfaces. Most organisms on average had greater transfer efficiencies under high relative humidity than under low relative humidity. Nonporous surfaces had a greater transfer efficiency (up to 57%) than porous surfaces (humidity, as well as under high relative humidity (nonporous, up to 79.5%; porous, <13.4%). Transfer efficiency also varied with fomite material and organism type. The data generated can be used in quantitative microbial risk assessment models to assess the risk of infection from fomite-transmitted human pathogens and the relative levels of exposure to different types of fomites and microorganisms. PMID:23851098

  19. Capture Efficiency of Cooking-Related Fine and Ultrafine Particles by Residential Exhaust Hoods

    Energy Technology Data Exchange (ETDEWEB)

    Lunden, Melissa M.; Delp, William W.

    2014-06-05

    Effective exhaust hoods can mitigate the indoor air quality impacts of pollutant emissions from residential cooking. This study reports capture efficiencies (CE) measured for cooking generated particles for scripted cooking procedures in a 121-m3 chamber with kitchenette. CEs also were measured for burner produced CO2 during cooking and separately for pots and pans containing water. The study used four exhaust hoods previously tested by Delp and Singer (Environ. Sci. Technol., 2012, 46, 6167-6173). For pan-frying a hamburger over medium heat on the back burner, CEs for particles were similar to those for burner produced CO2 and mostly above 80percent. For stir-frying green beans in a wok (high heat, front burner), CEs for burner CO2 during cooking varied by hood and airflow: CEs were 34-38percent for low (51?68 L s-1) and 54?72percent for high (109?138 L s-1) settings. CEs for 0.3?2.0 ?m particles during front burner stir-frying were 3?11percent on low and 16?70percent on high settings. Results indicate that CEs measured for burner CO2 are not predictive of CEs of cooking-generated particles under all conditions, but they may be suitable to identify devices with CEs above 80percent both for burner combustion products and for cooking-related particles.

  20. A bootstrap based analysis pipeline for efficient classification of phylogenetically related animal miRNAs

    Directory of Open Access Journals (Sweden)

    Gu Xun

    2007-03-01

    Full Text Available Abstract Background Phylogenetically related miRNAs (miRNA families convey important information of the function and evolution of miRNAs. Due to the special sequence features of miRNAs, pair-wise sequence identity between miRNA precursors alone is often inadequate for unequivocally judging the phylogenetic relationships between miRNAs. Most of the current methods for miRNA classification rely heavily on manual inspection and lack measurements of the reliability of the results. Results In this study, we designed an analysis pipeline (the Phylogeny-Bootstrap-Cluster (PBC pipeline to identify miRNA families based on branch stability in the bootstrap trees derived from overlapping genome-wide miRNA sequence sets. We tested the PBC analysis pipeline with the miRNAs from six animal species, H. sapiens, M. musculus, G. gallus, D. rerio, D. melanogaster, and C. elegans. The resulting classification was compared with the miRNA families defined in miRBase. The two classifications were largely consistent. Conclusion The PBC analysis pipeline is an efficient method for classifying large numbers of heterogeneous miRNA sequences. It requires minimum human involvement and provides measurements of the reliability of the classification results.

  1. Effects of the TAT peptide orientation and relative location on the protein transduction efficiency.

    Science.gov (United States)

    Guo, Qingguo; Zhao, Guojie; Hao, Fengjin; Guan, Yifu

    2012-05-01

    To understand the protein transduction domain (PTD)-mediated protein transduction behavior and to explore its potential in delivering biopharmaceutic drugs, we prepared four TAT-EGFP conjugates: TAT(+)-EGFP, TAT(-)-EGFP, EGFP-TAT(+) and EGFP-TAT(-), where TAT(+) and TAT(-) represent the original and the reversed TAT sequence, respectively. These four TAT-EGFP conjugates were incubated with HeLa and PC12 cells for in vitro study as well as injected intraperitoneally to mice for in vivo study. Flow cytometric results showed that four TAT-EGFP conjugates were able to traverse HeLa and PC12 cells with almost equal transduction efficiency. The in vivo study showed that the TAT-EGFP conjugates could be delivered into different organs of mice with different transduction capabilities. Bioinformatic analyses and CD spectroscopic data revealed that the TAT peptide has no defined secondary structure, and conjugating the TAT peptide to the EGFP cargo protein would not alter the native structure and the function of the EGFP protein. These results conclude that the sequence orientation, the spatial structure, and the relative location of the TAT peptide have much less effect on the TAT-mediated protein transduction. Thus, the TAT-fused conjugates could be constructed in more convenient and flexible formats for a wide range of biopharmaceutical applications. © 2011 John Wiley & Sons A/S.

  2. Capture efficiency of cooking-related fine and ultrafine particles by residential exhaust hoods.

    Science.gov (United States)

    Lunden, M M; Delp, W W; Singer, B C

    2015-02-01

    Effective exhaust hoods can mitigate the indoor air quality impacts of pollutant emissions from residential cooking. This study reports capture efficiencies (CE) measured for cooking-generated particles for scripted cooking procedures in a 121-m3 chamber with kitchenette. CEs also were measured for burner produced CO2 during cooking and separately for pots and pans containing water. The study used four exhaust hoods previously tested by Delp and Singer (Environ. Sci. Technol., 2012, 46, 6167-6173). For pan-frying a hamburger over medium heat on the back burner, CEs for particles were similar to those for burner produced CO2 and mostly above 80%. For stir-frying green beans in a wok (high heat, front burner), CEs for burner CO2 during cooking varied by hood and airflow: CEs were 34-38% for low (51-68 l/s) and 54-72% for high (109-138 l/s) settings. CEs for 0.3-2.0 μm particles during front burner stir-frying were 3-11% on low and 16-70% on high settings. Results indicate that CEs measured for burner CO2 are not predictive of CEs of cooking-generated particles under all conditions, but they may be suitable to identify devices with CEs above 80% both for burner combustion products and for cooking-related particles. Published 2014. This article is a U.S. Government work and is in the public domain in the USA.

  3. Age-related changes of frontal-midline theta is predictive of efficient memory maintenance.

    Science.gov (United States)

    Kardos, Z; Tóth, B; Boha, R; File, B; Molnár, M

    2014-07-25

    Frontal areas are thought to be the coordinators of working memory processes by controlling other brain areas reflected by oscillatory activities like frontal-midline theta (4-7 Hz). With aging substantial changes can be observed in the frontal brain areas, presumably leading to age-associated changes in cortical correlates of cognitive functioning. The present study aimed to test whether altered frontal-midline theta dynamics during working memory maintenance may underlie the capacity deficits observed in older adults. 33-channel EEG was recorded in young (18-26 years, N=20) and old (60-71 years, N=16) adults during the retention period of a visual delayed match-to-sample task, in which they had to maintain arrays of 3 or 5 colored squares. An additional visual odd-ball task was used to be able to measure the electrophysiological indices of sustained attentional processes. Old participants showed reduced frontal theta activity during both tasks compared to the young group. In the young memory maintenance-related frontal-midline theta activity was shown to be sensitive both to the increased memory demands and to efficient subsequent memory performance, whereas the old adults showed no such task-related difference in the frontal theta activity. The decrease of frontal-midline theta activity in the old group indicates that cerebral aging may alter the cortical circuitries of theta dynamics, thereby leading to age-associated decline of working memory maintenance function. Copyright © 2014 IBRO. Published by Elsevier Ltd. All rights reserved.

  4. Activation analysis of thallium by /sup 203/Tl(n,2n)/sup 202/Tl reaction in nuclear reactors

    Energy Technology Data Exchange (ETDEWEB)

    Cohen, I M; Resnizky, S M; Baro, G B [Comision Nacional de Energia Atomica, Buenos Aires (Argentina). Gerencia de Radioisotopos y Radiaciones

    1982-01-01

    Two techniques are described for neutron activation analysis of thallium in biological and geological materials, based on /sup 203/Tl(n,2n)/sup 202/Tl reaction in nuclear reactors. Co-precipitation with bismuth sulphide is used as a pre-concentration method of thallium in urine samples, and post-irradiation chemical separation is also performed. The detection limit is 0.5 ..mu..g/l, for 100 ml urine samples. For thallium determination in blendes a radiochemical separation is carried out after the irradiation. An extension of this technique is presented for glass and silicate rocks. Results for seven blende samples from different places of Argentina are shown. Analysis of two reference materials, the 614 glass from the National Bureau of Standards and the granodiorite GSP-1 from the U.S. Geological Survey were also performed. The results are in very good agreement with the certified or estimated values.

  5. Exploring the thermoelectric and magnetic properties of uranium selenides: Tl2Ag2USe4 and Tl3Cu4USe6

    International Nuclear Information System (INIS)

    Azam, Sikander; Khan, Saleem Ayaz; Din, Haleem Ud; Khenata, Rabah; Goumri-Said, Souraya

    2016-01-01

    The electronic, magnetic and thermoelectric properties of Tl 2 Ag 2 USe 4 and Tl 3 Cu 4 USe 6 compounds were investigated using the full potential linear augmented plane wave (FP-LAPW) method based on the density functional theory (DFT). The exchange correlation was treated with the generalized gradient approximation plus optimized effective Hubbard parameter and spin–orbit coupling (GGA+U+SOC). The present uranium selenides show narrow direct energy band gap values of 0.7 and 0.875 eV for Tl 2 Ag 2 USe 4 and Tl 3 Cu 4 USe 6 respectively. For both selenides U-d/f states are responsible for electrical transport properties. Uranium atoms were the most contributors in the magnetic moment compared to other atoms and show ferromagnetic nature. The spin density isosurfaces show the polarization of neighboring atoms of Uranium, such as silver/copper and selenium. Thermoelectric calculations reveal that Tl 3 Cu 4 USe 6 is more suitable for thermoelectric device applications than Tl 2 Ag 2 USe 4 . - Highlights: • Electronic, magnetic and thermoelectric properties of uranium selenides are investigated with DFT. • They show a narrow direct energy band gap of 0.7 and 0.875 eV. • U-d/f states are responsible for electrical transport properties. • Tl 3 Cu 4 USe 6 is more suitable for thermoelectric device applications than Tl 2 Ag 2 USe 4 .

  6. Impact of intense x-ray pulses on a NaI(Tl)-based gamma camera

    Science.gov (United States)

    Koppert, W. J. C.; van der Velden, S.; Steenbergen, J. H. L.; de Jong, H. W. A. M.

    2018-03-01

    In SPECT/CT systems x-ray and γ-ray imaging is performed sequentially. Simultaneous acquisition may have advantages, for instance in interventional settings. However, this may expose a gamma camera to relatively high x-ray doses and deteriorate its functioning. We studied the NaI(Tl) response to x-ray pulses with a photodiode, PMT and gamma camera, respectively. First, we exposed a NaI(Tl)-photodiode assembly to x-ray pulses to investigate potential crystal afterglow. Next, we exposed a NaI(Tl)-PMT assembly to 10 ms LED pulses (mimicking x-ray pulses) and measured the response to flashing LED probe-pulses (mimicking γ-pulses). We then exposed the assembly to x-ray pulses, with detector entrance doses of up to 9 nGy/pulse, and analysed the response for γ-pulse variations. Finally, we studied the response of a Siemens Diacam gamma camera to γ-rays while exposed to x-ray pulses. X-ray exposure of the crystal, read out with a photodiode, revealed 15% afterglow fraction after 3 ms. The NaI(Tl)-PMT assembly showed disturbances up to 10 ms after 10 ms LED exposure. After x-ray exposure however, responses showed elevated baselines, with 60 ms decay-time. Both for x-ray and LED exposure and after baseline subtraction, probe-pulse analysis revealed disturbed pulse height measurements shortly after exposure. X-ray exposure of the Diacam corroborated the elementary experiments. Up to 50 ms after an x-ray pulse, no events are registered, followed by apparent energy elevations up to 100 ms after exposure. Limiting the dose to 0.02 nGy/pulse prevents detrimental effects. Conventional gamma cameras exhibit substantial dead-time and mis-registration of photon energies up to 100 ms after intense x-ray pulses. This is due PMT limitations and due to afterglow in the crystal. Using PMTs with modified circuitry, we show that deteriorative afterglow effects can be reduced without noticeable effects on the PMT performance, up to x-ray pulse doses of 1 nGy.

  7. TL, OSL and C-14 dating results of the sediments and bricks from mummified nuns' grave

    Directory of Open Access Journals (Sweden)

    Diego R.G. Tudela

    2012-06-01

    Full Text Available This paper presents the results of TL and OSL dating of soil and fragments of bricks from a grave, which was occupied by two mummified nuns, found at "Luz" Monastery, located in the state of São Paulo, Brazil. The TL and OSL ages were compared to C-14 dating ones obtained from bone collagens of the mummies. The majority of the ages is related to the eighteenth century. The gamma-ray spectroscopy was used to evaluate natural radioisotope concentrations in the samples, and by using these concentrations the annual dose rates, from 3.0 to 5.3 Gy/kyr, were obtained. Neutron activation analysis was performed and the radioisotope contents results are in agreement with those obtained by gamma-ray spectroscopy. The contents of U, Th and Ce elements were higher than those found in usual sediments.Este artigo apresenta os resultados de datação por TL e OSL de solos, e fragmentos de tijolos de um túmulo, que foi ocupado por duas freiras mumificadas encontradas no Mosteiro da "Luz", localizado no Estado de São Paulo, Brasil. As idades encontradas por TL e OSL foram comparadas às obtidas a partir de C-14 dos colágenos contidos em amostras de osso das múmias. A maioria das idades obtidas são do século XVIII. A espectroscopia de radiação-gama foi utilizada para avaliar concentrações de radioisótopos naturais nas amostras e para calcular as taxas de dose anual que resultaram em 3,0 a 5,3 Gy/kano. As concentrações radioativas são próximas daquelas obtidas através de Análise por Ativação de Nêutrons. Os conteúdos de elementos U, Th e Ce são superiores aos encontrados na maioria dos sedimentos.

  8. Effect of particle size in the TL response of natural quartz sensitized by high dose of gamma radiation and heat-treatments

    Directory of Open Access Journals (Sweden)

    Álvaro Barbosa de Carvalho Jr

    2010-06-01

    Full Text Available This work investigates the effect of particle size in the thermoluminescence (TL response of a quartz crystal that was initially crushed and classified into ten size fractions between 38 μm and 5 mm. Aliquots of each size fraction were sensitized with a dose of 25 kGy of γ rays and heat-treatments at 400 °C. TL glow curves of sensitized and non-sensitized samples were recorded as a function of different test-doses of γ rays. For the non-sensitized samples, the TL peak near 325 °C increases with the decrease in particle size. In the case of sensitized samples, a strong TL peak near 300 °C increases with the increase in particle size up to mean grain size equal to 304 μm. Above 304 μm, an abrupt reduction in the TL intensity is noticed for the sensitized peak. These effects are discussed in relation to the specific surface area of quartz particles and the intensity of the electron paramagnetic resonance signal of the E'1 center induced by the sensitization process.

  9. Thermal analysis of chalcogenide glasses of the system (As/sub/2Se/sub/3)/sub/(1-x):(Tl/sub/2Se)/sub/x

    International Nuclear Information System (INIS)

    Majid, C.A.

    1987-01-01

    In this paper differential thermal analysis (DTA) measurements of chalcogenide glasses of the system (As/sub/2Se/sub/3)/sub/(1-x): (Tl/sub/2Se)/sub/x, with x=0, 0.125, 0.25 and 0.50 are reported. The glass-forming tendencies of these materials have been calculated. The glass-forming tendency of As/sub/2Se/sub/3 has been found to be the highest among the member glasses of this family of chalcogenides. It was found that the glass-forming tendency of As/sub/2Se/sub/3 decreasing gradually at the Tl/sub/2/Se concentration increases. Tl/sub/2Se additions lower the glass transition temperature T/sub/q and the area under the endothermic peak for glass transition temperature, suggesting a tendency for relatively weaker bonding and hence less stability of Tl-rich glass compositions. These studies show that Tl/sub/2Se concentrations result in glasses with progressively higher crystallization tendencies. (author)

  10. Gamma-radiation-induced change in the activation energy of TL traps in LiRbSO[sub 4]:Tl

    Energy Technology Data Exchange (ETDEWEB)

    Kassem, M.E.; El-Kolaly, M.A.; Al-Houty, L.I. (Qatar Univ., Doha (Qatar). Dept. of Physics)

    1994-06-01

    Thermoluminescence (TL) measurements were carried out for pure and doped LiRbSO[sub 4], with different concentrations of thallium (Tl). The glow-curve range of measurement is between room temperature up to 300[sup o]C. The radiation absorbed dose is in the range 56-3.2 x 10[sup 5] Gy. The results show that both pure and doped samples have glow peak temperatures that are dose dependent, and vary between 70-80[sup o]C and 140-170[sup o]C for pure and doped samples respectively. Doped samples display double peaks that increase with dopant concentration up to about 0.7% wt. The second peak which occurs at high temperature increases linearly with dose up to 4500 Gy. From the results it is proposed that LiRbSO[sub 4] doped with 0.7% Tl can be used for dosimetric purposes in this range. The activation energies of structural transitions are estimated and the results are discussed on the basis of radiation-induced stable dipoles in the random field system. (Author).

  11. Sensitivity of LDEF foil analyses using ultra-low background germanium vs. large NaI(Tl) multidimensional spectrometers

    International Nuclear Information System (INIS)

    Reeves, J.H.; Arthur, R.J.; Brodzinski, R.L.

    1992-06-01

    Cobalt foils and stainless steel samples were analyzed for induced 6O Co activity with both an ultra-low background germanium gamma-ray spectrometer and with a large NaI(Tl) multidimensional spectrometer, both of which use electronic anticoincidence shielding to reduce background counts resulting from cosmic rays. Aluminum samples were analyzed for 22 Na. The results, in addition to the relative sensitivities and precisions afforded by the two methods, are presented

  12. Tl-201 and Tc-99m-DTPA neuro-SPECT in cerebral radiation necrosis

    International Nuclear Information System (INIS)

    Cleto, E.M. Jr.; Holmes, R.A.; Gumerlock, M.K.; Cabeen, M.; Logan, K.W.; Hoffman, T.J.

    1992-01-01

    The results in 3 cases of radiation necrosis demonstrate that by using both radionuclides Tl-201 and Tc-99m-DTPA, one can provide a semi-quantitative method to differentiate recurrent tumor from radiation necrosis. Focally increased cerebral Tl-201 activity in irradiated brain tumor patients is not specific for tumor recurrence, but when used in combination with DTPA, one is able to estimate the amount of Tl-201 activity resulting from increased blood-brain barrier permeability. If the average Tl-201 index is less than the average Tc-99m-DTPA index it suggests that the increased Tl-201 activity results primarily from blood-brain barrier breakdown. Tc-99m-DTPA SPECT, in addition to Tl-201 SPECT, or serial Tl-201 SPECT imaging may increase the accuracy of brain scintigraphy in differentiating radiation necrosis from tumor recurrence. To verify these preliminary findings, we are in the process of analyzing additional SPECT data on 9 more patients with malignant brain tumors. Using a slightly different method of quantifying Tl- 201/Tc-99m-DTPA ratios (computing the ratio of intralesional Tl-201 or Tc-99m-DTPA activity compared to adjacent scalp activity), patients with tumor recurrence have higher Tl-201/Tc-99m-DTPA ratios compared to those with radiation necrosis (verbal communication with Dr. Mary K. Gumerlock). (orig.) [de

  13. Comparisons of 131I, 201Tl and 99mTc activity measurements in activimeters

    International Nuclear Information System (INIS)

    Oropesa Verdecia, Pilar; Hernandez Rivero, Aerulio T.; Serra Aguila, Rolando A.; Martinez Herrera, Ernesto; Varela Corona, Consuelo

    2003-01-01

    The correct administration to a patient of the a priori established activity of the radiopharmaceutical is an important factor to ensure the confidence in the diagnosis or the therapy efficiency, keeping at the same time the human exposure as low as possible. National comparisons for the 131I, 201Tl and 99mTc activity measurements in activimeters have been organized for the first time with the aim of obtaining information about the quality of the administration of radiopharmaceuticals. In the comparison run participated ten Cuban Nuclear Medicine Departments and the laboratories involved in the production of that kind of compounds. The comparison results, shown in this paper, have facilitated the identification of the problems and to initiate preventive actions. Furthermore, these results reflect the need of establishing Quality Systems in Nuclear Medicine in Cuba

  14. Monitoring of garbage with a 5x5NaI (Tl) detector

    International Nuclear Information System (INIS)

    Cortes P, A.; Becerril V, A.; Angeles C, A.

    1991-12-01

    So far in that is carried out the first reload of nuclear fuel in the LVC, the monitoring of garbage has been carried out using monitors trade mark Eberline model RM 14. The procedure consists in manually monitoring each object and to separate of the considered 'clean' garbage the objects considered as contaminated, which register greater or equal counts to 100 cpm. This way to process was adequate under normal operation conditions, but not in the operation rhythm that implies a bigger maintenance since the time required for monitoring from 5 to 10 kg. of garbage is of the order of 0.5 hours and the production rhythm of this it ends up being a lot but high. Due to this necessity it was thought about the problem of looking by a more efficient monitoring method. In this work a method that uses a detector of NaI (Tl) of 5 x 5 inches is discussed. (Author)

  15. Electronic structure of TlBa2CaCu2O7-δ

    Science.gov (United States)

    Vasquez, R. P.; Novikov, D. L.; Freeman, A. J.; Siegal, M. P.

    1997-06-01

    The core levels of TlBa2CaCu2O7-δ (Tl-1212) epitaxial films have been measured with x-ray photoelectron spectroscopy (XPS). The valence electronic structure has been determined using the full-potential linear muffin-tin-orbital band-structure method and measured with XPS. The calculations show that a van Hove singularity (VHS) lies above the Fermi level (EF) for the stoichiometric compound (δ=0), while for 50% oxygen vacancies in the Tl-O layer (δ=0.5) EF is in close proximity to the VHS. Samples annealed in nitrogen (to reduce the hole overdoping by the removal of oxygen) exhibit higher core-level binding energies and a higher Tc, consistent with a shift of EF closer to the VHS. Comparisons are made to the core levels and valence bands of Tl2Ba2CaCu2O8+δ (Tl-2212) and HgBa2CaCu2O6+δ (Hg-1212). The similarity of the Cu 2p3/2 spectra for Tl-1212 and Tl-2212 indicates that the number of Tl-O layers has little effect on the Cu-O bonding. However, the Tl-1212 and Hg-1212 Cu 2p3/2 signals exhibit differences which suggest that the replacement of Tl3+ with Hg2+ results in a decrease in the O 2p-->Cu 3d charge-transfer energy and differences in the probabilities of planar vs apical oxygen charge transfer and/or Zhang-Rice singlet-state formation. Differences between the Tl-1212 and the Tl-2212 and Hg-1212 measured valence bands are consistent with the calculated Cu 3d and (Tl,Hg) 6s/5d partial densities of states.

  16. Electronic structure of TlBa2CaCu2O7-δ

    International Nuclear Information System (INIS)

    Vasquez, R.P.; Novikov, D.L.; Freeman, A.J.; Siegal, M.P.

    1997-01-01

    The core levels of TlBa 2 CaCu 2 O 7-δ (Tl-1212) epitaxial films have been measured with x-ray photoelectron spectroscopy (XPS). The valence electronic structure has been determined using the full-potential linear muffin-tin-orbital band-structure method and measured with XPS. The calculations show that a van Hove singularity (VHS) lies above the Fermi level (E F ) for the stoichiometric compound (δ=0), while for 50% oxygen vacancies in the Tl-O layer (δ=0.5) E F is in close proximity to the VHS. Samples annealed in nitrogen (to reduce the hole overdoping by the removal of oxygen) exhibit higher core-level binding energies and a higher T c , consistent with a shift of E F closer to the VHS. Comparisons are made to the core levels and valence bands of Tl 2 Ba 2 CaCu 2 O 8+δ (Tl-2212) and HgBa 2 CaCu 2 O 6+δ (Hg-1212). The similarity of the Cu 2p 3/2 spectra for Tl-1212 and Tl-2212 indicates that the number of Tl-O layers has little effect on the Cu-O bonding. However, the Tl-1212 and Hg-1212 Cu 2p 3/2 signals exhibit differences which suggest that the replacement of Tl 3+ with Hg 2+ results in a decrease in the O 2p→Cu 3d charge-transfer energy and differences in the probabilities of planar vs apical oxygen charge transfer and/or Zhang-Rice singlet-state formation. Differences between the Tl-1212 and the Tl-2212 and Hg-1212 measured valence bands are consistent with the calculated Cu 3d and (Tl,Hg) 6s/5d partial densities of states. copyright 1997 The American Physical Society

  17. Influence of deep traps in the Tl response of ZrO{sub 2} + PTFE; Influencia de las trampas profundas en la respuesta Tl de ZrO{sub 2} + PTFE

    Energy Technology Data Exchange (ETDEWEB)

    Rivera M, T.; Azorin N, J.; Falcony G, C.; Martinez S, E.; Garcia H, M. [Universidad Autonoma Metropolitana-Iztapalapa, 09340 Mexico D.F. (Mexico)

    2000-07-01

    In this work are presented the results from investigating the processes related with the defects produced by ionizing radiation in ZrO{sub 2}. It is established an hypothesis which pretends to explain the phenomena that implicates the manifestation of Tl peaks in the brightness curve due to electron removal from the surface traps to the deep traps, through the thermo-transference process, where the excitonic process correspond to the F centers. During the experimental process it was observed this effect through the peaks running in Tl curve. These peaks are presented at 220 and 360 Centigrade for the material without any previous thermal treatment; while that in the samples thermally treated at 100 Centigrade during 1 minute it is observed a slipping in the first peak from 220 to 280 Centigrade, while the second stays in 360 Centigrade. (Author)

  18. Surface defect free growth of a spin dimer TlCuCl{sub 3} compound crystals and investigations on its optical and magnetic properties

    Energy Technology Data Exchange (ETDEWEB)

    Ryu, Gihun, E-mail: G.Ryu@fkf.mpg.de [Max Planck Institute for Solid State Research, Heisenbergstraße 1, 70569 Stuttgart (Germany); Son, Kwanghyo [Max Planck Institute for Intelligent Systems, Heisenbergstraße 3, 70569 Stuttgart (Germany)

    2016-05-15

    A defect-free high quality single crystal of spin dimer TlCuCl{sub 3} compound is firstly synthesized at the optimal growth temperature using the vertical Bridgman method. In this study, we clearly found that the cupric chloride is easily decomposed into the Cl{sup −} deficient composition at ≥470 °C. The Cl{sup −}- related gas phase at the high temperature region also always gives rise to a pinhole-like surface defect at the surface of crystal. Therefore, we clearly verified an exotic anisotropic magnetic behavior (anisotropic ratio of M{sub b}/M{sub (201)} at 2 K, 7 T=10) using the defect-free TlCuCl{sub 3} crystals in this three-dimensional spin dimer TlCuCl{sub 3} compound, relatively stronger magnetic ordering in the H//b than that of H//(201) direction at above the transition magnetic field. - Graphical abstract: A single crystal of spin dimer TlCuCl{sub 3} compound with a defect free is successfully synthesized on the basis of TG/DTA result. We newly found that this cupric chloride compound is easily decomposed into the Cl{sup −} deficient composition at ≥470 °C and Cl{sup −} related gas phases also give rise to the defects like a pinhole on the surface of TlCuCl{sub 3} crystal. Using the crystals with a surface defect free, we also clearly verified the crystal structure of spin dimer TlCuCl{sub 3} compound.

  19. Carotenoid coloration is related to fat digestion efficiency in a wild bird

    Science.gov (United States)

    Madonia, Christina; Hutton, Pierce; Giraudeau, Mathieu; Sepp, Tuul

    2017-12-01

    Some of the most spectacular visual signals found in the animal kingdom are based on dietarily derived carotenoid pigments (which cannot be produced de novo), with a general assumption that carotenoids are limited resources for wild organisms, causing trade-offs in allocation of carotenoids to different physiological functions and ornamentation. This resource trade-off view has been recently questioned, since the efficiency of carotenoid processing may relax the trade-off between allocation toward condition or ornamentation. This hypothesis has so far received little exploratory support, since studies of digestive efficiency of wild animals are limited due to methodological difficulties. Recently, a method for quantifying the percentage of fat in fecal samples to measure digestive efficiency has been developed in birds. Here, we use this method to test if the intensity of the carotenoid-based coloration predicts digestive efficiency in a wild bird, the house finch ( Haemorhous mexicanus). The redness of carotenoid feather coloration (hue) positively predicted digestion efficiency, with redder birds being more efficient at absorbing fats from seeds. We show for the first time in a wild species that digestive efficiency predicts ornamental coloration. Though not conclusive due to the correlative nature of our study, these results strongly suggest that fat extraction might be a crucial but overlooked process behind many ornamental traits.

  20. In vivo evaluation of the effect of stimulus distribution on FIR statistical efficiency in event-related fMRI.

    Science.gov (United States)

    Jansma, J Martijn; de Zwart, Jacco A; van Gelderen, Peter; Duyn, Jeff H; Drevets, Wayne C; Furey, Maura L

    2013-05-15

    Technical developments in MRI have improved signal to noise, allowing use of analysis methods such as Finite impulse response (FIR) of rapid event related functional MRI (er-fMRI). FIR is one of the most informative analysis methods as it determines onset and full shape of the hemodynamic response function (HRF) without any a priori assumptions. FIR is however vulnerable to multicollinearity, which is directly related to the distribution of stimuli over time. Efficiency can be optimized by simplifying a design, and restricting stimuli distribution to specific sequences, while more design flexibility necessarily reduces efficiency. However, the actual effect of efficiency on fMRI results has never been tested in vivo. Thus, it is currently difficult to make an informed choice between protocol flexibility and statistical efficiency. The main goal of this study was to assign concrete fMRI signal to noise values to the abstract scale of FIR statistical efficiency. Ten subjects repeated a perception task with five random and m-sequence based protocol, with varying but, according to literature, acceptable levels of multicollinearity. Results indicated substantial differences in signal standard deviation, while the level was a function of multicollinearity. Experiment protocols varied up to 55.4% in standard deviation. Results confirm that quality of fMRI in an FIR analysis can significantly and substantially vary with statistical efficiency. Our in vivo measurements can be used to aid in making an informed decision between freedom in protocol design and statistical efficiency. Published by Elsevier B.V.

  1. Cell nuclei attributed relational graphs for efficient representation and classification of gastric cancer in digital histopathology

    Science.gov (United States)

    Sharma, Harshita; Zerbe, Norman; Heim, Daniel; Wienert, Stephan; Lohmann, Sebastian; Hellwich, Olaf; Hufnagl, Peter

    2016-03-01

    This paper describes a novel graph-based method for efficient representation and subsequent classification in histological whole slide images of gastric cancer. Her2/neu immunohistochemically stained and haematoxylin and eosin stained histological sections of gastric carcinoma are digitized. Immunohistochemical staining is used in practice by pathologists to determine extent of malignancy, however, it is laborious to visually discriminate the corresponding malignancy levels in the more commonly used haematoxylin and eosin stain, and this study attempts to solve this problem using a computer-based method. Cell nuclei are first isolated at high magnification using an automatic cell nuclei segmentation strategy, followed by construction of cell nuclei attributed relational graphs of the tissue regions. These graphs represent tissue architecture comprehensively, as they contain information about cell nuclei morphology as vertex attributes, along with knowledge of neighborhood in the form of edge linking and edge attributes. Global graph characteristics are derived and ensemble learning is used to discriminate between three types of malignancy levels, namely, non-tumor, Her2/neu positive tumor and Her2/neu negative tumor. Performance is compared with state of the art methods including four texture feature groups (Haralick, Gabor, Local Binary Patterns and Varma Zisserman features), color and intensity features, and Voronoi diagram and Delaunay triangulation. Texture, color and intensity information is also combined with graph-based knowledge, followed by correlation analysis. Quantitative assessment is performed using two cross validation strategies. On investigating the experimental results, it can be concluded that the proposed method provides a promising way for computer-based analysis of histopathological images of gastric cancer.

  2. Method of relative comparison of the thermohydraulic efficiency of heat exchange intensification in channels of heat-exchange surfaces

    International Nuclear Information System (INIS)

    Dubrovskij, E.V.; Vasil'ev, V.Ya.

    2002-01-01

    One introduces a technique to compare relatively thermohydraulic efficiency of heat transfer intensification in channels of heat exchange surfaces of any design types. It is shown that one should compare thermohydraulic efficiency of heat exchange intensification as to the thermal power of heat exchangers and pressure losses in channels with turbulators and in polished channels of heat exchange surfaces on the basis of dimensions of heat exchangers, their heat exchange surfaces and at similar (as to Re numbers) modes of coolant flow [ru

  3. Natural Gas and CO2 Price Variation: Impact on the Relative Cost-Efficiency of LNG and Pipelines

    OpenAIRE

    Øverland, Indra; Ulvestad, Marte

    2012-01-01

    This article develops a formal model for comparing the cost structure of the two main transport options for natural gas: liquefied natural gas (LNG) and pipelines. In particular, it evaluates how variations in the prices of natural gas and greenhouse gas emissions affect the relative cost-efficiency of these two options. Natural gas is often promoted as the most environmentally friendly of all fossil fuels, and LNG as a modern and efficient way of transporting it. Some research has been carri...

  4. Measuring naturally occurring uranium in soil and minerals by analysing the 352 keV gamma-ray peak of 214Pb using a NaI(Tl)-detector

    International Nuclear Information System (INIS)

    Bezuidenhout, J.

    2013-01-01

    This article investigates the prospect of utilising the 351.9 keV gamma-ray of 214 Pb when determining the concentration of uranium. Soil samples were collected from various locations around South Africa and laboratory gamma ray spectra for each were obtained by means of a NaI(Tl)-detector (7.62×7.62 cm 2 ). The potassium, uranium and thorium concentrations where extracted by analysing gamma ray peaks that are associated with these radionuclides. Two separate uranium concentrations were extracted; one by means of the 214 Pb decay and the other one by means of the 214 Bi decay. These uranium concentrations were compared in terms of accuracies and detection limits. - Highlights: • Investigated a method to improve uranium concentrations measurements. • Expansion on an existing method that analyses naturally occurring radionuclides. • Utilise pill containers opposed to Marrinelli beakers. • Possible application to in situ measurements. • The method utilise NaI(Tl)-detectors with relative high efficiency

  5. TL, OSL and C-14 dating results of the sediments and bricks from mummified nuns' grave

    Energy Technology Data Exchange (ETDEWEB)

    Tudela, Diego R.G.; Tatumi, Sonia H.; Yee, Marcio; Brito, Silvio L.M., E-mail: tatumi@fatecsp.br [Faculdades de Tecnologia de Sao Paulo (FATECs/CEETEPS/UNESP), Sao Paulo, SP (Brazil). Centro Estadual de Educacao Tecnologica Paula Souza; Morais, Jose L.; Morais, Daisy de; Piedade, Silvia C. [Universidade de Sao Paulo (USP), SP (Brazil). Museu de Arqueologia e Etnologia; Munita, Casimiro S.P.; Hazenfratz, Roberto [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2012-06-15

    This paper presents the results of TL and OSL dating of soil and fragments of bricks from a grave, which was occupied by two mummified nuns, found at 'Luz' Monastery, located in the state of Sao Paulo, Brazil. The TL and OSL ages were compared to C-14 dating ones obtained from bone collagens of the mummies. The majority of the ages is related to the eighteenth century. The gamma-ray spectroscopy was used to evaluate natural radioisotope concentrations in the samples, and by using these concentrations the annual dose rates, from 3.0 to 5.3 Gy/kyr, were obtained. Neutron activation analysis was performed and the radioisotope contents results are in agreement with those obtained by gamma-ray spectroscopy. The contents of U, Th and Ce elements were higher than those found in usual sediments. (author)

  6. Magnetic excitations and exchange interactions in the spin-gap system TlCuCl sub 3

    CERN Document Server

    Oosawa, A; Kato, T; Kakurai, K; Müller, M; Mikeska, H J

    2002-01-01

    The magnetic excitations from the gapped ground state in TlCuCl sub 3 have been investigated by means of inelastic neutron scattering experiments. The excitation data were collected along four different directions in the a sup * -c sup * plane. A well-defined single magnetic excitation mode was observed. The lowest excitation occurs at Q=(h,0,l) with integer h and odd l, as observed in KCuCl sub 3. The dispersion relations were analyzed by the cluster-series expansion up to the sixth order, so that the individual exchange interactions were evaluated. It was demonstrated that TlCuCl sub 3 is a strongly coupled spin-dimer system. (orig.)

  7. OSL, TL and IRSL emission spectra of sedimentary quartz and feldspar samples

    International Nuclear Information System (INIS)

    Lomax, Johanna; Mittelstraß, Dirk; Kreutzer, Sebastian; Fuchs, Markus

    2015-01-01

    This contribution presents a variety of different luminescence emission spectra from sedimentary feldspar and quartz samples under various stimulation modes. These are green stimulated quartz (OSL-) spectra, quartz TL spectra, feldspar IRSL and post-IR IRSL spectra. A focus was set at recording OSL and IRSL spectra at elevated stimulation temperatures such as routinely applied in luminescence dating. This was to test whether optical stimulation at elevated temperatures results in a shift of emission peaks. For OSL emissions of quartz, this has so far not been tested. In case of feldspar emissions, post-IR IRSL conditions, hence IRSL emissions at a low temperature, directly followed by high temperature post-IRSL emissions, are explicitly investigated. All spectra were recorded using a new system incorporated into a Lexsyg luminescence reader. Thus, this study, besides presenting new spectral data, also serves as a feasibility study for this new device. It is shown that (a) the new device is capable of automatically measuring different sorts of spectra, also at elevated temperatures, (b) known thermally and optically stimulated peak emissions of quartz and feldspar are confirmed, (c) obtained IRSL and OSL spectra indicate that there is no significant relation between peak emission and stimulation temperature. - Highlights: • We have measured OSL, IRSL and TL emission spectra of sedimentary quartz and feldspar samples. • Spectral analyses were performed at elevated stimulation temperatures. • Emission spectra show very little variation with stimulation temperatures.

  8. Evidence of global-scale As, Mo, Sb, and Tl atmospheric pollution in the antarctic snow.

    Science.gov (United States)

    Hong, Sungmin; Soyol-Erdene, Tseren-Ochir; Hwang, Hee Jin; Hong, Sang Bum; Hur, Soon Do; Motoyama, Hidaeki

    2012-11-06

    We report the first comprehensive and reliable time series for As, Mo, Sb, and Tl in the snowpack from Dome Fuji in the central East Antarctic Plateau. Our results show significant enrichment of these elements due to either anthropogenic activities or large volcanic eruptions during the past 50 years. With respect to the values reported from 1960 to 1964, we observed the maximum increases in crustal enrichment factors (EFs) for As (a factor of ~15), Mo (~4), Sb (~4), and Tl (~2) during the period between the 1970s and 1990s, reflecting the global dispersion of anthropogenic pollutants of these elements, even to the most remote areas on Earth. Such enrichments are likely related to emissions of trace elements from nonferrous metal smelting and fossil fuel combustion processes in South America, especially in Chile. A drastic decrease in the As concentration and its EF values was observed after the year 2000 in response to the introduction of environmental regulations in the 1990s to reduce As emissions from the copper industry, primarily in Chile. The observed decrease suggests that governmental regulations for pollution control are effective in reducing air pollution at both the regional and global level.

  9. Measuring thermo-luminescence efficiency of TLD-2000 detectors to different energy photons

    Energy Technology Data Exchange (ETDEWEB)

    Xie, Wei Min; Chen, Bao Wei; Han, Yi; Yang, Zhong Jian [China Institute for Radiation Protection, Taiyuan (China)

    2016-06-15

    As an important detecting device, TLD is a widely used in the radiation monitoring. It is essential for us to study the property of detecting element. The aim of this study is to calculate the thermo-luminescence efficiency of TL elements. A batch of thermo-luminescence elements were irradiated by the filtered X-ray beams of average energies in the range 40-200 kVp, 662 keV {sup 137}Cs gamma rays and then the amounts of lights were measured by the TL reader. The deposition energies in elements were calculated by theory formula and Monte Carlo simulation. The unit absorbed dose in elements by photons with different energies corresponding to the amounts of lights was calculated, which is called the thermo luminescent efficiency (η(E)). Because of the amounts of lights can be calculated by the absorbed dose in elements multiply η(E), the η(E) can be calculated by the experimental data (the amounts of lights) divided by absorbed dose. The deviation of simulation results compared with theoretical calculation results were less than 5%, so the absorbed dose in elements was calculated by simulation results in here. The change range of η(E) value, relative to 662 keV {sup 137}Cs gamma rays, is about 30% in the energy range of 33 keV to 662 keV, is in accordance by the comparison with relevant foreign literatures. The η(E) values can be used for updating the amounts of lights that are got by the direct ratio assumed relations with deposition energy in TL elements, which can largely reduce the error of calculation results of the amounts of lights. These data can be used for the design of individual dosimeter which used TLD-2000 thermo-luminescence elements, also have a certain reference value for manufacturer to improve the energy-response performance of TL elements by formulation adjustment.

  10. Serial assessment of left ventricular function in various patient groups with Tl-201 gated myocardial perfusion SPECT

    International Nuclear Information System (INIS)

    Wei Lingge; Kadoya, Masumi; Momose, Mitsuhiro; Kurozumi, Masahiro; Matsushita, Tsuyoshi; Yamada, Akira

    2007-01-01

    The present study was performed to assess stress-related left ventricular (LV) function variations in various patient groups and to determine if they were affected by sex or the type of stress experienced. We used thallium (Tl)-201 gated myocardial perfusion single-photon emission computed tomography (SPECT) for the analysis. A total of 270 patients were examined by electrocardiography-gated myocardial perfusion SPECT imaging to assess LV function. After injection of Tl-201 at a dose of 111 MBq at peak stress, SPECT scans were acquired at 10 min (after stress) and 3 h (rest) after injection on a three-headed camera. In the normal perfusion group, the mean LV ejection fraction (LVEF) was significantly higher, and both the end-diastolic volume index (EDVI) and end-systolic volume index (ESVI) were significantly lower in women than in men (P<0.05). Poststress stunning occurred in 29 of 98 patients (30.0%) in the ischemia group and in 42 of 90 patients (46.7%) in the fixed group. There was a significant difference in poststress stunning between bicycle ergometer stress and dipyridamole stress (P<0.05). In patients with normal perfusion, LVEF, EDVI, and ESVI determined by gated Tl-201 SPECT should be corrected for sex. In addition, the influence of the type of stress should be considered when assessing stress-related LV function variations. (author)

  11. Phase equilibria in TlX-Cd(Zn)X (X-S, Se, Te) systems

    International Nuclear Information System (INIS)

    Gusejnov, F.Kh.; Babanly, M.B.; Kuliev, A.A.

    1982-01-01

    The methods of DTA, RPA and measurement of the alloys microhardness have been used to investigate the phase equilibria in the TlX-Zn(Cd)X systems. It is established that the TlZn(Cd)X 2 compounds, the presence of which is mentioned in the literature earlier, do not form in these systems. The TlSe-Zn(Cd)Se systems apply to the simple eutectic type and characterized by digenerated eutectic near the TlSe. Thermodynamical analysis of the liquidus of the TlSe-CdSe and TlTe-Zn(Cd)Te systems in approximation of the regular solutions, taking into account the dissociation of tallium chalcogenides in liquid phase, is made

  12. TL and ESR based identification of gamma-irradiated frozen fish using different hydrolysis techniques

    Science.gov (United States)

    Ahn, Jae-Jun; Akram, Kashif; Shahbaz, Hafiz Muhammad; Kwon, Joong-Ho

    2014-12-01

    Frozen fish fillets (walleye Pollack and Japanese Spanish mackerel) were selected as samples for irradiation (0-10 kGy) detection trials using different hydrolysis methods. Photostimulated luminescence (PSL)-based screening analysis for gamma-irradiated frozen fillets showed low sensitivity due to limited silicate mineral contents on the samples. Same limitations were found in the thermoluminescence (TL) analysis on mineral samples isolated by density separation method. However, acid (HCl) and alkali (KOH) hydrolysis methods were effective in getting enough minerals to carry out TL analysis, which was reconfirmed through the normalization step by calculating the TL ratios (TL1/TL2). For improved electron spin resonance (ESR) analysis, alkali and enzyme (alcalase) hydrolysis methods were compared in separating minute-bone fractions. The enzymatic method provided more clear radiation-specific hydroxyapatite radicals than that of the alkaline method. Different hydrolysis methods could extend the application of TL and ESR techniques in identifying the irradiation history of frozen fish fillets.

  13. Differential diagnosis of thyroid diseases with 131I and 201TlCl scintigraphy

    International Nuclear Information System (INIS)

    Kumano, Machiko; Ishida, Osamu

    1979-01-01

    Scintigraphic study with 131 I and 201 TlCl was performed on the differential diagnosis of various kinds of thyroid disease. When thyroid nodules are cold by scintigraphy with 131 I and hot with 201 TlCl, the lesions were proved to be solid tumor, that is, mostly follicular adenoma and carcinoma, and also most probably chronic thyroiditis. Accumulation of 201 TlCl, however, is not observed in cystic lesions, and is very high with high frequency in metastatic lesion of the lymph nodes as well as the thyroid cancer, especially in well differentiated follicular carcinoma. Therefore 201 TlCl was very useful to confirm the metastatic tumors from the thyroid cancer. These features in accumulation of 131 I and 201 TlCl in thyroid disease suggest the imaging technique with 201 TlCl combined with 131 I seem to provide more pathological information on the thyroid and metastatic lesions. (author)

  14. Radiation exposure around patients after 201Tl-myocardial scintigraphy

    International Nuclear Information System (INIS)

    Kurtaran, A.; Preitfellner, J.; Kohoutek, D.; Tousek, A.; Virgolini, I.; Havlik, E.

    1997-01-01

    Aim: It was the aim of the study to assess the additional radiation exposure to patients, attendents and nurses by patients who are undergoing nuclear medicine investigations (myocardial scintigraphy) with 201 Tl-chloride ( 201 Tl-Cl). Methode: In 16 cases the dose rates at 0.5, 1 and 2 m distance from patients were measured at 0.5, 1.5, 3-4 and 24, in some cases until 370 h after administration of 100±10 MBq 201 Tl-Cl. From the time courses of the dose rates around the patients the possible radiation exposure of other persons were estimated. Results: The initial values of the dose rate were 3.82 μSv/h at 0.5 m, 1.18 μSv/h at 1 m and 0.30 μSv/h at 2 m distance from the patients respectively. The dose rates were decreasing following a monoexponential course with an effective half-life of 60 h. The maximum doses to other persons at 1 m distance from the patients were determined by considering three scenarios. The values were 13 μSv in the waiting room, 26 μSv for nurses working in the ward and 105 μSv for persons living in the same household. Conclusion: Even at very restrictive assumptions the doses were far below the maximum permissible dose to non-radiation workers set by radiation protection regulations (1.5 mSv per year). (orig.) [de

  15. Dosimetric characteristics of LKB:Cu,P solid TL detector

    International Nuclear Information System (INIS)

    Hashim, S.; Alajerami, Y.S.M.; Ghoshal, S.K.; Saleh, M.A.; Saripan, M.I.; Kadir, A.B.A.; Bradley, D.A.; Alzimami, K.

    2014-01-01

    The dosimetric characteristics of newly developed borate glass dosimeter modified with lithium and potassium carbonate (LKB) and co-doped with CuO and NH 4 H 2 PO 4 are reported. Broad peaks in the absence of any sharp peak confirms the amorphous nature of the prepared glass. A simple glow curve of Cu doped sample is observed with a single prominent peak (T m ) at 220 °C. The TL intensity response shows an enhancement of ∼100 times due to the addition of CuO (0.1 mol%) to LKB compound. A further enhancement of the intensity by a factor of 3 from the addition of 0.25 mol% NH 4 H 2 PO 4 as a co-dopant impurity is attributed to the creation of extra electron traps with consequent increase in energy transfer of radiation recombination centers. The TL yield performance of LKB:Cu,P with Z eff ≈8.92 is approximately seventeen times less sensitive compared to LiF:Mg,Ti (TLD-100). The proposed dosimeter shows good linearity up to 10 3 Gy, minimal fading and photon energy independence. These attractive features offered by our dosimeter is expected to pave the way towards dosimetric applications. - Highlights: • The NH 4 H 2 PO 4 impurities are cross linked with the CuO defect. • The addition of NH 4 H 2 PO 4 as a co-dopant improved the TL intensity by a factor of 3. • The proposed dosimeter shows good linearity up to 10 3 Gy. • Minimal fading and photon energy independence were observed

  16. Relative efficiency of anuran sampling methods in a restinga habitat (Jurubatiba, Rio de Janeiro, Brazil

    Directory of Open Access Journals (Sweden)

    C. F. D. Rocha

    Full Text Available Studies on anurans in restinga habitats are few and, as a result, there is little information on which methods are more efficient for sampling them in this environment. Ten methods are usually used for sampling anuran communities in tropical and sub-tropical areas. In this study we evaluate which methods are more appropriate for this purpose in the restinga environment of Parque Nacional da Restinga de Jurubatiba. We analyzed six methods among those usually used for anuran samplings. For each method, we recorded the total amount of time spent (in min., the number of researchers involved, and the number of species captured. We calculated a capture efficiency index (time necessary for a researcher to capture an individual frog in order to make comparable the data obtained. Of the methods analyzed, the species inventory (9.7 min/searcher /ind.- MSI; richness = 6; abundance = 23 and the breeding site survey (9.5 MSI; richness = 4; abundance = 22 were the most efficient. The visual encounter inventory (45.0 MSI and patch sampling (65.0 MSI methods were of comparatively lower efficiency restinga, whereas the plot sampling and the pit-fall traps with drift-fence methods resulted in no frog capture. We conclude that there is a considerable difference in efficiency of methods used in the restinga environment and that the complete species inventory method is highly efficient for sampling frogs in the restinga studied and may be so in other restinga environments. Methods that are usually efficient in forested areas seem to be of little value in open restinga habitats.

  17. Relative efficiency of anuran sampling methods in a restinga habitat (Jurubatiba, Rio de Janeiro, Brazil).

    Science.gov (United States)

    Rocha, C F D; Van Sluys, M; Hatano, F H; Boquimpani-Freitas, L; Marra, R V; Marques, R V

    2004-11-01

    Studies on anurans in restinga habitats are few and, as a result, there is little information on which methods are more efficient for sampling them in this environment. Ten methods are usually used for sampling anuran communities in tropical and sub-tropical areas. In this study we evaluate which methods are more appropriate for this purpose in the restinga environment of Parque Nacional da Restinga de Jurubatiba. We analyzed six methods among those usually used for anuran samplings. For each method, we recorded the total amount of time spent (in min.), the number of researchers involved, and the number of species captured. We calculated a capture efficiency index (time necessary for a researcher to capture an individual frog) in order to make comparable the data obtained. Of the methods analyzed, the species inventory (9.7 min/searcher /ind.- MSI; richness = 6; abundance = 23) and the breeding site survey (9.5 MSI; richness = 4; abundance = 22) were the most efficient. The visual encounter inventory (45.0 MSI) and patch sampling (65.0 MSI) methods were of comparatively lower efficiency restinga, whereas the plot sampling and the pit-fall traps with drift-fence methods resulted in no frog capture. We conclude that there is a considerable difference in efficiency of methods used in the restinga environment and that the complete species inventory method is highly efficient for sampling frogs in the restinga studied and may be so in other restinga environments. Methods that are usually efficient in forested areas seem to be of little value in open restinga habitats.

  18. Estimation of Resource Productivity and Efficiency: An Extended Evaluation of Sustainability Related to Material Flow

    Directory of Open Access Journals (Sweden)

    Pin-Chih Wang

    2014-09-01

    Full Text Available This study is intended to conduct an extended evaluation of sustainability based on the material flow analysis of resource productivity. We first present updated information on the material flow analysis (MFA database in Taiwan. Essential indicators are selected to quantify resource productivity associated with the economy-wide MFA of Taiwan. The study also applies the IPAT (impact-population-affluence-technology master equation to measure trends of material use efficiency in Taiwan and to compare them with those of other Asia-Pacific countries. An extended evaluation of efficiency, in comparison with selected economies by applying data envelopment analysis (DEA, is conducted accordingly. The Malmquist Productivity Index (MPI is thereby adopted to quantify the patterns and the associated changes of efficiency. Observations and summaries can be described as follows. Based on the MFA of the Taiwanese economy, the average growth rates of domestic material input (DMI; 2.83% and domestic material consumption (DMC; 2.13% in the past two decades were both less than that of gross domestic product (GDP; 4.95%. The decoupling of environmental pressures from economic growth can be observed. In terms of the decomposition analysis of the IPAT equation and in comparison with 38 other economies, the material use efficiency of Taiwan did not perform as well as its economic growth. The DEA comparisons of resource productivity show that Denmark, Germany, Luxembourg, Malta, Netherlands, United Kingdom and Japan performed the best in 2008. Since the MPI consists of technological change (frontier-shift or innovation and efficiency change (catch-up, the change in efficiency (catch-up of Taiwan has not been accomplished as expected in spite of the increase in its technological efficiency.

  19. Relative Efficiency Indicators of the Credit Management Process in a Colombian Bank by Means of Data Envelopment Analysis (DEA)

    OpenAIRE

    Sánchez-Gooding, Sandra Paola; Universidad Nacional de Colombia; Rodríguez-Lozano, Gloria Isabel; Universidad Nacional de Colombia

    2017-01-01

    The purpose of this work is to measure the relative efficiency of the units that take part in the credit management process in a Colombian bank by means of the use of Data Envelopment Analysis (DEA). Using a doublé optimization process, this advanced linear programmingmethodology generates a single relative efficiency index for each one of the units being studied, although it is capable of including multiple resources and multiple outputs. In the bank that was used as the object of this study...

  20. Model-based visual tracking the OpenTL framework

    CERN Document Server

    Panin, Giorgio

    2011-01-01

    This book has two main goals: to provide a unifed and structured overview of this growing field, as well as to propose a corresponding software framework, the OpenTL library, developed by the author and his working group at TUM-Informatik. The main objective of this work is to show, how most real-world application scenarios can be naturally cast into a common description vocabulary, and therefore implemented and tested in a fully modular and scalable way, through the defnition of a layered, object-oriented software architecture.The resulting architecture covers in a seamless way all processin

  1. Design and manufacture of TL analyser by using the microcomputer

    International Nuclear Information System (INIS)

    Doh, Sih Hong; Woo, Chong Ho

    1986-01-01

    This paper describes the design of the thermoluminescence analyser using microcomputer. TL analyser is designed to perform the three step heat treatment, such as pre-read heating, readout procedure and post-heating (or pre-irradiation ) anneal. We used a 12-bit A/D converter to get the precise measurement and the phase control method to control the heating temperature. Since the used Apple II microcomputer is cheap and popular, it is possible to design the economical system. Experimental results showed the successful operation with flexibility. The error of temperature control was less than ± 0.2% of the expected value. (Author)

  2. Progress in TL Dating at Risø

    DEFF Research Database (Denmark)

    Mejdahl, V.

    1972-01-01

    This article outlines the thermoluminescent dating technique employed at Risö. The intensity of beta and gamma radiation is determined by means of the TL phosphors CaSO4:Mn and CaSO4:Dy, and the determination of accumulated exposure is based on quartz and feldspar inclusions with a size of 0.......3–0.5 mm. Results are presented of a dating programme comprising sherds, bricks, burned stones and burned clay (from kilns) from seventeen excavation sites. The age of the sites ranged from a.d. 1600 to 4000 b.c....

  3. Environmental monitoring by CaSO4:Dy TL dosimeters

    International Nuclear Information System (INIS)

    Deme, S.; Szabo, P.P.

    1975-12-01

    The thermoluminescent dosimeters of high sensitivity are useful for monitoring the area near nuclear installations. CaSO 4 :Dy TL dosimeters have high sensitivity and low fading so that by means of them the dose from the background can be measured with an accuracy of 10-20%. An increase of 2 mR in the background can be observed and doses as high as 1000R can be registered with an accuracy of 5%. The measuring method and results are reported here. For two years these CaSO 4 :Dy dosimeters have been successfully used at the site of the Central Research Institute for Physics. (K.A.)

  4. MF-plan till företaget Design TL

    OpenAIRE

    Virtanen, Aino

    2015-01-01

    Examensarbetet gjordes för företaget Design TL med uppgiften att göra en mark-nadsföringsplan för företaget som skall starta verksamheten 2016. Detta examensar-bete har utförts genom litteraturstudie och information av uppdragsgivaren. Upp-dragsgivaren var Tarja Lamberg. Företaget sysslar med konst, konsthantverks plane-ring och design, tillverkning och försäljning. Uppdragsgivaren gav mig fria händer med planet, det enda som skulle tas i beakta var den begränsade budgeten. Teoride-len satte...

  5. Spins of superdeformed rotational bands in Tl isotopes

    Energy Technology Data Exchange (ETDEWEB)

    Dadwal, Anshul; Mittal, H.M. [Dr. B.R. Ambedkar National Institute of Technology, Jalandhar (India)

    2017-01-15

    The two-parameter model defined for even-even nuclei viz. soft-rotor formula is used to assign the band-head spin of the 17 rotational bands in Tl isotopes. The least-squares fitting method is employed to obtain the spins of these bands in the A ∝ 190 mass region. The calculated transition energies are found to depend sensitively on the proposed spin. Whenever a correct spin assignment is made, the calculated and experimental transition energies coincide very well. The dynamic moment of inertia is also calculated and its variation with rotational frequency is explored. (orig.)

  6. Double blocking in the superdeformed {sup 192}Tl nucleus

    Energy Technology Data Exchange (ETDEWEB)

    Liang, Y; Carpenter, M P; Janssens, R V.F.; Ahmad, I; Henry, R; Khoo, T L; Lauritsen, T [Argonne National Lab., IL (United States); Soramel, F [Padova University, Padova (Italy); Pilotte, S [Ottawa Univ., ON (Canada); Lewis, J M; Riedinger, L L; Yu, C H [Tennessee Univ., Knoxville, TN (United States); Garg, U; Reviol, W [Notre Dame Univ., IN (United States); Bearden, I G [Purdue Univ., Lafayette, IN (United States)

    1992-08-01

    Six superdeformed bands have been found in the nucleus {sup 192}Tl. For two of the bands, the dynamic moment of inertia J{sup (2)} is found to be constant with the rotational frequency {Dirac_h}{omega}. This result can be understood in terms of Pauli blocking of quasiparticle alignments in intruder orbitals, and represents the first experimental evidence that the alignment of these intruders is responsible for the smooth rise in J{sup (2)} seen in other superdeformed nuclei of this mass region. (author). 18 refs., 2 figs.

  7. Scintigraphic detection of ischemic and other myocardial lesions using 201Tl

    International Nuclear Information System (INIS)

    Duska, F.; Novak, J.; Vizda, J.; Kubicek, J.; Kafka, P.

    1981-01-01

    Current knowledge of the myocardium scintiscanning using 201 Tl is briefly outlined. The principle is shown of 201 Tl cumulation in a healthy myocardium and the use of the radionuclide is justified. Heart scintiscanning after exercise or after administration of drugs increasing the blood flow through the coronaries allows detecting latent ischaemic heart disease. 201 Tl scintigraphy can also be used for diagnosing the myocardial infarction, angina pectoris and other heart diseases. (J.P.)

  8. Electronic Structure of TlBa2CaCu2O(7-Delta)

    Science.gov (United States)

    Vasquez, R. P.; Novikov, D. L.; Freeman, A. J.; Siegal, M. P.

    1997-01-01

    The core levels of TlBa2CaCu2O(7-delta) (Tl-1212) epitaxial films have been measured with X-ray photoelectron spectroscopy (XPS). The valence electronic structure has been determined using the full-potential linear muffin-tin-orbital band-structure method and measured with XPS. The calculations show that a van Hove singularity (VHS) lies above the Fermi level (E(sub F)) for the stoichiometric compound (delta = 0.5), while for 50% oxygen vacancies in the Tl-O layer (delta = 0.5) E(sub F) is in close proximity to the VHS. Samples annealed in nitrogen (to reduce the hole overdoping by the removal of oxygen) exhibit higher core-level binding energies and a higher T(sub c), consistent with a shift of E(sub F) closer to the VHS. Comparisons are made to the core levels and valence bands of Tl2Ba2CaCu2O(8 + delta)(Tl-2212) and HgBa2CaCu2O)6 + delta) (Hg- 1212). The similarity of the Cu 2p(sub 3/2) spectra for Tl-1212 and Tl-2212 indicates that the number of Tl-O layers has little effect on the Cu-O bonding. However, the Tl-1212 and Hg-1212 Cu 2p(sub 3/2) signals exhibit differences which suggest that the replacement of T(sup 3+) with Hg(sup 2+) results in a decrease in the O 2p right arrow Cu 3d charge-transfer energy and differences in the probabilities of planar vs apical oxygen charge transfer and/or Zhang-Rice singlet-state formation. Differences between the Tl-1212 and the Tl-2212 and Hg-1212 measured valence bands are consistent with the calculated Cu 3d and (Tl,Hg) 6s/5d partial densities of states.

  9. Photo-TL in CaSO4:Dy: high exposure dosimetry

    International Nuclear Information System (INIS)

    Caldas, L.V.E.; Mayhugh, M.R.

    1974-01-01

    CaSO 4 :Dy exposed to 10 3 to 10 8 R then annealed in the range 280 to 400 0 C displays little TL in the major dosimetry peak near 200 0 C. Subsequent illumination with 250 nm light reinduces the 200 0 C TL. This radiation-enabled photo-TL is roughly proportional to the square root of the enabling exposure at least to 10 8 R. (auth)

  10. Microcomputer-Controlled Reader Systems for Archaeological and Geological TL Dating

    DEFF Research Database (Denmark)

    Bøtter-Jensen, Lars; Mejdahl, V.

    1984-01-01

    Two fully automated TL reader systems for TL dating and a manually operated reader for research purpose were put into operation during 1982-3. All systems are controlled by HP-85 or HP-86 microcomputers; thus flexibility in selection of measurement parameters, calculation of TL signals and displa...... the archaeological and geological ages. The principle of the measurement procedures are described, and dating results are presented to illustrate the performance of the systems...

  11. Recovery of 201Tl by ion exchange chromatography from proton bombarded thallium cyclotron targets

    International Nuclear Information System (INIS)

    Walt, T.N. van der; Naidoo, C.

    2000-01-01

    A method based on ion exchange chromatography is presented for the recovery of 201 Tl and its precursor 201 Pb from proton bombarded natural thallium cyclotron targets. After bombardment the target is dissolved in diluted nitric acid. Water, hydrazine and ammonium acetate are added to the solution and the lead radioisotopes separated from the thallium by cation exchange chromatography on a Bio-Rex 70 column. The sorbed lead radioisotopes are eluted with dilute nitric acid and the separation repeated on a second Bio-Rex 70 column. After elution of the remaining thallium the column is left for 32 hours and the 201 Tl formed by decay of 201 Pb is eluted with an ammonium acetate solution. The 201 Tl eluate is acidified with a HNO 3 -HBr-Br 2 mixture and the resulting solution is passed through an AG MP-1 anion exchanger column to remove any remaining lead isotopes. The 201 Tl is eluted with a hydrazine solution, the eluate evaporated to dryness and the 201 Tl finally dissolved in an appropriate solution to produce a 201 TlCl solution suitable for medical use. A high quality 201 Tl product is obtained containing ≤ 0.1 μg of Tl/mCi (37 MBq) 201 Tl. The radionuclidic impurities are less than the maximum values specified by the US Pharmacopoeia and the British Pharmacopoeia. (orig.)

  12. Self-trapping nature of Tl nanoclusters on the Si(111)-7x7 surface

    International Nuclear Information System (INIS)

    Hwang, C G; Kim, N D; Lee, G; Shin, S Y; Kim, J S; Chung, J W

    2008-01-01

    We have studied properties of thallium (Tl) nanoclusters formed on the Si(111)-7x7 surface at room temperature (RT) by utilizing photoemission spectroscopy (PES) and high-resolution electron-energy-loss spectroscopy (HREELS) combined with first principles calculations. Our PES data reveal that the surface states stemming from the Si substrate remain quite inert with Tl adsorption producing no Tl-induced state until saturation at Tl coverage θ=0.21 monolayers. Such a behavior, in sharp contrast with the extremely reactive surface states upon the formation of Na or Li nanoclusters, together with the presence of a unique Tl-induced loss peak in HREELS spectra suggests no strong Si-Tl bonding, and is well understood in terms of gradual filling of Si dangling bonds with increasing θ. Our calculation further indicates the presence of several metastable atomic structures of Tl nanoclusters at RT rapidly transforming from one to another faster than 10 10 flippings per second. We thus conclude that the highly mobile Tl atoms form self-trapped nanoclusters within the attractive basins of the Si substrate at RT with several metastable phases. The mobile and multi-phased nature of Tl nanoclusters not only accounts for all the existing experimental observations available at present, but also provides an example of self-trapping of atoms in a nanometre-scale region

  13. Auto-regenerative TL dating with zircon inclusions from fired materials

    International Nuclear Information System (INIS)

    Templer, R.H.; Smith, B.W.

    1988-01-01

    In this paper it is shown that it is possible to date fired material using zircon inclusions. The effects of zoning and anomalous fading are overcome using an auto-regenerative dating procedure. The high radioactivity of the grains gives a measurable self-induced TL (thermoluminescence) signal within a few months. Comparison of this ''auto-regenerated'' TL with the natural TL (which has accumulated since the firing) yields the age of the material. A sensitive TL reader capable of recording the auto-regenerated signal after 6 months is also described, and the results of age determinations on a number of known age samples are presented. (author)

  14. Two cases of hyperparathyroidism revealed by /sup 201/Tl-chloride

    Energy Technology Data Exchange (ETDEWEB)

    Otsuka, Kokichi; Asano, Haruko; Moriyama, Shigeharu (Okayama Red Cross Hospital (Japan))

    1983-08-01

    /sup 201/Tl scintigraphy at 15 min and 120 min after intravenous injection of /sup 201/TlCl revealed a parathyroidal adenoma (1.7g) in a 49-year-old female patient with hyperthyroidism complicated by renal calculi and that (1.8g) in a 58-year-old female patient without symptoms. /sup 75/Se could be substituted by /sup 201/Tl which was useful for localizing parathyroidal adenoma in hyperparathyroidism. /sup 201/Tl scintigraphy revealed the adenoma which was not palpable. The smallest adenoma detected by it was 0.9g.

  15. The efficiency of tax expenses related to sustainable development. Communication to the Senate Commission for Finances

    International Nuclear Information System (INIS)

    2016-09-01

    Tax expenses correspond to losses of tax direct incomes due to various legal measures (derogations, tax reductions, tax credits) which aim at supporting or promoting various behaviours and activities, notably in favour of the protection of the environment, but their efficiency (in this case, their environmental efficiency), i.e. their ability to reach the ecological objective at a reasonable cost, is difficult to assess. Thus, this report proposes a detailed analysis and comparison of the different tax expenses which have been existing in France between 2010 and 2015 and have been introduced to promote a sustainable development. On the way, the authors identify some failures in the steering of these tax expenses, and show that the efficiency is very much uneven depending on the sector (housing, transports, protection of natural resources). They notably outlines the prevailing weight of expenses unfavourable to a sustainable development (multiple objectives which are often difficult to assess, arrangements without consistency, limits of the public commitment), a failing follow-up (unsuited tools, badly assessed costs, arrangements not enough controlled), and an uncertain efficiency (modest results of the incentive policy for housing renovation, contradictions in policy of transports, and an under-developed policy of protection of natural resources). A set of recommendations is however proposed

  16. Genetic parameters and predicted selection results for maternal traits related to lactation efficiency in sows

    NARCIS (Netherlands)

    Bergsma, R.; Kanis, E.; Verstegen, M.W.A.

    2008-01-01

    The increased productivity of sows increases the risk of a more pronounced negative energy balance during lactation. One possibility to prevent this is to increase the lactation efficiency (LE) genetically and thereby increase milk output for a given feed intake and mobilization of body tissue. The

  17. Program Evaluation: Roles and Responsibilities of Boards of Education Relative to Thorough and Efficient Legislation.

    Science.gov (United States)

    Research for Better Schools, Inc., Philadelphia, PA.

    The process for providing a "thorough and efficient" (T & E) education according to New Jersey statutes and regulations involves six basic steps. This document suggests procedures for handling the fifth step, educational program evaluation. Processes discussed include committee formation, evaluation planning, action plan…

  18. Human Resource Management Strategies and Teacher's Efficiency within Schools: A Co-Relational Study

    Science.gov (United States)

    Hashmi, Kiran

    2014-01-01

    The aim of the paper is to study Human Resource Management and Development (HRMD) strategies and their effect on teachers' efficiency within the Catholic Board of Education (CBE) schools of Pakistan whose teachers are graduates in educational leadership courses from a private teacher education institutes in Karachi. The study endeavored to build a…

  19. Clinical significance of 201Tl reverse redistribution in patients with aorto-coronary bypass surgery

    International Nuclear Information System (INIS)

    Nishimura, Tsunehiko; Uehara, Tashiisa; Hayashida, Kohei; Kozuka, Takahira

    1987-01-01

    Detection of myocardial ischemia by the stress thallium scan has traditionally been performed using transient defect analysis on exercise, followed by redistribution studies. Worsening of the 201 Tl myocardial image from exercise to redistribution is referred to as reverse redistribution. In this study, we found reverse redistribution in 10 (21%) of 48 angina pectoris patients who had undergone aortocoronary bypass surgery. The clinical significance of this phenomenon in these patients was investigated in relation to angiographic and surgical findings. Reverse redistribution was found to occur in regions which were supplied by bypass grafts. These areas showed increased coronary blood flow and rapid thallium washout. Our results indicate that a perfusion defect in the bypass region of the redistribution image might be caused by relatively rapid washout in the bypass graft region compared to the adjacent normal myocardium. These results should be considered in the clinical interpretation of stress thallium scans. (orig.)

  20. Determination of absolute detection efficiencies for detectors of interest in homeland security

    International Nuclear Information System (INIS)

    Ayaz-Maierhafer, Birsen; DeVol, Timothy A.

    2007-01-01

    The absolute total and absolute peak detection efficiencies of gamma ray detector materials NaI:Tl, CdZnTe, HPGe, HPXe, LaBr 3 :Ce and LaCl 3 :Ce were simulated and compared to that of polyvinyltoluene (PVT). The dimensions of the PVT detector were 188.82 cmx60.96 cmx5.08 cm, which is a typical size for a single-panel portal monitor. The absolute total and peak detection efficiencies for these detector materials for the point, line and spherical source geometries of 60 Co (1332 keV), 137 Cs (662 keV) and 241 Am (59.5 keV) were simulated at various source-to-detector distances using the Monte Carlo N-Particle software (MCNP5-V1.30). The comparison of the absolute total detection efficiencies for a point, line and spherical source geometry of 60 Co and 137 Cs at different source-to-detector distance showed that the absolute detection efficiency for PVT is higher relative to the other detectors of typical dimensions for that material. However, the absolute peak detection efficiency of some of these detectors are higher relative to PVT, for example the absolute peak detection efficiency of NaI:Tl (7.62 cm diameterx7.62 cm long), HPGe (7.62 cm diameterx7.62 cm long), HPXe (11.43 cm diameterx60.96 cm long), and LaCl 3 :Ce (5.08 cm diameterx5.08 cm long) are all greater than that of a 188.82 cmx60.96 cmx5.08 cm PVT detector for 60 Co and 137 Cs for all geometries studied. The absolute total and absolute peak detection efficiencies of a right circular cylinder of NaI:Tl with various diameters and thicknesses were determined for a point source. The effect of changing the solid angle on the NaI:Tl detectors showed that with increasing solid angle and detector thickness, the absolute efficiency increases. This work establishes a common basis for differentiating detector materials for passive portal monitoring of gamma ray radiation

  1. Radiation accident dosimetry: TL properties of mobile phone screen glass

    International Nuclear Information System (INIS)

    Bassinet, C.; Pirault, N.; Baumann, M.; Clairand, I.

    2014-01-01

    Mobile phones are carried by a large part of the population and previous studies have shown that they may be able to function as individual fortuitous dosimeters in case of radiological accident. This study deals with thermoluminescence (TL) properties of mobile phone screen glass. The presence of a significant background signal which partially overlaps with the radiation-induced signal is a serious issue for dose reconstruction. A mechanical method to reduce this signal using a diamond grinding bit is presented. An over-response at low energy (∼50 keV) is observed for two investigated glasses. The results of a dose recovery test using a single-aliquot regenerative-dose (SAR) procedure are discussed. - Highlights: • Mobile phone screen glass is a promising material for retrospective dosimetry. • The TL non-radiation induced background signal can be significantly reduced by a mechanical method. • A dose recovery test using an SAR procedure was successfully carried out for the investigated glass

  2. Measurements of the light conversion efficiency of lithium borate for alpha particles relative to cobalt-60 gamma radiation

    Energy Technology Data Exchange (ETDEWEB)

    Bartlett, D.T.; Wall, B.F.; Fisher, E.S. (National Radiological Protection Board, Harwell (UK))

    1982-01-01

    The results are reported of measurements of the light conversion efficiencies of lithium borate TLD phosphor of British Nuclear Fuels Ltd. manufacture to 5.65 MeV and 2.4 MeV alpha particles relative to /sup 60/Co gamma radiation.

  3. The electrolysis of a carbonate-borate solution with a platinum anode : II. Relation between current efficiency and perborate concentration

    NARCIS (Netherlands)

    Wiel, van der P.M.; Janssen, L.J.J.; Hoogland, J.G.

    1971-01-01

    The current efficiency R (cor. for the chem. disproportionation of H2O2 in the bulk of electrolyte) of the electrolytic formation of perborate decreases with increasing concn. of H2O2. The factors causing this decrease were investigated. The relation between R and H2O2% and the diffusion coeff. of

  4. Exploring the relation between process design and efficiency in high-volume cataract pathways from a lean thinking perspective

    NARCIS (Netherlands)

    van Vliet, Ellen J.; Bredenhoff, E.; Bredenhoff, Eelco; Sermeus, Walter; Kop, Lucas M.; Sol, Johannes C.A.; van Harten, Willem H.

    2011-01-01

    Objective: To compare process designs of three high-volume cataract pathways in a lean thinking framework and to explore how efficiency in terms of lead times, hospital visits and costs is related to process design. Design: International retrospective comparative benchmark study with a mixed-method

  5. Lipofectamine and related cationic lipids strongly improve adenoviral infection efficiency of primitive human hematopoietic cells.

    Science.gov (United States)

    Byk, T; Haddada, H; Vainchenker, W; Louache, F

    1998-11-20

    Adenoviral vectors have the potential to infect a large number of cell types including quiescent cells. Their use in hematopoietic cells is limited by the episomal form of their DNA, leading to transgene loss in the progeny cells. However, the use of this vector may be interesting for short-term in vitro modifications of primitive human hematopoietic cells. Therefore, we have investigated the ability of adenovirus to transduce cord blood CD34+ cells. Several promoters were tested using the lacZ reporter gene. The PGK and CMV promoters induced transgene expression in 18-25% of the cells, whereas the HTLV-I and especially the RSV promoter were almost inactive. To improve infection efficiency, adenovirus was complexed with cationic lipids. Lipofectamine, Cellfectin, and RPR120535b, but not Lipofectin, Lipofectace, or DOTAP, markedly improved transgene expression in CD34+ cells (from 19 to 35%). Lipofectamine strongly enhanced infection efficiency of the poorly infectable primitive CD34+CD38low cells (from 11 to 28%) whereas the more mature CD34+CD38+ cells were only slightly affected (from 24 to 31%). Lipofectamine tripled the infection of CFU-GMs and LTC-ICs derived from the CD34+CD38low cell fraction (from 4 to 12% and from 5 to 16%, respectively) and doubled that of BFU-Es (from 13 to 26%). We conclude that cationic lipids can markedly increase the efficiency of adenovirus-mediated gene transfer into primitive hematopoietic cells.

  6. Tl response of KMgF{sub 3}: Lu + PTFE at ultraviolet radiation; Respuesta Tl de KMgF{sub 3}: Lu + PTFE a radiacion ultravioleta

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez, P R [Instituto Nacional de Investigaciones Nucleares, A.P. 18 -1027, 11801 Mexico D.F. (Mexico); Alarcon, N G [Facultad de Quimica, Universidad Autonoma del Estado de Mexico. Paseo Tollocan, Esq. con Jesus Carranza, 50180 Toluca, Estado de Mexico (Mexico); Furetta, C; Azorin, J [Universidad Autonoma Metropolitana- Iztapalapa, San Rafael Atlixco 186, 09340 Mexico. D.F. (Mexico)

    2003-07-01

    Ionizing radiation has different types of interaction with a crystalline solid. However, only few effects are interesting to optimize some thermoluminescent (Tl) properties of certain Tl materials. This paper presents results obtained by irradiating KMgF{sub 3}: Lu + Ptfe Tl dosimeters with ultraviolet (UV) radiation previously exposed to gamma radiation. These results showed that those dosimeters not exposed previously to gamma radiation did not presented any Tl signal. Meanwhile, those previously submitted to gamma irradiation showed that their sensitivity was increased as the gamma dose increased. The glow curve of sensitized KMgF{sub 3}: Lu + Ptfe exposed to UV radiation, presented the dosimetric pea at 212 C. This makes this material to be promissory for measuring UV radiation. (Author)

  7. Study of /sup 201/Tl uptake by bone and bone marrow on /sup 201/Tl scintigraphy. With special reference to bone marrow abnormalities

    Energy Technology Data Exchange (ETDEWEB)

    Fujii, Tadashige; Tanaka, Masao; Hirose, Yoshiki; Hirayama, Jiro; Handa, Kenjiro; Nakanishi, Fumiko; Yano, Kesato; Ueda, Hitoshi

    1989-04-01

    Thallium-201 (Tl-201) uptake in the bone and bone marrow was examined in a total of 93 patients with various diseases. Sternal uptake of Tl-201 was observed when patients had bone marrow abnormality especially associated with hematopoietic disease. It was associated with proliferation of immature cells and of various types of bone marrow cells, especially erythroblastic and plasma cells. Whole-body Tl-201 scanning showed a high uptake (82%) in the sternum, chest, lumbar vertebrae, and pelvis. Thallium-201 was definitively taken up by the sternum in polycythemia (5/41), hemolytic anemia (2/2), iron deficiency anemia (2/2), and multiple myeloma (2/5). For leukemia, Tl-201 uptake was slight or negative. Thallium-201 scanning proved useful in visualizing bone marrow abnormality, although careful interpretation of bone and bone marrow uptake is required. (Namekawa, K).

  8. Relative efficiency of hydrogen technologies for the hydrogen economy : a fuzzy AHP/DEA hybrid model approach

    International Nuclear Information System (INIS)

    Lee, S.

    2009-01-01

    As a provider of national energy security, the Korean Institute of Energy Research is seeking to establish a long term strategic technology roadmap for a hydrogen-based economy. This paper addressed 5 criteria regarding the strategy, notably economic impact, commercial potential, inner capacity, technical spinoff, and development cost. The fuzzy AHP and DEA hybrid model were used in a two-stage multi-criteria decision making approach to evaluate the relative efficiency of hydrogen technologies for the hydrogen economy. The fuzzy analytic hierarchy process reflects the uncertainty of human thoughts with interval values instead of clear-cut numbers. It therefore allocates the relative importance of 4 criteria, notably economic impact, commercial potential, inner capacity and technical spin-off. The relative efficiency of hydrogen technologies for the hydrogen economy can be measured via data envelopment analysis. It was concluded that the scientific decision making approach can be used effectively to allocate research and development resources and activities

  9. Relative efficiency of hydrogen technologies for the hydrogen economy : a fuzzy AHP/DEA hybrid model approach

    Energy Technology Data Exchange (ETDEWEB)

    Lee, S. [Korea Inst. of Energy Research, Daejeon (Korea, Republic of). Energy Policy Research Division; Mogi, G. [Tokyo Univ., (Japan). Dept. of Technology Management for Innovation, Graduate School of Engineering; Kim, J. [Korea Inst. of Energy Research, Daejeon (Korea, Republic of)

    2009-07-01

    As a provider of national energy security, the Korean Institute of Energy Research is seeking to establish a long term strategic technology roadmap for a hydrogen-based economy. This paper addressed 5 criteria regarding the strategy, notably economic impact, commercial potential, inner capacity, technical spinoff, and development cost. The fuzzy AHP and DEA hybrid model were used in a two-stage multi-criteria decision making approach to evaluate the relative efficiency of hydrogen technologies for the hydrogen economy. The fuzzy analytic hierarchy process reflects the uncertainty of human thoughts with interval values instead of clear-cut numbers. It therefore allocates the relative importance of 4 criteria, notably economic impact, commercial potential, inner capacity and technical spin-off. The relative efficiency of hydrogen technologies for the hydrogen economy can be measured via data envelopment analysis. It was concluded that the scientific decision making approach can be used effectively to allocate research and development resources and activities.

  10. Investigation of the gamma radiation from the inelastic scattering of 2.75 MeV on 203Tl and 205Tl

    International Nuclear Information System (INIS)

    Hegewisch, S.

    1976-01-01

    The experimental presupositions for the measurements of (n,n'γ) reactions with time of flight discrimination have been established. By an investigation of the isotopes 203 Tl and 205 Tl with this method 120 gamma-transitions could be determined. The exact evaluation of their energies and intensities led to a completion of the level diagrams. The enrgies could be determined with a precision nearly one order of magnitude higher than the values existing hither to. (orig./WL) [de

  11. The superconductor (Tl,Hg,Ca)2(Ba,Sr)2(Ca,Sr,Tl)Cu2O7.6

    International Nuclear Information System (INIS)

    Valldor, M.; Bryntse, I.; Morawski, A.

    2002-01-01

    In the title 2212-type superconductor (thallium mercury calcium barium strontium copper oxide), which contains both Tl and Hg in the charge reservoir (CR), Sr is located at both alkali-earth (AE) metal sites. Ca enters the CR at the same time as Tl shares the smaller AE site, which increases the apical Cu-Cu distance significantly. The structure causes the superconducting Cu-O layers to become significantly puckered. (orig.)

  12. Antiferromagnetism Induced in the Vortex Core of Tl2Ba2CuO6++δ Probed by Spatially-Resolved 205Tl-NMR

    International Nuclear Information System (INIS)

    Kumagai, K.; Kakuyanagi, K.; Matsuda, Y.; Hasegawa, T.

    2003-01-01

    Magnetism in the vortex core state has been studied by spatially-resolved NMR. The nuclear spin lattice relaxation rate T 1 -1 of 205 Tl in nearly optimal-doped Tl 2 Ba 2 CuO 6+ δ (T c =85 K) is significantly enhanced in the vortex core region. The NMR results suggest that the suppression of the d-wave superconducting order parameter in the vortex core leads to the nucleation of islands with local antiferromagnetic (AF) order. (author)

  13. Household lifestyle, energy related practices and perceptions of energy efficiency: Evidence from Kitwe, Zambia

    Directory of Open Access Journals (Sweden)

    Lilias Makashini

    2014-08-01

    Full Text Available Southern Africa is noted for not only constant power shortages but also poor access to electricity. In Zambia, for example, 75% of the population does not have access to electricity. This is partly because although Zambia has one of the lowest energy tariffs in Southern Africa, when compared with household monthly income, the resource is still reasonably unaffordable. Therefore, there is need to find innovative ways of reducing energy cost. Recent studies have indicated that there are patterns that show that there is a relationship between households' lifestyles and energy consumption. This means that understanding household lifestyles and how that impacts on energy use would be crucial in helping occupants to change their behaviours. This would result in the minimisation of energy consumption and thus a reduction in energy bills. However, there is a dearth of scholarly literature about households' lifestyles and their impacts on energy consumption in most developing countries including Zambia. This study investigates the perceptions of different lifestyles on household energy consumption and knowledge about energy efficiency in the city of Kitwe, the second largest city in Zambia. Motivation and barriers to energy efficiency have also been investigated. To achieve this, a mixed research approach was adopted. Firstly, a quantitative closed structured questionnaire instrument was used to collect data from 59 households in Kitwe. Secondly, mini-focus group discussions (average size of 5 ― brought about by the curiosity of residents and hence the contribution as families per household ― were undertaken in the informal settlement. The major findings are that households are generally motivated to implement energy saving strategies like covering pots when cooking, switching off lights in rooms that are not in use and that more information is needed as lack of knowledge and ‘landlord control' were identified as some of the barriers to energy

  14. Completely oriented anatase TiO2 nanoarrays: topotactic growth and orientation-related efficient photocatalysis

    Science.gov (United States)

    Yang, Jingling; Wu, Qili; He, Shiman; Yan, Jing; Shi, Jianying; Chen, Jian; Wu, Mingmei; Yang, Xianfeng

    2015-08-01

    A TiO2 film has been facilely grown on a Ti foil via a general and simple acid vapor oxidation (AVO) strategy. Based on detailed characterization by using X-ray diffraction (XRD), scanning electron microscopy (SEM) and transmission electron microscopy (TEM), we found that the TiO2 film was composed of anatase nanoarrays highly oriented along their direction, resulting in a large exposed {001} top surface on the film. The growth mechanism based on a topotactic transformation was proposed according to a careful study of time-dependent experimental results. Resulting from the evaluation of photocatalytic performance compared with a commercial TiO2 photocatalyst (Degussa P25), the as-prepared oriented anatase TiO2 film showed higher efficiency for degradation of atrazine and acid orange II (AOII). The performance of photocatalysis is highly relevant to the preferential orientation. The efficient photocatalysis could be attributed to the highly reactive {001} facets on the anatase nanoarrays with super-hydrophilicity.A TiO2 film has been facilely grown on a Ti foil via a general and simple acid vapor oxidation (AVO) strategy. Based on detailed characterization by using X-ray diffraction (XRD), scanning electron microscopy (SEM) and transmission electron microscopy (TEM), we found that the TiO2 film was composed of anatase nanoarrays highly oriented along their direction, resulting in a large exposed {001} top surface on the film. The growth mechanism based on a topotactic transformation was proposed according to a careful study of time-dependent experimental results. Resulting from the evaluation of photocatalytic performance compared with a commercial TiO2 photocatalyst (Degussa P25), the as-prepared oriented anatase TiO2 film showed higher efficiency for degradation of atrazine and acid orange II (AOII). The performance of photocatalysis is highly relevant to the preferential orientation. The efficient photocatalysis could be attributed to the highly reactive {001

  15. Objective evaluation of Tl-201 image efficacy for detection of myocardial infarction

    International Nuclear Information System (INIS)

    Nagai, Teruo; Murata, Kazuhiko; Torizuka, Kanji

    1982-01-01

    As the 3rd report of the objective analysis of radioactive 201 Tl scintigraphy of myocardial infarction, detection of infarction and extent of the lesion was discussed. In 114 cases with relatively definite findings, their images were rereaded and evaluated by 2 physicians. Segmental analysis in each direction was employed for localization of perfusion defects. Comparison between the sites of myocardial infarction on ECG and that of perfusion defects by segmental analysis revealed that, in infarction of the anterior wall, many segments showed defects, and that the lesions of the posterior and lateral wall had a few segments showing defects. This standard of correlation was applied to other cases of myocardial infarction, and the result suggested possible improvement in detection of infarction. As regards the extent of the lesion, no significant correlation between number of segments with defect and ECG and/or the serum enzyme levels were seen. (Ueda, J.)

  16. Zeroing of the TL signal of sediment undergoing fluvial transportation: a laboratory experiment

    International Nuclear Information System (INIS)

    Gemmell, A.M.D.

    1985-01-01

    Rates of bleaching of suspended sediment undergoing fluvial transportation in a closed laboratory flume beneath a u.v. lamp were measured. It was found that the speed of zeroing is inversely related to the speed of flow. This is attributed to the effects of flow turbulence in keeping sediment in suspension, thereby reducing the penetration of u.v. radiation, and to the re-entrainment of partially bleached or unbleached sediment into the flow. The time required to reduce TL to the residual levels indicated by sunlamp bleaching experiments are such as to suggest that at faster flows sediments in a heavily-laden stream may never attain a complete bleaching. (author)

  17. Applicability of a portable CdTe and NaI (Tl) spectrometer for activity measure

    International Nuclear Information System (INIS)

    Fernandes, Jaquiel Salvi

    2005-02-01

    In this work it was studied the application of an in situ gamma spectrometer (ROVER) of Amptek Inc., composed by a Cadmium Telluride detector (CdTe) of 3 mm x 3 mm x 1 mm and a 30 mm x 30 mm Sodium Iodide detector doped with Thallium [NaI (Tl)). The radioactive sources used were type pastille, sealed in aluminum and polyethylene, of 241 Am, 133 Ba, 152 Eu, 3 sources of 137 Cs and soil samples contaminated with 137 Cs. It was performed a factorial planning 2 3 to optimize the in situ spectrometry system. This way it was determined that the best temperature for CdTe crystal operation is -22, deg C, with Shaping Time of 3 μS and Rise Time Discrimination (RTD) with value 3. With the help of the certified radioactive sources, we determined the efficiency curve of the two detectors. The CdTe detector was positioned at the standard distance of 1 meter of the sources and also at 4.15 cm. The NaI (Tl) detector was also positioned at the standard distance of 1 meter of the sources and at 2.8 cm. Measures were performed to determine the Minimum Detectable Activity (MDA) for both detectors. For the pastille type sources, the 137 Cs MDA for the CdTe detector at 4.15 cm, analyzing the energy line of 32 keV, was 6 kBq and at 1 meter of the 137 Cs source, analyzing the line of 661.65 keV, the MDA was 67 kBq. For soil samples, CdTe detector at 4.15 cm presented a MDA of 693 kBq.kg-l for the line of 32 keV, and for the soil sample 7 Be content the MDA found was 2867 Bq.kg -1 at 4.15 cm. For the NaI (Tl) detector, analyzing the line of 661.65 keV, the 137 Cs MDA for pastille type source at 1 meter of distance was 7 kBq, and for soil sample at 2.8 cm the measured 137 Cs MDA was 71 Bq.kg -1 . For the soil sample 7 Be content, at 2.8 cm of the Nal (Tl) detector, the obtained MDA was 91 Bq.kg -1 . Due to the minimum detectable activities found for the two detectors, we concluded that the employed in situ gamma ray spectrometer system allows the quantification of 137 Cs and 7 Be

  18. Study of multi-quasiparticle band structures in 197Tl using α beam

    International Nuclear Information System (INIS)

    Mukherjee, G.; Nandi, S.; Pai, H.

    2016-01-01

    Study of the multi-quasiparticle (qp) states and the band structures built on them in the neutron deficient Tl nuclei in A ∼ 190 mass region provides useful information on particle-hole interaction in the heavy nuclei. In order to investigate the multi-qp band structures we have studied the excited states in 197 Tl by gamma ray spectroscopy

  19. On the Constitution of SoTL: Its Domains and Contexts

    Science.gov (United States)

    Booth, S.; Woollacott, L. C.

    2018-01-01

    In this paper, we present an analysis of the Scholarship of Teaching and Learning in Higher Education (SoTL) which contributes to SoTL both as a field of research practice and as a background to professional development in higher education. We analyse and describe the constitution of the field, and in so doing address its nature in the face of the…

  20. Enhanced thermoelectric figure of merit in strained Tl-doped Bi2Se3

    KAUST Repository

    Saeed, Y.; Singh, Nirpendra; Schwingenschlö gl, Udo

    2014-01-01

    We explain recent experimental findings on Tl-doped Bi2Se3 by determining the electronic and transport properties by first-principles calculations and semi-classical Boltzmann theory. Though Tl-doping introduces a momentum-dependent spin

  1. Identification of food preserved by ionizing radiation; Preliminary tests in strawberries using thermoluminescent (TL)

    International Nuclear Information System (INIS)

    Rubio, T.; Sillano, O.; Espinoza, J.; Roman, A.; Deza, A.

    1992-01-01

    TL measurements, of irradiated and unirradiated strawberries were carried out, using peel, seeds (achenes), leaves and sediment. The four types of samples presented a different thermoluminescence response. The best results were obtained with sediment removed from the soil of the fruit surface. It is concluded that TL is a promising technique for detecting irradiated strawberries using sediment samples. (author)

  2. Value of dipyridamole stress 201Tl myocardial SPECT in detecting dysfunction of coronary microcirculation

    International Nuclear Information System (INIS)

    Lou Ying; Jiang Jinqi; Xie Wenhui; Yuan Fang; Wang Tong; Yang Yiqing

    2012-01-01

    Objective: To evaluate the value of dipyridamole stress 201 Tl myocardial SPECT in detecting dysfunction of coronary microcirculation. Methods: Forty-eight patients diagnosed with cardiac syndrome X underwent dipyridamole stress 201 Tl myocardial SPECT. Dipyridamole (0.56 mg/kg) was intravenously injected over 4 min followed by 201 Tl (111 MBq) injection at 2 min after dipyridamole administration. Image was acquired at 10 min and 240 min post-injection and co-analyzed by over two experienced doctors in nuclear medicine after three-dimensional reconstruction. The patients with 'reverse redistribution' underwent repeated dipyridamole stress 201 Tl SPECT after medical therapy for 2 weeks. The clinical symptoms and results of the treadmill exercise test pre-and post-therapy were compared. Results: Forty two patients (42/48, 87.50%) showed segmental defects: 'reverse redistribution' on delayed (240 min) 201 Tl images. After medical treatment, 36 cases of the 42 'reverse redistribution' patients had improvement in both clinical symptoms and treadmill exercise test. Post-treatment 201 Tl imaging showed improvement in 45/49 (91.84%) defect segments. Six of the 42 patients had no improvement in clinical symptoms and/or treadmill exercise test. Post-treatment 201 Tl imaging showed no improvement in all the 7 defect segments on the first scan. Conclusion: Dipyridamole stress 201 Tl myocardial SPECT may be valuable in evaluation of impaired coronary microcirculation associated with cardiac syndrome X. (authors)

  3. Observation of curious spiral growth features in Tl doped Hg bearing ...

    Indian Academy of Sciences (India)

    Synthesis of H(Tl)Ba2Ca2Cu3O8+ superconducting tapes have been accomplished by annealing the precursor tape, Ba2Ca2Cu3O (fabricated by doctor blade tape casting technique) in an environment of H(Tl) vapour. Characterization of superconducting HTSC tape sample was carried out through XRD, TEM, SEM ...

  4. Pulse shaping for fast coincidence with NaI(Tl) detectors

    International Nuclear Information System (INIS)

    Bose, S.; Sinha, B.K.; Bhattacharya, R.

    1983-01-01

    The effect of multiple limiting of the anode pulses of the photomultiplier tubes on the resolving time of an NaI(Tl)-NaI(Tl) fast coincidence set up is investigated with the help of a simple transistored limiter circuit. The performance of the set up for different energy ranges selected in the side channels is also investigated. (orig.)

  5. TL and ESR based identification of gamma-irradiated frozen fish using different hydrolysis techniques

    International Nuclear Information System (INIS)

    Ahn, Jae-Jun; Akram, Kashif; Shahbaz, Hafiz Muhammad; Kwon, Joong-Ho

    2014-01-01

    Frozen fish fillets (walleye Pollack and Japanese Spanish mackerel) were selected as samples for irradiation (0–10 kGy) detection trials using different hydrolysis methods. Photostimulated luminescence (PSL)-based screening analysis for gamma-irradiated frozen fillets showed low sensitivity due to limited silicate mineral contents on the samples. Same limitations were found in the thermoluminescence (TL) analysis on mineral samples isolated by density separation method. However, acid (HCl) and alkali (KOH) hydrolysis methods were effective in getting enough minerals to carry out TL analysis, which was reconfirmed through the normalization step by calculating the TL ratios (TL 1 /TL 2 ). For improved electron spin resonance (ESR) analysis, alkali and enzyme (alcalase) hydrolysis methods were compared in separating minute-bone fractions. The enzymatic method provided more clear radiation-specific hydroxyapatite radicals than that of the alkaline method. Different hydrolysis methods could extend the application of TL and ESR techniques in identifying the irradiation history of frozen fish fillets. - Highlights: • Irradiation has potential to improve hygienic quality of raw and processed seafood. • Detection of irradiated food is important to enforce the applied regulations. • Different techniques were compared to separate silicate minerals from frozen fish. • Limitations were observed in TL analysis on minerals isolated by density separation. • Hydrolysis methods provided more clear identification using TL and ESR techniques

  6. The influence of relatives on the efficiency and error rate of familial searching.

    Directory of Open Access Journals (Sweden)

    Rori V Rohlfs

    Full Text Available We investigate the consequences of adopting the criteria used by the state of California, as described by Myers et al. (2011, for conducting familial searches. We carried out a simulation study of randomly generated profiles of related and unrelated individuals with 13-locus CODIS genotypes and YFiler® Y-chromosome haplotypes, on which the Myers protocol for relative identification was carried out. For Y-chromosome sharing first degree relatives, the Myers protocol has a high probability (80~99% of identifying their relationship. For unrelated individuals, there is a low probability that an unrelated person in the database will be identified as a first-degree relative. For more distant Y-haplotype sharing relatives (half-siblings, first cousins, half-first cousins or second cousins there is a substantial probability that the more distant relative will be incorrectly identified as a first-degree relative. For example, there is a 3~18% probability that a first cousin will be identified as a full sibling, with the probability depending on the population background. Although the California familial search policy is likely to identify a first degree relative if his profile is in the database, and it poses little risk of falsely identifying an unrelated individual in a database as a first-degree relative, there is a substantial risk of falsely identifying a more distant Y-haplotype sharing relative in the database as a first-degree relative, with the consequence that their immediate family may become the target for further investigation. This risk falls disproportionately on those ethnic groups that are currently overrepresented in state and federal databases.

  7. Innovations with services relating to energy efficiency. Basic information and examples; Innovationen mit Dienstleistungen im Bereich Energieeffizienz. Basisinformationen und Beispiele

    Energy Technology Data Exchange (ETDEWEB)

    Knoll, Michael; Kollnig, Sarah; Oertel, Britta

    2010-07-01

    This study describes how the ''Energy Efficient City'' competition is intended to promote activities towards greater energy efficiency which relate to cities as systems, are innovative, and conceive of and incorporate services as part of the solution. ''Innovation with services'' is not only about the further development of existing services but more particularly about the creation of high-quality services in growth areas which can serve to speed up innovation and create new application potentials for technical developments. They should be based on a holistic view on urban processes of energy use and energy supply and give consideration to all relevant stakeholders. The ''Energy Efficient City'' competition is aimed at systematically linking innovations with services to energy efficiency issues. The implementation of these goals will be facilitated by accompanying research. To this end the present text provides information on how services can be geared to energy efficiency.

  8. Natural gas and CO2 price variation: impact on the relative cost-efficiency of LNG and pipelines.

    Science.gov (United States)

    Ulvestad, Marte; Overland, Indra

    2012-06-01

    THIS ARTICLE DEVELOPS A FORMAL MODEL FOR COMPARING THE COST STRUCTURE OF THE TWO MAIN TRANSPORT OPTIONS FOR NATURAL GAS: liquefied natural gas (LNG) and pipelines. In particular, it evaluates how variations in the prices of natural gas and greenhouse gas emissions affect the relative cost-efficiency of these two options. Natural gas is often promoted as the most environmentally friendly of all fossil fuels, and LNG as a modern and efficient way of transporting it. Some research has been carried out into the local environmental impact of LNG facilities, but almost none into aspects related to climate change. This paper concludes that at current price levels for natural gas and CO 2 emissions the distance from field to consumer and the volume of natural gas transported are the main determinants of transport costs. The pricing of natural gas and greenhouse emissions influence the relative cost-efficiency of LNG and pipeline transport, but only to a limited degree at current price levels. Because more energy is required for the LNG process (especially for fuelling the liquefaction process) than for pipelines at distances below 9100 km, LNG is more exposed to variability in the price of natural gas and greenhouse gas emissions up to this distance. If the prices of natural gas and/or greenhouse gas emission rise dramatically in the future, this will affect the choice between pipelines and LNG. Such a price increase will be favourable for pipelines relative to LNG.

  9. Evaluation of myocardial damage and cardiac residual capacity by Tl-201 myocardial scintigraphy in valvular heart diseases

    International Nuclear Information System (INIS)

    Indo, Shunju

    1992-01-01

    This study was performed to clarify whether the extent-score (Ex-Score) calculated by Tl-201 myocardial scintigraphy is a reliable indicator of the severity of myocardial damage and cardiac residual capacity in valvular heart diseases. The subjects consisted of 38 patients (10 with aortic regurgitation (AR), 4 with aortic stenosis (AS), 13 with mitral regurgitation (MR) and 11 with mitral stenosis (MS)). Ex-Scores were significantly correlated with the severity of myocardial damage found in biopsied specimens obtained intraoperatively (correlation efficiency to Ex-Score with cell diameter in AR, % fibrosis in AR, cell diameter in AS, electron microscopic score in MR and % fibrosis in MS was 0.873, 0.734, 0.970, 0.913 and 0.659, respectively). Ex-Scores were also correlated with cardiac residual capacity determined by radioisotope angiography (correlation efficiency to Ex-Score with %Δ ejection fraction in AR, %Δ end-systolic volume in MR, %Δ end-diastolic volume in MS was -0.764, 0.790 and -0.763, respectively). These results suggest that the severity of myocardial damage and cardiac residual capacity can be estimated by Tl-201 myocardial scintigraphy (Ex-Score) in valvular heart diseases. (author)

  10. Evaluation of polymer-coated CsI:Tl as an alpha/beta pulse shape discriminating flow-cell

    International Nuclear Information System (INIS)

    Branton, S.D.; Fjeld, R.A.; DeVol, T.A.

    1996-01-01

    A pulse shape discriminating flow-cell radiation detection system constructed with polymer coated CsI:Tl was evaluated for simultaneous gross alpha/gross beta quantification. The CsI:TI scintillator was crushed and sieved to 63-90 μm particle size and microencapsulated with Parylene C to reduce its rate of dissolution. Averaged over the first hour of use, the pulse shape discrimination figure-of-merit was 1.4 and the detection efficiencies were 64.9 ± 5.7 %, 52.5 ± 4.5 % and 4.5 ± 0.2 % for 233 U, 90 Sr/ 90 Y and 14 C , respectively. The typical background count rate in the alpha and beta pulse shape window was 0.17 and 0.004 cps, respectively. The resultant minimum detectable activity for a 30 second count time was calculated to be 0.19 ± 0.01 Bq, 0.9 ± 0.1 Bq and 11.4 ± 0.6 Bq for 233 U, 90 Sr/ 90 Y and 14 C, respectively. Although the 3 μm thick microencapsulation reduced CsI:Tl dissolution, the detection efficiency declined by a factor of two after 4.8 hours while the pulse shape resolution degraded slightly

  11. A study of the effect of Al2O3 reflector on response function of NaI(Tl) detector

    International Nuclear Information System (INIS)

    Tam, Hoang Duc; Chuong, Huynh Dinh; Thanh, Tran Thien; Van Tao, Chau

    2016-01-01

    This study aims to assess the effect of Al 2 O 3 reflector surrounding the NaI(Tl) crystal on the detector response function, based on Monte Carlo simulation, which can verify the precise model of the NaI(Tl) detector. The method used in determining the suitable thickness of Al 2 O 3 reflector is to compare the calculated and experimental values of full-energy peak efficiency. The results show that the Al 2 O 3 reflector should have a thickness of 0.8–1.2 mm for the maximum deviation between the experimental and simulated efficiency of 3.2% at all concerning energies. In addition, the obtained results are in good agreement with the response function of simulation and experimental spectra. - Highlights: • The study was conducted to verify the model of Monte Carlo simulation. • The effect of Al 2 O 3 reflector on the detector response function was investigated. • The optimum thickness of Al 2 O 3 reflector is suggested.

  12. Comparison of Relative Bias, Precision, and Efficiency of Sampling Methods for Natural Enemies of Soybean Aphid (Hemiptera: Aphididae).

    Science.gov (United States)

    Bannerman, J A; Costamagna, A C; McCornack, B P; Ragsdale, D W

    2015-06-01

    Generalist natural enemies play an important role in controlling soybean aphid, Aphis glycines (Hemiptera: Aphididae), in North America. Several sampling methods are used to monitor natural enemy populations in soybean, but there has been little work investigating their relative bias, precision, and efficiency. We compare five sampling methods: quadrats, whole-plant counts, sweep-netting, walking transects, and yellow sticky cards to determine the most practical methods for sampling the three most prominent species, which included Harmonia axyridis (Pallas), Coccinella septempunctata L. (Coleoptera: Coccinellidae), and Orius insidiosus (Say) (Hemiptera: Anthocoridae). We show an important time by sampling method interaction indicated by diverging community similarities within and between sampling methods as the growing season progressed. Similarly, correlations between sampling methods for the three most abundant species over multiple time periods indicated differences in relative bias between sampling methods and suggests that bias is not consistent throughout the growing season, particularly for sticky cards and whole-plant samples. Furthermore, we show that sticky cards produce strongly biased capture rates relative to the other four sampling methods. Precision and efficiency differed between sampling methods and sticky cards produced the most precise (but highly biased) results for adult natural enemies, while walking transects and whole-plant counts were the most efficient methods for detecting coccinellids and O. insidiosus, respectively. Based on bias, precision, and efficiency considerations, the most practical sampling methods for monitoring in soybean include walking transects for coccinellid detection and whole-plant counts for detection of small predators like O. insidiosus. Sweep-netting and quadrat samples are also useful for some applications, when efficiency is not paramount. © The Authors 2015. Published by Oxford University Press on behalf of

  13. Stability of Tl-Ba-Ca-Cu-O superconducting thin films

    International Nuclear Information System (INIS)

    Siegal, M. P.; Overmyer, D. L.; Venturini, E. L.; Padilla, R. R.; Provencio, P. N.

    1999-01-01

    We report the stability of TlBa 2 CaCu 2 O 7 and Tl 2 Ba 2 CaCu 2 O 8 on LaAlO 3 (100) epitaxial thin films, under a variety of conditions. All films are stable in acetone and methanol and with repeated thermal cycling to cryogenic temperatures. Moisture, especially vapor, degrades film quality rapidly. These materials are stable to high temperatures in either N 2 or O 2 ambients. While total degradation, resulting from Tl depletion, occurs at the same temperatures for both phases, 600 degree sign C in N 2 and 700 degree sign C in O 2 , the onset of degradation occurs at somewhat lower temperatures for TlBa 2 CaCu 2 O 7 than for Tl 2 Ba 2 CaCu 2 O 8 . (c) 1999 Materials Research Society

  14. Synthesis and properties of Tl endash Ba endash Ca endash Cu endash O superconductors

    International Nuclear Information System (INIS)

    Siegal, M.P.; Venturini, E.L.; Morosin, B.; Aselage, T.L.

    1997-01-01

    We review the synthesis methods and properties of single crystal, powder and thin film TlBaCaCuO high-temperature superconducting (Tl-HTS) materials. With transition temperatures ≥100K for several compounds, Tl-HTS materials present real opportunities for applications above 77 K. Experiments using (1) single crystals: determined precise structural parameters and identified the complex Tl 1+ -Tl 3+ equilibrium model; (2) powders: studied the complex thermodynamic phase diagram; and (3) epitaxial films: have studied fundamental properties such as electron pair symmetry and the effect of controlled extrinsic defects on flux pinning strength, as well as providing the large-area surfaces required for device applications. copyright 1997 Materials Research Society

  15. Effects of smoking on lung uptake of 201Tl during exercise myocardial perfusion imaging

    International Nuclear Information System (INIS)

    Ouyang Wei; He Guorong; Liu Jinhua

    2004-01-01

    Objective: To investigate the influence of smoking on lung uptake of 201 Tl during myocardial perfusion imaging. Methods: Ninety-two healthy subjects, with normal 201 Tl myocardial perfusion imaging findings but no evidence of left ventricular hypertrophy and pulmonary disease, were divided into three groups, smoker, nonsmoker and quitted smoker groups. Exercise/delay 201 Tl myocardial perfusion imaging was performed on all subjects included. Lung/heart ratio was defined on the anterior planar image obtained during exercise tomography. Results: Both the lung/heart ratios during exercise in smoker (0.40 ± 0.07, F=10.635, P 201 Tl lung/heart ratios in smokers are higher than in nonsmokers and this must be kept in mind when 201 Tl lung/heart ratios are used clinically, even in quitted smokers

  16. A Call for Expanding Inclusive Student Engagement in SoTL

    Directory of Open Access Journals (Sweden)

    Peter Felten

    2013-09-01

    of student-faculty partnerships focused on inquiry into teaching and learning. However, some students tend to be privileged in SoTL initiatives while others are discouraged, implicitly or explicitly, from engaging in this work. In this paper, we consider why certain students tend to be excluded from SoTL, summarize the possible developmental gains made by students and faculty when diverse student voices are included, and highlight strategies for generating a more inclusive SoTL. We call for expanding student engagement in SoTL by encouraging a diversity of student voices to engage in co-inquiry with faculty. Inclusive engagement has tremendous potential to enhance student and faculty learning, to deepen SoTL initiatives, and to help redress the exclusionary practices that too often occur in higher education.

  17. Clinical application of 201Tl scintigraphy in patients with cold thyroid nodules

    International Nuclear Information System (INIS)

    Tonami, N.; Bunko, H.; Michigishi, T.; Kuwajima, A.; Hisada, K.

    1978-01-01

    201 Tl-chloride scintigraphy was performed in 45 patients with cold thyroid nodules. The 201 Tl scintigram was positive in 17 of 18 thyroid patients with cancer (94.4%), 8 of 20 patients with an adenoma (40.0%), 1 of 2 adenomatous goiter patients (50.5%), and all of 5 cases of chronic thyroiditis (100.0%). When the cold nodule was demonstrated to be positive with 201 Tl, the statistical chance of the lesion being a cellular one was 100.0% and a risk of its malignancy was 54.8%. On the other hand, the nodule with negative 201 Tl concentration had a 14.3% chance of cellularity and a 7.1% risk of malignancy. Thus, 201 Tl scintigraphy is of use in the differential diagnosis of the cold thyroid nodule

  18. Comparison of functional parameters of CsI:Tl crystals and thick films

    International Nuclear Information System (INIS)

    Fedorov, A.; Gektin, A.; Lebedynskiy, A.; Mateychenko, P.; Shkoropatenko, A.

    2013-01-01

    500 mkm thick CsI:Tl columnar films can be produced using thermal evaporation in vacuum by sublimation of the same bulk crystal. Comparison of afterglow and radiation stability of deposited CsI:Tl films with source crystal was the aim of current work. It is shown that the afterglow in the films is always below its level in initial single crystal. It was ascertained that the annealing atmospheres influence the processes leading to the activator depletion of the films during the thermal processing. -- Highlights: ► Thick CsI:Tl columnar films were obtained by thermal evaporation in vacuum. ► Radiation stability of such CsI:Tl films appears to be better than that of crystal. ► CsI:Tl film parameters can be modified by annealing in different atmospheres

  19. Multi-band Monopole Antennas Loaded with Metamaterial TL

    Science.gov (United States)

    Song, Zhi-jie; Liang, Jian-gang

    2015-05-01

    A novel metamaterial transmission line (TL) by loading complementary single Archimedean spiral resonator pair (CSASRP) is investigated and used to design a set of multi-frequency monopole antennas. The particularity is that the CSASRP which features dual-shunt branches in the equivalent circuit model is directly etched in the signal strip. By smartly controlling the element parameters, three antennas are designed and one of them covering UMTS and Bluetooth bands is fabricated and measured. The antenna exhibits impedance matching better than -10 dB and normal monopolar radiation patterns at working bands of 1.9-2.22 and 2.38-2.5 GHz. Moreover, the loaded element also contributes to the radiation, which is the major advantage of this prescription over previous lumped-element loadings. The proposed antenna is also more compact over previous designs.

  20. Superdeformed bands in Hg and Tl nuclei for N≤112

    International Nuclear Information System (INIS)

    Carpenter, M.P.; Jannsens, R.V.F.; Liang, Y.; Ahmad, I.; Henry, R.; Khoo, T.L.; Lauritsen, T.; Soramel, F.; Lewis, J.M.; Riedinger, L.L.; Yu, C.H.; Garg, U.; Reviol, W.; Pilotte, S.; Bearden, I.G.; Daly, P.J.

    1992-01-01

    The study of superdeformed (SD) nuclei in the A ∼ 190 region has provided a wealth of new information on SD states at moderate to high spins (I ∼ 10 to 50 h). The dynamical moment of inertia for almost all of the SD bands reported on to date in this mass region display a similar behavior, i.e. a smooth increase with increasing rotational frequency. This increase has been attributed to both quasiparticle alignments and a decrease in pairing with increasing rotational frequency. However, standard mean-field calculations have problems reproducing the magnitude and extent of the rise. The authors' recent results on SD states in the Hg-Tl nuclei at and below the N = 112 SD-gap add support to this interpretation of the rise in the dynamical moment of inertia while at the same time showing more clearly the inadequacies of the previous theoretical calculations

  1. Retrospective dosimetry using EPR and TL techniques: a status report

    International Nuclear Information System (INIS)

    Haskell, E.H.

    1996-01-01

    Methods of retrospective dosimetry, including luminescence and electron paramagnetic resonance spectroscopy (EPR), rely on measurement of accident dose absorbed by naturally occurring materials - ceramics in the case of both thermoluminescence (TL) and optically stimulated luminescence (OSL) and organic materials and bio- minerals in the case of EPR. Each of these methods relies on measurement of radiation defects resulting from accidental exposure. Since defects also result from natural sources of radiation over the lifetime of a sample, analysis is usually restricted to materials for which the natural dose may be determined and subtracted from the measured cumulative dose. Luminescence dating techniques rely heavily on an accurate assessment of cumulative dose from natural radiation sources, and dating research has provided us with the bulk of our knowledge in this area. Virtually all of the work on natural dose determination can be directly applied to retrospective techniques. With EPR techniques the cumulative dose from diagnostic x- rays is also of importance

  2. A new type of spurious reading in TL personnel monitoring

    International Nuclear Information System (INIS)

    Duftschmid, K.E.; Stadtmann, H.; Strachotinsky, Ch.; Winker, N.

    1996-01-01

    A particularly serious type of spurious reading in automated TL personnel monitoring has been observed. These readings simulate dose values up to several mSv and can only be detected by glow curve analysis. Characteristics for these events are high artifical dose values and irregular glow curves of a particular shape. Extensive investigations to reproduce this effect purposely failed to produce any results. It can be assumed, however, that it must be some chemical surface contamination, which penetrates the sealed dosemeter bag or which is transferred from the bag to the detector. The effect can be eliminated by manual cleaning of the dosemeter cards. The importance of this observation lies in the fact that only proper glow curve evaluation can prevent the monitoring service from reporting artificial high dose readings creating lots of serious problems. The paper shows how this problem can be avoided for this kind of spurious effect, if glow curves are available and stored for every dosemeter readout. (author)

  3. Giant Rashba spin splitting in Bi2Se3: Tl

    KAUST Repository

    Singh, Nirpendra

    2014-07-25

    First-principles calculations are employed to demonstrate a giant Rashba spin splitting in Bi2Se3:Tl. Biaxial tensile and compressive strain is used to tune the splitting by modifying the potential gradient. The band gap is found to increase under compression and decreases under tension, whereas the dependence of the Rashba spin splitting on the strain is the opposite. Large values of αR = 1.57 eV Å at the bottom of the conduction band (electrons) and αR = 3.34 eV Å at the top of the valence band (holes) are obtained without strain. These values can be further enhanced to αR = 1.83 eV Å and αR = 3.64 eV Å, respectively, by 2% tensile strain. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. Core excitations across the neutron shell gap in 207Tl

    Directory of Open Access Journals (Sweden)

    E. Wilson

    2015-07-01

    Full Text Available The single closed-neutron-shell, one proton–hole nucleus 207Tl was populated in deep-inelastic collisions of a 208Pb beam with a 208Pb target. The yrast and near-yrast level scheme has been established up to high excitation energy, comprising an octupole phonon state and a large number of core excited states. Based on shell-model calculations, all observed single core excitations were established to arise from the breaking of the N=126 neutron core. While the shell-model calculations correctly predict the ordering of these states, their energies are compressed at high spins. It is concluded that this compression is an intrinsic feature of shell-model calculations using two-body matrix elements developed for the description of two-body states, and that multiple core excitations need to be considered in order to accurately calculate the energy spacings of the predominantly three-quasiparticle states.

  5. Retrospective dosimetry using EPR and TL techniques: a status report

    Energy Technology Data Exchange (ETDEWEB)

    Haskell, E.H.

    1996-12-31

    Methods of retrospective dosimetry, including luminescence and electron paramagnetic resonance spectroscopy (EPR), rely on measurement of accident dose absorbed by naturally occurring materials - ceramics in the case of both thermoluminescence (TL) and optically stimulated luminescence (OSL) and organic materials and bio- minerals in the case of EPR. Each of these methods relies on measurement of radiation defects resulting from accidental exposure. Since defects also result from natural sources of radiation over the lifetime of a sample, analysis is usually restricted to materials for which the natural dose may be determined and subtracted from the measured cumulative dose. Luminescence dating techniques rely heavily on an accurate assessment of cumulative dose from natural radiation sources, and dating research has provided us with the bulk of our knowledge in this area. Virtually all of the work on natural dose determination can be directly applied to retrospective techniques. With EPR techniques the cumulative dose from diagnostic x- rays is also of importance.

  6. Efficiency correction for disk sources using coaxial High-Purity Ge detectors

    International Nuclear Information System (INIS)

    Chatani, Hiroshi.

    1993-03-01

    Efficiency correction factors for disk sources were determined by making use of closed-ended coaxial High-Purity Ge (HPGe) detectors, their relative efficiencies for a 3' 'x3' ' NaI(Tl) with the 1.3 MeV γ-rays were 30 % and 10 %, respectively. Parameters for the correction by mapping method were obtained systematically, using several monoenergetic (i.e. no coincidence summing loses) γ-ray sources produced by irradiation in the Kyoto University Reactor (KUR) core. These were found out that (1) the systematics of the Gaussian fitting parameters, which were calculated using the relative efficiency distributions of HPGe, to the γ-ray energies are recognized, (2) the efficiency distributions deviate from the Gaussian distributions outside of the radii of HPGe. (3) mapping method is a practical use in satisfactory accuracy, as the results in comparison with the disk source measurements. (author)

  7. Metabolic efficiency in yeast Saccharomyces cerevisiae in relation to temperature dependent growth and biomass yield.

    Science.gov (United States)

    Zakhartsev, Maksim; Yang, Xuelian; Reuss, Matthias; Pörtner, Hans Otto

    2015-08-01

    Canonized view on temperature effects on growth rate of microorganisms is based on assumption of protein denaturation, which is not confirmed experimentally so far. We develop an alternative concept, which is based on view that limits of thermal tolerance are based on imbalance of cellular energy allocation. Therefore, we investigated growth suppression of yeast Saccharomyces cerevisiae in the supraoptimal temperature range (30-40°C), i.e. above optimal temperature (Topt). The maximal specific growth rate (μmax) of biomass, its concentration and yield on glucose (Yx/glc) were measured across the whole thermal window (5-40°C) of the yeast in batch anaerobic growth on glucose. Specific rate of glucose consumption, specific rate of glucose consumption for maintenance (mglc), true biomass yield on glucose (Yx/glc(true)), fractional conservation of substrate carbon in product and ATP yield on glucose (Yatp/glc) were estimated from the experimental data. There was a negative linear relationship between ATP, ADP and AMP concentrations and specific growth rate at any growth conditions, whilst the energy charge was always high (~0.83). There were two temperature regions where mglc differed 12-fold, which points to the existence of a 'low' (within 5-31°C) and a 'high' (within 33-40°C) metabolic mode regarding maintenance requirements. The rise from the low to high mode occurred at 31-32°C in step-wise manner and it was accompanied with onset of suppression of μmax. High mglc at supraoptimal temperatures indicates a significant reduction of scope for growth, due to high maintenance cost. Analysis of temperature dependencies of product formation efficiency and Yatp/glc revealed that the efficiency of energy metabolism approaches its lower limit at 26-31°C. This limit is reflected in the predetermined combination of Yx/glc(true), elemental biomass composition and degree of reduction of the growth substrate. Approaching the limit implies a reduction of the safety margin

  8. Teaching the relation between solar cell efficiency and annual energy yield

    International Nuclear Information System (INIS)

    Sark, Wilfried G J H M van

    2007-01-01

    To reach a sustainable world the use of renewable energy sources is imperative. Photovoltaics (PV) is but one of the technologies that use the power of the sun and its deployment is growing very fast. Several master programs have been developed over the world, including Utrecht University, that teach these technologies. Within the framework of a course on energy conversion technologies, we have developed a classroom problem that focuses on the difference between PV efficiency and annual yield for the two locations: the Utrecht University campus and the African Sahara desert. In spreadsheet format, students calculate annual yield, and they find a best method to do so. The exercise can be done in about three hours, and students will learn that the annual yield in the Sahara is only twice that at Utrecht University,

  9. Extremely efficient crystallization of HKUST-1 and Keggin-loaded related phases through the epoxide route.

    Science.gov (United States)

    Oestreicher, Víctor; Jobbágy, Matías

    2017-03-25

    Highly crystalline HKUST-1 and COK-16-like phases were obtained based on a mild in situ alkalinization one-pot epoxide driven method. A slurry composed of finely ground trimesic acid, H 3 BTC, dispersed in a CuCl 2 aqueous solution quantitatively developed well crystallized HKUST-1 after the addition of propylene oxide. The use of solid H 3 BTC ensures a low concentration of free linker, favoring crystalline growth over the precipitation of amorphous or metastable impurities. An extreme space-time yield of 2.1 × 10 5 kg m -3 day -1 was reached, with no linker excess and minimum use of solvent. The method was equally efficient in the achievement of pure NENU/COK-16 phases, containing [PW 12 O 40 ] 3- , [PMo 12 O 40 ] 3- and [SiMo 12 O 40 ] 4- polyoxometalates.

  10. Energy-Efficient Management of Mechanical Ventilation and Relative Humidity in Hot-Humid Climates

    Energy Technology Data Exchange (ETDEWEB)

    Withers, Jr., Charles R. [Building America Partnership for Improved Residential Construction, Cocoa, FL (United States)

    2016-12-01

    In hot and humid climates, it is challenging to energy-efficiently maintain indoor RH at acceptable levels while simultaneously providing required ventilation, particularly in high performance low cooling load homes. The fundamental problem with solely relying on fixed capacity central cooling systems to manage moisture during low sensible load periods is that they are oversized for cooler periods of the year despite being 'properly sized' for a very hot design cooling day. The primary goals of this project were to determine the impact of supplementing a central space conditioning system with 1) a supplemental dehumidifier and 2) a ductless mini-split on seasonal energy use and summer peak power use as well as the impact on thermal distribution and humidity control inside a completely furnished lab home that was continuously ventilated in accordance with ASHRAE 62.2-2013.

  11. Variability of photovoltaic panels efficiency depending on the value of the angle of their inclination relative to the horizon

    OpenAIRE

    Majdak Marek

    2017-01-01

    The objective of this paper was to determine the relationship between the efficiency of photovoltaic panels and the value of the angle of their inclination relative to the horizon. For the purpose of experimental research have been done tests on the photovoltaic modules made of monocrystalline, polycrystalline and amorphous silicon. The experiment consisted of measurement of the voltage and current generated by photovoltaic panels at a known value of solar radiation and a specified resistance...

  12. CsI(Tl) with photodiodes for identifying subsurface radionuclide contamination

    International Nuclear Information System (INIS)

    Stromswold, D.C.; Meisner, J.E.; Nicaise, W.F.

    1994-10-01

    At the US Department of Energy's Hanford Site near Richland, Washington, underground radioactive contamination exists as the result of leaks, spills, and intentional disposal of waste products from plutonium-production operations. Characterizing these contaminants in preparation for environmental remediation is a major effort now in progress. In this paper, a cylindrical (15 x 61 mm) CsI(Tl) scintillation detector with two side-mounted photodiodes has been developed to collect spectral gamma-ray data in subsurface contaminated formations at the U.S. Department of Energy's Hanford Site. It operates inside small-diameter, thick-wall steel pipes pushed into the ground to depths up to 20 m by a cone penetrometer. The detector provides a rugged, efficient, magnetic-field-insensitive means for identifying gamma-ray-emitting contaminants (mainly 137 Cs and 60 Co). Mounting two 3 x 30-mm photodiodes end-to-end on a flat area along the detector's side provides efficient light collection over the length of the detector

  13. The study of error for analysis in dynamic image from the error of count rates in Nal (Tl) scintillation camera

    International Nuclear Information System (INIS)

    Oh, Joo Young; Kang, Chun Goo; Kim, Jung Yul; Oh, Ki Baek; Kim, Jae Sam; Park, Hoon Hee

    2013-01-01

    This study is aimed to evaluate the effect of T 1/2 upon count rates in the analysis of dynamic scan using NaI (Tl) scintillation camera, and suggest a new quality control method with this effects. We producted a point source with '9 9m TcO 4 - of 18.5 to 185 MBq in the 2 mL syringes, and acquired 30 frames of dynamic images with 10 to 60 seconds each using Infinia gamma camera (GE, USA). In the second experiment, 90 frames of dynamic images were acquired from 74 MBq point source by 5 gamma cameras (Infinia 2, Forte 2, Argus 1). There were not significant differences in average count rates of the sources with 18.5 to 92.5 MBq in the analysis of 10 to 60 seconds/frame with 10 seconds interval in the first experiment (p>0.05). But there were significantly low average count rates with the sources over 111 MBq activity at 60 seconds/frame (p<0.01). According to the second analysis results of linear regression by count rates of 5 gamma cameras those were acquired during 90 minutes, counting efficiency of fourth gamma camera was most low as 0.0064%, and gradient and coefficient of variation was high as 0.0042 and 0.229 each. We could not find abnormal fluctuation in χ 2 test with count rates (p>0.02), and we could find the homogeneity of variance in Levene's F-test among the gamma cameras (p>0.05). At the correlation analysis, there was only correlation between counting efficiency and gradient as significant negative correlation (r=-0.90, p<0.05). Lastly, according to the results of calculation of T 1/2 error from change of gradient with -0.25% to +0.25%, if T 1/2 is relatively long, or gradient is high, the error increase relationally. When estimate the value of 4th camera which has highest gradient from the above mentioned result, we could not see T 1/2 error within 60 minutes at that value. In conclusion, it is necessary for the scintillation gamma camera in medical field to manage hard for the quality of radiation measurement. Especially, we found a

  14. The effect of right ventricular pacing on myocardial oxidative metabolism and efficiency: relation with left ventricular dyssynchrony

    Energy Technology Data Exchange (ETDEWEB)

    Ukkonen, Heikki; Saraste, Antti; Koistinen, Juhani [Turku University Hospital, Department of Medicine, P.O. Box 52, Turku (Finland); Tops, Laurens; Bax, Jeroen [Leiden University Medical Center, Leiden (Netherlands); Naum, Alexander [University of Turku, Turku PET Centre, Turku (Finland); Knuuti, Juhani [University of Turku, Turku PET Centre, Turku (Finland); Turku University Hospital, Turku PET Centre, P.O. Box 52, Turku (Finland)

    2009-12-15

    Right ventricular (RV) apical pacing induces dyssynchrony by a left bundle branch block type electrical activation sequence in the heart and may impair left ventricular (LV) function. Whether these functional changes are accompanied by changes in myocardial perfusion, oxidative metabolism and efficiency, and the relation with the induction of LV dyssynchrony are unknown. Our study was designed to investigate the acute effects of RV pacing on these parameters. Ten patients with normal LV ejection fraction and VVI/DDD pacemaker were studied during AAI pacing/sinus rhythm without RV pacing (pacing-OFF) and with RV pacing (pacing-ON) at the same heart rate. Dynamic [{sup 15}O]water and [{sup 11}C]acetate positron emission tomography was used to measure perfusion and oxidative metabolism (k{sub mono}) of the LV. An echocardiographic examination was used to assess LV stroke volume (SV) and LV dyssynchrony. Myocardial efficiency of forward work was calculated as systolic blood pressure x cardiac output/LV mass/k{sub mono}. RV pacing decreased SV in all subjects (mean decrease 13%, from 76 {+-} 7 to 66 {+-} 7 ml, p = 0.004), but global perfusion and k{sub mono} were unchanged. The efficiency tended to be lower with pacing-ON (70 {+-} 20 vs 81 {+-} 21 mmHg l/g, p = 0.066). In patients with dyssynchrony during pacing (n = 6) efficiency decreased by 23% (from 78 {+-} 25 to 60 {+-} 14 mmHg l/g, p = 0.02), but in patients without dyssynchrony no change in efficiency was detected. Accordingly, heterogeneity in myocardial perfusion and oxidative metabolism was detected during pacing in patients with dyssynchrony but not in those without dyssynchrony. RV pacing resulted in a significant decrease in SV. However, deleterious effects on LV oxidative metabolism and efficiency were observed only in patients with dyssynchrony during RV pacing. (orig.)

  15. [Catheter-related bladder discomfort after urological surgery: importance of the type of surgery and efficiency of treatment by clonazepam].

    Science.gov (United States)

    Maro, S; Zarattin, D; Baron, T; Bourez, S; de la Taille, A; Salomon, L

    2014-09-01

    Bladder catheter can induce a Catheter-Related Bladder Discomfort (CRBD). Antagonist of muscarinic receptor is the gold standard treatment. Clonazepam is an antimuscarinic, muscle relaxing oral drug. The aim of this study is to look for a correlation between the type of surgical procedure and the existence of CRBD and to evaluate the efficiency of clonazepam. One hundred patients needing bladder catheter were evaluated. Sexe, age, BMI, presence of diabetes, surgical procedure and existence of CRBD were noted. Pain was evaluated with analogic visual scale. Timing of pain, need for specific treatment by clonazepam and its efficiency were noted. Correlation between preoperative data, type of surgical procedure, existence of CRBD and efficiency of treatment were evaluated. There were 79 men and 21 women (age: 65.9 years, BMI: 25.4). Twelve patients presented diabetes. Surgical procedure concerned prostate in 39 cases, bladder in 19 cases (tumor resections), endo-urology in 20 cases, upper urinary tract in 12 cases (nephrectomy…) and lower urinary tract in 10 cases (sphincter, sub-uretral tape). Forty patients presented CRBD, (pain 4.5 using VAS). This pain occurred 0.6 days after surgery. No correlation was found between preoperative data and CRBD. Bladder resection and endo-urological procedures were surgical procedures which procured CRBD. Clonazepam was efficient in 30 (75 %) out of 40 patients with CRBD. However, it was less efficient in case of bladder tumor resection. CRBD is frequent and occurred immediately after surgery. Bladder resection and endo-urology were the main surgical procedures which induced CRBD. Clonazepam is efficient in 75 %. Bladder resection is the surgical procedure which is the most refractory to treatment. 5. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  16. Mismatched regional myocardial uptake between [sup 123]I-BMIPP and [sup 201]Tl SPECT; Comparison between hypertrophic myocardium and dilated myocardium

    Energy Technology Data Exchange (ETDEWEB)

    Otsuka, Makoto; Ichiya, Yuichi; Kuwabara, Yasuo; Sasaki, Masayuki; Fukumura, Toshimitsu; Masuda, Kouji; Ejima, Junichi; Tsuda, Yasuo (Kyushu Univ., Fukuoka (Japan). Faculty of Medicine)

    1992-07-01

    The distribution of a new myocardial fatty acid metabolic agent [sup 123]I-BMIPP was compared in 6 each patients with hypertrophic myocardium (4 cases of hypertensive heart disease and 2 of hypertrophic cardiomyopathy) and dilated myocardium (4 of dilated type of valvular heart disease and 2 of dilated cardiomyopathy) with that of [sup 201]Tl. Mismatched regional myocardial uptake between [sup 123]I-BMIPP and [sup 201]Tl SPECT was observed in all of the hypertrophic myocardium, however no but one in the dilated myocardium. Relative increase or decrease in regional BMIPP from the images of 20 min and to those of 4 h was observed in 3 cases of the hypertrophic myocardium. FDG-PET was performed in 2 cases of the hypertrophic myocardium. The distribution of FDG was different from neither those of BMIPP nor Tl in a hypertrophic cardiomyopathy case with the reserved distribution of BMIPP and Tl. Although more investigations are necessary, we concluded that [sup 123]I-BMIPP is a promising radiopharmaceutical for evaluating myocardial fatty acid metabolism in hypertrophic myocardium. (author).

  17. The effect of the downturn in oil prices on the relative efficiency of government expenditure in the GCC countries

    International Nuclear Information System (INIS)

    Metwally, M.M.; Perera, N.

    1995-01-01

    This paper tests a control model to discover the effect of the decline in oil prices on the relative efficiency of government expenditure in the member states of the Gulf Cooperation Council. The econometric analysis shows that as a consequence of the decline in oil prices, the GCC countries need a relatively higher proportional rate of growth in their government expenditure to maintain a given percentage of income growth in the long run. This may, however, prove difficult, which necessitates greater reliance on other means of control. (author)

  18. Variability of photovoltaic panels efficiency depending on the value of the angle of their inclination relative to the horizon

    Directory of Open Access Journals (Sweden)

    Majdak Marek

    2017-01-01

    Full Text Available The objective of this paper was to determine the relationship between the efficiency of photovoltaic panels and the value of the angle of their inclination relative to the horizon. For the purpose of experimental research have been done tests on the photovoltaic modules made of monocrystalline, polycrystalline and amorphous silicon. The experiment consisted of measurement of the voltage and current generated by photovoltaic panels at a known value of solar radiation and a specified resistance value determined by using resistor with variable value of resistance and known value of the angle of their inclination relative to the horizon.

  19. Energy-Efficient Hosting Rich Content from Mobile Platforms with Relative Proximity Sensing.

    Science.gov (United States)

    Park, Ki-Woong; Lee, Younho; Baek, Sung Hoon

    2017-08-08

    In this paper, we present a tiny networked mobile platform, termed Tiny-Web-Thing ( T-Wing ), which allows the sharing of data-intensive content among objects in cyber physical systems. The object includes mobile platforms like a smartphone, and Internet of Things (IoT) platforms for Human-to-Human (H2H), Human-to-Machine (H2M), Machine-to-Human (M2H), and Machine-to-Machine (M2M) communications. T-Wing makes it possible to host rich web content directly on their objects, which nearby objects can access instantaneously. Using a new mechanism that allows the Wi-Fi interface of the object to be turned on purely on-demand, T-Wing achieves very high energy efficiency. We have implemented T-Wing on an embedded board, and present evaluation results from our testbed. From the evaluation result of T-Wing , we compare our system against alternative approaches to implement this functionality using only the cellular or Wi-Fi (but not both), and show that in typical usage, T-Wing consumes less than 15× the energy and is faster by an order of magnitude.

  20. Variation in water-use efficiency and its relation to carbon isotope ratio in cotton

    International Nuclear Information System (INIS)

    Saranga, Y.; Flash, I.; Yakir, D.

    1998-01-01

    Cotton (Gossypium spp.) is often exposed to drought, which adversely affects both yield and quality. Improved water-use efficiency (WUE = total dry matter produced or yield harvested / water used) is expected to reduce these adverse effects. Genetic variability in WUE and its association with photosynthetic rate and carbon isotope ratio (13C/12C) in cotton are reported in this paper. WUE of six cotton cultivars--G. hirsutum L., G. barbadense L., and an interspecific F1 hybrid (G. hirsutum x G. barbadense, ISH), was examined under two irrigation regimes in two field trials. The greatest WUE was obtained by two G. hirsutum cultivars (2.55 g dry matter or 1.12 g seed-cotton L-1 H2O) the ISH obtained similar or somewhat lower values, and that G. barbadense cultivars and one G. hirsutum cultivar exhibited the lowest values (2.1 g dry matter or 0.8 to 0.85 g seed-cotton L-1 H2O). These results indicate that different cotton cultivars may have evolved different environmental adaptations that affect their WUE. Photosynthetic rate was correlated with WUE in only a few cases emphasizing the limitation of this parameter as a basis for estimating crop WUE. Under both trials WUE was positively correlated with carbon isotope ratio, indicating the potential of this technique as a selection criterion for improving cotton WUE