WorldWideScience

Sample records for relative tl efficiencies

  1. Alpha efficiency under TL and OSL - A subtraction technique using OSL and TL to detect artificial irradiation

    International Nuclear Information System (INIS)

    Zink, A.J.C.; Dabis, S.; Porto, E.; Castaing, J.

    2010-01-01

    With the development of thermoluminescence (TL) and optically stimulated luminescence (OSL) to determine the authenticity of old ceramics, forgers use artificial irradiation by gamma ray to age modern productions. Besides fraudulent action, objects can be exposed to various sources of X-rays (e.g. radiography, security control at airports). For all these reasons, the determination of artificial irradiation is an important topic for dating art objects. The main technique to identify artificial irradiations is the subtraction technique. It is based on the fact that alpha efficiency varies according to the luminescence technique (fine grain, coarse grains, predose, OSL). Having observed a rather significant difference of alpha efficiency for TL and OSL, we propose a new subtraction technique using OSL and TL of fine grains.

  2. Calculation of the relative efficiency of thermoluminescent detectors to space radiation

    International Nuclear Information System (INIS)

    Bilski, P.

    2011-01-01

    Thermoluminescent (TL) detectors are often used for measurements of radiation doses in space. While space radiation is composed of a mixture of heavy charged particles, the relative TL efficiency depends on ionization density. The question therefore arises: what is the relative efficiency of TLDs to the radiation present in space? In the attempt to answer this question, the relative TL efficiency of two types of lithium fluoride detectors for space radiation has been calculated, based on the theoretical space spectra and the experimental values of TL efficiency to ion beams. The TL efficiency of LiF:Mg,Ti detectors for radiation encountered at typical low-Earth’s orbit was found to be close to unity, justifying a common application of these TLDs to space dosimetry. The TL efficiency of LiF:Mg,Cu,P detectors is significantly lower. It was found that a shielding may have a significant influence on the relative response of TLDs, due to changes caused in the radiation spectrum. In case of application of TLDs outside the Earth’s magnetosphere, one should expect lower relative efficiency than at the low-Earth’s orbit.

  3. T-L Plane Abstraction-Based Energy-Efficient Real-Time Scheduling for Multi-Core Wireless Sensors

    Directory of Open Access Journals (Sweden)

    Youngmin Kim

    2016-07-01

    Full Text Available Energy efficiency is considered as a critical requirement for wireless sensor networks. As more wireless sensor nodes are equipped with multi-cores, there are emerging needs for energy-efficient real-time scheduling algorithms. The T-L plane-based scheme is known to be an optimal global scheduling technique for periodic real-time tasks on multi-cores. Unfortunately, there has been a scarcity of studies on extending T-L plane-based scheduling algorithms to exploit energy-saving techniques. In this paper, we propose a new T-L plane-based algorithm enabling energy-efficient real-time scheduling on multi-core sensor nodes with dynamic power management (DPM. Our approach addresses the overhead of processor mode transitions and reduces fragmentations of the idle time, which are inherent in T-L plane-based algorithms. Our experimental results show the effectiveness of the proposed algorithm compared to other energy-aware scheduling methods on T-L plane abstraction.

  4. Determination of the full energy peak efficiency of NaI(Tl) detectors

    International Nuclear Information System (INIS)

    Cesana, A.; Terrani, M.

    1978-01-01

    A simple procedure for the accurate evaluation of the full energy peak efficiency of NaI(Tl) crystals is described. Particular attention is given to the peak to total ratio determination for which a new method is proposed. (author)

  5. Simulation of the peak efficiency for a stacked NaI(Tl) spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Yoshida, H; Murohka, H; Anami, K; Nohtomi, A; Uozumi, Y; Sakae, T; Matoba, M [Kyushu Univ., Fukuoka (Japan). Faculty of Engineering; Koori, N; Maki, T

    1996-07-01

    A stacked NaI(Tl) spectrometer has been developed to measure proton spectra in wide energy range. In the measurement of charged particles with intermediate energy, the detecting efficiency of the spectrometer decreases considerably due to nuclear reactions or out-scattering in the detector material. A Monte Carlo simulation code has been developed to estimate the peak efficiency (peak-to-total ratio) of the spectrometer. The calculated efficiency for intermediate energy is in good agreement with the experimental one. (author)

  6. Exploration of GaInTlP and related Tl-containing III-V alloys for photovoltaics

    International Nuclear Information System (INIS)

    Friedman, D. J.; Kurtz, Sarah R.; Kibbler, A. E.

    1999-01-01

    This paper discusses the results of an attempt to grow GaInTlP for application as a 1-eV material for the third junction of a GaInP/GaAs/3rd-junction high-efficiency solar cell. Although early indications from the literature were promising, we are unable to produce crystalline homogeneous material, and so we conclude that this material is not a promising candidate for such applications as photovoltaics

  7. Activation energies from blue- and red-thermoluminescence (TL) of quartz grains and mean lives of trapped electrons related to natural red-TL

    International Nuclear Information System (INIS)

    Hashimoto, T.; Kojima, M.; Shirai, N.; Ichino, M.

    1993-01-01

    A three-dimensional representation of thermoluminescence (TL) spectra has been established by employing an image intensifier unit combined with a simple spectrophotometer and a microcomputer. By means of this TL spectrometric system, natural quartz grains could be distinguished as either blue-and/or red-TL ones. In these blue- and red-TL wavelength regions, activation energies from artificially irradiated quartz grains are evaluated using a repeated initial rise method. An apparent difference of activation energies in the two colorations was observed for dune sands presumably originating from different quartz sources. On the other hand, quartz grains extracted from a volcanic ash sediment showed completely similar activation energies in both TL color regions over all temperatures. Subsequently, the kinetic parameters were derived for the naturally occurring red-TL, possessing an apparent single peak around 340 o C, from volcanically originating quartz grains by fitting a theoretical equation to the glow curves, after evaluating activation energies. On the basis of the empirical kinetic parameters, the mean life of trapped electrons relating to a main 340 o C peak has been proved to be 1 million years, and a secondary weak peak around 280 o C in the natural red-TL glow curve has been confirmed. (author)

  8. Spectral measurements of loess TL

    International Nuclear Information System (INIS)

    Rendell, H.M.; Mann, S.J.; Townsend, P.D.

    1988-01-01

    Variations in thermoluminescence (TL) glow curves are reported for two loess samples when examined with broad band filters in the range 275-650 nm. Samples show striking differences in bleaching behaviour, when their TL emissions are observed in the u.v., blue, green and yellow spectral regions. The age estimates, given by the equivalent dose (ED) values, differ by up to a factor of two for analyses using the green and u.v. TL signals. These ED values also vary with prolonged room temperature storage between the bleaching and irradiation steps. The anomalies in the bleaching behaviour are interpreted in terms of changes in TL efficiency. The results have major implications for the regeneration method of TL dating for these fine-grained sediments and suggest that reliable dates obtained by it may be fortuitous. (author)

  9. Scintillation efficiency measurement of Na recoils in NaI(Tl) below the DAMA/LIBRA energy threshold

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Jingke; Shields, Emily; Calaprice, Frank; Westerdale, Shawn; Froborg, Francis; Suerfu, Burkhant; Alexander, Thomas; Aprahamian, Ani; Back, Henning O.; Casarella, Clark; Fang, Xiao; Gupta, Yogesh K.; Ianni, Aldo; Lamere, Edward; Lippincott, W. Hugh; Liu, Qian; Lyons, Stephanie; Siegl, Kevin; Smith, Mallory; Tan, Wanpeng; Kolk, Bryant Vande

    2015-07-01

    The dark matter interpretation of the DAMA modulation signal depends on the NaI(Tl) scintillation efficiency of nuclear recoils. Previous measurements for Na recoils have large discrepancies, especially in the DAMA/LIBRA modulation energy region. We report a quenching effect measurement of Na recoils in NaI(Tl) from 3 to 52 keVnr, covering the whole DAMA/LIBRA energy region for dark matter-Na scattering interpretations. By using a low-energy, pulsed neutron beam, a double time-of-flight technique, and pulse-shape discrimination methods, we obtained the most accurate measurement of this kind for NaI(Tl) to date. The results differ significantly from the DAMA reported values at low energies but fall between the other previous measurements. We present the implications of the new quenching results for the dark matter interpretation of the DAMA modulation signal.

  10. Regional analysis of annual maximum rainfall using TL-moments method

    Science.gov (United States)

    Shabri, Ani Bin; Daud, Zalina Mohd; Ariff, Noratiqah Mohd

    2011-06-01

    Information related to distributions of rainfall amounts are of great importance for designs of water-related structures. One of the concerns of hydrologists and engineers is the probability distribution for modeling of regional data. In this study, a novel approach to regional frequency analysis using L-moments is revisited. Subsequently, an alternative regional frequency analysis using the TL-moments method is employed. The results from both methods were then compared. The analysis was based on daily annual maximum rainfall data from 40 stations in Selangor Malaysia. TL-moments for the generalized extreme value (GEV) and generalized logistic (GLO) distributions were derived and used to develop the regional frequency analysis procedure. TL-moment ratio diagram and Z-test were employed in determining the best-fit distribution. Comparison between the two approaches showed that the L-moments and TL-moments produced equivalent results. GLO and GEV distributions were identified as the most suitable distributions for representing the statistical properties of extreme rainfall in Selangor. Monte Carlo simulation was used for performance evaluation, and it showed that the method of TL-moments was more efficient for lower quantile estimation compared with the L-moments.

  11. Relative response of TL and component-resolved OSL to alpha and beta radiations in annealed sedimentary quartz

    International Nuclear Information System (INIS)

    Polymeris, George S.; Afouxenidis, Dimitrios; Raptis, Spyridoula; Liritzis, Ioannis; Tsirliganis, Nestor C.; Kitis, George

    2011-01-01

    Knowledge of the relative luminescence response to alpha and beta radiation is very important in TL and OSL dating. In the present study the relative alpha to beta response is studied in a sedimentary quartz sample, previously fired at 900 deg. C for 1 h, in the dose region between 1 and 128 Gy, for both thermoluminescence (TL) and linearly modulated optically stimulated luminescence (LM - OSL). The LM - OSL measurements were performed at room temperature and at 125 deg. C. All OSL signals were deconvolved into their individual components. Comparison of OSL curves after alpha and beta irradiation strongly supports that quartz OSL components follow first order kinetics in both cases. In the case of TL, the relative alpha to beta response is found to be very different for each TL glow-peak, but it does not depend strongly on irradiation dose. In the case of LM - OSL measurements, it is found that the relative behaviour of the alpha to beta response is different for three distinct regions, namely the fast OSL component, the region of medium OSL component originating from the TL glow-peak at 110 deg. C when stimulation takes place at room temperature and finally the region of slow OSL component. Following stimulation at ambient temperature, the relative alpha to beta response of all components was not observed to depend significantly on dose, with the value of ratio being 0.03 and a tendency to decrease with increasing dose. However, in the case of measurements performed at 125 deg. C, the relative response of the fast components is much enhanced, and for the remaining components it increases with increasing dose. Special care must be taken to examine the relative alpha to beta response of the fast component at 125 deg. C which contrasts the relative response of the TL peak at ca. 325 deg. C. The implications for the dating of annealed quartz are also briefly discussed. - Highlights: → Relative alpha to beta response for TL and LM-OSL is studied in annealed

  12. The neutron diffraction of molten TlCl, TlBr, and TlI

    International Nuclear Information System (INIS)

    Satow, T.; Uemura, O.; Hoshino, K.; Watanabe, T.

    1984-01-01

    Structure factors S(K) for liquid TlCl, TlBr, and TlI are determined by neutron diffraction measurements. Atomic radial distribution functions (RDF) derived from S(K) are presented. All RDF values are slightly smaller than those of their solid state counter parts. Results show that TlX has a tendency not to retain cesium-chloride type local order, but to take sodium-chloride type order when melting

  13. Relative thermoluminescent efficiencies proton/gamma and helium/gamma of peaks of high temperature in TLD-100 dosemeters

    International Nuclear Information System (INIS)

    Flores M, E.

    2007-01-01

    The increase of the applications of ion beams in radiotherapy treatments has generated interest in the study of the thermoluminescent materials (TL) that allow to determine the applied doses. A way to quantify the TL response from these materials to ions is by means of the relative thermoluminescent efficiency. In the group of Thermoluminescent dosimetry of the Institute of Physics of the UNAM (IFUNAM) the thermoluminescent response of the TLD-100 dosemeters has been studied, which present a glow curve characteristic with several peaks that correspond to traps and luminescent centers in the material. The stable peaks know each other as 4, 5, 6a, 6b, 7, 8, 9 and 10. The efficiencies should be measured using the response so much to the radiation of interest (in this case protons and helium ions) as the response to gamma radiation. In previous works with ions of low energy taken place in the Pelletron accelerator of the IFUNAM was only measured the TL efficiency for the peak 5 and the total signal. It had not been possible to measure the efficiency of the peaks of high temperature (6a-10) because, for the gamma radiation, the peaks of high temperature show very small signals; however, recently Massillon carries out measures of efficiency TL of peaks of high temperature for ions of intermediate energy using a protocol special of reading and of deconvolution that allows to measure the signals coming from the peaks of high temperature. In this work is implemented this same protocol to complete the study of TL efficiencies at low energy of protons and helium and to determine if the values of efficiency depend on the used reading protocol. For it is reported it measures of the relative efficiency of the peaks of high temperature from the TLD-100 exposed to protons of 1.5 MeV and nuclei of helium of 3 and 7.5 MeV. (Author)

  14. Global parameterization and validation of a two-leaf light use efficiency model for predicting gross primary production across FLUXNET sites: TL-LUE Parameterization and Validation

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Yanlian [Jiangsu Provincial Key Laboratory of Geographic Information Science and Technology, School of Geographic and Oceanographic Sciences, Nanjing University, Nanjing China; Joint Center for Global Change Studies, Beijing China; Wu, Xiaocui [International Institute for Earth System Sciences, Nanjing University, Nanjing China; Joint Center for Global Change Studies, Beijing China; Ju, Weimin [International Institute for Earth System Sciences, Nanjing University, Nanjing China; Jiangsu Center for Collaborative Innovation in Geographic Information Resource Development and Application, Nanjing China; Chen, Jing M. [International Institute for Earth System Sciences, Nanjing University, Nanjing China; Joint Center for Global Change Studies, Beijing China; Wang, Shaoqiang [Key Laboratory of Ecosystem Network Observation and Modeling, Institute of Geographic Sciences and Natural Resources Research, Chinese Academy of Science, Beijing China; Wang, Huimin [Key Laboratory of Ecosystem Network Observation and Modeling, Institute of Geographic Sciences and Natural Resources Research, Chinese Academy of Science, Beijing China; Yuan, Wenping [State Key Laboratory of Earth Surface Processes and Resource Ecology, Future Earth Research Institute, Beijing Normal University, Beijing China; Andrew Black, T. [Faculty of Land and Food Systems, University of British Columbia, Vancouver British Columbia Canada; Jassal, Rachhpal [Faculty of Land and Food Systems, University of British Columbia, Vancouver British Columbia Canada; Ibrom, Andreas [Department of Environmental Engineering, Technical University of Denmark (DTU), Kgs. Lyngby Denmark; Han, Shijie [Institute of Applied Ecology, Chinese Academy of Sciences, Shenyang China; Yan, Junhua [South China Botanical Garden, Chinese Academy of Sciences, Guangzhou China; Margolis, Hank [Centre for Forest Studies, Faculty of Forestry, Geography and Geomatics, Laval University, Quebec City Quebec Canada; Roupsard, Olivier [CIRAD-Persyst, UMR Ecologie Fonctionnelle and Biogéochimie des Sols et Agroécosystèmes, SupAgro-CIRAD-INRA-IRD, Montpellier France; CATIE (Tropical Agricultural Centre for Research and Higher Education), Turrialba Costa Rica; Li, Yingnian [Northwest Institute of Plateau Biology, Chinese Academy of Sciences, Xining China; Zhao, Fenghua [Key Laboratory of Ecosystem Network Observation and Modeling, Institute of Geographic Sciences and Natural Resources Research, Chinese Academy of Science, Beijing China; Kiely, Gerard [Environmental Research Institute, Civil and Environmental Engineering Department, University College Cork, Cork Ireland; Starr, Gregory [Department of Biological Sciences, University of Alabama, Tuscaloosa Alabama USA; Pavelka, Marian [Laboratory of Plants Ecological Physiology, Institute of Systems Biology and Ecology AS CR, Prague Czech Republic; Montagnani, Leonardo [Forest Services, Autonomous Province of Bolzano, Bolzano Italy; Faculty of Sciences and Technology, Free University of Bolzano, Bolzano Italy; Wohlfahrt, Georg [Institute for Ecology, University of Innsbruck, Innsbruck Austria; European Academy of Bolzano, Bolzano Italy; D' Odorico, Petra [Grassland Sciences Group, Institute of Agricultural Sciences, ETH Zurich Switzerland; Cook, David [Atmospheric and Climate Research Program, Environmental Science Division, Argonne National Laboratory, Argonne Illinois USA; Arain, M. Altaf [McMaster Centre for Climate Change and School of Geography and Earth Sciences, McMaster University, Hamilton Ontario Canada; Bonal, Damien [INRA Nancy, UMR EEF, Champenoux France; Beringer, Jason [School of Earth and Environment, The University of Western Australia, Crawley Australia; Blanken, Peter D. [Department of Geography, University of Colorado Boulder, Boulder Colorado USA; Loubet, Benjamin [UMR ECOSYS, INRA, AgroParisTech, Université Paris-Saclay, Thiverval-Grignon France; Leclerc, Monique Y. [Department of Crop and Soil Sciences, College of Agricultural and Environmental Sciences, University of Georgia, Athens Georgia USA; Matteucci, Giorgio [Viea San Camillo Ed LellisViterbo, University of Tuscia, Viterbo Italy; Nagy, Zoltan [MTA-SZIE Plant Ecology Research Group, Szent Istvan University, Godollo Hungary; Olejnik, Janusz [Meteorology Department, Poznan University of Life Sciences, Poznan Poland; Department of Matter and Energy Fluxes, Global Change Research Center, Brno Czech Republic; Paw U, Kyaw Tha [Department of Land, Air and Water Resources, University of California, Davis California USA; Joint Program on the Science and Policy of Global Change, Massachusetts Institute of Technology, Cambridge USA; Varlagin, Andrej [A.N. Severtsov Institute of Ecology and Evolution, Russian Academy of Sciences, Moscow Russia

    2016-04-06

    Light use efficiency (LUE) models are widely used to simulate gross primary production (GPP). However, the treatment of the plant canopy as a big leaf by these models can introduce large uncertainties in simulated GPP. Recently, a two-leaf light use efficiency (TL-LUE) model was developed to simulate GPP separately for sunlit and shaded leaves and has been shown to outperform the big-leaf MOD17 model at 6 FLUX sites in China. In this study we investigated the performance of the TL-LUE model for a wider range of biomes. For this we optimized the parameters and tested the TL-LUE model using data from 98 FLUXNET sites which are distributed across the globe. The results showed that the TL-LUE model performed in general better than the MOD17 model in simulating 8-day GPP. Optimized maximum light use efficiency of shaded leaves (εmsh) was 2.63 to 4.59 times that of sunlit leaves (εmsu). Generally, the relationships of εmsh and εmsu with εmax were well described by linear equations, indicating the existence of general patterns across biomes. GPP simulated by the TL-LUE model was much less sensitive to biases in the photosynthetically active radiation (PAR) input than the MOD17 model. The results of this study suggest that the proposed TL-LUE model has the potential for simulating regional and global GPP of terrestrial ecosystems and it is more robust with regard to usual biases in input data than existing approaches which neglect the bi-modal within-canopy distribution of PAR.

  15. Comparison of total experimental and theoretical absolute γ-ray detection efficiencies of a cylindrical NaI(Tl) crystal

    International Nuclear Information System (INIS)

    Uosif, M.A.; El-Taher, A.

    2005-01-01

    A new fit function has been developed to calculate theoretically the absolute gamma ray detection efficiencies (ηTh) of a cylindrical NaI(Tl) crystal, for calculating the absolute efficiency at any interesting gamma energy in the energy range between 10 and 1300 keV and distance between 0 and 8 cm. The total absolute gamma ray detection efficiencies have been calculated for five detectors, four are 2x2 and one is 3x 3 inches NaI(Tl) crystal at different distances. The absolute efficiency of the different detectors was calculated at the specific energy of the standard sources for each measuring distances. In this calculation, experimental (ηExp) and theoretical (ηTh) have been calculated. The uncertainties of efficiency calibration have been calculated also for quality control. Measurements were performed with calibrated point source. Gamma-ray energies under consideration were 0.356, 0.662, 1.17 and 1.33 MeV. The differences between (ηExp) and (ηTh) at these energies are 1.30E-06, 7.99E-05, 2.29E-04 and 2.42E-04 respectively. The results obtained on the basis of (ηExp) and (ηTh) seem to be in very good agreement

  16. Evaluation of the relative thermoluminescence efficiency of LiF:Mg,Ti and LiF:Mg,Cu,P TL detectors to low-energy heavy ions

    DEFF Research Database (Denmark)

    Gieszczyk, W.; Bilski, P.; Olko, P.

    2013-01-01

    and xenon ion beams, at energies ranging from 5.0 to 9.3 MeV/n. Supra- and sublinear response was found, for the MTS-N and MCP-N, respectively, similarly as observed for γ-rays. However, the level of nonlinearity of response of studied detectors is strongly reduced by increasing values of the ion ionization...... density (no supralinearity for Xe ions, for MTS-N, within calculated uncertainties). The growth of high-temperature TL peaks, with increasing ionization density, was observed for MCP-N, what was not previously reported. At the whole range of applied energies higher efficiencies were noted for MTS......-N, for all ion species. A decrease of the efficiency with decrease of the ion energy was confirmed, for both types of studied detectors. At a given energy, higher efficiency was observed for lighter ions, because of the lower ionization density. Significantly higher decrease of the efficiency was measured...

  17. Doped Tl-1212 and Tl-1223 superconductors

    International Nuclear Information System (INIS)

    Eder, M.H.

    2001-09-01

    This work describes the preparation and characterization of thallium-lead-strontium-barium-calcium-(uranium)-copperoxide (Tl-1212, Tl-1223) high-temperature superconductors. The precursors were prepared via nitrate method. After calcination the oxidic powders were mixed with stoichiometric amounts of an Tl 2 O 3 , PbO, Er 2 O 3 and Gd 2 O 3 by milling and afterwards uniaxial compressed. Sintering was carried out in silver foils. X-ray diffractometry and high-resolution microscopy in combination with scanning electron microscopy (including EDAX) were used to study the influence of varying thallium/lead-, strontium/barium-, calcium/rare earth element ratios and the effect of uranium on the phase composition and microstructure of bulk superconductors. Furthermore the influence of the composition on the electrical and magnetical properties was studied. On phase pure Tl-1212 and Tl-1223 superconductors NMR-measurements were done. Small amounts of gadolinium and erbium instead of calcium and excess-uranium have a positive impact on the electrical and magnetical properties of the Tl-1223 superconductors. Higher amounts of these doping elements favor the Tl-1212 phase. Tl-1212 superconductors with varying thallium/lead- strontium/barium- and calcium/gadolinium ratios were prepared phasepure in wide range of doping. Transition temperatures up to 96 K were achieved. It was shown that lead has an oxidation number of +4 and thallium of +3. (author)

  18. Theories of TL systems: Failures, successes, conflicts, trends: Insights into possible future materials and techniques

    International Nuclear Information System (INIS)

    Horowitz, Y. S.; Belaish, Y.; Oster, L.

    2006-01-01

    In this paper some of the many theoretical models dealing with characteristics of TL materials are discussed. Special attention is given to some of the models dealing with the effects of ionisation density, that is Modified Track Structure Theory (MTST) and Micro-dosimetric Track Structure Theory (MTT) for the calculation of Heavy Charged Particle relative TL efficiencies, as well as solid-state models based on conduction band/valence band theory. Failures, successes, conflicts and trends are highlighted as well as a peek into future avenues of research for dosimetric TL materials. (authors)

  19. Spectrophotometric determination of Tl carrier in 201Tl-TlCl injection

    International Nuclear Information System (INIS)

    Gong Quansheng; Jing Lie

    1997-01-01

    A simple and sensitive method for the spectrophotometric determination of carrier content (Thallium) in 201 Tl-TlCl injection is described. Thallium (I) is oxidised to Thallium (III) by aqueous bromine, then excess bromine is removed by adding sulfosalicylic acid. In buffer solution (NH 4 Cl-NH 4 OH) at pH 11.7 with the presence of emulsifier OP, thallium (III) and cadion form a complex having an absorption maximum at 469 nm with a molar absorptivity of 1.37 x 10 4 m 2 /mol. Beer's law is obeyed in the concentration range of 0-7 μg/5 mL. The effect of impurity elements in 201 Tl-TlCl injection is examined. It is an ideal method for the analysis of radioactive solution

  20. Intrinsic thermoluminescence of NaCl:Tl in UV dosimetry

    International Nuclear Information System (INIS)

    Barghare, S.P.; Joshi, R.V.; Joshi, T.R.; Kathuria, S.P.

    1982-01-01

    NaCl:Tl(T) phosphor is found to have high intrinsic thermoluminescence (TL) sensitivity to 253.7 nm UV-radiation. The dosimetric glow peak II grows sublinearly with increase in UV dose in the range 10 3 to 10 6 JM -2 . The other requirements of an efficient dosimeter material such as high storage stability, matching of the spectral response of detector tube and TL-emission from phosphor, reproducibility, desirable size and shape, easy availability in powder, pellet and crystal forms at cheaper rates, and repeated re-usability of the same phosphor without much difficulty, etc., are additional factors which strengthen the claim of NaCl:Tl(T) phosphor as UV dosimetric material. It is proposed that present NaCl:Tl(T) material is suitable TL-phosphor for UV dosimetry in the range 10 3 to 10 6 JM -2 . (author)

  1. Full energy peak efficiency of NaI(Tl) gamma detectors and its analytical and semi-empirical representations

    International Nuclear Information System (INIS)

    Sudarshan, M.; Joseph, J.; Singh, R.

    1992-01-01

    The validity of various analytical functions and semi-empirical formulae proposed for representing the full energy peak efficiency (FEPE) curves of Ge(Li) and HPGe detectors has been tested for the FEPE of 7.6 cm x 7.6 cm and 5 cm x 5 cm Nal(Tl) detectors in the gamma energy range from 59.5 to 1408.03 keV. The functions proposed by East, and McNelles and Campbell provide by far the best representations of the present data. The semi-empirical formula of Mowatt describes the present data very well. The present investigation shows that some of the analytical functions and semi-empirical formulae, which represent the FEPE of the Ge(Li) and HPGe detectors very well, can be quite fruitfully used for Nal(Tl) detectors. (Author)

  2. Converting Hg-1212 to Tl-2212 via Tl-Hg cation exchange in combination with Tl cation intercalation

    International Nuclear Information System (INIS)

    Zhao Hua; Wu, Judy Z

    2007-01-01

    In a cation exchange process developed recently for epitaxy of HgBa 2 CaCu 2 O 6 (Hg-1212) thin films, TlBa 2 CaCu 2 O 7 (Tl-1212) or Tl 2 Ba 2 CaCu 2 O 9 (Tl-2212) precursor films were employed as the precursor matrices and Hg-1212 was obtained by replacing Tl cations on the precursor lattice with Hg cations. The reversibility of the cation exchange dictates directly the underlying mechanism. Following our recent success in demonstrating a complete reversibility within '1212' structure, we show the conversion from Hg-1212 to Tl-2212 can be achieved via two steps: conversion from Hg-1212 to Tl-1212 followed by Tl intercalation to form double Tl-O plans in each unit cell. The demonstrated reversibility of the cation exchange process has confirmed the process is a thermal perturbation of weakly bonded cations on the lattice and the direction of the process is determined by the population ratio between the replacing cations and that to be replaced

  3. TL dosimetric properties BAM:EU

    International Nuclear Information System (INIS)

    Rao, Bellam N.; Murthy, K.V.R.; Subba Rao, B.; Saiprasad, A.S.

    2011-01-01

    In phosphor area today top priority is the replacement of the high performance but very expensive rare earth activated phosphors with cheaper materials. This essentially means replacing the rare earth ions with transition metal ions or post transition ions. Now a day's phosphors are used in various fields. After World War II, the advances in the optical spectroscopy of solids, especially those of transition metals ions help to evolve research on phosphor and solid state luminescence. In 1960 efficient rare earth activated phosphors were developed for use in color TV (Tb 3+ green, Eu 3+ red, and Dy 3+ yellow). In 1970 tricolor lamp was introduced blue emission from Ce 3+ + Tb 3+ pair was used in tricolor lamps. At present combination of halo phosphor and tri-band phosphor blend is used in many lamp as a compromise between performance, phosphor cost and the lamp making Cost. Thermo luminescence of 0.5 Gy X-ray irradiated BAM.Eu has been studied. The irradiated phosphor has been studied for its TL dosimetric properties one week after irradiation and after 100 weeks of storage. Interesting TL results are reported in the present paper. Heating rate used in the present experiment is 6.6 deg C/Sec. The following two figures are on TL recorded 100 weeks after irradiation and TL recorded after 235 weeks of storage. Before storage for 100 weeks the TL glow curve with a hump around 180 deg C followed by a peak at 273 deg C. After storage for 100 weeks the TL pattern changes entirely. i.e. the composite TL peak structure emerged as two well resolved peaks and with slightly higher TL peak temperatures at 215 deg C and 300 deg C. Normally after storage for 100 weeks the peak at 190 deg C reduces in its intensity or disappears in some cases, instead of that the peak appears at 215 deg C as well resolved peak and its intensity is almost comparable to that of 300 deg C peak. Since the TL phenomenon observed is interesting the two well resolved, isolated, high intensity peaks

  4. Superconducting transition in TlBiTe/sub 2/ and TlTe compounds

    Energy Technology Data Exchange (ETDEWEB)

    Kantser, V G; Popovich, N S; Sidorenko, A S

    1985-10-01

    On the basis of zone structure calculation for TlBiTe/sub 2/ and TlTe it is found that TlBiTe/sub 2/ is a narrow-gap semiconductor and TlTe is a p-metal. At Tsub(c)=0.19 K TlTe is found to experience the superconducting transition. In TlBiTe/sub 2/ superconductivity is not observed to occur up to 0.05 K, since there is a possibility of occupying the high density of states zones because they are remote from actual ones. The earlier discovered superconducting transition in TlBiTe/sub 2/ is inherent in the alien phase of TlTe.

  5. The use of thallium diethyldithiocarbamate for mapping CNS potassium metabolism and neuronal activity: Tl+ -redistribution, Tl+ -kinetics and Tl+ -equilibrium distribution.

    Science.gov (United States)

    Wanger, Tim; Scheich, Henning; Ohl, Frank W; Goldschmidt, Jürgen

    2012-07-01

    The potassium (K(+)) analogue thallium (Tl(+)) can be used as a tracer for mapping neuronal activity. However, because of the poor blood-brain barrier (BBB) K(+) -permeability, only minute amounts of Tl(+) enter the brain after systemic injection of Tl(+) -salts like thallium acetate (TlAc). We have recently shown that it is possible to overcome this limitation by injecting animals with the lipophilic chelate complex thallium diethyldithiocarbamate (TlDDC), that crosses the BBB and releases Tl(+) prior to neuronal or glial uptake. TlDDC can thus be used for mapping CNS K(+) metabolism and neuronal activity. Here, we analyze Tl(+) -kinetics in the rodent brain both experimentally and using simple mathematical models. We systemically injected animals either with TlAc or with TlDDC. Using an autometallographic method we mapped the brain Tl(+) -distribution at various time points after injection. We show that the patterns and kinetics of Tl(+) -redistribution in the brain are essentially the same irrespective of whether animals have been injected with TlAc or TlDDC. Data from modeling and experiments indicate that transmembrane Tl(+) -fluxes in cells within the CNS in vivo equilibrate at similar rates as K(+) -fluxes in vitro. This equilibration is much faster than and largely independent of the equilibration of Tl(+) -fluxes across the BBB. The study provides further proof-of-concept for the use of TlDDC for mapping neuronal activity and CNS K(+) -metabolism. A theoretical guideline is given for the use of K(+) -analogues for imaging neuronal activity with general implications for the use of metal ions in neuroimaging. © 2012 The Authors. Journal of Neurochemistry © 2012 International Society for Neurochemistry.

  6. Calculated Absolute Detection Efficiencies of Cylindrical Nal (Tl) Scintillation Crystals for Aqueous Spherical Sources

    Energy Technology Data Exchange (ETDEWEB)

    Strindehag, O; Tollander, B

    1968-08-15

    Calculated values of the absolute total detection efficiencies of cylindrical scintillation crystals viewing spherical sources of various sizes are presented. The calculation is carried out for 2 x 2 inch and 3 x 3 inch Nal(Tl) crystals and for sources which have the radii 1/4, 1/2, 3/4 and 1 times the crystal radius. Source-detector distances of 5-20 cm and gamma energies in the range 0.1 - 5 MeV are considered. The correction factor for absorption in the sample container wall and in the detector housing is derived and calculated for a practical case.

  7. Phase diagrams of novel Tl{sub 4}SnSe{sub 4}–TlSbSe{sub 2}–Tl{sub 2}SnSe{sub 3} quasi-ternary system following DTA and X-ray diffraction

    Energy Technology Data Exchange (ETDEWEB)

    Barchiy, I.E.; Tatzkar, A.R. [Department of Chemistry, Uzhgorod National University, Pidgirna St., 46, Uzhgorod 88000 (Ukraine); Fedorchuk, A.O. [Department of Inorganic and Organic Chemistry, Lviv National University of Veterinary Medicine and Biotechnologies, Pekarska St., 50, Lviv 79010 (Ukraine); Plucinski, K., E-mail: kpluc2006@wp.pl [Electronics Department, Military University Technology, Warsaw, Kaliskiego 2, Warsaw 00-908 (Poland)

    2016-06-25

    Phase relation in the Tl{sub 4}SnSe{sub 4}–TlSbSe{sub 2}–Tl{sub 2}SnSe{sub 3} quasiternary system were studied by the DTA and X-ray diffraction in combination with mathematical modeling. The phase diagrams of the Tl{sub 4}SnSe{sub 4}–TlSbSe{sub 2} and Tl{sub 2}SnSe{sub 3}–TlSbSe{sub 2} systems, the perspective views of the phase interaction in the ternary system, the liquidus surface projection, the isothermal section at 423 K were built for the first time. The Tl{sub 4}SnSe{sub 4}–TlSbSe{sub 2}–Tl{sub 2}SnSe{sub 3} system is of the invariant eutectic type and is characterized by the formation of limited solid solutions following initial ternary compounds. New complex compounds are not formed. - Highlights: • Two Tl{sub 4}SnSe{sub 4}–TlSbSe{sub 2},Tl{sub 2}SnSe{sub 3}–TlSbSe{sub 2} systems were explored. • Invariant processes in the ternary system were determined. • New complex compounds were not observed in ternary system.

  8. Photopeak efficiency response function of an underwater gamma-ray NaI(Tl) detector using MCNP-X

    International Nuclear Information System (INIS)

    Salgado, William L.; Silva, Ademir X.; Salgado, Cesar M.

    2015-01-01

    This work presents a study to calculate the response function of a 1.5″ x 1″ NaI(Tl) scintillation detector when it is used in the marine environment in the energy range from 20 keV to 662 keV. The method takes into account both the scattering of photons in the water and the detection mechanism of the detector. In addition, the calculation of the response function of the whole system is essential for suppressing the background of the measurement and for estimating the concentration of the involved radionuclides, especially given the greater probability of primary gamma photons undergoing multiple scattering events before they interact with the detector. The experimental photopeak efficiency measurements for point sources were compared with the simulated results under the same conditions of the experimental setup to validate the simulation of the detector. Monte Carlo simulations were performed using the MCNP-X code for the investigation of gamma-ray absorption in water in different brines. The energy resolution curve was used to improve the response of the mathematical simulation of the detector. The detector’s simulation was based on information obtained from the gammagraphy technique. Both dimensions and materials were used for the calculation with the MCNP-X code. The photopeak efficiency of a NaI(Tl) detector for different radionuclides in the aquatic environment with different salinities was calculated. (author)

  9. Prediction of half-metallic properties in TlCrS{sub 2} and TlCrSe{sub 2} based on density functional theory

    Energy Technology Data Exchange (ETDEWEB)

    Hashimzade, F.M.; Huseinova, D.A. [Institute of Physics, National Academy of Sciences of Azerbaijan, AZ 1143 Baku (Azerbaijan); Jahangirli, Z.A. [Institute of Physics, National Academy of Sciences of Azerbaijan, AZ 1143 Baku (Azerbaijan); Institute of Radiation Problems, National Academy of Sciences of Azerbaijan, AZ 1143 Baku (Azerbaijan); Mehdiyev, B.H., E-mail: bachschi@yahoo.de [Institute of Physics, National Academy of Sciences of Azerbaijan, AZ 1143 Baku (Azerbaijan)

    2017-08-01

    Highlights: • Half-metallic properties of TlCrS2, TlCrSe2 and hypothetical TlCrSSe have been investigated by first-principles all-electron full-potential linearized augmented plane wave plus local orbital (FP-LAPW+lo) method based on density functional theory (DFT). • Total magnetic moment keeps its integer value on a relatively wide range of changes in volume (−10% ÷ 10%) for TlCrS2 and TlCrSSe, while total magnetic moment TlCrSe2 decreases with increasing volume, approaching to integer value 3 μB. • The states at the Fermi level in the case of spin-up channel consist of a hybridization of p-states of the atom S(Se) with d-states of Cr. - Abstract: Half-metallic properties of TlCrS{sub 2}, TlCrSe{sub 2} and hypothetical TlCrSSe have been investigated by first-principles all-electron full-potential linearized augmented plane wave plus local orbital (FP-LAPW+lo) method based on density functional theory (DFT). The results of calculations show that TlCrS{sub 2} and TlCrSSe are half-metals with energy gap (E{sub g}) ∼0.12 eV for spin-down channel. Strong hybridization of p-state of chalchogen and d-state of Cr leads to bonding and antibonding states and subsequently to the appearance of a gap in spin-down channel of TlCrS{sub 2} and TlCrSSe. In the case of TlCrSe{sub 2}, there is a partial hybridization and p-state is partially present in the DOS at Fermi level making this compound nearly half-metallic. The present calculations revealed that total magnetic moment keeps its integer value on a relatively wide range of changes in volume (−10% ÷ 10%) for TlCrS{sub 2} and TlCrSSe, while total magnetic moment of TlCrSe{sub 2} decreases with increasing volume approaching to integer value 3 μB.

  10. 205Tl experiment

    International Nuclear Information System (INIS)

    Henning, W.; Kutschera, W.; Ernst, H.

    1984-01-01

    205 Tl has been previously proposed as a geological detector for solar neutrinos, making use of the reaction 205 Tl(nu, e - ) 205 Pb with a neutrino threshold of only approx. = 43 keV. We report on an experiment performed to study the feasibility of detecting radioactive 205 Pb nuclei (T/sub 1/2/ = 15 million years) at very low concentrations using the recently developed technique of accelerator mass spectrometry. Employing the high-energy ion beams of good quality from the UNILAC heavy-ion accelerator at the GSI Darmstadt, we are able to demonstrate a suppression of neighbouring isotopes to better than 1 in 10 16 and of neighbouring elements to about 1 in 10 3 . While these results are very encouraging, the minimum number of atoms detectable is still severely limited by the efficiency of producing multiply-charged ions from present ion sources. Future improvements in ion-source performance are briefly discussed

  11. Impact of precursor purity on optical properties and radiation detection of CsI:Tl scintillators

    Energy Technology Data Exchange (ETDEWEB)

    Saengkaew, Phannee; Cheewajaroen, Kulthawat; Yenchai, Chadet; Thong-aram, Decho [Chulalongkorn University, Department of Nuclear Engineering, Faculty of Engineering, Bangkok (Thailand); Sanorpim, Sakuntam [Chulalongkorn University, Department of Physics, Faculty of Science, Bangkok (Thailand); Jitpukdee, Manit [Kasetsart University, Department of Applied Radiation and Isotope, Faculty of Science, Bangkok (Thailand); Yordsri, Visittapong; Thanachayanont, Chanchana [Ministry of Science and Technology, National Metal and Materials Technology Center, National Science and Technology Development Agency, Pathumthani (Thailand); Nuntawong, Noppadon [Ministry of Science and Technology, National Electronic and Computer Technology Center, National Science and Technology Development Agency, Pathumthani (Thailand)

    2016-08-15

    Cesium iodide doped with thallium (CsI:Tl) crystals was grown to develop the gamma-ray detectors by using low-cost raw materials. Effect of impurities on optical properties and radiation detection performance was investigated. By a modified homemade Bridgman-Stockbarger technique, CsI:Tl samples were grown in two levels of CsI and TlI reactant materials, i.e., having as a very high purity of 99.999 % and a high purity of 99.9 %. XRD measurements indicate CsI:Tl crystals having a good quality with a dominant (110) plane. Having a cubic structure, a lattice constant of CsI crystals of 0.4574 nm and a crystallite size of 43.539 nm were obtained. From the lower-purity raw materials, calcite was found in an orange crystal with a lattice constant of 0.4560 nm and a crystallite size of 43.089 nm. By PL measurements, the optical properties of the CsI:Tl crystals were analyzed. ∝540-nm-wavelength PL peak was observed from the colorless high-purity crystal, and ∝600-nm-wavelength PL peak was observed from the orange crystal. The brighter PL emission was obtained from the orange crystals suggesting impurities. CsI:Tl surface morphology by SEM exhibited a smooth surface with some parallel crystal facets. For electrical properties of high-quality CsI:Tl crystals, the electrical resistances were 230 ± 16 MΩ in cross-sectional direction and 714 ± 136 MΩ in vertical direction with respect to more homogeneous crystal quality in cross-sectional direction than that in vertical direction. TEM measurement was applied to evaluate the microstructure of colorless CsI:Tl crystal with different patterns of a cubic structure. Both CsI:Tl crystals show good efficiencies and good resolutions. Maintaining the same electronic conditions and amplifications, the colorless CsI:Tl scintillators represented a higher detection efficiency at 122 keV of Co-57 of 78.4 % and the energy resolution of 23.3 % compared to the detection efficiency of 75.9 % and the energy resolution of 34.6 % of the

  12. Efficiency calibration and coincidence summing correction for large arrays of NaI(Tl) detectors in soccer-ball and castle geometries

    International Nuclear Information System (INIS)

    Anil Kumar, G.; Mazumdar, I.; Gothe, D.A.

    2009-01-01

    Efficiency calibration and coincidence summing correction have been performed for two large arrays of NaI(Tl) detectors in two different configurations. They are, a compact array of 32 conical detectors of pentagonal and hexagonal shapes in soccer-ball geometry and an array of 14 straight hexagonal NaI(Tl) detectors in castle geometry. Both of these arrays provide a large solid angle of detection, leading to considerable coincidence summing of gamma rays. The present work aims to understand the effect of coincidence summing of gamma rays while determining the energy dependence of efficiencies of these two arrays. We have carried out extensive GEANT4 simulations with radio-nuclides that decay with a two-step cascade, considering both arrays in their realistic geometries. The absolute efficiencies have been simulated for gamma energies from 700 to 2800 keV using four different double-photon emitters, namely, 60 Co, 46 Sc, 94 Nb and 24 Na. The efficiencies so obtained have been corrected for coincidence summing using the method proposed by Vidmar et al. . The simulations have also been carried out for the same energies assuming mono-energetic point sources, for comparison. Experimental measurements have also been carried out using calibrated point sources of 137 Cs and 60 Co. The simulated and the experimental results are found to be in good agreement. This demonstrates the reliability of the correction method for efficiency calibration of two large arrays in very different configurations.

  13. Efficiency calibration and coincidence summing correction for large arrays of NaI(Tl) detectors in soccer-ball and castle geometries

    Energy Technology Data Exchange (ETDEWEB)

    Anil Kumar, G., E-mail: anilg@tifr.res.i [Department of Nuclear and Atomic Physics, Tata Institute of Fundamental Research, Homi Bhabha Road, Colaba, Mumbai 400005 (India); Mazumdar, I.; Gothe, D.A. [Department of Nuclear and Atomic Physics, Tata Institute of Fundamental Research, Homi Bhabha Road, Colaba, Mumbai 400005 (India)

    2009-11-21

    Efficiency calibration and coincidence summing correction have been performed for two large arrays of NaI(Tl) detectors in two different configurations. They are, a compact array of 32 conical detectors of pentagonal and hexagonal shapes in soccer-ball geometry and an array of 14 straight hexagonal NaI(Tl) detectors in castle geometry. Both of these arrays provide a large solid angle of detection, leading to considerable coincidence summing of gamma rays. The present work aims to understand the effect of coincidence summing of gamma rays while determining the energy dependence of efficiencies of these two arrays. We have carried out extensive GEANT4 simulations with radio-nuclides that decay with a two-step cascade, considering both arrays in their realistic geometries. The absolute efficiencies have been simulated for gamma energies from 700 to 2800 keV using four different double-photon emitters, namely, {sup 60}Co, {sup 46}Sc, {sup 94}Nb and {sup 24}Na. The efficiencies so obtained have been corrected for coincidence summing using the method proposed by Vidmar et al. . The simulations have also been carried out for the same energies assuming mono-energetic point sources, for comparison. Experimental measurements have also been carried out using calibrated point sources of {sup 137}Cs and {sup 60}Co. The simulated and the experimental results are found to be in good agreement. This demonstrates the reliability of the correction method for efficiency calibration of two large arrays in very different configurations.

  14. Relative thermoluminescent efficiencies proton/gamma and helium/gamma of high temperature peaks in TLD-100 dosemeters

    International Nuclear Information System (INIS)

    Flores M, E.; Avila, O.; Rodriguez V, M.; Massillon, J.L.G.; Buenfil A, E.; Ruiz T, C.; Brandan, M.E.; Gamboa De Buen, I.

    2007-01-01

    This work presents measures of relative thermoluminescent efficiency of those high temperature peaks of TLD-100 dosemeters exposed to protons of 1.5 MeV and to helium nuclei of 3 and 7.5 MeV. A rigorous reading and of deconvolution protocol was used for the calculation of the TL efficiencies. Additionally an Excel program that facilitated the deconvolution adjustment process of the glow curves was elaborated. (Author)

  15. Use of universal functional optimisation for TL glow curve analysis

    International Nuclear Information System (INIS)

    Pernicka, F.; Linh, H.Q.

    1996-01-01

    The effective use of any TL instrument requires an efficient software package to be able to fulfil different tasks required by research and practical applications. One of the standard features of the package used at the NPI Prague is the application of the interactive modular system Universal Functional Optimisation (UFO) for glow curve deconvolution. The whole system has been tested on standard glow curves using different models of the TL process (a single peak described by the Podgorsak approximation, first order kinetics and/or general order kinetics). Calculated values of basic TL parameters (E and s) show a good agreement with the results obtained by other authors. The main advantage of the system is in its modularity that enables flexible changes in the TL model and mathematical procedures of the glow curve analysis. (author)

  16. Relative efficiency calculation of a HPGe detector using MCNPX code

    International Nuclear Information System (INIS)

    Medeiros, Marcos P.C.; Rebello, Wilson F.; Lopes, Jose M.; Silva, Ademir X.

    2015-01-01

    High-purity germanium detectors (HPGe) are mandatory tools for spectrometry because of their excellent energy resolution. The efficiency of such detectors, quoted in the list of specifications by the manufacturer, frequently refers to the relative full-energy peak efficiency, related to the absolute full-energy peak efficiency of a 7.6 cm x 7.6 cm (diameter x height) NaI(Tl) crystal, based on the 1.33 MeV peak of a 60 Co source positioned 25 cm from the detector. In this study, we used MCNPX code to simulate a HPGe detector (Canberra GC3020), from Real-Time Neutrongraphy Laboratory of UFRJ, to survey the spectrum of a 60 Co source located 25 cm from the detector in order to calculate and confirm the efficiency declared by the manufacturer. Agreement between experimental and simulated data was achieved. The model under development will be used for calculating and comparison purposes with the detector calibration curve from software Genie2000™, also serving as a reference for future studies. (author)

  17. Investigation of TL, OSL and PTTL properties of Mg2SiO4:Tb dosimeters

    International Nuclear Information System (INIS)

    Oguz, K. F.; Goekce, M.; Karali, T.; Harmansah, C.

    2010-01-01

    In this study thermoluminescence (TL) and optically stimulated luminescence (OSL) properties of Mg 2 SiO 4 :Tb in the form of sintered pellets were investigated. Mg 2 SiO 4 :Tb is a recently developed dosimetric material which offers high sensitivity for TL and OSL in dosimetric applications. Thermoluminescence glow curve of Tb doped Mg 2 SiO 4 samples show a glow peak at about 200 degree Celsius with two small peaks at about 275 and 330 degree Celsius, respectively. OSL experiments showed that blue light (470 nm) is six times more efficient than green light (532 nm) to stimulate the OSL emission. The aim of this study was to determine the TL and OSL fading properties of Mg 2 SiO 4 : Tb using OSL and TL methods. In addition, PTTL properties of the Mg 2 SiO 4 : Tb was investigated by using blue LEDs, UV lamp and blue laser. Investigations on the fading properties also showed that the TL signal fades % 10 in a period of 1 month and OSL signal fades % 10 in a period of 3 month, which then the signal remains relatively stable for longer periods.

  18. Light regimes differentially affect baseline transcript abundance of stress-axis and (neurodevelopment-related genes in zebrafish (Danio rerio, Hamilton 1822 AB and TL larvae

    Directory of Open Access Journals (Sweden)

    Ruud van den Bos

    2017-11-01

    Full Text Available Many strains of zebrafish (Danio rerio are readily available. Earlier we observed differences between AB and Tupfel long-fin (TL larvae regarding baseline hypothalamus-pituitary-interrenal (HPI axis activity and (neurodevelopment. Light regimes, i.e. 14 h light:10 h dark and 24 h continuous dark or light, affect hatching rate and larval growth. Here, we assessed baseline transcript abundance of HPI-axis-related genes and (neurodevelopment-related genes of AB and TL larvae (5 days post fertilisation using these light regimes. A principal component analysis revealed that in AB larvae the baseline expression of HPI-axis-related genes was higher the more hours of light, while the expression of (neurodevelopment-related genes was higher under 14 h light:10 h dark than under both continuous light or dark. In TL larvae, a complex pattern emerged regarding baseline expression of HPI-axis-related and (neurodevelopment-related genes. These data extend data of earlier studies by showing that light regimes affect gene-expression in larvae, and more importantly so, strengthen the notion of differences between larvae of the AB and TL strain. The latter finding adds to the growing database of phenotypical differences between zebrafish of the AB and TL strain.

  19. Copper interactions in TlCu7S4 and TlCu7Se4

    International Nuclear Information System (INIS)

    Noren, L.; Delaplane, R.G.; Berger, R.

    1999-01-01

    Complete text of publication follows. The copper chalcogenides ACu 7 S 4 (A=NH 4 + , Tl + , Rb + ) are quasi-one-dimensional metals at ambient and higher temperatures which is due to the high mobility of copper in these structures. TlCu 7 S 4 and TlCu 7 Se 4 are isostructural compounds, space group I4/m, which can be described on the basis of a TlX 8 cube with two different Cu sites, Cu(1) and Cu(2). Cu(2)-Cu(2) zigzag chains run along the c axis with only 3/4 occupation of the Cu(2) sites. However, these two compounds differ in behaviour on cooling. The sulphide shows a polymorphic first-order transition to the CsAg 7 S 4 type (P4/n) owing to ordering of the vacancies in the Cu(2)-Cu(2) chains. In order to study the nature of the Cu(2) order/disorder in the two title compounds, a series of neutron diffraction measurements (both Bragg and diffuse scattering) were made at several temperatures from 40 to 713 K on the instrument SLAD at Studsvik. The structure at each temperature was modelled using RMC techniques. The resulting configuration show that as the temperature increases, there is a marked increase in the mobility of the Cu atoms in the Cu(2)-Cu(2) chains for TlCu 7 S 4 but not for TlCu 7 Se 4 . This is due to the initial difference in the Cu(2)-Cu(2) distances, only 2.2A for the thiocuprate, but 2.7A in the selenocuprate which explains the relative ease for Cu(2) ordering in the latter case. (author)

  20. TL transgenic mouse strains

    International Nuclear Information System (INIS)

    Obata, Y.; Matsudaira, Y.; Hasegawa, H.; Tamaki, H.; Takahashi, T.; Morita, A.; Kasai, K.

    1993-01-01

    As a result of abnormal development of the thymus of these mice, TCR αβ lineage of the T cell differentiation is disturbed and cells belonging to the TCR γδ CD4 - CD8 - double negative (DN) lineage become preponderant. The γδ DN cells migrate into peripheral lymphoid organs and constitute nearly 50% of peripheral T cells. Immune function of the transgenic mice is severely impaired, indicating that the γδ cells are incapable of participating in these reactions. Molecular and serological analyses of T-cell lymphomas reveal that they belong to the γδ lineage. Tg.Tla a -3-1 mice should be useful in defining the role of TL in normal and abnormal T cell differentiation as well as in the development of T-cell lymphomas, and further they should facilitate studies on the differentiation and function of γδ T cells. We isolated T3 b -TL gene from B6 mice and constructed a chimeric gene in which T3 b -TL is driven by the promoter of H-2K b . With the chimeric gene, two transgenic mouse strains, Tg. Con.3-1 and -2 have been derived in C3H background. Both strains express TL antigen in various tissues including skin. The skin graft of transgenic mice on C3H and (B6 X C3H)F 1 mice were rejected. In the mice which rejected the grafts, CD8 + TCRαβ cytotoxic T cells (CTL) against TL antigens were recognized. The recognition of TL by CTL did not require the antigen presentation by H-2 molecules. The results indicated that TL antigen in the skin becomes a transplantation antigen and behaves like a typical allogeneic MHC class I antigen. The facts that (B6 X C3H)F 1 mice rejected the skin expressing T3 b -TL antigen and induced CTL that killed TL + lymphomas of B6 origin revealed that TL antigen encoded by T3 b -TL is recognized as non-self in B6 mice. Experiments are now extended to analyze immune responses to TL antigen expressed on autochthonous T cell lymphomas. (J.P.N.)

  1. Solid solutions of thallium in TlGaSe2, TlGaS2, and TlInS2

    International Nuclear Information System (INIS)

    Voroshilov, Yu. V.; Potorii, M.V.; Shevchenko, S.V.

    1986-01-01

    The authors study the nature of the dissolution of thallium in ternary phases. They have synthesized alloys of the stoichiometric compositions TlGaS 2 , TlGaSe 2 , and T1InS 2 , and their solid solutions, maximally enriched in thallium, the compositions of which were Tl /SUB 1.34/ GA /SUB 0.89/ S 2 , Tl /SUB 1.31/ Ga /SUB 0.90/ Se 2 , and Tl /SUB 1.15/ In /SUB 0.95/ S /SUB 2./ . Samples were synthesized from the elemental components of the following purities: gallium of V4 grade; indium of V4 grade; thallium of T1000 grade; selenium of special purity 22-4 grade, and sulfur of special purity garde. The compositions were checked by x-ray-phase-(DRON-0.5) and microstructural-analyses with simultaneous determination of the density and microhardness of the samples. It is found that the lattic parameter increases and the increase in the density and microhardness points to strengthening of the structure during the formation of the solid solutions

  2. Calculation of total counting efficiency of a NaI(Tl) detector by hybrid Monte-Carlo method for point and disk sources

    Energy Technology Data Exchange (ETDEWEB)

    Yalcin, S. [Education Faculty, Kastamonu University, 37200 Kastamonu (Turkey)], E-mail: yalcin@gazi.edu.tr; Gurler, O.; Kaynak, G. [Department of Physics, Faculty of Arts and Sciences, Uludag University, Gorukle Campus, 16059 Bursa (Turkey); Gundogdu, O. [Department of Physics, School of Engineering and Physical Sciences, University of Surrey, Guildford GU2 7XH (United Kingdom)

    2007-10-15

    This paper presents results on the total gamma counting efficiency of a NaI(Tl) detector from point and disk sources. The directions of photons emitted from the source were determined by Monte-Carlo techniques and the photon path lengths in the detector were determined by analytic equations depending on photon directions. This is called the hybrid Monte-Carlo method where analytical expressions are incorporated into the Monte-Carlo simulations. A major advantage of this technique is the short computation time compared to other techniques on similar computational platforms. Another advantage is the flexibility for inputting detector-related parameters (such as source-detector distance, detector radius, source radius, detector linear attenuation coefficient) into the algorithm developed, thus making it an easy and flexible method to apply to other detector systems and configurations. The results of the total counting efficiency model put forward for point and disc sources were compared with the previous work reported in the literature.

  3. Calculation of total counting efficiency of a NaI(Tl) detector by hybrid Monte-Carlo method for point and disk sources

    International Nuclear Information System (INIS)

    Yalcin, S.; Gurler, O.; Kaynak, G.; Gundogdu, O.

    2007-01-01

    This paper presents results on the total gamma counting efficiency of a NaI(Tl) detector from point and disk sources. The directions of photons emitted from the source were determined by Monte-Carlo techniques and the photon path lengths in the detector were determined by analytic equations depending on photon directions. This is called the hybrid Monte-Carlo method where analytical expressions are incorporated into the Monte-Carlo simulations. A major advantage of this technique is the short computation time compared to other techniques on similar computational platforms. Another advantage is the flexibility for inputting detector-related parameters (such as source-detector distance, detector radius, source radius, detector linear attenuation coefficient) into the algorithm developed, thus making it an easy and flexible method to apply to other detector systems and configurations. The results of the total counting efficiency model put forward for point and disc sources were compared with the previous work reported in the literature

  4. TL and LOE dosimetric evaluation of diamond films exposed to beta and ultraviolet radiation; Evaluacion dosimetrica TL y LOE de peliculas de diamante expuestas a radiacion beta y ultravioleta

    Energy Technology Data Exchange (ETDEWEB)

    Preciado F, S.; Melendrez, R.; Chernov, V.; Barboza F, M. [Universidad de Sonora, A.P. 13 y A.P. 5-088, 83000 Hermosillo, Sonora (Mexico); Schreck, M. [Universitaet Augsburg, Institut fuer Physik D-86135 (Germany); Cruz Z, E. [ICN, UNAM, 04500 Mexico D.F. (Mexico)

    2005-07-01

    The diamond possesses a privileged position regarding other materials of great technological importance. Their applications go from the optics, microelectronics, metals industry, medicine and of course as dosemeter, in the registration and detection of ionizing and non ionizing radiation. In this work the results of TL/LOE obtained in two samples of diamond of 10 {mu}m thickness grown by the chemical vapor deposition method (CVD) assisted by microwave plasma. The films were deposited in a silicon substrate (001) starting from a mixture of gases composed of CH{sub 4}/H{sub 2} and 750 ppm of molecular nitrogen as dopant. The samples were exposed to beta radiation (Sr{sup 90}/ Y{sup 90}) and ultraviolet, being stimulated later on thermal (TL) and optically (LOE) to evaluate their dosimetric properties. The sample without doping presented high response TL/LOE to the ultraviolet and beta radiation. The TL glow curve of the sample without doping showed two TL peaks with second order kinetics in the range of 520 to 550 K, besides a peak with first order kinetics of more intensity around 607 K. The TL efficiency of the non doped sample is bigger than the doped with nitrogen; however the LOE efficiency is similar in both samples. The results indicate that the CVD diamond possesses excellent perspectives for dosimetric applications, with special importance in radiotherapy due to it is biologically compatible with the human tissue. (Author)

  5. Phytotoxicity of thallium (Tl) in culture solution. Pt. 1. Effects of Tl(I) on the growth and heavy metal contents of pea and field bean plants

    Energy Technology Data Exchange (ETDEWEB)

    Poetsch, U; Austenfeld, F A

    1985-01-01

    The effects of TlNO/sub 3/ and Tl(I)EDTA on growth and heavy metal contents of pea plants and field bean plants were compared in hydroponic culture experiments. In the presence of TlNO/sub 3/, the essential heavy metals were available to the plants in their ionic forms. When Tl(I)EDTA was present the essential heavy metals were available as chelated complexes. With increasing concentration of TlNO/sub 3/ dry matter production of pea plants was lowered and the Tl content of each organ was increased. The highest Tl content was found within the stems. The increased Tl contents were accompanied by depressed Mn, Zn, and Cu contents of the roots and depressed Mn contents of the stems, but increased Fe contents of the stems. Substitution of TlNO/sub 3/ by Tl(I)EDTA resulted in a stronger growth inhibition of the pea plants, and higher Tl contents of each organ. The highest Tl content was found within the stems. Tl(I)EDTA depressed Mn in the roots, but increased Fe and Mn in the stems, and Fe, Zn and Cu in the leaves. The increases may due to concentration by growth inhibition. The growth of the field bean was not effected by TlNO/sub 3/ nor by Tl(I)EDTA. The field bean contained most of the Tl within the roots and translocated only relatively small amounts to the shoots. This pattern was independent of the Tl compound. Increasing concentrations of TlNO/sub 3/ resulted in depressed Mn and Zn contents of the roots, and Mn contents of the stems. Chelation of Tl(I) resulted in a decrease of the Tl content of each organ. Tl(I)EDTA depressed only the Mn content of the roots.

  6. Determination of relative efficiency of a detector using Monte Carlo method

    International Nuclear Information System (INIS)

    Medeiros, M.P.C.; Rebello, W.F.; Lopes, J.M.; Silva, A.X.

    2015-01-01

    High-purity germanium detectors (HPGe) are mandatory tools for spectrometry because of their excellent energy resolution. The efficiency of such detectors, quoted in the list of specifications by the manufacturer, frequently refers to the relative full-energy peak efficiency, related to the absolute full-energy peak efficiency of a 7.6 cm x 7.6 cm (diameter x height) NaI(Tl) crystal, based on the 1.33 MeV peak of a 60 Co source positioned 25 cm from the detector. In this study, we used MCNPX code to simulate an HPGe detector (Canberra GC3020), from Real-Time Neutrongraphy Laboratory of UFRJ, to survey the spectrum of a 60 Co source located 25 cm from the detector in order to calculate and confirm the efficiency declared by the manufacturer. Agreement between experimental and simulated data was achieved. The model under development will be used for calculating and comparison purposes with the detector calibration curve from software Genie2000™, also serving as a reference for future studies. (author)

  7. TL1A regulates TCRγδ+ intraepithelial lymphocytes and gut microbial composition

    DEFF Research Database (Denmark)

    Tougaard, Peter; Skov, S.; Pedersen, A. E.

    2015-01-01

    TL1A is a proinflammatory cytokine, which is prevalent in the gut. High TL1A concentrations are present in patients with inflammatory bowel disease (IBD) and in IBD mouse models. However, the role of TL1A during steady‐state conditions is relatively unknown. Here, we used TL1A knockout (KO) mice ...

  8. Tl Cuprate Superconductors Studied by XPS

    Energy Technology Data Exchange (ETDEWEB)

    Vasquez, R. P. [Jet Propulsion Laboratory, California Institute of Technology, Pasadena, CA 91109-8099 (United States); Siegal, M. P. [Sandia National Laboratories, Albuquerque, NM 87185-1421 (United States); Overmyer, D. L. [Sandia National Laboratories, Albuquerque, NM 87185-1421 (United States); Ren, Z. F. [Department of Chemistry, State University of New York, Buffalo, NY 14260-3000 (United States); Lao, J. Y. [Department of Chemistry, State University of New York, Buffalo, NY 14260-3000 (United States); Wang, J. H. [Department of Chemistry, State University of New York, Buffalo, NY 14260-3000 (United States)

    1999-07-01

    XPS measurements on epitaxial thin films of the Tl cuprate superconductors Tl2Ba2CaCu2O8, Tl2Ba2Ca2Cu3O10, and Tl0.78Bi0.22Ba0.4Sr1.6Ca2Cu3O9-{delta} are presented. These data, together with previous measurements in this lab on Tl2Ba2CuO6-{delta} and TlBa2CaCu2O7-{delta}, comprise a comprehensive data set for comparison of Tl cuprates in which the number of Tl-O and Cu-O layers, and hence the chemical and electronic properties, vary. (c) 2000 American Vacuum Society.

  9. Tl Cuprate Superconductors Studied by XPS

    International Nuclear Information System (INIS)

    Vasquez, R. P.; Siegal, M. P.; Overmyer, D. L.; Ren, Z. F.; Lao, J. Y.; Wang, J. H.

    1999-01-01

    XPS measurements on epitaxial thin films of the Tl cuprate superconductors Tl2Ba2CaCu2O8, Tl2Ba2Ca2Cu3O10, and Tl0.78Bi0.22Ba0.4Sr1.6Ca2Cu3O9-δ are presented. These data, together with previous measurements in this lab on Tl2Ba2CuO6-δ and TlBa2CaCu2O7-δ, comprise a comprehensive data set for comparison of Tl cuprates in which the number of Tl-O and Cu-O layers, and hence the chemical and electronic properties, vary. (c) 2000 American Vacuum Society

  10. Comparison of TL profiles in recent sea cores

    Energy Technology Data Exchange (ETDEWEB)

    Castagnoli, G C; Bonino, G

    1985-01-01

    The thermoluminescence (TL) profile of different recent Tyrrhenian sea cores sampled at various intervals during the last centuries have been compared in order to check the reproducibility of the profiles and investigate the possibility of using the results for monitoring solar-terrestrial relations in the past. The satisfactory results obtained by comparison of two different cores in the time interval 1755-1969 A.D. has demonstrated: (a) the two TL profiles are correlated; (b) the 11 yr cycle corresponding to the main solar cycle is evident in both TL profiles.

  11. NaI(Tl) response functions

    International Nuclear Information System (INIS)

    Vega C, H. R.; Ortiz R, J. M.; Benites R, J. L.; De Leon M, H. A.

    2015-09-01

    The response functions of a NaI(Tl) detector have been estimated using Monte Carlo methods. Response functions were calculated for monoenergetic photon sources (0.05 to 3 MeV). Responses were calculated for point-like sources and for sources distributed in Portland cement cylinders. The responses were used to calculate the efficiency functions in term of photon energy. Commonly, sources used for calibration are point-like, and eventually sources to be measured have different features. In order to use the calibrated sources corrections due to solid angle, self-absorption and scattering, must be carried out. However, some of these corrections are not easy to perform. In this work, the calculated responses were used to estimate the detector efficiency of point-like sources, and sources distributed in Portland type cement. Samples of Portland paste were prepared and were exposed to photoneutrons produced by a 15 MV linac. Some of the elements in the cement were activated producing γ-emitting radionuclides that were measured with a NaI(Tl) gamma-ray spectrometer, that was calibrated with point-like sources. In order to determine the specific activity in the induced radioisotopes calculated efficiencies were used to make corrections due to the differences between the solid angle, photon absorption and photon scattering in the point-like calibration sources and the sources distributed in cement. During the interaction between photoneutrons and the cement samples three radioisotopes were induced: 56 Mn, 24 Na, and 28 Al. (Author)

  12. NaI(Tl) response functions

    Energy Technology Data Exchange (ETDEWEB)

    Vega C, H. R.; Ortiz R, J. M. [Universidad Autonoma de Zacatecas, Unidad Academica de Estudios Nucleares, Cipres No. 10, Fracc. La Penuela, 98068 Zacatecas, Zac. (Mexico); Benites R, J. L. [Centro Estatal de Cancerologia de Nayarit, Calz. de la Cruz 118 Sur, Tepic, Nayarit (Mexico); De Leon M, H. A., E-mail: fermineutron@yahoo.com.mx [Instituto Tecnologico de Aguascalientes, Av. Adolfo Lopez Mateos 1801 Ote., 20155 Aguascalientes, Ags. (Mexico)

    2015-09-15

    The response functions of a NaI(Tl) detector have been estimated using Monte Carlo methods. Response functions were calculated for monoenergetic photon sources (0.05 to 3 MeV). Responses were calculated for point-like sources and for sources distributed in Portland cement cylinders. The responses were used to calculate the efficiency functions in term of photon energy. Commonly, sources used for calibration are point-like, and eventually sources to be measured have different features. In order to use the calibrated sources corrections due to solid angle, self-absorption and scattering, must be carried out. However, some of these corrections are not easy to perform. In this work, the calculated responses were used to estimate the detector efficiency of point-like sources, and sources distributed in Portland type cement. Samples of Portland paste were prepared and were exposed to photoneutrons produced by a 15 MV linac. Some of the elements in the cement were activated producing γ-emitting radionuclides that were measured with a NaI(Tl) gamma-ray spectrometer, that was calibrated with point-like sources. In order to determine the specific activity in the induced radioisotopes calculated efficiencies were used to make corrections due to the differences between the solid angle, photon absorption and photon scattering in the point-like calibration sources and the sources distributed in cement. During the interaction between photoneutrons and the cement samples three radioisotopes were induced: {sup 56}Mn, {sup 24}Na, and {sup 28}Al. (Author)

  13. Studies on the tumor and organ affinity of /sup 201/Tl

    Energy Technology Data Exchange (ETDEWEB)

    Mori, H; Ando, I; Takeuchi, T [Kanazawa Univ. (Japan). School of Medicine; Ando, A; Hiraki, T

    1980-01-01

    In order to evaluate the tumor and organ affinity of /sup 201/Tl, using the Yoshida sarcoma bearing rats, the distribution of /sup 201/Tl/sup +/ in tissues and tumor was examined and compared to /sup 22/Na/sup +/, /sup 42/K/sup +/, /sup 86/Rb/sup +/, /sup 134/Cs/sup +/, and /sup 67/Ga-citrate. /sup 201/Tl/sup +/ showed almost same organ accumulation and kinetics as /sup 42/K/sup +/, /sup 86/Rb/sup +/, /sup 134/Cs, whereas /sup 201/Tl/sup +/ and /sup 22/Na/sup +/ had completely different organ distribution. These results suggest that organ affinity of /sup 201/Tl/sup +/ might be related to active transport, namely Na/sup +/-K/sup +/-ATPase pump mechanism as well as blood flow. However, it appeared to be taken into account the other factors such as different accumulation and clearance rate due to different substrates of organs. Kidney accumulation rate of /sup 201/Tl/sup +/ was much higher than /sup 42/K/sup +/, /sup 86/Rb/sup +/, /sup 134/Cs/sup +/ and about 10 times as /sup 42/K/sup +/. Macroautoradiograms of rat kidneys showed that /sup 201/Tl/sup +/ exhibited an initial high accumulation in the cortex and appeared in the outer cortex, as the cortex cleared of radioactivity. /sup 201/Tl might be interchangeable with K/sup +/ in the tubular system, reabsorbed with more affinity and cleared more slowly than K/sup +/. The tumor accumulation /sup 201/Tl/sup +/ might be related to Na/sup +/-K/sup +/-ATPase pump mechanism as well as other organs. However, in terms of tumor accumulation and concentration ratio to other organs, /sup 201/Tl/sup +/ was inferior to /sup 67/Ga-citrate, although the tumor to blood ratio was identical to that of /sup 67/Ga-citrate. Since /sup 201/Tl/sup + + +/ showed almost same distribution as /sup 201/Tl/sup +/, /sup 201/Tl/sup + + +/ might change into /sup 201/Tl/sup +/ in vivo.

  14. Study of method of efficiency transference using detectors NaI(Ti); Estudo de método de transferência de eficiência usando detectores NaI(Tl)

    Energy Technology Data Exchange (ETDEWEB)

    Ramos, Thiago L.; Salgado, César M., E-mail: thiago_lins-ramos@hotmail.com, E-mail: otero@ien.gov.br [Instituto de Engenharia Nuclear (IEN/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2017-07-01

    The use of NaI (Tl) scintillation detectors for measurements implies the determination of the detection efficiency as a function of the energy of the incident photons. The efficiency curve can be obtained experimentally with the use of several mono-energy sources calibrated with emission energies covering the whole range of interest or using the Monte Carlo method. The Institute of Nuclear Engineering develops several methodologies using these detectors as they are robust, inexpensive and do not need cooling for their use. The assembly of an experimental arrangement is usually complex, since several factors influence the result affecting reproducibility in measurements, such as: parallelism between source and detector, alignment between source and detector, and accuracy of source-detector distance. In view of such difficulties, an automated positioning system was developed for the source-detector set controlled by a micro controller based on the ARDUINO language in order to guarantee the reproducibility in the experimental arrangements. In the initial phase of this study, a mathematical model was developed in the MCNP-X code using a NaI (Tl) detector. A theoretical validation using the Efficiency Transfer Method was performed at three different positions on the detector's axial axis (10.6 cm, 11.3 cm and 12.0 cm). This method is based on the ratio of effective solid angles. The experimental validation presented maximum relative errors of 7.74% for the position 11.3 cm.

  15. (Tl, Sb) and (Tl, Bi) binary surface reconstructions on Ge(111) substrate

    Science.gov (United States)

    Gruznev, D. V.; Bondarenko, L. V.; Tupchaya, A. Y.; Yakovlev, A. A.; Mihalyuk, A. N.; Zotov, A. V.; Saranin, A. A.

    2018-03-01

    2D compounds made of Group-III and Group-V elements on the surface of silicon and germanium attract considerable attention due to prospects of creating III-V binary monolayers, which are predicted to hold advanced physical properties. In the present work, we have investigated two such systems, (Tl, Sb)/Ge(111) and (Tl, Bi)/Ge(111) using scanning tunneling microscopy, low energy electron diffraction observations and density-functional-theory calculations. In addition to the previously reported surface structures of 2D (Tl, Sb) and (Tl, Bi) compounds on Si(111), we found new ones, namely, √{ 7} × √{ 7} and 3 × 3. Formation processes and plausible models of their atomic arrangements are discussed.

  16. Trithallium tetraselenophosphate Tl3PSe4, and trithallium tetrathioarsenate, Tl3AsS4, by neutron time-of-flight diffraction

    International Nuclear Information System (INIS)

    Alkire, R.W.; Vergamini, P.J.; Larson, A.C.; Morosin, B.

    1984-01-01

    Room-temperature (293 K) single-crystal structure determinations of the isostructural materials Tl 3 PSe 4 and Tl 3 AsS 4 were performed at the Los Alamos National Laboratory Pulsed Neutron Facility. For Tl 3 PSe 4 : Msub(r) = 959.92, Pcmn, a = 9.276 (1), b = 11.036 (2), c = 9.058 (1) A, V = 927.27 A 3 , Z = 4, Dsub(m) = 6.87 (2), Dsub(x) = 6.876 Mg m -3 , lambdasub(neutron) = 0.5 → 5.2 A, F(000) = 252.5 fm. For Tl 3 AsS 4 : Msub(r) = 816.29, Pcmn, a = 9.084 (3), b = 10.877 (3), c = 8.877 (3) A, V = 877.11 A 3 , Z = 4, Dsub(m) = 6.18 (2), Dsub(x) = 6.181 Mg m -3 , lambdasub(neutron) = 0.5 → 5.2 A, F(000) = 177.2 fm. For Tl 3 PSe 4 (Tl 3 AsS 4 ), 1929 (1013) reflections were measured with I > 3sigma(I) and refined by full-matrix least squares to R(F) = 0.061 (0.063). Results on atomic refinement from this study represent an order of magnitude increase in precision over previous single-crystal X-ray structural work using Mo Kα radiation. The PSe 4 3- (AsS 4 3- ) groups have essentially tetrahedral configurations and one Tl + ion shows large anisotropic thermal motion which is structure related. (Auth.)

  17. Photon and neutron energy response of Thermoluminescent (TL) dosimeters

    International Nuclear Information System (INIS)

    Thilagam, L.; Priya, M.R.; Mohapatra, D.K.

    2018-01-01

    Theoretical Monte Carlo (MC) simulations are carried out to investigate the relative thermoluminesence (TL) response of the most commonly used TLD materials to a wide range of photon energy. The effect of polytetrafluoroethylene (PTFE) on TL response of CaSO 4 :Dy is also studied. Additionally, the neutron response of LiF:Mg,Ti TL materials with different concentrations of 6 Li is estimated in terms of the number of 6 Li(n, t) 4 He capture reactions for a wider neutron energy

  18. Isotopic exchange in a neutron-irradiated mixed-valence compound: Tl3(I) Tl(III)Cl6

    International Nuclear Information System (INIS)

    Fernandez Valverde, S.; Duplatre, G.

    1977-01-01

    The initial distribution of Tl(I) and Tl(III) species, and its change on heating, have been investigated in solid thermal neutron-irradiated Th 4 Cl 6 . An initial ratio of 5/1 for 204 Tl(I)/ 204 Tl(III) is found and this remains constant for integral gamma-doses of 3 to 12 MRad. The variation of the 204 Tl(III) fraction with temperature is found identical to that observed in labelled Tl 4 Cl 6 for which a genuine isotopic exchange has previously been described. It is concluded that the recoil species are rapidly converted, after the recoil processes, into stable ions

  19. Enhanced thermoelectric figure of merit in strained Tl-doped Bi2Se3

    KAUST Repository

    Saeed, Y.

    2014-07-21

    We explain recent experimental findings on Tl-doped Bi2Se3 by determining the electronic and transport properties by first-principles calculations and semi-classical Boltzmann theory. Though Tl-doping introduces a momentum-dependent spin-orbit splitting, the effective mass of the carriers is essentially not modified, while the band gap is reduced. Tl is found to be exceptional in this respect as other dopants modify the dispersion, which compromises thermoelectricity. Moreover, we demonstrate that only after Tl-doping strain becomes an efficient tool for enhancing the thermoelectric performance. A high figure of merit of 0.86 is obtained for strong p-doping (7 × 10^20 cm^(−3), maximal power factor) at 500 K under 2% tensile strain.

  20. Myocardial viability assessed by Tl-201 SPECT. Redistribution versus reinjection

    International Nuclear Information System (INIS)

    Chalela, William Azem; Pimentel, Flavio Ferrarini de Oliveira; Uchida, Augusto Hiroshi; Bottega, Augusto; Ramires, Jose Antonio Franchine; Izaki, Marisa; Moraes, Aguinaldo Pereira; Soares Junior, Jose; Giorgi, Maria C. Pinto; Moffa, Paulo Jorge; Bellotti, Giovanni; Giovanni Guido Cerri; Meneghetti, Jose Claudio

    1994-01-01

    The purpose of this study was to verify if a third series of images acquired by reinjection thallium-201, 24 h after conventional myocardial perfusion with the radioisotope, improves the identification of myocardial viability segments. The methods: we studied 30 patients, mean age 57.7 ±9.4 years, with old myocardial infarction using thallium (Tl)-201 SPECT, and we obtained three series of images (stress, redistribution after 4 h and reinjection after 24 h. Cardiac images were divided in 5 segments (apical, lateral, anterior, septal and inferior) and each one received a value by a score system according to the Tl-201 myocardial uptake (0=normal uptake; 1=mild hypoperfusion; 2=moderate hypoperfusion; 3=severe hypoperfusion or no myocardial uptake). We considered viable myocardium when the uptake of Tl-201 in the segment related to te myocardial infarction increases at least 1 point in two different axis of Tl-201 SPECT. The results: seven (23,3%) patients demonstrated increase of Tl-201 uptake only at reinjection images, showing a high efficacy of the method. Nine (30%) patients showed persistent hypoperfusion at all series of images suggesting only fibrosis in the are related to the infarction. Fourteen (46,7%) patients showed increase of Tl-201 concentration at redistribution images; among these patients, six showed improvement of myocardial uptake at reinjection. This condition was interpreted as regional chronic ischemic process: hibernating myocardium. The conclusion was that Tl-201 hypoperfusion at redistribution images without significant changes in relation to the stress images do not represent fibrosis at all. The reinjection technic was better than conventional redistribution in the detection of viable myocardium. This data allows a better therapeutic orientation. (author)

  1. Development of low background CsI(Tl) and NaI(Tl) crystals for WIMP search

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Hyun Su [Department of Physics, Ewha Womans University, Seoul 120-750 (Korea, Republic of)

    2015-08-17

    We have developed low background CsI(Tl) and NaI(Tl) crystals to search for weakly interacting massive particles as well as to verify the origin of the annual modulation signal observed by the DAMA/LIBRA experiment. Extensive studies about the contamination mechanisim of {sup 137}Cs in CsI powder lead to the growth of ultra-low-background CsI(Tl) crystals. Similar approaches for NaI(Tl) crystals have been applied to reduce internal backgrounds to less than 0.5 counts/kg/day/keV. Status and understanding of backgrounds and background reduction in NaI(Tl) crystals will be discussed.

  2. TL response to quartz and aluminum oxide grain for α-irradiation

    International Nuclear Information System (INIS)

    Pan Baolin; Wei Mingjian; Li Dongxu; Liu Zhaowen; Liu Chao; Zhao Shiyuan

    2009-01-01

    Thermoluminescence (TL) response for an α-ray irradiation system ( 241 Am) was examined with quartz grains of 11-40 μm. Quartz grains of different sizes, i.e. 137 Cs), before they were irradiated to different doses by the α-ray irradiation system. TL response to the quartz grain samples was measured. TL response of the quartz grains smaller than 4 μm and 11-40 μm to α-ray irradiation is the best, as the α-rays cannot penetrate quartz larger than 40 μm. The TL response characteristic is related with quartz grain surface area. TL responses to α-irradiation of 11-40 μm quartz and aluminum oxide grains were compared. The α-irradiation TL response of aluminum oxide (330 degree C) is better than the quartz (375 degree C). (authors)

  3. TL and LOE dosimetric evaluation of diamond films exposed to beta and ultraviolet radiation

    International Nuclear Information System (INIS)

    Preciado F, S.; Melendrez, R.; Chernov, V.; Barboza F, M.; Schreck, M.; Cruz Z, E.

    2005-01-01

    The diamond possesses a privileged position regarding other materials of great technological importance. Their applications go from the optics, microelectronics, metals industry, medicine and of course as dosemeter, in the registration and detection of ionizing and non ionizing radiation. In this work the results of TL/LOE obtained in two samples of diamond of 10 μm thickness grown by the chemical vapor deposition method (CVD) assisted by microwave plasma. The films were deposited in a silicon substrate (001) starting from a mixture of gases composed of CH 4 /H 2 and 750 ppm of molecular nitrogen as dopant. The samples were exposed to beta radiation (Sr 90 / Y 90 ) and ultraviolet, being stimulated later on thermal (TL) and optically (LOE) to evaluate their dosimetric properties. The sample without doping presented high response TL/LOE to the ultraviolet and beta radiation. The TL glow curve of the sample without doping showed two TL peaks with second order kinetics in the range of 520 to 550 K, besides a peak with first order kinetics of more intensity around 607 K. The TL efficiency of the non doped sample is bigger than the doped with nitrogen; however the LOE efficiency is similar in both samples. The results indicate that the CVD diamond possesses excellent perspectives for dosimetric applications, with special importance in radiotherapy due to it is biologically compatible with the human tissue. (Author)

  4. Quality control 201TlCl solution obtained at IPEN-CNEN/SP through the direct method of 201Tl preparation

    International Nuclear Information System (INIS)

    Fernandes, L.; Silva, C.P.G. da.

    1991-09-01

    The radiopharmaceutical 201 TlCl is used in Nuclear medicine for myocardial visualization. The solution of 201 TlCl was prepared using 201 Tl obtained by irradiating a natural mercury target with protons. This radionuclide was subjected to different quality control processes to verify the purity required for its use in Medicine. Some of these controls concerned the determination of 200 Tl, 201 Tl and 202 Tl; the chemical identification of 201 Tl +1 ; the hydrazine concentration, mercury contamination and the presence of phosphate. Furthermore, the biologic distribution in Wistar rats and tests for sterility, pyrogens and for toxicity were carried out. It was verified that the solution obtained was in the form of thallous chloride. This radiopharmaceutical can give a good heart image in animals but due to the contamination of 201 Tl with 200 Tl and 202 Tl its use in human beings is not possible unless enriched 202 Hg is used as target of irradiation. (author)

  5. Chemical bonding in Tl cuprates studied by x-ray photoemission

    International Nuclear Information System (INIS)

    Vasquez, R.P.; Siegal, M.P.; Overmyer, D.L.; Ren, Z.F.; Lao, J.Y.; Wang, J.H.

    1999-01-01

    Epitaxial thin films of the Tl cuprate superconductors Tl 2 Ba 2 CaCu 2 O 8 , Tl 2 Ba 2 Ca 2 Cu 3 O 10 , and Tl 0.78 Bi 0.22 Ba 0.4 Sr 1.6 Ca 2 Cu 3 O 9-δ are studied with x-ray photoemission spectroscopy. These data, together with previous measurements in this lab of Tl 2 Ba 2 CuO 6+δ and TlBa 2 CaCu 2 O 7-δ , comprise a comprehensive data set for a comparative study of Tl cuprates with a range of chemical and electronic properties. In the Cu 2p spectra, a larger energy separation between the satellite and main peaks (E s -E m ) and a lower intensity ratio (I s /I m ) are found to correlate with higher values of T c . Analysis of these spectra within a simple configuration interaction model suggests that higher values of T c are related to low values of the O 2p→Cu 3d charge transfer energy. In the O 1s region, a smaller bond length between Ba and Cu-O planar oxygen is found to correlate with a lower binding energy for the signal associated with Cu-O bonding, most likely resulting from the increased polarization screening by Ba 2+ ions. For samples near optimum doping, maximum T c is observed to occur when the Tl 4f 7/2 binding energy is near 117.9 eV, which is near the middle of the range of values observed for Tl cuprates. Higher Tl 4f 7/2 binding energies, corresponding to formal oxidation states nearer Tl 1+ , are also found to correlate with longer bond lengths between Ba and Tl-O planar oxygen, and with higher binding energies of the O 1s signal associated with Tl-O bonding. copyright 1999 The American Physical Society

  6. Natural quartz TL property and similarity in Piper nigrum L

    International Nuclear Information System (INIS)

    Guzman A, S.; Cruz Z, E.; Furetta, C.; Brown, F.; Barboza F, M.

    2009-10-01

    Quartz is a mineral abundant in nature and can provide information thermoluminescent (TL), and also is located in the mineral fraction of some herbs and spices consumed. It is present the analysis of the TL properties of a sample of natural quartz rock and compared with those obtained from the fraction of Piper nigrum L. poly mineral when they were exposed to 60 Co gamma radiation. The poly minerals of Piper nigrum L. were analyzed by X-ray diffraction, where the quartz was found as a major component. They separated in different particle sizes (10, 53, 74 and 149 μm). The samples were irradiated at relatively low doses (1-500 Gy) and high (0.1-40 kGy) in order to determine the linearity of the TL emission as a function of the dose and the analysis of glow curves. Also there was the fading of the TL signal, the effect of ultra violet light. The reproducibility of the TL signal in the samples indicates that a smaller particle size gives better TL signal. (author)

  7. Kinetic parameters and TL mechanism in cadmium tetra borate phosphor

    International Nuclear Information System (INIS)

    Annalakshmi, O.; Jose, M.T.; Sridevi, J.; Venkatraman, B.; Amarendra, G.; Mandal, A.B.

    2014-01-01

    Polycrystalline powder samples of cadmium tetra borate were synthesized by a simple solid state sintering technique and gamma irradiated sample showed a simple Thermoluminescence (TL) glow peak around 460 K. The TL kinetic parameters of gamma irradiated phosphor were determined by initial rise (IR), isothermal decay (ID), peak shape (PS), variable heating rate (VHR) and glow curve de-convolution method. The kinetic parameters such as activation energy (E), frequency factor (s) and order of kinetics (b) were calculated by IR, ID, PS and VHR methods are in the order of ∼1.05 eV, 10 9 –10 12 s −1 and 1.58, respectively. From the results of TL and PL emission studies carried out on the phosphor revealed that the defect centers related to TL is different from that for PL. EPR measurements were carried out to identify the defect centers formed in cadmium tetra borate phosphor on gamma irradiation. Based on EPR studies the mechanism for TL process in cadmium tetra borate is proposed in this paper -- Highlights: • Polycrystalline powder samples of undoped cadmium tetra borate synthesized. • Cadmium tetra borate phosphor exhibits a dosimetric peak at 458 K. • Kinetic parameters of the trap responsible for TL evaluated. • TL mechanism is proposed from TL to EPR correlation studies

  8. Kinetic parameters and TL mechanism in cadmium tetra borate phosphor

    Energy Technology Data Exchange (ETDEWEB)

    Annalakshmi, O. [Radiological Safety Division, Materials Physics Division, Indira Gandhi Centre for Atomic Research, Kalpakkam-603102 (India); Jose, M.T., E-mail: mtj@igcar.gov.in [Radiological Safety Division, Materials Physics Division, Indira Gandhi Centre for Atomic Research, Kalpakkam-603102 (India); Sridevi, J. [Central Leather Research Institute, Council of Scientific and Industrial Research, Chennai 600 020, Tamilnadhu (India); Venkatraman, B. [Radiological Safety Division, Materials Physics Division, Indira Gandhi Centre for Atomic Research, Kalpakkam-603102 (India); Amarendra, G. [Materials Physics Division, Indira Gandhi Centre for Atomic Research, Kalpakkam-603102 (India); Mandal, A.B. [Central Leather Research Institute, Council of Scientific and Industrial Research, Chennai 600 020, Tamilnadhu (India)

    2014-03-15

    Polycrystalline powder samples of cadmium tetra borate were synthesized by a simple solid state sintering technique and gamma irradiated sample showed a simple Thermoluminescence (TL) glow peak around 460 K. The TL kinetic parameters of gamma irradiated phosphor were determined by initial rise (IR), isothermal decay (ID), peak shape (PS), variable heating rate (VHR) and glow curve de-convolution method. The kinetic parameters such as activation energy (E), frequency factor (s) and order of kinetics (b) were calculated by IR, ID, PS and VHR methods are in the order of ∼1.05 eV, 10{sup 9}–10{sup 12} s{sup −1} and 1.58, respectively. From the results of TL and PL emission studies carried out on the phosphor revealed that the defect centers related to TL is different from that for PL. EPR measurements were carried out to identify the defect centers formed in cadmium tetra borate phosphor on gamma irradiation. Based on EPR studies the mechanism for TL process in cadmium tetra borate is proposed in this paper -- Highlights: • Polycrystalline powder samples of undoped cadmium tetra borate synthesized. • Cadmium tetra borate phosphor exhibits a dosimetric peak at 458 K. • Kinetic parameters of the trap responsible for TL evaluated. • TL mechanism is proposed from TL to EPR correlation studies.

  9. 207Pb and 205Tl NMR on Perovskite Type Crystals APbX3 (A = Cs, Tl, X = Br, I)

    Science.gov (United States)

    Sharma, Surendra; Weiden, Norbert; Weiss, Alarich

    1987-11-01

    By 205Tl and 207Pb NM R the chemical shift in polycrystalline samples of binary halides AX, BX2 and ternary halides ABX3 (A = Cs, Tl; B = Pb; X = Br, I) was studied at room temperature. The chemical shift tensors δ ( 205Tl) and δ (207Pb) were determined in magnitude and orientation on single crystals of the orthorhombic TlPbI3. The components of the δ(205Tl) tensor are δx (205Tl) || a = 611ppm; δy (205Tl) || b = 680 ppm; δZ(205Tl) || c = 1329 ppm; δiso(205Tl) = 873.3 ppm (with respect to 3.4 molar aqueous solution of TlOOCCH3). The chemical shift tensor of 207Pb in TlPbI3 shows two orientations. One of them is: δx (207Pb) = 3760 ppm, inclined 30° from b towards c, δy(207Pb) || a = 3485 ppm, δz(207Pb) = 2639 ppm inclined 120° from b towards c. δiso(207Pb) = 3295 ppm (with respect to saturated aqueous solution of Pb(NO3)2). The results are discussed with respect to the crystal structure and a model to explain orientation and anisotropy of the tensors δ(205Tl) and δ(207Pb) in TlPbI3 is proposed. In the system CsPbBr3-x Ix δ(207Pb) was studied on polycrystalline samples. The chemical shift increases with increasing x and negative excess shift is observed.

  10. Relative thermoluminescent efficiencies proton/gamma and helium/gamma of peaks of high temperature in TLD-100 dosemeters; Eficiencias termoluminiscentes relativas proton/gamma y helio/gamma de picos de alta temperatura en dosimetros TLD-100

    Energy Technology Data Exchange (ETDEWEB)

    Flores M, E. [UNAM, Facultad de Ciencias, 04510 Mexico D.F. (Mexico)

    2007-07-01

    The increase of the applications of ion beams in radiotherapy treatments has generated interest in the study of the thermoluminescent materials (TL) that allow to determine the applied doses. A way to quantify the TL response from these materials to ions is by means of the relative thermoluminescent efficiency. In the group of Thermoluminescent dosimetry of the Institute of Physics of the UNAM (IFUNAM) the thermoluminescent response of the TLD-100 dosemeters has been studied, which present a glow curve characteristic with several peaks that correspond to traps and luminescent centers in the material. The stable peaks know each other as 4, 5, 6a, 6b, 7, 8, 9 and 10. The efficiencies should be measured using the response so much to the radiation of interest (in this case protons and helium ions) as the response to gamma radiation. In previous works with ions of low energy taken place in the Pelletron accelerator of the IFUNAM was only measured the TL efficiency for the peak 5 and the total signal. It had not been possible to measure the efficiency of the peaks of high temperature (6a-10) because, for the gamma radiation, the peaks of high temperature show very small signals; however, recently Massillon carries out measures of efficiency TL of peaks of high temperature for ions of intermediate energy using a protocol special of reading and of deconvolution that allows to measure the signals coming from the peaks of high temperature. In this work is implemented this same protocol to complete the study of TL efficiencies at low energy of protons and helium and to determine if the values of efficiency depend on the used reading protocol. For it is reported it measures of the relative efficiency of the peaks of high temperature from the TLD-100 exposed to protons of 1.5 MeV and nuclei of helium of 3 and 7.5 MeV. (Author)

  11. How Experienced SoTL Researchers Develop the Credibility of Their Work

    Directory of Open Access Journals (Sweden)

    Jennie Billot

    2017-03-01

    Full Text Available Teaching and learning research in higher education, often referred to as the Scholarship of Teaching and Learning (SoTL, is still relatively novel in many academic contexts compared to the mainstay of disciplinary research. One indication of this is the challenges those who engage in SoTL report in terms of how this work is valued or considered credible amongst disciplinary colleagues and in the face of institutional policies and practices. This paper moves beyond the literature that describes these specific challenges to investigate how 23 experienced SoTL researchers from five different countries understood the notion of credibility in relationship to their SoTL research and how they went about developing credibility for their work. Semi-structured interviews were facilitated and analyzed using inductive analysis. Findings indicate that notions of credibility encompassed putting SoTL research into action and building capacity and community around research findings, as well as gaining external validation through traditional indicators such as publishing. SoTL researchers reported a variety of strategies and approaches they were using, both formal and informal, to develop credibility for their work. The direct focus of this paper on credibility of SoTL work as perceived by experienced SoTL researchers, and how they go about developing credibility, is a distinct contribution to the discussions about the valuing of SoTL work.

  12. Thallium (Tl) sorption onto illite and smectite: Implications for Tl mobility in the environment

    Science.gov (United States)

    Martin, Loïc A.; Wissocq, Aubéry; Benedetti, M. F.; Latrille, Christelle

    2018-06-01

    Clay minerals play a relevant role in the transport and fate of trace elements in the environment. Though illite has been referred as an important Thallium (Tl) bearing phase in soils, mechanisms and affinity of thallium for clay minerals remain poorly known. This study investigated the sorption behavior of thallium as Tl(I) onto illite and smectite, two clay minerals occurring mainly in soils and sediments. Different sorption experiments were carried out under various pH conditions and Tl concentrations, in competition with sodium and calcium at a constant ionic strength of 0.01 mol L-1. Our results showed that illite displayed more affinity than smectite for thallium. With illite, the distribution coefficients (Kd in L kg-1) varied between 102.75 ± 0.17 and 104.0 ± 0.17 in Na solutions versus between 102.25 ± 0.17 and 103.0 ± 0.17 in Ca solutions, depending on pH. With smectite, Kd (in L kg-1) ranged between 102.50 ± 0.16 and 103.20 ± 0.16 and between 101.25 ± 0.16 and 101.95 ± 0.16 in Na and Ca solutions, respectively. Sorption behavior was described with the Multi-Site Ion Exchanger model and selectivity coefficients with respect to protons were calculated for the first time. In all cases, independently of clay mineral and background electrolyte, low capacity but highly reactive sites were dominant in thallium uptake, highlighting Tl affinity for those sites. Moreover, the exchangeable and reversible interactions between Tl+ and clays reactive sites suggested that in changing conditions, thallium could be released in solution. The role of clay minerals in thallium environmental cycle is evident and confirmed illite to be a dominant Tl bearing phase, in some environment competing with manganese oxides. Compared to others Tl bearing mineral phases, clays are ranked as follows: MnO2 > illite > smectite ∼ ferrihydrite ≥ Al2O3 ∼ goethite > SiO2. Finally, over the three monovalent cations (Tl, Rb, Cs) Tl is the one less sorbed on illite independently of

  13. A preliminary study of landslide gouge dating by TL technique

    Energy Technology Data Exchange (ETDEWEB)

    Fengju, Ji; Jianping, Li [Inst. of Geology, National Seismological Bereau, Beijing (China); Mingda, Liu [Inst. of Crustal Dynamics, SSB, Beijing (China)

    1993-04-01

    The key to date slipping of landslide by TL method is whether the temperature and pressure caused by slipping can lead the original TL to 'zero'for some minerals within the slipping band. For this purpose, the simulated experiments under different temperature-pressure were made and the TL annealing effect of landslide gouge was studied. The results show that the frictional heating caused during slipping is a main factor leading the mineral's TL to decrease on the slip plane and that increment of temperature is in close relation with strength of shear stress, thickness of landslide gouge and amount of displacement. As an example, the slipping age of a paleo-landslide at Huangtupo, Hubei Province, has been dated to be about 140 ka.

  14. Chemical Bonding in Tl Cuprates Studied by X-Ray Photoemission

    Energy Technology Data Exchange (ETDEWEB)

    Lao, J.Y.; Overmyer, D.L.; Ren, Z.F.; Siegal, M.P.; Vasquez, R.P.; Wang, J.H.

    1999-04-05

    Epitaxial thin films of the Tl cuprate superconductors Tl{sub 2}Ba{sub 2}CaCu{sub 2}O{sub 8}, Tl{sub 2}Ba{sub 2}Ca{sub 2}Cu{sub 3}O{sub 10}, and TL{sub 0.78}Bi{sub 0.22}Ba{sub 0.4}Sr{sub 1.6}Ca{sub 2}Cu{sub 3}O{sub 9{minus}{delta}} are studied with x-ray photoemission spectroscopy. These data, together with previous measurements in this lab of Tl{sub 2}Ba{sub 2}CuO{sub 6+{delta}} and TlBa{sub 2}CaCu{sub 2}O{sub 7{minus}{delta}}, comprise a comprehensive data set for a comparative study of Tl cuprates with a range of chemical and electronic properties. In the Cu 2p spectra, a larger energy separation between the satellite and main peaks (E{sub s}-E{sub m}) and a lower intensity ratio (I{sub s}/I{sub m}) are found to correlate with higher values of T{sub c}. Analysis of these spectra within a simple configuration interaction model suggests that higher values of T{sub c} are related to low values of the O 2p {r_arrow} Cu 3d charge transfer energy. In the O 1s region, a smaller bond length between Ba and Cu-O planar oxygen is found to correlate with a lower binding energy for the signal associated with Cu-O bonding, most likely resulting from the increased polarization screening by Ba{sup 2+} ions. For samples near optimum doping, maximum T{sub c} is observed to occur when the Tl 4f{sub 7/2} binding energy is near 117.9 eV, which is near the middle of the range of values observed for Tl cuprates. Higher Tl 4f{sub 7/2} binding energies, corresponding to formal oxidation states nearer Tl{sup 1+}, are also found to correlate with longer bond lengths between Ba and Tl-O planar oxygen, and with higher binding energies of the O 1s signal associated with Tl-O bonding.

  15. Chemical bonding in Tl cuprates studied by x-ray photoemission

    Energy Technology Data Exchange (ETDEWEB)

    Vasquez, R.P. [Center for Space Microelectronics Technology, Jet Propulsion Laboratory, California Institute of Technology, Pasadena, California 91109-8099 (United States); Siegal, M.P.; Overmyer, D.L. [Sandia National Laboratories, Albuquerque, New Mexico 87185-1421 (United States); Ren, Z.F.; Lao, J.Y.; Wang, J.H. [Materials Synthesis Laboratory, Department of Chemistry, State University of New York, Buffalo, New York 14260-3000 (United States)

    1999-08-01

    Epitaxial thin films of the Tl cuprate superconductors Tl{sub 2}Ba{sub 2}CaCu{sub 2}O{sub 8}, Tl{sub 2}Ba{sub 2}Ca{sub 2}Cu{sub 3}O{sub 10}, and Tl{sub 0.78}Bi{sub 0.22}Ba{sub 0.4}Sr{sub 1.6}Ca{sub 2}Cu{sub 3}O{sub 9{minus}{delta}} are studied with x-ray photoemission spectroscopy. These data, together with previous measurements in this lab of Tl{sub 2}Ba{sub 2}CuO{sub 6+{delta}} and TlBa{sub 2}CaCu{sub 2}O{sub 7{minus}{delta}}, comprise a comprehensive data set for a comparative study of Tl cuprates with a range of chemical and electronic properties. In the Cu 2p spectra, a larger energy separation between the satellite and main peaks (E{sub s}{minus}E{sub m}) and a lower intensity ratio (I{sub s}/I{sub m}) are found to correlate with higher values of T{sub c}. Analysis of these spectra within a simple configuration interaction model suggests that higher values of T{sub c} are related to low values of the O&hthinsp;2p{r_arrow}Cu&hthinsp;3d charge transfer energy. In the O&hthinsp;1s region, a smaller bond length between Ba and Cu-O planar oxygen is found to correlate with a lower binding energy for the signal associated with Cu-O bonding, most likely resulting from the increased polarization screening by Ba{sup 2+} ions. For samples near optimum doping, maximum T{sub c} is observed to occur when the Tl 4f{sub 7/2} binding energy is near 117.9 eV, which is near the middle of the range of values observed for Tl cuprates. Higher Tl&hthinsp;4f{sub 7/2} binding energies, corresponding to formal oxidation states nearer Tl{sup 1+}, are also found to correlate with longer bond lengths between Ba and Tl-O planar oxygen, and with higher binding energies of the O&hthinsp;1s signal associated with Tl-O bonding. {copyright} {ital 1999} {ital The American Physical Society}

  16. Quality control of the solution sup(201)TlCl obtained at IPEN-CNEN/SP by sup(201)Tl direct preparation

    International Nuclear Information System (INIS)

    Fernandes, L.; Silva, C.P.G. da

    1991-01-01

    The radiopharmaceutical sup(201) TlCl is used in Nuclear Medicine for myocardial visualization. The solution of sup(201)TlCl was prepared using sup(201)Tl obtained by irradiating a natural mercury target with protons. This radionuclide was subjected to different quality control processes to verify the purity required for its use in Medicine. Some of these controls concerned the determination of sup(200)Tl, sup(201)Tl and sup(202)Tl; the chemical identification of sup(201)Tl sup(+1); the hydrazine concentration, mercury contamination and the presence of phosphate. Furthermore, the biologic distribution in Wistar rats and tests for sterility pyrogens and for toxicity were carried out. It was verified that the solution obtained was in the form of tallous chloride. This radiopharmaceutical can give a good heart image in animals but due to the contamination of sup(201)Tl with sup(200)Tl and sup(202)Tl its use in human beings is not possible unless enriched sup(202)Hg is used as target of irradiation. (author)

  17. Prolate yrast cascade in 183Tl

    International Nuclear Information System (INIS)

    Reviol, W.; Carpenter, M. P.; Janssens, R. V. F.; Jenkins, D.; Toth, K. S.; Bingham, C. R.; Riedinger, L. L.; Weintraub, W.; Cizewski, J. A.; Lauritsen, T.

    2000-01-01

    The yrast sequence in 183 Tl has been studied for the first time in recoil-mass selected γ-ray spectroscopic measurements. A rotational-like cascade of seven transitions is established down to the band head with probable spin and parity (13/2 + ). Unlike in the adjacent odd-mass Tl nuclei, prompt γ decay from the yrast band to a lower lying weakly deformed (oblate) structure is not observed. These features are consistent with the predicted drop of the prolate band head in 183 Tl compared to 185 Tl. The implications for the prolate energy minimum in odd-mass Tl nuclei at the neutron i 13/2 midshell (N=103) are discussed. (c) 2000 The American Physical Society

  18. Development of surgical gamma probes with TlBr semiconductors and CsI(Tl) scintillators crystals

    International Nuclear Information System (INIS)

    Costa, Fabio Eduardo da

    2006-01-01

    Radio guided surgery, using probes with radiation detectors, has been prominence in the medical area in the last decade. This technique consists in injecting a radioactive substance to concentrate in tumour and assist the localization during the surgical procedure. The radio guided surgeries allowing the identification of lymph node has revolutioned the behavior of tumour in initial stadium when are being spread by lymphatic way. The conditions imposed to the surgery due the proximity between some lymph nodes, demands of the probes, a small diameters and capacity of individual identification of these lymph nodes radiolabelled by a specific tracer. The international market supplies these probes with CdTe semiconductors and scintillators, but there is some time lack a promptly technical assistance in the Brazilian market. This work developed probes with national technology, using CsI(Tl) scintillators crystals and, in substitution to CdTe crystals semiconductors, the TlBr crystal, that is a new semiconductor detector in a world-wide development, with advantages in relation to the CdTe. Both crystals have been grown in IPEN. All the necessary electronics, specially, the preamplifier, that was also a restrictive factor for development of these types of probe in the country, have been developed with components found in the national market. Systematic measures of spatial resolution, spatial selectivity, maximum sensitivity and quality of the shielding have been carried the probes development. The results have shown that the probes, one with the CsI(Tl) crystal and another with TlBr semiconductor presented the requested performance in the international literature for radio guided probes. (author)

  19. Tl, Bi, and Pb doping in Ba4BiPb2TlO12-δ

    International Nuclear Information System (INIS)

    Sutto, T.E.; Averill, B.A.

    1992-01-01

    To determine the effects of different 6s metal concentrations on the superconducting nature of Ba 4 BiPb 2 TlO 12-δ , materials produced via four doping schemes were examined: Ba 4 Bi(Pb, Tl) 3 O 12-δ , Ba 4 -(BiPb) 3 TlO 12-δ , Ba 4 (Bi,Tl) 2 Pb 2 O 12-δ , and Ba 4 Bi x Pb 4-2x Tl x O 12-δ . For the parent compound a value of δ = 0.91 was observed, indicating that approximately 1/4 oxygen atom was missing per cubic subsection of the unit cell. For all samples, the symmetry of the parent compound changed from orthorhombic to tetragonal as the system moved away from the ideal composition. This was usually accompanied by the loss of superconductivity, which exhibited a maximum T c of 10.5 K for the parent compound Ba 4 BiPb 2 TlO 12-δ . Also reported are high-temperature magnetic susceptibility results, which are used to determine the effect of metal substitution on the density of states at the Fermi level. For each set of variants on the parent composition, the onset of superconductivity was accompanied by a significant decrease in the size of the Pauli paramagnetic signal. 16 refs., 6 figs

  20. Development of tailor-made silica fibres for TL dosimetry

    International Nuclear Information System (INIS)

    Bradley, D.A.; Abdul Sani, Siti F.; Alalawi, Amani I.; Jafari, S.M.; Noor, Noramaliza M.; Hairul Azhar, A.R.; Mahdiraji, Ghafour Amouzad; Tamchek, Nizam; Ghosh, S.; Paul, M.C.; Alzimami, Khalid S.; Nisbet, A.; Maah, M.J.

    2014-01-01

    The Ge dopant in commercially available silica optical fibres gives rise to appreciable thermoluminscence (TL), weight-for-weight offering sensitivity to MV X-rays several times that of the LiF dosimeter TLD100. The response of these fibres to UV radiation, X-rays, electrons, protons, neutrons and alpha particles, with doses from a fraction of 1 Gy up to 10 kGy, have stimulated further investigation of the magnitude of the TL signal for intrinsic and doped SiO 2 fibres. We represent a consortium effort between Malaysian partners and the University of Surrey, aimed at production of silica fibres with specific TL dosimetry applications, utilizing modified chemical vapour deposition (MCVD) doped silica–glass production and fibre-pulling facilities. The work is informed by defect and dopant concentration and various production dependences including pulling parameters such as temperature, speed and tension; the fibres also provide for spatial resolutions down to <10 µm, confronting many limitations faced in use of conventional (TL) dosimetry. Early results are shown for high spatial resolution (∼0.1 mm) single-core Ge-doped TL sensors, suited to radiotherapy applications. Preliminary results are also shown for undoped flat optical fibres of mm dimensions and Ge-B doped flat optical fibres of sub-mm dimensions, with potential for measurement of doses in medical diagnostic applications. - Highlights: • Optical fibres tailor-made for TL dosimetry. • Sensitive to diagnostic as well as therapy doses in medicine. • Preform and fibre pulling facilities. • Relative TL and EPR measurements

  1. Measurements of environmental gamma-ray spectra using a multi-element TL dosemeter

    International Nuclear Information System (INIS)

    Furuta, Sadaaki; Boetter-Jensen, L.; Nielsen, S.P.

    1986-12-01

    A method to estimate the energy distribution and dose of environmental gamma radiation was developed using a multielement TL dosemeter. Experimentally obtained energy responses from a multi-element TL dosemeter with different kinds of filters were used to calculate the energy distribution and related dose by the SAND-II computer code. The code was originally developed to estimate the neutron flux using a multiple foil activation method. Measurements were made at several locations with the multi-element TL dosemeter and comparisons were made with results from a NaI(Tl) scintillation detector and a high-pressure ionization chamber. (author)

  2. Study on the effect of deposition rate and concentration of Eu on the fluorescent lifetime of CsI: Tl thin film

    Energy Technology Data Exchange (ETDEWEB)

    Xie, Yijun; Guo, Lina [University of Electronic Science and Technology of China, State Key Laboratory of Electronic Thin Films and Integrated Devices, School of Optoelectronic Information, Chengdu 610054 (China); Liu, Shuang, E-mail: shuangliu@uestc.edu.cn [University of Electronic Science and Technology of China, State Key Laboratory of Electronic Thin Films and Integrated Devices, School of Optoelectronic Information, Chengdu 610054 (China); Wang, Qianfeng; Zhang, Shangjian; Liu, Yong [University of Electronic Science and Technology of China, State Key Laboratory of Electronic Thin Films and Integrated Devices, School of Optoelectronic Information, Chengdu 610054 (China); Zhong, Zhiyong [University of Electronic Science and Technology of China, State Key Laboratory of Electronic Thin Films and Integrated Devices, Chengdu 610054 (China)

    2017-06-21

    Although there are many new scintillators being developed recently, CsI: Tl is still very efficient among them. The fluorescent lifetime is a very important parameter of CsI: Tl thin film and two series of experiments have been conducted to learn about it. Our experiments, however, have demonstrated that the deposition rate and the codoping of Eu{sup 2+} will significantly influence its fluorescent lifetime. In order to increase the efficiency of the imaging system, we intend to obtain a higher fluorescent lifetime for CsI: Tl thin film by controlling these two conditions. - Highlights: • We used vacuum vapor deposition method to grow the high-quality thin films. • The relationship between the deposition rate and the fluorescent lifetime of CsI: Tl thin film was tested. • Concentration of Eu on fluorescent lifetime of the CsI: Tl thin film was studied.

  3. Real-time in-situ monitoring of the topotactic transformation of TlCu3Se2 into TlCu2Se2

    International Nuclear Information System (INIS)

    Ångström, J.; Sahlberg, M.; Berger, R.

    2015-01-01

    Highlights: • Topotactic transition from TlCu 3 Se 2 to TlCu 2 Se 2 followed in situ. • Synchrotron radiation X-ray powder diffraction enabled short scans. • Relative abundance of phases refined from powder data. • Opens up for studying similar systems in the same manner. - Abstract: The solid state transformation of monoclinic TlCu 3 Se 2 into tetragonal TlCu 2 Se 2 by oxidative copper leaching in concentrated ammonia solution has been studied in situ by the use of synchrotron radiation. The diffraction patterns of parent and daughter phase are both sharp, indicating a strong topotactic relationship between them that effectuates a rapid change by “chimie douce” performed at +19 °C. The transformation rate is strongly connected to the access of oxygen from the surrounding air. The transformation was followed in a real-time mode, being almost complete after 2.5 h with 1 h incubation due to low oxygen content, as shown from refining the diffraction patterns by Rietveld profile technique

  4. Activation analysis of thallium in urine using the 203Tl(n,2n) 202Tl reaction

    International Nuclear Information System (INIS)

    Korob, R.O.; Cohen, I.M.; Lage, M.; Baro, G.B.

    1976-04-01

    The method developed by the authors of thallium determination in human urine, based on the 203 Tl(n,2n) 202 Tl reaction followed by chemical separation and measurement of the produced 202 Tl by gamma spectrometry, is described. Its application in some cases of intoxication by thallium is reported. The advantages and limitations of the described technique are discussed. (author) [es

  5. Thermal and x-ray studies on Tl2U(MoO4)3 and Tl4U(MoO4)4

    International Nuclear Information System (INIS)

    Dahale, N.D.; Keskar, Meera; Kulkarni, N.K.; Singh Mudher, K.D.

    2006-01-01

    In the quaternary Tl-U(IV)-Mo-O system, two new compounds namely Tl 2 U(MoO 4 ) 3 and Tl 4 U(MoO 4 ) 4 were prepared and characterized by powder X-ray diffraction and thermal methods. These compounds were prepared by solid state reactions of Tl 2 MoO 4 , UMoO 5 and MoO 3 in the required stoichiometric ratio at 500 deg C in evacuated sealed quartz ampoule. The XRD data of Tl 2 U(MoO 4 ) 3 and Tl 4 U(MoO 4 ) 4 were indexed on orthorhombic cell. TG curves of Tl 2 U(MoO 4 ) 3 and Tl 4 U(MoO 4 ) 4 did not show any weight change up to 700 deg C in an inert atmosphere. During heating in an inert atmosphere, Tl 2 U(MoO 4 ) 3 and Tl 4 U(MoO 4 ) 4 showed endothermic Dta peaks due to melting of the compounds at 519 and 565 deg C, respectively. (author)

  6. An analysis of annual maximum streamflows in Terengganu, Malaysia using TL-moments approach

    Science.gov (United States)

    Ahmad, Ummi Nadiah; Shabri, Ani; Zakaria, Zahrahtul Amani

    2013-02-01

    TL-moments approach has been used in an analysis to determine the best-fitting distributions to represent the annual series of maximum streamflow data over 12 stations in Terengganu, Malaysia. The TL-moments with different trimming values are used to estimate the parameter of the selected distributions namely: generalized pareto (GPA), generalized logistic, and generalized extreme value distribution. The influence of TL-moments on estimated probability distribution functions are examined by evaluating the relative root mean square error and relative bias of quantile estimates through Monte Carlo simulations. The boxplot is used to show the location of the median and the dispersion of the data, which helps in reaching the decisive conclusions. For most of the cases, the results show that TL-moments with one smallest value was trimmed from the conceptual sample (TL-moments (1,0)), of GPA distribution was the most appropriate in majority of the stations for describing the annual maximum streamflow series in Terengganu, Malaysia.

  7. Emergence of topological and topological crystalline phases in TlBiS2 and TlSbS2

    KAUST Repository

    Zhang, Qingyun

    2015-02-11

    Using first-principles calculations, we investigate the band structure evolution and topological phase transitions in TlBiS2 and TlSbS2 under hydrostatic pressure as well as uniaxial and biaxial strain. The phase transitions are identified by parity analysis and by calculating the surface states. Zero, one, and four Dirac cones are found for the (111) surfaces of both TlBiS2 and TlSbS2 when the pressure grows, which confirms trivial-nontrivial-trivial phase transitions. The Dirac cones at the (M) over bar points are anisotropic with large out-of-plane component. TlBiS2 shows normal, topological, and topological crystalline insulator phases under hydrostatic pressure, thus being the first compound to exhibit a phase transition from a topological to a topological crystalline insulator.

  8. Emergence of topological and topological crystalline phases in TlBiS2 and TlSbS2

    KAUST Repository

    Zhang, Qingyun; Cheng, Yingchun; Schwingenschlö gl, Udo

    2015-01-01

    Using first-principles calculations, we investigate the band structure evolution and topological phase transitions in TlBiS2 and TlSbS2 under hydrostatic pressure as well as uniaxial and biaxial strain. The phase transitions are identified by parity analysis and by calculating the surface states. Zero, one, and four Dirac cones are found for the (111) surfaces of both TlBiS2 and TlSbS2 when the pressure grows, which confirms trivial-nontrivial-trivial phase transitions. The Dirac cones at the (M) over bar points are anisotropic with large out-of-plane component. TlBiS2 shows normal, topological, and topological crystalline insulator phases under hydrostatic pressure, thus being the first compound to exhibit a phase transition from a topological to a topological crystalline insulator.

  9. Gamma spectra analysis from a NaI(Tl) scintillation detector using a micro-computer

    International Nuclear Information System (INIS)

    Levinson, S.

    1990-01-01

    A software package of programs was devloped for qualitative and quantitative evaluation of gamma ray spectra obtained from a NaI(Tl) scintilation counter, by means of a micro-computer. The programs can easily be transformed for use with a Ge(Li) detector. The various algorithms enable automatic analyzing of a spectrum and also interactive or manual mode. The graphic programs display the measured spectrum as well as spectra of standard radionuclides which helps in the determination of peaks and related radionuclides in the spectrum. The peak search is carried out on a smoothed spectrum and is done by checking the behaviour of the second and third derivatives. The algorithm solves the problem of overlapping peaks and performs gaussian fitting, if necessary. Determination of the various radionuclides in the spectrum is done by linear minimum least squares techniques. Overall analysis of the radionuclides activities in the spectrum is obtained for samples of various counting geometries. In addition, a model was developed for efficiency calibration of flat 3X3 inch NaI(Tl) detectors for different samples measured in various counting geometries. It is based on point source experimental efficiency curve fitting. (author)

  10. Tl-201 per rectum scintigraphy in chronic liver disease: assessment of Tl-201 uptake indices

    International Nuclear Information System (INIS)

    Moon, Won Jin; Choi, Yun Young; Cho, Suk Shin; Lee, Min Ho

    1999-01-01

    Heart to liver ratio on Tl-201 per rectal scintigraphy (shunt index) is known to be useful in the assessment of portal systemic shunt. We assessed Tl-201 uptake pattern and early liver/heart uptake rate of Tl-201 and correlated with shunt index in patients with chronic active hepatitis (CAH) and liver cirrhosis (LC). Fifty eight patients with biopsy-proven chronic liver disease (35 with CAH, 23 with LC) underwent Tl-201 per rectum scintigraphy after instillation of 18.5 MBq of Tl-201 into the upper rectum. We evaluated hepatic uptake (type 1: homogeneous, 2: inhomogeneous segmental, 3: inhomogeneous nonsegmental) and extrahepatic uptake of spleen, heart and kidney (grade 0: no uptake, 1: less than liver, 2: equal to liver, 3: greater than liver). We measured the early liver/heart uptake rate (the slope of the liver to heart uptake ratio for 10 mim) and shunt index (heart to liver uptake ratio). Tl-201 uptake pattern and early liver/heart uptake rate of Tl-201 was correlated with the pathologic diagnosis and shunt index. Hepatic uptake patterns of type 1 and 2 were dominant in CAH (CAH: 27/35, LC: 8/23), and type 3 in LC (CAH: 8/35, LC: 15/23)(p<0.005). The grades of extrahepatic uptake were higher in LC than in CAH (spleen: p<0.001, other soft tissue: p<0.005). The early liver/heart uptake rate of CAH (0.110±0.111) was significantly higher than that of LC (0.014±0.090)(p<0.001). The sensitivity and specificity of the early liver/heart uptake rate were 77.7% and 67.7% in differentiating LC from CAH. There was negative correlation between early liver/heart uptake rate and shunt index (r=-0.3347, p<0.01). Hepatic and extrahepatic uptake pattern and early liver/heart uptake rate on Tl-201 per rectum scintigraphy are useful in the assessment of portal systemic shunt in patients with chronic liver disease

  11. Enhancement of thermoelectric efficiency of CoSb3-based skutterudites by double filling with K and Tl

    Directory of Open Access Journals (Sweden)

    Ken eKurosaki

    2014-10-01

    Full Text Available The high-temperature thermoelectric properties of thallium (Tl and potassium (K double-filled cobalt antimonide (CoSb3-based skutterudites with nominal compositions TlxK0.3Co4Sb12 (x = 0.1–0.3 were investigated. The filling fraction of Tl in CoSb3 was enhanced by co-filling with K, which resulted in all of the samples showing the filled-skutterudite single phase. Owing to the high filling ratio, the carrier concentration in the sample with x = 0.3 was as high as 4.3 × 1020 cm−3 at room temperature. Furthermore, quite low lattice thermal conductivity (as low as 0.9 W m−1 K−1 was obtained for the sample with x = 0.3, probably because of strong phonon scattering by the Tl and K co-rattling effect, which resulted in a maximum zT of around one at 773 K.

  12. Insight on a novel layered semiconductors: CuTlS and CuTlSe

    Energy Technology Data Exchange (ETDEWEB)

    Aliev, Ziya S., E-mail: ziyasaliev@gmail.com [Institute of Catalysis and Inorganic Chemistry, ANAS, H.Javid ave. 113, AZ1143 Baku (Azerbaijan); Institute of Physics, ANAS, H.Javid ave. 131, AZ1143 Baku (Azerbaijan); Donostia International Physics Center (DIPC), 20080 San Sebastian (Spain); Zúñiga, Fco. Javier [Departamento de Física de la Materia Condensada, Facultad de Ciencia y Tecnología, Universidad del País Vasco, Apdo. 644, 48080 Bilbao (Spain); Koroteev, Yury M. [Institute of Strength Physics and Materials Science, Russian Academy of Sciences, Siberian Branch, 634055 Tomsk (Russian Federation); Tomsk State University, Tomsk, 634050 (Russian Federation); Breczewski, Tomasz [Departamento de Física de la Materia Condensada, Facultad de Ciencia y Tecnología, Universidad del País Vasco, Apdo. 644, 48080 Bilbao (Spain); Babanly, Nizamaddin B. [Institute of Catalysis and Inorganic Chemistry, ANAS, H.Javid ave. 113, AZ1143 Baku (Azerbaijan); Amiraslanov, Imamaddin R. [Institute of Physics, ANAS, H.Javid ave. 131, AZ1143 Baku (Azerbaijan); Politano, Antonio [Department of Physics, University of Calabria, 87036 Rende (CS) (Italy); Madariaga, Gotzon [Departamento de Física de la Materia Condensada, Facultad de Ciencia y Tecnología, Universidad del País Vasco, Apdo. 644, 48080 Bilbao (Spain); Babanly, Mahammad B. [Institute of Catalysis and Inorganic Chemistry, ANAS, H.Javid ave. 113, AZ1143 Baku (Azerbaijan); and others

    2016-10-15

    Single crystals of the ternary copper compounds CuTlS and CuTlSe have been successfully grown from stoichiometric melt by using vertical Bridgman-Stockbarger method. The crystal structure of the both compounds has been determined by powder and single crystal X-Ray diffraction. They crystallize in the PbFCl structure type with two formula units in the tetragonal system, space group P4/nmm, a=3.922(2); c=8.123(6); Z=2 and a=4.087(6); c=8.195(19) Å; Z=2, respectively. The band structure of the reported compounds has been analyzed by means of full-potential linearized augmented plane-wave (FLAPW) method based on the density functional theory (DFT). Both compounds have similar band structures and are narrow-gap semiconductors with indirect band gap. The resistivity measurements agree with a semiconductor behavior although anomalies are observed at low temperature. - Graphical abstract: The crystal structures of CuTl and CuTlSe are isostructural with the PbFCl-type and the superconductor LiFeAs-type tetragonal structure. The band structure calculations confirmed that they are narrow-gap semiconductors with indirect band gaps of 0.326 and 0.083 eV. The resistivity measurements, although confirming the semiconducting behavior of both compounds exhibit unusual anomalies at low temperatures. - Highlights: • Single crystals of CuTlS and CuTlSe have been successfully grown by Bridgman-Stockbarger method. • The crystal structure of the both compounds has been determined by single crystal XRD. • The band structure of the both compounds has been analyzed based on the density functional theory (DFT). • The resistivity measurements have been carried out from room temperature down to 10 K.

  13. Scintillation response of CsI: Tl crystal under neutron, gamma, alpha particles and beta excitations

    Energy Technology Data Exchange (ETDEWEB)

    Pereira, Maria da Conceicao Costa; Madi Filho, Tufic; Lopes, Valdir Maciel; Berretta, Jose Roberto; Cardenas, Jose Patricio Nahuel, E-mail: macoper@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2015-07-01

    Among the converters of X and gamma radiation in light photons, known as scintillators, the one which is the most efficient emits photons with a wavelength near 400 nm. Particularly, among them, the cesium iodine doped with thallium (CsI:Tl) crystal is that which matches better between the light emission spectrum (peak at 540 nm) and the quantum sensitivity curve of the photodiodes and CCD (Charge Coupled Device). This explains the renewed interest in using this crystal as scintillator. Although the CsI:Tl crystal is commercially available, its local development would give the possibility to obtain it in different geometric configurations and coupling. Moreover, there is a special interest in studying new conditions that will alter the properties of this crystal in order to achieve a optimal level of its functional characteristics. Having an efficient national scintillator with low cost is a strategic opportunity to study the response of a detector applied to different types of radiation. The crystal of cesium iodide activated with thallium (CsI:Tl) has a high gamma detection efficiency per unit volume. In this paper, the CsI:Tl crystal, grown by the vertical Bridgman technique in evacuated silica ampoules and with the purpose of use as radiation detectors, is described. To evaluate the scintillator, measures of the thallium distribution in the crystal volume were taken, with overall efficiency score. The scintillator response was studied through gamma radiation from sources of {sup 137}Cs, {sup 60}Co, {sup 22}Na, {sup 54}Mn, {sup 131}I and {sup 99m}Tc; the beta radiation from source of {sup 90}Sr/{sup 90}Y, alpha particles from {sup 241}Am source and the scintillator response to neutrons from Am/Be source. The energetic resolution for {sup 137}Cs gamma rays (662 keV) was 10%. The results showed the validity of using the CsI:Tl crystal developed in our laboratory, in many applications in the area of radiation detectors. (author)

  14. Magnetic properties of Bi- and Tl- based new high-Tc superconductors

    International Nuclear Information System (INIS)

    Togano, K.; Kumakura, H.; Dietderich, D.H.

    1988-01-01

    Upper critical field H c2 and Magnetization curve were measured for new high-T c oxide superconductors of Bi-Sr-Ca-Cu-O and Tl-Ba-Ca-Cu-O systems. H c2 values at 77K for the high-T phase of Bi-Sr-Ca-Cu-O, low-T c (T c (ρ = 0) = 105K) phase of Tl-Ba-Ca-Cu-O, and high-T c (T c (ρ = 0)=115K) phase of Tl-Ba-Ca-Cu-O are 41T, 50T, and 100T, respectively. The magnetization curve of the Bi-Sr-Ca-Cu-O shows a relatively small hysterisis, suggesting a weak pinning force compared to Tl-Ba-Ca-Cu-O as well as Ba 2 YCU 3 O x . Critical current density J c of 600A/Cm 2 at 77K and zero-magnetiac field was attained for the high-T c sample of Tl-Ba-Ca-Cu-O

  15. Emission properties of thermoluminescence from natural quartz - blue and red TL response to absorbed dose

    International Nuclear Information System (INIS)

    Hashimoto, T.; Yokosaka, K.; Habuki, H.

    1987-01-01

    The TL spectrometry of natural quartz exposed to a gamma radiation dose of 8.8 kGy proved that the red TL, mainly from volcanically originated quartz, has a broad emission band with a peak around 620 nm, while the blue TL from plutonically originated quartz also has a broad emission band giving a peak around 470 nm. These typical red or blue intrinsic colours were also confirmed on the thermoluminescence colour images (TLCI). Exceptionally, a pegmatite quartz changed its TLCI colour from red to blue when the absorbed dose was increased. By using colour filter assemblies, all these quartz samples were shown to emit mainly blue and red TLs, which have distinctly different TL responses to the absorbed dose; the blue invariably showed a supralinearity relation between 1 and 10 kGy dose. For the purpose of dating, the use of red TL, is preferable. The red TL component is related to the impurity Eu content in quartz minerals. (author)

  16. Detection of irradiated foods by the thermoluminescence. Relationships between the temperature ranges of integrating TL glow curves and TL glow ratios

    International Nuclear Information System (INIS)

    Sekiguchi, Masayuki; Yamazaki, Masao; Goto, Michiko; Todoriki, Setsuko; Hagiwara, Shoji

    2007-01-01

    Our study demonstrated that the effects of the several temperature ranges for integrating TL glow intensity on the TL glow ratios by using spice-set purchased at a Turkish air port. The spice set had no labeling of irradiation feeds, but nine of 12 spices were judged as irradiated food in this study. Those temperature ranges were defined by evaluating the glow curves of irradiated TLD-100 chip (167-230degC), TLD-100 disc (177-238degC) and Dolomite element (145-258degC). Those are relatively stable and the difference of typical glow peak temperatures of TLD-100 disc in two institutes was less than 2%. On the other hand, those of TLD-100 tip was shift to higher temperature side at about 4degC because of declining of thermal conductance. The temperature ranges defined by TLD-100 were showed that discriminate more clearly between irradiated and nonirradiated spices compared with the full temperature range of TL measurement (70-400degC). With the exception of low glow intensity, background measurement for estimating net glow intensity was not necessary because TL glow ratio was hardly influenced whether the background measured or not. (author)

  17. Development of NaI(Tl) scintillating films for imaging soft x-rays

    International Nuclear Information System (INIS)

    Shepherd, J.A.

    1993-01-01

    Thin film NaI(Tl) scintillators, of areas of up to 130 cm 2 , have been fabricated and characterized for use on soft x-ray imaging photomultiplier tubes. Relevant parameters of photon-counting imaging detectors are defined and used to predict the performance of several materials, including CsI(Na), CsI(Tl), CaF 2 (Eu), Lu 2 (SiO 4 )O:Ce, and NaI(Tl), as thin film scintillators on fiber optic substrates. Also, x-ray imaging methodologies are compared. The NaI(Tl) films were vapor-deposited onto quartz and fiber optic substrates using a powder flash deposition technique. When compared to single crystal NaI(Tl), the films were found to have equally high light yield but lower energy resolution. Light yield optimization was studied in detail including the effects of substrate temperature, activator concentration in the evaporant, and boat temperature. Spatial resolution as well as parallax errors are discussed and measured for film thicknesses up to 61 μm. A technique is described that can substantially increase the light collection of high index films on fiber optic disks. The light collection was improved by 20% by coating the disk with potassium silicate before the NaI(Tl) deposition. Large area films, up to 130 cm 2 , had a spatial uniformity of response within ±1.5% for count rate and ±3.5% for light yield, and their spatial resolution exceeded 16.6 lp mm -1 when deposited onto fiber optic substrates. The 8-keV x-ray detection efficiency of the microchannel plate imaging photomultiplier tube coupled to a NaI(Tl) film scintillator is predicted to be 88%. Other uses for the films are also described

  18. Stability of Tl-Ba-Ca-Cu-O Superconducting Thin Films

    Energy Technology Data Exchange (ETDEWEB)

    Siegal, M.P.; Overmyer, D.L.; Venturini, E.L.; Padilla, R.R.; Provencio, P.N.

    1999-08-23

    We report the stability of TlBa{sub 2}CaCu{sub 2}O{sub 7} (Tl-1212) and Tl{sub 2}Ba{sub 2}CaCu{sub 2}O{sub 8} (T1-2212) thin films and by inference, the stability of TlBa{sub 2}Ca{sub 2}Cu{sub 3}O{sub 9} (Tl-1223) and Tl{sub 2}Ba{sub 2}Ca{sub 2}Cu{sub 3}O{sub 10} (Tl-2223) thin films, under a variety of conditions. In general, we observe that the stability behavior of the single Tl-O layer materials (Tl-1212 and Tl-1223)are similar and the double Tl-O layer materials (Tl-2212 and Tl-2223) are similar. All films are stable with repeated thermal cycling to cryogenic temperatures. Films are also stable in acetone and methanol. Moisture degrades film quality rapidly, especially in the form of vapor. Tl-1212 is more sensitive to vapor than Tl-2212. These materials are stable to high temperatures in either N{sub 2}, similar to vacuum for the cuprates, and O{sub 2} ambients. While total degradation of properties (superconducting and structural) occur at the same temperatures for all phases, 600 C in N{sub 2} and 700 C in O{sub 2}, the onset of degradation occurs at somewhat lower temperatures for Tl-1212 than for Tl-2212 films. In all cases, sample degradation is associated with Tl depletion from the films.

  19. Tl and OSL dosimetry of diamond films CVD pure and unpurified with boron-carbon; Dosimetria Tl y OSL de peliculas de diamante CVD puras e impurificadas con boro-carbono

    Energy Technology Data Exchange (ETDEWEB)

    Melendrez, R.; Pedroza M, M.; Chernov, V.; Ochoa N, J.D.; Bernal, R.; Barboza F, M. [CIF, UNISON, A.P. 5-088, 83190 Hermosillo, Sonora (Mexico); Castaneda, B. [Departamento de Fisica, Universidad de Sonora, Apdo. Postal 1626, Hermosillo, Sonora (Mexico); Goncalves, J.A.N.; Sandonato, G.M. [Laboratorio Associado de Plasma, Instituto Nacional de Pesquisas Espaciais C.P. 515- 12201 -970, Sao Jose dos Campos, SP (Brazil); Cruz Z, E. [Instituto de Ciencias Nucleares, UNAM, Apdo. Postal 70-543, 04510 Mexico D.F. (Mexico); Preciado F, S.; Cruz V, C.; Brown, F. [Departamento de Investigacion en Polimeros y Materiales de la Universidad de Sonora, Apdo. Postal 130, 83000 Hermosillo, Sonora (Mexico); Schreck, M. [Universitaet Augsburg, Institut fuer Physik D-86135 Augsburg (Germany)

    2004-07-01

    The diamond is a material that possesses extreme physical properties, such as its hardness to the radiation, its low chemical reactivity besides its equivalence to the human tissue, which qualify him as an ideal material for radiation dosimetry. In this work, it was studied the thermal and optically stimulated response (Tl and OSL) of polycrystalline diamond films grown by the technique of CVD pure and contaminated with Boron-carbon (B/C) with the intention of characterizing their efficiency like a dosemeter for radiation in a range of 0 - 3000 Gy. For the case of the films without impurities, the Tl curve presents four main peaks, two of them in an interval of temperatures of 150-200 C and other two additional around of 250-400 C. The dependence of the response of integrated Tl and that of OSL always maintained a lineal relationship with the exhibition dose up to 100 Gy. The behavior of the films contaminated with B/C (2000 - 20000 ppm) was established through experiments that involved the signal of OSL and their relationship with the Tl response. It was found that this processes are correlated, since the electrons caught in the traps of low temperature (50 - 250 C) of the Tl they are the electrons that recombining with more probability to provide the signal of OSL. According to these results it is possible to propose the diamond films as a good candidate for dosimetry to, using the traditional technique of Tl so much as well as the but recent of OSL. (Author)

  20. NaI(Tl) electron energy resolution

    CERN Document Server

    Mengesha, W

    2002-01-01

    NaI(Tl) electron energy resolution eta sub e was measured using the Modified Compton Coincidence Technique (MCCT). The MCCT allowed detection of nearly monoenergetic internal electrons resulting from the scattering of incident 662 keV gamma rays within a primary NaI(Tl) detector. Scattered gamma rays were detected using a secondary HPGe detector in a coincidence mode. Measurements were carried out for electron energies ranging from 16 to 438 keV, by varying the scattering angle. Measured HPGe coincidence spectra were deconvolved to determine the scattered energy spectra from the NaI(Tl) detector. Subsequently, the NaI(Tl) electron energy spectra were determined by subtracting the energy of scattered spectra from the incident source energy (662 keV). Using chi-squared minimization, iterative deconvolution of the internal electron energy spectra from the measured NaI(Tl) spectra was then used to determine eta sub e at the electron energy of interest. eta sub e values determined using this technique represent va...

  1. Effects of ischemic-like insult on myocardial 201Tl accumulation

    International Nuclear Information System (INIS)

    Goldhaber, S.Z.; Newell, J.B.; Alpert, N.M.; Andrews, E.; Pohost, G.M.; Ingwall, J.S.

    1983-01-01

    Despite extensive clinical use of thallium-201 ( 201 Tl) for myocardial imaging, the effect of ischemia on myocardial accumulation and release of 201 Tl independent of flow has not been fully defined. Therefore, myocardial accumulation of 201 Tl in response to ischemic-like myocardial injury was assessed in vitro using the cultured fetal mouse heart preparation. Cultured fetal mouse hearts (n . 311) were subjected to injury simulating ischemia by deprivation of oxygen and oxidizable substrates for periods ranging from 15 minutes to 10 hours. The extent of irreversible injury was determined by the percentage of lactic dehydrogenase (LDH) lost from the hearts to the culture medium during recovery from injury. Injury was essentially reversible at 1 hour of insult. The fraction of 201 Tl content in injured compared with control hearts was not significantly lower after 1 hour of insult. By 3 hours of insult, irreversible injury as assessed by loss of LDH was detectable and the extent of injury increased progressively through 10 hours. During the 3-10-hour period of irreversible injury, 201 Tl accumulation within injured hearts compared with controls was related in a monotonically decreasing fashion to the loss of LDH as described by a mathematical kinetic model that fit the observations closely (R2 greater than 0.99). These results indicate that in this organ culture preparation, in which there is effectively an unlimited reservoir of 201 Tl and no confounding effects of perfusion, the time-dependent 201 Tl accumulation is determined by the extent of irreversible injury

  2. Calibration of a single hexagonal NaI(Tl) detector using a new numerical method based on the efficiency transfer method

    Energy Technology Data Exchange (ETDEWEB)

    Abbas, Mahmoud I., E-mail: mabbas@physicist.net [Physics Department, Faculty of Science, Alexandria University, 21511 Alexandria (Egypt); Badawi, M.S. [Physics Department, Faculty of Science, Alexandria University, 21511 Alexandria (Egypt); Ruskov, I.N. [Frank Laboratory of Neutron Physics, Joint Institute for Nuclear Research, 141980 Dubna (Russian Federation); Institute for Nuclear Research and Nuclear Energy, Bulgarian Academy of Sciences, 1784 Sofia (Bulgaria); El-Khatib, A.M. [Physics Department, Faculty of Science, Alexandria University, 21511 Alexandria (Egypt); Grozdanov, D.N. [Frank Laboratory of Neutron Physics, Joint Institute for Nuclear Research, 141980 Dubna (Russian Federation); Institute for Nuclear Research and Nuclear Energy, Bulgarian Academy of Sciences, 1784 Sofia (Bulgaria); Thabet, A.A. [Department of Medical Equipment Technology, Faculty of Allied Medical Sciences, Pharos University in Alexandria (Egypt); Kopatch, Yu.N. [Frank Laboratory of Neutron Physics, Joint Institute for Nuclear Research, 141980 Dubna (Russian Federation); Gouda, M.M. [Physics Department, Faculty of Science, Alexandria University, 21511 Alexandria (Egypt); Skoy, V.R. [Frank Laboratory of Neutron Physics, Joint Institute for Nuclear Research, 141980 Dubna (Russian Federation)

    2015-01-21

    Gamma-ray detector systems are important instruments in a broad range of science and new setup are continually developing. The most recent step in the evolution of detectors for nuclear spectroscopy is the construction of large arrays of detectors of different forms (for example, conical, pentagonal, hexagonal, etc.) and sizes, where the performance and the efficiency can be increased. In this work, a new direct numerical method (NAM), in an integral form and based on the efficiency transfer (ET) method, is used to calculate the full-energy peak efficiency of a single hexagonal NaI(Tl) detector. The algorithms and the calculations of the effective solid angle ratios for a point (isotropic irradiating) gamma-source situated coaxially at different distances from the detector front-end surface, taking into account the attenuation of the gamma-rays in the detector's material, end-cap and the other materials in-between the gamma-source and the detector, are considered as the core of this (ET) method. The calculated full-energy peak efficiency values by the (NAM) are found to be in a good agreement with the measured experimental data.

  3. [Tl(III)(dota)](-): An Extraordinarily Robust Macrocyclic Complex.

    Science.gov (United States)

    Fodor, Tamás; Bányai, István; Bényei, Attila; Platas-Iglesias, Carlos; Purgel, Mihály; Horváth, Gábor L; Zékány, László; Tircsó, Gyula; Tóth, Imre

    2015-06-01

    The X-ray structure of {C(NH2)3}[Tl(dota)]·H2O shows that the Tl(3+) ion is deeply buried in the macrocyclic cavity of the dota(4-) ligand (1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetate) with average Tl-N and Tl-O distances of 2.464 and 2.365 Å, respectively. The metal ion is directly coordinated to the eight donor atoms of the ligand, which results in a twisted square antiprismatic (TSAP') coordination around Tl(3+). A multinuclear (1)H, (13)C, and (205)Tl NMR study combined with DFT calculations confirmed the TSAP' structure of the complex in aqueous solution, which exists as the Λ(λλλλ)/Δ(δδδδ) enantiomeric pair. (205)Tl NMR spectroscopy allowed the protonation constant associated with the protonation of the complex according to [Tl(dota)](-) + H(+) ⇆ [Tl(Hdota)] to be determined, which turned out to be pK(H)Tl(dota) = 1.4 ± 0.1. [Tl(dota)](-) does not react with Br(-), even when using an excess of the anion, but it forms a weak mixed complex with cyanide, [Tl(dota)](-) + CN(-) ⇆ [Tl(dota)(CN)](2-), with an equilibrium constant of Kmix = 6.0 ± 0.8. The dissociation of the [Tl(dota)](-) complex was determined by UV-vis spectrophotometry under acidic conditions using a large excess of Br(-), and it was found to follow proton-assisted kinetics and to take place very slowly (∼10 days), even in 1 M HClO4, with the estimated half-life of the process being in the 10(9) h range at neutral pH. The solution dynamics of [Tl(dota)](-) were investigated using (13)C NMR spectroscopy and DFT calculations. The (13)C NMR spectra recorded at low temperature (272 K) point to C4 symmetry of the complex in solution, which averages to C4v as the temperature increases. This dynamic behavior was attributed to the Λ(λλλλ) ↔ Δ(δδδδ) enantiomerization process, which involves both the inversion of the macrocyclic unit and the rotation of the pendant arms. According to our calculations, the arm-rotation process limits the Λ(λλλλ) ↔

  4. Ultrashort-period lateral composition modulation in TlInGaAsN/TlInP structures

    International Nuclear Information System (INIS)

    Ishimaru, Manabu; Tanaka, Yuusuke; Hasegawa, Shigehiko; Asahi, Hajime; Sato, Kazuhisa; Konno, Toyohiko J.

    2009-01-01

    We prepared TlInGaAsN/TlInP quantum well structures using gas source molecular-beam epitaxy and characterized them by means of transmission electron microscopy and scanning transmission electron microscopy. It was found that naturally formed vertical quantum wells, so-called lateral composition modulation (LCM), with a periodicity of ∼1 nm are formed in TlInGaAsN layers. We discuss their formation process using a simple kinetic Ising model for layer-by-layer growth, and point out that the formation of ultrashort-period LCM is a universal phenomenon in most of epitaxially grown III-V semiconductor alloys.

  5. Preliminary results on TL and OSL aluminium oxide dosimeters developed at IPEN

    Energy Technology Data Exchange (ETDEWEB)

    Fukumori, David T.; Yoshito, Walter K.; Ussui, Valter; Lazar, Dolores R.R.; Campos, Leticia L., E-mail: fukumori@ipen.b [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2011-07-01

    The aluminum oxide composes the modern TL and OSL radiation dosimeters. TL and OSL phenomena are related to chemical elements in the crystalline structure of {alpha}-Al{sub 2}O{sub 3}. The aim of this work was to develop materials based on aluminum oxide for use in TL and OSL dosimetry. The studies included the dosimetric properties of alumina samples obtained by electro fusion, adsorption and coprecipitation. Electro fused alumina commercially available as abrasive particles was used to produce the pellets by glass sintering. Adsorption and coprecipitation were the methods used to insert metal ions to alumina. The best results were achieved with electro fused alumina and Tm{sup 3+} doped Al{sub 2}O{sub 3} pellets. The electro fused alumina-glass pellets show TL and OSL signals and the TL curve has two peaks. Its minimum detectable radiation dose is 7.2 mGy and the linearity of TL response as function of dose is up to about 800 mGy. The {alpha}-Al{sub 2}O{sub 3}:Tm pellets produced by sintering at 1550 deg C presented a meaningful TL glow curve so that it is worth studying their properties and viability of use in dosimetry. (author)

  6. 201Tl in myocardial diagnosis: studies on the influence of dipyridamole, dobutamine ergometer exercise and background subtraction on the 201Tl myocadial scintiscam

    International Nuclear Information System (INIS)

    Seiderer, M.

    1979-01-01

    Changes in 201 Tl myocardial scintiscans upon administration of dipyridamole or dobutamine and upon ergometer exercise relative to scintiscans at rest were investigated as well as the influence of myocardial background subtraction on scintiscan quality and information. A total of 90 201 Tl examinations were carried out in 59 patients. 18 patients had no myocardial disease, 30 patients had a coronary disease, 5 patients suffered from cardiomyopathy and 6 from left ventricular hypertrophy. The findings are discussed in detail. (orig.) [de

  7. Characterization of cartilaginous tumors with 201Tl scintigraphy

    International Nuclear Information System (INIS)

    Higuchi, Takahiro; Taki, Junichi; Sumiya, Hisashi; Kinuya, Seigo; Nakajima, Kenichi; Tonami, Norihisa

    2005-01-01

    Histological diagnosis and grading of cartilaginous tumors are closely correlated with patient prognosis; consequently, they are essential elements. We attempted to clarify the characteristics of 201 Tl uptake in various histological types of cartilaginous tumors and to assess its clinical value. Twenty-two cases with histologically proven cartilaginous tumors (3 enchondromas, 15 conventional chondrosarcomas (grade I=9, II=5, III=1), 3 mesenchymal chondrosarcomas, and 1 de-differentiated chondrosarcoma) were examined retrospectively. Planar 201 Tl images were recorded 15 mm following intravenous injection of 201 Tl (111 MBq). 201 Tl uptake in the tumor was evaluated visually employing a five-grade scoring system: 0=no appreciable uptake, 1=faint uptake above the background level, 2=moderate uptake, 3=intense uptake but lower than heart uptake and 4=uptake higher than heart uptake. 201 Tl uptake scores were 0 in 3 of 3 enchondromas, 9 of 9 grade I, and 4 of 5 grade II conventional chondrosarcomas. 201 Tl uptake scores were 1 among 1 of 5 grades II and a grade III conventional chondrosarcoma. Mesenchymal chondrosarcoma and de-differentiated chondrosarcoma displayed 201 Tl uptake scores of 2 or 3. Absence of elevated 201 Tl uptake in cartilaginous tumors was indicative of enchondroma or low-grade conventional chondrosarcoma. However, in instances in which 201 Tl uptake is obvious, high-grade chondrosarcoma or variant types should be considered. (author)

  8. Sample dependent correlation between TL and LM-OSL in Al2O3:C

    International Nuclear Information System (INIS)

    Dallas, G.I.; Polymeris, G.S.; Stefanaki, E.C.; Afouxenidis, D.; Tsirliganis, N.C.; Kitis, G.

    2008-01-01

    Al 2 O 3 :C single crystals are known to exhibit different, sample dependent, glow-curve shapes. The relation between the Thermoluminescence (TL) traps and the linear modulated optically stimulation luminescence (LM-OSL) traps is of high importance. In the present work a correlation study is attempted using 23 single crystals with dimensions between 400 and 500μm. The correlation study involved two steps. In the first step, both TL glow curves and LM-OSL decay curves are deconvoluted and a one-to-one correlation between TL peaks and LM-OSL components is attempted. In the second step the TL glow-curves are corrected for thermal quenching, the corrected curves are deconvoluted and a new correlation between TL and LM-OSL individual components is performed

  9. Centers responsible for the TL peaks of willemite mineral estimated by EPR analysis

    Energy Technology Data Exchange (ETDEWEB)

    Gundu Rao, T.K. [Instituto de Física, Universidade de São Paulo, Rua do Matão, Travessa R, 187, CEP 05508-090, São Paulo, SP (Brazil); Cano, Nilo F., E-mail: nilo.cano@unifesp.br [Departamento de Ciências do Mar, Universidade Federal de São Paulo, Rua Doutor Carvalho de Mendonça, 144, CEP 11070-102, Santos, SP (Brazil); Silva-Carrera, Betzabel N.; Ferreira, Reinaldo M. [Instituto de Física, Universidade de São Paulo, Rua do Matão, Travessa R, 187, CEP 05508-090, São Paulo, SP (Brazil); Javier-Ccallata, Henry S., E-mail: henrysjc@gmail.com [Escuela Profesional de Física, Facultad de Ciencias Naturales y Formales, Universidad Nacional de San Agustín (UNSA), Av. Independencia S/N, Arequipa (Peru); Watanabe, Shigueo, E-mail: watanabe@if.usp.br [Instituto de Física, Universidade de São Paulo, Rua do Matão, Travessa R, 187, CEP 05508-090, São Paulo, SP (Brazil)

    2016-09-15

    The mineral willemite (Zn{sub 2}SiO{sub 4}) exhibits five thermoluminescence (TL) peaks approximately at 160, 225, 260, 310 and 400 °C. Electron paramagnetic resonance (EPR) studies were carried out to study the defect centers induced in the mineral by gamma irradiation and also to identify the centers responsible for the TL process. Room temperature EPR spectrum of irradiated mineral is a superposition of at least four distinct centers. One of the centers (center I) with an isotropic g factor 2.0114 is attributable to an intrinsic O{sup −} type center and the center correlates with the TL peak at 160 °C. Center II exhibiting hyperfine lines is also tentatively assigned to an O{sup −} ion and is related to the low temperature TL peak at 160 °C. Center III is characterized by an axially symmetric g-tensor with principal values g{sub ||}=2.0451 and g{sub ⊥}=2.011 and is identified as an O{sub 2}{sup −} ion. This center appears to be related to 160, 225 and 260 °C TL peaks. Center IV with principal g-values g{sub ||}=2.0025 and g{sub ⊥}=2.0088 is attributed to an F{sup +}-type center (singly ionized oxygen vacancy) and is the likely recombination center for TL peaks between 160 and 310 °C.

  10. Principles of Good Practice in SoTL

    Science.gov (United States)

    Felten, Peter

    2013-01-01

    For the Scholarship of Teaching and Learning (SoTL) to be understood as significant intellectual work in the academy, SoTL practitioners need to identify shared principles of good practice. While honoring the diversity of SoTL in its many forms across the globe, such principles can serve as a heuristic for assessing work in our field. These…

  11. New colour centres in KCl:(Tl+ + Ca2+) and KCl:(Tl+ + Sr2+) crystals

    International Nuclear Information System (INIS)

    Ioan, A.; Topa, V.; Giurgea, M.

    1978-01-01

    Electrolytic colouring under unusual conditions (low temperature and high voltage) gives rise to the appearance of three new absorption bands peaking at 3.2, 2.5, and 1.7 eV and at 2.8, 2.1, and 1.5 eV in KCl:(Tl + + Ca 2+ ) and in KCl:(Tl + + Sr 2+ ) single crystals, respectively. The modifications of the absorption spectra of the coloured crystals induced by the application of a reversed electric field at the colouring temperature or by heat treatment are investigated. It is likely that the colour centre responsible for the new absorption bands is an aggregate centre which, besides an Tl - -complex, contains also at least an Ca(Sr) ion, a trapped electron, and an anionic vacancy. (author)

  12. Deformation effects in electronic spectra of the layered semiconductors TlGaS sub 2 , TlGaSe sub 2 and TlInS sub 2

    CERN Document Server

    Allakhverdiev, K R; Suleymanov, R A; Gasanov, N Z

    2003-01-01

    The deformation effects in electronic spectra of the ternary layered semiconductors TlGaS sub 2 , TlGaSe sub 2 and TlInS sub 2 are considered. It is shown that the influence of hydrostatic pressure, thermal expansion and variation of composition in solid solutions on the band gap of the crystals investigated can be described in the framework of one common model of deformation potentials. This model appears to be close to that of layered semiconductors of the A sub 3 B sub 6 group, attesting to the fact that the main principles of formation of band structure in these two groups of layered crystals are the same.

  13. Alpha particle and proton relative thermoluminescence efficiencies in LiF:Mg, Cu, P:is track structure theory up to the task?

    International Nuclear Information System (INIS)

    Horowitz, Y. S.; Siboni, D.; Oster, L.; Livingstone, J.; Guatelli, S.; Rosenfeld, A.; Emfietzoglou, D.; Bilski, P.; Obryk, B.

    2008-01-01

    Low-energy alpha particle and proton heavy charged particle (HCP) relative thermoluminescence (TL) efficiencies are calculated for the major dosimetric glow peak in LiF:Mg, Cu, P (MCP-N) in the framework of track structure theory (TST). The calculations employ previously published TRIPOS-E Monte Carlo track segment values of the radial dose in condensed phase LiF calculated at the Instituto National de Investigaciones Nucleares (Mexico) and experimentally measured normalised 60 Co gamma-induced TL dose-response functions, f(D), carried out at the Inst. of Nuclear Physics (Poland). The motivation for the calculations is to test the validity of TST in a TL system in which f(D) is not supra-linear (f(D) >1) and is not significantly dependent on photon energy contrary to the behaviour of the dose-response of composite peak 5 in the glow curve of LiF:Mg, Ti (TLD-100). The calculated HCP relative efficiencies in LiF:MCP-N are 23-87 % lower than the experimentally measured values, indicating a weakness in the major premise of TST which exclusively relates HCP effects to the radiation action of the secondary electrons liberated by the HCP slowing down. However, an analysis of the uncertainties involved in the TST calculations and experiments (i.e. experimental measurement of f(D) at high levels of dose, sample light self-absorption and accuracy in the estimation of D R, especially towards the end of the HCP track) indicate that these may be too large to enable a definite conclusion. More accurate estimation of sample light self-absorption, improved measurements of f(D) and full-track Monte Carlo calculations of D R incorporating improvements of the low-energy electron transport are indicated in order to reduce uncertainties and enable a final conclusion. (authors)

  14. Alpha particle and proton relative thermoluminescence efficiencies in LiF:Mg,Cu,P:is track structure theory up to the task?

    Science.gov (United States)

    Horowitz, Y S; Siboni, D; Oster, L; Livingstone, J; Guatelli, S; Rosenfeld, A; Emfietzoglou, D; Bilski, P; Obryk, B

    2012-07-01

    Low-energy alpha particle and proton heavy charged particle (HCP) relative thermoluminescence (TL) efficiencies are calculated for the major dosimetric glow peak in LiF:Mg,Cu,P (MCP-N) in the framework of track structure theory (TST). The calculations employ previously published TRIPOS-E Monte Carlo track segment values of the radial dose in condensed phase LiF calculated at the Instituto National de Investigaciones Nucleares (Mexico) and experimentally measured normalised (60)Co gamma-induced TL dose-response functions, f(D), carried out at the Institute of Nuclear Physics (Poland). The motivation for the calculations is to test the validity of TST in a TL system in which f(D) is not supralinear (f(D) >1) and is not significantly dependent on photon energy contrary to the behaviour of the dose-response of composite peak 5 in the glow curve of LiF:Mg,Ti (TLD-100). The calculated HCP relative efficiencies in LiF:MCP-N are 23-87% lower than the experimentally measured values, indicating a weakness in the major premise of TST which exclusively relates HCP effects to the radiation action of the secondary electrons liberated by the HCP slowing down. However, an analysis of the uncertainties involved in the TST calculations and experiments (i.e. experimental measurement of f(D) at high levels of dose, sample light self-absorption and accuracy in the estimation of D(r), especially towards the end of the HCP track) indicate that these may be too large to enable a definite conclusion. More accurate estimation of sample light self-absorption, improved measurements of f(D) and full-track Monte Carlo calculations of D(r) incorporating improvements of the low-energy electron transport are indicated in order to reduce uncertainties and enable a final conclusion.

  15. Defects that control the properties of Tl- and Hg-based superconductors

    International Nuclear Information System (INIS)

    Jorgensen, J.D.; Chmaissem, O.; Hinks, D.G.; Mitchell, J.F.; Wagner, J.L.; Univ. of North Dakota, Grand Forks, ND; Jensen, W.R.; Dabrowski, B.; Northern Illinois Univ., DeKalb, IL

    1997-03-01

    Defects that affect T c in Tl 2 Ba 2 CuO 6+δ and HgBa 2 CuO 4+δ and HgBa 2 CuO 4+δ have been characterized by neutron powder diffraction. In Tl 2 Ba 2 CuO 6+δ , the dominant defect is interstitial oxygen between the two Tl-O planes, but Cu substitution on the Tl site also affects properties and there is evidence for a second oxygen defect for compositions in the vicinity of maximum T c . In HgBa 2 CuO 4+δ , there are two competing oxygen defects in the Hg layer. The relative concentrations of these defects switches upon passing from the underdoped region, through the maximum T c , to the overdoped region. This remarkable behavior could result from a change in the topology of the Fermi surface upon passing through the van Hove singularity

  16. M1 transitions between superdeformed states in 195Tl

    International Nuclear Information System (INIS)

    Zheng Xing; Xingqu Chen; Xiaochun Wang

    1996-01-01

    Using a triaxial-particle-rotor model, the quadrupole and dipole transition energies, kinematic and dynamic moments of inertia, electromagnetic transition probabilities and the relative intensity of the E2 γ-transitions are calculated for superdeformed bands in 195 Tl. A strong perturbation effect of rotation on transition energies and M1 and E2 transitions of superdeformed states is investigated. The total M1 transitions, enhanced by internal conversion, are expected to compete strongly with the E2 γ-ray at low spins in the superdeformed 195 Tl nucleus. (author)

  17. Preparation of 199Tl using the electroplating gold targets on the internal target installation of cyclotron

    International Nuclear Information System (INIS)

    Zhou Dehai; Xie Degao; Chao Yangshu; Liao Fuquan; Zhang Youfa; Wang Zefu

    1992-01-01

    The separative conditions of 199 Tl from Cu, Au and Ga by reaction 197 Au(α, 2n) 199 Tl on the internal target installation of cyclotron is studied. The α-particle energy is selected in the range of 24-15 MeV. The cumulative current intensities of such α-particle beams bombarding the gold target at 150-200 μA are 1200 μA · h and 1500 μA · h respectively. The radiochemical separation of 199 Tl is carried out with isopropyl ether extraction and anions exchange from the irradiated gold targets. The radioactivities of 199 Tl and 200 Tl are 2.3 x 10 5 Bq and 7.1 x 10 2 Bq, and 200 Tl makes up 0.29% of the total radioactivity. The impurity elements contained 1 ml of 199 TlCl injection solution are Au 199 TlCl has been used in clinical experiments in vivo and relatively good results have been obtained

  18. $\\alpha$-decay study of $^{182,184}$Tl

    CERN Document Server

    Van Beveren, C; Barzakh, A E; Cocolios, T E; de Groote, R P; Fedorov, D; Fedosseev, V N; Ferrer, R; Ghys, L; Huyse, M; Köster, U; Lane, J; Liberati, V; Lynch, K M; Marsh, B A; Molkanov, P L; Procter, T J; Rapisarda, E; Sandhu, K; Seliverstov, M D; Van Duppen, P; Venhart, M; Veselský, M

    2016-01-01

    α -decay spectroscopy of 182,184 Tl has been performed at the CERN isotope separator on-line ( ISOLDE ) facility. New fi ne-structure α decays have been observed for both isotopes. α -decay branching ratios of 0.089 ( 19 ) %, 0.047 ( 6 ) % and 1.22 ( 30 ) % have been deduced for the ( 10 − ) , ( 7 + ) and ( 2 − ) states respectively in 184 Tl and a lower limit of 0.49% for the α -decay branching ratio of 182 Tl. A new half-life of 9.5 ( 2 ) s for the ( 2 − ) state in 184 Tl and 1.9 ( 1 ) s for the low-spin state in 182 Tl has been deduced. Using α – γ coincidence analysis, multiple γ rays were observed de-exciting levels in 178,18 0 Au fed by 182,184 Tl α decays. The γ transitions connecting these low-lying states in 178,18 0 Au are essential to sort the data and possibly identify bands from in- beam studies in these isotopes. Owing to the complex fi ne-structure α decays and limited knowledge about the structure of the daughter nuclei, only partial level schemes could be constructed for bot...

  19. Phytotoxicity of thallium (Tl) in culture solution. Pt. 2. Effects of Tl(III) on the growth and heavy metal contents of pea and field bean plants

    Energy Technology Data Exchange (ETDEWEB)

    Pieper, B; Austenfeld, F A

    1985-01-01

    The effects of Tl(NO/sub 3/)/sub 3/ and Tl(III)EDTA on growth and heavy metal contents of pea plants and field bean plants were compared in hydroponic culture experiments. In the presence of Tl(NO/sub 3/)/sub 3/, the essential heavy metals were available to the plants in their ionic forms. When Tl(III)EDTA was present the essential heavy metals were available as chelated complexes. Dry matter production of the pea plants was inhibited to a greater extent by Tl(III)EDTA than by Tl(NO/sub 3/)/sub 3/. The distribution of Tl within the plant was unaffected by the accompanying anion, however an increase of the Tl content of the stems and the leaves was observed in the presence of Tl(III)EDTA. The micronutrients exhibited different interactions with Tl(III). In the presence of increasing concentrations of Tl(NO/sub 3/)/sub 3/ the Mn content of each organ and the Zn content of the roots were lowered, but the Zn content of the stems was increased. Increasing concentrations of Tl(III)EDTA resulted only in a decrease of the Mn content of the roots, but in an increase of the contents of Fe and Mn within the stems, and Fe, Mn, Zn, and Cu within the leaves. The increases may be due to concentration by growth inhibition. In contrast to pea plants, growth of field bean plants was inhibited only by Tl(NO/sub 3/)/sub 3/. The field bean plants retained most of the Tl within the roots independent of the Tl compound in the solution. Chelation of Tl(III) resulted in higher Tl contents of both the roots and the stems, but equal or reduced Tl contents of the leaves. Whereas increasing concentrations of Tl(NO/sub 3/)/sub 3/ reduced the Mn content of each organ as well as the Zn content of the roots and the leaves, Tl(III)EDTA only reduced the Mn content of the roots.

  20. Real-time in-situ monitoring of the topotactic transformation of TlCu{sub 3}Se{sub 2} into TlCu{sub 2}Se{sub 2}

    Energy Technology Data Exchange (ETDEWEB)

    Ångström, J.; Sahlberg, M.; Berger, R.

    2015-07-15

    Highlights: • Topotactic transition from TlCu{sub 3}Se{sub 2} to TlCu{sub 2}Se{sub 2} followed in situ. • Synchrotron radiation X-ray powder diffraction enabled short scans. • Relative abundance of phases refined from powder data. • Opens up for studying similar systems in the same manner. - Abstract: The solid state transformation of monoclinic TlCu{sub 3}Se{sub 2} into tetragonal TlCu{sub 2}Se{sub 2} by oxidative copper leaching in concentrated ammonia solution has been studied in situ by the use of synchrotron radiation. The diffraction patterns of parent and daughter phase are both sharp, indicating a strong topotactic relationship between them that effectuates a rapid change by “chimie douce” performed at +19 °C. The transformation rate is strongly connected to the access of oxygen from the surrounding air. The transformation was followed in a real-time mode, being almost complete after 2.5 h with 1 h incubation due to low oxygen content, as shown from refining the diffraction patterns by Rietveld profile technique.

  1. Importance of controlling the Tl-oxide partial pressure throughout the processing of TlBa2CaCu2O7 thin films

    International Nuclear Information System (INIS)

    Siegal, M.P.; Venturini, E.L.; Newcomer, P.P.; Overmyer, D.L.; Dominguez, F.; Dunn, R.

    1995-01-01

    TlBa 2 CaCu 2 O 7 (Tl-1212) superconducting films 5000--6000 A thick have been grown on LaAlO 3 (100) substrates using oxide precursors in a closed two-zone thallination furnace. Tl-1212 films can be grown with transition temperatures ∼100 K, and critical current densities measured by magnetization of J cm (5 K)>10 7 A/cm 2 and J cm (77 K)>10 5 A/cm 2 . Processing conditions, substrate temperatures and Tl-oxide source temperatures are found which result in smooth, nearly phase-pure Tl-1212 films. Variations in the respective temperature ramps of the Tl-oxide zone and the substrate zone can greatly influence resulting film properties such as microstructure, morphology, superconducting transition temperature, and critical current density. copyright 1995 American Institute of Physics

  2. A theoretical study of CsI:Tl columnar scintillator image quality parameters by analytical modeling

    Energy Technology Data Exchange (ETDEWEB)

    Kalyvas, N., E-mail: nkalyvas@teiath.gr; Valais, I.; Michail, C.; Fountos, G.; Kandarakis, I.; Cavouras, D.

    2015-04-11

    Medical X-ray digital imaging systems such as mammography, radiography and computed tomography (CT), are composed from efficient radiation detectors, which can transform the X-rays to electron signal. Scintillators are materials that emit light when excited by X-rays and incorporated in X-ray medical imaging detectors. Columnar scintillator, like CsI:T1 is very often used for X-ray detection due to its higher performance. The columnar form limits the lateral spread of the optical photons to the scintillator output, thus it demonstrates superior spatial resolution compared to granular scintillators. The aim of this work is to provide an analytical model for calculating the MTF, the DQE and the emission efficiency of a columnar scintillator. The model parameters were validated against published Monte Carlo data. The model was able to predict the overall performance of CsI:Tl scintillators and suggested an optimum thickness of 300 μm for radiography applications. - Highlights: • An analytical model for calculating MTF, DQE and Detector Optical Gain (DOG) of columnar phosphors was developed. • The model was fitted to published efficiency and MTF Monte Carlo data. • A good fit was observed for 300 µm columnar CsI:Tl thickness. • The performance of the 300 µm column thickness CsI:Tl was better in terms of MTF and DOG for radiographic applications.

  3. Tl and OSL dosimetry of diamond films CVD pure and unpurified with boron-carbon

    International Nuclear Information System (INIS)

    Melendrez, R.; Pedroza M, M.; Chernov, V.; Ochoa N, J.D.; Bernal, R.; Barboza F, M.; Castaneda, B.; Goncalves, J.A.N.; Sandonato, G.M.; Cruz Z, E.; Preciado F, S.; Cruz V, C.; Brown, F.; Schreck, M.

    2004-01-01

    The diamond is a material that possesses extreme physical properties, such as its hardness to the radiation, its low chemical reactivity besides its equivalence to the human tissue, which qualify him as an ideal material for radiation dosimetry. In this work, it was studied the thermal and optically stimulated response (Tl and OSL) of polycrystalline diamond films grown by the technique of CVD pure and contaminated with Boron-carbon (B/C) with the intention of characterizing their efficiency like a dosemeter for radiation in a range of 0 - 3000 Gy. For the case of the films without impurities, the Tl curve presents four main peaks, two of them in an interval of temperatures of 150-200 C and other two additional around of 250-400 C. The dependence of the response of integrated Tl and that of OSL always maintained a lineal relationship with the exhibition dose up to 100 Gy. The behavior of the films contaminated with B/C (2000 - 20000 ppm) was established through experiments that involved the signal of OSL and their relationship with the Tl response. It was found that this processes are correlated, since the electrons caught in the traps of low temperature (50 - 250 C) of the Tl they are the electrons that recombining with more probability to provide the signal of OSL. According to these results it is possible to propose the diamond films as a good candidate for dosimetry to, using the traditional technique of Tl so much as well as the but recent of OSL. (Author)

  4. Correlation between TL and OSL properties of CaF2:N

    International Nuclear Information System (INIS)

    Polymeris, George S.; Kitis, George; Tsirliganis, Nestor C.

    2006-01-01

    Natural CaF 2 is very well known thermoluminescent (TL) material, since it has been extensively used as a dosimeter. Its basic advantage is the exhibited high TL sensitivity. In the present work, the optically stimulated luminescence (OSL) sensitivity of this material was studied by exposing it to environmental radiation for time intervals of few hours up to a few days, and was found to be very high. By analyzing the TL glow curves and the OSL decay curves into their individual glow-peaks and components respectively, a relation between specific glow-peaks and OSL components was established. An intense thermal transfer effect occurring during optical stimulation at high temperature was observed and an explanation is offered according to existing models

  5. Response function study of a scintillator detector of NaI(Tl); Estudo da funcao resposta de um detector cintilador de NaI(Tl)

    Energy Technology Data Exchange (ETDEWEB)

    Villa, Marcelo Barros; Costa, Alessandro Martins da, E-mail: amcosta@usp.br [Universidade de Sao Paulo (FFCLRP/USP), Ribeirao Preto, SP (Brazil). Faculdade de Filosofia, Ciencias e Letras. Dept. de Fisica

    2014-07-01

    In measurements of gamma rays with Nai (Tl) scintillator, the detectors output data are pulse height spectra, that corresponding to distorted information about the radiation source due to various errors associated with the crystal scintillation process and electronics associated, instead of power spectra photons. Pulse height spectra are related to the real power spectra by means of scintillator detector response function NaI (Tl). In this work, the response function for a cylindrical crystal of Nal (Tl) of 7,62 x 7,62 cm (diameter x length) was studied, by Monte Carlo method, using the EGSnrc tool to model the transport of radiation, combined with experimental measurements. An inverse response matrix, even with the energy of the square root, which transforms the pulse height spectrum of photon energy spectrum was obtained. The results of this transformation of pulse height spectrum for photon energy spectrum is presented, showing that the methodology employed in this study is suitable.

  6. Preparation of 199Tl and its labelled compound

    International Nuclear Information System (INIS)

    Zhou Dehai; Guan Changtian; Kuang Anren

    1991-10-01

    Usually, 199 Ti is obtained by the nuclear reaction of 197 Au(α, 2n) 199 Tl. A gold target with 50±0.1 mm in diameter, 0.8 mm in thickness and 99.99% in purity was mounted in a cyclotron beam line. The target was bombarded by α particles with the energy of 25∼27 MeV and the beam current of 15∼20μA. The irradiated gold target was dissolved by aqua regia. Then the saturated aqueous solution of SO 2 was added. The 199 Tl(III)reduced to 199 Tl(I). The deposit of gold was removed. For separation of 199 Tl)I), about 5 mL of raw material solution obtained was transferred to 201 x 8 type anion exchange resin column which had been equilibrated with 4 mol/L HCl. The 199 Tl(I) and Au(III) were desorbed separately with the eluants (90% of aqueous diamide solution,, and 2 mol/L HCL∼5% thiourea) at the flow rate of 0.25 mL/min. After separation, the 10 mL concentrated nitric acid was added to the 199 Tl collected solution to destroy and remove the aqueous diamide solution, then 4 mol/L HCl was added and heated up to remove NO 3 - . The TlCl injection with pH = 5 was made up by using physiological saline. After filtering the 199 TlCl injection was sterilized at 137.3 kPa, 120 deg C about 30 min in an autoclave. The 199 TlCl injection was used in the animal pyrogen, a bacterial, safety, dispensation and myocardial imaging experiments. The good results have been obtained. Now it has undergone clinical experiments

  7. Two crystal structures of Ag sup + -and Tl sup + -exchanged zeolite X, Ag sub 2 sub 7 Tl sub 6 sub 5 -X and Ag sub 2 sub 3 Tl sub 6 sub 9 -X

    CERN Document Server

    Kim, S Y; Kim, Y

    2002-01-01

    Two crystal structures of dehydrated Ag sup + -and Tl sup + -exchanged zeolite X (Ag sub 2 sub 7 Tl sub 6 sub 5 -X and Ag sub 2 sub 3 Tl sub 6 sub 9 -X) have been determined by single-crystal X-ray diffraction techniques in the cubic space group Fd3 at 21(1) .deg. C (a = 24.758(4) A, a = 24.947(4) A, respectively). Their structures were refined to the final error indices R sub 1 = 0.055 and wR sub 2 = 0.057 with 375 reflections, and R sub 1 = 0.058 and wR sub 2 = 0.057 with 235 reflections, respectively, for which I> 3 sigma(I). In the structure of Ag sub 2 sub 7 Tl sub 6 sub 5 -X, 27 Ag sup + ions were found at two crystallographic sites: 15 Ag sup + ions at site I at the center of the hexagonal prism and the remaining 12 Ag sup + ions at site II' in the sodalite cavity. Sixty-five Tl sup + ions were located at three crystallographic sites: 20 Tl sup + ions at site II opposite single six-rings in the supercage, 18 Tl sup + ions at site I' in the sodalite cavity opposite the D6Rs, and the remaining 27 Tl sup ...

  8. Determination of absolute detection efficiencies for detectors of interest in homeland security

    International Nuclear Information System (INIS)

    Ayaz-Maierhafer, Birsen; DeVol, Timothy A.

    2007-01-01

    The absolute total and absolute peak detection efficiencies of gamma ray detector materials NaI:Tl, CdZnTe, HPGe, HPXe, LaBr 3 :Ce and LaCl 3 :Ce were simulated and compared to that of polyvinyltoluene (PVT). The dimensions of the PVT detector were 188.82 cmx60.96 cmx5.08 cm, which is a typical size for a single-panel portal monitor. The absolute total and peak detection efficiencies for these detector materials for the point, line and spherical source geometries of 60 Co (1332 keV), 137 Cs (662 keV) and 241 Am (59.5 keV) were simulated at various source-to-detector distances using the Monte Carlo N-Particle software (MCNP5-V1.30). The comparison of the absolute total detection efficiencies for a point, line and spherical source geometry of 60 Co and 137 Cs at different source-to-detector distance showed that the absolute detection efficiency for PVT is higher relative to the other detectors of typical dimensions for that material. However, the absolute peak detection efficiency of some of these detectors are higher relative to PVT, for example the absolute peak detection efficiency of NaI:Tl (7.62 cm diameterx7.62 cm long), HPGe (7.62 cm diameterx7.62 cm long), HPXe (11.43 cm diameterx60.96 cm long), and LaCl 3 :Ce (5.08 cm diameterx5.08 cm long) are all greater than that of a 188.82 cmx60.96 cmx5.08 cm PVT detector for 60 Co and 137 Cs for all geometries studied. The absolute total and absolute peak detection efficiencies of a right circular cylinder of NaI:Tl with various diameters and thicknesses were determined for a point source. The effect of changing the solid angle on the NaI:Tl detectors showed that with increasing solid angle and detector thickness, the absolute efficiency increases. This work establishes a common basis for differentiating detector materials for passive portal monitoring of gamma ray radiation

  9. Syntheses, crystal structures, and characterization of two new Tl{sup +}-Cu{sup 2+}-Te{sup 6+} oxides: Tl{sub 4}CuTeO{sub 6} and Tl{sub 6}CuTe{sub 2}O{sub 10}

    Energy Technology Data Exchange (ETDEWEB)

    Yeon, Jeongho; Kim, Sang-Hwan [Department of Chemistry, University of Houston, 136 Fleming Building, Houston, TX 77204-5003 (United States); Green, Mark A. [Department of Materials Science and Engineering, University of Maryland, College Park, MD, 20742-2115 and NIST Center for Neutron Research, National Institute of Standard and Technology, 100 Bureau Drive, Gaithersburg, MD 20899-6103 (United States); Bhatti, Kanwal Preet; Leighton, C. [Department of Chemical Engineering and Materials Science, University of Minnesota, Minneapolis, MN 55455-0132 (United States); Shiv Halasyamani, P., E-mail: psh@uh.edu [Department of Chemistry, University of Houston, 136 Fleming Building, Houston, TX 77204-5003 (United States)

    2012-12-15

    Crystals and polycrystalline powders of two new oxide materials, Tl{sub 4}CuTeO{sub 6} and Tl{sub 6}CuTe{sub 2}O{sub 10}, have been synthesized by hydrothermal and solid-state methods. The materials were structurally characterized by single-crystal X-ray diffraction. Tl{sub 4}CuTeO{sub 6} and Tl{sub 6}CuTe{sub 2}O{sub 10} exhibit one dimensional anionic slabs of [CuTeO{sub 6}]{sup 4-} and [CuTe{sub 2}O{sub 10}]{sup 6-}, respectively. Common to both slabs is the occurrence of Cu{sup 2+}O{sub 4} distorted squares and Te{sup 6+}O{sub 6} octahedra. The slabs are separated by Tl{sup +} cations. For Tl{sub 4}CuTeO{sub 6}, magnetic measurements indicate a maximum at {approx}8 K in the temperature dependence of the susceptibility. Low temperature neutron diffraction data confirm no long-range magnetic ordering occurs and the susceptibility was adequately accounted for by fits to a Heisenberg alternating chain model. For Tl{sub 6}CuTe{sub 2}O{sub 10} on the other hand, magnetic measurements revealed paramagnetism with no evidence of long-range magnetic ordering. Infrared, UV-vis spectra, thermogravimetric, and differential thermal analyses are also reported. Crystal data: Tl{sub 4}CuTeO{sub 6}, Triclinic, space group P-1 (No. 2), a=5.8629(8) A, b=8.7848(11) A, c=9.2572(12) A, {alpha}=66.0460(10), {beta}=74.2010(10), {gamma}=79.254(2), V=417.70(9) A{sup 3}, and Z=2; Tl{sub 6}CuTe{sub 2}O{sub 10}, orthorhombic, space group Pnma (No. 62), a=10.8628(6) A, b=11.4962(7) A, c=10.7238(6) A, V=1339.20(13) A{sup 3}, and Z=4. - Graphical Abstract: Two new oxide materials, Tl{sub 4}CuTeO{sub 6} and Tl{sub 6}CuTe{sub 2}O{sub 10}, have been synthesized and characterized. The materials exhibit one dimensional crystal structures consisting of CuO{sub 4} and TeO{sub 6} polyhedra. Highlights: Black-Right-Pointing-Pointer Two New Tl-Te-Cu-oxides have been synthesized and structurally characterized. Black-Right-Pointing-Pointer For Tl{sub 4}CuTeO{sub 6}, magnetic measurements indicate a

  10. Degradation of myocardial perfusion SPECT images caused by contaminants in thallous (201Tl) chloride

    International Nuclear Information System (INIS)

    Staelens, Steven G.; Wit, Tim C. de; Lemahieu, Ignace A.; Beekman, Freek J.

    2008-01-01

    Thallous ( 201 Tl) chloride is a single-photon emission computed tomography (SPECT) tracer mainly used for assessing perfusion and viability of myocardial tissue. 201 Tl emits X-rays around 72 keV and gammas at 167 keV, and has a half-life of 73 h. Regulations allow an intrinsic contamination up to 3-5%, which is mainly caused by 200 Tl (368 keV; 26 h) and by 202 Tl (439 keV; 12.2 days). Contra-intuitive to the low-level percentages in which these contaminants are present, their impact may be significant because of much higher gamma camera sensitivity for these high-energy photon emissions. Therefore, we investigate the effects of the contaminants in terms of detected fractions of photons in projections and contrast degradation in reconstructed images. Acquisitions of a digital thorax phantom filled with thallous ( 201 Tl) chloride were simulated with a validated Monte Carlo tool, thereby, modelling 1% of contamination by 200 Tl and 202 Tl each. In addition, measurements of a thorax phantom on a dual-headed gamma camera were performed. The product used was contaminated by 0.17% of 200 Tl and 0.24% of 202 Tl at activity reference time (ART). This ART is specified by the manufacturer, thereby, accounting for the difference in half-lives of 201 Tl and its contaminants. These measurements were repeated at different dates associated with various contamination levels. Simulations showed that, with 1% of 200 Tl and 202 Tl, the total contamination in the 72 keV window can rise up to one out of three detected photons. For the 167keV window, the contamination is even more pronounced: more than four out of five detections in this photopeak window originate from contaminants. Measurements indicate that cold lesion contrast in myocardial perfusion SPECT imaging is at maximum close to ART. In addition to a higher noise level, relative contrast decreases 15% 2 days early to ART, which is explained by an increase in 200 Tl contamination. After ART, contrast decreased by 16% when

  11. Speciation of Tl(III and Tl(I in hair samples by dispersive liquid–liquid microextraction based on solidification of floating organic droplet prior to flame atomic absorption spectrometry determination

    Directory of Open Access Journals (Sweden)

    S.Z. Mohammadi

    2016-11-01

    Full Text Available Dispersive liquid–liquid microextraction based on solidification of floating organic droplet was successfully used as a sample preparation method prior to flame atomic absorption determination of trace amounts of Tl(III and Tl(I in hair samples. In the proposed method, 1-(2-pyridylazo-2-naphthol, 1-dodecanol and ethanol were used as chelating agent, extraction and dispersive solvent, respectively. Several factors that may be affected in the extraction process, such as type and volume of extraction and disperser solvents, pH, salting out effect, ionic strength and extraction time were studied. Under the optimal conditions, linearity was maintained between 6.0 and 900.0 ng mL−1 for Tl(III. The relative standard deviation for seven replicate determinations of 0.2 μg mL−1 Tl(III was 2.5%. The detection limit based on 3Sb for Tl(III in the original solution was 2.1 ng mL−1. The proposed method has been applied for the determination of trace amounts of thallium in hair samples and satisfactory results were obtained.

  12. Improving TL dosimetry for external radiotherapy

    International Nuclear Information System (INIS)

    Bustos, S.R.; Velez, G.; Rubio, M.

    1998-01-01

    Full text: In vivo thermoluminescence dosimetry (TLD) has always been one of the most accurate dosimetry method for external radiotherapy control, but the delay in the response is a well know drawback when it is applied. In this work we show some improvements and demonstrate that keeping the precision and accuracy of this technique, it is possible to obtain a response in few hours. Harshaw 4000 TL reader and LiF TLD-100 dosimeters, chips (3,1 x 3,1 x 0,9 mm 3 ) and rods (1 x 1 x 6 mm 3 ) have been used. The thermal treatment necessary to reuse the TLD is only 1h at 400 degree C, by using a glow curve analyser developed at the Ciemat (Spain), that allows a complete, prompt and precise identification of the individuals peaks. The dosimeters are periodically and individually calibrated. We also have study the factors contributing to the relation TL-dose like linearity, energy correction, directional response and fading. All those results are included into an Excel worksheet which automatically give us the dose resulting from the TL reading (peaks areas 4 and 5). The obtained uncertainty is better than 5%. The TLD already irradiated in radiotherapy institutions distant 30-40 Km from our centre can be read and analysed in about 3-4 hours. These facts render our methods rapid and allow a better control of radiotherapy treatment even if it is bi-fractionated. (author) [es

  13. Characterization and analysis of NaI(Tl) and BGO detectors

    International Nuclear Information System (INIS)

    Harrison, J.R.

    1994-01-01

    There have been many studies concerning the performance characteristics of NaI(Tl) and BGO scintillating crystals, most of which generate data by algorithms rather than from experimentation. Those studies which do deal with collected data, however, usually test only a few detecting units. It was, therefore, the purpose of this project to develop a characterization method and to characterize a large number of scintillators of various sizes and histories as well as to create a performance profile based on the data collected. The energy ranges at which the detectors show relatively good resolution % and photo peak efficiency was also desired for future reference. Enough statistical data was collected and analyzed so that a differentiation between those detectors which perform well and those that do not can be made

  14. Thermodynamic Study of Tl6SBr4 Compound and Some Regularities in Thermodynamic Properties of Thallium Chalcohalides

    Directory of Open Access Journals (Sweden)

    Dunya Mahammad Babanly

    2017-01-01

    Full Text Available The solid-phase diagram of the Tl-TlBr-S system was clarified and the fundamental thermodynamic properties of Tl6SBr4 compound were studied on the basis of electromotive force (EMF measurements of concentration cells relative to a thallium electrode. The EMF results were used to calculate the relative partial thermodynamic functions of thallium in alloys and the standard integral thermodynamic functions (-ΔfG0, -ΔfH0, and S0298 of Tl6SBr4 compound. All data regarding thermodynamic properties of thallium chalcogen-halides are generalized and comparatively analyzed. Consequently, certain regularities between thermodynamic functions of thallium chalcogen-halides and their binary constituents as well as degree of ionization (DI of chemical bonding were revealed.

  15. Exploring the thermoelectric and magnetic properties of uranium selenides: Tl2Ag2USe4 and Tl3Cu4USe6

    International Nuclear Information System (INIS)

    Azam, Sikander; Khan, Saleem Ayaz; Din, Haleem Ud; Khenata, Rabah; Goumri-Said, Souraya

    2016-01-01

    The electronic, magnetic and thermoelectric properties of Tl 2 Ag 2 USe 4 and Tl 3 Cu 4 USe 6 compounds were investigated using the full potential linear augmented plane wave (FP-LAPW) method based on the density functional theory (DFT). The exchange correlation was treated with the generalized gradient approximation plus optimized effective Hubbard parameter and spin–orbit coupling (GGA+U+SOC). The present uranium selenides show narrow direct energy band gap values of 0.7 and 0.875 eV for Tl 2 Ag 2 USe 4 and Tl 3 Cu 4 USe 6 respectively. For both selenides U-d/f states are responsible for electrical transport properties. Uranium atoms were the most contributors in the magnetic moment compared to other atoms and show ferromagnetic nature. The spin density isosurfaces show the polarization of neighboring atoms of Uranium, such as silver/copper and selenium. Thermoelectric calculations reveal that Tl 3 Cu 4 USe 6 is more suitable for thermoelectric device applications than Tl 2 Ag 2 USe 4 . - Highlights: • Electronic, magnetic and thermoelectric properties of uranium selenides are investigated with DFT. • They show a narrow direct energy band gap of 0.7 and 0.875 eV. • U-d/f states are responsible for electrical transport properties. • Tl 3 Cu 4 USe 6 is more suitable for thermoelectric device applications than Tl 2 Ag 2 USe 4 .

  16. Color centers in heavily irradiated CsI(Tl) crystals

    International Nuclear Information System (INIS)

    Yakovlev, V.; Meleshko, A.; Trefilova, L.

    2008-01-01

    The absorption and luminescence properties of CsI(Tl) crystals colored by irradiation are studied by the method of the time-resolved spectroscopy. The scheme of the electron transitions in CsI(Tl) crystal is suggested to explain the appearance of the color centers under exposure to the near-UV light. It is established that either of the two types activator color centers holds the charge carrier with opposite sign. The model of the hole Tl 2+ v c - activator color center is suggested. According to the model the positive charge of Tl 2+ ion is compensated by the negative charge of a close cation vacancy v c - . The color center emission reveals in the cathode-luminescence spectrum of the colored CsI(Tl) crystal. The high-dose irradiation of CsI(Tl) crystal results in the reduction of the decay time of the near-thallium self-trapped excitons (STE) emission. The decay kinetics of Tl 2+ v c - emission contains the time components typical for the decay kinetics of near-thallium STE emission. The reason of the observed effects is the energy transfer from the near-thallium STE excitons to the color centers via the inductive-resonant mechanism

  17. Ab initio calculations of the electron spectrum and density of states of TlFeS{sub 2} and TlFeSe{sub 2} crystals

    Energy Technology Data Exchange (ETDEWEB)

    Ismayilova, N. A., E-mail: ismayilova-narmin-84@mail.ru; Orudjev, H. S.; Jabarov, S. H. [Azerbaijan National Academy of Sciences, Institute of Physics (Azerbaijan)

    2017-04-15

    The results of ab initio calculations of the electron spectrum of TlFeS{sub 2} and TlFeSe{sub 2} crystals in the antiferromagnetic phase are reported. Calculations are carried out in the context of the density functional theory. The origin of the bands of s, p, and d electron states of Tl, Fe, S, and Se atoms is studied. It is established that, in the antiferromagnetic phase, the crystals possess semiconductor properties. The band gaps are found to be 0.05 and 0.34 eV for TlFeS{sub 2} and TlFeSe{sub 2} crystals, respectively.

  18. The unfolding of NaI(Tl) γ-ray spectrum based on maximum likelihood method

    International Nuclear Information System (INIS)

    Zhang Qingxian; Ge Liangquan; Gu Yi; Zeng Guoqiang; Lin Yanchang; Wang Guangxi

    2011-01-01

    NaI(Tl) detectors, having a good detection efficiency, are used to detect gamma rays in field surveys. But the poor energy resolution hinders their applications, despite the use of traditional methods to resolve the overlapped gamma-ray peaks. In this paper, the maximum likelihood (ML) solution is used to resolve the spectrum. The ML method,which is capable of decomposing the peaks in energy difference of over 2/3 FWHM, is applied to scale NaI(Tl) the spectrometer. The result shows that the net area is in proportion to the content of isotopes and the precision of scaling is better than the stripping ration method. (authors)

  19. The precise measurement of TL isotopic compositions by MC-ICPMS: Application to the analysis of geological materials and meteorites.

    Science.gov (United States)

    Rehkämper, Mark; Halliday, Alex N.

    1999-07-01

    The precision of Tl isotopic measurements by thermal ionization mass spectrometry (TIMS) is severely limited by the fact that Tl possesses only two naturally occurring isotopes, such that there is no invariant isotope ratio that can be used to correct for instrumental mass discrimination. In this paper we describe new chemical and mass spectrometric techniques for the determination of Tl isotopic compositions at a level of precision hitherto unattained. Thallium is first separated from the geological matrix using a two-stage anion-exchange procedure. Thallium isotopic compositions are then determined by multiple-collector inductively coupled plasma-mass spectrometry with correction for mass discrimination using the known isotopic composition of Pb that is admixed to the sample solutions. With these procedures we achieve a precision of 0.01-0.02% for Tl isotope ratio measurements in geological samples and this is a factor of ≥3-4 better than the best published results by TIMS. However, without adequate precautions, experimental artifacts can be generated that result in apparent Tl isotopic fractionations of up to one per mil. Analysis of five terrestrial samples indicate the existence of Tl isotopic variations related to natural fractionation processes on the Earth. Two of the three igneous rocks analyzed in this study display Tl isotopic compositions indistinguishable from our laboratory standard, the reference material NIST-997 Tl. A third sample, however, is characterized by ɛ Tl ≈ 2.5 ± 1.5, where ɛ Tl represents the deviation of the 205Tl/ 203Tl ratio of the sample relative to NIST-997 Tl in parts per 10 4. Even larger deviations were identified for two ferromanganese crusts from the Pacific Ocean, which display ɛ Tl-values of +5.0 ± 1.5 and +11.7 ± 1.3. We suggest that the large variability of Tl isotopic compositions in the latter samples are caused by low-temperature processes related to the formation of the Fe-Mn crusts by precipitation and

  20. TL and OSL dosimetric properties of Opal gemstone for gamma radiation dosimetry

    International Nuclear Information System (INIS)

    Antonio, Patrícia L.; Gronchi, Claudia C.; Oliveira, Raquel A.P.; Khoury, Helen J.; Caldas, Linda V.E.

    2016-01-01

    In this work, the response of the natural material Opal was studied in relation to its thermoluminescence (TL) and optically stimulated luminescence (OSL), after exposure to the gamma radiation of a "6"0Co source. The structure of the powdered Opal was verified using the X-ray diffraction, scanning electronic microscopy and energy-dispersive X-ray spectroscopy techniques. The material, in its stone form, was turned into powder and mixed to Teflon (also in powder) in three different concentrations, and then pellets were manufactured. The aim of this work was to evaluate the response of these pellets in high-doses of gamma radiation beams, and to observe their possible application as dosimeters, using the TL and OSL techniques. The dosimetric properties of the samples were analyzed by means of different tests, as: TL emission curves and OSL signal decay curves, reproducibility of TL and OSL response, minimum detectable dose, TL and OSL dose–response curves (5 Gy–10 kGy), and fading. The results obtained in this work, for the TL and OSL phenomena, demonstrated that the pellets of Opal + Teflon present an adequate performance e possibility of use as dosimeters in beams of high-dose gamma radiation. - Highlights: • The XRD, SEM and EDX techniques were used to investigate powdered Opal. • Pellets of three different concentrations of Opal and Teflon were studied. • The dosimetric properties of the Opal + Teflon pellets were verified. • TL and OSL techniques were used to analyze the characteristics of the pellets. • Pellets of concentration of 2:1 (Opal:Teflon) presented the most adequate results.

  1. ESR and TL age determination of caliche nodules

    Energy Technology Data Exchange (ETDEWEB)

    Oezer, A.M. (Middle East Technical Univ., Ankara (Turkey)); Wieser, A.; Goeksu, H.Y.; Mueller, P.; Regulla, D.F. (Gesellschaft fuer Strahlen- und Umweltforschung mbH Muenchen, Neuherberg (Germany, F.R.). Inst. fuer Strahlenschutz); Erol, O. (Istanbul Univ. (Turkey). School of Geography and Marine Sciences)

    1989-01-01

    Feasibility of dating caliche nodules by ESR and TL is investigated. For both methods the properties of the dating signal are described. Chemical composition as well as TL glow curves of caliches originating from different localities exhibit some differences. Due to the complexity of the TL glow curves, some samples required a special post-annealing procedure in order to resolve the main TL peak for age determination. Typical ESR calcite signals do not exist in caliche, therefore usefulness of the g=2.0040 ESR signal is studied. The results of TL and ESR ages are found to be compatible except for two samples. Possible causes of the discrepancy in these samples are discussed. It is shown that, with proper treatment of the radiation-induced signals, it was possible to date caliche formations older than 350 ka, which is not achievable with other methods like uranium series disequilibrium and/or radiocarbon dating. (author).

  2. ESR and TL age determination of caliche nodules

    International Nuclear Information System (INIS)

    Oezer, A.M.; Wieser, A.; Goeksu, H.Y.; Mueller, P.; Regulla, D.F.; Erol, O.

    1989-01-01

    Feasibility of dating caliche nodules by ESR and TL is investigated. For both methods the properties of the dating signal are described. Chemical composition as well as TL glow curves of caliches originating from different localities exhibit some differences. Due to the complexity of the TL glow curves, some samples required a special post-annealing procedure in order to resolve the main TL peak for age determination. Typical ESR calcite signals do not exist in caliche, therefore usefulness of the g=2.0040 ESR signal is studied. The results of TL and ESR ages are found to be compatible except for two samples. Possible causes of the discrepancy in these samples are discussed. It is shown that, with proper treatment of the radiation-induced signals, it was possible to date caliche formations older than 350 ka, which is not achievable with other methods like uranium series disequilibrium and/or radiocarbon dating. (author)

  3. Standardization of 201Tl and 55Fe radionuclides in a 4 (PC)-NaI(Tl) coincidence system

    International Nuclear Information System (INIS)

    Pires, Carlos Augusto

    2008-01-01

    In the present work the procedure for the standardization of radionuclides using the 4π(PC)-NaI(Tl) coincidence system was developed. The radionuclides selected were 201 Tl, used in nuclear medicine, and 55 Fe primary standard source, used for x-ray spectrometers calibration. The 4π(PC)-NaI(Tl) is composed of a 4 proportional counter operated at 0.1MPa coupled to two NaI(Tl) crystals. The 201 Tl decays by electron capture process followed by a prompt gamma-ray. The disintegration rate was determined by extrapolation technique using two methods: electronic discrimination and external absorbers. The radioactive sources were prepared in a 20 μg cm -2 thick Collodion film. The conventional electronic system was used. The observed events were registered by the TAC method. The 55 Fe decays by electron capture process to the ground state of 55 Mn, emitting x rays with around 6 keV. The standardization was obtained by the tracing method. This technique was applied using two radionuclides, which decay by electron capture process followed by a prompt gamma-ray, namely 51 Cr and 54 Mn, as tracers. Measurements with 1 and 2 aluminum foils, each 150 g cm-2 thick were carried out. The activity was obtained by extrapolation for zero thickness Al foil. The uncertainties were treated by means of matrix covariance methodology and takes into account all correlations involved. (author)

  4. Electrochemically produced alumina as TL detector

    International Nuclear Information System (INIS)

    Osvay, M.

    1996-01-01

    The goal of this work was to compare the TL properties of various electrochemically produced alumina layers (E-AIO) in order to investigate the effect of the electrolyte and the Mg content on the alloys. It has been found that the TL sensitivity of oxidised layers is more influenced by the type of electrolyte, than by the composition of alloy. Hard oxide layer evolved in reduction electrolyte has rather different character compared to other alumina production investigated. The effect of reducing media seems to be very important during preparation of alumina layer. One of the advantages properties of E-AIO is, that it serve a promising method to increase the measuring range of TL method above 10 kGy as well. (author)

  5. Pulse shaper for scintillation detectors with NaI(Tl) or CsI(Tl) crystals

    International Nuclear Information System (INIS)

    Novisov, B.S.; Maksimenko, A.S.; Baryshev, A.V.; Zhukov, A.V.

    1978-01-01

    The basic circuit of a signal shaper for scintillation detectors with NaI(Tl) and CsI(Tl) crystals is described. To increase amplitude resolution, it is suggested to integrate not the whole charge at the photomultiplier output, but a part of the charge during the initial 100 ns of the current pulse; the remaining part of the current signal is compensated directly at the photomultiplier anode by means of an electric circuit. The principal elements of the spectrometric signal shaper include an input transistor amplifier, a compensation circuit, a key element, a shaper amplifier of time pulses, a shaper of signal duration for controlling the key element, and an output spectrometric amplifier. This device, being used, one can shape pulses at durations of 100 ns and more. The shaper restoration time does not exceed 50 ns. When the shaper operates with NaI(Tl) crystals and at counting rate of 10 6 pulse/s, the amplitude resolution with and without the compensation circuit is 17% and 21% respectively

  6. Study of the functional characteristics of a NaI(Tl) scintillator gamma spectrometer

    International Nuclear Information System (INIS)

    Jesus Barbosa, S. de.

    1983-01-01

    Functional characteristics (resolution, stability, linearity, counting efficiency) of a NaI(Tl) scintillator gamma spectrometer were studied. Diagrams were plotted and several standard sources ( 241 Am, 109 Cd, 57 Co, 137 Cs, 54 Mn, 22 Na) with gamma energies ranging from 60 to 1275 KeV were used. (C.L.B.) [pt

  7. Remote TL and OSL for asteroid and meteorite study

    International Nuclear Information System (INIS)

    Takaki, Shunji; Ikeya, Motoji; Yamanaka, Chihiro

    1997-01-01

    Thermoluminescence (TL) and optically stimulated luminescence (OSL) of the Allende meteorite have been studied using infrared CO 2 laser light as a heat source and He-Ne laser light to excite the material, respectively from a long distance. New techniques of remote TL (R-TL) and remote OSL (R-OSL) have been developed for future remote dating from a long distance in a planetary survey. The upper limits of the distance for R-TL and R-OSL were estimated using the laboratory TL signal of the meteorite peaking at 320 o C: about 400 photons s -1 for the R-TL and 60 photons s -1 for R-OSL at a distance of 1 km using a laser beam with the divergence of 0.1 mrad at powers of 100 and 1 W, respectively. An age limit of 10 5 or 10 6 years due to the signal saturation and the objects heterogeneity, as expected from previous studies, may make the asteroid survey difficult but would still help to investigate the surface activities of icy planets and satellites in outer planet worlds. (author)

  8. Serial right ventricle 201Tl imaging after exercise: relation to anatomy of the right coronary artery

    International Nuclear Information System (INIS)

    Brown, K.A.; Boucher, C.A.; Okada, R.D.; Strauss, H.W.; McKusick, K.A.; Pohost, G.M.

    1982-01-01

    The relation of the appearance of the right ventricle on serium 201 Tl myocardial imaging to coronary artery anatomy was examined in 88 consecutive patients undergoing exercise 201 Tl testing and coronary angiography for the evaluation of chest pain. Transient defects in the right ventricle were found in 8 patients. All had high grade (greater than or equal to 90%) stenosis of the proximal right coronary artery. Nonvisualization of right ventricular (RV) activity occurred in 10 patients. Nine of the 10 (90%) had significant (greater than or equal to 50% stenosis) disease of the proximal right coronary artery and 7 (70%) had high grade stenosis. The right ventricle appeared normal in 70 patients. Twenty-nine (41%) of these patients had significant proximal right coronary artery disease. Right ventricular appearance was not affected by the presence or absence of disease of the left anterior descending or left circumflex artery or by the appearance of the left ventricle. Thus, with serial RV thallium-201 myocardial imaging after exercise, we found that (1) RV transient defects suggest the presence of high grade proximal right coronary artery stenosis, (2) non-visualization of RV activity also predicts significant proximal right coronary disease, and (3) the right ventricle frequently appears normal despite proximal right coronary artery disease and therefore this finding does not exclude such disease

  9. Structure and scintillation properties of CsI(Tl) films on Si single crystal substrates

    Energy Technology Data Exchange (ETDEWEB)

    Guo, Lina [State Key Laboratory of Electronic Thin Films and Integrated Devices, School of Optoelectronic Information, University of Electronic Science and Technology of China, Chengdu 610054 (China); Liu, Shuang, E-mail: shuangliu@uestc.edu.cn [State Key Laboratory of Electronic Thin Films and Integrated Devices, School of Optoelectronic Information, University of Electronic Science and Technology of China, Chengdu 610054 (China); Chen, Dejun; Zhang, Shangjian; Liu, Yong; Zhong, Zhiyong [State Key Laboratory of Electronic Thin Films and Integrated Devices, School of Optoelectronic Information, University of Electronic Science and Technology of China, Chengdu 610054 (China); Falco, Charles M. [University of Arizona, College of Optical Sciences, AZ 85721 (United States)

    2016-10-30

    Highlights: • We obtained the desired micro-columnar structure of CsI(Tl) films on the orienting Si substrates. • We improved the micro-columnar structure of CsI(Tl) films under the relatively large deposition rate through using the substrate with a pre-deposited CsI nanolayer. • We modeled the interface structures between the CsI(Tl) films with (200) and (310) orientation and Si(111) substrates to explain the preferred orientation of film under the influence of the orienting substrate significantly. • We gained a new spectrum of the CsI(Tl) films peaked at 740 nm wavelength. - Abstract: CsI(Tl) scintillation films fabricated on glass substrates are widely applied for X-ray imaging because their ability to grow in micro-columnar structure and proper emission wavelength matching CCD cameras. But the coupling process between the CsI(Tl) films and Si-based photo detector would cause coupling loss. In this work, CsI(Tl) films were deposited on the orienting Si substrates and the Si substrates covered by the pre-deposited CsI nanolayers. Structure and scintillation properties of films were examined by using scanning electron microscopy, X-ray diffraction, photoluminescence and radioluminescent spectrum. The films deposited on the orienting Si substrates show the micro-columnar morphology with perfect single crystalline structure and the photoluminescence spectra with bimodal distribution. The performances of the films prepared on the pre-deposited CsI nanolayer, containing micro-columns structure and the light yield are improved.

  10. Structure and scintillation properties of CsI(Tl) films on Si single crystal substrates

    International Nuclear Information System (INIS)

    Guo, Lina; Liu, Shuang; Chen, Dejun; Zhang, Shangjian; Liu, Yong; Zhong, Zhiyong; Falco, Charles M.

    2016-01-01

    Highlights: • We obtained the desired micro-columnar structure of CsI(Tl) films on the orienting Si substrates. • We improved the micro-columnar structure of CsI(Tl) films under the relatively large deposition rate through using the substrate with a pre-deposited CsI nanolayer. • We modeled the interface structures between the CsI(Tl) films with (200) and (310) orientation and Si(111) substrates to explain the preferred orientation of film under the influence of the orienting substrate significantly. • We gained a new spectrum of the CsI(Tl) films peaked at 740 nm wavelength. - Abstract: CsI(Tl) scintillation films fabricated on glass substrates are widely applied for X-ray imaging because their ability to grow in micro-columnar structure and proper emission wavelength matching CCD cameras. But the coupling process between the CsI(Tl) films and Si-based photo detector would cause coupling loss. In this work, CsI(Tl) films were deposited on the orienting Si substrates and the Si substrates covered by the pre-deposited CsI nanolayers. Structure and scintillation properties of films were examined by using scanning electron microscopy, X-ray diffraction, photoluminescence and radioluminescent spectrum. The films deposited on the orienting Si substrates show the micro-columnar morphology with perfect single crystalline structure and the photoluminescence spectra with bimodal distribution. The performances of the films prepared on the pre-deposited CsI nanolayer, containing micro-columns structure and the light yield are improved.

  11. Right ventricular visualization by Tl-201 myocardial scintigraphy in chronic obstructive pulmonary disease

    Energy Technology Data Exchange (ETDEWEB)

    Fujii, Tadashige; Tanaka, Masao; Takeda, Masashi; Matsuzawa, Yukinori; Handa, Kenjiro; Yoshimura, Kazuhiko [Shinshu Univ., Matsumoto, Nagano (Japan). Faculty of Medicine

    1993-04-01

    Tl-201 myocardial scintigraphy was performed in 130 patients with chronic obstructive pulmonary disease (COPD) to evaluate right ventricular hypertrophy, and the clinical significance of this method was studied. Tl-201 uptake ratios of the right ventricle, which represents the ratio of total counts of the right ventricle to counts of the administered dose of Tl-201, was higher in COPD, especially in pulmonary emphysema and B type COPD by Burrows classification than in controls. The grade of visualization of the right ventricle by visual assessment (RVV) was marked (+++) in only a few cases and moderate (++) in many cases (more than 80%) in all diseases except bronchial asthma. The incidence of right ventricular hypertrophy by electrocardiogram, right-sided heart failure and marked dyspnea (Hugh-Jones 4[center dot]5) were very low in cases with RVV grade ++ and very high in cases with +++. The grade of RVV was related to the severity of pulmonary perfusion impairment, although in diffuse panbronchiolitis the RVV was relatively slight compared with the impairment of perfusion. May parameters of pulmonary function such as %VC, FEV1.0%, RV/TLC, V25, %DLCO, Raw, [Delta]N[sub 2] and PaO[sub 2] showed abnormal values in patients with RVV grade of (++) or (+++) in all diseases except bronchial asthma. In COPD, Tl-201 myocardial scintigraphy seems to be useful for assessment of right ventricular overloading, and for follow-up observation and differentiation between cor pulmonale and right ventricular hypertrophy secondary to cardiac diseases by observing Tl-201 uptake of the lung and left ventricle. (author).

  12. Right ventricular visualization by Tl-201 myocardial scintigraphy in chronic obstructive pulmonary disease

    International Nuclear Information System (INIS)

    Fujii, Tadashige; Tanaka, Masao; Takeda, Masashi; Matsuzawa, Yukinori; Handa, Kenjiro; Yoshimura, Kazuhiko

    1993-01-01

    Tl-201 myocardial scintigraphy was performed in 130 patients with chronic obstructive pulmonary disease (COPD) to evaluate right ventricular hypertrophy, and the clinical significance of this method was studied. Tl-201 uptake ratios of the right ventricle, which represents the ratio of total counts of the right ventricle to counts of the administered dose of Tl-201, was higher in COPD, especially in pulmonary emphysema and B type COPD by Burrows classification than in controls. The grade of visualization of the right ventricle by visual assessment (RVV) was marked (+++) in only a few cases and moderate (++) in many cases (more than 80%) in all diseases except bronchial asthma. The incidence of right ventricular hypertrophy by electrocardiogram, right-sided heart failure and marked dyspnea (Hugh-Jones 4·5) were very low in cases with RVV grade ++ and very high in cases with +++. The grade of RVV was related to the severity of pulmonary perfusion impairment, although in diffuse panbronchiolitis the RVV was relatively slight compared with the impairment of perfusion. May parameters of pulmonary function such as %VC, FEV1.0%, RV/TLC, V25, %DLCO, Raw, ΔN 2 and PaO 2 showed abnormal values in patients with RVV grade of (++) or (+++) in all diseases except bronchial asthma. In COPD, Tl-201 myocardial scintigraphy seems to be useful for assessment of right ventricular overloading, and for follow-up observation and differentiation between cor pulmonale and right ventricular hypertrophy secondary to cardiac diseases by observing Tl-201 uptake of the lung and left ventricle. (author)

  13. X-ray dosimetry of TlGaSe2 single crystals

    International Nuclear Information System (INIS)

    Kerimova, E.M.; Mustafaeva, S.N.; Mamedbeili, S.D.; Jabarov, J.N.; Iskenderova, P.M.; Kazimov, S.B.

    2002-01-01

    TlGaSe 2 compound belongs to group of layered semiconductors of A 3 B 3 C 2 6 -type. Photoelectric and optical properties of TlGaSe 2 single crystals were investigated in detail. Influence of gamma-, electron and neutron radiation on photoelectric properties of TlGaSe 2 single crystals is investigated too. The present work deals with experimental results relative to X-ray dosimetric characteristics of TlGaSe 2 crystals at 300 K. X-ray conductivity and X-ray dosimetric characteristic measurements are carried out in low load resistance regime. The source of X-ray radiation is the installation of X-ray diffraction analysis (URS-55a) with the BCV-2(Cu). Intensity of X-ray radiation (E) is regulated by measurement with current variation in tube at each given value of X-ray radiation dose E (R/min) are measured by crystal dosimeter DRGZ-02. X-ray conductivity coefficients K σ characterising X-ray sensitivity of investigated crystals are determined as the relative change of conductivity under X-ray radiation a per dose. There have been determined values of characteristic coefficients of TlGaSe 2 single crystal X-ray conductivity at different values of accelerating voltage (V a ) on the tube and corresponding doses of X-ray radiation. Analysis of obtained data showed that X-ray conductivity coefficients K σ in studied crystals are regularly decreased (from 0.276 to 0.033) as with the rise of dose (E=0.75-78.0 R/min) as with the increase of values of V a on X-ray tube (V a =254-50 keV). One of the possible reasons of observed regularities is that X-ray conductivity in investigated crystals, especially at comparatively low V a is due predominantly to radiation of thin layer of crystal. In this case with the rise of radiation intensity there have been started to prevail the mechanism of surface quadratic recombination which leads to observed decrease of X-ray conductivity. With the rise of accelerating potential 'effective hardness' is increased, as a result of which there

  14. The superconductor (Tl,Hg,Ca)2(Ba,Sr)2(Ca,Sr,Tl)Cu2O7.6

    International Nuclear Information System (INIS)

    Valldor, M.; Bryntse, I.; Morawski, A.

    2002-01-01

    In the title 2212-type superconductor (thallium mercury calcium barium strontium copper oxide), which contains both Tl and Hg in the charge reservoir (CR), Sr is located at both alkali-earth (AE) metal sites. Ca enters the CR at the same time as Tl shares the smaller AE site, which increases the apical Cu-Cu distance significantly. The structure causes the superconducting Cu-O layers to become significantly puckered. (orig.)

  15. The TL and OSL study of hydroxyapatites for dosimetric applications

    International Nuclear Information System (INIS)

    Alencar, Marcus A. Vallim de

    2009-01-01

    The hydroxyapatite, the principal mineral component of the bone and tooth enamel, is one of the dosimetric materials that has distinguished itself in the high dose and accidents dosimetry, as well as in the dating, for the Electron Paramagnetic Resonance (EPR) technique. For this reason, the hydroxyapatite could also be used as Thermoluminescence (TL) and Optically Stimulated Luminescence (OSL) dosimeter in the dosimetry of high doses and accidents, and also in the archaeological and geological dating. This work presents a brief study of the TL and OSL behaviour of the B type synthetic carbonated hydroxyapatite, observing the possibility to use this material in TL and OSL dosimetry. The samples were irradiated to a dose of 100 Gy and 1000 Gy, and the TL and OSL measurements were obtained by the RISOE TL/OSL reader, model TL/OSL-DA-15B. The first results demonstrate the presence of three peaks in the TL glow curve in the temperatures of 100 deg C, 150 deg C and 280 deg C. The synthetic carbonated hydroxyapatite also presents an OSL signal when the sample is stimulated with blue light and a small OSL signal for stimulation with infrared light (IR). These results indicate the possibility of this synthetic carbonated hydroxyapatite to be used as dose indicator material using the TL and OSL techniques. (author)

  16. Relative thermoluminescent efficiencies proton/gamma and helium/gamma of high temperature peaks in TLD-100 dosemeters; Eficiencias termoluminiscentes relativas proton/gamma y helio/gamma de picos de alta temperatura en dosimetros TLD-100

    Energy Technology Data Exchange (ETDEWEB)

    Flores M, E.; Avila, O.; Rodriguez V, M. [ININ, 52750 La Marquesa, Estado de Mexico (Mexico); Massillon, J.L.G.; Buenfil A, E.; Ruiz T, C.; Brandan, M.E. [IFUNAM, 04500 Mexico D.F. (Mexico); Gamboa De Buen, I. [ICN-UNAM, 04500 Mexico D.F. (Mexico)

    2007-07-01

    This work presents measures of relative thermoluminescent efficiency of those high temperature peaks of TLD-100 dosemeters exposed to protons of 1.5 MeV and to helium nuclei of 3 and 7.5 MeV. A rigorous reading and of deconvolution protocol was used for the calculation of the TL efficiencies. Additionally an Excel program that facilitated the deconvolution adjustment process of the glow curves was elaborated. (Author)

  17. The correlation of fast OSL component with the TL peak at 3250C in quartz of various origins

    International Nuclear Information System (INIS)

    Kitis, G.; Kiyak, N.; Polymeris, G.S.; Tsirliganis, N.C.

    2010-01-01

    The fast component of the optically stimulated luminescence (OSL) signal in quartz is the basic tool for the optical dating. Its relation with the thermoluminescence (TL) glow-peak at about 325 deg. C is well established for naturally irradiated quartz. This relationship is also an important part of a general model for quartz on which many theoretical simulations of various OSL experimental results have been based. In the present work this relationship is systematically investigated in nine quartz samples of different origin. The linearly modulated OSL (LM-OSL) curves of all quartz samples for stimulation time less than 50 s consists of two components discriminated easily by a computerized curve deconvolution (CCD) analysis. By comparing the un-bleached to the respective bleached TL glow-curve, it is found that the system of these two fast OSL components is directly related with only a small portion of the electron traps responsible for the TL glow-peaks in the temperature region 200-400 0 C. By increasing the stimulation times, besides the two fast components, the medium and the slow components are also obtained. The medium and slow components are clearly related with the main body of the electron traps responsible for TL glow-peaks in the same temperature region 200-400 0 C. Despite their different origin all quartz samples show an appreciable homogeneity concerning the number and time position of the individual components, whereas, the relative TL/OSL intensities vary strongly from sample to sample with the integrated TL intensity being generally much less than the integrated OSL intensity.

  18. Temperature dependence of positron annihilation parameters in Tl-Ba-Ca-Cu-O superconductors

    International Nuclear Information System (INIS)

    Sundar, C.S.; Bharathi, A.; Ching, W.Y.; Jean, Y.C.; Hor, P.H.; Meng, R.L.; Huang, Z.J.; Chu, C.W.

    1990-01-01

    The results of positron lifetime and Doppler broadened line-shape parameter measurements as a function of temperature, across T c , in the Tl-Ba-Ca-Cu-O superconductors are presented. The bulk lifetime in the normal state is found to decrease with the increase in the number of CuO 2 layers. Different temperature dependencies of the annihilation parameters are observed in the various Tl systems containing different numbers of CuO 2 layers. In the Tl 2 Ba 2 Ca 2 Cu 3 O 10 system, an increase in lifetime is observed below T c , whereas in Tl 2 Ba 2 CaCu 2 O 8 , a decrease in lifetime is seen below T c . In the Tl 2 Ba 2 CuO 6 system, the lifetime is observed to be temperature independent. The different temperature variations of positron annihilation parameters are discussed in the light of the positron density distribution, obtained with use of the results of the self-consistent orthogonalized linear combination of atomic orbitals band-structure calculations. It is argued that the different temperature dependencies of the annihilation parameters is related to the positron density distribution within the unit cell and arise due to local charge transfer in the vicinity of the CuO 2 layer in the superconducting state

  19. Detailed α -decay study of 180Tl

    Science.gov (United States)

    Andel, B.; Andreyev, A. N.; Antalic, S.; Barzakh, A.; Bree, N.; Cocolios, T. E.; Comas, V. F.; Diriken, J.; Elseviers, J.; Fedorov, D. V.; Fedosseev, V. N.; Franchoo, S.; Ghys, L.; Heredia, J. A.; Huyse, M.; Ivanov, O.; Köster, U.; Liberati, V.; Marsh, B. A.; Nishio, K.; Page, R. D.; Patronis, N.; Seliverstov, M. D.; Tsekhanovich, I.; Van den Bergh, P.; Van De Walle, J.; Van Duppen, P.; Venhart, M.; Vermote, S.; Veselský, M.; Wagemans, C.

    2017-11-01

    A detailed α -decay spectroscopy study of 180Tl has been performed at ISOLDE (CERN). Z -selective ionization by the Resonance Ionization Laser Ion Source (RILIS) coupled to mass separation provided a high-purity beam of 180Tl. Fine-structure α decays to excited levels in the daughter 176Au were identified and an α -decay scheme of 180Tl was constructed based on an analysis of α -γ and α -γ -γ coincidences. Multipolarities of several γ -ray transitions deexciting levels in 176Au were determined. Based on the analysis of reduced α -decay widths, it was found that all α decays are hindered, which signifies a change of configuration between the parent and all daughter states.

  20. Response function study of a scintillator detector of NaI(Tl)

    International Nuclear Information System (INIS)

    Villa, Marcelo Barros; Costa, Alessandro Martins da

    2014-01-01

    In measurements of gamma rays with Nai (Tl) scintillator, the detectors output data are pulse height spectra, that corresponding to distorted information about the radiation source due to various errors associated with the crystal scintillation process and electronics associated, instead of power spectra photons. Pulse height spectra are related to the real power spectra by means of scintillator detector response function NaI (Tl). In this work, the response function for a cylindrical crystal of Nal (Tl) of 7,62 x 7,62 cm (diameter x length) was studied, by Monte Carlo method, using the EGSnrc tool to model the transport of radiation, combined with experimental measurements. An inverse response matrix, even with the energy of the square root, which transforms the pulse height spectrum of photon energy spectrum was obtained. The results of this transformation of pulse height spectrum for photon energy spectrum is presented, showing that the methodology employed in this study is suitable

  1. The adsorption of Tl(I), Au(III), Cu(II) and the separation of 199Tl from alpha bombardment of gold target with PDB-18C6

    International Nuclear Information System (INIS)

    Zhou Dehai; Zhou Jimeng

    1989-01-01

    The adsorptive behavior of polymer of methyl aldehyde of dibenzo-18-crown-6 (PDB-18C6) in hydrochloric acid medium is studied and it is shown that the adsorption of T1(I), Au(III), and Cu(II) depends on the particle size of the crown ether resins, hydrochloric acid concentration and amount of the crown ether resins used. The difference in the adsorption behavior of different particle sizes of crown ether resins may be used for separating Tl(I), Au(III), and Cu(II) ions. The best eluant of Tl(I) and Au(III) is 0.4 mol/l perchloric acid and 2-ethoxy-ethanol. The recovery for Tl(I) is 82-98.8%. The gold target is bombarded in a 1.2 m cyclotron with 25-27 MeV α-particle with a cumulative beam intensities of 27μA·h, and 199 Tl is separated from the gold target with PDB-18C6. γ-spectrometry has shown that the Tl obtained is 199 Tl of high purity containing only about 0.50% 200 Tl

  2. A clinical study of gated simultaneous rest 201Tl/stress 99Tcm-sestamibi dual isotope myocardial perfusion imaging

    International Nuclear Information System (INIS)

    Tang Anwu; Qiao Shuixian; Luo Yaowu; Liang Xiaolin

    2002-01-01

    Objective: To investigate a modified gated radionuclide myocardial tomography in methodology for raising the sensitivity and efficiency of detecting myocardial ischemia. Methods: One hundred and three patients were involved and divided into two groups: coronary artery disease (CAD) patient 37, non-CAD patient 66. 201 Tl 111 MBq was injected intravenously 5 min before stress, the patient exercised with ergometer following the modified Bruce protocol, and was injected 99 Tc m -sestamibi at the peak of stress. 45 min later, the simultaneous dual energy peak gated acquisition was then performed. Stress ( 99 Tc m -sestamibi) and rest ( 201 Tl) images were reconstructed. Results: Positive findings were seen in 35/37 (94.6%) in CAD group and 7/66 (10.6%) in non-CAD, respectively; LVEF, EDV and ESV of two groups were (52.33+-16.26)%, (70.45+-28.12) mL, (33.35 +- 18.86) mL and (61.76 +- 9.38)%, (60.45 +- 18.18) mL, (23.30 +- 11.09) mL, respectively. Conclusion: The simultaneous stress ( 99 Tc m -sestamibi) and rest ( 201 Tl) gated myocardial imaging is an efficient and practical protocol for the study of myocardial perfusion and the diagnosis of ischemia

  3. Automation of TL brick dating by ADAM-1

    International Nuclear Information System (INIS)

    Cechak, T.; Gerndt, J.; Hirsl, P.; Jirousek, P.; Kubelik, M.; Musilek, L.; Kanaval, J.

    2000-01-01

    Thermoluminescence has become an established dating method for ceramics and more recently for bricks. Based on the experiences of the work carried out since the late 1970's at the Rathgen-Forschungslabor in Berlin on the dating of bricks from historic architecture, and after evaluating all commercially available and some individually built automated and semi-automated TL-readers, a specially adapted machine for the fine grain dating of bricks was constructed in an interdisciplinary research project, undertaken by a team recruited from three faculties of the Czech Technical University in Prague. The result is the automated TL-reader ADAM-1 (Automated Dating Apparatus for Monuments) for the dating of historic architecture. Both the specific adaptation of the technique and the necessary optimal automation have influenced the design of this TL-reader. The principle advantage of brick as opposed to ceramic TL-dating emerges from the possibility of being able to obtain both a large number of samples and an above average quantity of datable material from each sample. This, together with the specific physical and chemical conditions in a brick wall, allowed a rethinking of the traditional error calculation and thus lower error margins as those obtained when dating ceramic shards. The TL-reader must therefore be able to measure and evaluate automatically numerous samples. The annular sample holder of ADAM-1 has 60 sample positions, which allow the irradiation and evaluation of samples taken from two locations. The thirty samples from one sampling point are divided into subgroups, which are processed in various ways. Three samples serve for a rough estimate of the TL sensitivity of the brick material. Nine samples are used for the measurement of 'natural TL' of the material. A further nine samples are used for testing the sensitivity of the material to beta radiation. The last nine samples serve for the testing of the sensitivity to alpha radiation. To determine the

  4. Two cases of hyperparathyroidism revealed by /sup 201/Tl-chloride

    Energy Technology Data Exchange (ETDEWEB)

    Otsuka, Kokichi; Asano, Haruko; Moriyama, Shigeharu (Okayama Red Cross Hospital (Japan))

    1983-08-01

    /sup 201/Tl scintigraphy at 15 min and 120 min after intravenous injection of /sup 201/TlCl revealed a parathyroidal adenoma (1.7g) in a 49-year-old female patient with hyperthyroidism complicated by renal calculi and that (1.8g) in a 58-year-old female patient without symptoms. /sup 75/Se could be substituted by /sup 201/Tl which was useful for localizing parathyroidal adenoma in hyperparathyroidism. /sup 201/Tl scintigraphy revealed the adenoma which was not palpable. The smallest adenoma detected by it was 0.9g.

  5. Methods, qualitative and quantitative evaluations of 201Tl myocardial scintiscans

    International Nuclear Information System (INIS)

    Buell, U.; Kleinhans, E.; Klepzig, M.; Seiderer, M.; Strauer, B.E.

    1981-01-01

    Exercise 201 Tl myocardial scintiscanning is a technique used to supplement exercise electrocardiography. The procedure employed should be identical to the standard procedure of electrocardiography. If the coronary disease has already been established by coronary angiography and kineventriculography, 201 Tl examinations should be carried out before surgery in order to determine the ''regional functional reserve''. Visual evaluations of the 201 Tl scintiscans should be supplemented by quantification methods. Quantification is also required between 201 Tl examination and surgery and to assure constant diagnostic accuracy in case of examination by different examiners. (orig./MG) [de

  6. Electronic structure of TlBa2CaCu2O7-δ

    Science.gov (United States)

    Vasquez, R. P.; Novikov, D. L.; Freeman, A. J.; Siegal, M. P.

    1997-06-01

    The core levels of TlBa2CaCu2O7-δ (Tl-1212) epitaxial films have been measured with x-ray photoelectron spectroscopy (XPS). The valence electronic structure has been determined using the full-potential linear muffin-tin-orbital band-structure method and measured with XPS. The calculations show that a van Hove singularity (VHS) lies above the Fermi level (EF) for the stoichiometric compound (δ=0), while for 50% oxygen vacancies in the Tl-O layer (δ=0.5) EF is in close proximity to the VHS. Samples annealed in nitrogen (to reduce the hole overdoping by the removal of oxygen) exhibit higher core-level binding energies and a higher Tc, consistent with a shift of EF closer to the VHS. Comparisons are made to the core levels and valence bands of Tl2Ba2CaCu2O8+δ (Tl-2212) and HgBa2CaCu2O6+δ (Hg-1212). The similarity of the Cu 2p3/2 spectra for Tl-1212 and Tl-2212 indicates that the number of Tl-O layers has little effect on the Cu-O bonding. However, the Tl-1212 and Hg-1212 Cu 2p3/2 signals exhibit differences which suggest that the replacement of Tl3+ with Hg2+ results in a decrease in the O 2p-->Cu 3d charge-transfer energy and differences in the probabilities of planar vs apical oxygen charge transfer and/or Zhang-Rice singlet-state formation. Differences between the Tl-1212 and the Tl-2212 and Hg-1212 measured valence bands are consistent with the calculated Cu 3d and (Tl,Hg) 6s/5d partial densities of states.

  7. Electronic structure of TlBa2CaCu2O7-δ

    International Nuclear Information System (INIS)

    Vasquez, R.P.; Novikov, D.L.; Freeman, A.J.; Siegal, M.P.

    1997-01-01

    The core levels of TlBa 2 CaCu 2 O 7-δ (Tl-1212) epitaxial films have been measured with x-ray photoelectron spectroscopy (XPS). The valence electronic structure has been determined using the full-potential linear muffin-tin-orbital band-structure method and measured with XPS. The calculations show that a van Hove singularity (VHS) lies above the Fermi level (E F ) for the stoichiometric compound (δ=0), while for 50% oxygen vacancies in the Tl-O layer (δ=0.5) E F is in close proximity to the VHS. Samples annealed in nitrogen (to reduce the hole overdoping by the removal of oxygen) exhibit higher core-level binding energies and a higher T c , consistent with a shift of E F closer to the VHS. Comparisons are made to the core levels and valence bands of Tl 2 Ba 2 CaCu 2 O 8+δ (Tl-2212) and HgBa 2 CaCu 2 O 6+δ (Hg-1212). The similarity of the Cu 2p 3/2 spectra for Tl-1212 and Tl-2212 indicates that the number of Tl-O layers has little effect on the Cu-O bonding. However, the Tl-1212 and Hg-1212 Cu 2p 3/2 signals exhibit differences which suggest that the replacement of Tl 3+ with Hg 2+ results in a decrease in the O 2p→Cu 3d charge-transfer energy and differences in the probabilities of planar vs apical oxygen charge transfer and/or Zhang-Rice singlet-state formation. Differences between the Tl-1212 and the Tl-2212 and Hg-1212 measured valence bands are consistent with the calculated Cu 3d and (Tl,Hg) 6s/5d partial densities of states. copyright 1997 The American Physical Society

  8. Performance of Linear and Nonlinear Two-Leaf Light Use Efficiency Models at Different Temporal Scales

    Directory of Open Access Journals (Sweden)

    Xiaocui Wu

    2015-02-01

    Full Text Available The reliable simulation of gross primary productivity (GPP at various spatial and temporal scales is of significance to quantifying the net exchange of carbon between terrestrial ecosystems and the atmosphere. This study aimed to verify the ability of a nonlinear two-leaf model (TL-LUEn, a linear two-leaf model (TL-LUE, and a big-leaf light use efficiency model (MOD17 to simulate GPP at half-hourly, daily and 8-day scales using GPP derived from 58 eddy-covariance flux sites in Asia, Europe and North America as benchmarks. Model evaluation showed that the overall performance of TL-LUEn was slightly but not significantly better than TL-LUE at half-hourly and daily scale, while the overall performance of both TL-LUEn and TL-LUE were significantly better (p < 0.0001 than MOD17 at the two temporal scales. The improvement of TL-LUEn over TL-LUE was relatively small in comparison with the improvement of TL-LUE over MOD17. However, the differences between TL-LUEn and MOD17, and TL-LUE and MOD17 became less distinct at the 8-day scale. As for different vegetation types, TL-LUEn and TL-LUE performed better than MOD17 for all vegetation types except crops at the half-hourly scale. At the daily and 8-day scales, both TL-LUEn and TL-LUE outperformed MOD17 for forests. However, TL-LUEn had a mixed performance for the three non-forest types while TL-LUE outperformed MOD17 slightly for all these non-forest types at daily and 8-day scales. The better performance of TL-LUEn and TL-LUE for forests was mainly achieved by the correction of the underestimation/overestimation of GPP simulated by MOD17 under low/high solar radiation and sky clearness conditions. TL-LUEn is more applicable at individual sites at the half-hourly scale while TL-LUE could be regionally used at half-hourly, daily and 8-day scales. MOD17 is also an applicable option regionally at the 8-day scale.

  9. Value of planar 201Tl imaging in risk stratification of patients recovering from acute myocardial infarction

    International Nuclear Information System (INIS)

    Gibson, R.S.; Watson, D.D.

    1991-01-01

    Although exercise ECG testing has been shown to have important prognostic value after acute myocardial infarction, exercise 201Tl scintigraphy offers several potential advantages, including: (1) increased sensitivity for detecting residual myocardial ischemia; (2) the ability to localize ischemia to a specific area or areas subtended by a specific coronary artery; (3) the ability to identify exercise-induced left ventricular dysfunction, which is manifested by increased lung uptake or transient left ventricular dilation; and (4) more reliable risk stratification of individual patients. The more optimal prognostic efficiency of 201Tl scintigraphy partially results from the fact that the error rate in falsely classifying patients as low risk is significantly smaller with 201Tl scintigraphy than with stress ECG. Because of these substantial advantages, there seems to be adequate rationale for recommending exercise perfusion imaging rather than exercise ECG alone as the preferred method for evaluating mortality and morbidity risks after acute myocardial infarction

  10. A Call for Expanding Inclusive Student Engagement in SoTL

    Directory of Open Access Journals (Sweden)

    Peter Felten

    2013-09-01

    of student-faculty partnerships focused on inquiry into teaching and learning. However, some students tend to be privileged in SoTL initiatives while others are discouraged, implicitly or explicitly, from engaging in this work. In this paper, we consider why certain students tend to be excluded from SoTL, summarize the possible developmental gains made by students and faculty when diverse student voices are included, and highlight strategies for generating a more inclusive SoTL. We call for expanding student engagement in SoTL by encouraging a diversity of student voices to engage in co-inquiry with faculty. Inclusive engagement has tremendous potential to enhance student and faculty learning, to deepen SoTL initiatives, and to help redress the exclusionary practices that too often occur in higher education.

  11. Assessment of FIV-C infection of cats as a function of treatment with the protease inhibitor, TL-3

    Directory of Open Access Journals (Sweden)

    de Rozières Sohela

    2004-11-01

    Full Text Available Abstract Background The protease inhibitor, TL-3, demonstrated broad efficacy in vitro against FIV, HIV and SIV (simian immunodeficiency virus, and exhibited very strong protective effects on early neurologic alterations in the CNS of FIV-PPR infected cats. In this study, we analyzed TL-3 efficacy using a highly pathogenic FIV-C isolate, which causes a severe acute phase immunodeficiency syndrome, with high early mortality rates. Results Twenty cats were infected with uncloned FIV-C and half were treated with TL-3 while the other half were left untreated. Two uninfected cats were used as controls. The general health and the immunological and virological status of the animals was monitored for eight weeks following infection. All infected animals became viremic independent of TL-3 treatment and seven of 20 FIV-C infected animals developed severe immunodepletive disease in conjunction with significantly (p ≤ 0.05 higher viral RNA loads as compared to asymptomatic animals. A marked and progressive increase in CD8+ T lymphocytes in animals surviving acute phase infection was noted, which was not evident in symptomatic animals (p ≤ 0.05. Average viral loads were lower in TL-3 treated animals and of the 6 animals requiring euthanasia, four were from the untreated cohort. At eight weeks post infection, half of the TL-3 treated animals and only one of six untreated animals had viral loads below detection limits. Analysis of protease genes in TL-3 treated animals with higher than average viral loads revealed sequence variations relative to wild type protease. In particular, one mutant, D105G, imparted 5-fold resistance against TL-3 relative to wild type protease. Conclusions The findings indicate that the protease inhibitor, TL-3, when administered orally as a monotherapy, did not prevent viremia in cats infected with high dose FIV-C. However, the modest lowering of viral loads with TL-3 treatment, the greater survival rate in symptomatic animals of

  12. Conceptualizing and Communicating SoTL: A Framework for the Field

    Directory of Open Access Journals (Sweden)

    Janice Miller-Young

    2015-09-01

    Full Text Available The emerging field of SoTL is an inherently interdisciplinary endeavor which requires embracing a diverse range of research methods and disciplinary differences in world views. This diversity has caused a lack of coherence in its conceptualization and communication, which can be confusing for new scholars. Ongoing debates in the community concern the use of theory and methodology, as well as definitional questions of what constitutes SoTL and the nature of its purpose. This article offers a framework for conceptualizing the field which attempts to broadly delineate the available learning theories underlying and methodologies appropriate to studying teaching and learning, while intending to be hospitable to a broad range of diverse disciplines. Further, the framework illustrates the tacit links between learning theories and methodologies, serving as a guide to potential approaches to SoTL work. The framework is illustrated with example SoTL studies. It is hoped that the framework will help ground future SoTL investigations in appropriate theories and methodologies, and build interdisciplinary communication and understanding in the “trading zone” that is SoTL.

  13. Significance of Tl-201 redistribution on infarcted region assessed by coronary sinus flow and lactate metabolism

    International Nuclear Information System (INIS)

    Mori, Takao; Yamabe, Hiroshi; Suda, Kenichirou; Ohnishi, Masataka; Shiotani, Hideyuki; Kurimoto, Yasuyuki; Kobayashi, Katsuya; Maeda, Kazumi; Fukuzaki, Hisashi

    1987-01-01

    To clarify the significance of Tl-201 redistribution on infarcted regions, coronary sinus and great cardiac vein flow response and lactate metabolism assessed by Webster catheter on 14 infarcted regions after dipyridamole administration were compared with Tl-201 redistribution phenomenon. The regional coronary flow response and lactate extraction ratio in 11 regions with Tl-201 redistribution were lower than those in 3 regions without Tl-201 redistribution. Only 5 regions in 11 with Tl-201 redistribution showed lactate production. The coronary flow response in 5 regions with lactate production was not different from those in 6 without lactate production (1.16 ± 0.89 vs. 1.47 ± 0.67; n.s.). The degree of Tl-201 redistribution assessed by relative activity was not different between regions with and without lactate production. The left ventricular end-diastolic pressure elevated in 5 regions with lactate production (17.8 ± 5.4 mmHg to 29.6 ± 4.9 mmHg; p < 0.05), but didn't in 6 regions without lactate production. Five regions with lactate production contained 4 hypokinetic regions, on the other hand 6 regions without lactate production contained only 3 hypokinetic regions. In conclusion, Tl-201 redistribution on infarcted region revealed not only ischemia but also decreased coronary flow response without lactate production and/or left ventricular dysfunction. (author)

  14. Experimental studies on radiation damages of CsI(Tl) crystals

    International Nuclear Information System (INIS)

    He Jingtang; Mao Yufang; Dong Xiaoli; Chen Duanbao; Li Zuhao

    1997-01-01

    The results of experimental studies on radiation damage of CsI(Tl) crystal were reported. There are radiation damage effects on CsI(Tl) crystal. Experimental studies on recovery of damaged CsI(Tl) crystals were made. It seems that after heating at 200 degree C for 4 hours, the damaged crystals could be recovered completely

  15. Very low background gamma spectrometer mounted in anti-Compton with NaI(Tl) for the study of glaciers and sediment samples; Spectrometrie gamma a tres bas niveau avec anti-Compton NaI(Tl), pour l`etude des glaciers et des sediments

    Energy Technology Data Exchange (ETDEWEB)

    Pinglot, J.F.; Pourchet, M. [Centre National de la Recherche Scientifique (CNRS), 38 - Grenoble (France). Lab. de Glaciologie

    1994-05-01

    The determination of natural and artificial radioactivities of snow (glaciers, polar ice-caps) or sediment samples (lakes, oceans), takes great benefit with the use of the superior resolution of high purity germanium detector, N type, in a broad energy range( 10 keV up to 1.6 MeV). This detector (relative efficiency: 20%), very low background specified, is mounted in anti-Compton with a 9`x 8` NaI(Tl) scintillator, also with low background. International standards, used with a quantitative software allows the determination of the efficiency curve and the isotopes identification and specific activity. The anti-Compton suppressed spectrometer exhibits a decrease of the background by a factor of ten, without any change in efficiencies. Applications of this spectrometer deal with samples from lake Titicaca and a glacier from Spitsbergen. (authors). 6 figs., 7 refs.

  16. Prediction of Phase Separation of Immiscible Ga-Tl Alloys

    Science.gov (United States)

    Kim, Yunkyum; Kim, Han Gyeol; Kang, Youn-Bae; Kaptay, George; Lee, Joonho

    2017-06-01

    Phase separation temperature of Ga-Tl liquid alloys was investigated using the constrained drop method. With this method, density and surface tension were investigated together. Despite strong repulsive interactions, molar volume showed ideal mixing behavior, whereas surface tension of the alloy was close to that of pure Tl due to preferential adsorption of Tl. Phase separation temperatures and surface tension values obtained with this method were close to the theoretically calculated values using three different thermodynamic models.

  17. X-ray photoemission studies of Zn doped Cu1-xTl xBa2Ca2Cu 3-yZn yO10-δ (y = 0, 2.65) superconductors

    International Nuclear Information System (INIS)

    Khan, Nawazish A.; Mumtaz, M.; Ahadian, M.M.; Iraji-zad, Azam

    2007-01-01

    The X-ray photoemission (XPS) measurements of Cu 1-x Tl x Ba 2 Ca 2 Cu 3-y Zn y O 10-δ (y = 0, 2.65) superconductors have been performed and compared. These studies revealed that the charge state of thallium in the Cu 0.5 Tl 0.5 Ba 2 O 4-δ charge reservoir layer in Zn doped samples is Tl 1+ , while it is a mix of Tl 1+ and Tl 2+ in Zn free samples. The binding energy of Ba atoms in the Zn doped samples is shifted to higher energy, which when considered along with the presence of Tl 1+ suggested that it more efficiently directed the carriers to ZnO 2 and CuO 2 planes. The evidence of improved inter-plane coupling witnessed in X-ray diffraction is also confirmed by XPS measurements of Ca atoms in the Zn doped samples. The shift of the valance band spectrum in these Zn doped samples to higher energies suggested that the electrons at the top edge of the valance band were tied to a higher binding energy (relative to samples without Zn doping), which most likely resulted in a much lower energy state of the system in the superconducting state. The stronger superconducting state arising out of these effects is witnessed in the form of increased T c (R 0), J c and the extent of diamagnetism in the final compound

  18. Stability of Tl-Ba-Ca-Cu-O superconducting thin films

    International Nuclear Information System (INIS)

    Siegal, M. P.; Overmyer, D. L.; Venturini, E. L.; Padilla, R. R.; Provencio, P. N.

    1999-01-01

    We report the stability of TlBa 2 CaCu 2 O 7 and Tl 2 Ba 2 CaCu 2 O 8 on LaAlO 3 (100) epitaxial thin films, under a variety of conditions. All films are stable in acetone and methanol and with repeated thermal cycling to cryogenic temperatures. Moisture, especially vapor, degrades film quality rapidly. These materials are stable to high temperatures in either N 2 or O 2 ambients. While total degradation, resulting from Tl depletion, occurs at the same temperatures for both phases, 600 degree sign C in N 2 and 700 degree sign C in O 2 , the onset of degradation occurs at somewhat lower temperatures for TlBa 2 CaCu 2 O 7 than for Tl 2 Ba 2 CaCu 2 O 8 . (c) 1999 Materials Research Society

  19. Electronic Structure of TlBa2CaCu2O(7-Delta)

    Science.gov (United States)

    Vasquez, R. P.; Novikov, D. L.; Freeman, A. J.; Siegal, M. P.

    1997-01-01

    The core levels of TlBa2CaCu2O(7-delta) (Tl-1212) epitaxial films have been measured with X-ray photoelectron spectroscopy (XPS). The valence electronic structure has been determined using the full-potential linear muffin-tin-orbital band-structure method and measured with XPS. The calculations show that a van Hove singularity (VHS) lies above the Fermi level (E(sub F)) for the stoichiometric compound (delta = 0.5), while for 50% oxygen vacancies in the Tl-O layer (delta = 0.5) E(sub F) is in close proximity to the VHS. Samples annealed in nitrogen (to reduce the hole overdoping by the removal of oxygen) exhibit higher core-level binding energies and a higher T(sub c), consistent with a shift of E(sub F) closer to the VHS. Comparisons are made to the core levels and valence bands of Tl2Ba2CaCu2O(8 + delta)(Tl-2212) and HgBa2CaCu2O)6 + delta) (Hg- 1212). The similarity of the Cu 2p(sub 3/2) spectra for Tl-1212 and Tl-2212 indicates that the number of Tl-O layers has little effect on the Cu-O bonding. However, the Tl-1212 and Hg-1212 Cu 2p(sub 3/2) signals exhibit differences which suggest that the replacement of T(sup 3+) with Hg(sup 2+) results in a decrease in the O 2p right arrow Cu 3d charge-transfer energy and differences in the probabilities of planar vs apical oxygen charge transfer and/or Zhang-Rice singlet-state formation. Differences between the Tl-1212 and the Tl-2212 and Hg-1212 measured valence bands are consistent with the calculated Cu 3d and (Tl,Hg) 6s/5d partial densities of states.

  20. TL response of citrine samples for high-dose dosimetry

    International Nuclear Information System (INIS)

    Teixeira, Maria Ines; Caldas, Linda V.E.

    2011-01-01

    The possibility of using samples of Brazilian stones as quartz, amethyst, topaz, etc. for high-dose dosimetry has been studied in recent years at IPEN, using the thermoluminescence technique (TL). In this work, the TL properties of citrine samples were studied. They were exposed to different doses of gamma radiation ( 60 Co). The natural citrine stone was extracted from a mine in Minas Gerais state, Brazil; it is a tectosilicate ranked as one of three-dimensional structure, showing clear yellow to golden brown color. The natural citrine stone is classified as quartz (SiO 2 ), and it has a lower symmetry and more compact reticulum. The citrine stone samples were powdered, and the selected grains were mixed with Teflon in the proportion 2 (Teflon):1 (Citrine). The mixture was pressed and sintered for production of Citrine -Teflon pellets of 50 mg. The TL emission curve showed two peaks at 160 deg C and 220 deg C. To remove the TL peak (160 deg C) of the sintered citrine pellet glow curves, different thermal treatments were tested during several time intervals. The TL dose-response curve between 50 Gy and 100 kGy, the reproducibility of TL response and the lower detection dose were obtained. The preliminary results show that citrine may be useful for high-dose dosimetry. (author)

  1. Magnetism and superconductivity of some Tl-Cu oxides

    Science.gov (United States)

    Datta, Timir

    1991-01-01

    Many copper oxide based Thallium compounds are now known. In comparison to the Bi-compounds, the Tl-system shows a richer diversity; i.e., High Temperature Superconductors (HTSC) can be obtained with either one or two Tl-0 layers (m = 1,2); also, the triple-digit phases are easier to synthesize. The value of d, oxygen stoichiometry, is critical to achieving superconductivity. The Tl system is robust to oxygen loss; Tl may be lost or incorporated by diffusion. A diffusion coefficient equal to 10 ms at 900 C was determined. Both ortho-rhombic and tetragonal structures are found, but HTSC behavior is indifferent to the crystal symmetry. This system has the highest T(sub c) confirmed. T(sub c) generally increases with p, the number of CuO layers, but tends to saturate at p = 3. Zero resistance was observed at temperatures as great as 125 K. Most of these HTSC's are hole type, but the Ce-doped specimens may be electronic. The magnetic aspects were studied; because in addition to defining the perfectly diamagnetic ground state as in conventional superconductors, magnetism of the copper oxides show a surprising variety. This is true of both the normal and the superconducting states. Also, due to the large phonon contribution to the specific heat at the high T(sub c) jump, electronic density of states, D(Ef), and coherence length are uncertain, and thus, are estimated from the magnetic results. Results from the Tl-system CuO, LaBaCuO,120 and the Bi-CuO compounds are discussed. The emphasis is on the role of magnetism in the Tl-CuO HTSC, but technological aspects are also pointed out.

  2. Developing SoTL through Organized Scholarship Institutes

    Directory of Open Access Journals (Sweden)

    Elizabeth Marquis

    2015-12-01

    Full Text Available The need to further integrate SoTL into college and university cultures has been discussed relatively frequently in recent teaching and learning literature. While a number of useful strategies to assist in this task have been advanced, one especially promising suggestion is the development of organized, institutionally-recognized scholarship institutes. Centres or units of this sort have been created at higher education institutions in a number of countries, but little published information currently exists about the design of these institutes or the experiences of individuals affiliated with them. To that end, the present study sought to examine the perceived benefits, challenges and design features of teaching and learning scholarship institutes at research-intensive universities worldwide. A website scan and a survey of individuals affiliated with these units were used to collect qualitative and quantitative data of relevance to the research questions. Based on the findings, and on ideas from the existing research institute and scholarship of teaching and learning literatures, a series of recommendations for individuals and campuses interested in developing effective SoTL institutes are provided.

  3. Relative efficiency of the radiothermoluminescence induced by 238Pu alpha-particles in LiF:Mg, Al2O3 and CaSO4:Dy

    International Nuclear Information System (INIS)

    Vicy, Masok.

    1978-01-01

    This work represents a comparative study of the radiothermoluminescence (R.T.L.) induced by 60 Co gamma rays and 238 Pu alpha-particles in three R.T.L. materials: lithium fluoride, alumina and dysprosium activated calcium sulphate. The T.L. glow curves induced by the two radiations are very similar. However, for the same absorbed dose, different sensitivity is seen to each form of irradiation. Measurements of the relative R.T.L. efficiency, epsilon, were made in the linear zone (dose [fr

  4. Two-equivalent electrochemical reduction of a cyano-complex [TlIII(CN)2]+ and the novel di-nuclear compound [(CN)5PtII-TlIII]0

    International Nuclear Information System (INIS)

    Dolidze, Tina D.; Khoshtariya, Dimitri E.; Behm, Martin; Lindbergh, Goeran; Glaser, Julius

    2005-01-01

    Extending our recent insights in two-electron transfer microscopic mechanisms for a Tl III /Tl I redox system [D.E. Khoshtariya, et al., Inorg. Chem. 41 (2002) 1728], the electrochemical response of glassy carbon electrode in acidified solutions of Tl III (ClO 4 ) 3 containing different concentrations of sodium cyanide has been extensively studied for the first time by use of cyclic voltammetry and the CVSIM curve simulation PC program. The complex [Tl III (CN) 2 ] + has been thoroughly identified electrochemically and shown to display a single well-defined reduction wave (which has no anodic counterpart), ascribed to the two-equivalent process yielding [Tl I (aq)] + . This behavior is similar to that of [Tl III (aq)] 3+ ion in the absence of sodium cyanide, disclosed in the previous work, and is compatible with the quasi-simultaneous yet sequential two-electron transfer pattern (with two reduction waves merged in one), implying the rate-determining first electron transfer step (resulting in the formation of a covalently interacting di-thallium complex as a metastable intermediate), and the fast second electron transfer step. Some preliminary studies of the two-equivalent reduction of directly metal-metal bonded stable compound [(CN) 5 Pt II -Tl III ] 0 has been also performed displaying two reduction waves compatible with a true sequential pattern

  5. Effects of film thickness on scintillation characteristics of columnar CsI:Tl films exposed to high gamma radiation doses

    Energy Technology Data Exchange (ETDEWEB)

    Shinde, Seema; Singh, S.G.; Sen, S.; Gadkari, S.C., E-mail: gadkari@barc.gov.in

    2016-02-21

    Oriented columnar films of Tl doped CsI (CsI:Tl) of varying thicknesses from 50 µm to 1000 µm have been deposited on silica glass substrates by a thermal evaporation technique. The SEM micrographs confirmed the columnar structure of the film while the powder X-ray diffraction pattern recorded for the films revealed a preferred orientation of the grown columns along the <200> direction. Effects of high energy gamma exposure up to 1000 Gy on luminescence properties of the films were investigated. Results of radio-luminescence, photo-luminescence and scintillation studies on the films are compared with those of a CsI:Tl single crystal with similar thickness. A possible correlation between the film thicknesses and radiation damage in films has been observed. - Highlights: • CsI:Tl films of different thicknesses deposited for γ and α detection. • Pulse-height spectra found to degrade with increasing thickness. • Radiation damage is found more in films than single crystal of comparable thickness. • Detection efficiency increases for γ while it is invariant for α beyond 50 µm.

  6. Effects of film thickness on scintillation characteristics of columnar CsI:Tl films exposed to high gamma radiation doses

    International Nuclear Information System (INIS)

    Shinde, Seema; Singh, S.G.; Sen, S.; Gadkari, S.C.

    2016-01-01

    Oriented columnar films of Tl doped CsI (CsI:Tl) of varying thicknesses from 50 µm to 1000 µm have been deposited on silica glass substrates by a thermal evaporation technique. The SEM micrographs confirmed the columnar structure of the film while the powder X-ray diffraction pattern recorded for the films revealed a preferred orientation of the grown columns along the direction. Effects of high energy gamma exposure up to 1000 Gy on luminescence properties of the films were investigated. Results of radio-luminescence, photo-luminescence and scintillation studies on the films are compared with those of a CsI:Tl single crystal with similar thickness. A possible correlation between the film thicknesses and radiation damage in films has been observed. - Highlights: • CsI:Tl films of different thicknesses deposited for γ and α detection. • Pulse-height spectra found to degrade with increasing thickness. • Radiation damage is found more in films than single crystal of comparable thickness. • Detection efficiency increases for γ while it is invariant for α beyond 50 µm.

  7. Left ventricular ejection fraction determined by gated Tl-201 perfusion SPECT and quantitative software

    International Nuclear Information System (INIS)

    Hyun, In Young; Kim, Sung Eun; Seo, Jeong Kee; Hong, Eui Soo; Kwan, Jun; Park, Keum Soo; Lee, Woo Hyung

    2000-01-01

    We compared estimates of ejection fraction (EF) determined by gated Tl-201 perfusion SPECT (g-Tl-SPECT) with those by gated blood pool (GBP) scan. Eighteen subjects underwent g-Tl-SPECT and GBP scan. After reconstruction of g-Tl-SPECT, we measured EF with Cedars software. The comparison of the EF with g-Tl-SPECT and GBP scan was assessed by correlation analysis and Bland Altman plot. The estimates of EF were significantly different (p<0.05) with g-Tl-SPECT (40%±14%) and GBP scan (43%±14%). There was an excellent correlation of EF between g-Tl-SPECT and GBP scan (r=3D0.94, p<0.001). The mean difference of EF between GBP scan and g-Tl-SPECT was +3.2%. Ninety-five percent limits of agreement were ±9.8%. EF between g-Tl-SPECT and GBP scan were in poor agreement. The estimates of EF by g-Tl-SPECT was well correlated with those by GBP scan. However, EF of g-Tl-SPECT doesn't agree with EF of GBP scan. EF of g-Tl-SPECT can't be used interchangeably with EF of GBP scan.=20

  8. TL and OSL studies of carbon doped magnesium aluminate (MgAl2O4:C)

    Science.gov (United States)

    Raj, Sanu S.; Mishra, D. R.; Soni, Anuj; Grover, V.; Polymeris, G. S.; Muthe, K. P.; Jha, S. K.; Tyagi, A. K.

    2016-10-01

    The MgAl2O4:C has been synthesized by using two different methods by electron gun and vacuum assisted melting of MgAl2O4 in presence of graphite. The MgAl2O4:C phosphor thus developed by these two different methods have similar types of the TL/OSL defects with multiple overlapping TL glow peaks from 100 °C to 400 °C. The Computerized Curve De-convolution Analysis (CCDA) has been used to measure TL parameters such as thermal trap depth, frequency factor and order of kinetic associated with charge transfer process in TL phenomenon. The investigated TL/OSL results show that these two methods of incorporating carbon in MgAl2O4 have generated closely resemble the defects of similar types in MgAl2O4:C lattice. However, the MgAl2O4:C synthesized by electron gun shows relatively larger concentration of the TL/OSL defects as compared to MgAl2O4:C synthesized using vacuum assisted melting method. The photo-ionization cross-section (PIC) associated with fastest OSL component of MgAl2O4: C is found to be ∼ 0.5 times than that of fastest OSL component of commercially available dosimetric grade α-Al2O3:C. The MgAl2O4:C thus developed shows good dynamic OSL dose linearity from few mGy to 1 Gy. This work reveals that MgAl2O4:C could be developed as potential tissue equivalent OSL / TL material.

  9. Tl and OSL on diopside crystal

    International Nuclear Information System (INIS)

    Cano, N.F.; Watanabe, S.; Mittani, J.C.R.; Yukihara, E.G.

    2006-01-01

    The diopside with chemical composition CaMgSi 2 O 6 is part of an important solid solution series of the pyroxene group. The mineral is commonly found in meteorites and it is an important rock forming mineral of medium and high grade metamorphic rocks which are rich in calcium. In the bibliography it is possible to found several studies on electron spin resonance (ESR), reflectance, etc. but not on thermoluminescence (TL) or optically stimulated luminescence (OSL). In the present work we studied diopside TL and OSL behaviour on natural and natural irradiated samples. The sample used in our study is a white coloured diopside provided by Mineracao Sao Judas located in Sao Paulo, Brazil. The X-Ray Fluorescence technique has shown high concentrations of SiO 2 (55.81 % mol), CaO (23.47 % mol), MgO (18.03 % mol), Al 2 O 3 (1.56 % mol), Fe 2 O 3 (0.53 % mol), K 2 O (0.44 % mol), TiO 2 (0.065 % mol), P 2 O 5 (0.026 % mol), and MnO (0.013 % mol). TL measurements on natural samples show four TL peaks at 160, 260, 360, and 450 C. After beta-irradiation an increment mainly in the low temperature peaks is observed. As for OSL measurements, low OSL signal was observed on natural samples using blue light stimulation and UV detection. The intensity of the signal was observed to increase with the irradiation dose. (Author)

  10. TL and OSL properties of Mn2+-doped MgGa2O4 phosphor

    Science.gov (United States)

    Luchechko, A.; Zhydachevskyy, Ya; Maraba, D.; Bulur, E.; Ubizskii, S.; Kravets, O.

    2018-04-01

    The oxide MgGa2O4 spinel ceramics doped with Mn2+ ions was synthesized by a solid-state reaction at 1200 °C in air. The activator concentration was equal 0.05 mol% of MnO. Phase purity of the synthesized samples was analyzed by X-ray diffraction technique. This spinel ceramics show efficient green emission in the range from 470 to 550 nm with a maximum at about 505 nm under UV or X-ray excitations, which is due to Mn2+ ions. MgGa2O4: Mn2+ exhibits intense thermoluminescence (TL) and optically stimulated luminescence (OSL) after influence of ionizing radiation. Are complex nature of the TL glow curves is associated with a significant number of structural defects that are responsible for the formation of shallow and deep electron traps. In this work, time-resolved OSL characteristics of the samples exposed to beta particles are reported for the first time. A light from green LED was used for optical stimulation. Obtained TL and OSL results suggest MgGa2O4:Mn2+ as perspective material for further research and possible application in radiation dosimetry.

  11. Auto-regenerative TL dating with zircon inclusions from fired materials

    International Nuclear Information System (INIS)

    Templer, R.H.; Smith, B.W.

    1988-01-01

    In this paper it is shown that it is possible to date fired material using zircon inclusions. The effects of zoning and anomalous fading are overcome using an auto-regenerative dating procedure. The high radioactivity of the grains gives a measurable self-induced TL (thermoluminescence) signal within a few months. Comparison of this ''auto-regenerated'' TL with the natural TL (which has accumulated since the firing) yields the age of the material. A sensitive TL reader capable of recording the auto-regenerated signal after 6 months is also described, and the results of age determinations on a number of known age samples are presented. (author)

  12. Supralinear response and efficiency of LiF:Mg,Ti to 0.7, 1.5 and 3 MeV protons

    International Nuclear Information System (INIS)

    Gamboa-deBuen, I.; Aviles, P.; Rodriguez-Villafuerte, M.; Buenfil, A.E.; Ruiz-Trejo, C.; Brandan, M.E.

    2001-01-01

    The thermoluminescent (TL) response, supralinearity function, and relative efficiency with respect to 60 Co γ-rays, of TLD-100 exposed to 0.7, 1.5 and 3 MeV protons have been measured. The TL response of the glow curve peaks using two different deconvolutions, separating in either 7 (3-9) or 9 peaks (3-10 and peaks 6a and 6b), was investigated. Results for the supralinearity function of peaks 5 and 7-9 and the relative response of peaks 5 and 7 are insensitive to the chosen deconvolution scheme. At all energies we observe that peak 5 is slightly supralinear and that supralinearity increases as a function of the peak temperature. The relative efficiencies, measured for the total TL signal (area under the glow curve) and peaks 5 and 7, decrease with the proton energy having values of 0.33, 0.46 and 0.70 (total TL signal), 0.22, 0.32 and 0.53 (peak 5) and 1.4, 2.6 and 3.6 (peak 7) at 0.7, 1.5 and 3 MeV, respectively. These data agree with the systematics reported in the literature. The measurements of the supralinearity function are compared with Monte Carlo track interaction model calculations. The analysis suggests that the model ion track effective radius and the saturation radius are independent of the incident ion energy

  13. Progress and problems with automated TL dating

    International Nuclear Information System (INIS)

    McKerrell, H.; Mejdahl, V.

    1981-01-01

    A number of basic problems connected with the measurement of beta and gamma dose-rates are discussed, and the possibility of using low-temperature peaks in quartz and feldspar for dose-rate measurements is examined. Preliminary results of TL measurements on individual grains of quartz and feldspar are presented. A TL dating method based on the difference in the archaeological dose received by potassium feldspar and quartz grains is proposed. (author)

  14. The Tl{sub 2}S–PbS–SiS{sub 2} system and the crystal and electronic structure of quaternary chalcogenide Tl{sub 2}PbSiS{sub 4}

    Energy Technology Data Exchange (ETDEWEB)

    Mozolyuk, M.Y.; Piskach, L.V. [Department of Inorganic and Physical Chemistry, Lesya Ukrainka Eastern European National University, 13 Voli Avenue, 43025, Lutsk (Ukraine); Fedorchuk, A.O. [Department of Inorganic and Organic Chemistry, Lviv National University of Veterinary Medicine and Biotechnologies, 50 Pekarska Street, 79010, Lviv (Ukraine); Olekseyuk, I.D.; Parasyuk, O.V. [Department of Inorganic and Physical Chemistry, Lesya Ukrainka Eastern European National University, 13 Voli Avenue, 43025, Lutsk (Ukraine); Khyzhun, O.Y., E-mail: khyzhun@ipms.kiev.ua [Frantsevych Institute for Problems of Materials Science, National Academy of Sciences of Ukraine, 3 Krzhyzhanivsky Street, 03142, Kyiv (Ukraine)

    2017-07-01

    Chalcogenides of the quasi-ternary system Tl{sub 2}S–PbS–SiS{sub 2} were synthesized in the evacuated silica ampoules by the melting and annealing technique. Phase equilibria in the system was investigated by XRD method. Isothermal section of the system was studied, and two intermediate quaternary phases were discovered to exist (Tl{sub 2}PbSiS{sub 4}, ∼Tl{sub 2}PbSi{sub 3}S{sub 8}). The quasi-binary section Tl{sub 2}SiS{sub 3}–PbS was investigated by DTA. Its phase diagram was constructed, and it was established that the equimolar compound melts incongruently at 818 K. The crystal structure of the quaternary compound Tl{sub 2}PbSiS{sub 4} was determined by X-ray powder diffraction. It crystallizes in the monoclinic space group P2{sub 1}/a with the unit-cell parameters a = 8.8141(4), b = 9.0150(5), c = 10.4383(5) Å, and β = 94.490(4)° (Tl{sub 2}PbGeS{sub 4} structure type). Reliability factors calculated in the isotropic approximation were found to be R{sub I} = 0.0564 and R{sub P} = 0.1070. The Tl{sub 2}PbSiS{sub 4} single crystal was tested with X-ray photoelectron spectroscopy. In particular, the XPS core-level and valence-band spectra were recorded for pristine and Ar{sup +}-ion bombarded surfaces of Tl{sub 2}PbSiS{sub 4}. The Tl{sub 2}PbSiS{sub 4} single crystal was found to be rather stable with respect to Ar{sup +}-ion irradiation. We have also measured the X-ray emission band depicting the energy distribution of mainly the S 3p states and compared it on a common energy scale with the XPS valence-band spectrum of the Tl{sub 2}PbSiS{sub 4} crystal. The above comparison indicates that the S 3p states contribute substantively in the upper portion of the valence band of Tl{sub 2}PbSiS{sub 4}, with their significant contributions in other portions of the valence-band region. - Highlights: • Chalcogenides of the quasi-ternary system Tl{sub 2}S–PbS–SiS{sub 2} were synthesized. • Two intermediate quaternary phases were discovered to exist (Tl

  15. Contributions to a systematic examination of deformed transition nuclei by the study of the decay of 188Tl and 190Tl

    International Nuclear Information System (INIS)

    Waetzig, W.

    1980-01-01

    Using the reaction 197 Au( 3 He,xn) Tl the decay of the nuclides 188 Tl and 190 Tl to 188 Hg (Tsub(1/2) = 70s) respectively to 190 Hg(Tsub(1/2) = 3.0 min) was studied at the mass separator ISOCELE of the Orsay-synchrocyclotron by gamma, conversion electron, gamma-gamma coincidence, and electron-gamma coincidence spectroscopy. The level schemes of 188 Hg and 190 Hg could be remarkably extended in comparison with earlier works. By a statistical analysis of the nuclear level density the nuclear temperature was calculated as a measure for the number of excitation modes of these nuclei. (orig./HSI) [de

  16. Performance of novel materials for radiation detection: Tl3AsSe3, TlGaSe2, and Tl4HgI6

    International Nuclear Information System (INIS)

    Kahler, D.; Singh, N.B.; Knuteson, D.J.; Wagner, B.; Berghmans, A.; McLaughlin, S.; King, M.; Schwartz, K.; Suhre, D.; Gotlieb, M.

    2011-01-01

    In this paper we report on the electrical characteristics of three novel ternary compounds, Tl 3 AsSe 3 (TAS), TlGaSe 2 (TGS), and Tl 4 HgI 6 (THI), pertaining to their use as radiation detectors. The details for growth and material characterization are not presented. A semiconductor based gamma ray detector requires a material with high Z, high density, high resistivity, appropriate bandgap (1.5-2 eV), low energy/electron-hole pair, and a high μτ product. CZT is currently the best semiconductor material for room temperature gamma ray spectroscopy; however, it is extremely difficult to produce large volumes of detector grade material, making it expensive and in limited supply. DNDO/DHS began searching for other materials that might perform as well as CZT but be easier to grow and in the end lower the cost. For this purpose, we investigated the above three materials as possible replacements for CZT as gamma ray detectors. The bulk resistivity, I-V curves, X-ray response, and gamma ray response measurements for doped and undoped crystals are presented and discussed. TAS shows good X-ray and gamma ray response, but has poor resistivity, which results in large dark current and poor spectral response. TGS has good resistivity, but shows poor X-ray and gamma ray response. THI has excellent resistivity, shows some X-ray and gamma ray response, and has great potential as a gamma ray detector.

  17. Leg 201Tl-SPECT in chronic exertional compartment syndrome

    International Nuclear Information System (INIS)

    Elkadri, N.; Slim, I.; Blondet, C.; Choquet, Ph.; Constantinesco, A.; Lecocq, J.

    2004-01-01

    Leg 201 Tl-SPECT in chronic exertional compartment syndrome Background: The chronic exertional compartment syndrome is one of the most frequent origins regarding leg pain due to sport training. The diagnosis can be established by invasive compartment pressure measurement. The aim of this study is to evaluate the role that could have 201 Tl-SPECT for patients with suspicion of compartment syndrome. Patients and methods: 51 leg 201 Tl-SPECT exams were performed (exercise - and rest without reinjection) in 49 patients; 28 had compartment syndrome confirmed by pressure measurement. About 100 MBq of 201 Tl were injected during exercise, when pain appeared or at least after 25 minutes exercise. We studied mean percentages of level uptake for each compartment, referred to the maximal uptake of both legs. Results: 47 compartments were concerned by compartment syndrome and 361 compartments were not. Scintigraphic patterns in compartments are reversible ischaemia (45%), uptake stability (36%) or reverse redistribution (19%); these patterns are not linked to compartment syndrome. However, there is a significant difference of rest 201 Tl level uptake between compartments with and without compartment syndrome and a significant correlation between muscular pressure measurement and rest level uptake. Conclusion: 201 Tl-SPECT shows that only ischaemia does not explain compartment syndrome. Moreover, it allows to predict pressure variation during exercise but it does not offer any interest in order to select patients for muscular invasive pressure measurement. (author)

  18. Results from an investigation of the physical origins of nonproportionality in CsI(Tl)

    Science.gov (United States)

    Asztalos, S.; Hennig, W.; Warburton, W. K.

    2011-10-01

    The relative scintillation response per energy deposited by Compton electrons, or nonproportionality, has traditionally been considered an intrinsic scintillator property. However, such an interpretation is inconsistent with recent results that show nonproportionality to depend on external factors such as shaping time, temperature and supplier. Apparently, at least some of the overall nonproportionality has an extrinsic origin. In this work we describe the results from a suite of measurements designed to test the hypothesis that nonproportionality in CsI(Tl) material has an extrinsic component that correlates with impurity levels. Our choice of material was motivated by the excellent energy resolution observed in one bulk crystal (6.4%)—a marked departure from that measured with conventional CsI(Tl) stock (8-8.5%). Six bulk CsI(Tl) crystals were procured and diced into 44 wafers. Using X-ray fluorescence techniques no conclusive evidence for impurities was found in any of the wafers at the 1-50 ppm level. One crystal exhibited a distinct correlation among energy resolution, decay lifetimes, nonproportionality and a very low level of Tl doping.

  19. Results from an investigation of the physical origins of nonproportionality in CsI(Tl)

    International Nuclear Information System (INIS)

    Asztalos, S.; Hennig, W.; Warburton, W.K.

    2011-01-01

    The relative scintillation response per energy deposited by Compton electrons, or nonproportionality, has traditionally been considered an intrinsic scintillator property. However, such an interpretation is inconsistent with recent results that show nonproportionality to depend on external factors such as shaping time, temperature and supplier. Apparently, at least some of the overall nonproportionality has an extrinsic origin. In this work we describe the results from a suite of measurements designed to test the hypothesis that nonproportionality in CsI(Tl) material has an extrinsic component that correlates with impurity levels. Our choice of material was motivated by the excellent energy resolution observed in one bulk crystal (6.4%)-a marked departure from that measured with conventional CsI(Tl) stock (8-8.5%). Six bulk CsI(Tl) crystals were procured and diced into 44 wafers. Using X-ray fluorescence techniques no conclusive evidence for impurities was found in any of the wafers at the 1-50 ppm level. One crystal exhibited a distinct correlation among energy resolution, decay lifetimes, nonproportionality and a very low level of Tl doping.

  20. Accidental and retrospective dosimetry using TL method

    International Nuclear Information System (INIS)

    Mesterházy, D.; Osvay, M.; Kovács, A.; Kelemen, A.

    2012-01-01

    Retrospective dosimetry is one of the most important tools of accidental dosimetry for dose estimation when dose measurement was not planned. In the affected area many objects can be applied as natural dosimeters. The paper discusses our recent investigations on various electronic components and common salt (NaCl) having useful thermoluminescence (TL) properties. Among materials investigated the electronic components of cell phones seem promising for retrospective dosimetry purposes, having high TL responses, proper glow curve peaks and the intensity of TL peaks vs. gamma dose received provided nearly linear response in the dose range of 10 mGy–1.5 Gy. - Highlights: ► Electronic components and common salt were investigated for accidental and retrospective dosimetry. ► SMD resistors seem promising for retrospective dosimetry purposes. ► Table salt can be used effectively for accidental dosimetry purposes, as well.

  1. Stability of Tl-Ba-Ca-Cu-O superconducting thin films

    Energy Technology Data Exchange (ETDEWEB)

    Siegal, M. P. [Sandia National Laboratories, Albuquerque, New Mexico 87185-1421 (United States); Overmyer, D. L. [Sandia National Laboratories, Albuquerque, New Mexico 87185-1421 (United States); Venturini, E. L. [Sandia National Laboratories, Albuquerque, New Mexico 87185-1421 (United States); Padilla, R. R. [Sandia National Laboratories, Albuquerque, New Mexico 87185-1421 (United States); Provencio, P. N. [Sandia National Laboratories, Albuquerque, New Mexico 87185-1421 (United States)

    1999-12-01

    We report the stability of TlBa{sub 2}CaCu{sub 2}O{sub 7} and Tl{sub 2}Ba{sub 2}CaCu{sub 2}O{sub 8} on LaAlO{sub 3}(100) epitaxial thin films, under a variety of conditions. All films are stable in acetone and methanol and with repeated thermal cycling to cryogenic temperatures. Moisture, especially vapor, degrades film quality rapidly. These materials are stable to high temperatures in either N{sub 2} or O{sub 2} ambients. While total degradation, resulting from Tl depletion, occurs at the same temperatures for both phases, 600 degree sign C in N{sub 2} and 700 degree sign C in O{sub 2}, the onset of degradation occurs at somewhat lower temperatures for TlBa{sub 2}CaCu{sub 2}O{sub 7} than for Tl{sub 2}Ba{sub 2}CaCu{sub 2}O{sub 8}. (c) 1999 Materials Research Society.

  2. High current Tl-203, Rh-103 targets preparation for cyclotron production of Tl-201 and Pd-103 radionuclides

    International Nuclear Information System (INIS)

    Arzumanov, A.; Berger, V.; Borissenko, A.; Gorodisskaya, N.; Ilmatov, I.; Knyazev, A.; Koptev, V.; Lyssukhin, S.; Platov, A.; Sychikov, G.; Zheltov, D.

    2004-01-01

    The objectives of the present work are to increase thermal stability of cyclotron targets for production of Tl-201 isotope, increase Tl-203 regeneration rate at radiochemical reprocessing of the targets and develop production technology for radiochemical sources based on Rd-103 isotope. Electrochemical coating of copper substrate with Tl increased the beam current at target irradiation from 100 μA to 125 μA. Further increase of the beam current results in sharp decrease of target stability time at irradiation to 15 min at beam current 150 μA. Thermal calculations and tests at the electron-beam stand predict satisfactory stability at such currents. The discrepancy with the irradiation results has not been explained. More accurate specification of regimes for Tl-203 electrochemical recovery from irradiated targets and better matching of the electrolyte composition made it possible to increase the recovery rate up to 99.5%. Before the present Project, the INP had no experience in production of radioactive sources based on Pd-103. Thermo-diffusion extraction of Pd-103 from irradiated rhodium foil has been chosen as a technology-defining method. The process assures good extraction rate and high purity of extracted isotope. Production of Pd-103 sources based on this technology is much simpler compared to the same based on electrochemical processes. (author)

  3. Photo-TL in CaSO4:Dy: high exposure dosimetry

    International Nuclear Information System (INIS)

    Caldas, L.V.E.; Mayhugh, M.R.

    1974-01-01

    CaSO 4 :Dy exposed to 10 3 to 10 8 R then annealed in the range 280 to 400 0 C displays little TL in the major dosimetry peak near 200 0 C. Subsequent illumination with 250 nm light reinduces the 200 0 C TL. This radiation-enabled photo-TL is roughly proportional to the square root of the enabling exposure at least to 10 8 R. (auth)

  4. Tl response of KMgF{sub 3}: Lu + PTFE at ultraviolet radiation; Respuesta Tl de KMgF{sub 3}: Lu + PTFE a radiacion ultravioleta

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez, P R [Instituto Nacional de Investigaciones Nucleares, A.P. 18 -1027, 11801 Mexico D.F. (Mexico); Alarcon, N G [Facultad de Quimica, Universidad Autonoma del Estado de Mexico. Paseo Tollocan, Esq. con Jesus Carranza, 50180 Toluca, Estado de Mexico (Mexico); Furetta, C; Azorin, J [Universidad Autonoma Metropolitana- Iztapalapa, San Rafael Atlixco 186, 09340 Mexico. D.F. (Mexico)

    2003-07-01

    Ionizing radiation has different types of interaction with a crystalline solid. However, only few effects are interesting to optimize some thermoluminescent (Tl) properties of certain Tl materials. This paper presents results obtained by irradiating KMgF{sub 3}: Lu + Ptfe Tl dosimeters with ultraviolet (UV) radiation previously exposed to gamma radiation. These results showed that those dosimeters not exposed previously to gamma radiation did not presented any Tl signal. Meanwhile, those previously submitted to gamma irradiation showed that their sensitivity was increased as the gamma dose increased. The glow curve of sensitized KMgF{sub 3}: Lu + Ptfe exposed to UV radiation, presented the dosimetric pea at 212 C. This makes this material to be promissory for measuring UV radiation. (Author)

  5. Annual dose measurements and TL-dating of ancient Egyptian pottery

    Energy Technology Data Exchange (ETDEWEB)

    Abdel-Wahab, M S; El-Fiki, S A; Abdel-Kariem, S; El-Faramawy, N [Ain Shams University, Cairo (Egypt). Faculty of Science; EL-Fiki, M A [National Institute of Standards, Cairo (Egypt); Gomaa, M [Atomic Energy Establishment, Cairo (Egypt). Nuclear Research Center

    1996-05-01

    In the course of the dating of ancient Egyptian pottery, pottery sherds were collected from three archaeological tombs in Nazlet El Samman region, Giza zone (Egypt). The annual dose from natural background was measured by gamma spectrosocopic technique as well as thermoluminescence (TL) measurements. The results of both methods are in good agreement with a consistency of 99.69%. The extracted quartz exhibited TL dating peaks at about (305 {+-} 5){sup o}C. The TL dating shows an age of 4301 {+-} 100 years for the examined pottery which belongs to the ``Fourth Dynasty`` in the ``OlKingdom`` . The uncertainties in TL dating using the additive method are much lower than that of archaeologists. (author).

  6. Annual dose measurements and TL-dating of ancient Egyptian pottery

    Science.gov (United States)

    Abdel-Wahab, M. S.; El-Fiki, S. A.; El-Fiki, M. A.; Gomaa, M.; Abdel-Kariem, S.; El-Faramawy, N.

    1996-05-01

    In the course of the dating of ancient Egyptian pottery, pottery sherds were collected from three archaeological tombs in Nazlet El Samman region, Giza zone (Egypt). The annual dose from natural background was measured by gamma spectroscopic technique as well as thermoluminescence (TL) measurements. The results of both methods are in good agreement with a consistency of 99.69%. The extracted quartz exhibited TL dating peaks at about(305 ± 5|4)°C. The TL dating shows an age of 4301 ± 100 years for the examined pottery which belongs to the "Fourth Dynasty" in the "Old Kingdom". The uncertainties in TL dating using the additive method are much lower than that of archeologists.

  7. Annual dose measurements and TL-dating of ancient Egyptian pottery

    International Nuclear Information System (INIS)

    Abdel-Wahab, M.S.; El-Fiki, S.A.; Abdel-Kariem, S.; El-Faramawy, N.; Gomaa, M.

    1996-01-01

    In the course of the dating of ancient Egyptian pottery, pottery sherds were collected from three archaeological tombs in Nazlet El Samman region, Giza zone (Egypt). The annual dose from natural background was measured by gamma spectrosocopic technique as well as thermoluminescence (TL) measurements. The results of both methods are in good agreement with a consistency of 99.69%. The extracted quartz exhibited TL dating peaks at about (305 ± 5) o C. The TL dating shows an age of 4301 ± 100 years for the examined pottery which belongs to the ''Fourth Dynasty'' in the ''OlKingdom'' . The uncertainties in TL dating using the additive method are much lower than that of archaeologists. (author)

  8. Study of /sup 201/Tl uptake by bone and bone marrow on /sup 201/Tl scintigraphy. With special reference to bone marrow abnormalities

    Energy Technology Data Exchange (ETDEWEB)

    Fujii, Tadashige; Tanaka, Masao; Hirose, Yoshiki; Hirayama, Jiro; Handa, Kenjiro; Nakanishi, Fumiko; Yano, Kesato; Ueda, Hitoshi

    1989-04-01

    Thallium-201 (Tl-201) uptake in the bone and bone marrow was examined in a total of 93 patients with various diseases. Sternal uptake of Tl-201 was observed when patients had bone marrow abnormality especially associated with hematopoietic disease. It was associated with proliferation of immature cells and of various types of bone marrow cells, especially erythroblastic and plasma cells. Whole-body Tl-201 scanning showed a high uptake (82%) in the sternum, chest, lumbar vertebrae, and pelvis. Thallium-201 was definitively taken up by the sternum in polycythemia (5/41), hemolytic anemia (2/2), iron deficiency anemia (2/2), and multiple myeloma (2/5). For leukemia, Tl-201 uptake was slight or negative. Thallium-201 scanning proved useful in visualizing bone marrow abnormality, although careful interpretation of bone and bone marrow uptake is required. (Namekawa, K).

  9. Leading the Charge for SoTL--Embracing Collaboration

    Science.gov (United States)

    Cassard, Anita; Sloboda, Brian

    2014-01-01

    The scholarship of teaching and learning (SoTL) enables colleges and universities to assess student learning and measure the outcomes by engaging in meaningful research, and to disseminate this research. The objective of this paper is to give a snapshot of and assess the current thinking behind this scholarship by presenting examples of SoTL, and…

  10. Microcomputer-Controlled Reader Systems for Archaeological and Geological TL Dating

    DEFF Research Database (Denmark)

    Bøtter-Jensen, Lars; Mejdahl, V.

    1984-01-01

    Two fully automated TL reader systems for TL dating and a manually operated reader for research purpose were put into operation during 1982-3. All systems are controlled by HP-85 or HP-86 microcomputers; thus flexibility in selection of measurement parameters, calculation of TL signals and displa...... the archaeological and geological ages. The principle of the measurement procedures are described, and dating results are presented to illustrate the performance of the systems...

  11. Tl-201 and Tc-99m-DTPA neuro-SPECT in cerebral radiation necrosis

    International Nuclear Information System (INIS)

    Cleto, E.M. Jr.; Holmes, R.A.; Gumerlock, M.K.; Cabeen, M.; Logan, K.W.; Hoffman, T.J.

    1992-01-01

    The results in 3 cases of radiation necrosis demonstrate that by using both radionuclides Tl-201 and Tc-99m-DTPA, one can provide a semi-quantitative method to differentiate recurrent tumor from radiation necrosis. Focally increased cerebral Tl-201 activity in irradiated brain tumor patients is not specific for tumor recurrence, but when used in combination with DTPA, one is able to estimate the amount of Tl-201 activity resulting from increased blood-brain barrier permeability. If the average Tl-201 index is less than the average Tc-99m-DTPA index it suggests that the increased Tl-201 activity results primarily from blood-brain barrier breakdown. Tc-99m-DTPA SPECT, in addition to Tl-201 SPECT, or serial Tl-201 SPECT imaging may increase the accuracy of brain scintigraphy in differentiating radiation necrosis from tumor recurrence. To verify these preliminary findings, we are in the process of analyzing additional SPECT data on 9 more patients with malignant brain tumors. Using a slightly different method of quantifying Tl- 201/Tc-99m-DTPA ratios (computing the ratio of intralesional Tl-201 or Tc-99m-DTPA activity compared to adjacent scalp activity), patients with tumor recurrence have higher Tl-201/Tc-99m-DTPA ratios compared to those with radiation necrosis (verbal communication with Dr. Mary K. Gumerlock). (orig.) [de

  12. Benchmarking NaI(Tl) Electron Energy Resolution Measurements

    International Nuclear Information System (INIS)

    Mengesha, Wondwosen; Valentine, J D.

    2002-01-01

    A technique for validating electron energy resolution results measured using the modified Compton coincidence technique (MCCT) has been developed. This technique relies on comparing measured gamma-ray energy resolution with calculated values that were determined using the measured electron energy resolution results. These gamma-ray energy resolution calculations were based on Monte Carlo photon transport simulations, the measured NaI(Tl) electron response, a simplified cascade sequence, and the measured electron energy resolution results. To demonstrate this technique, MCCT-measured NaI(Tl) electron energy resolution results were used along with measured gamma-ray energy resolution results from the same NaI(Tl) crystal. Agreement to within 5% was observed for all energies considered between the calculated and measured gamma-ray energy resolution results for the NaI(Tl) crystal characterized. The calculated gamma-ray energy resolution results were also compared with previously published gamma-ray energy resolution measurements with good agreement (<10%). In addition to describing the validation technique that was developed in this study and the results, a brief review of the electron energy resolution measurements made using the MCCT is provided. Based on the results of this study, it is believed that the MCCT-measured electron energy resolution results are reliable. Thus, the MCCT and this validation technique can be used in the future to characterize the electron energy resolution of other scintillators and to determine NaI(Tl) intrinsic energy resolution

  13. {sup 201}Tl, {sup 99m}Tc-MIBI, {sup 99m}Tc-tetrofosmin and {sup 99m}Tc-furifosmin: relative retention and clearance kinetics in retrogradely perfused guinea pig hearts

    Energy Technology Data Exchange (ETDEWEB)

    Schaefer, Wolfgang M.; Moka, Detlef E-mail: detlef.moka@uni-koeln.de; Brockmann, Holger A.; Schomaecker, Klaus; Schicha, Harald

    2002-02-01

    Myocellular kinetics of {sup 201}Tl, {sup 99m}Tc-MIBI, {sup 99m}Tc-tetrofosmin and {sup 99m}Tc-furifosmin were investigated using retrogradely-perfused guinea-pig hearts. Relative retention decreased in the order {sup 99m}Tc-MIBI {yields}{yields} implies {sup 99m}Tc-tetrofosmin {yields}{yields} implies {sup 99m}Tc-furifosmin. {sup 201}Tl and {sup 99m}Tc-MIBI exhibited bi- (t1,t2), {sup 99m}Tc-tetrofosmin and {sup 99m}Tc-furifosmin triexponential (t1,t2,t3) time-activity-curves. Latest-phase elimination-half-life increased from {sup 201}Tl (t2) {yields}{yields} implies {sup 99m}Tc-MIBI (t2) {yields}{yields} implies {sup 99m}Tc-tetrofosmin (t3) {yields}{yields} implies {sup 99m}Tc-furifosmin (t3), showing a significant increase in deteriorating myocardium for all tracers but {sup 99m}Tc-furifosmin. Delayed elimination in deteriorating myocardium explains at least partly the redistribution phenomenon of {sup 201}Tl, and suggests a similar phenomenon for {sup 99m}Tc-MIBI and {sup 99m}Tc-tetrofosmin.

  14. Systems Tl2MoO4-E(MoO4)2, where E=Zr or Hf, and the crystal structure of Tl8Hf(MoO4)6

    International Nuclear Information System (INIS)

    Bazarov, B.G.; Bazarova, Ts.T.; Fedorov, K.N.; Bazarova, Zh.G.; Chimitova, O.D.; Klevtsova, R.F.; Glinskaya, L.A.

    2006-01-01

    Systems Tl 2 MoO 4 -E(MoO 4 ) 2 (E=Zr, Hf) were studied by X-ray diffraction, differential thermal analysis and IR spectroscopy. Formation of Tl 8 E(MoO 4 ) 6 and Tl 2 E(MoO 4 ) 2 compounds was established. Phase T-x diagrams of the Tl 2 MoO 4 -Zr(MoO 4 ) 2 system were constructed. Monocrystals were grown, and structure of Tl 8 Hf(MoO 4 ) 6 was studied. The compound is crystallized in monoclinic syngony with elementary cell parameters a=9.9688(6), b=18.830(1), c=7.8488(5) A, β=108.538(1) Deg, Z=2, sp. gr. C2/m. The isolated group [HfMo 6 O 24 ] 8- is responsible for fundamental fragment of the structure. Three varieties of crystallographically independent Tl-polyhedra fill space evenly between fragments [HfMo 6 O 24 ] 8- forming three-dimensional form [ru

  15. Evaluation of coronary hemodynamics and exercise 201Tl-myocardial scintigraphy in patients with vasospastic angina

    International Nuclear Information System (INIS)

    Matsumura, Kentaro; Nakase, Emiko; Haiyama, Tohru; Hasegawa, Akira; Saito, Takayuki

    1992-01-01

    To clarify the coronary hemodynamics and myocardial perfusion in patients with vasospastic angina, we performed exercise 201 Tl-myocardial scintigraphy (planar and SPECT) in 72 patients and left coronary digital subtraction angiography (DSA) in 37 patients without significant organic coronary artery stenosis. Coronary artery spasm was documented by coronary angiography in all patients. Fifty-four patients (75%) developed exercise-induced 201 Tl-myocardial perfusion defect on SPECT. 201 Tl pulmonary uptake (L/H) was significantly increased in patients with vasospastic angina. Especially, L/H was higher in patients with multiple small perfusion defect on 201 Tl-SPECT, so that exercise-induced left ventricular dysfunction existed in patients with vasospastic angina and especially in cases of multiple small perfusion defect on 201 Tl-SPECT. The left coronary circulation time (CCT) was prolonged in patients with vasospastic angina. The mechanism of prolonged CCT is still unknown, but we suspected that prolonged CCT was induced by increased peripheral coronary vascular resistance in patients with vasospastic angina. It was concluded that the peripheral coronary circulation was disturbed in patients with vasospastic angina, but its abnormal coronary circulation had no relation to location of spasm-induced vessels. We concluded that impaired coronary microcirculation was taken a part of pathophysiology in vasospastic angina. (author)

  16. Dielectric and baric characteristics of TlS single crystal

    Energy Technology Data Exchange (ETDEWEB)

    Mustafaeva, S.N., E-mail: solmust@gmail.com [Institute of Physics, ANAS, G. Javid prosp. 33, Az 1143 Baku (Azerbaijan); Asadov, M.M. [Institute of Chemical Problems, ANAS, G. Javid prosp. 29, Az 1143 Baku (Azerbaijan); Ismailov, A.A. [Institute of Physics, ANAS, G. Javid prosp. 33, Az 1143 Baku (Azerbaijan)

    2014-11-15

    The investigation of the frequency dependences of the dielectric coefficients and ac-conductivity of the TlS single crystals made it possible to elucidate the nature of dielectric loss and the charge transfer mechanism. Moreover, we evaluated the density and energy spread of localized states near the Fermi level, the average hopping time and the average hopping length. It was shown that the dc-conductivity of the TlS single crystals can be controlled by varying the hydrostatic pressure. This has opened up possibilities for using TlS single crystals as active elements of pressure detectors.

  17. Phase equilibria in TlX-Cd(Zn)X (X-S, Se, Te) systems

    International Nuclear Information System (INIS)

    Gusejnov, F.Kh.; Babanly, M.B.; Kuliev, A.A.

    1982-01-01

    The methods of DTA, RPA and measurement of the alloys microhardness have been used to investigate the phase equilibria in the TlX-Zn(Cd)X systems. It is established that the TlZn(Cd)X 2 compounds, the presence of which is mentioned in the literature earlier, do not form in these systems. The TlSe-Zn(Cd)Se systems apply to the simple eutectic type and characterized by digenerated eutectic near the TlSe. Thermodynamical analysis of the liquidus of the TlSe-CdSe and TlTe-Zn(Cd)Te systems in approximation of the regular solutions, taking into account the dissociation of tallium chalcogenides in liquid phase, is made

  18. TL Dating Technique Based on a Trap Model and its Application as a Geochronometer for Granitic Quartz

    International Nuclear Information System (INIS)

    Han, Y.; Li, H.; Tso, Y.W.

    1999-01-01

    A trap model is introduced to describe the behaviours of both thermally sensitive and radiation sensitive TL traps. The former are relatively shallow traps. The latter are deep traps, in which population increases with exposure to alpha dose. Thermal decay of both types of traps at ambient temperature is dependent on the trap lifetimes. A trap's population can be measured as TL sensitivity to a laboratory test dose. The trap model has been supported by observations of age dependent TL signals from granitic quartz samples with different crystallisation ages. The trap lifetimes are from 1.98 x 10 9 to 5.36 x 10 15 years estimated using the isothermal decay experiment with the assumption of first order kinetics. Dating techniques are proposed based on the trap model. For old granites (>400 Ma), ages can be obtained by measuring the total exposed alpha dose using the additive alpha dose method, whereas for young granites (<400 Ma), ages can also be obtained by interpolating the TL sensitivity to a curve of TL sensitivities for known ages. (author)

  19. Expanding the Teaching Commons: Making the Case for a New Perspective on SoTL

    Directory of Open Access Journals (Sweden)

    Kim A. Case, PhD

    2013-08-01

    Full Text Available As a reflection on O’Meara, Terosky, and Neumann’s (2011 work on scholarship of teaching and learning (SoTL faculty development, this essay describes the benefits of SoTL to individual faculty and university goals. In support and expansion of arguments advanced by O’Meara et al., this work calls for the use of SoTL faculty development to promote the shared teaching commons, active recruitment of new SoTL scholars, institutionalization of SoTL values, and integration of SoTL initiatives in both teaching centers and research-focused development offices.

  20. Predictive values of early rest/24 hour delay Tl-201 perfusion SPECT for wall motion improvement in patients with acute myocardial infarction after reperfusion

    International Nuclear Information System (INIS)

    Hyun, In Young; Kwan, June

    1998-01-01

    We studied early rest/24 hour delay Tl-201 perfusion SPECT for prediction of wall motion improvement after reperfusion in patients with acute myocardial infarction. Among 17 patients (male/female=11/6, age: 59±13) with acute myocardial infarction, 15 patients were treated with percutaneous transcoronary angioplasty (direct:2, delay:11) and intravenous urokinase (2). Spontaneous resolution occurred in infarct related arteries of 2 patients. We confirmed TIMI 3 flow of infarct-related artery after reperfusion in all patients with coronary angiography. We performed rest Tl-201 perfusion SPECT less then 6 hours after reperfusion and delay Tl-201 perfusion SPECT next day. Tl-201 uptake was visually graded as 4 point score from normal (0) to severe defect (3). Rest Tl-201 uptake ≤2 or combination of rest Tl-201 uptake ≤2 or late reversibility were considered to be viable. Myocardial wall motion was graded as 5 point score from normal (1) to dyskinesia (5). Myocardial wall motion was considered to be improved when a segment showed an improvement ≥1 grade in follow up echo compared with the baseline values. Among 98 segments with wall motion abnormality, the severity of myocardial wall motion decrease was as follow: mild hypokinesia: 18/98 (18%), severe hypokinesia: 28/98 (29%), akinesia: 51/98 (52%), dyskinesia: 1/98 (1%). The wall motion improved in 85%. Redistribution (13%), and reverse redistribution (4%) were observed in 24 hour delay SPECT. Positive predictive value (PPV) and negative predictive value (NPV) of combination of late reversibility and rest Tl-201uptake were 99%, and 54%.PPV and NPV of rest Tl-201 uptake were 100% and 52% respectively. Predictive values of comibination of rest Tl-201 uptake and late reversibility were not significantly different compared with predictive values of rest Tl-201 uptake only. We conclude that early Tl-201 perfusion SPECT predict myocardial wall motion improvement with excellent positive but relatively low negative

  1. First-principles prediction of Tl/SiC for valleytronics

    KAUST Repository

    Xu, Zhen; Zhang, Qingyun; Shen, Qian; Cheng, Yingchun; Schwingenschlö gl, Udo; Huang, Wei

    2017-01-01

    Recently, monolayer Tl on a Si or Ge substrate has been proposed for potential valleytronic systems. However, the band gaps of these systems are less than 0.1 eV, which is too small to be applied because an electric field or magnetic doping will reduce the band gaps further for the systems to become metallic. Here, we investigate SiC as an alternative substrate. By first-principles calculations we demonstrate that monolayer Tl can be grown on SiC. There are two valleys around the K/K′ points and the Berry curvature shows that the two valleys are inequivalent, indicating valley pseudospin. Moreover, due to the larger band gap of SiC (3.3 eV), the band gap of the Tl/SiC system is 0.6 eV, which is large enough for valley manipulation. Furthermore, we demonstrate that Cr doping can achieve valley polarization. Our study shows that the Tl/SiC system is promising for valleytronic applications.

  2. First-principles prediction of Tl/SiC for valleytronics

    KAUST Repository

    Xu, Zhen

    2017-09-22

    Recently, monolayer Tl on a Si or Ge substrate has been proposed for potential valleytronic systems. However, the band gaps of these systems are less than 0.1 eV, which is too small to be applied because an electric field or magnetic doping will reduce the band gaps further for the systems to become metallic. Here, we investigate SiC as an alternative substrate. By first-principles calculations we demonstrate that monolayer Tl can be grown on SiC. There are two valleys around the K/K′ points and the Berry curvature shows that the two valleys are inequivalent, indicating valley pseudospin. Moreover, due to the larger band gap of SiC (3.3 eV), the band gap of the Tl/SiC system is 0.6 eV, which is large enough for valley manipulation. Furthermore, we demonstrate that Cr doping can achieve valley polarization. Our study shows that the Tl/SiC system is promising for valleytronic applications.

  3. First approval procedure of the TL dosimetric service of the NPP in Slovenia

    International Nuclear Information System (INIS)

    Janzekovic, H.; Krizman, M.; Pucelj, B.; Stuhec, M.; Zdesar, U.

    2001-01-01

    The individual dosimetry of exposed workers in a NPP is one of the essential parts which demonstrates the radiation protection standards achieved in a facility. According to the current legislation the Ministry of Health of the Republic of Slovenia has the authority to grant approvals to personal dosimetric services which perform the dosimetric monitoring of workers in Slovenia. Due to the fact that the detailed approval procedure is not given in national regulations, the Ministry of Health in 2000 established a group of experts with the task to prepare technical and organising requirements for such approval. Based on international documents [1,2,3] the Approval procedure for the thermoluminescence dosimetric (TL) services was created. Following this procedure the assessment of the TL dosimetric service in the NPP was performed. The problems related to the technical and organising requirements with the emphasise on the QA/QC criteria of the TL dosimetric service will be discussed.(author)

  4. Reverse 201Tl myocardial redistribution induced by coronary artery spasm

    International Nuclear Information System (INIS)

    Xiang Dingcheng; Yin Jilin; Gong Zhihua; Xie Zhenhong; Zhang Jinhe; Wen Yanfei; Yi Shaodong

    2010-01-01

    Objective: To investigate the mechanism of reverse redistribution (RR) on dipyridamole 201 Tl myocardial perfusion studies in the patients with coronary artery spasm. Methods: Twenty-six patients with coronary artery spasm and presented as RR on dipyridamole 201 Tl myocardial perfusion studies were enlisted as RR group, while other 16 patients with no coronary artery stenosis nor RR were enlisted as control group. Dipyridamole test was repeated during coronary angiography. Corrected thrombolysis in myocardial infarction (TIMI) frame count (CTFC) and TIMI myocardial perfusion grade (TMPG) were measured at RR related and non-RR related coronary arteries before and after dipyridamole infusion respectively. All of the data were analyzed by Student's t-test or χ 2 -test and correlation analysis. Results: Coronary artery angiography showed slower blood flow and lower myocardial perfusion in RR related vessels when compared with non-RR related vessels in RR group, but there was no significant difference among the main coronary arteries in control group. The perfusion defects of RR area at rest were positively related to slower blood velocity at corresponding coronary arteries (r = 0.79, t =10.18, P 0.05). Conclusion: RR is related to the decreased blood flow and myocardial perfusion induced by coronary artery spasm at rest, which may be improved by stress test such as intravenous dipyridamole infusion. (authors)

  5. Stability of detecting system using NaI(Tl)

    International Nuclear Information System (INIS)

    Zhuo Yunshang; Lei Zhangyun; Zen Yu; Gong Hua

    1996-01-01

    A detecting system using NaI(Tl) is widely used in research and industry of nuclear science and other fields. For providing the high accuracy and working well under inclement environment, the stability of detecting system using NaI(Tl) is very important. The variation of environment temperature, the change of counting rate and long time continuous working of detector will cause un-negligible effect on the measurement. Three approaches were used. They are: 1) temperature control (It makes the effect of the variation of environment temperature on the measurement negligible.); 2) spectrum stabilizing (It adjust the peak position of the spectrum when the counting rate changes.); and 3) auto-checking and adjusting (It adjusts the drift of the NaI(Tl) detecting system when it works continuously)

  6. Investigating the origins of double photopeaks in CsI:Tl samples through activator mapping

    Science.gov (United States)

    Onken, Drew R.; Gridin, Sergii; Williams, Richard T.; Williams, Charles B.; Donati, George L.; Gayshan, Vadim; Vasyukov, Sergey; Gektin, Alex

    2018-06-01

    Careful examination of the origins of double photopeaks in CsI:Tl provides a foundation for exploring the relationship between activator homogeneity and photopeak resolution in scintillators. In rare cases, certain CsI:Tl crystals exhibit a second photopeak in the pulse-height spectrum. A combination of optical mapping and ICP-MS measurements reveals the presence of two distinct regions with differing Tl concentrations in these crystals. The oscillator strength of the 299 nm absorption A-band of Tl in CsI was measured to be 0.0526 ± 0.0008; this parameter can be used to quantify activator concentration from the optical absorption. Using published measurements of luminescence intensity versus Tl concentration, the distributions of Tl measured from optical absorption maps of the samples were reconstructed into photopeaks in good agreement with experiment. The distribution of Tl concentrations in these particular crystals allowed examining luminescence pulse shape as a function of Tl concentration.

  7. Persistent luminescence, TL and OSL characterization of beta irradiated SrAl2O4:Eu2+, Dy3+ combustion synthesized phosphor

    International Nuclear Information System (INIS)

    Zúñiga-Rivera, N.J.; García, R.; Rodríguez-Mijangos, R.; Chernov, V.; Meléndrez, R.; Pedroza-Montero, M.; Barboza-Flores, M.

    2014-01-01

    The persistent luminescence (PLUM), thermoluminescence (TL) and optically stimulated luminescence (OSL) properties of strontium aluminates co-doped with Eu +2 and Dy +3 exposed to beta radiation is reported. The phosphor was synthesized by the combustion synthesis method employing a highly exothermic redox reaction between the metal nitrates [Al(NO 3 ) 3 , Sr(NO 3 ) 2 , Eu(NO 3 ) 3 and Dy(NO 3 ) 3 ] and organic fuel carbohydrazide (CH 6 N 4 O). The long decay PLUM emission, TL and OSL were measured as a function of beta radiation dose. A wide emission band centered at 510 nm (green) related to Eu 2+ ions and lattice defects were observed for the synthesized samples. The presence of a variety of defects and aggregates were responsible for the observed broad 100 °C peaked TL glow curve of the irradiated sample which is composed of several overlapped TL peaks. The existence of multiple trapping levels, with different trapping/detrapping probabilities, is behind the particular features for the PLUM, TL and OSL emissions. We conclude that in the SrAl 2 O 4 :Eu 2+ , Dy 3+ phosphors, the low temperature TL peaked around 30–75 °C is responsible for the PLUM emission and those around 100 °C were related to very stable trapping states which provide suitable radiation storage properties to be used as a PLUM/TL/OSL radiation phosphor

  8. Influence of Impurities on the Radiation Response of the TlBr Semiconductor Crystal

    Directory of Open Access Journals (Sweden)

    Robinson Alves dos Santos

    2017-01-01

    Full Text Available Two commercially available TlBr salts were used as the raw material for crystal growths to be used as radiation detectors. Previously, TlBr salts were purified once, twice, and three times by the repeated Bridgman method. The purification efficiency was evaluated by inductively coupled plasma mass spectroscopy (ICP-MS, after each purification process. A compartmental model was proposed to fit the impurity concentration as a function of the repetition number of the Bridgman growths, as well as determine the segregation coefficients of impurities in the crystals. The crystalline structure, the stoichiometry, and the surface morphology of the crystals were evaluated, systematically, for the crystals grown with different purification numbers. To evaluate the crystal as a radiation semiconductor detector, measurements of its resistivity and gamma-ray spectroscopy were carried out, using 241Am and 133Ba sources. A significant improvement of the radiation response was observed in function of the crystal purity.

  9. Gamma-radiation-induced change in the activation energy of TL traps in LiRbSO[sub 4]:Tl

    Energy Technology Data Exchange (ETDEWEB)

    Kassem, M.E.; El-Kolaly, M.A.; Al-Houty, L.I. (Qatar Univ., Doha (Qatar). Dept. of Physics)

    1994-06-01

    Thermoluminescence (TL) measurements were carried out for pure and doped LiRbSO[sub 4], with different concentrations of thallium (Tl). The glow-curve range of measurement is between room temperature up to 300[sup o]C. The radiation absorbed dose is in the range 56-3.2 x 10[sup 5] Gy. The results show that both pure and doped samples have glow peak temperatures that are dose dependent, and vary between 70-80[sup o]C and 140-170[sup o]C for pure and doped samples respectively. Doped samples display double peaks that increase with dopant concentration up to about 0.7% wt. The second peak which occurs at high temperature increases linearly with dose up to 4500 Gy. From the results it is proposed that LiRbSO[sub 4] doped with 0.7% Tl can be used for dosimetric purposes in this range. The activation energies of structural transitions are estimated and the results are discussed on the basis of radiation-induced stable dipoles in the random field system. (Author).

  10. Exploring the thermoelectric and magnetic properties of uranium selenides: Tl{sub 2}Ag{sub 2}USe{sub 4} and Tl{sub 3}Cu{sub 4}USe{sub 6}

    Energy Technology Data Exchange (ETDEWEB)

    Azam, Sikander; Khan, Saleem Ayaz [New Technologies – Research Center, University of West Bohemia, Univerzitni 8, 30614 Pilsen (Czech Republic); Din, Haleem Ud [Department of Physics, Hazara University, Mansehra (Pakistan); Khenata, Rabah [Laboratoire de Physique Quantique et de Modélisation Mathématique (LPQ3M), Département de Technologie, Université de Mascara, Mascara 29000 (Algeria); Goumri-Said, Souraya, E-mail: sosaid@alfaisal.edu [College of Science, Physics department, Alfaisal University, P.O. Box 50927, Riyadh 11533 (Saudi Arabia)

    2016-09-01

    The electronic, magnetic and thermoelectric properties of Tl{sub 2}Ag{sub 2}USe{sub 4} and Tl{sub 3}Cu{sub 4}USe{sub 6} compounds were investigated using the full potential linear augmented plane wave (FP-LAPW) method based on the density functional theory (DFT). The exchange correlation was treated with the generalized gradient approximation plus optimized effective Hubbard parameter and spin–orbit coupling (GGA+U+SOC). The present uranium selenides show narrow direct energy band gap values of 0.7 and 0.875 eV for Tl{sub 2}Ag{sub 2}USe{sub 4} and Tl{sub 3}Cu{sub 4}USe{sub 6} respectively. For both selenides U-d/f states are responsible for electrical transport properties. Uranium atoms were the most contributors in the magnetic moment compared to other atoms and show ferromagnetic nature. The spin density isosurfaces show the polarization of neighboring atoms of Uranium, such as silver/copper and selenium. Thermoelectric calculations reveal that Tl{sub 3}Cu{sub 4}USe{sub 6} is more suitable for thermoelectric device applications than Tl{sub 2}Ag{sub 2}USe{sub 4}. - Highlights: • Electronic, magnetic and thermoelectric properties of uranium selenides are investigated with DFT. • They show a narrow direct energy band gap of 0.7 and 0.875 eV. • U-d/f states are responsible for electrical transport properties. • Tl{sub 3}Cu{sub 4}USe{sub 6} is more suitable for thermoelectric device applications than Tl{sub 2}Ag{sub 2}USe{sub 4}.

  11. A new spectroscopic imager for X-rays from 0.5 keV to 150 keV combining a pnCCD and a columnar CsI(Tl) scintillator

    Science.gov (United States)

    Schlosser, D. M.; Hartmann, R.; Kalok, D.; Bechteler, A.; Abboud, A.; Shokr, M.; Çonka, T.; Pietsch, U.; Strüder, L.

    2017-04-01

    By combining a low noise fully depleted pnCCD detector with a columnar CsI(Tl) scintillator an energy dispersive spatial resolving detector can be realized with a high quantum efficiency in the range from below 0.5 keV to above 150 keV. The used scintillator system increases the pulse height of gamma-rays converted in the CsI(Tl), due to focusing properties of the columnar scintillator structure by reducing the event size in indirect detection mode (conversion in the scintillator). In case of direct detection (conversion in the silicon of the pnCCD) the relative energy resolution is 0.7% at 122 keV (FWHM = 850 eV) and the spatial resolution is less than 75 μm. In case of indirect detection the relative energy resolution, integrated over all event sizes is about 9% at 122 keV with an expected spatial precision of below 75 μm.

  12. Measurement of the infarcted area by 201Tl myocardial emission CT

    International Nuclear Information System (INIS)

    Tamaki, Shunichi; Murakami, Tomoyuki; Kambara, Hirofumi

    1982-01-01

    201 Tl-ECT was performed in 28 cases 4 weeks after the onset of acute myocardial infarction to calculate the volume of infarction for comparison with the CK-MB infarction size obtained in the acute phase. The infarct area obtained by two-dimensional 201 Tl scintigraphy in 18 cases treated by the conventional method showed a positive correlation with the CK-MB infarct size, but the volume of infarction by 201 Tl-ECT produced a better correlation. In the group with successful thrombolysis, the serum CK-MB level reached a peak soon after the onset, accompanied by release of more CK-MB for a constant volume of infarction obtained by 201 Tl-ECT, as compared with the group with unsuccessful thrombolysis or conventional therapy. This suggests the involvement of washout phenomenon by reperfusion. Although there are some limitations, the three-dimensional detection of the distribution of myocardial blood flow by 201 Tl-ECT is useful, covering disadvantages of two-dimensional images. (Chiba, N.)

  13. TL dating of vases with elephant ears in Yuan Dynasty

    International Nuclear Information System (INIS)

    Xia Junding; Wang Weida; Leung, P.L.

    2005-01-01

    Thermoluminescence (TL) dating using an activation method in pre-dose technique was described. Three vases in underglaze blue with elephant ears and one vase in underglaze red with elephant ears in Yuan Dynasty were dated by this method. The results show that the TL ages are all less than 100 a B.P., and in which sbc 648 and sbc 649 were imitated in recent years. This method is quick, convenient and reliable for porcelain dating with the age of less than 1000 a B.P.. As a comparison, a porcelain sample with underglaze blue in Yuan Dynasty was dated too, and its TL age is 620 ± 140 B.P.. In addition, some complex factors associated with dating have been discussed and a resolution has been raised, which will help improve the accuracy of TL dating. (authors)

  14. Dipyridamole 201Tl scintigraphy in the evaluation of prognosis after myocardial infarction

    International Nuclear Information System (INIS)

    Okada, R.D.; Glover, D.K.; Leppo, J.A.

    1991-01-01

    Dipyridamole 201Tl imaging has been proposed as an alternative to exercise ECG testing for the prehospital discharge evaluation of patients recovering from myocardial infarction. The rationale is that many postinfarction patients with exercise-induced ischemia experience later cardiac events, and the sensitivity of predischarge exercise ECG testing in patients with multivessel disease ranges from only 45% to 62%. In addition, several groups of investigators have shown the sensitivity of submaximum exercise 201Tl imaging to be less than ideal. This report summarizes the current status of dipyridamole 201Tl imaging in the period of 1-13 days after myocardial infarction. Although the number of studies performed to date is limited, the following conclusions can be drawn: dipyridamole 201Tl imaging after myocardial infarction was associated with no serious side effects, and those present could be quickly reversed with aminophylline; redistribution with dipyridamole 201Tl images definitely correlates with prognosis after uncomplicated myocardial infarction; dipyridamole 201Tl imaging is definitely useful in patients unable to exercise for a variety of reasons; and future studies are definitely indicated to further define the role of dipyridamole 201Tl imaging for assessing prognosis, especially in those patients undergoing interventional therapy after acute myocardial infarction

  15. Tl response of KMgF3: Lu + PTFE at ultraviolet radiation

    International Nuclear Information System (INIS)

    Gonzalez, P.R.; Alarcon, N.G.; Furetta, C.; Azorin, J.

    2003-01-01

    Ionizing radiation has different types of interaction with a crystalline solid. However, only few effects are interesting to optimize some thermoluminescent (Tl) properties of certain Tl materials. This paper presents results obtained by irradiating KMgF 3 : Lu + Ptfe Tl dosimeters with ultraviolet (UV) radiation previously exposed to gamma radiation. These results showed that those dosimeters not exposed previously to gamma radiation did not presented any Tl signal. Meanwhile, those previously submitted to gamma irradiation showed that their sensitivity was increased as the gamma dose increased. The glow curve of sensitized KMgF 3 : Lu + Ptfe exposed to UV radiation, presented the dosimetric pea at 212 C. This makes this material to be promissory for measuring UV radiation. (Author)

  16. Evidence for charge Kondo effect in superconducting Tl-doped PbTe

    Energy Technology Data Exchange (ETDEWEB)

    Fisher, I

    2010-01-11

    We report results of low-temperature thermodynamic and transport measurements of Pb{sub 1-x}Tl{sub x}Te single crystals for Tl concentrations up to the solubility limit of approximately x = 1.5%. For all doped samples, we observe a low-temperature resistivity upturn that scales in magnitude with the Tl concentration. The temperature and field dependence of this upturn are consistent with a charge Kondo effect involving degenerate Tl valence states differing by two electrons, with a characteristic Kondo temperature T{sub K} {approx} 6 K. The observation of such an effect supports an electronic pairing mechanism for superconductivity in this material and may account for the anomalously high T{sub c} values.

  17. Investigation of the gamma radiation from the inelastic scattering of 2.75 MeV on 203Tl and 205Tl

    International Nuclear Information System (INIS)

    Hegewisch, S.

    1976-01-01

    The experimental presupositions for the measurements of (n,n'γ) reactions with time of flight discrimination have been established. By an investigation of the isotopes 203 Tl and 205 Tl with this method 120 gamma-transitions could be determined. The exact evaluation of their energies and intensities led to a completion of the level diagrams. The enrgies could be determined with a precision nearly one order of magnitude higher than the values existing hither to. (orig./WL) [de

  18. Clinical application of 201Tl scintigraphy in patients with cold thyroid nodules

    International Nuclear Information System (INIS)

    Tonami, N.; Bunko, H.; Michigishi, T.; Kuwajima, A.; Hisada, K.

    1978-01-01

    201 Tl-chloride scintigraphy was performed in 45 patients with cold thyroid nodules. The 201 Tl scintigram was positive in 17 of 18 thyroid patients with cancer (94.4%), 8 of 20 patients with an adenoma (40.0%), 1 of 2 adenomatous goiter patients (50.5%), and all of 5 cases of chronic thyroiditis (100.0%). When the cold nodule was demonstrated to be positive with 201 Tl, the statistical chance of the lesion being a cellular one was 100.0% and a risk of its malignancy was 54.8%. On the other hand, the nodule with negative 201 Tl concentration had a 14.3% chance of cellularity and a 7.1% risk of malignancy. Thus, 201 Tl scintigraphy is of use in the differential diagnosis of the cold thyroid nodule

  19. Comparison of functional parameters of CsI:Tl crystals and thick films

    International Nuclear Information System (INIS)

    Fedorov, A.; Gektin, A.; Lebedynskiy, A.; Mateychenko, P.; Shkoropatenko, A.

    2013-01-01

    500 mkm thick CsI:Tl columnar films can be produced using thermal evaporation in vacuum by sublimation of the same bulk crystal. Comparison of afterglow and radiation stability of deposited CsI:Tl films with source crystal was the aim of current work. It is shown that the afterglow in the films is always below its level in initial single crystal. It was ascertained that the annealing atmospheres influence the processes leading to the activator depletion of the films during the thermal processing. -- Highlights: ► Thick CsI:Tl columnar films were obtained by thermal evaporation in vacuum. ► Radiation stability of such CsI:Tl films appears to be better than that of crystal. ► CsI:Tl film parameters can be modified by annealing in different atmospheres

  20. Experimental determination of relative light conversion factors of TLD-100 for protons with energies from 2.0 to 9.0 MeV

    International Nuclear Information System (INIS)

    Schmidt, P.; Fellinger, J.; Henniger, J.; Huebner, K.

    1988-01-01

    The efficiency of thermoluminescent (TL) detectors to heavy charged particles is described by the so-called light conversion factor η. Relative light conversion factors for protons, alphas and heavier recoils are needed for the calculation of the neutron sensitivity of TL detectors. Such light conversion factors can be determined experimentally. In this paper a method is presented for the experimental determination of relative light conversion factors. Using the experimental arrangement described, relative light conversion factors for LiF material (TLD-100) for protons were determined. In LiF the relative main peak (peak V) efficiency is always lower than 1. It increases with increasing proton energy whereas the relative efficiency of the high temperature peak (peak VI) shows an opposite dependence on the proton energy. Relative light conversion factors for peak VI clearly exceed 1. (orig.)

  1. Superdeformation studies in the odd-odd nucleus {sup 192}Tl

    Energy Technology Data Exchange (ETDEWEB)

    Fischer, S.; Carpenter, M.P.; Janssens, R.V.F. [and others

    1995-08-01

    The study of yrast and near-yrast structures of odd-odd nuclei to high spins is somewhat limited due to the complexity of the spectra resulting from the many proton-neutron couplings near the Fermi surface. In superdeformed nuclei, the number of available protons and neutrons near the Fermi surface is somewhat limited due to the presence of large-shell gaps which stabilize the nuclear shape. A relatively small number of available neutron and proton configurations can lead to fragmentation of the SD intensity into a number of different bands. Two good examples of this phenomenon were found in {sup 192}Tl and {sup 194}Tl where the presence of six superdeformed bands were reported in both nuclei. We reexamined {sup 192}Tl at Gammasphere using the {sup 160}Gd({sup 37}Cl,5n) reaction at 178 MeV to populate states in the superdeformed well of this nucleus. While our previous study on {sup 192}Tl at ATLAS was very successful, a number of questions remained which formed the basis of our objectives in this experiment: obtain better {gamma}-ray energies for the known transitions and identify higher spin members in each band; determine how the bands feed the known yrast states in {sup 192}Tl as well as determine the complete spectrum in coincidence with the SD bands; look for M1 transitions connecting proposed signature partners; and attempt to identify other excitations in the superdeformed well. Analysis is underway and four of the six bands were confirmed. The reasons that two of the reported bands were not observed in this latest work is still under investigation. As of this time, no other superdeformed bands were identified in the data. Two of the confirmed SD bands have a constant moment of inertia and show indications of cross-talk between each other. This observation is not unexpected since the calculated M1 rates for the proposed configuration of the band, {pi}{sub 13/2} x {upsilon}j{sub 15/2}, indicate that M1 transitions linking the two SD bands should be observed.

  2. Scintigraphic detection of ischemic and other myocardial lesions using 201Tl

    International Nuclear Information System (INIS)

    Duska, F.; Novak, J.; Vizda, J.; Kubicek, J.; Kafka, P.

    1981-01-01

    Current knowledge of the myocardium scintiscanning using 201 Tl is briefly outlined. The principle is shown of 201 Tl cumulation in a healthy myocardium and the use of the radionuclide is justified. Heart scintiscanning after exercise or after administration of drugs increasing the blood flow through the coronaries allows detecting latent ischaemic heart disease. 201 Tl scintigraphy can also be used for diagnosing the myocardial infarction, angina pectoris and other heart diseases. (J.P.)

  3. Vortex states of Tl2Ba2CuO6+δ studied via 205Tl NMR at 2 tesla

    International Nuclear Information System (INIS)

    Itoh, Yutaka; Michioka, Chishiro; Yoshimura, Kazuyoshi; Hayashi, Akihiko; Ueda, Yutaka

    2005-01-01

    We report a 205 Tl NMR study of vortex states in an aligned polycrystalline sample of an overdoped high-T c superconductor, Tl 2 Ba 2 CuO 6+δ (Tc - 85 K), at a magnetic field of 2 T along the c axis. We observed an imperfect vortex lattice, so-called Bragg glass, at T=5 K, the coexistence of vortex solid and vortex liquid between 10 and 60 K, and vortex melting between 65 and 85 K. No evidence for local antiferromagnetic ordering at vortex cores was found for our sample. (author)

  4. Highly efficient removal of trace thallium from contaminated source waters with ferrate: Role of in situ formed ferric nanoparticle.

    Science.gov (United States)

    Liu, Yulei; Wang, Lu; Wang, Xianshi; Huang, Zhuangsong; Xu, Chengbiao; Yang, Tao; Zhao, Xiaodan; Qi, Jingyao; Ma, Jun

    2017-11-01

    Thallium (Tl) is highly toxic to mammals and relevant pollution cases are increasing world-widely. Convenient and efficient method for the removal of trace Tl from contaminated source water is imperative. Here, the removal of trace Tl by K 2 FeO 4 [Fe(VI)] was investigated for the first time, with the exploration of reaction mechanisms. Six different types of water treatment agents (powdered activated carbon, Al 2 (SO 4 ) 3 , FeCl 3 , δ-MnO 2 , MnO 2 nano-particles, and K 2 FeO 4 ) were used for the removal of Tl in spiked river water, and K 2 FeO 4 showed excellent removal performance. Over 92% of Tl (1 μg/L) was removed within 5 min by applying 2.5 mg/L of K 2 FeO 4 (pH 7.0, 20 °C). XPS analysis revealed that in the reaction of Tl(I) with K 2 FeO 4 , Tl(I) was oxidized to Tl(III), and removed by the K 2 FeO 4 reduced ferric particles. The removal of Tl by in situ formed and ex situ formed ferric particle was examined respectively, and the results revealed that the removal of trace Tl could be attributed to the combination of adsorption and coprecipitation processes. The hydrodynamic size of the reduced particle from K 2 FeO 4 ranged from 10 nm to 100 nm, and its surface was negatively charged under neutral pH condition. These factors were conducive for the efficient removal of Tl by K 2 FeO 4 . The effects of solution pH, coexisting ions (Na + , Ca 2+ , and HCO 3 - ), humic acid, solution temperature, and reductive environment on the removal and desorption of Tl were investigated, and the elimination of Tl in polluted river water and reservoir water was performed. These results suggest that K 2 FeO 4 could be an efficient and convenient agent on trace Tl removal. Copyright © 2017. Published by Elsevier Ltd.

  5. Computerized study with 201Tl of the gold thyroid node

    International Nuclear Information System (INIS)

    Palermo, F.; Saitta, B.; Coghetto, F.; Tiberio, M.; Caldato, L.

    1982-01-01

    Because of its physical and potassium-metabolic characteristics 201 Tl is more suitable than 131 Cs for radioisotopic studies of the cold thyroid nodule, with the further diagnostic possibility of quantitatively assessing intranodular behaviour for a specific differentiation among different kinds of neoformations. Using a gamma-camera on line with a computer data processing device, sequential scintiscans were recorded for the first 20-30 min after i.v. administration of 15-20 μCi/kg of radiothallium; delayed sequences were taken at 40-60 min if intranodular uptake appeared. A quantitative appraisal was made of the differential 201 Tl uptake-ratio between nodule and healthy thyroid tissue (density-index) and the multiparameter analysis of thyroid time/activity curves generated on the relative regions of interest (ROIs). This computerized study, in 120 out of 293 patients submitted to this radiothallium test, has shown a) diagnostic agreement between clinical-histological and radioisotopic findings in 76 out of 79 colloid-cystic or degenerative neoformations, in all 16 malignant and in 23 out of 25 hyperplastic benign nodules; b) significant statistical difference of the density-index in solid versus cystic but not between benign and malignant nodules; c) different 201 Tl kinetics behaviour in different kinds of solid thyroid lesions with a satisfactory statistical difference of the radiothallium nodular dissappearance-index. (orig.) [de

  6. Differential diagnosis of thyroid diseases with 131I and 201TlCl scintigraphy

    International Nuclear Information System (INIS)

    Kumano, Machiko; Ishida, Osamu

    1979-01-01

    Scintigraphic study with 131 I and 201 TlCl was performed on the differential diagnosis of various kinds of thyroid disease. When thyroid nodules are cold by scintigraphy with 131 I and hot with 201 TlCl, the lesions were proved to be solid tumor, that is, mostly follicular adenoma and carcinoma, and also most probably chronic thyroiditis. Accumulation of 201 TlCl, however, is not observed in cystic lesions, and is very high with high frequency in metastatic lesion of the lymph nodes as well as the thyroid cancer, especially in well differentiated follicular carcinoma. Therefore 201 TlCl was very useful to confirm the metastatic tumors from the thyroid cancer. These features in accumulation of 131 I and 201 TlCl in thyroid disease suggest the imaging technique with 201 TlCl combined with 131 I seem to provide more pathological information on the thyroid and metastatic lesions. (author)

  7. Super-ionic conductivity in (1D) nanofibrous TlGaTe2

    International Nuclear Information System (INIS)

    Sardarly, R.M.; Samedov, O.A.; Abdullaev, A.P.; Salmanov, F.T.; Urbanovic, A.; Garet, F.; Coutaz, J.-L.

    2010-01-01

    Full text : Nanodimension topologic-disorder materials constitute an important feature in the development of modern electronics. Among such materials, TlGaTe 2 is a p-type semiconductor with a nanofibrous structure Ga 3 +Te 2 - 2 groups form chains extending along the c-axis of the material. These negatively charged chains are bonded together by Tl+ ions. The resulting tetragonal lattice is characterized by a 18 D4h group symmetry. Recently, much attention has been paid to systems that behave as if they had less than 3 spatial dimensions. Such materials are often called quasi-one-dimensional (1D) nanorods, nanofibrous or nanochains. It was already studied the temperature dependence of conductivity σ (T) and current-voltage (I-V) characteristics of TlGaTe 2 . In the ohmic region of the I -V curve, σ (T) exhibits a behavior typical of hopping conductivity, which can be modeled in the framework of the Mott approximation. Moreover, it was determined the values of the density of localized states, the activation energy, the hop lengths, and the difference between the energies of states and the concentration of deep traps. The abrupt variation of the I-V curve is ascribed to the Pool-Frenkel thermal-field effect, which allows to obtain the concentration of ionized centers, the free-path lengths, the Frenkel coefficients and the shape of the potential well of TlGaTe 2 . For T>300 K, TlGaTe 2 crystals present interesting nonlinear electrical behaviors, such as switching effects and a negative-differential-resistance (NDR) region in their S-type I-V characteristics. In the NDR region, self-excited oscillations of the voltage were also observed. Here, it was investigated the temperature dependence of TlGaTe 2 crystals conductivity σ (T) in two experimental geometries, i.e. parallel and perpendicularly to the tetragonal c-axis of the crystal. The observed sharp increase of TlGaTe 2 conductivity results from a strong change of the number of the high-mobility ions. The

  8. Abnormal 201Tl limb scan due to unilateral tremor

    International Nuclear Information System (INIS)

    Simons, M.; Schelstraete, K.; Bratzlavsky, M.

    1982-01-01

    A abnormal intra- and interextremity distribution pattern on 201 Tl was observed on the limb scan of a patient with a unilateral tremor. This is ascribed to the increased blood flow in the muscles responsible for the tremor. The suggestion is made that the existence of tremor should be considered as a possible explanation for unexpected abnormalities on 201 Tl limb scintigrams

  9. Substitution of indium for chromium in TlIn5−xCrxSe8: crystal structure of TlIn4.811(5Cr0.189(5Se8

    Directory of Open Access Journals (Sweden)

    Robin Lefèvre

    2017-04-01

    Full Text Available The new thallium penta(indium/chromium octaselenide, TlIn4.811(5Cr0.189(5Se8, has been synthesized by solid-state reaction. It crystallizes isotypically with TlIn5Se8 in the space group C2/m. Although the two Tl positions are disordered and only partially occupied, no Tl deficiency was observed. The insertion of chromium in the structure has been confirmed by EDS analysis. Chromium substitutes indium exclusively at one of three In sites, viz. at one of the positions with site symmetry 2/m (Wyckoff position 2a. In the crystal structure, edge-sharing InSe6 octahedra, and (In,CrSe6 octahedra and InSe4 tetrahedra make up two types of columns that are linked into a framework in which two different types of channels parallel to [010] are present. The Tl atoms are located in the larger of the channels, whereas the other, smaller channel remains unoccupied.

  10. Self-trapping nature of Tl nanoclusters on the Si(111)-7x7 surface

    International Nuclear Information System (INIS)

    Hwang, C G; Kim, N D; Lee, G; Shin, S Y; Kim, J S; Chung, J W

    2008-01-01

    We have studied properties of thallium (Tl) nanoclusters formed on the Si(111)-7x7 surface at room temperature (RT) by utilizing photoemission spectroscopy (PES) and high-resolution electron-energy-loss spectroscopy (HREELS) combined with first principles calculations. Our PES data reveal that the surface states stemming from the Si substrate remain quite inert with Tl adsorption producing no Tl-induced state until saturation at Tl coverage θ=0.21 monolayers. Such a behavior, in sharp contrast with the extremely reactive surface states upon the formation of Na or Li nanoclusters, together with the presence of a unique Tl-induced loss peak in HREELS spectra suggests no strong Si-Tl bonding, and is well understood in terms of gradual filling of Si dangling bonds with increasing θ. Our calculation further indicates the presence of several metastable atomic structures of Tl nanoclusters at RT rapidly transforming from one to another faster than 10 10 flippings per second. We thus conclude that the highly mobile Tl atoms form self-trapped nanoclusters within the attractive basins of the Si substrate at RT with several metastable phases. The mobile and multi-phased nature of Tl nanoclusters not only accounts for all the existing experimental observations available at present, but also provides an example of self-trapping of atoms in a nanometre-scale region

  11. Recovery of 201Tl by ion exchange chromatography from proton bombarded thallium cyclotron targets

    International Nuclear Information System (INIS)

    Walt, T.N. van der; Naidoo, C.

    2000-01-01

    A method based on ion exchange chromatography is presented for the recovery of 201 Tl and its precursor 201 Pb from proton bombarded natural thallium cyclotron targets. After bombardment the target is dissolved in diluted nitric acid. Water, hydrazine and ammonium acetate are added to the solution and the lead radioisotopes separated from the thallium by cation exchange chromatography on a Bio-Rex 70 column. The sorbed lead radioisotopes are eluted with dilute nitric acid and the separation repeated on a second Bio-Rex 70 column. After elution of the remaining thallium the column is left for 32 hours and the 201 Tl formed by decay of 201 Pb is eluted with an ammonium acetate solution. The 201 Tl eluate is acidified with a HNO 3 -HBr-Br 2 mixture and the resulting solution is passed through an AG MP-1 anion exchanger column to remove any remaining lead isotopes. The 201 Tl is eluted with a hydrazine solution, the eluate evaporated to dryness and the 201 Tl finally dissolved in an appropriate solution to produce a 201 TlCl solution suitable for medical use. A high quality 201 Tl product is obtained containing ≤ 0.1 μg of Tl/mCi (37 MBq) 201 Tl. The radionuclidic impurities are less than the maximum values specified by the US Pharmacopoeia and the British Pharmacopoeia. (orig.)

  12. Application of the Monte Carlo method for the efficiency calibration of CsI and NaI detectors for gamma-ray measurements from terrestrial samples

    International Nuclear Information System (INIS)

    Baccouche, S.; Al-Azmi, D.; Karunakara, N.; Trabelsi, A.

    2012-01-01

    Gamma-ray measurements in terrestrial/environmental samples require the use of high efficient detectors because of the low level of the radionuclide activity concentrations in the samples; thus scintillators are suitable for this purpose. Two scintillation detectors were studied in this work; CsI(Tl) and NaI(Tl) with identical size for measurement of terrestrial samples for performance study. This work describes a Monte Carlo method for making the full-energy efficiency calibration curves for both detectors using gamma-ray energies associated with the decay of naturally occurring radionuclides 137 Cs (661 keV), 40 K (1460 keV), 238 U ( 214 Bi, 1764 keV) and 232 Th ( 208 Tl, 2614 keV), which are found in terrestrial samples. The magnitude of the coincidence summing effect occurring for the 2614 keV emission of 208 Tl is assessed by simulation. The method provides an efficient tool to make the full-energy efficiency calibration curve for scintillation detectors for any samples geometry and volume in order to determine accurate activity concentrations in terrestrial samples. - Highlights: ► CsI (Tl) and NaI (Tl) detectors were studied for the measurement of terrestrial samples. ► Monte Carlo method was used for efficiency calibration using natural gamma emitting terrestrial radionuclides. ► The coincidence summing effect occurring for the 2614 keV emission of 208 Tl is assessed by simulation.

  13. A study of the effect of Al2O3 reflector on response function of NaI(Tl) detector

    International Nuclear Information System (INIS)

    Tam, Hoang Duc; Chuong, Huynh Dinh; Thanh, Tran Thien; Van Tao, Chau

    2016-01-01

    This study aims to assess the effect of Al 2 O 3 reflector surrounding the NaI(Tl) crystal on the detector response function, based on Monte Carlo simulation, which can verify the precise model of the NaI(Tl) detector. The method used in determining the suitable thickness of Al 2 O 3 reflector is to compare the calculated and experimental values of full-energy peak efficiency. The results show that the Al 2 O 3 reflector should have a thickness of 0.8–1.2 mm for the maximum deviation between the experimental and simulated efficiency of 3.2% at all concerning energies. In addition, the obtained results are in good agreement with the response function of simulation and experimental spectra. - Highlights: • The study was conducted to verify the model of Monte Carlo simulation. • The effect of Al 2 O 3 reflector on the detector response function was investigated. • The optimum thickness of Al 2 O 3 reflector is suggested.

  14. Study on effects of gamma-ray irradiation on TlBr semiconductor detectors

    International Nuclear Information System (INIS)

    Matsumura, Motohiro; Watanabe, Kenichi; Yamazaki, Atsushi; Uritani, Akira; Kimura, Norihisa; Nagano, Nobumichi; Hitomi, Keitaro

    2016-01-01

    Radiation hardness of thallium bromide (TlBr) semiconductor detectors to 60 Co gamma-ray irradiation was evaluated. The energy spectra and μτ products of electrons were measured to evaluate the irradiation effects. No significant degradation of spectroscopic performance of the TlBr detector for 137 Cs gamma-rays was observed up to 45 kGy irradiation. Although the μτ products of electrons in the TlBr detector slightly decreased, position of the photo-peak was stable without significant degradation after the gamma-ray irradiation. We confirmed that the TlBr semiconductor detector has a high tolerance for gamma-ray irradiation at least up to 45 kGy. (author)

  15. Diagnostic and corrective procedures for TL analysis using the pre-dose technique

    International Nuclear Information System (INIS)

    Haskell, E.H.

    1985-01-01

    The high sensitivity of the pre-dose TL technique using fired quartz grains with relatively low doses makes it the only TL technique that is generally suitable for retrospective environmental dosimetry. The use of this technique for dose measurements of less than 0.2 Gy has been the focus of research at the Utah laboratory, while the extension of the useful range of the pre-dose technique to doses in excess of 5 Gy has been the aim of the Durham laboratory. Certain characteristics of the pre-dose phenomenon, if not properly diagnosed, can lead to erroneous dose estimates at both extremes. This paper describes the procedures used at both laboratories to diagnose such problems and recently developed methods for their circumvention. (author)

  16. Improvements in the Tl dosimetry for Radiotherapy; Mejoras en la dosimetria Tl para Radioterapia

    Energy Technology Data Exchange (ETDEWEB)

    Bustos, S.; Velez, G.; Rubio, M. [CEPROCOR. Arenales 230 Juniors Cordoba 5000 (Argentina)

    1998-12-31

    The thermoluminescent dosimetry (TLD) in vivo has been demonstrated to be one of the most reliable for the control of radiotherapeutic treatments, but the delay in the response is the main disadvantage in its applicability. In this work are presented important improvements and it is demonstrated that maintaining the accuracy and reliability of the technique, it is possible to accelerate the response times at a few hours. To realize this work is utilized a lecturer Harshaw 4000, dosemeters LiF-TLD-100 chips (3.1 x 3.1 x 0.89 mm{sup 3}) and rods (1 x 1 x 6 mm{sup 3}). With the implementation of a glow curve analysis program developed in CIEMAT, its obtained a Tl peaks separation in such manner rapid and accurate, by that the thermal treatment of dosemeters may be reduced at one unique annealing pre-irradiation for 1 hr at 400 Centigrade. It is realized a periodical and individual calibration of the TLD and a study of the factors which influencing the ratio Tl signal-dose as linearity, correction by energy, directional response and pride of Tl signal. the results of this study are introducing in a calculation list specially designed and which allows to obtain absorbed dose by TLD starting of the dates (dosimetric peaks area) which appear of the glow curves analysis. The dose is obtained with an accuracy less than 5 %. The dosemeters already irradiated (in vivo) are analysed and informed in only four hours, allowing a greater control of the treatment and a correction of the possible errors for the next session, still in bi fractional treatments. The method implemented results thus accurate, rapid and reliable. (Author)

  17. Bonding and M?ssbauer Isomer Shifts in (Tl,Pb) - 1223 Cuprate

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    By using the chemical bond theory of dielectric description,the chemical bond parameters of (Tl,Pb) - 1223 was calculated.The results show that the Sr-O,Tl-O,and Ca-O types of bond have higher ionic character and the Cu-O types of bond have more covalent character.M?ssbauer isomer shifts of 57Fe and 119Sn doped in (Tl,Pb) -1223 were calculated by using the chemical environmental factor,he,defined by covalency and electronic polarizability.Four valence state tin and three valence iron sites were identified in 57Fe,and 119Sn doped (Tl,Pb) -1223 superconductor.We conclude that all of the Fe atoms substitute the Cu at square planar Cu (1) site,whereas Sn prefers to substitute the square pyramidal Cu (2) site.

  18. AG, TL, and IRSL dosimetric properties in X-ray irradiated HPHT diamond crystals

    Energy Technology Data Exchange (ETDEWEB)

    Gil-Tolano, M.I. [Programa de Posgrado, Departamento de Investigacion en Fisica, Universidad de Sonora, A. P. 5-088, Hermosillo, Sonora, 83190, Mexico (Mexico); Melendrez, R.; Lancheros-Olmos, J.C.; Soto-Puebla, D.; Chernov, V.; Pedroza-Montero, M.; Barboza-Flores, M. [Departamento de Investigacion en Fisica, Universidad de Sonora, A. P. 5-088, Hermosillo, Sonora, 83190, Mexico (Mexico); Castaneda, B. [Departamento de Fisica, Universidad de Sonora, Blvd. Luis Encinas y Rosales S/N, Hermosillo, Sonora, 83000, Mexico (Mexico)

    2014-10-15

    HPHT diamonds have been studied for several years for their potential in different applications. In previous studies it has been found that the thermoluminescence (TL) glow curves of ''as-grown'' HPHT diamonds are non-reproducible. In this work, we study the afterglow (AG), thermoluminescent (TL), and optically stimulated luminescence (OSL) response of commercial samples of synthetic HPHT type-Ib diamond crystals exposed to X-ray irradiation (0.75 mA, 35 kV) at a dose rate of 0.624 Gy/s, after a high gamma ({sup 60}Co) dose irradiation of 500 kGy followed by a thermal treatment at 1073 K for 1 h in nitrogen atmosphere. Deconvolution of the TL glow curves shows four peaks, located around 379, 509, 561, and 609 K. The crystals exhibit evident AG recorded for 300 s immediately after X-ray irradiation, due to the thermal emptying of the traps responsible for the low-temperature TL peaks (below 400 K). The stimulation of irradiated crystals with 870-nm light, creates pronounced OSL and destroys all TL peaks with the exception of the high-temperature peak at 609 K. The dose responses of the integrated AG, TL, and OSL are linear in the range of 0.6-5 Gy and saturated at higher doses. The reproducibility of AG, TL, and OSL measurements is about 5%. The fading in the first hour of storage in dark conditions at RT of TL signal of HPHT diamond is mainly associated to the emptying of the traps responsible for the 379-K TL peaks. (copyright 2014 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  19. Preparation of biaxially oriented TlCu-1234 thin films

    CERN Document Server

    Khan, N A; Tateai, F; Kojima, T; Ishida, K; Terada, N; Ihara, H

    1999-01-01

    The single phase of TlCu-1234 superconductor thin films is prepared for the first time by the amorphous phase epitaxy (APE) method, which is thallium treatment of sputtered amorphous phase at 900 degrees C for 1 h. The amorphous $9 phase is prepared by sputtering from the stoichiometric target composition CuBa/sub 2/Ca/sub 3/Cu/sub 4/O/sub 12-y/. The films on the SrTiO/sub 3/ substrate are aligned biaxially after the thallium treatment. Highly reproducible $9 TlCu-1234 films are prepared by this method. The XRD reflected a predominant single phase with the c-axis lattice constant of 18.74 AA. This lattice constant value is in between that of Cu-1234 (17.99 AA) and Tl-1234 (19.11 AA) . The $9 pole figure measurements of (103) reflection of the films showed a-axis-oriented crystals with Delta phi =0.8 degrees . The composition of the films after energy dispersive X-ray (EDX) measurements is Tl/sub 0.8/Cu/sub 0.2/Ba/sub $9 2/Ca/sub 3/Cu/sub 4/O /sub 12-y/. From the resistivity measurements, the T/sub c/ is 113 K...

  20. Determination of kinetic parameters in Tl dosemeters of LiF: Mg, Cu, P + PTFE developed in the ININ; Determinacion de parametros cineticos en dosimetros Tl de LiF: Mg, Cu, P + PTFE desarrollados en el ININ

    Energy Technology Data Exchange (ETDEWEB)

    Basurto G, B.S

    2002-07-01

    The objective of this work, is the one of determining the kinetic parameters of the dosemeter of LiF: Mg, Cu, P + Ptfe; starting from the curves Tl obtained at being irradiated with alpha radiation ({alpha}), beta ({beta}) and gamma ({gamma}). As like to compare its sensitivity with each radiation type, considering the sensitivity of the TLD-100 as the unit. In the Chapter 1, the fundamental structure of the matter is described, making emphasis in the different radiation types, and their interaction with this. In the Chapter 2, the units are described but used in the dosimetry of the radiation. In the Chapter 3, the basic concepts of the phenomenon of Tl are described and those are explained characteristic of the deconvolution method to determine the kinetics of the one phenomenon. In the Chapter 4, the methodology is detailed that was used in the elaboration of this thesis work, describing the material Tl that were considered like reference, as well as the sources of ionizing radiation, with those that the dosemeters were irradiated and the equipment in the one that the curves Tl was obtained. Reference is made to the software used to carry out the deconvolution of the curves Tl that were obtained in the one experimental development. In the Chapter 5, the obtained results of this study are presented, showing the tables of homogenization of dosemeters and the reading of the same one; they are observed the curves Tl obtained to different radiation doses (alpha, beta and gamma), the intensity Tl in function of the dose. Also they are tabulated, the obtained results in the kinetic parameters of the three different study materials (TLD-100H, USA; TLD-100, USA and LiF: Mg, Cu, P + Ptfe developed in the l.N.l.N). They are analyzed shortly for each material Tl their sensitivity to the ionizing radiation as well as their kinetic parameters. The obtained results showed that the Tl dosemeters of LiF: Mg,Cu,P + Ptfe, they presented a bigger sensitivity that the TLD-100 when

  1. Nuclear resonance fluorescence of {sup 203,205}Tl

    Energy Technology Data Exchange (ETDEWEB)

    Pfeifer, Fabian; Fritzsche, Matthias; Pietralla, Norbert; Savran, Deniz; Weller, Henry; Zweidinger, Markus [Institut fuer Kernphysik, Technische Universitaet, Darmstadt (Germany); Rusev, Gencho; Tonchev, Anton P.; Tornow, Werner [Triangle Universities Nuclear Laboratory, Duke University, Durham (United States); Zilges, Andreas [Institut fuer Kernphysik, Universitaet Koeln (Germany)

    2009-07-01

    In order to investigate the dipole strength distribution in Thalium isotopes we have studied Nuclear Resonance Fluorescence of a sample composed of natural Thallium (consisting of 30% {sup 203}Tl and 70% {sup 205}Tl). Unpolarized bremsstrahlung with photo energies up to 7.5 MeV was used at the High Intensity Photon Setup (HIPS) at S-DALINAC at the IKP Darmstadt. 24 fluorescent {gamma}-ray transitions were observed, 19 of them for the first time. For the assignment of the polarity of two prominent {gamma}-ray transitions, one at 4.7 MeV and one at 4.9 MeV, the polarized photon beam of the High Intensity {gamma}-ray Source (HI{gamma}S) at Duke University was used. The experiment at HI{gamma}S revealed the existence of a photo-excited state of {sup 205}Tl at an excitation energy of 4.971 MeV that exhibits a transition to the first excited state at 203 keV.

  2. Preparation and biodistribution of [201Tl](III)vancomycin complex in normal rats

    International Nuclear Information System (INIS)

    Jalilian, A.R.; Hosseini, M.A.; Karimian, A.; Saddadi, F.; Sadeghi, M.

    2006-01-01

    Thallium-201 (T 1/2 = 3.04 days) in Tl + form was converted to Tl 3+ cation in presence of O 3 in 6 M HCl controlled by RTLC/gel electrophoresis methods. The final evaporated activity was reacted with vancomycin (VAN) in water to yield [ 201 Tl](III)VAN. The best results were obtained at room temperature in water after 30 min with a radiochemical yield >99%, after mixing the reactants followed by SPE purification using Si Sep-Pak. The studies showed that thallic ion is mostly incorporated into vancomycin with a radiochemical purity of more than 98 ± 1% by RTLC. A specific activity of about 4.14·10 10 Bq/mmol was obtained. Radiochemical purity and stability of 201 Tl-VAN in the preparation and in presence of human serum was determined up to 5.5 days. Biodistribution study of 201 Tl(III)-vancomycin in normal rats was performed up to 52 h. (authors)

  3. Evaluation of polymer-coated CsI:Tl as an alpha/beta pulse shape discriminating flow-cell

    International Nuclear Information System (INIS)

    Branton, S.D.; Fjeld, R.A.; DeVol, T.A.

    1996-01-01

    A pulse shape discriminating flow-cell radiation detection system constructed with polymer coated CsI:Tl was evaluated for simultaneous gross alpha/gross beta quantification. The CsI:TI scintillator was crushed and sieved to 63-90 μm particle size and microencapsulated with Parylene C to reduce its rate of dissolution. Averaged over the first hour of use, the pulse shape discrimination figure-of-merit was 1.4 and the detection efficiencies were 64.9 ± 5.7 %, 52.5 ± 4.5 % and 4.5 ± 0.2 % for 233 U, 90 Sr/ 90 Y and 14 C , respectively. The typical background count rate in the alpha and beta pulse shape window was 0.17 and 0.004 cps, respectively. The resultant minimum detectable activity for a 30 second count time was calculated to be 0.19 ± 0.01 Bq, 0.9 ± 0.1 Bq and 11.4 ± 0.6 Bq for 233 U, 90 Sr/ 90 Y and 14 C, respectively. Although the 3 μm thick microencapsulation reduced CsI:Tl dissolution, the detection efficiency declined by a factor of two after 4.8 hours while the pulse shape resolution degraded slightly

  4. Electronic band structure study of colossal magnetoresistance in Tl 2Mn 2O 7

    Science.gov (United States)

    Seo, D.-K.; Whangbo, M.-H.; Subramanian, M. A.

    1997-02-01

    The electronic structure of Tl 2Mn 2O 7 was examined by performing tight binding band calculations. The overlap between the Mn t 2g- and Tl 6 s-block bands results in a partial filling of the Tl 6 s-block bands. The associated Fermi surface consists of 12 cigar-shape electron pockets with each electron pocket about {1}/{1000} of the first Brillouin zone in size. The Tl 6 s-block bands have orbital contributions from the Mn atoms, and the carrier density is very low. These are important for the occurrence of a colossal magnetoresistance in Tl 2Mn 2O 7.

  5. Myocardial uptake of iodinated free fatty acids and 201Tl in experimental ischemia

    International Nuclear Information System (INIS)

    Westera, G.; Wall, E.E. van der; Visser, F.C.; Scholtalbers, A.S.; Eenige, M.J. van; Roos, J.P.

    1984-01-01

    In an experimental study, we evaluated the uptake of ( 131 I)-17-iodo heptadecanoic acid ( 131 I-HDA), ( 125 I)-15-4 (4-iodophenyl) pentadecanoic acid ( 125 I-PPA) and thallium-201 ( 201 Tl) in the dog heart. Twenty dogs were studied and divided into 3 groups: in group A, 10 dogs (4 normal, 6 with coronary artery occlusion) were studied with 131 I-HDA and 201 Tl; in group B, 5 dogs (with occlusion) received 125 I-PPA and 201 Tl; and in group C, 5 dogs (with occlusion) were studied with 125 I-PPA and 131 I-HDA. Two min after administration of the compounds the hearts were excised and stored in formaldehyde. After sectioning of the left ventricle, total uptake was counted and expressed in percentage of injected dose. Uptake in the normal myocardium (group A) was 4.2+-0.6% for 131 I-HDA and 4.6+-0.7% for 201 Tl; in the occluded dog hearts (group A) we measured values of 2.6+-0.4% for 131 I-HDA (p 201 Tl (p 131 I-HDA, 125 I-PPA and 201 Tl in groups B and C was not significantly different: group B, 125 I-PPA 2.8+-0.8% and 201 Tl 2.5+-0.5%; group C, 125 I-PPA 1.9+-0.7% and 131 I-HDA 1.6+-0.6%. Moreover, regional distribution of both iodinated fatty acids was quite comparable with the distribution of 201 Tl. We conclude that 131 I-HDA and 125 I-PPA show similar uptake as 201 Tl and are distributed according to coronary artery perfusion, which underscores their value as myocardial imaging agents. (orig.) [de

  6. Coronary spasm: 201Tl scintiscanning following pharmacological provocation

    International Nuclear Information System (INIS)

    Montz, R.; Mathey, D.; Bleifeld, W.; Hamburg Univ.

    1981-01-01

    According to the authors' experience so far, 201 Tl myocardial scintiscanning is a sufficiently sensitive non-invasive method for detection of coronary vasospasm provoked by ergotamine administration. Mild incomplete and asymptotic forms of coronary vasospasm were detected by scintiscanning. Indications for myocardial scintiscanning of ergotamine-provoked vasospasm are: Cases of angina pectoris at rest in which electrocardiograms during spasm are not available; elleviated symptoms after nitroglycerine administration; exercise electrocardiograms without any sign of ischaemia; negative results of exercise 201 Tl myocardial scintiscanning. (orig.) [de

  7. Thermoluminescence (TL) in the identification of irradiated food

    International Nuclear Information System (INIS)

    Luthra, J.M.

    1992-01-01

    Due to progressive expansion of commercial food irradiation in recent years, the interest in detecting whether a food has been irradiated or not is growing fast and research in several methods for identification of various irradiated food stuffs is the order of the day. TL has emerged as one of the most promising tool for distinguishing between irradiated and unirradiated food. Advantages of TL method over other physical methods, its application to various foods, limitation and present state of art are discussed.(author). 9 refs., 3 tabs

  8. Tl response of LiF:Mg, Cu, P + PTFE to Am-Be neutrons

    International Nuclear Information System (INIS)

    Gonzalez M, P.R.

    2000-01-01

    In different laboratories of the world it is followed the research about development of new Tl materials, whose main characteristics should be their equivalence with the tissue and their high sensibility to any type of radiation. The study consists in to measure the Tl peak intensity which TLD-100 presents at being irradiated with neutrons and that appears over 250 Centigrade, for compare it with the Tl intensity of the LiF: Mg, Cu, P + PTFE dosemeters. However, not all dosemeters of the same group show the interesting peak, by this only can be the total Tl intensity of dosemeters studied. In the ININ dosemeters development laboratory, we have developed a Tl material of lithium fluoride activated with magnesium, copper and phosphorus (LiF: Mg, Cu, P) that in polycrystalline powder form is almost 35 times more sensitive than the TLD-100 commercial dosemeter of Harshaw/Filtrol, USA. With the use of polytetrafluorethylene (PTFE) and with the above described Tl material, it has been possible to obtain dosemeters in pellet form of LiF: Mg, Cu, P + PTFE. (Author)

  9. Positive Selection of γδ CTL by TL Antigen Expressed in the Thymus

    Science.gov (United States)

    Tsujimura, Kunio; Takahashi, Toshitada; Morita, Akimichi; Hasegawa-Nishiwaki, Hitomi; Iwase, Shigeru; Obata, Yuichi

    1996-01-01

    To elucidate the function of the mouse TL antigen in the thymus, we have derived two TL transgenic mouse strains by introducing Tla a -3 of A strain origin with its own promoter onto a C3H background with no expression of TL in the thymus. These transgenic mouse strains, both of which express high levels of Tlaa-3-TL antigen in their thymus, were analyzed for their T cell function with emphasis on cytotoxic T lymphocyte (CTL) generation. A T cell response against TL was induced in Tg.Tlaa-3-1, Tg.Tlaa-3-2, and control C3H mice by skin grafts from H-2K b/T3 b transgenic mice, Tg.Con.3-1, expressing T3b-TL ubiquitously. Spleen cells from mice that had rejected the T3b-TL positive skin grafts were restimulated in vitro with Tg.Con.3-1 irradiated spleen cells. In mixed lymphocyte cultures (MLC), approximately 20% and 15% of Thy-1+ T cells derived from Tg.Tlaa-3-1 and Tg.Tlaa-3-2, respectively, expressed TCRγδ, whereas almost all those from C3H expressed TCRαβ. The MLC from Tg.Tlaa-3-2 and C3H demonstrated high CTL activity against TL, while those from Tg.Tlaa-3-1 had little or none. The generation of γδ CTL recognizing TL in Tg.Tlaa-3-2, but not C3H mice, was confirmed by the establishment of CTL clones. A total of 14 γδ CTL clones were established from Tg.Tlaa-3-2, whereas none were obtained from C3H. Of the 14 γδ CTL clones, 8 were CD8+ and 6 were CD4−CD8− double negative. The CTL activity of all these clones was TL specific and inhibited by anti-TL, but not by anti-H-2 antibodies, demonstrating that they recognize TL directly without antigen presentation by H-2. The CTL activity was blocked by antibodies to TCRγδ and CD3, and also by antibodies to CD8α and CD8β in CD8+ clones, showing that the activity was mediated by TCRγδ and coreceptors. The thymic origin of these γδ CTL clones was indicated by the expression of Thy-1 and Ly-1 (CD5), and also CD8αβ heterodimers in CD8+ clones on their surfaces and by the usage of TCR Vγ4 chains in 12 of

  10. Study of 207Tl126 Produced in Deep-Inelastic Reactions

    Directory of Open Access Journals (Sweden)

    Wilson E.

    2014-03-01

    Full Text Available Deep-inelastic collisions of a 208Pb beam on a 208Pb target were performed using the ATLAS accelerator at Argonne National Laboratory. The Gammasphere detector array was used for the detection of prompt and delayed gamma-rays of the reaction products.207Tl is one proton away from the 208Pb doubly-magic nucleus. Its low-energy level structure is dominated by the single proton-hole states πs1/2−1, πd3/2−1 and πh11/2−1. The 11/2− state is isomeric with T1/2 = 1.33(11 s. The reaction partner of 207Tl is 209Bi, which has arelatively well established level scheme compared to 207Tl. Cross-coincidences between these two nuclei were used to confirm or establish levels above the 11/2− isomeric state in 207Tl. These states are obtained via breaking of the neutron core. Angular correlation analysis was performed on known transitions in 208Pb, proving the applicability of this method for multipolarity assignment.

  11. Application of the Monte Carlo method for the efficiency calibration of CsI and NaI detectors for gamma-ray measurements from terrestrial samples

    Energy Technology Data Exchange (ETDEWEB)

    Baccouche, S., E-mail: souad.baccouche@cnstn.rnrt.tn [UR-MDTN, National Center for Nuclear Sciences and Technology, Technopole Sidi Thabet, 2020 Sidi Thabet (Tunisia); Al-Azmi, D., E-mail: ds.alazmi@paaet.edu.kw [Department of Applied Sciences, College of Technological Studies, Public Authority for Applied Education and Training, Shuwaikh, P.O. Box 42325, Code 70654 (Kuwait); Karunakara, N., E-mail: karunakara_n@yahoo.com [University Science Instrumentation Centre, Mangalore University, Mangalagangotri 574199 (India); Trabelsi, A., E-mail: adel.trabelsi@fst.rnu.tn [UR-MDTN, National Center for Nuclear Sciences and Technology, Technopole Sidi Thabet, 2020 Sidi Thabet (Tunisia); UR-UPNHE, Faculty of Sciences of Tunis, El-Manar University, 2092 Tunis (Tunisia)

    2012-01-15

    Gamma-ray measurements in terrestrial/environmental samples require the use of high efficient detectors because of the low level of the radionuclide activity concentrations in the samples; thus scintillators are suitable for this purpose. Two scintillation detectors were studied in this work; CsI(Tl) and NaI(Tl) with identical size for measurement of terrestrial samples for performance study. This work describes a Monte Carlo method for making the full-energy efficiency calibration curves for both detectors using gamma-ray energies associated with the decay of naturally occurring radionuclides {sup 137}Cs (661 keV), {sup 40}K (1460 keV), {sup 238}U ({sup 214}Bi, 1764 keV) and {sup 232}Th ({sup 208}Tl, 2614 keV), which are found in terrestrial samples. The magnitude of the coincidence summing effect occurring for the 2614 keV emission of {sup 208}Tl is assessed by simulation. The method provides an efficient tool to make the full-energy efficiency calibration curve for scintillation detectors for any samples geometry and volume in order to determine accurate activity concentrations in terrestrial samples. - Highlights: Black-Right-Pointing-Pointer CsI (Tl) and NaI (Tl) detectors were studied for the measurement of terrestrial samples. Black-Right-Pointing-Pointer Monte Carlo method was used for efficiency calibration using natural gamma emitting terrestrial radionuclides. Black-Right-Pointing-Pointer The coincidence summing effect occurring for the 2614 keV emission of {sup 208}Tl is assessed by simulation.

  12. Antiferromagnetism Induced in the Vortex Core of Tl2Ba2CuO6++δ Probed by Spatially-Resolved 205Tl-NMR

    International Nuclear Information System (INIS)

    Kumagai, K.; Kakuyanagi, K.; Matsuda, Y.; Hasegawa, T.

    2003-01-01

    Magnetism in the vortex core state has been studied by spatially-resolved NMR. The nuclear spin lattice relaxation rate T 1 -1 of 205 Tl in nearly optimal-doped Tl 2 Ba 2 CuO 6+ δ (T c =85 K) is significantly enhanced in the vortex core region. The NMR results suggest that the suppression of the d-wave superconducting order parameter in the vortex core leads to the nucleation of islands with local antiferromagnetic (AF) order. (author)

  13. Synthesis and properties of Tl endash Ba endash Ca endash Cu endash O superconductors

    International Nuclear Information System (INIS)

    Siegal, M.P.; Venturini, E.L.; Morosin, B.; Aselage, T.L.

    1997-01-01

    We review the synthesis methods and properties of single crystal, powder and thin film TlBaCaCuO high-temperature superconducting (Tl-HTS) materials. With transition temperatures ≥100K for several compounds, Tl-HTS materials present real opportunities for applications above 77 K. Experiments using (1) single crystals: determined precise structural parameters and identified the complex Tl 1+ -Tl 3+ equilibrium model; (2) powders: studied the complex thermodynamic phase diagram; and (3) epitaxial films: have studied fundamental properties such as electron pair symmetry and the effect of controlled extrinsic defects on flux pinning strength, as well as providing the large-area surfaces required for device applications. copyright 1997 Materials Research Society

  14. Novel laser-processed CsI:Tl detector for SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Sabet, H., E-mail: hsabet@mgh.harvard.edu; Uzun-Ozsahin, D.; El-Fakhri, G. [Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts 02129 (United States); Bläckberg, L. [Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts 02129 and Department of Physics and Astronomy, Uppsala University, Uppsala 75120 (Sweden)

    2016-05-15

    Purpose: The aim of this work is to demonstrate the feasibility of a novel technique for fabrication of high spatial resolution CsI:Tl scintillation detectors for single photon emission computed tomography systems. Methods: The scintillators are fabricated using laser-induced optical barriers technique to create optical microstructures (or optical barriers) inside the CsI:Tl crystal bulk. The laser-processed CsI:Tl crystals are 3, 5, and 10 mm in thickness. In this work, the authors focus on the simplest pattern of optical barriers in that the barriers are created in the crystal bulk to form pixel-like patterns resembling mechanically pixelated scintillators. The monolithic CsI:Tl scintillator samples are fabricated with optical barrier patterns with 1.0 × 1.0 mm{sup 2} and 0.625 × 0.625 mm{sup 2} pixels. Experiments were conducted to characterize the fabricated arrays in terms of pixel separation and energy resolution. A 4 × 4 array of multipixel photon counter was used to collect the scintillation light in all the experiments. Results: The process yield for fabricating the CsI:Tl arrays is 100% with processing time under 50 min. From the flood maps of the fabricated detectors exposed to 122 keV gammas, peak-to-valley (P/V) ratios of greater than 2.3 are calculated. The P/V values suggest that regardless of the crystal thickness, the pixels can be resolved. Conclusions: The results suggest that optical barriers can be considered as a robust alternative to mechanically pixelated arrays and can provide high spatial resolution while maintaining the sensitivity in a high-throughput and cost-effective manner.

  15. Novel laser-processed CsI:Tl detector for SPECT

    International Nuclear Information System (INIS)

    Sabet, H.; Uzun-Ozsahin, D.; El-Fakhri, G.; Bläckberg, L.

    2016-01-01

    Purpose: The aim of this work is to demonstrate the feasibility of a novel technique for fabrication of high spatial resolution CsI:Tl scintillation detectors for single photon emission computed tomography systems. Methods: The scintillators are fabricated using laser-induced optical barriers technique to create optical microstructures (or optical barriers) inside the CsI:Tl crystal bulk. The laser-processed CsI:Tl crystals are 3, 5, and 10 mm in thickness. In this work, the authors focus on the simplest pattern of optical barriers in that the barriers are created in the crystal bulk to form pixel-like patterns resembling mechanically pixelated scintillators. The monolithic CsI:Tl scintillator samples are fabricated with optical barrier patterns with 1.0 × 1.0 mm"2 and 0.625 × 0.625 mm"2 pixels. Experiments were conducted to characterize the fabricated arrays in terms of pixel separation and energy resolution. A 4 × 4 array of multipixel photon counter was used to collect the scintillation light in all the experiments. Results: The process yield for fabricating the CsI:Tl arrays is 100% with processing time under 50 min. From the flood maps of the fabricated detectors exposed to 122 keV gammas, peak-to-valley (P/V) ratios of greater than 2.3 are calculated. The P/V values suggest that regardless of the crystal thickness, the pixels can be resolved. Conclusions: The results suggest that optical barriers can be considered as a robust alternative to mechanically pixelated arrays and can provide high spatial resolution while maintaining the sensitivity in a high-throughput and cost-effective manner.

  16. TL, EPR and optical absorption in natural grossular crystal

    Energy Technology Data Exchange (ETDEWEB)

    Yauri, J.M. [Institute of Physics, University of Sao Paulo, Rua do Matao, Travessa R, 187, CEP 05508-900, Sao Paulo (Brazil); Department of Physics, University of San Agustin, Av. Independencia S/N, Arequipa (Peru); Cano, N.F. [Institute of Physics, University of Sao Paulo, Rua do Matao, Travessa R, 187, CEP 05508-900, Sao Paulo (Brazil)], E-mail: nilocano@dfn.if.usp.br; Watanabe, S. [Institute of Physics, University of Sao Paulo, Rua do Matao, Travessa R, 187, CEP 05508-900, Sao Paulo (Brazil)

    2008-10-15

    Grossular is one of six members of silicate Garnet group. Two samples GI and GII have been investigated concerning their luminescence thermally stimulated (TL). EPR and optical absorption and the measurements were carried out to find out whether or not same point defects are responsible for all three properties. Although X-rays diffraction analysis has shown that both GI and GII have practically the same crystal structure of a standard grossular crystal, they presented different behavior in many aspects. The TL glow curve shape, TL response to radiation dose, the effect of annealing at high temperatures before irradiation, the dependence of UV bleaching parameters on peak temperature, all of them differ going from GI to GII. The EPR signals around g=2.0 as well as at g=4.3 and 6.0 have much larger intensity in GI than in GII. Very high temperature (>800 deg. C) annealing causes large increase in the bulk background absorption in GI, however, only very little in GII. In the cases of EPR and optical absorption, the difference in their behavior can be attributed to Fe{sup 3+} ions; however, in the TL case one cannot and the cause was not found as yet.

  17. TL, EPR and optical absorption in natural grossular crystal

    International Nuclear Information System (INIS)

    Yauri, J.M.; Cano, N.F.; Watanabe, S.

    2008-01-01

    Grossular is one of six members of silicate Garnet group. Two samples GI and GII have been investigated concerning their luminescence thermally stimulated (TL). EPR and optical absorption and the measurements were carried out to find out whether or not same point defects are responsible for all three properties. Although X-rays diffraction analysis has shown that both GI and GII have practically the same crystal structure of a standard grossular crystal, they presented different behavior in many aspects. The TL glow curve shape, TL response to radiation dose, the effect of annealing at high temperatures before irradiation, the dependence of UV bleaching parameters on peak temperature, all of them differ going from GI to GII. The EPR signals around g=2.0 as well as at g=4.3 and 6.0 have much larger intensity in GI than in GII. Very high temperature (>800 deg. C) annealing causes large increase in the bulk background absorption in GI, however, only very little in GII. In the cases of EPR and optical absorption, the difference in their behavior can be attributed to Fe 3+ ions; however, in the TL case one cannot and the cause was not found as yet

  18. TL and ESR based identification of gamma-irradiated frozen fish using different hydrolysis techniques

    International Nuclear Information System (INIS)

    Ahn, Jae-Jun; Akram, Kashif; Shahbaz, Hafiz Muhammad; Kwon, Joong-Ho

    2014-01-01

    Frozen fish fillets (walleye Pollack and Japanese Spanish mackerel) were selected as samples for irradiation (0–10 kGy) detection trials using different hydrolysis methods. Photostimulated luminescence (PSL)-based screening analysis for gamma-irradiated frozen fillets showed low sensitivity due to limited silicate mineral contents on the samples. Same limitations were found in the thermoluminescence (TL) analysis on mineral samples isolated by density separation method. However, acid (HCl) and alkali (KOH) hydrolysis methods were effective in getting enough minerals to carry out TL analysis, which was reconfirmed through the normalization step by calculating the TL ratios (TL 1 /TL 2 ). For improved electron spin resonance (ESR) analysis, alkali and enzyme (alcalase) hydrolysis methods were compared in separating minute-bone fractions. The enzymatic method provided more clear radiation-specific hydroxyapatite radicals than that of the alkaline method. Different hydrolysis methods could extend the application of TL and ESR techniques in identifying the irradiation history of frozen fish fillets. - Highlights: • Irradiation has potential to improve hygienic quality of raw and processed seafood. • Detection of irradiated food is important to enforce the applied regulations. • Different techniques were compared to separate silicate minerals from frozen fish. • Limitations were observed in TL analysis on minerals isolated by density separation. • Hydrolysis methods provided more clear identification using TL and ESR techniques

  19. Performance of novel materials for radiation detection: Tl{sub 3}AsSe{sub 3}, TlGaSe{sub 2}, and Tl{sub 4}HgI{sub 6}

    Energy Technology Data Exchange (ETDEWEB)

    Kahler, D., E-mail: david.kahler@ngc.com [Northrop Grumman Corporation, ES-ATL, 1212 Winterson Road, Linthicum, MD 21090 (United States); Singh, N.B.; Knuteson, D.J.; Wagner, B.; Berghmans, A.; McLaughlin, S.; King, M.; Schwartz, K. [Northrop Grumman Corporation, ES-ATL, 1212 Winterson Road, Linthicum, MD 21090 (United States); Suhre, D.; Gotlieb, M. [DRS Scientific, 300 Oak Lake Road, New Kensington, PA 15068 (United States)

    2011-10-01

    In this paper we report on the electrical characteristics of three novel ternary compounds, Tl{sub 3}AsSe{sub 3} (TAS), TlGaSe{sub 2} (TGS), and Tl{sub 4}HgI{sub 6} (THI), pertaining to their use as radiation detectors. The details for growth and material characterization are not presented. A semiconductor based gamma ray detector requires a material with high Z, high density, high resistivity, appropriate bandgap (1.5-2 eV), low energy/electron-hole pair, and a high {mu}{tau} product. CZT is currently the best semiconductor material for room temperature gamma ray spectroscopy; however, it is extremely difficult to produce large volumes of detector grade material, making it expensive and in limited supply. DNDO/DHS began searching for other materials that might perform as well as CZT but be easier to grow and in the end lower the cost. For this purpose, we investigated the above three materials as possible replacements for CZT as gamma ray detectors. The bulk resistivity, I-V curves, X-ray response, and gamma ray response measurements for doped and undoped crystals are presented and discussed. TAS shows good X-ray and gamma ray response, but has poor resistivity, which results in large dark current and poor spectral response. TGS has good resistivity, but shows poor X-ray and gamma ray response. THI has excellent resistivity, shows some X-ray and gamma ray response, and has great potential as a gamma ray detector.

  20. Thallium(I copper(I thorium(IV triselenide, TlCuThSe3

    Directory of Open Access Journals (Sweden)

    James A. Ibers

    2012-07-01

    Full Text Available Thallium(I copper(I thorium(IV triselenide, TlCuThSe3, crystallizes with four formula units in the space group Cmcm in the KCuZrS3 structure type. There is one crystallographically independent Th, Tl, and Cu atom at a site of symmetry 2/m.., m2m, and m2m, respectively. There are two crystallographically independent Se atoms at sites of symmetry m.. and m2m. The structure consists of sheets of edge-sharing ThSe6 octahedra and CuSe4 tetrahedra stacked parallel to the (010 face, separated by layers filled with chains of Tl running parallel to [100]. Each Tl is coordinated by a trigonal prism of Se atoms.

  1. Pulse shaping for fast coincidence with NaI(Tl) detectors

    International Nuclear Information System (INIS)

    Bose, S.; Sinha, B.K.; Bhattacharya, R.

    1983-01-01

    The effect of multiple limiting of the anode pulses of the photomultiplier tubes on the resolving time of an NaI(Tl)-NaI(Tl) fast coincidence set up is investigated with the help of a simple transistored limiter circuit. The performance of the set up for different energy ranges selected in the side channels is also investigated. (orig.)

  2. Computerized study with /sup 201/Tl of the cold thyroid node

    Energy Technology Data Exchange (ETDEWEB)

    Palermo, F.; Saitta, B.; Coghetto, F.; Tiberio, M.; Caldato, L.

    1982-02-01

    Because of its physical and potassium-metabolic characteristics /sup 201/Tl is more suitable than /sup 131/Cs for radioisotopic studies of the cold thyroid nodule, with the further diagnostic possibility of quantitatively assessing intranodular behaviour for a specific differentiation among different kinds of neoformations. Using a gamma-camera on line with a computer data processing device, sequential scintiscans were recorded for the first 20-30 min after i.v. administration of 15-20 ..mu..Ci/kg of radiothallium; delayed sequences were taken at 40-60 min if intranodular uptake appeared. A quantitative appraisal was made of the differential /sup 201/Tl uptake-ratio between nodule and healthy thyroid tissue (density-index) and the multiparameter analysis of thyroid time/activity curves generated on the relative regions of interest (ROIs). This computerized study, in 120 out of 293 patients submitted to this radiothallium test, has shown a) diagnostic agreement between clinical-histological and radioisotopic findings in 76 out of 79 colloid-cystic or degenerative neoformations, in all 16 malignant and in 23 out of 25 hyperplastic benign nodules; b) significant statistical difference of the density-index in solid versus cystic but not between benign and malignant nodules; c) different /sup 201/Tl kinetics behaviour in different kinds of solid thyroid lesions with a satisfactory statistical difference of the radiothallium nodular dissappearance-index.

  3. Ab-Initio analysis of TlBr: limiting the ionic current without degrading the electronic one

    Science.gov (United States)

    Rocha Leao, Cedric; Lordi, Vincenzo

    2011-03-01

    Although TlBr in principle presents all the theoretical requirements for making high resolution room temperature radiation detectors, practical applications of TlBr have proven to be nonviable due to the polarization that is observed in the crystal after relatively short periods of operation. This polarization, that is believed to be caused by accumulation of oppositely charged ionic species at the ends of the crystal, results in an electric field that opposes that of the applied bias, counter-acting its effect. In this work, we use state of the art quantum modeling to benchmark the theoretical limits for the performance of TlBr as a radiation detector, showing that the best experimental reports demonstrate near-ideal electronic characteristics. We then propose a model to inhibit the detrimental ionic current in the material without impacting the excellent properties of the electronic current. Prepared by LLNL under Contract DE-AC52-07NA27344.

  4. Estimating distribution parameters of annual maximum streamflows in Johor, Malaysia using TL-moments approach

    Science.gov (United States)

    Mat Jan, Nur Amalina; Shabri, Ani

    2017-01-01

    TL-moments approach has been used in an analysis to identify the best-fitting distributions to represent the annual series of maximum streamflow data over seven stations in Johor, Malaysia. The TL-moments with different trimming values are used to estimate the parameter of the selected distributions namely: Three-parameter lognormal (LN3) and Pearson Type III (P3) distribution. The main objective of this study is to derive the TL-moments ( t 1,0), t 1 = 1,2,3,4 methods for LN3 and P3 distributions. The performance of TL-moments ( t 1,0), t 1 = 1,2,3,4 was compared with L-moments through Monte Carlo simulation and streamflow data over a station in Johor, Malaysia. The absolute error is used to test the influence of TL-moments methods on estimated probability distribution functions. From the cases in this study, the results show that TL-moments with four trimmed smallest values from the conceptual sample (TL-moments [4, 0]) of LN3 distribution was the most appropriate in most of the stations of the annual maximum streamflow series in Johor, Malaysia.

  5. Surface defect free growth of a spin dimer TlCuCl{sub 3} compound crystals and investigations on its optical and magnetic properties

    Energy Technology Data Exchange (ETDEWEB)

    Ryu, Gihun, E-mail: G.Ryu@fkf.mpg.de [Max Planck Institute for Solid State Research, Heisenbergstraße 1, 70569 Stuttgart (Germany); Son, Kwanghyo [Max Planck Institute for Intelligent Systems, Heisenbergstraße 3, 70569 Stuttgart (Germany)

    2016-05-15

    A defect-free high quality single crystal of spin dimer TlCuCl{sub 3} compound is firstly synthesized at the optimal growth temperature using the vertical Bridgman method. In this study, we clearly found that the cupric chloride is easily decomposed into the Cl{sup −} deficient composition at ≥470 °C. The Cl{sup −}- related gas phase at the high temperature region also always gives rise to a pinhole-like surface defect at the surface of crystal. Therefore, we clearly verified an exotic anisotropic magnetic behavior (anisotropic ratio of M{sub b}/M{sub (201)} at 2 K, 7 T=10) using the defect-free TlCuCl{sub 3} crystals in this three-dimensional spin dimer TlCuCl{sub 3} compound, relatively stronger magnetic ordering in the H//b than that of H//(201) direction at above the transition magnetic field. - Graphical abstract: A single crystal of spin dimer TlCuCl{sub 3} compound with a defect free is successfully synthesized on the basis of TG/DTA result. We newly found that this cupric chloride compound is easily decomposed into the Cl{sup −} deficient composition at ≥470 °C and Cl{sup −} related gas phases also give rise to the defects like a pinhole on the surface of TlCuCl{sub 3} crystal. Using the crystals with a surface defect free, we also clearly verified the crystal structure of spin dimer TlCuCl{sub 3} compound.

  6. Coronary collateral circulation during exercise assessed with stress Tl-201 SPECT

    International Nuclear Information System (INIS)

    Tanaka, Takeshi; Aizawa, Tadanori

    1995-01-01

    Stree Tl-201 single photon emission computed tomography (SPECT) was undertaken in 25 patients with complete occlusion of the left anterior descending artery in which the major collateral circulation was septal segment supplied by the right posterior descending artery with no significant occlusion. The ratio of blood flow in ischemic area to that in normal area was quantitatively determined on Tl-201 images, and the degree of ischemia was expressed by Tl uptake ratio. Ischemia was found in 22 of the 25 patients. Of the 22 patients, 9 showed Tl uptake ratio of less than 50%. Tl uptake ratio in the inferior segment was 76.8±10.3%. In 11 patients, it was less than 75%. Redistribution images were acquired in 19 patients. Changes in Tl uptake ratio on the 90 degrees projection of the septum were less than 20%, with a lowest value of 59.1±11.3% in 14 patients; and these were 20% or more, with a lowest value of 45.2±11.1% in 8 patients. When coronary collateral circulation is not supplied by exercise, septal perfusion may be decreased. In cases of complete occlusion of the anteiror descending artery, ischemia may not uniform over the whole ischemic area and may be noticeable around the anterior descending artery. In cases of lesions in the anteior descending artery, however, collateral circulation supplied by the right coronary artery may occur by exercise when ischemia in the anterior segment was severer than in the septal segment. (N.K.)

  7. Sand as in situ TL dosimeter in radiation hygienisation of sewage sludge

    International Nuclear Information System (INIS)

    Benny, P.G.; Bhatt, B.C.

    1999-01-01

    Recently, we have investigated the thermoluminescence (TL) properties of the sand, collected from the sewage sludge, after various extensive cleansing procedures. In the present studies, the sand separated from the sludge was used to estimate irradiation dose to sludge at Sludge Hygienisation Research Irradiator (SHRI), Vadodara, India. A dose vs TL response calibration curve was established for the 220 deg. C TL peak for the hydrogen peroxide (H 2 O 2 )-treated and HF-treated sludge sand samples collected from the unirradiated batch. This was used to estimate the dose absorbed in the corresponding batch of the irradiated sludge. Similar curve was plotted for the 370 deg. C TL peak for the HF-treated sand samples for its application as an in-situ dosimeter. Using this method, the absorbed dose rate delivered to the sludge during irradiation at SHRI was estimated to be 0.49 ± 0.02 kGy per hour. Also, the saturation levels of the TL response curves for these peaks are reported here. (author)

  8. TL and ESR based identification of gamma-irradiated frozen fish using different hydrolysis techniques

    Science.gov (United States)

    Ahn, Jae-Jun; Akram, Kashif; Shahbaz, Hafiz Muhammad; Kwon, Joong-Ho

    2014-12-01

    Frozen fish fillets (walleye Pollack and Japanese Spanish mackerel) were selected as samples for irradiation (0-10 kGy) detection trials using different hydrolysis methods. Photostimulated luminescence (PSL)-based screening analysis for gamma-irradiated frozen fillets showed low sensitivity due to limited silicate mineral contents on the samples. Same limitations were found in the thermoluminescence (TL) analysis on mineral samples isolated by density separation method. However, acid (HCl) and alkali (KOH) hydrolysis methods were effective in getting enough minerals to carry out TL analysis, which was reconfirmed through the normalization step by calculating the TL ratios (TL1/TL2). For improved electron spin resonance (ESR) analysis, alkali and enzyme (alcalase) hydrolysis methods were compared in separating minute-bone fractions. The enzymatic method provided more clear radiation-specific hydroxyapatite radicals than that of the alkaline method. Different hydrolysis methods could extend the application of TL and ESR techniques in identifying the irradiation history of frozen fish fillets.

  9. Recommendations for the measurement 131I in human thyroid using a detector of NaI(Tl)

    International Nuclear Information System (INIS)

    Puerta Yepes, N.; Rojo, A.M.; Andres, P.A.

    2010-01-01

    The Argentine Total Body Counter Laboratory of the Nuclear Regulatory Authority participated in the last regional intercomparison Exercise organized in the frame of the IAEA Project RLA 9/066 related with in vivo measurements of 131 I in the thyroid. There were identified some difficulties in determining the efficiency and calibration factor (CF) for the 131 I when a source of 133 Ba and a detector of NaI (Tl) are used in the calibration process. Independent measurements were performed for two calibration sources of known activity ( 133 Ba and 131 I) with identical geometry pattern and using a gamma spectrometry system with NaI(Ti) detector. It was found that the region of interest (ROI) which, both in the spectrum of 133 Ba as in the spectrum of 131 I, had the same efficiency. It was determined the activity of the source of 133 Ba , distributed in the intercomparison, and the calibrated source of 131 I using different values of efficiency and FC obtained. It was analyzed the conditions under which the use of 133 Ba as a source of calibration is effective for the measurement of 131 I. (authors) [es

  10. New aspects of cellular thallium uptake: Tl+-Na+-2Cl--cotransport is the central mechanism of ion uptake

    International Nuclear Information System (INIS)

    Sessler, M.J.; Maul, F.D.; Hoer, G.; Munz, D.L.; Geck, P.

    1986-01-01

    Cellular uptake mechanisms of 201 Tl + were studied in Ehrlich mouse ascites tumor cells. 201 Tl + phases the cell membrane of tumor cells using three transport systems: the ATPase, the Tl + -Na + -2Cl - -cotransport, and the Ca ++ -dependent ion channel. In the case of 201 Tl + the main route for entering the cells was the cotransport, its importance increasing with the age of the cells; in parallel, the ATPase activity was reduced. In contrast, the transport capacities of the ATPase and the cotransport were of the same magnitude in the case of 42 K + and 86 Rb + . This change in ion distribution was not brought about by varying velocity relations but by changing the number of transport systems in the cell membrane. There was no relationship between transport rates and diameters of the ions. 201 Tl + distribution is proportional to that of K + with a higher intracellular concentration of about 30%. Under physiological conditions the cotransport was reversible suggesting the ability to regulate steady state during varying extracellular ion concentrations. Cells and medium were two compartments, kinetically seen. Due to the significant difference of transport capacities between the three systems with the respective ions the term ''potassium-thallium-analogy'' may be misleading as it erroneously assumes identical uptake conditions. (orig.) [de

  11. Novel interplay between high-Tc superconductivity and antiferromagnetism in Tl-Based Six-CuO2-layered cuprates. 205Tl- and 63Cu-NMR probes

    International Nuclear Information System (INIS)

    Mukuda, Hidekazu; Shiki, Nozomu; Kimoto, Naoki; Yashima, Mitsuharu; Kitaoka, Yoshio; Tokiwa, Kazuyasu; Iyo, Akira

    2016-01-01

    We report 63 Cu- and 205 Tl-NMR studies on six-layered (n = 6) high-T c superconducting (SC) cuprate TlBa 2 Ca 5 Cu 6 O 14+δ (Tl1256) with T c ∼ 100 K, which reveal that antiferromagnetic (AFM) order takes place below T N ∼ 170 K. In this compound, four underdoped inner CuO 2 planes [n(IP) = 4] sandwiched by two outer planes (OPs) are responsible for the onset of AFM order, whereas the nearly optimally-doped OPs responsible for the onset of bulk SC. It is pointed out that an increase in the out-of-plane magnetic interaction within an intra-unit-cell causes T N ∼ 45 K for Tl1245 with n(IP) = 3 to increase to ∼170 K for Tl1256 with n(IP) = 4. It is remarkable that the marked increase in T N and the AFM moments for the IPs does not bring about any reduction in T c , since T c ∼ 100 K is maintained for both compounds with nearly optimally doped OP. We highlight the fact that the SC order for n ≥ 5 is mostly dominated by the long-range in-plane SC correlation even in the multilayered structure, which is insensitive to the magnitude of T N and the AFM moments at the IPs or the AFM interaction among the IPs. These results demonstrate a novel interplay between the SC and AFM orders when the charge imbalance between the IPs and OP is significantly large. (author)

  12. CsI(Tl) with photodiodes for identifying subsurface radionuclide contamination

    International Nuclear Information System (INIS)

    Stromswold, D.C.; Meisner, J.E.; Nicaise, W.F.

    1994-10-01

    At the US Department of Energy's Hanford Site near Richland, Washington, underground radioactive contamination exists as the result of leaks, spills, and intentional disposal of waste products from plutonium-production operations. Characterizing these contaminants in preparation for environmental remediation is a major effort now in progress. In this paper, a cylindrical (15 x 61 mm) CsI(Tl) scintillation detector with two side-mounted photodiodes has been developed to collect spectral gamma-ray data in subsurface contaminated formations at the U.S. Department of Energy's Hanford Site. It operates inside small-diameter, thick-wall steel pipes pushed into the ground to depths up to 20 m by a cone penetrometer. The detector provides a rugged, efficient, magnetic-field-insensitive means for identifying gamma-ray-emitting contaminants (mainly 137 Cs and 60 Co). Mounting two 3 x 30-mm photodiodes end-to-end on a flat area along the detector's side provides efficient light collection over the length of the detector

  13. RDM lifetime measurements in 187Tl

    International Nuclear Information System (INIS)

    Chamoli, S.K.; Joshi, P.; Kumar, A.; Govil, I.M.; Mukherjee, G.; Singh, R.P.; Muralithar, S.; Bhowmik, R.K.

    2003-01-01

    The present work is an attempt to study the shape changes in 187 Tl through a measurement of electromagnetic transition probabilities of the high spin states. The Doppler shifted recoil distance technique was used to measure the lifetimes

  14. Concentration dependence of the light yield and energy resolution of NaI:Tl and CsI:Tl crystals excited by gamma, soft X-rays and alpha particles

    CERN Document Server

    Trefilova, L N; Kovaleva, L V; Zaslavsky, B G; Zosim, D I; Bondarenko, S K

    2002-01-01

    Based on the analysis of light yield dependence on activator concentration for NaI:Tl and CsI:Tl excited by gamma-rays, soft X-rays and alpha-particles, an explanation of the effect of energy resolution enhancement with the rise of Tl content has been proposed. Based on the concept regarding the electron track structure, we proposed an alternative explanation of the intrinsic resolution value. The concept does not take into account the non-proportional response to electrons of different energies and is based on the statistic fluctuation of scintillation photon number formed outside and inside the regions of higher ionization density.

  15. Evaluation of myocardial damage and cardiac residual capacity by Tl-201 myocardial scintigraphy in valvular heart diseases

    International Nuclear Information System (INIS)

    Indo, Shunju

    1992-01-01

    This study was performed to clarify whether the extent-score (Ex-Score) calculated by Tl-201 myocardial scintigraphy is a reliable indicator of the severity of myocardial damage and cardiac residual capacity in valvular heart diseases. The subjects consisted of 38 patients (10 with aortic regurgitation (AR), 4 with aortic stenosis (AS), 13 with mitral regurgitation (MR) and 11 with mitral stenosis (MS)). Ex-Scores were significantly correlated with the severity of myocardial damage found in biopsied specimens obtained intraoperatively (correlation efficiency to Ex-Score with cell diameter in AR, % fibrosis in AR, cell diameter in AS, electron microscopic score in MR and % fibrosis in MS was 0.873, 0.734, 0.970, 0.913 and 0.659, respectively). Ex-Scores were also correlated with cardiac residual capacity determined by radioisotope angiography (correlation efficiency to Ex-Score with %Δ ejection fraction in AR, %Δ end-systolic volume in MR, %Δ end-diastolic volume in MS was -0.764, 0.790 and -0.763, respectively). These results suggest that the severity of myocardial damage and cardiac residual capacity can be estimated by Tl-201 myocardial scintigraphy (Ex-Score) in valvular heart diseases. (author)

  16. On the Constitution of SoTL: Its Domains and Contexts

    Science.gov (United States)

    Booth, S.; Woollacott, L. C.

    2018-01-01

    In this paper, we present an analysis of the Scholarship of Teaching and Learning in Higher Education (SoTL) which contributes to SoTL both as a field of research practice and as a background to professional development in higher education. We analyse and describe the constitution of the field, and in so doing address its nature in the face of the…

  17. Value of dipyridamole stress 201Tl myocardial SPECT in detecting dysfunction of coronary microcirculation

    International Nuclear Information System (INIS)

    Lou Ying; Jiang Jinqi; Xie Wenhui; Yuan Fang; Wang Tong; Yang Yiqing

    2012-01-01

    Objective: To evaluate the value of dipyridamole stress 201 Tl myocardial SPECT in detecting dysfunction of coronary microcirculation. Methods: Forty-eight patients diagnosed with cardiac syndrome X underwent dipyridamole stress 201 Tl myocardial SPECT. Dipyridamole (0.56 mg/kg) was intravenously injected over 4 min followed by 201 Tl (111 MBq) injection at 2 min after dipyridamole administration. Image was acquired at 10 min and 240 min post-injection and co-analyzed by over two experienced doctors in nuclear medicine after three-dimensional reconstruction. The patients with 'reverse redistribution' underwent repeated dipyridamole stress 201 Tl SPECT after medical therapy for 2 weeks. The clinical symptoms and results of the treadmill exercise test pre-and post-therapy were compared. Results: Forty two patients (42/48, 87.50%) showed segmental defects: 'reverse redistribution' on delayed (240 min) 201 Tl images. After medical treatment, 36 cases of the 42 'reverse redistribution' patients had improvement in both clinical symptoms and treadmill exercise test. Post-treatment 201 Tl imaging showed improvement in 45/49 (91.84%) defect segments. Six of the 42 patients had no improvement in clinical symptoms and/or treadmill exercise test. Post-treatment 201 Tl imaging showed no improvement in all the 7 defect segments on the first scan. Conclusion: Dipyridamole stress 201 Tl myocardial SPECT may be valuable in evaluation of impaired coronary microcirculation associated with cardiac syndrome X. (authors)

  18. Measuring naturally occurring uranium in soil and minerals by analysing the 352 keV gamma-ray peak of 214Pb using a NaI(Tl)-detector

    International Nuclear Information System (INIS)

    Bezuidenhout, J.

    2013-01-01

    This article investigates the prospect of utilising the 351.9 keV gamma-ray of 214 Pb when determining the concentration of uranium. Soil samples were collected from various locations around South Africa and laboratory gamma ray spectra for each were obtained by means of a NaI(Tl)-detector (7.62×7.62 cm 2 ). The potassium, uranium and thorium concentrations where extracted by analysing gamma ray peaks that are associated with these radionuclides. Two separate uranium concentrations were extracted; one by means of the 214 Pb decay and the other one by means of the 214 Bi decay. These uranium concentrations were compared in terms of accuracies and detection limits. - Highlights: • Investigated a method to improve uranium concentrations measurements. • Expansion on an existing method that analyses naturally occurring radionuclides. • Utilise pill containers opposed to Marrinelli beakers. • Possible application to in situ measurements. • The method utilise NaI(Tl)-detectors with relative high efficiency

  19. High-pressure single-crystal X-ray diffraction of Tl2SeO4

    International Nuclear Information System (INIS)

    Grzechnik, Andrzej; Breczewski, Tomasz; Friese, Karen

    2008-01-01

    The effect of pressure on the crystal structure of thallium selenate (Tl 2 SeO 4 ) (Pmcn, Z=4), containing the Tl + cations with electron lone pairs, has been studied with single-crystal X-ray diffraction in a diamond anvil cell up to 3.64 GPa at room temperature. No phase transition has been observed. The compressibility data are fitted by a Murnaghan equation of state with the zero-pressure bulk modulus B 0 =29(1) GPa and the unit-cell volume at ambient pressure V 0 =529.6(8) A 3 (B'=4.00). Tl 2 SeO 4 is the least compressible in the c direction, while the pressure-induced changes of the a and b lattice parameters are quite similar. These observations can be explained by different pressure effects on the nine- and 11-fold coordination polyhedra around the two non-equivalent Tl atoms. The SeO 4 2- tetrahedra are not rigid units and become more distorted. Their contribution to the compressibility is small. The effect of pressure on the isotypical oxide materials A 2 TO 4 with the β-K 2 SO 4 structure is discussed. It appears that the presence of electron lone pairs on the Tl + cation does not seem to influence the compressibility of Tl 2 SeO 4 . - Graphical abstract: Pressure dependence of normalized lattice parameters and unit-cell volumes in Tl 2 SeO 4 (Pmcn, Z=4). The solid line is the Murnaghan equation of state

  20. Photoluminescence and absorption spectra of various common TL phosphors - interpretation of TL mechanisms

    International Nuclear Information System (INIS)

    Nagpal, J.S.

    1980-01-01

    Photoluminescence and absorption spectra of TL phosphors TLD-100, CaF 2 :Dy, CaSO 4 :Dy(0.05%wt), CaSO 4 :Tm(0.05%wt) and Mg 2 SiO 4 :Tb have been measured. The absorption spectra are typical of RE 2+ in rare earth doped irradiated phosphors. On heating RE 2+ yields RE 3+ and emission from the excited states of RE 3+ is observed. (author)

  1. Mechanisms of TL for production of the 230 {sup o}C peak in natural sodalite

    Energy Technology Data Exchange (ETDEWEB)

    Cano, Nilo F., E-mail: nilocano@dfn.if.usp.b [Institute of Physics, University of Sao Paulo, Rua do Matao, Travessa R, 187, CEP 05508-090, Sao Paulo (Brazil); Professional School of Physics, University of San Agustin of Arequipa, Av. Independencia S/N, Arequipa (Peru); Blak, Ana R. [Institute of Physics, University of Sao Paulo, Rua do Matao, Travessa R, 187, CEP 05508-090, Sao Paulo (Brazil); Ayala-Arenas, Jorge S. [Professional School of Physics, University of San Agustin of Arequipa, Av. Independencia S/N, Arequipa (Peru); Watanabe, Shigueo [Institute of Physics, University of Sao Paulo, Rua do Matao, Travessa R, 187, CEP 05508-090, Sao Paulo (Brazil)

    2011-02-15

    The thermoluminescence (TL) peak in natural sodalite near 230 {sup o}C, which appears only after submitted to thermal treatments and to gamma irradiation, has been studied in parallel with electron paramagnetic resonance (EPR) spectrum appearing under the same procedure. This study revealed a full correlation between the 230 {sup o}C TL peak and the eleven hyperfine lines from EPR spectrum. In both case, the centers disappear at the same temperature and are restored after gamma irradiation. A complete model for the 230 {sup o}C TL peak is presented and discussed. In addition to the correlation and TL model, specific characteristics of the TL peaks are described.

  2. ABA content in shoots and roots of pea mutants af and tl as related to their growth and morphogenesis

    Czech Academy of Sciences Publication Activity Database

    Kof, E.M.; Vinogradova, I.A.; Oorzhak, A.S.; Karyagin, V.V.; Kalibernaya, Z.V.; Macháčková, Ivana; Kondykov, I.V.; Chuvasheva, E.S.

    2006-01-01

    Roč. 53, č. 3 (2006), s. 359-365 ISSN 1021-4437 Institutional research plan: CEZ:AV0Z50380511 Keywords : Pisum sativum * af and tl leaf mutants * morphogenesis Subject RIV: EF - Botanics Impact factor: 0.321, year: 2006

  3. Effects of smoking on lung uptake of 201Tl during exercise myocardial perfusion imaging

    International Nuclear Information System (INIS)

    Ouyang Wei; He Guorong; Liu Jinhua

    2004-01-01

    Objective: To investigate the influence of smoking on lung uptake of 201 Tl during myocardial perfusion imaging. Methods: Ninety-two healthy subjects, with normal 201 Tl myocardial perfusion imaging findings but no evidence of left ventricular hypertrophy and pulmonary disease, were divided into three groups, smoker, nonsmoker and quitted smoker groups. Exercise/delay 201 Tl myocardial perfusion imaging was performed on all subjects included. Lung/heart ratio was defined on the anterior planar image obtained during exercise tomography. Results: Both the lung/heart ratios during exercise in smoker (0.40 ± 0.07, F=10.635, P 201 Tl lung/heart ratios in smokers are higher than in nonsmokers and this must be kept in mind when 201 Tl lung/heart ratios are used clinically, even in quitted smokers

  4. The model of recombination process in TlBr

    International Nuclear Information System (INIS)

    Grigorjeva, L.; Millers, D.

    2002-01-01

    The time-resolved luminescence was used as a tool in the study of recombination process in several undoped TlBr crystals. The spectra and decay kinetics observed under electron beam excitation were investigated. Observation of several luminescence bands with different decay rates shows that more than one recombination center is involved and the recombination process is quite complicated. The band at ∼2.5 eV is dominant under 10 ns excitation pulse (electron beam or nitrogen laser pulses). The results of short-lived absorption and luminescence are used for analysis of possible mechanisms of recombination processes in TlBr

  5. Effect of particle size in the TL response of natural quartz sensitized by high dose of gamma radiation and heat-treatments

    Directory of Open Access Journals (Sweden)

    Álvaro Barbosa de Carvalho Jr

    2010-06-01

    Full Text Available This work investigates the effect of particle size in the thermoluminescence (TL response of a quartz crystal that was initially crushed and classified into ten size fractions between 38 μm and 5 mm. Aliquots of each size fraction were sensitized with a dose of 25 kGy of γ rays and heat-treatments at 400 °C. TL glow curves of sensitized and non-sensitized samples were recorded as a function of different test-doses of γ rays. For the non-sensitized samples, the TL peak near 325 °C increases with the decrease in particle size. In the case of sensitized samples, a strong TL peak near 300 °C increases with the increase in particle size up to mean grain size equal to 304 μm. Above 304 μm, an abrupt reduction in the TL intensity is noticed for the sensitized peak. These effects are discussed in relation to the specific surface area of quartz particles and the intensity of the electron paramagnetic resonance signal of the E'1 center induced by the sensitization process.

  6. Clinical evaluation of the Tl-201 ECG-gated myocardial SPECT

    International Nuclear Information System (INIS)

    Mochizuki, Teruhito

    1989-01-01

    In order to evaluate the clinical usefulness of the Tl-201 ECG-gated myocardial single photon emission computed tomography (SPECT), we compared the wall motion and the grade of the Tl-201 uptake of the ECG-gated myocardial SPECT with the wall motion of the ECG-gated blood pool SPECT. Materials were 87 patients of 50 old myocardial infarctions (OMIs), 19 hypertrophic cardiomyopathies (HCMs), 2 dilated cardiomyopathies (DCMs) and 16 others. After intravenous injection of 111-185 MBq (3-5 mCi) of Tl-201 at rest, the projection data were acquired using a rotating gamma-camera through 180deg, from RAO 45deg in 24 directions, each of which consisted of 80-100 beats. For the reconstruction of ED, ES and non-gated images, R-R interval was divided into about 20 (18-22) fractions. In 348 regions of interest (anterior, septal, lateral and inferior wall) in 87 cases, wall motion and the Tl-201 uptake were evaluated to three grades (normal, hypokinesis and akinesis; normal, low and defect, respectively), which were compared with the wall motion of the ECG-gated blood pool SPECT. The wall motion and the grade of the Tl-201 uptake of the ECG-gated myocardial SPECT correlated well with the wall motion of the ECG-gated blood pool SPECT (96.6% and 87.9%, respectively). In conclusion, the ECG-gated myocardial SPECT can provide clear perfusion images and is a very useful diagnostic strategy to evaluate the regional wall motion and perfusion simultaneously. (author)

  7. Minimising the Spurious TL of Recently Fired Ceramics Using the Foil Technique

    International Nuclear Information System (INIS)

    Michael, C.T.; Zacharias, N.; Polikreti, K.; Pagonis, V.

    1999-01-01

    The new foil technique for measuring the natural dose in TL dating is briefly presented. In this technique very thin samples are made with the necessary plasticity to achieve the best heating contact between sample and heater plate. Measurements can then be made in vacuum and it is possible to use higher heating rates. The effect of the increase of the TL signal with the increase of the heating rate is presented. The foil technique reduces chemiluminescence and increases the TL signal. This allows the application of TL dating to be extended to lower limits (lower ages). These limits are determined by estimating quantitatively the effects of the sample preparation procedure on the induction of spurious TL (triboluminescence). Samples from a two year old ceramic vase were prepared with two different powder preparation procedures: (a) by using a hand drill with a common steel edge and (b) by crushing a piece using a vice. Measurements at a heating rate of 50 deg. C.s -1 were made. The two estimates of P (total dose) provide an estimate of age for each procedure. The age estimation for the vice prepared sample is about 30 years and for the drilled sample is higher than 120 years. It is suggested that the use of a drill for powder preparation be avoided, especially in TL dating and authenticity tests of recently fired ceramics (less than 500 years). (author)

  8. Portable in situ NaI(Tl) γ spectroscopy system

    International Nuclear Information System (INIS)

    Wang Bairong; Dong Binjiang; Zeng Liping; Shen Tingyun

    2000-01-01

    The author describes a portable in situ NaI(Tl) γ spectroscopy system, which consists of a NaI (Tl) scintillation detector, an integrative spectroscopy card, a notebook computer and spectroscopy software. The spectrometer addresses applications in environmental or nuclear accident in situ γ spectroscopy measurements, and gives valid quantitative results of radionuclide concentrations per unit volume (Bq/kg) or unit area (Bq/cm 2 ) in the soil and absorbed dose rate in air at 1 m above ground (Gy/h)

  9. Examination of TL and optical absorption in calcite's mineral

    International Nuclear Information System (INIS)

    Sabikoglu, I.; Can, N.

    2009-01-01

    Calcite which is a form of crystalline of the calcium carbonate composes parent material of chalk stone (limestone) and marble. Calcite which presents in various colors also in our country consists of yellow, blue, transparent and green colors. In this study, green calcite mineral which is taken from the region of Ayvalik, was examined of its thermoluminescence (TL) and optical absorption features in different doses. It has been obtained a large TL peak in 179 degree C and absorption peak in 550 mm.

  10. Absorbed radiation to the nuclear medicine nurses from patients administered 201Tl and 99mTc- MIBI

    International Nuclear Information System (INIS)

    Sattari, Ali; Dadashzadeh, Simin; Nasiroghli, G.; Firoozabadi, Hasan

    2008-01-01

    People who have administrated radiopharmaceuticals could be a source of radiation to their relatives, medical nurses, and people who have contact them. In this study, the dose rates at various distances of 5, 10,50 and 100 cm from 70 patients, who were administered diagnostic amounts of 201 Tl -Chloride and 99m Tc -MIBI, was measured using an ionization chamber. For determination of external radiation dose to the nurses the radiations in three deferent interval times have measured. The maximum values of external dose rates of 201 Tl and 99m Tc-MIBI were 11.2μSv/h ±2.3 and 43.1μSv/h ±11.9 respectively at 5 cm from the patients. Significant exposure from patients after injection of 99m Tc -MIBI was limited on the day of administration. Departure doses rate of 201 Tl fell gradually so by 3 days after administration was significant. Maximum and average absorbed dose of nuclear medicine staff for one 201 Tl scan was 4.6 and 2.7μSv/h, and for 99m Tc-MIBI was 18.1 and 9.8μSv/h in a working day. (author)

  11. Magnetic excitations and exchange interactions in the spin-gap system TlCuCl sub 3

    CERN Document Server

    Oosawa, A; Kato, T; Kakurai, K; Müller, M; Mikeska, H J

    2002-01-01

    The magnetic excitations from the gapped ground state in TlCuCl sub 3 have been investigated by means of inelastic neutron scattering experiments. The excitation data were collected along four different directions in the a sup * -c sup * plane. A well-defined single magnetic excitation mode was observed. The lowest excitation occurs at Q=(h,0,l) with integer h and odd l, as observed in KCuCl sub 3. The dispersion relations were analyzed by the cluster-series expansion up to the sixth order, so that the individual exchange interactions were evaluated. It was demonstrated that TlCuCl sub 3 is a strongly coupled spin-dimer system. (orig.)

  12. Influence of deep traps in the Tl response of ZrO{sub 2} + PTFE; Influencia de las trampas profundas en la respuesta Tl de ZrO{sub 2} + PTFE

    Energy Technology Data Exchange (ETDEWEB)

    Rivera M, T.; Azorin N, J.; Falcony G, C.; Martinez S, E.; Garcia H, M. [Universidad Autonoma Metropolitana-Iztapalapa, 09340 Mexico D.F. (Mexico)

    2000-07-01

    In this work are presented the results from investigating the processes related with the defects produced by ionizing radiation in ZrO{sub 2}. It is established an hypothesis which pretends to explain the phenomena that implicates the manifestation of Tl peaks in the brightness curve due to electron removal from the surface traps to the deep traps, through the thermo-transference process, where the excitonic process correspond to the F centers. During the experimental process it was observed this effect through the peaks running in Tl curve. These peaks are presented at 220 and 360 Centigrade for the material without any previous thermal treatment; while that in the samples thermally treated at 100 Centigrade during 1 minute it is observed a slipping in the first peak from 220 to 280 Centigrade, while the second stays in 360 Centigrade. (Author)

  13. Brain SPECT with Tl-201 DDC

    International Nuclear Information System (INIS)

    Bruine, J.F. de.

    1988-01-01

    The development, animal and human experiments and the first clinical results of a new blood flow tracer thallium-201 diethyldithiocarbamate (Tl-201 DDC) are discussed for functional brain imaging with single-photon emission computed tomography (SPECT). 325 refs.; 43 figs.; 22 tabs

  14. Point Defect Properties of Cd(Zn)Te and TlBr for Room-Temperature Gamma Radiation Detectors

    Science.gov (United States)

    Lordi, Vincenzo

    2013-03-01

    The effects of various crystal defects in CdTe, Cd1-xZnxTe (CZT), and TlBr are critical for their performance as room-temperature gamma radiation detectors. We use predictive first principles theoretical methods to provide fundamental, atomic scale understanding of the defect properties of these materials to enable design of optimal growth and processing conditions, such as doping, annealing, and stoichiometry. Several recent cases will be reviewed, including (i) accurate calculations of the thermodynamic and electronic properties of native point defects and point defect complexes in CdTe and CZT; (ii) the effects of Zn alloying on the native point defect properties of CZT; (iii) point defect diffusion and binding related to Te clustering in Cd(Zn)Te; (iv) the profound effect of native point defects--principally vacancies--on the intrinsic material properties of TlBr, particularly electronic and ionic conductivity; (v) tailored doping of TlBr to independently control the electronic and ionic conductivity; and (vi) the effects of metal impurities on the electronic properties and device performance of TlBr detectors. Prepared by LLNL under Contract DE-AC52-07NA27344 with support from the National Nuclear Security Administration Office of Nonproliferation and Verification Research and Development NA-22.

  15. EPR and TL correlation in some powdered Greek white marbles

    International Nuclear Information System (INIS)

    Baieetto, Vanessa; Villeneuve, Gerard; Guibert, Pierre; Schvoerer, Max

    2000-01-01

    Thermoluminescence of white powdered marble samples, chosen to display different EPR spectra, were studied. Two peaks at 280 deg. C and 360 deg. C can be observed among the TL glow curves while the EPR spectra exhibit two signals: the A signal with g perp =2.0038 and g par =2.0024 due to the SO - 3 centre and the B one with g 1 =2.0005; g 2 =2.0001; g 3 =1.9998 due to mechanical powder reduction (drilling). Owing to heating and simultaneous experiments, a correlation have been established: the 280 deg. C TL peak is associated to the A signal and thus to the SO - 3 centre and the 360 deg. C TL peak is caused by mechanical treatment corresponding to the B EPR signal

  16. EPR and TL correlation in some powdered Greek white marbles.

    Science.gov (United States)

    Baïetto, V; Villeneuve, G; Guibert, P; Schvoerer, M

    2000-02-01

    Thermoluminescence of white powdered marble samples, chosen to display different EPR spectra, were studied. Two peaks at 280 degrees C and 360 degrees C can be observed among the TL glow curves while the EPR spectra exhibit two signals: the A signal with g perpendicular = 2.0038 and g parallel = 2.0024 due to the SO3- centre and the B one with g1 = 2.0005; g2 = 2.0001; g3 = 1.9998 due to mechanical powder reduction (drilling). Owing to heating and simultaneous experiments, a correlation have been established: the 280 degrees C TL peak is associated to the A signal and thus to the SO3- centre and the 360 degrees C TL peak is caused by mechanical treatment corresponding to the B EPR signal.

  17. Microcomputer control of automated TL reader

    International Nuclear Information System (INIS)

    Bjarland, B.

    1980-01-01

    An automatic TL reader has been developed for use within a TLD based personal monitoring service. A 6800 based microcomputer is used for system control, operator communication, calibration and checking of reader operation, and for output of data. The dosimeter identity code is printed in human readable characters on the dosimeter card, and is read by using an optical character recognition unit. The code may include individual sensitivity correction coefficients for the TL chips on the card. The chips are heated with hot nitrogen gas and the thermoluminescence is recorded by a photomultiplier tube circuit, the gain and offset of which are continuously monitored and, when necessary, adjusted, to maintain calibration. The reader may operate in any of seven modes, i.e. reading modes for three types of dosimeters, semiautomatic modes for production of the three types of dosimeters, and a monitor mode. (Auth.)

  18. Pressure-induced transition in Tl2MoO4

    International Nuclear Information System (INIS)

    Machon, Denis; Friese, Karen; Breczewski, Tomasz; Grzechnik, Andrzej

    2010-01-01

    Tl 2 MoO 4 has been studied under high-pressure by X-ray diffraction, Raman spectroscopy, and optical absorption measurements. A first-order phase transition is observed at 3.5±0.5 GPa. The nature (ordered vs. disordered) of the high-pressure phase strongly depends on the local hydrostatic conditions. Optical absorption measurements tend to show that this transition is concomitant with an electronic structure transformation. Prior to the transition, single crystal X-ray diffraction shows that pressure induces interactions between MoO 4 fragments and the Mo coordination number tends to increase. In addition, the stereoactivity of the lone-pair electrons on the three symmetrically independent Tl-sites is not uniform; while for two sites the stereoactivity decreases with increasing pressures for the third site the stereoactivity increases. - Graphical Abstract: (up) Structural evolutions of Tl 2 MoO 4 in the low-pressure phase. (Down) Optical properties of the high-pressure phase as a function of pressure. Display Omitted

  19. Phase equilibria in the Tl2MoO4–R2(MoO43–Zr(MoO42 (R = Al, Cr systems: synthesis, structure and properties of new triple molybdates Tl5RZr(MoO46 and TlRZr0.5(MoO43

    Directory of Open Access Journals (Sweden)

    V. G. Grossman

    2017-12-01

    Full Text Available The Tl2MoO4–R2(MoO43–Zr(MoO42 (R = Al, Cr systems were studied in the subsolidus region using X-ray powder diffraction and differential scanning calorimetric (DSC analysis. Quasi-binary joins were revealed, and triangulation was carried out. New ternary molybdates: Tl5RZr(MoO46 (5:1:2 and TlRZr0.5(MoO43 (1:1:1 (R = Al, Cr were prepared. The unit cell parameters for the new compounds were calculated.

  20. Efficiency correction for disk sources using coaxial High-Purity Ge detectors

    International Nuclear Information System (INIS)

    Chatani, Hiroshi.

    1993-03-01

    Efficiency correction factors for disk sources were determined by making use of closed-ended coaxial High-Purity Ge (HPGe) detectors, their relative efficiencies for a 3' 'x3' ' NaI(Tl) with the 1.3 MeV γ-rays were 30 % and 10 %, respectively. Parameters for the correction by mapping method were obtained systematically, using several monoenergetic (i.e. no coincidence summing loses) γ-ray sources produced by irradiation in the Kyoto University Reactor (KUR) core. These were found out that (1) the systematics of the Gaussian fitting parameters, which were calculated using the relative efficiency distributions of HPGe, to the γ-ray energies are recognized, (2) the efficiency distributions deviate from the Gaussian distributions outside of the radii of HPGe. (3) mapping method is a practical use in satisfactory accuracy, as the results in comparison with the disk source measurements. (author)

  1. Solvent extraction of Tl(I) with 2-mercaptobenzothiazole into chloroform

    International Nuclear Information System (INIS)

    Itawi, R.K.; Turel, Z.R.

    1984-01-01

    The extraction of Tl(I) with 2-mercaptobenzothiazole into chloroform was studied. The effect of various parameters on the extraction coefficient value was evaluated. The stoichiometry of the extracted species obtained from the substoichiometric extraction was found to be 1:1. This was further supported by the slope ratio method. Decontamination factors of a number of elements in the substoichiometric extraction of Tl(I) were also obtained. (author)

  2. Thermal analysis of chalcogenide glasses of the system (As/sub/2Se/sub/3)/sub/(1-x):(Tl/sub/2Se)/sub/x

    International Nuclear Information System (INIS)

    Majid, C.A.

    1987-01-01

    In this paper differential thermal analysis (DTA) measurements of chalcogenide glasses of the system (As/sub/2Se/sub/3)/sub/(1-x): (Tl/sub/2Se)/sub/x, with x=0, 0.125, 0.25 and 0.50 are reported. The glass-forming tendencies of these materials have been calculated. The glass-forming tendency of As/sub/2Se/sub/3 has been found to be the highest among the member glasses of this family of chalcogenides. It was found that the glass-forming tendency of As/sub/2Se/sub/3 decreasing gradually at the Tl/sub/2/Se concentration increases. Tl/sub/2Se additions lower the glass transition temperature T/sub/q and the area under the endothermic peak for glass transition temperature, suggesting a tendency for relatively weaker bonding and hence less stability of Tl-rich glass compositions. These studies show that Tl/sub/2Se concentrations result in glasses with progressively higher crystallization tendencies. (author)

  3. Recent advances in Tl Br, Cd Te and CdZnTe semiconductor radiation detectors: a review

    International Nuclear Information System (INIS)

    Oliveira, Icimone B.

    2011-01-01

    The success in the development of radiation spectrometers operating at room temperature is based on many years of effort on the part of large numbers of workers around the world. These individuals have contributed to the understanding of the fundamental materials issues associated with the growth of semiconductors for this application, the development of device fabrication and processing technology, and advances in low noise electronics and pulse processing. Progress in this field continues at an accelerated pace, as in evidenced by the improvements in detector performance and by the growing number of commercial products. Thus, the last years have been seen continued effort in the development of room temperature compound semiconductors devices. High-Z compound semiconductor detectors has been explored for high energy resolution, high detection efficiency and are of low cost. Compound semiconductors detectors are well suited for addressing needs of demanding applications such as bore hole logging where high operating temperature are encountered. In this work recent developments in semiconductors detectors were reviewed. This review concentrated on thallium bromide (TlBr), cadmium zinc telluride (CdZnTe) and cadmium telluride (CdTe) crystals detectors. TlBr has higher stopping power compared to common semiconductor materials because it has the higher photoelectric and total attenuation coefficients over wide energy range from 100 keV to 1 MeV. CdTe and CdZnTe detectors have several attractive features for detecting X-ray and low energy gamma ray. Their relatively large band gaps lead to a relatively low leakage current and offer an excellent energy resolution at room temperature. A literature survey and bibliography was also included. (author)

  4. Recent advances in Tl Br, Cd Te and CdZnTe semiconductor radiation detectors: a review

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Icimone B. [Universidade Bandeirante (UNIBAN), Sao Paulo, SP (Brazil)

    2011-07-01

    The success in the development of radiation spectrometers operating at room temperature is based on many years of effort on the part of large numbers of workers around the world. These individuals have contributed to the understanding of the fundamental materials issues associated with the growth of semiconductors for this application, the development of device fabrication and processing technology, and advances in low noise electronics and pulse processing. Progress in this field continues at an accelerated pace, as in evidenced by the improvements in detector performance and by the growing number of commercial products. Thus, the last years have been seen continued effort in the development of room temperature compound semiconductors devices. High-Z compound semiconductor detectors has been explored for high energy resolution, high detection efficiency and are of low cost. Compound semiconductors detectors are well suited for addressing needs of demanding applications such as bore hole logging where high operating temperature are encountered. In this work recent developments in semiconductors detectors were reviewed. This review concentrated on thallium bromide (TlBr), cadmium zinc telluride (CdZnTe) and cadmium telluride (CdTe) crystals detectors. TlBr has higher stopping power compared to common semiconductor materials because it has the higher photoelectric and total attenuation coefficients over wide energy range from 100 keV to 1 MeV. CdTe and CdZnTe detectors have several attractive features for detecting X-ray and low energy gamma ray. Their relatively large band gaps lead to a relatively low leakage current and offer an excellent energy resolution at room temperature. A literature survey and bibliography was also included. (author)

  5. Theoretical analysis and experimental evaluation of a CsI(Tl) based electronic portal imaging system

    International Nuclear Information System (INIS)

    Sawant, Amit; Zeman, Herbert; Samant, Sanjiv; Lovhoiden, Gunnar; Weinberg, Brent; DiBianca, Frank

    2002-01-01

    This article discusses the design and analysis of a portal imaging system based on a thick transparent scintillator. A theoretical analysis using Monte Carlo simulation was performed to calculate the x-ray quantum detection efficiency (QDE), signal to noise ratio (SNR) and the zero frequency detective quantum efficiency [DQE(0)] of the system. A prototype electronic portal imaging device (EPID) was built, using a 12.7 mm thick, 20.32 cm diameter, CsI(Tl) scintillator, coupled to a liquid nitrogen cooled CCD TV camera. The system geometry of the prototype EPID was optimized to achieve high spatial resolution. The experimental evaluation of the prototype EPID involved the determination of contrast resolution, depth of focus, light scatter and mirror glare. Images of humanoid and contrast detail phantoms were acquired using the prototype EPID and were compared with those obtained using conventional and high contrast portal film and a commercial EPID. A theoretical analysis was also carried out for a proposed full field of view system using a large area, thinned CCD camera and a 12.7 mm thick CsI(Tl) crystal. Results indicate that this proposed design could achieve DQE(0) levels up to 11%, due to its order of magnitude higher QDE compared to phosphor screen-metal plate based EPID designs, as well as significantly higher light collection compared to conventional TV camera based systems

  6. Measuring thermo-luminescence efficiency of TLD-2000 detectors to different energy photons

    Energy Technology Data Exchange (ETDEWEB)

    Xie, Wei Min; Chen, Bao Wei; Han, Yi; Yang, Zhong Jian [China Institute for Radiation Protection, Taiyuan (China)

    2016-06-15

    As an important detecting device, TLD is a widely used in the radiation monitoring. It is essential for us to study the property of detecting element. The aim of this study is to calculate the thermo-luminescence efficiency of TL elements. A batch of thermo-luminescence elements were irradiated by the filtered X-ray beams of average energies in the range 40-200 kVp, 662 keV {sup 137}Cs gamma rays and then the amounts of lights were measured by the TL reader. The deposition energies in elements were calculated by theory formula and Monte Carlo simulation. The unit absorbed dose in elements by photons with different energies corresponding to the amounts of lights was calculated, which is called the thermo luminescent efficiency (η(E)). Because of the amounts of lights can be calculated by the absorbed dose in elements multiply η(E), the η(E) can be calculated by the experimental data (the amounts of lights) divided by absorbed dose. The deviation of simulation results compared with theoretical calculation results were less than 5%, so the absorbed dose in elements was calculated by simulation results in here. The change range of η(E) value, relative to 662 keV {sup 137}Cs gamma rays, is about 30% in the energy range of 33 keV to 662 keV, is in accordance by the comparison with relevant foreign literatures. The η(E) values can be used for updating the amounts of lights that are got by the direct ratio assumed relations with deposition energy in TL elements, which can largely reduce the error of calculation results of the amounts of lights. These data can be used for the design of individual dosimeter which used TLD-2000 thermo-luminescence elements, also have a certain reference value for manufacturer to improve the energy-response performance of TL elements by formulation adjustment.

  7. Experience with TL-102M for the treatment of radiation stomatitis

    International Nuclear Information System (INIS)

    Nishio, Juntaro; Matsuya, Tokuzo; Inoue, Kazuo; Miyazaki, Tadashi; Maeda, Noriaki.

    1984-01-01

    TL-102M was administered to 14 patients who had radiation stomatitis following radiation therapy for malignant tumors in the oral cavity. Regarding the degree of overall improvement, one of the 14 patients was evaluated as ''extremely improved'', eight as ''improved'', four as ''slightly improved'', and one as ''unchanged''. None of the patients had side effects. Adherent, powdered TL-102M was easy to take for patients. Most of the patients desired to continue to take this drug because of having neither painfulness nor adhesive feeling. The usage of TL-102M could be helpful in promoting the treatment for cancer, thus suggesting that it is useful in treating radiation stomatitis. (Namekawa, K.)

  8. Anisotropic superconducting state parameters of Tl-2212 superconductors

    International Nuclear Information System (INIS)

    Khaskalam, Amit K.; Singh, R.K.; Varshney, Dinesh

    2001-01-01

    We have estimated the superconducting state parameters and their anisotropy in thallium based superconductors (Tl-2212), in the frame work of Fermi liquid approach. Determination of the effective mass of the charge carriers from the Fermi velocity and estimated anisotropic superconducting state parameters, particularly, the magnetic penetration depth along and perpendicular to the conducting plane. The coherence length along and perpendicular to the ab plane is evaluated and appears to be higher. The temperature dependence of penetration depth, their anisotropy and Ginsburg Landau parameter for optimised doped Tl based cuprates shows the power law. The technique permits a consistency with the reported data. (author)

  9. Observation of curious spiral growth features in Tl doped Hg bearing ...

    Indian Academy of Sciences (India)

    Synthesis of H(Tl)Ba2Ca2Cu3O8+ superconducting tapes have been accomplished by annealing the precursor tape, Ba2Ca2Cu3O (fabricated by doctor blade tape casting technique) in an environment of H(Tl) vapour. Characterization of superconducting HTSC tape sample was carried out through XRD, TEM, SEM ...

  10. EPR and TL correlation in some powdered Greek white marbles

    Energy Technology Data Exchange (ETDEWEB)

    Baieetto, Vanessa E-mail: crpaa@montaigne.u-bordeaux.fr; Villeneuve, Gerard; Guibert, Pierre; Schvoerer, Max

    2000-02-01

    Thermoluminescence of white powdered marble samples, chosen to display different EPR spectra, were studied. Two peaks at 280 deg. C and 360 deg. C can be observed among the TL glow curves while the EPR spectra exhibit two signals: the A signal with g{sub perp}=2.0038 and g{sub par} =2.0024 due to the SO{sup -}{sub 3} centre and the B one with g{sub 1}=2.0005; g{sub 2}=2.0001; g{sub 3}=1.9998 due to mechanical powder reduction (drilling). Owing to heating and simultaneous experiments, a correlation have been established: the 280 deg. C TL peak is associated to the A signal and thus to the SO{sup -}{sub 3} centre and the 360 deg. C TL peak is caused by mechanical treatment corresponding to the B EPR signal.

  11. Pulsed laser deposition of Tl-Ca-Ba-Cu-O films

    International Nuclear Information System (INIS)

    Ianno, N.J.; Liou, S.H.; Woollam, J.A.; Thompson, D.; Johs, B.

    1990-01-01

    Pulsed laser deposition is a technique commonly used to deposit high quality thin films of high temperature superconductors. This paper discusses the results obtained when this technique is applied to the deposition of Tl-Ca-Ba-Cu-O thin films using a frequency doubled Nd:YAG laser operating at 532 nm and an excimer laser operating at 248 nm. Films with onset temperatures of 125 K and zero resistance temperatures of 110 K deposited on (100) oriented MgO from a composite Tl2Ca2Ba2Cu3Ox target were obtained at both wavelengths upon appropriate post deposition annealing. Films deposited at 532 nm exhibit a rough surface, while those deposited at 248 nm are smooth and homogeneous. Upon annealing, films deposited at both wavelengths are single phase Tl2Ca2Ba2Cu3Ox. 12 refs

  12. Development of a coincidence circuit with nanosecond resolving time for NaI(Tl) scintillator pulses

    International Nuclear Information System (INIS)

    Ripon, R.; Coussot, G.

    1969-01-01

    The principle and the details of a slow-fast type coincidence circuit for pulses delivered by Nal(Tl) scintillators are presented. Thanks to a voluntary limitation of the analysis band (150 keV to 1 MeV) an excellent stability is obtained with respect to thermal drifts. The resolving time which has been adopted, 4 ns with 100 per cent efficiency, is quite sufficient for the projected experiment but does not represent the optimum performance of which the circuit is capable [fr

  13. TL sensitivity of CaSO4:Dy phosphor powder - effect of grinding

    International Nuclear Information System (INIS)

    Shastry, S.S.; Kher, R.K.

    1979-01-01

    Grinding of polycrystalline CaSO 4 :Dy phosphor to powder form induces lattice defects. Changes in thermoluminescence (TL) sensitivity due to variation in trap density in the bulk and on the surface of phosphor grains are studied using gamma and UV radiations. TL sensitivity to gamma increases with grinding time due to the contribution from the new bulk traps which are generated by grinding. The surface traps degrade with increase in grinding time resulting in a decrease in UV sensitivity. Results on regeneration of the TL sensitivity due to annealing at different temperatures are also included. (Auth.)

  14. Persistent luminescence, TL and OSL characterization of beta irradiated SrAl{sub 2}O{sub 4}:Eu{sup 2+}, Dy{sup 3+} combustion synthesized phosphor

    Energy Technology Data Exchange (ETDEWEB)

    Zúñiga-Rivera, N.J. [Departamento de Física, Posgrado en Nanotecnología, Universidad de Sonora, Hermosillo, Sonora 83000 (Mexico); García, R.; Rodríguez-Mijangos, R.; Chernov, V.; Meléndrez, R.; Pedroza-Montero, M. [Departamento de Investigación en Física, Universidad de Sonora, Hermosillo, Sonora 83000 (Mexico); Barboza-Flores, M., E-mail: mbarboza@cifus.uson.mx [Departamento de Investigación en Física, Universidad de Sonora, Hermosillo, Sonora 83000 (Mexico)

    2014-05-01

    The persistent luminescence (PLUM), thermoluminescence (TL) and optically stimulated luminescence (OSL) properties of strontium aluminates co-doped with Eu{sup +2} and Dy{sup +3} exposed to beta radiation is reported. The phosphor was synthesized by the combustion synthesis method employing a highly exothermic redox reaction between the metal nitrates [Al(NO{sub 3}){sub 3}, Sr(NO{sub 3}){sub 2}, Eu(NO{sub 3}){sub 3} and Dy(NO{sub 3}){sub 3}] and organic fuel carbohydrazide (CH{sub 6}N{sub 4}O). The long decay PLUM emission, TL and OSL were measured as a function of beta radiation dose. A wide emission band centered at 510 nm (green) related to Eu{sup 2+} ions and lattice defects were observed for the synthesized samples. The presence of a variety of defects and aggregates were responsible for the observed broad 100 °C peaked TL glow curve of the irradiated sample which is composed of several overlapped TL peaks. The existence of multiple trapping levels, with different trapping/detrapping probabilities, is behind the particular features for the PLUM, TL and OSL emissions. We conclude that in the SrAl{sub 2}O{sub 4}:Eu{sup 2+}, Dy{sup 3+} phosphors, the low temperature TL peaked around 30–75 °C is responsible for the PLUM emission and those around 100 °C were related to very stable trapping states which provide suitable radiation storage properties to be used as a PLUM/TL/OSL radiation phosphor.

  15. Impact of intense x-ray pulses on a NaI(Tl)-based gamma camera

    NARCIS (Netherlands)

    Koppert, Wilco J C; van der Velden, Sandra; Steenbergen, J H Leo; de Jong, Hugo W A M

    2018-01-01

    INTRODUCTION: In SPECT/CT systems X-ray and -ray imaging is performed sequentially. Simultaneous acquisition may have advantages, for instance in interventional settings. However, this may expose a gamma camera to relatively high X-ray doses and deteriorate its functioning. We studied the NaI(Tl)

  16. Dopant concentration and thermoluminescence (TL) properties of tailor-made Ge-doped SiO2 fibres

    International Nuclear Information System (INIS)

    Zahaimi, Nurul Arina; Ooi Abdullah, Mohd Haris Ridzuan; Zin, Hafiz; Abdul Rahman, Ahmad Lutfi; Hashim, Suhairul; Saripan, Mohd Iqbal; Paul, Mukul Chandra; Bradley, D.A.; Abdul Rahman, Ahmad Taufek

    2014-01-01

    Study focuses on characterisation of diverse concentrations of Ge-doped SiO 2 fibre as a potential thermoluminescence (TL) system for radiotherapy dosimetry. Irradiations were made using a linear accelerator providing 6 MV and 10 MV photon beams. Investigation has been done on various doped core diameter Ge-doped SiO 2 glass fibres such as commercial telecommunication fibres of 8 µm and 9 µm (CorActive High Tech, Canada), tailor-made fibres of 23 and 50 µm produced by the Central Glass and Ceramic Research Institute Kolkata, and tailor-made fibres of 11 µm produced by the University of Malaya Photonics Research Centre. The fibres have been characterised for TL sensitivity, reproducibility, dose- and energy-dependence. The area under the TL glow curve increases with increasing core diameter. For repeat irradiations at a fixed dose the dosimeter produces a flat response better than 4% (1SD) of the mean of the TL distribution. Minimal TL signal fading was found, less than 0.5% per day post irradiation. Linearity of TL has been observed with a correlation coefficient (r 2 ) of better than 0.980 (at 95% confidence level). For particular dopant concentrations, the least square fits show the change in TL yield, in counts per second per unit mass, obtained from 50 µm core diameter fibres irradiated at 6 MV of photon to be 8 times greater than that of 8 µm core diameter fibre. With respect to energy response, the TL yield at 10 MV decreases by∼5% compared to that at 6 MV, primarily due to the lower mass energy absorption coefficient at higher photon energy. These early results indicate that selectively screened fibres can be developed into a promising TL system, offering high spatial resolution capability and, with this, verification of complex radiotherapy dose distributions. - Highlights: • We examined the TL glow curve intensity for various diameter sizes of germanium doped silica glass fibre. • TL sensitivity increased with the increase of fibre core

  17. Global parameterization and validation of a two-leaf light use efficiency model for predicting gross primary production across FLUXNET sites

    DEFF Research Database (Denmark)

    Zhou, Yanlian; Wu, Xiaocui; Ju, Weimin

    2015-01-01

    Light use efficiency (LUE) models are widely used to simulate gross primary production (GPP). However, the treatment of the plant canopy as a big leaf by these models can introduce large uncertainties in simulated GPP. Recently, a two-leaf light use efficiency (TL-LUE) model was developed...... to simulate GPP separately for sunlit and shaded leaves and has been shown to outperform the big-leaf MOD17 model at six FLUX sites in China. In this study we investigated the performance of the TL-LUE model for a wider range of biomes. For this we optimized the parameters and tested the TL-LUE model using...... data from 98 FLUXNET sites which are distributed across the globe. The results showed that the TL-LUE model performed in general better than the MOD17 model in simulating 8 day GPP. Optimized maximum light use efficiency of shaded leaves (epsilon(msh)) was 2.63 to 4.59 times that of sunlit leaves...

  18. Determination of kinetic parameters in Tl dosemeters of LiF: Mg, Cu, P + PTFE developed in the ININ

    International Nuclear Information System (INIS)

    Basurto G, B.S.

    2002-01-01

    The objective of this work, is the one of determining the kinetic parameters of the dosemeter of LiF: Mg, Cu, P + Ptfe; starting from the curves Tl obtained at being irradiated with alpha radiation (α), beta (β) and gamma (γ). As like to compare its sensitivity with each radiation type, considering the sensitivity of the TLD-100 as the unit. In the Chapter 1, the fundamental structure of the matter is described, making emphasis in the different radiation types, and their interaction with this. In the Chapter 2, the units are described but used in the dosimetry of the radiation. In the Chapter 3, the basic concepts of the phenomenon of Tl are described and those are explained characteristic of the deconvolution method to determine the kinetics of the one phenomenon. In the Chapter 4, the methodology is detailed that was used in the elaboration of this thesis work, describing the material Tl that were considered like reference, as well as the sources of ionizing radiation, with those that the dosemeters were irradiated and the equipment in the one that the curves Tl was obtained. Reference is made to the software used to carry out the deconvolution of the curves Tl that were obtained in the one experimental development. In the Chapter 5, the obtained results of this study are presented, showing the tables of homogenization of dosemeters and the reading of the same one; they are observed the curves Tl obtained to different radiation doses (alpha, beta and gamma), the intensity Tl in function of the dose. Also they are tabulated, the obtained results in the kinetic parameters of the three different study materials (TLD-100H, USA; TLD-100, USA and LiF: Mg, Cu, P + Ptfe developed in the l.N.l.N). They are analyzed shortly for each material Tl their sensitivity to the ionizing radiation as well as their kinetic parameters. The obtained results showed that the Tl dosemeters of LiF: Mg,Cu,P + Ptfe, they presented a bigger sensitivity that the TLD-100 when being

  19. The usefulness of [sup 201]TlCl scintigraphy for the diagnosis of breast tumor

    Energy Technology Data Exchange (ETDEWEB)

    Takahashi, Tamami; Moriya, Etsuo; Miyamoto, Yukio; Kawakami, Kenji; Kubo, Hirotaka; Uchida, Takeshi [Jikei Univ., Tokyo (Japan). School of Medicine

    1994-06-01

    The usefulness of [sup 201]TlCl SPECT (Tl SPECT) for the diagnosis of breast cancer was evaluated in 14 patients with various breast tumors (9 with invasive ductal carcinoma, 2 with fibroadenoma and 3 with benign process). These tumors ranged in size from 1.5 cm x 1.5 cm to 15.0 cm x 14.0 cm. Tl SPECT was carried out 2 hours after the intravenous injection of [sup 201]TlCl (185 MBq). For quantitative study, ROIs were set in the tumor (T), normal tissue of the opposite breast (B) and myocardium (M). Count ratios of T/B and T/M were calculated. Eight patients with breast cancer and a case of fibroadenoma showed intense accumulation of [sup 201]TlCl in the tumors. The T/B ratio was 1.20[+-]0.68 and the T/M ratio was 0.68[+-]0.31 in the 9 cases. Lymph node metastasis was detected in 2 of 6 cases that were confirmed at operation. No remarkable accumulation of [sup 201]TlCl was seen in 4 patients with benign process. One patient with benign tumor showed a false positive result. The rates of accuracy of mammography and ultrasonography for the same subjects were 82% and 84%, respectively. The results suggest that [sup 201]TlCl SPECT might be useful to assess breast cancer in cases in which the findings of other modalities are equivocal. (author).

  20. Challenges to Disciplinary Knowing and Identity: Experiences of Scholars in a SoTL Development Program

    Science.gov (United States)

    Miller-Young, Janice E.; Yeo, Michelle; Manarin, Karen

    2018-01-01

    Faculty members from five years of an annual Scholarship of Teaching and Learning (SoTL) development program were invited to participate in a study about the impact of SoTL on their teaching, scholarship, and career trajectory. During semi-structured interviews, many expressed feeling discomfort during their journey into SoTL. A qualitative…

  1. Factors which define the α/γ ratio in CsI:Tl crystals

    International Nuclear Information System (INIS)

    Kudin, Alexander M.; Sysoeva, Elena P.; Sysoeva, Elena V.; Trefilova, Larisa N.; Zosim, Dmitry I.

    2005-01-01

    Dependences of light yield and α/γ ratio on the Tl concentration have been studied within a wide range of shaping times. It is shown that the α/γ ratio essentially depends on the Tl concentration. Proper combination of the Tl concentration and optimum shaping time in electronics allows to obtain detectors with rather high light output for γ-rays, α-particles and α/γ ratio values. It has been shown that both the light yield at α-excitation and the α/γ-ratio depend on the time of crystal storage after polishing. On the basis of the idea of the formation of deformation-induced point defects in a thin surface-adjacent layer, the causes of the temporary increasing in light yield for α-particle are explained. An explanation is given of the results obtained by Gwin and Murray concerning the fact that the α/γ ratio is practically independent on Tl concentration

  2. The combined application of PIXE analysis and thermoluminescence (TL) dating for elucidating the origin of iron manufacturing in Japan

    International Nuclear Information System (INIS)

    Hagihara, N.; Miono, S.; Chengzhi, Z.; Nakayama, Y.; Hanamoto, K.; Manabe, S.

    1999-01-01

    For elucidating the origin of iron manufacturing in Japan, the usefulness of PIXE analysis was reconfirmed and a new technique of thermoluminescence (TL) dating was applied. Through reproducing experiments of iron manufacturing and forging, PIXE analysis was tested for classifying the iron slag produced from these two different process. The TL dating method was improved for experiments with the iron manufacturing furnace, burnt at high temperature (about 1300 K) and irradiated with relatively low dose. Utilizing PIXE analysis, the iron manufacturing furnace can be distinguished from the older forging furnace used for the imported iron plate. Adopting TL dating, the oldest iron manufacturing furnace can be found out. Some ancient samples in Japan were used as a test of this combined application, and the results were positive, thus proving the suitability of the method

  3. Enhanced thermoelectric figure of merit in strained Tl-doped Bi2Se3

    KAUST Repository

    Saeed, Y.; Singh, Nirpendra; Schwingenschlö gl, Udo

    2014-01-01

    We explain recent experimental findings on Tl-doped Bi2Se3 by determining the electronic and transport properties by first-principles calculations and semi-classical Boltzmann theory. Though Tl-doping introduces a momentum-dependent spin

  4. Lattice distortions in TlInSe{sub 2} thermoelectric material studied by X-ray absorption fine structure

    Energy Technology Data Exchange (ETDEWEB)

    Hosokawa, Shinya; Stellhorn, Jens Ruediger [Department of Physics, Kumamoto University, Kumamoto (Japan); Ikemoto, Hiroyuki [Department of Physics, University of Toyama, Toyama (Japan); Mimura, Kojiro [Department of Mathematical Sciences, Graduate School of Engineering, Osaka Prefecture University, Sakai (Japan); Wakita, Kazuki [Faculty of Engineering, Chiba Institute of Technology, Narashino (Japan); Mamedov, Nazim [Institute of Physics, Azerbaijan National Academy of Sciences, Baku (Azerbaijan)

    2018-01-15

    Tl L{sub II} and In K X-ray absorption fine structure (XAFS) measurements were performed on a TlInSe{sub 2} thermoelectric material in the temperature range of 25-300 K including the incommensurate-commensurate phase transition temperature of about 135 K. Most of the bond lengths obtained from the present XAFS measurements are in good agreement with existing X-ray diffraction data at room temperature, while only the Tl-Tl correlation shows inconsistent values indicating the commensurate properties of the Tl chains expected from the thermodynamic properties. The present XAFS data clearly support positional fluctuations of the Tl atoms found in three-dimensional atomic images reconstructed from X-ray fluorescence holography. (copyright 2017 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  5. Radiation Hardness Study of CsI(Tl) Crystals for Belle II Calorimeter

    CERN Document Server

    Matvienko, D V; Sedov, E V; Shwartz, B A

    2017-01-01

    The Belle II calorimeter (at least, its barrel part) consists of CsI(Tl) scintillation crystals which have been used at the Belle experiment. We perform the radiation hardness study of some typical Belle crystals and conclude their light output reductions are acceptable for Belle II experiment where the absorption dose can reach 10 krad during the detector operation. CsI(Tl) crystals have high stablity and low maintenance cost and are considered as possible option for the calorimeter of the future Super-Charm-Tau factory (SCT) in Novosibirsk. Our study demonstrates sufficiently high radiation hardness of CsI(Tl) crystals for SCT conditions.

  6. The influence of nanoscale heterostructures on the thermoelectric properties of bi-substituted Tl{sub 5}Te{sub 3}

    Energy Technology Data Exchange (ETDEWEB)

    Heinke, Frank; Schlegel, Robert; Schwarzmueller, Stefan; Oeckler, Oliver [Institute for Mineralogy, Crystallography, and Materials Science, Faculty of Chemistry and Mineralogy, Leipzig University (Germany); Eisenburger, Lucien [University of Munich (LMU), Department Chemie (Germany)

    2017-03-16

    Tl{sub 4.5}Bi{sub 0.5}Te{sub 3} crystallizes in a distorted variant of the Tl{sub 5}Te{sub 3} structure type in the space group I4/m. The symmetry reduction compared to Tl{sub 5}Te{sub 3} (space group I4/mcm) is a consequence of cation ordering as shown by resonant X-ray scattering using synchrotron radiation. Tl and Bi predominantly occupy one Wyckoff site each. This ordering is accompanied by displacements of Te atoms. The influence of nanostructuring on the thermoelectric performance of Tl{sub 4.5}Bi{sub 0.5}Te{sub 3} was investigated for the new composite model system Tl{sub 4.5}Bi{sub 0.5}Te{sub 3} - TlInTe{sub 2}. For the nominal composition (Tl{sub 4.5}Bi{sub 0.5}Te{sub 3}){sub 0.6}(TlInTe{sub 2}){sub 0.4}, the thermoelectric Figure of merit ZT reaches 0.8 at 325 C. Nanoscaled precipitates with sizes of about 100-200 nm probably have beneficial influence on the thermal conductivity at this temperature. (copyright 2017 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  7. 201Tl scintigraphy in the evaluation of palpable and nonpalpable breast lesions: correlation with mammography and ultrasonography

    International Nuclear Information System (INIS)

    Vural, G.; Atasever, T.; Oezdemir, A.; Oeznur, I.; Karabacak, N.I.; Goekcora, N.; Isik, S.; Uenlue, M.

    1997-01-01

    Tl-201 scintigraphy were performed in sixty-eight patients with 70 breast abnormalities (51 palpable, 19 nonpalpable) and compared with mammography and ultrasonography (US). Early (15 min) and late (3 h) images of the breasts were obtained following the injection of 111 MBq (3 mCi) of Tl-201. Visual and semiquantitative interpretation was performed. Final diagnosis confirmed 52 malignant breast lesions and 18 benign conditions. Tl-201 visualized 47 of 52 (90%) overall malignant lesions. Thirty-eight of 40 (95%) palpable and 9 of 12 (75%) nonpalpable breast cancers were detected by Tl-201 scintigraphy. The smallest mass lesion detected by Tl-201 measured 1.5x1.0 cm. Eleven breast lesions were interpreted as indeterminate by mammography and/or sonography. Tl-201 scintigraphy excluded malignancy in 7 of 8 (88%) patients with benign breast lesions interpreted as indeterminate. Five of the 18 (28%) benign breast lesions showed Tl-201 uptake. None of the fibroadenoma and fibrocystic changes accumulated Tl-201. Tl-201 scintigraphy, mammography and ultrasonography showed 90%, 92%, 85% overall sensitivity and 72%, 56%, 61% overall specificity respectively. Twenty-one of the 28 (75%) axillary nodal metastatic sites were also detected by Tl-201. In malignant and benign lesions, early and late lesion/contralateral normal side (L/N) ratios were 1.58±0.38 (mean±SD) and 1.48±0.32 (p>0.05), 1.87±0.65 and 1.34±0.20 (p 0.05). (orig./MG) [de

  8. Activation analysis of thallium by /sup 203/Tl(n,2n)/sup 202/Tl reaction in nuclear reactors

    Energy Technology Data Exchange (ETDEWEB)

    Cohen, I M; Resnizky, S M; Baro, G B [Comision Nacional de Energia Atomica, Buenos Aires (Argentina). Gerencia de Radioisotopos y Radiaciones

    1982-01-01

    Two techniques are described for neutron activation analysis of thallium in biological and geological materials, based on /sup 203/Tl(n,2n)/sup 202/Tl reaction in nuclear reactors. Co-precipitation with bismuth sulphide is used as a pre-concentration method of thallium in urine samples, and post-irradiation chemical separation is also performed. The detection limit is 0.5 ..mu..g/l, for 100 ml urine samples. For thallium determination in blendes a radiochemical separation is carried out after the irradiation. An extension of this technique is presented for glass and silicate rocks. Results for seven blende samples from different places of Argentina are shown. Analysis of two reference materials, the 614 glass from the National Bureau of Standards and the granodiorite GSP-1 from the U.S. Geological Survey were also performed. The results are in very good agreement with the certified or estimated values.

  9. Disquisition and technical alteration about TL apparatus

    International Nuclear Information System (INIS)

    Wang Guangxiang; Li Mingliang

    2002-01-01

    The author simply introduces the disadvantage of TL apparatus controlled by single chip. The project uses the PC computer to replace single chip control. So it must be changed the interface and made up a software with Chinese

  10. Superdeformation in the Hg-Tl-Pb region

    International Nuclear Information System (INIS)

    Henry, E.A.; Becker, J.A.; Yates, S.W.; Wang, T.F.; Kuhnert, A.; Brinkman, M.J.; Cizewski, J.A.; Deleplanque, M.A.; Diamond, R.M.; Stephens, F.S.; Azaiez, F.; Korten, W.; Draper, J.E.

    1990-10-01

    Superdeformation in the Hg-Tl-Pb region is discussed, with concentration on the experimental results. At least twenty-five superdeformed bands are known in this region, providing much new data to test theoretical calculations. 22 refs., 5 figs

  11. Evaluation of /sup 201/TlCl and delayed scan for thyroid imaging agent

    Energy Technology Data Exchange (ETDEWEB)

    Taniguchi, Tatsuyoshi; Harada, Taneichi; Takahashi, Tatsuo; Senoo, Tsuneaki; Ohtsuka, Nobuaki; Ito, Yasuhiko [Kawasaki Medical School, Kurashiki, Okayama (Japan)

    1982-11-01

    The results of 189 patients with nodular goiter by imaging with /sup 201/TlCl following with sup(99m)TcO/sub 4//sup -/ was presented. Accumulation of /sup 201/TlCl to the corresponding area was observed in 85.5% of cancer, 62.2% of adenoma, 42.5% of adenomatous goiter, and the usefulness of /sup 201/TlCl (early scan) for thyroid imaging agent was recognized. On the other hand, delayed scan for purpose of differentiation from benign to malignant was also performed. However, no significant differences were obtained.

  12. Intercomparison of Environmental Dosemeters Using Various TL Materials and Dosimetry Systems

    International Nuclear Information System (INIS)

    Crnic, B.; Gobec, S.; Zorko, B.; Knezevic, Z.; Majer, M.; Ranogajec-Komor, M.

    2013-01-01

    The aim of the present work was to compare the ambient dose equivalent (H*(10)) values determined at 20 sites around NPP Krško, using different thermoluminescence (TL) materials and various dosimetry systems. The H*(10) was measured by the CaF 2 :Mn (TLD-400) provided by the Jozef Stefan Institute (JSI) Ljubljana, Slovenia. These dosemeters were deployed in the environment in plastic bags and suspended inside the plastic bottles. On the other hand the Ruder Boskovic Institute (RBI), Zagreb, Croatia applied LiF:Mg,Cu,P (TLD-100H), CaF 2 :Mn, Al 2 O 3 :C TL detectors and radiophotoluminescence (RPL) glass dosemeters type SG1. They were placed at the same locations in as much as possible same conditions as JSI detectors. According to the protocol established for this intercomparison, the control and transport detectors (not deployed in the environment) were held in dark storage containers and used to determine the background radiation. The TL responses were corrected for individual sensitivity of the TL detectors which is an important factor after the calibration irradiations. The calibration irradiations were performed by 137Cs sources provided in Secondary Standard Dosimetry Laboratory facilities at the JSI and RBI. The results obtained by different TL materials and different dosimetry systems show interesting features especially concerning local environmental peculiarities. The H*(10) obtained by the dosemeters of various types deployed in the countryside fluctuate less than 10 %. The outcome should emphasize also in the manner that the results obtained and reported in the intercomparison are traceable to the primary standards.(author)

  13. Program for the evaluation of TL-brick dating: 'ADAM-1-EVA'

    International Nuclear Information System (INIS)

    Novotna, V.; Kubelik, M.; Musilek, L.

    2000-01-01

    Although the evaluation of the TL-mean date has presented very little diversity since first published, the error evaluation has prompted a lot of discussion. Particularly the physical, chemical, statistical and mathematical differences as reflected in the specifics of the evaluation of the individual random and systematic errors in ceramic and brick dating are undervalued in literature. The construction of an automated TL-Reader (ADAM-1) at the Czech Technical University in Prague was taken as an opportunity to create a whole new software package for the evaluation ('EVA') of TL-dates. ADAM-1 is designed primarily for brick dating, using the fine-grain technique. The philosophy of data processing is similar to that applied by the Berlin group in their research of Venetian Villas. The program was developed using Delphi, as it is user-friendlier than pure Pascal, offers a strong graphic platform and allows flexibility in data management. This was important, as the program was conceived to either interact directly with ADAM-1, or to be operated independently for data evaluation and management. The software package consists of two discrete yet combinable components: one for the calculation of the TL mean date, using all raw data obtained from ADAM-1 and peripheral measurements; the other for the evaluation of systematic, random and context errors of individual samples and sample groups. All steps in the calculations are also graphically available, e.g. glow curves, plateau test, TL vs. dose dependence and charts summarising the results of all calculations for an individual sample and a given context. (author)

  14. Usefulness of 201Tl myocardial scintigraphy after dipyridamole infusion in patients with atherosclerotic vascular disease

    International Nuclear Information System (INIS)

    Toyama, Takuji; Nishimura, Tsunehiko; Uehara, Toshiisa

    1992-01-01

    To determine the utility for detecting ischemic heart disease (IHD), dipyridamole thallium myocardial images (DIP-Tl) have been performed in 103 patients with atherosclerotic vascular disease who can't exercise fully. Of the 103 patients, there were 36 patients with arteriosclerosis obliterans (ASO), 31 patients with aneurysm of the abdominal aorta (AAA), 24 patients with aneurysm of the thoracic aorta (TAA) and 12 patients with dissecting aortic aneurysm (DAA). Clinical evidence of IHD was found in 20 patients with ASO, 10 with AAA, 7 with TAA and 4 with DAA. Positive evidence of DIP-Tl was identified in 66% of 41 patients who had clinical evidence of IHD, and particularly in the patients with AAA (80%) and ASO (65%). On the other hand, in the patients without clinical evidence of IHD, positive evidence of DIP-Tl was identified in 19% of 62 patients and particularly in the patients with AAA (39%). In all patients, the percentage of the positive DIP-Tl ratio was 38%. And, when the 38% patients of the positive DIP-Tl were added to the patients of the negative DIP-Tl who had clinical evidence of IHD, almost half patients (51%) were considered to be complicated with IHD. This study suggests that the atherosclerotic vascular disease is highly complicated with IHD and DIP-Tl is useful to detect IHD. (author)

  15. SCOPE-mTL: A non-invasive tool for identifying and lateralizing mesial temporal lobe seizures prior to scalp EEG ictal onset.

    Science.gov (United States)

    Lam, Alice D; Maus, Douglas; Zafar, Sahar F; Cole, Andrew J; Cash, Sydney S

    2017-09-01

    In mesial temporal lobe (mTL) epilepsy, seizure onset can precede the appearance of a scalp EEG ictal pattern by many seconds. The ability to identify this early, occult mTL seizure activity could improve lateralization and localization of mTL seizures on scalp EEG. Using scalp EEG spectral features and machine learning approaches on a dataset of combined scalp EEG and foramen ovale electrode recordings in patients with mTL epilepsy, we developed an algorithm, SCOPE-mTL, to detect and lateralize early, occult mTL seizure activity, prior to the appearance of a scalp EEG ictal pattern. Using SCOPE-mTL, 73% of seizures with occult mTL onset were identified as such, and no seizures that lacked an occult mTL onset were identified as having one. Predicted mTL seizure onset times were highly correlated with actual mTL seizure onset times (r=0.69). 50% of seizures with early mTL onset were lateralizable prior to scalp ictal onset, with 94% accuracy. SCOPE-mTL can identify and lateralize mTL seizures prior to scalp EEG ictal onset, with high sensitivity, specificity, and accuracy. Quantitative analysis of scalp EEG can provide important information about mTL seizures, even in the absence of a visible scalp EEG ictal correlate. Copyright © 2017 International Federation of Clinical Neurophysiology. Published by Elsevier B.V. All rights reserved.

  16. A portable in situ NaI(Tl) γ spectroscopy system

    International Nuclear Information System (INIS)

    Wang Bairong; Dong Binjiang; Zeng Liping

    1999-01-01

    The author describes a portable in situ NaI(Tl) γ spectroscopy system, which consists of a NaI(Tl) scintillation detector, an integrative spectroscopy card, a notebook computer and the spectroscopy software. The spectrometer addresses applications in environmental or nuclear accident in situ γ spectroscopy measurements, and gives valid quantitative results of radionuclide concentrations per unit volume (Bq/kg) or per unit area (Bq/cm 2 ) in the soil and absorbed dose rate in air 1 m above ground (Gy/h)

  17. Evaluation of myocardial disorders in patients with dilated cardiomyopathy and left ventricular eccentric hypertrophy; By sup 201 Tl myocardial SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Yamazaki, Junichi; Ohsawa, Hidefumi; Uchi, Takashi (Toho Univ., Tokyo (Japan). School of Medicine) (and others)

    1992-03-01

    {sup 201}Tl myocardial SPECT was performed in cases of dilated cardiomyopathy and valvular heart disease with left ventricular eccentric hypertrophy, and the two groups were compared from the standpoint of the mechanism of onset of myocardial disorders. Significant coefficients of correlation were seen between the Tl score and LVDd (r=0.792, r=0.785) and Tl score and LVEF (r=-0.634, r=-0.555) in both dilated cardiomyopathy and valvular heart disease. In cases of valvular heart disease, significant correlation coefficients (r=-0.756, r=-0.720) between LVDd and r-WR (relative-washout rate), and Tl score and r-WR were observed, but no such correlation was seen in dilated cardiomyopathy. In valvular heart disease, a decrease in myocardial perfusion associated with enlargement of the left ventricle appeared, while in dilated cardiomyopathy, there was a marked decrease in LVEF in proportion to the thallium defect. Therefore, it was assumed that left ventricular wall disorders occur due to myocardial metabolic disorders and coronary microcirculation disorders. (author).

  18. Binuclear Pt-Tl bonded complex with square pyramidal coordination around Pt: a combined multinuclear NMR, EXAFS, UV-Vis, and DFT/TDDFT study in dimethylsulfoxide solution.

    Science.gov (United States)

    Purgel, Mihály; Maliarik, Mikhail; Glaser, Julius; Platas-Iglesias, Carlos; Persson, Ingmar; Tóth, Imre

    2011-07-04

    the (CN)(4)Pt-Tl(dmso)(5)(+) system by using DFT calculations (B3LYP model) provide bond distances in excellent agreement with the EXAFS data. The four cyanide ligands are located in a square around the Pt atom, while the Tl atom is coordinated in a distorted octahedral fashion with the metal being located 0.40 Å above the equatorial plane described by four oxygen atoms of dmso ligands. The four equatorial Tl-O bonds and the four cyano ligands around the Pt atom are arranged in an alternate geometry. The coordination environment around Pt may be considered as being square pyramidal, where the apical position is occupied by the Tl atom. The optimized geometry of (CN)(4)Pt-Tl(dmso)(5)(+) is asymmetrical (C(1) point group). This low symmetry might be responsible for the unusually large NMR linewidths observed due to intramolecular chemical exchange processes. The nature of the Pt-Tl bond has been studied by MO analysis. The metal-metal bond formation in (CN)(4)Pt-Tl(dmso)(5)(+) can be simply interpreted as the result of a Pt(5d(z(2)))(2) → Tl(6s)(0) donation. This bonding scheme may rationalize the smaller thermodynamic stability of this adduct compared to the related complexes with (CN)(5)Pt-Tl entity, where the linear C-Pt-Tl unit constitutes a very stable bonding system. © 2011 American Chemical Society

  19. The effects of chemical and radioactive properties of Tl-201 on human erythrocyte glucose 6-phosphate dehydrogenase activity

    International Nuclear Information System (INIS)

    Sahin, Ali; Senturk, Murat; Ciftci, Mehmet; Varoglu, Erhan; Kufrevioglu, Omer Irfan

    2010-01-01

    Aim: The inhibitory effects of thallium-201 ( 201 Tl) solution on human erythrocyte glucose 6-phosphate dehydrogenase (G6PD) activity were investigated. Methods: For this purpose, erythrocyte G6PD was initially purified 835-fold at a yield of 41.7% using 2',5'-Adenosine diphosphate sepharose 4B affinity gel chromatography. The purification was monitored by sodium dodecyl sulfate-polyacrylamide gel electrophoresis, which showed a single band for the final enzyme preparation. The in vitro and in vivo effects of the 201 Tl solution including Tl + , Fe +3 and Cu +2 metals and the in vitro effects of the radiation effect of the 201 Tl solution and non-radioactive Tl + , Fe +3 and Cu +2 metals on human erythrocyte G6PD enzyme were studied. Enzyme activity was determined with the Beutler method at 340 nm using a spectrophotometer. All purification procedures were carried out at +4 deg. C. Results: 201 Tl solution and radiation exposure had inhibitory effects on the enzyme activity. IC 50 value of 201 Tl solution was 36.86 μl ([Tl + ]: 0.0036 μM, [Cu +2 ]: 0.0116 μM, [Fe +3 ]: 0.0132 μM), of human erythrocytes G6PD. Seven human patients were also used for in vivo studies of 201 Tl solution. Furthermore, non-radioactive Tl + , Fe +3 and Cu +2 were found not to have influenced the enzyme in vitro. Conclusion: Human erythrocyte G6PD activity was inhibited by exposure for up to 10 minutes to 0.057 mCi/kg 201 Tl solution. It was detected in in vitro and in vivo studies that the human erythrocyte G6PD enzyme is inhibited due to the radiation effect of 201 Tl solution.

  20. Morphometric relations in the grey eel catfish Plotosus canius in the coastal waters of Port Dickson, Peninsular Malaysia.

    Science.gov (United States)

    Usman, B I; Amin, S M N; Arshad, A; Kamarudin, M S

    2016-07-01

    Samples of grey eel catfish Plotosus canius were collected from the coastal waters of Port Dickson, Malaysia from January to December, 2012. A total of 341 specimens (172 males and 169 females) were used to estimate the length-weight relationship parameters. Mean population size of females were 0.72 cm taller than the males, however difference was not significant (t-test, P > 0.05). The overall relationship equations between total length (TL) and body weight (BW) were established for males as Log TW = 2.71 Log TL - 1.85 (R2 = 0.95) and for females as Log TW = 2.88 Log TL-2.10 (R2 = 0.95). The estimated relative growth co-efficient (b) values were 2.71 for males and 2.88 for females. It is revealed that growth pattern of the species showed negative allometry. In both males and females, relationship between TL and SL gave highest regression coefficient (0.99). While relationship between TL and EL gave lowest regression coefficient in both males and females (0.87 and 0.81 respectively). The findings from this study contributed first information on morphometric relations of the fish from Malaysian coastal waters and could be useful for sustainable management options of P. canius in Malaysia.

  1. Characteristics of dielectric properties and conduction mechanism of TlInS2:Cu single crystals

    Science.gov (United States)

    El-Nahass, M. M.; Ali, H. A. M.; El-Zaidia, E. F. M.

    2013-12-01

    Single crystals of TlInS2:Cu were grown by the modified Bridgman method. The dielectric behavior of TlInS2:Cu was investigated using the impedance spectroscopy technique. The real (ε1), imaginary (ε2) parts of complex dielectric permittivity and ac conductivity were measured in the frequency range (42-2×105) Hz with a variation of temperature in the range from 291 K to 483 K. The impedance data were presented in Nyquist diagrams for different temperatures. The frequency dependence of σtot (ω) follows the Jonscher's universal dynamic law with the relation σtot (ω)=σdc+Aωs, (where s is the frequency exponent). The mechanism of the ac charge transport across the layers of TlInS2:Cu single crystals was referred to the hopping over localized states near the Fermi level. The examined system exhibits temperature dependence of σac (ω), which showed a linear increase with the increase in temperature at different frequencies. Some parameters were calculated as: the density of localized states near the Fermi level, NF, the average time of charge carrier hopping between localized states, τ, and the average hopping distance, R.

  2. Structural behavior of Tl-exchanged natrolite at high pressure depending on the composition of pressure-transmitting medium

    Science.gov (United States)

    Seryotkin, Yu. V.; Bakakin, V. V.; Likhacheva, A. Yu.; Dementiev, S. N.; Rashchenko, S. V.

    2017-10-01

    The structural evolution of Tl-exchanged natrolite with idealized formula Tl2[Al2Si3O10]·2H2O, compressed in penetrating (water:ethanol 1:1) and non-penetrating (paraffin) media, was studied up to 4 GPa. The presence of Tl+ with non-bonded electron lone pairs, which can be either stereo-chemically active or passive, determines distinctive features of the high-pressure behavior of the Tl-form. The effective volume of assemblages Tl+(O,H2O) n depends on the E-pairs activity: single-sided coordination correlates with smaller volumes. At ambient conditions, there are two types of Tl positions, only one of them having a nearly single-sided coordination as a characteristic of stereo-activity of the Tl+ E pair. Upon the compression in paraffin, a phase transition occurs: a 5% volume contraction of flexible natrolite framework is accompanied by the conversion of all the Tl+ cations into stereo-chemically active state with a single-sided coordination. This effect requires the reconstruction of all the extra-framework subsystems with the inversion of the cation and H2O positions. The compression in water-containing medium leads to the increase of H2O content up to three molecules pfu through the filling of partly vacant positions. This hinders a single-sided coordination of Tl ions and preserves the configuration of their ion-molecular subsystem. It is likely that the extra-framework subsystem is responsible for the super-structure modulation.

  3. Streptomyces venezuelae TX-TL - a next generation cell-free synthetic biology tool.

    Science.gov (United States)

    Moore, Simon J; Lai, Hung-En; Needham, Hannah; Polizzi, Karen M; Freemont, Paul S

    2017-04-01

    Streptomyces venezuelae is a promising chassis in synthetic biology for fine chemical and secondary metabolite pathway engineering. The potential of S. venezuelae could be further realized by expanding its capability with the introduction of its own in vitro transcription-translation (TX-TL) system. TX-TL is a fast and expanding technology for bottom-up design of complex gene expression tools, biosensors and protein manufacturing. Herein, we introduce a S. venezuelae TX-TL platform by reporting a streamlined protocol for cell-extract preparation, demonstrating high-yield synthesis of a codon-optimized sfGFP reporter and the prototyping of a synthetic tetracycline-inducible promoter in S. venezuelae TX-TL based on the tetO-TetR repressor system. The aim of this system is to provide a host for the homologous production of exotic enzymes from Actinobacteria secondary metabolism in vitro. As an example, the authors demonstrate the soluble synthesis of a selection of enzymes (12-70 kDa) from the Streptomyces rimosus oxytetracycline pathway. © 2017 The Authors. Biotechnology Journal published by WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. TL/OSL properties of natural schist for archaeological dating and retrospective dosimetry

    International Nuclear Information System (INIS)

    Afouxenidis, D.; Stefanaki, E.C.; Polymeris, G.S.; Sakalis, A.; Tsirliganis, N.C.; Kitis, G.

    2007-01-01

    Schist, a metamorphic rock composed largely of quartz and muscovite, has been used as a building stone through the centuries in many parts of the world. In ancient Greece, it was used in buildings and monuments (Knossos, Karthaia, etc). Basic TL and OSL properties of schist are studied in the present work to evaluate its potential use in archaeological dating and retrospective dosimetry. In particular, the optical stability, as well as the linearity of the TL and OSL signal were investigated for samples of natural schist obtained from a roofing slate. The results indicate that both signals are rapidly bleached when the sample is exposed to sunlight. An exposure of 1 min reduces the TL signal by 93%, the IRSL signal by 99% and the post-IR BSL signal by 90%. The dose response was found to be linear for a radiation dose at least up to 75 Gy for the TL and the IR OSL signal and at least up to 25 Gy for the post-IR BSL signal

  5. Effects of industrial by-product amendments on As, Cd and Tl retention/release in an element-spiked acidic soil

    International Nuclear Information System (INIS)

    Aguilar-Carrillo, Javier; Barrios, Laura; Garrido, Fernando; Garcia-Gonzalez, Maria Teresa

    2007-01-01

    To asses the efficiency of two by-products (phosphogypsum (PG) and sugar foam (SF), rich in gypsum and calcium carbonate, respectively) in the immobilization of three toxic elements (As, Cd and Tl) in an acidic soil, batch-scale sorption and desorption experiments were conducted after 18 months of in situ amendment application. The Langmuir isotherms applied for sorption studies showed that the estimated maximum sorption capacity of the elements was highest in the SF-treated samples. The amount of element retained and the percentage of extraction after TCLP tests indicated that those samples amended with sugar foam (SF and PG + SF) had the potential to immobilize As, Cd and Tl in an acidic soil with low sorptive capacity. In addition to sorption and desorption experiments, scanning electron microscopy in back-scattered electron mode (SEM-BSE) showed the formation of Al-hydroxy polymers which provides the soil with additional sorption capacity. The three target elements were associated with the Al-hydroxy polymers, probably through direct coordination or the formation of ternary complexes. By means of statistical analysis it has been found that sorption processes of As, Cd and Tl in this soil mainly depend on the treatment, whereas desorption is an element-dependent process

  6. Assessment of vascularity and permeability in brain tumor using SPECT and [sup 99m]Tc-DTPA-human serum albumin in relation to [sup 201]Tl SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Nakagawara, Jyoji; Fukuoka, Seiji; Takahashi, Shuhei; Takahashi, Masaaki; Satoh, Katsuyasu; Suematsu, Katsumi; Nakamura, Jun-ichi (Nakamura Memorial Hospital, Sapporo (Japan))

    1994-02-01

    Single photon emission computed tomography (SPECT) using technetium-99m-DTPA-human serum albumin ([sup 99m]Tc-HSA-D) and thallium-201 chloride ([sup 201]Tl) was simultaneously performed on 25 patients with brain tumors; 10 with brain metastasis, 8 with astrocytoma (Gr. 3) and 7 with meningioma. The early image was obtained 10 minutes after [sup 99m]Tc-HSA-D (740 MBq) injection, and the delayed image was taken 5 hours after the injection. HSA-D index, based on the ratio of [sup 99m]Tc-HSA-D uptake in the tumor versus the cortical area, was calculated on each image, and compared with Tl index (tumor/contralateral cerebrum ratio). HSA-D delayed index was significantly greater than HSA-D early index in all tumor types (p<0.05 by the Wilcoxon ranked sign test). Linear correlation between HSA-D early index and HSA-D delayed index was significant in astrocytoma (GR. 3) (p<0.01) and meningioma (p<0.001), and a linear correlation between HSA-D delayed index and Tl index was significant in astrocytoma (Gr. 3) (p<0.05). It is concluded that HSA-D early index and delayed index could reflect tumor vascularity and permeability, respectively, and provide supplementary information for Tl index. (author).

  7. Calculated energy dependence of CaSO4:Dy TL phosphor and phosphor embedded Teflon for X and gamma rays

    International Nuclear Information System (INIS)

    Chang, J.-K.; Nam, Y.-M.; Kim, J.-L.; Chang, S.-Y.; Kim, B.-H.

    2001-01-01

    The energy dependence of a CaSO 4 :Dy TL phosphor for 21 monoenergetic photons of energy ranging from 0.01 to 3 MeV was calculated by using MCNP4A code. The calculation results show good agreement with those of other authors within ± 5% relative error. Calculations and experiments are also performed to determine the energy dependence of CaSO 4 : Dy phosphor with Dy concentrations from 0.01 to 1.5 mol %, and with the compositions of TL-Teflon from 10 to 90 wt %. The calculated energy responses show good agreement with the experiment results within ± 20% relative error except for a concentration lower than 0.1 mol % Dy and the low energy regions of M30 (Eave.=20 keV) and M60 (Eave.=34 keV). For the TL-Teflon mixture, the energy dependence shows an decreasing trend with the increase of Teflon concentration in MCNP calculation but shows no dependence for TL-Teflon mixture proportions in experiment. These differences are due to the non-homogeneous distribution of Dy concentration and the effect of large grain size in the phosphors. The energy dependence of the 30 wt/o CaSO 4 (0.1 mol%;Dy) and 70 wt/o Teflon that is placed behind the filters of plastic, aluminum, copper, tin and lead with a thickness from 0.1 to 2 mm were calculated, respectively

  8. Prediction of improvement of myocardial wall motion after coronary artery bypass surgery using rest Tl-201/dipyridamole stress gated Tc-99m-MIBI/24 hour delay Tl-201 SPECT

    International Nuclear Information System (INIS)

    Lee, Dong Soo; Lee, Won Woo; Yeo, Jeong Yeo; Kim, Seok Ki; Kim, Ki Bong; Chung, June Key; Lee, Myung Chul

    1998-01-01

    Using rest Tl-201/ dipyridamole stress gated Tc-99m-MIBI/24 hour delay Tl-201 SPECT, we investigated the predictive values of the markers of the stress-rest reversibility (Rev), Tl-201 rest perfusion (Rest), Tl-201 24 hour redistribution (Del) and Tc-99m-MIBI gated systolic thickening (Thk) for wall motion improvement after coronary artery bypass surgery. In 39 patients (M:F=34:5, age 58±8), preoperative and postoperative (3 months) SPECT were compared. 24 hour delayed SPECT was done in 16 patients having perfusion defects at rest. Perfusion or wall motion was scored from 0 to 3 (0: normal to 3: defect or dyskinesia). Wall motion was abnormal in 142 segments among 585 segments of 99 artery territories which were surgically revascularized. After bypass surgery, ejection fraction increased from 37.8±9.0% to 45.5±12.3% in 22 patients who had decreased ejectin fraction preoperatively. Wall motion improved in 103 (72.5%) segments among 142 dysfunctional segments. Positive predictive values (PPV) of Rev, Rest, Del, and Thk were 83%, 76%, 43%, and 69% respectively. Negative predictive values (NPV) of Rev, Rest, Del, and Thk were 48%, 44%, 58%, and 21%, respectively. Rest/gated stress/delay SPECT had PPV of 74% and NPV of 46%. Through univariate logistic regression analysis revealed Rev( p=0.0008) and Rest (p=0.024) as significant predictors, stepwise multivariate test found Rev as the only good predictor (p=0.0008). Among independent predictors obtained by rest Tl-201/stress gated Tc-99m-MIBI/delayed Tl-201 myocardial SPECT for wall motion improvement after bypass surgery, stress-rest reversibility was the single most useful predictor

  9. Quantitative evaluation of right ventricular overload in cor pulmonale using 201Tl myocardial SPECT

    International Nuclear Information System (INIS)

    Kato, Hiroshi; Misawa, Toshihiro; Kutsumi, Yasunori

    1991-01-01

    To determine quantitatively the discriminant and characteristics of cor pulmonale, 201 Tl myocardial perfusion SPECT was performed in 16 patients with chronic obstructive pulmonary disease (COPD) and 7 with restrictive pulmonary disease (RPD). One section of the short-axis SPECT image in which the right ventricle was most clearly visualized was selected. Tl-score was defined as the ratio of the sum of counts in the region of interest (ROI) at the anterior, mid, and posterior regions of the right ventricular free wall to the sum of counts in ROI at the posterior, lateral, and anterior walls of the left ventricle, and the anterior and posterior regions of the interventricular septum. In the group of COPD patients, Tl-score was positively correlated with mean pulmonary arterial pressure (mPAP), total pulmonary vascular resistance (TPR), and arterial carbon dioxide tension (PaCO 2 ), while it was inversely correlated with arterial oxygen tension (PaO 2 ). However, there was no significant correlation between Tl-score and mPAP, TPR, PaCO 2 , and PaO 2 in the group of RPD patients. In assessing pulmonary hypertension as defined by mPAP over 20 mmHg, a Tl-score greater than 0.25 was useful with a sensitivity of 69% and a specificity of 90%. The occurrence of cor pulmonale is a major factor in determining the prognosis of COPD patients. It was concluded that 201 Tl myocardial SPECT is useful for evaluating right ventricular overload quantitatively, as well as for assessing core pulmonale, especially in COPD patients, since the ratio of Tl counts in the right and left ventricles was significantly correlated with right cardiopulmonary hemodynamic parameters. (N.K.)

  10. Effects of cross talk on dual energy SPECT imaging between 123I-BMIPP and 201Tl

    International Nuclear Information System (INIS)

    Morita, Masato; Narita, Hitoshi; Yamamoto, Juro; Fukutake, Naoshige; Ohyanagi, Mitsumasa; Iwasaki, Tadaaki; Fukuchi, Minoru

    1994-01-01

    The study was undertaken to determine how much cross talk influences the visual assessment of dual energy single photon emission computed tomographic (SPECT) images with iodine 123 beta-methyl-p-iodophenylpentadecanoic acid (I-123 BMIPP) and thallium-201 in 15 patients with acute myocardial infarction. After single SPECT with I-123 BMIPP was undertaken, simultaneous dual SPECT with I-123 BMIPP and Tl-201 were undertaken in all patients. Three patients also underwent single SPECT with Tl-201. I-123 BMIPP and Tl-201 uptake was graded in four-score for the comparison between single and dual SPECT images. There was good correlation between dual energy SPECT and both single I-123 BMIPP SPECT (pS=0.97) and single Tl-201 SPECT (pS=0.59). Uptake scores were increased on dual energy SPECT, compared with single I-123 SPECT (8 out of 132 segments) and single Tl-201 SPECT (12 out of 36 segments). Overall, there was a comparatively well correlation between single SEPCT with either I-123 BMIPP or Tl-201 and dual energy SPECT images. However, one tracer uptake sometimes increased in the other tracer defect areas. This was noticeable when I-123 BMIPP exerted an effect on Tl-201. (N.K.)

  11. Study of multi-quasiparticle band structures in 197Tl using α beam

    International Nuclear Information System (INIS)

    Mukherjee, G.; Nandi, S.; Pai, H.

    2016-01-01

    Study of the multi-quasiparticle (qp) states and the band structures built on them in the neutron deficient Tl nuclei in A ∼ 190 mass region provides useful information on particle-hole interaction in the heavy nuclei. In order to investigate the multi-qp band structures we have studied the excited states in 197 Tl by gamma ray spectroscopy

  12. Tumor and infection localization in AIDS patients: Ga-67 and Tl-201 findings.

    Science.gov (United States)

    Turoglu, H T; Akisik, M F; Naddaf, S Y; Omar, W S; Kempf, J S; Abdel-Dayem, H M

    1998-07-01

    Examples of Ga-67 and Tl-201 scans in AIDS patients performed at St. Vincent's Hospital and Medical Center of New York are presented. Use of these methods is the adopted approach at this institution in AIDS patients for localizing sites of tumor or infection involvement. A Ga-67 scan is the most common nuclear medicine examination performed on AIDS patients. Sequential Tl-201 and Ga-67 scans have a role in differentiating Kaposi's sarcoma from malignant lymphoma and opportunistic infections. For intracranial lesions, Tc-99m MIBI or Tl-201-201-201-201 chloride can differentiate malignant from benign inflammatory lesions.

  13. Tl{sub 10}Hg{sub 3}Cl{sub 16}: Single crystal growth, electronic structure and piezoelectric properties

    Energy Technology Data Exchange (ETDEWEB)

    Khyzhun, O.Y., E-mail: khyzhun@ipms.kiev.ua [Frantsevych Institute for Problems of Materials Science, National Academy of Sciences of Ukraine, 3 Krzhyzhanivsky Street, 03142 Kyiv (Ukraine); Piasecki, M. [Institute of Physics, J.Dlugosz University Częstochowa, Armii Krajowej 13/15, Częstochowa PL-42-217 (Poland); Kityk, I.V. [Electrical Engineering Department, Częstochowa University Technology, Armii Krajowej 17, PL-42-200 Częstochowa (Poland); Luzhnyi, I. [Frantsevych Institute for Problems of Materials Science, National Academy of Sciences of Ukraine, 3 Krzhyzhanivsky Street, 03142 Kyiv (Ukraine); Fedorchuk, A.O. [Department of Inorganic and Organic Chemistry, Lviv National University of Veterinary Medicine and Biotechnologies, 50 Pekarska Street, 79010 Lviv (Ukraine); Fochuk, P.M. [Yuriy Fed’kovych Chernivtsi National University, 2 Kotziubynskoho Street, 58012 Chernivtsi (Ukraine); Levkovets, S.I. [Department of Inorganic and Physical Chemistry, Lesya Ukrainka Eastern European National University, 13 Voli Avenue, 43025 Lutsk (Ukraine); Karpets, M.V. [Frantsevych Institute for Problems of Materials Science, National Academy of Sciences of Ukraine, 3 Krzhyzhanivsky Street, 03142 Kyiv (Ukraine); Parasyuk, O.V. [Department of Inorganic and Physical Chemistry, Lesya Ukrainka Eastern European National University, 13 Voli Avenue, 43025 Lutsk (Ukraine)

    2016-10-15

    Single crystal of the ternary halide Tl{sub 10}Hg{sub 3}Cl{sub 16} was grown using Bridgman-Stockbarger method. For the Tl{sub 10}Hg{sub 3}Cl{sub 16} crystal, we have measured X-ray photoelectron spectra for both pristine and Ar{sup +} ion-bombarded surfaces and additionally investigated photoinduced piezoelectricity. Our data indicate that the Tl{sub 10}Hg{sub 3}Cl{sub 16} single crystal surface is very sensitive with respect to Ar{sup +} ion-bombardment. In particular, Ar{sup +} ion-bombardment with energy of 3.0 keV over 5 min at an ion current density of 14 μA/cm{sup 2} causes significant changes of the elemental stoichiometry of the Tl{sub 10}Hg{sub 3}Cl{sub 16} surface resulting in an abrupt decrease of the mercury content in the top surface layers of the studied single crystal. As a result of the treatment, the mercury content becomes nil in the top surface layers. In addition, the present XPS measurements allow for concluding about very low hygroscopicity of the Tl{sub 10}Hg{sub 3}Cl{sub 16} single crystal surface. The property is extremely important for the crystal handling in optoelectronic or nano-electronic devices working at ambient conditions. The photoinduced piezoelectricity has been explored for Tl{sub 10}Hg{sub 3}Cl{sub 16} depending on nitrogen (λ=371 nm) laser power density and temperature. - Graphical abstract: As-grown single crystal boule of Tl{sub 10}Hg{sub 3}Cl{sub 16}; dependence of the effective piezoelecric coefficient d{sub 33} versus the photoinducing nitrogen laser power density, I, at different temperatures, T; and packing of the polyhedra of halide atoms around Hg atoms in the Tl{sub 10}Hg{sub 3}Cl{sub 16} structure. - Highlights: • High-quality Tl{sub 10}Hg{sub 3}Cl{sub 16} single crystal has been grown by Bridgman-Stockbarger method. • Electronic structure of Tl{sub 10}Hg{sub 3}Cl{sub 16} is studied by the XPS method. • Tl{sub 10}Hg{sub 3}Cl{sub 16} single crystal surface is sensitive with respect to Ar{sup +} ion

  14. Comparative study of 201Tl reinjection tomography and combined use of 13N-ammonia and 18F-fluorodeoxyglucose positron emission tomography for detection of viable myocardium

    International Nuclear Information System (INIS)

    Wang Lijuan; Qi Guoxian; Hu Jian

    2001-01-01

    Objective: To compare the clinical value of 201 Tl reinjection tomography and combined use of 13 N-ammonia (NH 3 ) regional myocardial perfusion and 18 F-fluorodeoxyglucose (FDG) positron emission tomography transfer function and for the myocardium. Methods: The authors performed exercise 201 Tl SPECT (Tl SPECT) on 20 patients with myocardial infarction and obtained standard 201 Tl exercise-redistribution images. 201 Tl was reinjected immediately after redistribution study, and the images were then acquired as also. The 20 patients also underwent PET imaging with 13 N-NH 3 and 18 F-FDG (NH 3 -FDG PET) within one week of the above study. Vertical and horizontal long axis cuts were divided into nine segments, and uptakes of radioisotope were evaluated into four classes visually (Defect score, DS) (0:normal uptake, 3:severely reduced). Quantitative evaluation was performed on the vertical and horizontal long axis cuts of 201 Tl redistribution, reinjection and FDG PET images using regions of interest. The relative myocardial 201 Tl uptake and 18 F-FDG uptake (% ID) were expressed as the percentage of this reference region accounted for of the maximal counts. Results: In 48 segments identified as viable by the NH 3 -FDG PET images, 45 (93.8%) segments were also identified as viable by the 201 Tl redistribution imaging. Of 24 segments with severe irreversible defects on the 201 Tl redistribution imaging, 87.5% of the segments were concordantly confirmed by 201 Tl reinjection and NH 3 -FDG PET images with 37.5% identified as viable and 50% identified as scar. There was no significant difference in the average % ID, furthermore, regression analysis revealed a high positive correlation in the segmental % ID between 201 Tl reinjection and FDG PET images in the 61 segments with myocardial infarction (r = 0.722). Conclusions: The results show that 201 Tl reinjection tomography is of similar accuracy with NH 3 -FDG PET for detection of viable myocardium and possess important

  15. Štúdium oneskoreného štiepenia po $\\beta$-rozpade v izotopoch $^{178-182}$Tl

    CERN Document Server

    Andel, Boris

    Topic of the thesis is $\\beta$-delayed fission. We describe nuclear fission, more specifically $\\beta$-delayed fission and its importance in the theoretical part of the thesis. We look briefly to four models of fission barriers (FRLDM, Thomas-Fermi, LSD and ETFSI model) and to $\\alpha$- and $\\beta$-decay of the nucleus. In the beginning of the experimental part of the thesis we describe ISOLDE facility at CERN and the detection setup of our experiment. In result part of the thesis, we are comparing models of fission barriers and analyzing data from the experiment IS466 –(2), which was undertook at ISOLDE. Four separate measurements were performed with the direct production of isotopes $^{178}$Tl, $^{180}$Tl, $^{182}$Tl and $^{202}$Fr. We evaluated delayed fission probabilities of produced isotopes $P_{βDF}\\,$($^{178}$Tl) = (2,8 ± 1,1)$\\times$10$^{-3}$, $P_{βDF}\\,$($^{180}$Tl) = (3,9 ± 1,1)$\\times$10$^{-5}$, $P_{βDF}\\,$($^{182}$Tl) < 1,4$\\times$10$^{-8}$ and $P_{βDF}\\,$($^{202}$Fr) = (2,1 ± 0,4)...

  16. TlHgInS 3 : An Indirect-Band-Gap Semiconductor with X-ray Photoconductivity Response

    Energy Technology Data Exchange (ETDEWEB)

    Li, Hao; Malliakas, Christos D.; Han, Fei; Chung, Duck Young; Kanatzidis, Mercouri G.

    2015-08-11

    The quaternary compound TlHgInS3 crystallizes in a new structure type of space group, C2/c, with cell parameters a = 13.916(3) angstrom, b = 3.9132(8) angstrom, c = 21.403(4) angstrom, beta = 104.16(3)degrees, V = 1130.1(8) angstrom(3), and rho = 7.241 g/cm(3). The structure is a unique three-dimensional framework with parallel tunnels, which is formed by (1)(infinity)[InS33-] infinite chains bridged by linearly coordinated Hg2+ ions. TlHgInS3 is a semiconductor with a band gap of 1.74 eV and a resistivity of similar to 4.32 G Omega cm. TlHgInS3 single crystals exhibit photocurrent response when exposed to Ag X-rays. The mobility-lifetime product (mu tau) of the electrons and holes estimated from the photocurrent measurements are (mu tau)(e) approximate to 3.6 x 10(-4) cm(2)/V and (mu tau)(h) approximate to 2.0 x 10(-4) cm(2)/V. Electronic structure calculations at the density functional theory level indicate an indirect band gap and a relatively small effective mass for both electrons and holes. Based on the photoconductivity data, TlHgInS3 is a potential material for radiation detection applications.

  17. TL and OSL studies on undoped diamond films grown by hot filament chemical vapor deposition

    Energy Technology Data Exchange (ETDEWEB)

    Soni, Anuj, E-mail: anujsoni.phy@gmail.com [Radiological Physics and Advisory Division, Bhabha Atomic Research Center, Mumbai 400 085 (India); Choudhary, R.K. [Materials Processing Division, Bhabha Atomic Research Center, Mumbai 400 085 (India); Polymeris, G.S. [Ankara University, Institute of Nuclear Sciences (Turkey); Mishra, D.R. [Radiological Physics and Advisory Division, Bhabha Atomic Research Center, Mumbai 400 085 (India); Mishra, P. [Materials Processing Division, Bhabha Atomic Research Center, Mumbai 400 085 (India); Kulkarni, M.S. [Radiation Safety Systems Division, Bhabha Atomic Research Center, Mumbai 400 085 (India)

    2016-09-15

    In this work, approximately 0.5 µm thick diamond films were grown on a silicon substrate by hot filament chemical vapour deposition (HFCVD) method in a gas mixture of hydrogen and methane. The batch to batch reproducibility of the sample using this technique was found to be very good. The obtained film was characterized by micro laser Raman spectroscopy (MLRS), grazing incidence X-ray diffractometry (GIXRD), scanning electron microscopy (SEM) and atomic force miscroscopy (AFM) techniques. MLRS and GIXRD results confirmed the formation of diamond whereas SEM and AFM analyses indicated uniform morphology of the film with an average grain size of 200 nm. The deposited film was studied for ionizing radiation dosimetry applications using the thermoluminescence (TL) and optically stimulated luminescence (OSL) techniques after irradiating the film by a calibrated 5 mCi, {sup 90}Sr/{sup 90}Y beta source. In the TL measurement, for a heating rate of 4 K/s, broad glow curve was obtained which was deconvoluted into seven TL peaks. The integrated TL counts were found to vary linearly with increasing the radiation dose up to 10 kGy. The characteristic TL output seen in the temperature range 200–300 °C, may be considered good for thermal stability of the film and it could also avoid TL fading during storage and non-interference of any black body radiation during the measurement. However, in comparison to TL output, the OSL response for 470 nm LED stimulation was found to be lesser. The CW–OSL decay curve has shown two components contributing to the OSL signal, having photoionization cross-section 1.5×10{sup −18} and 5.2×10{sup −19} cm{sup 2} respectively. The studies have revealed the possibility of using diamond film for high dose radiation dosimetry with TL/OSL method.

  18. 201Tl scintigraphic evaluation of tumor mass and viability of bone and soft-tissue tumors

    International Nuclear Information System (INIS)

    Tsuda, Takatoshi; Kubota, Masahiro; Yoshida, Satoru; Shibata, Masahito; Wakabayashi, Jun-ichi; Obata, Hiroyuki; Matsuyama, Toshikatsu; Usui, Masamichi; Ishii, Sei-ichi.

    1994-01-01

    To characterize 201 Tl uptake in patients with bone and soft-tissue tumor, we studied 49 patients with surgically proven tumors and one patient with a tumor diagnosed arteriographically. In 37 of our 50 patients, the tumor was evaluated with 201 Tl and arteriography. Moreover, in 14 of patients with pre-operative chemotherapy, pathologic changes were graded on the basis of percent tumor necrosis as defined histologically. The percent tumor necrosis histologically was compared with changes in the scintigraphic and conventional angiographic studies. Radiologic comparisons demonstrated a high degree of correlation with images of 201 Tl and both arterial and blood pool phase of 99m Tc-HMDP. Ninety-six percent of 28 malignant tumors had positive 201 Tl uptake. None of the patients showed any thallium accumulation in the soft tissues or skeleton adjacent to the lesion. Activity of 201 Tl was mainly dependent upon a tumor blood flow and a vascular density. In of 14 cases with the preoperative chemotherapeutic treatment, 201 Tl scintigraphic changes showed concordance with % tumor necrosis. Thallium-201 was superior to 99m Tc-HMDP in predicting tumor response to chemotherapy. Interestingly, delayed images of 99m Tc-HMDP of 5 responders with >90% tumor necrosis showed decreased uptake in the adjacent bone to the tumor mass lesions. It seems to be quite all right to consider that a major determinant of 201 Tl uptake is intratumoral angiogenecity, which is closely connected with tumor viability. Therefore, 201 Tl is a sensitive radiopharmaceutical for detection of vascular rich bone and soft-tissue tumors, and appears to be a simple and an accurate test for evaluating the response to specific therapeutic regimens of malignant bone and soft-tissue tumors. (author)

  19. A new method for crosstalk correction in simultaneous dual-isotope myocardial imaging with Tl-201 and I-123

    International Nuclear Information System (INIS)

    Tsuji, Akinori; Kojima, Akihiro; Oyama, Yoichi; Tomiguchi, Seiji; Kira, Tomohiro; Takagi, Yoshikazu; Shimomura, Osamu; Takahashi, Mutsumasa; Matsumoto, Masanori

    1999-01-01

    We have developed a new method of crosstalk correction in simultaneous dual-isotope imaging with Tl-201 and I-123 by using crosstalk ratios and a blurring filter. Single isotope myocardial studies (10 for Tl-201 and 7 for I-123) were performed with a dual energy window acquisition mode and two low energy general-purpose collimators. Then two planar images acquired with dual energy windows for a Tl-201 line source and an I-123 line source were obtained to measure line spread functions (LSFs) and crosstalk ratios for each image. The line source experiments showed that the LSFs for the Tl-201 imaging window from the single Tl-201 source were very similar to those for the I-123 imaging window from the single Tl-201 source, but the LSFs for the Tl-201 imaging window from the single I-123 source had broad shapes which differed from those for the I-123 imaging window from the single I-123. To obtain accurate I-123 crosstalk images in the Tl-201 imaging window from the I-123 images in the I-123 imaging window, we designed a low-pass blurring filter. In 7 clinical I-123 MIBG studies, I-123 window images processed with this filter became very similar to the Tl-201 window image from the single I-123 source. The method proposed in this study can accurately correct the crosstalk in dual isotope studies with Tl-201 and I-123 and is easily applicable to conventional gamma camera systems with any dual energy window acquisition mode. (author)

  20. Time of gamma radiation transport in NaI(Tl) scintillators

    International Nuclear Information System (INIS)

    Matarrita, A.S.

    1976-01-01

    The distribution of time intervals in function of the energy, ocurred between the incidence of a gamma radiation in the face of a scintillation crystal and the arrival of the correspondent scintillation at photocathode, is calculated. The mean square fluctuation these time interval, relating to resolution of the detector system is determined. The calculations are done for NaI (Tl) cylindrical crystals with the radiation source placed in the symmetry axis, in two situations: para axial incidence and oblique incidence, indicating a good agreement with experimental data. (M.C.K.) [pt

  1. Mismatched regional myocardial uptake between [sup 123]I-BMIPP and [sup 201]Tl SPECT; Comparison between hypertrophic myocardium and dilated myocardium

    Energy Technology Data Exchange (ETDEWEB)

    Otsuka, Makoto; Ichiya, Yuichi; Kuwabara, Yasuo; Sasaki, Masayuki; Fukumura, Toshimitsu; Masuda, Kouji; Ejima, Junichi; Tsuda, Yasuo (Kyushu Univ., Fukuoka (Japan). Faculty of Medicine)

    1992-07-01

    The distribution of a new myocardial fatty acid metabolic agent [sup 123]I-BMIPP was compared in 6 each patients with hypertrophic myocardium (4 cases of hypertensive heart disease and 2 of hypertrophic cardiomyopathy) and dilated myocardium (4 of dilated type of valvular heart disease and 2 of dilated cardiomyopathy) with that of [sup 201]Tl. Mismatched regional myocardial uptake between [sup 123]I-BMIPP and [sup 201]Tl SPECT was observed in all of the hypertrophic myocardium, however no but one in the dilated myocardium. Relative increase or decrease in regional BMIPP from the images of 20 min and to those of 4 h was observed in 3 cases of the hypertrophic myocardium. FDG-PET was performed in 2 cases of the hypertrophic myocardium. The distribution of FDG was different from neither those of BMIPP nor Tl in a hypertrophic cardiomyopathy case with the reserved distribution of BMIPP and Tl. Although more investigations are necessary, we concluded that [sup 123]I-BMIPP is a promising radiopharmaceutical for evaluating myocardial fatty acid metabolism in hypertrophic myocardium. (author).

  2. MCNP-X Monte Carlo Code Application for Mass Attenuation Coefficients of Concrete at Different Energies by Modeling 3 × 3 Inch NaI(Tl Detector and Comparison with XCOM and Monte Carlo Data

    Directory of Open Access Journals (Sweden)

    Huseyin Ozan Tekin

    2016-01-01

    Full Text Available Gamma-ray measurements in various research fields require efficient detectors. One of these research fields is mass attenuation coefficients of different materials. Apart from experimental studies, the Monte Carlo (MC method has become one of the most popular tools in detector studies. An NaI(Tl detector has been modeled, and, for a validation study of the modeled NaI(Tl detector, the absolute efficiency of 3 × 3 inch cylindrical NaI(Tl detector has been calculated by using the general purpose Monte Carlo code MCNP-X (version 2.4.0 and compared with previous studies in literature in the range of 661–2620 keV. In the present work, the applicability of MCNP-X Monte Carlo code for mass attenuation of concrete sample material as building material at photon energies 59.5 keV, 80 keV, 356 keV, 661.6 keV, 1173.2 keV, and 1332.5 keV has been tested by using validated NaI(Tl detector. The mass attenuation coefficients of concrete sample have been calculated. The calculated results agreed well with experimental and some other theoretical results. The results specify that this process can be followed to determine the data on the attenuation of gamma-rays with other required energies in other materials or in new complex materials. It can be concluded that data from Monte Carlo is a strong tool not only for efficiency studies but also for mass attenuation coefficients calculations.

  3. New Tl{sub 2}LaBr{sub 5}: Ce{sup 3+} crystal scintillator for γ-rays detection

    Energy Technology Data Exchange (ETDEWEB)

    Kim, H.J., E-mail: hongjoo@knu.ac.kr [Department of Physics, Kyungpook National University, Daegu 41566 (Korea, Republic of); Rooh, Gul [Department of Physics, Abdul Wali Khan University, Mardan 23200 (Pakistan); Khan, Arshad [Department of Physics, Kyungpook National University, Daegu 41566 (Korea, Republic of); Kim, Sunghwan [Department of Radiological Science, Cheongju University, Cheongju 41566 (Korea, Republic of)

    2017-03-21

    In this study we present our preliminary report on the scintillation properties of new Ce-doped Tl{sub 2}LaBr{sub 5} single crystal. Two zones vertical Bridgman technique is used for the growth of this compound. Pure and Ce-doped samples showed maximum emission peaks at 435 nm and 415 nm, respectively. Best light yield of 43,000±4300 ph/MeV with 6.3% (FWHM) energy resolution is obtained for 5% Ce-doped sample under γ-ray excitation. Single exponential decay time constant of 25 ns is observed for 5% Ce doped sample. Effective Z-number is found to be 67, therefore efficient detection of X- and γ-ray will be possible. Preliminary results revealed that this compound will be an ideal candidate for the medical imaging techniques. Further investigations are under way for the determination of optimized conditions of this compound. - Highlights: • Scintillation characterization of Tl{sub 2}LaBr{sub 5}: Ce{sup 3+} crystals are presented. • This material is grown by two zone vertical Bridgman technique. • It has high Z{sub eff} therefore, detection efficiency of γ-rays will be higher. • Energy resolution of 6.3% and light yield of 43,000±4300 ph/MeV are obtained. • Single exponential decay of 25 ns is observed under γ-ray excitation.

  4. Myocardial 201Tl washout after combined dipyridamole submaximal exercise stress: Reference values from different patient groups

    International Nuclear Information System (INIS)

    Fridrich, L.

    1989-01-01

    Dipyridamole stress is favorable in patients unable to exercise maximally for 201 Tl myocardial scintigraphy. Aside from an analysis of uptake defects, proper washout analysis can be limited by heart rate variations when isolated dipyridamole stress is used. Heart rate standardized 201 Tl washout kinetics after a combined dipyridamole and submaximal exercise stress protocol (CDSE), feasible in elderly patients as well as in patients with peripheral artery disease, were therefore studied to investigate the 201 Tl washout after CDSE in differently defined patient groups: Group I comprised 19 patients with documented heart disease and angiographically excluded coronary artery disease (CAD); group II contained 17 patients with a very low likelihood of CAD determined by both normal exercise radionuclide ventriculography and normal 201 Tl uptake. Group III comprised 56 patients with a 50% pretest likelihood of CAD but normal 201 Tl uptake. Mean washout values were nearly identical in all groups. Despite similar uptake patterns, however, washout standardized by CDSE was significantly lower than the normal washout values after maximal treadmill exercise. Thus an obviously lower 201 Tl washout after CDSE than after maximal treadmill exercise must be considered if washout analysis criteria after dipyridamole are applied to evaluate ischemic heart disease. Nevertheless, heart rate elevation achieved by additional submaximal exercise stress seems necessary, adequate and clinically safe for standardisation of washout analysis in dipyridamole 201 Tl scintigraphy. (orig.)

  5. Experimental study on the CsI (Tl) crystal anti-compton detector in CDEX

    International Nuclear Information System (INIS)

    Liu Shukui; Yue Qian; Tang Changjian

    2012-01-01

    CDEX (China Dark matter Experiment) Collaboration will carry out direct search for dark matter with Ultra-Low Energy Threshold High Purity germanium (ULE-HPGe) detector at CJPL (China Jinping deep underground Laboratory). Before underground research, some experiments of the CsI (Tl) crystal Anti-Compton detector have been done on the ground, including light guide choice, wrapping material choice, height uniformity of CsI (Tl) crystal, side uniformity of CsI (Tl) crystal and the test results of all the crystals. Through the preliminary work on the ground, we have got some knowledge of the anti-compton detector and prepared for the underground experiment. (authors)

  6. Magnetic measurements on Tl-2212 and Bi-2212 single crystals: a comparative study

    International Nuclear Information System (INIS)

    Oussena, M.; Porter, S.; Volkozub, A.; De Groot, P.A.J.; Lanchester, P.C.; Ogborne, D.; Weller, M.T.; Balakrishnan, G.; Paul, D.McK.

    1994-01-01

    We have compared the magnetic behaviour of two identically shaped single crystals, Tl 2 Ba 2 CaCu 2 O 8 and Bi 2 Sr 2 CaCu 2 O 8 . The critical current density is found to decrease more rapidly with temperature in Bi-2212 although it is the highest in this material at low temperatures (T < 10K). I-V characteristic curves have been obtained from measurements of magnetic sweep rate dependencies of the hysteresis loops. We have found that the characteristic temperature at which flux motion becomes important is significantly higher in Tl-2212 than in Bi-2212. Hence the Tl-2212 has a larger effective pinning. (orig.)

  7. Scintillation detector composed by new type of avalanche photodiode and CsI(Tl) crystal

    International Nuclear Information System (INIS)

    He Jingtang; Chen Duanbao; Li Zuhao; Mao Yufang; Dong Xiaoli

    1996-01-01

    Using S5345 type of avalanche photodiode produced by Hamamatsu for the CsI(Tl) crystal readout, the spectrum of γ ray were measured. Energy resolution of 6.8% for 1.27 MeV γ ray from 22 Na source was obtained. The relation between energy resolution and coupling area, dimension of crystal, shaping time and bias were measured

  8. Reactivity and stability of thallium oxide for fabricating TlSnZnO toward thin-film transistors with high mobility

    Energy Technology Data Exchange (ETDEWEB)

    Kishimoto, Katsushi [Graduate School of Materials Science, Nara Institute of Science and Technology, Nara, 630-0192 (Japan); Nose, Yoshitaro [Department of Materials Science and Engineering, Kyoto University, Kyoto, 606-8501 (Japan); Ishikawa, Yasuaki, E-mail: yishikawa@ms.naist.jp [Graduate School of Materials Science, Nara Institute of Science and Technology, Nara, 630-0192 (Japan); Fujii, Mami N.; Uraoka, Yukiharu [Graduate School of Materials Science, Nara Institute of Science and Technology, Nara, 630-0192 (Japan)

    2016-07-05

    Thermal reaction between thallium oxide (Tl{sub 2}O{sub 3}) and zinc oxide (ZnO), tin oxide (SnO{sub 2}) or indium oxide (In{sub 2}O{sub 3}) annealed at 600 °C for 18 h in the air atmosphere was investigated. From XRD results of 600 °C annealed samples, Tl{sub 2}O{sub 3} had the biggest reactivity compared with ZnO. The EDX results suggest the mechanism in which the thallium atoms scattered and attached uniformly only on ZnO particles. We also analyzed XPS data to compare O 1s bond and Tl 4f bond of as-mixed samples with that of annealed samples, and found that Zn and Sn can contribute in improving Tl and O bonding stability. However, the affinity of In for Tl is weaker than that of Zn or Sn. Finally, we prepared the samples mixed with ZnO, SnO{sub 2}, and Tl{sub 2}O{sub 3} powder and the samples mixed with Zn{sub 2}SnO{sub 4} and Tl{sub 2}O{sub 3} powder annealed at 600 °C for 18 h. Results show that Zn{sub 2}SnO{sub 4} has the same or more reactivity than SnO{sub 2} and ZnO mixed particle despite of the more stable and sufficient dispersion of Zn and Sn atoms. More stable TlSnZnO can be fabricated from Zn{sub 2}SnO{sub 4} + Tl{sub 2}O{sub 3} powder by suitable thermal processes. It is expected that TlSnZnO sputtering target can be fabricated by suitable calcination. - Highlights: • Thermal reaction of Tl{sub 2}O{sub 3} and ZnO, SnO or In{sub 2}O{sub 3} were investigate. • It is found that Tl{sub 2}O{sub 3} is reactive with ZnO rather than SnO or In{sub 2}O{sub 3}. • Two-step annealing process is promising route for forming TlSnZnO tablet.

  9. Discordant Tl-201 and Tc-99m imaging in a patient with thyroid carcinoma and Hashimoto's disease

    International Nuclear Information System (INIS)

    Morita, S.; Ishibashi, M.; Hirayama, T.; Kumabe, T.; Ohtake, H.

    1990-01-01

    In a case of Hashimoto's disease complicated by thyroid gland cancer, the primary site of the cancer was visualized as a cold nodule on Tc-99m pertechnetate scintigraphy, as a warm nodule on Tl-201 early imaging, and as a hot nodule on Tl-201 delayed imaging. Generally, Tl-201 shows markedly diffuse accumulation in the lesions of Hashimoto's disease. The warm nodules observed on early scans suggested similar accumulation at the sites of Hashimoto's disease and thyroid cancer. The hot nodules on delayed imaging may be due to the difference in Tl-201 washout time between the sites of Hashimoto's disease and thyroid cancer. There was markedly increased Tl-201 accumulation in bilateral cervical metastatic lymph nodes on both early and delayed images

  10. Non-radiation induced signals in TL dosimetry

    International Nuclear Information System (INIS)

    German, U.; Weinstein, M.

    2002-01-01

    One source of background signals, which are non-radiation related, is the reader system and it includes dark current, external contaminants and electronic spikes. These factors can induce signals equivalent to several hundredths of mSv. Mostly, the effects are minimised by proper design of the TLD reader, but some effects are dependent on proper operation of the system. The other main group of background signals originate in the TL crystal and is due to tribothermoluminescence, dirt, chemical reactions and stimulation by visible or UV light. These factors can have a significant contribution, equivalent to over several mSv, depending on whether the crystal is bare or protected by PTFE. Working in clean environments, monitoring continuously the glow curve and performing glow curve deconvolution are suggested to minimise non-radiation induced spurious signals. (author)

  11. Core breaking and octupole low-spin states in $^{207}$ Tl

    CERN Multimedia

    We propose to study the low-spin level structure of the $^{207}$Tl nucleus populated by the $\\beta$- decay of $^{207}$Hg. While $^{207}$Tl is a single-proton hole nucleus, the majority of the observed states will have a three-particle structure thus requiring the breaking of the neutron or proton core, or a collective octupole phonon coupled to the single proton hole. Thus information will be obtained on the single particle orbitals in the vicinity of the N=126 and Z=82 magic numbers, and on the size of the shell gap. The results will be used to improve the predictive power of the shell model for more exotic nuclei as we move to lighter N=126 nuclei.The experiment will use the ISOLDE Decay station, and will take advantage of the $^{207}$Hg beam from the molten lead target. A test on the feasibility to produce an $^{208}$Hg beam from the same target, with the aim to study the $\\beta$-decay into $^{208}$Tl, could be performed at the same time.

  12. A Ge(Li)-NaI(Tl) Compton-suppression spectrometer for in-beam γ-ray spectroscopy, ch. 2

    International Nuclear Information System (INIS)

    Driel, M.A. van; Hoogenboom, A.M.

    1976-01-01

    A Compton-suppression spectrometer has been constructed for in-beam γ-ray work. It consists of a closed-end Ge(Li) detector with an efficiency of 21% and a resolution of 2.0 keV for 1.33 MeV γ-rays surrounded by a NaI(Tl) shield (dia. 230 mm, length 280 mm). The overall Compton-suppression factor for a 60 Co spectrum is 10. Details of the construction are discussed and experimental properties are compared with design calculations

  13. Ultraviolet radiation dosimetry using CaF2 TL phosphors- state of the art

    International Nuclear Information System (INIS)

    Nagpal, J.S.

    2001-01-01

    Photoluminescence (PL), optical absorption (OA) and thermoluminescence (TL) of undoped and Dy, Tb- and Eu activated CaF 2 TL phosphors has been re-investigated after heat treatment (600-1100 degC) in air. The study confirmed the earlier observed increase in intrinsic UV response of CaF 2 : Dy 3+ after 900 degC heat treatment. Enhancement in UV response was also observed in undoped CaF 2 thus indicating the base matrix related phenomenon. However, the enhancement observed in UV sensitivity and the optimum treatment temperature for high UV sensitivity is different for different activators. It is activator specific and needs further probing. UV response of undoped CaF 2 monotonically increases as the treatment temperature (in air) is increased from 600 degC to 1100 degC. Similar increase is observed in case of CaF 2 : Tb 3+ also. However, CaF 2 : Dy 3+ and CaF 2 :Eu 2+ follow a different pattern. Heat treatment in air increases UV response of CaF 2 : Dy 3+ up to 900 degC, and a decrease is observed at higher temperatures. UV response of CaF 2 : Eu 2+ is maximum for 600 degC treatment in air and decreases thereafter. TL response of CaF 2 : Tb and CaF 2 : Eu 2+ phosphors to UV is high, can be employed over the range 10 -2 - 2 mJ.cm -2 and is rate independent for 250±10 nm UV. (author)

  14. {sup 201}Tl scintigraphy in the evaluation of palpable and nonpalpable breast lesions: correlation with mammography and ultrasonography

    Energy Technology Data Exchange (ETDEWEB)

    Vural, G.; Atasever, T.; Oezdemir, A.; Oeznur, I.; Karabacak, N.I.; Goekcora, N.; Isik, S. [Gazi Univ., Dept. of Nuclear Medicine, Ankara (Turkey)]|[Gazi Univ., Dept. of Radiology, Ankara (Turkey); Uenlue, M. [Gazi Univ., Dept. of Nuclear Medicine, Ankara (Turkey)

    1997-12-01

    Tl-201 scintigraphy were performed in sixty-eight patients with 70 breast abnormalities (51 palpable, 19 nonpalpable) and compared with mammography and ultrasonography (US). Early (15 min) and late (3 h) images of the breasts were obtained following the injection of 111 MBq (3 mCi) of Tl-201. Visual and semiquantitative interpretation was performed. Final diagnosis confirmed 52 malignant breast lesions and 18 benign conditions. Tl-201 visualized 47 of 52 (90%) overall malignant lesions. Thirty-eight of 40 (95%) palpable and 9 of 12 (75%) nonpalpable breast cancers were detected by Tl-201 scintigraphy. The smallest mass lesion detected by Tl-201 measured 1.5x1.0 cm. Eleven breast lesions were interpreted as indeterminate by mammography and/or sonography. Tl-201 scintigraphy excluded malignancy in 7 of 8 (88%) patients with benign breast lesions interpreted as indeterminate. Five of the 18 (28%) benign breast lesions showed Tl-201 uptake. None of the fibroadenoma and fibrocystic changes accumulated Tl-201. Tl-201 scintigraphy, mammography and ultrasonography showed 90%, 92%, 85% overall sensitivity and 72%, 56%, 61% overall specificity respectively. Twenty-one of the 28 (75%) axillary nodal metastatic sites were also detected by Tl-201. In malignant and benign lesions, early and late lesion/contralateral normal side (L/N) ratios were 1.58{+-}0.38 (mean{+-}SD) and 1.48{+-}0.32 (p>0.05), 1.87{+-}0.65 and 1.34{+-}0.20 (p<0.5) respectively. The mean early and late L/N ratios of malignant and benign groups did not show statistical difference (p>0.05). (orig./MG) [Deutsch] 68 Patientinnen mit insgesamt 70 Laesionen (davon 51 palpable Tumoren) wurden untersucht: 15 Min. und 3 Std. nach Injektion von 111 MBq (3 mCi) {sup 201}Tl-Cl wurden planare Aufnahmen von ventral, lateral und schraeg-lateral durchgefuehrt. Die Auswertung erfolgte sowohl visuel-qualitativ als auch semiquantitativ. Von 52 Karzinomen wurden durch die {sup 201}Tl-Szintigraphie 47 (90%) richtig erkannt

  15. Improvements in the Tl dosimetry for Radiotherapy

    International Nuclear Information System (INIS)

    Bustos, S.; Velez, G.; Rubio, M.

    1998-01-01

    The thermoluminescent dosimetry (TLD) in vivo has been demonstrated to be one of the most reliable for the control of radiotherapeutic treatments, but the delay in the response is the main disadvantage in its applicability. In this work are presented important improvements and it is demonstrated that maintaining the accuracy and reliability of the technique, it is possible to accelerate the response times at a few hours. To realize this work is utilized a lecturer Harshaw 4000, dosemeters LiF-TLD-100 chips (3.1 x 3.1 x 0.89 mm 3 ) and rods (1 x 1 x 6 mm 3 ). With the implementation of a glow curve analysis program developed in CIEMAT, its obtained a Tl peaks separation in such manner rapid and accurate, by that the thermal treatment of dosemeters may be reduced at one unique annealing pre-irradiation for 1 hr at 400 Centigrade. It is realized a periodical and individual calibration of the TLD and a study of the factors which influencing the ratio Tl signal-dose as linearity, correction by energy, directional response and pride of Tl signal. the results of this study are introducing in a calculation list specially designed and which allows to obtain absorbed dose by TLD starting of the dates (dosimetric peaks area) which appear of the glow curves analysis. The dose is obtained with an accuracy less than 5 %. The dosemeters already irradiated (in vivo) are analysed and informed in only four hours, allowing a greater control of the treatment and a correction of the possible errors for the next session, still in bi fractional treatments. The method implemented results thus accurate, rapid and reliable. (Author)

  16. Trace element geochemistry and thermoluminescence (TL) of quartz ...

    African Journals Online (AJOL)

    *

    3Department of Materials Science and Engineering, Tsinghua University, Beijing 100084, China. ... exposure in the recent twenty years, the TL characteristics of the fish otolith have not yet been ..... New discoveries in the study of carp otoliths.

  17. Experimental studies on using silicon photodiode as read-out component of CsI(Tl) crystal

    International Nuclear Information System (INIS)

    He Jingtang; Chen Duanbao; Li Zuhao; Mao Yufang; Dong Xiaoli

    1996-01-01

    Experimental studies on using silicon photodiode as the read-out component of CsI(Tl) crystal are reported. The read-out properties of two different types of silicon photodiode produced by Hamamatsu were measured, including relations between energy resolution and bias, shaping time, sensitive area of photodiode and the dimension of the crystal

  18. Development of low-background CsI(Tl) crystals for WIMP search

    International Nuclear Information System (INIS)

    Lee, H.S.; Bhang, H.; Hahn, I.S.; Hwang, M.J.; Kim, H.J.; Kim, S.C.; Kim, S.K.; Kim, S.Y.; Kim, T.Y.; Kim, Y.D.; Kwak, J.W.; Kwon, Y.J.; Lee, J.; Lee, J.I.; Lee, M.J.; Li, J.; Myung, S.S.; Park, H.; Zhu, J.J.

    2007-01-01

    Search for weakly interacting massive particles (WIMPs) is being carried out at the underground laboratory, Yangyang, Korea. Characteristics and internal background of CsI(Tl) crystal have been investigated. In our extensive R and D, we reduced internal background in the CsI(Tl) crystal. With the latest, we have achieved 5.50+/-0.10cpd (counts/keV/kg/day) at 10-15keV low-energy region. Further reduction of internal background is foreseen with the CsI powder lately produced

  19. Serial assessment of left ventricular function in various patient groups with Tl-201 gated myocardial perfusion SPECT

    International Nuclear Information System (INIS)

    Wei Lingge; Kadoya, Masumi; Momose, Mitsuhiro; Kurozumi, Masahiro; Matsushita, Tsuyoshi; Yamada, Akira

    2007-01-01

    The present study was performed to assess stress-related left ventricular (LV) function variations in various patient groups and to determine if they were affected by sex or the type of stress experienced. We used thallium (Tl)-201 gated myocardial perfusion single-photon emission computed tomography (SPECT) for the analysis. A total of 270 patients were examined by electrocardiography-gated myocardial perfusion SPECT imaging to assess LV function. After injection of Tl-201 at a dose of 111 MBq at peak stress, SPECT scans were acquired at 10 min (after stress) and 3 h (rest) after injection on a three-headed camera. In the normal perfusion group, the mean LV ejection fraction (LVEF) was significantly higher, and both the end-diastolic volume index (EDVI) and end-systolic volume index (ESVI) were significantly lower in women than in men (P<0.05). Poststress stunning occurred in 29 of 98 patients (30.0%) in the ischemia group and in 42 of 90 patients (46.7%) in the fixed group. There was a significant difference in poststress stunning between bicycle ergometer stress and dipyridamole stress (P<0.05). In patients with normal perfusion, LVEF, EDVI, and ESVI determined by gated Tl-201 SPECT should be corrected for sex. In addition, the influence of the type of stress should be considered when assessing stress-related LV function variations. (author)

  20. Performance of Linear and Nonlinear Two-Leaf Light Use Efficiency Models at Different Temporal Scales

    DEFF Research Database (Denmark)

    Wu, Xiaocui; Ju, Weimin; Zhou, Yanlian

    2015-01-01

    The reliable simulation of gross primary productivity (GPP) at various spatial and temporal scales is of significance to quantifying the net exchange of carbon between terrestrial ecosystems and the atmosphere. This study aimed to verify the ability of a nonlinear two-leaf model (TL-LUEn), a linear...... two-leaf model (TL-LUE), and a big-leaf light use efficiency model (MOD17) to simulate GPP at half-hourly, daily and 8-day scales using GPP derived from 58 eddy-covariance flux sites in Asia, Europe and North America as benchmarks. Model evaluation showed that the overall performance of TL...

  1. Dipole response of the odd-proton nucleus 205Tl up to the neutron-separation energy

    Science.gov (United States)

    Benouaret, N.; Beller, J.; Pai, H.; Pietralla, N.; Ponomarev, V. Yu; Romig, C.; Schnorrenberger, L.; Zweidinger, M.; Scheck, M.; Isaak, J.; Savran, D.; Sonnabend, K.; Raut, R.; Rusev, G.; Tonchev, A. P.; Tornow, W.; Weller, H. R.; Kelley, J. H.

    2016-11-01

    The low-lying electromagnetic dipole strength of the odd-proton nuclide 205Tl has been investigated up to the neutron separation energy exploiting the method of nuclear resonance fluorescence. In total, 61 levels of 205Tl have been identified. The measured strength distribution of 205Tl is discussed and compared to those of even-even and even-odd mass nuclei in the same mass region as well as to calculations that have been performed within the quasi-particle phonon model.

  2. Dipole response of the odd-proton nucleus 205Tl up to the neutron-separation energy

    International Nuclear Information System (INIS)

    Benouaret, N; Beller, J; Pai, H; Pietralla, N; Ponomarev, V Yu; Romig, C; Schnorrenberger, L; Zweidinger, M; Scheck, M; Isaak, J; Savran, D; Sonnabend, K; Raut, R; Rusev, G; Tonchev, A P; Tornow, W; Weller, H R; Kelley, J H

    2016-01-01

    The low-lying electromagnetic dipole strength of the odd-proton nuclide 205 Tl has been investigated up to the neutron separation energy exploiting the method of nuclear resonance fluorescence. In total, 61 levels of 205 Tl have been identified. The measured strength distribution of 205 Tl is discussed and compared to those of even–even and even–odd mass nuclei in the same mass region as well as to calculations that have been performed within the quasi-particle phonon model. (paper)

  3. Tl{sub 2}LaCl{sub 5} (Ce{sup 3+}): New fast and efficient scintillator for X- and γ-ray detection

    Energy Technology Data Exchange (ETDEWEB)

    Kim, H.J., E-mail: hongjoo@knu.ac.kr [Department of Physics, Kyungpook National University, Daegu 41566 (Korea, Republic of); Rooh, Gul [Department of Physics, Abdul Wali Khan University, Mardan 23200 (Pakistan); Kim, Sunghwan [Department of Radiological Science, Cheongju University, Cheongju 41566 (Korea, Republic of)

    2017-06-15

    Scintillation properties of the new Tl{sub 2}LaCl{sub 5}: xCe{sup 3+} where x=0, 0.5, 1 and 10 mol % (TLC: Ce{sup 3+}) single crystals are presented. Two zones vertical Bridgman technique is used for the growth of this scintillation material. High Z-number (79) of this material offer excellent detection efficiency for X- and γ-rays. Grown samples are characterized under X- and γ-rays excitation in order to find the emission wavelength, energy resolution, light yield, and decay time. Emission spectra exhibit Ce{sup 3+} emission bands between 350–550 nm and peaking at 389 nm. The obtained energy resolution and light yield increases with high Ce-concentration. Energy resolution and light yield of 10%Ce-doped sample are found to be 6.9% (FWHM) and 51,000±5000 ph/MeV, respectively at room temperature. For the grown samples, two exponential decay time constants are found. The measured decay time constants showed variation in their values with respect to Ce-concentrations in the host crystal. Fast decay time constant of 31 ns with 87% light emission is found for 10%Ce sample. Scintillation results suggested that TLC will be one of the promising next generation scintillator for the medical imaging techniques such as Positron Emission Tomography (PET).

  4. Magnetic measurements on Tl-2212 and Bi-2212 single crystals: a comparative study

    Energy Technology Data Exchange (ETDEWEB)

    Oussena, M. (Physics Dept., Univ. of Southampton (United Kingdom)); Porter, S. (Physics Dept., Univ. of Southampton (United Kingdom)); Volkozub, A. (Physics Dept., Univ. of Southampton (United Kingdom)); De Groot, P.A.J. (Physics Dept., Univ. of Southampton (United Kingdom)); Lanchester, P.C. (Physics Dept., Univ. of Southampton (United Kingdom)); Ogborne, D. (Physics Dept., Univ. of Southampton (United Kingdom) Chemistry Dept., Univ. of Southampton (United Kingdom)); Weller, M.T. (Physics Dept., Univ. of Southampton (United Kingdom) Chemistry Dept., Univ. of Southampton (United Kingdom)); Balakrishnan, G. (Physics Dept., Univ. of Southampton (United Kingdom) Physics Dept., Univ. of Warwick, Coventry (United Kingdom)); Paul, D.McK. (Physics Dept., Univ. of Southampton (United Kingdom) Physics Dept., Univ. of Warwick, Coventry (United Kingdom))

    1994-02-01

    We have compared the magnetic behaviour of two identically shaped single crystals, Tl[sub 2]Ba[sub 2]CaCu[sub 2]O[sub 8] and Bi[sub 2]Sr[sub 2]CaCu[sub 2]O[sub 8]. The critical current density is found to decrease more rapidly with temperature in Bi-2212 although it is the highest in this material at low temperatures (T < 10K). I-V characteristic curves have been obtained from measurements of magnetic sweep rate dependencies of the hysteresis loops. We have found that the characteristic temperature at which flux motion becomes important is significantly higher in Tl-2212 than in Bi-2212. Hence the Tl-2212 has a larger effective pinning. (orig.)

  5. Hydrogen/deuterium exchange mass spectrometry and computational modeling reveal a discontinuous epitope of an antibody/TL1A Interaction.

    Science.gov (United States)

    Huang, Richard Y-C; Krystek, Stanley R; Felix, Nathan; Graziano, Robert F; Srinivasan, Mohan; Pashine, Achal; Chen, Guodong

    2018-01-01

    TL1A, a tumor necrosis factor-like cytokine, is a ligand for the death domain receptor DR3. TL1A, upon binding to DR3, can stimulate lymphocytes and trigger secretion of proinflammatory cytokines. Therefore, blockade of TL1A/DR3 interaction may be a potential therapeutic strategy for autoimmune and inflammatory diseases. Recently, the anti-TL1A monoclonal antibody 1 (mAb1) with a strong potency in blocking the TL1A/DR3 interaction was identified. Here, we report on the use of hydrogen/deuterium exchange mass spectrometry (HDX-MS) to obtain molecular-level details of mAb1's binding epitope on TL1A. HDX coupled with electron-transfer dissociation MS provided residue-level epitope information. The HDX dataset, in combination with solvent accessible surface area (SASA) analysis and computational modeling, revealed a discontinuous epitope within the predicted interaction interface of TL1A and DR3. The epitope regions span a distance within the approximate size of the variable domains of mAb1's heavy and light chains, indicating it uses a unique mechanism of action to block the TL1A/DR3 interaction.

  6. Identification of irradiated spices by the use of thermoluminescence method (TL)

    Energy Technology Data Exchange (ETDEWEB)

    Sharifzadeh, M.; Sohrabpour, M. (Atomic Energy Organization of Iran, Teheran (Iran, Islamic Republic of))

    In this paper the results of the investigation of identification of irradiated spices by the use of thermoluminescence method is reported. The materials used were black and red peppers, turmeric, cinnamon, and garlic powder. Gamma Cell 220 was used for irradiating samples at dose values of 2.5, 5, 7.5 and 10 kGy respectively. The TL intensity of the unirradiated spices as well as the fading characteristics of the irradiated samples having received a dose of 10 kGy have been measured. Post-irradiation temperature treatment of the irradiated (10 kGy) and unirradiated samples at 60[sup o]C and 100[sup o]C for 24 hours have also been performed. The results show that the TL intensities of unirradiated and irradiated samples from different batches of each spice are fairly distributed. A reasonable TL intensity versus dose has been observed in nearly all cases. Based on the observation made it is possible to distinguish irradiated spices after (4-9) months post-irradiation. (author).

  7. Identification of irradiated spices by the use of thermoluminescence method (TL)

    International Nuclear Information System (INIS)

    Sharifzadeh, M.; Sohrabpour, M.

    1993-01-01

    In this paper the results of the investigation of identification of irradiated spices by the use of thermoluminescence method is reported. The materials used were black and red peppers, turmeric, cinnamon, and garlic powder. Gamma Cell 220 was used for irradiating samples at dose values of 2.5, 5, 7.5 and 10 kGy respectively. The TL intensity of the unirradiated spices as well as the fading characteristics of the irradiated samples having received a dose of 10 kGy have been measured. Post-irradiation temperature treatment of the irradiated (10 kGy) and unirradiated samples at 60 o C and 100 o C for 24 hours have also been performed. The results show that the TL intensities of unirradiated and irradiated samples from different batches of each spice are fairly distributed. A reasonable TL intensity versus dose has been observed in nearly all cases. Based on the observation made it is possible to distinguish irradiated spices after (4-9) months post-irradiation. (author)

  8. X-ray photoemission analysis of chemically modified TlBr surfaces for improved radiation detectors

    International Nuclear Information System (INIS)

    Nelson, A. J.; Voss, L. F.; Beck, P. R.; Graff, R. T.; Conway, A. M.; Nikolic, R. J.; Payne, S. A.; Lee, J.-S.; Kim, H.; Cirignano, L.; Shah, K.

    2013-01-01

    We subjected device-grade TlBr to various chemical treatments used in room temperature radiation detector fabrication to determine the resulting surface composition and electronic structure. As-polished TlBr was treated separately with HCl, SOCl 2 , Br:MeOH and HF solutions. High-resolution photoemission measurements on the valence band electronic structure and Tl 4f, Br 3d, Cl 2p and S 2p core lines were used to evaluate surface chemistry and shallow heterojunction formation. Surface chemistry and valence band electronic structure were correlated with the goal of optimizing the long-term stability and radiation response

  9. Myocardial scintigraphy with 199Tl chloride for the assessment of antianginal effect of cardil

    International Nuclear Information System (INIS)

    Chernov, V.I.; Mordovin, V.F.; Vesnina, Zh.V.; Triss, S.V.; Bazilevich, I.A.; Lishmanov, Yu.B.

    1995-01-01

    The aim of this research was examination of myocardial perfusion in cardil therapy of twenty-two coronary patients and analysis of potentialities of load 199 Tl scintigraphy in assessment of the antianginal effect in the course of therapy of coronary patients. The findings evidence that due to short 199 Tl half life and low radiation load of the body because of this radionuclide load 199 Tl scintigraphy of the myocardium carried out in the course of therapy of coronary patients may be used as an objective test to assess myocardial perfusion under the effect of treatment. 8 refs

  10. Investigation and dating of gypsum crystals from Sivrihisar region in Eskisehir by ESR and TL techniques

    International Nuclear Information System (INIS)

    2011-01-01

    Gypsum crystals taken from Sivrihisar-Eskisehir district were investigated and dated by Electron Spin Resonance (ESR) and Thermoluminescence (TL) techniques. The natural ESR spectra of gypsum samples had also the signals of Mn 2 + in addition to the signal at g=2.009. It was observed that the intensity of ESR signal at g=2.009 increased with gamma irradiation dose. This ESR signal (g=2.009) was used as a dating signal in dating of gypsum samples. The only one TL peak at about 278 degree Celsius was observed in TL glow curves of nonirradiated gypsum sample. In the case of irradiated sample, TL peak at 157 degree Celsius was observed in addition of TL peak at 278 degree Celsius. Gypsum samples were irradiated with a 6 0Co gamma source. The ESR spectra and TL glow curve of gypsum samples were recorded by X-band ESR spectrometer and Risφ TL/OSL reader, respectively. For samples, ESR/TL dose-response curves was constructed. Dose-response curves were fitted with an exponential saturation function. Based on this model, accumulated dose (AD) values for dating are determined. 2 38U, 2 32Th and 4 0K analysis was carried out for gypsum crystals and dolomite which enveloped these gypsum crystals. The internal dose rate was calculated from 2 38U, 2 32Th and 4 0K analysis results of gypsum sample. The external dose rate was calculated by using 2 38U, 2 32Th and 4 0K analysis results of dolomite and cosmic dose rate. Internal and external gamma dose-rate was used for dating calculations. Because of successive recrystallization of gypsum sample after formation, calculated age values of gypsum is smaller than expected formation age.

  11. Difference in 201TlCl accumulation mechanism in brain tumors. A comparison of their Na+-K+ ATPase activities

    International Nuclear Information System (INIS)

    Sugo, Nobuo; Kuroki, Takao; Nemoto, Masaaki; Mito, Toshiaki; Seiki, Yoshikatsu; Shibata, Iekado

    2000-01-01

    The accumulation levels of 201 TlCl and Na + -K + ATPase activity in tumor tissue were compared among glioblastoma, benign glioma and meningioma to study the difference in the mechanism of 201 TlCl accumulation. The subjects were 19 cases comprised of 6 glioblastoma, 2 oligodendroglioma, 1 fibrillary astrocytoma, 1 pilocytic astrocytoma and 9 meningioma. Preoperative 201 TlCl SPECT was performed in all the cases, and Thallium Index (TL index) was calculated by a ratio of 201 TlCl in the tumor area and the contralateral area. In addition, cell membrane was extracted from the tumor tissue collected intraoperatively to determine Na + -K + ATPase activity. No statistically significant difference in TL index was noted between the glioblastoma group (6.97±2.67) and the meningioma group (5.87±1.99). This fact showed that there was no difference in the accumulation level of 201 TlCl between the two groups. On the other hand, the glioblastoma group indicated a higher value of Na + -K + ATPase activity (49.13±43.76 μmole/hour/mg protein) than the meningioma group (7.73±13.84 μmol/hour/mg protein) (p + -K + ATPase activity in 201 TlCl accumulation in glioblastoma and the influences of other accumulation mechanism than Na + -K + ATPase activity such as the volume of intratumoral vascular bed in meningioma. (author)

  12. TL sensitivity constancy of quartz upon UV+(β,γ) irradiation cycle: An improvement on dating methodology

    International Nuclear Information System (INIS)

    Souza, J.H.

    1985-01-01

    Thermoluminescence (TL) sensivitivy of natural quartz (beaches, paleobeaches and fixed dunes) to Beta and Gamma rays has been studied in a temperature range between 250-400 0 C, before and after bleaching by solar irradiation. A first TL glow growth curve was obtained through Beta irradiation of 'as found' samples and a second glow growth curve was obtained by bleaching through solar irradiation the TL acquired either through an excitation Gamma dose or through environmental radiation to finally re-irradiate the samples under Beta rays. Experimental results showing the constancy of sensitivity, for doses of until about 10K rads, are the basis for a proposal to improve TL dating methodology expanding its present limits. (Author) [pt

  13. Stark broadening parameters and transition probabilities of persistent lines of Tl II

    Science.gov (United States)

    de Andrés-García, I.; Colón, C.; Fernández-Martínez, F.

    2018-05-01

    The presence of singly ionized thallium in the stellar atmosphere of the chemically peculiar star χ Lupi was reported by Leckrone et al. in 1999 by analysis of its stellar spectrum obtained with the Goddard High Resolution Spectrograph (GHRS) on board the Hubble Space Telescope. Atomic data about the spectral line of 1307.50 Å and about the hyperfine components of the spectral lines of 1321.71 Å and 1908.64 Å were taken from different sources and used to analyse the isotopic abundance of thallium II in the star χ Lupi. From their results the authors concluded that the photosphere of the star presents an anomalous isotopic composition of Tl II. A study of the atomic parameters of Tl II and of the broadening by the Stark effect of its spectral lines (and therefore of the possible overlaps of these lines) can help to clarify the conclusions about the spectral abundance of Tl II in different stars. In this paper we present calculated values of the atomic transition probabilities and Stark broadening parameters for 49 spectral lines of Tl II obtained by using the Cowan code including core polarization effects and the Griem semiempirical approach. Theoretical values of radiative lifetimes for 11 levels (eight with experimental values in the bibliography) are calculated and compared with the experimental values in order to test the quality of our results. Theoretical trends of the Stark width and shift parameters versus the temperature for spectral lines of astrophysical interest are displayed. Trends of our calculated Stark width for the isoelectronic sequence Tl II-Pb III-Bi IV are also displayed.

  14. 灵芝新品种‘泰山赤灵芝1号(TL-1)’%A New Ganoderma lucidum Cultivar‘Taishan Chilingzhi 1(TL-1)’

    Institute of Scientific and Technical Information of China (English)

    兰玉菲; 安秀荣; 王庆武; 王明才; 于清伟; 唐丽娜; 李秀梅

    2011-01-01

    ‘泰山赤灵芝1号(TL-1)’是由泰山野生种驯化选育而成。菌丝最适生长温度25~28℃,子实体生长最适温度25~30℃;代料栽培发菌需要45 d左右,从原基形成到子实体采收需要55 d左右。子实体菌盖半圆形或近肾形,红褐色至土褐色,具有光泽,干品转化率达14%以上。具有产量高,出芝整齐等特点。%The new Ganoderma lucidum cultiva‘r Taishan Chilingzhi 1(TL-1)’was derived from wild species collected from Mountain Tai.The optimum growth temperature of mycelia is 25–28 ℃,and the optimum temperature for fructification stage is 25–30 ℃.It takes about 45 days for mycelium full run when using bag culture.It usually takes 55 days from primordial formation to harvest.The pileus is semi-circle,mahogany to muddy colour and glossy.The biological efficiency of dry goods is above 14%.It has high yield and the fruiting body appearance tidiness.

  15. Reader's Response: What Is a SoTL?

    Science.gov (United States)

    Griebenow, Kai

    2010-01-01

    In this response to, "SoTL Commons Conference: A Spirit of Inquiry" (Margaret Davis, Kera Watkins, and Deborah Allen, "International Journal for the Scholarship of Teaching and Learning,"v3 n2 Jul 2009), Griebenow adds his personal impressions as an "SOTL newbie." He states that many scientists have an idea of…

  16. Quantitative evaluation of right ventricular overload in cor pulmonale using sup 201 Tl myocardial SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Kato, Hiroshi; Misawa, Toshihiro; Kutsumi, Yasunori [Fukui Medical School, Matsuoka (Japan); and others

    1991-01-01

    To determine quantitatively the discriminant and characteristics of cor pulmonale, {sup 201}Tl myocardial perfusion SPECT was performed in 16 patients with chronic obstructive pulmonary disease (COPD) and 7 with restrictive pulmonary disease (RPD). One section of the short-axis SPECT image in which the right ventricle was most clearly visualized was selected. Tl-score was defined as the ratio of the sum of counts in the region of interest (ROI) at the anterior, mid, and posterior regions of the right ventricular free wall to the sum of counts in ROI at the posterior, lateral, and anterior walls of the left ventricle, and the anterior and posterior regions of the interventricular septum. In the group of COPD patients, Tl-score was positively correlated with mean pulmonary arterial pressure (mPAP), total pulmonary vascular resistance (TPR), and arterial carbon dioxide tension (PaCO{sub 2}), while it was inversely correlated with arterial oxygen tension (PaO{sub 2}). However, there was no significant correlation between Tl-score and mPAP, TPR, PaCO{sub 2}, and PaO{sub 2} in the group of RPD patients. In assessing pulmonary hypertension as defined by mPAP over 20 mmHg, a Tl-score greater than 0.25 was useful with a sensitivity of 69% and a specificity of 90%. The occurrence of cor pulmonale is a major factor in determining the prognosis of COPD patients. It was concluded that {sup 201}Tl myocardial SPECT is useful for evaluating right ventricular overload quantitatively, as well as for assessing core pulmonale, especially in COPD patients, since the ratio of Tl counts in the right and left ventricles was significantly correlated with right cardiopulmonary hemodynamic parameters. (N.K.).

  17. OSL and TL retrospective dosimetry with a fluorapatite glass-ceramic used for dental restorations

    International Nuclear Information System (INIS)

    Ekendahl, Daniela; Judas, Libor; Sukupova, Lucie

    2013-01-01

    Optically Stimulated Luminescence (OSL) and Thermoluminescence (TL) properties of a fluorapatite glass-ceramic have been investigated, with a view to developing a dose assessment technique for medical triage following unplanned exposures of individuals to ionizing radiation. The ceramic is an innovative material used in dental prostheses and restorations. It is strongly sensitive to radiation and the intensity of both the OSL and TL signals are proportional to the absorbed radiation dose. We focused on the optimization of the measuring procedure and investigated characteristics such as reproducibility, fading, minimum detectable dose (MDD), dose response and photon energy response of TL and OSL signals. The dental ceramic exhibited very good reproducibility (<5% at 2σ level) when measured and a linear dose response for a wide range of doses (50 mGy–20 Gy). The MDD values for the samples investigated were ∼5 mGy. The material is not tissue equivalent and the OSL and TL signals are strongly dependent on incident photon energy. Both the luminescence signals exhibited significant fading during the first few hours after irradiation. Its rate was dependent on the parameters of measurement. The results indicate that the material can be used for the purposes of accident dosimetry, however, the fading and photon energy response have to be properly corrected for a reliable dose assessment. - Highlights: ► A dental ceramic was considered as a retrospective and accident dosimeter. ► Dosimetry application was investigated using OSL and TL. ► TL and OSL signals are proportional to absorbed radiation dose. ► Accuracy is dependent on correction of fading and photon energy response

  18. Understanding NaI(Tl) crystal background for dark matter searches

    Energy Technology Data Exchange (ETDEWEB)

    Adhikari, G.; Adhikari, P.; Kong, S.Y.; Oh, S.Y. [Sejong University, Department of Physics and Astronomy, Seoul (Korea, Republic of); Ha, C.; Jeon, E.J.; Kim, N.Y.; Lee, H.S.; Park, J.S.; Park, K.S. [Institute for Basic Science (IBS), Center for Underground Physics, Daejeon (Korea, Republic of); Kim, Y.D. [Institute for Basic Science (IBS), Center for Underground Physics, Daejeon (Korea, Republic of); Sejong University, Department of Physics and Astronomy, Seoul (Korea, Republic of)

    2017-07-15

    We have developed ultra-low-background NaI(Tl) crystals to reproduce the DAMA results with the ultimate goal of achieving purity levels that are comparable to or better than those of the DAMA/LIBRA crystals. Even though the achieved background level does not approach that of DAMA/LIBRA, it is crucial to have a quantitative understanding of the backgrounds. We have studied background simulations toward a deeper understanding of the backgrounds and developed background models for a 9.16-kg NaI(Tl) crystal used in the test arrangement. In this paper we describe the contributions of background sources quantitatively by performing Geant4 Monte Carlo simulations that are fitted to the measured data to quantify the unknown fractions of the background compositions. In the fitted results, the overall simulated background spectrum well describes the measured data with a 9.16-kg NaI(Tl) crystal and shows that the background sources are dominated by surface {sup 210}Pb and internal {sup 40}K in the 2-6-keV energy interval, which produce 2.4 counts/day/keV/kg (dru) and 0.5 dru, respectively. (orig.)

  19. Comparison of 201Tl solution sources in UK hospitals, 2001

    International Nuclear Information System (INIS)

    Baker, M.; Woods, M.

    2001-01-01

    During recent years, concerns have been raised within the nuclear medicine field about the accuracy of activity measurements for 201 Tl. And indeed, NPL calibrations repeatedly indicated that the level of impurities present in such samples and the significant amount of activity adsorbed onto the glass wall of the container could produce erroneous results. In addition, the standard P6 vials, in which 201 Tl solution had been previously supplied, were recently replaced with the new ''10R Type 1 plus'' Schott vials. To assess the magnitude of these effects on the accuracy of clinical measurements of the activity of 201 Tl, an intercomparison exercise was conducted between the National Physical Laboratory (NPL), Nycomed-Amersham (NA) and the UK hospital physics community. The majority of the 273 reported results were within the ± 10 % limit of accuracy that hospitals aim to achieve for diagnosis, biased high. The tendency to overestimate the activity was more evident for syringe measurements. The exercise also revealed that the adsorption losses experienced with P6 vials had been solved by the introduction of the 10R vials, but individual calibrators need to be recalibrated for this new container. (author)

  20. Clinical use of 201Tl myocardial scintigraphy

    International Nuclear Information System (INIS)

    Senda, Kohei; Imaeda, Takeyoshi; Kato, Toshimitsu; Asada, Shuichi; Doi, Hidetaka

    1977-01-01

    Myocardial imaging with 201 Tl and scinticamera was studied experimentally using specially designed phantoms and clinically in 23 patients with myocardial infarction or other heart disease. In the phantom experiment, quality of image, accumulative count rate, and detectability of the defect were compared to obtain the best technique for their detection, using four different collimators, i.e., converging, pin-hole, 4000-hole, and 140 keV high-resolution, at two photopeak levels of 201 Tl of 75 and 167 keV, and combining a radiation absorber. In patient examination, myocardial images taken at different periods after injection, different detecting conditions of the scinticamera, and various detecting projections were compared. Images of the converging collimator at the 75 keV photopeak revealed considerably higher accumulative counts and relatively higher quality than those of other detecting conditions. It was necessary to take as many images as possible in various projections, in order to detect the location and size of the myocardial ischemic lesion because the lesion was demonstrated as a clear defect only in profile. It became evident that images taken between about 25 and 90 min delineated the myocardium more clearly than those taken in other periods. Normal images taken in 8 patients without ischemic heart disease appeared in the shape of a doughnut of horseshoe, demonstrating mainly the left venticular myocardium. The image was faint in the region of the aortic or mitral valve and thin in the region of the apical wall. A faint image of the right ventricular myocardium was sometimes seen. In 3 patients with valvular heart disease, findings suggested changes in the thickness of myocardium and the distribution of coronary blood flow. In 11 of 12 patients with old myocardial infarction, the location and size of the lesion was detected. (Evans, J.)

  1. TL dating of pottery sherds and baked soil from the Xian Terracotta Army Site, Shaanxi Province, China

    International Nuclear Information System (INIS)

    Lu Yanchou; Zhang Jingzhao; Xie Jun

    1988-01-01

    Six ceramics and two baked soil samples collected from the famous Xian Terracotta Army Site have been dated by using fine grain (2-8 μ) thermoluminescence (TL) technique. Five samples of pottery sherds exhibited peak TL at about 275 0 C and 395 0 C gave the TL age ranges from 2.13 ± 0.14 ka to 2.25 ± 0.14 ka and a mean TL age of 2.20 ± 0.15 ka, with a good plateau in the range of 290-400 0 C. Another sample, however, showed a larger peak at 365 0 C and could not be dated because of serious fading. TL ages of 1.93 ± 0.13 ka and 2.20 ± 0.19 ka have been also obtained from the baked soil samples with a plateau between 300 and 350 0 C. The TL dates of the ceramics and baked soil are consistent with C-14 dates on charcoal samples taken from the same layer in Xian Terracotta Army Site. It is consistent with other evidence that the Terracotta Army figures were made about 2200 yr ago and that the site burned down soon afterwards. (author)

  2. Pulse shape analysis using CsI(Tl) Crystals

    International Nuclear Information System (INIS)

    Silva, J.; Fiori, E.; Loher, B.; Savran, D.; Wirth, R.; Vencelj, M.

    2013-06-01

    The decay time of CsI(Tl) scintillating material consists of more than a single exponential component. The ratio between the intensity of these components varies as a function of the ionizing power of the absorbed particles, such as γ -rays or protons, and the temperature. This property can therefore be used for particle discrimination and for temperature monitoring, using pulse shape analysis. An unsupervised method that uses fuzzy clustering algorithms for particle identification based on pulse shape analysis is presented. The method is applied to discriminate between photon and proton-induced signals in CsI(Tl) scintillator detectors. The first results of a method that uses pulse shape analysis for correcting the temperature-dependent gain effect of the detector are also presented. The method aims at conserving a good energy resolution in a temperature varying environment without the need to measure the temperature of the detector externally (authors)

  3. CsI(Tl)-photodiode detectors for gamma-ray spectroscopy

    CERN Document Server

    Fioretto, E; Viesti, G; Cinausero, M; Zuin, L; Fabris, D; Lunardon, M; Nebbia, G; Prete, G

    2000-01-01

    We report on the performances of CsI(Tl)-photodiode detectors for gamma-ray spectroscopy applications. Light output yield and energy resolution have been measured for different crystals and read-out configurations.

  4. Estimation of infarct size by myocardial emission computed tomography with 201Tl and its relation to creatine kinase-MB release after myocardial infarction in man

    International Nuclear Information System (INIS)

    Tamaki, S.; Nakajima, H.; Murakami, T.

    1982-01-01

    We evaluated emission computed tomography (ECT) 201 Tl myocardial imaging in estimating infarct size (IS). In 18 patients in whom IS was estimated enzymatically at the time of the acute episode, planar 201 Tl perfusion scintigraphy and ECT with a rotating gamma camera were performed 4 weeks after the first myocardial infarction. From the size of 201 Tl perfusion defects, the infarct area in planar images and the infarct volume in reconstructed ECT images were measured by computerized planimetry. When scintigraphic IS was compared with the accumulated creatine kinase-MB isoenzyme release (CK-MBr), infarct volume determined from ECT correlated closely with CK-MBr (r . 0.89), whereas infarct area measured from planar images correlated less satisfactorily with the enzymatic IS (for an average infarct area from three views, r . 0.69; for the largest infarct area, r . 0.73). Although conventional scintigraphic evaluation is useful for detecting and localizing infarction, quantification of ischemic injury with this two-dimensional technique has a significant inherent limitation. The ECT approach can provide a more accurate three-dimensional quantitative estimate of infarction, and can corroborate the enzymatic estimate of IS

  5. Anomalous fading of the TL, Blue-SL and IR-SL signals of fluorapatite

    International Nuclear Information System (INIS)

    Tsirliganis, N.; Polymeris, G.; Loukou, Z.; Kitis, G.

    2006-01-01

    The thermoluminescence (TL), blue stimulated luminescence (BSL) and infrared stimulated luminescence (IRSL) signals of fluorapatite (originating from Durango, Mexico) were measured and found to exhibit strong anomalous fading (AF). The experimentally obtained OSL and IRSL decay curves were transformed into pseudo-linear modulated (pseudo-LM) decay curves. The resulting glow-curve shaped pseudo-LM decay curves were analyzed using a deconvolution analysis, similar to the one used for the glow-curve deconvolution (GCD) of TL glow-curves. It was found that the pseudo-LM OSL and IRSL decay curves consist of two components named fast and slow, respectively, and their individual contribution was estimated. The AF of the remnant TL, BSL and IRSL as a function of the storage time was fitted using the tunneling model equations and the fading rate g, in terms of percentage per decade was evaluated. According to the obtained g values, the AF of the BSL and IRSL is stronger than that of the TL. The AF of the fast component of BSL and IRSL is almost the same. The AF of the slow component of IRSL is, by approximately a factor of 2, stronger than that of the BSL

  6. Effects of cross talk on dual energy SPECT imaging between [sup 123]I-BMIPP and [sup 201]Tl

    Energy Technology Data Exchange (ETDEWEB)

    Morita, Masato; Narita, Hitoshi; Yamamoto, Juro; Fukutake, Naoshige; Ohyanagi, Mitsumasa; Iwasaki, Tadaaki; Fukuchi, Minoru (Hyogo College of Medicine, Nishinomiya (Japan))

    1994-01-01

    The study was undertaken to determine how much cross talk influences the visual assessment of dual energy single photon emission computed tomographic (SPECT) images with iodine 123 beta-methyl-p-iodophenylpentadecanoic acid (I-123 BMIPP) and thallium-201 in 15 patients with acute myocardial infarction. After single SPECT with I-123 BMIPP was undertaken, simultaneous dual SPECT with I-123 BMIPP and Tl-201 were undertaken in all patients. Three patients also underwent single SPECT with Tl-201. I-123 BMIPP and Tl-201 uptake was graded in four-score for the comparison between single and dual SPECT images. There was good correlation between dual energy SPECT and both single I-123 BMIPP SPECT (pS=0.97) and single Tl-201 SPECT (pS=0.59). Uptake scores were increased on dual energy SPECT, compared with single I-123 SPECT (8 out of 132 segments) and single Tl-201 SPECT (12 out of 36 segments). Overall, there was a comparatively well correlation between single SEPCT with either I-123 BMIPP or Tl-201 and dual energy SPECT images. However, one tracer uptake sometimes increased in the other tracer defect areas. This was noticeable when I-123 BMIPP exerted an effect on Tl-201. (N.K.).

  7. The comparison of nitroglycerin interventional dual-isotope myocardium perfusion imaging and 201Tl re-injection imaging to detect viable myocardium

    International Nuclear Information System (INIS)

    Gao Zhou; Shi yu; Chen Hongyan; Jia Shaowei

    2002-01-01

    Objective: Employing the differences in physical properties of 99m Tc-MIBI and 201 Tl, the authors discuss the contrast result of nitroglycerin interventional dual-isotope myocardium perfusion imaging and 201 Tl re-injection imaging to detect viable myocardium so that authors can enhance the image quality and shorten the examination time. Method: 34 OMI patients took the 99m Tc-MIBI and 201 Tl dual-isotope myocardium perfusion imaging and 201 Tl re-injection imaging respectively in two weeks. During the peak of normal dipyridamole stress i.v. 201 Tl 100 MBq was given and myocardium imaging was taken 15 min later. The dual-isotope group was given nitroglycerin 1mg under the tongue. Five min later, i.v. 99m Tc-MIBI 1110 mBq was given. In 201 Tl re-injection group i.v. 201 Tl 40 MBq was given 4 hour later and were imaged. Among the 34 OMI patients, 19 patients undertook another 99m Tc-MIBI static imaging. Results: There are no obvious differences between nitroglycerin interventional dual-isotope myocardium perfusion imaging and 201 Tl re-injection imaging in detection rate of viable myocardium, χ 2 =0.823, p>0.25. But they have great difference in perfusion changed sectional myocardium absorb rate, t=2.73, p 2 =27.867, p 201 Tl re-injection imaging

  8. Evaluation of brain tumors by simultaneous dual isotope SPECT with 201Tl-chloride and 99mTc-MIBI

    International Nuclear Information System (INIS)

    Nagai, Hidemasa; Yamasaki, Toshiki; Yamamoto, Yoshiaki; Takada, Daikei; Miyazaki, Takeshi; Sugimoto, Keiji; Matsumoto, Yoshifumi; Akiyama, Yasuhiko; Moritake, Kouzo

    2004-01-01

    Single photon emission computed tomography (SPECT) is useful for detecting brain tumors. In this study, we evaluated the utility of simultaneous dual SPECT with 201 Tl-Chloride (Tl) and 99m Tc-MIBI (MIBI) for diagnosis of brain tumors. We evaluated 20 cases, including 2 glioblastomas, 7 anaplastic astrocytomas, 2 oligodendrogliomas, 2 anaplastic ependymomas, 2 medulloblastomas, 2 meningiomas, 1 malignant meningioma, 1 pituitary adenoma, and 1 craniopharyngioma. We analyzed the uptake ratio (T/N ratio) of tracers in both Tl and MIBI at max counts/pixels ratio in the region of interest. The T/N ratios in early and delayed images were described as early ratios (ER) and delay ratios (DR), respectively. The retention index (RI) was calculated as the DR/ER ratio. Significant correlations were found between ER and DR for both Tl (DR=0.797 x ER+0.359, r=0.871), and MIBI (DR=0.961 x ER-0.191, r=0.784). Next, we analyzed the correlations between Tl and MIBI SPECT, for ER, DR, and RI. ER values for the two were strongly correlated (r=0.791), DR values were weakly correlated (r=0.556), and RI exhibited no correlation between them (r=0.328). There were no correlations between tumor volume and T/N ratio for the two (ER-Tl; r=0.0095, DR-Tl; r=0.0050, ER-MIBI; r=0.036, DR-MIBI; r=0.254). Lastly no correlation was found between RI-Tl and RI-MIBI (r=0.328). We discuss the difference in the mechanism of accumulation of two tracers and the significance of simultaneous dual SPECT using them for the differential diagnosis of pituitary tumors, regrowth of oligodendrogliomas, and multi-drug resistance of chemotherapy. Dual SPECT with Tl and MIBI appears to be useful for the diagnosis of brain tumor. (author)

  9. Direct and indirect signal detection of 122 keV photons with a novel detector combining a pnCCD and a CsI(Tl) scintillator

    Energy Technology Data Exchange (ETDEWEB)

    Schlosser, D.M., E-mail: dieter.schlosser@pnsensor.de [PNSensor GmbH, Sckellstraße 3, 81667 München (Germany); Huth, M.; Hartmann, R. [PNSensor GmbH, Sckellstraße 3, 81667 München (Germany); Abboud, A.; Send, S. [Universität Siegen, Walter-Flex-Straße 3, 57072 Siegen (Germany); Conka-Nurdan, T. [Türkisch-Deutsche Universität, Sakinkaya Cad. 86, Beykoz, 34820 Istanbul (Turkey); Shokr, M.; Pietsch, U. [Universität Siegen, Walter-Flex-Straße 3, 57072 Siegen (Germany); Strüder, L. [PNSensor GmbH, Sckellstraße 3, 81667 München (Germany); Universität Siegen, Walter-Flex-Straße 3, 57072 Siegen (Germany)

    2016-01-01

    By combining a low noise fully depleted pnCCD detector with a CsI(Tl) scintillator, an energy-dispersive area detector can be realized with a high quantum efficiency (QE) in the range from below 1 keV to above 100 keV. In direct detection mode the pnCCD exhibits a relative energy resolution of 1% at 122 keV and spatial resolution of less than 75 µm, the pixel size of the pnCCD. In the indirect detection mode, i.e. conversion of the incoming X-rays in the scintillator, the measured energy resolution was about 9–13% at 122 keV, depending on the depth of interaction in the scintillator, while the position resolution, extracted with the help of simulations, was 30 µm only. We show simulated data for incident photons of 122 keV and compare the various interaction processes and relevant physical parameters to experimental results obtained with a radioactive {sup 57}Co source. - Highlights: • Position and energy resolving pnCCD+CsI(Tl) detector for energies from 1-150 keV • Detection in the pnCCD (122keV): 1% energy and <75µm spatial resolution • Detection in the scintillator (122keV): 9-12% energy and ~30µm spatial resolution.

  10. Cation composition and oxygen content dependence of crystal structure and T sub c for Tl sub 2 sub - sub x Ba sub 2 Ca sub 2 Cu sub 3 sub + sub z O sub y

    CERN Document Server

    Idemoto, Y; Koura, N; Kamiyama, T; Oikawa, K; Izumi, F

    2003-01-01

    Tl sub 2 sub - sub x Ba sub 2 Ca sub 2 Cu sub 3 sub + sub z O sub y (Tl-2223 system) superconducting oxides with various Tl contents and Cu contents were prepared. We investigated the relation between crystal structure and superconducting property dependence of Tl and Cu content. First, we obtained an almost single-phase material at a Tl content 2-x = 1.7 and the Tl-2223 phase remained the main phase in the region of 2 - x >= 0.631 of Tl sub 2 sub - sub x Ba sub 2 Ca sub 2 Cu sub 3 O sub y. T sub c was about 120 K for the Tl-2223 in a wide range of 0.631 <= 2 - x <= 1.761. Second, we obtained a single-phase at 2 - x = 1.777 and Cu content 3 + z = 3.284 of Tl sub 2 sub - sub x Ba sub 2 Ca sub 2 Cu sub 3 sub + sub z O sub y. The T sub c (zero) dependence of Cu/Tl ratio, showed a maximum value of 122 K at Cu/Tl ratio = 2.026. Based on results of crystal structure refinements by powder neutron diffraction, it was found that the change in bond length and angle dependence of average Cu valence were similar fo...

  11. Assessment of left ventricular function by 201Tl FCG-gated myocardial SPECT

    International Nuclear Information System (INIS)

    Toba, Masahiro; Ishida, Yoshio; Fukuchi, Kazuki; Fukushima, Kazuhito; Katafuchi, Tetsurou; Hayashida, Kohei; Oka, Hisashi; Takamiya, Makoto

    1999-01-01

    We applied the QGS program for LV function analysis (described by Germano, 1995) to a 201 Tl SPECT study at rest, and estimated its accuracy. We performed 201 Tl ECG-gated myocardial SPECT in 25 patients with ischemic heart disease under an acquisition time used in the routine 99m Tc ECG-gated SPECT study. The quality of the gated images was visually assessed with a 4-point grading system. LVEDV, LVESV, LVEF determined by the QGS program were compared with those by Simpson's method on biplane LVG in 25 patients. Regional wall motion scores in 7 myocardial segments were assessed on the three-dimensional display created by the QGS program and the cine display of biplane LVG with a 5-point grading system. Wall motion scores obtained by the QGS program were compared with those by LVG. Although 72.0% of 201 Tl ECG-gated SPECT images were fair or poor in image quality, there were good correlations between the values obtained by the QGS program and LVG (LVEDV: r=0.82, LVESV: r=0.88, LVEF: r=0.89). In addition, wall motion scores by the QGS program were correspondent to those by LVG in 77.1% of all 175 myocardial segments. We conclude that the QGS program provides high accuracy in evaluating left ventricular function even from 201 Tl ECG-gated myocardial SPECT data. (author)

  12. Removal of 99mTc and 201Tl by means of Lemna Gibba

    International Nuclear Information System (INIS)

    Fernandez R, E.; Carreno de L, M. C.; Cuevas S, J. C.; Hernadez T, U. O.; Monroy G, F.

    2012-10-01

    In this work the capacity of the water macrophyte Lemna gibba coming from San Pedro Tultepec in the Mexico State was studied to remove the radioisotopes 99m Tc and 201 Tl, in order to show the capacity of this macrophyte for to treat some radioactive waste flowing that could contain this radioisotopes type. The removal capacity of 99m Tc and 201 Tl of the macrophyte Lemna gibba was determined using the batch method. In accordance with the values of the obtained K d , the Lemna gibba with a size of particle diameter among 1mm - 300 μm presents a better adsorption of 99m Tc. The 201 Tl is adsorbed better in the bioadsorbent when it has a size of particle diameter <150μm. (Author)

  13. Study of method of efficiency transference using detectors NaI(Ti)

    International Nuclear Information System (INIS)

    Ramos, Thiago L.; Salgado, César M.

    2017-01-01

    The use of NaI (Tl) scintillation detectors for measurements implies the determination of the detection efficiency as a function of the energy of the incident photons. The efficiency curve can be obtained experimentally with the use of several mono-energy sources calibrated with emission energies covering the whole range of interest or using the Monte Carlo method. The Institute of Nuclear Engineering develops several methodologies using these detectors as they are robust, inexpensive and do not need cooling for their use. The assembly of an experimental arrangement is usually complex, since several factors influence the result affecting reproducibility in measurements, such as: parallelism between source and detector, alignment between source and detector, and accuracy of source-detector distance. In view of such difficulties, an automated positioning system was developed for the source-detector set controlled by a micro controller based on the ARDUINO language in order to guarantee the reproducibility in the experimental arrangements. In the initial phase of this study, a mathematical model was developed in the MCNP-X code using a NaI (Tl) detector. A theoretical validation using the Efficiency Transfer Method was performed at three different positions on the detector's axial axis (10.6 cm, 11.3 cm and 12.0 cm). This method is based on the ratio of effective solid angles. The experimental validation presented maximum relative errors of 7.74% for the position 11.3 cm

  14. Dual myocardial scintigraphic imaging using 123I-BMIPP and 201Tl in patients with Duchenne's progressive muscular dystrophy

    International Nuclear Information System (INIS)

    Sasaki, Akira

    1996-01-01

    Dual single photon emission computed tomography (SPECT) was performed in 30 patients with Duchenne's muscular dystrophy (DMD) using 201 thallium (Tl) for myocardial perfusion 123 I-β-methyl-p-iodophenylpentadecanoic acid (BMIPP) for myocardial fatty acid metabolism scintigraphy. The left ventricle was divided into 9 regions, and accumulation of the radiotracers was assessed visually for each region to calculate defect score for each tracer. There was some degree of decrease in the myocardial accumulation of both tracers in all DMD patients. Reduced accumulation was most common at the apex (BMIPP, 70%; Tl, 63%), followed by the posterior wall, lateral wall, and anterior wall. It was less common on the apical side of the ventricular septum for both tracers (BMIPP, 3%; Tl, 17%). Accumulation of Tl was lower than BMIPP in 18/30 patients (60%) and higher in 9 (30%), while both tracers showed equal accumulation in 3 (10%). BMIPP showed higher accumulation than Tl in all regions but the septum. A significant negative correlation was found between the defect scores for both tracers and the left ventricular ejection fraction (LVEF) (r=-0.629 for Tl; r=-0.567 for BMIPP). The strongest negative correlation was that between the sum of the Tl and BMIPP defect scores and the LVEF (r=-0.681). Dual SPECT myocardial scintigraphy with Tl and BMIPP provided an accurate evaluation of the progression of cardiac lesions in DMD by detecting abnormalities of the myocardial metabolism of each substance thereby enabling the assessment of left ventricular function. (author)

  15. A new protocol of dual energy acquisition on stress 201Tl and rest 99mTc-tetrofosmin myocardial scintigraphy

    International Nuclear Information System (INIS)

    Maeno, Masakazu; Matsuo, Takeshi; Imamura, Takurou; Koiwaya, Yasushi; Eto, Tanenao; Nagamachi, Shigeki; Jinnouchi, Seishi

    2001-01-01

    We carried out stress 201 Tl (Tl) and rest 99m Tc-tetrofosmin (TF) myocardial scintigraphy with dual energy acquisition in 24 patients with suspected ischemic heart disease performed coronary arteriography and elucidated the sensitivity of this method. One hour after light meal eating, TF (555 MBq) was injected intravenously at rest and after 3 minutes from injection of TF exercise or pharmacologic stress was performed. During stress Tl (111 MBq) was injected intravenously before end-point or at adequate point of pharmacologic stress. Dual energy acquisition using triple energy windows (TEW) was started after 5 minutes (early) and 4 hours (delayed) from stress. The sensitivity (Sn), specificity (Sp) and accuracy (Ac) in diagnosis of non-infarcted branches by using Tl (early)-TF (rest) and Tl (early)-Tl (delayed) were 79% vs. 53% (Sn), 78% vs. 96% (Sp) and 79% vs. 71% (Ac) respectively. Accordance of uptake score of infarcted region between TF (rest) and Tl (delayed) was 70%. In conclusion, this protocol is seemed to be useful as usual protocol for detection of myocardial ischemia and viability during about only 1 hour. (author)

  16. First principle study of structural, electronic and thermodynamic behavior of ternary intermetallic compound: CeMgTl

    Directory of Open Access Journals (Sweden)

    R.P. Singh

    2014-12-01

    Full Text Available To study the structural, electronic and thermodynamic behavior of CeMgTl, full-potential linear augmented plane wave plus local orbital (FP-LAPW + lo method has been used. The lattice parameters (a0, c0, bulk modulus (B0 and its first order pressure derivative (B0′ have been calculated for CeMgTl. Band structure and density of states histograms depicts that “5d” orbital electrons of Tl have dominant character in the electronic contribution to CeMgTl. Impact of the temperature and pressure on unit cell volume, bulk modulus, Debye temperature, Grüneisen parameter, specific heat and thermal expansion coefficient (α have been studied in wide temperature range (0–300 K and pressure range (0–15 GPa.

  17. Dielectric Losses and Charge Transfer in Antimony-Doped TlGaS2 Single Crystal

    Science.gov (United States)

    Asadov, S. M.; Mustafaeva, S. N.

    2018-03-01

    Effect of semimetallic antimony (0.5 mol % Sb) on the dielectric properties and ac-conductivity of TlGaS2-based single crystals grown by the Bridgman-Stockbarger method has been studied. The experimental results on the frequency dispersion of dielectric coefficients and the conductivity of TlGa0.995Sb0.005S2 single crystals allowed the revealing of the dielectric loss nature, the charge transfer mechanism, and the estimation of the parameters of the states localized in the energy gap. The antimony-doping of the TlGaS2 single crystal leads to an increase in the density of states near the Fermi level and a decrease in the average time and average distance of hopes.

  18. Comparison of laboratory and in situ evaluation of environmental TL dosimeters

    International Nuclear Information System (INIS)

    Deme, S.; Apathy, I.; Feher, I.; Osvay, M.

    1996-01-01

    The passive environmental gamma-radiation dosimetry is mainly based on TL (thermoluminescent) dosimetry. This method offers considerable advantages due to its high precision, low cost, wide range, etc.. At the same time its application involves uncertainty caused by the dose collected during the transport from the point of annealing to the place of exposure and back to the place of evaluation. Should an accident occur read-out is delayed due to the need to transport to a laboratory equipped with a TLD reader. A portable reader capable of reading out the TL dosimeter at the place of exposure (in situ TLD reader) eliminates the disadvantages mentioned above. A microprocessor based portable TLD reader was developed by us for monitoring environmental gamma-radiation doses. Using a portable reader for in situ evaluation there are several disadvantages as well. The method requires the transport of the reader instead of dosimeters. The portable reader should be battery operated with low power consumption. Due to this requirement the temperature stabilization of the reader requests different solution as in laboratory type devices. Comparison of recently developed in situ and traditional laboratory evaluation methods of environmental TL dosimeters is given in recent paper. The comparison was made in the same conditions. The most characteristic - for environmental monitoring - numerical TL data (dose range, reproducibility, fading, self dose etc.) are given for manufactured by us CaSO 4 :Dy bulbs (portable reader) and very advantageous, high sensitive Al 2 O 3 :C dosimeters (laboratory evaluation). (author)

  19. Quaternary chalcogenides of the IVa metals with layered structures: preparation and crystal structures of TlCuTIVQ3 (T=Zr, Hf; Q=S, Se) and their relation to the Re3B structure type

    International Nuclear Information System (INIS)

    Klepp, K.O.; Gurtner, D.

    1996-01-01

    The new compounds TlCuT IV Q 3 (T = Zr, Hf; Q = S, Se) were prepared by reacting intimate mixtures of Tl 2 S or TlSe with stoichiometric amounts of the corresponding Group IV metal, Cu and the corresponding chalcogen at 870 . The four compounds are isostructural and crystallize in Cmcm, Z = 4 with a 3.726(4) A, b = 13.987(9) A, c = 9.783(4) A for TlCuZrS 3 ; a = 3.847(1) A, b 14.381(6) A, c = 10.150(1) A for TlCuZrSe 3 ; a = 3.694(1) A, b = 14.030(3) A, c = 9.750(3) A for TlCuHfS 3 ; and a = 3.831(1) A, b = 14.409(9) A, c = 10.124(2) A for TlCuHfSe 3 . Their crystal structures were determined from single crystal diffractometer data (Mo Kα radiation, ambient temperature) and refined to conventional R values of 0.016, 0.040, 0.019 and 0.031 respectively. An outstanding feature of their crystal structures is the formation of infinite anionic layers, 2 ∞ -[CuT IV Q 3 ] - parallel to (010), which are separated by Tl + cations. These layers are built up by edge sharing TQ 6 octahedra and distorted CuQ 4 tetrahedra. Average T-Q distances are anti d(Zr-S) = 2.586(1) A, anti d(Zr-Se) = 2.707(1) A, anti d(Hf-S) = 2.569(2) A and anti d(Hf-Se) = 2.694(1) A. Cu-chalcogen distances are anti d(Cu-S) = 2.318(2) A and anti d(Cu-Se) = 2.432(3) A respectively. The thallium ions are in bicapped trigonal prismatic chalcogen coordinations. The atomic arrangement corresponds to that of KCuZrS 3 ; based on the thallium-chalcogen partial structure it can be regarded as a filled variant of an anti-Re 3 B structure type. (orig.)

  20. Thallium contamination in arable soils and vegetables around a steel plant-A newly-found significant source of Tl pollution in South China.

    Science.gov (United States)

    Liu, Juan; Luo, Xuwen; Wang, Jin; Xiao, Tangfu; Chen, Diyun; Sheng, Guodong; Yin, Meiling; Lippold, Holger; Wang, Chunlin; Chen, Yongheng

    2017-05-01

    Thallium (Tl) is a highly toxic rare element. Severe Tl poisoning can cause neurological brain damage or even death. The present study was designed to investigate contents of Tl and other associated heavy metals in arable soils and twelve common vegetables cultivated around a steel plant in South China, a newly-found initiator of Tl pollution. Potential health risks of these metals to exposed population via consumption of vegetables were examined by calculating hazard quotients (HQ). The soils showed a significant contamination with Tl at a mean concentration of 1.34 mg/kg. The Tl levels in most vegetables (such as leaf lettuce, chard and pak choy) surpassed the maximum permissible level (0.5 mg/kg) according to the environmental quality standards for food in Germany. Vegetables like leaf lettuce, chard, pak choy, romaine lettuce and Indian beans all exhibited bioconcentration factors (BCF) and transfer factors (TF) for Tl higher than 1, indicating a hyperaccumulation of Tl in these plants. Although the elevated Tl levels in the vegetables at present will not immediately pose significant non-carcinogenic health risks to residents, it highlights the necessity of a permanent monitoring of Tl contamination in the steel-making areas. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. Identification of food preserved by ionizing radiation; Preliminary tests in strawberries using thermoluminescent (TL)

    International Nuclear Information System (INIS)

    Rubio, T.; Sillano, O.; Espinoza, J.; Roman, A.; Deza, A.

    1992-01-01

    TL measurements, of irradiated and unirradiated strawberries were carried out, using peel, seeds (achenes), leaves and sediment. The four types of samples presented a different thermoluminescence response. The best results were obtained with sediment removed from the soil of the fruit surface. It is concluded that TL is a promising technique for detecting irradiated strawberries using sediment samples. (author)

  2. $\\beta$-decay study of neutron-rich Tl and Pb isotopes

    CERN Multimedia

    It is proposed to study the structure of neutron-rich nuclei beyond $^{208}$Pb. The one-proton hole $^{211-215}$Tl and the semi magic $^{213}$Pb will be produced and studied via nuclear and atomic spectroscopy searching for long-lived isomers and investigating the $\\beta$-delayed $\\gamma$- emission to build level schemes. Information on the single particle structure in $^{211-215}$Pb, especially the position of the g$_{9/2}$ and i$_{11/2}$ neutron orbitals, will be extracted along with lifetimes. The $\\beta$-decay will be complemented with the higher spin selectivity that can be obtained by resonant laser ionization to single-out the decay properties of long-living isomers in $^{211,213}$Tl and $^{213}$Pb.

  3. Hyper- and hypobaric processing of Tl-Ba-Ca-Cu-O superconductors

    Science.gov (United States)

    Goretta, K. C.; Routbort, J. L.; Shi, Donglu; Chen, J. G.; Hash, M. C.

    1989-11-01

    Tl-based superconductors of initial composition Tl:Ca:Ba:Cu equal to 2:2:2:3 and 1:3:1:3 were heated in oxygen at pressures of 10(sup 4) to 6 (times) 10(sup 5) Pa. The 2:2:2:3 composition formed primarily the 2-layer superconductor with zero resistance from 77 to 104 K. The 1:3:1:3 composition formed nearly phase pure 3-layer superconductor with a maximum zero resistance temperature of 120 K. Application of hyperbaric pressure influenced phase purities and transition temperatures slightly; phase purities decreased significantly with application of hypobaric pressures.

  4. Performance of a high-resolution CsI(Tl)-PIN readout detector

    International Nuclear Information System (INIS)

    Kudenko, Yu.G.; Imazato, J.

    1992-10-01

    A study of a large-volume CsI(Tl) detector with a PIN diode readout was carried out. Our results show a light output of ≤20000 photoelectrons/MeV, an equivalent noise charge (rms) of about 900 electrons, and an equivalent noise level of ≤ 60 keV. We obtained an energy resolution of 11.2% (fwhm) for 1275 keV gamma rays from a 22 Na source. The characteristics of the PIN - preamplifier system as well as the parameters of a small CsI(Tl) - PIN detector with a direct and wavelength shifter readout are also reported. (author)

  5. Stability of Tl(III) in the context of speciation analysis of thallium in plants.

    Science.gov (United States)

    Sadowska, Monika; Biaduń, Ewa; Krasnodębska-Ostręga, Beata

    2016-02-01

    The paper presents both "good" and "bad" results obtained during speciation analysis of thallium in plant tissues of a hyperaccumulator of this metal. The object was white mustard - Sinapis alba L. In this plant there were found traces of trivalent thallium. The crucial point of this study (especially in the case of so unstable thallium form as Tl(III)) was to prove that the presence of Tl(III) was not caused by the procedure of sample preparation itself, and that the whole analytical method provides reliable results. Choice of the method for conservation of the initial speciation, extraction with the highest efficiency and proving the correctness of the obtained data were the most difficult parts of the presented study. It was found that: both freezing and drying cause significant changes in the speciation of thallium; quantitative analysis could be performed only with fresh tissues of mustard plants; only short-term storage of an extract from fresh plant tissues is possible; the methodology is not the source of thallium (III); only the presence of DTPA can greatly limit the reduction of TI(III) to TI(I) (up to 1-3%); the UV irradiation results in disintegration of TI(III)DTPA in the presence of plant matrix (reduction up to 90%). Copyright © 2015 Elsevier Ltd. All rights reserved.

  6. Huge operation by energy gap of novel narrow band gap Tl1-x In1-x B x Se2 (B = Si, Ge): DFT, x-ray emission and photoconductivity studies

    Science.gov (United States)

    Piasecki, M.; Myronchuk, G. L.; Zamurueva, O. V.; Khyzhun, O. Y.; Parasyuk, O. V.; Fedorchuk, A. O.; Albassam, A.; El-Naggar, A. M.; Kityk, I. V.

    2016-02-01

    It is shown that narrow band gap semiconductors Tl1-x In1-x GexSe2 are able effectively to vary the values of the energy gap. DFT simulations of the principal bands during the cationic substitutions is done. Changes of carrier transport features is explored. Relation with the changes of the near the surface states is explored . Comparison on a common energy scale of the x-ray emission Se Kβ 2 bands, representing energy distribution of the Se 4p states, indicates that these states contribute preliminary to the top of the valence band. The temperature dependence of electrical conductivity and spectral dependence photoconductivity for the Tl1-x In1-x Ge x Se2 and Tl1-x In1-x Si x Se2 single crystals were explored and compared with previously reported Tl1-x In1-x Sn x Se2. Based on our investigations, a model of centre re-charging is proposed. Contrary to other investigated crystals in Tl1-x In1-x Ge x Se2 single crystals for x = 0.1 we observe extraordinarily enormous photoresponse, which exceed more than nine times the dark current. X-ray photoelectron core-level and valence-band spectra for pristine and Ar+-ion irradiated surfaces of Tl1-x In1-x GexSe2 (x = 0.1 and 0.2) single crystals have been studied. These results indicate that the relatively low hygroscopicity of the studied single crystals is typical for the Tl1-x In1-x Ge x Se2 crystals, a property that is very important for handling these quaternary selenides as infrared materials operating at ambient conditions.

  7. The Circuit-Level Decoupling Modulation Strategy for Three-Level Neutral-Point-Clamped (TL-NPC) Inverter

    DEFF Research Database (Denmark)

    Zhang, Zhe; Thomsen, Ole Cornelius; Andersen, Michael A. E.

    2011-01-01

    In this paper, a circuit-level decoupling modulation strategy is proposed for the three-level (TL) neutral-point-clamped (NPC) inverters. With the proposed modulation scheme, the TL-NPC inverter can be decoupled into two three-level Buck converters in each defined operating section, which makes...

  8. Applications of a pnCCD detector coupled to columnar structure CsI(Tl) scintillator system in ultra high energy X-ray Laue diffraction

    Science.gov (United States)

    Shokr, M.; Schlosser, D.; Abboud, A.; Algashi, A.; Tosson, A.; Conka, T.; Hartmann, R.; Klaus, M.; Genzel, C.; Strüder, L.; Pietsch, U.

    2017-12-01

    Most charge coupled devices (CCDs) are made of silicon (Si) with typical active layer thicknesses of several microns. In case of a pnCCD detector the sensitive Si thickness is 450 μm. However, for silicon based detectors the quantum efficiency for hard X-rays drops significantly for photon energies above 10 keV . This drawback can be overcome by combining a pixelated silicon-based detector system with a columnar scintillator. Here we report on the characterization of a low noise, fully depleted 128×128 pixels pnCCD detector with 75×75 μm2 pixel size coupled to a 700 μm thick columnar CsI(Tl) scintillator in the photon range between 1 keV to 130 keV . The excellent performance of the detection system in the hard X-ray range is demonstrated in a Laue type X-ray diffraction experiment performed at EDDI beamline of the BESSY II synchrotron taken at a set of several GaAs single crystals irradiated by white synchrotron radiation. With the columnar structure of the scintillator, the position resolution of the whole system reaches a value of less than one pixel. Using the presented detector system and considering the functional relation between indirect and direct photon events Laue diffraction peaks with X-ray energies up to 120 keV were efficiently detected. As one of possible applications of the combined CsI-pnCCD system we demonstrate that the accuracy of X-ray structure factors extracted from Laue diffraction peaks can be significantly improved in hard X-ray range using the combined CsI(Tl)-pnCCD system compared to a bare pnCCD.

  9. The preliminary application of OSL in comparison with TL for authentication of ancient Chinese bricks

    International Nuclear Information System (INIS)

    Leung, P.L.; Tang Qiang; Li, Mike; Zhang Chunxiang

    2005-01-01

    The single-aliquot regenerative-dose (SAR) protocol with optically stimulated luminenscence (OSL) was applied to measure the equivalent dose (ED) of ancient Chinese bricks ranging in age from 180 to 1600 years. In the protocol, sensitivity changes can be corrected by using OSL response to a fixed test dose during measurement. For comparative study between OSL and TL, thermoluminescence (TL) measurement procedures were also applied to determine the paleodose of the bricks. Both results of OSL and TL are in agreement with the known ages of the bricks, and the paleodose ratios(ED OSL / ED TL ) are between 0.96 and 1.21, mean value 1.08+/-0.02. The annual doses of the bricks, estimated by the paleodoses and the known ages, range from 5.07 to 6.79mGy/a, comparable with the measured annual dose values of the bricks. Therefore, it is concluded that the SAR protocol is a rapid and effective OSL technique to authenticate Chinese bricks

  10. A comparative study between OSL and TL techniques for the dating of ancient chinese bricks

    International Nuclear Information System (INIS)

    Leung, P.L.; Li, M.; Tang Qiang; Zhang Chunxiang

    2004-01-01

    The single-aliquot regenerative-dose (SAR) protocol to the optically stimulated luminescence (OSL) was applied to measure the paleodose of ancient Chinese bricks with an age range from 180 to 1600 years. In the protocol, sensitivity changes can be corrected by using OSL response to a fixed test dose during measurement. For comparative study between OSL and TL, thermoluminescence (TL) measurement procedures were also applied to determine the paleodose of the bricks. Both results of OSL and TL are in good agreement with, and the paleodose ratios (De OSL /De TL ) are between 0.96 and 1.21, with a mean value of 1.08 ± 0.07. The annual dose of the bricks, estimated by the paleodoses and the known ages, ranges from 5.07 to 6.85 mGy/a, comparable with the measured annual dose values. Therefore, it is concluded that the SAR protocol is a rapid and effective OSL technique to authenticate Chinese bricks. (authors)

  11. TL, OSL and C-14 dating results of the sediments and bricks from mummified nuns' grave

    International Nuclear Information System (INIS)

    Tudela, Diego R.G.; Tatumi, Sonia H.; Yee, Marcio; Brito, Silvio L.M.

    2012-01-01

    This paper presents the results of TL and OSL dating of soil and fragments of bricks from a grave, which was occupied by two mummified nuns, found at 'Luz' Monastery, located in the state of Sao Paulo, Brazil. The TL and OSL ages were compared to C-14 dating ones obtained from bone collagens of the mummies. The majority of the ages is related to the eighteenth century. The gamma-ray spectroscopy was used to evaluate natural radioisotope concentrations in the samples, and by using these concentrations the annual dose rates, from 3.0 to 5.3 Gy/kyr, were obtained. Neutron activation analysis was performed and the radioisotope contents results are in agreement with those obtained by gamma-ray spectroscopy. The contents of U, Th and Ce elements were higher than those found in usual sediments. (author)

  12. On the Mechanisms of Formation of Memory Channels and Development of Negative Differential Resistance in Solid Solutions of the TlInTe2-TlYbTe2 System

    Science.gov (United States)

    Akhmedova, A. M.

    2018-04-01

    The behavior of an electronic subsystem is investigated in the course of formation and development of a memory channel in solid solutions of the TlInTe2-TlYbTe2 system. An analysis of the current-voltage characteristics allows getting an insight into the reason for a sharp change in electrical conductance of the specimens under study during their transition from the high-resistance to high-conductance state and the reasons for the well known instability of threshold converters, which makes it possible to design devices with high threshold voltage stability.

  13. Radiation exposure around patients after 201Tl-myocardial scintigraphy

    International Nuclear Information System (INIS)

    Kurtaran, A.; Preitfellner, J.; Kohoutek, D.; Tousek, A.; Virgolini, I.; Havlik, E.

    1997-01-01

    Aim: It was the aim of the study to assess the additional radiation exposure to patients, attendents and nurses by patients who are undergoing nuclear medicine investigations (myocardial scintigraphy) with 201 Tl-chloride ( 201 Tl-Cl). Methode: In 16 cases the dose rates at 0.5, 1 and 2 m distance from patients were measured at 0.5, 1.5, 3-4 and 24, in some cases until 370 h after administration of 100±10 MBq 201 Tl-Cl. From the time courses of the dose rates around the patients the possible radiation exposure of other persons were estimated. Results: The initial values of the dose rate were 3.82 μSv/h at 0.5 m, 1.18 μSv/h at 1 m and 0.30 μSv/h at 2 m distance from the patients respectively. The dose rates were decreasing following a monoexponential course with an effective half-life of 60 h. The maximum doses to other persons at 1 m distance from the patients were determined by considering three scenarios. The values were 13 μSv in the waiting room, 26 μSv for nurses working in the ward and 105 μSv for persons living in the same household. Conclusion: Even at very restrictive assumptions the doses were far below the maximum permissible dose to non-radiation workers set by radiation protection regulations (1.5 mSv per year). (orig.) [de

  14. Correlation between TL and OSL signals in KMgF3:Ce3+: Bleaching study of individual glow-peaks

    International Nuclear Information System (INIS)

    Dallas, G.I.; Polymeris, G.S.; Afouxenidis, D.; Tsirliganis, N.C.; Tsagas, N.F.; Kitis, G.

    2010-01-01

    KMgF 3 :Ce 3+ is an ultra sensitive Thermoluminescence (TL) material with a complex TL and OSL glow-curve structure. The aim of the present work is to attempt a one-to-one correspondence between specific TL glow-peaks and OSL components in KMgF 3 :Ce 3+ . The correlation study involves the deconvolution of the TL curves and the estimation of the bleaching decay constants for individual glow-peaks followed by the deconvolution of the LM-OSL curve using the estimated decay constants. It was found that the bleaching of each individual glow-peak takes place in three different rates; namely in a fast, medium and slow rate.

  15. Determination of the burn-up in fuels of the MTR type by means of gamma spectroscopy with crystal of INa(Tl)

    International Nuclear Information System (INIS)

    Kestelman, A.J.

    1988-01-01

    One of the responsibilities of the Laboratory of Analysis by Neutronic Activation of the RA-6 reactor is to determine the burn-up in fuels of the MTR type. In order to gain experience, up to the arrival of the hyperpure Germanium detector (HPGe) to be used in normal operation, preliminary measurements with a crystal of INa(Tl) were made. The fuel elements used are originated in the RA-3 reactor, with a decay superior to the thirteen years. For this reason, the unique visible photoelectric peak is the one of Cs-137, owing to the low resolution of the INa(Tl). After preliminary measurements, the profiles of burn-up, rectified by attenuation, were measured. Once the efficiency of the detector was determined, the calculation of the burn-up was made; for the element No. 144, a value of 21.6 ± 2.9 g was obtained to be compared with the value 21.9 g which was the evaluation made by the operators. (Author) [es

  16. The molecular, electronic, bonding, and photophysical features of the [(c-Pt3)Tl(c-Pt3)]+ inorganic metallocenes.

    Science.gov (United States)

    Tsipis, Athanassios C; Gkekas, George N

    2013-06-21

    The molecular, electronic, bonding and photophysical properties of a series of inorganic metallocenes with the general formula {[Pt3(μ2-L)3(L')3]2(μ6-Tl)}(+) (L = CO, CH3CN, PH2, C6F5, or SO2 and L' = CO, PH3, CH3CN, C6F5) have been studied by means of DFT electronic structure calculations. The estimated Tl-cd distances between Tl(+) cations and the centroids (cd) of the trimetallic Pt3(μ2-L)3(L')3 {3 : 3 : 3} decks were found in the range 2.932-3.397 Å. The predicted bond dissociation energy, D0, of the (c-Pt3)···Tl(+) bonds was found to lie within the range -31.5 up to -77.5 kcal mol(-1) at the B3LYP/LANL2TZ(f)(Pt) ∪ 6-31G(d,p)(E) ∪ SRLC(Tl) level of theory. Most of the [(c-Pt3)Tl(c-Pt3)](+) inorganic metallocenes adopt a bend titanocene-like structure. The Localized Orbital Locator (LOL) contour maps along with the 3D contour plots of the Reduced Gradient Density (RDG) mirror the composite nature of the interaction of Tl(+) with the triangular Pt3 metallic ring cores consisting of electrostatic, covalent and dispersion interaction components. The Pt3···Tl(+)···Pt3 bonding mode was further validated by Energy Decomposition Analysis (EDA) calculations which demonstrated that the electrostatic and covalent components of the interaction contribute almost equally to the bonding interactions. Furthermore, Charge Decomposition Analysis (CDA) and Natural Bond Orbital Analysis (NBO) calculations indicated that charge transfer from the Tl(+) cation to the Pt3(0) {3 : 3 : 3} decks also occurs. The {[Pt3(μ2-L)3(L')3]2(μ6-Tl)}(+) sandwiches absorb in the UV-Vis region (300-500 nm) and emit in the visible-near IR region (600-1000 nm). The absorption bands are mainly of MLCT/MC character while phosphorescence is predicted to occur via the first triplet excited state, T1, since the spin density of this excited state could be described as a SOMO - 1/SOMO combination. Generally, no significant distortions occur upon excitation of these systems

  17. Silicon drift detectors coupled to CsI(Tl) scintillators for spaceborne gamma-ray detectors

    International Nuclear Information System (INIS)

    Marisaldi, M.; Fiorini, C.; Labanti, C.; Longoni, A.; Perotti, F.; Rossi, E.; Soltau, H.

    2006-01-01

    Silicon Drift Detectors (SDDs), thanks to their peculiar low noise characteristics, have proven to be excellent photodetectors for CsI(Tl) scintillation light detection. Two basic detector configurations have been developed: either a single SDD or a monolithic array of SDDs coupled to a single CsI(Tl) crystal. A 16 independent detectors prototype is under construction, designed to work in conjunction with the MEGA Compton telescope prototype under development at MPE, Garching, Germany. A single SDD coupled to a CsI(Tl) crystal has also been tested as a monolithic detector with an extended energy range between 1.5 keV and 1 MeV. The SDD is used as a direct X-ray detector for low energy photons interacting in silicon and as a scintillation light photodetector for photons interacting in the crystal. The type of interaction is identified by means of pulse shape discrimination technique. Detectors based on an array of SDDs coupled to a single CsI(Tl) crystal have also been built. The readout of these detectors is based on the Anger camera technique, and submillimeter spatial resolution can be achieved. The two detectors' approaches and their applications will be described

  18. Structure of β-TlMo2P3O13

    International Nuclear Information System (INIS)

    Costentin, G.; Borel, M.M.; Grandin, A.; Leclaire, A.; Raveau, B.

    1991-01-01

    Thallium molybdenum triphosphate, TlMo 2 P 3 O 13 , M r =679.16, monoclinic, P2 1 /c, a=9.7536 (3), b=19.0640 (16), c=6.3945 (7) A, β=107.099 (7) 0 , V=1136 (2) A 3 , Z=4, D m not measured, D x =4.08 Mg m -3 , λ(MoKα)=0.71073 A, μ=16.90 mm -1 , F(000)=314, T=293 K, 951 reflections, R=0.047, ωR=0.047. The lattice is built up from MoO 6 , PO 4 and P 2 O 7 groups delimiting tunnels where the Tl + ions are located. The title compound is isotyopic with β-KMo 2 P 3 O 13 . (orig.)

  19. 201Tl-redistribution analysis in early and delayed myocordial scintigrams of patients with coronary heart disease (CHD)

    International Nuclear Information System (INIS)

    Hoer, G.; Sebening, H.; Sauer, E.; Dressler, J.; Lutilsky, L.; Wagner-Manslau, C.; Bofilias, I.; Technische Univ. Muenchen

    1979-01-01

    Scans were performed on 8 healthy subjects and 25 with coronary heart disease proven by angiography and ventriculography including 6 with previous myocardial infarction at rest, exercise, and 1 and 2 h after exercise. Data were collected by a gamma camera interfaced to a data collection system. In healthy subjects 201 Tl distribution was homogeneous at rest and after exercise, the count rate ranging between 100% - as set in the region of maximum - and 80% over other regions of myocardium. In 19 patients with coronary heart disease it was uniform only at rest; 6 patients with previous myocardial infarction had locally diminished 201 Tl uptake even at rest. In patients with coronary heart disease without previous myocardial infarction, scans made immediately after exercise showed significant 201 Tl hypofixation in region of minimum, the count rate of which was less than 80% of the count rate as determined over region of maximum, 201 Tl uptake. Scans made 1 and 2 h after exercise had filling-in of 201 Tl within the region of minimum the count rate of which returned to the normal range of at least 80% of the count rate measured over region of maximum uptake. This return to resting distribution was called 201 Tl redistribution. Six patients with coronary heart disease and previous myocardial infarction had 201 Tl defects larger after exercise than at rest, without redistribution being observed. Redistribution in late postexercise scans is a sign of reversible ischemia in coronary heart disease. Scans at rest may be omitted in coronary heart disease, because transient ischemia is undetectable, unless spontaneous angina occurs during scan procedure. (orig.) [de

  20. Effect of deep native defects on ultrasound propagation in TlInS{sub 2} layered crystal

    Energy Technology Data Exchange (ETDEWEB)

    Seyidov, MirHasan Yu., E-mail: smirhasan@gtu.edu.tr [Department of Physics, Gebze Technical University, 41400 Gebze, Kocaeli (Turkey); Institute of Physics of NAS of Azerbaijan, H. Javid Avenue, 33, AZ-1143 Baku (Azerbaijan); Suleymanov, Rauf A. [Department of Physics, Gebze Technical University, 41400 Gebze, Kocaeli (Turkey); Institute of Physics of NAS of Azerbaijan, H. Javid Avenue, 33, AZ-1143 Baku (Azerbaijan); Odrinsky, Andrei P. [Institute of Technical Acoustics, National Academy of Sciences of Belarus, Lyudnikov Avenue 13, Vitebsk 210717 (Belarus); Kırbaş, Cafer [Department of Physics, Gebze Technical University, 41400 Gebze, Kocaeli (Turkey); The Scientific and Technological Research Council of Turkey, National Metrology Institute (TUBITAK UME), PQ 54 41470 Gebze, Kocaeli (Turkey)

    2016-09-15

    We have investigated p-type semiconductor–ferroelectric TlInS{sub 2} by means of Photo-Induced Current Transient Spectroscopy (PICTS) technique in the temperature range 77–350 K for the detection of native deep defect levels in TlInS{sub 2}. Five native deep defect levels were detected and their energy levels and capture cross sections were evaluated. Focusing on these data, the influence of these defects on the longitudinal and transverse ultrasound waves propagation as well as the effect of electric field on ultrasound waves were studied at different temperatures. The acoustic properties were investigated by the pulse-echo method. The direct contribution of thermally activated charged defects to the acoustic properties of TlInS{sub 2} was demonstrated. The key role of charged native deep level defects in elastic properties of TlInS{sub 2} was shown.

  1. Assessment of myocardial viability by exercise stress myocardial tomography with 201Tl

    International Nuclear Information System (INIS)

    Narita, Michihiro; Kurihara, Tadashi; Murano, Kenichi; Usami, Masahisa

    1992-01-01

    Exercise stress (Ex) and redistribution (RD) myocardial tomography with Tl-201 has been widely used for evaluating myocardial viability. But recent studies have demonstrated that reinjection (ReI) study following RD study is necessary for detecting reversible ischemic myocardium. On the other hand, decreased myocardial washout of Tl-201 after Ex is an indicator of myocardial ischemia. So we have studied the usefulness of myocardial Tl-201 washout rate (WOR) for the evaluation of myocardial viability by comparing it with ReI images. Ex and RD myocardial tomographies were obtained immediately after Ex and 3 hours later. After RD study a small amount of Tl-201 was injected and ReI imaging was repeated. We studied 64 myocardial segments (in 58 patients with coronary artery disease) in which Ex-induced perfusion defects persisted in RD images. According to the changes of perfusion defects between Ex, RD and ReI images, they were classified into 3 types: Type I; perfusion defect on the RD image was identical to ReI image (75%). Type I was divided into 2 subgroups whether perfusion defect at Ex was unchanged (Ia, 42%) or improved (Ib, 33%) on the RD image. Type II; perfusion defect at Ex was reduced on the RD image and it improved furthermore at ReI image (17%). Type III; perfusion defect was the same at Ex and RD but it was reduced on the ReI image (8%). WOR less than 30% was defined as abnormal when Ex heart rate exceeded 120 bpm and lung-myocardial Tl-201 uptake ratio was less than 0.45. The differentiation between Type Ia and Type III is of great importance. History of myocardial infarction, effort angina and Ex induced ST depression could not differentiate these 2 groups. WOR abnormality was observed in all of Type III, but WOR was normal in Type Ia. In conclusion, WOR abnormality in Ex-RD myocardial imaging is useful for evaluating myocardial viability. ReI imaging is necessary for the precise evaluation of viable muscle mass and for inadequate Ex. (author)

  2. Spectrum analysis with indoor multi-channels gamma-rays spectrometer (NaI(Tl))

    International Nuclear Information System (INIS)

    Hou Shengli; Fan Weihua

    2005-01-01

    Two calculational methods for analyzing the spectrum which measured by indoor low background multi-channels gamma-rays spectrometer (Na(Tl)) to get the specific activity of 226 Ra, 232 Th and 40 K of the sample are discussed, they are the spectrum analysis method and the characteristic energy peak method (inverse matrix method) respectively. The sample spectrum are analyzed with the program designed according to the two methods, and compared with the results by HPGe gamma-rays spectrometer, showing that the relative deviation is ≤10% with the two methods. (authors)

  3. Dependence of NaI(Tl) detector intrinsic efficiency on source ...

    Indian Academy of Sciences (India)

    on source–detector distance, energy and off-axis distance: Their ... This d/R value at which minimum efficiency occurs approaches zero as off- axis distance ... It should be noted at this point that from the point of view of radiation protection ...

  4. Characterization of deep level defects and thermally stimulated depolarization phenomena in La-doped TlInS2 layered semiconductor

    International Nuclear Information System (INIS)

    Seyidov, MirHasan Yu.; Suleymanov, Rauf A.; Mikailzade, Faik A.; Kargın, Elif Orhan; Odrinsky, Andrei P.

    2015-01-01

    deep level defects, are aligned in the direction of the applied electric field and the equilibrium polarization can be reached in a relatively short time. When the polarization field is maintained, while cooling the temperature of sample to a sufficiently low degrees, the relaxation times of the aligned dipoles drastically increases. Practically, frozen internal electric field or electrets states remain inside the TlInS 2 :La when the applied bias field is switched off. The influence of deep level defects on TSDC spectra of TlInS 2 :La has been revealed for the first time

  5. Dating archeological ceramics from the Valley of Vitor, Arequipa by the TL method

    Science.gov (United States)

    Cano, N. F.; Arizaca, E. C.; Yauri, J. M.; Arenas, J. S. A.; Watanabe, S.

    The age of some ancient pottery from the Valley of Vitor in the region of Arequipa, Peru, is determined by the thermoluminescence (TL) method. For dating, a 325 °C TL peak was used and irradiation with γ-dose from 5 to 50 Gy was carried out for the additive method, and from 0.4 to 5 Gy for the regeneration method. For these dose values, the TL intensity is observed to grow linearly, obtaining an accumulated dose of 1.62±0.09 Gy and 1.36±0.03 Gy for the additive and regeneration methods, respectively. The age (A) of the sample was calculated by the two methods, being A=867±195 years after Christ (AC) for the additive method and A=1050±157 years AC for the regeneration method. Both results are within 800-1200 years AC, which is the period of the Wari culture.

  6. Sequential change of cardiomyopathy of Duchenne muscular dystrophy by 201Tl myocardial SPECT

    International Nuclear Information System (INIS)

    Ono, Seiji; Sugimoto, Seiichirou; Inoue, Kenjirou; Jinnouchi, Seishi; Hoshi, Hiroaki; Watanabe, Katsushi.

    1989-01-01

    201 Tl myocardial SPECT were performed to evaluate of cardiomyopathy in Duchenne type of progressive muscular dystrophy (DMD). Follow up SPECT images of the same patients were also obtained about 1 year after the first scan. Cases subjected to study were 10 DMD. At the first study the hypoperfusion area of the left ventricular muscle were observed in 6 cases (60%) out of 10. At the second study the hypoperfusion areas became wider and lower in 4 out of 6 cases (66.7%). The new hypoperfusion area which was not demonstrated at the first study was observed at the second study in one case of these cases. These results suggested that the positive rate of cardiomyopathy in DMD by 201 Tl myocardial SPECT was high, and 201 Tl myocardial SPECT is a useful examination to detect the change of myocardial damage in DMD. (author)

  7. Tl response of KMgF3 :Lu+PTFE depending on the dose of gamma radiation of 60Co

    International Nuclear Information System (INIS)

    Lopez, A.; Gonzalez, P.R.; Furetta, C.; Azorin, J; Rivera, T.; Sepulveda, F.

    2002-01-01

    Due to the great interest in Tl dosimetry for measuring the levels of radiation doses, as environmental as in the different medical radiation applications in different laboratories of the World it is continued in the searching of new Tl materials with optimum dosimetric characteristics and low cost. In this work the obtained results when irradiating Tl dosemeters of KMgF 3 :Lu + PTFE with gamma radiation of 60 Co are presented. Such results showed that this material presents linearity of response depending on the dose between 0.016 to 100 Gy. Although it is continued with the characterization tests it is able to say that this Tl new material can be used for dosimetric aims. (Author)

  8. Immunity against mouse thymus-leukemia antigen (TL) protects against development of lymphomas induced by a chemical carcinogen, N-butyl-N-nitrosourea.

    Science.gov (United States)

    Tsujimura, Kunio; Obata, Yuichi; Matsudaira, Yasue; Ozeki, Satoshi; Taguchi, Osamu; Nishida, Keiko; Okanami, Yuko; Akatsuka, Yoshiki; Kuzushima, Kiyotaka; Takahashi, Toshitada

    2004-11-01

    Mouse thymus-leukemia antigens (TL) are aberrantly expressed on T lymphomas in C57BL/6 (B6) and C3H/He (C3H) mice, while they are not expressed on normal T lymphocytes in these strains. When N-butyl-N-nitrosourea (NBU), a chemical carcinogen, was administered orally to B6 and C3H strains, lymphoma development was slower than in T3(b)-TL gene-transduced counterpart strains expressing TL ubiquitously as self-antigens, suggesting that anti-TL immunity may play a protective role. In addition, the development of lymphomas was slightly slower in C3H than in B6, which seems to be in accordance with the results of skin graft experiments indicating that both cellular and humoral immunities against TL were stronger in C3H than B6 mice. The interesting finding that B lymphomas derived from a T3(b)-TL transgenic strain (C3H background) expressing a very high level of TL were rejected in C3H, but not in H-2K(b) transgenic mice (C3H background), raises the possibility that TL-specific effector T cell populations are eliminated and/or energized to a certain extent by interacting with H-2K(b) molecules.

  9. Evaluation of Tl-201 SPECT imaging findings in prostate cancer

    Directory of Open Access Journals (Sweden)

    Sinem Ozyurt

    2015-07-01

    Full Text Available Objectives: To compare with histopathological findings the findings of prostate cancer imaging by SPECT method using Tl-201 as a tumor seeking agent. Methods: The study comprised 59 patients (age range 51-79 years, mean age 65.3 ± 6.8 years who were planned to have transrectal ultrasonography (TRUS-guided biopsies due to suspicion of prostate cancer between April 2011 and September 2011. Early planar, late planar and SPECT images were obtained for all patients. Scintigraphic evaluation was made in relation to uptake presence and patterns in the visual assessment and to Tumor/Background (T/Bg ratios for both planar and SPECT images in the quantitative assessment. Histopathological findings were compatible with benign etiology in 36 (61% patients and malign etiology in 23 (39% patients. Additionally, comparisons were made to evaluate the relationships between uptake patterns,total PSA values and Gleason scores. Results: A statistically significant difference was found between the benign and malignant groups in terms of uptake in planar and SPECT images and T/Bg ratios and PSA values. No statistically significant difference was found between uptake patterns of planar and SPECT images and Gleason scores in the malignant group. Conclusions: SPECT images were superior to planar images in the comparative assessment. Tl-201 SPECT imaging can provide an additional contribution to clinical practice in the diagnosis of prostate cancer and it can be used in selected patients.

  10. Evidences for the Formation of Chromium in the Unusual Oxidation State Cr(IV). I. Chemical Reactivity, Microhomogeneity, and Crystal Structures of the Nonstoichiometric Channel Compounds Tl xCr 5Se 8(0 ≤ x≤ 1)

    Science.gov (United States)

    Bensch, W.; Helmer, O.; Näther, C.

    1996-11-01

    The topotactic redox reaction between TlCr 5Se 8and bromine in acetonitrile leads to the formation of metastable samples with 0 ≤ xtransition metal chalcogenide crystallizing in the TlV 5S 8type structure with a Tl content xtopotactic redox reaction does not follow simple kinetics but is rather explained on the basis of the superposition of at least three different fundamental steps. EDAX investigations conducted on selected single crystals reveal that dependent on the deintercalation temperature, Tl is laterally inhomogeneous distributed along the needle axis which coincides with the crystallographic baxis. A pronounced maximum is observed at the middle of the crystals. In stoichiometric TlCr 5Se 8the detailed analysis of the anisotropic displacement parameters of the Tl atoms reveal that the Tl atoms are displaced from the central position by about 0.26 Å. As a consequence the Tl atoms are coordinated by seven Se atoms in an irregular coordination polyhedron. Since the positions x0 zare related by a center of symmetry they cannot be occupied simultaneously. Hence it must be assumed that TlCr 5Se 8has a domain structure with local symmetry Cm. In the Tl poorer phases the refinement of the Tl atoms at the central position leads to unusual high U22components. The observed microinhomogenity as well as an enhanced mobility and/or static disorder of the Tl atom within the channel may be responsible for this. The value for U11decreases with decreasing Tl content whereas U33is not affected. This observation is indicative for a different displacement of the Tl atoms from the central position. With respect to the possible reaction mechanisms, according to our structural investigations, the oxidation of monovalent Tl to trivalent Tl can be excluded. With decreasing Tl content the lattice parameters exhibit very anisotropic behavior, which is a direct consequence of the large changes of the interatomic Cr-Cr distances. The average as well as the nonbonding Se-Se distances

  11. On clinical usefulness of Tl-201 scintigraphy for the management of malignant soft tissue tumors

    International Nuclear Information System (INIS)

    Terui, Shoji; Terauchi, Takashi; Abe, Hiroyuki; Fukuma, Hisatoshi; Beppu, Yasuo; Chuman, Koichi; Yokoyama, Ryohei

    1994-01-01

    The purpose of this study was to investigate Tl-201 as a tumor scanning agent in patients with malignant soft tissue sarcomas and to establish the sensitivity of this type of scintigraphy concerning local recurrences or metastases that may remain clinically suspected. Seventy-eight patients with malignant soft tissue sarcomas and 22 with benign soft tissue tumors were studied. Of these 78 malignant soft tissue sarcomas patients, the sensitivity of Tl-201 (81.2%) was higher than that of Ga-67 (68.8%). Thirty-three out of 78 patients received a total of 95 consecutive scintigraphic follow-up examinations. Therapeutic effects was assessed by comparing the results of Tl-201 examinations with the clinical findings. Of these 33 patients, the therapeutic effects observed were as follows: complete remission 1, partial remission 8, progress of disease 1, and no remarkable change 23. Tl-201 scintigraphy has proved itself very useful not only in clinically detecting the malignant soft tissue sarcomas and in assessing therapeutic effects on these diseases, but also in assessing the follow-up patients with malignant soft tissue sarcomas. (author)

  12. Dosimetric characteristics of Li2B4O7:Cu,Ag,P solid TL detectors

    International Nuclear Information System (INIS)

    Proki, M.

    2002-01-01

    The main dosimetric characteristics are presented of newly prepared tissue-equivalent, highly sensitive thermoluminescent detector, Li 2 B 4 O 7 :Cu,Ag,P in the form of sintered pellets, developed at the Institute of Nuclear Sciences, Vin a . As a result of an advancement in the preparation procedure by the sensitising of basic copper activated lithium borate TL material, significant improvement in the TL sensitivity of Li 2 B 4 O 7 :Cu,Ag,P was gained. The glow curve of Li 2 B 4 O 7 :Cu,Ag,P consists of well defined main dosimetric peak situated at about 185-190 deg. C with the TL sensitivity which is about four to five times higher than that of LiF:Mg,Ti (TLD-100). From the experimental results a very wide linear dose response range, up to 10 3 Gy is evident. Dosimetric characteristics make sintered solid Li 2 B 4 O 7 :Cu,Ag,P TL detectors very promising for different dosimetry applications particularly in medical dosimetry and also for individual monitoring. (author)

  13. Development of source-less efficiency calibration procedure for CeBr3 based gamma spectrometry system

    International Nuclear Information System (INIS)

    Verma, Amit K.; Narayani, K.; Pant, Amar D.; Bhosale, Nitin; Anilkumar, S.; Palani Selvam, T.

    2018-01-01

    Scintillation spectrometers are widely used in detection and spectrometry of gamma photons. Sodium Iodide (NaI(Tl)) is the most commonly used scintillation detector for gamma ray spectrometry. However for portable application that require higher efficiency and better resolution Cerium Bromide (CeBr 3 ) crystals are more suitable than NaI(Tl) crystals. CeBr 3 detectors have high light output (∼ 68,000 photons/MeV), good proportionality, fast response and better energy resolution (<4% for 662 keV of 137 Cs), which makes it very promising detector for gamma ray spectrometry. In the present work, experimental and Monte Carlo based efficiencies for CeBr 3 detector for 137 Cs and 60 Co were evaluated

  14. Clinical use of /sup 201/Tl myocardial scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Senda, K; Imaeda, T; Kato, T; Asada, S; Doi, H

    1977-04-01

    Myocardial imaging with /sup 201/Tl and scinticamera was studied experimentally using specially designed phantoms and clinically in 23 patients with myocardial infarction or other heart disease. In the phantom experiment, quality of image, accumulative count rate, and detectability of the defect were compared to obtain the best technique for their detection, using four different collimators, i.e., converging, pin-hole, 4000-hole, and 140 keV high-resolution, at two photopeak levels of /sup 201/Tl of 75 and 167 keV, and combining a radiation absorber. In patient examination, myocardial images taken at different periods after injection, different detecting conditions of the scinticamera, and various detecting projections were compared. Images of the converging collimator at the 75 keV photopeak revealed considerably higher accumulative counts and relatively higher quality than those of other detecting conditions. It was necessary to take as many images as possible in various projections, in order to detect the location and size of the myocardial ischemic lesion because the lesion was demonstrated as a clear defect only in profile. It became evident that images taken between about 25 and 90 min delineated the myocardium more clearly than those taken in other periods. Normal images taken in 8 patients without ischemic heart disease appeared in the shape of a doughnut of horseshoe, demonstrating mainly the left venticular myocardium. The image was faint in the region of the aortic or mitral valve and thin in the region of the apical wall. A faint image of the right ventricular myocardium was sometimes seen. In 3 patients with valvular heart disease, findings suggested changes in the thickness of myocardium and the distribution of coronary blood flow. In 11 of 12 patients with old myocardial infarction, the location and size of the lesion was detected.

  15. Applicability of a portable CdTe and NaI (Tl) spectrometer for activity measure

    International Nuclear Information System (INIS)

    Fernandes, Jaquiel Salvi

    2005-02-01

    In this work it was studied the application of an in situ gamma spectrometer (ROVER) of Amptek Inc., composed by a Cadmium Telluride detector (CdTe) of 3 mm x 3 mm x 1 mm and a 30 mm x 30 mm Sodium Iodide detector doped with Thallium [NaI (Tl)). The radioactive sources used were type pastille, sealed in aluminum and polyethylene, of 241 Am, 133 Ba, 152 Eu, 3 sources of 137 Cs and soil samples contaminated with 137 Cs. It was performed a factorial planning 2 3 to optimize the in situ spectrometry system. This way it was determined that the best temperature for CdTe crystal operation is -22, deg C, with Shaping Time of 3 μS and Rise Time Discrimination (RTD) with value 3. With the help of the certified radioactive sources, we determined the efficiency curve of the two detectors. The CdTe detector was positioned at the standard distance of 1 meter of the sources and also at 4.15 cm. The NaI (Tl) detector was also positioned at the standard distance of 1 meter of the sources and at 2.8 cm. Measures were performed to determine the Minimum Detectable Activity (MDA) for both detectors. For the pastille type sources, the 137 Cs MDA for the CdTe detector at 4.15 cm, analyzing the energy line of 32 keV, was 6 kBq and at 1 meter of the 137 Cs source, analyzing the line of 661.65 keV, the MDA was 67 kBq. For soil samples, CdTe detector at 4.15 cm presented a MDA of 693 kBq.kg-l for the line of 32 keV, and for the soil sample 7 Be content the MDA found was 2867 Bq.kg -1 at 4.15 cm. For the NaI (Tl) detector, analyzing the line of 661.65 keV, the 137 Cs MDA for pastille type source at 1 meter of distance was 7 kBq, and for soil sample at 2.8 cm the measured 137 Cs MDA was 71 Bq.kg -1 . For the soil sample 7 Be content, at 2.8 cm of the Nal (Tl) detector, the obtained MDA was 91 Bq.kg -1 . Due to the minimum detectable activities found for the two detectors, we concluded that the employed in situ gamma ray spectrometer system allows the quantification of 137 Cs and 7 Be

  16. Monitoring of garbage with a 5 x 5 NaI (Tl) detector; Monitoreo de basura con un detector de NaI (Tl) de 5 x 5

    Energy Technology Data Exchange (ETDEWEB)

    Cortes P, A.; Becerril V, A.; Angeles C, A

    1991-12-15

    So far in that is carried out the first reload of nuclear fuel in the LVC, the monitoring of garbage has been carried out using monitors trade mark Eberline model RM 14. The procedure consists in manually monitoring each object and to separate of the considered 'clean' garbage the objects considered as contaminated, which register greater or equal counts to 100 cpm. This way to process was adequate under normal operation conditions, but not in the operation rhythm that implies a bigger maintenance since the time required for monitoring from 5 to 10 kg. of garbage is of the order of 0.5 hours and the production rhythm of this it ends up being a lot but high. Due to this necessity it was thought about the problem of looking by a more efficient monitoring method. In this work a method that uses a detector of NaI (Tl) of 5 x 5 inches is discussed. (Author)

  17. Monitoring of garbage with a 5 x 5 NaI (Tl) detector; Monitoreo de basura con un detector de NaI (Tl) de 5 x 5

    Energy Technology Data Exchange (ETDEWEB)

    Cortes P, A; Becerril V, A; Angeles C, A

    1991-12-15

    So far in that is carried out the first reload of nuclear fuel in the LVC, the monitoring of garbage has been carried out using monitors trade mark Eberline model RM 14. The procedure consists in manually monitoring each object and to separate of the considered 'clean' garbage the objects considered as contaminated, which register greater or equal counts to 100 cpm. This way to process was adequate under normal operation conditions, but not in the operation rhythm that implies a bigger maintenance since the time required for monitoring from 5 to 10 kg. of garbage is of the order of 0.5 hours and the production rhythm of this it ends up being a lot but high. Due to this necessity it was thought about the problem of looking by a more efficient monitoring method. In this work a method that uses a detector of NaI (Tl) of 5 x 5 inches is discussed. (Author)

  18. [Myocardial imaging in acute myocardial infarction using beta-methyl-p-(123I)-iodophenylpentadecanoic acid: comparison with 201Tl imaging and wall motion].

    Science.gov (United States)

    Naruse, H; Itano, M; Kondo, T; Kogame, T; Yamamoto, J; Morita, M; Kawamoto, H; Fukutake, N; Ohyanagi, M; Iwasaki, T

    1992-01-01

    Myocardial imaging using beta-methyl-p-(123I)-iodophenylpentadecanoic acid (BMIPP) was performed in 11 patients with acute myocardial infarction. The left ventricular images were divided into 12 segments, and myocardial imagings with BMIPP were compared with coronary angiography (CAG), thallium-201 myocardial scintigraphy (TL) and wall motion obtained by two-dimensional echocardiography (WM). When the culprit lesion was at the proximal point of the left anterior descending artery (LAD), all segments showed depressed uptake. In 3 cases with single vessel disease of the LAD, inferior wall of the basis showed reduced uptake of BMIPP despite the location of the culprit lesion. In cases with discordant uptake between the two tracers, BMIPP frequently showed more severely depressed uptake than TL in the subacute phase, although the uptake of BMIPP correlated with that of TL (tau = 0.82, p less than 0.001). In such cases, the discordance was related to the improvement in WM from the acute phase to the convalescent phase. BMIPP uptake correlated with WM in the subacute phase (tau = 0.50, p less than 0.001). BMIPP showed more severely depressed uptake while WM showed mild asynergy in most cases in which discordance was found between the BMIPP and WM findings. However, there was no correlation between the change in WM from the acute to subacute phases, or the uptakes of BMIPP and TL alone. We concluded that the myocardial condition can be evaluated in detail in acute myocardial infarction by comparing the findings of BMIPP with those of TL and WM.

  19. TL, OSL and C-14 dating results of the sediments and bricks from mummified nuns' grave

    Energy Technology Data Exchange (ETDEWEB)

    Tudela, Diego R.G.; Tatumi, Sonia H.; Yee, Marcio; Brito, Silvio L.M., E-mail: tatumi@fatecsp.br [Faculdades de Tecnologia de Sao Paulo (FATECs/CEETEPS/UNESP), Sao Paulo, SP (Brazil). Centro Estadual de Educacao Tecnologica Paula Souza; Morais, Jose L.; Morais, Daisy de; Piedade, Silvia C. [Universidade de Sao Paulo (USP), SP (Brazil). Museu de Arqueologia e Etnologia; Munita, Casimiro S.P.; Hazenfratz, Roberto [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2012-06-15

    This paper presents the results of TL and OSL dating of soil and fragments of bricks from a grave, which was occupied by two mummified nuns, found at 'Luz' Monastery, located in the state of Sao Paulo, Brazil. The TL and OSL ages were compared to C-14 dating ones obtained from bone collagens of the mummies. The majority of the ages is related to the eighteenth century. The gamma-ray spectroscopy was used to evaluate natural radioisotope concentrations in the samples, and by using these concentrations the annual dose rates, from 3.0 to 5.3 Gy/kyr, were obtained. Neutron activation analysis was performed and the radioisotope contents results are in agreement with those obtained by gamma-ray spectroscopy. The contents of U, Th and Ce elements were higher than those found in usual sediments. (author)

  20. Firing temperature of pottery using TL and OSL techniques

    International Nuclear Information System (INIS)

    Polymeris, G.S.; Sakalis, A.; Papadopoulou, D.; Dallas, G.; Kitis, G.; Tsirliganis, N.C.

    2007-01-01

    Several methods of thermal analysis are used to determine in the laboratory the firing temperature of ancient ceramic sherds. These methods are based primarily on changes of physical characteristics occurring when clay minerals are heated. The luminescence properties of quartz grains in a ceramic matrix also undergo certain changes during firing. The possibility of measuring the sensitivity change (sensitization) of quartz in order to determine the firing temperature of archeological ceramic artifacts was investigated. The sensitivity change was studied for both the thermoluminescence (TL) and the optically stimulated luminescence (OSL) signal for a ceramic sample of known firing temperature. Various segments of the sample were annealed to a different temperature. Subsequently, the initial sensitivity, as well as the thermal and the pre-dose sensitization were measured for both TL and OSL at room temperature as a function of the annealing temperature. The obtained TL glow curves showed different shapes for annealing temperatures above the firing temperature. Thermal and pre-dose sensitizations also exhibited a similar, although less prominent, rise. The OSL signal was analyzed by integrating the raw signal over the initial second of stimulation. The initial sensitivity showed an abrupt change for annealing temperatures around the firing temperature. An alternative approach used for the analysis of the OSL signal involved a full-component resolved sensitization study. The same abrupt change for the initial sensitivity of both the first and second components was observed, as well as, a clear but not very prominent thermal sensitization trend for annealing temperatures above the firing temperature

  1. Study of combinations of TL/OSL single dosimeters for mixed high/low ionization density radiation fields

    International Nuclear Information System (INIS)

    Oster, L.; Druzhyna, S.; Orion, I.; Horowitz, Y.S.

    2013-01-01

    In this paper we discuss and compare the potential application of combined OSL/TL measurements using 6 LiF:Mg,Ti (TLD-600 is enriched of isotope 6 Li which has a high cross-section for the reaction with slow neutrons) or 7 LiF:Mg,Ti ( TLD-700 is enriched of 7 Li isotope) and TLD-100 (natural isotopic composition) detectors. The OSL/TL duel readout of LiF:Mg,Ti as an ionization density discriminator avoids some of the difficulties inherent to the various types of discrimination mixed-field passive dosimeters, and in addition has several advantages. The preferential excitation of OSL compared to TL following high ionization density (HID) alpha irradiation, naturally explained via the identification of OSL with the “two-hit” F 2 or F 3 center, whereas the major component of composite TL glow peak 5 is believed to arise from a ''one-hit'' complex defect. This evidence allows near-total discrimination between HID radiation and low-ionization density (LID) radiation. Beta and alpha particle irradiations were carried out with 90 Sr/ 90 Y (∼500 keV average energy) and 241 Am sources (4.7 MeV) respectively and neutron irradiations were carried out at the PTB (Germany) (E n = 5 MeV) and RARAF (Columbia University, USA) (E n = 6 MeV) accelerator facilities. The highest values of the FOM obtained was ∼30 for neutron/gamma discrimination and ∼110 for alpha/gamma discrimination using OSL/TL – peak 5 measurements in TLD-700. -- Highlights: ► The increased response of OSL compared to TL following HID irradiation is observed. ► This evidence is explained via the identification of OSL with the ''two-hit'' F2 centers. ► The potential application of combined OSL/TL in discrimination dosimetry is discussed. ► The values of FOM were 110 for alpha/gamma and 30 for neutron/gamma discrimination

  2. Thallium speciation in plant tissues-Tl(III) found in Sinapis alba L. grown in soil polluted with tailing sediment containing thallium minerals.

    Science.gov (United States)

    Krasnodębska-Ostręga, Beata; Sadowska, Monika; Ostrowska, Sylwia

    2012-05-15

    Besides the dominant species in plants-Tl(I), noticeable amounts of Tl(III) (about 10% of total Tl content) were found in extracts of plants cultivated in the presence of tailing sediments, which are the main source of anthropogenic thallium already present in the environment. It is an important step of gaining knowledge about the detoxification mechanisms developed by Sinapis alba. This plant species is highly tolerant to Tl and it is able to cumulate high amounts of Tl and transport it into the above-ground organs. For more adequate estimation of accumulating abilities of S. alba, the elements' bioavailability was taken into consideration. The obtained bioconcentration factors of Cd (AF=0.6) and Zn (AF=1-2) were significantly lower than of Tl (AF=100-200). The biomass production was similar to the biomass of control cultivation. The results were based on ICP MS measurements of total elements' content and HPLC ICP MS for speciation analysis. The quality of obtained results was evaluated based on the intermethod comparison with voltammetry as a reference method. Comparison of data obtained using ICP MS and electrochemical methods (after a proper chemical treatment) was also used for indication of Tl(III) presence and for proving that Tl(I) was not transferred into Tl(III) during analytical procedures. Copyright © 2012 Elsevier B.V. All rights reserved.

  3. Comparison measure of natural radioactivity in environment specimen using HPGe and NaI(Tl) γ-ray spectrometer

    International Nuclear Information System (INIS)

    Zhou Chunlin; Han Feng; Li Tiantuo; Ma Wenyan; Di Yuming; Guo Huiping; Wu Yuelei

    2000-01-01

    The author reports the comparison results on natural radioactive nuclide contents of soil specimen from an uranium diggings with HPGe and NaI(Tl) γ-ray spectrometer. Relative method and athwart matrix method are used to analyze natural radioactive nuclide contents in samples of soil. The results are compared and are proven to be in accordance with each other

  4. Giant Tc shift in HgBa2CaCu2O6+δ and TlBa2CaCu2O7-δ superconductors due to Hg-Tl exchange

    International Nuclear Information System (INIS)

    Gapud, A.A.; Wu, J.Z.; Kang, B.W.; Yan, S.L.; Xie, Y.Y.; Siegal, M.P.

    1999-01-01

    The irreversibility lines of epitaxial thin films of HgBa 2 CaCu 2 O 6+δ and TlBa 2 CaCu 2 O 7-δ , whether deduced from field-induced magnetoresistive broadening or onset of nonhysteretic magnetization, were found to coincide when plotted against reduced temperature, showing the same exponential-decay temperature behavior for T/T c c >0.8 (where T c is zero-field, zero-resistivity critical temperature). These results indicate that replacing Tl with Hg has no noticeable effect on the anisotropy and suggests that T c is not determined by anisotropy. copyright 1999 The American Physical Society

  5. Statistics and the additive dose method in TL dating

    International Nuclear Information System (INIS)

    Scott, E.M.

    1988-01-01

    Estimation of the palaeo-dose and its associated error in thermoluminescence (TL) dating requires assumptions to be made concerning the error structures of both the TL signal and dose. In this paper, we consider the sensitivity of palaeo-dose estimation to different error structures and describe techniques for estimation of the resultant palaeo-dose errors. We also indicate how the validity of the assumptions may be verified. We have taken the approach that procedures for the analysis of a glow curve at a single temperature must first be proved prior to their inclusion in a full analysis of the glow curves over a series of temperatures. Thus, the paper deals mainly with the analysis of the univariate structure of glow curves, i.e. estimation of the palaeo-dose and error at each temperature, but in the final section of the paper, we discuss briefly the multivariate structure of the results including automatic detection of plateau regions. (author)

  6. Impact of intense x-ray pulses on a NaI(Tl)-based gamma camera

    Science.gov (United States)

    Koppert, W. J. C.; van der Velden, S.; Steenbergen, J. H. L.; de Jong, H. W. A. M.

    2018-03-01

    In SPECT/CT systems x-ray and γ-ray imaging is performed sequentially. Simultaneous acquisition may have advantages, for instance in interventional settings. However, this may expose a gamma camera to relatively high x-ray doses and deteriorate its functioning. We studied the NaI(Tl) response to x-ray pulses with a photodiode, PMT and gamma camera, respectively. First, we exposed a NaI(Tl)-photodiode assembly to x-ray pulses to investigate potential crystal afterglow. Next, we exposed a NaI(Tl)-PMT assembly to 10 ms LED pulses (mimicking x-ray pulses) and measured the response to flashing LED probe-pulses (mimicking γ-pulses). We then exposed the assembly to x-ray pulses, with detector entrance doses of up to 9 nGy/pulse, and analysed the response for γ-pulse variations. Finally, we studied the response of a Siemens Diacam gamma camera to γ-rays while exposed to x-ray pulses. X-ray exposure of the crystal, read out with a photodiode, revealed 15% afterglow fraction after 3 ms. The NaI(Tl)-PMT assembly showed disturbances up to 10 ms after 10 ms LED exposure. After x-ray exposure however, responses showed elevated baselines, with 60 ms decay-time. Both for x-ray and LED exposure and after baseline subtraction, probe-pulse analysis revealed disturbed pulse height measurements shortly after exposure. X-ray exposure of the Diacam corroborated the elementary experiments. Up to 50 ms after an x-ray pulse, no events are registered, followed by apparent energy elevations up to 100 ms after exposure. Limiting the dose to 0.02 nGy/pulse prevents detrimental effects. Conventional gamma cameras exhibit substantial dead-time and mis-registration of photon energies up to 100 ms after intense x-ray pulses. This is due PMT limitations and due to afterglow in the crystal. Using PMTs with modified circuitry, we show that deteriorative afterglow effects can be reduced without noticeable effects on the PMT performance, up to x-ray pulse doses of 1 nGy.

  7. Correlation of an abnormal rest /sup 201/Tl myocardial image: Pathological findings in cardiac transplant recipients

    Energy Technology Data Exchange (ETDEWEB)

    McKillop, J.H.; McDougall, I.R.; Billingham, M.; Schroeder, J.S.

    1982-06-01

    Rest myocardial /sup 201/Tl scintigraphy was undertaken in 15 males mean age 39 years (22-54) who had been accepted for cardiac transplantation. Complete pathological correlation was obtained in 14 after transplantation and in 1 who died before a suitable donor heart became available. The average time from scintigraphy to pathological evaluation was 42 days (9-103). All the /sup 201/Tl images were grossly abnormal and on the basis of these studies it was not possible to differentiate ischemic from idiopathic cardiomyopathy. Each of the three views of the /sup 201/Tl study was divided into three segments, therefore 135 areas were available for comparison (3 x 3 x 15). Eighty-eight of these were abnormal on scan and 78 of these were abnormal pathologically. The right ventricle was seen on all rest images but the degree of uptake bore no relationship to the measured thickness of the right ventricular wall. Structures such as the atrial wall and the enlarged papillary muscle were visualized in some patients. In two patients there was an improvement of the rest /sup 201/Tl image in delayed views and histologically these areas showed a mixture of muscle and fibrous tissue. The sensitivity of /sup 201/Tl imaging in this study was 89% and there was close correlation of the images with gross and microscopic pathological findings.

  8. Myocardial imaging with 201Tl at rest and during exercise. Comparison with coronary arteriography and resting and stress electrocardiography

    International Nuclear Information System (INIS)

    Ritchie, J.L.; Trobaugh, G.B.; Hamilton, G.W.; Gould, K.L.; Narahara, K.A.; Murray, J.A.; Williams, D.L.

    1977-01-01

    Myocardial imaging with intravenous thallium-201 ( 201 Tl) was performed at rest and following maximal treadmill exercise in 101 patients with suspected coronary artery disease. Results were interpreted from Polaroid scintiphotos by three independent observers with complete interobserver agreement in 79%. Of 25 patients with no or insignificant coronary artery disease ( 201 Tl image defect, one (4%) had an exercise 201 Tl defect, none had an ECG Q wave, and four (16%) had exercise ST-segment depression. Among 76 patients with coronary artery disease (greater than or equal to 50% diameter stenosis), 58 (76%) had a defect on either the rest or exercise 201 Tl image. The proportion of patients with an exercise image defect (50/76, 66%) was greater than the proportion with exercise ST depression alone (34/76, 45%; P 201 Tl is easily accomplished with readily available imaging equipment. The image data enhanced the diagnostic sensitivity of stress electrocardiography, and provided spatial identification of the abnormal segment(s) of myocardium

  9. Characterization of deep level defects and thermally stimulated depolarization phenomena in La-doped TlInS{sub 2} layered semiconductor

    Energy Technology Data Exchange (ETDEWEB)

    Seyidov, MirHasan Yu., E-mail: smirhasan@gyte.edu.tr; Suleymanov, Rauf A.; Mikailzade, Faik A. [Department of Physics, Gebze Technical University, Gebze, Kocaeli 41400 (Turkey); Institute of Physics of NAS of Azerbaijan, H. Javid ave. 33, Baku AZ-1143 (Azerbaijan); Kargın, Elif Orhan [Department of Physics, Gebze Technical University, Gebze, Kocaeli 41400 (Turkey); Odrinsky, Andrei P. [Institute of Technical Acoustics, National Academy of Sciences of Belarus, Lyudnikov ave. 13, Vitebsk 210717 (Belarus)

    2015-06-14

    , which are originated from the charged B5 deep level defects, are aligned in the direction of the applied electric field and the equilibrium polarization can be reached in a relatively short time. When the polarization field is maintained, while cooling the temperature of sample to a sufficiently low degrees, the relaxation times of the aligned dipoles drastically increases. Practically, frozen internal electric field or electrets states remain inside the TlInS{sub 2}:La when the applied bias field is switched off. The influence of deep level defects on TSDC spectra of TlInS{sub 2}:La has been revealed for the first time.

  10. How the sedimentary Re/Mo ratio and Tl enrichments trace past and present opaline productivity

    Science.gov (United States)

    Böning, Philipp; Brumsack, Hans-Jürgen

    2010-05-01

    preconcentration step for Mo on particles to explain the very low Re/Mo ratios, while Re only seems to accumulate via diffusion. However, our data suggest that the carrier phases are not Mn-oxides but fresh biogenic detritus. Further, since Mo and Cd are well correlated (Böning et al., 2004) our findings suggest a similar, biodetrital source for both elements. This would imply a non-conservative behaviour of Mo, which corroborates findings where dissolved Mo becomes depleted in coastal and open-ocean waters and consequently enriched on biogenic particles after algal blooms (Tuit and Ravizza, 2003; Dellwig et al. 2007). Concerning Tl, it is yet to be determined wether this element is directly associated with the opaline hard parts or the related fresh organic matter. However, the implied particle reactivity of Tl suggests a non-conservative behaviour of this element. Further, our data do not support an involvement of Tl with Mn but rather an association with biological cycling. References: Böning, P. et al. (2009) Mar. Geol. 259, 112-121; Böning, P. et al. (2004) Geochim. Cosmochim. Acta 68, 4429-4451; Crusius, J. et al. (1996) Earth Plan. Sci. Lett. 145, 65-78; Dellwig, O. et al. (2007) Geochim. Cosmochim. Acta 71, 2745-2761; Tuit, C. and Ravizza, G. (2003) Geochim. Cosmochim. Acta 67, A495, Suppl. 1; Wolf, A. (2002) Dissertation, University of Kiel, Germany, pp. 88.

  11. Measurement of conversion coefficients in 208Tl

    International Nuclear Information System (INIS)

    Wendling, F.

    1976-06-01

    A electron spectrometer composed by a Li drifted Si detector and a uniform magnetic field was constructed. The magnetic field is used to focus the electrons on the detector and to filter the other radiations. After the construction the instrument was calibrated in absolute eficience and was used together with a Ge(Li) spectrometer also calibrated, in the measurement of internal conversion coeficients of the 433 and 453 keV transitions in 208 Tl [pt

  12. Synthesis and in vivo evaluation of 201Tl(III)-DOTA complexes for applications in SPECT imaging

    NARCIS (Netherlands)

    Hijnen, N.M.; Vries, de A.; Blange, R.; Burdinski, D.; Grüll, H.

    2010-01-01

    Introduction The aim of this study was to assess the use of 201thallium3+ (201Tl3+) as a radiolabel for nuclear imaging tracers. Methods for labeling of 1,4,7,10-tetraazacyclododecane-N,N',N¿,N'¿ tetraacetic acid (DOTA) and diethylenetriaminepentaacetic acid (DTPA) chelators with 201Tl3+ were

  13. Formation pathways in the synthesis and properties of (Tl0.5Pb0.5)(Sr0.9Ba0.1)2Ca2Cu3Oz and (Tl0.5Pb0.5)(Sr0.8Ba0.2)2Ca2Cu3Oz-1223 superconductors

    International Nuclear Information System (INIS)

    Auinger, M; Gritzner, G; Bertrand, Ch; Galez, Ph; Soubeyroux, J-L

    2007-01-01

    The formation pathway of (Tl 0.5 Pb 0.5 )(Sr 0.9 Ba 0.1 ) 2 Ca 2 Cu 3 O z and (Tl 0.5 Pb 0.5 )(Sr 0.8 Ba 0.2 ) 2 Ca 2 Cu 3 O z was studied by neutron and x-ray diffraction. The following reaction pathway was proposed: thallium oxide and lead oxide react with Sr-rich (Sr 1-x Ca x )CuO 2 and Ca-rich (Ca x Sr 1-x )O to form Sr 4 Tl 2 O 7 and (Ca x Sr 1-x )PbO 3 , respectively. The thallate and the plumbate compounds then form the (Tl 0.5 Pb 0.5 )-1212 phase starting at a temperature of 600 deg. C. Finally, between 850 and 900 deg. C, the 1223 phase is formed from (Tl 0.5 Pb 0.5 )-1212 (Ca x Sr 1-x ) 2 CuO 3 and CuO. Parallel experiments to fabricate the (Tl, Pb)-1223 superconductor resulted in specimens with critical temperatures of 117.5 K and 116 K, respectively, and transition widths of 2 K. Differences between the pathways for the formation of Pb-doped, Sr-rich and Pb-free, Ba-rich Tl-1223 superconductors are discussed

  14. Enhancement of the superconducting properties of TlBa2CaCu2O7+δ thin films via postannealing

    International Nuclear Information System (INIS)

    Siegal, M.P.; Venturini, E.L.; Newcomer, P.P.; Morosin, B.; Overmyer, D.L.; Dominguez, F.; Dunn, R.

    1995-01-01

    The superconducting properties of TlBa 2 CaCu 2 O 7+δ (Tl-1212) films are greatly enhanced by annealing in unreactive ambients such as nitrogen at temperatures ranging from T a =250--600 degree C. The transition temperature, T c , of these Tl-1212 films as-grown in oxygen is 70 K. Annealing for 1 h at 250 degree C elevates T c above 90 K. T c further increases and sharpens for T a =600 degree C. In addition, subtle changes occur in the microstructure correlating with improved critical current density. These results indicate that Tl-1212 films may be of greater relevance for electronics applications than previously believed. copyright 1995 American Institute of Physics

  15. Tl response of LiF: Mg, Cu, P+Ptfe at X rays of 24, 42 and 100 KeV; Respuesta TL de LiF: Mg, Cu, P+Ptfe a rayos X de 24, 42 y 100 KeV

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez M, P.R.; Tovar M, V.M. [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico); Azorin N, J. [UAM-I, 09340 Mexico D.F. (Mexico); Furetta, C. [Universita degli Studi di Roma ' La Sapienza' , Piazzale Aldo Moro 2, 00185 Roma (Italy); Quiroz C, M.C. [Facultad de Medicina, UAEM, 50180 Toluca, Estado de Mexico (Mexico)

    2005-07-01

    In this work the obtained results of the irradiation of thermoluminescent dosemeters (Tl) of LiF: Mg,Cu,P + Ptfe with X rays for the effective radiation energy of 24, 42 and 100 keV, in an interval of Kerma in air in the sinus of the air between 0.05 and 1.0 Gy are presented. The rate of Kerma in air was determined with an ionization chamber PTW-1152, gauged by the Laboratoire Central des Industries Electriques (LCIE). As reference commercial TLD-100 dosemeters was used. The results showed that the studied Tl dosemeters presented a lineal response in the interval of mentioned Kerma. On the other hand the estimated Kerma with the Tl dosemeter in the calibration curves for X rays, were similar to the one measured with the previously gauged ionization chamber. The Tl of LiF: Mg, Cu, P + Ptfe, developed in the ININ, are highly reliable for X-ray dosimetry. (Author)

  16. Fabrication and characterization of perovskite-based CH{sub 3}NH{sub 3}Pb{sub 1-x}Ge{sub x}I{sub 3}, CH{sub 3}NH{sub 3}Pb{sub 1-x}Tl{sub x}I{sub 3} and CH{sub 3}NH{sub 3}Pb{sub 1-x}In{sub x}I{sub 3} photovoltaic devices

    Energy Technology Data Exchange (ETDEWEB)

    Ohishi, Yuya; Oku, Takeo, E-mail: oku@mat.usp.ac.jp; Suzuki, Atsushi [Department of Materials Science, The University of Shiga Prefecture 2500 Hassaka, Hikone, Shiga 522-8533 (Japan)

    2016-02-01

    Perovskite-type CH{sub 3}NH{sub 3}PbI{sub 3}-based photovoltaic devices were fabricated and characterized. Doping effects of thallium (Tl), indium (In), or germanium (Ge) element on the photovoltaic properties and surface structures of the perovskite phase were investigated. The open circuit voltage increased by Ge addition, and fill factors were improved by adding a small amount of Ge, Tl or In. In addition, the wavelength range of incident photon conversion efficiencies was expanded by the Tl addition.

  17. Comparative study of 201Tl reinjection mycoardial imaging and late imaging after reinjection for detecting myocardial viability

    International Nuclear Information System (INIS)

    Lin Jinghui; Chai Xiaofeng; Zhu Mei

    1997-01-01

    PURPOSE: To compare 201 Tl reinjection imaging with late imaging in detecting myocardial viability. METHODS: 62 patients with myocardial infarction underwent 201 Tl exercise, 3∼5 hours redistribution, 16∼35 minutes and 12∼19 hours post 201 Tl reinjection mycoardial tomography imaging. After imaging, percutaneous transluminal coronary angioplasty (PTCA) were performed in 15 patients, and then exercise-redistribution myocardial imaging were repeated. RESULTS: 62 patients had 126 segments of irreversible defects on stress-redistribution imaging, 48 segments showed radioactive filling at 16∼35 minutes post-reinjection. The detecting rate of myocardial viability was 38.1% (48/126). 51 segments presented redistribution on 12∼19 hours late imaging, the detecting rate of myocardial viability was 40.5% (51/126). There were no significant difference in the detecting rate between them (x 2 0.16, P>0.05). But in combination of both methods, there were 62 segments refilling, thereby detecting rate was enhanced to 49.2% (62/126). In 15 patients who had PTCA, out of 17 segments were discovered to be viable before PTCA. After PTCA 12 segments had an improved perfusion of 201 Tl, the positive predictive accuracy was 70.6%. Out of 11 segments were discovered to be infarcted, 9 segments had non-improved 201 Tl perfusion after PTCA, the negative predictive accuracy was 81.8%. CONCLUSION: There were no significant difference in the detecting rate of myocardial viability between 2 '0 1 Tl reinjection and late imaging. In combination of both methods the detecting rate can be enhanced

  18. Tsygankoite, Mn8Tl8Hg2(Sb21Pb2TlΣ24S48, a New Sulfosalt from the Vorontsovskoe Gold Deposit, Northern Urals, Russia

    Directory of Open Access Journals (Sweden)

    Anatoly V. Kasatkin

    2018-05-01

    Full Text Available Tsygankoite, ideally Mn8Tl8Hg2(Sb21Pb2TlΣ24S48, is a new sulfosalt discovered at the Vorontsovskoe gold deposit, Northern Urals, Russia. It occurs as lath-like elongated crystals up to 0.2 mm embedded in calcite–dolomite–clinochlore matrix. The associated minerals also include aktashite, alabandite, arsenopyrite, barite, cinnabar, fluorapatite, orpiment, pyrite, realgar, routhierite, sphalerite, tilasite, and titanite. The new mineral is non-fluorescent, black, and opaque with a metallic lustre and black streak. It is brittle with an uneven fracture and no obvious parting and cleavage. Its Vickers hardness (VHN10 is 144 kg/mm2 (range 131–167 kg/mm2 and its calculated density is 5.450 g cm. In reflected light, tsygankoite is white; between crossed polars it is dark grey to black. It is strongly anisotropic: rotation tints vary from light grey to dark grey to black. Pleochroism and internal reflections are not observed. The chemical composition of tsygankoite (wt %, electron-microprobe data is: Mn 6.29, Hg 5.42, Tl 26.05, Pb 5.84, As 3.39, Sb 30.89, S 21.87, total 99.75. The empirical formula, calculated on the basis of 90 atoms pfu, is: Mn8.06Tl8.00Hg1.90(Sb17.87As3.19Pb1.99Tl0.97Σ24.02S48.03. Tsygankoite is monoclinic, space group C2/m, a = 21.362(4 Å, b = 3.8579(10 Å, c = 27.135(4 Å, β = 106.944(14°, V = 2139.19(17 Å3 and Z = 1. The five strongest diffraction peaks from X-ray powder pattern (listed as (d,Å(I(hkl are: 3.587(100(112, 3.353(70(−114, 3.204(88(405, 2.841(72(−513, and 2.786(99(−514. The crystal structure of tsygankoite was refined from single-crystal X-ray diffraction data to R = 0.0607 and consists of an alternation of two thick layer-like arrays, one based on PbS-archetype and the second on SnS-archetype. Tsygankoite has been approved by the IMA-CNMNC under the number 2017-088. It is named for Mikhail V. Tsyganko, a mineral collector from Severouralsk, Northern Urals, Russia, who collected the samples where the

  19. Dosimetric characteristics of LKB:Cu,P solid TL detector

    International Nuclear Information System (INIS)

    Hashim, S.; Alajerami, Y.S.M.; Ghoshal, S.K.; Saleh, M.A.; Saripan, M.I.; Kadir, A.B.A.; Bradley, D.A.; Alzimami, K.

    2014-01-01

    The dosimetric characteristics of newly developed borate glass dosimeter modified with lithium and potassium carbonate (LKB) and co-doped with CuO and NH 4 H 2 PO 4 are reported. Broad peaks in the absence of any sharp peak confirms the amorphous nature of the prepared glass. A simple glow curve of Cu doped sample is observed with a single prominent peak (T m ) at 220 °C. The TL intensity response shows an enhancement of ∼100 times due to the addition of CuO (0.1 mol%) to LKB compound. A further enhancement of the intensity by a factor of 3 from the addition of 0.25 mol% NH 4 H 2 PO 4 as a co-dopant impurity is attributed to the creation of extra electron traps with consequent increase in energy transfer of radiation recombination centers. The TL yield performance of LKB:Cu,P with Z eff ≈8.92 is approximately seventeen times less sensitive compared to LiF:Mg,Ti (TLD-100). The proposed dosimeter shows good linearity up to 10 3 Gy, minimal fading and photon energy independence. These attractive features offered by our dosimeter is expected to pave the way towards dosimetric applications. - Highlights: • The NH 4 H 2 PO 4 impurities are cross linked with the CuO defect. • The addition of NH 4 H 2 PO 4 as a co-dopant improved the TL intensity by a factor of 3. • The proposed dosimeter shows good linearity up to 10 3 Gy. • Minimal fading and photon energy independence were observed

  20. Pulse-shape discrimination between electron and nuclear recoils in a NaI(Tl) crystal

    International Nuclear Information System (INIS)

    Lee, H.S.; Adhikari, G.; Adhikari, P.; Choi, S.; Hahn, I.S.

    2015-01-01

    We report on the response of a high light-output NaI(Tl) crystal to nuclear recoils induced by neutrons from an Am-Be source and compare the results with the response to electron recoils produced by Compton-scattered 662 keV γ-rays from a 137 Cs source. The measured pulse-shape discrimination (PSD) power of the NaI(Tl) crystal is found to be significantly improved because of the high light output of the NaI(Tl) detector. We quantify the PSD power with a quality factor and estimate the sensitivity to the interaction rate for weakly interacting massive particles (WIMPs) with nucleons, and the result is compared with the annual modulation amplitude observed by the DAMA/LIBRA experiment. The sensitivity to spin-independent WIMP-nucleon interactions based on 100 kg⋅year of data from NaI detectors is estimated with simulated experiments, using the standard halo model.