WorldWideScience

Sample records for relative standardization methods

  1. A standard curve based method for relative real time PCR data processing

    Directory of Open Access Journals (Sweden)

    Krause Andreas

    2005-03-01

    Full Text Available Abstract Background Currently real time PCR is the most precise method by which to measure gene expression. The method generates a large amount of raw numerical data and processing may notably influence final results. The data processing is based either on standard curves or on PCR efficiency assessment. At the moment, the PCR efficiency approach is preferred in relative PCR whilst the standard curve is often used for absolute PCR. However, there are no barriers to employ standard curves for relative PCR. This article provides an implementation of the standard curve method and discusses its advantages and limitations in relative real time PCR. Results We designed a procedure for data processing in relative real time PCR. The procedure completely avoids PCR efficiency assessment, minimizes operator involvement and provides a statistical assessment of intra-assay variation. The procedure includes the following steps. (I Noise is filtered from raw fluorescence readings by smoothing, baseline subtraction and amplitude normalization. (II The optimal threshold is selected automatically from regression parameters of the standard curve. (III Crossing points (CPs are derived directly from coordinates of points where the threshold line crosses fluorescence plots obtained after the noise filtering. (IV The means and their variances are calculated for CPs in PCR replicas. (V The final results are derived from the CPs' means. The CPs' variances are traced to results by the law of error propagation. A detailed description and analysis of this data processing is provided. The limitations associated with the use of parametric statistical methods and amplitude normalization are specifically analyzed and found fit to the routine laboratory practice. Different options are discussed for aggregation of data obtained from multiple reference genes. Conclusion A standard curve based procedure for PCR data processing has been compiled and validated. It illustrates that

  2. Determine equilibrium dissociation constant of drug-membrane receptor affinity using the cell membrane chromatography relative standard method.

    Science.gov (United States)

    Ma, Weina; Yang, Liu; Lv, Yanni; Fu, Jia; Zhang, Yanmin; He, Langchong

    2017-06-23

    The equilibrium dissociation constant (K D ) of drug-membrane receptor affinity is the basic parameter that reflects the strength of interaction. The cell membrane chromatography (CMC) method is an effective technique to study the characteristics of drug-membrane receptor affinity. In this study, the K D value of CMC relative standard method for the determination of drug-membrane receptor affinity was established to analyze the relative K D values of drugs binding to the membrane receptors (Epidermal growth factor receptor and angiotensin II receptor). The K D values obtained by the CMC relative standard method had a strong correlation with those obtained by the frontal analysis method. Additionally, the K D values obtained by CMC relative standard method correlated with pharmacological activity of the drug being evaluated. The CMC relative standard method is a convenient and effective method to evaluate drug-membrane receptor affinity. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Neutron activation analysis of reference materials by the k sub 0 standardization and relative methods

    Energy Technology Data Exchange (ETDEWEB)

    Freitas, M C; Martinho, E [LNETI/ICEN, Sacavem (Portugal)

    1989-04-15

    Instrumental neutron activation analysis with the k{sub o}-standardization method was applied to eight geological, environmental and biological reference materials, including leaves, blood, fish, sediments, soils and limestone. To a first approximation, the results were normally distributed around the certified values with a standard deviation of 10%. Results obtained by using the relative method based on well characterized multi-element standards for IAEA CRM Soil-7 are reported.

  4. The Standardization Method of Address Information for POIs from Internet Based on Positional Relation

    Directory of Open Access Journals (Sweden)

    WANG Yong

    2016-05-01

    Full Text Available As points of interest (POIon the internet, exists widely incomplete addresses and inconsistent literal expressions, a fast standardization processing method of network POIs address information based on spatial constraints was proposed. Based on the model of the extensible address expression, first of all, address information of POI was segmented and extracted. Address elements are updated by means of matching with the address tree layer by layer. Then, by defining four types of positional relations, corresponding set are selected from standard POI library as candidate for enrichment and amendment of non-standard address. At last, the fast standardized processing of POI address information was achieved with the help of backtracking address elements with minimum granularity. Experiments in this paper proved that the standardization processing of an address can be realized by means of this method with higher accuracy in order to build the address database.

  5. Evaluation methods for neutron cross section standards

    International Nuclear Information System (INIS)

    Bhat, M.R.

    1980-01-01

    Methods used to evaluate the neutron cross section standards are reviewed and their relative merits, assessed. These include phase-shift analysis, R-matrix fit, and a number of other methods by Poenitz, Bhat, Kon'shin and the Bayesian or generalized least-squares procedures. The problems involved in adopting these methods for future cross section standards evaluations are considered, and the prospects for their use, discussed. 115 references, 5 figures, 3 tables

  6. 29 CFR 1630.7 - Standards, criteria, or methods of administration.

    Science.gov (United States)

    2010-07-01

    ... Standards, criteria, or methods of administration. It is unlawful for a covered entity to use standards, criteria, or methods of administration, which are not job-related and consistent with business necessity... 29 Labor 4 2010-07-01 2010-07-01 false Standards, criteria, or methods of administration. 1630.7...

  7. Reactor Section standard analytical methods. Part 1

    Energy Technology Data Exchange (ETDEWEB)

    Sowden, D.

    1954-07-01

    the Standard Analytical Methods manual was prepared for the purpose of consolidating and standardizing all current analytical methods and procedures used in the Reactor Section for routine chemical analyses. All procedures are established in accordance with accepted practice and the general analytical methods specified by the Engineering Department. These procedures are specifically adapted to the requirements of the water treatment process and related operations. The methods included in this manual are organized alphabetically within the following five sections which correspond to the various phases of the analytical control program in which these analyses are to be used: water analyses, essential material analyses, cotton plug analyses boiler water analyses, and miscellaneous control analyses.

  8. Quantifying relative importance: Computing standardized effects in models with binary outcomes

    Science.gov (United States)

    Grace, James B.; Johnson, Darren; Lefcheck, Jonathan S.; Byrnes, Jarrett E.K.

    2018-01-01

    Scientists commonly ask questions about the relative importances of processes, and then turn to statistical models for answers. Standardized coefficients are typically used in such situations, with the goal being to compare effects on a common scale. Traditional approaches to obtaining standardized coefficients were developed with idealized Gaussian variables in mind. When responses are binary, complications arise that impact standardization methods. In this paper, we review, evaluate, and propose new methods for standardizing coefficients from models that contain binary outcomes. We first consider the interpretability of unstandardized coefficients and then examine two main approaches to standardization. One approach, which we refer to as the Latent-Theoretical or LT method, assumes that underlying binary observations there exists a latent, continuous propensity linearly related to the coefficients. A second approach, which we refer to as the Observed-Empirical or OE method, assumes responses are purely discrete and estimates error variance empirically via reference to a classical R2 estimator. We also evaluate the standard formula for calculating standardized coefficients based on standard deviations. Criticisms of this practice have been persistent, leading us to propose an alternative formula that is based on user-defined “relevant ranges”. Finally, we implement all of the above in an open-source package for the statistical software R.

  9. The density-salinity relation of standard seawater

    Science.gov (United States)

    Schmidt, Hannes; Seitz, Steffen; Hassel, Egon; Wolf, Henning

    2018-01-01

    The determination of salinity by means of electrical conductivity relies on stable salt proportions in the North Atlantic Ocean, because standard seawater, which is required for salinometer calibration, is produced from water of the North Atlantic. To verify the long-term stability of the standard seawater composition, it was proposed to perform measurements of the standard seawater density. Since the density is sensitive to all salt components, a density measurement can detect any change in the composition. A conversion of the density values to salinity can be performed by means of a density-salinity relation. To use such a relation with a target uncertainty in salinity comparable to that in salinity obtained from conductivity measurements, a density measurement with an uncertainty of 2 g m-3 is mandatory. We present a new density-salinity relation based on such accurate density measurements. The substitution measurement method used is described and density corrections for uniform isotopic and chemical compositions are reported. The comparison of densities calculated using the new relation with those calculated using the present reference equations of state TEOS-10 suggests that the density accuracy of TEOS-10 (as well as that of EOS-80) has been overestimated, as the accuracy of some of its underlying density measurements had been overestimated. The new density-salinity relation may be used to verify the stable composition of standard seawater by means of routine density measurements.

  10. Relation between the national handbook of recommended methods for water data acquisition and ASTM standards

    Science.gov (United States)

    Glysson, G. Douglas; Skinner, John V.

    1991-01-01

    In the late 1950's, intense demands for water and growing concerns about declines in the quality of water generated the need for more water-resources data. About thirty Federal agencies, hundreds of State, county and local agencies, and many private organizations had been collecting water data. However, because of differences in procedures and equipment, many of the data bases were incompatible. In 1964, as a step toward establishing more uniformity, the Bureau of the Budget (now the Office of Management and Budget, OMB) issued 'Circular A-67' which presented guidelines for collecting water data and also served as a catalyst for creating the Office of Water Data Coordination (OWDC) within the U.S. Geological Survey. This paper discusses past, present, and future aspects of the relation between methods in the National Handbook and standards published by ASTM (American Society for Testing and Materials) Committee D-19 on Water's Subcommittee D-19.07 on Sediment, Geomorphology, and Open Channel Flow. The discussion also covers historical aspects of standards - development work jointly conducted by OWDC and ASTM.

  11. Standard CMMIsm Appraisal Method for Process Improvement (SCAMPIsm), Version 1.1: Method Definition Document

    National Research Council Canada - National Science Library

    2001-01-01

    The Standard CMMI Appraisal Method for Process Improvement (SCAMPI(Service Mark)) is designed to provide benchmark quality ratings relative to Capability Maturity Model(registered) Integration (CMMI(Service Mark)) models...

  12. Standard setting: comparison of two methods.

    Science.gov (United States)

    George, Sanju; Haque, M Sayeed; Oyebode, Femi

    2006-09-14

    The outcome of assessments is determined by the standard-setting method used. There is a wide range of standard-setting methods and the two used most extensively in undergraduate medical education in the UK are the norm-reference and the criterion-reference methods. The aims of the study were to compare these two standard-setting methods for a multiple-choice question examination and to estimate the test-retest and inter-rater reliability of the modified Angoff method. The norm-reference method of standard-setting (mean minus 1 SD) was applied to the 'raw' scores of 78 4th-year medical students on a multiple-choice examination (MCQ). Two panels of raters also set the standard using the modified Angoff method for the same multiple-choice question paper on two occasions (6 months apart). We compared the pass/fail rates derived from the norm reference and the Angoff methods and also assessed the test-retest and inter-rater reliability of the modified Angoff method. The pass rate with the norm-reference method was 85% (66/78) and that by the Angoff method was 100% (78 out of 78). The percentage agreement between Angoff method and norm-reference was 78% (95% CI 69% - 87%). The modified Angoff method had an inter-rater reliability of 0.81-0.82 and a test-retest reliability of 0.59-0.74. There were significant differences in the outcomes of these two standard-setting methods, as shown by the difference in the proportion of candidates that passed and failed the assessment. The modified Angoff method was found to have good inter-rater reliability and moderate test-retest reliability.

  13. Standardization of Laser Methods and Techniques for Vibration Measurements and Calibrations

    International Nuclear Information System (INIS)

    Martens, Hans-Juergen von

    2010-01-01

    The realization and dissemination of the SI units of motion quantities (vibration and shock) have been based on laser interferometer methods specified in international documentary standards. New and refined laser methods and techniques developed by national metrology institutes and by leading manufacturers in the past two decades have been swiftly specified as standard methods for inclusion into in the series ISO 16063 of international documentary standards. A survey of ISO Standards for the calibration of vibration and shock transducers demonstrates the extended ranges and improved accuracy (measurement uncertainty) of laser methods and techniques for vibration and shock measurements and calibrations. The first standard for the calibration of laser vibrometers by laser interferometry or by a reference accelerometer calibrated by laser interferometry (ISO 16063-41) is on the stage of a Draft International Standard (DIS) and may be issued by the end of 2010. The standard methods with refined techniques proved to achieve wider measurement ranges and smaller measurement uncertainties than that specified in the ISO Standards. The applicability of different standardized interferometer methods to vibrations at high frequencies was recently demonstrated up to 347 kHz (acceleration amplitudes up to 350 km/s 2 ). The relative deviations between the amplitude measurement results of the different interferometer methods that were applied simultaneously, differed by less than 1% in all cases.

  14. Evaluation of the H-point standard additions method (HPSAM) and the generalized H-point standard additions method (GHPSAM) for the UV-analysis of two-component mixtures.

    Science.gov (United States)

    Hund, E; Massart, D L; Smeyers-Verbeke, J

    1999-10-01

    The H-point standard additions method (HPSAM) and two versions of the generalized H-point standard additions method (GHPSAM) are evaluated for the UV-analysis of two-component mixtures. Synthetic mixtures of anhydrous caffeine and phenazone as well as of atovaquone and proguanil hydrochloride were used. Furthermore, the method was applied to pharmaceutical formulations that contain these compounds as active drug substances. This paper shows both the difficulties that are related to the methods and the conditions by which acceptable results can be obtained.

  15. Standard setting: Comparison of two methods

    Directory of Open Access Journals (Sweden)

    Oyebode Femi

    2006-09-01

    Full Text Available Abstract Background The outcome of assessments is determined by the standard-setting method used. There is a wide range of standard – setting methods and the two used most extensively in undergraduate medical education in the UK are the norm-reference and the criterion-reference methods. The aims of the study were to compare these two standard-setting methods for a multiple-choice question examination and to estimate the test-retest and inter-rater reliability of the modified Angoff method. Methods The norm – reference method of standard -setting (mean minus 1 SD was applied to the 'raw' scores of 78 4th-year medical students on a multiple-choice examination (MCQ. Two panels of raters also set the standard using the modified Angoff method for the same multiple-choice question paper on two occasions (6 months apart. We compared the pass/fail rates derived from the norm reference and the Angoff methods and also assessed the test-retest and inter-rater reliability of the modified Angoff method. Results The pass rate with the norm-reference method was 85% (66/78 and that by the Angoff method was 100% (78 out of 78. The percentage agreement between Angoff method and norm-reference was 78% (95% CI 69% – 87%. The modified Angoff method had an inter-rater reliability of 0.81 – 0.82 and a test-retest reliability of 0.59–0.74. Conclusion There were significant differences in the outcomes of these two standard-setting methods, as shown by the difference in the proportion of candidates that passed and failed the assessment. The modified Angoff method was found to have good inter-rater reliability and moderate test-retest reliability.

  16. Reducing matrix effect error in EDXRF: Comparative study of using standard and standard less methods for stainless steel samples

    International Nuclear Information System (INIS)

    Meor Yusoff Meor Sulaiman; Masliana Muhammad; Wilfred, P.

    2013-01-01

    Even though EDXRF analysis has major advantages in the analysis of stainless steel samples such as simultaneous determination of the minor elements, analysis can be done without sample preparation and non-destructive analysis, the matrix issue arise from the inter element interaction can make the the final quantitative result to be in accurate. The paper relates a comparative quantitative analysis using standard and standard less methods in the determination of these elements. Standard method was done by plotting regression calibration graphs of the interested elements using BCS certified stainless steel standards. Different calibration plots were developed based on the available certified standards and these stainless steel grades include low alloy steel, austenitic, ferritic and high speed. The standard less method on the other hand uses a mathematical modelling with matrix effect correction derived from Lucas-Tooth and Price model. Further improvement on the accuracy of the standard less method was done by inclusion of pure elements into the development of the model. Discrepancy tests were then carried out for these quantitative methods on different certified samples and the results show that the high speed method is most reliable for determining of Ni and the standard less method for Mn. (Author)

  17. IEEE Std 382-1980: IEEE standard for qualification of safety-related valve actuators

    International Nuclear Information System (INIS)

    Anon.

    1992-01-01

    This standard describes the qualification of all types of power-driven valve actuators, including damper actuators, for safety-related functions in nuclear power generating stations. This standard may also be used to separately qualify actuator components. This standard establishes the minimum requirements for, and guidance regarding, the methods and procedures for qualification of all safety-related functions of power-driven valve actuators

  18. Photon and proton activation analysis of iron and steel standards using the internal standard method coupled with the standard addition method

    International Nuclear Information System (INIS)

    Masumoto, K.; Hara, M.; Hasegawa, D.; Iino, E.; Yagi, M.

    1997-01-01

    The internal standard method coupled with the standard addition method has been applied to photon activation analysis and proton activation analysis of minor elements and trace impurities in various types of iron and steel samples issued by the Iron and Steel Institute of Japan (ISIJ). Samples and standard addition samples were once dissolved to mix homogeneously, an internal standard and elements to be determined and solidified as a silica-gel to make a similar matrix composition and geometry. Cerium and yttrium were used as an internal standard in photon and proton activation, respectively. In photon activation, 20 MeV electron beam was used for bremsstrahlung irradiation to reduce matrix activity and nuclear interference reactions, and the results were compared with those of 30 MeV irradiation. In proton activation, iron was removed by the MIBK extraction method after dissolving samples to reduce the radioactivity of 56 Co from iron via 56 Fe(p, n) 56 Co reaction. The results of proton and photon activation analysis were in good agreement with the standard values of ISIJ. (author)

  19. Standard test method for isotopic analysis of uranium hexafluoride by double standard single-collector gas mass spectrometer method

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This is a quantitative test method applicable to determining the mass percent of uranium isotopes in uranium hexafluoride (UF6) samples with 235U concentrations between 0.1 and 5.0 mass %. 1.2 This test method may be applicable for the entire range of 235U concentrations for which adequate standards are available. 1.3 This test method is for analysis by a gas magnetic sector mass spectrometer with a single collector using interpolation to determine the isotopic concentration of an unknown sample between two characterized UF6 standards. 1.4 This test method is to replace the existing test method currently published in Test Methods C761 and is used in the nuclear fuel cycle for UF6 isotopic analyses. 1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appro...

  20. Inter-examiner reliability of a standardized Ultra-sonographic method for classification of changes related to supraspinatus tendinopathy – a pilot study

    DEFF Research Database (Denmark)

    Larsen, Camilla Marie; Ingwersen, Kim Gordon; Hjarnbæk, John

    2015-01-01

    Inter-examiner reliability of a standardized Ultra-sonographic method for classification of changes related to supraspinatus tendinopathy – a pilot study Ingwersen KG1, 2, Hjarbaek J3, Eshøj H1, Larsen CM1, 4, Vobbe J5, Juul-Kristensen B1, 6 1Institute of Sports Science and Clinical Biomechanics......, University of Southern Denmark, Odense, Denmark. 2Physiotherapy Department, Hospital Lillebaelt, Vejle Hospital, Vejle, Denmark 3Department of Radiology, Musculoskeletal section, Odense University Hospital, Odense, Denmark 4Health Sciences Research Centre, University College Lillebaelt, Odense Denmark 5...... athletes. For optimizing rehabilitation to the different stages of tendinopathy (1) ultra-sonography (US) may be used. Reliability of such method for RT is lacking. Aims. To develop and test inter-examiner reliability of US for classifying RT. Materials and Methods. A three-phased standardized protocol...

  1. Standard test methods for rockwell hardness of metallic materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 These test methods cover the determination of the Rockwell hardness and the Rockwell superficial hardness of metallic materials by the Rockwell indentation hardness principle. This standard provides the requirements for Rockwell hardness machines and the procedures for performing Rockwell hardness tests. 1.2 This standard includes additional requirements in annexes: Verification of Rockwell Hardness Testing Machines Annex A1 Rockwell Hardness Standardizing Machines Annex A2 Standardization of Rockwell Indenters Annex A3 Standardization of Rockwell Hardness Test Blocks Annex A4 Guidelines for Determining the Minimum Thickness of a Test Piece Annex A5 Hardness Value Corrections When Testing on Convex Cylindrical Surfaces Annex A6 1.3 This standard includes nonmandatory information in appendixes which relates to the Rockwell hardness test. List of ASTM Standards Giving Hardness Values Corresponding to Tensile Strength Appendix X1 Examples of Procedures for Determining Rockwell Hardness Uncertainty Appendix X...

  2. Standard test methods for rockwell hardness of metallic materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2011-01-01

    1.1 These test methods cover the determination of the Rockwell hardness and the Rockwell superficial hardness of metallic materials by the Rockwell indentation hardness principle. This standard provides the requirements for Rockwell hardness machines and the procedures for performing Rockwell hardness tests. 1.2 This standard includes additional requirements in annexes: Verification of Rockwell Hardness Testing Machines Annex A1 Rockwell Hardness Standardizing Machines Annex A2 Standardization of Rockwell Indenters Annex A3 Standardization of Rockwell Hardness Test Blocks Annex A4 Guidelines for Determining the Minimum Thickness of a Test Piece Annex A5 Hardness Value Corrections When Testing on Convex Cylindrical Surfaces Annex A6 1.3 This standard includes nonmandatory information in appendixes which relates to the Rockwell hardness test. List of ASTM Standards Giving Hardness Values Corresponding to Tensile Strength Appendix X1 Examples of Procedures for Determining Rockwell Hardness Uncertainty Appendix X...

  3. Comparison of uncertainties related to standardization of urine samples with volume and creatinine concentration

    DEFF Research Database (Denmark)

    Garde, Anne Helene; Hansen, Ase Marie; Kristiansen, Jesper

    2004-01-01

    When measuring biomarkers in urine, volume (and time) or concentration of creatinine are both accepted methods of standardization for diuresis. Both types of standardization contribute uncertainty to the final result. The aim of the present paper was to compare the uncertainty introduced when usi...... increase in convenience for the participants, when collecting small volumes rather than complete 24 h samples....... the two types of standardization on 24 h samples from healthy individuals. Estimates of uncertainties were based on results from the literature supplemented with data from our own studies. Only the difference in uncertainty related to the two standardization methods was evaluated. It was found...... that the uncertainty associated with creatinine standardization (19-35%) was higher than the uncertainty related to volume standardization (up to 10%, when not correcting for deviations from 24 h) for 24 h urine samples. However, volume standardization introduced an average bias of 4% due to missed volumes...

  4. An external standard method for quantification of human cytomegalovirus by PCR

    International Nuclear Information System (INIS)

    Rongsen, Shen; Liren, Ma; Fengqi, Zhou; Qingliang, Luo

    1997-01-01

    An external standard method for PCR quantification of HCMV was reported. [α- 32 P]dATP was used as a tracer. 32 P-labelled specific amplification product was separated by agarose gel electrophoresis. A gel piece containing the specific product band was excised and counted in a plastic scintillation counter. Distribution of [α- 32 P]dATP in the electrophoretic gel plate and effect of separation between the 32 P-labelled specific product and free [α- 32 P]dATP were observed. A standard curve for quantification of HCMV by PCR was established and detective results of quality control templets were presented. The external standard method and the electrophoresis separation effect were appraised. The results showed that the method could be used for relative quantification of HCMV. (author)

  5. Analysis and Comparison of Thickness and Bending Measurements from Fabric Touch Tester (FTT and Standard Methods

    Directory of Open Access Journals (Sweden)

    Musa Atiyyah Binti Haji

    2018-03-01

    Full Text Available Fabric Touch Tester (FTT is a relatively new device from SDL Atlas to determine touch properties of fabrics. It simultaneously measures 13 touch-related fabric physical properties in four modules that include bending and thickness measurements. This study aims to comparatively analyze the thickness and bending measurements made by the FTT and the common standard methods used in the textile industry. The results obtained with the FTT for 11 different fabrics were compared with that of standard methods. Despite the different measurement principle, a good correlation was found between the two methods used for the assessment of thickness and bending. As FTT is a new tool for textile comfort measurement and no standard yet exists, these findings are essential to determine the reliability of the measurements and how they relate to the well-established standard methods.

  6. Standard Test Method for Water Absorption of Core Materials for Structural Sandwich Constructions

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2001-01-01

    1.1 This test method covers the determination of the relative amount of water absorption by various types of structural core materials when immersed or in a high relative humidity environment. This test method is intended to apply to only structural core materials; honeycomb, foam, and balsa wood. 1.2 The values stated in SI units are to be regarded as the standard. The inch-pound units given may be approximate. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  7. Standard Test Method for Measuring Optical Angular Deviation of Transparent Parts

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1996-01-01

    1.1 This test method covers measuring the angular deviation of a light ray imposed by transparent parts such as aircraft windscreens and canopies. The results are uncontaminated by the effects of lateral displacement, and the procedure may be performed in a relatively short optical path length. This is not intended as a referee standard. It is one convenient method for measuring angular deviations through transparent windows. 1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  8. Standards for Educational Public Relations and Communications Professionals.

    Science.gov (United States)

    Chappelow, Marsha A.

    2003-01-01

    Describes National School Public Relations Association standards for school public relations and communications professionals and program. Includes reactions and comments about new Association standards from seven superintendents and four school public-relations professionals. (PKP)

  9. IMPROVING MANAGEMENT ACCOUNTING AND COST CALCULATION IN DAIRY INDUSTRY USING STANDARD COST METHOD

    Directory of Open Access Journals (Sweden)

    Bogdănoiu Cristiana-Luminiţa

    2013-04-01

    Full Text Available This paper aims to discuss issues related to the improvement of management accounting in the dairy industry by implementing standard cost method. The methods used today do not provide informational satisfaction to managers in order to conduct effectively production activities, which is why we attempted the standard cost method, it responding to the managers needs to obtain the efficiency of production, and all economic entities. The method allows an operative control of how they consume manpower and material resources by pursuing distinct, permanent and complete deviations during the activity and not at the end of the reporting period. Successful implementation of the standard method depends on the accuracy by which standards are developed and promotes consistently anticipated calculation of production costs as well as determination, tracking and controlling deviations from them, leads to increased practical value of accounting information and business improvement.

  10. Standard Test Method for Electronic Measurement for Hydrogen Embrittlement From Cadmium-Electroplating Processes

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1996-01-01

    1.1 This test method covers an electronic hydrogen detection instrument procedure for measurement of plating permeability to hydrogen. This method measures a variable related to hydrogen absorbed by steel during plating and to the hydrogen permeability of the plate during post plate baking. A specific application of this method is controlling cadmium-plating processes in which the plate porosity relative to hydrogen is critical, such as cadmium on high-strength steel. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific hazard statement, see Section 8. 1.2 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.

  11. An ecological method to understand agricultural standardization in peach orchard ecosystems.

    Science.gov (United States)

    Wan, Nian-Feng; Zhang, Ming-Yi; Jiang, Jie-Xian; Ji, Xiang-Yun; Hao-Zhang

    2016-02-22

    While the worldwide standardization of agricultural production has been advocated and recommended, relatively little research has focused on the ecological significance of such a shift. The ecological concerns stemming from the standardization of agricultural production may require new methodology. In this study, we concentrated on how ecological two-sidedness and ecological processes affect the standardization of agricultural production which was divided into three phrases (pre-, mid- and post-production), considering both the positive and negative effects of agricultural processes. We constructed evaluation indicator systems for the pre-, mid- and post-production phases and here we presented a Standardization of Green Production Index (SGPI) based on the Full Permutation Polygon Synthetic Indicator (FPPSI) method which we used to assess the superiority of three methods of standardized production for peaches. The values of SGPI for pre-, mid- and post-production were 0.121 (Level IV, "Excellent" standard), 0.379 (Level III, "Good" standard), and 0.769 × 10(-2) (Level IV, "Excellent" standard), respectively. Here we aimed to explore the integrated application of ecological two-sidedness and ecological process in agricultural production. Our results are of use to decision-makers and ecologists focusing on eco-agriculture and those farmers who hope to implement standardized agricultural production practices.

  12. Standard methods for sampling North American freshwater fishes

    Science.gov (United States)

    Bonar, Scott A.; Hubert, Wayne A.; Willis, David W.

    2009-01-01

    This important reference book provides standard sampling methods recommended by the American Fisheries Society for assessing and monitoring freshwater fish populations in North America. Methods apply to ponds, reservoirs, natural lakes, and streams and rivers containing cold and warmwater fishes. Range-wide and eco-regional averages for indices of abundance, population structure, and condition for individual species are supplied to facilitate comparisons of standard data among populations. Provides information on converting nonstandard to standard data, statistical and database procedures for analyzing and storing standard data, and methods to prevent transfer of invasive species while sampling.

  13. Choose of standard materials in the method of β-testing new materials' mass thickness

    International Nuclear Information System (INIS)

    Chen Zhong

    2007-01-01

    To make sure of the standard mass thickness in beta radials testing mass thickness, this paper calculate using M. C. method and get the result of the relations between the beta radials' transmission rate of different energies and mass thickness in different materials. This result prove that in method of beta test mass thickness choosing materials whose elements are close as standard materials are viable. (authors)

  14. [Precautions of physical performance requirements and test methods during product standard drafting process of medical devices].

    Science.gov (United States)

    Song, Jin-Zi; Wan, Min; Xu, Hui; Yao, Xiu-Jun; Zhang, Bo; Wang, Jin-Hong

    2009-09-01

    The major idea of this article is to discuss standardization and normalization for the product standard of medical devices. Analyze the problem related to the physical performance requirements and test methods during product standard drafting process and make corresponding suggestions.

  15. Towards standard testbeds for numerical relativity

    International Nuclear Information System (INIS)

    Alcubierre, Miguel; Allen, Gabrielle; Bona, Carles; Fiske, David; Goodale, Tom; Guzman, F Siddhartha; Hawke, Ian; Hawley, Scott H; Husa, Sascha; Koppitz, Michael; Lechner, Christiane; Pollney, Denis; Rideout, David; Salgado, Marcelo; Schnetter, Erik; Seidel, Edward; Shinkai, Hisa-aki; Shoemaker, Deirdre; Szilagyi, Bela; Takahashi, Ryoji; Winicour, Jeff

    2004-01-01

    In recent years, many different numerical evolution schemes for Einstein's equations have been proposed to address stability and accuracy problems that have plagued the numerical relativity community for decades. Some of these approaches have been tested on different spacetimes, and conclusions have been drawn based on these tests. However, differences in results originate from many sources, including not only formulations of the equations, but also gauges, boundary conditions, numerical methods and so on. We propose to build up a suite of standardized testbeds for comparing approaches to the numerical evolution of Einstein's equations that are designed to both probe their strengths and weaknesses and to separate out different effects, and their causes, seen in the results. We discuss general design principles of suitable testbeds, and we present an initial round of simple tests with periodic boundary conditions. This is a pivotal first step towards building a suite of testbeds to serve the numerical relativists and researchers from related fields who wish to assess the capabilities of numerical relativity codes. We present some examples of how these tests can be quite effective in revealing various limitations of different approaches, and illustrating their differences. The tests are presently limited to vacuum spacetimes, can be run on modest computational resources and can be used with many different approaches used in the relativity community

  16. Towards standard testbeds for numerical relativity

    Energy Technology Data Exchange (ETDEWEB)

    Alcubierre, Miguel [Inst. de Ciencias Nucleares, Univ. Nacional Autonoma de Mexico, Apartado Postal 70-543, Mexico Distrito Federal 04510 (Mexico); Allen, Gabrielle; Goodale, Tom; Guzman, F Siddhartha; Hawke, Ian; Husa, Sascha; Koppitz, Michael; Lechner, Christiane; Pollney, Denis; Rideout, David [Max-Planck-Inst. fuer Gravitationsphysik, Albert-Einstein-Institut, 14476 Golm (Germany); Bona, Carles [Departament de Fisica, Universitat de les Illes Balears, Ctra de Valldemossa km 7.5, 07122 Palma de Mallorca (Spain); Fiske, David [Dept. of Physics, Univ. of Maryland, College Park, MD 20742-4111 (United States); Hawley, Scott H [Center for Relativity, Univ. of Texas at Austin, Austin, Texas 78712 (United States); Salgado, Marcelo [Inst. de Ciencias Nucleares, Univ. Nacional Autonoma de Mexico, Apartado Postal 70-543, Mexico Distrito Federal 04510 (Mexico); Schnetter, Erik [Inst. fuer Astronomie und Astrophysik, Universitaet Tuebingen, 72076 Tuebingen (Germany); Seidel, Edward [Max-Planck-Inst. fuer Gravitationsphysik, Albert-Einstein-Inst., 14476 Golm (Germany); Shinkai, Hisa-aki [Computational Science Div., Inst. of Physical and Chemical Research (RIKEN), Hirosawa 2-1, Wako, Saitama 351-0198 (Japan); Shoemaker, Deirdre [Center for Radiophysics and Space Research, Cornell Univ., Ithaca, NY 14853 (United States); Szilagyi, Bela [Dept. of Physics and Astronomy, Univ. of Pittsburgh, Pittsburgh, PA 15260 (United States); Takahashi, Ryoji [Theoretical Astrophysics Center, Juliane Maries Vej 30, 2100 Copenhagen, (Denmark); Winicour, Jeff [Max-Planck-Inst. fuer Gravitationsphysik, Albert-Einstein-Institut, 14476 Golm (Germany)

    2004-01-21

    In recent years, many different numerical evolution schemes for Einstein's equations have been proposed to address stability and accuracy problems that have plagued the numerical relativity community for decades. Some of these approaches have been tested on different spacetimes, and conclusions have been drawn based on these tests. However, differences in results originate from many sources, including not only formulations of the equations, but also gauges, boundary conditions, numerical methods and so on. We propose to build up a suite of standardized testbeds for comparing approaches to the numerical evolution of Einstein's equations that are designed to both probe their strengths and weaknesses and to separate out different effects, and their causes, seen in the results. We discuss general design principles of suitable testbeds, and we present an initial round of simple tests with periodic boundary conditions. This is a pivotal first step towards building a suite of testbeds to serve the numerical relativists and researchers from related fields who wish to assess the capabilities of numerical relativity codes. We present some examples of how these tests can be quite effective in revealing various limitations of different approaches, and illustrating their differences. The tests are presently limited to vacuum spacetimes, can be run on modest computational resources and can be used with many different approaches used in the relativity community.

  17. Standard Test Method for Sandwich Corrosion Test

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This test method defines the procedure for evaluating the corrosivity of aircraft maintenance chemicals, when present between faying surfaces (sandwich) of aluminum alloys commonly used for aircraft structures. This test method is intended to be used in the qualification and approval of compounds employed in aircraft maintenance operations. 1.2 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information. 1.3 This standard may involve hazardous materials, operations, and equipment. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific hazard statements appear in Section 9.

  18. Toward a standard method for determination of waterborne radon

    International Nuclear Information System (INIS)

    Vitz, E.

    1990-01-01

    When the USEPA specifies the maximum contaminant level (MCL) for any contaminant, a standard method for analysis must be simultaneously stipulated. Promulgation of the proposed MCL and standard method for radon in drinking water is expected by early next year, but a six-month comment period and revision will precede final enactment. The standard method for radon in drinking water will probably specify that either the Lucas cell technique or liquid scintillation spectrometry be used. This paper reports results which support a standard method with the following features: samples should be collected by an explicitly stated technique to control degassing, in glass vials with or without scintillation cocktail, and possibly in duplicate; samples should be measured by liquid scintillation spectroscopy in a specified energy window', in a glass vial with particular types of cocktails; radium standards should be prepared with controlled quench levels and specified levels of carriers, but radium-free controls prepared by a specified method should be used in interlaboratory comparison studies

  19. Standard test methods for characterizing duplex grain sizes

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2002-01-01

    1.1 These test methods provide simple guidelines for deciding whether a duplex grain size exists. The test methods separate duplex grain sizes into one of two distinct classes, then into specific types within those classes, and provide systems for grain size characterization of each type. 1.2 Units—The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This standard may involve hazardous materials, operations, and equipment. This standard does not purport to address all of the safety concerns associated with its use. It is the responsibility of the user of this standard to consult appropriate safety and health practices and determine the applicability of regulatory limitations prior to its use.

  20. Standardization of 57Co using different methods of LNMRI

    International Nuclear Information System (INIS)

    Rezende, E.A.; Lopes, R.T.; Silva, C.J. da; Poledna, R.; Silva, R.L. da; Tauhata, L.

    2015-01-01

    The activity of a 57 Co solution was determined using four LNMRI different measurement methods. The solution was standardized by live-timed anti-coincidence method and sum-peak method. The efficiency curve and standard-sample comparison methods were also used in this comparison. The results and their measurement uncertainties demonstrating the equivalence of these methods. As an additional contribution, the gamma emission probabilities of 57 Co were also determined. (author)

  1. Standard method for economic analyses of inertial confinement fusion power plants

    International Nuclear Information System (INIS)

    Meier, W.R.

    1986-01-01

    A standard method for calculating the total capital cost and the cost of electricity for a typical inertial confinement fusion electric power plant has been developed. A standard code of accounts at the two-digit level is given for the factors making up the total capital cost of the power plant. Equations are given for calculating the indirect capital costs, the project contingency, and the time-related costs. Expressions for calculating the fixed charge rate, which is necessary to determine the cost of electricity, are also described. Default parameters are given to define a reference case for comparative economic analyses

  2. Determination of free acid by standard addition method in potassium thiocyanate

    International Nuclear Information System (INIS)

    Baumann, E.W.

    1982-06-01

    The free acid content of solutions containing hydrolyzable ions has been determined potentiometrically by a standard addition method. Two increments of acid are added to the sample in 1M potassium thiocyanate solution. The sample concentration is calculated by solution of three simultaneous Nernst equations. The method has been demonstrated for solutions containing Al 3+ , Cr 3+ , Fe 3+ , Hg 2+ , Ni 2+ , Th 4+ , or UO 2 2+ with a metal-to-acid ratio of < 2.5. The method is suitable for determination of 10 μmoles acid in 10 mL total volume. The accuracy can be judged from the agreement of the Nernst slopes found in the presence and absence of hydrolyzable ions. The relative standard deviation is < 2.5%. The report includes a survey of experiments with thermometric, pH, and Gran plot titrations in a variety of complexants, from which the method was evolved. Also included is a literature survey of sixty references, a discussion of the basic measurements, and a complete analytical procedure

  3. Standard test method for galling resistance of material couples

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 This test method covers a laboratory test that ranks the galling resistance of material couples using a quantitative measure. Bare metals, alloys, nonmetallic materials, coatings, and surface modified materials may be evaluated by this test method. 1.2 This test method is not designed for evaluating the galling resistance of material couples sliding under lubricated conditions, because galling usually will not occur under lubricated sliding conditions using this test method. 1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  4. Comparisons of ANSI standards cited in the NRC standard review plan, NUREG-0800 and related documents

    International Nuclear Information System (INIS)

    Ankrum, A.R.; Bohlander, K.L.; Gilbert, E.R.; Pawlowski, R.A.; Spiesman, J.B.

    1995-11-01

    This report provides the results of comparisons of the cited and latest versions of ANSI standards cited in the NRC Standard Review Plan for the Review of Safety Analysis Reports for Nuclear Power Plants (NUREG 0800) and related documents. The comparisons were performed by Battelle Pacific Northwest Laboratories in support of the NRC's Standard Review Plan Update and Development Program. Significant changes to the standards, from the cited version to the latest version, are described and discussed in a tabular format for each standard. Recommendations for updating each citation in the Standard Review Plan are presented. Technical considerations and suggested changes are included for related regulatory documents (i.e., Regulatory Guides and the Code of Federal Regulations) citing the standard. The results and recommendations presented in this document have not been subjected to NRC staff review

  5. Comparisons of ASTM standards cited in the NRC standard review plan, NUREG-0800 and related documents

    International Nuclear Information System (INIS)

    Ankrum, A.R.; Bohlander, K.L.; Gilbert, E.R.; Pawlowski, R.A.; Spiesman, J.B.

    1995-10-01

    This report provides the results of comparisons of the cited and latest versions of ASTM standards cited in the NRC Standard Review Plan for the Review of Safety Analysis Reports for Nuclear Power Plants (NUREG 0800) and related documents. The comparisons were performed by Battelle Pacific Northwest Laboratories in support of the NRC's Standard Review Plan Update and Development Program. Significant changes to the standards, from the cited version to the latest version, are described and discussed in a tabular format for each standard. Recommendations for updating each citation in the Standard Review Plan are presented. Technical considerations and suggested changes are included for related regulatory documents (i.e., Regulatory Guides and the Code of Federal Regulations) citing the standard. The results and recommendations presented in this document have not been subjected to NRC staff review

  6. An isotope-dilution standard GC/MS/MS method for steroid hormones in water

    Science.gov (United States)

    Foreman, William T.; Gray, James L.; ReVello, Rhiannon C.; Lindley, Chris E.; Losche, Scott A.

    2013-01-01

    An isotope-dilution quantification method was developed for 20 natural and synthetic steroid hormones and additional compounds in filtered and unfiltered water. Deuterium- or carbon-13-labeled isotope-dilution standards (IDSs) are added to the water sample, which is passed through an octadecylsilyl solid-phase extraction (SPE) disk. Following extract cleanup using Florisil SPE, method compounds are converted to trimethylsilyl derivatives and analyzed by gas chromatography with tandem mass spectrometry. Validation matrices included reagent water, wastewater-affected surface water, and primary (no biological treatment) and secondary wastewater effluent. Overall method recovery for all analytes in these matrices averaged 100%; with overall relative standard deviation of 28%. Mean recoveries of the 20 individual analytes for spiked reagent-water samples prepared along with field samples analyzed in 2009–2010 ranged from 84–104%, with relative standard deviations of 6–36%. Detection levels estimated using ASTM International’s D6091–07 procedure range from 0.4 to 4 ng/L for 17 analytes. Higher censoring levels of 100 ng/L for bisphenol A and 200 ng/L for cholesterol and 3-beta-coprostanol are used to prevent bias and false positives associated with the presence of these analytes in blanks. Absolute method recoveries of the IDSs provide sample-specific performance information and guide data reporting. Careful selection of labeled compounds for use as IDSs is important because both inexact IDS-analyte matches and deuterium label loss affect an IDS’s ability to emulate analyte performance. Six IDS compounds initially tested and applied in this method exhibited deuterium loss and are not used in the final method.

  7. Standard test method for damage to contacting solid surfaces under fretting conditions

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This test method covers the studying or ranking the susceptibility of candidate materials to fretting corrosion or fretting wear for the purposes of material selection for applications where fretting corrosion or fretting wear can limit serviceability. 1.2 This test method uses a tribological bench test apparatus with a mechanism or device that will produce the necessary relative motion between a contacting hemispherical rider and a flat counterface. The rider is pressed against the flat counterface with a loading mass. The test method is intended for use in room temperature air, but future editions could include fretting in the presence of lubricants or other environments. 1.3 The purpose of this test method is to rub two solid surfaces together under controlled fretting conditions and to quantify the damage to both surfaces in units of volume loss for the test method. 1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.5...

  8. Standard Test Method for Oxyacetylene Ablation Testing of Thermal Insulation Materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 This test method covers the screening of ablative materials to determine the relative thermal insulation effectiveness when tested as a flat panel in an environment of a steady flow of hot gas provided by an oxyacetylene burner. 1.2 This test method should be used to measure and describe the properties of materials, products, or assemblies in response to heat and flame under controlled laboratory conditions and should not be used to describe or appraise the fire hazard of materials, products, or assemblies under actual fire conditions. However, results of this test method may be used as elements of a fire risk assessment which takes into account all of the factors which are pertinent to an assessment of the fire hazard of a particular end use. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limi...

  9. A method to implement fine-grained access control for personal health records through standard relational database queries.

    Science.gov (United States)

    Sujansky, Walter V; Faus, Sam A; Stone, Ethan; Brennan, Patricia Flatley

    2010-10-01

    Online personal health records (PHRs) enable patients to access, manage, and share certain of their own health information electronically. This capability creates the need for precise access-controls mechanisms that restrict the sharing of data to that intended by the patient. The authors describe the design and implementation of an access-control mechanism for PHR repositories that is modeled on the eXtensible Access Control Markup Language (XACML) standard, but intended to reduce the cognitive and computational complexity of XACML. The authors implemented the mechanism entirely in a relational database system using ANSI-standard SQL statements. Based on a set of access-control rules encoded as relational table rows, the mechanism determines via a single SQL query whether a user who accesses patient data from a specific application is authorized to perform a requested operation on a specified data object. Testing of this query on a moderately large database has demonstrated execution times consistently below 100ms. The authors include the details of the implementation, including algorithms, examples, and a test database as Supplementary materials. Copyright © 2010 Elsevier Inc. All rights reserved.

  10. Standard methods for sampling freshwater fishes: Opportunities for international collaboration

    Science.gov (United States)

    Bonar, Scott A.; Mercado-Silva, Norman; Hubert, Wayne A.; Beard, Douglas; Dave, Göran; Kubečka, Jan; Graeb, Brian D. S.; Lester, Nigel P.; Porath, Mark T.; Winfield, Ian J.

    2017-01-01

    With publication of Standard Methods for Sampling North American Freshwater Fishes in 2009, the American Fisheries Society (AFS) recommended standard procedures for North America. To explore interest in standardizing at intercontinental scales, a symposium attended by international specialists in freshwater fish sampling was convened at the 145th Annual AFS Meeting in Portland, Oregon, in August 2015. Participants represented all continents except Australia and Antarctica and were employed by state and federal agencies, universities, nongovernmental organizations, and consulting businesses. Currently, standardization is practiced mostly in North America and Europe. Participants described how standardization has been important for management of long-term data sets, promoting fundamental scientific understanding, and assessing efficacy of large spatial scale management strategies. Academics indicated that standardization has been useful in fisheries education because time previously used to teach how sampling methods are developed is now more devoted to diagnosis and treatment of problem fish communities. Researchers reported that standardization allowed increased sample size for method validation and calibration. Group consensus was to retain continental standards where they currently exist but to further explore international and intercontinental standardization, specifically identifying where synergies and bridges exist, and identify means to collaborate with scientists where standardization is limited but interest and need occur.

  11. Determination of trace elements in standard reference materials by the ko-standardization method

    International Nuclear Information System (INIS)

    Smodis, B.; Jacimovic, R.; Stegnar, P.; Jovanovic, S.

    1990-01-01

    The k o -standardization method is suitable for routine multielement determinations by reactor neutron activation analysis (NAA). Investigation of NIST standard reference materials SRM 1571 Orchard Leaves, SRM 1572 Citrus leaves, and SRM 1573 Tomato Leaves showed the systematic error of 12 certified elements determined to be less than 8%. Thirty-four elements were determined in NIST proposed SRM 1515 Apple Leaves

  12. Standard test method for measurement of oxidation-reduction potential (ORP) of soil

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This test method covers a procedure and related test equipment for measuring oxidation-reduction potential (ORP) of soil samples removed from the ground. 1.2 The procedure in Section 9 is appropriate for field and laboratory measurements. 1.3 Accurate measurement of oxidation-reduction potential aids in the analysis of soil corrosivity and its impact on buried metallic structure corrosion rates. 1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  13. A standardized method for beam design in neutron capture therapy

    International Nuclear Information System (INIS)

    Storr, G.J.: Harrington, B.V.

    1993-01-01

    A desirable end point for a given beam design for Neutron Capture Therapy (NCT) should be quantitative description of tumour control probability and normal tissue damage. Achieving this goal will ultimately rely on data from NCT human clinical trials. Traditional descriptions of beam designs have used a variety of assessment methods to quantify proposed or installed beam designs. These methods include measurement and calculation of open-quotes free fieldclose quotes parameters, such as neutron and gamma flux intensities and energy spectra, and figures-of-merit in tissue equivalent phantoms. The authors propose here a standardized method for beam design in NCT. This method would allow all proposed and existing NCT beam facilities to be compared equally. The traditional approach to determining a quantitative description of tumour control probability and normal tissue damage in NCT research may be described by the following path: Beam design → dosimetry → macroscopic effects → microscopic effects. Methods exist that allow neutron and gamma fluxes and energy dependence to be calculated and measured to good accuracy. By using this information and intermediate dosimetric quantities such as kerma factors for neutrons and gammas, macroscopic effect (absorbed dose) in geometries of tissue or tissue-equivalent materials can be calculated. After this stage, for NCT the data begins to become more sparse and in some areas ambiguous. Uncertainties in the Relative Biological Effectiveness (RBE) of some NCT dose components means that beam designs based on assumptions considered valid a few years ago may have to be reassessed. A standard method is therefore useful for comparing different NCT facilities

  14. Standard test method for electrochemical critical pitting temperature testing of stainless steels

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1999-01-01

    1.1 This test method covers a procedure for the evaluation of the resistance of stainless steel and related alloys to pitting corrosion based on the concept of the determination of a potential independent critical pitting temperature (CPT). 1.2 This test methods applies to wrought and cast products including but not restricted to plate, sheet, tubing, bar, forgings, and welds, (see Note 1). Note 1—Examples of CPT measurements on sheet, plate, tubing, and welded specimens for various stainless steels can be found in Ref (1). See the research reports (Section 14). 1.3 The standard parameters recommended in this test method are suitable for characterizing the CPT of austenitic stainless steels and other related alloys with a corrosion resistance ranging from that corresponding to solution annealed UNS S31600 (Type 316 stainless steel) to solution annealed UNS S31254 (6 % Mo stainless steel). 1.4 This test method may be extended to stainless steels and other alloys related to stainless steel that have a CPT...

  15. American National Standard: guidelines for evaluating site-related geotechnical parameters at nuclear power sites

    International Nuclear Information System (INIS)

    Anon.

    1978-01-01

    This standard presents guidelines for evaluating site-related geotechnical parameters for nuclear power sites. Aspects considered include geology, ground water, foundation engineering, and earthwork engineering. These guidelines identify the basic geotechnical parameters to be considered in site evaluation, and in the design, construction, and performance of foundations and earthwork aspects for nuclear power plants. Also included are tabulations of typical field and laboratory investigative methods useful in identifying geotechnical parameters. Those areas where interrelationships with other standards may exist are indicated

  16. Application of a spectrum standardization method for carbon analysis in coal using laser-induced breakdown spectroscopy (LIBS).

    Science.gov (United States)

    Li, Xiongwei; Wang, Zhe; Fu, Yangting; Li, Zheng; Liu, Jianmin; Ni, Weidou

    2014-01-01

    Measurement of coal carbon content using laser-induced breakdown spectroscopy (LIBS) is limited by its low precision and accuracy. A modified spectrum standardization method was proposed to achieve both reproducible and accurate results for the quantitative analysis of carbon content in coal using LIBS. The proposed method used the molecular emissions of diatomic carbon (C2) and cyanide (CN) to compensate for the diminution of atomic carbon emissions in high volatile content coal samples caused by matrix effect. The compensated carbon line intensities were further converted into an assumed standard state with standard plasma temperature, electron number density, and total number density of carbon, under which the carbon line intensity is proportional to its concentration in the coal samples. To obtain better compensation for fluctuations of total carbon number density, the segmental spectral area was used and an iterative algorithm was applied that is different from our previous spectrum standardization calculations. The modified spectrum standardization model was applied to the measurement of carbon content in 24 bituminous coal samples. The results demonstrate that the proposed method has superior performance over the generally applied normalization methods. The average relative standard deviation was 3.21%, the coefficient of determination was 0.90, the root mean square error of prediction was 2.24%, and the average maximum relative error for the modified model was 12.18%, showing an overall improvement over the corresponding values for the normalization with segmental spectrum area, 6.00%, 0.75, 3.77%, and 15.40%, respectively.

  17. Standardization of waste acceptance test methods by the Materials Characterization Center

    International Nuclear Information System (INIS)

    Slate, S.C.

    1985-01-01

    This paper describes the role of standardized test methods in demonstrating the acceptability of high-level waste (HLW) forms for disposal. Key waste acceptance tests are standardized by the Materials Characterization Center (MCC), which the US Department of Energy (DOE) has established as the central agency in the United States for the standardization of test methods for nuclear waste materials. This paper describes the basic three-step process that is used to show that waste is acceptable for disposal and discusses how standardized tests are used in this process. Several of the key test methods and their areas of application are described. Finally, future plans are discussed for using standardized tests to show waste acceptance. 9 refs., 1 tab

  18. A standards-based method for compositional analysis by energy dispersive X-ray spectrometry using multivariate statistical analysis: application to multicomponent alloys.

    Science.gov (United States)

    Rathi, Monika; Ahrenkiel, S P; Carapella, J J; Wanlass, M W

    2013-02-01

    Given an unknown multicomponent alloy, and a set of standard compounds or alloys of known composition, can one improve upon popular standards-based methods for energy dispersive X-ray (EDX) spectrometry to quantify the elemental composition of the unknown specimen? A method is presented here for determining elemental composition of alloys using transmission electron microscopy-based EDX with appropriate standards. The method begins with a discrete set of related reference standards of known composition, applies multivariate statistical analysis to those spectra, and evaluates the compositions with a linear matrix algebra method to relate the spectra to elemental composition. By using associated standards, only limited assumptions about the physical origins of the EDX spectra are needed. Spectral absorption corrections can be performed by providing an estimate of the foil thickness of one or more reference standards. The technique was applied to III-V multicomponent alloy thin films: composition and foil thickness were determined for various III-V alloys. The results were then validated by comparing with X-ray diffraction and photoluminescence analysis, demonstrating accuracy of approximately 1% in atomic fraction.

  19. Mixed gamma emitting gas standard and method

    International Nuclear Information System (INIS)

    McFarland, R.C.; McFarland, P.A.

    1986-01-01

    The invention in one aspect pertains to a method of calibrating gamma spectroscopy systems for gas counting in a variety of counting containers comprising withdrawing a precision volume of a mixed gamma-emitting gas standard from a precision volume vial and delivering the withdrawn precision volume of the gas standard to the interior of a gas counting container. Another aspect of the invention pertains to a mixed gamma-emitting gas standard, comprising a precision spherical vial of predetermined volume, multiple mixed emitting gas components enclosed within the vial, and means for withdrawing from the vial a predetermined amount of the components wherein the gas standard is used to calibrate a gamma spectrometer system for gas counting over a wide energy range without the use of additional standards. A third aspect comprehends a gamma spectrometer calibration system for gas counting, comprising a precision volume spherical glass vial for receiving mixed multiisotope gas components, and two tubular arms extending from the vial. A ground glass stopcock is positioned on each arm, and the outer end of one arm is provided with a rubber septum port

  20. Standard Test Method for Measuring Binocular Disparity in Transparent Parts

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This test method covers the amount of binocular disparity that is induced by transparent parts such as aircraft windscreens, canopies, HUD combining glasses, visors, or goggles. This test method may be applied to parts of any size, shape, or thickness, individually or in combination, so as to determine the contribution of each transparent part to the overall binocular disparity present in the total “viewing system” being used by a human operator. 1.2 This test method represents one of several techniques that are available for measuring binocular disparity, but is the only technique that yields a quantitative figure of merit that can be related to operator visual performance. 1.3 This test method employs apparatus currently being used in the measurement of optical angular deviation under Method F 801. 1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not con...

  1. [Modified Delphi method in the constitution of school sanitation standard].

    Science.gov (United States)

    Yin, Xunqiang; Liang, Ying; Tan, Hongzhuan; Gong, Wenjie; Deng, Jing; Luo, Jiayou; Di, Xiaokang; Wu, Yue

    2012-11-01

    To constitute school sanitation standard using modified Delphi method, and to explore the feasibility and the predominance of Delphi method in the constitution of school sanitation standard. Two rounds of expert consultations were adopted in this study. The data were analyzed with SPSS15.0 to screen indices of school sanitation standard. Thirty-two experts accomplished the 2 rounds of consultations. The average length of expert service was (24.69 ±8.53) years. The authority coefficient was 0.729 ±0.172. The expert positive coefficient was 94.12% (32/34) in the first round and 100% (32/32) in the second round. The harmonious coefficients of importance, feasibility and rationality in the second round were 0.493 (PDelphi method is a rapid, effective and feasible method in this field.

  2. Quantitative angle-insensitive flow measurement using relative standard deviation OCT.

    Science.gov (United States)

    Zhu, Jiang; Zhang, Buyun; Qi, Li; Wang, Ling; Yang, Qiang; Zhu, Zhuqing; Huo, Tiancheng; Chen, Zhongping

    2017-10-30

    Incorporating different data processing methods, optical coherence tomography (OCT) has the ability for high-resolution angiography and quantitative flow velocity measurements. However, OCT angiography cannot provide quantitative information of flow velocities, and the velocity measurement based on Doppler OCT requires the determination of Doppler angles, which is a challenge in a complex vascular network. In this study, we report on a relative standard deviation OCT (RSD-OCT) method which provides both vascular network mapping and quantitative information for flow velocities within a wide range of Doppler angles. The RSD values are angle-insensitive within a wide range of angles, and a nearly linear relationship was found between the RSD values and the flow velocities. The RSD-OCT measurement in a rat cortex shows that it can quantify the blood flow velocities as well as map the vascular network in vivo .

  3. Improvement of precision method of spectrophotometry with inner standardization and its use in plutonium solutions analysis

    International Nuclear Information System (INIS)

    Stepanov, A.V.; Stepanov, D.A.; Nikitina, S.A.; Gogoleva, T.D.; Grigor'eva, M.G.; Bulyanitsa, L.S.; Panteleev, Yu.A.; Pevtsova, E.V.; Domkin, V.D.; Pen'kin, M.V.

    2006-01-01

    Precision method of spectrophotometry with inner standardization is used for analysis of pure Pu solutions. Improvement of the spectrophotometer and spectrophotometric method of analysis is done to decrease accidental constituent of relative error of the method. Influence of U, Np impurities and corrosion products on systematic constituent of error of the method, and effect of fluoride-ion on completeness of Pu oxidation in sample preparation are studied [ru

  4. Standard guide for qualification of measurement methods by a laboratory within the nuclear industry

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2003-01-01

    1.1 This guide provides guidance for selecting, validating, and qualifying measurement methods when qualification is required for a specific program. The recommended practices presented in this guide provide a major part of a quality assurance program for the laboratory data (see Fig. 1). Qualification helps to assure that the data produced will meet established requirements. 1.2 The activities intended to assure the quality of analytical laboratory measurement data are diagrammed in Fig. 1. Discussion and guidance related to some of these activities appear in the following sections: Section Selection of Measurement Methods 5 Validation of Measurement Methods 6 Qualification of Measurement Methods 7 Control 8 Personnel Qualification 9 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitati...

  5. Method for matching customer and manufacturer positions for metal product parameters standardization

    Science.gov (United States)

    Polyakova, Marina; Rubin, Gennadij; Danilova, Yulija

    2018-04-01

    Decision making is the main stage of regulation the relations between customer and manufacturer during the design the demands of norms in standards. It is necessary to match the positions of the negotiating sides in order to gain the consensus. In order to take into consideration the differences of customer and manufacturer estimation of the object under standardization process it is obvious to use special methods of analysis. It is proposed to establish relationships between product properties and its functions using functional-target analysis. The special feature of this type of functional analysis is the consideration of the research object functions and properties. It is shown on the example of hexagonal head crew the possibility to establish links between its functions and properties. Such approach allows obtaining a quantitative assessment of the closeness the positions of customer and manufacturer at decision making during the standard norms establishment.

  6. Changes in IEC standards related to diagnostic radiology

    International Nuclear Information System (INIS)

    Porubszky, T.; Barsai, J.

    2007-01-01

    Complete test of publication follows. Purposes. Technical Committee TC62 of International Electrotechnical Commission (IEC) deals with medical electrical equipment (i.e. medical devices using electricity). Standardization concerning diagnostic radiology equipment is task of its Sub-Committee SC62B. An outlook of its activities and present situation, and especially of radiation protection aspects, is given. Materials and methods. Third edition of basic safety standard for medical electrical equipment IEC 60601-1 was issued in 2005. Elaboration of new collateral and particular standards - applicable together with it - is in progress. These standards are generally at the same time also European - EN - and national standards. There is a great importance of radiation protection in diagnostic X-ray equipment. Collateral standard IEC 6060-1-3 about it was at first issued in 1994. Rapid development of imaging technology demands updating of requirements. SC62B in 2003 founded a maintenance team MT37 for preparation of the second edition of this standard. According to new safety philosophy of IEC all modality specific requirements are to be collected in 'safety and essential performance' particular standards. A new working group WG42 - founded in 2006 - elaborates a new particular standard IEC 60601-2-54 for radiographic and radioscopic equipment. Maintenance team MT32 deals with safety and performance standards for X-ray tube assemblies. The authors actively participate in these activities. Results and discussion. Present and future system of diagnostic radiology IEC standards and some interesting details are presented. Conclusions. International standards - although they are not 'obligatory' - are generally the basis of safety and performance certification of diagnostic radiology equipment and often also of their quality assurance.

  7. Statistical methods for evaluating the attainment of cleanup standards

    Energy Technology Data Exchange (ETDEWEB)

    Gilbert, R.O.; Simpson, J.C.

    1992-12-01

    This document is the third volume in a series of volumes sponsored by the US Environmental Protection Agency (EPA), Statistical Policy Branch, that provide statistical methods for evaluating the attainment of cleanup Standards at Superfund sites. Volume 1 (USEPA 1989a) provides sampling designs and tests for evaluating attainment of risk-based standards for soils and solid media. Volume 2 (USEPA 1992) provides designs and tests for evaluating attainment of risk-based standards for groundwater. The purpose of this third volume is to provide statistical procedures for designing sampling programs and conducting statistical tests to determine whether pollution parameters in remediated soils and solid media at Superfund sites attain site-specific reference-based standards. This.document is written for individuals who may not have extensive training or experience with statistical methods. The intended audience includes EPA regional remedial project managers, Superfund-site potentially responsible parties, state environmental protection agencies, and contractors for these groups.

  8. Standard test method for determination of surface lubrication on flexible webs

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1999-01-01

    1.1 This test method has been used since 1988 as an ANSI/ISO standard test for determination of lubrication on processed photographic films. Its purpose was to determine the presence of process-surviving lubricants on photographic films. It is the purpose of this test method to expand the applicability of this test method to other flexible webs that may need lubrication for suitable performance. This test measures the breakaway (static) coefficient of friction of a metal rider on the web by the inclined plane method. The objectives of the test is to determine if a web surface has a lubricant present or not. It is not intended to assign a friction coefficient to a material. It is not intended to rank lubricants. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish ...

  9. Computer-related standards for the petroleum industry

    International Nuclear Information System (INIS)

    Winczewski, L.M.

    1992-01-01

    Rapid application of the computer to all areas of the petroleum industry is straining the capabilities of corporations and vendors to efficiently integrate computer tools into the work environment. Barriers to this integration arose form decades of competitive development of proprietary applications formats, along with compilation of data bases in isolation. Rapidly emerging industry-wide standards relating to computer applications and data management are poised to topple these barriers. This paper identifies the most active players within a rapidly evolving group of cooperative standardization activities sponsored by the petroleum industry. Summarized are their objectives, achievements, current activities and relationships to each other. The trends of these activities are assessed and projected

  10. Standard test method for dynamic tear testing of metallic materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1983-01-01

    1.1 This test method covers the dynamic tear (DT) test using specimens that are 3/16 in. to 5/8 in. (5 mm to 16 mm) inclusive in thickness. 1.2 This test method is applicable to materials with a minimum thickness of 3/16 in. (5 mm). 1.3 The pressed-knife procedure described for sharpening the notch tip generally limits this test method to materials with a hardness level less than 36 HRC. Note 1—The designation 36 HRC is a Rockwell hardness number of 36 on Rockwell C scale as defined in Test Methods E 18. 1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  11. Fault Diagnosis Method Based on Information Entropy and Relative Principal Component Analysis

    Directory of Open Access Journals (Sweden)

    Xiaoming Xu

    2017-01-01

    Full Text Available In traditional principle component analysis (PCA, because of the neglect of the dimensions influence between different variables in the system, the selected principal components (PCs often fail to be representative. While the relative transformation PCA is able to solve the above problem, it is not easy to calculate the weight for each characteristic variable. In order to solve it, this paper proposes a kind of fault diagnosis method based on information entropy and Relative Principle Component Analysis. Firstly, the algorithm calculates the information entropy for each characteristic variable in the original dataset based on the information gain algorithm. Secondly, it standardizes every variable’s dimension in the dataset. And, then, according to the information entropy, it allocates the weight for each standardized characteristic variable. Finally, it utilizes the relative-principal-components model established for fault diagnosis. Furthermore, the simulation experiments based on Tennessee Eastman process and Wine datasets demonstrate the feasibility and effectiveness of the new method.

  12. Development of standard testing methods for nuclear-waste forms

    International Nuclear Information System (INIS)

    Mendel, J.E.; Nelson, R.D.

    1981-11-01

    Standard test methods for waste package component development and design, safety analyses, and licensing are being developed for the Nuclear Waste Materials Handbook. This paper describes mainly the testing methods for obtaining waste form materials data

  13. Evaluation Standard for Safety Coefficient of Roller Compacted Concrete Dam Based on Finite Element Method

    Directory of Open Access Journals (Sweden)

    Bo Li

    2014-01-01

    Full Text Available The lack of evaluation standard for safety coefficient based on finite element method (FEM limits the wide application of FEM in roller compacted concrete dam (RCCD. In this paper, the strength reserve factor (SRF method is adopted to simulate gradual failure and possible unstable modes of RCCD system. The entropy theory and catastrophe theory are used to obtain the ultimate bearing resistance and failure criterion of the RCCD. The most dangerous sliding plane for RCCD failure is found using the Latin hypercube sampling (LHS and auxiliary analysis of partial least squares regression (PLSR. Finally a method for determining the evaluation standard of RCCD safety coefficient based on FEM is put forward using least squares support vector machines (LSSVM and particle swarm optimization (PSO. The proposed method is applied to safety coefficient analysis of the Longtan RCCD in China. The calculation shows that RCCD failure is closely related to RCCD interface strength, and the Longtan RCCD is safe in the design condition. Considering RCCD failure characteristic and combining the advantages of several excellent algorithms, the proposed method determines the evaluation standard for safety coefficient of RCCD based on FEM for the first time and can be popularized to any RCCD.

  14. Standard Test Method for Measuring Fast-Neutron Reaction Rates by Radioactivation of Titanium

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 This test method covers procedures for measuring reaction rates by the activation reactions 46Ti(n,p) 46Sc + 47Ti(n, np)46Sc. Note 1—Since the cross section for the (n,np) reaction is relatively small for energies less than 12 MeV and is not easily distinguished from that of the (n,p) reaction, this test method will refer to the (n,p) reaction only. 1.2 The reaction is useful for measuring neutrons with energies above approximately 4.4 MeV and for irradiation times up to about 250 days (for longer irradiations, see Practice E 261). 1.3 With suitable techniques, fission-neutron fluence rates above 109 cm–2·s–1 can be determined. However, in the presence of a high thermal-neutron fluence rate, 46Sc depletion should be investigated. 1.4 Detailed procedures for other fast-neutron detectors are referenced in Practice E 261. 1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.6 This standard does not purport to address all...

  15. Development of A Standard Method for Human Reliability Analysis of Nuclear Power Plants

    International Nuclear Information System (INIS)

    Jung, Won Dea; Kang, Dae Il; Kim, Jae Whan

    2005-12-01

    According as the demand of risk-informed regulation and applications increase, the quality and reliability of a probabilistic safety assessment (PSA) has been more important. KAERI started a study to standardize the process and the rules of HRA (Human Reliability Analysis) which was known as a major contributor to the uncertainty of PSA. The study made progress as follows; assessing the level of quality of the HRAs in Korea and identifying the weaknesses of the HRAs, determining the requirements for developing a standard HRA method, developing the process and rules for quantifying human error probability. Since the risk-informed applications use the ASME PSA standard to ensure PSA quality, the standard HRA method was developed to meet the ASME HRA requirements with level of category II. The standard method was based on THERP and ASEP HRA that are widely used for conventional HRA. However, the method focuses on standardizing and specifying the analysis process, quantification rules and criteria to minimize the deviation of the analysis results caused by different analysts. Several HRA experts from different organizations in Korea participated in developing the standard method. Several case studies were interactively undertaken to verify the usability and applicability of the standard method

  16. Development of A Standard Method for Human Reliability Analysis of Nuclear Power Plants

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Won Dea; Kang, Dae Il; Kim, Jae Whan

    2005-12-15

    According as the demand of risk-informed regulation and applications increase, the quality and reliability of a probabilistic safety assessment (PSA) has been more important. KAERI started a study to standardize the process and the rules of HRA (Human Reliability Analysis) which was known as a major contributor to the uncertainty of PSA. The study made progress as follows; assessing the level of quality of the HRAs in Korea and identifying the weaknesses of the HRAs, determining the requirements for developing a standard HRA method, developing the process and rules for quantifying human error probability. Since the risk-informed applications use the ASME PSA standard to ensure PSA quality, the standard HRA method was developed to meet the ASME HRA requirements with level of category II. The standard method was based on THERP and ASEP HRA that are widely used for conventional HRA. However, the method focuses on standardizing and specifying the analysis process, quantification rules and criteria to minimize the deviation of the analysis results caused by different analysts. Several HRA experts from different organizations in Korea participated in developing the standard method. Several case studies were interactively undertaken to verify the usability and applicability of the standard method.

  17. Utility and performance relative to consumer product energy efficiency standards. Final technical report

    Energy Technology Data Exchange (ETDEWEB)

    Coggins, J.L.

    1979-12-14

    An investigation of the relative utility and performance of nine major household consumer products covered by the Energy Policy and Conservation Act is summarized. The objective was to define the terms utility and performance, to recommend methods for quantifying these two concepts, and to recommend an approach for dealing with utility and performance issues in the energy efficiency standards program. The definitions developed are: performance of a consumer product is the objective measure of how well, with the expected level of consumer input (following the manufacturer's instructions for installation and operation), the product does its intended job; and utility of a consumer product is a subjective measure, based on the consumer's perception, of the capability of the product to satisfy human needs. Quantification is based on test procedures and consumer survey methods which are largely already in use by industry. Utility and performance issues are important in product classification for prescribing energy efficiency standards. The recommended approach to utility and performance issues and classification is: prior to setting standards, evaluate utility and performance issues in the most quantitative way allowed by resources and schedules in order to develop classification guidelines. This approach requires no changes in existing Department of Energy test procedures.

  18. Standardized waste form test methods

    International Nuclear Information System (INIS)

    Slate, S.C.

    1984-01-01

    The Materials Characterization Center (MCC) is developing standard tests to characterize nuclear waste forms. Development of the first thirteen tests was originally initiated to provide data to compare different high-level waste (HLW) forms and to characterize their basic performance. The current status of the first thirteen MCC tests and some sample test results are presented: the radiation stability tests (MCC-6 and 12) and the tensile-strength test (MCC-11) are approved; the static leach tests (MCC-1, 2, and 3) are being reviewed for full approval; the thermal stability (MCC-7) and microstructure evaluation (MCC-13) methods are being considered for the first time; and the flowing leach test methods (MCC-4 and 5), the gas generation methods (MCC-8 and 9), and the brittle fracture method (MCC-10) are indefinitely delayed. Sample static leach test data on the ARM-1 approved reference material are presented. Established tests and proposed new tests will be used to meet new testing needs. For waste form production, tests on stability and composition measurement are needed to provide data to ensure waste form quality. In transporation, data are needed to evaluate the effects of accidents on canisterized waste forms. The new MCC-15 accident test method and some data are presented. Compliance testing needs required by the recent draft repository waste acceptance specifications are described. These specifications will control waste form contents, processing, and performance

  19. Standardized waste form test methods

    International Nuclear Information System (INIS)

    Slate, S.C.

    1984-11-01

    The Materials Characterization Center (MCC) is developing standard tests to characterize nuclear waste forms. Development of the first thirteen tests was originally initiated to provide data to compare different high-level waste (HLW) forms and to characterize their basic performance. The current status of the first thirteen MCC tests and some sample test results is presented: The radiation stability tests (MCC-6 and 12) and the tensile-strength test (MCC-11) are approved; the static leach tests (MCC-1, 2, and 3) are being reviewed for full approval; the thermal stability (MCC-7) and microstructure evaluation (MCC-13) methods are being considered for the first time; and the flowing leach tests methods (MCC-4 and 5), the gas generation methods (MCC-8 and 9), and the brittle fracture method (MCC-10) are indefinitely delayed. Sample static leach test data on the ARM-1 approved reference material are presented. Established tests and proposed new tests will be used to meet new testing needs. For waste form production, tests on stability and composition measurement are needed to provide data to ensure waste form quality. In transportation, data are needed to evaluate the effects of accidents on canisterized waste forms. The new MCC-15 accident test method and some data are presented. Compliance testing needs required by the recent draft repository waste acceptance specifications are described. These specifications will control waste form contents, processing, and performance. 2 references, 2 figures

  20. Standard Test Method for Abrasive Wear Resistance of Cemented

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2005-01-01

    1.1 This test method covers the determination of abrasive wear resistance of cemented carbides. 1.2 The values stated in inch-pound units are to be regarded as the standard. The SI equivalents of inch-pound units are in parentheses and may be approximate. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  1. Relations between the technological standards and technological appropriation

    Directory of Open Access Journals (Sweden)

    Carlos Alberto PRADO GUERRERO

    2010-06-01

    Full Text Available The objective of this study is to analyze the educational practices of using Blackboard in blended learning environments with students of higher education to understand the relationship between technological appropriation and standards of educational technology. To achieve that goal, the following research question was raised: ¿To what extent are the standards of education technology with the appropriation of technology in blended learning environments in higher educa­tion related? The contextual framework of this work includes the following topics: the institution, teaching, teachers and students. The design methodology that was used is of a correlation type. Correlations were carried out to determine the frequency and level in the technological standards as well as the appropriation of technology. In the comparison of the results obtained by the students, the teachers and the platform; we found that students in the school study showed a high degree of technology ownership and this was the same for the performance shown on the technological standards. It was established that teachers play a key role in developing the techno­logical appropriation of students and performance in technology standards.

  2. Standard Test Method for Wet Insulation Integrity Testing of Photovoltaic Arrays

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This test method covers a procedure to determine the insulation resistance of a photovoltaic (PV) array (or its component strings), that is, the electrical resistance between the array's internal electrical components and is exposed, electrically conductive, non-current carrying parts and surfaces of the array. 1.2 This test method does not establish pass or fail levels. The determination of acceptable or unacceptable results is beyond the scope of this test method. 1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  3. Handbook for Conducting Standard CMMI Appraisal Method for Process Improvement (SCAMPI) B and C Appraisals, Version 1.1

    National Research Council Canada - National Science Library

    Hayes, Will; Miluk, Gene; Ming, Lisa; Glover, Margaret; Bisgrove, Jane; Cort, Corrine; Penn, Lynn; Jacobson, Nils; Beynon, Don; Allgood, Bruce

    2005-01-01

    The Standard CMMI Appraisal Method for Process Improvement (SCAMPI) provides a well-defined, publicly available set of methodologies for providing appraisals relative to Capability Maturity Model (trademark) Integration (CMMI) models...

  4. Standard test method for measurement of web/roller friction characteristics

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2003-01-01

    1.1 This test method covers the simulation of a roller/web transport tribosystem and the measurement of the static and kinetic coefficient of friction of the web/roller couple when sliding occurs between the two. The objective of this test method is to provide users with web/roller friction information that can be used for process control, design calculations, and for any other function where web/roller friction needs to be known. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  5. Statistical benchmarking in utility regulation: Role, standards and methods

    International Nuclear Information System (INIS)

    Newton Lowry, Mark; Getachew, Lullit

    2009-01-01

    Statistical benchmarking is being used with increasing frequency around the world in utility rate regulation. We discuss how and where benchmarking is in use for this purpose and the pros and cons of regulatory benchmarking. We then discuss alternative performance standards and benchmarking methods in regulatory applications. We use these to propose guidelines for the appropriate use of benchmarking in the rate setting process. The standards, which we term the competitive market and frontier paradigms, have a bearing on method selection. These along with regulatory experience suggest that benchmarking can either be used for prudence review in regulation or to establish rates or rate setting mechanisms directly

  6. Standard test method for measurement of soil resistivity using the two-electrode soil box method

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2005-01-01

    1.1 This test method covers the equipment and a procedure for the measurement of soil resistivity, for samples removed from the ground, for use in the control of corrosion of buried structures. 1.2 Procedures allow for this test method to be used n the field or in the laboratory. 1.3 The test method procedures are for the resistivity measurement of soil samples in the saturated condition and in the as-received condition. 1.4 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only. Soil resistivity values are reported in ohm-centimeter. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and to determine the applicability of regulatory limitations prior to use.

  7. The relative-intensity method of X-ray fluorescence analysis and its application to soils and rocks

    International Nuclear Information System (INIS)

    Childs, C.W.; Furkert, R.J.

    1974-01-01

    The relative-intensity X-ray fluorescence method of analysis of rock and soil samples has been investigated and compared with the net-intensity method. Strong, coherently scattered radiation originating from the X-ray tube is shown to be preferable to background radiation as an internal standard, and scattered radiation measured at one wavelength can usefully be applied in the determination of several elements. When the concentrations of an element in two soil samples of different composition (for example concretions and the soil adjacent to them) are compared, the ratio of the relative intensities may be different from the ratio of net intensities by a factor of about two. The concentrations of manganese in thirteen standard rock samples determined by the relative-intensity method are within or very close to the ranges of values reported previously

  8. IEEE Std 382-1985: IEEE standard for qualification of actuators for power operated valve assemblies with safety-related functions for nuclear power plants

    International Nuclear Information System (INIS)

    Anon.

    1992-01-01

    This standard describes the qualification of all types of power-driven valve actuators, including damper actuators, for safety-related functions in nuclear power generating stations. This standard may also be used to separately qualify actuator components. This standard establishes the minimum requirements for, and guidance regarding, the methods and procedures for qualification of power-driven valve actuators with safety-related functions Part I describes the qualification process. Part II describes the standard qualification cases and their environmental parameters for the usual locations of safety-related equipment in a nuclear generating station. Part III describes the qualification tests outlined in 6.3.3

  9. Standard methods for sampling freshwater fishes: opportunities for international collaboration

    OpenAIRE

    Bonar, Scott A.; Mercado-Silva, Norman; Hubert, Wayne A.; Beard, T. Douglas; Dave, Göran; Kubečka, Jan; Graeb, Brian D.S.; Lester, Nigel P.; Porath, Mark; Winfield, Ian J.

    2017-01-01

    With publication of Standard Methods for Sampling North American Freshwater Fishes in 2009, the American Fisheries Society (AFS) recommended standard procedures for North America. To explore interest in standardizing at intercontinental scales, a symposium attended by international specialists in freshwater fish sampling was convened at the 145th Annual AFS Meeting in Portland, Oregon, in August 2015. Participants represented all continents except Australia and Antarctica and were employed by...

  10. The new fabrication method of standard surface sources

    Energy Technology Data Exchange (ETDEWEB)

    Sato, Yasushi E-mail: yss.sato@aist.go.jp; Hino, Yoshio; Yamada, Takahiro; Matsumoto, Mikio

    2004-04-01

    We developed a new fabrication method for standard surface sources by using an inkjet printer with inks in which a radioactive material is mixed to print on a sheet of paper. Three printed test patterns have been prepared: (1) 100 mmx100 mm uniformity-test patterns, (2) positional-resolution test patterns with different widths and intervals of straight lines, and (3) logarithmic intensity test patterns with different radioactive intensities. The results revealed that the fabricated standard surface sources had high uniformity, high positional resolution, arbitrary shapes and a broad intensity range.

  11. Comparisons of ANS, ASME, AWS, and NFPA standards cited in the NRC standard review plan, NUREG-0800, and related documents

    International Nuclear Information System (INIS)

    Ankrum, A.R.; Bohlander, K.L.; Gilbert, E.R.; Spiesman, J.B.

    1995-11-01

    This report provides the results of comparisons of the cited and latest versions of ANS, ASME, AWS and NFPA standards cited in the NRC Standard Review Plan for the Review of Safety Analysis Reports for Nuclear Power Plants (NUREG 0800) and related documents. The comparisons were performed by Battelle Pacific Northwest Laboratories in support of the NRC's Standard Review Plan Update and Development Program. Significant changes to the standards, from the cited version to the latest version, are described and discussed in a tabular format for each standard. Recommendations for updating each citation in the Standard Review Plan are presented. Technical considerations and suggested changes are included for related regulatory documents (i.e., Regulatory Guides and the Code of Federal Regulations) citing the standard. The results and recommendations presented in this document have not been subjected to NRC staff review

  12. Equivalence factors for standardizing catch data across multiple beach seine nets to account for differences in relative bias

    Science.gov (United States)

    Hallett, Chris S.; Hall, Norm G.

    2012-06-01

    We describe a method for modelling the relative effects of seine net biases and for deriving equivalence factors to standardize fish abundance data sets collected using multiple sampling gears. Nearshore fish communities were sampled from 10 sites in each of the basin and riverine portions of the Swan-Canning Estuary, Western Australia, using beach seine nets of three different lengths (21.5, 41.5 and 133 m). The resulting data were subjected to generalized linear modelling to derive equivalence factors relating catches from the two larger net types to those from the 21.5 m net. Equivalence factors were derived on the basis of functional habitat guilds of fish (small benthic, small pelagic, demersal, pelagic). Prior to standardization, catches from the 41.5 and 133 m nets consistently underestimated fish densities relative to those from the 21.5 m net. Following standardization, the degree to which fish densities were underestimated by the two larger nets was reduced and/or eliminated for most guilds, and particularly in the case of the 133 m net. For both of the larger nets, standardized estimates of total fish density across all species were far closer to those recorded using the 21.5 m seine, thus indicating that standardization of the fish abundance data had greatly reduced the overall effects of the biases introduced by the different net types. This approach could be applied to other systems and sampling methods, to facilitate more robust comparisons of fish abundances between studies with divergent sampling methodologies.

  13. Improvement of Cost Calculation in Constructions – Application of the Standard Cost Method

    Directory of Open Access Journals (Sweden)

    Adela Breuer

    2010-12-01

    Full Text Available Grace to the analysis of several commercial companies effectively performed “on the field”, we could remark the necessity to change the method of cost calculation, our motivation being related to the simplification of calculations and the reduction of the labour volume, but especially the necessity to know in due time the deviations occurred as well as the causes having led to their apparition. The importance of knowing the deviations in due time results from the very basic characteristics of the constructions execution, i.e. the performance of works during several budgetary years, which leads to the modifications of prices and materials, the introduction of new technologies, and to the performance of open air activities, making the execution of constructions works be influenced by the atmospheric condition. But the most important aspect of knowing the deviations is the correct determination of expenses and their inscribing in the corresponding period, in view of determining the result of the budgetary year. Our proposal for the enhancement of the method of cost calculation in constructions is the application of the standard cost method in the variant “single standard cost”.

  14. Vaginismus and dyspareunia: relationship with general and sex-related moral standards.

    Science.gov (United States)

    Borg, Charmaine; de Jong, Peter J; Weijmar Schultz, Willibrord

    2011-01-01

    Relatively strong adherence to conservative values and/or relatively strict sex-related moral standards logically restricts the sexual repertoire and will lower the threshold for experiencing negative emotions in a sexual context. In turn, this may generate withdrawal and avoidance behavior, which is at the nucleus of vaginismus. To examine whether indeed strong adherence to conservative morals and/or strict sexual standards may be involved in vaginismus. The Schwartz Value Survey (SVS) to investigate the individual's value pattern and the Sexual Disgust Questionnaire (SDQ) to index the willingness to perform certain sexual activities as an indirect measure of sex-related moral standards. The SVS and SDQ were completed by three groups: women diagnosed with vaginismus (N=24), a group of women diagnosed with dyspareunia (N=24), and a healthy control group of women without sexual complaints (N=32). Specifically, the vaginismus group showed relatively low scores on liberal values together with comparatively high scores on conservative values. Additionally, the vaginismus group was more restricted in their readiness to perform particular sex-related behaviors than the control group. The dyspareunia group, on both the SVS and the SDQ, placed between the vaginismus and the control group, but not significantly different than either of the groups. The findings are consistent with the view that low liberal and high conservative values, along with restricted sexual standards, are involved in the development/maintenance of vaginismus. © 2010 International Society for Sexual Medicine.

  15. Internal standard method for determination of gallium and some trace elements in bauxite by neutron activation analysis

    International Nuclear Information System (INIS)

    Chen, S.G.; Tsai, H.T.

    1983-01-01

    A method is described for the determination of gallium and other trace elements such as Ce, Cr, Hf, Lu and Th in bauxite by the technique of neutron activation analysis using gold as internal standard. Isopropyl ether was used as organic extractant radioactive gallium from the sample. This method yields very good accuracy with a relative error of +-3%. (author)

  16. Cleanup standards and pathways analysis methods

    International Nuclear Information System (INIS)

    Devgun, J.S.

    1993-01-01

    Remediation of a radioactively contaminated site requires that certain regulatory criteria be met before the site can be released for unrestricted future use. Since the ultimate objective of remediation is to protect the public health and safety, residual radioactivity levels remaining at a site after cleanup must be below certain preset limits or meet acceptable dose or risk criteria. Release of a decontaminated site requires proof that the radiological data obtained from the site meet the regulatory criteria for such a release. Typically release criteria consist of a composite of acceptance limits that depend on the radionuclides, the media in which they are present, and federal and local regulations. In recent years, the US Department of Energy (DOE) has developed a pathways analysis model to determine site-specific soil activity concentration guidelines for radionuclides that do not have established generic acceptance limits. The DOE pathways analysis computer code (developed by Argonne National Laboratory for the DOE) is called RESRAD (Gilbert et al. 1989). Similar efforts have been initiated by the US Nuclear Regulatory Commission (NRC) to develop and use dose-related criteria based on genetic pathways analyses rather than simplistic numerical limits on residual radioactivity. The focus of this paper is radionuclide contaminated soil. Cleanup standards are reviewed, pathways analysis methods are described, and an example is presented in which RESRAD was used to derive cleanup guidelines

  17. Standard test method for plutonium assay by plutonium (III) diode array spectrophotometry

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2002-01-01

    1.1 This test method describes the determination of total plutonium as plutonium(III) in nitrate and chloride solutions. The technique is applicable to solutions of plutonium dioxide powders and pellets (Test Methods C 697), nuclear grade mixed oxides (Test Methods C 698), plutonium metal (Test Methods C 758), and plutonium nitrate solutions (Test Methods C 759). Solid samples are dissolved using the appropriate dissolution techniques described in Practice C 1168. The use of this technique for other plutonium-bearing materials has been reported (1-5), but final determination of applicability must be made by the user. The applicable concentration range for plutonium sample solutions is 10–200 g Pu/L. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropria...

  18. Normalization method for metabolomics data using optimal selection of multiple internal standards

    Directory of Open Access Journals (Sweden)

    Yetukuri Laxman

    2007-03-01

    Full Text Available Abstract Background Success of metabolomics as the phenotyping platform largely depends on its ability to detect various sources of biological variability. Removal of platform-specific sources of variability such as systematic error is therefore one of the foremost priorities in data preprocessing. However, chemical diversity of molecular species included in typical metabolic profiling experiments leads to different responses to variations in experimental conditions, making normalization a very demanding task. Results With the aim to remove unwanted systematic variation, we present an approach that utilizes variability information from multiple internal standard compounds to find optimal normalization factor for each individual molecular species detected by metabolomics approach (NOMIS. We demonstrate the method on mouse liver lipidomic profiles using Ultra Performance Liquid Chromatography coupled to high resolution mass spectrometry, and compare its performance to two commonly utilized normalization methods: normalization by l2 norm and by retention time region specific standard compound profiles. The NOMIS method proved superior in its ability to reduce the effect of systematic error across the full spectrum of metabolite peaks. We also demonstrate that the method can be used to select best combinations of standard compounds for normalization. Conclusion Depending on experiment design and biological matrix, the NOMIS method is applicable either as a one-step normalization method or as a two-step method where the normalization parameters, influenced by variabilities of internal standard compounds and their correlation to metabolites, are first calculated from a study conducted in repeatability conditions. The method can also be used in analytical development of metabolomics methods by helping to select best combinations of standard compounds for a particular biological matrix and analytical platform.

  19. Development of A Standard Method for Human Reliability Analysis (HRA) of Nuclear Power Plants

    International Nuclear Information System (INIS)

    Kang, Dae Il; Jung, Won Dea; Kim, Jae Whan

    2005-12-01

    According as the demand of risk-informed regulation and applications increase, the quality and reliability of a probabilistic safety assessment (PSA) has been more important. KAERI started a study to standardize the process and the rules of HRA (Human Reliability Analysis) which was known as a major contributor to the uncertainty of PSA. The study made progress as follows; assessing the level of quality of the HRAs in Korea and identifying the weaknesses of the HRAs, determining the requirements for developing a standard HRA method, developing the process and rules for quantifying human error probability. Since the risk-informed applications use the ASME and ANS PSA standard to ensure PSA quality, the standard HRA method was developed to meet the ASME and ANS HRA requirements with level of category II. The standard method was based on THERP and ASEP HRA that are widely used for conventional HRA. However, the method focuses on standardizing and specifying the analysis process, quantification rules and criteria to minimize the deviation of the analysis results caused by different analysts. Several HRA experts from different organizations in Korea participated in developing the standard method. Several case studies were interactively undertaken to verify the usability and applicability of the standard method

  20. Development of A Standard Method for Human Reliability Analysis (HRA) of Nuclear Power Plants

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Dae Il; Jung, Won Dea; Kim, Jae Whan

    2005-12-15

    According as the demand of risk-informed regulation and applications increase, the quality and reliability of a probabilistic safety assessment (PSA) has been more important. KAERI started a study to standardize the process and the rules of HRA (Human Reliability Analysis) which was known as a major contributor to the uncertainty of PSA. The study made progress as follows; assessing the level of quality of the HRAs in Korea and identifying the weaknesses of the HRAs, determining the requirements for developing a standard HRA method, developing the process and rules for quantifying human error probability. Since the risk-informed applications use the ASME and ANS PSA standard to ensure PSA quality, the standard HRA method was developed to meet the ASME and ANS HRA requirements with level of category II. The standard method was based on THERP and ASEP HRA that are widely used for conventional HRA. However, the method focuses on standardizing and specifying the analysis process, quantification rules and criteria to minimize the deviation of the analysis results caused by different analysts. Several HRA experts from different organizations in Korea participated in developing the standard method. Several case studies were interactively undertaken to verify the usability and applicability of the standard method.

  1. Standard Test Methods for Wet Insulation Integrity Testing of Photovoltaic Modules

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2007-01-01

    1.1 These test methods provide procedures to determine the insulation resistance of a photovoltaic (PV) module, i.e. the electrical resistance between the module's internal electrical components and its exposed, electrically conductive, non-current carrying parts and surfaces. 1.2 The insulation integrity procedures are a combination of wet insulation resistance and wet dielectric voltage withstand test procedures. 1.3 These procedures are similar to and reference the insulation integrity test procedures described in Test Methods E 1462, with the difference being that the photovoltaic module under test is immersed in a wetting solution during the procedures. 1.4 These test methods do not establish pass or fail levels. The determination of acceptable or unacceptable results is beyond the scope of these test methods. 1.5 The values stated in SI units are to be regarded as the standard. 1.6 There is no similar or equivalent ISO standard. 1.7 This standard does not purport to address all of the safety conce...

  2. Uncertainty and minimum detectable concentrations using relative, absolute and K*0-IAEA standardization for the INAA laboratory of the ETRR-2

    International Nuclear Information System (INIS)

    Khalil, M. Y.

    2006-01-01

    Full text: The Instrumental Neutron Activation Analysis (INAA) Laboratory of Egypt Second Training and Research Reactor (ETRR-2) is increasingly requested to perform multi-element analysis to large number of samples from different origins. The INAA laboratory has to demonstrate competence by conforming to appropriate internationally and nationally accepted standards. The objective of this work is to determine the uncertainty budget and sensitivity of the INAA laboratory measurements. Concentrations of 9 elements; Mn, Na, K, Ca, Co, Cr, Fe, Rb, and Cs, were measured against a certified test sample. Relative, absolute, and Ko-IAEA standardization methods were employed and results compared. The flux was monitored using cadmium covered gold method, and multifoil (gold, nickel and zirconium) method. The combined and expanded uncertainties were estimated. Uncertainty of concentrations ranged between 2-21% depending on the standardization method used. The relative method, giving the lowest uncertainty, produced uncertainty budget between 2 and 11%. The minimum detectable concentration was the lowest for Cs ranging between 0.36 and 0.59 ppb and the highest being for K in the range of 0.32 to 8.64 ppm

  3. An endogenous standard, radioisotopic ratio method in NAA

    International Nuclear Information System (INIS)

    Byrne, A.R.; Dermelj, M.

    1997-01-01

    A derivative form of NAA is proposed which is based on the use of an endogenous internal standard of already known concentration in the sample. If a comparator with a known ratio of the determinand and endogenous standard are co-irradiated with the sample, the determinand concentration is derived in terms of the endogenous standard concentration and the activity ratios of the two induced nuclides in the sample and comparator. As well as eliminating the sample mass and greatly reducing errors caused by pulse pile-up and geometrical differences, it was shown that in the radiochemical mode, if the endogenous standard is chosen so that the induced activity is radioisotopic with that from the determinand, the radiochemical yield is also eliminated and the risk non-achievement of isotopic exchange greatly reduced. The method is demonstrated with good results on reference materials for the determination of I, Mn and Ni. The advantages and disadvantages of this approach are discussed. It is suggested that it may be of application in quality control and in extending the range of certified elements in reference materials. (author)

  4. Evaluating the Capacity of Standard Investment Appraisal Methods

    NARCIS (Netherlands)

    M.M. Akalu

    2002-01-01

    textabstractThe survey findings indicate the existence of gap between theory and practice of capital budgeting. Standard appraisal methods have shown a wider project value discrepancy, which is beyond and above the contingency limit. In addition, the research has found the growing trend in the use

  5. Legislation, standards and methods for mercury emissions control

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2012-04-15

    Mercury is an element of growing global concern. The United Nations Environment Programme plans to finalise and ratify a new global legally-binding convention on mercury by 2013. Canada already has legislation on mercury emissions from coal-fired utilities and the USA has recently released the new Mercury and Air Toxics Standard. Although other countries may not have mercury-specific legislation as such, many have legislation which results in significant co-benefit mercury reduction due to the installation of effective flue-gas cleaning technologies. This report reviews the current situation and trends in mercury emission legislation and, where possible, discusses the actions that will be taken under proposed or impending standards globally and regionally. The report also reviews the methods currently applied for mercury control and for mercury emission measurement with emphasis on the methodologies most appropriate for compliance. Examples of the methods of mercury control currently deployed in the USA, Canada and elsewhere are included.

  6. Standard Test Method for Gel Time of Carbon Fiber-Epoxy Prepreg

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1999-01-01

    1.1 This test method covers the determination of gel time of carbon fiber-epoxy tape and sheet. The test method is suitable for the measurement of gel time of resin systems having either high or low viscosity. 1.2 The values stated in SI units are to be regarded as standard. The values in parentheses are for reference only. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  7. Practical no-gold-standard evaluation framework for quantitative imaging methods: application to lesion segmentation in positron emission tomography.

    Science.gov (United States)

    Jha, Abhinav K; Mena, Esther; Caffo, Brian; Ashrafinia, Saeed; Rahmim, Arman; Frey, Eric; Subramaniam, Rathan M

    2017-01-01

    Recently, a class of no-gold-standard (NGS) techniques have been proposed to evaluate quantitative imaging methods using patient data. These techniques provide figures of merit (FoMs) quantifying the precision of the estimated quantitative value without requiring repeated measurements and without requiring a gold standard. However, applying these techniques to patient data presents several practical difficulties including assessing the underlying assumptions, accounting for patient-sampling-related uncertainty, and assessing the reliability of the estimated FoMs. To address these issues, we propose statistical tests that provide confidence in the underlying assumptions and in the reliability of the estimated FoMs. Furthermore, the NGS technique is integrated within a bootstrap-based methodology to account for patient-sampling-related uncertainty. The developed NGS framework was applied to evaluate four methods for segmenting lesions from F-Fluoro-2-deoxyglucose positron emission tomography images of patients with head-and-neck cancer on the task of precisely measuring the metabolic tumor volume. The NGS technique consistently predicted the same segmentation method as the most precise method. The proposed framework provided confidence in these results, even when gold-standard data were not available. The bootstrap-based methodology indicated improved performance of the NGS technique with larger numbers of patient studies, as was expected, and yielded consistent results as long as data from more than 80 lesions were available for the analysis.

  8. 42 CFR 440.260 - Methods and standards to assure quality of services.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 4 2010-10-01 2010-10-01 false Methods and standards to assure quality of services. 440.260 Section 440.260 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH... and Limits Applicable to All Services § 440.260 Methods and standards to assure quality of services...

  9. Standard test method for calibration of surface/stress measuring devices

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1997-01-01

    Return to Contents page 1.1 This test method covers calibration or verification of calibration, or both, of surface-stress measuring devices used to measure stress in annealed and heat-strengthened or tempered glass using polariscopic or refractometry based principles. 1.2 This test method is nondestructive. 1.3 This test method uses transmitted light, and therefore, is applicable to light-transmitting glasses. 1.4 This test method is not applicable to chemically tempered glass. 1.5 Using the procedure described, surface stresses can be measured only on the “tin” side of float glass. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  10. Radioactive standards and calibration methods for contamination monitoring instruments

    Energy Technology Data Exchange (ETDEWEB)

    Yoshida, Makoto [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    1997-06-01

    Contamination monitoring in the facilities for handling unsealed radioactive materials is one of the most important procedures for radiation protection as well as radiation dose monitoring. For implementation of the proper contamination monitoring, radiation measuring instruments should not only be suitable to the purpose of monitoring, but also be well calibrated for the objective qualities of measurement. In the calibration of contamination monitoring instruments, quality reference activities need to be used. They are supplied in different such as extended sources, radioactive solutions or radioactive gases. These reference activities must be traceable to the national standards or equivalent standards. On the other hand, the appropriate calibration methods must be applied for each type of contamination monitoring instruments. In this paper, the concepts of calibration for contamination monitoring instruments, reference sources, determination methods of reference quantities and practical calibration methods of contamination monitoring instruments, including the procedures carried out in Japan Atomic Energy Research Institute and some relevant experimental data. (G.K.)

  11. Standardization method for alpha and beta surface sources

    Energy Technology Data Exchange (ETDEWEB)

    Sahagia, M; Grigorescu, E L; Razdolescu, A C; Ivan, C [Institute of Physics and Nuclear Engineering, Institute of Atomic Physics, PO Box MG-6, R-76900 Bucharest, (Romania)

    1994-01-01

    The installation and method of standardization of large surface alpha and beta sources are presented. A multiwire, flow-type proportional counter and the associated electronics is used. The counter is placed in a lead-shield. The response of the system in (s[sup -1]/Bq) or (s[sup -1]/(particle x s[sup -1])) was determined for [sup 241] Am, [sup 239] Pu, [sup 147] Pm, [sup 204] Tl, [sup 90](Sr+Y) and [sup 137] Cs using standard sources with different dimensions, from some mm[sup 2] to 180 x 220 mm[sup 2]. The system was legally attested for expanded uncertainties of +7%. (Author).

  12. Evaluation of a Method for Nitrotyrosine Site Identification and Relative Quantitation Using a Stable Isotope-Labeled Nitrated Spike-In Standard and High Resolution Fourier Transform MS and MS/MS Analysis

    Directory of Open Access Journals (Sweden)

    Kent W. Seeley

    2014-04-01

    Full Text Available The overproduction of reactive oxygen and nitrogen species (ROS and RNS can have deleterious effects in the cell, including structural and possible activity-altering modifications to proteins. Peroxynitrite is one such RNS that can result in a specific protein modification, nitration of tyrosine residues to form nitrotyrosine, and to date, the identification of nitrotyrosine sites in proteins continues to be a major analytical challenge. We have developed a method by which 15N-labeled nitrotyrosine groups are generated on peptide or protein standards using stable isotope-labeled peroxynitrite (O15NOO−, and the resulting standard is mixed with representative samples in which nitrotyrosine formation is to be measured by mass spectrometry (MS. Nitropeptide MS/MS spectra are filtered using high mass accuracy Fourier transform MS (FTMS detection of the nitrotyrosine immonium ion. Given that the nitropeptide pair is co-isolated for MS/MS fragmentation, the nitrotyrosine immonium ions (at m/z = 181 or 182 can be used for relative quantitation with negligible isotopic interference at a mass resolution of greater than 50,000 (FWHM, full width at half-maximum. Furthermore, the standard potentially allows for the increased signal of nitrotyrosine-containing peptides, thus facilitating selection for MS/MS in a data-dependent mode of acquisition. We have evaluated the methodology in terms of nitrotyrosine site identification and relative quantitation using nitrated peptide and protein standards.

  13. Vaginismus and dyspareunia : Relationship with general and sex-related moral standards

    NARCIS (Netherlands)

    Borg, Charmaine; de Jong, Peter J.; Schultz, Willibrord Weijmar

    Introduction. Relatively strong adherence to conservative values and/or relatively strict sex-related moral standards logically restricts the sexual repertoire and will lower the threshold for experiencing negative emotions in a sexual context. In turn, this may generate withdrawal and avoidance

  14. Methods of numerical relativity

    International Nuclear Information System (INIS)

    Piran, T.

    1983-01-01

    Numerical Relativity is an alternative to analytical methods for obtaining solutions for Einstein equations. Numerical methods are particularly useful for studying generation of gravitational radiation by potential strong sources. The author reviews the analytical background, the numerical analysis aspects and techniques and some of the difficulties involved in numerical relativity. (Auth.)

  15. Developing content standards for teaching research skills using a delphi method

    NARCIS (Netherlands)

    Schaaf, M.F. van der; Stokking, K.M.; Verloop, N.

    2005-01-01

    The increased attention for teacher assessment and current educational reforms ask for procedures to develop adequate content standards. For the development of content standards on teaching research skills, a Delphi method based on stakeholders’ judgments has been designed and tested. In three

  16. Standard test method for guided bend test for ductility of welds

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2002-01-01

    1.1 This test method covers a guided bend test for the determination of soundness and ductility of welds in ferrous and nonferrous products. Defects, not shown by X rays, may appear in the surface of a specimen when it is subjected to progressive localized overstressing. This guided bend test has been developed primarily for plates and is not intended to be substituted for other methods of bend testing. 1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. Note 1—For additional information see Terminology E 6, and American Welding Society Standard D 1.1. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  17. 77 FR 50757 - Charging Standard Administrative Fees for Nonprogram-Related Information

    Science.gov (United States)

    2012-08-22

    ... are announcing the standardized administrative fees we will charge to recover our full cost of... will ensure fees are consistent and that we collect the full cost of supplying our information when a... standard fees that are calculated to reflect the full cost of providing information for nonprogram-related...

  18. Isolating DNA from sexual assault cases: a comparison of standard methods with a nuclease-based approach

    Science.gov (United States)

    2012-01-01

    Background Profiling sperm DNA present on vaginal swabs taken from rape victims often contributes to identifying and incarcerating rapists. Large amounts of the victim’s epithelial cells contaminate the sperm present on swabs, however, and complicate this process. The standard method for obtaining relatively pure sperm DNA from a vaginal swab is to digest the epithelial cells with Proteinase K in order to solubilize the victim’s DNA, and to then physically separate the soluble DNA from the intact sperm by pelleting the sperm, removing the victim’s fraction, and repeatedly washing the sperm pellet. An alternative approach that does not require washing steps is to digest with Proteinase K, pellet the sperm, remove the victim’s fraction, and then digest the residual victim’s DNA with a nuclease. Methods The nuclease approach has been commercialized in a product, the Erase Sperm Isolation Kit (PTC Labs, Columbia, MO, USA), and five crime laboratories have tested it on semen-spiked female buccal swabs in a direct comparison with their standard methods. Comparisons have also been performed on timed post-coital vaginal swabs and evidence collected from sexual assault cases. Results For the semen-spiked buccal swabs, Erase outperformed the standard methods in all five laboratories and in most cases was able to provide a clean male profile from buccal swabs spiked with only 1,500 sperm. The vaginal swabs taken after consensual sex and the evidence collected from rape victims showed a similar pattern of Erase providing superior profiles. Conclusions In all samples tested, STR profiles of the male DNA fractions obtained with Erase were as good as or better than those obtained using the standard methods. PMID:23211019

  19. ARE METHODS USED TO INTEGRATE STANDARDIZED MANAGEMENT SYSTEMS A CONDITIONING FACTOR OF THE LEVEL OF INTEGRATION? AN EMPIRICAL STUDY

    Directory of Open Access Journals (Sweden)

    Merce Bernardo

    2011-09-01

    Full Text Available Organizations are increasingly implementing multiple Management System Standards (M SSs and considering managing the related Management Systems (MSs as a single system.The aim of this paper is to analyze if methods us ed to integrate standardized MSs condition the level of integration of those MSs. A descriptive methodology has been applied to 343 Spanish organizations registered to, at least, ISO 9001 and ISO 14001. Seven groups of these organizations using different combinations of methods have been analyzed Results show that these organizations have a high level of integration of their MSs. The most common method used, was the process map. Organizations using a combination of different methods achieve higher levels of integration than those using a single method. However, no evidence has been found to confirm the relationship between the method used and the integration level achieved.

  20. The Rhetoric of Arrogance: The Public Relations Response of the Standard Oil Trust.

    Science.gov (United States)

    Boyd, Josh

    2001-01-01

    Illustrates one of the earliest American public relations debacles (ending in the dissolution of the Standard Oil Trust in 1911). Presents background on Standard Oil and offers an overview Ida Tarbell's influential "History of the Standard Oil company." Argues that Standard failed to respond to these accounts adequately, reinforcing…

  1. Standard test method for drop-weight tear tests of ferritic steels

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2003-01-01

    1.1 This test method covers drop-weight tear tests (DWTT) on ferritic steels with thicknesses between 3.18 and 19.1 mm. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  2. The standardization of data relational mode in the materials database for nuclear power engineering

    International Nuclear Information System (INIS)

    Wang Xinxuan

    1996-01-01

    A relational database needs standard data relation ships. The data relation ships include hierarchical structures and repeat set records. Code database is created and the relational database is created between spare parts and materials and properties of the materials. The data relation ships which are not standard are eliminated and all the relation modes are made to meet the demands of the 3NF (Third Norm Form)

  3. A genomic background based method for association analysis in related individuals.

    Directory of Open Access Journals (Sweden)

    Najaf Amin

    Full Text Available BACKGROUND: Feasibility of genotyping of hundreds and thousands of single nucleotide polymorphisms (SNPs in thousands of study subjects have triggered the need for fast, powerful, and reliable methods for genome-wide association analysis. Here we consider a situation when study participants are genetically related (e.g. due to systematic sampling of families or because a study was performed in a genetically isolated population. Of the available methods that account for relatedness, the Measured Genotype (MG approach is considered the 'gold standard'. However, MG is not efficient with respect to time taken for the analysis of genome-wide data. In this context we proposed a fast two-step method called Genome-wide Association using Mixed Model and Regression (GRAMMAR for the analysis of pedigree-based quantitative traits. This method certainly overcomes the drawback of time limitation of the measured genotype (MG approach, but pays in power. One of the major drawbacks of both MG and GRAMMAR, is that they crucially depend on the availability of complete and correct pedigree data, which is rarely available. METHODOLOGY: In this study we first explore type 1 error and relative power of MG, GRAMMAR, and Genomic Control (GC approaches for genetic association analysis. Secondly, we propose an extension to GRAMMAR i.e. GRAMMAR-GC. Finally, we propose application of GRAMMAR-GC using the kinship matrix estimated through genomic marker data, instead of (possibly missing and/or incorrect genealogy. CONCLUSION: Through simulations we show that MG approach maintains high power across a range of heritabilities and possible pedigree structures, and always outperforms other contemporary methods. We also show that the power of our proposed GRAMMAR-GC approaches to that of the 'gold standard' MG for all models and pedigrees studied. We show that this method is both feasible and powerful and has correct type 1 error in the context of genome-wide association analysis

  4. Standardized methods for photography in procedural dermatology using simple equipment.

    Science.gov (United States)

    Hexsel, Doris; Hexsel, Camile L; Dal'Forno, Taciana; Schilling de Souza, Juliana; Silva, Aline F; Siega, Carolina

    2017-04-01

    Photography is an important tool in dermatology. Reproducing the settings of before photos after interventions allows more accurate evaluation of treatment outcomes. In this article, we describe standardized methods and tips to obtain photographs, both for clinical practice and research procedural dermatology, using common equipment. Standards for the studio, cameras, photographer, patients, and framing are presented in this article. © 2017 The International Society of Dermatology.

  5. Rare earths analysis of rock samples by instrumental neutron activation analysis, internal standard method

    International Nuclear Information System (INIS)

    Silachyov, I.

    2016-01-01

    The application of instrumental neutron activation analysis for the determination of long-lived rare earth elements (REE) in rock samples is considered in this work. Two different methods are statistically compared: the well established external standard method carried out using standard reference materials, and the internal standard method (ISM), using Fe, determined through X-ray fluorescence analysis, as an element-comparator. The ISM proved to be the more precise method for a wide range of REE contents and can be recommended for routine practice. (author)

  6. Method and platform standardization in MRM-based quantitative plasma proteomics.

    Science.gov (United States)

    Percy, Andrew J; Chambers, Andrew G; Yang, Juncong; Jackson, Angela M; Domanski, Dominik; Burkhart, Julia; Sickmann, Albert; Borchers, Christoph H

    2013-12-16

    There exists a growing demand in the proteomics community to standardize experimental methods and liquid chromatography-mass spectrometry (LC/MS) platforms in order to enable the acquisition of more precise and accurate quantitative data. This necessity is heightened by the evolving trend of verifying and validating candidate disease biomarkers in complex biofluids, such as blood plasma, through targeted multiple reaction monitoring (MRM)-based approaches with stable isotope-labeled standards (SIS). Considering the lack of performance standards for quantitative plasma proteomics, we previously developed two reference kits to evaluate the MRM with SIS peptide approach using undepleted and non-enriched human plasma. The first kit tests the effectiveness of the LC/MRM-MS platform (kit #1), while the second evaluates the performance of an entire analytical workflow (kit #2). Here, these kits have been refined for practical use and then evaluated through intra- and inter-laboratory testing on 6 common LC/MS platforms. For an identical panel of 22 plasma proteins, similar concentrations were determined, regardless of the kit, instrument platform, and laboratory of analysis. These results demonstrate the value of the kit and reinforce the utility of standardized methods and protocols. The proteomics community needs standardized experimental protocols and quality control methods in order to improve the reproducibility of MS-based quantitative data. This need is heightened by the evolving trend for MRM-based validation of proposed disease biomarkers in complex biofluids such as blood plasma. We have developed two kits to assist in the inter- and intra-laboratory quality control of MRM experiments: the first kit tests the effectiveness of the LC/MRM-MS platform (kit #1), while the second evaluates the performance of an entire analytical workflow (kit #2). In this paper, we report the use of these kits in intra- and inter-laboratory testing on 6 common LC/MS platforms. This

  7. Standard test methods for the strong-base resins used in the recovery of uranium

    International Nuclear Information System (INIS)

    Ford, M.A.; Lombaard, L.R.

    1986-01-01

    There are no detailed specifications for the strong-base ion-exchange resins used in continuous ion-exchange plants, and it was considered that a very useful purpose would be served by the publication of a series of standard laboratory tests on which such specifications could be based. This report describes test methods that are relevant to the ion-exchange recovery of uranium. They include tests of the physical properties of strong-base resins (relative density, particle-size distribution, and moisture content) and of their chemical properties (theoretical capacity, equilibrium capacity, kinetics of loading and elution). Included are several supporting procedures that are used in conjunction with these methods

  8. Development of an analysis rule of diagnosis error for standard method of human reliability analysis

    International Nuclear Information System (INIS)

    Jeong, W. D.; Kang, D. I.; Jeong, K. S.

    2003-01-01

    This paper presents the status of development of Korea standard method for Human Reliability Analysis (HRA), and proposed a standard procedure and rules for the evaluation of diagnosis error probability. The quality of KSNP HRA was evaluated using the requirement of ASME PRA standard guideline, and the design requirement for the standard HRA method was defined. Analysis procedure and rules, developed so far, to analyze diagnosis error probability was suggested as a part of the standard method. And also a study of comprehensive application was performed to evaluate the suitability of the proposed rules

  9. Standard Test Method for Thermal Oxidative Resistance of Carbon Fibers

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1982-01-01

    1.1 This test method covers the apparatus and procedure for the determination of the weight loss of carbon fibers, exposed to ambient hot air, as a means of characterizing their oxidative resistance. 1.2 The values stated in SI units are to be regarded as standard. The values given in parentheses are mathematical conversions to inch-pound units which are provided for information only and are not considered standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific hazard information, see Section 8.

  10. Analytical chemistry methods for boron carbide absorber material. [Standard

    Energy Technology Data Exchange (ETDEWEB)

    DELVIN WL

    1977-07-01

    This standard provides analytical chemistry methods for the analysis of boron carbide powder and pellets for the following: total C and B, B isotopic composition, soluble C and B, fluoride, chloride, metallic impurities, gas content, water, nitrogen, and oxygen. (DLC)

  11. Multiplex cDNA quantification method that facilitates the standardization of gene expression data

    Science.gov (United States)

    Gotoh, Osamu; Murakami, Yasufumi; Suyama, Akira

    2011-01-01

    Microarray-based gene expression measurement is one of the major methods for transcriptome analysis. However, current microarray data are substantially affected by microarray platforms and RNA references because of the microarray method can provide merely the relative amounts of gene expression levels. Therefore, valid comparisons of the microarray data require standardized platforms, internal and/or external controls and complicated normalizations. These requirements impose limitations on the extensive comparison of gene expression data. Here, we report an effective approach to removing the unfavorable limitations by measuring the absolute amounts of gene expression levels on common DNA microarrays. We have developed a multiplex cDNA quantification method called GEP-DEAN (Gene expression profiling by DCN-encoding-based analysis). The method was validated by using chemically synthesized DNA strands of known quantities and cDNA samples prepared from mouse liver, demonstrating that the absolute amounts of cDNA strands were successfully measured with a sensitivity of 18 zmol in a highly multiplexed manner in 7 h. PMID:21415008

  12. Optimization of two methods based on ultrasound energy as alternative to European standards for soluble salts extraction from building materials.

    Science.gov (United States)

    Prieto-Taboada, N; Gómez-Laserna, O; Martinez-Arkarazo, I; Olazabal, M A; Madariaga, J M

    2012-11-01

    The Italian recommendation NORMAL 13/83, later replaced by the UNI 11087/2003 norm, were used as standard for soluble salts extraction from construction materials. These standards are based on long-time stirring (72 and 2h, respectively) of the sample in deionized water. In this work two ultrasound based methods were optimized in order to reduce the extraction time while efficiency is improved. The instrumental variables involved in the extraction assisted by ultrasound bath and focused ultrasounds were optimized by experimental design. As long as it was possible, the same non-instrumental parameters values as those of standard methods were used in order to compare the results obtained on a mortar sample showing a black crust by the standards and the optimized methods. The optimal extraction time for the ultrasounds bath was found to be of two hours. Although the extraction time was equal to the standard UNI 11087/2003, the obtained extraction recovery was improved up to 119%. The focused ultrasound system achieved also better recoveries (up to 106%) depending on the analyte in 1h treatment time. The repeatabilities of the proposed ultrasound based methods were comparables to those of the standards. Therefore, the selection of one or the other of the ultrasound based methods will depend on topics such as laboratory facilities or number of samples, and not in aspects related with their quality parameters. Copyright © 2012 Elsevier B.V. All rights reserved.

  13. Current and future neutron radiography standards

    International Nuclear Information System (INIS)

    Brenizer, J.S.

    1999-01-01

    Only two organizations are actively producing standards which are used in neutron radiology (NR): the American Society of Testing and Materials (ASTM) and the International Organization for Standardization (ISO). Six ASTM standards exist that address the neutron radiography method. Two of the ASTM standards have been extensively used world-wide. ISO has a working group which is developing three standards that also address the neutron radiography method. Two of these are currently making their way through the ISO approval system. No ASTM or ISO standards exist for the neutron radioscopic method. Future ASTM standards will address the neutron radioscopic method and neutron radiologic system characterization. It is expected that similar efforts will be undertaken in ISO. Given the relatively small community providing neutron radiologic services, international cooperation and the need for ISO standards will most likely continue to grow.(author)

  14. Standard test method for determining susceptibility to stress-corrosion cracking of 2XXX and 7XXX Aluminum alloy products

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1998-01-01

    1.1 This test method covers a uniform procedure for characterizing the resistance to stress-corrosion cracking (SCC) of high-strength aluminum alloy wrought products for the guidance of those who perform stress-corrosion tests, for those who prepare stress-corrosion specifications, and for materials engineers. 1.2 This test method covers method of sampling, type of specimen, specimen preparation, test environment, and method of exposure for determining the susceptibility to SCC of 2XXX (with 1.8 to 7.0 % copper) and 7XXX (with 0.4 to 2.8 % copper) aluminum alloy products, particularly when stressed in the short-transverse direction relative to the grain structure. 1.3 The values stated in SI units are to be regarded as standard. The inch-pound units in parentheses are provided for information. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and de...

  15. Archive of Census Related Products (ACRP): 1990 Standard Extract Files

    Data.gov (United States)

    National Aeronautics and Space Administration — The 1990 Standard Extract Files portion of the Archive of Census Related Products (ACRP) contains population and housing data derived from the U.S. Census Bureau's...

  16. Method of making stepped photographic density standards of radiographic photographs

    International Nuclear Information System (INIS)

    Borovin, I.V.; Kondina, M.A.

    1987-01-01

    In industrial radiography practice the need often arises for a prompt evaluation of the photographic density of an x-ray film. A method of making stepped photographic density standards for industrial radiography by contact printing from a negative is described. The method is intended for industrial radiation flaw detection laboratories not having specialized sensitometric equipment

  17. Standard Test Method for Normal Spectral Emittance at Elevated Temperatures

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1972-01-01

    1.1 This test method describes a highly accurate technique for measuring the normal spectral emittance of electrically conducting materials or materials with electrically conducting substrates, in the temperature range from 600 to 1400 K, and at wavelengths from 1 to 35 μm. 1.2 The test method requires expensive equipment and rather elaborate precautions, but produces data that are accurate to within a few percent. It is suitable for research laboratories where the highest precision and accuracy are desired, but is not recommended for routine production or acceptance testing. However, because of its high accuracy this test method can be used as a referee method to be applied to production and acceptance testing in cases of dispute. 1.3 The values stated in SI units are to be regarded as the standard. The values in parentheses are for information only. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this stan...

  18. Analysis of Indonesian educational system standard with KSIM cross-impact method

    Science.gov (United States)

    Arridjal, F.; Aldila, D.; Bustamam, A.

    2017-07-01

    The Result of The Programme of International Student Assessment (PISA) on 2012 shows that Indonesia is on 64'th position from 65 countries in Mathematics Mean Score. The 2013 Learning Curve Mapping, Indonesia is included in the 10th category of countries with the lowest performance on cognitive skills aspect, i.e. 37'th position from 40 countries. Competency is built by 3 aspects, one of them is cognitive aspect. The low result of mapping on cognitive aspect, describe the low of graduate competences as an output of Indonesia National Education System (INES). INES adopting a concept Eight Educational System Standards (EESS), one of them is graduate competency standard which connected directly with Indonesia's students. This research aims is to model INES by using KSIM cross-impact. Linear regression models of EESS constructed using the accreditation national data of Senior High Schools in Indonesia. The results then interpreted as impact value on the construction of KSIM cross-impact INES. The construction is used to analyze the interaction of EESS and doing numerical simulation for possible public policy in the education sector, i.e. stimulate the growth of education staff standard, content, process and infrastructure. All simulations of public policy has been done with 2 methods i.e with a multiplier impact method and with constant intervention method. From numerical simulation result, it is shown that stimulate the growth standard of content in the construction KSIM cross-impact EESS is the best option for public policy to maximize the growth of graduate competency standard.

  19. Cutibacterium acnes molecular typing: time to standardize the method.

    Science.gov (United States)

    Dagnelie, M-A; Khammari, A; Dréno, B; Corvec, S

    2018-03-12

    The Gram-positive, anaerobic/aerotolerant bacterium Cutibacterium acnes is a commensal of healthy human skin; it is subdivided into six main phylogenetic groups or phylotypes: IA1, IA2, IB, IC, II and III. To decipher how far specific subgroups of C. acnes are involved in disease physiopathology, different molecular typing methods have been developed to identify these subgroups: i.e. phylotypes, clonal complexes, and types defined by single-locus sequence typing (SLST). However, as several molecular typing methods have been developed over the last decade, it has become a difficult task to compare the results from one article to another. Based on the scientific literature, the aim of this narrative review is to propose a standardized method to perform molecular typing of C. acnes, according to the degree of resolution needed (phylotypes, clonal complexes, or SLST types). We discuss the existing different typing methods from a critical point of view, emphasizing their advantages and drawbacks, and we identify the most frequently used methods. We propose a consensus algorithm according to the needed phylogeny resolution level. We first propose to use multiplex PCR for phylotype identification, MLST9 for clonal complex determination, and SLST for phylogeny investigation including numerous isolates. There is an obvious need to create a consensus about molecular typing methods for C. acnes. This standardization will facilitate the comparison of results between one article and another, and also the interpretation of clinical data. Copyright © 2018 European Society of Clinical Microbiology and Infectious Diseases. Published by Elsevier Ltd. All rights reserved.

  20. Standard practice for determining relative image quality response of industrial radiographic imaging systems

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2007-01-01

    1.1 This standard provides a practice whereby industrial radiographic imaging systems may be comparatively assessed using the concept of relative image quality response (RIQR). The RIQR method presented within this practice is based upon the use of equivalent penetrameter sensitivity (EPS) described within Practice E 1025 and subsection 5.2 of this practice. Figure 1 illustrates a relative image quality indicator (RIQI) that has four different steel plaque thicknesses (.015, .010, .008, and .005 in.) sequentially positioned (from top to bottom) on a ¾-in. thick steel plate. The four plaques contain a total of 14 different arrays of penetrameter-type hole sizes designed to render varied conditions of threshold visibility ranging from 1.92 % EPS (at the top) to .94 % EPS (at the bottom) when exposed to nominal 200 keV X-ray radiation. Each “EPS” array consists of 30 identical holes; thus, providing the user with a quantity of threshold sensitivity levels suitable for relative image qualitative response com...

  1. Work-related falls among union carpenters in Washington State before and after the Vertical Fall Arrest Standard.

    Science.gov (United States)

    Lipscomb, Hester J; Li, Leiming; Dement, John

    2003-08-01

    Washington State enacted a change in their fall standard for the construction industry in 1991, preceding the Safety Standard for Fall Protection in the Construction Industry promulgated by Federal OSHA in 1994. We evaluated changes in the rate of falls from elevations and measures of severity among a large cohort of union carpenters after the fall standard change in Washington State, taking into account the temporal trends in their overall injury rates. There was a significant decrease in the rate of falls from height after the standard went into effect, even after adjusting for the overall decrease in work-related injuries among this cohort. Much of the decrease was immediate, likely representing the publicity surrounding fatal falls and subsequent promulgation of the standard. The greatest decrease was seen between 3 and 3(1/2) years after the standard went into effect. There was a significant reduction in mean paid lost days per event after the standard change and there was a significant reduction in mean cost per fall when adjusting for age and the temporal trend for costs among non-fall injuries. Through the use of observational methods we have demonstrated significant effects of the Washington State Vertical Fall Arrest Standard among carpenters in the absence of a control or comparison group. Without controlling for the temporal trend in overall injury rates, the rate of decline in falls appeared significantly greater, but the more pronounced, but delayed, decline was not seen. The analyses demonstrate potential error in failing to account for temporal patterns or assuming that a decline after an intervention is related to the intervention. Copyright 2003 Wiley-Liss, Inc.

  2. Primary activity standardization of {sup 57}Co by sum-peak method

    Energy Technology Data Exchange (ETDEWEB)

    Iwahara, A. [Laboratorio Nacional de Metrologia das Radiacoes Ionizantes (LNMRI)/Instituto de Radioprotecao e Dosimetria (IRD)/Comissao Nacional de Energia Nuclear - CNEN, Av. Salvador Allende, s/no. Recreio dos Bandeirantes - CEP 22780-160 Rio de Janeiro (Brazil)], E-mail: iwahara@ird.gov.br; Poledna, R.; Silva, C.J. da; Tauhata, L. [Laboratorio Nacional de Metrologia das Radiacoes Ionizantes (LNMRI)/Instituto de Radioprotecao e Dosimetria (IRD)/Comissao Nacional de Energia Nuclear - CNEN, Av. Salvador Allende, s/no. Recreio dos Bandeirantes - CEP 22780-160 Rio de Janeiro (Brazil)

    2009-10-15

    The sum-peak method was applied to standardize a {sup 57}Co solution within the framework of an international comparison organized by International Atomic Energy Agency, in 2008, aimed toward international traceability of activity measurements. A planar germanium detector was used with the sources placed on top of the detector for activity determination measurements. An analytical expression for accidental summing correction was derived and the effect of the germanium characteristic KX-ray escape peak of 112 keV was taken into account. The standard uncertainty associated to the activity concentration value was 0.37% and the result was compared with other measurement methods.

  3. Development and validation of new spectrophotometric ratio H-point standard addition method and application to gastrointestinal acting drugs mixtures

    Science.gov (United States)

    Yehia, Ali M.

    2013-05-01

    New, simple, specific, accurate and precise spectrophotometric technique utilizing ratio spectra is developed for simultaneous determination of two different binary mixtures. The developed ratio H-point standard addition method (RHPSAM) was managed successfully to resolve the spectral overlap in itopride hydrochloride (ITO) and pantoprazole sodium (PAN) binary mixture, as well as, mosapride citrate (MOS) and PAN binary mixture. The theoretical background and advantages of the newly proposed method are presented. The calibration curves are linear over the concentration range of 5-60 μg/mL, 5-40 μg/mL and 4-24 μg/mL for ITO, MOS and PAN, respectively. Specificity of the method was investigated and relative standard deviations were less than 1.5. The accuracy, precision and repeatability were also investigated for the proposed method according to ICH guidelines.

  4. The standard deviation method: data analysis by classical means and by neural networks

    International Nuclear Information System (INIS)

    Bugmann, G.; Stockar, U. von; Lister, J.B.

    1989-08-01

    The Standard Deviation Method is a method for determining particle size which can be used, for instance, to determine air-bubble sizes in a fermentation bio-reactor. The transmission coefficient of an ultrasound beam through a gassy liquid is measured repetitively. Due to the displacements and random positions of the bubbles, the measurements show a scatter whose standard deviation is dependent on the bubble-size. The precise relationship between the measured standard deviation, the transmission and the particle size has been obtained from a set of computer-simulated data. (author) 9 figs., 5 refs

  5. Robust steganographic method utilizing properties of MJPEG compression standard

    Directory of Open Access Journals (Sweden)

    Jakub Oravec

    2015-06-01

    Full Text Available This article presents design of steganographic method, which uses video container as cover data. Video track was recorded by webcam and was further encoded by compression standard MJPEG. Proposed method also takes in account effects of lossy compression. The embedding process is realized by switching places of transform coefficients, which are computed by Discrete Cosine Transform. The article contains possibilities, used techniques, advantages and drawbacks of chosen solution. The results are presented at the end of the article.

  6. Orthogonal analytical methods for botanical standardization: determination of green tea catechins by qNMR and LC-MS/MS.

    Science.gov (United States)

    Napolitano, José G; Gödecke, Tanja; Lankin, David C; Jaki, Birgit U; McAlpine, James B; Chen, Shao-Nong; Pauli, Guido F

    2014-05-01

    The development of analytical methods for parallel characterization of multiple phytoconstituents is essential to advance the quality control of herbal products. While chemical standardization is commonly carried out by targeted analysis using gas or liquid chromatography-based methods, more universal approaches based on quantitative (1)H NMR (qHNMR) measurements are being used increasingly in the multi-targeted assessment of these complex mixtures. The present study describes the development of a 1D qHNMR-based method for simultaneous identification and quantification of green tea constituents. This approach utilizes computer-assisted (1)H iterative Full Spin Analysis (HiFSA) and enables rapid profiling of seven catechins in commercial green tea extracts. The qHNMR results were cross-validated against quantitative profiles obtained with an orthogonal LC-MS/MS method. The relative strengths and weaknesses of both approaches are discussed, with special emphasis on the role of identical reference standards in qualitative and quantitative analyses. Copyright © 2013 Elsevier B.V. All rights reserved.

  7. Relative conservatisms of combination methods used in response spectrum analyses of nuclear piping systems

    International Nuclear Information System (INIS)

    Gupta, S.; Kustu, O.; Jhaveri, D.P.; Blume, J.A.

    1983-01-01

    The paper presents the conclusions of a comprehensive study that investigated the relative conservatisms represented by various combination techniques. Two approaches were taken for the study, producing mutually consistent results. In the first, 20 representative nuclear piping systems were systematically analyzed using the response spectrum method. The total response was obtained using nine different combination methods. One procedure, using the SRSS method for combining spatial components of response and the 10% method for combining the responses of different modes (which is currently acceptable to the U.S. NRC), was the standard for comparison. Responses computed by the other methods were normalized to this standard method. These response ratios were then used to develop cumulative frequency-distribution curves, which were used to establish the relative conservatism of the methods in a probabilistic sense. In the second approach, 30 single-degree-of-freedom (SDOF) systems that represent different modes of hypothetical piping systems and have natural frequencies varying from 1 Hz to 30 Hz, were analyzed for 276 sets of three-component recorded ground motion. A set of hypothetical systems assuming a variety of modes and frequency ranges was developed. The responses of these systems were computed from the responses of the SDOF systems by combining the spatial response components by algebraic summation and the individual mode responses by the Navy method, or combining both spatial and modal response components using the SRSS method. Probability density functions and cumulative distribution functions were developed for the ratio of the responses obtained by both methods. (orig./HP)

  8. Standard test method for radiochemical determination of uranium isotopes in urine by alpha spectrometry

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2011-01-01

    1.1 This test method is applicable to the determination of uranium in urine at levels of detection dependent on sample size, count time, detector background, and tracer yield. It is designed as a screening tool for detection of possible exposure of occupational workers. 1.2 This test method is designed for 50 mL of urine. This test method does not address the sampling protocol or sample preservation methods associated with its use. 1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  9. Present status of standards relating to radiation control and protection

    International Nuclear Information System (INIS)

    Minami, Kentaro

    1996-01-01

    Japanese and international standards related to radiation control and radiation protective management are presented focusing on the forming condition, significance, current situation, and their relationship. Japanese Industrial Standards (JIS) is quite useful in the field of atomic energy as well as other fields in terms of optimization and rationalization of the management. JIS includes JIS Z 4001 Atomic Energy Terminology which corresponds to internationl standards ISO 921 Nuclear Glossary, and JIS Z 4005 Medical Radiation Terminology, covering about 500 articles, which corresponds to IEC 788 Medical Radiology-Terminology. The first standards regarding radiation protection was established in X-ray Film Badge, which is included in the field of personal dosimeter, in 1956. Currently, 36 JIS has been established in the field of radiation management dosimeter and 3 are under arrangement. As for radiation protective supplies, 9 JIS has been established so far. Before proposal of JIS, investigation had been conducted to improve, simplify, and standardize the standards of radiation dosimetric technique, dosimeters, dosimetric procedures, and improvement. In this article, the results of material surface contamination monitoring and body surface monitoring conducted in Atomic Energy Safety Association and Radiation Dosimetry Associationare reported, and ISO and IEC are also treated. (S.Y.)

  10. Standard test method for determining atmospheric chloride deposition rate by wet candle method

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2002-01-01

    1.1 This test method covers a wet candle device and its use in measuring atmospheric chloride deposition (amount of chloride salts deposited from the atmosphere on a given area per unit time). 1.2 Data on atmospheric chloride deposition can be useful in classifying the corrosivity of a specific area, such as an atmospheric test site. Caution must be exercised, however, to take into consideration the season because airborne chlorides vary widely between seasons. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  11. A Mapmark method of standard setting as implemented for the National Assessment Governing Board.

    Science.gov (United States)

    Schulz, E Matthew; Mitzel, Howard C

    2011-01-01

    This article describes a Mapmark standard setting procedure, developed under contract with the National Assessment Governing Board (NAGB). The procedure enhances the bookmark method with spatially representative item maps, holistic feedback, and an emphasis on independent judgment. A rationale for these enhancements, and the bookmark method, is presented, followed by a detailed description of the materials and procedures used in a meeting to set standards for the 2005 National Assessment of Educational Progress (NAEP) in Grade 12 mathematics. The use of difficulty-ordered content domains to provide holistic feedback is a particularly novel feature of the method. Process evaluation results comparing Mapmark to Anghoff-based methods previously used for NAEP standard setting are also presented.

  12. Validation of the k0 standardization method in neutron activation analysis

    International Nuclear Information System (INIS)

    Kubesova, Marie

    2009-01-01

    The goal of this work was to validate the k 0 standardization method in neutron activation analysis for use by the Nuclear Physics Institute's NAA Laboratory. The precision and accuracy of the method were examined by using two types of reference materials: the one type comprised a set of synthetic materials and served to check the implementation of k 0 standardization, the other type consisted of matrix NIST SRMs comprising various different matrices. In general, a good agreement was obtained between the results of this work and the certified values, giving evidence of the accuracy of our results. In addition, the limits were evaluated for 61 elements

  13. Standard Test Method for Solar Transmittance (Terrestrial) of Sheet Materials Using Sunlight

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1986-01-01

    1.1 This test method covers the measurement of solar transmittance (terrestrial) of materials in sheet form by using a pyranometer, an enclosure, and the sun as the energy source. 1.2 This test method also allows measurement of solar transmittance at angles other than normal incidence. 1.3 This test method is applicable to sheet materials that are transparent, translucent, textured, or patterned. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  14. Standard Test Method for Bond Strength of Ceramic Tile to Portland Cement Paste

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2002-01-01

    1.1 This test method covers the determination of the ability of glazed ceramic wall tile, ceramic mosaic tile, quarry tile, and pavers to be bonded to portland cement paste. This test method includes both face-mounted and back-mounted tile. 1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  15. ANSI/ASHRAE/IES Standard 90.1-2016 Performance Rating Method Reference Manual

    Energy Technology Data Exchange (ETDEWEB)

    Goel, Supriya [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Rosenberg, Michael I. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Eley, Charles [Eley and Associates, Hobe Sound, FL (United States)

    2017-09-29

    This document is intended to be a reference manual for the Appendix G Performance Rating Method (PRM) of ANSI/ASHRAE/IES Standard 90.1-2016 (Standard 90.1-2016). The PRM can be used to demonstrate compliance with the standard and to rate the energy efficiency of commercial and high-rise residential buildings with designs that exceed the requirements of Standard 90.1. Use of the PRM for demonstrating compliance with Standard 90.1 is a new feature of the 2016 edition. The procedures and processes described in this manual are designed to provide consistency and accuracy by filling in gaps and providing additional details needed by users of the PRM.

  16. The measurement of magnetic properties of electrical sheet steel - survey on methods and situation of standards

    CERN Document Server

    Sievert, J

    2000-01-01

    A brief review of the different requirements for magnetic measurement techniques for material research, modelling of material properties and grading of the electrical sheet steel for trade purposes is presented. In relation to the main application of laminated electrical steel, this paper deals with AC measurement techniques. Two standard methods, Epstein frame and Single Sheet Tester (SST), producing different results, are used in parallel. This dilemma was analysed in detail. The study leads to a possible solution of the problem, i.e. the possibility of converting the results of one of the two methods into the results of the other in order to satisfy the users of the Epstein method and, at the same time, to improve the acceptance of the more economical SST method.

  17. Standard Test Method for Solar Photometric Transmittance of Sheet Materials Using Sunlight

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1996-01-01

    1.1 This test method covers the measurement of solar photometric transmittance of materials in sheet form. Solar photometric transmittance is measured using a photometer (illuminance meter) in an enclosure with the sun and sky as the source of radiation. The enclosure and method of test is specified in Test Method E 1175 (or Test Method E 1084). 1.2 The purpose of this test method is to specify a photometric sensor to be used with the procedure for measuring the solar photometric transmittance of sheet materials containing inhomogeneities in their optical properties. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  18. Technology transfer through a network of standard methods and recommended practices - The case of petrochemicals

    Science.gov (United States)

    Batzias, Dimitris F.; Karvounis, Sotirios

    2012-12-01

    Technology transfer may take place in parallel with cooperative action between companies participating in the same organizational scheme or using one another as subcontractor (outsourcing). In this case, cooperation should be realized by means of Standard Methods and Recommended Practices (SRPs) to achieve (i) quality of intermediate/final products according to specifications and (ii) industrial process control as required to guarantee such quality with minimum deviation (corresponding to maximum reliability) from preset mean values of representative quality parameters. This work deals with the design of the network of SRPs needed in each case for successful cooperation, implying also the corresponding technology transfer, effectuated through a methodological framework developed in the form of an algorithmic procedure with 20 activity stages and 8 decision nodes. The functionality of this methodology is proved by presenting the path leading from (and relating) a standard test method for toluene, as petrochemical feedstock in the toluene diisocyanate production, to the (6 generations distance upstream) performance evaluation of industrial process control systems (ie., from ASTM D5606 to BS EN 61003-1:2004 in the SRPs network).

  19. Standardized Method for High-throughput Sterilization of Arabidopsis Seeds.

    Science.gov (United States)

    Lindsey, Benson E; Rivero, Luz; Calhoun, Chistopher S; Grotewold, Erich; Brkljacic, Jelena

    2017-10-17

    Arabidopsis thaliana (Arabidopsis) seedlings often need to be grown on sterile media. This requires prior seed sterilization to prevent the growth of microbial contaminants present on the seed surface. Currently, Arabidopsis seeds are sterilized using two distinct sterilization techniques in conditions that differ slightly between labs and have not been standardized, often resulting in only partially effective sterilization or in excessive seed mortality. Most of these methods are also not easily scalable to a large number of seed lines of diverse genotypes. As technologies for high-throughput analysis of Arabidopsis continue to proliferate, standardized techniques for sterilizing large numbers of seeds of different genotypes are becoming essential for conducting these types of experiments. The response of a number of Arabidopsis lines to two different sterilization techniques was evaluated based on seed germination rate and the level of seed contamination with microbes and other pathogens. The treatments included different concentrations of sterilizing agents and times of exposure, combined to determine optimal conditions for Arabidopsis seed sterilization. Optimized protocols have been developed for two different sterilization methods: bleach (liquid-phase) and chlorine (Cl2) gas (vapor-phase), both resulting in high seed germination rates and minimal microbial contamination. The utility of these protocols was illustrated through the testing of both wild type and mutant seeds with a range of germination potentials. Our results show that seeds can be effectively sterilized using either method without excessive seed mortality, although detrimental effects of sterilization were observed for seeds with lower than optimal germination potential. In addition, an equation was developed to enable researchers to apply the standardized chlorine gas sterilization conditions to airtight containers of different sizes. The protocols described here allow easy, efficient, and

  20. 40 CFR 1043.50 - Approval of methods to meet Tier 1 retrofit NOX standards.

    Science.gov (United States)

    2010-07-01

    ... retrofit NOX standards. 1043.50 Section 1043.50 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... SUBJECT TO THE MARPOL PROTOCOL § 1043.50 Approval of methods to meet Tier 1 retrofit NOX standards. Regulation 13 of Annex VI provides for certification of Approved Methods, which are retrofit procedures that...

  1. Implementation of sum-peak method for standardization of positron emission radionuclides

    International Nuclear Information System (INIS)

    Fragoso, Maria da Conceicao de Farias; Oliveira, Mercia Liane de; Lima, Fernando Roberto de Andrade

    2015-01-01

    Positron Emission Tomography (PET) is being increasingly recognized as an important quantitative imaging tool for diagnosis and assessing response to therapy. As correct dose administration plays a crucial part in nuclear medicine, it is important that the instruments used to assay the activity of the short-lived radionuclides are calibrated accurately, with traceability to the national or international standards. The sum-peak method has been widely used for radionuclide standardization. The purpose of this study was to implement the methodology for standardization of PET radiopharmaceuticals at the Regional Center for Nuclear Sciences of the Northeast (CRCN-NE). (author)

  2. Standard Test Method for Resin Flow of Carbon Fiber-Epoxy Prepreg

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1999-01-01

    1.1 This test method covers the determination of the amount of resin flow that will take place from prepreg tape or sheet under given conditions of temperature and pressure. 1.2 The values stated in SI units are to be regarded as standard. The values in parentheses are for reference only. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  3. Standard test method for radiochemical determination of plutonium in Soil by alpha spectroscopy

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2011-01-01

    1.1 This test method covers the determination of plutonium in soils at levels of detection dependent on count time, sample size, detector, background, and tracer yield. This test method describes one acceptable approach to the determination of plutonium in soil. 1.2 This test method is designed for 10 g of soil, previously collected and treated as described in Practices C998 and C999, but sample sizes up to 50 g may be analyzed by this test method. This test method may not be able to completely dissolve all forms of plutonium in the soil matrix. 1.3 The values stated in SI units are to be regarded as standard. The values given in parentheses are for information only. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific hazard statements are given in Section 9.

  4. Standardization in smart grids. Introduction to IT-related methodologies, architectures and standards

    Energy Technology Data Exchange (ETDEWEB)

    Uslar, Mathias; Specht, Michael; Daenekas, Christian; Trefke, Joern; Rohjans, Sebastian; Gonzalez, Jose M.; Rosinger, Christine; Bleiker, Robert [OFFIS - Institut fuer Informatik, Oldenburg (Germany)

    2013-03-01

    Introduction to Standardization for Smart Grids. Presents a tutorial and best practice of Smart Grid Prototype Projects. Written by leading experts in the field. Besides the regulatory and market aspects, the technical level dealing with the knowledge from multiple disciplines and the aspects of technical system integration to achieve interoperability and integration has been a strong focus in the Smart Grid. This topic is typically covered by the means of using (technical) standards for processes, data models, functions and communication links. Standardization is a key issue for Smart Grids due to the involvement of many different sectors along the value chain from the generation to the appliances. The scope of Smart Grid is broad, therefore, the standards landscape is unfortunately very large and complex. This is why the three European Standards Organizations ETSI, CEN and CENELEC created a so called Joint Working Group (JWG). This was the first harmonized effort in Europe to bring together the needed disciplines and experts delivering the final report in May 2011. After this approach proved useful, the Commission used the Mandate M/490: Standardization Mandate to European Standardization Organizations (ESOs) to support European Smart Grid deployment. The focal point addressing the ESO's response to M/490 will be the CEN, CENELEC and ETSI Smart Grids Coordination Group (SG-CG). Based on this mandate, meaningful standardization of architectures, use cases, communication technologies, data models and security standards takes place in the four existing working groups. This book provides an overview on the various building blocks and standards identified as the most prominent ones by the JWG report as well as by the first set of standards group - IEC 61850 and CIM, IEC PAS 62559 for documenting Smart Grid use cases, security requirements from the SGIS groups and an introduction on how to apply the Smart Grid Architecture Model SGAM for utilities. In addition

  5. The Potts models and flows. III, standard and subgraph break-collapse methods

    International Nuclear Information System (INIS)

    Magalhaes, A.C.N. de; Essam, J.W.

    1987-01-01

    An algorithm is developed for the exact calculation of the many spin correlation functions of Potts model clusters which is more efficient than the standard break-collapse method traditionally used in real space renormalization group calculations. The improved performance is based on a relationship which, at any stage of the calculation, allows the replacement of certain subgraphs by single effective edges. Our method avoids, as in the standard one, the time consuming summation over spin states and can be very useful in series expansions and real space renormalisation group calculations on crystal lattices. (Author) [pt

  6. Economic competitiveness gap related to the application of the GAEC standards of cross-compliance on farms: evaluation methodology

    Directory of Open Access Journals (Sweden)

    Marco Fedrizzi

    2015-12-01

    Full Text Available This paper describes the methods used in the monitoring carried out in the farms of the MO.NA.CO. project, to calculate the economic competitiveness gap faced by agricultural holdings that accede to the commitments imposed by the standards included in the project. The monitoring works were performed in agricultural holdings in relation to the particular reference condition of each standard. The processing of the information acquired allowed us to define the working times of each cultivation operation by means of the indications in the recommendations of the Associazione Italiana di Genio Rurale - Italian Rural Engineering Association, that considers the official methodology of the International Commission of the Organisation Scientifique du Travail en Agriculture (C.I.O.S.T.A.. The overall costs and revenues in case of compliance or non-compliance with the commitments of the standard were calculated by using Biondi’s methodology and other norms that indicate the technical and economic coefficients to be used in the calculations (EP 496.2 and D 497.4 ASAE standards. With the data related to the unit cost of ploughing a model Partial Least Squares (PLS has been achieved and validated, and it makes possible to predict the unit cost of this agricultural operation. Finally, the values of the variation of the economic competitiveness gap are reported for each standard.

  7. Standard Reference Test Method for Making Potentiostatic and Potentiodynamic Anodic Polarization Measurements

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2004-01-01

    1.1 This test method covers an experimental procedure for checking experimental technique and instrumentation. If followed, this test method will provide repeatable potentiostatic and potentiodynamic anodic polarization measurements that will reproduce data determined by others at other times and in other laboratories provided all laboratories are testing reference samples from the same lot of Type 430 stainless steel. 1.2 Values stated in SI units are to be regarded as the standard. Inch-pound units given in parentheses are for information only. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  8. Standard Test Method for Measuring Heat Flux Using a Water-Cooled Calorimeter

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2005-01-01

    1.1 This test method covers the measurement of a steady heat flux to a given water-cooled surface by means of a system energy balance. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  9. Standard-Setting Methods as Measurement Processes

    Science.gov (United States)

    Nichols, Paul; Twing, Jon; Mueller, Canda D.; O'Malley, Kimberly

    2010-01-01

    Some writers in the measurement literature have been skeptical of the meaningfulness of achievement standards and described the standard-setting process as blatantly arbitrary. We argue that standard setting is more appropriately conceived of as a measurement process similar to student assessment. The construct being measured is the panelists'…

  10. Standard test methods for pitting and crevice corrosion resistance of stainless steels and related alloys by use of ferric Chloride solution

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2003-01-01

    1.1 These test methods cover procedures for the determination of the resistance of stainless steels and related alloys to pitting and crevice corrosion (see Terminology G 15) when exposed to oxidizing chloride environments. Six procedures are described and identified as Methods A, B, C, D, E, and F. 1.1.1 Method A—Ferric chloride pitting test. 1.1.2 Method B—Ferric chloride crevice test. 1.1.3 Method C—Critical pitting temperature test for nickel-base and chromium-bearing alloys. 1.1.4 Method D—Critical crevice temperature test for nickel-base and chromium-bearing alloys. 1.1.5 Method E—Critical pitting temperature test for stainless steels. 1.1.6 Method F—Critical crevice temperature test for stainless steels. 1.2 Method A is designed to determine the relative pitting resistance of stainless steels and nickel-base, chromium-bearing alloys, whereas Method B can be used for determining both the pitting and crevice corrosion resistance of these alloys. Methods C, D, E and F allow for a rankin...

  11. Calibration of Flick standards

    International Nuclear Information System (INIS)

    Thalmann, Ruedi; Spiller, Jürg; Küng, Alain; Jusko, Otto

    2012-01-01

    Flick standards or magnification standards are widely used for an efficient and functional calibration of the sensitivity of form measuring instruments. The results of a recent measurement comparison have shown to be partially unsatisfactory and revealed problems related to the calibration of these standards. In this paper the influence factors for the calibration of Flick standards using roundness measurement instruments are discussed in detail, in particular the bandwidth of the measurement chain, residual form errors of the device under test, profile distortions due to the diameter of the probing element and questions related to the definition of the measurand. The different contributions are estimated using simulations and are experimentally verified. Also alternative methods to calibrate Flick standards are investigated. Finally the practical limitations of Flick standard calibration are shown and the usability of Flick standards both to calibrate the sensitivity of roundness instruments and to check the filter function of such instruments is analysed. (paper)

  12. Addressing Next Generation Science Standards: A Method for Supporting Classroom Teachers

    Science.gov (United States)

    Pellien, Tamara; Rothenburger, Lisa

    2014-01-01

    The Next Generation Science Standards (NGSS) will define science education for the foreseeable future, yet many educators struggle to see the bridge between current practice and future practices. The inquiry-based methods used by Extension professionals (Kress, 2006) can serve as a guide for classroom educators. Described herein is a method of…

  13. Standardization of Tc-99 by three liquid scintillation counting methods

    International Nuclear Information System (INIS)

    Wyngaardt, W.M. van; Staden, M.J. van; Lubbe, J.; Simpson, B.R.S.

    2014-01-01

    The NMISA participated in the international key comparison of the pure beta-emitter Technetium-99, CCRI(II)-K2.Tc-99. The comparison solution was standardized using three methods, namely the TDCR efficiency calculation method, the CIEMAT/NIST efficiency tracing method and the 4π(LS)β–γ coincidence tracing method with Co-60 as tracer. Excellent agreement between results obtained with the three methods confirmed the applicability of the beta spectral shape given by the latest (2011) DDEP evaluation of Tc-99 decay data, rather than the earlier (2004) evaluation. - Highlights: • Activity concentration of Tc-99 solution measured using three LSC methods. • Methods used are TDCR, CNET and 4π(LS)β–γ coincidence tracing. • Beta spectral shape confirmed by agreement between three methods

  14. Standard test method for tension testing of structural alloys in liquid helium

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This test method describes procedures for the tension testing of structural alloys in liquid helium. The format is similar to that of other ASTM tension test standards, but the contents include modifications for cryogenic testing which requires special apparatus, smaller specimens, and concern for serrated yielding, adiabatic heating, and strain-rate effects. 1.2 To conduct a tension test by this standard, the specimen in a cryostat is fully submerged in normal liquid helium (He I) and tested using crosshead displacement control at a nominal strain rate of 10−3 s−1 or less. Tests using force control or high strain rates are not considered. 1.3 This standard specifies methods for the measurement of yield strength, tensile strength, elongation, and reduction of area. The determination of the elastic modulus is treated in Test Method E 111. Note 1—The boiling point of normal liquid helium (He I) at sea level is 4.2 K (−269°C or −452.1°F or 7.6°R). It decreases with geographic elevation and is...

  15. Standard test method for measurement of corrosion potentials of Aluminum alloys

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1997-01-01

    1.1 This test method covers a procedure for measurement of the corrosion potential (see Note 1) of an aluminum alloy in an aqueous solution of sodium chloride with enough hydrogen peroxide added to provide an ample supply of cathodic reactant. Note 1—The corrosion potential is sometimes referred to as the open-circuit solution or rest potential. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  16. Validation of a search strategy to identify nutrition trials in PubMed using the relative recall method.

    Science.gov (United States)

    Durão, Solange; Kredo, Tamara; Volmink, Jimmy

    2015-06-01

    To develop, assess, and maximize the sensitivity of a search strategy to identify diet and nutrition trials in PubMed using relative recall. We developed a search strategy to identify diet and nutrition trials in PubMed. We then constructed a gold standard reference set to validate the identified trials using the relative recall method. Relative recall was calculated by dividing the number of references from the gold standard our search strategy identified by the total number of references in the gold standard. Our gold standard comprised 298 trials, derived from 16 included systematic reviews. The initial search strategy identified 242 of 298 references, with a relative recall of 81.2% [95% confidence interval (CI): 76.3%, 85.5%]. We analyzed titles and abstracts of the 56 missed references for possible additional terms. We then modified the search strategy accordingly. The relative recall of the final search strategy was 88.6% (95% CI: 84.4%, 91.9%). We developed a search strategy to identify diet and nutrition trials in PubMed with a high relative recall (sensitivity). This could be useful for establishing a nutrition trials register to support the conduct of future research, including systematic reviews. Copyright © 2015 The Authors. Published by Elsevier Inc. All rights reserved.

  17. Comparison of two standardized methods of methacholine inhalation challenge in young adults

    DEFF Research Database (Denmark)

    Siersted, H C; Walker, C M; O'Shaughnessy, A D

    2000-01-01

    In the European Community Respiratory Health Study (ECRHS), airway responsiveness to methacholine was determined using the Mefar dosimeter protocol. Elsewhere, the 2-min tidal breathing method has become the preferred standardized method. The relationship between measurements of responsiveness by...

  18. Standard test method for distribution coefficients of inorganic species by the batch method

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This test method covers the determination of distribution coefficients of chemical species to quantify uptake onto solid materials by a batch sorption technique. It is a laboratory method primarily intended to assess sorption of dissolved ionic species subject to migration through pores and interstices of site specific geomedia. It may also be applied to other materials such as manufactured adsorption media and construction materials. Application of the results to long-term field behavior is not addressed in this method. Distribution coefficients for radionuclides in selected geomedia are commonly determined for the purpose of assessing potential migratory behavior of contaminants in the subsurface of contaminated sites and waste disposal facilities. This test method is also applicable to studies for parametric studies of the variables and mechanisms which contribute to the measured distribution coefficient. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement a...

  19. Standard methods for rearing and selection of Apis mellifera queens

    DEFF Research Database (Denmark)

    Büchler, Ralph; Andonov, Sreten; Bienefeld, Kaspar

    2013-01-01

    Here we cover a wide range of methods currently in use and recommended in modern queen rearing, selection and breeding. The recommendations are meant to equally serve as standards for both scientific and practical beekeeping purposes. The basic conditions and different management techniques for q...

  20. Technical Review of Law Enforcement Standards and Guides Relative to Incident Management

    Energy Technology Data Exchange (ETDEWEB)

    Stenner, Robert D.; Salter, R.; Stanton, J. R.; Fisher, D.

    2009-03-24

    In an effort to locate potential law enforcement-related standards that support incident management, a team from the Pacific Northwest National Laboratory (PNNL) contacted representatives from the National Institute of Standards-Office of Law Enforcement Standards (NIST-OLES), National Institute of Justice (NIJ), Federal Bureau of Investigation (FBI), Secret Service, ASTM International committees that have a law enforcement focus, and a variety of individuals from local and regional law enforcement organizations. Discussions were held with various state and local law enforcement organizations. The NIJ has published several specific equipment-related law enforcement standards that were included in the review, but it appears that law enforcement program and process-type standards are developed principally by organizations that operate at the state and local level. Input is provided from state regulations and codes and from external non-government organizations (NGOs) that provide national standards. The standards that are adopted from external organizations or developed independently by state authorities are available for use by local law enforcement agencies on a voluntary basis. The extent to which they are used depends on the respective jurisdictions involved. In some instances, use of state and local disseminated standards is mandatory, but in most cases, use is voluntary. Usually, the extent to which these standards are used appears to depend on whether or not jurisdictions receive certification from a “governing” entity due to their use and compliance with the standards. In some cases, these certification-based standards are used in principal but without certification or other compliance monitoring. In general, these standards appear to be routinely used for qualification, selection for employment, and training. In these standards, the term “Peace Officer” is frequently used to refer to law enforcement personnel. This technical review of national law

  1. Standardizing operational vector sampling techniques for measuring malaria transmission intensity: evaluation of six mosquito collection methods in western Kenya.

    Science.gov (United States)

    Wong, Jacklyn; Bayoh, Nabie; Olang, George; Killeen, Gerry F; Hamel, Mary J; Vulule, John M; Gimnig, John E

    2013-04-30

    Operational vector sampling methods lack standardization, making quantitative comparisons of malaria transmission across different settings difficult. Human landing catch (HLC) is considered the research gold standard for measuring human-mosquito contact, but is unsuitable for large-scale sampling. This study assessed mosquito catch rates of CDC light trap (CDC-LT), Ifakara tent trap (ITT), window exit trap (WET), pot resting trap (PRT), and box resting trap (BRT) relative to HLC in western Kenya to 1) identify appropriate methods for operational sampling in this region, and 2) contribute to a larger, overarching project comparing standardized evaluations of vector trapping methods across multiple countries. Mosquitoes were collected from June to July 2009 in four districts: Rarieda, Kisumu West, Nyando, and Rachuonyo. In each district, all trapping methods were rotated 10 times through three houses in a 3 × 3 Latin Square design. Anophelines were identified by morphology and females classified as fed or non-fed. Anopheles gambiae s.l. were further identified as Anopheles gambiae s.s. or Anopheles arabiensis by PCR. Relative catch rates were estimated by negative binomial regression. When data were pooled across all four districts, catch rates (relative to HLC indoor) for An. gambiae s.l (95.6% An. arabiensis, 4.4% An. gambiae s.s) were high for HLC outdoor (RR = 1.01), CDC-LT (RR = 1.18), and ITT (RR = 1.39); moderate for WET (RR = 0.52) and PRT outdoor (RR = 0.32); and low for all remaining types of resting traps (PRT indoor, BRT indoor, and BRT outdoor; RR < 0.08 for all). For Anopheles funestus, relative catch rates were high for ITT (RR = 1.21); moderate for HLC outdoor (RR = 0.47), CDC-LT (RR = 0.69), and WET (RR = 0.49); and low for all resting traps (RR < 0.02 for all). At finer geographic scales, however, efficacy of each trap type varied from district to district. ITT, CDC-LT, and WET appear to be effective methods for large-scale vector sampling in

  2. Standardization of Nanoparticle Characterization: Methods for Testing Properties, Stability, and Functionality of Edible Nanoparticles.

    Science.gov (United States)

    McClements, Jake; McClements, David Julian

    2016-06-10

    There has been a rapid increase in the fabrication of various kinds of edible nanoparticles for oral delivery of bioactive agents, such as those constructed from proteins, carbohydrates, lipids, and/or minerals. It is currently difficult to compare the relative advantages and disadvantages of different kinds of nanoparticle-based delivery systems because researchers use different analytical instruments and protocols to characterize them. In this paper, we briefly review the various analytical methods available for characterizing the properties of edible nanoparticles, such as composition, morphology, size, charge, physical state, and stability. This information is then used to propose a number of standardized protocols for characterizing nanoparticle properties, for evaluating their stability to environmental stresses, and for predicting their biological fate. Implementation of these protocols would facilitate comparison of the performance of nanoparticles under standardized conditions, which would facilitate the rational selection of nanoparticle-based delivery systems for different applications in the food, health care, and pharmaceutical industries.

  3. Standard Test Methods for Solar Energy Transmittance and Reflectance (Terrestrial) of Sheet Materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1971-01-01

    1.1 These test methods cover the measurement of solar energy transmittance and reflectance (terrestrial) of materials in sheet form. Method A, using a spectrophotometer, is applicable for both transmittance and reflectance and is the referee method. Method B is applicable only for measurement of transmittance using a pyranometer in an enclosure and the sun as the energy source. Specimens for Method A are limited in size by the geometry of the spectrophotometer while Method B requires a specimen 0.61 m2 (2 ft2). For the materials studied by the drafting task group, both test methods give essentially equivalent results. 1.2 This standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  4. 75 FR 60616 - Commission Guidance Regarding Auditing, Attestation, and Related Professional Practice Standards...

    Science.gov (United States)

    2010-10-01

    ... Regarding Auditing, Attestation, and Related Professional Practice Standards Related To Brokers and Dealers... Oversight Board in the Dodd-Frank Wall Street Reform and Consumer Protection Act to establish auditing... 60617

  5. Standard test methods for elevated temperature tension tests of metallic materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 These test methods cover procedure and equipment for the determination of tensile strength, yield strength, elongation, and reduction of area of metallic materials at elevated temperatures. 1.2 Determination of modulus of elasticity and proportional limit are not included. 1.3 Tension tests under conditions of rapid heating or rapid strain rates are not included. 1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  6. TL glow ratios at different temperature intervals of integration in thermoluminescence method. Comparison of Japanese standard (MHLW notified) method with CEN standard methods

    International Nuclear Information System (INIS)

    Todoriki, Setsuko; Saito, Kimie; Tsujimoto, Yuka

    2008-01-01

    The effect of the integration temperature intervals of TL intensities on the TL glow ratio was examined in comparison of the notified method of the Ministry of Health, Labour and Welfare (MHLW method) with EN1788. Two kinds of un-irradiated geological standard rock and three kinds of spices (black pepper, turmeric, and oregano) irradiated at 0.3 kGy or 1.0 kGy were subjected to TL analysis. Although the TL glow ratio exceeded 0.1 in the andesite according to the calculation of the MHLW notified method (integration interval; 70-490degC), the maximum of the first glow were observed at 300degC or more, attributed the influence of the natural radioactivity and distinguished from food irradiation. When the integration interval was set to 166-227degC according to EN1788, the TL glow ratios became remarkably smaller than 0.1, and the evaluation of the un-irradiated sample became more clear. For spices, the TL glow ratios by the MHLW notified method fell below 0.1 in un-irradiated samples and exceeded 0.1 in irradiated ones. Moreover, Glow1 maximum temperatures of the irradiated samples were observed at the range of 168-196degC, and those of un-irradiated samples were 258degC or more. Therefore, all samples were correctly judged by the criteria of the MHLW method. However, based on the temperature range of integration defined by EN1788, the TL glow ratio of un-irradiated samples remarkably became small compared with that of the MHLW method, and the discrimination of the irradiated sample from non-irradiation sample became clearer. (author)

  7. Standard test method for liquid impingement erosion using rotating apparatus

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This test method covers tests in which solid specimens are eroded or otherwise damaged by repeated discrete impacts of liquid drops or jets. Among the collateral forms of damage considered are degradation of optical properties of window materials, and penetration, separation, or destruction of coatings. The objective of the tests may be to determine the resistance to erosion or other damage of the materials or coatings under test, or to investigate the damage mechanisms and the effect of test variables. Because of the specialized nature of these tests and the desire in many cases to simulate to some degree the expected service environment, the specification of a standard apparatus is not deemed practicable. This test method gives guidance in setting up a test, and specifies test and analysis procedures and reporting requirements that can be followed even with quite widely differing materials, test facilities, and test conditions. It also provides a standardized scale of erosion resistance numbers applicab...

  8. Fiscal 2000 project for development of international standards for supporting novel industries. Standardization of methods for testing and evaluating pure titanium; 2000 nendo shinki sangyo shiengata kokusai hyojun kaihatsu jigyo. Jun titan no shiken hyoka hoho

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-03-01

    For the purpose of submitting propositions to ISO (International Organization for Standardization)/TC79 (Light metals and their alloys) and ISO/TC135 (Non-destructive testing), studies were made relating to the standardization of methods for chemical ingredient analysis and non-destructive testing of industrial pure titanium. In the development of an ingredient analysis method for pure titanium, performance standards and analytical allowance were determined for an inductively coupled plasma emission spectrochemical analyzer for vanadium, niobium, cobalt, and boron, which were short of completion in the preceding fiscal year. As for spark discharge emission spectrochemical analysis, analysis methods were newly established for oxygen and hydrogen. In the development of optical flaw detection for pure titanium boards, the quality of test pieces were determined by use of a reference test piece, and studies were made about the kinds of artificially produced flaws and a method for sensitivity calibration. In the development of ultrasonic flaw detection for pure titanium boards, studies were made about the effects of board thickness, kinds of flaws, and of board size. Using the findings, a draft standard was prepared in Japanese for a JIS (Japanese Industrial Standards) proposition and another in English for an ISO proposition. (NEDO)

  9. Standard Guide for Selection of Test Methods for Interlayer Materials for Aerospace Transparent Enclosures

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2002-01-01

    1.1 This guide summarizes the standard test methods available for determining physical and mechanical characteristics of interlayer materials used in multi-ply aerospace transparent enclosures. 1.2 Interlayer materials are used to laminate glass-to-glass, glass-to-plastic, and plastic-to-plastic. Interlayer materials are basically transparent adhesives with high-quality optical properties. They can also serve as an energy absorbing medium, a fail-safe membrane to contain cockpit pressure and to prevent entry of impact debris; a strain insulator to accommodate different thermal expansion rates of members being laminated and as an adherent to prevent spalling of inner surface ply material fragments. The relative importance of an interlayer characteristic will be a function of the prime use it serves in its particular application. 1.3 This guide, as a summary of various methods in Section 2, is intended to facilitate the selection of tests that can be applied to interlayer materials. 1.4 The test methods list...

  10. 46 CFR 164.023-3 - Specifications and standards incorporated by reference.

    Science.gov (United States)

    2010-10-01

    ... are: Federal Standards and Test Method Standards The following test methods in Federal Test Method Standard No. 191A, Textile Test Methods, July 20, 1978: (1) Method 4010, Length-Weight Relation; Thread..., Polyester Core: Cotton-, Rayon-, or Polyester-Covered, September 30, 1986—164.023-5. (7) MIL-T-43624A—Thread...

  11. Norms and international standards related to reduce risk management: A literature review

    Directory of Open Access Journals (Sweden)

    César Fuentes

    2011-09-01

    Full Text Available The current work aims to develop a revision of the literature within the main concepts in the international rules and standards related to risk management in companies. By this way, there will be an analysis of issues such as the COSO - ERM model, an introduction to the ISO 27000 and 31000 standards; and the Project Management according to PMI targeted at risk management

  12. Stability and non-standard finite difference method of the generalized Chua's circuit

    KAUST Repository

    Radwan, Ahmed G.

    2011-08-01

    In this paper, we develop a framework to obtain approximate numerical solutions of the fractional-order Chua\\'s circuit with Memristor using a non-standard finite difference method. Chaotic response is obtained with fractional-order elements as well as integer-order elements. Stability analysis and the condition of oscillation for the integer-order system are discussed. In addition, the stability analyses for different fractional-order cases are investigated showing a great sensitivity to small order changes indicating the poles\\' locations inside the physical s-plane. The GrnwaldLetnikov method is used to approximate the fractional derivatives. Numerical results are presented graphically and reveal that the non-standard finite difference scheme is an effective and convenient method to solve fractional-order chaotic systems, and to validate their stability. © 2011 Elsevier Ltd. All rights reserved.

  13. Standard Test Method for Measuring Heat-Transfer Rate Using a Thermal Capacitance (Slug) Calorimeter

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 This test method describes the measurement of heat transfer rate using a thermal capacitance-type calorimeter which assumes one-dimensional heat conduction into a cylindrical piece of material (slug) with known physical properties. 1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. 1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. Note 1—For information see Test Methods E 285, E 422, E 458, E 459, and E 511.

  14. Standard test method for plutonium by Iron (II)/Chromium (VI) amperometric titration

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2002-01-01

    1.1 This test method covers the determination of plutonium in unirradiated nuclear-grade plutonium dioxide, uranium-plutonium mixed oxides with uranium (U)/plutonium (Pu) ratios up to 21, plutonium metal, and plutonium nitrate solutions. Optimum quantities of plutonium to measure are 7 to 15 mg. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  15. Standard Test Method for Half-Cell Potentials of Uncoated Reinforcing Steel in Concrete

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This test method covers the estimation of the electrical corrosion potential of uncoated reinforcing steel in field and laboratory concrete, for the purpose of determining the corrosion activity of the reinforcing steel. 1.2 This test method is limited by electrical circuitry. Concrete surface in building interiors and desert environments lose sufficient moisture so that the concrete resistivity becomes so high that special testing techniques not covered in this test method may be required (see 5.1.4.1). Concrete surfaces that are coated or treated with sealers may not provide an acceptable electrical circuit. The basic configuration of the electrical circuit is shown in Fig. 1. 1.3 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It ...

  16. DAG expression: high-throughput gene expression analysis of real-time PCR data using standard curves for relative quantification.

    Directory of Open Access Journals (Sweden)

    María Ballester

    Full Text Available BACKGROUND: Real-time quantitative PCR (qPCR is still the gold-standard technique for gene-expression quantification. Recent technological advances of this method allow for the high-throughput gene-expression analysis, without the limitations of sample space and reagent used. However, non-commercial and user-friendly software for the management and analysis of these data is not available. RESULTS: The recently developed commercial microarrays allow for the drawing of standard curves of multiple assays using the same n-fold diluted samples. Data Analysis Gene (DAG Expression software has been developed to perform high-throughput gene-expression data analysis using standard curves for relative quantification and one or multiple reference genes for sample normalization. We discuss the application of DAG Expression in the analysis of data from an experiment performed with Fluidigm technology, in which 48 genes and 115 samples were measured. Furthermore, the quality of our analysis was tested and compared with other available methods. CONCLUSIONS: DAG Expression is a freely available software that permits the automated analysis and visualization of high-throughput qPCR. A detailed manual and a demo-experiment are provided within the DAG Expression software at http://www.dagexpression.com/dage.zip.

  17. Comparison of Standard and Fast Charging Methods for Electric Vehicles

    Directory of Open Access Journals (Sweden)

    Petr Chlebis

    2014-01-01

    Full Text Available This paper describes a comparison of standard and fast charging methods used in the field of electric vehicles and also comparison of their efficiency in terms of electrical energy consumption. The comparison was performed on three-phase buck converter, which was designed for EV’s fast charging station. The results were obtained by both mathematical and simulation methods. The laboratory model of entire physical application, which will be further used for simulation results verification, is being built in these days.

  18. Accurate determination of arsenic in arsenobetaine standard solutions of BCR-626 and NMIJ CRM 7901-a by neutron activation analysis coupled with internal standard method.

    Science.gov (United States)

    Miura, Tsutomu; Chiba, Koichi; Kuroiwa, Takayoshi; Narukawa, Tomohiro; Hioki, Akiharu; Matsue, Hideaki

    2010-09-15

    Neutron activation analysis (NAA) coupled with an internal standard method was applied for the determination of As in the certified reference material (CRM) of arsenobetaine (AB) standard solutions to verify their certified values. Gold was used as an internal standard to compensate for the difference of the neutron exposure in an irradiation capsule and to improve the sample-to-sample repeatability. Application of the internal standard method significantly improved linearity of the calibration curve up to 1 microg of As, too. The analytical reliability of the proposed method was evaluated by k(0)-standardization NAA. The analytical results of As in AB standard solutions of BCR-626 and NMIJ CRM 7901-a were (499+/-55)mgkg(-1) (k=2) and (10.16+/-0.15)mgkg(-1) (k=2), respectively. These values were found to be 15-20% higher than the certified values. The between-bottle variation of BCR-626 was much larger than the expanded uncertainty of the certified value, although that of NMIJ CRM 7901-a was almost negligible. Copyright (c) 2010 Elsevier B.V. All rights reserved.

  19. ANSI/ASHRAE/IES Standard 90.1-2010 Performance Rating Method Reference Manual

    Energy Technology Data Exchange (ETDEWEB)

    Goel, Supriya [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Rosenberg, Michael I. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-05-01

    This document is intended to be a reference manual for the Appendix G Performance Rating Method (PRM) of ANSI/ASHRAE/IES Standard 90.1- 2010 (Standard 90.1-2010).The PRM is used for rating the energy efficiency of commercial and high-rise residential buildings with designs that exceed the requirements of Standard 90.1. The procedures and processes described in this manual are designed to provide consistency and accuracy by filling in gaps and providing additional details needed by users of the PRM. It should be noted that this document is created independently from ASHRAE and SSPC 90.1 and is not sanctioned nor approved by either of those entities . Potential users of this manual include energy modelers, software developers and implementers of “beyond code” energy programs. Energy modelers using ASHRAE Standard 90.1-2010 for beyond code programs can use this document as a reference manual for interpreting requirements of the Performance Rating method. Software developers, developing tools for automated creation of the baseline model can use this reference manual as a guideline for developing the rules for the baseline model.

  20. California teachers' perceptions of standards-based reform in middle school science: A mixed-methods study

    Science.gov (United States)

    Leggett, Allison Gail Wilson

    The No Child Left Behind (NCLB) Act of 2001 presented one of the most significant and comprehensive literacy reforms in many years (McDonnell, 2005; U.S. Department of Education, 2006). The era of school accountability and standards based reform has brought many challenges and changes to public schools. Increasingly, public officials and educational administrators are asked to use standards based assessments to make high-stakes decisions, such as whether a student will move on to the next grade level or receive a diploma (American Psychological Association, 2005). It is important to understand any shifts in teachers' perceptions and to identify the changes teachers are making as they implement standards-based reform. This mixed-methods study was designed to assess teachers' perceptions of changes related to standards-based reform as supported by Fullan's (2001) change theory and transformational leadership theory. Survey questions sought to identify teacher perceptions of changes in curriculum, instruction and daily practice as schools documented and incorporated standards-based reform and began focusing on preparing students for the California Standards Test in Science (CSTS). Using descriptive statistical analysis and in-depth interviews, results show favorable insight towards standards-based reform. The survey was distributed to 30 middle school science teachers from 10 low-performing schools in Los Angeles, California. Results were analyzed using Spearman rank-ordered correlations. Interviews were conducted on middle school teachers represented by each grade level. Teachers who receive more support from administrators have more positive attitudes toward all aspects of SBR and the CSTS as measured in this study. No school should overlook the potential of a supportive administration in its effort to improve school programs.

  1. Comparative evaluation of different methods of setting hygienic standards

    International Nuclear Information System (INIS)

    Ramzaev, P.V.; Rodionova, L.F.; Mashneva, N.I.

    1978-01-01

    Long-term experiments were carried out on white mice and rats to study the relative importance of various procedures used in setting hygienic standards for exposure to adverse factors. A variety of radionuclides and chemical substances were tested and the sensitivities to them of various indices of the bodily state were determined. For each index, statistically significant minimal effective concentrations of substances were established

  2. The k0-NAA Standardization Method Using an Am-Be Neutron Source

    International Nuclear Information System (INIS)

    Soliman, N.F.; Mohamed, G.Y.; Hassan, M.F.; Ali, M.A.

    2012-01-01

    Instrumental neutron activation analysis is a well established technique for the analysis of trace elements in different samples. Precise elemental concentrations of Al, Mn, Mg and Na in two unknown geological samples were determined by using the k 0 -standardization method. For such measurements two sets of standard monitors of Gold (Au), Indium (In), Tungsten (W) and Titanium (Ta) were used. One set is bare and the other is cadmium covered. These monitors were used for measuring the irradiation position factors f and α and using the cadmium ratios of the 115 In(n,γ) 116 In and 182 Ta(n,γ) 183 Ta interactions. Neutrons were obtained from CNIF 2 facility that uses an Am-Be radio-isotopic neutron source with a modification to have thermal and epi-thermal neutrons. Measurements were carried out using a gamma-ray spectrometer consisting of a hyper pure germanium detector and necessary associated electronics. The k 0 -standardization method can be used for quality control tests.

  3. The standard centrifuge method accurately measures vulnerability curves of long-vesselled olive stems.

    Science.gov (United States)

    Hacke, Uwe G; Venturas, Martin D; MacKinnon, Evan D; Jacobsen, Anna L; Sperry, John S; Pratt, R Brandon

    2015-01-01

    The standard centrifuge method has been frequently used to measure vulnerability to xylem cavitation. This method has recently been questioned. It was hypothesized that open vessels lead to exponential vulnerability curves, which were thought to be indicative of measurement artifact. We tested this hypothesis in stems of olive (Olea europea) because its long vessels were recently claimed to produce a centrifuge artifact. We evaluated three predictions that followed from the open vessel artifact hypothesis: shorter stems, with more open vessels, would be more vulnerable than longer stems; standard centrifuge-based curves would be more vulnerable than dehydration-based curves; and open vessels would cause an exponential shape of centrifuge-based curves. Experimental evidence did not support these predictions. Centrifuge curves did not vary when the proportion of open vessels was altered. Centrifuge and dehydration curves were similar. At highly negative xylem pressure, centrifuge-based curves slightly overestimated vulnerability compared to the dehydration curve. This divergence was eliminated by centrifuging each stem only once. The standard centrifuge method produced accurate curves of samples containing open vessels, supporting the validity of this technique and confirming its utility in understanding plant hydraulics. Seven recommendations for avoiding artefacts and standardizing vulnerability curve methodology are provided. © 2014 The Authors. New Phytologist © 2014 New Phytologist Trust.

  4. Review of international standards related to the design for control rooms on nuclear power plants

    International Nuclear Information System (INIS)

    Kitamura, Masashi; Yoshikawa, Hidekazu; Fujita, Yushi

    2005-01-01

    The improvement of Human-Machine Interface (HMI) design for control rooms on nuclear power plants (NPP) has been accomplished world wide, especially after the TMI-2 accident. The design process and guidelines are standardized in IEC60964 and supplemental standards as international standard. However, technological update is required due to the increased use of computerized control and monitoring equipment and systems in control rooms on NPP in recent years. Standards are becoming more important for computerized control rooms because there is more freedom to design than conventional hardware based system. For computerized control rooms, standards for hardware and software of HMI systems should be also considered. Standards and guidelines for computerized control rooms on NPP have been developed recently in each body such as IEC, ISO, and IEEE etc. Therefore, reviewing these standards and guidelines related to control rooms design of NPP can be useful not only for revision of the international standards such as IEC60964, but also for users of the standards and guidelines. In this paper, we reviewed the international standards related to the design for control rooms, in the two aspects of HMI design and hardware and software design, considering the undergoing revision work and their application. (author)

  5. The Bland-Altman analysis: Does it have a role in assessing radiation dosimeter performance relative to an established standard?

    International Nuclear Information System (INIS)

    Hill, R.F.; Tofts, P.S.; Baldock, C.

    2010-01-01

    Bland-Altman analysis is used to compare two different methods of measurement and to determine whether a new method of measurement may replace an existing accepted 'gold standard' method. In this work, Bland-Altman analysis has been applied to radiation dosimetry to compare the PTW Markus and Roos parallel plate ionisation chambers and a PTW PinPoint chamber against a Farmer type ionisation chamber which is accepted as the gold standard for radiation dosimetry in the clinic. Depth doses for low energy x-rays beams with energies of 50, 75 and 100 kVp were measured using each of the ionisation chambers. Depth doses were also calculated by interpolation of the data in the British Journal of Radiology (BJR) Report 25. From the Bland-Altman analysis, the mean dose difference between the two parallel plate chambers and the Farmer chambers was 1% over the range of depths measured. The PinPoint chamber gave significant dose differences compared to the Farmer chamber. There were also differences of up to 12% between the BJR Report 25 depth doses and the measured data. For the Bland-Altman plots, the lines representing the limits of agreement were selected to be a particular percentage agreement e.g. 1 or 2%, instead of being based on the standard deviation (σ) of the differences. The Bland-Altman statistical analysis is a powerful tool for making comparisons of ionisation chambers with an ionisation chamber that has been accepted as a 'gold standard'. Therefore we conclude that Bland-Altman analysis does have a role in assessing radiation dosimeter performance relative to an established standard.

  6. Patients’ handling of a standardized medication plan: a pilot study and method development

    Directory of Open Access Journals (Sweden)

    Botermann L

    2016-04-01

    Full Text Available Lea Botermann,1,2 Katrin Krueger,1 Christiane Eickhoff,1 Charlotte Kloft,2 Martin Schulz1–31Department of Medicine, ABDA – Federal Union of German Associations of Pharmacists, Berlin, 2Department of Clinical Pharmacy and Biochemistry, Institute of Pharmacy, Freie Universitaet Berlin, Berlin, 3Department of Pharmacology, Goethe-University Frankfurt, Frankfurt am Main, GermanyPurpose: The Action Plan for Medication Safety by the German Federal Ministry of Health introduced a standardized medication plan (MP, a printable document for the patient. The practical handling needs to be tested before the nationwide implementation in Germany. Therefore, the aims of our study were 1 to develop an instrument to evaluate the usage of the standardized MP, 2 to assess if patients can locate, and 3 understand important information. Moreover, we explored patients’ opinion and suggestions regarding the standardized MP template.Patients and methods: We conducted a cross-sectional study to evaluate the practical handling of the standardized MP. We interviewed 40 adult patients in seven community pharmacies in Germany, who took at least five medicines regularly and gave their written informed consent. The interview consisted of questions regarding finding and understanding information provided on a mock-up MP, patients’ opinion and the execution of the information on the MP by filling pill boxes. We eventually developed a new evaluation method to quantify the practical handling of the MP by rating the pill boxes filled by the patients.Results: Overall, the participants rated the MP positively. Thirty-nine (98% participants found important information on a mock-up standardized MP. Patients were questioned to identify if they understood information on medical intake as it relates to meals. In particular, they were questioned about medicine intake “1 hour before a meal”, which 98% (n=39 interpreted correctly, and “during a meal”, which 100% (n=40

  7. Reducing the risk of failure: Software Quality assurance standards and methods

    International Nuclear Information System (INIS)

    Elphick, J.; Cope, H.

    1992-01-01

    An effective Software Quality Assurance (SQA) program provides an overall approach to software engineering and the establishment of proven methods for the production of reliable software. And, in the authors experience, the overall costs for the software life are diminished with the application of quality methods. In their experience, the issues for implementing quality standards and practices are many. This paper addresses those issues as well as the lessons learned from developing and implementing a number of software quality assurance programs. Their experience includes the development and implementation of their own NRC accepted SQA program and an SQA program for an engineering software developer, as well as developing SQA procedures, standards, and methods for utilities, medical and commercial clients. Some of the issues addressed in this paper are: setting goals and defining quality; applying the software life cycle; addressing organizational issues; providing flexibility and increasing productivity; producing effective documentation; maintaining quality records; Imposing software configuration management; conducting reviews, audits, and controls; verification and validation; and controlling software procurement

  8. More recent robust methods for the estimation of mean and standard deviation of data

    International Nuclear Information System (INIS)

    Kanisch, G.

    2003-01-01

    Outliers in a data set result in biased values of mean and standard deviation. One way to improve the estimation of a mean is to apply tests to identify outliers and to exclude them from the calculations. Tests according to Grubbs or to Dixon, which are frequently used in practice, especially within laboratory intercomparisons, are not very efficient in identifying outliers. Since more than ten years now so-called robust methods are used more and more, which determine mean and standard deviation by iteration and down-weighting values far from the mean, thereby diminishing the impact of outliers. In 1989 the Analytical Methods Committee of the British Royal Chemical Society published such a robust method. Since 1993 the US Environmental Protection Agency published a more efficient and quite versatile method. Mean and standard deviation are calculated by iteration and application of a special weight function for down-weighting outlier candidates. In 2000, W. Cofino et al. published a very efficient robust method which works quite different from the others. It applies methods taken from the basics of quantum mechanics, such as ''wave functions'' associated with each laboratory mean value and matrix algebra (solving eigenvalue problems). In contrast to the other ones, this method includes the individual measurement uncertainties. (orig.)

  9. Review of Sodium and Plutonium related Technical Standards in Trans-Uranium Fuel Fabrication Facilities

    Energy Technology Data Exchange (ETDEWEB)

    Jang, Misuk; Jeon, Jong Seon; Kang, Hyun Sik; Kim, Seoung Rae [NESS, Daejeon (Korea, Republic of)

    2016-10-15

    In this paper, we would introduce and review technical standards related to sodium fire and plutonium criticality safety. This paper may be helpful to identify considerations in the development of equipment, standards, and etc., to meet the safety requirements in the design, construction and operating of TFFF, KAPF and SFR. The feasibility and conceptual designs are being examined on related facilities, for example, TRU Fuel Fabrication Facilities (TFFF), Korea Advanced Pyro-process Facility (KAPF), and Sodium Cooled Fast Reactor (SFR), in Korea. However, the safety concerns of these facilities have been controversial in part because of the Sodium fire accident and Plutonium related radiation safety caused by transport and handling accident. Thus, many researches have been performed to ensure safety and various documents including safety requirements have been developed. In separating and reducing the long-lived radioactive transuranic(TRU) in the spent nuclear fuel, reusing as the potential energy of uranium fuel resources and reducing the high level wastes, TFFF would be receiving the attention of many people. Thus, people would wonder whether compliance with technical standards that ensures safety. For new facility design, one of the important tasks is to review of technical standards, especially for sodium and Plutonium because of water related highly reactive characteristics and criticality hazard respectively. We have introduced and reviewed two important technical standards for TFFF, which are sodium fire and plutonium criticality safety, in this paper. This paper would provide a brief guidance, about how to start and what is important, to people who are responsible for the initial design to operation of TFFF.

  10. Review of Sodium and Plutonium related Technical Standards in Trans-Uranium Fuel Fabrication Facilities

    International Nuclear Information System (INIS)

    Jang, Misuk; Jeon, Jong Seon; Kang, Hyun Sik; Kim, Seoung Rae

    2016-01-01

    In this paper, we would introduce and review technical standards related to sodium fire and plutonium criticality safety. This paper may be helpful to identify considerations in the development of equipment, standards, and etc., to meet the safety requirements in the design, construction and operating of TFFF, KAPF and SFR. The feasibility and conceptual designs are being examined on related facilities, for example, TRU Fuel Fabrication Facilities (TFFF), Korea Advanced Pyro-process Facility (KAPF), and Sodium Cooled Fast Reactor (SFR), in Korea. However, the safety concerns of these facilities have been controversial in part because of the Sodium fire accident and Plutonium related radiation safety caused by transport and handling accident. Thus, many researches have been performed to ensure safety and various documents including safety requirements have been developed. In separating and reducing the long-lived radioactive transuranic(TRU) in the spent nuclear fuel, reusing as the potential energy of uranium fuel resources and reducing the high level wastes, TFFF would be receiving the attention of many people. Thus, people would wonder whether compliance with technical standards that ensures safety. For new facility design, one of the important tasks is to review of technical standards, especially for sodium and Plutonium because of water related highly reactive characteristics and criticality hazard respectively. We have introduced and reviewed two important technical standards for TFFF, which are sodium fire and plutonium criticality safety, in this paper. This paper would provide a brief guidance, about how to start and what is important, to people who are responsible for the initial design to operation of TFFF

  11. Method for Estimating Evaporative Potential (IM/CLO) from ASTM Standard Single Wind Velocity Measures

    Science.gov (United States)

    2016-08-10

    IM/CLO) FROM ASTM STANDARD SINGLE WIND VELOCITY MEASURES DISCLAIMER The opinions or assertions contained herein are the private views of the...USARIEM TECHNICAL REPORT T16-14 METHOD FOR ESTIMATING EVAPORATIVE POTENTIAL (IM/CLO) FROM ASTM STANDARD SINGLE WIND VELOCITY... ASTM STANDARD SINGLE WIND VELOCITY MEASURES Adam W. Potter Biophysics and Biomedical Modeling Division U.S. Army Research Institute of Environmental

  12. An Investigation of Undefined Cut Scores with the Hofstee Standard-Setting Method

    Science.gov (United States)

    Wyse, Adam E.; Babcock, Ben

    2017-01-01

    This article provides an overview of the Hofstee standard-setting method and illustrates several situations where the Hofstee method will produce undefined cut scores. The situations where the cut scores will be undefined involve cases where the line segment derived from the Hofstee ratings does not intersect the score distribution curve based on…

  13. Modification of Displacement Coefficient Method in Estimation of Target Displacement for Regular Concrete Bridges Based on ASCE 41-06 Standard

    Directory of Open Access Journals (Sweden)

    Seyed Bahram Beheshti-Aval

    2015-06-01

    Full Text Available Displacement Coefficient Method (DCM stipulated in the ASCE 41-06 standard is becoming the preferred method for seismic rehabilitation of buildings in many high-seismic-hazard countries. Applications of the method for non-building constructions such as bridges are beyond the scope of this standard. Thus its application to this kind of structure should be approached with care. Target displacement has reasonable accuracy for buildings with strong columns and weak beams, where there is the development of plastic hinges. Due to high stiffness and strength of the deck relative to the piers in most bridges, this mechanism does not occur, and it is necessary to evaluate the accuracy of DCM for such structures. In this research, an attempt is made to evaluate the credibility of DCM in the ASCE/SEI 41-06 standard for estimating target drifts in concrete regular bridges under strong ground motions. To apply the extension of the method to bridge structures, the definition of new correction factor CB, which should be multiplied to previous coefficients, is required. This novel coefficient can improve the accuracy of the mentioned method in accessing seismic displacement demands. The coefficient is presented for soil types A to D based on NEHRP soil classification. The validity of the modified DCM is examined for several bridges with use of nonlinear dynamic analysis. Good correlation is found between both procedures.

  14. Validation of uncertainty of weighing in the preparation of radionuclide standards by Monte Carlo Method

    International Nuclear Information System (INIS)

    Cacais, F.L.; Delgado, J.U.; Loayza, V.M.

    2016-01-01

    In preparing solutions for the production of radionuclide metrology standards is necessary measuring the quantity Activity by mass. The gravimetric method by elimination is applied to perform weighing with smaller uncertainties. At this work is carried out the validation, by the Monte Carlo method, of the uncertainty calculation approach implemented by Lourenco and Bobin according to ISO GUM for the method by elimination. The results obtained by both uncertainty calculation methods were consistent indicating that were fulfilled the conditions for the application of ISO GUM in the preparation of radioactive standards. (author)

  15. Standard Test Method for Hydrophobic Surface Films by the Atomizer Test

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1965-01-01

    1.1 This test method covers the detection of the presence of hydrophobic (nonwetting) films on surfaces and the presence of hydrophobic organic materials in processing ambients. When properly conducted, the test will enable detection of fractional molecular layers of hydrophobic organic contaminants. On very rough or porous surfaces the sensitivity of the test may be significantly decreased. 1.2 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are for information only. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  16. Simplified propagation of standard uncertainties

    International Nuclear Information System (INIS)

    Shull, A.H.

    1997-01-01

    An essential part of any measurement control program is adequate knowledge of the uncertainties of the measurement system standards. Only with an estimate of the standards'' uncertainties can one determine if the standard is adequate for its intended use or can one calculate the total uncertainty of the measurement process. Purchased standards usually have estimates of uncertainty on their certificates. However, when standards are prepared and characterized by a laboratory, variance propagation is required to estimate the uncertainty of the standard. Traditional variance propagation typically involves tedious use of partial derivatives, unfriendly software and the availability of statistical expertise. As a result, the uncertainty of prepared standards is often not determined or determined incorrectly. For situations meeting stated assumptions, easier shortcut methods of estimation are now available which eliminate the need for partial derivatives and require only a spreadsheet or calculator. A system of simplifying the calculations by dividing into subgroups of absolute and relative uncertainties is utilized. These methods also incorporate the International Standards Organization (ISO) concepts for combining systematic and random uncertainties as published in their Guide to the Expression of Measurement Uncertainty. Details of the simplified methods and examples of their use are included in the paper

  17. Standard test method for wear testing with a pin-on-disk apparatus

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2005-01-01

    1.1 This test method covers a laboratory procedure for determining the wear of materials during sliding using a pin-on-disk apparatus. Materials are tested in pairs under nominally non-abrasive conditions. The principal areas of experimental attention in using this type of apparatus to measure wear are described. The coefficient of friction may also be determined. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  18. Systematic review: work-related stress and the HSE management standards.

    Science.gov (United States)

    Brookes, K; Limbert, C; Deacy, C; O'Reilly, A; Scott, S; Thirlaway, K

    2013-10-01

    The Health and Safety Executive (HSE) has defined six management standards representing aspects of work that, if poorly managed, are associated with lower levels of employee health and productivity, and increased sickness absence. The HSE indicator tool aims to measure organizations' performance in managing the primary stressors identified by the HSE management standards. The aims of the study are to explore how the HSE indicator tool has been implemented within organizations and to identify contexts in which the tool has been used, its psychometric properties and relationships with alternative measures of well-being and stress. Studies that matched specific criteria were included in the review. Abstracts were considered by two researchers to ensure a reliable process. Full texts were obtained when abstracts met the inclusion criteria. Thirteen papers were included in the review. Using factor analysis and measures of reliability, the studies suggest that the HSE indicator tool is a psychometrically sound measure. The tool has been used to measure work-related stress across different occupational groups, with a clear relationship between the HSE tool and alternative measures of well-being. Limitations of the tool and recommendations for future research are discussed. The HSE indicator tool is a psychometrically sound measure of organizational performance against the HSE management standards. As such it can provide a broad overview of sources of work-related stress within organizations. More research is required to explore the use of the tool in the design of interventions to reduce stress, and its use in different contexts and with different cultural and gender groups.

  19. Project in fiscal 2000 of developing international standards for supporting new industries. Standardization of evaluation method for gene inspection system; 2000 nendo shinki sangyo shiengata kokusai hyojunka kaihatsu jigyo seika hokokusho. Idenshi kensa system no hyoka hoho no hyojunka

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-03-01

    Discussions and deliberations were given by the comprehensive survey committee on standardization of a total gene inspection system from specimen adjustment necessary for the gene inspection system to data processing. This paper summarizes the achievements in fiscal 2000. In standardization related to the specimen procedure and the inspection technique, the specimen storing method and the report statement contents were established. In addition, verification was made on the heat-resistant enzyme reagent and such measuring devices as the electric migration device and the photographing device. Discussions were given on standard substances used in the gene inspection. Regarding the K562 cell strain, cross-checking was performed in three institutions, wherein discussions were given on interchangeability of the inspection results, and the usefulness of the K562 cell as a standard substance. As a result, all the three institutions have come to an agreement on the Southern method, the FISH method and the RT-PCR method, but not on the real-time PT-PCR method, leaving the subject as the future assignment. In the survey for Europe and America, visits were made to AFNOR, CEN, DIN, FDA and CAP for the attempt of collecting information and establishing international exchange. (NEDO)

  20. Fiscal 2000 project for development of international standards for supporting novel industries. Standardization of methods for testing and evaluating plastic optical fiber; 2000 nendo shinki sangyo shiengata kokusai hyojun kaihatsu jigyo seika hokokusho. Plastic hikari fiber no shiken hoho no hyojunka

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-03-01

    Studies were made about methods for testing and evaluating plastic optical fiber (POF) for the purpose of submitting a proposition to IEC (International Electrotechnical Commission) for the methods to be internationally standardized. In this fiscal year, tests and analyses were conducted relative to the effects of the light source emission area size, wavelength, and axial displacement. Next, underfilled launch was studied from a practical viewpoint, and a method using a mode filter was proposed. Finally, round robin tests were conducted for each of the companies using overfilled launch and underfilled launch, and the reproducibility of measured values was grasped. In this fiscal year, a new study added, which involved a method for measuring structural parameters. Though POF was below standard as an object of IEC's gray scale method, yet it was found, thanks to the recently developed CCD (charge coupled device) cameras, that the method might also be applicable to POF. A groundwork plan was drafted on band test methods including the overfilled launch method toward international standardization. (NEDO)

  1. Gas measuring apparatus with standardization means, and method therefor

    International Nuclear Information System (INIS)

    Typpo, P.M.

    1980-01-01

    An apparatus and a method for standardizing a gas measuring device has a source capable of emitting a beam of radiation aligned to impinge a detector. A housing means encloses the beam. The housing means has a plurality of apertures permitting the gas to enter the housing means, to intercept the beam, and to exit from the housing means. The device further comprises means for closing the apertures and a means for purging said gas from the housing means

  2. Condition Assessment Survey (CAS) Program. Deficiency standards and inspections methods manual: Volume 7, 0.07 Conveying

    Energy Technology Data Exchange (ETDEWEB)

    1993-05-01

    System information is given for asset determinant factor/CAS repair codes/CAS cost factors; guide sheet tool & material listing; testing methods; inspection frequency; standard system design life tables; and system work breakdown structure. Deficiency standards and inspection methods are presented for elevators and special conveyors.

  3. Private Animal Welfare Standards-Opportunities and Risks.

    Science.gov (United States)

    Lundmark, Frida; Berg, Charlotte; Röcklinsberg, Helena

    2018-01-02

    The current shift moves the governance of animal welfare away from the government towards the private market and the consumers. We have studied the intentions, content, and on-farm inspection results from different sets of animal welfare legislation and private standards with an aim to highlight the most important opportunities and risks identified in relation to the trend of increasingly relying on private standards for safeguarding or improving farm animal welfare. Our results show that different focuses, intentions, animal welfare requirements, inspection methods (i.e., methods for measuring and evaluating the compliance with a regulation), and inspection results, together with the use of vague wordings and a drive towards more flexible regulations does certainly not facilitate the interpretation and implementation of animal welfare regulations, especially not in relation to each other. Since farmers today often have to comply with several animal welfare regulations, including private standards, it is important to stress that a given regulation should never be seen as a single, stand-alone phenomenon, and the policymakers must hence consider the bigger picture, and apply the standards in relation to other existing regulations. This is especially relevant in relation to the legislation, a level that a private standard can never ignore.

  4. TYPE II-P SUPERNOVAE FROM THE SDSS-II SUPERNOVA SURVEY AND THE STANDARDIZED CANDLE METHOD

    International Nuclear Information System (INIS)

    D'Andrea, Chris B.; Sako, Masao; Dilday, Benjamin; Jha, Saurabh; Frieman, Joshua A.; Kessler, Richard; Holtzman, Jon; Konishi, Kohki; Yasuda, Naoki; Schneider, D. P.; Sollerman, Jesper; Wheeler, J. Craig; Cinabro, David; Nichol, Robert C.; Lampeitl, Hubert; Smith, Mathew; Atlee, David W.; Bassett, Bruce; Castander, Francisco J.; Goobar, Ariel

    2010-01-01

    We apply the Standardized Candle Method (SCM) for Type II Plateau supernovae (SNe II-P), which relates the velocity of the ejecta of a SN to its luminosity during the plateau, to 15 SNe II-P discovered over the three season run of the Sloan Digital Sky Survey-II Supernova Survey. The redshifts of these SNe-0.027 0.01) as all of the current literature on the SCM combined. We find that the SDSS SNe have a very small intrinsic I-band dispersion (0.22 mag), which can be attributed to selection effects. When the SCM is applied to the combined SDSS-plus-literature set of SNe II-P, the dispersion increases to 0.29 mag, larger than the scatter for either set of SNe separately. We show that the standardization cannot be further improved by eliminating SNe with positive plateau decline rates, as proposed in Poznanski et al. We thoroughly examine all potential systematic effects and conclude that for the SCM to be useful for cosmology, the methods currently used to determine the Fe II velocity at day 50 must be improved, and spectral templates able to encompass the intrinsic variations of Type II-P SNe will be needed.

  5. Standard test method for measurement of roll wave optical distortion in heat-treated flat glass

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 This test method is applicable to the determination of the peak-to-valley depth and peak-to-peak distances of the out-of-plane deformation referred to as roll wave which occurs in flat, heat-treated architectural glass substrates processed in a heat processing continuous or oscillating conveyance oven. 1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.3 This test method does not address other flatness issues like edge kink, ream, pocket distortion, bow, or other distortions outside of roll wave as defined in this test method. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  6. Determination of Impurities in Aluminum Alloy by INAA Single Comparator Method (K0-Standardization Method)

    International Nuclear Information System (INIS)

    Sarheel, A.; Khamis, I.; Somel, N.

    2007-01-01

    Multielement determination by the k0 based INAA using k0-IAEA program has been performed at Syrian Atomic Energy Commission using alloys. Concentrations of Cu, Zn, Fe, Ni, Sn and Ti in addition to aluminum element were determined in an aluminum alloy and Ni, Cr, Mo were determined in dental alloys using INAA k0-standardization method. Al-0.1%Au, Ni and Zn certified reference materials were analyzed to assess the suitability and accuracy of the method. Elements were determined in reference materials and samples after short and long irradiations, according to element half-lives.

  7. Standard test method for the radiochemical determination of americium-241 in soil by alpha spectrometry

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2007-01-01

    1.1 This method covers the determination of americium–241 in soil by means of chemical separations and alpha spectrometry. It is designed to analyze up to ten grams of soil or other sample matrices that contain up to 30 mg of combined rare earths. This method allows the determination of americium–241 concentrations from ambient levels to applicable standards. The values stated in SI units are to be regarded as standard. 1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific precaution statements, see Section 10.

  8. A Standardized Method for 4D Ultrasound-Guided Peripheral Nerve Blockade and Catheter Placement

    Directory of Open Access Journals (Sweden)

    N. J. Clendenen

    2014-01-01

    Full Text Available We present a standardized method for using four-dimensional ultrasound (4D US guidance for peripheral nerve blocks. 4D US allows for needle tracking in multiple planes simultaneously and accurate measurement of the local anesthetic volume surrounding the nerve following injection. Additionally, the morphology and proximity of local anesthetic spread around the target nerve is clearly seen with the described technique. This method provides additional spatial information in real time compared to standard two-dimensional ultrasound.

  9. CrowdMapping: A Crowdsourcing-Based Terminology Mapping Method for Medical Data Standardization.

    Science.gov (United States)

    Mao, Huajian; Chi, Chenyang; Huang, Boyu; Meng, Haibin; Yu, Jinghui; Zhao, Dongsheng

    2017-01-01

    Standardized terminology is the prerequisite of data exchange in analysis of clinical processes. However, data from different electronic health record systems are based on idiosyncratic terminology systems, especially when the data is from different hospitals and healthcare organizations. Terminology standardization is necessary for the medical data analysis. We propose a crowdsourcing-based terminology mapping method, CrowdMapping, to standardize the terminology in medical data. CrowdMapping uses a confidential model to determine how terminologies are mapped to a standard system, like ICD-10. The model uses mappings from different health care organizations and evaluates the diversity of the mapping to determine a more sophisticated mapping rule. Further, the CrowdMapping model enables users to rate the mapping result and interact with the model evaluation. CrowdMapping is a work-in-progress system, we present initial results mapping terminologies.

  10. Standard test method for linear thermal expansion of glaze frits and ceramic whiteware materials by the interferometric method

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1995-01-01

    1.1 This test method covers the interferometric determination of linear thermal expansion of premelted glaze frits and fired ceramic whiteware materials at temperatures lower than 1000°C (1830°F). 1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  11. Wavelength selection method with standard deviation: application to pulse oximetry.

    Science.gov (United States)

    Vazquez-Jaccaud, Camille; Paez, Gonzalo; Strojnik, Marija

    2011-07-01

    Near-infrared spectroscopy provides useful biological information after the radiation has penetrated through the tissue, within the therapeutic window. One of the significant shortcomings of the current applications of spectroscopic techniques to a live subject is that the subject may be uncooperative and the sample undergoes significant temporal variations, due to his health status that, from radiometric point of view, introduce measurement noise. We describe a novel wavelength selection method for monitoring, based on a standard deviation map, that allows low-noise sensitivity. It may be used with spectral transillumination, transmission, or reflection signals, including those corrupted by noise and unavoidable temporal effects. We apply it to the selection of two wavelengths for the case of pulse oximetry. Using spectroscopic data, we generate a map of standard deviation that we propose as a figure-of-merit in the presence of the noise introduced by the living subject. Even in the presence of diverse sources of noise, we identify four wavelength domains with standard deviation, minimally sensitive to temporal noise, and two wavelengths domains with low sensitivity to temporal noise.

  12. Standardization of electron-capture and complex beta-gamma radionuclides by the efficiency extrapolation method

    International Nuclear Information System (INIS)

    Grigorescu, L.

    1976-07-01

    The efficiency extrapolation method was improved by establishing ''linearity conditions'' for the discrimination on the gamma channel of the coincidence equipment. These conditions were proved to eliminate the systematic error of the method. A control procedure for the fulfilment of linearity conditions and estimation of residual systematic error was given. For law-energy gamma transitions an ''equivalent scheme principle'' was established, which allow for a correct application of the method. Solutions of Cs-134, Co-57, Ba-133 and Zn-65 were standardized with an ''effective standard deviation'' of 0.3-0.7 per cent. For Zn-65 ''special linearity conditions'' were applied. (author)

  13. Smart density: a more accurate method of measuring rural residential density for health-related research

    Directory of Open Access Journals (Sweden)

    Gibson Lucinda

    2010-02-01

    Full Text Available Abstract Background Studies involving the built environment have typically relied on US Census data to measure residential density. However, census geographic units are often unsuited to health-related research, especially in rural areas where development is clustered and discontinuous. Objective We evaluated the accuracy of both standard census methods and alternative GIS-based methods to measure rural density. Methods We compared residential density (units/acre in 335 Vermont school neighborhoods using conventional census geographic units (tract, block group and block with two GIS buffer measures: a 1-kilometer (km circle around the school and a 1-km circle intersected with a 100-meter (m road-network buffer. The accuracy of each method was validated against the actual residential density for each neighborhood based on the Vermont e911 database, which provides an exact geo-location for all residential structures in the state. Results Standard census measures underestimate residential density in rural areas. In addition, the degree of error is inconsistent so even the relative rank of neighborhood densities varies across census measures. Census measures explain only 61% to 66% of the variation in actual residential density. In contrast, GIS buffer measures explain approximately 90% of the variation. Combining a 1-km circle with a road-network buffer provides the closest approximation of actual residential density. Conclusion Residential density based on census units can mask clusters of development in rural areas and distort associations between residential density and health-related behaviors and outcomes. GIS-defined buffers, including a 1-km circle and a road-network buffer, can be used in conjunction with census data to obtain a more accurate measure of residential density.

  14. Evaluation of diagnostic tests when there is no gold standard. A review of methods

    NARCIS (Netherlands)

    Rutjes, A. W. S.; Reitsma, J. B.; Coomarasamy, A.; Khan, K. S.; Bossuyt, P. M. M.

    2007-01-01

    OBJECTIVE: To generate a classification of methods to evaluate medical tests when there is no gold standard. METHODS: Multiple search strategies were employed to obtain an overview of the different methods described in the literature, including searches of electronic databases, contacting experts

  15. Another Look at the Method of Y-Standardization in Logit and Probit Models

    DEFF Research Database (Denmark)

    Karlson, Kristian Bernt

    2015-01-01

    This paper takes another look at the derivation of the method of Y-standardization used in sociological analysis involving comparisons of coefficients across logit or probit models. It shows that the method can be derived under less restrictive assumptions than hitherto suggested. Rather than...

  16. 41Ca standardization by the CIEMAT/NIST LSC method

    International Nuclear Information System (INIS)

    Rodriguez Barquero, L.; Los Arcos, J.M.

    1996-01-01

    A procedure for the liquid scintillation counting standardization of the electron-capture nuclide 41 Ca has been successfully developed and applied with 41 CaCl 2 and 41 Ca-(HDEHP) n samples synthesized in the laboratory from 41 CaCO 3 supplied by Oak Ridge National Laboratory. Six scintillators were tested: the organic samples were stable in toluene-alcohol, Ultima-Gold TM and HiSafe III TM for 30 d, whereas the inorganic samples were only stable in toluene-alcohol and HiSafe III TM for the same period of time. Despite of the low counting efficiencies (1%-13%) due to the very low-energy of less than 3.6 keV of the X-rays and Auger electrons of 41 Ca, the stable samples were standardized by the CIEMAT/NIST method to a combined uncertainty of 2.4% over a range of figures of merit of 1.75 to 7.25 ( 3 H equivalent efficiency of 40% to 7%). (orig.)

  17. Relating Standardized Visual Perception Measures to Simulator Visual System Performance

    Science.gov (United States)

    Kaiser, Mary K.; Sweet, Barbara T.

    2013-01-01

    Human vision is quantified through the use of standardized clinical vision measurements. These measurements typically include visual acuity (near and far), contrast sensitivity, color vision, stereopsis (a.k.a. stereo acuity), and visual field periphery. Simulator visual system performance is specified in terms such as brightness, contrast, color depth, color gamut, gamma, resolution, and field-of-view. How do these simulator performance characteristics relate to the perceptual experience of the pilot in the simulator? In this paper, visual acuity and contrast sensitivity will be related to simulator visual system resolution, contrast, and dynamic range; similarly, color vision will be related to color depth/color gamut. Finally, we will consider how some characteristics of human vision not typically included in current clinical assessments could be used to better inform simulator requirements (e.g., relating dynamic characteristics of human vision to update rate and other temporal display characteristics).

  18. Pattern and security requirements engineering-based establishment of security standards

    CERN Document Server

    Beckers, Kristian

    2015-01-01

    Security threats are a significant problem for information technology companies today. This book focuses on how to mitigate these threats by using security standards and provides ways to address associated problems faced by engineers caused by ambiguities in the standards. The security standards are analysed, fundamental concepts of the security standards presented, and the relations to the elementary concepts of security requirements engineering (SRE) methods explored. Using this knowledge, engineers can build customised methods that support the establishment of security standards. Standard

  19. ['Gold standard', not 'golden standard'

    NARCIS (Netherlands)

    Claassen, J.A.H.R.

    2005-01-01

    In medical literature, both 'gold standard' and 'golden standard' are employed to describe a reference test used for comparison with a novel method. The term 'gold standard' in its current sense in medical research was coined by Rudd in 1979, in reference to the monetary gold standard. In the same

  20. Quantification of endogenous metabolites by the postcolumn infused-internal standard method combined with matrix normalization factor in liquid chromatography-electrospray ionization tandem mass spectrometry.

    Science.gov (United States)

    Liao, Hsiao-Wei; Chen, Guan-Yuan; Wu, Ming-Shiang; Liao, Wei-Chih; Tsai, I-Lin; Kuo, Ching-Hua

    2015-01-02

    Quantification of endogenous metabolites has enabled the discovery of biomarkers for diagnosis and provided for an understanding of disease etiology. The standard addition and stable isotope labeled-internal standard (SIL-IS) methods are currently the most widely used approaches to quantifying endogenous metabolites, but both have some limitations for clinical measurement. In this study, we developed a new approach for endogenous metabolite quantification by the postcolumn infused-internal standard (PCI-IS) method combined with the matrix normalization factor (MNF) method. MNF was used to correct the difference in MEs between standard solution and biofluids, and PCI-IS additionally tailored the correction of the MEs for individual samples. Androstenedione and testosterone were selected as test articles to verify this new approach to quantifying metabolites in plasma. The repeatability (n=4 runs) and intermediate precision (n=3 days) in terms of the peak area of androstenedione and testosterone at all tested concentrations were all less than 11% relative standard deviation (RSD). The accuracy test revealed that the recoveries were between 95.72% and 113.46%. The concentrations of androstenedione and testosterone in fifty plasma samples obtained from healthy volunteers were quantified by the PCI-IS combined with the MNF method, and the quantification results were compared with the results of the SIL-IS method. The Pearson correlation test showed that the correlation coefficient was 0.98 for both androstenedione and testosterone. We demonstrated that the PCI-IS combined with the MNF method is an effective and accurate method for quantifying endogenous metabolites. Copyright © 2014 Elsevier B.V. All rights reserved.

  1. Instructional Basics: Oppelt Standard Method of Therapeutic and Recreational Ice Skating.

    Science.gov (United States)

    Oppelt, Kurt

    Detailed in the booklet is the standard ice skating method and considered are the benefits of therapeutic ice skating for the handicapped and aged. Values for the mentally retarded and physically handicapped are seen to include physiological (such as increased flexibility and improved posture), psychological (including satifaction and enhanced…

  2. Standard test methods for chemical and spectrochemical analysis of nuclear-Grade silver-indium-cadmium alloys

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1990-01-01

    1.1 These test methods cover procedures for the chemical and spectrochemical analysis of nuclear grade silver-indium-cadmium (Ag-In-Cd) alloys to determine compliance with specifications. 1.2 The analytical procedures appear in the following order: Sections Silver, Indium, and Cadmium by a Titration Method 7-15 Trace Impurities by Carrier-Distillation Spectro- chemical Method 16-22 1.3 The values stated in SI units are to be regarded as the standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific hazard and precautionary statements, see Section 5 and Practices E50. 7.1 This test method is applicable to the determination of silver, indium, and cadmium in alloys of approximately 80 % silver, 15 % indium, and 5 % cadmium used in nuclear reactor control r...

  3. Calculation of the yearly energy performance of heating systems based on the European Building Energy Directive and related CEN Standards

    DEFF Research Database (Denmark)

    Olesen, Bjarne W.; de Carli, Michele

    2011-01-01

    According to the Energy Performance of Buildings Directive (EPBD) all new European buildings (residential, commercial, industrial, etc.) must since 2006 have an energy declaration based on the calculated energy performance of the building, including heating, ventilating, cooling and lighting syst......–20% of the building energy demand. The additional loss depends on the type of heat emitter, type of control, pump and boiler. Keywords: Heating systems; CEN standards; Energy performance; Calculation methods......According to the Energy Performance of Buildings Directive (EPBD) all new European buildings (residential, commercial, industrial, etc.) must since 2006 have an energy declaration based on the calculated energy performance of the building, including heating, ventilating, cooling and lighting...... systems. This energy declaration must refer to the primary energy or CO2 emissions. The European Organization for Standardization (CEN) has prepared a series of standards for energy performance calculations for buildings and systems. This paper presents related standards for heating systems. The relevant...

  4. The development and standardization of testing methods for genetically modified organisms and their derived products.

    Science.gov (United States)

    Zhang, Dabing; Guo, Jinchao

    2011-07-01

    As the worldwide commercialization of genetically modified organisms (GMOs) increases and consumers concern the safety of GMOs, many countries and regions are issuing labeling regulations on GMOs and their products. Analytical methods and their standardization for GM ingredients in foods and feed are essential for the implementation of labeling regulations. To date, the GMO testing methods are mainly based on the inserted DNA sequences and newly produced proteins in GMOs. This paper presents an overview of GMO testing methods as well as their standardization. © 2011 Institute of Botany, Chinese Academy of Sciences.

  5. Adolescents' Motivation for Reading: Group Differences and Relation to Standardized Achievement

    Science.gov (United States)

    Wolters, Christopher A.; Denton, Carolyn A.; York, Mary J.; Francis, David J.

    2014-01-01

    The purpose of this study was to extend the research on adolescents' motivation for reading by examining important group differences and the relation of motivation to standardized achievement. Adolescents (N = 406) ranging from grade 7 to grade 12 completed a self-report survey that assessed 13 different aspects of their reading motivation…

  6. Self-assembling membranes and related methods thereof

    Science.gov (United States)

    Capito, Ramille M; Azevedo, Helena S; Stupp, Samuel L

    2013-08-20

    The present invention relates to self-assembling membranes. In particular, the present invention provides self-assembling membranes configured for securing and/or delivering bioactive agents. In some embodiments, the self-assembling membranes are used in the treatment of diseases, and related methods (e.g., diagnostic methods, research methods, drug screening).

  7. Do U Txt? Event-Related Potentials to Semantic Anomalies in Standard and Texted English

    Science.gov (United States)

    Berger, Natalie I.; Coch, Donna

    2010-01-01

    Texted English is a hybrid, technology-based language derived from standard English modified to facilitate ease of communication via instant and text messaging. We compared semantic processing of texted and standard English sentences by recording event-related potentials in a classic semantic incongruity paradigm designed to elicit an N400 effect.…

  8. Standard Test Method for Electrical Performance of Photovoltaic Cells Using Reference Cells Under Simulated Sunlight

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This test method covers the determination of the electrical performance of a photovoltaic cell under simulated sunlight by means of a calibrated reference cell procedure. 1.2 Electrical performance measurements are reported with respect to a select set of standard reporting conditions (SRC) (see Table 1) or to user-specified conditions. 1.2.1 The SRC or user-specified conditions include the cell temperature, the total irradiance, and the reference spectral irradiance distribution. 1.3 This test method is applicable only to photovoltaic cells with a linear response over the range of interest. 1.4 The cell parameters determined by this test method apply only at the time of test, and imply no past or future performance level. 1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this s...

  9. Standard guide for corrosion-related failure analysis

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2000-01-01

    1.1 This guide covers key issues to be considered when examining metallic failures when corrosion is suspected as either a major or minor causative factor. 1.2 Corrosion-related failures could include one or more of the following: change in surface appearance (for example, tarnish, rust, color change), pin hole leak, catastrophic structural failure (for example, collapse, explosive rupture, implosive rupture, cracking), weld failure, loss of electrical continuity, and loss of functionality (for example, seizure, galling, spalling, swelling). 1.3 Issues covered include overall failure site conditions, operating conditions at the time of failure, history of equipment and its operation, corrosion product sampling, environmental sampling, metallurgical and electrochemical factors, morphology (mode) or failure, and by considering the preceding, deducing the cause(s) of corrosion failure. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibili...

  10. Standardization of low energy beta and beta-gamma complex emitters by the tracer and the efficiency extrapolation methods

    International Nuclear Information System (INIS)

    Sahagia, M.

    1978-01-01

    The absolute standardization of radioactive solutions of low energy beta emitters and beta-gamma emitters with a high probability of disintegration to the ground state is described; the tracer and the efficiency extrapolation methods were used. Both types of radionuclides were mathematically and physically treated in an unified manner. The theoretical relations between different beta spectra were calculated according to Williams' model and experimentally verified for: 35 S + 60 Co, 35 S + 95 Nb, 147 Pm + 60 Co, 14 C + 95 Nb and two beta branches of 99 Mo. The optimum range of beta efficiency variation was indicated. The basic supposition that all beta efficieny tend to unity in the same time was experimentally verified, using two 192 Ir beta branches. Four computer programs, written in the FORTRAN IV language, were elaborated, for the adequate processing of the experimental data. Good precision coefficients according to international standards were obtained in the absolute standardization of 35 S, 147 Pm, 99 Mo solutions. (author)

  11. Biological durability of wood in relation to end-use - Part 1. Towards a European standard for laboratory testing of the biological durability of wood

    NARCIS (Netherlands)

    Acker, Van J.; Stevens, M.; Carey, J.; Sierra-Alvarez, R.; Militz, H.; Bayon, Le I.; Kleist, G.; Peek, R.D.

    2003-01-01

    The determination of biological durability of wood is an issue requiring sufficient reliability regarding end-use related prediction of performance. Five test institutes joined efforts to check standard test methods and to improve methodology and data interpretation for assessment of natural

  12. A simple web-based tool to compare freshwater fish data collected using AFS standard methods

    Science.gov (United States)

    Bonar, Scott A.; Mercado-Silva, Norman; Rahr, Matt; Torrey, Yuta T.; Cate, Averill

    2016-01-01

    The American Fisheries Society (AFS) recently published Standard Methods for Sampling North American Freshwater Fishes. Enlisting the expertise of 284 scientists from 107 organizations throughout Canada, Mexico, and the United States, this text was developed to facilitate comparisons of fish data across regions or time. Here we describe a user-friendly web tool that automates among-sample comparisons in individual fish condition, population length-frequency distributions, and catch per unit effort (CPUE) data collected using AFS standard methods. Currently, the web tool (1) provides instantaneous summaries of almost 4,000 data sets of condition, length frequency, and CPUE of common freshwater fishes collected using standard gears in 43 states and provinces; (2) is easily appended with new standardized field data to update subsequent queries and summaries; (3) compares fish data from a particular water body with continent, ecoregion, and state data summaries; and (4) provides additional information about AFS standard fish sampling including benefits, ongoing validation studies, and opportunities to comment on specific methods. The web tool—programmed in a PHP-based Drupal framework—was supported by several AFS Sections, agencies, and universities and is freely available from the AFS website and fisheriesstandardsampling.org. With widespread use, the online tool could become an important resource for fisheries biologists.

  13. Reproducibility Between Brain Uptake Ratio Using Anatomic Standardization and Patlak-Plot Methods.

    Science.gov (United States)

    Shibutani, Takayuki; Onoguchi, Masahisa; Noguchi, Atsushi; Yamada, Tomoki; Tsuchihashi, Hiroko; Nakajima, Tadashi; Kinuya, Seigo

    2015-12-01

    The Patlak-plot and conventional methods of determining brain uptake ratio (BUR) have some problems with reproducibility. We formulated a method of determining BUR using anatomic standardization (BUR-AS) in a statistical parametric mapping algorithm to improve reproducibility. The objective of this study was to demonstrate the inter- and intraoperator reproducibility of mean cerebral blood flow as determined using BUR-AS in comparison to the conventional-BUR (BUR-C) and Patlak-plot methods. The images of 30 patients who underwent brain perfusion SPECT were retrospectively used in this study. The images were reconstructed using ordered-subset expectation maximization and processed using an automatic quantitative analysis for cerebral blood flow of ECD tool. The mean SPECT count was calculated from axial basal ganglia slices of the normal side (slices 31-40) drawn using a 3-dimensional stereotactic region-of-interest template after anatomic standardization. The mean cerebral blood flow was calculated from the mean SPECT count. Reproducibility was evaluated using coefficient of variation and Bland-Altman plotting. For both inter- and intraoperator reproducibility, the BUR-AS method had the lowest coefficient of variation and smallest error range about the Bland-Altman plot. Mean CBF obtained using the BUR-AS method had the highest reproducibility. Compared with the Patlak-plot and BUR-C methods, the BUR-AS method provides greater inter- and intraoperator reproducibility of cerebral blood flow measurement. © 2015 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  14. Collectivism versus individualism: performance-related pay and union coverage for non-standard workers in Britain

    OpenAIRE

    Booth, Alison L.; Francesconi, Marco

    2000-01-01

    This paper documents the extent of union coverage and performance-related pay (PRP) - the latter representing one aspect of pay flexibility - across standard and non-standard workers in Britain, using the first seven waves of the British Household Panel Survey, 1991-1997. We find there is no evidence of expansion of either union coverage or PRP towards any type of non-standard employment in the 1990s. Thus union rhetoric about a 'strategy of enlargement' towards non-standard workers remains j...

  15. Methods for measurements of energy and emissions related to motor vehicles: Identification of needs for improvements

    Energy Technology Data Exchange (ETDEWEB)

    Karl-Erik Egebaeck, K.E. [Luleaa Univ. of Technology, Luleaa (Sweden). Dept. of Environmental Technology; Karlsson, Hua L. [MTC AB, Haninge (Sweden); Westerholm, R. [Stockholm Univ. (Sweden). Dept. of Analytical Chemistry

    2002-01-01

    The official methods in use today for emission testing of vehicles and engines were primarily developed for the characterisation of exhaust emissions from motor vehicles fuelled with petrol or diesel oil. The setting of new lower emission standards will make it difficult to obtain sufficient accuracy, using the present systems, for the quantification of exhaust emissions in the future. Development of new emission control technology and improved fuels has made it possible to meet these more stringent standards. Consequently new emission standards will lead to a need for new and improved methodologies and new instrumentation for the characterisation of the emissions from vehicles/engines/fuels. The present report comprises a discussion and comments on questions related to improved methods for emission measurements. The report is based on a study of the literature, site visits to laboratories and research institutes etc in the US and a meeting with representatives of the EU Commission, carried out during the spring of 2001. The conclusions and recommendations in the pre-study report are summarised in sub titles: General, regulated emissions, unregulated emissions, greenhouse gases and fuel consumption. Since the questions and problems discussed have an international connection they should be discussed in an international forum. However, before such discussions can be organised the problems related to measurement of emissions and fuel consumption must be more extensively studied than in this pre-study.

  16. Stability and non-standard finite difference method of the generalized Chua's circuit

    KAUST Repository

    Radwan, Ahmed G.; Moaddy, K.; Momani, Shaher M.

    2011-01-01

    In this paper, we develop a framework to obtain approximate numerical solutions of the fractional-order Chua's circuit with Memristor using a non-standard finite difference method. Chaotic response is obtained with fractional-order elements as well

  17. The Standard Days Method(®): efficacy, satisfaction and demand at regular family planning service delivery settings in Turkey.

    Science.gov (United States)

    Kursun, Zerrin; Cali, Sanda; Sakarya, Sibel

    2014-06-01

    To evaluate the demand, efficacy, and satisfaction concerning the Standard Days Method(®) (SDM; a fertility awareness method) as an option presented among other contraceptive methods at regular service delivery settings. The survey group consisted of 993 women who presented at the primary care units in Umraniye District of Istanbul, Turkey, between 1 October 2006 and 31 March 2008, and started to use a new method. Women were enrolled until reaching a limit of 250 new users for each method, or expiration of the six-month registration period. Participants were followed for up to one year of method use. The characteristics of women who chose the SDM were similar to those of participants who opted for other methods. The most common reasons for selecting it were that it is natural and causes no side effects. Fifty-one percent used the SDM for the full year, compared to 71% who chose an intrauterine device (IUD). Continuation rates were significantly lower for all other methods. During the one-year follow-up period, 12% of SDM-, 7% of pill-, 7% of condom-, 3% of monthly injection-, 1% of quarterly injection-, and 0.5% of IUD users became pregnant. The SDM had relatively high continuation rates and relatively good levels of satisfaction among participants and their husbands. It should be mentioned among the routinely offered contraceptive methods.

  18. Analysing public relations education through international standards: The Portuguese case

    OpenAIRE

    Gonçalves, Gisela Marques Pereira; Spínola, Susana de Carvalho; Padamo, Celma

    2013-01-01

    By using international reports on PR education as a benchmark we analyse the status of PR higher education in Portugal. Despite differences among the study programs, the findings reveal that the standard five courses recommendation by the Commission on Public Relations Education (CPRE) are a part of Portuguese undergraduate curriculum. This includes 12 of the 14 content field guidelines needed to achieve the ideal master's program. Data shows, however, the difficulty of positioning public rel...

  19. Condition Assessment Survey (CAS) Program. Deficiency standards and inspections methods manual: Volume 3, 0.03 Superstructure

    Energy Technology Data Exchange (ETDEWEB)

    1993-05-01

    General information is presented on asset determinant factor/CAS profile codes/CAS cost process; guide sheet tool & material listing; testing methods; inspection frequency; standard system design life tables; system work breakdown structure; and general system/material data. Deficiency standards and inspection methods are presented for beams; pre-engineered building systems; floors; roof structure; stairs; and fireproofing.

  20. Standardization of a method to study angiogenesis in a mouse model

    Directory of Open Access Journals (Sweden)

    DAVID FEDER

    2013-01-01

    Full Text Available In the adult organism, angiogenesis is restricted to a few physiological conditions. On the other hand, uncontrolled angiogenesis have often been associated to angiogenesis-dependent pathologies. A variety of animal models have been described to provide more quantitative analysis of in vivo angiogenesis and to characterize pro- and antiangiogenic molecules. However, it is still necessary to establish a quantitative, reproducible and specific method for studies of angiogenesis factors and inhibitors. This work aimed to standardize a method for the study of angiogenesis and to investigate the effects of thalidomide on angiogenesis. Sponges of 0.5 x 0.5 x 0.5 cm were implanted in the back of mice groups, control and experimental (thalidomide 200 mg/K/day by gavage. After seven days, the sponges were removed. The dosage of hemoglobin in sponge and in circulation was performed and the ratio between the values was tested using nonparametric Mann-Whitney test. Results have shown that sponge-induced angiogenesis quantitated by ratio between hemoglobin content in serum and in sponge is a helpful model for in vivo studies on angiogenesis. Moreover, it was observed that sponge-induced angiogenesis can be suppressed by thalidomide, corroborating to the validity of the standardized method.

  1. Standard test method for color and color difference of whitewares by abriged spectrophotometry

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2001-01-01

    1.1 This test method describes the instrumental measurement of the reflection properties and color of ceramic glazes and other whitewares by the use of a spectrophotometer or spectrocolorimeter with a hemispherical optical measuring system, such as an integrating sphere. 1.2 The test method is suitable for use with most specimens having an exterior flat surface large enough to cover the spectrophotometer sample port. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  2. Standardization of 18F by coincidence and LSC methods

    International Nuclear Information System (INIS)

    Roteta, Miguel; Garcia-Torano, Eduardo; Rodriguez Barquero, Leonor

    2006-01-01

    The nuclide 18 F disintegrates to 18 O by β + emission (96.86%) and electron capture (3.14%) with a half-life of 1.8288 h. It is widely used in nuclear medicine for positron emission tomography (PET). A radioactive solution of this nuclide has been standardized by two techniques: coincidence measurements with a pressurized proportional counter and liquid scintillation counting using the CIEMAT/NIST method. One ampoule containing a solution calibrated in activity was sent for measurement at the International Reference System maintained by the BIPM. Results are in excellent agreement with SIR values

  3. Standard Test Method for Measuring Reaction Rates by Radioactivation of Uranium-238

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 This test method covers procedures for measuring reaction rates by assaying a fission product (F.P.) from the fission reaction 238U(n,f)F.P. 1.2 The reaction is useful for measuring neutrons with energies from approximately 1.5 to 7 MeV and for irradiation times up to 30 to 40 years. 1.3 Equivalent fission neutron fluence rates as defined in Practice E 261 can be determined. 1.4 Detailed procedures for other fast-neutron detectors are referenced in Practice E 261. 1.5 The values stated in SI units are to be regarded as standard. No other unites of measurement are included in this standard. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  4. Standard Test Method for Measuring Reaction Rates by Radioactivation of Neptunium-237

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 This test method covers procedures for measuring reaction rates by assaying a fission product (F.P.) from the fission reaction 237Np(n,f)F.P. 1.2 The reaction is useful for measuring neutrons with energies from approximately 0.7 to 6 MeV and for irradiation times up to 30 to 40 years. 1.3 Equivalent fission neutron fluence rates as defined in Practice E 261 can be determined. 1.4 Detailed procedures for other fast-neutron detectors are referenced in Practice E 261. 1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  5. Standard Test Method for Gravimetric Determination of Nonvolatile Residue from Cleanroom Gloves

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2011-01-01

    1.1 This test method covers the determination of solvent extractable nonvolatile residue (NVR) from gloves used in cleanrooms where spacecraft are assembled, cleaned, or tested. 1.2 The NVR of interest is that which can be extracted from gloves using a specified solvent that has been selected for its extracting qualities, or because it is representative of solvents used in the particular facility. Alternative solvents may be used, but since their use may result in different values being generated, they must be identified in the procedure data sheet. 1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  6. Standard Test Method for Gravimetric Determination of Nonvolatile Residue From Cleanroom Wipers

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2006-01-01

    1.1 This test method covers the determination of solvent extractable nonvolatile residue (NVR) from wipers used in assembly, cleaning, or testing of spacecraft, but not from those used for analytical surface sampling of hardware. 1.2 The values stated in SI units are to be regarded as the standard. No other units of measurement are included in this standard. 1.3 The NVR of interest is that which can be extracted from cleanroom wipers using a specified solvent that has been selected for its extractive qualities. Alternative solvents may be selected, but since their use may result in different values being generated, they must be identified in the procedure data sheet. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  7. Use of sum-peak and coincidence counting methods for activity standardization of {sup 22}Na

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, E.M. de, E-mail: estela@ird.gov.br [Laboratorio Nacional de Metrologia das Radiacoes Ionizantes (LNMRI/IRD/CNEN), Av. Salvador Allende, s/n, Recreio, CEP 22780-160 Rio de Janeiro (Brazil); Iwahara, A.; Poledna, R. [Laboratorio Nacional de Metrologia das Radiacoes Ionizantes (LNMRI/IRD/CNEN), Av. Salvador Allende, s/n, Recreio, CEP 22780-160 Rio de Janeiro (Brazil); Silva, M.A.L. da [Coordenacao Geral de Instalacoes Nucleares/Comissao Nacional de Energia Nuclear, R. Gal. Severiano, 90 - Botafogo, CEP 22290-901 Rio de Janeiro (Brazil); Tauhata, L. [Fundacao Carlos Chagas Filho de Amparo a Pesquisa do Estado do Rio de Janeiro (FAPERJ), Av. Erasmo Braga, 118-6 Degree-Sign andar, CEP 20020-000 Centro, Rio de Janeiro (Brazil); Delgado, J.U. [Laboratorio Nacional de Metrologia das Radiacoes Ionizantes (LNMRI/IRD/CNEN), Av. Salvador Allende, s/n, Recreio, CEP 22780-160 Rio de Janeiro (Brazil); Lopes, R.T. [Laboratorio de Instrumentacao Nuclear (LIN/PEN/COPPE/UFRJ), Caixa Postal 68509, CEP 21945-970 Rio de Janeiro (Brazil)

    2012-09-21

    A solution containing the positron emitter {sup 22}Na has been absolutely standardized using the 4{pi}{beta}-{gamma} coincidence counting method and the sum-peak spectrometry counting method. In the 4{pi}{beta}-{gamma} coincidence method two ways for the activity concentration measurements were used: gating on the 1275 keV photopeak and on the 1786 keV sum-peak where the knowledge of the {beta}{sup +}-branching ratio is required. In the sum-peak method the measurements were carried out using three experimental arrangements: the first composed by a well type 5 in. Multiplication-Sign 5 in. NaI(Tl) scintillation crystal, the second by a 3 in. Multiplication-Sign 3 in. NaI(Tl) scintillation crystal placed on the top of the first, resulting in a 4{pi} counting geometry and the third arrangement is a high purity coaxial germanium detector. The results that are obtained by these two methods are compatible within the standard uncertainty values with a coverage factor of k=2 ({approx}95% of the confidence level). This means that the sum-peak counting with its more simple experimental setup than the complex coincidence 4{pi}{beta}-{gamma} counting system gives consistent results for the activity standardization of {sup 22}Na with smaller uncertainties. Besides, the time period involved to attain the result of the standardization was quite shorter than the coincidence measurements used in this work.

  8. Condition Assessment Survey (CAS) Program. Deficiency standards and inspections methods manual: Volume 12, 0.12 Sitework

    Energy Technology Data Exchange (ETDEWEB)

    1993-05-01

    General information is presented for asset determinant factor/CAS repair codes/CAS cost factors; guide sheet tool & material listing; testing methods; inspection frequency; standard system design life tables; system work breakdown structure; and general system/material data. Deficiency standards and inspection methods are given for utility distribution systems, central heating, central cooling, electrical, utility support structures, paving roadways/walkways, and tunnels.

  9. Condition Assessment Survey (CAS) Program. Deficiency standards and inspections methods manual: Volume 5, 0.05 Roofing

    Energy Technology Data Exchange (ETDEWEB)

    1993-05-01

    General information is presented for asset determinant factor/CAS repair codes/CAS cost factors; guide sheet tool & material listing; testing methods; inspection frequency; standard system design life tables; and system work breakdown structure. Deficiency standards and inspection methods are presented for built-up membrane; single- ply membrane; metal roofing systems; coated foam membrane; shingles; tiles; parapets; roof drainage system; roof specialties; and skylights.

  10. Standard test method for compressive (crushing) strength of fired whiteware materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2006-01-01

    1.1 This test method covers two test procedures (A and B) for the determination of the compressive strength of fired whiteware materials. 1.2 Procedure A is generally applicable to whiteware products of low- to moderately high-strength levels (up to 150 000 psi or 1030 MPa). 1.3 Procedure B is specifically devised for testing of high-strength ceramics (over 100 000 psi or 690 MPa). 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  11. Standard practice for calculation of corrosion rates and related information from electrochemical measurements

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1989-01-01

    1.1 This practice covers the providing of guidance in converting the results of electrochemical measurements to rates of uniform corrosion. Calculation methods for converting corrosion current density values to either mass loss rates or average penetration rates are given for most engineering alloys. In addition, some guidelines for converting polarization resistance values to corrosion rates are provided. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

  12. No-gold-standard evaluation of image-acquisition methods using patient data.

    Science.gov (United States)

    Jha, Abhinav K; Frey, Eric

    2017-02-11

    Several new and improved modalities, scanners, and protocols, together referred to as image-acquisition methods (IAMs), are being developed to provide reliable quantitative imaging. Objective evaluation of these IAMs on the clinically relevant quantitative tasks is highly desirable. Such evaluation is most reliable and clinically decisive when performed with patient data, but that requires the availability of a gold standard, which is often rare. While no-gold-standard (NGS) techniques have been developed to clinically evaluate quantitative imaging methods, these techniques require that each of the patients be scanned using all the IAMs, which is expensive, time consuming, and could lead to increased radiation dose. A more clinically practical scenario is where different set of patients are scanned using different IAMs. We have developed an NGS technique that uses patient data where different patient sets are imaged using different IAMs to compare the different IAMs. The technique posits a linear relationship, characterized by a slope, bias, and noise standard-deviation term, between the true and measured quantitative values. Under the assumption that the true quantitative values have been sampled from a unimodal distribution, a maximum-likelihood procedure was developed that estimates these linear relationship parameters for the different IAMs. Figures of merit can be estimated using these linear relationship parameters to evaluate the IAMs on the basis of accuracy, precision, and overall reliability. The proposed technique has several potential applications such as in protocol optimization, quantifying difference in system performance, and system harmonization using patient data.

  13. Standard Test Method for Hydrophobic Surface Films by the Water-Break Test

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2002-01-01

    1.1 This test method covers the detection of the presence of hydrophobic (nonwetting) films on surfaces and the presence of hydrophobic organic materials in processing ambients. When properly conducted, the test will enable detection of molecular layers of hydrophobic organic contaminants. On very rough or porous surfaces, the sensitivity of the test may be significantly decreased. 1.2 The values stated in SI units are to be regarded as the standard. The inch-pound values given in parentheses are for information only. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  14. Standard test method for determining nodularity and nodule count in ductile iron using image analysis

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2011-01-01

    1.1 This test method is used to determine the percent nodularity and the nodule count per unit area (that is, number of nodules per mm2) using a light microscopical image of graphite in nodular cast iron. Images generated by other devices, such as a scanning electron microscope, are not specifically addressed, but can be utilized if the system is calibrated in both x and y directions. 1.2 Measurement of secondary or temper carbon in other types of cast iron, for example, malleable cast iron or in graphitic tool steels, is not specifically included in this standard because of the different graphite shapes and sizes inherent to such grades 1.3 This standard deals only with the recommended test method and nothing in it should be construed as defining or establishing limits of acceptability or fitness for purpose of the material tested. 1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.5 This standard does not purport to address al...

  15. Standard Test Methods for Properties of Continuous Filament Carbon and Graphite Fiber Tows

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1999-01-01

    1.1 These test methods cover the preparation and tensile testing of resin-impregnated and consolidated test specimens made from continuous filament carbon and graphite yarns, rovings, and tows to determine their tensile properties. 1.2 These test methods also cover the determination of the density and mass per unit length of the yarn, roving, or tow to provide supplementary data for tensile property calculation. 1.3 These test methods include a procedure for sizing removal to provide the preferred desized fiber samples for density measurement. This procedure may also be used to determine the weight percent sizing. 1.4 These test methods include a procedure for determining the weight percent moisture adsorption of carbon or graphite fiber. 1.5 The values stated in SI units are to be regarded as the standard. The values in parentheses are for information only. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of t...

  16. The use of bootstrap methods for analysing health-related quality of life outcomes (particularly the SF-36

    Directory of Open Access Journals (Sweden)

    Campbell Michael J

    2004-12-01

    Full Text Available Abstract Health-Related Quality of Life (HRQoL measures are becoming increasingly used in clinical trials as primary outcome measures. Investigators are now asking statisticians for advice on how to analyse studies that have used HRQoL outcomes. HRQoL outcomes, like the SF-36, are usually measured on an ordinal scale. However, most investigators assume that there exists an underlying continuous latent variable that measures HRQoL, and that the actual measured outcomes (the ordered categories, reflect contiguous intervals along this continuum. The ordinal scaling of HRQoL measures means they tend to generate data that have discrete, bounded and skewed distributions. Thus, standard methods of analysis such as the t-test and linear regression that assume Normality and constant variance may not be appropriate. For this reason, conventional statistical advice would suggest that non-parametric methods be used to analyse HRQoL data. The bootstrap is one such computer intensive non-parametric method for analysing data. We used the bootstrap for hypothesis testing and the estimation of standard errors and confidence intervals for parameters, in four datasets (which illustrate the different aspects of study design. We then compared and contrasted the bootstrap with standard methods of analysing HRQoL outcomes. The standard methods included t-tests, linear regression, summary measures and General Linear Models. Overall, in the datasets we studied, using the SF-36 outcome, bootstrap methods produce results similar to conventional statistical methods. This is likely because the t-test and linear regression are robust to the violations of assumptions that HRQoL data are likely to cause (i.e. non-Normality. While particular to our datasets, these findings are likely to generalise to other HRQoL outcomes, which have discrete, bounded and skewed distributions. Future research with other HRQoL outcome measures, interventions and populations, is required to

  17. Non-standard finite difference and Chebyshev collocation methods for solving fractional diffusion equation

    Science.gov (United States)

    Agarwal, P.; El-Sayed, A. A.

    2018-06-01

    In this paper, a new numerical technique for solving the fractional order diffusion equation is introduced. This technique basically depends on the Non-Standard finite difference method (NSFD) and Chebyshev collocation method, where the fractional derivatives are described in terms of the Caputo sense. The Chebyshev collocation method with the (NSFD) method is used to convert the problem into a system of algebraic equations. These equations solved numerically using Newton's iteration method. The applicability, reliability, and efficiency of the presented technique are demonstrated through some given numerical examples.

  18. Assessing the reliability of the borderline regression method as a standard setting procedure for objective structured clinical examination

    Directory of Open Access Journals (Sweden)

    Sara Mortaz Hejri

    2013-01-01

    Full Text Available Background: One of the methods used for standard setting is the borderline regression method (BRM. This study aims to assess the reliability of BRM when the pass-fail standard in an objective structured clinical examination (OSCE was calculated by averaging the BRM standards obtained for each station separately. Materials and Methods: In nine stations of the OSCE with direct observation the examiners gave each student a checklist score and a global score. Using a linear regression model for each station, we calculated the checklist score cut-off on the regression equation for the global scale cut-off set at 2. The OSCE pass-fail standard was defined as the average of all station′s standard. To determine the reliability, the root mean square error (RMSE was calculated. The R2 coefficient and the inter-grade discrimination were calculated to assess the quality of OSCE. Results: The mean total test score was 60.78. The OSCE pass-fail standard and its RMSE were 47.37 and 0.55, respectively. The R2 coefficients ranged from 0.44 to 0.79. The inter-grade discrimination score varied greatly among stations. Conclusion: The RMSE of the standard was very small indicating that BRM is a reliable method of setting standard for OSCE, which has the advantage of providing data for quality assurance.

  19. Challenging the 3.0 GPA Eligibility Standard for Public Relations Internships.

    Science.gov (United States)

    Maynard, Michael L.

    1999-01-01

    Analyzes the appropriateness of a 3.0 GPA standard for public relations internship eligibility at one university. Seeks to determine at what GPA cutoff faculty can feel confident that the student will gain from the internship without damaging the program's reputation. Finds students with a 2.7 GPA did as well as students with GPAs ranging from 3.0…

  20. Design of a new torque standard machine based on a torque generation method using electromagnetic force

    International Nuclear Information System (INIS)

    Nishino, Atsuhiro; Ueda, Kazunaga; Fujii, Kenichi

    2017-01-01

    To allow the application of torque standards in various industries, we have been developing torque standard machines based on a lever deadweight system, i.e. a torque generation method using gravity. However, this method is not suitable for expanding the low end of the torque range, because of the limitations to the sizes of the weights and moment arms. In this study, the working principle of the torque generation method using an electromagnetic force was investigated by referring to watt balance experiments used for the redefinition of the kilogram. Applying this principle to a rotating coordinate system, an electromagnetic force type torque standard machine was designed and prototyped. It was experimentally demonstrated that SI-traceable torque could be generated by converting electrical power to mechanical power. Thus, for the first time, SI-traceable torque was successfully realized using a method other than that based on the force of gravity. (paper)

  1. Application of the 4 pigammaMethod to the Absolute Standardization of Radioactive Sources of Positron Emitters

    International Nuclear Information System (INIS)

    Peyres Medina, V.; Garcia-Torano Martinez, E.; Roteta Ibarra, M.

    2006-01-01

    We discuss the application of the method known as 4 p i g amma c ounting t o the standardization of positron emitters. Monte Carlo simulations are used to calculate the detection efficiency of positrons emitted by the nuclides 22Na and 18F. Two experimental setups are used, both based on a NaI(Tl) well detector. The results of the standardizations are in good agreement with those obtained by other methods. It is shown that the 4 p i g amma m ethod can be successfully used for the absolute standardization of sources of positron emitters. (Author) 23 refs

  2. Relationship between non-standard work arrangements and work-related accident absence in Belgium.

    Science.gov (United States)

    Alali, Hanan; Braeckman, Lutgart; Van Hecke, Tanja; De Clercq, Bart; Janssens, Heidi; Wahab, Magd Abdel

    2017-03-28

    The main objective of this study is to examine the relationship between indicators of non-standard work arrangements, including precarious contract, long working hours, multiple jobs, shift work, and work-related accident absence, using a representative Belgian sample and considering several socio-demographic and work characteristics. This study was based on the data of the fifth European Working Conditions Survey (EWCS). For the analysis, the sample was restricted to 3343 respondents from Belgium who were all employed workers. The associations between non-standard work arrangements and work-related accident absence were studied with multivariate logistic regression modeling techniques while adjusting for several confounders. During the last 12 months, about 11.7% of workers were absent from work because of work-related accident. A multivariate regression model showed an increased injury risk for those performing shift work (OR 1.546, 95% CI 1.074-2.224). The relationship between contract type and occupational injuries was not significant (OR 1.163, 95% CI 0.739-1.831). Furthermore, no statistically significant differences were observed for those performing long working hours (OR 1.217, 95% CI 0.638-2.321) and those performing multiple jobs (OR 1.361, 95% CI 0.827-2.240) in relation to work-related accident absence. Those who rated their health as bad, low educated workers, workers from the construction sector, and those exposed to biomechanical exposure (BM) were more frequent victims of work-related accident absence. No significant gender difference was observed. Indicators of non-standard work arrangements under this study, except shift work, were not significantly associated with work-related accident absence. To reduce the burden of occupational injuries, not only risk reduction strategies and interventions are needed but also policy efforts are to be undertaken to limit shift work. In general, preventive measures and more training on the job are needed to

  3. Determination of free acid by standard addition method in potassium thiocyanate

    International Nuclear Information System (INIS)

    1981-01-01

    An analytical method for determination of free acidity in all SRP process solutions has been developed. Free acidity was successfully determined in solutions of nitric acid and the nitrates of aluminum, chromium(III), iron(III), mercury(II), nickel(II), thorium, and uranium(VI), at metal-to-acid ratios <2.5. Sample requirements, instrumentation, and mode of operation are similar to those currently used in the Laboratories Department free acid procedures. The simple procedure would be suitable for automation and microprocessor control. The method consists of two additions of known increments of acid into a solution containing the sample aliquot (10 μmoles free acid) and 10 mL 1M potassium thiocyanate. The potential is determined in the initial solution and after each addition with a glass electrode and pH meter. The sample concentration is calculated by solution of three simultaneous Nernst equations. Two programs for this iterative computation are available: one written for the PDP-15 computer and another for a Hewlett-Packard 67 (or 97) programmable calculator. The accuracy of the result is verified by a slope that approximates the theoretical Nernst value. The relative standard deviation is <2.5%. This memorandum includes a survey of experiments with thermometric, pH, and Gran plot titrations in a variety of complexants, from which this particular system and technique logically evolved. The appendix includes a literature survey of sixty references, a discussion of the basic measurements, and a complete analytical procedure. The final step for completion of this RTA is training and consultation at the convenience of the Laboratories Department for demonstration of the method with process samples

  4. Experimental use of two standard tick collection methods to evaluate the relative effectiveness of several plant-derived and synthetic repellents against Ixodes scapularis and Amblyomma americanum (Acari: Ixodidae).

    Science.gov (United States)

    Schulze, Terry L; Jordan, Robert A; Dolan, Marc C

    2011-12-01

    We used two standard tick collection methods to test the relative effectiveness of two natural product compounds (nootkatone and carvacrol, classified as an eremophilene sesquiterpene and a monoterpene, respectively, that are derived from botanical sources) with commercially-available plant-derived (EcoSMART Organic Insect Repellent, comprised of plant essential oils) and permethrin-based (Repel Permanone) repellents against Ixodes scapularis Say and Amblyomma americanum (L.). Cloth drags were equally effective in sampling both species of host-seeking nymphs, whereas CO, traps attracted primarily A. americanum. All four repellents performed well on drags, with nootkatone and Permanone Repel (100% repelled through 14 d) slightly more effective than carvacrol and EcoSMART (90.7% and 97.7% repelled at 14 d, respectively) at repelling I. scapularis nymphs. Although the same trend in percent repellency was noted in the CO2 trap trial against both A. americanum nymphs and adults, EcoSMART outperformed Permanone in repelling A. Americanum nymphs after 14 d in the drag trial. Generally, the effectiveness of all repellents tested declined over time. The use of tick drags and CO2 traps was rapid, inexpensive, and easy to use in determining the relative effectiveness of repellents in the field.

  5. Smart density: A more accurate method of measuring rural residential density for health-related research.

    Science.gov (United States)

    Owens, Peter M; Titus-Ernstoff, Linda; Gibson, Lucinda; Beach, Michael L; Beauregard, Sandy; Dalton, Madeline A

    2010-02-12

    Studies involving the built environment have typically relied on US Census data to measure residential density. However, census geographic units are often unsuited to health-related research, especially in rural areas where development is clustered and discontinuous. We evaluated the accuracy of both standard census methods and alternative GIS-based methods to measure rural density. We compared residential density (units/acre) in 335 Vermont school neighborhoods using conventional census geographic units (tract, block group and block) with two GIS buffer measures: a 1-kilometer (km) circle around the school and a 1-km circle intersected with a 100-meter (m) road-network buffer. The accuracy of each method was validated against the actual residential density for each neighborhood based on the Vermont e911 database, which provides an exact geo-location for all residential structures in the state. Standard census measures underestimate residential density in rural areas. In addition, the degree of error is inconsistent so even the relative rank of neighborhood densities varies across census measures. Census measures explain only 61% to 66% of the variation in actual residential density. In contrast, GIS buffer measures explain approximately 90% of the variation. Combining a 1-km circle with a road-network buffer provides the closest approximation of actual residential density. Residential density based on census units can mask clusters of development in rural areas and distort associations between residential density and health-related behaviors and outcomes. GIS-defined buffers, including a 1-km circle and a road-network buffer, can be used in conjunction with census data to obtain a more accurate measure of residential density.

  6. Standard Test Methods for Insulation Integrity and Ground Path Continuity of Photovoltaic Modules

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2000-01-01

    1.1 These test methods cover procedures for (1) testing for current leakage between the electrical circuit of a photovoltaic module and its external components while a user-specified voltage is applied and (2) for testing for possible module insulation breakdown (dielectric voltage withstand test). 1.2 A procedure is described for measuring the insulation resistance between the electrical circuit of a photovoltaic module and its external components (insulation resistance test). 1.3 A procedure is provided for verifying that electrical continuity exists between the exposed external conductive surfaces of the module, such as the frame, structural members, or edge closures, and its grounding point (ground path continuity test). 1.4 This test method does not establish pass or fail levels. The determination of acceptable or unacceptable results is beyond the scope of this test method. 1.5 There is no similar or equivalent ISO standard. This standard does not purport to address all of the safety concerns, if a...

  7. Stability-indicating UPLC method for determining related substances and degradants in dronedarone.

    Science.gov (United States)

    Pydimarry, Surya Prakash Rao; Cholleti, Vijay Kumar; Vangala, Ranga Reddy

    2014-08-01

    A simple, sensitive and reproducible method was developed on ultra-performance liquid chromatography coupled with photodiode array detection for the quantitative determination of dronedarone hydrochloride (DRO) in drug substance and pharmaceutical dosage forms. The method is applicable for the quantification of related substances and assays of drug substances. Chromatographic separation was achieved on Acquity UPLC BEH C8 100 mm, 2.1 mm and 1.7 µm columns, using gradient elution within a short run time of 10.0 min. The eluted compounds were monitored at 288 nm, the flow rate was 0.5 mL/min and the column oven temperature was maintained at 40°C. The resolution of DRO and 11 impurities (potentials and by-products) was greater than 2.0 for all pairs of components. The high correlation coefficient value (>0.9995) indicates the clear correlations between the concentrations of investigated compound and their peak areas within the test ranges. The repeatability and intermediate precision, expressed by the relative standard deviation, were less than 2.5%. The accuracy and validity of the method were further ascertained by performing recovery studies via a spike method. The accuracy of the method, expressed as relative error, was satisfactory. No interference was observed from concomitant substances normally added to the tablets. DRO was subjected to the stress conditions of oxidative, acid, base, hydrolytic, thermal and photolytic degradation. DRO was found to degrade significantly in acid and base stress conditions and to remain stable in thermal, photolytic degradation, oxidative and hydrolytic conditions. The degradation products were well resolved from primary peak and its impurities, proving that the method is stability indicating. The developed method was validated as per International Conference on Harmonization guidelines with respect to specificity, limit of detection, limit of quantification, linearity, accuracy, precision, solution stability and robustness

  8. Multigrid techniques with non-standard coarsening and group relaxation methods

    International Nuclear Information System (INIS)

    Danaee, A.

    1989-06-01

    In the usual (standard) multigrid methods, doubling of grid sizes with different smoothing iterations (pointwise, or blockwise) has been considered by different authors. Some have indicated that a large coarsening can also be used, but is not beneficial (cf. H3, p.59). In this paper, it is shown that with a suitable blockwise smoothing scheme, some advantages could be achieved even with a factor of H l-1 /h l = 3. (author). 10 refs, 2 figs, 6 tabs

  9. A review of the quantum current standard

    International Nuclear Information System (INIS)

    Kaneko, Nobu-Hisa; Nakamura, Shuji; Okazaki, Yuma

    2016-01-01

    The electric current, voltage, and resistance standards are the most important standards related to electricity and magnetism. Of these three standards, only the ampere, which is the unit of electric current, is an International System of Units (SI) base unit. However, even with modern technology, relatively large uncertainty exists regarding the generation and measurement of current. As a result of various innovative techniques based on nanotechnology and novel materials, new types of junctions for quantum current generation and single-electron current sources have recently been proposed. These newly developed methods are also being used to investigate the consistency of the three quantum electrical effects, i.e. the Josephson, quantum Hall, and single-electron tunneling effects, which are also known as ‘the quantum metrology triangle’. This article describes recent research and related developments regarding current standards and quantum-metrology-triangle experiments. (topical review)

  10. Comparison of Standard Culture-Based Method to Culture-Independent Method for Evaluation of Hygiene Effects on the Hand Microbiome

    Science.gov (United States)

    Leff, J.; Henley, J.; Tittl, J.; De Nardo, E.; Butler, M.; Griggs, R.; Fierer, N.

    2017-01-01

    ABSTRACT Hands play a critical role in the transmission of microbiota on one’s own body, between individuals, and on environmental surfaces. Effectively measuring the composition of the hand microbiome is important to hand hygiene science, which has implications for human health. Hand hygiene products are evaluated using standard culture-based methods, but standard test methods for culture-independent microbiome characterization are lacking. We sampled the hands of 50 participants using swab-based and glove-based methods prior to and following four hand hygiene treatments (using a nonantimicrobial hand wash, alcohol-based hand sanitizer [ABHS], a 70% ethanol solution, or tap water). We compared results among culture plate counts, 16S rRNA gene sequencing of DNA extracted directly from hands, and sequencing of DNA extracted from culture plates. Glove-based sampling yielded higher numbers of unique operational taxonomic units (OTUs) but had less diversity in bacterial community composition than swab-based sampling. We detected treatment-induced changes in diversity only by using swab-based samples (P hand hygiene industry methods and for future hand microbiome studies. On the basis of our results and previously published studies, we propose recommendations for best practices in hand microbiome research. PMID:28351915

  11. Standard Test Methods for Measurement of Electrical Performance and Spectral Response of Nonconcentrator Multijunction Photovoltaic Cells and Modules

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 These test methods provide special techniques needed to determine the electrical performance and spectral response of two-terminal, multijunction photovoltaic (PV) devices, both cell and modules. 1.2 These test methods are modifications and extensions of the procedures for single-junction devices defined by Test Methods E948, E1021, and E1036. 1.3 These test methods do not include temperature and irradiance corrections for spectral response and current-voltage (I-V) measurements. Procedures for such corrections are available in Test Methods E948, E1021, and E1036. 1.4 These test methods may be applied to cells and modules intended for concentrator applications. 1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and ...

  12. Comparison between the triglycerides standardization of routine methods used in Japan and the chromotropic acid reference measurement procedure used by the CDC Lipid Standardization Programme.

    Science.gov (United States)

    Nakamura, Masakazu; Iso, Hiroyasu; Kitamura, Akihiko; Imano, Hironori; Noda, Hiroyuki; Kiyama, Masahiko; Sato, Shinichi; Yamagishi, Kazumasa; Nishimura, Kunihiro; Nakai, Michikazu; Vesper, Hubert W; Teramoto, Tamio; Miyamoto, Yoshihiro

    2016-11-01

    Background The US Centers for Disease Control and Prevention ensured adequate performance of the routine triglycerides methods used in Japan by a chromotropic acid reference measurement procedure used by the Centers for Disease Control and Prevention lipid standardization programme as a reference point. We examined standardized data to clarify the performance of routine triglycerides methods. Methods The two routine triglycerides methods were the fluorometric method of Kessler and Lederer and the enzymatic method. The methods were standardized using 495 Centers for Disease Control and Prevention reference pools with 98 different concentrations ranging between 0.37 and 5.15 mmol/L in 141 survey runs. The triglycerides criteria for laboratories which perform triglycerides analyses are used: accuracy, as bias ≤5% from the Centers for Disease Control and Prevention reference value and precision, as measured by CV, ≤5%. Results The correlation of the bias of both methods to the Centers for Disease Control and Prevention reference method was: y (%bias) = 0.516 × (Centers for Disease Control and Prevention reference value) -1.292 ( n = 495, R 2  = 0.018). Triglycerides bias at medical decision points of 1.13, 1.69 and 2.26 mmol/L was -0.71%, -0.42% and -0.13%, respectively. For the combined precision, the equation y (CV) = -0.398 × (triglycerides value) + 1.797 ( n = 495, R 2  = 0.081) was used. Precision was 1.35%, 1.12% and 0.90%, respectively. It was shown that triglycerides measurements at Osaka were stable for 36 years. Conclusions The epidemiologic laboratory in Japan met acceptable accuracy goals for 88.7% of all samples, and met acceptable precision goals for 97.8% of all samples measured through the Centers for Disease Control and Prevention lipid standardization programme and demonstrated stable results for an extended period of time.

  13. Informatics and Standards for Nanomedicine Technology

    Science.gov (United States)

    Thomas, Dennis G.; Klaessig, Fred; Harper, Stacey L.; Fritts, Martin; Hoover, Mark D.; Gaheen, Sharon; Stokes, Todd H.; Reznik-Zellen, Rebecca; Freund, Elaine T.; Klemm, Juli D.; Paik, David S.; Baker, Nathan A.

    2011-01-01

    There are several issues to be addressed concerning the management and effective use of information (or data), generated from nanotechnology studies in biomedical research and medicine. These data are large in volume, diverse in content, and are beset with gaps and ambiguities in the description and characterization of nanomaterials. In this work, we have reviewed three areas of nanomedicine informatics: information resources; taxonomies, controlled vocabularies, and ontologies; and information standards. Informatics methods and standards in each of these areas are critical for enabling collaboration, data sharing, unambiguous representation and interpretation of data, semantic (meaningful) search and integration of data; and for ensuring data quality, reliability, and reproducibility. In particular, we have considered four types of information standards in this review, which are standard characterization protocols, common terminology standards, minimum information standards, and standard data communication (exchange) formats. Currently, due to gaps and ambiguities in the data, it is also difficult to apply computational methods and machine learning techniques to analyze, interpret and recognize patterns in data that are high dimensional in nature, and also to relate variations in nanomaterial properties to variations in their chemical composition, synthesis, characterization protocols, etc. Progress towards resolving the issues of information management in nanomedicine using informatics methods and standards discussed in this review will be essential to the rapidly growing field of nanomedicine informatics. PMID:21721140

  14. Recent Japanese Industrial Standards concerned with radiological monitors

    International Nuclear Information System (INIS)

    Katoh, Akira

    1983-01-01

    JIS has achieved large role to keep the quality and performance of products above certain levels and to assure the uniformity and interchangeability. The JIS in radiation field is roughly divided into that of radiation measurement and that of X-ray generators, and there were about 90 standards as of the end of March, 1983. The equipment related to radiation is large variety, small quantity products, and highly technical compound products. For the inspection and test, special instruments are required. Though some merchandise related to radiation is specified to indicate JIS marks, actually there is not anything that obtained the approval. The JIS related to radiation can be said the recommendation standards, and it is a feature that the standards of software are regarded as important. Two or three drafts of new JIS related mainly to environmental gamma-ray monitoring and X-ray equipment have been drawn up every year. Here, the JIS regarding radiation measurement, which is published after March 1, 1983, is outlined. The method of establishing JIS, JIS published or expected to be published, JIS of hardware and software, the contents of four standards, that is, environmental gamma-ray continuous monitor, method of its calibration, thermo-luminescence dosimeter and survey meter for X-ray and gamma-ray, the international standards and so on are reported. (Kako, I.)

  15. Proportions of Maxillary Anterior Teeth Relative to Each Other and to Golden Standard in Tabriz Dental Faculty Students

    OpenAIRE

    Fereydoun Parnia; Ali Hafezeqoran; Farhang Mahboub; Elnaz Moslehifard; Rodabeh Koodaryan; Rosa Moteyagheni; Fariba Saleh Saber

    2010-01-01

    Background and aims. Various methods are used to measure the size and form of the teeth, including the golden proportion, and the width-to-length ratio of central teeth, referred to as the golden standard. The aim of this study was to evaluate the occurrence of golden standard values and golden proportion in the anterior teeth. Materials and methods. Photographs of 100 dentistry students (50 males and 50 females) were taken under standard conditions. The visible widths and lengths...

  16. Comparison of PCR with Standard Method (MPN for detection of bacterial contamination in drinking water

    Directory of Open Access Journals (Sweden)

    Fatemeh Dehghan

    2014-11-01

    Full Text Available Background: Detection of bacterial contamination in drinking water by culture method is a time and cost consuming method and spends a few days depending on contamination degree. However, the people use the tap water during that time. Molecular methods are rapid and sensitive. In this study a rapid Multiplex PCR method was used for rapid analysis both coliform bacteria and E.coli, and probable detection of VBNC bacteria in drinking water, the experiments were performed in bacteriological lab of water and Wastewater Corporation in Markazi province. Material and Methods:Amplification of a fragment from each of lacZ and uidA genes in a Multiplex PCR was used for detection of coliforms. Eight samples was taken from Arak drinking water system including 36 samples of wells, 41 samples of water distribution network and 3 samples from water storages were examined by amplification of lacZ and uidA genes in a Multiplex PCR. Equivalently, the MPN test was applied as a standard method for all samples for comparison of results. Standard bacteria, pure bacteria isolated from positive MPN and CRM were examined by PCR and MPN method. Results: The result of most samples water network, water storages, and water well were same in both MPN and PCR method .The results of standard bacteria and pure cultures of bacteria isolated from positive MPN and CRM confirmed the PCR method. Five samples were positive in PCR but negative in MPN method. Duration time of PCR was decreased about 105 min by changing the PCR program and electrophoreses factors. Conclusion: The Multiplex PCR can detect coliform bacteria and E.coli synchronous in drinking water.

  17. Selection and evaluation of gamma decay standards for detector calibration using coincidence method

    International Nuclear Information System (INIS)

    Hlavac, S.

    2000-01-01

    Coincidence method for calibration of gamma detectors using suitable calibration standards with two cascading gamma rays is analyzed. From the list of recommended gamma ray standards currently under reevaluation by the CRP, 14 radionuclides were selected as the potential source candidates for the coincidence method. The following sources were selected 24 Na, 46 Sc, 60 Co, 66 Ga, 75 Se, 88 Y, Nb 94 , 111 In, 123m Te, 133 Ba, 134 Cs, 152 Eu, 154 Eu and 207 Bi. Reaction 11 B (p,γ) 12 C* was also selected as a source of high energy gamma rays. Experimental data on angular correlation coefficients for selected sources were collected from the literature and evaluated according to the recommended procedure. Theoretical angular correlation coefficients were calculated and compared to the evaluated data. (author)

  18. Using Standard-Sole Cost Method for Performance Gestion Accounting and Calculation Cost in the Machine Building Industry

    Directory of Open Access Journals (Sweden)

    Cleopatra Sendroiu

    2006-07-01

    Full Text Available The main purpose of improving and varying cost calculation methods in the machine building industry is to make them more operational and efficient in supplying the information necessary to the management in taking its decisions. The present cost calculation methods used in the machine building plants - global method and the method per orders - by which a historical cost is determined a posteriori used in deducting and post factum justification of manufacturing expenses does not offer the management the possibility to fully satisfy its need for information. We are talking about a change of conception in applying certain systems, methods and work techniques, according to the needs of efficient administration of production and the plant seen as a whole. The standard-cost method best answers to the needs of the effective management of the value side of the manufacturing process and raising economic efficiency. We consider that, in the machine building industry, these objectives can be achieved by using the standard - sole cost alternative of the standard-cost method.

  19. Using Standard-Sole Cost Method for Performance Gestion Accounting and Calculation Cost in the Machine Building Industry

    Directory of Open Access Journals (Sweden)

    Aureliana Geta Roman

    2006-09-01

    Full Text Available The main purpose of improving and varying cost calculation methods in the machine building industry is to make them more operational and efficient in supplying the information necessary to the management in taking its decisions. The present cost calculation methods used in the machine building plants – global method and the method per orders – by which a historical cost is determined a posteriori used in deducting and post factum justification of manufacturing expenses does not offer the management the possibility to fully satisfy its need for information. We are talking about a change of conception in applying certain systems, methods and work techniques, according to the needs of efficient administration of production and the plant seen as a whole. The standard-cost method best answers to the needs of the effective management of the value side of the manufacturing process and raising economic efficiency. We consider that, in the machine building industry, these objectives can be achieved by using the standard - sole cost alternative of the standard-cost method.

  20. Standard Establishment Through Scenarios (SETS): A new technique for occupational fitness standards.

    Science.gov (United States)

    Blacklock, R E; Reilly, T J; Spivock, M; Newton, P S; Olinek, S M

    2015-01-01

    An objective and scientific task analysis provides the basis for establishing legally defensible Physical Employment Standards (PES), based on common and essential occupational tasks. Infrequent performance of these tasks creates challenges when developing PES based on criterion, or content validity. Develop a systematic approach using Subject Matter Experts (SME) to provide tasks with 1) an occupationally relevant scenario considered common to all personnel; 2) a minimum performance standard defined by time, distance, load or work. Examples provided here relate to the development of a new PES for the Canadian Armed Forces (CAF). SME of various experience are selected based on their eligibility criteria. SME are required to define a reasonable scenario for each task from personal experience, provide occupational performance requirements of the scenario in sub-groups, and discuss and agree by consensus vote on the final standard based on the definition of essential. A common and essential task for the CAF is detailed as a case example of process application. Techniques to avoid common SME rating errors are discussed and advantages to the method described. The SETS method was developed as a systematic approach to setting occupational performance standards and qualifying information from SME.

  1. [Development of a software standardizing optical density with operation settings related to several limitations].

    Science.gov (United States)

    Tu, Xiao-Ming; Zhang, Zuo-Heng; Wan, Cheng; Zheng, Yu; Xu, Jin-Mei; Zhang, Yuan-Yuan; Luo, Jian-Ping; Wu, Hai-Wei

    2012-12-01

    To develop a software that can be used to standardize optical density to normalize the procedures and results of standardization in order to effectively solve several problems generated during standardization of in-direct ELISA results. The software was designed based on the I-STOD method with operation settings to solve the problems that one might encounter during the standardization. Matlab GUI was used as a tool for the development. The software was tested with the results of the detection of sera of persons from schistosomiasis japonica endemic areas. I-STOD V1.0 (WINDOWS XP/WIN 7, 0.5 GB) was successfully developed to standardize optical density. A serial of serum samples from schistosomiasis japonica endemic areas were used to examine the operational effects of I-STOD V1.0 software. The results indicated that the software successfully overcame several problems including reliability of standard curve, applicable scope of samples and determination of dilution for samples outside the scope, so that I-STOD was performed more conveniently and the results of standardization were more consistent. I-STOD V1.0 is a professional software based on I-STOD. It can be easily operated and can effectively standardize the testing results of in-direct ELISA.

  2. Business transactions and standards. Towards a system of concepts and a method for early problem identification in standard implementation projects

    NARCIS (Netherlands)

    Rukanova, B.D.

    2005-01-01

    To summarize, with respect to research question one we constructed a system of concepts, while in answer to research question two we proposed a method of how to apply this system of concepts in practice in order to identify potential problems in early stages of standard implementation projects.

  3. Characterization of an absorbed dose standard in water through ionometric methods

    International Nuclear Information System (INIS)

    Vargas V, M.X.

    2003-01-01

    In this work the unit of absorbed dose at the Secondary Standard Dosimetry Laboratory (SSDL) of Mexico, is characterized by means of the development of a primary standard of absorbed dose to water, D agua . The main purpose is to diminish the uncertainty in the service of dosimetric calibration of ionization chambers (employed in radiotherapy of extemal beams) that offers this laboratory. This thesis is composed of seven chapters: In Chapter 1 the position and justification of the problem is described, as well as the general and specific objectives. In Chapter 2, a presentation of the main quantities and units used in dosimetry is made, in accordance with the recommendations of the International Commission on Radiation Units and Measurements (ICRU) that establish the necessity to have a coherent system with the international system of units and dosimetric quantities. The concepts of equilibrium and transient equilibrium of charged particles (TCPE) are also presented, which are used later in the quantitative determination of D agua . Finally, since the proposed standard of D agua is of ionometric type, an explanation of the Bragg-Gray and Spencer-Attix cavity theories is made. These theories are the foundation of this type of standards. On the other hand, to guarantee the complete validity of the conditions demanded by these theories it is necessary to introduce correction factors. These factors are determined in Chapters 5 and 6. Since for the calculation of the correction factors Monte Carlo (MC) method is used in an important way, in Chapter 3 the fundamental concepts of this method are presented; in particular the principles of the code MCNP4C [Briesmeister 2000] are detailed, making emphasis on the basis of electron transport and variance reduction techniques used in this thesis. Because a phenomenological approach is carried out in the development of the standard of D agua , in Chapter 4 the characteristics of the Picker C/9 unit, the ionization chamber type

  4. Next Generation Science Standards: A National Mixed-Methods Study on Teacher Readiness

    Science.gov (United States)

    Haag, Susan; Megowan, Colleen

    2015-01-01

    Next Generation Science Standards (NGSS) science and engineering practices are ways of eliciting the reasoning and applying foundational ideas in science. As research has revealed barriers to states and schools adopting the NGSS, this mixed-methods study attempts to identify characteristics of professional development (PD) that will support NGSS…

  5. A Study on the Improvement of Safety Testing Standards and Methods for Mammography

    International Nuclear Information System (INIS)

    Choi, Seon Hyeong; Jung, Ah Young; Yong, Hwan Seok; Kim, Do Wan; Jang, Gi Won; Cha, Sang Hoon; Jo, Sang Won; Park, Ji Koon

    2012-01-01

    To establish the improved national safety testing standards and methods for mammography. We investigated and compared the current status of mammographic equipment installation with the national and international safety and quality control programs and methods. We established and verified the draft for safety testing standards and methods. We propose that the investigations of the conductor system, hardware leakage radiation profile, illumination intensity test, comparison between X-ray and light photon exposure, X-ray dose exposure on the chest wall, compression equipment size, timing equipment, and the average effective radiation dose, should all be maintained as they are in the present state without any changes. However, the exposure radiation dose reproducibility, kVp and mAs, and the half value layer tests should be reconsidered and revised. Moreover, compression pressure and autonomic exposure control system (AEC) tests should be included as new criteria. Other parameter controls included in the phantom image analysis which overlap with total quality assurance should be excluded. We recommend that AEC and compression pressure tests should be included as new criteria and the methods for the exposure radiation dose reproducibility, kVp, and mAs, and half value layer tests should be reconsidered and revised.

  6. Standard test method for uranium analysis in natural and waste water by X-ray fluorescence

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2004-01-01

    1.1 This test method applies for the determination of trace uranium content in waste water. It covers concentrations of U between 0.05 mg/L and 2 mg/L. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  7. A Comparison of Kernel Equating and Traditional Equipercentile Equating Methods and the Parametric Bootstrap Methods for Estimating Standard Errors in Equipercentile Equating

    Science.gov (United States)

    Choi, Sae Il

    2009-01-01

    This study used simulation (a) to compare the kernel equating method to traditional equipercentile equating methods under the equivalent-groups (EG) design and the nonequivalent-groups with anchor test (NEAT) design and (b) to apply the parametric bootstrap method for estimating standard errors of equating. A two-parameter logistic item response…

  8. Building America Guidance for Identifying and Overcoming Code, Standard, and Rating Method Barriers

    Energy Technology Data Exchange (ETDEWEB)

    Cole, Pamala C.; Halverson, Mark A.

    2013-09-01

    The U.S. Department of Energy’s (DOE) Building America program implemented a new Codes and Standards Innovation (CSI) Team in 2013. The Team’s mission is to assist Building America (BA) research teams and partners in identifying and resolving conflicts between Building America innovations and the various codes and standards that govern the construction of residences. A CSI Roadmap was completed in September, 2013. This guidance document was prepared using the information in the CSI Roadmap to provide BA research teams and partners with specific information and approaches to identifying and overcoming potential barriers to Building America (BA) innovations arising in and/or stemming from codes, standards, and rating methods. For more information on the BA CSI team, please email: CSITeam@pnnl.gov

  9. A novel method for standardized application of fungal spore coatings for mosquito exposure bioassays

    Directory of Open Access Journals (Sweden)

    Knols Bart GJ

    2010-01-01

    Full Text Available Abstract Background Interest in the use of fungal entomopathogens against malaria vectors is growing. Fungal spores infect insects via the cuticle and can be applied directly on the insect to evaluate infectivity. For flying insects such as mosquitoes, however, application of fungal suspensions on resting surfaces is more realistic and representative of field settings. For this type of exposure, it is essential to apply specific amounts of fungal spores homogeneously over a surface for testing the effects of fungal dose and exposure time. Contemporary methods such as spraying or brushing spore suspensions onto substrates do not produce the uniformity and consistency that standardized laboratory assays require. Two novel fungus application methods using equipment developed in the paint industry are presented and compared. Methods Wired, stainless steel K-bars were tested and optimized for coating fungal spore suspensions onto paper substrates. Different solvents and substrates were evaluated. Two types of coating techniques were compared, i.e. manual and automated coating. A standardized bioassay set-up was designed for testing coated spores against malaria mosquitoes. Results K-bar coating provided consistent applications of spore layers onto paper substrates. Viscous Ondina oil formulations were not suitable and significantly reduced spore infectivity. Evaporative Shellsol T solvent dried quickly and resulted in high spore infectivity to mosquitoes. Smooth proofing papers were the most effective substrate and showed higher infectivity than cardboard substrates. Manually and mechanically applied spore coatings showed similar and reproducible effects on mosquito survival. The standardized mosquito exposure bioassay was effective and consistent in measuring effects of fungal dose and exposure time. Conclusions K-bar coating is a simple and consistent method for applying fungal spore suspensions onto paper substrates and can produce coating layers

  10. Paediatric rehabilitation treatment standards: a method for quality assurance in Germany

    Directory of Open Access Journals (Sweden)

    Jutta Ahnert

    2014-07-01

    Full Text Available Over the last few years, the German Pension Insurance has implemented a new method of quality assurance for inpatient rehabilitation of children and adolescents diagnosed with bronchial asthma, obesity, or atopic dermatitis: the so-called rehabilitation treatment standards (RTS. They aim at promoting a comprehensive and evidence-based care in rehabilitation. Furthermore, they are intended to make the therapeutic processes in medical rehabilitation as well as potential deficits more transparent. The development of RTS was composed of five phases during which current scientific evidence, expert knowledge, and patient expectations were included. Their core element is the specification of evidence-based treatment modules that describe a good rehabilitation standard for children diagnosed with bronchial asthma, obesity, or atopic dermatitis. Opportunities and limitations of the RTS as a tool for quality assurance are discussed.

  11. Standard Test Method for Sizing and Counting Particulate Contaminant In and On Clean Room Garments

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2000-01-01

    1.1 This test method covers the determination of detachable particulate contaminant 5 m or larger, in and on the fabric of clean room garments. 1.2 This test method does not apply to nonporous fabrics such as Tyvek or Gortex. It only applies to fabrics that are porous such as cotton or polyester. 1.3 The values stated in SI units are to be regarded as the standard. The inch-pound values given in parentheses are for information only. 1.4 This test method provides not only the traditional optical microscopic analysis but also a size distribution and surface obscuration analysis for particles on a fine-textured membrane filter or in a tape lift sample. It utilizes transmitted illumination to render all particles darker than the background for gray level detection. Particles collected on opaque plates must be transferred to a suitable membrane filter. This standard may involve hazardous materials, operations, and equipment. This standard does not purport to address all of the safety concerns, if any, associat...

  12. Standardization of method to determine 241Pu in urine samples by liquid scintillation analyzer

    International Nuclear Information System (INIS)

    Raveendran, Nanda; Rao, D.D.; Yadav, J.R.; Baburajan, A.

    2015-01-01

    As a part of radiation protection programme, occupational workers of fuel reprocessing plant are checked for internal contamination by analyzing urine samples periodically. Urine samples are analyzed to determine 239+240 Pu and 238 Pu by using standard conventional method and are counted by alpha spectrometry. 241 Pu is also one of the contaminant present in the urine sample of radiation workers. It is a low beta emitter with E max 21 keV. A methodology for the determination of this nuclide was standardized by using radiochemical analysis followed by Liquid Scintillation Counting. The method was tested and found suitable for the determination of 241 Pu in urine sample for the assessment of Committed Effective Dose (CED). (author)

  13. Standard test method for initial screening of corrosion inhibiting admixtures for steel in concrete

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2007-01-01

    1.1 This test method covers a procedure for determining the effects of chemical admixtures on the corrosion of metals in concrete. This test method can be used to evaluate materials intended to inhibit chloride-induced corrosion of steel in concrete. It can also be used to evaluate the corrosivity of admixtures by themselves or in a chloride environment. This test is not applicable for emulsions. 1.2 &solely-SI-units; 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  14. The Scalable Coherent Interface and related standards projects

    International Nuclear Information System (INIS)

    Gustavson, D.B.

    1991-09-01

    The Scalable Coherent Interface (SCI) project (IEEE P1596) found a way to avoid the limits that are inherent in bus technology. SCI provides bus-like services by transmitting packets on a collection of point-to-point unidirectional links. The SCI protocols support cache coherence in a distributed-shared-memory multiprocessor model, message passing, I/O, and local-area-network-like communication over fiber optic or wire links. VLSI circuits that operate parallel links at 1000 MByte/s and serial links at 1000 Mbit/s will be available early in 1992. Several ongoing SCI-related projects are applying the SCI technology to new areas or extending it to more difficult problems. P1596.1 defines the architecture of a bridge between SCI and VME; P1596.2 compatibly extends the cache coherence mechanism for efficient operation with kiloprocessor systems; P1596.3 defines new low-voltage (about 0.25 V) differential signals suitable for low power interfaces for CMOS or GaAs VLSI implementations of SCI; P1596.4 defines a high performance memory chip interface using these signals; P1596.5 defines data transfer formats for efficient interprocessor communication in heterogeneous multiprocessor systems. This paper reports the current status of SCI, related standards, and new projects. 16 refs

  15. Quantitative autoradiography of semiconductor materials by means of diffused phosphorus standards

    International Nuclear Information System (INIS)

    Treutler, H.C.; Freyer, K.

    1983-01-01

    A suitable standard sample was developed and tested on the basis of phosphorus for the quantitative autoradiography of elements of interest in semiconductor technology. By the aid of silicon disks with a phosphorus concentration of 6x10 17 atomsxcm - 2 the error of the quantitative autoradiogprahic method is determined. The relative mean error of the density measurement is at best +-4%; the relative mean error of the determination of phosphorus concentration by use of an error-free standard sample is about +-15%. The method will be extended to other elements by use of this standard sample of phosphorus. (author)

  16. Quantitative determination and validation of octreotide acetate using 1 H-NMR spectroscopy with internal standard method.

    Science.gov (United States)

    Yu, Chen; Zhang, Qian; Xu, Peng-Yao; Bai, Yin; Shen, Wen-Bin; Di, Bin; Su, Meng-Xiang

    2018-01-01

    Quantitative nuclear magnetic resonance (qNMR) is a well-established technique in quantitative analysis. We presented a validated 1 H-qNMR method for assay of octreotide acetate, a kind of cyclic octopeptide. Deuterium oxide was used to remove the undesired exchangeable peaks, which was referred to as proton exchange, in order to make the quantitative signals isolated in the crowded spectrum of the peptide and ensure precise quantitative analysis. Gemcitabine hydrochloride was chosen as the suitable internal standard. Experimental conditions, including relaxation delay time, the numbers of scans, and pulse angle, were optimized first. Then method validation was carried out in terms of selectivity, stability, linearity, precision, and robustness. The assay result was compared with that by means of high performance liquid chromatography, which is provided by Chinese Pharmacopoeia. The statistical F test, Student's t test, and nonparametric test at 95% confidence level indicate that there was no significant difference between these two methods. qNMR is a simple and accurate quantitative tool with no need for specific corresponding reference standards. It has the potential of the quantitative analysis of other peptide drugs and standardization of the corresponding reference standards. Copyright © 2017 John Wiley & Sons, Ltd.

  17. New clinical validation method for automated sphygmomanometer: a proposal by Japan ISO-WG for sphygmomanometer standard.

    Science.gov (United States)

    Shirasaki, Osamu; Asou, Yosuke; Takahashi, Yukio

    2007-12-01

    Owing to fast or stepwise cuff deflation, or measuring at places other than the upper arm, the clinical accuracy of most recent automated sphygmomanometers (auto-BPMs) cannot be validated by one-arm simultaneous comparison, which would be the only accurate validation method based on auscultation. Two main alternative methods are provided by current standards, that is, two-arm simultaneous comparison (method 1) and one-arm sequential comparison (method 2); however, the accuracy of these validation methods might not be sufficient to compensate for the suspicious accuracy in lateral blood pressure (BP) differences (LD) and/or BP variations (BPV) between the device and reference readings. Thus, the Japan ISO-WG for sphygmomanometer standards has been studying a new method that might improve validation accuracy (method 3). The purpose of this study is to determine the appropriateness of method 3 by comparing immunity to LD and BPV with those of the current validation methods (methods 1 and 2). The validation accuracy of the above three methods was assessed in human participants [N=120, 45+/-15.3 years (mean+/-SD)]. An oscillometric automated monitor, Omron HEM-762, was used as the tested device. When compared with the others, methods 1 and 3 showed a smaller intra-individual standard deviation of device error (SD1), suggesting their higher reproducibility of validation. The SD1 by method 2 (P=0.004) significantly correlated with the participant's BP, supporting our hypothesis that the increased SD of device error by method 2 is at least partially caused by essential BPV. Method 3 showed a significantly (P=0.0044) smaller interparticipant SD of device error (SD2), suggesting its higher interparticipant consistency of validation. Among the methods of validation of the clinical accuracy of auto-BPMs, method 3, which showed the highest reproducibility and highest interparticipant consistency, can be proposed as being the most appropriate.

  18. Standard Test Method for Dust Erosion Resistance of Optical and Infrared Transparent Materials and Coatings

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2005-01-01

    1.1 This test method covers the resistance of transparent plastics and coatings used in aerospace windscreens, canopies, and viewports to surface erosion as a result of dust impingement. This test method simulates flight through a defined particle cloud environment by means of independent control of particle size, velocity, impact angle, mass loading, and test duration. 1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  19. Condition Assessment Survey (CAS) Program. Deficiency standards and inspections methods manual: Volume 6, 0.06 Interior construction

    Energy Technology Data Exchange (ETDEWEB)

    1993-05-01

    General information is presented for asset determinant factor/CAS repair codes/CAS cost factors; guide sheet tool & material listing; testing methods; inspection frequency; standard system design life tables; system work breakdown structure; and general system/material data. Deficiency standards and inspection methods are presented for conventional and specialty partitions, toilet partitions & accessories, interior doors, paint finishes/coatings/ wall covering systems; floor finishing systems; and ceiling systems.

  20. Condition Assessment Survey (CAS) Program. Deficiency standards and inspections methods manual: Volume 11, 0.11 Specialty systems

    Energy Technology Data Exchange (ETDEWEB)

    1993-05-01

    General information is presented for asset determinant factor/CAS repair codes/CAS cost factors; guide sheet tool & material listing; testing methods; inspection frequency; standard system design life tables; system work breakdown structure; and general system/material data. Deficiency standards and inspection methods are presented for canopies; loading dock systems; tanks; domes (bulk storage, metal framing); louvers & vents; access floors; integrated ceilings; and mezzanine structures.

  1. Standard test method for radiochemical determination of uranium isotopes in soil by alpha spectrometry

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2011-01-01

    1.1 This test method covers the determination of alpha-emitting uranium isotopes in soil. This test method describes one acceptable approach to the determination of uranium isotopes in soil. 1.2 The test method is designed to analyze 10 g of soil; however, the sample size may be varied to 50 g depending on the activity level. This test method may not be able to completely dissolve all forms of uranium in the soil matrix. Studies have indicated that the use of hydrofluoric acid to dissolve soil has resulted in lower values than results using total dissolution by fusion. 1.3 The lower limit of detection is dependent on count time, sample size, detector, background, and tracer yield. The chemical yield averaged 78 % in a single laboratory evaluation, and 66 % in an interlaboratory collaborative study. 1.4 The values stated in SI units are to be regarded as standard. The values given in parentheses are for information only. 1.5 This standard does not purport to address all of the safety concerns, if any, ass...

  2. A Standardized Algorithm for Determining the Underlying Cause of Death in HIV Infection as AIDS or non-AIDS Related: Results from the EuroSIDA Study

    DEFF Research Database (Denmark)

    Kowalska, Justyna D; Mocroft, Amanda; Ledergerber, Bruno

    2011-01-01

    are a natural consequence of an increased awareness and knowledge in the field. To monitor and analyze changes in mortality over time, we have explored this issue within the EuroSIDA study and propose a standardized protocol unifying data collected and allowing for classification of all deaths as AIDS or non......-AIDS related, including events with missing cause of death. Methods: Several classifications of the underlying cause of death as AIDS or non-AIDS related within the EuroSIDA study were compared: central classification (CC-reference group) based on an externally standardised method (the CoDe procedures), local...

  3. Comparison study for the CCME reference method for determination of PHC in soil by using internal and external standard methods and by using silica gel column cleanup and in-situ silica gel cleanup methods

    International Nuclear Information System (INIS)

    Wang, Z.; Fingas, M.; Sigouin, L.; Yang, C.; Hollebone, B.

    2003-01-01

    The assessment, cleanup, and remediation of hydrocarbon contaminated sites is covered in the Reference Method for Canada-Wide Standard for Petroleum Hydrocarbons-Tier 1 Method. It replaces several analytical methods used in the past by some laboratories and jurisdictions in Canada. The authors conducted two comparative evaluations to validate the Tier 1 Analytical Method. The first compared the Internal and External Standard Methods, and the second compared the Silica Gel Column Cleanup Method with the In-situ Silica Gel Cleanup Method. The Canadian Council of Ministers of the Environment (CCME) Tier 1 Method recommends and requires the External Standard Method to determine petroleum hydrocarbons (PHC) in soil samples. The Internal Method is widely used to quantify various organic and inorganic pollutants in environmental samples. The Tier 1 Method offers two options for the same extract cleanup. They are: Option A - In-situ Silica Gel Cleanup, and Option B - Silica Gel Column Cleanup. Linearity, precision, and PHC quantification results were the parameters considered for diesel and motor oil solutions, for diesel spiked soil samples, and for motor oil spiked soil samples. It was concluded that both the External and Internal Standard Methods for gas chromatograph (GC) determination of PHC in soil possess their own advantages. The PHC results obtained using the In-Situ Silica Gel Cleanup Method were lower than those obtained with the Silica Gel Column Cleanup Methods. The more efficient and effective sample cleanup method proved to be the Silica Gel Column Method. 13 refs., 7 tabs., 7 figs

  4. Standard Test Method for Determining the Linearity of a Photovoltaic Device Parameter with Respect To a Test Parameter

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2005-01-01

    1.1 This test method determines the degree of linearity of a photovoltaic device parameter with respect to a test parameter, for example, short-circuit current with respect to irradiance. 1.2 The linearity determined by this test method applies only at the time of testing, and implies no past or future performance level. 1.3 This test method applies only to non-concentrator terrestrial photovoltaic devices. 1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  5. Dissemination of the National Standard of Mass from INACAL using the gauss Markov method by generalized least squares

    OpenAIRE

    Taipe, Donny

    2017-01-01

    This article sustains the transfer of the national standard of mass (KP1) of INACAL to two reference standards ‘Weight 1’, ‘Weight 2’ and also KP2 (as witnessed mass standard and with known error). The dissemination was done using the Gauss Markov method by Generalized Least Squares. The uncertainty calculation was performed using Univariate Gaussian Distribution and Multivariate Gaussian Distribution; the latter was developed with the Monte Carlo method using a programming language called 'R...

  6. Standards in neurosonology. Part I

    Directory of Open Access Journals (Sweden)

    Joanna Wojcza

    2015-09-01

    Full Text Available The paper presents standards related to ultrasound imaging of the cerebral vasculature and structures. The aim of this paper is to standardize both the performance and description of ultrasound imaging of the extracranial and intracranial cerebral arteries as well as a study of a specifi c brain structure, i.e. substantia nigra hyperechogenicity. The following aspects are included in the description of standards for each ultrasonographic method: equipment requirements, patient preparation, study technique and documentation as well as the required elements of ultrasound description. Practical criteria for the diagnosis of certain pathologies in accordance with the latest literature were also presented. Furthermore, additional comments were included in some of the sections. Part I discusses standards for the performance, documentation and description of different ultrasound methods (Duplex, Doppler. Part II and III are devoted to standards for specifi c clinical situations (vasospasm, monitoring after the acute stage of stroke, detection of a right-toleft shunts, confi rmation of the arrest of the cerebral circulation, an assessment of the functional effi ciency of circle of Willis, an assessment of the cerebrovascular vasomotor reserve as well as the measurement of substantia nigra hyperechogenicity.

  7. Standards in neurosonology. Part III

    Directory of Open Access Journals (Sweden)

    Joanna Wojczal

    2016-06-01

    Full Text Available The paper presents standards related to ultrasound imaging of the cerebral vasculature and structures. The aim of this paper is to standardize both the performance and description of ultrasound imaging of the extracranial and intracranial cerebral arteries as well as a study of a specific brain structure, i.e. substantia nigra hyperechogenicity. The following aspects are included in the description of standards for each ultrasonographic method: equipment requirements, patient preparation, study technique and documentation as well as the required elements of ultrasound description. Practical criteria for the diagnosis of certain pathologies in accordance with the latest literature were also presented. Furthermore, additional comments were included in some of the sections. Part I discusses standards for the performance, documentation and description of different ultrasound methods (Duplex, Doppler. Part II and III are devoted to standards for specific clinical situations (vasospasm, monitoring after the acute stage of stroke, detection of a right-to-left shunts, confirmation of the arrest of the cerebral circulation, an assessment of the functional efficiency of circle of Willis, an assessment of the cerebrovascular vasomotor reserve as well as the measurement of substantia nigra hyperechogenicity.

  8. radioactive waste disposal standards abroad

    International Nuclear Information System (INIS)

    Lu Yan; Xin Pingping; Wu Jian; Zhang Xue

    2012-01-01

    With the world focus on human health and environmental protection, the problem of radioactive waste disposal has gradually become a global issue, and the focus of attention of public. The safety of radioactive waste disposal, is not only related to human health and environmental safety, but also an important factor of affecting the sustainable development of nuclear energy. In recent years the formulation of the radioactive waste disposal standards has been generally paid attention to at home and abroad, and it has made great progress. In China, radioactive waste management standards are being improved, and there are many new standards need to be developed. The revised task of implement standards is very arduous, and there are many areas for improvement about methods and procedures of the preparation of standards. This paper studies the current situation of radioactive waste disposal standards of the International Atomic Energy Agency, USA, France, Britain, Russia, Japan, and give some corresponding recommendations of our radioactive waste disposal standards. (authors)

  9. Comparison of x ray computed tomography number to proton relative linear stopping power conversion functions using a standard phantom.

    Science.gov (United States)

    Moyers, M F

    2014-06-01

    Adequate evaluation of the results from multi-institutional trials involving light ion beam treatments requires consideration of the planning margins applied to both targets and organs at risk. A major uncertainty that affects the size of these margins is the conversion of x ray computed tomography numbers (XCTNs) to relative linear stopping powers (RLSPs). Various facilities engaged in multi-institutional clinical trials involving proton beams have been applying significantly different margins in their patient planning. This study was performed to determine the variance in the conversion functions used at proton facilities in the U.S.A. wishing to participate in National Cancer Institute sponsored clinical trials. A simplified method of determining the conversion function was developed using a standard phantom containing only water and aluminum. The new method was based on the premise that all scanners have their XCTNs for air and water calibrated daily to constant values but that the XCTNs for high density/high atomic number materials are variable with different scanning conditions. The standard phantom was taken to 10 different proton facilities and scanned with the local protocols resulting in 14 derived conversion functions which were compared to the conversion functions used at the local facilities. For tissues within ±300 XCTN of water, all facility functions produced converted RLSP values within ±6% of the values produced by the standard function and within 8% of the values from any other facility's function. For XCTNs corresponding to lung tissue, converted RLSP values differed by as great as ±8% from the standard and up to 16% from the values of other facilities. For XCTNs corresponding to low-density immobilization foam, the maximum to minimum values differed by as much as 40%. The new method greatly simplifies determination of the conversion function, reduces ambiguity, and in the future could promote standardization between facilities. Although it

  10. A Case Study of Academic Writing Development Through Principled Versus Standard Clt Method at Binus University

    Directory of Open Access Journals (Sweden)

    Almodad Biduk Asmani

    2013-10-01

    Full Text Available The purpose of the research project is to investigate how far the academic writing skills of Binus University students can be developed through two conflicting CLT methods: standard and principled. The research project is expected to result in computer-animated format which can be used as one of the main tools in teaching and learning grammar at Binus University. The research project uses the qualitative approach, and thus uses verbal data. The research project involves two subject groups (experimental and control. The experimental group will receive the treatment of grammar learning by using the Principled CLT approach, while the control group receives the standard CLT approach. Survey is then conducted to the two groups so as to find out their comments on the two teaching methods. From the results of the questionnaires, it is found that Principled CLT method is favored for its knowledge and accuracy factors, while the Standard CLT is preferred for its fun and independence factors.   

  11. FY 2000 Immediate-effect type project for research and development for international standards supporting information technology industries. Standardization of the testing/evaluation methods for displays for information processing devices; 2000 nendo joho sangyo shien sokkogata kokusai hyojun kaihatsu jigyo seika hokokusho. Joho shori kikiyo display no shiken hyoka hoho no hyojunka

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-03-01

    Described herein are the FY 2000 results of the tests and studies for the methods of testing and evaluating the transparent electroconductive films necessary for production and product evaluation of liquid crystal displays, for their international standardization. The studies are directed to the testing/evaluation methods for internal stresses and adhesion force, surface shapes, and microstructures, and also to surveys on the market/technology trends, and preparation of the international standard drafts, among others. These result in, e.g., development of the quantitative evaluation technologies for internal stresses by the micro-sheet glass method, and surface shapes by atomic force microscopy. The local grain size and orientation are elucidated by transmission electron microscopy, to obtain new knowledge of the microstructures. Various technologies related to adhesion testing/evaluation methods are proposed for ISO/TC206, but it is found none is applicable to transparent electroconductive films. The standard drafts are prepared for standardization of the testing/evaluation methods for internal stresses, adhesion force and surface shapes. (NEDO)

  12. Inventory of Safety-related Codes and Standards for Energy Storage Systems with some Experiences related to Approval and Acceptance

    Energy Technology Data Exchange (ETDEWEB)

    Conover, David R.

    2014-09-11

    The purpose of this document is to identify laws, rules, model codes, codes, standards, regulations, specifications (CSR) related to safety that could apply to stationary energy storage systems (ESS) and experiences to date securing approval of ESS in relation to CSR. This information is intended to assist in securing approval of ESS under current CSR and to identification of new CRS or revisions to existing CRS and necessary supporting research and documentation that can foster the deployment of safe ESS.

  13. Binary trading relations and the limits of EDI standards

    DEFF Research Database (Denmark)

    Damsgaard, Jan; Truex, D.

    2000-01-01

    This paper provides a critical examination of electronic data interchange (EDI) standards and their application in different types of trading relationships. It argues that EDI standards are not directly comparable to more stable sets of technical standards in that they are dynamically tested...... and negotiated in use with each trading exchange. It takes the position that EDI standards are an emergent language form and must mean different things at the institutional and local levels. Using the lens of emergent linguistic analysis it shows how the institutional and local levels must always be distinct...... and yet can coexist. EDI standards can never represent the creation of an 'Esperanto of institutional communication'. Instead we believe that standards must be developed such that they support and accommodate general basic grammatical forms that can be customised to individual needs. The analysis...

  14. Dynamics of the standard model

    CERN Document Server

    Donoghue, John F; Holstein, Barry R

    2014-01-01

    Describing the fundamental theory of particle physics and its applications, this book provides a detailed account of the Standard Model, focusing on techniques that can produce information about real observed phenomena. The book begins with a pedagogic account of the Standard Model, introducing essential techniques such as effective field theory and path integral methods. It then focuses on the use of the Standard Model in the calculation of physical properties of particles. Rigorous methods are emphasized, but other useful models are also described. This second edition has been updated to include recent theoretical and experimental advances, such as the discovery of the Higgs boson. A new chapter is devoted to the theoretical and experimental understanding of neutrinos, and major advances in CP violation and electroweak physics have been given a modern treatment. This book is valuable to graduate students and researchers in particle physics, nuclear physics and related fields.

  15. Risk assessment for mineral oil : development of standardized analitical methods in soil and soil-like materials

    NARCIS (Netherlands)

    Harmsen, J.; Hutter, J.W.; Win, T.; Barnabas, I.; Whittle, P.; Hansen, N.; Sakai, H.

    2005-01-01

    The present standard methods for the determination of mineral oil in environmental matrices give a total concentration. This concentration is not found to be a good estimate for ecotoxicological, human and agricultural risks. It is shown that the existing ISO standards for mineral oil and volatile

  16. Regulations and standardization relative to the biomass combustion

    International Nuclear Information System (INIS)

    Autret, E.

    2009-01-01

    It does not exist regulations on pollutants emissions on domestic wood burning furnaces, however, these appliances are submitted to the European and french standardization concerning the safety rules, the use rules and the tests methods. Since 2007, these wood burning appliances on the market must have the European Community label. The green flame label was elaborated by the environment and energy control Agency (A.D.E.M.E.), and manufacturers of domestic appliances to promote the use of competitive wood burning appliances. concerning the collective and industrial heating, the installations of more 2 MW are framed by different categories of the installations classified for environment protection (I.C.P.E.) regulation according their fuel and power. The combustion installations of less than 2 MW are a particular case, they are framed by a sanitary department regulation and are controlled by the department directions of sanitary and social affairs. the limit values of emissions are summarized in tables. (N.C.)

  17. Standard Practice for Optical Distortion and Deviation of Transparent Parts Using the Double-Exposure Method

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This photographic practice determines the optical distortion and deviation of a line of sight through a simple transparent part, such as a commercial aircraft windshield or a cabin window. This practice applies to essentially flat or nearly flat parts and may not be suitable for highly curved materials. 1.2 Test Method F 801 addresses optical deviation (angluar deviation) and Test Method F 2156 addresses optical distortion using grid line slope. These test methods should be used instead of Practice F 733 whenever practical. 1.3 This standard does not purport to address the safety concerns associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  18. Standardization of fixation, processing and staining methods for the central nervous system of vertebrates.

    Science.gov (United States)

    Aldana Marcos, H J; Ferrari, C C; Benitez, I; Affanni, J M

    1996-12-01

    This paper reports the standardization of methods used for processing and embedding various vertebrate brains of different size in paraffin. Other technical details developed for avoiding frequent difficulties arising during laboratory routine are also reported. Some modifications of the Nissl and Klüver-Barrera staining methods are proposed. These modifications include: 1) a Nissl stain solution with a rapid and efficient action with easier differentiation; 2) the use of a cheap microwave oven for the Klüver-Barrera stain. These procedures have the advantage of permitting Nissl and Klüver-Barrera staining of nervous tissue in about five and fifteen minutes respectively. The proposed procedures have been tested in brains obtained from fish, amphibians, reptiles and mammals of different body sizes. They are the result of our long experience in preparing slides for comparative studies. Serial sections of excellent quality were regularly obtained in all the specimens studied. These standardized methods, being simple and quick, are recommended for routine use in neurobiological laboratories.

  19. H-Point Standard Addition Method for Simultaneous Determination of Eosin and Erytrosine

    Directory of Open Access Journals (Sweden)

    Amandeep Kaur

    2011-01-01

    Full Text Available A new, simple, sensitive and selective H-point standard addition method (HPSAM has been developed for resolving binary mixture of food colorants eosin and erythrosine, which show overlapped spectra. The method is based on the complexation of food dyes eosin and erythrosine with Fe(III complexing reagent at pH 5.5 and solubilizing complexes in triton x-100 micellar media. Absorbances at the two pairs of wavelengths, 540 and 550 nm (when eosin acts as analyte or 518 and 542 nm (when erythrosine act as analyte were monitored. This method has satisfactorily been applied for the determination of eosin and erythrosine dyes in synthetic mixtures and commercial products.

  20. Linear model correction: A method for transferring a near-infrared multivariate calibration model without standard samples

    Science.gov (United States)

    Liu, Yan; Cai, Wensheng; Shao, Xueguang

    2016-12-01

    Calibration transfer is essential for practical applications of near infrared (NIR) spectroscopy because the measurements of the spectra may be performed on different instruments and the difference between the instruments must be corrected. For most of calibration transfer methods, standard samples are necessary to construct the transfer model using the spectra of the samples measured on two instruments, named as master and slave instrument, respectively. In this work, a method named as linear model correction (LMC) is proposed for calibration transfer without standard samples. The method is based on the fact that, for the samples with similar physical and chemical properties, the spectra measured on different instruments are linearly correlated. The fact makes the coefficients of the linear models constructed by the spectra measured on different instruments are similar in profile. Therefore, by using the constrained optimization method, the coefficients of the master model can be transferred into that of the slave model with a few spectra measured on slave instrument. Two NIR datasets of corn and plant leaf samples measured with different instruments are used to test the performance of the method. The results show that, for both the datasets, the spectra can be correctly predicted using the transferred partial least squares (PLS) models. Because standard samples are not necessary in the method, it may be more useful in practical uses.

  1. FY 1999 project on the development of new industry support type international standards. Standardization of methods to test/evaluate plastic optical fiber; 1999 nendo shinki sangyo shiengata kokusai hyojun kaihatsu jigyo seika hokokusho. Plastic hikari fiber no shiken hyoka hoho no hyojunka

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-03-01

    The experimental research was conducted with the aim of developing test/evaluation methods of plastic optical fiber (POF) and proposing a draft on the standards to IEC, and the FY 1999 results were outlined. In the study of the band measuring method, the equipment designed was compared/verified in the pulse method with the frequency sweep method equipment for quartz base optical fiber use to confirm the accordance. Effects were further studied of experimental conditions including exciting conditions. Also about the frequency sweep method, the same verification was made to see the accordance with POF measured values in the pulse method. In the analysis by theoretical calculation, obtained were the results by which the experimental results can almost be explained. In the experiment on the optical transmission, the bit-error-rate was measured by transmitting digital signals to POF. As a result, it was confirmed that there were close relations between the band width of POF, bit-error-rate and changes in receiving sensitivity. As to the above-mentioned band experimental method, strategy for standardization was studied, and the making of a draft on the standards was started which is to be proposed at the meeting of TC86/SC86/WG1. (NEDO)

  2. Net Analyte Signal Standard Additions Method for Simultaneous Determination of Sulfamethoxazole and Trimethoprim in Pharmaceutical Formulations and Biological Fluids

    OpenAIRE

    Givianrad, M. H.; Mohagheghian, M.

    2012-01-01

    The applicability of a novel net analyte signal standard addition method (NASSAM) to the resolving of overlapping spectra corresponding to the sulfamethoxazole and trimethoprim was verified by UV-visible spectrophotometry. The results confirmed that the net analyte signal standard additions method with simultaneous addition of both analytes is suitable for the simultaneous determination of sulfamethoxazole and trimethoprim in aqueous media. Moreover, applying the net analyte signal standard a...

  3. Comparison of Standard Culture-Based Method to Culture-Independent Method for Evaluation of Hygiene Effects on the Hand Microbiome.

    Science.gov (United States)

    Zapka, C; Leff, J; Henley, J; Tittl, J; De Nardo, E; Butler, M; Griggs, R; Fierer, N; Edmonds-Wilson, S

    2017-03-28

    Hands play a critical role in the transmission of microbiota on one's own body, between individuals, and on environmental surfaces. Effectively measuring the composition of the hand microbiome is important to hand hygiene science, which has implications for human health. Hand hygiene products are evaluated using standard culture-based methods, but standard test methods for culture-independent microbiome characterization are lacking. We sampled the hands of 50 participants using swab-based and glove-based methods prior to and following four hand hygiene treatments (using a nonantimicrobial hand wash, alcohol-based hand sanitizer [ABHS], a 70% ethanol solution, or tap water). We compared results among culture plate counts, 16S rRNA gene sequencing of DNA extracted directly from hands, and sequencing of DNA extracted from culture plates. Glove-based sampling yielded higher numbers of unique operational taxonomic units (OTUs) but had less diversity in bacterial community composition than swab-based sampling. We detected treatment-induced changes in diversity only by using swab-based samples ( P hand hygiene industry methods and for future hand microbiome studies. On the basis of our results and previously published studies, we propose recommendations for best practices in hand microbiome research. IMPORTANCE The hand microbiome is a critical area of research for diverse fields, such as public health and forensics. The suitability of culture-independent methods for assessing effects of hygiene products on microbiota has not been demonstrated. This is the first controlled laboratory clinical hand study to have compared traditional hand hygiene test methods with newer culture-independent characterization methods typically used by skin microbiologists. This study resulted in recommendations for hand hygiene product testing, development of methods, and future hand skin microbiome research. It also demonstrated the importance of inclusion of skin physiological metadata in

  4. Standard Test Method for Measuring Fast-Neutron Reaction Rates by Radioactivation of Nickel

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 This test method covers procedures for measuring reaction rates by the activation reaction 58Ni(n,p)58Co. 1.2 This activation reaction is useful for measuring neutrons with energies above approximately 2.1 MeV and for irradiation times up to about 200 days in the absence of high thermal neutron fluence rates (for longer irradiations, see Practice E 261). 1.3 With suitable techniques fission-neutron fluence rates densities above 107 cm−2·s−1 can be determined. 1.4 Detailed procedures for other fast-neutron detectors are referenced in Practice E 261. 1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Note—The burnup corrections were com...

  5. A computer aided measurement method for unstable pelvic fractures based on standardized radiographs

    International Nuclear Information System (INIS)

    Zhao, Jing-xin; Zhao, Zhe; Zhang, Li-cheng; Su, Xiu-yun; Du, Hai-long; Zhang, Li-ning; Zhang, Li-hai; Tang, Pei-fu

    2015-01-01

    To set up a method for measuring radiographic displacement of unstable pelvic ring fractures based on standardized X-ray images and then test its reliability and validity using a software-based measurement technique. Twenty-five patients that were diagnosed as AO/OTA type B or C pelvic fractures with unilateral pelvis fractured and dislocated were eligible for inclusion by a review of medical records in our clinical centre. Based on the input pelvic preoperative CT data, the standardized X-ray images, including inlet, outlet, and anterior-posterior (AP) radiographs, were simulated using Armira software (Visage Imaging GmbH, Berlin, Germany). After representative anatomic landmarks were marked on the standardized X-ray images, the 2-dimensional (2D) coordinates of these points could be revealed in Digimizer software (Model: Mitutoyo Corp., Tokyo, Japan). Subsequently, we developed a formula that indicated the translational and rotational displacement patterns of the injured hemipelvis. Five separate observers calculated the displacement outcomes using the established formula and determined the rotational patterns using a 3D-CT model based on their overall impression. We performed 3D reconstruction of all the fractured pelvises using Mimics (Materialise, Haasrode, Belgium) and determined the translational and rotational displacement using 3-matic suite. The interobserver reliability of the new method was assessed by comparing the continuous measure and categorical outcomes using intraclass correlation coefficient (ICC) and kappa statistic, respectively. The interobserver reliability of the new method for translational and rotational measurement was high, with both ICCs above 0.9. Rotational outcome assessed by the new method was the same as that concluded by 3-matic software. The agreement for rotational outcome among orthopaedic surgeons based on overall impression was poor (kappa statistic, 0.250 to 0.426). Compared with the 3D reconstruction outcome, the

  6. Methods for Coding Tobacco-Related Twitter Data: A Systematic Review.

    Science.gov (United States)

    Lienemann, Brianna A; Unger, Jennifer B; Cruz, Tess Boley; Chu, Kar-Hai

    2017-03-31

    As Twitter has grown in popularity to 313 million monthly active users, researchers have increasingly been using it as a data source for tobacco-related research. The objective of this systematic review was to assess the methodological approaches of categorically coded tobacco Twitter data and make recommendations for future studies. Data sources included PsycINFO, Web of Science, PubMed, ABI/INFORM, Communication Source, and Tobacco Regulatory Science. Searches were limited to peer-reviewed journals and conference proceedings in English from January 2006 to July 2016. The initial search identified 274 articles using a Twitter keyword and a tobacco keyword. One coder reviewed all abstracts and identified 27 articles that met the following inclusion criteria: (1) original research, (2) focused on tobacco or a tobacco product, (3) analyzed Twitter data, and (4) coded Twitter data categorically. One coder extracted data collection and coding methods. E-cigarettes were the most common type of Twitter data analyzed, followed by specific tobacco campaigns. The most prevalent data sources were Gnip and Twitter's Streaming application programming interface (API). The primary methods of coding were hand-coding and machine learning. The studies predominantly coded for relevance, sentiment, theme, user or account, and location of user. Standards for data collection and coding should be developed to be able to more easily compare and replicate tobacco-related Twitter results. Additional recommendations include the following: sample Twitter's databases multiple times, make a distinction between message attitude and emotional tone for sentiment, code images and URLs, and analyze user profiles. Being relatively novel and widely used among adolescents and black and Hispanic individuals, Twitter could provide a rich source of tobacco surveillance data among vulnerable populations. ©Brianna A Lienemann, Jennifer B Unger, Tess Boley Cruz, Kar-Hai Chu. Originally published in the

  7. Standardized methods for Grand Canyon fisheries research 2015

    Science.gov (United States)

    Persons, William R.; Ward, David L.; Avery, Luke A.

    2013-01-01

    This document presents protocols and guidelines to persons sampling fishes in the Grand Canyon, to help ensure consistency in fish handling, fish tagging, and data collection among different projects and organizations. Most such research and monitoring projects are conducted under the general umbrella of the Glen Canyon Dam Adaptive Management Program and include studies by the U.S. Geological Survey (USGS), U.S. Fish and Wildlife Service (FWS), National Park Service (NPS), the Arizona Game and Fish Department (AGFD), various universities, and private contractors. This document is intended to provide guidance to fieldworkers regarding protocols that may vary from year to year depending on specific projects and objectives. We also provide herein documentation of standard methods used in the Grand Canyon that can be cited in scientific publications, as well as a summary of changes in protocols since the document was first created in 2002.

  8. A novel method for standardized application of fungal spore coatings for mosquito exposure bioassays.

    Science.gov (United States)

    Farenhorst, Marit; Knols, Bart G J

    2010-01-20

    Interest in the use of fungal entomopathogens against malaria vectors is growing. Fungal spores infect insects via the cuticle and can be applied directly on the insect to evaluate infectivity. For flying insects such as mosquitoes, however, application of fungal suspensions on resting surfaces is more realistic and representative of field settings. For this type of exposure, it is essential to apply specific amounts of fungal spores homogeneously over a surface for testing the effects of fungal dose and exposure time. Contemporary methods such as spraying or brushing spore suspensions onto substrates do not produce the uniformity and consistency that standardized laboratory assays require. Two novel fungus application methods using equipment developed in the paint industry are presented and compared. Wired, stainless steel K-bars were tested and optimized for coating fungal spore suspensions onto paper substrates. Different solvents and substrates were evaluated. Two types of coating techniques were compared, i.e. manual and automated coating. A standardized bioassay set-up was designed for testing coated spores against malaria mosquitoes. K-bar coating provided consistent applications of spore layers onto paper substrates. Viscous Ondina oil formulations were not suitable and significantly reduced spore infectivity. Evaporative Shellsol T solvent dried quickly and resulted in high spore infectivity to mosquitoes. Smooth proofing papers were the most effective substrate and showed higher infectivity than cardboard substrates. Manually and mechanically applied spore coatings showed similar and reproducible effects on mosquito survival. The standardized mosquito exposure bioassay was effective and consistent in measuring effects of fungal dose and exposure time. K-bar coating is a simple and consistent method for applying fungal spore suspensions onto paper substrates and can produce coating layers with accurate effective spore concentrations. The mosquito bioassay

  9. Standard test method for determination of breaking strength of ceramic tiles by three-point loading

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2001-01-01

    1.1 This test method covers the determination of breaking strength of ceramic tiles by three-point loading. 1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  10. Standard Test Method for Effects of Cleaning and Chemical Maintenance Materials on Painted Aircraft Surfaces

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 This test method covers determination of the effects of cleaning solutions and liquid cleaner concentrates on painted aircraft surfaces (Note 1). Streaking, discoloration, and blistering may be determined visually. Softening is determined with a series of specially prepared pencils wherein determination of the softest pencil to rupture the paint film is made. Note 1—This test method is applicable to any paint film that is exposed to cleaning materials. MIL-PRF-85285 has been selected as a basic example. When other paint finishes are used, refer to the applicable material specification for panel preparation and system curing prior to testing. 1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user ...

  11. Standardization of the method for measurement of plasma estrone by radioimmunoassay

    International Nuclear Information System (INIS)

    Vilanova, M.S.V.; Moreira, A.C.; Sala, M.M. de; Sa, M.F.S. de

    1994-01-01

    The present paper has as objective standardize a radioimmunoassay method for measurement of plasma estrone. Ethyl ether was used for plasma extraction. The sensitivity (Minimal detectable dose) was 3,7 pg/tube; the reproducibility (inter assay error) was 8,6%; the precision (intra assay error) was 4,1%. As a biological control the plasma estrone was ml) and in 24 patients with polycystic ovarian syndrome (median = 77,9 pg/ml). (author). 6 refs, 2 figs, 2 tabs

  12. Relative quantification of mRNA: comparison of methods currently used for real-time PCR data analysis

    Directory of Open Access Journals (Sweden)

    Koppel Juraj

    2007-12-01

    Full Text Available Abstract Background Fluorescent data obtained from real-time PCR must be processed by some method of data analysis to obtain the relative quantity of target mRNA. The method chosen for data analysis can strongly influence results of the quantification. Results To compare the performance of six techniques which are currently used for analysing fluorescent data in real-time PCR relative quantification, we quantified four cytokine transcripts (IL-1β, IL-6 TNF-α, and GM-CSF in an in vivo model of colonic inflammation. Accuracy of the methods was tested by quantification on samples with known relative amounts of target mRNAs. Reproducibility of the methods was estimated by the determination of the intra-assay and inter-assay variability. Cytokine expression normalized to the expression of three reference genes (ACTB, HPRT, SDHA was then determined using the six methods for data analysis. The best results were obtained with the relative standard curve method, comparative Ct method and with DART-PCR, LinRegPCR and Liu & Saint exponential methods when average amplification efficiency was used. The use of individual amplification efficiencies in DART-PCR, LinRegPCR and Liu & Saint exponential methods significantly impaired the results. The sigmoid curve-fitting (SCF method produced medium performance; the results indicate that the use of appropriate type of fluorescence data and in some instances manual selection of the number of amplification cycles included in the analysis is necessary when the SCF method is applied. We also compared amplification efficiencies (E and found that although the E values determined by different methods of analysis were not identical, all the methods were capable to identify two genes whose E values significantly differed from other genes. Conclusion Our results show that all the tested methods can provide quantitative values reflecting the amounts of measured mRNA in samples, but they differ in their accuracy and

  13. A new method to detect event-related potentials based on Pearson's correlation.

    Science.gov (United States)

    Giroldini, William; Pederzoli, Luciano; Bilucaglia, Marco; Melloni, Simone; Tressoldi, Patrizio

    2016-12-01

    Event-related potentials (ERPs) are widely used in brain-computer interface applications and in neuroscience.  Normal EEG activity is rich in background noise, and therefore, in order to detect ERPs, it is usually necessary to take the average from multiple trials to reduce the effects of this noise.  The noise produced by EEG activity itself is not correlated with the ERP waveform and so, by calculating the average, the noise is decreased by a factor inversely proportional to the square root of N , where N is the number of averaged epochs. This is the easiest strategy currently used to detect ERPs, which is based on calculating the average of all ERP's waveform, these waveforms being time- and phase-locked.  In this paper, a new method called GW6 is proposed, which calculates the ERP using a mathematical method based only on Pearson's correlation. The result is a graph with the same time resolution as the classical ERP and which shows only positive peaks representing the increase-in consonance with the stimuli-in EEG signal correlation over all channels.  This new method is also useful for selectively identifying and highlighting some hidden components of the ERP response that are not phase-locked, and that are usually hidden in the standard and simple method based on the averaging of all the epochs.  These hidden components seem to be caused by variations (between each successive stimulus) of the ERP's inherent phase latency period (jitter), although the same stimulus across all EEG channels produces a reasonably constant phase. For this reason, this new method could be very helpful to investigate these hidden components of the ERP response and to develop applications for scientific and medical purposes. Moreover, this new method is more resistant to EEG artifacts than the standard calculations of the average and could be very useful in research and neurology.  The method we are proposing can be directly used in the form of a process written in the well

  14. Standardization of 32P activity determination method in soil-root cores for root distribution studies

    International Nuclear Information System (INIS)

    Sharma, R.B.; Ghildyal, B.P.

    1976-01-01

    The root distribution of wheat variety UP 301 was obtained by determining the 32 P activity in soil-root cores by two methods, viz., ignition and triacid digestion. Root distribution obtained by these two methods was compared with that by standard root core washing procedure. The percent error in root distribution as determined by triacid digestion method was within +- 2.1 to +- 9.0 as against +- 5.5 to +- 21.2 by ignition method. Thus triacid digestion method proved better over the ignition method. (author)

  15. A no-gold-standard technique for objective assessment of quantitative nuclear-medicine imaging methods.

    Science.gov (United States)

    Jha, Abhinav K; Caffo, Brian; Frey, Eric C

    2016-04-07

    The objective optimization and evaluation of nuclear-medicine quantitative imaging methods using patient data is highly desirable but often hindered by the lack of a gold standard. Previously, a regression-without-truth (RWT) approach has been proposed for evaluating quantitative imaging methods in the absence of a gold standard, but this approach implicitly assumes that bounds on the distribution of true values are known. Several quantitative imaging methods in nuclear-medicine imaging measure parameters where these bounds are not known, such as the activity concentration in an organ or the volume of a tumor. We extended upon the RWT approach to develop a no-gold-standard (NGS) technique for objectively evaluating such quantitative nuclear-medicine imaging methods with patient data in the absence of any ground truth. Using the parameters estimated with the NGS technique, a figure of merit, the noise-to-slope ratio (NSR), can be computed, which can rank the methods on the basis of precision. An issue with NGS evaluation techniques is the requirement of a large number of patient studies. To reduce this requirement, the proposed method explored the use of multiple quantitative measurements from the same patient, such as the activity concentration values from different organs in the same patient. The proposed technique was evaluated using rigorous numerical experiments and using data from realistic simulation studies. The numerical experiments demonstrated that the NSR was estimated accurately using the proposed NGS technique when the bounds on the distribution of true values were not precisely known, thus serving as a very reliable metric for ranking the methods on the basis of precision. In the realistic simulation study, the NGS technique was used to rank reconstruction methods for quantitative single-photon emission computed tomography (SPECT) based on their performance on the task of estimating the mean activity concentration within a known volume of interest

  16. A no-gold-standard technique for objective assessment of quantitative nuclear-medicine imaging methods

    International Nuclear Information System (INIS)

    Jha, Abhinav K; Frey, Eric C; Caffo, Brian

    2016-01-01

    The objective optimization and evaluation of nuclear-medicine quantitative imaging methods using patient data is highly desirable but often hindered by the lack of a gold standard. Previously, a regression-without-truth (RWT) approach has been proposed for evaluating quantitative imaging methods in the absence of a gold standard, but this approach implicitly assumes that bounds on the distribution of true values are known. Several quantitative imaging methods in nuclear-medicine imaging measure parameters where these bounds are not known, such as the activity concentration in an organ or the volume of a tumor. We extended upon the RWT approach to develop a no-gold-standard (NGS) technique for objectively evaluating such quantitative nuclear-medicine imaging methods with patient data in the absence of any ground truth. Using the parameters estimated with the NGS technique, a figure of merit, the noise-to-slope ratio (NSR), can be computed, which can rank the methods on the basis of precision. An issue with NGS evaluation techniques is the requirement of a large number of patient studies. To reduce this requirement, the proposed method explored the use of multiple quantitative measurements from the same patient, such as the activity concentration values from different organs in the same patient. The proposed technique was evaluated using rigorous numerical experiments and using data from realistic simulation studies. The numerical experiments demonstrated that the NSR was estimated accurately using the proposed NGS technique when the bounds on the distribution of true values were not precisely known, thus serving as a very reliable metric for ranking the methods on the basis of precision. In the realistic simulation study, the NGS technique was used to rank reconstruction methods for quantitative single-photon emission computed tomography (SPECT) based on their performance on the task of estimating the mean activity concentration within a known volume of interest

  17. RAMESES publication standards: meta-narrative reviews

    Directory of Open Access Journals (Sweden)

    Wong Geoff

    2013-01-01

    overall response rate of 90%. Conclusion This project used multiple sources to draw together evidence and expertise in meta-narrative reviews. For each item we have included an explanation for why it is important and guidance on how it might be reported. Meta-narrative review is a relatively new method for evidence synthesis and as experience and methodological developments occur, we anticipate that these standards will evolve to reflect further theoretical and methodological developments. We hope that these standards will act as a resource that will contribute to improving the reporting of meta-narrative reviews. To encourage dissemination of the RAMESES publication standards, this article is co-published in the Journal of Advanced Nursing and is freely accessible on Wiley Online Library (http://www.wileyonlinelibrary.com/journal/jan. Please see related articles http://www.biomedcentral.com/1741-7015/11/21 and http://www.biomedcentral.com/1741-7015/11/22

  18. Abnormal brain activation and connectivity to standardized disorder-related visual scenes in social anxiety disorder.

    Science.gov (United States)

    Heitmann, Carina Yvonne; Feldker, Katharina; Neumeister, Paula; Zepp, Britta Maria; Peterburs, Jutta; Zwitserlood, Pienie; Straube, Thomas

    2016-04-01

    Our understanding of altered emotional processing in social anxiety disorder (SAD) is hampered by a heterogeneity of findings, which is probably due to the vastly different methods and materials used so far. This is why the present functional magnetic resonance imaging (fMRI) study investigated immediate disorder-related threat processing in 30 SAD patients and 30 healthy controls (HC) with a novel, standardized set of highly ecologically valid, disorder-related complex visual scenes. SAD patients rated disorder-related as compared with neutral scenes as more unpleasant, arousing and anxiety-inducing than HC. On the neural level, disorder-related as compared with neutral scenes evoked differential responses in SAD patients in a widespread emotion processing network including (para-)limbic structures (e.g. amygdala, insula, thalamus, globus pallidus) and cortical regions (e.g. dorsomedial prefrontal cortex (dmPFC), posterior cingulate cortex (PCC), and precuneus). Functional connectivity analysis yielded an altered interplay between PCC/precuneus and paralimbic (insula) as well as cortical regions (dmPFC, precuneus) in SAD patients, which emphasizes a central role for PCC/precuneus in disorder-related scene processing. Hyperconnectivity of globus pallidus with amygdala, anterior cingulate cortex (ACC) and medial prefrontal cortex (mPFC) additionally underlines the relevance of this region in socially anxious threat processing. Our findings stress the importance of specific disorder-related stimuli for the investigation of altered emotion processing in SAD. Disorder-related threat processing in SAD reveals anomalies at multiple stages of emotion processing which may be linked to increased anxiety and to dysfunctionally elevated levels of self-referential processing reported in previous studies. © 2016 Wiley Periodicals, Inc.

  19. Condition Assessment Survey (CAS) Program. Deficiency standards and inspections methods manual: Volume 1, 0.01 Foundations and footings

    Energy Technology Data Exchange (ETDEWEB)

    1993-05-01

    General information is presented for asset determinant factor/CAS repair codes/CAS cost factors; guide sheet tool & material listing; testing methods; inspection frequency; standard system design life tables; system work breakdown structure; and general system/material data. Deficiency standards and inspection methods are given for footings - spread/strip/grade beams; foundation walls; foundation dampproofing/waterproofing; excavation/backfill/ and piles & caissons.

  20. A critical analysis of one standard and five methods to monitor surface wetness and time-of-wetness

    Science.gov (United States)

    Camuffo, Dario; della Valle, Antonio; Becherini, Francesca

    2018-05-01

    Surface wetness is a synergistic factor to determine atmospheric corrosion, monument weathering, mould growth, sick buildings, etc. However, its detection and monitoring are neither easy nor homogeneous, for a number of factors that may affect readings. Various types of methods and sensors, either commercial or prototypes built in the lab, have been investigated and compared, i.e. the international standard ISO 9223 to evaluate corrosivity after wetness and time-of-wetness; indirect evaluation of wetness, based on the dew point calculated after the output of temperature and relative humidity sensors and direct measurements by means of capacitive wetness sensors, safety sensors, rain sensors (also known as leaf wetness sensors), infrared reflection sensors and fibre optic sensors. A comparison between the different methods is presented, specifying physical principles, forms of wetting to which they are respondent (i.e. condensation, ice melting, splashing drops, percolation and capillary rise), critical factors, use and cost.

  1. Standard Test Method for Testing Polymeric Seal Materials for Geothermal and/or High Temperature Service Under Sealing Stress

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1985-01-01

    1.1 This test method covers the initial evaluation of (screening) polymeric materials for seals under static sealing stress and at elevated temperatures. 1.2 This test method applies to geothermal service only if used in conjunction with Test Method E 1068. 1.3 The test fluid is distilled water. 1.4 The values stated in SI units are to be regarded as the standard. The values in parentheses are for information only. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  2. Comparison of Boolean analysis and standard phylogenetic methods using artificially evolved and natural mt-tRNA sequences from great apes.

    Science.gov (United States)

    Ari, Eszter; Ittzés, Péter; Podani, János; Thi, Quynh Chi Le; Jakó, Eena

    2012-04-01

    Boolean analysis (or BOOL-AN; Jakó et al., 2009. BOOL-AN: A method for comparative sequence analysis and phylogenetic reconstruction. Mol. Phylogenet. Evol. 52, 887-97.), a recently developed method for sequence comparison uses the Iterative Canonical Form of Boolean functions. It considers sequence information in a way entirely different from standard phylogenetic methods (i.e. Maximum Parsimony, Maximum-Likelihood, Neighbor-Joining, and Bayesian analysis). The performance and reliability of Boolean analysis were tested and compared with the standard phylogenetic methods, using artificially evolved - simulated - nucleotide sequences and the 22 mitochondrial tRNA genes of the great apes. At the outset, we assumed that the phylogeny of Hominidae is generally well established, and the guide tree of artificial sequence evolution can also be used as a benchmark. These offer a possibility to compare and test the performance of different phylogenetic methods. Trees were reconstructed by each method from 2500 simulated sequences and 22 mitochondrial tRNA sequences. We also introduced a special re-sampling method for Boolean analysis on permuted sequence sites, the P-BOOL-AN procedure. Considering the reliability values (branch support values of consensus trees and Robinson-Foulds distances) we used for simulated sequence trees produced by different phylogenetic methods, BOOL-AN appeared as the most reliable method. Although the mitochondrial tRNA sequences of great apes are relatively short (59-75 bases long) and the ratio of their constant characters is about 75%, BOOL-AN, P-BOOL-AN and the Bayesian approach produced the same tree-topology as the established phylogeny, while the outcomes of Maximum Parsimony, Maximum-Likelihood and Neighbor-Joining methods were equivocal. We conclude that Boolean analysis is a promising alternative to existing methods of sequence comparison for phylogenetic reconstruction and congruence analysis. Copyright © 2012 Elsevier Inc. All

  3. New internal standard method for activation analysis and its application. Determination of Co, Ni, Rb, Sr in pepperbush by means of photon activation

    Energy Technology Data Exchange (ETDEWEB)

    Yagi, M.; Masumoto, K. (Tohoku Univ., Sendai (Japan). Lab. of Nuclear Science)

    1984-08-01

    A new internal standard method for activation analysis has been developed. In this method a suitable element present originally in the sample is used as an internal standard and the comparative standard is prepared by applying the standard addition method to the duplicated sample. The present method has the great advantages that the comparative standard spiked with the element of interest has the same matrix as the sample, and then the amount of the element to be determined in the sample can be evaluated easily by using a very simple equation even though the sample and comparative standard are irradiated separately by particles with different flux. Neither correction of the inhomogeneities of flux between the sample and comparative standard, nor that of the self-shielding effects are necessary for the present method. The usefulness of the method was examined through the determination of Co, Ni, Rb and Sr in pepperbush by means of photon activation, and the precision and accuracy of the method were proved to be valid. 29 refs.

  4. Comparison of Standard Culture-Based Method to Culture-Independent Method for Evaluation of Hygiene Effects on the Hand Microbiome

    Directory of Open Access Journals (Sweden)

    C. Zapka

    2017-03-01

    Full Text Available Hands play a critical role in the transmission of microbiota on one’s own body, between individuals, and on environmental surfaces. Effectively measuring the composition of the hand microbiome is important to hand hygiene science, which has implications for human health. Hand hygiene products are evaluated using standard culture-based methods, but standard test methods for culture-independent microbiome characterization are lacking. We sampled the hands of 50 participants using swab-based and glove-based methods prior to and following four hand hygiene treatments (using a nonantimicrobial hand wash, alcohol-based hand sanitizer [ABHS], a 70% ethanol solution, or tap water. We compared results among culture plate counts, 16S rRNA gene sequencing of DNA extracted directly from hands, and sequencing of DNA extracted from culture plates. Glove-based sampling yielded higher numbers of unique operational taxonomic units (OTUs but had less diversity in bacterial community composition than swab-based sampling. We detected treatment-induced changes in diversity only by using swab-based samples (P < 0.001; we were unable to detect changes with glove-based samples. Bacterial cell counts significantly decreased with use of the ABHS (P < 0.05 and ethanol control (P < 0.05. Skin hydration at baseline correlated with bacterial abundances, bacterial community composition, pH, and redness across subjects. The importance of the method choice was substantial. These findings are important to ensure improvement of hand hygiene industry methods and for future hand microbiome studies. On the basis of our results and previously published studies, we propose recommendations for best practices in hand microbiome research.

  5. Newly developed standard reference materials for organic contaminant analysis

    Energy Technology Data Exchange (ETDEWEB)

    Poster, D.; Kucklick, J.; Schantz, M.; Porter, B.; Wise, S. [National Inst. of Stand. and Technol., Gaithersburg, MD (USA). Center for Anal. Chem.

    2004-09-15

    The National Institute of Standards and Technology (NIST) has issued a number of Standard Reference Materials (SRM) for specified analytes. The SRMs are biota and biological related materials, sediments and particle related SRMs. The certified compounds for analysis are polychlorinated biphenyls (PCB), polycylic aromatic hydrocarbons (PAH) and their nitro-analogues, chlorinated pesticides, methylmercury, organic tin compounds, fatty acids, polybrominated biphenyl ethers (PBDE). The authors report on origin of materials and analytic methods. (uke)

  6. Transfer standard for the spectral density of relative intensity noise of optical fiber sources near 1550 nm

    International Nuclear Information System (INIS)

    Obarski, Gregory E.; Splett, Jolene D.

    2001-01-01

    We have developed a transfer standard for the spectral density of relative intensity noise (RIN) of optical fiber sources near 1550 nm. Amplified spontaneous emission (ASE) from an erbium-doped fiber amplifier (EDFA), when it is optically filtered over a narrow band (<5 nm), yields a stable RIN spectrum that is practically constant to several tens of gigahertz. The RIN is calculated from the power spectral density as measured with a calibrated optical spectrum analyzer. For a typical device it is -110 dB/Hz, with uncertainty ≤0.12 dB/Hz. The invariance of the RIN under attenuation yields a considerable dynamic range with respect to rf noise levels. Results are compared with those from a second method that uses a distributed-feedback laser (DFB) that has a Poisson-limited RIN. Application of each method to the same RIN measurement system yields frequency-dependent calibration functions that, when they are averaged, differ by ≤0.2 dB. [copyright] 2001 Optical Society of America

  7. Development of liquid chromatographic methods for the determination of phytosterols in Standard Reference Materials containing saw palmetto.

    Science.gov (United States)

    Bedner, Mary; Schantz, Michele M; Sander, Lane C; Sharpless, Katherine E

    2008-05-23

    Liquid chromatographic (LC) methods using atmospheric pressure chemical ionization/mass spectrometric (APCI-MS) detection were developed for the separation and analysis of the phytosterols campesterol, cycloartenol, lupenone, lupeol, beta-sitosterol, and stigmasterol. Brassicasterol and cholesterol were also included for investigation as internal standards. The methods were used to identify and quantify the phytosterols in each of two Serenoa repens (saw palmetto) Standard Reference Materials (SRMs) developed by the National Institute of Standards and Technology (NIST). Values obtained by LC-MS were compared to those obtained using the more traditional approach of gas chromatography with flame ionization detection. This is the first reported use of LC-MS to determine phytosterols in saw palmetto dietary supplement materials.

  8. Implementation of a standardized out-of-hospital management method for Parkinson dysphagia

    Directory of Open Access Journals (Sweden)

    Hongying Wei

    Full Text Available Summary Objective: Our objective is to explore the effectiveness and feasibility of establishing a swallowing management clinic to implement out-of-hospital management for Parkinson disease (PD patients with dysphagia. Method: Two-hundred seventeen (217 voluntary PD patients with dysphagia in a PD outpatient clinic were divided into a control group with 100 people, and an experimental group with 117 people. The control group was given dysphagia rehabilitation guidance. The experimental group was presented with the standardized out-of-hospital management method as overall management and information and education materials. Rehabilitation efficiency and incidence rate of dysphagia, as well as relevant complications of both groups were compared after a 6-month intervention. Results: Rehabilitation efficiency and the incidence rate of dysphagia including relevant complications of patients treated with the standardized out-of-hospital management were compared with those seen in the control group. The differences have distinct statistics meaning (p<0.01. Conclusion: Establishing a swallowing management protocol for outpatient setting can effectively help the recovery of the function of swallowing, reduce the incidence rate of dysphagia complications and improve the quality of life in patients with PD.

  9. A validated specific stability-indicating RP-HPLC assay method for Ambrisentan and its related substances.

    Science.gov (United States)

    Narayana, M B V; Chandrasekhar, K B; Rao, B M

    2014-09-01

    A validated specific stability-indicating reverse-phase liquid chromatographic method was developed for the quantitative determination of Ambrisentan as well as its related substances in bulk samples, pharmaceutical dosage forms in the presence of degradation products and its related impurities. Forced degradation studies were performed on bulk samples of Ambrisentan as per the ICH-prescribed stress conditions using acid, base, oxidative, thermal stress and photolytic degradation to show the stability-indicating power of the LC method. Significant degradation in acidic, basic stress conditions was observed and no degradation was observed in other stress conditions. The chromatographic method was optimized using the samples generated from the forced degradation studies and the impurity-spiked solution. Good resolution between the peaks corresponds to Ambrisentan-related impurities and degradation products from the analyte were achieved on a SunFire C18 column using a mobile phase consisting of a mixture of potassium dihydrogen orthophosphate at a pH adjusted to 2.5 with ortho-phosphoric acid in water and a mixture of acetonitrile:methanol using a simple linear gradient. The detection was carried out at 225 nm. The limit of detection and the limit of quantification for the Ambrisentan and its related impurities were established. The stressed test solutions were assayed against the qualified working standard of Ambrisentan and the mass balance in each case was between 98.9 and 100.3%, indicating that the developed LC method was stability indicating. Validation of the developed LC method was carried out as per the ICH requirements. The developed method was found to be suitable to check the quality of bulk samples of Ambrisentan at the time of batch release and also during its storage (long-term and accelerated stability). © The Author [2013]. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  10. Standard test method for quantitative determination of americium 241 in plutonium by Gamma-Ray spectrometry

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1994-01-01

    1.1 This test method covers the quantitative determination of americium 241 by gamma-ray spectrometry in plutonium nitrate solution samples that do not contain significant amounts of radioactive fission products or other high specific activity gamma-ray emitters. 1.2 This test method can be used to determine the americium 241 in samples of plutonium metal, oxide and other solid forms, when the solid is appropriately sampled and dissolved. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  11. Preparation and LSC standardization of ''89 Sr (DNP) using the CIEMAT/NIST method

    International Nuclear Information System (INIS)

    Rodriguez Barquero, L.; Arcos Merino, J.M. Los; Grau Malonda, A.

    1994-01-01

    A procedure for preparation of liquid scintillation counting samples of the strontium DNP complex, labelled with ''89 Sr, is described. The chemical quench, the counting stability and spectral evolution of this compound is studied in six scintillators, Toluene, Toluene-alcohol, Dioxane-naphthalene, HiSafe II, Ultima-Gold and Instagel. The liquid scintillation standardization of ''89Sr-DNP by the CIEMAT/NIST method, using Hisafe II and Ultima-Gold scintillators, has been carried out. The discrepancies between experimental and computed efficiencies are lower than 0.38% and 0.48%, respectively. The solution has been standardized in terms of activity concentration to an overall uncertainty of 0.38%. (Author)

  12. Preparation and LSC Standardization of ''89Sr (DNP) Using the CIEMAT/NIST Method

    International Nuclear Information System (INIS)

    Rodriguez Barquero, L.; Los Arcos Merino, J. M.; Grau Malonda, A.

    1994-01-01

    A procedure for preparation of liquid scintillation counting samples of the strontium DNP complex, labelled with ''89Sr, is described, the chemical quench, the counting stability and spectral evolution of this compound is studied in six scintillators, Toluene, Toluene-alcohol, Dioxane-naphthalene, HiSafe II, Ultima- Gold and Instagel. The liquid scintillation standardization of 89Sr-DNP by the CIEMAT/NIST method, using HiSafe II and Ultima-Gold scintillators, has been carried out. The discrepancies between experimental and computed efficiencies are lower than 0.38% and 0.48%, respectively. The solution has been standardized in terms of activity concentration to an overall uncertainty of 0,38%. (Author) 10 refs

  13. Building America Guidance for Identifying and Overcoming Code, Standard, and Rating Method Barriers

    Energy Technology Data Exchange (ETDEWEB)

    Cole, P. C. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Halverson, M. A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2013-09-01

    This guidance document was prepared using the input from the meeting summarized in the draft CSI Roadmap to provide Building America research teams and partners with specific information and approaches to identifying and overcoming potential barriers to Building America innovations arising in and/or stemming from codes, standards, and rating methods.

  14. Analysis of zirconium and nickel based alloys and zirconium oxides by relative and internal monostandard neutron activation analysis methods

    International Nuclear Information System (INIS)

    Shinde, Amol D.; Acharya, Raghunath; Reddy, Annareddy V. R.

    2017-01-01

    The chemical characterization of metallic alloys and oxides is conventionally carried out by wet chemical analytical methods and/or instrumental methods. Instrumental neutron activation analysis (INAA) is capable of analyzing samples nondestructively. As a part of a chemical quality control exercise, Zircaloys 2 and 4, nimonic alloy, and zirconium oxide samples were analyzed by two INAA methods. The samples of alloys and oxides were also analyzed by inductively coupled plasma optical emission spectroscopy (ICP-OES) and direct current Arc OES methods, respectively, for quality assurance purposes. The samples are important in various fields including nuclear technology. Samples were neutron irradiated using nuclear reactors, and the radioactive assay was carried out using high-resolution gamma-ray spectrometry. Major to trace mass fractions were determined using both relative and internal monostandard (IM) NAA methods as well as OES methods. In the case of alloys, compositional analyses as well as concentrations of some trace elements were determined, whereas in the case of zirconium oxides, six trace elements were determined. For method validation, British Chemical Standard (BCS)-certified reference material 310/1 (a nimonic alloy) was analyzed using both relative INAA and IM-NAA methods. The results showed that IM-NAA and relative INAA methods can be used for nondestructive chemical quality control of alloys and oxide samples

  15. Analysis of zirconium and nickel based alloys and zirconium oxides by relative and internal monostandard neutron activation analysis methods

    Energy Technology Data Exchange (ETDEWEB)

    Shinde, Amol D.; Acharya, Raghunath; Reddy, Annareddy V. R. [Bhabha Atomic Research Centre, Mumbai (India)

    2017-04-15

    The chemical characterization of metallic alloys and oxides is conventionally carried out by wet chemical analytical methods and/or instrumental methods. Instrumental neutron activation analysis (INAA) is capable of analyzing samples nondestructively. As a part of a chemical quality control exercise, Zircaloys 2 and 4, nimonic alloy, and zirconium oxide samples were analyzed by two INAA methods. The samples of alloys and oxides were also analyzed by inductively coupled plasma optical emission spectroscopy (ICP-OES) and direct current Arc OES methods, respectively, for quality assurance purposes. The samples are important in various fields including nuclear technology. Samples were neutron irradiated using nuclear reactors, and the radioactive assay was carried out using high-resolution gamma-ray spectrometry. Major to trace mass fractions were determined using both relative and internal monostandard (IM) NAA methods as well as OES methods. In the case of alloys, compositional analyses as well as concentrations of some trace elements were determined, whereas in the case of zirconium oxides, six trace elements were determined. For method validation, British Chemical Standard (BCS)-certified reference material 310/1 (a nimonic alloy) was analyzed using both relative INAA and IM-NAA methods. The results showed that IM-NAA and relative INAA methods can be used for nondestructive chemical quality control of alloys and oxide samples.

  16. Establishing Upper Limits for Item Ratings for the Angoff Method: Are Resulting Standards More 'Realistic'?

    Science.gov (United States)

    Reid, Jerry B.

    This report investigates an area of uncertainty in using the Angoff method for setting standards, namely whether or not a judge's conceptualizations of borderline group performance are realistic. Ratings are usually made with reference to the performance of this hypothetical group, therefore the Angoff method's success is dependent on this point.…

  17. Standard Test Method for Testing Nonmetallic Seal Materials by Immersion in a Simulated Geothermal Test Fluid

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1985-01-01

    1.1 This test method covers a procedure for a laboratory test for performing an initial evaluation (screening) of nonmetallic seal materials by immersion in a simulated geothermal test fluid. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific precautionary statements, see Section 6 and 11.7.

  18. Searching for beyond the Standard Model physics using direct and indirect methods at LHCb

    CERN Document Server

    Hall, Samuel C P; Golutvin, Andrey

    It is known that the Standard Model of particle physics is incomplete in its description of nature at a fundamental level. For example, the Standard Model can neither incorporate dark matter nor explain the matter dominated nature of the Universe. This thesis presents three analyses undertaken using data collected by the LHCb detector. Each analysis searches for indications of physics beyond the Standard Model in dierent decays of B mesons, using dierent techniques. Notably, two analyses look for indications of new physics using indirect methods, and one uses a direct approach. The rst analysis shows evidence for the rare decay $B^{+} \\rightarrow D^{+}_{s}\\phi$ with greater than 3 $\\sigma$ signicance; this also constitutes the rst evidence for a fullyhadronic annihilation-type decay of a $B^{+}$ meson. A measurement of the branching fraction of the decay $B^{+} \\rightarrow D^{+}_{s}\\phi$ is seen to be higher than, but still compatible with, Standard Model predictions. The CP-asymmetry of the decay is also ...

  19. Microbleed detection using automated segmentation (MIDAS): a new method applicable to standard clinical MR images.

    Science.gov (United States)

    Seghier, Mohamed L; Kolanko, Magdalena A; Leff, Alexander P; Jäger, Hans R; Gregoire, Simone M; Werring, David J

    2011-03-23

    Cerebral microbleeds, visible on gradient-recalled echo (GRE) T2* MRI, have generated increasing interest as an imaging marker of small vessel diseases, with relevance for intracerebral bleeding risk or brain dysfunction. Manual rating methods have limited reliability and are time-consuming. We developed a new method for microbleed detection using automated segmentation (MIDAS) and compared it with a validated visual rating system. In thirty consecutive stroke service patients, standard GRE T2* images were acquired and manually rated for microbleeds by a trained observer. After spatially normalizing each patient's GRE T2* images into a standard stereotaxic space, the automated microbleed detection algorithm (MIDAS) identified cerebral microbleeds by explicitly incorporating an "extra" tissue class for abnormal voxels within a unified segmentation-normalization model. The agreement between manual and automated methods was assessed using the intraclass correlation coefficient (ICC) and Kappa statistic. We found that MIDAS had generally moderate to good agreement with the manual reference method for the presence of lobar microbleeds (Kappa = 0.43, improved to 0.65 after manual exclusion of obvious artefacts). Agreement for the number of microbleeds was very good for lobar regions: (ICC = 0.71, improved to ICC = 0.87). MIDAS successfully detected all patients with multiple (≥2) lobar microbleeds. MIDAS can identify microbleeds on standard MR datasets, and with an additional rapid editing step shows good agreement with a validated visual rating system. MIDAS may be useful in screening for multiple lobar microbleeds.

  20. Standardization of HPTLC method for the estimation of oxytocin in edibles.

    Science.gov (United States)

    Rani, Roopa; Medhe, Sharad; Raj, Kumar Rohit; Srivastava, Manmohan

    2013-12-01

    Adulteration in food stuff has been regarded as a major social evil and is a mind-boggling problem in society. In this study, a rapid, reliable and cost effective High Performance thin layer Chromatography (HPTLC) has been established for the estimation of oxytocin (adulterant) in vegetables, fruits and milk samples. Oxytocin is one of the most frequently used adulterant added in vegetables and fruits for increasing the growth rate and also to enhance milk production from lactating animals. The standardization of the method was based on simulation parameters of mobile phase, stationary phase and saturation time. The mobile phase used was MeOH: Ammonia (pH 6.8), optimized stationary phase was silica gel and saturation time of 5 min. The method was validated by testing its linearity, accuracy, precision, repeatability and limits of detection and quantification. Thus, the proposed method is simple, rapid and specific and was successfully employed for quality and quantity monitoring of oxytocin content in edible products.

  1. CoRE: A context-aware relation extraction method for relation completion

    KAUST Repository

    Li, Zhixu; Sharaf, Mohamed Abdel Fattah; Sitbon, Laurianne; Du, Xiaoyong; Zhou, Xiaofang

    2014-01-01

    We identify relation completion (RC) as one recurring problem that is central to the success of novel big data applications such as Entity Reconstruction and Data Enrichment. Given a semantic relation {\\cal R}, RC attempts at linking entity pairs between two entity lists under the relation {\\cal R}. To accomplish the RC goals, we propose to formulate search queries for each query entity \\alpha based on some auxiliary information, so that to detect its target entity \\beta from the set of retrieved documents. For instance, a pattern-based method (PaRE) uses extracted patterns as the auxiliary information in formulating search queries. However, high-quality patterns may decrease the probability of finding suitable target entities. As an alternative, we propose CoRE method that uses context terms learned surrounding the expression of a relation as the auxiliary information in formulating queries. The experimental results based on several real-world web data collections demonstrate that CoRE reaches a much higher accuracy than PaRE for the purpose of RC. © 1989-2012 IEEE.

  2. CoRE: A context-aware relation extraction method for relation completion

    KAUST Repository

    Li, Zhixu

    2014-04-01

    We identify relation completion (RC) as one recurring problem that is central to the success of novel big data applications such as Entity Reconstruction and Data Enrichment. Given a semantic relation {\\\\cal R}, RC attempts at linking entity pairs between two entity lists under the relation {\\\\cal R}. To accomplish the RC goals, we propose to formulate search queries for each query entity \\\\alpha based on some auxiliary information, so that to detect its target entity \\\\beta from the set of retrieved documents. For instance, a pattern-based method (PaRE) uses extracted patterns as the auxiliary information in formulating search queries. However, high-quality patterns may decrease the probability of finding suitable target entities. As an alternative, we propose CoRE method that uses context terms learned surrounding the expression of a relation as the auxiliary information in formulating queries. The experimental results based on several real-world web data collections demonstrate that CoRE reaches a much higher accuracy than PaRE for the purpose of RC. © 1989-2012 IEEE.

  3. Current Methods Applied to Biomaterials - Characterization Approaches, Safety Assessment and Biological International Standards.

    Science.gov (United States)

    Oliveira, Justine P R; Ortiz, H Ivan Melendez; Bucio, Emilio; Alves, Patricia Terra; Lima, Mayara Ingrid Sousa; Goulart, Luiz Ricardo; Mathor, Monica B; Varca, Gustavo H C; Lugao, Ademar B

    2018-04-10

    Safety and biocompatibility assessment of biomaterials are themes of constant concern as advanced materials enter the market as well as products manufactured by new techniques emerge. Within this context, this review provides an up-to-date approach on current methods for the characterization and safety assessment of biomaterials and biomedical devices from a physicalchemical to a biological perspective, including a description of the alternative methods in accordance with current and established international standards. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  4. Examining database persistence of ISO/EN 13606 standardized electronic health record extracts: relational vs. NoSQL approaches.

    Science.gov (United States)

    Sánchez-de-Madariaga, Ricardo; Muñoz, Adolfo; Lozano-Rubí, Raimundo; Serrano-Balazote, Pablo; Castro, Antonio L; Moreno, Oscar; Pascual, Mario

    2017-08-18

    The objective of this research is to compare the relational and non-relational (NoSQL) database systems approaches in order to store, recover, query and persist standardized medical information in the form of ISO/EN 13606 normalized Electronic Health Record XML extracts, both in isolation and concurrently. NoSQL database systems have recently attracted much attention, but few studies in the literature address their direct comparison with relational databases when applied to build the persistence layer of a standardized medical information system. One relational and two NoSQL databases (one document-based and one native XML database) of three different sizes have been created in order to evaluate and compare the response times (algorithmic complexity) of six different complexity growing queries, which have been performed on them. Similar appropriate results available in the literature have also been considered. Relational and non-relational NoSQL database systems show almost linear algorithmic complexity query execution. However, they show very different linear slopes, the former being much steeper than the two latter. Document-based NoSQL databases perform better in concurrency than in isolation, and also better than relational databases in concurrency. Non-relational NoSQL databases seem to be more appropriate than standard relational SQL databases when database size is extremely high (secondary use, research applications). Document-based NoSQL databases perform in general better than native XML NoSQL databases. EHR extracts visualization and edition are also document-based tasks more appropriate to NoSQL database systems. However, the appropriate database solution much depends on each particular situation and specific problem.

  5. STANDARDIZATION AND VALIDATION OF METHODS FOR ENUMERATION OF FECAL COLIFORM AND SALMONELLA IN BIOSOLIDS

    Science.gov (United States)

    Current federal regulations require monitoring for fecal coliforms or Salmonella in biosolids destined for land application. Methods used for analysis of fecal coliforms and Salmonella were reviewed and a standard protocol was developed. The protocols were then evaluated by testi...

  6. Standard test method for conducting drop-weight test to determine nil-ductility transition temperature of ferritic steels

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2006-01-01

    1.1 This test method covers the determination of the nil-ductility transition (NDT) temperature of ferritic steels, 5/8 in. (15.9 mm) and thicker. 1.2 This test method may be used whenever the inquiry, contract, order, or specification states that the steels are subject to fracture toughness requirements as determined by the drop-weight test. 1.3 The values stated in inch-pound units are to be regarded as the standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  7. Standard test method for determination of low concentrations of uranium in oils and organic liquids by X-ray fluorescence

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2011-01-01

    1.1 This test method covers the steps necessary for the preparation and analysis by X-ray fluorescence (XRF) of oils and organic solutions containing uranium. Two different preparation techniques are described. 1.2 The procedure is valid for those solutions containing 20 to 2000 μg uranium per mL as presented to the spectrometer for the solution technique and 200 to 50 000 μg uranium per g for the pellet technique. 1.3 This test method requires the use of an appropriate internal standard. Care must be taken to ascertain that samples analyzed by this test method do not contain the internal standard or that this contamination, whenever present, has been corrected for mathematically. Such corrections are not addressed in this procedure. Care must be taken that the internal standard and sample medium are compatible; that is, samples must be miscible with tri-n-butyl phosphate (TBP) and must not remove the internal standard from solution. Alternatively, a scatter line may be used as the internal standard. 1....

  8. ISO standardization in nuclear technology

    Energy Technology Data Exchange (ETDEWEB)

    Brabec, D [Ustav pro Vyzkum, Vyrobu a Vyuziti Radioisotopu, Prague (Czechoslovakia); Cermak, O [Urad pro Normalizaci a Mereni, Prague (Czechoslovakia)

    1984-10-01

    The activity is described of the technical commission ISO/TC 85 which is currently divided into 4 subcommissions (SC) and 24 working groups. SC 1 ''Terminology, definitions, units, abbreviations'' has one working group. The most important document of this SC is ISO 921-1972 (Dictionary of nuclear technology). SC 2 ''Radiation protection'' has 9 working groups and has processed standards in dosimetry. SC 3 ''Technology of power reactors'' has 6 working groups and its work is related to IAEA activities within the NUSS program. SC 4 ''Technology of nuclear fuels'' has 8 working groups. SC 4 has compiled the basic standards for sealed sources and methods of testing their tightness. The results of the work of this group have been reflected into the standardization work of CMEA. A list is given of published international standards within TC 85.

  9. Development of the H-point standard additions method for coupled liquid-chromatography and UV-visible spectrophotometry

    Energy Technology Data Exchange (ETDEWEB)

    Campins-Falco, Pilar; Bosch-Reig, Francisco; Herraez-Hernandez, Rosa; Sevillano-Cabeza, Adela (Universidad de Valencia (Spain). Facultad de Quimica, Departamento de Quimica Analitica)

    1992-02-10

    This work establishes the fundamentals of the H-point standard additions method for liquid chromatography for the simultaneous analysis of binary mixtures with overlapped chromatographic peaks. The method was compared with the deconvolution method of peak suppression and the second derivative of elution profiles. Different mixtures of diuretics were satisfactorily resolved. (author). 21 refs.; 9 figs.; 2 tabs.

  10. Method of simulating spherical voids for use as a radiographic standard

    International Nuclear Information System (INIS)

    Foster, B.E.

    1977-01-01

    A method of simulating small spherical voids in metal is provided. The method entails drilling or etching a hemispherical depression of the desired diameter in each of two sections of metal, the sections being flat plates or different diameter cylinders. A carbon bead is placed in one of the hemispherical voids and is used as a guide to align the second hemispherical void with that in the other plate. The plates are then bonded together with epoxy, tape or similar material and the two aligned hemispheres form a sphere within the material; thus a void of a known size has been created. This type of void can be used to simulate a pore in the development of radiographic techniques of actual voids (porosity) in welds and serve as a radiographic standard

  11. Standard Test Method for Measurement of Hydrogen Embrittlement Threshold in Steel by the Incremental Step Loading Technique

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This test method establishes a procedure to measure the susceptibility of steel to a time-delayed failure such as that caused by hydrogen. It does so by measuring the threshold for the onset of subcritical crack growth using standard fracture mechanics specimens, irregular-shaped specimens such as notched round bars, or actual product such as fasteners (2) (threaded or unthreaded) springs or components as identified in SAE J78, J81, and J1237. 1.2 This test method is used to evaluate quantitatively: 1.2.1 The relative susceptibility of steels of different composition or a steel with different heat treatments; 1.2.2 The effect of residual hydrogen in the steel as a result of processing, such as melting, thermal mechanical working, surface treatments, coatings, and electroplating; 1.2.3 The effect of hydrogen introduced into the steel caused by external environmental sources of hydrogen, such as fluids and cleaners maintenance chemicals, petrochemical products, and galvanic coupling in an aqueous enviro...

  12. From Classical to Discrete Gravity through Exponential Non-Standard Lagrangians in General Relativity

    Directory of Open Access Journals (Sweden)

    Rami Ahmad El-Nabulsi

    2015-08-01

    Full Text Available Recently, non-standard Lagrangians have gained a growing importance in theoretical physics and in the theory of non-linear differential equations. However, their formulations and implications in general relativity are still in their infancies despite some advances in contemporary cosmology. The main aim of this paper is to fill the gap. Though non-standard Lagrangians may be defined by a multitude form, in this paper, we considered the exponential type. One basic feature of exponential non-standard Lagrangians concerns the modified Euler-Lagrange equation obtained from the standard variational analysis. Accordingly, when applied to spacetime geometries, one unsurprisingly expects modified geodesic equations. However, when taking into account the time-like paths parameterization constraint, remarkably, it was observed that mutually discrete gravity and discrete spacetime emerge in the theory. Two different independent cases were obtained: A geometrical manifold with new spacetime coordinates augmented by a metric signature change and a geometrical manifold characterized by a discretized spacetime metric. Both cases give raise to Einstein’s field equations yet the gravity is discretized and originated from “spacetime discreteness”. A number of mathematical and physical implications of these results were discussed though this paper and perspectives are given accordingly.

  13. Comparison between Amnisure Placental Alpha Microglobulin-1 Rapid Immunoassay and Standard Diagnostic Methods for Detection of Rupture of Membranes

    Directory of Open Access Journals (Sweden)

    Beng Kwang Ng

    2013-01-01

    Full Text Available Objective. To determine the diagnostic accuracy of placental alpha microglobulin-1 assay and standard diagnostic methods for detecting rupture of membrane. Study Design. Prospective diagnostic study, between June 2011 to November 2011 at a tertiary centre. Initial evaluation included both the standard diagnostic methods for rupture of membranes and placental alpha microglobulin-1 immunoassay. The actual rupture of membranes was diagnosed on review of the medical records after delivery (absence of membrane or a positive pad chart. Main Outcome Measures. Placental alpha microglobulin-1 immunoassay and standard diagnostic methods for diagnosis of rupture of membrane. Results. A total of 211 patients were recruited. At initial presentation, 187 patients (88.6% had ruptured membranes, while 24 patients (11.4% had intact membranes. Placental alpha microglobulin-1 immunoassay confirmed rupture of membranes at initial presentation with a sensitivity of 95.7% (179 of 187, specificity of 100% (24 of 24, positive predictive value of 100% (179 of 179, and negative predictive value of 75.0% (24 of 32. By comparison, the conventional standard diagnostic methods had a sensitivity of 78.1% (146 of 187, specificity of 100% (24 of 24, positive predictive value of 100% (146 of 146, and negative predictive value of 36.9% (24 of 65 in diagnosing rupture of membrane. Conclusion. Placental alpha-microglobulin-1 immunoassay is a rapid and accurate method for confirming the diagnosis of rupture of membrane. It was superior to conventional standard diagnostic methods (pooling, nitrazine, and ferning, the nitrazine test alone or fern test alone.

  14. Non-standard perturbative methods for the effective potential in λφ4 QFT

    International Nuclear Information System (INIS)

    Okopinska, A.

    1986-07-01

    The effective potential in scalar QFT is calculated in the non-standard perturbative methods and compared with the conventional loop expansion. In the space time dimensions 0 and 1 the results are compared with the ''exact'' effective potential obtained numerically. In 4 dimensions we show that λφ 4 theory is non-interacting. (author)

  15. Project in fiscal 2000 of developing international standards for supporting new industries. Standardization of method for evaluating performance of textile material for interlocking concrete block pavement; 2000 nendo shinki sangyo shiengata kokusai hyojun kaihatsu jigyo seika hokokusho. Block hosoyo sen'i zairyo no seino hyoka hoho no hyojunka

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-03-01

    Targeting at realization of international standardization of a textile material (geotextile) used for interlocking concrete block pavement, R and D has been performed on a performance evaluation method consistent with field works. This paper summarizes the achievements in fiscal 2000. A literature survey has revealed that manuals prepared by the U.S. AASHTO, and ISO related standards show the test method for single geotextile, and guidelines on durability, but the method for evaluating the durability assuming the actual using conditions has not been standardized. The result of a field test reveals definite effects of existence of geotextile on the usability of block pavement in the water permeable bitumen stabilized roadbed, wherein the effectiveness of the geotextile was verified. In the research of an indoor evaluation test method, it was identified that the test method using a roller compactor and a wheel tracking testing machine can reproduce the behavior of block pavement at site, and it is a method that can identify the durability of the geotextile to some extent. (NEDO)

  16. Mobile Robot and Mobile Manipulator Research Towards ASTM Standards Development.

    Science.gov (United States)

    Bostelman, Roger; Hong, Tsai; Legowik, Steven

    2016-01-01

    Performance standards for industrial mobile robots and mobile manipulators (robot arms onboard mobile robots) have only recently begun development. Low cost and standardized measurement techniques are needed to characterize system performance, compare different systems, and to determine if recalibration is required. This paper discusses work at the National Institute of Standards and Technology (NIST) and within the ASTM Committee F45 on Driverless Automatic Guided Industrial Vehicles. This includes standards for both terminology, F45.91, and for navigation performance test methods, F45.02. The paper defines terms that are being considered. Additionally, the paper describes navigation test methods that are near ballot and docking test methods being designed for consideration within F45.02. This includes the use of low cost artifacts that can provide alternatives to using relatively expensive measurement systems.

  17. The relation between respiratory motion artifact correction and lung standardized uptake value

    International Nuclear Information System (INIS)

    Yin Lijie; Liu Xiaojian; Liu Jie; Xu Rui; Yan Jue

    2014-01-01

    PET/CT is playing an important role in disease diagnosis and therapeutic evaluation. But the respiratory motion artifact may bring trouble in diagnosis and therapy. There are many methods to correct the respiratory motion artifact. Respiratory gated PET/CT is applied most extensively of them. Using respiratory gated PET/CT to correct respiratory motion artifact can increase the maximum standardized uptake value of lung lesion obviously, thereby improving the quality of image and accuracy of diagnosis. (authors)

  18. Temperature standards, what and where: resources for effective temperature measurements

    International Nuclear Information System (INIS)

    Johnston, W.W. Jr.

    1982-01-01

    Many standards have been published to describe devices, methods, and other topics. How they are developed and by whom are briefly described, and an attempt is made to extract most of those relating to temperature measurements. A directory of temperature standards and their sources is provided

  19. Standard test method for determining whether gas-leak-detector fluid solutions can cause stress corrosion cracking of brass alloys

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2005-01-01

    1.1 This test method covers an accelerated test method for evaluating the tendency of gas leak detection fluids (LDFs) to cause stress corrosion cracking (SCC) of brass components in compressed gas service. 1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and to determine the applicability of regulatory limitations prior to use.

  20. Laboratory Evaluation of Air Flow Measurement Methods for Residential HVAC Returns for New Instrument Standards

    Energy Technology Data Exchange (ETDEWEB)

    Walker, Iain [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Stratton, Chris [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2015-08-01

    This project improved the accuracy of air flow measurements used in commissioning California heating and air conditioning systems in Title 24 (Building and Appliance Efficiency Standards), thereby improving system performance and efficiency of California residences. The research team at Lawrence Berkeley National Laboratory addressed the issue that typical tools used by contractors in the field to test air flows may not be accurate enough to measure return flows used in Title 24 applications. The team developed guidance on performance of current diagnostics as well as a draft test method for use in future evaluations. The study team prepared a draft test method through ASTM International to determine the uncertainty of air flow measurements at residential heating ventilation and air conditioning returns and other terminals. This test method, when finalized, can be used by the Energy Commission and other entities to specify required accuracy of measurement devices used to show compliance with standards.

  1. Validation of a reversed-phase high-performance liquid chromatographic method for the determination of free amino acids in rice using l-theanine as the internal standard.

    Science.gov (United States)

    Liyanaarachchi, G V V; Mahanama, K R R; Somasiri, H P P S; Punyasiri, P A N

    2018-02-01

    The study presents the validation results of the method carried out for analysis of free amino acids (FAAs) in rice using l-theanine as the internal standard (IS) with o-phthalaldehyde (OPA) reagent using high-performance liquid chromatography-fluorescence detection. The detection and quantification limits of the method were in the range 2-16μmol/kg and 3-19μmol/kg respectively. The method had a wide working range from 25 to 600μmol/kg for each individual amino acid, and good linearity with regression coefficients greater than 0.999. Precision measured in terms of repeatability and reproducibility, expressed as percentage relative standard deviation (% RSD) was below 9% for all the amino acids analyzed. The recoveries obtained after fortification at three concentration levels were in the range 75-105%. In comparison to l-norvaline, findings revealed that l-theanine is suitable as an IS and the validated method can be used for FAA determination in rice. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. [COMPUTER TECHNOLOGY FOR ACCOUNTING OF CONFOUNDERS IN THE RISK ASSESSMENT IN COMPARATIVE STUDIES ON THE BASE OF THE METHOD OF STANDARDIZATION].

    Science.gov (United States)

    Shalaumova, Yu V; Varaksin, A N; Panov, V G

    2016-01-01

    There was performed an analysis of the accounting of the impact of concomitant variables (confounders), introducing a systematic error in the assessment of the impact of risk factors on the resulting variable. The analysis showed that standardization is an effective method for the reduction of the shift of risk assessment. In the work there is suggested an algorithm implementing the method of standardization based on stratification, providing for the minimization of the difference of distributions of confounders in groups on risk factors. To automate the standardization procedures there was developed a software available on the website of the Institute of Industrial Ecology, UB RAS. With the help of the developed software by numerically modeling there were determined conditions of the applicability of the method of standardization on the basis of stratification for the case of the normal distribution on the response and confounder and linear relationship between them. Comparison ofresults obtained with the help of the standardization with statistical methods (logistic regression and analysis of covariance) in solving the problem of human ecology, has shown that obtaining close results is possible if there will be met exactly conditions for the applicability of statistical methods. Standardization is less sensitive to violations of conditions of applicability.

  3. Work related perceived stress and muscle activity during standardized computer work among female computer users

    DEFF Research Database (Denmark)

    Larsman, P; Thorn, S; Søgaard, K

    2009-01-01

    The current study investigated the associations between work-related perceived stress and surface electromyographic (sEMG) parameters (muscle activity and muscle rest) during standardized simulated computer work (typing, editing, precision, and Stroop tasks). It was part of the European case......-control study, NEW (Neuromuscular assessment in the Elderly Worker). The present cross-sectional study was based on a questionnaire survey and sEMG measurements among Danish and Swedish female computer users aged 45 or older (n=49). The results show associations between work-related perceived stress...... and trapezius muscle activity and rest during standardized simulated computer work, and provide partial empirical support for the hypothesized pathway of stress induced muscle activity in the association between an adverse psychosocial work environment and musculoskeletal symptoms in the neck and shoulder....

  4. Standard test method for determining the crevice repassivation potential of corrosion-resistant alloys using a potentiodynamic-galvanostatic-potentiostatic technique

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 This test method covers a procedure for conducting anodic polarization studies to determine the crevice repassivation potential for corrosion–resistant alloys. The concept of the repassivation potential is similar to that of the protection potential given in Reference Test Method G 5. 1.2 The test method consists in applying successively potentiodynamic, galvanostatic, and potentiostatic treatments for the initial formation and afterward repassivation of crevice corrosion. 1.3 This test method is a complement to Test Method G 61. 1.4 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  5. — study of the use of two standard- and non-standard-measuring devices

    Directory of Open Access Journals (Sweden)

    Paweł Ostapkowicz

    2014-03-01

    Full Text Available This paper deals with leak detection in liquid transmission pipelines. Diagnostic method based on negative pressure wave detection is taken into account here. The paper focuses on variant of this method, related to the use of only two measurement points (devices, placed at the inlet and outlet of the pipeline. Standard transducers for measurement of pressure signals and non-standard elaborated technique for measurement of new diagnostic signals were used. New diagnostic signals, conventionally named the signals of weak interactions, result from the work of special devices (correctors joined to the pipeline. In order to compare both hardware solutions key performance attributes for the analyzed leak detection method were determined. The bases of such assessment were experimental tests. They were conducted with the use of a physical model of a pipeline. The pipeline was 380 meters long, 34 mm in internal diameter and made of polyethylene (PEHD pipes. The medium pumped through the pipeline was water. Carrying out such research, diagnostic procedures elaborated by the author were used and tested.[b]Keywords[/b]: technical diagnostics, pipelines, leak detection

  6. Standard test methods for performance characteristics of metallic bonded resistance strain gages

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1992-01-01

    1.1 The purpose of this standard is to provide uniform test methods for the determination of strain gauge performance characteristics. Suggested testing equipment designs are included. 1.2 Test Methods E 251 describes methods and procedures for determining five strain gauge parameters: Section Part I—General Requirements 7 Part II—Resistance at a Reference Temperature 8 Part III—Gauge Factor at a Reference Temperature 9 Part IV—Temperature Coefficient of Gauge Factor\t10 Part V—Transverse Sensitivity\t11 Part VI—Thermal Output\t12 1.3 Strain gauges are very sensitive devices with essentially infinite resolution. Their response to strain, however, is low and great care must be exercised in their use. The performance characteristics identified by these test methods must be known to an acceptable accuracy to obtain meaningful results in field applications. 1.3.1 Strain gauge resistance is used to balance instrumentation circuits and to provide a reference value for measurements since all data are...

  7. The History of Infant Formula: Quality, Safety, and Standard Methods.

    Science.gov (United States)

    Wargo, Wayne F

    2016-01-01

    Food-related laws and regulations have existed since ancient times. Egyptian scrolls prescribed the labeling needed for certain foods. In ancient Athens, beer and wines were inspected for purity and soundness, and the Romans had a well-organized state food control system to protect consumers from fraud or bad produce. In Europe during the Middle Ages, individual countries passed laws concerning the quality and safety of eggs, sausages, cheese, beer, wine, and bread; some of these laws still exist today. But more modern dietary guidelines and food regulations have their origins in the latter half of the 19th century when the first general food laws were adopted and basic food control systems were implemented to monitor compliance. Around this time, science and food chemistry began to provide the tools to determine "purity" of food based primarily on chemical composition and to determine whether it had been adulterated in any way. Since the key chemical components of mammalian milk were first understood, infant formulas have steadily advanced in complexity as manufacturers attempt to close the compositional gap with human breast milk. To verify these compositional innovations and ensure product quality and safety, infant formula has become one of the most regulated foods in the world. The present paper examines the historical development of nutritional alternatives to breastfeeding, focusing on efforts undertaken to ensure the quality and safety from antiquity to present day. The impact of commercial infant formulas on global regulations is addressed, along with the resulting need for harmonized, fit-for-purpose, voluntary consensus standard methods.

  8. A comparative uncertainty study of the calibration of macrolide antibiotic reference standards using quantitative nuclear magnetic resonance and mass balance methods

    International Nuclear Information System (INIS)

    Liu Shuyu; Hu Changqin

    2007-01-01

    This study introduces the general method of quantitative nuclear magnetic resonance (qNMR) for the calibration of reference standards of macrolide antibiotics. Several qNMR experimental conditions were optimized including delay, which is an important parameter of quantification. Three kinds of macrolide antibiotics were used to validate the accuracy of the qNMR method by comparison with the results obtained by the high performance liquid chromatography (HPLC) method. The purities of five common reference standards of macrolide antibiotics were measured by the 1 H qNMR method and the mass balance method, respectively. The analysis results of the two methods were compared. The qNMR is quick and simple to use. In a new medicine research and development process, qNMR provides a new and reliable method for purity analysis of the reference standard

  9. A typology of health marketing research methods--combining public relations methods with organizational concern.

    Science.gov (United States)

    Rotarius, Timothy; Wan, Thomas T H; Liberman, Aaron

    2007-01-01

    Research plays a critical role throughout virtually every conduit of the health services industry. The key terms of research, public relations, and organizational interests are discussed. Combining public relations as a strategic methodology with the organizational concern as a factor, a typology of four different research methods emerges. These four health marketing research methods are: investigative, strategic, informative, and verification. The implications of these distinct and contrasting research methods are examined.

  10. Standard test method for measuring pH of soil for use in corrosion testing

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1995-01-01

    1.1 This test method covers a procedure for determining the pH of a soil in corrosion testing. The principle use of the test is to supplement soil resistivity measurements and thereby identify conditions under which the corrosion of metals in soil may be accentuated (see G 57 - 78 (1984)). 1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  11. Absolute standardization of radionuclides with complex decay by the peak-sum coincidence method and photon spectrometry with HPGe detector

    International Nuclear Information System (INIS)

    Silva, Ronaldo Lins da

    2017-01-01

    This study aims to present a new methodology for absolute standardization of 133 Ba, which is a complex decay radionuclide, using the peak-sum coincidence method associated with gamma spectrometry with a high resolution germanium detector. The use of the method of direct multiplication of matrices allowed identifying all the energies of sum coincidence, as well as their probabilities of detection, which made possible the calculation of the probabilities of detecting the energies of interferences. In addition, with the use of deconvolution software it was possible to obtain the areas of energy without interference of other sums, and by means of the deduced equation for the peak sum method, it was possible to standardize 133 Ba. The result of the activity was compared with those found by the absolute methods existing in the LNMRI, where the result obtained by coincidence peak-sum was highlighted among all. The estimated uncertainties were below 0.30%, compatible with the results found in the literature by other absolute methods. Thus, it was verified that the methodology was able to standardize radionuclide 133 Ba with precision, accuracy, easiness and quickness. The relevance of this doctoral thesis is to provide the National Metrology Laboratory of Ionizing Radiation (LNMRI) with a new absolute standardization methodology for complex decay radionuclides. (author)

  12. Efficient exact-exchange time-dependent density-functional theory methods and their relation to time-dependent Hartree-Fock.

    Science.gov (United States)

    Hesselmann, Andreas; Görling, Andreas

    2011-01-21

    A recently introduced time-dependent exact-exchange (TDEXX) method, i.e., a response method based on time-dependent density-functional theory that treats the frequency-dependent exchange kernel exactly, is reformulated. In the reformulated version of the TDEXX method electronic excitation energies can be calculated by solving a linear generalized eigenvalue problem while in the original version of the TDEXX method a laborious frequency iteration is required in the calculation of each excitation energy. The lowest eigenvalues of the new TDEXX eigenvalue equation corresponding to the lowest excitation energies can be efficiently obtained by, e.g., a version of the Davidson algorithm appropriate for generalized eigenvalue problems. Alternatively, with the help of a series expansion of the new TDEXX eigenvalue equation, standard eigensolvers for large regular eigenvalue problems, e.g., the standard Davidson algorithm, can be used to efficiently calculate the lowest excitation energies. With the help of the series expansion as well, the relation between the TDEXX method and time-dependent Hartree-Fock is analyzed. Several ways to take into account correlation in addition to the exact treatment of exchange in the TDEXX method are discussed, e.g., a scaling of the Kohn-Sham eigenvalues, the inclusion of (semi)local approximate correlation potentials, or hybrids of the exact-exchange kernel with kernels within the adiabatic local density approximation. The lowest lying excitations of the molecules ethylene, acetaldehyde, and pyridine are considered as examples.

  13. ENAA of iodine in standard reference material lyophilized human urine

    International Nuclear Information System (INIS)

    Zhang Yongbao; Wang Ke; Wang Ganfeng

    1997-01-01

    The contents of iodine in two kinds of standard reference materials lyophilized human urine are determined by ENAA. The sensitivity of this method is ten times higher than that of TNAA, and the relative standard deviations of ten measurements are 2.9% and 3.3%, respectively. Two certificated reference samples are used for verification of the analysis. The analytical results are in agreement with the recommended values, and the relative error is less than 3%

  14. 76 FR 16728 - Announcement of the American Petroleum Institute's Standards Activities

    Science.gov (United States)

    2011-03-25

    ... (Specific Gravity), or API Gravity of Crude Petroleum and Liquid Petroleum Products by Hydrometer Method... by Pressure Hydrometer, 3rd Ed. MPMS Chapter 9.3, Standard Test Method for Density, Relative Density...

  15. Comparison of a New Cobinamide-Based Method to a Standard Laboratory Method for Measuring Cyanide in Human Blood

    Science.gov (United States)

    Swezey, Robert; Shinn, Walter; Green, Carol; Drover, David R.; Hammer, Gregory B.; Schulman, Scott R.; Zajicek, Anne; Jett, David A.; Boss, Gerry R.

    2013-01-01

    Most hospital laboratories do not measure blood cyanide concentrations, and samples must be sent to reference laboratories. A simple method is needed for measuring cyanide in hospitals. The authors previously developed a method to quantify cyanide based on the high binding affinity of the vitamin B12 analog, cobinamide, for cyanide and a major spectral change observed for cyanide-bound cobinamide. This method is now validated in human blood, and the findings include a mean inter-assay accuracy of 99.1%, precision of 8.75% and a lower limit of quantification of 3.27 µM cyanide. The method was applied to blood samples from children treated with sodium nitroprusside and it yielded measurable results in 88 of 172 samples (51%), whereas the reference laboratory yielded results in only 19 samples (11%). In all 19 samples, the cobinamide-based method also yielded measurable results. The two methods showed reasonable agreement when analyzed by linear regression, but not when analyzed by a standard error of the estimate or paired t-test. Differences in results between the two methods may be because samples were assayed at different times on different sample types. The cobinamide-based method is applicable to human blood, and can be used in hospital laboratories and emergency rooms. PMID:23653045

  16. Standardization of methods of maxillofacial roentgenology

    International Nuclear Information System (INIS)

    Rabukhina, N.A.; Arzhantsev, A.P.; Chikirdin, Eh.G.; Tombak, M.I.; Stavitskij, R.V.; Vasil'ev, Yu.D.

    1989-01-01

    Typical errors in teeth roentgenography reproduced in experiment, indicate that considerable disproportional distortions of images of anatomical structures which are decisive for radiodiagnosis, may occur in these cases. Standardization of intraoral roentgenography is based on a strict position of the patient's head, angle of inclination and alignment of a tube. Specialized R3-1 film should be used

  17. Net Analyte Signal Standard Additions Method for Simultaneous Determination of Sulfamethoxazole and Trimethoprim in Pharmaceutical Formulations and Biological Fluids

    Directory of Open Access Journals (Sweden)

    M. H. Givianrad

    2012-01-01

    Full Text Available The applicability of a novel net analyte signal standard addition method (NASSAM to the resolving of overlapping spectra corresponding to the sulfamethoxazole and trimethoprim was verified by UV-visible spectrophotometry. The results confirmed that the net analyte signal standard additions method with simultaneous addition of both analytes is suitable for the simultaneous determination of sulfamethoxazole and trimethoprim in aqueous media. Moreover, applying the net analyte signal standard additions method revealed that the two drugs could be determined simultaneously with the concentration ratios of sulfamethoxazole to trimethoprim varying from 1:35 to 60:1 in the mixed samples. In addition, the limits of detections were 0.26 and 0.23 μmol L-1 for sulfamethoxazole and trimethoprim, respectively. The proposed method has been effectively applied to the simultaneous determination of sulfamethoxazole and trimethoprim in some synthetic, pharmaceutical formulation and biological fluid samples.

  18. Standard practice for digital imaging and communication in nondestructive evaluation (DICONDE) for ultrasonic test methods

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 This practice facilitates the interoperability of ultrasonic imaging equipment by specifying image data transfer and archival storage methods in commonly accepted terms. This document is intended to be used in conjunction with Practice E 2339 on Digital Imaging and Communication in Nondestructive Evaluation (DICONDE). Practice E 2339 defines an industrial adaptation of the NEMA Standards Publication titled Digital Imaging and Communications in Medicine (DICOM, see http://medical.nema.org), an international standard for image data acquisition, review, transfer and archival storage. The goal of Practice E 2339, commonly referred to as DICONDE, is to provide a standard that facilitates the display and analysis of NDE test results on any system conforming to the DICONDE standard. Toward that end, Practice E 2339 provides a data dictionary and set of information modules that are applicable to all NDE modalities. This practice supplements Practice E 2339 by providing information object definitions, information ...

  19. Development of the pressure-time method as a relative and absolute method for low-head hydraulic machines

    Energy Technology Data Exchange (ETDEWEB)

    Jonsson, Pontus [Poeyry SwedPower AB, Stockholm (Sweden); Cervantes, Michel [Luleaa Univ. of Technology, Luleaa (Sweden)

    2013-02-15

    The pressure-time method is an absolute method common for flow measurements in power plants. The method determines the flow rate by measuring the pressure and estimating the losses between two sections in the penstock during a closure of the guide vanes. The method has limitations according to the IEC41 standard, which makes it difficult to use at Swedish plants where the head is generally low. This means that there is limited experience/knowledge in Sweden on this method, where the Winter-Kennedy is usually used. Since several years, Luleaa University of Technology works actively in the development of the pressure-time method for low-head hydraulic machines with encouraging results. Focus has been in decreasing the distance between both measuring sections and evaluation of the viscous losses. Measurements were performed on a pipe test rig (D=0.3 m) in a laboratory under well controlled conditions with 7method was tested as a relative method by measuring the pressure between the free surface and a section in the penstock without knowing the exact geometry, i.e., pipe factor. Such measurements may be simple to perform as most of the inlet spiral casings have pressure taps. Furthermore, the viscous losses do not need to be accurately determined as long as they are handled similarly between the measurements. The pressure-time method may thus become an alternative to the Winter-Kennedy.

  20. On the Linear Relation between the Mean and the Standard Deviation of a Response Time Distribution

    Science.gov (United States)

    Wagenmakers, Eric-Jan; Brown, Scott

    2007-01-01

    Although it is generally accepted that the spread of a response time (RT) distribution increases with the mean, the precise nature of this relation remains relatively unexplored. The authors show that in several descriptive RT distributions, the standard deviation increases linearly with the mean. Results from a wide range of tasks from different…

  1. Transfer standard for the spectral density of relative intensity noise of optical fiber sources near 1550 nm

    Energy Technology Data Exchange (ETDEWEB)

    Obarski, Gregory E.; Splett, Jolene D.

    2001-06-01

    We have developed a transfer standard for the spectral density of relative intensity noise (RIN) of optical fiber sources near 1550 nm. Amplified spontaneous emission (ASE) from an erbium-doped fiber amplifier (EDFA), when it is optically filtered over a narrow band ({lt}5 nm), yields a stable RIN spectrum that is practically constant to several tens of gigahertz. The RIN is calculated from the power spectral density as measured with a calibrated optical spectrum analyzer. For a typical device it is {minus}110 dB/Hz, with uncertainty {le}0.12 dB/Hz. The invariance of the RIN under attenuation yields a considerable dynamic range with respect to rf noise levels. Results are compared with those from a second method that uses a distributed-feedback laser (DFB) that has a Poisson-limited RIN. Application of each method to the same RIN measurement system yields frequency-dependent calibration functions that, when they are averaged, differ by {le}0.2 dB. {copyright} 2001 Optical Society of America

  2. Standardization of a method to study the distribution of Americium in purex process

    International Nuclear Information System (INIS)

    Dapolikar, T.T.; Pant, D.K.; Kapur, H.N.; Kumar, Rajendra; Dubey, K.

    2017-01-01

    In the present work the distribution of Americium in PUREX process is investigated in various process streams. For this purpose a method has been standardized for the determination of Am in process samples. The method involves extraction of Am with associated actinides using 30% TRPO-NPH at 0.3M HNO 3 followed by selective stripping of Am from the organic phase into aqueous phase at 6M HNO 3 . The assay of aqueous phase for Am content is carried out by alpha radiometry. The investigation has revealed that 100% Am follows the HLLW route. (author)

  3. Agreement between gastrointestinal panel testing and standard microbiology methods for detecting pathogens in suspected infectious gastroenteritis: Test evaluation and meta-analysis in the absence of a reference standard.

    Science.gov (United States)

    Freeman, Karoline; Tsertsvadze, Alexander; Taylor-Phillips, Sian; McCarthy, Noel; Mistry, Hema; Manuel, Rohini; Mason, James

    2017-01-01

    Multiplex gastrointestinal pathogen panel (GPP) tests simultaneously identify bacterial, viral and parasitic pathogens from the stool samples of patients with suspected infectious gastroenteritis presenting in hospital or the community. We undertook a systematic review to compare the accuracy of GPP tests with standard microbiology techniques. Searches in Medline, Embase, Web of Science and the Cochrane library were undertaken from inception to January 2016. Eligible studies compared GPP tests with standard microbiology techniques in patients with suspected gastroenteritis. Quality assessment of included studies used tailored QUADAS-2. In the absence of a reference standard we analysed test performance taking GPP tests and standard microbiology techniques in turn as the benchmark test, using random effects meta-analysis of proportions. No study provided an adequate reference standard with which to compare the test accuracy of GPP and conventional tests. Ten studies informed a meta-analysis of positive and negative agreement. Positive agreement across all pathogens was 0.93 (95% CI 0.90 to 0.96) when conventional methods were the benchmark and 0.68 (95% CI: 0.58 to 0.77) when GPP provided the benchmark. Negative agreement was high in both instances due to the high proportion of negative cases. GPP testing produced a greater number of pathogen-positive findings than conventional testing. It is unclear whether these additional 'positives' are clinically important. GPP testing has the potential to simplify testing and accelerate reporting when compared to conventional microbiology methods. However the impact of GPP testing upon the management, treatment and outcome of patients is poorly understood and further studies are needed to evaluate the health economic impact of GPP testing compared with standard methods. The review protocol is registered with PROSPERO as CRD42016033320.

  4. Methods for preparing comparative standards and field samples for neutron activation analysis of soil

    International Nuclear Information System (INIS)

    Glasgow, D.C.; Dyer, F.F.; Robinson, L.

    1995-01-01

    One of the more difficult problems associated with comparative neutron activation analysis (CNAA) is the preparation of standards which are tailor-made to the desired irradiation and counting conditions. Frequently, there simply is not a suitable standard available commercially, or the resulting gamma spectrum is convoluted with interferences. In a recent soil analysis project, the need arose for standards which contained about 35 elements. In response, a computer spreadsheet was developed to calculate the appropriate amount of each element so that the resulting gamma spectrum is relatively free of interferences. Incorporated in the program are options for calculating all of the irradiation and counting parameters including activity produced, necessary flux/bombardment time, counting time, and appropriate source-to-detector distance. The result is multi-element standards for CNAA which have optimal concentrations. The program retains ease of use without sacrificing capability. In addition to optimized standard production, a novel soil homogenization technique was developed which is a low cost, highly efficient alternative to commercially available homogenization systems. Comparative neutron activation analysis for large scale projects has been made easier through these advancements. This paper contains details of the design and function of the NAA spreadsheet and innovative sample handling techniques. (author) 7 refs.; 5 tabs

  5. Methods for preparing comparative standards and field samples for neutron activation analysis of soil

    International Nuclear Information System (INIS)

    Glasgow, D.C.; Dyer, F.F.; Robinson, L.

    1994-01-01

    One of the more difficult problems associated with comparative neutron activation analysis (CNAA) is the preparation of standards which are tailor-made to the desired irradiation and counting conditions. Frequently, there simply is not a suitable standard available commercially, or the resulting gamma spectrum is convoluted with interferences. In a recent soil analysis project, the need arose for standards which contained about 35 elements. In response, a computer spreadsheet was developed to calculate the appropriate amount of each element so that the resulting gamma spectrum is relatively free of interferences. Incorporated in the program are options for calculating all of the irradiation and counting parameters including activity produced, necessary flux/bombardment time, counting time, and appropriate source-to-detector distance. The result is multi-element standards for CNAA which have optimal concentrations. The program retains ease of use without sacrificing capability. In addition to optimized standard production, a novel soil homogenization technique was developed which is a low cost, highly efficient alternative to commercially available homogenization systems. Comparative neutron activation analysis for large scale projects has been made easier through these advancements. This paper contains details of the design and function of the NAA spreadsheet and innovative sample handling techniques

  6. Standard Test Method for Preparing Aircraft Cleaning Compounds, Liquid Type, Water Base, for Storage Stability Testing

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2002-01-01

    1.1 This test method covers the determination of the stability in storage, of liquid, water-base chemical cleaning compounds, used to clean the exterior surfaces of aircraft. 1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  7. Condition Assessment Survey (CAS) Program. Deficiency standards and inspections methods manual: Volume 2, 0.02 Substructure

    Energy Technology Data Exchange (ETDEWEB)

    1993-05-01

    System information is given for asset determinant factor/CAS repair codes/CAS cost factors; guide sheet tool & material listing; testing methods; inspection frequency; standard system design life tables; system work breakdown structure; and general system/material data. System assembly/component deficiencies and inspection methods are given for slabs-on-grade, columns, and column fireproofing.

  8. Dietary standards for school catering in France: serving moderate quantities to improve dietary quality without increasing the food-related cost of meals.

    Science.gov (United States)

    Vieux, Florent; Dubois, Christophe; Allegre, Laëtitia; Mandon, Lionel; Ciantar, Laurent; Darmon, Nicole

    2013-01-01

    To assess the impact on food-related cost of meals to fulfill the new compulsory dietary standards for primary schools in France. A descriptive study assessed the relationship between the level of compliance with the standards of observed school meals and their food-related cost. An analytical study assessed the cost of series of meals published in professional journals, and complying or not with new dietary standards. The costs were based on prices actually paid for food used to prepare school meals. Food-related cost of meals. Parametric and nonparametric tests from a total of 42 and 120 series of 20 meals in the analytical and descriptive studies, respectively. The descriptive study indicated that meeting the standards was not related to cost. The analytical study showed that fulfilling the frequency guidelines increased the cost, whereas fulfilling the portion sizes criteria decreased it. Series of meals fully respecting the standards (ie, frequency and portion sizes) cost significantly less (-0.10 €/meal) than series not fulfilling them, because the standards recommend smaller portion sizes. Introducing portion sizes rules in dietary standards for school catering may help increase dietary quality without increasing the food cost of meals. Copyright © 2013 Society for Nutrition Education and Behavior. Published by Elsevier Inc. All rights reserved.

  9. ISO standardization in nuclear technology

    Energy Technology Data Exchange (ETDEWEB)

    Brabec, D. (Ustav pro Vyzkum, Vyrobu a Vyuziti Radioisotopu, Prague (Czechoslovakia)); Cermak, O. (Urad pro Normalizaci a Mereni, Prague (Czechoslovakia))

    1984-10-01

    The activity is described of the technical commission ISO/TC 85 which is currently divided into 4 subcommissions (SC) and 24 working groups. SC 1 ''Terminology, definitions, units, abbreviations'' has one working group. The most important document of this SC is ISO 921-1972 (Dictionary of nuclear technology). SC 2 ''Radiation protection'' has 9 working groups and has processed standards in dosimetry. SC 3 ''Technology of power reactors'' has 6 working groups and its work is related to IAEA activities within the NUSS program. SC 4 ''Technology of nuclear fuels'' has 8 working groups. SC 4 has compiled the basic standards for sealed sources and methods of testing their tightness. The results of the work of this group have been reflected into the standardization work of CMEA. A list is given of published international standards within TC 85.

  10. Standardization of Tc-99 by two methods and participation at the CCRI(II)-K2. Tc-99 comparison.

    Science.gov (United States)

    Sahagia, M; Antohe, A; Ioan, R; Luca, A; Ivan, C

    2014-05-01

    The work accomplished within the participation at the 2012 key comparison of Tc-99 is presented. The solution was standardized for the first time in IFIN-HH by two methods: LSC-TDCR and 4π(PC)β-γ efficiency tracer. The methods are described and the results are compared. For the LSC-TDCR method, the program TDCR07c, written and provided by P. Cassette, was used for processing the measurement data. The results are 2.1% higher than when applying the TDCR06b program; the higher value, calculated with the software TDCR07c, was used for reporting the final result in the comparison. The tracer used for the 4π(PC)β-γ efficiency tracer method was a standard (60)Co solution. The sources were prepared from the mixture (60)Co+(99)Tc solution and a general extrapolation curve, type: N(βTc-99)/(M)(Tc-99)=f [1-ε(Co-60)], was drawn. This value was not used for the final result of the comparison. The difference between the values of activity concentration obtained by the two methods was within the limit of the combined standard uncertainty of the difference of these two results. © 2013 Published by Elsevier Ltd.

  11. Conformal methods in general relativity

    CERN Document Server

    Valiente Kroon, Juan A

    2016-01-01

    This book offers a systematic exposition of conformal methods and how they can be used to study the global properties of solutions to the equations of Einstein's theory of gravity. It shows that combining these ideas with differential geometry can elucidate the existence and stability of the basic solutions of the theory. Introducing the differential geometric, spinorial and PDE background required to gain a deep understanding of conformal methods, this text provides an accessible account of key results in mathematical relativity over the last thirty years, including the stability of de Sitter and Minkowski spacetimes. For graduate students and researchers, this self-contained account includes useful visual models to help the reader grasp abstract concepts and a list of further reading, making this the perfect reference companion on the topic.

  12. Implementation of a standardized out-of-hospital management method for Parkinson dysphagia.

    Science.gov (United States)

    Wei, Hongying; Sun, Dongxiu; Liu, Meiping

    2017-12-01

    Our objective is to explore the effectiveness and feasibility of establishing a swallowing management clinic to implement out-of-hospital management for Parkinson disease (PD) patients with dysphagia. Two-hundred seventeen (217) voluntary PD patients with dysphagia in a PD outpatient clinic were divided into a control group with 100 people, and an experimental group with 117 people. The control group was given dysphagia rehabilitation guidance. The experimental group was presented with the standardized out-of-hospital management method as overall management and information and education materials. Rehabilitation efficiency and incidence rate of dysphagia, as well as relevant complications of both groups were compared after a 6-month intervention. Rehabilitation efficiency and the incidence rate of dysphagia including relevant complications of patients treated with the standardized out-of-hospital management were compared with those seen in the control group. The differences have distinct statistics meaning (pdysphagia complications and improve the quality of life in patients with PD.

  13. Standard Test Method for Measuring Fast-Neutron Reaction Rates by Radioactivation of Aluminum

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2011-01-01

    1.1 This test method covers procedures measuring reaction rates by the activation reaction 27Al(n,α)24Na. 1.2 This activation reaction is useful for measuring neutrons with energies above approximately 6.5 MeV and for irradiation times up to about 2 days (for longer irradiations, see Practice E261). 1.3 With suitable techniques, fission-neutron fluence rates above 106 cm−2·s−1 can be determined. 1.4 Detailed procedures for other fast neutron detectors are referenced in Practice E261. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  14. Condition Assessment Survey (CAS) Program. Deficiency standards and inspections methods manual: Volume 8, 0.08 Mechanical, Book 1

    Energy Technology Data Exchange (ETDEWEB)

    1993-05-01

    System information is presented for asset determinant factor/CAS repair codes/CAS cost factors; guide sheet too & material listing; testing methods; inspection frequency; standard system design life tables; and system work breakdown structure. Deficiency standards are given for plumbing, fire protection, heating, cooling, and special (drinking water cooling systems).

  15. Specific binding assay technique; standardization of reagent

    International Nuclear Information System (INIS)

    Huggins, K.G.; Roitt, I.M.

    1979-01-01

    The standardization of a labelled constituent, such as anti-IgE, for use in a specific binding assay method is disclosed. A labelled ligand, such as IgE, is standardized against a ligand reference substance, such as WHO standard IgE, to determine the weight of IgE protein represented by the labelled ligand. Anti-light chain antibodies are contacted with varying concentrations of the labelled ligand. The ligand is then contacted with the labelled constituent which is then quantitated in relation to the amount of ligand protein present. The preparation of 131 I-labelled IgE is described. Also disclosed is an improved specific binding assay test method for determining the potency of an allergen extract in serum from an allergic individual. The improvement involved using a parallel model system of a second complex which consisted of anti-light chain antibodies, labelled ligand and the standardized labelled constituent (anti-IgE). The amount of standardized labelled constituent bound to the ligand in the first complex was determined, as described above, and the weight of ligand inhibited by addition of soluble allergen was then used as a measure of the potency of the allergen extract. (author)

  16. Employees Training Evaluation related to the Competency Standards in the Steel and Metalworking Industry in Boyacá, Colombia

    Directory of Open Access Journals (Sweden)

    Carlos Guillermo Carreno-Bodensiek

    2016-12-01

    Full Text Available This work presents the results of a research process applied to a sample of companies in the steel and metalworking sector in Boyacá, Colombia. The active workers are evaluated over the Occupational Competency Standards related to their daily activities. It also aims to highlight the formation priority of human talent for business, according to build up a level of competitiveness. Also, seeks to meet the need to train and develop skills and competencies in the workforce, taking into account the concepts of experts about training and developing proposals for management. This research is consistent with global trends in education and the requirements of standardization of training, why diagnoses and designs are focused on the functions of the companies related to the Standards of Competency.

  17. Gauge-Independent Scales Related to the Standard Model Vacuum Instability

    CERN Document Server

    Espinosa, Jose R.; Konstandin, Thomas; Riotto, Antonio

    2017-01-01

    The measured (central) values of the Higgs and top quark masses indicate that the Standard Model (SM) effective potential develops an instability at high field values. The scale of this instability, determined as the Higgs field value at which the potential drops below the electroweak minimum, is about $10^{11}$ GeV. However, such a scale is unphysical as it is not gauge-invariant and suffers from a gauge-fixing uncertainty of up to two orders of magnitude. Subjecting our system, the SM, to several probes of the instability (adding higher order operators to the potential; letting the vacuum decay through critical bubbles; heating up the system to very high temperature; inflating it) and asking in each case physical questions, we are able to provide several gauge-invariant scales related with the Higgs potential instability.

  18. Standard test method for determination of "microwave safe for reheating" for ceramicware

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2006-01-01

    1.1 This test method determines the suitability of ceramicware for use in microwave re-heating applications. Microwave ovens are mainly used for reheating and defrosting frozen foods. Severe thermal conditions can occur while reheating foods. Typical reheating of foods requires one to five min. in the microwave at the highest power settings. Longer periods than five minutes are considered cooking. Cooking test methods and standards are not addressed in this test method. Most ceramicware is minimally absorbing of the microwave energy and will not heat up significantly. Unfortunately there are some products that absorb microwave energy to a greater extent and can become very hot in the microwave and pose a serious hazard. Additionally, the nature of microwave heating introduces radiation in a non-uniform manner producing temperature differentials in the food being cooked as well as the ceramic container holding it. The differential may become great enough to thermal shock the ware and create dangerous condition...

  19. 78 FR 12833 - Patient Protection and Affordable Care Act; Standards Related to Essential Health Benefits...

    Science.gov (United States)

    2013-02-25

    ... wellness services and chronic disease management; and pediatric services, including oral \\8\\ and vision... Act uses the terms ``dental'' and ``oral'' interchangeably when referring to the pediatric dental care... Parts 147, 155, and 156 Patient Protection and Affordable Care Act; Standards Related to Essential...

  20. Experience with nuclear safety standards development in non-governmental international organizations

    International Nuclear Information System (INIS)

    Becker, K.

    1985-01-01

    Besides the IAEA as a 'governmental' organization dealing with basic safety recommendations addressed primarily to the national regulatory bodies in developing countries, two closely related non-governmental international standards organizations have gained extensive experience in the field of nuclear standardization. Over more than 25 years since their formation, both (a) the International Organization for Standardization's (ISO) Technical Committee 85 'Nuclear Energy', in particular in its Sub-Committee 3 'Reactor Technology and Safety' and (b) the International Electrotechnical Commission's (IEC) Technical Committee 45 'Nuclear Instrumentation' have published numerous standards. A brief review is given of these, draft standards, and other documents planned to become international standards. Many of them deal with rather specialized topics typical for 'industrial' standards such as standardized procedures, instruments, methods, materials, test methods, terminology, and signs and symbols, but others are directly related to more basic safety issues. In some areas such as quality assurance, seismic aspects of siting and terminology, there has been in the past occasional overlap in the activities of the NUSS programme, IEC and ISO. Letters of Understanding have since 1981 contributed to clarifying the borderlines and to avoiding redundant efforts. Also, some experiences and problems are described arising, for example, from the harmonization of different national safety philosophies and traditions into universally accepted international standards, and the transfer of international standards into national standards systems. Finally, based on a recent comprehensive compilation of some 3300 nuclear standards and standards projects, an attempt is made to present a cost/benefit analysis and an outlook on future developments. (author)

  1. A Comparison of pical Root Resorption in Incisors after Fixed Orthodontic Treatment with Standard Edgewise and Straight Wire (MBT) Method.

    Science.gov (United States)

    Zahed Zahedani, Sm; Oshagh, M; Momeni Danaei, Sh; Roeinpeikar, Smm

    2013-09-01

    One of the major outcomes of orthodontic treatment is the apical root resorption of teeth moved during the treatment. Identifying the possible risk factors, are necessary for every orthodontist. The aim of this study was to compare the rate of apical root resorption after fixed orthodontic treatment with standard edgewise and straight wire (MBT) method, and also to evaluate other factors effecting the rate of root resorption in orthodontic treatments. In this study, parallel periapical radiographs of 127 patients imaging a total of 737 individual teeth, were collected. A total of 76 patients were treated by standard edgewise and 51 patients by straight wire method. The periapical radiographs were scanned and then the percentage of root resorption was calculated by Photoshop software. The data were analyzed by Paired-Samples t-test and the Generalized Linear Model adopting the SPSS 15.0. In patients treated with straight wire method (MBT), mean root resorption was 18.26% compared to 14.82% in patients treated with standard edgewise technique (proot resorption,statistically significant (proot resorption in this study. Having more root resorption in the straight wire method and less in the standard edgewise technique can be attributed to more root movement in pre-adjusted MBT technique due to the brackets employed in this method.

  2. Method of using a nuclear magnetic resonance spectroscopy standard

    Science.gov (United States)

    Spicer, Leonard D.; Bennett, Dennis W.; Davis, Jon F.

    1985-01-01

    (CH.sub.3).sub.3 SiNSO is produced by the reaction of ((CH.sub.3).sub.3 Si).sub.2 NH with SO.sub.2. Also produced in the reaction are ((CH.sub.3).sub.3 Si).sub.2 O and a new solid compound [NH.sub.4 ][(CH.sub.3).sub.3 SiOSO.sub.2 ]. Both (CH.sub.3).sub.3 SiNSO and [NH.sub.4 ][(CH.sub.3).sub.3 SiOSO.sub.2 ] have fluorescent properties. The reaction of the subject invention is used in a method of measuring the concentration of SO.sub.2 pollutants in gases. By the method, a sample of gas is bubbled through a solution of ((CH.sub.3).sub.3 Si).sub.2 NH, whereby any SO.sub.2 present in the gas will react to produce the two fluorescent products. The measured fluorescence of these products can then be used to calculate the concentration of SO.sub.2 in the original gas sample. The solid product [NH.sub.4 ][(CH.sub.3).sub.3 SiOSO.sub.2 ] may be used as a standard in solid state NMR spectroscopy, wherein the resonance peaks of either .sup.1 H, .sup.13 C, .sup.15 N, or .sup.29 Si may be used as a reference.

  3. Qualification of safety-related valve actuators

    International Nuclear Information System (INIS)

    Anon.

    1981-01-01

    This Standard describes the qualification of all types of power-driven valve actuators, including damper actuators, for safety-related functions in nuclear power generating stations. It may also be used to separately qualify actuator components. This Standard establishes the minimum requirements for, and guidance regarding, the methods and procedures for qualification of all safety-related functions of power-driven valve actuators

  4. Functional methods underlying classical mechanics, relativity and quantum theory

    International Nuclear Information System (INIS)

    Kryukov, A

    2013-01-01

    The paper investigates the physical content of a recently proposed mathematical framework that unifies the standard formalisms of classical mechanics, relativity and quantum theory. In the framework states of a classical particle are identified with Dirac delta functions. The classical space is ''made'' of these functions and becomes a submanifold in a Hilbert space of states of the particle. The resulting embedding of the classical space into the space of states is highly non-trivial and accounts for numerous deep relations between classical and quantum physics and relativity. One of the most striking results is the proof that the normal probability distribution of position of a macroscopic particle (equivalently, position of the corresponding delta state within the classical space submanifold) yields the Born rule for transitions between arbitrary quantum states.

  5. Standard Test Method for Gravimetric Determination of Nonvolatile Residue (NVR) in Environmentally Controlled Areas for Spacecraft

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 This test method covers the determination of nonvolatile residue (NVR) fallout in environmentally controlled areas used for the assembly, testing, and processing of spacecraft. 1.2 The NVR of interest is that which is deposited on sampling plate surfaces at room temperature: it is left to the user to infer the relationship between the NVR found on the sampling plate surface and that found on any other surfaces. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. 1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

  6. Standard Test Method for Water Absorption, Bulk Density, Apparent Porosity, and Apparent Specific Gravity of Fired Whiteware Products

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2006-01-01

    1.1 This test method covers procedures for determining water absorption, bulk density, apparent porosity, and apparent specific gravity of fired unglazed whiteware products. 1.2 This standard may involve hazardous materials, operations, and equipment. This standard does not purport to address all of the safety problems associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  7. The use of innovative teaching methods subject in training of bachelor «Standardization and metrology»

    Directory of Open Access Journals (Sweden)

    Yushchik E. V.

    2016-04-01

    Full Text Available the article considers the application of innovative teaching methods by the example of a method of collaborative learning in the laboratory practice in teaching subject «Network information technologies» to guide the preparation of 27.03.01 «Standardization and metroliya».

  8. Concept for an International Standard related to Space Weather Effects on Space Systems

    Science.gov (United States)

    Tobiska, W. Kent; Tomky, Alyssa

    There is great interest in developing an international standard related to space weather in order to specify the tools and parameters needed for space systems operations. In particular, a standard is important for satellite operators who may not be familiar with space weather. In addition, there are others who participate in space systems operations that would also benefit from such a document. For example, the developers of software systems that provide LEO satellite orbit determination, radio communication availability for scintillation events (GEO-to-ground L and UHF bands), GPS uncertainties, and the radiation environment from ground-to-space for commercial space tourism. These groups require recent historical data, current epoch specification, and forecast of space weather events into their automated or manual systems. Other examples are national government agencies that rely on space weather data provided by their organizations such as those represented in the International Space Environment Service (ISES) group of 14 national agencies. Designers, manufacturers, and launchers of space systems require real-time, operational space weather parameters that can be measured, monitored, or built into automated systems. Thus, a broad scope for the document will provide a useful international standard product to a variety of engineering and science domains. The structure of the document should contain a well-defined scope, consensus space weather terms and definitions, and internationally accepted descriptions of the main elements of space weather, its sources, and its effects upon space systems. Appendices will be useful for describing expanded material such as guidelines on how to use the standard, how to obtain specific space weather parameters, and short but detailed descriptions such as when best to use some parameters and not others; appendices provide a path for easily updating the standard since the domain of space weather is rapidly changing with new advances

  9. Water quality - Determination of tritium activity concentration - Liquid scintillation counting method (International Standard Publication ISO 9698:1989)

    International Nuclear Information System (INIS)

    Stefanik, J.

    1999-01-01

    This International Standard specifies a method for the determination of tritiated water ([ 3 H]H 2 O) activity concentration in water by liquid scintillation counting. The method is applicable to all types of water including seawater with tritium activity concentrations of up to 10 6 Bq/m 3 when using 20 ml counting vials. Below tritium activity concentrations of about 5 x 10 4 Bq/m 3[ 8], a prior enrichment step and/or the measurement of larger sample volumes can significantly improve the accuracy of the determination and lower the limit of detection. Tritium activity concentrations higher than 10 6 Bq/m 3 may be determined after appropriate dilution with distilled water of proven low tritium content. An alternative method for the determination of these higher activities involves increasing the tritium activity concentrations of the internal standard solution. The method is not applicable to the analysis of organically bound tritium; its determination requires an oxidative digestion

  10. A natural pharma standard supplement formulation to control treatment-related toxicity and oxidative stress in genitourinary cancer: a preliminary study.

    Science.gov (United States)

    Ledda, A; Belcaro, G; Dugall, M; Luzzi, R; Hosoi, M; Feragalli, B; Cotellese, R; Cosentino, V; Cosentino, M; Eggenhoffner, R; Pellizzato, M; Fratter, A; Giacomelli, L

    2017-09-01

    Oncological treatments are associated with toxicities that may decrease compliance to treatment in most genitourinary cancer patients. Supplementation with pharmaceutical-standardized supplement may be a supplementary method to control the side effects after chemo- and radiotherapy and the increased oxidative stress associated to treatments. This registry study evaluated a natural combination of supplements containing curcumin, cordyceps, and astaxanthin (Oncotris™) used as supplementary management in genitourinary cancer patients who had undergone oncological therapy. Patients with genitourinary cancers (prostate or bladder malignancies) who had undergone and completed cancer treatments (radiotherapy, chemotherapy or intravesical immunotherapy with increased oxidative stress and residual symptoms) were recruited in this registry, supplement study. Registry subjects (n = 61) freely decided to follow either a standard management (SM) (control group = 35) or SM plus oral daily supplementation (supplement group = 26). Evaluation of severity of treatment-related residual side effects, blood count test, prostate-specific antigen (PSA) test and plasma free radicals (oxidative stress) were performed at inclusion and at the end of the observational period (6 weeks). Two patients dropped out during the registry. Therefore, the analysis included 59 participants: 26 individuals in the supplementation group and 33 in the control group. In the supplement group, the intensity of signs and symptoms (treatment-related) and residual side effects significantly decreased at 6 weeks: minimal changes were observed in controls. Supplementation with Oncotris™ was associated with a significant improvement in blood cell count and with a decreased level of plasmatic PSA and oxidative stress. Naturally-derived supplements, specifically Oncotris™ (patent pending), could support the body to overcome the treatment-related toxicities - and the relative oxidative stress in cancer patients.

  11. Standard test method for isotopic analysis of hydrolyzed uranium hexafluoride and uranyl nitrate solutions by thermal ionization mass spectrometry

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2005-01-01

    1.1 This method applies to the determination of isotopic composition in hydrolyzed nuclear grade uranium hexafluoride. It covers isotopic abundance of 235U between 0.1 and 5.0 % mass fraction, abundance of 234U between 0.0055 and 0.05 % mass fraction, and abundance of 236U between 0.0003 and 0.5 % mass fraction. This test method may be applicable to other isotopic abundance providing that corresponding standards are available. 1.2 This test method can apply to uranyl nitrate solutions. This can be achieved either by transforming the uranyl nitrate solution to a uranyl fluoride solution prior to the deposition on the filaments or directly by depositing the uranyl nitrate solution on the filaments. In the latter case, a calibration with uranyl nitrate standards must be performed. 1.3 This test method can also apply to other nuclear grade matrices (for example, uranium oxides) by providing a chemical transformation to uranyl fluoride or uranyl nitrate solution. 1.4 This standard does not purport to address al...

  12. A Note on Standard Deviation and Standard Error

    Science.gov (United States)

    Hassani, Hossein; Ghodsi, Mansoureh; Howell, Gareth

    2010-01-01

    Many students confuse the standard deviation and standard error of the mean and are unsure which, if either, to use in presenting data. In this article, we endeavour to address these questions and cover some related ambiguities about these quantities.

  13. Instrumental neutron activation analysis of geochemical samples by k{sub 0} standardization method using short lived nuclides

    Energy Technology Data Exchange (ETDEWEB)

    Oura, Yasuji; Kanzaki, Chinatsu; Ebihara, Mitsuru [Tokyo Metropolitan Univ., Graduate School of Science, Tokyo (Japan)

    2003-03-01

    Mg, Al, Ca, Ti, V, and Mn contents in geochemical and cosmochemical samples were analyzed by both k{sub 0} standardization INAA and conventional INAA by a comparison method. The contents of Mg, Al, and Mn by k{sub 0} method were consistent with recommended values and ones by comparison methods. For Ti and V their values are slightly higher than recommended ones. The values by k{sub 0} method were reliable within {+-}10%. (author)

  14. Standard practice for qualification of journeyman painters for application of coatings to steel surfaces of safety-related areas in nuclear facilities

    International Nuclear Information System (INIS)

    Anon.

    1984-01-01

    This practice provides a standard qualifying method for journeyman painters to verify their proficiency and ability to attain the required quality for application of specified coatings to steel surfaces in safety-related areas in a nuclear facility. Variations or simplifications of the practice set forth herein may be appropriate for special coating work such as maintenance or qualifications of equipment suppliers shop personnel. It is not the intent of this practice to mandate a singular basis for all qualifications. Evaluation of the journeyman painter being qualified in accordance with this practice, shall be by qualified agents as specified in 4.1. Reports shall be prepared as specified in Section 5, and certification as specified in Section 6. It is the intent of this practice to judge only the ability of the journeyman painter to apply specified coatings with the proper tools and equipment. This standard may involve hazardous materials, operations, and equipment

  15. The quantitative analysis of Bowen's kale by PIXE using the internal standard

    International Nuclear Information System (INIS)

    Navarrete, V.R.; Izawa, G.; Shiokawa, T.; Kamiya, M.; Morita, S.

    1978-01-01

    The internal standard method was used for non-destructive quantitative determination of trace elements by PIXE. The uniform distribution of the internal standard element in the Bowen's kale powder sample was obtained by using homogenization technique. Eleven elements are determined quantitatively for the sample prepared into self-supporting targets having lower relative standard deviations than non-self-supporting targets. (author)

  16. Antibody reactions methods in safety standards

    International Nuclear Information System (INIS)

    Shubik, V.M.; Sirasdinov, V.G.; Zasedatelev, A.A.; Kal'nitskij, S.A.; Livshits, R.E.

    1978-01-01

    Results of determinations are presented of autoantibodies in white rats to which the radionuclides 137 Cs, 226 Ra, and 90 Sr that show different distribution patterns in the body, have been administered chronically. Autoantiboby production is found to increase when the absorbed doses are close to or exceeding seven- to tenfold the maximum permissible values. The results obtained point to the desirability of autoantibody determination in studies aimed at setting hygienic standards for the absorption of radioactive substances

  17. Multimodal nonlinear microscopy: A powerful label-free method for supporting standard diagnostics on biological tissues

    Directory of Open Access Journals (Sweden)

    Riccardo Cicchi

    2014-09-01

    Full Text Available The large use of nonlinear laser scanning microscopy in the past decade paved the way for potential clinical application of this imaging technique. Modern nonlinear microscopy techniques offer promising label-free solutions to improve diagnostic performances on tissues. In particular, the combination of multiple nonlinear imaging techniques in the same microscope allows integrating morphological with functional information in a morpho-functional scheme. Such approach provides a high-resolution label-free alternative to both histological and immunohistochemical examination of tissues and is becoming increasingly popular among the clinical community. Nevertheless, several technical improvements, including automatic scanning and image analysis, are required before the technique represents a standard diagnostic method. In this review paper, we highlight the capabilities of multimodal nonlinear microscopy for tissue imaging, by providing various examples on colon, arterial and skin tissues. The comparison between images acquired using multimodal nonlinear microscopy and histology shows a good agreement between the two methods. The results demonstrate that multimodal nonlinear microscopy is a powerful label-free alternative to standard histopathological methods and has the potential to find a stable place in the clinical setting in the near future.

  18. Gauge-independent scales related to the Standard Model vacuum instability

    International Nuclear Information System (INIS)

    Espinosa, J.R.; Garny, M.; Konstandin, T.; Riotto, A.

    2016-08-01

    The measured (central) values of the Higgs and top quark masses indicate that the Standard Model (SM) effective potential develops an instability at high field values. The scale of this instability, determined as the Higgs field value at which the potential drops below the electroweak minimum, is about 10"1"1 GeV. However, such a scale is unphysical as it is not gauge invariant and suffers from a gauge-fixing uncertainty of up to two orders of magnitude. Subjecting our system, the SM, to several probes of the instability (adding higher order operators to the potential; letting the vacuum decay through critical bubbles; heating up the system to very high temperature; inflating it) and asking in each case physical questions, we are able to provide several gauge-invariant scales related with the Higgs potential instability.

  19. Analysis of Power Transfer Efficiency of Standard Integrated Circuit Immunity Test Methods

    Directory of Open Access Journals (Sweden)

    Hai Au Huynh

    2015-01-01

    Full Text Available Direct power injection (DPI and bulk current injection (BCI methods are defined in IEC 62132-3 and IEC 62132-4 as the electromagnetic immunity test method of integrated circuits (IC. The forward power measured at the RF noise generator when the IC malfunctions is used as the measure of immunity level of the IC. However, the actual power that causes failure in ICs is different from forward power measured at the noise source. Power transfer efficiency is used as a measure of power loss of the noise injection path. In this paper, the power transfer efficiencies of DPI and BCI methods are derived and validated experimentally with immunity test setup of a clock divider IC. Power transfer efficiency varies significantly over the frequency range as a function of the test method used and the IC input impedance. For the frequency range of 15 kHz to 1 GHz, power transfer efficiency of the BCI test was constantly higher than that of the DPI test. In the DPI test, power transfer efficiency is particularly low in the lower test frequency range up to 10 MHz. When performing the IC immunity tests following the standards, these characteristics of the test methods need to be considered.

  20. Precision tests of quantum chromodynamics and the standard model

    International Nuclear Information System (INIS)

    Brodsky, S.J.; Lu, H.J.

    1995-06-01

    The authors discuss three topics relevant to testing the Standard Model to high precision: commensurate scale relations, which relate observables to each other in perturbation theory without renormalization scale or scheme ambiguity, the relationship of compositeness to anomalous moments, and new methods for measuring the anomalous magnetic and quadrupole moments of the W and Z

  1. DOE technical standards list: Department of Energy standards index

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-05-01

    This Department of Energy (DOE) technical standards list (TSL) has been prepared by the Office of Nuclear Safety Policy and Standards (EH-31) on the basis of currently available technical information. Periodic updates of this TSL will be issued as additional information is received on standardization documents being issued, adopted, or canceled by DOE. This document was prepared for use by personnel involved in the selection and use of DOE technical standards and other Government and non-Government standards. This TSL provides listings of current DOE technical standards, non-Government standards that have been adopted by DOE, other standards-related documents in which DOE has a recorded interest, and canceled DOE technical standards. Information on new DOE technical standards projects, technical standards released for coordination, recently published DOE technical standards, and activities of non-Government standards bodies that may be of interest to DOE is published monthly in Standards Actions.

  2. SGC method for predicting the standard enthalpy of formation of pure compounds from their molecular structures

    International Nuclear Information System (INIS)

    Albahri, Tareq A.; Aljasmi, Abdulla F.

    2013-01-01

    Highlights: • ΔH° f is predicted from the molecular structure of the compounds alone. • ANN-SGC model predicts ΔH° f with a correlation coefficient of 0.99. • ANN-MNLR model predicts ΔH° f with a correlation coefficient of 0.90. • Better definition of the atom-type molecular groups is presented. • The method is better than others in terms of combined simplicity, accuracy and generality. - Abstract: A theoretical method for predicting the standard enthalpy of formation of pure compounds from various chemical families is presented. Back propagation artificial neural networks were used to investigate several structural group contribution (SGC) methods available in literature. The networks were used to probe the structural groups that have significant contribution to the overall enthalpy of formation property of pure compounds and arrive at the set of groups that can best represent the enthalpy of formation for about 584 substances. The 51 atom-type structural groups listed provide better definitions of group contributions than others in the literature. The proposed method can predict the standard enthalpy of formation of pure compounds with an AAD of 11.38 kJ/mol and a correlation coefficient of 0.9934 from only their molecular structure. The results are further compared with those of the traditional SGC method based on MNLR as well as other methods in the literature

  3. 76 FR 22665 - Release of Final Document Related to the Review of the National Ambient Air Quality Standards for...

    Science.gov (United States)

    2011-04-22

    ... criteria. The revised air quality criteria reflect advances in scientific knowledge on the effects of the... National Ambient Air Quality Standards, contains staff analyses of the scientific bases for alternative... Document Related to the Review of the National Ambient Air Quality Standards for Particulate Matter AGENCY...

  4. Standardization of thermal and epithermal INAA methods for simultaneous determination of U and Th in mixed oxide samples

    International Nuclear Information System (INIS)

    Acharya, R.; Pujari, P.K.; Chandra, Ruma

    2010-01-01

    Full text: Uranium and thorium are important fuel materials for nuclear power program. In recent years utilization of thoria based fuel has assumed significance due to higher energy requirements. Thorium based mixed oxide is the proposed fuel for Advanced Heavy Water Reactors (AHWR). In this respect, studies are carried out through preparation of natural U and Th mixed oxides by powder metallurgical route, wherein composition of U and Th is specific and requires strict control in terms their contents and homogeneity in the mixture. Stringent chemical quality control necessitates compositional characterization of the fuel material i.e. accurate and precise determination of U and Th. A suitable method which does not need any chemical dissolution and yields high precision results with minima sample handling is desirable. Instrumental neutron activation analysis (INAA) using reactor neutron is the technique of choice. In view of this, INAA methods namely thermal lNAA (TNAA) (utilizing whole reactor neutrons) and epithermal INAA (ENAA) (utilizing epicadmium neutrons) were standardized for the determination of U and Th in presence of each other in mixed oxide samples. In the present work pneumatic carrier facility (PCF) of Dhruva reactor and self-serve facility of CIRUS reactor were used for TNAA and ENAA respectively. Standards, synthetic samples and mixed oxide samples prepared in cellulose matrix, were irradiated for 1 minute at PCF of Dhruva reactor and for 1 hour at CIRUS reactor under cadmium cover (0.5 mm). Radioactive assay was carried out using 40% relative efficiency HPGe detector. Peak areas under the full energy peaks were evaluated by peak fit method using the PHAST software. Both activation and daughter products of U ( 239 U, 74.6 keV and 239 Np, 277 keV) and Th ( 233 Th, 86 keV and 233 Pa, 312 keV) were used for their concentration determination. The method was validated by analyzing synthetic mixed oxide samples (6-48%U-Th mixed oxide). The % deviations

  5. Theoretical Study of Watershed Eco-Compensation Standards

    Science.gov (United States)

    Yan, Dandan; Fu, Yicheng; Liu, Biu; Sha, Jinxia

    2018-01-01

    Watershed eco-compensation is an effective way to solve conflicts over water allocation and ecological destruction problems in the exploitation of water resources. Despite an increasing interest in the topic, the researches has neglected the effect of water quality and lacked systematic calculation method. In this study we reviewed and analyzed the current literature and proposedatheoretical framework to improve the calculation of co-compensation standard.Considering the perspectives of the river ecosystems, forest ecosystems and wetland ecosystems, the benefit compensation standard was determined by the input-output corresponding relationship. Based on the opportunity costs related to limiting development and water conservation loss, the eco-compensation standard was calculated.In order to eliminate the defects of eco-compensation implementation, the improvement suggestions were proposed for the compensation standard calculation and implementation.

  6. Standardized 15N tracer method for the determination of parameters of the whole-body protein metabolism in clinical practice

    International Nuclear Information System (INIS)

    Junghans, P.; Jung, K.; Matkowitz, R.

    1984-01-01

    A standardized 15 N tracer method is described for the assessment of nitrogen and protein metabolism in healthy and pathological changed organisms. The method represents an isotope technical procedure for the application in clinical research and practice. The clinical preparation of the patient/proband by means of a standardized nutritional regime, the tracer administration (single dose) and the sampling (urine, blood), the 15 N tracer technique (sample chemistry, emissionsspectrometric isotope analysis) and the mathematical evaluation of 15 N tracer data are described. (author)

  7. Standard test method for measuring waste glass or glass ceramic durability by vapor hydration test

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 The vapor hydration test method can be used to study the corrosion of a waste forms such as glasses and glass ceramics upon exposure to water vapor at elevated temperatures. In addition, the alteration phases that form can be used as indicators of those phases that may form under repository conditions. These tests; which allow altering of glass at high surface area to solution volume ratio; provide useful information regarding the alteration phases that are formed, the disposition of radioactive and hazardous components, and the alteration kinetics under the specific test conditions. This information may be used in performance assessment (McGrail et al, 2002 (1) for example). 1.2 This test method must be performed in accordance with all quality assurance requirements for acceptance of the data. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practice...

  8. Development and validation of a HPLC method for standardization of herbal and commercial extracts of Myrcia uniflora

    Directory of Open Access Journals (Sweden)

    Andrea N. de L. Batista

    2011-06-01

    Full Text Available Myrcia uniflora Barb. Rodr., Myrtaceae, popularly known as "pedra-hume-caá" in Brazil, is sold as dry extracts in capsules or as tinctures for the treatment of diabetes mellitus. Previous phytochemical studies on this species described the occurrence of the flavonoids mearnsitrin and myricitrin. In the present study, the chromatographic profiles of M. uniflora leaves and commercial extracts were determined using HPLC-PAD. Myricitrin was used as an external standard in the development and validation of the HPLC method. The proposed method is simple, rapid and reliable and can be successfully applied in industry for standardization of herbs and phytomedicines commercialised in Brazil as "pedra-hume-caá".

  9. Development and validation of a HPLC method for standardization of herbal and commercial extracts of Myrcia uniflora

    Directory of Open Access Journals (Sweden)

    Andrea N. de L. Batista

    2011-04-01

    Full Text Available Myrcia uniflora Barb. Rodr., Myrtaceae, popularly known as "pedra-hume-caá" in Brazil, is sold as dry extracts in capsules or as tinctures for the treatment of diabetes mellitus. Previous phytochemical studies on this species described the occurrence of the flavonoids mearnsitrin and myricitrin. In the present study, the chromatographic profiles of M. uniflora leaves and commercial extracts were determined using HPLC-PAD. Myricitrin was used as an external standard in the development and validation of the HPLC method. The proposed method is simple, rapid and reliable and can be successfully applied in industry for standardization of herbs and phytomedicines commercialised in Brazil as "pedra-hume-caá".

  10. A NEW APPROACH FOR CULTURING LEMNA MINOR (DUCKWEED) AND STANDARDIZED METHOD FOR USING ATRAZINE AS A REFERENCE TOXICANT

    Science.gov (United States)

    Lemna minor (Duckweed) is commonly used in aquatic toxicity investigations. Methods for culturing and testing with reference toxicants, such as atrazine, are somewhat variable among researchers. Our goal was to develop standardized methods of culturing and testing for use with L....

  11. Next-generation mass standard using the superconducting magnetic levitation method; Chodendo jiki fujoho ni yoru jisedai shitsuryo hyojun

    Energy Technology Data Exchange (ETDEWEB)

    Miki, Yukinobu; Shiota, Fuyuhiko; Fujii, Yusaku [National Research Laboratory of Metrology, Tsukuba (Japan)

    1999-10-25

    The Present mass standard based on the prototype of the kilogram has some serious problems such as surface contamination and unrecoverablity in the case of damage or loss. Research on monitoring and finally replacing the present mass standard are therefore encouraged and some approaches have been proposed. In this article, the superconducting magnetic levitation method, which is one of the approaches that also makes use of the unique properties of superconductivity, is reviewed together with a brief description about mass and electric standards. (author)

  12. Identification of Water Quality Significant Parameter with Two Transformation/Standardization Methods on Principal Component Analysis and Scilab Software

    Directory of Open Access Journals (Sweden)

    Jovan Putranda

    2016-09-01

    Full Text Available Water quality monitoring is prone to encounter error on its recording or measuring process. The monitoring on river water quality not only aims to recognize the water quality dynamic, but also to evaluate the data to create river management policy and water pollution in order to maintain the continuity of human health or sanitation requirement, and biodiversity preservation. Evaluation on water quality monitoring needs to be started by identifying the important water quality parameter. This research objected to identify the significant parameters by using two transformation or standardization methods on water quality data, which are the river Water Quality Index, WQI (Indeks Kualitas Air, Sungai, IKAs transformation or standardization method and transformation or standardization method with mean 0 and variance 1; so that the variability of water quality parameters could be aggregated with one another. Both of the methods were applied on the water quality monitoring data which its validity and reliability have been tested. The PCA, Principal Component Analysis (Analisa Komponen Utama, AKU, with the help of Scilab software, has been used to process the secondary data on water quality parameters of Gadjah Wong river in 2004-2013, with its validity and reliability has been tested. The Scilab result was cross examined with the result from the Excel-based Biplot Add In software. The research result showed that only 18 from total 35 water quality parameters that have passable data quality. The two transformation or standardization data methods gave different significant parameter type and amount result. On the transformation or standardization mean 0 variances 1, there were water quality significant parameter dynamic to mean concentration of each water quality parameters, which are TDS, SO4, EC, TSS, NO3N, COD, BOD5, Grease Oil and NH3N. On the river WQI transformation or standardization, the water quality significant parameter showed the level of

  13. ExSTA: External Standard Addition Method for Accurate High-Throughput Quantitation in Targeted Proteomics Experiments.

    Science.gov (United States)

    Mohammed, Yassene; Pan, Jingxi; Zhang, Suping; Han, Jun; Borchers, Christoph H

    2018-03-01

    Targeted proteomics using MRM with stable-isotope-labeled internal-standard (SIS) peptides is the current method of choice for protein quantitation in complex biological matrices. Better quantitation can be achieved with the internal standard-addition method, where successive increments of synthesized natural form (NAT) of the endogenous analyte are added to each sample, a response curve is generated, and the endogenous concentration is determined at the x-intercept. Internal NAT-addition, however, requires multiple analyses of each sample, resulting in increased sample consumption and analysis time. To compare the following three methods, an MRM assay for 34 high-to-moderate abundance human plasma proteins is used: classical internal SIS-addition, internal NAT-addition, and external NAT-addition-generated in buffer using NAT and SIS peptides. Using endogenous-free chicken plasma, the accuracy is also evaluated. The internal NAT-addition outperforms the other two in precision and accuracy. However, the curves derived by internal vs. external NAT-addition differ by only ≈3.8% in slope, providing comparable accuracies and precision with good CV values. While the internal NAT-addition method may be "ideal", this new external NAT-addition can be used to determine the concentration of high-to-moderate abundance endogenous plasma proteins, providing a robust and cost-effective alternative for clinical analyses or other high-throughput applications. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. British Standard method for determination of ISO speed and average gradient of direct-exposure medical and dental radiographic film/process combinations

    International Nuclear Information System (INIS)

    1983-01-01

    Under the direction of the Cinematography and Photography Standards Committee, a British Standard method has been prepared for determining ISO speed and average gradient of direct-exposure medical and dental radiographic film/film-process combinations. The method determines the speed and gradient, i.e. contrast, of the X-ray films processed according to their manufacturer's recommendations. (U.K.)

  15. Social network extraction based on Web: 1. Related superficial methods

    Science.gov (United States)

    Khairuddin Matyuso Nasution, Mahyuddin

    2018-01-01

    Often the nature of something affects methods to resolve the related issues about it. Likewise, methods to extract social networks from the Web, but involve the structured data types differently. This paper reveals several methods of social network extraction from the same sources that is Web: the basic superficial method, the underlying superficial method, the description superficial method, and the related superficial methods. In complexity we derive the inequalities between methods and so are their computations. In this case, we find that different results from the same tools make the difference from the more complex to the simpler: Extraction of social network by involving co-occurrence is more complex than using occurrences.

  16. Standard test method for uranium by Iron (II) reduction in phosphoric acid followed by chromium (VI) titration in the presence of vanadium

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2011-01-01

    1.1 This test method, commonly referred to as the Modified Davies and Gray technique, covers the titration of uranium in product, fuel, and scrap materials after the material is dissolved. The test method is versatile and has been ruggedness tested. With appropriate sample preparation, this test method can give precise and unbiased uranium assays over a wide variety of material types (1, 2). Details of the titration procedure in the presence of plutonium with appropriate modifications are given in Test Method C1204. 1.2 Uranium levels titrated are usually 20 to 50 mg, but up to 200 mg uranium can be titrated using the reagent volumes stated in this test method. 1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determ...

  17. Studies and research concerning BNFP: cask handling equipment standardization

    International Nuclear Information System (INIS)

    McCreery, P.N.

    1980-10-01

    This report covers the activities of one of the sub-tasks within the Spent LWR Fuel Transportation Receiving, Handling, and Storage program. The sub-task is identified as Cask Handling Equipment Standardization. The objective of the sub-task specifies: investigate and identify opportunities for standardization of cask interface equipment. This study will examine the potential benefits of standardized yokes, decontamination barriers and special tools, and, to the extent feasible, standardized methods and software for handling the variety of casks presently available in the US fleet. The result of the investigations is a compilation of reports that are related by their common goal of reducing cask turnaround time

  18. Examination of fast reactor fuels, FBR analytical quality assurance standards and methods, and analytical methods development: irradiation tests. Progress report, April 1--June 30, 1976, and FY 1976

    International Nuclear Information System (INIS)

    Baker, R.D.

    1976-08-01

    Characterization of unirradiated and irradiated LMFBR fuels by analytical chemistry methods will continue, and additional methods will be modified and mechanized for hot cell application. Macro- and microexaminations will be made on fuel and cladding using the shielded electron microprobe, emission spectrograph, radiochemistry, gamma scanner, mass spectrometers, and other analytical facilities. New capabilities will be developed in gamma scanning, analyses to assess spatial distributions of fuel and fission products, mass spectrometric measurements of burnup and fission gas constituents and other chemical analyses. Microstructural analyses of unirradiated and irradiated materials will continue using optical and electron microscopy and autoradiographic and x-ray techniques. Analytical quality assurance standards tasks are designed to assure the quality of the chemical characterizations necessary to evaluate reactor components relative to specifications. Tasks include: (1) the preparation and distribution of calibration materials and quality control samples for use in quality assurance surveillance programs, (2) the development of and the guidance in the use of quality assurance programs for sampling and analysis, (3) the development of improved methods of analysis, and (4) the preparation of continuously updated analytical method manuals. Reliable analytical methods development for the measurement of burnup, oxygen-to-metal (O/M) ratio, and various gases in irradiated fuels is described

  19. Analytical methods relating to mineral matter in coal and ash from coal combustion

    Energy Technology Data Exchange (ETDEWEB)

    Creelman, R.A. [Ultra-Systems Technology Pty. Ltd., Indooroopilly, Qld. (Australia)

    2002-07-01

    The paper begins by describing the minerals that occur in coal, as well as trace elements. The testing methods that are then described include those that are in the main the standard tools for the examination and assessment of minerals in coal and ash. The techniques discussed include optical and beam techniques, X-ray methods and a variety of other useful methods. 12 refs.

  20. Decommissioning standards

    International Nuclear Information System (INIS)

    Crofford, W.N.

    1980-01-01

    EPA has agreed to establish a series of environmental standards for the safe disposal of radioactive waste through participation in the Interagency Review Group on Nuclear Waste Management (IRG). One of the standards required under the IRG is the standard for decommissioning of radioactive contaminated sites, facilities, and materials. This standard is to be proposed by December 1980 and promulgated by December 1981. Several considerations are important in establishing these standards. This study includes discussions of some of these considerations and attempts to evaluate their relative importance. Items covered include: the form of the standards, timing for decommissioning, occupational radiation protection, costs and financial provisions. 4 refs

  1. Comparison of different methods for activation analysis of geological and pedological samples: Reactor and epithermal neutron activation, relative and monostandard method

    International Nuclear Information System (INIS)

    Alian, A.; Sansoni, B.

    1980-04-01

    Using purely instrumental methods, a comparative study is presented on neutron activation analysis of rock and soil samples by whole reactor neutron spectrum and epithermal neutrons with both relative and monostandard procedures. The latter procedure used with epithermal neutron activation analysis of soil samples necessitated the use of the 'effective resonance integrals' which were determined experimentally. The incorporation of the #betta# factor, representing deviation of reactor epithermal neutron flux from 1/E law, is developed in the present work. The main criteria for the choice of one or more of the procedures studied for a given purpose are also indicated. Analysis of 15 trace elements, Ca and Fe in the standard Japanese granite JG-1 using monostandard epithermal neutron activation gave results in good agreement with the average literature values. (orig./RB) [de

  2. Liquid scintillation counting standardization of ''125 I in organic and inorganic samples by the CIEMAT/NIST method

    International Nuclear Information System (INIS)

    Rodriguez Barquero, L.; Grau Malonda, A.; Los Arcos Merino, J.M.; Grau Carles, A.

    1994-01-01

    The liquid scintillation counting standardization of organic and inorganic samples of ''125 I by the CIEMAT/NIST method using five different scintillators is described. The discrepancies between experimental and computed efficiencies are lower than 1.4% and 1.7%, for inorganic and organic samples, respectively, in the interval 421-226 of quenching parameter. Both organic and inorganic solutions have been standardized in terms of activity concentration to an overall uncertainty of 0.76%

  3. Standard practice for digital imaging and communication nondestructive evaluation (DICONDE) for computed radiography (CR) test methods

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This practice facilitates the interoperability of computed radiography (CR) imaging and data acquisition equipment by specifying image data transfer and archival storage methods in commonly accepted terms. This practice is intended to be used in conjunction with Practice E2339 on Digital Imaging and Communication in Nondestructive Evaluation (DICONDE). Practice E2339 defines an industrial adaptation of the NEMA Standards Publication titled Digital Imaging and Communications in Medicine (DICOM, see http://medical.nema.org), an international standard for image data acquisition, review, storage and archival storage. The goal of Practice E2339, commonly referred to as DICONDE, is to provide a standard that facilitates the display and analysis of NDE results on any system conforming to the DICONDE standard. Toward that end, Practice E2339 provides a data dictionary and a set of information modules that are applicable to all NDE modalities. This practice supplements Practice E2339 by providing information objec...

  4. Instrumental charged-particle activation analysis of several selected elements in biological materials using the internal standard method

    International Nuclear Information System (INIS)

    Yagi, M.; Masumoto, K.

    1987-01-01

    In order to study instrumental charged-particle activation analysis using the internal standard method, simultaneous determinations of several selected elements such as Ca, Ti, V, Fe, Zn, As, Sr, Zr and Mo, in oyster tissue, brewer's yeast and mussel were carried out by using the respective (p, n) reactions and a personal computer-based gamma-ray spectrometer equipped with a micro-robot for sample changing. In the determination constant amounts of Y and La were added to the sample and comparative standard as exotic internal standards. As a result, it was demonstrated that concentrations of the above elements could be determined accurately and precisely. (author)

  5. A Method for Developing Standard Patient Education Program.

    Science.gov (United States)

    Lura, Carolina Bryne; Hauch, Sophie Misser Pallesgaard; Gøeg, Kirstine Rosenbeck; Pape-Haugaard, Louise

    2018-01-01

    In Denmark, patients being treated on Haematology Outpatients Departments get instructed to self-manage their blood sample collection from Central Venous Catheter (CVC). However, this is a complex and risky procedure, which can jeopardize patient safety. The aim of the study was to suggest a method for developing standard digital patient education programs for patients in self-administration of blood samples drawn from CVC. The Design Science Research Paradigm was used to develop a digital patient education program, called PAVIOSY, to increase patient safety during execution of the blood sample collection procedure by using videos for teaching as well as procedural support. A step-by-step guide was developed and used as basis for making the videos. Quality assurance through evaluation with a nurse was conducted on both the step-by-step guide and the videos. The quality assurance evaluation of the videos showed; 1) Errors due to the order of the procedure can be determined by reviewing the videos despite that the guide was followed. 2) Videos can be used to identify errors - important for patient safety - in the procedure, which are not identifiable in a written script. To ensure correct clinical content of the educational patient system, health professionals must be engaged early in the development of content and design phase.

  6. Neutron activation analysis of archaeological artifacts using the conventional relative method: a realistic approach for analysis of large samples

    International Nuclear Information System (INIS)

    Bedregal, P.S.; Mendoza, A.; Montoya, E.H.; Cohen, I.M.; Universidad Tecnologica Nacional, Buenos Aires; Oscar Baltuano

    2012-01-01

    A new approach for analysis of entire potsherds of archaeological interest by INAA, using the conventional relative method, is described. The analytical method proposed involves, primarily, the preparation of replicates of the original archaeological pottery, with well known chemical composition (standard), destined to be irradiated simultaneously, in a well thermalized external neutron beam of the RP-10 reactor, with the original object (sample). The basic advantage of this proposal is to avoid the need of performing complicated effect corrections when dealing with large samples, due to neutron self shielding, neutron self-thermalization and gamma ray attenuation. In addition, and in contrast with the other methods, the main advantages are the possibility of evaluating the uncertainty of the results and, fundamentally, validating the overall methodology. (author)

  7. Application of Monte Carlo Method for Evaluation of Uncertainties of ITS-90 by Standard Platinum Resistance Thermometer

    Science.gov (United States)

    Palenčár, Rudolf; Sopkuliak, Peter; Palenčár, Jakub; Ďuriš, Stanislav; Suroviak, Emil; Halaj, Martin

    2017-06-01

    Evaluation of uncertainties of the temperature measurement by standard platinum resistance thermometer calibrated at the defining fixed points according to ITS-90 is a problem that can be solved in different ways. The paper presents a procedure based on the propagation of distributions using the Monte Carlo method. The procedure employs generation of pseudo-random numbers for the input variables of resistances at the defining fixed points, supposing the multivariate Gaussian distribution for input quantities. This allows taking into account the correlations among resistances at the defining fixed points. Assumption of Gaussian probability density function is acceptable, with respect to the several sources of uncertainties of resistances. In the case of uncorrelated resistances at the defining fixed points, the method is applicable to any probability density function. Validation of the law of propagation of uncertainty using the Monte Carlo method is presented on the example of specific data for 25 Ω standard platinum resistance thermometer in the temperature range from 0 to 660 °C. Using this example, we demonstrate suitability of the method by validation of its results.

  8. Listening to Early Career Teachers: How Can Elementary Mathematics Methods Courses Better Prepare Them to Utilize Standards-Based Practices in Their Classrooms?

    Science.gov (United States)

    Coester, Lee Anne

    2010-01-01

    This study was designed to gather input from early career elementary teachers with the goal of finding ways to improve elementary mathematics methods courses. Multiple areas were explored including the degree to which respondents' elementary mathematics methods course focused on the NCTM Process Standards, the teachers' current standards-based…

  9. [Possible relation between clinical guidelines and legal standard of medicine].

    Science.gov (United States)

    Furukawa, Toshiharu; Kitagawa, Yuko

    2010-10-01

    Legal standard of medicine is not equal across the all kinds of medical institutions. Each medical institution is required its respective standard of medicine in which its doctors are expected to have studied medical informations, which have been spread among medical institutions with similar characteristics. Therefore, in principle, clinical guidelines for the treatment of a disease formed by public committees do not directly become the medical standards of respective disease treatment. However, doctors would be legally required to practice medicine with reference to the clinical guidelines because medical informations, mediated by internet or many kinds of media, have been spread very fast to all medical institutions these days. Moreover, doctors would be required to inform their patients of non-standardized new treatments, even if such treatments are not listed in clinical guidelines in case patients have special concern about new treat-

  10. Effects of the Occupational Safety and Health Administration's control of hazardous energy (lockout/tagout) standard on rates of machinery-related fatal occupational injury.

    Science.gov (United States)

    Bulzacchelli, Maria T; Vernick, Jon S; Webster, Daniel W; Lees, Peter S J

    2007-10-01

    To evaluate the impact of the United States' federal Occupational Safety and Health Administration's control of hazardous energy (lockout/tagout) standard on rates of machinery-related fatal occupational injury. The standard, which took effect in 1990, requires employers in certain industries to establish an energy control program and sets minimum criteria for energy control procedures, training, inspections, and hardware. An interrupted time-series design was used to determine the standard's effect on fatality rates. Machinery-related fatalities, obtained from the National Traumatic Occupational Fatalities surveillance system for 1980 through 2001, were used as a proxy for lockout/tagout-related fatalities. Linear regression was used to control for changes in demographic and economic factors. The average annual crude rate of machinery-related fatalities in manufacturing changed little from 1980 to 1989, but declined by 4.59% per year from 1990 to 2001. However, when controlling for demographic and economic factors, the regression model estimate of the standard's effect is a small, non-significant increase of 0.05 deaths per 100 000 production worker full-time equivalents (95% CI -0.14 to 0.25). When fatality rates in comparison groups that should not have been affected by the standard are incorporated into the analysis, there is still no significant change in the rate of machinery-related fatalities in manufacturing. There is no evidence that the lockout/tagout standard decreased fatality rates relative to other trends in occupational safety over the study period. A possible explanation is voluntary use of lockout/tagout by some employers before introduction of the standard and low compliance by other employers after.

  11. Effects of the Occupational Safety and Health Administration's control of hazardous energy (lockout/tagout) standard on rates of machinery‐related fatal occupational injury

    Science.gov (United States)

    Bulzacchelli, Maria T; Vernick, Jon S; Webster, Daniel W; Lees, Peter S J

    2007-01-01

    Objective To evaluate the impact of the United States' federal Occupational Safety and Health Administration's control of hazardous energy (lockout/tagout) standard on rates of machinery‐related fatal occupational injury. The standard, which took effect in 1990, requires employers in certain industries to establish an energy control program and sets minimum criteria for energy control procedures, training, inspections, and hardware. Design An interrupted time‐series design was used to determine the standard's effect on fatality rates. Machinery‐related fatalities, obtained from the National Traumatic Occupational Fatalities surveillance system for 1980 through 2001, were used as a proxy for lockout/tagout‐related fatalities. Linear regression was used to control for changes in demographic and economic factors. Results The average annual crude rate of machinery‐related fatalities in manufacturing changed little from 1980 to 1989, but declined by 4.59% per year from 1990 to 2001. However, when controlling for demographic and economic factors, the regression model estimate of the standard's effect is a small, non‐significant increase of 0.05 deaths per 100 000 production worker full‐time equivalents (95% CI −0.14 to 0.25). When fatality rates in comparison groups that should not have been affected by the standard are incorporated into the analysis, there is still no significant change in the rate of machinery‐related fatalities in manufacturing. Conclusions There is no evidence that the lockout/tagout standard decreased fatality rates relative to other trends in occupational safety over the study period. A possible explanation is voluntary use of lockout/tagout by some employers before introduction of the standard and low compliance by other employers after. PMID:17916891

  12. On one method of realization of commutation relation algebra

    International Nuclear Information System (INIS)

    Sveshnikov, K.A.

    1983-01-01

    Method for constructing the commulation relation representations based on the purely algebraic construction of joined algebraic representation with specially selected composition law has been suggested9 Purely combinatorial construction realizing commulation relations representation has been obtained proceeding from formal equivalence of operatopr action on vector and adding a simbol to a sequences of symbols. The above method practically has the structure of calculating algorithm, which assigns some rule of ''word'' formation of an initial set of ''letters''. In other words, a computer language with definite relations between words (an analogy between quantum mechanics and computer linguistics has been applied)

  13. DETECTION OF MICROVASCULAR COMPLICATIONS OF TYPE 2 DIABETES BY EZSCAN AND ITS COMPARISON WITH STANDARD SCREENING METHODS

    Directory of Open Access Journals (Sweden)

    Sarita Bajaj

    2016-08-01

    Full Text Available BACKGROUND EZSCAN is a new, noninvasive technique to detect sudomotor dysfunction and thus neuropathy in diabetes patients at an early stage. It further predicts chances of development of other microvascular complications. In this study, we evaluated EZSCAN for detection of microvascular complications in Type 2 diabetes patients and compared accuracy of EZSCAN with standard screening methods. MATERIALS AND METHODS 104 known diabetes patients, 56 males and 48 females, were studied. All cases underwent the EZSCAN test, Nerve Conduction Study (NCS test, Vibration perception threshold test (VPT, Monofilament test, Fundus examination and Urine micral test. The results of EZSCAN were compared with standard screening methods. The data has been analysed and assessed by applying appropriate statistical tests within different groups. RESULTS Mean age of the subjects was 53.5 ± 11.4 years. For detection of diabetic neuropathy, sensitivity and specificity of EZSCAN was found to be 77.0 % and 95.3%, respectively. Odd’s ratio (OR was 68.82 with p < 0.0001. AUC in ROC curve was 0.930. Sensitivity and specificity of EZSCAN for detection of nephropathy were 67.1% and 94.1%, respectively. OR = 32.69 with p < 0.0001. AUC was 0.926. Sensitivity of EZSCAN for detection of retinopathy was 90% while specificity is 70.3%. OR = 21.27; p< 0.0001. AUC came out to be 0.920. CONCLUSION Results of EZSCAN test compared significantly to the standard screening methods for the detection of microvascular complications of diabetes and can be used as a simple, noninvasive and quick method to detect microvascular complications of diabetes.

  14. Study on Quality Standard of Processed Curcuma Longa Radix

    Directory of Open Access Journals (Sweden)

    Zhimin Chen

    2017-01-01

    Full Text Available To control the quality of Curcuma Longa Radix by establishing quality standards, this paper increased the contents of extract and volatile oil determination. Meanwhile, the curcumin was selected as the internal marker, and the relative correlation factors (RCFs of demethoxycurcumin and bisdemethoxycurcumin were established by high performance liquid chromatography (HPLC. The contents of multicomponents were calculated based on their RCFs. The rationality and feasibility of the methods were evaluated by comparison of the quantitative results between external standard method (ESM and quantitative analysis of multicomponents by single-marker (QAMS. Ethanol extracts ranged from 9.749 to 15.644% and the mean value was 13.473%. The volatile oil ranged from 0.45 to 0.90 mL/100 g and the mean value was 0.66 mL/100 g. This method was accurate and feasible and could provide a reference for further comprehensive and effective control of the quality standard of Curcuma Longa Radix and its processed products.

  15. Study on Quality Standard of Processed Curcuma Longa Radix

    Science.gov (United States)

    Zhao, Yongfeng; Quan, Liang; Zhou, Haiting; Cao, Dong; Li, Wenbing; Yang, Zhuo

    2017-01-01

    To control the quality of Curcuma Longa Radix by establishing quality standards, this paper increased the contents of extract and volatile oil determination. Meanwhile, the curcumin was selected as the internal marker, and the relative correlation factors (RCFs) of demethoxycurcumin and bisdemethoxycurcumin were established by high performance liquid chromatography (HPLC). The contents of multicomponents were calculated based on their RCFs. The rationality and feasibility of the methods were evaluated by comparison of the quantitative results between external standard method (ESM) and quantitative analysis of multicomponents by single-marker (QAMS). Ethanol extracts ranged from 9.749 to 15.644% and the mean value was 13.473%. The volatile oil ranged from 0.45 to 0.90 mL/100 g and the mean value was 0.66 mL/100 g. This method was accurate and feasible and could provide a reference for further comprehensive and effective control of the quality standard of Curcuma Longa Radix and its processed products. PMID:29375640

  16. Standardization work by ASTM and DIN concerning test methods for metallic materials - comparative assessment with regard for practice

    International Nuclear Information System (INIS)

    Gerischer, K.

    1986-01-01

    The article explains the significant role of ASTM and marks out basic elements of the specification system of ASTM standards. Usefulness in practice is taken as the main criterion for the subsequent comparison of ASTM or DIN activities and procedures, and results, for standardization in the field of test methods for metallic materials. The main differences are shown to exist with regard to tropicality of test standards, presentation of useful information and background knowledge, and importance attached to formal questions. ASTM standardization work is shown to be more up-to-date, contain more information, and to be less concerned with formal matters. A closer cooperation between ASTM and DIN is strongly recommended. (orig.) [de

  17. Relating road salt to exceedances of the water quality standard for chloride in New Hampshire streams.

    Science.gov (United States)

    Trowbridge, Philip R; Kahl, J Steve; Sassan, Dari A; Heath, Douglas L; Walsh, Edward M

    2010-07-01

    Six watersheds in New Hampshire were studied to determine the effects of road salt on stream water quality. Specific conductance in streams was monitored every 15 min for one year using dataloggers. Chloride concentrations were calculated from specific conductance using empirical relationships. Stream chloride concentrations were directly correlated with development in the watersheds and were inversely related to streamflow. Exceedances of the EPA water quality standard for chloride were detected in the four watersheds with the most development. The number of exceedances during a year was linearly related to the annual average concentration of chloride. Exceedances of the water quality standard were not predicted for streams with annual average concentrations less than 102 mg L(-1). Chloride was imported into three of the watersheds at rates ranging from 45 to 98 Mg Cl km(-2) yr(-1). Ninety-one percent of the chloride imported was road salt for deicing roadways and parking lots. A simple, mass balance equation was shown to predict annual average chloride concentrations from streamflow and chloride import rates to the watershed. This equation, combined with the apparent threshold for exceedances of the water quality standard, can be used for screening-level TMDLs for road salt in impaired watersheds.

  18. Guidelines for drafting national and international seismic standards

    International Nuclear Information System (INIS)

    Podrouzek, J.

    1989-01-01

    The main principles of engineering reliability are discussed in relation to the formation of seismic standards. The basic recommendations of the International Association of Earthquake Engineering in the field of inspection and earthquake resistance evaluation of engineering structures and systems are characterized. Attention is also paid to efforts aimed at a unification of standards and regulations, based on the fact that quasistatic and response spectra methods are largely common to the standards amd regulations. However, as the potential of computer techniques increases, more complex computer programs appear and the amount of tenuous input data increases, and this can affect the quality of seismic inspections. (Z.M.). 5 figs., 1 ref

  19. FY 1999 project on the development of new industry support type international standards. Standardization of evaluation method of the genetic testing system; 1999 nendo shinki sangyo shiengata kokusai hyojunka kaihatsu jigyo seika hokokusho. Idenshi kensa system no hyoka hoho no hyojunka

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-03-01

    Aiming at applying standards as international standards, an experimental study was conducted on the standardization of the genetic testing system in Japan and abroad. The FY 1999 results were summarized. As to the unification of testing data processing, analysis of the present state and experimental study were made on the following: sampling method for appropriate testing, selection of anti-coagulants, method to preserve specimens, method to transport them, description of clinical observations in test request paper, method to evaluate performance of test reagents including restriction enzyme, temperature calibration method for equipment, sterilization method, incineration method of specimens, long-term storage of DNA samples, etc. The results were proposed as standard operation procedures after study/discussion at the comprehensive survey committee. Concerning the setting of criteria values in data analysis and the standardization of report form, survey/study were conducted also on ethical/legal/social problems from an aspect of privacy protection of patients. As a result, a total system from the reception of genetic testing to the report making was prepared. (NEDO)

  20. Multi-domain comparison of safety standards

    International Nuclear Information System (INIS)

    Baufreton, Ph.; Derrien, J.C.; Ricque, B.; Blanquart, J.P.; Boulanger, J.L.; Delseny, H.; Gassino, J.; Ladier, G.; Ledinot, E.; Leeman, M.; Quere, Ph.

    2011-01-01

    This paper presents an analysis of safety standards and their implementation in certification strategies from different domains such as aeronautics, automation, automotive, nuclear, railway and space. This work, performed in the context of the CG2E ('Club des Grandes Entreprises de l'Embarque'), aims at identifying the main similarities and dissimilarities, for potential cross-domain harmonization. We strive to find the most comprehensive 'trans-sectorial' approach, within a large number of industrial domains. Exhibiting the 'true goals' of their numerous applicable standards, related to the safety of system and software, is a first important step towards harmonization, sharing common approaches, methods and tools whenever possible. (authors)