WorldWideScience

Sample records for refractive error quality

  1. Uncorrected refractive errors.

    Science.gov (United States)

    Naidoo, Kovin S; Jaggernath, Jyoti

    2012-01-01

    Global estimates indicate that more than 2.3 billion people in the world suffer from poor vision due to refractive error; of which 670 million people are considered visually impaired because they do not have access to corrective treatment. Refractive errors, if uncorrected, results in an impaired quality of life for millions of people worldwide, irrespective of their age, sex and ethnicity. Over the past decade, a series of studies using a survey methodology, referred to as Refractive Error Study in Children (RESC), were performed in populations with different ethnic origins and cultural settings. These studies confirmed that the prevalence of uncorrected refractive errors is considerably high for children in low-and-middle-income countries. Furthermore, uncorrected refractive error has been noted to have extensive social and economic impacts, such as limiting educational and employment opportunities of economically active persons, healthy individuals and communities. The key public health challenges presented by uncorrected refractive errors, the leading cause of vision impairment across the world, require urgent attention. To address these issues, it is critical to focus on the development of human resources and sustainable methods of service delivery. This paper discusses three core pillars to addressing the challenges posed by uncorrected refractive errors: Human Resource (HR) Development, Service Development and Social Entrepreneurship.

  2. Uncorrected refractive errors

    Directory of Open Access Journals (Sweden)

    Kovin S Naidoo

    2012-01-01

    Full Text Available Global estimates indicate that more than 2.3 billion people in the world suffer from poor vision due to refractive error; of which 670 million people are considered visually impaired because they do not have access to corrective treatment. Refractive errors, if uncorrected, results in an impaired quality of life for millions of people worldwide, irrespective of their age, sex and ethnicity. Over the past decade, a series of studies using a survey methodology, referred to as Refractive Error Study in Children (RESC, were performed in populations with different ethnic origins and cultural settings. These studies confirmed that the prevalence of uncorrected refractive errors is considerably high for children in low-and-middle-income countries. Furthermore, uncorrected refractive error has been noted to have extensive social and economic impacts, such as limiting educational and employment opportunities of economically active persons, healthy individuals and communities. The key public health challenges presented by uncorrected refractive errors, the leading cause of vision impairment across the world, require urgent attention. To address these issues, it is critical to focus on the development of human resources and sustainable methods of service delivery. This paper discusses three core pillars to addressing the challenges posed by uncorrected refractive errors: Human Resource (HR Development, Service Development and Social Entrepreneurship.

  3. Psychometric properties of the national eye institute refractive error correction quality-of-life questionnaire among Iranian patients

    Directory of Open Access Journals (Sweden)

    Amir H Pakpour

    2013-01-01

    Conclusions: The Iranian version of the NEI-RQL-42 is a valid and reliable instrument to assess refractive error correction quality-of-life in Iranian patients. Moreover this questionnaire can be used to evaluate the effectiveness of interventions in patients with refractive errors.

  4. The quality of systematic reviews about interventions for refractive error can be improved: a review of systematic reviews.

    Science.gov (United States)

    Mayo-Wilson, Evan; Ng, Sueko Matsumura; Chuck, Roy S; Li, Tianjing

    2017-09-05

    Systematic reviews should inform American Academy of Ophthalmology (AAO) Preferred Practice Pattern® (PPP) guidelines. The quality of systematic reviews related to the forthcoming Preferred Practice Pattern® guideline (PPP) Refractive Errors & Refractive Surgery is unknown. We sought to identify reliable systematic reviews to assist the AAO Refractive Errors & Refractive Surgery PPP. Systematic reviews were eligible if they evaluated the effectiveness or safety of interventions included in the 2012 PPP Refractive Errors & Refractive Surgery. To identify potentially eligible systematic reviews, we searched the Cochrane Eyes and Vision United States Satellite database of systematic reviews. Two authors identified eligible reviews and abstracted information about the characteristics and quality of the reviews independently using the Systematic Review Data Repository. We classified systematic reviews as "reliable" when they (1) defined criteria for the selection of studies, (2) conducted comprehensive literature searches for eligible studies, (3) assessed the methodological quality (risk of bias) of the included studies, (4) used appropriate methods for meta-analyses (which we assessed only when meta-analyses were reported), (5) presented conclusions that were supported by the evidence provided in the review. We identified 124 systematic reviews related to refractive error; 39 met our eligibility criteria, of which we classified 11 to be reliable. Systematic reviews classified as unreliable did not define the criteria for selecting studies (5; 13%), did not assess methodological rigor (10; 26%), did not conduct comprehensive searches (17; 44%), or used inappropriate quantitative methods (3; 8%). The 11 reliable reviews were published between 2002 and 2016. They included 0 to 23 studies (median = 9) and analyzed 0 to 4696 participants (median = 666). Seven reliable reviews (64%) assessed surgical interventions. Most systematic reviews of interventions for

  5. The uncorrected refractive error challenge

    Directory of Open Access Journals (Sweden)

    Kovin Naidoo

    2016-11-01

    Full Text Available Refractive error affects people of all ages, socio-economic status and ethnic groups. The most recent statistics estimate that, worldwide, 32.4 million people are blind and 191 million people have vision impairment. Vision impairment has been defined based on distance visual acuity only, and uncorrected distance refractive error (mainly myopia is the single biggest cause of worldwide vision impairment. However, when we also consider near visual impairment, it is clear that even more people are affected. From research it was estimated that the number of people with vision impairment due to uncorrected distance refractive error was 107.8 million,1 and the number of people affected by uncorrected near refractive error was 517 million, giving a total of 624.8 million people.

  6. Crystalline lens power and refractive error.

    Science.gov (United States)

    Iribarren, Rafael; Morgan, Ian G; Nangia, Vinay; Jonas, Jost B

    2012-02-01

    To study the relationships between the refractive power of the crystalline lens, overall refractive error of the eye, and degree of nuclear cataract. All phakic participants of the population-based Central India Eye and Medical Study with an age of 50+ years were included. Calculation of the refractive lens power was based on distance noncycloplegic refractive error, corneal refractive power, anterior chamber depth, lens thickness, and axial length according to Bennett's formula. The study included 1885 subjects. Mean refractive lens power was 25.5 ± 3.0 D (range, 13.9-36.6). After adjustment for age and sex, the standardized correlation coefficients (β) of the association with the ocular refractive error were highest for crystalline lens power (β = -0.41; P lens opacity grade (β = -0.42; P lens power (β = -0.95), lower corneal refractive power (β = -0.76), higher lens thickness (β = 0.30), deeper anterior chamber (β = 0.28), and less marked nuclear lens opacity (β = -0.05). Lens thickness was significantly lower in eyes with greater nuclear opacity. Variations in refractive error in adults aged 50+ years were mostly influenced by variations in axial length and in crystalline lens refractive power, followed by variations in corneal refractive power, and, to a minor degree, by variations in lens thickness and anterior chamber depth.

  7. Correction of refractive errors

    Directory of Open Access Journals (Sweden)

    Vladimir Pfeifer

    2005-10-01

    Full Text Available Background: Spectacles and contact lenses are the most frequently used, the safest and the cheapest way to correct refractive errors. The development of keratorefractive surgery has brought new opportunities for correction of refractive errors in patients who have the need to be less dependent of spectacles or contact lenses. Until recently, RK was the most commonly performed refractive procedure for nearsighted patients.Conclusions: The introduction of excimer laser in refractive surgery has given the new opportunities of remodelling the cornea. The laser energy can be delivered on the stromal surface like in PRK or deeper on the corneal stroma by means of lamellar surgery. In LASIK flap is created with microkeratome in LASEK with ethanol and in epi-LASIK the ultra thin flap is created mechanically.

  8. Effect of refractive error on temperament and character properties

    Institute of Scientific and Technical Information of China (English)

    Emine; Kalkan; Akcay; Fatih; Canan; Huseyin; Simavli; Derya; Dal; Hacer; Yalniz; Nagihan; Ugurlu; Omer; Gecici; Nurullah; Cagil

    2015-01-01

    AIM: To determine the effect of refractive error on temperament and character properties using Cloninger’s psychobiological model of personality.METHODS: Using the Temperament and Character Inventory(TCI), the temperament and character profiles of 41 participants with refractive errors(17 with myopia,12 with hyperopia, and 12 with myopic astigmatism) were compared to those of 30 healthy control participants.Here, temperament comprised the traits of novelty seeking, harm-avoidance, and reward dependence, while character comprised traits of self-directedness,cooperativeness, and self-transcendence.RESULTS: Participants with refractive error showed significantly lower scores on purposefulness,cooperativeness, empathy, helpfulness, and compassion(P <0.05, P <0.01, P <0.05, P <0.05, and P <0.01,respectively).CONCLUSION: Refractive error might have a negative influence on some character traits, and different types of refractive error might have different temperament and character properties. These personality traits may be implicated in the onset and/or perpetuation of refractive errors and may be a productive focus for psychotherapy.

  9. Emmetropisation and the aetiology of refractive errors

    Science.gov (United States)

    Flitcroft, D I

    2014-01-01

    The distribution of human refractive errors displays features that are not commonly seen in other biological variables. Compared with the more typical Gaussian distribution, adult refraction within a population typically has a negative skew and increased kurtosis (ie is leptokurtotic). This distribution arises from two apparently conflicting tendencies, first, the existence of a mechanism to control eye growth during infancy so as to bring refraction towards emmetropia/low hyperopia (ie emmetropisation) and second, the tendency of many human populations to develop myopia during later childhood and into adulthood. The distribution of refraction therefore changes significantly with age. Analysis of the processes involved in shaping refractive development allows for the creation of a life course model of refractive development. Monte Carlo simulations based on such a model can recreate the variation of refractive distributions seen from birth to adulthood and the impact of increasing myopia prevalence on refractive error distributions in Asia. PMID:24406411

  10. Refractive Errors Affect the Vividness of Visual Mental Images

    Science.gov (United States)

    Palermo, Liana; Nori, Raffaella; Piccardi, Laura; Zeri, Fabrizio; Babino, Antonio; Giusberti, Fiorella; Guariglia, Cecilia

    2013-01-01

    The hypothesis that visual perception and mental imagery are equivalent has never been explored in individuals with vision defects not preventing the visual perception of the world, such as refractive errors. Refractive error (i.e., myopia, hyperopia or astigmatism) is a condition where the refracting system of the eye fails to focus objects sharply on the retina. As a consequence refractive errors cause blurred vision. We subdivided 84 individuals according to their spherical equivalent refraction into Emmetropes (control individuals without refractive errors) and Ametropes (individuals with refractive errors). Participants performed a vividness task and completed a questionnaire that explored their cognitive style of thinking before their vision was checked by an ophthalmologist. Although results showed that Ametropes had less vivid mental images than Emmetropes this did not affect the development of their cognitive style of thinking; in fact, Ametropes were able to use both verbal and visual strategies to acquire and retrieve information. Present data are consistent with the hypothesis of equivalence between imagery and perception. PMID:23755186

  11. [Incidence of refractive errors with corrective aids subsequent selection].

    Science.gov (United States)

    Benes, P; Synek, S; Petrová, S; Sokolová, Sidlová J; Forýtková, L; Holoubková, Z

    2012-02-01

    age was 43 +/- 18,73 years. Objective refraction - sphere: +0,32 +/- 0,45 D; cylinder: -0,51 +/- 0,28 D, axis of: 94,7 degrees +/- 57,5 degrees. Values of objective refraction take higher values than the subsequent execution of the subjective examination of the refractive error and recommendation of the appropriate type of corrective aids. This all is in examined groups and in the individual components of refractive errors. It also confirmed the hypothesis that the population outweighs with-the-rule astigmatism, the deployment of resources according to the literature ranges from 90 degrees +/- 10 degrees. The values observed correction of refractive errors are then derived also offer the most common prescription ranges and products for the correction of given ametropia. In the selection and design corrective aids, we are often limited. Our task is then to manufacture high quality, functional and aesthetic corrective aids, you need to connect knowledge from the fields of optics, optometry and ophthalmology. Faster visual rehabilitation simplifies clients' rapid return to everyday life.

  12. refractive errors among secondary school students in Isuikwuato

    African Journals Online (AJOL)

    Eyamba

    STUDENTS IN ISUIKWUATO LOCAL GOVERNMENT AREA OF ... the prevalence and types of refractive errors among secondary school students ... KEYWORDS: Refractive error, Secondary School students, ametropia, .... interviews of the teachers as regards the general performance of those students with obvious visual.

  13. Optical products for refractive error and low vision

    Directory of Open Access Journals (Sweden)

    Kovin S Naidoo

    2011-12-01

    Full Text Available This article will focus on the optical products required for the efficient delivery of refractive error and low vision services, and provide insight into how they can be managed effectively to ensure a quality service. You can consult the IAPB Standard List (see page 30 for suggestions regarding the optical products you may require at your facility as well as recommended suppliers.

  14. Refractive error magnitude and variability: Relation to age.

    Science.gov (United States)

    Irving, Elizabeth L; Machan, Carolyn M; Lam, Sharon; Hrynchak, Patricia K; Lillakas, Linda

    2018-03-19

    To investigate mean ocular refraction (MOR) and astigmatism, over the human age range and compare severity of refractive error to earlier studies from clinical populations having large age ranges. For this descriptive study patient age, refractive error and history of surgery affecting refraction were abstracted from the Waterloo Eye Study database (WatES). Average MOR, standard deviation of MOR and astigmatism were assessed in relation to age. Refractive distributions for developmental age groups were determined. MOR standard deviation relative to average MOR was evaluated. Data from earlier clinically based studies with similar age ranges were compared to WatES. Right eye refractive errors were available for 5933 patients with no history of surgery affecting refraction. Average MOR varied with age. Children <1 yr of age were the most hyperopic (+1.79D) and the highest magnitude of myopia was found at 27yrs (-2.86D). MOR distributions were leptokurtic, and negatively skewed. The mode varied with age group. MOR variability increased with increasing myopia. Average astigmatism increased gradually to age 60 after which it increased at a faster rate. By 85+ years it was 1.25D. J 0 power vector became increasingly negative with age. J 45 power vector values remained close to zero but variability increased at approximately 70 years. In relation to comparable earlier studies, WatES data were most myopic. Mean ocular refraction and refractive error distribution vary with age. The highest magnitude of myopia is found in young adults. Similar to prevalence, the severity of myopia also appears to have increased since 1931. Copyright © 2018 Spanish General Council of Optometry. Published by Elsevier España, S.L.U. All rights reserved.

  15. Prevalence of Refractive Error in Singaporean Chinese Children: The Strabismus, Amblyopia, and Refractive Error in Young Singaporean Children (STARS) Study

    OpenAIRE

    Dirani, Mohamed; Chan, Yiong-Huak; Gazzard, Gus; Hornbeak, Dana Marie; Leo, Seo-Wei; Selvaraj, Prabakaran; Zhou, Brendan; Young, Terri L.; Mitchell, Paul; Varma, Rohit; Wong, Tien Yin; Saw, Seang-Mei

    2010-01-01

    Using population-based data, the authors report, for the first time, the prevalence of refractive error in Singaporean Chinese children aged 6 to 72 months. In selected regions of Singapore, myopia has been shown to affect more than 80% of adults; therefore, this paper provides insights into the development of refractive error at a very young age.

  16. Prevalence of Refractive errors among Primary School Pupils in ...

    African Journals Online (AJOL)

    Administrator

    Effective management of blindness due to refractive errors is readily available in developed countries. 1 ... Key words: Refractive errors, Children, Prevalence, Kenya. 165 .... financial support towards the funding of this study. REFERENCES. 1.

  17. Refractive Errors in State Junior High School Students in Bandung

    Directory of Open Access Journals (Sweden)

    Sabila Tasyakur Nikmah

    2016-12-01

    Full Text Available Background: Uncorrected refractive error is one of the avoidable causes of vision impairment in children and adults. Vision problem in children has been shown to affect their psychological and academic performance. This study aims at identifying and gaining more insights on the characteristic of the refractive errors in state junior high school students in Bandung to avoid uncorrected refractive errors. Methods: A cross-sectional study was conducted in September–November 2015 in state junior high schools in Bandung, West Java, Indonesia. Sample was selected using multistage random sampling technique. Children were examined using tumbling E examination; then students with visual acuity worse than 6/12 underwent Snellen Chart test, refractometry without pupil dilatation, correction with trial lens, then was followed by direct ophthalmoscopy. Results: From a total of 435 children who completed all the examination, 80 children (18.39% had refractive errors; consisted of 151 eyes (94.38% with myopia and 9 eyes (5.62% with astigmatism. Refractive errors were found to be more common in female children (73.7% than male children (26.3%. Among those with refractive errors, 45 children (56.3% did not use any corrective glasses before the examination. Conclusions: Routine refractive error test in vision screening examination is needed for students. It is equally important to raise more awareness toward eye disease in community.

  18. Refractive errors in children and adolescents in Bucaramanga (Colombia).

    Science.gov (United States)

    Galvis, Virgilio; Tello, Alejandro; Otero, Johanna; Serrano, Andrés A; Gómez, Luz María; Castellanos, Yuly

    2017-01-01

    The aim of this study was to establish the frequency of refractive errors in children and adolescents aged between 8 and 17 years old, living in the metropolitan area of Bucaramanga (Colombia). This study was a secondary analysis of two descriptive cross-sectional studies that applied sociodemographic surveys and assessed visual acuity and refraction. Ametropias were classified as myopic errors, hyperopic errors, and mixed astigmatism. Eyes were considered emmetropic if none of these classifications were made. The data were collated using free software and analyzed with STATA/IC 11.2. One thousand two hundred twenty-eight individuals were included in this study. Girls showed a higher rate of ametropia than boys. Hyperopic refractive errors were present in 23.1% of the subjects, and myopic errors in 11.2%. Only 0.2% of the eyes had high myopia (≤-6.00 D). Mixed astigmatism and anisometropia were uncommon, and myopia frequency increased with age. There were statistically significant steeper keratometric readings in myopic compared to hyperopic eyes. The frequency of refractive errors that we found of 36.7% is moderate compared to the global data. The rates and parameters statistically differed by sex and age groups. Our findings are useful for establishing refractive error rate benchmarks in low-middle-income countries and as a baseline for following their variation by sociodemographic factors.

  19. Refractive errors in children and adolescents in Bucaramanga (Colombia

    Directory of Open Access Journals (Sweden)

    Virgilio Galvis

    Full Text Available ABSTRACT Purpose: The aim of this study was to establish the frequency of refractive errors in children and adolescents aged between 8 and 17 years old, living in the metropolitan area of Bucaramanga (Colombia. Methods: This study was a secondary analysis of two descriptive cross-sectional studies that applied sociodemographic surveys and assessed visual acuity and refraction. Ametropias were classified as myopic errors, hyperopic errors, and mixed astigmatism. Eyes were considered emmetropic if none of these classifications were made. The data were collated using free software and analyzed with STATA/IC 11.2. Results: One thousand two hundred twenty-eight individuals were included in this study. Girls showed a higher rate of ametropia than boys. Hyperopic refractive errors were present in 23.1% of the subjects, and myopic errors in 11.2%. Only 0.2% of the eyes had high myopia (≤-6.00 D. Mixed astigmatism and anisometropia were uncommon, and myopia frequency increased with age. There were statistically significant steeper keratometric readings in myopic compared to hyperopic eyes. Conclusions: The frequency of refractive errors that we found of 36.7% is moderate compared to the global data. The rates and parameters statistically differed by sex and age groups. Our findings are useful for establishing refractive error rate benchmarks in low-middle-income countries and as a baseline for following their variation by sociodemographic factors.

  20. REFRACTIVE ERROR STATUS IN BAYELSA STATE, NIGERIA

    African Journals Online (AJOL)

    LIVINGSTON

    deepening poverty because of their inability to see well” . In 2002, the .... all the refractions) and other health workers. During the period .... To the best of our knowledge, there is no ... 2020 and eliminate uncorrected refractive error within the ...

  1. Preliminary study of the correlation between refractive error and corneal refractive power, corneal asphericity in myopic eye

    Directory of Open Access Journals (Sweden)

    Qi-Chao Han

    2014-05-01

    Full Text Available AIM: To investigate the correlation between myopic refractive error and relative factors, including the corneal refractive power, posterior refractive power, axial length, corneal asphericity coefficient Q value, central cornea thickness(CCTand intraocular pressure(IOP. METHODS:According to the degree of myopia measured by subjective refraction, 138 myopia patients were divided into three subgroups: mild group(-1.00D--3.00D, moderate group(-3.25D--6.00D, high group(>6.00D. The Pentacam anterior segment tomographer(Germany, Oculus Companywas used to measure the corneal refractive power, posterior refractive power, and corneal asphericity in the right eye. IOP, CCT and axial length were measured by a non-contact tonometer and A-scan ultrasonic, respectively. The data was analyzed with a Pearson correlation analysis and one-way ANOVA. RESULTS: The myopic refractive error was negatively correlated with the axial length(r=-0.682, Pr=0.009, P=0.925. The axial length was negatively correlated with corneal refractive power(r=-0.554, Pr=0.674, Pr=-0.375, P=0.01. There was no significantly correlation between the myopic refractive error and CCT, IOP(r=-0.138, P=0.141; r=-0.121, P=0.157. CONCLUSION:The corneal refractive power plays the role of emmetropization during the development of myopia. There is clinic significance for the correlation between Q value and refractive error, IOP to guide the corneal refractive surgery.

  2. Prevalence of Refractive Error and Visual Impairment among Rural ...

    African Journals Online (AJOL)

    GB

    prevalence of refractive error was 3.5% (myopia 2.6% and hyperopia 0.9%). Refractive error ... 2Department of Ophthalmology, Addis Ababa University Medical Faculty, Ethiopia. Corresponding ... the main cause of low vision and the second cause of blindness .... the visual loss. All data were entered into computers using.

  3. Prevalence of Refractive Error and Visual Impairment among Rural ...

    African Journals Online (AJOL)

    Refractive error was the major cause of visual impairment accounting for 54% of all causes in the study group. No child was found wearing ... So, large scale community level screening for refractive error should be conducted and integrated with regular school eye screening programs. Effective strategies need to be devised ...

  4. Refractive error in school children in Agona Swedru, Ghana

    Directory of Open Access Journals (Sweden)

    G. O. Ovenseri-Ogbomo

    2010-12-01

    Full Text Available Uncorrected refractive errors remains a public health problem among different population groups. Among schoolchildren, uncorrected refractive errors have a considerable impact on learning andacademic achievement especially in underserved and under-resourced communities. A school based cross-sectional study was carriedout to estimate the prevalence and distribution of refractive error among schoolchildren in the Agona Swedru municipality of Central Region of Ghana. 637 schoolchildren aged 11-18 years old were randomly selected for the study. Non-cycloplegic refraction was performed on each child who failed the reading test. Hyperopia was defined as spherical power of ≥ + 0.75 D, myopia as ≤ – 0.50 D and astigmatism as a cylindrical power of ≤ – 0.50 D. Of the children examined, only 13.3% had previously had an eye examination.Visual impairment (VA of 6/12 or worse in the better eye was present in 4.5% of the children examined. Of those who failed the reading test, 85.9% had refractive error. The prevalence of hyperopia, myopia and astigmatism was 5.0%, 1.7% and 6.6% respectively. The study concludes that uncorrected refractive error is a common cause of visual impairment among schoolchildren in the municipality. A low uptake of eye care is also noted in the study. The study therefore recommends that the education authority in collaboration with the District Health Directorate institute appropriate measures to ensure compulsory eye examination for schoolchildren in the Agona Swedru district. (S Afr Optom 2010 69(2 86-92

  5. Automatic diagnostic system for measuring ocular refractive errors

    Science.gov (United States)

    Ventura, Liliane; Chiaradia, Caio; de Sousa, Sidney J. F.; de Castro, Jarbas C.

    1996-05-01

    Ocular refractive errors (myopia, hyperopia and astigmatism) are automatic and objectively determined by projecting a light target onto the retina using an infra-red (850 nm) diode laser. The light vergence which emerges from the eye (light scattered from the retina) is evaluated in order to determine the corresponding ametropia. The system basically consists of projecting a target (ring) onto the retina and analyzing the scattered light with a CCD camera. The light scattered by the eye is divided into six portions (3 meridians) by using a mask and a set of six prisms. The distance between the two images provided by each of the meridians, leads to the refractive error of the referred meridian. Hence, it is possible to determine the refractive error at three different meridians, which gives the exact solution for the eye's refractive error (spherical and cylindrical components and the axis of the astigmatism). The computational basis used for the image analysis is a heuristic search, which provides satisfactory calculation times for our purposes. The peculiar shape of the target, a ring, provides a wider range of measurement and also saves parts of the retina from unnecessary laser irradiation. Measurements were done in artificial and in vivo eyes (using cicloplegics) and the results were in good agreement with the retinoscopic measurements.

  6. Refractive errors among children, adolescents and adults attending eye clinics in Mexico

    Directory of Open Access Journals (Sweden)

    Francisco Gomez-Salazar

    2017-05-01

    Full Text Available AIM: To assess the proportion of refractive errors in the Mexican population that visited primary care optometry clinics in fourteen states of Mexico. METHODS: Refractive data from 676 856 patients aged 6 to 90y were collected from optometry clinics in fourteen states of Mexico between 2014 and 2015. The refractive errors were classified by the spherical equivalent (SE, as follows: sphere+½ cylinder. Myopia (SE>-0.50 D, hyperopia (SE>+0.50 D, emmetropia (-0.50≤SE≤+0.50, and astigmatism alone (cylinder≥-0.25 D. A negative cylinder was selected as a notation. RESULTS: The proportion (95% confidence interval among all of the subjects was hyperopia 21.0% (20.9-21.0, emmetropia 40.7% (40.5-40.8, myopia 24.8% (24.7-24.9 and astigmatism alone 13.5% (13.4-13.5. Myopia was the most common refractive error and frequency seemed to increase among the young population (10 to 29 years old, however, hyperopia increased among the aging population (40 to 79 years old, and astigmatism alone showed a decreasing trend with age (6 to 90y; from 19.7% to 10.8%. There was a relationship between age and all refractive errors (approximately 60%, aged 50 and older. The proportion of any clinically important refractive error was higher in males (61.2% than in females (58.3%; P<0.0001. From fourteen states that collected information, the proportion of refractive error showed variability in different geographical areas of Mexico. CONCLUSION: Myopia is the most common refractive error in the population studied. This study provides the first data on refractive error in Mexico. Further programs and studies must be developed to address the refractive errors needs of the Mexican population.

  7. [Nature or nurture: effects of parental ametropia on children's refractive errors].

    Science.gov (United States)

    Landmann, A; Bechrakis, E

    2013-12-01

    The aim of this study was to quantify the degree of association between juvenile refraction errors and parental refraction status. Using a simple questionnaire we conducted a cross-sectional study to determine the prevalence and magnitudes of refractive errors and of parental refraction status in a sample (n=728) of 10- to 18-year-old Austrian grammar school students. Students with myopia or hyperopia were more likely to have ametropic parents and refraction was more myopic in juveniles with one or two parents being ametropic. The prevalence of myopia in children with 2 ametropic parents was 54%, decreasing to 35% in pupils with 1 and to 13% in children with no ametropic parents. The odds ratio for 1 and 2 compared with no ametropic parents was 8.3 and 3.7 for myopia and 1.3 and 1.6 for hyperopia, respectively. Furthermore, the data indicate a stronger influence of the maternal ametropia on children's refractive errors than paternal ametropia. Genetic factors play a significant role in refractive error and may be of dominant influence for school myopia under conditions of low environmental variation.

  8. PREVALENCE OF REFRACTIVE ERRORS AMONG CHILDREN IN RURA L AREAS OF CHITTOOR DISTRICT, A . P

    Directory of Open Access Journals (Sweden)

    Sadana

    2015-08-01

    Full Text Available BACKGROUND: The uncorrected refractive errors are the main cause of low vision which hampers performance at school, reduces productivity and impairs quality of life. It is considered to be one of the most important priorities in the global initiation for the elimination of avoidable blindness. The refractive errors are especially common among children as they do not complain and adjust with circumstances. School children constitute an ideal group for study of refractive errors because most of them go to school, easily accessible and offer excellent opportunity for services and health education. MATERIAL & METHODS: This is a cross sectional study conducted among 2,568 children attending various government schools in the rural areas of Chittoor district. The study was carried out during January to June 2015. A preliminary examination of visual acuity was determined by Snellen’s chart and those with defective vision were subjected to detailed eye examination by a specialist. The results were analyzed using MS excel software and Epiinfo 7 software version using percentages and Chi - square test. RESULTS: The overall prevalence of refractive errors among children was found to be 11.3%. (Astigmatism - 5.8%; myopia - 4.2%; hypermetropia - 1.4%. The prevalence of refractive errors increased steadily from 5.7% in 5 - 7 years age group to 14.7% in 14 - 16 years group. The prevalence was found to be similar in male and female children. The prevalence of myopia and astigmatism was found to increase steadily with age while hypermetropia showed an inverse trend CONCLUSIONS: Examination of school children for refractive errors is a useful strategy for early diagnosis and intervention.

  9. The Determinants of Early Refractive Error on School-Going Chinese Children

    Directory of Open Access Journals (Sweden)

    K. Jayaraman

    2016-04-01

    Full Text Available Refractive error is a common social issue in every walks of human life, and its prevalence recorded the highest among Chinese population, particularly among people living in southern China, Hong Kong, Thailand, Singapore, and Malaysia. Refractive error is the simplest disorder to treat and supposed to cost the effective health care intervention. The present study included 168 Chinese school-going children aged 10 to 12 years; they were selected from different schools of urban Malaysia. It was surprising to see that 112 (66.7% children had the early onset of refractive error; refractive error was also detected late among the primary school or secondary school students. The findings revealed that the determinants of refractive error among Chinese children were personal achievements and machine dependence. The possible reasons for the above significant factors emerged could be attributed to the inbuilt culture and traditions of Chinese parents who insist that their children should be hardworking and focus on school subjects so that their parents allow them to use luxury electronic devices.

  10. Prevalence of refractive errors among junior high school students in ...

    African Journals Online (AJOL)

    Among school children, uncorrected refractive errors have a considerable impact on their participation and learning in class. The aim of this study was to assess the prevalence of refractive error among students in the Ejisu-Juabeng Municipality of Ghana. A survey with multi-stage sampling was undertaken. We interviewed ...

  11. Corrective Techniques and Future Directions for Treatment of Residual Refractive Error Following Cataract Surgery

    Science.gov (United States)

    Moshirfar, Majid; McCaughey, Michael V; Santiago-Caban, Luis

    2015-01-01

    Postoperative residual refractive error following cataract surgery is not an uncommon occurrence for a large proportion of modern-day patients. Residual refractive errors can be broadly classified into 3 main categories: myopic, hyperopic, and astigmatic. The degree to which a residual refractive error adversely affects a patient is dependent on the magnitude of the error, as well as the specific type of intraocular lens the patient possesses. There are a variety of strategies for resolving residual refractive errors that must be individualized for each specific patient scenario. In this review, the authors discuss contemporary methods for rectification of residual refractive error, along with their respective indications/contraindications, and efficacies. PMID:25663845

  12. Three-dimensional ray-tracing model for the study of advanced refractive errors in keratoconus.

    Science.gov (United States)

    Schedin, Staffan; Hallberg, Per; Behndig, Anders

    2016-01-20

    We propose a numerical three-dimensional (3D) ray-tracing model for the analysis of advanced corneal refractive errors. The 3D modeling was based on measured corneal elevation data by means of Scheimpflug photography. A mathematical description of the measured corneal surfaces from a keratoconus (KC) patient was used for the 3D ray tracing, based on Snell's law of refraction. A model of a commercial intraocular lens (IOL) was included in the analysis. By modifying the posterior IOL surface, it was shown that the imaging quality could be significantly improved. The RMS values were reduced by approximately 50% close to the retina, both for on- and off-axis geometries. The 3D ray-tracing model can constitute a basis for simulation of customized IOLs that are able to correct the advanced, irregular refractive errors in KC.

  13. Nature of the Refractive Errors in Rhesus Monkeys (Macaca mulatta) with Experimentally Induced Ametropias

    Science.gov (United States)

    Qiao-Grider, Ying; Hung, Li-Fang; Kee, Chea-su; Ramamirtham, Ramkumar; Smith, Earl L.

    2010-01-01

    We analyzed the contribution of individual ocular components to vision-induced ametropias in 210 rhesus monkeys. The primary contribution to refractive-error development came from vitreous chamber depth; a minor contribution from corneal power was also detected. However, there was no systematic relationship between refractive error and anterior chamber depth or between refractive error and any crystalline lens parameter. Our results are in good agreement with previous studies in humans, suggesting that the refractive errors commonly observed in humans are created by vision-dependent mechanisms that are similar to those operating in monkeys. This concordance emphasizes the applicability of rhesus monkeys in refractive-error studies. PMID:20600237

  14. Prevalence of refraction errors and color blindness in heavy vehicle drivers.

    Science.gov (United States)

    Erdoğan, Haydar; Ozdemir, Levent; Arslan, Seher; Cetin, Ilhan; Ozeç, Ayşe Vural; Cetinkaya, Selma; Sümer, Haldun

    2011-01-01

    To investigate the frequency of eye disorders in heavy vehicle drivers. A cross-sectional type study was conducted between November 2004 and September 2006 in 200 driver and 200 non-driver persons. A complete ophthalmologic examination was performed, including visual acuity, and dilated examination of the posterior segment. We used the auto refractometer for determining refractive errors. According to eye examination results, the prevalence of the refractive error was 21.5% and 31.3% in study and control groups respectively (P<0.05). The most common type of refraction error in the study group was myopic astigmatism (8.3%) while in the control group simple myopia (12.8%). Prevalence of dyschromatopsia in the rivers, control group and total group was 2.2%, 2.8% and 2.6% respectively. A considerably high number of drivers are in lack of optimal visual acuity. Refraction errors in drivers may impair the traffic security.

  15. Correction of refractive errors in rhesus macaques (Macaca mulatta) involved in visual research.

    Science.gov (United States)

    Mitchell, Jude F; Boisvert, Chantal J; Reuter, Jon D; Reynolds, John H; Leblanc, Mathias

    2014-08-01

    Macaques are the most common animal model for studies in vision research, and due to their high value as research subjects, often continue to participate in studies well into old age. As is true in humans, visual acuity in macaques is susceptible to refractive errors. Here we report a case study in which an aged macaque demonstrated clear impairment in visual acuity according to performance on a demanding behavioral task. Refraction demonstrated bilateral myopia that significantly affected behavioral and visual tasks. Using corrective lenses, we were able to restore visual acuity. After correction of myopia, the macaque's performance on behavioral tasks was comparable to that of a healthy control. We screened 20 other male macaques to assess the incidence of refractive errors and ocular pathologies in a larger population. Hyperopia was the most frequent ametropia but was mild in all cases. A second macaque had mild myopia and astigmatism in one eye. There were no other pathologies observed on ocular examination. We developed a simple behavioral task that visual research laboratories could use to test visual acuity in macaques. The test was reliable and easily learned by the animals in 1 d. This case study stresses the importance of screening macaques involved in visual science for refractive errors and ocular pathologies to ensure the quality of research; we also provide simple methodology for screening visual acuity in these animals.

  16. Sources of medical error in refractive surgery.

    Science.gov (United States)

    Moshirfar, Majid; Simpson, Rachel G; Dave, Sonal B; Christiansen, Steven M; Edmonds, Jason N; Culbertson, William W; Pascucci, Stephen E; Sher, Neal A; Cano, David B; Trattler, William B

    2013-05-01

    To evaluate the causes of laser programming errors in refractive surgery and outcomes in these cases. In this multicenter, retrospective chart review, 22 eyes of 18 patients who had incorrect data entered into the refractive laser computer system at the time of treatment were evaluated. Cases were analyzed to uncover the etiology of these errors, patient follow-up treatments, and final outcomes. The results were used to identify potential methods to avoid similar errors in the future. Every patient experienced compromised uncorrected visual acuity requiring additional intervention, and 7 of 22 eyes (32%) lost corrected distance visual acuity (CDVA) of at least one line. Sixteen patients were suitable candidates for additional surgical correction to address these residual visual symptoms and six were not. Thirteen of 22 eyes (59%) received surgical follow-up treatment; nine eyes were treated with contact lenses. After follow-up treatment, six patients (27%) still had a loss of one line or more of CDVA. Three significant sources of error were identified: errors of cylinder conversion, data entry, and patient identification error. Twenty-seven percent of eyes with laser programming errors ultimately lost one or more lines of CDVA. Patients who underwent surgical revision had better outcomes than those who did not. Many of the mistakes identified were likely avoidable had preventive measures been taken, such as strict adherence to patient verification protocol or rigorous rechecking of treatment parameters. Copyright 2013, SLACK Incorporated.

  17. Refractive error assessment: influence of different optical elements and current limits of biometric techniques.

    Science.gov (United States)

    Ribeiro, Filomena; Castanheira-Dinis, Antonio; Dias, Joao Mendanha

    2013-03-01

    To identify and quantify sources of error on refractive assessment using exact ray tracing. The Liou-Brennan eye model was used as a starting point and its parameters were varied individually within a physiological range. The contribution of each parameter to refractive error was assessed using linear regression curve fits and Gaussian error propagation analysis. A MonteCarlo analysis quantified the limits of refractive assessment given by current biometric measurements. Vitreous and aqueous refractive indices are the elements that influence refractive error the most, with a 1% change of each parameter contributing to a refractive error variation of +1.60 and -1.30 diopters (D), respectively. In the phakic eye, axial length measurements taken by ultrasound (vitreous chamber depth, lens thickness, and anterior chamber depth [ACD]) were the most sensitive to biometric errors, with a contribution to the refractive error of 62.7%, 14.2%, and 10.7%, respectively. In the pseudophakic eye, vitreous chamber depth showed the highest contribution at 53.7%, followed by postoperative ACD at 35.7%. When optic measurements were considered, postoperative ACD was the most important contributor, followed by anterior corneal surface and its asphericity. A MonteCarlo simulation showed that current limits of refractive assessment are 0.26 and 0.28 D for the phakic and pseudophakic eye, respectively. The most relevant optical elements either do not have available measurement instruments or the existing instruments still need to improve their accuracy. Ray tracing can be used as an optical assessment technique, and may be the correct path for future personalized refractive assessment. Copyright 2013, SLACK Incorporated.

  18. The refractive index in electron microscopy and the errors of its approximations

    Energy Technology Data Exchange (ETDEWEB)

    Lentzen, M.

    2017-05-15

    In numerical calculations for electron diffraction often a simplified form of the electron-optical refractive index, linear in the electric potential, is used. In recent years improved calculation schemes have been proposed, aiming at higher accuracy by including higher-order terms of the electric potential. These schemes start from the relativistically corrected Schrödinger equation, and use a second simplified form, now for the refractive index squared, being linear in the electric potential. The second and higher-order corrections thus determined have, however, a large error, compared to those derived from the relativistically correct refractive index. The impact of the two simplifications on electron diffraction calculations is assessed through numerical comparison of the refractive index at high-angle Coulomb scattering and of cross-sections for a wide range of scattering angles, kinetic energies, and atomic numbers. - Highlights: • The standard model for the refractive index in electron microscopy is investigated. • The error of the standard model is proportional to the electric potential squared. • Relativistically correct error terms are derived from the energy-momentum relation. • The errors are assessed for Coulomb scattering varying energy and atomic number. • Errors of scattering cross-sections are pronounced at large angles and attain 10%.

  19. The refractive index in electron microscopy and the errors of its approximations

    International Nuclear Information System (INIS)

    Lentzen, M.

    2017-01-01

    In numerical calculations for electron diffraction often a simplified form of the electron-optical refractive index, linear in the electric potential, is used. In recent years improved calculation schemes have been proposed, aiming at higher accuracy by including higher-order terms of the electric potential. These schemes start from the relativistically corrected Schrödinger equation, and use a second simplified form, now for the refractive index squared, being linear in the electric potential. The second and higher-order corrections thus determined have, however, a large error, compared to those derived from the relativistically correct refractive index. The impact of the two simplifications on electron diffraction calculations is assessed through numerical comparison of the refractive index at high-angle Coulomb scattering and of cross-sections for a wide range of scattering angles, kinetic energies, and atomic numbers. - Highlights: • The standard model for the refractive index in electron microscopy is investigated. • The error of the standard model is proportional to the electric potential squared. • Relativistically correct error terms are derived from the energy-momentum relation. • The errors are assessed for Coulomb scattering varying energy and atomic number. • Errors of scattering cross-sections are pronounced at large angles and attain 10%.

  20. MANAGEMENT OF RESIDUAL REFRACTIVE ERROR AFTER CATARACT PHACOEMULSIFICATION. PART 2. INTRAOCULAR APPROACHES

    Directory of Open Access Journals (Sweden)

    K. B. Pershin

    2017-01-01

    Full Text Available The review presents an  analysis  of the  literature  data  on  the  methods of surgical  correction of residual  refractive  error after cataract phacoemulsification. Keratorefractive and intraocular approaches are  considered in details.  A comparison of the  efficacy and  safet y  of different groups   of methods on  the  example  of comparative studies is given.  Historically earlier  keratorefractive methods (laser  vision correction with LASIK and  PRK techniques on intact  eyes,  LASIK after  implantation  of multifocal  IOLs and arcuate keratotomy  after  phaco  are  indicated  for  the  correction of astigmatic refractive  error and  a small  spherical refractive error. Intraocular methods, including the  replacement of the  IOL  and  «piggyback» IOLs implantation  are  used  to  correct a large spherical refractive error. The introduction  of new  technology, the  implantation  of light-adjustable  IOLs, will  expand  the  existing evidence  and provide greater predictabilit y and efficiency of the  method  of correction of residual  refractive error.

  1. Falls and Postural Control in Older Adults With Eye Refractive Errors

    Directory of Open Access Journals (Sweden)

    Afsun Nodehi-Moghadam

    2016-04-01

    Conclusion: Vision impairment of older adults due to refractive error is not associated with an increase in falls. Furthermore, TUG test results did not show balance disorders in these groups. Further research, such as assessment of postural control with advanced devices and considering other falling risk factors is also needed to identify the predictors of falls in older adults with eye refractive errors.

  2. Analysis of refractive error in visual impairment among residents aged 40 years and above in Dongguan City

    Directory of Open Access Journals (Sweden)

    Shu-Hui Chen

    2015-06-01

    Full Text Available AIM: To investigate the prevalence rate of visual impairment caused by refractive error among residents aged 40 years and above, and the influence factors of vision correction. METHODS: We conducted an epidemiological survey of diabetes and diabetic retinopathy among residents aged 40 and above in Guangdong Province, Hengli Town, Dongguan City from 2011 to 2012. At the same time, according to World Health Organization(WHO, according to the daily life vision, 0.05≤visual ability RESULTS: The prevalence rate of visual impairment was 7.90%(707/8 952. The prevalence rate of visual impairment caused by refractive error was 5.57%(499/8 952, accounted for visual impairment of 70.58%(499/707. The prevalence rate of correction of refractive error among visual impairment was 5.36%(480/8 952, accounting for visual impairment of 67.89%(480/707. The prevalence rate of visual impairment uncorrected was 0.21%(19/8 952, accounting for visual impairment of 2.69%(19/707. By χ2 test, with the increase of age, the rate of visual impairment caused by refractive error was significantly decreased(PPP>0.05. The rate of visual impairment can be corrected decreases with age, from 92.1% to 49.1%, there was a statistically significant difference(PPP>0.05. CONCLUSION: Through the development of refractive error correction of positive, can make the daily life of visual impairment in about 2/3 of patients improve eyesight and improve the quality of life of residents.

  3. Refractive error and visual impairment in private school children in Ghana.

    Science.gov (United States)

    Kumah, Ben D; Ebri, Anne; Abdul-Kabir, Mohammed; Ahmed, Abdul-Sadik; Koomson, Nana Ya; Aikins, Samual; Aikins, Amos; Amedo, Angela; Lartey, Seth; Naidoo, Kovin

    2013-12-01

    To assess the prevalence of refractive error and visual impairment in private school children in Ghana. A random selection of geographically defined classes in clusters was used to identify a sample of school children aged 12 to 15 years in the Ashanti Region. Children in 60 clusters were enumerated and examined in classrooms. The examination included visual acuity, retinoscopy, autorefraction under cycloplegia, and examination of anterior segment, media, and fundus. For quality assurance, a random sample of children with reduced and normal vision were selected and re-examined independently. A total of 2454 children attending 53 private schools were enumerated, and of these, 2435 (99.2%) were examined. Prevalence of uncorrected, presenting, and best visual acuity of 20/40 or worse in the better eye was 3.7, 3.5, and 0.4%, respectively. Refractive error was the cause of reduced vision in 71.7% of 152 eyes, amblyopia in 9.9%, retinal disorders in 5.9%, and corneal opacity in 4.6%. Exterior and anterior segment abnormalities occurred in 43 (1.8%) children. Myopia (at least -0.50 D) in one or both eyes was present in 3.2% of children when measured with retinoscopy and in 3.4% measured with autorefraction. Myopia was not significantly associated with gender (P = 0.82). Hyperopia (+2.00 D or more) in at least one eye was present in 0.3% of children with retinoscopy and autorefraction. The prevalence of reduced vision in Ghanaian private school children due to uncorrected refractive error was low. However, the prevalence of amblyopia, retinal disorders, and corneal opacities indicate the need for early interventions.

  4. Prevalence of refractive errors in the European adult population: the Gutenberg Health Study (GHS).

    Science.gov (United States)

    Wolfram, Christian; Höhn, René; Kottler, Ulrike; Wild, Philipp; Blettner, Maria; Bühren, Jens; Pfeiffer, Norbert; Mirshahi, Alireza

    2014-07-01

    To study the distribution of refractive errors among adults of European descent. Population-based eye study in Germany with 15010 participants aged 35-74 years. The study participants underwent a detailed ophthalmic examination according to a standardised protocol. Refractive error was determined by an automatic refraction device (Humphrey HARK 599) without cycloplegia. Definitions for the analysis were myopia +0.5 D, astigmatism >0.5 cylinder D and anisometropia >1.0 D difference in the spherical equivalent between the eyes. Exclusion criterion was previous cataract or refractive surgery. 13959 subjects were eligible. Refractive errors ranged from -21.5 to +13.88 D. Myopia was present in 35.1% of this study sample, hyperopia in 31.8%, astigmatism in 32.3% and anisometropia in 13.5%. The prevalence of myopia decreased, while the prevalence of hyperopia, astigmatism and anisometropia increased with age. 3.5% of the study sample had no refractive correction for their ametropia. Refractive errors affect the majority of the population. The Gutenberg Health Study sample contains more myopes than other study cohorts in adult populations. Our findings do not support the hypothesis of a generally lower prevalence of myopia among adults in Europe as compared with East Asia.

  5. Heritability and familial aggregation of refractive error in the Old Order Amish.

    Science.gov (United States)

    Peet, Jon A; Cotch, Mary-Frances; Wojciechowski, Robert; Bailey-Wilson, Joan E; Stambolian, Dwight

    2007-09-01

    To determine the heritability of refractive error and familial aggregation of myopia and hyperopia in an elderly Old Order Amish (OOA) population. Nine hundred sixty-seven siblings (mean age, 64.2 years) in 269 families were recruited for the Amish Eye Study in the Lancaster County area of Pennsylvania. Refractive error was determined by noncycloplegic manifest refraction. Heritability of refractive error was estimated with multivariate linear regression as twice the residual sibling-sibling correlation after adjustment for age and gender. Logistic regression models were used to estimate the sibling recurrence odds ratio (OR(s)). Myopia and hyperopia were defined with five different thresholds. The age- and gender-adjusted heritability of refractive error was 70% (95% CI: 48%-92%) in the OOA. Age and gender-adjusted OR(s) and sibling recurrence risk (lambda(s)), with different thresholds defining myopia ranged from 3.03 (95% CI: 1.58-5.80) to 7.02 (95% CI: 3.41-14.46) and from 2.36 (95% CI: 1.65-3.19) to 5.61 (95% CI: 3.06-9.34). Age and gender-adjusted OR(s) and lambda(s) for different thresholds of hyperopia ranged from 2.31 (95% CI: 1.56-3.42) to 2.94 (95% CI: 2.04-4.22) and from 1.33 (95% CI: 1.22-1.43) to 1.85 (95% CI: 1.18-2.78), respectively. Women were significantly more likely than men to have hyperopia. There was no significant gender difference in the risk of myopia. In the OOA, refractive error is highly heritable. Hyperopia and myopia aggregate strongly in OOA families.

  6. Prevalence and risk factors of undercorrected refractive errors among Singaporean Malay adults: the Singapore Malay Eye Study.

    Science.gov (United States)

    Rosman, Mohamad; Wong, Tien Y; Tay, Wan-Ting; Tong, Louis; Saw, Seang-Mei

    2009-08-01

    To describe the prevalence and the risk factors of undercorrected refractive error in an adult urban Malay population. This population-based, cross-sectional study was conducted in Singapore in 3280 Malay adults, aged 40 to 80 years. All individuals were examined at a centralized clinic and underwent standardized interviews and assessment of refractive errors and presenting and best corrected visual acuities. Distance presenting visual acuity was monocularly measured by using a logarithm of the minimum angle of resolution (logMAR) number chart at a distance of 4 m, with the participants wearing their "walk-in" optical corrections (spectacles or contact lenses), if any. Refraction was determined by subjective refraction by trained, certified study optometrists. Best corrected visual acuity was monocularly assessed and recorded in logMAR scores using the same test protocol as was used for presenting visual acuity. Undercorrected refractive error was defined as an improvement of at least 0.2 logMAR (2 lines equivalent) in the best corrected visual acuity compared with the presenting visual acuity in the better eye. The mean age of the subjects included in our study was 58 +/- 11 years, and 52% of the subjects were women. The prevalence rate of undercorrected refractive error among Singaporean Malay adults in our study (n = 3115) was 20.4% (age-standardized prevalence rate, 18.3%). More of the women had undercorrected refractive error than the men (21.8% vs. 18.8%, P = 0.04). Undercorrected refractive error was also more common in subjects older than 50 years than in subjects aged 40 to 49 years (22.6% vs. 14.3%, P Malay adults with refractive errors was higher than that of the Singaporean Chinese adults with refractive errors. Undercorrected refractive error is a significant cause of correctable visual impairment among Singaporean Malay adults, affecting one in five persons.

  7. Phakic intraocular lenses for the treatment of refractive errors: an evidence-based analysis.

    Science.gov (United States)

    2009-01-01

    .6 per 10,000 people in Canada have low vision. The 2001 Participation and Activity Limitation Survey (PALS) found that 594,350 (2.5%) Canadians had "difficulty seeing ordinary newsprint or clearly seeing the face of someone from 4 m," and the Canadian National Institute for the Blind (CNIB) registry classified 105,000 (.35%) Canadians as visually disabled. PHAKIC INTRAOCULAR LENSES (PIOL): A phakic intraocular lens (pIOL) is a supplementary lens that is inserted into the anterior or posterior chamber of the eye to correct refractive errors (myopia, hyperopia, and astigmatism). Unlike in cataract surgery, the eye's natural crystalline lens is not removed when the pIOL is inserted, so the eye retains its accommodative ability. In Canada and the United States, iris-fixated (anterior chamber lenses that are anchored to the iris with a claw) and posterior chamber lenses are the only types of pIOLs that are licensed by Health Canada and the Food and Drug Administration, respectively. EVIDENCE-BASED ANALYSIS METHOD: RESEARCH QUESTIONS #ENTITYSTARTX00026; What are the effectiveness, cost-effectiveness, and safety of pIOLs for the treatment of myopia, hyperopia, and astigmatism?Do certain subgroups (e.g. high myopia and low vision) benefit more from pIOLs?How do pIOLs compare with alternative surgical treatment options (LASIK, PRK, and CLE)?Using appropriate keywords, a literature search was conducted up to January 2009. Systematic reviews, meta-analyses, randomized controlled trials, and observational studies with more than 20 eyes receiving pIOLs were eligible for inclusion. The primary outcomes of interest were uncorrected visual acuity (UCVA), predictability of manifest refraction spherical equivalent (MRSE), and adverse events. The GRADE approach was used to systematically and explicitly evaluate the quality of evidence. The search identified 1,131 citations published between January 1, 2003, and January 16, 2009. Including a health technology assessment (HTA) identified in

  8. Prevalence of refractive errors in the Slovak population calculated using the Gullstrand schematic eye model.

    Science.gov (United States)

    Popov, I; Valašková, J; Štefaničková, J; Krásnik, V

    2017-01-01

    A substantial part of the population suffers from some kind of refractive errors. It is envisaged that their prevalence may change with the development of society. The aim of this study is to determine the prevalence of refractive errors using calculations based on the Gullstrand schematic eye model. We used the Gullstrand schematic eye model to calculate refraction retrospectively. Refraction was presented as the need for glasses correction at a vertex distance of 12 mm. The necessary data was obtained using the optical biometer Lenstar LS900. Data which could not be obtained due to the limitations of the device was substituted by theoretical data from the Gullstrand schematic eye model. Only analyses from the right eyes were presented. The data was interpreted using descriptive statistics, Pearson correlation and t-test. The statistical tests were conducted at a level of significance of 5%. Our sample included 1663 patients (665 male, 998 female) within the age range of 19 to 96 years. Average age was 70.8 ± 9.53 years. Average refraction of the eye was 2.73 ± 2.13D (males 2.49 ± 2.34, females 2.90 ± 2.76). The mean absolute error from emmetropia was 3.01 ± 1.58 (males 2.83 ± 2.95, females 3.25 ± 3.35). 89.06% of the sample was hyperopic, 6.61% was myopic and 4.33% emmetropic. We did not find any correlation between refraction and age. Females were more hyperopic than males. We did not find any statistically significant hypermetopic shift of refraction with age. According to our estimation, the calculations of refractive errors using the Gullstrand schematic eye model showed a significant hypermetropic shift of more than +2D. Our results could be used in future for comparing the prevalence of refractive errors using same methods we used.Key words: refractive errors, refraction, Gullstrand schematic eye model, population, emmetropia.

  9. Questionnaires for Measuring Refractive Surgery Outcomes.

    Science.gov (United States)

    Kandel, Himal; Khadka, Jyoti; Lundström, Mats; Goggin, Michael; Pesudovs, Konrad

    2017-06-01

    To identify the questionnaires used to assess refractive surgery outcomes, assess the available questionnaires in regard to their psychometric properties, validity, and reliability, and evaluate the performance of the available questionnaires in measuring refractive surgery outcomes. An extensive literature search was done on PubMed, MEDLINE, Scopus, CINAHL, Cochrane, and Web of Science databases to identify articles that described or used at least one questionnaire to assess refractive surgery outcomes. The information on content quality, validity, reliability, responsiveness, and psychometric properties was extracted and analyzed based on an extensive set of quality criteria. Eighty-one articles describing 27 questionnaires (12 refractive error-specific, including 4 refractive surgery-specific, 7 vision-but-non-refractive, and 8 generic) were included in the review. Most articles (56, 69.1%) described refractive error-specific questionnaires. The Quality of Life Impact of Refractive Correction (QIRC), the Quality of Vision (QoV), and the Near Activity Visual Questionnaire (NAVQ) were originally constructed using Rasch analysis; others were developed using the Classical Test Theory. The National Eye Institute Refractive Quality of Life questionnaire was the most frequently used questionnaire, but it does not provide a valid measurement. The QoV, QIRC, and NAVQ are the three best existing questionnaires to assess visual symptoms, quality of life, and activity limitations, respectively. This review identified three superior quality questionnaires for measuring different aspects of quality of life in refractive surgery. Clinicians and researchers should choose a questionnaire based on the concept being measured with superior psychometric properties. [J Refract Surg. 2017;33(6):416-424.]. Copyright 2017, SLACK Incorporated.

  10. Refractive errors in 3-6 year-old Chinese children: a very low prevalence of myopia?

    Directory of Open Access Journals (Sweden)

    Weizhong Lan

    Full Text Available PURPOSE: To examine the prevalence of refractive errors in children aged 3-6 years in China. METHODS: Children were recruited for a trial of a home-based amblyopia screening kit in Guangzhou preschools, during which cycloplegic refractions were measured in both eyes of 2480 children. Cycloplegic refraction (from 3 to 4 drops of 1% cyclopentolate to ensure abolition of the light reflex was measured by both autorefraction and retinoscopy. Refractive errors were defined as followed: myopia (at least -0.50 D in the worse eye, hyperopia (at least +2.00 D in the worse eye and astigmatism (at least 1.50 D in the worse eye. Different definitions, as specified in the text, were also used to facilitate comparison with other studies. RESULTS: The mean spherical equivalent refractive error was at least +1.22 D for all ages and both genders. The prevalence of myopia for any definition at any age was at most 2.5%, and lower in most cases. In contrast, the prevalence of hyperopia was generally over 20%, and declined slightly with age. The prevalence of astigmatism was between 6% and 11%. There was very little change in refractive error with age over this age range. CONCLUSIONS: Previous reports of less hyperopic mean spherical equivalent refractive error, and more myopia and less hyperopia in children of this age may be due to problems with achieving adequate cycloplegia in children with dark irises. Using up to 4 drops of 1% cyclopentolate may be necessary to accurately measure refractive error in paediatric studies of such children. Our results suggest that children from all ethnic groups may follow a similar pattern of early refractive development, with little myopia and a hyperopic mean spherical equivalent over +1.00 D up to the age of 5-6 years in most conditions.

  11. Risk factors for refractive errors in primary school children (6-12 years old) in Nakhon Pathom Province.

    Science.gov (United States)

    Yingyong, Penpimol

    2010-11-01

    Refractive error is one of the leading causes of visual impairment in children. An analysis of risk factors for refractive error is required to reduce and prevent this common eye disease. To identify the risk factors associated with refractive errors in primary school children (6-12 year old) in Nakhon Pathom province. A population-based cross-sectional analytic study was conducted between October 2008 and September 2009 in Nakhon Pathom. Refractive error, parental refractive status, and hours per week of near activities (studying, reading books, watching television, playing with video games, or working on the computer) were assessed in 377 children who participated in this study. The most common type of refractive error in primary school children was myopia. Myopic children were more likely to have parents with myopia. Children with myopia spend more time at near activities. The multivariate odds ratio (95% confidence interval)for two myopic parents was 6.37 (2.26-17.78) and for each diopter-hour per week of near work was 1.019 (1.005-1.033). Multivariate logistic regression models show no confounding effects between parental myopia and near work suggesting that each factor has an independent association with myopia. Statistical analysis by logistic regression revealed that family history of refractive error and hours of near-work were significantly associated with refractive error in primary school children.

  12. Visual acuity measures do not reliably detect childhood refractive error--an epidemiological study.

    Directory of Open Access Journals (Sweden)

    Lisa O'Donoghue

    Full Text Available PURPOSE: To investigate the utility of uncorrected visual acuity measures in screening for refractive error in white school children aged 6-7-years and 12-13-years. METHODS: The Northern Ireland Childhood Errors of Refraction (NICER study used a stratified random cluster design to recruit children from schools in Northern Ireland. Detailed eye examinations included assessment of logMAR visual acuity and cycloplegic autorefraction. Spherical equivalent refractive data from the right eye were used to classify significant refractive error as myopia of at least 1DS, hyperopia as greater than +3.50DS and astigmatism as greater than 1.50DC, whether it occurred in isolation or in association with myopia or hyperopia. RESULTS: Results are presented from 661 white 12-13-year-old and 392 white 6-7-year-old school-children. Using a cut-off of uncorrected visual acuity poorer than 0.20 logMAR to detect significant refractive error gave a sensitivity of 50% and specificity of 92% in 6-7-year-olds and 73% and 93% respectively in 12-13-year-olds. In 12-13-year-old children a cut-off of poorer than 0.20 logMAR had a sensitivity of 92% and a specificity of 91% in detecting myopia and a sensitivity of 41% and a specificity of 84% in detecting hyperopia. CONCLUSIONS: Vision screening using logMAR acuity can reliably detect myopia, but not hyperopia or astigmatism in school-age children. Providers of vision screening programs should be cognisant that where detection of uncorrected hyperopic and/or astigmatic refractive error is an aspiration, current UK protocols will not effectively deliver.

  13. Refractive errors in Cameroonians diagnosed with complete oculocutaneous albinism

    Directory of Open Access Journals (Sweden)

    Eballé AO

    2013-07-01

    Full Text Available André Omgbwa Eballé1,3, Côme Ebana Mvogo2, Christelle Noche4, Marie Evodie Akono Zoua2, Andin Viola Dohvoma21Faculty of Medicine and Pharmaceutical Sciences, University of Douala, Douala, Cameroon, 2Faculty of Medicine and Biomedical Sciences, University of Yaoundé I, Yaoundé, Cameroon; 3Yaoundé Gynaeco-obstetric and Paediatric Hospital. Yaoundé, Cameroon; 4Faculty of Medicine, Université des Montagnes. Bangangté, CameroonBackground: Albinism causes significant eye morbidity and amblyopia in children. The aim of this study was to determine the refractive state in patients with complete oculocutaneous albinism who were treated at the Gynaeco-Obstetric and Paediatric Hospital, Yaoundé, Cameroon and evaluate its effect on vision.Methods: We carried out this retrospective study at the ophthalmology unit of our hospital. All oculocutaneous albino patients who were treated between March 1, 2003 and December 31, 2011 were included.Results: Thirty-five patients (70 eyes diagnosed with complete oculocutaneous albinism were enrolled. Myopic astigmatism was the most common refractive error (40%. Compared with myopic patients, those with myopic astigmatism and hypermetropic astigmatism were four and ten times less likely, respectively, to demonstrate significant improvement in distance visual acuity following optical correction.Conclusion: Managing refractive errors is an important way to reduce eye morbidity-associated low vision in oculocutaneous albino patients.Keywords: albinism, visual acuity, refraction, Cameroon

  14. Refractive errors in presbyopic patients in Kano, Nigeria

    African Journals Online (AJOL)

    Annals of African Medicine, Vol. ... Information extracted includes patient's age, sex, and types of refractive error. ... All patients had basic eye examination and streak retinoscopy at two third meter working distance. ... symptoms may start earlier or later than this age .... presbyopia was associated with reduced workers'.

  15. Refractive errors and school performance in Brazzaville, Congo ...

    African Journals Online (AJOL)

    Background: Wearing glasses before ten years is becoming more common in developed countries. In black Africa, for cultural or irrational reasons, this attitude remains exceptional. This situation is a source of amblyopia and learning difficulties. Objective: To determine the role of refractive errors in school performance in ...

  16. Association between Ocular Sensory Dominance and Refractive Error Asymmetry.

    Directory of Open Access Journals (Sweden)

    Feng Jiang

    Full Text Available To investigate the association between ocular sensory dominance and interocular refractive error difference (IRED.A total of 219 subjects were recruited. The refractive errors were determined by objective refraction with a fixation target located 6 meters away. 176 subjects were myopic, with 83 being anisometropic (IRED ≥ 0.75 D. 43 subjects were hyperopic, with 22 being anisometropic. Sensory dominance was measured with a continuous flashing technique with the tested eye viewing a Gabor increasing in contrast and the fellow eye viewing a Mondrian noise decreasing in contrast. The log ratio of Mondrian to Gabor's contrasts was recorded when a subject just detected the tilting direction of the Gabor during each trial. T-test was used to compare the 50 values collected from each eye, and the t-value was used as a subject's ocular dominance index (ODI to quantify the degree of ocular dominance. A subject with ODI ≥ 2 (p < 0.05 had clear dominance and the eye with larger mean ratio was the dominant one. Otherwise, a subject had an unclear dominance.The anisometropic subjects had stronger ocular dominance in comparison to non-anisometropic subjects (rank-sum test, p < 0.01 for both myopic and hyperopic subjects. In anisometropic subjects with clear dominance, the amplitude of the anisometropia was correlated with ODI values (R = 0.42, p < 0.01 in myopic anisometropic subjects; R = 0.62, p < 0.01 in hyperopic anisometropic subjects. Moreover, the dominant eyes were more myopic in myopic anisometropic subjects (sign-test, p < 0.05 and less hyperopic in hyperopic anisometropic subjects (sign-test, p < 0.05.The degree of ocular sensory dominance is associated with interocular refractive error difference.

  17. Prevalence of uncorrected refractive errors in adults aged 30 years and above in a rural population in Pakistan

    International Nuclear Information System (INIS)

    Abdullah, A.S.; Azam, M.; Nigar, M.

    2015-01-01

    Uncorrected refractive errors are a leading cause of visual disability globally. This population-based study was done to estimate the prevalence of uncorrected refractive errors in adults aged 30 years and above of village Pawakah, Khyber Pakhtunkhwa (KPK), Pakistan. Methods: It was a cross-sectional survey in which 1000 individuals were included randomly. All the individuals were screened for uncorrected refractive errors and those whose visual acuity (VA) was found to be less than 6/6 were refracted. In whom refraction was found to be unsatisfactory (i.e., a best corrected visual acuity of <6/6) further examination was done to establish the cause for the subnormal vision. Results: A total of 917 subjects participated in the survey (response rate 92%). The prevalence of uncorrected refractive errors was found to be 23.97% among males and 20% among females. The prevalence of visually disabling refractive errors was 6.89% in males and 5.71% in females. The prevalence was seen to increase with age, with maximum prevalence in 51-60 years age group. Hypermetropia (10.14%) was found to be the commonest refractive error followed by Myopia (6.00%) and Astigmatism (5.6%). The prevalence of Presbyopia was 57.5% (60.45% in males and 55.23% in females). Poor affordability was the commonest barrier to the use of spectacles, followed by unawareness. Cataract was the commonest reason for impaired vision after refractive correction. The prevalence of blindness was 1.96% (1.53% in males and 2.28% in females) in this community with cataract as the commonest cause. Conclusions: Despite being the most easily avoidable cause of subnormal vision uncorrected refractive errors still account for a major proportion of the burden of decreased vision in this area. Effective measures for the screening and affordable correction of uncorrected refractive errors need to be incorporated into the health care delivery system. (author)

  18. Optical correction of refractive error for preventing and treating eye symptoms in computer users.

    Science.gov (United States)

    Heus, Pauline; Verbeek, Jos H; Tikka, Christina

    2018-04-10

    Computer users frequently complain about problems with seeing and functioning of the eyes. Asthenopia is a term generally used to describe symptoms related to (prolonged) use of the eyes like ocular fatigue, headache, pain or aching around the eyes, and burning and itchiness of the eyelids. The prevalence of asthenopia during or after work on a computer ranges from 46.3% to 68.5%. Uncorrected or under-corrected refractive error can contribute to the development of asthenopia. A refractive error is an error in the focusing of light by the eye and can lead to reduced visual acuity. There are various possibilities for optical correction of refractive errors including eyeglasses, contact lenses and refractive surgery. To examine the evidence on the effectiveness, safety and applicability of optical correction of refractive error for reducing and preventing eye symptoms in computer users. We searched the Cochrane Central Register of Controlled Trials (CENTRAL); PubMed; Embase; Web of Science; and OSH update, all to 20 December 2017. Additionally, we searched trial registries and checked references of included studies. We included randomised controlled trials (RCTs) and quasi-randomised trials of interventions evaluating optical correction for computer workers with refractive error for preventing or treating asthenopia and their effect on health related quality of life. Two authors independently assessed study eligibility and risk of bias, and extracted data. Where appropriate, we combined studies in a meta-analysis. We included eight studies with 381 participants. Three were parallel group RCTs, three were cross-over RCTs and two were quasi-randomised cross-over trials. All studies evaluated eyeglasses, there were no studies that evaluated contact lenses or surgery. Seven studies evaluated computer glasses with at least one focal area for the distance of the computer screen with or without additional focal areas in presbyopic persons. Six studies compared computer

  19. Refractive error study in young subjects: results from a rural area in Paraguay

    Directory of Open Access Journals (Sweden)

    Isabel Signes-Soler

    2017-03-01

    Full Text Available AIM: To evaluate the distribution of refractive error in young subjects in a rural area of Paraguay in the context of an international cooperation campaign for the prevention of blindness. METHODS: A sample of 1466 young subjects (ranging from 3 to 22 years old, with a mean age of 11.21±3.63 years old, were examined to assess their distance visual acuity (VA and refractive error. The first screening examination performed by trained volunteers, included visual acuity testing, autokeratometry and non-cycloplegic autorefraction. Inclusion criteria for a second complete cycloplegic eye examination by an optometrist were VA <20/25 (0.10 logMAR or 0.8 decimal and/or corneal astigmatism ≥1.50 D. RESULTS: An uncorrected distance VA of 0 logMAR (1.0 decimal was found in 89.2% of children. VA <20/25 and/or corneal astigmatism ≥1.50 D was found in 3.9% of children (n=57, with a prevalence of hyperopia of 5.2% (0.2% of the total in this specific group. Furthermore, myopia (spherical equivalent ≤-0.5 D was found in 37.7% of the refracted children (0.5% of the total. The prevalence of refractive astigmatism (cylinder ≤-1.50 D was 15.8% (0.6% of the total. Visual impairment (VI (0.05≤VA≤0.3 was found in 12/114 (0.4% of the refracted eyes. Main causes for VI were refractive error (58%, retinal problems (17%, 2/12, albinism (17%, 2/12 and unknown (8%, 1/12. CONCLUSION: A low prevalence of refractive error has been found in this rural area of Paraguay, with higher prevalence of myopia than of hyperopia.

  20. Long-Term Changes in Refractive Error and Clinical Evaluation in Partially Accommodative Esotropia after Surgery.

    Directory of Open Access Journals (Sweden)

    Shin Yeop Oh

    Full Text Available We investigate the changes in refractive error and clinical evaluation in partially accommodative esotropia(PAET after surgery. A total of 68 patients PAET who received at least 2 years of follow-up after surgery were enrolled in this study. We performed a retrospective study in patients who underwent unilateral or bilateral medial rectus recession for a non-accommodative component of PAET between January 2005 and March 2013. Patients were divided into groups according to the presence of dominancy (dominant, non-dominant, alternative eye, and presence of amblyopia (amblyopic, fellow, normal eye. Changes and changing pattern in SE refractive error were analyzed in all patients and compared between groups. Patients were divided into two groups, those weaned off of hyperopic glasses and those who continued using them, then factors that significantly influenced the continued use of glasses were analyzed. The changes and changing pattern in SE refractive error according to time after operation and presence of amblyopia or dominancy. The mean length of follow-up was 4.89±1.74 years after surgery and the mean change in SE refractive error rate per year was -0.284±0.411 diopters (D. The pattern of changes in the mean SE refractive error for those with dominant, non-dominant, and alternative eyes was not significantly different (p = 0.292. The pattern of changes in the mean SE refractive error for those with amblyopic, fellow, and normal eyes was significantly different (p = 0.0002. Patients were successfully weaned off of hyperopic glasses at an average age of 9.41±2.74 years. The average SE refractive error in the group weaned off of hyperopic glasses was significantly lower than that in the group maintained on hyperopic glasses (p = 0.0002. The change of SE refractive error in amblyopic eyes decreased less than that in fellow or normal eyes, which may be correlated with the presence of amblyopia. Patients with a smaller esodeviated angle without

  1. Refractive errors in patients attending a private hospital in Jos, Nigeria

    African Journals Online (AJOL)

    Six hundred one (20.7%) patients with distant VA which improved with refraction were considered for this analysis. Two hundred twenty one (36.8%) of patients with refractive error were visually impaired (VA <6/12-3/60). Blindness (<3/60 ‑ none perception of light) was seen in 91 (15.1%) of the patients, seven of whom were ...

  2. Modeling of mouse eye and errors in ocular parameters affecting refractive state

    Science.gov (United States)

    Bawa, Gurinder

    Rodents eye are particularly used to study refractive error state of an eye and development of refractive eye. Genetic organization of rodents is similar to that of humans, which makes them interesting candidates to be researched upon. From rodents family mice models are encouraged over rats because of availability of genetically engineered models. Despite of extensive work that has been performed on mice and rat models, still no one is able to quantify an optical model, due to variability in the reported ocular parameters. In this Dissertation, we have extracted ocular parameters and generated schematics of eye from the raw data from School of Medicine, Detroit. In order to see how the rays would travel through an eye and the defects associated with an eye; ray tracing has been performed using ocular parameters. Finally we have systematically evaluated the contribution of various ocular parameters, such as radii of curvature of ocular surfaces, thicknesses of ocular components, and refractive indices of ocular refractive media, using variational analysis and a computational model of the rodent eye. Variational analysis revealed that variation in all the ocular parameters does affect the refractive status of the eye, but depending upon the magnitude of the impact those parameters are listed as critical or non critical. Variation in the depth of the vitreous chamber, thickness of the lens, radius of the anterior surface of the cornea, radius of the anterior surface of the lens, as well as refractive indices for the lens and vitreous, appears to have the largest impact on the refractive error and thus are categorized as critical ocular parameters. The radii of the posterior surfaces of the cornea and lens have much smaller contributions to the refractive state, while the radii of the anterior and posterior surfaces of the retina have no effect on the refractive error. These data provide the framework for further refinement of the optical models of the rat and mouse

  3. ASSOCIATION BETWEEN REFRACTIVE ERRORS AND SENILE CATARACT IN RURAL AREA OF WESTERN MAHARASHTRA

    Directory of Open Access Journals (Sweden)

    Chaudhari Sagar V, Shelke Sanjay T, BangalSurekha V, Bhandari Akshay J, Kulkarni Ameya A

    2015-04-01

    Full Text Available Purpose: To study the association between refractive errors and senile cataract in rural area of western MaharashtraMaterials & Methods: It is a prospective cross sectional study carried out on 420 eyes of 210 patients with senile cataract was included in the study. The age and sex of the patient, grade and the refractive status of the cataract of the eyes were recorded. The grade of the cataract was recorded by the LOCS III (Lens Opacities Classification System, version III. Refractive status was measured subjectively using retinoscope and refractive error for each eye was converted into spherical equivalent units. Results: The age variation in the study was between 60-85 years.The maximum number of patients was in the age group of 60-65 years.The spherical equivalent ranged between -3.0 D to +4.25D.45.95% of the study population had a spherical equivalent between -2 to -1.73.81 % of the study population had a myopic refraction.20% had a hypermetropic refraction. Percentage of patients with a score of nuclear opalescence and colour between 1.0-2.0 was 41.90%, between 2.1-3.0 was 26.67% and above 3.0 was 31.43%.Percentage of patients with a score of cortical cataract between 0.1-1.0 was 69.76% and with a grade between 2.1-3.0 was 26.91 %. Percentage of patients with a score of posterior subcapsular cataract between 0.1-1.0 was 53.57% and with a grade between 2.1-3.0 was 39.05%. Conclusion: The myopic refraction was associated with nuclear, cortical and posterior subcapsular cataract and this refractive error was stastically significant with nuclear, cortical and posterior subcapsular cataract.

  4. Refractive errors in school children in Onitsha, Nigeria | Nwosu ...

    African Journals Online (AJOL)

    Refractive errors in school children in Onitsha, Nigeria. ... Abstract. Objectives: To determine the incidence and pattern of ametropia among school children. Materials and ... The cooperation of parents and teachers is vital in identifying and treating this modifiable cause of poor academic performance and learning difficulties.

  5. Refractive error, ocular biometry, and lens opalescence in an adult population: the Los Angeles Latino Eye Study.

    Science.gov (United States)

    Shufelt, Chrisandra; Fraser-Bell, Samantha; Ying-Lai, Mei; Torres, Mina; Varma, Rohit

    2005-12-01

    To characterize age- and gender-related differences in refractive error, ocular biometry, and lens opalescence (NOP) in a population-based sample of adult Latinos. Also assessed were the determinants of age-related refractive differences. Participants in the Los Angeles Latino Eye Study (LALES), a population-based study of Latinos aged 40 years and more, underwent an ophthalmic examination, including ultrasonic measurements of axial length (AL), vitreous chamber depth (VCD), anterior chamber depth (ACD), lens thickness (LT), and noncycloplegic automated and subjective refraction. Corneal curvature/power (CP) was measured using an autorefractor. NOP was graded at the slit lamp by an ophthalmologist using the Lens Opacity Classification System II. Age- and gender-related differences were calculated. Multiple regression models were used to identify the determinants of age-related refractive differences. Of the 6357 LALES participants, 5588 phakic individuals with biometric data were included in this analysis. Older individuals had shallower ACDs, thicker lenses, more NOP, and more hyperopia compared to younger individuals (P or = 0.05). Women had significantly shorter AL, shallower ACD and VCD, than did men (P < or = 0.01). The strongest determinants of refractive error were AL (primarily VCD) and CP. NOP was a small but significant determinant of refractive error in older individuals. Age- and gender-related differences in ocular biometric, refractive error, and NOP measurements are present in adult Latinos. While the relative contribution of NOP in determining refractive error is small, it is greater in older persons compared to younger individuals.

  6. Surgical Options for the Refractive Correction of Keratoconus: Myth or Reality

    Directory of Open Access Journals (Sweden)

    L. Fernández-Vega-Cueto

    2017-01-01

    Full Text Available Keratoconus provides a decrease of quality of life to the patients who suffer from it. The treatment used as well as the method to correct the refractive error of these patients may influence on the impact of the disease on their quality of life. The purpose of this review is to describe the evidence about the conservative surgical treatment for keratoconus aiming to therapeutic and refractive effect. The visual rehabilitation for keratoconic corneas requires addressing three concerns: halting the ectatic process, improving corneal shape, and minimizing the residual refractive error. Cross-linking can halt the disease progression, intrastromal corneal ring segments can improve the corneal shape and hence the visual quality and reduce the refractive error, PRK can correct mild-moderate refractive error, and intraocular lenses can correct from low to high refractive error associated with keratoconus. Any of these surgical options can be performed alone or combined with the other techniques depending on what the case requires. Although it could be considered that the surgical option for the refracto-therapeutic treatment of the keratoconus is a reality, controlled, randomized studies with larger cohorts and longer follow-up periods are needed to determine which refractive procedure and/or sequence are most suitable for each case.

  7. Refractive error and visual impairment in school children in Northern Ireland.

    Science.gov (United States)

    O'Donoghue, L; McClelland, J F; Logan, N S; Rudnicka, A R; Owen, C G; Saunders, K J

    2010-09-01

    To describe the prevalence of refractive error (myopia and hyperopia) and visual impairment in a representative sample of white school children. The Northern Ireland Childhood Errors of Refraction study, a population-based cross-sectional study, examined 661 white 12-13-year-old and 392 white 6-7-year-old children between 2006 and 2008. Procedures included assessment of monocular logarithm of the minimum angle of resolution (logMAR), visual acuity (unaided and presenting) and binocular open-field cycloplegic (1% cyclopentolate) autorefraction. Myopia was defined as -0.50DS or more myopic spherical equivalent refraction (SER) in either eye, hyperopia as > or =+2.00DS SER in either eye if not previously classified as myopic. Visual impairment was defined as >0.30 logMAR units (equivalent to 6/12). Levels of myopia were 2.8% (95% CI 1.3% to 4.3%) in younger and 17.7% (95% CI 13.2% to 22.2%) in older children: corresponding levels of hyperopia were 26% (95% CI 20% to 33%) and 14.7% (95% CI 9.9% to 19.4%). The prevalence of presenting visual impairment in the better eye was 3.6% in 12-13-year-old children compared with 1.5% in 6-7-year-old children. Almost one in four children fails to bring their spectacles to school. This study is the first to provide robust population-based data on the prevalence of refractive error and visual impairment in Northern Irish school children. Strategies to improve compliance with spectacle wear are required.

  8. Poor vision, refractive errors and barriers to treatment among ...

    African Journals Online (AJOL)

    Poor vision, refractive errors and barriers to treatment among commercial vehicle drivers in the Cape Coast municipality. ... were also administered to the participants to collect demographic data, history of driving and RTAs and utilization of eye care services as well as identification of the colours of the traffic light. Results: A ...

  9. Refractive optics to compensate x-ray mirror shape-errors

    Science.gov (United States)

    Laundy, David; Sawhney, Kawal; Dhamgaye, Vishal; Pape, Ian

    2017-08-01

    Elliptically profiled mirrors operating at glancing angle are frequently used at X-ray synchrotron sources to focus X-rays into sub-micrometer sized spots. Mirror figure error, defined as the height difference function between the actual mirror surface and the ideal elliptical profile, causes a perturbation of the X-ray wavefront for X- rays reflecting from the mirror. This perturbation, when propagated to the focal plane results in an increase in the size of the focused beam. At Diamond Light Source we are developing refractive optics that can be used to locally cancel out the wavefront distortion caused by figure error from nano-focusing elliptical mirrors. These optics could be used to correct existing optical components on synchrotron radiation beamlines in order to give focused X-ray beam sizes approaching the theoretical diffraction limit. We present our latest results showing measurement of the X-ray wavefront error after reflection from X-ray mirrors and the translation of the measured wavefront into a design for refractive optical elements for correction of the X-ray wavefront. We show measurement of the focused beam with and without the corrective optics inserted showing reduction in the size of the focus resulting from the correction to the wavefront.

  10. Management of Refractive Errors And Low Vision Among Basic ...

    African Journals Online (AJOL)

    The study sought to discuss the management of refractive errors and low vision among basic school children in the Atwima district. A sample of 1,177 public basic school children aged between 5-19 years was randomly selected from ten basic schools for examination. Thirteen key informants in the district were purposively ...

  11. Refractive Errors in Primary School Children in Nigeria | Faderin ...

    African Journals Online (AJOL)

    The study was carried out to determine the prevalence of refractive errors in primary school children in the Nigerian Army children school. Bonny Camp, Lagos, Nigeria. A total of 919 pupils from two primary schools (one private school and one public school) were screened. The schools and classes were selected using ...

  12. Refractive errors in students from Middle Eastern backgrounds living and undertaking schooling in Australia.

    Science.gov (United States)

    Azizoglu, Serap; Junghans, Barbara M; Barutchu, Ayla; Crewther, Sheila G

    2011-01-01

      Environmental factors associated with schooling systems in various countries have been implicated in the rising prevalence of myopia, making the comparison of prevalence of refractive errors in migrant populations of interest. This study aims to determine the prevalence of refractive errors in children of Middle Eastern descent, raised and living in urban Australia but actively maintaining strong ties to their ethnic culture, and to compare them with those in the Middle East where myopia prevalence is generally low.   A total of 354 out of a possible 384 late primary/early secondary schoolchildren attending a private school attracting children of Middle Eastern background in Melbourne were assessed for refractive error and visual acuity. A Shin Nippon open-field NVision-K5001 autorefractor was used to carry out non-cycloplegic autorefraction while viewing a distant target. For statistical analyses students were divided into three age groups: 10-11 years (n = 93); 12-13 years (n = 158); and 14-15 years (n = 102).   All children were bilingual and classified as of Middle Eastern (96.3 per cent) or Egyptian (3.7 per cent) origin. Ages ranged from 10 to 15 years, with a mean of 13.17 ± 0.8 (SEM) years. Mean spherical equivalent refraction (SER) for the right eye was +0.09 ± 0.07 D (SEM) with a range from -7.77 D to +5.85 D. The prevalence of myopia, defined as a spherical equivalent refraction 0.50 D or more of myopia, was 14.7 per cent. The prevalence of hyperopia, defined as a spherical equivalent refraction of +0.75 D or greater, was 16.4 per cent, while hyperopia of +1.50 D or greater was 5.4 per cent. A significant difference in SER was seen as a function of age; however, no significant gender difference was seen.   This is the first study to report the prevalence of refractive errors for second-generation Australian schoolchildren coming from a predominantly Lebanese Middle Eastern Arabic background, who endeavour to maintain their ethnic ties. The

  13. Refractive Error in a Sample of Black High School Children in South Africa.

    Science.gov (United States)

    Wajuihian, Samuel Otabor; Hansraj, Rekha

    2017-12-01

    This study focused on a cohort that has not been studied and who currently have limited access to eye care services. The findings, while improving the understanding of the distribution of refractive errors, also enabled identification of children requiring intervention and provided a guide for future resource allocation. The aim of conducting the study was to determine the prevalence and distribution of refractive error and its association with gender, age, and school grade level. Using a multistage random cluster sampling, 1586 children, 632 males (40%) and 954 females (60%), were selected. Their ages ranged between 13 and 18 years with a mean of 15.81 ± 1.56 years. The visual functions evaluated included visual acuity using the logarithm of minimum angle of resolution chart and refractive error measured using the autorefractor and then refined subjectively. Axis astigmatism was presented in the vector method where positive values of J0 indicated with-the-rule astigmatism, negative values indicated against-the-rule astigmatism, whereas J45 represented oblique astigmatism. Overall, patients were myopic with a mean spherical power for right eye of -0.02 ± 0.47; mean astigmatic cylinder power was -0.09 ± 0.27 with mainly with-the-rule astigmatism (J0 = 0.01 ± 0.11). The prevalence estimates were as follows: myopia (at least -0.50) 7% (95% confidence interval [CI], 6 to 9%), hyperopia (at least 0.5) 5% (95% CI, 4 to 6%), astigmatism (at least -0.75 cylinder) 3% (95% CI, 2 to 4%), and anisometropia 3% (95% CI, 2 to 4%). There was no significant association between refractive error and any of the categories (gender, age, and grade levels). The prevalence of refractive error in the sample of high school children was relatively low. Myopia was the most prevalent, and findings on its association with age suggest that the prevalence of myopia may be stabilizing at late teenage years.

  14. Retinal dysfunction and refractive errors: an electrophysiological study of children

    Science.gov (United States)

    Flitcroft, D I; Adams, G G W; Robson, A G; Holder, G E

    2005-01-01

    Aims: To evaluate the relation between refractive error and electrophysiological retinal abnormalities in children referred for investigation of reduced vision. Methods: The study group comprised 123 consecutive patients referred over a 14 month period from the paediatric service of Moorfields Eye Hospital for electrophysiological investigation of reduced vision. Subjects were divided into five refractive categories according to their spectacle correction: high myopia (⩽−6D), low myopia (>−6D and ⩽−0.75D), emmetropia (>−0.75 and 1.5D) and ERG abnormalities (18/35 with high astigmatism v 20/88 without, χ2 test, p = 0.002). There was no significant variation in frequency of abnormalities between low myopes, emmetropes, and low hyperopes. The rate of abnormalities was very similar in both high myopes (8/15) and high hyperopes (5/10). Conclusions: High ametropia and astigmatism in children being investigated for poor vision are associated with a higher rate of retinal electrophysiological abnormalities. An increased rate of refractive errors in the presence of retinal pathology is consistent with the hypothesis that the retina is involved in the process of emmetropisation. Electrophysiological testing should be considered in cases of high ametropia in childhood to rule out associated retinal pathology. PMID:15774929

  15. Prevalence of Refractive errors in Primary school children in a rural ...

    African Journals Online (AJOL)

    Prevalence of Refractive errors in Primary school children in a rural community in Ebonyi state of Nigeria. ... PROMOTING ACCESS TO AFRICAN RESEARCH ... However, no previous vision screening study among primary schools children ...

  16. Prevalence of refractive error in malay primary school children in suburban area of Kota Bharu, Kelantan, Malaysia.

    Science.gov (United States)

    Hashim, Syaratul-Emma; Tan, Hui-Ken; Wan-Hazabbah, W H; Ibrahim, Mohtar

    2008-11-01

    Refractive error remains one of the primary causes of visual impairment in children worldwide, and the prevalence of refractive error varies widely. The objective of this study was to determine the prevalence of refractive error and study the possible associated factors inducing refractive error among primary school children of Malay ethnicity in the suburban area of Kota Bharu, Kelantan, Malaysia. A school-based cross-sectional study was performed from January to July 2006 by random selection on Standard 1 to Standard 6 students of 10 primary schools in the Kota Bharu district. Visual acuity assessment was measured using logMAR ETDRS chart. Positive predictive value of uncorrected visual acuity equal or worse than 20/40, was used as a cut-off point for further evaluation by automated refraction and retinoscopic refraction. A total of 840 students were enumerated but only 705 were examined. The prevalence of uncorrected visual impairment was seen in 54 (7.7%) children. The main cause of the uncorrected visual impairment was refractive error which contributed to 90.7% of the total, and with 7.0% prevalence for the studied population. Myopia is the most common type of refractive error among children aged 6 to 12 years with prevalence of 5.4%, followed by hyperopia at 1.0% and astigmatism at 0.6%. A significant positive correlation was noted between myopia development with increasing age (P <0.005), more hours spent on reading books (P <0.005) and background history of siblings with glasses (P <0.005) and whose parents are of higher educational level (P <0.005). Malays in suburban Kelantan (5.4%) have the lowest prevalence of myopia compared with Malays in the metropolitan cities of Kuala Lumpur (9.2%) and Singapore (22.1%). The ethnicity-specific prevalence rate of myopia was the lowest among Malays in Kota Bharu, followed by Kuala Lumpur, and is the highest among Singaporean Malays. Better socio-economic factors could have contributed to higher myopia rates in the

  17. Prevalence of refractive error and visual impairment among rural school-age children of Goro District, Gurage Zone, Ethiopia.

    Science.gov (United States)

    Kedir, Jafer; Girma, Abonesh

    2014-10-01

    Refractive error is one of the major causes of blindness and visual impairment in children; but community based studies are scarce especially in rural parts of Ethiopia. So, this study aims to assess the prevalence of refractive error and its magnitude as a cause of visual impairment among school-age children of rural community. This community-based cross-sectional descriptive study was conducted from March 1 to April 30, 2009 in rural villages of Goro district of Gurage Zone, found south west of Addis Ababa, the capital of Ethiopia. A multistage cluster sampling method was used with simple random selection of representative villages in the district. Chi-Square and t-tests were used in the data analysis. A total of 570 school-age children (age 7-15) were evaluated, 54% boys and 46% girls. The prevalence of refractive error was 3.5% (myopia 2.6% and hyperopia 0.9%). Refractive error was the major cause of visual impairment accounting for 54% of all causes in the study group. No child was found wearing corrective spectacles during the study period. Refractive error was the commonest cause of visual impairment in children of the district, but no measures were taken to reduce the burden in the community. So, large scale community level screening for refractive error should be conducted and integrated with regular school eye screening programs. Effective strategies need to be devised to provide low cost corrective spectacles in the rural community.

  18. Reducing visual deficits caused by refractive errors in school and preschool children: results of a pilot school program in the Andean region of Apurimac, Peru

    Science.gov (United States)

    Latorre-Arteaga, Sergio; Gil-González, Diana; Enciso, Olga; Phelan, Aoife; García-Muñoz, Ángel; Kohler, Johannes

    2014-01-01

    Background Refractive error is defined as the inability of the eye to bring parallel rays of light into focus on the retina, resulting in nearsightedness (myopia), farsightedness (Hyperopia) or astigmatism. Uncorrected refractive error in children is associated with increased morbidity and reduced educational opportunities. Vision screening (VS) is a method for identifying children with visual impairment or eye conditions likely to lead to visual impairment. Objective To analyze the utility of vision screening conducted by teachers and to contribute to a better estimation of the prevalence of childhood refractive errors in Apurimac, Peru. Design A pilot vision screening program in preschool (Group I) and elementary school children (Group II) was conducted with the participation of 26 trained teachers. Children whose visual acuity was<6/9 [20/30] (Group I) and≤6/9 (Group II) in one or both eyes, measured with the Snellen Tumbling E chart at 6 m, were referred for a comprehensive eye exam. Specificity and positive predictive value to detect refractive error were calculated against clinical examination. Program assessment with participants was conducted to evaluate outcomes and procedures. Results A total sample of 364 children aged 3–11 were screened; 45 children were examined at Centro Oftalmológico Monseñor Enrique Pelach (COMEP) Eye Hospital. Prevalence of refractive error was 6.2% (Group I) and 6.9% (Group II); specificity of teacher vision screening was 95.8% and 93.0%, while positive predictive value was 59.1% and 47.8% for each group, respectively. Aspects highlighted to improve the program included extending training, increasing parental involvement, and helping referred children to attend the hospital. Conclusion Prevalence of refractive error in children is significant in the region. Vision screening performed by trained teachers is a valid intervention for early detection of refractive error, including screening of preschool children. Program

  19. Refractive errors progression among pupils in Hetian Road primary school of Shanghai: 1-year followed-up

    Directory of Open Access Journals (Sweden)

    Hui Shi

    2013-12-01

    Full Text Available AIM:To investigate the progression of refractive errors of pupils in Hetian Road primary school of Shanghai Zhabei community and analyze the relationship between refractive errors progression and relative factors. METHODS:All the 6-12 years old in-school pupils in Hetian Road primary school of Shanghai Zhabei community were invited in the study. The participates were examined first-visit in May 2011 and second-visit in May 2012. All the 303 pupils(606 eyeswere investigated the age, height(H, weight(W, uncorrected visual acuity(UCVA, diopter of spherical(DS, diopter of cylinder(DC, spherical equivalent(SE, axial length(AL, and corneal curvature(K. The progression of refractive condition was described and the relevant factors were analyzed.RESULTS:Among 606 eyes, the progression of average SE was -0.45±0.60D and the progression of average AL was 0.32±0.25mm. The progression of SE diopter was positively correlated with the progression of AL(r=0.409, PP=0.004. The youngest pupils with 6-8 years old, had the fastest progression of AL(0.39±0.24mm, PP>0.05. The incidence of poor sight(UCVACONCLUSION:Myopia is the main progression of refractive error in the pupils of Hetian Road primary school in Shanghai Zhabei community. AL and growth development is closely related to the progression of refractive errors.

  20. Contribution of refractive errors to visual impairment in patients at ...

    African Journals Online (AJOL)

    Objective: To determine the contribution of refractive error to visual impairment in visually impaired patients attending Korle-Bu Teaching Hospital, Ghana. Method: This study was conducted over a period of 1 year beginning October 2002 at Korle-Bu Teaching Hospital. Every 4th consecutive new case attending the eye ...

  1. Investigating the relationship between foveal morphology and refractive error in a population with infantile nystagmus syndrome.

    Science.gov (United States)

    Healey, Natasha; McLoone, Eibhlin; Mahon, Gerald; Jackson, A Jonathan; Saunders, Kathryn J; McClelland, Julie F

    2013-04-26

    We explored associations between refractive error and foveal hypoplasia in infantile nystagmus syndrome (INS). We recruited 50 participants with INS (albinism n = 33, nonalbinism infantile nystagmus [NAIN] n = 17) aged 4 to 48 years. Cycloplegic refractive error and logMAR acuity were obtained. Spherical equivalent (SER), most ametropic meridian (MAM) refractive error, and better eye acuity (VA) were used for analyses. High resolution spectral-domain optical coherence tomography (SD-OCT) was used to obtain foveal scans, which were graded using the Foveal Hypoplasia Grading Scale. Associations between grades of severity of foveal hypoplasia, and refractive error and VA were explored. Participants with more severe foveal hypoplasia had significantly higher MAMs and SERs (Kruskal-Wallis H test P = 0.005 and P = 0.008, respectively). There were no statistically significant associations between foveal hypoplasia and cylindrical refractive error (Kruskal-Wallis H test P = 0.144). Analyses demonstrated significant differences between participants with albinism or NAIN in terms of SER and MAM (Mann-Whitney U test P = 0.001). There were no statistically significant differences between astigmatic errors between participants with albinism and NAIN. Controlling for the effects of albinism, results demonstrated no significant associations between SER, and MAM and foveal hypoplasia (partial correlation P > 0.05). Poorer visual acuity was associated statistically significantly with more severe foveal hypoplasia (Kruskal-Wallis H test P = 0.001) and with a diagnosis of albinism (Mann-Whitney U test P = 0.001). Increasing severity of foveal hypoplasia is associated with poorer VA, reflecting reduced cone density in INS. Individuals with INS also demonstrate a significant association between more severe foveal hypoplasia and increasing hyperopia. However, in the absence of albinism, there is no significant relation between refractive outcome and degree of foveal hypoplasia

  2. Refractive regression after laser in situ keratomileusis.

    Science.gov (United States)

    Yan, Mabel K; Chang, John Sm; Chan, Tommy Cy

    2018-04-26

    Uncorrected refractive errors are a leading cause of visual impairment across the world. In today's society, laser in situ keratomileusis (LASIK) has become the most commonly performed surgical procedure to correct refractive errors. However, regression of the initially achieved refractive correction has been a widely observed phenomenon following LASIK since its inception more than two decades ago. Despite technological advances in laser refractive surgery and various proposed management strategies, post-LASIK regression is still frequently observed and has significant implications for the long-term visual performance and quality of life of patients. This review explores the mechanism of refractive regression after both myopic and hyperopic LASIK, predisposing risk factors and its clinical course. In addition, current preventative strategies and therapies are also reviewed. © 2018 Royal Australian and New Zealand College of Ophthalmologists.

  3. distribution of refractive errors among school children in abia state of ...

    African Journals Online (AJOL)

    children have greater access to computers, television, better libraries and regular electricity supply which could also motivate more night reading may make an acceptable explanation for this. However, it is the recommendation of the researcher that the effects of environmental factors on the distribution of refractive errors be.

  4. Nature versus nurture: A systematic approach to elucidate gene-environment interactions in the development of myopic refractive errors.

    Science.gov (United States)

    Miraldi Utz, Virginia

    2017-01-01

    Myopia is the most common eye disorder and major cause of visual impairment worldwide. As the incidence of myopia continues to rise, the need to further understand the complex roles of molecular and environmental factors controlling variation in refractive error is of increasing importance. Tkatchenko and colleagues applied a systematic approach using a combination of gene set enrichment analysis, genome-wide association studies, and functional analysis of a murine model to identify a myopia susceptibility gene, APLP2. Differential expression of refractive error was associated with time spent reading for those with low frequency variants in this gene. This provides support for the longstanding hypothesis of gene-environment interactions in refractive error development.

  5. Association between Refractive Errors and Ocular Biometry in Iranian Adults

    Science.gov (United States)

    Hashemi, Hassan; Khabazkhoob, Mehdi; Emamian, Mohammad Hassan; Shariati, Mohammad; Miraftab, Mohammad; Yekta, Abbasali; Ostadimoghaddam, Hadi; Fotouhi, Akbar

    2015-01-01

    Purpose: To investigate the association between ocular biometrics such as axial length (AL), anterior chamber depth (ACD), lens thickness (LT), vitreous chamber depth (VCD) and corneal power (CP) with different refractive errors. Methods: In a cross-sectional study on the 40 to 64-year-old population of Shahroud, random cluster sampling was performed. Ocular biometrics were measured using the Allegro Biograph (WaveLight AG, Erlangen, Germany) for all participants. Refractive errors were determined using cycloplegic refraction. Results: In the first model, the strongest correlations were found between spherical equivalent with axial length and corneal power. Spherical equivalent was strongly correlated with axial length in high myopic and high hyperopic cases, and with corneal power in high hyperopic cases; 69.5% of variability in spherical equivalent was attributed to changes in these variables. In the second model, the correlations between vitreous chamber depth and corneal power with spherical equivalent were stronger in myopes than hyperopes, while the correlations between lens thickness and anterior chamber depth with spherical equivalent were stronger in hyperopic cases than myopic ones. In the third model, anterior chamber depth + lens thickness correlated with spherical equivalent only in moderate and severe cases of hyperopia, and this index was not correlated with spherical equivalent in moderate to severe myopia. Conclusion: In individuals aged 40-64 years, corneal power and axial length make the greatest contribution to spherical equivalent in high hyperopia and high myopia. Anterior segment biometric components have a more important role in hyperopia than myopia. PMID:26730304

  6. Prevalence of amblyopia and refractive errors among primary school children

    Directory of Open Access Journals (Sweden)

    Zhale Rajavi

    2015-01-01

    Results: Amblyopia was present in 2.3% (95% CI: 1.8% to 2.9% of participants with no difference between the genders. Amblyopic subjects were significantly younger than non-amblyopic children (P=0.004. Overall, 15.9% of hyperopic and 5.9% of myopic cases had amblyopia. The prevalence of hyperopia ≥+2.00D, myopia ≤-0.50D, astigmatism ≥0.75D, and anisometropia (≥1.00D was 3.5%, 4.9%, 22.6%, and 3.9%, respectively. With increasing age, the prevalence of myopia increased (P<0.001, that of hyperopia decreased (P=0.007, but astigmatism showed no change. Strabismus was found in 2.3% of cases. Strabismus (OR=17.9 and refractive errors, especially anisometropia (OR=12.87 and hyperopia (OR=11.87, were important amblyogenic risk factors. Conclusion: The high prevalence of amblyopia in our subjects in comparison to developed countries reveals the necessity of timely and sensitive screening methods. Due to the high prevalence of amblyopia among children with refractive errors, particularly high hyperopia and anisometropia, provision of glasses should be specifically attended by parents and supported by the Ministry of Health and insurance organizations.

  7. Piggyback intraocular lens implantation to correct pseudophakic refractive error after segmental multifocal intraocular lens implantation.

    Science.gov (United States)

    Venter, Jan A; Oberholster, Andre; Schallhorn, Steven C; Pelouskova, Martina

    2014-04-01

    To evaluate refractive and visual outcomes of secondary piggyback intraocular lens implantation in patients diagnosed as having residual ametropia following segmental multifocal lens implantation. Data of 80 pseudophakic eyes with ametropia that underwent Sulcoflex aspheric 653L intraocular lens implantation (Rayner Intraocular Lenses Ltd., East Sussex, United Kingdom) to correct residual refractive error were analyzed. All eyes previously had in-the-bag zonal refractive multifocal intraocular lens implantation (Lentis Mplus MF30, models LS-312 and LS-313; Oculentis GmbH, Berlin, Germany) and required residual refractive error correction. Outcome measurements included uncorrected distance visual acuity, corrected distance visual acuity, uncorrected near visual acuity, distance-corrected near visual acuity, manifest refraction, and complications. One-year data are presented in this study. The mean spherical equivalent ranged from -1.75 to +3.25 diopters (D) preoperatively (mean: +0.58 ± 1.15 D) and reduced to -1.25 to +0.50 D (mean: -0.14 ± 0.28 D; P < .01). Postoperatively, 93.8% of eyes were within ±0.50 D and 98.8% were within ±1.00 D of emmetropia. The mean uncorrected distance visual acuity improved significantly from 0.28 ± 0.16 to 0.01 ± 0.10 logMAR and 78.8% of eyes achieved 6/6 (Snellen 20/20) or better postoperatively. The mean uncorrected near visual acuity changed from 0.43 ± 0.28 to 0.19 ± 0.15 logMAR. There was no significant change in corrected distance visual acuity or distance-corrected near visual acuity. No serious intraoperative or postoperative complications requiring secondary intraocular lens removal occurred. Sulcoflex lenses proved to be a predictable and safe option for correcting residual refractive error in patients diagnosed as having pseudophakia. Copyright 2014, SLACK Incorporated.

  8. Refractive errors, visual impairment, and the use of low-vision devices in albinism in Malawi.

    Science.gov (United States)

    Schulze Schwering, M; Kumar, N; Bohrmann, D; Msukwa, G; Kalua, K; Kayange, P; Spitzer, M S

    2015-04-01

    This study focuses on the refractive implications of albinism in Malawi, which is mostly associated with the burden of visual impairment. The main goal was to describe the refractive errors and to analyze whether patients with albinism in Malawi, Sub-Saharan Africa, benefit from refraction. Age, sex, refractive data, uncorrected and best-corrected visual acuity (UCVA, BCVA), colour vision, contrast sensitivity, and the prescription of sunglasses and low vision devices were collected for a group of 120 albino individuals with oculocutaneous albinism (OCA). Refractive errors were evaluated objectively and subjectively by retinoscopy, and followed by cycloplegic refraction to reconfirm the results. Best-corrected visual acuity (BCVA) was also assessed binocularly. One hundred and twenty albino subjects were examined, ranging in age from 4 to 25 years (median 12 years), 71 (59 %) boys and 49 (41 %) girls. All exhibited horizontal pendular nystagmus. Mean visual acuity improved from 0.98 (0.33) logMAR to 0.77 (0.15) logMAR after refraction (p < 0.001). The best improvement of VA was achieved in patients with mild to moderate myopia. Patients with albinism who were hyperopic more than +1.5 D hardly improved from refraction. With the rule (WTR) astigmatism was more present (37.5 %) than against the rule (ATR) astigmatism (3.8 %). Patients with astigmatism less than 1.5 D improved in 15/32 of cases (47 %) by 2 lines or more. Patients with astigmatism equal to or more than 1.5 D in any axis improved in 26/54 of cases (48 %) by 2 lines or more. Refraction improves visual acuity of children with oculocutaneous albinism in a Sub-Saharan African population in Malawi. The mean improvement was 2 logMAR units.

  9. Refractive errors in patients attending a private hospital in Jos, Nigeria

    African Journals Online (AJOL)

    2013-05-02

    May 2, 2013 ... of 6/9 or less and showed improvement in distance vision of one or more ... ninety eight patients were seen at the hospital for various eye problems. ... Two hundred twenty one (36.8%) of patients with refractive error were ... Other risk factors are ..... Myopia profile in Copenhagen medical students 1996‑98.

  10. Assessing the accuracy and feasibility of a refractive error screening program conducted by school teachers in pre-primary and primary schools in Thailand.

    Science.gov (United States)

    Teerawattananon, Kanlaya; Myint, Chaw-Yin; Wongkittirux, Kwanjai; Teerawattananon, Yot; Chinkulkitnivat, Bunyong; Orprayoon, Surapong; Kusakul, Suwat; Tengtrisorn, Supaporn; Jenchitr, Watanee

    2014-01-01

    As part of the development of a system for the screening of refractive error in Thai children, this study describes the accuracy and feasibility of establishing a program conducted by teachers. To assess the accuracy and feasibility of screening by teachers. A cross-sectional descriptive and analytical study was conducted in 17 schools in four provinces representing four geographic regions in Thailand. A two-staged cluster sampling was employed to compare the detection rate of refractive error among eligible students between trained teachers and health professionals. Serial focus group discussions were held for teachers and parents in order to understand their attitude towards refractive error screening at schools and the potential success factors and barriers. The detection rate of refractive error screening by teachers among pre-primary school children is relatively low (21%) for mild visual impairment but higher for moderate visual impairment (44%). The detection rate for primary school children is high for both levels of visual impairment (52% for mild and 74% for moderate). The focus group discussions reveal that both teachers and parents would benefit from further education regarding refractive errors and that the vast majority of teachers are willing to conduct a school-based screening program. Refractive error screening by health professionals in pre-primary and primary school children is not currently implemented in Thailand due to resource limitations. However, evidence suggests that a refractive error screening program conducted in schools by teachers in the country is reasonable and feasible because the detection and treatment of refractive error in very young generations is important and the screening program can be implemented and conducted with relatively low costs.

  11. Intelligent Planning for Laser Refractive Surgeries

    Science.gov (United States)

    Wang, Wei; Yue, Yong; Elsheikh, Ahmed; Bao, Fangjun

    2018-02-01

    Refractive error is one of leading ophthalmic diseases for both genders all over the world. Laser refractive correction surgery, e.g., laser in-situ keratomileusis (LASIK), has been commonly used worldwide. The prediction of surgical parameters, e.g., corneal ablation depth, depends on the doctor’s experience, theoretical formula and surgery reference manual in the preoperative diagnosis. The error of prediction may present a potential surgical risk and complication. Being aware of the surgery parameters is important because these can be used to estimate a patient’s post-operative visual quality and help the surgeon plan a suitable treatment. Therefore, in this paper we discuss data mining techniques that can be utilized for the prediction of laser refractive correction surgery parameters. It can provide the surgeon with a reference for possible surgical parameters and outcomes of the patient before the laser refractive correction surgery.

  12. The Social and Economic Impact of Refractive Error in Mozambique

    OpenAIRE

    Thompson, Stephen James

    2014-01-01

    The purpose of this thesis is to investigate potential key determinants of the success, or otherwise, of endeavours to address avoidable Visual Impairment (VI) by addressing Uncorrected Refractive Error (URE) in Mozambique and the wider region of sub-Saharan Africa by providing optometric services. It includes a Cost Benefit Analysis (CBA) of a higher education optometry training programme, barriers that might prevent the realisation of overarching goals despite a successful training programm...

  13. Image sensor for testing refractive error of eyes

    Science.gov (United States)

    Li, Xiangning; Chen, Jiabi; Xu, Longyun

    2000-05-01

    It is difficult to detect ametropia and anisometropia for children. Image sensor for testing refractive error of eyes does not need the cooperation of children and can be used to do the general survey of ametropia and anisometropia for children. In our study, photographs are recorded by a CCD element in a digital form which can be directly processed by a computer. In order to process the image accurately by digital technique, formula considering the effect of extended light source and the size of lens aperture has been deduced, which is more reliable in practice. Computer simulation of the image sensing is made to verify the fineness of the results.

  14. Ocular wavefront aberration and refractive error in pre-school children

    Science.gov (United States)

    Thapa, Damber; Fleck, Andre; Lakshminarayanan, Vasudevan; Bobier, William R.

    2011-11-01

    Hartmann-Shack images taken from an archived collection of SureSight refractive measurements of pre-school children in Oxford County, Ontario, Canada were retrieved and re-analyzed. Higher-order aberrations were calculated over the age range of 3 to 6 years. These higher-order aberrations were compared with respect to magnitudes of ametropia. Subjects were classified as emmetropic (range -0.5 to + 0.5D), low hyperopic (+ 0.5 to +2D) and high hyperopic (+2D or more) based upon the resulting spherical equivalent. Higher-order aberrations were found to increase with higher levels of hyperopia (p < 0.01). The strongest effect was for children showing more than +2.00D of hyperopia. The correlation coefficients were small in all of the higher-order aberrations; however, they were significant (p < 0.01). These analyses indicate a weak association between refractive error and higher-order aberrations in pre-school children.

  15. Amblyopia and refractive errors among school-aged children with low socioeconomic status in southeastern Turkey.

    Science.gov (United States)

    Caca, Ihsan; Cingu, Abdullah Kursat; Sahin, Alparslan; Ari, Seyhmus; Dursun, Mehmet Emin; Dag, Umut; Balsak, Selahattin; Alakus, Fuat; Yavuz, Abdullah; Palanci, Yilmaz

    2013-01-01

    To investigate the prevalence of refractive errors and other eye diseases, incidence and types of amblyopia in school-aged children, and their relation to gender, age, parental education, and socioeconomic factors. A total of 21,062 children 6 to 14 years old were screened. The examination included visual acuity measurements and ocular motility evaluation. Autorefraction under cycloplegia and examination of the external eye, anterior segment, media, and fundus were performed. There were 11,118 females and 9,944 males. The average age was 10.56 ± 3.59 years. When all of the children were evaluated, 3.2% had myopia and 5.9% had hyperopia. Astigmatism 0.50 D or greater was present in 14.3% of children. Myopia was associated with older age, female gender, and higher parental education. Hyperopia was inversely proportional with older age. Spectacles were needed in 4,476 (22.7%) children with refractive errors, and 10.6% of children were unaware of their spectacle needs. Amblyopia was detected in 2.6% of all children. The most common causes of amblyopia were anisometropia (1.2%) and strabismus (0.9%). Visual impairment is a common disorder in school-aged children. Eye health screening programs are beneficial in early detection and proper treatment of refractive errors. Copyright 2013, SLACK Incorporated.

  16. An international collaborative family-based whole genome quantitative trait linkage scan for myopic refractive error

    DEFF Research Database (Denmark)

    Abbott, Diana; Li, Yi-Ju; Guggenheim, Jeremy A

    2012-01-01

    To investigate quantitative trait loci linked to refractive error, we performed a genome-wide quantitative trait linkage analysis using single nucleotide polymorphism markers and family data from five international sites....

  17. Common Mechanisms Underlying Refractive Error Identified in Functional Analysis of Gene Lists From Genome-Wide Association Study Results in 2 European British Cohorts

    Science.gov (United States)

    Hysi, Pirro G.; Mahroo, Omar A.; Cumberland, Phillippa; Wojciechowski, Robert; Williams, Katie M.; Young, Terri L.; Mackey, David A.; Rahi, Jugnoo S.; Hammond, Christopher J.

    2014-01-01

    IMPORTANCE To date, relatively few genes responsible for a fraction of heritability have been identified by means of large genetic association studies of refractive error. OBJECTIVE To explore the genetic mechanisms that lead to refractive error in the general population. DESIGN, SETTING, AND PARTICIPANTS Genome-wide association studies were carried out in 2 British population-based independent cohorts (N = 5928 participants) to identify genes moderately associated with refractive error. MAIN OUTCOMES AND MEASURES Enrichment analyses were used to identify sets of genes overrepresented in both cohorts. Enriched groups of genes were compared between both participating cohorts as a further measure against random noise. RESULTS Groups of genes enriched at highly significant statistical levels were remarkably consistent in both cohorts. In particular, these results indicated that plasma membrane (P = 7.64 × 10−30), cell-cell adhesion (P = 2.42 × 10−18), synaptic transmission (P = 2.70 × 10−14), calcium ion binding (P = 3.55 × 10−15), and cation channel activity (P = 2.77 × 10−14) were significantly overrepresented in relation to refractive error. CONCLUSIONS AND RELEVANCE These findings provide evidence that development of refractive error in the general population is related to the intensity of photosignal transduced from the retina, which may have implications for future interventions to minimize this disorder. Pathways connected to the procession of the nerve impulse are major mechanisms involved in the development of refractive error in populations of European origin. PMID:24264139

  18. Knowledge, attitude and associated factors among primary school teachers regarding refractive error in school children in Gondar city, Northwest Ethiopia.

    Science.gov (United States)

    Alemayehu, Abiy Maru; Belete, Gizchewu Tilahun; Adimassu, Nebiyat Feleke

    2018-01-01

    Refractive error is an important cause of correctable visual impairment in the worldwide with a global distribution of 1.75% to 20.7% among schoolchildren. Teacher's knowledge about refractive error play an important role in encouraging students to seek treatment that helps in reducing the burden of visual impairment. To determine knowledge, attitude and associated factors among primary school teachers regarding refractive error in school children in Gondar city. Institution based cross-sectional study was conducted on 565 primary school teachers in Gondar city using pretested and structured self-administered questionnaire. For processing and analysis, SPSS version 20 was used and variables which had a P value of attitude towards refractive error. History of spectacle use [AOR = 2.13 (95% CI: 1.32, 3.43)], history of eye examination [AOR = 1.67 (95% CI: 1.19, 2.34)], training on eye health [AOR = 1.94 (95% CI; 1.09, 3.43)] and 11-20 years of experience [AOR = 2.53 (95% CI: 1.18, 5.43)] were positively associated with knowledge. Whereas being male [AOR = 2.03 (95% CI: 1.37, 3.01)], older age [AOR = 3.05 (95% CI: 1.07, 8.72)], 31-40 years of experience [AOR = 0.23 (95% CI: 0.07, 0.72)], private school type [AOR = 1.76 (95% CI: 1.06, 2.93)] and 5th -8th teaching category [AOR = 1.54 (95% CI: 1.05, 2.24)] were associated with attitude. Knowledge and attitude of study subjects were low which needs training of teachers about the refractive error.

  19. [Improvement of vision through perceptual learning in the case of refractive errors and presbyopia : A critical valuation].

    Science.gov (United States)

    Heinrich, S P

    2017-02-01

    The idea of compensating or even rectifying refractive errors and presbyopia with the help of vision training is not new. For most approaches, however, scientific evidence is insufficient. A currently promoted method is "perceptual learning", which is assumed to improve stimulus processing in the brain. The basic phenomena of perceptual learning have been demonstrated by a multitude of studies. Some of these specifically address the case of refractive errors and presbyopia. However, many open questions remain, in particular with respect to the transfer of practice effects to every-day vision. At present, the method should therefore be judged with caution.

  20. Nine Loci for Ocular Axial Length Identified through Genome-wide Association Studies, Including Shared Loci with Refractive Error

    NARCIS (Netherlands)

    Cheng, Ching-Yu; Schache, Maria; Ikram, M. Kamran; Young, Terri L.; Guggenheim, Jeremy A.; Vitart, Veronique; Macgregor, Stuart; Verhoeven, Virginie J. M.; Barathi, Veluchamy A.; Liao, Jiemin; Hysi, Pirro G.; Bailey-Wilson, Joan E.; St Pourcain, Beate; Kemp, John P.; McMahon, George; Timpson, Nicholas J.; Evans, David M.; Montgomery, Grant W.; Mishra, Aniket; Wang, Ya Xing; Wang, Jie Jin; Rochtchina, Elena; Polasek, Ozren; Wright, Alan F.; Amin, Najaf; van Leeuwen, Elisabeth M.; Wilson, James F.; Pennell, Craig E.; van Duijn, Cornelia M.; de Jong, Paulus T. V. M.; Vingerling, Johannes R.; Zhou, Xin; Chen, Peng; Li, Ruoying; Tay, Wan-Ting; Zheng, Yingfeng; Chew, Merwyn; Burdon, Kathryn P.; Craig, Jamie E.; Iyengar, Sudha K.; Igo, Robert P.; Lass, Jonathan H.; Chew, Emily Y.; Haller, Toomas; Mihailov, Evelin; Metspalu, Andres; Wedenoja, Juho; Simpson, Claire L.; Wojciechowski, Robert; Chen, Wei

    2013-01-01

    Refractive errors are common eye disorders of public health importance worldwide. Ocular axial length (AL) is the major determinant of refraction and thus of myopia and hyperopia. We conducted a meta-analysis of genome-wide association studies for AL, combining 12,531 Europeans and 8,216 Asians. We

  1. The status of refractive errors in elementary school children in South Jeolla Province, South Korea

    Directory of Open Access Journals (Sweden)

    Jang JU

    2015-07-01

    Full Text Available Jung Un Jang,1 Inn-Jee Park2 1Department of Optometry, Eulji University, Seongnam, 2Department of Optometry, Kaya University, Gimhae, South Korea Purpose: To assess the prevalence of refractive errors among elementary school children in South Jeolla Province of South Korea. Methods: The subjects were aged 8–13 years; a total of 1,079 elementary school children from Mokpo, South Jeolla Province, were included. In all participants, uncorrected visual acuity and objective and subjective refractions were determined using auto Ref-Keratometer and phoropter. A spherical equivalent of -0.50 diopter (D or worse was defined as myopia, +0.50 D or more was defined as hyperopia, and a cylinder refraction greater than 0.75 D was defined as astigmatism. Results: Out of 1,079 elementary school children, the prevalence of uncorrected, best-corrected, and corrected visual acuity with own spectacles of 20/40 or worse in the better eye was 26.1%, 0.4%, and 20.2%, respectively. The uncorrected visual acuity was 20/200 or worse in the better eye in 5.7% of school children, and 5.2% of them already wore corrective spectacles. The prevalence of myopia, hyperopia, and astigmatism was 46.5% (95% confidence interval [CI]: 43.56–49.5, 6.2% (95% CI: 4.92–7.81, and 9.4% (95% CI: 7.76–11.25, respectively. Conclusion: The present study reveals a considerably higher prevalence of refractive error among elementary school children in South Jeolla Province of South Korea, exceeding 50% of subjects. The prevalence of myopia in the school children in Korea is similar to many other countries including People’s Republic of China, Malaysia, and Hong Kong. This may indicate that genetics and educational influences, such as studying and learning, may play a role in the progression of myopia in Korean elementary school children. Keywords: refractive error, elementary school children, visual acuity, myopia, astigmatism

  2. Education influences the association between genetic variants and refractive error: a meta-analysis of five Singapore studies

    Science.gov (United States)

    Fan, Qiao; Wojciechowski, Robert; Kamran Ikram, M.; Cheng, Ching-Yu; Chen, Peng; Zhou, Xin; Pan, Chen-Wei; Khor, Chiea-Chuen; Tai, E-Shyong; Aung, Tin; Wong, Tien-Yin; Teo, Yik-Ying; Saw, Seang-Mei

    2014-01-01

    Refractive error is a complex ocular trait governed by both genetic and environmental factors and possibly their interplay. Thus far, data on the interaction between genetic variants and environmental risk factors for refractive errors are largely lacking. By using findings from recent genome-wide association studies, we investigated whether the main environmental factor, education, modifies the effect of 40 single nucleotide polymorphisms on refractive error among 8461 adults from five studies including ethnic Chinese, Malay and Indian residents of Singapore. Three genetic loci SHISA6-DNAH9, GJD2 and ZMAT4-SFRP1 exhibited a strong association with myopic refractive error in individuals with higher secondary or university education (SHISA6-DNAH9: rs2969180 A allele, β = −0.33 D, P = 3.6 × 10–6; GJD2: rs524952 A allele, β = −0.31 D, P = 1.68 × 10−5; ZMAT4-SFRP1: rs2137277 A allele, β = −0.47 D, P = 1.68 × 10−4), whereas the association at these loci was non-significant or of borderline significance in those with lower secondary education or below (P for interaction: 3.82 × 10−3–4.78 × 10−4). The evidence for interaction was strengthened when combining the genetic effects of these three loci (P for interaction = 4.40 × 10−8), and significant interactions with education were also observed for axial length and myopia. Our study shows that low level of education may attenuate the effect of risk alleles on myopia. These findings further underline the role of gene–environment interactions in the pathophysiology of myopia. PMID:24014484

  3. Knowledge, attitude and associated factors among primary school teachers regarding refractive error in school children in Gondar city, Northwest Ethiopia

    Science.gov (United States)

    2018-01-01

    Introduction Refractive error is an important cause of correctable visual impairment in the worldwide with a global distribution of 1.75% to 20.7% among schoolchildren. Teacher’s knowledge about refractive error play an important role in encouraging students to seek treatment that helps in reducing the burden of visual impairment. Objective To determine knowledge, attitude and associated factors among primary school teachers regarding refractive error in school children in Gondar city. Methods Institution based cross-sectional study was conducted on 565 primary school teachers in Gondar city using pretested and structured self-administered questionnaire. For processing and analysis, SPSS version 20 was used and variables which had a P value of attitude towards refractive error. History of spectacle use [AOR = 2.13 (95% CI: 1.32, 3.43)], history of eye examination [AOR = 1.67 (95% CI: 1.19, 2.34)], training on eye health [AOR = 1.94 (95% CI; 1.09, 3.43)] and 11–20 years of experience [AOR = 2.53 (95% CI: 1.18, 5.43)] were positively associated with knowledge. Whereas being male [AOR = 2.03 (95% CI: 1.37, 3.01)], older age [AOR = 3.05 (95% CI: 1.07, 8.72)], 31–40 years of experience [AOR = 0.23 (95% CI: 0.07, 0.72)], private school type [AOR = 1.76 (95% CI: 1.06, 2.93)] and 5th -8th teaching category [AOR = 1.54 (95% CI: 1.05, 2.24)] were associated with attitude. Conclusion Knowledge and attitude of study subjects were low which needs training of teachers about the refractive error. PMID:29447172

  4. Distribution of Binocular Vision Anomalies and Refractive Errors in Iranian Children With Learning Disabilities

    Directory of Open Access Journals (Sweden)

    Yekta

    2015-11-01

    Full Text Available Background Visual problems in children contribute to learning disorders, which are one of the most influential factors in learning. Objectives The aim of the present study was to determine the prevalence of refractive and binocular vision errors in children with learning disorders. Patients and Methods In this cross-sectional study, 406 children with learning disorders with a mean age of 8.56 ± 2.4 years were evaluated. Examinations included the determination of refractive errors with an auto-refractometer and static retinoscopy, measurement of visual acuity with a Snellen chart, evaluation of ocular deviation, and measurement of stereopsis, amplitude of accommodation, and near point of convergence. Results Of the 406 participants, 319 (78.6% were emmetropic in the right eye, 14.5% had myopia, and 6.9% had hyperopia according to cycloplegic refraction. Astigmatism was detected in 75 (18.5% children. In our study, 89.9% of the children had no deviation, 1.0% had esophoria, and 6.4% had exophoria . In addition, 2.2% of the children had suppression. The near point of convergence ranged from 3 to 18 cm, with a mean of 10.12 ± 3.274 cm. Moreover, 98.5 and 98.0% of the participants achieved complete vision with the best correction in the right and left eye, respectively. The best corrected visual acuity in the right and left eye was achieved in 98.5 and 98.0% of the children, respectively. Conclusions The pattern of visual impairment in learning-impaired children is not much different from that in normal children; however, because these children may not be able to express themselves clearly, lack of correct diagnosis and appropriate treatment has resulted in a marked defect in recognizing visual disorders in these children. Therefore, gaining knowledge of the prevalence of refractive errors in children with learning disorders can be considered the first step in their treatment.

  5. [Refractive errors among schoolchildren in the central region of Togo].

    Science.gov (United States)

    Nonon Saa, K B; Atobian, K; Banla, M; Rédah, T; Maneh, N; Walser, A

    2013-11-01

    Untreated refractive errors represent the main visual impairment in the world but also the easiest to avoid. The goal of this survey is to use clinical and epidemiological data to efficiently plan distribution of corrective glasses in a project supported by the Swiss Red Cross in the central region of Togo. To achieve this goal, 66 primary schools were identified randomly in the catchment area of the project. The teachers at these schools were previously trained to test visual acuity (VA). The schoolchildren referred by these teachers were examined by eye care professionals. The schoolchildren with ametropia (VA≤7/10 in at least one eye) underwent cycloplegic autorefraction. Of a total of 19,252 registered schoolchildren, 13,039 underwent VA testing by the teachers (participation rate=68%). Among them, 366 cases of ametropia were identified (prevalence about 3%). The average age of the schoolchildren examined was 10.7±2.3years, with a sex ratio of 1.06. Autorefraction, which was performed for 37% of the schoolchildren with ametropia allowed them to be classified into three groups: hyperopia (4%), myopia (5%) and astigmatism of all types (91%). Regardless of the type of ametropia, the degree of severity was mild in 88%. The results of this survey have highlighted the importance of the teachers' contribution to eye care education in the struggle against refractive errors within the school environment, as well as helping to efficiently plan actions against ametropia. Copyright © 2013 Elsevier Masson SAS. All rights reserved.

  6. PREVALENCE OF REFRACTIVE ERROR, STRABISMUS AND AMBLYOPIA AMONG CHILDREN WITH NORMAL DEVELOPMENT OR GLOBAL DEVELOPMENTAL DELAY/INTELLECTUAL DISABILITY ATTENDING OPHTHALMOLOGY OPD AT KLES HOSPITAL, BELAGAVI- A RETROSPECTIVE STUDY

    Directory of Open Access Journals (Sweden)

    Smitha K. S

    2017-04-01

    Full Text Available BACKGROUND Global developmental delay/intellectual disability are on a rise in children in the present time. Ocular and visual anomalies are frequently associated with it of which refractive errors are the most frequent. This if goes unnoticed leads to strabismus and amblyopia. MATERIALS AND METHODS This study aims to assess the prevalence of refractive error, strabismus and amblyopia among children with normal development or global developmental delay/intellectual disability attending ophthalmology OPD at KLES Hospital, Belagavi. Case records of all 200 new patients less than or equal to 12 years of age group who attended KLES, Dr. Prabhakar Kore Hospital between January 2015 and December 2015 were retrospectively reviewed. RESULTS The male:female ratio was 1.22:1. Out of the total evaluated 200 cases, 130 cases were with normal development and 70 with GDD/ID. Refractive errors were 85%, whereas the cases of amblyopia was 45.50% and strabismus 39.50%. Amblyopia with refractive error having GDD/ID was stastically significant as compared to amblyopia with refractive error having normal development (p=0.001. CONCLUSION Refractive error was the most common ocular disorder seen. Refractive error with amblyopia is more in children with GDD/ID as compared to normal children. Owing to the high percentage of visual anomalies, ophthalmological referral becomes essential in children with developmental anomalies.

  7. The contributions of near work and outdoor activity to the correlation between siblings in the Collaborative Longitudinal Evaluation of Ethnicity and Refractive Error (CLEERE) Study.

    Science.gov (United States)

    Jones-Jordan, Lisa A; Sinnott, Loraine T; Graham, Nicholas D; Cotter, Susan A; Kleinstein, Robert N; Manny, Ruth E; Mutti, Donald O; Twelker, J Daniel; Zadnik, Karla

    2014-09-09

    We determined the correlation between sibling refractive errors adjusted for shared and unique environmental factors using data from the Collaborative Longitudinal Evaluation of Ethnicity and Refractive Error (CLEERE) Study. Refractive error from subjects' last study visits was used to estimate the intraclass correlation coefficient (ICC) between siblings. The correlation models used environmental factors (diopter-hours and outdoor/sports activity) assessed annually from parents by survey to adjust for shared and unique environmental exposures when estimating the heritability of refractive error (2*ICC). Data from 700 families contributed to the between-sibling correlation for spherical equivalent refractive error. The mean age of the children at the last visit was 13.3 ± 0.90 years. Siblings engaged in similar amounts of near and outdoor activities (correlations ranged from 0.40-0.76). The ICC for spherical equivalent, controlling for age, sex, ethnicity, and site was 0.367 (95% confidence interval [CI] = 0.304, 0.420), with an estimated heritability of no more than 0.733. After controlling for these variables, and near and outdoor/sports activities, the resulting ICC was 0.364 (95% CI = 0.304, 0.420; estimated heritability no more than 0.728, 95% CI = 0.608, 0.850). The ICCs did not differ significantly between male-female and single sex pairs. Adjusting for shared family and unique, child-specific environmental factors only reduced the estimate of refractive error correlation between siblings by 0.5%. Consistent with a lack of association between myopia progression and either near work or outdoor/sports activity, substantial common environmental exposures had little effect on this correlation. Genetic effects appear to have the major role in determining the similarity of refractive error between siblings. Copyright 2014 The Association for Research in Vision and Ophthalmology, Inc.

  8. Influence of refractive error on pupillary dynamics in the normal and mild traumatic brain injury (mTBI populations

    Directory of Open Access Journals (Sweden)

    James Q. Truong

    2018-04-01

    Full Text Available Purpose: There have been several studies investigating static, baseline pupil diameter in visually-normal individuals across refractive error. However, none have assessed the dynamic pupillary light reflex (PLR. In the present study, both static and dynamic pupillary parameters of the PLR were assessed in both the visually-normal (VN and the mild traumatic brain injury (mTBI populations and compared as a function of refractive error. Methods: The VN population comprised 40 adults (22–56 years of age, while the mTBI population comprised 32 adults (21–60 years of age over a range of refractive errors (−9.00 D to +1.25 D. Seven pupillary parameters (baseline static diameter, latency, amplitude, and peak and average constriction and dilation velocities were assessed and compared under four white-light stimulus conditions (dim pulse, dim step, bright pulse, and bright step. The Neuroptics, infrared, DP-2000 binocular pupillometer (30 Hz sampling rate; 0.05 mm resolution was used in the monocular (right eye stimulation mode. Results: For the majority of pupillary parameters and stimulus conditions, a Gaussian distribution best fit the data, with the apex centered in the low myopic range (−2.3 to −4.9D. Responsivity was reduced to either side of the apex. Conclusions: Over a range of dynamic and static pupillary parameters, the PLR was influenced by refractive error in both populations. In cases of high refractive error, the PLR parameters may need to be compensated for this factor for proper categorization and diagnosis. Resumen: Objetivo: Existen diversos estudios que han investigado el diámetro pupilar estático y basal en individuos con visión normal en todo el espectro de errores refractivos. Sin embargo, ninguno de ellos ha evaluado el reflejo dinámico pupilar a la luz (RPL. En el presente estudio, se evaluaron tanto los parámetros pupilares estáticos como los dinámicos en poblaciones con visión normal (VN y en las afectadas

  9. Peripheral refraction in normal infant rhesus monkeys

    Science.gov (United States)

    Hung, Li-Fang; Ramamirtham, Ramkumar; Huang, Juan; Qiao-Grider, Ying; Smith, Earl L.

    2008-01-01

    Purpose To characterize peripheral refractions in infant monkeys. Methods Cross-sectional data for horizontal refractions were obtained from 58 normal rhesus monkeys at 3 weeks of age. Longitudinal data were obtained for both the vertical and horizontal meridians from 17 monkeys. Refractive errors were measured by retinoscopy along the pupillary axis and at eccentricities of 15, 30, and 45 degrees. Axial dimensions and corneal power were measured by ultrasonography and keratometry, respectively. Results In infant monkeys, the degree of radial astigmatism increased symmetrically with eccentricity in all meridians. There were, however, initial nasal-temporal and superior-inferior asymmetries in the spherical-equivalent refractive errors. Specifically, the refractions in the temporal and superior fields were similar to the central ametropia, but the refractions in the nasal and inferior fields were more myopic than the central ametropia and the relative nasal field myopia increased with the degree of central hyperopia. With age, the degree of radial astigmatism decreased in all meridians and the refractions became more symmetrical along both the horizontal and vertical meridians; small degrees of relative myopia were evident in all fields. Conclusions As in adult humans, refractive error varied as a function of eccentricity in infant monkeys and the pattern of peripheral refraction varied with the central refractive error. With age, emmetropization occurred for both central and peripheral refractive errors resulting in similar refractions across the central 45 degrees of the visual field, which may reflect the actions of vision-dependent, growth-control mechanisms operating over a wide area of the posterior globe. PMID:18487366

  10. Prevalence of Visual Impairment and Refractive Errors in Children of South Sinai, Egypt.

    Science.gov (United States)

    Yamamah, Gamal Abdel Naser; Talaat Abdel Alim, Ahmed Ahmed; Mostafa, Yehia Salah El Din; Ahmed, Rania Ahmed Abdel Salam; Mohammed, Asmaa Mahmoud; Mahmoud, Asmaa Mohammed

    2015-01-01

    To assess the prevalence and causes of visual impairment in children of South Sinai, and to evaluate outcomes of rehabilitation programs. Population-based, cross-sectional analysis of 2070 healthy school children screened for visual impairment from 2009 through 2010 in cities of South Sinai and their surrounding Bedouin settlements. Visual acuity (VA) was tested using Snellen charts followed by cycloplegic autorefractometry for cases with presenting VA ≤ 6/9. Appropriate eyeglasses were prescribed and VA re-evaluated. This study included 1047 boys and 1023 girls, mean age 10.7 ± 3.1 years. Visual impairment (uncorrected VA ≤ 6/9) was detected in 29.4% of children, while 2.0% had moderate-severe visual impairment (uncorrected VA ≤ 6/24). There were statistically significant differences in prevalence of visual impairment between the studied cities (p visual impairment was significantly higher among girls (p children showed significantly lower prevalences of visual impairment. Only age was a reliable predictor of visual impairment (odds ratio 0.94, p children who received spectacles (p children had some form of visual impairment, 90.32% of which comprised refractive errors (mainly astigmatism) which were significantly corrected with eyeglasses. VA screening and correction of refractive errors are of the utmost importance for ensuring better visual outcomes and improved school performance.

  11. Müller glia-derived PRSS56 is required to sustain ocular axial growth and prevent refractive error.

    Science.gov (United States)

    Paylakhi, Seyyedhassan; Labelle-Dumais, Cassandre; Tolman, Nicholas G; Sellarole, Michael A; Seymens, Yusef; Saunders, Joseph; Lakosha, Hesham; deVries, Wilhelmine N; Orr, Andrew C; Topilko, Piotr; John, Simon Wm; Nair, K Saidas

    2018-03-01

    A mismatch between optical power and ocular axial length results in refractive errors. Uncorrected refractive errors constitute the most common cause of vision loss and second leading cause of blindness worldwide. Although the retina is known to play a critical role in regulating ocular growth and refractive development, the precise factors and mechanisms involved are poorly defined. We have previously identified a role for the secreted serine protease PRSS56 in ocular size determination and PRSS56 variants have been implicated in the etiology of both hyperopia and myopia, highlighting its importance in refractive development. Here, we use a combination of genetic mouse models to demonstrate that Prss56 mutations leading to reduced ocular size and hyperopia act via a loss of function mechanism. Using a conditional gene targeting strategy, we show that PRSS56 derived from Müller glia contributes to ocular growth, implicating a new retinal cell type in ocular size determination. Importantly, we demonstrate that persistent activity of PRSS56 is required during distinct developmental stages spanning the pre- and post-eye opening periods to ensure optimal ocular growth. Thus, our mouse data provide evidence for the existence of a molecule contributing to both the prenatal and postnatal stages of human ocular growth. Finally, we demonstrate that genetic inactivation of Prss56 rescues axial elongation in a mouse model of myopia caused by a null mutation in Egr1. Overall, our findings identify PRSS56 as a potential therapeutic target for modulating ocular growth aimed at preventing or slowing down myopia, which is reaching epidemic proportions.

  12. Müller glia-derived PRSS56 is required to sustain ocular axial growth and prevent refractive error.

    Directory of Open Access Journals (Sweden)

    Seyyedhassan Paylakhi

    2018-03-01

    Full Text Available A mismatch between optical power and ocular axial length results in refractive errors. Uncorrected refractive errors constitute the most common cause of vision loss and second leading cause of blindness worldwide. Although the retina is known to play a critical role in regulating ocular growth and refractive development, the precise factors and mechanisms involved are poorly defined. We have previously identified a role for the secreted serine protease PRSS56 in ocular size determination and PRSS56 variants have been implicated in the etiology of both hyperopia and myopia, highlighting its importance in refractive development. Here, we use a combination of genetic mouse models to demonstrate that Prss56 mutations leading to reduced ocular size and hyperopia act via a loss of function mechanism. Using a conditional gene targeting strategy, we show that PRSS56 derived from Müller glia contributes to ocular growth, implicating a new retinal cell type in ocular size determination. Importantly, we demonstrate that persistent activity of PRSS56 is required during distinct developmental stages spanning the pre- and post-eye opening periods to ensure optimal ocular growth. Thus, our mouse data provide evidence for the existence of a molecule contributing to both the prenatal and postnatal stages of human ocular growth. Finally, we demonstrate that genetic inactivation of Prss56 rescues axial elongation in a mouse model of myopia caused by a null mutation in Egr1. Overall, our findings identify PRSS56 as a potential therapeutic target for modulating ocular growth aimed at preventing or slowing down myopia, which is reaching epidemic proportions.

  13. Müller glia-derived PRSS56 is required to sustain ocular axial growth and prevent refractive error

    Science.gov (United States)

    Tolman, Nicholas G; Sellarole, Michael A.; Saunders, Joseph; Lakosha, Hesham; Topilko, Piotr; John, Simon WM.

    2018-01-01

    A mismatch between optical power and ocular axial length results in refractive errors. Uncorrected refractive errors constitute the most common cause of vision loss and second leading cause of blindness worldwide. Although the retina is known to play a critical role in regulating ocular growth and refractive development, the precise factors and mechanisms involved are poorly defined. We have previously identified a role for the secreted serine protease PRSS56 in ocular size determination and PRSS56 variants have been implicated in the etiology of both hyperopia and myopia, highlighting its importance in refractive development. Here, we use a combination of genetic mouse models to demonstrate that Prss56 mutations leading to reduced ocular size and hyperopia act via a loss of function mechanism. Using a conditional gene targeting strategy, we show that PRSS56 derived from Müller glia contributes to ocular growth, implicating a new retinal cell type in ocular size determination. Importantly, we demonstrate that persistent activity of PRSS56 is required during distinct developmental stages spanning the pre- and post-eye opening periods to ensure optimal ocular growth. Thus, our mouse data provide evidence for the existence of a molecule contributing to both the prenatal and postnatal stages of human ocular growth. Finally, we demonstrate that genetic inactivation of Prss56 rescues axial elongation in a mouse model of myopia caused by a null mutation in Egr1. Overall, our findings identify PRSS56 as a potential therapeutic target for modulating ocular growth aimed at preventing or slowing down myopia, which is reaching epidemic proportions. PMID:29529029

  14. Amplitude of Accommodation and its Relation to Refractive Errors

    Directory of Open Access Journals (Sweden)

    Abraham Lekha

    2005-01-01

    Full Text Available Aims: To evaluate the relationship between amplitude of accommodation and refractive errors in the peri-presbyopic age group. Materials and Methods: Three hundred and sixteen right eyes of 316 consecutive patients in the age group 35-50 years who attended our outpatient clinic were studied. Emmetropes, hypermetropes and myopes with best-corrected visual acuity of 6/6 J1 in both eyes were included. The amplitude of accommodation (AA was calculated by measuring the near point of accommodation (NPA. In patients with more than ± 2 diopter sphere correction for distance, the NPA was also measured using appropriate soft contact lenses. Results: There was a statistically significant difference in AA between myopes and hypermetropes ( P P P P P P >0.5. Conclusion: Our study showed higher amplitude of accommodation among myopes between 35 and 44 years compared to emmetropes and hypermetropes

  15. Visual disability, visual function, and myopia among rural chinese secondary school children: the Xichang Pediatric Refractive Error Study (X-PRES)--report 1.

    Science.gov (United States)

    Congdon, Nathan; Wang, Yunfei; Song, Yue; Choi, Kai; Zhang, Mingzhi; Zhou, Zhongxia; Xie, Zhenling; Li, Liping; Liu, Xueyu; Sharma, Abhishek; Wu, Bin; Lam, Dennis S C

    2008-07-01

    To evaluate visual acuity, visual function, and prevalence of refractive error among Chinese secondary-school children in a cross-sectional school-based study. Uncorrected, presenting, and best corrected visual acuity, cycloplegic autorefraction with refinement, and self-reported visual function were assessed in a random, cluster sample of rural secondary school students in Xichang, China. Among the 1892 subjects (97.3% of the consenting children, 84.7% of the total sample), mean age was 14.7 +/- 0.8 years, 51.2% were female, and 26.4% were wearing glasses. The proportion of children with uncorrected, presenting, and corrected visual disability (visual disability when tested without correction, 98.7% was due to refractive error, while only 53.8% (414/770) of these children had appropriate correction. The girls had significantly (P visual disability and myopia visual function (ANOVA trend test, P Visual disability in this population was common, highly correctable, and frequently uncorrected. The impact of refractive error on self-reported visual function was significant. Strategies and studies to understand and remove barriers to spectacle wear are needed.

  16. Genome-wide meta-analyses of multiancestry cohorts identify multiple new susceptibility loci for refractive error and myopia

    NARCIS (Netherlands)

    Verhoeven, Virginie J. M.; Hysi, Pirro G.; Wojciechowski, Robert; Fan, Qiao; Guggenheim, Jeremy A.; Höhn, René; Macgregor, Stuart; Hewitt, Alex W.; Nag, Abhishek; Cheng, Ching-Yu; Yonova-Doing, Ekaterina; Zhou, Xin; Ikram, M. Kamran; Buitendijk, Gabriëlle H. S.; McMahon, George; Kemp, John P.; Pourcain, Beate St; Simpson, Claire L.; Mäkelä, Kari-Matti; Lehtimäki, Terho; Kähönen, Mika; Paterson, Andrew D.; Hosseini, S. Mohsen; Wong, Hoi Suen; Xu, Liang; Jonas, Jost B.; Pärssinen, Olavi; Wedenoja, Juho; Yip, Shea Ping; Ho, Daniel W. H.; Pang, Chi Pui; Chen, Li Jia; Burdon, Kathryn P.; Craig, Jamie E.; Klein, Barbara E. K.; Klein, Ronald; Haller, Toomas; Metspalu, Andres; Khor, Chiea-Chuen; Tai, E.-Shyong; Aung, Tin; Vithana, Eranga; Tay, Wan-Ting; Barathi, Veluchamy A.; Chen, Peng; Li, Ruoying; Liao, Jiemin; Zheng, Yingfeng; Bergen, Arthur A. B.; Chen, Wei

    2013-01-01

    Refractive error is the most common eye disorder worldwide and is a prominent cause of blindness. Myopia affects over 30% of Western populations and up to 80% of Asians. The CREAM consortium conducted genome-wide meta-analyses, including 37,382 individuals from 27 studies of European ancestry and

  17. Can the Bruckner test be used as a rapid screening test to detect significant refractive errors in children?

    Directory of Open Access Journals (Sweden)

    Kothari Mihir

    2007-01-01

    Full Text Available Purpose: To assess the suitability of Brückner test as a screening test to detect significant refractive errors in children. Materials and Methods: A pediatric ophthalmologist prospectively observed the size and location of pupillary crescent on Brückner test as hyperopic, myopic or astigmatic. This was compared with the cycloplegic refraction. Detailed ophthalmic examination was done for all. Sensitivity, specificity, positive predictive value and negative predictive value of Brückner test were determined for the defined cutoff levels of ametropia. Results: Ninety-six subjects were examined. Mean age was 8.6 years (range 1 to 16 years. Brückner test could be completed for all; the time taken to complete this test was 10 seconds per subject. The ophthalmologist identified 131 eyes as ametropic, 61 as emmetropic. The Brückner test had sensitivity 91%, specificity 72.8%, positive predictive value 85.5% and negative predictive value 83.6%. Of 10 false negatives four had compound hypermetropic astigmatism and three had myopia. Conclusions: Brückner test can be used to rapidly screen the children for significant refractive errors. The potential benefits from such use may be maximized if programs use the test with lower crescent measurement cutoffs, a crescent measurement ruler and a distance fixation target.

  18. Non-topography-guided PRK combined with CXL for the correction of refractive errors in patients with early stage keratoconus.

    Science.gov (United States)

    Fadlallah, Ali; Dirani, Ali; Chelala, Elias; Antonios, Rafic; Cherfan, George; Jarade, Elias

    2014-10-01

    To evaluate the safety and clinical outcome of combined non-topography-guided photorefractive keratectomy (PRK) and corneal collagen cross-linking (CXL) for the treatment of mild refractive errors in patients with early stage keratoconus. A retrospective, nonrandomized study of patients with early stage keratoconus (stage 1 or 2) who underwent simultaneous non-topography-guided PRK and CXL. All patients had at least 2 years of follow-up. Data were collected preoperatively and postoperatively at the 6-month, 1-year, and 2-year follow-up visit after combined non-topography-guided PRK and CXL. Seventy-nine patients (140 eyes) were included in the study. Combined non-topography-guided PRK and CXL induced a significant improvement in both visual acuity and refraction. Uncorrected distance visual acuity significantly improved from 0.39 ± 0.22 logMAR before combined non-topography-guided PRK and CXL to 0.12 ± 0.14 logMAR at the last follow-up visit (P PRK and CXL (P PRK and CXL is an effective and safe option for correcting mild refractive error and improving visual acuity in patients with early stable keratoconus. Copyright 2014, SLACK Incorporated.

  19. Optical 'dampening' of the refractive error to axial length ratio: implications for outcome measures in myopia control studies.

    Science.gov (United States)

    Cruickshank, Fiona E; Logan, Nicola S

    2018-05-01

    To gauge the extent to which differences in the refractive error axial length relationship predicted by geometrical optics are observed in actual refractive/biometric data. This study is a retrospective analysis of existing data. Right eye refractive error [RX] and axial length [AXL] data were collected on 343 6-to-7-year-old children [mean 7.18 years (S.D. 0.35)], 294 12-to-13-year-old children [mean 13.12 years (S.D. 0.32)] and 123 young adults aged 18-to-25-years [mean 20.56 years (S.D. 1.91)]. Distance RX was measured with the Shin-Nippon NVision-K 5001 infrared open-field autorefractor. Child participants were cyclopleged prior to data collection (1% Cyclopentolate Hydrochloride). Myopia was defined as a mean spherical equivalent [MSE] ≤-0.50 D. Axial length was measured using the Zeiss IOLMaster 500. Optical modelling was based on ray tracing and manipulation of parameters of a Gullstrand reduced model eye. There was a myopic shift in mean MSE with age (6-7 years +0.87 D, 12-13 years -0.06 D and 18-25 years -1.41 D), associated with an increase in mean AXL (6-7 years 22.70 mm, 12-13 years 23.49 mm and 18-25 years 23.98 mm). There was a significant negative correlation between MSE and AXL for all age groups (all p theory predicts that there will be a reduction in the RX: AXL ratio with longer eyes. The participant data although adhering to this theory show a reduced effect, with eyes with longer axial lengths having a lower refractive error to axial length ratio than predicted by model eye calculations. We propose that in myopia control intervention studies when comparing efficacy, consideration should be given to the dampening effect seen with a longer eye. © 2018 The Authors. Ophthalmic and Physiological Optics published by John Wiley & Sons Ltd on behalf of College of Optometrists.

  20. The KwaZulu-Natal Child Eye Care Programme: Delivering refractive error services to primary school learners

    Directory of Open Access Journals (Sweden)

    Y. I. Mahraj

    2011-12-01

    sion screeners screened 239 606 primary school children from February 2007 to May 2008. Seven percent (15 944 of the children failed the vision screening and were referred for optometric assessments. Of the 15 944 children that failed the vision screening, 10 707 children were examined by optometrists and 1083 were found to have a refractive error and were therefore supplied with spectacles. The study indicates that a short-term programme to address a backlog of services can reach many underserved children. This programme identified many challenges of implementing a vision screening programme such as poor uptake of refractive services by learners in the absence of an appropriate referral system and high attrition of trained vision screeners. (S Afr Optom 2011 70(2 61-68

  1. Relation of anthropometric measurements to ocular biometric changes and refractive error in children with thalassemia.

    Science.gov (United States)

    Elkitkat, Rania S; El-Shazly, Amany A; Ebeid, Weam M; Deghedy, Marwa R

    2018-03-01

    To evaluate and correlate anthropometric, biometric, and refractive error changes in thalassemia major (TM). One hundred children with TM and another hundred healthy controls were recruited. Height, weight, body mass index (BMI), and occipitofrontal circumference (OFC) were the anthropometric parameters recorded. Full ophthalmologic examination was performed, including best-corrected visual acuity, cycloplegic refraction, slit-lamp examination, Goldmann applanation tonometry, indirect ophthalmoscopy, keratometry (K readings), and ocular biometry. Compared to controls, children with TM were shorter and lighter, with a smaller BMI (pbiometric data, patients with thalassemia had steeper mean K readings (p = 0.03), shorter axial length (AXL) (p = 0.005), shorter vitreous chamber depth (pbiometric changes (steeper corneas and thicker lenses) to reach emmetropization, with an exaggerated response and subsequent myopic shift. However, growth retardation is not directly related to ocular growth changes, myopic shift, or variations in biometric parameters.

  2. Nine Loci for Ocular Axial Length Identified through Genome-wide Association Studies, Including Shared Loci with Refractive Error

    Science.gov (United States)

    Cheng, Ching-Yu; Schache, Maria; Ikram, M. Kamran; Young, Terri L.; Guggenheim, Jeremy A.; Vitart, Veronique; MacGregor, Stuart; Verhoeven, Virginie J.M.; Barathi, Veluchamy A.; Liao, Jiemin; Hysi, Pirro G.; Bailey-Wilson, Joan E.; St. Pourcain, Beate; Kemp, John P.; McMahon, George; Timpson, Nicholas J.; Evans, David M.; Montgomery, Grant W.; Mishra, Aniket; Wang, Ya Xing; Wang, Jie Jin; Rochtchina, Elena; Polasek, Ozren; Wright, Alan F.; Amin, Najaf; van Leeuwen, Elisabeth M.; Wilson, James F.; Pennell, Craig E.; van Duijn, Cornelia M.; de Jong, Paulus T.V.M.; Vingerling, Johannes R.; Zhou, Xin; Chen, Peng; Li, Ruoying; Tay, Wan-Ting; Zheng, Yingfeng; Chew, Merwyn; Rahi, Jugnoo S.; Hysi, Pirro G.; Yoshimura, Nagahisa; Yamashiro, Kenji; Miyake, Masahiro; Delcourt, Cécile; Maubaret, Cecilia; Williams, Cathy; Guggenheim, Jeremy A.; Northstone, Kate; Ring, Susan M.; Davey-Smith, George; Craig, Jamie E.; Burdon, Kathryn P.; Fogarty, Rhys D.; Iyengar, Sudha K.; Igo, Robert P.; Chew, Emily; Janmahasathian, Sarayut; Iyengar, Sudha K.; Igo, Robert P.; Chew, Emily; Janmahasathian, Sarayut; Stambolian, Dwight; Wilson, Joan E. Bailey; MacGregor, Stuart; Lu, Yi; Jonas, Jost B.; Xu, Liang; Saw, Seang-Mei; Baird, Paul N.; Rochtchina, Elena; Mitchell, Paul; Wang, Jie Jin; Jonas, Jost B.; Nangia, Vinay; Hayward, Caroline; Wright, Alan F.; Vitart, Veronique; Polasek, Ozren; Campbell, Harry; Vitart, Veronique; Rudan, Igor; Vatavuk, Zoran; Vitart, Veronique; Paterson, Andrew D.; Hosseini, S. Mohsen; Iyengar, Sudha K.; Igo, Robert P.; Fondran, Jeremy R.; Young, Terri L.; Feng, Sheng; Verhoeven, Virginie J.M.; Klaver, Caroline C.; van Duijn, Cornelia M.; Metspalu, Andres; Haller, Toomas; Mihailov, Evelin; Pärssinen, Olavi; Wedenoja, Juho; Wilson, Joan E. Bailey; Wojciechowski, Robert; Baird, Paul N.; Schache, Maria; Pfeiffer, Norbert; Höhn, René; Pang, Chi Pui; Chen, Peng; Meitinger, Thomas; Oexle, Konrad; Wegner, Aharon; Yoshimura, Nagahisa; Yamashiro, Kenji; Miyake, Masahiro; Pärssinen, Olavi; Yip, Shea Ping; Ho, Daniel W.H.; Pirastu, Mario; Murgia, Federico; Portas, Laura; Biino, Genevra; Wilson, James F.; Fleck, Brian; Vitart, Veronique; Stambolian, Dwight; Wilson, Joan E. Bailey; Hewitt, Alex W.; Ang, Wei; Verhoeven, Virginie J.M.; Klaver, Caroline C.; van Duijn, Cornelia M.; Saw, Seang-Mei; Wong, Tien-Yin; Teo, Yik-Ying; Fan, Qiao; Cheng, Ching-Yu; Zhou, Xin; Ikram, M. Kamran; Saw, Seang-Mei; Teo, Yik-Ying; Fan, Qiao; Cheng, Ching-Yu; Zhou, Xin; Ikram, M. Kamran; Saw, Seang-Mei; Wong, Tien-Yin; Teo, Yik-Ying; Fan, Qiao; Cheng, Ching-Yu; Zhou, Xin; Ikram, M. Kamran; Saw, Seang-Mei; Wong, Tien-Yin; Teo, Yik-Ying; Fan, Qiao; Cheng, Ching-Yu; Zhou, Xin; Ikram, M. Kamran; Saw, Seang-Mei; Tai, E-Shyong; Teo, Yik-Ying; Fan, Qiao; Cheng, Ching-Yu; Zhou, Xin; Ikram, M. Kamran; Saw, Seang-Mei; Teo, Yik-Ying; Fan, Qiao; Cheng, Ching-Yu; Zhou, Xin; Ikram, M. Kamran; Mackey, David A.; MacGregor, Stuart; Hammond, Christopher J.; Hysi, Pirro G.; Deangelis, Margaret M.; Morrison, Margaux; Zhou, Xiangtian; Chen, Wei; Paterson, Andrew D.; Hosseini, S. Mohsen; Mizuki, Nobuhisa; Meguro, Akira; Lehtimäki, Terho; Mäkelä, Kari-Matti; Raitakari, Olli; Kähönen, Mika; Burdon, Kathryn P.; Craig, Jamie E.; Iyengar, Sudha K.; Igo, Robert P.; Lass, Jonathan H.; Reinhart, William; Belin, Michael W.; Schultze, Robert L.; Morason, Todd; Sugar, Alan; Mian, Shahzad; Soong, Hunson Kaz; Colby, Kathryn; Jurkunas, Ula; Yee, Richard; Vital, Mark; Alfonso, Eduardo; Karp, Carol; Lee, Yunhee; Yoo, Sonia; Hammersmith, Kristin; Cohen, Elisabeth; Laibson, Peter; Rapuano, Christopher; Ayres, Brandon; Croasdale, Christopher; Caudill, James; Patel, Sanjay; Baratz, Keith; Bourne, William; Maguire, Leo; Sugar, Joel; Tu, Elmer; Djalilian, Ali; Mootha, Vinod; McCulley, James; Bowman, Wayne; Cavanaugh, H. Dwight; Verity, Steven; Verdier, David; Renucci, Ann; Oliva, Matt; Rotkis, Walter; Hardten, David R.; Fahmy, Ahmad; Brown, Marlene; Reeves, Sherman; Davis, Elizabeth A.; Lindstrom, Richard; Hauswirth, Scott; Hamilton, Stephen; Lee, W. Barry; Price, Francis; Price, Marianne; Kelly, Kathleen; Peters, Faye; Shaughnessy, Michael; Steinemann, Thomas; Dupps, B.J.; Meisler, David M.; Mifflin, Mark; Olson, Randal; Aldave, Anthony; Holland, Gary; Mondino, Bartly J.; Rosenwasser, George; Gorovoy, Mark; Dunn, Steven P.; Heidemann, David G.; Terry, Mark; Shamie, Neda; Rosenfeld, Steven I.; Suedekum, Brandon; Hwang, David; Stone, Donald; Chodosh, James; Galentine, Paul G.; Bardenstein, David; Goddard, Katrina; Chin, Hemin; Mannis, Mark; Varma, Rohit; Borecki, Ingrid; Chew, Emily Y.; Haller, Toomas; Mihailov, Evelin; Metspalu, Andres; Wedenoja, Juho; Simpson, Claire L.; Wojciechowski, Robert; Höhn, René; Mirshahi, Alireza; Zeller, Tanja; Pfeiffer, Norbert; Lackner, Karl J.; Donnelly, Peter; Barroso, Ines; Blackwell, Jenefer M.; Bramon, Elvira; Brown, Matthew A.; Casas, Juan P.; Corvin, Aiden; Deloukas, Panos; Duncanson, Audrey; Jankowski, Janusz; Markus, Hugh S.; Mathew, Christopher G.; Palmer, Colin N.A.; Plomin, Robert; Rautanen, Anna; Sawcer, Stephen J.; Trembath, Richard C.; Viswanathan, Ananth C.; Wood, Nicholas W.; Spencer, Chris C.A.; Band, Gavin; Bellenguez, Céline; Freeman, Colin; Hellenthal, Garrett; Giannoulatou, Eleni; Pirinen, Matti; Pearson, Richard; Strange, Amy; Su, Zhan; Vukcevic, Damjan; Donnelly, Peter; Langford, Cordelia; Hunt, Sarah E.; Edkins, Sarah; Gwilliam, Rhian; Blackburn, Hannah; Bumpstead, Suzannah J.; Dronov, Serge; Gillman, Matthew; Gray, Emma; Hammond, Naomi; Jayakumar, Alagurevathi; McCann, Owen T.; Liddle, Jennifer; Potter, Simon C.; Ravindrarajah, Radhi; Ricketts, Michelle; Waller, Matthew; Weston, Paul; Widaa, Sara; Whittaker, Pamela; Barroso, Ines; Deloukas, Panos; Mathew, Christopher G.; Blackwell, Jenefer M.; Brown, Matthew A.; Corvin, Aiden; Spencer, Chris C.A.; Bettecken, Thomas; Meitinger, Thomas; Oexle, Konrad; Pirastu, Mario; Portas, Laura; Nag, Abhishek; Williams, Katie M.; Yonova-Doing, Ekaterina; Klein, Ronald; Klein, Barbara E.; Hosseini, S. Mohsen; Paterson, Andrew D.; Genuth, S.; Nathan, D.M.; Zinman, B.; Crofford, O.; Crandall, J.; Reid, M.; Brown-Friday, J.; Engel, S.; Sheindlin, J.; Martinez, H.; Shamoon, H.; Engel, H.; Phillips, M.; Gubitosi-Klug, R.; Mayer, L.; Pendegast, S.; Zegarra, H.; Miller, D.; Singerman, L.; Smith-Brewer, S.; Novak, M.; Quin, J.; Dahms, W.; Genuth, Saul; Palmert, M.; Brillon, D.; Lackaye, M.E.; Kiss, S.; Chan, R.; Reppucci, V.; Lee, T.; Heinemann, M.; Whitehouse, F.; Kruger, D.; Jones, J.K.; McLellan, M.; Carey, J.D.; Angus, E.; Thomas, A.; Galprin, A.; Bergenstal, R.; Johnson, M.; Spencer, M.; Morgan, K.; Etzwiler, D.; Kendall, D.; Aiello, Lloyd Paul; Golden, E.; Jacobson, A.; Beaser, R.; Ganda, O.; Hamdy, O.; Wolpert, H.; Sharuk, G.; Arrigg, P.; Schlossman, D.; Rosenzwieg, J.; Rand, L.; Nathan, D.M.; Larkin, M.; Ong, M.; Godine, J.; Cagliero, E.; Lou, P.; Folino, K.; Fritz, S.; Crowell, S.; Hansen, K.; Gauthier-Kelly, C.; Service, J.; Ziegler, G.; Luttrell, L.; Caulder, S.; Lopes-Virella, M.; Colwell, J.; Soule, J.; Fernandes, J.; Hermayer, K.; Kwon, S.; Brabham, M.; Blevins, A.; Parker, J.; Lee, D.; Patel, N.; Pittman, C.; Lindsey, P.; Bracey, M.; Lee, K.; Nutaitis, M.; Farr, A.; Elsing, S.; Thompson, T.; Selby, J.; Lyons, T.; Yacoub-Wasef, S.; Szpiech, M.; Wood, D.; Mayfield, R.; Molitch, M.; Schaefer, B.; Jampol, L.; Lyon, A.; Gill, M.; Strugula, Z.; Kaminski, L.; Mirza, R.; Simjanoski, E.; Ryan, D.; Kolterman, O.; Lorenzi, G.; Goldbaum, M.; Sivitz, W.; Bayless, M.; Counts, D.; Johnsonbaugh, S.; Hebdon, M.; Salemi, P.; Liss, R.; Donner, T.; Gordon, J.; Hemady, R.; Kowarski, A.; Ostrowski, D.; Steidl, S.; Jones, B.; Herman, W.H.; Martin, C.L.; Pop-Busui, R.; Sarma, A.; Albers, J.; Feldman, E.; Kim, K.; Elner, S.; Comer, G.; Gardner, T.; Hackel, R.; Prusak, R.; Goings, L.; Smith, A.; Gothrup, J.; Titus, P.; Lee, J.; Brandle, M.; Prosser, L.; Greene, D.A.; Stevens, M.J.; Vine, A.K.; Bantle, J.; Wimmergren, N.; Cochrane, A.; Olsen, T.; Steuer, E.; Rath, P.; Rogness, B.; Hainsworth, D.; Goldstein, D.; Hitt, S.; Giangiacomo, J.; Schade, D.S.; Canady, J.L.; Chapin, J.E.; Ketai, L.H.; Braunstein, C.S.; Bourne, P.A.; Schwartz, S.; Brucker, A.; Maschak-Carey, B.J.; Baker, L.; Orchard, T.; Silvers, N.; Ryan, C.; Songer, T.; Doft, B.; Olson, S.; Bergren, R.L.; Lobes, L.; Rath, P. Paczan; Becker, D.; Rubinstein, D.; Conrad, P.W.; Yalamanchi, S.; Drash, A.; Morrison, A.; Bernal, M.L.; Vaccaro-Kish, J.; Malone, J.; Pavan, P.R.; Grove, N.; Iyer, M.N.; Burrows, A.F.; Tanaka, E.A.; Gstalder, R.; Dagogo-Jack, S.; Wigley, C.; Ricks, H.; Kitabchi, A.; Murphy, M.B.; Moser, S.; Meyer, D.; Iannacone, A.; Chaum, E.; Yoser, S.; Bryer-Ash, M.; Schussler, S.; Lambeth, H.; Raskin, P.; Strowig, S.; Zinman, B.; Barnie, A.; Devenyi, R.; Mandelcorn, M.; Brent, M.; Rogers, S.; Gordon, A.; Palmer, J.; Catton, S.; Brunzell, J.; Wessells, H.; de Boer, I.H.; Hokanson, J.; Purnell, J.; Ginsberg, J.; Kinyoun, J.; Deeb, S.; Weiss, M.; Meekins, G.; Distad, J.; Van Ottingham, L.; Dupre, J.; Harth, J.; Nicolle, D.; Driscoll, M.; Mahon, J.; Canny, C.; May, M.; Lipps, J.; Agarwal, A.; Adkins, T.; Survant, L.; Pate, R.L.; Munn, G.E.; Lorenz, R.; Feman, S.; White, N.; Levandoski, L.; Boniuk, I.; Grand, G.; Thomas, M.; Joseph, D.D.; Blinder, K.; Shah, G.; Boniuk; Burgess; Santiago, J.; Tamborlane, W.; Gatcomb, P.; Stoessel, K.; Taylor, K.; Goldstein, J.; Novella, S.; Mojibian, H.; Cornfeld, D.; Lima, J.; Bluemke, D.; Turkbey, E.; van der Geest, R.J.; Liu, C.; Malayeri, A.; Jain, A.; Miao, C.; Chahal, H.; Jarboe, R.; Maynard, J.; Gubitosi-Klug, R.; Quin, J.; Gaston, P.; Palmert, M.; Trail, R.; Dahms, W.; Lachin, J.; Cleary, P.; Backlund, J.; Sun, W.; Braffett, B.; Klumpp, K.; Chan, K.; Diminick, L.; Rosenberg, D.; Petty, B.; Determan, A.; Kenny, D.; Rutledge, B.; Younes, Naji; Dews, L.; Hawkins, M.; Cowie, C.; Fradkin, J.; Siebert, C.; Eastman, R.; Danis, R.; Gangaputra, S.; Neill, S.; Davis, M.; Hubbard, L.; Wabers, H.; Burger, M.; Dingledine, J.; Gama, V.; Sussman, R.; Steffes, M.; Bucksa, J.; Nowicki, M.; Chavers, B.; O’Leary, D.; Polak, J.; Harrington, A.; Funk, L.; Crow, R.; Gloeb, B.; Thomas, S.; O’Donnell, C.; Soliman, E.; Zhang, Z.M.; Prineas, R.; Campbell, C.; Ryan, C.; Sandstrom, D.; Williams, T.; Geckle, M.; Cupelli, E.; Thoma, F.; Burzuk, B.; Woodfill, T.; Low, P.; Sommer, C.; Nickander, K.; Budoff, M.; Detrano, R.; Wong, N.; Fox, M.; Kim, L.; Oudiz, R.; Weir, G.; Espeland, M.; Manolio, T.; Rand, L.; Singer, D.; Stern, M.; Boulton, A.E.; Clark, C.; D’Agostino, R.; Lopes-Virella, M.; Garvey, W.T.; Lyons, T.J.; Jenkins, A.; Virella, G.; Jaffa, A.; Carter, Rickey; Lackland, D.; Brabham, M.; McGee, D.; Zheng, D.; Mayfield, R.K.; Boright, A.; Bull, S.; Sun, L.; Scherer, S.; Zinman, B.; Natarajan, R.; Miao, F.; Zhang, L.; Chen;, Z.; Nathan, D.M.; Makela, Kari-Matti; Lehtimaki, Terho; Kahonen, Mika; Raitakari, Olli; Yoshimura, Nagahisa; Matsuda, Fumihiko; Chen, Li Jia; Pang, Chi Pui; Yip, Shea Ping; Yap, Maurice K.H.; Meguro, Akira; Mizuki, Nobuhisa; Inoko, Hidetoshi; Foster, Paul J.; Zhao, Jing Hua; Vithana, Eranga; Tai, E-Shyong; Fan, Qiao; Xu, Liang; Campbell, Harry; Fleck, Brian; Rudan, Igor; Aung, Tin; Hofman, Albert; Uitterlinden, André G.; Bencic, Goran; Khor, Chiea-Chuen; Forward, Hannah; Pärssinen, Olavi; Mitchell, Paul; Rivadeneira, Fernando; Hewitt, Alex W.; Williams, Cathy; Oostra, Ben A.; Teo, Yik-Ying; Hammond, Christopher J.; Stambolian, Dwight; Mackey, David A.; Klaver, Caroline C.W.; Wong, Tien-Yin; Saw, Seang-Mei; Baird, Paul N.

    2013-01-01

    Refractive errors are common eye disorders of public health importance worldwide. Ocular axial length (AL) is the major determinant of refraction and thus of myopia and hyperopia. We conducted a meta-analysis of genome-wide association studies for AL, combining 12,531 Europeans and 8,216 Asians. We identified eight genome-wide significant loci for AL (RSPO1, C3orf26, LAMA2, GJD2, ZNRF3, CD55, MIP, and ALPPL2) and confirmed one previously reported AL locus (ZC3H11B). Of the nine loci, five (LAMA2, GJD2, CD55, ALPPL2, and ZC3H11B) were associated with refraction in 18 independent cohorts (n = 23,591). Differential gene expression was observed for these loci in minus-lens-induced myopia mouse experiments and human ocular tissues. Two of the AL genes, RSPO1 and ZNRF3, are involved in Wnt signaling, a pathway playing a major role in the regulation of eyeball size. This study provides evidence of shared genes between AL and refraction, but importantly also suggests that these traits may have unique pathways. PMID:24144296

  3. Refractive error, visual acuity and causes of vision loss in children in Shandong, China. The Shandong Children Eye Study.

    Directory of Open Access Journals (Sweden)

    Jian Feng Wu

    Full Text Available PURPOSE: To examine the prevalence of refractive errors and prevalence and causes of vision loss among preschool and school children in East China. METHODS: Using a random cluster sampling in a cross-sectional school-based study design, children with an age of 4-18 years were selected from kindergartens, primary schools, and junior and senior high schools in the rural Guanxian County and the city of Weihai. All children underwent a complete ocular examination including measurement of uncorrected (UCVA and best corrected visual acuity (BCVA and auto-refractometry under cycloplegia. Myopia was defined as refractive error of ≤-0.5 diopters (D, high myopia as ≤ -6.0D, and amblyopia as BCVA ≤ 20/32 without any obvious reason for vision reduction and with strabismus or refractive errors as potential reasons. RESULTS: Out of 6364 eligible children, 6026 (94.7% children participated. Prevalence of myopia (overall: 36.9 ± 0.6%;95% confidence interval (CI:36.0,38.0 increased (P<0.001 from 1.7 ± 1.2% (95%CI:0.0,4.0 in the 4-years olds to 84.6 ± 3.2% (95%CI:78.0,91.0 in 17-years olds. Myopia was associated with older age (OR:1.56;95%CI:1.52,1.60;P<0.001, female gender (OR:1.22;95%CI:1.08,1.39;P = 0.002 and urban region (OR:2.88;95%CI:2.53,3.29;P<0.001. Prevalence of high myopia (2.0 ± 0.2% increased from 0.7 ± 0.3% (95%CI:0.1,1.3 in 10-years olds to 13.9 ± 3.0 (95%CI:7.8,19.9 in 17-years olds. It was associated with older age (OR:1.50;95%CI:1.41,1.60;P<0.001 and urban region (OR:3.11;95%CI:2.08,4.66;P<0.001. Astigmatism (≥ 0.75D (36.3 ± 0.6%;95%CI:35.0,38.0 was associated with older age (P<0.001;OR:1.06;95%CI:1.04,1.09, more myopic refractive error (P<0.001;OR:0.94;95%CI:0.91,0.97 and urban region (P<0.001;OR:1.47;95%CI:1.31,1.64. BCVA was ≤ 20/40 in the better eye in 19 (0.32% children. UCVA ≤ 20/40 in at least one eye was found in 2046 (34.05% children, with undercorrected refractive error as cause in 1975 (32.9% children. Amblyopia

  4. Past and present of corneal refractive surgery

    DEFF Research Database (Denmark)

    Vestergaard, Anders Højslet

    Surgical correction of refractive errors is becoming increasingly popular. In the 1990s, the excimer laser revolutionized the field of corneal refractive surgery with PRK and LASIK, and lately refractive lenticule extraction (ReLEx) of intracorneal tissue, using only a femtosecond laser, has become...

  5. Relationship between refractive error and ocular biometrics in twin children: the Guangzhou Twin Eye Study.

    Science.gov (United States)

    Wang, Decai; Liu, Bin; Huang, Shengsong; Huang, Wenyong; He, Mingguang

    2014-09-01

    A cross-sectional study was conducted to explore the relationship between refractive error and ocular biometrics in children from the Guangzhou twin eye study. Twin participants aged 7-15 years were selected from Guangzhou Twin Eye Study. Ocular examinations included visual acuity measurement, ocular motility evaluation, autorefraction under cycloplegia, and anterior segment, media, and fundus examination. Axial length (AL), anterior chamber depth (ACD), and corneal curvature radius were measured using partial coherence laser interferometry. A multivariate linear regression model was used for statistical analysis. Twin children from Guangzhou city showed a decreased spherical equivalent with age, whereas both AL and ACD were increased and corneal curvature radius remained unchanged. When adjusted by age and gender, the data from 77% of twins presenting with spherical equivalent changes indicated that these were caused by predictable variables (R2 = 0.77, P biometrics. Refractive status is largely determined by axial length as the major factor.

  6. Comparison of quality of life between myopic patients with spectacles and contact lenses, and patients who have undergone refractive surgery

    Directory of Open Access Journals (Sweden)

    Nastaran Shams

    2015-03-01

    Conclusion: Quality of life for people with myopia who had the refractive surgery was better than people with myopia who wore spectacles or contact lenses. Although quality of life in people with myopia who had the refractive surgery was less than emmetropia, it seems that refractive surgery improves quality of life of myopic patients.

  7. Visual Performance on the Small Letter Contrast Test: Effects of Aging, Low Luminance and Refractive Error

    Science.gov (United States)

    2000-08-01

    luminance performance and aviation, many aviators develop ametropias refractive error having comparable effects on during their careers. We were... statistically (0.04 logMAR, the non-aviator group. Separate investigators at p=0.01), but not clinically significant (ə/2 line different research facilities... statistically significant (0.11 ± 0.1 logCS, t=4.0, sensitivity on the SLCT decreased for the aviator pɘ.001), yet there is significant overlap group at a

  8. The relationship between the retinal image quality and the refractive index of defects arising in IOL: numerical analysis

    Science.gov (United States)

    Geniusz, Malwina

    2017-09-01

    The best treatment for cataract patients, which allows to restore clear vision is implanting an artificial intraocular lens (IOL). The image quality of the lens has a significant impact on the quality of patient's vision. After a long exposure the implant to aqueous environment some defects appear in the artificial lenses. The defects generated in the IOL have different refractive indices. For example, glistening phenomenon is based on light scattering on the oval microvacuoles filled with an aqueous humor which refractive index value is about 1.34. Calcium deposits are another example of lens defects and they can be characterized by the refractive index 1.63. In the presented studies it was calculated how the difference between the refractive indices of the defect and the refractive index of the lens material affects the quality of image. The OpticStudio Professional program (from Radiant Zemax, LLC) was used for the construction of the numerical model of the eye with IOL and to calculate the characteristics of the retinal image. Retinal image quality was described in such characteristics as Point Spread Function (PSF) and the Optical Transfer Function with amplitude and phase. The results show a strong correlation between the refractive indices difference and retinal image quality.

  9. Peripheral refractive correction and automated perimetric profiles.

    Science.gov (United States)

    Wild, J M; Wood, J M; Crews, S J

    1988-06-01

    The effect of peripheral refractive error correction on the automated perimetric sensitivity profile was investigated on a sample of 10 clinically normal, experienced observers. Peripheral refractive error was determined at eccentricities of 0 degree, 20 degrees and 40 degrees along the temporal meridian of the right eye using the Canon Autoref R-1, an infra-red automated refractor, under the parametric conditions of the Octopus automated perimeter. Perimetric sensitivity was then undertaken at these eccentricities (stimulus sizes 0 and III) with and without the appropriate peripheral refractive correction using the Octopus 201 automated perimeter. Within the measurement limits of the experimental procedures employed, perimetric sensitivity was not influenced by peripheral refractive correction.

  10. Analysis of the effects of Eye-Tracker performance on the pulse positioning errors during refractive surgery☆

    Science.gov (United States)

    Arba-Mosquera, Samuel; Aslanides, Ioannis M.

    2012-01-01

    Purpose To analyze the effects of Eye-Tracker performance on the pulse positioning errors during refractive surgery. Methods A comprehensive model, which directly considers eye movements, including saccades, vestibular, optokinetic, vergence, and miniature, as well as, eye-tracker acquisition rate, eye-tracker latency time, scanner positioning time, laser firing rate, and laser trigger delay have been developed. Results Eye-tracker acquisition rates below 100 Hz correspond to pulse positioning errors above 1.5 mm. Eye-tracker latency times to about 15 ms correspond to pulse positioning errors of up to 3.5 mm. Scanner positioning times to about 9 ms correspond to pulse positioning errors of up to 2 mm. Laser firing rates faster than eye-tracker acquisition rates basically duplicate pulse-positioning errors. Laser trigger delays to about 300 μs have minor to no impact on pulse-positioning errors. Conclusions The proposed model can be used for comparison of laser systems used for ablation processes. Due to the pseudo-random nature of eye movements, positioning errors of single pulses are much larger than observed decentrations in the clinical settings. There is no single parameter that ‘alone’ minimizes the positioning error. It is the optimal combination of the several parameters that minimizes the error. The results of this analysis are important to understand the limitations of correcting very irregular ablation patterns.

  11. Cost-effectiveness of screening and correcting refractive errors in school children in Africa, Asia, America and Europe.

    Science.gov (United States)

    Baltussen, Rob; Naus, Jeroen; Limburg, Hans

    2009-02-01

    To estimate the costs and effects of alternative strategies for annual screening of school children for refractive errors, and the provision of spectacles, in different WHO sub-regions in Africa, Asia, America and Europe. We developed a mathematical simulation model for uncorrected refractive error, using prevailing prevalence and incidence rates. Remission rates reflected the absence or presence of screening strategies for school children. All screening strategies were implemented for a period of 10 years and were compared to a situation were no screening was implemented. Outcome measures were life years adjusted for disability (DALYs), costs of screening and provision of spectacles and follow-up for six different screening strategies, and cost-effectiveness in international dollars per DALY averted. Epidemiological information was derived from the burden of disease study from the World Health Organization (WHO). Cost data were derived from large databases from the WHO. Both univariate and multivariate sensitivity analyses were performed on key parameters to determine the robustness of the model results. In all regions, screening of 5-15 years old children yields most health effects, followed by screening of 11-15 years old, 5-10 years old, and screening of 8 and 13 years old. Screening of broad-age intervals is always more costly than screening of single-age intervals, and there are important economies of scale for simultaneous screening of both 5-10 and 11-15-year-old children. In all regions, screening of 11-15 years old is the most cost-effective intervention, with the cost per DALY averted ranging from I$67 per DALY averted in the Asian sub-region to I$458 per DALY averted in the European sub-region. The incremental cost per DALY averted of screening 5-15 years old ranges between I$111 in the Asian sub-region to I$672 in the European sub-region. Considering the conservative study assumptions and the robustness of study conclusions towards changes in these

  12. Atmosphere Refraction Effects in Object Locating for Optical Satellite Remote Sensing Images

    Directory of Open Access Journals (Sweden)

    YAN Ming

    2015-09-01

    Full Text Available The collinear rigorous geometric model contains the atmosphere refraction geometric error in off-nadir observation. In order to estimate and correct the atmosphere refraction geometric error, the ISO international standard atmospheric model and Owens atmosphere refractive index algorithm are applied to calculate the index of atmosphere refraction in different latitude and altitude. The paper uses the weighted mean algorithm to reduce the eight layers ISO standard atmospheric model into a simple troposphere and stratosphere two layers spherical atmosphere. And the LOS vector track geometric algorithm is used to estimate the atmosphere refraction geometric error in different observation off-nadir angle. The results show that the atmosphere refraction will introduce about 2.5 m or 9 m geometric displacement in 30 or 45 degree off-nadir angle individual. Therefore, during geo-location processing of agile platform and extra wide high spatial resolution imagery, there is need to take into account the influence of atmosphere refraction and correct the atmosphere refraction geometric error to enhance the geo-location precision without GCPs.

  13. The prevalence of uncorrected refractive error in urban, suburban, exurban and rural primary school children in Indonesian population

    Directory of Open Access Journals (Sweden)

    Indra Tri Mahayana

    2017-11-01

    Full Text Available Uncorrected refractive error (URE is a major health problem among school children. This study was aimed to determine the frequency and patterns of URE across 4 gradients of residential densities (urban, exurban, suburban and rural. This was a cross-sectional study of school children from 3 districts in Yogyakarta and 1 district near Yogyakarta, Indonesia. The information regarding age, sex, school and school grader were recorded. The Snellen’s chart was used to measure the visual acuity and to perform the subjective refraction. The district was then divided into urban, suburban, exurban and rural area based on their location and population. In total, 410 school children were included in the analyses (urban=79, exurban=73, suburban=160 and rural=98 school children. Urban school children revealed the worst visual acuity (P<0.001 and it was significant when compared with exurban and rural. The proportion of URE among urban, suburban, exurban and rural area were 10.1%, 12.3%, 3.8%, and 1%, respectively, and it was significant when compared to the proportion of ametropia and corrected refractive error across residential densities (P=0.003. The risk of URE development in urban, suburban, exurban, and rural were 2.218 (95%CI: 0.914-5.385, 3.019 (95%CI: 1.266-7.197, 0.502 (95%CI: 0.195-1.293, and 0.130 (95%CI:0.017-0.972, respectively. Urban school children showed the worst visual acuity. The school children in urban and suburban residential area had 2 and 3 times higher risk of developing the URE.

  14. Visual impairment attributable to uncorrected refractive error and other causes in the Ghanaian youth: The University of Cape Coast Survey.

    Science.gov (United States)

    Abokyi, Samuel; Ilechie, Alex; Nsiah, Peter; Darko-Takyi, Charles; Abu, Emmanuel Kwasi; Osei-Akoto, Yaw Jnr; Youfegan-Baanam, Mathurin

    2016-01-01

    To determine the prevalence of visual impairment attributable to refractive error and other causes in a youthful Ghanaian population. A prospective survey of all consecutive visits by first-year tertiary students to the Optometry clinic between August, 2013 and April, 2014. Of the 4378 first-year students aged 16-39 years enumerated, 3437 (78.5%) underwent the eye examination. The examination protocol included presenting visual acuity (PVA), ocular motility, and slit-lamp examination of the external eye, anterior segment and media, and non-dilated fundus examination. Pinhole acuity and fundus examination were performed when the PVA≤6/12 in one or both eyes to determine the principal cause of the vision loss. The mean age of participants was 21.86 years (95% CI: 21.72-21.99). The prevalence of bilateral visual impairment (BVI; PVA in the better eye ≤6/12) and unilateral visual impairment UVI; PVA in the worse eye ≤6/12) were 3.08% (95% CI: 2.56-3.72) and 0.79% (95% CI: 0.54-1.14), respectively. Among 106 participants with BVI, refractive error (96.2%) and corneal opacity (3.8%) were the causes. Of the 27 participants with UVI, refractive error (44.4%), maculopathy (18.5%) and retinal disease (14.8%) were the major causes. There was unequal distribution of BVI in the different age groups, with those above 20 years having a lesser burden. Eye screening and provision of affordable spectacle correction to the youth could be timely to eliminate visual impairment. Copyright © 2014 Spanish General Council of Optometry. Published by Elsevier Espana. All rights reserved.

  15. Compensation of X-ray mirror shape-errors using refractive optics

    Energy Technology Data Exchange (ETDEWEB)

    Sawhney, Kawal, E-mail: Kawal.sawhney@diamond.ac.uk; Laundy, David; Pape, Ian [Diamond Light Source, Harwell Science and Innovation Campus, Didcot, Oxfordshire OX11 0DE (United Kingdom); Dhamgaye, Vishal [Indus Synchrotrons Utilisation Division, Raja Ramanna Centre for Advanced Technology, Indore 452012 (India)

    2016-08-01

    Focusing of X-rays to nanometre scale focal spots requires high precision X-ray optics. For nano-focusing mirrors, height errors in the mirror surface retard or advance the X-ray wavefront and after propagation to the focal plane, this distortion of the wavefront causes blurring of the focus resulting in a limit on the spatial resolution. We describe here the implementation of a method for correcting the wavefront that is applied before a focusing mirror using custom-designed refracting structures which locally cancel out the wavefront distortion from the mirror. We demonstrate in measurements on a synchrotron radiation beamline a reduction in the size of the focal spot of a characterized test mirror by a factor of greater than 10 times. This technique could be used to correct existing synchrotron beamline focusing and nanofocusing optics providing a highly stable wavefront with low distortion for obtaining smaller focus sizes. This method could also correct multilayer or focusing crystal optics allowing larger numerical apertures to be used in order to reduce the diffraction limited focal spot size.

  16. Refraction-compensated motion tracking of unrestrained small animals in positron emission tomography.

    Science.gov (United States)

    Kyme, Andre; Meikle, Steven; Baldock, Clive; Fulton, Roger

    2012-08-01

    Motion-compensated radiotracer imaging of fully conscious rodents represents an important paradigm shift for preclinical investigations. In such studies, if motion tracking is performed through a transparent enclosure containing the awake animal, light refraction at the interface will introduce errors in stereo pose estimation. We have performed a thorough investigation of how this impacts the accuracy of pose estimates and the resulting motion correction, and developed an efficient method to predict and correct for refraction-based error. The refraction model underlying this study was validated using a state-of-the-art motion tracking system. Refraction-based error was shown to be dependent on tracking marker size, working distance, and interface thickness and tilt. Correcting for refraction error improved the spatial resolution and quantitative accuracy of motion-corrected positron emission tomography images. Since the methods are general, they may also be useful in other contexts where data are corrupted by refraction effects. Crown Copyright © 2012. Published by Elsevier B.V. All rights reserved.

  17. The U.S. Air Force Photorefractive Keratectomy (PRK) Study: Evaluation of Residual Refractive Error and High- and Low-Contrast Visual Acuity

    Science.gov (United States)

    2006-07-01

    amounts of ametropia . The fact that performance remained relatively constant after PRK meant that there were no significant negative effects, with...refractive errors, which would have been substantial even for small amounts of ametropia . 5.6 Rabin Small Letter Contrast Test The Rabin SLCT data are

  18. Trachoma, cataracts and uncorrected refractive error are still important contributors to visual morbidity in two remote indigenous communities of the Northern Territory, Australia.

    Science.gov (United States)

    Wright, Heathcote R; Keeffe, Jill E; Taylor, Hugh R

    2009-08-01

    To assess the contribution of trachoma, cataract and refractive error to visual morbidity among Indigenous adults living in two remote communities of the Northern Territory. Cross-sectional survey of all adults aged 40 and over within a desert and coastal community. Visual acuity, clinical signs of trachoma using the simplified WHO grading system and assessment of cataract through a non-dilated pupil. Two hundred and sixty individuals over the age of 40 years participated in the study. The prevalence of visual impairment (coastal community (P coastal community. Trachoma, cataract and uncorrected refractive error remain significant contributors to visual morbidity in at least two remote indigenous communities. A wider survey is required to determine if these findings represent a more widespread pattern and existing eye care services may need to be re-assessed to determine the cause of this unmet need.

  19. [Refractive precision and objective quality of vision after toric lens implantation in cataract surgery].

    Science.gov (United States)

    Debois, A; Nochez, Y; Bezo, C; Bellicaud, D; Pisella, P-J

    2012-10-01

    To study efficacy and predictability of toric IOL implantation for correction of preoperative corneal astigmatism by analysing spherocylindrical refractive precision and objective quality of vision. Prospective study of 13 eyes undergoing micro-incisional cataract surgery through a 1.8mm corneal incision with toric IOL implantation (Lentis L313T(®), Oculentis) to treat over one D of preoperative corneal astigmatism. Preoperative evaluation included keratometry, subjective refraction, and total and corneal aberrometry (KR-1(®), Topcon). Six months postoperatively, measurements included slit lamp photography, documenting IOL rotation, tilt or decentration, uncorrected visual acuity, best-corrected visual acuity and objective quality of vision measurement (OQAS(®) Visiometrics, Spain). Postoperatively, mean uncorrected distance visual acuity was 8.33/10 ± 1.91 (0.09 ± 0.11 LogMar). Mean postoperative refractive sphere was 0.13 ± 0.73 diopters. Mean refractive astigmatism was -0.66 ± 0.56 diopters with corneal astigmatism of 2.17 ± 0.68 diopters. Mean IOL rotation was 4.4° ± 3.6° (range 0° to 10°). Mean rotation of this IOL at 6 months was less than 5°, demonstrating stability of the optic within the capsular bag. Objective quality of vision measurements were consistent with subjective uncorrected visual acuity. Implantation of the L313T(®) IOL is safe and effective for correction of corneal astigmatism in 1.8mm micro-incisional cataract surgery. Copyright © 2012 Elsevier Masson SAS. All rights reserved.

  20. Public sector refraction and spectacle dispensing in low-resource countries of the Western Pacific.

    Science.gov (United States)

    Ramke, Jacqueline; du Toit, Rènée; Palagyi, Anna; Williams, Carmel; Brian, Garry

    2008-05-01

    Given that uncorrected refractive error is a frequent cause of vision impairment, and that there is a high unmet need for spectacles, an appraisal of public sector arrangements for the correction of refractive error was conducted in eight Pacific Island countries. Mixed methods (questionnaire and semi-structured interviews) were used to collect information from eye care personnel (from Fiji, Papua New Guinea, Solomon Islands, Vanuatu, Cook Islands, Samoa, Tonga and Tuvalu) attending a regional eye health workshop in 2005. Fiji, Tonga and Vanuatu had Vision 2020 eye care plans that included refraction services, but not spectacle provision. There was wide variation in public sector spectacle dispensing services, but, except in Samoa, ready-made spectacles and a full cost recovery pricing strategy were the mainstay. There were no systems for the registration of personnel, nor guidelines for clinical or systems management. The refraction staff to population ratio varied considerably. Solomon Islands, Tuvalu and Vanuatu had the best coverage by services, either fixed or outreach. Most services had little promotional activity or community engagement. To be successful, it would seem that public sector refraction services should answer a real and perceived need, fit within prevailing policy and legislation, value, train, retain and equip employees, be well managed, be accessible and affordable, be responsive to consumers, and provide ongoing good quality outcomes. To this end, a checklist to aid the initiation and maintenance of refraction and spectacle systems in low-resource countries has been constructed.

  1. Refractive surgery or contact lenses – how and when to decide?

    Directory of Open Access Journals (Sweden)

    Xu K

    2011-11-01

    Full Text Available Kunyong Xu1, Vishal Jhanji2 1Michael G DeGroote School of Medicine, McMaster University, Hamilton, Ontario, Canada; 2Department of Ophthalmology and Visual Sciences, The Chinese University of Hong Kong, Hong Kong Abstract: Correction of refractive errors can be achieved with spectacles, contact lenses, and refractive surgery. The past decade has seen a surge in the availability of alternatives for patients and surgeons in terms of both surgical and nonsurgical options for the management of refractive errors. Newer generation contact lenses provide enhanced safety and better handling, whereas modern-day refractive surgery presents a plethora of choices based on the clinical characteristics and requirements of patients. We have moved from an era of "one size fits all" to a purely customized way of treating patients with refractive errors. This review presents the background, advantages, and disadvantages of the two most commonly used options for correction of ametropia, ie, contact lenses and refractive surgery. Keywords: laser-assisted in situ keratomileusis, contact lens, patient selection, complications, outcomes

  2. Trends in refractive surgery at an academic center: 2007-2009

    Directory of Open Access Journals (Sweden)

    Kuo Irene C

    2011-05-01

    Full Text Available Abstract Background The United States officially entered a recession in December 2007, and it officially exited the recession in December 2009, according to the National Bureau of Economic Research. Since the economy may affect not only the volume of excimer laser refractive surgery, but also the clinical characteristics of patients undergoing surgery, our goal was to compare the characteristics of patients completing excimer laser refractive surgery and the types of procedures performed in the summer quarter in 2007 and the same quarter in 2009 at an academic center. A secondary goal was to determine whether the volume of astigmatism- or presbyopia-correcting intraocular lenses (IOLs has concurrently changed because like laser refractive surgery, these "premium" IOLs involve out-of-pocket costs for patients. Methods Retrospective case series. Medical records were reviewed for all patients completing surgery at the Wilmer Laser Vision Center in the summer quarter of 2007 and the summer quarter of 2009. Outcome measures were the proportions of treated refractive errors, the proportion of photorefractive keratectomy (PRK vs. laser-assisted in-situ keratomileusis (LASIK, and the mean age of patients in each quarter. Chi-square test was used to compare the proportions of treated refractive errors and the proportions of procedures; two-tailed t-test to compare the mean age of patients; and two-tailed z-test to compare proportions of grouped refractive errors in 2007 vs. 2009; alpha = 0.05 for all tests. Refractive errors were grouped by the spherical equivalent of the manifest refraction and were considered "low myopia" for 6 diopters (D of myopia or less, "high myopia" for more than 6 D, and "hyperopia" for any hyperopia. Billing data were reviewed to obtain the volume of premium IOLs. Results Volume of laser refractive procedures decreased by at least 30%. The distribution of proportions of treated refractive errors did not change (p = 0.10. The

  3. Trends in refractive surgery at an academic center: 2007-2009.

    Science.gov (United States)

    Kuo, Irene C

    2011-05-14

    The United States officially entered a recession in December 2007, and it officially exited the recession in December 2009, according to the National Bureau of Economic Research. Since the economy may affect not only the volume of excimer laser refractive surgery, but also the clinical characteristics of patients undergoing surgery, our goal was to compare the characteristics of patients completing excimer laser refractive surgery and the types of procedures performed in the summer quarter in 2007 and the same quarter in 2009 at an academic center. A secondary goal was to determine whether the volume of astigmatism- or presbyopia-correcting intraocular lenses (IOLs) has concurrently changed because like laser refractive surgery, these "premium" IOLs involve out-of-pocket costs for patients. Retrospective case series. Medical records were reviewed for all patients completing surgery at the Wilmer Laser Vision Center in the summer quarter of 2007 and the summer quarter of 2009. Outcome measures were the proportions of treated refractive errors, the proportion of photorefractive keratectomy (PRK) vs. laser-assisted in-situ keratomileusis (LASIK), and the mean age of patients in each quarter. Chi-square test was used to compare the proportions of treated refractive errors and the proportions of procedures; two-tailed t-test to compare the mean age of patients; and two-tailed z-test to compare proportions of grouped refractive errors in 2007 vs. 2009; alpha = 0.05 for all tests. Refractive errors were grouped by the spherical equivalent of the manifest refraction and were considered "low myopia" for 6 diopters (D) of myopia or less, "high myopia" for more than 6 D, and "hyperopia" for any hyperopia. Billing data were reviewed to obtain the volume of premium IOLs. Volume of laser refractive procedures decreased by at least 30%. The distribution of proportions of treated refractive errors did not change (p = 0.10). The proportion of high myopes, however, decreased (p = 0

  4. Theoretical analyses of the refractive implications of transepithelial PRK ablations.

    Science.gov (United States)

    Arba Mosquera, Samuel; Awwad, Shady T

    2013-07-01

    To analyse the refractive implications of single-step, transepithelial photorefractive keratectomy (TransPRK) ablations. A simulation for quantifying the refractive implications of TransPRK ablations has been developed. The simulation includes a simple modelling of corneal epithelial profiles, epithelial ablation profiles as well as refractive ablation profiles, and allows the analytical quantification of the refractive implications of TransPRK in terms of wasted tissue, achieved optical zone (OZ) and induced refractive error. Wasted tissue occurs whenever the actual corneal epithelial profile is thinner than the applied epithelial ablation profile, achieved OZ is reduced whenever the actual corneal epithelial profile is thicker than the applied epithelial ablation profile and additional refractive errors are induced whenever the actual difference centre-to-periphery in the corneal epithelial profile deviates from the difference in the applied epithelial ablation profile. The refractive implications of TransPRK ablations can be quantified using simple theoretical simulations. These implications can be wasted tissue (∼14 µm, if the corneal epithelial profile is thinner than the ablated one), reduced OZ (if the corneal epithelial profile is thicker than ablated one, very severe for low corrections) and additional refractive errors (∼0.66 D, if the centre-to-periphery progression of the corneal epithelial profile deviates from the progression of the ablated one). When TransPRK profiles are applied to normal, not previously treated, non-pathologic corneas, no specific refractive implications associated to the transepithelial profile can be anticipated; TransPRK would provide refractive outcomes equal to those of standard PRK. Adjustments for the planned OZ and, in the event of retreatments, for the target sphere can be easily derived.

  5. Comparison of objective refraction in darkness to cycloplegic refraction: a pilot study.

    Science.gov (United States)

    Vasudevan, Balamurali; Ciuffreda, Kenneth J; Meehan, Kelly; Grk, Dejana; Cox, Misty

    2016-03-01

    The aim was to assess non-cycloplegic objective refraction in darkness using an open-field auto-refractor, and furthermore to compare it with distance cycloplegic subjective refraction and distance cycloplegic retinoscopy in the light, in children and young adults. Twenty-three, visually-normal, young-adults (46 eyes) ages 23 to 31 years, and five children (10 eyes) ages five to 12 years, participated in the study. The spherical component of their refraction ranged from -2.25 D to +3.75 D with a mean of +1.80 D, and a mean cylinder of -0.70 D. Three techniques were used to assess refractive error. An objective measure of the non-cycloplegic refractive state was obtained using an open-field autorefractor (WAM-5500) after five minutes in the dark to allow for dissipation of accommodative transients and relaxation of accommodation. In addition, both distance retinoscopy and subjective distance refraction were performed following cycloplegia (Cyclopentolate, 1%) using conventional clinical procedures. All measurements were obtained on the same day within a single session. The spherical component of the refraction was compared among the three techniques in both the children and adults. There was no significant difference in spherical refraction among the three techniques: non-cycloplegic objective refraction in the dark, distance cycloplegic retinoscopy and distance cycloplegic subjective refraction, in either the adults [F(2, 137) = 0.79, p = 0.45] or the children [F(2, 27) = 0.47, p = 0.62]. Mean difference in the spherical component between refraction in the dark and the cycloplegic distance retinoscopy was -0.34 D (r = 0.89) in the adults and +0.14 D (r = 0.96) in the children. The mean difference in spherical component between refraction in the dark and the cycloplegic distance subjective refraction was -0.25 D (r = 0.92) in the adults and -0.05 D (r = 0.95) in the children. Comparison of the spherical refractive component between the three techniques was not

  6. Axial Length/Corneal Radius of Curvature Ratio and Refractive ...

    African Journals Online (AJOL)

    2017-06-14

    Jun 14, 2017 ... of individuals,[2,5-8] the relationship between CR and refractive status ... the relationship between refractive error and ocular .... AG, 07740 Jena Germany). ..... adult population in rural Myanmar: The Meiktila eye study. Clin.

  7. Prevalence and risk factors for refractive errors in the South Indian adult population: The Andhra Pradesh Eye disease study

    Directory of Open Access Journals (Sweden)

    Sannapaneni Krishnaiah

    2008-12-01

    Full Text Available Sannapaneni Krishnaiah1,2,3, Marmamula Srinivas1,2,3, Rohit C Khanna1,2, Gullapalli N Rao1,2,31L V Prasad Eye Institute, Banjara Hills, Hyderabad, India; 2International Center for Advancement of Rural Eye Care, L V Prasad Eye Institute, Banjara Hills, Hyderabad, India; 3Vision CRC, University of New South Wales, Sydney, NSW, AustraliaAim: To report the prevalence, risk factors and associated population attributable risk percentage (PAR for refractive errors in the South Indian adult population.Methods: A population-based cross-sectional epidemiologic study was conducted in the Indian state of Andhra Pradesh. A multistage cluster, systematic, stratified random sampling method was used to obtain participants (n = 10293 for this study.Results: The age-gender-area-adjusted prevalence rates in those ≥40 years of age were determined for myopia (spherical equivalent [SE] < −0.5 D 34.6% (95% confidence interval [CI]: 33.1–36.1, high-myopia (SE < −5.0 D 4.5% (95% CI: 3.8–5.2, hyperopia (SE > +0.5 D 18.4% (95% CI: 17.1–19.7, astigmatism (cylinder < −0.5 D 37.6% (95% CI: 36–39.2, and anisometropia (SE difference between right and left eyes >0.5 D 13.0% (95% CI: 11.9–14.1. The prevalence of myopia, astigmatism, high-myopia, and anisometropia significantly increased with increasing age (all p < 0.0001. There was no gender difference in prevalence rates in any type of refractive error, though women had a significantly higher rate of hyperopia than men (p < 0.0001. Hyperopia was significantly higher among those with a higher educational level (odds ratio [OR] 2.49; 95% CI: 1.51–3.95 and significantly higher among the hypertensive group (OR 1.24; 95% CI: 1.03–1.49. The severity of lens nuclear opacity was positively associated with myopia and negatively associated with hyperopia.Conclusions: The prevalence of myopia in this adult Indian population is much higher than in similarly aged white populations. These results confirm the previously

  8. An optomechanical model eye for ophthalmological refractive studies.

    Science.gov (United States)

    Arianpour, Ashkan; Tremblay, Eric J; Stamenov, Igor; Ford, Joseph E; Schanzlin, David J; Lo, Yuhwa

    2013-02-01

    To create an accurate, low-cost optomechanical model eye for investigation of refractive errors in clinical and basic research studies. An optomechanical fluid-filled eye model with dimensions consistent with the human eye was designed and fabricated. Optical simulations were performed on the optomechanical eye model, and the quantified resolution and refractive errors were compared with the widely used Navarro eye model using the ray-tracing software ZEMAX (Radiant Zemax, Redmond, WA). The resolution of the physical optomechanical eye model was then quantified with a complementary metal-oxide semiconductor imager using the image resolution software SFR Plus (Imatest, Boulder, CO). Refractive, manufacturing, and assembling errors were also assessed. A refractive intraocular lens (IOL) and a diffractive IOL were added to the optomechanical eye model for tests and analyses of a 1951 U.S. Air Force target chart. Resolution and aberrations of the optomechanical eye model and the Navarro eye model were qualitatively similar in ZEMAX simulations. Experimental testing found that the optomechanical eye model reproduced properties pertinent to human eyes, including resolution better than 20/20 visual acuity and a decrease in resolution as the field of view increased in size. The IOLs were also integrated into the optomechanical eye model to image objects at distances of 15, 10, and 3 feet, and they indicated a resolution of 22.8 cycles per degree at 15 feet. A life-sized optomechanical eye model with the flexibility to be patient-specific was designed and constructed. The model had the resolution of a healthy human eye and recreated normal refractive errors. This model may be useful in the evaluation of IOLs for cataract surgery. Copyright 2013, SLACK Incorporated.

  9. The prevalence of refractive error in three communities of Cape Town, South Africa

    Directory of Open Access Journals (Sweden)

    M. Otutu

    2012-12-01

    Full Text Available The prevalence, distribution and demographic associations of refractive error in three communities in Cape Town, South Africa were assessed. In this cross-sectional study, a clustered random sampling procedure was used to recruit participants (n=176; age=40.6±14.7 years; males=76, females=96 from Khayelitsha, Milnerton, and Mitchell’s Plain. From March to May 2010, participants underwent autore-fraction and subjective refraction eye examinations.A structured interview was used to collect data on sociodemographics, age, gender, level of education, employment and race. Participants younger than 15 years, non-residents, or residents for less than six months, who declined signing the informed consent forms were excluded from the study. In this study myopia was defined as the spherical equivalent value in the better eye of −1.00D or worse and hyperopia as the spherical equivalent value in the better eye of ≥1.00D. Astigmatism was defined as −0.50 cylinder or worse in the better eye. The prevalence of myopia was 17.4% with a 90% confidence interval (CI of 12.65-22.15, hyperopia was 13.4% (90% CI 9.13-17.67, and astigmatism was 60% (90% CI 53.86-66.14. Myopia was found to be significantly associated with race and age; while hyperopia was significantly associated with age, employment and race. The results of this study may assist in planning for eye care on district level. (S Afr Optom 2012 71(1 32-38

  10. Refractive Lenticule Implantation for Correction of Ametropia: Case Reports and Literature Review.

    Science.gov (United States)

    Lazaridis, A; Messerschmidt-Roth, A; Sekundo, W; Schulze, S

    2017-01-01

    The ReLEx® technique allows correction of refractive errors through the creation and extraction of refractive stromal lenticules. Contrary to excimer laser corneal refractive procedures, where the stromal tissue is photoablated, the extracted lenticules obtained with ReLEx® can be preserved. Recent studies and case reports have described autologous re-implantation and allogeneic implantation of refractive lenticules into femtosecond-laser created stromal pockets in order to reverse the refractive outcome of a myopic corneal refractive procedure, correct hyperopia, aphakia, presbyopia and treat keratoconus. The use of stromal lenticules has also been described for therapeutic purposes, with an allogenic lenticule being transplanted under a LASIK flap in order to restore corneal volume and reduce the refractive error in a case of excessive stromal tissue removal after LASIK. This review summarises the results of the latest case reports and studies that describe the implantation of cryopreserved or fresh refractive stromal lenticules and discusses the feasibility, safety and refractive outcomes of the procedure, on the basis of published literature as well as our own experience. Georg Thieme Verlag KG Stuttgart · New York.

  11. Refractive accuracy with light-adjustable intraocular lenses.

    Science.gov (United States)

    Villegas, Eloy A; Alcon, Encarna; Rubio, Elena; Marín, José M; Artal, Pablo

    2014-07-01

    To evaluate efficacy, predictability, and stability of refractive treatments using light-adjustable intraocular lenses (IOLs). University Hospital Virgen de la Arrixaca, Murcia, Spain. Prospective nonrandomized clinical trial. Eyes with a light-adjustable IOL (LAL) were treated with spatial intensity profiles to correct refractive errors. The effective changes in refraction in the light-adjustable IOL after every treatment were estimated by subtracting those in the whole eye and the cornea, which were measured with a Hartmann-Shack sensor and a corneal topographer, respectively. The refractive changes in the whole eye and light-adjustable IOL, manifest refraction, and visual acuity were obtained after every light treatment and at the 3-, 6-, and 12-month follow-ups. The study enrolled 53 eyes (49 patients). Each tested light spatial pattern (5 spherical; 3 astigmatic) produced a different refractive change (Plight adjustments induced a maximum change in spherical power of the light-adjustable IOL of between -1.98 diopters (D) and +2.30 D and in astigmatism of up to -2.68 D with axis errors below 9 degrees. Intersubject variability (standard deviation) ranged between 0.10 D and 0.40 D. The 2 required lock-in procedures induced a small myopic shift (range +0.01 to +0.57 D) that depended on previous adjustments. Light-adjustable IOL implantation achieved accurate refractive outcomes (around emmetropia) with good uncorrected distance visual acuity, which remained stable over time. Further refinements in nomograms and in the treatment's protocol would improve the predictability of refractive and visual outcomes with these IOLs. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2014 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  12. Age-Specific Prevalence of Visual Impairment and Refractive Error in Children Aged 3-10 Years in Shanghai, China.

    Science.gov (United States)

    Ma, Yingyan; Qu, Xiaomei; Zhu, Xiaofeng; Xu, Xun; Zhu, Jianfeng; Sankaridurg, Padmaja; Lin, Senlin; Lu, Lina; Zhao, Rong; Wang, Ling; Shi, Huijing; Tan, Hui; You, Xiaofang; Yuan, Hong; Sun, Sifei; Wang, Mingjin; He, Xiangui; Zou, Haidong; Congdon, Nathan

    2016-11-01

    We assessed changes in age-specific prevalence of refractive error at the time of starting school, by comparing preschool and school age cohorts in Shanghai, China. A cross-sectional study was done in Jiading District, Shanghai during November and December 2013. We randomly selected 7 kindergartens and 7 primary schools, with probability proportionate to size. Chinese children (n = 8398) aged 3 to 10 years were enumerated, and 8267 (98.4%) were included. Children underwent distance visual acuity assessment and refraction measurement by cycloplegic autorefraction and subjective refraction. The prevalence of uncorrected visual acuity (UCVA), presenting visual acuity, and best-corrected visual acuity in the better eye of ≤20/40 was 19.8%, 15.5%, and 1.7%, respectively. Among those with UCVA ≤ 20/40, 93.2% could achieve visual acuity of ≥20/32 with refraction. Only 28.7% (n = 465) of children with UCVA in the better eye of ≤20/40 wore glasses. Prevalence of myopia (spherical equivalent ≤-0.5 diopters [D] in at least one eye) increased from 1.78% in 3-year-olds to 52.2% in 10-year-olds, while prevalence of hyperopia (spherical equivalent ≥+2.0 D) decreased from 17.8% among 3-year-olds to 2.6% by 10 years of age. After adjusting for age, attending elite "high-level" school was statistically associated with greater myopia prevalence. The prevalence of myopia was lower or comparable to that reported in other populations from age 3 to 5 years, but increased dramatically after 6 years, consistent with a strong environmental role of schooling on myopia development.

  13. A web-based information system for management and analysis of patient data after refractive eye surgery.

    Science.gov (United States)

    Zuberbuhler, Bruno; Galloway, Peter; Reddy, Aravind; Saldana, Manuel; Gale, Richard

    2007-12-01

    The aim was to develop a software tool for refractive surgeons using a standard user-friendly web-based interface, providing the user with a secure environment to protect large volumes of patient data. The software application was named "Internet-based refractive analysis" (IBRA), and was programmed with the computer languages PHP, HTML and JavaScript, attached to the opensource MySQL database. IBRA facilitated internationally accepted presentation methods including the stability chart, the predictability chart and the safety chart; it was able to perform vector analysis for the course of a single patient or for group data. With the integrated nomogram calculation, treatment could be customised to reduce the postoperative refractive error. Multicenter functions permitted quality-control comparisons between different surgeons and laser units.

  14. The prevalence of refractive conditions in Puerto Rican adults attending an eye clinic system

    Directory of Open Access Journals (Sweden)

    Neisha M. Rodriguez

    2014-07-01

    Conclusion: Hyperopia is the most common refractive error and its prevalence and seems to increase among the aging population who visited the clinics. Further programs and studies must be developed to address the refractive errors needs of the adult Puerto Rican population.

  15. Topography-modified refraction (TMR): adjustment of treated cylinder amount and axis to the topography versus standard clinical refraction in myopic topography-guided LASIK.

    Science.gov (United States)

    Kanellopoulos, Anastasios John

    2016-01-01

    To evaluate the safety, efficacy, and contralateral eye comparison of topography-guided myopic LASIK with two different refraction treatment strategies. Private clinical ophthalmology practice. A total of 100 eyes (50 patients) in consecutive cases of myopic topography-guided LASIK procedures with the same refractive platform (FS200 femtosecond and EX500 excimer lasers) were randomized for treatment as follows: one eye with the standard clinical refraction (group A) and the contralateral eye with the topographic astigmatic power and axis (topography-modified treatment refraction; group B). All cases were evaluated pre- and post-operatively for the following parameters: refractive error, best corrected distance visual acuity (CDVA), uncorrected distance visual acuity (UDVA), topography (Placido-disk based) and tomography (Scheimpflug-image based), wavefront analysis, pupillometry, and contrast sensitivity. Follow-up visits were conducted for at least 12 months. Mean refractive error was -5.5 D of myopia and -1.75 D of astigmatism. In group A versus group B, respectively, the average UDVA improved from 20/200 to 20/20 versus 20/16; post-operative CDVA was 20/20 and 20/13.5; 1 line of vision gained was 27.8% and 55.6%; and 2 lines of vision gained was 5.6% and 11.1%. In group A, 27.8% of eyes had over -0.50 diopters of residual refractive astigmatism, in comparison to 11.7% in group B ( P Topography-modified refraction (TMR): topographic adjustment of the amount and axis of astigmatism treated, when different from the clinical refraction, may offer superior outcomes in topography-guided myopic LASIK. These findings may change the current clinical paradigm of the optimal subjective refraction utilized in laser vision correction.

  16. Refractive aim and visual outcome after phacoemulsification: A 2 ...

    African Journals Online (AJOL)

    2016-03-24

    Mar 24, 2016 ... was met, 21 eyes (14.3%) did not meet their refractive aim, 20 eyes (12.7%) were ... countries, where blindness is associated with considerable ... and better, the total range of refractive errors postoperatively ... required intraocular lenses (IOL), medical record efficiency, ..... problem that can be alleviated.

  17. Eye laterality: a comprehensive analysis in refractive surgery candidates.

    Science.gov (United States)

    Linke, Stephan J; Druchkiv, Vasyl; Steinberg, Johannes; Richard, Gisbert; Katz, Toam

    2013-08-01

    To explore eye laterality (higher refractive error in one eye) and its association with refractive state, spherical/astigmatic anisometropia, age and sex in refractive surgery candidates. Medical records of 12 493 consecutive refractive surgery candidates were filtered. Refractive error (subjective and cycloplegic) was measured in each subject and correlated with eye laterality. Only subjects with corrected distance visual acuity (CDVA) of >20/22 in each eye were enrolled to exclude amblyopia. Associations between eye laterality and refractive state were analysed by means of t-test, chi-squared test, Spearman's correlation and multivariate logistic regression analysis, respectively. There was no statistically significant difference in spherical equivalent between right (-3.47 ± 2.76 D) and left eyes (-3.47 ± 2.76 D, p = 0.510; Pearson's r = 0.948, p laterality for anisometropia >2.5 D in myopic (-5.64 ± 2.5 D versus -4.92 ± 2.6 D; p = 0.001) and in hyperopic (4.44 ± 1.69 D versus 3.04 ± 1.79 D; p = 0.025) subjects, (II) a tendency for left eye cylindrical laterality in myopic subjects, and (III) myopic male subjects had a higher prevalence of left eye laterality. (IV) Age did not show any significant impact on laterality. Over the full refractive spectrum, this study confirmed previously described strong interocular refractive correlation but revealed a statistically significant higher rate of right eye laterality for anisometropia >2.5 D. In general, our results support the use of data from one eye only in studies of ocular refraction. © 2013 The Authors. Acta Ophthalmologica © 2013 Acta Ophthalmologica Scandinavica Foundation.

  18. Refractive outcomes after multifocal intraocular lens exchange.

    Science.gov (United States)

    Kim, Eric J; Sajjad, Ahmar; Montes de Oca, Ildamaris; Koch, Douglas D; Wang, Li; Weikert, Mitchell P; Al-Mohtaseb, Zaina N

    2017-06-01

    To evaluate the refractive outcomes after multifocal intraocular lens (IOL) exchange. Cullen Eye Institute, Baylor College of Medicine, Houston, Texas, USA. Retrospective case series. Patients had multifocal IOL explantation followed by IOL implantation. Outcome measures included type of IOL, surgical indication, corrected distance visual acuity (CDVA), and refractive prediction error. The study comprised 29 patients (35 eyes). The types of IOLs implanted after multifocal IOL explantation included in-the-bag IOLs (74%), iris-sutured IOLs (6%), sulcus-fixated IOLs with optic capture (9%), sulcus-fixated IOLs without optic capture (9%), and anterior chamber IOLs (3%). The surgical indication for exchange included blurred vision (60%), photic phenomena (57%), photophobia (9%), loss of contrast sensitivity (3%), and multiple complaints (29%). The CDVA was 20/40 or better in 94% of eyes before the exchange and 100% of eyes after the exchange (P = .12). The mean refractive prediction error significantly decreased from 0.22 ± 0.81 diopter (D) before the exchange to -0.09 ± 0.53 D after the exchange (P exchange to 0.23 D after the exchange (P exchange can be performed safely with good visual outcomes using different types of IOLs. A lower refractive prediction error and a higher likelihood of 20/40 or better vision can be achieved with the implantation of the second IOL compared with the original multifocal IOL, regardless of the final IOL position. Copyright © 2017 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  19. Analytical models of optical refraction in the troposphere.

    Science.gov (United States)

    Nener, Brett D; Fowkes, Neville; Borredon, Laurent

    2003-05-01

    An extremely accurate but simple asymptotic description (with known error) is obtained for the path of a ray propagating over a curved Earth with radial variations in refractive index. The result is sufficiently simple that analytic solutions for the path can be obtained for linear and quadratic index profiles. As well as rendering the inverse problem trivial for these profiles, this formulation shows that images are uniformly magnified in the vertical direction when viewed through a quadratic refractive-index profile. Nonuniform vertical distortions occur for higher-order refractive-index profiles.

  20. Comparison of monochromatic aberrations in young adults with different visual acuity and refractive errors.

    Science.gov (United States)

    Yazar, Seyhan; Hewitt, Alex W; Forward, Hannah; McKnight, Charlotte M; Tan, Alex; Mountain, Jenny A; Mackey, David A

    2014-03-01

    To compare the monochromatic aberrations in a large cohort of 20-year-old Australians with differing levels of visual acuity and explore the relationship between these aberrations and refractive error. Lions Eye Institute, Perth, Western Australia, Australia. Cross-sectional analysis of a population-based cohort. Monochromatic aberrations were measured using a Zywave II wavefront aberrometer with natural pupils in a dark room. The logMAR corrected distance visual acuity (CDVA) was measured monocularly under normal illumination. Cycloplegic autorefraction was also performed. The study enrolled 2039 eyes of 1040 participants. Data from 1007 right eyes were analyzed. The median CDVA and spherical equivalent were -0.06 logMAR (interquartile range [IQR], -0.10 to 0.00) and +0.25 diopters (D) (IQR, -0.38 to 0.63), respectively. The median 6.0 mm higher-order aberration (HOA) was 0.58 μm (IQR, 0.44 to 0.79). Coma-like aberrations and 3rd-, 4th-, and 5th-order HOAs were significantly different between subjects with a CDVA of -0.10 logMAR or better and those with a CDVA worse than -0.10 logMAR. Fourth-order aberrations Z(4,-4) (P=.024) and Z(4,-2) (P=.029) and 2nd-order aberration Z(2,0) (Peyes, emmetropic eyes, and hyperopic eyes. Subjects with higher myopia had slightly higher total HOAs. The HOAs in this population were marginally higher than previously reported values. The findings confirm there is a difference in monochromatic aberrations between different vision and refractive groups. Results in this study will benefit decision-making processes in the clinical setting. Copyright © 2014 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  1. Photorefractive keratectomy in refractive accommodative esotropia.

    Science.gov (United States)

    Bilgihan, K; Akata, F; Or, M; Hasanreisoğlu, B

    1997-01-01

    Photorefractive keratectomy (PRK) was performed on a 19-year-old man with hyperopic astigmatism and refractive accommodative esotropia. The patient was orthophoric while wearing spectacles, but had an esotropia of 30 prism dioptres at near and distance vision without spectacles. The best corrected visual acuity of the right eye was 20/50 and of the left eye was 20/20. The excessive accommodative convergence of the patient was eliminated by correcting the hyperopic refractive error by performing PRK, and the patient became orthophoric after the treatment.

  2. Value of dual biometry in the detection and investigation of error in the preoperative prediction of refractive status following cataract surgery.

    LENUS (Irish Health Repository)

    Charalampidou, Sofia

    2012-02-01

    PURPOSE: To report the value of dual biometry in the detection of biometry errors. METHODS: Study 1: retrospective study of 224 consecutive cataract operations. The intraocular lens power calculation was based on immersion biometry. Study 2: immersion biometry was compared with optical coherence biometry (OCB) in terms of axial length, anterior chamber depth, keratometry readings and the recommended lens power to achieve emmetropia. Study 3: prospective study of 61 consecutive cataract operations. Both immersion and OCB were performed, but lens power calculation was based on the latter. RESULTS: Study 1: 115 (86%), 101 (75.4%), 90 (67.2%) and 50 (37.3%) of postoperative spherical equivalents were within +\\/-1.5 dioptres (D), +\\/-1.25 D, +\\/-1 D and +\\/-0.5 D of the target, respectively. Study 2: excellent agreement between axial length readings, anterior chamber depth readings and keratometry readings by immersion biometry and OCB was observed (reflected in a mean bias of -0.065 mm, -0.048 mm and +0.1803 D, respectively, in association with OCB). Agreement between the lens power recommended by each technique to achieve emmetropia was poor (mean bias of +1.16 D in association with OCB), but improved following appropriate modification of lens constants in the Accutome A-scan software (mean bias with OCB = -0.4 D). Study 3: 37 (92.5%) and 23 (57.5%) of operated eyes achieved a postoperative refraction within +\\/-1 D and +\\/-0.5 D of target, respectively. CONCLUSION: Systematic errors in biometry can exist, in the presence of acceptable postoperative refractive results. Dual biometry allows each biometric parameter to be scrutinized in isolation, and identify sources of error that may otherwise go undetected.

  3. Error induced by the estimation of the corneal power and the effective lens position with a rotationally asymmetric refractive multifocal intraocular lens.

    Science.gov (United States)

    Piñero, David P; Camps, Vicente J; Ramón, María L; Mateo, Verónica; Pérez-Cambrodí, Rafael J

    2015-01-01

    To evaluate the prediction error in intraocular lens (IOL) power calculation for a rotationally asymmetric refractive multifocal IOL and the impact on this error of the optimization of the keratometric estimation of the corneal power and the prediction of the effective lens position (ELP). Retrospective study including a total of 25 eyes of 13 patients (age, 50 to 83y) with previous cataract surgery with implantation of the Lentis Mplus LS-312 IOL (Oculentis GmbH, Germany). In all cases, an adjusted IOL power (PIOLadj) was calculated based on Gaussian optics using a variable keratometric index value (nkadj) for the estimation of the corneal power (Pkadj) and on a new value for ELP (ELPadj) obtained by multiple regression analysis. This PIOLadj was compared with the IOL power implanted (PIOLReal) and the value proposed by three conventional formulas (Haigis, Hoffer Q and Holladay I). PIOLReal was not significantly different than PIOLadj and Holladay IOL power (P>0.05). In the Bland and Altman analysis, PIOLadj showed lower mean difference (-0.07 D) and limits of agreement (of 1.47 and -1.61 D) when compared to PIOLReal than the IOL power value obtained with the Holladay formula. Furthermore, ELPadj was significantly lower than ELP calculated with other conventional formulas (P<0.01) and was found to be dependent on axial length, anterior chamber depth and Pkadj. Refractive outcomes after cataract surgery with implantation of the multifocal IOL Lentis Mplus LS-312 can be optimized by minimizing the keratometric error and by estimating ELP using a mathematical expression dependent on anatomical factors.

  4. THE INFLUENCE OF REFRACTIVE ERROR MANAGEMENT ON THE NATURAL HISTORY AND TREATMENT OUTCOME OF ACCOMMODATIVE ESOTROPIA (AN AMERICAN OPHTHALMOLOGICAL SOCIETY THESIS)

    Science.gov (United States)

    Black, Bradley Charles

    2006-01-01

    Purpose To evaluate the effect of refractive error management on resolution of accommodative esotropia, deterioration of accommodative esotropia, and the natural history of hypermetropia in accommodative esotropia. Methods Retrospective cohort study and nested case-control study of patients with accommodative esotropia untreated prior to diagnosis by the author. Eligibility criteria included esodeviation of ≥10 prism diopters (PD) on distance and near fixation on initial examination, hypermetropia, distance esodeviation <10 PD with full cycloplegic refraction correction on first follow-up examination, and at least 2 years of follow-up. Results The study included 285 patients with mean follow-up of 102 months. After age 7 years, mean annual decrease in hypermetropia was .24 D for patients wearing full cycloplegic refraction and for patients in whom hypermetropia was undercorrected by 1.00 D or more. Age at diagnosis (P < .0001), oblique muscle dysfunction (P < .0001), and abnormal distance-near relationship (P = .007) were associated with deterioration of accommodative esotropia. Of 51 patients with an intermittent abnormal distance-near relationship, 19 (37%) had increased hypermetropia on cycloplegic refraction, and prescription of the increased correction normalized the distance-near relationship. Conclusions The possibility that undercorrecting hypermetropia speeds its resolution is not supported by this study. Accommodative esotropia is usually stable, but younger age at diagnosis, oblique muscle dysfunction, and abnormal distance-near relationship are associated with deterioration. Undercorrection of hypermetropia can cause an abnormal distance-near relationship, which in turn can cause deterioration of accommodative esotropia. Aggressive undercorrection of hypermetropia should be pursued carefully, because the risk may outweigh the potential advantages. PMID:17471349

  5. Retinal image quality during accommodation.

    Science.gov (United States)

    López-Gil, Norberto; Martin, Jesson; Liu, Tao; Bradley, Arthur; Díaz-Muñoz, David; Thibos, Larry N

    2013-07-01

    We asked if retinal image quality is maximum during accommodation, or sub-optimal due to accommodative error, when subjects perform an acuity task. Subjects viewed a monochromatic (552 nm), high-contrast letter target placed at various viewing distances. Wavefront aberrations of the accommodating eye were measured near the endpoint of an acuity staircase paradigm. Refractive state, defined as the optimum target vergence for maximising retinal image quality, was computed by through-focus wavefront analysis to find the power of the virtual correcting lens that maximizes visual Strehl ratio. Despite changes in ocular aberrations and pupil size during binocular viewing, retinal image quality and visual acuity typically remain high for all target vergences. When accommodative errors lead to sub-optimal retinal image quality, acuity and measured image quality both decline. However, the effect of accommodation errors of on visual acuity are mitigated by pupillary constriction associated with accommodation and binocular convergence and also to binocular summation of dissimilar retinal image blur. Under monocular viewing conditions some subjects displayed significant accommodative lag that reduced visual performance, an effect that was exacerbated by pharmacological dilation of the pupil. Spurious measurement of accommodative error can be avoided when the image quality metric used to determine refractive state is compatible with the focusing criteria used by the visual system to control accommodation. Real focusing errors of the accommodating eye do not necessarily produce a reliably measurable loss of image quality or clinically significant loss of visual performance, probably because of increased depth-of-focus due to pupil constriction. When retinal image quality is close to maximum achievable (given the eye's higher-order aberrations), acuity is also near maximum. A combination of accommodative lag, reduced image quality, and reduced visual function may be a useful

  6. Effects of light refraction on the accuracy of camera calibration and reconstruction in underwater motion analysis.

    Science.gov (United States)

    Kwon, Young-Hoo; Casebolt, Jeffrey B

    2006-07-01

    One of the most serious obstacles to accurate quantification of the underwater motion of a swimmer's body is image deformation caused by refraction. Refraction occurs at the water-air interface plane (glass) owing to the density difference. Camera calibration-reconstruction algorithms commonly used in aquatic research do not have the capability to correct this refraction-induced nonlinear image deformation and produce large reconstruction errors. The aim of this paper is to provide a thorough review of: the nature of the refraction-induced image deformation and its behaviour in underwater object-space plane reconstruction; the intrinsic shortcomings of the Direct Linear Transformation (DLT) method in underwater motion analysis; experimental conditions that interact with refraction; and alternative algorithms and strategies that can be used to improve the calibration-reconstruction accuracy. Although it is impossible to remove the refraction error completely in conventional camera calibration-reconstruction methods, it is possible to improve the accuracy to some extent by manipulating experimental conditions or calibration frame characteristics. Alternative algorithms, such as the localized DLT and the double-plane method are also available for error reduction. The ultimate solution for the refraction problem is to develop underwater camera calibration and reconstruction algorithms that have the capability to correct refraction.

  7. Internal quality control of RIA with Tonks error calculation method

    International Nuclear Information System (INIS)

    Chen Xiaodong

    1996-01-01

    According to the methodology feature of RIA, an internal quality control chart with Tonks error calculation method which is suitable for RIA is designed. The quality control chart defines the value of the allowance error with normal reference range. The method has the simplicity of its performance and directly perceived through the senses. Taking the example of determining T 3 and T 4 , the calculation of allowance error, drawing of quality control chart and the analysis of result are introduced

  8. Tropospheric profiles of wet refractivity and humidity from the combination of remote sensing data sets and measurements on the ground

    Directory of Open Access Journals (Sweden)

    F. Hurter

    2013-11-01

    Full Text Available We reconstruct atmospheric wet refractivity profiles for the western part of Switzerland with a least-squares collocation approach from data sets of (a zenith path delays that are a byproduct of the GPS (global positioning system processing, (b ground meteorological measurements, (c wet refractivity profiles from radio occultations whose tangent points lie within the study area, and (d radiosonde measurements. Wet refractivity is a parameter partly describing the propagation of electromagnetic waves and depends on the atmospheric parameters temperature and water vapour pressure. In addition, we have measurements of a lower V-band microwave radiometer at Payerne. It delivers temperature profiles at high temporal resolution, especially in the range from ground to 3000 m a.g.l., though vertical information content decreases with height. The temperature profiles together with the collocated wet refractivity profiles provide near-continuous dew point temperature or relative humidity profiles at Payerne for the study period from 2009 to 2011. In the validation of the humidity profiles, we adopt a two-step procedure. We first investigate the reconstruction quality of the wet refractivity profiles at the location of Payerne by comparing them to wet refractivity profiles computed from radiosonde profiles available for that location. We also assess the individual contributions of the data sets to the reconstruction quality and demonstrate a clear benefit from the data combination. Secondly, the accuracy of the conversion from wet refractivity to dew point temperature and relative humidity profiles with the radiometer temperature profiles is examined, comparing them also to radiosonde profiles. For the least-squares collocation solution combining GPS and ground meteorological measurements, we achieve the following error figures with respect to the radiosonde reference: maximum median offset of relative refractivity error is −16% and quartiles are 5% to

  9. Experimental and predicted refractive index properties in ternary mixtures of associated liquids

    International Nuclear Information System (INIS)

    Sechenyh, Vitaliy V.; Legros, Jean-Claude; Shevtsova, Valentina

    2011-01-01

    Highlights: → Measurements of refractive indices of 200 different aqueous ternary mixtures have been performed for two wave lengths. → Refractive indices of the associated ternary mixtures can be modeled with a relative error of about 0.9. → Difference between experimental and calculated derivatives of refractive index with concentration is unsatisfactory large. - Abstract: Refractive indices of ternary mixtures formed by (water + ethanol + k-ethylene glycol) (when k is mono, di or tri) and (water + t-butanol + dimethyl sulfoxide) are presented over a wide range of mixture compositions. All measurements have been conducted at 298.15 K and atmospheric pressure using two light sources: one in the visible (λ = 670 nm) and the other in the infrared (λ = 925 nm) spectrum. The performance of several mixing rules that are commonly used in modeling optical constants are examined. We demonstrate that the refractive indices of the associated ternary mixtures can be modeled with a relative error of about 0.9% by using the thermodynamical properties of the pure components. The concentration derivatives of the refractive index are an important parameter, as they are required for different experimental techniques. These derivatives have been determined from the experimental data on refractive indices. However, applying mixing rules for calculation of the derivatives of the refractive indices with respect to concentrations does not provide satisfactory results in the case of ternary mixtures of associated liquids.

  10. Inverse radiation problem of temperature distribution in one-dimensional isotropically scattering participating slab with variable refractive index

    International Nuclear Information System (INIS)

    Namjoo, A.; Sarvari, S.M. Hosseini; Behzadmehr, A.; Mansouri, S.H.

    2009-01-01

    In this paper, an inverse analysis is performed for estimation of source term distribution from the measured exit radiation intensities at the boundary surfaces in a one-dimensional absorbing, emitting and isotropically scattering medium between two parallel plates with variable refractive index. The variation of refractive index is assumed to be linear. The radiative transfer equation is solved by the constant quadrature discrete ordinate method. The inverse problem is formulated as an optimization problem for minimizing an objective function which is expressed as the sum of square deviations between measured and estimated exit radiation intensities at boundary surfaces. The conjugate gradient method is used to solve the inverse problem through an iterative procedure. The effects of various variables on source estimation are investigated such as type of source function, errors in the measured data and system parameters, gradient of refractive index across the medium, optical thickness, single scattering albedo and boundary emissivities. The results show that in the case of noisy input data, variation of system parameters may affect the inverse solution, especially at high error values in the measured data. The error in measured data plays more important role than the error in radiative system parameters except the refractive index distribution; however the accuracy of source estimation is very sensitive toward error in refractive index distribution. Therefore, refractive index distribution and measured exit intensities should be measured accurately with a limited error bound, in order to have an accurate estimation of source term in a graded index medium.

  11. Error induced by the estimation of the corneal power and the effective lens position with a rotationally asymmetric refractive multifocal intraocular lens

    Directory of Open Access Journals (Sweden)

    David P. Piñero

    2015-06-01

    Full Text Available AIM:To evaluate the prediction error in intraocular lens (IOL power calculation for a rotationally asymmetric refractive multifocal IOL and the impact on this error of the optimization of the keratometric estimation of the corneal power and the prediction of the effective lens position (ELP.METHODS:Retrospective study including a total of 25 eyes of 13 patients (age, 50 to 83y with previous cataract surgery with implantation of the Lentis Mplus LS-312 IOL (Oculentis GmbH, Germany. In all cases, an adjusted IOL power (PIOLadj was calculated based on Gaussian optics using a variable keratometric index value (nkadj for the estimation of the corneal power (Pkadj and on a new value for ELP (ELPadj obtained by multiple regression analysis. This PIOLadj was compared with the IOL power implanted (PIOLReal and the value proposed by three conventional formulas (Haigis, Hoffer Q and Holladay Ⅰ.RESULTS:PIOLReal was not significantly different than PIOLadj and Holladay IOL power (P>0.05. In the Bland and Altman analysis, PIOLadj showed lower mean difference (-0.07 D and limits of agreement (of 1.47 and -1.61 D when compared to PIOLReal than the IOL power value obtained with the Holladay formula. Furthermore, ELPadj was significantly lower than ELP calculated with other conventional formulas (P<0.01 and was found to be dependent on axial length, anterior chamber depth and Pkadj.CONCLUSION:Refractive outcomes after cataract surgery with implantation of the multifocal IOL Lentis Mplus LS-312 can be optimized by minimizing the keratometric error and by estimating ELP using a mathematical expression dependent on anatomical factors.

  12. Effects of Atmospheric Refraction on an Airborne Weather Radar Detection and Correction Method

    Directory of Open Access Journals (Sweden)

    Lei Wang

    2015-01-01

    Full Text Available This study investigates the effect of atmospheric refraction, affected by temperature, atmospheric pressure, and humidity, on airborne weather radar beam paths. Using three types of typical atmospheric background sounding data, we established a simulation model for an actual transmission path and a fitted correction path of an airborne weather radar beam during airplane take-offs and landings based on initial flight parameters and X-band airborne phased-array weather radar parameters. Errors in an ideal electromagnetic beam propagation path are much greater than those of a fitted path when atmospheric refraction is not considered. The rates of change in the atmospheric refraction index differ with weather conditions and the radar detection angles differ during airplane take-off and landing. Therefore, the airborne radar detection path must be revised in real time according to the specific sounding data and flight parameters. However, an error analysis indicates that a direct linear-fitting method produces significant errors in a negatively refractive atmosphere; a piecewise-fitting method can be adopted to revise the paths according to the actual atmospheric structure. This study provides researchers and practitioners in the aeronautics and astronautics field with updated information regarding the effect of atmospheric refraction on airborne weather radar detection and correction methods.

  13. Differences between wavefront and subjective refraction for infrared light.

    Science.gov (United States)

    Teel, Danielle F W; Jacobs, Robert J; Copland, James; Neal, Daniel R; Thibos, Larry N

    2014-10-01

    To determine the accuracy of objective wavefront refractions for predicting subjective refractions for monochromatic infrared light. Objective refractions were obtained with a commercial wavefront aberrometer (COAS, Wavefront Sciences). Subjective refractions were obtained for 30 subjects with a speckle optometer validated against objective Zernike wavefront refractions on a physical model eye (Teel et al., Design and validation of an infrared Badal optometer for laser speckle, Optom Vis Sci 2008;85:834-42). Both instruments used near-infrared (NIR) radiation (835 nm for COAS, 820 nm for the speckle optometer) to avoid correction for ocular chromatic aberration. A 3-mm artificial pupil was used to reduce complications attributed to higher-order ocular aberrations. For comparison with paraxial (Seidel) and minimum root-mean-square (Zernike) wavefront refractions, objective refractions were also determined for a battery of 29 image quality metrics by computing the correcting lens that optimizes retinal image quality. Objective Zernike refractions were more myopic than subjective refractions for 29 of 30 subjects. The population mean discrepancy was -0.26 diopters (D) (SEM = 0.03 D). Paraxial (Seidel) objective refractions tended to be hyperopically biased (mean discrepancy = +0.20 D, SEM = 0.06 D). Refractions based on retinal image quality were myopically biased for 28 of 29 metrics. The mean bias across all 31 measures was -0.24 D (SEM = 0.03). Myopic bias of objective refractions was greater for eyes with brown irises compared with eyes with blue irises. Our experimental results are consistent with the hypothesis that reflected NIR light captured by the aberrometer originates from scattering sources located posterior to the entrance apertures of cone photoreceptors, near the retinal pigment epithelium. The larger myopic bias for brown eyes suggests that a greater fraction of NIR light is reflected from choroidal melanin in brown eyes compared with blue eyes.

  14. [Correction of refractive errors in patients with strabismus. Part I. Clinical problems associated with refraction, accommodation and convergence].

    Science.gov (United States)

    Tokarz-Sawińska, Ewa

    2012-01-01

    In Part I the problems associated with refraction, accommodation and convergence and their role in proper eye position/visual alignment of the eyes as well as convergent, divergent and vertical alignment of the eyes have been described.

  15. Effect of cycloplegia on the refractive status of children: the Shandong children eye study.

    Directory of Open Access Journals (Sweden)

    Yuan Yuan Hu

    Full Text Available To determine the effect of 1% cyclopentolate on the refractive status of children aged 4 to 18 years.Using a random cluster sampling in a cross-sectional school-based study design, children with an age of 4-18 years were selected from kindergardens, primary schools, junior and senior high schools in a rural county and a city. Auto-refractometry was performed before and after inducing cycloplegia which was achieved by 1% cyclopentolate eye drops.Out of 6364 eligible children, data of 5999 (94.3% children were included in the statistical analysis. Mean age was 10.0±3.3 years (range: 4-18 years. Mean difference between cycloplegic and non-cycloplegic refractive error (DIFF was 0.78±0.79D (median: 0.50D; range: -1.00D to +10.75D. In univariate analysis, DIFF decreased significantly with older age (P<0.001;correlation coefficient r:-0.24, more hyperopic non-cycloplegic refractive error (P<0.001;r = 0.13 and more hyperopic cycloplegic refractive error (P<0.001;r = 0.49. In multivariate analysis, higher DIFF was associated with higher cycloplegic refractive error (P<0.001; standardized regression coefficient beta:0.50; regression coefficient B: 0.19; 95% confidence interval (CI: 0.18, 0.20, followed by lower intraocular pressure (P<0.001; beta: -0.06; B: -0.02; 95%CI: -0.03, -0.01, rural region of habitation (P = 0.001; beta: -0.04; B: -0.07; 95%CI: -0.11, -0.03, and, to a minor degree, with age (P = 0.006; beta: 0.04; B: 0.009; 95%CI: 0.003, 0.016. 66.4% of all eyes with non-cycloplegic myopia (≤-0.50D remained myopic after cycloplegia while the remaining 33.6% of eyes became emmetropic (18.0% or hyperopic (15.7% under cycloplegia. Prevalence of emmetropia decreased from 37.5% before cycloplegia to 19.8% after cycloplegia while the remaining eyes became hyperopic under cycloplegia.The error committed by using non-cycloplegic versus cycloplegic refractometry in children with mid to dark-brown iris color decreased with older age, and in parallel

  16. Quality of vision in refractive and cataract surgery, indirect measurers: review article.

    Science.gov (United States)

    Parede, Taís Renata Ribeira; Torricelli, André Augusto Miranda; Mukai, Adriana; Vieira Netto, Marcelo; Bechara, Samir Jacob

    2013-01-01

    Visual acuity is the measurement of an individual's ability to recognize details of an object in a space. Visual function measurements in clinical ophthalmology are limited by factors such as maximum contrast and so it might not adequately reflect the real vision conditions at that moment as well as the subjective aspects of the world perception by the patient. The objective of a successful vision-restoring surgery lies not only in gaining visual acuity lines, but also in vision quality. Therefore, refractive and cataract surgeries have the responsibility of achieving quality results. It is difficult to define quality of vision by a single parameter, and the main functional-vision tests are: contrast sensitivity, disability glare, intraocular stray light and aberrometry. In the current review the different components of the visual function are explained and the several available methods to assess the vision quality are described.

  17. Compensating for Type-I Errors in Video Quality Assessment

    DEFF Research Database (Denmark)

    Brunnström, Kjell; Tavakoli, Samira; Søgaard, Jacob

    2015-01-01

    This paper analyzes the impact on compensating for Type-I errors in video quality assessment. A Type-I error is to incorrectly conclude that there is an effect. The risk increases with the number of comparisons that are performed in statistical tests. Type-I errors are an issue often neglected...

  18. About the correctness of laser refractive surgery in children

    Directory of Open Access Journals (Sweden)

    V. V. Kurenkov

    2016-01-01

    Full Text Available Disturbances of refraction are one of the most urgent problems of pediatric ophthalmology. Late and incomplete correction of refractive errors leads to the development of amblyopia, disturbances of binocular vision, the appearance of strabismus. Such complications reduce the quality of life, drastically limit the choice of professional child. Pediatric Ophthalmology always face a choice: many drugs and technologies are not approved for use in pediatric patients, practitioners are forced to use their «off-label», but such situations require great care and strict medical indications. For example, refractive surgery has worked well in adults, but its use remains controversial in children for security reasons and unpredictable effects. Several authors have described the use of laser refractive surgery in children under the age of 18 years, but there are no results of a multicenter, controlled study evaluating the safety, efficacy, and especially long-term results. In all the studies, the calculation was performed on adult nomograms ablation, while not proved how they are accurate for children. Long-term results and data on the endothelial cell density, corneal curvature changes in catamnesis are presented no longer than two years. Despite the fact that currently there is insufficient information about the results of remote application keratorefractive laser surgery in children, and there are no indication system and contraindications, modern achievements in medicine should be used in pediatric patients, and our successful track record proves it clearly. Undoubtedly, the positive experience of the laser surgery use in a child with clouding of the cornea in the outcome of herpetic keratitis, which provided a positive result: high visual acuity, binocular vision and lack of infection relapses for 2 years, requires study, evidence multicenter studies, and possibly expansion of indications for refractive laser surgery.

  19. [Use of Plusoptix as a screening method for refractive ambliopia].

    Science.gov (United States)

    Bogdănici, T; Tone, Silvia; Miron, Mihaela; Boboc, Mihaela; Bogdănici, Camelia

    2012-01-01

    Highlighting the differences in the objective refraction using the Plusoptix AO9 comparing them with the refraction performed with TOPCON KR-8900 autorefractor. Prospective study for 3 months held in the Ophthalmology Clinic in Iasi, Hospital Sf. Spiridon on a total of 39 children (21 girls and 18 boys) with mean age of 10.61 +/- 5.67 years. Clinical parameters: sex, age, objective refraction obtained with Plusoptix and with autorefractor corrected visual acuity (with different methods depending on each patient age), ortoptic examination (strabic deviation, binocular vision), the presence of symetry/asymetry while measuring with Plusoptix. The results were statistically processed by F-TEST calculating the correlation coefficient, standard deviation, significance level (using the spherical equivalent of the obtained values). Age limits of the studied cases ranged between 2-23 years. Visual acuity of children who had cooperate was between 0.2-1 with correction, achieving best values on right eye than left eye. 8 cases (20.51%) had large differences between measurements made with Plusoptix and autorefractor, half of that (4 cases) had strabismus. Three of these cases were with small hypermetropia and one with small myopia (Plusoptix shows a lower value). In 2 cases occurred higher differences (about 2-2,5D) between the 2 measurements, in patients with average hypermetropia. Plusoptix refraction was not possible at high hypermetropia or high myopia. This type of determining objective refraction using Plusoptix is a useful method of screening for discovery of refractive errors that can cause refractive amblyopia in young children and in those cases with a difficult collaboration. Because there are differences betweeti this 2 methods, for children with refractive errors are recommended further exploration to determine the appropriate optical correction. Plusoptix is a limited method because it cannot detect the exact values in those cases with high hypermetropia or high

  20. Global Vision Impairment and Blindness Due to Uncorrected Refractive Error, 1990-2010.

    Science.gov (United States)

    Naidoo, Kovin S; Leasher, Janet; Bourne, Rupert R; Flaxman, Seth R; Jonas, Jost B; Keeffe, Jill; Limburg, Hans; Pesudovs, Konrad; Price, Holly; White, Richard A; Wong, Tien Y; Taylor, Hugh R; Resnikoff, Serge

    2016-03-01

    The purpose of this systematic review was to estimate worldwide the number of people with moderate and severe visual impairment (MSVI; presenting visual acuity blindness (presenting visual acuity blind (7.9% increase from 1990) and 101.2 million (95% CI: 87.88-125.5 million) vision impaired due to URE (15% increase since 1990), while the global population increased by 30% (1990-2010). The all-age age-standardized prevalence of URE blindness decreased 33% from 0.2% (95% CI: 0.1-0.2%) in 1990 to 0.1% (95% CI: 0.1-0.1%) in 2010, whereas the prevalence of URE MSVI decreased 25% from 2.1% (95% CI: 1.6-2.4%) in 1990 to 1.5% (95% CI: 1.3-1.9%) in 2010. In 2010, URE contributed 20.9% (95% CI: 15.2-25.9%) of all blindness and 52.9% (95% CI: 47.2-57.3%) of all MSVI worldwide. The contribution of URE to all MSVI ranged from 44.2 to 48.1% in all regions except in South Asia which was at 65.4% (95% CI: 62-72%). : We conclude that in 2010, uncorrected refractive error continues as the leading cause of vision impairment and the second leading cause of blindness worldwide, affecting a total of 108 million people or 1 in 90 persons.

  1. Comparing sports vision among three groups of soft tennis adolescent athletes: Normal vision, refractive errors with and without correction

    Directory of Open Access Journals (Sweden)

    Shih-Tsun Chang

    2015-01-01

    Full Text Available Background: The effect of correcting static vision on sports vision is still not clear. Aim: To examine whether sports vision (depth perception [DP], dynamic visual acuity [DVA], eye movement [EM], peripheral vision [PV], and momentary vision [MV], were different among soft tennis adolescent athletes with normal vision (Group A, with refractive error and corrected with (Group B and without eyeglasses (Group C. Setting and Design: A cross-section study was conducted. Soft tennis athletes aged 10–13 who played softball tennis for 2–5 years, and who were without any ocular diseases and without visual training for the past 3 months were recruited. Materials and Methods: DPs were measured in an absolute deviation (mm between a moving rod and fixing rod (approaching at 25 mm/s, receding at 25 mm/s, approaching at 50 mm/s, receding at 50 mm/s using electric DP tester. A smaller deviation represented better DP. DVA, EM, PV, and MV were measured on a scale from 1 (worse to 10 (best using ATHLEVISION software. Statistical Analysis: Chi-square test and Kruskal–Wallis test was used to compare the data among the three study groups. Results: A total of 73 athletes (37 in Group A, 8 in Group B, 28 in Group C were enrolled in this study. All four items of DP showed significant difference among the three study groups (P = 0.0051, 0.0004, 0.0095, 0.0021. PV displayed significant difference among the three study groups (P = 0.0044. There was no significant difference in DVA, EM, and MV among the three study groups. Conclusions: Significant better DP and PV were seen among soft tennis adolescent athletes with normal vision than those with refractive error regardless whether they had eyeglasses corrected. On the other hand, DVA, EM, and MV were similar among the three study groups.

  2. Precision measurements of gas refractivity by means of a Fabry-Perot interferometer illustrated by the monitoring of radiator refractivity in the DELPHI RICH detectors

    CERN Document Server

    Filippas-Tassos, A; Fokitis, E; Maltezos, S; Patrinos, K

    2002-01-01

    With an updated, flexible, highly efficient and easily installed system we obtained accurate refractivity (n-1) values. This system is a refractometer based on a Fabry-Perot interferometer and was used to monitor the refractivity of DELPHI RICH Cherenkov radiators near the VUV region. By using a Pt-Ne spectral lamp and improved alignment and temperature control, the refractivities of C//5F//1//2 and C//4F//1 //0 have been monitored since 1996. With this light source, selected to have large coherence lengths, we can extract the refractivity at several wavelengths from one data set only. The estimated errors of the refractivity measurements are less than 1.2%, and depend on wavelength and the type of gas used. The various parameters affecting the accuracy of the refractometer are also discussed. Finally, results from special sample refractivity measurements of the liquid radiator (C//6F//1//4) in its gas phase, are presented.

  3. Refraction and Ocular Biometry of Preschool Children in Shanghai, China.

    Science.gov (United States)

    Zhang, Luoli; He, Xiangui; Qu, Xiaomei; You, Xiaofang; Wang, Bingjie; Shi, Huijing; Tan, Hui; Zou, Haidong; Zhu, Jianfeng

    2018-01-01

    To investigate the refraction and ocular biometry characteristics and to examine the prevalence of refractive errors in preschool children aged 3 to 6 years in Shanghai, China. A school-based cross-sectional study was conducted in Jiading and Xuhui District, Shanghai, in 2013. We randomly selected 7 kindergartens in Jiading District and 10 kindergartens in Xuhui District, with a probability proportionate to size. The children underwent comprehensive eye examinations, including cycloplegic refraction and biometric measurements. Myopia, hyperopia, astigmatism were defined as spherical equivalent (SE) ≤ -0.50 D, SE ≥ +2.00 D, and cylindrical diopters ≤ -1.00 D. The mean SE for 3- to 6-year-old children was +1.20 D (standard deviation [SD] 1.05), and the mean axial length (AL) was 22.29 mm (SD 0.73). The overall prevalence of myopia and astigmatism was 3.7% and 18.3%, respectively. No difference in prevalence of astigmatism was found across age groups. There was a statistically significant association between lower cylindrical diopters and higher spherical diopters (Spearman's correlation: -0.21, P < 0.001). Chinese children aged 3 to 6 years in the Shanghai area were mostly mildly hyperopic, with a low prevalence of myopia. Refractive astigmatism for children may be relatively stable throughout the preschool stage. Astigmatism was significantly associated with refractive error.

  4. Global Calibration of Multi-Cameras Based on Refractive Projection and Ray Tracing

    Directory of Open Access Journals (Sweden)

    Mingchi Feng

    2017-10-01

    Full Text Available Multi-camera systems are widely applied in the three dimensional (3D computer vision, especially when multiple cameras are distributed on both sides of the measured object. The calibration methods of multi-camera systems are critical to the accuracy of vision measurement and the key is to find an appropriate calibration target. In this paper, a high-precision camera calibration method for multi-camera systems based on transparent glass checkerboards and ray tracing is described, and is used to calibrate multiple cameras distributed on both sides of the glass checkerboard. Firstly, the intrinsic parameters of each camera are obtained by Zhang’s calibration method. Then, multiple cameras capture several images from the front and back of the glass checkerboard with different orientations, and all images contain distinct grid corners. As the cameras on one side are not affected by the refraction of glass checkerboard, extrinsic parameters can be directly calculated. However, the cameras on the other side are influenced by the refraction of glass checkerboard, and the direct use of projection model will produce a calibration error. A multi-camera calibration method using refractive projection model and ray tracing is developed to eliminate this error. Furthermore, both synthetic and real data are employed to validate the proposed approach. The experimental results of refractive calibration show that the error of the 3D reconstruction is smaller than 0.2 mm, the relative errors of both rotation and translation are less than 0.014%, and the mean and standard deviation of reprojection error of the four-camera system are 0.00007 and 0.4543 pixels, respectively. The proposed method is flexible, highly accurate, and simple to carry out.

  5. Exceptionally low prevalence of refractive error and visual impairment in schoolchildren from Lao People's Democratic Republic.

    Science.gov (United States)

    Casson, Robert J; Kahawita, Shyalle; Kong, Aimee; Muecke, James; Sisaleumsak, Siphetthavong; Visonnavong, Vithoune

    2012-10-01

    Vientiane Province is an urbanizing region in Southeast Asia. We aimed to determine the prevalence of refractive error and visual impairment in primary school-aged children in this region. Prospective, cross-sectional survey. A total of 2899 schoolchildren from Vientiane Province, Lao People's Democratic Republic (Lao PDR). Ten districts from Vientiane were randomly selected and 2 primary schools were randomly selected from each district. All children aged 6 to 11 years at selected schools were eligible to participate. The examination included visual acuity (VA) testing, cycloplegic retinoscopy with subjective refinement if indicated, ocular motility testing, and anterior segment and fundus examinations in visually impaired children. Cycloplegic refraction and VA. There was an estimated total of 3330 children who were eligible to participate, and data were recorded from 2899 (87%) of these children. Complete refractive data were available on 2842 children (85% of eligible population). The mean spherical equivalent (SE) in the right eyes was +0.60 diopter (D) (95% confidence interval [CI], 0.49-0.72), and the mean SE in the left eyes was +0.59 (95% CI, 0.50-0.68). The prevalence of hyperopia was 2.8% (95% CI, 1.9-3.7; 88 subjects), and the prevalence of myopia was 0.8% (95% CI, 0.3-1.4; 24 subjects). The majority of children (98%; 95% CI, 97.0-99.0) had normal unaided binocular VA (at least 20/32 in their better eye). The overall prevalence of any visual impairment (presenting VA <20/32 in the better eye) was 1.9% (95% CI, 1.0-2.9; 55 subjects). In multivariate logistic regression analysis, age (P = 0.001) was a significant predictor, and female gender (P = 0.08) and Yao ethnicity (P = 0.09) were borderline significant predictors of the presence of any visual impairment. Visual impairment is not a public health concern in this primary school-aged population; however, visually impaired children in the community were not studied. From this baseline, future surveys

  6. Refractive Status at Birth: Its Relation to Newborn Physical Parameters at Birth and Gestational Age

    Science.gov (United States)

    Varghese, Raji Mathew; Sreenivas, Vishnubhatla; Puliyel, Jacob Mammen; Varughese, Sara

    2009-01-01

    Background Refractive status at birth is related to gestational age. Preterm babies have myopia which decreases as gestational age increases and term babies are known to be hypermetropic. This study looked at the correlation of refractive status with birth weight in term and preterm babies, and with physical indicators of intra-uterine growth such as the head circumference and length of the baby at birth. Methods All babies delivered at St. Stephens Hospital and admitted in the nursery were eligible for the study. Refraction was performed within the first week of life. 0.8% tropicamide with 0.5% phenylephrine was used to achieve cycloplegia and paralysis of accommodation. 599 newborn babies participated in the study. Data pertaining to the right eye is utilized for all the analyses except that for anisometropia where the two eyes were compared. Growth parameters were measured soon after birth. Simple linear regression analysis was performed to see the association of refractive status, (mean spherical equivalent (MSE), astigmatism and anisometropia) with each of the study variables, namely gestation, length, weight and head circumference. Subsequently, multiple linear regression was carried out to identify the independent predictors for each of the outcome parameters. Results Simple linear regression showed a significant relation between all 4 study variables and refractive error but in multiple regression only gestational age and weight were related to refractive error. The partial correlation of weight with MSE adjusted for gestation was 0.28 and that of gestation with MSE adjusted for weight was 0.10. Birth weight had a higher correlation to MSE than gestational age. Conclusion This is the first study to look at refractive error against all these growth parameters, in preterm and term babies at birth. It would appear from this study that birth weight rather than gestation should be used as criteria for screening for refractive error, especially in developing

  7. Refractive status at birth: its relation to newborn physical parameters at birth and gestational age.

    Directory of Open Access Journals (Sweden)

    Raji Mathew Varghese

    Full Text Available Refractive status at birth is related to gestational age. Preterm babies have myopia which decreases as gestational age increases and term babies are known to be hypermetropic. This study looked at the correlation of refractive status with birth weight in term and preterm babies, and with physical indicators of intra-uterine growth such as the head circumference and length of the baby at birth.All babies delivered at St. Stephens Hospital and admitted in the nursery were eligible for the study. Refraction was performed within the first week of life. 0.8% tropicamide with 0.5% phenylephrine was used to achieve cycloplegia and paralysis of accommodation. 599 newborn babies participated in the study. Data pertaining to the right eye is utilized for all the analyses except that for anisometropia where the two eyes were compared. Growth parameters were measured soon after birth. Simple linear regression analysis was performed to see the association of refractive status, (mean spherical equivalent (MSE, astigmatism and anisometropia with each of the study variables, namely gestation, length, weight and head circumference. Subsequently, multiple linear regression was carried out to identify the independent predictors for each of the outcome parameters.Simple linear regression showed a significant relation between all 4 study variables and refractive error but in multiple regression only gestational age and weight were related to refractive error. The partial correlation of weight with MSE adjusted for gestation was 0.28 and that of gestation with MSE adjusted for weight was 0.10. Birth weight had a higher correlation to MSE than gestational age.This is the first study to look at refractive error against all these growth parameters, in preterm and term babies at birth. It would appear from this study that birth weight rather than gestation should be used as criteria for screening for refractive error, especially in developing countries where the

  8. The economics of health care quality and medical errors.

    Science.gov (United States)

    Andel, Charles; Davidow, Stephen L; Hollander, Mark; Moreno, David A

    2012-01-01

    Hospitals have been looking for ways to improve quality and operational efficiency and cut costs for nearly three decades, using a variety of quality improvement strategies. However, based on recent reports, approximately 200,000 Americans die from preventable medical errors including facility-acquired conditions and millions may experience errors. In 2008, medical errors cost the United States $19.5 billion. About 87 percent or $17 billion were directly associated with additional medical cost, including: ancillary services, prescription drug services, and inpatient and outpatient care, according to a study sponsored by the Society for Actuaries and conducted by Milliman in 2010. Additional costs of $1.4 billion were attributed to increased mortality rates with $1.1 billion or 10 million days of lost productivity from missed work based on short-term disability claims. The authors estimate that the economic impact is much higher, perhaps nearly $1 trillion annually when quality-adjusted life years (QALYs) are applied to those that die. Using the Institute of Medicine's (IOM) estimate of 98,000 deaths due to preventable medical errors annually in its 1998 report, To Err Is Human, and an average of ten lost years of life at $75,000 to $100,000 per year, there is a loss of $73.5 billion to $98 billion in QALYs for those deaths--conservatively. These numbers are much greater than those we cite from studies that explore the direct costs of medical errors. And if the estimate of a recent Health Affairs article is correct-preventable death being ten times the IOM estimate-the cost is $735 billion to $980 billion. Quality care is less expensive care. It is better, more efficient, and by definition, less wasteful. It is the right care, at the right time, every time. It should mean that far fewer patients are harmed or injured. Obviously, quality care is not being delivered consistently throughout U.S. hospitals. Whatever the measure, poor quality is costing payers and

  9. Investigation of the refractive status of preschool children in Xiantao, Hubei Province

    OpenAIRE

    Nian Guan; Hao-Ming Chen; Zhi-Guang Hu

    2014-01-01

    AIM: To investigate the refractive status of the preschool children in Xiantao, Hubei Province in order to find out the abnormal refraction error beyond the physiological range. METHODS: In this cross-sectional study, we investigated preschool children in kindergartens and the scattered ones were 12 716(25 432 eyes)ranging from 6mo~6 years old. 1 581 children(3 162 eyes)were diagnosed ametropia by Suresight refractive screening instrument, which were confirmed again after mydriasis optometry....

  10. Spherical equivalent refractive error in preschool children from a population with a high prevalence of astigmatism.

    Science.gov (United States)

    Dobson, Velma; Harvey, Erin M; Miller, Joseph M

    2007-02-01

    To describe spherical equivalent (sph eq) refractive errors in preschool members of a Native American tribe with a high prevalence of astigmatism. Cycloplegic autorefraction measurements were obtained for 819 three- and four-year-old Tohono O'odham children, with follow-up measurements in 146 after 4 to 8 years. Mean sph eq was significantly more hyperopic in the astigmatic group than in the non-astigmatic group (1.24 vs. 0.87 D). At follow-up, prevalence of hyperopic sph eq and hyperopic astigmatism had significantly decreased, and prevalence of emmetropic/myopic sph eq and myopic astigmatism had significantly increased. The decrease in mean sph eq was similar in astigmats and non-astigmats. Astigmatism did not change over time. Most preschool children in this highly astigmatic population are hyperopic, with astigmats showing higher mean hyperopic sph eq than non-astigmats. Astigmats and non-astigmats show a similar decrease in amount of hyperopic sph eq over follow-up of 4 to 8 years.

  11. Fabrication Quality Analysis of a Fiber Optic Refractive Index Sensor Created by CO2 Laser Machining

    Directory of Open Access Journals (Sweden)

    Wei-Te Wu

    2013-03-01

    Full Text Available This study investigates the CO2 laser-stripped partial cladding of silica-based optic fibers with a core diameter of 400 μm, which enables them to sense the refractive index of the surrounding environment. However, inappropriate treatments during the machining process can generate a number of defects in the optic fiber sensors. Therefore, the quality of optic fiber sensors fabricated using CO2 laser machining must be analyzed. The results show that analysis of the fiber core size after machining can provide preliminary defect detection, and qualitative analysis of the optical transmission defects can be used to identify imperfections that are difficult to observe through size analysis. To more precisely and quantitatively detect fabrication defects, we included a tensile test and numerical aperture measurements in this study. After a series of quality inspections, we proposed improvements to the existing CO2 laser machining parameters, namely, a vertical scanning pathway, 4 W of power, and a feed rate of 9.45 cm/s. Using these improved parameters, we created optical fiber sensors with a core diameter of approximately 400 μm, no obvious optical transmission defects, a numerical aperture of 0.52 ± 0.019, a 0.886 Weibull modulus, and a 1.186 Weibull-shaped parameter. Finally, we used the optical fiber sensor fabricated using the improved parameters to measure the refractive indices of various solutions. The results show that a refractive-index resolution of 1.8 × 10−4 RIU (linear fitting R2 = 0.954 was achieved for sucrose solutions with refractive indices ranging between 1.333 and 1.383. We also adopted the particle plasmon resonance sensing scheme using the fabricated optical fibers. The results provided additional information, specifically, a superior sensor resolution of 5.73 × 10−5 RIU, and greater linearity at R2 = 0.999.

  12. Influence factors of visual quality after phacoemulsification for cataract

    Directory of Open Access Journals (Sweden)

    Zhen-Lin Lin

    2017-12-01

    Full Text Available Cataract refers to the degenerative changes in lens quality caused by various causes of reduced transparency or color change. Surgical treatment is the main treatment modality at present. Among them, phacoemulsification has become the main surgical treatment for cataract because of its advantages such as short operation time, small incision and quicker healing. Today, cataract surgery has gradually shift to refractive surgery, and is no longer simply as cataract surgery. But after cataract phacoemulsification, the symptoms and visual quality are different. The main causes include refractive error, postoperative dry eyes and postoperative corneal astigmatism. This article reviews the factors that influence the visual quality of cataract phacoemulsification and its future trends.

  13. Refraction corrected calibration for aquatic locomotion research: application of Snell's law improves spatial accuracy

    NARCIS (Netherlands)

    Henrion, S.; Spoor, C.W.; Pieters, R.P.M.; Müller, U.K.; Leeuwen, van J.L.

    2015-01-01

    Images of underwater objects are distorted by refraction at the water–glass–air interfaces and these distortions can lead to substantial errors when reconstructing the objects' position and shape. So far, aquatic locomotion studies have minimized refraction in their experimental setups and used the

  14. Effect of Cycloplegia on Corneal Biometrics and Refractive State.

    Science.gov (United States)

    Bagheri, Abbas; Feizi, Mohadeseh; Shafii, Aliakbar; Faramarzi, Amir; Tavakoli, Mehdi; Yazdani, Shahin

    2018-01-01

    To determine changes in refractive state and corneal parameters after cycloplegia with cyclopentolate hydrochloride 1% using a dual Scheimpflug imaging system. In this prospective cross-sectional study patients aged 10 to 40 years who were referred for optometric evaluation enrolled and underwent autorefraction and corneal imaging with the Galilei dual Scheimpflug system before and 30 minutes after twice instillation of medication. Changes in refraction and astigmatism were investigated. Corneal biometrics including anterior and posterior corneal curvatures, total corneal power and corneal pachymetry were compared before and after cycloplegia. Two hundred and twelve eyes of 106 subjects with mean age of 28 ± 5 years including 201 myopic and 11 hyperopic eyes were evaluated. Mean spherical equivalent refractive error before cycloplegia was -3.4 ± 2.6 D. A mean hyperopic shift of 0.4 ± 0.5 D occurred after cycloplegia ( P biometrics should be considered before cataract and refractive surgeries.

  15. Analysis of refractive state in 708 children with ametropic amblyopia

    Directory of Open Access Journals (Sweden)

    Ju-Fen Huang

    2016-01-01

    Full Text Available AIM: To analyze the refractive state and explore the epidemiologic feature of children with ametropic amblyopia.METHODS: This study retrospectively analyzed 708 children(1 416 eyeswith amblyopia from January 2012 to December 2013 in Special Department of Strabismus and Amblyopic and Department of Pediatric Ophthalmology in our hospital, who were diagnosed as ametropic amblyopia and accepted centrally comprehensive training. The refractive state were given epidemiologic analyze.RESULTS: In the 708 cases(1 416 eyes, there were 190 eyes with hyperopia(13.42%,612 eyes with hyperopia astigmatism(43.22%,18 eyes with myopia(1.27%,134 eyes with myopia astigmatism(9.46%,462 eyes with mixed astigmatism(32.63%. The distributions of refractive state in children at different age were different, and the difference was statistically significant(PCONCLUSION: Hyperopia ametropia and mixed astigmatism are the main types of refractive errors in amblyopia children. The level of amblyopia is related to refractive state and astigmatism axial.

  16. Relationship between surface tension and refractive index in binary non-electrolyte mixtures

    International Nuclear Information System (INIS)

    Acevedo, I.L.; Pedrosa, G.C.; Katz, M.

    1990-01-01

    Lorentz-Lorenz equation for molecular refraction has been combined with Sugden's parachor equation for binary non-electrolyte mixtures at 298.15 K. The obtained equation has been shown successful in calculating values of surface tensions, by measuring refractive indices of the binary mixtures at the same mole fractions. The estimated error decreases when the mixtures present possible isorefractives. (Author) [es

  17. Human resources for refraction services in Central Nepal.

    Science.gov (United States)

    Kandel, Himal; Murthy, G V S; Bascaran, Covadonga

    2015-07-01

    Uncorrected refractive error is a public health problem globally and in Nepal. Planning of refraction services is hampered by a paucity of data. This study was conducted to determine availability and distribution of human resources for refraction, their efficiency, the type and extent of their training; the current service provision of refraction services and the unmet need in human resources for refraction in Central Nepal. This was a descriptive cross-sectional study. All refraction facilities in the Central Region were identified through an Internet search and interviews of key informants from the professional bodies and parent organisations of primary eye centres. A stratified simple random sampling technique was used to select 50 per cent of refraction facilities. The selected facilities were visited for primary data collection. Face-to-face interviews were conducted with the managers and the refractionists available in the facilities using a semi-structured questionnaire. Data was collected in 29 centres. All the managers (n=29; response rate 100 per cent) and 50 refractionists (Response rate 65.8 per cent) were interviewed. Optometrists and ophthalmic assistants were the main providers of refraction services (n=70, 92.11 per cent). They were unevenly distributed across the region, highly concentrated around urban areas. The median number of refractions per refractionist per year was 3,600 (IQR: 2,400 - 6,000). Interviewed refractionists stated that clients' knowledge, attitude and practice related factors such as lack of awareness of the need for refraction services and/or availability of existing services were the major barriers to the output of refraction services. The total number of refractions carried out in the Central Region per year was 653,176. An additional 170 refractionists would be needed to meet the unmet need of 1,323,234 refractions. The study findings demand a major effort to develop appropriately trained personnel when planning

  18. Changes in refractive characteristics in Japanese children with Down syndrome.

    Science.gov (United States)

    Horio, Junna; Kaneko, Hiroki; Takayama, Kei; Tuzuki, Kinichi; Kakihara, Hiroko; Iwami, Miou; Kawase, Yoshikatsu; Tsunekawa, Taichi; Yamaguchi, Naoko; Nonobe, Norie; Terasaki, Hiroko

    2018-03-01

    To investigate the refractive characteristics of Japanese children with Down syndrome. Retrospective study. The clinical records of refractive errors and ocular manifestations in children with Down syndrome who visited the Aichi Children's Health and Medical Center between November 2001 and January 2016 were retrospectively reviewed. The children were divided into the 3 following groups depending on their age: group 1 (≤ 6 years), group 2 (7-12 years), and group 3 (13-19 years). The collection of refractive error data was performed only for the right eyes and only once for each child, when the children were last examined with their pupils dilated. The study included 416 children (224 boys, 192 girls; average age, 6.1 ± 4.1 years). Group 3 had significantly stronger myopia than did groups 1 and 2. The mean cylindrical power in all the children was - 2.1 ± 1.2 diopters (D), and cylindrical power ≤ - 1.0 D (stronger than - 1.0 D) was seen in 366 eyes (88%). No significant difference in cylindrical power was found among the 3 groups. The spherical equivalent refraction showed an age-dependent myopic shift. Given that the amount of astigmatism did not show age-dependent differences, the age-dependent myopic shift could be due mainly to the change in spherical power.

  19. Simultaneous refractive index and thickness measurement with the transmission interferometric adsorption sensor

    Energy Technology Data Exchange (ETDEWEB)

    Sannomiya, Takumi; Voeroes, Janos [Laboratory of Biosensors and Bioelectronics, Department of Information Technology and Electrical Engineering, ETH Zurich, 8092, Zurich (Switzerland); Balmer, Tobias E [Materials Research Center, ETH Zurich, 8093, Zurich (Switzerland); Heuberger, Manfred, E-mail: sannomiya@biomed.ee.ethz.c, E-mail: tobias.balmer@mat.ethz.c, E-mail: manfred.heuberger@empa.c, E-mail: janos.voros@biomed.ee.ethz.c [Laboratory for Surface Science and Technology, Department of Materials, ETH Zurich, 8093, Zurich (Switzerland)

    2010-10-13

    Refractive index and thickness of the adlayer are determined simultaneously using the transmission interferometric adsorption sensor (TInAS). Optical biosensors, where both refractive index and thickness of a homogeneous adlayer (thus the adsorbed mass) are determined simultaneously, so-called model-free biosensors, are important tools to investigate the adsorbed mass of biomolecules with unknown conformation. Our proposed calculation method enables model-free biosensing from a single spectrum acquired by a simple TInAS setup, namely using information of peak/dip positions as well as peak/dip intensities. The feasibility of this method was experimentally tested by adsorbing polyelectrolyte multilayer as well as biomolecules. To validate the new method also for the more intricate heterogeneous adlayer, the apparent refractive index and thickness were assessed theoretically by simulating a selection of different adsorbate configurations with the multiple multipole program (MMP). We found that a lateral inhomogeneity of the adsorbate (e.g. islands or adsorbed colloids) results in correct thickness and in reduced refractive index averaged in proportion to their density while vertically inhomogeneous density caused more complex responses. However, the apparent mass was always correct. Measurement errors can lead to significant errors in the apparent refractive index, particularly when the adlayer is very thin (<5 nm). This model-free TInAS technique would be useful not only for the measurement of adsorbed mass but also for the conformational analysis of the adsorbed molecules.

  20. Influence of corneal asphericity on the refractive outcome of intraocular lens implantation in cataract surgery.

    Science.gov (United States)

    Savini, Giacomo; Hoffer, Kenneth J; Barboni, Piero

    2015-04-01

    To evaluate the possible influence of anterior corneal surface asphericity on the refractive outcomes in eyes having intraocular lens (IOL) implantation after cataract surgery. Fondazione G.B. Bietti IRCCS, Rome, Italy. Retrospective comparative case series. Intraocular lens power was calculated using the Haigis, Hoffer Q, Holladay 1, and SRK/T formulas. Asphericity (Q-value) was measured at 8.0 mm with a Placido-disk corneal topographer (Keratron), a rotating Scheimpflug camera (Pentacam), and a rotating Scheimpflug camera combined with Placido-disk corneal topography (Sirius). The relationship between the error in refraction prediction (ie, difference between expected refraction and refraction measured 1 month after surgery) and the Q-value was assessed by linear regression. The same IOL model (Acrysof SA60AT) was implanted in 115 eyes of 115 consecutive patients. Regression analysis showed a statistically significant relationship between the error in refraction prediction and the Q-value with all formulas and all devices. In all cases, a more negative Q-value (prolate cornea) was associated with a myopic outcome, whereas a more positive Q-value (oblate cornea) was associated with a hyperopic outcome. The highest coefficient of determination was detected between the Hoffer Q formula and the Placido-disk corneal topographer (R(2) = 0.2630), for which the error in refraction prediction (y) was related to the Q-value (x) according to the formula y = -0.2641 + 1.4589 × x. Corneal asphericity influences the refractive outcomes of IOL implantation and should be taken into consideration when using third-generation IOL power formulas. Dr. Hoffer receives book royalties from Slack, Inc., Thorofare, New Jersey, and formula royalties from all manufacturers using the Hoffer Q formula. No other author has a financial or proprietary interest in any material or method mentioned. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  1. Error Budget for a Calibration Demonstration System for the Reflected Solar Instrument for the Climate Absolute Radiance and Refractivity Observatory

    Science.gov (United States)

    Thome, Kurtis; McCorkel, Joel; McAndrew, Brendan

    2013-01-01

    A goal of the Climate Absolute Radiance and Refractivity Observatory (CLARREO) mission is to observe highaccuracy, long-term climate change trends over decadal time scales. The key to such a goal is to improving the accuracy of SI traceable absolute calibration across infrared and reflected solar wavelengths allowing climate change to be separated from the limit of natural variability. The advances required to reach on-orbit absolute accuracy to allow climate change observations to survive data gaps exist at NIST in the laboratory, but still need demonstration that the advances can move successfully from to NASA and/or instrument vendor capabilities for spaceborne instruments. The current work describes the radiometric calibration error budget for the Solar, Lunar for Absolute Reflectance Imaging Spectroradiometer (SOLARIS) which is the calibration demonstration system (CDS) for the reflected solar portion of CLARREO. The goal of the CDS is to allow the testing and evaluation of calibration approaches, alternate design and/or implementation approaches and components for the CLARREO mission. SOLARIS also provides a test-bed for detector technologies, non-linearity determination and uncertainties, and application of future technology developments and suggested spacecraft instrument design modifications. The resulting SI-traceable error budget for reflectance retrieval using solar irradiance as a reference and methods for laboratory-based, absolute calibration suitable for climatequality data collections is given. Key components in the error budget are geometry differences between the solar and earth views, knowledge of attenuator behavior when viewing the sun, and sensor behavior such as detector linearity and noise behavior. Methods for demonstrating this error budget are also presented.

  2. Determination of the refractive index of dehydrated cells by means of digital holographic microscopy

    Science.gov (United States)

    Belashov, A. V.; Zhikhoreva, A. A.; Bespalov, V. G.; Vasyutinskii, O. S.; Zhilinskaya, N. T.; Novik, V. I.; Semenova, I. V.

    2017-10-01

    Spatial distributions of the integral refractive index in dehydrated cells of human oral cavity epithelium are obtained by means of digital holographic microscopy, and mean refractive index of the cells is determined. The statistical analysis of the data obtained is carried out, and absolute errors of the method are estimated for different experimental conditions.

  3. Fully 3D refraction correction dosimetry system

    International Nuclear Information System (INIS)

    Manjappa, Rakesh; Makki, S Sharath; Kanhirodan, Rajan; Kumar, Rajesh; Vasu, Ram Mohan

    2016-01-01

    The irradiation of selective regions in a polymer gel dosimeter results in an increase in optical density and refractive index (RI) at those regions. An optical tomography-based dosimeter depends on rayline path through the dosimeter to estimate and reconstruct the dose distribution. The refraction of light passing through a dose region results in artefacts in the reconstructed images. These refraction errors are dependant on the scanning geometry and collection optics. We developed a fully 3D image reconstruction algorithm, algebraic reconstruction technique-refraction correction (ART-rc) that corrects for the refractive index mismatches present in a gel dosimeter scanner not only at the boundary, but also for any rayline refraction due to multiple dose regions inside the dosimeter. In this study, simulation and experimental studies have been carried out to reconstruct a 3D dose volume using 2D CCD measurements taken for various views. The study also focuses on the effectiveness of using different refractive-index matching media surrounding the gel dosimeter. Since the optical density is assumed to be low for a dosimeter, the filtered backprojection is routinely used for reconstruction. We carry out the reconstructions using conventional algebraic reconstruction (ART) and refractive index corrected ART (ART-rc) algorithms. The reconstructions based on FDK algorithm for cone-beam tomography has also been carried out for comparison. Line scanners and point detectors, are used to obtain reconstructions plane by plane. The rays passing through dose region with a RI mismatch does not reach the detector in the same plane depending on the angle of incidence and RI. In the fully 3D scanning setup using 2D array detectors, light rays that undergo refraction are still collected and hence can still be accounted for in the reconstruction algorithm. It is found that, for the central region of the dosimeter, the usable radius using ART-rc algorithm with water as RI matched

  4. Fully 3D refraction correction dosimetry system.

    Science.gov (United States)

    Manjappa, Rakesh; Makki, S Sharath; Kumar, Rajesh; Vasu, Ram Mohan; Kanhirodan, Rajan

    2016-02-21

    The irradiation of selective regions in a polymer gel dosimeter results in an increase in optical density and refractive index (RI) at those regions. An optical tomography-based dosimeter depends on rayline path through the dosimeter to estimate and reconstruct the dose distribution. The refraction of light passing through a dose region results in artefacts in the reconstructed images. These refraction errors are dependant on the scanning geometry and collection optics. We developed a fully 3D image reconstruction algorithm, algebraic reconstruction technique-refraction correction (ART-rc) that corrects for the refractive index mismatches present in a gel dosimeter scanner not only at the boundary, but also for any rayline refraction due to multiple dose regions inside the dosimeter. In this study, simulation and experimental studies have been carried out to reconstruct a 3D dose volume using 2D CCD measurements taken for various views. The study also focuses on the effectiveness of using different refractive-index matching media surrounding the gel dosimeter. Since the optical density is assumed to be low for a dosimeter, the filtered backprojection is routinely used for reconstruction. We carry out the reconstructions using conventional algebraic reconstruction (ART) and refractive index corrected ART (ART-rc) algorithms. The reconstructions based on FDK algorithm for cone-beam tomography has also been carried out for comparison. Line scanners and point detectors, are used to obtain reconstructions plane by plane. The rays passing through dose region with a RI mismatch does not reach the detector in the same plane depending on the angle of incidence and RI. In the fully 3D scanning setup using 2D array detectors, light rays that undergo refraction are still collected and hence can still be accounted for in the reconstruction algorithm. It is found that, for the central region of the dosimeter, the usable radius using ART-rc algorithm with water as RI matched

  5. Effect of surface plasmon polaritons on the sensitivity of refractive index measurement using total internal reflection method

    International Nuclear Information System (INIS)

    Roshan Entezar, S.

    2015-01-01

    The phase difference between two p-polarized and s-polarized plane waves which are reflected under total internal reflection from the base of a prism with a thin metal coating is studied. Typically such a quantity can be used to measure the refractive index of a test material using the total internal reflection method. It is shown that due to the excitation of surface plasmon polaritons at the interface between the tested dielectric material and the thin metal layer, the p-polarized light experiences a large phase shift which enlarges the phase difference between the p-polarized and the s-polarized waves. As a result, the sensitivity of refractive index measurement increases and the error in determining the refractive index decreases. - Highlights: • Phase difference of totally internally reflected p and s polarized beams is studied. • Excitation of the surface wave increases the phase shift of the p-polarized light. • The sensitivity of refractive index measurement increases by using a coated prism. • The error in determining the refractive index decreases using the coated prism

  6. Myopia, spectacle wear, and risk of bicycle accidents among rural Chinese secondary school students: the Xichang Pediatric Refractive Error Study report no. 7.

    Science.gov (United States)

    Zhang, Mingzhi; Congdon, Nathan; Li, Liping; Song, Yue; Choi, Kai; Wang, Yunfei; Zhou, Zhongxia; Liu, Xiaojian; Sharma, Abhishek; Chen, Weihong; Lam, Dennis S C

    2009-06-01

    To study the effect of myopia and spectacle wear on bicycle-related injuries in rural Chinese students. Myopia is common among Chinese students but few studies have examined its effect on daily activities. Data on visual acuity, refractive error, current spectacle wear, and history of bicycle use and accidents during the past 3 years were sought from 1891 students undergoing eye examinations in rural Guangdong province. Refractive and accident data were available for 1539 participants (81.3%), among whom the mean age was 14.6 years, 52.5% were girls, 26.8% wore glasses, and 12.9% had myopia of less than -4 diopters in both eyes. More than 90% relied on bicycles to get to school daily. A total of 2931 accidents were reported by 423 participants, with 68 requiring medical attention. Male sex (odds ratio, 1.55; P accident, but habitual visual acuity and myopia were unassociated with the crash risk, after adjusting for age, sex, time spent riding, and risky riding behaviors. These results may be consistent with data on motor vehicle accidents implicating peripheral vision (potentially compromised by spectacle wear) more strongly than central visual acuity in mediating crash risk.

  7. Refractive index contrast in porous silicon multilayers

    Energy Technology Data Exchange (ETDEWEB)

    Nava, R.; Mora, M.B. de la; Tagueena-Martinez, J. [Centro de Investigacion en Energia, Universidad Nacional Autonoma de Mexico, Temixco, Morelos (Mexico); Rio, J.A. del [Centro de Investigacion en Energia, Universidad Nacional Autonoma de Mexico, Temixco, Morelos (Mexico); Centro Morelense de Innovacion y Transferencia Tecnologica, Consejo de Ciencia y Tecnologia del Estado de Morelos (Mexico)

    2009-07-15

    Two of the most important properties of a porous silicon multilayer for photonic applications are flat interfaces and a relative large refractive index contrast between layers in the optical wavelength range. In this work, we studied the effect of the current density and HF electrolyte concentration on the refractive index of porous silicon. With the purpose of increasing the refractive index contrast in a multilayer, the refractive index of porous silicon produced at low current was studied in detail. The current density applied to produce the low porosity layers was limited in order to keep the electrolyte flow through the multilayer structure and to avoid deformation of layer interfaces. We found that an electrolyte composed of hydrofluoric acid, ethanol and glycerin in a ratio of 3:7:1 gives a refractive index contrast around 1.3/2.8 at 600 nm. Several multilayer structures with this refractive index contrast were fabricated, such as dielectric Bragg mirrors and microcavities. Reflectance spectra of the structures show the photonic quality of porous silicon multilayers produced under these electrochemical conditions. (copyright 2009 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  8. Statistical method for quality control in presence of measurement errors

    International Nuclear Information System (INIS)

    Lauer-Peccoud, M.R.

    1998-01-01

    In a quality inspection of a set of items where the measurements of values of a quality characteristic of the item are contaminated by random errors, one can take wrong decisions which are damageable to the quality. So of is important to control the risks in such a way that a final quality level is insured. We consider that an item is defective or not if the value G of its quality characteristic is larger or smaller than a given level g. We assume that, due to the lack of precision of the measurement instrument, the measurement M of this characteristic is expressed by ∫ (G) + ξ where f is an increasing function such that the value ∫ (g 0 ) is known and ξ is a random error with mean zero and given variance. First we study the problem of the determination of a critical measure m such that a specified quality target is reached after the classification of a lot of items where each item is accepted or rejected depending on whether its measurement is smaller or greater than m. Then we analyse the problem of testing the global quality of a lot from the measurements for a example of items taken from the lot. For these two kinds of problems and for different quality targets, we propose solutions emphasizing on the case where the function ∫ is linear and the error ξ and the variable G are Gaussian. Simulation results allow to appreciate the efficiency of the different considered control procedures and their robustness with respect to deviations from the assumptions used in the theoretical derivations. (author)

  9. Reduction in pediatric identification band errors: a quality collaborative.

    Science.gov (United States)

    Phillips, Shannon Connor; Saysana, Michele; Worley, Sarah; Hain, Paul D

    2012-06-01

    Accurate and consistent placement of a patient identification (ID) band is used in health care to reduce errors associated with patient misidentification. Multiple safety organizations have devoted time and energy to improving patient ID, but no multicenter improvement collaboratives have shown scalability of previously successful interventions. We hoped to reduce by half the pediatric patient ID band error rate, defined as absent, illegible, or inaccurate ID band, across a quality improvement learning collaborative of hospitals in 1 year. On the basis of a previously successful single-site intervention, we conducted a self-selected 6-site collaborative to reduce ID band errors in heterogeneous pediatric hospital settings. The collaborative had 3 phases: preparatory work and employee survey of current practice and barriers, data collection (ID band failure rate), and intervention driven by data and collaborative learning to accelerate change. The collaborative audited 11377 patients for ID band errors between September 2009 and September 2010. The ID band failure rate decreased from 17% to 4.1% (77% relative reduction). Interventions including education of frontline staff regarding correct ID bands as a safety strategy; a change to softer ID bands, including "luggage tag" type ID bands for some patients; and partnering with families and patients through education were applied at all institutions. Over 13 months, a collaborative of pediatric institutions significantly reduced the ID band failure rate. This quality improvement learning collaborative demonstrates that safety improvements tested in a single institution can be disseminated to improve quality of care across large populations of children.

  10. Crystalline lens and refractive development.

    Science.gov (United States)

    Iribarren, Rafael

    2015-07-01

    Individual refractive errors usually change along lifespan. Most children are hyperopic in early life. This hyperopia is usually lost during growth years, leading to emmetropia in adults, but myopia also develops in children during school years or during early adult life. Those subjects who remain emmetropic are prone to have hyperopic shifts in middle life. And even later, at older ages, myopic shifts are developed with nuclear cataract. The eye grows from 15 mm in premature newborns to approximately 24 mm in early adult years, but, in most cases, refractions are maintained stable in a clustered distribution. This growth in axial length would represent a refractive change of more than 40 diopters, which is compensated by changes in corneal and lens powers. The process which maintains the balance between the ocular components of refraction during growth is still under study. As the lens power cannot be measured in vivo, but can only be calculated based on the other ocular components, there have not been many studies of lens power in humans. Yet, recent studies have confirmed that the lens loses power during growth in children, and that hyperopic and myopic shifts in adulthood may be also produced by changes in the lens. These studies in children and adults give a picture of the changing power of the lens along lifespan. Other recent studies about the growth of the lens and the complexity of its internal structure give clues about how these changes in lens power are produced along life. Copyright © 2015 Elsevier Ltd. All rights reserved.

  11. Axial Length/Corneal Radius of Curvature Ratio and Refractive ...

    African Journals Online (AJOL)

    2017-12-05

    Dec 5, 2017 ... variously described as determined by the ocular biometric variables. There have been many studies on the relationship between refractive error and ocular axial length (AL), anterior chamber depth, corneal radius of curvature (CR), keratometric readings as well as other ocular biometric variables such as ...

  12. Scattering properties of ultrafast laser-induced refractive index shaping lenticular structures in hydrogels

    Science.gov (United States)

    Wozniak, Kaitlin T.; Germer, Thomas A.; Butler, Sam C.; Brooks, Daniel R.; Huxlin, Krystel R.; Ellis, Jonathan D.

    2018-02-01

    We present measurements of light scatter induced by a new ultrafast laser technique being developed for laser refractive correction in transparent ophthalmic materials such as cornea, contact lenses, and/or intraocular lenses. In this new technique, called intra-tissue refractive index shaping (IRIS), a 405 nm femtosecond laser is focused and scanned below the corneal surface, inducing a spatially-varying refractive index change that corrects vision errors. In contrast with traditional laser correction techniques, such as laser in-situ keratomileusis (LASIK) or photorefractive keratectomy (PRK), IRIS does not operate via photoablation, but rather changes the refractive index of transparent materials such as cornea and hydrogels. A concern with any laser eye correction technique is additional scatter induced by the process, which can adversely affect vision, especially at night. The goal of this investigation is to identify sources of scatter induced by IRIS and to mitigate possible effects on visual performance in ophthalmic applications. Preliminary light scattering measurements on patterns written into hydrogel showed four sources of scatter, differentiated by distinct behaviors: (1) scattering from scanned lines; (2) scattering from stitching errors, resulting from adjacent scanning fields not being aligned to one another; (3) diffraction from Fresnel zone discontinuities; and (4) long-period variations in the scans that created distinct diffraction peaks, likely due to inconsistent line spacing in the writing instrument. By knowing the nature of these different scattering errors, it will now be possible to modify and optimize the design of IRIS structures to mitigate potential deficits in visual performance in human clinical trials.

  13. Modification of Low Refractive Index Polycarbonate for High Refractive Index Applications

    Directory of Open Access Journals (Sweden)

    Gunjan Suri

    2009-01-01

    Full Text Available Polycarbonates and polythiourethanes are the most popular materials in use today, for optical applications. Polycarbonates are of two types which fall in the category of low refractive index and medium refractive index. The present paper describes the conversion of low refractive index polycarbonates into high refractive index material by the use of a high refractive index monomer, polythiol, as an additive. Novel polycarbonates, where the properties of refractive index and Abbe number can be tailor made, have been obtained. Thermal studies and refractive index determination indicate the formation of a new polymer with improved properties and suitable for optical applications.

  14. Inversion, error analysis, and validation of GPS/MET occultation data

    Directory of Open Access Journals (Sweden)

    A. K. Steiner

    Full Text Available The global positioning system meteorology (GPS/MET experiment was the first practical demonstration of global navigation satellite system (GNSS-based active limb sounding employing the radio occultation technique. This method measures, as principal observable and with millimetric accuracy, the excess phase path (relative to propagation in vacuum of GNSS-transmitted radio waves caused by refraction during passage through the Earth's neutral atmosphere and ionosphere in limb geometry. It shows great potential utility for weather and climate system studies in providing an unique combination of global coverage, high vertical resolution and accuracy, long-term stability, and all-weather capability. We first describe our GPS/MET data processing scheme from excess phases via bending angles to the neutral atmospheric parameters refractivity, density, pressure and temperature. Special emphasis is given to ionospheric correction methodology and the inversion of bending angles to refractivities, where we introduce a matrix inversion technique (instead of the usual integral inversion. The matrix technique is shown to lead to identical results as integral inversion but is more directly extendable to inversion by optimal estimation. The quality of GPS/MET-derived profiles is analyzed with an error estimation analysis employing a Monte Carlo technique. We consider statistical errors together with systematic errors due to upper-boundary initialization of the retrieval by a priori bending angles. Perfect initialization and properly smoothed statistical errors allow for better than 1 K temperature retrieval accuracy up to the stratopause. No initialization and statistical errors yield better than 1 K accuracy up to 30 km but less than 3 K accuracy above 40 km. Given imperfect initialization, biases >2 K propagate down to below 30 km height in unfavorable realistic cases. Furthermore, results of a statistical validation of GPS/MET profiles through comparison

  15. [Correction of light refraction and reflection in medical transmission optical tomography].

    Science.gov (United States)

    Tereshchenko, S A; Potapov, D A

    2002-01-01

    The effects of light refraction and reflection on the quality of image reconstruction in medical transmission optical tomography of high-scattering media are considered. It has been first noted that light refraction not only distorts the geometric scheme of measurements, but may lead to the appearance of object areas that cannot be scanned. Some ways of decreasing the effect of refraction on the reconstruction of spatial distribution of the extinction coefficient are stated.

  16. Accommodation, refractive error and eye growth in chickens.

    Science.gov (United States)

    Schaeffel, F; Glasser, A; Howland, H C

    1988-01-01

    We raised chickens with defocusing lenses of differing powers in front of their eyes. For this purpose, small hoods made from soft, thin leather were carefully fitted to their heads. Lenses were attached to the hoods by velcro fasteners and could be easily removed for cleaning. The powers of the lenses were such that their optical effects could be compensated for by accommodation. It was verified by infrared (IR) photoretinoscopy that the chickens could keep their retinal images in focus. Wearing a lens resulted in a consistent shift of the non cycloplegic refractive state (measured without the lens) which was in the direction to compensate for the lens. We used a sensitive technique (precision = +/- 50 micron as estimated from the variability of repeated measurements) to measure the posterior nodal distance (PND) in excised eyes of birds grown with lenses. The PND, in turn, was used to compare eyes treated with different lenses. It was found that the PND was increased in eyes which were treated with negative lenses compared to those treated with positive lenses. This effect occurs independently in both eyes and it is not due to changes in corneal curvature. We discuss our result in terms of a closed-loop feedback system for the regulation of eye growth.

  17. Do Peripheral Refraction and Aberration Profiles Vary with the Type of Myopia? - An Illustration Using a Ray-Tracing Approach

    Directory of Open Access Journals (Sweden)

    Ravi C. Bakaraju

    2009-01-01

    Conclusion: This study has indicated that myopic eyes with primarily an axial component may have a greater risk of progression than their refractive counterparts albeit with the same degree of refractive error. This prediction emerges from the presented theoretical ray tracing model and, therefore, requires clinical confirmation.

  18. Refractive and ocular biometric profile of children with a history of laser treatment for retinopathy of prematurity.

    Science.gov (United States)

    Kaur, Savleen; Sukhija, Jaspreet; Katoch, Deeksha; Sharma, Mansi; Samanta, Ramanuj; Dogra, Mangat R

    2017-09-01

    Indian children belong to a diverse socioeconomic strata with retinopathy of prematurity (ROP) developing in mature, higher birth weight babies as well. The purpose of our study is to analyze the long-term status of refractive errors and its relationship with ocular biometry in children with ROP who were laser treated at a tertiary center in North India. Cross sectional study. Children (large refractive error predicts the future development of myopia in these children. Nearly 6% of patients with good structural outcome have unexplained subnormal vision. Our threshold for prescribing glasses in these children should be low.

  19. Suppression of Air Refractive Index Variations in High-Resolution Interferometry

    Directory of Open Access Journals (Sweden)

    Zdeněk Buchta

    2011-08-01

    Full Text Available The influence of the refractive index of air has proven to be a major problem on the road to improvement of the uncertainty in interferometric displacement measurements. We propose an approach with two counter-measuring interferometers acting as a combination of tracking refractometer and a displacement interferometer referencing the wavelength of the laser source to a mechanical standard made of a material with ultra-low thermal expansion. This technique combines length measurement within a specified range with measurement of the refractive index fluctuations in one axis. Errors caused by different position of the interferometer laser beam and air sensors are thus eliminated. The method has been experimentally tested in comparison with the indirect measurement of the refractive index of air in a thermal controlled environment. Over a 1 K temperature range an agreement on the level of 5 × 10−8 has been achieved.

  20. Main visual symptoms associated to refractive errors and spectacle need in a Brazilian population

    Directory of Open Access Journals (Sweden)

    Silvana Schellini

    2016-12-01

    Full Text Available AIM: To determine the main visual symptoms in a Brazilian population sample, associated to refractive errors (REs and spectacle need to suggest priorities in preventive programs. METHODS: A cross-sectional study was conducted in nine counties of the southeast region of Brazil, using a systematic sampling of households, between March 2004 and July 2005. The population was defined as individuals aged between 1 and 96y, inhabitants of 3600 residences to be evaluated and 3012 households were included, corresponding to 8010 subjects considered for participation in the survey, of whom 7654 underwent ophthalmic examinations. The individuals were evaluated according their demographic data, eye complaints and eye examination including the RE and the need to prescribe spectacles according to age. Statistical analysis was performed using SPSS software package and descriptive analysis using 95% confidence intervals (P<0.05. RESULTS: The main symptom detected was asthenopia, most frequent in the 2nd and 3rd decades of life, with a significant decline after the 4th decade. Astigmatism was the RE most associated with asthenopia. Reduced near vision sight was more frequent in those ≥40y with a progressive decline thereafter. Spectacles were most frequently required in subjects of ≥40 years of age. CONCLUSION: The main symptom related to the vision was asthenopia and was associated to astigmatism. The greatest need for spectacles prescription occurred after 40’s, mainly to correct near vision. Subjects of ≥40 years old were determined to be at high risk of uncorrected REs. These observations can guide intervention programs for the Brazilian population.

  1. Erros de refração como causas de baixa visual em crianças da rede de escolas públicas da regional de Botucatu - SP Refractive errors as causes of visual impairment in children from public schools of the Botucatu region - SP

    Directory of Open Access Journals (Sweden)

    Claudia Akemi Shiratori de Oliveira

    2009-04-01

    Full Text Available OBJETIVO: Estudar a ocorrência dos erros refracionais em escolares de nosso meio. MÉTODOS: Estudo transversal avaliando crianças da pré-escola e do ensino básico, quanto ao sexo, tipo de erro refracional, acuidade visual e tratamento realizado. RESULTADOS: Quatro mil seiscentos e vinte e três crianças foram submetidas a exame de acuidade visual, das quais 8,1% apresentaram necessidade de exame oftalmológico completo. Houve 63,2% de portadores de astigmatismo hipermetrópico, 15,7% de astigmatismo miópico, 12,5% de astigmatismo misto, 4,9% de hipermetropia e 3,7% de miopia. Foi indicada a prescrição de lentes corretoras para 48,7% da amostra estudada. A frequência de erros refracionais na população foi de 3,9%. CONCLUSÃO: O astigmatismo hipermetrópico foi o erro de refracional mais frequente, havendo necessidade de tratamento em cerca de 50% das crianças triadas com frequência de 3,9% de erro refracional passível de correção na população de estudo.PURPOSE: To evaluate the refractive errors as cause of visual impairment in school children from the Botucatu region. METHODS: A sectional study was conducted evaluating preschool and elementary school students, according to gender, refractive error, visual acuity and treatment. RESULTS: Four thousand six hundred and twenty-three (4,623 children were submitted to visual acuity evaluation and 8.1% of them were submitted to complete ocular examination. There were 63.2% hyperopic astigmatism, 15.7% myopic astigmatism, 12.5% astigmatism, 4.9% hyperopia and 3.7% myopia. Corrective lenses were prescribed for 48.7% of the evaluated children. CONCLUSION: The most frequent refractive error was hyperopic astigmatism and 50% of the children received treatment. The frequency of refractive errors was 3.9% of the studied population.

  2. Source position error influence on industry CT image quality

    International Nuclear Information System (INIS)

    Cong Peng; Li Zhipeng; Wu Haifeng

    2004-01-01

    Based on the emulational exercise, the influence of source position error on industry CT (ICT) image quality was studied and the valuable parameters were obtained for the design of ICT. The vivid container CT image was also acquired from the CT testing system. (authors)

  3. Trial frame refraction versus autorefraction among new patients in a low-vision clinic.

    Science.gov (United States)

    DeCarlo, Dawn K; McGwin, Gerald; Searcey, Karen; Gao, Liyan; Snow, Marsha; Waterbor, John; Owsley, Cynthia

    2013-01-02

    To determine the relationship between refractive error as measured by autorefraction and that measured by trial frame refraction among a sample of adults with vision impairment seen in a university-based low-vision clinic and to determine if autorefraction might be a suitable replacement for trial frame refraction. A retrospective chart review of all new patients 19 years or older seen over an 18-month period was conducted and the following data collected: age, sex, primary ocular diagnosis, entering distance visual acuity, habitual correction, trial frame refraction, autorefraction, and distance visual acuity measured after trial frame refraction. Trial frame refraction and autorefraction were compared using paired t-tests, intraclass correlations, and Bland-Altman plots. Final analyses included 440 patients for whom both trial frame refraction and autorefraction data were available for the better eye. Participants were mostly female (59%) with a mean age of 68 years (SD = 20). Age-related macular degeneration was the most common etiology for vision impairment (44%). Values for autorefraction and trial frame refraction were statistically different, but highly correlated for the spherical equivalent power (r = 0.92), the cylinder power (r = 0.80) and overall blurring strength (0.89). Although the values of the cross-cylinders J(0) and J(45) were similar, they were poorly correlated (0.08 and 0.15, respectively). The range of differences in spherical equivalent power was large (-8.6 to 4.9). Autorefraction is highly correlated with trial frame refraction. Differences are sometimes substantial, making autorefraction an unsuitable substitute for trial frame refraction.

  4. Performance of Photoscreener in Detection of Refractive Error in All Age Groups and Amblyopia Risk Factors in Children in a Tribal District of Odisha: The Tribal Odisha Eye Disease Study (TOES) # 3

    Science.gov (United States)

    Panda, Lapam; Barik, Umasankar; Nayak, Suryasmita; Barik, Biswajit; Behera, Gyanaranjan; Kekunnaya, Ramesh

    2018-01-01

    Purpose To evaluate effectiveness of Welch Allyn Spot Vision Screener in detecting refractive error in all age groups and amblyopia risk factors in children in a tribal district of India. Methods All participants received dry retinoscopy and photorefraction; children also received cycloplegic retinoscopy. Statistical analysis included Bland-Altman and coefficient of determination (R2). Results Photoscreener could not elicit a response in 113 adults and 5 children of 580 recruited participants. In Bland-Altman analysis mean difference of Spot screener spherical equivalent (SSSE) and dry retinoscopy spherical equivalent (DRSE) was 0.32 diopters (D) in adults and 0.18 D in children; this was an overestimation of hyperopia and underestimation of myopia. In Bland-Altman analysis of SSSE and cycloplegic retinoscopy spherical equivalent (CRSE) the mean difference was −0.30 D in children; this was an overestimation of myopia and underestimation of hyperopia. In regression analysis the relationship between SSSE and DRSE was poor in adults (R2 = 0.50) and good in children (R2 = 0.92). Cubic regression model for Spot versus cycloretinoscopy in children was: CRSE = 0.34 + 0.85 SSSE − 0.01 SSSE2 + 0.006 SSSE3. It was 87% accurate. Sensitivity and specificity of Spot in detecting amblyopia risk factors (2013 American Association for Pediatric Ophthalmology and Strabismus [AAPOS] criteria) was 93.3% and 96.9% respectively. Sensitivity of Spot screener in detection of amblyopia was 72%. Conclusions Photoscreener has 87% accuracy in refraction in children. Its value could be used for subjective correction tests. Translational Relevance Photoscreening could complement traditional retinoscopy to address refractive error in children in a resource-limited facility region. PMID:29881649

  5. Prevalence and association of refractive anisometropia with near work habits among young schoolchildren: The evidence from a population-based study.

    Directory of Open Access Journals (Sweden)

    Chia-Wei Lee

    Full Text Available Lifestyle behaviour may play a role in refractive error among children, but the association between near work habits and refractive anisometropia remains unclear.We estimated the prevalence of refractive anisometropia and examined its association with near work activities among 23,114 children in the Myopia Investigation Study in Taipei who were grade 2 elementary school students at baseline in 2013 and 2014. Baseline data on demographics, medical history, parental history and near work habits were collected by parent-administered questionnaire survey. Refractive status was determined by cycloplegic autorefraction. Refractive anisometropia was defined as the spherical equivalent difference ≥ 1.0 diopter between eyes.The prevalence of refractive anisometropia was 5.3% (95% confidence interval [CI], 5.0% to 5.6%. The prevalence and severity of refractive anisometropia increased with both myopic and hyperopic refractive error. Multivariate logistic regression analysis revealed that refractive anisometropia was significantly associated with myopia (odds ratio [OR], 2.98; 95% CI, 2.53-3.51, hyperopia (OR, 2.37; 95% CI, 1.98-2.83, degree of astigmatism (OR, 1.005; 95% CI, 1.005-1.006, amblyopia (OR, 2.54; 95% CI, 2.06-3.12, male gender (OR, 0.88; 95% CI, 0.78-0.99 and senior high school level of maternal education (OR, 0.69; 95% CI, 0.52-0.92. Though anisometropic children were more likely to spend more time on near work (crude OR, 1.15; 95% CI, 1.02-1.29 and to have less eye-to-object distance in doing near work (crude OR, 1.15; 95% CI, 1.01-1.30, these associations became insignificant after additional adjustment for ocular, demographic and parental factors.The present study provides large-scale, population-based evidence showing no independent association between refractive anisometropia and near work habits, though myopia is associated with refractive anisometropia.

  6. Refractive outcomes of intraoperative wavefront aberrometry versus optical biometry alone for intraocular lens power calculation

    Directory of Open Access Journals (Sweden)

    Zina Zhang

    2017-01-01

    Full Text Available Purpose: To compare the outcomes of intraoperative wavefront aberrometry versus optical biometry alone for intraocular lens (IOL power calculation in eyes undergoing cataract surgery with monofocal IOL implantation. Methods: Preoperative data were obtained with the IOLMaster. Intraoperative aphakic measurements and IOL power calculations were obtained in some patients with the optiwave refractive analysis (ORA system. Analysis was performed to determine the accuracy of monofocal IOL power prediction and postoperative manifest refraction at 1 month of the ORA versus IOLMaster. Results: Two hundred and ninety-five eyes reviewed, 61 had only preoperative IOLMaster measurements and 234 had both IOLMaster and ORA measurements. Of these 234 eyes, 6 were excluded, 107 had the same recommended IOL power by ORA and IOLMaster. Sixty-four percent of these eyes were within ±0.5D. 95 eyes had IOL power implantation based on ORA instead of IOLMaster. Seventy percent of these eyes were within ±0.5D of target refraction. 26 eyes had IOL power chosen based on IOLMaster predictions instead of ORA. Sixty-five percent were within ±0.5D. In the group with IOLMaster without ORA measurements, 80% of eyes were within ±0.5D of target refraction. The absolute error was statistically smaller in those eyes where the ORA and IOLMaster recommended the same IOL power based on preoperative target refraction compared to instances in which IOL selection was based on ORA or IOLMaster alone. Neither prediction errors were statistically different between the ORA and IOLMaster alone. Conclusion: Intraoperative wavefront aberrometry with the ORA system provides postoperative refractive results comparable to conventional biometry with the IOLMaster for monofocal IOL selection.

  7. Refractive neutron lens

    International Nuclear Information System (INIS)

    Petrov, P.V.; Kolchevsky, N.N.

    2013-01-01

    Model of the refractive neutron lens is proposed. System of N lenses acts as one thin lens with a complex refraction index n*. The maximum number N max of individual lenses for 'thick' neutron lens is calculated. Refractive neutron lens properties (resolution, focal depth) as function of resolution factor F 0 =ρbc/μ and depth of field factor dF 0 =λF 0 =λρbc/μ are calculated. It is shown that micro resolution of the refractive neutron optics is far from the wavelength in size and its open possibilities for progress in refractive neutron optics. (authors)

  8. Comparison the post operative refractive errors in same size corneal transplantation through deep lamellar keratoplasty and penetrating keratoplasty methods after sutures removing in keratoconus patients

    Directory of Open Access Journals (Sweden)

    Hasan Razmjoo

    2016-01-01

    Full Text Available Background: Corneal transplantation is a surgery in which cornea is replaced by a donated one and can be completely penetrating keratoplasty (PK or included a part of cornea deep lamellar keratoplasty (DLK. Although the functional results are limited by some complications, it is considered as one of the most successful surgeries. This study aimed to compare the refractive errors after same size corneal transplantation through DLK and PK methods in keratoconus patients over 20 years. Materials and Methods: This descriptive, analytical study was conducted in Feiz Hospital, Sadra and Persian Clinics of Isfahan in 2013–2014. In this study, 35 patients underwent corneal transplantation by PK and 35 patients by DLK, after removing the sutures, the patients were compared in terms of best corrected visual acuity (BCVA and refractive errors. Data were analyzed using Chi-square and t Student tests by SPSS software. Results: The BCVA mean in DLK and PK groups was 6/10 ± 2/10 and 5/10 ± 2/10, respectively, with no significant difference (P = 0.4. The results showed 9 cases of DLK and 6 cases of PK had normal (8/10 ≤ BCVA visual acuity (25.7% vs. 17.1%, 24 cases of DLK and 27 cases of PK had mild vision impairment (68.6% vs. 77.1% and 2 cases of the DLK group and 2 cases of PK had moderate vision impairment, (5.7% vs. 5.7%, there was no significant difference in “BCVA” (P = 0.83. Conclusions: Both methods were acceptably effective in improving BCVA, but according to previous articles (5,9,10 the DLK method due to fewer complications and less risk of rejection was superior to another method and in the absence of any prohibition this method is recommended.

  9. Error in the delivery of radiation therapy: Results of a quality assurance review

    International Nuclear Information System (INIS)

    Huang, Grace; Medlam, Gaylene; Lee, Justin; Billingsley, Susan; Bissonnette, Jean-Pierre; Ringash, Jolie; Kane, Gabrielle; Hodgson, David C.

    2005-01-01

    Purpose: To examine error rates in the delivery of radiation therapy (RT), technical factors associated with RT errors, and the influence of a quality improvement intervention on the RT error rate. Methods and materials: We undertook a review of all RT errors that occurred at the Princess Margaret Hospital (Toronto) from January 1, 1997, to December 31, 2002. Errors were identified according to incident report forms that were completed at the time the error occurred. Error rates were calculated per patient, per treated volume (≥1 volume per patient), and per fraction delivered. The association between tumor site and error was analyzed. Logistic regression was used to examine the association between technical factors and the risk of error. Results: Over the study interval, there were 555 errors among 28,136 patient treatments delivered (error rate per patient = 1.97%, 95% confidence interval [CI], 1.81-2.14%) and among 43,302 treated volumes (error rate per volume = 1.28%, 95% CI, 1.18-1.39%). The proportion of fractions with errors from July 1, 2000, to December 31, 2002, was 0.29% (95% CI, 0.27-0.32%). Patients with sarcoma or head-and-neck tumors experienced error rates significantly higher than average (5.54% and 4.58%, respectively); however, when the number of treated volumes was taken into account, the head-and-neck error rate was no longer higher than average (1.43%). The use of accessories was associated with an increased risk of error, and internal wedges were more likely to be associated with an error than external wedges (relative risk = 2.04; 95% CI, 1.11-3.77%). Eighty-seven errors (15.6%) were directly attributed to incorrect programming of the 'record and verify' system. Changes to planning and treatment processes aimed at reducing errors within the head-and-neck site group produced a substantial reduction in the error rate. Conclusions: Errors in the delivery of RT are uncommon and usually of little clinical significance. Patient subgroups and

  10. Ametropia, retinal anatomy, and OCT abnormality patterns in glaucoma. 1. Impacts of refractive error and interartery angle

    Science.gov (United States)

    Elze, Tobias; Baniasadi, Neda; Jin, Qingying; Wang, Hui; Wang, Mengyu

    2017-12-01

    Retinal nerve fiber layer thickness (RNFLT) measured by optical coherence tomography (OCT) is widely used in clinical practice to support glaucoma diagnosis. Clinicians frequently interpret peripapillary RNFLT areas marked as abnormal by OCT machines. However, presently, clinical OCT machines do not take individual retinal anatomy variation into account, and according diagnostic biases have been shown particularly for patients with ametropia. The angle between the two major temporal retinal arteries (interartery angle, IAA) is considered a fundamental retinal ametropia marker. Here, we analyze peripapillary spectral domain OCT RNFLT scans of 691 glaucoma patients and apply multivariate logistic regression to quantitatively compare the diagnostic bias of spherical equivalent (SE) of refractive error and IAA and to identify the precise retinal locations of false-positive/negative abnormality marks. Independent of glaucoma severity (visual field mean deviation), IAA/SE variations biased abnormality marks on OCT RNFLT printouts at 36.7%/22.9% of the peripapillary area, respectively. 17.2% of the biases due to SE are not explained by IAA variation, particularly in inferonasal areas. To conclude, the inclusion of SE and IAA in OCT RNFLT norms would help to increase diagnostic accuracy. Our detailed location maps may help clinicians to reduce diagnostic bias while interpreting retinal OCT scans.

  11. Light-distortion analysis as a possible indicator of visual quality after refractive lens exchange with diffractive multifocal intraocular lenses.

    Science.gov (United States)

    Brito, Pedro; Salgado-Borges, José; Neves, Helena; Gonzalez-Meijome, José; Monteiro, Manuel

    2015-03-01

    To study the perception of light distortion after refractive lens exchange (RLE) with diffractive multifocal intraocular lenses (IOLs). Clínica Oftalmológica das Antas, Porto, Portugal. Retrospective comparative study. Refractive lens exchange was performed with implantation of an AT Lisa 839M (trifocal) or 909MP (bifocal toric) IOL, the latter if corneal astigmatism was more than 0.75 diopter (D). The postoperative visual and refractive outcomes were evaluated. A prototype light-distortion analyzer was used to quantify the postoperative light-distortion indices. A control group of eyes in which a Tecnis ZCB00 1-piece monofocal IOL was implanted had the same examinations. A trifocal or bifocal toric IOL was implanted in 66 eyes. The control IOL was implanted in 18 eyes. All 3 groups obtained a significant improvement in uncorrected distance visual acuity (UDVA) (P refractive cylinder was less than 1.00 D in 86.7% of cases with the toric IOL. The mean light-distortion index was significantly higher in the multifocal IOL groups than in the monofocal group (P light-distortion index and CDVA. The multifocal IOLs provided excellent UDVA and functional UNVA despite increased light-distortion indices. The light-distortion analyzer reliably quantified a subjective component of vision distinct from visual acuity; it may become a useful adjunct in the evaluation of visual quality obtained with multifocal IOLs. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  12. CORRELATION OF FUNDUS CHANGES IN RELATION TO REFRACTIVE ERROR IN PATIENTS WITH MYOPIA- A CLINICAL PROSPECTIVE STUDY

    Directory of Open Access Journals (Sweden)

    Balasubramanian M. Manickavelu

    2018-01-01

    Full Text Available BACKGROUND Retina is unique among the complex element of the central nervous system and the special senses. It may be readily viewed during life and it is sufficiently transparent, so that alterations within and adjacent to it may be observed in vivo. The peripheral retina owing to its thinness comparing to that of the central part, poorly-developed retinal cells, absence of large blood vessels, relatively insensitive to light, less resistance to traction, forms a seat for various lesions, which are potentially dangerous for the vision. It is in myopia that we meet the most frequent and the most obvious anomalies in the fundus changes, which bear some relation to the degree of myopia and appeal to be concerned with it either as a cause or effect or perhaps both. The aim of our study is to correlate fundus changes in relation to refractive error in patients with myopia. MATERIALS AND METHODS In our study, 100 cases of myopic (-6D:50 cases patients were selected. Detailed evaluation done. History of refractive error includes duration, age at which spectacles were worn for the first time. Time of last change of spectacles, family history of myopia, history of other symptoms like progressive loss of vision, defective vision related to day or night, sudden loss of vision, flashes and floaters. Anterior segment was examined followed by the recording of initial visual acuity and the best corrected visual acuity was noted. IOP was measured for all the cases using Schiotz tonometry. Axial length was measured in all the cases. Fundus examined with direct ophthalmoscope, indirect ophthalmoscope, 3 mirror and 90D lens. Bscan was done in few cases. The media, disc, vessels, macula and the surrounding retina were examined. The periphery was examined with indentation method. The various fundus features and pathological lesions in different degrees of myopia were noted. RESULTS Females were comparatively more affected. Highest incidence was seen in the younger

  13. An investigation of Saudi Arabian MR radiographers' knowledge and confidence in relation to MR image-quality-related errors

    International Nuclear Information System (INIS)

    Alsharif, W.; Davis, M.; McGee, A.; Rainford, L.

    2017-01-01

    Objective: To investigate MR radiographers' current knowledge base and confidence level in relation to quality-related errors within MR images. Method: Thirty-five MR radiographers within 16 MRI departments in the Kingdom of Saudi Arabia (KSA) independently reviewed a prepared set of 25 MR images, naming the error, specifying the error-correction strategy, scoring how confident they were in recognising this error and suggesting a correction strategy by using a scale of 1–100. The datasets were obtained from MRI departments in the KSA to represent the range of images which depicted excellent, acceptable and poor image quality. Results: The findings demonstrated a low level of radiographer knowledge in identifying the type of quality errors and when suggesting an appropriate strategy to rectify those errors. The findings show that only (n = 7) 20% of the radiographers could correctly name what the quality errors were in 70% of the dataset, and none of the radiographers correctly specified the error-correction strategy in more than 68% of the MR datasets. The confidence level of radiography participants in their ability to state the type of image quality errors was significantly different (p < 0.001) for who work in different hospital types. Conclusion: The findings of this study suggest there is a need to establish a national association for MR radiographers to monitor training and the development of postgraduate MRI education in Saudi Arabia to improve the current status of the MR radiographers' knowledge and direct high quality service delivery. - Highlights: • MR radiographers recognised the existence of the image quality related errors. • A few MR radiographers were able to correctly identify which image quality errors were being shown. • None of MR radiographers were able to correctly specify error-correction strategy of the image quality errors. • A low level of knowledge was demonstrated in identifying and rectify image quality errors.

  14. Tomographic method for measurement of the gradient refractive index of the crystalline lens. I. The spherical fish lens.

    Science.gov (United States)

    Acosta, Eva; Vazquez, Daniel; Garner, Leon; Smith, George

    2005-03-01

    We present an iterative tomographic algorithm to reconstruct refractive-index profiles for meridional planes of the lens of the spherical fish eye from measurements of deflection angles of refracted rays. Numerical simulations show that the algorithm allows accuracy up to the fourth decimal place, provided that the refractive index can be regarded as an analytical function of the radial coordinate and the experimental errors are neglected. An experimental demonstration is given by applying the algorithm to retrieve the refractive-index profile of a spherical fish lens. The method is conceptually simple and does not require matching of the index of the surrounding medium to that of the surface of the lens, and the related iterative algorithm rapidly converges.

  15. Correlation between Corneal Thickness and Degree of Myopic Refractory Error

    Directory of Open Access Journals (Sweden)

    A Mortazavi

    2005-01-01

    Full Text Available Background: corneal thickness is an important factor in refractive surgeries such as Radial Keratotomy (RK, Photo Refractive Keratotomy (PRK and Laser Insitu Keratomileusis (LASIK. This study evaluated the correlation between this factor and the degree of myopic refractory error. Methods: In this cross-sectional study, 224 myopic eyes (112 patients which had undergone LASIK operation were assessed. These patients had referred to Aban Eye Clinic, Isfahan, Iran, during August and September 2002. Corneal thickness was measured by ORB SCAN Topoghraphy, and cycloplegic refraction was performed with autorefratometery and retinoscopy. Suspected keratoconus cases and hyperopic patients were excluded. Results: The patients' age was 27.2 ± 1.36 in men (N = 35 and 30.13 ± 1.04 in women (N = 77. Mean value of myopic refractory error in male patients was 5.1 ± 0.24D and in female patients was 3.8 ± 0.36D. Mean of corneal thickness was 540 ± 5.25 µM and 530 ± 5.88 µM in male and female patients respectively. There was no correlation between the degree of myopia and corneal thickness in any of the patients. Also in this research, no relations between the age and myopia were found. Right eye (P > 0.5, r = 0.124 Left eye (P > 0.5, r = 0.104. Conclusion: Based on our findings, corneal thickness and myopic refectory error do not seem to have any relations. (r = 0.039, p = 0.684. Keywords: Corneal Thickness, Cornea, Myopia, LASIK, Refractory Error

  16. Slide-position errors degrade machined optical component quality

    International Nuclear Information System (INIS)

    Arnold, J.B.; Steger, P.J.; Burleson, R.R.

    1975-01-01

    An ultraprecision lathe is being developed at the Oak Ridge Y-12 Plant to fabricate optical components for use in high-energy laser systems. The lathe has the capability to produce virtually any shape mirror which is symmetrical about an axis of revolution. Two basic types of mirrors are fabricated on the lathe, namely: (1) mirrors which are machined using a single slide motion (such as flats and cylinders), and (2) mirrors which are produced by two-coordinated slide motions (such as hyperbolic reflectors; large, true-radius reflectors, and other contoured-surface reflectors). The surface-finish quality of typical mirrors machined by a single axis of motion is better than 13 nm, peak to valley, which is an order of magnitude better than the surface finishes of mirrors produced by two axes of motion. Surface finish refers to short-wavelength-figure errors that are visibly detectable. The primary cause of the inability to produce significantly better surface finishes on contoured mirrors has been determined as positional errors which exist in the slide positioning systems. The correction of these errors must be accomplished before contoured surface finishes comparable to the flat and cylinder can be machined on the lathe

  17. RADIO REFRACTIVITY RADIO REFRACTIVITY STUDY IN AKURE ...

    African Journals Online (AJOL)

    eobe

    Propagation of waves in a microwave link is through the troposphere which is the non-ionized lowest portion of the atmosphere [5]. The refractive index is defined as [5]. (1). Where εr is the dielectric constant of the troposphere. C is the speed of light and V is the phase velocity of the wave in the medium. The refractive index ...

  18. Quality assurance and human error effects on the structural safety

    International Nuclear Information System (INIS)

    Bertero, R.; Lopez, R.; Sarrate, M.

    1991-01-01

    Statistical surveys show that the frequency of failure of structures is much larger than that expected by the codes. Evidence exists that human errors (especially during the design process) is the main cause for the difference between the failure probability admitted by codes and the reality. In this paper, the attenuation of human error effects using tools of quality assurance is analyzed. In particular, the importance of the independent design review is highlighted, and different approaches are discussed. The experience from the Atucha II project, as well as the USA and German practice on independent design review, are summarized. (Author)

  19. Quality assurance of human error modelling in a major probabilistic risk assessment programme

    International Nuclear Information System (INIS)

    Rycraft, H.S.

    1990-01-01

    A method of incorporating the consideration of operator error within a major PRA exercise is described along with the quality assurance procedures employed to ensure a quality product. The exercise was undertaken at the Sellafield Reprocessing Plant. (author)

  20. Parsimonious refraction interferometry

    KAUST Repository

    Hanafy, Sherif

    2016-09-06

    We present parsimonious refraction interferometry where a densely populated refraction data set can be obtained from just two shot gathers. The assumptions are that the first arrivals are comprised of head waves and direct waves, and a pair of reciprocal shot gathers is recorded over the line of interest. The refraction traveltimes from these reciprocal shot gathers can be picked and decomposed into O(N2) refraction traveltimes generated by N virtual sources, where N is the number of geophones in the 2D survey. This enormous increase in the number of virtual traveltime picks and associated rays, compared to the 2N traveltimes from the two reciprocal shot gathers, allows for increased model resolution and better condition numbers in the normal equations. Also, a reciprocal survey is far less time consuming than a standard refraction survey with a dense distribution of sources.

  1. Parsimonious refraction interferometry

    KAUST Repository

    Hanafy, Sherif; Schuster, Gerard T.

    2016-01-01

    We present parsimonious refraction interferometry where a densely populated refraction data set can be obtained from just two shot gathers. The assumptions are that the first arrivals are comprised of head waves and direct waves, and a pair of reciprocal shot gathers is recorded over the line of interest. The refraction traveltimes from these reciprocal shot gathers can be picked and decomposed into O(N2) refraction traveltimes generated by N virtual sources, where N is the number of geophones in the 2D survey. This enormous increase in the number of virtual traveltime picks and associated rays, compared to the 2N traveltimes from the two reciprocal shot gathers, allows for increased model resolution and better condition numbers in the normal equations. Also, a reciprocal survey is far less time consuming than a standard refraction survey with a dense distribution of sources.

  2. Interactive Dynamic Volume Illumination with Refraction and Caustics.

    Science.gov (United States)

    Magnus, Jens G; Bruckner, Stefan

    2018-01-01

    In recent years, significant progress has been made in developing high-quality interactive methods for realistic volume illumination. However, refraction - despite being an important aspect of light propagation in participating media - has so far only received little attention. In this paper, we present a novel approach for refractive volume illumination including caustics capable of interactive frame rates. By interleaving light and viewing ray propagation, our technique avoids memory-intensive storage of illumination information and does not require any precomputation. It is fully dynamic and all parameters such as light position and transfer function can be modified interactively without a performance penalty.

  3. Refraction and the axial length of the eyeball in patients with the optic disc drusen.

    Science.gov (United States)

    Obuchowska, Iwona; Mariak, Zofia

    2009-01-01

    The aim of the study was to demonstrate the relationship between the optic disc drusen (ODD) and the axial length of the eyeball as well as refractive error. We examined prospectively 40 patients with ODD, 18 men and 22 women, age range from 34 to 69 years. All subjects underwent full ophthalmic examination, visual field testing and color-coded duplex sonography of the ocular vessels. Refraction was determined with an autorefractometer (Topcon RM-8000B) and further refined subjectively. Spherical equivalent refraction was calculated as the spherical dioptre plus one half of the cylindrical dioptre. Axial lengths were measured with a Sonomed ultrasound scanner model E-Z Scan AB5500. Clinical signs were observed in 65% of the eyes with drusen, among them, 38% had symptoms of visual acuity loss and all had visual fields defects. There were 21 eyes (18 eyes with and 3 without drusen), with a recorded refractive error. Significant differences in hyperopia were observed between the eyes with and without drusen (p = 0.048). The rate of occurrence of myopia did not differ significantly between affected and unaffected eyes (p = 0.06). The mean spherical equivalent refraction and axial dimensions of the eye differed significantly among the groups of eyes with and without drusen (p < 0.05). Significant differences in mean values of peak-systolic and end-diastolic velocities (p < 0.001) as well as in the resistivity index (p = 0.047) were observed between eyes with and without drusen. The optic disc drusen are often associated with shorter and hyperopic eyes. This anatomical conditions and vascular factors may contribute to pathogenesis of drusen.

  4. Calculation and simulation of atmospheric refraction effects in maritime environments

    Science.gov (United States)

    Dion, Denis, Jr.; Gardenal, Lionel; Lahaie, P.; Forand, J. Luc

    2001-01-01

    Near the sea surface, atmospheric refraction and turbulence affect both IR transmission and image quality. This produces an impact on both the detection and classification/identification of targets. With the financial participation of the U.S. Office of Naval Research (ONR), Canada's Defence Research Establishment Valcartier (DREV) is developing PRIME (Propagation Resources In the Maritime Environment), a computer model aimed at describing the overall atmospheric effects on IR imagery systems in the marine surface layer. PRIME can be used as a complement to MODTRAN to compute the effective transmittance in the marine surface layer, taking into account the lens effects caused by refraction. It also provides information on image degradation caused by both refraction and turbulence. This paper reviews the refraction phenomena that take place in the surface layer and discusses their effects on target detection and identification. We then show how PRIME can benefit detection studies and image degradation simulations.

  5. Intraocular lens calculation adjustment after laser refractive surgery using Scheimpflug imaging.

    Science.gov (United States)

    Schuster, Alexander K; Schanzlin, David J; Thomas, Karin E; Heichel, Christopher W; Purcell, Tracy L; Barker, Patrick D

    2016-02-01

    To test a new method of intraocular lens (IOL) calculation after corneal refractive surgery using Scheimpflug imaging (Pentacam HR) and partial coherence interferometry (PCI) (IOLMaster) that does not require historical data; that is, the Schuster/Schanzlin-Thomas-Purcell (SToP) IOL calculator. Shiley Eye Center, San Diego, California, and Walter Reed National Military Medical Center, Bethesda, Maryland, USA. Retrospective data analysis and validation study. Data were retrospectively collected from patient charts including data from Scheimpflug imaging and refractive history. Target refraction was calculated using PCI and the Holladay 1 and SRK/T formulas. Regression analysis was performed to explain the deviation of the target refraction, taking into account the following influencing factors: ratio of posterior-to-anterior corneal radius, axial length (AL), and anterior corneal radius. The regression analysis study included 61 eyes (39 patients) that had laser in situ keratomileusis (57 eyes) or photorefractive keratectomy (4 eyes) and subsequent cataract. Two factors were found that explained the deviation of the target refraction using the Holladay 1 formula; that is, the ratio of the corneal radii and the AL and the ratio of corneal radii for the SRK/T formula. A new IOL adjustment calculator was derived and validated at a second center using 14 eyes (10 patients). The error in IOL calculation for normal eyes after laser refractive treatment was related to the ratio of posterior-to-anterior corneal radius. A formula requiring Scheimpflug data and suggested IOL power only yielded an improved postoperative result for patients with previous corneal laser refractive surgery having cataract surgery. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2016 ASCRS and ESCRS. All rights reserved.

  6. Influence of Refraction on the Applicability of the Zehnder-Mach Interferometer to Studies of Cooled Boundary Layers

    National Research Council Canada - National Science Library

    Kinsler, Martin

    1951-01-01

    .... It was found that for low wall to free-stream temperature ratios, the effects of light refraction may cause considerable error in the boundary-layer density profiles calculated from interferogram...

  7. Refractive outcome of premature infants with or without retinopathy of prematurity at 2 years of age: A prospective controlled cohort study

    Directory of Open Access Journals (Sweden)

    Ching-ju Hsieh

    2012-04-01

    Full Text Available This study evaluated the extent to which refractive morbidity is correlated to preterm birth or retinopathy of prematurity (ROP itself, or both, and examined the risk factors associated with refractive errors in a cohort of preterm infants with and without ROP compared with full-term infants. This longitudinal, prospective, controlled cohort study enrolled 109 infants, including 74 preterm and 35 full-term infants. Infants were divided into the following groups: no ROP, regressed ROP, laser-treated threshold ROP, and full-term. Cycloplegic refraction was determined at 6 and 24 months’ corrected age. Multiple regression models, analysis of variance (ANOVA with post hoc comparisons, paired t test, and the χ2 test were used for data analysis. ROP status was highly predictive of significant refractive errors in preterm infants. Eyes with laser-treated threshold ROP had significant myopia at both ages (mean spherical equivalent [MSE] in right eye at both refractions −0.72, −1.21 diopters [D], astigmatism (MSE −1.62, −1.80 D, and anisometropia (MSE 0.82, 1.02 D; ANOVA p  0.05. Thus, the persistent hyperopic status across ages in patients with regressed ROP and in patients without ROP differed significantly (paired t test p > 0.05 from that in the full-term infants, with a reduction in hypermetropia noted for the first 2 years of life (paired t test p < 0.05. The incidence and magnitude of significant refractive errors increased with severe ROP and with age. Although the emmetropization process of preterm birth, including regressed ROP and no ROP, differed from full-term birth in early infancy, we found no differences in the refractive status after 1 year in patients with regressed ROP and in patients without ROP, who were at risk of developing ametropia similar to that of full-term patients. Therefore, apart from laser-treated ROP, children with regressed ROP and without ROP can likely be observed with a verbal vision screening at 3

  8. Refractive and Biometric Outcomes in Patients with Retinopathy of Prematurity Treated with Intravitreal Injection of Ranibizumab as Compared with Bevacizumab: A Clinical Study of Correction at Three Years of Age.

    Science.gov (United States)

    Chen, Yen-Chih; Chen, San-Ni; Yang, Benjamin Chi-Lan; Lee, Kun-Hsien; Chuang, Chih-Chun; Cheng, Chieh-Yin

    2018-01-01

    To compare refractive and biometric outcomes in patients with type 1 retinopathy of prematurity (ROP) treated with intravitreal injection of ranibizumab (IVR) versus bevacizumab (IVB), at a corrected age of 3 years. A retrospective case series compared cycloplegic refractive statuses and biometric statuses in patients who received either IVR or IVB for type 1 ROP, from April 2011 to April 2014. A total of 62 eyes (33 patients) with type 1 ROP were evaluated (26 eyes in 13 IVR patients and 36 eyes in 20 IVB patients). There were no differences in birth statuses including gestational age and birth body weight between the two groups. The prevalence of refractive error greater than 1 D was higher in the IVB group ( p = 0.03), and there was a higher prevalence of high myopia (biometric finding showed that IVB patients had shallower anterior chamber depth ( p = 0.01). Both IVR and IVB showed low refractive errors, even followed at the corrected age of 3 years. No difference was noted between the two groups in refractive statuses. However, IVB was associated with shallower anterior chamber and higher prevalence of refractive error at the corrected age of 3 years. This trial is registered with NCT03334513.

  9. Confining light with negative refraction in checkerboard metamaterials and photonic crystals

    International Nuclear Information System (INIS)

    Ramakrishna, S. Anantha; Guenneau, S.; Enoch, S.; Tayeb, G.; Gralak, B.

    2007-01-01

    We present here a finite slab of triangular checkerboard of negative refractive index material that exhibits a form of extraordinary transmission. We show that such a checkerboard can be used to confine light and can act as an open resonator. Effectively even a single point of intersection between three triangular wedges of negative refractive index may act as a resonator that confines light in the limit when n tends toward -1. We find that the quality of the confinement improves by adding more triangular wedges around the initial point in a checkerboard fashion. The confinement effect is also demonstrated by using a photonic crystal that shows the negative refraction effect

  10. A Predictor of Quality of Life of the Mainstreamed Elementary Students: Cognitive Errors

    Science.gov (United States)

    Odaci, Hatice; Kalkan, Melek; Karasu, Pinar

    2009-01-01

    The aim of this study is to examine the cognitive errors as predictor of quality of life of mainstreamed elementary students. Quality of life is the degree of well-being felt by an individual. The functional deficiencies, which occur due to physical, cognitive, sensory, emotional disorders, affect the quality of life of the individuals. In this…

  11. Prevalence of visual impairment and refractive error in school-aged children in South Darfur State of Sudan

    Directory of Open Access Journals (Sweden)

    Saif H. Alrasheed

    2016-10-01

    Full Text Available Background: Global estimates suggest there are almost 19 million visually impaired children worldwide, the major cause being uncorrected refractive error (RE. Aim: To assess the prevalence of visual impairment (VI and RE among Sudanese school-aged children. Setting: Eight randomly selected primary schools from 21 districts in South Darfur State of Sudan were involved. Methods: A school-based cross-sectional study of RE and VI in primary schoolchildren from grades 1 to 8 (children aged 6–15 years was investigated. A Refractive Error Study in Children (RESC protocol was implemented to determine the prevalence of RE and VI in these schoolaged children. Participants were enrolled through stratified multistage cluster sampling of four all-male and four all-female primary schools from South Darfur State of Sudan. Examination procedures followed the RESC protocol, which included visual acuity (VA measurements, binocular vision assessments, retinoscopy and autorefraction under cycloplegia, as well as examination of the external eye, anterior-segment, media and fundus. Results: A total of 1775 children were invited to participate in the study and 1678 were examined resulting in a participation rate of 94.5%. The findings indicated that the prevalence of uncorrected, presenting and best-corrected VA of 6/12 or worse was 6.4% (95% confidence interval [CI], 4.9–7.9, 4.4% (95% CI, 2.9–5.9 and 1.2% (95% CI, 0.3–2.7 respectively. RE was the cause of VI in 57% of participants, retinal disorders in 13.1%, amblyopia in 5.6%, corneal opacity in 0.9%, cataract in 3.7%, with the causes of reduced vision undetermined in 10.3% and various other causes contributed 9.3%. External and anterior-segment abnormalities were observed in 10.2% of children. This was mainly allergic conjunctivitis (5.3% followed by bacterial and viral conjunctivitis (4.2%. The prevalence of myopia (≥|-0.50 D| in one or both eyes was 6.8% (95% CI, 5.3–8.3, hypermetropia (≥ 2 D was

  12. Errors in clinical laboratories or errors in laboratory medicine?

    Science.gov (United States)

    Plebani, Mario

    2006-01-01

    Laboratory testing is a highly complex process and, although laboratory services are relatively safe, they are not as safe as they could or should be. Clinical laboratories have long focused their attention on quality control methods and quality assessment programs dealing with analytical aspects of testing. However, a growing body of evidence accumulated in recent decades demonstrates that quality in clinical laboratories cannot be assured by merely focusing on purely analytical aspects. The more recent surveys on errors in laboratory medicine conclude that in the delivery of laboratory testing, mistakes occur more frequently before (pre-analytical) and after (post-analytical) the test has been performed. Most errors are due to pre-analytical factors (46-68.2% of total errors), while a high error rate (18.5-47% of total errors) has also been found in the post-analytical phase. Errors due to analytical problems have been significantly reduced over time, but there is evidence that, particularly for immunoassays, interference may have a serious impact on patients. A description of the most frequent and risky pre-, intra- and post-analytical errors and advice on practical steps for measuring and reducing the risk of errors is therefore given in the present paper. Many mistakes in the Total Testing Process are called "laboratory errors", although these may be due to poor communication, action taken by others involved in the testing process (e.g., physicians, nurses and phlebotomists), or poorly designed processes, all of which are beyond the laboratory's control. Likewise, there is evidence that laboratory information is only partially utilized. A recent document from the International Organization for Standardization (ISO) recommends a new, broader definition of the term "laboratory error" and a classification of errors according to different criteria. In a modern approach to total quality, centered on patients' needs and satisfaction, the risk of errors and mistakes

  13. Investigation of the refractive status of preschool children in Xiantao, Hubei Province

    Directory of Open Access Journals (Sweden)

    Nian Guan

    2014-12-01

    Full Text Available AIM: To investigate the refractive status of the preschool children in Xiantao, Hubei Province in order to find out the abnormal refraction error beyond the physiological range. METHODS: In this cross-sectional study, we investigated preschool children in kindergartens and the scattered ones were 12 716(25 432 eyesranging from 6mo~6 years old. 1 581 children(3 162 eyeswere diagnosed ametropia by Suresight refractive screening instrument, which were confirmed again after mydriasis optometry. RESULTS: The incidence rate of ametropia in preschool children in Xiantao was 12.4%, and statistics showed no significant difference between boys and girls(P>0.05, but had differences of morbility rate among each age group(PCONCLUSION: The incidence rate of ametropia decreases with age increasing in the preschool children from 6mo~6 years old, which imply preschool children should have mydriasis optometry in order to find out amblyopia and other congenital eye disease.

  14. Short-term stability in refractive status despite large fluctuations in glucose levels in diabetes mellitus type 1 and 2.

    Directory of Open Access Journals (Sweden)

    Byki Huntjens

    Full Text Available PURPOSE: This work investigates how short-term changes in blood glucose concentration affect the refractive components of the diabetic eye in patients with long-term Type 1 and Type 2 diabetes. METHODS: Blood glucose concentration, refractive error components (mean spherical equivalent MSE, J0, J45, central corneal thickness (CCT, anterior chamber depth (ACD, crystalline lens thickness (LT, axial length (AL and ocular aberrations were monitored at two-hourly intervals over a 12-hour period in: 20 T1DM patients (mean age ± SD 38±14 years, baseline HbA1c 8.6±1.9%; 21 T2DM patients (mean age ± SD 56±11 years, HbA1c 7.5±1.8%; and in 20 control subjects (mean age ± SD 49±23 years, HbA1c 5.5±0.5%. The refractive and biometric results were compared with the corresponding changes in blood glucose concentration. RESULTS: Blood glucose concentration at different times was found to vary significantly within (p0.05. Minor changes of marginal statistical or optical significance were observed in some biometric parameters. Similarly there were some marginally significant differences between the baseline biometric parameters of well-controlled and poorly-controlled diabetic subjects. CONCLUSION: This work suggests that normal, short-term fluctuations (of up to about 6 mM/l on a timescale of a few hours in the blood glucose levels of diabetics are not usually associated with acute changes in refractive error or ocular wavefront aberrations. It is therefore possible that factors other than refractive error fluctuations are sometimes responsible for the transient visual problems often reported by diabetic patients.

  15. Characterization of model errors in the calculation of tangent heights for atmospheric infrared limb measurements

    Directory of Open Access Journals (Sweden)

    M. Ridolfi

    2014-12-01

    Full Text Available We review the main factors driving the calculation of the tangent height of spaceborne limb measurements: the ray-tracing method, the refractive index model and the assumed atmosphere. We find that commonly used ray tracing and refraction models are very accurate, at least in the mid-infrared. The factor with largest effect in the tangent height calculation is the assumed atmosphere. Using a climatological model in place of the real atmosphere may cause tangent height errors up to ± 200 m. Depending on the adopted retrieval scheme, these errors may have a significant impact on the derived profiles.

  16. Identifying Children at Risk of High Myopia Using Population Centile Curves of Refraction.

    Directory of Open Access Journals (Sweden)

    Yanxian Chen

    Full Text Available To construct reference centile curves of refraction based on population-based data as an age-specific severity scale to evaluate their efficacy as a tool for identifying children at risk of developing high myopia in a longitudinal study.Data of 4218 children aged 5-15 years from the Guangzhou Refractive Error Study in Children (RESC study, and 354 first-born twins from the Guangzhou Twin Eye Study (GTES with annual visit were included in the analysis. Reference centile curves for refraction were constructed using a quantile regression model based on the cycloplegic refraction data from the RESC. The risk of developing high myopia (spherical equivalent ≤ -6 diopters [D] was evaluated as a diagnostic test using the twin follow-up data.The centile curves suggested that the 3rd, 5th, and 10th percentile decreased from -0.25 D, 0.00 D and 0.25 D in 5 year-olds to -6.00 D, -5.65D and -4.63 D in 15 year-olds in the population-based data from RESC. In the GTES cohort, the 5th centile showed the most effective diagnostic value with a sensitivity of 92.9%, a specificity of 97.9% and a positive predictive value (PPV of 65.0% in predicting high myopia onset (≤-6.00D before the age of 15 years. The PPV was highest (87.5% in 3rd centile but with only 50.0% sensitivity. The Mathew's correlation coefficient of 5th centile in predicting myopia of -6.0D/-5.0D/-4.0D by age of 15 was 0.77/0.51/0.30 respectively.Reference centile curves provide an age-specific estimation on a severity scale of refractive error in school-aged children. Children located under lower percentiles at young age were more likely to have high myopia at 15 years or probably in adulthood.

  17. Sleep quality, posttraumatic stress, depression, and human errors in train drivers: a population-based nationwide study in South Korea.

    Science.gov (United States)

    Jeon, Hong Jin; Kim, Ji-Hae; Kim, Bin-Na; Park, Seung Jin; Fava, Maurizio; Mischoulon, David; Kang, Eun-Ho; Roh, Sungwon; Lee, Dongsoo

    2014-12-01

    Human error is defined as an unintended error that is attributable to humans rather than machines, and that is important to avoid to prevent accidents. We aimed to investigate the association between sleep quality and human errors among train drivers. Cross-sectional. Population-based. A sample of 5,480 subjects who were actively working as train drivers were recruited in South Korea. The participants were 4,634 drivers who completed all questionnaires (response rate 84.6%). None. The Pittsburgh Sleep Quality Index (PSQI), the Center for Epidemiologic Studies Depression Scale (CES-D), the Impact of Event Scale-Revised (IES-R), the State-Trait Anxiety Inventory (STAI), and the Korean Occupational Stress Scale (KOSS). Of 4,634 train drivers, 349 (7.5%) showed more than one human error per 5 y. Human errors were associated with poor sleep quality, higher PSQI total scores, short sleep duration at night, and longer sleep latency. Among train drivers with poor sleep quality, those who experienced severe posttraumatic stress showed a significantly higher number of human errors than those without. Multiple logistic regression analysis showed that human errors were significantly associated with poor sleep quality and posttraumatic stress, whereas there were no significant associations with depression, trait and state anxiety, and work stress after adjusting for age, sex, education years, marital status, and career duration. Poor sleep quality was found to be associated with more human errors in train drivers, especially in those who experienced severe posttraumatic stress. © 2014 Associated Professional Sleep Societies, LLC.

  18. [ISO 9001-2000 certification for refractive laser treatment].

    Science.gov (United States)

    Lebuisson, D A; Arson, B; Abenhaïm, A; Albou-Ganem, C; Assouline, M; Chong Sit, D; Danan, A; Montefiore, G; Montin, J-F; Nguyen-Khoa, J-L; Pietrini, D; Saragoussi, J-J; Trong, Th; Amar, R

    2005-05-01

    To obtain ISO 9001-2000 certification for laser corneal refractive treatment, never before sought in Europe. The consulting firm Veritas led the certification process with the clinic's staff manager. This ISO norm is dedicated to the implementation of a quality management system. We assessed and optimized all necessary resources, evaluating customer satisfaction using patient and referring-physician surveys. We started quality rounds including surgeons, nurses, and technicians. Based on this preparation, we redefined and explained all processes including staff responsibilities and necessary resources in the quality manual. The procedure lasted 14 months with substantial involvement on the part of the management. Unconditional ISO 9001-2000 certification was granted by the independent audit firm, BVQI, in december 2003 for refractive laser treatment. The 2000 version of the new ISO 9001-2000 seeks to meet the demand for improving health care delivery in this field, most particularly by establishing a clear procedural orientation. Such certification enhances team work, stabilizes methodologies, and reinforces cohesion and self-audit. Patients notice that the center follows a consistent quality policy and are assured that the clinic respects rules and regulations. Certification is an advantageous alternative when accreditation cannot be considered. Our article discusses the steps taken in upper management, quality management, procedural guidance, as well as customer and staff counselling. It also discusses the project's cost/benefit ratio for the organization.

  19. Iterative supervirtual refraction interferometry

    KAUST Repository

    Al-Hagan, Ola

    2014-05-02

    In refraction tomography, the low signal-to-noise ratio (S/N) can be a major obstacle in picking the first-break arrivals at the far-offset receivers. To increase the S/N, we evaluated iterative supervirtual refraction interferometry (ISVI), which is an extension of the supervirtual refraction interferometry method. In this method, supervirtual traces are computed and then iteratively reused to generate supervirtual traces with a higher S/N. Our empirical results with both synthetic and field data revealed that ISVI can significantly boost up the S/N of far-offset traces. The drawback is that using refraction events from more than one refractor can introduce unacceptable artifacts into the final traveltime versus offset curve. This problem can be avoided by careful windowing of refraction events.

  20. Iterative supervirtual refraction interferometry

    KAUST Repository

    Al-Hagan, Ola; Hanafy, Sherif M.; Schuster, Gerard T.

    2014-01-01

    In refraction tomography, the low signal-to-noise ratio (S/N) can be a major obstacle in picking the first-break arrivals at the far-offset receivers. To increase the S/N, we evaluated iterative supervirtual refraction interferometry (ISVI), which is an extension of the supervirtual refraction interferometry method. In this method, supervirtual traces are computed and then iteratively reused to generate supervirtual traces with a higher S/N. Our empirical results with both synthetic and field data revealed that ISVI can significantly boost up the S/N of far-offset traces. The drawback is that using refraction events from more than one refractor can introduce unacceptable artifacts into the final traveltime versus offset curve. This problem can be avoided by careful windowing of refraction events.

  1. Understanding refraction contrast using a comparison of absorption and refraction computed tomographic techniques

    Science.gov (United States)

    Wiebe, S.; Rhoades, G.; Wei, Z.; Rosenberg, A.; Belev, G.; Chapman, D.

    2013-05-01

    Refraction x-ray contrast is an imaging modality used primarily in a research setting at synchrotron facilities, which have a biomedical imaging research program. The most common method for exploiting refraction contrast is by using a technique called Diffraction Enhanced Imaging (DEI). The DEI apparatus allows the detection of refraction between two materials and produces a unique ''edge enhanced'' contrast appearance, very different from the traditional absorption x-ray imaging used in clinical radiology. In this paper we aim to explain the features of x-ray refraction contrast as a typical clinical radiologist would understand. Then a discussion regarding what needs to be considered in the interpretation of the refraction image takes place. Finally we present a discussion about the limitations of planar refraction imaging and the potential of DEI Computed Tomography. This is an original work that has not been submitted to any other source for publication. The authors have no commercial interests or conflicts of interest to disclose.

  2. Pediatric Anesthesiology Fellows' Perception of Quality of Attending Supervision and Medical Errors.

    Science.gov (United States)

    Benzon, Hubert A; Hajduk, John; De Oliveira, Gildasio; Suresh, Santhanam; Nizamuddin, Sarah L; McCarthy, Robert; Jagannathan, Narasimhan

    2018-02-01

    Appropriate supervision has been shown to reduce medical errors in anesthesiology residents and other trainees across various specialties. Nonetheless, supervision of pediatric anesthesiology fellows has yet to be evaluated. The main objective of this survey investigation was to evaluate supervision of pediatric anesthesiology fellows in the United States. We hypothesized that there was an indirect association between perceived quality of faculty supervision of pediatric anesthesiology fellow trainees and the frequency of medical errors reported. A survey of pediatric fellows from 53 pediatric anesthesiology fellowship programs in the United States was performed. The primary outcome was the frequency of self-reported errors by fellows, and the primary independent variable was supervision scores. Questions also assessed barriers for effective faculty supervision. One hundred seventy-six pediatric anesthesiology fellows were invited to participate, and 104 (59%) responded to the survey. Nine of 103 (9%, 95% confidence interval [CI], 4%-16%) respondents reported performing procedures, on >1 occasion, for which they were not properly trained for. Thirteen of 101 (13%, 95% CI, 7%-21%) reported making >1 mistake with negative consequence to patients, and 23 of 104 (22%, 95% CI, 15%-31%) reported >1 medication error in the last year. There were no differences in median (interquartile range) supervision scores between fellows who reported >1 medication error compared to those reporting ≤1 errors (3.4 [3.0-3.7] vs 3.4 [3.1-3.7]; median difference, 0; 99% CI, -0.3 to 0.3; P = .96). Similarly, there were no differences in those who reported >1 mistake with negative patient consequences, 3.3 (3.0-3.7), compared with those who did not report mistakes with negative patient consequences (3.4 [3.3-3.7]; median difference, 0.1; 99% CI, -0.2 to 0.6; P = .35). We detected a high rate of self-reported medication errors in pediatric anesthesiology fellows in the United States

  3. Sci—Fri PM: Dosimetry—01: Radiation-induced refraction artefacts in the optical CT readout of polymer gel dosimeters

    International Nuclear Information System (INIS)

    Campbell, Warren G; Jirasek, Andrew; Wells, Derek M

    2014-01-01

    Polymer gel dosimeters (PGDs) are a desirable tool for the verification of advanced radiotherapy treatments. Fully 3D, deformable, and tissue-equivalent, the PGD polymerizes wherever it absorbs dose. To measure the dose absorbed by a PGD, optical computed tomography (CT) can be used to evaluate, in full 3D, the opacity distribution that coincides with polymerization. In addition to an increase in opacity with dose, an increase in refractive index (RI) is also known to occur in irradiated polymer gels. The increase in RI is slight and was previously assumed insignificant. This work reveals the effects that radiation-induced RI changes can have on the optical CT readout of PGDs. A fan-beam optical CT scanner was used to image a cylindrical PGD irradiated by a pair of 3×3 cm 2 , 6 MV photon beams in an orthogonal arrangement. Investigative scans were performed to evaluate refraction errors occurring: i) within the plane, and ii) out of the plane of the fan-beam. In-plane refraction was shown to cause distinct streaking artefacts along dose gradients (i.e. RI gradients) due to higher intensity rays being refracted into more opaque regions. Out-of-plane refraction was shown to produce severe, widespread artefacts due to rays missing the detector array. An iterative Savitzky-Golay filtering technique was developed to reduce both types of artefacts by specifically targeting structured errors in sinogram space. Results introduce a new category of imaging artefacts to be aware of when using optical CT for PGD readout

  4. Femtosecond laser refractive surgery: small-incision lenticule extraction vs. femtosecond laser-assisted LASIK.

    Science.gov (United States)

    Lee, Jimmy K; Chuck, Roy S; Park, Choul Yong

    2015-07-01

    Small-incision lenticule extraction (SMILE) is a novel technique devised to correct refractive errors. SMILE circumvents excimer laser photoablation of cornea, as the stromal lenticule cut by femtosecond laser is removed manually. Smaller incisions and preservation of anterior corneal biomechanical strength have been suggested as some of the advantages of SMILE over femtosecond laser-assisted LASIK (FS-LASIK). In this review, we compared previous published results of SMILE and FS-LASIK. The advantage, efficacy and safety of SMILE are compared with FS-LASIK. SMILE achieved similar efficacy, predictability and safety as FS-LASIK. Greater preservations of corneal biomechanical strength and corneal nerves were observed in SMILE when compared with LASIK or PRK. Additionally, the incidence of postoperative dry eye syndrome was found to be less problematic in SMILE than in FS-LASIK. SMILE is a promising new surgery for refractive error correction. Prospective and retrospective studies of SMILE have shown that results of SMILE are similar to FS-LASIK. With advances in femtosecond laser technology, SMILE may gain greater acceptance in the future.

  5. The Artisan Lens: Effects on Vision Quality, the Corneal Endothelium and Vision-Related Quality of Life

    NARCIS (Netherlands)

    R. Saxena (Ruchi)

    2009-01-01

    textabstractRefractive errors are the most frequent disorders of the eye. In the ideal refractive state, emmetropia, an image is focused directly on the retina, resulting in the perception of a sharp image in a healthy visual system. Such eyes do not require glasses or contact lenses to see sharply.

  6. Spherical subjective refraction with a novel 3D virtual reality based system.

    Science.gov (United States)

    Pujol, Jaume; Ondategui-Parra, Juan Carlos; Badiella, Llorenç; Otero, Carles; Vilaseca, Meritxell; Aldaba, Mikel

    To conduct a clinical validation of a virtual reality-based experimental system that is able to assess the spherical subjective refraction simplifying the methodology of ocular refraction. For the agreement assessment, spherical refraction measurements were obtained from 104 eyes of 52 subjects using three different methods: subjectively with the experimental prototype (Subj.E) and the classical subjective refraction (Subj.C); and objectively with the WAM-5500 autorefractor (WAM). To evaluate precision (intra- and inter-observer variability) of each refractive tool independently, 26 eyes were measured in four occasions. With regard to agreement, the mean difference (±SD) for the spherical equivalent (M) between the new experimental subjective method (Subj.E) and the classical subjective refraction (Subj.C) was -0.034D (±0.454D). The corresponding 95% Limits of Agreement (LoA) were (-0.856D, 0.924D). In relation to precision, intra-observer mean difference for the M component was 0.034±0.195D for the Subj.C, 0.015±0.177D for the WAM and 0.072±0.197D for the Subj.E. Inter-observer variability showed worse precision values, although still clinically valid (below 0.25D) in all instruments. The spherical equivalent obtained with the new experimental system was precise and in good agreement with the classical subjective routine. The algorithm implemented in this new system and its optical configuration has been shown to be a first valid step for spherical error correction in a semiautomated way. Copyright © 2016 Spanish General Council of Optometry. Published by Elsevier España, S.L.U. All rights reserved.

  7. The influence of the atmospheric refractive index on radio Xmax measurements of air showers

    Directory of Open Access Journals (Sweden)

    Corstanje Arthur

    2017-01-01

    Full Text Available The refractive index of the atmosphere, which is n ≈ 1:0003 at sea level, varies with altitude and with local temperature, pressure and humidity. When performing radio measurements of air showers, natural variations in n will change the radio lateral intensity distribution, by changing the Cherenkov angle. Using CoREAS simulations, we have evaluated the systematic error on measurements of the shower maximum Xmax due to variations in n. It was found that a 10% increase in refractivity (n – 1 leads to an underestimation of Xmax between 8 and 22 g/cm2 for proton-induced showers at zenith angles from 15 to 45 degrees, respectively.

  8. Assessment of multifocal contact lens over-refraction using an infrared, open-field autorefractor: A preliminary study.

    Science.gov (United States)

    Giner, Anna; Aldaba, Mikel; Arjona, Montserrat; Vilaseca, Meritxell; Pujol, Jaume

    2015-10-01

    To evaluate the usefulness of an infrared open-field autorefractor as a predictor of the refractive error when fitting multifocal contact lenses (MCL). Objective and subjective measurements of the non-cycloplegic distance refractive error were compared in patients wearing MCL. We used the Grand Seiko WAM-5500 autorefractor for the objective measurements. Three commercially available MCL were tested. Twenty-one eyes of sixteen healthy adults were included in the study. Over-refraction was evaluated in terms of spherical equivalent (SE) and astigmatic vectors (J0 and J45). The mean difference±SD of each parameter was calculated. The Kolmogorov-Smirnov test was used to verify the normal distribution. Pearson's correlation, Bland and Altman plot and paired sample t test were used to compare the results obtained with both methods. The mean difference between objective and subjective results of the SE over-refraction was 0.13±0.42D; for astigmatic vectors J0 and J45 were 0.03±0.32D and -0.00±0.17D, respectively. The Kolmogorov-Smirnov test showed a normal distribution for all parameters. The highest Pearson's correlation coefficients were obtained for the SE with values of 0.98 without MCL and 0.97 with MCL. The lowest were obtained for J45 with values of 0.65 without MCL and 0.75 with MCL. Significant correlations were obtained for each parameter. The paired sample t test failed to show significant differences in analyzed parameters except for J0 without MCL. The Grand Seiko WAM-5500 can be used as a screening method of over-refraction in the clinical fitting of MCL. Copyright © 2015 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  9. Refractive Errors

    Science.gov (United States)

    ... power glasses focus the light rays on the retina and improve vision. Myopia usually progresses yearly and stabilizes by the ... several points (in front and/or behind the retina). Near and distant vision is affected. Cylindrical power glasses are prescribed for ...

  10. Nanofocusing refractive X-ray lenses

    Energy Technology Data Exchange (ETDEWEB)

    Boye, Pit

    2010-02-05

    This thesis is concerned with the optimization and development of the production of nanofocusing refractive X-ray lenses. These optics made of either silicon or diamond are well-suited for high resolution X-ray microscopy. The goal of this work is the design of a reproducible manufacturing process which allows the production of silicon lenses with high precision, high quality and high piece number. Furthermore a process for the production of diamond lenses is to be developed and established. In this work, the theoretical basics of X-rays and their interaction with matter are described. Especially, aspects of synchrotron radiation are emphasized. Important in X-ray microscopy are the different optics. The details, advantages and disadvantages, in particular those of refractive lenses are given. To achieve small X-ray beams well beyond the 100 nm range a small focal length is required. This is achieved in refractive lenses by moving to a compact lens design where several single lenses are stacked behind each other. The, so-called nanofocusing refractive lenses (NFLs) have a parabolic cylindrical shape with lateral structure sizes in the micrometer range. NFLs are produced by using micro-machining techniques. These micro-fabrication processes and technologies are introduced. The results of the optimization and the final fabrication process for silicon lenses are presented. Subsequently, two experiments that are exemplary for the use of NFLs, are introduced. The rst one employs a high-resolution scanning fluorescence mapping of a geological sample, and the second one is a coherent x-ray diffraction imaging (CXDI) experiment. CXDI is able to reconstruct the illuminated object from recorded coherent diffraction patterns. In a scanning mode, referred to as ptychography, this method is even able to reconstruct the illumination and the object simultaneously. Especially the reconstructed illumination and the possibility of computed propagation of the wave field along the

  11. Nanofocusing refractive X-ray lenses

    International Nuclear Information System (INIS)

    Boye, Pit

    2010-01-01

    This thesis is concerned with the optimization and development of the production of nanofocusing refractive X-ray lenses. These optics made of either silicon or diamond are well-suited for high resolution X-ray microscopy. The goal of this work is the design of a reproducible manufacturing process which allows the production of silicon lenses with high precision, high quality and high piece number. Furthermore a process for the production of diamond lenses is to be developed and established. In this work, the theoretical basics of X-rays and their interaction with matter are described. Especially, aspects of synchrotron radiation are emphasized. Important in X-ray microscopy are the different optics. The details, advantages and disadvantages, in particular those of refractive lenses are given. To achieve small X-ray beams well beyond the 100 nm range a small focal length is required. This is achieved in refractive lenses by moving to a compact lens design where several single lenses are stacked behind each other. The, so-called nanofocusing refractive lenses (NFLs) have a parabolic cylindrical shape with lateral structure sizes in the micrometer range. NFLs are produced by using micro-machining techniques. These micro-fabrication processes and technologies are introduced. The results of the optimization and the final fabrication process for silicon lenses are presented. Subsequently, two experiments that are exemplary for the use of NFLs, are introduced. The rst one employs a high-resolution scanning fluorescence mapping of a geological sample, and the second one is a coherent x-ray diffraction imaging (CXDI) experiment. CXDI is able to reconstruct the illuminated object from recorded coherent diffraction patterns. In a scanning mode, referred to as ptychography, this method is even able to reconstruct the illumination and the object simultaneously. Especially the reconstructed illumination and the possibility of computed propagation of the wave field along the

  12. Retinopatia da prematuridade: achados refrativos pós-tratamento com crioterapia ou laser Retinopathy of prematurity: refractive errors in patients treated with cryotherapy or laser

    Directory of Open Access Journals (Sweden)

    Sara Pozzi

    2000-10-01

    Full Text Available Objetivos: Determinar e comparar as características refrativas de uma população composta de crianças pré-termo com retinopatia da prematuridade que necessitaram de tratamento com crioterapia ou laserterapia. Método: Análise dos resultados da refração estática de 14 pacientes (de um total de 761 fichas de crianças que nasceram no Hospital São Paulo da Universidade Federal de São Paulo - Escola Paulista de Medicina, entre janeiro de 1988 e abril de 1998, que completaram um ano de idade e que apresentaram Retinopatia da Prematuridade grau 3 com características de "doença limiar" sendo tratadas com crioterapia ou laserterapia. Foram utilizados os testes estatísticos de Wilcoxon e Mann-Whitney para a avaliação dos resultados. Resultados: 64,3% dos pacientes apresentaram miopia. No grupo de pacientes que receberam tratamento com crioterapia, 80% mostrou miopia, que em todos os casos foi alta; 20% hipermetropia leve, com uma média para o equivalente esférico de --3,10 D no olho direito e --3,25 D no olho esquerdo (diferença entre ambos os olhos estatísticamente não significante. No grupo de laserterapia, 55,6% mostrou miopia, sendo 20 % dos casos miopia alta e 80% miopia leve; 11,1% apresentou-se sem ametropia e 33,3 % com hipermetropia leve. O valor da média para o equivalente esférico foi --0,58 D no olho direito e --0,83D no olho esquerdo (diferença entre ambos os olhos estatisticamente significante. A comparação dos resultados refracionais dos dois grupos mostrou uma maior incidência para miopia alta no grupo de pacientes que receberam tratamento com crioterapia (PPurpose: To examine the spherical equivalent of refractive errors in preterm children with threshold retinopathy of prematurity treated with cryotherapy or laser. Patients and Method: A group of 14 one-year-old children (selected from 761 preterm children born at the Hospital São Paulo of the Universidade Federal de São Paulo between 1988 and 1998 with stage

  13. Quality controls in integrative approaches to detect errors and inconsistencies in biological databases

    Directory of Open Access Journals (Sweden)

    Ghisalberti Giorgio

    2010-12-01

    Full Text Available Numerous biomolecular data are available, but they are scattered in many databases and only some of them are curated by experts. Most available data are computationally derived and include errors and inconsistencies. Effective use of available data in order to derive new knowledge hence requires data integration and quality improvement. Many approaches for data integration have been proposed. Data warehousing seams to be the most adequate when comprehensive analysis of integrated data is required. This makes it the most suitable also to implement comprehensive quality controls on integrated data. We previously developed GFINDer (http://www.bioinformatics.polimi.it/GFINDer/, a web system that supports scientists in effectively using available information. It allows comprehensive statistical analysis and mining of functional and phenotypic annotations of gene lists, such as those identified by high-throughput biomolecular experiments. GFINDer backend is composed of a multi-organism genomic and proteomic data warehouse (GPDW. Within the GPDW, several controlled terminologies and ontologies, which describe gene and gene product related biomolecular processes, functions and phenotypes, are imported and integrated, together with their associations with genes and proteins of several organisms. In order to ease maintaining updated the GPDW and to ensure the best possible quality of data integrated in subsequent updating of the data warehouse, we developed several automatic procedures. Within them, we implemented numerous data quality control techniques to test the integrated data for a variety of possible errors and inconsistencies. Among other features, the implemented controls check data structure and completeness, ontological data consistency, ID format and evolution, unexpected data quantification values, and consistency of data from single and multiple sources. We use the implemented controls to analyze the quality of data available from several

  14. NQAR: Network Quality Aware Routing in Error-Prone Wireless Sensor Networks

    Directory of Open Access Journals (Sweden)

    Jaewon Choi

    2010-01-01

    Full Text Available We propose a network quality aware routing (NQAR mechanism to provide an enabling method of the delay-sensitive data delivery over error-prone wireless sensor networks. Unlike the existing routing methods that select routes with the shortest arrival latency or the minimum hop count, the proposed scheme adaptively selects the route based on the network qualities including link errors and collisions with minimum additional complexity. It is designed to avoid the paths with potential noise and collision that may cause many non-deterministic backoffs and retransmissions. We propose a generic framework to select a minimum cost route that takes the packet loss rate and collision history into account. NQAR uses a data centric approach to estimate a single-hop delay based on processing time, propagation delay, packet loss rate, number of backoffs, and the retransmission timeout between two neighboring nodes. This enables a source node to choose the shortest expected end-to-end delay path to send a delay-sensitive data. The experiment results show that NQAR reduces the end-to-end transfer delay up to approximately 50% in comparison with the latency-based directed diffusion and the hop count-based directed diffusion under the error-prone network environments. Moreover, NQAR shows better performance than those routing methods in terms of jitter, reachability, and network lifetime.

  15. Increased errors and decreased performance at night: A systematic review of the evidence concerning shift work and quality.

    Science.gov (United States)

    de Cordova, Pamela B; Bradford, Michelle A; Stone, Patricia W

    2016-02-15

    Shift workers have worse health outcomes than employees who work standard business hours. However, it is unclear how this poorer health shift may be related to employee work productivity. The purpose of this systematic review is to assess the relationship between shift work and errors and performance. Searches of MEDLINE/PubMed, EBSCOhost, and CINAHL were conducted to identify articles that examined the relationship between shift work, errors, quality, productivity, and performance. All articles were assessed for study quality. A total of 435 abstracts were screened with 13 meeting inclusion criteria. Eight studies were rated to be of strong, methodological quality. Nine studies demonstrated a positive relationship that night shift workers committed more errors and had decreased performance. Night shift workers have worse health that may contribute to errors and decreased performance in the workplace.

  16. Refractive errors in premature infants with retinopathy of prematurity after anti-vascular endothelial growth factor (anti-VEGF therapy

    Directory of Open Access Journals (Sweden)

    Vujanović Milena S.

    2017-01-01

    Full Text Available Background/Aim. Retinopathy of prematurity (ROP is a vasoproliferative retinopathy which affects the blood vessels of the retina during its development. The aim of this study was to evaluate the incidence and the degree of refractive errors in premature infants with severe ROP treated with antivascular endothelial growth factor (anti-VEGF (bevacizumab. Methods. This prospective study included 21 patients (42 eyes nine months old who received intravitreal injection of anti-VEGF therapy. The control group consisted of 45 patients (90 eyes who were subjected to laser treatment. In cycloplegia each patient underwent retinoscopy, keratorefractometry, and A-scan ultrasonography. Results. Myopia was present in 47.62% of the eyes in the study group and in 33.33% of the eyes in the control group, but there were no statistically significant differences between these groups. Seven (16.67% eyes in the study group and 17 (18.89% eyes in the control group were discovered to have high myopia (SE– spherical equivalents < -3.0 D – dioptre. Clinically significant hypermetropia was higher in the study group (47.62% than in the control group (34.44%, but with no statistically significant difference. In addition, high hypermetropia was significantly greater in the control group (15.56% than in the study group (11.90% (p < 0.001. Astigmatism was more common in the control group than in the study group (81.11% vs 71.43%, respectively, especially high astigmatism (56% vs 43%, respectively. Also the more common form of astigmatism was with the rule (WTR both in the study and the control group (42.86% vs 55.56%, respectively. Anisometropia was significantly greater in the control group (24.44% than in the study group (9.52% (p < 0.05. The children from the study group had significantly greater lens thickness, and a shorter anterior chamber depth than children from the control group (p < 0.01. There was no significant difference in the axial length of the eye between

  17. Parsimonious Refraction Interferometry and Tomography

    KAUST Repository

    Hanafy, Sherif; Schuster, Gerard T.

    2017-01-01

    We present parsimonious refraction interferometry and tomography where a densely populated refraction data set can be obtained from two reciprocal and several infill shot gathers. The assumptions are that the refraction arrivals are head waves

  18. Effects of the chromatic defocus caused by interchange of two monochromatic lights on refraction and ocular dimension in guinea pigs.

    Science.gov (United States)

    Qian, Yi-Feng; Dai, Jin-Hui; Liu, Rui; Chen, Min-Jie; Zhou, Xing-Tao; Chu, Ren-Yuan

    2013-01-01

    To investigate refractive and axial responses to the shift of focal plane resulting from the interchange of two monochromatic lights separately corresponding to the peak wavelengths of the cones absorption spectrum in retina, fifty 2-week-old pigmented guinea pigs were randomly assigned to five groups based on the mode of illumination: short-wavelength light (SL), middle-wavelength light (ML) and broad-band white light (BL) for 20 weeks, SL for 10 weeks followed by ML for 10 weeks (STM), as well as ML for 10 weeks followed by SL for 10 weeks (MTS). Biometric and refractive measurements were then performed every 2 weeks. After 10 weeks, SL and STM groups became more hyperopic and had less vitreous elongation than BL group. However, ML and MTS groups became more myopic and had more vitreous elongation. After interchange of the monochromatic light, the refractive error decreased rapidly by about 1.93D and the vitreous length increased by 0.14 mm in STM group from 10 to 12 weeks. After that, there were no significant intergroup differences between STM and BL groups. The interchange from ML to SL quickly increased the refractive error by about 1.53D and decreased the vitreous length by about 0.13 mm in MTS group after two weeks. At this time, there were also no significant intergroup differences between MTS and BL groups. The guinea pig eye can accurately detect the shift in focal plane caused by interchange of two monochromatic lights and rapidly generate refractive and axial responses. However, an excessive compensation was induced. Some properties of photoreceptors or retina may be changed by the monochromatic light to influence the following refractive development.

  19. What Time Is Sunrise? Revisiting the Refraction Component of Sunrise/set Prediction Models

    Science.gov (United States)

    Wilson, Teresa; Bartlett, Jennifer L.; Hilton, James Lindsay

    2017-01-01

    Algorithms that predict sunrise and sunset times currently have an error of one to four minutes at mid-latitudes (0° - 55° N/S) due to limitations in the atmospheric models they incorporate. At higher latitudes, slight changes in refraction can cause significant discrepancies, even including difficulties determining when the Sun appears to rise or set. While different components of refraction are known, how they affect predictions of sunrise/set has not yet been quantified. A better understanding of the contributions from temperature profile, pressure, humidity, and aerosols could significantly improve the standard prediction. We present a sunrise/set calculator that interchanges the refraction component by varying the refraction model. We then compare these predictions with data sets of observed rise/set times to create a better model. Sunrise/set times and meteorological data from multiple locations will be necessary for a thorough investigation of the problem. While there are a few data sets available, we will also begin collecting this data using smartphones as part of a citizen science project. The mobile application for this project will be available in the Google Play store. Data analysis will lead to more complete models that will provide more accurate rise/set times for the benefit of astronomers, navigators, and outdoorsmen everywhere.

  20. The refractive state of the eye in Icelandic horses with the Silver mutation.

    Science.gov (United States)

    Johansson, Maria K; Jäderkvist Fegraeus, Kim; Lindgren, Gabriella; Ekesten, Björn

    2017-06-02

    The syndrome Multiple Congenital Ocular Anomalies (MCOA) is a congenital eye disorder in horses. Both the MCOA syndrome and the Silver coat colour in horses are caused by the same missense mutation in the premelanosome protein (PMEL) gene. Horses homozygous for the Silver mutation (TT) are affected by multiple ocular defects causing visual impairment or blindness. Horses heterozygous for the Silver mutation (CT) have less severe clinical signs, usually cysts arising from the ciliary body iris or retina temporally. It is still unknown if the vision is impaired in horses heterozygous for the Silver mutation. A recent study reported that Comtois horses carrying the Silver mutation had significantly deeper anterior chambers of the eye compared to wild-type horses. This could potentially cause refractive errors. The purpose of the present study was to investigate if Icelandic horses with the Silver mutation have refractive errors compared to wild-type horses. One hundred and fifty-two Icelandic horses were included in the study, 71 CT horses and five TT horses. All horses were genotyped for the missense mutation in PMEL. Each CT and TT horse was matched by a wild-type (CC) horse of the same age ± 1 year. Skiascopy and a brief ophthalmic examination were performed in all horses. Association between refraction and age, eye, genotype and sex was tested by linear mixed-effect model analysis. TT horses with controls were not included in the statistical analyses as they were too few. The interaction between age and genotype had a significant impact on the refractive state (P = 0.0001). CT horses older than 16 years were on average more myopic than wild-type horses of the same age. No difference in the refractive state could be observed between genotypes (CT and CC) in horses younger than 16 years. TT horses were myopic (-2 D or more) in one or both eyes regardless of age. Our results indicate that an elderly Icelandic horse (older than 16 years) carrying the Silver

  1. Corneal densitometry and its correlation with age, pachymetry, corneal curvature, and refraction.

    Science.gov (United States)

    Garzón, Nuria; Poyales, Francisco; Illarramendi, Igor; Mendicute, Javier; Jáñez, Óscar; Caro, Pedro; López, Alfredo; Argüeso, Francisco

    2017-12-01

    To determine normative corneal densitometry values in relation to age, sex, refractive error, corneal thickness, and keratometry, measured using the Oculus Pentacam system. Three hundred and thirty-eight healthy subjects (185 men; 153 women) with no corneal disease underwent an exhaustive ocular examination. Corneal densitometry was expressed in standardized grayscale units (GSU). The mean corneal densitometry over the total area was 16.46 ± 1.85 GSU. The Pearson correlation coefficient for total densitometry was r = 0.542 (p  0.05). This is the first report of normative corneal densitometry values in relation to keratometry, corneal thickness, and spherical equivalent measured with the latest Oculus Pentacam software. Corneal densitometry increases with age, but corneal keratometry and refractive parameters do not affect light scattering in the human cornea.

  2. Remote sensing of refractivity from space for global observations of atmospheric parameters

    International Nuclear Information System (INIS)

    Gorbunov, M.E.; Sokolovskiy, S.V.

    1993-01-01

    This report presents the first results of computational simulations on the retrieval of meteorological parameters from space refractometric data on the basis of the ECHAM 3 model developed at the Max Planck Institute for Meteorology (Roeckner et al. 1992). For this purpose the grid fields of temperature, geopotential and humidity available from the model were interpolated and a continuous spatial field of refractivity (together with its first derivative) was generated. This field was used for calculating the trajectories of electromagnetic rays for the given orbits of transmitting and receiving satellites and for the determination of the quantities (incident angles or Doppler frequency shifts) being measured at receiving satellite during occultation. These quantities were then used for solving the inverse problem - retrieving the distribution of refractivity in the vicinity of the ray perigees. The retrieved refractivity was used to calculate pressure and temperature (using the hydrostatic equation and the equation of state). The results were compared with initial data, and the retrieval errors were evaluated. The study shows that the refractivity can be retrieved with very high accuracy in particular if a tomographic reconstruction is applied. Effects of humidity and temperature are not separable. Stratospheric temperatures globally and upper tropospheric temperatures at middle and high latitudes can be accurately retrieved, other areas require humidity data. Alternatively humidity data can be retrieved if the temperature fields are known. (orig.)

  3. Refractive-index determination of solids from first- and second-order critical diffraction angles of periodic surface patterns

    International Nuclear Information System (INIS)

    Meichner, Christoph; Kador, Lothar; Schedl, Andreas E.; Neuber, Christian; Kreger, Klaus; Schmidt, Hans-Werner

    2015-01-01

    We present two approaches for measuring the refractive index of transparent solids in the visible spectral range based on diffraction gratings. Both require a small spot with a periodic pattern on the surface of the solid, collimated monochromatic light, and a rotation stage. We demonstrate the methods on a polydimethylsiloxane film (Sylgard ® 184) and compare our data to those obtained with a standard Abbe refractometer at several wavelengths between 489 and 688 nm. The results of our approaches show good agreement with the refractometer data. Possible error sources are analyzed and discussed in detail; they include mainly the linewidth of the laser and/or the angular resolution of the rotation stage. With narrow-band light sources, an angular accuracy of ±0.025 ∘ results in an error of the refractive index of typically ±5 ⋅ 10 −4 . Information on the sample thickness is not required

  4. Deviations of Lambert-Beer???s law affect corneal refractive parameters after refractive surgery

    OpenAIRE

    Jim??nez Cuesta, Jos?? Ram??n; Rodr??guez-Mar??n, Francisco; Gonz??lez Anera, Rosario; Jim??nez del Barco Jaldo, Luis Miguel

    2006-01-01

    We calculate whether deviations of Lambert-Beer???s law, which regulates depth ablation during corneal ablation, significantly influence corneal refractive parameters after refractive surgery and whether they influence visual performance. For this, we compute a point-to-point correction on the cornea while assuming a non-linear (including a quadratic term) fit for depth ablation. Post-surgical equations for refractive parameters using a non-linear fit show significant differences with respect...

  5. Effects of the chromatic defocus caused by interchange of two monochromatic lights on refraction and ocular dimension in guinea pigs.

    Directory of Open Access Journals (Sweden)

    Yi-Feng Qian

    Full Text Available To investigate refractive and axial responses to the shift of focal plane resulting from the interchange of two monochromatic lights separately corresponding to the peak wavelengths of the cones absorption spectrum in retina, fifty 2-week-old pigmented guinea pigs were randomly assigned to five groups based on the mode of illumination: short-wavelength light (SL, middle-wavelength light (ML and broad-band white light (BL for 20 weeks, SL for 10 weeks followed by ML for 10 weeks (STM, as well as ML for 10 weeks followed by SL for 10 weeks (MTS. Biometric and refractive measurements were then performed every 2 weeks. After 10 weeks, SL and STM groups became more hyperopic and had less vitreous elongation than BL group. However, ML and MTS groups became more myopic and had more vitreous elongation. After interchange of the monochromatic light, the refractive error decreased rapidly by about 1.93D and the vitreous length increased by 0.14 mm in STM group from 10 to 12 weeks. After that, there were no significant intergroup differences between STM and BL groups. The interchange from ML to SL quickly increased the refractive error by about 1.53D and decreased the vitreous length by about 0.13 mm in MTS group after two weeks. At this time, there were also no significant intergroup differences between MTS and BL groups. The guinea pig eye can accurately detect the shift in focal plane caused by interchange of two monochromatic lights and rapidly generate refractive and axial responses. However, an excessive compensation was induced. Some properties of photoreceptors or retina may be changed by the monochromatic light to influence the following refractive development.

  6. Refractometry for quality control of anesthetic drug mixtures.

    Science.gov (United States)

    Stabenow, Jennifer M; Maske, Mindy L; Vogler, George A

    2006-07-01

    Injectable anesthetic drugs used in rodents are often mixed and further diluted to increase the convenience and accuracy of dosing. We evaluated clinical refractometry as a simple and rapid method of quality control and mixing error detection of rodent anesthetic or analgesic mixtures. Dilutions of ketamine, xylazine, acepromazine, and buprenorphine were prepared with reagent-grade water to produce at least 4 concentration levels. The refraction of each concentration then was measured with a clinical refractometer and plotted against the percentage of stock concentration. The resulting graphs were linear and could be used to determine the concentration of single-drug dilutions or to predict the refraction of drug mixtures. We conclude that refractometry can be used to assess the concentration of dilutions of single drugs and can verify the mixing accuracy of drug combinations when the components of the mixture are known and fall within the detection range of the instrument.

  7. Influence of refraction index strength on the light propagation in dielectrics material with periodic refraction index

    International Nuclear Information System (INIS)

    Hidayat, Arif; Latifah, Eny; Kurniati, Diana; Wisodo, Hari

    2016-01-01

    This study investigated the influence of refraction index strength on the light propagation in refraction index-varied dielectric material. This dielectric material served as photonic lattice. The behavior of light propagation influenced by variation of refraction index in photonic lattice was investigated. Modes of the guiding light were determined numerically using squared-operator iteration method. It was found that the greater the strength of refraction index, the smaller the guiding modes.

  8. MEDICAL AND SOCIAL VALUE OF AMETROPIA CORRECTION IN CHILDREN

    Directory of Open Access Journals (Sweden)

    E. Yu. Markova

    2015-01-01

    Full Text Available Aim. To analyze the impact of early ametropia detection on clinical and economic treatment aspects. Patients and methods. Retrospectively, quality of ophthalmological care in 60 children aged 6-8 with ametropia and strabismus was analyzed. All children were divided into three groups depending on age, refractive error and year at which treatment was initiated. In group 1 (30 children, refractive error and strabismus were diagnosed at the first year of life. In group 2 (18 children, refractive error and strabismus were diagnosed at the age of 1-3 years. In group 3 (12 children, glasses were prescribed at the age of 3-7 years. Retrospective analysis of primary medical records of enrolled patients was performed. All diagnostic and treatment methods that were applied as well as treatment results performed at the age of 6-8 were considered. The study of economic aspects considered the rates of ophthalmological examinations and pleoptic and orthoptic treatment courses as well as need in surgery. Direct medical costs were calculated for mediumterm prospects (3-5 years. Results. Early detection of refractive errors prevents amblyopia, binocular vision impairment, and strabismus. Uncorrected refractive errors in children are characterized by high economic and social burden (i.e., the higher is the age at which refractive error was revealed, the higher treatment costs are. Ametropia diagnosis in children requires special skills, hence, dilated eye exam must be performed by pediatric ophthalmologist but not by an orthoptist. Early diagnosis of refractive errors and strabismus provides accurate glass correction and timely therapy thus reducing treatment costs. Conclusions. In terms of clinical and economic efficacy, optimal age of refractive error detection is less than 1 year. Increase in diagnostic costs is compensated by good clinical outcomes and decrease in costs of managing complications and non-medical costs associated with reduced quality of life of

  9. Systematic errors in VLF direction-finding of whistler ducts

    International Nuclear Information System (INIS)

    Strangeways, H.J.; Rycroft, M.J.

    1980-01-01

    In the previous paper it was shown that the systematic error in the azimuthal bearing due to multipath propagation and incident wave polarisation (when this also constitutes an error) was given by only three different forms for all VLF direction-finders currently used to investigate the position of whistler ducts. In this paper the magnitude of this error is investigated for different ionospheric and ground parameters for these three different systematic error types. By incorporating an ionosphere for which the refractive index is given by the full Appleton-Hartree formula, the variation of the systematic error with ionospheric electron density and latitude and direction of propagation is investigated in addition to the variation with wave frequency, ground conductivity and dielectric constant and distance of propagation. The systematic bearing error is also investigated for the three methods when the azimuthal bearing is averaged over a 2 kHz bandwidth. This is found to lead to a significantly smaller bearing error which, for the crossed-loops goniometer, approximates the bearing error calculated when phase-dependent terms in the receiver response are ignored. (author)

  10. Parsimonious Refraction Interferometry and Tomography

    KAUST Repository

    Hanafy, Sherif

    2017-02-04

    We present parsimonious refraction interferometry and tomography where a densely populated refraction data set can be obtained from two reciprocal and several infill shot gathers. The assumptions are that the refraction arrivals are head waves, and a pair of reciprocal shot gathers and several infill shot gathers are recorded over the line of interest. Refraction traveltimes from these shot gathers are picked and spawned into O(N2) virtual refraction traveltimes generated by N virtual sources, where N is the number of geophones in the 2D survey. The virtual traveltimes can be inverted to give the velocity tomogram. This enormous increase in the number of traveltime picks and associated rays, compared to the many fewer traveltimes from the reciprocal and infill shot gathers, allows for increased model resolution and a better condition number with the system of normal equations. A significant benefit is that the parsimonious survey and the associated traveltime picking is far less time consuming than that for a standard refraction survey with a dense distribution of sources.

  11. Direct Electrospray Printing of Gradient Refractive Index Chalcogenide Glass Films.

    Science.gov (United States)

    Novak, Spencer; Lin, Pao Tai; Li, Cheng; Lumdee, Chatdanai; Hu, Juejun; Agarwal, Anuradha; Kik, Pieter G; Deng, Weiwei; Richardson, Kathleen

    2017-08-16

    A spatially varying effective refractive index gradient using chalcogenide glass layers is printed on a silicon wafer using an optimized electrospray (ES) deposition process. Using solution-derived glass precursors, IR-transparent Ge 23 Sb 7 S 70 and As 40 S 60 glass films of programmed thickness are fabricated to yield a bilayer structure, resulting in an effective gradient refractive index (GRIN) film. Optical and compositional analysis tools confirm the optical and physical nature of the gradient in the resulting high-optical-quality films, demonstrating the power of direct printing of multimaterial structures compatible with planar photonic fabrication protocols. The potential application of such tailorable materials and structures as they relate to the enhancement of sensitivity in chalcogenide glass based planar chemical sensor device design is presented. This method, applicable to a broad cross section of glass compositions, shows promise in directly depositing GRIN films with tunable refractive index profiles for bulk and planar optical components and devices.

  12. Refractive Results: Safety and Efficacy of Secondary Piggyback Sensar™ AR40 Intraocular Lens Implantation to Correct Pseudophakic Refractive Error

    Directory of Open Access Journals (Sweden)

    Alahmady Hamad Alsmman Hassan

    2016-01-01

    Full Text Available In this study we evaluate the visual outcomes, safety, efficacy, and stability of implanting of second sulcus intraocular lens (IOL to correct unsatisfied ametropic patients after phacoemulsification. Methods. Retrospective study of 15 eyes (15 patients underwent secondary intraocular lens implanted into the ciliary sulcus. The IOL used was a Sensar IOL three-piece foldable hydrophobic acrylic IOL. The first IOL in all patients was acrylic intrabagal IOL implanted in uncomplicated phacoemulsification surgery. Results. Fifteen eyes (15 patients were involved in this study. Preoperatively, mean log⁡MAR UDVA and CDVA were 0.88 ± 0.22 and 0.19 ± 0.13, respectively, with a mean follow-up of 28 months (range: 24 to 36 months. At the end of the follow-up, all eyes achieved log⁡MAR UDVA of 0.20 ± 0.12 with postoperative refraction ranging from 0.00 to −0.50 D of attempted emmetropia. Conclusions. Implantation of the second sulcus SensarAR40 IOL was found to be safe, easy, and simple technique for management of ametropia following uncomplicated phacoemulsification.

  13. Refining Sunrise/set Prediction Models by Accounting for the Effects of Refraction

    Science.gov (United States)

    Wilson, Teresa; Bartlett, Jennifer L.

    2016-01-01

    Current atmospheric models used to predict the times of sunrise and sunset have an error of one to four minutes at mid-latitudes (0° - 55° N/S). At higher latitudes, slight changes in refraction may cause significant discrepancies, including determining even whether the Sun appears to rise or set. While different components of refraction are known, how they affect predictions of sunrise/set has not yet been quantified. A better understanding of the contributions from temperature profile, pressure, humidity, and aerosols, could significantly improve the standard prediction. Because sunrise/set times and meteorological data from multiple locations will be necessary for a thorough investigation of the problem, we will collect this data using smartphones as part of a citizen science project. This analysis will lead to more complete models that will provide more accurate times for navigators and outdoorsman alike.

  14. A method to eliminate refraction artifacts in EM1002 multibeam echosounder system (Swath bathymetry and seabed surveys of EEZ)

    Digital Repository Service at National Institute of Oceanography (India)

    Fernandes, W.A.

    creating artificial features known as refraction artifacts. In 2007, we conducted an experiment off Goa region and collected multi-beam depth data and sound speed profiles. The reason for this experiment was to analyze the data, identify the errors...

  15. Improving axial resolution in confocal microscopy with new high refractive index mounting media.

    Science.gov (United States)

    Fouquet, Coralie; Gilles, Jean-François; Heck, Nicolas; Dos Santos, Marc; Schwartzmann, Richard; Cannaya, Vidjeacoumary; Morel, Marie-Pierre; Davidson, Robert Stephen; Trembleau, Alain; Bolte, Susanne

    2015-01-01

    Resolution, high signal intensity and elevated signal to noise ratio (SNR) are key issues for biologists who aim at studying the localisation of biological structures at the cellular and subcellular levels using confocal microscopy. The resolution required to separate sub-cellular biological structures is often near to the resolving power of the microscope. When optimally used, confocal microscopes may reach resolutions of 180 nm laterally and 500 nm axially, however, axial resolution in depth is often impaired by spherical aberration that may occur due to refractive index mismatches. Spherical aberration results in broadening of the point-spread function (PSF), a decrease in peak signal intensity when imaging in depth and a focal shift that leads to the distortion of the image along the z-axis and thus in a scaling error. In this study, we use the novel mounting medium CFM3 (Citifluor Ltd., UK) with a refractive index of 1.518 to minimize the effects of spherical aberration. This mounting medium is compatible with most common fluorochromes and fluorescent proteins. We compare its performance with established mounting media, harbouring refractive indices below 1.500, by estimating lateral and axial resolution with sub-resolution fluorescent beads. We show furthermore that the use of the high refractive index media renders the tissue transparent and improves considerably the axial resolution and imaging depth in immuno-labelled or fluorescent protein labelled fixed mouse brain tissue. We thus propose to use those novel high refractive index mounting media, whenever optimal axial resolution is required.

  16. Improving axial resolution in confocal microscopy with new high refractive index mounting media.

    Directory of Open Access Journals (Sweden)

    Coralie Fouquet

    Full Text Available Resolution, high signal intensity and elevated signal to noise ratio (SNR are key issues for biologists who aim at studying the localisation of biological structures at the cellular and subcellular levels using confocal microscopy. The resolution required to separate sub-cellular biological structures is often near to the resolving power of the microscope. When optimally used, confocal microscopes may reach resolutions of 180 nm laterally and 500 nm axially, however, axial resolution in depth is often impaired by spherical aberration that may occur due to refractive index mismatches. Spherical aberration results in broadening of the point-spread function (PSF, a decrease in peak signal intensity when imaging in depth and a focal shift that leads to the distortion of the image along the z-axis and thus in a scaling error. In this study, we use the novel mounting medium CFM3 (Citifluor Ltd., UK with a refractive index of 1.518 to minimize the effects of spherical aberration. This mounting medium is compatible with most common fluorochromes and fluorescent proteins. We compare its performance with established mounting media, harbouring refractive indices below 1.500, by estimating lateral and axial resolution with sub-resolution fluorescent beads. We show furthermore that the use of the high refractive index media renders the tissue transparent and improves considerably the axial resolution and imaging depth in immuno-labelled or fluorescent protein labelled fixed mouse brain tissue. We thus propose to use those novel high refractive index mounting media, whenever optimal axial resolution is required.

  17. School eye health – going beyond refractive errors

    Directory of Open Access Journals (Sweden)

    Sumrana Yasmin Regional

    2015-06-01

    Full Text Available Health, including visual health, is inextricably linked to school achievement, quality of life, and economic productivity. Introducing health education in schools is essential as knowledge and good habits acquired at an early age are likely to persist.

  18. The opportunistic screening of refractive errors in school-going children by pediatrician using enhanced Brückner test

    Directory of Open Access Journals (Sweden)

    Piyush Jain

    2016-01-01

    Full Text Available Aim: The aim of this study was to compare the results of enhanced Brückner test (EBT performed by a pediatrician and an experienced pediatric ophthalmologist. Subjects and Methods: In this prospective double-masked cohort study, a pediatrician and a pediatric ophthalmologist performed the EBT in a classroom of a school in semi-dark lighting condition using a direct ophthalmoscope. The results of the test were compared using 2 × 2 Bayesian table and kappa statistics. The findings of the pediatric ophthalmologists were considered gold standard. Results: Two hundred and thirty-six eyes of 118 subjects, mean age 6.8 ± 0.5 years (range, 5.4–7.8 years, were examined. The time taken to complete this test was <10 s per subject. The ophthalmologist identified 59 eyes as ametropic (12 hyperopic and 47 myopic eyes and 177 as emmetropic compared to 61 eyes as ametropic and 175 emmetropic by pediatrician. The prevalence of the test positive was 25.9%. The sensitivity of the pediatrician was 90.2%, specificity was 97.7%, predictive value of the positive test was 93.2%, and predictive value of the negative test was 96.6%. The clinical agreement (kappa between the pediatric ophthalmologist and the pediatrician was 0.9. Conclusion: The results of the EBT performed by pediatrician were comparable to that of an experienced pediatric ophthalmologist. Opportunistic screening of refractive errors using EBT by a pediatrician can be an important approach in the detection of ametropia in children.

  19. Application of super-virtual seismic refraction interferometry to enhance first arrivals: A case study from Saudi Arabia

    KAUST Repository

    Alshuhail, Abdulrahman Abdullatif Abdulrahman

    2012-01-01

    Complex near-surface anomalies are one of the main onshore challenges facing seismic data processors. Refraction tomography is becoming a common technology to estimate an accurate near-surface velocity model. This process involves picking the first arrivals of refracted waves. One of the main challenges with refraction tomography is the low signal-to-noise ratio characterizing the first-break waveform arrivals, especially for the far-offset receivers. This is especially evident in data recorded using reflection acquisition geometry. This low signal-to-noise ratio is caused by signal attenuation due to geometrical spreading of the seismic wavefield, near-surface-generated noise, and amplitude absorption. Super-virtual refraction interferometry improves the quality of the first-break picks by enhancing the amplitude of the refracted waves and attenuating the amplitude of the random noise.

  20. Sensitivity of the corneal-plane refractive compensation to change in power and axial position of an intraocular lens

    Directory of Open Access Journals (Sweden)

    W. F. Harris

    2009-12-01

    Full Text Available If an intraocular lens is displaced or if its power is changed what are the consequences for the refractive compensation of the eye?  Gaussian optics is used to obtain explicit formulae for the sensitivityof the corneal-plane refractive compensation (also called the refraction, refractive state, etc to change in power and axial displacement of a thin intraocular lens implanted in a simple eye.  In particular, for a pseudophakic Gullstrand simplified eye with intraocular lens placed 5 mm behind the cornea the sensitivity to errors in the power of the intraocular lens is about  71 . 0 − 71 for an intraocular lens of power   for an intraocular lens of power 20 D, that is, the refractive compensation decreases by about 0.71 dioptres per dioptre increase in the power of the intraocular lens.  More generally the sensitivity is approximately  ( m   0037 . 0 63 . 0 F − − 0.63 ( 003 . 0 63 . 0 − − (0.0037mF where FI is the power of the intraocular lens.  Also for Gullstrand’s simplified eye the sensitivity of refractive compensation to axial displacement of the intraocular lens is approximately linear in FI about  (64D FI, in fact.  That is, for each dioptre of the power of the intraocular lens the refractive compensation increases by about 0.064 dioptres per millimetre of axial displacement towards the retina. 

  1. Validity of automated refraction after segmented refractive multifocal intraocular lens implantation.

    Science.gov (United States)

    Albarrán-Diego, César; Muñoz, Gonzalo; Rohrweck, Stephanie; García-Lázaro, Santiago; Albero, José Ricardo

    2017-01-01

    To evaluate the clinical utility of automated refraction (AR) and keratometry (KR) compared with subjective or manifest refraction (MR) after cataract or refractive lens exchange surgery with implantation of Lentis Mplus X (Oculentis GmbH) refractive multifocal intraocular lens (IOL). Eighty-six eyes implanted with the Lentis Mplus X multifocal IOL were included. MR was performed in all patients followed by three consecutive AR measurements using the Topcon KR-8000 autorefractor. Assessment of repeatability of consecutive AR before and after dilation with phenylephrine 10%, and comparison of the AR and KR with MR using vector analysis were performed at 3mo follow-up. Analysis showed excellent repeatability of the AR measurements. Linear regression of AR versus MR showed good correlation for sphere and spherical equivalent, whereas the correlation for astigmatism was low. The mean difference AR-MR was -1.28±0.29 diopters (D) for sphere. Astigmatism showed better correlation between KR and MR. We suggest AR sphere plus 1.25 D and the KR cylinder as the starting point for MR in eyes with a Lentis Mplus X multifocal IOL. If AR measurements are equal to MR, decentration of the IOL should be suspected.

  2. Análise comparativa entre a refração clínica subjetiva e a automatizada obtida por sensor de frentes de onda Comparative analyses between clinical refraction and automatic refraction obtained through a wave front sensor

    Directory of Open Access Journals (Sweden)

    Wilson de Freitas

    2007-08-01

    Full Text Available OBJETIVO: Avaliar e comparar os resultados obtidos da refração estática clínica com a obtida por sensor de frentes de onda. MÉTODOS: Estudo prospectivo, não seqüencial, de 279 olhos de 147 pacientes. Todos os pacientes foram examinados sob cicloplegia. Primeiro realizamos a refração clínica e a seguir a automatizada por sensor de frentes de onda. Os dados refracionais obtidos foram decompostos para análise vetorial. Foram analisados separadamente os dados de um olho por paciente e dos dois olhos. RESULTADOS: A diferença entre a refração clínica e a automatizada foi de -0,19 DE combinada com -0,06 DC no eixo de 15º para os dados de um olho por paciente e -0,17 DE combinada com -0,05 DC no eixo de 3º para todos os olhos da amostra. CONCLUSÃO: Os dados da refração clínica são comparáveis com os da refração obtida por um sensor de frentes de onda.PURPOSE: To evaluate and compare refractive errors obtained through clinical subjective and automatized wavefront refraction analyses in eyes under cycloplegia. METHODS: Prospective study of 147 patients, 279 eyes, undergoing preoperative examination for refractive surgery. Clinical subjective refraction was performed first followed by wavefront refraction. Results on astigmatism obtained from refraction were decomposed in power vectors for statistical analyses. Data were first analyzed in one eye and then in both eyes. RESULTS: The mean difference between clinical subjective refraction and automatized wavefront refraction on cycloplegic eyes was of -0.19 SD combined with -0.06 CD in the 15º axis for data in one eye, and -0.17 SD combined with -0.05 CD in the 3º axis for data in both eyes of the same patient. CONCLUSION: In the present study clinical subjective refraction and automatized wavefront refraction under cycloplegia had similar numerical values.

  3. A Method to Optimize Geometric Errors of Machine Tool based on SNR Quality Loss Function and Correlation Analysis

    Directory of Open Access Journals (Sweden)

    Cai Ligang

    2017-01-01

    Full Text Available Instead improving the accuracy of machine tool by increasing the precision of key components level blindly in the production process, the method of combination of SNR quality loss function and machine tool geometric error correlation analysis to optimize five-axis machine tool geometric errors will be adopted. Firstly, the homogeneous transformation matrix method will be used to build five-axis machine tool geometric error modeling. Secondly, the SNR quality loss function will be used for cost modeling. And then, machine tool accuracy optimal objective function will be established based on the correlation analysis. Finally, ISIGHT combined with MATLAB will be applied to optimize each error. The results show that this method is reasonable and appropriate to relax the range of tolerance values, so as to reduce the manufacturing cost of machine tools.

  4. Monitoring of high refractive index edible oils using coated long period fiber grating sensors

    Science.gov (United States)

    Coelho, Luís.; Viegas, Diana; Santos, José Luís.; de Almeida, Jose Manuel M. M.

    2015-05-01

    Monitoring the quality of high refractive index edible oils is of great importance for the human health. Uncooked edible oils in general are healthy foodstuff, olive oil in particular, however, they are frequently used for baking and cooking. High quality edible oils are made from seeds, nuts or fruits by mechanical processes. Nevertheless, once the mechanical extraction is complete, up to 15% of the oil remains in oil pomace and in the mill wastewater, which can be extracted using organic solvents, often hexane. Optical fiber sensors based on long period fiber gratings (LPFG) have very low wavelength sensitivity when the surround refractive index is higher than the refractive index of the cladding. Titanium dioxide (TiO2) coated LPFG could lead to the realization of high sensitivity chemical sensor for the food industry. In this work LPFG coated with a TiO2 thin film were successfully used for to detect small levels of hexane diluted in edible oils and for real time monitoring the thermal deterioration of edible oils. For a TiO2 coating of 30 nm a wavelength sensitivity of 1361.7 nm/RIU (or 0.97 nm / % V/V) in the 1.4610-1.4670 refractive index range was achieved, corresponding to 0 to 12 % V/V of hexane in olive oil. A sensitivity higher than 638 nm/RIU at 225 ºC was calculated, in the 1.4670-1.4735 refractive index range with a detection limit of thermal deterioration of about 1 minute.

  5. A Hybrid Unequal Error Protection / Unequal Error Resilience ...

    African Journals Online (AJOL)

    The quality layers are then assigned an Unequal Error Resilience to synchronization loss by unequally allocating the number of headers available for synchronization to them. Following that Unequal Error Protection against channel noise is provided to the layers by the use of Rate Compatible Punctured Convolutional ...

  6. Prevalence of amblyopia and its association with refraction in Chinese preschool children aged 36-48 months.

    Science.gov (United States)

    Huang, Dan; Chen, Xuejuan; Zhu, Hui; Ding, Hui; Bai, Jing; Chen, Ji; Fu, Zhujun; Pan, Chen-Wei; Liu, Hu

    2018-06-01

    To determine the prevalence of amblyopia and its association with refraction in Chinese preschool children. The Yuhuatai Pediatric Eye Disease Study, a cross-sectional, population-based study, was conducted in children aged 36-48 months in Yuhuatai District, Nanjing, China, in 2015. Visual acuity was measured in 1695 eligible children. Of the 1695 subjects, manifested amblyopia was detected in 25 children (1.47%, 95% CI 0.90% to 2.05%), including 11 and 14 with bilateral and unilateral amblyopia, respectively. Amblyopia prevalence did not differ by gender (p=0.77). Significant refractive errors were found in 22 (88.0%) of children with amblyopia, and strabismus was found in 6 (24.0%) children with amblyopia. In multivariate analysis, amblyopia was significantly associated with hyperopia (≥+2.00 dioptres (D); OR 8.81, 95% CI 3.27 to 23.69, p<0.0001), astigmatism (≥2.00 D; OR 17.90, 95% CI 6.78 to 47.21, p<0.0001) and anisometropia (≥2.00 D; OR 5.87, 95% CI 1.52 to 22.77, p<0.05). The prevalence of amblyopia in children 36-48 months old in Eastern China was 1.47%. The refractive error is a major risk factor for amblyopia. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  7. Atmospheric refraction : a history

    NARCIS (Netherlands)

    Lehn, WH; van der Werf, S

    2005-01-01

    We trace the history of atmospheric refraction from the ancient Greeks up to the time of Kepler. The concept that the atmosphere could refract light entered Western science in the second century B.C. Ptolemy, 300 years later, produced the first clearly defined atmospheric model, containing air of

  8. Dried fruit breadfruit slices by Refractive Window™ technique

    Directory of Open Access Journals (Sweden)

    Diego F. Tirado

    2016-01-01

    Full Text Available A large amount of products are dried due several reasons as preservation, weight reduction and improvement of stability. However, on the market are not offered low-cost and high quality products simultaneously. Although there are effective methods of dehydrating foods such as freeze drying, which preserves the flavor, color and vitamins, they are poor accessibility technologies. Therefore, alternative processes are required to be efficient and economical. The aim of this research was compare drying kinetics of sliced of breadfruit (Artocarpus communis using the technique of Refractive Window® (VR with the tray drying. To carry out this study, sliced of 1 and 2 mm thick were used. Refractive window drying was performed with the water bath temperature to 92 °C; and tray drying at 62 °C and an air velocity of 0.52 m/s. During the Refractive window drying technique, the moisture content reached the lower than tray drying levels. Similarly it happened with samples of 1 mm, which, having a smaller diameter reached lower moisture levels than samples 2 mm. The higher diffusivities were obtained during drying sliced VR 1 and 2 mm with coefficients of 6.13 and 3.90*10-9 m2/s respectively.

  9. New infrared transmitting material via inverse vulcanization of elemental sulfur to prepare high refractive index polymers.

    Science.gov (United States)

    Griebel, Jared J; Namnabat, Soha; Kim, Eui Tae; Himmelhuber, Roland; Moronta, Dominic H; Chung, Woo Jin; Simmonds, Adam G; Kim, Kyung-Jo; van der Laan, John; Nguyen, Ngoc A; Dereniak, Eustace L; Mackay, Michael E; Char, Kookheon; Glass, Richard S; Norwood, Robert A; Pyun, Jeffrey

    2014-05-21

    Polymers for IR imaging: The preparation of high refractive index polymers (n = 1.75 to 1.86) via the inverse vulcanization of elemental sulfur is reported. High quality imaging in the near (1.5 μm) and mid-IR (3-5 μm) regions using high refractive index polymeric lenses from these sulfur materials was demonstrated. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. Negative refraction imaging of acoustic metamaterial lens in the supersonic range

    Directory of Open Access Journals (Sweden)

    Jianning Han

    2014-05-01

    Full Text Available Acoustic metamaterials with negative refraction index is the most promising method to overcome the diffraction limit of acoustic imaging to achieve ultrahigh resolution. In this paper, we use localized resonant phononic crystal as the unit cell to construct the acoustic negative refraction lens. Based on the vibration model of the phononic crystal, negative quality parameters of the lens are obtained while excited near the system resonance frequency. Simulation results show that negative refraction of the acoustic lens can be achieved when a sound wave transmiting through the phononic crystal plate. The patterns of the imaging field agree well with that of the incident wave, while the dispersion is very weak. The unit cell size in the simulation is 0.0005 m and the wavelength of the sound source is 0.02 m, from which we show that acoustic signal can be manipulated through structures with dimensions much smaller than the wavelength of incident wave.

  11. Relationship Between Patients' Perceptions of Care Quality and Health Care Errors in 11 Countries: A Secondary Data Analysis.

    Science.gov (United States)

    Hincapie, Ana L; Slack, Marion; Malone, Daniel C; MacKinnon, Neil J; Warholak, Terri L

    2016-01-01

    Patients may be the most reliable reporters of some aspects of the health care process; their perspectives should be considered when pursuing changes to improve patient safety. The authors evaluated the association between patients' perceived health care quality and self-reported medical, medication, and laboratory errors in a multinational sample. The analysis was conducted using the 2010 Commonwealth Fund International Health Policy Survey, a multinational consumer survey conducted in 11 countries. Quality of care was measured by a multifaceted construct developed using Rasch techniques. After adjusting for potentially important confounding variables, an increase in respondents' perceptions of care coordination decreased the odds of self-reporting medical errors, medication errors, and laboratory errors (P < .001). As health care stakeholders continue to search for initiatives that improve care experiences and outcomes, this study's results emphasize the importance of guaranteeing integrated care.

  12. Validity of automated refraction after segmented refractive multifocal intraocular lens implantation

    Directory of Open Access Journals (Sweden)

    César Albarrán-Diego

    2017-11-01

    Full Text Available AIM: To evaluate the clinical utility of automated refraction (AR and keratometry (KR compared with subjective or manifest refraction (MR after cataract or refractive lens exchange surgery with implantation of Lentis Mplus X (Oculentis GmbH refractive multifocal intraocular lens (IOL. METHODS: Eighty-six eyes implanted with the Lentis Mplus X multifocal IOL were included. MR was performed in all patients followed by three consecutive AR measurements using the Topcon KR-8000 autorefractor. Assessment of repeatability of consecutive AR before and after dilation with phenylephrine 10%, and comparison of the AR and KR with MR using vector analysis were performed at 3mo follow-up. RESULTS: Analysis showed excellent repeatability of the AR measurements. Linear regression of AR versus MR showed good correlation for sphere and spherical equivalent, whereas the correlation for astigmatism was low. The mean difference AR-MR was -1.28±0.29 diopters (D for sphere. Astigmatism showed better correlation between KR and MR. CONCLUSION: We suggest AR sphere plus 1.25 D and the KR cylinder as the starting point for MR in eyes with a Lentis Mplus X multifocal IOL. If AR measurements are equal to MR, decentration of the IOL should be suspected.

  13. Matching-index-of-refraction of transparent 3D printing models for flow visualization

    International Nuclear Information System (INIS)

    Song, Min Seop; Choi, Hae Yoon; Seong, Jee Hyun; Kim, Eung Soo

    2015-01-01

    Matching-index-of-refraction (MIR) has been used for obtaining high-quality flow visualization data for the fundamental nuclear thermal-hydraulic researches. By this method, distortions of the optical measurements such as PIV and LDV have been successfully minimized using various combinations of the model materials and the working fluids. This study investigated a novel 3D printing technology for manufacturing models and an oil-based working fluid for matching the refractive indices. Transparent test samples were fabricated by various rapid prototyping methods including selective layer sintering (SLS), stereolithography (SLA), and vacuum casting. As a result, the SLA direct 3D printing was evaluated to be the most suitable for flow visualization considering manufacturability, transparency, and refractive index. In order to match the refractive indices of the 3D printing models, a working fluid was developed based on the mixture of herb essential oils, which exhibit high refractive index, high transparency, high density, low viscosity, low toxicity, and low price. The refractive index and viscosity of the working fluid range 1.453–1.555 and 2.37–6.94 cP, respectively. In order to validate the MIR method, a simple test using a twisted prism made by the SLA technique and the oil mixture (anise and light mineral oil) was conducted. The experimental results show that the MIR can be successfully achieved at the refractive index of 1.51, and the proposed MIR method is expected to be widely used for flow visualization studies and CFD validation for the nuclear thermal-hydraulic researches

  14. Matching-index-of-refraction of transparent 3D printing models for flow visualization

    Energy Technology Data Exchange (ETDEWEB)

    Song, Min Seop; Choi, Hae Yoon; Seong, Jee Hyun; Kim, Eung Soo, E-mail: kes7741@snu.ac.kr

    2015-04-01

    Matching-index-of-refraction (MIR) has been used for obtaining high-quality flow visualization data for the fundamental nuclear thermal-hydraulic researches. By this method, distortions of the optical measurements such as PIV and LDV have been successfully minimized using various combinations of the model materials and the working fluids. This study investigated a novel 3D printing technology for manufacturing models and an oil-based working fluid for matching the refractive indices. Transparent test samples were fabricated by various rapid prototyping methods including selective layer sintering (SLS), stereolithography (SLA), and vacuum casting. As a result, the SLA direct 3D printing was evaluated to be the most suitable for flow visualization considering manufacturability, transparency, and refractive index. In order to match the refractive indices of the 3D printing models, a working fluid was developed based on the mixture of herb essential oils, which exhibit high refractive index, high transparency, high density, low viscosity, low toxicity, and low price. The refractive index and viscosity of the working fluid range 1.453–1.555 and 2.37–6.94 cP, respectively. In order to validate the MIR method, a simple test using a twisted prism made by the SLA technique and the oil mixture (anise and light mineral oil) was conducted. The experimental results show that the MIR can be successfully achieved at the refractive index of 1.51, and the proposed MIR method is expected to be widely used for flow visualization studies and CFD validation for the nuclear thermal-hydraulic researches.

  15. Refractive Development in the “ROP Rat”

    Directory of Open Access Journals (Sweden)

    Toco Y. P. Chui

    2012-01-01

    Full Text Available Although retinopathy of prematurity (ROP is clinically characterized by abnormal retinal vessels at the posterior pole of the eye, it is also commonly characterized by vascular abnormalities in the anterior segment, visual dysfunction which is based in retinal dysfunction, and, most commonly of all, arrested eye growth and high refractive error, particularly (and paradoxically myopia. The oxygen-induced retinopathy rat model of ROP presents neurovascular outcomes similar to the human disease, although it is not yet known if the “ROP rat” also models the small-eyed myopia characteristic of ROP. In this study, magnetic resonance images (MRIs of albino (Sprague-Dawley and pigmented (Long-Evans ROP rat eyes, and age- and strain-matched room-air-reared (RAR controls, were examined. The positions and curvatures of the various optical media were measured and the refractive state (℞ of each eye estimated based on a previously published model. Even in adulthood (postnatal day 50, Sprague-Dawley and Long-Evans ROP rats were significantly myopic compared to strain-matched controls. The myopia in the Long-Evans ROP rats was more severe than in the Sprague-Dawley ROP rats, which also had significantly shorter axial lengths. These data reveal the ROP rat to be a novel and potentially informative approach to investigating physiological mechanisms in myopia in general and the myopia peculiar to ROP in particular.

  16. EDITORIAL: Sensitive structures: refractive indices in nanotechnology Sensitive structures: refractive indices in nanotechnology

    Science.gov (United States)

    Demming, Anna

    2012-12-01

    Refractive index effects using nanoscale systems are frequently applied in new imaging, sensing and even visibility cloaking technology. In this issue, researchers in Japan use simulations and experiments to describe the confinement of optical vortices in nanoscale fin structures and the sensitivity of these systems to the refractive index of the surrounding media [1]. The effects of refraction as light rays pass between different media were recorded as long ago as the first century AD, by Ptolemy [2]. Over the following centuries the phenomena inspired Ibn Sahl in 984 [3], Thomas Harriot in 1602 [4], Willebrord Snellius in 1621 [5] and Rene Descartes in 1637 [6] to independently derive the more accurate and elegant equation for refraction so familiar to us today. Recent studies of the interactions between light and matter continue to reveal a wealth of phenomena that originate in the effects of the refractive indices of materials. Nanostructures can be used to manipulate conditions that affect the refractive indices of materials, such as temperature. A E Aliev et al at the University of Texas reported a striking demonstration of temperature-dependent refractive index effects using a free-standing, highly aligned carbon nanotube aerogel sheet [7]. They used the extremely low thermal capacitance and high heat transfer ability of transparent carbon nanotube sheets to enable high-frequency modulation of the sheet temperature over an enormous temperature range. The resulting sharp, rapidly changing gradient of the refractive index in the surrounding liquid or gas makes objects seem to disappear and can be used for visibility cloaking. Light-matter interaction resonances, where light is confined at the nanoscale, can be extremely sensitive to changes in the refractive index of the surrounding media [8], even allowing single-molecule detection [9]. Plasmons, the collective oscillations of electrons in response to incident light, are a typical example. Researchers at Rice

  17. Error analysis for mesospheric temperature profiling by absorptive occultation sensors

    Directory of Open Access Journals (Sweden)

    M. J. Rieder

    Full Text Available An error analysis for mesospheric profiles retrieved from absorptive occultation data has been performed, starting with realistic error assumptions as would apply to intensity data collected by available high-precision UV photodiode sensors. Propagation of statistical errors was investigated through the complete retrieval chain from measured intensity profiles to atmospheric density, pressure, and temperature profiles. We assumed unbiased errors as the occultation method is essentially self-calibrating and straight-line propagation of occulted signals as we focus on heights of 50–100 km, where refractive bending of the sensed radiation is negligible. Throughout the analysis the errors were characterized at each retrieval step by their mean profile, their covariance matrix and their probability density function (pdf. This furnishes, compared to a variance-only estimation, a much improved insight into the error propagation mechanism. We applied the procedure to a baseline analysis of the performance of a recently proposed solar UV occultation sensor (SMAS – Sun Monitor and Atmospheric Sounder and provide, using a reasonable exponential atmospheric model as background, results on error standard deviations and error correlation functions of density, pressure, and temperature profiles. Two different sensor photodiode assumptions are discussed, respectively, diamond diodes (DD with 0.03% and silicon diodes (SD with 0.1% (unattenuated intensity measurement noise at 10 Hz sampling rate. A factor-of-2 margin was applied to these noise values in order to roughly account for unmodeled cross section uncertainties. Within the entire height domain (50–100 km we find temperature to be retrieved to better than 0.3 K (DD / 1 K (SD accuracy, respectively, at 2 km height resolution. The results indicate that absorptive occultations acquired by a SMAS-type sensor could provide mesospheric profiles of fundamental variables such as temperature with

  18. Error analysis for mesospheric temperature profiling by absorptive occultation sensors

    Directory of Open Access Journals (Sweden)

    M. J. Rieder

    2001-01-01

    Full Text Available An error analysis for mesospheric profiles retrieved from absorptive occultation data has been performed, starting with realistic error assumptions as would apply to intensity data collected by available high-precision UV photodiode sensors. Propagation of statistical errors was investigated through the complete retrieval chain from measured intensity profiles to atmospheric density, pressure, and temperature profiles. We assumed unbiased errors as the occultation method is essentially self-calibrating and straight-line propagation of occulted signals as we focus on heights of 50–100 km, where refractive bending of the sensed radiation is negligible. Throughout the analysis the errors were characterized at each retrieval step by their mean profile, their covariance matrix and their probability density function (pdf. This furnishes, compared to a variance-only estimation, a much improved insight into the error propagation mechanism. We applied the procedure to a baseline analysis of the performance of a recently proposed solar UV occultation sensor (SMAS – Sun Monitor and Atmospheric Sounder and provide, using a reasonable exponential atmospheric model as background, results on error standard deviations and error correlation functions of density, pressure, and temperature profiles. Two different sensor photodiode assumptions are discussed, respectively, diamond diodes (DD with 0.03% and silicon diodes (SD with 0.1% (unattenuated intensity measurement noise at 10 Hz sampling rate. A factor-of-2 margin was applied to these noise values in order to roughly account for unmodeled cross section uncertainties. Within the entire height domain (50–100 km we find temperature to be retrieved to better than 0.3 K (DD / 1 K (SD accuracy, respectively, at 2 km height resolution. The results indicate that absorptive occultations acquired by a SMAS-type sensor could provide mesospheric profiles of fundamental variables such as temperature with

  19. Medical error reduction and tort reform through private, contractually-based quality medicine societies.

    Science.gov (United States)

    MacCourt, Duncan; Bernstein, Joseph

    2009-01-01

    physicians cede their implicit "right to remain silent", even if some injured patients will receive less than they do today. Likewise, physicians will be happier with a system that avoids blame-even if this system placed strict requirements for high quality care and disclosure of error. We therefore conceive of de facto trade between patients and physicians, a Pareto improvement, taking form via the establishment of "Societies of Quality Medicine." Physicians working within these societies would consent to onerous processes for disclosing, rectifying and preventing medical error. Patients would in turn contractually agree to assert their claims in arbitration and with limits on recovery. The role of plaintiffs' lawyers would be unchanged, but due to increased disclosure, discovery costs would diminish and the likelihood of prevailing will more than triple. This article examines the legal and policy issues surrounding the establishment of Societies of Quality Medicine, particularly the issues of contracting over liability, and outlines a means of overcoming the theoretical and practical difficulties with enterprise liability, alternative dispute resolution and the imposition of limits on recovery for non-pecuniary damages. We aim to build a welfare enhancing system that rebuffs the culture of silence and promotes error reduction, a system that is at the same time legally sound, fiscally prudent and politically possible.

  20. Errors associated with IOLMaster biometry as a function of internal ocular dimensions.

    Science.gov (United States)

    Faria-Ribeiro, Miguel; Lopes-Ferreira, Daniela; López-Gil, Norberto; Jorge, Jorge; González-Méijome, José Manuel

    2014-01-01

    To evaluate the error in the estimation of axial length (AL) with the IOLMaster partial coherence interferometry (PCI) biometer and obtain a correction factor that varies as a function of AL and crystalline lens thickness (LT). Optical simulations were produced for theoretical eyes using Zemax-EE software. Thirty-three combinations including eleven different AL (from 20mm to 30mm in 1mm steps) and three different LT (3.6mm, 4.2mm and 4.8mm) were used. Errors were obtained comparing the AL measured for a constant equivalent refractive index of 1.3549 and for the actual combinations of indices and intra-ocular dimensions of LT and AL in each model eye. In the range from 20mm to 30mm AL and 3.6-4.8mm LT, the instrument measurements yielded an error between -0.043mm and +0.089mm. Regression analyses for the three LT condition were combined in order to derive a correction factor as a function of the instrument measured AL for each combination of AL and LT in the theoretical eye. The assumption of a single "average" refractive index in the estimation of AL by the IOLMaster PCI biometer only induces very small errors in a wide range of combinations of ocular dimensions. Even so, the accurate estimation of those errors may help to improve accuracy of intra-ocular lens calculations through exact ray tracing, particularly in longer eyes and eyes with thicker or thinner crystalline lenses. Copyright © 2013 Spanish General Council of Optometry. Published by Elsevier Espana. All rights reserved.

  1. Complete Systematic Error Model of SSR for Sensor Registration in ATC Surveillance Networks.

    Science.gov (United States)

    Jarama, Ángel J; López-Araquistain, Jaime; Miguel, Gonzalo de; Besada, Juan A

    2017-09-21

    In this paper, a complete and rigorous mathematical model for secondary surveillance radar systematic errors (biases) is developed. The model takes into account the physical effects systematically affecting the measurement processes. The azimuth biases are calculated from the physical error of the antenna calibration and the errors of the angle determination dispositive. Distance bias is calculated from the delay of the signal produced by the refractivity index of the atmosphere, and from clock errors, while the altitude bias is calculated taking into account the atmosphere conditions (pressure and temperature). It will be shown, using simulated and real data, that adapting a classical bias estimation process to use the complete parametrized model results in improved accuracy in the bias estimation.

  2. Negative refraction angular characterization in one-dimensional photonic crystals.

    Directory of Open Access Journals (Sweden)

    Jesus Eduardo Lugo

    2011-04-01

    Full Text Available Photonic crystals are artificial structures that have periodic dielectric components with different refractive indices. Under certain conditions, they abnormally refract the light, a phenomenon called negative refraction. Here we experimentally characterize negative refraction in a one dimensional photonic crystal structure; near the low frequency edge of the fourth photonic bandgap. We compare the experimental results with current theory and a theory based on the group velocity developed here. We also analytically derived the negative refraction correctness condition that gives the angular region where negative refraction occurs.By using standard photonic techniques we experimentally determined the relationship between incidence and negative refraction angles and found the negative refraction range by applying the correctness condition. In order to compare both theories with experimental results an output refraction correction was utilized. The correction uses Snell's law and an effective refractive index based on two effective dielectric constants. We found good agreement between experiment and both theories in the negative refraction zone.Since both theories and the experimental observations agreed well in the negative refraction region, we can use both negative refraction theories plus the output correction to predict negative refraction angles. This can be very useful from a practical point of view for space filtering applications such as a photonic demultiplexer or for sensing applications.

  3. Negative refraction angular characterization in one-dimensional photonic crystals.

    Science.gov (United States)

    Lugo, Jesus Eduardo; Doti, Rafael; Faubert, Jocelyn

    2011-04-06

    Photonic crystals are artificial structures that have periodic dielectric components with different refractive indices. Under certain conditions, they abnormally refract the light, a phenomenon called negative refraction. Here we experimentally characterize negative refraction in a one dimensional photonic crystal structure; near the low frequency edge of the fourth photonic bandgap. We compare the experimental results with current theory and a theory based on the group velocity developed here. We also analytically derived the negative refraction correctness condition that gives the angular region where negative refraction occurs. By using standard photonic techniques we experimentally determined the relationship between incidence and negative refraction angles and found the negative refraction range by applying the correctness condition. In order to compare both theories with experimental results an output refraction correction was utilized. The correction uses Snell's law and an effective refractive index based on two effective dielectric constants. We found good agreement between experiment and both theories in the negative refraction zone. Since both theories and the experimental observations agreed well in the negative refraction region, we can use both negative refraction theories plus the output correction to predict negative refraction angles. This can be very useful from a practical point of view for space filtering applications such as a photonic demultiplexer or for sensing applications.

  4. Role of the treating surgeon in the consent process for elective refractive surgery

    Directory of Open Access Journals (Sweden)

    Schallhorn SC

    2016-11-01

    Full Text Available Steven C Schallhorn,1–3 Stephen J Hannan,3 David Teenan,3 Julie M Schallhorn1 1Department of Ophthalmology, University of California, San Francisco, San Francisco, 2Roski Eye Institute, University of Southern California, Los Angeles, CA, USA; 3Optical Express, Glasgow, UK Purpose: To compare patient’s perception of consent quality, clinical and quality-of-life outcomes after laser vision correction (LVC and refractive lens exchange (RLE between patients who met their treating surgeon prior to the day of surgery (PDOS or on the day of surgery (DOS. Design: Retrospective, comparative case series. Setting: Optical Express, Glasgow, UK. Methods: Patients treated between October 2015 and June 2016 (3972 LVC and 979 RLE patients who attended 1-day and 1-month postoperative aftercare and answered a questionnaire were included in this study. All patients had a thorough preoperative discussion with an optometrist, watched a video consent, and were provided with written information. Patients then had a verbal discussion with their treating surgeon either PDOS or on the DOS, according to patient preference. Preoperative and 1-month postoperative visual acuity, refraction, preoperative, 1-day and 1-month postoperative questionnaire were compared between DOS and PDOS patients. Multivariate regression model was developed to find factors associated with patient’s perception of consent quality. Results: Preoperatively, 8.0% of LVC and 17.1% of RLE patients elected to meet their surgeon ahead of the surgery day. In the LVC group, 97.5% of DOS and 97.2% of PDOS patients indicated they were properly consented for surgery (P=0.77. In the RLE group, 97.0% of DOS and 97.0% of PDOS patients stated their consent process for surgery was adequate (P=0.98. There was no statistically significant difference between DOS and PDOS patients in most of the postoperative clinical or questionnaire outcomes. Factors predictive of patient’s satisfaction with consent quality

  5. A global conformance quality model. A new strategic tool for minimizing defects caused by variation, error, and complexity

    Energy Technology Data Exchange (ETDEWEB)

    Hinckley, C. Martin [Sandia National Lab. (SNL-CA), Livermore, CA (United States)

    1994-01-01

    The performance of Japanese products in the marketplace points to the dominant role of quality in product competition. Our focus is motivated by the tremendous pressure to improve conformance quality by reducing defects to previously unimaginable limits in the range of 1 to 10 parts per million. Toward this end, we have developed a new model of conformance quality that addresses each of the three principle defect sources: (1) Variation, (2) Human Error, and (3) Complexity. Although the role of variation in conformance quality is well documented, errors occur so infrequently that their significance is not well known. We have shown that statistical methods are not useful in characterizing and controlling errors, the most common source of defects. Excessive complexity is also a root source of defects, since it increases errors and variation defects. A missing link in the defining a global model has been the lack of a sound correlation between complexity and defects. We have used Design for Assembly (DFA) methods to quantify assembly complexity and have shown that assembly times can be described in terms of the Pareto distribution in a clear exception to the Central Limit Theorem. Within individual companies we have found defects to be highly correlated with DFA measures of complexity in broad studies covering tens of millions of assembly operations. Applying the global concepts, we predicted that Motorola`s Six Sigma method would only reduce defects by roughly a factor of two rather than orders of magnitude, a prediction confirmed by Motorola`s data. We have also shown that the potential defects rates of product concepts can be compared in the earliest stages of development. The global Conformance Quality Model has demonstrated that the best strategy for improvement depends upon the quality control strengths and weaknesses.

  6. Wave-vector and polarization dependence of conical refraction.

    Science.gov (United States)

    Turpin, A; Loiko, Yu V; Kalkandjiev, T K; Tomizawa, H; Mompart, J

    2013-02-25

    We experimentally address the wave-vector and polarization dependence of the internal conical refraction phenomenon by demonstrating that an input light beam of elliptical transverse profile refracts into two beams after passing along one of the optic axes of a biaxial crystal, i.e. it exhibits double refraction instead of refracting conically. Such double refraction is investigated by the independent rotation of a linear polarizer and a cylindrical lens. Expressions to describe the position and the intensity pattern of the refracted beams are presented and applied to predict the intensity pattern for an axicon beam propagating along the optic axis of a biaxial crystal.

  7. Improving Papanicolaou test quality and reducing medical errors by using Toyota production system methods.

    Science.gov (United States)

    Raab, Stephen S; Andrew-Jaja, Carey; Condel, Jennifer L; Dabbs, David J

    2006-01-01

    The objective of the study was to determine whether the Toyota production system process improves Papanicolaou test quality and patient safety. An 8-month nonconcurrent cohort study that included 464 case and 639 control women who had a Papanicolaou test was performed. Office workflow was redesigned using Toyota production system methods by introducing a 1-by-1 continuous flow process. We measured the frequency of Papanicolaou tests without a transformation zone component, follow-up and Bethesda System diagnostic frequency of atypical squamous cells of undetermined significance, and diagnostic error frequency. After the intervention, the percentage of Papanicolaou tests lacking a transformation zone component decreased from 9.9% to 4.7% (P = .001). The percentage of Papanicolaou tests with a diagnosis of atypical squamous cells of undetermined significance decreased from 7.8% to 3.9% (P = .007). The frequency of error per correlating cytologic-histologic specimen pair decreased from 9.52% to 7.84%. The introduction of the Toyota production system process resulted in improved Papanicolaou test quality.

  8. Bayesian inversion of refraction seismic traveltime data

    Science.gov (United States)

    Ryberg, T.; Haberland, Ch

    2018-03-01

    We apply a Bayesian Markov chain Monte Carlo (McMC) formalism to the inversion of refraction seismic, traveltime data sets to derive 2-D velocity models below linear arrays (i.e. profiles) of sources and seismic receivers. Typical refraction data sets, especially when using the far-offset observations, are known as having experimental geometries which are very poor, highly ill-posed and far from being ideal. As a consequence, the structural resolution quickly degrades with depth. Conventional inversion techniques, based on regularization, potentially suffer from the choice of appropriate inversion parameters (i.e. number and distribution of cells, starting velocity models, damping and smoothing constraints, data noise level, etc.) and only local model space exploration. McMC techniques are used for exhaustive sampling of the model space without the need of prior knowledge (or assumptions) of inversion parameters, resulting in a large number of models fitting the observations. Statistical analysis of these models allows to derive an average (reference) solution and its standard deviation, thus providing uncertainty estimates of the inversion result. The highly non-linear character of the inversion problem, mainly caused by the experiment geometry, does not allow to derive a reference solution and error map by a simply averaging procedure. We present a modified averaging technique, which excludes parts of the prior distribution in the posterior values due to poor ray coverage, thus providing reliable estimates of inversion model properties even in those parts of the models. The model is discretized by a set of Voronoi polygons (with constant slowness cells) or a triangulated mesh (with interpolation within the triangles). Forward traveltime calculations are performed by a fast, finite-difference-based eikonal solver. The method is applied to a data set from a refraction seismic survey from Northern Namibia and compared to conventional tomography. An inversion test

  9. Complete Systematic Error Model of SSR for Sensor Registration in ATC Surveillance Networks

    Directory of Open Access Journals (Sweden)

    Ángel J. Jarama

    2017-09-01

    Full Text Available In this paper, a complete and rigorous mathematical model for secondary surveillance radar systematic errors (biases is developed. The model takes into account the physical effects systematically affecting the measurement processes. The azimuth biases are calculated from the physical error of the antenna calibration and the errors of the angle determination dispositive. Distance bias is calculated from the delay of the signal produced by the refractivity index of the atmosphere, and from clock errors, while the altitude bias is calculated taking into account the atmosphere conditions (pressure and temperature. It will be shown, using simulated and real data, that adapting a classical bias estimation process to use the complete parametrized model results in improved accuracy in the bias estimation.

  10. Postural stability changes in the elderly with cataract simulation and refractive blur.

    Science.gov (United States)

    Anand, Vijay; Buckley, John G; Scally, Andy; Elliott, David B

    2003-11-01

    maintaining postural stability. Correcting visual impairment caused by uncorrected refractive error and cataracts could be a useful intervention strategy to help prevent falls and fall-related injuries in the elderly.

  11. [Complications after refractive surgery abroad].

    Science.gov (United States)

    Terzi, E; Kern, T; Kohnen, T

    2008-05-01

    In this article a retrospective analysis of patients presenting at a German university following refractive surgery abroad is presented. A total of 20 cases of patients who had undergone treatment between 1998 and 2006 in China (1 case), Greece (1 case), Iran (1 case), Russia (2 cases), Switzerland (1 case), Slovakia (1 case), Spain (2 cases), South Africa (3 cases), Turkey (6 cases) and the USA (2 cases) were analyzed retrospectively. The following complications were observed: epithelial ingrowth into the interface with or without melting of the flap (6 cases), corneal ectasia (2 cases), dislocation of a phakic posterior chamber intraocular lens and prolapse into the anterior chamber with endothelial cell loss (1 case), secondary increase of intraocular pressure following implantation of a phakic intraocular lens (1 case), flap-related complications following laser-in-situ keratomileusis (LASIK) (2 cases), keratitis (1 case), dislocation of the complete flap (1 case), diffuse lamellar keratitis (DLK) grade IV (1 case), hyperopia as a consequence of radial keratotomy (1 case), and under correction/over correction and poor optical quality following laser epithelial keratomileusis (LASEK) and LASIK for high myopia (5 cases) with possible early corneal ectasia. There are four important problems arising from refractive surgery abroad, often referred to as "LASIK tourism": wrong indications, insufficient management of complications, lack of postoperative care and the health economic aspect.

  12. Stress evaluation of metallic material under steady state based on nonlinear critically refracted longitudinal wave

    Science.gov (United States)

    Mao, Hanling; Zhang, Yuhua; Mao, Hanying; Li, Xinxin; Huang, Zhenfeng

    2018-06-01

    This paper presents the study of applying the nonlinear ultrasonic wave to evaluate the stress state of metallic materials under steady state. The pre-stress loading method is applied to guarantee components with steady stress. Three kinds of nonlinear ultrasonic experiments based on critically refracted longitudinal wave are conducted on components which the critically refracted longitudinal wave propagates along x, x1 and x2 direction. Experimental results indicate the second and third order relative nonlinear coefficients monotonically increase with stress, and the normalized relationship is consistent with simplified dislocation models, which indicates the experimental result is logical. The combined ultrasonic nonlinear parameter is proposed, and three stress evaluation models at x direction are established based on three ultrasonic nonlinear parameters, which the estimation error is below 5%. Then two stress detection models at x1 and x2 direction are built based on combined ultrasonic nonlinear parameter, the stress synthesis method is applied to calculate the magnitude and direction of principal stress. The results show the prediction error is within 5% and the angle deviation is within 1.5°. Therefore the nonlinear ultrasonic technique based on LCR wave could be applied to nondestructively evaluate the stress of metallic materials under steady state which the magnitude and direction are included.

  13. Comparison of MLC error sensitivity of various commercial devices for VMAT pre-treatment quality assurance.

    Science.gov (United States)

    Saito, Masahide; Sano, Naoki; Shibata, Yuki; Kuriyama, Kengo; Komiyama, Takafumi; Marino, Kan; Aoki, Shinichi; Ashizawa, Kazunari; Yoshizawa, Kazuya; Onishi, Hiroshi

    2018-05-01

    The purpose of this study was to compare the MLC error sensitivity of various measurement devices for VMAT pre-treatment quality assurance (QA). This study used four QA devices (Scandidos Delta4, PTW 2D-array, iRT systems IQM, and PTW Farmer chamber). Nine retrospective VMAT plans were used and nine MLC error plans were generated for all nine original VMAT plans. The IQM and Farmer chamber were evaluated using the cumulative signal difference between the baseline and error-induced measurements. In addition, to investigate the sensitivity of the Delta4 device and the 2D-array, global gamma analysis (1%/1, 2%/2, and 3%/3 mm), dose difference (1%, 2%, and 3%) were used between the baseline and error-induced measurements. Some deviations of the MLC error sensitivity for the evaluation metrics and MLC error ranges were observed. For the two ionization devices, the sensitivity of the IQM was significantly better than that of the Farmer chamber (P < 0.01) while both devices had good linearly correlation between the cumulative signal difference and the magnitude of MLC errors. The pass rates decreased as the magnitude of the MLC error increased for both Delta4 and 2D-array. However, the small MLC error for small aperture sizes, such as for lung SBRT, could not be detected using the loosest gamma criteria (3%/3 mm). Our results indicate that DD could be more useful than gamma analysis for daily MLC QA, and that a large-area ionization chamber has a greater advantage for detecting systematic MLC error because of the large sensitive volume, while the other devices could not detect this error for some cases with a small range of MLC error. © 2018 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.

  14. Dark refraction shift with allowance for astigmatism

    Directory of Open Access Journals (Sweden)

    W.D.H. Gillan

    2005-12-01

    Full Text Available Purpose: To show that the dark refraction shift (dark focus is a more complicated phenomenon than implied when presented as spherical. Methods: Fifty autorefractor measurements of refractive state of the right eye were obtained in light  and  dark  conditions.  Multivariate  methods were used to analyze the data and stereo-pair scat-ter plots, polar meridional profiles and other means of presenting results are used to show important characteristics of the dark refraction shift. Results: The complexity of the dark refrac-tion shift is indicated by stereo-pair scatter plots showing the amount of stigmatic and antistigmatic variation that occurs in light and dark conditions. The mean dark refraction shift is presented in a complete manner including all three components of refractive state. The greater variance and covari-ance under dark conditions is clearly shown by the term-by-term dark-light variance-covariance ratio and polar profiles  of variance and covariance.Conclusions: The  dark  refraction  shift  is  a more complicated phenomenon than implied by representations as purely spherical in nature.

  15. Super-Virtual Refraction Interferometric Redatuming: Enhancing the Refracted Energy

    KAUST Repository

    Aldawood, Ali

    2012-02-26

    onshore seismic data processing. Refraction tomography is becoming a common way to estimate an accurate near surface velocity model. One of the problems with refraction tomography is the low signal to noise ration in far offset data. To improve, we propose using super-virtual refraction interferometry to enhance the weak energy at far offsets. We use Interferometric Green\\'s functions to redatum sources by cross-correlating two traces recorded at receiver stations, A and B, from a source at location W. The result is a redatumed trace with a virtual source at A and a receiver at B, which can also be obtained by correlating two traces recorded at A and B from different shots. Stacking them would enhance the signal-to-noise ratio of this "virtual" trace. We next augment redatuming with convolution and stacking. The trace recorded at B from a virtual source at A is convolved with the original trace recorded at A from a source at W. The result is a "super-virtual" trace at B in the far-offset from a source at W. Stacking N traces gives a vN-improvement. We applied our method to noisy synthetic and field data recorded over a complex near-surface and we could pick more traces at far offsets. It was possible to accommodate more picks resulting in a better subsurface coverage

  16. Super-Virtual Refraction Interferometric Redatuming: Enhancing the Refracted Energy

    KAUST Repository

    Aldawood, Ali; Alshuhail, Abdulrahman Abdullatif Abdulrahman; Hanafy, Sherif

    2012-01-01

    onshore seismic data processing. Refraction tomography is becoming a common way to estimate an accurate near surface velocity model. One of the problems with refraction tomography is the low signal to noise ration in far offset data. To improve, we propose using super-virtual refraction interferometry to enhance the weak energy at far offsets. We use Interferometric Green's functions to redatum sources by cross-correlating two traces recorded at receiver stations, A and B, from a source at location W. The result is a redatumed trace with a virtual source at A and a receiver at B, which can also be obtained by correlating two traces recorded at A and B from different shots. Stacking them would enhance the signal-to-noise ratio of this "virtual" trace. We next augment redatuming with convolution and stacking. The trace recorded at B from a virtual source at A is convolved with the original trace recorded at A from a source at W. The result is a "super-virtual" trace at B in the far-offset from a source at W. Stacking N traces gives a vN-improvement. We applied our method to noisy synthetic and field data recorded over a complex near-surface and we could pick more traces at far offsets. It was possible to accommodate more picks resulting in a better subsurface coverage

  17. Short-term impact of pictorial posters and a crash course on radiographic errors for improving the quality of paediatric chest radiographs in an unsupervised unit - a pilot study for quality-assurance outreach

    Energy Technology Data Exchange (ETDEWEB)

    Tebogo Hlabangana, Linda; Andronikou, Savvas [University of the Witwatersrand, Department of Diagnostic Radiology, Johannesburg (South Africa)

    2014-08-17

    Chest radiography is the most commonly performed diagnostic X-ray examination. The radiation dose to the patient for this examination is relatively low but because of its frequent use, the contribution to the collective dose is considerable. Optimized image quality not only allows for more accurate diagnosis but also supports radiation protection, which is particularly important in children. To determine whether the introduction of a poster of technical errors in paediatric radiography accompanied by a short lecture (crash course) for radiographers on common errors can sustainably decrease the number and rate of these errors in an unsupervised radiology department (without a paediatric-trained radiologist or paediatric-trained radiography personnel). We conducted a pilot study for quality-assurance outreach, with retrospective and prospective components, in the paediatric radiology department of a teaching hospital. The technical errors in frontal chest radiographs performed in the unit were assessed by quality-assurance analysis using a customized tick-sheet. The review was performed before and after an intervention that involved a half-hour crash course and poster displays in the department. We compared the rate of technical errors made before and after the intervention. There was statistically significant improvement in quality of radiographs (P < 0.0083) performed immediately after the intervention. There was a statistically significant decline in the quality of radiographs performed >2 months after the intervention. A simple intervention of a crash course and poster placement resulted in improved quality of paediatric chest radiographs. A decline in quality after 2 months suggests the need to repeat this or another type of intervention regularly. (orig.)

  18. Quality Assurance Analysis of a Large Multicenter Practice: Does Increased Complexity of Intensity-Modulated Radiotherapy Lead to Increased Error Frequency?

    International Nuclear Information System (INIS)

    Olson, Adam C.; Wegner, Rodney E.; Scicutella, Carol; Heron, Dwight E.; Greenberger, Joel S.; Huq, M. Saiful; Bednarz, Gregory; Flickinger, John C.

    2012-01-01

    Purpose: Error reduction is an important concern in clinical medicine. Intensity-modulated radiotherapy (IMRT) is an important advancement in radiation oncology that increases the complexity of treatment, potentially increasing the error risk. We studied the frequency and severity of errors in a large multicenter practice to ascertain the impact of quality improvement interventions over time, IMRT, and type of practice. Methods and Materials: We analyzed prospective data from three academic and 16 community practice sites with 24,775 courses of radiotherapy (9,210 IMRT courses and 15,565 non-IMRT) between January 2006 and December 2009. All IMRT treatment was performed using one centralized dose planning center for all sites. Results: We prospectively identified various errors or potential errors in 0.14 % vs. 0.40 % of the IMRT vs. non-IMRT courses (13/9,210 vs. 62/15,565, p = 0.0004) and excluding potential errors: 0.03 % for IMRT vs. 0.21% for non-IMRT. We developed the Clinical Radiotherapy Error Severity Scale (CRESS) to classify error severity from 1 to 10, with 1 to 3 for potential or completely correctable errors, 4 to 5 for dose variations 5%. Multivariate analyses of CRESS values, severity >4, and any error (including potential) correlated significantly reduced errors with IMRT (p = 0.0001–0.0024) but found no significant difference between the academic and community practice sites and no change in error frequency over time despite implementation of 39 system-wide policy changes by the centralized quality improvement committee. Conclusions: Despite the increase in complexity with IMRT compared with conventional radiotherapy, it can be delivered with reduced error frequency.

  19. Short-term impact of pictorial posters and a crash course on radiographic errors for improving the quality of paediatric chest radiographs in an unsupervised unit - a pilot study for quality-assurance outreach

    International Nuclear Information System (INIS)

    Tebogo Hlabangana, Linda; Andronikou, Savvas

    2015-01-01

    Chest radiography is the most commonly performed diagnostic X-ray examination. The radiation dose to the patient for this examination is relatively low but because of its frequent use, the contribution to the collective dose is considerable. Optimized image quality not only allows for more accurate diagnosis but also supports radiation protection, which is particularly important in children. To determine whether the introduction of a poster of technical errors in paediatric radiography accompanied by a short lecture (crash course) for radiographers on common errors can sustainably decrease the number and rate of these errors in an unsupervised radiology department (without a paediatric-trained radiologist or paediatric-trained radiography personnel). We conducted a pilot study for quality-assurance outreach, with retrospective and prospective components, in the paediatric radiology department of a teaching hospital. The technical errors in frontal chest radiographs performed in the unit were assessed by quality-assurance analysis using a customized tick-sheet. The review was performed before and after an intervention that involved a half-hour crash course and poster displays in the department. We compared the rate of technical errors made before and after the intervention. There was statistically significant improvement in quality of radiographs (P 2 months after the intervention. A simple intervention of a crash course and poster placement resulted in improved quality of paediatric chest radiographs. A decline in quality after 2 months suggests the need to repeat this or another type of intervention regularly. (orig.)

  20. Refracting surface plasmon polaritons with nanoparticle arrays

    DEFF Research Database (Denmark)

    Radko, I.P.; Evlyukhin, A.B.; Boltasseva, Alexandra

    2008-01-01

    Refraction of surface plasmon polaritons (SPPs) by various structures formed by a 100-nm-period square lattice of gold nanoparticles on top of a gold film is studied by leakage radiation microscopy. SPP refraction by a triangular-shaped nanoparticle array indicates that the SPP effective refractive...... to design nanoparticle arrays for specific applications requiring in-plane SPP manipulation....

  1. Measurement of the effective refractive index of a turbid colloidal suspension using light refraction

    International Nuclear Information System (INIS)

    Reyes-Coronado, A; Garcia-Valenzuela, A; Sanchez-Perez, C; Barrera, R G

    2005-01-01

    We propose and analyse a simple method to measure simultaneously the real and imaginary parts of the effective refractive index of a turbid suspension of particles. The method is based on measurements of the angle of refraction and transmittance of a laser beam that traverses a hollow glass prism filled with a colloidal suspension. We provide a comprehensive assessment of the method. It can offer high sensitivity while still being simple to interpret. We present results of experiments using an optically turbid suspension of polystyrene particles and compare them with theoretical predictions. We also report experimental evidence showing that the refractive behaviour of the diffuse component of light coming from a suspension depends on the volume fraction of the colloidal particles

  2. Refractive error changes in children with intermittent exotropia under overminus lens therapy Alterações nos vícios refracionais em crianças com exotropia intermitente submetidas ao tratamento por meio da hipercorreção com lentes negativas

    Directory of Open Access Journals (Sweden)

    Jayter Silva de Paula

    2009-12-01

    Full Text Available PURPOSE: Intermittent exotropia may be decreased by stimulation of accommodative convergence. Once excessive accommodation has been related to myopia, our objective was to evaluate refractive errors changes in children under overcorrecting minus lens therapy. METHODS: A retrospective chart review of 21 children with intermittent exotropia was performed. All patients were treated with occlusion, and a 13-patient subset of them received overminus lens therapy (group A. Eight children received spectacles as necessary (group B. Initial age, age interval, initial spherical equivalent (SE, and magnitude of overcorrection were considered as co-variables of the mean variation in refractive error (SE of each eye between groups, through a multivariate analysis. RESULTS: Overcorrection used in group A ranged from 0.5 D to 3.5 D (2.46 ± 0.87 D. Although initial SE of each eye was significant different between group A and B (OD - p=0.02; OS - p=0.01, initial age (p=0.69, age interval (p=0.90, and mean variation in refractive errors (p=0.36 did not differ between groups. Multivariate analysis with linear regression showed no significantly difference regarding all co-variables enrolled. CONCLUSIONS: Treatment of intermittent exotropia with overcorrecting minus lens did not induce refractive errors changes, even considering age, treatment period, initial spherical equivalent and overcorrection magnitude used.OBJETIVO: A exotropia intermitente pode ser diminuída pela estimulação da convergência acomodativa. Uma vez que uma acomodação excessiva tem sido relacionada à miopização, o objetivo deste trabalho foi o de avaliar alterações nos vícios de refração de crianças submetidas à hipercorreção com lentes negativas. MÉTODOS: Foi realizada revisão dos prontuários de 21 crianças com exotropia intermitente. Todos os pacientes foram tratados com oclusão, sendo que 13 deles foram submetidos à hipercorreção com lentes negativas (grupo A. As 8

  3. Analysis of the effects of Eye-Tracker performance on the pulse positioning errors during refractive surgery

    Directory of Open Access Journals (Sweden)

    Samuel Arba-Mosquera

    2012-01-01

    Conclusions: The proposed model can be used for comparison of laser systems used for ablation processes. Due to the pseudo-random nature of eye movements, positioning errors of single pulses are much larger than observed decentrations in the clinical settings. There is no single parameter that ‘alone’ minimizes the positioning error. It is the optimal combination of the several parameters that minimizes the error. The results of this analysis are important to understand the limitations of correcting very irregular ablation patterns.

  4. Compound refractive X-ray lens

    International Nuclear Information System (INIS)

    Nygren, D.R.; Cahn, R.; Cederstrom, B.; Danielsson, M.; Vestlund, J.

    2000-01-01

    An apparatus and method are disclosed for focusing X-rays. In one embodiment, his invention is a commercial-grade compound refractive X-ray lens. The commercial-grade compound refractive X-ray lens includes a volume of low-Z material. The volume of low-Z material has a first surface which is adapted to receive X-rays of commercially-applicable power emitted from a commercial-grade X-ray source. The volume of low-Z material also has a second surface from which emerge the X-rays of commercially-applicable power which were received at the first surface. Additionally, the commercial-grade compound refractive X-ray lens includes a plurality of openings which are disposed between the first surface and the second surface. The plurality of openings are oriented such that the X-rays of commercially-applicable power which are received at the first surface, pass through the volume of low-Z material and through the plurality openings. In so doing, the X-rays which emerge from the second surface are refracted to a focal point

  5. Compound refractive X-ray lens

    Science.gov (United States)

    Nygren, David R.; Cahn, Robert; Cederstrom, Bjorn; Danielsson, Mats; Vestlund, Jonas

    2000-01-01

    An apparatus and method for focusing X-rays. In one embodiment, his invention is a commercial-grade compound refractive X-ray lens. The commercial-grade compound refractive X-ray lens includes a volume of low-Z material. The volume of low-Z material has a first surface which is adapted to receive X-rays of commercially-applicable power emitted from a commercial-grade X-ray source. The volume of low-Z material also has a second surface from which emerge the X-rays of commercially-applicable power which were received at the first surface. Additionally, the commercial-grade compound refractive X-ray lens includes a plurality of openings which are disposed between the first surface and the second surface. The plurality of openings are oriented such that the X-rays of commercially-applicable power which are received at the first surface, pass through the volume of low-Z material and through the plurality openings. In so doing, the X-rays which emerge from the second surface are refracted to a focal point.

  6. The generalized vectorial laws of reflection and refraction

    International Nuclear Information System (INIS)

    Bhattacharjee, Pramode Ranjan

    2005-01-01

    This paper discloses two important discoveries. These are: (i) discovery of ambiguity in the well-established laws of reflection and refraction of light which have been in regular use for many years, and (ii) discovery of generalized vectorial laws of reflection and refraction of light. The existing definitions of angle of incidence, angle of reflection and angle of refraction are considered first. Each of these definitions is found to be ambiguous, not in compliance with the fundamental definition of angle in geometry. Two typical questions (one in the case of reflection and the other for refraction) have been addressed, which cannot be dealt with by using the existing laws of reflection and refraction of light. Thus, the existing laws of reflection and refraction of light seem to be ambiguous in respect of generality and their validity in a broad sense is questionable. With a view to removing the ambiguities, proper definitions of the above three angles are given first and then the statement of the generalized vectorial law of reflection (as well as that of refraction) has been offered

  7. Physics of negative refractive index materials

    International Nuclear Information System (INIS)

    Ramakrishna, S Anantha

    2005-01-01

    In the past few years, new developments in structured electromagnetic materials have given rise to negative refractive index materials which have both negative dielectric permittivity and negative magnetic permeability in some frequency ranges. The idea of a negative refractive index opens up new conceptual frontiers in photonics. One much-debated example is the concept of a perfect lens that enables imaging with sub-wavelength image resolution. Here we review the fundamental concepts and ideas of negative refractive index materials. First we present the ideas of structured materials or meta-materials that enable the design of new materials with a negative dielectric permittivity, negative magnetic permeability and negative refractive index. We discuss how a variety of resonance phenomena can be utilized to obtain these materials in various frequency ranges over the electromagnetic spectrum. The choice of the wave-vector in negative refractive index materials and the issues of dispersion, causality and energy transport are analysed. Various issues of wave propagation including nonlinear effects and surface modes in negative refractive materials (NRMs) are discussed. In the latter part of the review, we discuss the concept of a perfect lens consisting of a slab of a NRM. This perfect lens can image the far-field radiative components as well as the near-field evanescent components, and is not subject to the traditional diffraction limit. Different aspects of this lens such as the surface modes acting as the mechanism for the imaging of the evanescent waves, the limitations imposed by dissipation and dispersion in the negative refractive media, the generalization of this lens to optically complementary media and the possibility of magnification of the near-field images are discussed. Recent experimental developments verifying these ideas are briefly covered

  8. Error Analysis of Indirect Broadband Monitoring of Multilayer Optical Coatings using Computer Simulations

    Science.gov (United States)

    Semenov, Z. V.; Labusov, V. A.

    2017-11-01

    Results of studying the errors of indirect monitoring by means of computer simulations are reported. The monitoring method is based on measuring spectra of reflection from additional monitoring substrates in a wide spectral range. Special software (Deposition Control Simulator) is developed, which allows one to estimate the influence of the monitoring system parameters (noise of the photodetector array, operating spectral range of the spectrometer and errors of its calibration in terms of wavelengths, drift of the radiation source intensity, and errors in the refractive index of deposited materials) on the random and systematic errors of deposited layer thickness measurements. The direct and inverse problems of multilayer coatings are solved using the OptiReOpt library. Curves of the random and systematic errors of measurements of the deposited layer thickness as functions of the layer thickness are presented for various values of the system parameters. Recommendations are given on using the indirect monitoring method for the purpose of reducing the layer thickness measurement error.

  9. Parabolic refractive X-ray lenses: a breakthrough in X-ray optics

    CERN Document Server

    Lengeler, B; Benner, B; Guenzler, T F; Kuhlmann, M; Tümmler, J; Simionovici, A S; Drakopoulos, M; Snigirev, A; Snigireva, I

    2001-01-01

    Refractive X-ray lenses, considered for a long time as unfeasible, have been realized with a rotational parabolic profile at our institute: The main features of the new lenses are: they focus in two directions and are free of spherical aberration. By varying the number of individual lenses in the stack the focal length can be chosen in a typical range from 0.5 to 2 m for photon energies between about 6 and 60 keV. The aperture of the lens is about 1 mm matching the angular divergence of undulator beams at 3d generation synchrotron radiation sources. They cope without problems with the heat load from the white beam of an undulator. Finally, they are easy to align and to operate. Refractive X-ray lenses can be used with hard X-rays in the same way as glass lenses can be used for visible light, if it is take into account that the numerical aperture is small (of the order 10 sup - sup 4). Being high-quality optical elements, the refractive X-ray lenses can be used for generating a focal spot in the mu m range wit...

  10. Development of a subjective refraction simulator

    Science.gov (United States)

    Perches, S.; Ares, J.; Collados, M. V.

    2013-11-01

    We have developed simulation software by Matlab (MathworksInc.) with a graphical interface designed for non-expert users. This simulator allows you to complete the process of subjective refraction starting from the aberrometry of the patients and analyse the influence of different factors during the exam. In addition to explain the graphical interface and its working, we show two examples about a complete process of subjective refraction with the influence of high order aberrations and without them showing the retinal image obtained in each step of the refraction process. When the Jackson Cross-Cylinder technique is made with this software, it becomes clear the difficulty of chosen between two images when high order aberrations are present. Therefore, the variability of response during the refraction can be a problem when the examiner has to reach an adequate optical prescription.

  11. Isaac Newton and the astronomical refraction.

    Science.gov (United States)

    Lehn, Waldemar H

    2008-12-01

    In a short interval toward the end of 1694, Isaac Newton developed two mathematical models for the theory of the astronomical refraction and calculated two refraction tables, but did not publish his theory. Much effort has been expended, starting with Biot in 1836, in the attempt to identify the methods and equations that Newton used. In contrast to previous work, a closed form solution is identified for the refraction integral that reproduces the table for his first model (in which density decays linearly with elevation). The parameters of his second model, which includes the exponential variation of pressure in an isothermal atmosphere, have also been identified by reproducing his results. The implication is clear that in each case Newton had derived exactly the correct equations for the astronomical refraction; furthermore, he was the first to do so.

  12. Quality Indicators in Laboratory Medicine: from theory to practice. Preliminary data from the IFCC Working Group Project "Laboratory Errors and Patient Safety".

    Science.gov (United States)

    Sciacovelli, Laura; O'Kane, Maurice; Skaik, Younis Abdelwahab; Caciagli, Patrizio; Pellegrini, Cristina; Da Rin, Giorgio; Ivanov, Agnes; Ghys, Timothy; Plebani, Mario

    2011-05-01

    The adoption of Quality Indicators (QIs) has prompted the development of tools to measure and evaluate the quality and effectiveness of laboratory testing, first in the hospital setting and subsequently in ambulatory and other care settings. While Laboratory Medicine has an important role in the delivery of high-quality care, no consensus exists as yet on the use of QIs focussing on all steps of the laboratory total testing process (TTP), and further research in this area is required. In order to reduce errors in laboratory testing, the IFCC Working Group on "Laboratory Errors and Patient Safety" (WG-LEPS) developed a series of Quality Indicators, specifically designed for clinical laboratories. In the first phase of the project, specific QIs for key processes of the TTP were identified, including all the pre-, intra- and post-analytic steps. The overall aim of the project is to create a common reporting system for clinical laboratories based on standardized data collection, and to define state-of-the-art and Quality Specifications (QSs) for each QI independent of: a) the size of organization and type of activities; b) the complexity of processes undertaken; and c) different degree of knowledge and ability of the staff. The aim of the present paper is to report the results collected from participating laboratories from February 2008 to December 2009 and to identify preliminary QSs. The results demonstrate that a Model of Quality Indicators managed as an External Quality Assurance Program can serve as a tool to monitor and control the pre-, intra- and post-analytical activities. It might also allow clinical laboratories to identify risks that lead to errors resulting in patient harm: identification and design of practices that eliminate medical errors; the sharing of information and education of clinical and laboratory teams on practices that reduce or prevent errors; the monitoring and evaluation of improvement activities.

  13. 3D super-virtual refraction interferometry

    KAUST Repository

    Lu, Kai; AlTheyab, Abdullah; Schuster, Gerard T.

    2014-01-01

    Super-virtual refraction interferometry enhances the signal-to-noise ratio of far-offset refractions. However, when applied to 3D cases, traditional 2D SVI suffers because the stationary positions of the source-receiver pairs might be any place

  14. Postural stability in the elderly during sensory perturbations and dual tasking: the influence of refractive blur.

    Science.gov (United States)

    Anand, Vijay; Buckley, John G; Scally, Andy; Elliott, David B

    2003-07-01

    To determine the influence of refractive blur on postural stability during somatosensory and vestibular system perturbation and dual tasking. Fifteen healthy, elderly subjects (mean age, 71 +/- 5 years), who had no history of falls and had normal vision, were recruited. Postural stability during standing was assessed using a force platform, and was determined as the root mean square (RMS) of the center of pressure (COP) signal in the anterior-posterior (A-P) and medial-lateral directions collected over a 30-second period. Data were collected under normal standing conditions and with somatosensory and vestibular system perturbations. Measurements were repeated with an additional physical and/or cognitive task. Postural stability was measured under conditions of binocular refractive blur of 0, 1, 2, 4, and 8 D and with eyes closed. The data were analyzed with a population-averaged linear model. The greatest increases in postural instability were due to disruptions of the somatosensory and vestibular systems. Increasing refractive blur caused increasing postural instability, and its effect was greater when the input from the other sensory systems was disrupted. Performing an additional cognitive and physical task increased A-P RMS COP further. All these detrimental effects on postural stability were cumulative. The findings highlight the multifactorial nature of postural stability and indicate why the elderly, many of whom have poor vision and musculoskeletal and central nervous system degeneration, are at greater risk of falling. The findings also highlight that standing instability in both normal and perturbed conditions was significantly increased with refractive blur. Correcting visual impairment caused by uncorrected refractive error could be a useful intervention strategy to help prevent falls and fall-related injuries in the elderly.

  15. A RICH with aerogel: a study of refractive index uniformity

    CERN Document Server

    Alemi, M; Calvi, M; Matteuzzi, C; Musy, M; Perego, D L; Easo, S

    2004-01-01

    The use of aerogel as a radiator in the RICH detectors of LHCb is a challenge due to the hot environment of the hadron collider LHC. Large size tiles of silica aerogel were recently produced with unprecedented optical quality for such dimensions. Results of laboratory measurements and beam tests are briefly reported. A description of a method to measure the uniformity of the index of refraction within the tile is given.

  16. The refractive index of relic gravitons

    CERN Document Server

    Giovannini, Massimo

    2016-01-01

    The dynamical evolution of the refractive index of the tensor modes of the geometry produces a specific class of power spectra characterized by a blue (i.e. slightly increasing) slope which is directly determined by the competition of the slow-roll parameter and of the rate of variation of the refractive index. Throughout the conventional stages of the inflationary and post-inflationary evolution, the microwave background anisotropies measurements, the pulsar timing limits and the big-bang nucleosythesis constraints set stringent bounds on the refractive index and on its rate of variation. Within the physically allowed region of the parameter space the cosmic background of relic gravitons leads to a potentially large signal for the ground based detectors (in their advanced version) and for the proposed space-borne interferometers. Conversely, the lack of direct detection of the signal will set a qualitatively new bound on the dynamical variation of the refractive index.

  17. Medication Errors in Pediatric Anesthesia: A Report From the Wake Up Safe Quality Improvement Initiative.

    Science.gov (United States)

    Lobaugh, Lauren M Y; Martin, Lizabeth D; Schleelein, Laura E; Tyler, Donald C; Litman, Ronald S

    2017-09-01

    Wake Up Safe is a quality improvement initiative of the Society for Pediatric Anesthesia that contains a deidentified registry of serious adverse events occurring in pediatric anesthesia. The aim of this study was to describe and characterize reported medication errors to find common patterns amenable to preventative strategies. In September 2016, we analyzed approximately 6 years' worth of medication error events reported to Wake Up Safe. Medication errors were classified by: (1) medication category; (2) error type by phase of administration: prescribing, preparation, or administration; (3) bolus or infusion error; (4) provider type and level of training; (5) harm as defined by the National Coordinating Council for Medication Error Reporting and Prevention; and (6) perceived preventability. From 2010 to the time of our data analysis in September 2016, 32 institutions had joined and submitted data on 2087 adverse events during 2,316,635 anesthetics. These reports contained details of 276 medication errors, which comprised the third highest category of events behind cardiac and respiratory related events. Medication errors most commonly involved opioids and sedative/hypnotics. When categorized by phase of handling, 30 events occurred during preparation, 67 during prescribing, and 179 during administration. The most common error type was accidental administration of the wrong dose (N = 84), followed by syringe swap (accidental administration of the wrong syringe, N = 49). Fifty-seven (21%) reported medication errors involved medications prepared as infusions as opposed to 1 time bolus administrations. Medication errors were committed by all types of anesthesia providers, most commonly by attendings. Over 80% of reported medication errors reached the patient and more than half of these events caused patient harm. Fifteen events (5%) required a life sustaining intervention. Nearly all cases (97%) were judged to be either likely or certainly preventable. Our findings

  18. Fabrication of rigid and flexible refractive-index-matched flow phantoms for flow visualisation and optical flow measurements

    Science.gov (United States)

    Geoghegan, P. H.; Buchmann, N. A.; Spence, C. J. T.; Moore, S.; Jermy, M.

    2012-05-01

    A method for the construction of both rigid and compliant (flexible) transparent flow phantoms of biological flow structures, suitable for PIV and other optical flow methods with refractive-index-matched working fluid is described in detail. Methods for matching the in vivo compliance and elastic wave propagation wavelength are presented. The manipulation of MRI and CT scan data through an investment casting mould is described. A method for the casting of bubble-free phantoms in silicone elastomer is given. The method is applied to fabricate flexible phantoms of the carotid artery (with and without stenosis), the carotid artery bifurcation (idealised and patient-specific) and the human upper airway (nasal cavity). The fidelity of the phantoms to the original scan data is measured, and it is shown that the cross-sectional error is less than 5% for phantoms of simple shape but up to 16% for complex cross-sectional shapes such as the nasal cavity. This error is mainly due to the application of a PVA coating to the inner mould and can be reduced by shrinking the digital model. Sixteen per cent variation in area is less than the natural patient to patient variation of the physiological geometries. The compliance of the phantom walls is controlled within physiologically realistic ranges, by choice of the wall thickness, transmural pressure and Young's modulus of the elastomer. Data for the dependence of Young's modulus on curing temperature are given for Sylgard 184. Data for the temperature dependence of density, viscosity and refractive index of the refractive-index-matched working liquid (i.e. water-glycerol mixtures) are also presented.

  19. Reflective and refractive objects for mixed reality.

    Science.gov (United States)

    Knecht, Martin; Traxler, Christoph; Winklhofer, Christoph; Wimmer, Michael

    2013-04-01

    In this paper, we present a novel rendering method which integrates reflective or refractive objects into a differential instant radiosity (DIR) framework usable for mixed-reality (MR) applications. This kind of objects are very special from the light interaction point of view, as they reflect and refract incident rays. Therefore they may cause high-frequency lighting effects known as caustics. Using instant-radiosity (IR) methods to approximate these high-frequency lighting effects would require a large amount of virtual point lights (VPLs) and is therefore not desirable due to real-time constraints. Instead, our approach combines differential instant radiosity with three other methods. One method handles more accurate reflections compared to simple cubemaps by using impostors. Another method is able to calculate two refractions in real-time, and the third method uses small quads to create caustic effects. Our proposed method replaces parts in light paths that belong to reflective or refractive objects using these three methods and thus tightly integrates into DIR. In contrast to previous methods which introduce reflective or refractive objects into MR scenarios, our method produces caustics that also emit additional indirect light. The method runs at real-time frame rates, and the results show that reflective and refractive objects with caustics improve the overall impression for MR scenarios.

  20. Accommodation: The role of the external muscles of the eye: A consideration of refractive errors in relation to extraocular malfunction.

    Science.gov (United States)

    Hargrave, B K

    2014-11-01

    Speculation as to optical malfunction has led to dissatisfaction with the theory that the lens is the sole agent in accommodation and to the suggestion that other parts of the eye are also conjointly involved. Around half-a-century ago, Robert Brooks Simpkins suggested that the mechanical features of the human eye were precisely such as to allow for a lengthening of the globe when the eye accommodated. Simpkins was not an optical man but his theory is both imaginative and comprehensive and deserves consideration. It is submitted here that accommodation is in fact a twofold process, and that although involving the lens, is achieved primarily by means of a give - and - take interplay between adducting and abducting external muscles, whereby an elongation of the eyeball is brought about by a stretching of the delicate elastic fibres immediately behind the cornea. The three muscles responsible for convergence (superior, internal and inferior recti) all pull from in front backwards, while of the three abductors (external rectus and the two obliques) the obliques pull from behind forwards, allowing for an easy elongation as the eye turns inwards and a return to its original length as the abducting muscles regain their former tension, returning the eye to distance vision. In refractive errors, the altered length of the eyeball disturbs the harmonious give - and - take relationship between adductors and abductors. Such stresses are likely to be perpetuated and the error exacerbated. Speculation is not directed towards a search for a possible cause of the muscular imbalance, since none is suspected. Muscles not used rapidly lose tone, as evidenced after removal of a limb from plaster. Early attention to the need for restorative exercise is essential and results usually impressive. If flexibility of the external muscles of the eyes is essential for continuing good sight, presbyopia can be avoided and with it the supposed necessity of glasses in middle life. Early attention

  1. Negative refraction imaging of solid acoustic waves by two-dimensional three-component phononic crystal

    International Nuclear Information System (INIS)

    Li Jing; Liu Zhengyou; Qiu Chunyin

    2008-01-01

    By using of the multiple scattering methods, we study the negative refraction imaging effect of solid acoustic waves by two-dimensional three-component phononic crystals composed of coated solid inclusions placed in solid matrix. We show that localized resonance mechanism brings on a group of flat single-mode bands in low-frequency region, which provides two equivalent frequency surfaces (EFS) close to circular. The two constant frequency surfaces correspond to two Bloch modes, a right-handed and a left-handed, whose leading mode are respectively transverse (T) and longitudinal (L) modes. The negative refraction behaviors of the two kinds of modes have been demonstrated by simulation of a Gaussian beam through a finite system. High-quality far-field imaging by a planar lens for transverse or longitudinal waves has been realized separately. This three-component phononic crystal may thus serve as a mode selector in negative refraction imaging of solid acoustic waves

  2. Comparison of the visual and intraocular optical performance of a refractive multifocal IOL with rotational asymmetry and an apodized diffractive multifocal IOL.

    Science.gov (United States)

    Alió, Jorge L; Plaza-Puche, Ana B; Javaloy, Jaime; Ayala, María José

    2012-02-01

    To compare the visual outcomes and intraocular optical quality observed postoperatively in patients implanted with a rotationally asymmetric multifocal intraocular lens (IOL) and an apodized diffractive multifocal IOL. Seventy-four consecutive eyes of 40 cataract patients (age range: 36 to 79 years) were divided into two groups: zonal refractive group, 39 eyes implanted with a rotationally asymmetric multifocal IOL (Lentis Mplus LS-312 IOL, Oculentis GmbH); and diffractive group, 35 eyes implanted with an apodized diffractive multifocal IOL (ReSTOR SN6AD3, Alcon Laboratories Inc). Distance and near visual acuity outcomes, contrast sensitivity, intraocular optical quality, and defocus curves were evaluated during 3-month follow-up. Calculation of the intraocular aberrations was performed by subtracting corneal aberrations from total ocular aberrations. Uncorrected near visual acuity and distance-corrected near visual acuity were better in the diffractive group than in the zonal refractive group (P=.01), whereas intermediate visual acuity (defocus +1.00 and +1.50 diopters) was better in the zonal refractive group. Photopic contrast sensitivity was significantly better in the zonal refractive group (P=.04). Wavefront aberrations (total, higher order, tilt, primary coma) were significantly higher in the zonal refractive group than in the diffractive group (P=.02). Both multifocal IOLs are able to successfully restore visual function after cataract surgery. The zonal refractive multifocal IOL provides better results in contrast sensitivity and intermediate vision, whereas the diffractive multifocal IOL provides better near vision at a closer distance. Copyright 2012, SLACK Incorporated.

  3. Parsimonious wave-equation travel-time inversion for refraction waves

    KAUST Repository

    Fu, Lei

    2017-02-14

    We present a parsimonious wave-equation travel-time inversion technique for refraction waves. A dense virtual refraction dataset can be generated from just two reciprocal shot gathers for the sources at the endpoints of the survey line, with N geophones evenly deployed along the line. These two reciprocal shots contain approximately 2N refraction travel times, which can be spawned into O(N2) refraction travel times by an interferometric transformation. Then, these virtual refraction travel times are used with a source wavelet to create N virtual refraction shot gathers, which are the input data for wave-equation travel-time inversion. Numerical results show that the parsimonious wave-equation travel-time tomogram has about the same accuracy as the tomogram computed by standard wave-equation travel-time inversion. The most significant benefit is that a reciprocal survey is far less time consuming than the standard refraction survey where a source is excited at each geophone location.

  4. Microstructured optical fiber refractive index sensor

    DEFF Research Database (Denmark)

    Town, Graham E.; McCosker, Ravi; Yuan, Scott Wu

    2010-01-01

    We describe a dual-core microstructured optical fiber designed for refractive index sensing of fluids. We show that by using the exponential dependence of intercore coupling on analyte refractive index, both large range and high sensitivity can be achieved in the one device. We also show...

  5. On-Error Training (Book Excerpt).

    Science.gov (United States)

    Fukuda, Ryuji

    1985-01-01

    This excerpt from "Managerial Engineering: Techniques for Improving Quality and Productivity in the Workplace" describes the development, objectives, and use of On-Error Training (OET), a method which trains workers to learn from their errors. Also described is New Joharry's Window, a performance-error data analysis technique used in…

  6. Refraction in the lower troposphere: Higher order image distortion effects due to refractive profile curvature

    Science.gov (United States)

    Short, Daniel J.

    There are many applications that rely on the propagation of light through the atmosphere - all of which are subject to atmospheric conditions. While there are obvious processes such as scattering due to particulates like clouds and dust that affect the received intensity of the radiation, the clear atmosphere can also cause significant effects. Refraction is a clear air effect that can cause a variety of phenomena such as apparent relocation, stretching and compression of objects when viewed through the atmosphere. Recently, there has been significant interest in studying the refractive effects for low angle paths within the troposphere, and in particular, near-horizontal paths in the Earth's boundary layer, which is adjacent to the ground. Refractive effects in this case become problematic for many terrestrial optical applications. For example, the pointing of a free space optical communication or a remote sensing system can suffer wandering effects, high-resolution imagery can present distorted and/or dislocated targets, optical tracking of targets can be inaccurate, and optical geodetic surveying accuracy is also very sensitive to the effects of refraction. The work in this dissertation was inspired by data from a time-lapse camera system that collects images of distant targets over a near-horizontal path along the ground. This system was used previously to study apparent diurnal image displacement and this dissertation extends that work by exploring the higher order effects that result from curvature in the vertical refractive index profile of the atmosphere. There are surprisingly few experiments involving atmospheric refractive effects that carefully correlate field data to analytical expressions and other factors such as meteorological data. In working with the time-lapse data, which is comprised of sequences of hundreds or thousands of images collected over durations of weeks or months, it is important to develop straightforward analysis techniques that can

  7. Radiation-induced refraction artifacts in the optical CT readout of polymer gel dosimeters

    International Nuclear Information System (INIS)

    Campbell, Warren G.; Jirasek, Andrew; Wells, Derek M.

    2014-01-01

    Purpose: The objective of this work is to demonstrate imaging artifacts that can occur during the optical computed tomography (CT) scanning of polymer gel dosimeters due to radiation-induced refractive index (RI) changes in polyacrylamide gels. Methods: A 1 L cylindrical polyacrylamide gel dosimeter was irradiated with 3 × 3 cm 2 square beams of 6 MV photons. A prototype fan-beam optical CT scanner was used to image the dosimeter. Investigative optical CT scans were performed to examine two types of rayline bending: (i) bending within the plane of the fan-beam and (ii) bending out the plane of the fan-beam. To address structured errors, an iterative Savitzky–Golay (ISG) filtering routine was designed to filter 2D projections in sinogram space. For comparison, 2D projections were alternatively filtered using an adaptive-mean (AM) filter. Results: In-plane rayline bending was most notably observed in optical CT projections where rays of the fan-beam confronted a sustained dose gradient that was perpendicular to their trajectory but within the fan-beam plane. These errors caused distinct streaking artifacts in image reconstructions due to the refraction of higher intensity rays toward more opaque regions of the dosimeter. Out-of-plane rayline bending was observed in slices of the dosimeter that featured dose gradients perpendicular to the plane of the fan-beam. These errors caused widespread, severe overestimations of dose in image reconstructions due to the higher-than-actual opacity that is perceived by the scanner when light is bent off of the detector array. The ISG filtering routine outperformed AM filtering for both in-plane and out-of-plane rayline errors caused by radiation-induced RI changes. For in-plane rayline errors, streaks in an irradiated region (>7 Gy) were as high as 49% for unfiltered data, 14% for AM, and 6% for ISG. For out-of-plane rayline errors, overestimations of dose in a low-dose region (∼50 cGy) were as high as 13 Gy for unfiltered

  8. Refractive index depth profile in PMMA due to proton irradiation

    International Nuclear Information System (INIS)

    Szilasi, S.Z.; Rajta, I.; Budai, J.; Toth, Z.; Petrik, P.; Baradacs, E.

    2006-01-01

    Complete text of publication follows. During Proton Beam Writing the beam damage causes chain scissioning in the polymer resist material (e.g. PMMA (Polymethyl methacrylate)), producing smaller molecular weight chains. Hydrogen implantation also takes place at the end of range. Compaction of the sample has been observed too, which means that the sample density becomes higher at the places where proton irradiation occurred. Furthermore, P-beam Writing has been successfully used to create buried channel waveguides in PMMA [1], since proton irradiation increases the refractive index. There are two ways of fabricating waveguides using P-beam Writing, one of them applies direct micromachining of the high refractive index core followed by the coating of a lower refractive index cladding layer. In this application the refractive indices of the substrate, the core and the cladding have to be known, which should be homogeneous within the whole structure. The other method allows producing buried waveguides. In this case proton beam writing is used to modify the refractive index along the ion path in the sample, where most of the ion energy is deposited near the end of range also known as the Bragg peak. For polymers 10 -3 refractive index change has been reported, which is usually sufficient for forming waveguides. Those measurements of the refractive index change have been performed by the refracted near field technique. In this work we used ellipsometry, in order to measure the optical parameters of the P-beam treated sample near the surface, and along the Bragg curve. Ellipsometry measures the change in the polarization state of light occurring during reflection. This change is related to the quality of the reflecting surface (i.e. the physical structure, layer thicknesses, optical constants, surface roughness, etc.). >From these measurements the refractive index and the extinction coefficient can be determined rather accurately, which makes ellipsometry a powerful tool

  9. Prevalence and associations of anisometropia with spherical ametropia, cylindrical power, age, and sex in refractive surgery candidates.

    Science.gov (United States)

    Linke, Stephan J; Richard, Gisbert; Katz, Toam

    2011-09-29

    To analyze the prevalence and associations of anisometropia with spherical ametropia, astigmatism, age, and sex in a refractive surgery population. Medical records of 27,070 eyes of 13,535 refractive surgery candidates were reviewed. Anisometropia, defined as the absolute difference in mean spherical equivalent powers between right and left eyes, was analyzed for subjective (A(subj)) and cycloplegic refraction (A(cycl)). Correlations between anisometropia (>1 diopter) and spherical ametropia, cylindrical power, age, and sex, were analyzed using χ² and nonparametric Kruskal-Wallis or Mann-Whitney tests and binomial logistic regression analyses. Power vector analysis was applied for further analysis of cylindrical power. Prevalence of A(subj) was 18.5% and of A(cycl) was 19.3%. In hyperopes, logistic regression analysis revealed that only spherical refractive error (odds ratio [OR], 0.72) and age (OR, 0.97) were independently associated with anisometropia. A(subj) decreased with increasing spherical ametropia and advancing age. Cylindrical power and sex did not significantly affect A(subj). In myopes all explanatory variables (spherical power OR, 0.93; cylindrical power OR, 0.75; age OR, 1.02; sex OR, 0.8) were independently associated with anisometropia. Cylindrical power was most strongly associated with anisometropia. Advancing age and increasing spherical/cylindrical power correlated positively with increasing anisometropia in myopic subjects. Female sex was more closely associated with anisometropia. This large-scale retrospective analysis confirmed an independent association between anisometropia and both spherical ametropia and age in refractive surgery candidates. Notably, an inverse relationship between these parameters in hyperopes was observed. Cylindrical power and female sex were independently associated with anisometropia in myopes.

  10. The refractive index of human hemoglobin in the visible range

    International Nuclear Information System (INIS)

    Zhernovaya, O; Tuchin, V; Sydoruk, O; Douplik, A

    2011-01-01

    Because the refractive index of hemoglobin in the visible range is sensitive to the hemoglobin concentration, optical investigations of hemoglobin are important for medical diagnostics and treatment. Direct measurements of the refractive index are, however, challenging; few such measurements have previously been reported, especially in a wide wavelength range. We directly measured the refractive index of human deoxygenated and oxygenated hemoglobin for nine wavelengths between 400 and 700 nm for the hemoglobin concentrations up to 140 g l -1 . This paper analyzes the results and suggests a set of model functions to calculate the refractive index depending on the concentration. At all wavelengths, the measured values of the refractive index depended on the concentration linearly. Analyzing the slope of the lines, we determined the specific refraction increments, derived a set of model functions for the refractive index depending on the concentration, and compared our results with those available in the literature. Based on the model functions, we further calculated the refractive index at the physiological concentration within the erythrocytes of 320 g l -1 . The results can be used to calculate the refractive index in the visible range for arbitrary concentrations provided that the refractive indices depend on the concentration linearly.

  11. Negative Refraction Angular Characterization in One-Dimensional Photonic Crystals

    OpenAIRE

    Lugo, Jesus Eduardo; Doti, Rafael; Faubert, Jocelyn

    2011-01-01

    Background Photonic crystals are artificial structures that have periodic dielectric components with different refractive indices. Under certain conditions, they abnormally refract the light, a phenomenon called negative refraction. Here we experimentally characterize negative refraction in a one dimensional photonic crystal structure; near the low frequency edge of the fourth photonic bandgap. We compare the experimental results with current theory and a theory based on the group velocity de...

  12. Objective quality of vision in presbyopic and non-presbyopic patients after pseudoaccommodative advanced surface ablation.

    Science.gov (United States)

    Cantú, Roberto; Rosales, Marco A; Tepichín, Eduardo; Curioca, Andrée; Montes, Víctor; Ramirez-Zavaleta, J Gustavo

    2005-01-01

    To analyze the objective quality of vision at 6 months postoperatively after pseudoaccommodative (presbyopic) advanced surface ablation (PASA). The study comprised 62 eyes of 35 patients with 6-month follow-up that underwent primary or secondary treatments using PASA. Pre- and postoperative results of distance and near uncorrected visual acuity (UCVA), spherical aberration (coefficient of the Z12 Zernike polynomial), and the asphericity (Q) index were reviewed. The corresponding wavefront maps (total, low, and high order aberrations) and the corresponding point spread function and modulation transfer function (MTF) were also calculated. Our results show that PASA improves distance and near mean UCVA, increases negative spherical aberration and negative asphericity index, and improves the corresponding MTF. Pseudoaccommodative advanced surface ablation is a promising approach for the surgical correction of presbyopia with distance refractive error (myopia and hyperopia with or without astigmatism). This PASA technique could theoretically be used in non-presbyopic patients with refractive error or post cataract patients with monofocal intraocular lenses. The increase in negative spherical aberration and asphericity/eccentricity index seems to increase the depth of focus of the eye, improving the near vision and compensating the age-related lens changes. Rather than creating a multifocal cornea, PASA appears to create an improved aspheric (prolate) ablation profile.

  13. Experimental Determination of Refractive Index of Gas Hydrates

    DEFF Research Database (Denmark)

    Bylov, Martin; Rasmussen, Peter

    1997-01-01

    . For methane hydrate (structure I) the refractive index was found to be 1.346 and for natural gas hydrate (structure II) it was found to be 1.350. The measurements further suggest that the gas hydrate growth rate increases if the water has formed hydrates before. The induction time, on the other hand, seems......The refractive indexes of methane hydrate and natural gas hydrate have been experimentally determined. The refractive indexes were determined in an indirect manner making use of the fact that two non-absorbing materials will have the same refractive index if they cannot be distinguished visually...

  14. Characterizing conical refraction optical tweezers

    Science.gov (United States)

    McDonald, C.; McDougall, C.; Rafailov, E.; McGloin, D.

    2014-12-01

    Conical refraction occurs when a beam of light travels through an appropriately cut biaxial crystal. By focussing the conically refracted beam through a high numerical aperture microscope objective, conical refraction optical tweezers can be created, allowing for particle manipulation in both Raman spots and in the Lloyd/Poggendorff rings. We present a thorough quantification of the trapping properties of such a beam, focussing on the trap stiffness and how this varies with trap power and trapped particle location. We show that the lower Raman spot can be thought of as a single-beam optical gradient force trap, while radiation pressure dominates in the upper Raman spot, leading to optical levitation rather than trapping. Particles in the Lloyd/Poggendorff rings experience a lower trap stiffness than particles in the lower Raman spot but benefit from rotational control.

  15. Investigation into the limitations of straightness interferometers using a multisensor-based error separation method

    Science.gov (United States)

    Weichert, Christoph; Köchert, Paul; Schötka, Eugen; Flügge, Jens; Manske, Eberhard

    2018-06-01

    The uncertainty of a straightness interferometer is independent of the component used to introduce the divergence angle between the two probing beams, and is limited by three main error sources, which are linked to each other: their resolution, the influence of refractive index gradients and the topography of the straightness reflector. To identify the configuration with minimal uncertainties under laboratory conditions, a fully fibre-coupled heterodyne interferometer was successively equipped with three different wedge prisms, resulting in three different divergence angles (4°, 8° and 20°). To separate the error sources an independent reference with a smaller reproducibility is needed. Therefore, the straightness measurement capability of the Nanometer Comparator, based on a multisensor error separation method, was improved to provide measurements with a reproducibility of 0.2 nm. The comparison results revealed that the influence of the refractive index gradients of air did not increase with interspaces between the probing beams of more than 11.3 mm. Therefore, over a movement range of 220 mm, the lowest uncertainty was achieved with the largest divergence angle. The dominant uncertainty contribution arose from the mirror topography, which was additionally determined with a Fizeau interferometer. The measured topography agreed within  ±1.3 nm with the systematic deviations revealed in the straightness comparison, resulting in an uncertainty contribution of 2.6 nm for the straightness interferometer.

  16. Initial resident refractive surgical experience: outcomes of PRK and LASIK for myopia.

    Science.gov (United States)

    Wagoner, Michael D; Wickard, Joseph C; Wandling, George R; Milder, Lisa C; Rauen, Matthew P; Kitzmann, Anna S; Sutphin, John E; Goins, Kenneth M

    2011-03-01

    To evaluate and compare the outcome of initial resident surgical experience with photorefractive keratectomy (PRK) and LASIK. Retrospective review of all cases performed with the VISX Star S4 platform (Abbott Medical Optics) between July 1, 2003 and June 30, 2007. Inclusion criteria were spherical equivalent of -0.50 to -10.00 diopters (D), refractive astigmatic error of ≤3.00 D, intention to provide full distance correction, and minimum 3-month postoperative follow-up after initial ablation or retreatment (if performed). A total of 153 cases performed by 20 different residents met the inclusion criteria; 38 eyes underwent PRK and 115 eyes had LASIK. After initial treatment, mean Snellen uncorrected distance visual acuity (UDVA) after PRK was 20/17.3 and after LASIK was 20/19.5. Photorefractive keratectomy was associated with a significantly better approximation between preoperative corrected distance visual acuity (CDVA) and postoperative UDVA (ΔlogMAR 0.009 vs 0.091; P=.004) and a greater percentage of eyes that achieved UDVA of 20/20 or better (94.7% vs 78.3%; P=.02) or 20/30 or better (100% vs 87.8%; P=.02). There was a higher prevalence of retreatment in eyes that underwent LASIK (7.0% vs 0%; P=.20). One (0.9%) eye lost 2 lines of CDVA after LASIK. Supervised refractive surgery residents can achieve excellent visual outcomes in patients operated during their initial refractive experience. Photorefractive keratectomy was associated with better visual outcome than LASIK. Copyright 2011, SLACK Incorporated.

  17. Macroeconomic landscape of refractive surgery in the United States.

    Science.gov (United States)

    Corcoran, Kevin J

    2015-07-01

    This review examines the economic history of refractive surgery and the decline of laser-assisted in-situ keratomileusis (LASIK) in the USA, and the emergence of refractive cataract surgery as an area of growth. Since it peaked in 2007 at 1.4 million procedures per year, LASIK has declined 50% in the USA, whereas refractive cataract surgery, including presbyopia-correcting intraocular lenses (IOLs), astigmatism-correcting IOLs, and femtosecond laser-assisted cataract surgery, has grown to 350 000 procedures per year, beginning in 2003. Patients are price-sensitive and responsive to publicity (good or bad) about refractive surgery and refractive cataract surgery. LASIK's decline has been partially offset by the emergence of refractive cataract surgery. About 11% of all cataract surgery in the USA involves presbyopia-correcting IOLs, astigmatism-correcting IOLs, or a femtosecond laser. From the surgeon's perspective, there are high barriers to entry into the marketplace for refractive surgery and refractive cataract surgery due to the high capital cost of excimer and femtosecond lasers, the high skill level required to deliver spectacular results to demanding patients who pay out of pocket, and the necessity to perform a high volume of surgeries to satisfy both of these requirements. Probably, less than 7% of US cataract surgeons can readily meet all of these requirements.

  18. Simultaneous determination of ordinary and extraordinary refractive index dispersions of nematic liquid crystals in the visible and near-infrared regions from an interference spectrum

    Science.gov (United States)

    Ozaki, Ryotaro; Nishi, Koji; Kan, Takayuki; Kadowaki, Kazunori

    2016-10-01

    An improved interference method is proposed to determine ordinary and extraordinary refractive index dispersions of nematic liquid crystals (LCs). In this method, an LC cell coated with a thin metal layer is used as a Fabry-Perot interferometer, which shows us a sharp transmission fringe. To ensure high reliability, the wavelength dispersion of the refractive index of the metal is taken into account in fitting calculation. In spite of measuring ordinary and extraordinary components, the LC cell, polarizers, and other equipment are not rotated during the experiment. The index evaluation from a single spectrum avoids errors depending on the measurement position owing to non-uniformities of molecular orientation and cell thickness because we can obtain the two indices at exactly the same position. This system can adapt to a wide frequency range and does not require any specific wavelength light source or laser. We demonstrate the determination of ordinary and extraordinary refractive index dispersions of a nematic liquid crystal in the visible and near-infrared regions. Furthermore, we quantitatively reproduce the measured spectrum by calculation using the measured refractive indices.

  19. Computational imaging using lightweight diffractive-refractive optics

    KAUST Repository

    Peng, Yifan

    2015-11-23

    Diffractive optical elements (DOE) show great promise for imaging optics that are thinner and more lightweight than conventional refractive lenses while preserving their light efficiency. Unfortunately, severe spectral dispersion currently limits the use of DOEs in consumer-level lens design. In this article, we jointly design lightweight diffractive-refractive optics and post-processing algorithms to enable imaging under white light illumination. Using the Fresnel lens as a general platform, we show three phase-plate designs, including a super-thin stacked plate design, a diffractive-refractive-hybrid lens, and a phase coded-aperture lens. Combined with cross-channel deconvolution algorithm, both spherical and chromatic aberrations are corrected. Experimental results indicate that using our computational imaging approach, diffractive-refractive optics is an alternative candidate to build light efficient and thin optics for white light imaging.

  20. Computational imaging using lightweight diffractive-refractive optics

    KAUST Repository

    Peng, Yifan; Fu, Qiang; Amata, Hadi; Su, Shuochen; Heide, Felix; Heidrich, Wolfgang

    2015-01-01

    Diffractive optical elements (DOE) show great promise for imaging optics that are thinner and more lightweight than conventional refractive lenses while preserving their light efficiency. Unfortunately, severe spectral dispersion currently limits the use of DOEs in consumer-level lens design. In this article, we jointly design lightweight diffractive-refractive optics and post-processing algorithms to enable imaging under white light illumination. Using the Fresnel lens as a general platform, we show three phase-plate designs, including a super-thin stacked plate design, a diffractive-refractive-hybrid lens, and a phase coded-aperture lens. Combined with cross-channel deconvolution algorithm, both spherical and chromatic aberrations are corrected. Experimental results indicate that using our computational imaging approach, diffractive-refractive optics is an alternative candidate to build light efficient and thin optics for white light imaging.

  1. Alignment and focusing tolerance influences on optical performance

    International Nuclear Information System (INIS)

    Cross, E.W.

    1982-01-01

    Alignment errors among components of an optical system may substantially degrade the image quality. Focus errors also affect system performance. The potential for serious degradation of image quality is substantial and requires that the tolerances for these errors receive significant attention early in system design. The image quality and reconnaissance performance of an all-reflecting Cassegrain is compared to an all-refractive optical system under conditions of zero and anticipated real world misalignments

  2. Quasi-D-shaped optical fiber plasmonic refractive index sensor

    Science.gov (United States)

    An, Guowen; Li, Shuguang; Wang, Haiyang; Zhang, Xuenan; Yan, Xin

    2018-03-01

    A quasi-D-shaped photonic crystal fiber plasmonic sensor with a rectangular lattice is proposed by using Au as a plasmonic layer and graphene to enhance the sensing performance. By moving the core to the edge of the fiber, a shorter polishing depth is achieved, which makes the fiber proposed have a greater mechanical strength than other common D-shaped fibers. Benefiting from the natural advantage of the rectangular lattice, the dual sensing channels make the proposed sensor show a maximum wavelength interrogation sensitivity of 3877 nm/RIU with the dynamic refractive index range from 1.33 to 1.42 and a maximum amplitude sensitivity of 1236 RIU-1 with the analyte RI = 1.41 in the visible region. The corresponding resolutions are 2.58 × 10-5 and 8.1 × 10-6 with the methods of the wavelength interrogation method and amplitude- or phase-based method. These advantages make the proposed sensor a competitive candidate for biosensing in the field of refractive index detection, such as water quality analysis, clinical medicine detection, and pharmaceutical testing.

  3. Evidence for subwavelength imaging with positive refraction

    Energy Technology Data Exchange (ETDEWEB)

    Ma, Yun Gui [Temasek Laboratories, National University of Singapore, Singapore 119260 (Singapore); Sahebdivan, Sahar; Tyc, Tomas; Leonhardt, Ulf [School of Physics and Astronomy, University of St Andrews, North Haugh, St Andrews KY16 9SS (United Kingdom); Ong, C K, E-mail: ulf@st-andrews.ac.uk [Centre for Superconducting and Magnetic Materials, Department of Physics, National University of Singapore, Singapore 117542 (Singapore)

    2011-03-15

    The resolution of lenses is normally limited by the wave nature of light. Imaging with perfect resolution was believed to rely on negative refraction, but here we present experimental evidence for subwavelength imaging with positive refraction.

  4. Evidence for subwavelength imaging with positive refraction

    International Nuclear Information System (INIS)

    Ma, Yun Gui; Sahebdivan, Sahar; Tyc, Tomas; Leonhardt, Ulf; Ong, C K

    2011-01-01

    The resolution of lenses is normally limited by the wave nature of light. Imaging with perfect resolution was believed to rely on negative refraction, but here we present experimental evidence for subwavelength imaging with positive refraction.

  5. Low-to-high refractive index contrast transition (RICT) device for low loss polymer-based optical coupling

    Science.gov (United States)

    Calabretta, N.; Cooman, I. A.; Stabile, R.

    2018-04-01

    We propose for the first time a coupling device concept for passive low-loss optical coupling, which is compatible with the ‘generic’ indium phosphide (InP) multi-project-wafer manufacturing. A low-to-high vertical refractive index contrast transition InP waveguide is designed and tapered down to adiabatically couple light into a top polymer waveguide. The on-chip embedded polymer waveguide is engineered at the chip facets for offering refractive-index and spot-size-matching to silica fiber-arrays. Numerical analysis shows that coupling losses lower than 1.5 dB can be achieved for a TE-polarized light between the InP waveguide and the on-chip embedded polymer waveguide at 1550 nm wavelength. The performance is mainly limited by the difficulty to control single-mode operation. However, coupling losses lower than 1.9 dB can be achieved for a bandwidth as large as 200 nm. Moreover, the foreseen fabrication process steps are indicated, which are compatible with the ‘generic’ InP multi-project-wafer manufacturing. A fabrication error tolerance study is performed, indicating that fabrication errors occur only in 0.25 dB worst case excess losses, as long as high precision lithography is used. The obtained results are promising and may open the route to large port counts and cheap packaging of InP-based photonic integrated chips.

  6. Video Error Correction Using Steganography

    Science.gov (United States)

    Robie, David L.; Mersereau, Russell M.

    2002-12-01

    The transmission of any data is always subject to corruption due to errors, but video transmission, because of its real time nature must deal with these errors without retransmission of the corrupted data. The error can be handled using forward error correction in the encoder or error concealment techniques in the decoder. This MPEG-2 compliant codec uses data hiding to transmit error correction information and several error concealment techniques in the decoder. The decoder resynchronizes more quickly with fewer errors than traditional resynchronization techniques. It also allows for perfect recovery of differentially encoded DCT-DC components and motion vectors. This provides for a much higher quality picture in an error-prone environment while creating an almost imperceptible degradation of the picture in an error-free environment.

  7. Seismic refraction survey of the ANS preferred site

    Energy Technology Data Exchange (ETDEWEB)

    Davis, R.K. (Automated Sciences Group, Inc., Oak Ridge, TN (United States)); Hopkins, R.A. (Marrich, Inc., Knoxville, TN (United States)); Doll, W.E. (Oak Ridge National Lab., TN (United States))

    1992-02-01

    Between September 19, 1991 and October 8, 1991 personnel from Martin Marietta Energy Systems, Inc. (Energy Systems), Automated Sciences Group, Inc., and Marrich, Inc. performed a seismic refraction survey at the Advanced Neutron Source (ANS) preferred site. The purpose of this survey was to provide estimates of top-of-rock topography, based on seismic velocities, and to delineate variations in rock and soil velocities. Forty-four seismic refraction spreads were shot to determine top-of-rock depths at 42 locations. Nine of the seismic spreads were shot with long offsets to provide 216 top-of-rock depths for 4 seismic refraction profiles. The refraction spread locations were based on the grid for the ANS Phase I drilling program. Interpretation of the seismic refraction data supports the assumption that the top-of-rock surface generally follows the local topography. The shallow top-of-rock interface interpreted from the seismic refraction data is also supported by limited drill information at the site. Some zones of anomalous data are present that could be the result of locally variable weathering, a localized variation in shale content, or depth to top-of-rock greater than the site norm.

  8. On the effective refractive index of blood

    Science.gov (United States)

    Nahmad-Rohen, Alexander; Contreras-Tello, Humberto; Morales-Luna, Gesuri; García-Valenzuela, Augusto

    2016-01-01

    We calculated the real and imaginary parts of the effective refractive index {n}{eff} of blood as functions of wavelength from 400 to 800 nm; we employed van de Hulst’s theory, together with the anomalous diffraction approximation, for the calculation. We modelled blood as a mixture of plasma and erythrocytes. Our results indicate that erythrocyte orientation has a strong effect on {n}{eff}, making blood an optically anisotropic medium except when the erythrocytes are randomly oriented. In the case in which their symmetry axis is perpendicular to the wave vector, {n}{eff} equals the refractive index of plasma at certain wavelengths. Furthermore, the erythrocytes’ shape affects their contribution to {n}{eff} in an important way, implying that studies on the effective refractive index of blood should avoid approximating them as spheres or spheroids. Finally, the effective refractive index of blood predicted by van de Hulst’s theory is different from what would be obtained by averaging the refractive indices of its constituents weighted by volume; such a volume-weighted average is appropriate only for haemolysed blood. We then measured the real part of the refractive index of various blood solutions using two different experimental setups. One of the most important results of our expriment is that {n}{eff} is measurable to a good degree of precision even for undiluted blood, although not all measuring apparatuses are appropriate. The experimental data is self-consistent and in reasonable agreement with our theoretical calculations.

  9. Light rays in gravitating, refractive media

    International Nuclear Information System (INIS)

    Noonan, T.W.

    1982-01-01

    The field-to-particle method of H. P. Robertson is applied to the general-relativistic Maxwell equations in order to obtain the general-relativistic equation of motion for a photon in a refractive medium. For the special case of an uncharged, refractive, spherically symmetric mass, the exact first-order differential equation for the light-ray path is given

  10. Preventable visual impairment in children 
with nonprofound intellectual disability.

    Science.gov (United States)

    Aslan, Lokman; Aslankurt, Murat; Aksoy, Adnan; Altun, Hatice

    2013-01-01

    To assess the preventable visual impairment in children with nonprofound intellectual disability (ID). 
 A total of 215 children with IDs (90 Down syndrome [DS], 125 nonprofound ID) and 116 age- and sex-matched healthy subjects were enrolled in this study. All participants underwent ophthalmologic examinations including cycloplegic refraction measurements, ocular movement evaluation, screening for strabismus (Hirschberg, Krimsky, or prism cover test), slit-lamp biomicroscopy, funduscopy, and intraocular pressure measurements. All data were recorded for statistical analysis.
 Ocular findings in decreasing prevalence were as follows: refractive errors 55 (61.1%), strabismus 30 (33.2%), cataract 7 (7.8%), and nystagmus 7 (7.8%) in children with DS; refractive errors 57 (45.6%), strabismus 19 (15.2%), cataract 7 (6.4%), nystagmus 5 (4%), and glaucoma 1 (0.8%) in children with other ID; and refractive errors 13 (11.2%) and strabismus 4 (3.5%) in controls. Cataracts, glaucoma, and nystagmus were not observed in the control group. The most common ophthalmic findings in children with DS compared with other ID and controls were with hyperopia (pvisual impairments, refractive errors, strabismus, and cataracts. The prevalence of strabismus and refractive errors was more frequent in children with DS. The importance of further health screenings including ophthalmic examinations should be utilized to implement appropriate care management and improve quality of life.

  11. Evidence for subwavelength imaging with positive refraction

    OpenAIRE

    Ma, Yun Gui; Sahebdivan, Sahar; Ong, C. K.; Tyc, Tomas; Leonhardt, Ulf

    2011-01-01

    The resolution of lenses is normally limited by the wave nature of light. Imaging with perfect resolution was believed to rely on negative refraction, but here we present experimental evidence for subwavelength imaging with positive refraction. Publisher PDF Peer reviewed

  12. Assimilation of GPS Refractivity from FORMOSAT-3/COSMIC Using a Nonlocal Operator with WRF 3DVAR and Its Impact on the Prediction of a Typhoon Event

    Directory of Open Access Journals (Sweden)

    Shu-Ya Chen

    2009-01-01

    Full Text Available A nonlocal observation operator has been developed to assimilate GPS radio occultation (RO refractivity with WRF 3DVAR. For simplicity, in the past GPS RO refractivity was often assimilated using a local observation operator with the assumption that the GPS RO observation was representative of amodel local point. Such an operator did not take into account the effects of horizontal inhomogeneity on the derived GPS RO refractivity. In order to more accurately model the observables, Sokolovskiy et al. (2005a developed a nonlocal observation operator, which would take into account the effects of horizontal inhomogeneity on GPS RO measurements. This nonlocal observation operator calculates the integrated amount of the model refractivity along the ray paths centered at the perigee points. For comparative purposes, the nonlocal observation operator can be simplified by limiting the length of integration near the RO point. This is called the "local operator variant", which is equivalent to the original local operator except that the original one is performed with fixed tangent points at observation levels. For computational efficiency, assimilation using both the nonlocal operator and local operator variant now is performed with smear tangent points at the mean height of each model vertical level. In this study, the statistics of observation errors using both local and nonlocal operators were estimated based on WRF simulations. The observation errors produced by the nonlocal operator are about two times smaller than those generated by the local operator and in agreement with Sokolovskiy et al. (2005b.

  13. Perfect imaging without negative refraction

    OpenAIRE

    Leonhardt, Ulf

    2009-01-01

    Perfect imaging has been believed to rely on negative refraction, but here we show that an ordinary positively-refracting optical medium may form perfect images as well. In particular, we establish a mathematical proof that Maxwell's fish eye in two-dimensional integrated optics makes a perfect instrument with a resolution not limited by the wavelength of light. We also show how to modify the fish eye such that perfect imaging devices can be made in practice. Our method of perfect focusing ma...

  14. Video Error Correction Using Steganography

    Directory of Open Access Journals (Sweden)

    Robie David L

    2002-01-01

    Full Text Available The transmission of any data is always subject to corruption due to errors, but video transmission, because of its real time nature must deal with these errors without retransmission of the corrupted data. The error can be handled using forward error correction in the encoder or error concealment techniques in the decoder. This MPEG-2 compliant codec uses data hiding to transmit error correction information and several error concealment techniques in the decoder. The decoder resynchronizes more quickly with fewer errors than traditional resynchronization techniques. It also allows for perfect recovery of differentially encoded DCT-DC components and motion vectors. This provides for a much higher quality picture in an error-prone environment while creating an almost imperceptible degradation of the picture in an error-free environment.

  15. Application of refractometry to quality assurance monitoring of parenteral nutrition solutions.

    Science.gov (United States)

    Chang, Wei-Kuo; Chao, You-Chen; Yeh, Ming-Kung

    2008-01-01

    Parenteral nutrition (PN) solution contains various concentrations of dextrose, amino acids, lipids, vitamins, electrolytes, and trace elements. Incorrect preparation of PN solution could lead to patient death. In this study we used the refractive index as a quality assurance tool to monitor the preparation of PN solution. Refractive indices of single nutrient components and PN solutions consisting of various concentrations of dextrose, amino acids, electrolytes, and lipids were measured. A mathematical equation and its linear plot were generated then used to predict the refractive index of the PN solution. The best-fit refractive index for PN solution (i.e., the predicted refractive index)=0.9798x(% dextrose)+1.2889x(% amino acids)+1.1017x(% lipids)+0.9440x(% sum of the electrolytes)+0.5367 (r2=0.99). This equation was validated by comparing the measured refractive indices of 500 clinical PN solutions to their predicted refractive indices. We found that 2 of the 500 prepared samples (0.4%) had less than the predicted refractive index (<95%). Refractive index can be used as a reliable quality assurance tool for monitoring PN preparation. Such information can be obtained at the bedside and used to confirm the accuracy of the PN solution composition.

  16. Dispersion characteristics of negative refraction sonic crystals

    International Nuclear Information System (INIS)

    Wu, L.-Y.; Chen, L.-W.; Wang, R.C.-C.

    2008-01-01

    Dispersion characteristics of negative refraction sonic crystals are investigated. The plane wave expansion method is used to calculate the equifrequency surface; the dependences of refractive direction on frequencies and incident angles for triangular lattices are shown. There exist the positive and negative refractive waves which include k.V g ≥0 and k.V g ≤0 in the second band for the triangular system. We also use the finite element method to demonstrate that the relative intensity of the transmitted acoustic waves is dependent on incident frequencies and angles. The positions of the partial band gaps obtained by the plane wave expansion method are in good agreement with those obtained by the finite element method. The sonic crystals with negative effective index are shown to have higher transmission intensities. By using the negative refraction behavior, we can design a sonic crystal plane lens to focus a sonic wave

  17. Refractive index inhomogeneity within an aerogel block

    International Nuclear Information System (INIS)

    Bellunato, T.; Calvi, M.; Da Silva Costa, C.F.; Matteuzzi, C.; Musy, M.; Perego, D.L.

    2006-01-01

    Evaluating local inhomogeneities of the refractive index inside aerogel blocks to be used as Cherenkov radiator is important for a high energy physics experiment where angular resolution is crucial. Two approaches are described and compared. The first one is based on the bending of a laser beam induced by refractive index gradients along directions normal to the unperturbed optical path. The second method exploits the Cherenkov effect itself by shooting an ultra-relativistic collimated electron beam through different points of the aerogel surface. Local refractive index variations result in sizable differences in the Cherenkov photons distribution

  18. Cryogenic refractive index of Heraeus homosil glass

    Science.gov (United States)

    Miller, Kevin H.; Quijada, Manuel A.; Leviton, Douglas B.

    2017-08-01

    This paper reports measurements of the refractive index of Homosil (Heraeus) over the wavelength range of 0.34—3.16 μm and temperature range of 120—335 K. These measurements were performed by using the Cryogenic High Accuracy Refraction Measuring System (CHARMS) facility at the NASA's Goddard Space Flight Center. These measurements were in support of an integrated Structural-Thermal-Optical-Performance (STOP) model that was developed for a fieldwidened Michelson interferometer that is being built and tested for the High Spectral Resolution Lidar (HSRL) project at the NASA Langley Research Center (LaRC). The cryogenic refractive index measurements were required in order to account for the highly sensitive performance of the HSRL instrument to changes in refractive index with temperature, temperature gradients, thermal expansion, and deformation due to mounting stresses. A dense coverage of the absolute refractive index over the aforementioned wavelength and temperature ranges was used to determine the thermo-optic coefficient (dn/dT) and dispersion relation (dn/dλ) as a function of wavelength and temperature. Our measurements of Homosil will be compared with measurements of other glasses from the fused silica family studied in CHARMS as well as measurements reported elsewhere in the literature.

  19. Long-range surface plasmon resonance sensor with liquid micro-channels to maintain the symmetry condition of the refractive index

    International Nuclear Information System (INIS)

    Kan, Tetsuo; Kojo, Hiroyuki; Iwase, Eiji; Matsumoto, Kiyoshi; Shimoyama, Isao

    2010-01-01

    We propose a method to maintain the symmetry of the refractive index with respect to an Au film, in which the refractive indices are the same near both surfaces of the Au film, for LRSPR (long-range surface plasmon resonance) sensors. Maintenance of the symmetry is necessary for exciting the LRSPR mode. However, because the buffer layer under the Au film is usually made of a solid dielectric material with a constant refractive index, the quality of the measurement is reduced when the refractive index of the analyte used is dramatically different from that of the buffer layer. To solve this problem, the proposed sensor is equipped with liquid channels under the Au film. The Au film used in this study was supported by a thin (100 nm) polymer film forming parallel, one-dimensional liquid channels with a 29 µm pitch. Because the analyte solution flows in the channels, both surfaces of the Au film face the same analyte. Thus, this configuration automatically satisfies the symmetry condition for analytes with a wide range of refractive indices. We examined the validity of the sensor and compared it to that of a conventional sensor by measuring the LRSPR for five analyte solutions with different refractive indices. LRSPR dips were clearly observed for all of the analytes tested. The dip of the conventional LRSPR sensor became shallow when the refractive index increased, with the final dip depth being 65% of the initial dip depth for a refractive index of 1.358. In contrast, the dip depth of the proposed LRSPR sensor remained constant over the entire measured refractive index range of 1.331 to 1.358. These results indicate that the proposed sensor maintains the symmetry condition and confirm that the proposed method is effective for highly sensitive LRSPR measurements for a wide variety of analyte species

  20. Plasmon-negative refraction at the heterointerface of graphene sheet arrays.

    Science.gov (United States)

    Huang, He; Wang, Bing; Long, Hua; Wang, Kai; Lu, Peixiang

    2014-10-15

    We demonstrate negative refraction of surface plasmon polaritons (SPPs) at the heterointerface of two monolayer graphene sheet arrays (MGSAs) with different periods. The refraction angle is specifically related to the period ratio of the two MGSAs. By varying the incident Bloch momentum, the SPPs might be refracted in the direction normal to the heterointerface. Moreover, both positive and negative refraction could appear simultaneously. Because of the linear diffraction relation, the incident and refracted SPP beams experience diffraction-free propagation. The heterostructures composed of the MGSAs may find great applications in deep-subwavelength spatial light modulators, optical splitters, and switches.

  1. Refractive index as materials property. Der Brechungsindex als Stoffeigenschaft

    Energy Technology Data Exchange (ETDEWEB)

    Zilian, U. (Ciba-Geigy AG, Basel (Switzerland))

    1991-10-01

    The investigation of the relationship between refractive index (n) and molecular structure of a series of gases, liquids, and solids led to the conclusion that the refractive index of a substance is an independent molecular property. Light is refracted by two types of electron pairs. a) Bonding Electron Pairs (BEP) and b) Response Electron Pairs (REP). - Paraffins exhibit only BEPs which can easily be counted. REP is a new term we introduce to quantify the effects of several nonbonding electrons. The inert gases, for example, refract solely with REPs. They can be determined, and the most important ones are herein tabulated or delineated in the text. For compounds with known formular weight (M) and density (d), the refractive index can be simply calculated using the following formula. (orig.).

  2. Measurements of photoinduced refractive index changes in ...

    Indian Academy of Sciences (India)

    Abstract. We report the pump–probe measurements of nonlinear refractive index changes in photochromic bacteriorhodopsin films. The photoinduced absorption is caused by pump beam at 532 nm and the accompanying refractive index changes are studied using a probe beam at 633 nm. The proposed technique is ...

  3. Facts about Refractive Errors

    Science.gov (United States)

    ... NEI Intranet (Employees Only) *PDF files require the free Adobe® Reader® software for viewing. This website is maintained by the NEI Office of Science Communications, Public Liaison, and Education. Technical questions about this website can be addressed ...

  4. Refractive index inversion based on Mueller matrix method

    Science.gov (United States)

    Fan, Huaxi; Wu, Wenyuan; Huang, Yanhua; Li, Zhaozhao

    2016-03-01

    Based on Stokes vector and Jones vector, the correlation between Mueller matrix elements and refractive index was studied with the result simplified, and through Mueller matrix way, the expression of refractive index inversion was deduced. The Mueller matrix elements, under different incident angle, are simulated through the expression of specular reflection so as to analyze the influence of the angle of incidence and refractive index on it, which is verified through the measure of the Mueller matrix elements of polished metal surface. Research shows that, under the condition of specular reflection, the result of Mueller matrix inversion is consistent with the experiment and can be used as an index of refraction of inversion method, and it provides a new way for target detection and recognition technology.

  5. Crustal structure of Shatsky Rise from joint refraction and reflection seismic tomography

    Science.gov (United States)

    Korenaga, J.; Sager, W. W.

    2011-12-01

    Shatsky Rise in the western Pacific is one of a few gigantic oceanic plateaus in the world, with a surface area of ˜ 4.8 ± 105~km2 (about the same size as California). In contrast to other large oceanic plateaus formed during the Cretaceous Quite Period, Shatsky Rise formed during the frequent reversals of magnetic polarity, allowing its tectonic environment to be resolved in detail. It was formed at a rapidly spreading ridge-ridge-ridge triple junction, so the effect of lithospheric lid on magma migration is expected to be minimal, thereby facilitating the petrological interpretation of its seismic structure in terms of parental mantle processes. In the summer of 2010, a seismic refraction survey combined with multichannel seismic profiling was conducted across Shatsky Rise. Twenty eight ocean-bottom seismometers were deployed along two crossing perpendicular lines, and all of the instruments were recovered successfully, yielding a large volume of high-quality wide-angle refraction and reflection data, with the source-receiver distance often exceeding 200~km. In this contribution, we present the P-wave velocity structure of the Shatsky Rise crust, which is constructed by joint refraction and reflection travel time tomography, and also discuss its implications for the origin of Shatsky Rise.

  6. Influence of changes in an eye's optical system on refraction

    Science.gov (United States)

    Bartkowska, Janina

    1998-10-01

    The optical system of eye is composed of cornea, lens, anterior chamber, and vitreous body. In the standard schematic eye there are 6 refracting surfaces. The changes of the curvature radii, of the distances between them, of the refractive indices influence the ametropia, refractive power of the eye and retinal image size. The influence of these changes can be appreciated by ray tracing or by an analytical method. There are presented simplified formulae for the differentials of ametropia and refractive power of the eye with respect to the surfaces curvatures, refracting power of cornea and lens, refractive indices. The relations are valid too for bigger changes if ametropia is measured in the cornea vertex. The formulae for the differentials with respect to distances, lens translation, eye axis length are valid if ametropia is measured in the object focus of the eye.

  7. Conical Refraction: new observations and a dual cone model.

    Science.gov (United States)

    Sokolovskii, G S; Carnegie, D J; Kalkandjiev, T K; Rafailov, E U

    2013-05-06

    We propose a paraxial dual-cone model of conical refraction involving the interference of two cones of light behind the exit face of the crystal. The supporting experiment is based on beam selecting elements breaking down the conically refracted beam into two separate hollow cones which are symmetrical with one another. The shape of these cones of light is a product of a 'competition' between the divergence caused by the conical refraction and the convergence due to the focusing by the lens. The developed mathematical description of the conical refraction demonstrates an excellent agreement with experiment.

  8. Reduction of measurement errors in OCT scanning

    Science.gov (United States)

    Morel, E. N.; Tabla, P. M.; Sallese, M.; Torga, J. R.

    2018-03-01

    Optical coherence tomography (OCT) is a non-destructive optical technique, which uses a light source with a wide band width that focuses on a point in the sample to determine the distance (strictly, the optical path difference, OPD) between this point and a reference surface. The point can be superficial or at an interior interface of the sample (transparent or semitransparent), allowing topographies and / or tomographies in different materials. The Michelson interferometer is the traditional experimental scheme for this technique, in which a beam of light is divided into two arms, one the reference and the other the sample. The overlap of reflected light in the sample and in the reference generates an interference signal that gives us information about the OPD between arms. In this work, we work on the experimental configuration in which the reference signal and the reflected signal in the sample travel on the same arm, improving the quality of the interference signal. Among the most important aspects of this improvement we can mention that the noise and errors produced by the relative reference-sample movement and by the dispersion of the refractive index are considerably reduced. It is thus possible to obtain 3D images of surfaces with a spatial resolution in the order of microns. Results obtained on the topography of metallic surfaces, glass and inks printed on paper are presented.

  9. Synthesis of freeform refractive surfaces forming various radiation patterns using interpolation

    Science.gov (United States)

    Voznesenskaya, Anna; Mazur, Iana; Krizskiy, Pavel

    2017-09-01

    Optical freeform surfaces are very popular today in such fields as lighting systems, sensors, photovoltaic concentrators, and others. The application of such surfaces allows to obtain systems with a new quality with a reduced number of optical components to ensure high consumer characteristics: small size, weight, high optical transmittance. This article presents the methods of synthesis of refractive surface for a given source and the radiation pattern of various shapes using a computer simulation cubic spline interpolation.

  10. Fermat's principle and the formal equivalence of local light-ray rotation and refraction at the interface between homogeneous media with a complex refractive index ratio.

    Science.gov (United States)

    Sundar, Bhuvanesh; Hamilton, Alasdair C; Courtial, Johannes

    2009-02-01

    We derive a formal description of local light-ray rotation in terms of complex refractive indices. We show that Fermat's principle holds, and we derive an extended Snell's law. The change in the angle of a light ray with respect to the normal of a refractive index interface is described by the modulus of the refractive index ratio; the rotation around the interface normal is described by the argument of the refractive index ratio.

  11. Topography-modified refraction: adjustment of treated cylinder amount and axis to the topography versus standard clinical refraction in myopic topography-guided LASIK

    OpenAIRE

    Alpins, Noel

    2017-01-01

    Noel Alpins1,2 1NewVision Clinics, Melbourne, VIC, Australia; 2Department Ophthalmology, Melbourne University, Melbourne, VIC, Australia It is encouraging to see the results in the article by Kanellopoulos “Topography-modified refraction (TMR): adjustment of treated cylinder amount and axis to the topography versus standard clinical refraction in myopic topography-guided LASIK”,1 where the combination of refractive and corneal data in the treatment parameters pro...

  12. Influence of internal refractive index gradients on size measurements of spherically symmetric particles by phase Doppler anemometry.

    Science.gov (United States)

    Schneider, M; Hirleman, E D

    1994-04-20

    A model based on geometric optics for predicting the response of interferometric (phase Doppler) instruments for size measurements of particles with radially symmetric but inhomogeneous internal refractive index profiles is developed. The model and results are important for applications in which heat or mass transfer from the particles or droplets is significant, for example, in liquid-fuel combustion. To quantify the magnitude of potential bias errors introduced by the classical assumption of uniform internal properties on phase Doppler measurements, we compute calibration curves for a sequence of times during the evaporation of a decane droplet immersed in an environment of T = 2000 K and p = 10 bars. The results reveal considerable effects on the relation between phase difference and droplet diameter caused by the refractive index gradients present. The model provides an important tool to assess sizing uncertainties that can be expected when applying conventional (based on uniform properties) phase Doppler calibration curves in spray combustion and similar processes.

  13. Randomized clinical trials in dentistry: Risks of bias, risks of random errors, reporting quality, and methodologic quality over the years 1955-2013.

    Directory of Open Access Journals (Sweden)

    Humam Saltaji

    Full Text Available To examine the risks of bias, risks of random errors, reporting quality, and methodological quality of randomized clinical trials of oral health interventions and the development of these aspects over time.We included 540 randomized clinical trials from 64 selected systematic reviews. We extracted, in duplicate, details from each of the selected randomized clinical trials with respect to publication and trial characteristics, reporting and methodologic characteristics, and Cochrane risk of bias domains. We analyzed data using logistic regression and Chi-square statistics.Sequence generation was assessed to be inadequate (at unclear or high risk of bias in 68% (n = 367 of the trials, while allocation concealment was inadequate in the majority of trials (n = 464; 85.9%. Blinding of participants and blinding of the outcome assessment were judged to be inadequate in 28.5% (n = 154 and 40.5% (n = 219 of the trials, respectively. A sample size calculation before the initiation of the study was not performed/reported in 79.1% (n = 427 of the trials, while the sample size was assessed as adequate in only 17.6% (n = 95 of the trials. Two thirds of the trials were not described as double blinded (n = 358; 66.3%, while the method of blinding was appropriate in 53% (n = 286 of the trials. We identified a significant decrease over time (1955-2013 in the proportion of trials assessed as having inadequately addressed methodological quality items (P < 0.05 in 30 out of the 40 quality criteria, or as being inadequate (at high or unclear risk of bias in five domains of the Cochrane risk of bias tool: sequence generation, allocation concealment, incomplete outcome data, other sources of bias, and overall risk of bias.The risks of bias, risks of random errors, reporting quality, and methodological quality of randomized clinical trials of oral health interventions have improved over time; however, further efforts that contribute to the development of more stringent

  14. Optical negative refraction by four-wave mixing in thin metallic nanostructures.

    Science.gov (United States)

    Palomba, Stefano; Zhang, Shuang; Park, Yongshik; Bartal, Guy; Yin, Xiaobo; Zhang, Xiang

    2011-10-30

    The law of refraction first derived by Snellius and later introduced as the Huygens-Fermat principle, states that the incidence and refracted angles of a light wave at the interface of two different materials are related to the ratio of the refractive indices in each medium. Whereas all natural materials have a positive refractive index and therefore exhibit refraction in the positive direction, artificially engineered negative index metamaterials have been shown capable of bending light waves negatively. Such a negative refractive index is the key to achieving a perfect lens that is capable of imaging well below the diffraction limit. However, negative index metamaterials are typically lossy, narrow band, and require complicated fabrication processes. Recently, an alternative approach to obtain negative refraction from a very thin nonlinear film has been proposed and experimentally demonstrated in the microwave region. However, such approaches use phase conjugation, which makes optical implementations difficult. Here, we report a simple but different scheme to demonstrate experimentally nonlinear negative refraction at optical frequencies using four-wave mixing in nanostructured metal films. The refractive index can be designed at will by simply tuning the wavelengths of the interacting waves, which could have potential impact on many important applications, such as superlens imaging.

  15. Putting a face on medical errors: a patient perspective.

    Science.gov (United States)

    Kooienga, Sarah; Stewart, Valerie T

    2011-01-01

    Knowledge of the patient's perspective on medical error is limited. Research efforts have centered on how best to disclose error and how patients desire to have medical error disclosed. On the basis of a qualitative descriptive component of a mixed method study, a purposive sample of 30 community members told their stories of medical error. Their experiences focused on lack of communication, missed communication, or provider's poor interpersonal style of communication, greatly contrasting with the formal definition of error as failure to follow a set standard of care. For these participants, being a patient was more important than error or how an error is disclosed. The patient's understanding of error must be a key aspect of any quality improvement strategy. © 2010 National Association for Healthcare Quality.

  16. Study on the transverse chromatic aberration of the individual eye model after LASIK refractive surgery

    Science.gov (United States)

    Zhang, Mei; Wang, Zhao-Qi; Wang, Yan; Zuo, Tong

    2010-10-01

    The aim of this research is to study the properties of the transverse chromatic aberration (TCA) after the LASIK refractive surgery based on the individual eye model involving the angle between visual axis and optical axis. According to the measurements of the corneal surfaces, the optical axis lengths and the wavefront aberrations, the individual eye models before and after LASIK refractive surgery are constructed for 15 eyes by using ZEMAX optic design software, while the angle between the visual axis and optical axis is calculated from the data of the anterior corneal surface. The constructed eye models are then used to investigate the variation of the TCA after the surgery. The statistical distributions of the magnitude of the foveal TCA for 15 eyes over the visible spectrum are provided. Finally, we investigate the influence of the TCA on the visual quality and compare the results with previous research. The TCA is an indispensable criterion to evaluate the performance of the refractive surgery. This research is very meaningful for the studies of not only foveal vision but also the peripheral vision.

  17. Acoustic metasurface for refracted wave manipulation

    Science.gov (United States)

    Han, Li-Xiang; Yao, Yuan-Wei; Zhang, Xin; Wu, Fu-Gen; Dong, Hua-Feng; Mu, Zhong-Fei; Li, Jing-bo

    2018-02-01

    Here we present a design of a transmitted acoustic metasurface based on a single row of Helmholtz resonators with varying geometric parameters. The proposed metasurface can not only steer an acoustic beam as expected from the generalized Snell's law of refraction, but also exhibits various interesting properties and potential applications such as insulation of two quasi-intersecting transmitted sound waves, ultrasonic Bessel beam generator, frequency broadening effect of anomalous refraction and focusing.

  18. Combining zonal refractive and diffractive aspheric multifocal intraocular lenses.

    Science.gov (United States)

    Muñoz, Gonzalo; Albarrán-Diego, César; Javaloy, Jaime; Sakla, Hani F; Cerviño, Alejandro

    2012-03-01

    To assess visual performance with the combination of a zonal refractive aspheric multifocal intraocular lens (MIOL) (Lentis Mplus, Oculentis GmbH) and a diffractive aspheric MIOL (Acri.Lisa 366, Acri.Tech GmbH). This prospective interventional cohort study comprised 80 eyes from 40 cataract patients (mean age: 65.5±7.3 years) who underwent implantation of the Lentis Mplus MIOL in one eye and Acri.Lisa 366 MIOL in the fellow eye. The main outcome measures were refraction; monocular and binocular uncorrected and corrected distance, intermediate, and near visual acuities; monocular and binocular defocus curves; binocular photopic contrast sensitivity function compared to a monofocal intraocular lens (IOL) control group (40 age-matched pseudophakic patients implanted with the AR-40e [Abbott Medical Optics]); and quality of vision questionnaire. Binocular uncorrected visual acuities were 0.12 logMAR (0.76 decimal) or better at all distances measured between 6 m and 33 cm. The Lentis Mplus provided statistically significant better vision than the Acri.Lisa at distances between 2 m and 40 cm, and the Acri.Lisa provided statistically significant better vision than the Lentis Mplus at 33 cm. Binocular defocus curve showed little drop-off at intermediate distances. Photopic contrast sensitivity function for distance and near were similar to the monofocal IOL control group except for higher frequencies. Moderate glare (15%), night vision problems (12.5%), and halos (10%) were reported. Complete independence of spectacles was achieved by 92.5% of patients. The combination of zonal refractive aspheric and diffractive aspheric MIOLs resulted in excellent uncorrected binocular distance, intermediate, and near vision, with low incidence of significant photic phenomena and high patient satisfaction. Copyright 2012, SLACK Incorporated.

  19. Measurement of the refractive index dispersion of As2Se3 bulk glass and thin films prior to and after laser irradiation and annealing using prism coupling in the near- and mid-infrared spectral range

    International Nuclear Information System (INIS)

    Carlie, N.; Petit, L.; Musgraves, J. D.; Richardson, K.; Anheier, N. C. Jr.; Qiao, H. A.; Bernacki, B.; Phillips, M. C.

    2011-01-01

    The prism coupling technique has been utilized to measure the refractive index in the near- and mid-IR spectral region of chalcogenide glasses in bulk and thin film form. A commercial system (Metricon model 2010) has been modified with additional laser sources, detectors, and a new GaP prism to allow the measurement of refractive index dispersion over the 1.5-10.6 μm range. The instrumental error was found to be ±0.001 refractive index units across the entire wavelength region examined. Measurements on thermally evaporated AMTIR2 thin films confirmed that (i) the film deposition process provides thin films with reduced index compared to that of the bulk glass used as a target, (ii) annealing of the films increases the refractive index of the film to the level of the bulk glass used as a target to create it, and (iii) it is possible to locally increase the refractive index of the chalcogenide glass using laser exposure at 632.8 nm.

  20. High temperature refractive indices of GaN

    Energy Technology Data Exchange (ETDEWEB)

    Liu, C.; Stepanov, S.; Gott, A.; Shields, P.A.; Zhirnov, E.; Wang, W.N. [Department of Physics, University of Bath, Bath, BA2 7AY (United Kingdom); Steimetz, E.; Zettler, J.T. [LayTec, Helmholtzstr. 13-14, 10587 Berlin (Germany)

    2006-06-15

    Undoped GaN (u-GaN) films were grown by low pressure metalorganic vapour phase epitaxy (LP-MOVPE) on sapphire substrates. In situ optical monitoring was applied to the growth process either using a LayTec EpiR-DA TT spectroscopic reflectometer or Filmetrics F30. Refractive indices of u-GaN films at 1060 C were obtained in a spectral range from 370-900 nm. A peak at 412{+-}5 nm in refractive index spectra was observed, which most likely corresponds to the band-gap of hexagonal GaN at a temperature of 1060 C. Refractive indices below this band-gap are fitted well to the first-order Sellmeier formula. As an example of the applications of the refractive indices, the effective film thicknesses of GaN during the resumption from 3 dimensional (3D) to 2 dimensional (2D) growth have been calculated from the spectra recorded by a LayTec system using the optical constants obtained. (copyright 2006 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  1. Bioinspired adaptive gradient refractive index distribution lens

    Science.gov (United States)

    Yin, Kezhen; Lai, Chuan-Yar; Wang, Jia; Ji, Shanzuo; Aldridge, James; Feng, Jingxing; Olah, Andrew; Baer, Eric; Ponting, Michael

    2018-02-01

    Inspired by the soft, deformable human eye lens, a synthetic polymer gradient refractive index distribution (GRIN) lens with an adaptive geometry and focal power has been demonstrated via multilayer coextrusion and thermoforming of nanolayered elastomeric polymer films. A set of 30 polymer nanolayered films comprised of two thermoplastic polyurethanes having a refractive index difference of 0.05 were coextruded via forced-assembly technique. The set of 30 nanolayered polymer films exhibited transmission near 90% with each film varying in refractive index by 0.0017. An adaptive GRIN lens was fabricated from a laminated stack of the variable refractive index films with a 0.05 spherical GRIN. This lens was subsequently deformed by mechanical ring compression of the lens. Variation in the optical properties of the deformable GRIN lens was determined, including 20% variation in focal length and reduced spherical aberration. These properties were measured and compared to simulated results by placido-cone topography and ANSYS methods. The demonstration of a solid-state, dynamic focal length, GRIN lens with improved aberration correction was discussed relative to the potential future use in implantable devices.

  2. Trauma Quality Improvement: Reducing Triage Errors by Automating the Level Assignment Process.

    Science.gov (United States)

    Stonko, David P; O Neill, Dillon C; Dennis, Bradley M; Smith, Melissa; Gray, Jeffrey; Guillamondegui, Oscar D

    2018-04-12

    Trauma patients are triaged by the severity of their injury or need for intervention while en route to the trauma center according to trauma activation protocols that are institution specific. Significant research has been aimed at improving these protocols in order to optimize patient outcomes while striving for efficiency in care. However, it is known that patients are often undertriaged or overtriaged because protocol adherence remains imperfect. The goal of this quality improvement (QI) project was to improve this adherence, and thereby reduce the triage error. It was conducted as part of the formal undergraduate medical education curriculum at this institution. A QI team was assembled and baseline data were collected, then 2 Plan-Do-Study-Act (PDSA) cycles were implemented sequentially. During the first cycle, a novel web tool was developed and implemented in order to automate the level assignment process (it takes EMS-provided data and automatically determines the level); the tool was based on the existing trauma activation protocol. The second PDSA cycle focused on improving triage accuracy in isolated, less than 10% total body surface area burns, which we identified to be a point of common error. Traumas were reviewed and tabulated at the end of each PDSA cycle, and triage accuracy was followed with a run chart. This study was performed at Vanderbilt University Medical Center and Medical School, which has a large level 1 trauma center covering over 75,000 square miles, and which sees urban, suburban, and rural trauma. The baseline assessment period and each PDSA cycle lasted 2 weeks. During this time, all activated, adult, direct traumas were reviewed. There were 180 patients during the baseline period, 189 after the first test of change, and 150 after the second test of change. All were included in analysis. Of 180 patients, 30 were inappropriately triaged during baseline analysis (3 undertriaged and 27 overtriaged) versus 16 of 189 (3 undertriaged and 13

  3. Experimental refractive index determination of the optic fiber's core

    International Nuclear Information System (INIS)

    Oezelsoy, S.

    2005-01-01

    In this work, the Fresnel's fundamental Law was used to be able to obtain the refractive index of the fiber optic's core. The intensity of light reflected from the boundary between two mediums was measured by the optical powermeter (Melles Griot, Universal optical powermeter). In recent technology, the light that is illuminated from the light source can be transported to the boundary region and measured with minimum loss by using the optic fibers which make the measurement more sensitively. The liquid and the optic fiber's core whose refractive indices will be measured are the two mediums and the surface of the optic fiber's core is the boundary region. By dipping the fiber optic probe to the liquids, the reflected light intensities were measured with powermeter via Silicon Detector for single mode fiber and multimode fiber respectively to obtain the refractive index of the optic fiber's core. At this work, because of the using the diode laser with 661,4 nm (FWHM) and He-Ne laser with 632,8 nm (FWHM) the refractive indices were measured at this wavelengthes with the Refractometer (Abbe 60-70, Bellingham+Stanley). If the refractive indices of two mediums are equal, the light doesn't reflect from the boundary. The graphic is drawn depend upon the refractive index of the liquids versus the back reflected light energy and from the minimum point of the curve the effective refractive index of the fiber optic's core is calculated for 661,4 nm and 780 nm

  4. Black and gray Helmholtz-Kerr soliton refraction

    International Nuclear Information System (INIS)

    Sanchez-Curto, Julio; Chamorro-Posada, Pedro; McDonald, Graham S.

    2011-01-01

    Refraction of black and gray solitons at boundaries separating different defocusing Kerr media is analyzed within a Helmholtz framework. A universal nonlinear Snell's law is derived that describes gray soliton refraction, in addition to capturing the behavior of bright and black Kerr solitons at interfaces. Key regimes, defined by beam and interface characteristics, are identified, and predictions are verified by full numerical simulations. The existence of a unique total nonrefraction angle for gray solitons is reported; both internal and external refraction at a single interface is shown possible (dependent only on incidence angle). This, in turn, leads to the proposal of positive or negative lensing operations on soliton arrays at planar boundaries.

  5. Different grades MEMS accelerometers error characteristics

    Science.gov (United States)

    Pachwicewicz, M.; Weremczuk, J.

    2017-08-01

    The paper presents calibration effects of two different MEMS accelerometers of different price and quality grades and discusses different accelerometers errors types. The calibration for error determining is provided by reference centrifugal measurements. The design and measurement errors of the centrifuge are discussed as well. It is shown that error characteristics of the sensors are very different and it is not possible to use simple calibration methods presented in the literature in both cases.

  6. THE OPTICS OF REFRACTIVE SUBSTRUCTURE

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, Michael D.; Narayan, Ramesh, E-mail: mjohnson@cfa.harvard.edu [Harvard-Smithsonian Center for Astrophysics, 60 Garden Street, Cambridge, MA 02138 (United States)

    2016-08-01

    Newly recognized effects of refractive scattering in the ionized interstellar medium have broad implications for very long baseline interferometry (VLBI) at extreme angular resolutions. Building upon work by Blandford and Narayan, we present a simplified, geometrical optics framework, which enables rapid, semi-analytic estimates of refractive scattering effects. We show that these estimates exactly reproduce previous results based on a more rigorous statistical formulation. We then derive new expressions for the scattering-induced fluctuations of VLBI observables such as closure phase, and we demonstrate how to calculate the fluctuations for arbitrary quantities of interest using a Monte Carlo technique.

  7. Errors in estimating neutron quality factor using lineal energy distributions measured in tissue-equivalent proportional counters

    International Nuclear Information System (INIS)

    Borak, T.B.; Stinchcomb, T.G.

    1982-01-01

    Neutron dose equivalent is obtained from quality factors which are defined in terms of LET. It is possible to estimate the dose averaged quality factor, antiQ, directly from distributions in lineal energy, y, that are measured in tissue-equivalent proportional counters. This eliminates a mathematical transformation of the absorbed dose from D(y) to D(L). We evaluate the inherent error in computing Q from D(y) rather than D(L) for neutron spectra below 4 MeV. The effects of neutron energy and simulated tissue diameters within a gas cavity are examined in detail. (author)

  8. Ultraviolet light induced refractive index structures in germanosilica

    DEFF Research Database (Denmark)

    Svalgaard, Mikael

    1997-01-01

    The focus of the research presented in this ph.d. thesis is refractive index structures photoinduced in germanonsilica waveguides with ultra-violet (UV) radiation. The physical mechanisms involved in photosensitivity and applications of a wide range of UV induced refractive index structures in both...... application of a scanning near-field optical microscope to obtain high resolution images of UV induced refractive index structures and by monitoring the dynamics of UV induced index changes and luminescence. During part of my ph.d. project I have worked at the National Institute of Standards and Technolgy...

  9. A note on "An economic order quantity (EOQ for items with imperfect quality and inspection errors"

    Directory of Open Access Journals (Sweden)

    Lie-Fern Hsu

    2012-08-01

    Full Text Available In a previously published paper by Khan et al. (2011 [Khan, M., Jaber, M.Y., & Bonney M. (2011. An economic order quantity (EOQ for items with imperfect quality and inspection errors, International Journal of Production Economics, 133, 113-118], we found that there is a contradiction between the cycle length and the holding cost per cycle. To obtain the cycle length, the authors assumed that the returned items from the market were replaced with good quality items. However, for the holding cost per cycle, the authors implicitly assumed that the returned items were not replaced by good quality items. In this note, we first point out the contradiction. Then we fix this flaw and develop a corrected EOQ.

  10. Prioritising interventions against medication errors

    DEFF Research Database (Denmark)

    Lisby, Marianne; Pape-Larsen, Louise; Sørensen, Ann Lykkegaard

    errors are therefore needed. Development of definition: A definition of medication errors including an index of error types for each stage in the medication process was developed from existing terminology and through a modified Delphi-process in 2008. The Delphi panel consisted of 25 interdisciplinary......Abstract Authors: Lisby M, Larsen LP, Soerensen AL, Nielsen LP, Mainz J Title: Prioritising interventions against medication errors – the importance of a definition Objective: To develop and test a restricted definition of medication errors across health care settings in Denmark Methods: Medication...... errors constitute a major quality and safety problem in modern healthcare. However, far from all are clinically important. The prevalence of medication errors ranges from 2-75% indicating a global problem in defining and measuring these [1]. New cut-of levels focusing the clinical impact of medication...

  11. Quality prediction modeling for sintered ores based on mechanism models of sintering and extreme learning machine based error compensation

    Science.gov (United States)

    Tiebin, Wu; Yunlian, Liu; Xinjun, Li; Yi, Yu; Bin, Zhang

    2018-06-01

    Aiming at the difficulty in quality prediction of sintered ores, a hybrid prediction model is established based on mechanism models of sintering and time-weighted error compensation on the basis of the extreme learning machine (ELM). At first, mechanism models of drum index, total iron, and alkalinity are constructed according to the chemical reaction mechanism and conservation of matter in the sintering process. As the process is simplified in the mechanism models, these models are not able to describe high nonlinearity. Therefore, errors are inevitable. For this reason, the time-weighted ELM based error compensation model is established. Simulation results verify that the hybrid model has a high accuracy and can meet the requirement for industrial applications.

  12. Estimation of network parameters with consideration of the horizontal refraction influence

    Directory of Open Access Journals (Sweden)

    Ján Ježko

    2007-06-01

    Full Text Available The proposed paper is focused on reviewing the horizontal refraction during measurement in local geodetic networks. Based on elaborated theoretical assumptions the refraction model was arranged in a way that the questions were solved by the identity of the horizontal refraction. The necessary part of the application of the refraction model is the problem of optimizing the geodetic networks and deducting the method of the variance components, which play a major role in the precision of results. The independent acquisition of the thesis lies in the area of modeling the horizontal refraction with a stochastic approach, where the values of the refraction are gained through the measured data of the horizontal direction. In the model, it is necessary to identify the parameters according to the entire measurements and between two points. According to the attained results, I can state that the horizontal refraction was identified mainly on the measurements that were confirmed near the dam in most of the measured experiments. The experimented measurements were confirmed based on the assumptions that are in theoretical capitol, where the assumptions of the effect of the horizontal refraction are measured near the dam, river, shores, and valleys.

  13. The predicted CLARREO sampling error of the inter-annual SW variability

    Science.gov (United States)

    Doelling, D. R.; Keyes, D. F.; Nguyen, C.; Macdonnell, D.; Young, D. F.

    2009-12-01

    The NRC Decadal Survey has called for SI traceability of long-term hyper-spectral flux measurements in order to monitor climate variability. This mission is called the Climate Absolute Radiance and Refractivity Observatory (CLARREO) and is currently defining its mission requirements. The requirements are focused on the ability to measure decadal change of key climate variables at very high accuracy. The accuracy goals are set using anticipated climate change magnitudes, but the accuracy achieved for any given climate variable must take into account the temporal and spatial sampling errors based on satellite orbits and calibration accuracy. The time period to detect a significant trend in the CLARREO record depends on the magnitude of the sampling calibration errors relative to the current inter-annual variability. The largest uncertainty in climate feedbacks remains the effect of changing clouds on planetary energy balance. Some regions on earth have strong diurnal cycles, such as maritime stratus and afternoon land convection; other regions have strong seasonal cycles, such as the monsoon. However, when monitoring inter-annual variability these cycles are only important if the strength of these cycles vary on decadal time scales. This study will attempt to determine the best satellite constellations to reduce sampling error and to compare the error with the current inter-annual variability signal to ensure the viability of the mission. The study will incorporate Clouds and the Earth's Radiant Energy System (CERES) (Monthly TOA/Surface Averages) SRBAVG product TOA LW and SW climate quality fluxes. The fluxes are derived by combining Terra (10:30 local equator crossing time) CERES fluxes with 3-hourly 5-geostationary satellite estimated broadband fluxes, which are normalized using the CERES fluxes, to complete the diurnal cycle. These fluxes were saved hourly during processing and considered the truth dataset. 90°, 83° and 74° inclination precessionary orbits as

  14. Femtosecond laser-assisted LASIK versus PRK for high myopia: comparison of 18-month visual acuity and quality.

    Science.gov (United States)

    Hashemi, Hassan; Ghaffari, Reza; Miraftab, Mohammad; Asgari, Soheila

    2017-08-01

    To compare 18-month outcomes between femtosecond laser-assisted LASIK (femto-LASIK) and photorefractive keratectomy with mitomycin-C (PRK-MMC) for myopia of more than 7.0 D in terms of visual acuity and quality. In this comparative nonrandomized clinical trial, 60 eyes from 30 patients (30 eyes in each group) were enrolled. The two procedures were compared in terms of 18-month changes in uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), manifest refraction spherical equivalent, ocular and corneal higher order aberrations (HOAs), and contrast sensitivity (CS). Mean myopia was -8.65 ± 1.51 and -8.04 ± 1.70 D (P = 0.149) and mean ablation depth was 109.37 ± 9.07 and 105.09 ± 12.59 µm (P = 0.138), in the femto-LASIK and PRK-MMC groups, respectively. Baseline parameters were not significantly different between the two groups (all P > 0.05). At 18 months postoperatively, 75 % in the femto-LASIK, versus 57.1 % in the PRK-MMC group, had 20/20 UDVA (P = 0.017). CDVA remained similarly unchanged in both groups (P = 0.616). No case had residual refractive error more than 1.0 D in the femto-LASIK group, while 33.5 % in the other group had more than 1.0 D residual error (P = 0.390). Changes in corneal HOA were not significantly different between the two groups (P = 0.260). Cases in the femto-LASIK group showed more increase in ocular HOA (P = 0.032) and coma (P = 0.083, power = 72 %). CS remained similarly unchanged in all spatial frequencies in both groups (all P > 0.05). Although femto-LASIK induces more HOA compared to PRK-MMC, considering outcomes in terms of 20/20 UDVA, residual refractive error, and CS stability, femto-LASIK provides more favorable results than PRK-MMC in high myopia.

  15. Impact of Educational Activities in Reducing Pre-Analytical Laboratory Errors: A quality initiative.

    Science.gov (United States)

    Al-Ghaithi, Hamed; Pathare, Anil; Al-Mamari, Sahimah; Villacrucis, Rodrigo; Fawaz, Naglaa; Alkindi, Salam

    2017-08-01

    Pre-analytic errors during diagnostic laboratory investigations can lead to increased patient morbidity and mortality. This study aimed to ascertain the effect of educational nursing activities on the incidence of pre-analytical errors resulting in non-conforming blood samples. This study was conducted between January 2008 and December 2015. All specimens received at the Haematology Laboratory of the Sultan Qaboos University Hospital, Muscat, Oman, during this period were prospectively collected and analysed. Similar data from 2007 were collected retrospectively and used as a baseline for comparison. Non-conforming samples were defined as either clotted samples, haemolysed samples, use of the wrong anticoagulant, insufficient quantities of blood collected, incorrect/lack of labelling on a sample or lack of delivery of a sample in spite of a sample request. From 2008 onwards, multiple educational training activities directed at the hospital nursing staff and nursing students primarily responsible for blood collection were implemented on a regular basis. After initiating corrective measures in 2008, a progressive reduction in the percentage of non-conforming samples was observed from 2009 onwards. Despite a 127.84% increase in the total number of specimens received, there was a significant reduction in non-conforming samples from 0.29% in 2007 to 0.07% in 2015, resulting in an improvement of 75.86% ( P educational activities directed primarily towards hospital nursing staff had a positive impact on the quality of laboratory specimens by significantly reducing pre-analytical errors.

  16. TAKE, development of the refractive index measurement technology for industrial needs; TAKE, taitekerroinmittaustekniikan kehittaeminen teollisuuden tarpeisiin - MPKT 12

    Energy Technology Data Exchange (ETDEWEB)

    Raety, J. [Oulu Univ. (Finland)

    1998-12-31

    Refractive index is one of the basic physical phenomena of materials. Traditional refractive index measurement has been widely used e.g. In research, in quality inspection of products and raw materials. It is also used for follow up of the different industrial processes. A measuring and research environment, by which it is possible to determine the complex refractive index of liquid samples, was developed in 1996 at the Measuring Instrument laboratory of the University of Oulu. This equipment, based on the reflectance of light measures both the refractive index and absorption factor of liquids simultaneously. While the commercial refractometers are best suitable for research of clear liquids, by the developed equipment it is possible to investigate by the side of clear fluids also dark strongly light absorbing samples. The measuring wave length can be chosen continuously inside the UV-Visual range. The knowing of the wave-length dependence of the complex refractive index gives additional information on the state of the fluid under inspection. The main objective of the task is to solve measuring problems of biotechnology, food industry and forest industry by a new type of refractometric method. This means the simultaneous measurement of refractive index and absorption, and the utilisation of this knowledge in wide spectral region. A refractometer, based on the technology, suitable for applied research of new measuring targets will be designed and constructed in the research. The above mentioned goals also require the survey of the present situation of the refractometry. This one and a half year project will be started in spring 1998. (orig.)

  17. TAKE, development of the refractive index measurement technology for industrial needs; TAKE, taitekerroinmittaustekniikan kehittaeminen teollisuuden tarpeisiin - MPKT 12

    Energy Technology Data Exchange (ETDEWEB)

    Raety, J [Oulu Univ. (Finland)

    1999-12-31

    Refractive index is one of the basic physical phenomena of materials. Traditional refractive index measurement has been widely used e.g. In research, in quality inspection of products and raw materials. It is also used for follow up of the different industrial processes. A measuring and research environment, by which it is possible to determine the complex refractive index of liquid samples, was developed in 1996 at the Measuring Instrument laboratory of the University of Oulu. This equipment, based on the reflectance of light measures both the refractive index and absorption factor of liquids simultaneously. While the commercial refractometers are best suitable for research of clear liquids, by the developed equipment it is possible to investigate by the side of clear fluids also dark strongly light absorbing samples. The measuring wave length can be chosen continuously inside the UV-Visual range. The knowing of the wave-length dependence of the complex refractive index gives additional information on the state of the fluid under inspection. The main objective of the task is to solve measuring problems of biotechnology, food industry and forest industry by a new type of refractometric method. This means the simultaneous measurement of refractive index and absorption, and the utilisation of this knowledge in wide spectral region. A refractometer, based on the technology, suitable for applied research of new measuring targets will be designed and constructed in the research. The above mentioned goals also require the survey of the present situation of the refractometry. This one and a half year project will be started in spring 1998. (orig.)

  18. Characteristics of pediatric chemotherapy medication errors in a national error reporting database.

    Science.gov (United States)

    Rinke, Michael L; Shore, Andrew D; Morlock, Laura; Hicks, Rodney W; Miller, Marlene R

    2007-07-01

    Little is known regarding chemotherapy medication errors in pediatrics despite studies suggesting high rates of overall pediatric medication errors. In this study, the authors examined patterns in pediatric chemotherapy errors. The authors queried the United States Pharmacopeia MEDMARX database, a national, voluntary, Internet-accessible error reporting system, for all error reports from 1999 through 2004 that involved chemotherapy medications and patients aged error reports, 85% reached the patient, and 15.6% required additional patient monitoring or therapeutic intervention. Forty-eight percent of errors originated in the administering phase of medication delivery, and 30% originated in the drug-dispensing phase. Of the 387 medications cited, 39.5% were antimetabolites, 14.0% were alkylating agents, 9.3% were anthracyclines, and 9.3% were topoisomerase inhibitors. The most commonly involved chemotherapeutic agents were methotrexate (15.3%), cytarabine (12.1%), and etoposide (8.3%). The most common error types were improper dose/quantity (22.9% of 327 cited error types), wrong time (22.6%), omission error (14.1%), and wrong administration technique/wrong route (12.2%). The most common error causes were performance deficit (41.3% of 547 cited error causes), equipment and medication delivery devices (12.4%), communication (8.8%), knowledge deficit (6.8%), and written order errors (5.5%). Four of the 5 most serious errors occurred at community hospitals. Pediatric chemotherapy errors often reached the patient, potentially were harmful, and differed in quality between outpatient and inpatient areas. This study indicated which chemotherapeutic agents most often were involved in errors and that administering errors were common. Investigation is needed regarding targeted medication administration safeguards for these high-risk medications. Copyright (c) 2007 American Cancer Society.

  19. Pressure-dependent refractive indices of gases by THz time-domain spectroscopy.

    Science.gov (United States)

    Sang, Bark Hyeon; Jeon, Tea-In

    2016-12-12

    Noncontact terahertz time-domain spectroscopy was employed to measure pressure-dependent refractive indices of gases such as helium (He), argon (Ar), krypton (Kr), oxygen (O2), nitrogen (N2), methane (CH4), and carbon dioxide (CO2). The refractive indices of these gases scaled linearly with pressure, for pressures in the 55-3,750 torr range. At the highest pressure, the refractive indices ((n-1) x 106) of He and CO2 were 170 and 2,390, respectively. The refractive index of CO2 was 14.1-fold higher than that of He, owing to the stronger polarizability of CO2. Although the studied gases differed in terms of their molecular structure, their refractive indices were strongly determined by polarizability. The measured refractive indices agreed well with the theoretical calculations.

  20. A Comprehensive Quality Assurance Program for Personnel and Procedures in Radiation Oncology: Value of Voluntary Error Reporting and Checklists

    International Nuclear Information System (INIS)

    Kalapurakal, John A.; Zafirovski, Aleksandar; Smith, Jeffery; Fisher, Paul; Sathiaseelan, Vythialingam; Barnard, Cynthia; Rademaker, Alfred W.; Rave, Nick; Mittal, Bharat B.

    2013-01-01

    Purpose: This report describes the value of a voluntary error reporting system and the impact of a series of quality assurance (QA) measures including checklists and timeouts on reported error rates in patients receiving radiation therapy. Methods and Materials: A voluntary error reporting system was instituted with the goal of recording errors, analyzing their clinical impact, and guiding the implementation of targeted QA measures. In response to errors committed in relation to treatment of the wrong patient, wrong treatment site, and wrong dose, a novel initiative involving the use of checklists and timeouts for all staff was implemented. The impact of these and other QA initiatives was analyzed. Results: From 2001 to 2011, a total of 256 errors in 139 patients after 284,810 external radiation treatments (0.09% per treatment) were recorded in our voluntary error database. The incidence of errors related to patient/tumor site, treatment planning/data transfer, and patient setup/treatment delivery was 9%, 40.2%, and 50.8%, respectively. The compliance rate for the checklists and timeouts initiative was 97% (P<.001). These and other QA measures resulted in a significant reduction in many categories of errors. The introduction of checklists and timeouts has been successful in eliminating errors related to wrong patient, wrong site, and wrong dose. Conclusions: A comprehensive QA program that regularly monitors staff compliance together with a robust voluntary error reporting system can reduce or eliminate errors that could result in serious patient injury. We recommend the adoption of these relatively simple QA initiatives including the use of checklists and timeouts for all staff to improve the safety of patients undergoing radiation therapy in the modern era

  1. Refractive and ocular biometric profile of children with a history of laser treatment for retinopathy of prematurity

    Science.gov (United States)

    Kaur, Savleen; Sukhija, Jaspreet; Katoch, Deeksha; Sharma, Mansi; Samanta, Ramanuj; Dogra, Mangat R

    2017-01-01

    Purpose: Indian children belong to a diverse socioeconomic strata with retinopathy of prematurity (ROP) developing in mature, higher birth weight babies as well. The purpose of our study is to analyze the long-term status of refractive errors and its relationship with ocular biometry in children with ROP who were laser treated at a tertiary center in North India. Methods: Cross sectional study. Children (biometric status. Results: Thirty-six children presenting to us at the mean age of 7.37 ± 3.07 years (6–15 years) were included. Mean spherical equivalent (SE) was −4.05 D ± 5.10. 75% were myopic, with high astigmatism in 31%. Higher lens thickness (P = 0.03) and higher SE (P = 0.002) at 1 year postnatal age were predictors of larger SE. 79.4% achieved a favorable functional outcome (visual acuity ≥20/40). 5.88% achieved unsatisfactory outcome (<20/200) despite having a favorable structural outcome. Conclusion: There are a substantial number of children who develop myopia and high astigmatism while undergoing laser treatment for ROP. We found myopia in our cohort to be lenticular and greater axial length contributing to the development of high myopia. An initial large refractive error predicts the future development of myopia in these children. Nearly 6% of patients with good structural outcome have unexplained subnormal vision. Our threshold for prescribing glasses in these children should be low. PMID:28905827

  2. Measurement of Refractive Index Using a Michelson Interferometer.

    Science.gov (United States)

    Fendley, J. J.

    1982-01-01

    Describes a novel and simple method of measuring the refractive index of transparent plates using a Michelson interferometer. Since it is necessary to use a computer program when determining the refractive index, undergraduates could be given the opportunity of writing their own programs. (Author/JN)

  3. Wave propagation simulation of radio occultations based on ECMWF refractivity profiles

    DEFF Research Database (Denmark)

    von Benzon, Hans-Henrik; Høeg, Per

    2015-01-01

    This paper describes a complete radio occultation simulation environment, including realistic refractivity profiles, wave propagation modeling, instrument modeling, and bending angle retrieval. The wave propagator is used to simulate radio occultation measurements. The radio waves are propagated...... of radio occultations. The output from the wave propagator simulator is used as input to a Full Spectrum Inversion retrieval module which calculates geophysical parameters. These parameters can be compared to the ECMWF atmospheric profiles. The comparison can be used to reveal system errors and get...... a better understanding of the physics. The wave propagation simulations will in this paper also be compared to real measurements. These radio occultations have been exposed to the same atmospheric conditions as the radio occultations simulated by the wave propagator. This comparison reveals that precise...

  4. Perfect imaging without negative refraction

    Energy Technology Data Exchange (ETDEWEB)

    Leonhardt, Ulf [School of Physics and Astronomy, University of St Andrews, North Haugh, St Andrews KY16 9SS (United Kingdom)], E-mail: ulf@st-andrews.ac.uk

    2009-09-15

    Perfect imaging has been believed to rely on negative refraction, but here we show that an ordinary positively refracting optical medium may form perfect images as well. In particular, we establish a mathematical proof that Maxwell's fish eye in two-dimensional (2D) integrated optics makes a perfect instrument with a resolution not limited by the wavelength of light. We also show how to modify the fish eye such that perfect imaging devices can be made in practice. Our method of perfect focusing may also find applications outside of optics, in acoustics, fluid mechanics or quantum physics, wherever waves obey the 2D Helmholtz equation.

  5. Computational error and complexity in science and engineering computational error and complexity

    CERN Document Server

    Lakshmikantham, Vangipuram; Chui, Charles K; Chui, Charles K

    2005-01-01

    The book "Computational Error and Complexity in Science and Engineering” pervades all the science and engineering disciplines where computation occurs. Scientific and engineering computation happens to be the interface between the mathematical model/problem and the real world application. One needs to obtain good quality numerical values for any real-world implementation. Just mathematical quantities symbols are of no use to engineers/technologists. Computational complexity of the numerical method to solve the mathematical model, also computed along with the solution, on the other hand, will tell us how much computation/computational effort has been spent to achieve that quality of result. Anyone who wants the specified physical problem to be solved has every right to know the quality of the solution as well as the resources spent for the solution. The computed error as well as the complexity provide the scientific convincing answer to these questions. Specifically some of the disciplines in which the book w...

  6. [Accuracy of three common optometry methods in examination of refraction in juveniles].

    Science.gov (United States)

    Su, Ting; Min, Xiaoshan; Liu, Shuangzhen; Li, Fengyun; Tan, Xingping; Zhong, Yanni; Deng, Shaoling

    2016-02-01

    To compare the results of the three methods of Suresight handheld autorefractor, table-mounted autorefractor and retinoscopy in examination of juveniles patients with or without cycloplegia.
 Firstly, 156 eyes of 78 juveniles (5 to 17 years old) were examined by using WelchAllyn Suresight handheld autorefractor and NIDEK ARK-510A table-mounted autorefractor with or without cycloplegia; secondly, retinoscopy was performed with cycloplegia.
 The spherical power measured by methods without cycloplegia were significantly greater than those measured with cycloplegia (P0.05). These results were highly consistent, suggesting a tendency towards a short sight. However, the spherical power and cylindrical power measured by table-mounted autorefractor was significantly different (Poptometry, retinoscopy should be the gold standard for measuring refractive errors.

  7. Development of Uncertainty Quantification Method for MIR-PIV Measurement using BOS Technique

    International Nuclear Information System (INIS)

    Seong, Jee Hyun; Song, Min Seop; Kim, Eung Soo

    2014-01-01

    Matching Index of Refraction (MIR) is frequently used for obtaining high quality PIV measurement data. ven small distortion by unmatched refraction index of test section can result in uncertainty problems. In this context, it is desirable to construct new concept for checking errors of MIR and following uncertainty of PIV measurement. This paper proposes a couple of experimental concept and relative results. This study developed an MIR uncertainty quantification method for PIV measurement using SBOS technique. From the reference data of the BOS, the reliable SBOS experiment procedure was constructed. Then with the combination of SBOS technique with MIR-PIV technique, velocity vector and refraction displacement vector field was measured simultaneously. MIR errors are calculated through mathematical equation, in which PIV and SBOS data are put. These errors are also verified by another BOS experiment. Finally, with the applying of calculated MIR-PIV uncertainty, correct velocity vector field can be obtained regardless of MIR errors

  8. Implication of spot position error on plan quality and patient safety in pencil-beam-scanning proton therapy

    Energy Technology Data Exchange (ETDEWEB)

    Yu, Juan; Beltran, Chris J., E-mail: beltran.chris@mayo.edu; Herman, Michael G. [Division of Medical Physics, Department of Radiation Oncology, Mayo Clinic, Rochester, Minnesota 55905 (United States)

    2014-08-15

    Purpose: To quantitatively and systematically assess dosimetric effects induced by spot positioning error as a function of spot spacing (SS) on intensity-modulated proton therapy (IMPT) plan quality and to facilitate evaluation of safety tolerance limits on spot position. Methods: Spot position errors (PE) ranging from 1 to 2 mm were simulated. Simple plans were created on a water phantom, and IMPT plans were calculated on two pediatric patients with a brain tumor of 28 and 3 cc, respectively, using a commercial planning system. For the phantom, a uniform dose was delivered to targets located at different depths from 10 to 20 cm with various field sizes from 2{sup 2} to 15{sup 2} cm{sup 2}. Two nominal spot sizes, 4.0 and 6.6 mm of 1 σ in water at isocenter, were used for treatment planning. The SS ranged from 0.5 σ to 1.5 σ, which is 2–6 mm for the small spot size and 3.3–9.9 mm for the large spot size. Various perturbation scenarios of a single spot error and systematic and random multiple spot errors were studied. To quantify the dosimetric effects, percent dose error (PDE) depth profiles and the value of percent dose error at the maximum dose difference (PDE [ΔDmax]) were used for evaluation. Results: A pair of hot and cold spots was created per spot shift. PDE[ΔDmax] is found to be a complex function of PE, SS, spot size, depth, and global spot distribution that can be well defined in simple models. For volumetric targets, the PDE [ΔDmax] is not noticeably affected by the change of field size or target volume within the studied ranges. In general, reducing SS decreased the dose error. For the facility studied, given a single spot error with a PE of 1.2 mm and for both spot sizes, a SS of 1σ resulted in a 2% maximum dose error; a SS larger than 1.25 σ substantially increased the dose error and its sensitivity to PE. A similar trend was observed in multiple spot errors (both systematic and random errors). Systematic PE can lead to noticeable hot

  9. On the optical path length in refracting media

    Science.gov (United States)

    Hasbun, Javier E.

    2018-04-01

    The path light follows as it travels through a substance depends on the substance's index of refraction. This path is commonly known as the optical path length (OPL). In geometrical optics, the laws of reflection and refraction are simple examples for understanding the path of light travel from source to detector for constant values of the traveled substances' refraction indices. In more complicated situations, the Euler equation can be quite useful and quite important in optics courses. Here, the well-known Euler differential equation (EDE) is used to obtain the OPL for several index of refraction models. For pedagogical completeness, the OPL is also obtained through a modified Monte Carlo (MC) method, versus which the various results obtained through the EDE are compared. The examples developed should be important in projects involving undergraduate as well as graduate students in an introductory optics course. A simple matlab script (program) is included that can be modified by students who wish to pursue the subject further.

  10. Improving image quality in Electrical Impedance Tomography (EIT using Projection Error Propagation-based Regularization (PEPR technique: A simulation study

    Directory of Open Access Journals (Sweden)

    Tushar Kanti Bera

    2011-03-01

    Full Text Available A Projection Error Propagation-based Regularization (PEPR method is proposed and the reconstructed image quality is improved in Electrical Impedance Tomography (EIT. A projection error is produced due to the misfit of the calculated and measured data in the reconstruction process. The variation of the projection error is integrated with response matrix in each iterations and the reconstruction is carried out in EIDORS. The PEPR method is studied with the simulated boundary data for different inhomogeneity geometries. Simulated results demonstrate that the PEPR technique improves image reconstruction precision in EIDORS and hence it can be successfully implemented to increase the reconstruction accuracy in EIT.>doi:10.5617/jeb.158 J Electr Bioimp, vol. 2, pp. 2-12, 2011

  11. Error calculations statistics in radioactive measurements

    International Nuclear Information System (INIS)

    Verdera, Silvia

    1994-01-01

    Basic approach and procedures frequently used in the practice of radioactive measurements.Statistical principles applied are part of Good radiopharmaceutical Practices and quality assurance.Concept of error, classification as systematic and random errors.Statistic fundamentals,probability theories, populations distributions, Bernoulli, Poisson,Gauss, t-test distribution,Ξ2 test, error propagation based on analysis of variance.Bibliography.z table,t-test table, Poisson index ,Ξ2 test

  12. Heuristics and Cognitive Error in Medical Imaging.

    Science.gov (United States)

    Itri, Jason N; Patel, Sohil H

    2018-05-01

    The field of cognitive science has provided important insights into mental processes underlying the interpretation of imaging examinations. Despite these insights, diagnostic error remains a major obstacle in the goal to improve quality in radiology. In this article, we describe several types of cognitive bias that lead to diagnostic errors in imaging and discuss approaches to mitigate cognitive biases and diagnostic error. Radiologists rely on heuristic principles to reduce complex tasks of assessing probabilities and predicting values into simpler judgmental operations. These mental shortcuts allow rapid problem solving based on assumptions and past experiences. Heuristics used in the interpretation of imaging studies are generally helpful but can sometimes result in cognitive biases that lead to significant errors. An understanding of the causes of cognitive biases can lead to the development of educational content and systematic improvements that mitigate errors and improve the quality of care provided by radiologists.

  13. Study of wavefront error and polarization of a side mounted infrared window

    Science.gov (United States)

    Liu, Jiaguo; Li, Lin; Hu, Xinqi; Yu, Xin

    2008-03-01

    The wavefront error and polarization of a side mounted infrared window made of ZnS are studied. The Infrared windows suffer from temperature gradient and stress during their launch process. Generally, the gradient in temperature changes the refractive index of the material whereas stress produces deformation and birefringence. In this paper, a thermal finite element analysis (FEA) of an IR window is presented. For this purpose, we employed an FEA program Ansys to obtain the time-varying temperature field. The deformation and stress of the window are derived from a structural FEA with the aerodynamic force and the temperature field previously obtained as being the loads. The deformation, temperature field, stress field, ray tracing and Jones Calculus are used to calculate the wavefront error and the change of polarization state.

  14. Social aspects of clinical errors.

    Science.gov (United States)

    Richman, Joel; Mason, Tom; Mason-Whitehead, Elizabeth; McIntosh, Annette; Mercer, Dave

    2009-08-01

    Clinical errors, whether committed by doctors, nurses or other professions allied to healthcare, remain a sensitive issue requiring open debate and policy formulation in order to reduce them. The literature suggests that the issues underpinning errors made by healthcare professionals involve concerns about patient safety, professional disclosure, apology, litigation, compensation, processes of recording and policy development to enhance quality service. Anecdotally, we are aware of narratives of minor errors, which may well have been covered up and remain officially undisclosed whilst the major errors resulting in damage and death to patients alarm both professionals and public with resultant litigation and compensation. This paper attempts to unravel some of these issues by highlighting the historical nature of clinical errors and drawing parallels to contemporary times by outlining the 'compensation culture'. We then provide an overview of what constitutes a clinical error and review the healthcare professional strategies for managing such errors.

  15. Negative refraction of inhomogeneous waves in lossy isotropic media

    International Nuclear Information System (INIS)

    Fedorov, V Yu; Nakajima, T

    2014-01-01

    We theoretically study negative refraction of inhomogeneous waves at the interface of lossy isotropic media. We obtain explicit (up to the sign) expressions for the parameters of a wave transmitted through the interface between two lossy media characterized by complex permittivity and permeability. We show that the criterion of negative refraction that requires negative permittivity and permeability can be used only in the case of a homogeneous incident wave at the interface between a lossless and lossy media. In a more general situation, when the incident wave is inhomogeneous, or both media are lossy, the criterion of negative refraction becomes dependent on an incidence angle. Most interestingly, we show that negative refraction can be realized in conventional lossy materials (such as metals) if their interfaces are properly oriented. (paper)

  16. Optical and Biometric Characteristics of Anisomyopia in Human Adults

    Science.gov (United States)

    Tian, Yibin; Tarrant, Janice; Wildsoet, Christine F.

    2011-01-01

    Purpose To investigate the role of higher order optical aberrations and thus retinal image degradation in the development of myopia, through the characterization of anisomyopia in human adults in terms of their optical and biometric characteristics. Methods The following data were collected from both eyes of fifteen young adult anisometropic myopes and sixteen isometropic myopes: subjective and objective refractive errors, corneal power and shape, monochromatic optical aberrations, anterior chamber depth, lens thickness, vitreous chamber depth, and best corrected visual acuity. Monochromatic aberrations were analyzed in terms of their higher order components, and further analyzed in terms of 31 optical quality metrics. Interocular differences for the two groups (anisomyopes vs. isomyopes) were compared and the relationship between measured ocular parameters and refractive errors also analyzed across all eyes. Results As expected, anisomyopes and isomyopes differed significantly in terms of interocular differences in vitreous chamber depth, axial length and refractive error. However, interocular differences in other optical properties showed no significant intergroup differences. Overall, higher myopia was associated with deeper anterior and vitreous chambers, higher astigmatism, more prolate corneas, and more positive spherical aberration. Other measured optical and biometric parameters were not significantly correlated with spherical refractive error, although some optical quality metrics and corneal astigmatism were significantly correlated with refractive astigmatism. Conclusions An optical cause for anisomyopia related to increased higher order aberrations is not supported by our data. Corneal shape changes and increased astigmatism in more myopic eyes may be a by-product of the increased anterior chamber growth in these eyes; likewise, the increased positive spherical aberration in more myopic eyes may be a product of myopic eye growth. PMID:21797915

  17. Application of seismic refraction tomography for subsurface imaging ...

    African Journals Online (AJOL)

    Seismic refraction tomography involves the measurement of the travel times of seismic refracted raypaths in order to define an image of seismic velocity in the intervening ground. This technique was used to estimate the depth to the fresh basement, estimate thickness of the weathered basement and to determine the ...

  18. Refractive power and biometric properties of the nonhuman primate isolated crystalline lens.

    Science.gov (United States)

    Borja, David; Manns, Fabrice; Ho, Arthur; Ziebarth, Noel M; Acosta, Ana Carolina; Arrieta-Quintera, Esdras; Augusteyn, Robert C; Parel, Jean-Marie

    2010-04-01

    Purpose. To characterize the age dependence of shape, refractive power, and refractive index of isolated lenses from nonhuman primates. Methods. Measurements were performed on ex vivo lenses from cynomolgus monkeys (cyno: n = 120; age, 2.7-14.3 years), rhesus monkeys (n = 61; age, 0.7-13.3 years), and hamadryas baboons (baboon: n = 16; age, 1.7-27.3 years). Lens thickness, diameter, and surface curvatures were measured with an optical comparator. Lens refractive power was measured with a custom optical system based on the Scheiner principle. The refractive contributions of the gradient, the surfaces, and the equivalent refractive index were calculated with optical ray-tracing software. The age dependence of the optical and biometric parameters was assessed. Results. Over the measured age range isolated lens thickness decreased (baboon: -0.04, cyno: -0.05, and rhesus: -0.06 mm/y) and equatorial diameter increased (logarithmically for the baboon and rhesus, and linearly for cyno: 0.07 mm/y). The isolated lens surfaces flattened and the corresponding refractive power from the surfaces decreased with age (-0.33, -0.48, and -0.68 D/y). The isolated lens equivalent refractive index decreased (only significant for the baboon, -0.001 D/y), and as a result the total isolated lens refractive power decreased with age (baboon: -1.26, cyno: -0.97, and rhesus: -1.76 D/y). Conclusions. The age-dependent trends in the optical and biometric properties, growth, and aging, of nonhuman primate lenses are similar to those of the pre-presbyopic human lens. As the lens ages, the decrease in refractive contributions from the gradient refractive index causes a rapid age-dependent decrease in maximally accommodated lens refractive power.

  19. First-principle calculation of refractive indices of BAlN and BGaN

    KAUST Repository

    Alqatari, Feras; Li, Kuang-Hui; Liu, Kaikai; Li, Xiaohang

    2018-01-01

    The refractive indices of BAlN and BGaN ternary alloys are being investigated using first-principle calculation. The hybrid density functional theory is applied to determine the refractive indices of different alloys. A peculiar bowing effect in the static refractive indices and crossovers of different refractive index curves are found. We speculate that the explanation to these phenomena lies in the interband transitions of electrons where each band bows at a different rate from the other. An average of these bowing effects may result in the bowing of refractive indices.

  20. First-principle calculation of refractive indices of BAlN and BGaN

    KAUST Repository

    Alqatari, Feras

    2018-03-27

    The refractive indices of BAlN and BGaN ternary alloys are being investigated using first-principle calculation. The hybrid density functional theory is applied to determine the refractive indices of different alloys. A peculiar bowing effect in the static refractive indices and crossovers of different refractive index curves are found. We speculate that the explanation to these phenomena lies in the interband transitions of electrons where each band bows at a different rate from the other. An average of these bowing effects may result in the bowing of refractive indices.

  1. A Technique for Real-Time Ionospheric Ranging Error Correction Based On Radar Dual-Frequency Detection

    Science.gov (United States)

    Lyu, Jiang-Tao; Zhou, Chen

    2017-12-01

    Ionospheric refraction is one of the principal error sources for limiting the accuracy of radar systems for space target detection. High-accuracy measurement of the ionospheric electron density along the propagation path of radar wave is the most important procedure for the ionospheric refraction correction. Traditionally, the ionospheric model and the ionospheric detection instruments, like ionosonde or GPS receivers, are employed for obtaining the electron density. However, both methods are not capable of satisfying the requirements of correction accuracy for the advanced space target radar system. In this study, we propose a novel technique for ionospheric refraction correction based on radar dual-frequency detection. Radar target range measurements at two adjacent frequencies are utilized for calculating the electron density integral exactly along the propagation path of the radar wave, which can generate accurate ionospheric range correction. The implementation of radar dual-frequency detection is validated by a P band radar located in midlatitude China. The experimental results present that the accuracy of this novel technique is more accurate than the traditional ionospheric model correction. The technique proposed in this study is very promising for the high-accuracy radar detection and tracking of objects in geospace.

  2. Infrared Spectra, Index of Refraction, and Optical Constants of Nitrile Ices Relevant to Titan's Atmosphere

    Science.gov (United States)

    Moore, Marla; Ferrante, Robert; Moore, William; Hudson, Reggie

    2010-01-01

    Spectra and optical constants of nitrite ices known or suspected to be in Titan's atmosphere are presented from 2.5 to 200 microns (4000 to 50 per cm ). These results are relevant to the ongoing modeling of Cassini CIRS observations of Titan's winter pole. Ices studied include: HCN, hydrogen cyanide; C2N2, cyanogen; CH3CN, acetonitrile; C 2H5CN, propionitrile; and HC3N, cyanoacetylene. For each of these molecules we report new measurements of the index of refraction, n, determined in both the amorphous- and crystallinephase at 670 nm. Spectra were measured and optical constants were calculated for each nitrite at a variety of temperatures including 20, 35, 50, 75, 95, and 110 K, in the amorphous- and crystalline-phase. This laboratory effort uses a dedicated FTIR spectrometer to record transmission spectra of thin-film ice samples. Laser interference is used to measure film thickness during condensation onto a transparent cold window attached to the tail section of a closed-cycle helium cryostat. Optical constants, real (n) and imaginary (k) refractive indices, are determined using Kramers-Kronig (K-K) analysis. Our calculation reproduces the complete spectrum, including all interference effects. Index of refraction measurements are made in a separate dedicated FTIR spectrometer where interference deposit fringes are measured using two 670 nm lasers at different angles to the ice substrate. A survey of these new measurements will be presented along with a discussion of their validation, errors, and application to Titan data.

  3. Refraction and eye anterior segment parameters in schizophrenic patients

    Directory of Open Access Journals (Sweden)

    Tongabay Cumurcu

    2015-06-01

    Full Text Available ABSTRACT Purpose: To evaluate the difference in terms of refractive errors and anterior segment parameters between schizophrenic patients and healthy volunteers. Methods: This study compared 70 patients (48 men who were diagnosed with schizophrenia with a control group of 60 (35 men who were similar in terms of age, gender, education, and socioeconomic level. Anterior segment examination was performed using a Scheimflug system. Axial length and lens thickness (LT were measured using optic biometry. The following tests were administered to the psychiatric patient group: Brief Psychiatric Rating Scale (BPRS, Scale for the Assessment of Negative Symptoms (SANS, and Scale for the Assessment of Positive Symptoms (SAPS. Results: Mild myopia was detected in both the schizophrenic and control groups, with no statistically significant difference (p>0.005. Corneal volume (CV, anterior chamber volume (ACV, anterior chamber depth (ACD, and central corneal thickness (CCT values were lower in the schizophrenic group, and there was a statistically significant between-group difference (p=0.026, p=0.014, p=0.048, and p=0.005, respectively. LT was greater in schizophrenics, and the difference was found to be statistically significant (p=0.006. A statistically significant negative correlation was found between SAPS and cylinder values (p=0.008. The axial eye length, cylinder value, pupil diameter, mean keratometric value, and anterior chamber angle revealed no statistically significant difference between the groups (p>0.05. Conclusion: No statistically significant difference was detected in terms of refraction disorders between schizophrenics and the healthy control group, while some differences in anterior chamber parameters were present. These results demonstrate that schizophrenics may exhibit clinical and structural differences in the eye.

  4. Extraordinary refraction and self-collimation properties of multilayer metallic-dielectric stratified structures

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Liwei, E-mail: zlwhpu@hotmail.com [School of Physics and Chemistry, Henan Polytechnic University, Jiaozuo 454000 (China); Chen, Liang [School of Physics and Chemistry, Henan Polytechnic University, Jiaozuo 454000 (China); Zhang, Zhengren [School of Science, Chongqing Jiaotong University, Chongqing 400074 (China); Wang, Wusong [Guizhou Aerospace Institute of Measuring and Testing Technology, Guiyang 550009 (China); Zhao, Yuhuan; Song, Kechao; Kang, Chaoyang [School of Physics and Chemistry, Henan Polytechnic University, Jiaozuo 454000 (China)

    2015-01-15

    The extraordinary refraction with negative or zero refraction angle of the layered metamaterial consisting of alternating dielectric and plasmonic layers is theoretically studied. It is shown that the electromagnetic properties can be tuned by the filling factor, the permittivity of the dielectric layer and the plasma frequency of the metallic layer. At different frequency, the layered structures possess different refraction properties with positive, zero or negative refraction angle. By choosing appropriate parameters, positive-to-zero-to-negative-to positive refraction at the desired frequency can be realized. At the frequency with flat equal frequency contour, self-collimation and slow light properties are also found. Such properties can be used in the performance of negative refraction, subwavelength imaging and information propagation.

  5. Rotationally asymmetric multifocal IOL implantation with and without capsular tension ring: refractive and visual outcomes and intraocular optical performance.

    Science.gov (United States)

    Alió, Jorge L; Plaza-Puche, Ana B; Piñero, David P

    2012-04-01

    To ascertain whether the refractive, visual, and intraocular optical quality outcomes of a rotationally asymmetric multifocal intraocular lens (IOL) are enhanced by the use of a capsular tension ring. Ninety consecutive eyes from 53 patients (age range: 36 to 82 years) were divided into two groups: the no ring group comprised 43 eyes implanted with the multifocal rotationally asymmetric Lentis Mplus LS-312 (Oculentis GmbH) without a capsular tension ring; and the ring group comprised 47 eyes with the same IOL with a capsular tension ring. Distance and near visual acuity and refractive outcomes were evaluated pre- and postoperatively. Contrast sensitivity, intraocular aberrations, and defocus curve were evaluated postoperatively. Significant postoperative differences between groups were found in sphere, spherical equivalent refraction, and near addition (P<.02). Regarding defocus curve, significantly better visual acuity was present in eyes with the capsular tension ring for intermediate vision conditions (P<.05). Intraocular aberrometry did not differ significantly between groups (P<.09). Refractive predictability and intermediate visual outcomes with the Lentis Mplus LS-312 IOL improved significantly when implanted in combination with a capsular tension ring. Copyright 2012, SLACK Incorporated.

  6. A variational regularization of Abel transform for GPS radio occultation

    Directory of Open Access Journals (Sweden)

    T.-K. Wee

    2018-04-01

    Full Text Available In the Global Positioning System (GPS radio occultation (RO technique, the inverse Abel transform of measured bending angle (Abel inversion, hereafter AI is the standard means of deriving the refractivity. While concise and straightforward to apply, the AI accumulates and propagates the measurement error downward. The measurement error propagation is detrimental to the refractivity in lower altitudes. In particular, it builds up negative refractivity bias in the tropical lower troposphere. An alternative to AI is the numerical inversion of the forward Abel transform, which does not incur the integration of error-possessing measurement and thus precludes the error propagation. The variational regularization (VR proposed in this study approximates the inversion of the forward Abel transform by an optimization problem in which the regularized solution describes the measurement as closely as possible within the measurement's considered accuracy. The optimization problem is then solved iteratively by means of the adjoint technique. VR is formulated with error covariance matrices, which permit a rigorous incorporation of prior information on measurement error characteristics and the solution's desired behavior into the regularization. VR holds the control variable in the measurement space to take advantage of the posterior height determination and to negate the measurement error due to the mismodeling of the refractional radius. The advantages of having the solution and the measurement in the same space are elaborated using a purposely corrupted synthetic sounding with a known true solution. The competency of VR relative to AI is validated with a large number of actual RO soundings. The comparison to nearby radiosonde observations shows that VR attains considerably smaller random and systematic errors compared to AI. A noteworthy finding is that in the heights and areas that the measurement bias is supposedly small, VR follows AI very closely in the

  7. A variational regularization of Abel transform for GPS radio occultation

    Science.gov (United States)

    Wee, Tae-Kwon

    2018-04-01

    In the Global Positioning System (GPS) radio occultation (RO) technique, the inverse Abel transform of measured bending angle (Abel inversion, hereafter AI) is the standard means of deriving the refractivity. While concise and straightforward to apply, the AI accumulates and propagates the measurement error downward. The measurement error propagation is detrimental to the refractivity in lower altitudes. In particular, it builds up negative refractivity bias in the tropical lower troposphere. An alternative to AI is the numerical inversion of the forward Abel transform, which does not incur the integration of error-possessing measurement and thus precludes the error propagation. The variational regularization (VR) proposed in this study approximates the inversion of the forward Abel transform by an optimization problem in which the regularized solution describes the measurement as closely as possible within the measurement's considered accuracy. The optimization problem is then solved iteratively by means of the adjoint technique. VR is formulated with error covariance matrices, which permit a rigorous incorporation of prior information on measurement error characteristics and the solution's desired behavior into the regularization. VR holds the control variable in the measurement space to take advantage of the posterior height determination and to negate the measurement error due to the mismodeling of the refractional radius. The advantages of having the solution and the measurement in the same space are elaborated using a purposely corrupted synthetic sounding with a known true solution. The competency of VR relative to AI is validated with a large number of actual RO soundings. The comparison to nearby radiosonde observations shows that VR attains considerably smaller random and systematic errors compared to AI. A noteworthy finding is that in the heights and areas that the measurement bias is supposedly small, VR follows AI very closely in the mean refractivity

  8. Economic impact of medication error: a systematic review.

    Science.gov (United States)

    Walsh, Elaine K; Hansen, Christina Raae; Sahm, Laura J; Kearney, Patricia M; Doherty, Edel; Bradley, Colin P

    2017-05-01

    Medication error is a significant source of morbidity and mortality among patients. Clinical and cost-effectiveness evidence are required for the implementation of quality of care interventions. Reduction of error-related cost is a key potential benefit of interventions addressing medication error. The aim of this review was to describe and quantify the economic burden associated with medication error. PubMed, Cochrane, Embase, CINAHL, EconLit, ABI/INFORM, Business Source Complete were searched. Studies published 2004-2016 assessing the economic impact of medication error were included. Cost values were expressed in Euro 2015. A narrative synthesis was performed. A total of 4572 articles were identified from database searching, and 16 were included in the review. One study met all applicable quality criteria. Fifteen studies expressed economic impact in monetary terms. Mean cost per error per study ranged from €2.58 to €111 727.08. Healthcare costs were used to measure economic impact in 15 of the included studies with one study measuring litigation costs. Four studies included costs incurred in primary care with the remaining 12 measuring hospital costs. Five studies looked at general medication error in a general population with 11 studies reporting the economic impact of an individual type of medication error or error within a specific patient population. Considerable variability existed between studies in terms of financial cost, patients, settings and errors included. Many were of poor quality. Assessment of economic impact was conducted predominantly in the hospital setting with little assessment of primary care impact. Limited parameters were used to establish economic impact. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.

  9. Refraction-contrast bone imaging using synchrotron radiation

    International Nuclear Information System (INIS)

    Mori, Koichi; Sekine, Norio; Sato, Hitoshi; Shikano, Naoto; Shimao, Daisuke; Shiwaku, Hideaki; Hyodo, Kazuyuki; Oka, Hiroshi

    2002-01-01

    The X-ray refraction-contrast imaging using synchrotron radiation with some X-ray energies is successfully performed at B120B2 of SPring-8. The refraction-contrast images of bone samples such as human dried proximal phalanx, wrist, upper cervical vertebrae and sella turcica and as mouse proximal femur using the synchrotron X-ray are always better in image contrast and resolution than those of the absorption-contrast images using the synchrotron X-ray and/or the conventional X-ray tube. There is much likeness in the image contrast and resolution of trabeculae bone in the human dried proximal phalanx between X-ray energy of 30 keV at sample-to-film distance of 1 m and those of 40, 50 keV at those of 4,5 m, respectively. High-energy refraction-contrast imaging with suitable sample-to-film distance could reduce the exposure dose in human imaging. In the refraction-contrast imaging of human wrist, upper cervcal vertebrae, sella turcica and mouse proximal femur using the synchrotron X-ray, we can obtain better image contrast and resolution to correctly extract morphological information for diagnosis corresponding to each of the clinical field than those of the absorption-contrast images. (author)

  10. The next organizational challenge: finding and addressing diagnostic error.

    Science.gov (United States)

    Graber, Mark L; Trowbridge, Robert; Myers, Jennifer S; Umscheid, Craig A; Strull, William; Kanter, Michael H

    2014-03-01

    Although health care organizations (HCOs) are intensely focused on improving the safety of health care, efforts to date have almost exclusively targeted treatment-related issues. The literature confirms that the approaches HCOs use to identify adverse medical events are not effective in finding diagnostic errors, so the initial challenge is to identify cases of diagnostic error. WHY HEALTH CARE ORGANIZATIONS NEED TO GET INVOLVED: HCOs are preoccupied with many quality- and safety-related operational and clinical issues, including performance measures. The case for paying attention to diagnostic errors, however, is based on the following four points: (1) diagnostic errors are common and harmful, (2) high-quality health care requires high-quality diagnosis, (3) diagnostic errors are costly, and (4) HCOs are well positioned to lead the way in reducing diagnostic error. FINDING DIAGNOSTIC ERRORS: Current approaches to identifying diagnostic errors, such as occurrence screens, incident reports, autopsy, and peer review, were not designed to detect diagnostic issues (or problems of omission in general) and/or rely on voluntary reporting. The realization that the existing tools are inadequate has spurred efforts to identify novel tools that could be used to discover diagnostic errors or breakdowns in the diagnostic process that are associated with errors. New approaches--Maine Medical Center's case-finding of diagnostic errors by facilitating direct reports from physicians and Kaiser Permanente's electronic health record--based reports that detect process breakdowns in the followup of abnormal findings--are described in case studies. By raising awareness and implementing targeted programs that address diagnostic error, HCOs may begin to play an important role in addressing the problem of diagnostic error.

  11. REFRACTIVE ANOMALIES OF AMBLYOPIC CHILDREN WITH AND WITHOUT STRABISMUS

    Directory of Open Access Journals (Sweden)

    Ljiljana Otašević

    2003-04-01

    Full Text Available Refractive anomalies occur when the ratio of the refraction ability and the eye length is distrurbed. Amblyopia isunderstood as dimness of vision without detectable lesions of the eye.The aim of the paper is to analyze refractive anomalies occurring in amblyopic children without of with strabismus. The cards of the children suffering from amblyopia and of five of more years of age have been singled out. The number of children obtained in that way is 243. Under special observation were bilateral and unilateral amblyopias and refractive anomalies in children both with and without strabismus. Out of 243 children there are 153 without strabismus (the majority of them reported for examination at the age of seven and 90 with strabismus (the majority of them reported at the age of five. In both the groups bilateral and unilateral amblyopia was registered so that the overall number of the observed amblyopic eyes was 369. In the children without strabismus we mostly found light amblyopia while in the froup of children with strabismus we found, in a great number, medium serious amblyopia while the presence of serious amblypia was also detected. As for refractive anomalies in both the groups of amblyopic children the most freqent were hypermetropic astigmatism and hypermetropia. Because of refractive anomalies as well as with strabismus with small angle, amblyopias are often discovered only when sharpness if vision is being checked; therefore, of great importance are regular systematic examinations of vision sharpness of younger children.

  12. [Peripheral refraction and retinal contour in children with myopia by results of refractometry and partial coherence interferometry].

    Science.gov (United States)

    Tarutta, E P; Milash, S V; Tarasova, N A; Romanova, L I; Markosian, G A; Epishina, M V

    2014-01-01

    To determine the posterior pole contour of the eye based on the relative peripheral refractive error and relative eye length. A parallel study was performed, which enrolled 38 children (76 eyes) with myopia from -1.25 to -10.82 diopters. The patients underwent peripheral refraction assessment with WR-5100K Binocular Auto Refractometer ("Grand Seiko", Japan) and partial coherence tomography with IOLMaster ("Carl Zeiss", Germany) for the relative eye length in areas located 15 and 30 degrees nasal and temporal from the central fovea along the horizontal meridian. In general, refractometry and interferometry showed high coincidence of defocus signs and values for the areas located 15 and 30 degrees nasal as well as 15 degrees temporal from the fovea. However, in 41% of patients defocus signs determined by the two methods mismatched in one or more areas. Most of the mismatch cases were mild myopia. We suppose that such a mismatch is caused by optical peculiarities of the anterior eye segment that have an impact on refractometry results.

  13. Refractive-Index Sensing with Ultrathin Plasmonic Nanotubes

    DEFF Research Database (Denmark)

    Raza, Søren; Toscano, Giuseppe; Jauho, Antti-Pekka

    2013-01-01

    We study the refractive-index sensing properties of plasmonic nanotubes with a dielectric core and ultrathin metal shell. The few nanometer thin metal shell is described by both the usual Drude model and the nonlocal hydrodynamic model to investigate the effects of nonlocality. We derive an analy......We study the refractive-index sensing properties of plasmonic nanotubes with a dielectric core and ultrathin metal shell. The few nanometer thin metal shell is described by both the usual Drude model and the nonlocal hydrodynamic model to investigate the effects of nonlocality. We derive...... an analytical expression for the extinction cross section and show how sensing of the refractive index of the surrounding medium and the figure of merit are affected by the shape and size of the nanotubes. Comparison with other localized surface plasmon resonance sensors reveals that the nanotube exhibits...

  14. Miniature interferometer for refractive index measurement in microfluidic chip

    Science.gov (United States)

    Chen, Minghui; Geiser, Martial; Truffer, Frederic; Song, Chengli

    2012-12-01

    The design and development of the miniaturized interferometer for measurement of the refractive index or concentration of sub-microliter volume aqueous solution in microfludic chip is presented. It is manifested by a successful measurement of the refractive index of sugar-water solution, by utilizing a laser diode for light source and the small robust instrumentation for practical implementation. Theoretically, the measurement principle and the feasibility of the system are analyzed. Experimental device is constructed with a diode laser, lens, two optical plate and a complementary metal oxide semiconductor (CMOS). Through measuring the positional changes of the interference fringes, the refractive index change are retrieved. A refractive index change of 10-4 is inferred from the measured image data. The entire system is approximately the size of half and a deck of cards and can operate on battery power for long time.

  15. Creating Materials with Negative Refraction Index using Topology Optimization

    DEFF Research Database (Denmark)

    Christiansen, Rasmus Ellebæk; Sigmund, Ole

    is used for regularizationand a projection step applied to obtain clean 0/1 designs. A continuation scheme is used to avoidstagnation in the optimization. Metamaterials with negative refraction index designed using this method are presented. The angular dependence of the refraction index......We apply topology optimization along with full modeling of the electromagnetic (acoustic) field to create metamaterials with negative refraction index. We believe that our approach can be used in the design of metamaterials with specific effective permittivity and permeability e.g. by adapting....... The direction of propagation for the prescribed wave is chosen to match the angle of incidence of the incoming plane wave and its position isused to select the refraction index for the slab. We introducing a continuous design field and apply The Method of Moving Asymptotes to perform the optimization. A filter...

  16. Visual and refractive outcomes of LASIK with the SCHWIND ESIRIS and WaveLight ALLEGRETTO WAVE Eye-q excimer lasers: a prospective, contralateral study.

    Science.gov (United States)

    Mearza, Ali A; Muhtaseb, Mohammed; Aslanides, Ioannis M

    2008-11-01

    To compare the safety, efficacy, and predictability of LASIK with the SCHWIND ESIRIS and WaveLight ALLEGRETTO WAVE Eye-Q excimer laser platforms. This prospective study comprised 44 eyes of 22 consecutive patients who were treated with LASIK using the Moria M2 microkeratome. One eye was treated with the SCHWIND ESIRIS laser and the fellow eye treated with the WaveLight ALLEGRETTO WAVE Eye-Q laser. All eyes operated with the SCHWIND ESIRIS were treated with standard aspheric ablation, whereas the eyes operated with the WaveLight ALLEGRETTO WAVE Eye-Q received treatment with three different ablation types according to the common practice at our clinic. Outcome measures were uncorrected visual acuity (UCVA), best spectacle-corrected visual acuity (BSCVA), manifest refraction, and proximity to target refraction at 6-month follow-up. At 6 months postoperative, mean decimal UCVA was 0.96+/-0.22 (range: 0.3 to 1.2) for ESIRIS eyes and 0.98+/-0.17 (range: 0.6 to 1.2) for ALLEGRETTO eyes (P=.57). Mean postoperative spherical equivalent refraction was -0.02+/-0.28 diopters (D) (range: -0.75 to +0.75 D) for ESIRIS eyes and 0.11+/-0.91 D (range: -1.00 to +3.88 D) for ALLEGRETTO eyes (P=.49). Of the ESIRIS eyes, 20/22 (91%) were within +/-1.00 D of target refraction and 20/22 (91%) were within +/-0.50 D of target refraction. Of the ALLEGRETTO eyes, 20/22 (91%) and 19/22 (86%) were within +/-1.00 D and +/-0.50 D, respectively, of target refraction. No patient lost > or =2 lines of BSCVA in either group. No differences were seen in safety and efficacy outcome parameters between the SCHWIND ESIRIS and WaveLight ALLEGRETTO WAVE Eye-Q excimer lasers when used according to a previously established treatment algorithm at our clinic in the treatment of refractive error.

  17. Conceptualization of Light Refraction

    Science.gov (United States)

    Sokolowski, Andrzej

    2013-01-01

    There have been a number of papers dealing quantitatively with light refraction. Yet the conceptualization of the phenomenon that sets the foundation for a more rigorous math analysis is minimized. The purpose of this paper is to fill that gap. (Contains 3 figures.)

  18. Parsimonious wave-equation travel-time inversion for refraction waves

    KAUST Repository

    Fu, Lei; Hanafy, Sherif M.; Schuster, Gerard T.

    2017-01-01

    We present a parsimonious wave-equation travel-time inversion technique for refraction waves. A dense virtual refraction dataset can be generated from just two reciprocal shot gathers for the sources at the endpoints of the survey line, with N

  19. 3D super-virtual refraction interferometry

    KAUST Repository

    Lu, Kai

    2014-08-05

    Super-virtual refraction interferometry enhances the signal-to-noise ratio of far-offset refractions. However, when applied to 3D cases, traditional 2D SVI suffers because the stationary positions of the source-receiver pairs might be any place along the recording plane, not just along a receiver line. Moreover, the effect of enhancing the SNR can be limited because of the limitations in the number of survey lines, irregular line geometries, and azimuthal range of arrivals. We have developed a 3D SVI method to overcome these problems. By integrating along the source or receiver lines, the cross-correlation or the convolution result of a trace pair with the source or receiver at the stationary position can be calculated without the requirement of knowing the stationary locations. In addition, the amplitudes of the cross-correlation and convolution results are largely strengthened by integration, which is helpful to further enhance the SNR. In this paper, both synthetic and field data examples are presented, demonstrating that the super-virtual refractions generated by our method have accurate traveltimes and much improved SNR.

  20. Error Evaluation in a Stereovision-Based 3D Reconstruction System

    Directory of Open Access Journals (Sweden)

    Kohler Sophie

    2010-01-01

    Full Text Available The work presented in this paper deals with the performance analysis of the whole 3D reconstruction process of imaged objects, specifically of the set of geometric primitives describing their outline and extracted from a pair of images knowing their associated camera models. The proposed analysis focuses on error estimation for the edge detection process, the starting step for the whole reconstruction procedure. The fitting parameters describing the geometric features composing the workpiece to be evaluated are used as quality measures to determine error bounds and finally to estimate the edge detection errors. These error estimates are then propagated up to the final 3D reconstruction step. The suggested error analysis procedure for stereovision-based reconstruction tasks further allows evaluating the quality of the 3D reconstruction. The resulting final error estimates enable lastly to state if the reconstruction results fulfill a priori defined criteria, for example, fulfill dimensional constraints including tolerance information, for vision-based quality control applications for example.

  1. Fully interferometric controllable anomalous refraction efficiency using cross modulation with plasmonic metasurfaces.

    Science.gov (United States)

    Liu, Zhaocheng; Chen, Shuqi; Li, Jianxiong; Cheng, Hua; Li, Zhancheng; Liu, Wenwei; Yu, Ping; Xia, Ji; Tian, Jianguo

    2014-12-01

    We present a method of fully interferometric, controllable anomalous refraction efficiency by introducing cross-modulated incident light based on plasmonic metasurfaces. Theoretical analyses and numerical simulations indicate that the anomalous and ordinary refracted beams generated from two opposite-helicity incident beams and following the generalized Snell's law will have a superposition for certain incident angles, and the anomalous refraction efficiency can be dynamically controlled by changing the relative phase of the incident sources. As the incident wavelength nears the resonant wavelength of the plasmonic metasurfaces, two equal-amplitude incident beams with opposite helicity can be used to control the anomalous refraction efficiency. Otherwise, two unequal-amplitude incident beams with opposite helicity can be used to fully control the anomalous refraction efficiency. This Letter may offer a further step in the development of controllable anomalous refraction.

  2. Moderating Argos location errors in animal tracking data

    Science.gov (United States)

    Douglas, David C.; Weinziert, Rolf; Davidson, Sarah C.; Kays, Roland; Wikelski, Martin; Bohrer, Gil

    2012-01-01

    1. The Argos System is used worldwide to satellite-track free-ranging animals, but location errors can range from tens of metres to hundreds of kilometres. Low-quality locations (Argos classes A, 0, B and Z) dominate animal tracking data. Standard-quality animal tracking locations (Argos classes 3, 2 and 1) have larger errors than those reported in Argos manuals.

  3. Optical bulk and surface waves with negative refraction

    International Nuclear Information System (INIS)

    Agranovich, V.M.; Shen, Y.R.; Baughman, R.H.; Zakhidov, A.A.

    2004-01-01

    In materials with negative refraction, the direction of wave propagation is opposite to the direction of the wave vector. Using an approach that characterizes the optical response of a medium totally by a generalized dielectric permittivity, ε-bar (ω,k-bar), we discuss the possibility of seeing negative refraction for optical waves in a number of nonmagnetic media. These include bulk waves in organic materials and in gyrotropic materials where additional exciton-polariton waves can have a negative group velocity. It is known that dispersion of surface waves can be engineered by tailoring a surface transition layer. We show how this effect can be used to obtain surface waves with negative refraction

  4. Refractive surgery trends and practice style changes in Germany over a 3-year period.

    Science.gov (United States)

    Schmack, Ingo; Auffarth, Gerd U; Epstein, Daniel; Holzer, Mike P

    2010-03-01

    To study the current practice styles and preferences of refractive surgeons in Germany. In February 2008, a seven-item questionnaire regarding the practice of refractive surgery was mailed to 282 members of the German Society of Intra-ocular Lens Implantation, Interventional, and Refractive Surgery (DGII) and the Commission of Refractive Surgery (KRC). Most questions were identical to our 2005 German refractive surgery survey. All data were analyzed in a masked fashion. The response rate was 42.2%. The majority (68%) of respondents reported that they perform refractive surgery in laser centers (exclusively or partially) followed by general hospitals (19.4%) and universities (12.6%). Although LASIK was the predominant type of refractive surgery performed (80.6%), other refractive procedures included refractive lens exchange (60.2%), photorefractive keratectomy (47.6%), phakic intraocular lens implants (45.6%), laser-assisted subepithelial keratectomy (36.9%), epithelial laser in situ keratomileusis (15.5%), intracorneal rings (5.8%), and limbal relaxing incisions (2.9%). The volume of refractive surgery procedures and the preferred type of excimer laser systems, microkeratomes, and diagnostic devices varied at different institutions. Most respondents performed either wavefront-guided custom ablation or wavefront-optimized ablation (63.1%) compared with conventional excimer laser correction (36.9%). Refractive surgery practice styles and preferences in Germany are comparable to trends in other European countries. Although LASIK is the most commonly performed refractive procedure, the numbers of various surface ablation techniques and refractive intraocular lens procedures are increasing. Copyright 2010, SLACK Incorporated.

  5. Approaching Error-Free Customer Satisfaction through Process Change and Feedback Systems

    Science.gov (United States)

    Berglund, Kristin M.; Ludwig, Timothy D.

    2009-01-01

    Employee-based errors result in quality defects that can often impact customer satisfaction. This study examined the effects of a process change and feedback system intervention on error rates of 3 teams of retail furniture distribution warehouse workers. Archival records of error codes were analyzed and aggregated as the measure of quality. The…

  6. Anterior segment surgery IOLs, lasers, and refractive keratoplasty

    Energy Technology Data Exchange (ETDEWEB)

    Stark, W.J.; Terry, A.C.; Maumenee, A.E.

    1987-01-01

    The contributors to this text combine their expertise to make this book available on intraocular lenses, refractive corneal surgery, and the use of the YAG laser. Included is information on; IOL power calculations; the use of the YAG laser; retinal damage by short wavelength light; reviews of corneal refractive surgery; possibilities for the medical prevention of cataracts; and more.

  7. Automated refraction is stable 1 week after uncomplicated cataract surgery

    DEFF Research Database (Denmark)

    Ostri, Christoffer; Holfort, Stig K; Fich, Marianne S

    2018-01-01

    PURPOSE: To compare automated refraction 1 week and 1 month after uncomplicated cataract surgery. METHODS: In this prospective cohort study, we recruited patients in a 2-month period and included consecutive patients scheduled for bilateral small-incision phacoemulsification cataract surgery....... The exclusion criteria were (i) corneal and/or retinal pathology that could lead to automated refraction miscalculation and (ii) surgery complications. Automated refraction was measured 1 week and 1 month after surgery. RESULTS: Ninety-five patients met the in- and exclusion criteria and completed follow......-up. The mean refractive shift in spherical equivalent was -0.02 dioptre (D) between 1 week and 1 month after surgery and not statistical significant (p = 0.78, paired t-test). The magnitude of refractive shift in either myopic or hyperopic direction was neither correlated to age, preoperative corneal...

  8. Irregular analytical errors in diagnostic testing - a novel concept.

    Science.gov (United States)

    Vogeser, Michael; Seger, Christoph

    2018-02-23

    In laboratory medicine, routine periodic analyses for internal and external quality control measurements interpreted by statistical methods are mandatory for batch clearance. Data analysis of these process-oriented measurements allows for insight into random analytical variation and systematic calibration bias over time. However, in such a setting, any individual sample is not under individual quality control. The quality control measurements act only at the batch level. Quantitative or qualitative data derived for many effects and interferences associated with an individual diagnostic sample can compromise any analyte. It is obvious that a process for a quality-control-sample-based approach of quality assurance is not sensitive to such errors. To address the potential causes and nature of such analytical interference in individual samples more systematically, we suggest the introduction of a new term called the irregular (individual) analytical error. Practically, this term can be applied in any analytical assay that is traceable to a reference measurement system. For an individual sample an irregular analytical error is defined as an inaccuracy (which is the deviation from a reference measurement procedure result) of a test result that is so high it cannot be explained by measurement uncertainty of the utilized routine assay operating within the accepted limitations of the associated process quality control measurements. The deviation can be defined as the linear combination of the process measurement uncertainty and the method bias for the reference measurement system. Such errors should be coined irregular analytical errors of the individual sample. The measurement result is compromised either by an irregular effect associated with the individual composition (matrix) of the sample or an individual single sample associated processing error in the analytical process. Currently, the availability of reference measurement procedures is still highly limited, but LC

  9. Refraction in Terms of the Deviation of the Light.

    Science.gov (United States)

    Goldberg, Fred M.

    1985-01-01

    Discusses refraction in terms of the deviation of light. Points out that in physics courses where very little mathematics is used, it might be more suitable to describe refraction entirely in terms of the deviation, rather than by introducing Snell's law. (DH)

  10. Constrained motion estimation-based error resilient coding for HEVC

    Science.gov (United States)

    Guo, Weihan; Zhang, Yongfei; Li, Bo

    2018-04-01

    Unreliable communication channels might lead to packet losses and bit errors in the videos transmitted through it, which will cause severe video quality degradation. This is even worse for HEVC since more advanced and powerful motion estimation methods are introduced to further remove the inter-frame dependency and thus improve the coding efficiency. Once a Motion Vector (MV) is lost or corrupted, it will cause distortion in the decoded frame. More importantly, due to motion compensation, the error will propagate along the motion prediction path, accumulate over time, and significantly degrade the overall video presentation quality. To address this problem, we study the problem of encoder-sider error resilient coding for HEVC and propose a constrained motion estimation scheme to mitigate the problem of error propagation to subsequent frames. The approach is achieved by cutting off MV dependencies and limiting the block regions which are predicted by temporal motion vector. The experimental results show that the proposed method can effectively suppress the error propagation caused by bit errors of motion vector and can improve the robustness of the stream in the bit error channels. When the bit error probability is 10-5, an increase of the decoded video quality (PSNR) by up to1.310dB and on average 0.762 dB can be achieved, compared to the reference HEVC.

  11. Plasmonic nanoshell functionalized etched fiber Bragg gratings for highly sensitive refractive index measurements.

    Science.gov (United States)

    Burgmeier, Jörg; Feizpour, Amin; Schade, Wolfgang; Reinhard, Björn M

    2015-02-15

    A novel fiber optical refractive index sensor based on gold nanoshells immobilized on the surface of an etched single-mode fiber including a Bragg grating is demonstrated. The nanoparticle coating induces refractive index dependent waveguide losses, because of the variation of the evanescently guided part of the light. Hence the amplitude of the Bragg reflection is highly sensitive to refractive index changes of the surrounding medium. The nanoshell functionalized fiber optical refractive index sensor works in reflectance mode, is suitable for chemical and biochemical sensing, and shows an intensity dependency of 4400% per refractive index unit in the refractive index range between 1.333 and 1.346. Furthermore, the physical length of the sensor is smaller than 3 mm with a diameter of 6 μm, and therefore offers the possibility of a localized refractive index measurement.

  12. Anomalous waves propagating at very high frequency in the atmosphere and their disturbances due to changes in refractivity profiles

    Directory of Open Access Journals (Sweden)

    Imtiaz Alam

    2018-03-01

    Full Text Available Anomalous waves propagation is severely affected due to almost always present variations in refractivity under various environmental conditions at different time, location and frequency. These conditions, representing different state of the atmosphere including e.g. foggy, rainy and cloudy etc., not only degrade the quality of the signal but sometimes completely eradicate the communication link. Such severe impact on propagation cannot be ignored by the designers of communication systems. The aim of this research is to present correlation between experimental and modelled link losses for variations in refractivity values recommended by International Telecommunication Union-Recommendations (ITU-R as well as that of standard profiles. To do so, a communication setup of 50 km over the Sea operating experimentally over a period of a year at 240 MHz is analyzed for different refractivity profiles and their impact on propagation. A median value is taken for every set of 6000 values taken from the recorded data set of more than 48 million experimental link losses. This reduces the huge data set of the experimental link losses to 8000 values only. This reduced data set of experimental and modelled link losses were correlated and investigated for different evaporation duct heights throughout the year. For the considered link, the ITU-R refractivity profile was found to perform better than the standard refractivity profile. However, the new findings as observed in this research, which may be helpful for the recommendations authorities, is the existing of evaporation duct up to 10 m height. Keywords: Parabolic equation, Link loss, Refractivity, Propagation, Troposphere, Very high frequency

  13. Refractive and diffractive neutron optics with reduced chromatic aberration

    DEFF Research Database (Denmark)

    Poulsen, Stefan Othmar; Poulsen, Henning Friis; Bentley, P.M.

    2014-01-01

    by the use of optics for focusing and imaging. Refractive and diffractive optical elements, e.g. compound refractive lenses and Fresnel zone plates, are attractive due to their low cost, and simple alignment. These optical elements, however, suffer from chromatic aberration, which limit their effectiveness...

  14. Technique for forming ITO films with a controlled refractive index

    Energy Technology Data Exchange (ETDEWEB)

    Markov, L. K., E-mail: l.markov@mail.ioffe.ru; Smirnova, I. P.; Pavluchenko, A. S.; Kukushkin, M. V.; Zakheim, D. A.; Pavlov, S. I. [Russian Academy of Sciences, Ioffe Physical–Technical Institute (Russian Federation)

    2016-07-15

    A new method for fabricating transparent conducting coatings based on indium-tin oxide (ITO) with a controlled refractive index is proposed. This method implies the successive deposition of material by electron-beam evaporation and magnetron sputtering. Sputtered coatings with different densities (and, correspondingly, different refractive indices) can be obtained by varying the ratio of the mass fractions of material deposited by different methods. As an example, films with effective refractive indices of 1.2, 1.4, and 1.7 in the wavelength range of 440–460 nm are fabricated. Two-layer ITO coatings with controlled refractive indices of the layers are also formed by the proposed method. Thus, multilayer transparent conducting coatings with desired optical parameters can be produced.

  15. Refractive index based measurements

    DEFF Research Database (Denmark)

    2014-01-01

    In a method for performing a refractive index based measurement of a property of a fluid such as chemical composition or temperature, a chirp in the local spatial frequency of interference fringes of an interference pattern is reduced by mathematical manipulation of the recorded light intensity...

  16. Anomalous waves propagating at very high frequency in the atmosphere and their disturbances due to changes in refractivity profiles

    Science.gov (United States)

    Alam, Imtiaz; Waqar, Asad; Aamir, Muhammad; Hassan, Shahzad; Shah, Syed Asim Ali

    2018-03-01

    Anomalous waves propagation is severely affected due to almost always present variations in refractivity under various environmental conditions at different time, location and frequency. These conditions, representing different state of the atmosphere including e.g. foggy, rainy and cloudy etc., not only degrade the quality of the signal but sometimes completely eradicate the communication link. Such severe impact on propagation cannot be ignored by the designers of communication systems. The aim of this research is to present correlation between experimental and modelled link losses for variations in refractivity values recommended by International Telecommunication Union-Recommendations (ITU-R) as well as that of standard profiles. To do so, a communication setup of 50 km over the Sea operating experimentally over a period of a year at 240 MHz is analyzed for different refractivity profiles and their impact on propagation. A median value is taken for every set of 6000 values taken from the recorded data set of more than 48 million experimental link losses. This reduces the huge data set of the experimental link losses to 8000 values only. This reduced data set of experimental and modelled link losses were correlated and investigated for different evaporation duct heights throughout the year. For the considered link, the ITU-R refractivity profile was found to perform better than the standard refractivity profile. However, the new findings as observed in this research, which may be helpful for the recommendations authorities, is the existing of evaporation duct up to 10 m height.

  17. On the anodic aluminium oxide refractive index of nanoporous templates

    International Nuclear Information System (INIS)

    Hierro-Rodriguez, A; Rocha-Rodrigues, P; Araujo, J P; Valdés-Bango, F; Alameda, J M; Teixeira, J M; Jorge, P A S; Santos, J L; Guerreiro, A

    2015-01-01

    In the present study, we have determined the intrinsic refractive index of anodic aluminium oxide, which is originated by the formation of nanoporous alumina templates. Different templates have been fabricated by the conventional two-step anodization procedure in oxalic acid. Their porosities were modified by chemical wet etching allowing the tuning of their effective refractive indexes (air-filled nanopores  +  anodic aluminium oxide). By standard spectroscopic light transmission measurements, the effective refractive index for each different template was extracted in the VIS–NIR region. The determination of the intrinsic anodic aluminium oxide refractive index was performed by using the Maxwell–Garnett homogenization theory. The results are coincident for all the fabricated samples. The obtained refractive index (∼1.55) is quite lower (∼22%) than the commonly used Al 2 O 3 handbook value (∼1.75), showing that the amorphous nature of the anodic oxide structure strongly conditions its optical properties. This difference is critical for the correct design and modeling of optical plasmonic metamaterials based on anodic aluminium oxide nanoporous templates. (paper)

  18. Error evaluation method for material accountancy measurement. Evaluation of random and systematic errors based on material accountancy data

    International Nuclear Information System (INIS)

    Nidaira, Kazuo

    2008-01-01

    International Target Values (ITV) shows random and systematic measurement uncertainty components as a reference for routinely achievable measurement quality in the accountancy measurement. The measurement uncertainty, called error henceforth, needs to be periodically evaluated and checked against ITV for consistency as the error varies according to measurement methods, instruments, operators, certified reference samples, frequency of calibration, and so on. In the paper an error evaluation method was developed with focuses on (1) Specifying clearly error calculation model, (2) Getting always positive random and systematic error variances, (3) Obtaining probability density distribution of an error variance and (4) Confirming the evaluation method by simulation. In addition the method was demonstrated by applying real data. (author)

  19. Generalized laws of reflection and refraction from transformation optics

    OpenAIRE

    Xu, Yadong; Yao, Kan; Chen, Huanyang

    2012-01-01

    Based on transformation optics, we introduce another set of generalized laws of reflection and refraction (differs from that of [Science 334, 333 (2011)]), through which a transformation media slab is derived as a meta-surface, producing anomalous reflection and refraction for all polarizations of incident light.

  20. Retrospective Analysis of the Post-Operative Changes in Higher-Order Aberrations: A Comparison of the WaveLight EX500 to the VISX S4 Laser in Refractive Surgery.

    Science.gov (United States)

    Reed, Donovan S; Apsey, Douglas; Steigleman, Walter; Townley, James; Caldwell, Matthew

    2017-11-01

    WaveLight EX500 laser was 0.004323, with a standard deviation of 0.02916. The mean change in RMS value for LASIK using the VISX laser was 0.00841, with a standard deviation of 0.03011. The mean change in RMS value for LASIK using the WaveLight EX500 laser was 0.0174, with a standard deviation of 0.02417. When comparing the two lasers for PRK and LASIK procedures, the p values were 0.431 and 0.295, respectively. The results of this study suggest no statistically significant difference concerning induced higher-order aberrations between the two laser platforms for either LASIK or PRK. Overall, the VISX laser did have consistently lower induced higher-order aberrations postoperatively, but this did not reach statistical significance. It is likely the statistical significance of this study was hindered by the power, given the relatively small sample size. Additional limitations of the study include its design, being a retrospective analysis, and the generalizability of the study, as the Department of Defense population may be significantly different from the typical refractive surgery population in terms of overall health and preoperative refractive error. Further investigation of visual outcomes between the two laser platforms should be investigated before determining superiority in terms of visual image and quality postoperatively. Reprint & Copyright © 2017 Association of Military Surgeons of the U.S.