WorldWideScience

Sample records for reference system undergoes

  1. Antares Reference Telescope System

    International Nuclear Information System (INIS)

    Viswanathan, V.K.; Kaprelian, E.; Swann, T.; Parker, J.; Wolfe, P.; Woodfin, G.; Knight, D.

    1983-01-01

    Antares is a 24-beam, 40-TW carbon-dioxide laser-fusion system currently nearing completion at the Los Alamos National Laboratory. The 24 beams will be focused onto a tiny target (typically 300 to 1000 μm in diameter) located approximately at the center of a 7.3-m-diameter by 9.3-m-long vacuum (10 - 6 torr) chamber. The design goal is to position the targets to within 10 μm of a selected nominal position, which may be anywhere within a fixed spherical region 1 cm in diameter. The Antares Reference Telescope System is intended to help achieve this goal for alignment and viewing of the various targets used in the laser system. The Antares Reference Telescope System consists of two similar electro-optical systems positioned in a near orthogonal manner in the target chamber area of the laser. Each of these consists of four subsystems: (1) a fixed 9X optical imaging subsystem which produces an image of the target at the vidicon; (2) a reticle projection subsystem which superimposes an image of the reticle pattern at the vidicon; (3) an adjustable front-lighting subsystem which illuminates the target; and (4) an adjustable back-lighting subsystem which also can be used to illuminate the target. The various optical, mechanical, and vidicon design considerations and trade-offs are discussed. The final system chosen (which is being built) and its current status are described in detail

  2. Expert Systems in Reference Services.

    Science.gov (United States)

    Roysdon, Christine, Ed.; White, Howard D., Ed.

    1989-01-01

    Eleven articles introduce expert systems applications in library and information science, and present design and implementation issues of system development for reference services. Topics covered include knowledge based systems, prototype development, the use of artificial intelligence to remedy current system inadequacies, and an expert system to…

  3. Korean Reference HLW Disposal System

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Heui Joo; Lee, J. Y.; Kim, S. S. (and others)

    2008-03-15

    This report outlines the results related to the development of Korean Reference Disposal System for High-level radioactive wastes. The research has been supported around for 10 years through a long-term research plan by MOST. The reference disposal method was selected via the first stage of the research during which the technical guidelines for the geological disposal of HLW were determined too. At the second stage of the research, the conceptual design of the reference disposal system was made. For this purpose the characteristics of the reference spent fuels from PWR and CANDU reactors were specified, and the material and specifications of the canisters were determined in term of structural analysis and manufacturing capability in Korea. Also, the mechanical and chemical characteristics of the domestic Ca-bentonite were analyzed in order to supply the basic design parameters of the buffer. Based on these parameters the thermal and mechanical analysis of the near-field was carried out. Thermal-Hydraulic-Mechanical behavior of the disposal system was analyzed. The reference disposal system was proposed through the second year research. At the final third stage of the research, the Korean Reference disposal System including the engineered barrier, surface facilities, and underground facilities was proposed through the performance analysis of the disposal system.

  4. Space-Time Reference Systems

    CERN Document Server

    Soffel, Michael

    2013-01-01

    The high accuracy of modern astronomical spatial-temporal reference systems has made them considerably complex. This book offers a comprehensive overview of such systems. It begins with a discussion of ‘The Problem of Time’, including recent developments in the art of clock making (e.g., optical clocks) and various time scales. The authors address  the definitions and realization of spatial coordinates by reference to remote celestial objects such as quasars. After an extensive treatment of classical equinox-based coordinates, new paradigms for setting up a celestial reference system are introduced that no longer refer to the translational and rotational motion of the Earth. The role of relativity in the definition and realization of such systems is clarified. The topics presented in this book are complemented by exercises (with solutions). The authors offer a series of files, written in Maple, a standard computer algebra system, to help readers get a feel for the various models and orders of magnitude. ...

  5. SNAP operating system reference manual

    International Nuclear Information System (INIS)

    Sabuda, J.D.; Polito, J.; Walker, J.L.; Grant, F.H. III.

    1982-03-01

    The SNAP Operating System (SOS) is a FORTRAN 77 program which provides assistance to the safeguards analyst who uses the Safeguards Automated Facility Evaluation (SAFE) and the Safeguards Network Analysis Procedure (SNAP) techniques. Features offered by SOS are a data base system for storing a library of SNAP applications, computer graphics representation of SNAP models, a computer graphics editor to develop and modify SNAP models, a SAFE-to-SNAP interface, automatic generation of SNAP input data, and a computer graphic post-processor for SNAP. The SOS Reference Manual provides detailed application information concerning SOS as well as a detailed discussion of all SOS components and their associated command input formats. SOS was developed for the US Nuclear Regulatory Commission's Office of Nuclear Regulatory Research and the US Naval Surface Weapons Center by Pritsker and Associates, Inc., under contract to Sandia National Laboratories

  6. The Spallation Neutron Source RF Reference System

    CERN Document Server

    Piller, Maurice; Crofford, Mark; Doolittle, Lawrence; Ma, Hengjie

    2005-01-01

    The Spallation Neutron Source (SNS) RF Reference System includes the master oscillator (MO), local oscillator(LO) distribution, and Reference RF distribution systems. Coherent low noise Reference RF signals provide the ability to control the phase relationships between the fields in the front-end and linear accelerator (linac) RF cavity structures. The SNS RF Reference System requirements, implementation details, and performance are discussed.

  7. Organ doses for reference pediatric and adolescent patients undergoing computed tomography estimated by Monte Carlo simulation

    International Nuclear Information System (INIS)

    Lee, Choonsik; Kim, Kwang Pyo; Long, Daniel J.; Bolch, Wesley E.

    2012-01-01

    Purpose: To establish an organ dose database for pediatric and adolescent reference individuals undergoing computed tomography (CT) examinations by using Monte Carlo simulation. The data will permit rapid estimates of organ and effective doses for patients of different age, gender, examination type, and CT scanner model. Methods: The Monte Carlo simulation model of a Siemens Sensation 16 CT scanner previously published was employed as a base CT scanner model. A set of absorbed doses for 33 organs/tissues normalized to the product of 100 mAs and CTDI vol (mGy/100 mAs mGy) was established by coupling the CT scanner model with age-dependent reference pediatric hybrid phantoms. A series of single axial scans from the top of head to the feet of the phantoms was performed at a slice thickness of 10 mm, and at tube potentials of 80, 100, and 120 kVp. Using the established CTDI vol - and 100 mAs-normalized dose matrix, organ doses for different pediatric phantoms undergoing head, chest, abdomen-pelvis, and chest-abdomen-pelvis (CAP) scans with the Siemens Sensation 16 scanner were estimated and analyzed. The results were then compared with the values obtained from three independent published methods: CT-Expo software, organ dose for abdominal CT scan derived empirically from patient abdominal circumference, and effective dose per dose-length product (DLP). Results: Organ and effective doses were calculated and normalized to 100 mAs and CTDI vol for different CT examinations. At the same technical setting, dose to the organs, which were entirely included in the CT beam coverage, were higher by from 40 to 80% for newborn phantoms compared to those of 15-year phantoms. An increase of tube potential from 80 to 120 kVp resulted in 2.5-2.9-fold greater brain dose for head scans. The results from this study were compared with three different published studies and/or techniques. First, organ doses were compared to those given by CT-Expo which revealed dose differences up to

  8. Systemic Assessment of Patients Undergoing Dental Implant ...

    African Journals Online (AJOL)

    Background: Procedure‑related and patient‑related factors influence the prognosis of dental implants to a major extent. Hence, we aimed to evaluate and analyze various systemic factors in patients receiving dental implants. Materials and Methods: Fifty‑one patients were included in the study, in which a total of 110 dental ...

  9. Genetics Home Reference: systemic scleroderma

    Science.gov (United States)

    ... Facebook Twitter Home Health Conditions Systemic scleroderma Systemic scleroderma Printable PDF Open All Close All Enable Javascript to view the expand/collapse boxes. Description Systemic scleroderma is an autoimmune disorder that affects the skin ...

  10. Dose audit for patients undergoing two common radiography examinations with digital radiology systems

    Science.gov (United States)

    İnal, Tolga; Ataç, Gökçe

    2014-01-01

    PURPOSE We aimed to determine the radiation doses delivered to patients undergoing general examinations using computed or digital radiography systems in Turkey. MATERIALS AND METHODS Radiographs of 20 patients undergoing posteroanterior chest X-ray and of 20 patients undergoing anteroposterior kidney-ureter-bladder radiography were evaluated in five X-ray rooms at four local hospitals in the Ankara region. Currently, almost all radiology departments in Turkey have switched from conventional radiography systems to computed radiography or digital radiography systems. Patient dose was measured for both systems. The results were compared with published diagnostic reference levels (DRLs) from the European Union and International Atomic Energy Agency. RESULTS The average entrance surface doses (ESDs) for chest examinations exceeded established international DRLs at two of the X-ray rooms in a hospital with computed radiography. All of the other ESD measurements were approximately equal to or below the DRLs for both examinations in all of the remaining hospitals. Improper adjustment of the exposure parameters, uncalibrated automatic exposure control systems, and failure of the technologists to choose exposure parameters properly were problems we noticed during the study. CONCLUSION This study is an initial attempt at establishing local DRL values for digital radiography systems, and will provide a benchmark so that the authorities can establish reference dose levels for diagnostic radiology in Turkey. PMID:24317331

  11. Dose audit for patients undergoing two common radiography examinations with digital radiology systems.

    Science.gov (United States)

    İnal, Tolga; Ataç, Gökçe

    2014-01-01

    We aimed to determine the radiation doses delivered to patients undergoing general examinations using computed or digital radiography systems in Turkey. Radiographs of 20 patients undergoing posteroanterior chest X-ray and of 20 patients undergoing anteroposterior kidney-ureter-bladder radiography were evaluated in five X-ray rooms at four local hospitals in the Ankara region. Currently, almost all radiology departments in Turkey have switched from conventional radiography systems to computed radiography or digital radiography systems. Patient dose was measured for both systems. The results were compared with published diagnostic reference levels (DRLs) from the European Union and International Atomic Energy Agency. The average entrance surface doses (ESDs) for chest examinations exceeded established international DRLs at two of the X-ray rooms in a hospital with computed radiography. All of the other ESD measurements were approximately equal to or below the DRLs for both examinations in all of the remaining hospitals. Improper adjustment of the exposure parameters, uncalibrated automatic exposure control systems, and failure of the technologists to choose exposure parameters properly were problems we noticed during the study. This study is an initial attempt at establishing local DRL values for digital radiography systems, and will provide a benchmark so that the authorities can establish reference dose levels for diagnostic radiology in Turkey.

  12. Study of alloy crystallization in systems undergoing peritectic transformations

    International Nuclear Information System (INIS)

    Psarev, V.I.; Kirij, V.G.; Kuznetsov, A.V.; Psareva, I.V.; Ivanov, A.L.

    1982-01-01

    Studies into Ge-Te, In-Te, Al-Mn, Sb-Zn, Sn-Au systems are carried out at melt cooling rates from 50 deg/h to 10 5 deg/h to establish regularities in stable and metastable crystallization of alloys undergoing peritectic transformations. Methods of metallographic, X-ray phase and X-ray diffraction analyses are used. Differentiation in types of peritectic transformations is made through their mechanisms under equilibrium and non-equilibrium crystallization conditions for various alloy systems. It is found out that ability to supercooling even at low or moderate cooling rates for Te-Ge and Te-In system melts can be one of the main indication of the possibility of amorphous alloy formation [ru

  13. The CEBAF fiber optic phase reference system

    International Nuclear Information System (INIS)

    Crawford, K.; Simrock, S.; Hovater, C.; Krycuk, A.

    1995-01-01

    The specified phase stability of the CEBAF RF distribution system is 2.9 degree rms per linac. Stability is achieved through the use of a temperature and pressure regulated coaxial drive line. Purpose of the fiber optic phase reference system is to monitor the relative phase at the beginning and ending of this drive line, between linacs, injector and separator to determine drift due to ambient temperature fluctuations. The system utilizes an Ortel 1310 nm single mode laser driving Sumitumo optical fiber to distribute a reference signal at 1497 MHz. Phase of this reference signal is compared to the 1427 MHz (LO) and the 70 MHz (IF) via a 360 degree phase detector. The detected information is then routed to the CEBAF control system for display with a specified resolution of ±0.2 degree over a 20 degree phase delta

  14. Positional reference system for ultraprecision machining

    Science.gov (United States)

    Arnold, J.B.; Burleson, R.R.; Pardue, R.M.

    1980-09-12

    A stable positional reference system for use in improving the cutting tool-to-part contour position in numerical controlled-multiaxis metal turning machines is provided. The reference system employs a plurality of interferometers referenced to orthogonally disposed metering bars which are substantially isolated from machine strain induced position errors for monitoring the part and tool positions relative to the metering bars. A microprocessor-based control system is employed in conjunction with the plurality of positions interferometers and part contour description data input to calculate error components for each axis of movement and output them to corresponding axis driven with appropriate scaling and error compensation. Real-time position control, operating in combination with the reference system, makes possible the positioning of the cutting points of a tool along a part locus with a substantially greater degree of accuracy than has been attained previously in the art by referencing and then monitoring only the tool motion relative to a reference position located on the machine base.

  15. Positional reference system for ultraprecision machining

    International Nuclear Information System (INIS)

    Arnold, J.B.; Burleson, R.R.; Pardue, R.M.

    1982-01-01

    A stable positional reference system for use in improving the cutting tool-to-part contour position in numerical controlledmultiaxis metal turning machines is provided. The reference system employs a plurality of interferometers referenced to orthogonally disposed metering bars which are substantially isolated from machine strain induced position errors for monitoring the part and tool positions relative to the metering bars. A microprocessor-based control system is employed in conjunction with the plurality of position interferometers and part contour description data inputs to calculate error components for each axis of movement and output them to corresponding axis drives with appropriate scaling and error compensation. Real-time position control, operating in combination with the reference system, makes possible the positioning of the cutting points of a tool along a part locus with a substantially greater degree of accuracy than has been attained previously in the art by referencing and then monitoring only the tool motion relative to a reference position located on the machine base

  16. Modcomp MAX IV System Processors reference guide

    Energy Technology Data Exchange (ETDEWEB)

    Cummings, J.

    1990-10-01

    A user almost always faces a big problem when having to learn to use a new computer system. The information necessary to use the system is often scattered throughout many different manuals. The user also faces the problem of extracting the information really needed from each manual. Very few computer vendors supply a single Users Guide or even a manual to help the new user locate the necessary manuals. Modcomp is no exception to this, Modcomp MAX IV requires that the user be familiar with the system file usage which adds to the problem. At General Atomics there is an ever increasing need for new users to learn how to use the Modcomp computers. This paper was written to provide a condensed Users Reference Guide'' for Modcomp computer users. This manual should be of value not only to new users but any users that are not Modcomp computer systems experts. This Users Reference Guide'' is intended to provided the basic information for the use of the various Modcomp System Processors necessary to, create, compile, link-edit, and catalog a program. Only the information necessary to provide the user with a basic understanding of the Systems Processors is included. This document provides enough information for the majority of programmers to use the Modcomp computers without having to refer to any other manuals. A lot of emphasis has been placed on the file description and usage for each of the System Processors. This allows the user to understand how Modcomp MAX IV does things rather than just learning the system commands.

  17. Crew Transportation System Design Reference Missions

    Science.gov (United States)

    Mango, Edward J.

    2015-01-01

    Contains summaries of potential design reference mission goals for systems to transport humans to andfrom low Earth orbit (LEO) for the Commercial Crew Program. The purpose of this document is to describe Design Reference Missions (DRMs) representative of the end-to-end Crew Transportation System (CTS) framework envisioned to successfully execute commercial crew transportation to orbital destinations. The initial CTS architecture will likely be optimized to support NASA crew and NASA-sponsored crew rotation missions to the ISS, but consideration may be given in this design phase to allow for modifications in order to accomplish other commercial missions in the future. With the exception of NASA’s mission to the ISS, the remaining commercial DRMs are notional. Any decision to design or scar the CTS for these additional non-NASA missions is completely up to the Commercial Provider. As NASA’s mission needs evolve over time, this document will be periodically updated to reflect those needs.

  18. Dose study in pediatric patients undergoing cardiac procedures in a digital system

    International Nuclear Information System (INIS)

    Ordonez Marquez, J.; Huertas Martinez, C.; Luquero Llopis, N.; Vano Carruana, E.; Corredoira, S.; Huerga Cabrerizo, C.; Plaza Aparicio, R.; Tellez-Cepeda Ruiz, M.

    2011-01-01

    In La Paz Hospital in Madrid has recently installed a biplane x-ray equipment in the Department of Pediatric Cardiology. It is a digital system equipped with two amorphous silicon detectors. There has been a characterization of the equipment prior to commissioning for clinical use. It was later followed up on the dose delivered to pediatric patients undergoing various diagnostic and therapeutic procedures. Yet the absence of reference values for interventional cardiology child dose, the values obtained were used to establish baseline dose by age group that will serve as initial references and allow our radiation dose compared with those of other centers and check that the skin dose are in most cases below the thresholds for deterministic effects.

  19. Systemic scleroderma diagnosed after undergoing radiation therapy for breast cancer

    International Nuclear Information System (INIS)

    Sasaki, Tetsuo; Kakei, Masae

    1994-01-01

    A case of systemic scleroderma in which the symptoms became prominent after undergoing radiation therapy for breast cancer is reported. A 68-year-old woman, who had undergone a radical mastectomy for breast carcinoma at the age of 63 and thereafter received radiotherapy at 65, 66 and 67 years of age, visited our clinic complaining of skin sclerosis and Raynaud's phenomenon which she had noticed since the age of 65. The physical examination revealed not only postirradiation fibrosis and pigmentation, but also edematous sclerosis and the pigmentation of her extremities, as well as short frenulum of the tongue and digital pitting scars. She demonstrated serum anti-topoisomerase I antibodies, esophageal dysfunction and lung fibrosis. The histopathology of the forearm skin showed edema of the upper dermis as well as increased and homogenized collagen bundles in the middle and lower dermis. Since similar cases have been reported, it is considerable that radiation therapy may have thus worsened the lesions of scleroderma in this patient as well. (author)

  20. Systemic scleroderma diagnosed after undergoing radiation therapy for breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Sasaki, Tetsuo; Kakei, Masae (Yokohama City Univ. (Japan). Faculty of Medicine)

    1994-10-01

    A case of systemic scleroderma in which the symptoms became prominent after undergoing radiation therapy for breast cancer is reported. A 68-year-old woman, who had undergone a radical mastectomy for breast carcinoma at the age of 63 and thereafter received radiotherapy at 65, 66 and 67 years of age, visited our clinic complaining of skin sclerosis and Raynaud's phenomenon which she had noticed since the age of 65. The physical examination revealed not only postirradiation fibrosis and pigmentation, but also edematous sclerosis and the pigmentation of her extremities, as well as short frenulum of the tongue and digital pitting scars. She demonstrated serum anti-topoisomerase I antibodies, esophageal dysfunction and lung fibrosis. The histopathology of the forearm skin showed edema of the upper dermis as well as increased and homogenized collagen bundles in the middle and lower dermis. Since similar cases have been reported, it is considerable that radiation therapy may have thus worsened the lesions of scleroderma in this patient as well. (author).

  1. Reference dosimeter system of the IAEA

    International Nuclear Information System (INIS)

    Mehta, Kishor; Girzikowsky, Reinhard

    1995-01-01

    Quality assurance programmes must be in operation at radiation facilities to satisfy national and international Standards. Since dosimetry has a vital function in these QA programmes, it is imperative that the dosimetry systems in use at these facilities are well calibrated with a traceability to a Primary Standard Dosimetry Laboratory. As a service to the Member States, the International Atomic Energy Agency operates the International Dose Assurance Service (IDAS) to assist in this process. The transfer standard dosimetry system that is used for this service is based on ESR spectrometry. The paper describes the activities undertaken at the IAEA Dosimetry Laboratory to establish the QA programme for its reference dosimetry system. There are four key elements of such a programme: quality assurance manual; calibration that is traceable to a Primary Standard Dosimetry Laboratory; a clear and detailed statement of uncertainty in the dose measurement; and, periodic quality audit. (Author)

  2. Reference dosimeter system of the iaea

    Science.gov (United States)

    Mehta, Kishor; Girzikowsky, Reinhard

    1995-09-01

    Quality assurance programmes must be in operation at radiation processing facilities to satisfy national and international Standards. Since dosimetry has a vital function in these QA programmes, it is imperative that the dosimetry systems in use at these facilities are well calibrated with a traceability to a Primary Standard Dosimetry Laboratory. As a service to the Member States, the International Atomic Energy Agency operates the International Dose Assurance Service (IDAS) to assist in this process. The transfer standard dosimetry system that is used for this service is based on ESR spectrometry. The paper describes the activities undertaken at the IAEA Dosimetry Laboratory to establish the QA programme for its reference dosimetry system. There are four key elements of such a programme: quality assurance manual; calibration that is traceable to a Primary Standard Dosimetry Laboratory; a clear and detailed statement of uncertainty in the dose measurement; and, periodic quality audit.

  3. Reference dosimeter system of the IAEA

    International Nuclear Information System (INIS)

    Mehta, K.; Girzikowsky, R.

    1995-01-01

    Quality assurance programmes must be in operation at radiation processing facilities to satisfy national and international standards. Since dosimetry has a vital function in these QA programmes, it is imperative that the dosimetry systems in use at these facilities are well calibrated with a traceability to a Primary Standard Dosimetry Laboratory. As a service to the Member States, the International Atomic Energy Agency operates the International Dose Assurance Service (IDAS) to assist in this process. The transfer standard dosimetry system that is used for this service is based on ESR spectrometry. The paper describes the activities undertaken at the IAEA Dosimetry Laboratory to establish the QA programme for its reference dosimetry system. There are four key elements of such a programme: quality assurance manual; calibration that is traceable to a Primary Standard Dosimetry Laboratory; a clear and detailed statement of uncertainty in the dose measurement; and, periodic quality audit. (author)

  4. Hazardous Solvent Substitution Data System reference manual

    International Nuclear Information System (INIS)

    Branham-Haar, K.A.; Twitchell, K.E.

    1993-07-01

    Concern for the environment, in addition to Federal regulation, mandate the replacement of hazardous solvents with safer cleaning agents. Manufacturers are working to produce these replacement solvents. As these products are developed, potential users need to be informed of their availability. To promote the use of these new products instead of traditional solvents, the Idaho National Engineering Laboratory (INEL) has developed the Hazardous Solvent Substitution Data System (HSSDS). The HSSDS provides a comprehensive system of information on alternatives to hazardous solvents and related subjects, and it makes that information available to solvent users, industrial hygienists, and process engineers. The HSSDS uses TOPIC reg-sign, a text retrieval system produced by Verity, Inc., to allow a user to search for information on a particular subject. TOPIC reg-sign produces a listing of the retrieved documents and allows the use to examine the documents individually and to use the information contained in them. This reference manual does not replace the comprehensive TOPIC reg-sign user documentation (available from Verity, Inc.), or the HSSDS Tutorial (available from the INEL). The purpose of this reference manual is to provide enough instruction on TOPIC reg-sign so the user may begin accessing the data contained in the HSSDS

  5. Global Reference Tables for Management Information Systems

    Data.gov (United States)

    Social Security Administration — This database is a collection of reference tables that store common information used throughout SSA. These tables standardize code structures and code usage of SSA...

  6. Global Reference Tables for Production Systems

    Data.gov (United States)

    Social Security Administration — This database is a collection of reference tables that store common information used throughout SSA. These tables standardized code structures and code usage of SSA...

  7. Exercise may reduce depression but not anxiety in self-referred cancer patients undergoing chemotherapy. Post-hoc analysis of data from the 'Body & Cancer' trial

    DEFF Research Database (Denmark)

    Midtgaard, Julie; Stage, Maria; Møller, Tom

    2011-01-01

    Abstract Background. The diagnosis and treatment of cancer may cause clinically significant and persistent psychological morbidity. The objective of this study was to determine the short-term effect of a six week exercise intervention on anxiety and depression in cancer patients undergoing.......021). Conclusion. Anti-depressant effects could be caused by exercise in self-referred cancer patients undergoing chemotherapy. Dedicated trials and follow-up studies are needed to clarify the optimal duration and content of exercise interventions to meet the needs of clinically depressive or anxious patients....... chemotherapy (The 'Body & Cancer' trial). Methods. Two hundred and nine self-referred patients (52 males, 157 females, mean age 47 years) were randomised into an intervention group and a waiting-list control group. Anxiety and depression was measured by the Hospital Anxiety and Depression Scale. Results...

  8. Outcomes in Diabetic Patients Undergoing Orbital Atherectomy System.

    Science.gov (United States)

    Lee, Michael S; Shlofmitz, Evan; Nguyen, Heajung; Shlofmitz, Richard A

    2016-10-01

    We evaluated the angiographic and clinical outcomes of orbital atherectomy to treat severely calcified coronary lesions in diabetic and non-diabetic patients. Diabetics have increased risk for death, myocardial infarction, and target vessel revascularization after percutaneous coronary intervention. Severely calcified coronary lesions are associated with increased cardiac events. Orbital atherectomy facilitates stent delivery and optimizes stent expansion by modifying severely calcified plaque. Outcomes in diabetic patients who undergo orbital atherectomy have not been reported. Our retrospective multicenter registry included 458 consecutive real-world patients with severely calcified coronary arteries who underwent orbital atherectomy. The primary safety endpoint was the rate of major adverse cardiac and cerebrovascular events at 30 days. Diabetics represented 42.1% (193/458) of the entire cohort. The primary endpoint was similar in diabetics and non-diabetics (1.0% vs. 3.0%%, P = 0.20), as were 30-day rates of death (0.5% vs. 1.9%, P = 0.41), myocardial infarction (0.5% vs. 1.5%, P = 0.40), target vessel revascularization (0% vs. 0%, P = 1), and stroke (0% vs. 0.4%, P > 0.9). Angiographic complications and stent thrombosis rate were low and did not differ between the 2 groups. Diabetics represented a sizeable portion of patients who underwent orbital atherectomy. Diabetics who had severely calcified coronary arteries and underwent orbital atherectomy had low event rates that were similar to non-diabetics. Orbital atherectomy appears to be a viable treatment strategy for diabetic patients. Randomized trials with longer-term follow-up are needed to determine the ideal treatment strategy for diabetics. © 2016, Wiley Periodicals, Inc.

  9. Indicators of collapse in systems undergoing unsustainable growth.

    Science.gov (United States)

    Ridolfi, Luca; D'Odorico, Paolo; Laio, Francesco

    2015-02-01

    Unsustainable growth is typical of systems that rely on a finite pool of non-renewable resources that are tapped until they are depleted. The decrease in resource availability eventually leads these systems to a decline. Here we investigate the dynamics of systems that exhibit unsustainable growth and are prone to a collapse to an alternative ("degraded") state. For these systems the possible imminent occurrence of a collapse is difficult to avert because they keep growing as they approach the transition point. It is therefore important to identify some early warning signs that can be used to predict whether the system is approaching a critical and likely irreversible transition to an undesired and degraded state. This study evaluates whether existing theories of precursors of phase transitions based on the critical slowing down phenomenon are applicable as leading indicators of state shift in unsustainable growth dynamics. It is found that such indicators fail to serve as reliable early warning signs of the system's collapse.

  10. Genetics Home Reference: systemic lupus erythematosus

    Science.gov (United States)

    ... Twitter Home Health Conditions Systemic lupus erythematosus Systemic lupus erythematosus Printable PDF Open All Close All Enable Javascript to view the expand/collapse boxes. Description Systemic lupus erythematosus (SLE) is a chronic disease that causes inflammation ...

  11. Material control system simulator program reference manual

    Energy Technology Data Exchange (ETDEWEB)

    Hollstien, R.B.

    1978-01-24

    A description is presented of a Material Control System Simulator (MCSS) program for determination of material accounting uncertainty and system response to particular adversary action sequences that constitute plausible material diversion attempts. The program is intended for use in situations where randomness, uncertainty, or interaction of adversary actions and material control system components make it difficult to assess safeguards effectiveness against particular material diversion attempts. Although MCSS may be used independently in the design or analysis of material handling and processing systems, it has been tailored toward the determination of material accountability and the response of material control systems to adversary action sequences.

  12. Material control system simulator program reference manual

    International Nuclear Information System (INIS)

    Hollstien, R.B.

    1978-01-01

    A description is presented of a Material Control System Simulator (MCSS) program for determination of material accounting uncertainty and system response to particular adversary action sequences that constitute plausible material diversion attempts. The program is intended for use in situations where randomness, uncertainty, or interaction of adversary actions and material control system components make it difficult to assess safeguards effectiveness against particular material diversion attempts. Although MCSS may be used independently in the design or analysis of material handling and processing systems, it has been tailored toward the determination of material accountability and the response of material control systems to adversary action sequences

  13. Behavioral Reference Model for Pervasive Healthcare Systems.

    Science.gov (United States)

    Tahmasbi, Arezoo; Adabi, Sahar; Rezaee, Ali

    2016-12-01

    The emergence of mobile healthcare systems is an important outcome of application of pervasive computing concepts for medical care purposes. These systems provide the facilities and infrastructure required for automatic and ubiquitous sharing of medical information. Healthcare systems have a dynamic structure and configuration, therefore having an architecture is essential for future development of these systems. The need for increased response rate, problem limited storage, accelerated processing and etc. the tendency toward creating a new generation of healthcare system architecture highlight the need for further focus on cloud-based solutions for transfer data and data processing challenges. Integrity and reliability of healthcare systems are of critical importance, as even the slightest error may put the patients' lives in danger; therefore acquiring a behavioral model for these systems and developing the tools required to model their behaviors are of significant importance. The high-level designs may contain some flaws, therefor the system must be fully examined for different scenarios and conditions. This paper presents a software architecture for development of healthcare systems based on pervasive computing concepts, and then models the behavior of described system. A set of solutions are then proposed to improve the design's qualitative characteristics including, availability, interoperability and performance.

  14. Mobile User Objective Systems (MUOS) Reference Implementation Laboratory (MRIL)

    Data.gov (United States)

    Federal Laboratory Consortium — The Mobile User Objective Systems (MUOS) Reference Implementation Laboratory (MRIL) performs verification and validation testing of various MUOS terminals. MRIL also...

  15. Mounting system for optical frequency reference cavities

    Science.gov (United States)

    Notcutt, Mark (Inventor); Hall, John L. (Inventor); Ma, Long-Sheng (Inventor)

    2008-01-01

    A technique for reducing the vibration sensitivity of laser-stabilizing optical reference cavities is based upon an improved design and mounting method for the cavity, wherein the cavity is mounted vertically. It is suspended at one plane, around the spacer cylinder, equidistant from the mirror ends of the cavity. The suspension element is a collar of an extremely low thermal expansion coefficient material, which surrounds the spacer cylinder and contacts it uniformly. Once the collar has been properly located, it is cemented in place so that the spacer cylinder is uniformly supported and does not have to be squeezed at all. The collar also includes a number of cavities partially bored into its lower flat surface, around the axial bore. These cavities are support points, into which mounting base pins will be inserted. Hence the collar is supported at a minimum of three points.

  16. Astronaut Neil A. Armstrong Undergoes Communications Systems Final Check

    Science.gov (United States)

    1969-01-01

    Dunned in his space suit, mission commander Neil A. Armstrong does a final check of his communications system before before the boarding of the Apollo 11 mission. Launched via a Saturn V launch vehicle, the first manned lunar mission launched from the Kennedy Space Center, Florida on July 16, 1969 and safely returned to Earth on July 24, 1969. The Saturn V vehicle was developed by the Marshall Space Flight Center (MSFC) under the direction of Dr. Wernher von Braun. The 3-man crew aboard the flight consisted of astronauts Armstrong; Michael Collins, Command Module (CM) pilot; and Edwin E. Aldrin, Jr., Lunar Module (LM) Pilot. Armstrong was the first human to ever stand on the lunar surface, followed by Edwin (Buzz) Aldrin. Meanwhile, astronaut Collins piloted the CM in a parking orbit around the Moon. During a 2½ hour surface exploration, the crew collected 47 pounds of lunar surface material which was returned to Earth for analysis. With the success of Apollo 11, the national objective to land men on the Moon and return them safely to Earth had been accomplished.

  17. Robot operating system (ROS) the complete reference

    CERN Document Server

    The objective of this book is to provide the reader with a comprehensive coverage on the Robot Operating Systems (ROS) and latest related systems, which is currently considered as the main development framework for robotics applications. The book includes twenty-seven chapters organized into eight parts. Part 1 presents the basics and foundations of ROS. In Part 2, four chapters deal with navigation, motion and planning. Part 3 provides four examples of service and experimental robots. Part 4 deals with real-world deployment of applications. Part 5 presents signal-processing tools for perception and sensing. Part 6 provides software engineering methodologies to design complex software with ROS. Simulations frameworks are presented in Part 7. Finally, Part 8 presents advanced tools and frameworks for ROS including multi-master extension, network introspection, controllers and cognitive systems. This book will be a valuable companion for ROS users and developers to learn more ROS capabilities and features.   ...

  18. weHelp: A Reference Architecture for Social Recommender Systems.

    Science.gov (United States)

    Sheth, Swapneel; Arora, Nipun; Murphy, Christian; Kaiser, Gail

    2010-01-01

    Recommender systems have become increasingly popular. Most of the research on recommender systems has focused on recommendation algorithms. There has been relatively little research, however, in the area of generalized system architectures for recommendation systems. In this paper, we introduce weHelp : a reference architecture for social recommender systems - systems where recommendations are derived automatically from the aggregate of logged activities conducted by the system's users. Our architecture is designed to be application and domain agnostic. We feel that a good reference architecture will make designing a recommendation system easier; in particular, weHelp aims to provide a practical design template to help developers design their own well-modularized systems.

  19. Developing a Frame of Reference for understanding configuration systems

    DEFF Research Database (Denmark)

    Ladeby, Klaes Rohde; Edwards, Kasper

    2008-01-01

    This paper uses the theory of technical systems to develop a frame of reference of product configuration systems. Following a definition of the configuration task, product model and product configuration system the theory of technical systems are presented. Configuration systems are then related...

  20. Changes in T-cell count in patients undergoing radiotherapy. With particular reference to preoperative irradiation for gastric carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Makino, K; Sato, S [Tokyo Medical Coll. (Japan)

    1980-01-01

    To know changes in immunological competence of T-cells induced by radiotherapy, T-cells in peripheral blood of patients who underwent radiotherapy were observed before, during, and 6 months after the irradiation. The subjects were 69 patients having malignant tumors including 20 with gastric cancer, 15 with breast cancer, and 9 with colon cancer. 200 rad of an exposure dose was irradiated for successive 5 to 6 days. A total of exposure doses ranged from 2,000 to 10,000 rad. T-cell count decreased markedly until exposure doses reached 3,000 rad, but its decrease was mild after exposure doses were over 3,000 rad. T-cell count decreased slightly in patients whose head and neck were irradiated, but it decreased markedly in patients whose thorax and abdomen were irradiated. Therefore, it was thought that there was a relationship between exposed sites and the decrease in T-cell count. T-cell count decreased markedly when irradiation field was wide. The smaller exposure doses were, the earlier the recovery of T-cell were. T-cells irradiated with over 7,000 rad did not recover within 6 months after the irradiation. The recovery of T-cells in patients with gastric cancer who did not undergo gastrectomy was markedly worse than that in patients who had gastrectomy. Patterns of changes in T-cell count were divided into 4 (ascending curve, U-type curve, flat curve, and descending curve), and prognosis of patients were discussed. There was a clear difference in prognosis of patients among four patterns.

  1. On the invariance of world time reference system

    International Nuclear Information System (INIS)

    Asanov, G.S.

    1978-01-01

    A universal reference system is studied. It is shown that time differentiation acquires an invariant meaning in the covariant theory of a curved space-time. All the principal covariant equations of the Einstein gravitational field theory can be interpreted successively relative to a universal reference system, whose base congruence is the S-congruence. The Lorentz calibration conditions determine the base tetrades of the universal reference system with an accuracy to rigid spatial rotations with constant coefficients. The use of rigid tetrades eliminates the ambiguity in the interpretation of the value of the energy momentum of a gravitational field

  2. Employment and Professional Outcomes in 803 Patients Undergoing Bariatric Surgery in a French Reference Center for Obesity

    Directory of Open Access Journals (Sweden)

    Q Durand-Moreau

    2015-04-01

    Full Text Available Background: Very few studies have been performed on small populations about the links between employment and bariatric surgery. Objective: To determine if rates of employment are increased among patients who have undergone bariatric surgery, to assess their post-operative health consequences (post-prandial weakness, diarrhea, and patients' ability to maintain post-operative advice (ie, 30 minutes of daily physical activity, 6 small meals daily compared to non-employed post-surgical patients. Methods: This cross-sectional study was performed in the Regional Reference Centre for Obesity, which is a partnership between the University Hospital and a clinic in Angers, France during 2012 using a self-administrated questionnaire completed by patients hospitalized for post-operative follow-ups after bariatric surgery. Issues investigated were their professional situation before and after the surgery, compliancy to post-operative advice, and any postoperative side effects. Results: Employment rates were 64.4% before and 64.7% after the surgery (p=0.94. Of these, 30.6% maintained 30 minutes of daily physical activity vs. 41.0% of non-workers (p=0.02. 50.5% of employed patients and 57.3% of non-workers maintained 6 small meals a day after surgery (p=0.09. 8% of working patients reported post-prandial weaknesses and 8% reported diarrhea that caused problems at work. Conclusion: Employment rate remained stable after surgery. Having a job seemed to be an obstacle to managing 30 minutes of daily exercise, especially among women, but not maintaining 6 small meals a day. Therefore, working environment needs to be assessed to improve job quality and retention for patients who have undergone bariatric surgery.

  3. A Reference Architecture for Network-Centric Information Systems

    National Research Council Canada - National Science Library

    Renner, Scott; Schaefer, Ronald

    2003-01-01

    This paper presents the "C2 Enterprise Reference Architecture" (C2ERA), which is a new technical concept of operations for building information systems better suited to the Network-Centric Warfare (NCW) environment...

  4. An Estimator for Attitude and Heading Reference Systems Based on Virtual Horizontal Reference

    DEFF Research Database (Denmark)

    Wang, Yunlong; Soltani, Mohsen; Hussain, Dil muhammed Akbar

    2016-01-01

    makes it possible to correct the output of roll and pitch of the attitude estimator in the situations without accelerometer measurements, which cannot be achieved by the conventional nonlinear attitude estimator. The performance of VHR is tested both in simulation and hardware environment to validate......The output of the attitude determination systems suffers from large errors in case of accelerometer malfunctions. In this paper, an attitude estimator, based on Virtual Horizontal Reference (VHR), is designed for an Attitude Heading and Reference System (AHRS) to cope with this problem. The VHR...... their estimation performance. Moreover, the hardware test results are compared with that of a high-precision commercial AHRS to verify the estimation results. The implemented algorithm has shown high accuracy of attitude estimation that makes the system suitable for many applications....

  5. Calculated organ doses using Monte Carlo simulations in a reference male phantom undergoing HDR brachytherapy applied to localized prostate carcinoma

    International Nuclear Information System (INIS)

    Candela-Juan, Cristian; Perez-Calatayud, Jose; Ballester, Facundo; Rivard, Mark J.

    2013-01-01

    Purpose: The aim of this study was to obtain equivalent doses in radiosensitive organs (aside from the bladder and rectum) when applying high-dose-rate (HDR) brachytherapy to a localized prostate carcinoma using 60 Co or 192 Ir sources. These data are compared with results in a water phantom and with expected values in an infinite water medium. A comparison with reported values from proton therapy and intensity-modulated radiation therapy (IMRT) is also provided. Methods: Monte Carlo simulations in Geant4 were performed using a voxelized phantom described in International Commission on Radiological Protection (ICRP) Publication 110, which reproduces masses and shapes from an adult reference man defined in ICRP Publication 89. Point sources of 60 Co or 192 Ir with photon energy spectra corresponding to those exiting their capsules were placed in the center of the prostate, and equivalent doses per clinical absorbed dose in this target organ were obtained in several radiosensitive organs. Values were corrected to account for clinical circumstances with the source located at various positions with differing dwell times throughout the prostate. This was repeated for a homogeneous water phantom. Results: For the nearest organs considered (bladder, rectum, testes, small intestine, and colon), equivalent doses given by 60 Co source were smaller (8%–19%) than from 192 Ir. However, as the distance increases, the more penetrating gamma rays produced by 60 Co deliver higher organ equivalent doses. The overall result is that effective dose per clinical absorbed dose from a 60 Co source (11.1 mSv/Gy) is lower than from a 192 Ir source (13.2 mSv/Gy). On the other hand, equivalent doses were the same in the tissue and the homogeneous water phantom for those soft tissues closer to the prostate than about 30 cm. As the distance increased, the differences of photoelectric effect in water and soft tissue, and appearance of other materials such as air, bone, or lungs, produced

  6. Discrete Model Reference Adaptive Control System for Automatic Profiling Machine

    Directory of Open Access Journals (Sweden)

    Peng Song

    2012-01-01

    Full Text Available Automatic profiling machine is a movement system that has a high degree of parameter variation and high frequency of transient process, and it requires an accurate control in time. In this paper, the discrete model reference adaptive control system of automatic profiling machine is discussed. Firstly, the model of automatic profiling machine is presented according to the parameters of DC motor. Then the design of the discrete model reference adaptive control is proposed, and the control rules are proven. The results of simulation show that adaptive control system has favorable dynamic performances.

  7. Analysis of the Reference Systems of Modern Selenographic Systems

    Science.gov (United States)

    Nefedyev, Yuri; Petrova, Natalia; Andreev, Alexey; Demina, Natalya

    2016-07-01

    In this work analysis of the reference systems of modern selenographic systems was made. The center of the Moon's mass position relative to its center of figure was determined from the data of "Clementine" and "Kaguya" missions and "ULCN" and "KSC-1162" catalogues. The knowledge of the Moon's center of mass position relative to its center of figure is important for researches of the lunar origin, structure and evolution and in terms of precision solutions circumlunar navigation tasks. At the present this task is the most relevant and demanded for cosmic lunar missions.The expansions by spherical harmonics N=5 degree and order of the lunar function h (λ, β) using the package ASNI USTU were executed. Module of the expansion of the local area to surfaces to full sphere was used. The parameters of cosmic missions are given for comparison (SAI; Bills, Ferrari). The normalized coefficients from expansions for eight sources of hypsometric information are obtained: "Clementine" (N=40), "KSC-1162" (N=5), "Kiev" (N=5), "SAI" (N=10; Chuikova (1975)), "Bills, Ferrari", "Kaguya" (Selena, Japan mission), "ULCN" (The Unified Lunar Control Network 2005). The displacements of the lunar center of figure relative to the lunar center of the mass were defined from equations (Chuikova (1975)): Δ ξ = C_{11} √{3}, Δ η= S_{11} √{3}, Δ ζ = C_{10} √{3}, where ξ is the axis directed towards the Earth, η is equatorial axis directed perpendicularly to ξ , ζ is rotation axis of the Moon, C_{11} , S_{11} , C_{10} are the normalized amplitudes of the harmonics of the first order expansion of the relief. After that we considered: - mathematical models in the form of expansions in spherical functions - methods for estimating the model parameters; - information technology data processing. As a model describing the behavior of the relief on the lunar sphere is used the expansion of the height in a series of spherical harmonics (Sagitov (1979)) in the form of a regression model

  8. An N+3 Technology Level Reference Propulsion System

    Science.gov (United States)

    Jones, Scott M.; Haller, William J.; Tong, Michael To-Hing

    2017-01-01

    An N+3 technology level engine, suitable as a propulsion system for an advanced single-aisle transport, was developed as a reference cycle for use in technology assessment and decision-making efforts. This reference engine serves three main purposes: it provides thermodynamic quantities at each major engine station, it provides overall propulsion system performance data for vehicle designers to use in their analyses, and it can be used for comparison against other proposed N+3 technology-level propulsion systems on an equal basis. This reference cycle is meant to represent the expected capability of gas turbine engines in the N+3 timeframe given reasonable extrapolations of technology improvements and the ability to take full advantage of those improvements.

  9. Properties of gravi-inertial systems of reference

    International Nuclear Information System (INIS)

    Dozmorov, I.M.

    1977-01-01

    A number of papers of the author have been summarized devoted to gravi-inertial systems of reference in which the following problems are solved: a) analogs of inertial systems of reference (ISR), gravi-ISR, have been introduced into the general relativity the ory (GRT); b) using transformations between such ISR as symmetry transformation, obtained by variational methods are values with clear physical sense; c) using the gravi-ISR basis as the zero level of the deformation reading, the theory of elasticity in GRT has been constructed and someof its applications considered. The results are compared with those of other authors

  10. Immune genes undergo more adaptive evolution than non-immune system genes in Daphnia pulex

    Directory of Open Access Journals (Sweden)

    McTaggart Seanna J

    2012-05-01

    Full Text Available Abstract Background Understanding which parts of the genome have been most influenced by adaptive evolution remains an unsolved puzzle. Some evidence suggests that selection has the greatest impact on regions of the genome that interact with other evolving genomes, including loci that are involved in host-parasite co-evolutionary processes. In this study, we used a population genetic approach to test this hypothesis by comparing DNA sequences of 30 putative immune system genes in the crustacean Daphnia pulex with 24 non-immune system genes. Results In support of the hypothesis, results from a multilocus extension of the McDonald-Kreitman (MK test indicate that immune system genes as a class have experienced more adaptive evolution than non-immune system genes. However, not all immune system genes show evidence of adaptive evolution. Additionally, we apply single locus MK tests and calculate population genetic parameters at all loci in order to characterize the mode of selection (directional versus balancing in the genes that show the greatest deviation from neutral evolution. Conclusions Our data are consistent with the hypothesis that immune system genes undergo more adaptive evolution than non-immune system genes, possibly as a result of host-parasite arms races. The results of these analyses highlight several candidate loci undergoing adaptive evolution that could be targeted in future studies.

  11. The MADE reference information model for interoperable pervasive telemedicine systems

    NARCIS (Netherlands)

    Fung, L.S.N.; Jones, Valerie M.; Hermens, Hermanus J.

    2017-01-01

    Objectives: The main objective is to develop and validate a reference information model (RIM) to support semantic interoperability of pervasive telemedicine systems. The RIM is one component within a larger, computer-interpretable "MADE language" developed by the authors in the context of the

  12. Digital Receiver Design for Transmitted Reference Ultra-Wideband Systems

    NARCIS (Netherlands)

    Wang, Y.; Leus, G.; Van der Veen, A.J.

    2009-01-01

    A complete detection, channel estimation, synchronization, and equalization scheme for a transmitted reference (TR) ultra-wideband (UWB) system is proposed in this paper. The scheme is based on a data model which admits a moderate data rate and takes both the interframe interference (IFI) and the

  13. Standard Relativistic Reference Systems and the IAU Framework

    Science.gov (United States)

    Soffel, Michael H.

    2009-05-01

    The classical post-Newtonian (PN) framework is formulated in one single reference system. In a series of papers Damour, Soffel and Xu laid the foundations for a new improved PN framework dealing with the celestial mechanical problem of N gravitationally interacting rotating bodies of arbitrary shape and the problem of astronomical reference systems. In the DSX-framework a total of N+1 reference systems with corresponding coordinates is introduced in the N-body problem: a global one covering the entire model manifold where the translational equations of motion are formulated and one local system attached to each of the N bodies that is co-moving with the body under consideration. In each of these systems the metric tensor is assumed to be of a special form determined by two potentials: a scalar and a vector potential. Theorems are given for the transformations between local and global coordinates and metric potentials. In each of the local systems outside the local body the metric potentials are expressed in terms of Blanchet-Damour mass- and spin-multipole moments. The talk first introduces the original DSX formalism and then concentrates on IAU resolutions related with it. Finally, the formalism is extended to include also effects from the cosmic expansion. The influence of the Hubble expansion on the dynamics of the solar system is explicitly discussed in some detail.

  14. Reference clock parameters for digital communications systems applications

    Science.gov (United States)

    Kartaschoff, P.

    1981-01-01

    The basic parameters relevant to the design of network timing systems describe the random and systematic time departures of the system elements, i.e., master (or reference) clocks, transmission links, and other clocks controlled over the links. The quantitative relations between these parameters were established and illustrated by means of numerical examples based on available measured data. The examples were limited to a simple PLL control system but the analysis can eventually be applied to more sophisticated systems at the cost of increased computational effort.

  15. Preoperative renin-angiotensin system inhibitors protect renal function in aging patients undergoing cardiac surgery.

    Science.gov (United States)

    Barodka, Viachaslau; Silvestry, Scott; Zhao, Ning; Jiao, Xiangyin; Whellan, David J; Diehl, James; Sun, Jian-Zhong

    2011-05-15

    Renal failure (RF) represents a major postoperative complication for elderly patients undergoing cardiac surgery. This observational cohort study examines effects of preoperative use of renin-angiotensin system (RAS) inhibitors on postoperative renal failure in aging patients undergoing cardiac surgery. We retrospectively analyzed a cohort of 1287 patients who underwent cardiac surgery at this institution (2003-2007). The patients included were ≥65 years old, scheduled for elective cardiac surgery, and without preexisting RF (defined by the criteria of the Society of Thoracic Surgeons as described in Method). Of all patients evaluated, 346 patients met the inclusion criteria and were divided into two groups: using (n = 122) or not using (n = 224) preoperative RAS inhibitors. A comparison of the two groups showed no significant differences in baseline parameters, including creatinine clearance, body mass index, history of diabetes and smoking, preoperative medicines (except that more patients with RAS inhibitors had a history of hypertension or congestive heart failure, fewer RAS inhibitor patients had chronic lung disease), in intraoperative perfusion and aortic cross-clamp time, and in postoperative complications and 30-d mortality. Multivariate logistic regression analysis demonstrated, however, that preoperative RAS inhibitors significantly and independently reduced the incidence of postoperative RF in the patients undergoing cardiac surgery compared with those not taking RAS inhibitors: 1.6% versus 7.6%, yielding an odds ratio of 0.19 (95 % CI 0.04-0.84, P = 0.029). Preoperative RAS inhibitors may have significant renoprotective effects for aging patients undergoing elective cardiac surgery. Copyright © 2011 Elsevier Inc. All rights reserved.

  16. A reference model for space data system interconnection services

    Science.gov (United States)

    Pietras, John; Theis, Gerhard

    1993-01-01

    The widespread adoption of standard packet-based data communication protocols and services for spaceflight missions provides the foundation for other standard space data handling services. These space data handling services can be defined as increasingly sophisticated processing of data or information received from lower-level services, using a layering approach made famous in the International Organization for Standardization (ISO) Open System Interconnection Reference Model (OSI-RM). The Space Data System Interconnection Reference Model (SDSI-RM) incorporates the conventions of the OSIRM to provide a framework within which a complete set of space data handling services can be defined. The use of the SDSI-RM is illustrated through its application to data handling services and protocols that have been defined by, or are under consideration by, the Consultative Committee for Space Data Systems (CCSDS).

  17. Astronomical relativistic reference systems with multipolar expansion: the global one

    International Nuclear Information System (INIS)

    Xie Yi

    2014-01-01

    With the rapid development of techniques for astronomical observations, the precision of measurements has been significantly increasing. Theories describing astronomical relativistic reference systems, which are the foundation for processing and interpreting these data now and in the future, may require extensions to satisfy the needs of these trends. Besides building a framework compatible with alternative theories of gravity and the pursuit of higher order post-Newtonian approximation, it will also be necessary to make the first order post-Newtonian multipole moments of celestial bodies be explicitly expressed in the astronomical relativistic reference systems. This will bring some convenience into modeling the observations and experiments and make it easier to distinguish different contributions in measurements. As a first step, the global solar system reference system is expressed as a multipolar expansion and the post-Newtonian mass and spin moments are shown explicitly in the metric which describes the coordinates of the system. The full expression of the global metric is given. (research papers)

  18. Performance evaluation of the Antares Reference Telescope System

    International Nuclear Information System (INIS)

    Parker, J.R.; Woodfin, G.L.; Viswanathan, V.K.

    1985-01-01

    The Antares Reference Telescope System is a complicated electro-optical-mechanical system whose main purpose is to enable positioning of targets used in the Antares Laser System to within 10 μm of a selected nominal position. To date, it has been used successfully to position targets ranging in size from 300 μm to 2 mm. The system consists of two electro-optical systems positioned in a nearly orthogonal manner. This ''cross telescope'' configuration facilitates accurate positioning in three planes. The results obtained so far in resolution and positioning of targets using this system are discussed. It is shown that a resolution of 200 lp/mm and a positioning precision of 25 μm can be obtained

  19. On Chinese National Continuous Operating Reference Station System of GNSS

    Directory of Open Access Journals (Sweden)

    CHEN Junyong

    2007-11-01

    Full Text Available Objective: Global navigation satellite system (GNSS Continuous Operating Reference Station (CORS System can maintain a accurate, 3D, geocentric and dynamic reference coordinate frame in the corresponding area, can provide positioning and navigation service. It can also serve for the meteorology, geodynamics, earthquake monitoring and Location Based services (LBS etc in the same area. Until now, our country can’t provide a facing National CORS System serving for every profession and trade, and the national sharing platform of CORS System resources has not been established. So this paper discusses some valuable insight how to construct the National CORS System in China. Method: Constructing goal、Service object、CORS distribution、CORS geographic、geology and communication environment and other factors, are major considerations for the Constructing the National CORS System. Moreover, constructing GNSS CORS is more specific, mainly from four aspects, namely site-selection、civil construction、security measures and equipment-selection for consideration. Outcome: The project of the Constructing Global navigation satellite system (GNSS Continuous Operating Reference Station (CORS System in china is put forward, and is discussed from goal、principle、project and other for construction. Some meaning thought how to construct the National CORS System is submitted Conclusion: The Global navigation satellite system (GNSS Continuous Operating Reference Station (CORS System in china is the lack of a unified planning and design in the national level. So far, the national CORS system serving all walks of life has not been provided, and the national sharing platform of CORS System resources has not been established The primary mission of the Global navigation satellite system (GNSS Continuous Operating Reference Station (CORS System in china is as follows: using data set of GNSS and receiving, transport, process, integration, transmit information and

  20. Four Reference Models for Transparency Requirements in Information Systems

    OpenAIRE

    Hosseini, Mahmoud; Shahri, Alimohammad; Phalp, Keith T.; Ali, Ra

    2017-01-01

    Transparency is a key emerging requirement in modern businesses and their information systems. Transparency refers to the information which flows amongst stakeholders for the purpose of informed decision-making and taking the right action. Transparency is generally associated with positive connotations such as trust and accountability. However, it has been shown that it could have adverse effects such as information overload and affecting decisions objectiveness. This calls for systematic app...

  1. MATHEMATICAL MODEL OF TRIAXIAL MULTIMODE ATTITUDE AND HEADING REFERENCE SYSTEM

    Directory of Open Access Journals (Sweden)

    Olha Sushchenko

    2017-07-01

    Full Text Available Purpose: The paper deals with the mathematical description of the gimballed attitude and heading reference systems, which can be applied in design of strategic precision navigation systems. The main goal is to created mathematical description taking into consideration the necessity to use different navigations operating modes of this class of navigation systems. To provide the high accuracy the indirect control is used when the position of the gimballed platform is controlled by signals of gyroscopic devices, which are corrected using accelerometer’s signals. Methods: To solve the given problem the methods of the classical theoretical mechanics, gyro theory, and inertial navigation are used. Results: The full mathematical model of the gimballed attitude and heading reference system is derived including descriptions of different operating modes. The mathematical models of the system Expressions for control and correction moments in the different modes are represented. The simulation results are given. Conclusions: The represented results prove efficiency of the proposed models. Developed mathematical models can be useful for design of navigation systems of the wide class of moving vehicles.

  2. A novel risk classification system for 30-day mortality in children undergoing surgery

    Science.gov (United States)

    Walter, Arianne I.; Jones, Tamekia L.; Huang, Eunice Y.; Davis, Robert L.

    2018-01-01

    A simple, objective and accurate way of grouping children undergoing surgery into clinically relevant risk groups is needed. The purpose of this study, is to develop and validate a preoperative risk classification system for postsurgical 30-day mortality for children undergoing a wide variety of operations. The National Surgical Quality Improvement Project-Pediatric participant use file data for calendar years 2012–2014 was analyzed to determine preoperative variables most associated with death within 30 days of operation (D30). Risk groups were created using classification tree analysis based on these preoperative variables. The resulting risk groups were validated using 2015 data, and applied to neonates and higher risk CPT codes to determine validity in high-risk subpopulations. A five-level risk classification was found to be most accurate. The preoperative need for ventilation, oxygen support, inotropic support, sepsis, the need for emergent surgery and a do not resuscitate order defined non-overlapping groups with observed rates of D30 that vary from 0.075% (Very Low Risk) to 38.6% (Very High Risk). When CPT codes where death was never observed are eliminated or when the system is applied to neonates, the groupings remained predictive of death in an ordinal manner. PMID:29351327

  3. Nuclear thermal rocket workshop reference system Rover/NERVA

    International Nuclear Information System (INIS)

    Borowski, S.K.

    1991-01-01

    The Rover/NERVA engine system is to be used as a reference, against which each of the other concepts presented in the workshop will be compared. The following topics are reviewed: the operational characteristics of the nuclear thermal rocket (NTR); the accomplishments of the Rover/NERVA programs; and performance characteristics of the NERVA-type systems for both Mars and lunar mission applications. Also, the issues of ground testing, NTR safety, NASA's nuclear propulsion project plans, and NTR development cost estimates are briefly discussed

  4. From the LHC Reference Database to the Powering Interlock System

    CERN Document Server

    Dehavay, C; Schmidt, R; Veyrunes, E; Zerlauth, M

    2003-01-01

    The protection of the magnet powering system for the Large Hadron Collider (LHC) currently being built at CERN is a major challenge due to the unprecedented complexity of the accelerator. The Powering Interlock System of the LHC will have to manage more than 1600 DC circuits for magnet powering, different in their structure, complexity and importance to the accelerator. For the coherent description of such complex system, a Reference Database as unique source of the parameters of the electrical circuits has been developed. The information, introduced via a generic circuit description language, is first used for installing the accelerator and making all electrical connections. The data is then used for tests and commissioning. During operation, the Powering Interlock System manages all critical functions. It consists of 36 PLC based controllers dis tributed around the machine and requires a flexible and transparent way of configuration, since each controller manages different numbers and types of electrical ci...

  5. Testing and reference model analysis of FTTH system

    Science.gov (United States)

    Feng, Xiancheng; Cui, Wanlong; Chen, Ying

    2009-08-01

    With rapid development of Internet and broadband access network, the technologies of xDSL, FTTx+LAN , WLAN have more applications, new network service emerges in endless stream, especially the increase of network game, meeting TV, video on demand, etc. FTTH supports all present and future service with enormous bandwidth, including traditional telecommunication service, traditional data service and traditional TV service, and the future digital TV and VOD. With huge bandwidth of FTTH, it wins the final solution of broadband network, becomes the final goal of development of optical access network.. Fiber to the Home (FTTH) will be the goal of telecommunications cable broadband access. In accordance with the development trend of telecommunication services, to enhance the capacity of integrated access network, to achieve triple-play (voice, data, image), based on the existing optical Fiber to the curb (FTTC), Fiber To The Zone (FTTZ), Fiber to the Building (FTTB) user optical cable network, the optical fiber can extend to the FTTH system of end-user by using EPON technology. The article first introduced the basic components of FTTH system; and then explain the reference model and reference point for testing of the FTTH system; Finally, by testing connection diagram, the testing process, expected results, primarily analyze SNI Interface Testing, PON interface testing, Ethernet performance testing, UNI interface testing, Ethernet functional testing, PON functional testing, equipment functional testing, telephone functional testing, operational support capability testing and so on testing of FTTH system. ...

  6. Activity Management System user reference manual. Revision 1

    International Nuclear Information System (INIS)

    Gates, T.A.; Burdick, M.B.

    1994-01-01

    The Activity Management System (AMS) was developed in response to the need for a simple-to-use, low-cost, user interface system for collecting and logging Hanford Waste Vitrification Plant Project (HWVP) activities. This system needed to run on user workstations and provide common user access to a database stored on a local network file server. Most important, users wanted a system that provided a management tool that supported their individual process for completing activities. Existing system treated the performer as a tool of the system. All AMS data is maintained in encrypted format. Users can feel confident that any activities they have entered into the database are private and that, as the originator, they retain sole control over who can see them. Once entered into the AMS database, the activities cannot be accessed by anyone other than the originator, the designated agent, or by authorized viewers who have been explicitly granted the right to look at specific activities by the originator. This user guide is intended to assist new AMS users in learning how to use the application and, after the initial learning process, will serve as an ongoing reference for experienced users in performing infrequently used functions. Online help screens provide reference to some of the key information in this manual. Additional help screens, encompassing all the applicable material in this manual, will be incorporated into future AMS revisions. A third, and most important, source of help is the AMS administrator(s). This guide describes the initial production version of AMS, which has been designated Revision 1.0

  7. Reference reactor module for NASA's lunar surface fission power system

    International Nuclear Information System (INIS)

    Poston, David I.; Kapernick, Richard J.; Dixon, David D.; Werner, James; Qualls, Louis; Radel, Ross

    2009-01-01

    Surface fission power systems on the Moon and Mars may provide the first US application of fission reactor technology in space since 1965. The Affordable Fission Surface Power System (AFSPS) study was completed by NASA/DOE to determine the cost of a modest performance, low-technical risk surface power system. The AFSPS concept is now being further developed within the Fission Surface Power (FSP) Project, which is a near-term technology program to demonstrate system-level TRL-6 by 2013. This paper describes the reference FSP reactor module concept, which is designed to provide a net power of 40 kWe for 8 years on the lunar surface; note, the system has been designed with technologies that are fully compatible with a Martian surface application. The reactor concept uses stainless-steel based. UO 2 -fueled, pumped-NaK fission reactor coupled to free-piston Stirling converters. The reactor shielding approach utilizes both in-situ and launched shielding to keep the dose to astronauts much lower than the natural background radiation on the lunar surface. The ultimate goal of this work is to provide a 'workhorse' power system that NASA can utilize in near-term and future Lunar and Martian mission architectures, with the eventual capability to evolve to very high power, low mass systems, for either surface, deep space, and/or orbital missions.

  8. Reference material systems: a sourcebook for material assessment

    Energy Technology Data Exchange (ETDEWEB)

    Bhagat, N. (ed.)

    1976-12-01

    A reference set of data related to material systems and a framework for carrying out the material technologies assessment are presented. While the bulk of renewables have been considered in this report, the nonrenewable materials dealt with here include structural materials only, such as steel, aluminum, cement and concrete, and bricks. The complete data set is supposed to include material flows, energy requirements, capital and labor inputs, and environmental effects for each process that a resource must go through to become a useful material for an end use. Although effort has been made to obtain as much information as possible, considerable gaps in data, apparent throughout this report, could not be avoided. A new material technology can be evaluated by substituting that technology for appropriate elements of the reference materials system and calculating the net change in material resource, energy, capital and labor requirements, and environmental impacts. This combination of information thus serves as a means of evaluating the potential benefits to be gained by research in various material technologies.

  9. Scalar material reference systems and loop quantum gravity

    International Nuclear Information System (INIS)

    Giesel, K; Thiemann, T

    2015-01-01

    In the past, the possibility to employ (scalar) material reference systems in order to describe classical and quantum gravity directly in terms of gauge invariant (Dirac) observables has been emphasized frequently. This idea has been picked up more recently in loop quantum gravity with the aim to perform a reduced phase space quantization of the theory, thus possibly avoiding problems with the (Dirac) operator constraint quantization method for a constrained system. In this work, we review the models that have been studied on the classical and/or the quantum level and parametrize the space of theories considered so far. We then describe the quantum theory of a model that, to the best of our knowledge, has only been considered classically so far. This model could arguably be called the optimal one in this class of models considered as it displays the simplest possible true Hamiltonian, while at the same time reducing all constraints of general relativity. (paper)

  10. Data Link Test and Analysis System/ATCRBS Transponder Test System Technical Reference

    Science.gov (United States)

    1990-05-01

    This document references material for personnel using or making software changes : to the Data Link Test and Analysis System (DATAS) for Air Traffic Control Radar : Beacon System (ATCRBS) transponder testing and data collection. This is one of : a se...

  11. Development of Information System for Patients with Cleft Lip and Palate undergoing Operation.

    Science.gov (United States)

    Augsornwan, Darawan; Pattangtanang, Pantamanas; Surakunprapha, Palakorn

    2015-08-01

    Srinagarind Hospital has 150-200 patients with cleft lip and palate each year. When patients are admitted to hospital for surgery patients and family feel they are in a crisis of life, they feel fear anxiety and need to know about how to take care of wound, they worry if patient will feel pain, how to feed patients and many things about patients. Information is very important for patients/family to prevent complications and help their decision process, decrease parents stress and encourage better co-operation. To develop information system for patients with cleft lip-palate undergoing operation. This is an action research divided into 3 phases. Phase 1 Situation review: in this phase we interview, nursing care observation, and review nursing documents about the information giving. Phase 2 Develop information system: focus groups, for discussion about what nurses can do to develop the system to give information to patients/parents. Phase 3 evaluation: by interviewing 61 parents using the structure questionnaire. 100 percent of patients/parents received information but some items were not received. Patients/parents satisfaction was 94.9 percent, no complications. The information system development provides optimal care for patients and family with cleft lip and palate, but needs to improve some techniques or tools to give more information and evaluate further the nursing outcome after.

  12. The influence of health care policies and health care system distrust on willingness to undergo genetic testing.

    Science.gov (United States)

    Armstrong, Katrina; Putt, Mary; Halbert, Chanita Hughes; Grande, David; Schwartz, Jerome Sanford; Liao, Kaijun; Marcus, Noora; Demeter, Mirar Bristol; Shea, Judy

    2012-05-01

    As the potential role of genetic testing in disease prevention and management grows, so does concern about differences in uptake of genetic testing across social and racial groups. Characteristics of how genetic tests are delivered may influence willingness to undergo testing and, if they affect population subgroups differently, alter disparities in testing. Conjoint analysis study of the effect of 3 characteristics of genetic test delivery (ie, attributes) on willingness to undergo genetic testing for cancer risk. Data were collected using a random digit dialing survey of 128 African American and 209 white individuals living in the United States. Measures included conjoint scenarios, the Revised Health Care System Distrust Scale (including the values and competence subscales), health insurance coverage, and sociodemographic characteristics. The 3 attributes studied were disclosure of test results to the health insurer, provision of the test by a specialist or primary care doctor, and race-specific or race-neutral marketing. In adjusted analyses, disclosure of test results to insurers, having to get the test from a specialist, and race-specific marketing were all inversely associated with willingness to undergo the genetic test, with the greatest effect for the disclosure attribute. Racial differences in willingness to undergo testing were not statistically significant (P=0.07) and the effect of the attributes on willingness to undergo testing did not vary by patient race. However, the decrease in willingness to undergo testing with insurance disclosure was greater among individuals with high values distrust (P=0.03), and the decrease in willingness to undergo testing from specialist access was smaller among individuals with high competence distrust (P=0.03). Several potentially modifiable characteristics of how genetic tests are delivered are associated with willingness to undergo testing. The effect of 2 of these characteristics vary according to the level of

  13. Enhanced electricity system analysis for decision making - A reference book

    International Nuclear Information System (INIS)

    2000-01-01

    The objective of electricity system analysis in support of decision making is to provide comparative assessment results upon which relevant policy choices between alternative technology options and supply strategies can be based. This reference book offers analysts, planners and decision makers documented information on enhanced approaches to electricity system analysis, that can assist in achieving this objective. The book describes the main elements of comprehensive electricity system analysis and outlines an advanced integrated analysis and decision making framework for the electric power sector. Emphasis is placed on mechanisms for building consensus between interested and affected parties, and on aspects of planning that go beyond the traditional economic optimisation approach. The scope and contents of the book cover the topics to be addressed in decision making for the power sector and the process of integrating economic, social, health and environmental aspects in the comparative assessment of alternative options and strategies. The book describes and discusses overall frameworks, processes and state of the art methods and techniques available to analysts and planners for carrying out comparative assessment studies, in order to provide sound information to decision makers. This reference book is published as part of a series of technical reports and documents prepared in the framework of the inter-agency joint project (DECADES) on databases and methodologies for comparative assessment of different energy sources for electricity generation. The overall objective of the DECADES project is to enhance capabilities for incorporating economic, social, health and environmental issues in the comparative assessment of electricity generation options and strategies in the process of decision making for the power sector. The project, established in 1992, is carried out jointly by the European Commission (EC), the Economic and Social Commission for Asia and the Pacific

  14. Realization of a reference system for the generation radon 222

    International Nuclear Information System (INIS)

    Guelin, M.

    1990-11-01

    After some general considerations on radon and its calibration techniques, the methods and technologies developed in order to realize a reference system for the generation of radon 222 are presented. Two original patented techniques have been developed. The former technique deals with the realization of radon 222 solid sources from radium 226 deposit on acrylic fibres. This new technology offers the advantage of very quickly obtaining a constant emission rate near to 100%. The latter technique deals with the standard measurement of radon 222 volumic activity via gamma spectrometry of its short-lived daughters. This new procedure is the only one allowing to relate this measure to gaseous standards. An aeraulic/ventilation circuit makes it possible to calibrate the radon measurement instrumentation within a wide volumic activity range from to 4 to 4 000 Bq/m 3

  15. Dosimetric methodology and reference system for diagnostic level X radiation

    International Nuclear Information System (INIS)

    Potiens, Maria da Penha Albuquerque

    1999-01-01

    Several methodologies for the calibration of diagnostic radiology instruments were developed and established at the Calibration Laboratory of IPEN. These established radiation qualities are recommended by international standards. The methods may be used in the calibration procedures of survey meters used in radiation protection measurements (scattered radiation), instruments used in direct beams (attenuated and non attenuated beams) and quality control instruments. A reference system was proposed using two identical ionization chambers developed at IPEN. They differ only by the collecting electrode material, one of aluminium and the other of graphite. The different energetic dependence of the chamber's response provided a ratio related to the tube potential. The variation of only 0.28%, from 14.3 to 111 keV, on the energetic dependence of the graphite electrode chamber, provided the possibility of air kerma rate determination in the studied radiation beams. (author)

  16. Modification of reference temperature program in reactor regulating system

    Energy Technology Data Exchange (ETDEWEB)

    Yu, Sung Sik; Lee, Byung Jin; Kim, Se Chang; Cheong, Jong Sik [Korea Power Engineering Company, Inc., Seoul (Korea, Republic of); Kim, Ji In; Doo, Jin Yong [Korea Electric Power Cooperation, Yonggwang (Korea, Republic of)

    1999-12-31

    In Yonggwang nuclear units 3 and 4 currently under commercial operation, the cold temperature was very close to the technical specification limit of 298 deg C during initial startup testing, which was caused by the higher-than-expected reactor coolant system flow. Accordingly, the reference temperature (Tref) program needed to be revised to allow more flexibility for plant operations. In this study, the method of a specific test performed at Yonggwang nuclear unit 4 to revise the Tref program was described and the test results were discussed. In addition, the modified Tref program was evaluated on its potential impacts on system performance and safety. The methods of changing the Tref program and the associated pressurizer level setpoint program were also explained. Finally, for Ulchin nuclear unit 3 and 4 currently under initial startup testing, the effects of reactor coolant system flow rate on the coolant temperature were evaluated from the thermal hydraulic standpoint and an optimum Tref program was recommended. 6 refs., 4 figs., 2 tabs. (Author)

  17. Modification of reference temperature program in reactor regulating system

    Energy Technology Data Exchange (ETDEWEB)

    Yu, Sung Sik; Lee, Byung Jin; Kim, Se Chang; Cheong, Jong Sik [Korea Power Engineering Company, Inc., Seoul (Korea, Republic of); Kim, Ji In; Doo, Jin Yong [Korea Electric Power Cooperation, Yonggwang (Korea, Republic of)

    1998-12-31

    In Yonggwang nuclear units 3 and 4 currently under commercial operation, the cold temperature was very close to the technical specification limit of 298 deg C during initial startup testing, which was caused by the higher-than-expected reactor coolant system flow. Accordingly, the reference temperature (Tref) program needed to be revised to allow more flexibility for plant operations. In this study, the method of a specific test performed at Yonggwang nuclear unit 4 to revise the Tref program was described and the test results were discussed. In addition, the modified Tref program was evaluated on its potential impacts on system performance and safety. The methods of changing the Tref program and the associated pressurizer level setpoint program were also explained. Finally, for Ulchin nuclear unit 3 and 4 currently under initial startup testing, the effects of reactor coolant system flow rate on the coolant temperature were evaluated from the thermal hydraulic standpoint and an optimum Tref program was recommended. 6 refs., 4 figs., 2 tabs. (Author)

  18. Overview of external reference pricing systems in Europe.

    Science.gov (United States)

    Rémuzat, Cécile; Urbinati, Duccio; Mzoughi, Olfa; El Hammi, Emna; Belgaied, Wael; Toumi, Mondher

    2015-01-01

    External reference pricing (ERP) is a price regulation tool widely used by policy makers in the European Union (EU) Member States (MS) to contain drug cost, although in theory, it may contribute to modulate prices up and down. The objective of this article was to summarise and discuss the main findings of part of a large project conducted for the European Commission ('External reference pricing of medicinal products: simulation-based considerations for cross-country coordination'; see www.ec.europa.eu/health/healthcare/docs/erp_reimbursement_medicinal_products_en.pdf) that aimed to provide an overview of ERP systems, both on processes and potential issues in 31 European countries (28 EU MS, Iceland, Norway, and Switzerland). A systematic structured literature review was conducted to identify and characterise the use of ERP in the selected countries, to describe its impact on the prices of pharmaceuticals, and to discuss the possible cross-country coordination issues in EU MS. This research was complemented with a consultation of competent authorities' and international organisations' representatives to address the main issues or uncertainties identified through the literature review. All selected countries applied ERP, except the United Kingdom and Sweden. Twenty-three countries used ERP as the main systematic criterion for pricing. In the majority of European countries, ERP was based on legislated pricing rules with different levels of accuracy. ERP was applied either for all marketed drugs or for specific categories of medicines; it was mainly used for publicly reimbursed medicines. The number of reference countries included in the basket varied from 1 to 31. There was a great variation in the calculation methods used to compute the price; 15 countries used the average price, 7 countries used the lowest price, and 7 countries used other calculation methods. Reported limitations of ERP application included the lack of reliable sources of price information, price

  19. Neural network-based model reference adaptive control system.

    Science.gov (United States)

    Patino, H D; Liu, D

    2000-01-01

    In this paper, an approach to model reference adaptive control based on neural networks is proposed and analyzed for a class of first-order continuous-time nonlinear dynamical systems. The controller structure can employ either a radial basis function network or a feedforward neural network to compensate adaptively the nonlinearities in the plant. A stable controller-parameter adjustment mechanism, which is determined using the Lyapunov theory, is constructed using a sigma-modification-type updating law. The evaluation of control error in terms of the neural network learning error is performed. That is, the control error converges asymptotically to a neighborhood of zero, whose size is evaluated and depends on the approximation error of the neural network. In the design and analysis of neural network-based control systems, it is important to take into account the neural network learning error and its influence on the control error of the plant. Simulation results showing the feasibility and performance of the proposed approach are given.

  20. Memory systems interaction in the pigeon: working and reference memory.

    Science.gov (United States)

    Roberts, William A; Strang, Caroline; Macpherson, Krista

    2015-04-01

    Pigeons' performance on a working memory task, symbolic delayed matching-to-sample, was used to examine the interaction between working memory and reference memory. Reference memory was established by training pigeons to discriminate between the comparison cues used in delayed matching as S+ and S- stimuli. Delayed matching retention tests then measured accuracy when working and reference memory were congruent and incongruent. In 4 experiments, it was shown that the interaction between working and reference memory is reciprocal: Strengthening either type of memory leads to a decrease in the influence of the other type of memory. A process dissociation procedure analysis of the data from Experiment 4 showed independence of working and reference memory, and a model of working memory and reference memory interaction was shown to predict the findings reported in the 4 experiments. (PsycINFO Database Record (c) 2015 APA, all rights reserved).

  1. A Modernized National Spatial Reference System in 2022: Focus on the Caribbean Terrestrial Reference Frame

    Science.gov (United States)

    Roman, D. R.

    2017-12-01

    In 2022, the National Geodetic Survey will replace all three NAD 83 reference frames the four new terrestrial reference frames. Each frame will be named after a tectonic plate (North American, Pacific, Caribbean and Mariana) and each will be related to the IGS frame through three Euler Pole parameters (EPPs). This talk will focus on practical application in the Caribbean region. A working group is being re-established for development of the North American region and will likely also result in analysis of the Pacific region as well. Both of these regions are adequately covered with existing CORS sites to model the EPPs. The Mariana region currently lacks sufficient coverage, but a separate project is underway to collect additional information to help in defining EPPs for that region at a later date. The Caribbean region has existing robust coverage through UNAVCO's COCONet and other data sets, but these require further analysis. This discussion will focus on practical examination of Caribbean sites to establish candidates for determining the Caribbean frame EPPs as well as an examination of any remaining velocities that might inform a model of the remaining velocities within that frame (Intra-Frame Velocity Model). NGS has a vested interest in defining such a model to meet obligations to U.S. citizens in Puerto Rico and the U.S. Virgin Islands. Beyond this, NGS aims to collaborate with other countries in the region through efforts with SIRGAS and UN-GGIM-Americas for a more acceptable regional model to serve everyone's needs.

  2. Referring to IAEA system to improve Chinese standards system on nuclear and radiation safety

    International Nuclear Information System (INIS)

    Shang Zhaorong; Wang Wenhai

    2010-01-01

    Referring to the standards system of IAEA, to build and improve the Chinese standards system of nuclear and radiation safety is a long term infrastructure work and an assurance to keep sustainable development of nuclear industry and nuclear technology application in China. The paper analyses the current main problem, and gives some suggestions on developing and improving the system. (authors)

  3. Hepatic Steatosis in Morbidly Obese Patients Undergoing Gastric Bypass Surgery: Assessment With Open-System 1H-MR Spectroscopy

    NARCIS (Netherlands)

    van Werven, Jochem R.; Schreuder, Tim C. M. A.; Aarts, Edo O.; Nederveen, Aart J.; Meijer, Jos W. R.; Berends, Frits J.; Janssen, Ignace M. C.; Mulder, Chris J.; Jansen, Peter L. M.; Stoker, Jaap

    2011-01-01

    The purpose of this study was to assess, with histopathologic control, the use of open-system 1-T (1)H MR spectroscopy for the evaluation of hepatic steatosis in morbidly obese patients undergoing gastric bypass surgery. Patients underwent (1)H MR spectroscopy (MRS) for the assessment of steatosis

  4. Digital Receiver Design for Transmitted Reference Ultra-Wideband Systems

    Directory of Open Access Journals (Sweden)

    Wang Yiyin

    2009-01-01

    Full Text Available Abstract A complete detection, channel estimation, synchronization, and equalization scheme for a transmitted reference (TR ultra-wideband (UWB system is proposed in this paper. The scheme is based on a data model which admits a moderate data rate and takes both the interframe interference (IFI and the intersymbol interference (ISI into consideration. Moreover, the bias caused by the interpulse interference (IPI in one frame is also taken into account. Based on the analysis of the stochastic properties of the received signals, several detectors are studied and evaluated. Furthermore, a data-aided two-stage synchronization strategy is proposed, which obtains sample-level timing in the range of one symbol at the first stage and then pursues symbol-level synchronization by looking for the header at the second stage. Three channel estimators are derived to achieve joint channel and timing estimates for the first stage, namely, the linear minimum mean square error (LMMSE estimator, the least squares (LS estimator, and the matched filter (MF. We check the performance of different combinations of channel estimation and equalization schemes and try to find the best combination, that is, the one providing a good tradeoff between complexity and performance.

  5. Digital Receiver Design for Transmitted Reference Ultra-Wideband Systems

    Directory of Open Access Journals (Sweden)

    Yiyin Wang

    2009-01-01

    Full Text Available A complete detection, channel estimation, synchronization, and equalization scheme for a transmitted reference (TR ultra-wideband (UWB system is proposed in this paper. The scheme is based on a data model which admits a moderate data rate and takes both the interframe interference (IFI and the intersymbol interference (ISI into consideration. Moreover, the bias caused by the interpulse interference (IPI in one frame is also taken into account. Based on the analysis of the stochastic properties of the received signals, several detectors are studied and evaluated. Furthermore, a data-aided two-stage synchronization strategy is proposed, which obtains sample-level timing in the range of one symbol at the first stage and then pursues symbol-level synchronization by looking for the header at the second stage. Three channel estimators are derived to achieve joint channel and timing estimates for the first stage, namely, the linear minimum mean square error (LMMSE estimator, the least squares (LS estimator, and the matched filter (MF. We check the performance of different combinations of channel estimation and equalization schemes and try to find the best combination, that is, the one providing a good tradeoff between complexity and performance.

  6. Reference pricing system and competition: case study from Portugal.

    Science.gov (United States)

    Portela, Conceiçăo

    2009-10-01

    To characterize the patterns of competition for a sample of drugs in the Portuguese pharmaceutical market before (January 2002-March 2003) and after (April 2003-June 2003) the introduction of the reference pricing system (RPS). We performed a descriptive, retrospective, longitudinal analysis, with monthly observations from January 2002 until June 2003 of 15 homogeneous groups. The groups represented the upper limit of public pharmaceutical expenditure in the RPS segment in 2003 (n=270). Measures of competition were: 1) number of presentations; 2) prescriptions' concentration in the generic and originator (brand) segments, using Herfindahl-Hirschman Index (HHI); and 3) dominant positions of market leader in the homogeneous group. A correlation analysis between the number of presentations, the HHI, and the dominant position of the market leader was performed using Pearson coefficient of correlation. The structure of the market changed with the introduction of RPS. We found an increasing number of generic presentations (from 4+/-3 to 7+/-4; mean+/-standard deviation) and a decrease in the HHI for the generics market segment (from 0.7+/-0.2 to 0.6+/-0.3). There was a negative correlation between those variables that increased after the introduction of RPS (from -0.6 to -0.8). The HHI for brands and the dominant positions remained unchanged. After the implementation of RPS, the increased competition was mainly driven by economic and social agents in the generics market segment but not in the brands market segment.

  7. Computation and brain processes, with special reference to neuroendocrine systems.

    Science.gov (United States)

    Toni, Roberto; Spaletta, Giulia; Casa, Claudia Della; Ravera, Simone; Sandri, Giorgio

    2007-01-01

    The development of neural networks and brain automata has made neuroscientists aware that the performance limits of these brain-like devices lies, at least in part, in their computational power. The computational basis of a. standard cybernetic design, in fact, refers to that of a discrete and finite state machine or Turing Machine (TM). In contrast, it has been suggested that a number of human cerebral activites, from feedback controls up to mental processes, rely on a mixing of both finitary, digital-like and infinitary, continuous-like procedures. Therefore, the central nervous system (CNS) of man would exploit a form of computation going beyond that of a TM. This "non conventional" computation has been called hybrid computation. Some basic structures for hybrid brain computation are believed to be the brain computational maps, in which both Turing-like (digital) computation and continuous (analog) forms of calculus might occur. The cerebral cortex and brain stem appears primary candidate for this processing. However, also neuroendocrine structures like the hypothalamus are believed to exhibit hybrid computional processes, and might give rise to computational maps. Current theories on neural activity, including wiring and volume transmission, neuronal group selection and dynamic evolving models of brain automata, bring fuel to the existence of natural hybrid computation, stressing a cooperation between discrete and continuous forms of communication in the CNS. In addition, the recent advent of neuromorphic chips, like those to restore activity in damaged retina and visual cortex, suggests that assumption of a discrete-continuum polarity in designing biocompatible neural circuitries is crucial for their ensuing performance. In these bionic structures, in fact, a correspondence exists between the original anatomical architecture and synthetic wiring of the chip, resulting in a correspondence between natural and cybernetic neural activity. Thus, chip "form

  8. Light-water reactors reference system classification for the European reliability data system (ERDS)

    International Nuclear Information System (INIS)

    Melis, M.; Mancini, G.

    1982-01-01

    The reference system classification represents a basic stage in the organization of the European reliability data system (ERDS) for light-water reactors, a project actually in development at the Joint Research Centre, Ispra. This project is concerned with operational reliability data collection from the various ''national'' data banks, and centralization in a European reliability data system, so improving the significance of the resulting reliability evaluations. In the framework of the ERDS project, the reference system classification provides a LWR functional break-down and represents a plant-unique identification in the process of homogenization of event-data coming from the various ''national'' organizations. The report, after a brief description of the main objectives of the ERDS project, reviews the criteria followed in the elaboration of the reference system classification; then the detailed classification is presented. The nuclear power station is subdivided in about 180 systems. To each system a sheet is associated, containing: a comprehensive description of system-functions and boundaries; a descritpion of the plant operating mode, linked to the various system functions; a list of the main interface system; and finally, a list of the main components, including type and safety classification

  9. Semen analysis in fertile patients undergoing vasectomy: reference values and variations according to age, length of sexual abstinence, seasonality, smoking habits and caffeine intake

    OpenAIRE

    Sobreiro,Bernardo Passos; Lucon,Antonio Marmo; Pasqualotto,Fábio Firmbach; Hallak,Jorge; Athayde,Kelly Silveira; Arap,Sami

    2005-01-01

    CONTEXT AND OBJECTIVE: Recent studies have shown regional and population differences in semen characteristics. The objective was to establish reference values for semen analysis and to verify the effect that age, length of sexual abstinence, seasonality, smoking habits and coffee consumption have on fertile individuals’ semen characteristics. DESIGN AND SETTING: Prospective study in the Urology Division, Hospital das Clínicas, Universidade de São Paulo. METHODS: Between September 1999 and Aug...

  10. Comparison of pain scores between patients undergoing panretinal photocoagulation using navigated or pattern scan laser systems

    Directory of Open Access Journals (Sweden)

    Umit Ubeyt Inan

    2016-02-01

    Full Text Available ABSTRACT Purpose: To compare the pain responses of patients with proliferative diabetic retinopathy (PDR undergoing panretinal photocoagulation (PRP using either pattern scan laser (PASCAL or navigated laser photocoagulation (NAVILAS. Methods: Patients diagnosed with PDR were randomly assigned to undergo either PASCAL or NAVILAS photocoagulation treatment. PRP was performed using the multi-shot mode with a spot size of 200-400 µm and a pulse duration of 30 ms to obtain a white-grayish spot on the retina. Parameters were identical in both procedures. After 30 min of PRP application, patients were asked to verbally describe their pain perception as either "none," "mild," "moderate," "severe," or "very severe" using a verbal rating scale (VRS and visual analog scale (VAS by indicating a score from "0" to "10," representing the severity of pain from "no pain" to "severe pain." Results: A total of 60 eyes of 60 patients (20 females and 40 males diagnosed with PDR were treated. The mean age of patients was 62.22 ± 9.19 years, and the mean diabetes duration was 195.47 ± 94.54 months. The mean number of laser spots delivered during PRP was 389.47 ± 71.52 in the NAVILAS group and 392.70 ± 54.33 in the PASCAL group (p=0.57. The difference in pain responses between patients in the NAVILAS and PASCAL groups was significant with regard to the mean VRS (1.10 ± 0.67 and 1.47 ± 0.69, respectively; p=0.042 and mean VAS (2.13 ± 1.17 and 2.97 ± 1.35, respectively; p=0.034 scores. Conclusions: Pain responses in patients undergoing PRP with a 30-ms pulse duration were significantly milder in the NAVILAS group than in the PASCAL group.

  11. Radon-daughter chamber instrumentation system reference manual

    International Nuclear Information System (INIS)

    Showalter, R.; Johnson, L.

    1985-01-01

    The radon-daughter chamber instrumentation system collects environmental data from the radon-daughter chamber. These data are then recorded on a Tandberg system tape cartridge and transmitted to the HP-1000 computer for processing. Generators which inject radon and condensation nuclei into the chamber are also included with the instrumentation system

  12. Psychological evaluation of patients undergoing MR imaging: analysis, proposals for improvement and place of open magnet systems

    International Nuclear Information System (INIS)

    Tillier, Ph.; Leclet, H.; Laplanche, T.; Madoux, M.; Picoult, C.; Delvalle, A.; Delforge, P.M.; Malgouyres, A.

    1997-01-01

    Many patients report anxiety during MR imaging. Anxiety is due to immobility, coil noise, high temperature, duration of the examination and shape of the system. On basis of a prospective series of 250 patients undergoing MR studies, we have analysed mechanisms and reasons of anxiety. Psychological strategies are useful to reduce anxiety and improve patients' cooperation and relaxation. The easiest and most effective way is to inform the distressed patient. Information about the MRI examination must be clear and simple. Open field magnets improve comfort and global conditions of the examination realisation. Psychological consequences are less important. Open field MR systems reduce claustrophobia induced by MR imaging. (author)

  13. The Nuclear Science References (NSR) database and Web Retrieval System

    International Nuclear Information System (INIS)

    Pritychenko, B.; Betak, E.; Kellett, M.A.; Singh, B.; Totans, J.

    2011-01-01

    The Nuclear Science References (NSR) database together with its associated Web interface is the world's only comprehensive source of easily accessible low- and intermediate-energy nuclear physics bibliographic information for more than 200,000 articles since the beginning of nuclear science. The weekly updated NSR database provides essential support for nuclear data evaluation, compilation and research activities. The principles of the database and Web application development and maintenance are described. Examples of nuclear structure, reaction and decay applications are specifically included. The complete NSR database is freely available at the websites of the National Nuclear Data Center (http://www.nndc.bnl.gov/nsr) and the International Atomic Energy Agency (http://www-nds.iaea.org/nsr).

  14. Semen analysis in fertile patients undergoing vasectomy: reference values and variations according to age, length of sexual abstinence, seasonality, smoking habits and caffeine intake

    Directory of Open Access Journals (Sweden)

    Bernardo Passos Sobreiro

    Full Text Available CONTEXT AND OBJECTIVE: Recent studies have shown regional and population differences in semen characteristics. The objective was to establish reference values for semen analysis and to verify the effect that age, length of sexual abstinence, seasonality, smoking habits and coffee consumption have on fertile individuals’ semen characteristics. DESIGN AND SETTING: Prospective study in the Urology Division, Hospital das Clínicas, Universidade de São Paulo. METHODS: Between September 1999 and August 2002, 500 fertile men requesting a vasectomy for sterilization purposes were asked to provide a semen sample before the vasectomy. We evaluated the effects of age, sexual abstinence, seasonality, smoking and coffee consumption on semen characteristics. RESULTS: Compared with World Health Organization values, 87.2% of the patients presented sperm morphology below the normal level. A significant decline in semen volume, sperm motility and sperm morphology in patients over 45 years of age was observed. In patients with 5 days or more of abstinence, there was reduced sperm motility. The lowest values for sperm concentration, motility and morphology were observed in summer and the highest in winter. No differences in semen parameters relating to smoking were detected. Patients who drank six or more cups of coffee per day presented higher sperm motility. CONCLUSIONS: Our sample had a very low percentage of normal sperm morphology. Only sperm morphology showed a high abnormality rate. Differences in semen parameters with regard to age, length of sexual abstinence, seasonality and coffee consumption were identified. No differences relating to smoking were detected.

  15. Semen analysis in fertile patients undergoing vasectomy: reference values and variations according to age, length of sexual abstinence, seasonality, smoking habits and caffeine intake.

    Science.gov (United States)

    Sobreiro, Bernardo Passos; Lucon, Antonio Marmo; Pasqualotto, Fábio Firmbach; Hallak, Jorge; Athayde, Kelly Silveira; Arap, Sami

    2005-07-07

    Recent studies have shown regional and population differences in semen characteristics. The objective was to establish reference values for semen analysis and to verify the effect that age, length of sexual abstinence, seasonality, smoking habits and coffee consumption have on fertile individuals' semen characteristics. Prospective study in the Urology Division, Hospital das Clínicas, Universidade de São Paulo. Between September 1999 and August 2002, 500 fertile men requesting a vasectomy for sterilization purposes were asked to provide a semen sample before the vasectomy. We evaluated the effects of age, sexual abstinence, seasonality, smoking and coffee consumption on semen characteristics. Compared with World Health Organization values, 87.2% of the patients presented sperm morphology below the normal level. A significant decline in semen volume, sperm motility and sperm morphology in patients over 45 years of age was observed. In patients with 5 days or more of abstinence, there was reduced sperm motility. The lowest values for sperm concentration, motility and morphology were observed in summer and the highest in winter. No differences in semen parameters relating to smoking were detected. Patients who drank six or more cups of coffee per day presented higher sperm motility. Our sample had a very low percentage of normal sperm morphology. Only sperm morphology showed a high abnormality rate. Differences in semen parameters with regard to age, length of sexual abstinence, seasonality and coffee consumption were identified. No differences relating to smoking were detected.

  16. A Methodology For Developing an Agent Systems Reference Architecture

    Science.gov (United States)

    2010-05-01

    agent framworks , we create an abstraction noting similarities and differences. The differences are documented as points of variation. The result...situated in the physical en- vironment. Addressing how conceptual components of an agent system is beneficial to agent system architects, developers, and

  17. Advances in Geologic Disposal System Modeling and Shale Reference Cases

    Energy Technology Data Exchange (ETDEWEB)

    Mariner, Paul E. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Stein, Emily R. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Frederick, Jennifer M. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Sevougian, S. David [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Hammond, Glenn Edward [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2017-09-22

    The Spent Fuel and Waste Science and Technology (SFWST) Campaign of the U.S. Department of Energy (DOE) Office of Nuclear Energy (NE), Office of Fuel Cycle Technology (OFCT) is conducting research and development (R&D) on geologic disposal of spent nuclear fuel (SNF) and high level nuclear waste (HLW). Two high priorities for SFWST disposal R&D are design concept development and disposal system modeling (DOE 2011, Table 6). These priorities are directly addressed in the SFWST Generic Disposal Systems Analysis (GDSA) work package, which is charged with developing a disposal system modeling and analysis capability for evaluating disposal system performance for nuclear waste in geologic media (e.g., salt, granite, shale, and deep borehole disposal).

  18. A Reference Model for Software and System Inspections. White Paper

    Science.gov (United States)

    He, Lulu; Shull, Forrest

    2009-01-01

    Software Quality Assurance (SQA) is an important component of the software development process. SQA processes provide assurance that the software products and processes in the project life cycle conform to their specified requirements by planning, enacting, and performing a set of activities to provide adequate confidence that quality is being built into the software. Typical techniques include: (1) Testing (2) Simulation (3) Model checking (4) Symbolic execution (5) Management reviews (6) Technical reviews (7) Inspections (8) Walk-throughs (9) Audits (10) Analysis (complexity analysis, control flow analysis, algorithmic analysis) (11) Formal method Our work over the last few years has resulted in substantial knowledge about SQA techniques, especially the areas of technical reviews and inspections. But can we apply the same QA techniques to the system development process? If yes, what kind of tailoring do we need before applying them in the system engineering context? If not, what types of QA techniques are actually used at system level? And, is there any room for improvement.) After a brief examination of the system engineering literature (especially focused on NASA and DoD guidance) we found that: (1) System and software development process interact with each other at different phases through development life cycle (2) Reviews are emphasized in both system and software development. (Figl.3). For some reviews (e.g. SRR, PDR, CDR), there are both system versions and software versions. (3) Analysis techniques are emphasized (e.g. Fault Tree Analysis, Preliminary Hazard Analysis) and some details are given about how to apply them. (4) Reviews are expected to use the outputs of the analysis techniques. In other words, these particular analyses are usually conducted in preparation for (before) reviews. The goal of our work is to explore the interaction between the Quality Assurance (QA) techniques at the system level and the software level.

  19. Nuclear emergency response exercises and decision support systems - integrating domestic experience with international reference systems

    International Nuclear Information System (INIS)

    Slavnicu, D.S.; Vamanu, D.V.; Gheorghiu, D.; Acasandrei, V.T.; Slavnicu, E.

    2010-01-01

    The paper glosses on the experience of a research-oriented team routinely involved in emergency preparedness and response management activities, with the assimilation, implementation, and application of decision support systems (DSS) of continental reference in Europe, and the development of supportive, domestic radiological assessment tools. Two exemplary nuclear alert exercises are discussed, along with solutions that emerged during drill planning and execution, to make decision support tools of various origins and strength to work synergistically and complement each other. (authors)

  20. Solid municipal waste management: Systems and reference technologies

    International Nuclear Information System (INIS)

    Ciancio, G.; Mura, A.

    1993-03-01

    The management of solid municipal wastes comprises simple methods such as dumping into suitably controlled waste disposal sites, and more complex solutions, which can include waste segregation, some form of materials and/or energy recovery, and the use of combined cycle combustion systems. All these methods, however, require environmental protection systems with custom designed techniques, equipment and safeguards. This paper reviews the technical-economic aspects of different pollution control options currently available to meet the specific requirements of various waste management alternatives

  1. A global reference model of the domain name system

    NARCIS (Netherlands)

    Koc, Y.; Jamakovic, A.; Gijsen, B.M.M.

    2012-01-01

    The domain name system (DNS) is a crucial component of the Internet. At this time, the DNS is facing major changes such as the introduction of DNSSEC and Internationalized Domain Name extensions (IDNs), the adoption of IPv6 and the upcoming extension of new generic top-level domains. These changes

  2. Phase modulated high density collinear holographic data storage system with phase-retrieval reference beam locking and orthogonal reference encoding.

    Science.gov (United States)

    Liu, Jinpeng; Horimai, Hideyoshi; Lin, Xiao; Huang, Yong; Tan, Xiaodi

    2018-02-19

    A novel phase modulation method for holographic data storage with phase-retrieval reference beam locking is proposed and incorporated into an amplitude-encoding collinear holographic storage system. Unlike the conventional phase retrieval method, the proposed method locks the data page and the corresponding phase-retrieval interference beam together at the same location with a sequential recording process, which eliminates piezoelectric elements, phase shift arrays and extra interference beams, making the system more compact and phase retrieval easier. To evaluate our proposed phase modulation method, we recorded and then recovered data pages with multilevel phase modulation using two spatial light modulators experimentally. For 4-level, 8-level, and 16-level phase modulation, we achieved the bit error rate (BER) of 0.3%, 1.5% and 6.6% respectively. To further improve data storage density, an orthogonal reference encoding multiplexing method at the same position of medium is also proposed and validated experimentally. We increased the code rate of pure 3/16 amplitude encoding method from 0.5 up to 1.0 and 1.5 using 4-level and 8-level phase modulation respectively.

  3. 49 CFR 614.101 - Cross-reference to management systems.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 7 2010-10-01 2010-10-01 false Cross-reference to management systems. 614.101... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION TRANSPORTATION INFRASTRUCTURE MANAGEMENT § 614.101 Cross-reference to management systems. The regulations in 23 CFR Part 500, subparts A and B shall be followed in...

  4. Physical habitat simulation system reference manual: version II

    Science.gov (United States)

    Milhous, Robert T.; Updike, Marlys A.; Schneider, Diane M.

    1989-01-01

    There are four major components of a stream system that determine the productivity of the fishery (Karr and Dudley 1978). These are: (1) flow regime, (2) physical habitat structure (channel form, substrate distribution, and riparian vegetation), (3) water quality (including temperature), and (4) energy inputs from the watershed (sediments, nutrients, and organic matter). The complex interaction of these components determines the primary production, secondary production, and fish population of the stream reach. The basic components and interactions needed to simulate fish populations as a function of management alternatives are illustrated in Figure I.1. The assessment process utilizes a hierarchical and modular approach combined with computer simulation techniques. The modular components represent the "building blocks" for the simulation. The quality of the physical habitat is a function of flow and, therefore, varies in quality and quantity over the range of the flow regime. The conceptual framework of the Incremental Methodology and guidelines for its application are described in "A Guide to Stream Habitat Analysis Using the Instream Flow Incremental Methodology" (Bovee 1982). Simulation of physical habitat is accomplished using the physical structure of the stream and streamflow. The modification of physical habitat by temperature and water quality is analyzed separately from physical habitat simulation. Temperature in a stream varies with the seasons, local meteorological conditions, stream network configuration, and the flow regime; thus, the temperature influences on habitat must be analysed on a stream system basis. Water quality under natural conditions is strongly influenced by climate and the geological materials, with the result that there is considerable natural variation in water quality. When we add the activities of man, the possible range of water quality possibilities becomes rather large. Consequently, water quality must also be analysed on a

  5. Data quality system using reference dictionaries and edit distance algorithms

    Science.gov (United States)

    Karbarz, Radosław; Mulawka, Jan

    2015-09-01

    The real art of management it is important to make smart decisions, what in most of the cases is not a trivial task. Those decisions may lead to determination of production level, funds allocation for investments etc. Most of the parameters in decision-making process such as: interest rate, goods value or exchange rate may change. It is well know that these parameters in the decision-making are based on the data contained in datamarts or data warehouse. However, if the information derived from the processed data sets is the basis for the most important management decisions, it is required that the data is accurate, complete and current. In order to achieve high quality data and to gain from them measurable business benefits, data quality system should be used. The article describes the approach to the problem, shows the algorithms in details and their usage. Finally the test results are provide. Test results show the best algorithms (in terms of quality and quantity) for different parameters and data distribution.

  6. Inaccuracies when mixing coordinate reference frameworks in a system of systems simulation

    CSIR Research Space (South Africa)

    Duvenhage, B

    2007-09-01

    Full Text Available commonly used are flat and spherical earth. Another well known ERM is the World Geodetic System from 1984 (WGS 84). For the purposes of this paper the authors however focus on the simpler flat and spherical earth models with example coordinate... words, the equatorial and pole to pole diameters of the earth, as modelled in this ERM, are equal. This paper will use the term ‘real world’ ERMs to refer to spherical, WGS 84 and better ERM approximations. A. The Earth-Centred, Earth...

  7. Speed Sensorless Control of PMSM using Model Reference Adaptive System and RBFN

    OpenAIRE

    Wei Gao; Zhirong Guo

    2013-01-01

    In the speed sensorless vector control system, the amended method of estimating the rotor speed about model reference adaptive system (MRAS) based on radial basis function neural network (RBFN) for PMSM sensorless vector control system was presented. Based on the PI regulator, the radial basis function neural network which is more prominent learning efficiency and performance is combined with MRAS. The reference model and the adjust model are the PMSM itself and the PMSM current, respectively...

  8. On the theory of transformations of coordinates for massive systems of reference

    International Nuclear Information System (INIS)

    Sadykov, B.S.

    1978-01-01

    Suggested is a new local group of coordinate transformations of reference systems connected with massive bodies, such as the Earth, the Sun and so on, which are rather inertial in the kinematic relation, but possess different gravitational fields. The effect of the gravitational field of the reference body upon the metric of the system is taken into account. For identical systems the new group transfers into the Lorentz group

  9. An implicit adaptation algorithm for a linear model reference control system

    Science.gov (United States)

    Mabius, L.; Kaufman, H.

    1975-01-01

    This paper presents a stable implicit adaptation algorithm for model reference control. The constraints for stability are found using Lyapunov's second method and do not depend on perfect model following between the system and the reference model. Methods are proposed for satisfying these constraints without estimating the parameters on which the constraints depend.

  10. The Necessity of Real-Time: Fact and Fiction in Digital Reference Systems.

    Science.gov (United States)

    Lankes, R. David; Shostack, Pauline

    2002-01-01

    Discussion of digital reference services and the use of real-time versus asynchronous services such as email focuses on data from the AskERIC digital reference service to demonstrate that asynchronous services are not only useful but may have greater utility than real-time systems. (Author/LRW)

  11. Flow confirmation study for central venous port in oncologic outpatient undergoing chemotherapy: Evaluation of suspected system-related mechanical complications

    International Nuclear Information System (INIS)

    Sofue, Keitaro; Arai, Yasuaki; Takeuchi, Yoshito; Sugimura, Kazuro

    2013-01-01

    Purpose: To evaluate the efficacy and outcome of a flow confirmation study (FCS) in oncologic outpatients undergoing chemotherapy suspected of a central venous port (CVP) system-related mechanical complication. Materials and methods: A total of 66 patients (27 men, 39 women; mean age, 60 years) received FCS for the following reasons: prolonged infusion time during chemotherapy (n = 32), inability to inject saline fluid (n = 15), lateral neck and/or back pain (n = 6), subcutaneous extravasation of anticancer drug (n = 5), arm swelling (n = 4), and inability to puncture the port (n = 4). FCS consisted of examining the position of CVP, potential secondary shifts or fractures, and integrity of the system using contrast material through the port. Results: Of the 66 patients, 43 had an abnormal finding uncovered by FCS. The most frequent abnormal findings was catheter kinking (n = 22). Explantation and reimplantation of the CVP system was required in 21 of the 66 patients. Remaining 45 patients were able continue using the CVP system after the FCS without any system malfunction. Conclusion: FCS was effective for evaluating CVP system-related mechanical complications and was useful for deciding whether CVP system explantation and reimplantation was required

  12. Flow confirmation study for central venous port in oncologic outpatient undergoing chemotherapy: Evaluation of suspected system-related mechanical complications

    Energy Technology Data Exchange (ETDEWEB)

    Sofue, Keitaro, E-mail: ksofue@ncc.go.jp [Divisions of Diagnostic Radiology, National Cancer Center Hospital (Japan); Department of Radiology, Kobe University, Graduate School of Medicine (Japan); Arai, Yasuaki; Takeuchi, Yoshito [Divisions of Diagnostic Radiology, National Cancer Center Hospital (Japan); Sugimura, Kazuro [Department of Radiology, Kobe University, Graduate School of Medicine (Japan)

    2013-11-01

    Purpose: To evaluate the efficacy and outcome of a flow confirmation study (FCS) in oncologic outpatients undergoing chemotherapy suspected of a central venous port (CVP) system-related mechanical complication. Materials and methods: A total of 66 patients (27 men, 39 women; mean age, 60 years) received FCS for the following reasons: prolonged infusion time during chemotherapy (n = 32), inability to inject saline fluid (n = 15), lateral neck and/or back pain (n = 6), subcutaneous extravasation of anticancer drug (n = 5), arm swelling (n = 4), and inability to puncture the port (n = 4). FCS consisted of examining the position of CVP, potential secondary shifts or fractures, and integrity of the system using contrast material through the port. Results: Of the 66 patients, 43 had an abnormal finding uncovered by FCS. The most frequent abnormal findings was catheter kinking (n = 22). Explantation and reimplantation of the CVP system was required in 21 of the 66 patients. Remaining 45 patients were able continue using the CVP system after the FCS without any system malfunction. Conclusion: FCS was effective for evaluating CVP system-related mechanical complications and was useful for deciding whether CVP system explantation and reimplantation was required.

  13. Reference Concepts for a Space-Based Hydrogen-Oxygen Combustion, Turboalternator, Burst Power System

    National Research Council Canada - National Science Library

    Edenburn, Michael

    1990-01-01

    This report describes reference concepts for a hydrogen-oxygen combustion, turboalternator power system that supplies power during battle engagement to a space-based, ballistic missile defense platform...

  14. Initial Stage Reference Search : Driver Simulators to Test Shared Controls, Limited Autonomy Vehicle Systems

    Science.gov (United States)

    2015-09-01

    This literature review and reference scanning focuses on the use of driver simulators for semiautonomous (or shared control) vehicle systems (2012present), including related research from other modes of transportation (e.g., rail or aviation). Foc...

  15. A reference system for animal biometrics: application to the northern leopard frog

    Science.gov (United States)

    Petrovska-Delacretaz, D.; Edwards, A.; Chiasson, J.; Chollet, G.; Pilliod, D.S.

    2014-01-01

    Reference systems and public databases are available for human biometrics, but to our knowledge nothing is available for animal biometrics. This is surprising because animals are not required to give their agreement to be in a database. This paper proposes a reference system and database for the northern leopard frog (Lithobates pipiens). Both are available for reproducible experiments. Results of both open set and closed set experiments are given.

  16. Sourcebook for energy assessment. [Reference Energy Systems for 1972-2020

    Energy Technology Data Exchange (ETDEWEB)

    Beller, M. (ed.)

    1975-12-01

    An analytical approach is presented that is broadly applicable to the assessment of energy technologies and policies. Using the Reference Energy System approach, it permits the examination of the economic, environmental, and resource implications resulting from the substitution of one fuel or technology for another. Included as tools for such analyses are the necessary data and methodology, as well as a set of Reference Energy Systems covering the 1972-2020 period to serve as baselines for the perturbation analyses of interest. 46 tables, 25 figures, 71 references.

  17. Analyzing Risks and Vulnerabilities of Various Computer Systems and Undergoing Exploitation using Embedded Devices

    Science.gov (United States)

    Branch, Drew Alexander

    2014-01-01

    Security is one of the most if not the most important areas today. After the several attacks on the United States, security everywhere has heightened from airports to communication among the military branches legionnaires. With advanced persistent threats (APTs) on the rise following Stuxnet, government branches and agencies are required, more than ever, to follow several standards, policies and procedures to reduce the likelihood of a breach. Attack vectors today are very advanced and are going to continue to get more and more advanced as security controls advance. This creates a need for networks and systems to be in an updated, patched and secured state in a launch control system environment. Attacks on critical systems are becoming more and more relevant and frequent. Nation states are hacking into critical networks that might control electrical power grids or water dams as well as carrying out advanced persistent threat (APTs) attacks on government entities. NASA, as an organization, must protect its self from attacks from all different types of attackers with different motives. Although the International Space Station was created, there is still competition between the different space programs. With that in mind, NASA might get attacked and breached for various reasons such as espionage or sabotage. My project will provide a way for NASA to complete an in house penetration test which includes: asset discovery, vulnerability scans, exploit vulnerabilities and also provide forensic information to harden systems. Completing penetration testing is a part of the compliance requirements of the Federal Information Security Act (FISMA) and NASA NPR 2810.1 and related NASA Handbooks. This project is to demonstrate how in house penetration testing can be conducted that will satisfy all of the compliance requirements of the National Institute of Standards and Technology (NIST), as outlined in FISMA. By the end of this project, I hope to have carried out the tasks stated

  18. Systemic assessment of patients undergoing dental implant surgeries: A trans- and post-operative analysis

    OpenAIRE

    Sanjay Byakodi; Sachin Kumar; Rajesh Kumar Reddy; Vipin Kumar; Shipra Sepolia; Shivangi Gupta; Harkanwal Preet Singh

    2017-01-01

    Background: Procedure-related and patient-related factors influence the prognosis of dental implants to a major extent. Hence, we aimed to evaluate and analyze various systemic factors in patients receiving dental implants. Materials and Methods: Fifty-one patients were included in the study, in which a total of 110 dental implants were placed. Complete examination of the subjects was done before and after placement of dental implants. Implant surgery was planned, and osseointegrated dental i...

  19. Synchronous behaviour of two interacting oscillatory systems undergoing quasiperiodic route to chaos.

    Science.gov (United States)

    Mondal, S; Pawar, S A; Sujith, R I

    2017-10-01

    Thermoacoustic instability, caused by a positive feedback between the unsteady heat release and the acoustic field in a combustor, is a major challenge faced in most practical combustors such as those used in rockets and gas turbines. We employ the synchronization theory for understanding the coupling between the unsteady heat release and the acoustic field of a thermoacoustic system. Interactions between coupled subsystems exhibiting different collective dynamics such as periodic, quasiperiodic, and chaotic oscillations are addressed. Even though synchronization studies have focused on different dynamical states separately, synchronous behaviour of two coupled systems exhibiting a quasiperiodic route to chaos has not been studied. In this study, we report the first experimental observation of different synchronous behaviours between two subsystems of a thermoacoustic system exhibiting such a transition as reported in Kabiraj et al. [Chaos 22, 023129 (2012)]. A rich variety of synchronous behaviours such as phase locking, intermittent phase locking, and phase drifting are observed as the dynamics of such subsystem change. The observed synchronization behaviour is further characterized using phase locking value, correlation coefficient, and relative mean frequency. These measures clearly reveal the boundaries between different states of synchronization.

  20. Scoring system predictive of survival for patients undergoing stereotactic body radiation therapy for liver tumors

    Directory of Open Access Journals (Sweden)

    Kress Marie-Adele S

    2012-09-01

    Full Text Available Abstract Background Stereotactic body radiation therapy (SBRT is an emerging treatment option for liver tumors. This study evaluated outcomes after SBRT to identify prognostic variables and to develop a novel scoring system predictive of survival. Methods The medical records of 52 patients with a total of 85 liver lesions treated with SBRT from 2003 to 2010 were retrospectively reviewed. Twenty-four patients had 1 lesion; 27 had 2 or more. Thirteen lesions were primary tumors; 72 were metastases. Fiducials were placed in all patients prior to SBRT. The median prescribed dose was 30 Gy (range, 16 – 50 Gy in a median of 3 fractions (range, 1–5. Results With median follow-up of 11.3 months, median overall survival (OS was 12.5 months, and 1 year OS was 50.8%. In 42 patients with radiographic follow up, 1 year local control was 74.8%. On univariate analysis, number of lesions (p = 0.0243 and active extralesional disease (p  Conclusions SBRT offers a safe and feasible treatment option for liver tumors. A prognostic scoring system based on the number of liver lesions, activity of extralesional disease, and KPS predicts survival following SBRT and can be used as a guide for prospective validation and ultimately for treatment decision-making.

  1. Carbon dynamics in a Late Quaternary-age coastal limestone aquifer system undergoing saltwater intrusion.

    Science.gov (United States)

    Bryan, Eliza; Meredith, Karina T; Baker, Andy; Andersen, Martin S; Post, Vincent E A

    2017-12-31

    This study investigates the inorganic and organic aspects of the carbon cycle in groundwaters throughout the freshwater lens and transition zone of a carbonate island aquifer and identifies the transformation of carbon throughout the system. We determined 14 C and 13 C carbon isotope values for both DIC and DOC in groundwaters, and investigated the composition of DOC throughout the aquifer. In combination with hydrochemical and 3 H measurements, the chemical evolution of groundwaters was then traced from the unsaturated zone to the deeper saline zone. The data revealed three distinct water types: Fresh (F), Transition zone 1 (T1) and Transition zone 2 (T2) groundwaters. The 3 H values in F and T1 samples indicate that these groundwaters are mostly modern. 14 C DOC values are higher than 14 C DIC values and are well correlated with 3 H values. F and T1 groundwater geochemistry is dominated by carbonate mineral recrystallisation reactions that add dead carbon to the groundwater. T2 groundwaters are deeper, saline and characterised by an absence of 3 H, lower 14 C DOC values and a different DOC composition, namely a higher proportion of Humic Substances relative to total DOC. The T2 groundwaters are suggested to result from either the slow circulation of water within the seawater wedge, or from old remnant seawater caused by past sea level highstands. While further investigations are required to identify the origin of the T2 groundwaters, this study has identified their occurrence and shown that they did not evolve along the same pathway as fresh groundwaters. This study has also shown that a combined approach using 14 C and 13 C carbon isotope values for both DIC and DOC and the composition of DOC, as well as hydrochemical and 3 H measurements, can provide invaluable information regarding the transformation of carbon in a groundwater system and the evolution of fresh groundwater recharge. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Characterisation of pristine Polish river systems and their use as reference conditions for Dutch river systems

    NARCIS (Netherlands)

    Nijboer, R.C.; Verdonschot, P.F.M.; Piechocki, A.; Tonczyk, G.; Klukowska, M.

    2006-01-01

    A central feature of the European Water Framework Directive are the reference conditions. The ecological quality status is determined by calculating the distance between the present situation and the reference conditions. To describe reference conditions the natural variation of biota in pristine

  3. The development of an MRI lesion quantifying system for multiple sclerosis patients undergoing treatment

    Science.gov (United States)

    Moin, Paymann; Ma, Kevin; Amezcua, Lilyana; Gertych, Arkadiusz; Liu, Brent

    2009-02-01

    Multiple sclerosis (MS) is a demyelinating disease of the central nervous system that affects approximately 2.5 million people worldwide. Magnetic resonance imaging (MRI) is an established tool for the assessment of disease activity, progression and response to treatment. The progression of the disease is variable and requires routine follow-up imaging studies. Currently, MRI quantification of multiple sclerosis requires a manual approach to lesion measurement and yields an estimate of lesion volume and interval change. In the setting of several prior studies and a long treatment history, trends related to treatment change quickly become difficult to extrapolate. Our efforts seek to develop an imaging informatics based MS lesion computer aided detection (CAD) package to quantify and track MS lesions including lesion load, volume, and location. Together, with select clinical parameters, this data will be incorporated into an MS specific e- Folder to provide decision support to evaluate and assess treatment options for MS in a manner tailored specifically to an individual based on trends in MS presentation and progression.

  4. Systemic Assessment of Patients Undergoing Dental Implant Surgeries: A Trans- and Post-operative Analysis.

    Science.gov (United States)

    Byakodi, Sanjay; Kumar, Sachin; Reddy, Rajesh Kumar; Kumar, Vipin; Sepolia, Shipra; Gupta, Shivangi; Singh, Harkanwal Preet

    2017-01-01

    Procedure-related and patient-related factors influence the prognosis of dental implants to a major extent. Hence, we aimed to evaluate and analyze various systemic factors in patients receiving dental implants. Fifty-one patients were included in the study, in which a total of 110 dental implants were placed. Complete examination of the subjects was done before and after placement of dental implants. Implant surgery was planned, and osseointegrated dental implants were placed in the subjects. Postoperative evaluation of the dental implant patients was done after 3 weeks. Anxiety levels were determined using State-Trait Anxiety Inventory (STAI) questionnaire on the surgery day and after 1 week of surgery. The participant describes how they feel at the moment by responding to twenty items as follows: (1) absolutely not, (2) slightly, (3) somewhat, or (4) very much. All the results were recorded and statistical analyzed by SPSS software. Out of 51, 29 patients were males while 22 were females, with ratio of 1.32:1. Female patients' mean age was 50.18 years while male patients' mean age was 52.71 years, with statistically nonsignificant difference between them. Functional rehabilitation was the main purpose of choosing dental implants in more than 90% of the subjects. Diameter of 3.75 mm was the shortest implants to be placed in the present study, whereas in terms of length, 8.5 mm was the shortest length of dental implant used in the present study. Tooth area in which maximum implants were placed in our study was 36 tooth region. Maximum implants were placed in Type II bone quality ( n = 38). Implants installed in the mandible were clamped more efficiently than implants placed in the maxilla ( P < 0.001). The difference of average STAI-State subscore before and after the surgery was statistically significant ( P < 0.05; significant). Mandibular dental implants show more clamping (torque) than maxillary dental implants.

  5. Real-time observation of fluctuations in a driven-dissipative quantum many-body system undergoing a phase transition

    Science.gov (United States)

    Donner, Tobias

    2015-03-01

    A Bose-Einstein condensate whose motional degrees of freedom are coupled to a high-finesse optical cavity via a transverse pump beam constitutes a dissipative quantum many-body system with long range interactions. These interactions can induce a structural phase transition from a flat to a density-modulated state. The transverse pump field simultaneously represents a probe of the atomic density via cavity- enhanced Bragg scattering. By spectrally analyzing the light field leaking out of the cavity, we measure non-destructively the dynamic structure factor of the fluctuating atomic density while the system undergoes the phase transition. An observed asymmetry in the dynamic structure factor is attributed to the coupling to dissipative baths. Critical exponents for both sides of the phase transition can be extracted from the data. We further discuss our progress in adding strong short-range interactions to this system, in order to explore Bose-Hubbard physics with cavity-mediated long-range interactions and self-organization in lower dimensions.

  6. Establishing an individual dosing system for patients undergoing interventional transcatheter arterial embolization: Radiochromic film and Monte Carlo simulation

    International Nuclear Information System (INIS)

    Tsai, Hui-Yu; Lai, Pei-Ling; Li, Yang-Ying; Tyan, Yeu-Sheng

    2011-01-01

    Less invasive imaging-guided vascular interventions with fluoroscopy and digital subtraction angiography have recently become widespread and have been successfully used for treating various diseases. However, interventional fluoroscopy procedures may present deterministic and stochastic radiation risks. The International Commission on Radiological Protection (ICRP) and the Food and Drug Administration have requested identifying procedures that may involve patient doses greater than the recommended thresholds. In this study, radiochromic dosimetric media, known as self-developing films, and measurement-based Monte Carlo simulations were used to establish an interventional radiology dosing system for individual patients undergoing interventional transcatheter arterial embolization. The peak skin dose, evaluated from the entrance surface dose distribution, was 21% less than the cumulated dose reported from the console. A 3D dose map incorporated into CT images was established. The organ doses and effective doses for individual patients were evaluated using this dosing system. This system could be applied very well to other fluoroscopic or interventional procedures for patient dose management.

  7. Systemic assessment of patients undergoing dental implant surgeries: A trans- and post-operative analysis

    Directory of Open Access Journals (Sweden)

    Sanjay Byakodi

    2017-01-01

    Full Text Available Background: Procedure-related and patient-related factors influence the prognosis of dental implants to a major extent. Hence, we aimed to evaluate and analyze various systemic factors in patients receiving dental implants. Materials and Methods: Fifty-one patients were included in the study, in which a total of 110 dental implants were placed. Complete examination of the subjects was done before and after placement of dental implants. Implant surgery was planned, and osseointegrated dental implants were placed in the subjects. Postoperative evaluation of the dental implant patients was done after 3 weeks. Anxiety levels were determined using State-Trait Anxiety Inventory (STAI questionnaire on the surgery day and after 1 week of surgery. The participant describes how they feel at the moment by responding to twenty items as follows: (1 absolutely not, (2 slightly, (3 somewhat, or (4 very much. All the results were recorded and statistical analyzed by SPSS software. Results: Out of 51, 29 patients were males while 22 were females, with ratio of 1.32:1. Female patients' mean age was 50.18 years while male patients' mean age was 52.71 years, with statistically nonsignificant difference between them. Functional rehabilitation was the main purpose of choosing dental implants in more than 90% of the subjects. Diameter of 3.75 mm was the shortest implants to be placed in the present study, whereas in terms of length, 8.5 mm was the shortest length of dental implant used in the present study. Tooth area in which maximum implants were placed in our study was 36 tooth region. Maximum implants were placed in Type II bone quality (n = 38. Implants installed in the mandible were clamped more efficiently than implants placed in the maxilla (P < 0.001. The difference of average STAI-State subscore before and after the surgery was statistically significant (P < 0.05; significant. Conclusion: Mandibular dental implants show more clamping (torque than maxillary

  8. Normalization references for USEtoxTM-based toxic impact categories: North American and European economic systems

    DEFF Research Database (Denmark)

    Laurent, Alexis; Lautier, Anne; Rosenbaum, Ralph K.

    2011-01-01

    economic regions, North America and Europe, to calculate normalization references for the three currently-modelled USEtoxTM-based impact categories, i.e. freshwater ecotoxicity, human toxicity, divided into cancer effects and non-cancer effects. Base years for the references are 2004 for Europe and 2006...... coverage of organics in both the inventory and the CF databases. With respect to the intended global character of the USEtoxTM model, different approaches to determine normalization references of other economic systems (e.g. Asia or world) are discussed in relation to these findings. Overall, we thus...... recommend the use of the provided set of normalization references for USEtoxTM, but we also advocate 1) to perform an update as soon as a more comprehensive inventory can be obtained and as soon as characterization factors for metals are revised; 2) to consider extension to other economic systems in order...

  9. Design and implementation of predictive filtering system for current reference generation of active power filter

    Energy Technology Data Exchange (ETDEWEB)

    Kilic, Tomislav; Milun, Stanko; Petrovic, Goran [FESB University of Split, Faculty of Electrical Engineering, Machine Engineering and Naval Architecture, R. Boskovica bb, 21000, Split (Croatia)

    2007-02-15

    The shunt active power filters are used to attenuate the harmonic currents in power systems by injecting equal but opposite compensating currents. Successful control of the active filters requires an accurate current reference. In this paper the current reference determination based on predictive filtering structure is presented. Current reference was obtained by taking the difference of load current and its fundamental harmonic. For fundamental harmonic determination with no time delay a combination of digital predictive filter and low pass filter is used. The proposed method was implemented on a laboratory prototype of a three-phase active power filter. The algorithm for current reference determination was adapted and implemented on DSP controller. Simulation and experimental results show that the active power filter with implemented predictive filtering structure gives satisfactory performance in power system harmonic attenuation. (author)

  10. Assessment of the periodontal health status in patients undergoing orthodontic treatment with fixed appliances and Invisalign system

    Science.gov (United States)

    Lu, Haili; Tang, Haifang; Zhou, Tian; Kang, Na

    2018-01-01

    Abstract Background: At present, many scholars have studied the periodontal health status of patients undergoing orthodontic treatment with fixed appliances and invisalign. However, those results are inconsistent. Therefore, we conducted this meta-analysis, and then provide reference for clinical treatment. Methods: Most databases, such as the Cochrane Library, EMBASE, PubMed, Medline, Chinese Biomedical Literature Database, CNKI, and Wan Fang Data were retrieved for related articles from the establishment of the database to October 2017. Meanwhile, we also searched the references of the related literatures manually, in order to increase the included literatures. Two researchers screened the related literatures according to the inclusion criteria and exclusion criteria. Stata 12.0 software was used for data analysis, and results are estimated by odds ratio (OR) and 95% confidence interval (CI). Results: Finally, 7 articles, including 368 patients, were included into our meta-analysis. Meta-analysis results showed that there was no statistically significant difference of gingival index (GI) and sulcus probing depth (SPD) status between the invisalign group and the control group, including at 1, 3, and 6 months (all P > .05). When compared with the control group, the invisalign group presented a lower plaque index (PLI) and sulcus bleeding index (SBI) status at 1 month (OR = −0.53, 95% CI: −0.89 to −0.18; OR = −0.44, 95% CI: −0.70 to −0.19, respectively), 3 months (OR = −0.69, 95% CI: −1.12 to −0.27; OR = −0.49, 95% CI: −0.93 to −0.05, respectively), and 6 months (OR = −0.91, 95% CI: −1.47 to −0.35; OR = −0.40, 95% CI: −0.63 to −0.07, respectively). Subgroup analysis showed that the SPD status was lower in the invisalign group at 6 months when measured the teeth using Ramfjord index (OR = −0.74, 95% CI: −1.35 to −0.12). However, there was no statistically significant difference between the 2

  11. Performance Guaranteed Inertia Emulation forDiesel-Wind System Feed Microgrid via ModelReference Control

    Energy Technology Data Exchange (ETDEWEB)

    Melin, Alexander M. [ORNL; Zhang, Yichen [University of Tennessee, Knoxville (UTK), Department of Electrical Engineering and Computer Science; Djouadi, Seddik [University of Tennessee, Knoxville (UTK), Department of Electrical Engineering and Computer Science; Olama, Mohammed M. [ORNL

    2017-04-01

    In this paper, a model reference control based inertia emulation strategy is proposed. Desired inertia can be precisely emulated through this control strategy so that guaranteed performance is ensured. A typical frequency response model with parametrical inertia is set to be the reference model. A measurement at a specific location delivers the information of disturbance acting on the diesel-wind system to the referencemodel. The objective is for the speed of the diesel-wind system to track the reference model. Since active power variation is dominantly governed by mechanical dynamics and modes, only mechanical dynamics and states, i.e., a swing-engine-governor system plus a reduced-order wind turbine generator, are involved in the feedback control design. The controller is implemented in a three-phase diesel-wind system feed microgrid. The results show exact synthetic inertia is emulated, leading to guaranteed performance and safety bounds.

  12. Water Quality in Small Community Distribution Systems. A Reference Guide for Operators

    Science.gov (United States)

    The U.S. Environmental Protection Agency (EPA) has developed this reference guide to assist the operators and managers of small- and medium-sized public water systems. This compilation provides a comprehensive picture of the impact of the water distribution system network on dist...

  13. Restoration of the orbital aesthetic subunit with the thoracodorsal artery system of flaps in patients undergoing radiation therapy.

    Science.gov (United States)

    Chanowski, Eric J P; Casper, Keith A; Eisbruch, Avraham; Heth, Jason A; Marentette, Lawrence J; Prince, Mark E; Moyer, Jeffrey S; Chepeha, Douglas B

    2013-10-01

    Objectives To demonstrate the advantages of the thoracodorsal artery scapular tip autogenous transplant (Tdast) for patients requiring restoration of the orbital aesthetic subunit. Design Prospective case series. Setting Tertiary center. Participants Ten patients (M:F,6:4) with a mean age of 56 years (range, 21 to 78 years) underwent restoration of the orbital aesthetic subunit and radiation therapy between 2001 and 2008. Main Outcome Measures The two reconstructive advantages of the thoracodorsal artery system of flaps for orbital reconstruction are a long pedicle and the suitability of the scapula tip to meet the three-dimensional requirements of the orbit. Patients were assessed 1 year or more after treatment for cosmetic outcome, work status, and socialization. Results Eight of 10 patients benefited from the three-dimensional nature of the scapula tip bone and 7 of 10 avoided vein grafting. Four of five evaluable patients reported "frequently" socializing outside their home. Four of five evaluable patients working before undergoing their treatment were able to return to work posttreatment. Seven of nine patients with postoperative photographs had minimal or no facial contour deformity. Conclusions The Tdast can restore orbital contour without osteotomy, and the thoracodorsal artery system of flaps has a long vascular pedicle that reduces vein grafting. Patients have an acceptable cosmetic result and return to preoperative work status and socialization.

  14. Environmental systems analysis of biogas systems-Part II: The environmental impact of replacing various reference systems

    International Nuclear Information System (INIS)

    Boerjesson, Pal; Berglund, Maria

    2007-01-01

    This paper analyses the overall environmental impact when biogas systems are introduced and replace various reference systems for energy generation, waste management and agricultural production. The analyses are based on Swedish conditions using a life-cycle perspective. The biogas systems included are based on different combinations of raw materials and final use of the biogas produced (heat, power and transportation fuel). A general conclusion is that biogas systems normally lead to environmental improvements, which in some cases are considerable. This is often due to indirect environmental benefits of changed land use and handling of organic waste products (e.g. reduced nitrogen leaching, emissions of ammonia and methane), which often exceed the direct environmental benefits achieved when fossil fuels are replaced by biogas (e.g. reduced emissions of carbon dioxide and air pollutants). Such indirect benefits are seldom considered when biogas is evaluated from an environmental point of view. The environmental impact from different biogas systems can, however, vary significantly due to factors such as the raw materials utilised, energy service provided and reference system replaced

  15. The System For Co-Reference Resolution For Slovenian Texts Analysis and Possibilities of its Use

    Directory of Open Access Journals (Sweden)

    Peter Holozan

    2015-10-01

    Full Text Available Co-reference resolution is an important part of language technologies, but has not yet been developed for Slovenian. There are various types of co-references and the paper focuses on anaphora resolution of personal pronouns. Seven methods, used in combination, were used; the most important one is based on activation. First results are promising, but for more extensive evaluation, Slovenian corpus with marked examples is needed. Co-reference resolution was used in the question answering system Crammer, which can, as a result, answer more questions than before, because it can replace personal pronouns. At the same time, some other improvement were added to Crammer, e.g. answering to individual words and phrases and answering to declarative sentences. Added was also generation of long answers to questions with interrogative particles. Co-reference resolution also improved working of Presis machine translation, especially for determining of gender of pronouns and for disambiguation of attributive subordinate clauses.

  16. Data reference and retrieval system for Richton Dome, Mississippi: annual status report for fiscal year 1982

    International Nuclear Information System (INIS)

    1983-06-01

    The Geologic Data Base for Richton Dome, Mississippi, was updated and expanded in FY 82 to support National Waste Terminal Storage characterization studies. The existing data base, consisting of references, maps, remote sensing data, and well-boring information, was inventoried to catalog the data acquired during previous studies. This catalog is maintained on Ertec's in-house computer. Bibliographies of selected documents were reviewed and commercial data bases were searched to identify additional references pertinent to future geologic characterization studies to be added to the data base. In addition to the references, selected preliminary safety analysis report sections and associated reports for nuclear generating stations, oil and gas well completion records, and US Geological Survey System 2000 hydrologic data were obtained for specific areas of Mississippi and Alabama. These additional data and references provide a comprehensive and current data base for Richton Dome

  17. Semiclassical neutral atom as a reference system in density functional theory.

    Science.gov (United States)

    Constantin, Lucian A; Fabiano, E; Laricchia, S; Della Sala, F

    2011-05-06

    We use the asymptotic expansions of the semiclassical neutral atom as a reference system in density functional theory to construct accurate generalized gradient approximations (GGAs) for the exchange-correlation and kinetic energies without any empiricism. These asymptotic functionals are among the most accurate GGAs for molecular systems, perform well for solid state, and overcome current GGA state of the art in frozen density embedding calculations. Our results also provide evidence for the conjointness conjecture between exchange and kinetic energies of atomic systems.

  18. A STUDY ON DETERMINING THE REFERENCE SPREADING SEQUENCES FOR A DS/CDMACOMMUNICATION SYSTEM

    Directory of Open Access Journals (Sweden)

    Cebrail ÇİFTLİKLİ

    2002-02-01

    Full Text Available In a direct sequence/code division multiple access (DS/CDMA system, the role of the spreading sequences (codes is crucial since the multiple access interference (MAI is the main performance limitation. In this study, we propose an accurate criterion which enables the determination of the reference spreading codes which yield lower bit error rates (BER's in a given code set for a DS/CDMA system using despreading sequences weighted by stepping chip waveforms. The numerical results show that the spreading codes determined by the proposed criterion are the most suitable codes for using as references.

  19. Functional representation for the grand partition function of a multicomponent system of charged particles: Correlation functions of the reference system

    Directory of Open Access Journals (Sweden)

    O.V.Patsahan

    2006-01-01

    Full Text Available Based on the method of collective variables (CV with a reference system, the exact expression for the functional of the grand partition function of a m-component ionic model with charge and size asymmetry is found. Particular attention is paid to the n-th particle correlation functions of the reference system which is presented as a m-component system of "colour" hard spheres of the same diameter. A two-component model is considered in more detail. In this case the recurrence formulas for the correlation functions are found. A general case of a m-component inhomogeneous system of the "colour" hard spheres is also analysed.

  20. RF Phase Reference Distribution System for the TESLA Technology Based Projects

    CERN Document Server

    Czuba, K; Romaniuk, R S

    2013-01-01

    Since many decades physicists have been building particle accelerators and usually new projects became more advanced, more complicated and larger than predecessors. The importance and complexity of the phase reference distribution systems used in these accelerators have grown significantly during recent years. Amongst the most advanced of currently developed accelerators are projects based on the TESLA technology. These projects require synchronization of many RF devices with accuracy reaching femtosecond levels over kilometre distances. Design of a phase reference distribution system fulfilling such requirements is a challenging scientific task. There are many interdisciplinary problems which must be solved during the system design. Many, usually negligible issues, may became very important in such system. Furthermore, the design of a distribution system on a scale required for the TESLA technology based projects is a new challenge and there is almost no literature sufficiently covering this subject. This th...

  1. An Excel-Based System to Manage Radiation Safety for the Family of Patients Undergoing 131I Therapy.

    Science.gov (United States)

    Steward, Palmer G

    2017-06-01

    The purpose of this study was to develop spreadsheet workbooks that assist in the radiation safety counseling of 131 I therapy patients and their families, providing individualized guidelines that avoid imposing overly conservative restrictions on family members and others. Methods: The mathematic model included biphasic patient radionuclide retention. The extrathyroidal component was a cylindric volume with a diameter corresponding to the patient's size and included patient self-absorption, whereas the thyroidal component was a point source whose transmission was reduced by self-absorption. A separate model in which the thyroid, extrathyroid, and bladder compartments fed serially from one to the next was developed to depict the radionuclide levels within the patient and to estimate the activity entering the environment at each urination. Results: The system was organized into a set of 4 workbooks: the first to be used with ablation patients prepared using thyrogen, the second with ablation patients prepared by deprivation, the third with hyperthyroid patients, and the fourth with the unusual hyperthyroid patient who finds the restrictions to be oppressive and returns 5-10 d after administration for a measurement and reassessment. The workbooks evaluated the radiation field strength external to the patient and indicated restrictions based on selected dose limits. To assist physicians in suggesting contamination precautions, the workbooks also evaluated the radioactivity present within the patient and the estimated discharge into the environment as a function of time. Conclusion: The workbooks that were developed assist the radiation safety counselor in individualizing radiation protection procedures for the family of patients undergoing 131 I therapy. The workbook system avoids overly conservative assumptions while permitting selection of appropriate dose limits for each individual. © 2017 by the Society of Nuclear Medicine and Molecular Imaging.

  2. Evaluation of the impact of writing exercises interventions on quality of life in patients with psoriasis undergoing systemic treatments.

    Science.gov (United States)

    Tabolli, S; Naldi, L; Pagliarello, C; Sampogna, F; di Pietro, C; Spagnoli, A; Abeni, D

    2012-12-01

    Emotional writing is a short-term psychological intervention that has been successfully used in several controlled studies. The overall objective of the study was to test the efficacy of Pennebaker's emotional writing intervention in patients with psoriasis treated with systemic therapy. A randomized controlled trial was conducted in seven clinical centres in Italy, over a 2-year period. The main outcome measures were the psoriasis area and severity index and the Physician Global Assessment, as well as generic and dermatology-specific quality of life questionnaires. Such outcomes were measured at 4 weeks, and 6 and 12 months from baseline. The project recruitment time was 12 months, and the total follow-up time for each individual was also 12 months. In total, 202 patients were enrolled and assessed at baseline, 67 of whom completed all three follow-up visits. The writing exercise had little or no effect on patients with psoriasis who were undergoing systemic treatment. In the Generalized Estimating Equations models no statistically significant differences were observed in the Pennebaker intervention group vs. the control group. In subgroup analysis for health status, small effects in favour of patients assigned to the Pennebaker group were documented at the end of the study in women, in overweight individuals, in patients under treatment with biological drugs, and on the Physical Component Summary of the Short Form of the Medical Outcomes Study Questionnaire. The Pennebaker and control groups had similar changes over time for practically all the outcome variables, and also when considering all observations and adjusting for all the variables of interest. The longitudinal analysis confirmed that the intervention had little or no effect on the variables of interest. The implementation of writing exercises requires a careful and ad hoc organization, including dedicated spaces for the writing itself. © 2012 The Authors. BJD © 2012 British Association of

  3. Reference-tracking feedforward control design for linear dynamical systems through signal decomposition

    NARCIS (Netherlands)

    Kasemsinsup, Y.; Romagnoli, R.; Heertjes, M.F.; Weiland, S.; Butler, H.

    2017-01-01

    In this work, we study a novel approach towards the reference-tracking feedforward control design for linear dynamical systems. By utilizing the superposition property and exploiting signal decomposition together with a quadratic optimization process, we obtain a feedforward design procedure for

  4. Reference Models of Information Systems Constructed with the use of Technologies of Cloud Calculations

    Directory of Open Access Journals (Sweden)

    Darya Sergeevna Simonenkova

    2013-09-01

    Full Text Available The subject of the research is analysis of various models of the information system constructed with the use of technologies of cloud calculations. Analysis of models is required for constructing a new reference model which will be used for develop a security threats model.

  5. Nouns referring to tools and natural objects differentially modulate the motor system.

    Science.gov (United States)

    Gough, Patricia M; Riggio, Lucia; Chersi, Fabian; Sato, Marc; Fogassi, Leonardo; Buccino, Giovanni

    2012-01-01

    While increasing evidence points to a critical role for the motor system in language processing, the focus of previous work has been on the linguistic category of verbs. Here we tested whether nouns are effective in modulating the motor system and further whether different kinds of nouns - those referring to artifacts or natural items, and items that are graspable or ungraspable - would differentially modulate the system. A Transcranial Magnetic Stimulation (TMS) study was carried out to compare modulation of the motor system when subjects read nouns referring to objects which are Artificial or Natural and which are Graspable or Ungraspable. TMS was applied to the primary motor cortex representation of the first dorsal interosseous (FDI) muscle of the right hand at 150 ms after noun presentation. Analyses of Motor Evoked Potentials (MEPs) revealed that across the duration of the task, nouns referring to graspable artifacts (tools) were associated with significantly greater MEP areas. Analyses of the initial presentation of items revealed a main effect of graspability. The findings are in line with an embodied view of nouns, with MEP measures modulated according to whether nouns referred to natural objects or artifacts (tools), confirming tools as a special class of items in motor terms. Additionally our data support a difference for graspable versus non graspable objects, an effect which for natural objects is restricted to initial presentation of items. Copyright © 2011 Elsevier Ltd. All rights reserved.

  6. Towards a reference ontology of complex economic exchanges for Accounting Information Systems

    NARCIS (Netherlands)

    Blums, Ivar; Weigand, Hans; Matthes, Flores; Mendling, Jan; Rinderle-Ma, Stefanie

    Although the field of Accounting Information Systems (AIS) has a long tradition, there is still a lack of a widely adopted conceptualization. The Unified Foundational Ontology (UFO) and its Services sub- ontology (UFO-S) are regarded as grounding the engineering of a reference ontology for AIS. The

  7. A new method of 3-D cephalometry Part I: the anatomic Cartesian 3-D reference system.

    NARCIS (Netherlands)

    Swennen, G.R.J.; Schutyser, F.A.C.; Barth, E.L.; Groeve, P. De; Mey, A. De

    2006-01-01

    The purpose of this study was to present a new innovative three-dimensional (3-D) cephalometric method. Part I deals with the set-up and validation of a voxel-based semi-automatic 3-D cephalometric reference system. The CT data (DICOM 3.0 files) of 20 control patients with normal skeletal

  8. The disposal of Canada's nuclear fuel waste: postclosure assessment of a reference system

    International Nuclear Information System (INIS)

    Goodwin, B.W.; McConnell, D.B.; Andres, T.H.

    1994-01-01

    The concept for disposal of Canada's nuclear fuel waste is based on a vault located deep in plutonic rock of the Canadian Shield. We document in this report a method to assess the long-term impacts of a disposal facility for nuclear fuel waste. The assessment integrates relevant information from engineering design studies, site investigations, laboratory studies, expert judgment and detailed mathematical analyses to evaluate system performance in terms of safety criteria, guidelines and standards. The method includes the use of quantitative tools such as the Systems Variability Analysis computer Code (SYVAC) to deal with parameter uncertainty and the use of reasoned arguments based on well-established scientific principles. We also document the utility of the method by describing its application to a hypothetical implementation of the concept called the reference disposal system. The reference disposal system generally conforms to the overall characteristics of the concept, except we have made some specific site and design choices so that the assessment would be more realistic. To make the reference system more representative of a real system, we have used the geological observations of the AECL's Whiteshell Research Area located near Lac du Bonnet, Manitoba, to define the characteristics of the geosphere and the groundwater flow system. This research area has been subject to more than a decade of geological and hydrological studies. The analysis of the reference disposal system provides estimates of radiological and chemical toxicity impacts on members of a critical group and estimates of possible impacts on the environment. The latter impacts include estimates of radiation dose to nonhuman organisms. Other quantitative analyses examine the use of derived constraints to improve the margin of safety, the effectiveness of engineered and natural barriers, and the sensitivity of the results to influential features, events, and processes of the reference disposal

  9. A reference dosimetric system for dose interval of radiotherapy based on alanine/RPE

    International Nuclear Information System (INIS)

    Rodrigues Junior, Orlando; Galante, Ocimar L.; Campos, Leticia L.

    2001-01-01

    This work describes the development of a reference dosimetric system based on alanine/EPR for radiotherapy dose levels. Currently the IPEN is concluding a similar system for the dose range used for irradiation of products, 10-10 5 Gy. The objective of this work is to present the efforts towards to improve the measure accuracy for doses in the range between 1-10 Gy. This system could be used as reference by radiotherapy services, as much in the quality control of the equipment, as for routine accompaniment of more complex handling where the total doses can reach some grays. The system uses alanine as detector and electronic paramagnetic resonance - EPR as measure technique. To reach accuracy better than 5% mathematical studies on the best optimization of the EPR spectrometer parameters and methods for the handling of the EPR sign are discussed. (author)

  10. EUPOS - Satellite multifunctional system of reference stations in Central and Eastern Europe

    Science.gov (United States)

    Sledzinski, J.

    2003-04-01

    The European project EUPOS (European Position Determination System) of establishment of a system of multifunctional satellite reference stations in Central and Eastern Europe is described in the paper. Fifteen countries intend to participate in the project: Bulgaria, Croatia, Czech Republic, Estonia, Germany, Hungary, Latvia, Lithuania, Macedonia, Poland, Romania, Russia, Serbia, Slovak Republic and Slovenia. One common project will be prepared for all countries, however it will include the existing or developed infrastructure in particular countries. The experiences of establishing and operating of the German network SAPOS as well as experiences gained by other countries will be used. The European network of stations will be compatible with the system SAPOS and future European system Galileo. The network of reference stations will provide signal for both positioning of the geodetic control points and for land, air and marine navigation. Several levels of positioning accuracy will be delivered.

  11. Initial testing of a neutron activation analysis system by analysing standard reference materials

    International Nuclear Information System (INIS)

    Suhaimi Hamzah; Roslan Idris; Abdul Khalik Haji Wood; Che Seman Mahmood; Abdul Rahim Mohamad Noor.

    1983-01-01

    This paper describes the data acquisition and processing system in our laboratories (ND6600), the methods of activation analysis and the results obtained from our analysis of IAEA standard reference material (SL-l lake sediments and NBS coal ash 1632a). These standards were analysed in order to check the capability of the system, which was designed in such a way as to enable the user to independently collect and process data from multiple radiation detectors. (author)

  12. Climate mitigation comparison of woody biomass systems with the inclusion of land-use in the reference fossil system

    International Nuclear Information System (INIS)

    Haus, S.; Gustavsson, L.; Sathre, R.

    2014-01-01

    While issues of land-use have been considered in many direct analyses of biomass systems, little attention has heretofore been paid to land-use in reference fossil systems. Here we address this limitation by comparing forest biomass systems to reference fossil systems with explicit consideration of land-use in both systems. We estimate and compare the time profiles of greenhouse gas (GHG) emission and cumulative radiative forcing (CRF) of woody biomass systems and reference fossil systems. A life cycle perspective is used that includes all significant elements of both systems, including GHG emissions along the full material and energy chains. We consider the growth dynamics of forests under different management regimes, as well as energy and material substitution effects of harvested biomass. We determine the annual net emissions of CO 2 , N 2 O and CH 4 for each system over a 240-year period, and then calculate time profiles of CRF as a proxy measurement of climate change impact. The results show greatest potential for climate change mitigation when intensive forest management is applied in the woody biomass system. This methodological framework provides a tool to help determine optimal strategies for managing forests so as to minimize climate change impacts. The inclusion of land-use in the reference system improves the accuracy of quantitative projections of climate benefits of biomass-based systems. - Highlights: • We analyze the dynamics of GHG emissions from woody biomass and fossil systems. • With a life cycle perspective, we account for forest land-use in both systems. • Replacing more carbon intensive fossil fuels gives greater climate benefit. • Increasing the intensity of forest management gives greater climate benefit. • Methodological choices in defining temporal system boundaries are important

  13. The Absolute Stability Analysis in Fuzzy Control Systems with Parametric Uncertainties and Reference Inputs

    Science.gov (United States)

    Wu, Bing-Fei; Ma, Li-Shan; Perng, Jau-Woei

    This study analyzes the absolute stability in P and PD type fuzzy logic control systems with both certain and uncertain linear plants. Stability analysis includes the reference input, actuator gain and interval plant parameters. For certain linear plants, the stability (i.e. the stable equilibriums of error) in P and PD types is analyzed with the Popov or linearization methods under various reference inputs and actuator gains. The steady state errors of fuzzy control systems are also addressed in the parameter plane. The parametric robust Popov criterion for parametric absolute stability based on Lur'e systems is also applied to the stability analysis of P type fuzzy control systems with uncertain plants. The PD type fuzzy logic controller in our approach is a single-input fuzzy logic controller and is transformed into the P type for analysis. In our work, the absolute stability analysis of fuzzy control systems is given with respect to a non-zero reference input and an uncertain linear plant with the parametric robust Popov criterion unlike previous works. Moreover, a fuzzy current controlled RC circuit is designed with PSPICE models. Both numerical and PSPICE simulations are provided to verify the analytical results. Furthermore, the oscillation mechanism in fuzzy control systems is specified with various equilibrium points of view in the simulation example. Finally, the comparisons are also given to show the effectiveness of the analysis method.

  14. Development of picture quality monitoring system for IPTV service based on the reduced reference framework

    Science.gov (United States)

    Sugimoto, Osamu; Kawada, Ryoichi; Koike, Atsushi

    2006-01-01

    The authors developed a software-based realtime IPTV monitoring system based on Reduced Reference framework, and evaluated the proposed system. One of the quality issues of the IPTV service is the picture quality degradation caused by packet loss. The proposed system precisely estimates the PSNR of the corrupted received picture by extracting and comparing image features from transmission and receiver side. Computer simulations show that PSNR estimation with a 0.945 correlation coefficient at a data channel bitrate of 36kbps is possible using the proposed system.

  15. System for effluent treatment with particular reference to the reuse of the water

    Energy Technology Data Exchange (ETDEWEB)

    Rolke, O.E.

    1979-01-01

    A system for effluent treatment with particular reference to the reuse of the water consisted of biological treatment, flocculation, filtration, activated carbon adsorption and ion exchange. Such a multistage system is needed to treat wastewaters from coal gasification and coke-oven plants since the effluents, derived from cooling water for scrubbers, waste heat boilers, and heat exchangers, contains high levels of phenols, fatty acids, ammonia, suspended tar oil, and coal particles. A pilot plant, which has been built based on the system, will produce water of sufficient quality for reuse as cooling water. It is hoped that cooling systems for coal gasification plants can be 90% closed circuit.

  16. Effect of pretreatment psoas muscle mass on survival for patients with unresectable pancreatic cancer undergoing systemic chemotherapy.

    Science.gov (United States)

    Ishii, Noriko; Iwata, Yoshinori; Nishikawa, Hiroki; Enomoto, Hirayuki; Aizawa, Nobuhiro; Ishii, Akio; Miyamoto, Yuho; Yuri, Yukihisa; Hasegawa, Kunihiro; Nakano, Chikage; Nishimura, Takashi; Yoh, Kazunori; Sakai, Yoshiyuki; Ikeda, Naoto; Takashima, Tomoyuki; Takata, Ryo; Iijima, Hiroko; Nishiguchi, Shuhei

    2017-11-01

    To the best of our knowledge, there are few previous studies that have investigated the effect of decreased skeletal muscle mass (DSMM) on survival in patients with unresectable advanced pancreatic cancer (APC) who are undergoing systemic chemotherapy. Thus, the present study aimed to investigate the impact of DSMM, as determined by the psoas muscle index (PMI) following computed tomography and prior to systemic chemotherapy, on the outcomes of patients with unresectable APC (n=61). The primary endpoint used was the overall survival (OS) rate. The OS rates in the PMI-High group (exceeds the median PMI value in each gender) were retrospectively compared with those in the PMI-Low group (below the median PMI value in each gender), and factors associated with OS were investigated using univariate and multivariate analyses. The study cohort included 31 male and 30 female patients with a median age of 72 years, 13 of whom were stage IVA, and 48 were stage IVB. The median PMI in males was 4.3 cm 2 /m 2 (range, 1.6-8.2 cm 2 /m 2 ), while that in females was 2.3 cm 2 /m 2 (range, 0.7-6.1 cm 2 /m 2 ). The proportion of patients with performance status 0 in the PMI-High group was significantly high, compared with that in the PMI-Low group [83.3% (25/30) vs. 58.1% (18/31); P=0.0486]. Body mass index in the PMI-High group was significantly higher compared with that in the PMI-Low group (P=0.0154). The 1-year cumulative survival rate was 43.3% in the PMI-High group and 12.9% in the PMI-Low group (P=0.0027). Following multivariate analysis, PMI (P=0.0036), prothrombin time (P=0.0044) and carbohydrate antigen 19-9 (P=0.0451) were identified to be significant predictors of OS. In conclusion, DSMM, as determined by the PMI, could be a significant predictor of prognosis in patients with unresectable APC who are receiving systemic chemotherapy.

  17. LibraryH3lp: A New Flexible Chat Reference System

    Directory of Open Access Journals (Sweden)

    Pam Sessoms

    2008-09-01

    Full Text Available LibraryH3lp is an integrated IM and web chat system designed specifically for Virtual Reference services in libraries. The software was designed for, and is currently used by, a night-time chat reference collaboraton between several large academic libraries. LibraryH3lp is designed for the workflow of chat reference, supporting multiple simultaneous operators and routing to queues of operators in a particular service area. It also supports web page embeddable chat 'widgets', as well as simultaneous gateways to multiple IM protocols. This article discusses the motivation for the development of the software, and provides an overview of LibraryH3lp's features and technical architecture. Parts of LibraryH3lp are available as open source. The complete application is available as a low-cost hosted service, and will eventually be available to be licensed for local hosting.

  18. Study on the System Requirements and Structures of Mailbox Declaration System for Reference Pyroprocessing Facility in the ROK

    International Nuclear Information System (INIS)

    Jeon, Jong Kyu

    2011-01-01

    The mailbox declaration system applied for the implementation of Safeguards at the Reference Pyroprocessing Facility (REPF) plays important role to support the declared information provided from Near-Real Time Accountancy (NRTA) and provides reference data to confirm the measurement results generated from the Unattended Monitoring System (UMS) for the purposes of verification and real-time monitoring of the movements and changes of nuclear materials (NM) at the processes in the REPF. In order to install and operate the mailbox declaration system at the REPF, this study focused on the operation, security, transmission of confidential information, procedure for transmission of mailbox declaration system as system requirements, and structure of mailbox declaration system to review the declared information through the mailbox by the national authority and to transmit the revised information to the IAEA

  19. Cross-sectional imaging to evaluate the extent of regional nodal disease in breast cancer patients undergoing neoadjuvant systemic therapy

    Energy Technology Data Exchange (ETDEWEB)

    Anderson, Tara L., E-mail: anderson.tara@mayo.edu [Mayo Clinic, Department of Radiology, 200 First Street SW, Rochester, MN, 55905 (United States); Glazebrook, Katrina N., E-mail: glazebrook.katrina@mayo.edu [Mayo Clinic, Department of Radiology, 200 First Street SW, Rochester, MN, 55905 (United States); Murphy, Brittany L., E-mail: murphy.brittany@mayo.edu [Mayo Clinic, Department of Surgery, 200 First Street SW, Rochester, MN, 55905 (United States); Viers, Lyndsay D., E-mail: viers.lyndsay@mayo.edu [Mayo Clinic, Department of Radiology, 200 First Street SW, Rochester, MN, 55905 (United States); Hieken, Tina J, E-mail: hieken.tina@mayo.edu [Mayo Clinic, Department of Surgery, 200 First Street SW, Rochester, MN, 55905 (United States)

    2017-04-15

    Purpose: Cross-sectional imaging often is performed in breast cancer patients undergoing neoadjuvant systemic therapy (NST) and may identify level III axillary and extra-axillary nodal disease. Our aim was to investigate associations of radiologic nodal staging with pathological N (pN) stage at operation and to explore how this might aid surgical and radiotherapy treatment planning. Materials and methods: With IRB approval, we reviewed pre-treatment breast MRI, PET/CT, and CT imaging and clinicopathologic data on 348 breast cancer patients with imaging available for review undergoing NST followed by operation at our institution 1/2008-9/2013. We defined abnormal lymph node findings on MRI, CT, and PET/CT to include cortical thickening, FDG-avidity and loss of fatty hilum. Patients were assigned a radiologic nodal (rN) stage based on imaging findings. Statistical analysis was performed using JMP 10.1 software Results: Pre-NST imaging included axillary ultrasound in 338 patients (97%), breast MRI in 305 (88%) and PET/CT or CT in 215 (62%). 213 patients (61%) were biopsy-proven axillary lymph node-positive (LN+) pre-treatment. cT stage was T1 in 9%, T2 in 49%, T3 in 29%, T4 in 12%; median tumor size was 4 cm. Pre-treatment rN stage across all the patients was rN0 in 86 (25%), rN1 in 173 (50%), and rN3 in 89 (26%). rN3 disease included level III axillary, supraclavicular and suspicious internal mammary lymph nodes in 47 (53%), 32 (37%) and 45 (52%), respectively. Of patients LN+ at diagnosis, 78 (37%) were rN3. After NST, 162 patients (47%) were node-positive at operation with a median (mean) of 3 (5.9 ± 0.4) positive lymph nodes including 128 of 213 (60%) LN+ at diagnosis. Pre-NST rN stage correlated with the likelihood and extent of axillary disease at operation, p = 0.002. Fifty four of 89 rN3 patients (61%) were node-positive at operation with a median (mean) of 5 (8 ± 1) positive nodes. rN3 patients had larger nodal metastases (median 9 vs 6 mm) and more

  20. Cross-sectional imaging to evaluate the extent of regional nodal disease in breast cancer patients undergoing neoadjuvant systemic therapy

    International Nuclear Information System (INIS)

    Anderson, Tara L.; Glazebrook, Katrina N.; Murphy, Brittany L.; Viers, Lyndsay D.; Hieken, Tina J

    2017-01-01

    Purpose: Cross-sectional imaging often is performed in breast cancer patients undergoing neoadjuvant systemic therapy (NST) and may identify level III axillary and extra-axillary nodal disease. Our aim was to investigate associations of radiologic nodal staging with pathological N (pN) stage at operation and to explore how this might aid surgical and radiotherapy treatment planning. Materials and methods: With IRB approval, we reviewed pre-treatment breast MRI, PET/CT, and CT imaging and clinicopathologic data on 348 breast cancer patients with imaging available for review undergoing NST followed by operation at our institution 1/2008-9/2013. We defined abnormal lymph node findings on MRI, CT, and PET/CT to include cortical thickening, FDG-avidity and loss of fatty hilum. Patients were assigned a radiologic nodal (rN) stage based on imaging findings. Statistical analysis was performed using JMP 10.1 software Results: Pre-NST imaging included axillary ultrasound in 338 patients (97%), breast MRI in 305 (88%) and PET/CT or CT in 215 (62%). 213 patients (61%) were biopsy-proven axillary lymph node-positive (LN+) pre-treatment. cT stage was T1 in 9%, T2 in 49%, T3 in 29%, T4 in 12%; median tumor size was 4 cm. Pre-treatment rN stage across all the patients was rN0 in 86 (25%), rN1 in 173 (50%), and rN3 in 89 (26%). rN3 disease included level III axillary, supraclavicular and suspicious internal mammary lymph nodes in 47 (53%), 32 (37%) and 45 (52%), respectively. Of patients LN+ at diagnosis, 78 (37%) were rN3. After NST, 162 patients (47%) were node-positive at operation with a median (mean) of 3 (5.9 ± 0.4) positive lymph nodes including 128 of 213 (60%) LN+ at diagnosis. Pre-NST rN stage correlated with the likelihood and extent of axillary disease at operation, p = 0.002. Fifty four of 89 rN3 patients (61%) were node-positive at operation with a median (mean) of 5 (8 ± 1) positive nodes. rN3 patients had larger nodal metastases (median 9 vs 6 mm) and more

  1. CCF analysis of high redundancy systems safety/relief valve data analysis and reference BWR application

    International Nuclear Information System (INIS)

    Mankamo, T.; Bjoere, S.; Olsson, Lena

    1992-12-01

    Dependent failure analysis and modeling were developed for high redundancy systems. The study included a comprehensive data analysis of safety and relief valves at the Finnish and Swedish BWR plants, resulting in improved understanding of Common Cause Failure mechanisms in these components. The reference application on the Forsmark 1/2 reactor relief system, constituting of twelve safety/relief lines and two regulating relief lines, covered different safety criteria cases of reactor depressurization and overpressure protection function, and failure to re close sequences. For the quantification of dependencies, the Alpha Factor Model, the Binomial Probability Model and the Common Load Model were compared for applicability in high redundancy systems

  2. Camera Calibration of Stereo Photogrammetric System with One-Dimensional Optical Reference Bar

    International Nuclear Information System (INIS)

    Xu, Q Y; Ye, D; Che, R S; Qi, X; Huang, Y

    2006-01-01

    To carry out the precise measurement of large-scale complex workpieces, accurately calibration of the stereo photogrammetric system has becoming more and more important. This paper proposed a flexible and reliable camera calibration of stereo photogrammetric system based on quaternion with one-dimensional optical reference bar, which has three small collinear infrared LED marks and the lengths between these marks have been precisely calibration. By moving the optical reference bar at a number of locations/orientations over the measurement volume, we calibrate the stereo photogrammetric systems with the geometric constraint of the optical reference bar. The extrinsic parameters calibration process consists of linear parameters estimation based on quaternion and nonlinear refinement based on the maximum likelihood criterion. Firstly, we linear estimate the extrinsic parameters of the stereo photogrameetric systems based on quaternion. Then with the quaternion results as the initial values, we refine the extrinsic parameters through maximum likelihood criterion with the Levenberg-Marquardt Algorithm. In the calibration process, we can automatically control the light intensity and optimize the exposure time to get uniform intensity profile of the image points at different distance and obtain higher S/N ratio. The experiment result proves that the calibration method proposed is flexible, valid and obtains good results in the application

  3. DESIGN OF ROBUST NAVIGATION AND STABILIZATION LOOPS OF PRECISION ATTITUDE AND HEADING REFERENCE SYSTEM

    Directory of Open Access Journals (Sweden)

    Olha Sushchenko

    2017-11-01

    Full Text Available Purpose: The paper focuses on problems of design of robust precision attitude and heading reference systems, which can be applied in navigation of marine vehicles. The main goal is to create the optimization procedures for design of navigation and stabilization loops of the multimode gimballed system. The optimization procedure of the navigation loop design is based on the parametric robust H2/H∞-optimization. The optimization procedure of the stabilization loop design is based on the robust structural H∞-synthesis. Methods: To solve the given problem the methods of the robust control system theory and optimization methods are used. Results: The kinematical scheme of the precision gimballed attitude and heading reference system is represented. The parametrical optimization algorithm taking into consideration features of the researched system is given. Method of the mixed sensitivity relative to the researched system design is analyzed. Coefficients of the control laws of navigation loops are obtained based on optimization procedure providing compromise between accuracy and robustness. The robust controller of the stabilization loop was developed based on robust structural synthesis using method of the mixed sensitivity. Simulation of navigation and stabilization processes is carried out. Conclusions: The represented results prove efficiency of the proposed procedures, which can be useful for design of precision navigation systems of the moving vehicles.

  4. Fluorescence tracers as a reference for pesticide transport in wetland systems

    Science.gov (United States)

    Lange, Jens; Passeport, Elodie; Tournebize, Julien

    2010-05-01

    Two different fluorescent tracers, Uranine (UR) and Sulforhodamine (SRB), were injected as a pulse into surface flow wetlands. Tracer breakthrough curves were used to document hydraulic efficiencies, peak attenuation and retention capacities of completely different wetland systems. The tracers were used as a reference to mimic photolytic decay (UR) and sorption (SRB) of contaminants, since a real herbicide (Isoproturon, IPU) was injected in parallel to UR and SRB. Analysis costs limited IPU sampling frequency and single samples deviated from the tracer breakthrough curves. Still, a parallel behavior of IPU and SRB could be observed in totally different wetland systems, including underground passage through drainage lines. Similar recovery rates for IPU and SRB confirmed this observation. Hence, SRB was found to be an appropriate reference tracer to mimic the behavior of mobile pesticides (low KOC, without degradation) in wetland systems and the obtained wetland characteristics for SRB may serve as an indication for contaminant retention. Owing to the properties of IPU, the obtained results should be treated as worst case scenarios for highly mobile pesticides. A comparison of six different wetland types suggested that non-steady wetland systems with large variation in water level may temporally store relatively large amounts of tracers (contaminants), partly in areas that are not continuously saturated. This may lead to an efficient attenuation of peak concentrations. However, when large parts of these systems are flushed by natural storm events, tracers (contaminants) may be re-mobilized. In steady systems vegetation density and water depth were found to be the most important factors for tracer/contaminant retention. Illustrated by SRB, sorption on sediments and vegetation was a quick, almost instantaneous process which lead to considerable tracer losses even at high flow velocities and short contact times. Shallow systems with dense vegetation appeared to be the

  5. Calibration of a multi-beam Laser System by using a TLS-generated Reference

    Directory of Open Access Journals (Sweden)

    M. Gordon

    2013-10-01

    Full Text Available Rotating multi-beam LIDARs mounted on moving platforms have become very successful for many applications such as autonomous navigation, obstacle avoidance or mobile mapping. To obtain accurate point coordinates, a precise calibration of such a LIDAR system is required. For the determination of the corresponding parameters we propose a calibration scheme which exploits the information of 3D reference point clouds captured by a terrestrial laser scanning (TLS device. It is assumed that the accuracy of this point clouds is considerably higher than that from the multi-beam LIDAR and that the data represent faces of man-made objects at different distances. After extracting planes in the reference data sets, the point-plane-incidences of the measured points and the reference planes are used to formulate the implicit constraints. We inspect the Velodyne HDL-64E S2 system as the best-known representative for this kind of sensor system. The usability and feasibility of the calibration procedure is demonstrated with real data sets representing building faces (walls, roof planes and ground. Beside the improvement of the point accuracy by considering the calibration results, we test the significance of the parameters related to the sensor model and consider the uncertainty of measurements w.r.t. the measured distances. The Velodyne returns two kinds of measurements – distances and encoder angles. To account for this, we perform a variance component estimation to obtain realistic standard deviations for the observations.

  6. Implementation of a system for external audits beam radiation therapy in terms of reference no

    International Nuclear Information System (INIS)

    Alonso Samper, Jose Luis; Dominguez, Lourdes; Alert Silva, Jose; Alfonso Laguardia, Rodolfo; Larrinaga Cortina, Eduardo; Garcia Yip, Fernando; Rodriguez Machado, Jorge; Morales Lopez, Jorge Luis; Silvestre Patallo, Ileana

    2009-01-01

    This paper presents our experience in implementing a external audit system for radiotherapy beam in no reference conditions with the use of CIRS and a summary of the measurements with him made.This paper presents our experience in implementing a external audit system for radiotherapy beam in no reference conditions with the use of CIRS and a summary of the measurements with him made. Centers were audited with external beam high-energy Co-60, 6 MV and 15 MV and were considered 4 treatment planning systems (TPS): AMEPLAN, Theraplan Plus, Precise Plan and MIRS to calculate doses prescribed in each test case. All measurements were acquired by the audit team using the anthropomorphic phantom CIRS, Semiflex chamber PTW 31010 and PTW electrometer STATES. The implementation and development of the external audits of beams radiotherapy in terms of 'no reference' has brought an improvement in both clinical aspects of treatment and the radiation safety and the quality control, has given us greater confidence and for this reason we believe has become essential. (Author)

  7. Development of reference problems for neutron capture therapy treatment planning systems

    International Nuclear Information System (INIS)

    Albritton, J.R.; Kiger, W.S. III

    2006-01-01

    Currently, 5 different treatment planning systems (TPSs) are or have been used in clinical trials of Neutron Capture Therapy (NCT): MacNCTPlan, NCTPlan, BNCT Rtpe, SERA, and JCDS. This paper describes work performed to comprehensively test and compare 4 of these NCT treatment planning systems in order to facilitate the pooling of patient data from the different clinical sites for analysis of the clinical results as well as to provide an important quality assurance tool for existing and future TPSs. Two different phantoms were used to evaluate the planning systems: the modified Snyder head phantom and a large water-filled box, similar to that used in the International Dosimetry Exchange for NCT. The comparison of the resulting dose profile, isodose contours, and dose volume histograms to reference calculations performed with the Monte Carlo radiation transport code MCNP5 yielded many interesting differences. Each of the planning systems deviated from the reference calculations, with the newer systems (i.e., SERA and NCTPlan) most often yielding better agreement than their predecessors (i.e., BNCT Rtpe and MacNCTPlan). The combination of simple phantoms and sources with more complicated and realistic planning conditions has produced a well-rounded and useful suite of test problems for NCT treatment planning system analysis. (author)

  8. 1-GWh diurnal load-leveling superconducting magnetic energy storage system reference design

    International Nuclear Information System (INIS)

    Hassenzahl, W.V.; Rogers, J.D.

    1979-01-01

    A point reference design has been completed for a 1-GWh Superconducting Magnetic Energy Storage system. The system is for electric utility dirunal load leveling; however, such a device will function to meet much faster power demands including dynamic stabilization. The study has explored several concepts of design not previously considered in the same detail as treated here. Because the study is for a point design, optimization in all respects is not complete. The study examines aspects of the coil design; superconductor supported off of the dewar shell; the dewar shell, its configuration and stresses; the underground excavation and related construction for holding the superconducting coil and its dewar; the helium refrigeration system; the electrical converter system; the vacuum system; the guard coil; and the costs. The report is a condensation of the more comprehensive study which is in the process of being printed

  9. A reference system for the measurement of low-strength magnetic flux density

    International Nuclear Information System (INIS)

    Fiorillo, F.; Durin, G.F.; Rocchino, L.

    2006-01-01

    Magnetic flux density standards traceable to the SI units have been developed at IEN-INRIM, by which dissemination for general measurement and testing activities can be pursued. The reference system covers a range of values extending from μ 0 H∼1T to μ 0 H∼10μT and is centered on the use of NMR magnetometers, calibrated coils, and stable current sources. The relative measuring uncertainty of the system is shown to increases with decreasing the field strength value and it is estimated to range between a few 10 -6 and some 10 -3

  10. Decision support systems in nuclear emergencies: A scenario-based comparison of domestic and reference tools

    International Nuclear Information System (INIS)

    Vamanu, D.; Slavnicu, S. D.; Slavnicu, E.; Vamanu, B.

    2004-01-01

    The article reports selective results of a comparison between RODOS - an emerging decision support system for the management of nuclear emergencies in Europe developed by an international research consortium under EEC aegis, and a resident software package developed and maintained for similar purposes at IFIN-HH, Bucharest. Reproducible similarity patterns obtained in the output data distributions provide for simple normalising procedures that may ensure convergent radiological assessments. When properly consolidated on a sufficient scenario casuistry, such procedures could lend a certain resilience to domestic decision support tools over the interim lead time required by the full implementation of RODOS, or other major league, internationally accepted reference systems. (authors)

  11. New reference object for metrological performance testing of industrial CT systems

    DEFF Research Database (Denmark)

    Müller, Pavel; Hiller, Jochen; Cantatore, Angela

    2012-01-01

    This paper presents a new reference object, so called “CT ball plate”, used for metrological performance testing of industrial CT systems, and discusses both the calibration procedure using a tactile coordinate measuring machine and the first results carried out using an industrial CT scanner....... This artefact can be used to determine several characteristics of the CT system like, probing errors of spheres, length measuring errors between sphere centers, measurement errors in the whole CT volume and effects in connection with image artefacts....

  12. A Nonlinear Attitude Estimator for Attitude and Heading Reference Systems Based on MEMS Sensors

    DEFF Research Database (Denmark)

    Wang, Yunlong; Soltani, Mohsen; Hussain, Dil muhammed Akbar

    2016-01-01

    In this paper, a nonlinear attitude estimator is designed for an Attitude Heading and Reference System (AHRS) based on Micro Electro-Mechanical Systems (MEMS) sensors. The design process of the attitude estimator is stated with detail, and the equilibrium point of the estimator error model...... the problems in previous research works. Moreover, the estimation of MEMS gyroscope bias is also inclueded in this estimator. The designed nonlinear attitude estimator is firstly tested in simulation environment and then implemented in an AHRS hardware for further experiments. Finally, the attitude estimation...

  13. Integrated security systems design a complete reference for building enterprise-wide digital security systems

    CERN Document Server

    Norman, Thomas L

    2014-01-01

    Integrated Security Systems Design, 2nd Edition, is recognized as the industry-leading book on the subject of security systems design. It explains how to design a fully integrated security system that ties together numerous subsystems into one complete, highly coordinated, and highly functional system. With a flexible and scalable enterprise-level system, security decision makers can make better informed decisions when incidents occur and improve their operational efficiencies in ways never before possible. The revised edition covers why designing an integrated security system is essential a

  14. Disturbance rejection performance analyses of closed loop control systems by reference to disturbance ratio.

    Science.gov (United States)

    Alagoz, Baris Baykant; Deniz, Furkan Nur; Keles, Cemal; Tan, Nusret

    2015-03-01

    This study investigates disturbance rejection capacity of closed loop control systems by means of reference to disturbance ratio (RDR). The RDR analysis calculates the ratio of reference signal energy to disturbance signal energy at the system output and provides a quantitative evaluation of disturbance rejection performance of control systems on the bases of communication channel limitations. Essentially, RDR provides a straightforward analytical method for the comparison and improvement of implicit disturbance rejection capacity of closed loop control systems. Theoretical analyses demonstrate us that RDR of the negative feedback closed loop control systems are determined by energy spectral density of controller transfer function. In this manner, authors derived design criteria for specifications of disturbance rejection performances of PID and fractional order PID (FOPID) controller structures. RDR spectra are calculated for investigation of frequency dependence of disturbance rejection capacity and spectral RDR analyses are carried out for PID and FOPID controllers. For the validation of theoretical results, simulation examples are presented. Copyright © 2014 ISA. Published by Elsevier Ltd. All rights reserved.

  15. Decision support systems in nuclear emergencies: harmonizing domestic and reference tools

    International Nuclear Information System (INIS)

    Vamanu, D.; Mateescu, Gh.; Berinde, A.; Slavnicu, D.; Acasandrei, V.; Slavnicu, E.

    2001-01-01

    The paper addresses the issue of securing the compatibility and inter-operability of computer packages designed to perform as decision support tools in the management of radiological emergencies, over the transition times towards the implementation and uniform acceptance and uniform acceptance of internationally-shared reference tools such as the European Union's RODOS (Real Time On-Line Decision Support System for Off-Site Nuclear Emergencies in Europe). One submits that a harmonization between the currently operational, domestic, and the reference tool can be contemplated, based on extensive code comparison and benchmarking. A case in point is presented, paralleling selected RODOS applications on simulated abnormal nuclear events, and the concurrent application of a resident software package, NOTEPAD, developed to emulate RODOS-wise function at IFIH-HH Bucharest. The reproducible similarity may make domestic decision support system (DSS) facilities useful as both practical tools and factors promoting the emergency preparedness awareness, during the interim time laps till the full development and deployment of RODOS as a reference DSS in Europe. (authors)

  16. Normalization of NDVI from Different Sensor System using MODIS Products as Reference

    International Nuclear Information System (INIS)

    Wenxia, Gan; Liangpei, Zhang; Wei, Gong; Huanfeng, Shen

    2014-01-01

    Medium Resolution NDVI(Normalized Difference Vegetation Index) from different sensor systems such as Landsat, SPOT, ASTER, CBERS and HJ-1A/1B satellites provide detailed spatial information for studies of ecosystems, vegetation biophysics, and land cover. Limitation of sensor designs, cloud contamination, and sensor failure highlighted the need to normalize and integrate NDVI from multiple sensor system in order to create a consistent, long-term NDVI data set. In this paper, we used a reference-based method for NDVI normalization. And present an application of this approach which covert Landsat ETM+ NDVI calculated by digital number (NDVI DN ) to NDVI calculated by surface reflectance (NDVI SR ) using MODIS products as reference, and different cluster was treated differently. Result shows that this approach can produce NDVI with highly agreement to NDVI calculated by surface reflectance from physical approaches based on 6S (Second Simulation of the satellite Signal in the Solar Spectrum). Although some variability exists, the cluster specified reference based approach shows considerable potential for NDVI normalization. Therefore, NDVI products in MODIS era from different sources can be combined for time-series analysis, biophysical parameter retrievals, and other downstream analysis

  17. Reference spent fuel and its characteristics for the concept development of a deep geological disposal system

    International Nuclear Information System (INIS)

    Kang, C. H.; Choi, J. W.; Ko, W. I.; Lee, Y. M.; Park, J. H.; Hwang, Y. S.; Kim, S. K.

    1997-09-01

    The total amount of spent fuel arisen from the nuclear power plant to be planned by 2010 at the basis of the long-term power development plan announced by MOTIE (Ministry of Trade, Industry and Energy Resource) in 1995 is estimated to derive the disposal capacity of a deep geological repository is derived. The reference spent fuel whose characteristics could be planned is selected by analysing the characteristic data such as initial enrichment, discharge burnup, geometry, dimension, gross weight, etc. Also isotopic concentration, radioactivity, decay heat, hazard index and radiation intensity of a reference spent fuel are quantitatively identified and summarized in order to apply in the concept developing works of a deep geological disposal system. (author). 12 refs., 24 tabs., 14 figs

  18. Reference spent fuel and its characteristics for the concept development of a deep geological disposal system

    Energy Technology Data Exchange (ETDEWEB)

    Kang, C. H.; Choi, J. W.; Ko, W. I.; Lee, Y. M.; Park, J. H.; Hwang, Y. S.; Kim, S. K.

    1997-09-01

    The total amount of spent fuel arisen from the nuclear power plant to be planned by 2010 at the basis of the long-term power development plan announced by MOTIE (Ministry of Trade, Industry and Energy Resource) in 1995 is estimated to derive the disposal capacity of a deep geological repository is derived. The reference spent fuel whose characteristics could be planned is selected by analysing the characteristic data such as initial enrichment, discharge burnup, geometry, dimension, gross weight, etc. Also isotopic concentration, radioactivity, decay heat, hazard index and radiation intensity of a reference spent fuel are quantitatively identified and summarized in order to apply in the concept developing works of a deep geological disposal system. (author). 12 refs., 24 tabs., 14 figs.

  19. Fast breeder reactor reference system classification for the ENEA data bank

    International Nuclear Information System (INIS)

    Righini, R.

    1988-01-01

    This report contains the Reference System Classification (RSC) of fast breeder reactors: it provides a functional system breakdown of the reactor. For each system the following important characteristics are reported: the main function, the mode of operation, its location in the reactor, the main interface system, its main components and the component working environment (fluid and/or atmosphere type). The RSC represent a basic step in organizing the ENEA data bank for the registration and processing of reliability data on typical fast reactor components; it provides a functional component breakdown and represent a plant-unique identification in the process of omogenization of event-data coming from different reactors. In this report it was tried to take into account different generations of nuclear power plants, different plant layouts and solutions: in particular loop and pool reactors are separately treated

  20. Pathway to 2022: The Ongoing Modernization of the United States National Spatial Reference System

    Science.gov (United States)

    Stone, W. A.; Caccamise, D.

    2017-12-01

    The National Oceanic and Atmospheric Administration's National Geodetic Survey (NGS) mission is "to define, maintain and provide access to the National Spatial Reference System (NSRS) to meet our nation's economic, social, and environmental needs." The NSRS is an assemblage of geophysical and geodetic models, tools, and data, with the most-visible components being the North American Datum of 1983 (NAD83) and the North American Vertical Datum of 1988 (NAVD88), which together provide a consistent spatial reference framework for myriad geospatial applications and positioning requirements throughout the United States. The NGS is engaged in an ongoing and comprehensive multi-year project of modernizing the NSRS, a makeover necessitated by technological developments and user accuracy requirements, all with a goal of providing a modern, accurate, accessible, and globally aligned national positioning framework exploiting the substantial power and utility of the Global Navigation Satellite System - of both today and tomorrow. The modernized NSRS will include four new-generation geometric terrestrial reference frames (replacing NAD83) and a technically unprecedented geopotential datum (replacing NAVD88), all to be released in 2022 (anticipated). This poster/presentation will describe the justification for this modernization effort and will update the status and planned evolution of the NSRS as 2022 draws ever closer. Also discussed will be recent developments, including the publication of "blueprint" documents addressing technical details of various facets of the modernized NSRS and a continued series of public Geospatial Summits. Supporting/ancillary projects such as Gravity for the Redefinition of the American Vertical Datum (GRAV-D), which will result in the generation of a highly accurate gravimetric geoid - or definitional reference surface (zero elevation) - for the future geopotential datum, and Geoid Slope Validation Surveys (GSVS), which are exploring the achievable

  1. Development of Power Controller System based on Model Reference Adaptive Control for a Nuclear Reactor

    International Nuclear Information System (INIS)

    Mohd Sabri Minhat; Izhar Abu Hussin; Ridzuan Abdul Mutalib

    2014-01-01

    The Reactor TRIGA PUSPATI (RTP)-type TRIGA Mark II was installed in the year 1982. The Power Controller System (PCS) or Automated Power Controller System (APCS) is very important for reactor operation and safety reasons. It is a function of controlled reactivity and reactor power. The existing power controller system is under development and due to slow response, low accuracy and low stability on reactor power control affecting the reactor safety. The nuclear reactor is a nonlinear system in nature, and it is power increases continuously with time. The reactor parameters vary as a function of power, fuel burnup and control rod worth. The output power value given by the power control system is not exactly as real value of reactor power. Therefore, controller system design is very important, an adaptive controller seems to be inevitable. The method chooses is a linear controller by using feedback linearization, for example Model Reference Adaptive Control. The developed APCS for RTP will be design by using Model Reference Adaptive Control (MRAC). The structured of RTP model to produce the dynamic behaviour of RTP on entire operating power range from 0 to 1MWatt. The dynamic behavior of RTP model is produced by coupling of neutronic and thermal-hydraulics. It will be developed by using software MATLAB/Simulink and hardware module card to handle analog input signal. A new algorithm for APCS is developed to control the movement of control rods with uniformity and orderly for RTP. Before APCS test to real plant, simulation results shall be obtained from RTP model on reactor power, reactivity, period, control rod positions, fuel and coolant temperatures. Those data are comparable with the real data for validation. After completing the RTP model, APCS will be tested to real plant on power control system performance by using real signal from RTP including fail-safe operation, system reliable, fast response, stability and accuracy. The new algorithm shall be a satisfied

  2. Moving to a Modernized Height Reference System in Canada: Rationale, Status and Plans

    Science.gov (United States)

    Veronneau, M.; Huang, J.

    2007-05-01

    A modern society depends on a common coordinate reference system through which geospatial information can be interrelated and exploited reliably. For height measurements this requires the ability to measure mean sea level elevations easily, accurately, and at the lowest possible cost. The current national reference system for elevations, the Canadian Geodetic Vertical Datum of 1928 (CGVD28), offers only partial geographic coverage of the Canadian territory and is affected by inaccuracies that are becoming more apparent as users move to space- based technologies such as GPS. Furthermore, the maintenance and expansion of the national vertical network using spirit-levelling, a costly, time consuming and labour intensive proposition, has only been minimally funded over the past decade. It is now generally accepted that the most sustainable alternative for the realization of a national vertical datum is a gravimetric geoid model. This approach defines the datum in relation to an ellipsoid, making it compatible with space-based technologies for positioning. While simplifying access to heights above mean sea level all across the Canadian territory, this approach imposes additional demands on the quality of the geoid model. These are being met by recent and upcoming space gravimetry missions that have and will be measuring the Earth`s gravity field with increasing and unprecedented accuracy. To maintain compatibility with the CGVD28 datum materialized at benchmarks, the current first-order levelling can be readjusted by constraining geoid heights at selected stations of the Canadian Base Network. The new reference would change CGVD28 heights of benchmarks by up to 1 m across Canada. However, local height differences between benchmarks would maintain a relative precision of a few cm or better. CGVD28 will co-exist with the new height reference as long as it will be required, but it will undoubtedly disappear as benchmarks are destroyed over time. The adoption of GNSS

  3. A reference model for model-based design of critical infrastructure protection systems

    Science.gov (United States)

    Shin, Young Don; Park, Cheol Young; Lee, Jae-Chon

    2015-05-01

    Today's war field environment is getting versatile as the activities of unconventional wars such as terrorist attacks and cyber-attacks have noticeably increased lately. The damage caused by such unconventional wars has also turned out to be serious particularly if targets are critical infrastructures that are constructed in support of banking and finance, transportation, power, information and communication, government, and so on. The critical infrastructures are usually interconnected to each other and thus are very vulnerable to attack. As such, to ensure the security of critical infrastructures is very important and thus the concept of critical infrastructure protection (CIP) has come. The program to realize the CIP at national level becomes the form of statute in each country. On the other hand, it is also needed to protect each individual critical infrastructure. The objective of this paper is to study on an effort to do so, which can be called the CIP system (CIPS). There could be a variety of ways to design CIPS's. Instead of considering the design of each individual CIPS, a reference model-based approach is taken in this paper. The reference model represents the design of all the CIPS's that have many design elements in common. In addition, the development of the reference model is also carried out using a variety of model diagrams. The modeling language used therein is the systems modeling language (SysML), which was developed and is managed by Object Management Group (OMG) and a de facto standard. Using SysML, the structure and operational concept of the reference model are designed to fulfil the goal of CIPS's, resulting in the block definition and activity diagrams. As a case study, the operational scenario of the nuclear power plant while being attacked by terrorists is studied using the reference model. The effectiveness of the results is also analyzed using multiple analysis models. It is thus expected that the approach taken here has some merits

  4. The disposal of Canada's nuclear fuel waste: comments on the postclosure assessment of a reference system

    International Nuclear Information System (INIS)

    Allan, C.J.; Goodwin, B.W.

    1996-07-01

    Canada, like other countries, is developing technology for disposal of its nuclear fuel waste , based on the concept of geological disposal in stable plutonic rock of the Canadian Shield. The choice of methods, materials, and designs for a disposal system will ultimately be made on the basis of safety, taking into account the characteristics of the specific site on which the facility is to be developed, costs and practicality. As part of its work in developing the technology for the disposal of Canada's nuclear fuel waste, AECL analyzed the performance of a hypothetical disposal facility that incorporates specific design choices for the engineered barriers and that assumes a specific geological setting. This system, comprising the disposal facility and the geological setting, and the results of the performance analysis, is described in an Environmental Impact Statement that AECL submitted in 1994 and in a Primary Reference for the EIS 'The Disposal of Canada's Nuclear Fuel Waste: Postclosure Assessment of a Reference System.' The performance analysis was not intended to be a general proof of the safety of disposal, but rather it presents a safety analysis of one specific system to illustrate the postclosure assessment methodology and to demonstrate that safety could be achieved for the system in question. Although the design of the disposal facility analyzed and the geological setting have specific features, the results obtained from the safety analysis can, however, be used to provide considerable insight into the performance of the various components that comprise the multibarrier geological disposal system. Moreover, the results can show how changes in the performance of specific components can affect the overall performance of the system. This report discusses these aspects of the postclosure analysis. (author)

  5. New reference trajectory optimization algorithm for a flight management system inspired in beam search

    Directory of Open Access Journals (Sweden)

    Alejandro MURRIETA-MENDOZA

    2017-08-01

    Full Text Available With the objective of reducing the flight cost and the amount of polluting emissions released in the atmosphere, a new optimization algorithm considering the climb, cruise and descent phases is presented for the reference vertical flight trajectory. The selection of the reference vertical navigation speeds and altitudes was solved as a discrete combinatory problem by means of a graph-tree passing through nodes using the beam search optimization technique. To achieve a compromise between the execution time and the algorithm’s ability to find the global optimal solution, a heuristic methodology introducing a parameter called “optimism coefficient was used in order to estimate the trajectory’s flight cost at every node. The optimal trajectory cost obtained with the developed algorithm was compared with the cost of the optimal trajectory provided by a commercial flight management system(FMS. The global optimal solution was validated against an exhaustive search algorithm(ESA, other than the proposed algorithm. The developed algorithm takes into account weather effects, step climbs during cruise and air traffic management constraints such as constant altitude segments, constant cruise Mach, and a pre-defined reference lateral navigation route. The aircraft fuel burn was computed using a numerical performance model which was created and validated using flight test experimental data.

  6. Comparison of the TLDA with the Nanodrop and the reference Qubit system

    Energy Technology Data Exchange (ETDEWEB)

    O' Neill, M; Arthure, K; Riedel, S; McMillan, ND [Drop Technology Ltd., Tallaght Business Park, Whitestown, Dublin 24 (Ireland); McPartlin, J, E-mail: martina.oneill@droptechnology.com [Vitamin Research Unit, Department of Clinical Medicine, Sir Patrick Duns Laboratory, CPL, St. James' s Hospital, Dublin 8 (Ireland)

    2011-08-17

    The TLDA (transmitted light drop analyser) is a new microvolume UV-visible drop spectrophotometer new to the market. Assays were compared between a TLDA, NanoDrop and the Qubit system which is based on the gold standard for DNA assay, PicoGreen. The evaluation was carried out by the Trinity Biobank in St. James Hospital, Dublin on Buccal swabs and Blood samples. The data is discussed in this paper. The Qubit system is seen as the reference method in most studies as this is believed to provide more accurate results than UV absorbance methods because it distinguishes between DNA, RNA, free nucleotides, and other contaminants. The Qubit system uses fluorescent dyes to measure the concentration of the molecule of interest. The results compare both the spectrophotometric methods against the Qubit fluorescence technique.

  7. On-board landmark navigation and attitude reference parallel processor system

    Science.gov (United States)

    Gilbert, L. E.; Mahajan, D. T.

    1978-01-01

    An approach to autonomous navigation and attitude reference for earth observing spacecraft is described along with the landmark identification technique based on a sequential similarity detection algorithm (SSDA). Laboratory experiments undertaken to determine if better than one pixel accuracy in registration can be achieved consistent with onboard processor timing and capacity constraints are included. The SSDA is implemented using a multi-microprocessor system including synchronization logic and chip library. The data is processed in parallel stages, effectively reducing the time to match the small known image within a larger image as seen by the onboard image system. Shared memory is incorporated in the system to help communicate intermediate results among microprocessors. The functions include finding mean values and summation of absolute differences over the image search area. The hardware is a low power, compact unit suitable to onboard application with the flexibility to provide for different parameters depending upon the environment.

  8. Software reference for SaTool - a Tool for Structural Analysis of Automated Systems

    DEFF Research Database (Denmark)

    Lorentzen, Torsten; Blanke, Mogens

    2004-01-01

    This software reference details the functions of SaTool – a tool for structural analysis of technical systems. SaTool is intended used as part of an industrial systems design cycle. Structural analysis is a graph-based technique where principal relations between variables express the system’s...... of the graph. SaTool makes analysis of the structure graph to provide knowledge about fundamental properties of the system in normal and faulty conditions. Salient features of SaTool include rapid analysis of possibility to diagnose faults and ability to make autonomous recovery should faults occur........ The list of such variables and functional relations constitute the system’s structure graph. Normal operation means all functional relations are intact. Should faults occur, one or more functional relations cease to be valid. In a structure graph, this is seen as the disappearance of one or more nodes...

  9. Anthology of the renin-angiotensin system: a one hundred reference approach to angiotensin II antagonists.

    Science.gov (United States)

    Ménard, J

    1993-04-01

    To provide a historical overview of the renin-angiotensin system as a guide to the introduction of a new therapeutic pathway, non-peptide inhibition of a angiotensin II. One hundred references were selected as a personal preference, for their originality or for their potential impact on medicine. This review raises the following questions for future research. (1) Will the long-term cardiovascular effects of angiotensin converting enzyme (ACE) inhibition, angiotensin II antagonism and renin inhibition be similar or not, and dependent or independent of blood pressure levels? (2) What are the local-regional interactions between vasoconstrictor and vasodilator systems, and does the renin-angiotensin system synchronize these regional hemodynamic regulatory mechanisms? (3) If hypertension is the result of an interaction between genetic and environmental factors, do proteins secreted through constitutive pathways contribute to the genetic abnormality (prorenin, angiotensinogen, ACE) while regulated secretion (renin) and other regulatory mechanisms (angiotensin II receptors) provide biological support for the environmental effects?

  10. Effect of long-lived containers on the postclosure performance of a reference disposal system

    International Nuclear Information System (INIS)

    Goodwin, B.W.; Hajas, W.C.; LeNeveu, D.M.

    1996-05-01

    The concept for disposal of Canada's nuclear fuel waste involves isolating the waste in corrosion-resistant containers emplaced in a scaled vault at a depth of 500 to 1000 m in plutonic rock of the Canadian Shield. The concept permits a choice of methods, materials, site locations, and designs. The technical feasibility of this concept and its impact on the environment and human health are summarized in an Environmental Impact Statement (AECL 1994a,b), supported by nine detailed reference documents (Davis et al. 1993; Davison et al. 1994a,b; Goodwin et al. 1994; Greber et al. 1994; Grondin et al. 1994; Johnson et al. 1994a,b; Simmons and Baumgartner 1994). In the assessment of the reference disposal system, we assumed the containers encapsulating the nuclear fuel waste were constructed from Grade-2 titanium. In this report, we investigate the effect of a different choice, and assume the use of long-lived containers constructed from materials such as high-purity copper or Grades-12 or -16 titanium alloys. These alternative materials would provide much longer periods of protection, based on the expectation that the only container failure mechanism, for times up to 10 5 a, involves initial fabrication defects. We explore the effects of long-lived containers for the same vault layout and orientation that were assumed for the reference disposal vault. We also explore effects for two less favourable situations, in which the vault is closer to a nearby fracture zone and in which the vault is extended to have emplacement rooms on both sides of the fracture zone. Our analyses use the probabilistic assessment computer code, SYVAC3-CC3, an acronym for SYstems Variability Analysis Code, generation 3. with a system model describing the Canadian Concept, generation 3, for the disposal of nuclear fuel waste. The input data for the code have been adjusted to approximate the expected protection characteristics of alternative container materials. (author). 31 refs., 1 tab., 16 figs

  11. Reference system architecture for trade promotion management: leveraging business intelligence technologies and decision support systems

    NARCIS (Netherlands)

    Balmus, Andra Bianca; Iacob, Maria Eugenia; van Sinderen, Marten J.; van Busschbach, Murk

    Working towards gaining competitive advantage and establishing stable relationships with their supply chain intermediaries, fast moving consumer goods companies are currently focusing their attention on intelligent, goal-based funds investment. Traditional trade promotion management systems (TPMS),

  12. Speed Estimation of Induction Motor Using Model Reference Adaptive System with Kalman Filter

    Directory of Open Access Journals (Sweden)

    Pavel Brandstetter

    2013-01-01

    Full Text Available The paper deals with a speed estimation of the induction motor using observer with Model Reference Adaptive System and Kalman Filter. For simulation, Hardware in Loop Simulation method is used. The first part of the paper includes the mathematical description of the observer for the speed estimation of the induction motor. The second part describes Kalman filter. The third part describes Hardware in Loop Simulation method and its realization using multifunction card MF 624. In the last section of the paper, simulation results are shown for different changes of the induction motor speed which confirm high dynamic properties of the induction motor drive with sensorless control.

  13. Computerized literature reference system: use of an optical scanner and optical character recognition software.

    Science.gov (United States)

    Lossef, S V; Schwartz, L H

    1990-09-01

    A computerized reference system for radiology journal articles was developed by using an IBM-compatible personal computer with a hand-held optical scanner and optical character recognition software. This allows direct entry of scanned text from printed material into word processing or data-base files. Additionally, line diagrams and photographs of radiographs can be incorporated into these files. A text search and retrieval software program enables rapid searching for keywords in scanned documents. The hand scanner and software programs are commercially available, relatively inexpensive, and easily used. This permits construction of a personalized radiology literature file of readily accessible text and images requiring minimal typing or keystroke entry.

  14. Disposable Miniaturized Screen‐Printed pH and Reference Electrodes for Potentiometric Systems

    DEFF Research Database (Denmark)

    Musa, Arnaud Emmanuel; del Campo, Francisco Javier; Abramova, Natalia

    2011-01-01

    This work describes the development of a miniaturized potentiometric system comprising a miniaturized quasi‐reference electrode (QRE) coupled to a solid‐state ion‐selective electrode (ISE) for the monitoring of pH. We describe the optimization of materials and fabrication processes including screen‐printing...... electrode) that can be used continuously for a period of not less than 7 days in aqueous solutions. Curing the Ag/AgCl pastes during 20 minutes at 120 °C after printing allowed the QREs to display excellent potential stability, as demonstrated by an open‐circuit‐potential standard deviation of ±1.2 mV over...

  15. Method of collective variables with reference system for the grand canonical ensemble

    International Nuclear Information System (INIS)

    Yukhnovskii, I.R.

    1989-01-01

    A method of collective variables with special reference system for the grand canonical ensemble is presented. An explicit form is obtained for the basis sixth-degree measure density needed to describe the liquid-gas phase transition. Here the author presents the fundamentals of the method, which are as follows: (1) the functional form for the partition function in the grand canonical ensemble; (2) derivation of thermodynamic relations for the coefficients of the Jacobian; (3) transition to the problem on an adequate lattice; and (4) obtaining of the explicit form for the functional of the partition function

  16. Reference reactor module for NASA's lunar surface fission power system

    Energy Technology Data Exchange (ETDEWEB)

    Poston, David I [Los Alamos National Laboratory; Kapernick, Richard J [Los Alamos National Laboratory; Dixon, David D [Los Alamos National Laboratory; Werner, James [INL; Qualls, Louis [ORNL; Radel, Ross [SNL

    2009-01-01

    Surface fission power systems on the Moon and Mars may provide the first US application of fission reactor technology in space since 1965. The Affordable Fission Surface Power System (AFSPS) study was completed by NASA/DOE to determine the cost of a modest performance, low-technical risk surface power system. The AFSPS concept is now being further developed within the Fission Surface Power (FSP) Project, which is a near-term technology program to demonstrate system-level TRL-6 by 2013. This paper describes the reference FSP reactor module concept, which is designed to provide a net power of 40 kWe for 8 years on the lunar surface; note, the system has been designed with technologies that are fully compatible with a Martian surface application. The reactor concept uses stainless-steel based. UO{sub 2}-fueled, pumped-NaK fission reactor coupled to free-piston Stirling converters. The reactor shielding approach utilizes both in-situ and launched shielding to keep the dose to astronauts much lower than the natural background radiation on the lunar surface. The ultimate goal of this work is to provide a 'workhorse' power system that NASA can utilize in near-term and future Lunar and Martian mission architectures, with the eventual capability to evolve to very high power, low mass systems, for either surface, deep space, and/or orbital missions.

  17. An update to the analysis of the Canadian Spatial Reference System

    Science.gov (United States)

    Ferland, R.; Piraszewski, M.; Craymer, M.

    2015-12-01

    The primary objective of the Canadian Spatial Reference System (CSRS) is to provide users access to a consistent geo-referencing infrastructure over the Canadian landmass. Global Navigation Satellite System (GNSS) positioning accuracy requirements ranges from meter level to mm level (e.g.: crustal deformation). The highest level of the Canadian infrastructure consist of a network of continually operating GPS and GNSS receivers, referred to as active control stations. The network includes all Canadian public active control stations, some bordering US CORS and Alaska stations, Greenland active control stations, as well as a selection of IGS reference frame stations. The Bernese analysis software is used for the daily processing and the combination into weekly solutions which form the basis for this analysis. IGS weekly final orbit, Earth Rotation parameters (ERP's) and coordinates products are used in the processing. For the more demanding users, the time dependant changes of station coordinates is often more important.All station coordinate estimates and related covariance information is used in this analysis. For each input solution, variance factor, translation, rotation and scale (and if needed their rates) or subsets of these are estimated. In the combination of these weekly solutions, station positions and velocities are estimated. Since the time series from the stations in these networks often experience changes in behavior, new (or reuse of) parameters are generally used in these situations. As is often the case with real data, unrealistic coordinates may occur. Automatic detection and removal of outliers is used in these cases. For the transformation, position and velocity parameters loose apriori estimates and uncertainties are provided. Alignment using the usual Helmert transformation to the latest IGb08 realization of ITRF is also performed during the adjustment.

  18. Development of the Korean Reference Vertical Disposal System Concept for Spent Fuels

    International Nuclear Information System (INIS)

    Lee, J.Y.; Cho, D.K.; Kim, S.G.; Choi, H.J.; Choi, J.W.; Hahn, P.S.

    2006-01-01

    The development of a deep geologic disposal system for the spent fuel from nuclear power plants has been carried out since this program was launched at 1997 in Korea. In ' this paper, a pre-conceptual design of the Korean Reference HLW Vertical disposal System (KRS-V1) is presented. Though no site for the underground repository has yet been specified in Korea, a generic site with granitic rock is considered for reference HLW repository design. Depth of the repository is assumed to be 500 meters. The repository consists of the disposal area, technical rooms with four shafts to connect them to the ground level in the controlled area and technical rooms with an access tunnel and three shafts to connect them to the ground level in the uncontrolled area. Disposal area consists of disposal tunnels, panel tunnels and a central tunnel. The repository will be excavated, operated and backfilled in several phases including an Underground Research Laboratory (URL) phase. The result of this preliminary conceptual design will be used for an evaluation of the feasibility, analyses of the long term safety, information for public communication and a cost estimation etc. (authors)

  19. Test reference years - meteorological bases for the technical simulation of heating systems and air-conditioning systems

    International Nuclear Information System (INIS)

    Perl, J.

    1991-01-01

    For the FRG (western part) for 12 regions with different climate test reference years (TRY) have been established. The TRYs are used for the simulation of the thermal behaviour of buildings, of the operation of heating and space avc systems, lighting control, solar plants as well as of comparable technical systems. A TRY is a collection of hourly data of important meterological parameters over a whole year. The TRYs include 14 meteorological parameters for temperature, humidity, wind, short- and long-wave radiation, atmospheric pressure, precipitation and description of the weather at that time. A TRY is to correspond to the characteristic weather conditions of the TRY region. (orig.) [de

  20. Terminological reference of a knowledge-based system: the data dictionary.

    Science.gov (United States)

    Stausberg, J; Wormek, A; Kraut, U

    1995-01-01

    The development of open and integrated knowledge bases makes new demands on the definition of the used terminology. The definition should be realized in a data dictionary separated from the knowledge base. Within the works done at a reference model of medical knowledge, a data dictionary has been developed and used in different applications: a term definition shell, a documentation tool and a knowledge base. The data dictionary includes that part of terminology, which is largely independent of a certain knowledge model. For that reason, the data dictionary can be used as a basis for integrating knowledge bases into information systems, for knowledge sharing and reuse and for modular development of knowledge-based systems.

  1. Preliminary measurements of the establishment of a quality control programme for the activimeter calibration reference system

    International Nuclear Information System (INIS)

    Martins, Elaine W.; Potiens, Maria da Penha A.

    2009-01-01

    The nuclear medicine techniques efficiency and safety depends on, beside other factors, a quality control programme, mainly regards to the nuclides activimeter utilization. The Calibration Laboratory of IPEN uses as a work standard, a tertiary standard system Capintec, calibrated at the Accredited Dosimetry Calibration Laboratory of the Medical radiation Research Center - University of Wisconsin. In this work, as preliminary measurements to establish a quality control programme for the activimeter calibration procedures, initially the repeatability and reproducibility (long term stability) tests were performed using a sealed check source of 133 Ba. Later on, to complete this quality control programme other check sources ( 137 Cs, 57 Co, 60 Co) will be used to perform the same tests. A series of 80 experiments of 10 measurements each has been carried out. The reference system showed a good behaviour to the repeatability test, considering the tolerance limits of 5%. The percent deviations of all tested sources in the activity measurements were lower 1% to 133 Ba. (author)

  2. Evaluation of the prognostic value of Okuda, Cancer of the Liver Italian Program, and Japan Integrated Staging systems for hepatocellular carcinoma patients undergoing radiotherapy

    International Nuclear Information System (INIS)

    Seong, Jinsil; Shim, Su Jung; Lee, Ik Jae; Han, Kwang Hyub; Chon, Chae Yoon; Ahn, Sang Hoon

    2007-01-01

    Purpose: The purpose of this study was to compare the validity of staging systems, as well as to identify the staging system with the best prognostic value, in hepatocellular carcinoma (HCC) patients treated with radiotherapy. Methods and Materials: From 1992 to 2003, a total of 305 patients undergoing radiotherapy for HCC were evaluated retrospectively. All patients were classified before radiation therapy by the following systems: tumor-node-metastasis (TNM), Okuda, Cancer of the Liver Italian Program (CLIP), and Japan Integrated Staging (JIS) score. Cumulative survival rates were obtained using the Kaplan-Meier method, and were statistically compared using the log-rank test. Results: Median survival time was 11 months. The 1-, 2-, 3-, 4-, and 5-year survival rates were 45.1%, 24.5%, 14.7%, 10.3%, and 6.4%, respectively. Significant differences in survival were observed between all TNM stages, between CLIP scores 2, 3 and 5, 6, as well as between JIS scores 1, 2, and 2, 3. Conclusions: Among the systems studied, the TNM staging approach appeared to be the best predictor of prognosis. Staging systems that reflect liver disease status (Okuda stage, CLIP, and JIS score) showed limitations in stratifying patients undergoing radiotherapy into different prognostic groups

  3. [Introduction of computerized anesthesia-recording systems and construction of comprehensive medical information network for patients undergoing surgery in the University of Tokyo Hospital].

    Science.gov (United States)

    Kitamura, Takayuki; Hoshimoto, Hiroyuki; Yamada, Yoshitsugu

    2009-10-01

    The computerized anesthesia-recording systems are expensive and the introduction of the systems takes time and requires huge effort. Generally speaking, the efficacy of the computerized anesthesia-recording systems on the anesthetic managements is focused on the ability to automatically input data from the monitors to the anesthetic records, and tends to be underestimated. However, once the computerized anesthesia-recording systems are integrated into the medical information network, several features, which definitely contribute to improve the quality of the anesthetic management, can be developed; for example, to prevent misidentification of patients, to prevent mistakes related to blood transfusion, and to protect patients' personal information. Here we describe our experiences of the introduction of the computerized anesthesia-recording systems and the construction of the comprehensive medical information network for patients undergoing surgery in The University of Tokyo Hospital. We also discuss possible efficacy of the comprehensive medical information network for patients during surgery under anesthetic managements.

  4. 1-GWh diurnal load-leveling Superconducting Magnetic Energy Storage system reference design

    International Nuclear Information System (INIS)

    Rogers, J.D.; Hassenzahl, W.V.; Schermer, R.I.

    1979-09-01

    A point reference design has been completed for a 1-GWh Superconducting Magnetic Energy Storage system. The system is for electric utility diurnal load-leveling but can also function to meet much faster power demands including dynamic stabilization. This study explores several concepts of design not previously considered in the same detail as treated here. Because the study is for a point design, optimization in all respects is not complete. This report examines aspects of the coil, the superconductor supported off of the dewar shell, the dewar shell, and its configuration and stresses, the underground excavation and construction for holding the superconducting coil and its dewar, the helium refrigeration system, the electrical converter system, the vacuum system, the guard coil, and the costs. This report is divided into two major portions. The first is a general treatment of the work and the second is seven detailed technical appendices issued as separate reports. The information presented on the aluminum stabilizer for the conductor, on the excavation, and on the converter is based upon industrial studies contracted for this work

  5. High-density fluid-perturbation theory based on an inverse 12th-power hard-sphere reference system

    International Nuclear Information System (INIS)

    Ross, M.

    1979-01-01

    A variational theory is developed that is accurate at normal liquid densities and densities up to 4 times that of the argon triple point. This theory uses the inverse 12th-power potential as a reference system. The properties of this reference system are expressed in terms of hard-sphere packing fractions by using a modified form of hard-space variational theory. As a result of this ''bootstrapping,'' a variational procedure may be followed that employs the inverse 12th-power system as a reference but uses the hard-sphere packing fraction as the scaling parameter with which to minimize the Helmholtz free energy

  6. Venous, Arterialized-Venous, or Capillary Glucose Reference Measurements for the Accuracy Assessment of a Continuous Glucose Monitoring System

    NARCIS (Netherlands)

    Kropff, Jort; van Steen, Sigrid C.; deGraaff, Peter; Chan, Man W.; van Amstel, Rombout B. E.; DeVries, J. Hans

    2017-01-01

    Background: Different reference methods are used for the accuracy assessment of continuous glucose monitoring (CGM) systems. The effect of using venous, arterialized-venous, or capillary reference measurements on CGM accuracy is unclear. Methods: We evaluated 21 individuals with type 1 diabetes

  7. Determining the direction of a geometrical/optical reference axis in the coordinate system of a triaxial magnetometer sensor

    DEFF Research Database (Denmark)

    Primdahl, Fritz; Brauer, Peter; Merayo, José M.G.

    2002-01-01

    optical or geometrical axes in order to be able to determine the precise orientation of the magnetic coordinate axes in an external reference system. Two methods for determining a reference axis in the sensor coordinates are discussed: (1) using a triaxial coil facility to measure the sensor orientation...

  8. Prevention of hypothermia in patients undergoing orthotopic liver transplantation using the humigard® open surgery humidification system: a prospective randomized pilot and feasibility clinical trial.

    Science.gov (United States)

    Weinberg, Laurence; Huang, Andrew; Alban, Daniel; Jones, Robert; Story, David; McNicol, Larry; Pearce, Brett

    2017-01-23

    Perioperative thermal disturbances during orthotopic liver transplantation (OLT) are common. We hypothesized that in patients undergoing OLT the use of a humidified high flow CO 2 warming system maintains higher intraoperative temperatures when compared to standardized multimodal strategies to maintain thermoregulatory homeostasis. We performed a randomized pilot study in adult patients undergoing primary OLT. Participants were randomized to receive either open wound humidification with a high flow CO 2 warming system in addition to standard care (Humidification group) or to standard care alone (Control group). The primary end point was nasopharyngeal core temperature measured 5 min immediately prior to reperfusion of the donor liver (Stage 3 - 5 min). Secondary endpoints included intraoperative PaCO 2 , minute ventilation and the use of vasoconstrictors. Eleven patients were randomized to each group. Both groups were similar for age, body mass index, MELD, SOFA and APACHE II scores, baseline temperature, and duration of surgery. Immediately prior to reperfusion (Stage 3 - 5 min) the mean (SD) core temperature was higher in the Humidification Group compared to the Control Group: 36.0 °C (0.13) vs. 35.4 °C (0.22), p = 0.028. Repeated measured ANOVA showed that core temperatures over time during the stages of the transplant were higher in the Humidification Group compared to the Control Group (p < 0.0001). There were no significant differences in the ETCO 2 , PaCO 2 , minute ventilation, or inotropic support. The humidified high flow CO 2 warming system was superior to standardized multimodal strategies in maintaining normothermia in patients undergoing OLT. Use of the device was feasible and did not interfere with any aspects of surgery. A larger study is needed to investigate if the improved thermoregulation observed is associated with improved patient outcomes. ACTRN12616001631493 . Retrospectively registered 25 November 2016.

  9. A system for environmental protection. Reference dose models for fauna and flora

    International Nuclear Information System (INIS)

    Pentreath, R.J.; Woodhead, D.S.

    2000-01-01

    Ideas have already been published on how the current problems relating to environmental protection could be explicitly addressed. One of the basic cornerstones of the proposed system is that of the use of reference dose models for fauna and flora, in a manner analogous to those used for the human species. The concept is that, for a number of both aquatic and terrestrial fauna and flora types, 'reference' dose models, and dose per unit (internal and external) exposure tables, could be compiled. These would then be used to draw broad conclusions on the likely effects for such organisms in relation to three broad environment end points of concern: life shortening; impairment of reproductive capacity; and scorable, cytogenetic damage. The level of complexity of the dose models needs to be commensurate with the morphological complexity of the modelled organism, its size, and the data bases which are either available or could be reasonably obtained. The most basic models considered are either solid ellipsoids or spheres, with fixed dimensions. Secondary models contain internal, but relatively simple geometric features representative of those key organs or tissues for which more precise estimates of dose are required. Their level of complexity is also a function of different internal and external sources of radiation, and expected differences in radiosensitivities. Tertiary models -of greater complexity- are only considered to be of value for higher vertebrates. The potential derivation and use of all three sets of models is briefly discussed. (author)

  10. Distributed Consensus Tracking for Second-Order Nonlinear Multiagent Systems with a Specified Reference State

    Directory of Open Access Journals (Sweden)

    Guoguang Wen

    2014-01-01

    Full Text Available This paper mainly addresses the distributed consensus tracking problem for second-order nonlinear multiagent systems with a specified reference trajectory. The dynamics of each follower consists of two terms: nonlinear inherent dynamics and a simple communication protocol relying only on the position and velocity information of its neighbors. The consensus reference is taken as a virtual leader, whose output is only its position and velocity information that is available to only a subset of a group of followers. To achieve consensus tracking, a class of nonsmooth control protocols is proposed which reply on the relative information among the neighboring agents. Then some corresponding sufficient conditions are derived. It is shown that if the communication graph associated with the virtual leader and followers is connected at each time instant, the consensus can be achieved at least globally exponentially with the proposed protocol. Rigorous proofs are given by using graph theory, matrix theory, and Lyapunov theory. Finally, numerical examples are presented to illustrate the theoretical analysis.

  11. Oncogenetics service and the Brazilian public health system: the experience of a reference Cancer Hospital.

    Science.gov (United States)

    Palmero, Edenir I; Galvão, Henrique C R; Fernandes, Gabriela C; Paula, André E de; Oliveira, Junea C; Souza, Cristiano P; Andrade, Carlos E; Romagnolo, Luis G C; Volc, Sahlua; C Neto, Maximiliano; Sabato, Cristina; Grasel, Rebeca; Mauad, Edmundo; Reis, Rui M; Michelli, Rodrigo A D

    2016-05-13

    The identification of families at-risk for hereditary cancer is extremely important due to the prevention potential in those families. However, the number of Brazilian genetic services providing oncogenetic care is extremely low for the continental dimension of the country and its population. Therefore, at-risk patients do not receive appropriate assistance. This report describes the creation, structure and management of a cancer genetics service in a reference center for cancer prevention and treatment, the Barretos Cancer Hospital (BCH). The Oncogenetics Department (OD) of BCH offers, free of charge, to all patients/relatives with clinical criteria, the possibility to perform i) genetic counseling, ii) preventive examinations and iii) genetic testing with the best quality standards. The OD has a multidisciplinary team and is integrated with all specialties. The genetic counseling process consists (mostly) of two visits. In 2014, 614 individuals (371 families) were seen by the OD. To date, over 800 families were referred by the OD for genetic testing. The support provided by the Oncogenetics team is crucial to identify at-risk individuals and to develop preventive and personalized behaviors for each situation, not only to the upper-middle class population, but also to the people whose only possibility is the public health system.

  12. The derivation of the general form of kinematics with the universal reference system

    Directory of Open Access Journals (Sweden)

    Karol Szostek

    2018-03-01

    Full Text Available In the article, the whole class of time and position transformations was derived. These transformations were derived based on the analysis of the Michelson-Morley experiment and its improved version, that is the Kennedy-Thorndike experiment. It is possible to derive a different kinematics of bodies based on each of these transformations. In this way, we demonstrated that the Special Theory of Relativity is not the only theory explaining the results of experiments with light. There is the whole continuum of the theories of kinematics of bodies which correctly explain the Michelson-Morley experiment and other experiments in which the velocity of light is measured. Based on the derived transformations, we derive the general formula for the velocity of light in vacuum measured in any inertial reference system. We explain why the Michelson-Morley and Kennedy-Thorndike experiments could not detect the ether. We present and discuss three examples of specific transformations. Finally, we explain the phenomenon of anisotropy of the cosmic microwave background radiation by means of the presented theory. The theory derived in this work is called the Special Theory of Ether – with any transverse contraction. The entire article contains only original research conducted by its authors. Keywords: Kinematics of bodies, Universal frame of reference, Transformation of time and position, One-way speed of light, Anisotropy of cosmic microwave background

  13. The economic value of one ton CO2: what system of reference for public action?

    International Nuclear Information System (INIS)

    2007-04-01

    Given the convergence of scientific analyses of global warming and its consequences for the planet - evaluated for years by the Intergovernmental Panel on Climate Change (IPCC) - it is no longer possible to postpone the efforts required to reduce our emissions of greenhouse gases substantially. However, the choice of actions to take and the calendar of priorities are proving complex to define: the social and economic consequences are great, and neither France (which represents 2% of global emissions) nor Europe (15%) are up to treating the problem independently of the rest of the world. Faced with this challenge, and with budgetary constraints imposing a rationalisation of expenditure, public action must have measuring instruments at its disposal: the value of one ton of carbon is one such instrument. This Strategic Newswatch has a twofold objective: to recall the usefulness of this reference value which, though it cannot guarantee the validity of different public policies, may contribute to ensuring their consistency; and to present the different approaches and difficulties that producing such a reference system introduces. (author)

  14. A Practical Method for Implementing an Attitude and Heading Reference System

    Directory of Open Access Journals (Sweden)

    Rodrigo Munguía

    2014-04-01

    Full Text Available This paper describes a practical and reliable algorithm for implementing an Attitude and Heading Reference System (AHRS. This kind of system is essential for real time vehicle navigation, guidance and control applications. When low cost sensors are used, efficient and robust algorithms are required for performance to be acceptable. The proposed method is based on an Extended Kalman Filter (EKF in a direct configuration. In this case, the filter is explicitly derived from both the kinematic and error models. The selection of this kind of EKF configuration can help in ensuring a tight integration of the method for its use in filter-based localization and mapping systems in autonomous vehicles. Experiments with real data show that the proposed method is able to maintain an accurate and drift-free attitude and heading estimation. An additional result is to show that there is no ostensible reason for preferring that the filter have an indirect configuration over a direct configuration for implementing an AHRS system.

  15. Swiss hydropower in competition - an analysis with reference to the future European power supply system

    International Nuclear Information System (INIS)

    Balmer, M.; Spreng, D.; Moest, D.

    2006-01-01

    This article takes a look at a number of questions in relation to the future use of Swiss hydropower that are neither clear nor unchallenged. Questions concerning the replacement or refurbishment of hydropower schemes that will have to be renewed in the next few years are asked. Also, developments in the European power market are looked at. The future influence of wind power, trading with CO 2 certificates, increases in the price of gas etc. are examined. An analysis of the competitiveness of Swiss hydropower with reference to the European power supply system that was made by the Centre for Energy Policy and Economics CEPE at the Swiss Federal Institute of Technology ETH is described. The 'Perseus'-model developed by CEPE and the Industrial Technology Institute at the University of Karlsruhe in Germany is used to analyse possible developments over the period up to 2030. The results are presented in graphical form and commented on

  16. Patients' knowledge and attitude towards therapeutic reference pricing system in Slovenia.

    Science.gov (United States)

    Marđetko, Nika; Kos, Mitja

    2016-10-01

    Background The therapeutic reference pricing (TRP) in Slovenia was implemented for proton pump inhibitors in 2013 and for angiotensin-converting enzyme inhibitors and lipid-lowering medicines in 2014. Objective The study aimed to assess patients' knowledge and attitude towards the TRP system. Moreover, the patients' willingness to pay was evaluated for patients who rejected the substitution of a current medicine within a therapeutic class by the reference medicine for which no co-payment is needed. Setting Invitation of patients to participate in a survey and filling in the first part of the questionnaire was run in the community pharmacies in Slovenia. The second part of the questionnaire was filled in at patients' home. Method A representative sample of 676 patients that had been prescribed at least one medicine from the three therapeutic classes was surveyed. The survey was carried out from 15th May to 15th June 2014 in 40 community pharmacies with the help of the pharmacists, who filled in the first part of the questionnaire in the presence of the patients. The second part of the questionnaire was filled in by 475 patients at home and returned by prepaid mail. Main outcome measure Patients' knowledge of and attitude to the TRP system implemented into Slovenian health care practice. Results Most of the statements describing patient' rights and duties within the TRP system were known by approximately 50 % of the patients. Patients were inhomogeneous in their view about the necessity and benefits of the TRP system, most of them regarded it as an unnecessary burden. Among 50.4 % of the patients who were required to copay for their medicine, 46.7 % accepted and 3.7 % rejected co-payment. The average co-payment was € 6.92, while the expressed average willingness to co-pay was € 10.4 per 3 months of therapy. Conclusion Our results indicate that the implementation of the TRP system and potential upgrades represent a significant challenge for the patients.

  17. AMBI indices and multivariate approach to assess the ecological health of Vellar-Coleroon estuarine system undergoing various human activities.

    Science.gov (United States)

    Sigamani, Sivaraj; Perumal, Murugesan; Arumugam, Silambarasan; Preetha Mini Jose, H M; Veeraiyan, Bharathidasan

    2015-11-15

    Estuaries receive a considerable amount of pollutants from various sources. Presently an attempt has been made to assess whether the aquaculture discharges and dredging activities alter the ecological conditions of Vellar-Coleroon estuarine complex. The European Water Framework Directive (WFD) established a framework for the protection of marine waters. In this commission, a variety of indices were used, among them, AMBI (AZTI Marine Biotic Index) indices along with multivariate statistical approach is unique, to assess the ecological status by using macrobenthic communities. Keeping this in view, stations VE-1 and VE-4 in Vellar; CE-6 and CE-7 in Coleroon estuaries showed moderately disturbed with the AMBI values ranging between 3.45 and 3.72. The above said stations were situated near the shrimp farm discharge point and sites of dredging activities. The present study proves that various statistical and biotic indices have great potential in assessing the nature of the ecosystem undergoing various human pressures. Copyright © 2015 Elsevier Ltd. All rights reserved.

  18. Examining egocentric and allocentric frames of reference in virtual space systems

    NARCIS (Netherlands)

    Friedman, A.

    2005-01-01

    The aim of this paper is to examine the egocentric and allocentric frames of reference, through evidence from both gesture and linguistic communication. The action of frames of reference, helps the user refer to the agent as a base for movement or to the object as a guiding point. We will show that

  19. Effect of the waste exclusion distance on the postclosure performance of a reference disposal system

    International Nuclear Information System (INIS)

    Goodwin, B.W.; Hajas, W.C.; Melnyk, T.W.; Kitson, C.I.

    1995-07-01

    The concept for disposal of Canada's nuclear fuel waste involves the isolation of the waste in corrosion-resistant containers placed in a sealed vault at a depth of 500 to 1000 metres in plutonic rock of the Canadian Shield. The technical feasibility of this concept, and its impact on the environment and human health, are summarized in an Environmental Impact Statement (EIS). The EIS is supported by nine primary references, one of which describes the postclosure assessment of the concept. The postclosure assessment is concerned with the long-term performance and behaviour of the disposal system, starting from the time the disposal facility is closed and extending far into the future. The discussions presented in the EIS and the postclosure assessment are based on a case study of a hypothetical disposal system with specific design features and host rock characteristics. The design features are founded on a conceptual engineering study and the rock characteristics are derived from geological studies of a field research area. In the case study, the long-term performance of the hypothetical disposal system was strongly dependent on a design parameter called the waste exclusion distance. This distance is defined as the minimum length of low-permeability sparsely fractured rock between the waste-emplacement part of the hypothetical vault and a nearby conductive fracture zone in the host rock. In this report, we examine trends in estimates of radiological impact as a function of the waste exclusion distance. (author). 18 refs., 14 figs

  20. Operators Manual and Technical Reference for the Z-Beamlet Phase Modulation Failsafe System: Version 1.

    Energy Technology Data Exchange (ETDEWEB)

    Armstrong, Darrell J.

    2014-09-01

    The need for pulse energies exceeding 4 kJ and pulse lengths [?] 2 ns in Sandia's Z-Beamlet laser (ZBL) requires that the single-frequency spectrum of its fiber-laser master oscillator be converted to a phase modulated spectrum with a modulation in dex [?] 5. Because accidental injection of single-frequency light into ZBL could result i n damage to optical materials from transverse stimulated Brillouin scattering, the presence of phase modulated (PM) light must be monitored by a reliable failsafe system that can stop a las er shot within of a few 10's of ns following a failure of the PM system. This requirement is met by combining optical heterodyne detection with high-speed electronics to indicate the pres ence or absence of phase modulated light. The transition time for the failsafe signal resultin g from a sudden failure using this technique is approximately 35 ns. This is sufficiently short to safely stop a single-frequency laser pulse from leaving ZBL's regenerative amplifier with a n approximately 35 ns margin of safety. This manual and technical reference contains detai led instructions for daily use of the PM failsafe system and provides enough additional informat ion for its maintenance and repair.

  1. Histological and reference system for the analysis of mouse intervertebral disc.

    Science.gov (United States)

    Tam, Vivian; Chan, Wilson C W; Leung, Victor Y L; Cheah, Kathryn S E; Cheung, Kenneth M C; Sakai, Daisuke; McCann, Matthew R; Bedore, Jake; Séguin, Cheryle A; Chan, Danny

    2018-01-01

    A new scoring system based on histo-morphology of mouse intervertebral disc (IVD) was established to assess changes in different mouse models of IVD degeneration and repair. IVDs from mouse strains of different ages, transgenic mice, or models of artificially induced IVD degeneration were assessed. Morphological features consistently observed in normal, and early/later stages of degeneration were categorized into a scoring system focused on nucleus pulposus (NP) and annulus fibrosus (AF) changes. "Normal NP" exhibited a highly cellularized cell mass that decreased with natural ageing and in disc degeneration. "Normal AF" consisted of distinct concentric lamellar structures, which was disrupted in severe degeneration. NP/AF clefts indicated more severe changes. Consistent scores were obtained between experienced and new users. Altogether, our scoring system effectively differentiated IVD changes in various strains of wild-type and genetically modified mice and in induced models of IVD degeneration, and is applicable from the post-natal stage to the aged mouse. This scoring tool and reference resource addresses a pressing need in the field for studying IVD changes and cross-study comparisons in mice, and facilitates a means to normalize mouse IVD assessment between different laboratories. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 36:233-243, 2018. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  2. A Software Reference Architecture for Service-Oriented 3D Geovisualization Systems

    Directory of Open Access Journals (Sweden)

    Dieter Hildebrandt

    2014-12-01

    Full Text Available Modern 3D geovisualization systems (3DGeoVSs are complex and evolving systems that are required to be adaptable and leverage distributed resources, including massive geodata. This article focuses on 3DGeoVSs built based on the principles of service-oriented architectures, standards and image-based representations (SSI to address practically relevant challenges and potentials. Such systems facilitate resource sharing and agile and efficient system construction and change in an interoperable manner, while exploiting images as efficient, decoupled and interoperable representations. The software architecture of a 3DGeoVS and its underlying visualization model have strong effects on the system’s quality attributes and support various system life cycle activities. This article contributes a software reference architecture (SRA for 3DGeoVSs based on SSI that can be used to design, describe and analyze concrete software architectures with the intended primary benefit of an increase in effectiveness and efficiency in such activities. The SRA integrates existing, proven technology and novel contributions in a unique manner. As the foundation for the SRA, we propose the generalized visualization pipeline model that generalizes and overcomes expressiveness limitations of the prevalent visualization pipeline model. To facilitate exploiting image-based representations (IReps, the SRA integrates approaches for the representation, provisioning and styling of and interaction with IReps. Five applications of the SRA provide proofs of concept for the general applicability and utility of the SRA. A qualitative evaluation indicates the overall suitability of the SRA, its applications and the general approach of building 3DGeoVSs based on SSI.

  3. The Poisson alignment reference system implementation at the Advanced Photon Source

    International Nuclear Information System (INIS)

    Feier, I.

    1998-01-01

    The Poisson spot was established using a collimated laser beam from a 3-mW diode laser. It was monitored on a quadrant detector and found to be very sensitive to vibration and air disturbances. Therefore, for future work we strongly recommend a sealed vacuum tube in which the Poisson line may be propagated. A digital single-axis feedback system was employed to generate an straight line reference (SLR) on the X axis. Pointing accuracy was better than 8 ± 2 microns at a distance of 5 m. The digital system was found to be quite slow with a maximum bandwidth of 47 ± 9 Hz. Slow drifts were easily corrected but any vibration over 5 Hz was not. We recommend an analog proportional-integral-derivative (PID) controller for high bandwidth and smooth operation of the kinematic mirror. Although the Poisson alignment system (PAS) at the Advanced Photon Source is still in its infancy, it already shows great promise as a possible alignment system for the low-energy undulator test line (LEUTL). Since components such as wigglers and quadruples will initially be aligned with respect to each other using conventional means and mounted on some kind of rigid rail, the goal would be to align six to ten such rails over a distance of about 30 m. The PAS could be used to align these rails by mounting a sphere at the joint between two rails. These spheres would need to be in a vacuum pipe to eliminate the refractive effects of air. Each sphere would not be attached to either rail but instead to a flange connecting the vacuum pipes of each rail. Thus the whole line would be made up of straight, rigid segments that could be aligned by moving the joints. Each sphere would have its own detector, allowing the operators to actively monitor the position of each joint and therefore the overall alignment of the system

  4. Investigation on Reference Frames and Time Systems in Multi-GNSS

    Directory of Open Access Journals (Sweden)

    Luca Nicolini

    2018-01-01

    Full Text Available Receivers able to track satellites belonging to different GNSSs (Global Navigation Satellite Systems are available on the market. To compute coordinates and velocities it is necessary to identify all the elements that contribute to interoperability of the different GNSSs. For example the timescales kept by different GNSSs have to be aligned. Receiver-specific biases, or firmware-dependent biases, need to be calibrated. The reference frame used in the representation of the orbits must be unique. In this paper we address the interoperability issues from the standpoint of a Single Point Positioning (SPP user, i.e., using pseudoranges and broadcast ephemeris. The biases between GNSSs timescales and receiver-dependent biases are analyzed for a set of 31 MGEX (Multi-GNSS Experiment stations over a time span of more than three years. Time series of biases between timescales of GPS (Global Positioning System, GLONASS (Global Navigation Satellite System, Galileo, BeiDou, QZSS (Quasi-Zenith Satellite System, SBAS (Satellite Based Augmentation System and NAVIC (Navigation with Indian Constellation are investigated, in addition to the identification of events like discontinuity of receiver-dependent biases due to firmware updating. The GPS broadcast reference frame is shown to be aligned to the one (IGS14 realized by the precise ephemeris of CODE (Center for Orbit Determination in Europe to within 0.1 m and 2 milliarcsec, with values dependent on whether IIR-A, IIR-B/M or IIF satellite blocks are considered. Larger offsets are observed for GLONASS, up to 1 m for GLONASS K satellites. For Galileo the alignment of the broadcast orbit to IGS14/CODE is again at the 0.1 m and several milliarcsec level, with the FOC (Full Operational Capability satellites slightly better than IOV (In Orbit Validation. For BeiDou an alignment of the broadcast frame to IGS14/CODE comparable to GLONASS is observed, regardless of whether IGSO (Inclined Geosynchronous Orbit or MEO

  5. Flurbiprofen Axetil Enhances Analgesic Effects of Sufentanil and Attenuates Postoperative Emergence Agitation and Systemic Proinflammation in Patients Undergoing Tangential Excision Surgery

    Directory of Open Access Journals (Sweden)

    Wujun Geng

    2015-01-01

    Full Text Available Objective. Our present study tested whether flurbiprofen axetil could reduce perioperative sufentanil consumption and provide postoperative analgesia with decrease in emergency agitation and systemic proinflammatory cytokines release. Methods. Ninety patients undergoing tangential excision surgery were randomly assigned to three groups: (1 preoperative dose of 100 mg flurbiprofen axetil and a postoperative dose of 2 μg/kg sufentanil and 10 mL placebo by patient-controlled analgesia (PCA pump, (2 preoperative dose of 100 mg flurbiprofen axetil and a postoperative dose of 2 μg/kg sufentanil and 100 mg flurbiprofen axetil by PCA pump, and (3 10 mL placebo and a postoperative dose of 2 μg/kg sufentanil and 10 mL placebo by PCA pump. Results. Preoperative administration of flurbiprofen axetil decreased postoperative tramadol consumption and the visual analog scale at 4, 6, 12, and 24 h after surgery, which were further decreased by postoperative administration of flurbiprofen axetil. Furthermore, flurbiprofen axetil attenuated emergency agitation score and Ramsay score at 0, 5, and 10 min after extubation and reduced the TNF-α and interleukin- (IL- 6 levels at 24 and 48 h after the operation. Conclusion. Flurbiprofen axetil enhances analgesic effects of sufentanil and attenuates emergence agitation and systemic proinflammation in patients undergoing tangential excision surgery.

  6. Flurbiprofen Axetil Enhances Analgesic Effects of Sufentanil and Attenuates Postoperative Emergence Agitation and Systemic Proinflammation in Patients Undergoing Tangential Excision Surgery.

    Science.gov (United States)

    Geng, Wujun; Hong, Wandong; Wang, Junlu; Dai, Qinxue; Mo, Yunchang; Shi, Kejian; Sun, Jiehao; Qin, Jinling; Li, Mei; Tang, Hongli

    2015-01-01

    Our present study tested whether flurbiprofen axetil could reduce perioperative sufentanil consumption and provide postoperative analgesia with decrease in emergency agitation and systemic proinflammatory cytokines release. Ninety patients undergoing tangential excision surgery were randomly assigned to three groups: (1) preoperative dose of 100 mg flurbiprofen axetil and a postoperative dose of 2 μg/kg sufentanil and 10 mL placebo by patient-controlled analgesia (PCA) pump, (2) preoperative dose of 100 mg flurbiprofen axetil and a postoperative dose of 2 μg/kg sufentanil and 100 mg flurbiprofen axetil by PCA pump, and (3) 10 mL placebo and a postoperative dose of 2 μg/kg sufentanil and 10 mL placebo by PCA pump. Preoperative administration of flurbiprofen axetil decreased postoperative tramadol consumption and the visual analog scale at 4, 6, 12, and 24 h after surgery, which were further decreased by postoperative administration of flurbiprofen axetil. Furthermore, flurbiprofen axetil attenuated emergency agitation score and Ramsay score at 0, 5, and 10 min after extubation and reduced the TNF-α and interleukin- (IL-) 6 levels at 24 and 48 h after the operation. Flurbiprofen axetil enhances analgesic effects of sufentanil and attenuates emergence agitation and systemic proinflammation in patients undergoing tangential excision surgery.

  7. Venous, Arterialized-Venous, or Capillary Glucose Reference Measurements for the Accuracy Assessment of a Continuous Glucose Monitoring System.

    Science.gov (United States)

    Kropff, Jort; van Steen, Sigrid C; deGraaff, Peter; Chan, Man W; van Amstel, Rombout B E; DeVries, J Hans

    2017-11-01

    Different reference methods are used for the accuracy assessment of continuous glucose monitoring (CGM) systems. The effect of using venous, arterialized-venous, or capillary reference measurements on CGM accuracy is unclear. We evaluated 21 individuals with type 1 diabetes using a capillary calibrated CGM system. Venous or arterialized-venous reference glucose samples were taken every 15 min at two separate visits and assessed per YSI 2300 STAT Plus. Arterialization was achieved by heated-hand technique. Capillary samples were collected hourly during the venous reference visit. The investigation sequence (venous or arterialized-venous) was randomized. Effectiveness of arterialization was measured by comparing free venous oxygen pressure (PO2) of both visit days. Primary endpoint was the median absolute relative difference (ARD). Median ARD using arterialized-venous reference samples was not different from venous samples (point estimated difference 0.52%, P = 0.181). When comparing the three reference methods, median ARD was also not different over the full glycemic range (venous 9.0% [n = 681], arterialized-venous 8.3% [n = 684], and capillary 8.1% [n = 205], P = 0.216), nor over the separate glucose ranges. Arterialization was successful (PO2 venous 5.4 kPa vs. arterialized-venous 8.9 kPa, P reference measurements did not significantly impact CGM accuracy. Venous reference seems preferable due to its ease of operation.

  8. Oscillating red giants in eclipsing binary systems: empirical reference value for asteroseismic scaling relation

    Science.gov (United States)

    Themeßl, N.; Hekker, S.; Southworth, J.; Beck, P. G.; Pavlovski, K.; Tkachenko, A.; Angelou, G. C.; Ball, W. H.; Barban, C.; Corsaro, E.; Elsworth, Y.; Handberg, R.; Kallinger, T.

    2018-05-01

    The internal structures and properties of oscillating red-giant stars can be accurately inferred through their global oscillation modes (asteroseismology). Based on 1460 days of Kepler observations we perform a thorough asteroseismic study to probe the stellar parameters and evolutionary stages of three red giants in eclipsing binary systems. We present the first detailed analysis of individual oscillation modes of the red-giant components of KIC 8410637, KIC 5640750 and KIC 9540226. We obtain estimates of their asteroseismic masses, radii, mean densities and logarithmic surface gravities by using the asteroseismic scaling relations as well as grid-based modelling. As these red giants are in double-lined eclipsing binaries, it is possible to derive their independent dynamical masses and radii from the orbital solution and compare it with the seismically inferred values. For KIC 5640750 we compute the first spectroscopic orbit based on both components of this system. We use high-resolution spectroscopic data and light curves of the three systems to determine up-to-date values of the dynamical stellar parameters. With our comprehensive set of stellar parameters we explore consistencies between binary analysis and asteroseismic methods, and test the reliability of the well-known scaling relations. For the three red giants under study, we find agreement between dynamical and asteroseismic stellar parameters in cases where the asteroseismic methods account for metallicity, temperature and mass dependence as well as surface effects. We are able to attain agreement from the scaling laws in all three systems if we use Δνref, emp = 130.8 ± 0.9 μHz instead of the usual solar reference value.

  9. Performance evaluation of the reference system for calibration of IPEN activities

    International Nuclear Information System (INIS)

    Martins, Elaine Wirney; Potiens, Maria da Penha A.

    2011-01-01

    The formation of good quality image in nuclear medicine services depends on several factors, including the radiopharmaceutical activity, which must be well determined by a specific apparatus, in perfect operating condition, called activimeter. Therefore, the establishment of a quality control program for measuring the radiopharmaceuticals radioactivity before being administered to the patient is crucial to the safe and effective use of the radiopharmaceuticals used in diagnostic and therapeutical procedures. Two activimeters, belonging by the Laboratorio de Calibracao do Instrumentos (LCI) of Instituto de Pesquisas Energeticas e Nucleares (IPEN), were evaluated: the secondary standard system NPL-CRC radionuclide calibrator, manufactured by Southern Scientific, and the work standard system CRC-15BT with traceability to National Institute of Standard and Technology (NIST). A set of standard sources of the radionuclides 1 '3 3 Ba, 57 Co and 137 Cs was used as reference to perform the quality control tests. The precision, accuracy and repeatability tests were in agreement with those established by the CNEN-NE 3.05 Brazilian standard, which recommends the variation limit of up to 10%, 5% and 5% respectively. The results obtained for the reproducibility tests presented a variation always below 1,5%, which means it is within the IEC 61674 international standard recommendation of up to 3%. Activimeters response regarding linearity showed concordance between the measured activities and the theoretical curve for both activimeters. (author)

  10. Performance evaluation of the reference system for calibration of IPEN activities

    Energy Technology Data Exchange (ETDEWEB)

    Martins, Elaine Wirney; Potiens, Maria da Penha A., E-mail: ewmartins@ipen.br, E-mail: mppalbu@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2011-07-01

    The formation of good quality image in nuclear medicine services depends on several factors, including the radiopharmaceutical activity, which must be well determined by a specific apparatus, in perfect operating condition, called activimeter. Therefore, the establishment of a quality control program for measuring the radiopharmaceuticals radioactivity before being administered to the patient is crucial to the safe and effective use of the radiopharmaceuticals used in diagnostic and therapeutical procedures. Two activimeters, belonging by the Laboratorio de Calibracao do Instrumentos (LCI) of Instituto de Pesquisas Energeticas e Nucleares (IPEN), were evaluated: the secondary standard system NPL-CRC radionuclide calibrator, manufactured by Southern Scientific, and the work standard system CRC-15BT with traceability to National Institute of Standard and Technology (NIST). A set of standard sources of the radionuclides {sup 1}'3{sup 3}Ba, {sup 57}Co and {sup 137}Cs was used as reference to perform the quality control tests. The precision, accuracy and repeatability tests were in agreement with those established by the CNEN-NE 3.05 Brazilian standard, which recommends the variation limit of up to 10%, 5% and 5% respectively. The results obtained for the reproducibility tests presented a variation always below 1,5%, which means it is within the IEC 61674 international standard recommendation of up to 3%. Activimeters response regarding linearity showed concordance between the measured activities and the theoretical curve for both activimeters. (author)

  11. Integrated Reliability and Risk Analysis System (IRRAS), Version 2.5: Reference manual

    International Nuclear Information System (INIS)

    Russell, K.D.; McKay, M.K.; Sattison, M.B.; Skinner, N.L.; Wood, S.T.; Rasmuson, D.M.

    1991-03-01

    The Integrated Reliability and Risk Analysis System (IRRAS) is a state-of-the-art, microcomputer-based probabilistic risk assessment (PRA) model development and analysis tool to address key nuclear plant safety issues. IRRAS is an integrated software tool that gives the user the ability to create and analyze fault trees and accident sequences using a microcomputer. This program provides functions that range from graphical fault tree construction to cut set generation and quantification. Version 1.0 of the IRRAS program was released in February of 1987. Since that time, many user comments and enhancements have been incorporated into the program providing a much more powerful and user-friendly system. This version has been designated IRRAS 2.5 and is the subject of this Reference Manual. Version 2.5 of IRRAS provides the same capabilities as Version 1.0 and adds a relational data base facility for managing the data, improved functionality, and improved algorithm performance. 7 refs., 348 figs

  12. The project manager's desk reference: project planning, schedulding, evaluation, control, systems

    National Research Council Canada - National Science Library

    Lewis, James P

    2007-01-01

    In this Third Edition of The Project Manager's Desk Reference, top project management consultant James Lewis arms you with today's most comprehensive and understandable project management resources...

  13. Reference and counter electrode positions affect electrochemical characterization of bioanodes in different bioelectrochemical systems

    KAUST Repository

    Zhang, Fang

    2014-06-16

    The placement of the reference electrode (RE) in various bioelectrochemical systems is often varied to accommodate different reactor configurations. While the effect of the RE placement is well understood from a strictly electrochemistry perspective, there are impacts on exoelectrogenic biofilms in engineered systems that have not been adequately addressed. Varying distances between the working electrode (WE) and the RE, or the RE and the counter electrode (CE) in microbial fuel cells (MFCs) can alter bioanode characteristics. With well-spaced anode and cathode distances in an MFC, increasing the distance between the RE and anode (WE) altered bioanode cyclic voltammograms (CVs) due to the uncompensated ohmic drop. Electrochemical impedance spectra (EIS) also changed with RE distances, resulting in a calculated increase in anode resistance that varied between 17 and 31Ω (-0.2V). While WE potentials could be corrected with ohmic drop compensation during the CV tests, they could not be automatically corrected by the potentiostat in the EIS tests. The electrochemical characteristics of bioanodes were altered by their acclimation to different anode potentials that resulted from varying the distance between the RE and the CE (cathode). These differences were true changes in biofilm characteristics because the CVs were electrochemically independent of conditions resulting from changing CE to RE distances. Placing the RE outside of the current path enabled accurate bioanode characterization using CVs and EIS due to negligible ohmic resistances (0.4Ω). It is therefore concluded for bioelectrochemical systems that when possible, the RE should be placed outside the current path and near the WE, as this will result in more accurate representation of bioanode characteristics. © 2014 Wiley Periodicals, Inc.

  14. [Evaluation of selected parameters of blood coagulation and fibrinolysis system in patients undergoing total hip replacement surgery with normovolemic hemodilution procedure and standard enoxaparine prophylaxis].

    Science.gov (United States)

    Piecuch, Wiesław; Sokołowska, Bozena; Dmoszyńska, Anna; Furmanik, Franciszek

    2003-01-01

    The aim of the study was to evaluate selected blood coagulation and fibrinolysis parameters in patients undergoing total hip replacement surgery with normovolemic hemodilution and standard enoksaparine profilaxis. The study included 66 patients undergoing hip replacement surgery. The group consisted of 51 women and 15 men, within the age range of 47-78, the mean age was 64. In 32 (subgroup II) patients the surgery was performed with the use of normovolemic hemodilution, in 34 (subgroup I) the hemodilution procedure was not applied. The enoksaparine as prophylaxis started 12 hours prior to surgery and continued during hospitalisation. The examination of the coagulation system was performed: on the day of the operation in the morning, on the day of the operation in the evening and on the first day after operation. We determined the concentrations of TAT and PAP complexes, prothrombin fragments 1 + 2 (F1 + 2) and d-dimers (DD). 1) during total hip replacement surgery and particularly in the period of the first 12 hours after the procedure marked activation of coagulation and fibrinolysis occurRed; 2) the application of the hemodilution procedure does not influence significantly the degree of coagulation and fibrinolysis disorders in the perioperative period, but could reduced incidence of thromboembolic complications in the postoperative period.

  15. Rate of alignment and communication using quantum systems in the absence of a shared frame of reference

    Science.gov (United States)

    Skotiniotis, Michael

    Quantum information theory is concerned with the storage, transmission, and manipulation of information that is represented in the degrees of freedom of quantum systems. These degrees of freedom are described relative to an external frame of reference. The lack of a requisite frame of reference imposes restrictions on the types of states quantum systems can be prepared in and the type of operations that can be performed on quantum systems. This thesis is concerned with the communication between two parties that lack a shared frame of reference. Specifically, I introduce a protocol whereby the parties can align their respective frames of reference, and a protocol for communicating quantum information in a reference frame independent manner. Using the accessible information to quantify the success of a reference frame alignment protocol I propose a new measure—the alignment rate—for quantifying the ability of a quantum state to stand in place of a classical frame of reference. I show that for the case where Alice and Bob lack a shared frame of reference associated with the groups G = U(1) and G = ZM (the finite cyclic group of M elements), the alignment rate is equal to the regularized, linearized G-asymmetry. The latter is a unique measure of the frameness of a quantum state and my result provides an operational interpretation of the G-asymmetry that was thus far lacking. In addition, I show that the alignment rate for finite cyclic groups of more than three elements is super-additive under the tensor product of two distinct pure quantum states. The latter is, to my knowledge, the first instance of a regularized quantity that exhibits super-additivity. In addition, I propose a reference-frame-independent protocol for communicating quantum information in the absence of a shared frame of reference associated with a general finite group G. The protocol transmits m logical qudits using r + m physical qudits prepared in a specific state that is reference

  16. Compilation of references, data sources and analysis methods for LMFBR primary piping system components

    International Nuclear Information System (INIS)

    Reich, M.; Esztergar, E.P.; Ellison, E.G.; Erdogan, F.; Gray, T.G.F.; Wells, C.W.

    1977-03-01

    A survey and review program for application of fracture mechanics methods in elevated temperature design and safety analysis has been initiated in December of 1976. This is the first of a series of reports, the aim of which is to provide a critical review of the theories of fracture and the application of fracture mechanics methods to life prediction, reliability and safety analysis of piping components in nuclear plants undergoing sub-creep and elevated temperature service conditions

  17. Robust stator resistance identification of an IM drive using model reference adaptive system

    International Nuclear Information System (INIS)

    Madadi Kojabadi, Hossein; Abarzadeh, Mostafa; Aghaei Farouji, Said

    2013-01-01

    Highlights: ► We estimate the stator resistance and rotor speed of the IM. ► We proposed a new quantity to estimate the speed and stator resistance of IM. ► The proposed algorithm is robust to rotor resistance variations. ► We estimate the IM speed and stator resistance simultaneously to avoid speed error. - Abstract: Model reference adaptive system (MRAS) based robust stator resistance estimator for sensorless induction motor (IM) drive is proposed. The MRAS is formed with a semi-active power quantity. The proposed identification method can be achieved with on-line tuning of the stator resistance with robustness against rotor resistance variations. Stable and efficient estimation of IM speed at low region will be guaranteed by simultaneous identification of IM speed and stator resistance. The stability of proposed stator resistance estimator is checked through Popov’s hyperstability theorem. Simulation and experimental results are given to highlight the feasibility, the simplicity, and the robustness of the proposed method.

  18. Robust Floor Determination Algorithm for Indoor Wireless Localization Systems under Reference Node Failure

    Directory of Open Access Journals (Sweden)

    Kriangkrai Maneerat

    2016-01-01

    Full Text Available One of the challenging problems for indoor wireless multifloor positioning systems is the presence of reference node (RN failures, which cause the values of received signal strength (RSS to be missed during the online positioning phase of the location fingerprinting technique. This leads to performance degradation in terms of floor accuracy, which in turn affects other localization procedures. This paper presents a robust floor determination algorithm called Robust Mean of Sum-RSS (RMoS, which can accurately determine the floor on which mobile objects are located and can work under either the fault-free scenario or the RN-failure scenarios. The proposed fault tolerance floor algorithm is based on the mean of the summation of the strongest RSSs obtained from the IEEE 802.15.4 Wireless Sensor Networks (WSNs during the online phase. The performance of the proposed algorithm is compared with those of different floor determination algorithms in literature. The experimental results show that the proposed robust floor determination algorithm outperformed the other floor algorithms and can achieve the highest percentage of floor determination accuracy in all scenarios tested. Specifically, the proposed algorithm can achieve greater than 95% correct floor determination under the scenario in which 40% of RNs failed.

  19. Improvements of MCOR: A Monte Carlo depletion code system for fuel assembly reference calculations

    Energy Technology Data Exchange (ETDEWEB)

    Tippayakul, C.; Ivanov, K. [Pennsylvania State Univ., Univ. Park (United States); Misu, S. [AREVA NP GmbH, An AREVA and SIEMENS Company, Erlangen (Germany)

    2006-07-01

    This paper presents the improvements of MCOR, a Monte Carlo depletion code system for fuel assembly reference calculations. The improvements of MCOR were initiated by the cooperation between the Penn State Univ. and AREVA NP to enhance the original Penn State Univ. MCOR version in order to be used as a new Monte Carlo depletion analysis tool. Essentially, a new depletion module using KORIGEN is utilized to replace the existing ORIGEN-S depletion module in MCOR. Furthermore, the online burnup cross section generation by the Monte Carlo calculation is implemented in the improved version instead of using the burnup cross section library pre-generated by a transport code. Other code features have also been added to make the new MCOR version easier to use. This paper, in addition, presents the result comparisons of the original and the improved MCOR versions against CASMO-4 and OCTOPUS. It was observed in the comparisons that there were quite significant improvements of the results in terms of k{sub inf}, fission rate distributions and isotopic contents. (authors)

  20. The derivation of the general form of kinematics with the universal reference system

    Science.gov (United States)

    Szostek, Karol; Szostek, Roman

    2018-03-01

    In the article, the whole class of time and position transformations was derived. These transformations were derived based on the analysis of the Michelson-Morley experiment and its improved version, that is the Kennedy-Thorndike experiment. It is possible to derive a different kinematics of bodies based on each of these transformations. In this way, we demonstrated that the Special Theory of Relativity is not the only theory explaining the results of experiments with light. There is the whole continuum of the theories of kinematics of bodies which correctly explain the Michelson-Morley experiment and other experiments in which the velocity of light is measured. Based on the derived transformations, we derive the general formula for the velocity of light in vacuum measured in any inertial reference system. We explain why the Michelson-Morley and Kennedy-Thorndike experiments could not detect the ether. We present and discuss three examples of specific transformations. Finally, we explain the phenomenon of anisotropy of the cosmic microwave background radiation by means of the presented theory. The theory derived in this work is called the Special Theory of Ether - with any transverse contraction. The entire article contains only original research conducted by its authors.

  1. Global Area Reference System (GARS), 30-minute Blocks for Louisiana, WGS84, NGA (2007) [gars_la_30min_nga_2007

    Data.gov (United States)

    Louisiana Geographic Information Center — Global Area Reference System (GARS) is developed by the National Geospatial-Intelligence Agency (NGA) as an area reference system. GARS is based on lines of...

  2. IMOS National Reference Stations: A Continental-Wide Physical, Chemical and Biological Coastal Observing System

    Science.gov (United States)

    Lynch, Tim P.; Morello, Elisabetta B.; Evans, Karen; Richardson, Anthony J.; Rochester, Wayne; Steinberg, Craig R.; Roughan, Moninya; Thompson, Peter; Middleton, John F.; Feng, Ming; Sherrington, Robert; Brando, Vittorio; Tilbrook, Bronte; Ridgway, Ken; Allen, Simon; Doherty, Peter; Hill, Katherine; Moltmann, Tim C.

    2014-01-01

    Sustained observations allow for the tracking of change in oceanography and ecosystems, however, these are rare, particularly for the Southern Hemisphere. To address this in part, the Australian Integrated Marine Observing System (IMOS) implemented a network of nine National Reference Stations (NRS). The network builds on one long-term location, where monthly water sampling has been sustained since the 1940s and two others that commenced in the 1950s. In-situ continuously moored sensors and an enhanced monthly water sampling regime now collect more than 50 data streams. Building on sampling for temperature, salinity and nutrients, the network now observes dissolved oxygen, carbon, turbidity, currents, chlorophyll a and both phytoplankton and zooplankton. Additional parameters for studies of ocean acidification and bio-optics are collected at a sub-set of sites and all data is made freely and publically available. Our preliminary results demonstrate increased utility to observe extreme events, such as marine heat waves and coastal flooding; rare events, such as plankton blooms; and have, for the first time, allowed for consistent continental scale sampling and analysis of coastal zooplankton and phytoplankton communities. Independent water sampling allows for cross validation of the deployed sensors for quality control of data that now continuously tracks daily, seasonal and annual variation. The NRS will provide multi-decadal time series, against which more spatially replicated short-term studies can be referenced, models and remote sensing products validated, and improvements made to our understanding of how large-scale, long-term change and variability in the global ocean are affecting Australia's coastal seas and ecosystems. The NRS network provides an example of how a continental scaled observing systems can be developed to collect observations that integrate across physics, chemistry and biology. PMID:25517905

  3. IMOS National Reference Stations: a continental-wide physical, chemical and biological coastal observing system.

    Directory of Open Access Journals (Sweden)

    Tim P Lynch

    Full Text Available Sustained observations allow for the tracking of change in oceanography and ecosystems, however, these are rare, particularly for the Southern Hemisphere. To address this in part, the Australian Integrated Marine Observing System (IMOS implemented a network of nine National Reference Stations (NRS. The network builds on one long-term location, where monthly water sampling has been sustained since the 1940s and two others that commenced in the 1950s. In-situ continuously moored sensors and an enhanced monthly water sampling regime now collect more than 50 data streams. Building on sampling for temperature, salinity and nutrients, the network now observes dissolved oxygen, carbon, turbidity, currents, chlorophyll a and both phytoplankton and zooplankton. Additional parameters for studies of ocean acidification and bio-optics are collected at a sub-set of sites and all data is made freely and publically available. Our preliminary results demonstrate increased utility to observe extreme events, such as marine heat waves and coastal flooding; rare events, such as plankton blooms; and have, for the first time, allowed for consistent continental scale sampling and analysis of coastal zooplankton and phytoplankton communities. Independent water sampling allows for cross validation of the deployed sensors for quality control of data that now continuously tracks daily, seasonal and annual variation. The NRS will provide multi-decadal time series, against which more spatially replicated short-term studies can be referenced, models and remote sensing products validated, and improvements made to our understanding of how large-scale, long-term change and variability in the global ocean are affecting Australia's coastal seas and ecosystems. The NRS network provides an example of how a continental scaled observing systems can be developed to collect observations that integrate across physics, chemistry and biology.

  4. Prediction of shape diameter undergoing coil embolization of saccular intracranial aneurysm treatment using a hybrid decision support system

    International Nuclear Information System (INIS)

    Owasirikul, Wiwat; Tantivatana, Jaturon; Gansawat, Duangrat; Auethavekiat, Supatana

    2013-01-01

    The purpose of the study was to design a hybrid decision support system (HDSS) that could simulate the embolized coil selection pattern of the radiologists in aneurysms treatment. As the longest available length of the coils should be used in most cases, therefore only the shape diameter (SD) selection was modeled and varied. Ninety-eight aneurysms successfully treated by a radiologist with coil embolization were divided into two groups (86 for training and 12 randomly selected for validating). Eight aneurysms treated by another radiologist were also used to cross validate the proposed HDSS. The HDSS was developed using the classification and the linear regression methods (LRM). The dome and the width of an aneurysm were used as the system inputs. The system outputs were the SDs of the first three coils indexed according to the insertion order. The HDSS that consisted of Bagging classification and LRM achieved the highest accuracy for all cases. The errors were within 1 mm for the SD selection of the first two coils. For the third coil, the SD selection within 1 mm bound had 80 % accuracy. The experimental results indicated the feasibility of using the HDSS as the guidance for selecting the SDs of the first two coils. The selection of the third coil required more training data for the rarely used SD. Moreover, the cross validation with another radiologist showed the feasibility of using the proposed HDSS as the guidance, however further validation with more data is recommended.

  5. Application Research of Horn Array Multi-Beam Antenna in Reference Source System for Satellite Interference Location

    Science.gov (United States)

    Zhou, Ping; Lin, Hui; Zhang, Qi

    2018-01-01

    The reference source system is a key factor to ensure the successful location of the satellite interference source. Currently, the traditional system used a mechanical rotating antenna which leaded to the disadvantages of slow rotation and high failure-rate, which seriously restricted the system’s positioning-timeliness and became its obvious weaknesses. In this paper, a multi-beam antenna scheme based on the horn array was proposed as a reference source for the satellite interference location, which was used as an alternative to the traditional reference source antenna. The new scheme has designed a small circularly polarized horn antenna as an element and proposed a multi-beamforming algorithm based on planar array. Moreover, the simulation analysis of horn antenna pattern, multi-beam forming algorithm and simulated satellite link cross-ambiguity calculation have been carried out respectively. Finally, cross-ambiguity calculation of the traditional reference source system has also been tested. The comparison between the results of computer simulation and the actual test results shows that the scheme is scientific and feasible, obviously superior to the traditional reference source system.

  6. High-resolution simulations of unstable cylindrical gravity currents undergoing wandering and splitting motions in a rotating system

    Science.gov (United States)

    Dai, Albert; Wu, Ching-Sen

    2018-02-01

    High-resolution simulations of unstable cylindrical gravity currents when wandering and splitting motions occur in a rotating system are reported. In this study, our attention is focused on the situation of unstable rotating cylindrical gravity currents when the ratio of Coriolis to inertia forces is larger, namely, 0.5 ≤ C ≤ 2.0, in comparison to the stable ones when C ≤ 0.3 as investigated previously by the authors. The simulations reproduce the major features of the unstable rotating cylindrical gravity currents observed in the laboratory, i.e., vortex-wandering or vortex-splitting following the contraction-relaxation motion, and good agreement is found when compared with the experimental results on the outrush radius of the advancing front and on the number of bulges. Furthermore, the simulations provide energy budget information which could not be attained in the laboratory. After the heavy fluid is released, the heavy fluid collapses and a contraction-relaxation motion is at work for approximately 2-3 revolutions of the system. During the contraction-relaxation motion of the heavy fluid, the unstable rotating cylindrical gravity currents behave similar to the stable ones. Towards the end of the contraction-relaxation motion, the dissipation rate in the system reaches a local minimum and a quasi-geostrophic equilibrium state is reached. After the quasi-geostrophic equilibrium state, vortex-wandering or vortex-splitting may occur depending on the ratio of Coriolis to inertia forces. The vortex-splitting process begins with non-axisymmetric bulges and, as the bulges grow, the kinetic energy increases at the expense of decreasing potential energy in the system. The completion of vortex-splitting is accompanied by a local maximum of dissipation rate and a local maximum of kinetic energy in the system. A striking feature of the unstable rotating cylindrical gravity currents is the persistent upwelling and downwelling motions, which are observed for both the

  7. Long-term pavement performance ancillary information management system (AIMS) reference guide.

    Science.gov (United States)

    2012-11-01

    This document provides information on the Long-Term Pavement Performance (LTPP) program ancillary information. : Ancillary information includes data, images, reference materials, resource documents, and other information that : support and extend the...

  8. Assessment of Effectiveness of Geologic Isolation Systems: REFERENCE SITE INITIAL ASSESSMENT FOR A SALT DOME REPOSITORY

    Energy Technology Data Exchange (ETDEWEB)

    Harwell, M. A.; Brandstetter, A.; Benson, G. L.; Raymond, J. R.; Brandley, D. J.; Serne, R. J.; Soldat, J. K.; Cole, C. R.; Deutsch, W. J.; Gupta, S. K.; Harwell, C. C.; Napier, B. A.; Reisenauer, A. E.; Prater, L. S.; Simmons, C. S.; Strenge, D. L.; Washburn, J. F.; Zellmer, J. T.

    1982-06-01

    As a methodology demonstration for the Office of Nuclear Waste Isolation (ONWI), the Assessment of Effectiveness of Geologic Isolation Systems (AEGIS) Program conducted an initial reference site analysis of the long-term effectiveness of a salt dome repository. The Hainesville Salt Dome in Texas was chosen to be representative of the Gulf Coast interior salt domes; however, the Hainesville Site has been eliminated as a possible nuclear waste repository site. The data used for this exercise are not adequate for an actual assessment, nor have all the parametric analyses been made that would adequately characterize the response of the geosystem surrounding the repository. Additionally, because this was the first exercise of the complete AEGIS and WASTE Rock Interaction Technology (WRIT) methodology, this report provides the initial opportunity for the methodology, specifically applied to a site, to be reviewed by the community outside the AEGIS. The scenario evaluation, as a part of the methodology demonstration, involved consideration of a large variety of potentially disruptive phenomena, which alone or in concert could lead to a breach in a salt dome repository and to a subsequent transport of the radionuclides to the environment. Without waste- and repository-induced effects, no plausible natural geologic events or processes which would compromise the repository integrity could be envisioned over the one-million-year time frame after closure. Near-field (waste- and repository-induced) effects were excluded from consideration in this analysis, but they can be added in future analyses when that methodology development is more complete. The potential for consequential human intrusion into salt domes within a million-year time frame led to the consideration of a solution mining intrusion scenario. The AEGIS staff developed a specific human intrusion scenario at 100 years and 1000 years post-closure, which is one of a whole suite of possible scenarios. This scenario

  9. Specifications for trueness and precision of a reference measurement system for serum/plasma 25-hydroxyvitamin D analysis.

    Science.gov (United States)

    Stöckl, Dietmar; Sluss, Patrick M; Thienpont, Linda M

    2009-10-01

    The divergence in analytical quality of serum/plasma 25-hydroxy-vitamin D analysis calls for defining specifications for a reference measurement system. Fundamentally, in a reference measurement system, there should be a relationship between the analytical specifications for higher- (reference) and lower-order (routine) measurements. Therefore, when setting specifications, we started with limits for routine imprecision (CV(rou)) and bias (B(rou)) using 4 models: (1) the misclassifications in diagnosis, (2) biological variation data (reference interval (RI) and monitoring), (3) expert recommendations, and (4) state-of-the-art performance. Then, we used the derived goals to tailor those for reference measurements and certified reference materials (CRMs) for calibration by setting the limits for CV(ref) at 0.5 CV(rou), B(ref) at 0.33 B(rou)(,) max. uncertainty (U(max)) at 0.33 B(ref). The established specifications ranged between CV(rou)model 3) and CV(rou)model 2, monitoring). Model 2 (monitoring) gave the most stringent goals, model 3, the most liberal ones. Accounting for state-of-the-art performance and certification capabilities, we used model 2 (RI) to recommend achievable goals: for routine testing, CV(rou)measurements, CV(ref)

  10. Implementation of quality management systems and progress towards accreditation of National Tuberculosis Reference Laboratories in Africa

    Directory of Open Access Journals (Sweden)

    Heidi Albert

    2017-03-01

    Full Text Available Background: Laboratory services are essential at all stages of the tuberculosis care cascade, from diagnosis and drug resistance testing to monitoring response to treatment. Enabling access to quality services is a challenge in low-resource settings. Implementation of a strong quality management system (QMS and laboratory accreditation are key to improving patient care. Objectives: The study objective was to determine the status of QMS implementation and progress towards accreditation of National Tuberculosis Reference Laboratories (NTRLs in the African Region. Method: An online questionnaire was administered to NTRL managers in 47 World Health Organization Regional Office for Africa member states in the region, between February and April 2015, regarding the knowledge of QMS tools and progress toward implementation to inform strategies for tuberculosis diagnostic services strengthening in the region. Results: A total of 21 laboratories (43.0% had received SLMTA/TB-SLMTA training, of which 10 had also used the Global Laboratory Initiative accreditation tool. However, only 36.7% of NTRLs had received a laboratory audit, a first step in quality improvement. Most NTRLs participated in acid-fast bacilli microscopy external quality assurance (95.8%, although external quality assurance for other techniques was lower (60.4% for first-line drug susceptibility testing, 25.0% for second-line drug susceptibility testing, and 22.9% for molecular testing. Barriers to accreditation included lack of training and accreditation programmes. Only 28.6%of NTRLs had developed strategic plans and budgets which included accreditation. Conclusion: Good foundations are in place on the continent from which to scale up accreditation efforts. Laboratory audits should be conducted as a first step in developing quality improvement action plans. Political commitment and strong leadership are needed to drive accreditation efforts; advocacy will require clear evidence of patient

  11. JTRF2014, the JPL Kalman filter and smoother realization of the International Terrestrial Reference System

    Science.gov (United States)

    Abbondanza, Claudio; Chin, Toshio M.; Gross, Richard S.; Heflin, Michael B.; Parker, Jay W.; Soja, Benedikt S.; van Dam, Tonie; Wu, Xiaoping

    2017-10-01

    We present and discuss JTRF2014, the Terrestrial Reference Frame (TRF) the Jet Propulsion Laboratory constructed by combining space-geodetic inputs from very long baseline interferometry (VLBI), satellite laser ranging (SLR), Global Navigation Satellite Systems (GNSS), and Doppler orbitography and radiopositioning integrated by satellite submitted for the realization of ITRF2014. Determined through a Kalman filter and Rauch-Tung-Striebel smoother assimilating position observations, Earth orientation parameters, and local ties, JTRF2014 is a subsecular, time series-based TRF whose origin is at the quasi-instantaneous center of mass (CM) as sensed by SLR and whose scale is determined by the quasi-instantaneous VLBI and SLR scales. The dynamical evolution of the positions accounts for a secular motion term, annual, and semiannual periodic modes. Site-dependent variances based on the analysis of loading displacements induced by mass redistributions of terrestrial fluids have been used to control the extent of random walk adopted in the combination. With differences in the amplitude of the annual signal within the range 0.5-0.8 mm, JTRF2014-derived center of network-to-center of mass (CM-CN) is in remarkable agreement with the geocenter motion obtained via spectral inversion of GNSS, Gravity Recovery and Climate Experiment (GRACE) observations and modeled ocean bottom pressure from Estimating the Circulation and Climate of the Ocean (ECCO). Comparisons of JTRF2014 to ITRF2014 suggest high-level consistency with time derivatives of the Helmert transformation parameters connecting the two frames below 0.18 mm/yr and weighted root-mean-square differences of the polar motion (polar motion rate) in the order of 30 μas (17 μas/d).

  12. The digital bee brain: integrating and managing neurons in a common 3D reference system

    Directory of Open Access Journals (Sweden)

    Jürgen Rybak

    2010-07-01

    Full Text Available The honeybee standard brain (HSB serves as an interactive tool for relating morphologies of bee brain neurons and provides a reference system for functional and bibliographical properties (http://www.neurobiologie.fu-berlin.de/beebrain/. The ultimate goal is to document not only the morphological network properties of neurons collected from separate brains, but also to establish a graphical user interface for a neuron-related data base. Here, we review the current methods and protocols used to incorporate neuronal reconstructions into the HSB. Our registration protocol consists of two separate steps applied to imaging data from two-channel confocal microscopy scans: (1 The reconstruction of the neuron, facilitated by an automatic extraction of the neuron’s skeleton based on threshold segmentation, and (2 the semi-automatic 3D segmentation of the neuropils and their registration with the HSB. The integration of neurons in the HSB is performed by applying the transformation computed in step (2 to the reconstructed neurons of step (1. The most critical issue of this protocol in terms of user interaction time – the segmentation process – is drastically improved by the use of a model-based segmentation process. Furthermore, the underlying statistical shape models (SSM allow the visualization and analysis of characteristic variations in large sets of bee brain data. The anatomy of neural networks composed of multiple neurons that are registered into the HSB are visualized by depicting the 3D reconstructions together with semantic information with the objective to integrate data from multiple sources (electrophysiology, imaging, immunocytochemistry, molecular biology. Ultimately, this will allow the user to specify cell types and retrieve their morphologies along with physiological characterizations.

  13. Central nervous system imaging in childhood Langerhans cell histiocytosis – a reference center analysis

    International Nuclear Information System (INIS)

    Porto, Luciana; Schöning, Stefan; Hattingen, Elke; Sörensen, Jan; Jurcoane, Alina; Lehrnbecher, Thomas

    2015-01-01

    The aim of our study was (1) to describe central nervous system (CNS) manifestations in children with Langerhans cell histiocytosis (LCH) based on images sent to a reference center and meeting minimum requirements and (2) to assess the inter-rater agreement of CNS-MRI results, which represents the overall reproducibility of this investigation. We retrospectively reviewed brain MRI examinations in children with LCH, for which MRI minimum requirements were met. Abnormalities were rated by two experienced neuroradiologists, and the inter-rater agreement was assessed. Out of a total of 94 imaging studies, only 31 MRIs met the minimum criteria, which included T2w, FLAIR, T1w images before/after contrast in at least two different section planes, and thin post contrast sagittal slices T1w through the sella. The most common changes were osseous abnormalities, followed by solid enlargement of the pineal gland, thickened enhancing stalk and signal changes of the dentate nucleus. Whereas inter-rater agreement in assessing most of the CNS lesions was relatively high (κ > 0.61), the application of minimum criteria often did not allow to evaluate the posterior pituitary. The diversity of radiological protocols from different institutions leads to difficulties in the diagnosis of CNS abnormalities in children with LCH. Although the inter-rater agreement between neuroradiologists was high, not all the LCH manifestations could be completely ruled out when using the minimum criteria. Brain MRIs should therefore follow LCH guideline protocols and include T1 pre-gadolinium sagittal images, and be centrally reviewed in order to improve the comparison of clinical trials

  14. A multi-physics modelling framework to describe the behaviour of nano-scale multilayer systems undergoing irradiation damage

    International Nuclear Information System (INIS)

    Villani, Aurelien

    2015-01-01

    Radiation damage is known to lead to material failure and thus is of critical importance to lifetime and safety within nuclear reactors. While mechanical behaviour of materials under irradiation has been the subject of numerous studies, the current predictive capabilities of such phenomena appear limited. The clustering of point defects such as vacancies and self interstitial atoms gives rise to creep, void swelling and material embrittlement. Nano-scale metallic multilayer systems have be shown to have the ability to evacuate such point defects, hence delaying the occurrence of critical damage. In addition, they exhibit outstanding mechanical properties. The objective of this work is to develop a thermodynamically consistent continuum framework at the meso and nano-scales, which accounts for the major physical processes encountered in such metallic multilayer systems and is able to predict their microstructural evolution and behavior under irradiation. Mainly three physical phenomena are addressed in the present work: stress-diffusion coupling and diffusion induced creep, the void nucleation and growth in multilayer systems under irradiation, and the interaction of dislocations with the multilayer interfaces. In this framework, the microstructure is explicitly modeled, in order to account accurately for their effects on the system behavior. The diffusion creep strain rate is related to the gradient of the vacancy flux. A Cahn-Hilliard approach is used to model void nucleation and growth, and the diffusion equations for vacancies and self interstitial atoms are complemented to take into account the production of point defects due to irradiation cascades, the mutual recombination of defects and their evacuation through grain boundaries. In metallic multilayers, an interface affected zone is defined, with an additional slip plane to model the interface shearable character, and where dislocations cores are able to spread. The model is then implemented numerically

  15. Assessment of a dynamic reference material for calibration of full-field measurement systems

    Science.gov (United States)

    Hack, Erwin; Feligiotti, Mara; Davighi, Andrea; Whelan, Maurice; Wang, Weizhuo V.; Patterson, Eann A.

    2012-10-01

    For holography and speckle interferometry the calibration of the sensitivity is a must, because illumination and observation directions vary across the field of view. A numerical estimate or a static calibration using rigid body motions is standard, and reference materials exist for static strain calibration. Recently, reference materials for the dynamic calibration of optical instruments of displacement and strain measurement were designed and prototypes were manufactured in the European FP7 project ADVISE. We review the properties of the reference material and the concept of traceability for the field of displacement values by using a calibrated single point transducer. The mode shape is assessed using out-of-plane DSPI, Finite Element Analysis as well as analytic solutions of the plate vibration. We present measurements using stroboscopic DSPI on the reference material under acoustic excitation and compare the measured mode shapes to the ones predicted by FE analysis. We apply different comparison methodologies based on point-by-point deviations and on decomposition of the mode shapes into a set of orthogonal basis functions. The latter method is well suited to assess stability and reproducibility of a mode shape. Finally, the deviations are used to estimate the reference material uncertainty which is an essential parameter for determining the calibration uncertainty. Uncertainty contributions of the DSPI set-up are taken into account. To conclude, the application area and limitations of the reference material are discussed.

  16. Democracy and environment as references for quadruple and quintuple helix innovation systems

    Science.gov (United States)

    Carayannis, Elias G.; Campbell, David F. J.; Orr, Barron J.

    2015-04-01

    The perspective of democracy and the ecological context define key references for knowledge production and innovation in innovation systems. Particularly under conditions of environmental change where enhancing the potential for adaptation is critical, this requires a closer look at ecological responsibility and sensitivity in the different innovation models and governance regimes. The "Quintuple Helix" innovation model is an approach that stresses the necessary socio-ecological transition of society and economy by adding an environment helix to an innovation system already made up of three (university-industry-government) or four (civil society relations) helices in a way that supports adaptation by incorporating global warming as both a challenge to and a driver of innovation. There is the proposition that knowledge production and innovation co-evolve with democracy (Carayannis and Campbell, 2014). In the Triple Helix model (Etzkowitz and Leydesdorff, 2000) the existence of a democracy does not appear to be necessary for knowledge production and innovation. However, the Quadruple Helix (Carayannis and Campbell, 2009, 2010 and 2014) is defined and represented by additional key attributes and components: "media-based and culture-based public", "civil society" and "arts, artistic research and arts-based innovation" (Bast, Carayannis and Campbell, 2015). Implications of this are that the fourth helix in the Quadruple Helix innovation systems brings in and represents the perspective of "dimension of democracy" or the "context of democracy" for knowledge in general and knowledge production and innovation in more particular. Within theories of democracy there is a competition between narrow and broader concepts of democracy (Campbell, 2013). This is particularly true when democracy is to be understood to transcend more substantially the narrow understanding of being primarily based on or being primarily rooted in government institutions (within a Triple Helix

  17. 36. Anesthesia for high risk patients undergoing percutaneous mitral valve repair with the mitraclip system in the catheterization laboratory

    Directory of Open Access Journals (Sweden)

    R. Soliman

    2016-07-01

    Full Text Available MitraClip system implantation is used inhigh-risk patients with severe mitral regurgitation.anesthetic management for mitral clip implantation. The study included 34patients scheduled for MitraClip implantations in the catheterization laboratory. An arterial line and central venous line were inserted under local anesthesia before induction. Epinephrine was started before induction and milrinone infusion was started after induction. The anesthetic technique for induction and maintenance was the same for all patients. All patients were hemodynamically stable intra- and postoperatively. The intervention was successful in 33 cases and aborted in one case because of severe posteromedial leaflet tethering. The epinephrine and milrinone were weaned and all patients were extubated, except, one case mortality happened within the first 8 hours postoperatively. Percutaneous mitral valve repair with MitraClip implantation is a successful alternative in high-risk patients with symptomatic severe mitral regurgitation. Starting epinephrine before anesthetic induction and milrinone infusion induction resulted in decreased pulmonary artery pressure, increased ejection fraction and maintained arterial blood pressure during procedure inspite of worse preoperative conditions.

  18. Landscape changes in a coastal system undergoing tourism development: implications for Barra de Navidad Lagoon, Jalisco, Mexico

    Directory of Open Access Journals (Sweden)

    Tara L. Holland

    2012-02-01

    Full Text Available In this study, changes in land cover and land use patterns that occurred between 1985 and 2000 in the surrounding basin of the Barra de Navidad coastal lagoon in Jalisco, Mexico are quantified and explained. Two satellite images from 1985 (Landsat TM and 2000 (Landsat ETM+ were analyzed with supervised classification and ground truthing to evaluate changes in six land use/cover categories: lagoon, agriculture, urban/tourist, tropical dry forest, mangrove and bare substratum. Changes in land use composition were evaluated using a transition matrix and changes to configuration were interpreted using landscape metrics. Results show that urban and tourist areas expanded between 1985 and 2000, mostly at the expense of forested and bare land. Mangroves showed a large relative decrease in area (-39% and experienced fragmentation. These changes appear to be related to increased sedimentation a fan progradation into Barra de Navidad lagoon. These results may serve as a model for comparison in other systems experiencing multiple stressors, especially changes related to tourism and the intensification of resource extraction.

  19. Development of solid state reference electrodes and pH sensors for monitoring nuclear reactor cooling water systems

    International Nuclear Information System (INIS)

    Hettiarachchi, S.; Makela, K.; Macdonald, D.D.

    1991-01-01

    The growing interest in the electrochemical and corrosion behavior of structural alloys in high temperature aqueous systems has stimulated research in the design and testing of reliable reference electrodes and pH sensors for use in such environments. External reference electrodes have been successfully used in the recent years in high temperature aqueous environments, although their long-term stability is questionable. On the other hand, more reliable pH sensors have been developed by various workers for high temperature applications, the major drawback being their sensitivity to dissolved hydrogen, oxygen and other redox species. This paper describes the development of both solid-state reference electrodes and yttria-stabilized zirconia (YSZ) pH sensors for application in high temperature aqueous systems. (author)

  20. Effects of Addition of Systemic Tramadol or Adjunct Tramadol to Lidocaine Used for Intravenous Regional Anesthesia in Patients Undergoing Hand Surgery

    Directory of Open Access Journals (Sweden)

    Abdulkadir Yektaş

    2016-01-01

    Full Text Available Intravenous regional anesthesia (IVRA is used in outpatient hand surgery as an easily applicable and cost-effective technique with clinical advantages. The present study aimed to investigate the effects of addition of systemic tramadol or adjunct tramadol to lidocaine for IVRA in patients undergoing hand surgery. American Society of Anesthesiologists (ASA I-II patients (n=60 who underwent hand surgery were included. For this purpose, only lidocaine (LDC, lidocaine+adjunct tramadol (LDC+TRA group, or lidocaine+systemic tramadol (LDC+SysTRA group was administered to the patients for IVRA and the groups were compared in terms of onset and recovery time of sensory and motor blocks, quality of anesthesia, and the degree of intraoperative and postoperative pain. The onset time of sensorial block was significantly shorter in the LDC+TRA group than that in the LDC+SysTRA group. The motor block recovery time was significantly shorter in the LDC+SysTRA group than that in the LDC+TRA and LDC groups. Administration of tramadol as an adjunct showed some clinical benefits by providing a shorter onset time of sensory and motor block, decreasing pain and analgesic requirement, and improving intraoperative conditions during IVRA. It was determined that systemic tramadol administration had no superiority.

  1. REFERENCE MATERIALS SYSTEM OF SCIENTIFIC METHODICAL CENTRE OF STATE SERVICE OF REFERENCE MATERIALS FOR COMPOSITION AND PROPERTIES OF SUBSTANCES AND MATERIALS URAL RESEARCH INSTITUTE FOR METROLOGY

    Directory of Open Access Journals (Sweden)

    E. V. Osinseva

    2015-01-01

    Full Text Available Since 1960s UNIIM performs research in the field of needs in reference materials of composition and properties of substances and materials (RM as well as develops it. During the research UNIIM has developed 757 types of RMs for metrological measurement assurance of factors of composition and properties of substance and materials for test laboratories of chemical, pharmaceutical, fuel, food industry, agriculture, metallurgy and ecological monitoring laboratories. List ofRMs enlarges thanks to development of UNIIM standards and transmission measurement facility from State standards of units. Taking into account the actual requirements in the field of measurements, the UNIIM's key destination is to assure the accuracy and the metrological traceability of measurements. The present-day system of RMs to be developed in UNIIM includes RMs of composition of inorganic and organic compounds and their solutions, fuels, stable isotopic materials, water, grounds, food products, biomaterials, nanomaterials, metals, alloys and other materials offerrous and non-ferrous industry, RMs of properties (thermodynamic, magnetic, physical-chemical, technical of substances and materials. The present article considers history of RMs list development which were created by UNIIM and the strategy of this direction.

  2. An Attitude Heading and Reference System For Marine Satellite Tracking Antenna

    DEFF Research Database (Denmark)

    Wang, Yunlong; Soltani, Mohsen; Hussain, Dil muhammed Akbar

    2017-01-01

    One of the most challenging problems for marine satellite tracking antennas (MSTAs) is to estimate the antenna attitude, which is affected by the ship motion, especially the ship vibration and rotational motions caused by ocean waves. To overcome this problem, an attitude heading and reference...... conditions, an attitude estimator based on virtual horizontal reference is introduced for situations of accelerometer malfunction, where the ship is suffering from wave shocks in high sea states. The performance of the designed AHRS for MSTA is assessed through hardware experiments using a Stewart platform...

  3. Systems Analysis Programs for Hands-on Integrated Reliability Evaluations (SAPHIRE) Code Reference Manual

    Energy Technology Data Exchange (ETDEWEB)

    C. L. Smith; K. J. Kvarfordt; S. T. Wood

    2008-08-01

    The Systems Analysis Programs for Hands-on Integrated Reliability Evaluations (SAPHIRE) is a software application developed for performing a complete probabilistic risk assessment (PRA) using a personal computer. SAPHIRE is funded by the U.S. Nuclear Regulatory Commission (NRC) and developed by the Idaho National Laboratory (INL). The INL's primary role in this project is that of software developer. However, the INL also plays an important role in technology transfer by interfacing and supporting SAPHIRE users comprised of a wide range of PRA practitioners from the NRC, national laboratories, the private sector, and foreign countries. SAPHIRE can be used to model a complex system’s response to initiating events, quantify associated damage outcome frequencies, and identify important contributors to this damage (Level 1 PRA) and to analyze containment performance during a severe accident and quantify radioactive releases (Level 2 PRA). It can be used for a PRA evaluating a variety of operating conditions, for example, for a nuclear reactor at full power, low power, or at shutdown conditions. Furthermore, SAPHIRE can be used to analyze both internal and external initiating events and has special features for transforming models built for internal event analysis to models for external event analysis. It can also be used in a limited manner to quantify risk in terms of release consequences to both the public and the environment (Level 3 PRA). SAPHIRE includes a separate module called the Graphical Evaluation Module (GEM). GEM provides a highly specialized user interface with SAPHIRE that automates SAPHIRE process steps for evaluating operational events at commercial nuclear power plants. Using GEM, an analyst can estimate the risk associated with operational events in a very efficient and expeditious manner. This reference guide will introduce the SAPHIRE Version 7.0 software. A brief discussion of the purpose and history of the software is included along with

  4. Systems Analysis Programs for Hands-on Integrated Reliability Evaluations (SAPHIRE) Code Reference Manual

    Energy Technology Data Exchange (ETDEWEB)

    C. L. Smith; K. J. Kvarfordt; S. T. Wood

    2006-07-01

    The Systems Analysis Programs for Hands-on Integrated Reliability Evaluations (SAPHIRE) is a software application developed for performing a complete probabilistic risk assessment (PRA) using a personal computer. SAPHIRE is funded by the U.S. Nuclear Regulatory Commission (NRC) and developed by the Idaho National Laboratory (INL). The INL's primary role in this project is that of software developer. However, the INL also plays an important role in technology transfer by interfacing and supporting SAPHIRE users comprised of a wide range of PRA practitioners from the NRC, national laboratories, the private sector, and foreign countries. SAPHIRE can be used to model a complex system’s response to initiating events, quantify associated damage outcome frequencies, and identify important contributors to this damage (Level 1 PRA) and to analyze containment performance during a severe accident and quantify radioactive releases (Level 2 PRA). It can be used for a PRA evaluating a variety of operating conditions, for example, for a nuclear reactor at full power, low power, or at shutdown conditions. Furthermore, SAPHIRE can be used to analyze both internal and external initiating events and has special features for ansforming models built for internal event analysis to models for external event analysis. It can also be used in a limited manner to quantify risk in terms of release consequences to both the public and the environment (Level 3 PRA). SAPHIRE includes a separate module called the Graphical Evaluation Module (GEM). GEM provides a highly specialized user interface with SAPHIRE that automates SAPHIRE process steps for evaluating operational events at commercial nuclear power plants. Using GEM, an analyst can estimate the risk associated with operational events in a very efficient and expeditious manner. This reference guide will introduce the SAPHIRE Version 7.0 software. A brief discussion of the purpose and history of the software is included along with

  5. Prediction of Change in Prescription Ingredient Costs and Co-payment Rates under a Reference Pricing System in South Korea.

    Science.gov (United States)

    Heo, Ji Haeng; Rascati, Karen L; Lee, Eui-Kyung

    2017-05-01

    The reference pricing system (RPS) establishes reference prices within interchangeable reference groupings. For drugs priced higher than the reference point, patients pay the difference between the reference price and the total price. To predict potential changes in prescription ingredient costs and co-payment rates after implementation of an RPS in South Korea. Korean National Health Insurance claims data were used as a baseline to develop possible RPS models. Five components of a potential RPS policy were varied: reference groupings, reference pricing methods, co-pay reduction programs, manufacturer price reductions, and increased drug substitutions. The potential changes for prescription ingredient costs and co-payment rates were predicted for the various scenarios. It was predicted that transferring the difference (total price minus reference price) from the insurer to patients would reduce ingredient costs from 1.4% to 22.8% for the third-party payer (government), but patient co-payment rates would increase from a baseline of 20.4% to 22.0% using chemical groupings and to 25.0% using therapeutic groupings. Savings rates in prescription ingredient costs (government and patient combined) were predicted to range from 1.6% to 13.7% depending on various scenarios. Although the co-payment rate would increase, a 15% price reduction by manufacturers coupled with a substitution rate of 30% would result in a decrease in the co-payment amount (change in absolute dollars vs. change in rates). Our models predicted that the implementation of RPS in South Korea would lead to savings in ingredient costs for the third-party payer and co-payments for patients with potential scenarios. Copyright © 2017 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.

  6. An improved synchronous reference frame phase-locked loop for stand-alone variable speed constant frequency power generation systems

    DEFF Research Database (Denmark)

    Liu, Yi; Xu, Wei; Ke, Longzhang

    2017-01-01

    The phase-locked loop (PLL) based on conventional synchronous reference frame, i.e. dqPLL, is usually employed in grid-connected variable speed constant frequency (VSCF) power generation systems (PGSs). However, the voltage amplitude drop of stand-alone PGSs is often greater than that of the grid...

  7. Prescribing during pregnancy and lactation with reference to the Swedish classification system - A population-based study among Danish women

    NARCIS (Netherlands)

    Olesen, C; Sorensen, HT; de Jong-van den Berg, L; Olsen, J; Steffensen, FH

    Aim. To assess the current prescribing pattern for 15,756 primiparae before, during, and after their pregnancies with reference to fetal and neonatal risk. Method. A prescription database study with linkage to The Danish Medical Birth Registry from 1991 to 1996. The drug subsidy system in Danish

  8. Assessment of the periodontal health status in patients undergoing orthodontic treatment with fixed appliances and Invisalign system: A meta-analysis.

    Science.gov (United States)

    Lu, Haili; Tang, Haifang; Zhou, Tian; Kang, Na

    2018-03-01

    At present, many scholars have studied the periodontal health status of patients undergoing orthodontic treatment with fixed appliances and invisalign. However, those results are inconsistent. Therefore, we conducted this meta-analysis, and then provide reference for clinical treatment. Most databases, such as the Cochrane Library, EMBASE, PubMed, Medline, Chinese Biomedical Literature Database, CNKI, and Wan Fang Data were retrieved for related articles from the establishment of the database to October 2017. Meanwhile, we also searched the references of the related literatures manually, in order to increase the included literatures. Two researchers screened the related literatures according to the inclusion criteria and exclusion criteria. Stata 12.0 software was used for data analysis, and results are estimated by odds ratio (OR) and 95% confidence interval (CI). Finally, 7 articles, including 368 patients, were included into our meta-analysis. Meta-analysis results showed that there was no statistically significant difference of gingival index (GI) and sulcus probing depth (SPD) status between the invisalign group and the control group, including at 1, 3, and 6 months (all P > .05). When compared with the control group, the invisalign group presented a lower plaque index (PLI) and sulcus bleeding index (SBI) status at 1 month (OR = -0.53, 95% CI: -0.89 to -0.18; OR = -0.44, 95% CI: -0.70 to -0.19, respectively), 3 months (OR = -0.69, 95% CI: -1.12 to -0.27; OR = -0.49, 95% CI: -0.93 to -0.05, respectively), and 6 months (OR = -0.91, 95% CI: -1.47 to -0.35; OR = -0.40, 95% CI: -0.63 to -0.07, respectively). Subgroup analysis showed that the SPD status was lower in the invisalign group at 6 months when measured the teeth using Ramfjord index (OR = -0.74, 95% CI: -1.35 to -0.12). However, there was no statistically significant difference between the 2 groups when using other measure methods (OR = 0.12, 95% CI: -0.26 to 0.17). Our

  9. Safety evaluation report related to the preliminary design of the Standard Reference System, RESAR-414

    International Nuclear Information System (INIS)

    1978-11-01

    The safety evaluation for the Westinghouse Standard Reactor includes information on general reactor characteristics; design criteria for systems and components; reactor coolant system; engineered safety systems; instrumentation and controls; electric power systems; auxiliary systems; steam and power conversion system; radioactive waste management; radiation protection; conduct of operations; accident analyses; and quality assurance

  10. Verification of status of reference of Brainscan planning system through Grafchromic EBT3

    International Nuclear Information System (INIS)

    Vazquez Vazquez, R.; Ambroa Rey, E. M.; Gimenez Insua, M.; Luna Vega, V.; Mosquera Sueiro, J.; Lobato Busto, R.; Sanchez Garcia, M.; Otero Martinez, C.; Pombar Camean, M.

    2013-01-01

    To compare the State of current of the Brainscan planner with the initial reference State has been successful. This new detector shows behavior similar to its predecessor (Gafchromic EBT2), but without the disadvantages arising from the construction of the same. (Author)

  11. Therapeutic Change in Colombian Families Dealing with Violence: Therapists, Clients, and Referring Systems in Conversation

    Science.gov (United States)

    Ripoll-Nunez, Karen; Villar-Guhl, Carlos Felipe; Villar-Concha, Eduardo

    2012-01-01

    There is a gap in the Marriage and Family Therapy literature regarding clients', therapists', and family judges' theories of change in relational therapy for family violence. We conducted in-depth interviews with eleven court-referred families, their therapists, and two family judges in Bogota, Colombia. Interviews focused on their expectations of…

  12. Development of human protein reference database as an initial platform for approaching systems biology in humans

    DEFF Research Database (Denmark)

    Peri, Suraj; Navarro, J Daniel; Amanchy, Ramars

    2003-01-01

    Human Protein Reference Database (HPRD) is an object database that integrates a wealth of information relevant to the function of human proteins in health and disease. Data pertaining to thousands of protein-protein interactions, posttranslational modifications, enzyme/substrate relationships...

  13. Multi-media communication system: Upper layers in the OSI reference model

    NARCIS (Netherlands)

    Zafirovic-Vukotic, M.; Niemegeers, I.G.M.M.

    1992-01-01

    The structuring, services, and major protocol functions that are required in the upper layers of the OSI reference model in order to support end-to-end multimedia communication, assuming a simple transport service, are examined. It is assumed that variable-bit-rate (VBR) coding techniques will be

  14. Effectiveness of Asynchronous Reference Services for Distance Learning Students within Florida's Community College System

    Science.gov (United States)

    Profeta, Patricia C.

    2007-01-01

    The provision of equitable library services to distance learning students emerged as a critical area during the 1990s. Library services available to distance learning students included digital reference and instructional services, remote access to online research tools, database and research tutorials, interlibrary loan, and document delivery.…

  15. Clinical Validation of the 2005 ISUP Gleason Grading System in a Cohort of Intermediate and High Risk Men Undergoing Radical Prostatectomy.

    Directory of Open Access Journals (Sweden)

    Sheila F Faraj

    Full Text Available In 2005, the International Society of Urological Pathology (ISUP introduced several modifications to the original Gleason system that were intended to enhance the prognostic power of Gleason score (GS. The objective of this study was to clinically validate the 2005 ISUP Gleason grading system for its ability to detect metastasis. We queried our institutional RP database for men with NCCN clinically localized intermediate to high-risk disease undergoing radical prostatectomy (RP between 1992 and 2010 with no additional treatment until the time of metastatic progression. A case-cohort design was utilized. A total of 333 available RP samples were re-reviewed and GS was reassigned per the 2005 ISUP Gleason system. Cumulative incidence of metastasis was 0%, 8.4%, 24.5% and 44.4% among specimens that were downgraded, unchanged, had one point GS increase and two point GS increase, respectively. The hazard ratio for metastasis raised in GS 8 and 9 compared to GS 7 from 2.77 and 5.91 to 3.49 and 9.31, respectively. The survival c-index of GS increased from 0.70 to 0.80 when samples were re-graded at 5 years post RP. The c-index of the reassigned GS was higher than the original GS (0.77 vs 0.64 for predicting PCSM at 10 years post RP. The regraded GS improved the prediction of metastasis and PCSM. This validates the updated Gleason grading system using an unambiguous clinical endpoint and highlights the need for reassignment of Gleason grading according to 2005 ISUP system when considering comparisons of novel biomarkers to clinicopathological variables in archival cohorts.

  16. Pediatric reference value distributions and covariate-stratified reference intervals for 29 endocrine and special chemistry biomarkers on the Beckman Coulter Immunoassay Systems: a CALIPER study of healthy community children.

    Science.gov (United States)

    Karbasy, Kimiya; Lin, Danny C C; Stoianov, Alexandra; Chan, Man Khun; Bevilacqua, Victoria; Chen, Yunqi; Adeli, Khosrow

    2016-04-01

    The CALIPER program is a national research initiative aimed at closing the gaps in pediatric reference intervals. CALIPER previously reported reference intervals for endocrine and special chemistry markers on Abbott immunoassays. We now report new pediatric reference intervals for immunoassays on the Beckman Coulter Immunoassay Systems and assess platform-specific differences in reference values. A total of 711 healthy children and adolescents from birth to reference intervals calculated in accordance with Clinical and Laboratory Standards Institute (CLSI) EP28-A3c guidelines. Complex profiles were observed for all 29 analytes, necessitating unique age and/or sex-specific partitions. Overall, changes in analyte concentrations observed over the course of development were similar to trends previously reported, and are consistent with biochemical and physiological changes that occur during childhood. Marked differences were observed for some assays including progesterone, luteinizing hormone and follicle-stimulating hormone where reference intervals were higher than those reported on Abbott immunoassays and parathyroid hormone where intervals were lower. This study highlights the importance of determining reference intervals specific for each analytical platform. The CALIPER Pediatric Reference Interval database will enable accurate diagnosis and laboratory assessment of children monitored by Beckman Coulter Immunoassay Systems in health care institutions worldwide. These reference intervals must however be validated by individual labs for the local pediatric population as recommended by CLSI.

  17. A Proposal of New Reference System for the Standard Axial, Sagittal, Coronal Planes of Brain Based on the Serially-Sectioned Images

    Science.gov (United States)

    Park, Jin Seo; Park, Hyo Seok; Shin, Dong Sun; Har, Dong-Hwan; Cho, Zang-Hee; Kim, Young-Bo; Han, Jae-Yong; Chi, Je-Geun

    2010-01-01

    Sectional anatomy of human brain is useful to examine the diseased brain as well as normal brain. However, intracerebral reference points for the axial, sagittal, and coronal planes of brain have not been standardized in anatomical sections or radiological images. We made 2,343 serially-sectioned images of a cadaver head with 0.1 mm intervals, 0.1 mm pixel size, and 48 bit color and obtained axial, sagittal, and coronal images based on the proposed reference system. This reference system consists of one principal reference point and two ancillary reference points. The two ancillary reference points are the anterior commissure and the posterior commissure. And the principal reference point is the midpoint of two ancillary reference points. It resides in the center of whole brain. From the principal reference point, Cartesian coordinate of x, y, z could be made to be the standard axial, sagittal, and coronal planes. PMID:20052359

  18. Analysis and comparison of NoSQL databases with an introduction to consistent references in big data storage systems

    Science.gov (United States)

    Dziedzic, Adam; Mulawka, Jan

    2014-11-01

    NoSQL is a new approach to data storage and manipulation. The aim of this paper is to gain more insight into NoSQL databases, as we are still in the early stages of understanding when to use them and how to use them in an appropriate way. In this submission descriptions of selected NoSQL databases are presented. Each of the databases is analysed with primary focus on its data model, data access, architecture and practical usage in real applications. Furthemore, the NoSQL databases are compared in fields of data references. The relational databases offer foreign keys, whereas NoSQL databases provide us with limited references. An intermediate model between graph theory and relational algebra which can address the problem should be created. Finally, the proposal of a new approach to the problem of inconsistent references in Big Data storage systems is introduced.

  19. Communication: Density functional theory model for multi-reference systems based on the exact-exchange hole normalization.

    Science.gov (United States)

    Laqua, Henryk; Kussmann, Jörg; Ochsenfeld, Christian

    2018-03-28

    The correct description of multi-reference electronic ground states within Kohn-Sham density functional theory (DFT) requires an ensemble-state representation, employing fractionally occupied orbitals. However, the use of fractional orbital occupation leads to non-normalized exact-exchange holes, resulting in large fractional-spin errors for conventional approximative density functionals. In this communication, we present a simple approach to directly include the exact-exchange-hole normalization into DFT. Compared to conventional functionals, our model strongly improves the description for multi-reference systems, while preserving the accuracy in the single-reference case. We analyze the performance of our proposed method at the example of spin-averaged atoms and spin-restricted bond dissociation energy surfaces.

  20. Communication: Density functional theory model for multi-reference systems based on the exact-exchange hole normalization

    Science.gov (United States)

    Laqua, Henryk; Kussmann, Jörg; Ochsenfeld, Christian

    2018-03-01

    The correct description of multi-reference electronic ground states within Kohn-Sham density functional theory (DFT) requires an ensemble-state representation, employing fractionally occupied orbitals. However, the use of fractional orbital occupation leads to non-normalized exact-exchange holes, resulting in large fractional-spin errors for conventional approximative density functionals. In this communication, we present a simple approach to directly include the exact-exchange-hole normalization into DFT. Compared to conventional functionals, our model strongly improves the description for multi-reference systems, while preserving the accuracy in the single-reference case. We analyze the performance of our proposed method at the example of spin-averaged atoms and spin-restricted bond dissociation energy surfaces.

  1. On correlation comparison of identical pions in different systems of reference

    International Nuclear Information System (INIS)

    Podgoretskij, M.I.

    1983-01-01

    It is shown that a comparison of correlations of identical pions in reference frames moving with different velocities along the reaction axis enables one to select the frame for which there is a kinematical symmetry in the multiple generation process. The indicated possibility is due to the fact that in the considered symmetrical frame the space-time parameters R and tau are extremal. An experimental selection of the ''symmetrical frame'' may be useful in the choice between competing models of multiple generation

  2. References for HNF-SD-WM-TRD-007, ''System specification for the double-shell tank system: HNF-PROs, CFRs, DOE Orders, WACs''

    International Nuclear Information System (INIS)

    Shaw, C.P.

    1998-01-01

    HNF-SD-WM-TRD-O07, System Specification for the Double-Shell Tank System, (hereafter referred to as DST Specification), defines the requirements of the double-shell tank system at the Hanford Site for Phase 1 privatization. Many of the sections in this document reference other documents for design guidance and requirements. Referenced documents include Project Hanford Management Contract (PHMC) procedures (HNF-PROS), Codes of Federal Regulation (CFRs), DOE Orders, and Washington Administrative Codes (WACs). This document provides rationale for the selection and inclusion of HNF-PROS, CFRs, DOE Orders and WACs

  3. The relationship between right-sided tumour location, tumour microenvironment, systemic inflammation, adjuvant therapy and survival in patients undergoing surgery for colon and rectal cancer.

    Science.gov (United States)

    Patel, Meera; McSorley, Stephen T; Park, James H; Roxburgh, Campbell S D; Edwards, Joann; Horgan, Paul G; McMillan, Donald C

    2018-03-06

    There has been an increasing interest in the role of tumour location in the treatment and prognosis of patients with colorectal cancer (CRC), specifically in the adjuvant setting. Together with genomic data, this has led to the proposal that right-sided and left-sided tumours should be considered as distinct biological and clinical entities. The aim of the present study was to examine the relationship between tumour location, tumour microenvironment, systemic inflammatory response (SIR), adjuvant chemotherapy and survival in patients undergoing potentially curative surgery for stage I-III colon and rectal cancer. Clinicopathological characteristics were extracted from a prospective database. MMR and BRAF status was determined using immunohistochemistry. The tumour microenvironment was assessed using routine H&E pathological sections. SIR was assessed using modified Glasgow Prognostic Score (mGPS), neutrophil:lymphocyte ratio (NLR), neutrophil:platelet score (NPS) and lymphocyte:monocyte ratio (LMR). Overall, 972 patients were included. The majority were over 65 years (68%), male (55%), TNM stage II/III (82%). In all, 40% of patients had right-sided tumours and 31% had rectal cancers. Right-sided tumour location was associated with older age (P=0.001), deficient MMR (P=0.005), higher T stage (Plocation was consistently associated with a high SIR, mGPS (Plocation, adjuvant chemotherapy (P=0.632) or cancer-specific survival (CSS; P=0.377). In those 275 patients who received adjuvant chemotherapy, right-sided location was not associated with the MMR status (P=0.509) but was associated with higher T stage (P=0.001), venous invasion (P=0.036), CD3 + at the invasive margin (P=0.033) and CD3 + within cancer nests (P=0.012). There was no relationship between tumour location, SIR or CSS in the adjuvant group. Right-sided tumour location was associated with an elevated tumour lymphocytic infiltrate and an elevated SIR. There was no association between tumour location and

  4. Estimating the Reference Incremental Cost-Effectiveness Ratio for the Australian Health System.

    Science.gov (United States)

    Edney, Laura Catherine; Haji Ali Afzali, Hossein; Cheng, Terence Chai; Karnon, Jonathan

    2018-02-01

    Spending on new healthcare technologies increases net population health when the benefits of a new technology are greater than their opportunity costs-the benefits of the best alternative use of the additional resources required to fund a new technology. The objective of this study was to estimate the expected incremental cost per quality-adjusted life-year (QALY) gained of increased government health expenditure as an empirical estimate of the average opportunity costs of decisions to fund new health technologies. The estimated incremental cost-effectiveness ratio (ICER) is proposed as a reference ICER to inform value-based decision making in Australia. Empirical top-down approaches were used to estimate the QALY effects of government health expenditure with respect to reduced mortality and morbidity. Instrumental variable two-stage least-squares regression was used to estimate the elasticity of mortality-related QALY losses to a marginal change in government health expenditure. Regression analysis of longitudinal survey data representative of the general population was used to isolate the effects of increased government health expenditure on morbidity-related, QALY gains. Clinical judgement informed the duration of health-related quality-of-life improvement from the annual increase in government health expenditure. The base-case reference ICER was estimated at AUD28,033 per QALY gained. Parametric uncertainty associated with the estimation of mortality- and morbidity-related QALYs generated a 95% confidence interval AUD20,758-37,667. Recent public summary documents suggest new technologies with ICERs above AUD40,000 per QALY gained are recommended for public funding. The empirical reference ICER reported in this article suggests more QALYs could be gained if resources were allocated to other forms of health spending.

  5. Towards a reference architecture for a collaborative intelligent transport system infrastructure

    NARCIS (Netherlands)

    Osório, A.L.; Afsarmanesh, H.; Camarinha-Matos, L.M.

    2010-01-01

    The intelligent transport systems, which aim at providing smarter transport infrastructures and sustainable mobility, are deeply grounded on the Information and Communication Technologies. Current trends in the development of integrated complex systems, such as integrated road/highway concessions

  6. Reference Sources in Chemistry

    OpenAIRE

    Sthapit, Dilip Man

    1995-01-01

    Information plays an important role in the development of every field. Therefore a brief knowledge regarding information sources is necessary to function in any field. There are many information sources about scientific and technical subjects. In this context there are many reference sources in Chemistry too. Chemistry is one important part of the science which deals with the study of the composition of substances and the chemical changes that they undergo. The purpose of this report is...

  7. A Software Reference Architecture for Service-Oriented 3D Geovisualization Systems

    OpenAIRE

    Hildebrandt, Dieter

    2014-01-01

    Modern 3D geovisualization systems (3DGeoVSs) are complex and evolving systems that are required to be adaptable and leverage distributed resources, including massive geodata. This article focuses on 3DGeoVSs built based on the principles of service-oriented architectures, standards and image-based representations (SSI) to address practically relevant challenges and potentials. Such systems facilitate resource sharing and agile and efficient system construction and change in an interoperable ...

  8. Self-Reference as a Problem in the Control of Complex Systems

    DEFF Research Database (Denmark)

    Hollnagel, Erik; Lind, Morten

    1982-01-01

    as cognitive systems. A distinction is made between 2 types of self-reflectivity: (1) outer-oriented reflectivity, which uses knowledge about the self and reactions from other systems as a basis for relevant adjustments; and (2) inner-oriented reflectivity, which the system realizes it already possesses. Both...

  9. A reference sample for investigating the stability of the imaging system of x-ray computed tomography

    International Nuclear Information System (INIS)

    Sun, Wenjuan; Brown, Stephen; Flay, Nadia; McCarthy, Michael; McBride, John

    2016-01-01

    The use of x-ray computed tomography for dimensional measurements associated with engineering applications has flourished in recent years. However, error sources associated with the technology are not well understood. In this paper, a novel two-sphere reference sample has been developed and used to investigate the stability of the imaging system that consists of an x-ray tube and a detector. In contrast with other research work reported, this work considered relative positional variation along the x -, y - and z -axes. This sample is a significant improvement over the one sphere sample proposed previously, which can only be used to observe the stability of the imaging system along x - and y -axes. Temperature variations of different parts of the system have been monitored and the relationship between temperature variations and x-ray image stability has been studied. Other effects that may also influence the stability of the imaging system have been discussed. The proposed reference sample and testing method are transferable to other types of x-ray computed tomography systems, for example, systems with transmission targets and systems with sub-micrometre focal spots. (paper)

  10. Structure factor of liquid alkali metals using a classical-plasma reference system

    Science.gov (United States)

    Pastore, G.; Tosi, M. P.

    1984-06-01

    This paper presents calculations of the liquid structure factor of the alkali metals near freezing, starting from the classical plasma of bare ions as reference liquid. The indirect ion-ion interaction arising from electronic screening is treated by an optimized random phase approximation (ORPA), imposing physical requirements as in the original ORPA scheme developed by Weeks, Chandler and Andersen for liquids with strongly repulsive core potentials. A comparison of the results with computer simulation data for a model of liquid rubidium shows that the present approach overcomes the well-known difficulties met in applying to these metals the standard ORPA based on a reference liquid of neutral hard spheres. The optimization scheme is also shown to be equivalent to a reduction of the range of the indirect interaction in momentum space, as proposed empirically in an earlier work. Comparison with experiment for the other alkalis shows that a good overall representation of the data can be obtained for sodium, potassium and cesium, but not for lithium, when one uses a very simple form of the electron-ion potential adjusted to the liquid compressibility. The small-angle scattering region is finally examined more carefully in the light of recent data of Waseda, with a view to possible refinements of the pseudopotential model.

  11. Contributions to reference systems from Lunar Laser Ranging using the IfE analysis model

    Science.gov (United States)

    Hofmann, Franz; Biskupek, Liliane; Müller, Jürgen

    2018-01-01

    Lunar Laser Ranging (LLR) provides various quantities related to reference frames like Earth orientation parameters, coordinates and velocities of ground stations in the Earth-fixed frame and selenocentric coordinates of the lunar retro-reflectors. This paper presents the recent results from LLR data analysis at the Institut für Erdmessung, Leibniz Universität Hannover, based on all LLR data up to the end of 2016. The estimates of long-periodic nutation coefficients with periods between 13.6 days and 18.6 years are obtained with an accuracy in the order of 0.05-0.7 milliarcseconds (mas). Estimations of the Earth rotation phase Δ UT are accurate at the level of 0.032 ms if more than 14 normal points per night are included. The tie between the dynamical ephemeris frame to the kinematic celestial frame is estimated from pure LLR observations by two angles and their rates with an accuracy of 0.25 and 0.02 mas per year. The estimated station coordinates and velocities are compared to the ITRF2014 solution and the geometry of the retro-reflector network with the DE430 solution. The given accuracies represent 3 times formal errors of the parameter fit. The accuracy for Δ UT is based on the standard deviation of the estimates with respect to the reference C04 solution.

  12. Reference design of the power supply system for the resistive-wall-mode control in JT-60SA

    Energy Technology Data Exchange (ETDEWEB)

    Ferro, Alberto, E-mail: alberto.ferro@igi.cnr.it [Consorzio RFX, C.so Stati Uniti 4, 35127 Padova (Italy); Gaio, Elena [Consorzio RFX, C.so Stati Uniti 4, 35127 Padova (Italy); Novello, Luca [Fusion for Energy, Broader Development of Fusion Department, Boltzmannstr 2, 85748 Garching (Germany); Matsukawa, Makoto; Shimada, Katsuhiro; Kawamata, Yoichi; Takechi, Manabu [Japan Atomic Energy Agency, Naka Fusion Institute, 801-1 Mukoyama, Naka, Ibaraki 311-019 (Japan)

    2015-10-15

    Highlights: • In JT-60SA, a power supply system (RWM-PS) will feed 18 coils to control the RWMs. • One power amplifier per coil will follow an arbitrary real-time reference. • Very fast dynamics is required (current bandwidth: 3 kHz; latency: 50 μs). • The requirements of the RWM-PS are updated and design solutions discussed. • The reference design of the RWM-PS is based on H-bridges operated at 20 – 30 kHz. - Abstract: The mission of JT-60SA, the satellite Tokamak under construction in Naka (Japan), includes the attainment of steady-state high-beta plasmas. For this purpose, an active control system based on 18 in-vessel sector coils (SC) is foreseen to suppress the resistive wall modes (RWM). Each coil will be independently fed by a dedicated converter, rated for 300 A and 240 V, which has to produce the required current/voltage following in real time the reference provided by the JT-60SA MHD Controller. To minimize the current rating, these converters shall be sufficiently fast to avoid an excessive growth of the RWM. This requires a very high dynamic performance, largely beyond that of standard industrial applications. This paper firstly reports the latest results of the studies on the requirements of the RWM active control system. Then, the reference design of the power supply system is presented, including the ac/dc conversion stage, the fast converters and the control section. The advantages of the proposed scheme are discussed and the main electrical parameters are presented.

  13. Remote reference processing in MT survey using GPS clock; MT ho ni okeru GPS wo mochiita jikoku doki system

    Energy Technology Data Exchange (ETDEWEB)

    Yamane, K; Inoue, J; Takasugi, S [Geothermal Energy Research and Development Co. Ltd., Tokyo (Japan); Kosuge, S [DRICO Co. Ltd., Tokyo (Japan)

    1996-05-01

    A report is given about the application of a synchronizing system using clock signals from GPS satellites to a remote reference method which is a technique to reject noise from the MT method. This system uses the C/A code out of the L1 band waves from NAVSTAR/GPS satellites. The new system was operated in MT method-using investigations conducted at China Peninsula, Aichi Prefecture, and Izu Peninsula, Shizuoka Prefecture, with the reference points placed several 100km away in Iwate Prefecture on both occasions. It was found as the result that it is basically possible to catch signals from the GPS at any place, that the signals are accurate enough to be applied to time synchronization for the MT method, and that the signals assure a far remote reference method with a separation of several 100km between the sites involved. The referencing process at high frequencies whose feasibility had been doubted proved a success when highly correlated signals were exchanged between two stations over a distance of several 100km. 5 refs., 9 figs.

  14. Design and realization of the high-precision weighing systems as the gravimetric references in PTB's national water flow standard

    International Nuclear Information System (INIS)

    Engel, Rainer; Beyer, Karlheinz; Baade, Hans-Joachim

    2012-01-01

    PTB's ‘Hydrodynamic Test Field’, which represents a high-accuracy water flow calibration facility, serves as the national primary standard for liquid flow measurands. As the core reference device of this flow facility, a gravimetric standard has been incorporated, which comprises three special-design weighing systems: 300 kg, 3 tons and 30 tons. These gravimetric references were realized as a combination of a strain-gauge-based and an electromagnetic-force-compensation load-cell-based balance, each. Special emphasis had to be placed upon the dynamics design of the whole weighing system, due to the high measurement resolution and the dynamic behavior of the weighing systems, which are dynamically affected by mechanical vibrations caused by environmental impacts, flow machinery operation, flow noise in the pipework and induced wave motions in the weigh tanks. Taking into account all the above boundary conditions, the design work for the gravimetric reference resulted in a concrete foundation ‘rock’ of some 300 tons that rests on a number of vibration isolators. In addition to these passively operating vibration isolators, the vibration damping effect is enhanced by applying an electronic level regulation device. (paper)

  15. Changing quantum reference frames

    OpenAIRE

    Palmer, Matthew C.; Girelli, Florian; Bartlett, Stephen D.

    2013-01-01

    We consider the process of changing reference frames in the case where the reference frames are quantum systems. We find that, as part of this process, decoherence is necessarily induced on any quantum system described relative to these frames. We explore this process with examples involving reference frames for phase and orientation. Quantifying the effect of changing quantum reference frames serves as a first step in developing a relativity principle for theories in which all objects includ...

  16. Reference waste form, basalts, and ground water systems for waste interaction studies

    Energy Technology Data Exchange (ETDEWEB)

    Deju, R.A.; Ledgerwood, R.K.; Long, P.E.

    1978-09-01

    This report summarizes the type of waste form, basalt, and ground water compositions to be used in theoretical and experimental models of the geochemical environment to be simulated in studying a typical basalt repository. Waste forms to be used in the experiments include, and are limited to, glass, supercalcine, and spent unreprocessed fuel. Reference basalts selected for study include the Pomona member and the Umtanum Unit, Shwana Member, of the Columbia River Basalt Group. In addition, a sample of the Basalt International Geochemical Standard (BCR-1) will be used for cross-comparison purposes. The representative water to be used is of a sodium bicarbonate composition as determined from results of analyses of deep ground waters underlying the Hanford Site. 12 figures, 13 tables.

  17. Reference waste form, basalts, and ground water systems for waste interaction studies

    International Nuclear Information System (INIS)

    Deju, R.A.; Ledgerwood, R.K.; Long, P.E.

    1978-09-01

    This report summarizes the type of waste form, basalt, and ground water compositions to be used in theoretical and experimental models of the geochemical environment to be simulated in studying a typical basalt repository. Waste forms to be used in the experiments include, and are limited to, glass, supercalcine, and spent unreprocessed fuel. Reference basalts selected for study include the Pomona member and the Umtanum Unit, Shwana Member, of the Columbia River Basalt Group. In addition, a sample of the Basalt International Geochemical Standard (BCR-1) will be used for cross-comparison purposes. The representative water to be used is of a sodium bicarbonate composition as determined from results of analyses of deep ground waters underlying the Hanford Site. 12 figures, 13 tables

  18. Reference ranges for hematocrit and blood hemoglobin concentration during the neonatal period: data from a multihospital health care system.

    Science.gov (United States)

    Jopling, Jeffery; Henry, Erick; Wiedmeier, Susan E; Christensen, Robert D

    2009-02-01

    "Reference ranges" are developed when it is impossible or inappropriate to establish "normal ranges" by drawing blood on healthy normal volunteers. Reference ranges for the hematocrit and the blood hemoglobin concentration of newborn infants have previously been reported from relatively small sample sizes by using measurement methods that now are considered outmoded. We sought to develop reference ranges for hematocrit and hemoglobin during the neonatal period (28 days) by using very large sample sizes and modern hematology analyzers, accounting for gestational and postnatal age and gender. Data were assembled from a multihospital health care system after exclusion of patients with a high likelihood of an abnormal value and those who were receiving blood transfusions. During the interval from 22 to 40 weeks' gestation, the hematocrit and blood hemoglobin concentration increased approximately linearly. For every week advance in gestational age, the hematocrit increased by 0.64% and the hemoglobin concentration increased by 0.21 g/dL. No difference was seen on the basis of gender. During the 4-hour interval after birth, hematocrit/hemoglobin values of late preterm and term neonates (35-42 weeks' gestation) increased by 3.6% +/- 0.5% (mean +/- SD), those of neonates of 29 to 34 weeks' gestation remained unchanged, and those of hematocrit/hemoglobin occurred. The figures presented herein describe reference ranges for hematocrit and blood hemoglobin concentration during the neonatal period, accounting for gestational and postnatal age.

  19. Using reference trajectories to predicted uncertain systems: exemplified on a power plant

    DEFF Research Database (Denmark)

    Odgaard, Peter Fogh; Stoustrup, Jakob; Mataji, B.

    2007-01-01

    This paper presents a method for prediction of uncertain closed loop systems, where the uncertainties are depending on operating points. Such model uncertainties are often present when complicated non-linear systems are predicted. The method uses precomputed mean and variances of the prediction e...

  20. Automated Circulation Systems in Libraries Serving the Blind and Physically Handicapped: A Reference Guide for Planning.

    Science.gov (United States)

    Wanger, Judith; And Others

    Designed to facilitate communications in future automation projects between library and data processing personnel, especially those projects involving the use of automated systems in the service of disabled patrons, this guide identifies and describes a master set of major circulation system requirements and design considerations, and illustrates…

  1. Using Reference Architectures for Design and Evaluation of Web of Things Systems

    DEFF Research Database (Denmark)

    Chauhan, Muhammad Aufeef; Babar, Muhammad Ali

    2017-01-01

    Web of Things (WoT) provides abstraction that simplifies the creation of Internet of Things (IoT) systems. IoT systems are designed to support a number of ubiquitous devices and management subsystems. The devices and subsystems can be a part of safety critical op- erations as well as smart...

  2. EOS Reference Handbook 1999: A Guide to NASA's Earth Science Enterprise and the Earth Observing System

    Science.gov (United States)

    King, M. D. (Editor); Greenstone, R. (Editor)

    2000-01-01

    The content of this handbook includes Earth Science Enterprise; The Earth Observing System; EOS Data and Information System (EOSDIS); Data and Information Policy; Pathfinder Data Sets; Earth Science Information Partners and the Working Prototype-Federation; EOS Data Quality: Calibration and Validation; Education Programs; International Cooperation; Interagency Coordination; Mission Elements; EOS Instruments; EOS Interdisciplinary Science Investigations; and Points-of-Contact.

  3. Application of an electronic bulletin board, as a mechanism of coordination of actions in complex systems - reference model

    Directory of Open Access Journals (Sweden)

    Katarzyna Grzybowska

    2015-06-01

    Full Text Available Background: In her previous research, the author of this publication indicates that coordination is a dependent variable which has a great driving force and is a very unstable factor. This results in the fact that all of the actions connected with coordination have an impact on other factors of cooperation as well as the integration of the enterprises in the structures of a supply chain type structure. Material and methods:  The article has been divided into two basic parts. The first part regards the reference models in complex systems (supply chain systems. They can constitute a starting point for the modelling of target processes in the built supply chain structure. The second part presents template process models (Reference Models for selected action coordination mechanisms during enterprise cooperation. The aim of the article is the presentation the model an Electronic Bulletin Board (EBB, as a mechanism of coordination of actions in complex systems. Results: The article was prepared on the basis of literature from the researched area. The material was also prepared on the basis of interviews with practitioners. They have allowed for the preparation of template process models (Reference Models for selected action coordination methods in the supply chain. Conclusions: The result of the work is a prepared model as well as its description in the use of IDEF0. The presented model is a demonstrative model. The proposed reference model makes it possible to define the parameters of a selected mechanism of coordination of actions, and forms a basis for affecting the progression of the process through an analysis of values of identified parameters. The parameterization of elements constitutes the foundation for the monitoring of the process via 1 unambiguous identification of the object of monitoring and 2 analysis of different variants of the progression of the process.

  4. Standardized Semantic Markup for Reference Terminologies, Thesauri and Coding Systems: Benefits for distributed E-Health Applications.

    Science.gov (United States)

    Hoelzer, Simon; Schweiger, Ralf K; Liu, Raymond; Rudolf, Dirk; Rieger, Joerg; Dudeck, Joachim

    2005-01-01

    With the introduction of the ICD-10 as the standard for diagnosis, the development of an electronic representation of its complete content, inherent semantics and coding rules is necessary. Our concept refers to current efforts of the CEN/TC 251 to establish a European standard for hierarchical classification systems in healthcare. We have developed an electronic representation of the ICD-10 with the extensible Markup Language (XML) that facilitates the integration in current information systems or coding software taking into account different languages and versions. In this context, XML offers a complete framework of related technologies and standard tools for processing that helps to develop interoperable applications.

  5. Computer-assisted three-dimensional reconstruction of the corticospinal system as a reference for CT and MRI

    Energy Technology Data Exchange (ETDEWEB)

    Buhmann, C. [Department of Neuroanatomy, Hannover Medical School (Germany)]|[University Hospital Eppendorf, Hamburg (Germany); Kretschmann, H.J. [Department of Neuroanatomy, Hannover Medical School (Germany)

    1998-09-01

    We present a three-dimensional (3D) anatomical computer-graphics model of the corticospinal system acquired from equidistant serial anatomical slices of six intracranially-fixed human brains. This model is part of a neuroanatomical reference system (NeuRef) which enables 3D visualization of the brain and shows the relationship of its components such as anatomical structures, functional fibre tracts and arteries. Sections through the models can be matched with corresponding CT or MR images. This allows the probable localisation of corticospinal fibres on CT or MRI. (orig.) (orig.) With 18 figs., 3 tabs., 40 refs.

  6. Computer-assisted three-dimensional reconstruction of the corticospinal system as a reference for CT and MRI

    International Nuclear Information System (INIS)

    Buhmann, C.; Kretschmann, H.J.

    1998-01-01

    We present a three-dimensional (3D) anatomical computer-graphics model of the corticospinal system acquired from equidistant serial anatomical slices of six intracranially-fixed human brains. This model is part of a neuroanatomical reference system (NeuRef) which enables 3D visualization of the brain and shows the relationship of its components such as anatomical structures, functional fibre tracts and arteries. Sections through the models can be matched with corresponding CT or MR images. This allows the probable localisation of corticospinal fibres on CT or MRI. (orig.) (orig.)

  7. Validation of a motor activity system by a robotically controlled vehicle and using standard reference compounds.

    Science.gov (United States)

    Patterson, John P; Markgraf, Carrie G; Cirino, Maria; Bass, Alan S

    2005-01-01

    A series of experiments were undertaken to evaluate the accuracy, precision, specificity, and sensitivity of an automated, infrared photo beam-based open field motor activity system, the MotorMonitor v. 4.01, Hamilton-Kinder, LLC, for use in a good laboratory practices (GLP) Safety Pharmacology laboratory. This evaluation consisted of two phases: (1) system validation, employing known inputs using the EM-100 Controller Photo Beam Validation System, a robotically controlled vehicle representing a rodent and (2) biologic validation, employing groups of rats treated with the standard pharmacologic agents diazepam or D-amphetamine. The MotorMonitor's parameters that described the open-field activity of a subject were: basic movements, total distance, fine movements, x/y horizontal ambulations, rearing, and total rest time. These measurements were evaluated over a number of zones within each enclosure. System validation with the EM-100 Controller Photo Beam Validation System showed that all the parameters accurately and precisely measured what they were intended to measure, with the exception of fine movements and x/y ambulations. Biologic validation using the central nervous system depressant diazepam at 1, 2, or 5 mg/kg, i.p. produced the expected dose-dependent reduction in rat motor activity. In contrast, the central nervous system stimulant D-amphetamine produced the expected increases in rat motor activity at 0.1 and 1 mg/kg, i.p, demonstrating the specificity and sensitivity of the system. Taken together, these studies of the accuracy, precision, specificity, and sensitivity show the importance of both system and biologic validation in the evaluation of an automated open field motor activity system for use in a GLP compliant laboratory.

  8. Significant vestibular system impairment is common in a cohort of elderly patients referred for assessment of falls risk.

    Science.gov (United States)

    Jacobson, Gary P; McCaslin, Devin L; Grantham, Sarah L; Piker, Erin G

    2008-01-01

    Falls in elderly patients are associated with morbidity, mortality, and cost to the healthcare system. The development of falls risk assessment programs have represented a method of responding to what is known about injurious falls. The multidimensional assessments involve the comparison against normative data of a patient's performance on metrics known to influence the likelihood of future falls. The factors assessed usually include falls and medication history, measures of mentation, depression, orthostatic hypotension, simple or choice reaction time, gait stability, postural stability, and the integrity of the patient's vision, somesthetic, and vestibular senses. This investigation was conducted to measure the proportion of patients referred for falls risk assessment who have evidence of vestibular system impairment. Qualitative, retrospective review of data collected from 2003 to 2007. The cohort was 185 consecutive patients referred for multidimensional assessments of falls risk. Patients underwent quantitative assessments of peripheral and central vestibular system function consisting of electro- or videonystagmography (i.e., ENG/VNG), and sinusoidal harmonic acceleration testing. Results of these tests were compared to normative data. We found that 73% of the sample who underwent vestibular system assessment had quantitative evidence of either peripheral or central vestibular system impairment. Our results suggest that quantitative assessments of the vestibulo-ocular reflex should be conducted on patients who are evaluated for falls risk. These examinations should include at least caloric testing and, where available, rotational testing.

  9. New approach to isometric transformations in oblique local coordinate systems of reference

    Directory of Open Access Journals (Sweden)

    Stępień Grzegorz

    2017-12-01

    Full Text Available The research article describes a method of isometric transformation and determining an exterior orientation of a measurement instrument. The method is based on a designation of a “virtual” translation of two relative oblique orthogonal systems to a common, known in the both systems, point. The relative angle orientation of the systems does not change as each of the systems is moved along its axis. The next step is the designation of the three rotation angles (e.g. Tait-Bryan or Euler angles, transformation of the system convoluted at the calculated angles and moving the system to the initial position where the primary coordinate system was. This way eliminates movements of the systems from the calculations and makes it possible to calculate angles of mutual rotation angles of two orthogonal systems primarily involved in the movement. The research article covers laboratory calculations for simulated data. The accuracy of the results is 10-6 m (10-3 regarding the accuracy of the input data. This confi rmed the correctness of the assumed calculation method. In the following step the method was verifi ed under fi eld conditions, where the accuracy of the method raised to 0.003 m. The proposed method enabled to make the measurements with the oblique and uncentered instrument, e.g. total station instrument set over an unknown point. This is the reason why the method was named by the authors as Total Free Station - TFS. The method may be also used for isometric transformations for photogrammetric purposes.

  10. Prospective Randomized Controlled Study on the Efficacy of Multimedia Informed Consent for Patients Scheduled to Undergo Green-Light High-Performance System Photoselective Vaporization of the Prostate

    Directory of Open Access Journals (Sweden)

    Dong Yeub Ham

    2016-04-01

    Full Text Available Purpose: The aim of this study was to evaluate the efficacy of a multimedia informed consent (IC presentation on the understanding and satisfaction of patients who were scheduled to receive 120-W green-light high-performance system photoselective vaporization of the prostate (HPS-PVP. Materials and Methods: A multimedia IC (M-IC presentation for HPS-PVP was developed. Forty men with benign prostatic hyperplasia who were scheduled to undergo HPS-PVP were prospectively randomized to a conventional written IC group (W-IC group, n=20 or the M-IC group (n=20. The allocated IC was obtained by one certified urologist, followed by a 15-question test (maximum score, 15 to evaluate objective understanding, and questionnaires on subjective understanding (range, 0∼10 and satisfaction (range, 0∼10 using a visual analogue scale. Results: Demographic characteristics, including age and the highest level of education, did not significantly differ between the two groups. No significant differences were found in scores reflecting the objective understanding of HPS-PVP (9.9±2.3 vs. 10.6±2.8, p=0.332 or in subjective understanding scores (7.5±2.1 vs. 8.6±1.7, p=0.122; however, the M-IC group showed higher satisfaction scores than the W-IC group (7.4±1.7 vs. 8.4±1.5, p=0.033. After adjusting for age and educational level, the M-IC group still had significantly higher satisfaction scores. Conclusions: M-IC did not enhance the objective knowledge of patients regarding this surgical procedure. However, it improved the satisfaction of patients with the IC process itself.

  11. Examining the association of injury with the Functional Movement Screen and Landing Error Scoring System in military recruits undergoing 16 weeks of introductory fitness training.

    Science.gov (United States)

    Everard, Eoin; Lyons, Mark; Harrison, Andrew J

    2018-06-01

    To examine the association of injury with the Functional Movement Screen (FMS) and Landing Error Scoring System (LESS) in military recruits undergoing an intensive 16-week training block. Prospective cohort study. One hundred and thirty-two entry-level male soldiers (18-25years) were tested using the FMS and LESS. The participants underwent an intensive 16-week training program with injury data recorded daily. Chi-squared statistics were used to examine associations between injury risk and (1) poor LESS scores, (2) any score of 1 on the FMS and (3) composite FMS score of ≤14. A composite FMS score of ≤14 was not a significant predictor of injury. LESS scores of >5 and having a score of 1 on any FMS test were significantly associated with injury. LESS scores had greater relative risk, sensitivity and specificity (2.2 (95% CI=1.48-3.34); 71% and 87% respectively) than scores of 1 on the FMS (relative risk=1.32 (95% CI=1.0-1.7); sensitivity=50% and specificity=76%). There was no association between composite FMS score and injury but LESS scores and scores of 1 in the FMS test were significantly associated with injury in varying degrees. LESS scores had a much better association with injury than both any scores of 1 on the FMS and a combination of LESS scores and scores of 1 on the FMS. Furthermore, the LESS provides comparable information related to injury risk as other well-established markers associated with injury such as age, muscular strength and previous injury. Copyright © 2017. Published by Elsevier Ltd.

  12. Prospective Randomized Controlled Study on the Efficacy of Multimedia Informed Consent for Patients Scheduled to Undergo Green-Light High-Performance System Photoselective Vaporization of the Prostate

    Science.gov (United States)

    Ham, Dong Yeub; Choi, Woo Suk; Song, Sang Hoon; Ahn, Young-Joon; Park, Hyoung Keun; Kim, Hyeong Gon

    2016-01-01

    Purpose The aim of this study was to evaluate the efficacy of a multimedia informed consent (IC) presentation on the understanding and satisfaction of patients who were scheduled to receive 120-W green-light high-performance system photoselective vaporization of the prostate (HPS-PVP). Materials and Methods A multimedia IC (M-IC) presentation for HPS-PVP was developed. Forty men with benign prostatic hyperplasia who were scheduled to undergo HPS-PVP were prospectively randomized to a conventional written IC group (W-IC group, n=20) or the M-IC group (n=20). The allocated IC was obtained by one certified urologist, followed by a 15-question test (maximum score, 15) to evaluate objective understanding, and questionnaires on subjective understanding (range, 0~10) and satisfaction (range, 0~10) using a visual analogue scale. Results Demographic characteristics, including age and the highest level of education, did not significantly differ between the two groups. No significant differences were found in scores reflecting the objective understanding of HPS-PVP (9.9±2.3 vs. 10.6±2.8, p=0.332) or in subjective understanding scores (7.5±2.1 vs. 8.6±1.7, p=0.122); however, the M-IC group showed higher satisfaction scores than the W-IC group (7.4±1.7 vs. 8.4±1.5, p=0.033). After adjusting for age and educational level, the M-IC group still had significantly higher satisfaction scores. Conclusions M-IC did not enhance the objective knowledge of patients regarding this surgical procedure. However, it improved the satisfaction of patients with the IC process itself. PMID:27169129

  13. Oak Ridge TNS Program: reference design and program plan for a TNS ECH startup system

    International Nuclear Information System (INIS)

    Rosenfeld, R.

    1979-04-01

    The use of microwave radio frequency (rf) heating in The Next Step (TNS) is considered to be a viable approach to accomplishing reliable preionization while significantly lowering the peak power requirements and cost of the ohmic heating power supply system. Electron cyclotron heating (ECH) is a promising type of rf heating in which high power microwave energy is deposited into the plasma region. The proposed system is based on a configuration of five 200-kW gyroklystrons which will deliver 1 MW at 120 GHz to the plasma area for pulse periods of up to 6.0 sec. Completion of an operational system could be targeted for December 1989 at an estimated cost (in 1978 dollars) of $4 million. A discussion and description of a conceptual system are presented. Estimates of costs, schedules, and research and development (R and D) needs are included

  14. SeaVipers- Computer Vision and Inertial Position/Reference Sensor System (CVIPRSS)

    Science.gov (United States)

    2015-08-01

    power plants responsible for the genera- tion and distribution of electricity to the vessel, including cables and wiring. The Propulsion System...e.g. known criminals for a law- 17 enforcement application or past customers for commercial and marketing applications. When a specific face is...www.amazon.com/b?node=8037720011 [28] (2012) Burrito bomber: The worlds first airborne mexican food delivery system. [Online]. Available: http

  15. TELEPERM XS: I and C systems for safety application in NPP's - features, developments, references and feedback

    International Nuclear Information System (INIS)

    Prehler, Heinz Josef

    2007-01-01

    In the field of digital I and C AREVA NP is focused on concepts that on the one hand make allowance for development cycles getting shorter in the technology competition and on the other hand assure a long-term system support with the ability to deliver spare parts in the long run. The system platform TELEPERM XS, which was developed especially for safety I and C application of nuclear power plants, meets requirements effectively and thus provides a great benefit for the customer. The typical applications of TELEPERM XS are in the field of Reactor Protection and ESFAS functions (Engineered Safety Features Actuation System). High demands are defined for system reliability and availability, as well as for failure prevention and tolerance. The requirements of corresponding international codes and standards of nuclear installations are also implemented in the development and engineering processes of TELEPERM XS. The system platform is integrated into a sustainable program for service life management of electronic systems and equipment. Its ongoing future-oriented development ensures the long-term availability of hardware and software components for installed TELEPERM XS applications already installed in the plants. The further development of platform and components continues to be based on the robust, service-proven TELEPERM XS architecture, with the aim of minimizing the risks associated with equipment qualification and project licensing. A further development feature is the completion and extension of TELEPERM XS applications. This continuous innovation process, combined with maximized compatibility, makes TELEPERM XS unique, and provides the basis for a sustainable system with a service life guaranteed for the long term. Within the past 10 years, the majority of all comprehensive modernization projects worldwide were implemented or are contracted using TELEPERM XS. TELEPERM XS has been implemented in two new nuclear power plants and there are orders for four more

  16. Direct calibration of GC/MS systems using SRM (Standard Reference Material) gas cylinders. Project report, January 1984-August 1985

    International Nuclear Information System (INIS)

    Byrd, G.D.; Richie, K.L.; Sniegoski, L.T.; White, E.

    1985-10-01

    A cryogenic trapping system has been developed for use in calibrating GC/MS systems for the analysis of volatile organic compounds. This system provides for direct Standard Reference Material (SRM) traceability on data generated on gaseous samples. The cryogenic trap is a coil of stainless steel tubing immersed in a cryogen to trap and preconcentrate organic species present in a gaseous sample. The trap also contains a heated injection port for the addition of isotopically labeled compounds for use in isotope dilution measurements. The first part of this research is concerned with the development of IDMS as an independent method for the quantification of analytes in gaseous samples to be used as standards. Results are presented for the determination of bromobenzene in nitrogen at nominal concentrations of 1 and 25 ppb. In the second part of the research, a calibration curve method was developed for using these standards in auditing the performance of GC/MS systems

  17. Growth references

    NARCIS (Netherlands)

    Buuren, S. van

    2007-01-01

    A growth reference describes the variation of an anthropometric measurement within a group of individuals. A reference is a tool for grouping and analyzing data and provides a common basis for comparing populations.1 A well known type of reference is the age-conditional growth diagram. The

  18. Diagnosis of hepatic encephalopathy with magentic resonance imaging; With special reference to portal system encephalopathy

    Energy Technology Data Exchange (ETDEWEB)

    Inoue, Etsuo; Narumi, Yoshifumi; Kadota, Tsuyoshi; Fujita, Makoto; Kuriyama, Keiko; Kuroda, Chikazumi (Osaka Prefectural Center for Adult Diseases (Japan))

    1993-01-01

    Cranial magnetic resonance (MR) images were examined in 16 patients with liver cirrhosis. The findings of MR imaging were correlated with portal-systemic collateral vessel shown on angiograms. In 9 of 16 patients, basal ganglia was hyperintense compared with white matter on T1-weighted images. These 9 patients had portal-systemic collateral vessel 10 mm or more in diameter that was suppied by superior mesenteric vein (SMV), and 4 of the 9 patients had portal-systemic encephalopathy on angiograms. In the remaining 7 patients, no hyperintense lesions were seen in basal ganglia relative to white matter on T1-weighted images; angiography revealed that 2 patients had portal-systemic collateral vessel that was supplied by SMV but was 5 mm or less in diameter, 3 had bood supplies from splenic vein, and 2 had no collateral vessel. There was no change in signal intensity on T2-weighted images. In conclusion, a large portal-systemic collateral vessel supplied by SMV may be shown as a high intensity lesion in basal ganglia, thus making it possible to diagnose hepatic encephalopathy even if there was no psychoneurologic symptoms or signs. (N.K.).

  19. Active fault tolerant control of piecewise affine systems with reference tracking and input constraints

    DEFF Research Database (Denmark)

    Gholami, M.; Cocquempot, V.; Schiøler, H.

    2014-01-01

    An active fault tolerant control (AFTC) method is proposed for discrete-time piecewise affine (PWA) systems. Only actuator faults are considered. The AFTC framework contains a supervisory scheme, which selects a suitable controller in a set of controllers such that the stability and an acceptable...... performance of the faulty system are held. The design of the supervisory scheme is not considered here. The set of controllers is composed of a normal controller for the fault-free case, an active fault detection and isolation controller for isolation and identification of the faults, and a set of passive...... fault tolerant controllers (PFTCs) modules designed to be robust against a set of actuator faults. In this research, the piecewise nonlinear model is approximated by a PWA system. The PFTCs are state feedback laws. Each one is robust against a fixed set of actuator faults and is able to track...

  20. Systems analysis programs for hands-on integrated reliability evaluations (SAPHIRE) version 5.0, technical reference manual

    International Nuclear Information System (INIS)

    Russell, K.D.; Atwood, C.L.; Galyean, W.J.; Sattison, M.B.; Rasmuson, D.M.

    1994-07-01

    The Systems Analysis Programs for Hands-on Integrated Reliability Evaluations (SAPHIRE) refers to a set of several microcomputer programs that were developed to create and analyze probabilistic risk assessments (PRAs), primarily for nuclear power plants. This volume provides information on the principles used in the construction and operation of Version 5.0 of the Integrated Reliability and Risk Analysis System (IRRAS) and the System Analysis and Risk Assessment (SARA) system. It summarizes the fundamental mathematical concepts of sets and logic, fault trees, and probability. This volume then describes the algorithms that these programs use to construct a fault tree and to obtain the minimal cut sets. It gives the formulas used to obtain the probability of the top event from the minimal cut sets, and the formulas for probabilities that are appropriate under various assumptions concerning repairability and mission time. It defines the measures of basic event importance that these programs can calculate. This volume gives an overview of uncertainty analysis using simple Monte Carlo sampling or Latin Hypercube sampling, and states the algorithms used by these programs to generate random basic event probabilities from various distributions. Further references are given, and a detailed example of the reduction and quantification of a simple fault tree is provided in an appendix

  1. WASTES: Wastes system transportation and economic simulation: Version 2, Programmer's reference manual

    International Nuclear Information System (INIS)

    Buxbaum, M.E.; Shay, M.R.

    1986-11-01

    The WASTES Version II (WASTES II) Programmer's Reference Manual was written to document code development activities performed under the Monitored Retrievable Storage (MRS) Program at Pacific Northwest Laboratory (PNL). The manual will also serve as a valuable tool for programmers involved in maintenance of and updates to the WASTES II code. The intended audience for this manual are experienced FORTRAN programmers who have only a limited knowledge of nuclear reactor operation, the nuclear fuel cycle, or nuclear waste management practices. It is assumed that the readers of this manual have previously reviewed the WASTES II Users Guide published as PNL Report 5714. The WASTES II code is written in FORTRAN 77 as an extension to the SLAM commercial simulation package. The model is predominately a FORTRAN based model that makes extensive use of the SLAM file maintenance and time management routines. This manual documents the general manner in which the code is constructed and the interactions between SLAM and the WASTES subroutines. The functionality of each of the major WASTES subroutines is illustrated with ''block flow'' diagrams. The basic function of each of these subroutines, the algorithms used in them, and a discussion of items of particular note in the subroutine are reviewed in this manual. The items of note may include an assumption, a coding practice that particularly applies to a subroutine, or sections of the code that are particularly intricate or whose mastery may be difficult. The appendices to the manual provide extensive detail on the use of arrays, subroutines, included common blocks, parameters, variables, and files

  2. Development of skeletal system for mesh-type ICRP reference adult phantoms

    Science.gov (United States)

    Yeom, Yeon Soo; Wang, Zhao Jun; Tat Nguyen, Thang; Kim, Han Sung; Choi, Chansoo; Han, Min Cheol; Kim, Chan Hyeong; Lee, Jai Ki; Chung, Beom Sun; Zankl, Maria; Petoussi-Henss, Nina; Bolch, Wesley E.; Lee, Choonsik

    2016-10-01

    The reference adult computational phantoms of the international commission on radiological protection (ICRP) described in Publication 110 are voxel-type computational phantoms based on whole-body computed tomography (CT) images of adult male and female patients. The voxel resolutions of these phantoms are in the order of a few millimeters and smaller tissues such as the eye lens, the skin, and the walls of some organs cannot be properly defined in the phantoms, resulting in limitations in dose coefficient calculations for weakly penetrating radiations. In order to address the limitations of the ICRP-110 phantoms, an ICRP Task Group has been recently formulated and the voxel phantoms are now being converted to a high-quality mesh format. As a part of the conversion project, in the present study, the skeleton models, one of the most important and complex organs of the body, were constructed. The constructed skeleton models were then tested by calculating red bone marrow (RBM) and endosteum dose coefficients (DCs) for broad parallel beams of photons and electrons and comparing the calculated values with those of the original ICRP-110 phantoms. The results show that for the photon exposures, there is a generally good agreement in the DCs between the mesh-type phantoms and the original voxel-type ICRP-110 phantoms; that is, the dose discrepancies were less than 7% in all cases except for the 0.03 MeV cases, for which the maximum difference was 14%. On the other hand, for the electron exposures (⩽4 MeV), the DCs of the mesh-type phantoms deviate from those of the ICRP-110 phantoms by up to ~1600 times at 0.03 MeV, which is indeed due to the improvement of the skeletal anatomy of the developed skeleton mesh models.

  3. Open system LANs and their global interconnection electronics and communications reference series

    CERN Document Server

    Houldsworth, Jack; Caves, Keith; Mazda, FF

    2014-01-01

    Open System LANs and Their Global Interconnection focuses on the OSI layer 1 to 4 standards (the OSI bearer service) and also introduces TCP/IP and some of the proprietary PC Local Area Network (LAN) standards.The publication first provides an introduction to Local Area Networks (LANs) and Wide Area Networks (WANs), Open Systems Interconnection (OSI), and LAN standards. Discussions focus on MAC bridging, token bus, slotted ring, MAC constraints and design considerations, OSI functional standards, OSI model, value of the transport model, benefits and origins of OSI, and significance of the tran

  4. Bubble-vacuum system of accident localization of reference nuclear power plant with two WWER's

    International Nuclear Information System (INIS)

    Sykora, D.; Sykorova, I.

    1988-01-01

    Higher efficiency of the safety system for removing the consequences of project design accidents and higher radiation safety of a nuclear power plant with two WWER-440 units is the subject of Czechoslovak patent document 243961. The principle consists in interconnecting air chambers which are the end parts of safety systems for the two units. The air chamber is separated from the other parts of the safety system by double swing-check valves or closures. The connecting pipes of the two air chambers do not in any way reduce the reliability of the safety system thanks to their high technical safety and totally passive function. The benefits of the interconnection of the air chambers are given by the fact that it reduces maximum accident overpressure both in the air chambers and in the airtight zones. The reduction of the overpressure reduces the total leakage of radioactive substances and the radiation burden of the environment in case of a nuclear power plant accident. (Z.M.). 2 figs

  5. Agricultural intensification in Nepal, with particular reference to systems of rice intensification

    NARCIS (Netherlands)

    Uprety, Rajendra

    2016-01-01

    This thesis deals with agricultural intensification in Nepal. The initial focus of the study was the System of Rice Intensification (SRI), as introduced in Nepal from 2001. The multiple factors affecting SRI adoption, modification and dissemination together with the option to apply SRI in

  6. Design of a system of reference for positioning of patients in radiotherapy of breast cancer

    International Nuclear Information System (INIS)

    Nebot, P.; Reinado, D.; Salvador, R.; Gonzalez-Pena, R.; Dalmases, F.; Romero, C.; Rosello, J.; Diez, S.; Cibrian, R.

    2013-01-01

    The objective of this work is the design of a system of repositioning of the patient allowing to minimize errors both in everyday's the same placement as in the position held during the session, so that treatment would be intensified in the area to be treated, avoiding possible damage to other healthy areas. (Author)

  7. Moving Word Learning to a Novel Space: A Dynamic Systems View of Referent Selection and Retention

    Science.gov (United States)

    Samuelson, Larissa K.; Kucker, Sarah C.; Spencer, John P.

    2017-01-01

    Theories of cognitive development must address both the issue of how children bring their knowledge to bear on behavior in-the-moment, and how knowledge changes over time. We argue that seeking answers to these questions requires an appreciation of the dynamic nature of the developing system in its full, reciprocal complexity. We illustrate this…

  8. Integrated multilaboratory systems biology reveals differences in protein metabolism between two reference yeast strains

    DEFF Research Database (Denmark)

    Canelas, Andre B.; Harrison, Nicola; Fazio, Alessandro

    2010-01-01

    The field of systems biology is often held back by difficulties in obtaining comprehensive, high-quality, quantitative data sets. In this paper, we undertook an interlaboratory effort to generate such a data set for a very large number of cellular components in the yeast Saccharomyces cerevisiae,...

  9. Methods And Systems For Using Reference Images In Acoustic Image Processing

    Science.gov (United States)

    Moore, Thomas L.; Barter, Robert Henry

    2005-01-04

    A method and system of examining tissue are provided in which a field, including at least a portion of the tissue and one or more registration fiducials, is insonified. Scattered acoustic information, including both transmitted and reflected waves, is received from the field. A representation of the field, including both the tissue and the registration fiducials, is then derived from the received acoustic radiation.

  10. Variation in social systems within Chaetodon butterflyfishes, with special reference to pair bonding

    KAUST Repository

    Nowicki, Jessica P.

    2018-04-11

    For many animals, affiliative relationships such as pair bonds form the foundation of society and are highly adaptive. Animal systems amenable for comparatively studying pair bonding are important for identifying underlying biological mechanisms, but mostly exist in mammals. Better establishing fish systems will enable comparison of pair bonding mechanisms across taxonomically distant lineages that may reveal general underlying mechanistic principles. We examined the utility of wild butterflyfishes (f: Chaetodontidae; g: Chaetodon) for comparatively studying pair bonding. Using stochastic character mapping, we provide the first analysis of the evolutionary history of butterflyfish sociality, revealing that pairing is ancestral, with at least seven independent transitions to gregarious grouping and solitary behavior since the late Miocene. We then formally verified social systems in six sympatric and widespread species representing a clade with one ancestrally reconstructed transition from paired to solitary grouping at Lizard Island, Australia. In situ observations of the size, selective affiliation and aggression, fidelity, and sex composition of social groups confirmed that Chaetodon baronessa, C. lunulatus, and C. vagabundus are predominantly pair bonding, whereas C. rainfordi, C. plebeius, and C. trifascialis are predominantly solitary. Even in the predominantly pair bonding species, C. lunulatus, a proportion of adults (15%) are solitary. Importantly, inter- and intra-specific differences in social systems do not co-vary with other previously established attributes, including parental care. Hence, the proposed butterflyfish populations are promising for inter- and intra-species comparative analyses of pair bonding and its mechanistic underpinnings. Avenues for further developing the system are proposed, including determining whether the aforementioned utility of these species applies across their geographic disruptions.

  11. Immune complex modulation by plasma proteins. With special reference to the complement system and autoimmune diseases

    DEFF Research Database (Denmark)

    Baatrup, G

    1989-01-01

    The complement (C) system consists of two activation pathways, the classical and the alternative, which may both be activated by immune complexes (IC). C activation products become attached to the IC during activation leading to profound changes in the properties of the complexes. The common...... inflammation. 5) Tissue damage by activation and/or lysis of bystanding cells. 6) Modulation of B-cell proliferation and differentiation. Activation of the C system by IC is an essential normal component in the clearance of invading foreign material. However, in conditions with a persistent high concentration...... preformed, fluid phase IC (CMS assay). The CMS was found to be dependent upon the alternative pathway of C and facilitated by the classical. Further studies concerning the influence of C deficiencies or depletion of C factors, the concentration of divalent metallions, the temperature and the ionic strength...

  12. Reference ZrH reactor power system for NASA space station post-operational reentry analysis

    International Nuclear Information System (INIS)

    Elliott, R.D.

    1970-01-01

    The flight dynamic and heating of a spent ZrH reactor power system returning from orbit at the end of its useful life are analyzed. The results of this analysis indicate that the reactor with a large portion of the lithium shield still surrounding it will impact the earth at a velocity of from 660 to 820 ft/sec, depending upon whether it tumbles or becomes stabilized during the latter part of its trajectory. (U.S.)

  13. A Reference Architecture for Electronic Business-to-Business Collaboration Setup and Enactment Systems

    OpenAIRE

    Norta, A.; Grefen, P.; Angelov, S.; Kutvonen, L.

    2010-01-01

    The question what a business-to-business (B2B) collaboration setup and enactment application-system should look like remains open. An important element of such collaboration constitutes the inter-organizational disclosure of business-process details so that the opposing parties may protect their business secrets. For that purpose, eSourcing [37] has been developed as a general businessprocess collaboration concept in the framework of the EU research project Cross- Work. The eSourcing characte...

  14. Critical care providers refer to information tools less during communication tasks after a critical care clinical information system introduction.

    Science.gov (United States)

    Ballermann, Mark; Shaw, Nicola T; Mayes, Damon C; Gibney, R T Noel

    2011-01-01

    Electronic documentation methods may assist critical care providers with information management tasks in Intensive Care Units (ICUs). We conducted a quasi-experimental observational study to investigate patterns of information tool use by ICU physicians, nurses, and respiratory therapists during verbal communication tasks. Critical care providers used tools less at 3 months after the CCIS introduction. At 12 months, care providers referred to paper and permanent records, especially during shift changes. The results suggest potential areas of improvement for clinical information systems in assisting critical care providers in ensuring informational continuity around their patients.

  15. [Establishing a clinical information system for surgical ophthalmology and orthopedics specialties with reference to GSG '93].

    Science.gov (United States)

    Dick, B; Basad, E

    1996-04-01

    As a result of new health care guidelines (Gesundheitsstrukturgesetz) and the federal hospital and nursing ordinance, there has been a large increase in the documentation required for diagnoses (ICD-9) and service ("Operationenschlüssel nach section 301 SGB V" = ICPM), all of which is done in the form of a numeric code. The method of coding diagnoses is supposed to make possible data entry and statistical evaluation of plausibility controls, as well as conspicuous and random testing of economic feasibility. Our data processing system is designed to assist in the planning and organization of clinical activities, while at the same time making documentation in accordance with health care guidelines easier and providing scientific documentation and evaluation. The application MedAccess was developed by clinicians on the basis of a relational client-server database. The application has been in use since June 1992 and has been further developed during operation according to the requirements and wishes of clinic and administrative staff. In cooperation with the Institute for Medical Information Technology, a computer interface with the patient check-in system was created, making possible the importing of patient data. The application is continuously updated according to the current needs of the clinic and administration. The primary functions of MedAccess include managing patient data, planning of in-patient admissions, surgical planning, organization, documentation (surgery book, reports with follow-up treatment records), administration of the tissue bank, clinic communications, clinic work processing, and management of the staff duty roster. Clinical data are entered into a computer and processed on site, and the user is assisted by practical applications which do not require special knowledge of data processing or encoding systems. The data is entered only once, but can be further used for other purposes, such as evaluations or selective transfer, for example, to

  16. A Wireless Swing Angle Measurement Scheme Using Attitude Heading Reference System Sensing Units Based on Microelectromechanical Devices

    Directory of Open Access Journals (Sweden)

    Bingtuan Gao

    2014-11-01

    Full Text Available Feasible real-time swing angle measurement is significant to improve the efficiency and safety of industrial crane systems. This paper presents a wireless microelectromechanical system (MEMS-based swing angle measurement system. The system consists of two attitude heading reference system (AHRS sensing units with a wireless communication function, which are mounted on the hook (or payload and the jib (or base of the crane, respectively. With a combination of a three-axis accelerometer, a three-axis gyroscope and a three-axis magnetometer, the standard extended Kalman filter (EKF is used to estimate the desired orientation of the payload and the base. Wireless ZigBee communication is employed to transmit the orientation of the payload to the sensing unit mounted on the base, which measures the orientation of the base. Because several physical parameters from the payload to the base can be acquired from the original crane control system, the swing angles of the payload can be calculated based on the two measured orientation parameters together with the known physical parameters. Experiments were performed to show the feasibility and effectiveness of the proposed swing angle measurement system.

  17. An artificial neural network system to identify alleles in reference electropherograms.

    Science.gov (United States)

    Taylor, Duncan; Harrison, Ash; Powers, David

    2017-09-01

    Electropherograms are produced in great numbers in forensic DNA laboratories as part of everyday criminal casework. Before the results of these electropherograms can be used they must be scrutinised by analysts to determine what the identified data tells them about the underlying DNA sequences and what is purely an artefact of the DNA profiling process. This process of interpreting the electropherograms can be time consuming and is prone to subjective differences between analysts. Recently it was demonstrated that artificial neural networks could be used to classify information within an electropherogram as allelic (i.e. representative of a DNA fragment present in the DNA extract) or as one of several different categories of artefactual fluorescence that arise as a result of generating an electropherogram. We extend that work here to demonstrate a series of algorithms and artificial neural networks that can be used to identify peaks on an electropherogram and classify them. We demonstrate the functioning of the system on several profiles and compare the results to a leading commercial DNA profile reading system. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Reference Manual for the System Advisor Model's Wind Power Performance Model

    Energy Technology Data Exchange (ETDEWEB)

    Freeman, J.; Jorgenson, J.; Gilman, P.; Ferguson, T.

    2014-08-01

    This manual describes the National Renewable Energy Laboratory's System Advisor Model (SAM) wind power performance model. The model calculates the hourly electrical output of a single wind turbine or of a wind farm. The wind power performance model requires information about the wind resource, wind turbine specifications, wind farm layout (if applicable), and costs. In SAM, the performance model can be coupled to one of the financial models to calculate economic metrics for residential, commercial, or utility-scale wind projects. This manual describes the algorithms used by the wind power performance model, which is available in the SAM user interface and as part of the SAM Simulation Core (SSC) library, and is intended to supplement the user documentation that comes with the software.

  19. Risks associated with volcanic ash fallout from Mt.Etna with reference to industrial filtration systems

    International Nuclear Information System (INIS)

    Milazzo, Maria Francesca; Ancione, Giuseppa; Salzano, Ernesto; Maschio, Giuseppe

    2013-01-01

    The recent eruption of the Icelandic volcano has focused the worldwide attention on volcanic ash effects for the population, road, rail and air traffic and production activities. This paper aims to study of technological (industrial) accidental scenarios triggered by ash fallout and, more specifically, to define and quantify the potential damage on filtration systems. Malfunctions due to the filter clogging and service interruptions caused by the rupture of the filtering surface have been analysed in order to define the vulnerability of the equipment to such damages. Results are given in terms of threshold values of deposit on the filtering surface and exceedance probability curves of ash concentrations and the duration of the ash emission. This data can be easily implemented in the standard risk assessment with the aim to include the estimation of Natural-Technological (Na-Tech) hazards

  20. Prescribing during pregnancy and lactation with reference to the Swedish classification system

    DEFF Research Database (Denmark)

    Olesen, Charlotte; Sørensen, Henrik Toft; Berg, Lolkje de Jong-van den

    1999-01-01

    retail pharmacies, made it possible to identify prescriptions by individual use. All 34,334 prescriptions were set against the Swedish classification of risk of drug use in pregnancy and lactation. RESULTS: During pregnancy, safe (group A), potentially harmful (group B3, C, and D), and non...... and II), drugs with possible harmful neonatal effects (group III), and non-classifiable drugs accounted for 43.5%, 4.8%, and 35.8% of the prescriptions, respectively. CONCLUSION: According to the Swedish classification system, we found that during pregnancy and lactation a high proportion of Danish women...... were exposed to one or more drugs in high risk groups; furthermore, knowledge regarding their safety for the fetus and neonate was limited for a large proportion of the prescriptions. Current evidence about long-term effects of prenatal exposure stresses the need for long-term follow-up of health...

  1. [Reference citation].

    Science.gov (United States)

    Brkić, Silvija

    2013-01-01

    Scientific and professional papers represent the information basis for scientific research and professional work. References important for the paper should be cited within the text, and listed at the end of the paper. This paper deals with different styles of reference citation. Special emphasis was placed on the Vancouver Style for reference citation in biomedical journals established by the International Committee of Medical Journal Editors. It includes original samples for citing various types of articles, both printed and electronic, as well as recommendations related to reference citation in accordance with the methodology and ethics of scientific research and guidelines for preparing manuscripts for publication.

  2. Reproducibility of the sella turcica landmark in three dimensions using a sella turcica-specific reference system

    International Nuclear Information System (INIS)

    Pittayapat, Pisha; Jacobs, Reinhilde; Odri, Guillaume A.; De Faria Vasconcelos, Karla; Willems, Guy; Olszewski, Raphael

    2015-01-01

    This study was performed to assess the reproducibility of identifying the sella turcica landmark in a three-dimensional (3D) model by using a new sella-specific landmark reference system. Thirty-two cone-beam computed tomographic scans (3D Accuitomo 170, J. Morita, Kyoto, Japan) were retrospectively collected. The 3D data were exported into the Digital Imaging and Communications in Medicine standard and then imported into the Maxilim software (Medicim NV, Sint-Niklaas, Belgium) to create 3D surface models. Five observers identified four osseous landmarks in order to create the reference frame and then identified two sella landmarks. The x, y, and z coordinates of each landmark were exported. The observations were repeated after four weeks. Statistical analysis was performed using the multiple paired t-test with Bonferroni correction (intraobserver precision: p<0.005, interobserver precision: p<0.0011). The intraobserver mean precision of all landmarks was <1 mm. Significant differences were found when comparing the intraobserver precision of each observer (p<0.005). For the sella landmarks, the intraobserver mean precision ranged from 0.43±0.34 mm to 0.51±0.46 mm. The intraobserver reproducibility was generally good. The overall interobserver mean precision was <1 mm. Significant differences between each pair of observers for all anatomical landmarks were found (p<0.0011). The interobserver reproducibility of sella landmarks was good, with >50% precision in locating the landmark within 1 mm. A newly developed reference system offers high precision and reproducibility for sella turcica identification in a 3D model without being based on two-dimensional images derived from 3D data.

  3. Reproducibility of the sella turcica landmark in three dimensions using a sella turcica-specific reference system

    Energy Technology Data Exchange (ETDEWEB)

    Pittayapat, Pisha; Jacobs, Reinhilde [University Hospitals Leuven, University of Leuven, Leuven (Belgium); Odri, Guillaume A. [Service de Chirurgie Orthopedique et Traumatologique, Centre Hospitalier Regional d' Orleans, Orleans Cedex2 (France); De Faria Vasconcelos, Karla [Dept. of Oral Diagnosis, Division of Oral Radiology, Piracicaba Dental School, University of Campinas, Sao Paulo (Brazil); Willems, Guy [Dept. of Oral Health Sciences, Orthodontics, KU Leuven and Dentistry, University Hospitals Leuven, University of Leuven, Leuven (Belgium); Olszewski, Raphael [Dept. of Oral and Maxillofacial Surgery, Cliniques Universitaires Saint Luc, Universite Catholique de Louvain, Brussels (Belgium)

    2015-03-15

    This study was performed to assess the reproducibility of identifying the sella turcica landmark in a three-dimensional (3D) model by using a new sella-specific landmark reference system. Thirty-two cone-beam computed tomographic scans (3D Accuitomo 170, J. Morita, Kyoto, Japan) were retrospectively collected. The 3D data were exported into the Digital Imaging and Communications in Medicine standard and then imported into the Maxilim software (Medicim NV, Sint-Niklaas, Belgium) to create 3D surface models. Five observers identified four osseous landmarks in order to create the reference frame and then identified two sella landmarks. The x, y, and z coordinates of each landmark were exported. The observations were repeated after four weeks. Statistical analysis was performed using the multiple paired t-test with Bonferroni correction (intraobserver precision: p<0.005, interobserver precision: p<0.0011). The intraobserver mean precision of all landmarks was <1 mm. Significant differences were found when comparing the intraobserver precision of each observer (p<0.005). For the sella landmarks, the intraobserver mean precision ranged from 0.43±0.34 mm to 0.51±0.46 mm. The intraobserver reproducibility was generally good. The overall interobserver mean precision was <1 mm. Significant differences between each pair of observers for all anatomical landmarks were found (p<0.0011). The interobserver reproducibility of sella landmarks was good, with >50% precision in locating the landmark within 1 mm. A newly developed reference system offers high precision and reproducibility for sella turcica identification in a 3D model without being based on two-dimensional images derived from 3D data.

  4. NEURO-SYSTEM OF AIMING AND STABILIZING WITH A REGULATOR ON THE BASIS OF STANDARD MODEL MODEL REFERENCE CONTROLLER

    Directory of Open Access Journals (Sweden)

    B.I. Kuznetsov

    2015-08-01

    Full Text Available The aim of this work is the synthesis of neural network aiming and stabilization system for the special equipment of moving objects with neuro-controller on the basis of standard model and performance comparison of the neural network system with the neural network predictive control. Build a block diagram of the neural network aiming and stabilization system, based on the subject control principle with PD-regulator in the position loop and with neuro-controller on the basis of standard model in the in the velocity loop. The neuro-controller on the basis of standard model Model Reference Controller is synthesized in the MATLAB Neural Network Toolbox and system simulation is performed. The studies show that the transient state variables of the system are oscillatory. Therefore, the neuro-controller with the prediction NN Predictive Controller should be used for aiming and stabilizing system to provide high dynamic characteristics achieved at the cost of higher complexity and computational cost.

  5. Aquatic systems in and adjacent to Agulhas National Park with particular reference to the fish fauna

    Directory of Open Access Journals (Sweden)

    I.A. Russell

    2006-12-01

    Full Text Available The study aimed to determine the distribution and relative abundance of freshwater fishes in and adjacent to Agulhas National Park. Fourteen fish species were collected during surveys carried out in the Heuningnes and Ratel river systems and a variety of endorheic pans from 2003 to 2005. Seven of the species are marine fishes tolerant of low salinity (Mugil cephalus, Liza richardsonii, Monodactylus falciformis, Caffrogobius gilchristi, Rhabdosargus holubi, Solea bleekeri, Gilchristella aestuaria with the remaining seven species being primary freshwater fishes. Three are indigenous, including Pseudobarbus burchelli, Sandelia capensis, and Galaxias zebratus of which two morphological forms were recorded within Agulhas National Park. The remaining four species are invasive aliens (Cyprinus carpio, Lepomis macrochirus, Micropterus salmoides, Micropterus punctulatus. Classification using physico-chemical variables indicated four major wetland groups, with fishes occurring predominantly in the group comprising palustrine, lacustrine and riverine wetlands, and in one instance in a brackish endorheic pan. Management actions which should facilitate conservation of indigenous fishes in the Agulhas region are suggested.

  6. PTPN22 gene polymorphisms in autoimmune diseases with special reference to systemic lupus erythematosus disease susceptibility

    Directory of Open Access Journals (Sweden)

    Pradhan V

    2010-01-01

    Full Text Available Systemic lupus erythematosus (SLE is a prototype autoimmune disease. SLE is a result of one or more immune mechanisms, like autoantibody production, complement activation, multiple inflammation and immune complex deposition leading to organ tissue damage. SLE affected patients are susceptible to common and opportunistic infections. There are several reports suggesting that Mycobacterium tuberculosis infection precipitates SLE in patients from endemic areas. Genetic factors and environmental factors also play an important role in the overall susceptibility to SLE pathophysiology. Recently, protein tyrosine phosphatase, non-receptor type 22 (PTPN22 gene, has been found to be associated with several autoimmune diseases like SLE, Grave′s disease and Hashimoto thyroiditis. The missense R620W polymorphism, rs 2476601, in PTPN22 gene at the nucleotide 1858 in codon 620 (620Arg > Trp has been associated with autoimmune diseases. The PTPN22 locus is also found to be responsible for development of pulmonary tuberculosis in certain populations. The PTPN22 1858C/T gene locus will be ideal to look for SLE susceptibility to tuberculosis in the Indian population. In this review, we focus on human PTPN22 gene structure and function as well as the association of PTPN22 gene polymorphisms with SLE susceptibility

  7. [Psychiatric Disorders in Pediatric Patients With Systemic Lupus Erythematosus in a Reference Hospital].

    Science.gov (United States)

    Zuñiga Zambrano, Yenny Carolina; Vásquez, Rafael

    2014-01-01

    To describe the psychiatric manifestations in pediatric patients with systemic erythematous lupus seen in the Fundación Hospital de la Misericordia. Observational descriptive study. Medical charts and test results of inpatients and outpatients between 2007 and2013 were reviewed; 39 patients were selected. SPSS 19 was used for statistical analysis. Statistical significance was considered with P=.05. Mean age was 13.7 (2.33), with 78.9% female. The most frequent psychiatric manifestation was anxiety (52.6%), followed by adjustment disorder and depression (36.8% each one), psychosis (10%), conversion disorder (7.9%), and obsessive compulsive disorder (5.3%). The mean SLICC score was 2.76 (2.8), and the mean SLEDAI score was 20.81 (20.82). Antinuclear antibodies were positive in 81.25%. Neuropsychiatric lupus was diagnosed in 65.8% of patients; seizures were observed in 23.7%, headache in 36.8%, stroke in 13.2%, vasculitis, chorea 5.3%, and meningitis 5.3% of patients. The mean time from lupus diagnosis was 20.47 (22.2) months, with the shortest period for adjustment disorder and the longest period in patients with conversion disorder (pseudo-seizures) being 15 months and 31 months, respectively. The highest SLEDAI score was in patients with psychosis (35.5 [16.21] vs 19.08 [13.72]; P=.032), and also the highest disease damage (SLICC, 4.25 [4.03] vs 2.58 [2.67]; P=.27) in comparison with the other manifestations. The most frequent psychiatric manifestations were anxiety, depression, and adjustment disorder, with a higher frequency than other studies, and with lupus activity principally in patients with psychosis. Copyright © 2013 Asociación Colombiana de Psiquiatría. Publicado por Elsevier España. All rights reserved.

  8. Importance of quality aspects of GP care among ethnic minorities: role of cultural attitudes, language and healthcare system of reference.

    Science.gov (United States)

    Lamkaddem, Majda; Spreeuwenberg, Peter M; Devillé, Walter L; Foets, Marleen M; Groenewegen, Peter P

    2012-02-01

    This study examines the mechanisms responsible for ethnic differences in perceived quality of care in The Netherlands. The specific role of cultural attitudes, language proficiency, and the health system in the country of origin was examined, taking socio-demographic characteristics into account. Interview data of 1339 respondents of Moroccan, Turkish, Surinamese and Antillean origin were combined with interview data of Dutch respondents (n = 405) and of Western immigrants (n = 102) in The Netherlands and of a random sample of Dutch privately or publicly insured persons (n = 9675). Data collection took place within the Second Dutch National Survey of General Practice (DNSGP-2, 2001). Items from the QUality Of care Through the patient's Eyes (QUOTE) questionnaire were used to measure expectations, as well as items from the QUOTE-Mi (adapted version for migrant groups). Items on normative orientations were used to measure cultural attitudes. In contrast to our hypothesis, respondents with more egalitarian/modern attitudes attached less importance to quality aspects related to access and quality. Tests on the role of the health system of reference were generally conclusive, showing that respondents accustomed to (parts of) another system have different expectations regarding several aspects of general practitioner healthcare quality, e.g. access to specialist care. Besides socio-demographic characteristics, culture influences patients' expectations regarding general practitioner care quality. However, the role of culture can be more clearly ascribed to the characteristics of the health system which is held as the reference than to the general attitudes on normative orientations.

  9. On the system of provision of ojsc "MMC 'Norilsk Nickel'" with interstate and State certified reference materials for quality control of cobalt, nickel, copper and promproducts

    Directory of Open Access Journals (Sweden)

    T. V. Shabelnikova

    2014-01-01

    Full Text Available In order to manage the quality of OJSC "MMC "Norilsk Nickel" products the Centre of Certified Reference Material Development has developed and is currently successfully implementing a system of operations provision with interstate and state certified reference materials of nickel, cobalt and copper composition. The system wholly corresponds to modern metrological requirements. The Centre of Reference Materials Development, fulfilling leading function in the field of state certified reference material production and supply to the Company's operations, aims its activity both at the development of new types of certified reference materials in the form of metals and at widening the range of synthetic oxide certified reference materials. Developed for the first time, metallic state certified reference materials of nickel, cobalt composition with certified mass fractions of oxygen, hydrogen, nitrogen, sulfur and carbon were put into practice of the Company's analytical services work. Certified reference material use provides the possibility to take into account requirements of some consumers to the quality of nickel and produce by OJSC "MMC "Norilsk Nickel" and also helps to raise competitive ability of the products on the world metals market. Over recent years the Centre fulfilled the work on the development, certification in established order, approval and entering into the State Register twenty five types of state certified reference materials. Certified reference materials are intended for fulfillment of the analysis of chemical composition of nickel, cobalt and copper in terms of their conformity with both national and international standards.

  10. Reference Assessment

    Science.gov (United States)

    Bivens-Tatum, Wayne

    2006-01-01

    This article presents interesting articles that explore several different areas of reference assessment, including practical case studies and theoretical articles that address a range of issues such as librarian behavior, patron satisfaction, virtual reference, or evaluation design. They include: (1) "Evaluating the Quality of a Chat Service"…

  11. 1-GWh diurnal load-leveling superconducting magnetic energy storage system reference design. Appendix F. 1-GWh electrical system design

    International Nuclear Information System (INIS)

    Boenig, H.J.

    1979-09-01

    Two circuit configurations for reducing the installed converter power and cost of high-power converter systems that operate in a constant-power mode over a wide current and voltage range are suggested and analyzed

  12. An analytic-numerical method for the construction of the reference law of operation for a class of mechanical controlled systems

    Science.gov (United States)

    Mizhidon, A. D.; Mizhidon, K. A.

    2017-04-01

    An analytic-numerical method for the construction of a reference law of operation for a class of dynamic systems describing vibrations in controlled mechanical systems is proposed. By the reference law of operation of a system, we mean a law of the system motion that satisfies all the requirements for the quality and design features of the system under permanent external disturbances. As disturbances, we consider polyharmonic functions with known amplitudes and frequencies of the harmonics but unknown initial phases. For constructing the reference law of motion, an auxiliary optimal control problem is solved in which the cost function depends on a weighting coefficient. The choice of the weighting coefficient ensures the design of the reference law. Theoretical foundations of the proposed method are given.

  13. Recent references

    International Nuclear Information System (INIS)

    Ramavataram, S.

    1991-01-01

    In support of a continuing program of systematic evaluation of nuclear structure data, the National Nuclear Data Center maintains a complete computer file of references to the nuclear physics literature. Each reference is tagged by a keyword string, which indicates the kinds of data contained in the article. This master file of Nuclear Structure References (NSR) contains complete keyword indexes to literature published since 1969, with partial indexing of older references. Any reader who finds errors in the keyword descriptions is urged to report them to the National Nuclear Data Center so that the master NSR file can be corrected. In 1966, the first collection of Recent References was published as a separate issue of Nuclear Data Sheets. Every four months since 1970, a similar indexed bibliography to new nuclear experiments has been prepared from additions to the NSR file and published. Beginning in 1978, Recent References was cumulated annually, with the third issue completely superseding the two issues previously published during a given year. Due to publication policy changes, cumulation of Recent Reference was discontinued in 1986. The volume and issue number of all the cumulative issues published to date are given. NNDC will continue to respond to individual requests for special bibliographies on nuclear physics topics, in addition to those easily obtained from Recent References. If the required information is available from the keyword string, a reference list can be prepared automatically from the computer files. This service can be provided on request, in exchange for the timely communication of new nuclear physics results (e.g., preprints). A current copy of the NSR file may also be obtained in a standard format on magnetic tape from NNDC. Requests for special searches of the NSR file may also be directed to the National Nuclear Data Center

  14. Clinical Application of Different Surgical Navigation Systems in Complex Craniomaxillofacial Surgery: The Use of Multisurface 3-Dimensional Images and a 2-Plane Reference System.

    Science.gov (United States)

    Liu, Tom J; Ko, An-Ta; Tang, Yueh-Bih; Lai, Hong-Shiee; Chien, Hsiung-Fei; Hsieh, Thomas Mon-Hsian

    2016-04-01

    Intraoperative navigation is a tool that provides surgeons with real-time guidance based on patients' preoperative imaging studies. The application of intraoperative navigation to neurosurgery and otolaryngology has been well documented; however, only isolated reports have analyzed its potential in the field of craniomaxillofacial surgery. From November 2010 to July 2014, 15 patients were operated on for complex craniomaxillofacial surgery with assistance by 3 different navigation systems, which used either infrared or electromagnetic technologies. We imported fine-cut (0.625-mm) computed tomographic scan images of the patients to the navigation systems whose software processed them into multisurface 3-dimentional models used as guiding material for the surgical navigation. We also developed a simple "2-plane reference system" to ensure that the final results were symmetric to the normal half of the face. Appearance outcome was evaluated by questionnaire. Of these 15 cases, 3 cases were performed with infrared-based navigation, and the remaining 12 cases were accomplished by electromagnetic technology. Most of these cases resulted in satisfactory outcomes after tumor resection, posttraumatic reconstruction, and postablative reconstruction. Navigation systems offer highly valuable intraoperative assistance in complex craniomaxillofacial surgery. Not only can these systems pinpoint deep-seated lesions as neurosurgeons or otolaryngologists do, but they can also use a simple 2-plane reference system for accurate bone alignment. Moreover, advancements in multisurface 3-D models provide us more reliable intuitive image guidance. The application of electromagnetic technology, with its smaller reference obviation of the line-of-sight problem, makes the manipulation of craniomaxillofacial surgery more comfortable.

  15. Collaborative reference management system

    CSIR Research Space (South Africa)

    Le Roux, WH

    2009-05-01

    Full Text Available Developers free Yes, GPL License All BibTeX, BiblX, MODS XML, RIS BibTeX, Compac, ISI, BiblX, RIS, RefWorks RefWorks US$100 per year No All, web- based BibTeX and RIS BibTeX (partially), CSA, BiblX, ISI, Medline, Ovid, PubMed, RIS, Sci... fully to ensure your views are not misconstrued • Consider the five “Cs” of effective communication – Clarity, Completeness, Conciseness, Correctness and concreteness. According to Spence et al’s (2005) research, communication consists out of fifty...

  16. Dose reference levels in Spanish intraoral dental radiology: stabilisation of the incorporation of digital systems in dental clinical practices

    International Nuclear Information System (INIS)

    Alcaraz, M.; Velasco, F.; Olivares, A.; Velasco, E.; Canteras, M.

    2016-01-01

    A total of 34 044 official quality assurance reports in dental radiodiagnostic surgery from 16 regions of Spain, compiled from 2002 to 2014, were studied in order to determine the progress of diagnostic reference levels (DRLs) for obtaining diagnostic images under normal conditions for clinical practice in Spanish dental clinics. A DRL of 2.8 mGy was set in 2014, which represents a 41.7 % decrease compared with that of 2002 (4.8 mGy). Over the same time period, the mean dose fell by 55.2 %. However, over the last 3 y, the stabilisation of the mean dose administered to patients has been observed with only a 6.7 % reduction in DRLs, which corresponds to the stabilisation of dental radiodiagnostic surgery on replacing the use of radiographic film with digital imaging systems. (authors)

  17. Implementation of a model reference adaptive control system using neural network to control a fast breeder reactor evaporator

    International Nuclear Information System (INIS)

    Ugolini, D.; Yoshikawa, S.; Endou, A.

    1994-01-01

    Artificial intelligence is foreseen as the base for new control systems aimed to replace traditional controllers and to assist and eventually advise plant operators. This paper discusses the development of an indirect model reference adaptive control (MRAC) system, using the artificial neural network (ANN) technique, and its implementation to control the outlet steam temperature of a sodium to water evaporator. The ANN technique is applied in the identification and in the control process of the indirect MRAC system. The emphasis is placed on demonstrating the efficacy of the indirect MRAC system in controlling the outlet steam temperature of the evaporator, and on showing the important function covered by the ANN technique. An important characteristic of this control system is that it relays only on some selected input variables and output variables of the evaporator model. These are the variables that can be actually measured or calculated in a real environment. The results obtained applying the indirect MRAC system to control the evaporator model are quite remarkable. The outlet temperature of the steam is almost perfectly kept close to its desired set point, when the evaporator is forced to depart from steady state conditions, either due to the variation of some input variables or due to the alteration of some of its internal parameters. The results also show the importance of the role played by the ANN technique in the overall control action. The connecting weights of the ANN nodes self adjust to follow the modifications which may occur in the characteristic of the evaporator model during a transient. The efficiency and the accuracy of the control action highly depends on the on-line identification process of the ANN, which is responsible for upgrading the connecting weights of the ANN nodes. (J.P.N.)

  18. Development of a Reference System for the determination of the personal dose equivalent and the constancy of X- Ray beams

    International Nuclear Information System (INIS)

    Vivolo, Vitor

    2006-01-01

    A reference system for the determination of the personal dose equivalent, Hp (10), and a quality control program of X-ray equipment used In radioprotection require the periodic verification of the X-ray beams constancy. In this work, two parallel-plate ionization chambers were developed with inner electrodes of different materials, and inserted into PMMA slab phantoms. One ionization chamber was developed with inner carbon electrodes and the other with inner aluminium electrodes. The two ionization chambers can be used as a Tandem system. The different energy response of the two ionization chambers allowed the development of the Tandem system that is very useful for the checking of the constancy of beam qualities. Standard intermediary energy X-ray beams (from 48 keV to 118 keV), radioprotection level, were established through the development of a dosimetric methodology and the analysis of their physical parameters. The ionization chambers were studied in relation to their operational characteristics, and they were calibrated in X-ray beams (radioprotection, diagnostic radiology, mammography and radiotherapy levels) in accordance to international recommendations. They presented good performance. The determination procedure of personal dose equivalent, Hp (10), was established. (author)

  19. [On establishing comparative reference system for syndrome classification study from the thinking characteristics of syndrome differentiation dependent therapy].

    Science.gov (United States)

    Liu, Ping; Hu, Yi-yang; Ni, Li-qiang

    2006-05-01

    To create a comparative referential system for syndrome classification study by viewing from the thinking characteristics of TCM on syndrome differentiation dependent therapy (SDDT), through analyzing the thinking process of SDDT, and the basic features of disease, syndrome and prescription, combining the basic principles of modern evidence-based medicine and feasibility of establishing integrative disease-syndrome animal model. The practice of creating a comparative referential system based on clinical efficacy of prescription was discussed around syndrome pathogenesis and its relationship with disease and prescription, which was one of the important scientific problems in TCM syndrome study. The authors hold that, it may be one of the available approaches for the present study on integration of disease with syndrome by way of insisting on the thinking pathway of stressing the characteristics of TCM and intermerging with modern scientific design; on taking the efficacy of prescription as the comparative reference system to accumulate and improve unceasingly according to the TCM method of syndrome diagnosis inferred from effect of prescription with reverse thought (i.e., to differentiate syndrome from the effect of prescription), and thus build up the syndrome diagnostic standard on the solid clinical and scientific base.

  20. A score system for complete cytoreduction in selected recurrent ovarian cancer patients undergoing secondary cytoreductive surgery: predictors- and nomogram-based analyses.

    Science.gov (United States)

    Bogani, Giorgio; Tagliabue, Elena; Signorelli, Mauro; Ditto, Antonino; Martinelli, Fabio; Chiappa, Valentina; Mosca, Lavinia; Sabatucci, Ilaria; Leone Roberti Maggiore, Umberto; Lorusso, Domenica; Raspagliesi, Francesco

    2018-05-01

    To test the applicability of the Arbeitsgemeinschaft Gynäkologische Onkologie (AGO) and Memorial Sloan Kettering (MSK) criteria in predicting complete cytoreduction (CC) in patients undergoing secondary cytoreductive surgery (SCS) for recurrent ovarian cancer (ROC). Data of consecutive patients undergoing SCS were reviewed. The Arbeitsgemeinschaft Gynäkologische Onkologie OVARian cancer study group (AGO-OVAR) and MSK criteria were retrospectively applied. Nomograms, based on AGO criteria, MSK criteria and both AGO and MSK criteria were built in order to assess the probability to achieve CC at SCS. Overall, 194 patients met the inclusion criteria. CC was achieved in 161 (82.9%) patients. According to the AGO-OVAR criteria, we observed that CC was achieved in 87.0% of patients with positive AGO score. However, 45 out of 71 (63.4%) patients who did not fulfilled the AGO score had CC. Similarly, CC was achieved in 87.1%, 61.9% and 66.7% of patients for whom SCS was recommended, had to be considered and was not recommended, respectively. In order to evaluate the predictive value of the AGO-OVAR and MSK criteria we built 2 separate nomograms (c-index: 0.5900 and 0.5989, respectively) to test the probability to achieve CC at SCS. Additionally, we built a nomogram using both the aforementioned criteria (c-index: 0.5857). The AGO and MSK criteria help identifying patients deserving SCS. However, these criteria might be strict, thus prohibiting a beneficial treatment in patients who do not met these criteria. Further studies are needed to clarify factors predicting CC at SCS. Copyright © 2018. Asian Society of Gynecologic Oncology, Korean Society of Gynecologic Oncology.

  1. Systems Analysis Programs for Hands-on Integrated Reliability Evaluations (SAPHIRE), Version 5.0: Integrated Reliability and Risk Analysis System (IRRAS) reference manual. Volume 2

    International Nuclear Information System (INIS)

    Russell, K.D.; Kvarfordt, K.J.; Skinner, N.L.; Wood, S.T.; Rasmuson, D.M.

    1994-07-01

    The Systems Analysis Programs for Hands-on Integrated Reliability Evaluations (SAPHIRE) refers to a set of several microcomputer programs that were developed to create and analyze probabilistic risk assessments (PRAs), primarily for nuclear power plants. The Integrated Reliability and Risk Analysis System (IRRAS) is a state-of-the-art, microcomputer-based probabilistic risk assessment (PRA) model development and analysis tool to address key nuclear plant safety issues. IRRAS is an integrated software tool that gives the use the ability to create and analyze fault trees and accident sequences using a microcomputer. This program provides functions that range from graphical fault tree construction to cut set generation and quantification to report generation. Version 1.0 of the IRRAS program was released in February of 1987. Since then, many user comments and enhancements have been incorporated into the program providing a much more powerful and user-friendly system. This version has been designated IRRAS 5.0 and is the subject of this Reference Manual. Version 5.0 of IRRAS provides the same capabilities as earlier versions and ads the ability to perform location transformations, seismic analysis, and provides enhancements to the user interface as well as improved algorithm performance. Additionally, version 5.0 contains new alphanumeric fault tree and event used for event tree rules, recovery rules, and end state partitioning

  2. Using a generalised identity reference model with archetypes to support interoperability of demographics information in electronic health record systems.

    Science.gov (United States)

    Xu Chen; Berry, Damon; Stephens, Gaye

    2015-01-01

    Computerised identity management is in general encountered as a low-level mechanism that enables users in a particular system or region to securely access resources. In the Electronic Health Record (EHR), the identifying information of both the healthcare professionals who access the EHR and the patients whose EHR is accessed, are subject to change. Demographics services have been developed to manage federated patient and healthcare professional identities and to support challenging healthcare-specific use cases in the presence of diverse and sometimes conflicting demographic identities. Demographics services are not the only use for identities in healthcare. Nevertheless, contemporary EHR specifications limit the types of entities that can be the actor or subject of a record to health professionals and patients, thus limiting the use of two level models in other healthcare information systems. Demographics are ubiquitous in healthcare, so for a general identity model to be usable, it should be capable of managing demographic information. In this paper, we introduce a generalised identity reference model (GIRM) based on key characteristics of five surveyed demographic models. We evaluate the GIRM by using it to express the EN13606 demographics model in an extensible way at the metadata level and show how two-level modelling can support the exchange of instances of demographic identities. This use of the GIRM to express demographics information shows its application for standards-compliant two-level modelling alongside heterogeneous demographics models. We advocate this approach to facilitate the interoperability of identities between two-level model-based EHR systems and show the validity and the extensibility of using GIRM for the expression of other health-related identities.

  3. Assessment of post closure radioactive safety for the Korean reference disposal system: development of scenarios and quantitative assessment

    International Nuclear Information System (INIS)

    Kang, C. H.; Hwang, Y. S.; Lee, Y. M.

    2005-01-01

    The total system performance assessment (TSPA) on the Korean reference disposal system has been performed for different types of scenarios. Firstly two reference scenarios, the natural discharge and well ones are developed assessed. The natural discharge scenario assumes that a radionuclide is released from a waste container with an average lifetime of 1,000 years by intruding groundwater to a biosphere through a bentonite buffer and a natural barrier composed of a fractured porous rock and a major water conducting feature (MWCF). The well scenario describes that a radionuclide passing through a buffer enters a fractured rock which is intersected with a drinking well. Two scenarios are named as R1 and R2 respectively. The third scenario is for the initial waste container failure case. A waste container is apt to have initial defects during manufacturing and transportation to a deposition hole. The probability function of the ratio of waste container failure is assumed based on the engineering sense. The rest of waste containers are assumed to have full function of isolation of hazardous nuclides during the lifetime. This initial container failure scenario (ICF) has two different variations: one with a lifetime of 1,000 years ana the other with 10,000 years. Two variations are assessed for two different biosphere, natural discharge and well. The forth one is to assess the impact of excavation disturbed zones. Deposition tunnels are excavated by tunnel boring machine (TBM) or controlled blast (CB). The disturbed zone in assumed to be 30 cm and 1 meter for TBN and CB respectively. Six cases are developed for the EDZ scenarios considering all possible combination of changes in permeability a fracture aperture, and a porosity of a fractured rock. The fifth scenario stipulates the change of long term climate (LTC). The ice age assumed to be prevailed again after a few tens of thousand years. The advent of the ice age alters groundwater composition, pathways, and most

  4. REFERENCE LEGAL SYSTEM “ConsultantPlus” AS A TOOL FOR IMPLEMENTING INTERDISCIPLINARY CONNECTIONS IN HIGH SCHOOL

    Directory of Open Access Journals (Sweden)

    Galina Viktorovna Hamer

    2017-12-01

    Full Text Available The standards for higher education provide for the development of students a comprehensive, universal, General and professional competencies through interdisciplinary connections. As practice shows, in the teaching of various disciplines, effective use of reference legal systems (RLS “ConsultantPlus”. Development opportunities RLS is an important component of training future specialists. It starts with the first courses of study in basic disciplines and should be used in the future during the period of training for regulatory support of various disciplines of specialization. Purpose Development and subsequent introduction in the educational process RLS “ConsultantPlus”as an effective tool for the realization of connections between disciplines. Methodology: used interactive teaching methods, and statistical methods of analysis of the impact of research. Results: improving the quality of study RLS “ConsultantPlus”, gain experience in solving actual practical problems, effective monitoring of students ‘ knowledge. Practical implications: developed by the technology study RLS “ConsultantPlus” should be used in University education in the study of various disciplines: legal, disciplines of information technology, statistical, special subjects to the effective development necessary to the future experts skills.

  5. Development of a Reference Image Collection Library for Histopathology Image Processing, Analysis and Decision Support Systems Research.

    Science.gov (United States)

    Kostopoulos, Spiros; Ravazoula, Panagiota; Asvestas, Pantelis; Kalatzis, Ioannis; Xenogiannopoulos, George; Cavouras, Dionisis; Glotsos, Dimitris

    2017-06-01

    Histopathology image processing, analysis and computer-aided diagnosis have been shown as effective assisting tools towards reliable and intra-/inter-observer invariant decisions in traditional pathology. Especially for cancer patients, decisions need to be as accurate as possible in order to increase the probability of optimal treatment planning. In this study, we propose a new image collection library (HICL-Histology Image Collection Library) comprising 3831 histological images of three different diseases, for fostering research in histopathology image processing, analysis and computer-aided diagnosis. Raw data comprised 93, 116 and 55 cases of brain, breast and laryngeal cancer respectively collected from the archives of the University Hospital of Patras, Greece. The 3831 images were generated from the most representative regions of the pathology, specified by an experienced histopathologist. The HICL Image Collection is free for access under an academic license at http://medisp.bme.teiath.gr/hicl/ . Potential exploitations of the proposed library may span over a board spectrum, such as in image processing to improve visualization, in segmentation for nuclei detection, in decision support systems for second opinion consultations, in statistical analysis for investigation of potential correlations between clinical annotations and imaging findings and, generally, in fostering research on histopathology image processing and analysis. To the best of our knowledge, the HICL constitutes the first attempt towards creation of a reference image collection library in the field of traditional histopathology, publicly and freely available to the scientific community.

  6. Determination of uncertainty of automated emission measuring systems under field conditions using a second method as a reference

    Energy Technology Data Exchange (ETDEWEB)

    Puustinen, H.; Aunela-Tapola, L.; Tolvanen, M.; Vahlman, T. [VTT Chemical Technology, Espoo (Finland). Environmental Technology; Kovanen, K. [VTT Building Technology, Espoo (Finland). Building Physics, Building Services and Fire Technology

    1999-09-01

    This report presents a procedure to determine the uncertainty of an automated emission measuring system (AMS) by comparing the results with a second method (REF). The procedure determines the uncertainty of AMS by comparing the final concentration and emission results of AMS and REF. In this way, the data processing of the plant is included in the result evaluation. This procedure assumes that the uncertainty of REF is known and determined in due form. The uncertainty determination has been divided into two cases; varying and nearly constant concentration. The suggested procedure calculates the uncertainty of AMS at the 95 % confidence level by a tabulated t-value. A minimum of three data pairs is required. However, a higher amount of data pairs is desirable, since a low amount of data pairs results in a higher uncertainty of AMS. The uncertainty of AMS is valid only within the range of concentrations at which the tests were carried out. Statistical data processing shows that the uncertainty of the reference method has a significant effect on the uncertainty of AMS, which always becomes larger than the uncertainty of REF. This should be taken into account when testing whether AMS fulfils the given uncertainty limits. Practical details, concerning parallel measurements at the plant, and the costs of the measurement campaign, have been taken into account when suggesting alternative ways for implementing the comparative measurements. (orig.) 6 refs.

  7. An Assessment of Technical and Production Risks of Candidate Low-Cost Attitude/Heading Reference Systems(AHRS)

    Science.gov (United States)

    Yuchnovicz, Daniel; Burgess, Malcolm; Hammers, William

    1999-01-01

    This report provides an assessment of technical and production risks of candidate low-cost attitude/heading reference systems (AHRS) for use in the Advanced General Aviation Transport Experiments (AGATE) airplanes. A low-cost AHRS is a key component of modem "glass cockpit" flight displays for General Aviation (GA) aircraft. The technical capabilities of several candidate low-cost AHRS were examined and described along with the technical issues involved with using all solid-state components for attitude measurement. An economic model was developed which describes the expected profit, rate of return, and volume requirements for the manufacture of low-cost AHRS for GA aircraft in the 2000 to 2020 time frame. The model is the result of interviews with GA airframe manufacturers, avionics manufacturers and historical analysis of avionics of similar complexity. The model shows that a manufacturer will break even after three years of AHRS production, realizing an 18 percent rate of return (23 percent profit) on an investment of $3.5M over the 20 year period. A start-up production estimate showed costs of $6-12M for a new company to build and certify an AHRS from scratch, considered to be a high-risk proposition, versus $0.25-0.75M for an experienced avionics manufacturer to manufacture a design under license, a low-risk proposition.

  8. Quality assurance in CT: implementation of the updated national diagnostic reference levels using an automated CT dose monitoring system.

    Science.gov (United States)

    Appel, E; Kröpil, P; Bethge, O T; Aissa, J; Thomas, C; Antoch, G; Boos, J

    2018-03-20

    To evaluate the implementation of the updated computed tomography (CT) diagnostic reference levels (DRLs) from the German Federal Office for Radiation Protection into clinical routine using an automatic CT dose monitoring system. CT radiation exposure was analysed before and after implementing the updated national DRLs into routine clinical work in 2016. After the implementation process, institutional CT protocols were mapped to the anatomical regions for which DRLs were provided. Systematically, protocols that exceeded the thresholds were optimised and analysed in detail. The CT radiation output parameters analysed were volumetric CT dose index (CTDIvol) and dose-length product (DLP). Three radiologists evaluated subjective image quality using a three-point Likert scale. The study included 94,258 CT series (from 27,103 CT examinations) in adult patients performed in 2016. When averaged over all body regions with available DRL, institutional CTDIvol/DLP values were always below the DRLs (65.2±32.9%/67.3±41.5% initially; 59.4±32%/60.5±39.9% after optimisation). Values exceeding the national DRLs were found for pelvis (n=268; CTDIvol 107.7±65.7%/DLP 106.3±79.3%), lumbar spine (n=91; 160.8±74.7%/175.2±104.1%), and facial bones (n=527; 108±39%/152.7±75.7%). After optimisation, CTDIvol and DLP were 87.9±73%/87.8±80.8% for the pelvis, 67.8±33.2%/74.5±50.6% for the lumbar spine and 95.1±45.8%/133.3±74.6% for the viscerocranium. An automatic CT dose monitoring system enabled not only comprehensive monitoring of a DRL implementation process but can also help to optimise radiation exposure. Copyright © 2018 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  9. Diagnosis of pulmonary tuberculosis by score system in children and adolescents: a trial in a reference center in Bahia, Brazil

    Directory of Open Access Journals (Sweden)

    Clemax Couto Sant'Anna

    Full Text Available Since 2002, the Brazilian Ministry of Health has recommended a score system for tuberculosis diagnosis of children and adolescents that does not need bacteriological positivity, because most cases in this age group have few bacteria. An observational, transversal study was carried out at the outpatient health care service of the reference medical service in Salvador, Bahia, including 164 patients with pulmonary tuberculosis, with ages ranging between 1 and 15 years of age, who were treated from 1990 to 2001. The gold standard used to establish the diagnosis was clinical, radiological, epidemiological and based on follow-up data. The score system for diagnosis purposes was tested retrospectively. The median age and the average age of the 164 patients were 6 and 6.62 years (SD ± 4.33, respectively. About 65% of the sample reported a history of close contact with a tuberculous adult. The BCG vaccine coverage was 70.7% (116/164. It was found that 26% (43/164 of the patients had severe malnutrition. Out of this group, 26/43 (60.47% were < 5mm reactive to the tuberculin test. On the other hand, out of the 91 patients with tuberculin test < 5mm, 29% (26/ 91 had severe malnutrition. The use of the score gave the following distribution: a TB very likely in 81.7% (134/164 of the patients; b possible TB in 15.9% (26/164 and TB unlikely in 2.4% (4/164. Among patients who had been vaccinated more than 2 years before, there was a 9 times higher risk of finding a tuberculin test above 10 mm in individuals with probable TB in comparison with the patients with possible or unlikely TB.

  10. Handbook of reference electrodes

    CERN Document Server

    Inzelt, György; Scholz, Fritz

    2013-01-01

    Reference Electrodes are a crucial part of any electrochemical system, yet an up-to-date and comprehensive handbook is long overdue. Here, an experienced team of electrochemists provides an in-depth source of information and data for the proper choice and construction of reference electrodes. This includes all kinds of applications such as aqueous and non-aqueous solutions, ionic liquids, glass melts, solid electrolyte systems, and membrane electrodes. Advanced technologies such as miniaturized, conducting-polymer-based, screen-printed or disposable reference electrodes are also covered. Essen

  11. Development of the regional EPR and PACS sharing system on the infrastructure of cloud computing technology controlled by patient identifier cross reference manager.

    Science.gov (United States)

    Kondoh, Hiroshi; Teramoto, Kei; Kawai, Tatsurou; Mochida, Maki; Nishimura, Motohiro

    2013-01-01

    A Newly developed Oshidori-Net2, providing medical professionals with remote access to electronic patient record systems (EPR) and PACSs of four hospitals, of different venders, using cloud computing technology and patient identifier cross reference manager. The operation was started from April 2012. The patients moved to other hospital were applied. Objective is to show the merit and demerit of the new system.

  12. Validation of automated screening for referable diabetic retinopathy with the IDx-DR device in the Hoorn Diabetes Care System.

    Science.gov (United States)

    van der Heijden, Amber A; Abramoff, Michael D; Verbraak, Frank; van Hecke, Manon V; Liem, Albert; Nijpels, Giel

    2018-02-01

    To increase the efficiency of retinal image grading, algorithms for automated grading have been developed, such as the IDx-DR 2.0 device. We aimed to determine the ability of this device, incorporated in clinical work flow, to detect retinopathy in persons with type 2 diabetes. Retinal images of persons treated by the Hoorn Diabetes Care System (DCS) were graded by the IDx-DR device and independently by three retinal specialists using the International Clinical Diabetic Retinopathy severity scale (ICDR) and EURODIAB criteria. Agreement between specialists was calculated. Results of the IDx-DR device and experts were compared using sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV), distinguishing between referable diabetic retinopathy (RDR) and vision-threatening retinopathy (VTDR). Area under the receiver operating characteristic curve (AUC) was calculated. Of the included 1415 persons, 898 (63.5%) had images of sufficient quality according to the experts and the IDx-DR device. Referable diabetic retinopathy (RDR) was diagnosed in 22 persons (2.4%) using EURODIAB and 73 persons (8.1%) using ICDR classification. Specific intergrader agreement ranged from 40% to 61%. Sensitivity, specificity, PPV and NPV of IDx-DR to detect RDR were 91% (95% CI: 0.69-0.98), 84% (95% CI: 0.81-0.86), 12% (95% CI: 0.08-0.18) and 100% (95% CI: 0.99-1.00; EURODIAB) and 68% (95% CI: 0.56-0.79), 86% (95% CI: 0.84-0.88), 30% (95% CI: 0.24-0.38) and 97% (95% CI: 0.95-0.98; ICDR). The AUC was 0.94 (95% CI: 0.88-1.00; EURODIAB) and 0.87 (95% CI: 0.83-0.92; ICDR). For detection of VTDR, sensitivity was lower and specificity was higher compared to RDR. AUC's were comparable. Automated grading using the IDx-DR device for RDR detection is a valid method and can be used in primary care, decreasing the demand on ophthalmologists. © 2017 The Authors. Acta Ophthalmologica published by John Wiley & Sons Ltd on behalf of Acta Ophthalmologica Scandinavica

  13. Identification of phlebotomine sand flies using one MALDI-TOF MS reference database and two mass spectrometer systems.

    Science.gov (United States)

    Mathis, Alexander; Depaquit, Jérôme; Dvořák, Vit; Tuten, Holly; Bañuls, Anne-Laure; Halada, Petr; Zapata, Sonia; Lehrter, Véronique; Hlavačková, Kristýna; Prudhomme, Jorian; Volf, Petr; Sereno, Denis; Kaufmann, Christian; Pflüger, Valentin; Schaffner, Francis

    2015-05-10

    Rapid, accurate and high-throughput identification of vector arthropods is of paramount importance in surveillance programmes that are becoming more common due to the changing geographic occurrence and extent of many arthropod-borne diseases. Protein profiling by MALDI-TOF mass spectrometry fulfils these requirements for identification, and reference databases have recently been established for several vector taxa, mostly with specimens from laboratory colonies. We established and validated a reference database containing 20 phlebotomine sand fly (Diptera: Psychodidae, Phlebotominae) species by using specimens from colonies or field-collections that had been stored for various periods of time. Identical biomarker mass patterns ('superspectra') were obtained with colony- or field-derived specimens of the same species. In the validation study, high quality spectra (i.e. more than 30 evaluable masses) were obtained with all fresh insects from colonies, and with 55/59 insects deep-frozen (liquid nitrogen/-80 °C) for up to 25 years. In contrast, only 36/52 specimens stored in ethanol could be identified. This resulted in an overall sensitivity of 87 % (140/161); specificity was 100 %. Duration of storage impaired data counts in the high mass range, and thus cluster analyses of closely related specimens might reflect their storage conditions rather than phenotypic distinctness. A major drawback of MALDI-TOF MS is the restricted availability of in-house databases and the fact that mass spectrometers from 2 companies (Bruker, Shimadzu) are widely being used. We have analysed fingerprints of phlebotomine sand flies obtained by automatic routine procedure on a Bruker instrument by using our database and the software established on a Shimadzu system. The sensitivity with 312 specimens from 8 sand fly species from laboratory colonies when evaluating only high quality spectra was 98.3 %; the specificity was 100 %. The corresponding diagnostic values with 55 field

  14. Uvođenje novih geodetskih referentnih sistema u Bosni i Hercegovini : Introduction of a new geodetic reference systems in Bosnia and Herzegovina

    Directory of Open Access Journals (Sweden)

    Šeho Zimić

    2017-12-01

    Full Text Available The introduction of a new reference system in Bosnia and Herzegovina is not only a necessity, but an obligation imposed by the United Nations (UN and the European Union (EU. At the General Assembly on February 26, 2015, the UN has adopted a resolution titled "Global Geodetic Reference Frame for Sustainable Development - GGRF", which for the first time raise the geodetic issue as a political issue at such a high level. The resolution highlights the strong need for more precise positioning and navigation from the use of smartphones to the study of climate changes, population migrations and other scientific researches of relevance to the whole world (http://www.unggrf.org/. All this is not possible without a global exchange of geodata and a common global geodetic reference system. Through the Inspire Directive, the EU has clearly specified which coordinate and heights systems are being applied in Europe. The countries in the region have adopted the European terrestrial reference system ETRS89 as a new reference system in their legislation. Through the EUREF campaign BALKAN98 and the introduction of the Network of permanent GNSS stations Bosnia and Herzegovina has joined the famil

  15. Application of ANFIS and SVM Systems in Order to Estimate Monthly Reference Crop Evapotranspiration in the Northwest of Iran

    Directory of Open Access Journals (Sweden)

    F. Ahmadi

    2016-10-01

    Full Text Available Introduction Crop evapotranspiration modeling process mainly performs with empirical methods, aerodynamic and energy balance. In these methods, the evapotranspiration is calculated based on the average values of meteorological parameters at different time steps. The linear models didn’t have a good performance in this field due to high variability of evapotranspiration and the researchers have turned to the use of nonlinear and intelligent models. For accurate estimation of this hydrologic variable, it should be spending much time and money to measure many data (19. Materials and Methods Recently the new hybrid methods have been developed by combining some of methods such as artificial neural networks, fuzzy logic and evolutionary computation, that called Soft Computing and Intelligent Systems. These soft techniques are used in various fields of engineering. A fuzzy neurosis is a hybrid system that incorporates the decision ability of fuzzy logic with the computational ability of neural network, which provides a high capability for modeling and estimating. Basically, the Fuzzy part is used to classify the input data set and determines the degree of membership (that each number can be laying between 0 and 1 and decisions for the next activity made based on a set of rules and move to the next stage. Adaptive Neuro-Fuzzy Inference Systems (ANFIS includes some parts of a typical fuzzy expert system which the calculations at each step is performed by the hidden layer neurons and the learning ability of the neural network has been created to increase the system information (9. SVM is a one of supervised learning methods which used for classification and regression affairs. This method was developed by Vapink (15 based on statistical learning theory. The SVM is a method for binary classification in an arbitrary characteristic space, so it is suitable for prediction problems (12. The SVM is originally a two-class Classifier that separates the classes

  16. The Uhlenbeck-Ford model: Exact virial coefficients and application as a reference system in fluid-phase free-energy calculations

    Science.gov (United States)

    Paula Leite, Rodolfo; Freitas, Rodrigo; Azevedo, Rodolfo; de Koning, Maurice

    2016-11-01

    The Uhlenbeck-Ford (UF) model was originally proposed for the theoretical study of imperfect gases, given that all its virial coefficients can be evaluated exactly, in principle. Here, in addition to computing the previously unknown coefficients B11 through B13, we assess its applicability as a reference system in fluid-phase free-energy calculations using molecular simulation techniques. Our results demonstrate that, although the UF model itself is too soft, appropriately scaled Uhlenbeck-Ford (sUF) models provide robust reference systems that allow accurate fluid-phase free-energy calculations without the need for an intermediate reference model. Indeed, in addition to the accuracy with which their free energies are known and their convenient scaling properties, the fluid is the only thermodynamically stable phase for a wide range of sUF models. This set of favorable properties may potentially put the sUF fluid-phase reference systems on par with the standard role that harmonic and Einstein solids play as reference systems for solid-phase free-energy calculations.

  17. National Health and Nutrition Examination Survey whole-body dual-energy X-ray absorptiometry reference data for GE Lunar systems.

    Science.gov (United States)

    Fan, Bo; Shepherd, John A; Levine, Michael A; Steinberg, Dee; Wacker, Wynn; Barden, Howard S; Ergun, David; Wu, Xin P

    2014-01-01

    The National Health and Nutrition Examination Survey (NHANES 1999-2004) includes adult and pediatric comparisons for total body bone and body composition results. Because dual-energy x-ray absorptiometry (DXA) measurements from different manufacturers are not standardized, NHANES reference values currently are applicable only to a single make and model of Hologic DXA system. The purpose of this study was to derive body composition reference curves for GE Healthcare Lunar DXA systems. Published values from the NHANES 1999-2004 survey were acquired from the Centers for Disease Control and Prevention website. Using previously reported cross-calibration equations between Hologic and GE-Lunar, we converted the total body and regional bone and soft-tissue measurements from NHANES 1999-2004 to GE-Lunar values. The LMS (LmsChartMaker Pro Version 3.5) curve fitting method was used to generate GE-Lunar reference curves. Separate curves were generated for each sex and ethnicity. The reference curves were also divided into pediatric (≤20 years old) and adult (>20 years old) groups. Adult reference curves were derived as a function of age. Additional relationships of pediatric DXA values were derived as a function of height, lean mass, and bone area. Robustness was tested between Hologic and GE-Lunar Z-score values. The NHANES 1999-2004 survey included a sample of 20,672 participants' (9630 female) DXA scans. A total of 8056 participants were younger than 20 yr and were included in the pediatric reference data set. Participants enrolled in the study who weighed more than 136 kg (over scanner table limit) were excluded. The average Z-scores comparing the new GE-Lunar reference curves are close to zero, and the standard deviation of the Z-scores are close to one for all variables. As expected, all measurements on the GE-Lunar reference curves for participants younger than 20 yr increase monotonically with age. In the adult population, most of the curves are constant at younger

  18. Memory systems in the rat: effects of reward probability, context, and congruency between working and reference memory.

    Science.gov (United States)

    Roberts, William A; Guitar, Nicole A; Marsh, Heidi L; MacDonald, Hayden

    2016-05-01

    The interaction of working and reference memory was studied in rats on an eight-arm radial maze. In two experiments, rats were trained to perform working memory and reference memory tasks. On working memory trials, they were allowed to enter four randomly chosen arms for reward in a study phase and then had to choose the unentered arms for reward in a test phase. On reference memory trials, they had to learn to visit the same four arms on the maze on every trial for reward. Retention was tested on working memory trials in which the interval between the study and test phase was 15 s, 15 min, or 30 min. At each retention interval, tests were performed in which the correct WM arms were either congruent or incongruent with the correct RM arms. Both experiments showed that congruency interacted with retention interval, yielding more forgetting at 30 min on incongruent trials than on congruent trials. The effect of reference memory strength on the congruency effect was examined in Experiment 1, and the effect of associating different contexts with working and reference memory on the congruency effect was studied in Experiment 2.

  19. The utility of optical detection system (qPCR) and bioinformatics methods in reference gene expression analysis

    Science.gov (United States)

    Skarzyńska, Agnieszka; Pawełkowicz, Magdalena; PlÄ der, Wojciech; Przybecki, Zbigniew

    2016-09-01

    Real-time quantitative polymerase chain reaction is consider as the most reliable method for gene expression studies. However, the expression of target gene could be misinterpreted due to improper normalization. Therefore, the crucial step for analysing of qPCR data is selection of suitable reference genes, which should be validated experimentally. In order to choice the gene with stable expression in the designed experiment, we performed reference gene expression analysis. In this study genes described in the literature and novel genes predicted as control genes, based on the in silico analysis of transcriptome data were used. Analysis with geNorm and NormFinder algorithms allow to create the ranking of candidate genes and indicate the best reference for flower morphogenesis study. According to the results, genes CACS and CYCL were characterised the most stable expression, but the least suitable genes were TUA and EF.

  20. A retrospective matched cohort study evaluating the effects of percutaneous endoscopic gastrostomy feeding tubes on nutritional status and survival in patients with advanced gastroesophageal malignancies undergoing systemic anti-cancer therapy.

    Science.gov (United States)

    Mitchell, Scott; Williams, John P; Bhatti, Harsimrandeep; Kachaamy, Toufic; Weber, Jeffrey; Weiss, Glen J

    2017-01-01

    Many patients with cancer or other systemic illnesses can experience malnutrition. One way to mitigate malnutrition is by insertion of a percutaneous endoscopic gastrostomy feeding tube (PEG tube). The goal of this retrospective matched cohort study is to evaluate if PEG tube placement improved nutritional status and overall survival (OS) in advanced gastroesophageal (GE) cancer patients who are undergoing anti-neoplastic therapy. GE cancer patients who were treated and evaluated by a nutritionist and had at least 2 nutritionist follow-up visits were identified. Patients with PEG tube were matched to patients that did not undergo PEG placement (non-PEG). Clinical characteristics, GE symptoms reported at nutrition follow-up visits, and OS were recorded. 20 PEG and 18 non-PEG cases met criteria for further analyses. After correction for multiple testing, there were no OS differences between PEG and non-PEG, treatment naive and previously treated. However, PEG esophageal carcinoma has statistically significant inferior OS compared with non-PEG esophageal carcinoma. PEG placement did not significantly reduce the proportion of patients with weight loss between the initial nutrition assessment and 12-week follow-up. In this small study, PEG placement had inferior OS outcome for GE esophageal carcinoma, no improvement in OS for other evaluated groups, and did not reduce weight loss between baseline and 12-week follow-up. Unless there is prospective randomized trial that can show superiority of PEG placement in this population, PEG placement in this group cannot be endorsed.

  1. Reference ranges for blood concentrations of eosinophils and monocytes during the neonatal period defined from over 63 000 records in a multihospital health-care system.

    Science.gov (United States)

    Christensen, R D; Jensen, J; Maheshwari, A; Henry, E

    2010-08-01

    Blood concentrations of eosinophils and monocytes are part of the complete blood count. Reference ranges for these concentrations during the neonatal period, established by very large sample sizes and modern methods, are needed for identifying abnormally low or high values. We constructed reference ranges for eosinophils per microl and monocytes per microl among neonates of 22 to 42 weeks of gestation, on the day of birth, and also during 28 days after birth. Data were obtained from archived electronic records over an eight and one-half-year period in a multihospital health-care system. In keeping with the reference range concept, values were excluded from neonates with a diagnosis of infection or necrotizing enterocolitis (NEC). Eosinophils and monocytes per microl of blood were electronically retrieved from 96 162 records, of which 63 371 that lacked a diagnosis of infection or NEC were included in this reference range report. The mean value for eosinophils per microl on the day of birth increased linearly between 22 and 42 weeks of gestation, as did the 5 and 95% values. The reference range at 40 weeks was 140 to 1300 microl(-1) (mean 550 microl(-1)). Similarly, the mean value for monocytes increased linearly over this interval, with a reference range at 40 weeks of 300 to 3300 microl(-1) (mean 1400 microl(-1)). Over the first 4 weeks after birth, no appreciable change was observed in 5% limit and mean eosinophil count, with a slight increase in the 95% limit in week 4. A slight increase in monocyte count was observed during the first 2 weeks after birth. The results of this analysis describe reference ranges for blood concentrations of eosinophils and monocytes during the neonatal period. Additional study is needed for determining the relevance of values falling outside the reference range.

  2. A model reference and sensitivity model-based self-learning fuzzy logic controller as a solution for control of nonlinear servo systems

    NARCIS (Netherlands)

    Kovacic, Z.; Bogdan, S.; Balenovic, M.

    1999-01-01

    In this paper, the design, simulation and experimental verification of a self-learning fuzzy logic controller (SLFLC) suitable for the control of nonlinear servo systems are described. The SLFLC contains a learning algorithm that utilizes a second-order reference model and a sensitivity model

  3. Identification of phlebotomine sand flies using one MALDI-TOF MS reference database and two mass spectrometer systems

    Czech Academy of Sciences Publication Activity Database

    Mathis, A.; Depaquit, J.; Dvořák, V.; Tuten, H.; Banuls, A.-L.; Halada, Petr; Zapata, S.; Lehrter, V.; Hlaváčková, K.; Prudhomme, J.; Volf, P.; Sereno, D.; Kaufmann, Ch.; Pflueger, V.; Schaffner, F.

    2015-01-01

    Roč. 8, MAY 2015 (2015) ISSN 1756-3305 R&D Projects: GA ČR(CZ) GA15-04329S Institutional support: RVO:61388971 Keywords : Arthropod identification * Bruker * Centralized reference database Subject RIV: CE - Biochemistry Impact factor: 3.234, year: 2015

  4. Ground Receiving Station Reference Pair Selection Technique for a Minimum Configuration 3D Emitter Position Estimation Multilateration System

    Directory of Open Access Journals (Sweden)

    Abdulmalik Shehu Yaro

    2017-01-01

    Full Text Available Multilateration estimates aircraft position using the Time Difference Of Arrival (TDOA with a lateration algorithm. The Position Estimation (PE accuracy of the lateration algorithm depends on several factors which are the TDOA estimation error, the lateration algorithm approach, the number of deployed GRSs and the selection of the GRS reference used for the PE process. Using the minimum number of GRSs for 3D emitter PE, a technique based on the condition number calculation is proposed to select the suitable GRS reference pair for improving the accuracy of the PE using the lateration algorithm. Validation of the proposed technique was performed with the GRSs in the square and triangular GRS configuration. For the selected emitter positions, the result shows that the proposed technique can be used to select the suitable GRS reference pair for the PE process. A unity condition number is achieved for GRS pair most suitable for the PE process. Monte Carlo simulation result, in comparison with the fixed GRS reference pair lateration algorithm, shows a reduction in PE error of at least 70% for both GRS in the square and triangular configuration.

  5. Comparison of the 7(th) and proposed 8(th) editions of the AJCC/UICC TNM staging system for non-small cell lung cancer undergoing radical surgery.

    Science.gov (United States)

    Jin, Ying; Chen, Ming; Yu, Xinmin

    2016-09-19

    The present study aims to compare the 7(th) and the proposed 8(th) edition of the AJCC/UICC TNM staging system for NSCLC in a cohort of patients from a single institution. A total of 408 patients with NSCLC who underwent radical surgery were analyzed retrospectively. Survivals were analyzed using the Kaplan -Meier method and were compared using the log-rank test. Multivariate analysis was performed by the Cox proportional hazard model. The Akaike information criterion (AIC) and C-index were applied to compare the two prognostic systems with different numbers of stages. The 7(th) AJCC T categories, the proposed 8(th) AJCC T categories, N categories, visceral pleural invasion, and vessel invasion were found to have statistically significant associations with disease-free survival (DFS) on univariate analysis. In the 7(th) edition staging system as well as in the proposed 8(th) edition, T categories, N categories, and pleural invasion were independent factors for DFS on multivariate analysis. The AIC value was smaller for the 8(th) edition compared to the 7(th) edition staging system. The C-index value was larger for the 8(th) edition compared to the 7(th) edition staging system. Based on the data from our single center, the proposed 8(th) AJCC T classification seems to be superior to the 7(th) AJCC T classification in terms of DFS for patients with NSCLC underwent radical surgery.

  6. Robust model reference adaptive output feedback tracking for uncertain linear systems with actuator fault based on reinforced dead-zone modification.

    Science.gov (United States)

    Bagherpoor, H M; Salmasi, Farzad R

    2015-07-01

    In this paper, robust model reference adaptive tracking controllers are considered for Single-Input Single-Output (SISO) and Multi-Input Multi-Output (MIMO) linear systems containing modeling uncertainties, unknown additive disturbances and actuator fault. Two new lemmas are proposed for both SISO and MIMO, under which dead-zone modification rule is improved such that the tracking error for any reference signal tends to zero in such systems. In the conventional approach, adaption of the controller parameters is ceased inside the dead-zone region which results tracking error, while preserving the system stability. In the proposed scheme, control signal is reinforced with an additive term based on tracking error inside the dead-zone which results in full reference tracking. In addition, no Fault Detection and Diagnosis (FDD) unit is needed in the proposed approach. Closed loop system stability and zero tracking error are proved by considering a suitable Lyapunov functions candidate. It is shown that the proposed control approach can assure that all the signals of the close loop system are bounded in faulty conditions. Finally, validity and performance of the new schemes have been illustrated through numerical simulations of SISO and MIMO systems in the presence of actuator faults, modeling uncertainty and output disturbance. Copyright © 2015 ISA. Published by Elsevier Ltd. All rights reserved.

  7. Application of the informational reference system OZhUR to the automated processing of data from satellites of the Kosmos series

    Science.gov (United States)

    Pokras, V. M.; Yevdokimov, V. P.; Maslov, V. D.

    1978-01-01

    The structure and potential of the information reference system OZhUR designed for the automated data processing systems of scientific space vehicles (SV) is considered. The system OZhUR ensures control of the extraction phase of processing with respect to a concrete SV and the exchange of data between phases.The practical application of the system OZhUR is exemplified in the construction of a data processing system for satellites of the Cosmos series. As a result of automating the operations of exchange and control, the volume of manual preparation of data is significantly reduced, and there is no longer any need for individual logs which fix the status of data processing. The system Ozhur is included in the automated data processing system Nauka which is realized in language PL-1 in a binary one-address system one-state (BOS OS) electronic computer.

  8. SU-E-T-317: The Development of a DIBH Technique for Left Sided Breast Patients Undergoing Radiation Therapy Utilizing Varians RPM System in a Community Hospital

    International Nuclear Information System (INIS)

    Hasson, B; Young, M; Workie, D; Geraghty, C

    2014-01-01

    Purpose: To develop and implement a Deep Inhalation Breath Hold program (DIBH) for treatment of patients with Left-sided breast cancer in a community hospital. Methods: All patients with left sided breast cancer underwent a screening free breathing CT. Evaluation of the conventional tangent treatment fields and the heart was conducted. If the heart would not be excluded using tangents, the patient then received DIBH breathe coaching. The patients returned for a 4D CT simulation. The patients breathing cycle was monitored using the Varian Real-Time position ManagementTM (RPM) system to assess duration of DIBH, amplitude, phase and recovery time to normal breathing. Then a DIBH CT was obtained at the desired amplitude. Duplicate plans were developed for both free breathing and DIBH on the Eclipse planning system and comparison DVH's were created. The plan that provided the prescribed treatment coverage and the least doses to the OAR (heart, Lt. Lung) was determined. Those patients selected to receive treatment with DIBH were set up for treatment, and breathing was monitored using the RPM system. Practice trials were used to confirm that the amplitude, phase and recovery were consistent with findings from simulation. Results: 10 patients have been treated using the DIBH procedure in our clinic. The DIBH patients had an average increase of 80% lung volume on DIBH, decreased lung volume receiving 50% of the dose, and decreases in the V20 dose. Significant reduction in the maximum and mean dose to the heart, as well as the dose to 1CC of the volume for the DIBH plans. Conclusion: Using the RPM system already available in the clinic, staff training, and patient coaching a simple DIBH program was setup. The use of DIBH has shown promise in reducing doses to the critical organs while maintaining PTV coverage for left sided breast treatments

  9. SU-E-T-317: The Development of a DIBH Technique for Left Sided Breast Patients Undergoing Radiation Therapy Utilizing Varians RPM System in a Community Hospital

    Energy Technology Data Exchange (ETDEWEB)

    Hasson, B; Young, M; Workie, D; Geraghty, C [Anne Arundel Medical Center, Annapolis, MD (United States)

    2014-06-01

    Purpose: To develop and implement a Deep Inhalation Breath Hold program (DIBH) for treatment of patients with Left-sided breast cancer in a community hospital. Methods: All patients with left sided breast cancer underwent a screening free breathing CT. Evaluation of the conventional tangent treatment fields and the heart was conducted. If the heart would not be excluded using tangents, the patient then received DIBH breathe coaching. The patients returned for a 4D CT simulation. The patients breathing cycle was monitored using the Varian Real-Time position ManagementTM (RPM) system to assess duration of DIBH, amplitude, phase and recovery time to normal breathing. Then a DIBH CT was obtained at the desired amplitude. Duplicate plans were developed for both free breathing and DIBH on the Eclipse planning system and comparison DVH's were created. The plan that provided the prescribed treatment coverage and the least doses to the OAR (heart, Lt. Lung) was determined. Those patients selected to receive treatment with DIBH were set up for treatment, and breathing was monitored using the RPM system. Practice trials were used to confirm that the amplitude, phase and recovery were consistent with findings from simulation. Results: 10 patients have been treated using the DIBH procedure in our clinic. The DIBH patients had an average increase of 80% lung volume on DIBH, decreased lung volume receiving 50% of the dose, and decreases in the V20 dose. Significant reduction in the maximum and mean dose to the heart, as well as the dose to 1CC of the volume for the DIBH plans. Conclusion: Using the RPM system already available in the clinic, staff training, and patient coaching a simple DIBH program was setup. The use of DIBH has shown promise in reducing doses to the critical organs while maintaining PTV coverage for left sided breast treatments.

  10. The Role of Radio Frequency Detection System Embedded Surgical Sponges in Preventing Retained Surgical Sponges: A Prospective Evaluation in Patients Undergoing Emergency Surgery.

    Science.gov (United States)

    Inaba, Kenji; Okoye, Obi; Aksoy, Hande; Skiada, Dimitra; Ault, Glenn; Sener, Stephen; Lam, Lydia; Benjamin, Elizabeth; Demetriades, Demetrios

    2016-10-01

    To prospectively evaluate the ability of radio frequency detection (RFD) system-embedded sponges to mitigate the incidence of retained surgical sponges (RSS) after emergency surgery. Emergency surgery patients are at high risk for retained foreign bodies. All emergent trauma and nontrauma cavitary operations over a 5-year period (January 2010-December 2014) were prospectively enrolled. For damage-control procedures, only the definitive closure was included. RFD sponges were used exclusively throughout the study period. Before closure, the sponge and instrument count was followed by RFD scanning and x-ray evaluation for retained sponges. RSS and near-misses averted using the RFD system were analyzed. In all, 2051 patients [median (range)], aged 41 (1-101) years, 72.2% male, 46.8% trauma patients, underwent 2148 operations (1824 laparotomy, 100 thoracotomy, 30 sternotomy, and 97 combined). RFD detected retained sponges in 11 (0.5%) patients (81.8%laparotomy, 18.2% sternotomy) before cavitary closure. All postclosure x-rays were negative. No retained sponges were missed by the RFD system. Body mass index was 29 (23-43), estimated blood loss 1.0 L (0-23), and operating room time 160 minutes (71-869). Procedures started after 18:00 to 06:00 hours in 45.5% of the patients. The sponge count was incorrect in 36.4%, not performed due to time constraints in 45.5%, and correct in 18.2%. The additional cost of using RFD-embedded disposables was $0.17 for a 4X18 laparotomy sponge and $0.46 for a 10 pack of 12ply, 4X8. Emergent surgical procedures are high-risk for retained sponges, even when sponge counts are performed and found to be correct. Implementation of a RFD system was effective in preventing this complication and should be considered for emergent operations in an effort to improve patient safety.

  11. Long-term exposure to jet fuel. An investigation on occupationally exposed workers with special reference to the nervous system

    Energy Technology Data Exchange (ETDEWEB)

    Knave, B; Persson, H E; Goldberg, M; Westerholm, P

    1976-09-01

    Chronic solvent intoxication due to jet fuel vapor was diagnosed after tests on 29 aircraft factory workers. The exposed subjects were classified into (1) heavily exposed and (2) less heavily exposed groups. Tests included a clinical neurological examination, measurements of the peipheral nerve conduction velocities and threshold determination of vibratory sensations in the extremities. All 13 examined in the first group and 7 of 16 in the second group stated that, on repeated occasions, they had experienced acute effects (dizziness, dyspnoea, heart palpitations, chest striction, nausea, headaches) of the jet fuel vapors in the inhaled air. Air overrepresentation of symptoms of neurasthenia and physical disturbances, polyneuropathic symptoms and plyneuropathic findings were evident from the neurological status both in the heavily exposed group and in the two groups taken as a whole when comparison was made with reference groups. Moreover, relatively lower nerve conduction velocities and higher vibration thresholds were witnessed in both groups compared with a reference group from the heavy metal industry.

  12. The impact of different definitions and reference groups on the prevalence of cognitive impairment: a study in postmenopausal breast cancer patients before the start of adjuvant systemic therapy.

    Science.gov (United States)

    Schilder, Christina M; Seynaeve, Caroline; Linn, Sabine C; Boogerd, Willem; Gundy, Chad M; Beex, Louk V; van Dam, Frits S; Schagen, Sanne B

    2010-04-01

    Several prospective studies into the effects of adjuvant systemic therapy on cognitive functioning suggest that a proportion of breast cancer patients show cognitive deficits already before the start of systemic therapy. Owing to, among others, methodological inconsistency, studies report different rates of this pre-treatment cognitive impairment. We examined the impact of four different criteria of cognitive impairment and two types of reference groups (a study-specific healthy reference group versus published normative data) on the prevalence of cognitive impairment. Two hundred and five postmenopausal breast cancer patients underwent a battery of neuropsychological tests before the start of endocrine therapy, 124 healthy subjects underwent the same tests. Proportions of cognitive impaired patients were calculated for each of four criteria for cognitive impairment, using (1) study-specific healthy controls and (2) published norms of healthy controls as reference groups. The prevalence of cognitive impairment varied greatly with the strictness of the criterion, as expected, but also was dependent on the reference group used. Cognitive impairment, relative to published norms, ranged from 1% for the strictest to 36.6% for the less strict criterion, cognitive impairment relative to study-specific healthy controls, ranged from 13.7 to 45.4% for the same criteria. This study highlights contrasting proportions of cognitive impairment by using different criteria for cognitive impairment and different reference groups. (Dis)advantages of the methods using a criterion for cognitive impairment, and of the use of published norms versus a study-specific reference group are discussed. Copyright 2009 John Wiley & Sons, Ltd.

  13. The Operational Hydro-meteorological Ensemble Prediction System at Meteo-France and its representation interface for the French Service for Flood Prediction (SCHAPI) : description and undergoing developments.

    Science.gov (United States)

    Rousset-Regimbeau, F.; Martin, E.; Thirel, G.; Habets, F.; Coustau, M.; Roquelaure, S.; De Saint Aubin, C.; Ardilouze, C.

    2012-04-01

    The coupled physically-based hydro-meteorological model SAFRAN-ISBA-MODCOU (SIM) is developed at Meteo-France for many years. This fully distributed catchment model is used in a pre-operational mode since 2005 for producing mid-range ensemble streamflow forecasts based on the 51-member 10-day ECMWF EPS. Improvements have been made during the past few years.. First, a statistical adaptation has been performed to improve the meteorological ensemble predictions from the ECMWF. It has been developped over a 3-year archive, and assessed over a 1-year period. Its impact on the performance of the streamflow forecasts has been calculated over 8 months of predictions. Then, a past discharges assimilation system has been implemented in order to improve the initial states of these ensemble streamflow forecasts. It has been developped in the framework of a Phd thesis, and it is now evaluated in real-time conditions. Moreover, an improvement of the physics of the ISBA model (the exponential profile of the hydraulic conductivity in the soil) was implemented. Finally, this system provides ensemble 10-day streamflow prediction to the French National Service for Flood Prediction (SCHAPI). A collaboration between Meteo-France and SCHAPI led to the development of a new website. This website shows the streamflow predictions for about 200 selected river stations over France (selected regarding their interest for flood warning) , as well as alerts for high flows (two levels of high flows corresponding to the levels of risk of the French flood warning system). It aims at providing to the French hydrological forecaters a real-time tool for mid-range flood awareness.

  14. ORTHO-LBNP: A new apparatus for assessing autocontrol mechanisms of the heart-vessel system in pilots undergoing training in conditions of ischemic hypoxia and orthostatic stress

    Science.gov (United States)

    Truszczynski, Olaf; Skibniewski, Franciszek; Dziuda, Lukasz; Gacek, Adam; Krej, Mariusz; Sobotnicki, Aleksander; Rajchel, Jan; Bylinka, Marek; Burek, Michal

    The authors present a new system for examining the behaviour of the human body and cerebral circulation in conditions of ischemic hypoxia and orthostatic stress that can cause orthostatic hypotension. Ischemic hypoxia affects mainly pilots of highly manoeuvrable aircraft, where long-lasting G forces not seldom reach 6-8 +Gz and can exceed the gravitational acceleration by ten times or more. Additionally, pilots are subjected to orthostatic hypotension in which abnormally low blood pressure is caused by pressure adjustment disorder and decreased stroke volume when changing body position rapidly. For several decades, these effects have been deeply investigated using human centrifuges or lower body negative pressure (LBNP) chambers. The latter method involves significantly less financial resources to carry out experiments and training, whereas the effects exerted on pilots, and the results of the training can be comparable. A group of researchers from the Military Institute of Aviation Medicine, Warszawa, Poland, and the Institute of Medical Technology and Equipment ITAM, Zabrze, Poland, are developing the innovative ORTHO-LBNP device based on the cradle principle and the LBNP method. The system will be implemented in a modern programme for training cadets of the Polish Air Force Academy, Dęblin, Poland. Together with other equipment such as a high-G centrifuge, pressure chambers, flight and spatial disorientation simulators as well as gymnastic training equipment for pilots (GTEP), the ORTHO-LBNP apparatus will be an element of the selection system of candidates for aviation. It is expected that the experimental studies will result in developing new indicators providing an objective assessment, whether examined persons possess the traits necessary for performing tasks related to the job of a pilot. It is highly probable that those indicators can be incorporated into routine checks for pilots, which in turn, can lead to improving the safety of flight operations and

  15. The OIE World Animal Health Information System: the role of OIE Reference Laboratories and Collaborating Centres in disease reporting.

    Science.gov (United States)

    Ben Jebara, K

    2010-12-01

    One of the main objectives of the World Organisation for Animal Health (OIE) is to ensure transparency in and knowledge of the world animal health situation. To achieve this objective, the OIE relies on its network of Member Countries, which is complemented by the activities of 221 Reference Laboratories (RLs) and Collaborating Centres. The RL mandate states that, in the case of positive results for diseases notifiable to the OIE, the laboratory should inform the OIE Delegate of the Member Country from which the samples originated and send a copy of the information to OIE Headquarters. However, since 2006 the OIE has received a lower than expected number of notifications from RLs, which implies eitherthat the majority of samples are sent to national laboratories or that some RLs are not fully complying with their mandate. The OIE sent a questionnaire to RLs in preparation for the Second Global Conference of OIE Reference Laboratories and Collaborating Centres (Paris, France, 21-23 June 2010). Two main factors emerged: the need for RLs to clarify their role and responsibilities in disease reporting and the need for an awareness campaign to sensitise national Veterinary Services to the importance of conducting more surveillance (and consequently of submitting samples to RLs) for all OIE-listed diseases. Reference laboratories indicated two main reasons for not sharing more data on positive samples with the OIE: i) a perceived contradiction between their mandate as OIE RLs and the standards of the International Organization for Standardization (ISO) dealing with confidentiality; and ii) certain Member Countries or stakeholders asking RLs not to share positive results with the OIE, for political or economic reasons. The OIE has put forward proposals to help RLs resolve these problems in future. The use of ISO standards must be clarified and there must be improved communication between the OIE and its RLs. A lack of transparency about a significant disease event can

  16. A Stationary Reference Frame Grid Synchronization System for Three-Phase Grid-Connected Power Converters Under Adverse Grid Conditions

    DEFF Research Database (Denmark)

    Rodríguez, P.; Luna, A.; Muñoz-Aguilar, R. S.

    2012-01-01

    synchronization method for three-phase three-wire networks, namely dual second-order generalized integrator (SOGI) frequency-locked loop. The method is based on two adaptive filters, implemented by using a SOGI on the stationary αβ reference frame, and it is able to perform an excellent estimation......Grid synchronization algorithms are of great importance in the control of grid-connected power converters, as fast and accurate detection of the grid voltage parameters is crucial in order to implement stable control strategies under generic grid conditions. This paper presents a new grid...

  17. Ultrasound-guided epidural anesthesia for a parturient with severe malformations of the skeletal system undergoing cesarean delivery: a case report

    Directory of Open Access Journals (Sweden)

    Luo LL

    2015-05-01

    Full Text Available LinLi Luo,* Juan Ni,* Lan Wu, Dong Luo Department of Anesthesiology, West China Second Hospital, Sichuan University, Chengdu, Sichuan, People's Republic of China  *These authors contributed equally to this work and should be considered co-first authors Abstract: Anesthetic management of patients with preexisting diseases is challenging and individualized approaches need to be determined based on patients' complications. We report here a case of ultrasound-guided epidural anesthesia in combination with low-dose ketamine during cesarean delivery on a parturient with severe malformations of the skeletal system and airway problems. The ultrasound-guided epidural anesthesia was performed in the L1–L2 space, followed by an intravenous administration of ketamine (0.5 mg/kg for sedation and analgesia. Satisfactory anesthesia was provided to the patient and spontaneous ventilation was maintained during the surgery. The mother and the baby were discharged 5 days after surgery, no complications were reported for either of them. Our work demonstrated that an ultrasound-guided epidural anesthesia combined with low-dose ketamine can be used to successfully maintain spontaneous ventilation and provide effective analgesia during surgery and reduce the risk of postoperative anesthesia-related pulmonary infection. Keywords: anesthesia, regional, cesarean delivery, ketamine, ultrasound-guided

  18. Intrafractional setup errors in patients undergoing non-invasive fixation using an immobilization system during hypofractionated stereotactic radiotherapy for lung tumors

    International Nuclear Information System (INIS)

    Watanabe, Meguru; Onishi, Hiroshi; Kuriyama, Kengo

    2013-01-01

    Intrafractional setup errors during hypofractionated stereotactic radiotherapy (SRT) were investigated on the patient under voluntary breath-holding conditions with non-invasive immobilization on the CT-linac treatment table. A total of 30 patients with primary and metastatic lung tumors were treated with the hypofractionated SRT with a total dose of 48-60 Gy with four treatment fractions. The patient was placed supine and stabilized on the table with non-invasive patient fixation. Intrafractional setup errors in Right/Left (R.L.), Posterior/Anterior (P.A.), and Inferior/Superior (I.S.) dimensions were analyzed with pre- and post-irradiation CT images. The means and one standard deviation of the intrafractional errors were 0.9±0.7 mm (R.L.), 0.9±0.7 mm (P.A.) and 0.5±1.0 mm (I.S.). Setup errors in each session of the treatment demonstrated no statistically significant difference in the mean value between any two sessions. The frequency within 3 mm displacement was 98% in R.L., 98% in P.A. and 97% in I.S. directions. SRT under the non-invasive patient fixation immobilization system with a comparatively loose vacuum pillow demonstrated satisfactory reproducibility of minimal setup errors with voluntary breath-holding conditions that required a small internal margin. (author)

  19. Coagulation profile in patients undergoing video-assisted thoracoscopic lobectomy

    DEFF Research Database (Denmark)

    Christensen, Thomas Decker; Vad, Henrik; Pedersen, Søren

    2017-01-01

    -, and the first two days postoperatively by standard coagulation blood test, thromboelastometry (ROTEM®) and thrombin generation. Results: Patients undergoing potential curative surgery for lung cancer were not hypercoagulable preoperatively. There was no statistically significant difference in the majority......Background: Knowledge about the impact of Low-Molecular-Weight Heparin (LMWH) on the coagulation system in patients undergoing minimal invasive lung cancer surgery is sparse. The aim of this study was to assess the effect of LMWH on the coagulation system in patients undergoing Video......-Assisted Thoracoscopic Surgery (VATS) lobectomy for primary lung cancer. Methods: Sixty-three patients diagnosed with primary lung cancer undergoing VATS lobectomy were randomized to either subcutaneous injection with dalteparin (Fragmin®) 5000 IE once daily or no intervention. Coagulation was assessed pre-, peri...

  20. NASA/NBS (National Aeronautics and Space Administration/National Bureau of Standards) standard reference model for telerobot control system architecture (NASREM)

    Science.gov (United States)

    Albus, James S.; Mccain, Harry G.; Lumia, Ronald

    1989-01-01

    The document describes the NASA Standard Reference Model (NASREM) Architecture for the Space Station Telerobot Control System. It defines the functional requirements and high level specifications of the control system for the NASA space Station document for the functional specification, and a guideline for the development of the control system architecture, of the 10C Flight Telerobot Servicer. The NASREM telerobot control system architecture defines a set of standard modules and interfaces which facilitates software design, development, validation, and test, and make possible the integration of telerobotics software from a wide variety of sources. Standard interfaces also provide the software hooks necessary to incrementally upgrade future Flight Telerobot Systems as new capabilities develop in computer science, robotics, and autonomous system control.

  1. Global References, Local Translation: Adaptation of the Bologna Process Degree Structure and Credit System at Universities in Cameroon

    Science.gov (United States)

    Eta, Elizabeth Agbor; Vubo, Emmanuel Yenshu

    2016-01-01

    This article uses temporal comparison and thematic analytical approaches to analyse text documents and interviews, examining the adaptation of the Bologna Process degree structure and credit system in two sub-systems of education in Cameroon: the Anglo-Saxon and the French systems. The central aim is to verify whether such adaptation has replaced,…

  2. Electrical engineer's reference book

    CERN Document Server

    Laughton, M A

    1985-01-01

    Electrical Engineer's Reference Book, Fourteenth Edition focuses on electrical engineering. The book first discusses units, mathematics, and physical quantities, including the international unit system, physical properties, and electricity. The text also looks at network and control systems analysis. The book examines materials used in electrical engineering. Topics include conducting materials, superconductors, silicon, insulating materials, electrical steels, and soft irons and relay steels. The text underscores electrical metrology and instrumentation, steam-generating plants, turbines

  3. Reference to the Safety Engineering Undergraduate Courses to Improve the Subjects and Contents of the Certified Safety Engineer Qualification and Examination System of China

    OpenAIRE

    Haibin Qiu; Shanghong Shi; Tingdi Zhao; Yiwei Qiao; Jiangshi Zhang

    2013-01-01

    The aim of this paper is to recommend that the subjects and contents of certified safety engineers use safety engineering undergraduate curriculum system for reference. Human resources play an important role in accident prevention and loss control. Education on safety engineering develops quickly in China. Moreover, the State Administration of Work Safety and the National Human Resources and Social Security Ministry have implemented a certified safety engineer qualification and examination sy...

  4. Adaptation of penelope Monte Carlo code system to the absorbed dose metrology: characterization of high energy photon beams and calculations of reference dosimeter correction factors

    International Nuclear Information System (INIS)

    Mazurier, J.

    1999-01-01

    This thesis has been performed in the framework of national reference setting-up for absorbed dose in water and high energy photon beam provided with the SATURNE-43 medical accelerator of the BNM-LPRI (acronym for National Bureau of Metrology and Primary standard laboratory of ionising radiation). The aim of this work has been to develop and validate different user codes, based on PENELOPE Monte Carlo code system, to determine the photon beam characteristics and calculate the correction factors of reference dosimeters such as Fricke dosimeters and graphite calorimeter. In the first step, the developed user codes have permitted the influence study of different components constituting the irradiation head. Variance reduction techniques have been used to reduce the calculation time. The phase space has been calculated for 6, 12 and 25 MV at the output surface level of the accelerator head, then used for calculating energy spectra and dose distributions in the reference water phantom. Results obtained have been compared with experimental measurements. The second step has been devoted to develop an user code allowing calculation correction factors associated with both BNM-LPRI's graphite and Fricke dosimeters thanks to a correlated sampling method starting with energy spectra obtained in the first step. Then the calculated correction factors have been compared with experimental and calculated results obtained with the Monte Carlo EGS4 code system. The good agreement, between experimental and calculated results, leads to validate simulations performed with the PENELOPE code system. (author)

  5. Development of a reference system and a methodology for the calibration of ophthalmic applicators utilized in brachytherapy

    International Nuclear Information System (INIS)

    Oliveira, Mercia Liane de

    2005-01-01

    90 Sr+ 90 Y beta radiation sources are widely utilized in brachytherapy, in the treatment of superficial lesions of eyes and skin. According to international recommendations, these applicators should be specified in terms of the absorbed dose rate to water at the reference point (1 mm from the source surface, along its axis of symmetry). Two mini-extrapolation chambers were developed with adequate geometrical characteristics for the dosimetry of plane and concave 90 Sr+ 90 Y sources. These chambers have 3.0 cm of outer diameter and 11.3 cm of length. Aluminized polyester foils are used as entrance windows, and the collecting electrodes were made of graphited polymethylmethacrylate. The mini-chambers were tested in 90 Sr+ 90 Y radiation beams from a beta check source and plane and concave ophthalmic applicators. All results obtained show the usefulness of these chambers as reference primary standards for the calibration of 90 Sr+ 90 Y applicators. The previous calibration of the mini-chambers in relation to a standard ionization chamber or to a standard beta source is unnecessary. The minichamber with plane window showed utility for low energy X-rays too. In order to establish an alternative method for the calibration of beta radiation sources, different thermoluminescent materials were tested: LiF, CaF 2 :Mn, CaF 2 :Dy and CaS0 4 :Dy. For their characterization, the response reproducibility, calibration curves, TL response as a function of the source-detector distance, transmission factors and the linearity of the sample response were determined. The calibration procedures of ophthalmic applicators were established utilizing the ionometric technique and thermoluminescence dosimetry. (author)

  6. Moving Reference to the Web.

    Science.gov (United States)

    McGlamery, Susan; Coffman, Steve

    2000-01-01

    Explores the possibility of using Web contact center software to offer reference assistance to remote users. Discusses a project by the Metropolitan Cooperative Library System/Santiago Library System consortium to test contact center software and to develop a virtual reference network. (Author/LRW)

  7. Reference costs of electricity

    International Nuclear Information System (INIS)

    Terraz, N.

    1997-01-01

    The calculation of electric power production reference costs is used in France, even in the present case of over-capacity, for comparing the relative interest of the various means of power generation (nuclear plants, coal plants, hydroelectricity, gas combined cycles, etc.) and as an aid for future investment decisions. Reference costs show a sharp decrease between 1993 and 1997 due to advancements in nuclear plant operating ability and fossil fuel price decrease. Actuarial rates, plant service life, fuel costs and exchange rates are important parameters. The various costs from the research stage to the waste processing stages are discussed and the reference costs of the various power generation systems are presented and compared together with their competitiveness; the future of wind energy and cogeneration and the prospective of the renewal of nuclear plants at the 2010 horizon are also addressed

  8. Setting reference targets

    International Nuclear Information System (INIS)

    Ruland, R.E.

    1997-04-01

    Reference Targets are used to represent virtual quantities like the magnetic axis of a magnet or the definition of a coordinate system. To explain the function of reference targets in the sequence of the alignment process, this paper will first briefly discuss the geometry of the trajectory design space and of the surveying space, then continue with an overview of a typical alignment process. This is followed by a discussion on magnet fiducialization. While the magnetic measurement methods to determine the magnetic centerline are only listed (they will be discussed in detail in a subsequent talk), emphasis is given to the optical/mechanical methods and to the task of transferring the centerline position to reference targets

  9. A Novel Robust H∞ Filter Based on Krein Space Theory in the SINS/CNS Attitude Reference System

    Directory of Open Access Journals (Sweden)

    Fei Yu

    2016-03-01

    Full Text Available Owing to their numerous merits, such as compact, autonomous and independence, the strapdown inertial navigation system (SINS and celestial navigation system (CNS can be used in marine applications. What is more, due to the complementary navigation information obtained from two different kinds of sensors, the accuracy of the SINS/CNS integrated navigation system can be enhanced availably. Thus, the SINS/CNS system is widely used in the marine navigation field. However, the CNS is easily interfered with by the surroundings, which will lead to the output being discontinuous. Thus, the uncertainty problem caused by the lost measurement will reduce the system accuracy. In this paper, a robust H∞ filter based on the Krein space theory is proposed. The Krein space theory is introduced firstly, and then, the linear state and observation models of the SINS/CNS integrated navigation system are established reasonably. By taking the uncertainty problem into account, in this paper, a new robust H∞ filter is proposed to improve the robustness of the integrated system. At last, this new robust filter based on the Krein space theory is estimated by numerical simulations and actual experiments. Additionally, the simulation and experiment results and analysis show that the attitude errors can be reduced by utilizing the proposed robust filter effectively when the measurements are missing discontinuous. Compared to the traditional Kalman filter (KF method, the accuracy of the SINS/CNS integrated system is improved, verifying the robustness and the availability of the proposed robust H∞ filter.

  10. Sustainable management of peat swamp forest of Sarawak with special reference to ramin (Gonystylus bancanus); development of a monitoring system

    NARCIS (Netherlands)

    Wijdeven, S.M.J.; Meer, van der P.J.; Chai, F.Y.C.; Tan, S.; Mohizah, M.; Liam, D.

    2004-01-01

    Peat swamp forests in Sarawak are valuable in terms of timber and biodiversity, but heavily degraded. In order to assess the current status, potential developments and possible management interventions, an adequate monitoring system is necessary. In this study a new monitoring system is proposed,

  11. Program reference schedule baseline

    International Nuclear Information System (INIS)

    1986-07-01

    This Program Reference Schedule Baseline (PRSB) provides the baseline Program-level milestones and associated schedules for the Civilian Radioactive Waste Management Program. It integrates all Program-level schedule-related activities. This schedule baseline will be used by the Director, Office of Civilian Radioactive Waste Management (OCRWM), and his staff to monitor compliance with Program objectives. Chapter 1 includes brief discussions concerning the relationship of the PRSB to the Program Reference Cost Baseline (PRCB), the Mission Plan, the Project Decision Schedule, the Total System Life Cycle Cost report, the Program Management Information System report, the Program Milestone Review, annual budget preparation, and system element plans. Chapter 2 includes the identification of all Level 0, or Program-level, milestones, while Chapter 3 presents and discusses the critical path schedules that correspond to those Level 0 milestones

  12. A comparative study of ammonia energy systems as a future energy carrier, with particular reference to vehicle use in Japan

    International Nuclear Information System (INIS)

    Miura, Daisuke; Tezuka, Tetsuo

    2014-01-01

    The choice of secondary energy carriers, such as electricity, hydrogen and ammonia, influences not only economic and environmental performances but also the reliability of an entire energy system. This article focuses on ammonia because of its excellent property in energy storage, and assesses the relative advantages of several ammonia energy systems for vehicle use in Japan by estimating energy efficiency, CO 2 emissions, and the supply cost of several ammonia energy paths, which are then compared with alternative paths using different energy carriers including hydrogen and electricity. The article also discusses inherent merits and challenges of ammonia energy systems and identifies directions for future research and development. Using ammonia as an energy carrier was demonstrated to be competitive in terms of efficiency, CO 2 emissions and supply cost for energy systems requiring fairly large numbers of storage days. This assessment shows that the use of ammonia in an energy system can improve the continuity of the energy supply in a country or region with insecurity of supply. On the other hand, we argue that further technical improvements and cost reduction associated with both conventional and unconventional ammonia production is imperative for using ammonia in a normal energy system. - Highlights: • We assess merits of energy supply systems using ammonia as an energy carrier. • Comparison with hydrogen or electricity-based energy systems was carried out. • We find ammonia is competitive when requiring large numbers of storage days. • The use of ammonia in energy systems can improve the continuity of energy supply. • Technical improvements are needed to make ammonia attractive in normal systems

  13. Systemic Assessment of Patients Undergoing Dental Implant ...

    African Journals Online (AJOL)

    These days, dental implants are becoming routinely used as a treatment option for rehabilitation of lost teeth. Conventionally, it is only after the completion of bone healing that the dental implants are loaded into the bone. Bone healing time is approximately 3 months and. 6 months for the mandible and maxilla, respectively.

  14. The variability of inner ear orientation in saurischian dinosaurs: testing the use of semicircular canals as a reference system for comparative anatomy

    Directory of Open Access Journals (Sweden)

    Jesús Marugán-Lobón

    2013-08-01

    Full Text Available The vestibular system of the inner ear houses three semicircular canals—oriented on three nearly-orthogonal planes—that respond to angular acceleration stimuli. In recent years, the orientation of the lateral semicircular canal (LSC has been regularly used to determine skull orientations for comparative purposes in studies of non-avian dinosaurs. Such orientations have been inferred based on fixing the LSC to a common set of coordinates (parallel to the Earth’s horizon, given that the orientation to gravity of this sensory system is assumed constant among taxa. Under this assumption, the LSC is used as a baseline (a reference system both to estimate how the animals held their heads and to describe craniofacial variation among dinosaurs. However, the available data in living birds (extant saurischian dinosaurs suggests that the orientation of the LSC in non-avian saurischian dinosaurs could have been very variable and taxon-specific. If such were the case, using the LSC as a comparative reference system would cause inappropriate visual perceptions of craniofacial organization, leading to significant descriptive inconsistencies among taxa. Here, we used Procrustes methods (Geometric Morphometrics, a suite of analytical tools that compares morphology on the basis of shared landmark homology, to show that the variability of LSC relative to skull landmarks is large (ca. 50° and likely unpredictable, thus making it an inconsistent reference system for comparing and describing the skulls of saurischian (sauropodomorph and theropod dinosaurs. In light of our results, the lateral semicircular canal is an inconsistent baseline for comparative studies of craniofacial morphology in dinosaurs.

  15. Evaluation of the PREVI® Isola automated seeder system compared to reference manual inoculation for antibiotic susceptibility testing by the disk diffusion method.

    Science.gov (United States)

    Le Page, S; van Belkum, A; Fulchiron, C; Huguet, R; Raoult, D; Rolain, J-M

    2015-09-01

    The disk diffusion (DD) method remains the most popular manual technique for antibiotic susceptibility testing (AST) in clinical microbiology laboratories. This is because of its simplicity, reproducibility, and limited cost compared to (automated) microdilution systems, which are usually less sensitive at detecting certain important mechanisms of resistance. Here, we evaluate the PREVI® Isola automated seeder system using a new protocol for spreading bacterial suspensions (eight deposits of calibrated inocula of bacteria, followed by two rounds of rotation) in comparison with manual DD reference testing on a large series of clinical and reference strains. The average time required for seeding one agar plate for DD with this new protocol was 51 s per plate, i.e., 70 agar plates/h. Reproducibility and repeatability was assessed on three reference and three randomly chosen clinical strains, as usually requested by the European Committee on Antimicrobial Susceptibility Testing (EUCAST), and was excellent compared to the manual method. The standard deviations of zones of growth inhibition showed no statistical discrimination. The correlation between the two methods, assessed using 294 clinical isolates and a panel of six antibiotics (n = 3,528 zones of growth inhibition measured), was excellent, with a correlation coefficient of 0.977. The new PREVI® Isola protocol adapted for DD had a sensitivity of 99 % and a specificity of 100 % compared to the manual technique for interpreting DD as recommended by the EUCAST.

  16. The Healthcare Administrator's Desk Reference: A Managed Care and Health Care Contracting Dictionary for the Military Health System

    National Research Council Canada - National Science Library

    Korody-Colwell, Carol

    1998-01-01

    .... Specifically, a thorough knowledge of the language, terminology, and acronyms is fundamental to understanding today s health care delivery processes both in the civilian sector and the military health system...

  17. Completed Gravity Probe B Undergoes Thermal Vacuum Testing

    Science.gov (United States)

    2000-01-01

    The Gravity Probe B (GP-B) is the relativity experiment developed at Stanford University to test two extraordinary predictions of Albert Einstein's general theory of relativity. The experiment will measure, very precisely, the expected tiny changes in the direction of the spin axes of four gyroscopes contained in an Earth-orbiting satellite at a 400-mile altitude. So free are the gyroscopes from disturbance that they will provide an almost perfect space-time reference system. They will measure how space and time are very slightly warped by the presence of the Earth, and, more profoundly, how the Earth's rotation very slightly drags space-time around with it. These effects, though small for the Earth, have far-reaching implications for the nature of matter and the structure of the Universe. In this photograph, the completed space vehicle is undergoing thermal vacuum environment testing. GP-B is among the most thoroughly researched programs ever undertaken by NASA. This is the story of a scientific quest in which physicists and engineers have collaborated closely over many years. Inspired by their quest, they have invented a whole range of technologies that are already enlivening other branches of science and engineering. Launched April 20, 2004 , the GP-B program was managed for NASA by the Marshall Space Flight Center. Development of the GP-B is the responsibility of Stanford University along with major subcontractor Lockheed Martin Corporation. (Image credit to Russ Underwood, Lockheed Martin Corporation.)

  18. A coarse-graining approach for molecular simulation that retains the dynamics of the all-atom reference system by implementing hydrodynamic interactions

    Energy Technology Data Exchange (ETDEWEB)

    Markutsya, Sergiy [Ames Laboratory, Iowa State University, Ames, Iowa 50011 (United States); Lamm, Monica H., E-mail: mhlamm@iastate.edu [Ames Laboratory, Iowa State University, Ames, Iowa 50011 (United States); Department of Chemical and Biological Engineering, Iowa State University, Ames, Iowa 50011 (United States)

    2014-11-07

    We report on a new approach for deriving coarse-grained intermolecular forces that retains the frictional contribution that is often discarded by conventional coarse-graining methods. The approach is tested for water and an aqueous glucose solution, and the results from the new implementation for coarse-grained molecular dynamics simulation show remarkable agreement with the dynamics obtained from reference all-atom simulations. The agreement between the structural properties observed in the coarse-grained and all-atom simulations is also preserved. We discuss how this approach may be applied broadly to any existing coarse-graining method where the coarse-grained models are rigorously derived from all-atom reference systems.

  19. A coarse-graining approach for molecular simulation that retains the dynamics of the all-atom reference system by implementing hydrodynamic interactions

    International Nuclear Information System (INIS)

    Markutsya, Sergiy; Lamm, Monica H.

    2014-01-01

    We report on a new approach for deriving coarse-grained intermolecular forces that retains the frictional contribution that is often discarded by conventional coarse-graining methods. The approach is tested for water and an aqueous glucose solution, and the results from the new implementation for coarse-grained molecular dynamics simulation show remarkable agreement with the dynamics obtained from reference all-atom simulations. The agreement between the structural properties observed in the coarse-grained and all-atom simulations is also preserved. We discuss how this approach may be applied broadly to any existing coarse-graining method where the coarse-grained models are rigorously derived from all-atom reference systems

  20. Systems Analysis Programs for Hands-on Integrated Reliability Evaluations (SAPHIRE), Version 5.0: Models and Results Database (MAR-D) reference manual. Volume 8

    International Nuclear Information System (INIS)

    Russell, K.D.; Skinner, N.L.

    1994-07-01

    The Systems Analysis Programs for Hands-on Integrated Reliability Evaluations (SAPHIRE) refers to a set of several microcomputer programs that were developed to create and analyze probabilistic risk assessments (PRAs), primarily for nuclear power plants. The primary function of MAR-D is to create a data repository for completed PRAs and Individual Plant Examinations (IPEs) by providing input, conversion, and output capabilities for data used by IRRAS, SARA, SETS, and FRANTIC software. As probabilistic risk assessments and individual plant examinations are submitted to the NRC for review, MAR-D can be used to convert the models and results from the study for use with IRRAS and SARA. Then, these data can be easily accessed by future studies and will be in a form that will enhance the analysis process. This reference manual provides an overview of the functions available within MAR-D and step-by-step operating instructions

  1. Balinese Frame of Reference

    Directory of Open Access Journals (Sweden)

    I Nyoman Aryawibawa

    2016-04-01

    Full Text Available Abstract: Balinese Frame of Reference. Wassmann and Dasen (1998 did a study on the acquisition of Balinese frames of reference. They pointed out that, in addition to the dominant use of absolute system, the use of relative system was also observed. This article aims at verifying Wassmann and Dasen’ study. Employing monolingual Balinese speakers and using linguistic and non-linguistic tasks, Aryawibawa (2010, 2012, 2015 showed that Balinese subjects used an absolute system dominantly in responding the two tasks, e.g. The man is north/south/east/west of the car. Unlike Wassmann and Dasen’s results, no relative system was used by the subjects in solving the tasks. Instead of the relative system, an intrinsic system was also observed in this study, even though it was unfrequent. The article concludes that the absolute system was dominantly employed by Balinese speakers in describing spatial relations in Balinese. The use of the system seems to affect their cognitive functions.

  2. Structural lesions detected by magnetic resonance imaging in the spine of patients with spondyloarthritis - definitions, assessment system, and reference image set

    DEFF Research Database (Denmark)

    Østergaard, Mikkel; Maksymowych, Walter P; Pedersen, Susanne J

    2009-01-01

    are assessed at each vertebral endplate at all 23 spinal levels from C2/3 to L5/S1, whereas facet joint lesions are to be assessed by segmental level (cervical, thoracic, and lumbar). CONCLUSION: An anatomy-based set of definitions and an assessment system for structural lesions in the spine of patients......OBJECTIVE: There is no reliable and sensitive magnetic resonance imaging (MRI) assessment system for structural lesions in patients with spondyloarthritis (SpA). We sought to develop and illustrate a detailed anatomy-based set of MRI definitions and an assessment system for structural lesions...... in the spine of patients with SpA. METHODS: MRI definitions of different structural ("chronic") lesions at various anatomical locations in the spine, and an accompanying assessment system, were agreed by consensus within the Canada-Denmark MRI working group. Subsequently, a reference image set...

  3. Modelling the heat dynamics of a monitored Test Reference Environment for Building Integrated Photovoltaic systems using stochastic differential equations

    DEFF Research Database (Denmark)

    Lodi, C.; Bacher, Peder; Cipriano, J.

    2012-01-01

    reduce the ventilation thermal losses of the building by pre-heating the fresh air. Furthermore, by decreasing PV module temperature, the ventilation air heat extraction can simultaneously increase electrical and thermal energy production of the building. A correct prediction of the PV module temperature...... and heat transfer coefficients is fundamental in order to improve the thermo-electrical production.The considered grey-box models are composed of a set of continuous time stochastic differential equations, holding the physical description of the system, combined with a set of discrete time measurement......This paper deals with grey-box modelling of the energy transfer of a double skin Building Integrated Photovoltaic (BIPV) system. Grey-box models are based on a combination of prior physical knowledge and statistics, which enable identification of the unknown parameters in the system and accurate...

  4. Methods for Aiding Height Determination in Pseudolite-Based Reference Systems Using Batch Least-Squares Estimation

    Science.gov (United States)

    2006-03-01

    LocataLite Test Examples. LocataLites have been used in several experimental trials as pilot studies of the system. 1.7.5.1 BlueScope Steel. In this pilot...study, [2], the Locata system is shown to give centimeter level relative positioning precision in a severe multipath en- vironment. The BlueScope ...Using Locata: A pilot study at BlueScope Steel.” Proceedings of the 2004 Annual Meeting of the U.S. Institute of Navigation. Dayton, OH, June 2004. 3

  5. Importance of quality aspects of GP care among ethnic minorities: role of cultural attitudes, language and healthcare system of reference.

    NARCIS (Netherlands)

    Lamkaddem, M.; Spreeuwenberg, P.M.; Devillé, W.L.; Foets, M.M.; Groenewegen, P.P.

    2012-01-01

    Aims: This study examines the mechanisms responsible for ethnic differences in perceived quality of care in the Netherlands. The specific role of cultural attitudes, language proficiency, and the health system in the country of origin was examined, taking socio-demographic characteristics into

  6. Food allergens and mucosal immune systems with special reference to recognition of food allergens by gut-associated lymphoid tissue

    Directory of Open Access Journals (Sweden)

    Shuichi Kaminogawa

    1999-01-01

    Full Text Available Food allergy, triggered by an aberrant immune response elicited by orally ingested food allergens, is generated through a complicated mechanism because the allergen interacts with the mucosal immune system (the gut- associated lymphoid tissue, GALT and the resulting immune response affects the generation of allergy. This review will describe the process by which antigens or allergens are recognized by the GALT and the characteristic immune responses induced thereafter. Orally administered antigens induce distinct immune responses in the Peyer's patches, lamina propria and the intestinal epithelium. In addition to these local immune responses in the gut, ingested antigens are known to affect systemic immunity. These may induce a suppressed state of systemic immune responsiveness, which is called oral tolerance, or in some cases they may elicit a systemic IgE antibody response which may lead to allergic reactions. Information on the regions on food allergens recognized by T cells and IgE antibodies is important in understanding the fates of food allergens after being recognized by the GALT. The structure of T and B cell epitopes on food allergens and the possibility of modulation of allergic reactions by amino-acid substituted analogs of allergen- derived peptides will also be discussed.

  7. 1-GWh diurnal load-leveling superconducting magnetic energy storage system reference design. Appendix A: energy storage coil and superconductor

    International Nuclear Information System (INIS)

    Schermer, R.I.

    1979-09-01

    The technical aspects of a 1-GWh Superconducting Magnetic Energy Storage (SMES) coil for use as a diurnal load-leveling device in an electric utility system are presented. The superconductor for the coil is analyzed, and costs for the entire coil are developed

  8. Prophylaxis of acute radiation dermatitis with an innovative FDA-approved two-step skin care system in a patient with head and neck cancer undergoing a platin-based radiochemotherapy: a case report and review of the literature.

    Science.gov (United States)

    Häfner, M F; Fetzner, L; Hassel, J C; Debus, J; Potthoff, K

    2013-01-01

    Radiodermatitis is a very common side effect in cancer treatment often leading to therapy delays and diminution of the patients' health state and quality of life. Despite a wide range of supportive strategies, radiodermatitis is still a major problem necessitating further improvements in prevention and treatment. Lactokine is a milk-based protein shown to assist in the reduction of skin redness. The treatment is a unique FDA-approved skin care system (R1 and R2). In this case presentation we describe the prophylactic use of R1 and R2 in a 63-year-old, female patient with a squamous cell carcinoma of the hypopharynx undergoing a platin-based chemoradiation. The application was feasible and safe and the patient developed only a slight radiodermatitis. To our knowledge this is the first report in the literature on the prophylactic use of R1 and R2. Further evidence will be provided by a prospective, clinical trial we have launched (CREAM-1; study registration in ISRCTN Registry: ISRCTN87302591). We also review the literature to give an overview about common strategies in the management of radiodermatitis.

  9. Analysis of Properties of Reflectance Reference Targets for Permanent Radiometric Test Sites of High Resolution Airborne Imaging Systems

    Directory of Open Access Journals (Sweden)

    Eero Ahokas

    2010-08-01

    Full Text Available Reliable and optimal exploitation of rapidly developing airborne imaging methods requires geometric and radiometric quality assurance of production systems in operational conditions. Permanent test sites are the most promising approach for cost-efficient performance assessment. Optimal construction of permanent radiometric test sites for high resolution airborne imaging systems is an unresolved issue. The objective of this study was to assess the performance of commercially available gravels and painted and unpainted concrete targets for permanent, open-air radiometric test sites under sub-optimal climate conditions in Southern Finland. The reflectance spectrum and reflectance anisotropy and their stability were characterized during the summer of 2009. The management of reflectance anisotropy and stability were shown to be the key issues for better than 5% reflectance accuracy.

  10. Development of a reference method and sampling system for continuous monitoring of environmental HT and HTO concentration in the air

    International Nuclear Information System (INIS)

    Uchrin, G.

    1992-06-01

    A differential sampling system to monitor environmental Tritiated Water Vapour (HT) and Tritiated Hydrogen Gas (HTO) concentrations in the atmosphere was developed and tested. The sampler consists of an aerosol filter, diaphragm pump, absorption trap for HTO (molecular sieve), supply of H 2 carrier (electrolysis unit), conversion trap for HT (Pd-impregnated molecular sieve), flow meter and gas meter. The sampler operates with a flow rate between 30 and 80 1/h, with a typical sampling period of one week. Vacuum desorption at high temperature is used to extract the HTO collected in the absorption and conversion traps. Tritium analysis is carried out using liquid scintillation spectrometry or gas proportional counting. The sampler is equipped with built-in safety systems and can operate in remote places. Refs, figs and tabs

  11. The PMA Catalogue as a realization of the extragalactic reference system in optical and near infrared wavelengths

    Science.gov (United States)

    Akhmetov, Volodymyr S.; Fedorov, Peter N.; Velichko, Anna B.

    2018-04-01

    We combined the data from the Gaia DR1 and Two-Micron All Sky Survey (2MASS) catalogues in order to derive the absolute proper motions more than 420 million stars distributed all over the sky in the stellar magnitude range 8 mag 2MASS catalogue objects, the 2-dimensional median filter was used. The PMA system of proper motion has been obtained by direct link to 1.6 millions extragalactic sources. The short analysis of the absolute proper motion of the PMA stars Catalogue is presented in this work. From a comparison of this data with same stars from the TGAS, UCAC4 and PPMXL catalogues, the equatorial components of the mutual rotation vector of these coordinate systems are determined.

  12. Four-year prospective study of STAPH-IDENT system and conventional method for reference identification of Staphylococcus, Stomatococcus, and Micrococcus spp..

    Science.gov (United States)

    Rhoden, D L; Miller, J M

    1995-01-01

    A 4-year prospective study compared the accuracy of the STAPH-IDENT system (bioMérieux Vitek, Inc., Hazelwood, Mo.) with that of the reference procedure of the Centers for Disease Control and Prevention for the identification of Staphylococcus species, Stomatococcus mucilaginosus, and Micrococcus species. The study compared the results from 1,106 cultures (500 eye cultures, 217 strains submitted for reference identification, and 389 known stock strains) representing 21 species of the family Micrococcaceae. The overall agreement of genus and species identifications was 81.1%. The percent agreement for the five most common clinical isolates was as follows: Staphylococcus epidermidis, 97.1% (517 isolates); Staphylococcus hominis, 82.5% (57 isolates); Staphylococcus aureus, 77.2% (162 isolates); Staphylococcus haemolyticus, 75.8% (61 isolates); and Staphylococcus warneri, 64.1% (39 isolates). The lowest percent agreement was with Staphylococcus cohnii (11.1%; (9 isolates). Of the 217 isolates sent to the Centers for Disease Control and Prevention for identification, 60.4% (131) were correctly identified by the STAPH-IDENT system. Of these, S. epidermidis accounted for 23.9%, S. aureus accounted for 15.6%, S. warneri accounted for 6.9%, Staphylococcus lugdunensis accounted for 6.5%, S. haemolyticus accounted for 5.5%, and S. hominis accounted for 4.1%. The STAPH-IDENT system did not perform adequately when dealing with commonly encountered organisms and is unsuitable for identifying uncommon isolates. PMID:7699074

  13. Power and gas suppliers' obligations in their relations with small companies and residential clients (reference system/specifications/good practice code model)

    International Nuclear Information System (INIS)

    2003-08-01

    This document is a project of good practice manual for the commercial relations between energy suppliers and their clients: prohibition of dishonest practices (fake, aggressive practices, joint sales, lack of information, abuse of vulnerable clients), remote sales and canvassing, pre-contractual information, minimum content of contracts (products and proposed services, tariffs, modalities and conditions of payment, meters, refusal to supply, supply disruption, commitment duration, rescinding, contract renewing, cancellation, contract transfer, modification of contracts in progress, procedure of dispute settlement), minimum content of bills (monthly bill, annual bill); contracts renewing, cancellation, transfer and modification; control and procedure of dispute settlement, disregard of the reference system. (J.S.)

  14. Quantum frames of reference

    International Nuclear Information System (INIS)

    Kaufherr, T.

    1981-01-01

    The idea that only relative variables have physical meaning came to be known as Mach's principle. Carrying over this idea to quantum theory, has led to the consideration of finite mass, macroscopic reference frames, relative to which all physical quantities are measured. During the process of measurement, a finite mass observer receives a kickback, and this reaction of the measuring device is not negligible in quantum theory because of the quantization of the action. Hence, the observer himself has to be included in the system that is being considered. Using this as the starting point, a number of thought experiments involving finite mass observers is discussed which have quantum uncertainties in their time or in their position. These thought experiments serve to elucidate in a qualitative way some of the difficulties involved, as well as pointing out a direction to take in seeking solutions to them. When the discussion is extended to include more than one observer, the question of the covariance of the theory immediately arises. Because none of the frames of reference should be preferred, the theory should be covariant. This demand expresses an equivalence principle which here is extended to include reference frames which are in quantum uncertainties relative to each other. Formulating the problem in terms of canonical variables, the ensueing free Hamiltonian contains vector and scalar potentials which represent the kick that the reference frame receives during measurement. These are essentially gravitational type potentials, resulting, as it were, from the extension of the equivalence principle into the quantum domain

  15. The global rock art database: developing a rock art reference model for the RADB system using the CIDOC CRM and Australian heritage examples

    Science.gov (United States)

    Haubt, R. A.

    2015-08-01

    The Rock Art Database (RADB) is a virtual organisation that aims to build a global rock art community. It brings together rock art enthusiasts and professionals from around the world in one centralized location through the deployed publicly available RADB Management System. This online platform allows users to share, manage and discuss rock art information and offers a new look at rock art data through the use of new technologies in rich media formats. Full access to the growing platform is currently only available for a selected group of users but it already links over 200 rock art projects around the globe. This paper forms a part of the larger Rock Art Database (RADB) project. It discusses the design stage of the RADB System and the development of a conceptual RADB Reference Model (RARM) that is used to inform the design of the Rock Art Database Management System. It examines the success and failure of international and national systems and uses the Australian heritage sector and Australian rock art as a test model to develop a method for the RADB System design. The system aims to help improve rock art management by introducing the CIDOC CRM in conjunction with a rock art specific domain model. It seeks to improve data compatibility and data sharing to help with the integration of a variety of resources to create the global Rock Art Database Management System.

  16. Development of a Korean Reference disposal System(A-KRS) for the HLW from Advanced Fuel Cycles

    International Nuclear Information System (INIS)

    Choi, Heui Joo; Choi, J. W.; Lee, J. Y.

    2010-04-01

    A database program for analyzing the characteristics of spent fuels was developed, and A-SOURCE program for characterizing the source term of HLW from advanced fuel cycles. A new technique for developing a copper canister by introducing a cold spray technique was developed, which could reduce the amount of copper. Also, to enhance the performance of A-KRS, two kinds of properties, thermal performance and iodine adsorption, were studied successfully. A complex geological disposal system which can accommodate all the HLW (CANDU and HANARO spent fuels, HLW from pyro-processing of PWR spent fuels, decommissioning wastes) was developed, and a conceptual design was carried out. Operational safety assessment system was constructed for the long-term management of A-KRS. Three representative accidental cases were analyzed, and the probabilistic safety assessment was adopted as a methodology for the safety evaluation of A-KRS operation. A national program was proposed to support the HLW national policy on the HLW management. A roadmap for HLW management was proposed based on the optimum timing of disposal

  17. An overview of reference user services during the ATDRSS (Advanced Tracking and Data Relay Satellite System) era

    Science.gov (United States)

    Weinberg, Aaron

    1989-01-01

    The Tracking and Data Relay Satellite System (TDRSS) is an integral part of the overall NASA Space Network (SN) that will continue to evolve into the 1990's. Projections for the first decade of the 21st century indicate the need for an SN evolution that must accommodate growth int he LEO user population and must further support the introduction of new/improved user services. A central ingredient of this evolution is an Advanced TDRSS (ATDRSS) follow-on to the current TDRSS that must initiate operations by the late 1990's in a manner that permits an orderly transition from the TDRSS to the ATDRSS era. An SN/ATDRSS architectural and operational concept that will satisfy the above goals is being developed. To this date, an SN/ATDRSS baseline concept was established that provides users with an end-to-end data transport (ENDAT) service. An expanded description of the baseline ENDAT concept, from the user perspective, is provided with special emphasis on the TDRSS/ATDRSS evolution. A high-level description of the end-to-end system that identifies the role of ATDRSS is presented; also included is a description of the baseline ATDRSS architecture and its relationship with the TDRSS 1996 baseline. Other key features of the ENDAT service are then expanded upon, including the multiple grades of service, and the RF telecommunications/tracking services to be available. The ATDRSS service options are described.

  18. Development of a reference liquid scintillation cocktail

    CSIR Research Space (South Africa)

    Van Wyn Gaardt, WM

    2006-02-01

    Full Text Available A reference system that would allow national laboratories to compare their activity measurements of non-gamma-emitting radionuclides at any time is currently being developed. The system requires a non-commercial reference-liquid scintillation...

  19. Electronics engineer's reference book

    CERN Document Server

    Mazda, F F

    1989-01-01

    Electronics Engineer's Reference Book, Sixth Edition is a five-part book that begins with a synopsis of mathematical and electrical techniques used in the analysis of electronic systems. Part II covers physical phenomena, such as electricity, light, and radiation, often met with in electronic systems. Part III contains chapters on basic electronic components and materials, the building blocks of any electronic design. Part IV highlights electronic circuit design and instrumentation. The last part shows the application areas of electronics such as radar and computers.

  20. Systemic infection by equid herpesvirus-1 in a Grevy's zebra stallion (Equus grevyi) with particular reference to genital pathology.

    Science.gov (United States)

    Blunden, A S; Smith, K C; Whitwell, K E; Dunn, K A

    1998-11-01

    A severe multi-systemic form of equid herpesvirus-1 infection is described in an adult zebra stallion. There was multifocal necrotizing rhinitis, marked hydrothorax and pulmonary oedema, with viral antigen expression in degenerating epithelial cells, local endothelial cells and intravascular leucocytes of the nasal mucosa and lung. Specific localization of EHV-1 infection was seen in the testes and epididymides, including infection of Leydig cells and germinal epithelium, which would have facilitated venereal shedding of virus in life. The case provided a unique opportunity to study hitherto undescribed aspects of the pathogenesis of naturally occurring EHV-1 infection in the male equine genital tract. Restriction digests of the isolate demonstrated a pattern similar to that of EHV-1 isolates previously recovered from aborted zebra and onager fetuses.

  1. The new German regulatory system of monitoring workers for intakes of radioactivity with special reference to thorium

    International Nuclear Information System (INIS)

    Henrichs, K.

    1995-01-01

    In Germany, the Association for Radiation Protection (member of IRPA) defined a new standard for the monitoring of workers occupationally exposed to radioactive material. During the last two years this draft has been accepted by the German government in the form of three directives. The purpose of our approach was the installation of a system defining clear criteria for the necessity of regular and special monitoring programs, giving directives for monitoring programs ensuring that dose assessments are as reliable as necessary with the lowest possible expenses, standardizing as far as possible the procedures of dose assessments, and guaranteeing the necessary quality standards. The most important features of these regulations will be discussed in this contribution and their application will be exemplified for the specially difficult monitoring of thorium intakes. (author). 2 figs., 2 tabs

  2. Analysis of atmospheric flow over a surface protrusion using the turbulence kinetic energy equation with reference to aeronautical operating systems

    Science.gov (United States)

    Frost, W.; Harper, W. L.

    1975-01-01

    Flow over surface obstructions can produce significantly large wind shears such that adverse flying conditions can occur for aeronautical systems (helicopters, STOL vehicles, etc.). Atmospheric flow fields resulting from a semi-elliptical surface obstruction in an otherwise horizontally homogeneous statistically stationary flow are modelled with the boundary-layer/Boussinesq-approximation of the governing equation of fluid mechanics. The turbulence kinetic energy equation is used to determine the dissipative effects of turbulent shear on the mean flow. Iso-lines of turbulence kinetic energy and turbulence intensity are plotted in the plane of the flow and highlight regions of high turbulence intensity in the stagnation zone and sharp gradients in intensity along the transition from adverse to favourable pressure gradient. Discussion of the effects of the disturbed wind field in CTOL and STOL aircraft flight path and obstruction clearance standards is given. The results indicate that closer inspection of these presently recommended standards as influenced by wind over irregular terrains is required.

  3. Reference frame for Product Configuration

    DEFF Research Database (Denmark)

    Ladeby, Klaes Rohde; Oddsson, Gudmundur Valur

    2011-01-01

    a reference frame for configuration that permits 1) a more precise understanding of a configuration system, 2) a understanding of how the configuration system relate to other systems, and 3) a definition of the basic concepts in configuration. The total configuration system, together with the definition...

  4. The Asymptotic Behavior of Particle Size Distribution Undergoing Brownian Coagulation Based on the Spline-Based Method and TEMOM Model

    Directory of Open Access Journals (Sweden)

    Qing He

    2018-01-01

    Full Text Available In this paper, the particle size distribution is reconstructed using finite moments based on a converted spline-based method, in which the number of linear system of equations to be solved reduced from 4m × 4m to (m + 3 × (m + 3 for (m + 1 nodes by using cubic spline compared to the original method. The results are verified by comparing with the reference firstly. Then coupling with the Taylor-series expansion moment method, the evolution of particle size distribution undergoing Brownian coagulation and its asymptotic behavior are investigated.

  5. Reference handbook: Level detectors

    International Nuclear Information System (INIS)

    1990-01-01

    The purpose of this handbook is to provide Rocky Flats personnel with the information necessary to understand level measurement and detection. Upon completion of this handbook you should be able to do the following: List three reasons for measuring level. Describe the basic operating principles of the sight glass. Demonstrate proper techniques for reading a sight glass. Describe the basic operating principles of a float level detector. Describe the basic operating principles of a bubbler level indicating system. Explain the differences between a wet and dry reference leg indicating system, and describe how each functions. This handbook is designed for use by experienced Rocky Flats operators to reinforce and improve their current knowledge level, and by entry-level operators to ensure that they possess a minimum level of fundamental knowledge. Level Detectors is applicable to many job classifications and can be used as a reference for classroom work or for self-study. Although this reference handbook is by no means all-encompassing, you will gain enough information about this subject area to assist you in contributing to the safe operation of Rocky Flats Plant

  6. Correction and validation of 14C chronologies in lake basins, with reference to modern hydrogeological and geochemical systems - examples

    International Nuclear Information System (INIS)

    Gibert, E.; Bergonzini, L.; Travi, Y.

    2004-01-01

    The primary question before establishing any accurate, confident timescale for palaeo-environmental reconstructions based on lacustrine sediments consists in the definition of the original signature of the TDIC (Total Dissolved Inorganic Carbon) of the lake water from which authigenic compounds are fog ned. This 'carbon' fingerprint of the TDIC may originate from: - The direct exchange with atmospheric CO 2 ; - The admixture of dead dissolved carbon (for example through the leaching of ancient carbonated rocks on the watershed brought to the lake via tributaries) implying the non-equilibrium, and then the ageing, of lake surface waters; - Hydrogeological features of the lake system, such as (i) the connection of the lake waters with extended, shallow aquifers in which the radioactive 14 C decay already occurs, or (ii) high hydraulic gradient (mountain landscape) precluding water-rock interaction at the basin scale; - Deep 14 C-free CO 2 rising along faults in volcanic/tectonic areas, labelled with specific, although wide, ranges of δ 13 C values from 0 to -9%o PDB. Previous and on-going works on lakes in key regions have highlighted that, although each lake constitute a specific case study, they can be gathered in groups representing typical cases of distortion of the 14 C cycle in lacustrine systems: - eg Lake Bangong (Western Tibet): deep CO 2 at the lake bottom, and corrections of the chronology based on the 13 C/ 14 C couple and on a regression equation defined on datings... - eg Lake Abiyata (East African Rift): ageing of the authigenic carbonates due to the mixing, at the water/sediment interface, of the lake water and the 14 C-depleted regional groundwater; - eg Lake Langano (East African Rift): deep CO 2 at the lake bottom and correction of the ageing of the lake surface water by a black-boxes model which provide a step-by-step calculation including the 14 C input of atmospheric nuclear weapon tests in the 1960's and the lake turn-over; - eg Lake Aibi

  7. A computer code for calculation of solvent-extraction separation in a multicomponent system with reference to nuclear fuel reprocessing

    International Nuclear Information System (INIS)

    Carassiti, F.; Liuzzo, G.; Morelli, A.

    1982-01-01

    Nuclear technology development pointed out the need for a new assessment of the fuel cycle back-end. Treatment and disposal of radioactive wastes arising from nuclear fuel reprocessing is known as one of the problems not yet satisfactorily solved, together with separation process of uranium and plutonium from fission products in highly irradiated fuels. Aim of this work is to present an improvement of the computer code for solvent extraction process calculation previously designed by the authors. The modeling of the extraction system has been modified by introducing a new method for calculating the distribution coefficients. The new correlations were based on deriving empirical functions for not only the apparent equilibrium constants, but also the solvation number. The mathematical model derived for calculating separation performance has been then tested for up to ten components and twelve theoretical stages with minor modifications to the convergence criteria. Suitable correlations for the calculation of the distribution coefficients of Uranium, Plutonium, Nitric Acid and fission products were constructed and used to successfully simulate several experimental conditions. (Author)

  8. A Framework Based on Reference Data with Superordinate Accuracy for the Quality Analysis of Terrestrial Laser Scanning-Based Multi-Sensor-Systems.

    Science.gov (United States)

    Stenz, Ulrich; Hartmann, Jens; Paffenholz, Jens-André; Neumann, Ingo

    2017-08-16

    Terrestrial laser scanning (TLS) is an efficient solution to collect large-scale data. The efficiency can be increased by combining TLS with additional sensors in a TLS-based multi-sensor-system (MSS). The uncertainty of scanned points is not homogenous and depends on many different influencing factors. These include the sensor properties, referencing, scan geometry (e.g., distance and angle of incidence), environmental conditions (e.g., atmospheric conditions) and the scanned object (e.g., material, color and reflectance, etc.). The paper presents methods, infrastructure and results for the validation of the suitability of TLS and TLS-based MSS. Main aspects are the backward modelling of the uncertainty on the basis of reference data (e.g., point clouds) with superordinate accuracy and the appropriation of a suitable environment/infrastructure (e.g., the calibration process of the targets for the registration of laser scanner and laser tracker data in a common coordinate system with high accuracy) In this context superordinate accuracy means that the accuracy of the acquired reference data is better by a factor of 10 than the data of the validated TLS and TLS-based MSS. These aspects play an important role in engineering geodesy, where the aimed accuracy lies in a range of a few mm or less.

  9. Methodology for assessing the safety of Hydrogen Systems: HyRAM 1.1 technical reference manual

    Energy Technology Data Exchange (ETDEWEB)

    Groth, Katrina; Hecht, Ethan; Reynolds, John Thomas; Blaylock, Myra L.; Erin E. Carrier

    2017-03-01

    The HyRAM software toolkit provides a basis for conducting quantitative risk assessment and consequence modeling for hydrogen infrastructure and transportation systems. HyRAM is designed to facilitate the use of state-of-the-art science and engineering models to conduct robust, repeatable assessments of hydrogen safety, hazards, and risk. HyRAM is envisioned as a unifying platform combining validated, analytical models of hydrogen behavior, a stan- dardized, transparent QRA approach, and engineering models and generic data for hydrogen installations. HyRAM is being developed at Sandia National Laboratories for the U. S. De- partment of Energy to increase access to technical data about hydrogen safety and to enable the use of that data to support development and revision of national and international codes and standards. This document provides a description of the methodology and models contained in the HyRAM version 1.1. HyRAM 1.1 includes generic probabilities for hydrogen equipment fail- ures, probabilistic models for the impact of heat flux on humans and structures, and computa- tionally and experimentally validated analytical and first order models of hydrogen release and flame physics. HyRAM 1.1 integrates deterministic and probabilistic models for quantifying accident scenarios, predicting physical effects, and characterizing hydrogen hazards (thermal effects from jet fires, overpressure effects from deflagrations), and assessing impact on people and structures. HyRAM is a prototype software in active development and thus the models and data may change. This report will be updated at appropriate developmental intervals.

  10. Accuracy of Referring Provider and Endoscopist Impressions of Colonoscopy Indication.

    Science.gov (United States)

    Naveed, Mariam; Clary, Meredith; Ahn, Chul; Kubiliun, Nisa; Agrawal, Deepak; Cryer, Byron; Murphy, Caitlin; Singal, Amit G

    2017-07-01

    Background: Referring provider and endoscopist impressions of colonoscopy indication are used for clinical care, reimbursement, and quality reporting decisions; however, the accuracy of these impressions is unknown. This study assessed the sensitivity, specificity, positive and negative predictive value, and overall accuracy of methods to classify colonoscopy indication, including referring provider impression, endoscopist impression, and administrative algorithm compared with gold standard chart review. Methods: We randomly sampled 400 patients undergoing a colonoscopy at a Veterans Affairs health system between January 2010 and December 2010. Referring provider and endoscopist impressions of colonoscopy indication were compared with gold-standard chart review. Indications were classified into 4 mutually exclusive categories: diagnostic, surveillance, high-risk screening, or average-risk screening. Results: Of 400 colonoscopies, 26% were performed for average-risk screening, 7% for high-risk screening, 26% for surveillance, and 41% for diagnostic indications. Accuracy of referring provider and endoscopist impressions of colonoscopy indication were 87% and 84%, respectively, which were significantly higher than that of the administrative algorithm (45%; P 90%) for determining screening (vs nonscreening) indication, but specificity of the administrative algorithm was lower (40.3%) compared with referring provider (93.7%) and endoscopist (84.0%) impressions. Accuracy of endoscopist, but not referring provider, impression was lower in patients with a family history of colon cancer than in those without (65% vs 84%; P =.001). Conclusions: Referring provider and endoscopist impressions of colonoscopy indication are both accurate and may be useful data to incorporate into algorithms classifying colonoscopy indication. Copyright © 2017 by the National Comprehensive Cancer Network.

  11. IFCC primary reference procedures for the measurement of catalytic activity concentrations of enzymes at 37 °C. Part 9: reference procedure for the measurement of catalytic concentration of alkaline phosphatase International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) Scientific Division, Committee on Reference Systems of Enzymes (C-RSE) (1)).

    Science.gov (United States)

    Schumann, Gerhard; Klauke, Rainer; Canalias, Francesca; Bossert-Reuther, Steffen; Franck, Paul F H; Gella, F-Javier; Jørgensen, Poul J; Kang, Dongchon; Lessinger, Jean-Marc; Panteghini, Mauro; Ceriotti, Ferruccio

    2011-09-01

    Abstract This paper is the ninth in a series dealing with reference procedures for the measurement of catalytic activity concentrations of enzymes at 37 °C and the certification of reference preparations. Other parts deal with: Part 1. The concept of reference procedures for the measurement of catalytic activity concentrations of enzymes; Part 2. Reference procedure for the measurement of catalytic concentration of creatine kinase; Part 3. Reference procedure for the measurement of catalytic concentration of lactate dehydrogenase; Part 4. Reference procedure for the measurement of catalytic concentration of alanine aminotransferase; Part 5. Reference procedure for the measurement of catalytic concentration of aspartate aminotransferase; Part 6. Reference procedure for the measurement of catalytic concentration of γ-glutamyltransferase; Part 7. Certification of four reference materials for the determination of enzymatic activity of γ-glutamyltransferase, lactate dehydrogenase, alanine aminotransferase and creatine kinase at 37 °C; Part 8. Reference procedure for the measurement of catalytic concentration of α-amylase. The procedure described here is derived from the previously described 30 °C IFCC reference method. Differences are tabulated and commented on in Appendix 1.

  12. Electroacoustical reference data

    CERN Document Server

    Eargle, John M

    2002-01-01

    The need for a general collection of electroacoustical reference and design data in graphical form has been felt by acousticians and engineers for some time. This type of data can otherwise only be found in a collection of handbooks. Therefore, it is the author's intention that this book serve as a single source for many electroacoustical reference and system design requirements. In form, the volume closely resembles Frank Massa's Acoustic Design Charts, a handy book dating from 1942 that has long been out of print. The basic format of Massa's book has been followed here: For each entry, graphical data are presented on the right page, while text, examples, and refer­ ences appear on the left page. In this manner, the user can solve a given problem without thumbing from one page to the next. All graphs and charts have been scaled for ease in data entry and reading. The book is divided into the following sections: A. General Acoustical Relationships. This section covers the behavior of sound transmis­ sion in...

  13. Aspects Referring Wind Energy Integration from the Power System Point of View in the Region of Southeast Europe. Study Case of Romania

    Directory of Open Access Journals (Sweden)

    Simona-Vasilica Oprea

    2018-01-01

    Full Text Available Wind energy integration is a complex target that could refer to different aspects such as: grid capacity; power system; support scheme; environmental; social issues; etc. It is probably the less predictable renewable energy sources (RES due to its high volatility being difficult to be securely integrated into the power systems. This paper will focus on the wind energy integration from the power system point of view, emphasizing the case of Romania. Before going into the Romanian case, the paper analyzes the potential benefits of the regional approach in terms of power system integration, revealing that it can bring significant advantages by reducing the required power reserves or increasing wind power plants (WPP generation. Currently, the power system integration is one of the major obstacle to large scale wind energy penetration in the region of Southeast (SE Europe with high wind energy potential. The results of our research consist in proposing a model for estimating the balancing reserves sharing at regional level, comparing regional to country-by-country approach in terms of the power reserve requirements for balancing the operation of WPP. It definitely reveals that by regional Transmission System Operators (TSO coordination; less reserves are needed; therefore, the space for RES enlarges. We also propose a model for Romanian power system that is able to calculate the installed power of WPP that could operate without considerable interruptions. Also, the model estimates the additional power reserves required for larger wind energy integration. This perspective can provide interesting insights on what should be foreseen as reasonable behavior of the policy makers and investors.

  14. Standard Reference Tables -

    Data.gov (United States)

    Department of Transportation — The Standard Reference Tables (SRT) provide consistent reference data for the various applications that support Flight Standards Service (AFS) business processes and...

  15. Verification of SAP reference models

    NARCIS (Netherlands)

    Dongen, van B.F.; Jansen-Vullers, M.H.; Aalst, van der W.M.P.; Benatallah, B.; Casati, F.

    2005-01-01

    To configure a process-aware information system (e.g., a workflow system, an ERP system), a business model needs to be transformed into an executable process model. Due to similarities in these transformations for different companies, databases with reference models, such as ARIS for MySAP, have

  16. Mechanical engineer's reference book

    CERN Document Server

    Parrish, A

    1973-01-01

    Mechanical Engineer's Reference Book: 11th Edition presents a comprehensive examination of the use of Systéme International d' Unités (SI) metrication. It discusses the effectiveness of such a system when used in the field of engineering. It addresses the basic concepts involved in thermodynamics and heat transfer. Some of the topics covered in the book are the metallurgy of iron and steel; screw threads and fasteners; hole basis and shaft basis fits; an introduction to geometrical tolerancing; mechanical working of steel; high strength alloy steels; advantages of making components as castings

  17. VBScript pocket reference

    CERN Document Server

    Lomax, Paul; Petrusha, Ron

    2008-01-01

    Microsoft's Visual Basic Scripting Edition (VBScript), a subset of Visual Basic for Applications, is a powerful language for Internet application development, where it can serve as a scripting language for server-side, client-side, and system scripting. Whether you're developing code for Active Server Pages, client-side scripts for Internet Explorer, code for Outlook forms, or scripts for Windows Script Host, VBScript Pocket Reference will be your constant companion. Don't let the pocket-friendly format fool you. Based on the bestsellingVBScript in a Nutshell, this small book details every V

  18. 77 FR 76045 - Agency Forms Undergoing Paperwork Reduction Act Review

    Science.gov (United States)

    2012-12-26

    ... case classification (disease staging system). Recommendations for revisions in the case definition were... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention [30Day-13-0573] Agency Forms Undergoing Paperwork Reduction Act Review The Centers for Disease Control and Prevention...

  19. 75 FR 20601 - Agency Forms Undergoing Paperwork Reduction Act Review

    Science.gov (United States)

    2010-04-20

    .... Proposed Project Asthma Information Reporting System (AIRS)--New--Air Pollution and Respiratory Health... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention [30Day-10-09CK] Agency Forms Undergoing Paperwork Reduction Act Review The Centers for Disease Control and prevention...

  20. 78 FR 24422 - Agency Forms Undergoing Paperwork Reduction Act Review

    Science.gov (United States)

    2013-04-25

    ... System (AIRS) (0920-0853, Expiration 06/30/2013)--Extension--Air Pollution and Respiratory Health Branch... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention [30Day-13-0853] Agency Forms Undergoing Paperwork Reduction Act Review The Centers for Disease Control and Prevention...

  1. 1-GWh diurnal load-leveling Superconducting Magnetic Energy Storage System reference design. Appendix G. Design study. Thyristor converter stations for use with superconducting magnetic energy storage systems

    International Nuclear Information System (INIS)

    Lindh, C.B.; Pohl, R.V.; Trojan, H.T.

    1979-09-01

    The cost for the power conversion equipment for four different SMES systems were developed. These were 1- and 5-GWh units for 4- and 8-h charge periods. Only constant power operation of the converter was considered with 10% of the maximum energy remaining in the magnet at the end of the discharge cycle. The cost increases almost linearly with the maximum coil current between 30 kA and 150 kA, and the cost for a 4-h charge system is about 20% lower than for an 8-h charge system. The converter terminal cost is estimated to be $40/kW of installed power for a 1-GWh 4-h charge system at 30 kA maximum current and $60/kW of installed power for a 5-GWh 4-h charge system at 50 kA maximum current

  2. Coastwide Reference Monitoring System (CRMS) Vegetation Volume Index: An assessment tool for marsh habitat focused on the three-dimensional structure at CRMS vegetation monitoring stations

    Science.gov (United States)

    Wood, William B.; Visser, Jenneke M.; Piazza, Sarai C.; Sharp, Leigh A.; Hundy, Laura C.; McGinnis, Tommy E.

    2015-12-04

    A Vegetation Volume (VV) variable and Vegetation Volume Index (VVI) have been developed for the Coastwide Reference Monitoring System (CRMS). The VV is a measure of the amount of three-dimensional vegetative structure present at each CRMS site and is based on vegetation data collected annually. The VV uses 10 stations per CRMS site to quantify four vegetation layers: carpet, herbaceous, shrub, and tree. For each layer an overall live vegetation percent cover and height are collected to create a layer volume; the individual layer volumes are then summed to generate a site vegetation volume profile. The VV uses the two-dimensional area of live vegetative cover (in square meters) multiplied by the height (in meters) of each layer to produce a volume (in cubic meters) for each layer present in a 2-meter by 2-meter station. These layers are additive, yielding a total volume for each of the 10 herbaceous vegetation stations and an overall CRMS marsh site average.

  3. Towards absolute quantification of allergenic proteins in food--lysozyme in wine as a model system for metrologically traceable mass spectrometric methods and certified reference materials.

    Science.gov (United States)

    Cryar, Adam; Pritchard, Caroline; Burkitt, William; Walker, Michael; O'Connor, Gavin; Burns, Duncan Thorburn; Quaglia, Milena

    2013-01-01

    Current routine food allergen quantification methods, which are based on immunochemistry, offer high sensitivity but can suffer from issues of specificity and significant variability of results. MS approaches have been developed, but currently lack metrological traceability. A feasibility study on the application of metrologically traceable MS-based reference procedures was undertaken. A proof of concept involving proteolytic digestion and isotope dilution MS for quantification of protein allergens in a food matrix was undertaken using lysozyme in wine as a model system. A concentration of lysozyme in wine of 0.95 +/- 0.03 microg/g was calculated based on the concentrations of two peptides, confirming that this type of analysis is viable at allergenically meaningful concentrations. The challenges associated with this promising method were explored; these included peptide stability, chemical modification, enzymatic digestion, and sample cleanup. The method is suitable for the production of allergen in food certified reference materials, which together with the achieved understanding of the effects of sample preparation and of the matrix on the final results, will assist in addressing the bias of the techniques routinely used and improve measurement confidence. Confirmation of the feasibility of MS methods for absolute quantification of an allergenic protein in a food matrix with results traceable to the International System of Units is a step towards meaningful comparison of results for allergen proteins among laboratories. This approach will also underpin risk assessment and risk management of allergens in the food industry, and regulatory compliance of the use of thresholds or action levels when adopted.

  4. Patterns of intrafractional motion and uncertainties of treatment setup reference systems in accelerated partial breast irradiation for right- and left-sided breast cancer.

    Science.gov (United States)

    Yue, Ning J; Goyal, Sharad; Kim, Leonard H; Khan, Atif; Haffty, Bruce G

    2014-01-01

    This study investigated the patterns of intrafractional motion and accuracy of treatment setup strategies in 3-dimensional conformal radiation therapy of accelerated partial breast irradiation (APBI) for right- and left-sided breast cancers. Sixteen right-sided and 17 left-sided breast cancer patients were enrolled in an institutional APBI trial in which gold fiducial markers were strategically sutured to the surgical cavity walls. Daily pre- and postradiation therapy kV imaging were performed and were matched to digitally reconstructed radiographs based on bony anatomy and fiducial markers, respectively, to determine the intrafractional motion. The positioning differences of the laser-tattoo and the bony anatomy-based setups with respect to the marker-based setup (benchmark) were determined to evaluate their accuracy. Statistical differences were found between the right- and left-sided APBI treatments in vector directions of intrafractional motion and treatment setup errors in the reference systems, but less in their overall magnitudes. The directional difference was more pronounced in the lateral direction. It was found that the intrafractional motion and setup reference systems tended to deviate in the right direction for the right-sided breast treatments and in the left direction for the left-sided breast treatments. It appears that the fiducial markers placed in the seroma cavity exhibit side dependent directional intrafractional motion, although additional data may be needed to further validate the conclusion. The bony anatomy-based treatment setup improves the accuracy over laser-tattoo. But it is inadequate to rely on bony anatomy to assess intrafractional target motion in both magnitude and direction. Copyright © 2014 American Society for Radiation Oncology. Published by Elsevier Inc. All rights reserved.

  5. Preoperative information needs of children undergoing tonsillectomy.

    LENUS (Irish Health Repository)

    Buckley, Aoife

    2012-02-01

    AIMS AND OBJECTIVES: To identify the information needs of children undergoing tonsillectomy with reference to content of information, method of delivery, information providers and timing of information provision. BACKGROUND: Tonsillectomy can be anxiety provoking for children and preoperative preparation programmes are long recognised to reduce anxiety. However, few have been designed from the perspectives of children and to date little is known about how best to prepare children in terms of what to tell them, how to convey information to them, who can best provide information and what is the best timing for information provision. DESIGN: A qualitative descriptive study. METHOD: Data were collected from nine children (aged 6-9) using interviews supported by a write and draw technique. Data were coded and categorised into themes reflecting content, method, providers and timing of information. RESULTS: Children openly communicated their information needs especially on what to tell them to expect when facing a tonsillectomy. Their principal concerns were about operation procedures, experiencing \\'soreness\\' and discomfort postoperatively and parental presence. Mothers were viewed as best situated to provide them with information. Children were uncertain about what method of information and timing would be most helpful to them. CONCLUSION: Preoperative educational interventions need to take account of children\\'s information needs so that they are prepared for surgery in ways that are meaningful and relevant to them. Future research is needed in this area. RELEVANCE TO CLINICAL PRACTICE: Practical steps towards informing children about having a tonsillectomy include asking them what they need to know and addressing their queries accordingly. Child-centred information leaflets using a question and answer format could also be helpful to children.

  6. Automated transport and sorting system in a large reference laboratory: part 1. Evaluation of needs and alternatives and development of a plan.

    Science.gov (United States)

    Hawker, Charles D; Garr, Susan B; Hamilton, Leslie T; Penrose, John R; Ashwood, Edward R; Weiss, Ronald L

    2002-10-01

    Our laboratory, a large, commercial, esoteric reference laboratory, sought some form of total laboratory automation to keep pace with rapid growth of specimen volumes as well as to meet competitive demands for cost reduction and improved turnaround time. We conducted a systematic evaluation of our needs, which led to the development of a plan to implement an automated transport and sorting system. We systematically analyzed and studied our specimen containers, test submission requirements and temperatures, and the workflow and movement of people, specimens, and information throughout the laboratory. We performed an intricate timing study that identified bottlenecks in our manual handling processes. We also evaluated various automation options. The automation alternative viewed to best meet our needs was a transport and sorting system from MDS AutoLab. Our comprehensive plan also included a new standardized transport tube; a centralized automated core laboratory for higher volume tests; a new "automation-friendly" software system for order entry, tracking, and process control; a complete reengineering of our order-entry, handling, and tracking processes; and remodeling of our laboratory facility and specimen processing area. The scope of this project and its potential impact on overall laboratory operations and performance justified the extensive time we invested (nearly 4 years) in a systematic approach to the evaluation, design, and planning of this project.

  7. Value-Based Assessment of Radiology Reporting Using Radiologist-Referring Physician Two-Way Feedback System-a Design Thinking-Based Approach.

    Science.gov (United States)

    Shaikh, Faiq; Hendrata, Kenneth; Kolowitz, Brian; Awan, Omer; Shrestha, Rasu; Deible, Christopher

    2017-06-01

    In the era of value-based healthcare, many aspects of medical care are being measured and assessed to improve quality and reduce costs. Radiology adds enormously to health care costs and is under pressure to adopt a more efficient system that incorporates essential metrics to assess its value and impact on outcomes. Most current systems tie radiologists' incentives and evaluations to RVU-based productivity metrics and peer-review-based quality metrics. In a new potential model, a radiologist's performance will have to increasingly depend on a number of parameters that define "value," beginning with peer review metrics that include referrer satisfaction and feedback from radiologists to the referring physician that evaluates the potency and validity of clinical information provided for a given study. These new dimensions of value measurement will directly impact the cascade of further medical management. We share our continued experience with this project that had two components: RESP (Referrer Evaluation System Pilot) and FRACI (Feedback from Radiologist Addressing Confounding Issues), which were introduced to the clinical radiology workflow in order to capture referrer-based and radiologist-based feedback on radiology reporting. We also share our insight into the principles of design thinking as applied in its planning and execution.

  8. The self-referred mammography patient

    International Nuclear Information System (INIS)

    Reynolds, H.E.; Jackson, V.P.

    1990-01-01

    This paper compares the demographics, knowledge, and attitudes of women who refer themselves for screening mammography with those who undergo mammography on the advice of their physicians. Four hundred eighty-five consecutive mammography patients (437 doctor preferred [DR], 48 self-referred [SR]) completed a survey during their mammography appointment. The sample population contained a wide range of socioeconomic groups. While similar in age, race, and employment status to DR patients, SR patients were significantly more likely to have a family income of more than 30,000 per year, be college graduates, and report that they were in good or excellent health

  9. New design and facilities for the International Database for Absolute Gravity Measurements (AGrav): A support for the Establishment of a new Global Absolute Gravity Reference System

    Science.gov (United States)

    Wziontek, Hartmut; Falk, Reinhard; Bonvalot, Sylvain; Rülke, Axel

    2017-04-01

    After about 10 years of successful joint operation by BGI and BKG, the International Database for Absolute Gravity Measurements "AGrav" (see references hereafter) was under a major revision. The outdated web interface was replaced by a responsive, high level web application framework based on Python and built on top of Pyramid. Functionality was added, like interactive time series plots or a report generator and the interactive map-based station overview was updated completely, comprising now clustering and the classification of stations. Furthermore, the database backend was migrated to PostgreSQL for better support of the application framework and long-term availability. As comparisons of absolute gravimeters (AG) become essential to realize a precise and uniform gravity standard, the database was extended to document the results on international and regional level, including those performed at monitoring stations equipped with SGs. By this it will be possible to link different AGs and to trace their equivalence back to the key comparisons under the auspices of International Committee for Weights and Measures (CIPM) as the best metrological realization of the absolute gravity standard. In this way the new AGrav database accommodates the demands of the new Global Absolute Gravity Reference System as recommended by the IAG Resolution No. 2 adopted in Prague 2015. The new database will be presented with focus on the new user interface and new functionality, calling all institutions involved in absolute gravimetry to participate and contribute with their information to built up a most complete picture of high precision absolute gravimetry and improve its visibility. A Digital Object Identifier (DOI) will be provided by BGI to contributors to give a better traceability and facilitate the referencing of their gravity surveys. Links and references: BGI mirror site : http://bgi.obs-mip.fr/data-products/Gravity-Databases/Absolute-Gravity-data/ BKG mirror site: http

  10. rf reference line for PEP

    International Nuclear Information System (INIS)

    Schwarz, H.D.; Weaver, J.N.

    1979-03-01

    A rf phase reference line in 6 segments around the 2200 meter circumference PEP storage ring is described. Each segment of the reference line is phase stabilized by its own independent feedback system, which uses an amplitude modulated reflection from the end of each line. The modulation is kept small and decoupled from the next segment to avoid crosstalk and significant modulation of the rf drive signal. An error evaluation of the system is made. The technical implementation and prototype performance are described. Prototype tests indicate that the phase error around the ring can be held below 1 degree with this relatively simple system

  11. rf reference line for PEP

    Energy Technology Data Exchange (ETDEWEB)

    Schwarz, H.D.; Weaver, J.N.

    1979-03-01

    A rf phase reference line in 6 segments around the 2200 meter circumference PEP storage ring is described. Each segment of the reference line is phase stabilized by its own independent feedback system, which uses an amplitude modulated reflection from the end of each line. The modulation is kept small and decoupled from the next segment to avoid crosstalk and significant modulation of the rf drive signal. An error evaluation of the system is made. The technical implementation and prototype performance are described. Prototype tests indicate that the phase error around the ring can be held below 1 degree with this relatively simple system.

  12. Certified Reference Material for Use in 1H, 31P, and 19F Quantitative NMR, Ensuring Traceability to the International System of Units.

    Science.gov (United States)

    Rigger, Romana; Rück, Alexander; Hellriegel, Christine; Sauermoser, Robert; Morf, Fabienne; Breitruck, KathrinBreitruck; Obkircher, Markus

    2017-09-01

    In recent years, quantitative NMR (qNMR) spectroscopy has become one of the most important tools for content determination of organic substances and quantitative evaluation of impurities. Using Certified Reference Materials (CRMs) as internal or external standards, the extensively used qNMR method can be applied for purity determination, including unbroken traceability to the International System of Units (SI). The implementation of qNMR toward new application fields, e.g., metabolomics, environmental analysis, and physiological pathway studies, brings along more complex molecules and systems, thus making use of 1H qNMR challenging. A smart workaround is possible by the use of other NMR active nuclei, namely 31P and 19F. This article presents the development of three classes of qNMR CRMs based on different NMR active nuclei (1H, 31P, and 19F), and the corresponding approaches to establish traceability to the SI through primary CRMs from the National Institute of Standards and Technology and the National Metrology Institute of Japan. These TraceCERT® qNMR CRMs are produced under ISO/IEC 17025 and ISO Guide 34 using high-performance qNMR.

  13. 2002 reference document; Document de reference 2002

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2002-07-01

    This 2002 reference document of the group Areva, provides information on the society. Organized in seven chapters, it presents the persons responsible for the reference document and for auditing the financial statements, information pertaining to the transaction, general information on the company and share capital, information on company operation, changes and future prospects, assets, financial position, financial performance, information on company management and executive board and supervisory board, recent developments and future prospects. (A.L.B.)

  14. Automated transport and sorting system in a large reference laboratory: part 2. Implementation of the system and performance measures over three years.

    Science.gov (United States)

    Hawker, Charles D; Roberts, William L; Garr, Susan B; Hamilton, Leslie T; Penrose, John R; Ashwood, Edward R; Weiss, Ronald L

    2002-10-01

    Our laboratory implemented a major automation system in November 1998. A related report describes a 4-year process of evaluation and planning leading to system installation. This report describes the implementation and performance results over 3 years since the system was placed into use. Project management software was used to track the project. Turnaround times of our top 500 tests before and after automation were measured. We compared the rate of hiring of employees and the billed unit per employee ratio before and after automation by use of linear regression analysis. Finally, we analyzed the financial contribution of the project through an analysis of return on investment. Since implementation, the volume of work transported and sorted has grown to >15,000 new tubes and >25,000 total tubes per day. Median turnaround time has decreased by an estimated 7 h, and turnaround time at the 95th percentile has decreased by 12 h. Lost specimens have decreased by 58%. A comparison of pre- and post-implementation hiring rates of employees estimated a savings of 33.6 employees, whereas a similar comparison of ratios of billed units per employee estimated a savings of 49.1 employees. Using the higher figure, we estimated that the $4.02 million cost of the project would be paid off approximately 4.9 years subsequent to placing the system into daily use. The overall automation project implemented in our laboratory has contributed considerably to improvement of key performance measures and has met our original project objectives.

  15. VBE reference framework

    NARCIS (Netherlands)

    Afsarmanesh, H.; Camarinha-Matos, L.M.; Ermilova, E.; Camarinha-Matos, L.M.; Afsarmanesh, H.; Ollus, M.

    2008-01-01

    Defining a comprehensive and generic "reference framework" for Virtual organizations Breeding Environments (VBEs), addressing all their features and characteristics, is challenging. While the definition and modeling of VBEs has become more formalized during the last five years, "reference models"

  16. CMS Statistics Reference Booklet

    Data.gov (United States)

    U.S. Department of Health & Human Services — The annual CMS Statistics reference booklet provides a quick reference for summary information about health expenditures and the Medicare and Medicaid health...

  17. [Definition and specification requirements for PAC-systems (picture archiving and communication system). A performance index with reference to the standard "IEEE Recommended Practice for Software Requirement Specifications"].

    Science.gov (United States)

    König, H; Klose, K J

    1999-04-01

    The formulation of requirements is necessary to control the goals of a PACS project. Furthermore, in this way, the scope of functionality necessary to support radiological working processes becomes clear. Definitions of requirements and specification are formulated independently of systems according to the IEEE standard "Recommended Practice for Software Requirements Specifications". Definitions are given in the Request for Information, specifications in the Request for Proposal. Functional and non-functional requirements are distinguished. The solutions are rated with respect to scope, appropriateness and quality of implementation. A PACS checklist was created according to the methods described above. It is published on the homepage of the "Arbeitsgemeinschaft Informationstechnologie" (AGIT) within the "Deutsche Röntgengesellschaft" (DRG) (http://www.uni-marburg.de/mzr/agit). The checklist provides a discussion forum which should contribute to an agreement on accepted basic PACS functionalities.

  18. Plasma fibronectin in patients undergoing major surgery

    International Nuclear Information System (INIS)

    Sallam, M.H.M.

    2003-01-01

    Plasma fibronectin in patients undergoing major surgery had been determined before and after operation. The study was done on 15 patients and 15 normal healthy individuals. The study revealed that patients subjected to major operation, their fibronectin level was normal before operation followed by reduction one day post-operation. After one week, fibronectin level raised again nearly to the pre-operations levels. The probable mechanisms of fibronectin in healing processes were discussed. Fibronectin (FN) is a family of structurally and immunologically related high molecular weight glycoproteins that are present in many cell surfaces, in extracellular fluids, in connective tissues and in most membranes. Interaction with certain discrete extracellular substances, such as a glucosaminoglycans (e.g. heparin), fibrin and collagen and with cell surface structure seem to account for many of its biological activities, among which are regulation of adhesion, spreading and locomotion (Mosesson and amrani, 1980). The concentration of Fn in human plasma decreases after extensive destruction such as that occurs in major surgery, burns or other trauma. This decrease has been generally though to be due to increased consumption of soluble plasma Fn in opsonization of particulate and soluble debris from circulation by the reticuloendothelial (RE) system. Fn rapidly appears in injury areas, in experimentally induced blisters, wounded and epithelium tissues (Petersen et al., 1985). Fn accumulates at times of increased vascular permeability and it is produced by cell of blood vessels in response to injury

  19. Specialised care in patients undergoing pancreatoduodenectomy

    NARCIS (Netherlands)

    Tol, J.A.M.G.

    2014-01-01

    This thesis studies the controversies in the management of patients with pancreatic cancer undergoing pancreatoduodenectomy and determines different factors that will improve this management and thereby the postoperative outcomes. The studies were performed in both the pre-, peri- and postoperative

  20. Antibiotic prophylaxis for patients undergoing elective endoscopic ...

    African Journals Online (AJOL)

    Antibiotic prophylaxis for patients undergoing elective endoscopic retrograde cholangiopancreatography. M Brand, D Bisoz. Abstract. Background. Antibiotic prophylaxis for endoscopic retrograde cholangiopancreatography (ERCP) is controversial. We set out to assess the current antibiotic prescribing practice among ...

  1. Actuation crosstalk in free-falling systems: Torsion pendulum results for the engineering model of the LISA pathfinder gravitational reference sensor

    Science.gov (United States)

    Bassan, M.; Cavalleri, A.; De Laurentis, M.; De Marchi, F.; De Rosa, R.; Di Fiore, L.; Dolesi, R.; Finetti, N.; Garufi, F.; Grado, A.; Hueller, M.; Marconi, L.; Milano, L.; Minenkov, Y.; Pucacco, G.; Stanga, R.; Vetrugno, D.; Visco, M.; Vitale, S.; Weber, W. J.

    2018-01-01

    In this paper we report on measurements on actuation crosstalk, relevant to the gravitational reference sensors for LISA Pathfinder and LISA. In these sensors, a Test Mass (TM) falls freely within a system of electrodes used for readout and control. These measurements were carried out on ground with a double torsion pendulum that allowed us to estimate both the torque injected into the sensor when a control force is applied and, conversely, the force leaking into the translational degree of freedom due to the applied torque.The values measured on our apparatus (the engineering model of the LISA Pathfinder sensor) agree to within 0.2% (over a maximum measured crosstalk of 1%) with predictions of a mathematical model when measuring force to torque crosstalk, while it is somewhat larger than expected (up to 3.5%) when measuring torque to force crosstalk. However, the values in the relevant range, i.e. when the TM is well centered ( ± 10 μm) in the sensor, remain smaller than 0.2%, satisfying the LISA Pathfinder requirements.

  2. Evaluation of the signal-to-noise ratio (SNR) in a CR system and establishment of RQR-M and RQA-M IEC reference radiations in mammography

    International Nuclear Information System (INIS)

    Rosado, Paulo H.G.; Nogueira, Maria S.; Dantas, Marcelino V.A.; Santana, Priscila do C.

    2009-01-01

    In this work, the radiation condition RQR-M e RQA-M of IEC were established in the Siemens Mammomat 3000 mammography equipment. The standard radiation condition are described in terms of: emitting target of molybdenum, percentage ripple not more that 4%, total filtration of 0,032 ± 0,002 mm of molybdenum and specific values of first half-value layer. The results show that the values of parameters were in the range that the IEC recommends. Only the RQAM-3 the value of CSR was not in agreement of the value recommend, and was necessary a additions of 0,1 mm Al in the x-ray tube. After this, the signal noise ratio (SNR) of de Computer radiography (CR) system was evaluated in the reference qualities of RQR-M e RQA-M. For SNR the RQR-M mode of exposure was done with both the 20 mAs and automatic one. To RQA-M the exposure was done with 100 mAs. The variations of the values of SNR were approximated 4%. The tests were done with CR model CR850 made from Kodak and 40 mm of PMMA. (author)

  3. IAEA biological reference materials

    International Nuclear Information System (INIS)

    Parr, R.M.; Schelenz, R.; Ballestra, S.

    1988-01-01

    The Analytical Quality Control Services programme of the IAEA encompasses a wide variety of intercomparisons and reference materials. This paper reviews only those aspects of the subject having to do with biological reference materials. The 1988 programme foresees 13 new intercomparison exercises, one for major, minor and trace elements, five for radionuclides, and seven for stable isotopes. Twenty-two natural matrix biological reference materials are available: twelve for major, minor and trace elements, six for radionuclides, and four for chlorinated hydrocarbons. Seven new intercomparisons and reference materials are in preparation or under active consideration. Guidelines on the correct use of reference materials are being prepared for publication in 1989 in consultation with other major international producers and users of biological reference materials. The IAEA database on available reference materials is being updated and expanded in scope, and a new publication is planned for 1989. (orig.)

  4. An analog cell to detect single event transients in voltage references

    Energy Technology Data Exchange (ETDEWEB)

    Franco, F.J., E-mail: fjfranco@fis.ucm.es [Departamento de Física Aplicada III, Facultad de Físicas, Universidad Complutense de Madrid (UCM), 28040 Madrid (Spain); Palomar, C. [Departamento de Física Aplicada III, Facultad de Físicas, Universidad Complutense de Madrid (UCM), 28040 Madrid (Spain); Izquierdo, J.G. [Centro de Láseres Ultrarrápidos, Facultad de Químicas, Universidad Complutense de Madrid (UCM), 28040 Madrid (Spain); Agapito, J.A. [Departamento de Física Aplicada III, Facultad de Físicas, Universidad Complutense de Madrid (UCM), 28040 Madrid (Spain)

    2015-01-11

    A reliable voltage reference is mandatory in mixed-signal systems. However, this family of components can undergo very long single event transients when operating in radiation environments such as space and nuclear facilities due to the impact of heavy ions. The purpose of the present paper is to demonstrate how a simple cell can be used to detect these transients. The cell was implemented with typical COTS components and its behavior was verified by SPICE simulations and in a laser facility. Different applications of the cell are explored as well.

  5. Sensor Characteristics Reference Guide

    Energy Technology Data Exchange (ETDEWEB)

    Cree, Johnathan V.; Dansu, A.; Fuhr, P.; Lanzisera, Steven M.; McIntyre, T.; Muehleisen, Ralph T.; Starke, M.; Banerjee, Pranab; Kuruganti, T.; Castello, C.

    2013-04-01

    The Buildings Technologies Office (BTO), within the U.S. Department of Energy (DOE), Office of Energy Efficiency and Renewable Energy (EERE), is initiating a new program in Sensor and Controls. The vision of this program is: • Buildings operating automatically and continuously at peak energy efficiency over their lifetimes and interoperating effectively with the electric power grid. • Buildings that are self-configuring, self-commissioning, self-learning, self-diagnosing, self-healing, and self-transacting to enable continuous peak performance. • Lower overall building operating costs and higher asset valuation. The overarching goal is to capture 30% energy savings by enhanced management of energy consuming assets and systems through development of cost-effective sensors and controls. One step in achieving this vision is the publication of this Sensor Characteristics Reference Guide. The purpose of the guide is to inform building owners and operators of the current status, capabilities, and limitations of sensor technologies. It is hoped that this guide will aid in the design and procurement process and result in successful implementation of building sensor and control systems. DOE will also use this guide to identify research priorities, develop future specifications for potential market adoption, and provide market clarity through unbiased information

  6. Evaluation of Diabetes Quality of Care Based on a Care Scoring System among People Referring to Diabetes Clinic in Ardabil, 2014

    Directory of Open Access Journals (Sweden)

    J Ataei

    2015-06-01

    Full Text Available Background & objectives: Successful implementation of diabetes care can reduce acute and chronic complications of diabetes. This study was conducted to evaluate the quality of care according to a care scoring system among people with type 2 diabetes referring to the diabetes clinic in Ardabil. Methods: This cross sectional study was conducted in 2014 and a total of 300 people with type 2 diabetes in age range of 20-70 years old were included via convenience sampling. Data were collected by an interviewer using a structured questionnaire and checklist. Each patient was classified according to a quality of care scoring system into 3 categories: ≤10, 15-20, >20. Statistical analysis performed by SPSS v.20 software and descriptive analysis used to display data as frequency tables and graphs. Analytical tests such as ANOVA, Kruskal-Wallis, Chi squared, and fisher exact test were also used to analyze the data. Results: The mean age of patients was 54.13 ± 9.13 and the majority of them were women (72.3%. The mean of BMI and HbA1c was 29.58 ± 4.77 and 8.93± 2.13, respectively. The mean of FBS was 191.18 ± 84.23 and the average length of disease was 7.74±5.89 years. The mean of quality of care score among participants was 23.20±9.99. About one-third of patients (29.7% had a quality care score ≤10, half of them (51% had a score between 15-20, and only 19.35% had a score >20. There was an association between HbA1c, FBS, diastolic blood pressure, cholesterol and LDL with a quality of care score which was statistically significant (p<0.05. Conclusion: In this study there was a gap between the current quality of care of patients and recommended standards. Therefore in order to minimize the current barriers and problems it is recommended to implement an effective interventional program. In addition, using a quality care scoring system is a rapid, easy and valid method for evaluating diabetes quality of care.

  7. Internal validation of the DNAscan/ANDE™ Rapid DNA Analysis™ platform and its associated PowerPlex® 16 high content DNA biochip cassette for use as an expert system with reference buccal swabs.

    Science.gov (United States)

    Moreno, Lilliana I; Brown, Alice L; Callaghan, Thomas F

    2017-07-01

    Rapid DNA platforms are fully integrated systems capable of producing and analyzing short tandem repeat (STR) profiles from reference sample buccal swabs in less than two hours. The technology requires minimal user interaction and experience making it possible for high quality profiles to be generated outside an accredited laboratory. The automated production of point of collection reference STR profiles could eliminate the time delay for shipment and analysis of arrestee samples at centralized laboratories. Furthermore, point of collection analysis would allow searching against profiles from unsolved crimes during the normal booking process once the infrastructure to immediately search the Combined DNA Index System (CODIS) database from the booking station is established. The DNAscan/ANDE™ Rapid DNA Analysis™ System developed by Network Biosystems was evaluated for robustness and reliability in the production of high quality reference STR profiles for database enrollment and searching applications. A total of 193 reference samples were assessed for concordance of the CODIS 13 loci. Studies to evaluate contamination, reproducibility, precision, stutter, peak height ratio, noise and sensitivity were also performed. The system proved to be robust, consistent and dependable. Results indicated an overall success rate of 75% for the 13 CODIS core loci and more importantly no incorrect calls were identified. The DNAscan/ANDE™ could be confidently used without human interaction in both laboratory and non-laboratory settings to generate reference profiles. Published by Elsevier B.V.

  8. Radiological diagnosis of renal osteodystrophy with reference to clinical features in patients undergoing maintenance hemodialysis

    International Nuclear Information System (INIS)

    Huebsch, P.; Trattnig, S.; Barton, P.; Seidl, G.

    1989-01-01

    Pathophysiological, histological and radiological findings in renal osteodystrophy are described. Special emphasis is laid on secondary hyperparathyroidism. Preliminary results of the authors' investigations show a good correlation between radiological findings in the phalanges of the hand and the concentration of parathyroid hormone (PTH) in 14 patients. The concentration of the hormone in the blood was measured by a new 'two-site' immunoradiometric assay, which is specific for the intact, biologically active hormone. Patients with high concentrations of PTH in the blood tended to have more severe radiological changes. In 4 patients for whom radiographs of the hands revealed no pathologic findings, normal PTH concentrations in the blood were measured by this method, whereas the conventional assay gave elevated hormone concentrations for the same patients. This is due to the lack of specificity of the conventional method for the intact, biologically active hormone. Nevertheless, further investigations are needed to confirm these findings. (orig.) [de

  9. Indoor air: Reference bibliography

    International Nuclear Information System (INIS)

    Campbell, D.; Staves, D.; McDonald, S.

    1989-07-01

    The U. S. Environmental Protection Agency initially established the indoor air Reference Bibliography in 1987 as an appendix to the Indoor Air Quality Implementation Plan. The document was submitted to Congress as required under Title IV--Radon Gas and Indoor Air Quality Research of the Superfund Amendments and Reauthorization Act of 1986. The Reference Bibliography is an extensive bibliography of reference materials on indoor air pollution. The Bibliography contains over 4500 citations and continues to increase as new articles appear

  10. Nuclear Structure References (NSR) file

    International Nuclear Information System (INIS)

    Ewbank, W.B.

    1978-08-01

    The use of the Nuclear Structure References file by the Nuclear Data Project at ORNL is described. Much of the report concerns format information of interest only to those preparing input to the system or otherwise needing detailed knowledge of its internal structure. 17 figures

  11. Android quick APIs reference

    CERN Document Server

    Cinar, Onur

    2015-01-01

    The Android Quick APIs Reference is a condensed code and APIs reference for the new Google Android 5.0 SDK. It presents the essential Android APIs in a well-organized format that can be used as a handy reference. You won't find any technical jargon, bloated samples, drawn out history lessons, or witty stories in this book. What you will find is a software development kit and APIs reference that is concise, to the point and highly accessible. The book is packed with useful information and is a must-have for any mobile or Android app developer or programmer. In the Android Quick APIs Refe

  12. Body mass and body weight: a dual reference system in biology Masa y peso corporales: un sistema dual de referencia en biología

    Directory of Open Access Journals (Sweden)

    BRUNO GÜNTHER

    2003-03-01

    Full Text Available ABSTRACT The aim of the present study was to compare two different biological similarity criteria, one was based on body mass (M as a theoretical reference system in accordance with the MLT-system of physics, while the other utilized the body weight (W for the same purpose. The mass-dependent allometry should be applied during space flights as well as during fetal and newborn conditions of life, whereas the weight-dependence should prevail in earth-bound physiology. The above mentioned distinctions are relevant not only for the specific metabolic rates but also for numerous biological time functions, as for instance for the heart and respiratory rates of all mammals, whose allometric exponent is b = - 0.09 during fetal life, and b = - 0.25 in all adult specimens.El objetivo del presente trabajo fue la comparación de dos diferentes criterios de similitud, uno basado en la masa corporal (M como sistema teórico de referencia de acuerdo con el sistema MLT de la Física, en tanto que el otro utilizó el peso corporal (W con este mismo propósito. La alometría dependiente de la masa debería aplicarse durante los vuelos espaciales así como durante la vida fetal y la condición de recién nacido, en tanto que la dependencia del peso debe prevalecer en la fisiología terrestre. La distinción antes mencionada es relevante, no sólo para el metabolismo específico y también para numerosas funciones biológicas en relación con funciones de tiempo, como ser con las frecuencias cardiaca y respiratoria de todos los mamíferos cuyo exponente alométrico es b = - 0,09 durante la vida fetal, y b = - 0,25 en todos los especimenes adultos.

  13. Sizewell 'B' PWR reference design

    International Nuclear Information System (INIS)

    1982-04-01

    The reference design for a PWR power station to be constructed as Sizewell 'B' is presented in 3 volumes containing 14 chapters and in a volume of drawings. The report describes the proposed design and provides the basis upon which the safety case and the Pre-Construction Safety Report have been prepared. The station is based on a 3425MWt Westinghouse PWR providing steam to two turbine generators each of 600 MW. The layout and many of the systems are based on the SNUPPS design for Callaway which has been chosen as the US reference plant for the project. (U.K.)

  14. Marketing Reference Services.

    Science.gov (United States)

    Norman, O. Gene

    1995-01-01

    Relates the marketing concept to library reference services. Highlights include a review of the literature and an overview of marketing, including research, the marketing mix, strategic plan, marketing plan, and marketing audit. Marketing principles are applied to reference services through the marketing mix elements of product, price, place, and…

  15. Reference class forecasting

    DEFF Research Database (Denmark)

    Flyvbjerg, Bent

    optimisme og misinformation. RCF bygger på teorier, som vandt Daniel Kahneman Nobelprisen i økonomi i 2002. RCF estimerer budgettet for et givet projekt på grundlag af de faktiske udfald for budgetterne i en reference-klasse af projekter. RCF udføres i tre trin: 1. Identifikation af en relevant reference...

  16. DRIRU I/SKIRU - The application of the DTG to spacecraft attitude control. [Dynamically-Tuned Gyro for Inertial Reference Unit systems

    Science.gov (United States)

    Swanson, C. O.

    1982-01-01

    The dynamically tuned gyro (DTG) was developed to replace the floated, rate integrating gyro used for space attitude control, as the DTG fulfills cost, performance, and reliability requirements not satisfied by its predecessor. The use of this gyro in the Dry Gyro Inertial Reference Unit I (DRIRU I) marked the first application of a DTG in a spacecraft attitude reference unit. Design and performance characteristics of DTG application in the Singer-Kearfott Inertial Reference Unit (SKIRU) are outlined, for example its minimal weight (7 lb), and operational reliability. The DTG has accomplished 156,000 failure-free hours, and a chart, logging test performance, indicates that this and other requirements were more than sufficiently satisfied. The unit has an unparalleled life span, with several units still operating after 70,000 to 130,000 hours, and a random drift which always remains under 0.0005 deg/h. Potential for improvements, such as drift performance, are considered.

  17. Uranium reference materials

    International Nuclear Information System (INIS)

    Donivan, S.; Chessmore, R.

    1987-07-01

    The Technical Measurements Center has prepared uranium mill tailings reference materials for use by remedial action contractors and cognizant federal and state agencies. Four materials were prepared with varying concentrations of radionuclides, using three tailings materials and a river-bottom soil diluent. All materials were ground, dried, and blended thoroughly to ensure homogeneity. The analyses on which the recommended values for nuclides in the reference materials are based were performed, using independent methods, by the UNC Geotech (UNC) Chemistry Laboratory, Grand Junction, Colorado, and by C.W. Sill (Sill), Idaho National Engineering Laboratory, Idaho Falls, Idaho. Several statistical tests were performed on the analytical data to characterize the reference materials. Results of these tests reveal that the four reference materials are homogeneous and that no large systematic bias exists between the analytical methods used by Sill and those used by TMC. The average values for radionuclides of the two data sets, representing an unbiased estimate, were used as the recommended values for concentrations of nuclides in the reference materials. The recommended concentrations of radionuclides in the four reference materials are provided. Use of these reference materials will aid in providing uniform standardization among measurements made by remedial action contractors. 11 refs., 9 tabs

  18. Adaptation of penelope Monte Carlo code system to the absorbed dose metrology: characterization of high energy photon beams and calculations of reference dosimeter correction factors; Adaptation du code Monte Carlo penelope pour la metrologie de la dose absorbee: caracterisation des faisceaux de photons X de haute energie et calcul de facteurs de correction de dosimetres de reference

    Energy Technology Data Exchange (ETDEWEB)

    Mazurier, J

    1999-05-28

    This thesis has been performed in the framework of national reference setting-up for absorbed dose in water and high energy photon beam provided with the SATURNE-43 medical accelerator of the BNM-LPRI (acronym for National Bureau of Metrology and Primary standard laboratory of ionising radiation). The aim of this work has been to develop and validate different user codes, based on PENELOPE Monte Carlo code system, to determine the photon beam characteristics and calculate the correction factors of reference dosimeters such as Fricke dosimeters and graphite calorimeter. In the first step, the developed user codes have permitted the influence study of different components constituting the irradiation head. Variance reduction techniques have been used to reduce the calculation time. The phase space has been calculated for 6, 12 and 25 MV at the output surface level of the accelerator head, then used for calculating energy spectra and dose distributions in the reference water phantom. Results obtained have been compared with experimental measurements. The second step has been devoted to develop an user code allowing calculation correction factors associated with both BNM-LPRI's graphite and Fricke dosimeters thanks to a correlated sampling method starting with energy spectra obtained in the first step. Then the calculated correction factors have been compared with experimental and calculated results obtained with the Monte Carlo EGS4 code system. The good agreement, between experimental and calculated results, leads to validate simulations performed with the PENELOPE code system. (author)

  19. A reference dosimetric system for dose interval of radiotherapy based on alanine/RPE; Um sistema dosimetrico de referencia para o intervalo de doses da radioterapia baseado na alanina/RPE

    Energy Technology Data Exchange (ETDEWEB)

    Rodrigues Junior, Orlando; Galante, Ocimar L.; Campos, Leticia L. [Instituto de Pesquisas Energeticas e Nucleares (IPEN), Sao Paulo, SP (Brazil)]. E-mail: rodrijr@net.ipen.br

    2001-07-01

    This work describes the development of a reference dosimetric system based on alanine/EPR for radiotherapy dose levels. Currently the IPEN is concluding a similar system for the dose range used for irradiation of products, 10-10{sup 5} Gy. The objective of this work is to present the efforts towards to improve the measure accuracy for doses in the range between 1-10 Gy. This system could be used as reference by radiotherapy services, as much in the quality control of the equipment, as for routine accompaniment of more complex handling where the total doses can reach some grays. The system uses alanine as detector and electronic paramagnetic resonance - EPR as measure technique. To reach accuracy better than 5% mathematical studies on the best optimization of the EPR spectrometer parameters and methods for the handling of the EPR sign are discussed. (author)

  20. STL pocket reference

    CERN Document Server

    Lischner, Ray

    2003-01-01

    The STL Pocket Reference describes the functions, classes, and templates in that part of the C++ standard library often referred to as the Standard Template Library (STL). The STL encompasses containers, iterators, algorithms, and function objects, which collectively represent one of the most important and widely used subsets of standard library functionality. The C++ standard library, even the subset known as the STL, is vast. It's next to impossible to work with the STL without some sort of reference at your side to remind you of template parameters, function invocations, return types--ind