WorldWideScience

Sample records for reference system nsrs

  1. Pathway to 2022: The Ongoing Modernization of the United States National Spatial Reference System

    Science.gov (United States)

    Stone, W. A.; Caccamise, D.

    2017-12-01

    The National Oceanic and Atmospheric Administration's National Geodetic Survey (NGS) mission is "to define, maintain and provide access to the National Spatial Reference System (NSRS) to meet our nation's economic, social, and environmental needs." The NSRS is an assemblage of geophysical and geodetic models, tools, and data, with the most-visible components being the North American Datum of 1983 (NAD83) and the North American Vertical Datum of 1988 (NAVD88), which together provide a consistent spatial reference framework for myriad geospatial applications and positioning requirements throughout the United States. The NGS is engaged in an ongoing and comprehensive multi-year project of modernizing the NSRS, a makeover necessitated by technological developments and user accuracy requirements, all with a goal of providing a modern, accurate, accessible, and globally aligned national positioning framework exploiting the substantial power and utility of the Global Navigation Satellite System - of both today and tomorrow. The modernized NSRS will include four new-generation geometric terrestrial reference frames (replacing NAD83) and a technically unprecedented geopotential datum (replacing NAVD88), all to be released in 2022 (anticipated). This poster/presentation will describe the justification for this modernization effort and will update the status and planned evolution of the NSRS as 2022 draws ever closer. Also discussed will be recent developments, including the publication of "blueprint" documents addressing technical details of various facets of the modernized NSRS and a continued series of public Geospatial Summits. Supporting/ancillary projects such as Gravity for the Redefinition of the American Vertical Datum (GRAV-D), which will result in the generation of a highly accurate gravimetric geoid - or definitional reference surface (zero elevation) - for the future geopotential datum, and Geoid Slope Validation Surveys (GSVS), which are exploring the achievable

  2. Latest performance of ArF immersion scanner NSR-S630D for high-volume manufacturing for 7nm node

    Science.gov (United States)

    Funatsu, Takayuki; Uehara, Yusaku; Hikida, Yujiro; Hayakawa, Akira; Ishiyama, Satoshi; Hirayama, Toru; Kono, Hirotaka; Shirata, Yosuke; Shibazaki, Yuichi

    2015-03-01

    In order to achieve stable operation in cutting-edge semiconductor manufacturing, Nikon has developed NSR-S630D with extremely accurate overlay while maintaining throughput in various conditions resembling a real production environment. In addition, NSR-S630D has been equipped with enhanced capabilities to maintain long-term overlay stability and user interface improvement all due to our newly developed application software platform. In this paper, we describe the most recent S630D performance in various conditions similar to real productions. In a production environment, superior overlay accuracy with high dose conditions and high throughput are often required; therefore, we have performed several experiments with high dose conditions to demonstrate NSR's thermal aberration capabilities in order to achieve world class overlay performance. Furthermore, we will introduce our new software that enables long term overlay performance.

  3. Space-Time Reference Systems

    CERN Document Server

    Soffel, Michael

    2013-01-01

    The high accuracy of modern astronomical spatial-temporal reference systems has made them considerably complex. This book offers a comprehensive overview of such systems. It begins with a discussion of ‘The Problem of Time’, including recent developments in the art of clock making (e.g., optical clocks) and various time scales. The authors address  the definitions and realization of spatial coordinates by reference to remote celestial objects such as quasars. After an extensive treatment of classical equinox-based coordinates, new paradigms for setting up a celestial reference system are introduced that no longer refer to the translational and rotational motion of the Earth. The role of relativity in the definition and realization of such systems is clarified. The topics presented in this book are complemented by exercises (with solutions). The authors offer a series of files, written in Maple, a standard computer algebra system, to help readers get a feel for the various models and orders of magnitude. ...

  4. Korean Reference HLW Disposal System

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Heui Joo; Lee, J. Y.; Kim, S. S. (and others)

    2008-03-15

    This report outlines the results related to the development of Korean Reference Disposal System for High-level radioactive wastes. The research has been supported around for 10 years through a long-term research plan by MOST. The reference disposal method was selected via the first stage of the research during which the technical guidelines for the geological disposal of HLW were determined too. At the second stage of the research, the conceptual design of the reference disposal system was made. For this purpose the characteristics of the reference spent fuels from PWR and CANDU reactors were specified, and the material and specifications of the canisters were determined in term of structural analysis and manufacturing capability in Korea. Also, the mechanical and chemical characteristics of the domestic Ca-bentonite were analyzed in order to supply the basic design parameters of the buffer. Based on these parameters the thermal and mechanical analysis of the near-field was carried out. Thermal-Hydraulic-Mechanical behavior of the disposal system was analyzed. The reference disposal system was proposed through the second year research. At the final third stage of the research, the Korean Reference disposal System including the engineered barrier, surface facilities, and underground facilities was proposed through the performance analysis of the disposal system.

  5. The Spallation Neutron Source RF Reference System

    CERN Document Server

    Piller, Maurice; Crofford, Mark; Doolittle, Lawrence; Ma, Hengjie

    2005-01-01

    The Spallation Neutron Source (SNS) RF Reference System includes the master oscillator (MO), local oscillator(LO) distribution, and Reference RF distribution systems. Coherent low noise Reference RF signals provide the ability to control the phase relationships between the fields in the front-end and linear accelerator (linac) RF cavity structures. The SNS RF Reference System requirements, implementation details, and performance are discussed.

  6. Positional reference system for ultraprecision machining

    International Nuclear Information System (INIS)

    Arnold, J.B.; Burleson, R.R.; Pardue, R.M.

    1982-01-01

    A stable positional reference system for use in improving the cutting tool-to-part contour position in numerical controlledmultiaxis metal turning machines is provided. The reference system employs a plurality of interferometers referenced to orthogonally disposed metering bars which are substantially isolated from machine strain induced position errors for monitoring the part and tool positions relative to the metering bars. A microprocessor-based control system is employed in conjunction with the plurality of position interferometers and part contour description data inputs to calculate error components for each axis of movement and output them to corresponding axis drives with appropriate scaling and error compensation. Real-time position control, operating in combination with the reference system, makes possible the positioning of the cutting points of a tool along a part locus with a substantially greater degree of accuracy than has been attained previously in the art by referencing and then monitoring only the tool motion relative to a reference position located on the machine base

  7. Positional reference system for ultraprecision machining

    Science.gov (United States)

    Arnold, J.B.; Burleson, R.R.; Pardue, R.M.

    1980-09-12

    A stable positional reference system for use in improving the cutting tool-to-part contour position in numerical controlled-multiaxis metal turning machines is provided. The reference system employs a plurality of interferometers referenced to orthogonally disposed metering bars which are substantially isolated from machine strain induced position errors for monitoring the part and tool positions relative to the metering bars. A microprocessor-based control system is employed in conjunction with the plurality of positions interferometers and part contour description data input to calculate error components for each axis of movement and output them to corresponding axis driven with appropriate scaling and error compensation. Real-time position control, operating in combination with the reference system, makes possible the positioning of the cutting points of a tool along a part locus with a substantially greater degree of accuracy than has been attained previously in the art by referencing and then monitoring only the tool motion relative to a reference position located on the machine base.

  8. 78 FR 18316 - Fresh Garlic From the People's Republic of China: Final Rescission of Antidumping Duty New...

    Science.gov (United States)

    2013-03-26

    ... DEPARTMENT OF COMMERCE International Trade Administration [A-570-831] Fresh Garlic From the People... reviews (NSRs) of the antidumping duty order on fresh garlic from the People's Republic of China (PRC) \\1... rescinding the NSRs of both Fuyi and Maycarrier. \\1\\ See Fresh Garlic From the People's Republic of China...

  9. Expert Systems in Reference Services.

    Science.gov (United States)

    Roysdon, Christine, Ed.; White, Howard D., Ed.

    1989-01-01

    Eleven articles introduce expert systems applications in library and information science, and present design and implementation issues of system development for reference services. Topics covered include knowledge based systems, prototype development, the use of artificial intelligence to remedy current system inadequacies, and an expert system to…

  10. Antares Reference Telescope System

    International Nuclear Information System (INIS)

    Viswanathan, V.K.; Kaprelian, E.; Swann, T.; Parker, J.; Wolfe, P.; Woodfin, G.; Knight, D.

    1983-01-01

    Antares is a 24-beam, 40-TW carbon-dioxide laser-fusion system currently nearing completion at the Los Alamos National Laboratory. The 24 beams will be focused onto a tiny target (typically 300 to 1000 μm in diameter) located approximately at the center of a 7.3-m-diameter by 9.3-m-long vacuum (10 - 6 torr) chamber. The design goal is to position the targets to within 10 μm of a selected nominal position, which may be anywhere within a fixed spherical region 1 cm in diameter. The Antares Reference Telescope System is intended to help achieve this goal for alignment and viewing of the various targets used in the laser system. The Antares Reference Telescope System consists of two similar electro-optical systems positioned in a near orthogonal manner in the target chamber area of the laser. Each of these consists of four subsystems: (1) a fixed 9X optical imaging subsystem which produces an image of the target at the vidicon; (2) a reticle projection subsystem which superimposes an image of the reticle pattern at the vidicon; (3) an adjustable front-lighting subsystem which illuminates the target; and (4) an adjustable back-lighting subsystem which also can be used to illuminate the target. The various optical, mechanical, and vidicon design considerations and trade-offs are discussed. The final system chosen (which is being built) and its current status are described in detail

  11. The CEBAF fiber optic phase reference system

    International Nuclear Information System (INIS)

    Crawford, K.; Simrock, S.; Hovater, C.; Krycuk, A.

    1995-01-01

    The specified phase stability of the CEBAF RF distribution system is 2.9 degree rms per linac. Stability is achieved through the use of a temperature and pressure regulated coaxial drive line. Purpose of the fiber optic phase reference system is to monitor the relative phase at the beginning and ending of this drive line, between linacs, injector and separator to determine drift due to ambient temperature fluctuations. The system utilizes an Ortel 1310 nm single mode laser driving Sumitumo optical fiber to distribute a reference signal at 1497 MHz. Phase of this reference signal is compared to the 1427 MHz (LO) and the 70 MHz (IF) via a 360 degree phase detector. The detected information is then routed to the CEBAF control system for display with a specified resolution of ±0.2 degree over a 20 degree phase delta

  12. On the invariance of world time reference system

    International Nuclear Information System (INIS)

    Asanov, G.S.

    1978-01-01

    A universal reference system is studied. It is shown that time differentiation acquires an invariant meaning in the covariant theory of a curved space-time. All the principal covariant equations of the Einstein gravitational field theory can be interpreted successively relative to a universal reference system, whose base congruence is the S-congruence. The Lorentz calibration conditions determine the base tetrades of the universal reference system with an accuracy to rigid spatial rotations with constant coefficients. The use of rigid tetrades eliminates the ambiguity in the interpretation of the value of the energy momentum of a gravitational field

  13. An N+3 Technology Level Reference Propulsion System

    Science.gov (United States)

    Jones, Scott M.; Haller, William J.; Tong, Michael To-Hing

    2017-01-01

    An N+3 technology level engine, suitable as a propulsion system for an advanced single-aisle transport, was developed as a reference cycle for use in technology assessment and decision-making efforts. This reference engine serves three main purposes: it provides thermodynamic quantities at each major engine station, it provides overall propulsion system performance data for vehicle designers to use in their analyses, and it can be used for comparison against other proposed N+3 technology-level propulsion systems on an equal basis. This reference cycle is meant to represent the expected capability of gas turbine engines in the N+3 timeframe given reasonable extrapolations of technology improvements and the ability to take full advantage of those improvements.

  14. Modcomp MAX IV System Processors reference guide

    Energy Technology Data Exchange (ETDEWEB)

    Cummings, J.

    1990-10-01

    A user almost always faces a big problem when having to learn to use a new computer system. The information necessary to use the system is often scattered throughout many different manuals. The user also faces the problem of extracting the information really needed from each manual. Very few computer vendors supply a single Users Guide or even a manual to help the new user locate the necessary manuals. Modcomp is no exception to this, Modcomp MAX IV requires that the user be familiar with the system file usage which adds to the problem. At General Atomics there is an ever increasing need for new users to learn how to use the Modcomp computers. This paper was written to provide a condensed Users Reference Guide'' for Modcomp computer users. This manual should be of value not only to new users but any users that are not Modcomp computer systems experts. This Users Reference Guide'' is intended to provided the basic information for the use of the various Modcomp System Processors necessary to, create, compile, link-edit, and catalog a program. Only the information necessary to provide the user with a basic understanding of the Systems Processors is included. This document provides enough information for the majority of programmers to use the Modcomp computers without having to refer to any other manuals. A lot of emphasis has been placed on the file description and usage for each of the System Processors. This allows the user to understand how Modcomp MAX IV does things rather than just learning the system commands.

  15. An Estimator for Attitude and Heading Reference Systems Based on Virtual Horizontal Reference

    DEFF Research Database (Denmark)

    Wang, Yunlong; Soltani, Mohsen; Hussain, Dil muhammed Akbar

    2016-01-01

    makes it possible to correct the output of roll and pitch of the attitude estimator in the situations without accelerometer measurements, which cannot be achieved by the conventional nonlinear attitude estimator. The performance of VHR is tested both in simulation and hardware environment to validate......The output of the attitude determination systems suffers from large errors in case of accelerometer malfunctions. In this paper, an attitude estimator, based on Virtual Horizontal Reference (VHR), is designed for an Attitude Heading and Reference System (AHRS) to cope with this problem. The VHR...... their estimation performance. Moreover, the hardware test results are compared with that of a high-precision commercial AHRS to verify the estimation results. The implemented algorithm has shown high accuracy of attitude estimation that makes the system suitable for many applications....

  16. 49 CFR 614.101 - Cross-reference to management systems.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 7 2010-10-01 2010-10-01 false Cross-reference to management systems. 614.101... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION TRANSPORTATION INFRASTRUCTURE MANAGEMENT § 614.101 Cross-reference to management systems. The regulations in 23 CFR Part 500, subparts A and B shall be followed in...

  17. Properties of gravi-inertial systems of reference

    International Nuclear Information System (INIS)

    Dozmorov, I.M.

    1977-01-01

    A number of papers of the author have been summarized devoted to gravi-inertial systems of reference in which the following problems are solved: a) analogs of inertial systems of reference (ISR), gravi-ISR, have been introduced into the general relativity the ory (GRT); b) using transformations between such ISR as symmetry transformation, obtained by variational methods are values with clear physical sense; c) using the gravi-ISR basis as the zero level of the deformation reading, the theory of elasticity in GRT has been constructed and someof its applications considered. The results are compared with those of other authors

  18. weHelp: A Reference Architecture for Social Recommender Systems.

    Science.gov (United States)

    Sheth, Swapneel; Arora, Nipun; Murphy, Christian; Kaiser, Gail

    2010-01-01

    Recommender systems have become increasingly popular. Most of the research on recommender systems has focused on recommendation algorithms. There has been relatively little research, however, in the area of generalized system architectures for recommendation systems. In this paper, we introduce weHelp : a reference architecture for social recommender systems - systems where recommendations are derived automatically from the aggregate of logged activities conducted by the system's users. Our architecture is designed to be application and domain agnostic. We feel that a good reference architecture will make designing a recommendation system easier; in particular, weHelp aims to provide a practical design template to help developers design their own well-modularized systems.

  19. Standard Relativistic Reference Systems and the IAU Framework

    Science.gov (United States)

    Soffel, Michael H.

    2009-05-01

    The classical post-Newtonian (PN) framework is formulated in one single reference system. In a series of papers Damour, Soffel and Xu laid the foundations for a new improved PN framework dealing with the celestial mechanical problem of N gravitationally interacting rotating bodies of arbitrary shape and the problem of astronomical reference systems. In the DSX-framework a total of N+1 reference systems with corresponding coordinates is introduced in the N-body problem: a global one covering the entire model manifold where the translational equations of motion are formulated and one local system attached to each of the N bodies that is co-moving with the body under consideration. In each of these systems the metric tensor is assumed to be of a special form determined by two potentials: a scalar and a vector potential. Theorems are given for the transformations between local and global coordinates and metric potentials. In each of the local systems outside the local body the metric potentials are expressed in terms of Blanchet-Damour mass- and spin-multipole moments. The talk first introduces the original DSX formalism and then concentrates on IAU resolutions related with it. Finally, the formalism is extended to include also effects from the cosmic expansion. The influence of the Hubble expansion on the dynamics of the solar system is explicitly discussed in some detail.

  20. Light-water reactors reference system classification for the European reliability data system (ERDS)

    International Nuclear Information System (INIS)

    Melis, M.; Mancini, G.

    1982-01-01

    The reference system classification represents a basic stage in the organization of the European reliability data system (ERDS) for light-water reactors, a project actually in development at the Joint Research Centre, Ispra. This project is concerned with operational reliability data collection from the various ''national'' data banks, and centralization in a European reliability data system, so improving the significance of the resulting reliability evaluations. In the framework of the ERDS project, the reference system classification provides a LWR functional break-down and represents a plant-unique identification in the process of homogenization of event-data coming from the various ''national'' organizations. The report, after a brief description of the main objectives of the ERDS project, reviews the criteria followed in the elaboration of the reference system classification; then the detailed classification is presented. The nuclear power station is subdivided in about 180 systems. To each system a sheet is associated, containing: a comprehensive description of system-functions and boundaries; a descritpion of the plant operating mode, linked to the various system functions; a list of the main interface system; and finally, a list of the main components, including type and safety classification

  1. Crew Transportation System Design Reference Missions

    Science.gov (United States)

    Mango, Edward J.

    2015-01-01

    Contains summaries of potential design reference mission goals for systems to transport humans to andfrom low Earth orbit (LEO) for the Commercial Crew Program. The purpose of this document is to describe Design Reference Missions (DRMs) representative of the end-to-end Crew Transportation System (CTS) framework envisioned to successfully execute commercial crew transportation to orbital destinations. The initial CTS architecture will likely be optimized to support NASA crew and NASA-sponsored crew rotation missions to the ISS, but consideration may be given in this design phase to allow for modifications in order to accomplish other commercial missions in the future. With the exception of NASA’s mission to the ISS, the remaining commercial DRMs are notional. Any decision to design or scar the CTS for these additional non-NASA missions is completely up to the Commercial Provider. As NASA’s mission needs evolve over time, this document will be periodically updated to reflect those needs.

  2. Sourcebook for energy assessment. [Reference Energy Systems for 1972-2020

    Energy Technology Data Exchange (ETDEWEB)

    Beller, M. (ed.)

    1975-12-01

    An analytical approach is presented that is broadly applicable to the assessment of energy technologies and policies. Using the Reference Energy System approach, it permits the examination of the economic, environmental, and resource implications resulting from the substitution of one fuel or technology for another. Included as tools for such analyses are the necessary data and methodology, as well as a set of Reference Energy Systems covering the 1972-2020 period to serve as baselines for the perturbation analyses of interest. 46 tables, 25 figures, 71 references.

  3. Developing a Frame of Reference for understanding configuration systems

    DEFF Research Database (Denmark)

    Ladeby, Klaes Rohde; Edwards, Kasper

    2008-01-01

    This paper uses the theory of technical systems to develop a frame of reference of product configuration systems. Following a definition of the configuration task, product model and product configuration system the theory of technical systems are presented. Configuration systems are then related...

  4. Astronomical relativistic reference systems with multipolar expansion: the global one

    International Nuclear Information System (INIS)

    Xie Yi

    2014-01-01

    With the rapid development of techniques for astronomical observations, the precision of measurements has been significantly increasing. Theories describing astronomical relativistic reference systems, which are the foundation for processing and interpreting these data now and in the future, may require extensions to satisfy the needs of these trends. Besides building a framework compatible with alternative theories of gravity and the pursuit of higher order post-Newtonian approximation, it will also be necessary to make the first order post-Newtonian multipole moments of celestial bodies be explicitly expressed in the astronomical relativistic reference systems. This will bring some convenience into modeling the observations and experiments and make it easier to distinguish different contributions in measurements. As a first step, the global solar system reference system is expressed as a multipolar expansion and the post-Newtonian mass and spin moments are shown explicitly in the metric which describes the coordinates of the system. The full expression of the global metric is given. (research papers)

  5. Data Link Test and Analysis System/ATCRBS Transponder Test System Technical Reference

    Science.gov (United States)

    1990-05-01

    This document references material for personnel using or making software changes : to the Data Link Test and Analysis System (DATAS) for Air Traffic Control Radar : Beacon System (ATCRBS) transponder testing and data collection. This is one of : a se...

  6. Discrete Model Reference Adaptive Control System for Automatic Profiling Machine

    Directory of Open Access Journals (Sweden)

    Peng Song

    2012-01-01

    Full Text Available Automatic profiling machine is a movement system that has a high degree of parameter variation and high frequency of transient process, and it requires an accurate control in time. In this paper, the discrete model reference adaptive control system of automatic profiling machine is discussed. Firstly, the model of automatic profiling machine is presented according to the parameters of DC motor. Then the design of the discrete model reference adaptive control is proposed, and the control rules are proven. The results of simulation show that adaptive control system has favorable dynamic performances.

  7. A Reference Architecture for Network-Centric Information Systems

    National Research Council Canada - National Science Library

    Renner, Scott; Schaefer, Ronald

    2003-01-01

    This paper presents the "C2 Enterprise Reference Architecture" (C2ERA), which is a new technical concept of operations for building information systems better suited to the Network-Centric Warfare (NCW) environment...

  8. SNAP operating system reference manual

    International Nuclear Information System (INIS)

    Sabuda, J.D.; Polito, J.; Walker, J.L.; Grant, F.H. III.

    1982-03-01

    The SNAP Operating System (SOS) is a FORTRAN 77 program which provides assistance to the safeguards analyst who uses the Safeguards Automated Facility Evaluation (SAFE) and the Safeguards Network Analysis Procedure (SNAP) techniques. Features offered by SOS are a data base system for storing a library of SNAP applications, computer graphics representation of SNAP models, a computer graphics editor to develop and modify SNAP models, a SAFE-to-SNAP interface, automatic generation of SNAP input data, and a computer graphic post-processor for SNAP. The SOS Reference Manual provides detailed application information concerning SOS as well as a detailed discussion of all SOS components and their associated command input formats. SOS was developed for the US Nuclear Regulatory Commission's Office of Nuclear Regulatory Research and the US Naval Surface Weapons Center by Pritsker and Associates, Inc., under contract to Sandia National Laboratories

  9. A reference model for space data system interconnection services

    Science.gov (United States)

    Pietras, John; Theis, Gerhard

    1993-01-01

    The widespread adoption of standard packet-based data communication protocols and services for spaceflight missions provides the foundation for other standard space data handling services. These space data handling services can be defined as increasingly sophisticated processing of data or information received from lower-level services, using a layering approach made famous in the International Organization for Standardization (ISO) Open System Interconnection Reference Model (OSI-RM). The Space Data System Interconnection Reference Model (SDSI-RM) incorporates the conventions of the OSIRM to provide a framework within which a complete set of space data handling services can be defined. The use of the SDSI-RM is illustrated through its application to data handling services and protocols that have been defined by, or are under consideration by, the Consultative Committee for Space Data Systems (CCSDS).

  10. Reference clock parameters for digital communications systems applications

    Science.gov (United States)

    Kartaschoff, P.

    1981-01-01

    The basic parameters relevant to the design of network timing systems describe the random and systematic time departures of the system elements, i.e., master (or reference) clocks, transmission links, and other clocks controlled over the links. The quantitative relations between these parameters were established and illustrated by means of numerical examples based on available measured data. The examples were limited to a simple PLL control system but the analysis can eventually be applied to more sophisticated systems at the cost of increased computational effort.

  11. Hazardous Solvent Substitution Data System reference manual

    International Nuclear Information System (INIS)

    Branham-Haar, K.A.; Twitchell, K.E.

    1993-07-01

    Concern for the environment, in addition to Federal regulation, mandate the replacement of hazardous solvents with safer cleaning agents. Manufacturers are working to produce these replacement solvents. As these products are developed, potential users need to be informed of their availability. To promote the use of these new products instead of traditional solvents, the Idaho National Engineering Laboratory (INEL) has developed the Hazardous Solvent Substitution Data System (HSSDS). The HSSDS provides a comprehensive system of information on alternatives to hazardous solvents and related subjects, and it makes that information available to solvent users, industrial hygienists, and process engineers. The HSSDS uses TOPIC reg-sign, a text retrieval system produced by Verity, Inc., to allow a user to search for information on a particular subject. TOPIC reg-sign produces a listing of the retrieved documents and allows the use to examine the documents individually and to use the information contained in them. This reference manual does not replace the comprehensive TOPIC reg-sign user documentation (available from Verity, Inc.), or the HSSDS Tutorial (available from the INEL). The purpose of this reference manual is to provide enough instruction on TOPIC reg-sign so the user may begin accessing the data contained in the HSSDS

  12. Mobile User Objective Systems (MUOS) Reference Implementation Laboratory (MRIL)

    Data.gov (United States)

    Federal Laboratory Consortium — The Mobile User Objective Systems (MUOS) Reference Implementation Laboratory (MRIL) performs verification and validation testing of various MUOS terminals. MRIL also...

  13. Status of NGS CORS Network and Its Contribution to the GGOS Infrastructure

    Science.gov (United States)

    Choi, K. K.; Haw, D.; Sun, L.

    2017-12-01

    Recent advancement of Satellite Geodesy techniques can now contribute to the global frame realization needed to improve worldwide accuracies. These techniques rely on coordinates computed using continuously observed GPS data and corresponding satellite orbits. The GPS-based reference system continues to depend on the physical stability of a ground-based network of points as the primary foundation for these observations. NOAA's National Geodetic Survey (NGS) has been operating Continuously Operating Reference Stations (CORS) to provide direct access to the National Spatial Reference System (NSRS). By virtue of NGS' scientific reputation and leadership in national and international geospatial issues, NGS has determined to increase its participation in the maintenance of the U.S. component of the global GPS tracking network in order to realize a long-term stable national terrestrial reference frame. NGS can do so by leveraging its national leadership role coupled with NGS' scientific expertise, in designating and upgrading a subset of the current tracking network for this purpose. This subset of stations must have the highest operational standards to serve the dual functions: being the U.S. contribution to the international frame, along with providing the link to the national datum. These stations deserve special attention to ensure that the highest possible levels of quality and stability are maintained. To meet this need, NGS is working with the international scientific groups to add and designate these reference stations based on scientific merit such as: colocation with other geodetic techniques, geographic area, and monumentation stability.

  14. On Chinese National Continuous Operating Reference Station System of GNSS

    Directory of Open Access Journals (Sweden)

    CHEN Junyong

    2007-11-01

    Full Text Available Objective: Global navigation satellite system (GNSS Continuous Operating Reference Station (CORS System can maintain a accurate, 3D, geocentric and dynamic reference coordinate frame in the corresponding area, can provide positioning and navigation service. It can also serve for the meteorology, geodynamics, earthquake monitoring and Location Based services (LBS etc in the same area. Until now, our country can’t provide a facing National CORS System serving for every profession and trade, and the national sharing platform of CORS System resources has not been established. So this paper discusses some valuable insight how to construct the National CORS System in China. Method: Constructing goal、Service object、CORS distribution、CORS geographic、geology and communication environment and other factors, are major considerations for the Constructing the National CORS System. Moreover, constructing GNSS CORS is more specific, mainly from four aspects, namely site-selection、civil construction、security measures and equipment-selection for consideration. Outcome: The project of the Constructing Global navigation satellite system (GNSS Continuous Operating Reference Station (CORS System in china is put forward, and is discussed from goal、principle、project and other for construction. Some meaning thought how to construct the National CORS System is submitted Conclusion: The Global navigation satellite system (GNSS Continuous Operating Reference Station (CORS System in china is the lack of a unified planning and design in the national level. So far, the national CORS system serving all walks of life has not been provided, and the national sharing platform of CORS System resources has not been established The primary mission of the Global navigation satellite system (GNSS Continuous Operating Reference Station (CORS System in china is as follows: using data set of GNSS and receiving, transport, process, integration, transmit information and

  15. On the theory of transformations of coordinates for massive systems of reference

    International Nuclear Information System (INIS)

    Sadykov, B.S.

    1978-01-01

    Suggested is a new local group of coordinate transformations of reference systems connected with massive bodies, such as the Earth, the Sun and so on, which are rather inertial in the kinematic relation, but possess different gravitational fields. The effect of the gravitational field of the reference body upon the metric of the system is taken into account. For identical systems the new group transfers into the Lorentz group

  16. Reference dosimeter system of the IAEA

    International Nuclear Information System (INIS)

    Mehta, Kishor; Girzikowsky, Reinhard

    1995-01-01

    Quality assurance programmes must be in operation at radiation facilities to satisfy national and international Standards. Since dosimetry has a vital function in these QA programmes, it is imperative that the dosimetry systems in use at these facilities are well calibrated with a traceability to a Primary Standard Dosimetry Laboratory. As a service to the Member States, the International Atomic Energy Agency operates the International Dose Assurance Service (IDAS) to assist in this process. The transfer standard dosimetry system that is used for this service is based on ESR spectrometry. The paper describes the activities undertaken at the IAEA Dosimetry Laboratory to establish the QA programme for its reference dosimetry system. There are four key elements of such a programme: quality assurance manual; calibration that is traceable to a Primary Standard Dosimetry Laboratory; a clear and detailed statement of uncertainty in the dose measurement; and, periodic quality audit. (Author)

  17. Reference dosimeter system of the iaea

    Science.gov (United States)

    Mehta, Kishor; Girzikowsky, Reinhard

    1995-09-01

    Quality assurance programmes must be in operation at radiation processing facilities to satisfy national and international Standards. Since dosimetry has a vital function in these QA programmes, it is imperative that the dosimetry systems in use at these facilities are well calibrated with a traceability to a Primary Standard Dosimetry Laboratory. As a service to the Member States, the International Atomic Energy Agency operates the International Dose Assurance Service (IDAS) to assist in this process. The transfer standard dosimetry system that is used for this service is based on ESR spectrometry. The paper describes the activities undertaken at the IAEA Dosimetry Laboratory to establish the QA programme for its reference dosimetry system. There are four key elements of such a programme: quality assurance manual; calibration that is traceable to a Primary Standard Dosimetry Laboratory; a clear and detailed statement of uncertainty in the dose measurement; and, periodic quality audit.

  18. Reference dosimeter system of the IAEA

    International Nuclear Information System (INIS)

    Mehta, K.; Girzikowsky, R.

    1995-01-01

    Quality assurance programmes must be in operation at radiation processing facilities to satisfy national and international standards. Since dosimetry has a vital function in these QA programmes, it is imperative that the dosimetry systems in use at these facilities are well calibrated with a traceability to a Primary Standard Dosimetry Laboratory. As a service to the Member States, the International Atomic Energy Agency operates the International Dose Assurance Service (IDAS) to assist in this process. The transfer standard dosimetry system that is used for this service is based on ESR spectrometry. The paper describes the activities undertaken at the IAEA Dosimetry Laboratory to establish the QA programme for its reference dosimetry system. There are four key elements of such a programme: quality assurance manual; calibration that is traceable to a Primary Standard Dosimetry Laboratory; a clear and detailed statement of uncertainty in the dose measurement; and, periodic quality audit. (author)

  19. Direct writing of sub-wavelength ripples on silicon using femtosecond laser at high repetition rate

    International Nuclear Information System (INIS)

    Xie, Changxin; Li, Xiaohong; Liu, Kaijun; Zhu, Min; Qiu, Rong; Zhou, Qiang

    2016-01-01

    Graphical abstract: - Highlights: • The NSRs and DSRs are obtained on silicon surface. • With increasing direct writing speed, the NSRs suddenly changes and becomes the DSRs. • We develop a Sipe–Drude interference theory by considering the thermal excitation. - Abstract: The near sub-wavelength and deep sub-wavelength ripples on monocrystalline silicon were formed in air by using linearly polarized and high repetition rate femtosecond laser pulses (f = 76 MHz, λ = 800 nm, τ = 50 fs). The effects of laser pulse energy, direct writing speed and laser polarization on silicon surface morphology are studied. When the laser pulse energy is 2 nJ/pulse and the direct writing speed varies from 10 to 25 mm/s, the near sub-wavelength ripples (NSRs) with orientation perpendicular to the laser polarization are generated. While the direct writing speed reaches 30 mm/s, the direction of the obtained deep sub-wavelength ripples (DSRs) suddenly changes and becomes parallel to the laser polarization, rarely reported so far for femtosecond laser irradiation of silicon. Meanwhile, we extend the Sipe–Drude interference theory by considering the thermal excitation, and numerically calculate the efficacy factor for silicon irradiated by femtosecond laser pulses. The revised Sipe–Drude interference theoretical results show good agreement with the periods and orientations of sub-wavelength ripples.

  20. Environmental systems analysis of biogas systems-Part II: The environmental impact of replacing various reference systems

    International Nuclear Information System (INIS)

    Boerjesson, Pal; Berglund, Maria

    2007-01-01

    This paper analyses the overall environmental impact when biogas systems are introduced and replace various reference systems for energy generation, waste management and agricultural production. The analyses are based on Swedish conditions using a life-cycle perspective. The biogas systems included are based on different combinations of raw materials and final use of the biogas produced (heat, power and transportation fuel). A general conclusion is that biogas systems normally lead to environmental improvements, which in some cases are considerable. This is often due to indirect environmental benefits of changed land use and handling of organic waste products (e.g. reduced nitrogen leaching, emissions of ammonia and methane), which often exceed the direct environmental benefits achieved when fossil fuels are replaced by biogas (e.g. reduced emissions of carbon dioxide and air pollutants). Such indirect benefits are seldom considered when biogas is evaluated from an environmental point of view. The environmental impact from different biogas systems can, however, vary significantly due to factors such as the raw materials utilised, energy service provided and reference system replaced

  1. Performance evaluation of the Antares Reference Telescope System

    International Nuclear Information System (INIS)

    Parker, J.R.; Woodfin, G.L.; Viswanathan, V.K.

    1985-01-01

    The Antares Reference Telescope System is a complicated electro-optical-mechanical system whose main purpose is to enable positioning of targets used in the Antares Laser System to within 10 μm of a selected nominal position. To date, it has been used successfully to position targets ranging in size from 300 μm to 2 mm. The system consists of two electro-optical systems positioned in a nearly orthogonal manner. This ''cross telescope'' configuration facilitates accurate positioning in three planes. The results obtained so far in resolution and positioning of targets using this system are discussed. It is shown that a resolution of 200 lp/mm and a positioning precision of 25 μm can be obtained

  2. Speed Sensorless Control of PMSM using Model Reference Adaptive System and RBFN

    OpenAIRE

    Wei Gao; Zhirong Guo

    2013-01-01

    In the speed sensorless vector control system, the amended method of estimating the rotor speed about model reference adaptive system (MRAS) based on radial basis function neural network (RBFN) for PMSM sensorless vector control system was presented. Based on the PI regulator, the radial basis function neural network which is more prominent learning efficiency and performance is combined with MRAS. The reference model and the adjust model are the PMSM itself and the PMSM current, respectively...

  3. Activity Management System user reference manual. Revision 1

    International Nuclear Information System (INIS)

    Gates, T.A.; Burdick, M.B.

    1994-01-01

    The Activity Management System (AMS) was developed in response to the need for a simple-to-use, low-cost, user interface system for collecting and logging Hanford Waste Vitrification Plant Project (HWVP) activities. This system needed to run on user workstations and provide common user access to a database stored on a local network file server. Most important, users wanted a system that provided a management tool that supported their individual process for completing activities. Existing system treated the performer as a tool of the system. All AMS data is maintained in encrypted format. Users can feel confident that any activities they have entered into the database are private and that, as the originator, they retain sole control over who can see them. Once entered into the AMS database, the activities cannot be accessed by anyone other than the originator, the designated agent, or by authorized viewers who have been explicitly granted the right to look at specific activities by the originator. This user guide is intended to assist new AMS users in learning how to use the application and, after the initial learning process, will serve as an ongoing reference for experienced users in performing infrequently used functions. Online help screens provide reference to some of the key information in this manual. Additional help screens, encompassing all the applicable material in this manual, will be incorporated into future AMS revisions. A third, and most important, source of help is the AMS administrator(s). This guide describes the initial production version of AMS, which has been designated Revision 1.0

  4. [Breastfeeding and the anthropometric profile of children with sickle cell anemia receiving follow-up in a newborn screening reference service].

    Science.gov (United States)

    Nogueira, Zeni Drubi; Boa-Sorte, Ney; Leite, Maria Efigênia de Queiroz; Kiya, Márcia Miyuki; Amorim, Tatiana; Fonseca, Silvana Fahel da

    2015-01-01

    To study breastfeeding history (BF) and the anthropometric status of children with Sickle Cell Disease (SCD). A cross-sectional study of 357 children with SS and SC hemoglobinopathies aged between 2 and 6 years old receiving regular follow-up at a Newborn Screening Reference Service (NSRS) between November 2007 and January 2009. The outcome was anthropometric status and the exposures were: BF pattern, type of hemoglobinopathy and child's age and sex. The average (SD) age was 3.7 (1.1) years, 52.9% were boys and 53.5% had SS hemoglobinopathy. The prevalence of exclusive breastfeeding (EBR) up to six months of age was 31.5%, the median EBR times (p25-p75) was 90.0 (24.0-180.0) days and the median weaning ages (p25-p75) was 360.0 (90.0-20.0) days respectively. Normal W/H children experienced EBR for an average duration almost four times longer than malnourished children (p=0.01), and were weaned later (p<0.05). Height deficit was found in 5.0% of children, while all the children with severe short stature had SS hemoglobinopathy and were over 4 years of age. EBR time and weaning age were greater than found in the literature, which is a possible effect of the multidisciplinary follow-up. Duration of EBR and later weaning were associated with improved anthropometric indicators. Copyright © 2014 Associação de Pediatria de São Paulo. Publicado por Elsevier Editora Ltda. All rights reserved.

  5. MATHEMATICAL MODEL OF TRIAXIAL MULTIMODE ATTITUDE AND HEADING REFERENCE SYSTEM

    Directory of Open Access Journals (Sweden)

    Olha Sushchenko

    2017-07-01

    Full Text Available Purpose: The paper deals with the mathematical description of the gimballed attitude and heading reference systems, which can be applied in design of strategic precision navigation systems. The main goal is to created mathematical description taking into consideration the necessity to use different navigations operating modes of this class of navigation systems. To provide the high accuracy the indirect control is used when the position of the gimballed platform is controlled by signals of gyroscopic devices, which are corrected using accelerometer’s signals. Methods: To solve the given problem the methods of the classical theoretical mechanics, gyro theory, and inertial navigation are used. Results: The full mathematical model of the gimballed attitude and heading reference system is derived including descriptions of different operating modes. The mathematical models of the system Expressions for control and correction moments in the different modes are represented. The simulation results are given. Conclusions: The represented results prove efficiency of the proposed models. Developed mathematical models can be useful for design of navigation systems of the wide class of moving vehicles.

  6. Nuclear thermal rocket workshop reference system Rover/NERVA

    International Nuclear Information System (INIS)

    Borowski, S.K.

    1991-01-01

    The Rover/NERVA engine system is to be used as a reference, against which each of the other concepts presented in the workshop will be compared. The following topics are reviewed: the operational characteristics of the nuclear thermal rocket (NTR); the accomplishments of the Rover/NERVA programs; and performance characteristics of the NERVA-type systems for both Mars and lunar mission applications. Also, the issues of ground testing, NTR safety, NASA's nuclear propulsion project plans, and NTR development cost estimates are briefly discussed

  7. An implicit adaptation algorithm for a linear model reference control system

    Science.gov (United States)

    Mabius, L.; Kaufman, H.

    1975-01-01

    This paper presents a stable implicit adaptation algorithm for model reference control. The constraints for stability are found using Lyapunov's second method and do not depend on perfect model following between the system and the reference model. Methods are proposed for satisfying these constraints without estimating the parameters on which the constraints depend.

  8. Reference material systems: a sourcebook for material assessment

    Energy Technology Data Exchange (ETDEWEB)

    Bhagat, N. (ed.)

    1976-12-01

    A reference set of data related to material systems and a framework for carrying out the material technologies assessment are presented. While the bulk of renewables have been considered in this report, the nonrenewable materials dealt with here include structural materials only, such as steel, aluminum, cement and concrete, and bricks. The complete data set is supposed to include material flows, energy requirements, capital and labor inputs, and environmental effects for each process that a resource must go through to become a useful material for an end use. Although effort has been made to obtain as much information as possible, considerable gaps in data, apparent throughout this report, could not be avoided. A new material technology can be evaluated by substituting that technology for appropriate elements of the reference materials system and calculating the net change in material resource, energy, capital and labor requirements, and environmental impacts. This combination of information thus serves as a means of evaluating the potential benefits to be gained by research in various material technologies.

  9. A reference system for animal biometrics: application to the northern leopard frog

    Science.gov (United States)

    Petrovska-Delacretaz, D.; Edwards, A.; Chiasson, J.; Chollet, G.; Pilliod, D.S.

    2014-01-01

    Reference systems and public databases are available for human biometrics, but to our knowledge nothing is available for animal biometrics. This is surprising because animals are not required to give their agreement to be in a database. This paper proposes a reference system and database for the northern leopard frog (Lithobates pipiens). Both are available for reproducible experiments. Results of both open set and closed set experiments are given.

  10. Referring to IAEA system to improve Chinese standards system on nuclear and radiation safety

    International Nuclear Information System (INIS)

    Shang Zhaorong; Wang Wenhai

    2010-01-01

    Referring to the standards system of IAEA, to build and improve the Chinese standards system of nuclear and radiation safety is a long term infrastructure work and an assurance to keep sustainable development of nuclear industry and nuclear technology application in China. The paper analyses the current main problem, and gives some suggestions on developing and improving the system. (authors)

  11. Testing and reference model analysis of FTTH system

    Science.gov (United States)

    Feng, Xiancheng; Cui, Wanlong; Chen, Ying

    2009-08-01

    With rapid development of Internet and broadband access network, the technologies of xDSL, FTTx+LAN , WLAN have more applications, new network service emerges in endless stream, especially the increase of network game, meeting TV, video on demand, etc. FTTH supports all present and future service with enormous bandwidth, including traditional telecommunication service, traditional data service and traditional TV service, and the future digital TV and VOD. With huge bandwidth of FTTH, it wins the final solution of broadband network, becomes the final goal of development of optical access network.. Fiber to the Home (FTTH) will be the goal of telecommunications cable broadband access. In accordance with the development trend of telecommunication services, to enhance the capacity of integrated access network, to achieve triple-play (voice, data, image), based on the existing optical Fiber to the curb (FTTC), Fiber To The Zone (FTTZ), Fiber to the Building (FTTB) user optical cable network, the optical fiber can extend to the FTTH system of end-user by using EPON technology. The article first introduced the basic components of FTTH system; and then explain the reference model and reference point for testing of the FTTH system; Finally, by testing connection diagram, the testing process, expected results, primarily analyze SNI Interface Testing, PON interface testing, Ethernet performance testing, UNI interface testing, Ethernet functional testing, PON functional testing, equipment functional testing, telephone functional testing, operational support capability testing and so on testing of FTTH system. ...

  12. The disposal of Canada's nuclear fuel waste: postclosure assessment of a reference system

    International Nuclear Information System (INIS)

    Goodwin, B.W.; McConnell, D.B.; Andres, T.H.

    1994-01-01

    The concept for disposal of Canada's nuclear fuel waste is based on a vault located deep in plutonic rock of the Canadian Shield. We document in this report a method to assess the long-term impacts of a disposal facility for nuclear fuel waste. The assessment integrates relevant information from engineering design studies, site investigations, laboratory studies, expert judgment and detailed mathematical analyses to evaluate system performance in terms of safety criteria, guidelines and standards. The method includes the use of quantitative tools such as the Systems Variability Analysis computer Code (SYVAC) to deal with parameter uncertainty and the use of reasoned arguments based on well-established scientific principles. We also document the utility of the method by describing its application to a hypothetical implementation of the concept called the reference disposal system. The reference disposal system generally conforms to the overall characteristics of the concept, except we have made some specific site and design choices so that the assessment would be more realistic. To make the reference system more representative of a real system, we have used the geological observations of the AECL's Whiteshell Research Area located near Lac du Bonnet, Manitoba, to define the characteristics of the geosphere and the groundwater flow system. This research area has been subject to more than a decade of geological and hydrological studies. The analysis of the reference disposal system provides estimates of radiological and chemical toxicity impacts on members of a critical group and estimates of possible impacts on the environment. The latter impacts include estimates of radiation dose to nonhuman organisms. Other quantitative analyses examine the use of derived constraints to improve the margin of safety, the effectiveness of engineered and natural barriers, and the sensitivity of the results to influential features, events, and processes of the reference disposal

  13. RF Phase Reference Distribution System for the TESLA Technology Based Projects

    CERN Document Server

    Czuba, K; Romaniuk, R S

    2013-01-01

    Since many decades physicists have been building particle accelerators and usually new projects became more advanced, more complicated and larger than predecessors. The importance and complexity of the phase reference distribution systems used in these accelerators have grown significantly during recent years. Amongst the most advanced of currently developed accelerators are projects based on the TESLA technology. These projects require synchronization of many RF devices with accuracy reaching femtosecond levels over kilometre distances. Design of a phase reference distribution system fulfilling such requirements is a challenging scientific task. There are many interdisciplinary problems which must be solved during the system design. Many, usually negligible issues, may became very important in such system. Furthermore, the design of a distribution system on a scale required for the TESLA technology based projects is a new challenge and there is almost no literature sufficiently covering this subject. This th...

  14. The Necessity of Real-Time: Fact and Fiction in Digital Reference Systems.

    Science.gov (United States)

    Lankes, R. David; Shostack, Pauline

    2002-01-01

    Discussion of digital reference services and the use of real-time versus asynchronous services such as email focuses on data from the AskERIC digital reference service to demonstrate that asynchronous services are not only useful but may have greater utility than real-time systems. (Author/LRW)

  15. Digital Receiver Design for Transmitted Reference Ultra-Wideband Systems

    NARCIS (Netherlands)

    Wang, Y.; Leus, G.; Van der Veen, A.J.

    2009-01-01

    A complete detection, channel estimation, synchronization, and equalization scheme for a transmitted reference (TR) ultra-wideband (UWB) system is proposed in this paper. The scheme is based on a data model which admits a moderate data rate and takes both the interframe interference (IFI) and the

  16. Climate mitigation comparison of woody biomass systems with the inclusion of land-use in the reference fossil system

    International Nuclear Information System (INIS)

    Haus, S.; Gustavsson, L.; Sathre, R.

    2014-01-01

    While issues of land-use have been considered in many direct analyses of biomass systems, little attention has heretofore been paid to land-use in reference fossil systems. Here we address this limitation by comparing forest biomass systems to reference fossil systems with explicit consideration of land-use in both systems. We estimate and compare the time profiles of greenhouse gas (GHG) emission and cumulative radiative forcing (CRF) of woody biomass systems and reference fossil systems. A life cycle perspective is used that includes all significant elements of both systems, including GHG emissions along the full material and energy chains. We consider the growth dynamics of forests under different management regimes, as well as energy and material substitution effects of harvested biomass. We determine the annual net emissions of CO 2 , N 2 O and CH 4 for each system over a 240-year period, and then calculate time profiles of CRF as a proxy measurement of climate change impact. The results show greatest potential for climate change mitigation when intensive forest management is applied in the woody biomass system. This methodological framework provides a tool to help determine optimal strategies for managing forests so as to minimize climate change impacts. The inclusion of land-use in the reference system improves the accuracy of quantitative projections of climate benefits of biomass-based systems. - Highlights: • We analyze the dynamics of GHG emissions from woody biomass and fossil systems. • With a life cycle perspective, we account for forest land-use in both systems. • Replacing more carbon intensive fossil fuels gives greater climate benefit. • Increasing the intensity of forest management gives greater climate benefit. • Methodological choices in defining temporal system boundaries are important

  17. Nouns referring to tools and natural objects differentially modulate the motor system.

    Science.gov (United States)

    Gough, Patricia M; Riggio, Lucia; Chersi, Fabian; Sato, Marc; Fogassi, Leonardo; Buccino, Giovanni

    2012-01-01

    While increasing evidence points to a critical role for the motor system in language processing, the focus of previous work has been on the linguistic category of verbs. Here we tested whether nouns are effective in modulating the motor system and further whether different kinds of nouns - those referring to artifacts or natural items, and items that are graspable or ungraspable - would differentially modulate the system. A Transcranial Magnetic Stimulation (TMS) study was carried out to compare modulation of the motor system when subjects read nouns referring to objects which are Artificial or Natural and which are Graspable or Ungraspable. TMS was applied to the primary motor cortex representation of the first dorsal interosseous (FDI) muscle of the right hand at 150 ms after noun presentation. Analyses of Motor Evoked Potentials (MEPs) revealed that across the duration of the task, nouns referring to graspable artifacts (tools) were associated with significantly greater MEP areas. Analyses of the initial presentation of items revealed a main effect of graspability. The findings are in line with an embodied view of nouns, with MEP measures modulated according to whether nouns referred to natural objects or artifacts (tools), confirming tools as a special class of items in motor terms. Additionally our data support a difference for graspable versus non graspable objects, an effect which for natural objects is restricted to initial presentation of items. Copyright © 2011 Elsevier Ltd. All rights reserved.

  18. Decision support systems in nuclear emergencies: harmonizing domestic and reference tools

    International Nuclear Information System (INIS)

    Vamanu, D.; Mateescu, Gh.; Berinde, A.; Slavnicu, D.; Acasandrei, V.; Slavnicu, E.

    2001-01-01

    The paper addresses the issue of securing the compatibility and inter-operability of computer packages designed to perform as decision support tools in the management of radiological emergencies, over the transition times towards the implementation and uniform acceptance and uniform acceptance of internationally-shared reference tools such as the European Union's RODOS (Real Time On-Line Decision Support System for Off-Site Nuclear Emergencies in Europe). One submits that a harmonization between the currently operational, domestic, and the reference tool can be contemplated, based on extensive code comparison and benchmarking. A case in point is presented, paralleling selected RODOS applications on simulated abnormal nuclear events, and the concurrent application of a resident software package, NOTEPAD, developed to emulate RODOS-wise function at IFIH-HH Bucharest. The reproducible similarity may make domestic decision support system (DSS) facilities useful as both practical tools and factors promoting the emergency preparedness awareness, during the interim time laps till the full development and deployment of RODOS as a reference DSS in Europe. (authors)

  19. The MADE reference information model for interoperable pervasive telemedicine systems

    NARCIS (Netherlands)

    Fung, L.S.N.; Jones, Valerie M.; Hermens, Hermanus J.

    2017-01-01

    Objectives: The main objective is to develop and validate a reference information model (RIM) to support semantic interoperability of pervasive telemedicine systems. The RIM is one component within a larger, computer-interpretable "MADE language" developed by the authors in the context of the

  20. Camera Calibration of Stereo Photogrammetric System with One-Dimensional Optical Reference Bar

    International Nuclear Information System (INIS)

    Xu, Q Y; Ye, D; Che, R S; Qi, X; Huang, Y

    2006-01-01

    To carry out the precise measurement of large-scale complex workpieces, accurately calibration of the stereo photogrammetric system has becoming more and more important. This paper proposed a flexible and reliable camera calibration of stereo photogrammetric system based on quaternion with one-dimensional optical reference bar, which has three small collinear infrared LED marks and the lengths between these marks have been precisely calibration. By moving the optical reference bar at a number of locations/orientations over the measurement volume, we calibrate the stereo photogrammetric systems with the geometric constraint of the optical reference bar. The extrinsic parameters calibration process consists of linear parameters estimation based on quaternion and nonlinear refinement based on the maximum likelihood criterion. Firstly, we linear estimate the extrinsic parameters of the stereo photogrameetric systems based on quaternion. Then with the quaternion results as the initial values, we refine the extrinsic parameters through maximum likelihood criterion with the Levenberg-Marquardt Algorithm. In the calibration process, we can automatically control the light intensity and optimize the exposure time to get uniform intensity profile of the image points at different distance and obtain higher S/N ratio. The experiment result proves that the calibration method proposed is flexible, valid and obtains good results in the application

  1. Study on the System Requirements and Structures of Mailbox Declaration System for Reference Pyroprocessing Facility in the ROK

    International Nuclear Information System (INIS)

    Jeon, Jong Kyu

    2011-01-01

    The mailbox declaration system applied for the implementation of Safeguards at the Reference Pyroprocessing Facility (REPF) plays important role to support the declared information provided from Near-Real Time Accountancy (NRTA) and provides reference data to confirm the measurement results generated from the Unattended Monitoring System (UMS) for the purposes of verification and real-time monitoring of the movements and changes of nuclear materials (NM) at the processes in the REPF. In order to install and operate the mailbox declaration system at the REPF, this study focused on the operation, security, transmission of confidential information, procedure for transmission of mailbox declaration system as system requirements, and structure of mailbox declaration system to review the declared information through the mailbox by the national authority and to transmit the revised information to the IAEA

  2. LibraryH3lp: A New Flexible Chat Reference System

    Directory of Open Access Journals (Sweden)

    Pam Sessoms

    2008-09-01

    Full Text Available LibraryH3lp is an integrated IM and web chat system designed specifically for Virtual Reference services in libraries. The software was designed for, and is currently used by, a night-time chat reference collaboraton between several large academic libraries. LibraryH3lp is designed for the workflow of chat reference, supporting multiple simultaneous operators and routing to queues of operators in a particular service area. It also supports web page embeddable chat 'widgets', as well as simultaneous gateways to multiple IM protocols. This article discusses the motivation for the development of the software, and provides an overview of LibraryH3lp's features and technical architecture. Parts of LibraryH3lp are available as open source. The complete application is available as a low-cost hosted service, and will eventually be available to be licensed for local hosting.

  3. Performance Guaranteed Inertia Emulation forDiesel-Wind System Feed Microgrid via ModelReference Control

    Energy Technology Data Exchange (ETDEWEB)

    Melin, Alexander M. [ORNL; Zhang, Yichen [University of Tennessee, Knoxville (UTK), Department of Electrical Engineering and Computer Science; Djouadi, Seddik [University of Tennessee, Knoxville (UTK), Department of Electrical Engineering and Computer Science; Olama, Mohammed M. [ORNL

    2017-04-01

    In this paper, a model reference control based inertia emulation strategy is proposed. Desired inertia can be precisely emulated through this control strategy so that guaranteed performance is ensured. A typical frequency response model with parametrical inertia is set to be the reference model. A measurement at a specific location delivers the information of disturbance acting on the diesel-wind system to the referencemodel. The objective is for the speed of the diesel-wind system to track the reference model. Since active power variation is dominantly governed by mechanical dynamics and modes, only mechanical dynamics and states, i.e., a swing-engine-governor system plus a reduced-order wind turbine generator, are involved in the feedback control design. The controller is implemented in a three-phase diesel-wind system feed microgrid. The results show exact synthetic inertia is emulated, leading to guaranteed performance and safety bounds.

  4. Water Quality in Small Community Distribution Systems. A Reference Guide for Operators

    Science.gov (United States)

    The U.S. Environmental Protection Agency (EPA) has developed this reference guide to assist the operators and managers of small- and medium-sized public water systems. This compilation provides a comprehensive picture of the impact of the water distribution system network on dist...

  5. EUPOS - Satellite multifunctional system of reference stations in Central and Eastern Europe

    Science.gov (United States)

    Sledzinski, J.

    2003-04-01

    The European project EUPOS (European Position Determination System) of establishment of a system of multifunctional satellite reference stations in Central and Eastern Europe is described in the paper. Fifteen countries intend to participate in the project: Bulgaria, Croatia, Czech Republic, Estonia, Germany, Hungary, Latvia, Lithuania, Macedonia, Poland, Romania, Russia, Serbia, Slovak Republic and Slovenia. One common project will be prepared for all countries, however it will include the existing or developed infrastructure in particular countries. The experiences of establishing and operating of the German network SAPOS as well as experiences gained by other countries will be used. The European network of stations will be compatible with the system SAPOS and future European system Galileo. The network of reference stations will provide signal for both positioning of the geodetic control points and for land, air and marine navigation. Several levels of positioning accuracy will be delivered.

  6. Development of reference problems for neutron capture therapy treatment planning systems

    International Nuclear Information System (INIS)

    Albritton, J.R.; Kiger, W.S. III

    2006-01-01

    Currently, 5 different treatment planning systems (TPSs) are or have been used in clinical trials of Neutron Capture Therapy (NCT): MacNCTPlan, NCTPlan, BNCT Rtpe, SERA, and JCDS. This paper describes work performed to comprehensively test and compare 4 of these NCT treatment planning systems in order to facilitate the pooling of patient data from the different clinical sites for analysis of the clinical results as well as to provide an important quality assurance tool for existing and future TPSs. Two different phantoms were used to evaluate the planning systems: the modified Snyder head phantom and a large water-filled box, similar to that used in the International Dosimetry Exchange for NCT. The comparison of the resulting dose profile, isodose contours, and dose volume histograms to reference calculations performed with the Monte Carlo radiation transport code MCNP5 yielded many interesting differences. Each of the planning systems deviated from the reference calculations, with the newer systems (i.e., SERA and NCTPlan) most often yielding better agreement than their predecessors (i.e., BNCT Rtpe and MacNCTPlan). The combination of simple phantoms and sources with more complicated and realistic planning conditions has produced a well-rounded and useful suite of test problems for NCT treatment planning system analysis. (author)

  7. Application Research of Horn Array Multi-Beam Antenna in Reference Source System for Satellite Interference Location

    Science.gov (United States)

    Zhou, Ping; Lin, Hui; Zhang, Qi

    2018-01-01

    The reference source system is a key factor to ensure the successful location of the satellite interference source. Currently, the traditional system used a mechanical rotating antenna which leaded to the disadvantages of slow rotation and high failure-rate, which seriously restricted the system’s positioning-timeliness and became its obvious weaknesses. In this paper, a multi-beam antenna scheme based on the horn array was proposed as a reference source for the satellite interference location, which was used as an alternative to the traditional reference source antenna. The new scheme has designed a small circularly polarized horn antenna as an element and proposed a multi-beamforming algorithm based on planar array. Moreover, the simulation analysis of horn antenna pattern, multi-beam forming algorithm and simulated satellite link cross-ambiguity calculation have been carried out respectively. Finally, cross-ambiguity calculation of the traditional reference source system has also been tested. The comparison between the results of computer simulation and the actual test results shows that the scheme is scientific and feasible, obviously superior to the traditional reference source system.

  8. Fluorescence tracers as a reference for pesticide transport in wetland systems

    Science.gov (United States)

    Lange, Jens; Passeport, Elodie; Tournebize, Julien

    2010-05-01

    Two different fluorescent tracers, Uranine (UR) and Sulforhodamine (SRB), were injected as a pulse into surface flow wetlands. Tracer breakthrough curves were used to document hydraulic efficiencies, peak attenuation and retention capacities of completely different wetland systems. The tracers were used as a reference to mimic photolytic decay (UR) and sorption (SRB) of contaminants, since a real herbicide (Isoproturon, IPU) was injected in parallel to UR and SRB. Analysis costs limited IPU sampling frequency and single samples deviated from the tracer breakthrough curves. Still, a parallel behavior of IPU and SRB could be observed in totally different wetland systems, including underground passage through drainage lines. Similar recovery rates for IPU and SRB confirmed this observation. Hence, SRB was found to be an appropriate reference tracer to mimic the behavior of mobile pesticides (low KOC, without degradation) in wetland systems and the obtained wetland characteristics for SRB may serve as an indication for contaminant retention. Owing to the properties of IPU, the obtained results should be treated as worst case scenarios for highly mobile pesticides. A comparison of six different wetland types suggested that non-steady wetland systems with large variation in water level may temporally store relatively large amounts of tracers (contaminants), partly in areas that are not continuously saturated. This may lead to an efficient attenuation of peak concentrations. However, when large parts of these systems are flushed by natural storm events, tracers (contaminants) may be re-mobilized. In steady systems vegetation density and water depth were found to be the most important factors for tracer/contaminant retention. Illustrated by SRB, sorption on sediments and vegetation was a quick, almost instantaneous process which lead to considerable tracer losses even at high flow velocities and short contact times. Shallow systems with dense vegetation appeared to be the

  9. Four Reference Models for Transparency Requirements in Information Systems

    OpenAIRE

    Hosseini, Mahmoud; Shahri, Alimohammad; Phalp, Keith T.; Ali, Ra

    2017-01-01

    Transparency is a key emerging requirement in modern businesses and their information systems. Transparency refers to the information which flows amongst stakeholders for the purpose of informed decision-making and taking the right action. Transparency is generally associated with positive connotations such as trust and accountability. However, it has been shown that it could have adverse effects such as information overload and affecting decisions objectiveness. This calls for systematic app...

  10. 76 FR 16604 - Certain Preserved Mushrooms From the People's Republic of China: Final Results and Final...

    Science.gov (United States)

    2011-03-24

    ... DEPARTMENT OF COMMERCE International Trade Administration [A-570-851] Certain Preserved Mushrooms... (NSRs) of the antidumping duty order on certain preserved mushrooms from the People's Republic of China... Industry Co., Ltd. (Tongfa). See Certain Preserved Mushrooms from the People's Republic of China...

  11. Semiclassical neutral atom as a reference system in density functional theory.

    Science.gov (United States)

    Constantin, Lucian A; Fabiano, E; Laricchia, S; Della Sala, F

    2011-05-06

    We use the asymptotic expansions of the semiclassical neutral atom as a reference system in density functional theory to construct accurate generalized gradient approximations (GGAs) for the exchange-correlation and kinetic energies without any empiricism. These asymptotic functionals are among the most accurate GGAs for molecular systems, perform well for solid state, and overcome current GGA state of the art in frozen density embedding calculations. Our results also provide evidence for the conjointness conjecture between exchange and kinetic energies of atomic systems.

  12. Changing quantum reference frames

    OpenAIRE

    Palmer, Matthew C.; Girelli, Florian; Bartlett, Stephen D.

    2013-01-01

    We consider the process of changing reference frames in the case where the reference frames are quantum systems. We find that, as part of this process, decoherence is necessarily induced on any quantum system described relative to these frames. We explore this process with examples involving reference frames for phase and orientation. Quantifying the effect of changing quantum reference frames serves as a first step in developing a relativity principle for theories in which all objects includ...

  13. A STUDY ON DETERMINING THE REFERENCE SPREADING SEQUENCES FOR A DS/CDMACOMMUNICATION SYSTEM

    Directory of Open Access Journals (Sweden)

    Cebrail ÇİFTLİKLİ

    2002-02-01

    Full Text Available In a direct sequence/code division multiple access (DS/CDMA system, the role of the spreading sequences (codes is crucial since the multiple access interference (MAI is the main performance limitation. In this study, we propose an accurate criterion which enables the determination of the reference spreading codes which yield lower bit error rates (BER's in a given code set for a DS/CDMA system using despreading sequences weighted by stepping chip waveforms. The numerical results show that the spreading codes determined by the proposed criterion are the most suitable codes for using as references.

  14. User satisfaction with referrals at a collaborative virtual reference service Virtual reference services, Reference services, Referrals, User satisfaction

    Directory of Open Access Journals (Sweden)

    Nahyun Kwon

    2006-01-01

    Full Text Available Introduction. This study investigated unmonitored referrals in a nationwide, collaborative chat reference service. Specifically, it examined the extent to which questions are referred, the types of questions that are more likely to be referred than others, and the level of user satisfaction with the referrals in the collaborative chat reference service. Method. The data analysed for this study were 420 chat reference transaction transcripts along with corresponding online survey questionnaires submitted by the service users. Both sets of data were collected from an electronic archive of a southeastern state public library system that has participated in 24/7 Reference of the Metropolitan Cooperative Library System (MCLS. Results. Referrals in the collaborative chat reference service comprised approximately 30% of the total transactions. Circulation-related questions were the most often referred among all question types, possibly because of the inability of 'outside' librarians to access patron accounts. Most importantly, user satisfaction with referrals was found to be significantly lower than that of completed answers. Conclusion. The findings of this study addressed the importance of distinguishing two types of referrals: the expert research referrals conducive to collaborative virtual reference services; and the re-directional local referrals that increase unnecessary question traffic, thereby being detrimental to effective use of collaborative reference. Continuing efforts to conceptualize referrals in multiple dimensions are anticipated to fully grasp complex phenomena underlying referrals.

  15. A reference dosimetric system for dose interval of radiotherapy based on alanine/RPE

    International Nuclear Information System (INIS)

    Rodrigues Junior, Orlando; Galante, Ocimar L.; Campos, Leticia L.

    2001-01-01

    This work describes the development of a reference dosimetric system based on alanine/EPR for radiotherapy dose levels. Currently the IPEN is concluding a similar system for the dose range used for irradiation of products, 10-10 5 Gy. The objective of this work is to present the efforts towards to improve the measure accuracy for doses in the range between 1-10 Gy. This system could be used as reference by radiotherapy services, as much in the quality control of the equipment, as for routine accompaniment of more complex handling where the total doses can reach some grays. The system uses alanine as detector and electronic paramagnetic resonance - EPR as measure technique. To reach accuracy better than 5% mathematical studies on the best optimization of the EPR spectrometer parameters and methods for the handling of the EPR sign are discussed. (author)

  16. Design and implementation of predictive filtering system for current reference generation of active power filter

    Energy Technology Data Exchange (ETDEWEB)

    Kilic, Tomislav; Milun, Stanko; Petrovic, Goran [FESB University of Split, Faculty of Electrical Engineering, Machine Engineering and Naval Architecture, R. Boskovica bb, 21000, Split (Croatia)

    2007-02-15

    The shunt active power filters are used to attenuate the harmonic currents in power systems by injecting equal but opposite compensating currents. Successful control of the active filters requires an accurate current reference. In this paper the current reference determination based on predictive filtering structure is presented. Current reference was obtained by taking the difference of load current and its fundamental harmonic. For fundamental harmonic determination with no time delay a combination of digital predictive filter and low pass filter is used. The proposed method was implemented on a laboratory prototype of a three-phase active power filter. The algorithm for current reference determination was adapted and implemented on DSP controller. Simulation and experimental results show that the active power filter with implemented predictive filtering structure gives satisfactory performance in power system harmonic attenuation. (author)

  17. A reference model for model-based design of critical infrastructure protection systems

    Science.gov (United States)

    Shin, Young Don; Park, Cheol Young; Lee, Jae-Chon

    2015-05-01

    Today's war field environment is getting versatile as the activities of unconventional wars such as terrorist attacks and cyber-attacks have noticeably increased lately. The damage caused by such unconventional wars has also turned out to be serious particularly if targets are critical infrastructures that are constructed in support of banking and finance, transportation, power, information and communication, government, and so on. The critical infrastructures are usually interconnected to each other and thus are very vulnerable to attack. As such, to ensure the security of critical infrastructures is very important and thus the concept of critical infrastructure protection (CIP) has come. The program to realize the CIP at national level becomes the form of statute in each country. On the other hand, it is also needed to protect each individual critical infrastructure. The objective of this paper is to study on an effort to do so, which can be called the CIP system (CIPS). There could be a variety of ways to design CIPS's. Instead of considering the design of each individual CIPS, a reference model-based approach is taken in this paper. The reference model represents the design of all the CIPS's that have many design elements in common. In addition, the development of the reference model is also carried out using a variety of model diagrams. The modeling language used therein is the systems modeling language (SysML), which was developed and is managed by Object Management Group (OMG) and a de facto standard. Using SysML, the structure and operational concept of the reference model are designed to fulfil the goal of CIPS's, resulting in the block definition and activity diagrams. As a case study, the operational scenario of the nuclear power plant while being attacked by terrorists is studied using the reference model. The effectiveness of the results is also analyzed using multiple analysis models. It is thus expected that the approach taken here has some merits

  18. High-density fluid-perturbation theory based on an inverse 12th-power hard-sphere reference system

    International Nuclear Information System (INIS)

    Ross, M.

    1979-01-01

    A variational theory is developed that is accurate at normal liquid densities and densities up to 4 times that of the argon triple point. This theory uses the inverse 12th-power potential as a reference system. The properties of this reference system are expressed in terms of hard-sphere packing fractions by using a modified form of hard-space variational theory. As a result of this ''bootstrapping,'' a variational procedure may be followed that employs the inverse 12th-power system as a reference but uses the hard-sphere packing fraction as the scaling parameter with which to minimize the Helmholtz free energy

  19. Inaccuracies when mixing coordinate reference frameworks in a system of systems simulation

    CSIR Research Space (South Africa)

    Duvenhage, B

    2007-09-01

    Full Text Available commonly used are flat and spherical earth. Another well known ERM is the World Geodetic System from 1984 (WGS 84). For the purposes of this paper the authors however focus on the simpler flat and spherical earth models with example coordinate... words, the equatorial and pole to pole diameters of the earth, as modelled in this ERM, are equal. This paper will use the term ‘real world’ ERMs to refer to spherical, WGS 84 and better ERM approximations. A. The Earth-Centred, Earth...

  20. 76 FR 67146 - Certain Preserved Mushrooms From the People's Republic of China: Final Results of Antidumping...

    Science.gov (United States)

    2011-10-31

    ... DEPARTMENT OF COMMERCE International Trade Administration [A-570-851] Certain Preserved Mushrooms... results of the new shipper reviews (NSRs) of the antidumping duty order on certain preserved mushrooms.... (Hongda) in the Final Results of New Shipper Review of the Antidumping Duty Order on Preserved Mushrooms...

  1. 76 FR 4287 - Certain Preserved Mushrooms From the People's Republic of China; Extension of Time Limit for...

    Science.gov (United States)

    2011-01-25

    ... DEPARTMENT OF COMMERCE International Trade Administration [A-570-851] Certain Preserved Mushrooms... reviews (NSRs) of the antidumping duty order on certain preserved mushrooms from the People's Republic of China, covering the period of February 1, 2009, to January 31, 2010. See Certain Preserved Mushrooms...

  2. 75 FR 60076 - Certain Preserved Mushrooms from the People's Republic of China; Extension of Time Limit for...

    Science.gov (United States)

    2010-09-29

    ... DEPARTMENT OF COMMERCE International Trade Administration (A-570-851) Certain Preserved Mushrooms... reviews (NSRs) of the antidumping duty order on certain preserved mushrooms from the People's Republic of China, covering the period of February 1, 2009, to January 31, 2010. See Certain Preserved Mushrooms...

  3. 76 FR 16727 - Certain Preserved Mushrooms From the People's Republic of China; Extension of Time Limit for...

    Science.gov (United States)

    2011-03-25

    ... DEPARTMENT OF COMMERCE International Trade Administration [A-570-851] Certain Preserved Mushrooms... reviews (NSRs) of the antidumping duty order on certain preserved mushrooms from the People's Republic of China, covering the period of February 1, 2010, to July 31, 2010. See Certain Preserved Mushrooms From...

  4. 77 FR 20008 - Certain Frozen Fish Fillets From the Socialist Republic of Vietnam: Initiation of Antidumping...

    Science.gov (United States)

    2012-04-03

    ... DEPARTMENT OF COMMERCE International Trade Administration [A-552-801] Certain Frozen Fish Fillets... four new shipper reviews (``NSRs'') of the antidumping duty order on certain frozen fish fillets... Antidumping Duty Order: Certain Frozen Fish Fillets From the Socialist Republic of Vietnam, 68 FR 47909...

  5. Functional representation for the grand partition function of a multicomponent system of charged particles: Correlation functions of the reference system

    Directory of Open Access Journals (Sweden)

    O.V.Patsahan

    2006-01-01

    Full Text Available Based on the method of collective variables (CV with a reference system, the exact expression for the functional of the grand partition function of a m-component ionic model with charge and size asymmetry is found. Particular attention is paid to the n-th particle correlation functions of the reference system which is presented as a m-component system of "colour" hard spheres of the same diameter. A two-component model is considered in more detail. In this case the recurrence formulas for the correlation functions are found. A general case of a m-component inhomogeneous system of the "colour" hard spheres is also analysed.

  6. Moving to a Modernized Height Reference System in Canada: Rationale, Status and Plans

    Science.gov (United States)

    Veronneau, M.; Huang, J.

    2007-05-01

    A modern society depends on a common coordinate reference system through which geospatial information can be interrelated and exploited reliably. For height measurements this requires the ability to measure mean sea level elevations easily, accurately, and at the lowest possible cost. The current national reference system for elevations, the Canadian Geodetic Vertical Datum of 1928 (CGVD28), offers only partial geographic coverage of the Canadian territory and is affected by inaccuracies that are becoming more apparent as users move to space- based technologies such as GPS. Furthermore, the maintenance and expansion of the national vertical network using spirit-levelling, a costly, time consuming and labour intensive proposition, has only been minimally funded over the past decade. It is now generally accepted that the most sustainable alternative for the realization of a national vertical datum is a gravimetric geoid model. This approach defines the datum in relation to an ellipsoid, making it compatible with space-based technologies for positioning. While simplifying access to heights above mean sea level all across the Canadian territory, this approach imposes additional demands on the quality of the geoid model. These are being met by recent and upcoming space gravimetry missions that have and will be measuring the Earth`s gravity field with increasing and unprecedented accuracy. To maintain compatibility with the CGVD28 datum materialized at benchmarks, the current first-order levelling can be readjusted by constraining geoid heights at selected stations of the Canadian Base Network. The new reference would change CGVD28 heights of benchmarks by up to 1 m across Canada. However, local height differences between benchmarks would maintain a relative precision of a few cm or better. CGVD28 will co-exist with the new height reference as long as it will be required, but it will undoubtedly disappear as benchmarks are destroyed over time. The adoption of GNSS

  7. Phase modulated high density collinear holographic data storage system with phase-retrieval reference beam locking and orthogonal reference encoding.

    Science.gov (United States)

    Liu, Jinpeng; Horimai, Hideyoshi; Lin, Xiao; Huang, Yong; Tan, Xiaodi

    2018-02-19

    A novel phase modulation method for holographic data storage with phase-retrieval reference beam locking is proposed and incorporated into an amplitude-encoding collinear holographic storage system. Unlike the conventional phase retrieval method, the proposed method locks the data page and the corresponding phase-retrieval interference beam together at the same location with a sequential recording process, which eliminates piezoelectric elements, phase shift arrays and extra interference beams, making the system more compact and phase retrieval easier. To evaluate our proposed phase modulation method, we recorded and then recovered data pages with multilevel phase modulation using two spatial light modulators experimentally. For 4-level, 8-level, and 16-level phase modulation, we achieved the bit error rate (BER) of 0.3%, 1.5% and 6.6% respectively. To further improve data storage density, an orthogonal reference encoding multiplexing method at the same position of medium is also proposed and validated experimentally. We increased the code rate of pure 3/16 amplitude encoding method from 0.5 up to 1.0 and 1.5 using 4-level and 8-level phase modulation respectively.

  8. Normalization of NDVI from Different Sensor System using MODIS Products as Reference

    International Nuclear Information System (INIS)

    Wenxia, Gan; Liangpei, Zhang; Wei, Gong; Huanfeng, Shen

    2014-01-01

    Medium Resolution NDVI(Normalized Difference Vegetation Index) from different sensor systems such as Landsat, SPOT, ASTER, CBERS and HJ-1A/1B satellites provide detailed spatial information for studies of ecosystems, vegetation biophysics, and land cover. Limitation of sensor designs, cloud contamination, and sensor failure highlighted the need to normalize and integrate NDVI from multiple sensor system in order to create a consistent, long-term NDVI data set. In this paper, we used a reference-based method for NDVI normalization. And present an application of this approach which covert Landsat ETM+ NDVI calculated by digital number (NDVI DN ) to NDVI calculated by surface reflectance (NDVI SR ) using MODIS products as reference, and different cluster was treated differently. Result shows that this approach can produce NDVI with highly agreement to NDVI calculated by surface reflectance from physical approaches based on 6S (Second Simulation of the satellite Signal in the Solar Spectrum). Although some variability exists, the cluster specified reference based approach shows considerable potential for NDVI normalization. Therefore, NDVI products in MODIS era from different sources can be combined for time-series analysis, biophysical parameter retrievals, and other downstream analysis

  9. The Absolute Stability Analysis in Fuzzy Control Systems with Parametric Uncertainties and Reference Inputs

    Science.gov (United States)

    Wu, Bing-Fei; Ma, Li-Shan; Perng, Jau-Woei

    This study analyzes the absolute stability in P and PD type fuzzy logic control systems with both certain and uncertain linear plants. Stability analysis includes the reference input, actuator gain and interval plant parameters. For certain linear plants, the stability (i.e. the stable equilibriums of error) in P and PD types is analyzed with the Popov or linearization methods under various reference inputs and actuator gains. The steady state errors of fuzzy control systems are also addressed in the parameter plane. The parametric robust Popov criterion for parametric absolute stability based on Lur'e systems is also applied to the stability analysis of P type fuzzy control systems with uncertain plants. The PD type fuzzy logic controller in our approach is a single-input fuzzy logic controller and is transformed into the P type for analysis. In our work, the absolute stability analysis of fuzzy control systems is given with respect to a non-zero reference input and an uncertain linear plant with the parametric robust Popov criterion unlike previous works. Moreover, a fuzzy current controlled RC circuit is designed with PSPICE models. Both numerical and PSPICE simulations are provided to verify the analytical results. Furthermore, the oscillation mechanism in fuzzy control systems is specified with various equilibrium points of view in the simulation example. Finally, the comparisons are also given to show the effectiveness of the analysis method.

  10. 76 FR 52315 - Fresh Garlic From the People's Republic of China: Final Rescission of New Shipper Reviews of...

    Science.gov (United States)

    2011-08-22

    ... DEPARTMENT OF COMMERCE International Trade Administration [A-570-831] Fresh Garlic From the People's Republic of China: Final Rescission of New Shipper Reviews of Jining Yifa Garlic Produce Co., Ltd... (Department) published a preliminary intent to rescind the new shipper reviews (NSRs) of fresh garlic from the...

  11. 75 FR 5764 - Honey from the People's Republic of China: Initiation of New Shipper Antidumping Duty Reviews

    Science.gov (United States)

    2010-02-04

    ... DEPARTMENT OF COMMERCE International Trade Administration [A-570-863] Honey from the People's... (``NSRs'') of the antidumping duty order on honey from the People's Republic of China (``PRC''), received... from the People's Republic of China, 66 FR 63670 (December 10, 2001) (``Order''). On December 10, 2009...

  12. Normalization references for USEtoxTM-based toxic impact categories: North American and European economic systems

    DEFF Research Database (Denmark)

    Laurent, Alexis; Lautier, Anne; Rosenbaum, Ralph K.

    2011-01-01

    economic regions, North America and Europe, to calculate normalization references for the three currently-modelled USEtoxTM-based impact categories, i.e. freshwater ecotoxicity, human toxicity, divided into cancer effects and non-cancer effects. Base years for the references are 2004 for Europe and 2006...... coverage of organics in both the inventory and the CF databases. With respect to the intended global character of the USEtoxTM model, different approaches to determine normalization references of other economic systems (e.g. Asia or world) are discussed in relation to these findings. Overall, we thus...... recommend the use of the provided set of normalization references for USEtoxTM, but we also advocate 1) to perform an update as soon as a more comprehensive inventory can be obtained and as soon as characterization factors for metals are revised; 2) to consider extension to other economic systems in order...

  13. References for HNF-SD-WM-TRD-007, ''System specification for the double-shell tank system: HNF-PROs, CFRs, DOE Orders, WACs''

    International Nuclear Information System (INIS)

    Shaw, C.P.

    1998-01-01

    HNF-SD-WM-TRD-O07, System Specification for the Double-Shell Tank System, (hereafter referred to as DST Specification), defines the requirements of the double-shell tank system at the Hanford Site for Phase 1 privatization. Many of the sections in this document reference other documents for design guidance and requirements. Referenced documents include Project Hanford Management Contract (PHMC) procedures (HNF-PROS), Codes of Federal Regulation (CFRs), DOE Orders, and Washington Administrative Codes (WACs). This document provides rationale for the selection and inclusion of HNF-PROS, CFRs, DOE Orders and WACs

  14. Reference Concepts for a Space-Based Hydrogen-Oxygen Combustion, Turboalternator, Burst Power System

    National Research Council Canada - National Science Library

    Edenburn, Michael

    1990-01-01

    This report describes reference concepts for a hydrogen-oxygen combustion, turboalternator power system that supplies power during battle engagement to a space-based, ballistic missile defense platform...

  15. New reference object for metrological performance testing of industrial CT systems

    DEFF Research Database (Denmark)

    Müller, Pavel; Hiller, Jochen; Cantatore, Angela

    2012-01-01

    This paper presents a new reference object, so called “CT ball plate”, used for metrological performance testing of industrial CT systems, and discusses both the calibration procedure using a tactile coordinate measuring machine and the first results carried out using an industrial CT scanner....... This artefact can be used to determine several characteristics of the CT system like, probing errors of spheres, length measuring errors between sphere centers, measurement errors in the whole CT volume and effects in connection with image artefacts....

  16. Reference-tracking feedforward control design for linear dynamical systems through signal decomposition

    NARCIS (Netherlands)

    Kasemsinsup, Y.; Romagnoli, R.; Heertjes, M.F.; Weiland, S.; Butler, H.

    2017-01-01

    In this work, we study a novel approach towards the reference-tracking feedforward control design for linear dynamical systems. By utilizing the superposition property and exploiting signal decomposition together with a quadratic optimization process, we obtain a feedforward design procedure for

  17. Neural network-based model reference adaptive control system.

    Science.gov (United States)

    Patino, H D; Liu, D

    2000-01-01

    In this paper, an approach to model reference adaptive control based on neural networks is proposed and analyzed for a class of first-order continuous-time nonlinear dynamical systems. The controller structure can employ either a radial basis function network or a feedforward neural network to compensate adaptively the nonlinearities in the plant. A stable controller-parameter adjustment mechanism, which is determined using the Lyapunov theory, is constructed using a sigma-modification-type updating law. The evaluation of control error in terms of the neural network learning error is performed. That is, the control error converges asymptotically to a neighborhood of zero, whose size is evaluated and depends on the approximation error of the neural network. In the design and analysis of neural network-based control systems, it is important to take into account the neural network learning error and its influence on the control error of the plant. Simulation results showing the feasibility and performance of the proposed approach are given.

  18. Scalar material reference systems and loop quantum gravity

    International Nuclear Information System (INIS)

    Giesel, K; Thiemann, T

    2015-01-01

    In the past, the possibility to employ (scalar) material reference systems in order to describe classical and quantum gravity directly in terms of gauge invariant (Dirac) observables has been emphasized frequently. This idea has been picked up more recently in loop quantum gravity with the aim to perform a reduced phase space quantization of the theory, thus possibly avoiding problems with the (Dirac) operator constraint quantization method for a constrained system. In this work, we review the models that have been studied on the classical and/or the quantum level and parametrize the space of theories considered so far. We then describe the quantum theory of a model that, to the best of our knowledge, has only been considered classically so far. This model could arguably be called the optimal one in this class of models considered as it displays the simplest possible true Hamiltonian, while at the same time reducing all constraints of general relativity. (paper)

  19. 76 FR 24857 - Fresh Garlic From the People's Republic of China: Preliminary Intent To Rescind New Shipper Reviews

    Science.gov (United States)

    2011-05-03

    ... DEPARTMENT OF COMMERCE International Trade Administration [A-570-831] Fresh Garlic From the People... conducting three new shipper reviews (NSRs) under the antidumping duty order on fresh garlic from the People... Yifa Garlic Produce Co., Ltd. (Jining Yifa) for the period of review (POR) November 1, 2009, through...

  20. Elderly Bias, New Social Risks, and Social Spending

    DEFF Research Database (Denmark)

    Tepe, Markus; Vanhuysse, Pieter

    2010-01-01

    of the large-scale arrival of such risks 'on the ground' does play a key role. Countries that entered the postindustrial society comparatively late record lower NSRS values, as they spend less on programs such as education and family allowances. Institutional differences as captured by welfare regime type...

  1. Pediatric reference value distributions and covariate-stratified reference intervals for 29 endocrine and special chemistry biomarkers on the Beckman Coulter Immunoassay Systems: a CALIPER study of healthy community children.

    Science.gov (United States)

    Karbasy, Kimiya; Lin, Danny C C; Stoianov, Alexandra; Chan, Man Khun; Bevilacqua, Victoria; Chen, Yunqi; Adeli, Khosrow

    2016-04-01

    The CALIPER program is a national research initiative aimed at closing the gaps in pediatric reference intervals. CALIPER previously reported reference intervals for endocrine and special chemistry markers on Abbott immunoassays. We now report new pediatric reference intervals for immunoassays on the Beckman Coulter Immunoassay Systems and assess platform-specific differences in reference values. A total of 711 healthy children and adolescents from birth to reference intervals calculated in accordance with Clinical and Laboratory Standards Institute (CLSI) EP28-A3c guidelines. Complex profiles were observed for all 29 analytes, necessitating unique age and/or sex-specific partitions. Overall, changes in analyte concentrations observed over the course of development were similar to trends previously reported, and are consistent with biochemical and physiological changes that occur during childhood. Marked differences were observed for some assays including progesterone, luteinizing hormone and follicle-stimulating hormone where reference intervals were higher than those reported on Abbott immunoassays and parathyroid hormone where intervals were lower. This study highlights the importance of determining reference intervals specific for each analytical platform. The CALIPER Pediatric Reference Interval database will enable accurate diagnosis and laboratory assessment of children monitored by Beckman Coulter Immunoassay Systems in health care institutions worldwide. These reference intervals must however be validated by individual labs for the local pediatric population as recommended by CLSI.

  2. Modification of reference temperature program in reactor regulating system

    Energy Technology Data Exchange (ETDEWEB)

    Yu, Sung Sik; Lee, Byung Jin; Kim, Se Chang; Cheong, Jong Sik [Korea Power Engineering Company, Inc., Seoul (Korea, Republic of); Kim, Ji In; Doo, Jin Yong [Korea Electric Power Cooperation, Yonggwang (Korea, Republic of)

    1999-12-31

    In Yonggwang nuclear units 3 and 4 currently under commercial operation, the cold temperature was very close to the technical specification limit of 298 deg C during initial startup testing, which was caused by the higher-than-expected reactor coolant system flow. Accordingly, the reference temperature (Tref) program needed to be revised to allow more flexibility for plant operations. In this study, the method of a specific test performed at Yonggwang nuclear unit 4 to revise the Tref program was described and the test results were discussed. In addition, the modified Tref program was evaluated on its potential impacts on system performance and safety. The methods of changing the Tref program and the associated pressurizer level setpoint program were also explained. Finally, for Ulchin nuclear unit 3 and 4 currently under initial startup testing, the effects of reactor coolant system flow rate on the coolant temperature were evaluated from the thermal hydraulic standpoint and an optimum Tref program was recommended. 6 refs., 4 figs., 2 tabs. (Author)

  3. Modification of reference temperature program in reactor regulating system

    Energy Technology Data Exchange (ETDEWEB)

    Yu, Sung Sik; Lee, Byung Jin; Kim, Se Chang; Cheong, Jong Sik [Korea Power Engineering Company, Inc., Seoul (Korea, Republic of); Kim, Ji In; Doo, Jin Yong [Korea Electric Power Cooperation, Yonggwang (Korea, Republic of)

    1998-12-31

    In Yonggwang nuclear units 3 and 4 currently under commercial operation, the cold temperature was very close to the technical specification limit of 298 deg C during initial startup testing, which was caused by the higher-than-expected reactor coolant system flow. Accordingly, the reference temperature (Tref) program needed to be revised to allow more flexibility for plant operations. In this study, the method of a specific test performed at Yonggwang nuclear unit 4 to revise the Tref program was described and the test results were discussed. In addition, the modified Tref program was evaluated on its potential impacts on system performance and safety. The methods of changing the Tref program and the associated pressurizer level setpoint program were also explained. Finally, for Ulchin nuclear unit 3 and 4 currently under initial startup testing, the effects of reactor coolant system flow rate on the coolant temperature were evaluated from the thermal hydraulic standpoint and an optimum Tref program was recommended. 6 refs., 4 figs., 2 tabs. (Author)

  4. Handbook of reference electrodes

    CERN Document Server

    Inzelt, György; Scholz, Fritz

    2013-01-01

    Reference Electrodes are a crucial part of any electrochemical system, yet an up-to-date and comprehensive handbook is long overdue. Here, an experienced team of electrochemists provides an in-depth source of information and data for the proper choice and construction of reference electrodes. This includes all kinds of applications such as aqueous and non-aqueous solutions, ionic liquids, glass melts, solid electrolyte systems, and membrane electrodes. Advanced technologies such as miniaturized, conducting-polymer-based, screen-printed or disposable reference electrodes are also covered. Essen

  5. Towards a reference ontology of complex economic exchanges for Accounting Information Systems

    NARCIS (Netherlands)

    Blums, Ivar; Weigand, Hans; Matthes, Flores; Mendling, Jan; Rinderle-Ma, Stefanie

    Although the field of Accounting Information Systems (AIS) has a long tradition, there is still a lack of a widely adopted conceptualization. The Unified Foundational Ontology (UFO) and its Services sub- ontology (UFO-S) are regarded as grounding the engineering of a reference ontology for AIS. The

  6. An analytic-numerical method for the construction of the reference law of operation for a class of mechanical controlled systems

    Science.gov (United States)

    Mizhidon, A. D.; Mizhidon, K. A.

    2017-04-01

    An analytic-numerical method for the construction of a reference law of operation for a class of dynamic systems describing vibrations in controlled mechanical systems is proposed. By the reference law of operation of a system, we mean a law of the system motion that satisfies all the requirements for the quality and design features of the system under permanent external disturbances. As disturbances, we consider polyharmonic functions with known amplitudes and frequencies of the harmonics but unknown initial phases. For constructing the reference law of motion, an auxiliary optimal control problem is solved in which the cost function depends on a weighting coefficient. The choice of the weighting coefficient ensures the design of the reference law. Theoretical foundations of the proposed method are given.

  7. Global Reference Tables for Production Systems

    Data.gov (United States)

    Social Security Administration — This database is a collection of reference tables that store common information used throughout SSA. These tables standardized code structures and code usage of SSA...

  8. Terminological reference of a knowledge-based system: the data dictionary.

    Science.gov (United States)

    Stausberg, J; Wormek, A; Kraut, U

    1995-01-01

    The development of open and integrated knowledge bases makes new demands on the definition of the used terminology. The definition should be realized in a data dictionary separated from the knowledge base. Within the works done at a reference model of medical knowledge, a data dictionary has been developed and used in different applications: a term definition shell, a documentation tool and a knowledge base. The data dictionary includes that part of terminology, which is largely independent of a certain knowledge model. For that reason, the data dictionary can be used as a basis for integrating knowledge bases into information systems, for knowledge sharing and reuse and for modular development of knowledge-based systems.

  9. Implementation of a system for external audits beam radiation therapy in terms of reference no

    International Nuclear Information System (INIS)

    Alonso Samper, Jose Luis; Dominguez, Lourdes; Alert Silva, Jose; Alfonso Laguardia, Rodolfo; Larrinaga Cortina, Eduardo; Garcia Yip, Fernando; Rodriguez Machado, Jorge; Morales Lopez, Jorge Luis; Silvestre Patallo, Ileana

    2009-01-01

    This paper presents our experience in implementing a external audit system for radiotherapy beam in no reference conditions with the use of CIRS and a summary of the measurements with him made.This paper presents our experience in implementing a external audit system for radiotherapy beam in no reference conditions with the use of CIRS and a summary of the measurements with him made. Centers were audited with external beam high-energy Co-60, 6 MV and 15 MV and were considered 4 treatment planning systems (TPS): AMEPLAN, Theraplan Plus, Precise Plan and MIRS to calculate doses prescribed in each test case. All measurements were acquired by the audit team using the anthropomorphic phantom CIRS, Semiflex chamber PTW 31010 and PTW electrometer STATES. The implementation and development of the external audits of beams radiotherapy in terms of 'no reference' has brought an improvement in both clinical aspects of treatment and the radiation safety and the quality control, has given us greater confidence and for this reason we believe has become essential. (Author)

  10. From the LHC Reference Database to the Powering Interlock System

    CERN Document Server

    Dehavay, C; Schmidt, R; Veyrunes, E; Zerlauth, M

    2003-01-01

    The protection of the magnet powering system for the Large Hadron Collider (LHC) currently being built at CERN is a major challenge due to the unprecedented complexity of the accelerator. The Powering Interlock System of the LHC will have to manage more than 1600 DC circuits for magnet powering, different in their structure, complexity and importance to the accelerator. For the coherent description of such complex system, a Reference Database as unique source of the parameters of the electrical circuits has been developed. The information, introduced via a generic circuit description language, is first used for installing the accelerator and making all electrical connections. The data is then used for tests and commissioning. During operation, the Powering Interlock System manages all critical functions. It consists of 36 PLC based controllers dis tributed around the machine and requires a flexible and transparent way of configuration, since each controller manages different numbers and types of electrical ci...

  11. Enhanced electricity system analysis for decision making - A reference book

    International Nuclear Information System (INIS)

    2000-01-01

    The objective of electricity system analysis in support of decision making is to provide comparative assessment results upon which relevant policy choices between alternative technology options and supply strategies can be based. This reference book offers analysts, planners and decision makers documented information on enhanced approaches to electricity system analysis, that can assist in achieving this objective. The book describes the main elements of comprehensive electricity system analysis and outlines an advanced integrated analysis and decision making framework for the electric power sector. Emphasis is placed on mechanisms for building consensus between interested and affected parties, and on aspects of planning that go beyond the traditional economic optimisation approach. The scope and contents of the book cover the topics to be addressed in decision making for the power sector and the process of integrating economic, social, health and environmental aspects in the comparative assessment of alternative options and strategies. The book describes and discusses overall frameworks, processes and state of the art methods and techniques available to analysts and planners for carrying out comparative assessment studies, in order to provide sound information to decision makers. This reference book is published as part of a series of technical reports and documents prepared in the framework of the inter-agency joint project (DECADES) on databases and methodologies for comparative assessment of different energy sources for electricity generation. The overall objective of the DECADES project is to enhance capabilities for incorporating economic, social, health and environmental issues in the comparative assessment of electricity generation options and strategies in the process of decision making for the power sector. The project, established in 1992, is carried out jointly by the European Commission (EC), the Economic and Social Commission for Asia and the Pacific

  12. Disturbance rejection performance analyses of closed loop control systems by reference to disturbance ratio.

    Science.gov (United States)

    Alagoz, Baris Baykant; Deniz, Furkan Nur; Keles, Cemal; Tan, Nusret

    2015-03-01

    This study investigates disturbance rejection capacity of closed loop control systems by means of reference to disturbance ratio (RDR). The RDR analysis calculates the ratio of reference signal energy to disturbance signal energy at the system output and provides a quantitative evaluation of disturbance rejection performance of control systems on the bases of communication channel limitations. Essentially, RDR provides a straightforward analytical method for the comparison and improvement of implicit disturbance rejection capacity of closed loop control systems. Theoretical analyses demonstrate us that RDR of the negative feedback closed loop control systems are determined by energy spectral density of controller transfer function. In this manner, authors derived design criteria for specifications of disturbance rejection performances of PID and fractional order PID (FOPID) controller structures. RDR spectra are calculated for investigation of frequency dependence of disturbance rejection capacity and spectral RDR analyses are carried out for PID and FOPID controllers. For the validation of theoretical results, simulation examples are presented. Copyright © 2014 ISA. Published by Elsevier Ltd. All rights reserved.

  13. Lodgepole pine site index in relation to synoptic measures of climate, soil moisture and soil nutrients.

    Science.gov (United States)

    G. Geoff Wang; Shongming Huang; Robert A. Monserud; Ryan J. Klos

    2004-01-01

    Lodgepole pine site index was examined in relation to synoptic measures of topography, soil moisture, and soil nutrients in Alberta. Data came from 214 lodgepole pine-dominated stands sampled as a part of the provincial permanent sample plot program. Spatial location (elevation, latitude, and longitude) and natural subregions (NSRs) were topographic variables that...

  14. The Uhlenbeck-Ford model: Exact virial coefficients and application as a reference system in fluid-phase free-energy calculations

    Science.gov (United States)

    Paula Leite, Rodolfo; Freitas, Rodrigo; Azevedo, Rodolfo; de Koning, Maurice

    2016-11-01

    The Uhlenbeck-Ford (UF) model was originally proposed for the theoretical study of imperfect gases, given that all its virial coefficients can be evaluated exactly, in principle. Here, in addition to computing the previously unknown coefficients B11 through B13, we assess its applicability as a reference system in fluid-phase free-energy calculations using molecular simulation techniques. Our results demonstrate that, although the UF model itself is too soft, appropriately scaled Uhlenbeck-Ford (sUF) models provide robust reference systems that allow accurate fluid-phase free-energy calculations without the need for an intermediate reference model. Indeed, in addition to the accuracy with which their free energies are known and their convenient scaling properties, the fluid is the only thermodynamically stable phase for a wide range of sUF models. This set of favorable properties may potentially put the sUF fluid-phase reference systems on par with the standard role that harmonic and Einstein solids play as reference systems for solid-phase free-energy calculations.

  15. Calibration of a multi-beam Laser System by using a TLS-generated Reference

    Directory of Open Access Journals (Sweden)

    M. Gordon

    2013-10-01

    Full Text Available Rotating multi-beam LIDARs mounted on moving platforms have become very successful for many applications such as autonomous navigation, obstacle avoidance or mobile mapping. To obtain accurate point coordinates, a precise calibration of such a LIDAR system is required. For the determination of the corresponding parameters we propose a calibration scheme which exploits the information of 3D reference point clouds captured by a terrestrial laser scanning (TLS device. It is assumed that the accuracy of this point clouds is considerably higher than that from the multi-beam LIDAR and that the data represent faces of man-made objects at different distances. After extracting planes in the reference data sets, the point-plane-incidences of the measured points and the reference planes are used to formulate the implicit constraints. We inspect the Velodyne HDL-64E S2 system as the best-known representative for this kind of sensor system. The usability and feasibility of the calibration procedure is demonstrated with real data sets representing building faces (walls, roof planes and ground. Beside the improvement of the point accuracy by considering the calibration results, we test the significance of the parameters related to the sensor model and consider the uncertainty of measurements w.r.t. the measured distances. The Velodyne returns two kinds of measurements – distances and encoder angles. To account for this, we perform a variance component estimation to obtain realistic standard deviations for the observations.

  16. Moving Reference to the Web.

    Science.gov (United States)

    McGlamery, Susan; Coffman, Steve

    2000-01-01

    Explores the possibility of using Web contact center software to offer reference assistance to remote users. Discusses a project by the Metropolitan Cooperative Library System/Santiago Library System consortium to test contact center software and to develop a virtual reference network. (Author/LRW)

  17. Global Area Reference System (GARS), 30-minute Blocks for Louisiana, WGS84, NGA (2007) [gars_la_30min_nga_2007

    Data.gov (United States)

    Louisiana Geographic Information Center — Global Area Reference System (GARS) is developed by the National Geospatial-Intelligence Agency (NGA) as an area reference system. GARS is based on lines of...

  18. On-board landmark navigation and attitude reference parallel processor system

    Science.gov (United States)

    Gilbert, L. E.; Mahajan, D. T.

    1978-01-01

    An approach to autonomous navigation and attitude reference for earth observing spacecraft is described along with the landmark identification technique based on a sequential similarity detection algorithm (SSDA). Laboratory experiments undertaken to determine if better than one pixel accuracy in registration can be achieved consistent with onboard processor timing and capacity constraints are included. The SSDA is implemented using a multi-microprocessor system including synchronization logic and chip library. The data is processed in parallel stages, effectively reducing the time to match the small known image within a larger image as seen by the onboard image system. Shared memory is incorporated in the system to help communicate intermediate results among microprocessors. The functions include finding mean values and summation of absolute differences over the image search area. The hardware is a low power, compact unit suitable to onboard application with the flexibility to provide for different parameters depending upon the environment.

  19. Fast breeder reactor reference system classification for the ENEA data bank

    International Nuclear Information System (INIS)

    Righini, R.

    1988-01-01

    This report contains the Reference System Classification (RSC) of fast breeder reactors: it provides a functional system breakdown of the reactor. For each system the following important characteristics are reported: the main function, the mode of operation, its location in the reactor, the main interface system, its main components and the component working environment (fluid and/or atmosphere type). The RSC represent a basic step in organizing the ENEA data bank for the registration and processing of reliability data on typical fast reactor components; it provides a functional component breakdown and represent a plant-unique identification in the process of omogenization of event-data coming from different reactors. In this report it was tried to take into account different generations of nuclear power plants, different plant layouts and solutions: in particular loop and pool reactors are separately treated

  20. Adaptive Control with Reference Model Modification

    Science.gov (United States)

    Stepanyan, Vahram; Krishnakumar, Kalmanje

    2012-01-01

    This paper presents a modification of the conventional model reference adaptive control (MRAC) architecture in order to improve transient performance of the input and output signals of uncertain systems. A simple modification of the reference model is proposed by feeding back the tracking error signal. It is shown that the proposed approach guarantees tracking of the given reference command and the reference control signal (one that would be designed if the system were known) not only asymptotically but also in transient. Moreover, it prevents generation of high frequency oscillations, which are unavoidable in conventional MRAC systems for large adaptation rates. The provided design guideline makes it possible to track a reference commands of any magnitude from any initial position without re-tuning. The benefits of the method are demonstrated with a simulation example

  1. An update to the analysis of the Canadian Spatial Reference System

    Science.gov (United States)

    Ferland, R.; Piraszewski, M.; Craymer, M.

    2015-12-01

    The primary objective of the Canadian Spatial Reference System (CSRS) is to provide users access to a consistent geo-referencing infrastructure over the Canadian landmass. Global Navigation Satellite System (GNSS) positioning accuracy requirements ranges from meter level to mm level (e.g.: crustal deformation). The highest level of the Canadian infrastructure consist of a network of continually operating GPS and GNSS receivers, referred to as active control stations. The network includes all Canadian public active control stations, some bordering US CORS and Alaska stations, Greenland active control stations, as well as a selection of IGS reference frame stations. The Bernese analysis software is used for the daily processing and the combination into weekly solutions which form the basis for this analysis. IGS weekly final orbit, Earth Rotation parameters (ERP's) and coordinates products are used in the processing. For the more demanding users, the time dependant changes of station coordinates is often more important.All station coordinate estimates and related covariance information is used in this analysis. For each input solution, variance factor, translation, rotation and scale (and if needed their rates) or subsets of these are estimated. In the combination of these weekly solutions, station positions and velocities are estimated. Since the time series from the stations in these networks often experience changes in behavior, new (or reuse of) parameters are generally used in these situations. As is often the case with real data, unrealistic coordinates may occur. Automatic detection and removal of outliers is used in these cases. For the transformation, position and velocity parameters loose apriori estimates and uncertainties are provided. Alignment using the usual Helmert transformation to the latest IGb08 realization of ITRF is also performed during the adjustment.

  2. Rate of alignment and communication using quantum systems in the absence of a shared frame of reference

    Science.gov (United States)

    Skotiniotis, Michael

    Quantum information theory is concerned with the storage, transmission, and manipulation of information that is represented in the degrees of freedom of quantum systems. These degrees of freedom are described relative to an external frame of reference. The lack of a requisite frame of reference imposes restrictions on the types of states quantum systems can be prepared in and the type of operations that can be performed on quantum systems. This thesis is concerned with the communication between two parties that lack a shared frame of reference. Specifically, I introduce a protocol whereby the parties can align their respective frames of reference, and a protocol for communicating quantum information in a reference frame independent manner. Using the accessible information to quantify the success of a reference frame alignment protocol I propose a new measure—the alignment rate—for quantifying the ability of a quantum state to stand in place of a classical frame of reference. I show that for the case where Alice and Bob lack a shared frame of reference associated with the groups G = U(1) and G = ZM (the finite cyclic group of M elements), the alignment rate is equal to the regularized, linearized G-asymmetry. The latter is a unique measure of the frameness of a quantum state and my result provides an operational interpretation of the G-asymmetry that was thus far lacking. In addition, I show that the alignment rate for finite cyclic groups of more than three elements is super-additive under the tensor product of two distinct pure quantum states. The latter is, to my knowledge, the first instance of a regularized quantity that exhibits super-additivity. In addition, I propose a reference-frame-independent protocol for communicating quantum information in the absence of a shared frame of reference associated with a general finite group G. The protocol transmits m logical qudits using r + m physical qudits prepared in a specific state that is reference

  3. Specifications for trueness and precision of a reference measurement system for serum/plasma 25-hydroxyvitamin D analysis.

    Science.gov (United States)

    Stöckl, Dietmar; Sluss, Patrick M; Thienpont, Linda M

    2009-10-01

    The divergence in analytical quality of serum/plasma 25-hydroxy-vitamin D analysis calls for defining specifications for a reference measurement system. Fundamentally, in a reference measurement system, there should be a relationship between the analytical specifications for higher- (reference) and lower-order (routine) measurements. Therefore, when setting specifications, we started with limits for routine imprecision (CV(rou)) and bias (B(rou)) using 4 models: (1) the misclassifications in diagnosis, (2) biological variation data (reference interval (RI) and monitoring), (3) expert recommendations, and (4) state-of-the-art performance. Then, we used the derived goals to tailor those for reference measurements and certified reference materials (CRMs) for calibration by setting the limits for CV(ref) at 0.5 CV(rou), B(ref) at 0.33 B(rou)(,) max. uncertainty (U(max)) at 0.33 B(ref). The established specifications ranged between CV(rou)model 3) and CV(rou)model 2, monitoring). Model 2 (monitoring) gave the most stringent goals, model 3, the most liberal ones. Accounting for state-of-the-art performance and certification capabilities, we used model 2 (RI) to recommend achievable goals: for routine testing, CV(rou)measurements, CV(ref)

  4. Investigation on Reference Frames and Time Systems in Multi-GNSS

    Directory of Open Access Journals (Sweden)

    Luca Nicolini

    2018-01-01

    Full Text Available Receivers able to track satellites belonging to different GNSSs (Global Navigation Satellite Systems are available on the market. To compute coordinates and velocities it is necessary to identify all the elements that contribute to interoperability of the different GNSSs. For example the timescales kept by different GNSSs have to be aligned. Receiver-specific biases, or firmware-dependent biases, need to be calibrated. The reference frame used in the representation of the orbits must be unique. In this paper we address the interoperability issues from the standpoint of a Single Point Positioning (SPP user, i.e., using pseudoranges and broadcast ephemeris. The biases between GNSSs timescales and receiver-dependent biases are analyzed for a set of 31 MGEX (Multi-GNSS Experiment stations over a time span of more than three years. Time series of biases between timescales of GPS (Global Positioning System, GLONASS (Global Navigation Satellite System, Galileo, BeiDou, QZSS (Quasi-Zenith Satellite System, SBAS (Satellite Based Augmentation System and NAVIC (Navigation with Indian Constellation are investigated, in addition to the identification of events like discontinuity of receiver-dependent biases due to firmware updating. The GPS broadcast reference frame is shown to be aligned to the one (IGS14 realized by the precise ephemeris of CODE (Center for Orbit Determination in Europe to within 0.1 m and 2 milliarcsec, with values dependent on whether IIR-A, IIR-B/M or IIF satellite blocks are considered. Larger offsets are observed for GLONASS, up to 1 m for GLONASS K satellites. For Galileo the alignment of the broadcast orbit to IGS14/CODE is again at the 0.1 m and several milliarcsec level, with the FOC (Full Operational Capability satellites slightly better than IOV (In Orbit Validation. For BeiDou an alignment of the broadcast frame to IGS14/CODE comparable to GLONASS is observed, regardless of whether IGSO (Inclined Geosynchronous Orbit or MEO

  5. A Proposal of New Reference System for the Standard Axial, Sagittal, Coronal Planes of Brain Based on the Serially-Sectioned Images

    Science.gov (United States)

    Park, Jin Seo; Park, Hyo Seok; Shin, Dong Sun; Har, Dong-Hwan; Cho, Zang-Hee; Kim, Young-Bo; Han, Jae-Yong; Chi, Je-Geun

    2010-01-01

    Sectional anatomy of human brain is useful to examine the diseased brain as well as normal brain. However, intracerebral reference points for the axial, sagittal, and coronal planes of brain have not been standardized in anatomical sections or radiological images. We made 2,343 serially-sectioned images of a cadaver head with 0.1 mm intervals, 0.1 mm pixel size, and 48 bit color and obtained axial, sagittal, and coronal images based on the proposed reference system. This reference system consists of one principal reference point and two ancillary reference points. The two ancillary reference points are the anterior commissure and the posterior commissure. And the principal reference point is the midpoint of two ancillary reference points. It resides in the center of whole brain. From the principal reference point, Cartesian coordinate of x, y, z could be made to be the standard axial, sagittal, and coronal planes. PMID:20052359

  6. Initial Stage Reference Search : Driver Simulators to Test Shared Controls, Limited Autonomy Vehicle Systems

    Science.gov (United States)

    2015-09-01

    This literature review and reference scanning focuses on the use of driver simulators for semiautonomous (or shared control) vehicle systems (2012present), including related research from other modes of transportation (e.g., rail or aviation). Foc...

  7. DESIGN OF ROBUST NAVIGATION AND STABILIZATION LOOPS OF PRECISION ATTITUDE AND HEADING REFERENCE SYSTEM

    Directory of Open Access Journals (Sweden)

    Olha Sushchenko

    2017-11-01

    Full Text Available Purpose: The paper focuses on problems of design of robust precision attitude and heading reference systems, which can be applied in navigation of marine vehicles. The main goal is to create the optimization procedures for design of navigation and stabilization loops of the multimode gimballed system. The optimization procedure of the navigation loop design is based on the parametric robust H2/H∞-optimization. The optimization procedure of the stabilization loop design is based on the robust structural H∞-synthesis. Methods: To solve the given problem the methods of the robust control system theory and optimization methods are used. Results: The kinematical scheme of the precision gimballed attitude and heading reference system is represented. The parametrical optimization algorithm taking into consideration features of the researched system is given. Method of the mixed sensitivity relative to the researched system design is analyzed. Coefficients of the control laws of navigation loops are obtained based on optimization procedure providing compromise between accuracy and robustness. The robust controller of the stabilization loop was developed based on robust structural synthesis using method of the mixed sensitivity. Simulation of navigation and stabilization processes is carried out. Conclusions: The represented results prove efficiency of the proposed procedures, which can be useful for design of precision navigation systems of the moving vehicles.

  8. Venous, Arterialized-Venous, or Capillary Glucose Reference Measurements for the Accuracy Assessment of a Continuous Glucose Monitoring System.

    Science.gov (United States)

    Kropff, Jort; van Steen, Sigrid C; deGraaff, Peter; Chan, Man W; van Amstel, Rombout B E; DeVries, J Hans

    2017-11-01

    Different reference methods are used for the accuracy assessment of continuous glucose monitoring (CGM) systems. The effect of using venous, arterialized-venous, or capillary reference measurements on CGM accuracy is unclear. We evaluated 21 individuals with type 1 diabetes using a capillary calibrated CGM system. Venous or arterialized-venous reference glucose samples were taken every 15 min at two separate visits and assessed per YSI 2300 STAT Plus. Arterialization was achieved by heated-hand technique. Capillary samples were collected hourly during the venous reference visit. The investigation sequence (venous or arterialized-venous) was randomized. Effectiveness of arterialization was measured by comparing free venous oxygen pressure (PO2) of both visit days. Primary endpoint was the median absolute relative difference (ARD). Median ARD using arterialized-venous reference samples was not different from venous samples (point estimated difference 0.52%, P = 0.181). When comparing the three reference methods, median ARD was also not different over the full glycemic range (venous 9.0% [n = 681], arterialized-venous 8.3% [n = 684], and capillary 8.1% [n = 205], P = 0.216), nor over the separate glucose ranges. Arterialization was successful (PO2 venous 5.4 kPa vs. arterialized-venous 8.9 kPa, P reference measurements did not significantly impact CGM accuracy. Venous reference seems preferable due to its ease of operation.

  9. Development of solid state reference electrodes and pH sensors for monitoring nuclear reactor cooling water systems

    International Nuclear Information System (INIS)

    Hettiarachchi, S.; Makela, K.; Macdonald, D.D.

    1991-01-01

    The growing interest in the electrochemical and corrosion behavior of structural alloys in high temperature aqueous systems has stimulated research in the design and testing of reliable reference electrodes and pH sensors for use in such environments. External reference electrodes have been successfully used in the recent years in high temperature aqueous environments, although their long-term stability is questionable. On the other hand, more reliable pH sensors have been developed by various workers for high temperature applications, the major drawback being their sensitivity to dissolved hydrogen, oxygen and other redox species. This paper describes the development of both solid-state reference electrodes and yttria-stabilized zirconia (YSZ) pH sensors for application in high temperature aqueous systems. (author)

  10. Nuclear emergency response exercises and decision support systems - integrating domestic experience with international reference systems

    International Nuclear Information System (INIS)

    Slavnicu, D.S.; Vamanu, D.V.; Gheorghiu, D.; Acasandrei, V.T.; Slavnicu, E.

    2010-01-01

    The paper glosses on the experience of a research-oriented team routinely involved in emergency preparedness and response management activities, with the assimilation, implementation, and application of decision support systems (DSS) of continental reference in Europe, and the development of supportive, domestic radiological assessment tools. Two exemplary nuclear alert exercises are discussed, along with solutions that emerged during drill planning and execution, to make decision support tools of various origins and strength to work synergistically and complement each other. (authors)

  11. Reference reactor module for NASA's lunar surface fission power system

    International Nuclear Information System (INIS)

    Poston, David I.; Kapernick, Richard J.; Dixon, David D.; Werner, James; Qualls, Louis; Radel, Ross

    2009-01-01

    Surface fission power systems on the Moon and Mars may provide the first US application of fission reactor technology in space since 1965. The Affordable Fission Surface Power System (AFSPS) study was completed by NASA/DOE to determine the cost of a modest performance, low-technical risk surface power system. The AFSPS concept is now being further developed within the Fission Surface Power (FSP) Project, which is a near-term technology program to demonstrate system-level TRL-6 by 2013. This paper describes the reference FSP reactor module concept, which is designed to provide a net power of 40 kWe for 8 years on the lunar surface; note, the system has been designed with technologies that are fully compatible with a Martian surface application. The reactor concept uses stainless-steel based. UO 2 -fueled, pumped-NaK fission reactor coupled to free-piston Stirling converters. The reactor shielding approach utilizes both in-situ and launched shielding to keep the dose to astronauts much lower than the natural background radiation on the lunar surface. The ultimate goal of this work is to provide a 'workhorse' power system that NASA can utilize in near-term and future Lunar and Martian mission architectures, with the eventual capability to evolve to very high power, low mass systems, for either surface, deep space, and/or orbital missions.

  12. Initial testing of a neutron activation analysis system by analysing standard reference materials

    International Nuclear Information System (INIS)

    Suhaimi Hamzah; Roslan Idris; Abdul Khalik Haji Wood; Che Seman Mahmood; Abdul Rahim Mohamad Noor.

    1983-01-01

    This paper describes the data acquisition and processing system in our laboratories (ND6600), the methods of activation analysis and the results obtained from our analysis of IAEA standard reference material (SL-l lake sediments and NBS coal ash 1632a). These standards were analysed in order to check the capability of the system, which was designed in such a way as to enable the user to independently collect and process data from multiple radiation detectors. (author)

  13. System for effluent treatment with particular reference to the reuse of the water

    Energy Technology Data Exchange (ETDEWEB)

    Rolke, O.E.

    1979-01-01

    A system for effluent treatment with particular reference to the reuse of the water consisted of biological treatment, flocculation, filtration, activated carbon adsorption and ion exchange. Such a multistage system is needed to treat wastewaters from coal gasification and coke-oven plants since the effluents, derived from cooling water for scrubbers, waste heat boilers, and heat exchangers, contains high levels of phenols, fatty acids, ammonia, suspended tar oil, and coal particles. A pilot plant, which has been built based on the system, will produce water of sufficient quality for reuse as cooling water. It is hoped that cooling systems for coal gasification plants can be 90% closed circuit.

  14. Development of the Korean Reference Vertical Disposal System Concept for Spent Fuels

    International Nuclear Information System (INIS)

    Lee, J.Y.; Cho, D.K.; Kim, S.G.; Choi, H.J.; Choi, J.W.; Hahn, P.S.

    2006-01-01

    The development of a deep geologic disposal system for the spent fuel from nuclear power plants has been carried out since this program was launched at 1997 in Korea. In ' this paper, a pre-conceptual design of the Korean Reference HLW Vertical disposal System (KRS-V1) is presented. Though no site for the underground repository has yet been specified in Korea, a generic site with granitic rock is considered for reference HLW repository design. Depth of the repository is assumed to be 500 meters. The repository consists of the disposal area, technical rooms with four shafts to connect them to the ground level in the controlled area and technical rooms with an access tunnel and three shafts to connect them to the ground level in the uncontrolled area. Disposal area consists of disposal tunnels, panel tunnels and a central tunnel. The repository will be excavated, operated and backfilled in several phases including an Underground Research Laboratory (URL) phase. The result of this preliminary conceptual design will be used for an evaluation of the feasibility, analyses of the long term safety, information for public communication and a cost estimation etc. (authors)

  15. A Practical Method for Implementing an Attitude and Heading Reference System

    Directory of Open Access Journals (Sweden)

    Rodrigo Munguía

    2014-04-01

    Full Text Available This paper describes a practical and reliable algorithm for implementing an Attitude and Heading Reference System (AHRS. This kind of system is essential for real time vehicle navigation, guidance and control applications. When low cost sensors are used, efficient and robust algorithms are required for performance to be acceptable. The proposed method is based on an Extended Kalman Filter (EKF in a direct configuration. In this case, the filter is explicitly derived from both the kinematic and error models. The selection of this kind of EKF configuration can help in ensuring a tight integration of the method for its use in filter-based localization and mapping systems in autonomous vehicles. Experiments with real data show that the proposed method is able to maintain an accurate and drift-free attitude and heading estimation. An additional result is to show that there is no ostensible reason for preferring that the filter have an indirect configuration over a direct configuration for implementing an AHRS system.

  16. Patients' knowledge and attitude towards therapeutic reference pricing system in Slovenia.

    Science.gov (United States)

    Marđetko, Nika; Kos, Mitja

    2016-10-01

    Background The therapeutic reference pricing (TRP) in Slovenia was implemented for proton pump inhibitors in 2013 and for angiotensin-converting enzyme inhibitors and lipid-lowering medicines in 2014. Objective The study aimed to assess patients' knowledge and attitude towards the TRP system. Moreover, the patients' willingness to pay was evaluated for patients who rejected the substitution of a current medicine within a therapeutic class by the reference medicine for which no co-payment is needed. Setting Invitation of patients to participate in a survey and filling in the first part of the questionnaire was run in the community pharmacies in Slovenia. The second part of the questionnaire was filled in at patients' home. Method A representative sample of 676 patients that had been prescribed at least one medicine from the three therapeutic classes was surveyed. The survey was carried out from 15th May to 15th June 2014 in 40 community pharmacies with the help of the pharmacists, who filled in the first part of the questionnaire in the presence of the patients. The second part of the questionnaire was filled in by 475 patients at home and returned by prepaid mail. Main outcome measure Patients' knowledge of and attitude to the TRP system implemented into Slovenian health care practice. Results Most of the statements describing patient' rights and duties within the TRP system were known by approximately 50 % of the patients. Patients were inhomogeneous in their view about the necessity and benefits of the TRP system, most of them regarded it as an unnecessary burden. Among 50.4 % of the patients who were required to copay for their medicine, 46.7 % accepted and 3.7 % rejected co-payment. The average co-payment was € 6.92, while the expressed average willingness to co-pay was € 10.4 per 3 months of therapy. Conclusion Our results indicate that the implementation of the TRP system and potential upgrades represent a significant challenge for the patients.

  17. Test reference years - meteorological bases for the technical simulation of heating systems and air-conditioning systems

    International Nuclear Information System (INIS)

    Perl, J.

    1991-01-01

    For the FRG (western part) for 12 regions with different climate test reference years (TRY) have been established. The TRYs are used for the simulation of the thermal behaviour of buildings, of the operation of heating and space avc systems, lighting control, solar plants as well as of comparable technical systems. A TRY is a collection of hourly data of important meterological parameters over a whole year. The TRYs include 14 meteorological parameters for temperature, humidity, wind, short- and long-wave radiation, atmospheric pressure, precipitation and description of the weather at that time. A TRY is to correspond to the characteristic weather conditions of the TRY region. (orig.) [de

  18. Venous, Arterialized-Venous, or Capillary Glucose Reference Measurements for the Accuracy Assessment of a Continuous Glucose Monitoring System

    NARCIS (Netherlands)

    Kropff, Jort; van Steen, Sigrid C.; deGraaff, Peter; Chan, Man W.; van Amstel, Rombout B. E.; DeVries, J. Hans

    2017-01-01

    Background: Different reference methods are used for the accuracy assessment of continuous glucose monitoring (CGM) systems. The effect of using venous, arterialized-venous, or capillary reference measurements on CGM accuracy is unclear. Methods: We evaluated 21 individuals with type 1 diabetes

  19. A reference system for the measurement of low-strength magnetic flux density

    International Nuclear Information System (INIS)

    Fiorillo, F.; Durin, G.F.; Rocchino, L.

    2006-01-01

    Magnetic flux density standards traceable to the SI units have been developed at IEN-INRIM, by which dissemination for general measurement and testing activities can be pursued. The reference system covers a range of values extending from μ 0 H∼1T to μ 0 H∼10μT and is centered on the use of NMR magnetometers, calibrated coils, and stable current sources. The relative measuring uncertainty of the system is shown to increases with decreasing the field strength value and it is estimated to range between a few 10 -6 and some 10 -3

  20. Memory systems interaction in the pigeon: working and reference memory.

    Science.gov (United States)

    Roberts, William A; Strang, Caroline; Macpherson, Krista

    2015-04-01

    Pigeons' performance on a working memory task, symbolic delayed matching-to-sample, was used to examine the interaction between working memory and reference memory. Reference memory was established by training pigeons to discriminate between the comparison cues used in delayed matching as S+ and S- stimuli. Delayed matching retention tests then measured accuracy when working and reference memory were congruent and incongruent. In 4 experiments, it was shown that the interaction between working and reference memory is reciprocal: Strengthening either type of memory leads to a decrease in the influence of the other type of memory. A process dissociation procedure analysis of the data from Experiment 4 showed independence of working and reference memory, and a model of working memory and reference memory interaction was shown to predict the findings reported in the 4 experiments. (PsycINFO Database Record (c) 2015 APA, all rights reserved).

  1. Global Reference Tables for Management Information Systems

    Data.gov (United States)

    Social Security Administration — This database is a collection of reference tables that store common information used throughout SSA. These tables standardize code structures and code usage of SSA...

  2. 1-GWh diurnal load-leveling superconducting magnetic energy storage system reference design

    International Nuclear Information System (INIS)

    Hassenzahl, W.V.; Rogers, J.D.

    1979-01-01

    A point reference design has been completed for a 1-GWh Superconducting Magnetic Energy Storage system. The system is for electric utility dirunal load leveling; however, such a device will function to meet much faster power demands including dynamic stabilization. The study has explored several concepts of design not previously considered in the same detail as treated here. Because the study is for a point design, optimization in all respects is not complete. The study examines aspects of the coil design; superconductor supported off of the dewar shell; the dewar shell, its configuration and stresses; the underground excavation and related construction for holding the superconducting coil and its dewar; the helium refrigeration system; the electrical converter system; the vacuum system; the guard coil; and the costs. The report is a condensation of the more comprehensive study which is in the process of being printed

  3. The System For Co-Reference Resolution For Slovenian Texts Analysis and Possibilities of its Use

    Directory of Open Access Journals (Sweden)

    Peter Holozan

    2015-10-01

    Full Text Available Co-reference resolution is an important part of language technologies, but has not yet been developed for Slovenian. There are various types of co-references and the paper focuses on anaphora resolution of personal pronouns. Seven methods, used in combination, were used; the most important one is based on activation. First results are promising, but for more extensive evaluation, Slovenian corpus with marked examples is needed. Co-reference resolution was used in the question answering system Crammer, which can, as a result, answer more questions than before, because it can replace personal pronouns. At the same time, some other improvement were added to Crammer, e.g. answering to individual words and phrases and answering to declarative sentences. Added was also generation of long answers to questions with interrogative particles. Co-reference resolution also improved working of Presis machine translation, especially for determining of gender of pronouns and for disambiguation of attributive subordinate clauses.

  4. Overview of external reference pricing systems in Europe.

    Science.gov (United States)

    Rémuzat, Cécile; Urbinati, Duccio; Mzoughi, Olfa; El Hammi, Emna; Belgaied, Wael; Toumi, Mondher

    2015-01-01

    External reference pricing (ERP) is a price regulation tool widely used by policy makers in the European Union (EU) Member States (MS) to contain drug cost, although in theory, it may contribute to modulate prices up and down. The objective of this article was to summarise and discuss the main findings of part of a large project conducted for the European Commission ('External reference pricing of medicinal products: simulation-based considerations for cross-country coordination'; see www.ec.europa.eu/health/healthcare/docs/erp_reimbursement_medicinal_products_en.pdf) that aimed to provide an overview of ERP systems, both on processes and potential issues in 31 European countries (28 EU MS, Iceland, Norway, and Switzerland). A systematic structured literature review was conducted to identify and characterise the use of ERP in the selected countries, to describe its impact on the prices of pharmaceuticals, and to discuss the possible cross-country coordination issues in EU MS. This research was complemented with a consultation of competent authorities' and international organisations' representatives to address the main issues or uncertainties identified through the literature review. All selected countries applied ERP, except the United Kingdom and Sweden. Twenty-three countries used ERP as the main systematic criterion for pricing. In the majority of European countries, ERP was based on legislated pricing rules with different levels of accuracy. ERP was applied either for all marketed drugs or for specific categories of medicines; it was mainly used for publicly reimbursed medicines. The number of reference countries included in the basket varied from 1 to 31. There was a great variation in the calculation methods used to compute the price; 15 countries used the average price, 7 countries used the lowest price, and 7 countries used other calculation methods. Reported limitations of ERP application included the lack of reliable sources of price information, price

  5. Balinese Frame of Reference

    Directory of Open Access Journals (Sweden)

    I Nyoman Aryawibawa

    2016-04-01

    Full Text Available Abstract: Balinese Frame of Reference. Wassmann and Dasen (1998 did a study on the acquisition of Balinese frames of reference. They pointed out that, in addition to the dominant use of absolute system, the use of relative system was also observed. This article aims at verifying Wassmann and Dasen’ study. Employing monolingual Balinese speakers and using linguistic and non-linguistic tasks, Aryawibawa (2010, 2012, 2015 showed that Balinese subjects used an absolute system dominantly in responding the two tasks, e.g. The man is north/south/east/west of the car. Unlike Wassmann and Dasen’s results, no relative system was used by the subjects in solving the tasks. Instead of the relative system, an intrinsic system was also observed in this study, even though it was unfrequent. The article concludes that the absolute system was dominantly employed by Balinese speakers in describing spatial relations in Balinese. The use of the system seems to affect their cognitive functions.

  6. Top-Down Enterprise Application Integration with Reference Models

    Directory of Open Access Journals (Sweden)

    Willem-Jan van den Heuvel

    2000-11-01

    Full Text Available For Enterprise Resource Planning (ERP systems such as SAP R/3 or IBM SanFrancisco, the tailoring of reference models for customizing the ERP systems to specific organizational contexts is an established approach. In this paper, we present a methodology that uses such reference models as a starting point for a top-down integration of enterprise applications. The re-engineered models of legacy systems are individually linked via cross-mapping specifications to the forward-engineered reference model's specification. The actual linking of reference and legacy models is done with a methodology for connecting (new business objects with (old legacy systems.

  7. A reference sample for investigating the stability of the imaging system of x-ray computed tomography

    International Nuclear Information System (INIS)

    Sun, Wenjuan; Brown, Stephen; Flay, Nadia; McCarthy, Michael; McBride, John

    2016-01-01

    The use of x-ray computed tomography for dimensional measurements associated with engineering applications has flourished in recent years. However, error sources associated with the technology are not well understood. In this paper, a novel two-sphere reference sample has been developed and used to investigate the stability of the imaging system that consists of an x-ray tube and a detector. In contrast with other research work reported, this work considered relative positional variation along the x -, y - and z -axes. This sample is a significant improvement over the one sphere sample proposed previously, which can only be used to observe the stability of the imaging system along x - and y -axes. Temperature variations of different parts of the system have been monitored and the relationship between temperature variations and x-ray image stability has been studied. Other effects that may also influence the stability of the imaging system have been discussed. The proposed reference sample and testing method are transferable to other types of x-ray computed tomography systems, for example, systems with transmission targets and systems with sub-micrometre focal spots. (paper)

  8. National Health and Nutrition Examination Survey whole-body dual-energy X-ray absorptiometry reference data for GE Lunar systems.

    Science.gov (United States)

    Fan, Bo; Shepherd, John A; Levine, Michael A; Steinberg, Dee; Wacker, Wynn; Barden, Howard S; Ergun, David; Wu, Xin P

    2014-01-01

    The National Health and Nutrition Examination Survey (NHANES 1999-2004) includes adult and pediatric comparisons for total body bone and body composition results. Because dual-energy x-ray absorptiometry (DXA) measurements from different manufacturers are not standardized, NHANES reference values currently are applicable only to a single make and model of Hologic DXA system. The purpose of this study was to derive body composition reference curves for GE Healthcare Lunar DXA systems. Published values from the NHANES 1999-2004 survey were acquired from the Centers for Disease Control and Prevention website. Using previously reported cross-calibration equations between Hologic and GE-Lunar, we converted the total body and regional bone and soft-tissue measurements from NHANES 1999-2004 to GE-Lunar values. The LMS (LmsChartMaker Pro Version 3.5) curve fitting method was used to generate GE-Lunar reference curves. Separate curves were generated for each sex and ethnicity. The reference curves were also divided into pediatric (≤20 years old) and adult (>20 years old) groups. Adult reference curves were derived as a function of age. Additional relationships of pediatric DXA values were derived as a function of height, lean mass, and bone area. Robustness was tested between Hologic and GE-Lunar Z-score values. The NHANES 1999-2004 survey included a sample of 20,672 participants' (9630 female) DXA scans. A total of 8056 participants were younger than 20 yr and were included in the pediatric reference data set. Participants enrolled in the study who weighed more than 136 kg (over scanner table limit) were excluded. The average Z-scores comparing the new GE-Lunar reference curves are close to zero, and the standard deviation of the Z-scores are close to one for all variables. As expected, all measurements on the GE-Lunar reference curves for participants younger than 20 yr increase monotonically with age. In the adult population, most of the curves are constant at younger

  9. Reference design of the power supply system for the resistive-wall-mode control in JT-60SA

    Energy Technology Data Exchange (ETDEWEB)

    Ferro, Alberto, E-mail: alberto.ferro@igi.cnr.it [Consorzio RFX, C.so Stati Uniti 4, 35127 Padova (Italy); Gaio, Elena [Consorzio RFX, C.so Stati Uniti 4, 35127 Padova (Italy); Novello, Luca [Fusion for Energy, Broader Development of Fusion Department, Boltzmannstr 2, 85748 Garching (Germany); Matsukawa, Makoto; Shimada, Katsuhiro; Kawamata, Yoichi; Takechi, Manabu [Japan Atomic Energy Agency, Naka Fusion Institute, 801-1 Mukoyama, Naka, Ibaraki 311-019 (Japan)

    2015-10-15

    Highlights: • In JT-60SA, a power supply system (RWM-PS) will feed 18 coils to control the RWMs. • One power amplifier per coil will follow an arbitrary real-time reference. • Very fast dynamics is required (current bandwidth: 3 kHz; latency: 50 μs). • The requirements of the RWM-PS are updated and design solutions discussed. • The reference design of the RWM-PS is based on H-bridges operated at 20 – 30 kHz. - Abstract: The mission of JT-60SA, the satellite Tokamak under construction in Naka (Japan), includes the attainment of steady-state high-beta plasmas. For this purpose, an active control system based on 18 in-vessel sector coils (SC) is foreseen to suppress the resistive wall modes (RWM). Each coil will be independently fed by a dedicated converter, rated for 300 A and 240 V, which has to produce the required current/voltage following in real time the reference provided by the JT-60SA MHD Controller. To minimize the current rating, these converters shall be sufficiently fast to avoid an excessive growth of the RWM. This requires a very high dynamic performance, largely beyond that of standard industrial applications. This paper firstly reports the latest results of the studies on the requirements of the RWM active control system. Then, the reference design of the power supply system is presented, including the ac/dc conversion stage, the fast converters and the control section. The advantages of the proposed scheme are discussed and the main electrical parameters are presented.

  10. Data reference and retrieval system for Richton Dome, Mississippi: annual status report for fiscal year 1982

    International Nuclear Information System (INIS)

    1983-06-01

    The Geologic Data Base for Richton Dome, Mississippi, was updated and expanded in FY 82 to support National Waste Terminal Storage characterization studies. The existing data base, consisting of references, maps, remote sensing data, and well-boring information, was inventoried to catalog the data acquired during previous studies. This catalog is maintained on Ertec's in-house computer. Bibliographies of selected documents were reviewed and commercial data bases were searched to identify additional references pertinent to future geologic characterization studies to be added to the data base. In addition to the references, selected preliminary safety analysis report sections and associated reports for nuclear generating stations, oil and gas well completion records, and US Geological Survey System 2000 hydrologic data were obtained for specific areas of Mississippi and Alabama. These additional data and references provide a comprehensive and current data base for Richton Dome

  11. Reference Models of Information Systems Constructed with the use of Technologies of Cloud Calculations

    Directory of Open Access Journals (Sweden)

    Darya Sergeevna Simonenkova

    2013-09-01

    Full Text Available The subject of the research is analysis of various models of the information system constructed with the use of technologies of cloud calculations. Analysis of models is required for constructing a new reference model which will be used for develop a security threats model.

  12. Determining the direction of a geometrical/optical reference axis in the coordinate system of a triaxial magnetometer sensor

    DEFF Research Database (Denmark)

    Primdahl, Fritz; Brauer, Peter; Merayo, José M.G.

    2002-01-01

    optical or geometrical axes in order to be able to determine the precise orientation of the magnetic coordinate axes in an external reference system. Two methods for determining a reference axis in the sensor coordinates are discussed: (1) using a triaxial coil facility to measure the sensor orientation...

  13. Setting reference targets

    International Nuclear Information System (INIS)

    Ruland, R.E.

    1997-04-01

    Reference Targets are used to represent virtual quantities like the magnetic axis of a magnet or the definition of a coordinate system. To explain the function of reference targets in the sequence of the alignment process, this paper will first briefly discuss the geometry of the trajectory design space and of the surveying space, then continue with an overview of a typical alignment process. This is followed by a discussion on magnet fiducialization. While the magnetic measurement methods to determine the magnetic centerline are only listed (they will be discussed in detail in a subsequent talk), emphasis is given to the optical/mechanical methods and to the task of transferring the centerline position to reference targets

  14. Comparison of the TLDA with the Nanodrop and the reference Qubit system

    Energy Technology Data Exchange (ETDEWEB)

    O' Neill, M; Arthure, K; Riedel, S; McMillan, ND [Drop Technology Ltd., Tallaght Business Park, Whitestown, Dublin 24 (Ireland); McPartlin, J, E-mail: martina.oneill@droptechnology.com [Vitamin Research Unit, Department of Clinical Medicine, Sir Patrick Duns Laboratory, CPL, St. James' s Hospital, Dublin 8 (Ireland)

    2011-08-17

    The TLDA (transmitted light drop analyser) is a new microvolume UV-visible drop spectrophotometer new to the market. Assays were compared between a TLDA, NanoDrop and the Qubit system which is based on the gold standard for DNA assay, PicoGreen. The evaluation was carried out by the Trinity Biobank in St. James Hospital, Dublin on Buccal swabs and Blood samples. The data is discussed in this paper. The Qubit system is seen as the reference method in most studies as this is believed to provide more accurate results than UV absorbance methods because it distinguishes between DNA, RNA, free nucleotides, and other contaminants. The Qubit system uses fluorescent dyes to measure the concentration of the molecule of interest. The results compare both the spectrophotometric methods against the Qubit fluorescence technique.

  15. Development of picture quality monitoring system for IPTV service based on the reduced reference framework

    Science.gov (United States)

    Sugimoto, Osamu; Kawada, Ryoichi; Koike, Atsushi

    2006-01-01

    The authors developed a software-based realtime IPTV monitoring system based on Reduced Reference framework, and evaluated the proposed system. One of the quality issues of the IPTV service is the picture quality degradation caused by packet loss. The proposed system precisely estimates the PSNR of the corrupted received picture by extracting and comparing image features from transmission and receiver side. Computer simulations show that PSNR estimation with a 0.945 correlation coefficient at a data channel bitrate of 36kbps is possible using the proposed system.

  16. Development of a reference liquid scintillation cocktail

    CSIR Research Space (South Africa)

    Van Wyn Gaardt, WM

    2006-02-01

    Full Text Available A reference system that would allow national laboratories to compare their activity measurements of non-gamma-emitting radionuclides at any time is currently being developed. The system requires a non-commercial reference-liquid scintillation...

  17. Communication: Density functional theory model for multi-reference systems based on the exact-exchange hole normalization.

    Science.gov (United States)

    Laqua, Henryk; Kussmann, Jörg; Ochsenfeld, Christian

    2018-03-28

    The correct description of multi-reference electronic ground states within Kohn-Sham density functional theory (DFT) requires an ensemble-state representation, employing fractionally occupied orbitals. However, the use of fractional orbital occupation leads to non-normalized exact-exchange holes, resulting in large fractional-spin errors for conventional approximative density functionals. In this communication, we present a simple approach to directly include the exact-exchange-hole normalization into DFT. Compared to conventional functionals, our model strongly improves the description for multi-reference systems, while preserving the accuracy in the single-reference case. We analyze the performance of our proposed method at the example of spin-averaged atoms and spin-restricted bond dissociation energy surfaces.

  18. Communication: Density functional theory model for multi-reference systems based on the exact-exchange hole normalization

    Science.gov (United States)

    Laqua, Henryk; Kussmann, Jörg; Ochsenfeld, Christian

    2018-03-01

    The correct description of multi-reference electronic ground states within Kohn-Sham density functional theory (DFT) requires an ensemble-state representation, employing fractionally occupied orbitals. However, the use of fractional orbital occupation leads to non-normalized exact-exchange holes, resulting in large fractional-spin errors for conventional approximative density functionals. In this communication, we present a simple approach to directly include the exact-exchange-hole normalization into DFT. Compared to conventional functionals, our model strongly improves the description for multi-reference systems, while preserving the accuracy in the single-reference case. We analyze the performance of our proposed method at the example of spin-averaged atoms and spin-restricted bond dissociation energy surfaces.

  19. Uvođenje novih geodetskih referentnih sistema u Bosni i Hercegovini : Introduction of a new geodetic reference systems in Bosnia and Herzegovina

    Directory of Open Access Journals (Sweden)

    Šeho Zimić

    2017-12-01

    Full Text Available The introduction of a new reference system in Bosnia and Herzegovina is not only a necessity, but an obligation imposed by the United Nations (UN and the European Union (EU. At the General Assembly on February 26, 2015, the UN has adopted a resolution titled "Global Geodetic Reference Frame for Sustainable Development - GGRF", which for the first time raise the geodetic issue as a political issue at such a high level. The resolution highlights the strong need for more precise positioning and navigation from the use of smartphones to the study of climate changes, population migrations and other scientific researches of relevance to the whole world (http://www.unggrf.org/. All this is not possible without a global exchange of geodata and a common global geodetic reference system. Through the Inspire Directive, the EU has clearly specified which coordinate and heights systems are being applied in Europe. The countries in the region have adopted the European terrestrial reference system ETRS89 as a new reference system in their legislation. Through the EUREF campaign BALKAN98 and the introduction of the Network of permanent GNSS stations Bosnia and Herzegovina has joined the famil

  20. 1-GWh diurnal load-leveling Superconducting Magnetic Energy Storage system reference design

    International Nuclear Information System (INIS)

    Rogers, J.D.; Hassenzahl, W.V.; Schermer, R.I.

    1979-09-01

    A point reference design has been completed for a 1-GWh Superconducting Magnetic Energy Storage system. The system is for electric utility diurnal load-leveling but can also function to meet much faster power demands including dynamic stabilization. This study explores several concepts of design not previously considered in the same detail as treated here. Because the study is for a point design, optimization in all respects is not complete. This report examines aspects of the coil, the superconductor supported off of the dewar shell, the dewar shell, and its configuration and stresses, the underground excavation and construction for holding the superconducting coil and its dewar, the helium refrigeration system, the electrical converter system, the vacuum system, the guard coil, and the costs. This report is divided into two major portions. The first is a general treatment of the work and the second is seven detailed technical appendices issued as separate reports. The information presented on the aluminum stabilizer for the conductor, on the excavation, and on the converter is based upon industrial studies contracted for this work

  1. Program reference schedule baseline

    International Nuclear Information System (INIS)

    1986-07-01

    This Program Reference Schedule Baseline (PRSB) provides the baseline Program-level milestones and associated schedules for the Civilian Radioactive Waste Management Program. It integrates all Program-level schedule-related activities. This schedule baseline will be used by the Director, Office of Civilian Radioactive Waste Management (OCRWM), and his staff to monitor compliance with Program objectives. Chapter 1 includes brief discussions concerning the relationship of the PRSB to the Program Reference Cost Baseline (PRCB), the Mission Plan, the Project Decision Schedule, the Total System Life Cycle Cost report, the Program Management Information System report, the Program Milestone Review, annual budget preparation, and system element plans. Chapter 2 includes the identification of all Level 0, or Program-level, milestones, while Chapter 3 presents and discusses the critical path schedules that correspond to those Level 0 milestones

  2. The University of Texas at Arlington's Virtual Reference Service: An Evaluation by the Reference Staff

    Science.gov (United States)

    Casebier, Katherine D.

    2006-01-01

    The University of Texas at Arlington's Library began using an online chat reference in 2002. The service, called Collaborative Digital Reference Service, later became "Ask a Librarian." Slightly over one year later, the library joined the University of Texas System's "Ask a Librarian" service. Both services are powered by…

  3. rf reference line for PEP

    International Nuclear Information System (INIS)

    Schwarz, H.D.; Weaver, J.N.

    1979-03-01

    A rf phase reference line in 6 segments around the 2200 meter circumference PEP storage ring is described. Each segment of the reference line is phase stabilized by its own independent feedback system, which uses an amplitude modulated reflection from the end of each line. The modulation is kept small and decoupled from the next segment to avoid crosstalk and significant modulation of the rf drive signal. An error evaluation of the system is made. The technical implementation and prototype performance are described. Prototype tests indicate that the phase error around the ring can be held below 1 degree with this relatively simple system

  4. rf reference line for PEP

    Energy Technology Data Exchange (ETDEWEB)

    Schwarz, H.D.; Weaver, J.N.

    1979-03-01

    A rf phase reference line in 6 segments around the 2200 meter circumference PEP storage ring is described. Each segment of the reference line is phase stabilized by its own independent feedback system, which uses an amplitude modulated reflection from the end of each line. The modulation is kept small and decoupled from the next segment to avoid crosstalk and significant modulation of the rf drive signal. An error evaluation of the system is made. The technical implementation and prototype performance are described. Prototype tests indicate that the phase error around the ring can be held below 1 degree with this relatively simple system.

  5. Mobility-based Time References for Wireless Sensor Networks

    CERN Document Server

    Sebastiano, Fabio; Makinwa, Kofi A A

    2013-01-01

     This book describes the use of low-power low-cost and extremely small radios to provide essential time reference for wireless sensor networks.  The authors explain how to integrate such radios in a standard CMOS process to reduce both cost and size, while focusing on the challenge of designing a fully integrated time reference for such radios. To enable the integration of the time reference, system techniques are proposed and analyzed, several kinds of integrated time references are reviewed, and mobility-based references are identified as viable candidates to provide the required accuracy at low-power consumption. Practical implementations of a mobility-based oscillator and a temperature sensor are also presented, which demonstrate the required accuracy over a wide temperature range, while drawing 51-uW from a 1.2-V supply in a 65-nm CMOS process. Provides system analysis to understand requirements for time/frequency accuracy in wireless sensor networks; Describes system optimization for time references i...

  6. Reference frame for Product Configuration

    DEFF Research Database (Denmark)

    Ladeby, Klaes Rohde; Oddsson, Gudmundur Valur

    2011-01-01

    a reference frame for configuration that permits 1) a more precise understanding of a configuration system, 2) a understanding of how the configuration system relate to other systems, and 3) a definition of the basic concepts in configuration. The total configuration system, together with the definition...

  7. Examining egocentric and allocentric frames of reference in virtual space systems

    NARCIS (Netherlands)

    Friedman, A.

    2005-01-01

    The aim of this paper is to examine the egocentric and allocentric frames of reference, through evidence from both gesture and linguistic communication. The action of frames of reference, helps the user refer to the agent as a base for movement or to the object as a guiding point. We will show that

  8. Clinical Application of Different Surgical Navigation Systems in Complex Craniomaxillofacial Surgery: The Use of Multisurface 3-Dimensional Images and a 2-Plane Reference System.

    Science.gov (United States)

    Liu, Tom J; Ko, An-Ta; Tang, Yueh-Bih; Lai, Hong-Shiee; Chien, Hsiung-Fei; Hsieh, Thomas Mon-Hsian

    2016-04-01

    Intraoperative navigation is a tool that provides surgeons with real-time guidance based on patients' preoperative imaging studies. The application of intraoperative navigation to neurosurgery and otolaryngology has been well documented; however, only isolated reports have analyzed its potential in the field of craniomaxillofacial surgery. From November 2010 to July 2014, 15 patients were operated on for complex craniomaxillofacial surgery with assistance by 3 different navigation systems, which used either infrared or electromagnetic technologies. We imported fine-cut (0.625-mm) computed tomographic scan images of the patients to the navigation systems whose software processed them into multisurface 3-dimentional models used as guiding material for the surgical navigation. We also developed a simple "2-plane reference system" to ensure that the final results were symmetric to the normal half of the face. Appearance outcome was evaluated by questionnaire. Of these 15 cases, 3 cases were performed with infrared-based navigation, and the remaining 12 cases were accomplished by electromagnetic technology. Most of these cases resulted in satisfactory outcomes after tumor resection, posttraumatic reconstruction, and postablative reconstruction. Navigation systems offer highly valuable intraoperative assistance in complex craniomaxillofacial surgery. Not only can these systems pinpoint deep-seated lesions as neurosurgeons or otolaryngologists do, but they can also use a simple 2-plane reference system for accurate bone alignment. Moreover, advancements in multisurface 3-D models provide us more reliable intuitive image guidance. The application of electromagnetic technology, with its smaller reference obviation of the line-of-sight problem, makes the manipulation of craniomaxillofacial surgery more comfortable.

  9. A Nonlinear Attitude Estimator for Attitude and Heading Reference Systems Based on MEMS Sensors

    DEFF Research Database (Denmark)

    Wang, Yunlong; Soltani, Mohsen; Hussain, Dil muhammed Akbar

    2016-01-01

    In this paper, a nonlinear attitude estimator is designed for an Attitude Heading and Reference System (AHRS) based on Micro Electro-Mechanical Systems (MEMS) sensors. The design process of the attitude estimator is stated with detail, and the equilibrium point of the estimator error model...... the problems in previous research works. Moreover, the estimation of MEMS gyroscope bias is also inclueded in this estimator. The designed nonlinear attitude estimator is firstly tested in simulation environment and then implemented in an AHRS hardware for further experiments. Finally, the attitude estimation...

  10. Endogenous versus exogenous generic reference pricing for pharmaceuticals.

    Science.gov (United States)

    Antoñanzas, F; Juárez-Castelló, C A; Rodríguez-Ibeas, R

    2017-12-01

    In this paper we carry out a vertical differentiation duopoly model applied to pharmaceutical markets to analyze how endogenous and exogenous generic reference pricing influence competition between generic and branded drugs producers. Unlike the literature, we characterize for the exogenous case the equilibrium prices for all feasible relevant reference prices. Competition is enhanced after the introduction of a reference pricing system. We also compare both reference pricing systems on welfare grounds, assuming two different objective functions for health authorities: (i) standard social welfare and (ii) gross consumer surplus net of total pharmaceutical expenditures. We show that regardless of the objective function, health authorities will never choose endogenous reference pricing. When health authorities are paternalistic, the exogenous reference price that maximizes standard social welfare is such that the price of the generic drug is the reference price while the price of the branded drug is higher than the reference price. When health authorities are not paternalistic, the optimal exogenous reference price is such that the price of the branded drug is the reference price while the price of the generic drug is lower than the reference price.

  11. Characterisation of pristine Polish river systems and their use as reference conditions for Dutch river systems

    NARCIS (Netherlands)

    Nijboer, R.C.; Verdonschot, P.F.M.; Piechocki, A.; Tonczyk, G.; Klukowska, M.

    2006-01-01

    A central feature of the European Water Framework Directive are the reference conditions. The ecological quality status is determined by calculating the distance between the present situation and the reference conditions. To describe reference conditions the natural variation of biota in pristine

  12. Quantum reference frames and their applications to thermodynamics.

    Science.gov (United States)

    Popescu, Sandu; Sainz, Ana Belén; Short, Anthony J; Winter, Andreas

    2018-07-13

    We construct a quantum reference frame, which can be used to approximately implement arbitrary unitary transformations on a system in the presence of any number of extensive conserved quantities, by absorbing any back action provided by the conservation laws. Thus, the reference frame at the same time acts as a battery for the conserved quantities. Our construction features a physically intuitive, clear and implementation-friendly realization. Indeed, the reference system is composed of the same types of subsystems as the original system and is finite for any desired accuracy. In addition, the interaction with the reference frame can be broken down into two-body terms coupling the system to one of the reference frame subsystems at a time. We apply this construction to quantum thermodynamic set-ups with multiple, possibly non-commuting conserved quantities, which allows for the definition of explicit batteries in such cases.This article is part of a discussion meeting issue 'Foundations of quantum mechanics and their impact on contemporary society'. © 2018 The Author(s).

  13. Application of project management methodology in design management of nuclear safety related structure

    International Nuclear Information System (INIS)

    Chen Mao

    2004-01-01

    This paper focuses on the application of project management methodology in the design management of Nuclear Safety Related Structure (NSRS), considering the design management features of its civil construction. Based on the experiences from the management of several projects, the project management triangle is proposed to be used in the management, to well treat the position of design interface in the project management. Some other management methods are also proposed

  14. Verification of SAP reference models

    NARCIS (Netherlands)

    Dongen, van B.F.; Jansen-Vullers, M.H.; Aalst, van der W.M.P.; Benatallah, B.; Casati, F.

    2005-01-01

    To configure a process-aware information system (e.g., a workflow system, an ERP system), a business model needs to be transformed into an executable process model. Due to similarities in these transformations for different companies, databases with reference models, such as ARIS for MySAP, have

  15. Remote reference processing in MT survey using GPS clock; MT ho ni okeru GPS wo mochiita jikoku doki system

    Energy Technology Data Exchange (ETDEWEB)

    Yamane, K; Inoue, J; Takasugi, S [Geothermal Energy Research and Development Co. Ltd., Tokyo (Japan); Kosuge, S [DRICO Co. Ltd., Tokyo (Japan)

    1996-05-01

    A report is given about the application of a synchronizing system using clock signals from GPS satellites to a remote reference method which is a technique to reject noise from the MT method. This system uses the C/A code out of the L1 band waves from NAVSTAR/GPS satellites. The new system was operated in MT method-using investigations conducted at China Peninsula, Aichi Prefecture, and Izu Peninsula, Shizuoka Prefecture, with the reference points placed several 100km away in Iwate Prefecture on both occasions. It was found as the result that it is basically possible to catch signals from the GPS at any place, that the signals are accurate enough to be applied to time synchronization for the MT method, and that the signals assure a far remote reference method with a separation of several 100km between the sites involved. The referencing process at high frequencies whose feasibility had been doubted proved a success when highly correlated signals were exchanged between two stations over a distance of several 100km. 5 refs., 9 figs.

  16. Robust model reference adaptive output feedback tracking for uncertain linear systems with actuator fault based on reinforced dead-zone modification.

    Science.gov (United States)

    Bagherpoor, H M; Salmasi, Farzad R

    2015-07-01

    In this paper, robust model reference adaptive tracking controllers are considered for Single-Input Single-Output (SISO) and Multi-Input Multi-Output (MIMO) linear systems containing modeling uncertainties, unknown additive disturbances and actuator fault. Two new lemmas are proposed for both SISO and MIMO, under which dead-zone modification rule is improved such that the tracking error for any reference signal tends to zero in such systems. In the conventional approach, adaption of the controller parameters is ceased inside the dead-zone region which results tracking error, while preserving the system stability. In the proposed scheme, control signal is reinforced with an additive term based on tracking error inside the dead-zone which results in full reference tracking. In addition, no Fault Detection and Diagnosis (FDD) unit is needed in the proposed approach. Closed loop system stability and zero tracking error are proved by considering a suitable Lyapunov functions candidate. It is shown that the proposed control approach can assure that all the signals of the close loop system are bounded in faulty conditions. Finally, validity and performance of the new schemes have been illustrated through numerical simulations of SISO and MIMO systems in the presence of actuator faults, modeling uncertainty and output disturbance. Copyright © 2015 ISA. Published by Elsevier Ltd. All rights reserved.

  17. Effect of long-lived containers on the postclosure performance of a reference disposal system

    International Nuclear Information System (INIS)

    Goodwin, B.W.; Hajas, W.C.; LeNeveu, D.M.

    1996-05-01

    The concept for disposal of Canada's nuclear fuel waste involves isolating the waste in corrosion-resistant containers emplaced in a scaled vault at a depth of 500 to 1000 m in plutonic rock of the Canadian Shield. The concept permits a choice of methods, materials, site locations, and designs. The technical feasibility of this concept and its impact on the environment and human health are summarized in an Environmental Impact Statement (AECL 1994a,b), supported by nine detailed reference documents (Davis et al. 1993; Davison et al. 1994a,b; Goodwin et al. 1994; Greber et al. 1994; Grondin et al. 1994; Johnson et al. 1994a,b; Simmons and Baumgartner 1994). In the assessment of the reference disposal system, we assumed the containers encapsulating the nuclear fuel waste were constructed from Grade-2 titanium. In this report, we investigate the effect of a different choice, and assume the use of long-lived containers constructed from materials such as high-purity copper or Grades-12 or -16 titanium alloys. These alternative materials would provide much longer periods of protection, based on the expectation that the only container failure mechanism, for times up to 10 5 a, involves initial fabrication defects. We explore the effects of long-lived containers for the same vault layout and orientation that were assumed for the reference disposal vault. We also explore effects for two less favourable situations, in which the vault is closer to a nearby fracture zone and in which the vault is extended to have emplacement rooms on both sides of the fracture zone. Our analyses use the probabilistic assessment computer code, SYVAC3-CC3, an acronym for SYstems Variability Analysis Code, generation 3. with a system model describing the Canadian Concept, generation 3, for the disposal of nuclear fuel waste. The input data for the code have been adjusted to approximate the expected protection characteristics of alternative container materials. (author). 31 refs., 1 tab., 16 figs

  18. A Reference Architecture for Space Information Management

    Science.gov (United States)

    Mattmann, Chris A.; Crichton, Daniel J.; Hughes, J. Steven; Ramirez, Paul M.; Berrios, Daniel C.

    2006-01-01

    We describe a reference architecture for space information management systems that elegantly overcomes the rigid design of common information systems in many domains. The reference architecture consists of a set of flexible, reusable, independent models and software components that function in unison, but remain separately managed entities. The main guiding principle of the reference architecture is to separate the various models of information (e.g., data, metadata, etc.) from implemented system code, allowing each to evolve independently. System modularity, systems interoperability, and dynamic evolution of information system components are the primary benefits of the design of the architecture. The architecture requires the use of information models that are substantially more advanced than those used by the vast majority of information systems. These models are more expressive and can be more easily modularized, distributed and maintained than simpler models e.g., configuration files and data dictionaries. Our current work focuses on formalizing the architecture within a CCSDS Green Book and evaluating the architecture within the context of the C3I initiative.

  19. Software reference for SaTool - a Tool for Structural Analysis of Automated Systems

    DEFF Research Database (Denmark)

    Lorentzen, Torsten; Blanke, Mogens

    2004-01-01

    This software reference details the functions of SaTool – a tool for structural analysis of technical systems. SaTool is intended used as part of an industrial systems design cycle. Structural analysis is a graph-based technique where principal relations between variables express the system’s...... of the graph. SaTool makes analysis of the structure graph to provide knowledge about fundamental properties of the system in normal and faulty conditions. Salient features of SaTool include rapid analysis of possibility to diagnose faults and ability to make autonomous recovery should faults occur........ The list of such variables and functional relations constitute the system’s structure graph. Normal operation means all functional relations are intact. Should faults occur, one or more functional relations cease to be valid. In a structure graph, this is seen as the disappearance of one or more nodes...

  20. Reference reactor module for NASA's lunar surface fission power system

    Energy Technology Data Exchange (ETDEWEB)

    Poston, David I [Los Alamos National Laboratory; Kapernick, Richard J [Los Alamos National Laboratory; Dixon, David D [Los Alamos National Laboratory; Werner, James [INL; Qualls, Louis [ORNL; Radel, Ross [SNL

    2009-01-01

    Surface fission power systems on the Moon and Mars may provide the first US application of fission reactor technology in space since 1965. The Affordable Fission Surface Power System (AFSPS) study was completed by NASA/DOE to determine the cost of a modest performance, low-technical risk surface power system. The AFSPS concept is now being further developed within the Fission Surface Power (FSP) Project, which is a near-term technology program to demonstrate system-level TRL-6 by 2013. This paper describes the reference FSP reactor module concept, which is designed to provide a net power of 40 kWe for 8 years on the lunar surface; note, the system has been designed with technologies that are fully compatible with a Martian surface application. The reactor concept uses stainless-steel based. UO{sub 2}-fueled, pumped-NaK fission reactor coupled to free-piston Stirling converters. The reactor shielding approach utilizes both in-situ and launched shielding to keep the dose to astronauts much lower than the natural background radiation on the lunar surface. The ultimate goal of this work is to provide a 'workhorse' power system that NASA can utilize in near-term and future Lunar and Martian mission architectures, with the eventual capability to evolve to very high power, low mass systems, for either surface, deep space, and/or orbital missions.

  1. Microgrid cyber security reference architecture.

    Energy Technology Data Exchange (ETDEWEB)

    Veitch, Cynthia K.; Henry, Jordan M.; Richardson, Bryan T.; Hart, Derek H.

    2013-07-01

    This document describes a microgrid cyber security reference architecture. First, we present a high-level concept of operations for a microgrid, including operational modes, necessary power actors, and the communication protocols typically employed. We then describe our motivation for designing a secure microgrid; in particular, we provide general network and industrial control system (ICS)-speci c vulnerabilities, a threat model, information assurance compliance concerns, and design criteria for a microgrid control system network. Our design approach addresses these concerns by segmenting the microgrid control system network into enclaves, grouping enclaves into functional domains, and describing actor communication using data exchange attributes. We describe cyber actors that can help mitigate potential vulnerabilities, in addition to performance bene ts and vulnerability mitigation that may be realized using this reference architecture. To illustrate our design approach, we present a notional a microgrid control system network implementation, including types of communica- tion occurring on that network, example data exchange attributes for actors in the network, an example of how the network can be segmented to create enclaves and functional domains, and how cyber actors can be used to enforce network segmentation and provide the neces- sary level of security. Finally, we describe areas of focus for the further development of the reference architecture.

  2. Realization of a reference system for the generation radon 222

    International Nuclear Information System (INIS)

    Guelin, M.

    1990-11-01

    After some general considerations on radon and its calibration techniques, the methods and technologies developed in order to realize a reference system for the generation of radon 222 are presented. Two original patented techniques have been developed. The former technique deals with the realization of radon 222 solid sources from radium 226 deposit on acrylic fibres. This new technology offers the advantage of very quickly obtaining a constant emission rate near to 100%. The latter technique deals with the standard measurement of radon 222 volumic activity via gamma spectrometry of its short-lived daughters. This new procedure is the only one allowing to relate this measure to gaseous standards. An aeraulic/ventilation circuit makes it possible to calibrate the radon measurement instrumentation within a wide volumic activity range from to 4 to 4 000 Bq/m 3

  3. Dosimetric methodology and reference system for diagnostic level X radiation

    International Nuclear Information System (INIS)

    Potiens, Maria da Penha Albuquerque

    1999-01-01

    Several methodologies for the calibration of diagnostic radiology instruments were developed and established at the Calibration Laboratory of IPEN. These established radiation qualities are recommended by international standards. The methods may be used in the calibration procedures of survey meters used in radiation protection measurements (scattered radiation), instruments used in direct beams (attenuated and non attenuated beams) and quality control instruments. A reference system was proposed using two identical ionization chambers developed at IPEN. They differ only by the collecting electrode material, one of aluminium and the other of graphite. The different energetic dependence of the chamber's response provided a ratio related to the tube potential. The variation of only 0.28%, from 14.3 to 111 keV, on the energetic dependence of the graphite electrode chamber, provided the possibility of air kerma rate determination in the studied radiation beams. (author)

  4. Disposable Miniaturized Screen‐Printed pH and Reference Electrodes for Potentiometric Systems

    DEFF Research Database (Denmark)

    Musa, Arnaud Emmanuel; del Campo, Francisco Javier; Abramova, Natalia

    2011-01-01

    This work describes the development of a miniaturized potentiometric system comprising a miniaturized quasi‐reference electrode (QRE) coupled to a solid‐state ion‐selective electrode (ISE) for the monitoring of pH. We describe the optimization of materials and fabrication processes including screen‐printing...... electrode) that can be used continuously for a period of not less than 7 days in aqueous solutions. Curing the Ag/AgCl pastes during 20 minutes at 120 °C after printing allowed the QREs to display excellent potential stability, as demonstrated by an open‐circuit‐potential standard deviation of ±1.2 mV over...

  5. Method of collective variables with reference system for the grand canonical ensemble

    International Nuclear Information System (INIS)

    Yukhnovskii, I.R.

    1989-01-01

    A method of collective variables with special reference system for the grand canonical ensemble is presented. An explicit form is obtained for the basis sixth-degree measure density needed to describe the liquid-gas phase transition. Here the author presents the fundamentals of the method, which are as follows: (1) the functional form for the partition function in the grand canonical ensemble; (2) derivation of thermodynamic relations for the coefficients of the Jacobian; (3) transition to the problem on an adequate lattice; and (4) obtaining of the explicit form for the functional of the partition function

  6. Systems analysis programs for hands-on integrated reliability evaluations (SAPHIRE) version 5.0, technical reference manual

    International Nuclear Information System (INIS)

    Russell, K.D.; Atwood, C.L.; Galyean, W.J.; Sattison, M.B.; Rasmuson, D.M.

    1994-07-01

    The Systems Analysis Programs for Hands-on Integrated Reliability Evaluations (SAPHIRE) refers to a set of several microcomputer programs that were developed to create and analyze probabilistic risk assessments (PRAs), primarily for nuclear power plants. This volume provides information on the principles used in the construction and operation of Version 5.0 of the Integrated Reliability and Risk Analysis System (IRRAS) and the System Analysis and Risk Assessment (SARA) system. It summarizes the fundamental mathematical concepts of sets and logic, fault trees, and probability. This volume then describes the algorithms that these programs use to construct a fault tree and to obtain the minimal cut sets. It gives the formulas used to obtain the probability of the top event from the minimal cut sets, and the formulas for probabilities that are appropriate under various assumptions concerning repairability and mission time. It defines the measures of basic event importance that these programs can calculate. This volume gives an overview of uncertainty analysis using simple Monte Carlo sampling or Latin Hypercube sampling, and states the algorithms used by these programs to generate random basic event probabilities from various distributions. Further references are given, and a detailed example of the reduction and quantification of a simple fault tree is provided in an appendix

  7. CCF analysis of high redundancy systems safety/relief valve data analysis and reference BWR application

    International Nuclear Information System (INIS)

    Mankamo, T.; Bjoere, S.; Olsson, Lena

    1992-12-01

    Dependent failure analysis and modeling were developed for high redundancy systems. The study included a comprehensive data analysis of safety and relief valves at the Finnish and Swedish BWR plants, resulting in improved understanding of Common Cause Failure mechanisms in these components. The reference application on the Forsmark 1/2 reactor relief system, constituting of twelve safety/relief lines and two regulating relief lines, covered different safety criteria cases of reactor depressurization and overpressure protection function, and failure to re close sequences. For the quantification of dependencies, the Alpha Factor Model, the Binomial Probability Model and the Common Load Model were compared for applicability in high redundancy systems

  8. New Sunshine Program for Fiscal 2000. International cooperative project for developing photovoltaic power system practicalization technology (International Energy Agency (IEA)/Cooperative Program on Photovoltaic Power Systems (PVPS) implementing agreement - Task 1); 2000 nendo New sunshine keikaku. Taiyoko hatsuden system jitsuyoka gijustu kaihatsu kokusai kyoryoku jigyo (IEA taiyoko hatsuden system kenkyu kyoryoku program jisshi kyotei task 1)

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-03-01

    Fiscal 2000 participation in the above-named program is reported. At the Task 1 meeting of experts, electric power application in the participating countries was taken up and information was exchanged concerning the technical, economical, and environmental facets of photovoltaic power generation, efforts were made to disseminate the technology to non-participating countries, and coordination was established between the Tasks. For the preparation and publication of the ISR (International Survey Report), Japan would prepare and submit its NSR (National Survey Report) on Japan's photovoltaics-related policies, amounts of introduction and production, etc. The ISR was to be compiled by technical writers based on the NSRs submitted by the countries involved, to be bound into a book by September after supervision by the Task 1 staff and the executive committee. As for Market Implementation, it would be compiled under the leadership of Germany, Sweden, Denmark, Norway, and Japan. An added-value workshop was held at Glasgow, the United Kingdom, in May 2000 with the participation of 53 representing 14 countries. (NEDO)

  9. New Sunshine Program for Fiscal 2000. International cooperative project for developing photovoltaic power system practicalization technology (International Energy Agency (IEA)/Cooperative Program on Photovoltaic Power Systems (PVPS) implementing agreement - Task 1); 2000 nendo New sunshine keikaku. Taiyoko hatsuden system jitsuyoka gijustu kaihatsu kokusai kyoryoku jigyo (IEA taiyoko hatsuden system kenkyu kyoryoku program jisshi kyotei task 1)

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-03-01

    Fiscal 2000 participation in the above-named program is reported. At the Task 1 meeting of experts, electric power application in the participating countries was taken up and information was exchanged concerning the technical, economical, and environmental facets of photovoltaic power generation, efforts were made to disseminate the technology to non-participating countries, and coordination was established between the Tasks. For the preparation and publication of the ISR (International Survey Report), Japan would prepare and submit its NSR (National Survey Report) on Japan's photovoltaics-related policies, amounts of introduction and production, etc. The ISR was to be compiled by technical writers based on the NSRs submitted by the countries involved, to be bound into a book by September after supervision by the Task 1 staff and the executive committee. As for Market Implementation, it would be compiled under the leadership of Germany, Sweden, Denmark, Norway, and Japan. An added-value workshop was held at Glasgow, the United Kingdom, in May 2000 with the participation of 53 representing 14 countries. (NEDO)

  10. Reference handbook: Level detectors

    International Nuclear Information System (INIS)

    1990-01-01

    The purpose of this handbook is to provide Rocky Flats personnel with the information necessary to understand level measurement and detection. Upon completion of this handbook you should be able to do the following: List three reasons for measuring level. Describe the basic operating principles of the sight glass. Demonstrate proper techniques for reading a sight glass. Describe the basic operating principles of a float level detector. Describe the basic operating principles of a bubbler level indicating system. Explain the differences between a wet and dry reference leg indicating system, and describe how each functions. This handbook is designed for use by experienced Rocky Flats operators to reinforce and improve their current knowledge level, and by entry-level operators to ensure that they possess a minimum level of fundamental knowledge. Level Detectors is applicable to many job classifications and can be used as a reference for classroom work or for self-study. Although this reference handbook is by no means all-encompassing, you will gain enough information about this subject area to assist you in contributing to the safe operation of Rocky Flats Plant

  11. New reference trajectory optimization algorithm for a flight management system inspired in beam search

    Directory of Open Access Journals (Sweden)

    Alejandro MURRIETA-MENDOZA

    2017-08-01

    Full Text Available With the objective of reducing the flight cost and the amount of polluting emissions released in the atmosphere, a new optimization algorithm considering the climb, cruise and descent phases is presented for the reference vertical flight trajectory. The selection of the reference vertical navigation speeds and altitudes was solved as a discrete combinatory problem by means of a graph-tree passing through nodes using the beam search optimization technique. To achieve a compromise between the execution time and the algorithm’s ability to find the global optimal solution, a heuristic methodology introducing a parameter called “optimism coefficient was used in order to estimate the trajectory’s flight cost at every node. The optimal trajectory cost obtained with the developed algorithm was compared with the cost of the optimal trajectory provided by a commercial flight management system(FMS. The global optimal solution was validated against an exhaustive search algorithm(ESA, other than the proposed algorithm. The developed algorithm takes into account weather effects, step climbs during cruise and air traffic management constraints such as constant altitude segments, constant cruise Mach, and a pre-defined reference lateral navigation route. The aircraft fuel burn was computed using a numerical performance model which was created and validated using flight test experimental data.

  12. Design and realization of the high-precision weighing systems as the gravimetric references in PTB's national water flow standard

    International Nuclear Information System (INIS)

    Engel, Rainer; Beyer, Karlheinz; Baade, Hans-Joachim

    2012-01-01

    PTB's ‘Hydrodynamic Test Field’, which represents a high-accuracy water flow calibration facility, serves as the national primary standard for liquid flow measurands. As the core reference device of this flow facility, a gravimetric standard has been incorporated, which comprises three special-design weighing systems: 300 kg, 3 tons and 30 tons. These gravimetric references were realized as a combination of a strain-gauge-based and an electromagnetic-force-compensation load-cell-based balance, each. Special emphasis had to be placed upon the dynamics design of the whole weighing system, due to the high measurement resolution and the dynamic behavior of the weighing systems, which are dynamically affected by mechanical vibrations caused by environmental impacts, flow machinery operation, flow noise in the pipework and induced wave motions in the weigh tanks. Taking into account all the above boundary conditions, the design work for the gravimetric reference resulted in a concrete foundation ‘rock’ of some 300 tons that rests on a number of vibration isolators. In addition to these passively operating vibration isolators, the vibration damping effect is enhanced by applying an electronic level regulation device. (paper)

  13. Assessing the status of biological control as a management tool for suppression of invasive alien plants in South Africa

    OpenAIRE

    Zachariades, Costas; Paterson, Iain D.; Strathie, Lorraine W.; Hill, Martin P.; van Wilgen, Brian W.

    2017-01-01

    Background: Biological control of invasive alien plants (IAPs) using introduced natural enemies contributes significantly to sustained, cost-effective management of natural resources in South Africa. The status of, and prospects for, biological control is therefore integral to National Status Reports (NSRs) on Biological Invasions, the first of which is due in 2017. Objectives: Our aim was to evaluate the status of, and prospects for, biological control of IAPs in South Africa. We discuss...

  14. Zotero : a free and open-source reference manager

    DEFF Research Database (Denmark)

    Courraud, Julie

    2014-01-01

    Zotero is a free, open-source reference management program compatible with Linux®, Mac®, and Windows® operating systems. Libraries are backed up online allowing sharing between computers and even multiple users. Zotero makes it easy to keep your reference library organised and ‘clean’. Reference...

  15. A Software Reference Architecture for Service-Oriented 3D Geovisualization Systems

    Directory of Open Access Journals (Sweden)

    Dieter Hildebrandt

    2014-12-01

    Full Text Available Modern 3D geovisualization systems (3DGeoVSs are complex and evolving systems that are required to be adaptable and leverage distributed resources, including massive geodata. This article focuses on 3DGeoVSs built based on the principles of service-oriented architectures, standards and image-based representations (SSI to address practically relevant challenges and potentials. Such systems facilitate resource sharing and agile and efficient system construction and change in an interoperable manner, while exploiting images as efficient, decoupled and interoperable representations. The software architecture of a 3DGeoVS and its underlying visualization model have strong effects on the system’s quality attributes and support various system life cycle activities. This article contributes a software reference architecture (SRA for 3DGeoVSs based on SSI that can be used to design, describe and analyze concrete software architectures with the intended primary benefit of an increase in effectiveness and efficiency in such activities. The SRA integrates existing, proven technology and novel contributions in a unique manner. As the foundation for the SRA, we propose the generalized visualization pipeline model that generalizes and overcomes expressiveness limitations of the prevalent visualization pipeline model. To facilitate exploiting image-based representations (IReps, the SRA integrates approaches for the representation, provisioning and styling of and interaction with IReps. Five applications of the SRA provide proofs of concept for the general applicability and utility of the SRA. A qualitative evaluation indicates the overall suitability of the SRA, its applications and the general approach of building 3DGeoVSs based on SSI.

  16. A new method of 3-D cephalometry Part I: the anatomic Cartesian 3-D reference system.

    NARCIS (Netherlands)

    Swennen, G.R.J.; Schutyser, F.A.C.; Barth, E.L.; Groeve, P. De; Mey, A. De

    2006-01-01

    The purpose of this study was to present a new innovative three-dimensional (3-D) cephalometric method. Part I deals with the set-up and validation of a voxel-based semi-automatic 3-D cephalometric reference system. The CT data (DICOM 3.0 files) of 20 control patients with normal skeletal

  17. The Use of Reference Models in Business Process Renovation

    Directory of Open Access Journals (Sweden)

    Dejan Pajk

    2010-01-01

    Full Text Available Enterprise resource planning (ERP systems are often used by companies to automate and enhance their busi- ness processes. The capabilities of ERP systems can be described by best-practice reference models. The purpose of the article is to demonstrate the business process renovation approach with the use of reference models. Although the use of reference models brings many positive effects for business, they are still rarely used in Slovenian small and medium-sized compa- nies. The reasons for this may be found in the reference models themselves as well as in project implementation methodologies. In the article a reference model based on Microsoft Dynamics NAV is suggested. The reference model is designed using upgraded BPMN notation with additional business objects, which help to describe the models in more detail.

  18. A new birthweight reference in Guangzhou, southern China, and its comparison with the global reference.

    Science.gov (United States)

    He, Jian-Rong; Xia, Hui-Min; Liu, Yu; Xia, Xiao-Yan; Mo, Wei-Jian; Wang, Ping; Cheng, Kar Keung; Leung, Gabriel M; Feng, Qiong; Schooling, C Mary; Qiu, Xiu

    2014-12-01

    To formulate a new birthweight reference for different gestational ages in Guangzhou, southern China, and compare it with the currently used reference in China and the global reference. All singleton live births of more than 26 weeks' gestational age recorded in the Guangzhou Perinatal Health Care and Delivery Surveillance System for the years 2009, 2010 and 2011 (n=510 837) were retrospectively included in the study. In addition, the study sample was supplemented by all singleton live births (n=3538) at gestational ages 26-33 weeks from 2007 and 2008. We used Gaussian mixture models and robust regression to exclude outliers of birth weight and then applied Generalized Additive Models for Location, Scale, and Shape (GAMLSS) to generate smoothed percentile curves separately for gender and parity. Of infants defined as small for gestational age (SGA) in the new reference, 15.3-47.7% (depending on gestational age) were considered appropriate for gestational age (AGA) by the currently used reference of China. Of the infants defined as SGA by the new reference, 9.2% with gestational ages 34-36 weeks and 14.3% with 37-41 weeks were considered AGA by the global reference. At the 50th centile line, the new reference curve was similar to that of the global reference for gestational ages 26-33 weeks and above the global reference for 34-40 weeks. The new birthweight reference based on birthweight data for neonates in Guangzhou, China, differs from the reference currently used in China and the global reference, and appears to be more relevant to the local population. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  19. Python pocket reference, version 2.4

    CERN Document Server

    Lutz, Mark

    2005-01-01

    Python is optimized for quality, productivity, portability, and integration. Hundreds of thousands of Python developers around the world rely on Python for general-purpose tasks, Internet scripting, systems programming, user interfaces, and product customization. Available on all major computing platforms, including commercial versions of Unix, Linux, Windows, and Mac OS X, Python is portable, powerful and remarkable easy to use. With its convenient, quick-reference format, Python Pocket Reference, 3rd Edition is the perfect on-the-job reference. More importantly, it's now been refreshed

  20. Development of Power Controller System based on Model Reference Adaptive Control for a Nuclear Reactor

    International Nuclear Information System (INIS)

    Mohd Sabri Minhat; Izhar Abu Hussin; Ridzuan Abdul Mutalib

    2014-01-01

    The Reactor TRIGA PUSPATI (RTP)-type TRIGA Mark II was installed in the year 1982. The Power Controller System (PCS) or Automated Power Controller System (APCS) is very important for reactor operation and safety reasons. It is a function of controlled reactivity and reactor power. The existing power controller system is under development and due to slow response, low accuracy and low stability on reactor power control affecting the reactor safety. The nuclear reactor is a nonlinear system in nature, and it is power increases continuously with time. The reactor parameters vary as a function of power, fuel burnup and control rod worth. The output power value given by the power control system is not exactly as real value of reactor power. Therefore, controller system design is very important, an adaptive controller seems to be inevitable. The method chooses is a linear controller by using feedback linearization, for example Model Reference Adaptive Control. The developed APCS for RTP will be design by using Model Reference Adaptive Control (MRAC). The structured of RTP model to produce the dynamic behaviour of RTP on entire operating power range from 0 to 1MWatt. The dynamic behavior of RTP model is produced by coupling of neutronic and thermal-hydraulics. It will be developed by using software MATLAB/Simulink and hardware module card to handle analog input signal. A new algorithm for APCS is developed to control the movement of control rods with uniformity and orderly for RTP. Before APCS test to real plant, simulation results shall be obtained from RTP model on reactor power, reactivity, period, control rod positions, fuel and coolant temperatures. Those data are comparable with the real data for validation. After completing the RTP model, APCS will be tested to real plant on power control system performance by using real signal from RTP including fail-safe operation, system reliable, fast response, stability and accuracy. The new algorithm shall be a satisfied

  1. On Learning to Write Those **** References

    Science.gov (United States)

    Hartley, James

    2014-01-01

    In this article, the author discusses how difficult it is for psychology college students to learn to write multiple disciplines of references. It is hard for students to understand why all details have to be written in the right order and the right type-style--depending upon which reference system is used. In this article, the author proposes…

  2. Genetics Home Reference: systemic scleroderma

    Science.gov (United States)

    ... Facebook Twitter Home Health Conditions Systemic scleroderma Systemic scleroderma Printable PDF Open All Close All Enable Javascript to view the expand/collapse boxes. Description Systemic scleroderma is an autoimmune disorder that affects the skin ...

  3. Distributed Consensus Tracking for Second-Order Nonlinear Multiagent Systems with a Specified Reference State

    Directory of Open Access Journals (Sweden)

    Guoguang Wen

    2014-01-01

    Full Text Available This paper mainly addresses the distributed consensus tracking problem for second-order nonlinear multiagent systems with a specified reference trajectory. The dynamics of each follower consists of two terms: nonlinear inherent dynamics and a simple communication protocol relying only on the position and velocity information of its neighbors. The consensus reference is taken as a virtual leader, whose output is only its position and velocity information that is available to only a subset of a group of followers. To achieve consensus tracking, a class of nonsmooth control protocols is proposed which reply on the relative information among the neighboring agents. Then some corresponding sufficient conditions are derived. It is shown that if the communication graph associated with the virtual leader and followers is connected at each time instant, the consensus can be achieved at least globally exponentially with the proposed protocol. Rigorous proofs are given by using graph theory, matrix theory, and Lyapunov theory. Finally, numerical examples are presented to illustrate the theoretical analysis.

  4. Integrated Reliability and Risk Analysis System (IRRAS), Version 2.5: Reference manual

    International Nuclear Information System (INIS)

    Russell, K.D.; McKay, M.K.; Sattison, M.B.; Skinner, N.L.; Wood, S.T.; Rasmuson, D.M.

    1991-03-01

    The Integrated Reliability and Risk Analysis System (IRRAS) is a state-of-the-art, microcomputer-based probabilistic risk assessment (PRA) model development and analysis tool to address key nuclear plant safety issues. IRRAS is an integrated software tool that gives the user the ability to create and analyze fault trees and accident sequences using a microcomputer. This program provides functions that range from graphical fault tree construction to cut set generation and quantification. Version 1.0 of the IRRAS program was released in February of 1987. Since that time, many user comments and enhancements have been incorporated into the program providing a much more powerful and user-friendly system. This version has been designated IRRAS 2.5 and is the subject of this Reference Manual. Version 2.5 of IRRAS provides the same capabilities as Version 1.0 and adds a relational data base facility for managing the data, improved functionality, and improved algorithm performance. 7 refs., 348 figs

  5. Reference costs of electricity

    International Nuclear Information System (INIS)

    Terraz, N.

    1997-01-01

    The calculation of electric power production reference costs is used in France, even in the present case of over-capacity, for comparing the relative interest of the various means of power generation (nuclear plants, coal plants, hydroelectricity, gas combined cycles, etc.) and as an aid for future investment decisions. Reference costs show a sharp decrease between 1993 and 1997 due to advancements in nuclear plant operating ability and fossil fuel price decrease. Actuarial rates, plant service life, fuel costs and exchange rates are important parameters. The various costs from the research stage to the waste processing stages are discussed and the reference costs of the various power generation systems are presented and compared together with their competitiveness; the future of wind energy and cogeneration and the prospective of the renewal of nuclear plants at the 2010 horizon are also addressed

  6. Electroacoustical reference data

    CERN Document Server

    Eargle, John M

    2002-01-01

    The need for a general collection of electroacoustical reference and design data in graphical form has been felt by acousticians and engineers for some time. This type of data can otherwise only be found in a collection of handbooks. Therefore, it is the author's intention that this book serve as a single source for many electroacoustical reference and system design requirements. In form, the volume closely resembles Frank Massa's Acoustic Design Charts, a handy book dating from 1942 that has long been out of print. The basic format of Massa's book has been followed here: For each entry, graphical data are presented on the right page, while text, examples, and refer­ ences appear on the left page. In this manner, the user can solve a given problem without thumbing from one page to the next. All graphs and charts have been scaled for ease in data entry and reading. The book is divided into the following sections: A. General Acoustical Relationships. This section covers the behavior of sound transmis­ sion in...

  7. Application of an electronic bulletin board, as a mechanism of coordination of actions in complex systems - reference model

    Directory of Open Access Journals (Sweden)

    Katarzyna Grzybowska

    2015-06-01

    Full Text Available Background: In her previous research, the author of this publication indicates that coordination is a dependent variable which has a great driving force and is a very unstable factor. This results in the fact that all of the actions connected with coordination have an impact on other factors of cooperation as well as the integration of the enterprises in the structures of a supply chain type structure. Material and methods:  The article has been divided into two basic parts. The first part regards the reference models in complex systems (supply chain systems. They can constitute a starting point for the modelling of target processes in the built supply chain structure. The second part presents template process models (Reference Models for selected action coordination mechanisms during enterprise cooperation. The aim of the article is the presentation the model an Electronic Bulletin Board (EBB, as a mechanism of coordination of actions in complex systems. Results: The article was prepared on the basis of literature from the researched area. The material was also prepared on the basis of interviews with practitioners. They have allowed for the preparation of template process models (Reference Models for selected action coordination methods in the supply chain. Conclusions: The result of the work is a prepared model as well as its description in the use of IDEF0. The presented model is a demonstrative model. The proposed reference model makes it possible to define the parameters of a selected mechanism of coordination of actions, and forms a basis for affecting the progression of the process through an analysis of values of identified parameters. The parameterization of elements constitutes the foundation for the monitoring of the process via 1 unambiguous identification of the object of monitoring and 2 analysis of different variants of the progression of the process.

  8. Microfabricated Reference Electrodes and their Biosensing Applications

    Directory of Open Access Journals (Sweden)

    M. Jamal Deen

    2010-03-01

    Full Text Available Over the past two decades, there has been an increasing trend towards miniaturization of both biological and chemical sensors and their integration with miniaturized sample pre-processing and analysis systems. These miniaturized lab-on-chip devices have several functional advantages including low cost, their ability to analyze smaller samples, faster analysis time, suitability for automation, and increased reliability and repeatability. Electrical based sensing methods that transduce biological or chemical signals into the electrical domain are a dominant part of the lab-on-chip devices. A vital part of any electrochemical sensing system is the reference electrode, which is a probe that is capable of measuring the potential on the solution side of an electrochemical interface. Research on miniaturization of this crucial component and analysis of the parameters that affect its performance, stability and lifetime, is sparse. In this paper, we present the basic electrochemistry and thermodynamics of these reference electrodes and illustrate the uses of reference electrodes in electrochemical and biological measurements. Different electrochemical systems that are used as reference electrodes will be presented, and an overview of some contemporary advances in electrode miniaturization and their performance will be provided.

  9. A Service-Oriented E-Commerce Reference Architecture

    OpenAIRE

    Aulkemeier, Fabian; Schramm, Milan; Iacob, Maria Eugenia; van Hillegersberg, Jos

    2016-01-01

    Electronic commerce (e-commerce) is getting more and more important in people's every day shopping routines. Vendors who want to establish an online channel besides their traditional retail practice have to integrate the two supply chains. The underlying information technology systems should be able to support the integration of the new and old processes. While reference models are a popular means in designing this type of systems, the existing reference models in the field of e-commerce only...

  10. Roaming Reference: Reinvigorating Reference through Point of Need Service

    Directory of Open Access Journals (Sweden)

    Kealin M. McCabe

    2011-11-01

    Full Text Available Roaming reference service was pursued as a way to address declining reference statistics. The service was staffed by librarians armed with iPads over a period of six months during the 2010-2011 academic year. Transactional statistics were collected in relation to query type (Research, Facilitative or Technology, location and approach (librarian to patron, patron to librarian or via chat widget. Overall, roaming reference resulted in an additional 228 reference questions, 67% (n=153 of which were research related. Two iterations of the service were implemented, roaming reference as a standalone service (Fall 2010 and roaming reference integrated with traditional reference desk duties (Winter 2011. The results demonstrate that although the Weller Library’s reference transactions are declining annually, they are not disappearing. For a roaming reference service to succeed, it must be a standalone service provided in addition to traditional reference services. The integration of the two reference models (roaming reference and reference desk resulted in a 56% decline in the total number of roaming reference questions from the previous term. The simple act of roaming has the potential to reinvigorate reference services as a whole, forcing librarians outside their comfort zones, allowing them to reach patrons at their point of need.

  11. Histological and reference system for the analysis of mouse intervertebral disc.

    Science.gov (United States)

    Tam, Vivian; Chan, Wilson C W; Leung, Victor Y L; Cheah, Kathryn S E; Cheung, Kenneth M C; Sakai, Daisuke; McCann, Matthew R; Bedore, Jake; Séguin, Cheryle A; Chan, Danny

    2018-01-01

    A new scoring system based on histo-morphology of mouse intervertebral disc (IVD) was established to assess changes in different mouse models of IVD degeneration and repair. IVDs from mouse strains of different ages, transgenic mice, or models of artificially induced IVD degeneration were assessed. Morphological features consistently observed in normal, and early/later stages of degeneration were categorized into a scoring system focused on nucleus pulposus (NP) and annulus fibrosus (AF) changes. "Normal NP" exhibited a highly cellularized cell mass that decreased with natural ageing and in disc degeneration. "Normal AF" consisted of distinct concentric lamellar structures, which was disrupted in severe degeneration. NP/AF clefts indicated more severe changes. Consistent scores were obtained between experienced and new users. Altogether, our scoring system effectively differentiated IVD changes in various strains of wild-type and genetically modified mice and in induced models of IVD degeneration, and is applicable from the post-natal stage to the aged mouse. This scoring tool and reference resource addresses a pressing need in the field for studying IVD changes and cross-study comparisons in mice, and facilitates a means to normalize mouse IVD assessment between different laboratories. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 36:233-243, 2018. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  12. Digital Receiver Design for Transmitted Reference Ultra-Wideband Systems

    Directory of Open Access Journals (Sweden)

    Wang Yiyin

    2009-01-01

    Full Text Available Abstract A complete detection, channel estimation, synchronization, and equalization scheme for a transmitted reference (TR ultra-wideband (UWB system is proposed in this paper. The scheme is based on a data model which admits a moderate data rate and takes both the interframe interference (IFI and the intersymbol interference (ISI into consideration. Moreover, the bias caused by the interpulse interference (IPI in one frame is also taken into account. Based on the analysis of the stochastic properties of the received signals, several detectors are studied and evaluated. Furthermore, a data-aided two-stage synchronization strategy is proposed, which obtains sample-level timing in the range of one symbol at the first stage and then pursues symbol-level synchronization by looking for the header at the second stage. Three channel estimators are derived to achieve joint channel and timing estimates for the first stage, namely, the linear minimum mean square error (LMMSE estimator, the least squares (LS estimator, and the matched filter (MF. We check the performance of different combinations of channel estimation and equalization schemes and try to find the best combination, that is, the one providing a good tradeoff between complexity and performance.

  13. Digital Receiver Design for Transmitted Reference Ultra-Wideband Systems

    Directory of Open Access Journals (Sweden)

    Yiyin Wang

    2009-01-01

    Full Text Available A complete detection, channel estimation, synchronization, and equalization scheme for a transmitted reference (TR ultra-wideband (UWB system is proposed in this paper. The scheme is based on a data model which admits a moderate data rate and takes both the interframe interference (IFI and the intersymbol interference (ISI into consideration. Moreover, the bias caused by the interpulse interference (IPI in one frame is also taken into account. Based on the analysis of the stochastic properties of the received signals, several detectors are studied and evaluated. Furthermore, a data-aided two-stage synchronization strategy is proposed, which obtains sample-level timing in the range of one symbol at the first stage and then pursues symbol-level synchronization by looking for the header at the second stage. Three channel estimators are derived to achieve joint channel and timing estimates for the first stage, namely, the linear minimum mean square error (LMMSE estimator, the least squares (LS estimator, and the matched filter (MF. We check the performance of different combinations of channel estimation and equalization schemes and try to find the best combination, that is, the one providing a good tradeoff between complexity and performance.

  14. Reference spent fuel and its characteristics for the concept development of a deep geological disposal system

    Energy Technology Data Exchange (ETDEWEB)

    Kang, C. H.; Choi, J. W.; Ko, W. I.; Lee, Y. M.; Park, J. H.; Hwang, Y. S.; Kim, S. K.

    1997-09-01

    The total amount of spent fuel arisen from the nuclear power plant to be planned by 2010 at the basis of the long-term power development plan announced by MOTIE (Ministry of Trade, Industry and Energy Resource) in 1995 is estimated to derive the disposal capacity of a deep geological repository is derived. The reference spent fuel whose characteristics could be planned is selected by analysing the characteristic data such as initial enrichment, discharge burnup, geometry, dimension, gross weight, etc. Also isotopic concentration, radioactivity, decay heat, hazard index and radiation intensity of a reference spent fuel are quantitatively identified and summarized in order to apply in the concept developing works of a deep geological disposal system. (author). 12 refs., 24 tabs., 14 figs.

  15. Reference spent fuel and its characteristics for the concept development of a deep geological disposal system

    International Nuclear Information System (INIS)

    Kang, C. H.; Choi, J. W.; Ko, W. I.; Lee, Y. M.; Park, J. H.; Hwang, Y. S.; Kim, S. K.

    1997-09-01

    The total amount of spent fuel arisen from the nuclear power plant to be planned by 2010 at the basis of the long-term power development plan announced by MOTIE (Ministry of Trade, Industry and Energy Resource) in 1995 is estimated to derive the disposal capacity of a deep geological repository is derived. The reference spent fuel whose characteristics could be planned is selected by analysing the characteristic data such as initial enrichment, discharge burnup, geometry, dimension, gross weight, etc. Also isotopic concentration, radioactivity, decay heat, hazard index and radiation intensity of a reference spent fuel are quantitatively identified and summarized in order to apply in the concept developing works of a deep geological disposal system. (author). 12 refs., 24 tabs., 14 figs

  16. The disposal of Canada's nuclear fuel waste: comments on the postclosure assessment of a reference system

    International Nuclear Information System (INIS)

    Allan, C.J.; Goodwin, B.W.

    1996-07-01

    Canada, like other countries, is developing technology for disposal of its nuclear fuel waste , based on the concept of geological disposal in stable plutonic rock of the Canadian Shield. The choice of methods, materials, and designs for a disposal system will ultimately be made on the basis of safety, taking into account the characteristics of the specific site on which the facility is to be developed, costs and practicality. As part of its work in developing the technology for the disposal of Canada's nuclear fuel waste, AECL analyzed the performance of a hypothetical disposal facility that incorporates specific design choices for the engineered barriers and that assumes a specific geological setting. This system, comprising the disposal facility and the geological setting, and the results of the performance analysis, is described in an Environmental Impact Statement that AECL submitted in 1994 and in a Primary Reference for the EIS 'The Disposal of Canada's Nuclear Fuel Waste: Postclosure Assessment of a Reference System.' The performance analysis was not intended to be a general proof of the safety of disposal, but rather it presents a safety analysis of one specific system to illustrate the postclosure assessment methodology and to demonstrate that safety could be achieved for the system in question. Although the design of the disposal facility analyzed and the geological setting have specific features, the results obtained from the safety analysis can, however, be used to provide considerable insight into the performance of the various components that comprise the multibarrier geological disposal system. Moreover, the results can show how changes in the performance of specific components can affect the overall performance of the system. This report discusses these aspects of the postclosure analysis. (author)

  17. A Comparison Between the OSI Reference Model and the B-ISDN Protocol Reference Model

    DEFF Research Database (Denmark)

    Staalhagen, Lars

    1996-01-01

    This article aims at comparing the Open Systems Interconnection (OSI) Reference Model (RM) and the broadband integrated services digital network (B-ISDN) Protocol Reference Model (PRM). According to the International Telecommunications Union - Telecommunications Sector (ITU-T), the exact...... relationship between the lower layers of the OSI RM and the B-ISDN PRM is for further study. It is therefore the intention of this article to present some views on these relationships which hopefully could facilitate an interconnection between B-ISDN and data networks conforming to the OSI standards....

  18. Computer-assisted three-dimensional reconstruction of the corticospinal system as a reference for CT and MRI

    International Nuclear Information System (INIS)

    Buhmann, C.; Kretschmann, H.J.

    1998-01-01

    We present a three-dimensional (3D) anatomical computer-graphics model of the corticospinal system acquired from equidistant serial anatomical slices of six intracranially-fixed human brains. This model is part of a neuroanatomical reference system (NeuRef) which enables 3D visualization of the brain and shows the relationship of its components such as anatomical structures, functional fibre tracts and arteries. Sections through the models can be matched with corresponding CT or MR images. This allows the probable localisation of corticospinal fibres on CT or MRI. (orig.) (orig.)

  19. Decision support systems in nuclear emergencies: A scenario-based comparison of domestic and reference tools

    International Nuclear Information System (INIS)

    Vamanu, D.; Slavnicu, S. D.; Slavnicu, E.; Vamanu, B.

    2004-01-01

    The article reports selective results of a comparison between RODOS - an emerging decision support system for the management of nuclear emergencies in Europe developed by an international research consortium under EEC aegis, and a resident software package developed and maintained for similar purposes at IFIN-HH, Bucharest. Reproducible similarity patterns obtained in the output data distributions provide for simple normalising procedures that may ensure convergent radiological assessments. When properly consolidated on a sufficient scenario casuistry, such procedures could lend a certain resilience to domestic decision support tools over the interim lead time required by the full implementation of RODOS, or other major league, internationally accepted reference systems. (authors)

  20. Electrical engineer's reference book

    CERN Document Server

    Laughton, M A

    1985-01-01

    Electrical Engineer's Reference Book, Fourteenth Edition focuses on electrical engineering. The book first discusses units, mathematics, and physical quantities, including the international unit system, physical properties, and electricity. The text also looks at network and control systems analysis. The book examines materials used in electrical engineering. Topics include conducting materials, superconductors, silicon, insulating materials, electrical steels, and soft irons and relay steels. The text underscores electrical metrology and instrumentation, steam-generating plants, turbines

  1. Physics of Non-Inertial Reference Frames

    International Nuclear Information System (INIS)

    Kamalov, Timur F.

    2010-01-01

    Physics of non-inertial reference frames is a generalizing of Newton's laws to any reference frames. It is the system of general axioms for classical and quantum mechanics. The first, Kinematics Principle reads: the kinematic state of a body free of forces conserves and equal in absolute value to an invariant of the observer's reference frame. The second, Dynamics Principle extended Newton's second law to non-inertial reference frames and also contains additional variables there are higher derivatives of coordinates. Dynamics Principle reads: a force induces a change in the kinematic state of the body and is proportional to the rate of its change. It is mean that if the kinematic invariant of the reference frame is n-th derivative with respect the time, then the dynamics of a body being affected by the force F is described by the 2n-th differential equation. The third, Statics Principle reads: the sum of all forces acting a body at rest is equal to zero.

  2. Speed Estimation of Induction Motor Using Model Reference Adaptive System with Kalman Filter

    Directory of Open Access Journals (Sweden)

    Pavel Brandstetter

    2013-01-01

    Full Text Available The paper deals with a speed estimation of the induction motor using observer with Model Reference Adaptive System and Kalman Filter. For simulation, Hardware in Loop Simulation method is used. The first part of the paper includes the mathematical description of the observer for the speed estimation of the induction motor. The second part describes Kalman filter. The third part describes Hardware in Loop Simulation method and its realization using multifunction card MF 624. In the last section of the paper, simulation results are shown for different changes of the induction motor speed which confirm high dynamic properties of the induction motor drive with sensorless control.

  3. Analysis and comparison of NoSQL databases with an introduction to consistent references in big data storage systems

    Science.gov (United States)

    Dziedzic, Adam; Mulawka, Jan

    2014-11-01

    NoSQL is a new approach to data storage and manipulation. The aim of this paper is to gain more insight into NoSQL databases, as we are still in the early stages of understanding when to use them and how to use them in an appropriate way. In this submission descriptions of selected NoSQL databases are presented. Each of the databases is analysed with primary focus on its data model, data access, architecture and practical usage in real applications. Furthemore, the NoSQL databases are compared in fields of data references. The relational databases offer foreign keys, whereas NoSQL databases provide us with limited references. An intermediate model between graph theory and relational algebra which can address the problem should be created. Finally, the proposal of a new approach to the problem of inconsistent references in Big Data storage systems is introduced.

  4. Significant vestibular system impairment is common in a cohort of elderly patients referred for assessment of falls risk.

    Science.gov (United States)

    Jacobson, Gary P; McCaslin, Devin L; Grantham, Sarah L; Piker, Erin G

    2008-01-01

    Falls in elderly patients are associated with morbidity, mortality, and cost to the healthcare system. The development of falls risk assessment programs have represented a method of responding to what is known about injurious falls. The multidimensional assessments involve the comparison against normative data of a patient's performance on metrics known to influence the likelihood of future falls. The factors assessed usually include falls and medication history, measures of mentation, depression, orthostatic hypotension, simple or choice reaction time, gait stability, postural stability, and the integrity of the patient's vision, somesthetic, and vestibular senses. This investigation was conducted to measure the proportion of patients referred for falls risk assessment who have evidence of vestibular system impairment. Qualitative, retrospective review of data collected from 2003 to 2007. The cohort was 185 consecutive patients referred for multidimensional assessments of falls risk. Patients underwent quantitative assessments of peripheral and central vestibular system function consisting of electro- or videonystagmography (i.e., ENG/VNG), and sinusoidal harmonic acceleration testing. Results of these tests were compared to normative data. We found that 73% of the sample who underwent vestibular system assessment had quantitative evidence of either peripheral or central vestibular system impairment. Our results suggest that quantitative assessments of the vestibulo-ocular reflex should be conducted on patients who are evaluated for falls risk. These examinations should include at least caloric testing and, where available, rotational testing.

  5. Subject Reference Lists Produced by Computer

    Directory of Open Access Journals (Sweden)

    Ching-chih Chen

    1968-08-01

    Full Text Available A system developed to produce fourteen subject reference lists by IBM 360/75 is described in detail. The computerized system has many advantages over conventional manual procedures. The feedback from students and other users is discussed, and some analysis of cost is included.

  6. Computer-assisted three-dimensional reconstruction of the corticospinal system as a reference for CT and MRI

    Energy Technology Data Exchange (ETDEWEB)

    Buhmann, C. [Department of Neuroanatomy, Hannover Medical School (Germany)]|[University Hospital Eppendorf, Hamburg (Germany); Kretschmann, H.J. [Department of Neuroanatomy, Hannover Medical School (Germany)

    1998-09-01

    We present a three-dimensional (3D) anatomical computer-graphics model of the corticospinal system acquired from equidistant serial anatomical slices of six intracranially-fixed human brains. This model is part of a neuroanatomical reference system (NeuRef) which enables 3D visualization of the brain and shows the relationship of its components such as anatomical structures, functional fibre tracts and arteries. Sections through the models can be matched with corresponding CT or MR images. This allows the probable localisation of corticospinal fibres on CT or MRI. (orig.) (orig.) With 18 figs., 3 tabs., 40 refs.

  7. Reproducibility of the sella turcica landmark in three dimensions using a sella turcica-specific reference system

    International Nuclear Information System (INIS)

    Pittayapat, Pisha; Jacobs, Reinhilde; Odri, Guillaume A.; De Faria Vasconcelos, Karla; Willems, Guy; Olszewski, Raphael

    2015-01-01

    This study was performed to assess the reproducibility of identifying the sella turcica landmark in a three-dimensional (3D) model by using a new sella-specific landmark reference system. Thirty-two cone-beam computed tomographic scans (3D Accuitomo 170, J. Morita, Kyoto, Japan) were retrospectively collected. The 3D data were exported into the Digital Imaging and Communications in Medicine standard and then imported into the Maxilim software (Medicim NV, Sint-Niklaas, Belgium) to create 3D surface models. Five observers identified four osseous landmarks in order to create the reference frame and then identified two sella landmarks. The x, y, and z coordinates of each landmark were exported. The observations were repeated after four weeks. Statistical analysis was performed using the multiple paired t-test with Bonferroni correction (intraobserver precision: p<0.005, interobserver precision: p<0.0011). The intraobserver mean precision of all landmarks was <1 mm. Significant differences were found when comparing the intraobserver precision of each observer (p<0.005). For the sella landmarks, the intraobserver mean precision ranged from 0.43±0.34 mm to 0.51±0.46 mm. The intraobserver reproducibility was generally good. The overall interobserver mean precision was <1 mm. Significant differences between each pair of observers for all anatomical landmarks were found (p<0.0011). The interobserver reproducibility of sella landmarks was good, with >50% precision in locating the landmark within 1 mm. A newly developed reference system offers high precision and reproducibility for sella turcica identification in a 3D model without being based on two-dimensional images derived from 3D data.

  8. Reproducibility of the sella turcica landmark in three dimensions using a sella turcica-specific reference system

    Energy Technology Data Exchange (ETDEWEB)

    Pittayapat, Pisha; Jacobs, Reinhilde [University Hospitals Leuven, University of Leuven, Leuven (Belgium); Odri, Guillaume A. [Service de Chirurgie Orthopedique et Traumatologique, Centre Hospitalier Regional d' Orleans, Orleans Cedex2 (France); De Faria Vasconcelos, Karla [Dept. of Oral Diagnosis, Division of Oral Radiology, Piracicaba Dental School, University of Campinas, Sao Paulo (Brazil); Willems, Guy [Dept. of Oral Health Sciences, Orthodontics, KU Leuven and Dentistry, University Hospitals Leuven, University of Leuven, Leuven (Belgium); Olszewski, Raphael [Dept. of Oral and Maxillofacial Surgery, Cliniques Universitaires Saint Luc, Universite Catholique de Louvain, Brussels (Belgium)

    2015-03-15

    This study was performed to assess the reproducibility of identifying the sella turcica landmark in a three-dimensional (3D) model by using a new sella-specific landmark reference system. Thirty-two cone-beam computed tomographic scans (3D Accuitomo 170, J. Morita, Kyoto, Japan) were retrospectively collected. The 3D data were exported into the Digital Imaging and Communications in Medicine standard and then imported into the Maxilim software (Medicim NV, Sint-Niklaas, Belgium) to create 3D surface models. Five observers identified four osseous landmarks in order to create the reference frame and then identified two sella landmarks. The x, y, and z coordinates of each landmark were exported. The observations were repeated after four weeks. Statistical analysis was performed using the multiple paired t-test with Bonferroni correction (intraobserver precision: p<0.005, interobserver precision: p<0.0011). The intraobserver mean precision of all landmarks was <1 mm. Significant differences were found when comparing the intraobserver precision of each observer (p<0.005). For the sella landmarks, the intraobserver mean precision ranged from 0.43±0.34 mm to 0.51±0.46 mm. The intraobserver reproducibility was generally good. The overall interobserver mean precision was <1 mm. Significant differences between each pair of observers for all anatomical landmarks were found (p<0.0011). The interobserver reproducibility of sella landmarks was good, with >50% precision in locating the landmark within 1 mm. A newly developed reference system offers high precision and reproducibility for sella turcica identification in a 3D model without being based on two-dimensional images derived from 3D data.

  9. A system for environmental protection. Reference dose models for fauna and flora

    International Nuclear Information System (INIS)

    Pentreath, R.J.; Woodhead, D.S.

    2000-01-01

    Ideas have already been published on how the current problems relating to environmental protection could be explicitly addressed. One of the basic cornerstones of the proposed system is that of the use of reference dose models for fauna and flora, in a manner analogous to those used for the human species. The concept is that, for a number of both aquatic and terrestrial fauna and flora types, 'reference' dose models, and dose per unit (internal and external) exposure tables, could be compiled. These would then be used to draw broad conclusions on the likely effects for such organisms in relation to three broad environment end points of concern: life shortening; impairment of reproductive capacity; and scorable, cytogenetic damage. The level of complexity of the dose models needs to be commensurate with the morphological complexity of the modelled organism, its size, and the data bases which are either available or could be reasonably obtained. The most basic models considered are either solid ellipsoids or spheres, with fixed dimensions. Secondary models contain internal, but relatively simple geometric features representative of those key organs or tissues for which more precise estimates of dose are required. Their level of complexity is also a function of different internal and external sources of radiation, and expected differences in radiosensitivities. Tertiary models -of greater complexity- are only considered to be of value for higher vertebrates. The potential derivation and use of all three sets of models is briefly discussed. (author)

  10. An improved synchronous reference frame phase-locked loop for stand-alone variable speed constant frequency power generation systems

    DEFF Research Database (Denmark)

    Liu, Yi; Xu, Wei; Ke, Longzhang

    2017-01-01

    The phase-locked loop (PLL) based on conventional synchronous reference frame, i.e. dqPLL, is usually employed in grid-connected variable speed constant frequency (VSCF) power generation systems (PGSs). However, the voltage amplitude drop of stand-alone PGSs is often greater than that of the grid...

  11. PVWatts Version 1 Technical Reference

    Energy Technology Data Exchange (ETDEWEB)

    Dobos, A. P.

    2013-10-01

    The NREL PVWatts(TM) calculator is a web application developed by the National Renewable Energy Laboratory (NREL) that estimates the electricity production of a grid-connected photovoltaic system based on a few simple inputs. PVWatts combines a number of sub-models to predict overall system performance, and makes several hidden assumptions about performance parameters. This technical reference details the individual sub-models, documents assumptions and hidden parameters, and explains the sequence of calculations that yield the final system performance estimation.

  12. Sizewell 'B' PWR reference design

    International Nuclear Information System (INIS)

    1982-04-01

    The reference design for a PWR power station to be constructed as Sizewell 'B' is presented in 3 volumes containing 14 chapters and in a volume of drawings. The report describes the proposed design and provides the basis upon which the safety case and the Pre-Construction Safety Report have been prepared. The station is based on a 3425MWt Westinghouse PWR providing steam to two turbine generators each of 600 MW. The layout and many of the systems are based on the SNUPPS design for Callaway which has been chosen as the US reference plant for the project. (U.K.)

  13. Electronics engineer's reference book

    CERN Document Server

    Mazda, F F

    1989-01-01

    Electronics Engineer's Reference Book, Sixth Edition is a five-part book that begins with a synopsis of mathematical and electrical techniques used in the analysis of electronic systems. Part II covers physical phenomena, such as electricity, light, and radiation, often met with in electronic systems. Part III contains chapters on basic electronic components and materials, the building blocks of any electronic design. Part IV highlights electronic circuit design and instrumentation. The last part shows the application areas of electronics such as radar and computers.

  14. Prediction of Change in Prescription Ingredient Costs and Co-payment Rates under a Reference Pricing System in South Korea.

    Science.gov (United States)

    Heo, Ji Haeng; Rascati, Karen L; Lee, Eui-Kyung

    2017-05-01

    The reference pricing system (RPS) establishes reference prices within interchangeable reference groupings. For drugs priced higher than the reference point, patients pay the difference between the reference price and the total price. To predict potential changes in prescription ingredient costs and co-payment rates after implementation of an RPS in South Korea. Korean National Health Insurance claims data were used as a baseline to develop possible RPS models. Five components of a potential RPS policy were varied: reference groupings, reference pricing methods, co-pay reduction programs, manufacturer price reductions, and increased drug substitutions. The potential changes for prescription ingredient costs and co-payment rates were predicted for the various scenarios. It was predicted that transferring the difference (total price minus reference price) from the insurer to patients would reduce ingredient costs from 1.4% to 22.8% for the third-party payer (government), but patient co-payment rates would increase from a baseline of 20.4% to 22.0% using chemical groupings and to 25.0% using therapeutic groupings. Savings rates in prescription ingredient costs (government and patient combined) were predicted to range from 1.6% to 13.7% depending on various scenarios. Although the co-payment rate would increase, a 15% price reduction by manufacturers coupled with a substitution rate of 30% would result in a decrease in the co-payment amount (change in absolute dollars vs. change in rates). Our models predicted that the implementation of RPS in South Korea would lead to savings in ingredient costs for the third-party payer and co-payments for patients with potential scenarios. Copyright © 2017 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.

  15. Reference Device-Assisted Adaptive Location Fingerprinting

    Directory of Open Access Journals (Sweden)

    Dongjin Wu

    2016-06-01

    Full Text Available Location fingerprinting suffers in dynamic environments and needs recalibration from time to time to maintain system performance. This paper proposes an adaptive approach for location fingerprinting. Based on real-time received signal strength indicator (RSSI samples measured by a group of reference devices, the approach applies a modified Universal Kriging (UK interpolant to estimate adaptive temporal and environmental radio maps. The modified UK can take the spatial distribution characteristics of RSSI into account. In addition, the issue of device heterogeneity caused by multiple reference devices is further addressed. To compensate the measuring differences of heterogeneous reference devices, differential RSSI metric is employed. Extensive experiments were conducted in an indoor field and the results demonstrate that the proposed approach not only adapts to dynamic environments and the situation of changing APs’ positions, but it is also robust toward measuring differences of heterogeneous reference devices.

  16. Analysis of the Reference Systems of Modern Selenographic Systems

    Science.gov (United States)

    Nefedyev, Yuri; Petrova, Natalia; Andreev, Alexey; Demina, Natalya

    2016-07-01

    In this work analysis of the reference systems of modern selenographic systems was made. The center of the Moon's mass position relative to its center of figure was determined from the data of "Clementine" and "Kaguya" missions and "ULCN" and "KSC-1162" catalogues. The knowledge of the Moon's center of mass position relative to its center of figure is important for researches of the lunar origin, structure and evolution and in terms of precision solutions circumlunar navigation tasks. At the present this task is the most relevant and demanded for cosmic lunar missions.The expansions by spherical harmonics N=5 degree and order of the lunar function h (λ, β) using the package ASNI USTU were executed. Module of the expansion of the local area to surfaces to full sphere was used. The parameters of cosmic missions are given for comparison (SAI; Bills, Ferrari). The normalized coefficients from expansions for eight sources of hypsometric information are obtained: "Clementine" (N=40), "KSC-1162" (N=5), "Kiev" (N=5), "SAI" (N=10; Chuikova (1975)), "Bills, Ferrari", "Kaguya" (Selena, Japan mission), "ULCN" (The Unified Lunar Control Network 2005). The displacements of the lunar center of figure relative to the lunar center of the mass were defined from equations (Chuikova (1975)): Δ ξ = C_{11} √{3}, Δ η= S_{11} √{3}, Δ ζ = C_{10} √{3}, where ξ is the axis directed towards the Earth, η is equatorial axis directed perpendicularly to ξ , ζ is rotation axis of the Moon, C_{11} , S_{11} , C_{10} are the normalized amplitudes of the harmonics of the first order expansion of the relief. After that we considered: - mathematical models in the form of expansions in spherical functions - methods for estimating the model parameters; - information technology data processing. As a model describing the behavior of the relief on the lunar sphere is used the expansion of the height in a series of spherical harmonics (Sagitov (1979)) in the form of a regression model

  17. The Poisson alignment reference system implementation at the Advanced Photon Source

    International Nuclear Information System (INIS)

    Feier, I.

    1998-01-01

    The Poisson spot was established using a collimated laser beam from a 3-mW diode laser. It was monitored on a quadrant detector and found to be very sensitive to vibration and air disturbances. Therefore, for future work we strongly recommend a sealed vacuum tube in which the Poisson line may be propagated. A digital single-axis feedback system was employed to generate an straight line reference (SLR) on the X axis. Pointing accuracy was better than 8 ± 2 microns at a distance of 5 m. The digital system was found to be quite slow with a maximum bandwidth of 47 ± 9 Hz. Slow drifts were easily corrected but any vibration over 5 Hz was not. We recommend an analog proportional-integral-derivative (PID) controller for high bandwidth and smooth operation of the kinematic mirror. Although the Poisson alignment system (PAS) at the Advanced Photon Source is still in its infancy, it already shows great promise as a possible alignment system for the low-energy undulator test line (LEUTL). Since components such as wigglers and quadruples will initially be aligned with respect to each other using conventional means and mounted on some kind of rigid rail, the goal would be to align six to ten such rails over a distance of about 30 m. The PAS could be used to align these rails by mounting a sphere at the joint between two rails. These spheres would need to be in a vacuum pipe to eliminate the refractive effects of air. Each sphere would not be attached to either rail but instead to a flange connecting the vacuum pipes of each rail. Thus the whole line would be made up of straight, rigid segments that could be aligned by moving the joints. Each sphere would have its own detector, allowing the operators to actively monitor the position of each joint and therefore the overall alignment of the system

  18. Standardized Semantic Markup for Reference Terminologies, Thesauri and Coding Systems: Benefits for distributed E-Health Applications.

    Science.gov (United States)

    Hoelzer, Simon; Schweiger, Ralf K; Liu, Raymond; Rudolf, Dirk; Rieger, Joerg; Dudeck, Joachim

    2005-01-01

    With the introduction of the ICD-10 as the standard for diagnosis, the development of an electronic representation of its complete content, inherent semantics and coding rules is necessary. Our concept refers to current efforts of the CEN/TC 251 to establish a European standard for hierarchical classification systems in healthcare. We have developed an electronic representation of the ICD-10 with the extensible Markup Language (XML) that facilitates the integration in current information systems or coding software taking into account different languages and versions. In this context, XML offers a complete framework of related technologies and standard tools for processing that helps to develop interoperable applications.

  19. H.J. Bhabha: A case study of synchronous references

    International Nuclear Information System (INIS)

    Swarna, T.; Kalyane, V.L.; Prakasan, E.R.; Kumar, V.

    2006-01-01

    Quantitative analysis of the events of synchronous references in the research papers followed throughout the publishing career of an individual scientist revealed interesting highlights on the knowledge-generating-system. In the case study of Homi Jehangir Bhabha, the first quinquennium and fifth quinquennium of his research career had low self-references; the third quinquennium and the fourth quinquennium had moderate self-references; whereas the second quinquennium had the highest number of self-references. The two major clusters of self-references occurring during the second and third quinquenniums were indicators of active periods of knowledge-generating and faster communications. (author)

  20. Performance evaluation of the reference system for calibration of IPEN activities

    International Nuclear Information System (INIS)

    Martins, Elaine Wirney; Potiens, Maria da Penha A.

    2011-01-01

    The formation of good quality image in nuclear medicine services depends on several factors, including the radiopharmaceutical activity, which must be well determined by a specific apparatus, in perfect operating condition, called activimeter. Therefore, the establishment of a quality control program for measuring the radiopharmaceuticals radioactivity before being administered to the patient is crucial to the safe and effective use of the radiopharmaceuticals used in diagnostic and therapeutical procedures. Two activimeters, belonging by the Laboratorio de Calibracao do Instrumentos (LCI) of Instituto de Pesquisas Energeticas e Nucleares (IPEN), were evaluated: the secondary standard system NPL-CRC radionuclide calibrator, manufactured by Southern Scientific, and the work standard system CRC-15BT with traceability to National Institute of Standard and Technology (NIST). A set of standard sources of the radionuclides 1 '3 3 Ba, 57 Co and 137 Cs was used as reference to perform the quality control tests. The precision, accuracy and repeatability tests were in agreement with those established by the CNEN-NE 3.05 Brazilian standard, which recommends the variation limit of up to 10%, 5% and 5% respectively. The results obtained for the reproducibility tests presented a variation always below 1,5%, which means it is within the IEC 61674 international standard recommendation of up to 3%. Activimeters response regarding linearity showed concordance between the measured activities and the theoretical curve for both activimeters. (author)

  1. A Functional Reference Architecture for Aggregators

    DEFF Research Database (Denmark)

    Bondy, Daniel Esteban Morales; Heussen, Kai; Gehrke, Oliver

    2015-01-01

    Aggregators are considered to be a key enabling technology for harvesting power system services from distributed energy resources (DER). As a precondition for more widespread use of aggregators in power systems, methods for comparing and validating aggregator designs must be established. This paper...... proposes a functional reference architecture for aggregators to address this requirement....

  2. On the system of provision of ojsc "MMC 'Norilsk Nickel'" with interstate and State certified reference materials for quality control of cobalt, nickel, copper and promproducts

    Directory of Open Access Journals (Sweden)

    T. V. Shabelnikova

    2014-01-01

    Full Text Available In order to manage the quality of OJSC "MMC "Norilsk Nickel" products the Centre of Certified Reference Material Development has developed and is currently successfully implementing a system of operations provision with interstate and state certified reference materials of nickel, cobalt and copper composition. The system wholly corresponds to modern metrological requirements. The Centre of Reference Materials Development, fulfilling leading function in the field of state certified reference material production and supply to the Company's operations, aims its activity both at the development of new types of certified reference materials in the form of metals and at widening the range of synthetic oxide certified reference materials. Developed for the first time, metallic state certified reference materials of nickel, cobalt composition with certified mass fractions of oxygen, hydrogen, nitrogen, sulfur and carbon were put into practice of the Company's analytical services work. Certified reference material use provides the possibility to take into account requirements of some consumers to the quality of nickel and produce by OJSC "MMC "Norilsk Nickel" and also helps to raise competitive ability of the products on the world metals market. Over recent years the Centre fulfilled the work on the development, certification in established order, approval and entering into the State Register twenty five types of state certified reference materials. Certified reference materials are intended for fulfillment of the analysis of chemical composition of nickel, cobalt and copper in terms of their conformity with both national and international standards.

  3. The derivation of the general form of kinematics with the universal reference system

    Directory of Open Access Journals (Sweden)

    Karol Szostek

    2018-03-01

    Full Text Available In the article, the whole class of time and position transformations was derived. These transformations were derived based on the analysis of the Michelson-Morley experiment and its improved version, that is the Kennedy-Thorndike experiment. It is possible to derive a different kinematics of bodies based on each of these transformations. In this way, we demonstrated that the Special Theory of Relativity is not the only theory explaining the results of experiments with light. There is the whole continuum of the theories of kinematics of bodies which correctly explain the Michelson-Morley experiment and other experiments in which the velocity of light is measured. Based on the derived transformations, we derive the general formula for the velocity of light in vacuum measured in any inertial reference system. We explain why the Michelson-Morley and Kennedy-Thorndike experiments could not detect the ether. We present and discuss three examples of specific transformations. Finally, we explain the phenomenon of anisotropy of the cosmic microwave background radiation by means of the presented theory. The theory derived in this work is called the Special Theory of Ether – with any transverse contraction. The entire article contains only original research conducted by its authors. Keywords: Kinematics of bodies, Universal frame of reference, Transformation of time and position, One-way speed of light, Anisotropy of cosmic microwave background

  4. An Attitude Heading and Reference System For Marine Satellite Tracking Antenna

    DEFF Research Database (Denmark)

    Wang, Yunlong; Soltani, Mohsen; Hussain, Dil muhammed Akbar

    2017-01-01

    One of the most challenging problems for marine satellite tracking antennas (MSTAs) is to estimate the antenna attitude, which is affected by the ship motion, especially the ship vibration and rotational motions caused by ocean waves. To overcome this problem, an attitude heading and reference...... conditions, an attitude estimator based on virtual horizontal reference is introduced for situations of accelerometer malfunction, where the ship is suffering from wave shocks in high sea states. The performance of the designed AHRS for MSTA is assessed through hardware experiments using a Stewart platform...

  5. Nuclear Structure References (NSR) file

    International Nuclear Information System (INIS)

    Ewbank, W.B.

    1978-08-01

    The use of the Nuclear Structure References file by the Nuclear Data Project at ORNL is described. Much of the report concerns format information of interest only to those preparing input to the system or otherwise needing detailed knowledge of its internal structure. 17 figures

  6. The economic value of one ton CO2: what system of reference for public action?

    International Nuclear Information System (INIS)

    2007-04-01

    Given the convergence of scientific analyses of global warming and its consequences for the planet - evaluated for years by the Intergovernmental Panel on Climate Change (IPCC) - it is no longer possible to postpone the efforts required to reduce our emissions of greenhouse gases substantially. However, the choice of actions to take and the calendar of priorities are proving complex to define: the social and economic consequences are great, and neither France (which represents 2% of global emissions) nor Europe (15%) are up to treating the problem independently of the rest of the world. Faced with this challenge, and with budgetary constraints imposing a rationalisation of expenditure, public action must have measuring instruments at its disposal: the value of one ton of carbon is one such instrument. This Strategic Newswatch has a twofold objective: to recall the usefulness of this reference value which, though it cannot guarantee the validity of different public policies, may contribute to ensuring their consistency; and to present the different approaches and difficulties that producing such a reference system introduces. (author)

  7. Single and multispecies reference points for Baltic fish stocks

    DEFF Research Database (Denmark)

    Gislason, Henrik

    1999-01-01

    reference points. Management advice based on biomass reference points will also differ. In the single species situation the combinations of cod and pelagic fishing effort for which the equilibrium spawning- stock biomass of the three species is above the biomass reference points forms a rectangular area......Single and multispecies models are used to examine the effect of species interaction on biological reference points for cod, herring, and sprat in the Baltic. The results demonstrate that reference points are different in single and multispecies contexts. Reference points for fishing mortality...... based on single-species yield and SSB calculations are difficult to use when natural mortality depends on the absolute abundance of the predators and their alternative prey. Reference points based on maximizing total yield from the system may lead to impractical results when species interact...

  8. Genetics Home Reference: systemic lupus erythematosus

    Science.gov (United States)

    ... Twitter Home Health Conditions Systemic lupus erythematosus Systemic lupus erythematosus Printable PDF Open All Close All Enable Javascript to view the expand/collapse boxes. Description Systemic lupus erythematosus (SLE) is a chronic disease that causes inflammation ...

  9. Assessment of a dynamic reference material for calibration of full-field measurement systems

    Science.gov (United States)

    Hack, Erwin; Feligiotti, Mara; Davighi, Andrea; Whelan, Maurice; Wang, Weizhuo V.; Patterson, Eann A.

    2012-10-01

    For holography and speckle interferometry the calibration of the sensitivity is a must, because illumination and observation directions vary across the field of view. A numerical estimate or a static calibration using rigid body motions is standard, and reference materials exist for static strain calibration. Recently, reference materials for the dynamic calibration of optical instruments of displacement and strain measurement were designed and prototypes were manufactured in the European FP7 project ADVISE. We review the properties of the reference material and the concept of traceability for the field of displacement values by using a calibrated single point transducer. The mode shape is assessed using out-of-plane DSPI, Finite Element Analysis as well as analytic solutions of the plate vibration. We present measurements using stroboscopic DSPI on the reference material under acoustic excitation and compare the measured mode shapes to the ones predicted by FE analysis. We apply different comparison methodologies based on point-by-point deviations and on decomposition of the mode shapes into a set of orthogonal basis functions. The latter method is well suited to assess stability and reproducibility of a mode shape. Finally, the deviations are used to estimate the reference material uncertainty which is an essential parameter for determining the calibration uncertainty. Uncertainty contributions of the DSPI set-up are taken into account. To conclude, the application area and limitations of the reference material are discussed.

  10. Anthology of the renin-angiotensin system: a one hundred reference approach to angiotensin II antagonists.

    Science.gov (United States)

    Ménard, J

    1993-04-01

    To provide a historical overview of the renin-angiotensin system as a guide to the introduction of a new therapeutic pathway, non-peptide inhibition of a angiotensin II. One hundred references were selected as a personal preference, for their originality or for their potential impact on medicine. This review raises the following questions for future research. (1) Will the long-term cardiovascular effects of angiotensin converting enzyme (ACE) inhibition, angiotensin II antagonism and renin inhibition be similar or not, and dependent or independent of blood pressure levels? (2) What are the local-regional interactions between vasoconstrictor and vasodilator systems, and does the renin-angiotensin system synchronize these regional hemodynamic regulatory mechanisms? (3) If hypertension is the result of an interaction between genetic and environmental factors, do proteins secreted through constitutive pathways contribute to the genetic abnormality (prorenin, angiotensinogen, ACE) while regulated secretion (renin) and other regulatory mechanisms (angiotensin II receptors) provide biological support for the environmental effects?

  11. Growth references

    NARCIS (Netherlands)

    Buuren, S. van

    2007-01-01

    A growth reference describes the variation of an anthropometric measurement within a group of individuals. A reference is a tool for grouping and analyzing data and provides a common basis for comparing populations.1 A well known type of reference is the age-conditional growth diagram. The

  12. Online Reference Service--How to Begin: A Selected Bibliography.

    Science.gov (United States)

    Shroder, Emelie J., Ed.

    1982-01-01

    Materials in this bibliography were selected and recommended by members of the Use of Machine-Assisted Reference in Public Libraries Committee, Reference and Adult Services Division, American Library Association. Topics include: financial aspects, equipment and communications considerations, comparing databases and database systems, advertising…

  13. Establishing a Business Process Reference Model for Universities

    KAUST Repository

    Svensson, Carsten

    2012-09-01

    Modern universities are by any standard complex organizations that, from an IT perspective, present a number of unique challenges. This paper will propose establishing a business process reference framework. The benefit to the users would be a better understanding of the system landscape, business process enablement, collection of performance data and systematic reuse of existing community experience and knowledge. For these reasons reference models such as the SCOR (Supply Chain Operations Reference), DCOR (Design Chain Operations Reference) and ITIL (Information Technology Infrastructure Library) have gained popularity among organizations in both the private and public sectors. We speculate that this success can be replicated in a university setting. Furthermore the paper will outline how the research group suggests moving ahead with the research which will lead to a reference model.

  14. Computerized literature reference system: use of an optical scanner and optical character recognition software.

    Science.gov (United States)

    Lossef, S V; Schwartz, L H

    1990-09-01

    A computerized reference system for radiology journal articles was developed by using an IBM-compatible personal computer with a hand-held optical scanner and optical character recognition software. This allows direct entry of scanned text from printed material into word processing or data-base files. Additionally, line diagrams and photographs of radiographs can be incorporated into these files. A text search and retrieval software program enables rapid searching for keywords in scanned documents. The hand scanner and software programs are commercially available, relatively inexpensive, and easily used. This permits construction of a personalized radiology literature file of readily accessible text and images requiring minimal typing or keystroke entry.

  15. Prescribing during pregnancy and lactation with reference to the Swedish classification system - A population-based study among Danish women

    NARCIS (Netherlands)

    Olesen, C; Sorensen, HT; de Jong-van den Berg, L; Olsen, J; Steffensen, FH

    Aim. To assess the current prescribing pattern for 15,756 primiparae before, during, and after their pregnancies with reference to fetal and neonatal risk. Method. A prescription database study with linkage to The Danish Medical Birth Registry from 1991 to 1996. The drug subsidy system in Danish

  16. Reference-shaping adaptive control by using gradient descent optimizers.

    Directory of Open Access Journals (Sweden)

    Baris Baykant Alagoz

    Full Text Available This study presents a model reference adaptive control scheme based on reference-shaping approach. The proposed adaptive control structure includes two optimizer processes that perform gradient descent optimization. The first process is the control optimizer that generates appropriate control signal for tracking of the controlled system output to a reference model output. The second process is the adaptation optimizer that performs for estimation of a time-varying adaptation gain, and it contributes to improvement of control signal generation. Numerical update equations derived for adaptation gain and control signal perform gradient descent optimization in order to decrease the model mismatch errors. To reduce noise sensitivity of the system, a dead zone rule is applied to the adaptation process. Simulation examples show the performance of the proposed Reference-Shaping Adaptive Control (RSAC method for several test scenarios. An experimental study demonstrates application of method for rotor control.

  17. Connecting VLBI and Gaia celestial reference frames

    Directory of Open Access Journals (Sweden)

    Zinovy Malkin

    2016-09-01

    Full Text Available The current state of the link problem between radio and optical celestial reference frames is considered.The main objectives of the investigations in this direction during the next few years are the preparation of a comparisonand the mutual orientation and rotation between the optical it Gaia Celestial Reference Frame (GCRFand the 3rd generation radio International Celestial Reference Frame (ICRF3, obtained from VLBI observations.Both systems, ideally, should be a realization of the ICRS (International Celestial Reference System at micro-arcsecond level accuracy.Therefore, the link accuracy between the ICRF and GCRF should be obtained with similar error level, which is not a trivial taskdue to relatively large systematic and random errors in source positions at different frequency bands.In this paper, a brief overview of recent work on the GCRF--ICRF link is presented.Additional possibilities to improve the GCRF--ICRF link accuracy are discussed.The suggestion is made to use astrometric radio sources with optical magnitude to 20$^m$ rather than to 18$^m$ as currently plannedfor the GCRF--ICRF link.In addition, the use of radio stars is also a prospective method to obtain independent and accurate orientation between the Gaia frame and the ICRF.

  18. Connecting VLBI and Gaia Celestial Reference Frames

    Energy Technology Data Exchange (ETDEWEB)

    Malkin, Zinovy, E-mail: malkin@gao.spb.ru [Department of Radio Astronomy Research, The Pulkovo Astronomical Observatory, St. Petersburg (Russian Federation); Institute of Earth Sciences, St. Petersburg State University, St. Petersburg (Russian Federation); Astronomy and Cosmic Geodesy Department, Kazan Federal University, Kazan (Russian Federation)

    2016-09-12

    The current state of the link problem between radio and optical celestial reference frames is considered. The main objectives of the investigations in this direction during the next few years are the preparation of a comparison and the mutual orientation and rotation between the optical Gaia Celestial Reference Frame (GCRF) and the 3rd generation radio International Celestial Reference Frame (ICRF3), obtained from VLBI observations. Both systems, ideally, should be a realization of the ICRS (International Celestial Reference System) at micro-arcsecond level accuracy. Therefore, the link accuracy between the ICRF and GCRF should be obtained with similar error level, which is not a trivial task due to relatively large systematic and random errors in source positions at different frequency bands. In this paper, a brief overview of recent work on the GCRF–ICRF link is presented. Additional possibilities to improve the GCRF–ICRF link accuracy are discussed. The suggestion is made to use astrometric radio sources with optical magnitude to 20{sup m} rather than to 18{sup m} as currently planned for the GCRF–ICRF link. In addition, the use of radio stars is also a prospective method to obtain independent and accurate orientation between the Gaia frame and the ICRF.

  19. Reference pricing system and competition: case study from Portugal.

    Science.gov (United States)

    Portela, Conceiçăo

    2009-10-01

    To characterize the patterns of competition for a sample of drugs in the Portuguese pharmaceutical market before (January 2002-March 2003) and after (April 2003-June 2003) the introduction of the reference pricing system (RPS). We performed a descriptive, retrospective, longitudinal analysis, with monthly observations from January 2002 until June 2003 of 15 homogeneous groups. The groups represented the upper limit of public pharmaceutical expenditure in the RPS segment in 2003 (n=270). Measures of competition were: 1) number of presentations; 2) prescriptions' concentration in the generic and originator (brand) segments, using Herfindahl-Hirschman Index (HHI); and 3) dominant positions of market leader in the homogeneous group. A correlation analysis between the number of presentations, the HHI, and the dominant position of the market leader was performed using Pearson coefficient of correlation. The structure of the market changed with the introduction of RPS. We found an increasing number of generic presentations (from 4+/-3 to 7+/-4; mean+/-standard deviation) and a decrease in the HHI for the generics market segment (from 0.7+/-0.2 to 0.6+/-0.3). There was a negative correlation between those variables that increased after the introduction of RPS (from -0.6 to -0.8). The HHI for brands and the dominant positions remained unchanged. After the implementation of RPS, the increased competition was mainly driven by economic and social agents in the generics market segment but not in the brands market segment.

  20. A Modernized National Spatial Reference System in 2022: Focus on the Caribbean Terrestrial Reference Frame

    Science.gov (United States)

    Roman, D. R.

    2017-12-01

    In 2022, the National Geodetic Survey will replace all three NAD 83 reference frames the four new terrestrial reference frames. Each frame will be named after a tectonic plate (North American, Pacific, Caribbean and Mariana) and each will be related to the IGS frame through three Euler Pole parameters (EPPs). This talk will focus on practical application in the Caribbean region. A working group is being re-established for development of the North American region and will likely also result in analysis of the Pacific region as well. Both of these regions are adequately covered with existing CORS sites to model the EPPs. The Mariana region currently lacks sufficient coverage, but a separate project is underway to collect additional information to help in defining EPPs for that region at a later date. The Caribbean region has existing robust coverage through UNAVCO's COCONet and other data sets, but these require further analysis. This discussion will focus on practical examination of Caribbean sites to establish candidates for determining the Caribbean frame EPPs as well as an examination of any remaining velocities that might inform a model of the remaining velocities within that frame (Intra-Frame Velocity Model). NGS has a vested interest in defining such a model to meet obligations to U.S. citizens in Puerto Rico and the U.S. Virgin Islands. Beyond this, NGS aims to collaborate with other countries in the region through efforts with SIRGAS and UN-GGIM-Americas for a more acceptable regional model to serve everyone's needs.

  1. EARS: Electronic Access to Reference Service.

    Science.gov (United States)

    Weise, F O; Borgendale, M

    1986-10-01

    Electronic Access to Reference Service (EARS) is a front end to the Health Sciences Library's electronic mail system, with links to the online public catalog. EARS, which became operational in September 1984, is accessed by users at remote sites with either a terminal or microcomputer. It is menu-driven, allowing users to request: a computerized literature search, reference information, a photocopy of a journal article, or a book. This paper traces the history of EARS and discusses its use, its impact on library staff and services, and factors that influence the diffusion of new technology.

  2. Reference materials and representative test materials: the nanotechnology case

    International Nuclear Information System (INIS)

    Roebben, G.; Rasmussen, K.; Kestens, V.; Linsinger, T. P. J.; Rauscher, H.; Emons, H.; Stamm, H.

    2013-01-01

    An increasing number of chemical, physical and biological tests are performed on manufactured nanomaterials for scientific and regulatory purposes. Existing test guidelines and measurement methods are not always directly applicable to or relevant for nanomaterials. Therefore, it is necessary to verify the use of the existing methods with nanomaterials, thereby identifying where modifications are needed, and where new methods need to be developed and validated. Efforts for verification, development and validation of methods as well as quality assurance of (routine) test results significantly benefit from the availability of suitable test and reference materials. This paper provides an overview of the existing types of reference materials and introduces a new class of test materials for which the term ‘representative test material’ is proposed. The three generic concepts of certified reference material, reference material(non-certified) and representative test material constitute a comprehensive system of benchmarks that can be used by all measurement and testing communities, regardless of their specific discipline. This paper illustrates this system with examples from the field of nanomaterials, including reference materials and representative test materials developed at the European Commission’s Joint Research Centre, in particular at the Institute for Reference Materials and Measurements (IRMM), and at the Institute for Health and Consumer Protection (IHCP).

  3. Systems Analysis Programs for Hands-on Integrated Reliability Evaluations (SAPHIRE), Version 5.0: Integrated Reliability and Risk Analysis System (IRRAS) reference manual. Volume 2

    International Nuclear Information System (INIS)

    Russell, K.D.; Kvarfordt, K.J.; Skinner, N.L.; Wood, S.T.; Rasmuson, D.M.

    1994-07-01

    The Systems Analysis Programs for Hands-on Integrated Reliability Evaluations (SAPHIRE) refers to a set of several microcomputer programs that were developed to create and analyze probabilistic risk assessments (PRAs), primarily for nuclear power plants. The Integrated Reliability and Risk Analysis System (IRRAS) is a state-of-the-art, microcomputer-based probabilistic risk assessment (PRA) model development and analysis tool to address key nuclear plant safety issues. IRRAS is an integrated software tool that gives the use the ability to create and analyze fault trees and accident sequences using a microcomputer. This program provides functions that range from graphical fault tree construction to cut set generation and quantification to report generation. Version 1.0 of the IRRAS program was released in February of 1987. Since then, many user comments and enhancements have been incorporated into the program providing a much more powerful and user-friendly system. This version has been designated IRRAS 5.0 and is the subject of this Reference Manual. Version 5.0 of IRRAS provides the same capabilities as earlier versions and ads the ability to perform location transformations, seismic analysis, and provides enhancements to the user interface as well as improved algorithm performance. Additionally, version 5.0 contains new alphanumeric fault tree and event used for event tree rules, recovery rules, and end state partitioning

  4. Performance evaluation of the reference system for calibration of IPEN activities

    Energy Technology Data Exchange (ETDEWEB)

    Martins, Elaine Wirney; Potiens, Maria da Penha A., E-mail: ewmartins@ipen.br, E-mail: mppalbu@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2011-07-01

    The formation of good quality image in nuclear medicine services depends on several factors, including the radiopharmaceutical activity, which must be well determined by a specific apparatus, in perfect operating condition, called activimeter. Therefore, the establishment of a quality control program for measuring the radiopharmaceuticals radioactivity before being administered to the patient is crucial to the safe and effective use of the radiopharmaceuticals used in diagnostic and therapeutical procedures. Two activimeters, belonging by the Laboratorio de Calibracao do Instrumentos (LCI) of Instituto de Pesquisas Energeticas e Nucleares (IPEN), were evaluated: the secondary standard system NPL-CRC radionuclide calibrator, manufactured by Southern Scientific, and the work standard system CRC-15BT with traceability to National Institute of Standard and Technology (NIST). A set of standard sources of the radionuclides {sup 1}'3{sup 3}Ba, {sup 57}Co and {sup 137}Cs was used as reference to perform the quality control tests. The precision, accuracy and repeatability tests were in agreement with those established by the CNEN-NE 3.05 Brazilian standard, which recommends the variation limit of up to 10%, 5% and 5% respectively. The results obtained for the reproducibility tests presented a variation always below 1,5%, which means it is within the IEC 61674 international standard recommendation of up to 3%. Activimeters response regarding linearity showed concordance between the measured activities and the theoretical curve for both activimeters. (author)

  5. Recent references

    International Nuclear Information System (INIS)

    Ramavataram, S.

    1991-01-01

    In support of a continuing program of systematic evaluation of nuclear structure data, the National Nuclear Data Center maintains a complete computer file of references to the nuclear physics literature. Each reference is tagged by a keyword string, which indicates the kinds of data contained in the article. This master file of Nuclear Structure References (NSR) contains complete keyword indexes to literature published since 1969, with partial indexing of older references. Any reader who finds errors in the keyword descriptions is urged to report them to the National Nuclear Data Center so that the master NSR file can be corrected. In 1966, the first collection of Recent References was published as a separate issue of Nuclear Data Sheets. Every four months since 1970, a similar indexed bibliography to new nuclear experiments has been prepared from additions to the NSR file and published. Beginning in 1978, Recent References was cumulated annually, with the third issue completely superseding the two issues previously published during a given year. Due to publication policy changes, cumulation of Recent Reference was discontinued in 1986. The volume and issue number of all the cumulative issues published to date are given. NNDC will continue to respond to individual requests for special bibliographies on nuclear physics topics, in addition to those easily obtained from Recent References. If the required information is available from the keyword string, a reference list can be prepared automatically from the computer files. This service can be provided on request, in exchange for the timely communication of new nuclear physics results (e.g., preprints). A current copy of the NSR file may also be obtained in a standard format on magnetic tape from NNDC. Requests for special searches of the NSR file may also be directed to the National Nuclear Data Center

  6. The role of certified reference materials in material control and accounting

    International Nuclear Information System (INIS)

    Turel, S.P.

    1979-01-01

    One way of providing an adequate material control and accounting system for the nuclear fuel cycle is to calculate material unaccounted for (MUF) after a physical inventory and to compare the limit of error of the MUF value (LEMUF) against prescribed criteria. To achieve a meaningful LEMUF, a programme for the continuing determination of systematic and random errors is necessary. Within this programme it is necessary to achieve traceability of all Special Nuclear Material (SNM) control and accounting measurements to an International/National Measurement System by means of Certified Reference Materials. SNM measurements for control and accounting are made internationally on a great variety of materials using many diverse measurement procedures by a large number of facilities. To achieve valid overall accountability over this great variety of measurements there must be some means of relating all these measurements and their uncertainties to each other. This is best achieved by an International/National Measurement System (IMS/NMS). To this end, all individual measurement systems must be compatible to the IMS/NMS and all measurement results must be traceable to appropriate international/national Primary Certified Reference Materials. To obtain this necessary compatibility for any given SNM measurement system, secondary certified reference materials or working reference materials are needed for every class of SNM and each type of measurement system. Ways to achieve ''traceability'' and the various types of certified reference material are defined and discussed in this paper. (author)

  7. Model Predictive Control for Offset-Free Reference Tracking

    Czech Academy of Sciences Publication Activity Database

    Belda, Květoslav

    2016-01-01

    Roč. 5, č. 1 (2016), s. 8-13 ISSN 1805-3386 Institutional support: RVO:67985556 Keywords : offset-free reference tracking * predictive control * ARX model * state-space model * multi-input multi-output system * robotic system * mechatronic system Subject RIV: BC - Control Systems Theory http://library.utia.cas.cz/separaty/2016/AS/belda-0458355.pdf

  8. A survey of reference electrodes for high temperature waters

    International Nuclear Information System (INIS)

    Molander, A.; Eriksson, Sture; Pein, K.

    2000-11-01

    In nuclear power plants, corrosion potential measurements are used to follow the conditions for different corrosion types in reactor systems, particularly IGSCC in BWRs. The goal of this work has been to give a survey of reference electrodes for high temperature water, both those that are used for nuclear environments and those that are judged to possible future development. The reference electrodes that are used today in nuclear power plants for corrosion potential measurements are of three types. Silver chloride electrodes, membrane electrodes and platinum electrodes (hydrogen electrodes). The principals for their function is described as well as the conversion of measured potentials to the SHE scale (Standard Hydrogen Electrode). Silver chloride electrodes consist of an inner reference system of silver chloride in equilibrium with a chloride solution. The silver chloride electrode is the most common reference electrode and can be used in several different systems. Platinum electrodes are usually more robust and are particularly suitable to use in BWR environment to follow the hydrogen dosage, but have limitations at low and no hydrogen dosage. Ceramic membrane electrodes can be with different types of internal reference system. They were originally developed for pH measurements in high temperature water. If pH is constant, the membrane electrode can be used as reference electrode. A survey of ceramic reference electrodes for high temperature water is given. A ceramic membrane of the type used works as an oxygen conductor, so the potential and pH in surrounding medium is in equilibrium with the internal reference system. A survey of the lately development of electrodes is presented in order to explain why the different types of electrodes are developed as well as to give a background to the possibilities and limitations with the different electrodes. Possibilities of future development of electrodes are also given. For measurements at low or no hydrogen dosage

  9. Development of beta reference radiations

    International Nuclear Information System (INIS)

    Wan Zhaoyong; Cai Shanyu; Li Yanbo; Yin Wei; Feng Jiamin; Sun Yuhua; Li Yongqiang

    1997-09-01

    A system of beta reference radiation has been developed, that is composed of 740 MBq 147 Pm beta source, 74 MBq and 740 MBq 90 Sr + 90 Y β sources, compensation filters, a source handling tool, a source jig, spacing bars, a shutter, a control unit and a beta dose meter calibration stand. For 740 MBq 147 Pm and 74 MBq 90 Sr + 90 Y beta reference radiations with compensation filters and 740 MBq 90 Sr + 90 Y beta reference radiation without compensation filter, at 20 cm, 30 cm and 30 cm distance separately; the residual energy of maximum is 0.14 MeV, 1.98 MeV and 2.18 MeV separately; the absorbed dose to tissue D (0.07) is 1.547 mGy/h (1996-05-20), 5.037 mGy/h (1996-05-10) and 93.57 mGy/h (1996-05-15) separately; the total uncertainty is 3.0%, 1.7% and 1.7% separately. For the first and the second beta reference radiation, the dose rate variability in the area of 18 cm diameter in the plane perpendicular to the beta-ray beam axis is within +-6% and +-3% separately. (3 refs., 2 tabs., 8 figs.)

  10. The variability of inner ear orientation in saurischian dinosaurs: testing the use of semicircular canals as a reference system for comparative anatomy

    Directory of Open Access Journals (Sweden)

    Jesús Marugán-Lobón

    2013-08-01

    Full Text Available The vestibular system of the inner ear houses three semicircular canals—oriented on three nearly-orthogonal planes—that respond to angular acceleration stimuli. In recent years, the orientation of the lateral semicircular canal (LSC has been regularly used to determine skull orientations for comparative purposes in studies of non-avian dinosaurs. Such orientations have been inferred based on fixing the LSC to a common set of coordinates (parallel to the Earth’s horizon, given that the orientation to gravity of this sensory system is assumed constant among taxa. Under this assumption, the LSC is used as a baseline (a reference system both to estimate how the animals held their heads and to describe craniofacial variation among dinosaurs. However, the available data in living birds (extant saurischian dinosaurs suggests that the orientation of the LSC in non-avian saurischian dinosaurs could have been very variable and taxon-specific. If such were the case, using the LSC as a comparative reference system would cause inappropriate visual perceptions of craniofacial organization, leading to significant descriptive inconsistencies among taxa. Here, we used Procrustes methods (Geometric Morphometrics, a suite of analytical tools that compares morphology on the basis of shared landmark homology, to show that the variability of LSC relative to skull landmarks is large (ca. 50° and likely unpredictable, thus making it an inconsistent reference system for comparing and describing the skulls of saurischian (sauropodomorph and theropod dinosaurs. In light of our results, the lateral semicircular canal is an inconsistent baseline for comparative studies of craniofacial morphology in dinosaurs.

  11. Descriptions of reference LWR facilities for analysis of nuclear fuel cycles

    Energy Technology Data Exchange (ETDEWEB)

    Schneider, K.J.; Kabele, T.J.

    1979-09-01

    To contribute to the Department of Energy's identification of needs for improved environmental controls in nuclear fuel cycles, a study was made of a light water reactor system. A reference LWR fuel cycle was defined, and each step in this cycle was characterized by facility description and mainline and effluent treatment process performance. The reference fuel cycle uses fresh uranium in light water reactors. Final treatment and ultimate disposition of waste from the fuel cycle steps were not included, and the waste is assumed to be disposed of by approved but currently undefined means. The characterization of the reference fuel cycle system is intended as basic information for further evaluation of alternative effluent control systems.

  12. Descriptions of reference LWR facilities for analysis of nuclear fuel cycles

    International Nuclear Information System (INIS)

    Schneider, K.J.; Kabele, T.J.

    1979-09-01

    To contribute to the Department of Energy's identification of needs for improved environmental controls in nuclear fuel cycles, a study was made of a light water reactor system. A reference LWR fuel cycle was defined, and each step in this cycle was characterized by facility description and mainline and effluent treatment process performance. The reference fuel cycle uses fresh uranium in light water reactors. Final treatment and ultimate disposition of waste from the fuel cycle steps were not included, and the waste is assumed to be disposed of by approved but currently undefined means. The characterization of the reference fuel cycle system is intended as basic information for further evaluation of alternative effluent control systems

  13. [Reference citation].

    Science.gov (United States)

    Brkić, Silvija

    2013-01-01

    Scientific and professional papers represent the information basis for scientific research and professional work. References important for the paper should be cited within the text, and listed at the end of the paper. This paper deals with different styles of reference citation. Special emphasis was placed on the Vancouver Style for reference citation in biomedical journals established by the International Committee of Medical Journal Editors. It includes original samples for citing various types of articles, both printed and electronic, as well as recommendations related to reference citation in accordance with the methodology and ethics of scientific research and guidelines for preparing manuscripts for publication.

  14. The project manager's desk reference: project planning, schedulding, evaluation, control, systems

    National Research Council Canada - National Science Library

    Lewis, James P

    2007-01-01

    In this Third Edition of The Project Manager's Desk Reference, top project management consultant James Lewis arms you with today's most comprehensive and understandable project management resources...

  15. Mounting system for optical frequency reference cavities

    Science.gov (United States)

    Notcutt, Mark (Inventor); Hall, John L. (Inventor); Ma, Long-Sheng (Inventor)

    2008-01-01

    A technique for reducing the vibration sensitivity of laser-stabilizing optical reference cavities is based upon an improved design and mounting method for the cavity, wherein the cavity is mounted vertically. It is suspended at one plane, around the spacer cylinder, equidistant from the mirror ends of the cavity. The suspension element is a collar of an extremely low thermal expansion coefficient material, which surrounds the spacer cylinder and contacts it uniformly. Once the collar has been properly located, it is cemented in place so that the spacer cylinder is uniformly supported and does not have to be squeezed at all. The collar also includes a number of cavities partially bored into its lower flat surface, around the axial bore. These cavities are support points, into which mounting base pins will be inserted. Hence the collar is supported at a minimum of three points.

  16. Quantum frames of reference

    International Nuclear Information System (INIS)

    Kaufherr, T.

    1981-01-01

    The idea that only relative variables have physical meaning came to be known as Mach's principle. Carrying over this idea to quantum theory, has led to the consideration of finite mass, macroscopic reference frames, relative to which all physical quantities are measured. During the process of measurement, a finite mass observer receives a kickback, and this reaction of the measuring device is not negligible in quantum theory because of the quantization of the action. Hence, the observer himself has to be included in the system that is being considered. Using this as the starting point, a number of thought experiments involving finite mass observers is discussed which have quantum uncertainties in their time or in their position. These thought experiments serve to elucidate in a qualitative way some of the difficulties involved, as well as pointing out a direction to take in seeking solutions to them. When the discussion is extended to include more than one observer, the question of the covariance of the theory immediately arises. Because none of the frames of reference should be preferred, the theory should be covariant. This demand expresses an equivalence principle which here is extended to include reference frames which are in quantum uncertainties relative to each other. Formulating the problem in terms of canonical variables, the ensueing free Hamiltonian contains vector and scalar potentials which represent the kick that the reference frame receives during measurement. These are essentially gravitational type potentials, resulting, as it were, from the extension of the equivalence principle into the quantum domain

  17. Project summary plan for HTGR recycle reference facility

    International Nuclear Information System (INIS)

    Baxter, B.J.

    1979-11-01

    A summary plan is introduced for completing conceptual definition of an HTGR Recycle Reference Facility (HRRF). The plan describes a generic project management concept, often referred to as the requirements approach to systems engineering. The plan begins with reference flow sheets and provides for the progressive evolution of HRRF requirements and definition through feasibility, preconceptual, and conceptual phases. The plan lays end-to-end all the important activities and elements to be treated during each phase of design. Identified activities and elements are further supported by technical guideline documents, which describe methodology, needed terminology, and where relevant a worked example

  18. REFERENCE MATERIALS IN THE SPHERE OF USE OF ATOMIC ENERGY

    Directory of Open Access Journals (Sweden)

    V. A. Borisov

    2015-01-01

    Full Text Available The article describes the chronology of development of the system of reference materials in the nuclear industry of the Russian Federation. The basic documents used in the sphere of nuclear energy are described. The nomenclature of reference materials and feature of their application in the "Rosatom" is given. The prospects of development activities in the field of reference materials are formulated.

  19. Considerations for reference pump curves

    International Nuclear Information System (INIS)

    Stockton, N.B.

    1992-01-01

    This paper examines problems associated with inservice testing (IST) of pumps to assess their hydraulic performance using reference pump curves to establish acceptance criteria. Safety-related pumps at nuclear power plants are tested under the American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code (the Code), Section 11. The Code requires testing pumps at specific reference points of differential pressure or flow rate that can be readily duplicated during subsequent tests. There are many cases where test conditions cannot be duplicated. For some pumps, such as service water or component cooling pumps, the flow rate at any time depends on plant conditions and the arrangement of multiple independent and constantly changing loads. System conditions cannot be controlled to duplicate a specific reference value. In these cases, utilities frequently request to use pump curves for comparison of test data for acceptance. There is no prescribed method for developing a pump reference curve. The methods vary and may yield substantially different results. Some results are conservative when compared to the Code requirements; some are not. The errors associated with different curve testing techniques should be understood and controlled within reasonable bounds. Manufacturer's pump curves, in general, are not sufficiently accurate to use as reference pump curves for IST. Testing using reference curves generated with polynomial least squares fits over limited ranges of pump operation, cubic spline interpolation, or cubic spline least squares fits can provide a measure of pump hydraulic performance that is at least as accurate as the Code required method. Regardless of the test method, error can be reduced by using more accurate instruments, by correcting for systematic errors, by increasing the number of data points, and by taking repetitive measurements at each data point

  20. VBScript pocket reference

    CERN Document Server

    Lomax, Paul; Petrusha, Ron

    2008-01-01

    Microsoft's Visual Basic Scripting Edition (VBScript), a subset of Visual Basic for Applications, is a powerful language for Internet application development, where it can serve as a scripting language for server-side, client-side, and system scripting. Whether you're developing code for Active Server Pages, client-side scripts for Internet Explorer, code for Outlook forms, or scripts for Windows Script Host, VBScript Pocket Reference will be your constant companion. Don't let the pocket-friendly format fool you. Based on the bestsellingVBScript in a Nutshell, this small book details every V

  1. A reference aerosol for a radon reference chamber

    Science.gov (United States)

    Paul, Annette; Keyser, Uwe

    1996-02-01

    The measurement of radon and radon progenies and the calibration of their detection systems require the production and measurement of aerosols well-defined in size and concentration. In the German radon reference chamber, because of its unique chemical and physical properties, carnauba wax is used to produce standard aerosols. The aerosol size spectra are measured on-line by an aerosol measurement system in the range of 10 nm to 1 μm aerodynamic diameter. The experimental set-ups for the study of adsorption of radioactive ions on aerosols as function of their size and concentration will be described, the results presented and further adaptations for an aerosol jet introduced (for example, for the measurement of short-lived neutron-rich isotopes). Data on the dependence of aerosol radius, ion concentration and element selectivity is collected by using a 252Cf-sf source. The fission products of this source range widely in elements, isotopes and charges. Adsorption and the transport of radioactive ions on aerosols have therefore been studied for various ions for the first time, simultaneously with the aerosol size on-line spectrometry.

  2. A reference aerosol for a radon reference chamber

    Energy Technology Data Exchange (ETDEWEB)

    Paul, A. [Physikalisch-Technische Bundesanstalt, Braunschweig (Germany); Keyser, U. [Physikalisch-Technische Bundesanstalt, Braunschweig (Germany)

    1996-01-11

    The measurement of radon and radon progenies and the calibration of their detection systems require the production and measurement of aerosols well-defined in size and concentration. In the German radon reference chamber, because of its unique chemical and physical properties, carnauba wax is used to produce standard aerosols. The aerosol size spectra are measured on-line by an aerosol measurement system in the range of 10 nm to 1 {mu}m aerodynamic diameter. The experimental set-ups for the study of adsorption of radioactive ions on aerosols as function of their size and concentration are described, the results presented and further adaptations for an aerosol jet introduced (for example, for the measurement of short-lived neutron-rich isotopes). Data on the dependence of aerosol radius, ion concentration and element selectivity is collected by using a {sup 252}Cf-sf source. The fission products of this source range widely in elements, isotopes and charges. Adsorption and the transport of radioactive ions on aerosols have therefore been studied for various ions for the first time, simultaneously with the aerosol size on-line spectrometry. (orig.).

  3. A First Look at the Upcoming SISO Space Reference FOM

    Science.gov (United States)

    Mueller, Bjorn; Crues, Edwin Z.; Dexter, Dan; Garro, Alfredo; Skuratovskiy, Anton; Vankov, Alexander

    2016-01-01

    Spaceflight is difficult, dangerous and expensive; human spaceflight even more so. In order to mitigate some of the danger and expense, professionals in the space domain have relied, and continue to rely, on computer simulation. Simulation is used at every level including concept, design, analysis, construction, testing, training and ultimately flight. As space systems have grown more complex, new simulation technologies have been developed, adopted and applied. Distributed simulation is one those technologies. Distributed simulation provides a base technology for segmenting these complex space systems into smaller, and usually simpler, component systems or subsystems. This segmentation also supports the separation of responsibilities between participating organizations. This segmentation is particularly useful for complex space systems like the International Space Station (ISS), which is composed of many elements from many nations along with visiting vehicles from many nations. This is likely to be the case for future human space exploration activities. Over the years, a number of distributed simulations have been built within the space domain. While many use the High Level Architecture (HLA) to provide the infrastructure for interoperability, HLA without a Federation Object Model (FOM) is insufficient by itself to insure interoperability. As a result, the Simulation Interoperability Standards Organization (SISO) is developing a Space Reference FOM. The Space Reference FOM Product Development Group is composed of members from several countries. They contribute experiences from projects within NASA, ESA and other organizations and represent government, academia and industry. The initial version of the Space Reference FOM is focusing on time and space and will provide the following: (i) a flexible positioning system using reference frames for arbitrary bodies in space, (ii) a naming conventions for well-known reference frames, (iii) definitions of common time scales

  4. Long-term pavement performance ancillary information management system (AIMS) reference guide.

    Science.gov (United States)

    2012-11-01

    This document provides information on the Long-Term Pavement Performance (LTPP) program ancillary information. : Ancillary information includes data, images, reference materials, resource documents, and other information that : support and extend the...

  5. A structural SVM approach for reference parsing.

    Science.gov (United States)

    Zhang, Xiaoli; Zou, Jie; Le, Daniel X; Thoma, George R

    2011-06-09

    Automated extraction of bibliographic data, such as article titles, author names, abstracts, and references is essential to the affordable creation of large citation databases. References, typically appearing at the end of journal articles, can also provide valuable information for extracting other bibliographic data. Therefore, parsing individual reference to extract author, title, journal, year, etc. is sometimes a necessary preprocessing step in building citation-indexing systems. The regular structure in references enables us to consider reference parsing a sequence learning problem and to study structural Support Vector Machine (structural SVM), a newly developed structured learning algorithm on parsing references. In this study, we implemented structural SVM and used two types of contextual features to compare structural SVM with conventional SVM. Both methods achieve above 98% token classification accuracy and above 95% overall chunk-level accuracy for reference parsing. We also compared SVM and structural SVM to Conditional Random Field (CRF). The experimental results show that structural SVM and CRF achieve similar accuracies at token- and chunk-levels. When only basic observation features are used for each token, structural SVM achieves higher performance compared to SVM since it utilizes the contextual label features. However, when the contextual observation features from neighboring tokens are combined, SVM performance improves greatly, and is close to that of structural SVM after adding the second order contextual observation features. The comparison of these two methods with CRF using the same set of binary features show that both structural SVM and CRF perform better than SVM, indicating their stronger sequence learning ability in reference parsing.

  6. A Reference Model for Virtual Machine Launching Overhead

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Hao; Ren, Shangping; Garzoglio, Gabriele; Timm, Steven; Bernabeu, Gerard; Chadwick, Keith; Noh, Seo-Young

    2016-07-01

    Cloud bursting is one of the key research topics in the cloud computing communities. A well designed cloud bursting module enables private clouds to automatically launch virtual machines (VMs) to public clouds when more resources are needed. One of the main challenges in developing a cloud bursting module is to decide when and where to launch a VM so that all resources are most effectively and efficiently utilized and the system performance is optimized. However, based on system operational data obtained from FermiCloud, a private cloud developed by the Fermi National Accelerator Laboratory for scientific workflows, the VM launching overhead is not a constant. It varies with physical resource utilization, such as CPU and I/O device utilizations, at the time when a VM is launched. Hence, to make judicious decisions as to when and where a VM should be launched, a VM launching overhead reference model is needed. In this paper, we first develop a VM launching overhead reference model based on operational data we have obtained on FermiCloud. Second, we apply the developed reference model on FermiCloud and compare calculated VM launching overhead values based on the model with measured overhead values on FermiCloud. Our empirical results on FermiCloud indicate that the developed reference model is accurate. We believe, with the guidance of the developed reference model, efficient resource allocation algorithms can be developed for cloud bursting process to minimize the operational cost and resource waste.

  7. NEURO-SYSTEM OF AIMING AND STABILIZING WITH A REGULATOR ON THE BASIS OF STANDARD MODEL MODEL REFERENCE CONTROLLER

    Directory of Open Access Journals (Sweden)

    B.I. Kuznetsov

    2015-08-01

    Full Text Available The aim of this work is the synthesis of neural network aiming and stabilization system for the special equipment of moving objects with neuro-controller on the basis of standard model and performance comparison of the neural network system with the neural network predictive control. Build a block diagram of the neural network aiming and stabilization system, based on the subject control principle with PD-regulator in the position loop and with neuro-controller on the basis of standard model in the in the velocity loop. The neuro-controller on the basis of standard model Model Reference Controller is synthesized in the MATLAB Neural Network Toolbox and system simulation is performed. The studies show that the transient state variables of the system are oscillatory. Therefore, the neuro-controller with the prediction NN Predictive Controller should be used for aiming and stabilizing system to provide high dynamic characteristics achieved at the cost of higher complexity and computational cost.

  8. Towards dynamic reference information models: Readiness for ICT mass customisation

    NARCIS (Netherlands)

    Verdouw, C.N.; Beulens, A.J.M.; Trienekens, J.H.; Verwaart, D.

    2010-01-01

    Current dynamic demand-driven networks make great demands on, in particular, the interoperability and agility of information systems. This paper investigates how reference information models can be used to meet these demands by enhancing ICT mass customisation. It was found that reference models for

  9. Describing, Instantiating and Evaluating a Reference Architecture : A Case Study

    NARCIS (Netherlands)

    Avgeriou, Paris

    2003-01-01

    The result of a domain maturing is the emergence of reference architectures that offer numerous advantages to software architects and other stakeholders. However there is no straightforward way to describe a reference architecture and in sequence to design instances for specific systems, while at

  10. A Wireless Swing Angle Measurement Scheme Using Attitude Heading Reference System Sensing Units Based on Microelectromechanical Devices

    Directory of Open Access Journals (Sweden)

    Bingtuan Gao

    2014-11-01

    Full Text Available Feasible real-time swing angle measurement is significant to improve the efficiency and safety of industrial crane systems. This paper presents a wireless microelectromechanical system (MEMS-based swing angle measurement system. The system consists of two attitude heading reference system (AHRS sensing units with a wireless communication function, which are mounted on the hook (or payload and the jib (or base of the crane, respectively. With a combination of a three-axis accelerometer, a three-axis gyroscope and a three-axis magnetometer, the standard extended Kalman filter (EKF is used to estimate the desired orientation of the payload and the base. Wireless ZigBee communication is employed to transmit the orientation of the payload to the sensing unit mounted on the base, which measures the orientation of the base. Because several physical parameters from the payload to the base can be acquired from the original crane control system, the swing angles of the payload can be calculated based on the two measured orientation parameters together with the known physical parameters. Experiments were performed to show the feasibility and effectiveness of the proposed swing angle measurement system.

  11. NASA/NBS (National Aeronautics and Space Administration/National Bureau of Standards) standard reference model for telerobot control system architecture (NASREM)

    Science.gov (United States)

    Albus, James S.; Mccain, Harry G.; Lumia, Ronald

    1989-01-01

    The document describes the NASA Standard Reference Model (NASREM) Architecture for the Space Station Telerobot Control System. It defines the functional requirements and high level specifications of the control system for the NASA space Station document for the functional specification, and a guideline for the development of the control system architecture, of the 10C Flight Telerobot Servicer. The NASREM telerobot control system architecture defines a set of standard modules and interfaces which facilitates software design, development, validation, and test, and make possible the integration of telerobotics software from a wide variety of sources. Standard interfaces also provide the software hooks necessary to incrementally upgrade future Flight Telerobot Systems as new capabilities develop in computer science, robotics, and autonomous system control.

  12. Oncogenetics service and the Brazilian public health system: the experience of a reference Cancer Hospital.

    Science.gov (United States)

    Palmero, Edenir I; Galvão, Henrique C R; Fernandes, Gabriela C; Paula, André E de; Oliveira, Junea C; Souza, Cristiano P; Andrade, Carlos E; Romagnolo, Luis G C; Volc, Sahlua; C Neto, Maximiliano; Sabato, Cristina; Grasel, Rebeca; Mauad, Edmundo; Reis, Rui M; Michelli, Rodrigo A D

    2016-05-13

    The identification of families at-risk for hereditary cancer is extremely important due to the prevention potential in those families. However, the number of Brazilian genetic services providing oncogenetic care is extremely low for the continental dimension of the country and its population. Therefore, at-risk patients do not receive appropriate assistance. This report describes the creation, structure and management of a cancer genetics service in a reference center for cancer prevention and treatment, the Barretos Cancer Hospital (BCH). The Oncogenetics Department (OD) of BCH offers, free of charge, to all patients/relatives with clinical criteria, the possibility to perform i) genetic counseling, ii) preventive examinations and iii) genetic testing with the best quality standards. The OD has a multidisciplinary team and is integrated with all specialties. The genetic counseling process consists (mostly) of two visits. In 2014, 614 individuals (371 families) were seen by the OD. To date, over 800 families were referred by the OD for genetic testing. The support provided by the Oncogenetics team is crucial to identify at-risk individuals and to develop preventive and personalized behaviors for each situation, not only to the upper-middle class population, but also to the people whose only possibility is the public health system.

  13. Behavioral Reference Model for Pervasive Healthcare Systems.

    Science.gov (United States)

    Tahmasbi, Arezoo; Adabi, Sahar; Rezaee, Ali

    2016-12-01

    The emergence of mobile healthcare systems is an important outcome of application of pervasive computing concepts for medical care purposes. These systems provide the facilities and infrastructure required for automatic and ubiquitous sharing of medical information. Healthcare systems have a dynamic structure and configuration, therefore having an architecture is essential for future development of these systems. The need for increased response rate, problem limited storage, accelerated processing and etc. the tendency toward creating a new generation of healthcare system architecture highlight the need for further focus on cloud-based solutions for transfer data and data processing challenges. Integrity and reliability of healthcare systems are of critical importance, as even the slightest error may put the patients' lives in danger; therefore acquiring a behavioral model for these systems and developing the tools required to model their behaviors are of significant importance. The high-level designs may contain some flaws, therefor the system must be fully examined for different scenarios and conditions. This paper presents a software architecture for development of healthcare systems based on pervasive computing concepts, and then models the behavior of described system. A set of solutions are then proposed to improve the design's qualitative characteristics including, availability, interoperability and performance.

  14. World Reference Base for Soil Resources

    NARCIS (Netherlands)

    Deckers, J.A.; Driessen, P.M.; Nachtergaele, F.O.; Spaargaren, O.C.

    2002-01-01

    In 1998, the International Union of Soil Sciences (IUSS) officially adopted the world reference base for soil resources (WRB) as the Union's system for soil correlation. The structure, concepts, and definitions of the WRB are strongly influenced by the FAO-UNESCO legend of the soil map of the world

  15. Errors in the SAP reference model

    NARCIS (Netherlands)

    Mendling, J.; Aalst, van der W.M.P.; Dongen, van B.F.; Verbeek, H.M.W.

    2006-01-01

    The SAP Reference Model is a set of information models that is utilized to guide the configuration of SAP systems. A big part of these models are business process models represented in the Eventdriven Process Chains (EPC) notation. These EPC models provide a easy to comprehend overview of SAP

  16. 41 CFR 105-1.109-52 - Cross-references.

    Science.gov (United States)

    2010-07-01

    ... 41 Public Contracts and Property Management 3 2010-07-01 2010-07-01 false Cross-references. 105-1.109-52 Section 105-1.109-52 Public Contracts and Property Management Federal Property Management Regulations System (Continued) GENERAL SERVICES ADMINISTRATION 1-INTRODUCTION 1.1-Regulations System § 105-1...

  17. A model reference and sensitivity model-based self-learning fuzzy logic controller as a solution for control of nonlinear servo systems

    NARCIS (Netherlands)

    Kovacic, Z.; Bogdan, S.; Balenovic, M.

    1999-01-01

    In this paper, the design, simulation and experimental verification of a self-learning fuzzy logic controller (SLFLC) suitable for the control of nonlinear servo systems are described. The SLFLC contains a learning algorithm that utilizes a second-order reference model and a sensitivity model

  18. 48 CFR 552.211-72 - Reference to Specifications in Drawings.

    Science.gov (United States)

    2010-10-01

    ... Specifications in Drawings. 552.211-72 Section 552.211-72 Federal Acquisition Regulations System GENERAL SERVICES....211-72 Reference to Specifications in Drawings. As prescribed in 511.204(a), insert the following clause: References to Specifications in Drawings (FEB 1996) If military or other drawings are made a part...

  19. Enterprise Reference Library

    Science.gov (United States)

    Bickham, Grandin; Saile, Lynn; Havelka, Jacque; Fitts, Mary

    2011-01-01

    Introduction: Johnson Space Center (JSC) offers two extensive libraries that contain journals, research literature and electronic resources. Searching capabilities are available to those individuals residing onsite or through a librarian s search. Many individuals have rich collections of references, but no mechanisms to share reference libraries across researchers, projects, or directorates exist. Likewise, information regarding which references are provided to which individuals is not available, resulting in duplicate requests, redundant labor costs and associated copying fees. In addition, this tends to limit collaboration between colleagues and promotes the establishment of individual, unshared silos of information The Integrated Medical Model (IMM) team has utilized a centralized reference management tool during the development, test, and operational phases of this project. The Enterprise Reference Library project expands the capabilities developed for IMM to address the above issues and enhance collaboration across JSC. Method: After significant market analysis for a multi-user reference management tool, no available commercial tool was found to meet this need, so a software program was built around a commercial tool, Reference Manager 12 by The Thomson Corporation. A use case approach guided the requirements development phase. The premise of the design is that individuals use their own reference management software and export to SharePoint when their library is incorporated into the Enterprise Reference Library. This results in a searchable user-specific library application. An accompanying share folder will warehouse the electronic full-text articles, which allows the global user community to access full -text articles. Discussion: An enterprise reference library solution can provide a multidisciplinary collection of full text articles. This approach improves efficiency in obtaining and storing reference material while greatly reducing labor, purchasing and

  20. The cost of model reference adaptive control - Analysis, experiments, and optimization

    Science.gov (United States)

    Messer, R. S.; Haftka, R. T.; Cudney, H. H.

    1993-01-01

    In this paper the performance of Model Reference Adaptive Control (MRAC) is studied in numerical simulations and verified experimentally with the objective of understanding how differences between the plant and the reference model affect the control effort. MRAC is applied analytically and experimentally to a single degree of freedom system and analytically to a MIMO system with controlled differences between the model and the plant. It is shown that the control effort is sensitive to differences between the plant and the reference model. The effects of increased damping in the reference model are considered, and it is shown that requiring the controller to provide increased damping actually decreases the required control effort when differences between the plant and reference model exist. This result is useful because one of the first attempts to counteract the increased control effort due to differences between the plant and reference model might be to require less damping, however, this would actually increase the control effort. Optimization of weighting matrices is shown to help reduce the increase in required control effort. However, it was found that eventually the optimization resulted in a design that required an extremely high sampling rate for successful realization.

  1. Application of the informational reference system OZhUR to the automated processing of data from satellites of the Kosmos series

    Science.gov (United States)

    Pokras, V. M.; Yevdokimov, V. P.; Maslov, V. D.

    1978-01-01

    The structure and potential of the information reference system OZhUR designed for the automated data processing systems of scientific space vehicles (SV) is considered. The system OZhUR ensures control of the extraction phase of processing with respect to a concrete SV and the exchange of data between phases.The practical application of the system OZhUR is exemplified in the construction of a data processing system for satellites of the Cosmos series. As a result of automating the operations of exchange and control, the volume of manual preparation of data is significantly reduced, and there is no longer any need for individual logs which fix the status of data processing. The system Ozhur is included in the automated data processing system Nauka which is realized in language PL-1 in a binary one-address system one-state (BOS OS) electronic computer.

  2. Automation of Precise Time Reference Stations (PTRS)

    Science.gov (United States)

    Wheeler, P. J.

    1985-04-01

    The U.S. Naval Observatory is presently engaged in a program of automating precise time stations (PTS) and precise time reference stations (PTBS) by using a versatile mini-computer controlled data acquisition system (DAS). The data acquisition system is configured to monitor locally available PTTI signals such as LORAN-C, OMEGA, and/or the Global Positioning System. In addition, the DAS performs local standard intercomparison. Computer telephone communications provide automatic data transfer to the Naval Observatory. Subsequently, after analysis of the data, results and information can be sent back to the precise time reference station to provide automatic control of remote station timing. The DAS configuration is designed around state of the art standard industrial high reliability modules. The system integration and software are standardized but allow considerable flexibility to satisfy special local requirements such as stability measurements, performance evaluation and printing of messages and certificates. The DAS operates completely independently and may be queried or controlled at any time with a computer or terminal device (control is protected for use by authorized personnel only). Such DAS equipped PTS are operational in Hawaii, California, Texas and Florida.

  3. 2002 reference document; Document de reference 2002

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2002-07-01

    This 2002 reference document of the group Areva, provides information on the society. Organized in seven chapters, it presents the persons responsible for the reference document and for auditing the financial statements, information pertaining to the transaction, general information on the company and share capital, information on company operation, changes and future prospects, assets, financial position, financial performance, information on company management and executive board and supervisory board, recent developments and future prospects. (A.L.B.)

  4. Precision Tiltmeter as a Reference for Slope MeasuringInstruments

    Energy Technology Data Exchange (ETDEWEB)

    Kirschman, Jonathan L.; Domning, Edward E.; Morrison, Gregory Y.; Smith, Brian V.; Yashchuk, Valeriy V.

    2007-08-01

    The next generation of synchrotrons and free electron lasers require extremely high-performance x-ray optical systems for proper focusing. The necessary optics cannot be fabricated without the use of precise optical metrology instrumentation. In particular, the Long Trace Profiler (LTP) based on the pencil-beam interferometer is a valuable tool for low-spatial-frequency slope measurement with x-ray optics. The limitations of such a device are set by the amount of systematic errors and noise. A significant improvement of LTP performance was the addition of an optical reference channel, which allowed to partially account for systematic errors associated with wiggling and wobbling of the LTP carriage. However, the optical reference is affected by changing optical path length, non-homogeneous optics, and air turbulence. In the present work, we experimentally investigate the questions related to the use of a precision tiltmeter as a reference channel. Dependence of the tiltmeter performance on horizontal acceleration, temperature drift, motion regime, and kinematical scheme of the translation stage has been investigated. It is shown that at an appropriate experimental arrangement, the tiltmeter provides a slope reference for the LTP system with accuracy on the level of 0.1 {micro}rad (rms).

  5. Precision Tiltmeter as a Reference for Slope Measuring Instruments

    International Nuclear Information System (INIS)

    Kirschman, Jonathan L.; Domning, Edward E.; Morrison, Gregory Y.; Smith, Brian V.; Yashchuk, Valeriy V.

    2007-01-01

    The next generation of synchrotrons and free electron lasers require extremely high-performance x-ray optical systems for proper focusing. The necessary optics cannot be fabricated without the use of precise optical metrology instrumentation. In particular, the Long Trace Profiler (LTP) based on the pencil-beam interferometer is a valuable tool for low-spatial-frequency slope measurement with x-ray optics. The limitations of such a device are set by the amount of systematic errors and noise. A significant improvement of LTP performance was the addition of an optical reference channel, which allowed to partially account for systematic errors associated with wiggling and wobbling of the LTP carriage. However, the optical reference is affected by changing optical path length, non-homogeneous optics, and air turbulence. In the present work, we experimentally investigate the questions related to the use of a precision tiltmeter as a reference channel. Dependence of the tiltmeter performance on horizontal acceleration, temperature drift, motion regime, and kinematical scheme of the translation stage has been investigated. It is shown that at an appropriate experimental arrangement, the tiltmeter provides a slope reference for the LTP system with accuracy on the level of 0.1 (micro)rad (rms)

  6. Reference ranges for hematocrit and blood hemoglobin concentration during the neonatal period: data from a multihospital health care system.

    Science.gov (United States)

    Jopling, Jeffery; Henry, Erick; Wiedmeier, Susan E; Christensen, Robert D

    2009-02-01

    "Reference ranges" are developed when it is impossible or inappropriate to establish "normal ranges" by drawing blood on healthy normal volunteers. Reference ranges for the hematocrit and the blood hemoglobin concentration of newborn infants have previously been reported from relatively small sample sizes by using measurement methods that now are considered outmoded. We sought to develop reference ranges for hematocrit and hemoglobin during the neonatal period (28 days) by using very large sample sizes and modern hematology analyzers, accounting for gestational and postnatal age and gender. Data were assembled from a multihospital health care system after exclusion of patients with a high likelihood of an abnormal value and those who were receiving blood transfusions. During the interval from 22 to 40 weeks' gestation, the hematocrit and blood hemoglobin concentration increased approximately linearly. For every week advance in gestational age, the hematocrit increased by 0.64% and the hemoglobin concentration increased by 0.21 g/dL. No difference was seen on the basis of gender. During the 4-hour interval after birth, hematocrit/hemoglobin values of late preterm and term neonates (35-42 weeks' gestation) increased by 3.6% +/- 0.5% (mean +/- SD), those of neonates of 29 to 34 weeks' gestation remained unchanged, and those of hematocrit/hemoglobin occurred. The figures presented herein describe reference ranges for hematocrit and blood hemoglobin concentration during the neonatal period, accounting for gestational and postnatal age.

  7. A coarse-graining approach for molecular simulation that retains the dynamics of the all-atom reference system by implementing hydrodynamic interactions

    Energy Technology Data Exchange (ETDEWEB)

    Markutsya, Sergiy [Ames Laboratory, Iowa State University, Ames, Iowa 50011 (United States); Lamm, Monica H., E-mail: mhlamm@iastate.edu [Ames Laboratory, Iowa State University, Ames, Iowa 50011 (United States); Department of Chemical and Biological Engineering, Iowa State University, Ames, Iowa 50011 (United States)

    2014-11-07

    We report on a new approach for deriving coarse-grained intermolecular forces that retains the frictional contribution that is often discarded by conventional coarse-graining methods. The approach is tested for water and an aqueous glucose solution, and the results from the new implementation for coarse-grained molecular dynamics simulation show remarkable agreement with the dynamics obtained from reference all-atom simulations. The agreement between the structural properties observed in the coarse-grained and all-atom simulations is also preserved. We discuss how this approach may be applied broadly to any existing coarse-graining method where the coarse-grained models are rigorously derived from all-atom reference systems.

  8. A coarse-graining approach for molecular simulation that retains the dynamics of the all-atom reference system by implementing hydrodynamic interactions

    International Nuclear Information System (INIS)

    Markutsya, Sergiy; Lamm, Monica H.

    2014-01-01

    We report on a new approach for deriving coarse-grained intermolecular forces that retains the frictional contribution that is often discarded by conventional coarse-graining methods. The approach is tested for water and an aqueous glucose solution, and the results from the new implementation for coarse-grained molecular dynamics simulation show remarkable agreement with the dynamics obtained from reference all-atom simulations. The agreement between the structural properties observed in the coarse-grained and all-atom simulations is also preserved. We discuss how this approach may be applied broadly to any existing coarse-graining method where the coarse-grained models are rigorously derived from all-atom reference systems

  9. Metaphorical Singular Reference. The Role of Enriched Composition in Reference Resolution

    Directory of Open Access Journals (Sweden)

    Anne Bezuidenhout

    2008-08-01

    Full Text Available It is widely accepted that, in the course of interpreting a metaphorical utterance, both literal and metaphorical interpretations of the utterance are available to the interpreter, although there may be disagreement about the order in which these interpretations are accessed. I call this the dual availability assumption. I argue that it does not apply in cases of metaphorical singular reference. These are cases in which proper names, complex demonstratives or definite descriptions are used metaphorically; e.g., ‘That festering sore must go’, referring to a derelict house. We are forced to give up dual availability in these cases because a process of predicate transfer happens in the restriction clauses of such metaphorically used definite phrases (DPs, so that a denotation-less definite concept is never constructed. A process of enriched composition yields only a metaphorical referent/denotation. I compare cases of metaphorical reference both to cases of metonymic reference and to uses of epithets of the ‘That N of an N’ form. Reflection on the former is helpful in getting clear about the kind of property transfer involved in referential metaphors. Such transfer happens directly at the level of properties and is not mediated via a correspondence between objects, as is the case with metonymic reference. Reflection on epithets such as ‘that festering sore of a house’ is helpful since these are a sort of intermediate case between cases of literal and metaphorical reference. They provide support for my claim that in cases of metaphorical reference there is only a single referent (the metaphorical one. Moreover, constraints on the use of these epithets suggest that referential metaphors are similarly constrained. In particular, I argue that referential metaphors can only be used when the implicit category restriction (e.g., house in the case of the example ‘That festering sore must go’ is highly salient, and that the evaluative

  10. Material control system simulator program reference manual

    Energy Technology Data Exchange (ETDEWEB)

    Hollstien, R.B.

    1978-01-24

    A description is presented of a Material Control System Simulator (MCSS) program for determination of material accounting uncertainty and system response to particular adversary action sequences that constitute plausible material diversion attempts. The program is intended for use in situations where randomness, uncertainty, or interaction of adversary actions and material control system components make it difficult to assess safeguards effectiveness against particular material diversion attempts. Although MCSS may be used independently in the design or analysis of material handling and processing systems, it has been tailored toward the determination of material accountability and the response of material control systems to adversary action sequences.

  11. Material control system simulator program reference manual

    International Nuclear Information System (INIS)

    Hollstien, R.B.

    1978-01-01

    A description is presented of a Material Control System Simulator (MCSS) program for determination of material accounting uncertainty and system response to particular adversary action sequences that constitute plausible material diversion attempts. The program is intended for use in situations where randomness, uncertainty, or interaction of adversary actions and material control system components make it difficult to assess safeguards effectiveness against particular material diversion attempts. Although MCSS may be used independently in the design or analysis of material handling and processing systems, it has been tailored toward the determination of material accountability and the response of material control systems to adversary action sequences

  12. Overall properties of the Gaia DR1 reference frame

    Science.gov (United States)

    Liu, N.; Zhu, Z.; Liu, J.-C.; Ding, C.-Y.

    2017-03-01

    Aims: The first Gaia data release (Gaia DR1) provides 2191 ICRF2 sources with their positions in the auxiliary quasar solution and five astrometric parameters - positions, parallaxes, and proper motions - for stars in common between the Tycho-2 catalogue and Gaia in the joint Tycho-Gaia astrometric solution (TGAS). We aim to analyze the overall properties of Gaia DR1 reference frame. Methods: We compare quasar positions of the auxiliary quasar solution with ICRF2 sources using different samples and evaluate the influence on the Gaia DR1 reference frame owing to the Galactic aberration effect over the J2000.0-J2015.0 period. Then we estimate the global rotation between TGAS with Tycho-2 proper motion systems to investigate the property of the Gaia DR1 reference frame. Finally, the Galactic kinematics analysis using the K-M giant proper motions is performed to understand the property of Gaia DR1 reference frame. Results: The positional comparison between the auxiliary quasar solution and ICRF2 shows negligible orientation and validates the declination bias of -0.1mas in Gaia quasar positions with respect to ICRF2. Galactic aberration effect is thought to cause an offset 0.01mas of the Z axis direction of Gaia DR1 reference frame. The global rotation between TGAS and Tycho-2 proper motion systems, obtained by different samples, shows a much smaller value than the claimed value 0.24mas yr-1. For the Galactic kinematics analysis of the TGAS K-M giants, we find possible non-zero Galactic rotation components beyond the classical Oort constants: the rigid part ωYG = -0.38±0.15mas yr-1 and the differential part ω^primeYG = -0.29±0.19mas yr-1 around the YG axis of Galactic coordinates, which indicates possible residual rotation in Gaia DR1 reference frame or problems in the current Galactic kinematical model. Conclusions: The Gaia DR1 reference frame is well aligned to ICRF2, and the possible influence of the Galactic aberration effect should be taken into consideration

  13. Context controls access to working and reference memory in the pigeon (Columba livia).

    Science.gov (United States)

    Roberts, William A; Macpherson, Krista; Strang, Caroline

    2016-01-01

    The interaction between working and reference memory systems was examined under conditions in which salient contextual cues were presented during memory retrieval. Ambient colored lights (red or green) bathed the operant chamber during the presentation of comparison stimuli in delayed matching-to-sample training (working memory) and during the presentation of the comparison stimuli as S+ and S- cues in discrimination training (reference memory). Strong competition between memory systems appeared when the same contextual cue appeared during working and reference memory training. When different contextual cues were used, however, working memory was completely protected from reference memory interference. © 2016 Society for the Experimental Analysis of Behavior.

  14. The Computerized Reference Department: Buying the Future.

    Science.gov (United States)

    Kriz, Harry M.; Kok, Victoria T.

    1985-01-01

    Basis for systematic computerization of academic research library's reference, collection development, and collection management functions emphasizes productivity enhancement for librarians and support staff. Use of microcomputer and university's mainframe computer to develop applications of database management systems, electronic spreadsheets,…

  15. Fit Gap Analysis – The Role of Business Process Reference Models

    Directory of Open Access Journals (Sweden)

    Dejan Pajk

    2013-12-01

    Full Text Available Enterprise resource planning (ERP systems support solutions for standard business processes such as financial, sales, procurement and warehouse. In order to improve the understandability and efficiency of their implementation, ERP vendors have introduced reference models that describe the processes and underlying structure of an ERP system. To select and successfully implement an ERP system, the capabilities of that system have to be compared with a company’s business needs. Based on a comparison, all of the fits and gaps must be identified and further analysed. This step usually forms part of ERP implementation methodologies and is called fit gap analysis. The paper theoretically overviews methods for applying reference models and describes fit gap analysis processes in detail. The paper’s first contribution is its presentation of a fit gap analysis using standard business process modelling notation. The second contribution is the demonstration of a process-based comparison approach between a supply chain process and an ERP system process reference model. In addition to its theoretical contributions, the results can also be practically applied to projects involving the selection and implementation of ERP systems.

  16. Thick-film voltammetric pH-sensors with internal indicator and reference species

    DEFF Research Database (Denmark)

    Musa, Arnaud Emmanuel; Alonso-Lomillo, María Asunción; del Campo, Francisco Javier

    2012-01-01

    , low cost and ease of fabrication. More importantly, as opposed to conventional voltammetric systems where the height of the voltammetric peaks is taken into account to quantify the amount of a species of interest, here, the difference between the peak potential of the indicator species and the peak...... potential of the reference species is used. Thus, this measurement principle makes the electrochemical system presented here less dependent on the potential of the reference electrode (RE), as is often the case in other electrochemical systems. The developed system displays very promising performances...

  17. Uranium reference materials

    International Nuclear Information System (INIS)

    Donivan, S.; Chessmore, R.

    1987-07-01

    The Technical Measurements Center has prepared uranium mill tailings reference materials for use by remedial action contractors and cognizant federal and state agencies. Four materials were prepared with varying concentrations of radionuclides, using three tailings materials and a river-bottom soil diluent. All materials were ground, dried, and blended thoroughly to ensure homogeneity. The analyses on which the recommended values for nuclides in the reference materials are based were performed, using independent methods, by the UNC Geotech (UNC) Chemistry Laboratory, Grand Junction, Colorado, and by C.W. Sill (Sill), Idaho National Engineering Laboratory, Idaho Falls, Idaho. Several statistical tests were performed on the analytical data to characterize the reference materials. Results of these tests reveal that the four reference materials are homogeneous and that no large systematic bias exists between the analytical methods used by Sill and those used by TMC. The average values for radionuclides of the two data sets, representing an unbiased estimate, were used as the recommended values for concentrations of nuclides in the reference materials. The recommended concentrations of radionuclides in the four reference materials are provided. Use of these reference materials will aid in providing uniform standardization among measurements made by remedial action contractors. 11 refs., 9 tabs

  18. Robust stator resistance identification of an IM drive using model reference adaptive system

    International Nuclear Information System (INIS)

    Madadi Kojabadi, Hossein; Abarzadeh, Mostafa; Aghaei Farouji, Said

    2013-01-01

    Highlights: ► We estimate the stator resistance and rotor speed of the IM. ► We proposed a new quantity to estimate the speed and stator resistance of IM. ► The proposed algorithm is robust to rotor resistance variations. ► We estimate the IM speed and stator resistance simultaneously to avoid speed error. - Abstract: Model reference adaptive system (MRAS) based robust stator resistance estimator for sensorless induction motor (IM) drive is proposed. The MRAS is formed with a semi-active power quantity. The proposed identification method can be achieved with on-line tuning of the stator resistance with robustness against rotor resistance variations. Stable and efficient estimation of IM speed at low region will be guaranteed by simultaneous identification of IM speed and stator resistance. The stability of proposed stator resistance estimator is checked through Popov’s hyperstability theorem. Simulation and experimental results are given to highlight the feasibility, the simplicity, and the robustness of the proposed method.

  19. Three-Dimensional Imaging by Self-Reference Single-Channel Digital Incoherent Holography

    Science.gov (United States)

    Rosen, Joseph; Kelner, Roy

    2016-01-01

    Digital holography offers a reliable and fast method to image a three-dimensional scene from a single perspective. This article reviews recent developments of self-reference single-channel incoherent hologram recorders. Hologram recorders in which both interfering beams, commonly referred to as the signal and the reference beams, originate from the same observed objects are considered as self-reference systems. Moreover, the hologram recorders reviewed herein are configured in a setup of a single channel interferometer. This unique configuration is achieved through the use of one or more spatial light modulators. PMID:28757811

  20. Reference Assessment

    Science.gov (United States)

    Bivens-Tatum, Wayne

    2006-01-01

    This article presents interesting articles that explore several different areas of reference assessment, including practical case studies and theoretical articles that address a range of issues such as librarian behavior, patron satisfaction, virtual reference, or evaluation design. They include: (1) "Evaluating the Quality of a Chat Service"…

  1. Micro-arcsecond Celestial Reference Frames: definition and realization — Impact of the recent IAU Resolutions

    International Nuclear Information System (INIS)

    Capitaine, Nicole

    2012-01-01

    The adoption of the International Celestial Reference System (ICRS), based on Very Long Baseline Interferometry (VLBI) observations of extragalactic radiosources by the International Astronomical Union (IAU) since 1998 January 1, opened a new era for astronomy. The ICRS and the corresponding frame, the International Celestial Reference Frame (ICRF), replaced the Fundamental Catalog (FK5) based on positions and proper motions of bright stars, with the Hipparcos catalog being adopted as the primary realization of the ICRS in optical wavelengths. According to its definition, the ICRS is such that the barycentric directions of distant extragalactic objects show no global rotation with respect to these objects; this provides a quasi-inertial reference for measuring the positions and angular motions of the celestial objects. Other resolutions on reference systems were passed by the IAU in 2000 and 2006 and endorsed by the International Union of Geodesy and Geophysics (IUGG) in 2003 and 2007, respectively. These especially concern the definition and realization of the astronomical reference systems in the framework of general relativity and transformations between them. First, the IAU 2000 resolutions refined the concepts and definition of the astronomical reference systems and parameters for Earth's rotation, and adopted the IAU 2000 precession-nutation. Then, the IAU 2006 resolutions adopted a new precession model that is consistent with dynamical theories; they also addressed definition, terminology or orientation issues relative to reference systems and time scales that needed to be specified after the adoption of the IAU 2000 resolutions. An additional IUGG 2007 resolution defined the International Terrestrial Reference System (ITRS) so that it strictly complies with the IAU recommendations. Finally, the IAU 2009 resolutions adopted a new system of astronomical constants and an improved realization of the ICRF. These fundamental changes have led to significant

  2. Consistent realization of Celestial and Terrestrial Reference Frames

    Science.gov (United States)

    Kwak, Younghee; Bloßfeld, Mathis; Schmid, Ralf; Angermann, Detlef; Gerstl, Michael; Seitz, Manuela

    2018-03-01

    The Celestial Reference System (CRS) is currently realized only by Very Long Baseline Interferometry (VLBI) because it is the space geodetic technique that enables observations in that frame. In contrast, the Terrestrial Reference System (TRS) is realized by means of the combination of four space geodetic techniques: Global Navigation Satellite System (GNSS), VLBI, Satellite Laser Ranging (SLR), and Doppler Orbitography and Radiopositioning Integrated by Satellite. The Earth orientation parameters (EOP) are the link between the two types of systems, CRS and TRS. The EOP series of the International Earth Rotation and Reference Systems Service were combined of specifically selected series from various analysis centers. Other EOP series were generated by a simultaneous estimation together with the TRF while the CRF was fixed. Those computation approaches entail inherent inconsistencies between TRF, EOP, and CRF, also because the input data sets are different. A combined normal equation (NEQ) system, which consists of all the parameters, i.e., TRF, EOP, and CRF, would overcome such an inconsistency. In this paper, we simultaneously estimate TRF, EOP, and CRF from an inter-technique combined NEQ using the latest GNSS, VLBI, and SLR data (2005-2015). The results show that the selection of local ties is most critical to the TRF. The combination of pole coordinates is beneficial for the CRF, whereas the combination of Δ UT1 results in clear rotations of the estimated CRF. However, the standard deviations of the EOP and the CRF improve by the inter-technique combination which indicates the benefits of a common estimation of all parameters. It became evident that the common determination of TRF, EOP, and CRF systematically influences future ICRF computations at the level of several μas. Moreover, the CRF is influenced by up to 50 μas if the station coordinates and EOP are dominated by the satellite techniques.

  3. Radon-daughter chamber instrumentation system reference manual

    International Nuclear Information System (INIS)

    Showalter, R.; Johnson, L.

    1985-01-01

    The radon-daughter chamber instrumentation system collects environmental data from the radon-daughter chamber. These data are then recorded on a Tandberg system tape cartridge and transmitted to the HP-1000 computer for processing. Generators which inject radon and condensation nuclei into the chamber are also included with the instrumentation system

  4. Multi-media communication system: Upper layers in the OSI reference model

    NARCIS (Netherlands)

    Zafirovic-Vukotic, M.; Niemegeers, I.G.M.M.

    1992-01-01

    The structuring, services, and major protocol functions that are required in the upper layers of the OSI reference model in order to support end-to-end multimedia communication, assuming a simple transport service, are examined. It is assumed that variable-bit-rate (VBR) coding techniques will be

  5. Electrothermal frequency references in standard CMOS

    CERN Document Server

    Kashmiri, S Mahdi

    2013-01-01

    This book describes an alternative method of accurate on-chip frequency generation in standard CMOS IC processes. This method exploits the thermal-diffusivity of silicon, the rate at which heat diffuses through a silicon substrate.  This is the first book describing thermal-diffusivity-based frequency references, including the complete theoretical methodology supported by practical realizations that prove the feasibility of the method.  Coverage also includes several circuit and system-level solutions for the analog electronic circuit design challenges faced.   ·         Surveys the state-of-the-art in all-silicon frequency references; ·         Examines the thermal properties of silicon as a solution for the challenge of on-chip accurate frequency generation; ·         Uses simplified modeling approaches that allow an electronics engineer easily to simulate the electrothermal elements; ·         Follows a top-down methodology in circuit design, in which system-level des...

  6. Reference Mission Version 3.0 Addendum to the Human Exploration of Mars: The Reference Mission of the NASA Mars Exploration Study Team. Addendum; 3.0

    Science.gov (United States)

    Drake, Bret G. (Editor)

    1998-01-01

    This Addendum to the Mars Reference Mission was developed as a companion document to the NASA Special Publication 6107, "Human Exploration of Mars: The Reference Mission of the NASA Mars Exploration Study Team." It summarizes changes and updates to the Mars Reference Missions that were developed by the Exploration Office since the final draft of SP 6107 was printed in early 1999. The Reference Mission is a tool used by the exploration community to compare and evaluate approaches to mission and system concepts that could be used for human missions to Mars. It is intended to identify and clarify system drivers, significant sources of cost, performance, risk, and schedule variation. Several alternative scenarios, employing different technical approaches to solving mission and technology challenges, are discussed in this Addendum. Comparing alternative approaches provides the basis for continual improvement to technology investment plan and a general understanding of future human missions to Mars. The Addendum represents a snapshot of work in progress in support of planning for future human exploration missions through May 1998.

  7. Development of the regional EPR and PACS sharing system on the infrastructure of cloud computing technology controlled by patient identifier cross reference manager.

    Science.gov (United States)

    Kondoh, Hiroshi; Teramoto, Kei; Kawai, Tatsurou; Mochida, Maki; Nishimura, Motohiro

    2013-01-01

    A Newly developed Oshidori-Net2, providing medical professionals with remote access to electronic patient record systems (EPR) and PACSs of four hospitals, of different venders, using cloud computing technology and patient identifier cross reference manager. The operation was started from April 2012. The patients moved to other hospital were applied. Objective is to show the merit and demerit of the new system.

  8. Valores de referência para carboxiemoglobina Reference values for carboxyhemoglobin

    Directory of Open Access Journals (Sweden)

    Maria Elisa P. B. de Siqueira

    1997-12-01

    Full Text Available INTRODUÇÃO: Os valores de referência de indicadores biológicos são utilizados como parâmetros para interpretação de resultados de valores obtidos em indivíduos expostos ocupacionalmente aos agentes químicos. O Grupo Brasileiro para Estabelecimento dos Valores de Referência tem se dedicado a estas determinações objetivando estabelecer valores de referência para os diferentes bioindicadores em diversas regiões do País. Determinaram-se os valores de referência para a carboxiemoglobina (COHb no Sul de Minas Gerais. MATERIAL E MÉTODO: A COHb foi analisada pelo método espectrofométrico, otimizado no laboratório de análises toxicológicas. Em todas as amostras também foram realizadas análises de alguns parâmetros bioquímicos e hematológicos para atestar o estado de saúde da população, constituída de 200 voluntários não-fumantes e não-expostos, por motivo profissional, ao monóxido de carbono. Cada indivíduo respondeu um questionário para levantamento de dados relevantes à interpretação dos resultados. Os valores de referência foram expressos em termos da média ± desvio-padrão, intervalo de confiança 95% e valor de referência superior. A distribuição estatística dos resultados obtidos foi realizada para possibilitar sua comparação com grupos de trabalhadores, preferentemente à avaliação individual. RESULTADOS E CONCLUSÕES: O valor médio ± desvio-padrão para a carboxiemoglobina foi de 1,0 % ± 0,75; o intervalo de confiança 95%, entre 0,9 e 1,1 % e o valor de referência superior, de 2,5%. Através do teste t de Student (p INTRODUCTION: The reference values (RV of biological indicators are used in the interpretation of the results of such indicators in individuals occupationally exposed to chemical agents. The Brazilian Group for the Establishment of Reference Values has worked on these definitions for the purpose of establishing RVs for several bioindicators in various regions of the country. In

  9. Operators Manual and Technical Reference for the Z-Beamlet Phase Modulation Failsafe System: Version 1.

    Energy Technology Data Exchange (ETDEWEB)

    Armstrong, Darrell J.

    2014-09-01

    The need for pulse energies exceeding 4 kJ and pulse lengths [?] 2 ns in Sandia's Z-Beamlet laser (ZBL) requires that the single-frequency spectrum of its fiber-laser master oscillator be converted to a phase modulated spectrum with a modulation in dex [?] 5. Because accidental injection of single-frequency light into ZBL could result i n damage to optical materials from transverse stimulated Brillouin scattering, the presence of phase modulated (PM) light must be monitored by a reliable failsafe system that can stop a las er shot within of a few 10's of ns following a failure of the PM system. This requirement is met by combining optical heterodyne detection with high-speed electronics to indicate the pres ence or absence of phase modulated light. The transition time for the failsafe signal resultin g from a sudden failure using this technique is approximately 35 ns. This is sufficiently short to safely stop a single-frequency laser pulse from leaving ZBL's regenerative amplifier with a n approximately 35 ns margin of safety. This manual and technical reference contains detai led instructions for daily use of the PM failsafe system and provides enough additional informat ion for its maintenance and repair.

  10. [Application of traditional Chinese medicine reference standards in quality control of Chinese herbal pieces].

    Science.gov (United States)

    Lu, Tu-Lin; Li, Jin-Ci; Yu, Jiang-Yong; Cai, Bao-Chang; Mao, Chun-Qin; Yin, Fang-Zhou

    2014-01-01

    Traditional Chinese medicine (TCM) reference standards plays an important role in the quality control of Chinese herbal pieces. This paper overviewed the development of TCM reference standards. By analyzing the 2010 edition of Chinese pharmacopoeia, the application of TCM reference standards in the quality control of Chinese herbal pieces was summarized, and the problems exiting in the system were put forward. In the process of improving the quality control level of Chinese herbal pieces, various kinds of advanced methods and technology should be used to research the characteristic reference standards of Chinese herbal pieces, more and more reasonable reference standards should be introduced in the quality control system of Chinese herbal pieces. This article discussed the solutions in the aspect of TCM reference standards, and future development of quality control on Chinese herbal pieces is prospected.

  11. Mechanical engineer's reference book

    CERN Document Server

    Parrish, A

    1973-01-01

    Mechanical Engineer's Reference Book: 11th Edition presents a comprehensive examination of the use of Systéme International d' Unités (SI) metrication. It discusses the effectiveness of such a system when used in the field of engineering. It addresses the basic concepts involved in thermodynamics and heat transfer. Some of the topics covered in the book are the metallurgy of iron and steel; screw threads and fasteners; hole basis and shaft basis fits; an introduction to geometrical tolerancing; mechanical working of steel; high strength alloy steels; advantages of making components as castings

  12. Four-year prospective study of STAPH-IDENT system and conventional method for reference identification of Staphylococcus, Stomatococcus, and Micrococcus spp..

    Science.gov (United States)

    Rhoden, D L; Miller, J M

    1995-01-01

    A 4-year prospective study compared the accuracy of the STAPH-IDENT system (bioMérieux Vitek, Inc., Hazelwood, Mo.) with that of the reference procedure of the Centers for Disease Control and Prevention for the identification of Staphylococcus species, Stomatococcus mucilaginosus, and Micrococcus species. The study compared the results from 1,106 cultures (500 eye cultures, 217 strains submitted for reference identification, and 389 known stock strains) representing 21 species of the family Micrococcaceae. The overall agreement of genus and species identifications was 81.1%. The percent agreement for the five most common clinical isolates was as follows: Staphylococcus epidermidis, 97.1% (517 isolates); Staphylococcus hominis, 82.5% (57 isolates); Staphylococcus aureus, 77.2% (162 isolates); Staphylococcus haemolyticus, 75.8% (61 isolates); and Staphylococcus warneri, 64.1% (39 isolates). The lowest percent agreement was with Staphylococcus cohnii (11.1%; (9 isolates). Of the 217 isolates sent to the Centers for Disease Control and Prevention for identification, 60.4% (131) were correctly identified by the STAPH-IDENT system. Of these, S. epidermidis accounted for 23.9%, S. aureus accounted for 15.6%, S. warneri accounted for 6.9%, Staphylococcus lugdunensis accounted for 6.5%, S. haemolyticus accounted for 5.5%, and S. hominis accounted for 4.1%. The STAPH-IDENT system did not perform adequately when dealing with commonly encountered organisms and is unsuitable for identifying uncommon isolates. PMID:7699074

  13. Modal-space reference-model-tracking fuzzy control of earthquake excited structures

    Science.gov (United States)

    Park, Kwan-Soon; Ok, Seung-Yong

    2015-01-01

    This paper describes an adaptive modal-space reference-model-tracking fuzzy control technique for the vibration control of earthquake-excited structures. In the proposed approach, the fuzzy logic is introduced to update optimal control force so that the controlled structural response can track the desired response of a reference model. For easy and practical implementation, the reference model is constructed by assigning the target damping ratios to the first few dominant modes in modal space. The numerical simulation results demonstrate that the proposed approach successfully achieves not only the adaptive fault-tolerant control system against partial actuator failures but also the robust performance against the variations of the uncertain system properties by redistributing the feedback control forces to the available actuators.

  14. Auditory Warnings, Signal-Referent Relations, and Natural Indicators: Re-Thinking Theory and Application

    Science.gov (United States)

    Petocz, Agnes; Keller, Peter E.; Stevens, Catherine J.

    2008-01-01

    In auditory warning design the idea of the strength of the association between sound and referent has been pivotal. Research has proceeded via constructing classification systems of signal-referent associations and then testing predictions about ease of learning of different levels of signal-referent relation strength across and within different…

  15. [Establishing biological reference intervals of alanine transaminase for clinical laboratory stored database].

    Science.gov (United States)

    Guo, Wei; Song, Binbin; Shen, Junfei; Wu, Jiong; Zhang, Chunyan; Wang, Beili; Pan, Baishen

    2015-08-25

    To establish an indirect reference interval based on the test results of alanine aminotransferase stored in a laboratory information system. All alanine aminotransferase results were included for outpatients and physical examinations that were stored in the laboratory information system of Zhongshan Hospital during 2014. The original data were transformed using a Box-Cox transformation to obtain an approximate normal distribution. Outliers were identified and omitted using the Chauvenet and Tukey methods. The indirect reference intervals were obtained by simultaneously applying nonparametric and Hoffmann methods. The reference change value was selected to determine the statistical significance of the observed differences between the calculated and published reference intervals. The indirect reference intervals for alanine aminotransferase of all groups were 12 to 41 U/L (male, outpatient), 12 to 48 U/L (male, physical examination), 9 to 32 U/L (female, outpatient), and 8 to 35 U/L (female, physical examination), respectively. The absolute differences when compared with the direct results were all smaller than the reference change value of alanine aminotransferase. The Box-Cox transformation combined with the Hoffmann and Tukey methods is a simple and reliable technique that should be promoted and used by clinical laboratories.

  16. Preliminary measurements of the establishment of a quality control programme for the activimeter calibration reference system

    International Nuclear Information System (INIS)

    Martins, Elaine W.; Potiens, Maria da Penha A.

    2009-01-01

    The nuclear medicine techniques efficiency and safety depends on, beside other factors, a quality control programme, mainly regards to the nuclides activimeter utilization. The Calibration Laboratory of IPEN uses as a work standard, a tertiary standard system Capintec, calibrated at the Accredited Dosimetry Calibration Laboratory of the Medical radiation Research Center - University of Wisconsin. In this work, as preliminary measurements to establish a quality control programme for the activimeter calibration procedures, initially the repeatability and reproducibility (long term stability) tests were performed using a sealed check source of 133 Ba. Later on, to complete this quality control programme other check sources ( 137 Cs, 57 Co, 60 Co) will be used to perform the same tests. A series of 80 experiments of 10 measurements each has been carried out. The reference system showed a good behaviour to the repeatability test, considering the tolerance limits of 5%. The percent deviations of all tested sources in the activity measurements were lower 1% to 133 Ba. (author)

  17. Direct model reference adaptive control with application to flexible robots

    Science.gov (United States)

    Steinvorth, Rodrigo; Kaufman, Howard; Neat, Gregory W.

    1992-01-01

    A modification to a direct command generator tracker-based model reference adaptive control (MRAC) system is suggested in this paper. This modification incorporates a feedforward into the reference model's output as well as the plant's output. Its purpose is to eliminate the bounded model following error present in steady state when previous MRAC systems were used. The algorithm was evaluated using the dynamics for a single-link flexible-joint arm. The results of these simulations show a response with zero steady state model following error. These results encourage further use of MRAC for various types of nonlinear plants.

  18. IAEA biological reference materials

    International Nuclear Information System (INIS)

    Parr, R.M.; Schelenz, R.; Ballestra, S.

    1988-01-01

    The Analytical Quality Control Services programme of the IAEA encompasses a wide variety of intercomparisons and reference materials. This paper reviews only those aspects of the subject having to do with biological reference materials. The 1988 programme foresees 13 new intercomparison exercises, one for major, minor and trace elements, five for radionuclides, and seven for stable isotopes. Twenty-two natural matrix biological reference materials are available: twelve for major, minor and trace elements, six for radionuclides, and four for chlorinated hydrocarbons. Seven new intercomparisons and reference materials are in preparation or under active consideration. Guidelines on the correct use of reference materials are being prepared for publication in 1989 in consultation with other major international producers and users of biological reference materials. The IAEA database on available reference materials is being updated and expanded in scope, and a new publication is planned for 1989. (orig.)

  19. Standard Reference Tables -

    Data.gov (United States)

    Department of Transportation — The Standard Reference Tables (SRT) provide consistent reference data for the various applications that support Flight Standards Service (AFS) business processes and...

  20. Establishing a business process reference model for Universities

    DEFF Research Database (Denmark)

    Svensson, Carsten; Hvolby, Hans-Henrik

    2012-01-01

    Modern universities are by any standard complex organizations that, from an IT perspective, present a number of unique challenges. This paper will propose establishing a business process reference framework. The benefit to the users would be a better understanding of the system landscape, business......) have gained popularity among organizations in both the private and public sectors. We speculate that this success can be replicated in a university setting. Furthermore the paper will outline how the research group suggests moving ahead with the research which will lead to a reference model....

  1. Importance of quality aspects of GP care among ethnic minorities: role of cultural attitudes, language and healthcare system of reference.

    Science.gov (United States)

    Lamkaddem, Majda; Spreeuwenberg, Peter M; Devillé, Walter L; Foets, Marleen M; Groenewegen, Peter P

    2012-02-01

    This study examines the mechanisms responsible for ethnic differences in perceived quality of care in The Netherlands. The specific role of cultural attitudes, language proficiency, and the health system in the country of origin was examined, taking socio-demographic characteristics into account. Interview data of 1339 respondents of Moroccan, Turkish, Surinamese and Antillean origin were combined with interview data of Dutch respondents (n = 405) and of Western immigrants (n = 102) in The Netherlands and of a random sample of Dutch privately or publicly insured persons (n = 9675). Data collection took place within the Second Dutch National Survey of General Practice (DNSGP-2, 2001). Items from the QUality Of care Through the patient's Eyes (QUOTE) questionnaire were used to measure expectations, as well as items from the QUOTE-Mi (adapted version for migrant groups). Items on normative orientations were used to measure cultural attitudes. In contrast to our hypothesis, respondents with more egalitarian/modern attitudes attached less importance to quality aspects related to access and quality. Tests on the role of the health system of reference were generally conclusive, showing that respondents accustomed to (parts of) another system have different expectations regarding several aspects of general practitioner healthcare quality, e.g. access to specialist care. Besides socio-demographic characteristics, culture influences patients' expectations regarding general practitioner care quality. However, the role of culture can be more clearly ascribed to the characteristics of the health system which is held as the reference than to the general attitudes on normative orientations.

  2. Evaluation of the PREVI® Isola automated seeder system compared to reference manual inoculation for antibiotic susceptibility testing by the disk diffusion method.

    Science.gov (United States)

    Le Page, S; van Belkum, A; Fulchiron, C; Huguet, R; Raoult, D; Rolain, J-M

    2015-09-01

    The disk diffusion (DD) method remains the most popular manual technique for antibiotic susceptibility testing (AST) in clinical microbiology laboratories. This is because of its simplicity, reproducibility, and limited cost compared to (automated) microdilution systems, which are usually less sensitive at detecting certain important mechanisms of resistance. Here, we evaluate the PREVI® Isola automated seeder system using a new protocol for spreading bacterial suspensions (eight deposits of calibrated inocula of bacteria, followed by two rounds of rotation) in comparison with manual DD reference testing on a large series of clinical and reference strains. The average time required for seeding one agar plate for DD with this new protocol was 51 s per plate, i.e., 70 agar plates/h. Reproducibility and repeatability was assessed on three reference and three randomly chosen clinical strains, as usually requested by the European Committee on Antimicrobial Susceptibility Testing (EUCAST), and was excellent compared to the manual method. The standard deviations of zones of growth inhibition showed no statistical discrimination. The correlation between the two methods, assessed using 294 clinical isolates and a panel of six antibiotics (n = 3,528 zones of growth inhibition measured), was excellent, with a correlation coefficient of 0.977. The new PREVI® Isola protocol adapted for DD had a sensitivity of 99 % and a specificity of 100 % compared to the manual technique for interpreting DD as recommended by the EUCAST.

  3. Oscillating red giants in eclipsing binary systems: empirical reference value for asteroseismic scaling relation

    Science.gov (United States)

    Themeßl, N.; Hekker, S.; Southworth, J.; Beck, P. G.; Pavlovski, K.; Tkachenko, A.; Angelou, G. C.; Ball, W. H.; Barban, C.; Corsaro, E.; Elsworth, Y.; Handberg, R.; Kallinger, T.

    2018-05-01

    The internal structures and properties of oscillating red-giant stars can be accurately inferred through their global oscillation modes (asteroseismology). Based on 1460 days of Kepler observations we perform a thorough asteroseismic study to probe the stellar parameters and evolutionary stages of three red giants in eclipsing binary systems. We present the first detailed analysis of individual oscillation modes of the red-giant components of KIC 8410637, KIC 5640750 and KIC 9540226. We obtain estimates of their asteroseismic masses, radii, mean densities and logarithmic surface gravities by using the asteroseismic scaling relations as well as grid-based modelling. As these red giants are in double-lined eclipsing binaries, it is possible to derive their independent dynamical masses and radii from the orbital solution and compare it with the seismically inferred values. For KIC 5640750 we compute the first spectroscopic orbit based on both components of this system. We use high-resolution spectroscopic data and light curves of the three systems to determine up-to-date values of the dynamical stellar parameters. With our comprehensive set of stellar parameters we explore consistencies between binary analysis and asteroseismic methods, and test the reliability of the well-known scaling relations. For the three red giants under study, we find agreement between dynamical and asteroseismic stellar parameters in cases where the asteroseismic methods account for metallicity, temperature and mass dependence as well as surface effects. We are able to attain agreement from the scaling laws in all three systems if we use Δνref, emp = 130.8 ± 0.9 μHz instead of the usual solar reference value.

  4. 7 CFR 300.4 - Reference Manual B.

    Science.gov (United States)

    2010-01-01

    ..., 2001, by the National Seed Health System (NSHS), has been approved for incorporation by reference in 7... inspection at the APHIS Library, U.S. Department of Agriculture, 4700 River Road, Riverdale, MD or at the... the APHIS Web site at http://www.aphis.usda.gov/ppq/pim/accreditation. ...

  5. Reference Intervals of Common Clinical Chemistry Analytes for Adults in Hong Kong.

    Science.gov (United States)

    Lo, Y C; Armbruster, David A

    2012-04-01

    Defining reference intervals is a major challenge because of the difficulty in recruiting volunteers to participate and testing samples from a significant number of healthy reference individuals. Historical literature citation intervals are often suboptimal because they're be based on obsolete methods and/or only a small number of poorly defined reference samples. Blood donors in Hong Kong gave permission for additional blood to be collected for reference interval testing. The samples were tested for twenty-five routine analytes on the Abbott ARCHITECT clinical chemistry system. Results were analyzed using the Rhoads EP evaluator software program, which is based on the CLSI/IFCC C28-A guideline, and defines the reference interval as the 95% central range. Method specific reference intervals were established for twenty-five common clinical chemistry analytes for a Chinese ethnic population. The intervals were defined for each gender separately and for genders combined. Gender specific or combined gender intervals were adapted as appropriate for each analyte. A large number of healthy, apparently normal blood donors from a local ethnic population were tested to provide current reference intervals for a new clinical chemistry system. Intervals were determined following an accepted international guideline. Laboratories using the same or similar methodologies may adapt these intervals if deemed validated and deemed suitable for their patient population. Laboratories using different methodologies may be able to successfully adapt the intervals for their facilities using the reference interval transference technique based on a method comparison study.

  6. Reference trajectory tracking for a multi-DOF robot arm

    Directory of Open Access Journals (Sweden)

    Krasňanský Róbert

    2015-12-01

    Full Text Available This paper presents the problem of tracking the generated reference trajectory by the simulation model of a multi-DOF robot arm. The kinematic transformation between task space and joint configuration coordinates is nonlinear and configuration dependent. To obtain the solution of the forward kinematics problem, the homogeneous transformation matrix is used. A solution to the inverse kinematics is a vector of joint configuration coordinates calculated using of pseudoinverse Jacobian technique. These coordinates correspond to a set of task space coordinates. The algorithm is presented which uses iterative solution and is simplified by considering stepper motors in robot arm joints. The reference trajectory in Cartesian coordinate system is generated on-line by the signal generator previously developed in MS Excel. Dynamic Data Exchange communication protocol allows sharing data with Matlab-Simulink. These data represent the reference tracking trajectory of the end effector. Matlab-Simulink software is used to calculate the representative joint rotations. The proposed algorithm is demonstrated experimentally on the model of 7-DOF robot arm system.

  7. Tv & video engineer's reference book

    CERN Document Server

    Jackson, K G

    1991-01-01

    TV & Video Engineer's Reference Book presents an extensive examination of the basic television standards and broadcasting spectrum. It discusses the fundamental concepts in analogue and digital circuit theory. It addresses studies in the engineering mathematics, formulas, and calculations. Some of the topics covered in the book are the conductors and insulators, passive components, alternating current circuits; broadcast transmission; radio frequency propagation; electron optics in cathode ray tube; color encoding and decoding systems; television transmitters; and remote supervision of unatten

  8. Universal electronic-cigarette test: physiochemical characterization of reference e-liquid

    Directory of Open Access Journals (Sweden)

    Jeffrey J. Kim

    2017-02-01

    The efforts described here to create a standardized e-liquid Reference Material aim to provide unbiased and robust testing parameters that may be useful for researchers, the industry and government agencies. Additionally, the reference e-liquid could open a channel of conversation among different laboratories by providing the means of independent verification and validation while establishing a system of transparency and reproducibility in materials and methods.

  9. 78 FR 18415 - Connected Vehicle Reference Implementation Architecture Workshop; Notice of Public Meeting

    Science.gov (United States)

    2013-03-26

    ... DEPARTMENT OF TRANSPORTATION Connected Vehicle Reference Implementation Architecture Workshop...) Intelligent Transportation System Joint Program Office (ITS JPO) will host a free Connected Vehicle Reference... manufacturing, developing, deploying, operating, or maintaining the connected [[Page 18416

  10. Model Reference Adaptive Control of the Air Flow Rate of Centrifugal Compressor Using State Space Method

    International Nuclear Information System (INIS)

    Han, Jaeyoung; Jung, Mooncheong; Yu, Sangseok; Yi, Sun

    2016-01-01

    In this study, a model reference adaptive controller is developed to regulate the outlet air flow rate of centrifugal compressor for automotive supercharger. The centrifugal compressor is developed using the analytical based method to predict the transient behavior of operating and the designed model is validated with experimental data to confirm the system accuracy. The model reference adaptive control structure consists of a compressor model and a MRAC(model reference adaptive control) mechanism. The feedback control do not robust with variation of system parameter but the applied adaptive control is robust even if the system parameter is changed. As a result, the MRAC was regulated to reference air flow rate. Also MRAC was found to be more robust control compared with the feedback control even if the system parameter is changed.

  11. Model Reference Adaptive Control of the Air Flow Rate of Centrifugal Compressor Using State Space Method

    Energy Technology Data Exchange (ETDEWEB)

    Han, Jaeyoung; Jung, Mooncheong; Yu, Sangseok [Chungnam Nat’l Univ., Daejeon (Korea, Republic of); Yi, Sun [North Carolina A and T State Univ., Raleigh (United States)

    2016-08-15

    In this study, a model reference adaptive controller is developed to regulate the outlet air flow rate of centrifugal compressor for automotive supercharger. The centrifugal compressor is developed using the analytical based method to predict the transient behavior of operating and the designed model is validated with experimental data to confirm the system accuracy. The model reference adaptive control structure consists of a compressor model and a MRAC(model reference adaptive control) mechanism. The feedback control do not robust with variation of system parameter but the applied adaptive control is robust even if the system parameter is changed. As a result, the MRAC was regulated to reference air flow rate. Also MRAC was found to be more robust control compared with the feedback control even if the system parameter is changed.

  12. The GCOS Reference Upper-Air Network (GRUAN)

    Science.gov (United States)

    Vömel, H.; Berger, F. H.; Immler, F. J.; Seidel, D.; Thorne, P.

    2009-04-01

    While the global upper-air observing network has provided useful observations for operational weather forecasting for decades, its measurements lack the accuracy and long-term continuity needed for understanding climate change. Consequently, the scientific community faces uncertainty on such key issues as the trends of temperature in the upper troposphere and stratosphere or the variability and trends of stratospheric water vapour. To address these shortcomings, and to ensure that future climate records will be more useful than the records to date, the Global Climate Observing System (GCOS) program initiated the GCOS Reference Upper Air Network (GRUAN). GRUAN will be a network of about 30-40 observatories with a representative sampling of geographic regions and surface types. These stations will provide upper-air reference observations of the essential climate variables, i.e. temperature, geopotential, humidity, wind, radiation and cloud properties using specialized radiosondes and complementary remote sensing profiling instrumentation. Long-term stability, quality assurance / quality control, and a detailed assessment of measurement uncertainties will be the key aspects of GRUAN observations. The network will not be globally complete but will serve to constrain and adjust data from more spatially comprehensive global observing systems including satellites and the current radiosonde networks. This paper outlines the scientific rationale for GRUAN, its role in the Global Earth Observation System of Systems, network requirements and likely instrumentation, management structure, current status and future plans.

  13. Current control of PMSM based on maximum torque control reference frame

    Science.gov (United States)

    Ohnuma, Takumi

    2017-07-01

    This study presents a new method of current controls of PMSMs (Permanent Magnet Synchronous Motors) based on a maximum torque control reference frame, which is suitable for high-performance controls of the PMSMs. As the issues of environment and energy increase seriously, PMSMs, one of the AC motors, are becoming popular because of their high-efficiency and high-torque density in various applications, such as electric vehicles, trains, industrial machines, and home appliances. To use the PMSMs efficiently, a proper current control of the PMSMs is necessary. In general, a rotational coordinate system synchronizing with the rotor is used for the current control of PMSMs. In the rotating reference frame, the current control is easier because the currents on the rotating reference frame can be expressed as a direct current in the controller. On the other hand, the torque characteristics of PMSMs are non-linear and complex; the PMSMs are efficient and high-density though. Therefore, a complicated control system is required to involve the relation between the torque and the current, even though the rotating reference frame is adopted. The maximum torque control reference frame provides a simpler way to control efficiently the currents taking the torque characteristics of the PMSMs into consideration.

  14. Direct calibration of GC/MS systems using SRM (Standard Reference Material) gas cylinders. Project report, January 1984-August 1985

    International Nuclear Information System (INIS)

    Byrd, G.D.; Richie, K.L.; Sniegoski, L.T.; White, E.

    1985-10-01

    A cryogenic trapping system has been developed for use in calibrating GC/MS systems for the analysis of volatile organic compounds. This system provides for direct Standard Reference Material (SRM) traceability on data generated on gaseous samples. The cryogenic trap is a coil of stainless steel tubing immersed in a cryogen to trap and preconcentrate organic species present in a gaseous sample. The trap also contains a heated injection port for the addition of isotopically labeled compounds for use in isotope dilution measurements. The first part of this research is concerned with the development of IDMS as an independent method for the quantification of analytes in gaseous samples to be used as standards. Results are presented for the determination of bromobenzene in nitrogen at nominal concentrations of 1 and 25 ppb. In the second part of the research, a calibration curve method was developed for using these standards in auditing the performance of GC/MS systems

  15. Internal validation of the DNAscan/ANDE™ Rapid DNA Analysis™ platform and its associated PowerPlex® 16 high content DNA biochip cassette for use as an expert system with reference buccal swabs.

    Science.gov (United States)

    Moreno, Lilliana I; Brown, Alice L; Callaghan, Thomas F

    2017-07-01

    Rapid DNA platforms are fully integrated systems capable of producing and analyzing short tandem repeat (STR) profiles from reference sample buccal swabs in less than two hours. The technology requires minimal user interaction and experience making it possible for high quality profiles to be generated outside an accredited laboratory. The automated production of point of collection reference STR profiles could eliminate the time delay for shipment and analysis of arrestee samples at centralized laboratories. Furthermore, point of collection analysis would allow searching against profiles from unsolved crimes during the normal booking process once the infrastructure to immediately search the Combined DNA Index System (CODIS) database from the booking station is established. The DNAscan/ANDE™ Rapid DNA Analysis™ System developed by Network Biosystems was evaluated for robustness and reliability in the production of high quality reference STR profiles for database enrollment and searching applications. A total of 193 reference samples were assessed for concordance of the CODIS 13 loci. Studies to evaluate contamination, reproducibility, precision, stutter, peak height ratio, noise and sensitivity were also performed. The system proved to be robust, consistent and dependable. Results indicated an overall success rate of 75% for the 13 CODIS core loci and more importantly no incorrect calls were identified. The DNAscan/ANDE™ could be confidently used without human interaction in both laboratory and non-laboratory settings to generate reference profiles. Published by Elsevier B.V.

  16. A Fiducial Reference Stie for Satellite Altimetry in Crete, Greece

    Science.gov (United States)

    Mertikas, Stelios; Donlon, Craig; Mavrocordatos, Constantin; Bojkov, Bojan; Femenias, Pierre; Parrinello, Tommaso; Picot, Nicolas; Desjonqueres, Jean-Damien; Andersen, Ole Baltazar

    2016-08-01

    With the advent of diverse satellite altimeters and variant measuring techniques, it has become mature in the scientific community, that an absolute reference Cal/Val site is regularly maintained to define, monitor, control the responses of any altimetric system.This work sets the ground for the establishment of a Fiducial Reference Site for ESA satellite altimetry in Gavdos and West Crete, Greece. It will consistently and reliably determine (a) absolute altimeter biases and their drifts; (b) relative bias among diverse missions; but also (c) continuously and independently connect different missions, on a common and reliable reference and also to SI-traceable measurements. Results from this fiducial reference site will be based on historic Cal/Val site measurement records, and will be the yardstick for building up capacity for monitoring climate change. This will be achieved by defining and assessing any satellite altimeter measurements to known, controlled and absolute reference signals with different techniques, processes and instrumentation.

  17. A systematic review of reference pricing: implications for US prescription drug spending.

    Science.gov (United States)

    Lee, Joy Li-Yueh; Fischer, Micahel A; Shrank, William H; Polinski, Jennifer M; Choudhry, Niteesh K

    2012-11-01

    Given rising pharmaceutical expenditures and the widespread use of reference pricing as a costcontainment instrument abroad, we systematically reviewed the evidence evaluating reference pricing policies. We performed a structured electronic search of peer-reviewed journals for studies published before that reported on the effects of reference pricing policies on medication use, payer and patient spending, and resource consumption. Our search yielded 16 studies describing 9 reference-pricing policies from 6 countries. Reference-pricing policies led to decreases in drug prices and increases in utilization of targeted medications, while also reducing payer and patient expenditures. In addition, these policies did not lead to increased use of medical services, such as physician office visits and hospitalization. These results suggest that reference pricing may be an attractive policy strategy for the US healthcare system.

  18. Task demands and individual variation in referring expressions

    NARCIS (Netherlands)

    Baltaretu, Adriana-Alexandra; Castro Ferreira, Thiago

    Aiming to improve the human-likeness of natural language generation systems, this study investigates different sources of variation that might influence the production of referring expressions (REs), namely the effect of task demands and inter- intra- individual variation. We collected REs using a

  19. TRENDS: A flight test relational database user's guide and reference manual

    Science.gov (United States)

    Bondi, M. J.; Bjorkman, W. S.; Cross, J. L.

    1994-01-01

    This report is designed to be a user's guide and reference manual for users intending to access rotocraft test data via TRENDS, the relational database system which was developed as a tool for the aeronautical engineer with no programming background. This report has been written to assist novice and experienced TRENDS users. TRENDS is a complete system for retrieving, searching, and analyzing both numerical and narrative data, and for displaying time history and statistical data in graphical and numerical formats. This manual provides a 'guided tour' and a 'user's guide' for the new and intermediate-skilled users. Examples for the use of each menu item within TRENDS is provided in the Menu Reference section of the manual, including full coverage for TIMEHIST, one of the key tools. This manual is written around the XV-15 Tilt Rotor database, but does include an appendix on the UH-60 Blackhawk database. This user's guide and reference manual establishes a referrable source for the research community and augments NASA TM-101025, TRENDS: The Aeronautical Post-Test, Database Management System, Jan. 1990, written by the same authors.

  20. STL pocket reference

    CERN Document Server

    Lischner, Ray

    2003-01-01

    The STL Pocket Reference describes the functions, classes, and templates in that part of the C++ standard library often referred to as the Standard Template Library (STL). The STL encompasses containers, iterators, algorithms, and function objects, which collectively represent one of the most important and widely used subsets of standard library functionality. The C++ standard library, even the subset known as the STL, is vast. It's next to impossible to work with the STL without some sort of reference at your side to remind you of template parameters, function invocations, return types--ind

  1. VBE reference framework

    NARCIS (Netherlands)

    Afsarmanesh, H.; Camarinha-Matos, L.M.; Ermilova, E.; Camarinha-Matos, L.M.; Afsarmanesh, H.; Ollus, M.

    2008-01-01

    Defining a comprehensive and generic "reference framework" for Virtual organizations Breeding Environments (VBEs), addressing all their features and characteristics, is challenging. While the definition and modeling of VBEs has become more formalized during the last five years, "reference models"

  2. GTX Reference Vehicle Structural Verification Methods and Weight Summary

    Science.gov (United States)

    Hunter, J. E.; McCurdy, D. R.; Dunn, P. W.

    2002-01-01

    The design of a single-stage-to-orbit air breathing propulsion system requires the simultaneous development of a reference launch vehicle in order to achieve the optimal mission performance. Accordingly, for the GTX study a 300-lb payload reference vehicle was preliminarily sized to a gross liftoff weight (GLOW) of 238,000 lb. A finite element model of the integrated vehicle/propulsion system was subjected to the trajectory environment and subsequently optimized for structural efficiency. This study involved the development of aerodynamic loads mapped to finite element models of the integrated system in order to assess vehicle margins of safety. Commercially available analysis codes were used in the process along with some internally developed spreadsheets and FORTRAN codes specific to the GTX geometry for mapping of thermal and pressure loads. A mass fraction of 0.20 for the integrated system dry weight has been the driver for a vehicle design consisting of state-of-the-art composite materials in order to meet the rigid weight requirements. This paper summarizes the methodology used for preliminary analyses and presents the current status of the weight optimization for the structural components of the integrated system.

  3. The importance of reference materials in doping-control analysis.

    Science.gov (United States)

    Mackay, Lindsey G; Kazlauskas, Rymantas

    2011-08-01

    Currently a large range of pure substance reference materials are available for calibration of doping-control methods. These materials enable traceability to the International System of Units (SI) for the results generated by World Anti-Doping Agency (WADA)-accredited laboratories. Only a small number of prohibited substances have threshold limits for which quantification is highly important. For these analytes only the highest quality reference materials that are available should be used. Many prohibited substances have no threshold limits and reference materials provide essential identity confirmation. For these reference materials the correct identity is critical and the methods used to assess identity in these cases should be critically evaluated. There is still a lack of certified matrix reference materials to support many aspects of doping analysis. However, in key areas a range of urine matrix materials have been produced for substances with threshold limits, for example 19-norandrosterone and testosterone/epitestosterone (T/E) ratio. These matrix-certified reference materials (CRMs) are an excellent independent means of checking method recovery and bias and will typically be used in method validation and then regularly as quality-control checks. They can be particularly important in the analysis of samples close to threshold limits, in which measurement accuracy becomes critical. Some reference materials for isotope ratio mass spectrometry (IRMS) analysis are available and a matrix material certified for steroid delta values is currently under production. In other new areas, for example the Athlete Biological Passport, peptide hormone testing, designer steroids, and gene doping, reference material needs still need to be thoroughly assessed and prioritised.

  4. Hg0 and HgCl2 Reference Gas Standards: ?NIST Traceability ...

    Science.gov (United States)

    EPA and NIST have collaborated to establish the necessary procedures for establishing the required NIST traceability of commercially-provided Hg0 and HgCl2 reference generators. This presentation will discuss the approach of a joint EPA/NIST study to accurately quantify the true concentrations of Hg0 and HgCl2 reference gases produced from high quality, NIST-traceable, commercial Hg0 and HgCl2 generators. This presentation will also discuss the availability of HCl and Hg0 compressed reference gas standards as a result of EPA's recently approved Alternative Methods 114 and 118. Gaseous elemental mercury (Hg0) and oxidized mercury (HgCl2) reference standards are integral to the use of mercury continuous emissions monitoring systems (Hg CEMS) for regulatory compliance emissions monitoring. However, a quantitative disparity of approximately 7-10% has been observed between commercial Hg0 and HgCl2 reference gases which currently limits the use of (HgCl2) reference gas standards. Resolving this disparity would enable the expanded use of (HgCl2) reference gas standards for regulatory compliance purposes.

  5. Improving Reference Service: The Case for Using a Continuous Quality Improvement Method.

    Science.gov (United States)

    Aluri, Rao

    1993-01-01

    Discusses the evaluation of library reference service; examines problems with past evaluations, including the lack of long-term planning and a systems perspective; and suggests a method for continuously monitoring and improving reference service using quality improvement tools such as checklists, cause and effect diagrams, Pareto charts, and…

  6. WECC Variable Generation Planning Reference Book

    Energy Technology Data Exchange (ETDEWEB)

    Makarov, Yuri V.; Du, Pengwei; Etingov, Pavel V.; Ma, Jian; Vyakaranam, Bharat

    2013-05-14

    This planning reference book is a document reflecting a Western Electricity Coordination Council (WECC) effort to put together multiple sources of information and provide a clear, systemic, comprehensive outline of the problems, both existing and anticipated; their impacts on the system; currently used and proposed solutions by the industry and research community; planning practices; new technologies, equipment, and standards; and expected future trends. This living (periodically updated) document could help WECC and other practicing engineers, especially the younger generation of engineers joining the workforce, to get familiar with a large variety of information related to the integration of variable resources into the WECC system, bypassing in part the need for time-consuming information gathering and learning processes from more experienced engineers or from the literature.

  7. User Preferences in Reference Services: Virtual Reference and Academic Libraries

    Science.gov (United States)

    Cummings, Joel; Cummings, Lara; Frederiksen, Linda

    2007-01-01

    This study examines the use of chat in an academic library's user population and where virtual reference services might fit within the spectrum of public services offered by academic libraries. Using questionnaires, this research demonstrates that many within the academic community are open to the idea of chat-based reference or using chat for…

  8. Python essential reference

    CERN Document Server

    Beazley, David M

    2009-01-01

    Python Essential Reference is the definitive reference guide to the Python programming language — the one authoritative handbook that reliably untangles and explains both the core Python language and the most essential parts of the Python library. Designed for the professional programmer, the book is concise, to the point, and highly accessible. It also includes detailed information on the Python library and many advanced subjects that is not available in either the official Python documentation or any other single reference source. Thoroughly updated to reflect the significant new programming language features and library modules that have been introduced in Python 2.6 and Python 3, the fourth edition of Python Essential Reference is the definitive guide for programmers who need to modernize existing Python code or who are planning an eventual migration to Python 3. Programmers starting a new Python project will find detailed coverage of contemporary Python programming idioms.

  9. Systems analysis programs for hands-on integrated reliability evaluations (SAPHIRE) Version 5.0. Fault tree, event tree, and piping ampersand instrumentation diagram (FEP) editors reference manual: Volume 7

    International Nuclear Information System (INIS)

    McKay, M.K.; Skinner, N.L.; Wood, S.T.

    1994-07-01

    The Systems Analysis Programs for Hands-on Integrated Reliability Evaluations (SAPHIRE) refers to a set of several microcomputer programs that were developed to create and analyze probabilistic risk assessments (PRAs), primarily for nuclear power plants. The Fault Tree, Event Tree, and Piping and Instrumentation Diagram (FEP) editors allow the user to graphically build and edit fault trees, and event trees, and piping and instrumentation diagrams (P and IDs). The software is designed to enable the independent use of the graphical-based editors found in the Integrated Reliability and Risk Assessment System (IRRAS). FEP is comprised of three separate editors (Fault Tree, Event Tree, and Piping and Instrumentation Diagram) and a utility module. This reference manual provides a screen-by-screen guide of the entire FEP System

  10. CSS Pocket Reference

    CERN Document Server

    Meyer, Eric

    2011-01-01

    When you're working with CSS and need a quick answer, CSS Pocket Reference delivers. This handy, concise book provides all of the essential information you need to implement CSS on the fly. Ideal for intermediate to advanced web designers and developers, the 4th edition is revised and updated for CSS3, the latest version of the Cascading Style Sheet specification. Along with a complete alphabetical reference to CSS3 selectors and properties, you'll also find a short introduction to the key concepts of CSS. Based on Cascading Style Sheets: The Definitive Guide, this reference is an easy-to-us

  11. Mechanical Energy Change in Inertial Reference Frames

    Science.gov (United States)

    Ghanbari, Saeed

    2016-01-01

    The mechanical energy change of a system in an inertial frame of reference equals work done by the total nonconservative force in the same frame. This relation is covariant under the Galilean transformations from inertial frame S to S', where S' moves with constant velocity relative to S. In the presence of nonconservative forces, such as normal…

  12. Using Instant Messaging for Online Reference Service

    Science.gov (United States)

    Forster, Shirley

    2006-01-01

    Many libraries are using co-browsing chat products to provide reference services to their patrons, whilst their patrons are online and using the internet. The concept of such an online service is highly desirable, but many libraries are concerned that they will never be able to afford such a system. This may have changed: Instant Messaging (IM)…

  13. Exogenous reference gene normalization for real-time reverse transcription-polymerase chain reaction analysis under dynamic endogenous transcription.

    Science.gov (United States)

    Johnston, Stephen; Gallaher, Zachary; Czaja, Krzysztof

    2012-05-15

    Quantitative real-time reverse transcription-polymerase chain reaction (qPCR) is widely used to investigate transcriptional changes following experimental manipulations to the nervous system. Despite the widespread utilization of qPCR, the interpretation of results is marred by the lack of a suitable reference gene due to the dynamic nature of endogenous transcription. To address this inherent deficiency, we investigated the use of an exogenous spike-in mRNA, luciferase, as an internal reference gene for the 2(-∆∆Ct) normalization method. To induce dynamic transcription, we systemically administered capsaicin, a neurotoxin selective for C-type sensory neurons expressing the TRPV-1 receptor, to adult male Sprague-Dawley rats. We later isolated nodose ganglia for qPCR analysis with the reference being either exogenous luciferase mRNA or the commonly used endogenous reference β-III tubulin. The exogenous luciferase mRNA reference clearly demonstrated the dynamic expression of the endogenous reference. Furthermore, variability of the endogenous reference would lead to misinterpretation of other genes of interest. In conclusion, traditional reference genes are often unstable under physiologically normal situations, and certainly unstable following the damage to the nervous system. The use of exogenous spike-in reference provides a consistent and easily implemented alternative for the analysis of qPCR data.

  14. A Reference Model for Distribution Grid Control in the 21st Century

    Energy Technology Data Exchange (ETDEWEB)

    Taft, Jeffrey D. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); De Martini, Paul [California Inst. of Technology (CalTech), Pasadena, CA (United States); Kristov, Lorenzo [California Independent System Operator, Folsom, CA (United States)

    2015-07-01

    Intensive changes in the structure of the grid due to the penetration of new technologies, coupled with changing societal needs are outpacing the capabilities of traditional grid control systems. The gap is widening at an accelerating rate with the biggest impacts occurring at the distribution level due to the widespread adoption of diverse distribution-connected energy resources (DER) . This paper outlines the emerging distribution grid control environment, defines the new distribution control problem, and provides a distribution control reference model. The reference model offers a schematic representation of the problem domain to inform development of system architecture and control solutions for the high-DER electric system.

  15. The impact of different definitions and reference groups on the prevalence of cognitive impairment: a study in postmenopausal breast cancer patients before the start of adjuvant systemic therapy.

    Science.gov (United States)

    Schilder, Christina M; Seynaeve, Caroline; Linn, Sabine C; Boogerd, Willem; Gundy, Chad M; Beex, Louk V; van Dam, Frits S; Schagen, Sanne B

    2010-04-01

    Several prospective studies into the effects of adjuvant systemic therapy on cognitive functioning suggest that a proportion of breast cancer patients show cognitive deficits already before the start of systemic therapy. Owing to, among others, methodological inconsistency, studies report different rates of this pre-treatment cognitive impairment. We examined the impact of four different criteria of cognitive impairment and two types of reference groups (a study-specific healthy reference group versus published normative data) on the prevalence of cognitive impairment. Two hundred and five postmenopausal breast cancer patients underwent a battery of neuropsychological tests before the start of endocrine therapy, 124 healthy subjects underwent the same tests. Proportions of cognitive impaired patients were calculated for each of four criteria for cognitive impairment, using (1) study-specific healthy controls and (2) published norms of healthy controls as reference groups. The prevalence of cognitive impairment varied greatly with the strictness of the criterion, as expected, but also was dependent on the reference group used. Cognitive impairment, relative to published norms, ranged from 1% for the strictest to 36.6% for the less strict criterion, cognitive impairment relative to study-specific healthy controls, ranged from 13.7 to 45.4% for the same criteria. This study highlights contrasting proportions of cognitive impairment by using different criteria for cognitive impairment and different reference groups. (Dis)advantages of the methods using a criterion for cognitive impairment, and of the use of published norms versus a study-specific reference group are discussed. Copyright 2009 John Wiley & Sons, Ltd.

  16. SYSTEMATIC ERROR REDUCTION: NON-TILTED REFERENCE BEAM METHOD FOR LONG TRACE PROFILER

    International Nuclear Information System (INIS)

    QIAN, S.; QIAN, K.; HONG, Y.; SENG, L.; HO, T.; TAKACS, P.

    2007-01-01

    Systematic error in the Long Trace Profiler (LTP) has become the major error source as measurement accuracy enters the nanoradian and nanometer regime. Great efforts have been made to reduce the systematic error at a number of synchrotron radiation laboratories around the world. Generally, the LTP reference beam has to be tilted away from the optical axis in order to avoid fringe overlap between the sample and reference beams. However, a tilted reference beam will result in considerable systematic error due to optical system imperfections, which is difficult to correct. Six methods of implementing a non-tilted reference beam in the LTP are introduced: (1) application of an external precision angle device to measure and remove slide pitch error without a reference beam, (2) independent slide pitch test by use of not tilted reference beam, (3) non-tilted reference test combined with tilted sample, (4) penta-prism scanning mode without a reference beam correction, (5) non-tilted reference using a second optical head, and (6) alternate switching of data acquisition between the sample and reference beams. With a non-tilted reference method, the measurement accuracy can be improved significantly. Some measurement results are presented. Systematic error in the sample beam arm is not addressed in this paper and should be treated separately

  17. Decolonisation and Teaching Law in Africa with Special Reference ...

    African Journals Online (AJOL)

    MJM Venter

    2017-10-26

    Oct 26, 2017 ... decolonisation of law to how law is taught, with special reference to living ...... 44. Ponnusamy and Pandurangan Hand Book on University System 13. ... Ehrlich E Fundamental Principles of the Sociology of Law (Harvard.

  18. Effect of the waste exclusion distance on the postclosure performance of a reference disposal system

    International Nuclear Information System (INIS)

    Goodwin, B.W.; Hajas, W.C.; Melnyk, T.W.; Kitson, C.I.

    1995-07-01

    The concept for disposal of Canada's nuclear fuel waste involves the isolation of the waste in corrosion-resistant containers placed in a sealed vault at a depth of 500 to 1000 metres in plutonic rock of the Canadian Shield. The technical feasibility of this concept, and its impact on the environment and human health, are summarized in an Environmental Impact Statement (EIS). The EIS is supported by nine primary references, one of which describes the postclosure assessment of the concept. The postclosure assessment is concerned with the long-term performance and behaviour of the disposal system, starting from the time the disposal facility is closed and extending far into the future. The discussions presented in the EIS and the postclosure assessment are based on a case study of a hypothetical disposal system with specific design features and host rock characteristics. The design features are founded on a conceptual engineering study and the rock characteristics are derived from geological studies of a field research area. In the case study, the long-term performance of the hypothetical disposal system was strongly dependent on a design parameter called the waste exclusion distance. This distance is defined as the minimum length of low-permeability sparsely fractured rock between the waste-emplacement part of the hypothetical vault and a nearby conductive fracture zone in the host rock. In this report, we examine trends in estimates of radiological impact as a function of the waste exclusion distance. (author). 18 refs., 14 figs

  19. Estimating the Reference Incremental Cost-Effectiveness Ratio for the Australian Health System.

    Science.gov (United States)

    Edney, Laura Catherine; Haji Ali Afzali, Hossein; Cheng, Terence Chai; Karnon, Jonathan

    2018-02-01

    Spending on new healthcare technologies increases net population health when the benefits of a new technology are greater than their opportunity costs-the benefits of the best alternative use of the additional resources required to fund a new technology. The objective of this study was to estimate the expected incremental cost per quality-adjusted life-year (QALY) gained of increased government health expenditure as an empirical estimate of the average opportunity costs of decisions to fund new health technologies. The estimated incremental cost-effectiveness ratio (ICER) is proposed as a reference ICER to inform value-based decision making in Australia. Empirical top-down approaches were used to estimate the QALY effects of government health expenditure with respect to reduced mortality and morbidity. Instrumental variable two-stage least-squares regression was used to estimate the elasticity of mortality-related QALY losses to a marginal change in government health expenditure. Regression analysis of longitudinal survey data representative of the general population was used to isolate the effects of increased government health expenditure on morbidity-related, QALY gains. Clinical judgement informed the duration of health-related quality-of-life improvement from the annual increase in government health expenditure. The base-case reference ICER was estimated at AUD28,033 per QALY gained. Parametric uncertainty associated with the estimation of mortality- and morbidity-related QALYs generated a 95% confidence interval AUD20,758-37,667. Recent public summary documents suggest new technologies with ICERs above AUD40,000 per QALY gained are recommended for public funding. The empirical reference ICER reported in this article suggests more QALYs could be gained if resources were allocated to other forms of health spending.

  20. Endogenizing Prospect Theory's Reference Point

    OpenAIRE

    Ulrich Schmidt; Horst Zank

    2010-01-01

    In previous models of (cumulative) prospect theory reference-dependence of preferences is imposed beforehand and the location of the reference point is exogenously determined. This note provides a foundation of prospect theory, where reference-dependence is derived from preference conditions and a unique reference point arises endogenously.

  1. Accuracy assessment of NOAA's daily reference evapotranspiration maps for the Texas High Plains

    Science.gov (United States)

    The National Oceanic and Atmospheric Administration (NOAA) provides daily reference ET for the continental U.S. using climatic data from North American Land Data Assimilation System (NLDAS). This data provides large scale spatial representation for reference ET, which is essential for regional scal...

  2. The derivation of the general form of kinematics with the universal reference system

    Science.gov (United States)

    Szostek, Karol; Szostek, Roman

    2018-03-01

    In the article, the whole class of time and position transformations was derived. These transformations were derived based on the analysis of the Michelson-Morley experiment and its improved version, that is the Kennedy-Thorndike experiment. It is possible to derive a different kinematics of bodies based on each of these transformations. In this way, we demonstrated that the Special Theory of Relativity is not the only theory explaining the results of experiments with light. There is the whole continuum of the theories of kinematics of bodies which correctly explain the Michelson-Morley experiment and other experiments in which the velocity of light is measured. Based on the derived transformations, we derive the general formula for the velocity of light in vacuum measured in any inertial reference system. We explain why the Michelson-Morley and Kennedy-Thorndike experiments could not detect the ether. We present and discuss three examples of specific transformations. Finally, we explain the phenomenon of anisotropy of the cosmic microwave background radiation by means of the presented theory. The theory derived in this work is called the Special Theory of Ether - with any transverse contraction. The entire article contains only original research conducted by its authors.

  3. The citation with reference and the citation as a reference

    Directory of Open Access Journals (Sweden)

    Rafael Antonio Cunha Perrone

    2011-12-01

    Full Text Available O ensaio objetiva estabelecer paralelos entre a citação acadêmica e a citação utilizada como referência, para a produção das obras ou projetos de arquitetura. O artigo discute o uso de figuras paradigmáticas ou significativas, transladadas ou amalgamadas nas obras de arquitetura, a partir do entendimento da citação como dado argumentativo e qualitativo. Investiga algumas de suas assimetrias e congruências em sua utilização na linguagem escrita, como transcrição direta ou como fonte interpretativa, reelaborada e incorporada como argumento em outro texto. Pondera que no ensinar, estudar e fazer arquitetura é preciso saber citar com referência, para poder citar como referência.

  4. Reference and counter electrode positions affect electrochemical characterization of bioanodes in different bioelectrochemical systems

    KAUST Repository

    Zhang, Fang

    2014-06-16

    The placement of the reference electrode (RE) in various bioelectrochemical systems is often varied to accommodate different reactor configurations. While the effect of the RE placement is well understood from a strictly electrochemistry perspective, there are impacts on exoelectrogenic biofilms in engineered systems that have not been adequately addressed. Varying distances between the working electrode (WE) and the RE, or the RE and the counter electrode (CE) in microbial fuel cells (MFCs) can alter bioanode characteristics. With well-spaced anode and cathode distances in an MFC, increasing the distance between the RE and anode (WE) altered bioanode cyclic voltammograms (CVs) due to the uncompensated ohmic drop. Electrochemical impedance spectra (EIS) also changed with RE distances, resulting in a calculated increase in anode resistance that varied between 17 and 31Ω (-0.2V). While WE potentials could be corrected with ohmic drop compensation during the CV tests, they could not be automatically corrected by the potentiostat in the EIS tests. The electrochemical characteristics of bioanodes were altered by their acclimation to different anode potentials that resulted from varying the distance between the RE and the CE (cathode). These differences were true changes in biofilm characteristics because the CVs were electrochemically independent of conditions resulting from changing CE to RE distances. Placing the RE outside of the current path enabled accurate bioanode characterization using CVs and EIS due to negligible ohmic resistances (0.4Ω). It is therefore concluded for bioelectrochemical systems that when possible, the RE should be placed outside the current path and near the WE, as this will result in more accurate representation of bioanode characteristics. © 2014 Wiley Periodicals, Inc.

  5. Marketing Reference Services.

    Science.gov (United States)

    Norman, O. Gene

    1995-01-01

    Relates the marketing concept to library reference services. Highlights include a review of the literature and an overview of marketing, including research, the marketing mix, strategic plan, marketing plan, and marketing audit. Marketing principles are applied to reference services through the marketing mix elements of product, price, place, and…

  6. Strengthening your ties to referring physicians through RIS/PACS integration.

    Science.gov (United States)

    Worthy, Susan; Rounds, Karla C; Soloway, Connie B

    2003-01-01

    Many imaging centers are turning to technology solutions to increase refering physician satisfaction, implementing such enhancements as automated report distribution, picture archiving and communications system (PACS), radiology information systems (RIS), and web-based results access. However, without seamless integration, these technology investments don't address the challenge at its core: convenient and reliable, two-way communication and interaction with referring physicians. In an integrated RIS/PACS solution, patient tracking in the RIS and PACS study status are logged and available to users. The time of the patient's registration at the imaging center, the exam start and completion time, the patient's departure time from the imaging center, and results status are all tracked and logged. An integrated RIS/PACS solution provides additional support to the radiologist, a critical factor that can improve the turnaround time of results to referring physicians. The RIS/PACS enhances the interpretation by providing the patient's history, which gives the radiologist additional insight and decreases the likelihood of missing a diagnostic element. In a tightly integrated RIS/PACS solution, results information is more complete. Physicians can view reports with associated images selected by the radiologist. They will also have full order information and complete imaging history including prior reports and images. Referring physicians can access and view images and exam notes at the same time that the radiologist is interpreting the exam. Without the benefit of an integrated RIS/PACS system, the referring physician would have to wait for the signed transcription to be released. In a seamlessly integrated solution, film-tracking modules within the RIS are fused with digital imaging workflow in the PACS. Users can see at a glance if a historical exam is available on film and benefit when a complete study history--both film-based and digital--is presented with the current

  7. LINQ Pocket Reference

    CERN Document Server

    Albahari, Joseph

    2008-01-01

    Ready to take advantage of LINQ with C# 3.0? This guide has the detail you need to grasp Microsoft's new querying technology, and concise explanations to help you learn it quickly. And once you begin to apply LINQ, the book serves as an on-the-job reference when you need immediate reminders. All the examples in the LINQ Pocket Reference are preloaded into LINQPad, the highly praised utility that lets you work with LINQ interactively. Created by the authors and free to download, LINQPad will not only help you learn LINQ, it will have you thinking in LINQ. This reference explains: LINQ's ke

  8. A reference Pelton turbine - High speed visualization in the rotating frame

    Science.gov (United States)

    Solemslie, Bjørn W.; Dahlhaug, Ole G.

    2016-11-01

    To enable a detailed study the flow mechanisms effecting the flow within the reference Pelton runner designed at the Waterpower Laboratory (NTNLT) a flow visualization system has been developed. The system enables high speed filming of the hydraulic surface of a single bucket in the rotating frame of reference. It is built with an angular borescopes adapter entering the turbine along the rotational axis and a borescope embedded within a bucket. A stationary high speed camera located outside the turbine housing has been connected to the optical arrangement by a non-contact coupling. The view point of the system includes the whole hydraulic surface of one half of a bucket. The system has been designed to minimize the amount of vibrations and to ensure that the vibrations felt by the borescope are the same as those affecting the camera. The preliminary results captured with the system are promising and enable a detailed study of the flow within the turbine.

  9. Visual Basic 2012 programmer's reference

    CERN Document Server

    Stephens, Rod

    2012-01-01

    The comprehensive guide to Visual Basic 2012 Microsoft Visual Basic (VB) is the most popular programming language in the world, with millions of lines of code used in businesses and applications of all types and sizes. In this edition of the bestselling Wrox guide, Visual Basic expert Rod Stephens offers novice and experienced developers a comprehensive tutorial and reference to Visual Basic 2012. This latest edition introduces major changes to the Visual Studio development platform, including support for developing mobile applications that can take advantage of the Windows 8 operating system

  10. Adaptation of penelope Monte Carlo code system to the absorbed dose metrology: characterization of high energy photon beams and calculations of reference dosimeter correction factors

    International Nuclear Information System (INIS)

    Mazurier, J.

    1999-01-01

    This thesis has been performed in the framework of national reference setting-up for absorbed dose in water and high energy photon beam provided with the SATURNE-43 medical accelerator of the BNM-LPRI (acronym for National Bureau of Metrology and Primary standard laboratory of ionising radiation). The aim of this work has been to develop and validate different user codes, based on PENELOPE Monte Carlo code system, to determine the photon beam characteristics and calculate the correction factors of reference dosimeters such as Fricke dosimeters and graphite calorimeter. In the first step, the developed user codes have permitted the influence study of different components constituting the irradiation head. Variance reduction techniques have been used to reduce the calculation time. The phase space has been calculated for 6, 12 and 25 MV at the output surface level of the accelerator head, then used for calculating energy spectra and dose distributions in the reference water phantom. Results obtained have been compared with experimental measurements. The second step has been devoted to develop an user code allowing calculation correction factors associated with both BNM-LPRI's graphite and Fricke dosimeters thanks to a correlated sampling method starting with energy spectra obtained in the first step. Then the calculated correction factors have been compared with experimental and calculated results obtained with the Monte Carlo EGS4 code system. The good agreement, between experimental and calculated results, leads to validate simulations performed with the PENELOPE code system. (author)

  11. Fabricating defensible reference standards for the NDA lab

    Energy Technology Data Exchange (ETDEWEB)

    Ceo, R.N.; May, P.K. [Oak Ridge Y-12 Plant, TN (United States)

    1997-11-01

    Nondestructive analysis (NDA) is performed at the Oak Ridge Y-12 Plant in support of the enriched uranium operations. Process materials are analyzed using gamma ray- and neutron-based instruments including segmented gamma scanners, solution assay systems, and an active well coincidence counter. Process wastes are also discarded based on results of these measurements. Good analytical practice, as well as applicable regulations, mandates that these analytical methods be calibrated using reference materials traceable to the national standards base. Reference standards for NDA instruments are not commercially available owing to the large quantities of special nuclear materials involved. Instead, representative materials are selected from each process stream, then thoroughly characterized by methods that are traceable to the national standards base. This paper discusses the process materials to be analyzed, reference materials selected for calibrating each NDA instrument, and details of their characterization and fabrication into working calibrations standards. Example calibration curves are also presented. 4 figs.

  12. Fabricating defensible reference standards for the NDA lab

    International Nuclear Information System (INIS)

    Ceo, R.N.; May, P.K.

    1997-01-01

    Nondestructive analysis (NDA) is performed at the Oak Ridge Y-12 Plant in support of the enriched uranium operations. Process materials are analyzed using gamma ray- and neutron-based instruments including segmented gamma scanners, solution assay systems, and an active well coincidence counter. Process wastes are also discarded based on results of these measurements. Good analytical practice, as well as applicable regulations, mandates that these analytical methods be calibrated using reference materials traceable to the national standards base. Reference standards for NDA instruments are not commercially available owing to the large quantities of special nuclear materials involved. Instead, representative materials are selected from each process stream, then thoroughly characterized by methods that are traceable to the national standards base. This paper discusses the process materials to be analyzed, reference materials selected for calibrating each NDA instrument, and details of their characterization and fabrication into working calibrations standards. Example calibration curves are also presented. 4 figs

  13. Demonstrated Wavelength Portability of Raman Reference Data for Explosives and Chemical Detection

    Directory of Open Access Journals (Sweden)

    Timothy J. Johnson

    2012-01-01

    Full Text Available As Raman spectroscopy continues to evolve, questions arise as to the portability of Raman data: dispersive versus Fourier transform, wavelength calibration, intensity calibration, and in particular the frequency of the excitation laser. While concerns about fluorescence arise in the visible or ultraviolet, most modern (portable systems use near-infrared excitation lasers, and many of these are relatively close in wavelength. We have investigated the possibility of porting reference data sets from one NIR wavelength system to another: We have constructed a reference library consisting of 145 spectra, including 20 explosives, as well as sundry other compounds and materials using a 1064 nm spectrometer. These data were used as a reference library to evaluate the same 145 compounds whose experimental spectra were recorded using a second 785 nm spectrometer. In 128 cases of 145 (or 88.3% including 20/20 for the explosives, the compounds were correctly identified with a mean “hit score” of 954 of 1000. Adding in criteria for when to declare a correct match versus when to declare uncertainty, the approach was able to correctly categorize 134 out of 145 spectra, giving a 92.4% accuracy. For the few that were incorrectly identified, either the matched spectra were spectroscopically similar to the target or the 785 nm signal was degraded due to fluorescence. The results indicate that imported data recorded at a different NIR wavelength can be successfully used as reference libraries, but key issues must be addressed: the reference data must be of equal or higher resolution than the resolution of the current sensor, the systems require rigorous wavelength calibration, and wavelength-dependent intensity response should be accounted for in the different systems.

  14. Reference Japanese man

    International Nuclear Information System (INIS)

    Tanaka, Giichiro

    1985-01-01

    To make real and accurate dose assessment method so far, it is necessitated to provide ''Reference Japanese Man'' based on anotomical, physiological and biochemical data of Japanese people instead of the Reference Man presented in ICRP Publications 23 and 30. This review describes present status of researched for the purpose of establishing of Reference Japanese Man. The Reference Japanese Man is defined as a male or female adult who lives in Japan with a Japanese life-style and food custom. His stature and body weight, and the other data was decided as mean values of male or female people of Japan. As for food custom, Japanese people take significantly smaller amount of meat and milk products than Western people, while larger intake amount of cereals and marine products such as fish or seaweeds. Weight of organs is a principal factor for internal dose assessment and mean values for living Japanese adult has been investigated and the value employable for dose assessment for organs and tissues are shown. To employ these values of Reference Japanese Man, it should be taken into account of age. Metabolic parameters should also be considered. Iodine metabolism in Japanese is quite different from that of Western people. The above-mentioned data are now tentatively employing in modification of table of MIRD method and others. (Takagi, S.)

  15. Reference in human and non-human primate communication: What does it take to refer?

    Science.gov (United States)

    Sievers, Christine; Gruber, Thibaud

    2016-07-01

    The concept of functional reference has been used to isolate potentially referential vocal signals in animal communication. However, its relatedness to the phenomenon of reference in human language has recently been brought into question. While some researchers have suggested abandoning the concept of functional reference altogether, others advocate a revision of its definition to include contextual cues that play a role in signal production and perception. Empirical and theoretical work on functional reference has also put much emphasis on how the receiver understands the referential signal. However, reference, as defined in the linguistic literature, is an action of the producer, and therefore, any definition describing reference in non-human animals must also focus on the producer. To successfully determine whether a signal is used to refer, we suggest an approach from the field of pragmatics, taking a closer look at specific situations of signal production, specifically at the factors that influence the production of a signal by an individual. We define the concept of signaller's reference to identify intentional acts of reference produced by a signaller independently of the communicative modality, and illustrate it with a case study of the hoo vocalizations produced by wild chimpanzees during travel. This novel framework introduces an intentional approach to referentiality. It may therefore permit a closer comparison of human and non-human animal referential behaviour and underlying cognitive processes, allowing us to identify what may have emerged solely in the human lineage.

  16. Reference class forecasting

    DEFF Research Database (Denmark)

    Flyvbjerg, Bent

    optimisme og misinformation. RCF bygger på teorier, som vandt Daniel Kahneman Nobelprisen i økonomi i 2002. RCF estimerer budgettet for et givet projekt på grundlag af de faktiske udfald for budgetterne i en reference-klasse af projekter. RCF udføres i tre trin: 1. Identifikation af en relevant reference...

  17. Critical care providers refer to information tools less during communication tasks after a critical care clinical information system introduction.

    Science.gov (United States)

    Ballermann, Mark; Shaw, Nicola T; Mayes, Damon C; Gibney, R T Noel

    2011-01-01

    Electronic documentation methods may assist critical care providers with information management tasks in Intensive Care Units (ICUs). We conducted a quasi-experimental observational study to investigate patterns of information tool use by ICU physicians, nurses, and respiratory therapists during verbal communication tasks. Critical care providers used tools less at 3 months after the CCIS introduction. At 12 months, care providers referred to paper and permanent records, especially during shift changes. The results suggest potential areas of improvement for clinical information systems in assisting critical care providers in ensuring informational continuity around their patients.

  18. Selection of spatial reference frames depends on task's demands

    Directory of Open Access Journals (Sweden)

    Greeshma Sharma

    2016-12-01

    Full Text Available Spatial reference frames (SRF are the means of representing spatial relations or locations either in an egocentric coordinate system (centred on navigator or in an allocentric coordinate system (Centred on object. It is necessary to understand when and how spatial representation switches between allocentric and egocentric reference frames in context to spatial tasks. The objective of this study was to explore if the elementary spatial representation does exist, whether it would remain consistent or change under the influence of a task's demand. Also, we explored how the SRF would assist if the environment is enriched with landmarks, having multiple routes for wayfinding. The results showed that the switching of SRF depends not only on the default representation but also on a task's demand. They also demonstrated that participants who were using allocentric representation performed better in the presence of landmarks.

  19. Android quick APIs reference

    CERN Document Server

    Cinar, Onur

    2015-01-01

    The Android Quick APIs Reference is a condensed code and APIs reference for the new Google Android 5.0 SDK. It presents the essential Android APIs in a well-organized format that can be used as a handy reference. You won't find any technical jargon, bloated samples, drawn out history lessons, or witty stories in this book. What you will find is a software development kit and APIs reference that is concise, to the point and highly accessible. The book is packed with useful information and is a must-have for any mobile or Android app developer or programmer. In the Android Quick APIs Refe

  20. Robot operating system (ROS) the complete reference

    CERN Document Server

    The objective of this book is to provide the reader with a comprehensive coverage on the Robot Operating Systems (ROS) and latest related systems, which is currently considered as the main development framework for robotics applications. The book includes twenty-seven chapters organized into eight parts. Part 1 presents the basics and foundations of ROS. In Part 2, four chapters deal with navigation, motion and planning. Part 3 provides four examples of service and experimental robots. Part 4 deals with real-world deployment of applications. Part 5 presents signal-processing tools for perception and sensing. Part 6 provides software engineering methodologies to design complex software with ROS. Simulations frameworks are presented in Part 7. Finally, Part 8 presents advanced tools and frameworks for ROS including multi-master extension, network introspection, controllers and cognitive systems. This book will be a valuable companion for ROS users and developers to learn more ROS capabilities and features.   ...

  1. Structural lesions detected by magnetic resonance imaging in the spine of patients with spondyloarthritis - definitions, assessment system, and reference image set

    DEFF Research Database (Denmark)

    Østergaard, Mikkel; Maksymowych, Walter P; Pedersen, Susanne J

    2009-01-01

    are assessed at each vertebral endplate at all 23 spinal levels from C2/3 to L5/S1, whereas facet joint lesions are to be assessed by segmental level (cervical, thoracic, and lumbar). CONCLUSION: An anatomy-based set of definitions and an assessment system for structural lesions in the spine of patients......OBJECTIVE: There is no reliable and sensitive magnetic resonance imaging (MRI) assessment system for structural lesions in patients with spondyloarthritis (SpA). We sought to develop and illustrate a detailed anatomy-based set of MRI definitions and an assessment system for structural lesions...... in the spine of patients with SpA. METHODS: MRI definitions of different structural ("chronic") lesions at various anatomical locations in the spine, and an accompanying assessment system, were agreed by consensus within the Canada-Denmark MRI working group. Subsequently, a reference image set...

  2. Sensor employing internal reference electrode

    DEFF Research Database (Denmark)

    2013-01-01

    The present invention concerns a novel internal reference electrode as well as a novel sensing electrode for an improved internal reference oxygen sensor and the sensor employing same.......The present invention concerns a novel internal reference electrode as well as a novel sensing electrode for an improved internal reference oxygen sensor and the sensor employing same....

  3. Using Proven Reference Monitor Patterns for Security Evaluation

    Directory of Open Access Journals (Sweden)

    Mark R. Heckman

    2016-04-01

    Full Text Available The most effective approach to evaluating the security of complex systems is to deliberately construct the systems using security patterns specifically designed to make them evaluable. Just such an integrated set of security patterns was created decades ago based on the Reference Monitor abstraction. An associated systematic security engineering and evaluation methodology was codified as an engineering standard in the Trusted Computer System Evaluation Criteria (TCSEC. This paper explains how the TCSEC and its Trusted Network Interpretation (TNI constitute a set of security patterns for large, complex and distributed systems and how those patterns have been repeatedly and successfully used to create and evaluate some of the most secure government and commercial systems ever developed.

  4. With Reference to Reference Genes: A Systematic Review of Endogenous Controls in Gene Expression Studies.

    Science.gov (United States)

    Chapman, Joanne R; Waldenström, Jonas

    2015-01-01

    The choice of reference genes that are stably expressed amongst treatment groups is a crucial step in real-time quantitative PCR gene expression studies. Recent guidelines have specified that a minimum of two validated reference genes should be used for normalisation. However, a quantitative review of the literature showed that the average number of reference genes used across all studies was 1.2. Thus, the vast majority of studies continue to use a single gene, with β-actin (ACTB) and/or glyceraldehyde 3-phosphate dehydrogenase (GAPDH) being commonly selected in studies of vertebrate gene expression. Few studies (15%) tested a panel of potential reference genes for stability of expression before using them to normalise data. Amongst studies specifically testing reference gene stability, few found ACTB or GAPDH to be optimal, whereby these genes were significantly less likely to be chosen when larger panels of potential reference genes were screened. Fewer reference genes were tested for stability in non-model organisms, presumably owing to a dearth of available primers in less well characterised species. Furthermore, the experimental conditions under which real-time quantitative PCR analyses were conducted had a large influence on the choice of reference genes, whereby different studies of rat brain tissue showed different reference genes to be the most stable. These results highlight the importance of validating the choice of normalising reference genes before conducting gene expression studies.

  5. A method of camera calibration in the measurement process with reference mark for approaching observation space target

    Science.gov (United States)

    Zhang, Hua; Zeng, Luan

    2017-11-01

    Binocular stereoscopic vision can be used for space-based space targets near observation. In order to solve the problem that the traditional binocular vision system cannot work normally after interference, an online calibration method of binocular stereo measuring camera with self-reference is proposed. The method uses an auxiliary optical imaging device to insert the image of the standard reference object into the edge of the main optical path and image with the target on the same focal plane, which is equivalent to a standard reference in the binocular imaging optical system; When the position of the system and the imaging device parameters are disturbed, the image of the standard reference will change accordingly in the imaging plane, and the position of the standard reference object does not change. The camera's external parameters can be re-calibrated by the visual relationship of the standard reference object. The experimental results show that the maximum mean square error of the same object can be reduced from the original 72.88mm to 1.65mm when the right camera is deflected by 0.4 degrees and the left camera is high and low with 0.2° rotation. This method can realize the online calibration of binocular stereoscopic vision measurement system, which can effectively improve the anti - jamming ability of the system.

  6. Improvements of MCOR: A Monte Carlo depletion code system for fuel assembly reference calculations

    Energy Technology Data Exchange (ETDEWEB)

    Tippayakul, C.; Ivanov, K. [Pennsylvania State Univ., Univ. Park (United States); Misu, S. [AREVA NP GmbH, An AREVA and SIEMENS Company, Erlangen (Germany)

    2006-07-01

    This paper presents the improvements of MCOR, a Monte Carlo depletion code system for fuel assembly reference calculations. The improvements of MCOR were initiated by the cooperation between the Penn State Univ. and AREVA NP to enhance the original Penn State Univ. MCOR version in order to be used as a new Monte Carlo depletion analysis tool. Essentially, a new depletion module using KORIGEN is utilized to replace the existing ORIGEN-S depletion module in MCOR. Furthermore, the online burnup cross section generation by the Monte Carlo calculation is implemented in the improved version instead of using the burnup cross section library pre-generated by a transport code. Other code features have also been added to make the new MCOR version easier to use. This paper, in addition, presents the result comparisons of the original and the improved MCOR versions against CASMO-4 and OCTOPUS. It was observed in the comparisons that there were quite significant improvements of the results in terms of k{sub inf}, fission rate distributions and isotopic contents. (authors)

  7. Reference ranges for blood concentrations of eosinophils and monocytes during the neonatal period defined from over 63 000 records in a multihospital health-care system.

    Science.gov (United States)

    Christensen, R D; Jensen, J; Maheshwari, A; Henry, E

    2010-08-01

    Blood concentrations of eosinophils and monocytes are part of the complete blood count. Reference ranges for these concentrations during the neonatal period, established by very large sample sizes and modern methods, are needed for identifying abnormally low or high values. We constructed reference ranges for eosinophils per microl and monocytes per microl among neonates of 22 to 42 weeks of gestation, on the day of birth, and also during 28 days after birth. Data were obtained from archived electronic records over an eight and one-half-year period in a multihospital health-care system. In keeping with the reference range concept, values were excluded from neonates with a diagnosis of infection or necrotizing enterocolitis (NEC). Eosinophils and monocytes per microl of blood were electronically retrieved from 96 162 records, of which 63 371 that lacked a diagnosis of infection or NEC were included in this reference range report. The mean value for eosinophils per microl on the day of birth increased linearly between 22 and 42 weeks of gestation, as did the 5 and 95% values. The reference range at 40 weeks was 140 to 1300 microl(-1) (mean 550 microl(-1)). Similarly, the mean value for monocytes increased linearly over this interval, with a reference range at 40 weeks of 300 to 3300 microl(-1) (mean 1400 microl(-1)). Over the first 4 weeks after birth, no appreciable change was observed in 5% limit and mean eosinophil count, with a slight increase in the 95% limit in week 4. A slight increase in monocyte count was observed during the first 2 weeks after birth. The results of this analysis describe reference ranges for blood concentrations of eosinophils and monocytes during the neonatal period. Additional study is needed for determining the relevance of values falling outside the reference range.

  8. Time trends and epidemiological patterns of perinatal lamb mortality in Norway.

    Science.gov (United States)

    Holmøy, Ingrid Hunter; Waage, Steinar

    2015-09-30

    Perinatal mortality is a major cause of loss in the sheep industry. Our aim was to explore time trends in crude population stillbirth and neonatal mortality rates in Norway. We used data on 6,435,715 lambs from flocks enrolled in the Norwegian Sheep Recording System (NSRS) from 2000 through 2010 for descriptive analysis of trends. Longitudinal patterns of mortality rates were compared for lambs within different levels of variables suspected to be associated with perinatal loss. There was an approximately linear increase in the annual proportion of stillborn lambs during the study period, from 3.3 % in 2000 to 4.7 % in 2010. In the same time period, average litter size of ewes in NSRS flocks increased from 2.00 to 2.19. However, a steady rise in stillbirth rate was observed within each litter size group, suggesting a gradually increasing impact on stillbirth risk of other, yet unidentified, factors. Average flock size increased during the study period. The highest stillbirth rates were found in the largest and smallest flocks. Early neonatal mortality rates (0-5 days of life) varied from year to year (minimum 2.2 %, maximum 3.2 %) and were invariably higher among triplets and quadruplets than among singletons and twins. Annual fluctuations were parallel within the various litter sizes. A significant overall decreasing trend was present within all litter sizes with the exception of singletons. Weather data for the prime lambing months (April and May) 2000-2010 indicated a relationship between low temperatures and high neonatal mortality rates. At the flock level, there was a significant positive correlation between stillbirths and early neonatal mortality rates (r = 0.13), between stillbirth rates in two consecutive years (r = 0.43) and between early neonatal mortality rates in two consecutive years (r = 0.40). The substantial increase in ovine stillbirth rate in recent years in Norway was to some extent related to a corresponding increase in the

  9. Developing the security culture at the SEISMED Reference Centres.

    Science.gov (United States)

    Fowler, J

    1996-01-01

    The paper gives a brief summary of the SEISMED project and the particular role played by the Reference Centres. Details are given of the hardware and application systems in use in the Royal Hospitals (NHS) Trust (RHT), one of the SEISMED Reference Centres. It proposes, without verification, a definition of a Security Culture based on three criteria. These are suggested to be the "Awareness" the "Acceptance" and the "Actions" of the management and staff to improve Information Systems Security throughout the RHT. The way that "Awareness" was increased is shown by the specific initiatives commenced as a result of a CRAMM Risk Analysis and the management and staff training programmes. The specific initiatives mentioned include, an Information Systems Security Policy, a contingency and disaster recovery plan, improvements in the physical protection of equipment and changes to the method of access control. The "Acceptance" by the staff of these measures is considered and the success or failure of "Developing A Security Culture" examined. The role of SEISMED in this process is assessed.

  10. Reference design description for a geologic repository. Revision 02

    International Nuclear Information System (INIS)

    1999-01-01

    This Reference Design Description explains the current design for a potential geologic repository that may be located at Yucca Mountain in Nevada. It describes the proposed design for a surface facility, subsurface repository, and waste packaging; it also presents the current design of the key engineering systems for the final four phases: operations, monitoring, closure, and postclosure. In addition, this Reference Design Description reviews the expected long-term performance of the potential repository. In accordance with current law, this design does not include an interim storage option. This document has six major sections. Section 1 describes the physical layout of the proposed repository. The second section describes the 4-phase evolution of the development of the proposed repository. Section 3 describes the reception of waste from offsite locations. The fourth section details the various systems that will package the waste and move it below ground as well as safety monitoring and closure. Section 5 describes the systems (both physical and analytical) that ensure continued safety after closure. The final section offers design options that may be adopted to increase the margin of safety

  11. A reference dosimetric system for dose interval of radiotherapy based on alanine/RPE; Um sistema dosimetrico de referencia para o intervalo de doses da radioterapia baseado na alanina/RPE

    Energy Technology Data Exchange (ETDEWEB)

    Rodrigues Junior, Orlando; Galante, Ocimar L.; Campos, Leticia L. [Instituto de Pesquisas Energeticas e Nucleares (IPEN), Sao Paulo, SP (Brazil)]. E-mail: rodrijr@net.ipen.br

    2001-07-01

    This work describes the development of a reference dosimetric system based on alanine/EPR for radiotherapy dose levels. Currently the IPEN is concluding a similar system for the dose range used for irradiation of products, 10-10{sup 5} Gy. The objective of this work is to present the efforts towards to improve the measure accuracy for doses in the range between 1-10 Gy. This system could be used as reference by radiotherapy services, as much in the quality control of the equipment, as for routine accompaniment of more complex handling where the total doses can reach some grays. The system uses alanine as detector and electronic paramagnetic resonance - EPR as measure technique. To reach accuracy better than 5% mathematical studies on the best optimization of the EPR spectrometer parameters and methods for the handling of the EPR sign are discussed. (author)

  12. A Framework Based on Reference Data with Superordinate Accuracy for the Quality Analysis of Terrestrial Laser Scanning-Based Multi-Sensor-Systems.

    Science.gov (United States)

    Stenz, Ulrich; Hartmann, Jens; Paffenholz, Jens-André; Neumann, Ingo

    2017-08-16

    Terrestrial laser scanning (TLS) is an efficient solution to collect large-scale data. The efficiency can be increased by combining TLS with additional sensors in a TLS-based multi-sensor-system (MSS). The uncertainty of scanned points is not homogenous and depends on many different influencing factors. These include the sensor properties, referencing, scan geometry (e.g., distance and angle of incidence), environmental conditions (e.g., atmospheric conditions) and the scanned object (e.g., material, color and reflectance, etc.). The paper presents methods, infrastructure and results for the validation of the suitability of TLS and TLS-based MSS. Main aspects are the backward modelling of the uncertainty on the basis of reference data (e.g., point clouds) with superordinate accuracy and the appropriation of a suitable environment/infrastructure (e.g., the calibration process of the targets for the registration of laser scanner and laser tracker data in a common coordinate system with high accuracy) In this context superordinate accuracy means that the accuracy of the acquired reference data is better by a factor of 10 than the data of the validated TLS and TLS-based MSS. These aspects play an important role in engineering geodesy, where the aimed accuracy lies in a range of a few mm or less.

  13. Space-time reference with an optical link

    International Nuclear Information System (INIS)

    Berceau, P; Hollberg, L; Taylor, M; Kahn, J

    2016-01-01

    We describe a concept for realizing a high performance space-time reference using a stable atomic clock in a precisely defined orbit and synchronizing the orbiting clock to high-accuracy atomic clocks on the ground. The synchronization would be accomplished using a two-way lasercom link between ground and space. The basic approach is to take advantage of the highest-performance cold-atom atomic clocks at national standards laboratories on the ground and to transfer that performance to an orbiting clock that has good stability and that serves as a ‘frequency-flywheel’ over time-scales of a few hours. The two-way lasercom link would also provide precise range information and thus precise orbit determination. With a well-defined orbit and a synchronized clock, the satellite could serve as a high-accuracy space-time reference, providing precise time worldwide, a valuable reference frame for geodesy, and independent high-accuracy measurements of GNSS clocks. Under reasonable assumptions, a practical system would be able to deliver picosecond timing worldwide and millimeter orbit determination, and could serve as an enabling subsystem for other proposed space-gravity missions, which are briefly reviewed. (paper)

  14. On correlation comparison of identical pions in different systems of reference

    International Nuclear Information System (INIS)

    Podgoretskij, M.I.

    1983-01-01

    It is shown that a comparison of correlations of identical pions in reference frames moving with different velocities along the reaction axis enables one to select the frame for which there is a kinematical symmetry in the multiple generation process. The indicated possibility is due to the fact that in the considered symmetrical frame the space-time parameters R and tau are extremal. An experimental selection of the ''symmetrical frame'' may be useful in the choice between competing models of multiple generation

  15. Wave Disturbance Reduction of a Floating Wind Turbine Using a Reference Model-based Predictive Control

    DEFF Research Database (Denmark)

    Christiansen, Søren; Tabatabaeipour, Seyed Mojtaba; Bak, Thomas

    2013-01-01

    pitch such that the state trajectories of the controlled system tracks the reference trajectories. The framework is demonstrated with a reference model of the desired closed-loop system undisturbed by the incident waves. This allows the wave-induced motion of the platform to be damped significantly...... compared to a baseline floating wind turbine controller at the cost of more pitch action....

  16. A Federated Reference Structure for Open Informational Ecosystems

    Science.gov (United States)

    Heinen, Richard; Kerres, Michael; Scharnberg, Gianna; Blees, Ingo; Rittberger, Marc

    2016-01-01

    The paper describes the concept of a federated ecosystem for Open Educational Resources (OER) in the German education system. Here, a variety of OER repositories (ROER) (Muuß-Merholz & Schaumburg, 2014) and reference platforms have been established in the recent past. In order to develop this ecosystem, not only are metadata standards…

  17. Swiss hydropower in competition - an analysis with reference to the future European power supply system

    International Nuclear Information System (INIS)

    Balmer, M.; Spreng, D.; Moest, D.

    2006-01-01

    This article takes a look at a number of questions in relation to the future use of Swiss hydropower that are neither clear nor unchallenged. Questions concerning the replacement or refurbishment of hydropower schemes that will have to be renewed in the next few years are asked. Also, developments in the European power market are looked at. The future influence of wind power, trading with CO 2 certificates, increases in the price of gas etc. are examined. An analysis of the competitiveness of Swiss hydropower with reference to the European power supply system that was made by the Centre for Energy Policy and Economics CEPE at the Swiss Federal Institute of Technology ETH is described. The 'Perseus'-model developed by CEPE and the Industrial Technology Institute at the University of Karlsruhe in Germany is used to analyse possible developments over the period up to 2030. The results are presented in graphical form and commented on

  18. CMS Statistics Reference Booklet

    Data.gov (United States)

    U.S. Department of Health & Human Services — The annual CMS Statistics reference booklet provides a quick reference for summary information about health expenditures and the Medicare and Medicaid health...

  19. The Nuclear Science References (NSR) database and Web Retrieval System

    International Nuclear Information System (INIS)

    Pritychenko, B.; Betak, E.; Kellett, M.A.; Singh, B.; Totans, J.

    2011-01-01

    The Nuclear Science References (NSR) database together with its associated Web interface is the world's only comprehensive source of easily accessible low- and intermediate-energy nuclear physics bibliographic information for more than 200,000 articles since the beginning of nuclear science. The weekly updated NSR database provides essential support for nuclear data evaluation, compilation and research activities. The principles of the database and Web application development and maintenance are described. Examples of nuclear structure, reaction and decay applications are specifically included. The complete NSR database is freely available at the websites of the National Nuclear Data Center (http://www.nndc.bnl.gov/nsr) and the International Atomic Energy Agency (http://www-nds.iaea.org/nsr).

  20. Certified reference materials and reference methods for nuclear safeguards and security.

    Science.gov (United States)

    Jakopič, R; Sturm, M; Kraiem, M; Richter, S; Aregbe, Y

    2013-11-01

    Confidence in comparability and reliability of measurement results in nuclear material and environmental sample analysis are established via certified reference materials (CRMs), reference measurements, and inter-laboratory comparisons (ILCs). Increased needs for quality control tools in proliferation resistance, environmental sample analysis, development of measurement capabilities over the years and progress in modern analytical techniques are the main reasons for the development of new reference materials and reference methods for nuclear safeguards and security. The Institute for Reference Materials and Measurements (IRMM) prepares and certifices large quantities of the so-called "large-sized dried" (LSD) spikes for accurate measurement of the uranium and plutonium content in dissolved nuclear fuel solutions by isotope dilution mass spectrometry (IDMS) and also develops particle reference materials applied for the detection of nuclear signatures in environmental samples. IRMM is currently replacing some of its exhausted stocks of CRMs with new ones whose specifications are up-to-date and tailored for the demands of modern analytical techniques. Some of the existing materials will be re-measured to improve the uncertainties associated with their certified values, and to enable laboratories to reduce their combined measurement uncertainty. Safeguards involve the quantitative verification by independent measurements so that no nuclear material is diverted from its intended peaceful use. Safeguards authorities pay particular attention to plutonium and the uranium isotope (235)U, indicating the so-called 'enrichment', in nuclear material and in environmental samples. In addition to the verification of the major ratios, n((235)U)/n((238)U) and n((240)Pu)/n((239)Pu), the minor ratios of the less abundant uranium and plutonium isotopes contain valuable information about the origin and the 'history' of material used for commercial or possibly clandestine purposes, and

  1. Robust Floor Determination Algorithm for Indoor Wireless Localization Systems under Reference Node Failure

    Directory of Open Access Journals (Sweden)

    Kriangkrai Maneerat

    2016-01-01

    Full Text Available One of the challenging problems for indoor wireless multifloor positioning systems is the presence of reference node (RN failures, which cause the values of received signal strength (RSS to be missed during the online positioning phase of the location fingerprinting technique. This leads to performance degradation in terms of floor accuracy, which in turn affects other localization procedures. This paper presents a robust floor determination algorithm called Robust Mean of Sum-RSS (RMoS, which can accurately determine the floor on which mobile objects are located and can work under either the fault-free scenario or the RN-failure scenarios. The proposed fault tolerance floor algorithm is based on the mean of the summation of the strongest RSSs obtained from the IEEE 802.15.4 Wireless Sensor Networks (WSNs during the online phase. The performance of the proposed algorithm is compared with those of different floor determination algorithms in literature. The experimental results show that the proposed robust floor determination algorithm outperformed the other floor algorithms and can achieve the highest percentage of floor determination accuracy in all scenarios tested. Specifically, the proposed algorithm can achieve greater than 95% correct floor determination under the scenario in which 40% of RNs failed.

  2. Memory systems in the rat: effects of reward probability, context, and congruency between working and reference memory.

    Science.gov (United States)

    Roberts, William A; Guitar, Nicole A; Marsh, Heidi L; MacDonald, Hayden

    2016-05-01

    The interaction of working and reference memory was studied in rats on an eight-arm radial maze. In two experiments, rats were trained to perform working memory and reference memory tasks. On working memory trials, they were allowed to enter four randomly chosen arms for reward in a study phase and then had to choose the unentered arms for reward in a test phase. On reference memory trials, they had to learn to visit the same four arms on the maze on every trial for reward. Retention was tested on working memory trials in which the interval between the study and test phase was 15 s, 15 min, or 30 min. At each retention interval, tests were performed in which the correct WM arms were either congruent or incongruent with the correct RM arms. Both experiments showed that congruency interacted with retention interval, yielding more forgetting at 30 min on incongruent trials than on congruent trials. The effect of reference memory strength on the congruency effect was examined in Experiment 1, and the effect of associating different contexts with working and reference memory on the congruency effect was studied in Experiment 2.

  3. Refer-To-Pharmacy: Pharmacy for the Next Generation Now! A Short Communication for Pharmacy

    OpenAIRE

    Gray, Alistair

    2015-01-01

    Refer-to-Pharmacy is the first fully integrated hospital to community pharmacy referral system. This article explains the importance of these referrals for patients and health economies to improve medicines optimisation, and how Refer-to-Pharmacy works in both hospital and community pharmacies.

  4. Block correlated second order perturbation theory with a generalized valence bond reference function

    International Nuclear Information System (INIS)

    Xu, Enhua; Li, Shuhua

    2013-01-01

    The block correlated second-order perturbation theory with a generalized valence bond (GVB) reference (GVB-BCPT2) is proposed. In this approach, each geminal in the GVB reference is considered as a “multi-orbital” block (a subset of spin orbitals), and each occupied or virtual spin orbital is also taken as a single block. The zeroth-order Hamiltonian is set to be the summation of the individual Hamiltonians of all blocks (with explicit two-electron operators within each geminal) so that the GVB reference function and all excited configuration functions are its eigenfunctions. The GVB-BCPT2 energy can be directly obtained without iteration, just like the second order Møller–Plesset perturbation method (MP2), both of which are size consistent. We have applied this GVB-BCPT2 method to investigate the equilibrium distances and spectroscopic constants of 7 diatomic molecules, conformational energy differences of 8 small molecules, and bond-breaking potential energy profiles in 3 systems. GVB-BCPT2 is demonstrated to have noticeably better performance than MP2 for systems with significant multi-reference character, and provide reasonably accurate results for some systems with large active spaces, which are beyond the capability of all CASSCF-based methods

  5. Block correlated second order perturbation theory with a generalized valence bond reference function.

    Science.gov (United States)

    Xu, Enhua; Li, Shuhua

    2013-11-07

    The block correlated second-order perturbation theory with a generalized valence bond (GVB) reference (GVB-BCPT2) is proposed. In this approach, each geminal in the GVB reference is considered as a "multi-orbital" block (a subset of spin orbitals), and each occupied or virtual spin orbital is also taken as a single block. The zeroth-order Hamiltonian is set to be the summation of the individual Hamiltonians of all blocks (with explicit two-electron operators within each geminal) so that the GVB reference function and all excited configuration functions are its eigenfunctions. The GVB-BCPT2 energy can be directly obtained without iteration, just like the second order Mo̸ller-Plesset perturbation method (MP2), both of which are size consistent. We have applied this GVB-BCPT2 method to investigate the equilibrium distances and spectroscopic constants of 7 diatomic molecules, conformational energy differences of 8 small molecules, and bond-breaking potential energy profiles in 3 systems. GVB-BCPT2 is demonstrated to have noticeably better performance than MP2 for systems with significant multi-reference character, and provide reasonably accurate results for some systems with large active spaces, which are beyond the capability of all CASSCF-based methods.

  6. The generation and management of references with the Online Mechanism for References - MORE

    Directory of Open Access Journals (Sweden)

    Proxério Manoel Felisberto

    2015-04-01

    Full Text Available The scientific production and the development of academic papers have their own formalities. In this paper, is sought seek from these formalities for the ones that refers to the way of granting merits to the authors of the works used in the theoretical basis, through quotations and references. The goal is to help users of libraries to generate and manage references using a web tool developed for this purpose. There are many applications, in desktop and web platforms, that could be used to do this task. However, some of them require the payment of an expensive license to be fully functional. Others offers free versions, but they are very limited and often do not generate references specified by ABNT. There are others that do not store the generate references for later use. In order to fill this gap, the Online Mechanism for References (MORE was developed and made available to the general public in the web. Even so, the fast technological advances combined with a high number of users demanded an update to the application, done recently. It is important to state that all the work was developed exclusively with proven and free to use technologies. Initially, sought up identified the main tools available to generate and manage references and which free technologies could be used to build interactive web applications. This paper briefly describes the reengineering process that MORE was submitted, its new structure, new requirements met and its expanded portfolio of features. Finally, the results achieved after the reengineering are compared to indicators of its previous version.

  7. Generic Argillite/Shale Disposal Reference Case

    Energy Technology Data Exchange (ETDEWEB)

    Zheng, Liange; Colon, Carlos Jové; Bianchi, Marco; Birkholzer, Jens

    2014-08-08

    Radioactive waste disposal in a deep subsurface repository hosted in clay/shale/argillite is a subject of widespread interest given the desirable isolation properties, geochemically reduced conditions, and widespread geologic occurrence of this rock type (Hansen 2010; Bianchi et al. 2013). Bianchi et al. (2013) provides a description of diffusion in a clay-hosted repository based on single-phase flow and full saturation using parametric data from documented studies in Europe (e.g., ANDRA 2005). The predominance of diffusive transport and sorption phenomena in this clay media are key attributes to impede radionuclide mobility making clay rock formations target sites for disposal of high-level radioactive waste. The reports by Hansen et al. (2010) and those from numerous studies in clay-hosted underground research laboratories (URLs) in Belgium, France and Switzerland outline the extensive scientific knowledge obtained to assess long-term clay/shale/argillite repository isolation performance of nuclear waste. In the past several years under the UFDC, various kinds of models have been developed for argillite repository to demonstrate the model capability, understand the spatial and temporal alteration of the repository, and evaluate different scenarios. These models include the coupled Thermal-Hydrological-Mechanical (THM) and Thermal-Hydrological-Mechanical-Chemical (THMC) models (e.g. Liu et al. 2013; Rutqvist et al. 2014a, Zheng et al. 2014a) that focus on THMC processes in the Engineered Barrier System (EBS) bentonite and argillite host hock, the large scale hydrogeologic model (Bianchi et al. 2014) that investigates the hydraulic connection between an emplacement drift and surrounding hydrogeological units, and Disposal Systems Evaluation Framework (DSEF) models (Greenberg et al. 2013) that evaluate thermal evolution in the host rock approximated as a thermal conduction process to facilitate the analysis of design options. However, the assumptions and the

  8. Committee on Diabetes Mellitus Indices of the Japan Society of Clinical Chemistry-recommended reference measurement procedure and reference materials for glycated albumin determination.

    Science.gov (United States)

    Takei, Izumi; Hoshino, Tadao; Tominaga, Makoto; Ishibashi, Midori; Kuwa, Katsuhiko; Umemoto, Masao; Tani, Wataru; Okahashi, Mikiko; Yasukawa, Keiko; Kohzuma, Takuji; Sato, Asako

    2016-01-01

    Glycated albumin is an intermediate glycaemic control marker for which there are several measurement procedures with entirely different reference intervals. We have developed a reference measurement procedure for the purpose of standardizing glycated albumin measurements. The isotope dilution liquid chromatography/tandem mass spectrometry method was developed as a reference measurement procedure for glycated albumin. The stable isotopes of lysine and fructosyl-lysine, which serve as an internal standard, were added to albumin isolated from serum, followed by hydrogenation. After hydrolysis of albumin with hot hydrochloric acid, the liberated lysine and fructosyl-lysine were measured by liquid chromatography/tandem mass spectrometry, and their concentrations were determined from each isotope ratio. The reference materials (JCCRM611) for determining of glycated albumin were prepared from pooled patient blood samples. The isotope dilution-tandem mass spectrometry calibration curve of fructosyl-lysine and lysine showed good linearity (r = 0.999). The inter-assay and intra-assay coefficient of variation values of glycated albumin measurement were 1.2 and 1.4%, respectively. The glycated albumin values of serum in patients with diabetes assessed through the use of this method showed a good relationship with routine measurement procedures (r = 0.997). The relationship of glycated albumin values of the reference material (JCCRM611) between these two methods was the same as the relationship with the patient serum samples. The Committee on Diabetes Mellitus Indices of the Japan Society of Clinical Chemistry recommends the isotope dilution liquid chromatography/tandem mass spectrometry method as a reference measurement procedure, and JCCRM611 as a certified reference material for glycated albumin measurement. In addition, we recommend the traceability system for glycated albumin measurement. © The Author(s) 2015.

  9. Comparison of the reference mark azimuth determination methods

    Directory of Open Access Journals (Sweden)

    Danijel Šugar

    2013-03-01

    Full Text Available The knowledge of the azimuth of the reference mark is of crucial importance in the determination of the declination which is defined as the ellipsoidal (geodetic azimuth of the geomagnetic meridian. The accuracy of the azimuth determination has direct impact on the accuracy of the declination. The orientation of the Declination-Inclination Magnetometer is usually carried out by sighting the reference mark in two telescope faces in order to improve the reliability of the observations and eliminate some instrumental errors. In this paper, different coordinate as well as azimuth determination methods using GNSS (Global Navigation Satellite System observation techniques within VPPS (High-Precision Positioning Service and GPPS (Geodetic-Precision Positioning Service services of the CROPOS (CROatian POsitioning System system were explained. The azimuth determination by the observation of the Polaris was exposed and it was subsequently compared with the observation of the Sun using hour-angle and zenith-distance method. The procedure of the calculation of the geodetic azimuth from the astronomic azimuth was explained. The azimuth results obtained by different methods were compared and the recommendations on the minimal distance between repeat station and azimuth mark were given. The results shown in this paper were based on the observations taken on the POKU_SV repeat station.

  10. Verification of status of reference of Brainscan planning system through Grafchromic EBT3

    International Nuclear Information System (INIS)

    Vazquez Vazquez, R.; Ambroa Rey, E. M.; Gimenez Insua, M.; Luna Vega, V.; Mosquera Sueiro, J.; Lobato Busto, R.; Sanchez Garcia, M.; Otero Martinez, C.; Pombar Camean, M.

    2013-01-01

    To compare the State of current of the Brainscan planner with the initial reference State has been successful. This new detector shows behavior similar to its predecessor (Gafchromic EBT2), but without the disadvantages arising from the construction of the same. (Author)

  11. Computation and brain processes, with special reference to neuroendocrine systems.

    Science.gov (United States)

    Toni, Roberto; Spaletta, Giulia; Casa, Claudia Della; Ravera, Simone; Sandri, Giorgio

    2007-01-01

    The development of neural networks and brain automata has made neuroscientists aware that the performance limits of these brain-like devices lies, at least in part, in their computational power. The computational basis of a. standard cybernetic design, in fact, refers to that of a discrete and finite state machine or Turing Machine (TM). In contrast, it has been suggested that a number of human cerebral activites, from feedback controls up to mental processes, rely on a mixing of both finitary, digital-like and infinitary, continuous-like procedures. Therefore, the central nervous system (CNS) of man would exploit a form of computation going beyond that of a TM. This "non conventional" computation has been called hybrid computation. Some basic structures for hybrid brain computation are believed to be the brain computational maps, in which both Turing-like (digital) computation and continuous (analog) forms of calculus might occur. The cerebral cortex and brain stem appears primary candidate for this processing. However, also neuroendocrine structures like the hypothalamus are believed to exhibit hybrid computional processes, and might give rise to computational maps. Current theories on neural activity, including wiring and volume transmission, neuronal group selection and dynamic evolving models of brain automata, bring fuel to the existence of natural hybrid computation, stressing a cooperation between discrete and continuous forms of communication in the CNS. In addition, the recent advent of neuromorphic chips, like those to restore activity in damaged retina and visual cortex, suggests that assumption of a discrete-continuum polarity in designing biocompatible neural circuitries is crucial for their ensuing performance. In these bionic structures, in fact, a correspondence exists between the original anatomical architecture and synthetic wiring of the chip, resulting in a correspondence between natural and cybernetic neural activity. Thus, chip "form

  12. Preparation and characterization of the fish reference material

    International Nuclear Information System (INIS)

    Ulrich, Joao Cristiano

    2011-01-01

    The certified reference materials (CRMs) play an important role in obtaining measurement results traceable to the International System of Units, through an unbroken chain of comparisons. Thus, the demand for new certified reference materials (CRMs) increases every day in all areas of knowledge. The availability of reference materials, mainly in Brazil is still incipient, given that the demand far exceeds the available variety of these materials. The amount of certified reference materials available in the country is insufficient to meet the need of the scientific community and demands for development of new methodologies. Among the many areas in need of reference materials, we highlight the importance for the food trade balance for these products within the country. The certification of food products, intended both for export and for domestic consumption, requires analysis methods that provide precise and accurate results to ensure product quality. This paper describes the preparation and certification of a reference material in the fish matrix in mercury and methylmercury. The study brings together since the stage of material selection, preparation, development of homogeneity and stability studies and characterization. The certification was performed by means of measurements using two analytical techniques, flow injection analysis - cold vapor atomic absorption spectrometry (FIA-CV-AAS) and isotope dilution applied to mass spectrometry (IDMS), which is a primary method. In this work the standards of the ISO 30 (ABNT 30-34) and ISO Guide 35 was used as the basis for the preparation and characterization of the material. For the calculation of uncertainties was used the GUM and Eurachem guide. As a result, was produced and certified a lot of material in relation to the concentration of mercury (Hg = 0.271 ± 0.057 mg g -1 ) and methylmercury (MeHg = 0.245 ± 0.038 mg g -1 ), and informational values of lead and arsenic. (author)

  13. An Internet of Things Generic Reference Architecture

    DEFF Research Database (Denmark)

    Bhalerao, Dipashree M.; Riaz, Tahir; Madsen, Ole Brun

    2013-01-01

    Internet of things Network is a future application of Internet. This network has three major basic blocks as business process or Application, core network or internetwork and peripheral network as Things or objects. The assembly has the basic intention of connecting all physical and virtual things......, and keeping track of all these things for monitoring and controlling some information. IoT architecture is studied from software architecture, overall system architecture and network architecture point of view. Paper puts forward the requirements of software architecture along with, its component...... and deployment diagram, process and interface diagram at abstract level. Paper proposes the abstract generic IoT reference and concrete abstract generic IoT reference architectures. Network architecture is also put up as a state of the art. Paper shortly gives overviews of protocols used for IoT. Some...

  14. [Errors in Peruvian medical journals references].

    Science.gov (United States)

    Huamaní, Charles; Pacheco-Romero, José

    2009-01-01

    References are fundamental in our studies; an adequate selection is asimportant as an adequate description. To determine the number of errors in a sample of references found in Peruvian medical journals. We reviewed 515 scientific papers references selected by systematic randomized sampling and corroborated reference information with the original document or its citation in Pubmed, LILACS or SciELO-Peru. We found errors in 47,6% (245) of the references, identifying 372 types of errors; the most frequent were errors in presentation style (120), authorship (100) and title (100), mainly due to spelling mistakes (91). References error percentage was high, varied and multiple. We suggest systematic revision of references in the editorial process as well as to extend the discussion on this theme. references, periodicals, research, bibliometrics.

  15. Indoor air: Reference bibliography

    International Nuclear Information System (INIS)

    Campbell, D.; Staves, D.; McDonald, S.

    1989-07-01

    The U. S. Environmental Protection Agency initially established the indoor air Reference Bibliography in 1987 as an appendix to the Indoor Air Quality Implementation Plan. The document was submitted to Congress as required under Title IV--Radon Gas and Indoor Air Quality Research of the Superfund Amendments and Reauthorization Act of 1986. The Reference Bibliography is an extensive bibliography of reference materials on indoor air pollution. The Bibliography contains over 4500 citations and continues to increase as new articles appear

  16. Results of reference pricing and reimbursement discount rate schemes of Turkey

    Directory of Open Access Journals (Sweden)

    Guvenc Kockaya

    2013-06-01

    Full Text Available OBJECTIVES: General Directorate of Pharmaceuticals and Pharmacy (IEGM is responsible for setting all prices for human medicinal products. The reference pricing system is used for setting these prices. Reference countries are reviewed annually and may be subject to certain alterations. There were 5 reference countries in 2009: Spain, Italy, Germany, France and Greece. The aim of this study is to show the distribution of reference countries which were used for reference pricing.METHODS: The price list of pharmaceuticals which was published by IEGM on 15.04.2011 was used for analysis. Distribution of reference countries and prices were evaluated.RESULTS: Prices of 6,251 generic and 3,703 original products were set according to the price list. 5,283 of generics and 3,306 of originals were in the positive list for reimbursement. Reference pricing was used for 2,352 generics and 2,281 originals. Prices of the remaining were set outside of reference pricing. 32 different countries were used for reference pricing. Italy was the most popular country for reference pricing. Even if it was not a reference country, Germany was used in some of the pharmaceuticals. The average reimbursement discount rate and price were 24.43% and 249 TL, respectively. There were no colerations between price and reimbursement discount rate, or reference country and reimbursement rate.CONCLUSION: It has been shown that Italy has the highest impact on the pricing of all pharmaceuticals in Turkey. Even if it was not a reference country, Germany showed to affect pharmaceuticals more than other countries which were also not used for reference pricing. Even if reimbursement discount rates are stated by the Social Security Institution (SGK, there are different discount rates for pharmaceuticals. The analysis stated that there were correlation between price, country and discount rates. This analysis is first for the literature. Further analysis is necessary in the light of price

  17. The Role of Theory Adaptation in the Making of a Reference Discipline

    DEFF Research Database (Denmark)

    Kjærgaard, Annemette; Vendelø, Morten Thanning

    2015-01-01

    Information Systems (IS) scholars repeatedly debate the nature of the IS discipline. A series of articles have debated whether the IS field has become a reference discipline. While many scholars have argued this question from a perceptual point of view, we address it by examining the role of theo...... adaptation, have a higher probability of being referenced by other disciplines. Finally, we discuss the implications of the manner in which IS scholars borrow theory regarding the IS discipline's prospects of becoming a reference discipline.......Information Systems (IS) scholars repeatedly debate the nature of the IS discipline. A series of articles have debated whether the IS field has become a reference discipline. While many scholars have argued this question from a perceptual point of view, we address it by examining the role of theory...... adaptation in the making of a reference discipline. Based on a review of how the sensemaking theory from organization studies is adapted and used in IS research, we show that papers that adapt and use sensemaking theory as a central construct in the theoretical framework – in other words – engaging in theory...

  18. Impact of quasar proper motions on the alignment between the International Celestial Reference Frame and the Gaia reference frame

    Science.gov (United States)

    Liu, J.-C.; Malkin, Z.; Zhu, Z.

    2018-03-01

    The International Celestial Reference Frame (ICRF) is currently realized by the very long baseline interferometry (VLBI) observations of extragalactic sources with the zero proper motion assumption, while Gaia will observe proper motions of these distant and faint objects to an accuracy of tens of microarcseconds per year. This paper investigates the difference between VLBI and Gaia quasar proper motions and it aims to understand the impact of quasar proper motions on the alignment of the ICRF and Gaia reference frame. We use the latest time series data of source coordinates from the International VLBI Service analysis centres operated at Goddard Space Flight Center (GSF2017) and Paris observatory (OPA2017), as well as the Gaia auxiliary quasar solution containing 2191 high-probability optical counterparts of the ICRF2 sources. The linear proper motions in right ascension and declination of VLBI sources are derived by least-squares fits while the proper motions for Gaia sources are simulated taking into account the acceleration of the Solar system barycentre and realistic uncertainties depending on the source brightness. The individual and global features of source proper motions in GSF2017 and OPA2017 VLBI data are found to be inconsistent, which may result from differences in VLBI observations, data reduction and analysis. A comparison of the VLBI and Gaia proper motions shows that the accuracies of the components of rotation and glide between the two systems are 2-4 μas yr- 1 based on about 600 common sources. For the future alignment of the ICRF and Gaia reference frames at different wavelengths, the proper motions of quasars must necessarily be considered.

  19. Long term file migration. Part I: file reference patterns

    International Nuclear Information System (INIS)

    Smith, A.J.

    1978-08-01

    In most large computer installations, files are moved between on-line disk and mass storage (tape, integrated mass storage device) either automatically by the system or specifically at the direction of the user. This is the first of two papers which study the selection of algorithms for the automatic migration of files between mass storage and disk. The use of the text editor data sets at the Stanford Linear Accelerator Center (SLAC) computer installation is examined through the analysis of thirteen months of file reference data. Most files are used very few times. Of those that are used sufficiently frequently that their reference patterns may be examined, about a third show declining rates of reference during their lifetime; of the remainder, very few (about 5%) show correlated interreference intervals, and interreference intervals (in days) appear to be more skewed than would occur with the Bernoulli process. Thus, about two-thirds of all sufficiently active files appear to be referenced as a renewal process with a skewed interreference distribution. A large number of other file reference statistics (file lifetimes, interference distributions, moments, means, number of uses/file, file sizes, file rates of reference, etc.) are computed and presented. The results are applied in the following paper to the development and comparative evaluation of file migration algorithms. 17 figures, 13 tables

  20. Reference Values for Cardiac and Aortic Magnetic Resonance Imaging in Healthy, Young Caucasian Adults

    NARCIS (Netherlands)

    Eikendal, Anouk L M; Bots, Michiel L; Haaring, Cees; Saam, Tobias; van der Geest, Rob J; Westenberg, Jos J M; den Ruijter, Hester M; Hoefer, Imo E; Leiner, Tim

    2016-01-01

    BACKGROUND: Reference values for morphological and functional parameters of the cardiovascular system in early life are relevant since they may help to identify young adults who fall outside the physiological range of arterial and cardiac ageing. This study provides age and sex specific reference

  1. Subjective stress reactivity in psoriasis - a cross sectional study of associated psychological traits.

    Science.gov (United States)

    Remröd, Charlotta; Sjöström, Karin; Svensson, Åke

    2015-05-02

    Stress or psychological distress is often described as a causative or maintaining factor in psoriasis. Psychological traits may influence the appraisal, interpretation and coping ability regarding stressful situations. Detailed investigations of psychological traits in relation to stress reactivity in psoriasis are rare. The aim of this study was to examine whether patients with psoriasis who report an association between psychological distress and exacerbation, "stress reactors" (SRs), differ psychologically from those with no stress reactivity "non-stress reactors" (NSRs). This cross-sectional study was conducted among 101 consecutively recruited outpatients with plaque psoriasis. A psychosocial interview was performed including questions concerning stress reactivity in relation to onset and exacerbation. Three validated self-rating scales were used: Spielberger State-Trait Anxiety Inventory (STAI, Form-Y), Beck Depression Inventory (BDI-II) and Swedish Universities Scales of Personality (SSP). Independent samples t-tests, Chi-square tests and one-way ANOVA analyses were used for group comparisons when appropriate. A logistic regression model was designed with SR as the dependent variable. Sixty-four patients (63%) reported a subjective association between disease exacerbation and stress (SRs). Patients defined as SRs reported significantly higher mean scores regarding state and trait anxiety, depression, and also five SSP scale personality traits, i.e. somatic trait anxiety, psychic trait anxiety, stress susceptibility, lack of assertiveness and mistrust, compared with NSRs. In multivariate analysis, SSP-stress susceptibility was the strongest explanatory variable for SR, i.e. OR (95% CI)=1.13 (1.02 - 1.24), p=0.018. According to our results, patients who perceive stress as a causal factor in their psoriasis might have a more vulnerable psychological constitution. This finding suggests important opportunities for clinicians to identify patients who may benefit

  2. Kerlinger's Criterial Referents Theory Revisited.

    Science.gov (United States)

    Zak, Itai; Birenbaum, Menucha

    1980-01-01

    Kerlinger's criterial referents theory of attitudes was tested cross-culturally by administering an education attitude referents summated-rating scale to 713 individuals in Israel. The response pattern to criterial and noncriterial referents was examined. Results indicated empirical cross-cultural validity of theory, but questioned measuring…

  3. [On establishing comparative reference system for syndrome classification study from the thinking characteristics of syndrome differentiation dependent therapy].

    Science.gov (United States)

    Liu, Ping; Hu, Yi-yang; Ni, Li-qiang

    2006-05-01

    To create a comparative referential system for syndrome classification study by viewing from the thinking characteristics of TCM on syndrome differentiation dependent therapy (SDDT), through analyzing the thinking process of SDDT, and the basic features of disease, syndrome and prescription, combining the basic principles of modern evidence-based medicine and feasibility of establishing integrative disease-syndrome animal model. The practice of creating a comparative referential system based on clinical efficacy of prescription was discussed around syndrome pathogenesis and its relationship with disease and prescription, which was one of the important scientific problems in TCM syndrome study. The authors hold that, it may be one of the available approaches for the present study on integration of disease with syndrome by way of insisting on the thinking pathway of stressing the characteristics of TCM and intermerging with modern scientific design; on taking the efficacy of prescription as the comparative reference system to accumulate and improve unceasingly according to the TCM method of syndrome diagnosis inferred from effect of prescription with reverse thought (i.e., to differentiate syndrome from the effect of prescription), and thus build up the syndrome diagnostic standard on the solid clinical and scientific base.

  4. Model reference adaptive control and adaptive stability augmentation

    DEFF Research Database (Denmark)

    Henningsen, Arne; Ravn, Ole

    1993-01-01

    A comparison of the standard concepts in MRAC design suggests that a combination of the implicit and the explicit design techniques may lead to an improvement of the overall system performance in the presence of unmodelled dynamics. Using the ideas of adaptive stability augmentation a combined...... stability augmented model reference design is proposed. By utilizing the closed-loop control error, a simple auxiliary controller is tuned, using a normalized MIT rule for the parameter adjustment. The MIT adjustment is protected against the effects of unmodelled dynamics by lowpass filtering...... of the gradient. The proposed method is verified through simulation results indicating that the method may lead to an improvement of the model reference controller in the presence of unmodelled dynamics...

  5. ASTM reference radiologic digital image standards

    International Nuclear Information System (INIS)

    Wysnewski, R.; Wysnewski, D.

    1996-01-01

    ASTM Reference Radiographs have been essential in defining industry's material defect grade levels for many years. ASTM Reference Radiographs are used extensively as even the American Society for Metals Nondestructive Inspection and Quality Control Metals Handbook, Volume 11, eighth edition refers to ASTM Standard Reference Radiographs. The recently published E 1648 Standard Reference Radiographs for Examination of Aluminum Fusion Welds is a prime example of the on-going need for these references. To date, 14 Standard Reference Radiographs have been published to characterize material defects. Standard Reference Radiographs do not adequately address film-less radiologic methods. There are differences in mediums to content with. On a computer CRT defect indications appear differently when compared to indications viewed in a radiograph on a view box. Industry that uses non-film radiologic methods of inspection can be burdened with additional time and money developing internal standard reference radiologic images. These references may be deemed necessary for grading levels of product defects. Because there are no ASTM Standard Reference Radiologic data files for addressing this need in the industry, the authors of this paper suggested implementing a method for their creation under ASTM supervision. ASTM can assure continuity to those users making the transition from analog radiographic images to digital image data by swiftly addressing the requirements for reference digital image standards. The current status and possible future activities regarding a method to create digital data files is presented in this paper summary

  6. A future large-aperture UVOIR space observatory: reference designs

    Science.gov (United States)

    Rioux, Norman; Thronson, Harley; Feinberg, Lee; Stahl, H. Philip; Redding, Dave; Jones, Andrew; Sturm, James; Collins, Christine; Liu, Alice

    2015-09-01

    Our joint NASA GSFC/JPL/MSFC/STScI study team has used community-provided science goals to derive mission needs, requirements, and candidate mission architectures for a future large-aperture, non-cryogenic UVOIR space observatory. We describe the feasibility assessment of system thermal and dynamic stability for supporting coronagraphy. The observatory is in a Sun-Earth L2 orbit providing a stable thermal environment and excellent field of regard. Reference designs include a 36-segment 9.2 m aperture telescope that stows within a five meter diameter launch vehicle fairing. Performance needs developed under the study are traceable to a variety of reference designs including options for a monolithic primary mirror.

  7. Flexible Software Design for Korean WA-DGNSS Reference Station

    Directory of Open Access Journals (Sweden)

    Wan Sik Choi

    2013-03-01

    Full Text Available In this paper, we describe the software design results of WA-DGNSS reference station that will be constructed in Korea in the near future. Software design of the WRS (Wide area Reference Station is carried out by applying object oriented software methodology in order to provide flexibilities: easy of model change (namely ionospheric delay model etc and system addition (Galileo, GLONASS in addition to GPS etc. Software design results include the use case diagrams for the functions to be executed, the architecture diagram showing components and their relationships, the activity diagrams of behaviors and models among them, and class diagrams describing the attribute and operation.

  8. Advanced distributed simulation technology: Digital Voice Gateway Reference Guide

    Science.gov (United States)

    Vanhook, Dan; Stadler, Ed

    1994-01-01

    The Digital Voice Gateway (referred to as the 'DVG' in this document) transmits and receives four full duplex encoded speech channels over the Ethernet. The information in this document applies only to DVG's running firmware of the version listed on the title page. This document, previously named Digital Voice Gateway Reference Guide, BBN Systems and Technologies Corporation, Cambridge, MA 02138, was revised for revision 2.00. This new revision changes the network protocol used by the DVG, to comply with the SINCGARS radio simulation (For SIMNET 6.6.1). Because of the extensive changes to revision 2.00 a separate document was created rather than supplying change pages.

  9. Reference dosimetry for helical tomotherapy: Practical implementation and a multicenter validation

    International Nuclear Information System (INIS)

    De Ost, B.; Schaeken, B.; Vynckier, S.; Sterpin, E.; Van den Weyngaert, D.

    2011-01-01

    Purpose: The aim of this study was to implement a protocol for reference dosimetry in tomotherapy and to validate the beam output measurements with an independent dosimetry system. Methods: Beam output was measured at the reference depth of 10 cm in water for the following three cases: (1) a 5 x 10 cm 2 static machine specific reference field (MSR), (2) a rotational 5 x 10 cm 2 field without modulation and no tabletop in the beam, (3) a plan class specific reference (PCSR) field defined as a rotational homogeneous dose delivery to a cylindrical shaped target volume: plan with modulation and table-top movement. The formalism for reference dosimetry of small and nonstandard fields [Med.Phys.35: 5179-5186, 2008] and QA recommendations [Med.Phys.37: 4817-4853, 2010] were adopted in the dose measurement protocol. All ionization chamber measurements were verified independently using alanine/EPR dosimetry. As a pilot study, the beam output was measured on tomotherapy Hi-art systems at three other centers and directly compared to the centers specifications and to alanine dosimetry. Results: For the four centers, the mean static output at a depth of 10 cm in water and SAD = 85 cm, measured with an A1SL chamber following the TG-148 report was 6.238 Gy/min ± 0.058 (1 SD); the rotational output was 6.255 Gy/min ± 0.069 (1 SD). The dose stated by the center was found in good agreement with the measurements of the visiting team: D center /D visit = 1.000 ± 0.003 (1 SD). The A1SL chamber measurements were all in good agreement with Alanine/EPR dosimetry. Going from the static reference field to the rotational/non modulated field the dose rate remains constant within 0.2% except for one center where a deviation of 1.3% was detected. Conclusions: Following the TG-148 report, beam output measurements in water at the reference depth using a local protocol, as developed at different centers, was verified. The measurements were found in good agreement with alanine/EPR dosimetry. The

  10. Entanglement detection with bounded reference frames

    International Nuclear Information System (INIS)

    Costa, Fabio; Brukner, Caslav; Harrigan, Nicholas; Rudolph, Terry

    2009-01-01

    Quantum experiments usually assume the existence of perfect, classical reference frames (RFs), which allow for the specification of measurement settings (e.g. orientation of the Stern-Gerlach magnet in spin measurements) with arbitrary precision. If the RFs are 'bounded' (i.e. quantum systems themselves, having a finite number of degrees of freedom), only limited precision can be attained. Using spin coherent states as bounded RFs, we have found the minimum size needed for them to violate local realism for entangled spin systems. For composite systems of spin 1/2 particles, RFs of very small size are sufficient for the violation; however, to see this violation for macroscopic entangled spins, the size of the RF must be at least quadratically larger than that of the spins. The unavailability of such RFs gives a possible explanation for the non-observance of violation of local realism in everyday experience.

  11. A quasiparticle-based multi-reference coupled-cluster method.

    Science.gov (United States)

    Rolik, Zoltán; Kállay, Mihály

    2014-10-07

    The purpose of this paper is to introduce a quasiparticle-based multi-reference coupled-cluster (MRCC) approach. The quasiparticles are introduced via a unitary transformation which allows us to represent a complete active space reference function and other elements of an orthonormal multi-reference (MR) basis in a determinant-like form. The quasiparticle creation and annihilation operators satisfy the fermion anti-commutation relations. On the basis of these quasiparticles, a generalization of the normal-ordered operator products for the MR case can be introduced as an alternative to the approach of Mukherjee and Kutzelnigg [Recent Prog. Many-Body Theor. 4, 127 (1995); Mukherjee and Kutzelnigg, J. Chem. Phys. 107, 432 (1997)]. Based on the new normal ordering any quasiparticle-based theory can be formulated using the well-known diagram techniques. Beyond the general quasiparticle framework we also present a possible realization of the unitary transformation. The suggested transformation has an exponential form where the parameters, holding exclusively active indices, are defined in a form similar to the wave operator of the unitary coupled-cluster approach. The definition of our quasiparticle-based MRCC approach strictly follows the form of the single-reference coupled-cluster method and retains several of its beneficial properties. Test results for small systems are presented using a pilot implementation of the new approach and compared to those obtained by other MR methods.

  12. Nationwide Multicenter Reference Interval Study for 28 Common Biochemical Analytes in China.

    Science.gov (United States)

    Xia, Liangyu; Chen, Ming; Liu, Min; Tao, Zhihua; Li, Shijun; Wang, Liang; Cheng, Xinqi; Qin, Xuzhen; Han, Jianhua; Li, Pengchang; Hou, Li'an; Yu, Songlin; Ichihara, Kiyoshi; Qiu, Ling

    2016-03-01

    A nationwide multicenter study was conducted in the China to explore sources of variation of reference values and establish reference intervals for 28 common biochemical analytes, as a part of the International Federation of Clinical Chemistry and Laboratory Medicine, Committee on Reference Intervals and Decision Limits (IFCC/C-RIDL) global study on reference values. A total of 3148 apparently healthy volunteers were recruited in 6 cities covering a wide area in China. Blood samples were tested in 2 central laboratories using Beckman Coulter AU5800 chemistry analyzers. Certified reference materials and value-assigned serum panel were used for standardization of test results. Multiple regression analysis was performed to explore sources of variation. Need for partition of reference intervals was evaluated based on 3-level nested ANOVA. After secondary exclusion using the latent abnormal values exclusion method, reference intervals were derived by a parametric method using the modified Box-Cox formula. Test results of 20 analytes were made traceable to reference measurement procedures. By the ANOVA, significant sex-related and age-related differences were observed in 12 and 12 analytes, respectively. A small regional difference was observed in the results for albumin, glucose, and sodium. Multiple regression analysis revealed BMI-related changes in results of 9 analytes for man and 6 for woman. Reference intervals of 28 analytes were computed with 17 analytes partitioned by sex and/or age. In conclusion, reference intervals of 28 common chemistry analytes applicable to Chinese Han population were established by use of the latest methodology. Reference intervals of 20 analytes traceable to reference measurement procedures can be used as common reference intervals, whereas others can be used as the assay system-specific reference intervals in China.

  13. Refer-To-Pharmacy: Pharmacy for the Next Generation Now! A Short Communication for Pharmacy

    Directory of Open Access Journals (Sweden)

    Alistair Gray

    2015-12-01

    Full Text Available Refer-to-Pharmacy is the first fully integrated hospital to community pharmacy referral system. This article explains the importance of these referrals for patients and health economies to improve medicines optimisation, and how Refer-to-Pharmacy works in both hospital and community pharmacies.

  14. Knowledge Management and Reference Services

    Science.gov (United States)

    Gandhi, Smiti

    2004-01-01

    Many corporations are embracing knowledge management (KM) to capture the intellectual capital of their employees. This article focuses on KM applications for reference work in libraries. It defines key concepts of KM, establishes a need for KM for reference services, and reviews various KM initiatives for reference services.

  15. OWL references in ORM conceptual modelling

    Science.gov (United States)

    Matula, Jiri; Belunek, Roman; Hunka, Frantisek

    2017-07-01

    Object Role Modelling methodology is the fact-based type of conceptual modelling. The aim of the paper is to emphasize a close connection to OWL documents and its possible mutual cooperation. The definition of entities or domain values is an indispensable part of the conceptual schema design procedure defined by the ORM methodology. Many of these entities are already defined in OWL documents. Therefore, it is not necessary to declare entities again, whereas it is possible to utilize references from OWL documents during modelling of information systems.

  16. Biomedical Engineering Desk Reference

    CERN Document Server

    Ratner, Buddy D; Schoen, Frederick J; Lemons, Jack E; Dyro, Joseph; Martinsen, Orjan G; Kyle, Richard; Preim, Bernhard; Bartz, Dirk; Grimnes, Sverre; Vallero, Daniel; Semmlow, John; Murray, W Bosseau; Perez, Reinaldo; Bankman, Isaac; Dunn, Stanley; Ikada, Yoshito; Moghe, Prabhas V; Constantinides, Alkis

    2009-01-01

    A one-stop Desk Reference, for Biomedical Engineers involved in the ever expanding and very fast moving area; this is a book that will not gather dust on the shelf. It brings together the essential professional reference content from leading international contributors in the biomedical engineering field. Material covers a broad range of topics including: Biomechanics and Biomaterials; Tissue Engineering; and Biosignal Processing* A hard-working desk reference providing all the essential material needed by biomedical and clinical engineers on a day-to-day basis * Fundamentals, key techniques,

  17. IFCC primary reference procedures for the measurement of catalytic activity concentrations of enzymes at 37 °C. Part 9: reference procedure for the measurement of catalytic concentration of alkaline phosphatase International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) Scientific Division, Committee on Reference Systems of Enzymes (C-RSE) (1)).

    Science.gov (United States)

    Schumann, Gerhard; Klauke, Rainer; Canalias, Francesca; Bossert-Reuther, Steffen; Franck, Paul F H; Gella, F-Javier; Jørgensen, Poul J; Kang, Dongchon; Lessinger, Jean-Marc; Panteghini, Mauro; Ceriotti, Ferruccio

    2011-09-01

    Abstract This paper is the ninth in a series dealing with reference procedures for the measurement of catalytic activity concentrations of enzymes at 37 °C and the certification of reference preparations. Other parts deal with: Part 1. The concept of reference procedures for the measurement of catalytic activity concentrations of enzymes; Part 2. Reference procedure for the measurement of catalytic concentration of creatine kinase; Part 3. Reference procedure for the measurement of catalytic concentration of lactate dehydrogenase; Part 4. Reference procedure for the measurement of catalytic concentration of alanine aminotransferase; Part 5. Reference procedure for the measurement of catalytic concentration of aspartate aminotransferase; Part 6. Reference procedure for the measurement of catalytic concentration of γ-glutamyltransferase; Part 7. Certification of four reference materials for the determination of enzymatic activity of γ-glutamyltransferase, lactate dehydrogenase, alanine aminotransferase and creatine kinase at 37 °C; Part 8. Reference procedure for the measurement of catalytic concentration of α-amylase. The procedure described here is derived from the previously described 30 °C IFCC reference method. Differences are tabulated and commented on in Appendix 1.

  18. Survey of reference materials. V. 2: Environmentally related reference materials for trace elements, nuclides and microcontaminants

    International Nuclear Information System (INIS)

    1996-05-01

    The present report presently contains over 250 reference materials with trace element and organic contaminant information on fuel, geological and mineral, anthropogenic disposal, soil reference and miscellaneous reference materials. Not included in the current report is information on most biological and environmental reference materials with trace element, stable isotope, radioisotope and organic contaminant information. 8 refs, tabs

  19. 32 CFR 634.2 - References.

    Science.gov (United States)

    2010-07-01

    ... 32 National Defense 4 2010-07-01 2010-07-01 true References. 634.2 Section 634.2 National Defense Department of Defense (Continued) DEPARTMENT OF THE ARMY (CONTINUED) LAW ENFORCEMENT AND CRIMINAL INVESTIGATIONS MOTOR VEHICLE TRAFFIC SUPERVISION Introduction § 634.2 References. Required and related publications along with prescribed and reference...

  20. A survey of reference electrodes for high temperature waters; Oeversikt av referenselektroder i hoegtemperaturvatten

    Energy Technology Data Exchange (ETDEWEB)

    Molander, A.; Eriksson, Sture; Pein, K. [Studsvik Nuclear, Nykoeping (Sweden)

    2000-11-01

    In nuclear power plants, corrosion potential measurements are used to follow the conditions for different corrosion types in reactor systems, particularly IGSCC in BWRs. The goal of this work has been to give a survey of reference electrodes for high temperature water, both those that are used for nuclear environments and those that are judged to possible future development. The reference electrodes that are used today in nuclear power plants for corrosion potential measurements are of three types. Silver chloride electrodes, membrane electrodes and platinum electrodes (hydrogen electrodes). The principals for their function is described as well as the conversion of measured potentials to the SHE scale (Standard Hydrogen Electrode). Silver chloride electrodes consist of an inner reference system of silver chloride in equilibrium with a chloride solution. The silver chloride electrode is the most common reference electrode and can be used in several different systems. Platinum electrodes are usually more robust and are particularly suitable to use in BWR environment to follow the hydrogen dosage, but have limitations at low and no hydrogen dosage. Ceramic membrane electrodes can be with different types of internal reference system. They were originally developed for pH measurements in high temperature water. If pH is constant, the membrane electrode can be used as reference electrode. A survey of ceramic reference electrodes for high temperature water is given. A ceramic membrane of the type used works as an oxygen conductor, so the potential and pH in surrounding medium is in equilibrium with the internal reference system. A survey of the lately development of electrodes is presented in order to explain why the different types of electrodes are developed as well as to give a background to the possibilities and limitations with the different electrodes. Possibilities of future development of electrodes are also given. For measurements at low or no hydrogen dosage

  1. Accuracy of Referring Provider and Endoscopist Impressions of Colonoscopy Indication.

    Science.gov (United States)

    Naveed, Mariam; Clary, Meredith; Ahn, Chul; Kubiliun, Nisa; Agrawal, Deepak; Cryer, Byron; Murphy, Caitlin; Singal, Amit G

    2017-07-01

    Background: Referring provider and endoscopist impressions of colonoscopy indication are used for clinical care, reimbursement, and quality reporting decisions; however, the accuracy of these impressions is unknown. This study assessed the sensitivity, specificity, positive and negative predictive value, and overall accuracy of methods to classify colonoscopy indication, including referring provider impression, endoscopist impression, and administrative algorithm compared with gold standard chart review. Methods: We randomly sampled 400 patients undergoing a colonoscopy at a Veterans Affairs health system between January 2010 and December 2010. Referring provider and endoscopist impressions of colonoscopy indication were compared with gold-standard chart review. Indications were classified into 4 mutually exclusive categories: diagnostic, surveillance, high-risk screening, or average-risk screening. Results: Of 400 colonoscopies, 26% were performed for average-risk screening, 7% for high-risk screening, 26% for surveillance, and 41% for diagnostic indications. Accuracy of referring provider and endoscopist impressions of colonoscopy indication were 87% and 84%, respectively, which were significantly higher than that of the administrative algorithm (45%; P 90%) for determining screening (vs nonscreening) indication, but specificity of the administrative algorithm was lower (40.3%) compared with referring provider (93.7%) and endoscopist (84.0%) impressions. Accuracy of endoscopist, but not referring provider, impression was lower in patients with a family history of colon cancer than in those without (65% vs 84%; P =.001). Conclusions: Referring provider and endoscopist impressions of colonoscopy indication are both accurate and may be useful data to incorporate into algorithms classifying colonoscopy indication. Copyright © 2017 by the National Comprehensive Cancer Network.

  2. An overview of digital reference services

    OpenAIRE

    Hemnani, Anita

    2009-01-01

    Digital reference service is an emerging trend of traditional reference service. Easily accessible digital reference service has become one of the hallmark of the library and information services. The paper highlights how new visage of traditional reference service is developing as a natural solution to keep pace with comprehensive technological environment. It discusses about the basic concepts, elements of digital reference service and give in detail modes, the advantages, limitations, and...

  3. Generic Crystalline Disposal Reference Case

    Energy Technology Data Exchange (ETDEWEB)

    Painter, Scott Leroy [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Chu, Shaoping [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Harp, Dylan Robert [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Perry, Frank Vinton [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Wang, Yifeng [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2015-02-20

    A generic reference case for disposal of spent nuclear fuel and high-level radioactive waste in crystalline rock is outlined. The generic cases are intended to support development of disposal system modeling capability by establishing relevant baseline conditions and parameters. Establishment of a generic reference case requires that the emplacement concept, waste inventory, waste form, waste package, backfill/buffer properties, EBS failure scenarios, host rock properties, and biosphere be specified. The focus in this report is on those elements that are unique to crystalline disposal, especially the geosphere representation. Three emplacement concepts are suggested for further analyses: a waste packages containing 4 PWR assemblies emplaced in boreholes in the floors of tunnels (KBS-3 concept), a 12-assembly waste package emplaced in tunnels, and a 32-assembly dual purpose canister emplaced in tunnels. In addition, three failure scenarios were suggested for future use: a nominal scenario involving corrosion of the waste package in the tunnel emplacement concepts, a manufacturing defect scenario applicable to the KBS-3 concept, and a disruptive glaciation scenario applicable to both emplacement concepts. The computational approaches required to analyze EBS failure and transport processes in a crystalline rock repository are similar to those of argillite/shale, with the most significant difference being that the EBS in a crystalline rock repository will likely experience highly heterogeneous flow rates, which should be represented in the model. The computational approaches required to analyze radionuclide transport in the natural system are very different because of the highly channelized nature of fracture flow. Computational workflows tailored to crystalline rock based on discrete transport pathways extracted from discrete fracture network models are recommended.

  4. Synthesized view comparison method for no-reference 3D image quality assessment

    Science.gov (United States)

    Luo, Fangzhou; Lin, Chaoyi; Gu, Xiaodong; Ma, Xiaojun

    2018-04-01

    We develop a no-reference image quality assessment metric to evaluate the quality of synthesized view rendered from the Multi-view Video plus Depth (MVD) format. Our metric is named Synthesized View Comparison (SVC), which is designed for real-time quality monitoring at the receiver side in a 3D-TV system. The metric utilizes the virtual views in the middle which are warped from left and right views by Depth-image-based rendering algorithm (DIBR), and compares the difference between the virtual views rendered from different cameras by Structural SIMilarity (SSIM), a popular 2D full-reference image quality assessment metric. The experimental results indicate that our no-reference quality assessment metric for the synthesized images has competitive prediction performance compared with some classic full-reference image quality assessment metrics.

  5. Doing the work of reference practical tips for excelling as a reference librarian

    CERN Document Server

    Katz, Linda S

    2013-01-01

    Become more versatile, competent, and resourceful with these practical suggestions!Becoming a first-class reference librarian demands proficiency in a wide range of skills. Doing the Work of Reference offers sound advice for the full spectrum of your responsibilities. Though many aspects of a reference librarian's work are changing with astonishing speed, the classic principles in this volume will never go out of date. This comprehensive volume begins with hints for orienting yourself to a new job and concludes with ideas for serving the profession. On the way, Doing the Wo

  6. Use of gamma spectrometry for analysis of three reference materials

    International Nuclear Information System (INIS)

    Kinova, L.

    2004-01-01

    All reference materials (Reference material A: weight = 49.23 g; Reference material B: weight = 36.08 g; Reference material C: weight = 26.18 g) were packed in 50 cm 3 polypropylene vials, sealed and measured consecutively three times at intervals of the average of 25 days. Low background gamma spectrometry system: HPGe detector with high energy resolution (FWHM for 1332 KeV of Co-60 is 1.9 KeV, Relative counting efficiency for the same energy is 21 %) was used. Results: All materials are of low activity and must be measured for a long time.The highest specific activity of a man-made radionuclides Cs-137 and Am-241 is in the material A. An instrumentally measurable activity of Pb-210 also can be observed in this material. Medium values are in the material B. The reference material C according to the specific activity seems to be a low natural radioactivity material with highest activity of natural nuclides Th-232 and Pa-234 (progeny of U-238). Conclusions: Gamma spectrometry is an useful tool for initial measurement of materials with low radioactivity. Such measurements give an orientation for the nuclides content and approximate activity in the material for the following radiochemical determinations

  7. 2002 reference document

    International Nuclear Information System (INIS)

    2002-01-01

    This 2002 reference document of the group Areva, provides information on the society. Organized in seven chapters, it presents the persons responsible for the reference document and for auditing the financial statements, information pertaining to the transaction, general information on the company and share capital, information on company operation, changes and future prospects, assets, financial position, financial performance, information on company management and executive board and supervisory board, recent developments and future prospects. (A.L.B.)

  8. Fundamentals of Managing Reference Collections

    Science.gov (United States)

    Singer, Carol A.

    2012-01-01

    Whether a library's reference collection is large or small, it needs constant attention. Singer's book offers information and insight on best practices for reference collection management, no matter the size, and shows why managing without a plan is a recipe for clutter and confusion. In this very practical guide, reference librarians will learn:…

  9. Structure factor of liquid alkali metals using a classical-plasma reference system

    Science.gov (United States)

    Pastore, G.; Tosi, M. P.

    1984-06-01

    This paper presents calculations of the liquid structure factor of the alkali metals near freezing, starting from the classical plasma of bare ions as reference liquid. The indirect ion-ion interaction arising from electronic screening is treated by an optimized random phase approximation (ORPA), imposing physical requirements as in the original ORPA scheme developed by Weeks, Chandler and Andersen for liquids with strongly repulsive core potentials. A comparison of the results with computer simulation data for a model of liquid rubidium shows that the present approach overcomes the well-known difficulties met in applying to these metals the standard ORPA based on a reference liquid of neutral hard spheres. The optimization scheme is also shown to be equivalent to a reduction of the range of the indirect interaction in momentum space, as proposed empirically in an earlier work. Comparison with experiment for the other alkalis shows that a good overall representation of the data can be obtained for sodium, potassium and cesium, but not for lithium, when one uses a very simple form of the electron-ion potential adjusted to the liquid compressibility. The small-angle scattering region is finally examined more carefully in the light of recent data of Waseda, with a view to possible refinements of the pseudopotential model.

  10. Testing the causal theory of reference.

    Science.gov (United States)

    Domaneschi, Filippo; Vignolo, Massimiliano; Di Paola, Simona

    2017-04-01

    Theories of reference are a crucial research topic in analytic philosophy. Since the publication of Kripke's Naming and Necessity, most philosophers have endorsed the causal/historical theory of reference. The goal of this paper is twofold: (i) to discuss a method for testing experimentally the causal theory of reference for proper names by investigating linguistic usage and (ii) to present the results from two experiments conducted with that method. Data collected in our experiments confirm the causal theory of reference for people proper names and for geographical proper names. A secondary but interesting result is that the semantic domain affects reference assignment: while with people proper names speakers tend to assign the semantic reference, with geographical proper names they are prompted to assign the speaker's reference. Copyright © 2016 Elsevier B.V. All rights reserved.

  11. Studies on the aquatic environment at Olkiluoto and reference area. 1: Olkiluoto, reference lakes and Eurajoki and Lapijoki rivers in 2009-2010

    Energy Technology Data Exchange (ETDEWEB)

    Kangasniemi, V. [Environmental Research and Assessment EnviroCase Ltd., Pori (Finland); Helin, J.

    2014-03-15

    This working report presents the first results of a sampling campaign at Olkiluoto and reference lakes and rivers selected to resemble the aquatic systems expected to form at the site in the future with the post-glacial crustal rebound (land uplift). In 2009-2010, the aim of the studies was to improve the knowledge of the aquatic systems and to produce input data to the safety case for the spent nuclear fuel repository at Olkiluoto. The first main objective was to estimate the areal biomass distribution and measure the dimensions of characteristic aquatic plants and animals. Another objective was to estimate the transfer of different elements from water to the aquatic organisms paying special attention on key elements (Ag, Cl, I, Mo, Nb and Se) in the dose assessment within the safety case. Surface water, sediment, macrophyte, fish and macrobenthos samples were collected from the Olkiluoto coastal area and from the reference lakes for biomass and dimension measurements and analysis of element concentration. Water-to-biota concentration ratios were estimated for the coastal area and for the reference lakes. From rivers, only water samples were collected at this stage. In 2009-2010, sampling procedures and pre-treatment methods were developed and analytical methods were optimised. Thus, the results reported here are indicative by their nature. After 2010, the studies have been continued with better established methods, and the more recent results will be reported later. (orig.)

  12. Procedure and reference standard to determine the structural resolution in coordinate metrology

    Science.gov (United States)

    Illemann, Jens; Bartscher, Markus; Jusko, Otto; Härtig, Frank; Neuschaefer-Rube, Ulrich; Wendt, Klaus

    2014-06-01

    A new procedure and reference standards for specifying the structural resolution in coordinate metrology traceable to the SI unit the metre are proposed. With the definition of the structural resolution, a significant gap will be closed to complete ‘acceptance and verification tests’ of the coordinate measuring systems (CMSs) which are specified in the ISO 10360 series dealing with tactile sensors, optical sensors, and x-ray computed tomography measurement systems (CTs). The proposed new procedure uses reference standards with circular rounded edges. The idea is to measure the radius of curvature on a calibrated round edge structure. From the deviation between the measured and the calibrated radius, an analogue Gaussian broadening of the measurement system is determined. This value is a well-defined and easy-to-apply measure to define the structural resolution for dimensional measurements. It is applicable to CMSs which are based on different sensing principles, e.g. tactile, optical and CT systems. On the other hand, it has a physical meaning similar to the classical optical point-spread function. It makes it possible to predict which smallest details the CMS is capable of measuring reliably for an arbitrary object shape. The theoretical background of the new procedure is given, an appropriate reference standard is described and comparative, quantitative measurement data of CMSs featuring different sensors are shown.

  13. Reference Value Advisor: a new freeware set of macroinstructions to calculate reference intervals with Microsoft Excel.

    Science.gov (United States)

    Geffré, Anne; Concordet, Didier; Braun, Jean-Pierre; Trumel, Catherine

    2011-03-01

    International recommendations for determination of reference intervals have been recently updated, especially for small reference sample groups, and use of the robust method and Box-Cox transformation is now recommended. Unfortunately, these methods are not included in most software programs used for data analysis by clinical laboratories. We have created a set of macroinstructions, named Reference Value Advisor, for use in Microsoft Excel to calculate reference limits applying different methods. For any series of data, Reference Value Advisor calculates reference limits (with 90% confidence intervals [CI]) using a nonparametric method when n≥40 and by parametric and robust methods from native and Box-Cox transformed values; tests normality of distributions using the Anderson-Darling test and outliers using Tukey and Dixon-Reed tests; displays the distribution of values in dot plots and histograms and constructs Q-Q plots for visual inspection of normality; and provides minimal guidelines in the form of comments based on international recommendations. The critical steps in determination of reference intervals are correct selection of as many reference individuals as possible and analysis of specimens in controlled preanalytical and analytical conditions. Computing tools cannot compensate for flaws in selection and size of the reference sample group and handling and analysis of samples. However, if those steps are performed properly, Reference Value Advisor, available as freeware at http://www.biostat.envt.fr/spip/spip.php?article63, permits rapid assessment and comparison of results calculated using different methods, including currently unavailable methods. This allows for selection of the most appropriate method, especially as the program provides the CI of limits. It should be useful in veterinary clinical pathology when only small reference sample groups are available. ©2011 American Society for Veterinary Clinical Pathology.

  14. Neptunium: a bibliographic reference

    International Nuclear Information System (INIS)

    Mosley, R.E.

    1979-06-01

    A comprehensive bibliograhy of the literature on the element neptunium published prior to January 1976 is presented. A short abstract is given for each listed reference, with a few exceptions. The references are divided into sections categorized as General, Man-Made Sources (Reactors), Man-Made Sources (Fuel Reprocessing), Chemistry (Solubility), Chemistry (Compounds), Chemistry (Isotopes), Analyses (Instrumental), Analyses (Chemical), Chemical (Animal), Biological (Effects), Biological (Animal-Metabolism-Retention), Biological (Air Movement), Biological (Human Inhalation), Measurement, and Dosimetry. The bibliography contains author and keyword indexes and was compiled to serve as a quick reference source for neptunium-related work. 184 citations

  15. Regular Expression Pocket Reference

    CERN Document Server

    Stubblebine, Tony

    2007-01-01

    This handy little book offers programmers a complete overview of the syntax and semantics of regular expressions that are at the heart of every text-processing application. Ideal as a quick reference, Regular Expression Pocket Reference covers the regular expression APIs for Perl 5.8, Ruby (including some upcoming 1.9 features), Java, PHP, .NET and C#, Python, vi, JavaScript, and the PCRE regular expression libraries. This concise and easy-to-use reference puts a very powerful tool for manipulating text and data right at your fingertips. Composed of a mixture of symbols and text, regular exp

  16. [Investigation of reference intervals of blood gas and acid-base analysis assays in China].

    Science.gov (United States)

    Zhang, Lu; Wang, Wei; Wang, Zhiguo

    2015-10-01

    To investigate and analyze the upper and lower limits and their sources of reference intervals in blood gas and acid-base analysis assays. The data of reference intervals were collected, which come from the first run of 2014 External Quality Assessment (EQA) program in blood gas and acid-base analysis assays performed by National Center for Clinical Laboratories (NCCL). All the abnormal values and errors were eliminated. Data statistics was performed by SPSS 13.0 and Excel 2007 referring to upper and lower limits of reference intervals and sources of 7 blood gas and acid-base analysis assays, i.e. pH value, partial pressure of carbon dioxide (PCO2), partial pressure of oxygen (PO2), Na+, K+, Ca2+ and Cl-. Values were further grouped based on instrument system and the difference between each group were analyzed. There were 225 laboratories submitting the information on the reference intervals they had been using. The three main sources of reference intervals were National Guide to Clinical Laboratory Procedures [37.07% (400/1 079)], instructions of instrument manufactures [31.23% (337/1 079)] and instructions of reagent manufactures [23.26% (251/1 079)]. Approximately 35.1% (79/225) of the laboratories had validated the reference intervals they used. The difference of upper and lower limits in most assays among 7 laboratories was moderate, both minimum and maximum (i.e. the upper limits of pH value was 7.00-7.45, the lower limits of Na+ was 130.00-156.00 mmol/L), and mean and median (i.e. the upper limits of K+ was 5.04 mmol/L and 5.10 mmol/L, the upper limits of PCO2 was 45.65 mmHg and 45.00 mmHg, 1 mmHg = 0.133 kPa), as well as the difference in P2.5 and P97.5 between each instrument system group. It was shown by Kruskal-Wallis method that the P values of upper and lower limits of all the parameters were lower than 0.001, expecting the lower limits of Na+ with P value 0.029. It was shown by Mann-Whitney that the statistic differences were found among instrument

  17. REFERENCE CASES FOR USE IN THE CEMENTITOUS PARTNERSHIP PROJECT

    Energy Technology Data Exchange (ETDEWEB)

    Langton, C.; Kosson, D.; Garrabrants, A.

    2010-08-31

    The Cementitious Barriers Partnership Project (CBP) is a multi-disciplinary, multi-institution cross cutting collaborative effort supported by the US Department of Energy (DOE) to develop a reasonable and credible set of tools to improve understanding and prediction of the structural, hydraulic and chemical performance of cementitious barriers used in nuclear applications. The period of performance is >100 years for operating facilities and > 1000 years for waste management. The CBP has defined a set of reference cases to provide the following functions: (i) a common set of system configurations to illustrate the methods and tools developed by the CBP, (ii) a common basis for evaluating methodology for uncertainty characterization, (iii) a common set of cases to develop a complete set of parameter and changes in parameters as a function of time and changing conditions, (iv) a basis for experiments and model validation, and (v) a basis for improving conceptual models and reducing model uncertainties. These reference cases include the following two reference disposal units and a reference storage unit: (i) a cementitious low activity waste form in a reinforced concrete disposal vault, (ii) a concrete vault containing a steel high-level waste tank filled with grout (closed high-level waste tank), and (iii) a spent nuclear fuel basin during operation. Each case provides a different set of desired performance characteristics and interfaces between materials and with the environment. Examples of concretes, grout fills and a cementitious waste form are identified for the relevant reference case configurations.

  18. REFERENCE CASES FOR USE IN THE CEMENTITIOUS BARRIERS PARTNERSHIP

    Energy Technology Data Exchange (ETDEWEB)

    Langton, C

    2009-01-06

    The Cementitious Barriers Project (CBP) is a multidisciplinary cross cutting project initiated by the US Department of Energy (DOE) to develop a reasonable and credible set of tools to improve understanding and prediction of the structural, hydraulic and chemical performance of cementitious barriers used in nuclear applications. The period of performance is >100 years for operating facilities and > 1000 years for waste management. The CBP has defined a set of reference cases to provide the following functions: (1) a common set of system configurations to illustrate the methods and tools developed by the CBP, (2) a common basis for evaluating methodology for uncertainty characterization, (3) a common set of cases to develop a complete set of parameter and changes in parameters as a function of time and changing conditions, and (4) a basis for experiments and model validation, and (5) a basis for improving conceptual models and reducing model uncertainties. These reference cases include the following two reference disposal units and a reference storage unit: (1) a cementitious low activity waste form in a reinforced concrete disposal vault, (2) a concrete vault containing a steel high-level waste tank filled with grout (closed high-level waste tank), and (3) a spent nuclear fuel basin during operation. Each case provides a different set of desired performance characteristics and interfaces between materials and with the environment. Examples of concretes, grout fills and a cementitious waste form are identified for the relevant reference case configurations.

  19. REFERENCE CASES FOR USE IN THE CEMENTITOUS PARTNERSHIP PROJECT

    International Nuclear Information System (INIS)

    Langton, C.; Kosson, D.; Garrabrants, A.

    2010-01-01

    The Cementitious Barriers Partnership Project (CBP) is a multi-disciplinary, multi-institution cross cutting collaborative effort supported by the US Department of Energy (DOE) to develop a reasonable and credible set of tools to improve understanding and prediction of the structural, hydraulic and chemical performance of cementitious barriers used in nuclear applications. The period of performance is >100 years for operating facilities and > 1000 years for waste management. The CBP has defined a set of reference cases to provide the following functions: (i) a common set of system configurations to illustrate the methods and tools developed by the CBP, (ii) a common basis for evaluating methodology for uncertainty characterization, (iii) a common set of cases to develop a complete set of parameter and changes in parameters as a function of time and changing conditions, (iv) a basis for experiments and model validation, and (v) a basis for improving conceptual models and reducing model uncertainties. These reference cases include the following two reference disposal units and a reference storage unit: (i) a cementitious low activity waste form in a reinforced concrete disposal vault, (ii) a concrete vault containing a steel high-level waste tank filled with grout (closed high-level waste tank), and (iii) a spent nuclear fuel basin during operation. Each case provides a different set of desired performance characteristics and interfaces between materials and with the environment. Examples of concretes, grout fills and a cementitious waste form are identified for the relevant reference case configurations.

  20. Optimized Flow Sheet for a Reference Commercial-Scale Nuclear-Driven High-Temperature Electrolysis Hydrogen Production Plant

    International Nuclear Information System (INIS)

    M. G. McKellar; J. E. O'Brien; E. A. Harvego; J. S. Herring

    2007-01-01

    This report presents results from the development and optimization of a reference commercial scale high-temperature electrolysis (HTE) plant for hydrogen production. The reference plant design is driven by a high-temperature helium-cooled reactor coupled to a direct Brayton power cycle. The reference design reactor power is 600 MWt, with a primary system pressure of 7.0 MPa, and reactor inlet and outlet fluid temperatures of 540 C and 900 C, respectively. The electrolysis unit used to produce hydrogen consists of 4.176 - 10 6 cells with a per-cell active area of 225 cm2. A nominal cell area-specific resistance, ASR, value of 0.4 Ohm-cm2 with a current density of 0.25 A/cm2 was used, and isothermal boundary conditions were assumed. The optimized design for the reference hydrogen production plant operates at a system pressure of 5.0 MPa, and utilizes an air-sweep system to remove the excess oxygen that is evolved on the anode side of the electrolyzer. The inlet air for the air-sweep system is compressed to the system operating pressure of 5.0 MPa in a four-stage compressor with intercooling. The overall system thermal-to-hydrogen production efficiency (based on the low heating value of the produced hydrogen) is 49.07% at a hydrogen production rate of 2.45 kg/s with the high-temperature helium-cooled reactor concept. The information presented in this report is intended to establish an optimized design for the reference nuclear-driven HTE hydrogen production plant so that parameters can be compared with other hydrogen production methods and power cycles to evaluate relative performance characteristics and plant economics

  1. Java for dummies quick reference

    CERN Document Server

    Lowe, Doug

    2012-01-01

    A reference that answers your questions as you move through your coding The demand for Android programming and web apps continues to grow at an unprecedented pace and Java is the preferred language for both. Java For Dummies Quick Reference keeps you moving through your coding while you solve a problem, look up a command or syntax, or search for a programming tip. Whether you're a Java newbie or a seasoned user, this fast reference offers you quick access to solutions without requiring that you wade through pages of tutorial material. Leverages the true reference format that is organized with

  2. Improving the Lane Reference Detection for Autonomous Road Vehicle Control

    Directory of Open Access Journals (Sweden)

    Felipe Jiménez

    2016-01-01

    Full Text Available Autonomous road vehicles are increasingly becoming more important and there are several techniques and sensors that are being applied for vehicle control. This paper presents an alternative system for maintaining the position of autonomous vehicles without adding additional elements to the standard sensor architecture, by using a 3D laser scanner for continuously detecting a reference element in situations in which the GNSS receiver fails or provides accuracy below the required level. Considering that the guidance variables are more accurately estimated when dealing with reference points in front of and behind the vehicle, an algorithm based on vehicle dynamics mathematical model is proposed to extend the detected points in cases where the sensor is placed at the front of the vehicle. The algorithm has been tested when driving along a lane delimited by New Jersey barriers at both sides and the results show a correct behaviour. The system is capable of estimating the reference element behind the vehicle with sufficient accuracy when the laser scanner is placed at the front of it, so the robustness of the control input variables (lateral and angular errors estimation is improved making it unnecessary to place the sensor on the vehicle roof or to introduce additional sensors.

  3. Optimal primitive reference frames

    International Nuclear Information System (INIS)

    Jennings, David

    2011-01-01

    We consider the smallest possible directional reference frames allowed and determine the best one can ever do in preserving quantum information in various scenarios. We find that for the preservation of a single spin state, two orthogonal spins are optimal primitive reference frames; and in a product state, they do approximately 22% as well as an infinite-sized classical frame. By adding a small amount of entanglement to the reference frame, this can be raised to 2(2/3) 5 =26%. Under the different criterion of entanglement preservation, a very similar optimal reference frame is found; however, this time it is for spins aligned at an optimal angle of 87 deg. In this case 24% of the negativity is preserved. The classical limit is considered numerically, and indicates under the criterion of entanglement preservation, that 90 deg. is selected out nonmonotonically, with a peak optimal angle of 96.5 deg. for L=3 spins.

  4. Weather Test Reference Year of Greenland

    DEFF Research Database (Denmark)

    Kragh, Jesper; Pedersen, Frank; Svendsen, Svend

    2005-01-01

    the construction of two test reference years of Greenland used in the work of establishing new energy frame for the coming building code of Greenland. The first test reference year is constructed using measurements of climatic parameters from the town Nuuk located in the southwestern part of Greenland. The second...... test reference year is constructed using measurements from the town Uummannaq located in the north part of Greenland on the west coast. The construction of the test reference years fulfills the procedures described in the standard EN ISO 15927-4 using the following main weather parameters: Dry bulb...... temperature, global radiation, relative humidity and mean wind speed. To construct the test reference years a program called REFYEAR was developed in MatLab. REFYEAR automatically constructs the test reference year using an input file containing the climatic measurements. The two constructed test reference...

  5. Multipass Steering: A Reference Implementation

    Science.gov (United States)

    Hennessey, Michael; Tiefenback, Michael

    2015-10-01

    We introduce a reference implementation of a protocol to compute corrections that bring all beams in one of the CEBAF linear accelerators (linac) to axis, including, with a larger tolerance, the lowest energy pass using measured beam trajectory data. This method relies on linear optics as representation of the system; we treat beamline perturbations as magnetic field errors localized to regions between cryomodules, providing the same transverse momentum kick to each beam. We produce a vector of measured beam position data with which we left-multiply the pseudo-inverse of a coefficient array, A, that describes the transport of the beam through the linac using parameters that include the magnetic offsets of the quadrupole magnets, the instrumental offsets of the BPMs, and the beam initial conditions. This process is repeated using a reduced array to produce values that can be applied to the available correcting magnets and beam initial conditions. We show that this method is effective in steering the beam to a straight axis along the linac by using our values in elegant, the accelerator simulation program, on a model of the linac in question. The algorithms in this reference implementation provide a tool for systematic diagnosis and cataloging of perturbations in the beam line. Supported by Jefferson Lab, Old Dominion University, NSF, DOE.

  6. Content Analysis of Virtual Reference Data: Reshaping Library Website Design.

    Science.gov (United States)

    Fan, Suhua Caroline; Welch, Jennifer M

    2016-01-01

    An academic health sciences library wanted to redesign its website to provide better access to health information in the community. Virtual reference data were used to provide information about user searching behavior. This study analyzed three years (2012-2014) of virtual reference data, including e-mail questions, text messaging, and live chat transcripts, to evaluate the library website for redesigning, especially in areas such as the home page, patrons' terminology, and issues prompting patrons to ask for help. A coding system based on information links in the current library website was created to analyze the data.

  7. Blind Synchronization in Asynchronous UWB Networks Based on the Transmit-Reference Scheme

    NARCIS (Netherlands)

    Djapic, R.; Leus, G.; Van Der Veen, A.J.; Trinda, A.

    2006-01-01

    Ultra-wideband (UWB) wireless communication systems are based on the transmission of extremely narrow pulses, with a duration inferior to a nanosecond. The application of transmit reference (TR) to UWB systems allows to side-step channel estimation at the receiver, with a tradeoff of the effective

  8. Blind synchronization in asynchronous UWB networks based on the transmit-reference scheme

    NARCIS (Netherlands)

    Djapic, R.; Leus, G.; Veen, A.-J. van der; Trindade, A.

    2006-01-01

    Ultra-wideband (UWB) wireless communication systems are based on the transmission of extremely narrow pulses, with a duration inferior to a nanosecond. The application of transmit reference(TR) to UWB systems allows to side-step channel estimation at the receiver, with a tradeoff of the effective

  9. The utility of optical detection system (qPCR) and bioinformatics methods in reference gene expression analysis

    Science.gov (United States)

    Skarzyńska, Agnieszka; Pawełkowicz, Magdalena; PlÄ der, Wojciech; Przybecki, Zbigniew

    2016-09-01

    Real-time quantitative polymerase chain reaction is consider as the most reliable method for gene expression studies. However, the expression of target gene could be misinterpreted due to improper normalization. Therefore, the crucial step for analysing of qPCR data is selection of suitable reference genes, which should be validated experimentally. In order to choice the gene with stable expression in the designed experiment, we performed reference gene expression analysis. In this study genes described in the literature and novel genes predicted as control genes, based on the in silico analysis of transcriptome data were used. Analysis with geNorm and NormFinder algorithms allow to create the ranking of candidate genes and indicate the best reference for flower morphogenesis study. According to the results, genes CACS and CYCL were characterised the most stable expression, but the least suitable genes were TUA and EF.

  10. Can Single-Reference Coupled Cluster Theory Describe Static Correlation?

    Science.gov (United States)

    Bulik, Ireneusz W; Henderson, Thomas M; Scuseria, Gustavo E

    2015-07-14

    While restricted single-reference coupled cluster theory truncated to singles and doubles (CCSD) provides very accurate results for weakly correlated systems, it usually fails in the presence of static or strong correlation. This failure is generally attributed to the qualitative breakdown of the reference, and can accordingly be corrected by using a multideterminant reference, including higher-body cluster operators in the ansatz, or allowing symmetry breaking in the reference. None of these solutions are ideal; multireference coupled cluster is not black box, including higher-body cluster operators is computationally demanding, and allowing symmetry breaking leads to the loss of good quantum numbers. It has long been recognized that quasidegeneracies can instead be treated by modifying the coupled cluster ansatz. The recently introduced pair coupled cluster doubles (pCCD) approach is one such example which avoids catastrophic failures and accurately models strong correlations in a symmetry-adapted framework. Here, we generalize pCCD to a singlet-paired coupled cluster model (CCD0) intermediate between coupled cluster doubles and pCCD, yielding a method that possesses the invariances of the former and much of the stability of the latter. Moreover, CCD0 retains the full structure of coupled cluster theory, including a fermionic wave function, antisymmetric cluster amplitudes, and well-defined response equations and density matrices.

  11. Effect of reference conditions on flow rate, modifier fraction and retention in supercritical fluid chromatography.

    Science.gov (United States)

    De Pauw, Ruben; Shoykhet Choikhet, Konstantin; Desmet, Gert; Broeckhoven, Ken

    2016-08-12

    When using compressible mobile phases such as fluidic CO2, the density, the volumetric flow rates and volumetric fractions are pressure dependent. The pressure and temperature definition of these volumetric parameters (referred to as the reference conditions) may alter between systems, manufacturers and operating conditions. A supercritical fluid chromatography system was modified to operate in two modes with different definition of the eluent delivery parameters, referred to as fixed and variable mode. For the variable mode, the volumetric parameters are defined with reference to the pump operating pressure and actual pump head temperature. These conditions may vary when, e.g. changing the column length, permeability, flow rate, etc. and are thus variable reference conditions. For the fixed mode, the reference conditions were set at 150bar and 30°C, resulting in a mass flow rate and mass fraction of modifier definition which is independent of the operation conditions. For the variable mode, the mass flow rate of carbon dioxide increases with system pump operating pressure, decreasing the fraction of modifier. Comparing the void times and retention factor shows that the deviation between the two modes is almost independent of modifier percentage, but depends on the operating pressure. Recalculating the set volumetric fraction of modifier to the mass fraction results in the same retention behaviour for both modes. This shows that retention in SFC can be best modelled using the mass fraction of modifier. The fixed mode also simplifies method scaling as it only requires matching average column pressure. Copyright © 2016 Elsevier B.V. All rights reserved.

  12. Review of Media Sync Reference Models: Advances and Open Issues

    NARCIS (Netherlands)

    M.A. Montagud Climent (Mario); A.J. Jansen (Jack); P.S. Cesar Garcia (Pablo Santiago); F. Boronat (Fernando); M.A. Montagud Climent (Mario); P.S. Cesar Garcia (Pablo Santiago); F. Boronat (Fernando); H.M. Stokking (Hans)

    2015-01-01

    htmlabstractThe advances on multimedia systems have brought new challenges and requirements for media sync. Over the years, many media sync solutions have been devised. Due to this variety, several studies have surveyed the existing solutions and proposed classification schemes or reference models

  13. Effect of reference loads on fracture mechanics analysis of surface cracked pipe based on reference stress method

    International Nuclear Information System (INIS)

    Shim, Do Jun; Son, Beom Goo; Kim, Young Jin; Kim, Yun Jae

    2004-01-01

    To investigate relevance of the definition of the reference stress to estimate J and C * for surface crack problems, this paper compares FE J and C * results for surface cracked pipes with those estimated according to the reference stress approach using various definitions of the reference stress. Pipes with part circumferential inner surface crack and finite internal axial crack are considered, subject to internal pressure and global bending. The crack depth and aspect ratio are systematically varied. The reference stress is defined in four different ways using (I) the local limit load, (II) the global limit load, (III) the global limit load determined from the FE limit analysis, and (IV) the optimised reference load. It is found that the reference stress based on the local limit load gives overall excessively conservative estimates of J and C * . Use of the global limit load clearly reduces the conservatism, compared to that of the local limit load, although it can provide sometimes non-conservative estimates of J and C * . The use of the FE global limit load gives overall non-conservative estimates of J and C * . The reference stress based on the optimised reference load gives overall accurate estimates of J and C * , compared to other definitions of the reference stress. Based on the present finding, general guidance on the choice of the reference stress for surface crack problems is given

  14. Quality of Standard Reference Materials for Short Time Activation Analysis

    International Nuclear Information System (INIS)

    Ismail, S.S.; Oberleitner, W.

    2003-01-01

    Some environmental reference materials (CFA-1633 b, IAEA-SL-1, SARM-1,BCR-176, Coal-1635, IAEA-SL-3, BCR-146, and SRAM-5) were analysed by short-time activation analysis. The results show that these materials can be classified in three groups, according to their activities after irradiation. The obtained results were compared in order to create a quality index for determination of short-lived nuclides at high count rates. It was found that Cfta is not a suitable standard for determining very short-lived nuclides (half-lives<1 min) because the activity it produces is 15-fold higher than that SL-3. Biological reference materials, such as SRM-1571, SRM-1573, SRM-1575, SRM-1577, IAEA-392, and IAEA-393, were also investigated by a higher counting efficiency system. The quality of this system and its well-type detector for investigating short-lived nuclides was discussed

  15. JavaScript programmer's reference

    CERN Document Server

    Valentine, Thomas

    2013-01-01

    JavaScript Programmer's Reference is an invaluable resource that won't stray far from your desktop (or your tablet!). It contains detailed information on every JavaScript object and command, and combines that reference with practical examples showcasing how you can use those commands in the real world. Whether you're just checking the syntax of a method or you're starting out on the road to JavaScript mastery, the JavaScript Programmer's Reference will be an essential aid.  With a detailed and informative tutorial section giving you the ins and outs of programming with JavaScript and the DOM f

  16. R quick syntax reference

    CERN Document Server

    Tollefson, Margot

    2014-01-01

    The R Quick Syntax Reference is a handy reference book detailing the intricacies of the R language. Not only is R a free, open-source tool, R is powerful, flexible, and has state of the art statistical techniques available. With the many details which must be correct when using any language, however, the R Quick Syntax Reference makes using R easier.Starting with the basic structure of R, the book takes you on a journey through the terminology used in R and the syntax required to make R work. You will find looking up the correct form for an expression quick and easy. With a copy of the R Quick

  17. Recent references May through August 1992

    International Nuclear Information System (INIS)

    Ramavataram, S.

    1992-01-01

    In support of a continuing program of systematic evaluation of nuclear structure data, the National Nuclear Data Center maintains a complete computer file of references to the nuclear physics literature. Each reference is tagged by a keyword string, which indicates the kinds of data contained in the article. This master file of Nuclear Structure References (NSR) contains complete keyword indexes to literature published since 1969, with partial indexing of older references. Listed are Key Numbers and Keywords, a reaction index, and references and secondary sources for the data

  18. Identification and Illustration of Insecure Direct Object References and their Countermeasures

    Science.gov (United States)

    KumarShrestha, Ajay; Singh Maharjan, Pradip; Paudel, Santosh

    2015-03-01

    The insecure direct object reference simply represents the flaws in the system design without the full protection mechanism for the sensitive system resources or data. It basically occurs when the web application developer provides direct access to objects in accordance with the user input. So any attacker can exploit this web vulnerability and gain access to privileged information by bypassing the authorization. The main aim of this paper is to demonstrate the real effect and the identification of the insecure direct object references and then to provide the feasible preventive solutions such that the web applications do not allow direct object references to be manipulated by attackers. The experiment of the insecure direct object referencing is carried out using the insecure J2EE web application called WebGoat and its security testing is being performed using another JAVA based tool called BURP SUITE. The experimental result shows that the access control check for gaining access to privileged information is a very simple problem but at the same time its correct implementation is a tricky task. The paper finally presents some ways to overcome this web vulnerability.

  19. Democracy and environment as references for quadruple and quintuple helix innovation systems

    Science.gov (United States)

    Carayannis, Elias G.; Campbell, David F. J.; Orr, Barron J.

    2015-04-01

    The perspective of democracy and the ecological context define key references for knowledge production and innovation in innovation systems. Particularly under conditions of environmental change where enhancing the potential for adaptation is critical, this requires a closer look at ecological responsibility and sensitivity in the different innovation models and governance regimes. The "Quintuple Helix" innovation model is an approach that stresses the necessary socio-ecological transition of society and economy by adding an environment helix to an innovation system already made up of three (university-industry-government) or four (civil society relations) helices in a way that supports adaptation by incorporating global warming as both a challenge to and a driver of innovation. There is the proposition that knowledge production and innovation co-evolve with democracy (Carayannis and Campbell, 2014). In the Triple Helix model (Etzkowitz and Leydesdorff, 2000) the existence of a democracy does not appear to be necessary for knowledge production and innovation. However, the Quadruple Helix (Carayannis and Campbell, 2009, 2010 and 2014) is defined and represented by additional key attributes and components: "media-based and culture-based public", "civil society" and "arts, artistic research and arts-based innovation" (Bast, Carayannis and Campbell, 2015). Implications of this are that the fourth helix in the Quadruple Helix innovation systems brings in and represents the perspective of "dimension of democracy" or the "context of democracy" for knowledge in general and knowledge production and innovation in more particular. Within theories of democracy there is a competition between narrow and broader concepts of democracy (Campbell, 2013). This is particularly true when democracy is to be understood to transcend more substantially the narrow understanding of being primarily based on or being primarily rooted in government institutions (within a Triple Helix

  20. Dosimetric verification for radiotherapy quality audit under reference and non-reference conditions in Jiangsu province

    International Nuclear Information System (INIS)

    Wang Jin; Yu Ningle; Yang Chunyong; Du Xiang; Chen Wei; Luo Suming

    2014-01-01

    Objective: To verify the methodology for auditing dosimetric parameters in reference and non-reference conditions with thermoluminescent dosimeters (TLDs). Methods: Under reference and non-reference conditions, the established TLD methods were used to observe the absorbed dose variations with depth, SSD, field size and 45 wedges for 10 photon beams at 5 hospitals. Dosimetric parameters, including doses at D_m_a_x points in axis, on 5 electron beams of 9 MeV were measured. The measurement results were compared between the TLDs and plane parallel ionization chambers. Results: For 6 MV photon beams, the relative deviation of between finger ionization chamber method and TLD chips was in the range of -1.7% to 5.4% under on-axis non-reference conditions, and -6.3% to -0.6% under off-axis non-reference conditions, respectively, all within the range of ≤ ±7% as required by the IAEA. The relative deviation between plane parallel chamber and TLD method was -2.3% to 3.7%, within ±5% as required by the IAEA. Conclusions: It is convenient and feasible to use TLD method for quality audits of dosimetric parameters in radiotherapy. (authors)