WorldWideScience

Sample records for reference materials electronic

  1. Electronics engineer's reference book

    CERN Document Server

    Turner, L W

    1976-01-01

    Electronics Engineer's Reference Book, 4th Edition is a reference book for electronic engineers that reviews the knowledge and techniques in electronics engineering and covers topics ranging from basics to materials and components, devices, circuits, measurements, and applications. This edition is comprised of 27 chapters; the first of which presents general information on electronics engineering, including terminology, mathematical equations, mathematical signs and symbols, and Greek alphabet and symbols. Attention then turns to the history of electronics; electromagnetic and nuclear radiatio

  2. Electronics engineer's reference book

    CERN Document Server

    Mazda, F F

    1989-01-01

    Electronics Engineer's Reference Book, Sixth Edition is a five-part book that begins with a synopsis of mathematical and electrical techniques used in the analysis of electronic systems. Part II covers physical phenomena, such as electricity, light, and radiation, often met with in electronic systems. Part III contains chapters on basic electronic components and materials, the building blocks of any electronic design. Part IV highlights electronic circuit design and instrumentation. The last part shows the application areas of electronics such as radar and computers.

  3. Remarks on some reference materials for applications in elastic peak electron spectroscopy

    International Nuclear Information System (INIS)

    Jablonski, A.; Zemek, J.

    2010-01-01

    The quantification of results of electron spectroscopies, AES and XPS, requires knowledge of the inelastic mean free path (IMFP) of signal electrons in solids. This parameter determines the surface sensitivity of both techniques. There are two methods of determining the IMFPs that provide these parameters in agreement with the definition: (1) calculations based on the experimental optical data, and (2) calculations based on measurements of the electron elastic backscattering intensity. The latter method requires the use of some reference material for which the IMFP is known. In 1999, an extensive analysis of the published IMFPs has been performed; the results indicated that there is a very good agreement between the calculated and measured IMFPs for four elemental solids: Ni, Cu, Ag and Au. The averaged IMFPs for these elements are known under the name of the recommended IMFPs. However, no preference among these four elements has been established. In the present work, an attempt is made to select an element for which the recommended IMFPs result in the best agreement between the calculated and measured intensities of elastic electron backscattering. For this purpose, the elastic backscattering intensity has been measured at eight electron energies varying from 200 to 1500 eV. At each energy, the intensity was measured over a wide range of emission angles from 35deg to 74deg. The experiments were accompanied with Monte Carlo calculations of the elastic backscattering probability for the same energies and experimental configurations. It has been found, from comparison, that the best agreement is observed for Au, and this element is thus recommended as the reference material. It has been shown that the shape of the emission angle dependence of the elastic backscattering intensity is noticeably influenced by the surface energy losses. (author)

  4. IAEA biological reference materials

    International Nuclear Information System (INIS)

    Parr, R.M.; Schelenz, R.; Ballestra, S.

    1988-01-01

    The Analytical Quality Control Services programme of the IAEA encompasses a wide variety of intercomparisons and reference materials. This paper reviews only those aspects of the subject having to do with biological reference materials. The 1988 programme foresees 13 new intercomparison exercises, one for major, minor and trace elements, five for radionuclides, and seven for stable isotopes. Twenty-two natural matrix biological reference materials are available: twelve for major, minor and trace elements, six for radionuclides, and four for chlorinated hydrocarbons. Seven new intercomparisons and reference materials are in preparation or under active consideration. Guidelines on the correct use of reference materials are being prepared for publication in 1989 in consultation with other major international producers and users of biological reference materials. The IAEA database on available reference materials is being updated and expanded in scope, and a new publication is planned for 1989. (orig.)

  5. Uranium reference materials

    International Nuclear Information System (INIS)

    Donivan, S.; Chessmore, R.

    1987-07-01

    The Technical Measurements Center has prepared uranium mill tailings reference materials for use by remedial action contractors and cognizant federal and state agencies. Four materials were prepared with varying concentrations of radionuclides, using three tailings materials and a river-bottom soil diluent. All materials were ground, dried, and blended thoroughly to ensure homogeneity. The analyses on which the recommended values for nuclides in the reference materials are based were performed, using independent methods, by the UNC Geotech (UNC) Chemistry Laboratory, Grand Junction, Colorado, and by C.W. Sill (Sill), Idaho National Engineering Laboratory, Idaho Falls, Idaho. Several statistical tests were performed on the analytical data to characterize the reference materials. Results of these tests reveal that the four reference materials are homogeneous and that no large systematic bias exists between the analytical methods used by Sill and those used by TMC. The average values for radionuclides of the two data sets, representing an unbiased estimate, were used as the recommended values for concentrations of nuclides in the reference materials. The recommended concentrations of radionuclides in the four reference materials are provided. Use of these reference materials will aid in providing uniform standardization among measurements made by remedial action contractors. 11 refs., 9 tabs

  6. Critical assessment of the performance of electronic moisture analyzers for small amounts of environmental samples and biological reference materials.

    Science.gov (United States)

    Krachler, M

    2001-12-01

    Two electronic moisture analyzers were critically evaluated with regard to their suitability for determining moisture in small amounts (environmental matrices such as leaves, needles, soil, peat, sediments, and sewage sludge, as well as various biological reference materials. To this end, several homogeneous bulk materials were prepared which were subsequently employed for the development and optimization of all analytical procedures. The key features of the moisture analyzers included a halogen or ceramic heater and an integrated balance with a resolution of 0.1 mg, which is an essential prerequisite for obtaining precise results. Oven drying of the bulk materials in a conventional oven at 105 degrees C until constant mass served as reference method. A heating temperature of 65degrees C was found to provide accurate and precise results for almost all matrices investigated. To further improve the accuracy and precision, other critical parameters such as handling of sample pans, standby temperature, and measurement delay were optimized. Because of its ponderous heating behavior, the performance of the ceramic radiator was inferior to that of the halogen heater, which produced moisture results comparable to those obtained by oven drying. The developed drying procedures were successfully applied to the fast moisture analysis (1.4-6.3 min) of certified biological reference materials of similar provenance to the investigated the bulk materials. Moisture results for 200 mg aliquots ranged from 1.4 to 7.8% and good agreement was obtained between the recommended drying procedure for the reference materials and the electronic moisture analyzers with absolute uncertainties amounting to 0.1% and 0.2-0.3%, respectively.

  7. Radioactive certified reference materials

    International Nuclear Information System (INIS)

    Watanabe, Kazuo

    2010-01-01

    Outline of radioactive certified reference materials (CRM) for the analysis of nuclear materials and radioactive nuclides were described. The nuclear fuel CRMs are supplied by the three institutes: NBL in the US, CETAMA in France and IRMM in Belgium. For the RI CRMs, the Japan Radioisotope Association is engaged in activities concerning supply. The natural-matrix CRMs for the analysis of trace levels of radio-nuclides are prepared and supplied by NIST in the US and the IAEA. (author)

  8. Electronic materials

    CERN Document Server

    Kwok, H L

    2010-01-01

    The electronic properties of solids have become of increasing importance in the age of information technology. The study of solids and materials, while having originated from the disciplines of physics and chemistry, has evolved independently over the past few decades. The classical treatment of solid-state physics, which emphasized classifications, theories and fundamental physical principles, is no longer able to bridge the gap between materials advances and applications. In particular, the more recent developments in device physics and technology have not necessarily been driven by new conc

  9. Uranium tailings reference materials

    International Nuclear Information System (INIS)

    Smith, C.W.; Steger, H.F.; Bowman, W.S.

    1984-01-01

    Samples of uranium tailings from Bancroft and Elliot Lake, Ontario, and from Beaverlodge and Rabbit Lake, Saskatchewan, have been prepared as compositional reference materials at the request of the National Uranium Tailings Research Program. The four samples, UTS-1 to UTS-4, were ground to minus 104 μm, each mixed in one lot and bottled in 200-g units for UTS-1 to UTS-3 and in 100-g units for UTS-4. The materials were tested for homogeneity with respect to uranium by neutron activation analysis and to iron by an acid-decomposition atomic absorption procedure. In a free choice analytical program, 18 laboratories contributed results for one or more of total iron, titanium, aluminum, calcium, barium, uranium, thorium, total sulphur, and sulphate for all four samples, and for nickel and arsenic in UTS-4 only. Based on a statistical analysis of the data, recommended values were assigned to all elements/constituents, except for sulphate in UTS-3 and nickel in UTS-4. The radioactivity of thorium-230, radium-226, lead-210, and polonium-210 in UTS-1 to UTS-4 and of thorium-232, radium-228, and thorium-228 in UTS-1 and UTS-2 was determined in a radioanalytical program composed of eight laboratories. Recommended values for the radioactivities and associated parameters were calculated by a statistical treatment of the results

  10. Electronic Materials Science

    Science.gov (United States)

    Irene, Eugene A.

    2005-02-01

    A thorough introduction to fundamental principles and applications From its beginnings in metallurgy and ceramics, materials science now encompasses such high- tech fields as microelectronics, polymers, biomaterials, and nanotechnology. Electronic Materials Science presents the fundamentals of the subject in a detailed fashion for a multidisciplinary audience. Offering a higher-level treatment than an undergraduate textbook provides, this text benefits students and practitioners not only in electronics and optical materials science, but also in additional cutting-edge fields like polymers and biomaterials. Readers with a basic understanding of physical chemistry or physics will appreciate the text's sophisticated presentation of today's materials science. Instructive derivations of important formulae, usually omitted in an introductory text, are included here. This feature offers a useful glimpse into the foundations of how the discipline understands such topics as defects, phase equilibria, and mechanical properties. Additionally, concepts such as reciprocal space, electron energy band theory, and thermodynamics enter the discussion earlier and in a more robust fashion than in other texts. Electronic Materials Science also features: An orientation towards industry and academia drawn from the author's experience in both arenas Information on applications in semiconductors, optoelectronics, photocells, and nanoelectronics Problem sets and important references throughout Flexibility for various pedagogical needs Treating the subject with more depth than any other introductory text, Electronic Materials Science prepares graduate and upper-level undergraduate students for advanced topics in the discipline and gives scientists in associated disciplines a clear review of the field and its leading technologies.

  11. Nuclear measurements and reference materials

    International Nuclear Information System (INIS)

    1988-01-01

    This report summarizes the progress of the JRC programs on nuclear data, nuclear metrology, nuclear reference materials and non-nuclear reference materials. Budget restrictions and personnel difficulties were encountered during 1987. Fission properties of 235 U as a function of neutron energy and of the resonances can be successfully described on the basis of a three exit channel fission model. Double differential neutron emission cross-sections were accomplished on 7 Li and were started for the tritium production cross-section of 9 Be. Reference materials of uranium minerals and ores were prepared. Special nuclear targets were prepared. A batch of 250 g of Pu0 2 was characterized in view of certification as reference material for the elemental assay of plutonium

  12. Assessment of homogeneity of candidate reference material at the nanogram level and investigation on representativeness of single particle analysis using electron probe X ray microanalysis

    International Nuclear Information System (INIS)

    Ro, Chul-Un; Hoornaerta, S.; Griekena, R. van

    2002-01-01

    Particulate samples of a candidate reference material are evaluated on their homogeneity from bottle to bottle using electron probe X ray microanalysis technique. The evaluation on the homogeneity is done by the utilization of the Kolmogorov-Smirnov statistics to the processing of the quantitative electron probe X ray microanalysis data. Due to a limitation, existing even in computer controlled electron probe X ray microanalysis, in terms of analysis time and expenses, the number of particles analyzed is much smaller compared to that in the sample. Therefore, it is investigated whether this technique provides representative analysis results for the characteristics of the sample, even though a very small portion of the sample is really analyzed. Furthermore, the required number of particles for the analysis, to insure a certain level of reproducibility, e.g. 5% relative standard deviation, is determined by the application of the Ingamells sampling theory. (author)

  13. Modern electronic materials

    CERN Document Server

    Watkins, John B

    2013-01-01

    Modern Electronic Materials focuses on the development of electronic components. The book first discusses the history of electronic components, including early developments up to 1900, developments up to World War II, post-war developments, and a comparison of present microelectric techniques. The text takes a look at resistive materials. Topics include resistor requirements, basic properties, evaporated film resistors, thick film resistors, and special resistors. The text examines dielectric materials. Considerations include basic properties, evaporated dielectric materials, ceramic dielectri

  14. Advances in electronic materials

    CERN Document Server

    Kasper, Erich; Grimmeiss, Hermann G

    2008-01-01

    This special-topic volume, Advances in Electronic Materials, covers various fields of materials research such as silicon, silicon-germanium hetero-structures, high-k materials, III-V semiconductor alloys and organic materials, as well as nano-structures for spintronics and photovoltaics. It begins with a brief summary of the formative years of microelectronics; now the keystone of information technology. The latter remains one of the most important global technologies, and is an extremely complex subject-area. Although electronic materials are primarily associated with computers, the internet

  15. COMAR - database for certified reference materials

    International Nuclear Information System (INIS)

    Klich, H.; Caliste, J.P.

    1988-01-01

    With more than 130 producers of reference materials (RM) throughout the world, it is often difficult to find the best reference material for a specific application. The computer database COMAR has been developed to aid chemists in finding the needed reference material. (orig.)

  16. Reference materials and measurement traceability

    International Nuclear Information System (INIS)

    Bingham, C.D.

    1980-01-01

    Nuclear materials safeguards within the U.S.A. are accomplished by the integration of activities involving physical protection, material control and material accountability. Material accountability requires both sound measurement technology and well-defined accounting procedures to provide final evidence that physical protection and materials control have achieved their purpose. 5 refs

  17. A routine chromium determination in biological materials; application to various reference materials and standard reference materials

    International Nuclear Information System (INIS)

    Tjioe, P.S.; Goeij, J.J.M. de; Volkers, K.J.

    1979-01-01

    The determination limit under standard working conditions of chromium in biological materials is discussed. Neutron activation analysis and atomic spectrometry have been described for some analytical experiences with NBS SRM 1577 reference material. The chromium determination is a part of a larger multi-element scheme for the determination of 12 elements in biological materials

  18. Survey of reference materials. V. 2: Environmentally related reference materials for trace elements, nuclides and microcontaminants

    International Nuclear Information System (INIS)

    1996-05-01

    The present report presently contains over 250 reference materials with trace element and organic contaminant information on fuel, geological and mineral, anthropogenic disposal, soil reference and miscellaneous reference materials. Not included in the current report is information on most biological and environmental reference materials with trace element, stable isotope, radioisotope and organic contaminant information. 8 refs, tabs

  19. Single-particle characterization of 'Asian Dust' certified reference materials using low-Z particle electron probe X-ray microanalysis

    International Nuclear Information System (INIS)

    Hwang, Hee Jin; Ro, Chul-Un

    2006-01-01

    In order to clearly elucidate whether Asian Dust particles experience chemical modification during long-range transport, it is necessary to characterize soil particles where Asian Dust particles originate. If chemical compositions of source soil particles are well characterized, then chemical compositions of Asian Dust particles collected outside source regions can be compared with those of source soil particles in order to find out the occurrence of chemical modification. Asian Dust particles are chemically and morphologically heterogeneous, and thus the average composition and the average aerodynamic diameter (obtainable by bulk analysis) are not much relevant if the chemical modifications of the particles must be followed. The major elemental composition and abundance of the particle types that are potential subjects of chemical modification can only be obtained using single-particle analysis. A single particle analytical technique, named low-Z particle electron probe X-ray microanalysis (low-Z particle EPMA), was applied to characterize two certified reference materials (CRMs) for Asian Dust particles, which were collected from a loess plateau area and a desert of China. The CRMs were defined by bulk analyses to provide certified concentrations for 13 chemical elements. Using the low-Z particle EPMA technique, the concentrations of major chemical species such as aluminosilicates, SiO 2 , CaCO 3 , and carbonaceous species were obtained. Elemental concentrations obtained by the low-Z particle EPMA are close to the certified values, with considering that the single particle and bulk analyses employ very different approaches. There are still some discrepancies between those concentration values, resulting from analyses of particles with different sizes, different sample amounts analyzed, and uncertainties involved in the single particle analysis

  20. EARS: Electronic Access to Reference Service.

    Science.gov (United States)

    Weise, F O; Borgendale, M

    1986-10-01

    Electronic Access to Reference Service (EARS) is a front end to the Health Sciences Library's electronic mail system, with links to the online public catalog. EARS, which became operational in September 1984, is accessed by users at remote sites with either a terminal or microcomputer. It is menu-driven, allowing users to request: a computerized literature search, reference information, a photocopy of a journal article, or a book. This paper traces the history of EARS and discusses its use, its impact on library staff and services, and factors that influence the diffusion of new technology.

  1. Characterization of nanoparticles as candidate reference materials

    International Nuclear Information System (INIS)

    Martins Ferreira, E.H.; Robertis, E. de; Landi, S.M.; Gouvea, C.P.; Archanjo, B.S.; Almeida, C.A.; Araujo, J.R. de; Kuznetsov, O.; Achete, C.A.

    2013-01-01

    We report the characterization of three different nanoparticles (silica, silver and multi-walled carbon nanotubes) as candidate reference material. We focus our analysis on the size distribution of those particles as measured by different microscopy techniques. (author)

  2. NBS activities in biological reference materials

    Energy Technology Data Exchange (ETDEWEB)

    Rasberry, S.D.

    1988-12-01

    NBS activities in biological reference materials during 1986-1988 are described with a preview of plans for future certifications of reference materials. During the period, work has been completed or partially completed on about 40 reference materials of importance to health, nutrition, and environmental quality. Some of the reference materials that have been completed during the period and are described include: creatinine (SRM 914a), bovine serum albumin (SRM 927a), cholesterol in human serum (SRM's 1951-1952), aspartate aminotransferase (RM 8430), cholesterol and fat-soluble vitamins in coconut oil (SRM 1563), wheat flour (SRM 1567a), rice flour (SRM 1568a), mixed diet (RM 8431a), dinitropyrene isomers and 1-nitropyrene (SRM 1596), and complex PAH's from coal tar (SRM 1597). Oyster tissue (SRM 1566a) is being analyzed and should be available in 1988.

  3. Reference materials for microanalytical nuclear techniques

    Energy Technology Data Exchange (ETDEWEB)

    Injuk, Jasna; Grieken, Rene van [Department of Chemistry, Micro and Trace Analysis Centre, University of Antwerp, Wilrijk-Antwerp (Belgium)

    1994-07-01

    This paper discusses some issues concerning reference materials required for microanalysis including physical and chemical properties of the sample matrix and homogeneity of the chemical composition. It gives some examples of the mst common standards used. Further the paper gives background information about the Micro- and Trace Analysis Center of the University of Antwerp, Belgium and discusses recent results of the Center in microanalysis of reference materials.

  4. Reference materials and representative test materials: the nanotechnology case

    International Nuclear Information System (INIS)

    Roebben, G.; Rasmussen, K.; Kestens, V.; Linsinger, T. P. J.; Rauscher, H.; Emons, H.; Stamm, H.

    2013-01-01

    An increasing number of chemical, physical and biological tests are performed on manufactured nanomaterials for scientific and regulatory purposes. Existing test guidelines and measurement methods are not always directly applicable to or relevant for nanomaterials. Therefore, it is necessary to verify the use of the existing methods with nanomaterials, thereby identifying where modifications are needed, and where new methods need to be developed and validated. Efforts for verification, development and validation of methods as well as quality assurance of (routine) test results significantly benefit from the availability of suitable test and reference materials. This paper provides an overview of the existing types of reference materials and introduces a new class of test materials for which the term ‘representative test material’ is proposed. The three generic concepts of certified reference material, reference material(non-certified) and representative test material constitute a comprehensive system of benchmarks that can be used by all measurement and testing communities, regardless of their specific discipline. This paper illustrates this system with examples from the field of nanomaterials, including reference materials and representative test materials developed at the European Commission’s Joint Research Centre, in particular at the Institute for Reference Materials and Measurements (IRMM), and at the Institute for Health and Consumer Protection (IHCP).

  5. A new basaltic glass microanalytical reference material for multiple techniques

    Science.gov (United States)

    Wilson, Steve; Koenig, Alan; Lowers, Heather

    2012-01-01

    The U.S. Geological Survey (USGS) has been producing reference materials since the 1950s. Over 50 materials have been developed to cover bulk rock, sediment, and soils for the geological community. These materials are used globally in geochemistry, environmental, and analytical laboratories that perform bulk chemistry and/or microanalysis for instrument calibration and quality assurance testing. To answer the growing demand for higher spatial resolution and sensitivity, there is a need to create a new generation of microanalytical reference materials suitable for a variety of techniques, such as scanning electron microscopy/X-ray spectrometry (SEM/EDS), electron probe microanalysis (EPMA), laser ablation inductively coupled mass spectrometry (LA-ICP-MS), and secondary ion mass spectrometry (SIMS). As such, the microanalytical reference material (MRM) needs to be stable under the beam, be homogeneous at scales of better than 10–25 micrometers for the major to ultra-trace element level, and contain all of the analytes (elements or isotopes) of interest. Previous development of basaltic glasses intended for LA-ICP-MS has resulted in a synthetic basaltic matrix series of glasses (USGS GS-series) and a natural basalt series of glasses (BCR-1G, BHVO-2G, and NKT-1G). These materials have been useful for the LA-ICP-MS community but were not originally intended for use by the electron or ion beam community. A material developed from start to finish with intended use in multiple microanalytical instruments would be useful for inter-laboratory and inter-instrument platform comparisons. This article summarizes the experiments undertaken to produce a basalt glass reference material suitable for distribution as a multiple-technique round robin material. The goal of the analytical work presented here is to demonstrate that the elemental homogeneity of the new glass is acceptable for its use as a reference material. Because the round robin exercise is still underway, only

  6. Xyce parallel electronic simulator : reference guide.

    Energy Technology Data Exchange (ETDEWEB)

    Mei, Ting; Rankin, Eric Lamont; Thornquist, Heidi K.; Santarelli, Keith R.; Fixel, Deborah A.; Coffey, Todd Stirling; Russo, Thomas V.; Schiek, Richard Louis; Warrender, Christina E.; Keiter, Eric Richard; Pawlowski, Roger Patrick

    2011-05-01

    This document is a reference guide to the Xyce Parallel Electronic Simulator, and is a companion document to the Xyce Users Guide. The focus of this document is (to the extent possible) exhaustively list device parameters, solver options, parser options, and other usage details of Xyce. This document is not intended to be a tutorial. Users who are new to circuit simulation are better served by the Xyce Users Guide. The Xyce Parallel Electronic Simulator has been written to support, in a rigorous manner, the simulation needs of the Sandia National Laboratories electrical designers. It is targeted specifically to run on large-scale parallel computing platforms but also runs well on a variety of architectures including single processor workstations. It also aims to support a variety of devices and models specific to Sandia needs. This document is intended to complement the Xyce Users Guide. It contains comprehensive, detailed information about a number of topics pertinent to the usage of Xyce. Included in this document is a netlist reference for the input-file commands and elements supported within Xyce; a command line reference, which describes the available command line arguments for Xyce; and quick-references for users of other circuit codes, such as Orcad's PSpice and Sandia's ChileSPICE.

  7. Certified reference materials for organic analysis

    International Nuclear Information System (INIS)

    QianChuanfan

    2002-01-01

    This presentation discusses the requirements for certified reference materials (CRMs) to be used in measurements of residues of pesticides in food and environmental samples. It deals with the types of CRMs, matrix selection, sample preparation and representativeness. It also discusses CRM validity period and gives some examples of CRM preparation

  8. Production and certification of reference materials

    International Nuclear Information System (INIS)

    Sarkis, Jorge Eduardo de S.; Kakazu, Mauricio H.; Hespanhol, Emilio Carlos B.; Martins, Elaine Arantes J.

    1996-01-01

    The reference materials used in analytical chemistry permit us to evaluate correctly the analytical producers as well as experimental set up. U 3 O 8 was produced at IPEN to be used as a secondary standard. We present the first results on U 3 O 8 and discuss the method, preparation, and characterization of that oxide. (author)

  9. Immune reactivity of candidate reference materials

    NARCIS (Netherlands)

    Fernandez-Rivas, Montserrat; Aalbers, Marja; Fötisch, Kay; de Heer, Pleuni; Notten, Silla; Vieths, Stefan; van Ree, Ronald

    2006-01-01

    Immune reactivity is a key issue in the evaluation of the quality of recombinant allergens as potential reference materials. Within the frame of the CREATE project, the immune reactivity of the natural and recombinant versions of the major allergens of birch pollen (Bet v 1), grass pollen (Phl p 1

  10. AQCS 1989 - Intercomparison runs reference materials

    International Nuclear Information System (INIS)

    1989-01-01

    The purpose of the Analytical Quality Control Services (AQCS) programme provided by the International Atomic Energy Agency (Agency) is to assist laboratories engaged in the analysis of nuclear, environmental, biological, and materials of marine origin for radionuclide, major, minor and trace elements, as well as stable isotopes using atomic and nuclear analytical techniques, to check the quality of their work. Reference Materials available are listed by origin and by analyte giving referenced values and confidence intervals. Only materials, which have one or more properties sufficiently well established from statistical evaluation of previous interlaboratory comparison studies are included. Existing Reference Materials may be updated for previously referenced constituents or properties according to the results of the Agency's Co-ordinated Research Programmes (CRPs) in these fields or according to recently published literature values. They are supplied with a reference sheet stating relevant parameters and properties of the material and can be used as secondary standards for quality control assurance within a laboratory, for checking analytical methods and/or instrumentation or for training purposes. 4 tabs

  11. AQCS 1990. Intercomparison runs, reference materials

    International Nuclear Information System (INIS)

    1990-01-01

    The purpose of the Analytical Quality Control Services (AQCS) programme provided by the International Atomic Energy Agency (Agency) is to assist laboratories engaged in the analysis of nuclear, environmental, biological, and materials of marine origin for radionuclide, major, minor and trace elements, as well as stable isotopes using atomic and nuclear analytical techniques, to check the quality of their work. Such a control is necessary since results of analytical activities may be the basis upon which economic, administrative, medical or legal decisions are taken; they must, therefore, be documented to be sufficiently reliable. The Agency has instituted the AQCS-programme which for 1990 will involve distributing samples for Intercomparison Runs and Reference Materials in a way similar to that of previous years. The Agency's Analytical Quality Control Services (AQCS) programme provides mainly three types of materials: materials which can be used in analytical laboratories working in the fields of nuclear technology and isotope hydrology. These include uranium ore Reference Materials and other substances of interest for nuclear fuel technology as well as stable isotope Reference Materials for mass spectrometric determination of isotope ratios in natural waters; materials with known content of uranium, thorium and/or transuranium elements or fission products for the determination of environmental radioactivity or control of nuclear safety; materials for use in the determination of stable trace elements in environmental, biomedical and marine research. Radiochemical methods such as neutron activation or isotope dilution analysis are often used in the determination of such trace elements and constitute an important contribution of nuclear techniques to applied science. Tabs

  12. Atomic Reference Data for Electronic Structure Calculations

    CERN Document Server

    Kotochigova, S; Shirley, E L

    We have generated data for atomic electronic structure calculations, to provide a standard reference for results of specified accuracy under commonly used approximations. Results are presented here for total energies and orbital energy eigenvalues for all atoms from H to U, at microHartree accuracy in the total energy, as computed in the local-density approximation (LDA) the local-spin-density approximation (LSD); the relativistic local-density approximation (RLDA); and scalar-relativistic local-density approximation (ScRLDA).

  13. 15 CFR 230.3 - New Standard Reference Materials.

    Science.gov (United States)

    2010-01-01

    ... NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY, DEPARTMENT OF COMMERCE STANDARD REFERENCE MATERIALS STANDARD REFERENCE MATERIALS General Information § 230.3 New Standard Reference Materials. When new SRM's... scientific and trade journals. ...

  14. Biological and environmental reference materials in CENAM.

    Science.gov (United States)

    Arvizu-Torres, R; Perez-Castorena, A; Salas-Tellez, J A; Mitani-Nakanishi, Y

    2001-06-01

    Since 1994, when the NIST/NOAA Quality Assurance Program in Chemical Measurements was discussed in Queretaro, CENAM, the National Measurement Institute (NMI) of Mexico, has become involved in the development of reference materials. In the field of biological and environmental reference materials, in particular, the NORAMET collaboration program with NIST and NRC, and the North-American Environmental Cooperation signed among three free-trade treaty organizations, have greatly helped the development of the materials metrology program in the newly established CENAM. This paper describes some particularly significant efforts of CENAM in the development of biological and environmental reference materials, on the basis of inter-comparison studies organized with local and governmental environmental agencies of Mexico. In the field of water pollution CENAM has developed a practical proficiency testing (PT) scheme for field laboratories, as a part of registration by local government in the metropolitan area, according to the Mexican Ecological Regulation. The results from these eight PTs in the last 5 years have demonstrated that this scheme has helped ensure the reliability of analytical capability of more than 50 field laboratories in three states, Mexico, D.F., and the States of Mexico and Queretaro. Similar experience has been obtained for more than 70 service units of stack emission measurements in the three states in 1998 and 1999, as a result of the design of a PT scheme for reference gas mixtures. This PT scheme has been accomplished successfully by 30 analytical laboratories who provide monitoring services and perform research on toxic substances (Hg, methylmercury, PCB, etc.) in Mexico. To support these activities, reference samples have been produced through the NIST SRMs, and efforts have been made to increase CENAM's capability in the preparation of primary reference materials in spectrometric solutions and gas mixtures. Collaboration among NMIs has also

  15. Development studies of captopril certified reference material

    Directory of Open Access Journals (Sweden)

    Raquel Nogueira

    2011-06-01

    Full Text Available This paper describes the studies performed with the candidate Certified Reference Material (CRM of captopril, the first CRM of an active pharmaceutical ingredient (API in Brazil, including determination of impurities (organic, inorganic and volatiles, homogeneity testing, short- and long-term stability studies, calculation of captopril content using the mass balance approach, and estimation of the associated measurement uncertainty.Este artigo descreve os estudos realizados com o candidato a Material de Referência Certificado (MRC de captopril, primeiro MRC de fármacos no Brasil, incluindo a determinação de impurezas (orgânicas, inorgânicas e voláteis, testes de homogeneidade, testes de estabilidade de curta e longa duração, cálculo do teor de captopril por balanço de massa e estimativa da incerteza de medição associada ao valor certificado.

  16. AQCS intercomparison runs, reference materials 1991

    International Nuclear Information System (INIS)

    1991-01-01

    The purpose of the Analytical Quality Control Services programme provided by the IAEA is to assist laboratories engaged in the analysis of nuclear, environmental, biological, and materials of marine origin for radionuclide, major, minor and trace elements, as well as stable isotopes using atomic and nuclear analytical techniques, to check the quality of their work. The determination of accuracy requires special procedures such as analysis to be carried out by as many different and independent methods, analysts and techniques as possible, control analysis with reference materials and participation in interlaboratory comparison studies. This document gives details of the specimens and samples which the IAEA intends to distribute in 1991. Tabs

  17. Reference material systems: a sourcebook for material assessment

    Energy Technology Data Exchange (ETDEWEB)

    Bhagat, N. (ed.)

    1976-12-01

    A reference set of data related to material systems and a framework for carrying out the material technologies assessment are presented. While the bulk of renewables have been considered in this report, the nonrenewable materials dealt with here include structural materials only, such as steel, aluminum, cement and concrete, and bricks. The complete data set is supposed to include material flows, energy requirements, capital and labor inputs, and environmental effects for each process that a resource must go through to become a useful material for an end use. Although effort has been made to obtain as much information as possible, considerable gaps in data, apparent throughout this report, could not be avoided. A new material technology can be evaluated by substituting that technology for appropriate elements of the reference materials system and calculating the net change in material resource, energy, capital and labor requirements, and environmental impacts. This combination of information thus serves as a means of evaluating the potential benefits to be gained by research in various material technologies.

  18. Development and use of reference materials and quality control materials

    International Nuclear Information System (INIS)

    2003-04-01

    Current knowledge is summarized on correct use of commercially available certified reference materials (CRMs) and reference materials (RMs). Acknowledged are also the limitations and restrictions analysts have to face if they want to apply quality control. The concept of in-house RMs or quality control materials (QCMs) is advocated to supplement the use of CRMs for quality control purposes. On hand advice on how to select, prepare, characterize and use these QCMs is given from the experts' perspective. Several scenarios are described to make this concept widely applicable to: advanced laboratories with CRMs with validated analytical techniques available, laboratories with less experience and facilities, as well as cases were labile compounds and unstable matrices are involved. Each scenario considers different approaches to overcome the lack of appropriate CRMs and advise on the preparation of QCMs, which might fit the particular purpose

  19. Development and use of reference materials and quality control materials

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2003-04-01

    Current knowledge is summarized on correct use of commercially available certified reference materials (CRMs) and reference materials (RMs). Acknowledged are also the limitations and restrictions analysts have to face if they want to apply quality control. The concept of in-house RMs or quality control materials (QCMs) is advocated to supplement the use of CRMs for quality control purposes. On hand advice on how to select, prepare, characterize and use these QCMs is given from the experts' perspective. Several scenarios are described to make this concept widely applicable to: advanced laboratories with CRMs with validated analytical techniques available, laboratories with less experience and facilities, as well as cases were labile compounds and unstable matrices are involved. Each scenario considers different approaches to overcome the lack of appropriate CRMs and advise on the preparation of QCMs, which might fit the particular purpose.

  20. Analytical quality control service programme, intercomparison runs, certified reference materials, reference materials 1987-88

    International Nuclear Information System (INIS)

    1986-12-01

    The purpose of the Analytical Quality Control Services (AQCS) programme provided by the IAEA, is to assist laboratories engaged in the analysis of nuclear, environmental, biological, and materials of marine origin for radionuclide, major, minor and trace elements, as well as stable isotopes using atomic and nuclear analytical techniques, to check the quality of their work. The tables give details of the intercomparison samples and reference materials distributed by the IAEA in the period 1987 to 1988. 2 tabs

  1. Value assignment of nutrient concentrations in five standard reference materials and six reference materials.

    Science.gov (United States)

    Sharpless, K E; Gill, L M

    2000-01-01

    A number of food-matrix reference materials (RMs) are available from the National Institute of Standards and Technology (NIST) and from Agriculture Canada through NIST. Most of these materials were originally value-assigned for their elemental composition (major, minor, and trace elements), but no additional nutritional information was provided. Two of the materials were certified for selected organic constituents. Ten of these materials (Standard Reference Material [SRM] 1,563 Cholesterol and Fat-Soluble Vitamins in Coconut Oil [Natural and Fortified], SRM 1,566b Oyster Tissue, SRM 1,570a Spinach Leaves, SRM 1,974a Organics in Mussel Tissue (Mytilus edulis), RM 8,415 Whole Egg Powder, RM 8,418 Wheat Gluten, RM 8,432 Corn Starch, RM 8,433 Corn Bran, RM 8,435 Whole Milk Powder, and RM 8,436 Durum Wheat Flour) were recently distributed by NIST to 4 laboratories with expertise in food analysis for the measurement of proximates (solids, fat, protein, etc.), calories, and total dietary fiber, as appropriate. SRM 1846 Infant Formula was distributed as a quality control sample for the proximates and for analysis for individual fatty acids. Two of the materials (Whole Egg Powder and Whole Milk Powder) were distributed in an earlier interlaboratory comparison exercise in which they were analyzed for several vitamins. Value assignment of analyte concentrations in these 11 SRMs and RMs, based on analyses by the collaborating laboratories, is described in this paper. These materials are intended primarily for validation of analytical methods for the measurement of nutrients in foods of similar composition (based on AOAC INTERNATIONAL's fat-protein-carbohydrate triangle). They may also be used as "primary control materials" in the value assignment of in-house control materials of similar composition. The addition of proximate information for 10 existing reference materials means that RMs are now available from NIST with assigned values for proximates in 6 of the 9 sectors of

  2. Polymer electronic devices and materials.

    Energy Technology Data Exchange (ETDEWEB)

    Schubert, William Kent; Baca, Paul Martin; Dirk, Shawn M.; Anderson, G. Ronald; Wheeler, David Roger

    2006-01-01

    Polymer electronic devices and materials have vast potential for future microsystems and could have many advantages over conventional inorganic semiconductor based systems, including ease of manufacturing, cost, weight, flexibility, and the ability to integrate a wide variety of functions on a single platform. Starting materials and substrates are relatively inexpensive and amenable to mass manufacturing methods. This project attempted to plant the seeds for a new core competency in polymer electronics at Sandia National Laboratories. As part of this effort a wide variety of polymer components and devices, ranging from simple resistors to infrared sensitive devices, were fabricated and characterized. Ink jet printing capabilities were established. In addition to promising results on prototype devices the project highlighted the directions where future investments must be made to establish a viable polymer electronics competency.

  3. Development of solid water-equivalent radioactive certified reference materials

    International Nuclear Information System (INIS)

    Finke, E.; Greupner, H.; Groche, K.; Rittwag, R.; Geske, G.

    1991-01-01

    This paper presents a brief description of the development of solid water-equivalent beta volume radioactive certified reference materials. These certified reference materials were prepared for the beta fission nuclides 90 Sr/ 90 Y, 137 Cs, 147 Pm and 204 Tl. Comparative measurements of liquid and solid water-equivalent beta volume radioactive certified reference materials are discussed. (author)

  4. An outline of reference materials for analysis techniques in China

    Energy Technology Data Exchange (ETDEWEB)

    Yuanxun, Zhang; Yine, Qian; Yongping, Zhang; Yongpeng, Tong [Shanghai Institute of Nuclear Research, Academia Sinica (China)

    1994-07-01

    This paper provides background information on the development in the field of reference materials in China. The major considerations in development of reference materials include homogeneity, stability, handling procedures and certification. Further it discusses the plans for development in the near future specific natural-matrix reference materials containing low levels of trace elements and having high degree of homogeneity.

  5. An outline of reference materials for analysis techniques in China

    International Nuclear Information System (INIS)

    Zhang Yuanxun; Qian Yine; Zhang Yongping; Tong Yongpeng

    1994-01-01

    This paper provides background information on the development in the field of reference materials in China. The major considerations in development of reference materials include homogeneity, stability, handling procedures and certification. Further it discusses the plans for development in the near future specific natural-matrix reference materials containing low levels of trace elements and having high degree of homogeneity

  6. REFERENCE MATERIALS IN THE SPHERE OF USE OF ATOMIC ENERGY

    Directory of Open Access Journals (Sweden)

    V. A. Borisov

    2015-01-01

    Full Text Available The article describes the chronology of development of the system of reference materials in the nuclear industry of the Russian Federation. The basic documents used in the sphere of nuclear energy are described. The nomenclature of reference materials and feature of their application in the "Rosatom" is given. The prospects of development activities in the field of reference materials are formulated.

  7. Certification of an iron metal reference material for neutron dosimetry (EC nuclear reference material 524)

    International Nuclear Information System (INIS)

    Ingelbrecht, C.; Pauwels, J.; Lievens, F.

    1993-01-01

    Iron metal, of > 99.996% nominal purity, in the form of 0.1 mm thick foil and of 0.5 mm diameter wire has been certified for its manganese and cobalt mass fractions. The certified value of the cobalt mass fraction ( -1 ) is based on 39 accepted results from five laboratories using two different methods. The certified value of the manganese mass fraction ( -1 ) is based on 41 accepted results from five laboratories using three different methods. The overall purity was also verified. The material is intended to be used as a reference material in neutron dosimetry. (authors). 8 refs., 9 tabs., 2 figs

  8. Certification of a nickel metal reference material for neutron dosimetry (EC Nuclear Reference Material 521)

    International Nuclear Information System (INIS)

    Pauwels, J.

    1988-01-01

    Nickel metal, of 99.99 % nominal purity and natural isotopic composition, in the form of 0.1 mm thick foil and 0.5 mm diameter wire has been certified for its cobalt mass fraction. The certified value of cobalt (<0.1μg.g-1) is based on 38 results obtained by neutron activation analysis, emission spectrometry with inductively coupled plasma excitation and atomic absorption spectrometry, whereas the isotopic composition of the nickel was verified by thermal ionization mass spectrometry. The material is intended to be used as a reference material in neutron metrology

  9. Certification of a niobium metal reference material for neutron dosimetry (EC nuclear reference material 526)

    International Nuclear Information System (INIS)

    Ingelbrecht, C.; Pauwels, J.

    1990-01-01

    Niobium metal, of 99.999% nominal purity, in the form of 0.02 and 0.1 mm thick foil and of 0.5 mm diameter wire, has been certified for its tantalum mass fraction. The certified value of the tantalum mass fraction is 0.3 ± 0.09 mg. Kg -1 , and is based on 70 results obtained by six independent laboratories by neutron activation analysis or inductively coupled plasma mass spectrometry. The material is intended to be used as a reference material in neutron metrology

  10. Certification of an aluminium metal reference material for neutron dosimetry (EC nuclear reference material 523)

    International Nuclear Information System (INIS)

    Pauwels, J.; Ingelbrecht, C.

    1990-01-01

    Aluminium metal of > 99.999% nominal purity in the form of 0.1 mm and 1 mm thick foil and of 1 mm diameter wire has been certified for its sodium mass fraction. The certified value of the sodium mass fraction ( -1 ) is based on 21 results from three laboratories using two different methods, which are neutron activation analysis and atomic absorption spectrometry. The overall purity was estimated using spark source mass spectrometry and neutron activation analysis. The material is intended to be used as a reference material in neutron metrology

  11. Material control system simulator program reference manual

    Energy Technology Data Exchange (ETDEWEB)

    Hollstien, R.B.

    1978-01-24

    A description is presented of a Material Control System Simulator (MCSS) program for determination of material accounting uncertainty and system response to particular adversary action sequences that constitute plausible material diversion attempts. The program is intended for use in situations where randomness, uncertainty, or interaction of adversary actions and material control system components make it difficult to assess safeguards effectiveness against particular material diversion attempts. Although MCSS may be used independently in the design or analysis of material handling and processing systems, it has been tailored toward the determination of material accountability and the response of material control systems to adversary action sequences.

  12. Material control system simulator program reference manual

    International Nuclear Information System (INIS)

    Hollstien, R.B.

    1978-01-01

    A description is presented of a Material Control System Simulator (MCSS) program for determination of material accounting uncertainty and system response to particular adversary action sequences that constitute plausible material diversion attempts. The program is intended for use in situations where randomness, uncertainty, or interaction of adversary actions and material control system components make it difficult to assess safeguards effectiveness against particular material diversion attempts. Although MCSS may be used independently in the design or analysis of material handling and processing systems, it has been tailored toward the determination of material accountability and the response of material control systems to adversary action sequences

  13. Material synthesis and evaluation of metrological characteristics of potassium fluozirconate certified reference material

    Directory of Open Access Journals (Sweden)

    D. G. Lisienko

    2016-01-01

    Full Text Available The relevance of the study. For metrological support of control methods for composition ofpotassium fluozirconate, used in the production of metallic zirconium, applied in various technical fields, including nuclear power, electronics, chemical engineering. The purpose: development of synthesis technology, and determination of metrological characteristics of certified reference material for composition ofpotassium fluozirconate (set, intended for metrological support of measuring element mass fraction: hafnium (Hf, silicon (Si, iron (Fe, aluminium (Al, chromium (Cr, tin (Sn, titanium (Ti in potassium fluozirconate. Research methods: X-ray diffraction, differential scanning colorimetry, thermogravimetric analysis, atomic-emission spectral analysis with arc excitation, mass spectral analysis, X-ray fluorescence analysis. Results. As a result of research a set of certified reference materials for composition of potassium fluozirconate is developed and produced. The CRM type is approved by Federal Agency on Technical Regulating and Metrology and registered in State Register of Approved Reference Material Types under number GSO 10593-2015.

  14. Certification of a copper metal reference material for neutron dosimetry. (EC nuclear reference material 522)

    International Nuclear Information System (INIS)

    Ingelbrecht, C.; Pauwels, J.; Lievens, F.

    1993-01-01

    Copper metal of ≥ 99.995% nominal purity in the form of 0.1 and 1.0 mm thick foil and 0.5 and 1.0 mm diameter wire has been certified for its cobalt and silver mass fractions. The certified values are -1 and 0.95 ± 0.04 mg.kg -1 respectively, based on 66 results for cobalt and 88 results for silver obtained by nine laboratories using three methods. This reference material, EC-NRM 522, is intended for reactor neutron dosimetry. (authors). 14 refs., 1 annexe, 10 tabs., 2 figs

  15. Certification of a uranium-238 dioxide reference material for neutron dosimetry (EC nuclear reference material 501)

    International Nuclear Information System (INIS)

    Pauwels, J.; Lievens, F.; Ingelbrecht, C.

    1989-01-01

    Uranium-238 oxide of 99.999% isotopic and 99.98% chemical purity was transformed into dioxide spheres of nominal 0.5 and 1.0 mm diameter by gel precipitation and subsequent calcination under carbon dioxide and under argon containing 5% hydrogen at 1 125 K. The spheres were analysed by thermal ionization mass spectrometry, including isotope dilution, by gravimetry and by potentiometric titration. On the basis of these analyses, the uranium mass fraction was certified at 879.4 ± 2.8 g.kg -1 , and the 235 U/U - and 238 U/U abundances at 10.4 ± 0.5 mg.kg -1 and 999.9896 ± 0.0005 g.kg -1 , respectively. The material is intended to be used as a reference material in neutron metrology

  16. New reference materials improvement of methods of measurements

    International Nuclear Information System (INIS)

    Marchandise, H.

    1985-01-01

    The report summarizes the development of about 120 reference materials in a variety of fields (non ferrous metals, trace element analysis, food products, biomedical analysis, physical and technical properties of solid materials). The document also provides practical advice for trace element analyses, describes the principles followed for certifying reference materials and provides recommendations for their use

  17. Reference nano-dimensional metrology by scanning transmission electron microscopy

    International Nuclear Information System (INIS)

    Dai, Gaoliang; Fluegge, Jens; Bosse, Harald; Heidelmann, Markus; Kübel, Christian; Prang, Robby

    2013-01-01

    Traceable and accurate reference dimensional metrology of nano-structures by scanning transmission electron microscopy (STEM) is introduced in the paper. Two methods, one based on the crystal lattice constant and the other based on the pitch of a feature pair, were applied to calibrate the TEM magnification. The threshold value, which was defined as the half-intensity of boundary materials, is suggested to extract the boundary position of features from the TEM image. Experimental investigations have demonstrated the high potential of the proposed methods. For instance, the standard deviation from ten repeated measurements of a line structure with a nominal 100 nm critical dimension (CD) reaches 1σ = 0.023 nm, about 0.02%. By intentionally introduced defocus and larger sample alignment errors, the investigation shows that these influences may reach 0.20 and 1.3 nm, respectively, indicating the importance of high-quality TEM measurements. Finally, a strategy for disseminating the destructive TEM results is introduced. Using this strategy, the CD of a reference material has been accurately determined. Its agreement over five independent TEM measurements is below 1.2 nm. (paper)

  18. Development of solid water-equivalent radioactive certified reference materials

    Energy Technology Data Exchange (ETDEWEB)

    Finke, E.; Greupner, H.; Groche, K.; Rittwag, R. (Office for Standardization, Metrology and Quality Control (ASMW), Berlin (Germany, F.R.)); Geske, G. (Jena Univ. (Germany, F.R.))

    1991-01-01

    This paper presents a brief description of the development of solid water-equivalent beta volume radioactive certified reference materials. These certified reference materials were prepared for the beta fission nuclides {sup 90}Sr/{sup 90}Y, {sup 137}Cs, {sup 147}Pm and {sup 204}Tl. Comparative measurements of liquid and solid water-equivalent beta volume radioactive certified reference materials are discussed. (author).

  19. Biological reference materials and analysis of toxic elements

    Energy Technology Data Exchange (ETDEWEB)

    Subramanian, R; Sukumar, A

    1988-12-01

    Biological monitoring of toxic metal pollution in the environment requires quality control analysis with use of standard reference materials. A variety of biological tissues are increasingly used for analysis of element bioaccumulation, but the available Certified Reference Materials (CRMs) are insufficient. An attempt is made to review the studies made using biological reference materials for animal and human tissues. The need to have inter-laboratory studies and CRM in the field of biological monitoring of toxic metals is also discussed.

  20. Determination of carbon-14 in environmental level, solid reference materials

    Energy Technology Data Exchange (ETDEWEB)

    Blowers, Paul, E-mail: paul.blowers@cefas.co.uk [Cefas Lowestoft Laboratory, Pakefield Road, Lowestoft, Suffolk, NR33 0HT (United Kingdom); Caborn, Jane, E-mail: jane.a.caborn@nnl.co.uk [NNL, Springfields, Salwick, Preston, Lancashire, PR4 0XJ (United Kingdom); Dell, Tony [Veterinary Laboratories Agency, New Haw, Addlestone, Surrey, KT15 3NB (United Kingdom); Gingell, Terry [DSTL, Radiation Protection Services, Crescent Road, Alverstoke, Gosport, Hants, PO12 2DL (United Kingdom); Harms, Arvic [National Physical Laboratory, Hampton Road, Teddington, Middlesex, TW11 0LW (United Kingdom); Long, Stephanie [Radiological Protection Institute of Ireland, 3 Clonskeagh Square, Clonskeagh Road, Dublin 14, Ireland (United Kingdom); Sleep, Darren [Centre for Ecology and Hydrology, Lancaster Environment Centre, Library Avenue, Bailrigg, Lancaster, LA1 4AP (United Kingdom); Stewart, Charlie [UKAEA (Waste Management Group), Chemical Support Services, D1310/14, Dounreay, Thurso, Caithness, KW14 7TZ (United Kingdom); Walker, Jill [Radiocarbon Dating, The Old Stables, East Lockinge, Wantage, Oxon OX12 8QY (United Kingdom); Warwick, Phil E. [GAU-Radioanalytical, National Oceanography Centre Southampton, European Way, Southampton, SO14 3ZH (United Kingdom)

    2011-10-15

    An intercomparison exercise to determine the {sup 14}C activity concentrations in a range of solid, environmental level materials was conducted between laboratories in the UK. IAEA reference materials, C2, C6 and C7, and an in-house laboratory QA material were dispatched in 2006 to ten laboratories comprising of members of the Analyst Informal Working Group (AIWG) and one other invited party. The laboratories performed the determinations using a number of techniques, and using the results each one was evaluated in terms of levels of precision, sensitivity and limits of detection. The results of the study show that all techniques are capable of successfully analysing {sup 14}C in environmental level materials, however, a shortage of certified environmental reference materials exists. The suitability of the IAEA reference materials and other material for use as reference materials was also assessed.

  1. Determination of carbon-14 in environmental level, solid reference materials

    International Nuclear Information System (INIS)

    Blowers, Paul; Caborn, Jane; Dell, Tony; Gingell, Terry; Harms, Arvic; Long, Stephanie; Sleep, Darren; Stewart, Charlie; Walker, Jill; Warwick, Phil E.

    2011-01-01

    An intercomparison exercise to determine the 14 C activity concentrations in a range of solid, environmental level materials was conducted between laboratories in the UK. IAEA reference materials, C2, C6 and C7, and an in-house laboratory QA material were dispatched in 2006 to ten laboratories comprising of members of the Analyst Informal Working Group (AIWG) and one other invited party. The laboratories performed the determinations using a number of techniques, and using the results each one was evaluated in terms of levels of precision, sensitivity and limits of detection. The results of the study show that all techniques are capable of successfully analysing 14 C in environmental level materials, however, a shortage of certified environmental reference materials exists. The suitability of the IAEA reference materials and other material for use as reference materials was also assessed.

  2. 40 CFR 86.1 - Reference materials.

    Science.gov (United States)

    2010-07-01

    ... Chromatography, 1994 SAE Handbook—SAE International Cooperative Engineering Program, Volume 1: Materials, Fuels... Method for Analysis of Natural Gas by Gas Chromatography, IBR approved for §§ 86.113-94, 86.513-94, 86...) Gases and Propane Concentrates by Gas Chromatography, IBR approved for §§ 86.113-94, 86.1213-94, 86.1313...

  3. Evaluating Electronic Reference Services: Issues, Approaches and Criteria.

    Science.gov (United States)

    Novotny, Eric

    2001-01-01

    Discussion of electronic library reference services focuses on an overview of the chief methodologies available for conducting assessments of electronic services. Highlights include quantitative measures and benchmarks, including equity and access; quality measures; behavioral aspects of quality, including librarian-patron interaction; and future…

  4. Use of gamma spectrometry for analysis of three reference materials

    International Nuclear Information System (INIS)

    Kinova, L.

    2004-01-01

    All reference materials (Reference material A: weight = 49.23 g; Reference material B: weight = 36.08 g; Reference material C: weight = 26.18 g) were packed in 50 cm 3 polypropylene vials, sealed and measured consecutively three times at intervals of the average of 25 days. Low background gamma spectrometry system: HPGe detector with high energy resolution (FWHM for 1332 KeV of Co-60 is 1.9 KeV, Relative counting efficiency for the same energy is 21 %) was used. Results: All materials are of low activity and must be measured for a long time.The highest specific activity of a man-made radionuclides Cs-137 and Am-241 is in the material A. An instrumentally measurable activity of Pb-210 also can be observed in this material. Medium values are in the material B. The reference material C according to the specific activity seems to be a low natural radioactivity material with highest activity of natural nuclides Th-232 and Pa-234 (progeny of U-238). Conclusions: Gamma spectrometry is an useful tool for initial measurement of materials with low radioactivity. Such measurements give an orientation for the nuclides content and approximate activity in the material for the following radiochemical determinations

  5. Development of natural matrix reference materials for monitoring environmental radioactivity

    International Nuclear Information System (INIS)

    Holmes, A.S.; Houlgate, P.R.; Pang, S.; Brookman, B.

    1992-01-01

    The Department of the Environment commissioned the Laboratory of the Government Chemist to carry out a contract on natural matrix reference materials. A survey of current availability of such materials in the western world, along with the UK's need, was conducted. Four suitable matrices were identified for production and validation. Due to a number of unforeseen problems with the collection, processing and validation of the materials, the production of the four identified reference materials was not completed in the allocated period of time. In the future production of natural matrix reference materials the time required, the cost and the problems encountered should not be underestimated. Certified natural matrix reference materials are a vital part of traceability in analytical science and without them there is no absolute method of checking the validity of measurement in the field of radiochemical analysis. (author)

  6. A new certified reference material for size analysis of nanoparticles

    International Nuclear Information System (INIS)

    Braun, Adelina; Kestens, Vikram; Franks, Katrin; Roebben, Gert; Lamberty, Andrée; Linsinger, Thomas P. J.

    2012-01-01

    A certified reference material, ERM-FD100, for quality assurance and validation of various nanoparticle sizing methods, was developed by the Institute for Reference Materials and Measurements. The material was prepared from an industrially sourced colloidal silica containing nanoparticles with a nominal equivalent spherical diameter of 20 nm. The homogeneity and stability of the candidate reference material was assessed by means of dynamic light scattering and centrifugal liquid sedimentation. Certification of the candidate reference material was based on a global interlaboratory comparison in which 34 laboratories participated with various analytical methods (DLS, CLS, EM, SAXS, ELS). After scrutinising the interlaboratory comparison data, 4 different certified particle size values, specific for the corresponding analytical method, could be assigned. The good comparability of results allowed the certification of the colloidal silica material for nanoparticle size analysis.

  7. Preparation of reference material for the measurement of natural radioactivity

    International Nuclear Information System (INIS)

    Ben Tekaya, Malik

    2010-01-01

    The objective of this work is to prepare reference material for the calibration of gamma spectrometry, alpha and XRF .Many procedures of chemical preparation and radiological analysis of a reference material from Triple Superphosphate were tested. Several techniques and methods of measurement were used. In addition to a description and validation of these procedures, a study of repeatability was conducted which resulted in a positive characterization of this material.

  8. Preparation of plant-specific NDA reference material

    International Nuclear Information System (INIS)

    Abedin-Zadeh, R.; Beetle, T.; Kuhn, E.; Terrey, D.; Turel, S.; Busca, G.; Guardini, S.

    1983-01-01

    The importance of having suitable and well characterized non-destructive assay (NDA) reference materials for the verification activities of the safeguards control authorities is stressed. The Euratom Inspectorate and the IAEA have initiated an extensive programme for the procurement and preparation of Joint Euratom/IAEA safeguards NDA reference materials with the active participation of the Ispra Establishment of the Euratom Joint Research Centre. The different type and nature of materials, condition of measurements, and plant characteristics and provisions had to be taken into account for plant-specific NDA reference materials. The preparation of each reference material was planned case by case and specific criteria such as limitations in different facilities, measurement capabilities, conditions, product availability and population variability are being ascertained. A procurement scheme was prepared describing step-by-step procedures detailing responsibilities, measurement conditions, destructive analysis schemes, desired characteristics and methods of data evaluation. This paper describes the principles and procedures carried out for the preparation of a reference MOX pin, low enriched uranium reference rods, low enriched uranium reference drums, reference MTR assemblies, and THTR reference pebbles. The scheme for each characterization technique is presented. (author)

  9. The importance of reference materials in doping-control analysis.

    Science.gov (United States)

    Mackay, Lindsey G; Kazlauskas, Rymantas

    2011-08-01

    Currently a large range of pure substance reference materials are available for calibration of doping-control methods. These materials enable traceability to the International System of Units (SI) for the results generated by World Anti-Doping Agency (WADA)-accredited laboratories. Only a small number of prohibited substances have threshold limits for which quantification is highly important. For these analytes only the highest quality reference materials that are available should be used. Many prohibited substances have no threshold limits and reference materials provide essential identity confirmation. For these reference materials the correct identity is critical and the methods used to assess identity in these cases should be critically evaluated. There is still a lack of certified matrix reference materials to support many aspects of doping analysis. However, in key areas a range of urine matrix materials have been produced for substances with threshold limits, for example 19-norandrosterone and testosterone/epitestosterone (T/E) ratio. These matrix-certified reference materials (CRMs) are an excellent independent means of checking method recovery and bias and will typically be used in method validation and then regularly as quality-control checks. They can be particularly important in the analysis of samples close to threshold limits, in which measurement accuracy becomes critical. Some reference materials for isotope ratio mass spectrometry (IRMS) analysis are available and a matrix material certified for steroid delta values is currently under production. In other new areas, for example the Athlete Biological Passport, peptide hormone testing, designer steroids, and gene doping, reference material needs still need to be thoroughly assessed and prioritised.

  10. Determination of ancient ceramics reference material by neutron activation analysis

    International Nuclear Information System (INIS)

    Li Huhou; Sun Jingxin; Wang Yuqi; Lu Liangcai

    1986-01-01

    Contents of trace elements in the reference material of ancient ceramics (KPS-1) were determined by means of activation analysis, using thermal neutron irradiation produced in nuclear reactor. KPS-1 favoured the analysis of ancient ceramics because it had not only many kinds of element but also appropriate contents of composition. The values presented here are reliable within the experimental precision, and have shown that the reference material had a good homogeneity. So KPS-1 can be used as a suitable reference material for the ancient ceramics analysis

  11. Certified reference materials of trace elements in water

    Indian Academy of Sciences (India)

    Many decisions regarding the suitability of material/products are based on the ... In the present scenario of globalization of economy, use of certified reference ... our national accreditation body, National Accreditation Board for Testing and ...

  12. A 244Pu spike reference material CBNM IRM-042A

    International Nuclear Information System (INIS)

    Verbruggen, A.; Gallet, M.; Hendrickx, F.; Bievre, P. de

    1991-01-01

    An highly enriched 244 Pu isotopic reference material (CBNM IRM-042a) has been prepared and certified for 244 Pu isotope concentration. The certified value of (2.257 7 ± 0.004 4).10 18 atoms 242 Pu.kg -1 of solution has been established by isotope dilution mass spectrometry. The plutonium isotopic composition has been determined by thermal ionization mass spectrometry and calibration of these measurements by means of synthetic 242 Pu/ 239 Pu mixtures. The isotopic reference material is supplied in a sealed glass ampoule containing approximately 10 g of a 5M nitric acid solution at an approximate concentration of 1 μg Pu per g solution. This isotopic reference material is part of a systematic CBNM programme to supply spike isotopic reference materials of various isotopes at different concentrations

  13. The development and evaluation of reference materials for food microbiology

    NARCIS (Netherlands)

    Veld, in 't P.

    1998-01-01

    Since 1986 the National Institute of Public Health and the Environment (RIVM) has worked on the development and evaluation of microbiological reference materials (RMs) with support from the European Communities Bureau of Reference (BCR), now called Standards Measurement and Testing

  14. Preparation and certification of reference materials for the nuclear industry

    International Nuclear Information System (INIS)

    Wagner, J.F.

    1994-01-01

    CETAMA (Commission for the Establishment of Analytical Methods) of the Cea group is producing and certifying uranium and plutonium reference materials to meet the requirements of analytical laboratories in the nuclear industry. Reference materials are required at all stages in the fuel cycle: from extraction of uranium, purification, conversion, uranium enrichment, fuel fabrication until reprocessing of spent fuel, management and storage of waste. 3 tabs

  15. Preparation and characterization of the fish reference material

    International Nuclear Information System (INIS)

    Ulrich, Joao Cristiano

    2011-01-01

    The certified reference materials (CRMs) play an important role in obtaining measurement results traceable to the International System of Units, through an unbroken chain of comparisons. Thus, the demand for new certified reference materials (CRMs) increases every day in all areas of knowledge. The availability of reference materials, mainly in Brazil is still incipient, given that the demand far exceeds the available variety of these materials. The amount of certified reference materials available in the country is insufficient to meet the need of the scientific community and demands for development of new methodologies. Among the many areas in need of reference materials, we highlight the importance for the food trade balance for these products within the country. The certification of food products, intended both for export and for domestic consumption, requires analysis methods that provide precise and accurate results to ensure product quality. This paper describes the preparation and certification of a reference material in the fish matrix in mercury and methylmercury. The study brings together since the stage of material selection, preparation, development of homogeneity and stability studies and characterization. The certification was performed by means of measurements using two analytical techniques, flow injection analysis - cold vapor atomic absorption spectrometry (FIA-CV-AAS) and isotope dilution applied to mass spectrometry (IDMS), which is a primary method. In this work the standards of the ISO 30 (ABNT 30-34) and ISO Guide 35 was used as the basis for the preparation and characterization of the material. For the calculation of uncertainties was used the GUM and Eurachem guide. As a result, was produced and certified a lot of material in relation to the concentration of mercury (Hg = 0.271 ± 0.057 mg g -1 ) and methylmercury (MeHg = 0.245 ± 0.038 mg g -1 ), and informational values of lead and arsenic. (author)

  16. Advanced Materials and Devices for Bioresorbable Electronics.

    Science.gov (United States)

    Kang, Seung-Kyun; Koo, Jahyun; Lee, Yoon Kyeung; Rogers, John A

    2018-05-15

    Recent advances in materials chemistry establish the foundations for unusual classes of electronic systems, characterized by their ability to fully or partially dissolve, disintegrate, or otherwise physically or chemically decompose in a controlled fashion after some defined period of stable operation. Such types of "transient" technologies may enable consumer gadgets that minimize waste streams associated with disposal, implantable sensors that disappear harmlessly in the body, and hardware-secure platforms that prevent unwanted recovery of sensitive data. This second area of opportunity, sometimes referred to as bioresorbable electronics, is of particular interest due to its ability to provide diagnostic or therapeutic function in a manner that can enhance or monitor transient biological processes, such as wound healing, while bypassing risks associated with extended device load on the body or with secondary surgical procedures for removal. Early chemistry research established sets of bioresorbable materials for substrates, encapsulation layers, and dielectrics, along with several options in organic and bio-organic semiconductors. The subsequent realization that nanoscale forms of device-grade monocrystalline silicon, such as silicon nanomembranes (m-Si NMs, or Si NMs) undergo hydrolysis in biofluids to yield biocompatible byproducts over biologically relevant time scales advanced the field by providing immediate routes to high performance operation and versatile, sophisticated levels of function. When combined with bioresorbable conductors, dielectrics, substrates, and encapsulation layers, Si NMs provide the basis for a broad, general class of bioresorbable electronics. Other properties of Si, such as its piezoresistivity and photovoltaic properties, allow other types of bioresorbable devices such as solar cells, strain gauges, pH sensors, and photodetectors. The most advanced bioresorbable devices now exist as complete systems with successful demonstrations of

  17. Certified reference materials and reference methods for nuclear safeguards and security.

    Science.gov (United States)

    Jakopič, R; Sturm, M; Kraiem, M; Richter, S; Aregbe, Y

    2013-11-01

    Confidence in comparability and reliability of measurement results in nuclear material and environmental sample analysis are established via certified reference materials (CRMs), reference measurements, and inter-laboratory comparisons (ILCs). Increased needs for quality control tools in proliferation resistance, environmental sample analysis, development of measurement capabilities over the years and progress in modern analytical techniques are the main reasons for the development of new reference materials and reference methods for nuclear safeguards and security. The Institute for Reference Materials and Measurements (IRMM) prepares and certifices large quantities of the so-called "large-sized dried" (LSD) spikes for accurate measurement of the uranium and plutonium content in dissolved nuclear fuel solutions by isotope dilution mass spectrometry (IDMS) and also develops particle reference materials applied for the detection of nuclear signatures in environmental samples. IRMM is currently replacing some of its exhausted stocks of CRMs with new ones whose specifications are up-to-date and tailored for the demands of modern analytical techniques. Some of the existing materials will be re-measured to improve the uncertainties associated with their certified values, and to enable laboratories to reduce their combined measurement uncertainty. Safeguards involve the quantitative verification by independent measurements so that no nuclear material is diverted from its intended peaceful use. Safeguards authorities pay particular attention to plutonium and the uranium isotope (235)U, indicating the so-called 'enrichment', in nuclear material and in environmental samples. In addition to the verification of the major ratios, n((235)U)/n((238)U) and n((240)Pu)/n((239)Pu), the minor ratios of the less abundant uranium and plutonium isotopes contain valuable information about the origin and the 'history' of material used for commercial or possibly clandestine purposes, and

  18. Certification of biological candidates reference materials by neutron activation analysis

    Science.gov (United States)

    Kabanov, Denis V.; Nesterova, Yulia V.; Merkulov, Viktor G.

    2018-03-01

    The paper gives the results of interlaboratory certification of new biological candidate reference materials by neutron activation analysis recommended by the Institute of Nuclear Chemistry and Technology (Warsaw, Poland). The correctness and accuracy of the applied method was statistically estimated for the determination of trace elements in candidate reference materials. The procedure of irradiation in the reactor thermal fuel assembly without formation of fast neutrons was carried out. It excluded formation of interfering isotopes leading to false results. The concentration of more than 20 elements (e.g., Ba, Br, Ca, Co, Ce, Cr, Cs, Eu, Fe, Hf, La, Lu, Rb, Sb, Sc, Ta, Th, Tb, Yb, U, Zn) in candidate references of tobacco leaves and bottom sediment compared to certified reference materials were determined. It was shown that the average error of the applied method did not exceed 10%.

  19. Electronic, magnetic, and optical materials

    CERN Document Server

    Fulay, Pradeep

    2013-01-01

    Technological aspects of ferroelectric, piezoelectric and pyroelectric materials are discussed in detail, in a way that should allow the reader to select an optimal material for a particular application. The basics of magnetostatics are described clearly, as are a wide range of magnetic properties of materials … .-Tony Harker, Department of Physics and Astronomy, University College London

  20. Using XML Technologies to Organize Electronic Reference Resources

    OpenAIRE

    Huser, Vojtech; Del Fiol, Guilherme; Rocha, Roberto A.

    2005-01-01

    Provision of access to reference electronic resources to clinicians is becoming increasingly important. We have created a framework for librarians to manage access to these resources at an enterprise level, rather than at the individual hospital libraries. We describe initial project requirements, implementation details, and some preliminary results.

  1. Ion beam processing of advanced electronic materials

    International Nuclear Information System (INIS)

    Cheung, N.W.; Marwick, A.D.; Roberto, J.B.

    1989-01-01

    This report contains research programs discussed at the materials research society symposia on ion beam processing of advanced electronic materials. Major topics include: shallow implantation and solid-phase epitaxy; damage effects; focused ion beams; MeV implantation; high-dose implantation; implantation in III-V materials and multilayers; and implantation in electronic materials. Individual projects are processed separately for the data bases

  2. Evaluation of a reference material for glycated haemoglobin

    NARCIS (Netherlands)

    Weykamp, CW; Penders, TJ; Muskiet, FAJ; vanderSlik, W

    The use of lyophilized blood as a reference material for glycated haemoglobin was investigated with respect to IFCC criteria for calibrators and control materials. Ninety-two laboratories, using 11 methods, detected no changes in glycated haemoglobin content when the lyophilizate was stored for one

  3. High energy electron irradiation of flowable materials

    International Nuclear Information System (INIS)

    Offermann, B.P.

    1975-01-01

    In order to efficiently irradiate a flowable material with high energy electrons, a hollow body is disposed in a container for the material and the material is caused to flow in the form of a thin layer across a surface of the body from or to the interior of the container while the material flowing across the body surface is irradiated. (U.S.)

  4. Newly developed standard reference materials for organic contaminant analysis

    Energy Technology Data Exchange (ETDEWEB)

    Poster, D.; Kucklick, J.; Schantz, M.; Porter, B.; Wise, S. [National Inst. of Stand. and Technol., Gaithersburg, MD (USA). Center for Anal. Chem.

    2004-09-15

    The National Institute of Standards and Technology (NIST) has issued a number of Standard Reference Materials (SRM) for specified analytes. The SRMs are biota and biological related materials, sediments and particle related SRMs. The certified compounds for analysis are polychlorinated biphenyls (PCB), polycylic aromatic hydrocarbons (PAH) and their nitro-analogues, chlorinated pesticides, methylmercury, organic tin compounds, fatty acids, polybrominated biphenyl ethers (PBDE). The authors report on origin of materials and analytic methods. (uke)

  5. LA-ICP-MS of magnetite: Methods and reference materials

    Science.gov (United States)

    Nadoll, P.; Koenig, A.E.

    2011-01-01

    Magnetite (Fe3O4) is a common accessory mineral in many geologic settings. Its variable geochemistry makes it a powerful petrogenetic indicator. Electron microprobe (EMPA) analyses are commonly used to examine major and minor element contents in magnetite. Laser ablation ICP-MS (LA-ICP-MS) is applicable to trace element analyses of magnetite but has not been widely employed to examine compositional variations. We tested the applicability of the NIST SRM 610, the USGS GSE-1G, and the NIST SRM 2782 reference materials (RMs) as external standards and developed a reliable method for LA-ICP-MS analysis of magnetite. LA-ICP-MS analyses were carried out on well characterized magnetite samples with a 193 nm, Excimer, ArF LA system. Although matrix-matched RMs are sometimes important for calibration and normalization of LA-ICP-MS data, we demonstrate that glass RMs can produce accurate results for LA-ICP-MS analyses of magnetite. Cross-comparison between the NIST SRM 610 and USGS GSE-1G indicates good agreement for magnetite minor and trace element data calibrated with either of these RMs. Many elements show a sufficiently good match between the LA-ICP-MS and the EMPA data; for example, Ti and V show a close to linear relationship with correlation coefficients, R2 of 0.79 and 0.85 respectively. ?? 2011 The Royal Society of Chemistry.

  6. Electron and Positron Stopping Powers of Materials

    Science.gov (United States)

    SRD 7 NIST Electron and Positron Stopping Powers of Materials (PC database for purchase)   The EPSTAR database provides rapid calculations of stopping powers (collisional, radiative, and total), CSDA ranges, radiation yields and density effect corrections for incident electrons or positrons with kinetic energies from 1 keV to 10 GeV, and for any chemically defined target material.

  7. Standard and reference materials for marine science. Third edition. Technical memo

    International Nuclear Information System (INIS)

    Cantillo, A.Y.

    1992-08-01

    The third edition of the catalog of reference materials suited for use in marine science, originally compiled in 1986 for NOAA, IOC, and UNEP. The catalog lists close to 2,000 reference materials from sixteen producers and contains information about their proper use, sources, availability, and analyte concentrations. Indices are included for elements, isotopes, and organic compounds, as are cross references to CAS registry numbers, alternate names, and chemical structures of selected organic compounds. The catalog is being published independently by both NOAA and IOC/UNEP and is available from NOAA/NOS/ORCA in electronic form

  8. Nanostructured electronic and magnetic materials

    Indian Academy of Sciences (India)

    R. Narasimhan (Krishtel eMaging) 1461 1996 Oct 15 13:05:22

    and magnetic materials are provided. Advantages of nanocrystalline magnetic mate- rials in the context of ... 2.2 Phosphors for high definition TV. Better resolution of television screens could be ..... materials and that of preparing nanoparticles. This will remain a challenge for the future if nanomaterials are to be competitive.

  9. Environmental testing techniques for electronics and materials

    CERN Document Server

    Dummer, Geoffrey W A; Fry, D W; Higinbotham, W

    2013-01-01

    Environmental Testing Techniques for Electronics and Materials reviews environmental testing techniques for evaluating the performance of electronic equipment, components, and materials. Environmental test planning, test methods, and instrumentation are described, along with the general environmental conditions under which equipment must operate. This book is comprised of 15 chapters and begins by explaining why environmental testing is necessary and describing the environment in which electronics must operate. The next chapter considers how an environmental test plan is designed; the methods

  10. Particle size studies in the preparation of AQCS reference materials

    International Nuclear Information System (INIS)

    Fajgelj, A.; Zeisler, R.; Benesch, T.; Dekner, R.

    1994-01-01

    Particle size determination is one of the important steps in the characterization of physical properties of each particulate material. However, particle size distribution effects also a chemical composition of the material in terms of homogeneity and representativeness of the sample, as well as allows or not a possible sub-sampling of the material. All this is of great importance in the preparation of reference materials for which the chemical composition and physical properties have to be extremely well characterized. In the present paper we intend to present same efforts which have been done by Analytical Quality Control Services (AQCS) of the International Atomic Energy Agency (IAEA) in the field of particle size determination in the production of reference materials. The Malvern product MasterSizer X, based on laser light scattering is used for this purpose and the technique is also shortly discussed. (author)

  11. ENAA of iodine in standard reference material lyophilized human urine

    International Nuclear Information System (INIS)

    Zhang Yongbao; Wang Ke; Wang Ganfeng

    1997-01-01

    The contents of iodine in two kinds of standard reference materials lyophilized human urine are determined by ENAA. The sensitivity of this method is ten times higher than that of TNAA, and the relative standard deviations of ten measurements are 2.9% and 3.3%, respectively. Two certificated reference samples are used for verification of the analysis. The analytical results are in agreement with the recommended values, and the relative error is less than 3%

  12. Preparation and analysis of a marble reference material

    International Nuclear Information System (INIS)

    Carmo Freitas, M.; Moens, L.; Seabra e Barros, J.

    1988-01-01

    A 7 kg stone of a Carrara marble was reduced to grains smaller than 100 μm, mixed and homogenized in order to prepare a marble reference material. The homogeneity was tested for 16 elements by instrumental neutron activation analysis (INAA). Through a one-way analysis of variance based on several analyses of each of 15 bottles and within the same bottle, it was concluded that the inter-bottle heterogeneity is not greater than the intra-bottle heterogeneity. Results on the concentration of major and trace elements in the marble reference material, obtained by different laboratories and different techniques, are given. The limestone certified reference material KALKSTEIN KH was used to evaluate measurement accuracy, to intercalibrate laboratories, and to provide compatibility of measurement data. (author) 10 refs.; 12 tabs

  13. [The water content reference material of water saturated octanol].

    Science.gov (United States)

    Wang, Haifeng; Ma, Kang; Zhang, Wei; Li, Zhanyuan

    2011-03-01

    The national standards of biofuels specify the technique specification and analytical methods. A water content certified reference material based on the water saturated octanol was developed in order to satisfy the needs of the instrument calibration and the methods validation, assure the accuracy and consistency of results in water content measurements of biofuels. Three analytical methods based on different theories were employed to certify the water content of the reference material, including Karl Fischer coulometric titration, Karl Fischer volumetric titration and quantitative nuclear magnetic resonance. The consistency of coulometric and volumetric titration was achieved through the improvement of methods. The accuracy of the certified result was improved by the introduction of the new method of quantitative nuclear magnetic resonance. Finally, the certified value of reference material is 4.76% with an expanded uncertainty of 0.09%.

  14. Preparation and certification of Sargasso seaweed reference material

    Energy Technology Data Exchange (ETDEWEB)

    Okamoto, Kensaku

    1988-01-01

    Sargasso seaweed reference material was prepared from Sargassum felvellum obtained from an unpolluted area in Japan. The sargasso samples were washed, freeze-dried, pulverized, sieved to pass a 80-mesh screen and finally homogenized. Collaborative studies on the elemental analysis of the sargasso reference material were performed using various analytical techniques. Certified values are provided for Ag, As, Ca, Cd, Co, Cu, Fe, K, Mg, Mn, Na, Pb, Rb, Sr, V and Zn, based on results of determinations by at least three independent analytical techniques. Reference values are reported for Al, Br, Cl, Cr, Cs, Hg, I, P, S, Sb, Sc, Se, Ti and U. The sargasso certified reference material contains high levels of alkali metals, alkaline earth metals, I, Br, As and U, while the concentration of trace elements may be considered to be at the lower end of the range of reported values for marine brown algae. The sargasso sample will be of practical use in marine and environmental sciences as a certified reference material having an elemental composition close to background levels.

  15. Standard reference materials analysis for MINT Radiocarbon Laboratory

    International Nuclear Information System (INIS)

    Noraishah Othman; Kamisah Alias; Nasasni Nasrul

    2004-01-01

    As a follow-up to the setting up of the MINT Radiocarbon Dating facility. an exercise on the IAEA standard reference materials was carried out. Radiocarbon laboratories frequently used these 8 natural samples to verify their systems. The materials were either pretreated or analysed directly to determine the activity of 14 C isotopes of the five samples expressed in % Modern (pMC) terms and to make recommendations on further use of these materials. We present the results of the five materials and discuss the analyses that were undertaken. (Author)

  16. Biological and environmental reference materials in neutron activation analysis work

    International Nuclear Information System (INIS)

    Guinn, V.P.; Gavrilas, M.

    1990-01-01

    The great usefulness of reference materials, especially ones of certified elemental composition, is discussed with particular attention devoted to their use in instrumental neutron activation analysis (INAA) work. Their use, including both certified and uncertified values, in calculations made by the INAA Advance Prediction Computer Program (APCP) is discussed. The main features of the APCP are described, and mention is made of the large number of reference materials run on the APCP (including the new personal computer version of the program), with NBS Oyster Tissue SRM-1566 used as the principal examle. (orig.)

  17. Certification of biological reference materials by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Lanjewar, Mamata R.; Lanjewar, R.B.

    2014-01-01

    A multielemental instrumental neutron activation analysis (INAA) method by short and long irradiation has been employed for the determination of 21 minor and trace elements in two standard Reference Materials P-RBF and P-WBF from Institute of Radioecology and Applied Nuclear Techniques ,Czechoslovakia. Also some biological standards such as Bowen's kale, cabbage leaves (Poland) including wheat and rice flour samples of local origin were analysed. It is suggested that INAA is an ideal method for the certification of Reference Materials of Biological Matrices. (author)

  18. On criteria for examining analysis quality with standard reference material

    International Nuclear Information System (INIS)

    Yang Huating

    1997-01-01

    The advantages and disadvantages and applicability of some criteria for examining analysis quality with standard reference material are discussed. The combination of the uncertainties of the instrument examined and the reference material should be determined on the basis of specific situations. Without the data of the instrument's uncertainty, it would be applicable to substitute the standard deviation multiplied by certain times for the uncertainty. The result of the examining should not result in more error reported in routine measurements than it really is. Over strict examining should also be avoided

  19. Preparation of in-house graphite reference material for boron

    International Nuclear Information System (INIS)

    Kumar, Sanjukta A.; Venkatesh, K.; Swain, Kallola K.; Manisha, V.; Kamble, Granthali S.; Pandey, Shailaja P.; Remya Devi, P.S.; Ghosh, M.; Verma, R.

    2016-05-01

    Graphite is extensively used in nuclear technology. Boron concentration in graphite is one of the important parameters that decide its acceptability for nuclear applications. Reliable analytical methods are essential for the determination of boron in graphite at concentration about 5 mg kg -1 . Reference materials are used for validation of existing analytical methods and developing new methodologies. In view of the importance of determination of boron in graphite and unavailability of graphite reference material, an In-house graphite reference material was prepared in Analytical Chemistry Division. Graphite source material was procured, processed to obtain powder of ≤ 75 μm (200 mesh) and bottled. Procedures were developed for the determination of boron in graphite using inductively coupled plasma optical emission spectrometry (ICPOES) and inductively coupled plasma mass spectrometry (ICPMS) techniques. Homogeneity testing was carried out on the bottled units and boron content along with the combined and expanded uncertainties were established. The assigned boron concentration in the In-house graphite reference material is (7.3±0.46) mg kg -1 . (author)

  20. Xyce parallel electronic simulator reference guide, version 6.1

    Energy Technology Data Exchange (ETDEWEB)

    Keiter, Eric R; Mei, Ting; Russo, Thomas V.; Schiek, Richard Louis; Sholander, Peter E.; Thornquist, Heidi K.; Verley, Jason C.; Baur, David Gregory

    2014-03-01

    This document is a reference guide to the Xyce Parallel Electronic Simulator, and is a companion document to the Xyce Users Guide [1] . The focus of this document is (to the extent possible) exhaustively list device parameters, solver options, parser options, and other usage details of Xyce. This document is not intended to be a tutorial. Users who are new to circuit simulation are better served by the Xyce Users Guide [1] .

  1. Xyce™ Parallel Electronic Simulator: Reference Guide, Version 5.1

    Energy Technology Data Exchange (ETDEWEB)

    Keiter, Eric R. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Electrical and Microsystems Modeling; Mei, Ting [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Electrical and Microsystems Modeling; Russo, Thomas V. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Electrical and Microsystems Modeling; Rankin, Eric Lamont [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Electrical and Microsystems Modeling; Schiek, Richard Louis [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Electrical and Microsystems Modeling; Santarelli, Keith R. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Electrical and Microsystems Modeling; Thornquist, Heidi K. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Electrical and Microsystems Modeling; Fixel, Deborah A. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Electrical and Microsystems Modeling; Coffey, Todd S. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Applied Mathematics and Applications; Pawlowski, Roger P. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Applied Mathematics and Applications

    2009-11-01

    This document is a reference guide to the Xyce Parallel Electronic Simulator, and is a companion document to the Xyce Users’ Guide. The focus of this document is (to the extent possible) exhaustively list device parameters, solver options, parser options, and other usage details of Xyce. This document is not intended to be a tutorial. Users who are new to circuit simulation are better served by the Xyce Users’ Guide.

  2. Xyce Parallel Electronic Simulator : reference guide, version 4.1.

    Energy Technology Data Exchange (ETDEWEB)

    Mei, Ting; Rankin, Eric Lamont; Thornquist, Heidi K.; Santarelli, Keith R.; Fixel, Deborah A.; Coffey, Todd Stirling; Russo, Thomas V.; Schiek, Richard Louis; Keiter, Eric Richard; Pawlowski, Roger Patrick

    2009-02-01

    This document is a reference guide to the Xyce Parallel Electronic Simulator, and is a companion document to the Xyce Users Guide. The focus of this document is (to the extent possible) exhaustively list device parameters, solver options, parser options, and other usage details of Xyce. This document is not intended to be a tutorial. Users who are new to circuit simulation are better served by the Xyce Users Guide.

  3. Xyce™ Parallel Electronic Simulator Reference Guide Version 6.8

    Energy Technology Data Exchange (ETDEWEB)

    Keiter, Eric R. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Aadithya, Karthik Venkatraman [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Mei, Ting [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Russo, Thomas V. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Schiek, Richard L. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Sholander, Peter E. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Thornquist, Heidi K. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Verley, Jason C. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2017-10-01

    This document is a reference guide to the Xyce Parallel Electronic Simulator, and is a companion document to the Xyce Users' Guide. The focus of this document is (to the extent possible) exhaustively list device parameters, solver options, parser options, and other usage details of Xyce . This document is not intended to be a tutorial. Users who are new to circuit simulation are better served by the Xyce Users' Guide.

  4. Xyce parallel electronic simulator reference guide, version 6.0.

    Energy Technology Data Exchange (ETDEWEB)

    Keiter, Eric R; Mei, Ting; Russo, Thomas V.; Schiek, Richard Louis; Thornquist, Heidi K.; Verley, Jason C.; Fixel, Deborah A.; Coffey, Todd S; Pawlowski, Roger P; Warrender, Christina E.; Baur, David Gregory.

    2013-08-01

    This document is a reference guide to the Xyce Parallel Electronic Simulator, and is a companion document to the Xyce Users Guide [1] . The focus of this document is (to the extent possible) exhaustively list device parameters, solver options, parser options, and other usage details of Xyce. This document is not intended to be a tutorial. Users who are new to circuit simulation are better served by the Xyce Users Guide [1] .

  5. A Reference Guide for Cryogenic Properties of Materials

    Energy Technology Data Exchange (ETDEWEB)

    Weisend, John G

    2003-09-16

    A thorough knowledge of the behavior of materials at cryogenic temperatures is critical for the design of successful cryogenic systems. Over the past 50 years, a tremendous amount of material properties at cryogenic temperatures have been measured and published. This guide lists resources for finding these properties. It covers online databases, computer codes, conference proceedings, journals, handbooks, overviews and monographs. It includes references for finding reports issued by government laboratories and agencies. Most common solids and fluids used in cryogenics are covered.

  6. Materials, Processes, and Facile Manufacturing for Bioresorbable Electronics: A Review.

    Science.gov (United States)

    Yu, Xiaowei; Shou, Wan; Mahajan, Bikram K; Huang, Xian; Pan, Heng

    2018-05-07

    Bioresorbable electronics refer to a new class of advanced electronics that can completely dissolve or disintegrate with environmentally and biologically benign byproducts in water and biofluids. They have provided a solution to the growing electronic waste problem with applications in temporary usage of electronics such as implantable devices and environmental sensors. Bioresorbable materials such as biodegradable polymers, dissolvable conductors, semiconductors, and dielectrics are extensively studied, enabling massive progress of bioresorbable electronic devices. Processing and patterning of these materials are predominantly relying on vacuum-based fabrication methods so far. However, for the purpose of commercialization, nonvacuum, low-cost, and facile manufacturing/printing approaches are the need of the hour. Bioresorbable electronic materials are generally more chemically reactive than conventional electronic materials, which require particular attention in developing the low-cost manufacturing processes in ambient environment. This review focuses on material reactivity, ink availability, printability, and process compatibility for facile manufacturing of bioresorbable electronics. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. 235Uranium isotope abundance certified reference material for gamma spectrometry EC nuclear reference material 171 certification report

    International Nuclear Information System (INIS)

    De Bievre, P.; Eschbach, H.L.; Lesser, R.; Meyer, H.; Audenhove, Van J.

    1986-01-01

    This certification report contains the information necessary for the final certification of EC nuclear reference material 171. It is also intended to inform the user of the reference material concerned on technical/scientific details which are not given in the certificate. The report describes the reference material which consists of sets of U 3 O 8 samples with five different 235 U/U abundances, filled in cylindrical aluminium cans. The can bottom serves as window for emitted gamma radiation. The report describes how the 235 U/U abundances were characterized, how the other properties relevant for gamma measurements were determined and gives all connected results as well as those from the verification measurements. Appendix A represents the draft certificate. 32 refs

  8. Noncovalent Interactions in Organic Electronic Materials

    KAUST Repository

    Ravva, Mahesh Kumar

    2017-06-29

    In this chapter, we provide an overview of how noncovalent interactions, determined by the chemical structure of π-conjugated molecules and polymers, govern essential aspects of the electronic, optical, and mechanical characteristics of organic semiconductors. We begin by describing general aspects of materials design, including the wide variety of chemistries exploited to control the electronic and optical properties of these materials. We then discuss explicit examples of how the study of noncovalent interactions can provide deeper chemical insights that can improve the design of new generations of organic electronic materials.

  9. Phosphated minerals to be used as radioactive reference materials

    International Nuclear Information System (INIS)

    Braganca, M.J.C.S.; Tauhata, L.; Clain, A.F.; Moreira, I.

    2003-01-01

    The production and the supplying of certified reference materials, or deliberated contaminated materials containing natural radionuclides for laboratories which analyses environmental samples are fundamentals for the correct measurements of their radioactive levels. This analysis quality represents a important step for the safeguards of the population health, and quality control of the imported and exported products, such as minerals, agricultural and raw materials. The phosphate rocks, containing significant concentrations of thorium, and used as raw material and fertilizers justified a study for better characterization and distinction to be used cas certified reference radioactive materials. Therefore, samples from the two carboanalytical-alkaline chimneys (Araxa and Catalao), and one from metasedimentar origin (Patos de Minas), distant 100 km from each other, were collected and chemical and cholecystographic characterized by optical emission, X-ray diffraction and fluorescence. The element concentrations were determined by neutron activation analysis, ICP-MS and ICP-AES. The results, after multivariate statistical analysis and study of correlations among elements, have shown geochemical similarities of the phosphates from Araxa and Catalao, and differences from Patos de Minas, despite of the geographic proximity. The concentration of thorium between 200 and 500 (mg/g) allows to use such minerals as reference materials

  10. Catalogue of reference materials of interest to nuclear energy

    International Nuclear Information System (INIS)

    1974-12-01

    A provisional list of available chemical, isotopic and trace elements reference materials of interest to nuclear energy has been established. Emphasis has been given to the substances containing uranium and plutonium. Certified values, sample sizes, prices and addresses of suppliers are indicated

  11. 10 CFR 433.3 - Materials incorporated by reference.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 3 2010-01-01 2010-01-01 false Materials incorporated by reference. 433.3 Section 433.3 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY STANDARDS FOR THE DESIGN AND...) 741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations...

  12. APEX (Air Pollution Exercise) Volume 20: Reference Materials.

    Science.gov (United States)

    Environmental Protection Agency, Research Triangle Park, NC. Office of Manpower Development.

    The Reference Materials Manual is part of a set of 21 manuals (AA 001 009-001 029) used in APEX (Air Pollution Exercise), a computerized college and professional level "real world" game simulation of a community with urban and rural problems, industrial activities, and air pollution difficulties. For the purposes of the gaming exercise, APEX…

  13. Determination of polybrominated diphenyl ethers in environmental standard reference materials

    Energy Technology Data Exchange (ETDEWEB)

    Stapleton, Heather M.; Schantz, Michele M.; Wise, Stephen A. [National Institute of Standards and Technology, Analytical Chemistry Division, Gaithersburg, MD (United States); Keller, Jennifer M.; Kucklick, John R. [National Institute of Standards and Technology, Analytical Chemistry Division, Hollings Marine Laboratory, Charleston, SC (United States); Leigh, Stefan D. [National Institute of Standards and Technology, Statistical Engineering Division, Gaithersburg, MD (United States)

    2007-04-15

    Standard reference materials (SRMs) are valuable tools in developing and validating analytical methods to improve quality assurance standards. The National Institute of Standards and Technology (NIST) has a long history of providing environmental SRMs with certified concentrations of organic and inorganic contaminants. Here we report on new certified and reference concentrations for 27 polybrominated diphenyl ether (PBDE) congeners in seven different SRMs: cod-liver oil, whale blubber, fish tissue (two materials), mussel tissue and sediment (two materials). PBDEs were measured in these SRMs, with the lowest concentrations measured in mussel tissue (SRM 1974b) and the highest in sediment collected from the New York/New Jersey Waterway (SRM 1944). Comparing the relative PBDE congener concentrations within the samples, we found the biota SRMs contained primarily tetrabrominated and pentabrominated diphenyl ethers, whereas the sediment SRMs contained primarily decabromodiphenyl ether (BDE 209). The cod-liver oil (SRM 1588b) and whale blubber (SRM 1945) materials were also found to contain measurable concentrations of two methoxylated PBDEs (MeO-BDEs). Certified and reference concentrations are reported for 12 PBDE congeners measured in the biota SRMs and reference values are available for two MeO-BDEs. Results from a sediment interlaboratory comparison PBDE exercise are available for the two sediment SRMs (1941b and 1944). (orig.)

  14. INAA and flame AAS of various vegetable reference materials

    International Nuclear Information System (INIS)

    Djingova, R.; Arpadjan, S.; Kuleff, I.

    1991-01-01

    INAA and flame AAS have been used for the analysis of a large number of vegetable reference materials. Out of all determined elements (28 by INAA and 11 by AAS) nine are common for both methods (Ca, Cd, Co, Cu, Fe, Mg, Mn, Na, Zn) and for these the possibilities of the two methods have been compared. (orig.)

  15. Initiative to manufacture and characterize Baculovirus Reference Material

    NARCIS (Netherlands)

    Kamen, A.; Aucoin, M.; Merten, O.W.; Alves, P.C.M.; Hashimoto, Y.; Airenne, K.; Hu, Y.C.; Mezzina, M.; Oers, van M.M.

    2011-01-01

    This letter to the editor brings to the attention of researchers an initiative to develop a baculovirus reference material repository. To be successful this initiative needs the support of a broad panel of researchers working with baculovirus vectors for recombinant protein production and gene

  16. Quality of Standard Reference Materials for Short Time Activation Analysis

    International Nuclear Information System (INIS)

    Ismail, S.S.; Oberleitner, W.

    2003-01-01

    Some environmental reference materials (CFA-1633 b, IAEA-SL-1, SARM-1,BCR-176, Coal-1635, IAEA-SL-3, BCR-146, and SRAM-5) were analysed by short-time activation analysis. The results show that these materials can be classified in three groups, according to their activities after irradiation. The obtained results were compared in order to create a quality index for determination of short-lived nuclides at high count rates. It was found that Cfta is not a suitable standard for determining very short-lived nuclides (half-lives<1 min) because the activity it produces is 15-fold higher than that SL-3. Biological reference materials, such as SRM-1571, SRM-1573, SRM-1575, SRM-1577, IAEA-392, and IAEA-393, were also investigated by a higher counting efficiency system. The quality of this system and its well-type detector for investigating short-lived nuclides was discussed

  17. Reference materials for micro-analytical nuclear techniques

    International Nuclear Information System (INIS)

    Valkovic, V.; Zeisler, R.; Bernasconi, G.; Danesi, P.R.

    1994-01-01

    Direct application of many existing reference materials in micro-analytical procedures such as energy dispersive x-ray fluorescence (EDXRF), particle induced x-ray emission spectroscopy (PIXE) and ion probe techniques for the determination of trace elements is often impossible or difficult because: 1) other constituents present in large amounts interfere with the determination; 2) trace components are not sufficiently homogeneously distributed in the sample. Therefore specific natural-matrix reference materials containing very low levels of trace elements and having high degree of homogeneity are required for many micro-analytical procedures. In this report, selection of the types of environmental and biological materials which are suitable for micro-analytical techniques will be discussed. (author)

  18. Surfaces and interfaces of electronic materials

    CERN Document Server

    Brillson, Leonard J

    2012-01-01

    An advanced level textbook covering geometric, chemical, and electronic structure of electronic materials, and their applications to devices based on semiconductor surfaces, metal-semiconductor interfaces, and semiconductor heterojunctions. Starting with the fundamentals of electrical measurements on semiconductor interfaces, it then describes the importance of controlling macroscopic electrical properties by atomic-scale techniques. Subsequent chapters present the wide range of surface and interface techniques available to characterize electronic, optical, chemical, and structural propertie

  19. Recommended reference materials for realization of physicochemical properties density

    CERN Document Server

    Herington, E F G

    1976-01-01

    This book first presents the nomenclature and units used in the determination of densities of liquids and solids, followed by a general description of the apparatus and the methods used in the measurement of density, with particular reference to the pycnometric, hydrostatic weighing, magnetic float, and temperature flotation methods. The use of water as a density reference material is then explained, focusing on the isotopic composition of Standard Mean Ocean Water (SMOW) and the absolute density of SMOW as a function of temperature. Problems due to the effect of pressure and dissolved gases o

  20. Lawrence Livermore National Laboratory Working Reference Material Production Pla

    Energy Technology Data Exchange (ETDEWEB)

    Wong, Amy; Thronas, Denise; Marshall, Robert

    1998-11-04

    This Lawrence Livermore National Laboratory (LLNL) Working Reference Material Production Plan was written for LLNL by the Los Alamos National Laboratory to address key elements of producing seven Pu-diatomaceous earth NDA Working Reference Materials (WRMS). These WRMS contain low burnup Pu ranging in mass from 0.1 grams to 68 grams. The composite Pu mass of the seven WRMS was designed to approximate the maximum TRU allowable loading of 200 grams Pu. This document serves two purposes: first, it defines all the operations required to meet the LLNL Statement of Work quality objectives, and second, it provides a record of the production and certification of the WRMS. Guidance provided in ASTM Standard Guide C1128-89 was used to ensure that this Plan addressed all the required elements for producing and certifying Working Reference Materials. The Production Plan was written to provide a general description of the processes, steps, files, quality control, and certification measures that were taken to produce the WRMS. The Plan identifies the files where detailed procedures, data, quality control, and certification documentation and forms are retained. The Production Plan is organized into three parts: a) an initial section describing the preparation and characterization of the Pu02 and diatomaceous earth materials, b) middle sections describing the loading, encapsulation, and measurement on the encapsulated WRMS, and c) final sections describing the calculations of the Pu, Am, and alpha activity for the WRMS and the uncertainties associated with these quantities.

  1. Using electron beams to investigate catalytic materials

    International Nuclear Information System (INIS)

    Zhang, Bingsen; Su, Dang Sheng

    2014-01-01

    Transmission Electron microscopy (TEM) enables us, not only to reveal the morphology, but also to provide structural, chemical and electronic information about solid catalysts at the atomic level, providing a dramatic driving force for the development of heterogeneous catalysis. Almost all catalytic materials have been studied with TEM in order to obtain information about their structures, which can help us to establish the synthesis-structure-property relationships and to design catalysts with new structures and desired properties. Herein, several examples will be reviewed to illustrate the investigation of catalytic materials by using electron beams. (authors)

  2. Gravitational Reference Sensor Front-End Electronics Simulator for LISA

    International Nuclear Information System (INIS)

    Meshksar, Neda; Ferraioli, Luigi; Mance, Davor; Zweifel, Peter; Giardini, Domenico; Ten Pierick, Jan

    2017-01-01

    At the ETH Zurich we are developing a modular simulator that provides a realistic simulation of the Front End Electronics (FEE) for LISA Gravitational Reference Sensor (GRS). It is based on the GRS FEE-simulator already implemented for LISA Pathfinder. It considers, in particular, the non-linearity and the critical details of hardware, such as the non-linear multiplicative noise caused by voltage reference instability, test mass charging and detailed actuation and sensing algorithms. We present the simulation modules, considering the above-mentioned features. Based on the ETH GRS FEE-simulator for LISA Pathfinder we aim to develop a modular simulator that provides a realistic simulation of GRS FEE for LISA. (paper)

  3. Xyce™ Parallel Electronic Simulator Reference Guide, Version 6.5

    Energy Technology Data Exchange (ETDEWEB)

    Keiter, Eric R. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Electrical Models and Simulation; Aadithya, Karthik V. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Electrical Models and Simulation; Mei, Ting [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Electrical Models and Simulation; Russo, Thomas V. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Electrical Models and Simulation; Schiek, Richard L. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Electrical Models and Simulation; Sholander, Peter E. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Electrical Models and Simulation; Thornquist, Heidi K. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Electrical Models and Simulation; Verley, Jason C. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Electrical Models and Simulation

    2016-06-01

    This document is a reference guide to the Xyce Parallel Electronic Simulator, and is a companion document to the Xyce Users’ Guide. The focus of this document is (to the extent possible) exhaustively list device parameters, solver options, parser options, and other usage details of Xyce. This document is not intended to be a tutorial. Users who are new to circuit simulation are better served by the Xyce Users’ Guide. The information herein is subject to change without notice. Copyright © 2002-2016 Sandia Corporation. All rights reserved.

  4. Developing Potential New Reference Materials for Light Isotopes in Foodstuffs

    Science.gov (United States)

    Frew, Russell; Van Hale, Robert; Clarke, Dianne; Abrahim, Aiman; Resch, Christian; Mayr, Leopold; Cannavan, Andrew; Gröning, Manfred

    2013-04-01

    Measurements of subtle variations in stable isotope ratios provide the means for verifying food integrity in numerous ways. Adulterants usually have different isotopic composition so their presence in a food is readily detectable. Stable isotope measurements can also be used to determine the region of production of the food. In most cases the ability of stable isotope measurements to verify, or otherwise reject, the authenticity of the food is greatly enhanced by comparison of a result to a reference database. The more high-quality data in the database, the more statistical power is afforded by the comparison. A serious weakness at present is the lack of reference materials in food matrices available to the community. Thus researchers have to rely on in-house standards for calibration and quality assurance. The result is that there are numerous datasets published that may be internally consistent but it is exceedingly difficult to combine these datasets into a cohesive database. This is particularly important for measurements of the hydrogen isotopes. Here we present a survey of the stable isotope (^2H, ^13C and ^15N) composition of 12 Reference Materials from the International Atomic Energy Agency catalogue. All but one of these materials are plant matter and have been developed as reference materials for other applications such as radionuclide or trace element measurements. Thus they have been verified as suitable materials in terms of stability and homogeneity for those tests. The purpose of this work is to ascertain if they are similarly suitable as stable isotope reference materials. The results from our survey show that there is a wide range in elemental and isotopic composition among these materials. For example, the ^15N values range from-13.5‰ to +18.6‰ and the nitrogen elemental composition range is from 0.7% to 9.7%. The ^13C values range from -20‰ to -40‰ and the carbon elemental composition ranges from 15% to 47%. We are now in the process of

  5. Transparent oxide electronics from materials to devices

    CERN Document Server

    Martins, Rodrigo; Barquinha, Pedro; Pereira, Luis

    2012-01-01

    Transparent electronics is emerging as one of the most promising technologies for the next generation of electronic products, away from the traditional silicon technology. It is essential for touch display panels, solar cells, LEDs and antistatic coatings. The book describes the concept of transparent electronics, passive and active oxide semiconductors, multicomponent dielectrics and their importance for a new era of novel electronic materials and products. This is followed by a short history of transistors, and how oxides have revolutionized this field. It concludes with a glance at lo

  6. Certification of a uranium dioxide reference material for chemical analyses

    International Nuclear Information System (INIS)

    Le Duigou, Y.

    1984-01-01

    This report, issued by the Central Bureau for Nuclear Measurements (CBNM), describes the characterization of a uranium dioxide reference material with accurately determined uranium mass fraction for chemical analyses. The preparation, conditioning, homogeneity tests and the analyses performed on this material are described in Annex 1. The evaluation of the individual impurity results, total of impurities and uranium mass fraction are given in Annex 2. Information on a direct determination of uranium by titration is given in Annex 3. The uranium mass fraction (881.34+-0.13) g.kg -1 calculated in Annex 2 is given on the certificate

  7. Elaboration and characterisation of plutonium waste reference materials

    International Nuclear Information System (INIS)

    Perolat, J.P.

    1990-01-01

    The Analysis Methods Establishment Commission (CETAMA) has set up a program for the elaboration and characterisation of plutonium waste reference materials. The object of this program is to give laboratories the possibility to test and calibrate apparatus used in non-destructive methods for the analysis of plutonium waste. The different parameters of this program are presented: - characterisation of plutonium, - type and number of containers, - plutonium distribution inside the different containers, - description of the matrix

  8. Prediction of total electron content using the international reference ionosphere

    International Nuclear Information System (INIS)

    Mcnamara, L.F.

    1984-01-01

    It is pointed out that the International Reference Ionosphere (IRI) is an empirical model of the ionosphere based on experimental observations. Rawer et al. (1978) have discussed the goals and status of the IRI. The aim of the IRI is related to the establishment of a compendium of height profiles through the ionosphere for the four main parameters, taking into account plasma density, temperature of ions and electrons, and ion composition. The present model is inadequate in some areas, and the IRI working group has encouraged tests of the model's validity. The present investigation is concerned with a test of the model's ability to reproduce observations of total electron content (TEC) over a wide range of conditions. The TEC observations were obtained with the aid of the Faraday rotation technique, which provides the TEC out to about 2000 km. Tests using the Bent ionospheric model indicate that the altitude range 1000 to 2000 km contributes up to five percent of the TEC. 12 references

  9. Materials and applications of bioresorbable electronics

    Science.gov (United States)

    Huang, Xian

    2018-01-01

    Bioresorbable electronics is a new type of electronics technology that can potentially lead to biodegradable and dissolvable electronic devices to replace current built-to-last circuits predominantly used in implantable devices and consumer electronics. Such devices dissolve in an aqueous environment in time periods from seconds to months, and generate biological safe products. This paper reviews materials, fabrication techniques, and applications of bioresorbable electronics, and aims to inspire more revolutionary bioresorbable systems that can generate broader social and economic impact. Existing challenges and potential solutions in developing bioresorbable electronics have also been presented to arouse more joint research efforts in this field to build systematic technology framework. Project supported by the National Natural Science Foundation of China (No. 61604108) and the Natural Science Foundation of Tianjin (No. 16JCYBJC40600).

  10. Round robin testing of thermal conductivity reference materials

    International Nuclear Information System (INIS)

    Hulstrom, L.C.; Tye, R.P.; Smith, S.E.

    1985-07-01

    The Basalt Waste Isolation Project (BWIP), operated by Rockwell Hanford Operations, has a need to determine the thermal properties of basalt in the region being considered for a nuclear waste repository in basalt. Experimental data on thermal conductivity and its variation with temperature are information required for the characterization of basalt. To establish thermal conductivity values for the reference materials, an interlaboratory measurements program was undertaken. The program was planned to meet the objectives of performing an experimental characterization of the new stock and providing a detailed analysis of the results such that reference values of thermal conductivity could be determined. This program of measurements of the thermal conductivity of Pyrex 7740 and Pyroceram 9606 has produced recommended values that are within +- 1% of those accepted previously. These measurements together with those of density indicate that the present lots of material are similar to those previously available. Pyrex 7740 and Pyroceram 9606 can continue to be used with confidence as thermal conductivity reference materials for studies on rocks and minerals and other materials of similar thermal conductivity. The uncertainty range for Pyrex 7740 and Pyroceram 9606 up to 300 0 C is +- 10.3% and +- 5.6%, respectively. This range is similar to that indicated for the previously recommended values proposed some 18 years ago. It would appear that the overall state of the art in thermal conductivity measurements for materials in this range has changed little in the intervening years. The above uncertainties, which would have been greater had not three data sets been eliminated, are greater than those which are normally claimed for each individual method. Analyses of these differences through refinements in techniques and additional measurements to higher temperatures are required. 13 refs., 7 figs., 4 tabs

  11. The role of certified reference materials in material control and accounting

    International Nuclear Information System (INIS)

    Turel, S.P.

    1979-01-01

    One way of providing an adequate material control and accounting system for the nuclear fuel cycle is to calculate material unaccounted for (MUF) after a physical inventory and to compare the limit of error of the MUF value (LEMUF) against prescribed criteria. To achieve a meaningful LEMUF, a programme for the continuing determination of systematic and random errors is necessary. Within this programme it is necessary to achieve traceability of all Special Nuclear Material (SNM) control and accounting measurements to an International/National Measurement System by means of Certified Reference Materials. SNM measurements for control and accounting are made internationally on a great variety of materials using many diverse measurement procedures by a large number of facilities. To achieve valid overall accountability over this great variety of measurements there must be some means of relating all these measurements and their uncertainties to each other. This is best achieved by an International/National Measurement System (IMS/NMS). To this end, all individual measurement systems must be compatible to the IMS/NMS and all measurement results must be traceable to appropriate international/national Primary Certified Reference Materials. To obtain this necessary compatibility for any given SNM measurement system, secondary certified reference materials or working reference materials are needed for every class of SNM and each type of measurement system. Ways to achieve ''traceability'' and the various types of certified reference material are defined and discussed in this paper. (author)

  12. Photon and electron interaction properties of ICRP reference man

    International Nuclear Information System (INIS)

    White, D.R.; Fitzgerald, M.; Ingram, D.

    1977-01-01

    The latest report of the Task Group of Committee 2 on Reference Man contains a comprehensive tabulation of the concentrations of 51 elements in 81 organs, tissues and tissue components. A comparison of the summation of the masses of the elements present in the tissue to the quoted total masses, has indicated discrepancies in excess of 20% for 12 tissues. The errors were generally due to data relating to the elements C, H, N or O being omitted, but certain skeletal systems were without calcium. Consequently, calculations were performed on 69 organs and tissues. Partial and total mass attenuation and energy absorption coefficients for 33 energies within the range 10 keV - 100 MeV, have been calculated using published elemental cross sections. Data were derived by the use of the conventional 'mixture rule', by summing over 51 elements. Photoelectric K, L 1 , L 2 and L 3 absorption edges for the high atomic number elements present were also considered in the analysis. Electron collision and radiation mass stopping powers, angular scattering powers and ranges have also been calculated for the same 33 energies from 10 keV - 100 MeV and for the same 69 tissues and organs. All of the tissues and organs have been categorised according to the basic fat/water/protein compositions and the magnitudes of the derived photon and electron data. The analysis has indicated a number of results of importance in radiation dosimetry. These include differences in excess of 30% in the photon interaction data at low energies for cortical bone compared to similar data for an earlier published formulation and significant K-edge discontinuities from iodine present in the thyroid. A review of this work will be given and comparisons made with interaction data derived from the previous reference Man document that was published in 1959. The implications of both the photon and the electron results in radiation dosimetry will be discussed

  13. Transmission Electron Microscopy and Diffractometry of Materials

    CERN Document Server

    Fultz, Brent

    2013-01-01

    This book explains concepts of transmission electron microscopy (TEM) and x-ray diffractometry (XRD) that are important for the characterization of materials. The fourth edition adds important new techniques of TEM such as electron tomography, nanobeam diffraction, and geometric phase analysis. A new chapter on neutron scattering completes the trio of x-ray, electron and neutron diffraction. All chapters were updated and revised for clarity. The book explains the fundamentals of how waves and wavefunctions interact with atoms in solids, and the similarities and differences of using x-rays, electrons, or neutrons for diffraction measurements. Diffraction effects of crystalline order, defects, and disorder in materials are explained in detail. Both practical and theoretical issues are covered. The book can be used in an introductory-level or advanced-level course, since sections are identified by difficulty. Each chapter includes a set of problems to illustrate principles, and the extensive Appendix includes la...

  14. Advanced Electron Microscopy in Materials Physics

    International Nuclear Information System (INIS)

    Zhu, Y.; Jarausch, K.

    2009-01-01

    Aberration correction has opened a new frontier in electron microscopy by overcoming the limitations of conventional round lenses, providing sub-angstrom-sized probes and extending information limits. The imaging and analytical performance of these corrector-equipped microscopes affords an unprecedented opportunity to study structure-property relationships of matter at the atomic scale. This new generation of microscopes is able to retrieve high-quality structural information comparable to neutron and synchrotron x-ray experiments, but with local atomic resolution. These advances in instrumentation are accelerating the research and development of various functional materials ranging from those for energy generation, conversion, transportation and storage to those for catalysis and nano-device applications. The dramatic improvements in electron-beam illumination and detection also present a host of new challenges for the interpretation and optimization of experiments. During 7-9 November 2007, a workshop, entitled 'Aberration Corrected Electron Microscopy in Material Physics', was convened at the Center for Functional Nanomaterials, Brookhaven National Laboratories (BNL) to address these opportunities and challenges. The workshop was co-sponsored by Hitachi High Technologies, a leader in electron microscopy instrumentation, and BNL's Institute of Advanced Electron Microscopy, a leader in materials physics research using electron microscopy. The workshop featured presentations by internationally prominent scientists working at the frontiers of electron microscopy, both on developing instrumentation and applying it in materials physics. The meeting, structured to stimulate scientific exchanges and explore new capabilities, brought together ∼100 people from over 10 countries. This special issue complies many of the advances in instrument performance and materials physics reported by the invited speakers and attendees at the workshop.

  15. Reference materials for nondestructive assay of special nuclear material. Volume 1. Uranium oxide plus graphite powder

    International Nuclear Information System (INIS)

    Sprinkle, J.K.; Likes, R.N.; Parker, J.L.; Smith, H.A.

    1983-10-01

    This manual describes the fabrication of reference materials for use in gamma-ray-based nondestructive assay of low-density uranium-bearing samples. The sample containers are 2-l bottles. The reference materials consist of small amounts of UO 2 spread throughout a graphite matrix. The 235 U content ranges from 0 to 100 g. The manual also describes the far-field assay procedure used with low-resolution detectors

  16. Runaway-electron-materials interaction studies

    International Nuclear Information System (INIS)

    Bolt, H.; Miyahara, A.

    1990-03-01

    During the operation of magnetic fusion devices it has been frequently observed that runaway electrons can cause severe damage to plasma facing components. The energy of the runaway electrons could possibly reach several 100 MeV in a next generation device with an energy content in the plasma in the order of 100 MJ. In this study effects of high energy electron - materials interaction were determined by laboratory experiments using particle beam facilities, i.e. the Electron Linear Accelerator of the Institute of Scientific and Industrial Research of Osaka University and the 10 MW Neutral Beam Injection Test Stand of the National Institute for Fusion Science. The experiments and further analyses lead to a first assessment of the damage thresholds of plasma facing materials and components under runaway electron impact. It was found that metals (stainless steel, molybdenum, tungsten) showed grain growth, crack formation and/or melting already below the threshold for crack initiation on graphite (14-33 MJ/m 2 ). Strong erosion of carbon materials would occur above 100 MJ/m 2 . Damage to metal coolant channels can occur already below an energy deposition of 100 MJ/m 2 . The energy deposited in the metal coolant channels depends on the thickness of the plasma facing carbon material D, with the shielding efficiency S of carbon approximately as S∼D 1.15 . (author) 304 refs. 12 tabs. 59 figs

  17. Dielectric materials electrization by fast electrons

    International Nuclear Information System (INIS)

    Dyrkov, V.A.; Kononov, B.A.

    1990-01-01

    Electrization of short-circuited high-ohmage targets under irradiation by 50-200 keV electrons non-uniformly by volume is investigated both experimentally and theoretically. The obtained data show that effect of space charge field increases monotonically up to stationary state during irradiation. Time constant for space charge accumulation constitutes 1-10 min and has lower value for polymethylmethacrylate as compared with polyethyleneterephthalate and decreases with increase of beam current density. Good agreement of experimental and theoretical results for both materials confirms the validity of main positions of phonomenological model of space charge formation in dielectric materials under fast electron irradiation

  18. Sustainable Materials Management (SMM) Electronics Challenge Data

    Science.gov (United States)

    On September 22, 2012, EPA launched the SMM Electronics Challenge. The Challenge encourages electronics manufacturers, brand owners and retailers to strive to send 100 percent of the used electronics they collect from the public, businesses and within their own organizations to third-party certified electronics refurbishers and recyclers. The Challenge??s goals are to: 1). Ensure responsible recycling through the use of third-party certified recyclers, 2). Increase transparency and accountability through public posting of electronics collection and recycling data, and 3). Encourage outstanding performance through awards and recognition. By striving to send 100 percent of used electronics collected to certified recyclers and refurbishers, Challenge participants are ensuring that the used electronics they collect will be responsibly managed by recyclers that maximize reuse and recycling, minimize exposure to human health and the environment, ensure the safe management of materials by downstream handlers, and require destruction of all data on used electronics. Electronics Challenge participants are publicly recognized on EPA's website as a registrant, new participant, or active participant. Awards are offered in two categories - tier and champion. Tier awards are given in recognition of achieving all the requirements under a gold, silver or bronze tier. Champion awards are given in two categories - product and non-product. For champion awards, a product is an it

  19. Progress in molecular precursors for electronic materials

    Energy Technology Data Exchange (ETDEWEB)

    Buhro, W.E. [Washington Univ., St. Louis, MO (United States)

    1996-09-01

    Molecular-precursor chemistry provides an essential underpinning to all electronic-materials technologies, including photovoltaics and related areas of direct interest to the DOE. Materials synthesis and processing is a rapidly developing field in which advances in molecular precursors are playing a major role. This article surveys selected recent research examples that define the exciting current directions in molecular-precursor science. These directions include growth of increasingly complex structures and stoichiometries, surface-selective growth, kinetic growth of metastable materials, growth of size-controlled quantum dots and quantum-dot arrays, and growth at progressively lower temperatures. Continued progress in molecular-precursor chemistry will afford precise control over the crystal structures, nanostructures, and microstructures of electronic materials.

  20. Characterization of Ricin and R. communis Agglutinin Reference Materials

    Science.gov (United States)

    Worbs, Sylvia; Skiba, Martin; Söderström, Martin; Rapinoja, Marja-Leena; Zeleny, Reinhard; Russmann, Heiko; Schimmel, Heinz; Vanninen, Paula; Fredriksson, Sten-Åke; Dorner, Brigitte G.

    2015-01-01

    Ricinus communis intoxications have been known for centuries and were attributed to the toxic protein ricin. Due to its toxicity, availability, ease of preparation, and the lack of medical countermeasures, ricin attracted interest as a potential biological warfare agent. While different technologies for ricin analysis have been established, hardly any universally agreed-upon “gold standards” are available. Expert laboratories currently use differently purified in-house materials, making any comparison of accuracy and sensitivity of different methods nearly impossible. Technically challenging is the discrimination of ricin from R. communis agglutinin (RCA120), a less toxic but highly homologous protein also contained in R. communis. Here, we established both highly pure ricin and RCA120 reference materials which were extensively characterized by gel electrophoresis, liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI MS/MS), and matrix-assisted laser desorption ionization–time of flight approaches as well as immunological and functional techniques. Purity reached >97% for ricin and >99% for RCA120. Different isoforms of ricin and RCA120 were identified unambiguously and distinguished by LC-ESI MS/MS. In terms of function, a real-time cytotoxicity assay showed that ricin is approximately 300-fold more toxic than RCA120. The highly pure ricin and RCA120 reference materials were used to conduct an international proficiency test. PMID:26703723

  1. Characterization of Ricin and R. communis Agglutinin Reference Materials

    Directory of Open Access Journals (Sweden)

    Sylvia Worbs

    2015-11-01

    Full Text Available Ricinus communis intoxications have been known for centuries and were attributed to the toxic protein ricin. Due to its toxicity, availability, ease of preparation, and the lack of medical countermeasures, ricin attracted interest as a potential biological warfare agent. While different technologies for ricin analysis have been established, hardly any universally agreed-upon “gold standards” are available. Expert laboratories currently use differently purified in-house materials, making any comparison of accuracy and sensitivity of different methods nearly impossible. Technically challenging is the discrimination of ricin from R. communis agglutinin (RCA120, a less toxic but highly homologous protein also contained in R. communis. Here, we established both highly pure ricin and RCA120 reference materials which were extensively characterized by gel electrophoresis, liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI MS/MS, and matrix-assisted laser desorption ionization–time of flight approaches as well as immunological and functional techniques. Purity reached >97% for ricin and >99% for RCA120. Different isoforms of ricin and RCA120 were identified unambiguously and distinguished by LC-ESI MS/MS. In terms of function, a real-time cytotoxicity assay showed that ricin is approximately 300-fold more toxic than RCA120. The highly pure ricin and RCA120 reference materials were used to conduct an international proficiency test.

  2. Neutron activation analysis for certification of standard reference materials

    International Nuclear Information System (INIS)

    Capote Rodriguez, G.; Perez Zayas, G.; Hernandez Rivero, A.; Ribeiro Guevara, S.

    1996-01-01

    Neutron activation analysis is used extensively as one of the analytical techniques in the certification of standard reference materials. Characteristics of neutron activation analysis which make it valuable in this role are: accuracy multielemental capability to asses homogeneity, high sensitivity for many elements, and essentially non-destructive method. This paper report the concentrations of 30 elements (major, minor and trace elements) in four Cuban samples. The samples were irradiated in a thermal neutron flux of 10 12- 10 13 n.cm 2. s -1. The gamma ray spectra were measured by HPGe detectors and were analyzed using ACTAN program development in Center of Applied Studies for Nuclear Development

  3. Reference material for trace analysis by radioanalytical methods: Bowen's Kale

    International Nuclear Information System (INIS)

    Wainerdi, R.E.

    1979-01-01

    A fairly large volume of published data on 'Bowen's Kale' has been examined critically in order to develop recommendations for the use of this preparation as a 'reference material' in the standardisation and evaluation of the reliability of analytical procedures. Values are now recommended for the contents of twelve elements present in major to trace concentrations in 'Bowen's Kale'. 'Indicated values' for another 16 elements are provided. Values for 15 more elements are listed with no recommendation. The criteria adopted in categorising elements into these groups are discussed. (author)

  4. Certification of standard reference materials employing neutron activation analysis

    International Nuclear Information System (INIS)

    Capote Rodriguez, G.; Hernandez Rivero, A.; Molina Insfran, J.; Ribeiro Guevara, S.; Santana Encinosa, C.; Perez Zayas, G.

    1997-01-01

    Neutron activation analysis (Naa) is used extensively as one of the analytical techniques in the certification of standard reference materials (Srm). Characteristics of Naa which make it valuable in this role are: accuracy; multielemental capability; ability to assess homogeneity; high sensitivity for many elements, and essentially non-destructive method. This paper reports the concentrations of thirty elements (major, minor and trace elements) in four Cuban Srm's. The samples were irradiated in a thermal neutron flux of 10 12 -10 13 neutrons.cm -2 .s -1 . The gamma-ray spectra were measured by HPGe detectors and were analysed using ACTAN program, developed in CEADEN. (author) [es

  5. Characterization of the NIST shellfish Standard Reference Material 4358

    International Nuclear Information System (INIS)

    Nour, S.; Inn, K.G.W.; Filliben, J.; Gaast van der, H.; Men, L.C.; Calmet, D.; Altzitzoglou, T.; Povinec, P.; Takata, Y.; Wisdom, M.

    2013-01-01

    A new shellfish Standard Reference Material 4358 was developed by the National Institute of Standards and Technology through an international interlaboratory comparison that involved twelve laboratories-participants from nine countries. The results from the participants were statistically evaluated, and the most robust certified values were based on the median of laboratories’ reported means and the uncertainties derived using the bootstrap method. Massic activity certified values were established for fourteen radionuclides, five activity ratios, and informational massic activity values for eight more radionuclides and two activity ratios. (author)

  6. Japanese tea leaves: a possible biological standard reference material

    International Nuclear Information System (INIS)

    Fuwa, Keiichiro; Notsu, Kenji; Tsunoda, Kin-ichi; Kato, Hideaki; Yamamoto, Yuko.

    1978-01-01

    Japanese Tea Leaves, prepared by pulverizing with an agate ball mill and sieving with a Saran fiber sieve (50 mesh) were assessed as a possible biological standard reference material for elemental analysis. The metal content of the tea leaves was determined independently at two laboratories using atomic absorption and flame emission spectrometry. Neutron activation analysis was also performed to determine the content (21 elements) of Tea Leaves. For some elements the result from the various methods were compared. The characteristics of Tea Leaves are discussed and the elemental composition is compared to that of Orchard Leaves (NBS SRM, 1571). The most significant characteristic of Tea Leaves was the high manganese content. (auth.)

  7. Need for organic reference materials in marine science

    Energy Technology Data Exchange (ETDEWEB)

    Wells, D.E.

    1988-12-01

    The reference materials (RMs) available for organic trace analysis (OTA) and the development programmes of the RM producers are reviewed. The need for a wider range of determinants, matrices and classes of RMs, particularly the more widespread use of laboratory RMs (LRMs) is discussed. Additional certified RMs should include phenolic surfactant degradation products, chlorophenolics from the wood and paper industries, and organobromines from fire retardants. RMs as molecular markers of geogenic, pyrogenic and biogenic sources; chlorophylls and xanthophylls as a measure of marine productivity and natural shellfish toxins are proposed.

  8. Halogens determination in vegetable NBS standard reference materials

    International Nuclear Information System (INIS)

    Stella, R.; Genova, N.; Di Casa, M.

    1977-01-01

    Levels of all four halogens in Orchard Leaves, Pine Needles and Tomato Leaves NBS reference standards were determined. For fluorine a spiking isotope dilution method was used followed by HF absorption on glass beads. Instrumental nuclear activation analysis was adopted for chlorine and bromine determination. Radiochemical separation by a distillation procedure was necessary for iodine nuclear activation analysis after irradiation. Activation parameters of Cl, Br and I are reported. Results of five determinations for each halogen in Orchard Leaves, Pine Needles and Tomato Leaves NBS Standard Materials and Standard deviations of the mean are reported. (T.I.)

  9. Computational Nanotechnology Molecular Electronics, Materials and Machines

    Science.gov (United States)

    Srivastava, Deepak; Biegel, Bryan A. (Technical Monitor)

    2002-01-01

    This presentation covers research being performed on computational nanotechnology, carbon nanotubes and fullerenes at the NASA Ames Research Center. Topics cover include: nanomechanics of nanomaterials, nanotubes and composite materials, molecular electronics with nanotube junctions, kinky chemistry, and nanotechnology for solid-state quantum computers using fullerenes.

  10. Xyce Parallel Electronic Simulator Reference Guide Version 6.7.

    Energy Technology Data Exchange (ETDEWEB)

    Keiter, Eric R. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Aadithya, Karthik Venkatraman [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Mei, Ting [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Russo, Thomas V. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Schiek, Richard [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Sholander, Peter E. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Thornquist, Heidi K. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Verley, Jason [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2017-05-01

    This document is a reference guide to the Xyce Parallel Electronic Simulator, and is a companion document to the Xyce Users' Guide [1] . The focus of this document is (to the extent possible) exhaustively list device parameters, solver options, parser options, and other usage details of Xyce . This document is not intended to be a tutorial. Users who are new to circuit simulation are better served by the Xyce Users' Guide [1] . The information herein is subject to change without notice. Copyright c 2002-2017 Sandia Corporation. All rights reserved. Trademarks Xyce TM Electronic Simulator and Xyce TM are trademarks of Sandia Corporation. Orcad, Orcad Capture, PSpice and Probe are registered trademarks of Cadence Design Systems, Inc. Microsoft, Windows and Windows 7 are registered trademarks of Microsoft Corporation. Medici, DaVinci and Taurus are registered trademarks of Synopsys Corporation. Amtec and TecPlot are trademarks of Amtec Engineering, Inc. All other trademarks are property of their respective owners. Contacts World Wide Web http://xyce.sandia.gov https://info.sandia.gov/xyce (Sandia only) Email xyce@sandia.gov (outside Sandia) xyce-sandia@sandia.gov (Sandia only) Bug Reports (Sandia only) http://joseki-vm.sandia.gov/bugzilla http://morannon.sandia.gov/bugzilla

  11. Electronic Structure of Strongly Correlated Materials

    CERN Document Server

    Anisimov, Vladimir

    2010-01-01

    Electronic structure and physical properties of strongly correlated materials containing elements with partially filled 3d, 4d, 4f and 5f electronic shells is analyzed by Dynamical Mean-Field Theory (DMFT). DMFT is the most universal and effective tool used for the theoretical investigation of electronic states with strong correlation effects. In the present book the basics of the method are given and its application to various material classes is shown. The book is aimed at a broad readership: theoretical physicists and experimentalists studying strongly correlated systems. It also serves as a handbook for students and all those who want to be acquainted with fast developing filed of condensed matter physics.

  12. Xyce Parallel Electronic Simulator Reference Guide Version 6.4

    Energy Technology Data Exchange (ETDEWEB)

    Keiter, Eric R. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Mei, Ting [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Russo, Thomas V. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Schiek, Richard [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Sholander, Peter E. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Thornquist, Heidi K. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Verley, Jason [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Baur, David Gregory [Raytheon, Albuquerque, NM (United States)

    2015-12-01

    This document is a reference guide to the Xyce Parallel Electronic Simulator, and is a companion document to the Xyce Users' Guide [1] . The focus of this document is (to the extent possible) exhaustively list device parameters, solver options, parser options, and other usage details of Xyce . This document is not intended to be a tutorial. Users who are new to circuit simulation are better served by the Xyce Users' Guide [1] . Trademarks The information herein is subject to change without notice. Copyright c 2002-2015 Sandia Corporation. All rights reserved. Xyce TM Electronic Simulator and Xyce TM are trademarks of Sandia Corporation. Portions of the Xyce TM code are: Copyright c 2002, The Regents of the University of California. Produced at the Lawrence Livermore National Laboratory. Written by Alan Hindmarsh, Allan Taylor, Radu Serban. UCRL-CODE-2002-59 All rights reserved. Orcad, Orcad Capture, PSpice and Probe are registered trademarks of Cadence Design Systems, Inc. Microsoft, Windows and Windows 7 are registered trademarks of Microsoft Corporation. Medici, DaVinci and Taurus are registered trademarks of Synopsys Corporation. Amtec and TecPlot are trademarks of Amtec Engineering, Inc. Xyce 's expression library is based on that inside Spice 3F5 developed by the EECS Department at the University of California. The EKV3 MOSFET model was developed by the EKV Team of the Electronics Laboratory-TUC of the Technical University of Crete. All other trademarks are property of their respective owners. Contacts Bug Reports (Sandia only) http://joseki.sandia.gov/bugzilla http://charleston.sandia.gov/bugzilla World Wide Web http://xyce.sandia.gov http://charleston.sandia.gov/xyce (Sandia only) Email xyce@sandia.gov (outside Sandia) xyce-sandia@sandia.gov (Sandia only)

  13. Electronic Transport in Two-Dimensional Materials

    Science.gov (United States)

    Sangwan, Vinod K.; Hersam, Mark C.

    2018-04-01

    Two-dimensional (2D) materials have captured the attention of the scientific community due to the wide range of unique properties at nanometer-scale thicknesses. While significant exploratory research in 2D materials has been achieved, the understanding of 2D electronic transport and carrier dynamics remains in a nascent stage. Furthermore, because prior review articles have provided general overviews of 2D materials or specifically focused on charge transport in graphene, here we instead highlight charge transport mechanisms in post-graphene 2D materials, with particular emphasis on transition metal dichalcogenides and black phosphorus. For these systems, we delineate the intricacies of electronic transport, including band structure control with thickness and external fields, valley polarization, scattering mechanisms, electrical contacts, and doping. In addition, electronic interactions between 2D materials are considered in the form of van der Waals heterojunctions and composite films. This review concludes with a perspective on the most promising future directions in this fast-evolving field.

  14. Preparation, characterization and certification of uranium isotope reference materials

    International Nuclear Information System (INIS)

    Oliveira Junior, Olivio Pereira de

    2006-01-01

    This work describes the preparation, characterization and certification of a set of uranium isotope reference materials ranging from 0.5 to 20.0 % of 235 U in mass. The most important concepts of metrology in chemical measurements were applied so that the certified quantities in these materials could be directly traceable to the International System of Units (SI). As a consequence of this approach, these materials can be used in the instruments calibration, estimation of measurement uncertainty, method validation, assessment of performance of analysts, quality control routines and interlaboratory comparison programmes. The most advanced methods and techniques in mass spectrometry, that is, gas source mass spectrometry (GSMS), thermal ionisation mass spectrometry (TIMS) and inductively coupled plasma mass spectrometry (ICPMS) were investigated to identify which are the dominant components in the uncertainty and to quantify its contribution to the final value of the measurement uncertainty of the isotopic ratio. The results obtained were then compared to verify which are the methods and techniques associated to the lowest measurement uncertainty values. The isotope amount ratio n( 235 U)/n( 238 U) was certified in the materials produced to expanded uncertainties ranging from 0.02 to 0.10 % and the ratios n( 234 U)/n( 238 U) and n( 236 U)/n( 238 U), to uncertainties ranging from 0.03 to 2.20 %. These values fully comply to the requirements of the isotopic characterization of nuclear fuel as well as the analysis of environmental samples for nuclear safeguards. (author)

  15. Electrodynamics in Arbitrary Reference Frames and in Arbitrary Material Media

    International Nuclear Information System (INIS)

    Horzela, A.; Kapuscik, E.; Widomski, M.

    1999-01-01

    Full text: The investigation of electromagnetic phenomena in material media still belongs to the most difficult tasks of electrodynamics. Complexity and variability of material media practically exclude effective applications of methods and computational techniques elaborated in the framework of standard microscopic electrodynamics with classical vacuum as a ground state. In order to obtain satisfactorily exact descriptions of electromagnetic properties of complex material media one is enforced to use methods and approximations which are difficult to control. Moreover, they usually break covariance properties and the results obtained are valid in one reference frame which choice remains subjective and model dependent. Some time ago we have proposed a reformulation of Maxwell electrodynamics which opens new ways in study of electromagnetic processes in material media. The formalism gets rid of assumptions characteristic for vacuum electrodynamics only and it avoids the usage of constitutive relations as primary relations put on quantities needed for a complete description of an electromagnetic system. Fundamental properties of all electromagnetic quantities are their uniquely defined transformation rules and their analysis allows to determine the possible relations between them. Within such a scheme it is possible to introduce constitutive relations which do not have analogies in macroscopic classical electrodynamics. They may be used in description of microscopic electromagnetic processes in a different way than it is done in the framework of quantum electrodynamics. (author)

  16. Consensus values for NIST biological and environmental Standard Reference Materials

    International Nuclear Information System (INIS)

    Roelandts, I.; Gladney, E.S.

    1998-01-01

    The National Institute of Standards and Technology (NIST, formerly the National Bureau of Standards or NBS) has produced numerous Standard Reference Materials (SRM) for use in biological and environmental analytical chemistry. The value listed on the ''NIST Certificate of Analysis'' is the present best estimate of the ''true'' concentration of that element and is not expected to deviate from that concentration by more than the stated uncertainty. However, NIST does not certify the elemental concentration of every constituent and the number of elements reported in the NIST programs tends to be limited.Numerous analysts have published concentration data on these reference materials. Major journals in analytical chemistry, books, proceedings and ''technical reports'' have been surveyed to collect these available literature values. A standard statistical approach has been employed to evaluate the compiled data. Our methodology has been developed in a series of previous papers. Some subjective criteria are first used to reject aberrant data. Following these eliminations, an initial arithmetic mean and standard deviation (S.D.) are computed from remaining data for each element. All data now outside two S.D. from the initial mean are dropped and a second mean and S.D. recalculated. These final means and associated S.D. are reported as ''consensus values'' in our tables. (orig.)

  17. Reference Material IAEA 434: Naturally Occurring Radionuclides in Phosphogypsum

    International Nuclear Information System (INIS)

    2010-01-01

    Phosphogypsum is generated as a by-product of the phosphoric acid based fertilizer industry. The discharge of phosphogypsum on earth surface deposits is a potential source of enhanced natural radiation and heavy metals, and the resulting environmental impact should be considered carefully to ensure safety and compliance with environmental regulations. In addition, phosphogypsum can be used to make several building materials and it is used in agriculture as a conditioner to maintain soil productivity in areas where soils are poor and erode easily. A reliable determination of naturally occurring radionuclides in phosphogypsum is necessary to comply with the radiation protection and environmental regulations. The IAEA-434 will assist laboratories in the IAEA Member States in validating their analytical methods for the determination of naturally occurring radionuclides in phosphogypsum and to control the quality of the produced analytical results. Reference values for the massic activities and associated standard uncertainties were established for: Pb-210, Ra-226, Th-230, U-234 and U-238. During sample production and certification, the requirements for reference material production and certification as stated in ISO guides 34 and 35 were taken into account. This report summarizes the preparation and certification process

  18. Determination of sampling constants in NBS geochemical standard reference materials

    International Nuclear Information System (INIS)

    Filby, R.H.; Bragg, A.E.; Grimm, C.A.

    1986-01-01

    Recently Filby et al. showed that, for several elements, National Bureau of Standards (NBS) Fly Ash standard reference material (SRM) 1633a was a suitable reference material for microanalysis (sample weights 2 , and the mean sample weight, W vector, K/sub s/ = (S/sub s/%) 2 W vector, could not be determined from these data because it was not possible to quantitate other sources of error in the experimental variances. K/sub s/ values for certified elements in geochemical SRMs provide important homogeneity information for microanalysis. For mineralogically homogeneous SRMs (i.e., small K/sub s/ values for associated elements) such as the proposed clays, it is necessary to determine K/sub s/ by analysis of very small sample aliquots to maximize the subsampling variance relative to other sources of error. This source of error and the blank correction for the sample container can be eliminated by determining K/sub s/ from radionuclide activities of weighed subsamples of a preirradiated SRM

  19. Photoemission for f-electron materials

    International Nuclear Information System (INIS)

    Huang, Youngsea.

    1989-01-01

    The dissertation investigates the interpretation of photoemission from f-electron materials. The authors also discuss unusual room temperature solid-state reactions in Yb-Cu films that they discovered. They show the importance of considering the entire system in the photoemission process and that photoemission actually measures the energy difference between total energies of the initial state and the final excited state of the whole system. They point out misconceptions in the current interpretation of photoemission from mixed valent materials. Their results on Yb-Cu system and other high-resolution photoemission measurements on mixed valent Yb-based materials show that the 4f feature is not pinned at the Fermi level though there is a 4f 14 (6s5d) 2 and 4f 13 (6s5d) 3 configuration degeneracy in the ground state. They suggest that this non-pinning is a general phenomenon due to the fact that the final state is not completely relaxed in the photoemission process. They discuss the current competing models of photoemission from Ce-based materials and show problems with their interpretations. As 4f electrons are more itinerant for Ce and Yb, they give a delocalized-localized kind of interpretation for 4f levels of Ce based materials. They employ the Ce-Yb analogy (electron-hole inversion and thereby an energy scale inversion) with the impurity model to photoemission from Yb-based materials and point out contradictory results on YbAl 3 in the literature. In their results on the Yb-Cu system, where the Yb valence varies from ∼3 to ∼2.2, they do not observe the Kondo resonance within the limits of their experimental resolution. They suggest that to date no Kondo resonance has been observed, and speculate either that the impurity model is inadequate for Yb-based materials or that photoemission is unable to detect a Kondo resonance

  20. A comparison of chemical reference materials for solution calorimeters.

    Science.gov (United States)

    Ramos, Rita; Gaisford, Simon; Buckton, Graham; Royall, Paul G; Yff, Barbara T S; O'Neill, Michael A A

    2005-08-11

    Solution calorimeters are based on semi-adiabatic or isothermal heat-conduction principles and differ in the way they record data. They also have different measuring sensitivities and require different quantities of solute and solvent. As such, the choice of chemical test substance is not straightforward. Usually the dilution of KCl is recommended; it is possible to purchase a reference sample of KCl that has a certified enthalpy of solution and this standard material is usually used to test semi-adiabatic instruments. Here, we review the suitability of a range of chemical test substances (KCl, sucrose and Tris) for an isothermal heat-conduction solution calorimeter. It was found that KCl was not the best test material because its relatively high enthalpy of solution (DeltasolH) necessitated the use of small samples (2 mg), resulting in a relatively large standard deviation (sigman-1) in the values recorded (DeltasolH=17.14+/-0.49 kJ mol-1); furthermore, KCl data must be corrected to account for the effect of dilution, although the correction was found to be small (0.07 kJ mol-1) under the experimental conditions employed here. Sucrose appears to be a much more robust test material for isothermal heat-conduction instruments because its lower enthalpy of solution allows the use of much larger samples (20 mg), which minimises experimental errors. The DeltasolH value returned (6.14+/-0.08 kJ mol-1) is in excellent agreement with the literature. It is also cheap, readily available and requires minimal preparation although its widespread use would require the preparation of a certified reference sample.

  1. Nonlinearity in structural and electronic materials

    International Nuclear Information System (INIS)

    Bishop, A.R.; Beardmore, K.M.; Ben-Naim, E.

    1997-01-01

    This is the final report of a three-year, Laboratory Directed Research and Development (LDRD) project at the Los Alamos National Laboratory (LANL). The project strengthens a nonlinear technology base relevant to a variety of problems arising in condensed matter and materials science, and applies this technology to those problems. In this way the controlled synthesis of, and experiments on, novel electronic and structural materials provide an important focus for nonlinear science, while nonlinear techniques help advance the understanding of the scientific principles underlying the control of microstructure and dynamics in complex materials. This research is primarily focused on four topics: (1) materials microstructure: growth and evolution, and porous media; (2) textures in elastic/martensitic materials; (3) electro- and photo-active polymers; and (4) ultrafast photophysics in complex electronic materials. Accomplishments included the following: organization of a ''Nonlinear Materials'' seminar series and international conferences including ''Fracture, Friction and Deformation,'' ''Nonequilibrium Phase Transitions,'' and ''Landscape Paradigms in Physics and Biology''; invited talks at international conference on ''Synthetic Metals,'' ''Quantum Phase Transitions,'' ''1996 CECAM Euroconference,'' and the 1995 Fall Meeting of the Materials Research Society; large-scale simulations and microscopic modeling of nonlinear coherent energy storage at crack tips and sliding interfaces; large-scale simulation and microscopic elasticity theory for precursor microstructure and dynamics at solid-solid diffusionless phase transformations; large-scale simulation of self-assembling organic thin films on inorganic substrates; analysis and simulation of smoothing of rough atomic surfaces; and modeling and analysis of flux pattern formation in equilibrium and nonequilibrium Josephson junction arrays and layered superconductors

  2. Xyce Parallel Electronic Simulator Reference Guide Version 6.6.

    Energy Technology Data Exchange (ETDEWEB)

    Keiter, Eric R. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Aadithya, Karthik Venkatraman [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Mei, Ting [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Russo, Thomas V. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Schiek, Richard [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Sholander, Peter E. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Thornquist, Heidi K. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Verley, Jason [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2016-11-01

    This document is a reference guide to the Xyce Parallel Electronic Simulator, and is a companion document to the Xyce Users' Guide [1] . The focus of this document is (to the extent possible) exhaustively list device parameters, solver options, parser options, and other usage details of Xyce . This document is not intended to be a tutorial. Users who are new to circuit simulation are better served by the Xyce Users' Guide [1] . The information herein is subject to change without notice. Copyright c 2002-2016 Sandia Corporation. All rights reserved. Acknowledgements The BSIM Group at the University of California, Berkeley developed the BSIM3, BSIM4, BSIM6, BSIM-CMG and BSIM-SOI models. The BSIM3 is Copyright c 1999, Regents of the University of California. The BSIM4 is Copyright c 2006, Regents of the University of California. The BSIM6 is Copyright c 2015, Regents of the University of California. The BSIM-CMG is Copyright c 2012 and 2016, Regents of the University of California. The BSIM-SOI is Copyright c 1990, Regents of the University of California. All rights reserved. The Mextram model has been developed by NXP Semiconductors until 2007, Delft University of Technology from 2007 to 2014, and Auburn University since April 2015. Copyrights c of Mextram are with Delft University of Technology, NXP Semiconductors and Auburn University. The MIT VS Model Research Group developed the MIT Virtual Source (MVS) model. Copyright c 2013 Massachusetts Institute of Technology (MIT). The EKV3 MOSFET model was developed by the EKV Team of the Electronics Laboratory-TUC of the Technical University of Crete. Trademarks Xyce TM Electronic Simulator and Xyce TM are trademarks of Sandia Corporation. Orcad, Orcad Capture, PSpice and Probe are registered trademarks of Cadence Design Systems, Inc. Microsoft, Windows and Windows 7 are registered trademarks of Microsoft Corporation. Medici, DaVinci and Taurus are registered trademarks of Synopsys Corporation. Amtec and Tec

  3. Polymeric materials obtained by electron beam irradiation

    International Nuclear Information System (INIS)

    Dragusin, M.; Moraru, R.; Martin, D.; Radoiu, M.; Marghitu, S.; Oproiu, C.

    1995-01-01

    Research activities in the field of electron beam irradiation of monomer aqueous solution to produce polymeric materials used for waste waters treatment, agriculture and medicine are presented. The technologies and special features of these polymeric materials are also described. The influence of the chemical composition of the solution to ba irradiated, absorbed dose level and absorbed dose rate level are discussed. Two kinds of polyelectrolytes, PA and PV types and three kinds of hydrogels, pAAm, pAAmNa and pNaAc types, the production of which was first developed with IETI-10000 Co-60 source and then adapted to the linacs built in Accelerator Laboratory, are described. (author)

  4. Scalar material reference systems and loop quantum gravity

    International Nuclear Information System (INIS)

    Giesel, K; Thiemann, T

    2015-01-01

    In the past, the possibility to employ (scalar) material reference systems in order to describe classical and quantum gravity directly in terms of gauge invariant (Dirac) observables has been emphasized frequently. This idea has been picked up more recently in loop quantum gravity with the aim to perform a reduced phase space quantization of the theory, thus possibly avoiding problems with the (Dirac) operator constraint quantization method for a constrained system. In this work, we review the models that have been studied on the classical and/or the quantum level and parametrize the space of theories considered so far. We then describe the quantum theory of a model that, to the best of our knowledge, has only been considered classically so far. This model could arguably be called the optimal one in this class of models considered as it displays the simplest possible true Hamiltonian, while at the same time reducing all constraints of general relativity. (paper)

  5. Iodine in different food articles and standard reference materials

    International Nuclear Information System (INIS)

    Dermelj, M.; Slejkovec, Z.; Byrne, A.R.; Stegnar, P.; Stibilj, V.; Rossbach, M.

    1990-01-01

    The greater part of essential iodine enters living organisms via the food chain. Nevertheless, quantitative data on its concentration in diets, food articles and also in available SRMs are very poor and scarce. This and WHO recommendations on daily allowances of iodine for man via food articles caused an added demand for accurate and reliable determination of iodine in these samples. From this point of view the purpose of the present was to analyse and to establish the concentration levels of total iodine in some food articles, diets, SRMs and candidate reference materials by the use of rapid radiochemical separation, developed in our laboratory. The results were checked by the analysis of SRMs with available certified values for iodine and good agreement is evident. (orig.)

  6. Neutron activation analysis of new botanical reference materials. Pt. 2

    International Nuclear Information System (INIS)

    Kucera, J.; Soukal, L.

    1993-01-01

    The certified, information, and other values of elemental contents were compared with results of neutron activation analysis (NAA) for the new Czechoslovak botanical reference materials (RMs) Green Algae 12-02-02, Lucerne 12-02-03, Wheat Bread Fluor 12-02-04, and Rye Bread Flour 12-02-05. These were prepared by the Institute of Radioecology and Applied Nuclear Techniques (IRANT), Kosice, and statistically evaluated after interlaboratory comparisons. For the majority of elements, a very good agreement was found between the IRANT values and the results of NAA. In several cases, however, significant differences were detected; possible analytical reasons for the differences and the suitability of a purely statistical evaluation of intercomparison results without analytical considerations for RM certification are discussed. (orig.)

  7. Development of the NBS beryllium isotopic standard reference material

    International Nuclear Information System (INIS)

    Inn, K.G.W; Fassett, J.D.; Coursey, B.M.; Walker, R.L.; Raman, S.

    1987-01-01

    The National Bureau of Standards, in conjunction with the Oak Ridge National Laboratory and the Accelerator Mass Spectrometry community, is in the process of developing a beryllium isotopic solution Standard Reference Material. The master 10 Be/ 9 Be solution was characterized isotopically by resonance-ionization and secondary-ion mass-spectrometric-based techniques, and radioactivity measurements were by liquid scintillation counting. The master solution was gravimetrically diluted with 9 Be to a final 10 Be/ 9 Be atomic ratio of 3 x 10 -11 . The preliminary data indicate a half life for 10 Be of 1.3 million years, and AMS measurements are within 10% of the known beryllium isotopic ratio

  8. Bias detection and certified reference materials for random measurands

    Science.gov (United States)

    Rukhin, Andrew L.

    2015-12-01

    A problem that frequently occurs in metrology is the bias checking of data obtained by a laboratory against the specified value and uncertainty estimate given in the certificate of analysis. The measurand—a property of a certified reference material (CRM)—is supposed to be random with a normal distribution whose parameters are given by the certificate specifications. The laboratory’s data from subsequent measurements of the CRM (a CRM experiment) are summarized by the sample mean value and its uncertainty which is commonly based on a repeatability standard deviation. New confidence intervals for the lab’s bias are derived. Although they may lack intuitive appeal, those obtained by using higher order asymptotic methods, compared and contrasted in this paper, are recommended.

  9. INAA Application for Trace Element Determination in Biological Reference Material

    Science.gov (United States)

    Atmodjo, D. P. D.; Kurniawati, S.; Lestiani, D. D.; Adventini, N.

    2017-06-01

    Trace element determination in biological samples is often used in the study of health and toxicology. Determination change to its essentiality and toxicity of trace element require an accurate determination method, which implies that a good Quality Control (QC) procedure should be performed. In this study, QC for trace element determination in biological samples was applied by analyzing the Standard Reference Material (SRM) Bovine muscle 8414 NIST using Instrumental Neutron Activation Analysis (INAA). Three selected trace element such as Fe, Zn, and Se were determined. Accuracy of the elements showed as %recovery and precision as %coefficient of variance (%CV). The result showed that %recovery of Fe, Zn, and Se were in the range between 99.4-107%, 92.7-103%, and 91.9-112%, respectively, whereas %CV were 2.92, 3.70, and 5.37%, respectively. These results showed that INAA method is precise and accurate for trace element determination in biological matrices.

  10. The ETH Zurich AMS facilities: Performance parameters and reference materials

    Energy Technology Data Exchange (ETDEWEB)

    Christl, M., E-mail: mchristl@phys.ethz.ch [Laboratory of Ion Beam Physics, ETH Zurich, 8093 Zurich (Switzerland); Vockenhuber, C.; Kubik, P.W.; Wacker, L.; Lachner, J.; Alfimov, V.; Synal, H.-A. [Laboratory of Ion Beam Physics, ETH Zurich, 8093 Zurich (Switzerland)

    2013-01-15

    The current performance of all three AMS systems in operation at ETH Zurich, the 6 MV HVEC EN-Tandem facility 'TANDEM', the 0.5 MV NEC Pelletron 'TANDY', and the 0.2 MV system 'MICADAS' is summarized. Radionuclides routinely measured with these AMS systems include {sup 10}Be, {sup 14}C, {sup 26}Al, {sup 36}Cl, {sup 41}Ca, {sup 129}I and the actinides. The reference materials used for the normalization of the AMS measurements at the ETH Zurich AMS facilities are presented. This paper therefore is a comprehensive status report of all three AMS systems currently operated by the Laboratory of Ion Beam Physics (LIP) at ETH Zurich and documents their performance and operation parameters.

  11. Synaptic electronics: materials, devices and applications.

    Science.gov (United States)

    Kuzum, Duygu; Yu, Shimeng; Wong, H-S Philip

    2013-09-27

    In this paper, the recent progress of synaptic electronics is reviewed. The basics of biological synaptic plasticity and learning are described. The material properties and electrical switching characteristics of a variety of synaptic devices are discussed, with a focus on the use of synaptic devices for neuromorphic or brain-inspired computing. Performance metrics desirable for large-scale implementations of synaptic devices are illustrated. A review of recent work on targeted computing applications with synaptic devices is presented.

  12. Synaptic electronics: materials, devices and applications

    International Nuclear Information System (INIS)

    Kuzum, Duygu; Yu, Shimeng; Philip Wong, H-S

    2013-01-01

    In this paper, the recent progress of synaptic electronics is reviewed. The basics of biological synaptic plasticity and learning are described. The material properties and electrical switching characteristics of a variety of synaptic devices are discussed, with a focus on the use of synaptic devices for neuromorphic or brain-inspired computing. Performance metrics desirable for large-scale implementations of synaptic devices are illustrated. A review of recent work on targeted computing applications with synaptic devices is presented. (topical review)

  13. Electron microscopy of nanostructured semiconductor materials

    International Nuclear Information System (INIS)

    Neumann, Wolfgang

    2003-01-01

    For various material systems of low dimensions, including multilayers, islands, and quantum dots, the potential applicability of transmission electron microscopy (TEM) is demonstrated. Conventional TEM is applied to elucidate size, shape, and arrangement of nanostructures, whereas high-resolution imaging is used for visualizing their atomic structure. In addition, microchemical peculiarities of the nanoscopic objects are investigated by analytical TEM techniques (energy-filtered TEM, energy-dispersive X-ray spectroscopy)

  14. IAEA reference materials for quality assurance of marine radioactivity measurements

    International Nuclear Information System (INIS)

    Povinec, P.P.; Pham, M.K.

    2001-01-01

    The IAEA's Marine Environment Laboratory has been assisting laboratories in Analytical Quality Control Services (AQCS) for the analysis of radionuclides in the marine environment since the early seventies. AQCS through world-wide and regional intercomparison exercises and the provision of reference methods and reference materials (RM) have been recognized as an important component of quality assurance/quality control. A total of 43 intercomparison exercises were organized and 37 RM were produced for marine radioactivity studies. All important marine matrices were covered, e.g., seawater, marine sediments of different chemical compositions, fish, shellfish and seaplants. RM were prepared from samples collected at contaminated sites (e.g., the Irish Sea, the Baltic Sea, the Arabian Sea, Mururoa and Bikini Atolls, etc.) as well as from sites affected only by global fallout (e.g., the Pacific Ocean). Available RM are listed in the IAEA biennial catalogue and can be purchased at a minimal price. An overview of prepared RM for radionuclides in marine matrices is presented and discussed in more detail. (author)

  15. Production of Working Reference Materials for the Capability Evaluation Project

    Energy Technology Data Exchange (ETDEWEB)

    Phillip D. Noll, Jr.; Robert S. Marshall

    1999-03-01

    Nondestructive waste assay (NDA) methods are employed to determine the mass and activity of waste-entrained radionuclides as part of the National TRU (Trans-Uranic) Waste Characterization Program. In support of this program the Idaho National Engineering and Environmental Laboratory Mixed Waste Focus Area developed a plan to acquire capability/performance data on systems proposed for NDA purposes. The Capability Evaluation Project (CEP) was designed to evaluate the NDA systems of commercial contractors by subjecting all participants to identical tests involving 55 gallon drum surrogates containing known quantities and distributions of radioactive materials in the form of sealed-source standards, referred to as working reference materials (WRMs). Although numerous Pu WRMs already exist, the CEP WRM set allows for the evaluation of the capability and performance of systems with respect to waste types/configurations which contain increased amounts of {sup 241}Am relative to weapons grade Pu, waste that is dominantly {sup 241}Am, as well as wastes containing various proportions of depleted uranium. The CEP WRMs consist of a special mixture of PuO{sub 2}/AmO{sub 2} (IAP) and diatomaceous earth (DE) or depleted uranium (DU) oxide and DE and were fabricated at Los Alamos National Laboratory. The IAP WRMS are contained inside a pair of welded inner and outer stainless steel containers. The DU WRMs are singly contained within a stainless steel container equivalent to the outer container of the IAP standards. This report gives a general overview and discussion relating to the production and certification of the CEP WRMs.

  16. New Carbonate Standard Reference Materials for Boron Isotope Geochemistry

    Science.gov (United States)

    Stewart, J.; Christopher, S. J.; Day, R. D.

    2015-12-01

    The isotopic composition of boron (δ11B) in marine carbonates is well established as a proxy for past ocean pH. Yet, before palaeoceanographic interpretation can be made, rigorous assessment of analytical uncertainty of δ11B data is required; particularly in light of recent interlaboratory comparison studies that reported significant measurement disagreement between laboratories [1]. Well characterised boron standard reference materials (SRMs) in a carbonate matrix are needed to assess the accuracy and precision of carbonate δ11B measurements throughout the entire procedural chemistry; from sample cleaning, to ionic separation of boron from the carbonate matrix, and final δ11B measurement by multi-collector inductively coupled plasma mass spectrometry. To date only two carbonate reference materials exist that have been value-assigned by the boron isotope measurement community [2]; JCp-1 (porites coral) and JCt-1 (Giant Clam) [3]. The National Institute of Standards and Technology (NIST) will supplement these existing standards with new solution based inorganic carbonate boron SRMs that replicate typical foraminiferal and coral B/Ca ratios and δ11B values. These new SRMs will not only ensure quality control of full procedural chemistry between laboratories, but have the added benefits of being both in abundant supply and free from any restrictions associated with shipment of biogenic samples derived from protected species. Here we present in-house δ11B measurements of these new boron carbonate SRM solutions. These preliminary data will feed into an interlaboratory comparison study to establish certified values for these new NIST SRMs. 1. Foster, G.L., et al., Chemical Geology, 2013. 358(0): p. 1-14. 2. Gutjahr, M., et al., Boron Isotope Intercomparison Project (BIIP): Development of a new carbonate standard for stable isotopic analyses. Geophysical Research Abstracts, EGU General Assembly 2014, 2014. 16(EGU2014-5028-1). 3. Inoue, M., et al., Geostandards and

  17. Use of neutron activation in dietary reference material analysis

    Energy Technology Data Exchange (ETDEWEB)

    Woittiez, J R.W.; Iyengar, G V

    1988-12-01

    Results for a number of trace elements in a total human diet material (USDIET-1), obtained by the application of both INAA and RNAA are presented. Several dietary reference materials such as NBS SRM 1577A, and BCR CRM Single Cell Protein were also analyzed, and these results are also given. Combining measurements on short and long lived radionuclides, the INAA approach is useful for the determination of about 20 elements. In order to expand the elemental coverage or improve detection limits, RNAA was also explored in two modes: separation of radionuclides using organic ion exchange resins and the use of hydrated manganese dioxide. This combination is applicable to 15 trace elements. For example, using RNAA, the following results were obtained for USDIET-1: Cd=31.8, Mo=280, Cr=71, Ag=4, As=117 and Sb=9.4 ..mu..g/kg. In the INAA mode, special attention was given to Al, F and Se. The F content of USDIET-1 was found to be 840 mg/kg, a rather high value, resulting from handling USDIET-1 by Teflon tools. By applying INAA and RNAA under two different laboratory conditions, it has been demonstrated that, even for the so-called difficult to determine elements like Cr, As or Mo, consistent results can be obtained. Thus, NAA promises to be a strong tool for human nutritional studies.

  18. Reference materials and interlaboratory comparison for actinide analysis

    International Nuclear Information System (INIS)

    Hanssens, Alain; Viallesoubranne, Carole; Roche, Claude; Liozon, Gerard

    2008-01-01

    Measurement quality is crucial for the safety of nuclear facilities and is a primary requirement for fissile material monitoring and accountancy. CETAMA (Cea Committee for the establishment of analysis methods), in collaboration with Cea and AREVA laboratories, fabricates certified reference materials and organizes interlaboratory comparison programs for plutonium and uranium assay in solution. A new plutonium metal measurement standard (MP3) is currently being prepared by Cea and is a subject of cooperative work in view of its certification and use by analysis laboratories. U and Pu interlaboratory comparisons are carried out at regular intervals on benchmark samples in coordination with working groups from French nuclear laboratories. These programs are supported by international cooperation. 'Chemical' methods (potentiometry, gravimetric analysis, etc.) generally provide the best accuracy. Coulometry is the benchmark technique for plutonium assay: its metrological qualities should be an incentive for wider use by laboratories performing precise control assays of plutonium as well as uranium. Gravimetric analysis provides excellent results for analysis of pure uranyl nitrate solutions. In view of its many advantages we encourage laboratories to employ this technique to assay pure U or Pu solutions. 'Physical' or 'physicochemical' methods are increasingly used, and their performance has improved. K-edge absorption spectrometry and isotope dilution mass spectrometry are capable of reaching measurement quality levels comparable to those of the best 'chemical' methods. (authors)

  19. Reactor neutron activation analysis on reference materials from intercomparison runs

    International Nuclear Information System (INIS)

    Pantelica, A.; Salagean, M.

    2003-01-01

    A review of using the Instrumental Neutron Activation Analysis (INAA) technique in our laboratory to determine major, minor and trace elements in mineral and biological samples from international intercomparison runs organised by IAEA Vienna, IAEA-MEL Monaco, 'pb-anal' Kosice, INCT Warszawa and IPNT Krakow is presented. Neutron irradiation was carried out at WWR-S reactor in Bucharest (short and long irradiation) during 1982-1997 and at TRIGA reactor in Pitesti (long irradiation) during the later period. The following type of materials were analysed: soils, marine sediments, uranium phosphate ore, water sludge, copper flue dust, whey powder, yeast, cereal flour (rye and wheat), marine animal tissue (mussel, garfish and tuna fish), as well as vegetal tissue (seaweed, cabbage, spinach, alfalfa, algae, tea leaves and herbs). The following elements could be, in general, determined: Ag, As, Au, Ba, Br, Ca, Ce, Co, Cr, Cs, Eu, Fe, Hf, Hg, K, La, Lu, Mo, Na, Nd, Ni, Rb, Sb, Sc, Se, Sm, Sr, Ta, Tb, Th, U, W, Yb and Zn of long-lived radionuclides, as well as Al, Ca, Cl, Cu, Mg, Mn, and Ti of short-lived radionuclides. Data obtained in our laboratory for various matrix samples presented and compared with the intercomparison certified values. The intercomparison exercises offer to the participating laboratories the opportunity to test the accuracy of their analytical methods as well as to acquire valuable Reference Materials/ standards for future analytical applications. (authors)

  20. Reference materials and interlaboratory comparison for actinide analysis

    Energy Technology Data Exchange (ETDEWEB)

    Hanssens, Alain; Viallesoubranne, Carole; Roche, Claude; Liozon, Gerard [Commissariat a l' Energie Atomique, Marcoule: BP 17171, 30207 Bagnols sur Ceze (France)

    2008-07-01

    Measurement quality is crucial for the safety of nuclear facilities and is a primary requirement for fissile material monitoring and accountancy. CETAMA (Cea Committee for the establishment of analysis methods), in collaboration with Cea and AREVA laboratories, fabricates certified reference materials and organizes interlaboratory comparison programs for plutonium and uranium assay in solution. A new plutonium metal measurement standard (MP3) is currently being prepared by Cea and is a subject of cooperative work in view of its certification and use by analysis laboratories. U and Pu interlaboratory comparisons are carried out at regular intervals on benchmark samples in coordination with working groups from French nuclear laboratories. These programs are supported by international cooperation. 'Chemical' methods (potentiometry, gravimetric analysis, etc.) generally provide the best accuracy. Coulometry is the benchmark technique for plutonium assay: its metrological qualities should be an incentive for wider use by laboratories performing precise control assays of plutonium as well as uranium. Gravimetric analysis provides excellent results for analysis of pure uranyl nitrate solutions. In view of its many advantages we encourage laboratories to employ this technique to assay pure U or Pu solutions. 'Physical' or 'physicochemical' methods are increasingly used, and their performance has improved. K-edge absorption spectrometry and isotope dilution mass spectrometry are capable of reaching measurement quality levels comparable to those of the best 'chemical' methods. (authors)

  1. Nuclear microprobe analysis of the standard reference materials

    International Nuclear Information System (INIS)

    Jaksic, M.; Fazinic, S.; Bogdanovic, I.; Tadic, T.

    2002-01-01

    Most of the presently existing Standard Reference Materials (SRM) for nuclear analytical methods are certified for the analyzed mass of the order of few hundred mg. Typical mass of sample which is analyzed by PIXE or XRF methods is very often below 1 mg. By the development of focused proton or x-ray beams, masses which can be typically analyzed go down to μg or even ng level. It is difficult to make biological or environmental SRMs which can give desired homogeneity at such low scale. However, use of fundamental parameter quantitative evaluation procedures (absolute method), minimize needs for SRMs. In PIXE and micro PIXE setup at our Institute, fundamental parameter approach is used. For exact calibration of the quantitative analysis procedure just one standard sample is needed. In our case glass standards which showed homogeneity down to micron scale were used. Of course, it is desirable to use SRMs for quality assurance, and therefore need for homogenous materials can be justified even for micro PIXE method. In this presentation, brief overview of PIXE setup calibration is given, along with some recent results of tests of several SRMs

  2. Topological materials discovery using electron filling constraints

    Science.gov (United States)

    Chen, Ru; Po, Hoi Chun; Neaton, Jeffrey B.; Vishwanath, Ashvin

    2018-01-01

    Nodal semimetals are classes of topological materials that have nodal-point or nodal-line Fermi surfaces, which give them novel transport and topological properties. Despite being highly sought after, there are currently very few experimental realizations, and identifying new materials candidates has mainly relied on exhaustive database searches. Here we show how recent studies on the interplay between electron filling and nonsymmorphic space-group symmetries can guide the search for filling-enforced nodal semimetals. We recast the previously derived constraints on the allowed band-insulator fillings in any space group into a new form, which enables effective screening of materials candidates based solely on their space group, electron count in the formula unit, and multiplicity of the formula unit. This criterion greatly reduces the computation load for discovering topological materials in a database of previously synthesized compounds. As a demonstration, we focus on a few selected nonsymmorphic space groups which are predicted to host filling-enforced Dirac semimetals. Of the more than 30,000 entires listed, our filling criterion alone eliminates 96% of the entries before they are passed on for further analysis. We discover a handful of candidates from this guided search; among them, the monoclinic crystal Ca2Pt2Ga is particularly promising.

  3. Electron beam melting of bearing materials

    Energy Technology Data Exchange (ETDEWEB)

    Goldschmied, G.; Schuler, A. (Technische Univ., Vienna (Austria). Inst. fuer Allgemeine Elektrotechnik); Elsinger, G.; Koroschetz, F. (MIBA Gleitlager AG, Laakirchen (Austria)); Tschegg, E.K. (Technische Univ., Vienna (Austria). Inst. fuer Angewandte und Technische Physik)

    1990-06-01

    This paper reports on a surface treatment method for the bearing materials AlSn6 which permits the use of this material without the overlay usually required. Microstructural refinement is achieved by means of a surface melting technique using an electron beam with successive rapid solidification. Extremely fine tin precipitates are formed in the melted surface layer which lead to significantly better tribological properties of the bearing material. Tests compared the tribological properties for AlSn6 bearings treated by the surface melting technique with those of untreated bearings. Whereas all untreated bearings failed by seizure after only 2 h of testing, 30% of the tested bearings which had been surface melted survived the entire testing program without damage.

  4. IAEA AQCS catalogue for reference materials and intercomparison exercises 1998/1999

    International Nuclear Information System (INIS)

    1999-01-01

    Fore more than thirty years the International Atomic Energy Agency (IAEA), through its Analytical Quality Control Services (AQCS) programme, has been assisting Member States' laboratories to maintain and improve the reliability of their analyses by organizing intercomparison exercises and by preparing and distributing biological, environmental and marine reference materials. The catalogue consists principally of two parts: The list of all available IAEA reference materials grouped into five categories: reference materials for radionuclides; reference materials for trace, minor and major elements, including oxides; reference materials for stable isotopes; reference materials for organic contaminants and methyl mercury containing materials. Lists of all available IAEA reference materials sorted by analytes. In addition information on recommended half-life data and suppliers of radioactive sources is provided. Planned intercomparisons are advertised and request forms for participation in intercomparisons are included. Forms for ordering reference materials, quality control spectra for gamma-spectrometry on diskettes and AQCS related publications are also provided

  5. Ab initio electronic stopping power in materials

    International Nuclear Information System (INIS)

    Shukri, Abdullah-Atef

    2015-01-01

    The average energy loss of an ion per unit path length when it is moving through the matter is named the stopping power. The knowledge of the stopping power is essential for a variety of contemporary applications which depend on the transport of ions in matter, especially ion beam analysis techniques and ion implantation. Most noticeably, the use of proton or heavier ion beams in radiotherapy requires the knowledge of the stopping power. Whereas experimental data are readily available for elemental solids, the data are much more scarce for compounds. The linear response dielectric formalism has been widely used in the past to study the electronic stopping power. In particular, the famous pioneering calculations due to Lindhard evaluate the electronic stopping power of a free electron gas. In this thesis, we develop a fully ab initio scheme based on linear response time-dependent density functional theory to predict the impact parameter averaged quantity named the random electronic stopping power (RESP) of materials without any empirical fitting. The purpose is to be capable of predicting the outcome of experiments without any knowledge of target material besides its crystallographic structure. Our developments have been done within the open source ab initio code named ABINIT, where two approximations are now available: the Random-Phase Approximation (RPA) and the Adiabatic Local Density Approximation (ALDA). Furthermore, a new method named 'extrapolation scheme' have been introduced to overcome the stringent convergence issues we have encountered. These convergence issues have prevented the previous studies in literature from offering a direct comparison to experiment. First of all, we demonstrate the importance of describing the realistic ab initio electronic structure by comparing with the historical Lindhard stopping power evaluation. Whereas the Lindhard stopping power provides a first order description that captures the general features of the

  6. Off the Shelf: Trends in the Purchase and Use of Electronic Reference Books

    Science.gov (United States)

    Korah, Abe; Cassidy, Erin; Elmore, Eric; Jerabek, Ann

    2009-01-01

    What is the future direction of reference books? What types of policies are libraries implementing regarding the purchase of electronic reference books? Are libraries still buying hard copy reference items when an electronic equivalent is available? This paper discusses a national survey of libraries regarding the purchase and use of electronic…

  7. Laboratory Reference Spectroscopy of Icy Satellite Candidate Surface Materials (Invited)

    Science.gov (United States)

    Dalton, J. B.; Jamieson, C. S.; Shirley, J. H.; Pitman, K. M.; Kariya, M.; Crandall, P.

    2013-12-01

    The bulk of our knowledge of icy satellite composition continues to be derived from ultraviolet, visible and infrared remote sensing observations. Interpretation of remote sensing observations relies on availability of laboratory reference spectra of candidate surface materials. These are compared directly to observations, or incorporated into models to generate synthetic spectra representing mixtures of the candidate materials. Spectral measurements for the study of icy satellites must be taken under appropriate conditions (cf. Dalton, 2010; also http://mos.seti.org/icyworldspectra.html for a database of compounds) of temperature (typically 50 to 150 K), pressure (from 10-9 to 10-3 Torr), viewing geometry, (i.e., reflectance), and optical depth (must manifest near infrared bands but avoid saturation in the mid-infrared fundamentals). The Planetary Ice Characterization Laboratory (PICL) is being developed at JPL to provide robust reference spectra for icy satellite surface materials. These include sulfate hydrates, hydrated and hydroxylated minerals, and both organic and inorganic volatile ices. Spectral measurements are performed using an Analytical Spectral Devices FR3 portable grating spectrometer from .35 to 2.5 microns, and a Thermo-Nicolet 6500 Fourier-Transform InfraRed (FTIR) spectrometer from 1.25 to 20 microns. These are interfaced with the Basic Extraterrestrial Environment Simulation Testbed (BEEST), a vacuum chamber capable of pressures below 10-9 Torr with a closed loop liquid helium cryostat with custom heating element capable of temperatures from 30-800 Kelvins. To generate optical constants (real and imaginary index of refraction) for use in nonlinear mixing models (i.e., Hapke, 1981 and Shkuratov, 1999), samples are ground and sieved to six different size fractions or deposited at varying rates to provide a range of grain sizes for optical constants calculations based on subtractive Kramers-Kronig combined with Hapke forward modeling (Dalton and

  8. Reference materials for molecular diagnostics: Current achievements and future strategies.

    Science.gov (United States)

    Jing, Rongrong; Wang, Huimin; Ju, Shaoqing; Cui, Ming

    2018-06-01

    Molecular diagnoses have become more widespread in many areas of laboratory medicine where qualitative or quantitative approaches are used to detect nucleic acids. The increasing number of assay methods and the targets for molecular diagnostics contribute to variability in the test results among clinical laboratories. Thus, reference materials (RMs) are required to enhance the comparability of results. This review focuses on the definition of RMs as well as the production and characteristics of higher order RMs from different organizations and their future strategies. We describe the recent progress in RMs, including the definition of RMs by the Joint Committee for Guides in Metrology, as well as the production and characteristics of higher order RMs by international official bodies. There is an urgent need for RMs in nucleic acid testing, especially higher order RMs. To advance the harmonization and standardization of clinical nucleic acid detection, cooperation between the above organizations is proposed and different approaches to higher order RMs development are also needed. Copyright © 2018 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  9. Plutonium working reference materials for the NDA PDP program

    International Nuclear Information System (INIS)

    Marshall, R.; Foley, M.; McCullough, L.; Vance, D.

    1995-01-01

    Sixty-three QC standards, termed Working Reference Materials (WRMs) are being fabricated at Los Alamos for the Non-destructive Waste Assay Performance Development Plan. The WRMs require Pu and Am distributed uniformly in a low density matrix. A silicone rubber matrix initially specified has been changed to a packed, diatomaceous earth (DE) matrix to facilitate Pu-DE uniformity and minimize gas generation and WRM pressurization. Uniformity and separation stability was demonstrated with iron powder-DE mixtures. To meet the rigorous quality objectives on the mass of Pu and Am for each WRM, a uniform, stable batch of PuO2 with relatively high Am-241 content was prepared by blending, calcining, and screening. Multiple sample analyses demonstrated the PuO2 to be highly uniform and established that tight Pu and Am assay and Pu isotopic analysis precision requirements were met. Test blends were prepared and tested to successfully demonstrate Pu uniformity, freedom from PuO2 clumping, and acceptable alpha-neutron generation rates. Blends of PuO2-DE were prepared individually for each WRM; all 63 blends have been prepared. After loading and packing the blends into zircalloy cylinders, the air atmosphere will be replaced with helium and end caps inserted and welded. Following decontamination and leak checking, the cylinders will be loaded into secondary zircalloy cylinders and sealed with welded end caps

  10. Reference material manufacture and certification for the AVNG

    Energy Technology Data Exchange (ETDEWEB)

    Hauck, Danielle K [Los Alamos National Laboratory; Thron, Jonathan [Los Alamos National Laboratory; MacArthur, Duncan W. [Los Alamos National Laboratory; Livke, Alexander [RFNC - VNIIEF; Bulatov, M [RFNC-VNIIEF; Kondratov, Sergey [RFNC-VNIIEF; Leplyavkina, M [RFNC-VNIIEF; Razinkov, Sergey [RFNC-VNIIEF; Sivachev, D [RFNC-VNIIEF; Tsybryaev, S [RFNC-VNIIEF; V' yushin, A [RFNC-VNIIEF

    2010-07-09

    Testing and demonstration of any radiation measurement system requires the use of appropriate radioactive sources. An attribute measurement system (A VNG) was developed and fabricated at the Russian Federal Nuclear Center, VNIIEF, Russia, under contract with LANL, USA. The A VNG detects neutron and gamma radiation signatures and compares the data analysis results with the specified threshold values for three unclassified attributes; plutonium is present or absent, plutonium mass is greater than or less than the specified threshold value and plutonium isotopic ratio 240Pu to 239Pu) is greater than or less then the threshold value. A set of reference materials (RMs) was specially manufactured for the A VNG with masses and isotopic ratios above and below the selected thresholds. The set of RMs was certified in compliance with the Russian metrological requirements. The RMs were used to debug and test the A VNG and to demonstrate the A VNG operation to an American delegation in June 2009. In this presentation, we will describe the various steps in the manufacture and certification of these RM sources.

  11. Reference material manufacture and certification for the AVNG

    Energy Technology Data Exchange (ETDEWEB)

    Hauck, Danielle K [Los Alamos National Laboratory; Mac Arthur, Duncan [Los Alamos National Laboratory; Thron, Jonathan L [Los Alamos National Laboratory; Livke, Alexander [VNIIEF; Kondratov, Sergey [VNIIEF; Razinkov, Sergey [VNIIEF

    2010-01-01

    Testing and demonstration of any radiation measurement system requires the use of appropriate radioactive sources. The AVNG implementation that we describe is an attribute measurement system built by RFNC - VNIIEF in Sarov, Russia. The AVNG detects neutron and gamma radiation signatures and displays the three unclassified attributes of 'plutonium presence,' 'plutonium mass > 2 kg,' and 'plutonium isotopic ratio ({sup 240}Pu to {sup 239}Pu) < 0.1.' The AVNG was tested using a number of reference material (RM) sources with masses and isotopic ratios above and below these thresholds. The AVNG was demonstrated in June 2009 using several of these sources in addition to detector calibration sources. Since the AVNG was designed to measure multi-kg plutonium sources, the RM was manufactured specifically for use with this system. In addition, the RM was used to test the thresholds in the AVNG, so the size and composition of each RM was certified prior to use. In this presentation, we will describe the various steps in the manufacture and certification of these RM sources.

  12. Reference material manufacture and certification for the AVNG

    International Nuclear Information System (INIS)

    2010-01-01

    Testing and demonstration of any radiation measurement system requires the use of appropriate radioactive sources. An attribute measurement system (A VNG) was developed and fabricated at the Russian Federal Nuclear Center, VNIIEF, Russia, under contract with LANL, USA. The A VNG detects neutron and gamma radiation signatures and compares the data analysis results with the specified threshold values for three unclassified attributes; plutonium is present or absent, plutonium mass is greater than or less than the specified threshold value and plutonium isotopic ratio 240 Pu to 239 Pu) is greater than or less then the threshold value. A set of reference materials (RMs) was specially manufactured for the A VNG with masses and isotopic ratios above and below the selected thresholds. The set of RMs was certified in compliance with the Russian metrological requirements. The RMs were used to debug and test the A VNG and to demonstrate the A VNG operation to an American delegation in June 2009. In this presentation, we will describe the various steps in the manufacture and certification of these RM sources.

  13. Reference Materials: Critical Importance to the Infant Formula Industry.

    Science.gov (United States)

    Wargo, Wayne F

    2017-09-01

    Infant formula is one of the most regulated foods in the world. It has advanced in complexity over the years as a result of numerous research innovations. To ensure product safety and quality, analytical technologies have also had to advance to keep pace. Given the rigorous performance demands expected of these methods and the ever-growing array of complex matrixes, there is the potential for gaps to exist in current Official MethodsSM and other recognized international methods for infant formula and adult nutritionals. Food safety concerns, particularly for infants, drive the need for extensive testing by manufacturers and regulators. The net effect is the potential for an increase in time- and resource-consuming regulatory disputes. In an effort to mitigate such costly activities, AOAC INTERNATIONAL, under the direction of the Infant Formula Council of America-a trade association of manufacturers and marketers of formulated nutritional products-agreed to establish voluntary consensus Standard Method Performance Requirements, and, ultimately, to identify and publish globally recognized, fit-for-purpose standard methods. To accomplish this task, nutritional reference materials (RMs), representing all major commercially available nutritional formulations, were (and continue to be) a critical necessity. In this paper, various types of RMs will be defined, followed by review and discussion of their importance to the infant formula industry.

  14. Physics of electronic materials principles and applications

    CERN Document Server

    Rammer, Jorgen

    2017-01-01

    Adopting a uniquely pedagogical approach, this comprehensive textbook on the quantum mechanics of semiconductor materials and devices focuses on the materials, components and devices themselves whilst incorporating a substantial amount of fundamental physics related to condensed matter theory and quantum mechanics. Written primarily for advanced undergraduate students in physics and engineering, this book can also be used as a supporting text for introductory quantum mechanics courses, and will be of interest to anyone interested in how electronic devices function at a fundamental level. Complete with numerous exercises, and with all the necessary mathematics and physics included in appendices, this book guides the reader seamlessly through the principles of quantum mechanics and the quantum theory of metals and semiconductors, before describing in detail how devices are exploited within electric circuits and in the hardware of computers, for example as amplifiers, switches and transistors. Includes nume...

  15. Transmission electron microscopy and diffractometry of materials

    CERN Document Server

    Fultz, Brent

    2001-01-01

    This book teaches graduate students the concepts of trans- mission electron microscopy (TEM) and x-ray diffractometry (XRD) that are important for the characterization of materi- als. It emphasizes themes common to both techniques, such as scattering from atoms and the formation and analysis of dif- fraction patterns. It also describes unique aspects of each technique, especially imaging and spectroscopy in the TEM. The textbook thoroughly develops both introductory and ad- vanced-level material, using over 400 accompanying illustra- tions. Problems are provided at the end of each chapter to reinforce key concepts. Simple citatioins of rules are avoi- ded as much as possible, and both practical and theoretical issues are explained in detail. The book can be used as both an introductory and advanced-level graduate text since sec- tions/chapters are sorted according to difficulty and grou- ped for use in quarter and semester courses on TEM and XRD.

  16. Artificial radioactivity in the environmental samples as IAEA reference materials

    International Nuclear Information System (INIS)

    Salagean, M.; Pantelica, A.

    1998-01-01

    . Uncontaminated by nuclear activities: IAEA-327, Podsolic soil collected in 1990 from the Moscow region and considered uncontaminated by radionuclides of the Chernobyl accident or by other nuclear activities. The results obtained by our laboratory are in good agreement with the certified IAEA data. Generally, the concentration of the artificial radionuclides in the investigated samples is higher than that expected from the influence of global fallout in the intercomparison materials distributed before Chernobyl accident. Concerning the nature of these investigated IAEA reference materials, very high values for the concentration levels of cesium radionuclides especially in IAEA-373 (grass) and IAEA-375 (soil) samples collected in the vicinity of Chernobyl Power Station after the nuclear accident in 1986 were found. High levels of radioactivities for the artificial radionuclides were also determined in the samples collected in the neighbourhood of the nuclear installations, especially in marine sediment (IAEA-135). It is of interest to point out the high concentration of cesium radionuclides in IAEA-300 sediment collected in 1992 in the Baltic Sea in comparison with the IAEA-306 sediment collected also in the Baltic Sea in 1986. It seems to be an increase of the Baltic Sea artificial radioactivity by accumulation in time. Marine sediment constitutes an important component of marine ecosystem since it represents the final sink for any releases of wastes into the sea. These certified radioactive materials are very useful to all laboratories engaged in the radioactive pollution investigations on environmental samples. (authors)

  17. Certification of a new biological reference material - Virginia Tobacco Leaves (CTA-VTL-2) and homogeneity study by NAA on this and other candidate reference materials

    International Nuclear Information System (INIS)

    Dybczynski, Rajmund; Polkowska-Motrenko, Halina; Samczynski, Zbigniew; Szopa, Zygmunt; Kulisa, Krzysztof; Wasek, Marek

    2002-01-01

    This report describes the laboratory's participation in the interlaboratory comparison run where the laboratory applied neutron activation analysis aimed at certification of the candidate reference material. Data evaluation and statistical treatment steps are discussed. The report also describes homogeneity study on the reference material and provides details of the analytical procedures

  18. Determination of cadmium, lead and zinc in a candidate reference materials using isotope dilution mass spectrometry

    International Nuclear Information System (INIS)

    Munoz, Luis; Gras, Nuri; Quejido, Alberto; Fernandez, Marta

    2001-01-01

    The growing demands placed on analytical laboratories to ensure the reliability of their results, due to the introduction of systems of quality and to the increasing use of metrology in chemical measurements has led most laboratories to validate their methodologies and to control them statistically. One of the techniques used most often for these purposes is based on the use of reference materials. The proper use of these materials means that laboratory results may be traced to the International System of Units, analytical methodologies can be validated, instruments calibrated and chemical measurements harmonized. One of the biggest challenges in developing reference materials is that of certifying their properties, a process that has been defined as assigning a concentration value that is as close as possible to the true value together with its uncertainty. Organizations that produce reference materials use several options for their certification process, and among these is the use of a primary method. Among the primary methods recognized by the International Office of Weights and Measures is the Isotope Dilution Mass Spectrometry technique. The Chilean Nuclear Energy Commission, through its Reference Materials Program, has prepared a reference material of clam tissue, which has been chemically defined by different analytical methodologies applied in different national and international laboratories. This work describes the methodology developed with the CIEMAT for determining the elements lead, cadmium and zinc in the clam tissue reference material using the primary technique of Isotope Dilution Mass Spectrometry. The calculation is described for obtaining the spike amounts to be added to the sample and the procedure is explained for carrying out the isotopic exchange. The isotopic relationships 204 Pb/ 205 Pb, 111 Cd/ 114 Cd and 66 Zn/ 67 Zn were determined in an atomic emission spectrometer with a plasma source with the following characteristics: plasma

  19. Development of сertified reference materials set for opened porosity of solid substances and materials (imitators

    Directory of Open Access Journals (Sweden)

    E. P. Sobina

    2016-01-01

    Full Text Available The article deals with data of research for development of certified reference materials set for opened porosity of solid substances and materials (imitators (OPTB SO UNIIM Set Certified Reference Materials GSO 10583-2015. The certified values of opened porosity of metal cylinders were established by the method of hydrostatic weighing before and after boring of holes in. The certified reference materials are intended for calibration and verification of measuring instruments of opened porosity, based on the Boyle - Mariotte's law.

  20. On the interpretation of micro-PIXE measurements on a prototype microstructured reference material

    International Nuclear Information System (INIS)

    Waetjen, Uwe; Barsony, Istvan; Grime, Geoff W.; Rajta, Istvan

    1999-01-01

    In order to determine the beam spot size and scanning properties of ion microbeam systems, a novel reference material has been developed, consisting of permalloy (81% Ni, 19% Fe) strip patterns on silicon substrate. Due to the choice of substrate and pattern materials, these samples exhibit a high elemental contrast suitable for analysis with X-ray detection and ion scattering techniques. The microlithographic production scheme is briefly described. A prototype chip of this material was investigated with PIXE and RBS analysis in a scanning nuclear microprobe. It proved to be extremely useful in the routine to focus the ion microbeam and to determine its spot size. Due to the microscopic structure of these samples, a geometric dependence of matrix effects in the production of Si X-rays from the substrate material could be shown. Even dead-time effects in the counting electronics, showing up as an apparent thickness gradient, could be observed. Besides its primary role in microbeam diagnostics, this reference material can serve an educational role in developing the analyst's ability to correctly identify and interpret such artefacts

  1. Sustainable Materials Management (SMM) Electronics Challenge

    Science.gov (United States)

    Learn how the SMM Electronics Challenge encourage electronic manufacturers to strive to send 100 percent of the used electronics they collect from the public and retailers to certified electronics refurbishers and recyclers.

  2. 2007 Electronic Reference Services In Nigerian Law Libraries.

    African Journals Online (AJOL)

    ezra

    interaction or interviewing techniques. The ... change. Abid, (2002), observed it is now common to find reference resources such as dictionaries .... Com,) Live Helper http:www. Wehelper. ..... sources, resources and strategies for legal research ...

  3. Radiation effects on and dose enhancement of electronic materials

    International Nuclear Information System (INIS)

    Srour, J.R.; Long, D.M.

    1984-01-01

    This book describes radiation effects on and dose enhancement factors for electronic materials. Alteration of the electrical properties of solid-state devices and integrated circuits by impinging radiation is well-known. Such changes may cause an electronic subsystem to fail, thus there is currently great interest in devising methods for avoiding radiation-induced degradation. The development of radiation-hardened devices and circuits is an exciting approach to solving this problem for many applications, since it could minimize the need for shielding or other system hardening techniques. Part 1 describes the basic mechanisms of radiation effects on electronic materials, devices, and integrated circuits. Radiation effects in bulk silicon and in silicon devices are treated. Ionizing radiation effects in silicon dioxide films and silicon MOS devices are discussed. Single event phenomena are considered. Key literature references and a bibliography are provided. Part II provides tabulations of dose enhancement factors for electronic devices in x-ray and gamma-ray environments. The data are applicable to a wide range of semiconductor devices and selected types of capacitors. Radiation environments discussed find application in system design and in radiation test facilities

  4. Review of neutron activation analysis in the standardization and study of reference materials, including its application to radionuclide reference materials

    International Nuclear Information System (INIS)

    Byrne, A.R.

    1993-01-01

    Neutron activation analysis (NAA) plays a very important role in the certification of reference materials (RMs) and their characterization, including homogeneity testing. The features of the method are briefly reviewed, particularly aspects relating to its completely independent nuclear basis, its virtual freedom from blank problems, and its capacity for self-verification. This last aspect, arising from the essentially isotopic character of NAA, can be exploited by using different nuclear reactions and induced nuclides, and the possibility of employing two modes, one instrumental (nondestructive), the other radiochemical (destructive). This enables the derivation of essentially independent analytical information and the unique capacity of NAA for selfvalidation. The application of NAA to quantify natural or man-made radionuclides such as uranium, thorium, 237 Np, 129 I and 230 Th is discussed, including its advantages over conventional radiometric methods and its usefulness in providing independent data for nuclides where other confirmatory analyses are impossible, or are only recently becoming available through newer 'atom counting' techniques. Certain additional, prospective uses of NAA in the study of RMs and potential RMs are mentioned, including transmutation reactions, creation of endogenously radiolabelled matrices for production and study of RMs (such as dissolution and leaching tests, use as incorporated radiotracers for chemical recovery correction), and the possibility of molecular activation analysis for specification. (orig.)

  5. Survey of reference materials for trace elements, nuclides and organic microcontaminants

    International Nuclear Information System (INIS)

    Parr, R.M.; Stone, S.F.; Bel-Amakeletch, T.; Zeisler, R.

    1998-01-01

    The International Atomic Energy Agency (IAEA), in co-operation with the United Nations Environment Programme (UNEP), has recently prepared a survey on internationally available analytical reference materials for trace elements, nuclides and organic contaminants in biological, environmental and related matrices. The purpose is to help analysts to select reference materials for quality assurance that match as closely as possible, with respect to matrix type and concentrations of the measurands of interest, the ''real'' samples that are to be measured. The present version of the survey, which is available in the form of two cost-free printed volumes [1], contains over 10,000 certified and information values in 650 reference materials from 27 different producers. The 455 measurands listed include trace elements, major and minor elements, organic contaminants, organometallic compounds, radionuclides and stable isotopes. Currently, the database from which the survey has been produced is being modified and extended so as to make the data available in electronic form via the Internet. (orig.)

  6. Quantitative Scanning Transmission Electron Microscopy of Electronic and Nanostructured Materials

    Science.gov (United States)

    Yankovich, Andrew B.

    Electronic and nanostructured materials have been investigated using advanced scanning transmission electron microscopy (STEM) techniques. The first topic is the microstructure of Ga and Sb-doped ZnO. Ga-doped ZnO is a candidate transparent conducting oxide material. The microstructure of GZO thin films grown by MBE under different growth conditions and different substrates were examined using various electron microscopy (EM) techniques. The microstructure, prevalent defects, and polarity in these films strongly depend on the growth conditions and substrate. Sb-doped ZnO nanowires have been shown to be the first route to stable p-type ZnO. Using Z-contrast STEM, I have showed that an unusual microstructure of Sb-decorated head-to-head inversion domain boundaries and internal voids contain all the Sb in the nanowires and cause the p-type conduction. InGaN thin films and InGaN / GaN quantum wells (QW) for light emitting diodes are the second topic. Low-dose Z-contrast STEM, PACBED, and EDS on InGaN QW LED structures grown by MOCVD show no evidence for nanoscale composition variations, contradicting previous reports. In addition, a new extended defect in GaN and InGaN was discovered. The defect consists of a faceted pyramid-shaped void that produces a threading dislocation along the [0001] growth direction, and is likely caused by carbon contamination during growth. Non-rigid registration (NRR) and high-precision STEM of nanoparticles is the final topic. NRR is a new image processing technique that corrects distortions arising from the serial nature of STEM acquisition that previously limited the precision of locating atomic columns and counting the number of atoms in images. NRR was used to demonstrate sub-picometer precision in STEM images of single crystal Si and GaN, the best achieved in EM. NRR was used to measure the atomic surface structure of Pt nanoacatalysts and Au nanoparticles, which revealed new bond length variation phenomenon of surface atoms. In

  7. Reference Materials in LIS Instruction: A Delphi Study

    Science.gov (United States)

    Rabina, Debbie

    2013-01-01

    This paper presents the results of a Delphi study conducted over a two-month period in 2011. The purpose of the study was to identify reference sources that should be covered in basic reference courses taught in LIS programs in the United States. The Delphi method was selected for its appropriateness in soliciting expert opinions and assessing the…

  8. Secondary Electron Emission Materials for Transmission Dynodes in Novel Photomultipliers: A Review

    Directory of Open Access Journals (Sweden)

    Shu Xia Tao

    2016-12-01

    Full Text Available Secondary electron emission materials are reviewed with the aim of providing guidelines for the future development of novel transmission dynodes. Materials with reflection secondary electron yield higher than three and transmission secondary electron yield higher than one are tabulated for easy reference. Generations of transmission dynodes are listed in the order of the invention time with a special focus on the most recent atomic-layer-deposition synthesized transmission dynodes. Based on the knowledge gained from the survey of secondary election emission materials with high secondary electron yield, an outlook of possible improvements upon the state-of-the-art transmission dynodes is provided.

  9. Epitaxial Graphene: A New Material for Electronics

    Science.gov (United States)

    de Heer, Walt A.

    2007-10-01

    Graphene multilayers are grown epitaxially on single crystal silicon carbide. This system is composed of several graphene layers of which the first layer is electron doped due to the built-in electric field and the other layers are essentially undoped. Unlike graphite the charge carriers show Dirac particle properties (i.e. an anomalous Berry's phase, weak anti-localization and square root field dependence of the Landau level energies). Epitaxial graphene shows quasi-ballistic transport and long coherence lengths; properties that may persists above cryogenic temperatures. Paradoxically, in contrast to exfoliated graphene, the quantum Hall effect is not observed in high mobility epitaxial graphene. It appears that the effect is suppressed due to absence of localized states in the bulk of the material. Epitaxial graphene can be patterned using standard lithography methods and characterized using a wide array of techniques. These favorable features indicate that interconnected room temperature ballistic devices may be feasible for low dissipation high-speed nano-electronics.

  10. Lipid Bilayer Formation on Organic Electronic Materials

    KAUST Repository

    Zhang, Yi

    2018-04-23

    The lipid bilayer is the elemental structure of cell membrane, forming a stable barrier between the interior and exterior of the cell while hosting membrane proteins that enable selective transport of biologically important compounds and cellular recognition. Monitoring the quality and function of lipid bilayers is thus essential and can be performed using electrically active substrates that allow for transduction of signals. Such a promising electronic transducer material is the conducting polymer poly(3,4-ethylenedioxythiophene) doped with poly(styrene sulfonate) (PEDOT:PSS) which has provided a plethora of novel bio transducing architectures. The challenge is however in assembling a bilayer on the conducting polymer surface, which is defect-free and has high mobility. Herein, we investigate the fusion of zwitterionic vesicles on a variety of PEDOT:PSS films, but also on an electron transporting, negatively charged organic semiconductor, in order to understand the surface properties that trigger vesicle fusion. The PEDOT:PSS films are prepared from dispersions containing different concentrations of ethylene glycol included as a formulation additive, which gives a handle to modulate surface physicochemical properties without a compromise on the chemical composition. The strong correlation between the polarity of the surface, the fusion of vesicles and the mobility of the resulting bilayer aides extracting design principles for the development of future conducting polymers that will enable the formation of lipid bilayers.

  11. Nuclear measurements and reference materials annual progress report, january - december 1988

    International Nuclear Information System (INIS)

    1989-01-01

    The 1988 progress report of the Central Bureau for Nuclear Measurements (CBNM) is presented. The major changes in the role and orientation of the Joint Research Center, of which CBNM is an institute, are included. The main tasks of CBNM, which involve the program on Nuclear Measurements and Reference Materials, are given. Technical activities concerning the GELINA electron beam and Van de Graaff accelerators are reported. The study of transition radiation at linear electron accelerators, and the development of isotope dilution mass spectrometry, for trace analysis and isotope abundance measurements in iron and gallium, are summarized. The scientific and technical support to the commission, work for third parties, and contribution to conferences are presented

  12. Electronic journals and scholarly communication: a citation and reference study

    Directory of Open Access Journals (Sweden)

    Stephen P. Harter

    1996-01-01

    Full Text Available The journal is fundamental to formal scholarly communication. This research reports highlights and preliminary findings from an empirical study of scholarly electronic journals. The purpose of the research is to assess the impact of electronic journals (e-journals on scholarly communication, by measuring the extent to which they are being cited in the literature, both print and electronic. The intent is to provide a snapshot of the impact e-journals were having on scholarly communication at a given point in time, roughly the end of 1995. This study provides one measure of that impact, specifically on the formal, as opposed to informal, communication process. The study also examines the forms in which scholars cite e-journals, the accuracy and completeness of citations to e-journals, and practical difficulties faced by scholars and researchers who wish to retrieve e-journals through the networks.

  13. Advances in superconducting materials and electronics technologies

    International Nuclear Information System (INIS)

    Palmer, D.N.

    1990-01-01

    Technological barriers blocking the early implementation of ceramic oxide high critical temperature [Tc] and LHe Nb based superconductors are slowly being dismantled. Spearheading these advances are mechanical engineers with diverse specialties and creative interests. As the technology expands, most engineers have recognized the importance of inter-disciplinary cooperation. Cooperation between mechanical engineers and material and system engineers is of particular importance. Recently, several problems previously though to be insurmountable, has been successfully resolved. These accomplishment were aided by interaction with other scientists and practitioners, working in the superconductor research and industrial communities, struggling with similar systems and materials problems. Papers published here and presented at the 1990 ASME Winter Annual Meeting held in Dallas, Texas 25-30 November 1990 can be used as a bellwether to gauge the progress in the development of both ceramic oxide and low temperature Nb superconducting device and system technologies. Topics are focused into two areas: mechanical behavior of high temperature superconductors and thermal and mechanical problems in superconducting electronics

  14. Ordered materials for organic electronics and photonics.

    Science.gov (United States)

    O'Neill, Mary; Kelly, Stephen M

    2011-02-01

    We present a critical review of semiconducting/light emitting, liquid crystalline materials and their use in electronic and photonic devices such as transistors, photovoltaics, OLEDs and lasers. We report that annealing from the mesophase improves the order and packing of organic semiconductors to produce state-of-the-art transistors. We discuss theoretical models which predict how charge transport and light emission is affected by the liquid crystalline phase. Organic photovoltaics and OLEDs require optimization of both charge transport and optical properties and we identify the various trade-offs involved for ordered materials. We report the crosslinking of reactive mesogens to give pixellated full-colour OLEDs and distributed bi-layer photovoltaics. We show how the molecular organization inherent to the mesophase can control the polarization of light-emitting devices and the gain in organic, thin-film lasers and can also provide distributed feedback in chiral nematic mirrorless lasers. We update progress on the surface alignment of liquid crystalline semiconductors to obtain monodomain devices without defects or devices with spatially varying properties. Finally the significance of all of these developments is assessed. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  15. Oxide bipolar electronics: materials, devices and circuits

    International Nuclear Information System (INIS)

    Grundmann, Marius; Klüpfel, Fabian; Karsthof, Robert; Schlupp, Peter; Schein, Friedrich-Leonhard; Splith, Daniel; Yang, Chang; Bitter, Sofie; Von Wenckstern, Holger

    2016-01-01

    We present the history of, and the latest progress in, the field of bipolar oxide thin film devices. As such we consider primarily pn-junctions in which at least one of the materials is a metal oxide semiconductor. A wide range of n-type and p-type oxides has been explored for the formation of such bipolar diodes. Since most oxide semiconductors are unipolar, challenges and opportunities exist with regard to the formation of heterojunction diodes and band lineups. Recently, various approaches have led to devices with high rectification, namely p-type ZnCo 2 O 4 and NiO on n-type ZnO and amorphous zinc-tin-oxide. Subsequent bipolar devices and applications such as photodetectors, solar cells, junction field-effect transistors and integrated circuits like inverters and ring oscillators are discussed. The tremendous progress shows that bipolar oxide electronics has evolved from the exploration of various materials and heterostructures to the demonstration of functioning integrated circuits. Therefore a viable, facile and high performance technology is ready for further exploitation and performance optimization. (topical review)

  16. Electron Beam Welding of Thick Copper Material

    Energy Technology Data Exchange (ETDEWEB)

    Broemssen, Bernt von [IVF Industriforskning och utveckling AB, Stockholm (Sweden)

    2002-08-01

    The purpose of this study was to review the two variants of the Electron Beam Welding (EBW) processes developed (or used) by 1- SKB, Sweden with assistance from TWI, England and 2 - POSIVA, Finland with assistance from Outokumpu, Finland. The aim was also to explain the principle properties of the EBW method: how it works, the parameters controlling the welding result but also giving rise to benefits, and differences between the EBW variants. The main conclusions are that both SKB and POSIVA will within a few years succeed to qualify their respective EBW method for welding of copper canisters. The Reduced Pressure EBW that SKB use today seems to be very promising in order to avoid root defects. If POSIVA does not succeed to avoid root defects with the high vacuum method and the beam oscillation technique it should be possible for POSIVA to incorporate the Reduced Pressure technique albeit with significant changes to the EBW equipment. POSIVA has possibly an advantage over SKB with the beam oscillation technique used, which gives an extra degree of freedom to affect the weld quality. The beam oscillation could be of importance for closing of the keyhole. Before EBW of lids, the material certification showing the alloy content (specifying min and max impurity percentages) and the mechanical properties should be checked. The welded material needs also to be tested for mechanical properties. If possible the weld should have a toughness level equal to that of the unwelded parent material. Specifically some conclusions are reported regarding the SKB equipment. Suggestions for further development are also given in the conclusion chapter.

  17. Electron Beam Welding of Thick Copper Material

    International Nuclear Information System (INIS)

    Broemssen, Bernt von

    2002-08-01

    The purpose of this study was to review the two variants of the Electron Beam Welding (EBW) processes developed (or used) by 1- SKB, Sweden with assistance from TWI, England and 2 - POSIVA, Finland with assistance from Outokumpu, Finland. The aim was also to explain the principle properties of the EBW method: how it works, the parameters controlling the welding result but also giving rise to benefits, and differences between the EBW variants. The main conclusions are that both SKB and POSIVA will within a few years succeed to qualify their respective EBW method for welding of copper canisters. The Reduced Pressure EBW that SKB use today seems to be very promising in order to avoid root defects. If POSIVA does not succeed to avoid root defects with the high vacuum method and the beam oscillation technique it should be possible for POSIVA to incorporate the Reduced Pressure technique albeit with significant changes to the EBW equipment. POSIVA has possibly an advantage over SKB with the beam oscillation technique used, which gives an extra degree of freedom to affect the weld quality. The beam oscillation could be of importance for closing of the keyhole. Before EBW of lids, the material certification showing the alloy content (specifying min and max impurity percentages) and the mechanical properties should be checked. The welded material needs also to be tested for mechanical properties. If possible the weld should have a toughness level equal to that of the unwelded parent material. Specifically some conclusions are reported regarding the SKB equipment. Suggestions for further development are also given in the conclusion chapter

  18. REFERENCE MATERIALS SYSTEM OF SCIENTIFIC METHODICAL CENTRE OF STATE SERVICE OF REFERENCE MATERIALS FOR COMPOSITION AND PROPERTIES OF SUBSTANCES AND MATERIALS URAL RESEARCH INSTITUTE FOR METROLOGY

    Directory of Open Access Journals (Sweden)

    E. V. Osinseva

    2015-01-01

    Full Text Available Since 1960s UNIIM performs research in the field of needs in reference materials of composition and properties of substances and materials (RM as well as develops it. During the research UNIIM has developed 757 types of RMs for metrological measurement assurance of factors of composition and properties of substance and materials for test laboratories of chemical, pharmaceutical, fuel, food industry, agriculture, metallurgy and ecological monitoring laboratories. List ofRMs enlarges thanks to development of UNIIM standards and transmission measurement facility from State standards of units. Taking into account the actual requirements in the field of measurements, the UNIIM's key destination is to assure the accuracy and the metrological traceability of measurements. The present-day system of RMs to be developed in UNIIM includes RMs of composition of inorganic and organic compounds and their solutions, fuels, stable isotopic materials, water, grounds, food products, biomaterials, nanomaterials, metals, alloys and other materials offerrous and non-ferrous industry, RMs of properties (thermodynamic, magnetic, physical-chemical, technical of substances and materials. The present article considers history of RMs list development which were created by UNIIM and the strategy of this direction.

  19. A soil sampling reference site: The challenge in defining reference material for sampling

    International Nuclear Information System (INIS)

    De Zorzi, Paolo; Barbizzi, Sabrina; Belli, Maria; Fajgelj, Ales; Jacimovic, Radojko; Jeran, Zvonka; Sansone, Umberto; Perk, Marcel van der

    2008-01-01

    In the frame of the international SOILSAMP project, funded and coordinated by the Italian Environmental Protection Agency, an agricultural area was established as a reference site suitable for performing soil sampling inter-comparison exercises. The reference site was characterized for trace element content in soil, in terms of the spatial and temporal variability of their mass fraction. Considering that the behaviour of long-lived radionuclides in soil can be expected to be similar to that of some stable trace elements and that the distribution of these trace elements in soil can simulate the distribution of radionuclides, the reference site characterised in term of trace elements, can be also used to compare the soil sampling strategies developed for radionuclide investigations

  20. A soil sampling reference site: The challenge in defining reference material for sampling

    Energy Technology Data Exchange (ETDEWEB)

    De Zorzi, Paolo [Agenzia per la Protezione dell' Ambiente e per i Servizi Tecnici (APAT), Servizio Metrologia Ambientale, Via di Castel Romano, Rome 100-00128 (Italy)], E-mail: paolo.dezorzi@apat.it; Barbizzi, Sabrina; Belli, Maria [Agenzia per la Protezione dell' Ambiente e per i Servizi Tecnici (APAT), Servizio Metrologia Ambientale, Via di Castel Romano, Rome 100-00128 (Italy); Fajgelj, Ales [International Atomic Energy Agency (IAEA), Agency' s Laboratories Seibersdorf, Vienna A-1400 (Austria); Jacimovic, Radojko; Jeran, Zvonka; Sansone, Umberto [Jozef Stefan Institute, Jamova 39, Ljubljana 1000 (Slovenia); Perk, Marcel van der [Department of Physical Geography, Utrecht University, P.O. Box 80115, TC Utrecht 3508 (Netherlands)

    2008-11-15

    In the frame of the international SOILSAMP project, funded and coordinated by the Italian Environmental Protection Agency, an agricultural area was established as a reference site suitable for performing soil sampling inter-comparison exercises. The reference site was characterized for trace element content in soil, in terms of the spatial and temporal variability of their mass fraction. Considering that the behaviour of long-lived radionuclides in soil can be expected to be similar to that of some stable trace elements and that the distribution of these trace elements in soil can simulate the distribution of radionuclides, the reference site characterised in term of trace elements, can be also used to compare the soil sampling strategies developed for radionuclide investigations.

  1. A soil sampling reference site: the challenge in defining reference material for sampling.

    Science.gov (United States)

    de Zorzi, Paolo; Barbizzi, Sabrina; Belli, Maria; Fajgelj, Ales; Jacimovic, Radojko; Jeran, Zvonka; Sansone, Umberto; van der Perk, Marcel

    2008-11-01

    In the frame of the international SOILSAMP project, funded and coordinated by the Italian Environmental Protection Agency, an agricultural area was established as a reference site suitable for performing soil sampling inter-comparison exercises. The reference site was characterized for trace element content in soil, in terms of the spatial and temporal variability of their mass fraction. Considering that the behaviour of long-lived radionuclides in soil can be expected to be similar to that of some stable trace elements and that the distribution of these trace elements in soil can simulate the distribution of radionuclides, the reference site characterised in term of trace elements, can be also used to compare the soil sampling strategies developed for radionuclide investigations.

  2. Production of candidate natural matrix reference materials for micro-analytical techniques

    International Nuclear Information System (INIS)

    Zeisler, R.; Fajgelj, A.; Zeiller, E.

    2002-01-01

    Homogeneity is considered to be the most vital prerequisite for a certified reference material (CRM); more stringent requirements exist for the analysis of small subsamples. Many of the natural matrix CRMs are prepared from bulk samples by grinding and milling them to a certain particle size, which is expected to provide a more homogenous material; however recommended sample sizes for biological and environmental reference materials are found to be more than 100 mg. Since the milling of materials is costly and has some drawbacks, natural materials that already occur as small particles such as air particulate matter, certain sediments, and cellular biological materials may form the basis of the required reference materials. The nature of these materials, i.e. naturally occurring particles, may provide ideal model reference material. We describe here the production of the materials and preliminary tests, the evaluation for the micro-analytical techniques

  3. 10 CFR 431.303 - Materials incorporated by reference.

    Science.gov (United States)

    2010-01-01

    ... this material at NARA, call 202-741-6030 or go to http://www.archives.gov/federal_register/code_of... through Friday, except Federal holidays, or go to: http://www1.eere.energy.gov/buildings/appliance... and Materials, 100 Barr Harbor Drive, West Conshohocken, PA 19428-2959, (610) 832-9500, or http://www...

  4. Challenges in the size analysis of a silica nanoparticle mixture as candidate certified reference material

    International Nuclear Information System (INIS)

    Kestens, Vikram; Roebben, Gert; Herrmann, Jan; Jämting, Åsa; Coleman, Victoria; Minelli, Caterina; Clifford, Charles; Temmerman, Pieter-Jan De; Mast, Jan; Junjie, Liu; Babick, Frank; Cölfen, Helmut; Emons, Hendrik

    2016-01-01

    A new certified reference material for quality control of nanoparticle size analysis methods has been developed and produced by the Institute for Reference Materials and Measurements of the European Commission’s Joint Research Centre. The material, ERM-FD102, consists of an aqueous suspension of a mixture of silica nanoparticle populations of distinct particle size and origin. The characterisation relied on an interlaboratory comparison study in which 30 laboratories of demonstrated competence participated with a variety of techniques for particle size analysis. After scrutinising the received datasets, certified and indicative values for different method-defined equivalent diameters that are specific for dynamic light scattering (DLS), centrifugal liquid sedimentation (CLS), scanning and transmission electron microscopy (SEM and TEM), atomic force microscopy (AFM), particle tracking analysis (PTA) and asymmetrical-flow field-flow fractionation (AF4) were assigned. The value assignment was a particular challenge because metrological concepts were not always interpreted uniformly across all participating laboratories. This paper presents the main elements and results of the ERM-FD102 characterisation study and discusses in particular the key issues of measurand definition and the estimation of measurement uncertainty.

  5. Challenges in the size analysis of a silica nanoparticle mixture as candidate certified reference material

    Energy Technology Data Exchange (ETDEWEB)

    Kestens, Vikram, E-mail: vikram.kestens@ec.europa.eu; Roebben, Gert [Joint Research Centre (JRC), European Commission, Institute for Reference Materials and Measurements (IRMM) (Belgium); Herrmann, Jan; Jämting, Åsa; Coleman, Victoria [National Measurement Institute Australia, Nanometrology Section (Australia); Minelli, Caterina; Clifford, Charles [National Physical Laboratory, Analytical Science Division (United Kingdom); Temmerman, Pieter-Jan De; Mast, Jan [Service Electron Microscopy, Veterinary and Agrochemical Research Centre (CODA-CERVA) (Belgium); Junjie, Liu [National Institute of Metrology, Division of Nanoscale Measurement and Advanced Materials (China); Babick, Frank [Technische Universität Dresden, Institut für Verfahrens- und Umwelttechnik (Germany); Cölfen, Helmut [University of Konstanz, Physical Chemistry, Department of Chemistry (Germany); Emons, Hendrik [Joint Research Centre (JRC), European Commission, Institute for Reference Materials and Measurements (IRMM) (Belgium)

    2016-06-15

    A new certified reference material for quality control of nanoparticle size analysis methods has been developed and produced by the Institute for Reference Materials and Measurements of the European Commission’s Joint Research Centre. The material, ERM-FD102, consists of an aqueous suspension of a mixture of silica nanoparticle populations of distinct particle size and origin. The characterisation relied on an interlaboratory comparison study in which 30 laboratories of demonstrated competence participated with a variety of techniques for particle size analysis. After scrutinising the received datasets, certified and indicative values for different method-defined equivalent diameters that are specific for dynamic light scattering (DLS), centrifugal liquid sedimentation (CLS), scanning and transmission electron microscopy (SEM and TEM), atomic force microscopy (AFM), particle tracking analysis (PTA) and asymmetrical-flow field-flow fractionation (AF4) were assigned. The value assignment was a particular challenge because metrological concepts were not always interpreted uniformly across all participating laboratories. This paper presents the main elements and results of the ERM-FD102 characterisation study and discusses in particular the key issues of measurand definition and the estimation of measurement uncertainty.

  6. An in-house usage assessment of print reference materials in a ...

    African Journals Online (AJOL)

    The study investigated the utilization of print reference materials in a Nigerian hybrid medical school library, factors influencing utilization or under utilization, and if utilization commensurate with the library's prospect on the use of these materials. During the period of study, it was assumed that all reference materials pulled ...

  7. The WSPC Reference on Organic Electronics: Organic Semiconductors

    KAUST Repository

    Bredas, Jean-Luc

    2015-05-12

    In this chapter, we provide a basic theoretical perspective on charge-carrier transport in organic semiconductors, with a focus on organic molecular crystals. We introduce the microscopic parameters relevant to the intrinsic charge-transport properties of these materials and describe some of the common quantum-chemical approaches used for their evaluation. We also discuss the nature of the possible charge-transport mechanisms in organic molecular crystals.

  8. An inter-laboratory comparison of Si isotope reference materials

    NARCIS (Netherlands)

    Reynolds, B.C.; Aggarwal, J.; André, L.; Baxter, B.; Beucher, C.; Brzezinski, M.A.; Engström, E.; Georg, R.B.; Land, M.; Leng, M.J.; Opfergelt, S.; Rodushkin, I.; Sloane, H.J.; Van den Boorn, S.H.J.M.; Vroon, P.Z.; Cardinal, D.

    2007-01-01

    Three Si isotope materials have been used for an inter-laboratory comparison exercise to ensure reproducibility between international laboratories investigating natural Si isotope variations using a variety of chemical preparation methods and mass spectrometric techniques. These proposed standard

  9. Recommended reference materials for realization of physicochemical properties pressure-volume-temperature relationships

    CERN Document Server

    Herington, E F G

    1977-01-01

    Recommended Reference Materials for Realization of Physicochemical Properties presents recommendations of reference materials for use in measurements involving physicochemical properties, namely, vapor pressure; liquid-vapor critical temperature and critical pressure; orthobaric volumes of liquid and vapor; pressure-volume-temperature properties of the unsaturated vapor or gas; and pressure-volume-temperature properties of the compressed liquid. This monograph focuses on reference materials for vapor pressures at temperatures up to 770 K, as well as critical temperatures and critical pressures

  10. Sustainable Materials Management (SMM) Electronics Challenge Data

    Data.gov (United States)

    U.S. Environmental Protection Agency — On September 22, 2012, EPA launched the SMM Electronics Challenge. The Challenge encourages electronics manufacturers, brand owners and retailers to strive to send...

  11. Dissolution chemistry and biocompatibility of single-crystalline silicon nanomembranes and associated materials for transient electronics.

    Science.gov (United States)

    Hwang, Suk-Won; Park, Gayoung; Edwards, Chris; Corbin, Elise A; Kang, Seung-Kyun; Cheng, Huanyu; Song, Jun-Kyul; Kim, Jae-Hwan; Yu, Sooyoun; Ng, Joanne; Lee, Jung Eun; Kim, Jiyoung; Yee, Cassian; Bhaduri, Basanta; Su, Yewang; Omennetto, Fiorenzo G; Huang, Yonggang; Bashir, Rashid; Goddard, Lynford; Popescu, Gabriel; Lee, Kyung-Mi; Rogers, John A

    2014-06-24

    Single-crystalline silicon nanomembranes (Si NMs) represent a critically important class of material for high-performance forms of electronics that are capable of complete, controlled dissolution when immersed in water and/or biofluids, sometimes referred to as a type of "transient" electronics. The results reported here include the kinetics of hydrolysis of Si NMs in biofluids and various aqueous solutions through a range of relevant pH values, ionic concentrations and temperatures, and dependence on dopant types and concentrations. In vitro and in vivo investigations of Si NMs and other transient electronic materials demonstrate biocompatibility and bioresorption, thereby suggesting potential for envisioned applications in active, biodegradable electronic implants.

  12. Reference materials and their role in quality assurance in environmental monitoring

    International Nuclear Information System (INIS)

    Cortes, Eduardo

    2002-01-01

    The importance of a good and routine quality control procedure for the analyses of environmental samples is presented. The use of Reference Materials as one simple procedure for validating analytical methodologies and determining the accuracy of analytical data is emphasized. The quality of the reference materials is also discussed as well as their selection and correct use. The convenience of preparing 'in-house' reference materials is discussed and attention is called to relevant aspects to be considered. An example of the preparation of a reference material is presented and some aspects of the procedure are discussed. (author)

  13. Transmission electron microscope studies of extraterrestrial materials

    Science.gov (United States)

    Keller, Lindsay P.

    1995-01-01

    Transmission Electron Microscopy, X-Ray spectrometry and electron-energy-loss spectroscopy are used to analyse carbon in interplanetary dust particles. Optical micrographs are shown depicting cross sections of the dust particles embedded in sulphur. Selected-area electron diffraction patterns are shown. Transmission Electron Microscope specimens of lunar soil were prepared using two methods: ion-milling and ultramicrotomy. A combination of high resolution TEM imaging and electron diffraction is used to characterize the opaque assemblages. The opaque assemblages analyzed in this study are dominated by ilmenite with lesser rutile and spinel exsolutions, and traces of Fe metal.

  14. Observation of defects evolution in electronic materials

    Science.gov (United States)

    Jang, Jung Hun

    Advanced characterization techniques have been used to obtain a better understanding of the microstructure of electronic materials. The structural evolution, especially defects, has been investigated during the film growth and post-growth processes. Obtaining the relation between the defect evolution and growth/post-growth parameters is very important to obtain highly crystalline films. In this work, the growth and post-growth related defects in GaN, ZnO, strained-Si/SiGe films have been studied using several advanced characterization techniques. First of all, the growth of related defects in GaN and p-type ZnO films have been studied. The effect of growth parameters, such as growth temperature, gas flow rate, dopants used during the deposition, on the crystalline quality of the GaN and ZnO layers was investigated by high resolution X-ray diffraction (HRXRD) and transmission electron microscopy (TEM). In GaN films, it was found that the edge and mixed type threading dislocations were the dominant defects so that the only relevant figure of merit (FOM) for the crystalline quality should be the FWHM value of o-RC of the surface perpendicular plane which could be determined by a grazing incidence x-ray diffraction (GIXD) technique as shown in this work. The understanding of the relationship between the defect evolution and growth parameters allowed for the growth of high crystalline GaN films. For ZnO films, it was found that the degree of texture and crystalline quality of P-doped ZnO films decreased with increasing the phosphorus atomic percent. In addition, the result from the x-ray diffraction line profile analysis showed that the 0.5 at % P-doped ZnO film showed much higher microstrain than the 1.0 at % P-doped ZnO film, which indicated that the phosphorus atoms were segregated with increasing P atomic percentage. Finally, post-growth related defects in strained-Si/SiGe films were investigated. Postgrowth processes used in this work included high temperature N2

  15. Standard Reference Development of nuclear material for Tensile and Hardness Test Properties

    International Nuclear Information System (INIS)

    Choo, Y. S.; Kim, D. S.; Yoo, B. O.; Ahn, S. B.; Baik, S. J.; Chun, Y. B.; Kim, K. H.; Hong, K. P.; Ryu, W. S.

    2007-12-01

    Standard reference is a official approved data such a coefficient of physics, approved material properties, and etc., which should be analyzed and evaluated by scientific method to acquire official approval for accuracy and credibility of measured data and information. So it could be used broadly and continuously by various fields of nation and society. It is classified to effective standard reference, verified standard reference, and certified standard reference. There are sixteen fields in designated standard references such a physical chemistry field, material field, metal field, and the others. The standard reference of neutron irradiated nuclear structural material is classified to metal field. This report summarized the whole processes about data collection, data production, data evaluation and the suggestion of details evaluation technical standard for tensile and hardness properties, which were achieved by carry out the project 'nuclear material standard reference development' as a result

  16. Standard Reference Development of nuclear material for Tensile and Hardness Test Properties

    Energy Technology Data Exchange (ETDEWEB)

    Choo, Y. S.; Kim, D. S.; Yoo, B. O.; Ahn, S. B.; Baik, S. J.; Chun, Y. B.; Kim, K. H.; Hong, K. P.; Ryu, W. S

    2007-12-15

    Standard reference is a official approved data such a coefficient of physics, approved material properties, and etc., which should be analyzed and evaluated by scientific method to acquire official approval for accuracy and credibility of measured data and information. So it could be used broadly and continuously by various fields of nation and society. It is classified to effective standard reference, verified standard reference, and certified standard reference. There are sixteen fields in designated standard references such a physical chemistry field, material field, metal field, and the others. The standard reference of neutron irradiated nuclear structural material is classified to metal field. This report summarized the whole processes about data collection, data production, data evaluation and the suggestion of details evaluation technical standard for tensile and hardness properties, which were achieved by carry out the project 'nuclear material standard reference development' as a result.

  17. Alternative buffer material. Status of the ongoing laboratory investigation of reference materials and test package 1

    International Nuclear Information System (INIS)

    Svensson, Daniel; Dueck, Ann; Nilsson, Ulf; Olsson, Siv; Sanden, Torbjoern; Lydmark, Sara; Jaegerwall, Sara; Pedersen, Karsten; Hansen, Staffan

    2011-07-01

    Bentonite clay is part of the Swedish KBS-3 design of final repositories for high level radioactive waste. Wyoming bentonite with the commercial name MX-80 (American Colloid Co) has long been the reference for buffer material in the KBS-3 concept. Extending the knowledge base of alternative buffer materials will make it possible to optimize regarding safety, availability and cost. For this reason the field experiment Alternative Buffer Material (ABM) was started at Aespoe Hard Rock Laboratory during 2006. The experiment includes three medium-scale test packages, each consisting of a central steel tube with heaters, and a buffer of compacted clay. Eleven different clays were chosen for the buffers to examine effects of smectite content, interlayer cations and overall iron content. Also bentonite pellets with and without additional quartz are being tested. The buffer in package 1 had been subjected to wetting by formation water and heating for more than two years (at 130 deg C for ∼ 1 year) when it was retrieved and analyzed. The main purposes of the project were to characterise the clays with respect to hydro-mechanical properties, mineralogy and chemical composition and to identify any differences in behaviour or long term stability. The diversity of clays and the heater of steel also make the experiment suitable for studies of iron-bentonite interactions. This report concerns the work accomplished up to now and is not to be treated as any final report of the project

  18. Alternative buffer material. Status of the ongoing laboratory investigation of reference materials and test package 1

    Energy Technology Data Exchange (ETDEWEB)

    Svensson, Daniel [Swedish Nuclear Fuel and Waste Management Co., Stockholm (Sweden); Dueck, Ann; Nilsson, Ulf; Olsson, Siv; Sanden, Torbjoern [Clay Technology AB, Lund (Sweden); Lydmark, Sara; Jaegerwall, Sara; Pedersen, Karsten [Microbial Analytics Sweden AB, Moelnlycke (Sweden); Hansen, Staffan [LTH Lund Univ., Lund (Sweden)

    2011-07-15

    Bentonite clay is part of the Swedish KBS-3 design of final repositories for high level radioactive waste. Wyoming bentonite with the commercial name MX-80 (American Colloid Co) has long been the reference for buffer material in the KBS-3 concept. Extending the knowledge base of alternative buffer materials will make it possible to optimize regarding safety, availability and cost. For this reason the field experiment Alternative Buffer Material (ABM) was started at Aespoe Hard Rock Laboratory during 2006. The experiment includes three medium-scale test packages, each consisting of a central steel tube with heaters, and a buffer of compacted clay. Eleven different clays were chosen for the buffers to examine effects of smectite content, interlayer cations and overall iron content. Also bentonite pellets with and without additional quartz are being tested. The buffer in package 1 had been subjected to wetting by formation water and heating for more than two years (at 130 deg C for {approx} 1 year) when it was retrieved and analyzed. The main purposes of the project were to characterise the clays with respect to hydro-mechanical properties, mineralogy and chemical composition and to identify any differences in behaviour or long term stability. The diversity of clays and the heater of steel also make the experiment suitable for studies of iron-bentonite interactions. This report concerns the work accomplished up to now and is not to be treated as any final report of the project.

  19. Advanced materials for thermal management of electronic packaging

    CERN Document Server

    Tong, Xingcun Colin

    2011-01-01

    The need for advanced thermal management materials in electronic packaging has been widely recognized as thermal challenges become barriers to the electronic industry's ability to provide continued improvements in device and system performance. With increased performance requirements for smaller, more capable, and more efficient electronic power devices, systems ranging from active electronically scanned radar arrays to web servers all require components that can dissipate heat efficiently. This requires that the materials have high capability of dissipating heat and maintaining compatibility

  20. 10 CFR 431.323 - Materials incorporated by reference.

    Science.gov (United States)

    2010-01-01

    ... National Standard for Lamp Ballasts—Ballasts for High-Intensity Discharge Lamps—Methods of Measurement... AND INDUSTRIAL EQUIPMENT Metal Halide Lamp Ballasts and Fixtures Test Procedures § 431.323 Materials... National Standard for electric lamps: Single-Ended Metal Halide Lamps, approved May 5, 2004, IBR approved...

  1. The preparation of four biological reference materials for QUASIMEME

    NARCIS (Netherlands)

    Leeuwen, van S.P.J.; Pieters, H.; Boer, de J.

    2004-01-01

    Four biological materials have been prepared for use in QUASIMEME interlaboratory studies including a shrimp sample for metal analysis (QM01-1) and two mussel (QO01-3 and QO02-2) and one mackerel sample (QO02-1) for organic contaminant analysis.

  2. 10 CFR 431.293 - Materials incorporated by reference.

    Science.gov (United States)

    2010-01-01

    ....293 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY PROGRAM FOR CERTAIN COMMERCIAL.../code_of_federal_regulations/ibr_locations.html. This material is also available for inspection at U.S. Department of Energy, Office of Energy Efficiency and Renewable Energy, Building Technologies Program, 6th...

  3. 10 CFR 431.63 - Materials incorporated by reference.

    Science.gov (United States)

    2010-01-01

    ... Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY PROGRAM FOR CERTAIN COMMERCIAL AND..._of_federal_regulations/ibr_locations.html. Also, this material is available for inspection at U.S. Department of Energy, Office of Energy Efficiency and Renewable Energy, Building Technologies Program, 6th...

  4. 10 CFR 431.85 - Materials incorporated by reference.

    Science.gov (United States)

    2010-01-01

    ... Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY PROGRAM FOR CERTAIN COMMERCIAL AND..._locations.html. Also, this material is available for inspection at U.S. Department of Energy, Office of Energy Efficiency and Renewable Energy, Building Technologies Program, 6th Floor, 950 L'Enfant Plaza, SW...

  5. Alpha damage in non-reference waste form matrix materials

    International Nuclear Information System (INIS)

    Burnay, S.G.

    1987-05-01

    Although bitumen is the matrix material currently used for European α-bearing intermediate level waste streams, polymer and polymer-modified cement matrices could have advantages over bitumen for such wastes. Two organic matrix systems have been studied - an epoxide resin, and an epoxide modified cement. Alpha irradiations were carried out by incorporating 241 Am at approx. 0.9 Ci/l. Comparisons have been made with unirradiated material and with materials which had been γ-irradiated to the same dose as the α-irradiated samples. Measurements were made of dimensional changes, mechanical properties and the leaching behaviour of 241 Am and 137 Cs. A limited amount of swelling (< 3%) was observed in α-irradiated epoxide resin; none was observed in the epoxide modified cement. Gamma irradiation to 300 kGy has no significant effect on the mechanical properties of either system. However, alpha irradiation to the same dose produced significant changes in flexural strength, an increase for the polymer and a decrease for the polymer-cement. Leaching in these systems was found to be a diffusion-controlled process; alpha irradiation to approx. 250 kGy has little effect on the leaching behaviour of either system. (author)

  6. Recent developments in the field of environmental reference materials at the JRC Ispra.

    Science.gov (United States)

    Muntau, H

    2001-06-01

    The production of reference materials for environmental analysis started in the Joint Research Centre at Ispra/Italy in 1972 with the objective of later certification by the BCR, but for obvious budget reasons only a fraction of the total production achieved at Ispra ever reached certification level, although all materials were produced according to the severe quality requirements requested for certified reference materials. Therefore, the materials not destinated to certification are in growing demand as inter-laboratory test materials and as laboratory reference materials, for internal quality control, e.g., by control charts. The history of reference material production within the Joint Research Centre is briefly reviewed and the latest additions described. New developments such as micro-scale reference materials intended for analytical methods requiring sample intakes at milligram or sub-milligram level and therefor not finding supply on the reference material market, and "wet" environmental reference materials, which meet more precisely the "real-world" environmental analysis conditions, are presented and the state-of-the-art discussed.

  7. The Diverse Ecology of Electronic Materials

    NARCIS (Netherlands)

    Mody, Cyrus C.M.; Teissier, Pierre; Mody, Cyrus C. M.; Tiggelen, Brigitte van

    2017-01-01

    Silicon has been the dominant material in microelectronics for a half century. Other materials, however, have subsidiary roles in microelectronics manufacturing. A few materials have even been promoted as replacements for silicon. Yet because of silicon’s dominance, none of these alternatives has

  8. Survey of currently available reference materials for use in connection with the determination of trace elements in biological materials

    International Nuclear Information System (INIS)

    Parr, R.M.

    1983-09-01

    Elemental analysis of biological materials is at present the subject of intensive study by many different research groups throughout the world, in view of the importance of these trace elements in health and medical diagnosis. IAEA and other organizations are now making a variety of suitable reference materials available for use in connection with the determination of trace elements in biological materials. To help analysts in making a selection from among these various materials, the present report provides a brief survey of data for all such biological reference materials known to the author. These data are compiled by the author from January 1982 to June 1983

  9. Multicenter evaluation of the commutability of a potential reference material for harmonization of enzyme activities

    NARCIS (Netherlands)

    Scharnhorst, V.; Apperloo, J.J.; Baadenhuijsen, H.; Vader, H.L.

    2014-01-01

    Standardization of laboratory results allows for the use of common reference intervals and can be achieved via calibration of field methods with secondary reference materials. These harmonization materials should be commutable, i.e., they produce identical numerical results independent of assay

  10. Neutron activation analysis of trace elements in IAEA reference materials

    International Nuclear Information System (INIS)

    Cheema, M.N.; Hasany, S.M.; Hanif, I.; Chaudhry, M.S.; Qureshi, I.H.

    1978-09-01

    Analytical Chemistry Group of Nuclear Chemistry Division at PINSTECH has been participating in IAEA Intercomparison programme of analytical quality control since 1972. So far fifteen samples of a variety of materials received from the Agency have been analyzed for different minor and trace elements. Mostly destructive and non-destructive neutron activation analysis techniques have been used for elemental analysis. In this report the description of the samples and the experimental procedures employed have been mentioned. The results of elemental analysis have been reported and compared with IAEA values which are based on the average computed from the results of different participating laboratories. (authors)

  11. Preparation and certification of the Polish reference material 'Oriental Tobacco Leaves' (CTA-OTL-1) for inorganic trace analysis

    International Nuclear Information System (INIS)

    Dybczynski, R.; Polkowska-Motrenko, H.; Samczynski, Z.; Szopa, Z.

    1996-01-01

    A new Polish certified reference material 'Oriental Tobacco Leaves' (CTA-OTL-1) for inorganic trace analysis was prepared. Fresh tobacco leaves of variety 'Oriental' were dried, ground and sieved. All precautions were taken to avoid contamination of material with metals. The next step was homogenization. Preliminary homogeneity checking consisted in determining of Ca, Fe and K content by X-ray fluorescence. Final homogeneity testing was performed by neutron activation analysis determining Co, Cr, Fe and Rb. To assure long-term stability, the whole lot of material was sterilized by electron beam radiation. Certification of the candidate reference material was done on the basis of world-wide interlaboratory comparisons exercise in which 61 laboratories, using various analytical methods participated. (author). 30 refs, 12 tabs, 21 figs

  12. Preparation and certification of the Polish reference material `Oriental Tobacco Leaves` (CTA-OTL-1) for inorganic trace analysis

    Energy Technology Data Exchange (ETDEWEB)

    Dybczynski, R.; Polkowska-Motrenko, H.; Samczynski, Z.; Szopa, Z. [Institute of Nuclear Chemistry and Technology, Warsaw (Poland)

    1996-12-31

    A new Polish certified reference material `Oriental Tobacco Leaves` (CTA-OTL-1) for inorganic trace analysis was prepared. Fresh tobacco leaves of variety `Oriental` were dried, ground and sieved. All precautions were taken to avoid contamination of material with metals. The next step was homogenization. Preliminary homogeneity checking consisted in determining of Ca, Fe and K content by X-ray fluorescence. Final homogeneity testing was performed by neutron activation analysis determining Co, Cr, Fe and Rb. To assure long-term stability, the whole lot of material was sterilized by electron beam radiation. Certification of the candidate reference material was done on the basis of world-wide interlaboratory comparisons exercise in which 61 laboratories, using various analytical methods participated. (author). 30 refs, 12 tabs, 21 figs.

  13. Laser Lights or Dim Bulbs? Evaluating Reference Librarians' Use of Electronic Sources.

    Science.gov (United States)

    Welch, Jeanie M.

    1999-01-01

    Discusses the evaluation of academic library reference librarians' effectiveness in providing services to patrons using electronic sources based on experiences at the University of North Carolina at Charlotte. Topics include core technical competencies for subject specialists and reference desk service; the Internet; and methods of evaluation.…

  14. Mechanism based evaluation of materials behavior and reference curves

    International Nuclear Information System (INIS)

    Toerroenen, K.; Saario, T.; Wallin, K.; Forsten, J.

    1984-01-01

    The safety assessment of nuclear pressure vessels and piping requires a quantitative estimation of defect growth by stable and unstable manner during service. This estimation is essential for determining whether the defect detected during inspection should be repaired or whether the size of the defect even after its expected growth is small enough to leave the integrity of the vessel unaffected. The most important stable defect growth mechanism is that of environmentally assisted cyclic crack growth. Recent results indicate that it is markedly affected by sulfur content and/or manganese sulfide morphology and distribution. This implies that an essential improvement in component safety has been gained by currently applied steelmaking practices, which result in extra low sulfur content, generally below 0.01 wt%, and in round shape and small size of inclusions, through, e.g., calcium treatment, hence considerably reducing the effect of environment on crack growth rate. This further implies that the ASME Section XI reference curves for environmentally accelerated cyclic crack growth are conservative for steels produced by current steelmaking practices. (orig./WL)

  15. Standard and reference materials for environmental science. Part 1. Technical memo

    Energy Technology Data Exchange (ETDEWEB)

    Cantillo, A.Y.

    1995-11-01

    This is the fourth edition of the catalog of reference materials suited for use in environmental science, originally compiled in 1986 for NOAA, IOC, and UNEP. The catalog lists more than 1200 reference materials from 28 producers and contains information about their proper use, sources, availability, and analyte concentrations. Indices are included for elements, isotopes, and organic compounds, as are cross references to CAS registry numbers, alternate names, and chemical structures of selected organic compounds.

  16. Standard and reference materials for environmental science. Part 2. Technical memo

    Energy Technology Data Exchange (ETDEWEB)

    Cantillo, A.Y.

    1995-11-01

    This is the fourth edition of the catalog of reference materials suited for use in environmental science, originally compiled in 1986 for NOAA, IOC, and UNEP. The catalog lists more than 1200 reference materials from 28 producers and contains information about their proper use, sources, availability, and analyte concentrations. Indices are included for elements, isotopes, and organic compounds, as are cross references to CAS registry numbers, alternate names, and chemical structures of selected organic compounds.

  17. Instrumental neutron activation analysis of marine sediment in-house reference material

    International Nuclear Information System (INIS)

    Nazaratul Ashifa Abdullah Salim; Mohd Suhaimi Hamzah; Mohd Suhaimi Elias; Siong, W.B.; Shamsiah Abdul Rahman; Azian Hashim; Shakirah Abdul Shukor

    2013-01-01

    Reference materials play an important role in demonstrating the quality and reliability of analytical data. The advantage of using in-house reference materials is that they provide a relatively cheap option as compared to using commercially available certified reference material (CRM) and can closely resemble the laboratory routine test sample. A marine sediment sample was designed as an in-house reference material, in the framework of quality assurance and control (QA/QC) program of the Neutron Activation Analysis (NAA) Laboratory at Nuclear Malaysia. The NAA technique was solely used for the homogeneity test of the marine sediment sample. The CRM of IAEA- Soil 7 and IAEA- SL1 (Lake Sediment) were applied in the analysis as compatible matrix based reference materials for QA purposes. (Author)

  18. Noncovalent Interactions in Organic Electronic Materials

    KAUST Repository

    Ravva, Mahesh Kumar; Risko, Chad; Bredas, Jean-Luc

    2017-01-01

    In this chapter, we provide an overview of how noncovalent interactions, determined by the chemical structure of π-conjugated molecules and polymers, govern essential aspects of the electronic, optical, and mechanical characteristics of organic

  19. Conjugated material self-assembly : towards supramolecular electronics

    NARCIS (Netherlands)

    Leclère, P.E.L.G.; Surin, M.; Cavallini, M.; Jonkheijm, P.; Henze, O.; Schenning, A.P.H.J.; Biscarini, F.; Grimsdale, A.C.; Feast, W.J.; Meijer, E.W.; Müllen, K.; Brédas, J.L.; Lazzaroni, R.

    2004-01-01

    Properties of organic electronic materials in solid-state are determined as individual molecules and molecular assembly. It is essential to optimize conjugated materials to control performance of molecular assembly that constitute electronic devices such as light-emitting diodes and solar cells, and

  20. Amorphous electron-accepting materials for organic optoelectronics

    NARCIS (Netherlands)

    Ganesan, P.

    2007-01-01

    The importance of organic materials for use in electronic devices such as OLEDs, OFETs and photovoltaic cells has increased significantly over the past decade. Organic materials have been attractive candidates for such electronic devices because of their compatibility with high-throughput,

  1. Material machining with pseudo-spark electron beams

    International Nuclear Information System (INIS)

    Benker, W.; Christiansen, J.; Frank, K.; Gundel, H.; Redel, T.; Stetter, M.

    1989-01-01

    The authors give a brief description of the production of pseudo-spark (low pressure gas discharge) electron beams. They illustrate the use of these electron beams for machining not only conducting, semiconducting and insulating materials, but also thin layers of such materials as high temperature superconducting ceramics

  2. Induced radioactivity evaluation for reference materials by European scientific cooperation

    International Nuclear Information System (INIS)

    Ventura, A.; Reffo, G.; Avrigeanu, V.; Antonov, A.N.; Grypeos, M.; Trkov, A.

    1997-01-01

    The global objective of this research is to apply the latest theoretical achievements for calculation of nuclear quantities on the request lists of the current EC projects related to activation (European Activation File) and fusion (European Fusion File, Joint Evaluation File and Fusion Evaluated Nuclear Data Library). The main goal has concerned the (n,p) and (n,α) reaction cross sections, of first importance for prediction of radiation damage in fusion reactor stainless steel. The required development of adequate activation computer codes and data libraries are expected to provide improvement of the following types of nuclear data: - threshold and capture reactions leading to long-lived radionuclides; - other neutron-induced reactions producing the most critical activities in elements ranging from boron to bismuth; - charged-particle emission spectra of neutron-induced reactions and charged-particle induced reactions needed to treat the important sequential (x,n) reactions; - detailed error estimates of critical nuclear data, in order to specify the uncertainty levels of current predictions for radiological properties of potential low-activation materials

  3. Production and Evaluation of 236gNp and Reference Materials for Naturally Occurring Radioactive Materials

    Science.gov (United States)

    Larijani, Cyrus Kouroush

    This thesis is based on the development of a radiochemical separation scheme capable of separating both 236gNp and 236Pu from a uranium target of natural isotopic composition ( 1 g uranium) and 200 MBq of fission decay products. The isobaric distribution of fission residues produced following the bombardment of a natural uranium target with a beam of 25 MeV protons has been evaluated. Decay analysis of thirteen isobarically distinct fission residues were carried out using high-resolution gamma-ray spectrometry at the UK National Physical Laboratory. Stoichiometric abundances were calculated via the determination of absolute activity concentrations associated with the longest-lived members of each isobaric chain. This technique was validated by computational modelling of likely sequential decay processes through an isobaric decay chain. The results were largely in agreement with previously published values for neutron bombardments on natural uranium at energies of 14 MeV. Higher relative yields of products with mass numbers A 110-130 were found, consistent with the increasing yield of these radionuclides as the bombarding energy is increased. Using literature values for the production cross-section for fusion of protons with uranium targets, it is estimated that an upper limit of approximately 250 Bq of activity from the 236Np ground state was produced in this experiment. Using a radiochemical separation scheme, Np and Pu fractions were separated from the produced fission decay products, with analyses of the target-based final reaction products made using Inductively Couple Plasma Mass Spectrometry (ICP-MS) and high-resolution alpha and gamma-ray spectrometry. In a separate research theme, reliable measurement of Naturally Occurring Radioactive Materials is of significance in order to comply with environmental regulations and for radiological protection purposes. The thesis describes the standardisation of three reference materials, namely Sand, Tuff and TiO2 which

  4. Electron microscopy of some exotic materials

    International Nuclear Information System (INIS)

    Mitchell, T.E.

    1998-01-01

    Just about every material has been looked at under the microscope, either out of pure inquisitiveness or the need to relate the microstructure to its properties. Some of these materials are mundane, like steels or glass or polyethylene; others are so-called advanced, such as intermetallics, silicon nitride or zirconia; yet others might be called exotic whether they be martian rocks, high temperature superconductors, fullerenes, diamonds, or the latest thin film device. Many exotic materials are important in Los Alamos, not only weapons materials such as actinides, tritium and explosives, but also civilian materials for energy applications. Here the author will report briefly on plutonium and uranium, on rhenium disilicide, and on Cu-Nb nanolayered composites

  5. Electron emission from materials at low excitation energies

    International Nuclear Information System (INIS)

    Urma, N.; Kijek, M.; Millar, J.J.

    1996-01-01

    Full text: An experimental system has been designed and developed with the purpose of measuring the total electron emission yield from materials at low energy excitation. In the first instance the reliability of the system was checked by measuring the total electron emission yield for a well defined surface (aluminium 99.45%). The obtained data was in the expected range given by the literature, and consequently the system will be used further for measuring the total electron yield for a range of materials with interest in the instrumentation industry. We intend to measure the total electron emission yield under electron bombardment as a function of incident electron energy up to 1200 eV, angle of incidence, state of the surface and environment to which the surface has been exposed. Dependence of emission on total electron irradiated dose is also of interest. For many practical application of the 'Secondary Electron Emission', the total electron yield is desired to be as large as possible. The above phenomenon has practical applicability in electron multiplier tube and Scanning electron microscopy - when by means of the variation of the yield of the emitted electrons one may produce visible images of small sample areas. The electron multiplier tube, is a device which utilises the above effect to detect and amplify both single particles and low currents streams of charged particles. The majority of electron tubes use electrons with low energy, hundreds of eV. Not a lot has been published in the literature about this regime and also about the emission when the impinging electrons have small energy, up to 1 KeV. The information obtained from the experimental measurements concerning the total electron emission yield is used to asses the investigated materials as a potential electron emitting surfaces or dynodes in an electron multiplier tube

  6. Approved reference and testing materials for use in Nuclear Waste Management Research and Development Programs

    International Nuclear Information System (INIS)

    Mellinger, G.B.; Daniel, J.L.

    1984-12-01

    This document, addressed to members of the waste management research and development community summarizes reference and testing materials available from the Nuclear Waste Materials Characterization Center (MCC). These materials are furnished under the MCC's charter to distribute reference materials essential for quantitative evaluation of nuclear waste package materials under development in the US. Reference materials with known behavior in various standard waste management related tests are needed to ensure that individual testing programs are correctly performing those tests. Approved testing materials are provided to assist the projects in assembling materials data base of defensible accuracy and precision. This is the second issue of this publication. Eight new Approved Testing Materials are listed, and Spent Fuel is included as a separate section of Standard Materials because of its increasing importance as a potential repository storage form. A summary of current characterization information is provided for each material listed. Future issues will provide updates of the characterization status of the materials presented in this issue, and information about new standard materials as they are acquired. 7 references, 1 figure, 19 tables

  7. 76 FR 65212 - Henkel Corporation, Currently Known as Henkel Electronic Materials, LLC, Electronic Adhesives...

    Science.gov (United States)

    2011-10-20

    ..., Currently Known as Henkel Electronic Materials, LLC, Electronic Adhesives Division, Including On-Site Leased..., Electronic Adhesives Division, including on-site leased workers from Aerotek Professional Services, Billerica..., Electronic Adhesives Division had their wages reported under a separate unemployment insurance (UI) tax...

  8. Scanning electron microscopy of semiconductor materials

    International Nuclear Information System (INIS)

    Bresse, J.F.; Dupuy, M.

    1978-01-01

    The use of scanning electron microscopy in semiconductors opens up a large field of use. The operating modes lending themselves to the study of semiconductors are the induced current, cathodoluminescence and the use of the potential contrast which can also be applied very effectively to the study of the devices (planar in particular). However, a thorough knowledge of the mechanisms of the penetration of electrons, generation and recombination of generated carriers in a semiconductor is necessary in order to attain a better understanding of the operating modes peculiar to semiconductors [fr

  9. Reference material IAEA 413: Major, minor and trace elements in algae

    International Nuclear Information System (INIS)

    2010-01-01

    Reference materials are a basic requirement for any sort of quantitative chemical and radiochemical analysis. Laboratories need them for calibration and quality control throughout their analytical work. The IAEA started to produce reference materials in the early 1960s to meet the needs of the analytical laboratories in its Member States that required reference materials for quality control of their measurements. The initial efforts were focused on the preparation of environmental reference materials containing anthropogenic radionuclides for use by those laboratories employing nuclear analytical techniques. These reference materials were characterized for their radionuclide content through interlaboratory comparison involving a core group of some 10 to 20 specialist laboratories. The success of these early exercises led the IAEA to extend its activities to encompass both terrestrial and marine reference materials containing primordial radionuclides and trace elements. Today, the IAEA has more than 90 reference materials and maintains a customer base of about 5000 members from more than 85 Member States. Within the frame of IAEA activities in production and certification of RM, this report describes the certification of the IAEA 413: Major, minor and trace elements in algae. Details are given on methodologies and data evaluation

  10. Three New Offset {delta}{sup 11}B Isotope Reference Materials for Environmental Boron Isotope Studies

    Energy Technology Data Exchange (ETDEWEB)

    Rosner, M. [BAM Federal Institute for Materials Research and Testing, Berlin (Germany); IsoAnalysis UG, Berlin (Germany); Vogl, J. [BAM Federal Institute for Materials Research and Testing, Berlin (Germany)

    2013-07-15

    The isotopic composition of boron is a well established tool in various areas of science and industry. Boron isotope compositions are typically reported as {delta}{sup 11}B values which indicate the isotopic difference of a sample relative to the isotope reference material NIST SRM 951. A significant drawback of all of the available boron isotope reference materials is that none of them covers a natural boron isotope composition apart from NIST SRM 951. To fill this gap of required {delta}{sup 11}B reference materials three new solution boric acid reference materials were produced, which cover 60 per mille of the natural boron isotope variation (-20 to 40 per mille {delta}{sup 11}B) of about 100 per mille . The new reference materials are certified for their {delta}{sup 11}B values and are commercially available through European Reference Materials (http://www.erm-crm.org). The newly produced and certified boron isotope reference materials will allow straightforward method validation and quality control of boron isotope data. (author)

  11. IAEA programme of natural matrix reference materials for the determination of radionuclides

    International Nuclear Information System (INIS)

    Strachnov, V.; Valkovic, V.; LaRosa, J.; Dekner, R.; Zeisler, R.

    1993-01-01

    The International Atomic Energy Agency has been providing analytical quality control services (AQCS) to its Member States since the 1960's. The AQCS programme distributes reference materials (RMs), organizes intercomparison runs, and provides training courses for quality assurance in chemical analysis and radioactivity measurements of food, biological, environmental and marine materials. This paper focusses on those aspects of the subject dealing with reference materials and intercomparison runs for the determination of radionuclides. Nineteen natural matrix reference materials are available for the determination of radionuclides. Twelve new intercomparison and reference materials are in preparation or under consideration. The radionuclides of interest include: K-40, Mn-54, Co-60, Sr-90, Tc-99, Ru-106, Ba-133, Cs-134, Cs-137, Pb-210, Ra-226, Th-228, Th-232, Pu-238, Pu-239 + 240. (orig.)

  12. Determination of trace elements in electronic materials by NAA

    International Nuclear Information System (INIS)

    Kobayashi, Kenji

    1986-01-01

    Trace amounts of elements in electronic materials were determined by instrumental neutron activation analysis (INAA), re-activation analysis and substoichiometric radioactivation analysis using gamma-ray spectrometry. Ten elements (Cr, Cu, Fe, Zn, Co, Eu, Ir, Sb, Sc, Tb) in gallium arsenide single crystal were determined by INAA and substoichiometric radioactivation analysis. Trace level of chromium (10 13 atoms/cm 3 ) and zinc (10 14 atoms/cm 3 ) in gallium arsenide single crystal were determined by INAA. The chromium concentrations in horizontal Bridgmangrown semi-insulating gallium arsenide ingot were ranged from 1.2 x 10 16 atoms/cm 3 at seed end to 3.5 x 10 16 atoms/cm 3 at tail end. The trace determinations of iron (10 14 atoms/cm 3 ) and copper (10 14 atoms/cm 3 ) in silicon, gallium arsenide and indium phoshide single crystals were carried out by substoichiometric radioactivation analysis. The reactivation analysis for the multielement determination of indium phosphide single crystal was carried out and nineteen elements were determined simultaneously by gamma-ray spectrometry. Eleven elements (Ag, As, Br, Co, Cr, Fe, K, Mn, Sb, Sc, Zn) in four NIES standard reference materials (Pond Sediment, Chlorella, Mussel and Tea Leaves) and seven elements (Co, Cr, Eu, Fe, Sc, Tb, Yb) in two NBS glasses (SRM-615 and SRM-613) were determined by INAA and substoichiometric radioactivation analysis and the analytical results obtained by the methods were in good agreement with certified values by NIES and NBS. (author)

  13. Two spruce shoot candidate reference materials from the German environmental specimen bank

    International Nuclear Information System (INIS)

    Backhaus, F.; Bagschik, U.; Burow, M.; Froning, M.; Mohl, C.; Ostapczuk, P.; Rossbach, M.; Schladot, J.D.; Stoeppler, M.; Waidmann, E.; Byrne, A.R.; Zeisler, R.

    1994-01-01

    Two new materials are introduced that might serve as useful aids for the harmonisation of analytical results. Spruce shoots, cryogenically homogenized and characterized for 50 elements from two sampling sites of the German Environmental Specimen Bank (ESB) are presented as possible third generation reference materials that might also act as calibrating materials in speciation analysis. (author)

  14. Universal electronic-cigarette test: physiochemical characterization of reference e-liquid

    Directory of Open Access Journals (Sweden)

    Jeffrey J. Kim

    2017-02-01

    The efforts described here to create a standardized e-liquid Reference Material aim to provide unbiased and robust testing parameters that may be useful for researchers, the industry and government agencies. Additionally, the reference e-liquid could open a channel of conversation among different laboratories by providing the means of independent verification and validation while establishing a system of transparency and reproducibility in materials and methods.

  15. Element concentrations in candidate biological and environmental reference materials by k0-standardized INAA

    International Nuclear Information System (INIS)

    Freitas, M.C.

    1993-01-01

    K 0 -Based Neutron Activation Analysis (k 0 INAA) was used to analyze the candidate reference materials Apple Leaves and Peach Leaves, and Oriental Tobacco Leaves and Virginia Tobacco Leaves. Concentration values for 27 elements were measured. The accuracy was ascertained by analysis of two certified reference materials. NIST 1572 Citrus Leaves and 1573 Tomato Leaves. The homogeneity test of the IAEA Evernia prunastri candidate reference material in aliquots ≥ 100 mg is extended to the elements Sc, Cr, Fe, Co, Zn, Rb, Sb, Cs, Ba, Ce and Th. (orig.)

  16. Preparation and characterization of the fish reference material; Preparacao e caracterizacao de um material de referencia de peixe

    Energy Technology Data Exchange (ETDEWEB)

    Ulrich, Joao Cristiano

    2011-07-01

    The certified reference materials (CRMs) play an important role in obtaining measurement results traceable to the International System of Units, through an unbroken chain of comparisons. Thus, the demand for new certified reference materials (CRMs) increases every day in all areas of knowledge. The availability of reference materials, mainly in Brazil is still incipient, given that the demand far exceeds the available variety of these materials. The amount of certified reference materials available in the country is insufficient to meet the need of the scientific community and demands for development of new methodologies. Among the many areas in need of reference materials, we highlight the importance for the food trade balance for these products within the country. The certification of food products, intended both for export and for domestic consumption, requires analysis methods that provide precise and accurate results to ensure product quality. This paper describes the preparation and certification of a reference material in the fish matrix in mercury and methylmercury. The study brings together since the stage of material selection, preparation, development of homogeneity and stability studies and characterization. The certification was performed by means of measurements using two analytical techniques, flow injection analysis - cold vapor atomic absorption spectrometry (FIA-CV-AAS) and isotope dilution applied to mass spectrometry (IDMS), which is a primary method. In this work the standards of the ISO 30 (ABNT 30-34) and ISO Guide 35 was used as the basis for the preparation and characterization of the material. For the calculation of uncertainties was used the GUM and Eurachem guide. As a result, was produced and certified a lot of material in relation to the concentration of mercury (Hg = 0.271 {+-} 0.057 mg g{sup -1}) and methylmercury (MeHg = 0.245 {+-} 0.038 mg g{sup -1}), and informational values of lead and arsenic. (author)

  17. Soluble phthalocyanines: perspective materials for electronics

    Czech Academy of Sciences Publication Activity Database

    Nešpůrek, Stanislav; Chaidogiannos, G.; Glezos, N.; Wang, G.; Böhm, S.; Rakušan, J.; Karásková, M.

    2007-01-01

    Roč. 468, č. 2 (2007), 3/[355]-21/[373] ISSN 1542-1406 R&D Projects: GA AV ČR KAN401770651; GA MPO FT-TA/036; GA MŠk OC 138 Institutional research plan: CEZ:AV0Z40500505 Keywords : FET transistors * humidity sensors * organic semiconductors Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering Impact factor: 0.554, year: 2007

  18. First Principles Calculations of Electronic Excitations in 2D Materials

    DEFF Research Database (Denmark)

    Rasmussen, Filip Anselm

    electronic transport, optical and chemical properties. On the other hand it has shown to be a great starting point for a systematic pertubation theory approach to obtain the so-called quasiparticle spectrum. In the GW approximation one considers the considers the potential from a charged excitation...... as if it is being screened by the electrons in the material. This method has been very successful for calculating quasiparticle energies of bulk materials but results have been more varying for 2D materials. The reason is that the 2D confined electrons are less able to screen the added charge and some...

  19. Electron holography of Fe-based nanocrystalline magnetic materials (invited)

    International Nuclear Information System (INIS)

    Shindo, Daisuke; Park, Young-Gil; Gao, Youhui; Park, Hyun Soon

    2004-01-01

    Magnetic domain structures of nanocrystalline magnetic materials were extensively investigated by electron holography with a change in temperature or magnetic field applied. In both soft and hard magnetic materials, the distribution of lines of magnetic flux clarified in situ by electron holography was found to correspond well to their magnetic properties. An attempt to produce a strong magnetic field using a sharp needle made of a permanent magnet, whose movement is controlled by piezo drives has been presented. This article demonstrates that the attempt is promising to investigate the magnetization process of hard magnetic materials by electron holography

  20. High Resolution Electron Microscopy in Materials Science

    International Nuclear Information System (INIS)

    Amelinckx, S.

    1986-01-01

    This paper illustrates different operating modes of the electron microscope and shows the image formation in an ideal microscope. Diffraction contrast is used in the study of crystal defects, such as dislocations and planar interfaces. Methods are surveyed which give at least a rudimentary image of the lattice and therefore make use of at least two interfering beams. Special attention is given to images which also carry structural information and therefore imply the use of many beams. The underlying theory is discussed as are the theories of Van Dyck, Spence and Cowley. These are illustrated by means of a number of recent case studies

  1. Homogeneity test of the ceramic reference materials for non-destructive quantitative

    International Nuclear Information System (INIS)

    Li Li; Fong Songlin; Zhu Jihao; Feng Xiangqian; Xie Guoxi; Yan Lingtong

    2010-01-01

    In order to study elemental composition of ancient porcelain samples, we developed a set of ceramic reference materials for non-destructive quantitative analysis. In this paper,homogeneity of Al, Si, K, Ca, Ti, Mn and Fe contents in the ceramic reference materials is investigated by EDXRF. The F test and the relative standard deviation are used to treat the normalized net counts by SPSS. The results show that apart from the DY2 and JDZ4 reference materials, to which further investigation would be needed, homogeneity of the DH, DY3, JDZ3, JDZ6, GY1, RY1, LQ4, YJ1, YY2 and JY2 meets the requirements of ceramic reference materials for non-destructive quantitative analysis. (authors)

  2. Normalization Methods and Selection Strategies for Reference Materials in Stable Isotope Analyes. Review

    Energy Technology Data Exchange (ETDEWEB)

    Skrzypek, G. [West Australian Biogeochemistry Centre, John de Laeter Centre of Mass Spectrometry, School of Plant Biology, University of Western Australia, Crawley (Australia); Sadler, R. [School of Agricultural and Resource Economics, University of Western Australia, Crawley (Australia); Paul, D. [Department of Civil Engineering (Geosciences), Indian Institute of Technology Kanpur, Kanpur (India); Forizs, I. [Institute for Geochemical Research, Hungarian Academy of Sciences, Budapest (Hungary)

    2013-07-15

    Stable isotope ratio mass spectrometers are highly precise, but not accurate instruments. Therefore, results have to be normalized to one of the isotope scales (e.g., VSMOW, VPDB) based on well calibrated reference materials. The selection of reference materials, numbers of replicates, {delta}-values of these reference materials and normalization technique have been identified as crucial in determining the uncertainty associated with the final results. The most common normalization techniques and reference materials have been tested using both Monte Carlo simulations and laboratory experiments to investigate aspects of error propagation during the normalization of isotope data. The range of observed differences justifies the need to employ the same sets of standards worldwide for each element and each stable isotope analytical technique. (author)

  3. Determination of trimethyllead reference material using high performance liquid chromatography-inductively coupled plasma mass spectrometry

    International Nuclear Information System (INIS)

    Lu Hai; Wei Chao; Wang Jun; Chao Jingbo; Zhou Tao; Chen Dazhou

    2005-01-01

    A high-performance liquid chromatography-inductively coupled plasma mass spectrometry (HPLC-ICPMS) was combined, and the chromatography conditions were optimized. The stability and homogeneity of a trimethyllead reference material were determined using this method. (authors)

  4. Fresh biological reference materials. Use in inter laboratory studies and as CRMs

    International Nuclear Information System (INIS)

    De Boer, J.

    1999-01-01

    Biological reference materials were prepared and packed in tins and glass jars to be used in inter laboratory studies on chlorobiphenyls and organochlorine pesticides, and trace metals, respectively. The materials were homogenised, sterilised and packed as wet tissue, which is unique for the purpose of inter laboratory studies and offers the advantage of studying the extraction and destruction steps of the analytical methods. In addition to their use in inter laboratory studies, some materials have been prepared or are being prepared as certified reference material for chlorobiphenyl analysis. (author)

  5. Evaluation of Botanical Reference Materials for the Determination of Vanadium in Biological Samples

    DEFF Research Database (Denmark)

    Heydorn, Kaj; Damsgaard, Else

    1982-01-01

    Three botanical reference materials prepared by the National Bureau of Standards have been studied by neutron activation analysis to evaluate their suitability with respect to the determination of vanadium in biological samples. Various decomposition methods were applied in connection with chemic....... A reference value of 1.15 mg/kg of this material is recommended, based on results from 3 different methods. All three materials are preferable to SRM 1571 Orchard Leaves, while Bowen's Kale remains the material of choice because of its lower concentration....

  6. Holmium hafnate: An emerging electronic device material

    International Nuclear Information System (INIS)

    Pavunny, Shojan P.; Sharma, Yogesh; Kooriyattil, Sudheendran; Dugu, Sita; Katiyar, Rajesh K.; Katiyar, Ram S.; Scott, James F.

    2015-01-01

    We report structural, optical, charge transport, and temperature properties as well as the frequency dependence of the dielectric constant of Ho 2 Hf 2 O 7 (HHO) which make this material desirable as an alternative high-k dielectric for future silicon technology devices. A high dielectric constant of ∼20 and very low dielectric loss of ∼0.1% are temperature and voltage independent at 100 kHz near ambient conditions. The Pt/HHO/Pt capacitor exhibits exceptionally low Schottky emission-based leakage currents. In combination with the large observed bandgap E g of 5.6 eV, determined by diffuse reflectance spectroscopy, our results reveal fundamental physics and materials science of the HHO metal oxide and its potential application as a high-k dielectric for the next generation of complementary metal-oxide-semiconductor devices

  7. Holmium hafnate: An emerging electronic device material

    Science.gov (United States)

    Pavunny, Shojan P.; Sharma, Yogesh; Kooriyattil, Sudheendran; Dugu, Sita; Katiyar, Rajesh K.; Scott, James F.; Katiyar, Ram S.

    2015-03-01

    We report structural, optical, charge transport, and temperature properties as well as the frequency dependence of the dielectric constant of Ho2Hf2O7 (HHO) which make this material desirable as an alternative high-k dielectric for future silicon technology devices. A high dielectric constant of ˜20 and very low dielectric loss of ˜0.1% are temperature and voltage independent at 100 kHz near ambient conditions. The Pt/HHO/Pt capacitor exhibits exceptionally low Schottky emission-based leakage currents. In combination with the large observed bandgap Eg of 5.6 eV, determined by diffuse reflectance spectroscopy, our results reveal fundamental physics and materials science of the HHO metal oxide and its potential application as a high-k dielectric for the next generation of complementary metal-oxide-semiconductor devices.

  8. Holmium hafnate: An emerging electronic device material

    Energy Technology Data Exchange (ETDEWEB)

    Pavunny, Shojan P., E-mail: shojanpp@gmail.com, E-mail: rkatiyar@hpcf.upr.edu; Sharma, Yogesh; Kooriyattil, Sudheendran; Dugu, Sita; Katiyar, Rajesh K.; Katiyar, Ram S., E-mail: shojanpp@gmail.com, E-mail: rkatiyar@hpcf.upr.edu [Department of Physics and Institute for Functional Nanomaterials, University of Puerto Rico, P.O. Box 70377, San Juan, Puerto Rico 00936-8377 (United States); Scott, James F. [Department of Physics and Institute for Functional Nanomaterials, University of Puerto Rico, P.O. Box 70377, San Juan, Puerto Rico 00936-8377 (United States); Department of Physics, Cavendish Laboratory, University of Cambridge, Cambridge CB3 OHE (United Kingdom)

    2015-03-16

    We report structural, optical, charge transport, and temperature properties as well as the frequency dependence of the dielectric constant of Ho{sub 2}Hf{sub 2}O{sub 7} (HHO) which make this material desirable as an alternative high-k dielectric for future silicon technology devices. A high dielectric constant of ∼20 and very low dielectric loss of ∼0.1% are temperature and voltage independent at 100 kHz near ambient conditions. The Pt/HHO/Pt capacitor exhibits exceptionally low Schottky emission-based leakage currents. In combination with the large observed bandgap E{sub g} of 5.6 eV, determined by diffuse reflectance spectroscopy, our results reveal fundamental physics and materials science of the HHO metal oxide and its potential application as a high-k dielectric for the next generation of complementary metal-oxide-semiconductor devices.

  9. Use of an excess variance approach for the certification of reference materials by interlaboratory comparison

    International Nuclear Information System (INIS)

    Crozet, M.; Rigaux, C.; Roudil, D.; Tuffery, B.; Ruas, A.; Desenfant, M.

    2014-01-01

    In the nuclear field, the accuracy and comparability of analytical results are crucial to insure correct accountancy, good process control and safe operational conditions. All of these require reliable measurements based on reference materials whose certified values must be obtained by robust metrological approaches according to the requirements of ISO guides 34 and 35. The data processing of the characterization step is one of the key steps of a reference material production process. Among several methods, the use of interlaboratory comparison results for reference material certification is very common. The DerSimonian and Laird excess variance approach, described and implemented in this paper, is a simple and efficient method for the data processing of interlaboratory comparison results for reference material certification. By taking into account not only the laboratory uncertainties but also the spread of the individual results into the calculation of the weighted mean, this approach minimizes the risk to get biased certified values in the case where one or several laboratories either underestimate their measurement uncertainties or do not identify all measurement biases. This statistical method has been applied to a new CETAMA plutonium reference material certified by interlaboratory comparison and has been compared to the classical weighted mean approach described in ISO Guide 35. This paper shows the benefits of using an 'excess variance' approach for the certification of reference material by interlaboratory comparison. (authors)

  10. Assessment of a dynamic reference material for calibration of full-field measurement systems

    Science.gov (United States)

    Hack, Erwin; Feligiotti, Mara; Davighi, Andrea; Whelan, Maurice; Wang, Weizhuo V.; Patterson, Eann A.

    2012-10-01

    For holography and speckle interferometry the calibration of the sensitivity is a must, because illumination and observation directions vary across the field of view. A numerical estimate or a static calibration using rigid body motions is standard, and reference materials exist for static strain calibration. Recently, reference materials for the dynamic calibration of optical instruments of displacement and strain measurement were designed and prototypes were manufactured in the European FP7 project ADVISE. We review the properties of the reference material and the concept of traceability for the field of displacement values by using a calibrated single point transducer. The mode shape is assessed using out-of-plane DSPI, Finite Element Analysis as well as analytic solutions of the plate vibration. We present measurements using stroboscopic DSPI on the reference material under acoustic excitation and compare the measured mode shapes to the ones predicted by FE analysis. We apply different comparison methodologies based on point-by-point deviations and on decomposition of the mode shapes into a set of orthogonal basis functions. The latter method is well suited to assess stability and reproducibility of a mode shape. Finally, the deviations are used to estimate the reference material uncertainty which is an essential parameter for determining the calibration uncertainty. Uncertainty contributions of the DSPI set-up are taken into account. To conclude, the application area and limitations of the reference material are discussed.

  11. Element content and particle size characterization of a mussel candidate reference material

    International Nuclear Information System (INIS)

    Moreira, Edson G.; Vasconcellos, Marina B.A.; Santos, Rafaela G. dos; Martinelli, Jose R.

    2011-01-01

    The use of certified reference materials is an important tool in the quality assurance of analytical measurements. To assure reliability on recently prepared powder reference materials, not only the characterization of the property values of interest and their corresponding uncertainties, but also physical properties such as the particle size distribution must be well evaluated. Narrow particle size distributions are preferable than larger ones; as different size particles may have different analyte content. Due to this fact, the segregation of the coarse and the fine particles in a bottle may lead to inhomogeneity of the reference material, which should be avoided. In this study the element content as well as the particle size distribution of a mussel candidate reference material produced at IPEN-CNEN/SP was investigated. Instrumental Neutron Activation Analysis was applied to the determination of 15 elements in seven fractions of the material with different particle size distributions. Subsamples of the materials were irradiated simultaneously with elemental standards at the IEA-R1 research nuclear reactor and the induced gamma ray energies were measured in a hyperpure germanium detector. Three vials of the candidate reference material and three coarser fractions, collected during the preparation, were analyzed by Laser Diffraction Particle Analysis to determine the particle size distribution. Differences on element content were detected for fractions with different particle size distribution, indicating the importance of particle size control for biological reference materials. From the particle size analysis, Gaussian particle size distribution was observed for the candidate reference material with mean particle size μ = 94.6 ± 0.8 μm. (author)

  12. Determination of multielement in optical waveguide and standard reference materials by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Kobayashi, K.; Kudo, K.

    1979-01-01

    Trace amounts of transition elements (Co, Cr, Cu, Fe, Mn and V) and other seven elements in optical waveguide samples were determined by INAA. The contents of impurities in ultre-pure materials are less than those of high-purity materials and of G.R. grade. The increase of contamination of trace transition elements and iridium from furnace or crucible are observed in the production of optical glass fibers. Up to seventeen elements were determined in five NBS biological standard reference materials: Oyster Tissue: SRM-1566, Brewers Yeast: SRM-1569, Spinach: SRM-1570, Orchard Leaves: SRM-1571 and Tuna Fish, and in four Japanese biological standard reference materials: Tea Leaves B and C, Pepperbush and Shark Meat. The analytical results in NBS and Japanese standard reference materials are in good agreement with published values and certified values by NBS. (author)

  13. Electronic processes in non-crystalline materials

    CERN Document Server

    Mott, Nevill Francis

    2012-01-01

    Since the first edition of this highly successful book the field saw many great developments both in experimental and theoretical studies of electrical properties of non-crystalline solids. It became necessary to rewrite nearly the whole book, while the aims of the second edition remained the same: to set out the theoretical concepts, to test them by comparison with experiment for a wide variety of phenomena, and to apply them to non-crystalline materials. Sir Nevill Mott shared the1977 Nobel Prize for Physics, awarded for his research work in this field. The reissue of this book as part of th

  14. Molecular modeling and multiscaling issues for electronic material applications

    CERN Document Server

    Iwamoto, Nancy; Yuen, Matthew; Fan, Haibo

    Volume 1 : Molecular Modeling and Multiscaling Issues for Electronic Material Applications provides a snapshot on the progression of molecular modeling in the electronics industry and how molecular modeling is currently being used to understand material performance to solve relevant issues in this field. This book is intended to introduce the reader to the evolving role of molecular modeling, especially seen through the eyes of the IEEE community involved in material modeling for electronic applications.  Part I presents  the role that quantum mechanics can play in performance prediction, such as properties dependent upon electronic structure, but also shows examples how molecular models may be used in performance diagnostics, especially when chemistry is part of the performance issue.  Part II gives examples of large-scale atomistic methods in material failure and shows several examples of transitioning between grain boundary simulations (on the atomistic level)and large-scale models including an example ...

  15. Materials Meets Concepts in Molecule-Based Electronics

    KAUST Repository

    Ortmann, Frank; Radke, K. Sebastian; Gü nther, Alrun; Kasemann, Daniel; Leo, Karl; Cuniberti, Gianaurelio

    2014-01-01

    In this contribution, molecular materials are highlighted as an important topic in the diverse field of condensed matter physics, with focus on their particular electronic and transport properties. A better understanding of their performance

  16. Monte Carlo calculations of electron diffusion in materials

    International Nuclear Information System (INIS)

    Schroeder, U.G.

    1976-01-01

    By means of simulated experiments, various transport problems for 10 Mev electrons are investigated. For this purpose, a special Monte-Carlo programme is developed, and with this programme calculations are made for several material arrangements. (orig./LN) [de

  17. Biological and environmental reference materials for trace elements, nuclides and organic microcontaminants

    International Nuclear Information System (INIS)

    Cortes Toro, E.; Parr, R.M.; Clements, S.A.

    1990-01-01

    This report has been produced from a database on analytical reference materials of biological and environmental origin, which is maintained at the International Atomic Energy Agency. It is an updated version of an earlier report, published in 1985, which focussed mainly on reference materials for trace elements. In the present version of the report, reference materials for trace elements still constitute the major part of the data; however, information is also now included on a number of other selected analytes of relevance to IAEA programmes, i.e. radionuclides, stable isotopes and organic microcontaminants. The database presently contains 2,694 analyte values for 117 analytes in 116 biological and 77 environmental (non-biological) reference materials produced by 20 different suppliers. Additional information on the cost of the material, the unit size supplied, (weight or volume), and the minimum weight of material recommended for analysis is also provided (if available to the authors). It is expected that this report will help analysts to select the reference material that matches as closely as possible, with respect to matrix type and concentrations of the analytes of interest, the ''real'' samples that are to be analysed. Refs, 12 tabs

  18. Preparation and certification of rice flour reference materials for trace elements analysis

    International Nuclear Information System (INIS)

    Cho, Kyung Haeng; Park, Chang Joon; Woo, Jin Choon; Suh, Jung Ki; Han, Myung Sub; Lee, Jong Hae

    1998-01-01

    Rice flour reference materials were prepared from the unpolished rice grown in korea and certified for elemental composition. The reference materials consist of two samples containing normal and high level. The reference material at elevated level was prepared by spiking to the normal rice flour six toxic elements of As, Cd, Cu, Cr, Hg, Pb with 1.0μg/g on a dry weight basis. Homogeneity of the prepared materials was evaluated through the determination of Ca, Cu, Fe, Mn, Zn by instrumental neutron activation analysis (INAA) and atomic absorption spectrometry (AAS). Small variance of elemental composition among inter-bottled samples assured homogeneity of the prepared materials. The materials were decomposed by high pres-sure digestion and microwave digestion method. INAA, AAS, inductively coupled plasma-atomic absorption spectrometry (ICP-AES), ICP-mass spectrometry (MS) and vapour generation techniques were employed to analyze the reference materials. From this independent analytical results, the certified or reference values are determined for As, Ca, Cd, Cr, Cu, Fe, Hg, K, Mg, Mn, Mo, Na, P, Pb, Se, Zn

  19. Polish reference material: corn flour (INCT-CF-3)for inorganic trace analysis - preparation and certification

    International Nuclear Information System (INIS)

    Polkowska-Motrenko, H.; Dybczynski, R.; Chajduk, E.; Danko, B.; Kulisa, K.; Samczynski, Z.; Sypula, M.; Szopa, Z.

    2006-01-01

    Preparation, examination and certification of the new matrix reference material of biological origin: Corn Flour (INCT-CF-3) is described. The material was prepared from corn grown in Poland according to Polish standard PN-A-74205:1997. The material was sieved through the 250 mm nylon sieves and stored in a polyethylene (PE) bag. Approximately 50 kg of sieved corn flour was collected. Examination by optical microscopy revealed that Martin's diameter of over 98% of particles was below 25 mm. The whole lot of corn flour was then homogenized by mixing for 20 hours in a 110 dm 3 PE drum rotated in three directions. Preliminary homogeneity testing by X-ray fluorescence (XRF) method and final checking of homogeneity by neutron activation analysis (NAA) after distribution of the material into containers revealed, that it is sufficiently homogeneous at least for a sample size ≥ 100 mg. In order to assure the long-term stability, all containers with INCT-CF-3 were sterilized by electron beam radiation. Long-term stability was checked by analyzing concentrations of selected elements in the material stored in the air-conditioned room at 20 o C. Short-term stability was examined by the determination of concentrations of the selected elements in the bottle stored in the CO 2 incubator at 37 o C. The material was certified on the basis of a worldwide interlaboratory comparison, in which 92 laboratories from 19 countries participated providing 962 laboratory averages (4228 individual determinations) for 57 elements. A method of data evaluation leading to assignment of certified values was the same as that used previously in the Laboratory of the Department of Analytical Chemistry, Institute of Nuclear Chemistry and Technology. The result for Mo was obtained by definitive methods developed in the Laboratory and used to support the certification process. Analytical uncertainties and stability uncertainties were quantified to arrive at combined uncertainties of the certified

  20. Preparation of reference material for organochlorine pesticides in a herbal matrix.

    Science.gov (United States)

    Wong, Yiu Chung; Wong, Siu Kay; Kam, Tat Ting

    2008-12-01

    The development of reference material for four organochlorine pesticides, namely hexachlorobenzene and three isomers of hexachlorocyclohexane (alpha-hexachlorocyclohexane, beta-hexachlorocyclohexane and gamma-hexachlorocyclohexane), in a ginseng root sample is presented. Raw materials (Panax ginseng) were purchased from a local market and confirmed to contain certain levels of incurred organochlorine pesticide residues by a validated gas chromatography-mass selective detection method. A total of more than 300 bottles each containing 25 g of samples were prepared after the materials had been freeze-dried, milled and thoroughly mixed. The homogeneity and stability of samples from randomly selected bottles were verified and the reference values were characterized using a highly precise isotope dilution gas chromatography-mass spectrometry (ID-GCMS) method that was recently developed by our laboratory. The purity of standard organochlorine chemicals was determined against certified reference materials to establish the accuracy of the ID-GCMS analysis. The concentrations (+/- expanded uncertainty) of hexachlorobenzene, alpha-hexachlorocyclohexane, beta-hexachlorocyclohexane and gamma-hexachlorocyclohexane in the reference material were 0.198 +/- 0.015, 0.450 +/- 0.022, 0.213 +/- 0.011 and 0.370 +/- 0.032 mg kg(-1), respectively. A portion (70 bottles) of the samples was also used in a proficiency testing (PT) scheme for assessing the testing capabilities of field laboratories. The consensus mean values of the PT obtained from the 70 participants were on the same order but deviated by -2.7 to -14.1% from those of the assigned reference values. Because of the wide spread of participants' data (relative standard deviation ranging from 44 to 56%), the PT results were not included in the calculation of the assigned values of the reference materials. The materials served as suitable reference materials to ascertain the quality control and validation processes for the

  1. Quantitative micro x-ray fluorescence analyses without reference standard material; Referenzprobenfreie quantitative Mikro-Roentgenfluoreszenzanalyse

    Energy Technology Data Exchange (ETDEWEB)

    Wolff, Timo

    2009-07-15

    X-ray fluorescence analysis (XRF) is a standard method for non-destructive investigations. Due to the development of polycapillary optics and SDDdetectors requiring no cooling with liquid nitrogen, XRF becomes a suitable method for a large number of applications, e. g. for the analysis of objects in arts and archaeology. Spectrometers developed for those purposes allow investigations outside of laboratories und provide excitation areas with diameters of 10-70 {mu}m. In most applications, quantification of XRF data is realized by the usage of standard reference materials. Due to absorption processes in the samples the accuracy of the results depends strongly on the similarity of the sample and the reference standard. In cases where no suitable references are available, quantification can be done based on the ''fundamental parameter (fp) method''. This quantification procedure is based on a set of equations describing the fluorescence production and detection mathematical. The cross sections for the interaction of x-rays with matter can be taken from different databases. During an iteration process the element concentrations can be determined. Quantitative XRF based on fundamental parameters requires an accurate knowledge of the excitation spectrum. In case of a conventional setup this spectrum is given by the X-ray tube spectrum and can be calculated. The use of polycapillary optics in micro-XRF spectrometers changes the spectral distribution of the excitation radiation. For this reason it is necessary to access the transmission function of the used optic. The aim of this work is to find a procedure to describe this function for routine quantification based on fundamental parameters. Most of the measurements have been carried out using a commercial spectrometer developed for applications in arts and archaeology. On the one hand the parameters of the lens, used in the spectrometer, have been investigated by different experimental characterization

  2. New electron microprobe for radioactive materials

    International Nuclear Information System (INIS)

    Perrot, M.; Geoffroy, G.; Trotabas, M.

    1989-01-01

    The latest model of CAMECA microprobe SX 50R has just been set up in the high activity laboratory of the Centre d'Etudes Nucleaires de SACLAY. It has been especially designed for the examination of nuclear fuel and irradiated materials. The spectrometers are protected from the radioactivity by an armour plate and the entire equipment has been installed into a special cell in order to protect the operators. The special sample holder allows to examine specimens as large as 80 mm in diameter. One of the interesting uses concerns the quantitative determination of the oxygen content in zircaloy oxidized by steam at high temperature. This analysis was made possible by using the new type of crystals (multilayer)

  3. Interlaboratory Reproducibility of Droplet Digital Polymerase Chain Reaction Using a New DNA Reference Material Format.

    Science.gov (United States)

    Pinheiro, Leonardo B; O'Brien, Helen; Druce, Julian; Do, Hongdo; Kay, Pippa; Daniels, Marissa; You, Jingjing; Burke, Daniel; Griffiths, Kate; Emslie, Kerry R

    2017-11-07

    Use of droplet digital PCR technology (ddPCR) is expanding rapidly in the diversity of applications and number of users around the world. Access to relatively simple and affordable commercial ddPCR technology has attracted wide interest in use of this technology as a molecular diagnostic tool. For ddPCR to effectively transition to a molecular diagnostic setting requires processes for method validation and verification and demonstration of reproducible instrument performance. In this study, we describe the development and characterization of a DNA reference material (NMI NA008 High GC reference material) comprising a challenging methylated GC-rich DNA template under a novel 96-well microplate format. A scalable process using high precision acoustic dispensing technology was validated to produce the DNA reference material with a certified reference value expressed in amount of DNA molecules per well. An interlaboratory study, conducted using blinded NA008 High GC reference material to assess reproducibility among seven independent laboratories demonstrated less than 4.5% reproducibility relative standard deviation. With the exclusion of one laboratory, laboratories had appropriate technical competency, fully functional instrumentation, and suitable reagents to perform accurate ddPCR based DNA quantification measurements at the time of the study. The study results confirmed that NA008 High GC reference material is fit for the purpose of being used for quality control of ddPCR systems, consumables, instrumentation, and workflow.

  4. A study of production of radioactive environmental reference materials used for proficiency testing program in Taiwan

    International Nuclear Information System (INIS)

    Peng, En-Chi; Wang, Jeng-Jong

    2013-01-01

    To realise radioactive environmental reference materials in Taiwan, seven environmental materials of soil, water, vegetation, meat, airborne particles (filter paper), milk and mushroom samples that are frequently encountered were used to establish the preparation of the reference materials. These seven environmental materials were collected, checked for freedom from radioactivity and prepared according to their properties. The preparation was carried out by using activity about 10–100 times that of the minimum detectable activity (MDA) in routine measurements in the radioactive standard used to spike the inactive material and this standard is traceable to national ionising radioactivity standards (TAF, 2004). To demonstrate sample traceability to the added standard, each sample was carefully measured and its uncertainty evaluated. Based on the recommendations of ISO Guide 35 for evaluation of reference materials and with the above assessment and verification procedures, the uncertainties (k=1) of the spike activity used in making reference materials were: 60 Co≤4.6%, 134 Cs≤4.7%, 137 Cs≤5.0%, total β≤0.6% and 3 H≤1.3%. - Highlights: • Seven kinds environmental materials were used to establish the production of the RMs. • Spiking the traceable standard radioactive source to the blank substance. • Each sample was carefully evaluated for its uncertainty. • The performance of the RMs was estimated with the Proficiency Testing program report. • The ability of the environment RMs in the configuration is quite good

  5. Certified reference materials for food packaging specific migration tests: development, validation and modelling

    NARCIS (Netherlands)

    Stoffers, N.H.

    2005-01-01

    Keywords:certified reference materials; diffusion; food contact materials; food packaging; laurolactam; migration modelling; nylon; specific migration This thesis compiles several research topics

  6. Development of in-plant reference material for composition of chinese cabbage with certified selenium content

    Directory of Open Access Journals (Sweden)

    D. A. Chupahin

    2014-01-01

    Full Text Available In-plant reference material for composition of Chinese cabbage with certified selenium content was developed for accuracy control of the results of selenium determination and within-laboratory quality control of analytical work in the analysis of food raw material.

  7. The preparation and certification of a South African phosphate concentrate for use as a reference material

    International Nuclear Information System (INIS)

    Hansen, R.G.

    1985-01-01

    This report describes the preparation, analysis, and certification of South African Reference Material (SARM) 32. The material is a phosphate concentrate from the Phalaborwa deposit, and was supplied by the Phosphate Development Corporation Ltd (Foskor). Eighteen laboratories in eight countries used a variety of analytical techniques to provide the analytical results

  8. Thallium determination in reference materials by isotope dilution mass spectrometry (IDMS) using thermal ionization

    International Nuclear Information System (INIS)

    Waidmann, E.; Hilpert, K.; Stoeppler, M.

    1990-01-01

    Using Isotope Dilution Mass Spectrometry (IDMS) with thermal ionization, thallium concentrations were determined in reference materials from NIST and BCR, from other sources, and reference materials from the German Environmental Specimen Bank 203 Tl spike solution is applied for the isotope dilution technique. Thallium concentrations in the investigated materials range from 2.67 μg Tl.kg -1 to 963 μg Tl.kg -1 with a relative standard deviation from 0.14 to 10%. The detection limit was 0.1 ng thallium for this work. (orig.)

  9. Report of the research co-ordination meeting on reference materials for microanalytical nuclear techniques

    International Nuclear Information System (INIS)

    1994-01-01

    Many microanalytical procedure require specific natural-matrix reference materials containing very low levels of trace elements and having a high degree of homogeneity. This proposed CRP will specifically address the question of quality control materials for these techniques. The participants of the meeting discussed the requirements for certified reference materials to by used in microanalysis with particular emphasis on the homogeneity issues. This publication contains summary of the discussions along with conclusions and recommendations made by the participants. The publication also contains 13 individual presentations delivered by the participants. Each of the individual papers has been provided with an abstract and indexed separately

  10. Report of the research co-ordination meeting on reference materials for microanalytical nuclear techniques

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1994-07-01

    Many microanalytical procedure require specific natural-matrix reference materials containing very low levels of trace elements and having a high degree of homogeneity. This proposed CRP will specifically address the question of quality control materials for these techniques. The participants of the meeting discussed the requirements for certified reference materials to by used in microanalysis with particular emphasis on the homogeneity issues. This publication contains summary of the discussions along with conclusions and recommendations made by the participants. The publication also contains 13 individual presentations delivered by the participants. Each of the individual papers has been provided with an abstract and indexed separately.

  11. Certified reference materials for the determination of uranium, thorium, and plutonium

    International Nuclear Information System (INIS)

    Santoliquido, P.M.

    1990-01-01

    The New Brunswick Laboratory (NBL) is the Department of Energy's Nuclear Materials Measurements and Standards Laboratory. As part of its mission, NBL provides certified reference materials (CRMs) for the analysis of various types of materials encountered in the nuclear fuel cycle. The reference material program at NBL gained greater prominence in 1981, when an interagency agreement between NBL and NBS established NBL as the distributor of one category of SRMs, the special nuclear materials SRMs. When NBS reorganized and became NIST in 1987, NBL bought out the remaining inventory of these particular SRMs which it was already distributing and renamed them as CRMs. The difference between the radioactivity SRMs which NIST still provides and the nuclear material CRMs which NBL provides will be explained. NBL CRMs are distributed worldwide and are used in nuclear safeguards applications and in geological and environmental research. The current NBL CRM inventory will be described

  12. Nature-Inspired Structural Materials for Flexible Electronic Devices.

    Science.gov (United States)

    Liu, Yaqing; He, Ke; Chen, Geng; Leow, Wan Ru; Chen, Xiaodong

    2017-10-25

    Exciting advancements have been made in the field of flexible electronic devices in the last two decades and will certainly lead to a revolution in peoples' lives in the future. However, because of the poor sustainability of the active materials in complex stress environments, new requirements have been adopted for the construction of flexible devices. Thus, hierarchical architectures in natural materials, which have developed various environment-adapted structures and materials through natural selection, can serve as guides to solve the limitations of materials and engineering techniques. This review covers the smart designs of structural materials inspired by natural materials and their utility in the construction of flexible devices. First, we summarize structural materials that accommodate mechanical deformations, which is the fundamental requirement for flexible devices to work properly in complex environments. Second, we discuss the functionalities of flexible devices induced by nature-inspired structural materials, including mechanical sensing, energy harvesting, physically interacting, and so on. Finally, we provide a perspective on newly developed structural materials and their potential applications in future flexible devices, as well as frontier strategies for biomimetic functions. These analyses and summaries are valuable for a systematic understanding of structural materials in electronic devices and will serve as inspirations for smart designs in flexible electronics.

  13. Evaluation on electrical resistivity of silicon materials after electron ...

    Indian Academy of Sciences (India)

    Home; Journals; Bulletin of Materials Science; Volume 38; Issue 5. Evaluation on ... This research deals with the study of electron beam melting (EBM) methodology utilized in melting silicon material and subsequently discusses on the effect of oxygen level on electrical resistivity change after EBM process. The oxygen ...

  14. 2D Dirac electrons in 3D materials

    NARCIS (Netherlands)

    Ramankutty, S.V.

    2018-01-01

    Quantum materials pack the spooky properties of quantum mechanics into real-life materials you can make, pick up with tweezers and study in the lab. Those of interest to us show special electronic properties of great fundamental interest and have applications potential for future computer and

  15. The role of defects on electron behavior in graphene materials

    NARCIS (Netherlands)

    Cervenka, J.

    2009-01-01

    Graphene-based materials exhibit many unique physical properties that are intriguing for both fundamental science and application purposes. This thesis describes three systems of sp2 bonded carbon: graphite, graphene and fullerene, and studies the electron behavior in these materials and how it is

  16. Critical outlook and trends for environmental reference materials at the Measurements & Testing Generic Activity (European Commission).

    Science.gov (United States)

    Quevauviller, P; Bennink, D; Bøwadt, S

    2001-05-01

    It is now well recognised that the quality control (QC) of all types of analyses, including environmental analyses depends on the appropriate use of reference materials. One of the ways to check the accuracy of methods is based on the use of Certified Reference Materials (CRMs), whereas other types of (not certified) Reference Materials (RMs) are used for routine quality control (establishment of control charts) and interlaboratory testing (e.g. proficiency testing). The perception of these materials, in particular with respect to their production and use, differs widely according to various perspectives (e.g. RM producers, routine laboratories, researchers). This review discusses some critical aspects of RM use and production for the QC of environmental analyses and describes the new approach followed by the Measurements & Testing Generic Activity (European Commission) to tackle new research and production needs.

  17. Proper use of reference materials for trace element analysis and updates on their availability

    International Nuclear Information System (INIS)

    Snell, J.P.

    2009-01-01

    Full text: As different spectroscopic methods are used to certify reference materials (RMs) for element content, there is close interrelation between development of new methods and availability of new certified reference materials (CRMs). The Institute for Reference Materials and Measurements (IRMM) monitors changing scientific and regulatory interests, and adapts materials to current and predicted needs. This includes the development of CRMs with new matrices, or changing analytes and concentration levels for existing types of CRMs. Recent examples are CRMs to support the EC Directives on air quality and water, for nanoparticle characterization, and progressing international standards for biofuel measurements. User guidance including appropriate CRM selection, and use of uncertainties in comparing results will be highlighted. (author)

  18. Soiled-based uranium disequilibrium and mixed uranium-thorium series radionuclide reference materials

    International Nuclear Information System (INIS)

    Donivan, S.; Chessmore, R.

    1988-12-01

    The US Department of Energy (DOE) Office of Remedial Action and Waste Technology has assigned the Technical Measurements Center (TMC), located at the DOE Grand Junction Colorado, Projects Office and operated by UNC Geotech (UNC), the task of supporting ongoing remedial action programs by providing both technical guidance and assistance in making the various measurements required in all phases of remedial action work. Pursuant to this task, the Technical Measurements Center prepared two sets of radionuclide reference materials for use by remedial action contractors and cognizant federal and state agencies. A total of six reference materials, two sets comprising three reference materials each, were prepared with varying concentrations of radionuclides using mill tailings materials, ores, and a river-bottom soil diluent. One set (disequilibrium set) contains varying amounts of uranium with nominal amounts of radium-226. The other set (mixed-nuclide set) contains varying amounts of uranium-238 and thorium-232 decay series nuclides. 14 refs., 10 tabs

  19. Soft electron processor for surface sterilization of food material

    International Nuclear Information System (INIS)

    Baba, Takashi; Kaneko, Hiromi; Taniguchi, Shuichi

    2004-01-01

    As frozen or chilled foods have become popular nowadays, it has become very important to provide raw materials with lower level microbial contamination to food processing companies. Consequently, the sterilization of food material is one of the major topics for food processing. Dried materials like grains, beans and spices, etc., are not typically deeply contaminated by microorganisms, which reside on the surfaces of materials, so it is very useful to take low energetic, lower than 300 keV, electrons with small penetration power (Soft-Electrons), as a sterilization method for such materials. Soft-Electrons is researched and named by Dr. Hayashi et al. This is a non-thermal method, so one can keep foods hygienic without serious deterioration. It is also a physical method, so is free from residues of chemicals in foods. Recently, Nissin-High Voltage Co., Ltd. have developed and manufactured equipment for commercial use of Soft-Electrons (Soft Electron Processor), which can process 500 kg/h of grains. This report introduces the Soft Electron Processor and shows the results of sterilization of wheat and brown rice by the equipment

  20. Application of electron irradiation to food containers and packaging materials

    International Nuclear Information System (INIS)

    Ueno, Koji

    2010-01-01

    Problems caused by microbial contamination and hazardous chemicals have attracted much attention in the food industry. The number of systems such as hygienic management systems and Hazard Analysis Critical Control Point (HACCP) systems adopted in the manufacturing process is increasing. As manufacturing process control has become stricter, stricter control is also required for microbial control for containers and packaging materials (from disinfection to sterilization). Since safe and reliable methods for sterilizing food containers and packaging materials that leave no residue are required, electron beam sterilization used for medical equipment has attracted attention from the food industry. This paper describes an electron irradiation facility, methods for applying electron beams to food containers and packaging materials, and products irradiated with electron beams. (author)

  1. Surface and Interface Physics of Correlated Electron Materials

    Energy Technology Data Exchange (ETDEWEB)

    Millis, Andrew [Columbia Univ., New York, NY (United States)

    2004-09-01

    The {\\it Surface and Interface Physics of Correlated Electron Materials} research program provided conceptual understanding of and theoretical methodologies for understanding the properties of surfaces and interfaces involving materials exhibiting strong electronic correlations. The issues addressed in this research program are important for basic science, because the behavior of correlated electron superlattices is a crucial challenge to and crucial test of our understanding of the grand-challenge problem of correlated electron physics and are important for our nation's energy future because correlated interfaces offer opportunities for the control of phenomena needed for energy and device applications. Results include new physics insights, development of new methods, and new predictions for materials properties.

  2. Performance Enhancement of Organic Light-Emitting Diodes Using Electron-Injection Materials of Metal Carbonates

    Science.gov (United States)

    Shin, Jong-Yeol; Kim, Tae Wan; Kim, Gwi-Yeol; Lee, Su-Min; Shrestha, Bhanu; Hong, Jin-Woong

    2016-05-01

    Performance of organic light-emitting diodes was investigated depending on the electron-injection materials of metal carbonates (Li2CO3 and Cs2CO3 ); and number of layers. In order to improve the device efficiency, two types of devices were manufactured by using the hole-injection material (Teflon-amorphous fluoropolymer -AF) and electron-injection materials; one is a two-layer reference device ( ITO/Teflon-AF/Alq3/Al ) and the other is a three-layer device (ITO/Teflon-AF/Alq3/metal carbonate/Al). From the results of the efficiency for the devices with hole-injection layer and electron-injection layer, it was found that the electron-injection layer affects the electrical properties of the device more than the hole-injection layer. The external-quantum efficiency for the three-layer device with Li2CO3 and Cs2CO3 layer is improved by approximately six and eight times, respectively, compared with that of the two-layer reference device. It is thought that a use of electron-injection layer increases recombination rate of charge carriers by the active injection of electrons and the blocking of holes.

  3. Nanodiamond composite as a material for cold electron emitters

    International Nuclear Information System (INIS)

    Arkhipov, A V; Sominski, G G; Uvarov, A A; Gordeev, S K; Korchagina, S B

    2008-01-01

    Characteristics of field-induced electron emission were investigated for one of newly designed all-carbon materials - nanodiamond composite (NDC). The composite is comprised by 4-6 nm diamond grains covered with 0.2-1 nm-thick graphite-like shells that merge at grain junctions and determine such properties as mechanical strength and high electric conductivity. Large number of uniformly distributed sp 3 -sp 2 interfaces allowed to expect enhanced electron emission in electric field. Combination of these features makes NDC a promising material for cold electron emitters in various applications. Experimental testing confirmed high efficiency of electron emission from NDC. In comparison with previousely tested forms of nanocarbon, NDC emitters demonstrated better stabily and tolerance to performance conditions. Unusual activation scenarios and thermal dependencies of emission characteristics observed in experiments with NDC can add new background for explanation of facilitated electron emission from nanocarbons with relatively 'smooth' surface morphology

  4. Nanodiamond composite as a material for cold electron emitters

    Energy Technology Data Exchange (ETDEWEB)

    Arkhipov, A V; Sominski, G G; Uvarov, A A [St.Petersburg State Polytechnic University, 29 Politchnicheskaya, St.Petersburg, 195251 (Russian Federation); Gordeev, S K; Korchagina, S B [FSUE ' Central Research Institute for Materials' , 8 Paradnaya Street, St.Petersburg, 191014 (Russian Federation)], E-mail: arkhipov@rphf.spbstu.ru

    2008-03-15

    Characteristics of field-induced electron emission were investigated for one of newly designed all-carbon materials - nanodiamond composite (NDC). The composite is comprised by 4-6 nm diamond grains covered with 0.2-1 nm-thick graphite-like shells that merge at grain junctions and determine such properties as mechanical strength and high electric conductivity. Large number of uniformly distributed sp{sup 3}-sp{sup 2} interfaces allowed to expect enhanced electron emission in electric field. Combination of these features makes NDC a promising material for cold electron emitters in various applications. Experimental testing confirmed high efficiency of electron emission from NDC. In comparison with previousely tested forms of nanocarbon, NDC emitters demonstrated better stabily and tolerance to performance conditions. Unusual activation scenarios and thermal dependencies of emission characteristics observed in experiments with NDC can add new background for explanation of facilitated electron emission from nanocarbons with relatively 'smooth' surface morphology.

  5. Student decisions about lecture attendance: do electronic course materials matter?

    Science.gov (United States)

    Billings-Gagliardi, Susan; Mazor, Kathleen M

    2007-10-01

    This study explored whether first-year medical students make deliberate decisions about attending nonrequired lectures. If so, it sought to identify factors that influence these decisions, specifically addressing the potential impact of electronic materials. Medical students who completed first-year studies between 2004 and 2006 responded to an open-ended survey question about their own lecture-attendance decisions. Responses were coded to capture major themes. Students' ratings of the electronic materials were also examined. Most respondents made deliberate attendance decisions. Decisions were influenced by previous experiences with the lecturer, predictions of what would occur during the session itself, personal learning preferences, and learning needs at that particular time, with the overriding goal of maximizing learning. Access to electronic materials did not influence students' choices. Fears that the increasing availability of technology-enhanced educational materials has a negative impact on lecture attendance seem unfounded.

  6. Feasibility Study for the Development of Plutonium Reference Materials for Age Dating in Nuclear Forensics

    International Nuclear Information System (INIS)

    Sturm, M.; Richter, S.; Aregbe, Y.; Wellum, R.; Altzitzoglou, T.; Verbruggen, A.; Mayer, K.; Prohaska, T.

    2010-01-01

    Isotopic reference materials certified for the age of nuclear material (uranium, plutonium) are needed in the fields of nuclear forensics and environmental measurements. Therefore a feasibility study for the development of plutonium reference materials for age dating has been started recently at the Institute for Reference Materials and Measurements (EC-JRC-IRMM). The ''age'' of the material is defined as the time that has passed since the last chemical separation of the mother and daughter isotopes (e.g. 241 Pu and 241 Am). Assuming that the separation has been complete and all the daughter isotopes have been removed from the original material during this last separation, the age of the material can be determined by measuring the ratio of daughter and mother radio-nuclides, e.g. 241 Am/ 241 Pu. At a given time after the last separation and depending on the half lives of the radio-nuclides involved, a certain amount of the daughter radionuclide(s) will be present. For the determination of the unknown age of a material different ''clocks'' can be used; ''clocks'' are pairs of mother and daughter radio-nuclides, such as 241 Am/ 241 Pu, 238 Pu/ 234 U, 239 Pu/ 235 U, 240 Pu/ 236 U, and possibly 242 Pu/ 238 U. For the age estimation of a real sample, such as material seized in nuclear forensics investigations or dust samples in environmental measurements, it is advisable to use more than one clock in order to ensure the reliability of the results and to exclude the possibility that the sample under question is a mixture of two or more materials. Consequently, a future reference material certified for separation date should ideally be certified for more than one ''clock'' or several reference materials for different ''clocks'' should be developed. The first step of this study is to verify the known separation dates of different plutonium materials of different ages and isotopic compositions by measuring the mother ( 238 Pu, 239 Pu, 240 Pu, 241 Pu, 242 Pu) and daughter

  7. The calibration of XRF polyethylene reference materials with k 0-NAA and ICP-AES

    International Nuclear Information System (INIS)

    Swagten, Josefien; Bossus, Daniel; Vanwersch, Hanny

    2006-01-01

    Due to the lack of commercially available polyethylene reference materials for the calibration of X-ray fluorescence spectrometers (XRF), DSM Resolve, in cooperation with PANalytical, prepared and calibrated such a set of standards in 2005. The reference materials were prepared based on the addition of additives to virgin polyethylene. The mentioned additives are added to improve the performance of the polymers. The elements present in additives are tracers for the used additives. The reference materials contain the following elements: F, Na, Mg, Al, Si, P, S, Ca, Ti and Zn in the concentration range of 5 mg/kg for Ti, up to 600 mg/kg for Mg. The calibration of the reference materials, including a blank, was performed using inductively coupled plasma atomic emission spectrometry (ICP-AES) and Neutron Activation Analysis (k 0 -NAA). ICP-AES was used to determine the elements Na, Mg, Al, P, Ca, Ti and Zn whereas k 0 -NAA was used for F, Na, Mg, Al, Ca, Ti and Zn. Over the complete concentration range, a good agreement of the results was found between the both techniques. This project has shown that within DSM Resolve, it is possible to develop and to calibrate homogenous reference materials for XRF

  8. Electrons scattered inside small dust grains of various materials

    International Nuclear Information System (INIS)

    Richterova, Ivana; Beranek, Martin; Pavlu, Jiri; Nemecek, Zdenek; Safrankova, Jana

    2010-01-01

    The dust grain charge in an electron beam is given by a difference in numbers of electrons that fall onto the grain and those leaving it. Electrons with energies exceeding 1 keV can penetrate through submicron-sized dust grains. If the grain is small enough, a yield of these electrons reaches unity but they leave a part of their energy inside the grain and this energy excites secondary electrons. The paper presents a hybrid Monte Carlo code that simulates paths of the primary electrons inside a spherical grain and provides the yield of scattered electrons and their energy spectrum as a function of the grain size and material. This code is based on the Richterovaet al. [Phys. Rev. B 74, 235430 (2006)] model but it includes several corrections important for light materials like carbon or ice. The model was verified using experimental results obtained on large planar samples. For spherical samples, we have found that the yield of scattered electrons reaches unity for 50 nm Au grains illuminated by 5 keV electrons, whereas the same effect can be observed on ≅1000 nm carbon grains.

  9. Diagnostic value of different adherence measures using electronic monitoring and virologic failure as reference standards.

    Science.gov (United States)

    Deschamps, Ann E; De Geest, Sabina; Vandamme, Anne-Mieke; Bobbaers, Herman; Peetermans, Willy E; Van Wijngaerden, Eric

    2008-09-01

    Nonadherence to antiretroviral therapy is a substantial problem in HIV and jeopardizes the success of treatment. Accurate measurement of nonadherence is therefore imperative for good clinical management but no gold standard has been agreed on yet. In a single-center prospective study nonadherence was assessed by electronic monitoring: percentage of doses missed and drug holidays and by three self reports: (1) a visual analogue scale (VAS): percentage of overall doses taken; (2) the Swiss HIV Cohort Study Adherence Questionnaire (SHCS-AQ): percentage of overall doses missed and drug holidays and (3) the European HIV Treatment Questionnaire (EHTQ): percentage of doses missed and drug holidays for each antiretroviral drug separately. Virologic failure prospectively assessed during 1 year, and electronic monitoring were used as reference standards. Using virologic failure as reference standard, the best results were for (1) the SHCS-AQ after electronic monitoring (sensitivity, 87.5%; specificity, 78.6%); (2) electronic monitoring (sensitivity, 75%; specificity, 85.6%), and (3) the VAS combined with the SHCS-AQ before electronic monitoring (sensitivity, 87.5%; specificity, 58.6%). The sensitivity of the complex EHTQ was less than 50%. Asking simple questions about doses taken or missed is more sensitive than complex questioning about each drug separately. Combining the VAS with the SHCS-AQ seems a feasible nonadherence measure for daily clinical practice. Self-reports perform better after electronic monitoring: their diagnostic value could be lower when given independently.

  10. High-precision isotopic characterization of USGS reference materials by TIMS and MC-ICP-MS

    Science.gov (United States)

    Weis, Dominique; Kieffer, Bruno; Maerschalk, Claude; Barling, Jane; de Jong, Jeroen; Williams, Gwen A.; Hanano, Diane; Pretorius, Wilma; Mattielli, Nadine; Scoates, James S.; Goolaerts, Arnaud; Friedman, Richard M.; Mahoney, J. Brian

    2006-08-01

    The Pacific Centre for Isotopic and Geochemical Research (PCIGR) at the University of British Columbia has undertaken a systematic analysis of the isotopic (Sr, Nd, and Pb) compositions and concentrations of a broad compositional range of U.S. Geological Survey (USGS) reference materials, including basalt (BCR-1, 2; BHVO-1, 2), andesite (AGV-1, 2), rhyolite (RGM-1, 2), syenite (STM-1, 2), granodiorite (GSP-2), and granite (G-2, 3). USGS rock reference materials are geochemically well characterized, but there is neither a systematic methodology nor a database for radiogenic isotopic compositions, even for the widely used BCR-1. This investigation represents the first comprehensive, systematic analysis of the isotopic composition and concentration of USGS reference materials and provides an important database for the isotopic community. In addition, the range of equipment at the PCIGR, including a Nu Instruments Plasma MC-ICP-MS, a Thermo Finnigan Triton TIMS, and a Thermo Finnigan Element2 HR-ICP-MS, permits an assessment and comparison of the precision and accuracy of isotopic analyses determined by both the TIMS and MC-ICP-MS methods (e.g., Nd isotopic compositions). For each of the reference materials, 5 to 10 complete replicate analyses provide coherent isotopic results, all with external precision below 30 ppm (2 SD) for Sr and Nd isotopic compositions (27 and 24 ppm for TIMS and MC-ICP-MS, respectively). Our results also show that the first- and second-generation USGS reference materials have homogeneous Sr and Nd isotopic compositions. Nd isotopic compositions by MC-ICP-MS and TIMS agree to within 15 ppm for all reference materials. Interlaboratory MC-ICP-MS comparisons show excellent agreement for Pb isotopic compositions; however, the reproducibility is not as good as for Sr and Nd. A careful, sequential leaching experiment of three first- and second-generation reference materials (BCR, BHVO, AGV) indicates that the heterogeneity in Pb isotopic compositions

  11. Introduction to organic electronic and optoelectronic materials and devices

    CERN Document Server

    Sun, Sam-Shajing

    2008-01-01

    Introduction to Optoelectronic Materials, N. Peyghambarian and M. Fallahi Introduction to Optoelectronic Device Principles, J. Piprek Basic Electronic Structures and Charge Carrier Generation in Organic Optoelectronic Materials, S.-S. Sun Charge Transport in Conducting Polymers, V.N. Prigodin and A.J. Epstein Major Classes of Organic Small Molecules for Electronic and Optoelectronics, X. Meng, W. Zhu, and H. Tian Major Classes of Conjugated Polymers and Synthetic Strategies, Y. Li and J. Hou Low Energy Gap, Conducting, and Transparent Polymers, A. Kumar, Y. Ner, and G.A. Sotzing Conjugated Polymers, Fullerene C60, and Carbon Nanotubes for Optoelectronic Devices, L. Qu, L. Dai, and S.-S. Sun Introduction of Organic Superconducting Materials, H. Mori Molecular Semiconductors for Organic Field-Effect Transistors, A. Facchetti Polymer Field-Effect Transistors, H.G.O. Sandberg Organic Molecular Light-Emitting Materials and Devices, F. So and J. Shi Polymer Light-Emitting Diodes: Devices and Materials, X. Gong and ...

  12. Micro-homogeneity evaluation of a bovine kidney candidate reference material

    Energy Technology Data Exchange (ETDEWEB)

    Castro, Liliana; Moreira, Edson G.; Vasconcellos, Marina B.A., E-mail: lcastroesnal@usp.br [Instituto de Pesquisas Energéticas e Nucleares (IPEN/CNEN-SP), São Paulo, SP (Brazil)

    2017-07-01

    The minimum sample intake for which a reference material remains homogeneous is one of the parameters that must be estimated in the homogeneity assessment study of reference materials. In this work, Instrumental Neutron Activation Analysis was used to evaluate this quantity in a bovine kidney candidate reference material. The mass fractions of 9 inorganic constituents were determined in subsamples between 1 and 2 mg in order to estimate the relative homogeneity factor (HE) and the minimum sample mass to achieve 5% and 10% precision on a 95% confidence level. Results obtained for H{sub E} in all the analyzed elements were satisfactory. The estimated minimum sample intake was between 2 mg and 40 mg, depending on the element. (author)

  13. River bottom sediment from the Vistula as matrix of candidate for a new reference material.

    Science.gov (United States)

    Kiełbasa, Anna; Buszewski, Bogusław

    2017-08-01

    Bottom sediments are very important in aquatic ecosystems. The sediments accumulate heavy metals and compounds belonging to the group of persistent organic pollutants. The accelerated solvent extraction (ASE) was used for extraction of 16 compounds from PAH group from bottom sediment of Vistula. For the matrix of candidate of a new reference material, moisture content, particle size, loss on ignition, pH, and total organic carbon were determined. A gas chromatograph with a selective mass detector (GC/MS) was used for the final analysis. The obtained recoveries were from 86% (SD=6.9) for anthracene to 119% (SD=5.4) for dibenzo(ah)anthracene. For the candidate for a new reference material, homogeneity and analytes content were determined using a validated method. The results are a very important part of the development and certification of a new reference materials. Copyright © 2017 Elsevier Inc. All rights reserved.

  14. Preparation and development of new Pu spike isotopic reference materials at IRMM

    Energy Technology Data Exchange (ETDEWEB)

    Jakopic, Rozle; Bauwens, Jeroen; Richter, Stephan; Sturm, Monika; Verbruggen, Andre; Wellum, Roger; Eykens, Roger; Kehoe, Frances; Kuehn, Heinz; Aregbe, Yetunde [Institute for Reference Materials and Measurements (IRMM) Joint Research Centre, European Commission, Geel, (Belgium)

    2011-12-15

    Reliable isotope measurements of nuclear material and the availability of reference materials with small uncertainties in the certified values are of great importance for safeguarding of nuclear materials. They provide the basis for a credible measurement system in the verification of states declarations of their nuclear activities. Worldwide needs for continued and improved Isotopic Reference Materials (IRM) are the main reason for developments of new nuclear reference materials at IRMM. Measurement capabilities of laboratories have evolved considerably over the years, along with progress in modern analytical techniques. Some plutonium reference materials, however, have been on the market for decades and they need to be re-certified to smaller uncertainties. Moreover, new reference materials with appropriately small uncertainties in the certified values need to be made available enabling measurement laboratories to reduce their combined measurement uncertainties. Such high quality plutonium isotopic reference materials are essential for laboratories striving to meet the International Target Values for Measurement Uncertainties in Safeguarding Nuclear Materials (ITVs). The preparation and the certification of such materials are demanding and challenging tasks that require state-of-theart measurement procedures and equipment. The Institute for Reference Materials and Measurements (IRMM) has repeatedly demonstrated its capabilities in plutonium analysis and represents one of the few institutes that supplies plutonium IRMs worldwide. An inter-calibration campaign has been set up at IRMM inter-linking selected plutonium spike IRMs. In the scope of this compatibility study, new reference materials have been prepared for Isotope Dilution Mass Spectrometry (IDMS) in nuclear fuel cycle measurements. A new series of large-sized dried (LSD) spikes, IRMM- 1027n, has been prepared and certified for plutonium and uranium amount content and isotopic composition. These mixed

  15. Realization of a tilted reference wave for electron holography by means of a condenser biprism

    Energy Technology Data Exchange (ETDEWEB)

    Röder, Falk, E-mail: Falk.Roeder@tu-dresden.de [Triebenberg Labor, Institut für Strukturphysik, Technische Universität Dresden, D-01062 Dresden (Germany); CEMES-CNRS and Université de Toulouse, 29 rue Jeanne Marvig, F-31055 Toulouse (France); Houdellier, Florent; Denneulin, Thibaud; Snoeck, Etienne; Hÿtch, Martin [CEMES-CNRS and Université de Toulouse, 29 rue Jeanne Marvig, F-31055 Toulouse (France)

    2016-02-15

    As proposed recently, a tilted reference wave in off-axis electron holography is expected to be useful for aberration measurement and correction. Furthermore, in dark-field electron holography, it is considered to replace the reference wave, which is conventionally diffracted in an unstrained object area, by a well-defined object-independent reference wave. Here, we first realize a tilted reference wave by employing a biprism placed in the condenser system above three condenser lenses producing a relative tilt magnitude up to 20/nm at the object plane (300 kV). Paraxial ray-tracing predicts condenser settings for a parallel illumination at the object plane, where only one half of the round illumination disc is tilted relative to the optical axis without displacement. Holographic measurements verify the kink-like phase modulation of the incident beam and return the interference fringe contrast as a function of the relative tilt between both parts of the illumination. Contrast transfer theory including condenser aberrations and biprism instabilities was applied to explain the fringe contrast measurement. A first dark-field hologram with a tilted – object-free – reference wave was acquired and reconstructed. A new application for bright/dark-field imaging is presented.

  16. Combating illicit trafficking in nuclear and other radioactive material. Reference material

    International Nuclear Information System (INIS)

    2007-01-01

    This publication is intended for individuals and organizations that may be called upon to deal with the detection of and response to criminal or unauthorized acts involving nuclear or other radioactive material. It will also be useful for legislators, law enforcement agencies, government officials, technical experts, lawyers, diplomats and users of nuclear technology. This manual emphasizes the international initiatives for improving the security of nuclear and other radioactive material. However, it is recognized that effective measures for controlling the transfer of equipment, non-nuclear material, technology or information that may assist in the development of nuclear explosive devices, improvised nuclear devices (INDs) or other radiological dispersal devices (RDDs) are important elements of an effective nuclear security system. In addition, issues of personal integrity, inspection and investigative procedures are not discussed in this manual, all of which are essential elements for an effective overall security system. The manual considers a variety of elements that are recognized as being essential for dealing with incidents of criminal or unauthorized acts involving nuclear and other radioactive material. Depending on conditions in a specific State, including its legal and governmental infrastructure, some of the measures discussed will need to be adapted to suit that State's circumstances. However, much of the material can be applied directly in the context of other national programmes. This manual is divided into four main parts. Section 2 discusses the threat posed by criminal or unauthorized acts involving nuclear and other radioactive material, as well as the policy and legal bases underlying the international effort to restrain such activities. Sections 3 and 4 summarize the major international undertakings in the field. Sections 5-8 provide some basic technical information on radiation, radioactive material, the health consequences of radiation

  17. The use of high accuracy NAA for the certification of NIST botanical standard reference materials

    International Nuclear Information System (INIS)

    Becker, D.A.; Greenberg, R.R.; Stone, S.F.

    1992-01-01

    Neutron activation analysis is one of many analytical techniques used at the National Institute of Standards and Technology (NIST) for the certification of NIST Standard Reference Materials (SRMs). NAA competes favorably with all other techniques because of it's unique capabilities for high accuracy even at very low concentrations for many elements. In this paper, instrumental and radiochemical NAA results are described for 25 elements in two new NIST SRMs, SRM 1515 (Apple Leaves) and SRM 1547 (Peach Leaves), and are compared to the certified values for 19 elements in these two new botanical reference materials. (author) 7 refs.; 4 tabs

  18. Use of reference materials for quality control of elemental analysis by neutron activation with radiochemical separation

    International Nuclear Information System (INIS)

    Woittiez, J.R.W.

    1990-01-01

    This paper describes the use of certified reference materials to monitor the long-term quality of radiochemical separations. The practical limitations which determine the actual design of the quality control are discussed. The hypothesis that the high yield of the radiochemical separation will be constant with time has been checked and validated for the elements Zn, Fe, Co, Cd, Mo and to a lesser extent for W and Th using NBS SRM 1577A, BCR CRM 274 and IAEA RM A-11. This validation could not be made for the elements Cr, Au, and Ag. Especially for Cr there is a serious lack of appropiate certified reference materials. (orig.)

  19. Development of a certified reference materials for composition of citric acid

    Directory of Open Access Journals (Sweden)

    D. H. Kulev

    2014-01-01

    Full Text Available The paper presents a summary of analyzing Technical Regulations of the Customs Union TR TC 029/2012 "Safety Requirements for Food Additives, Flavorings and Technological Processing Aids". Information on certified reference materials (RMs for composition of citric acid is provided. Certified characteristics of the RM are, on the one hand, mass fraction of the base substance and, on the other hand, mass fraction of impurities - toxic elements (lead, arsenic, cadmium, mercury. The first batches of the given RMs are produced, which are registered in the State Register of the approved types of certified reference materials GS010300-2013 and GS010143-2012.

  20. Instrumental neutron activation analysis for the certification of biological reference materials

    International Nuclear Information System (INIS)

    Ambulkar, M.N.; Chutke, N.L.; Garg, A.N.

    1992-01-01

    A multielemental instrumental neutron activation analysis (INAA) method by short and long irradiation has been employed for the determination of 22 minor and trace constituents in two proposed Standard Reference Materials P-RBF and P-WBF from Institute of Radioecology and Applied Nuclear Techniques, Czechoslovakia. Also some biological standards such as Bowen's Kale, Cabbage leaves (Poland) including wheat and rice flour samples of local origin were analysed. It is suggested that INAA is an ideal method for the certification of reference materials of biological matrices. (author). 7 refs., 1 tab

  1. Materials and Reliability Handbook for Semiconductor Optical and Electron Devices

    CERN Document Server

    Pearton, Stephen

    2013-01-01

    Materials and Reliability Handbook for Semiconductor Optical and Electron Devices provides comprehensive coverage of reliability procedures and approaches for electron and photonic devices. These include lasers and high speed electronics used in cell phones, satellites, data transmission systems and displays. Lifetime predictions for compound semiconductor devices are notoriously inaccurate due to the absence of standard protocols. Manufacturers have relied on extrapolation back to room temperature of accelerated testing at elevated temperature. This technique fails for scaled, high current density devices. Device failure is driven by electric field or current mechanisms or low activation energy processes that are masked by other mechanisms at high temperature. The Handbook addresses reliability engineering for III-V devices, including materials and electrical characterization, reliability testing, and electronic characterization. These are used to develop new simulation technologies for device operation and ...

  2. Preparation and characterization of a Perna perna (Linnaeus, 1758) mussel reference material

    International Nuclear Information System (INIS)

    Moreira, Edson Goncalves

    2010-01-01

    The use of certified reference materials in chemical analysis is an important requirement in quality assurance systems, as it allows the validation of analytical methods and the realization of the metrological traceability of results. Then, it is possible to obtain valid and comparable results not only in space, but also in time. In this study, all the steps for the preparation of a national mussel reference material were attained, from the collection of the bulk material to processing steps such as freeze-drying, grinding, bottling and sterilization. Internationally accepted principles were applied for the homogeneity and stability assessment of the material, using instrumental neutron activation analysis and atomic absorption spectrometry as analytical techniques. By means of a collaborative program with participation of Brazilian and foreign laboratories, the chemical characterization of the material was performed. Element content in the mass percentage to mg kg -1 range was determined for 47 elements and some radionuclides, naturally present in the material. With the application of suitable statistical treatment to the data, it was considered that the content of 11 of those elements may be certified: As, Ca, Cl, Co, K, Mg, Mn, Na, Se, Th and Zn. This study may be considered an important step in the national metrological development, as it shows that the production and characterization of biological reference materials, mussel in particular, is feasible in Brazil, as a tool for quality assurance of environmental and nutritional studies performed in the country. (author)

  3. Certified reference materials for the determination of mineral oil hydrocarbons in water, soil and waste

    Energy Technology Data Exchange (ETDEWEB)

    Koch, M.; Liebich, A.; Win, T.; Nehls, I.

    2005-07-01

    The international research project HYCREF, funded by the European Commission in the 5{sup th} Framework programme, aimed to develop methods to prepare homogeneous and stable water-, soil- and waste reference materials contaminated with mineral oil hydrocarbons and to test certify the mineral oil content by gas chromatographic methods. As mineral oil products are important sources for environmental contaminations a high need exists for certified reference materials for their determination using the new gas chromatographic methods (soil: ISO/FDIS 16703, waste: ENpr 14039, water: ISO 9377-2). The experimental conditions and results for preparation and characterisation of a total of nine reference materials (3 water, 3 soil- and 3 waste materials) are described and discussed. Target values for the reference materials were defined at the beginning of the project in order to have clear quality criteria, which could be compared with the achieved results at the end of the project. These target specifications were related to the maximum uncertainty from test certification exercises (<5% for soil/waste and <10% for water), the maximum inhomogeneity between bottles (<3%) and minimum requirements for stability (>5 years for soil/waste and >2 years for water). The feasibility studies showed that solid materials (soil, waste) could be prepared sufficiently homogeneous and stable. The test certified values of the 6 solid materials comprise a wide range of mineral oil content from about 200-9000 mg/kg with expanded uncertainties between 5.7-13.1% using a coverage factor k (k=2). The development of new water reference materials - the so-called ''spiking pills'' for an offshore- and a land-based discharge water represents one of the most innovative aspects of the project. The spiking pill technology facilitates the application and storage and improves the material stability compared with aqueous materials. Additional to the preparation and test certification of

  4. Assessment of international reference materials for isotope-ratio analysis (IUPAC Technical Report)

    Science.gov (United States)

    Brand, Willi A.; Coplen, Tyler B.; Vogl, Jochen; Rosner, Martin; Prohaska, Thomas

    2014-01-01

    Since the early 1950s, the number of international measurement standards for anchoring stable isotope delta scales has mushroomed from 3 to more than 30, expanding to more than 25 chemical elements. With the development of new instrumentation, along with new and improved measurement procedures for studying naturally occurring isotopic abundance variations in natural and technical samples, the number of internationally distributed, secondary isotopic reference materials with a specified delta value has blossomed in the last six decades to more than 150 materials. More than half of these isotopic reference materials were produced for isotope-delta measurements of seven elements: H, Li, B, C, N, O, and S. The number of isotopic reference materials for other, heavier elements has grown considerably over the last decade. Nevertheless, even primary international measurement standards for isotope-delta measurements are still needed for some elements, including Mg, Fe, Te, Sb, Mo, and Ge. It is recommended that authors publish the delta values of internationally distributed, secondary isotopic reference materials that were used for anchoring their measurement results to the respective primary stable isotope scale.

  5. Electronic and Ionic Conductors from Ordered Microporous Materials

    Energy Technology Data Exchange (ETDEWEB)

    Dincă, Mircea [Massachusetts Inst. of Technology (MIT), Cambridge, MA (United States)

    2017-10-30

    The proposed work aimed to establish metal-organic frameworks (MOFs) as new classes of high-surface area microporous electronic and ionic conductors. MOFs are crystalline materials with pore sizes ranging from 0.2 to ~ 2 nm (or larger for the latter) defined by inorganic or organic building blocks connected by rigid organic linkers. Myriad applications have been found or proposed for these materials, yet those that require electron transport or conductivity in combination with permanent porosity still lag behind because the vast majority of known frameworks are electrical insulators. Prior to our proposal and subsequent work, there were virtually no studies exploring the possibility of electronic delocalization in these materials. Therefore, our primary goal was to understand and control, at a fundamental level, the electron and ion transport properties of this class of materials, with no specific application proposed, although myriad applications could be envisioned for high surface area conductors. Our goals directly addressed one of the DOE-identified Grand Challenges for Basic Energy Sciences: designing perfect atom- and energy-efficient syntheses of revolutionary new forms of matter with tailored properties. Indeed, the proposed work is entirely synthetic in nature; owing to the molecular nature of the building blocks in MOFs, there is the possibility of unprecedented control over the structure and properties of solid crystalline matter. The goals also tangentially addressed the Grand Challenge of controlling materials processes at the level of electrons: the scope of our program is to create new materials where charges (electrons and/or ions) move according to predefined pathways.

  6. Ultrafast electron microscopy in materials science, biology, and chemistry

    International Nuclear Information System (INIS)

    King, Wayne E.; Campbell, Geoffrey H.; Frank, Alan; Reed, Bryan; Schmerge, John F.; Siwick, Bradley J.; Stuart, Brent C.; Weber, Peter M.

    2005-01-01

    The use of pump-probe experiments to study complex transient events has been an area of significant interest in materials science, biology, and chemistry. While the emphasis has been on laser pump with laser probe and laser pump with x-ray probe experiments, there is a significant and growing interest in using electrons as probes. Early experiments used electrons for gas-phase diffraction of photostimulated chemical reactions. More recently, scientists are beginning to explore phenomena in the solid state such as phase transformations, twinning, solid-state chemical reactions, radiation damage, and shock propagation. This review focuses on the emerging area of ultrafast electron microscopy (UEM), which comprises ultrafast electron diffraction (UED) and dynamic transmission electron microscopy (DTEM). The topics that are treated include the following: (1) The physics of electrons as an ultrafast probe. This encompasses the propagation dynamics of the electrons (space-charge effect, Child's law, Boersch effect) and extends to relativistic effects. (2) The anatomy of UED and DTEM instruments. This includes discussions of the photoactivated electron gun (also known as photogun or photoelectron gun) at conventional energies (60-200 keV) and extends to MeV beams generated by rf guns. Another critical aspect of the systems is the electron detector. Charge-coupled device cameras and microchannel-plate-based cameras are compared and contrasted. The effect of various physical phenomena on detective quantum efficiency is discussed. (3) Practical aspects of operation. This includes determination of time zero, measurement of pulse-length, and strategies for pulse compression. (4) Current and potential applications in materials science, biology, and chemistry. UEM has the potential to make a significant impact in future science and technology. Understanding of reaction pathways of complex transient phenomena in materials science, biology, and chemistry will provide fundamental

  7. A feasibility study for producing an egg matrix candidate reference material for the polyether ionophore salinomycin.

    Science.gov (United States)

    Ferreira, Rosana Gomes; Monteiro, Mychelle Alves; Pereira, Mararlene Ulberg; da Costa, Rafaela Pinto; Spisso, Bernardete Ferraz; Calado, Veronica

    2016-08-01

    The aim of this work was to study the feasibility of producing an egg matrix candidate reference material for salinomycin. Preservation techniques investigated were freeze-drying and spray drying dehydration. Homogeneity and stability studies of the produced batches were conducted according to ISO Guides 34 and 35. The results showed that all produced batches were homogeneous and both freeze-drying and spray drying techniques were suitable for matrix dehydrating, ensuring the material stability. In order to preserve the material integrity, it must be transported within the temperature range of -20 up to 25°C. The results constitute an important step towards the development of an egg matrix reference material for salinomycin is possible. Copyright © 2016 Elsevier B.V. All rights reserved.

  8. Evaluation of botanical reference materials for the determination of vanadium in biological samples

    International Nuclear Information System (INIS)

    Heydorn, K.; Damsgaard, E.

    1982-01-01

    Three botanical reference materials prepared by the National Bureau of Standards have been studied by neutron activation analysis to evaluate their suitability with respect to the determination of vanadium in biological samples. Various decomposition methods were applied in connection with chemical or radiochemical separations, and results for vanadium were compared with those found by purely instrumental neutron activation analysis. Significantly lower results indicate losses or incomplete dissolution, which makes SRM 1575 Pine Needles and SRM 1573 Tomato Leaves less satisfactory than SRM 1570 Spinach. A reference value of 1.15 mg/kg of this material is recommended, based on results from 3 different methods. All three materials are preferable to SRM 1571 Orchard Leaves, while Bowen's Kale remains the material of choice because of its lower concentration. (author)

  9. Molecular and nanoscale materials and devices in electronics.

    Science.gov (United States)

    Fu, Lei; Cao, Lingchao; Liu, Yunqi; Zhu, Daoben

    2004-12-13

    Over the past several years, there have been many significant advances toward the realization of electronic computers integrated on the molecular scale and a much greater understanding of the types of materials that will be useful in molecular devices and their properties. It was demonstrated that individual molecules could serve as incomprehensibly tiny switch and wire one million times smaller than those on conventional silicon microchip. This has resulted very recently in the assembly and demonstration of tiny computer logic circuits built from such molecular scale devices. The purpose of this review is to provide a general introduction to molecular and nanoscale materials and devices in electronics.

  10. Application of electron and Bremsstrahlung beams for composite materials processing

    International Nuclear Information System (INIS)

    Zalyubovsky, I.I.; Avilov, A.M.; Popov, G.F.; Rudychev, V.G.

    1998-01-01

    In Kharkiv University the radiation process of obtaining composite polymer materials, CPM, with high strength properties and corrosion resistance was studied. CPM are manufactured by vacuum impregnating capillary-porous materials with synthetic monomers and oligomers or by molding granular waste and resins which are further treated by relativistic electron or Bremsstrahlung beam. Such radiation treatment yields new CPM in which capillary-porous structure acting as reinforcement is filled with polymer. The results of the applied research with industrial electron accelerator in the field of thick CPM formation are presented

  11. Materials Meets Concepts in Molecule-Based Electronics

    KAUST Repository

    Ortmann, Frank

    2014-10-14

    In this contribution, molecular materials are highlighted as an important topic in the diverse field of condensed matter physics, with focus on their particular electronic and transport properties. A better understanding of their performance in various applications and devices demands for an extension of basic theoretical approaches to describe charge transport in molecular materials, including the accurate description of electron-phonon coupling. Starting with the simplest case of a molecular junction and moving on to larger aggregates of bulk organic semiconductors, charge-transport regimes from ballistic motion to incoherent hopping, which are frequently encountered in molecular systems under respective conditions, are discussed. Transport features of specific materials are described through ab initio material parameters whose determination is addressed. © 2014 Wiley-VCH Verlag GmbH & Co. KGaA.

  12. Xyce parallel electronic simulator reference guide, Version 6.0.1.

    Energy Technology Data Exchange (ETDEWEB)

    Keiter, Eric R; Mei, Ting; Russo, Thomas V.; Schiek, Richard Louis; Thornquist, Heidi K.; Verley, Jason C.; Fixel, Deborah A.; Coffey, Todd S; Pawlowski, Roger P; Warrender, Christina E.; Baur, David Gregory.

    2014-01-01

    This document is a reference guide to the Xyce Parallel Electronic Simulator, and is a companion document to the Xyce Users Guide [1] . The focus of this document is (to the extent possible) exhaustively list device parameters, solver options, parser options, and other usage details of Xyce. This document is not intended to be a tutorial. Users who are new to circuit simulation are better served by the Xyce Users Guide [1] .

  13. Secondary Electron Emission Yields from PEP-II Accelerator Materials

    International Nuclear Information System (INIS)

    Kirby, Robert E.

    2000-01-01

    The PEP-II B-Factory at SLAC operates with aluminum alloy and copper vacuum chambers, having design positron and electron beam currents of 2 and 1 A, respectively. Titanium nitride coating of the aluminum vacuum chamber in the arcs of the positron ring is needed in order to reduce undesirable electron-cloud effects. The total secondary electron emission yield of TiN-coated aluminum alloy has been measured after samples of beam chamber material were exposed to air and again after electron-beam bombardment, as a function of incident electron beam angle and energy. The results may be used to simulate and better understand electron-cloud effects under actual operating conditions. We also present yield measurements for other accelerator materials because new surface effects are expected to arise as beam currents increase. Copper, in particular, is growing in popularity for its good thermal conductivity and self-radiation-shielding properties. The effect of electron bombardment, ''conditioning'', on the yield of TiN and copper is shown

  14. Present status and future plans of the study for preparation of Pu reference materials

    International Nuclear Information System (INIS)

    Sumi, Mika; Kageyama, Tomio; Suzuki, Toru

    2007-01-01

    All accountancy analysis at the Plutonium Fuel Development Center of JAEA is performed by isotope dilution mass spectrometry with well-characterized standard materials. Though Pu reference materials has been supplied from foreign country, importing those Pu materials is gradually becoming more difficult and may be almost impossible to import them in future. Thus, in order to establish the capability and expertise for the preparation of Pu reference materials, JAEA has started collaborative work with NBL who has high skills for preparing and supplying nuclear reference materials for long periods. One of the targets of this collaboration is preparation of standard material for IDMS (LSD spike). MOX powder which has been stored in JAEA was dissolved and Purified to obtain Pu solution. A small portion of the Purified solution was transported to NBL for analysis. LSD spike will be prepared from this Pu solution and then validation analysis and performance test including stability test will be performed with NBL and JAEA. This report presents status and future plans for the collaboration work. (author)

  15. Preparation and certification of a uranium isotope certified reference material JAERI-U5

    International Nuclear Information System (INIS)

    Tamura, Shuzo; Hashitani, Hiroshi

    1982-06-01

    The Committee on Analytical Chemistry of Nuclear Fuels and Reactor Materials, JAERI had planned to prepare a new reference material, JAERI-U5 for uranium isotopic measurement since 1978. The reference material is composed of 6 samples of different enrichment in the range of 0.2 to 4.5 wt. percents of 235 U. The preparation includes dissolution of raw materials, blending of solutions, precipitation of ammonium diuranate, drying and ignition to U 3 O 8 . A mass-spectrometric collaborative analysis was carried out by well-trained two laboratories in this country, JAERI and PNC. The certified values were decided from the result of the collaborative work. As the measurements were based on NBS SRM's, JAERI-U5 should be called tertiary standard. The materials are packed in bottles of low-potassium-content glass for a possible use in non-destructive gamma-rays spectrometry. The reference material has been distributing from JAERI with a price of yen 140,000 per set (6 samples of 2 g of each) since 1979. (author)

  16. Reference material for radionuclides in sediment IAEA-384 (Fangataufa Lagoon sediment)

    DEFF Research Database (Denmark)

    Povinec, P.P.; Pham, M.K.; Sanchez-Cabeza, J.A.

    2007-01-01

    A reference material designed for the determination of anthropogenic and natural radionuclides in sediment, IAEA-384 (Fangataufa Lagoon sediment), is described and the results of certification are presented. The material has been certified for 8 radionuclides (K-40, Co-60, Eu-155, Th-230, U-238, ...... management of radioanalytical laboratories engaged in the analysis of radionuclides in the environment, as well as for the development and validation of analytical methods and for training purposes. The material is available from IAEA in 100 g units.......A reference material designed for the determination of anthropogenic and natural radionuclides in sediment, IAEA-384 (Fangataufa Lagoon sediment), is described and the results of certification are presented. The material has been certified for 8 radionuclides (K-40, Co-60, Eu-155, Th-230, U-238, Pu......-238, Pu239+240 and Am-241). Information values are given for 12 radionuclides (Sr-90, Cs-137, Pb-210 (Po-210), Ra-226, Ra-228, Th-232, U-234, U-235, Pu-239, Pu-240 and Pu-241). Less reported radionuclides include Th-228, U-236, Np-239 and Pu-242. The reference material may be used for quality...

  17. Soft Active Materials for Actuation, Sensing, and Electronics

    OpenAIRE

    Kramer, Rebecca Krone

    2012-01-01

    Future generations of robots, electronics, and assistive medical devices will include systems that are soft and elastically deformable, allowing them to adapt their morphology in unstructured environments. This will require soft active materials for actuation, circuitry, and sensing of deformation and contact pressure. The emerging field of soft robotics utilizes these soft active materials to mimic the inherent compliance of natural soft-bodied systems. As the elasticity of robot components ...

  18. IAEA Reference Materials for Quality Assurance: A Study in the Quality Control of Marine Radioactivity

    International Nuclear Information System (INIS)

    Pham Mai Khanh; Bartocci, J.; Gastaud, J.; Nies, H.; Vasileva, E.; Betti, M.; Chamizo, E.; Gomez-Guzman, J.-M.

    2013-01-01

    The IAEA's Marine Environment Laboratories has assisted laboratories in Analytical Quality Control Services (AQCS) for the analysis of radionuclides in the marine environment since the early seventies. The AQCS programme, now named Reference Products for Environment and Trade, is recognized as an essential component of quality assurance and control and for the development and validation of analytical methods, through its worldwide and regional interlaboratory comparisons and the provision of reference methods and Reference Materials/Certified Reference Materials (RMs/CRMs). A total of 49 interlaboratory exercises were organized and 42 RMs/CRMs were produced for marine radioactivity studies. Different techniques such as radiometric methods with X ray, gamma spectrometry, alpha spectrometry, beta counter, liquid scintillation counter as well as mass spectrometry (ICP-MS, AMS, TIMS) are applied for the characterization during certification process. An overview of prepared Certified Reference Materials (CRMs) for radionuclides in marine matrices will be presented as well as lessons learned from interlaboratory comparisons (ICs) and Proficiency Tests (PTs). A characterization of a new CRM for radionuclides in IAEA-446, Baltic Sea seaweed (Fucus vesiculosus), as well as a specific case of using Accelerator Mass Spectrometry (AMS) technique to characterize I-129 in sea water (IAEA-418) and seaweed sample (IAEA-446), will be discussed. Available RMs/CRMs are listed and can be ordered and purchased through the IAEA website http://nucleus.iaea.org/rpst/. (author)

  19. IAEA Reference Materials for Quality Assurance: A Study in the Quality Control of Marine Radioactivity

    Energy Technology Data Exchange (ETDEWEB)

    Khanh, Pham Mai; Bartocci, J.; Gastaud, J.; Nies, H.; Vasileva, E.; Betti, M. [International Atomic Energy Agency, Environment Laboratory (Monaco); Chamizo, E.; Gomez-Guzman, J. -M. [Centro Nacional de Aceleradores, Seville (Spain)

    2013-07-15

    The IAEA's Marine Environment Laboratories has assisted laboratories in Analytical Quality Control Services (AQCS) for the analysis of radionuclides in the marine environment since the early seventies. The AQCS programme, now named Reference Products for Environment and Trade, is recognized as an essential component of quality assurance and control and for the development and validation of analytical methods, through its worldwide and regional interlaboratory comparisons and the provision of reference methods and Reference Materials/Certified Reference Materials (RMs/CRMs). A total of 49 interlaboratory exercises were organized and 42 RMs/CRMs were produced for marine radioactivity studies. Different techniques such as radiometric methods with X ray, gamma spectrometry, alpha spectrometry, beta counter, liquid scintillation counter as well as mass spectrometry (ICP-MS, AMS, TIMS) are applied for the characterization during certification process. An overview of prepared Certified Reference Materials (CRMs) for radionuclides in marine matrices will be presented as well as lessons learned from interlaboratory comparisons (ICs) and Proficiency Tests (PTs). A characterization of a new CRM for radionuclides in IAEA-446, Baltic Sea seaweed (Fucus vesiculosus), as well as a specific case of using Accelerator Mass Spectrometry (AMS) technique to characterize I-129 in sea water (IAEA-418) and seaweed sample (IAEA-446), will be discussed. Available RMs/CRMs are listed and can be ordered and purchased through the IAEA website http://nucleus.iaea.org/rpst/. (author)

  20. Normalization Methods and Selection Strategies for Reference Materials in Stable Isotope Analyses - Review

    International Nuclear Information System (INIS)

    Skrzypek, G.; Sadler, R.; Paul, D.; Forizs, I.

    2011-01-01

    A stable isotope analyst has to make a number of important decisions regarding how to best determine the 'true' stable isotope composition of analysed samples in reference to an international scale. It has to be decided which reference materials should be used, the number of reference materials and how many repetitions of each standard is most appropriate for a desired level of precision, and what normalization procedure should be selected. In this paper we summarise what is known about propagation of uncertainties associated with normalization procedures and propagation of uncertainties associated with reference materials used as anchors for the determination of 'true' values for δ''1''3C and δ''1''8O. Normalization methods Several normalization methods transforming the 'raw' value obtained from mass spectrometers to one of the internationally recognized scales has been developed. However, as summarised by Paul et al. different normalization transforms alone may lead to inconsistencies between laboratories. The most common normalization procedures are: single-point anchoring (versus working gas and certified reference standard), modified single-point normalization, linear shift between the measured and the true isotopic composition of two certified reference standards, two-point and multipoint linear normalization methods. The accuracy of these various normalization methods has been compared by using analytical laboratory data by Paul et al., with the single-point and normalization versus tank calibrations resulting in the largest normalization errors, and that also exceed the analytical uncertainty recommended for δ 13 C. The normalization error depends greatly on the relative differences between the stable isotope composition of the reference material and the sample. On the other hand, the normalization methods using two or more certified reference standards produces a smaller normalization error, if the reference materials are bracketing the whole range of

  1. IRMM Certified Reference Materials and k0-NAA: an important role for the future

    International Nuclear Information System (INIS)

    Robouch, P.; Arana, G.; Pauwels, J.; Pomm, S.

    1998-01-01

    The k 0 -Neutron Activation Analysis method was introduced at the Institute for Reference Materials and Measurements (IRMM) and the Belgian nuclear research centre (SCK CEN) in 1994. This analytical technique is routinely used at IRMM for the production control, homogeneity and stability tests and/or for certification of metallic, biological and environmental reference materials. The successful implementation of k 0 -NAA was proven at several certification exercises - such as ISS Antarctic Sediment, BCR Mussel Tissue and BCR Bovine Liver, SMU Bovine Blood - where all our results were accepted for certification. Responding to regulatory and/or scientific demands, IRMM is collaborating with national institutes to develop new high quality reference materials: (i) in the field of Neutron dosimetry: high purity nickel, Al-Ag or Zr-Au-Lu alloys; (ii) for environmental and industrial monitoring: Antarctic krill, doped plastics or catalytic converters; (iii) synthetic multi-element standard for the accreditation of k 0 -NAA laboratories. Far from being exhaustive, this list highlights the important role that k 0 -NAA will play in the certification of reference materials in the years 2000. (author)

  2. Analysis of FDA in-house food reference materials with anticoincidence INAA

    International Nuclear Information System (INIS)

    Anderson, D.L.; Cunningham, W.C.

    2013-01-01

    In-house reference material (IRM) cocoa powder (CCP) has been in use at US Food and Drug Administration laboratories for about 15 years. A single lot of commercial material was originally characterized for 32 elements by several laboratories and five techniques. A unique approach for basis weight determination based upon ambient relative humidity was developed for CCP, eliminating the need for dry weight determinations. The CCP Reference Sheet is updated by incorporating new results approximately every 5 years. The last update occurred in 2006. As part of an effort to revalidate and update values for CCP, anticoincidence instrumental neutron activation analysis (INAA) was used to determine mass fractions for 16 of the originally characterized elements, as well as to provide information on 16 other elements. Results were in very good agreement with 2006 Reference Sheet values. A new candidate IRM, fresh-frozen swordfish (FFSF) powder, was produced by adding inorganic As, Cd, Cr, Hg, Pb, Sb, and Se to liquid nitrogen-frozen commercial swordfish filets which were then homogenized. Portions of FFSF were analyzed by INAA to provide mass fraction and homogeneity information for As, Cd, Cr, Hg, Sb, and Se as well as for eight other elements occurring naturally in the material. Non-homogeneities were ≤2.5 % for As, Br, Cd, and Cs, and ≤1.8 % for Cr, Hg, Rb, Sb, and Se. Certified reference materials DORM-3 Fish Protein powder and fresh-frozen SRM 1947 Lake Michigan Fish Tissue were analyzed as controls. (author)

  3. Compilation of elemental concentration data for NBS Biological and Environmental Standard Reference Materials

    International Nuclear Information System (INIS)

    Gladney, E.S.

    1980-07-01

    Concentration data on up to 76 elementals in 19 NBS Standard Reference Materials have been collected from 325 journal articles and technical reports. These data are summarized into mean +- one standard deviation values and compared with available data from NBS and other review articles. Data are presented on the analytical procedures employed and all raw data are presented in appendixes

  4. Speciation of dimethylarsinyl-riboside derivatives (arsenosugars) in marine reference materials by HPLC-ICP-MS

    DEFF Research Database (Denmark)

    Larsen, Erik Huusfeldt

    1995-01-01

    (cf. Table 2) were present in shellfish certified reference materials (CRMs) and in a lobster hepatopancreas CRM. The concentration of the two arsenosugars in the shellfish samples amounts to 18% of the total arsenic as compared to arsenobetaine at 9–13% and dimethylarsinate at 4–9% of the total...

  5. An independent accurate reference method for the determination of chromium in biological materials

    NARCIS (Netherlands)

    Lagerwaard, A.; Woittiez, J.R.W.; de Goeij, J.J.M.

    1994-01-01

    A method for the determination of Cr in biological materials with high accuracy is reported for use as an independent reference method. It is based on radiochemical neutron activation analysis (RNAA) in combination with an individual yield determination based on the online yield principle. A

  6. Doorways III: Teacher Reference Materials. On School-Related Gender-Based Violence Prevention and Response

    Science.gov (United States)

    US Agency for International Development, 2009

    2009-01-01

    The Doorways training program was designed by the U.S. Agency for International Development (USAID)-funded Safe Schools Program (Safe Schools) to enable teachers, community members and students to prevent and respond to school-related gender-based violence (SRGBV). This booklet, "Doorways III: Teacher Reference Materials on School-Related…

  7. Instrumental neutron and photon activation analyses of selected geochemical reference materials

    Czech Academy of Sciences Publication Activity Database

    Mizera, Jiří; Řanda, Zdeněk

    2010-01-01

    Roč. 284, č. 1 (2010), s. 157-163 ISSN 0236-5731 R&D Projects: GA AV ČR IAA300130706 Institutional research plan: CEZ:AV0Z10480505 Keywords : neutron activation analysis * photon activation analysis * geochemical reference materials Subject RIV: BG - Nuclear, Atomic and Molecular Physics, Colliders Impact factor: 0.777, year: 2010

  8. Instrumental neutron and photon activation analyses of selected geochemical reference materials

    Czech Academy of Sciences Publication Activity Database

    Mizera, Jiří; Řanda, Z.

    2010-01-01

    Roč. 284, č. 1 (2010), s. 157-163 ISSN 0236-5731 Institutional research plan: CEZ:AV0Z30460519 Keywords : neutron activation analysis * photon activation analysis * geochemical reference materials Subject RIV: BG - Nuclear, Atomic and Molecular Physics, Colliders OBOR OECD: Analytical chemistry Impact factor: 0.777, year: 2010

  9. Reference material certification of chinese cabbage composition for selenium, nitrogen, phosphorus and potassium content

    Directory of Open Access Journals (Sweden)

    D. A. Chupakhin

    2016-01-01

    Full Text Available Rationale. The reference material of composition with the established metrological characteristics including a certified value and an expanded uncertainty is necessary to ensure an effective accuracy and precision control of results of element composition determination in food ingredients and products. This paper represents the development of a reference material of food crop composition for selenium, nitrogen, phosphorus and potassium content. Methods. To identify the selenium the hybrid atomic absorption method was used, to identify the nitrogen and phosphorus the photometric method was used, to determine the potassium flame-photometric method was used. When determining the metrological characteristics of the reference material the Russian national instructions and recommendations MI 3174-2009 and P 50.2.058-2007 were applied. Results. Based on the research findings the reference material of Chinese cabbage composition with a certified value and an expanded uncertainty was developed: for selenium 0.044 ± 0.017 mg/kg; for nitrogen 4.09 ± 0.27 %; for phosphorus 0.69 ± 0.14 %; for potassium 2.87 ± 0.22 %.

  10. Determination of trace elements in standard reference materials by the ko-standardization method

    International Nuclear Information System (INIS)

    Smodis, B.; Jacimovic, R.; Stegnar, P.; Jovanovic, S.

    1990-01-01

    The k o -standardization method is suitable for routine multielement determinations by reactor neutron activation analysis (NAA). Investigation of NIST standard reference materials SRM 1571 Orchard Leaves, SRM 1572 Citrus leaves, and SRM 1573 Tomato Leaves showed the systematic error of 12 certified elements determined to be less than 8%. Thirty-four elements were determined in NIST proposed SRM 1515 Apple Leaves

  11. Intercomparison of enriched stable isotope reference materials for medical and biological studies

    International Nuclear Information System (INIS)

    Parr, R.M.; Clements, S.A.

    1991-01-01

    This report summarizes the results of an intercomparison exercise organized by the IAEA during the latter part of 1988 and 1989. Data are presented for 13 different kinds of enriched stable isotope reference material containing 2 H, 13 C, 15 N and 18 O. Results were submitted by forty participants in twenty countries. 2 refs, 13 figs, 18 tabs

  12. Analysis of marine sediment and lobster hepatopancreas reference materials by instrumental photon activation

    International Nuclear Information System (INIS)

    Landsberger, S.; Davidson, W.F.

    1985-01-01

    By use of instrumental photon activation analysis, twelve trace (As, Ba, Cr, Co, Mn, Ni, Pb, Sb, Sr, U, Zn, and Zr) and eight minor (C, Na, Mg, Co, K, Ca, Tl, and Fe) elements were determined in a certified marine sediment standard reference material as well as eight trace (Mn, Ni, Cu, Zn, As, Sr, Cd, and Pb) and four minor (Na, Mg, Cl, and Ca) elements in a certified marine tissue (lobster hepatopancreas) standard reference material. The precision and accuracy of the present results when compared to the accepted values clearly demonstrate the reliability of this nondestructive technique and its applicability to marine environmental or marine geochemical studies. 24 references, 4 figures, 3 tables

  13. Electron fluence correction factors for various materials in clinical electron beams

    International Nuclear Information System (INIS)

    Olivares, M.; Blois, F. de; Podgorsak, E.B.; Seuntjens, J.P.

    2001-01-01

    Relative to solid water, electron fluence correction factors at the depth of dose maximum in bone, lung, aluminum, and copper for nominal electron beam energies of 9 MeV and 15 MeV of the Clinac 18 accelerator have been determined experimentally and by Monte Carlo calculation. Thermoluminescent dosimeters were used to measure depth doses in these materials. The measured relative dose at d max in the various materials versus that of solid water, when irradiated with the same number of monitor units, has been used to calculate the ratio of electron fluence for the various materials to that of solid water. The beams of the Clinac 18 were fully characterized using the EGS4/BEAM system. EGSnrc with the relativistic spin option turned on was used to optimize the primary electron energy at the exit window, and to calculate depth doses in the five phantom materials using the optimized phase-space data. Normalizing all depth doses to the dose maximum in solid water stopping power ratio corrected, measured depth doses and calculated depth doses differ by less than ±1% at the depth of dose maximum and by less than 4% elsewhere. Monte Carlo calculated ratios of doses in each material to dose in LiF were used to convert the TLD measurements at the dose maximum into dose at the center of the TLD in the phantom material. Fluence perturbation correction factors for a LiF TLD at the depth of dose maximum deduced from these calculations amount to less than 1% for 0.15 mm thick TLDs in low Z materials and are between 1% and 3% for TLDs in Al and Cu phantoms. Electron fluence ratios of the studied materials relative to solid water vary between 0.83±0.01 and 1.55±0.02 for materials varying in density from 0.27 g/cm3 (lung) to 8.96 g/cm3 (Cu). The difference in electron fluence ratios derived from measurements and calculations ranges from -1.6% to +0.2% at 9 MeV and from -1.9% to +0.2% at 15 MeV and is not significant at the 1σ level. Excluding the data for Cu, electron fluence

  14. Certification of a plutonium dioxide reference material for elemental analyses (EC-NRM 210)

    International Nuclear Information System (INIS)

    Le Duigou, Y.

    1990-01-01

    A new EC plutonium reference material is made available in the form of 5g samples of plutonium dioxide powder. Before weighing the material must be calcined at 1 250 0 C for two hours. The plutonium content (880.26 ± 0.44) g.kg -1 has been derived from plutonium measurements performed by three different laboratories each applying a different oxydo-reductive method. The results of the plutonium measurement, the statistical evaluation of the uncertainty of the plutonium content together with information on the impurities present in the material are given in the report

  15. Highlighting material structure with transmission electron diffraction correlation coefficient maps.

    Science.gov (United States)

    Kiss, Ákos K; Rauch, Edgar F; Lábár, János L

    2016-04-01

    Correlation coefficient maps are constructed by computing the differences between neighboring diffraction patterns collected in a transmission electron microscope in scanning mode. The maps are shown to highlight material structural features like grain boundaries, second phase particles or dislocations. The inclination of the inner crystal interfaces are directly deduced from the resulting contrast. Copyright © 2016 Elsevier B.V. All rights reserved.

  16. Decontamination of drug vegetative raw material by relativistic electron beam

    International Nuclear Information System (INIS)

    Gorbanyuk, A.G.; Dikiy, I.L.; Yegorov, A.M.; Linnik, A.F.; Uskov, V.V.

    2004-01-01

    The new technology of decontamination of drug vegetative raw material and medical products is proposed. Advantages of use of relativistic beams in a range of electron energies from 0.5 MeV to 5 MeV for these purposes are shown in comparison with X-radiation of energy from 80 keV to 1 MeV

  17. Electron Charged Graphite-based Hydrogen Storage Material

    Energy Technology Data Exchange (ETDEWEB)

    Dr. Chinbay Q. Fan; D Manager

    2012-03-14

    The electron-charge effects have been demonstrated to enhance hydrogen storage capacity using materials which have inherent hydrogen storage capacities. A charge control agent (CCA) or a charge transfer agent (CTA) was applied to the hydrogen storage material to reduce internal discharge between particles in a Sievert volumetric test device. GTI has tested the device under (1) electrostatic charge mode; (2) ultra-capacitor mode; and (3) metal-hydride mode. GTI has also analyzed the charge distribution on storage materials. The charge control agent and charge transfer agent are needed to prevent internal charge leaks so that the hydrogen atoms can stay on the storage material. GTI has analyzed the hydrogen fueling tank structure, which contains an air or liquid heat exchange framework. The cooling structure is needed for hydrogen fueling/releasing. We found that the cooling structure could be used as electron-charged electrodes, which will exhibit a very uniform charge distribution (because the cooling system needs to remove heat uniformly). Therefore, the electron-charge concept does not have any burden of cost and weight for the hydrogen storage tank system. The energy consumption for the electron-charge enhancement method is quite low or omitted for electrostatic mode and ultra-capacitor mode in comparison of other hydrogen storage methods; however, it could be high for the battery mode.

  18. Advanced electrical and electronics materials processes and applications

    CERN Document Server

    Gupta, K M

    2015-01-01

    This comprehensive and unique book is intended to cover the vast and fast-growing field of electrical and electronic materials and their engineering in accordance with modern developments.   Basic and pre-requisite information has been included for easy transition to more complex topics. Latest developments in various fields of materials and their sciences/engineering, processing and applications have been included. Latest topics like PLZT, vacuum as insulator, fiber-optics, high temperature superconductors, smart materials, ferromagnetic semiconductors etc. are covered. Illustrations and exa

  19. Electronic fitness function for screening semiconductors as thermoelectric materials

    International Nuclear Information System (INIS)

    Xing, Guangzong; Sun, Jifeng; Li, Yuwei; Fan, Xiaofeng

    2017-01-01

    Here, we introduce a simple but efficient electronic fitness function (EFF) that describes the electronic aspect of the thermoelectric performance. This EFF finds materials that overcome the inverse relationship between σ and S based on the complexity of the electronic structures regardless of specific origin (e.g., isosurface corrugation, valley degeneracy, heavy-light bands mixture, valley anisotropy or reduced dimensionality). This function is well suited for application in high throughput screening. We applied this function to 75 different thermoelectric and potential thermoelectric materials including full- and half-Heuslers, binary semiconductors, and Zintl phases. We find an efficient screening using this transport function. The EFF identifies known high-performance p- and n-type Zintl phases and half-Heuslers. In addition, we find some previously unstudied phases with superior EFF.

  20. Certification of a meat reference material based on a collaborative study

    Directory of Open Access Journals (Sweden)

    Claudia Marcela Salazar Arzate

    2013-01-01

    Full Text Available Through a collaborative project, comparison studies were carried out to improve measurement capabilities of participating laboratories, supporting them to produce, characterize and distribute reference materials in the food sector. The project was planned in four annual stages (milk, water, meat and grains. The third stage aimed specifically to quantify and certify the nutritional content of the parameters (nitrogen, fat, sodium and potassium of a batch candidate as Certified Reference Material (CRM of canned beef. This study was conducted in collaboration between several National Metrology Institutes (NMIs and/or collaborating laboratories, which, once identified the possible causes of variability or bias in the measurements, as well as the opportunities of improvement, achieved the certification of the material beef. The CRM was distributed among the participants to cover the needs of the food industry of meat products and testing laboratories in their respective countries.

  1. Aluminium-gold reference material for the k0-standardisation of neutron activation analysis

    International Nuclear Information System (INIS)

    Ingelbrecht, C.; Peetermans, F.; Corte, F. de; Wispelaere, A. de; Vandecasteele, C.; Courtijn, E.; Hondt, P. d'

    1991-01-01

    Gold is an excellent comparator material for the k 0 -standardisation of neutron activation analysis because of its convenient and well defined nuclear properties. The most suitable form for a reference material is a dilute aluminium-gold alloy, for which the self-shielding effect for neutrons is small. Castings of composition Al-0.1 wt.% Au were prepared by crucible-less levitation melting, which gives close control of ingot composition with minimal contamination of the melt. The alloy composition was checked using induction-coupled plasma source emission spectrometry. The homogeneity of the alloy was measured by neutron activation analysis and a relative standard deviation of the gold content of 0.30% was found (10 mg samples). Metallography revealed a homogeneous distribution of AuAl 2 particles. The alloy was certified as Reference Materials CBNM-530, with certified gold mass fraction 0.100±0.002 wt.%. (orig.)

  2. Ceramic materials on perovskite-type structure for electronic applications

    International Nuclear Information System (INIS)

    Surowiak, Z.

    2003-01-01

    Ceramic materials exhibiting the perovskite-type structure constitute among others, resource base for many fields of widely understood electronics (i.e., piezoelectronics, accustoelectronics, optoelectronics, computer science, tele- and radioelectronics etc.). Most often they are used for fabrication of different type sensors (detectors), transducers, ferroelectric memories, limiters of the electronic current intensity, etc., and hence they are numbered among so-called intelligent materials. Prototype structure of this group of materials is the structure of the mineral called perovskite (CaTiO 3 ). By means of right choice of the chemical composition of ABO 3 and deforming the regular perovskite structure (m3m) more than 5000 different chemical compounds and solid solutions exhibiting the perovskite-type structure have been fabricated. The concept of perovskite functional ceramics among often things ferroelectric ceramics, pyroelectric ceramics, piezoelectric ceramics, electrostrictive ceramics, posistor ceramics, superconductive ceramics and ferromagnetic ceramics. New possibilities of application of the perovskite-type ceramics are opened by nanotechnology. (author)

  3. Low-energy electron inelastic mean free path in materials

    Energy Technology Data Exchange (ETDEWEB)

    Nguyen-Truong, Hieu T., E-mail: nguyentruongthanhhieu@tdt.edu.vn [Theoretical Physics Research Group & Faculty of Applied Sciences, Ton Duc Thang University, Ho Chi Minh City 756636 (Viet Nam)

    2016-04-25

    We show that the dielectric approach can determine electron inelastic mean free paths in materials with an accuracy equivalent to those from first-principle calculations in the GW approximation of many-body theory. The present approach is an alternative for calculating the hot-electron lifetime, which is an important quantity in ultrafast electron dynamics. This approach, applied here to solid copper for electron energies below 100 eV, yields results in agreement with experimental data from time-resolved two-photon photoemission, angle-resolved photoelectron spectroscopy, and X-ray absorption fine structure measurements in the energy ranges 2–3.5, 10–15, and 60–100 eV, respectively.

  4. Development of new reference materials for the determination of cadmium, chromium, mercury and lead in polycarbonate

    International Nuclear Information System (INIS)

    Lee, Kil Jae; Lee, Yeo Jin; Choi, Young Rak; Kim, Jeong Sook; Kim, Youn Sung; Heo, Soo Bong

    2013-01-01

    Highlights: ► RMs for the determination of Cd, Cr, Hg and Pb in polycarbonate were developed. ► Double ID-ICP-MS technique was used for characterization of candidate RMs. ► The certified values for the elements ranged from 51.7 to 1133 mg kg −1 . ► The relative expanded uncertainties were shown to be less than 5.4%. ► New RMs were found to be suitable for the RoHS compliant tests. - Abstract: Reference materials for quantitative determination of Cd, Cr, Hg and Pb in polycarbonate were developed. Reference materials with two concentration level of elements were prepared by adding appropriate amounts of chemicals to a blank polycarbonate base material. It was shown that ten bottles with triplicate analysis are enough to demonstrate the homogeneity of these candidate reference materials. The statistical results also showed no significant trends in both short-term stability test for four weeks and long-term stability test for twelve months. The certification of the four elements was carried out by isotope-dilution-inductively coupled plasma mass spectrometry (ID-ICP-MS) with microwave-assisted digestion. Certification of candidate reference materials in a single laboratory was confirmed with interlaboratory comparison participated by a certain number of well-recognized testing laboratories in Korea. The certified values and expanded uncertainties (k = 2) for the candidate reference material with low level and the one with high level were (51.7 ± 2.1) mg kg −1 Cd, (103.8 ± 2.9) mg kg −1 Cd, (98.8 ± 4.5) mg kg −1 Cr, (1004 ± 49.8) mg kg −1 Cr, (107.4 ± 4.6) mg kg −1 Hg, (1133 ± 50.7) mg kg −1 Hg, (94.8 ± 3.7) mg kg −1 Pb and (988.4 ± 53.6) mg kg −1 Pb, respectively. The reference materials developed in this study demonstrated their suitability for the quality assurance in Cd, Cr, Hg and Pb analysis for the implementation of RoHS Directive.

  5. Reference methods and materials. A programme of support for regional and global marine pollution assessments

    International Nuclear Information System (INIS)

    1990-01-01

    This document describes a programme of comprehensive support for regional and global marine pollution assessments developed by the United Nations Environment Programme (UNEP) in cooperation with the International Atomic Energy Agency (IAEA) and the Intergovernmental Oceanographic Commission (IOC) and with the collaboration of a number of other United Nations Specialized agencies including the Food and Agriculture Organisation (FAO), the World Meteorological Organisation (WMO), the World Health Organisation (WHO) and the International Maritime Organisation (IMO). Two of the principle components of this programme, Reference Methods and Reference materials are given special attention in this document and a full Reference Method catalogue is included, giving details of over 80 methods currently available or in an advanced stage of preparation and testing. It is important that these methods are seen as a functional component of a much wider strategy necessary for assuring good quality and intercomparable data for regional and global pollution monitoring and the user is encouraged to read this document carefully before employing Reference Methods and Reference Materials in his/her laboratory. 3 figs

  6. U. S. programs on reference and advanced cladding/duct materials

    International Nuclear Information System (INIS)

    Bennett, J.W.; Holmes, J.J.; Laidler, J.J.

    1977-05-01

    Two coordinated national programs are presently in place in the United States for development of reference and advanced cladding and duct alloys for near-term and long-term LMFBR applications. A number of government, industrial and university laboratories are active participants in these two ERDA-sponsored programs. The programs are administered by ERDA through a task group organization, with each task group representing a particular technical activity and the membership of the task group drawn from among the laboratories with active involvement in that activity. Technical coordination of the two programs is provided by the Hanford Engineering Development Laboratory. The National Reference Cladding and Duct Program is charged with the responsibility for development of the required technology to permit full utilization of the reference material, 20 percent cold-worked Type 316 stainless steel, in early LMFBR core applications. The current schedule calls for full evaluation of FFTF-related design base data prior to full-power operation of FFTF in early 1980, followed by a confirmation in early 1983 of reference material performance capabilities for initial-core CRBRP applications. Comprehensive evaluation of reference material performance to commercial plant goal fluence levels will be complete by 1985. The National Advanced Alloy Development Program was instituted in 1974 with the objective to develop, by 1986, advanced cladding and duct materials compatible with advanced fuel systems having peak burnup capabilities up to 150 MWD/kg and doubling times of 15 years or less. Screening of a large number of potential alloys was completed in mid-1975, and there are presently 16 candidate alloys under active investigation

  7. CETAMA contribution to safeguards and nuclear forensic analysis based on nuclear reference materials

    International Nuclear Information System (INIS)

    Roudil, D.; Rigaux, C.; Rivier, C.; Hubinois, J.C.; Aufore, L.

    2012-01-01

    Measurement quality is crucial for the safety of nuclear facilities: nuclear reference materials (CRM) and interlaboratory programs (ILC), beyond the assessment of analytical measurement quality, play an important role. In the nuclear field, the CETAMA proposes suitable scientific and technical developments, in particular the preparation and certification of CRM used either as analytical standards or as reference samples for ILCs. The growing emphasis on nuclear forensic measurements will require some re-certification of old CRMs. But the future analytical challenges of meeting nuclear fuel cycle needs and of ensuring safeguard performance improvements will also concern the future CRMs. (authors)

  8. Polycyclic aromatic hydrocarbons (PAHs) in a coal tar standard reference material - SRM 1597a updated

    Energy Technology Data Exchange (ETDEWEB)

    Wise, Stephen A.; Poster, Dianne L.; Rimmer, Catherine A.; Schubert, Patricia; Sander, Lane C.; Schantz, Michele M. [National Institute of Standards and Technology (NIST), Analytical Chemistry Division, Gaithersburg, MD (United States); Leigh, Stefan D. [National Institute of Standards and Technology (NIST), Statistical Engineering Division, Gaithersburg, MD (United States); Moessner, Stephanie [National Institute of Standards and Technology (NIST), Analytical Chemistry Division, Gaithersburg, MD (United States); GMP/Comparator Labs, Werthenstein Chemie AG, Industrie Nord, Schachen (Switzerland)

    2010-09-15

    SRM 1597 Complex Mixture of Polycyclic Aromatic Hydrocarbons from Coal Tar, originally issued in 1987, was recently reanalyzed and reissued as SRM 1597a with 34 certified, 46 reference, and 12 information concentrations (as mass fractions) for polycyclic aromatic hydrocarbons (PAHs) and polycyclic aromatic sulfur heterocycles (PASHs) including methyl-substituted PAHs and PASHs. The certified and reference concentrations (as mass fractions) were based on results of analyses of the coal tar material using multiple analytical techniques including gas chromatography/mass spectrometry on four different stationary phases and reversed-phase liquid chromatography. SRM 1597a is currently the most extensively characterized SRM for PAHs and PASHs. (orig.)

  9. Establishing the traceability of a uranyl nitrate solution to a standard reference material

    International Nuclear Information System (INIS)

    Jackson, C.H.; Clark, J.P.

    1978-01-01

    A uranyl nitrate solution for use as a Working Calibration and Test Material (WCTM) was characterized, using a statistically designed procedure to document traceability to National Bureau of Standards Reference Material (SPM-960). A Reference Calibration and Test Material (PCTM) was prepared from SRM-960 uranium metal to approximate the acid and uranium concentration of the WCTM. This solution was used in the characterization procedure. Details of preparing, handling, and packaging these solutions are covered. Two outside laboratories, each having measurement expertise using a different analytical method, were selected to measure both solutions according to the procedure for characterizing the WCTM. Two different methods were also used for the in-house characterization work. All analytical results were tested for statistical agreement before the WCTM concentration and limit of error values were calculated. A concentration value was determined with a relative limit of error (RLE) of approximately 0.03% which was better than the target RLE of 0.08%. The use of this working material eliminates the expense of using SRMs to fulfill traceability requirements for uranium measurements on this type material. Several years' supply of uranyl nitrate solution with NBS traceability was produced. The cost of this material was less than 10% of an equal quantity of SRM-960 uranium metal

  10. Grain-size effects on PIXE and INAA analysis of IAEA-336 lichen reference material

    Science.gov (United States)

    Marques, A. P.; Freitas, M. C.; Wolterbeek, H. Th.; Verburg, T. G.; De Goeij, J. J. M.

    2007-02-01

    IAEA-336 lichen certified reference material was used to compare outcomes from INAA and PIXE elemental analyses, in relationship with grain size. The IAEA material (grain size lichen reference material's particle size distribution follows a bimodal distribution, which is turning more and more monomodal after further fine sieving. Replicates of each fraction were analysed by INAA and PIXE. Results for Cl, K, Mn, Fe and Zn by both techniques were compared by application of z-values tested against the criterion ∣ z∣ limited amount of lichen material as "seen" in the PIXE analysis and the grain size distribution in the lichen material were no causes of measurable differences between the results of both techniques. However, fractionation into smaller grain sizes showed to be associated with lower element content, for Na, Cl, K, Mn and Sr even up to a factor of 2. The observed increases of the proportion of algae in the smaller grain-size fractions and the possible accumulation capacity for certain elements in the fungal part of the lichen may explain the observed phenomenon. The sieving process and consequently the discarding of part of the material have lead to a change of the properties of the original sample, namely algae/fungus percentage and elemental contents.

  11. Certification of biological reference materials: participation of the Neutron Activation Laboratory (LAN-IPEN/CNEN-SP)

    International Nuclear Information System (INIS)

    Ticianelli, Regina B.; Figueiredo, Ana Maria G.

    2007-01-01

    Analytical laboratories have as one of their important goals to demonstrate their competence allowing international acceptance and comparison of analytical data. The IPEN Neutron Activation Laboratory (LAN-IPEN) has implemented its Quality Assurance Program which comprises, among other activities, the participation in intercomparison runs. As a part of this Quality Assurance Program, LAN-IPEN has participated in interlaboratorial trials to analyze two biological candidate reference materials: INCT-CF-3 Corn Flour and INCT-SBF-4 Soya Bean Flour from the Institute of Nuclear Chemistry And Technology (Warszawa, Poland). The elements Br, Ca, Co, Cs, Fe, K, Na, Rb and Zn were analyzed in the candidate reference materials by instrumental neutron activation analysis (INAA). The performance of the laboratory was statistically evaluated in relation to the consensus values for these materials using the Z-Score test. This laboratory evaluation method has been accepted as a standard by ISO/IUPAC. In the present study, adequate Z-Score values (|Z|<2) were observed for all of the analyzed elements, confirming the accuracy of the nuclear methodology employed. The contribution of LAN-IPEN in the certification of the reference materials analyzed was very important, since the results provided were used in the statistical evaluation of the certified value. (author)

  12. Application of an electronic bulletin board, as a mechanism of coordination of actions in complex systems - reference model

    Directory of Open Access Journals (Sweden)

    Katarzyna Grzybowska

    2015-06-01

    Full Text Available Background: In her previous research, the author of this publication indicates that coordination is a dependent variable which has a great driving force and is a very unstable factor. This results in the fact that all of the actions connected with coordination have an impact on other factors of cooperation as well as the integration of the enterprises in the structures of a supply chain type structure. Material and methods:  The article has been divided into two basic parts. The first part regards the reference models in complex systems (supply chain systems. They can constitute a starting point for the modelling of target processes in the built supply chain structure. The second part presents template process models (Reference Models for selected action coordination mechanisms during enterprise cooperation. The aim of the article is the presentation the model an Electronic Bulletin Board (EBB, as a mechanism of coordination of actions in complex systems. Results: The article was prepared on the basis of literature from the researched area. The material was also prepared on the basis of interviews with practitioners. They have allowed for the preparation of template process models (Reference Models for selected action coordination methods in the supply chain. Conclusions: The result of the work is a prepared model as well as its description in the use of IDEF0. The presented model is a demonstrative model. The proposed reference model makes it possible to define the parameters of a selected mechanism of coordination of actions, and forms a basis for affecting the progression of the process through an analysis of values of identified parameters. The parameterization of elements constitutes the foundation for the monitoring of the process via 1 unambiguous identification of the object of monitoring and 2 analysis of different variants of the progression of the process.

  13. Development of anabolic-androgenic steroids purity certified reference materials for anti-doping.

    Science.gov (United States)

    Quan, Can; Su, Fuhai; Wang, Haifeng; Li, Hongmei

    2011-12-20

    The need for certified reference materials (CRM) of anabolic-androgenic steroids reference materials was emphasized by the Beijing 2008 Olympic game as a tool to improve comparability, ensuring accuracy and traceability of analytical results for competing athletes. The China National Institute of Metrology (NIM) responded to the state request by providing seven anabolic-androgenic steroids (AAS) reference materials for Beijing Olympic anti-doping, GBW (E) 100086-GBW (E) 100092. This work describes the production of the series of AAS CRMs, according to ISO Guides 34 and 35 [1,2], which comprises the material processing, homogeneity and stability assessment, CRMs' characterization including moisture content, trace metal content. The AASs' purity values were assigned with collaborative study involved eight laboratories applying high resolution liquid chromatography-diode array detector (HPLC-DAD). Homogeneity of the AAS CRMs were determined by an in-house validated liquid chromatographic methodology. Potential degradation during storage was also investigated and a shelf-life based on this value was established. The certified values of CRMs were 99.76±0.079%, 99.76±0.25%, 99.63±0.09%, 99.67±0.11%, 98.82±0.56%, 96.30±0.39% and 99.71±0.49% (purity±expanded uncertainty with confidence level of 95%) for methyltestosterone, testosterone propionate, nandrolone, nandrolone 17-propionate, boldenone, trenbolone acetate and testosterone respectively. The certified values for all the studied AAS reference materials are traceable to the international system of units (SI). The CRMs developed were applied by 32 laboratory including sports organizations and analytical laboratories during the 2008 Olympic game for anti-doping control. Copyright © 2011 Elsevier Inc. All rights reserved.

  14. Materials and processing approaches for foundry-compatible transient electronics

    Science.gov (United States)

    Chang, Jan-Kai; Fang, Hui; Bower, Christopher A.; Song, Enming; Yu, Xinge; Rogers, John A.

    2017-07-01

    Foundry-based routes to transient silicon electronic devices have the potential to serve as the manufacturing basis for “green” electronic devices, biodegradable implants, hardware secure data storage systems, and unrecoverable remote devices. This article introduces materials and processing approaches that enable state-of-the-art silicon complementary metal-oxide-semiconductor (CMOS) foundries to be leveraged for high-performance, water-soluble forms of electronics. The key elements are (i) collections of biodegradable electronic materials (e.g., silicon, tungsten, silicon nitride, silicon dioxide) and device architectures that are compatible with manufacturing procedures currently used in the integrated circuit industry, (ii) release schemes and transfer printing methods for integration of multiple ultrathin components formed in this way onto biodegradable polymer substrates, and (iii) planarization and metallization techniques to yield interconnected and fully functional systems. Various CMOS devices and circuit elements created in this fashion and detailed measurements of their electrical characteristics highlight the capabilities. Accelerated dissolution studies in aqueous environments reveal the chemical kinetics associated with the underlying transient behaviors. The results demonstrate the technical feasibility for using foundry-based routes to sophisticated forms of transient electronic devices, with functional capabilities and cost structures that could support diverse applications in the biomedical, military, industrial, and consumer industries.

  15. The Chemical Modeling of Electronic Materials and Interconnections

    Science.gov (United States)

    Kivilahti, J. K.

    2002-12-01

    Thermodynamic and kinetic modeling, together with careful experimental work, is of great help for developing new electronic materials such as lead-free solders, their compatible metallizations and diffusion-barrier layers, as well as joining and bonding processes for advanced electronics manufacturing. When combined, these modeling techniques lead to a rationalization of the trial-and-error methods employed in the electronics industry, limiting experimentation and, thus, reducing significantly time-to-market of new products. This modeling provides useful information on the stabilities of phases (microstructures), driving forces for chemical reactions, and growth rates of reaction products occurring in interconnections or thin-film structures during processing, testing, and in longterm use of electronic devices. This is especially important when manufacturing advanced lead-free electronics where solder joint volumes are decreasing while the number of dissimilar reactive materials is increasing markedly. Therefore, a new concept of local nominal composition was introduced and applied together with the relevant ternary and multicomponent phase diagrams to some solder/conductor systems.

  16. Second-principles method for materials simulations including electron and lattice degrees of freedom

    Science.gov (United States)

    García-Fernández, Pablo; Wojdeł, Jacek C.; Íñiguez, Jorge; Junquera, Javier

    2016-05-01

    We present a first-principles-based (second-principles) scheme that permits large-scale materials simulations including both atomic and electronic degrees of freedom on the same footing. The method is based on a predictive quantum-mechanical theory—e.g., density functional theory—and its accuracy can be systematically improved at a very modest computational cost. Our approach is based on dividing the electron density of the system into a reference part—typically corresponding to the system's neutral, geometry-dependent ground state—and a deformation part—defined as the difference between the actual and reference densities. We then take advantage of the fact that the bulk part of the system's energy depends on the reference density alone; this part can be efficiently and accurately described by a force field, thus avoiding explicit consideration of the electrons. Then, the effects associated to the difference density can be treated perturbatively with good precision by working in a suitably chosen Wannier function basis. Further, the electronic model can be restricted to the bands of interest. All these features combined yield a very flexible and computationally very efficient scheme. Here we present the basic formulation of this approach, as well as a practical strategy to compute model parameters for realistic materials. We illustrate the accuracy and scope of the proposed method with two case studies, namely, the relative stability of various spin arrangements in NiO (featuring complex magnetic interactions in a strongly-correlated oxide) and the formation of a two-dimensional electron gas at the interface between band insulators LaAlO3 and SrTiO3 (featuring subtle electron-lattice couplings and screening effects). We conclude by discussing ways to overcome the limitations of the present approach (most notably, the assumption of a fixed bonding topology), as well as its many envisioned possibilities and future extensions.

  17. Secondary electron interactions in materials with environmental and radiological interest

    International Nuclear Information System (INIS)

    Garcia, G.; Blanco, F.; Pablos, J.L. de; Perez, J.M.; Williart, A.

    2003-01-01

    Important environmental and radiological applications require energy deposition models including the interactions between secondary electrons and the atoms or molecules of the medium. In this work we propose a method to obtain reliable cross-section data to be used in these models by combining total and ionization cross-section measurements with simple calculations of the differential and integral elastic cross-sections. The energy loss spectra obtained in this experiment have been also used to drive stopping power of the considered materials for electrons. Some examples of results for atomic (Xe) and molecular (CF 4 ) targets are presented and discussed in this paper. (author)

  18. The 2016 oxide electronic materials and oxide interfaces roadmap

    DEFF Research Database (Denmark)

    Lorenz, M.; Rao, M. S. Ramachandra; Venkatesan, T.

    2016-01-01

    of these materials to understand the tunability of their properties and the novel properties that evolve due to their nanostructured nature is another facet of the challenge. The research related to the oxide electronic field is at an impressionable stage, and this has motivated us to contribute with a roadmap......, Pentcheva, and Gegenwart. Finally, Miletto Granozio presents the European action ‘towards oxide-based electronics’ which develops an oxide electronics roadmap with emphasis on future nonvolatile memories and the required technologies.In summary, we do hope that this oxide roadmap appears as an interesting...

  19. Spiers memorial lecture. Organic electronics: an organic materials perspective.

    Science.gov (United States)

    Wudl, Fred

    2014-01-01

    This Introductory Lecture is intended to provide a background to Faraday Discussion 174: "Organic Photonics and Electronics" and will consist of a chronological, subjective review of organic electronics. Starting with "ancient history" (1888) and history (1950-present), the article will take us to the present. The principal developments involved the processes of charge carrier generation and charge transport in molecular solids, starting with insulators (photoconductors) and moving to metals, to semiconductors and ending with the most popular semiconductor devices, such as organic light-emitting diodes (OLEDs), organic field effect transistors (OFETs) and organic photovoltaics (OPVs). The presentation will be from an organic chemistry/materials point of view.

  20. NBS SRM 1569 Brewer's Yeast: Is it an adequate standard reference material for testing a chromium determination in biological materials tion in biological materials

    International Nuclear Information System (INIS)

    Goeij, J.J.M. de; Volkers, K.J.; Tjioe, P.S.; Kroon, J.J.

    1978-01-01

    Some analytical experiences with NBS SRM 1569 Brewer's Yeast are presented. Against this background the adequacy of this standard reference material for the determination of chromium in biological materials is discussed. Authors have three main objections. Due to its high content of insoluble chromium-containing particles, SRM 1569 is not typical for biological materials, possibly not even for Brewer's Yeast. The chromium level of SRM 1569 is not typical for the chromium levels normally encountered in pure biological materials. The major fraction (69 +- 3 percent) of the chromium is present in a form which is insoluble under the conditions used in Author's analysis. (T.I.)

  1. Atomic-resolution transmission electron microscopy of electron beam–sensitive crystalline materials

    Science.gov (United States)

    Zhang, Daliang; Zhu, Yihan; Liu, Lingmei; Ying, Xiangrong; Hsiung, Chia-En; Sougrat, Rachid; Li, Kun; Han, Yu

    2018-02-01

    High-resolution imaging of electron beam–sensitive materials is one of the most difficult applications of transmission electron microscopy (TEM). The challenges are manifold, including the acquisition of images with extremely low beam doses, the time-constrained search for crystal zone axes, the precise image alignment, and the accurate determination of the defocus value. We develop a suite of methods to fulfill these requirements and acquire atomic-resolution TEM images of several metal organic frameworks that are generally recognized as highly sensitive to electron beams. The high image resolution allows us to identify individual metal atomic columns, various types of surface termination, and benzene rings in the organic linkers. We also apply our methods to other electron beam–sensitive materials, including the organic-inorganic hybrid perovskite CH3NH3PbBr3.

  2. Atomic-resolution transmission electron microscopy of electron beam–sensitive crystalline materials

    KAUST Repository

    Zhang, Daliang

    2018-01-18

    High-resolution imaging of electron beam-sensitive materials is one of the most difficult applications of transmission electron microscopy (TEM). The challenges are manifold, including the acquisition of images with extremely low beam doses, the time-constrained search for crystal zone axes, the precise image alignment, and the accurate determination of the defocus value. We develop a suite of methods to fulfill these requirements and acquire atomic-resolution TEM images of several metal organic frameworks that are generally recognized as highly sensitive to electron beams. The high image resolution allows us to identify individual metal atomic columns, various types of surface termination, and benzene rings in the organic linkers. We also apply our methods to other electron beam–sensitive materials, including the organic-inorganic hybrid perovskite CH3NH3PbBr3.

  3. Soft Active Materials for Actuation, Sensing, and Electronics

    Science.gov (United States)

    Kramer, Rebecca Krone

    Future generations of robots, electronics, and assistive medical devices will include systems that are soft and elastically deformable, allowing them to adapt their morphology in unstructured environments. This will require soft active materials for actuation, circuitry, and sensing of deformation and contact pressure. The emerging field of soft robotics utilizes these soft active materials to mimic the inherent compliance of natural soft-bodied systems. As the elasticity of robot components increases, the challenges for functionality revert to basic questions of fabrication, materials, and design - whereas such aspects are far more developed for traditional rigid-bodied systems. This thesis will highlight preliminary materials and designs that address the need for soft actuators and sensors, as well as emerging fabrication techniques for manufacturing stretchable circuits and devices based on liquid-embedded elastomers.

  4. Optimization of instrumental neutron activation analysis for the within-bottle homogeneity study of reference materials of marine origin

    International Nuclear Information System (INIS)

    Silva, Daniel Pereira da

    2017-01-01

    The use of reference materials has been increasing in chemical analysis laboratories as its use is important for measurement validation in analytical chemistry. Such materials are generally imported, which require high financial investments in order to acquire them, and therefore it impacts on the difficulty to many national laboratories to use reference materials in their chemical analysis routine. Certification of reference materials is a complex process that assumes that the user is given appropriate assigned values of the properties of interests in the material. In this process, the homogeneity of the material must be checked. In this study, the within-bottle homogeneity study for the elements K, Mg, Mn, Na and V was performed for two reference materials of marine origin: the mussel reference material produced at the Neutron Activation Laboratory (LAN) of IPEN - CNEN/SP and an oyster tissue reference material produced abroad. For this purpose, the elements were determined in subsamples with masses varying between 1 and 250 mg by Instrumental Neutron Activation Analysis (INAA) and minimum sample intakes were estimated, ranging from 0.015 g for Na in the mussel reference material to 0.100 g for V in the two reference materials. (author)

  5. Synthesis Properties and Electron Spin Resonance Properties of Titanic Materials

    International Nuclear Information System (INIS)

    Cho, Jung Min; Lee, Jun; Kim, Tak Hee; Sun, Min Ho; Jang, Young Bae; Cho, Sung June

    2009-01-01

    Titanic materials were synthesized by hydrothermal method of TiO 2 anatase in 10M LiOH, 10M NaOH, and 14M KOH at 130 deg. C for 30 hours. Alkaline media were removed from the synthesized products using 0.1N HCl aqueous solution. The as-prepared samples were characterized by scanning electron microscope, transmission electron microscope, X-ray diffraction, Brunauer-Emmett-Teller isotherm, and electron spin resonance. Different shapes of synthesized products were observed through the typical electron microscope and indicated that the formation of the different morphologies depends on the treatment conditions of highly alkaline media. Many micropores were observed in the cubic or octahedral type of TiO 2 samples through the typical electron microscope and Langmuir adsorption-desorption isotherm of liquid nitrogen at 77 deg. K. Electron spin resonance studies have also been carried out to verify the existence of paramagnetic sites such as oxygen vacancies on the titania samples. The effect of alkali metal ions on the morphologies and physicochemical properties of nanoscale titania are discussed.

  6. High-resolution electron microscopy of advanced materials

    Energy Technology Data Exchange (ETDEWEB)

    Mitchell, T.E.; Kung, H.H.; Sickafus, K.E.; Gray, G.T. III; Field, R.D.; Smith, J.F. [Los Alamos National Lab., NM (United States). Materials Science and Technology Div.

    1997-11-01

    This final report chronicles a three-year, Laboratory Directed Research and Development (LDRD) project at Los Alamos National Laboratory (LANL). The High-Resolution Electron Microscopy Facility has doubled in size and tripled in quality since the beginning of the three-year period. The facility now includes a field-emission scanning electron microscope, a 100 kV field-emission scanning transmission electron microscope (FE-STEM), a 300 kV field-emission high-resolution transmission electron microscope (FE-HRTEM), and a 300 kV analytical transmission electron microscope. A new orientation imaging microscope is being installed. X-ray energy dispersive spectrometers for chemical analysis are available on all four microscopes; parallel electron energy loss spectrometers are operational on the FE-STEM and FE-HRTEM. These systems enable evaluation of local atomic bonding, as well as chemical composition in nanometer-scale regions. The FE-HRTEM has a point-to-point resolution of 1.6 {angstrom}, but the resolution can be pushed to its information limit of 1 {angstrom} by computer reconstruction of a focal series of images. HRTEM has been used to image the atomic structure of defects such as dislocations, grain boundaries, and interfaces in a variety of materials from superconductors and ferroelectrics to structural ceramics and intermetallics.

  7. The production and certification of a plutonium equal-atom reference material: NBL CRM 128

    International Nuclear Information System (INIS)

    Crawford, D.W.

    1990-07-01

    This report describes the design, production, and certification of the New Brunswick Laboratory plutonium equal-atom certified reference material (CRM), NBL CRM 128. The primary use of this CRM is for the determination of bias corrections encountered in the operation of a mass spectrometer. This reference material is available to the US Department of Energy contractor-operated and government-operated laboratories, as well as to the international nuclear safeguards community. The absolute, or unbiased, certified value for the CRM's Pu-242/Pu-239 ratio is 1.00063 ± 0.00026 (95% confidence interval) as of October 1, 1984. This value was obtained through the quantitative blending of high-purity, chemically and isotopically characterized separated isotopes, as well as through intercomparisons of CRM samples with calibration mixtures using thermal ionization mass spectrometry. 32 tabs

  8. Certified reference materials for analytical quality control in neutron activation analysis

    International Nuclear Information System (INIS)

    Wee Boon Siong; Abdul Khalik Wood; Mohd Suhaimi Hamzah; Shamsiah Abdul Rahman; Mohd Suhaimi Elias; Nazaratul Ashifa Abdul Salim

    2007-01-01

    Analytical quality control in neutron activation analysis (NAA) requires the use of certified reference materials (CRM) in order to produce reliable analytical results. It is essential to evaluate the performance of NAA method when analyzing various sample matrices. Therefore, the CRM selected for an analysis should be suitable for the type of samples. There are many aspects such as concentration range, matrix match, sample size and uncertainty, which need to be considered when selecting a suitable CRM. Eventually, results of analysis of CRM were plotted into control charts in order to evaluate the qualify of the data. This is to ensure that the results are within the 95 % confidence interval as stipulated in the certificate of CRM. Thus, this article aims to discuss the uses of certified reference materials for quality control purposes in NAA involving various sample matrices. (author)

  9. Comparison of relative INAA and k0-INAA using soil and sediment reference materials

    International Nuclear Information System (INIS)

    Jacimovic, R.

    2014-01-01

    The objective of this work was to compare the results obtained by the relative INAA and k 0 -INAA methods for the same input parameters (sample mass, nuclear data, net peak area for the same gamma line and the same measurement and same cooling and measurement times). In total eight environmental soil and sediment reference materials (RM) or certified reference materials (CRM) from different producers were analysed. In this work only the recommended or certified values were considered, allowing comparison of the two methods for 30 elements. The results point out that k 0 -INAA possesses superior qualities compared to relative INAA, being insensitive to flux gradients, and independent of recommended/certified values in RMs/CRMs, often used as standards in relative INAA. (author)

  10. The preparation and analysis of minerals for use as reference material

    International Nuclear Information System (INIS)

    Stoch, H.

    1976-01-01

    This report covers the progress made in the collection of the material for reference samples, and the five interlaboratory analytical programmes (ferrochromium slags, fluorspar, 'mixed' NIMROC samples, rare earths, and ferromanganese slags). The description of the internal analytical programme has been subdivided into eight main categories, and a comprehensive list of evaluated results covering a wide range of materials is included. Additional results for thorium, rare earths, tin, tantalum, and niobium for the appropriate reference samples are included in updated tables. The main purpose in the preparation of these samples is to provide control samples for analytical work at the National Institute for Metallurgy. Where there is a special need, limited quantities of the samples can be made available to other laboratories

  11. Instrumental neutron activation analysis of proposed marine sediment reference material (IAEA-158)

    International Nuclear Information System (INIS)

    Siddique, N.; Waheed, S.

    2009-01-01

    IAEA-158, sediment prepared by the International Atomic Energy Agency -Marine Environmental Laboratory (IAEA-MEL), Monaco was received under the IAEA Analytical Quality Control Services (AQCS) Intercomparison Programme. Instrumental Neutron Activation Analysis (INAA) was used to determine AI, As, Br, Ce, Co, Cr, Cs, Eu, Fe, Hf, K, La, Lu, Mn, Na, Nd, Rb, Sb, Sc, Se, Sm, Ta, Tb, Th, V, Vb and Zn in this proposed reference material (RM). Four different irradiation protocols were adopted using a miniature neutron source reactor (MNSR) by varying the irradiation, cooling and counting times. IAEA-405 (Estuarine Sediment) and IAEA-SLI (Lake Sediment) were used as compatible matrix reference materials for quality assurance (QA) purposes. Good agreement between our data and lAEA certified values was obtained providing confidence in the reported data. (author)

  12. Reference Materials for Calibration of Analytical Biases in Quantification of DNA Methylation.

    Science.gov (United States)

    Yu, Hannah; Hahn, Yoonsoo; Yang, Inchul

    2015-01-01

    Most contemporary methods for the quantification of DNA methylation employ bisulfite conversion and PCR amplification. However, many reports have indicated that bisulfite-mediated PCR methodologies can result in inaccurate measurements of DNA methylation owing to amplification biases. To calibrate analytical biases in quantification of gene methylation, especially those that arise during PCR, we utilized reference materials that represent exact bisulfite-converted sequences with 0% and 100% methylation status of specific genes. After determining relative quantities using qPCR, pairs of plasmids were gravimetrically mixed to generate working standards with predefined DNA methylation levels at 10% intervals in terms of mole fractions. The working standards were used as controls to optimize the experimental conditions and also as calibration standards in melting-based and sequencing-based analyses of DNA methylation. Use of the reference materials enabled precise characterization and proper calibration of various biases during PCR and subsequent methylation measurement processes, resulting in accurate measurements.

  13. Analysis of soil reference materials for vanadium(+5) species by electrothermal atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Mandiwana, Khakhathi L.; Panichev, Nikolay

    2010-01-01

    Solid Certified Reference Materials (CRMs) with known vanadium(+5) content are currently not commercially available. Because of this, vanadium species have been determined in solid CRMs of soil, viz. CRM023-50, CRM024-50, CRM049-50, SQC001 and SQC0012. These CRMs are certified with only total vanadium content. Vanadium(+5) was extracted from soil reference materials with 0.1 M Na 2 CO 3 . The quantification of V(+5) was carried out by electrothermal atomic absorption spectrometry (ET-AAS). The concentration of V(+5) in the analyzed CRMs was found to be ranging between 3.60 and 86.0 μg g -1 . It was also found that SQC001 contains approximately 88% of vanadium as V(+5) species. Statistical evaluation of the results of the two methods by paired t-test was in good agreement at 95% level of confidence.

  14. Homogeneity study on biological candidate reference materials: the role of neutron activation analysis

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Daniel P.; Moreira, Edson G., E-mail: dsilva.pereira@usp.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2015-07-01

    Instrumental Neutron activation Analysis (INAA) is a mature nuclear analytical technique able to accurately determine chemical elements without the need of sample digestion and, hence, without the associated problems of analyte loss or contamination. This feature, along with its potentiality use as a primary method of analysis, makes it an important tool for the characterization of new references materials and in the assessment of their homogeneity status. In this study, the ability of the comparative method of INAA for the within-bottle homogeneity of K, Mg, Mn and V in a mussel reference material was investigated. Method parameters, such as irradiation time, sample decay time and distance from sample to the detector were varied in order to allow element determination in subsamples of different sample masses in duplicate. Sample masses were in the range of 1 to 250 mg and the limitations of the detection limit for small sample masses and dead time distortions for large sample masses were investigated. (author)

  15. Certification of a niobium metal reference material for neutron dosimetry (EC-NRM 525)

    International Nuclear Information System (INIS)

    Lievens, F.; Ingelbrecht, C.; Pauwels, J.

    1990-01-01

    Niobium metal, of 99.98% nominal purity, in the form of 0.02 and 0.1 mm thick foils and of 0.5 mm diameter wire, has been certified for its tantalum mass fraction. The certified value of the tantalum mass fraction is 19.6 ± 1.8 mg.kg -1 and is based on 71 results obtained by six laboratories by neutron activation analysis or inductively coupled plasma source mass spectrometry. The material is intended to be used as a reference material in neutron metrology

  16. Certified Reference Material IAEA-446 for radionuclides in Baltic Sea seaweed

    DEFF Research Database (Denmark)

    Pham, M.K.; Benmansour, M.; Carvalho, F.P.

    2014-01-01

    A Certified Reference Material (CRM) for radionuclides in seaweed (Fucus vesiculosus) from the Baltic Sea (IAEA-446) is described and the results of the certification process are presented. The 40K, 137Cs, 234U and 239þ240Pu radionuclides were certified for this material, and information values...... for 12 other radionuclides (90Sr, 99Tc, 210Pb (210Po), 226Ra, 228Ra, 228Th, 230Th, 232Th, 235U, 238U, 239Pu and 240Pu) are presented. The CRM can be used for Quality Assurance/Quality Control of analysis of radionuclides in seaweed and other biota samples, as well as for development and validation...

  17. Candidate coffee reference material for element content: production and certification schemes adopted at CENA/USP

    Energy Technology Data Exchange (ETDEWEB)

    Tagliaferro, Fabio Sileno; Fernandes, Elisabete A. de Nadai; Bacchi, Marcio Arruda; Franca, Elvis Joacir de [Centro de Energia Nuclear na Agricultura (CENA/USP), Piracicaba, SP (Brazil). Lab. de Radioisotopos], e-mail: fabiotag@cena.usp.br, e-mail: lis@cena.usp.br, e-mail: mabacchi@cena.usp.br, e-mail: ejfranca@cena.usp.br; Bode, Peter; Bacchi, Marcio Arruda; Franca, Elvis Joacir de [Delft University of Technology, Delft (Netherlands). Interfaculty Reactor Inst.], e-mail: P.Bode@iri.tudelft.nl

    2003-07-01

    Certified reference materials (CRMs) play a fundamental role in analytical chemistry establishing the traceability of measurement results and assuring accuracy and reliability. In spite of the huge importance of measurements in the food sector, Brazil does not produce CRMs to supply the demand. Consequently the acquisition of CRMs depends on imports at high costs. The coffee sector needs CRMs, however there is no material that represents the coffee composition. Since 1998, the Laboratorio de Radioisotopos (LRi) of CENA/USP has been involved in analysis of coffee. During this period, knowledge has been accumulated about several aspects of coffee, such as system of cultivation, elemental composition, homogeneity of the material, possible contaminants and physical properties of beans. Concomitantly, LRi has concentrated efforts in the field of metrology in chemistry, and now all this expertise is being used as the basis for the production of a coffee certified reference material (CRM) for inorganic element content. The scheme developed for the preparation and certification of coffee RM relies on the ISO Guides 34 and 35. The approaches for selection, collection and preparation of the material, moisture determination method, homogeneity testing, certification and long-term stability testing are discussed and a time frame for the expected accomplishments is provided. (author)

  18. Candidate coffee reference material for element content: production and certification schemes adopted at CENA/USP

    International Nuclear Information System (INIS)

    Tagliaferro, Fabio Sileno; Fernandes, Elisabete A. de Nadai; Bacchi, Marcio Arruda; Franca, Elvis Joacir de; Bode, Peter; Bacchi, Marcio Arruda; Franca, Elvis Joacir de

    2003-01-01

    Certified reference materials (CRMs) play a fundamental role in analytical chemistry establishing the traceability of measurement results and assuring accuracy and reliability. In spite of the huge importance of measurements in the food sector, Brazil does not produce CRMs to supply the demand. Consequently the acquisition of CRMs depends on imports at high costs. The coffee sector needs CRMs, however there is no material that represents the coffee composition. Since 1998, the Laboratorio de Radioisotopos (LRi) of CENA/USP has been involved in analysis of coffee. During this period, knowledge has been accumulated about several aspects of coffee, such as system of cultivation, elemental composition, homogeneity of the material, possible contaminants and physical properties of beans. Concomitantly, LRi has concentrated efforts in the field of metrology in chemistry, and now all this expertise is being used as the basis for the production of a coffee certified reference material (CRM) for inorganic element content. The scheme developed for the preparation and certification of coffee RM relies on the ISO Guides 34 and 35. The approaches for selection, collection and preparation of the material, moisture determination method, homogeneity testing, certification and long-term stability testing are discussed and a time frame for the expected accomplishments is provided. (author)

  19. An EPMA study on KNbO3 and NaNbO3 single crystals - potential reference materials for quantitative microanalysis

    International Nuclear Information System (INIS)

    Samardzzija, Z.; Bernik, S.; Malic, B.; Ceh, M.; Marinenko, R.B.

    2004-01-01

    Single crystals of KNbO 3 and NaNbO 3 were selected from the limited number of suitable alkali compounds that are available and evaluated as possible reference materials for the electron-probe microanalysis (EPMA) of alkaline niobates with a composition described by the general formula K 1-x Na x NbO 3 . The EPMA study verified that KNbO 3 and NaNbO 3 single crystals are stable under the electron beam and compositionally homogeneous. A quantitative microanalysis confirmed the composition of pure KNbO 3 , while the NaNbO 3 crystal contained 0.3 mass fraction % of Ca. A significant improvement in the accuracy of the quantitative EPMA of polycrystalline potassium-sodium niobates was achieved using these single crystals as standards. The crystals can also be useful as reference materials for the analysis of sodium and potassium in other materials. (author)

  20. Measurement of polybrominated diphenyl ethers in environmental matrix standard reference materials

    Energy Technology Data Exchange (ETDEWEB)

    Stapleton, H.; Schantz, M.; Wise, S. (National Institute of Standards and Technology)

    2004-09-15

    Polybrominated diphenyl ethers (PBDEs) are a class of emerging contaminants of concern as many studies have now demonstrated that these compounds are bioaccumulative, persistent and increasing in concentration in the environment. PBDEs are being detected in almost every environmental sample examined, and they have even been measured in samples collected in the Arctic, further demonstrating their persistence and potential for long range transport. More and more studies are continuing to examine the fate and transport of these flame retardant compounds in environmental samples and as such, reference materials are needed to provide quality control on these measurements. The National Institute of Standards and Technology (NIST) supports a national Standard Reference Material (SRM) program for measurement of organic contaminants such as PCBs, PAHs and chlorinated pesticides in environmental matrices. This current study was undertaken to provide reference measurements for PBDEs in selected SRMs that are currently used by various laboratories throughout the United States. These SRMs include matrices such as marine mammal blubber, lake trout tissue, mussel tissue, sediment, house dust and human serum. We report here reference values for 22 PBDE congeners that have been quantified in these seven types of SRMs.

  1. Austenitic chromium nickel steel as standard reference material in measurement of thermal and temperature conductivity

    International Nuclear Information System (INIS)

    Binkele, L.

    1990-01-01

    A niobium-stabilized CrNi steel with the NBS designation SRM 735 is introduced as WLF standard reference material in a report by Hust and Giarratano, for the temperature range 300-1200 K and for thermal conductivities around 20 W/mk. However, its specification does not show it to be a direct member of the DIN family of CrNi steels. This report should be regarded as a continuation and supplement to the above-mentioned efforts in America. On the one hand, a solution of a possibly too-narrow specification is aimed at for the reference material, where it is important how sensitive the thermal conductivity is to changes in the chemical composition and changes of the manufacturing parameters and what accuracy can be reached for the reference values with the best measurement techniques. On the other hand, the data base should be expanded and the accuracy of the reference curve should be improved if possible. (orig./MM) [de

  2. Introducing LIR (Lithotheque Ireland, a reference collection of flaked stone tool raw materials from Ireland

    Directory of Open Access Journals (Sweden)

    Killian Driscoll

    2016-09-01

    Full Text Available The LIR (Lithotheque Ireland reference collection of flaked stone tool raw materials from Ireland began in 2013, and is based on the geological prospection from two projects. The first (2013-2015 focused attention primarily on Carboniferous cherts from the northwest of Ireland, collecting 405 samples. The second (2015-2017 is currently collecting samples of the Cretaceous flint primarily from in situ contexts in the northeast of Ireland, but also includes beach surveys of Cretaceous flint from around the island; the first phase of geological prospection in Autumn 2015 collected 239 samples, with the geological prospection continuing in 2016. Therefore, to date the collection contains over 600 hand samples of chert and flint, along with a small number of other materials (siliceous limestone, tuff, mudstone. The physical reference collection is housed at the UCD School of Archaeology, University College Dublin and contains the geological hand samples along with the various thin sections of the samples that are used for petrographic analysis. The physical collection is complemented by an online database that is to be used alongside the physical collection, or can be used as a stand-alone resource. This paper provides an overview of the database’s metadata and the processes of data entry and editing, to serve as a reference point for the database and the fieldwork undertaken to date, and to serve as a template for other researchers undertaking similar work on lithic reference collections.

  3. Use of analytical electron microscopy and auger electron spectroscopy for evaluating materials

    International Nuclear Information System (INIS)

    Jones, R.H.; Bruemmer, S.M.; Thomas, M.T.; Baer, D.R.

    1982-11-01

    Analytical electron microscopy (AEM) can be used to characterize the microstructure and microchemistry of materials over dimensions less than 10 nm while Auger electron spectroscopy (AES) can be used to characterize the chemical composition of surfaces and interfaces to a depth of less than 1 nm. Frequently, the information gained from both instruments can be coupled to give new insight into the behavior of materials. Examples of the use of AEM and AES to characterize segregation, sensitization and radiation damage are presented. A short description of the AEM and AES techniques are given

  4. Initial testing of a neutron activation analysis system by analysing standard reference materials

    International Nuclear Information System (INIS)

    Suhaimi Hamzah; Roslan Idris; Abdul Khalik Haji Wood; Che Seman Mahmood; Abdul Rahim Mohamad Noor.

    1983-01-01

    This paper describes the data acquisition and processing system in our laboratories (ND6600), the methods of activation analysis and the results obtained from our analysis of IAEA standard reference material (SL-l lake sediments and NBS coal ash 1632a). These standards were analysed in order to check the capability of the system, which was designed in such a way as to enable the user to independently collect and process data from multiple radiation detectors. (author)

  5. Stability of aflatoxin B1 in animal feed candidate reference materials

    NARCIS (Netherlands)

    Roos, A.H.; Mazijk, van R.J.; Tuinstra, L.G.M.T.; Huf, F.A.

    1991-01-01

    Two candidate reference materials animal feed were stored at a temperature of -18°C, 4 C, 20°C and 37°C. The stability of aflatoxin B1 was studied duringa period of two years. A significant decrease in the aflatoxin B1 content was measured in the samples stared at 20°C and 37°C. In the samples

  6. The role of adequate reference materials in density measurements in hemodialysis

    Science.gov (United States)

    Furtado, A.; Moutinho, J.; Moura, S.; Oliveira, F.; Filipe, E.

    2015-02-01

    In hemodialysis, oscillation-type density meters are used to measure the density of the acid component of the dialysate solutions used in the treatment of kidney patients. An incorrect density determination of this solution used in hemodialysis treatments can cause several and adverse events to patients. Therefore, despite the Fresenius Medical Care (FME) tight control of the density meters calibration results, this study shows the benefits of mimic the matrix usually measured to produce suitable reference materials for the density meter calibrations.

  7. The role of adequate reference materials in density measurements in hemodialysis

    International Nuclear Information System (INIS)

    Furtado, A; Moura, S; Filipe, E; Moutinho, J; Oliveira, F

    2015-01-01

    In hemodialysis, oscillation-type density meters are used to measure the density of the acid component of the dialysate solutions used in the treatment of kidney patients. An incorrect density determination of this solution used in hemodialysis treatments can cause several and adverse events to patients. Therefore, despite the Fresenius Medical Care (FME) tight control of the density meters calibration results, this study shows the benefits of mimic the matrix usually measured to produce suitable reference materials for the density meter calibrations

  8. Determination of element concentrations in biological reference materials by solid sampling and other analytical methods

    International Nuclear Information System (INIS)

    Schauenburg, H.; Weigert, P.

    1992-01-01

    Using solid sampling with graphite furnace atomic absorption spectrometry (GFAAS), values for cadmium, copper, lead and zinc in six biological reference materials were obtained from up to four laboratories participating in three collaborative studies. These results are compared with those obtained with other methods used in routine analysis from laboratories of official food control. Under certain conditions solid sampling with GFAAS seems to be suitable for routine analysis as well as conventional methods. (orig.)

  9. Neutron activation analysis of reference materials by the k sub 0 standardization and relative methods

    Energy Technology Data Exchange (ETDEWEB)

    Freitas, M C; Martinho, E [LNETI/ICEN, Sacavem (Portugal)

    1989-04-15

    Instrumental neutron activation analysis with the k{sub o}-standardization method was applied to eight geological, environmental and biological reference materials, including leaves, blood, fish, sediments, soils and limestone. To a first approximation, the results were normally distributed around the certified values with a standard deviation of 10%. Results obtained by using the relative method based on well characterized multi-element standards for IAEA CRM Soil-7 are reported.

  10. Production and certification of reference materials; Producao e certificacao de materiais de referencia

    Energy Technology Data Exchange (ETDEWEB)

    Sarkis, Jorge Eduardo de S.; Kakazu, Mauricio H; Hespanhol, Emilio Carlos B; Martins, Elaine Arantes J [Instituto de Pesquisas Energeticas e Nucleares (IPEN), Sao Paulo, SP (Brazil)

    1996-07-01

    The reference materials used in analytical chemistry permit us to evaluate correctly the analytical producers as well as experimental set up. U{sub 3} O{sub 8} was produced at IPEN to be used as a secondary standard. We present the first results on U{sub 3} O{sub 8} and discuss the method, preparation, and characterization of that oxide. (author)

  11. Development of benzene, toluene, ethylbenzene and xylenes certified gaseous reference materials

    Science.gov (United States)

    Brum, M. C.; Sobrinho, D. C. G.; Fagundes, F. A.; Oudwater, R. J.; Augusto, C. R.

    2016-07-01

    The work describes the production of certified gaseous reference materials of benzene, toluene, ethylbenzene and xylenes (BTEX) in nitrogen from the gravimetric production up to the long term stability tests followed by the certifying step. The uncertainty in the amount fractions of the compounds in these mixtures was approximately 4% (relative) for the range studied from 2 to 16 µmol/mol. Also the adsorption of the BTEX on the cylinder surface and the tubing were investigated as potential uncertainty source.

  12. Evaluation of the effect of tooth and dental restoration material on electron dose distribution and production of photon contamination in electron beam radiotherapy.

    Science.gov (United States)

    Bahreyni Toossi, Mohammad Taghi; Ghorbani, Mahdi; Akbari, Fatemeh; Mehrpouyan, Mohammad; Sobhkhiz Sabet, Leila

    2016-03-01

    The aim of this study is to evaluate the effect of tooth and dental restoration materials on electron dose distribution and photon contamination production in electron beams of a medical linac. This evaluation was performed on 8, 12 and 14 MeV electron beams of a Siemens Primus linac. MCNPX Monte Carlo code was utilized and a 10 × 10 cm(2) applicator was simulated in the cases of tooth and combinations of tooth and Ceramco C3 ceramic veneer, tooth and Eclipse alloy and tooth and amalgam restoration materials in a soft tissue phantom. The relative electron and photon contamination doses were calculated for these materials. The presence of tooth and dental restoration material changed the electron dose distribution and photon contamination in phantom, depending on the type of the restoration material and electron beam's energy. The maximum relative electron dose was 1.07 in the presence of tooth including amalgam for 14 MeV electron beam. When 100.00 cGy was prescribed for the reference point, the maximum absolute electron dose was 105.10 cGy in the presence of amalgam for 12 MeV electron beam and the maximum absolute photon contamination dose was 376.67 μGy for tooth in 14 MeV electron beam. The change in electron dose distribution should be considered in treatment planning, when teeth are irradiated in electron beam radiotherapy. If treatment planning can be performed in such a way that the teeth are excluded from primary irradiation, the potential errors in dose delivery to the tumour and normal tissues can be avoided.

  13. Evaluation of the effect of tooth and dental restoration material on electron dose distribution and production of photon contamination in electron beam radiotherapy

    International Nuclear Information System (INIS)

    Bahreyni Toossi, M.T.; Ghorbani, Mahdi; Akbari, Fatemah; Sabet, Leila S.; Mehrpouyan, Mohammad

    2016-01-01

    The aim of this study is to evaluate the effect of tooth and dental restoration materials on electron dose distribution and photon contamination production in electron beams of a medical linac. This evaluation was performed on 8, 12 and 14 MeV electron beams of a Siemens Primus linac. MCNPX Monte Carlo code was utilized and a 10 × 10 cm 2 applicator was simulated in the cases of tooth and combinations of tooth and Ceramco C3 ceramic veneer, tooth and Eclipse alloy and tooth and amalgam restoration materials in a soft tissue phantom. The relative electron and photon contamination doses were calculated for these materials. The presence of tooth and dental restoration material changed the electron dose distribution and photon contamination in phantom, depending on the type of the restoration material and electron beam’s energy. The maximum relative electron dose was 1.07 in the presence of tooth including amalgam for 14 MeV electron beam. When 100.00 cGy was prescribed for the reference point, the maximum absolute electron dose was 105.10 cGy in the presence of amalgam for 12 MeV electron beam and the maximum absolute photon contamination dose was 376.67 μGy for tooth in 14 MeV electron beam. The change in electron dose distribution should be considered in treatment planning, when teeth are irradiated in electron beam radiotherapy. If treatment planning can be performed in such a way that the teeth are excluded from primary irradiation, the potential errors in dose delivery to the tumour and normal tissues can be avoided.

  14. Certified reference material IAEA-418: I-129 in Mediterranean sea water

    International Nuclear Information System (INIS)

    2009-01-01

    Our society is attaching increasing importance to the study and assessment of the state and health of the environment. Organizations involved in such activities rely on the quality of the information provided and, ultimately, on the precision and accuracy of the data on which the information is based. Many laboratories are involved in the production of environmental data in many cases leading to wider assessments. These laboratories may develop and validate new analytical methods, study the environmental impact of human activities, provide services to other organizations, etc. In particular, laboratories are providing data on levels of radioactivity in a variety of marine matrixes such as water, suspended matter, sediments and biota. Because of the need to base scientific conclusions on valid and internationally comparable data, the need to provide policy makers with correct information and the need for society to be informed of the state of the environment, it is indispensable to ensure the quality of the data produced by each laboratory. Principles of good laboratory practice require both internal and external procedures to verify the quality of the data produced. Internal quality is verified in a number of ways such as the use of laboratory information systems, keeping full records of equipment performance and standardization of analytical procedures. External quality can also be ascertained in a number of ways, notably accreditation by an external body under a defined quality scheme but also, amongst others, the use of internationally accepted calibration standards that are traceable to the SI international system of units, the participation in interlaboratory comparisons or the regular use of reference materials to test laboratory performance. The Radiometrics Laboratory of the IAEA Marine Environment Laboratories has been providing quality products for the last 40 years which include the organization of interlaboratory comparisons, proficiency tests

  15. Multielement comparison of instrumental neutron activation analysis techniques using reference materials

    International Nuclear Information System (INIS)

    Ratner, R.T.; Vernetson, W.G.

    1995-01-01

    Several instrumental neutron activation analysis techniques (parametric, comparative, and k o -standardization) are evaluated using three reference materials. Each technique is applied to National Institute of Standards and Technology standard reference materials, SRM 1577a (Bovine Liver) and SRM 2704 (Buffalo River Sediment), and the United States Geological Survey standard BHVO-1 (Hawaiian Basalt Rock). Identical (but not optimum) irradiation, decay, and counting schemes are employed with each technique to provide a basis for comparison and to determine sensitivities in a routine irradiation scheme. Fifty-one elements are used in this comparison; however, several elements are not detected in the reference materials due to rigid analytical conditions (e.g. insufficient length of irradiation or activity for radioisotope of interest decaying below the lower limit of detection before counting interval). Most elements are normally distributed around certified or consensus values with a standard deviation of 10%. For some elements, discrepancies are observed and discussed. The accuracy, precision, and sensitivity of each technique are discussed by comparing the analytical results to consensus values for the Hawaiian Basalt Rock to demonstrate the diversity of multielement applications. (author) 4 refs.; 2 tabs

  16. Attosecond Electron Processes in Materials: Excitons, Plasmons, and Charge Dynamics

    Science.gov (United States)

    2015-05-19

    focused using a f=1.5 m lens into a 250 micron hollow core fiber (HCF) filled with neon gas at atmospheric pressure to stretch the pulse spectrum from... insulator to metal transition. Introduction: The goal of this work was to understand the generation, transport, and manipulation of electronic charge...chemically sensitive probe pulse utilizing specific core level transitions in atoms that are part of a material under study. The measurements follow

  17. Nanocellulose as Material Building Block for Energy and Flexible Electronics

    Science.gov (United States)

    Hu, Liangbing

    2014-03-01

    In this talk, I will discuss the fabrications, properties and device applications of functional nanostructured paper based on nanocellulose. Nanostructures with tunable optical, electrical, ionic and mechanical properties will be discussed. Lab-scale demonstration devices, including low-cost Na-ion batteries, microbial fuel cells, solar cells, transparent transistors, actuators and touch screens will be briefly mentioned. These studies show that nanocellulose is a promising green material for electronics and energy devices.

  18. Electron Acceptor Materials Engineering in Colloidal Quantum Dot Solar Cells

    KAUST Repository

    Liu, Huan

    2011-07-15

    Lead sulfide colloidal quantum dot (CQD) solar cells with a solar power conversion efficiency of 5.6% are reported. The result is achieved through careful optimization of the titanium dioxide electrode that serves as the electron acceptor. Metal-ion-doped sol-gel-derived titanium dioxide electrodes produce a tunable-bandedge, well-passivated materials platform for CQD solar cell optimization. © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  19. A study on homogeneity of the IAEA candidate reference materials for microanalysis and analytical support in the certification of these materials

    International Nuclear Information System (INIS)

    Dybczynski, R.; Danko, B.; Polkowska-Motrenko, H.

    2002-01-01

    In this paper a study on homogeneity of new IAEA candidate reference materials: IAEA 338 Lichen and IAEA 413 Algae in small (ca.10 mg) samples as well as some data contributing to certification of these materials are presented. (author)

  20. The urgent requirement for new radioanalytical certified reference materials for nuclear safeguards, forensics, and consequence management

    International Nuclear Information System (INIS)

    Inn, K.G.W.; Martin Johnson, Jr.C.; Warren Oldham; Lav Tandon; Simon Jerome; Thomas Schaaff; Robert Jones; Daniel Mackney; Pam MacKill; Brett Palmer

    2013-01-01

    A multi-agency workshop was held from 25 to 27 August 2009, at the National Institute of Standards and Technology (NIST), to identify and prioritize the development of radioanalytical Certified Reference Materials (CRMs, generally provided by National Metrology Institutes; Standard Reference Materials, a CRM issued by NIST) for field and laboratory nuclear measurement methods to be used to assess the consequences of a domestic or international nuclear event. Without these CRMs, policy makers concerned with detecting proliferation and trafficking of nuclear materials, attribution and retribution following a nuclear event, and public health consequences of a nuclear event would have difficulty making decisions based on analytical data that would stand up to scientific, public, and judicial scrutiny. The workshop concentrated on three areas: post-incident Improvised Nuclear Device (IND) nuclear forensics, safeguard materials characterization, and consequence management for an IND or a Radiological Dispersion Device detonation scenario. The workshop identified specific CRM requirements to fulfill the needs for these three measurement communities. Of highest priority are: (1) isotope dilution mass spectrometry standards, specifically 233 U, 236 gNp, 244 Pu, and 243 Am, used for quantitative analysis of the respective elements that are in critically short supply and in urgent need of replenishment and certification; (2) CRMs that are urgently needed for post-detonation debris analysis of actinides and fission fragments, and (3) CRMs used for destructive and nondestructive analyses for safeguards measurements, and radioisotopes of interest in environmental matrices. (author)

  1. 230Th-234U Model-Ages of Some Uranium Standard Reference Materials

    International Nuclear Information System (INIS)

    Williams, R.W.; Gaffney, A.M.; Kristo, M.J.; Hutcheon, I.D.

    2009-01-01

    The 'age' of a sample of uranium is an important aspect of a nuclear forensic investigation and of the attribution of the material to its source. To the extent that the sample obeys the standard rules of radiochronometry, then the production ages of even very recent material can be determined using the 230 Th- 234 U chronometer. These standard rules may be summarized as (a) the daughter/parent ratio at time=zero must be known, and (b) there has been no daughter/parent fractionation since production. For most samples of uranium, the 'ages' determined using this chronometer are semantically 'model-ages' because (a) some assumption of the initial 230 Th content in the sample is required and (b) closed-system behavior is assumed. The uranium standard reference materials originally prepared and distributed by the former US National Bureau of Standards and now distributed by New Brunswick Laboratory as certified reference materials (NBS SRM = NBL CRM) are good candidates for samples where both rules are met. The U isotopic standards have known purification and production dates, and closed-system behavior in the solid form (U 3 O 8 ) may be assumed with confidence. We present here 230 Th- 234 U model-ages for several of these standards, determined by isotope dilution mass spectrometry using a multicollector ICP-MS, and compare these ages with their known production history

  2. The NISTmAb Reference Material 8671 lifecycle management and quality plan.

    Science.gov (United States)

    Schiel, John E; Turner, Abigail

    2018-03-01

    Comprehensive analysis of monoclonal antibody therapeutics involves an ever expanding cadre of technologies. Lifecycle-appropriate application of current and emerging techniques requires rigorous testing followed by discussion between industry and regulators in a pre-competitive space, an effort that may be facilitated by a widely available test metric. Biopharmaceutical quality materials, however, are often difficult to access and/or are protected by intellectual property rights. The NISTmAb, humanized IgG1κ Reference Material 8671 (RM 8671), has been established with the intent of filling that void. The NISTmAb embodies the quality and characteristics of a typical biopharmaceutical product, is widely available to the biopharmaceutical community, and is an open innovation tool for development and dissemination of results. The NISTmAb lifecyle management plan described herein provides a hierarchical strategy for maintenance of quality over time through rigorous method qualification detailed in additional submissions in the current publication series. The NISTmAb RM 8671 is a representative monoclonal antibody material and provides a means to continually evaluate current best practices, promote innovative approaches, and inform regulatory paradigms as technology advances. Graphical abstract The NISTmAb Reference Material (RM) 8671 is intended to be an industry standard monoclonal antibody for pre-competitive harmonization of best practices and designing next generation characterization technologies for identity, quality, and stability testing.

  3. The use of reference materials in the elemental analysis of biological samples

    International Nuclear Information System (INIS)

    Bowen, H.J.M.

    1975-01-01

    Reference materials (RMs) are useful to compare the accuracy and precision of laboratories and techniques. The desirable properties of biological reference materials are listed, and the problems of production, homogenization and storage described. At present there are only 10 biological RMs available compared with 213 geological and 520 metallurgical RMs. There is a need for more biological RMs including special materials for microprobe analysis and for in vivo activation analysis. A study of 650 mean values for elements in RM Kale, analysed by many laboratories, leads to the following conclusions. 61% of the values lie within +-10% of the best mean, and 80% lie within +-20% of the best mean. Atomic absorption spectrometry gives results that are 5-30% high for seven elements, while intrumental neutron activation analysis gives low and imprecise results for K. Other techniques with poor interlaboratory precision include neutron activation for Mg, polarography for Zn and arc-spectrometry for many elements. More than half the values for elements in Kale were obtained by neutron activation, confirming the importance of this technique and the need for RMs. As a rough estimate, 6 x 10 9 elemental analyses of biological materials are carried out each year, mostly by medical, agricultural and food scientists. It seems likely that a substantial percentage of these are inaccurate, a situation that might be improved by quality control using standard RMs. (author)

  4. 230Th-234U Model-Ages of Some Uranium Standard Reference Materials

    Energy Technology Data Exchange (ETDEWEB)

    Williams, R W; Gaffney, A M; Kristo, M J; Hutcheon, I D

    2009-05-28

    The 'age' of a sample of uranium is an important aspect of a nuclear forensic investigation and of the attribution of the material to its source. To the extent that the sample obeys the standard rules of radiochronometry, then the production ages of even very recent material can be determined using the {sup 230}Th-{sup 234}U chronometer. These standard rules may be summarized as (a) the daughter/parent ratio at time=zero must be known, and (b) there has been no daughter/parent fractionation since production. For most samples of uranium, the 'ages' determined using this chronometer are semantically 'model-ages' because (a) some assumption of the initial {sup 230}Th content in the sample is required and (b) closed-system behavior is assumed. The uranium standard reference materials originally prepared and distributed by the former US National Bureau of Standards and now distributed by New Brunswick Laboratory as certified reference materials (NBS SRM = NBL CRM) are good candidates for samples where both rules are met. The U isotopic standards have known purification and production dates, and closed-system behavior in the solid form (U{sub 3}O{sub 8}) may be assumed with confidence. We present here {sup 230}Th-{sup 234}U model-ages for several of these standards, determined by isotope dilution mass spectrometry using a multicollector ICP-MS, and compare these ages with their known production history.

  5. Investigation of thermal management materials for automotive electronic control units

    International Nuclear Information System (INIS)

    Mallik, Sabuj; Ekere, Ndy; Best, Chris; Bhatti, Raj

    2011-01-01

    Today's electronics packages are smaller and more powerful than ever before. This leads to ever increasing thermal challenges for the systems designer. The automotive electronic control unit (ECU) package faces the same challenge of thermal management as the industry in general. This is coupled with the latest European Union legislation (Euro 6 standard) which forced the ECU manufacturers to completely re-design their ECU platform with improved hardware and software capability. This will result in increased power densities and therefore, the ability to dissipate heat will be a key factor. A higher thermal conductivity (TC) material for the ECU housing (than the currently used Aluminium) could improve heat dissipation from the ECU. This paper critically reviews the state-of-the-art in thermal management materials which may be applicable to an automotive ECU. This review shows that of the different materials currently available, the Al/SiC composites in particular have very good potential for automotive ECU application. In terms of metal composites processing, the liquid metal infiltration process is recommended as it has a lower processing cost and it also has the ability to produce near net-shape materials.

  6. Effective atomic numbers and electron density of dosimetric material

    Directory of Open Access Journals (Sweden)

    Kaginelli S

    2009-01-01

    Full Text Available A novel method for determination of mass attenuation coefficient of x-rays employing NaI (Tl detector system and radioactive sources is described.in this paper. A rigid geometry arrangement and gating of the spectrometer at FWHM position and selection of absorber foils are all done following detailed investigation, to minimize the effect of small angle scattering and multiple scattering on the mass attenuation coefficient, m/r, value. Firstly, for standardization purposes the mass attenuation coefficients of elemental foils such as Aluminum, Copper, Molybdenum, Tantalum and Lead are measured and then, this method is utilized for dosimetric interested material (sulfates. The experimental mass attenuation coefficient values are compared with the theoretical values to find good agreement between the theory and experiment within one to two per cent. The effective atomic numbers of the biological substitute material are calculated by sum rule and from the graph. The electron density of dosimetric material is calculated using the effective atomic number. The study has discussed in detail the attenuation coefficient, effective atomic number and electron density of dosimetric material/biological substitutes.

  7. Transmission electron microscopy a textbook for materials science

    CERN Document Server

    Williams, David B

    1996-01-01

    Electron microscopy has revolutionized our understanding the extraordinary intellectual demands required of the mi­ of materials by completing the processing-structure-prop­ croscopist in order to do the job properly: crystallography, erties links down to atomistic levels. It now is even possible diffraction, image contrast, inelastic scattering events, and to tailor the microstructure (and meso structure ) of materials spectroscopy. Remember, these used to be fields in them­ to achieve specific sets of properties; the extraordinary abili­ selves. Today, one has to understand the fundamentals ties of modem transmission electron microscopy-TEM­ of all of these areas before one can hope to tackle signifi­ instruments to provide almost all of the structural, phase, cant problems in materials science. TEM is a technique of and crystallographic data allow us to accomplish this feat. characterizing materials down to the atomic limits. It must Therefore, it is obvious that any curriculum in modem mate­ be use...

  8. Application of scandium oxide in an electron emission material

    International Nuclear Information System (INIS)

    Suqiu, Y.; Zhizheng, Z.; Yongde, W.

    1985-01-01

    Modern microwave devices impose a number of harsh requirements on the cathodes. For instance, they require cathodes having low working temperature, high emissive current density, slow evaporation rate of the emissive-active material, long lifetime, quick heating and so on. The commercial B-cathode is no longer able to meet these requirements completely. A scandate cathode may be a promising one for use in these devices. Adding rare-earth elements in the electron emission material has been reported in many papers. Based on a B-cathode we add a little amount of scandium oxide (about 3%) into emission material to manufacture a scandate cathode. The emission property of such a cathode has been improved greatly. If the composition is controlled correctly, the emission level of such a cathode may be five times more as high as the B-cathode

  9. Development of nanocomposite polymer materials for electrical and electronic applications

    International Nuclear Information System (INIS)

    Chine, Bruno

    2007-01-01

    Some results and experimental procedures of laboratory are reported in the frame of researches conducted for the development of new nanostructured composite materials. These new materials, which are constituted by an organic phase: the polymer and an inorganic phase: the silicate, are being strongly investigated nowadays so it is expected that they could provide, among other, better electrical insulation properties and flame-delay in electrical and electronic applications. The laboratory experimental work has been developed from two families of polymers, thermoplastics and thermosets and clays silicates providing lamellar type. There are now some preliminary results, such as obtaining thin films of these nanocomposite materials, their complete characterization by X-ray diffraction, scanning microscopy and thermogravimetric analysis, they do well to wait for future research activities. (author) [es

  10. Spatiotemporal Observation of Electron-Impact Dynamics in Photovoltaic Materials Using 4D Electron Microscopy

    KAUST Repository

    Shaheen, Basamat

    2017-05-17

    Understanding light-triggered charge carrier dynamics near photovoltaic-material surfaces and at interfaces has been a key element and one of the major challenges for the development of real-world energy devices. Visualization of such dynamics information can be obtained using the one-of-a-kind methodology of scanning ultrafast electron microscopy (S-UEM). Here, we address the fundamental issue of how the thickness of the absorber layer may significantly affect the charge carrier dynamics on material surfaces. Time-resolved snapshots indicate that the dynamics of charge carriers generated by electron impact in the electron-photon dynamical probing regime is highly sensitive to the thickness of the absorber layer, as demonstrated using CdSe films of different thicknesses as a model system. This finding not only provides the foundation for potential applications of S-UEM to a wide range of devices in the fields of chemical and materials research, but also has impact on the use and interpretation of electron beam-induced current for optimization of photoactive materials in these devices.

  11. Preparation and evaluation of reference materials for accountancy analysis. (1) Preparation and evaluation method

    International Nuclear Information System (INIS)

    Takamatsu, Mai; Kacchi, Tomokazu; Murakami, Toshiki; Ai, Hironobu; Sumi, Mika; Abe, Katsuo; Kageyama, Tomio; Nakazawa, Hiroaki

    2009-01-01

    Isotope dilution mass spectrometry method used for the accountancy analysis at nuclear fuel facilities requires the standard materials called LSD (Large Size Dried) spike. Generally, LSD spikes are prepared from certified reference materials (CRMs) which supplied from foreign laboratories. However, the difficulty of Pu CRM importation is increasing. It is important for safeguards to attain and continue high reliable accountancy analysis and stable securing of LSD spike is essential. Therefore, in order to conserve CRMs, several types of LSD spike were prepared under collaboration work between JAEA and JNFL, such as the amount of nuclear material in one LSD spike is decreased and others. Practical test with actual samples were performed at JNFL Rokkasho reprocessing plant, and those results were compared with the results obtained by using LSD spike which supplied from foreign laboratory. Preparation and verification analysis of LSD spikes and evaluation of uncertainty based on ISO-GUM will be presented. (author)

  12. Quality assessment of organic coffee beans for the preparation of a candidate reference material

    International Nuclear Information System (INIS)

    Tagliaferro, F.S.; Nadai Fernandes de, E.A.; Bacchi, M.A.

    2006-01-01

    A random sampling was carried out in the coffee beans collected for the preparation of the organic green coffee reference material in view of assessing the homogeneity and the presence of soil as impurity. Fifteen samples were taken for the between-sample homogeneity evaluation. One of the samples was selected and 10 test portions withdrawn for the within-sample homogeneity evaluation. Br, Ca, Co, Cs, Fe, K, Na, Rb, Sc and Zn were determined by instrumental neutron activation analysis (INAA). The F-test demonstrated that the material is homogeneous for Ca, Co, Cs, K and Sc, but not homogeneous for Br, Fe, Na, Rb and Zn. Results of terrigenous elements suggested negligible soil contamination in the raw material. (author)

  13. Reference Material Kydex(registered trademark)-100 Test Data Message for Flammability Testing

    Science.gov (United States)

    Engel, Carl D.; Richardson, Erin; Davis, Eddie

    2003-01-01

    The Marshall Space Flight Center (MSFC) Materials and Processes Technical Information System (MAPTIS) database contains, as an engineering resource, a large amount of material test data carefully obtained and recorded over a number of years. Flammability test data obtained using Test 1 of NASA-STD-6001 is a significant component of this database. NASA-STD-6001 recommends that Kydex 100 be used as a reference material for testing certification and for comparison between test facilities in the round-robin certification testing that occurs every 2 years. As a result of these regular activities, a large volume of test data is recorded within the MAPTIS database. The activity described in this technical report was undertaken to mine the database, recover flammability (Test 1) Kydex 100 data, and review the lessons learned from analysis of these data.

  14. Testing the homogeneity of candidate reference materials by solid sampling - AAS and INAA

    International Nuclear Information System (INIS)

    Rossbach, M.; Grobecker, K.-H.

    2002-01-01

    The necessity to quantify a natural material's homogeneity with respect to its elemental distribution prior to chemical analysis of a given aliquot is emphasised. Available instruments and methods to obtain the relevant information are described. Additionally the calculation of element specific, relative homogeneity factors, H E , and of a minimum sample mass M 5% to achieve 5% precision on a 95% confidence level is given. Especially, in the production and certification of Certified Reference Materials (CRMs) this characteristic information should be determined in order to provide the user with additional inherent properties of the CRM to enable more economical use of the expensive material and to evaluate further systematic bias of the applied analytical technique. (author)

  15. Performance of NAA methods in an International Interlaboratory Reference Material Characterization Campaign

    International Nuclear Information System (INIS)

    Ihnat, M.

    2000-01-01

    An extensive database of analytical results from a recent biological matrix Reference Material Characterization Campaign permitted an intercomparison of the performances of various methods among each other and with 'true' best estimate concentration values established for these materials. Six different variants of neutron activation analysis (NAA) methods were employed including: instrumental neutron activation analysis, instrumental neutron activation analysis with acid digestion, neutron activation analysis with radiochemical separation, neutron capture prompt gamma activation analysis, epithermal instrumental neutron activation analysis, and neutron activation analysis with preconcentration. The precision and accuracy performance of NAA-based analytical methods are compared with three other major techniques, atomic absorption spectrometry (AAS), atomic emission spectrometry (AES) and mass spectrometry (MS) for 28 elements in 10 natural matrix materials. (author)

  16. Homogeneity and evaluation of the new NIST leaf certified reference materials

    International Nuclear Information System (INIS)

    Becker, D.A.

    1990-01-01

    The NIST has produced and is in the process of certifying two new leaf CRMs, SRM1515 Apple Leaves and SRM 1547 Peach Leaves, as replacements for the no longer available NBS Orchard Leaves and the almost depleted Citrus Leaves. These two new materials have been processed and are being thoroughly evaluated and should provide the most advanced natural matrix botanical trace-element reference materials available. Caution should be used in determining a basis weight (drying) for these CRMs because of their very fine particle size. Homogeneity has been established by instrumental neutron activation analysis on both leaf materials for five elements, to date, to better than 1.5% (1 s) for 100-mg sample sizes

  17. Grain-size effects on PIXE and INAA analysis of IAEA-336 lichen reference material

    International Nuclear Information System (INIS)

    Marques, A.P.; Freitas, M.C.; Wolterbeek, H.Th.; Verburg, T.G.; Goeij, J.J.M. de

    2007-01-01

    IAEA-336 lichen certified reference material was used to compare outcomes from INAA and PIXE elemental analyses, in relationship with grain size. The IAEA material (grain size <125 μm) was ground and sieved through nylon nets with 64 μm, 41 μm and 20 μm pores. Particle sizes were determined by Laser Light Scattering technique: the data indicate that, after sieving, the IAEA-336 lichen reference material's particle size distribution follows a bimodal distribution, which is turning more and more monomodal after further fine sieving. Replicates of each fraction were analysed by INAA and PIXE. Results for Cl, K, Mn, Fe and Zn by both techniques were compared by application of z-values tested against the criterion vertical bar z vertical bar < 3 for approval of results at the 99.7% confidence level. Under the conditions of this study, the limited amount of lichen material as 'seen' in the PIXE analysis and the grain size distribution in the lichen material were no causes of measurable differences between the results of both techniques. However, fractionation into smaller grain sizes showed to be associated with lower element content, for Na, Cl, K, Mn and Sr even up to a factor of 2. The observed increases of the proportion of algae in the smaller grain-size fractions and the possible accumulation capacity for certain elements in the fungal part of the lichen may explain the observed phenomenon. The sieving process and consequently the discarding of part of the material have lead to a change of the properties of the original sample, namely algae/fungus percentage and elemental contents

  18. Catalog of NBS standard reference materials, 1975--76 edition. Special pub

    International Nuclear Information System (INIS)

    Seward, R.W.

    1975-06-01

    This Catalog lists and describes the Standard Reference Materials (SRM's), Research Materials (RM's), and General Materials (GM's) currently distributed by the National Bureau of Standards, as well as many of the materials currently in preparation. SRM's are used to calibrate measurement systems and to provide a central basis for uniformity and accuracy of measurement. The unit and quantity, the type, and the certified characterization are listed for each SRM, as well as directions for ordering. The RM's are not certified, but are issued to meet the needs of scientists engaged in materials research. RM's are issued with a 'Report of Investigation', the sole authority of which is the author of the report. The GM's are standardized by some agency other than NBS. NBS acts only as a distribution point and does not participate in the standardization of these materials. Announcements of new and renewal SRM's, RM's and GM's are made in the semi-annual supplements of this Catalog, SRM Price List, and in scientific and trade journals

  19. Flexible organic electronic devices: Materials, process and applications

    International Nuclear Information System (INIS)

    Logothetidis, Stergios

    2008-01-01

    The research for the development of flexible organic electronic devices (FEDs) is rapidly increasing worldwide, since FEDs will change radically several aspects of everyday life. Although there has been considerable progress in the area of flexible inorganic devices (a-Si or solution processed Si), there are numerous advances in the organic (semiconducting, conducting and insulating), inorganic and hybrid (organic-inorganic) materials that exhibit customized properties and stability, and in the synthesis and preparation methods, which are characterized by a significant amount of multidisciplinary efforts. Furthermore, the development and encapsulation of organic electronic devices onto flexible polymeric substrates by large-scale and low-cost roll-to-roll production processes will allow their market implementation in numerous application areas, including displays, lighting, photovoltaics, radio-frequency identification circuitry and chemical sensors, as well as to a new generation of modern exotic applications. In this work, we report on some of the latest advances in the fields of polymeric substrates, hybrid barrier layers, inorganic and organic materials to be used as novel active and functional thin films and nanomaterials as well as for the encapsulation of the materials components for the production of FEDs (flexible organic light-emitting diodes, and organic photovoltaics). Moreover, we will emphasize on the real-time optical monitoring and characterization of the growing films onto the flexible polymeric substrates by spectroscopic ellipsometry methods. Finally, the potentiality for the in-line characterization processes for the development of organic electronics materials will be emphasized, since it will also establish the framework for the achievement of the future scientific and technological breakthroughs

  20. Reference Materials for Trace Element Microanalysis of Carbonates by SIMS and other Mass Spectrometric Techniques

    Science.gov (United States)

    Layne, G. D.

    2009-12-01

    Today, many areas of geochemical research utilize microanalytical determinations of trace elements in carbonate minerals. In particular, there has been an explosion in the application of Secondary Ion Mass Spectrometry (SIMS) to studies of marine biomineralization. SIMS provides highly precise determinations of Mg and Sr at the concentration levels normally encountered in corals, mollusks or fish otoliths. It is also a highly effective means for determining a wide range of other trace elements at ppm levels (e.g., Na, Fe, Mn, Ba, REE, Pb, Th, and U) in a variety of naturally occurring calcite and aragonite matrices - and so is potentially valuable in studies of diagenesis, hydrothermal fluids and carbonatitic magmas. For SIMS, modest time per spot (often sputtered ion yields of most elements with the major element composition of the sample matrix, accuracy of SIMS depends intimately on matrix-matched solid reference materials. Despite its rapidly increasing use for trace element analyses of carbonates, there remains a dearth of certified reference materials suitable for calibrating SIMS. The pressed powders used by some analysts to calibrate LA-ICP-MS do not perform well for SIMS - they are not perfectly dense or homogeneous to the desired level at the micron scale of sampling. Further, they often prove incompatible with the sample high vacuum compatibility requirement for stable SIMS analysis (10-8 to 10-9 torr). Some naturally occurring calcite has apparent utility as a reference material. For example, equigranular calcite from some zones of carbonatite intrusions (sovites) and recrystallized calcites from highly metamorphosed metallic ore deposits. Most calcite marbles, though possibly appropriate as Sr standards, show substantial inhomogeneity in Mg, Mn and Ba. Some hydrothermal “Iceland Spar” calcite may prove useful as a reference for extremely low concentrations of Mg, Sr and Ba. The best carbonatitic calcites currently in use appear homogeneous to

  1. NAA study on homogeneity of reference materials and their suitability for microanalytical techniques

    International Nuclear Information System (INIS)

    Dybczynski, R.; Danko, B.; Polkowska-Motrenko, H.

    2000-01-01

    Homogeneity of the existing (Virginia Tobacco Leaves CTA-VTL-2 (ICHTJ), Apatite Concentrate CTA-AC-1 (ICHTJ), Fine Fly Ash CTA-FFA-1 (ICHTJ)) and candidate certified reference materials (CRMs) (IAEA-338 Lichen, IAEA-413 Algae, Spruce Shoots RMF II (Germany)) was studied by neutron activation analysis (NAA). Several samples of small mass (ca. 1 or 10 mg) taken from various containers were analyzed by instrumental NAA and the results for several elements were compared by Fishers's test and t-test with analogous series of results for samples taken from one container. In the second approach, sampling variance was estimated for some elements from overall variance and the components of analytical variance. The results were interpreted with the aid of Ingamells' sampling constant. Particle size distribution of the reference materials was also measured by several techniques. In addition quantitative determinations for some elements were performed and results compared with the certified values. The results of the present study were discussed with reference to suitability of CRMs to microanalytical techniques. It was pointed out that the term 'microanalysis' itself is not always unequivocally understood and used. (author)

  2. The use of reference materials in quality assurance programmes in food microbiology laboratories.

    Science.gov (United States)

    In't Veld, P H

    1998-11-24

    Nine different reference materials (RMs) for use in food and water microbiology have been developed with the support of the European Commission (EC). The production process of RMs is based on spray drying bacteria suspended in milk. The highly contaminated milk powder (HCMP) obtained is mixed with sterile milk powder to achieve the desired level of contamination and is subsequently filled into gelatine capsules. The HCMP may need to be stabilised by storage for more than a year before a stable RM can be prepared. The HCMP are mixed with sterile milk powder using a pestle and mortar in order to produce homogeneous RMs. For routine use of RMs Shewhart control charts can be produced. Based on log10 transformed counts, control limits are calculated. Rules for the interpretation of results facilitate the detection of out of control situations. Besides RMs there are also CRMs (Certified Reference Materials) that are certified by the EC Community Bureau of Reference (BCR) and are intended for occasional use. Based on the BCR certificate, user tables are produced presenting the 95% confidence limits for the number of capsules likely to be examined in practice. Also power analysis is made to indicate the minimum difference between the certified value and the observed geometric mean value in relation to the number of capsules examined.

  3. Design of materials configurations for enhanced phononic and electronic properties

    Science.gov (United States)

    Daraio, Chiara

    The discovery of novel nonlinear dynamic and electronic phenomena is presented for the specific cases of granular materials and carbon nanotubes. This research was conducted for designing and constructing optimized macro-, micro- and nano-scale structural configurations of materials, and for studying their phononic and electronic behavior. Variation of composite arrangements of granular elements with different elastic properties in a linear chain-of-sphere, Y-junction or 3-D configurations led to a variety of novel phononic phenomena and interesting physical properties, which can be potentially useful for security, communications, mechanical and biomedical engineering applications. Mechanical and electronic properties of carbon nanotubes with different atomic arrangements and microstructures were also investigated. Electronic properties of Y-junction configured carbon nanotubes exhibit an exciting transistor switch behavior which is not seen in linear configuration nanotubes. Strongly nonlinear materials were designed and fabricated using novel and innovative concepts. Due to their unique strongly nonlinear and anisotropic nature, novel wave phenomena have been discovered. Specifically, violations of Snell's law were detected and a new mechanism of wave interaction with interfaces between NTPCs (Nonlinear Tunable Phononic Crystals) was established. Polymer-based systems were tested for the first time, and the tunability of the solitary waves speed was demonstrated. New materials with transformed signal propagation speed in the manageable range of 10-100 m/s and signal amplitude typical for audible speech have been developed. The enhancing of the mitigation of solitary and shock waves in 1-D chains were demonstrated and a new protective medium was designed for practical applications. 1-D, 2-D and 3-D strongly nonlinear system have been investigated providing a broad impact on the whole area of strongly nonlinear wave dynamics and creating experimental basis for new

  4. Electronic materials with a wide band gap: recent developments

    Directory of Open Access Journals (Sweden)

    Detlef Klimm

    2014-09-01

    Full Text Available The development of semiconductor electronics is reviewed briefly, beginning with the development of germanium devices (band gap Eg = 0.66 eV after World War II. A tendency towards alternative materials with wider band gaps quickly became apparent, starting with silicon (Eg = 1.12 eV. This improved the signal-to-noise ratio for classical electronic applications. Both semiconductors have a tetrahedral coordination, and by isoelectronic alternative replacement of Ge or Si with carbon or various anions and cations, other semiconductors with wider Eg were obtained. These are transparent to visible light and belong to the group of wide band gap semiconductors. Nowadays, some nitrides, especially GaN and AlN, are the most important materials for optical emission in the ultraviolet and blue regions. Oxide crystals, such as ZnO and β-Ga2O3, offer similarly good electronic properties but still suffer from significant difficulties in obtaining stable and technologically adequate p-type conductivity.

  5. Electron tomography of porous materials and magnetic nanoparticles

    International Nuclear Information System (INIS)

    Uusimäki, T.

    2015-01-01

    Electron tomography, as carried out in a transmission electron microscope is a method to reveal the three dimensional structure of the sample at the nanometer scale. It is based on tilting the sample and recording subsequent images at different projections angles. Using specific reconstruction algorithms the density distribution of the sample can then be reproduced. In this thesis, electron tomography has been implemented for material science specimens and more rigorously to porous media infiltrated with magnetic nanoparticles. The volume and spatial distribution along with the knowledge of the demagnetizing factors were then used within a magnetic Monte Carlo simulation to predict the magnetic response of the nanoparticle assembly. The local curvature of nanoparticles within the template, known to be a critical geometrical parameter influencing material properties, was extracted with two distinctive methods. Furthermore, new capabilities needed for image analysis and processing of the tilt series had to be implemented for improved alignments and segmentation. A new method to align the tilt series without depending on markers was written for obtaining high quality reconstructions. Also a comparison was made between different scanning TEM acquisition modes such as incoherent bright field and high angle annular dark field imaging modes with respect to resolution and contrast changes. (author) [de

  6. DEVELOPMENT OF THE REFERENCE MATERIALS PRODUCTION BRANCH IN THE JOINT STOCK COMPANY "THE GULIDOV KRASNOYARSK NON-FERROUS METALS PLANT"

    Directory of Open Access Journals (Sweden)

    K. A. Shatnykh

    2015-01-01

    Full Text Available The article deals with the development of the branch for the reference materials production in the Joint Stock Company "The Gulidov Krasnoyarsk Non-Ferrous Metals Plant" (JSC "Krastsvetmet". Here the most important workings for reference materials including the work for the London precious metal exchange, current and future works are stated.

  7. Discussion on the interrelationship between structural, optical, electronic and elastic properties of materials

    International Nuclear Information System (INIS)

    Aly, Kamal A.

    2015-01-01

    Highlights: • The calculated values of bulk modulus in Reddy et al. [1] are now recalculated correctly. • Eq. (11) suggested by Reddy et al. [1] is not suitable to calculate the bulk modulus, B, for any element or material. • Eq. (12) in Ref. [1] is suitable to calculate, B, for all elements and materials except the underlined materials in Table 4. • All values of the electronic polarizability have been recalculated by different methods. • The bulk modulus, B, and microhardness parameter, H are different; Eq. (8) gives the relation between B and H. - Abstract: In reference Reddy et al. (2009) the correlations between energy gap, optical electronegativity and electronic polarizability for different materials have been studied. The authors of this paper (Reddy et al., 2009) aimed to make extinction or complete some previous works (Bahadur and Mishra, 2013; Reddy et al., 1999, 2000, 1998, 2005, 2008; Reddy and Nazeer Ahammed, 1996; Oshcherin, 1979; Neumann, 1983, 1987; Deus and Schneider; 1985; Deus et al., 1983; Kumar et al. 1992). However, this paper (Reddy et al., 2009) contains many fundamental errors in the calculation of bulk modulus, especially Tables 4–6. As a result, all the obtained values of the bulk modulus and consequently the electronic polarizability are incorrect. Moreover in Table 4 (Reddy et al., 2009), the bulk modulus of II−VI group semiconductors have been calculated by substituting the values of the band gap, E g , into Eq. (11) (B = 14.91 E g + 23.3). The obtained values of B using Eq. (11) are conflicted with that calculated values of B based on the electronegativity and the published previously data. Therefore Eq. (11) in reference Reddy et al. (2009) is not suitable for calculating the values of B for any element or materials. When I recalculated the values of B for all materials in Tables 1 and 4–6 in paper (Reddy et al., 2009) using Eq. (12), I found that, Eq. (12) gives acceptable values of B for all materials except the

  8. Bias in the absorption coefficient determination of a fluorescent dye, standard reference material 1932 fluorescein solution

    International Nuclear Information System (INIS)

    DeRose, Paul C.; Kramer, Gary W.

    2005-01-01

    The absorption coefficient of standard reference material[registered] (SRM[registered]) 1932, fluorescein in a borate buffer solution (pH=9.5) has been determined at λ=488.0, 490.0, 490.5 and 491.0 nm using the US national reference UV/visible spectrophotometer. The purity of the fluorescein was determined to be 97.6% as part of the certification of SRM 1932. The solution measured was prepared gravimetrically by diluting SRM 1932 with additional borate buffer. The value of the absorption coefficient was corrected for bias due to fluorescence that reaches the detector and for dye purity. Bias due to fluorescence was found to be on the order of -1% for both monochromatic and polychromatic (e.g., diode-array based) spectrophotometers

  9. Standard reference material certification: contribution of NAA with a TRIGA reactor

    International Nuclear Information System (INIS)

    Orvini, E.; Speziali, M.; Salvini, A.; Herborg, C.

    2002-01-01

    Pavia has cooperative links with the major international agencies devoted to the certification of SRMs or CRMs as the Bureau Communautaire de Reference (BCR), the European Institute for Reference Materials and Measurement (IRMM), the USA National Institute of Standards and Technology (NIST) and the International Atomic Energy Agency (IAEA). During these cooperative works, a large amount of analytical data obtained with NAA has been compared, and meaningful methodological information achieved with respect to accuracy and precision in the analysis of several elements at different concentrations in various matrices. Analytical data on As, Cd, Cr, Co, Cu, Cs, Fe, Zn, K, Sc, U, Th, Al, Sb, Mn, V, Hg, Sr, Rb, Se,Pt, all the Rare Earths and halogens Br, Cl, I, have been obtained and contributed for the final certification

  10. Uncertainty evaluation in normalization of isotope delta measurement results against international reference materials.

    Science.gov (United States)

    Meija, Juris; Chartrand, Michelle M G

    2018-01-01

    Isotope delta measurements are normalized against international reference standards. Although multi-point normalization is becoming a standard practice, the existing uncertainty evaluation practices are either undocumented or are incomplete. For multi-point normalization, we present errors-in-variables regression models for explicit accounting of the measurement uncertainty of the international standards along with the uncertainty that is attributed to their assigned values. This manuscript presents framework to account for the uncertainty that arises due to a small number of replicate measurements and discusses multi-laboratory data reduction while accounting for inevitable correlations between the laboratories due to the use of identical reference materials for calibration. Both frequentist and Bayesian methods of uncertainty analysis are discussed.

  11. Report of the consultants meeting on proper use of reference and control materials

    International Nuclear Information System (INIS)

    2002-01-01

    Quality control in analytical laboratories as a basis of a complete quality system needs still to be developed in many Member States. To support the dissemination of information in this field a consultants meeting on 'Proper Use of Reference and Quality Control Materials' was held at the IAEA Headquarters, Vienna, from 13 to 17 August 2001. The experts convened with the objective to prepare a TECDOC to advise analytical laboratories in Member States on the correct use of Certified Reference Materials (CRMs) for Quality Control purposes and give practical recommendations to expand this concept to in-house Quality Control Materials (QCMs). In view of the existing literature in this field an urgent need for a practical guidebook for the preparation and application of cost effective and matrix matching QCMs was identified and the experts tried to fill this gap from their relevant experience. One and a half days of lecturing was followed by intensive discussion and brain storming to create a list of key words, which were structured in a logical order to provide a frame for the projected document. Responsibilities were assigned and deadlines fixed for the submission of the full text. (author)

  12. Certified Reference Material IAEA-448: Soil from Oil Field Contaminated with Technically Enhanced Radium-226

    International Nuclear Information System (INIS)

    2013-01-01

    To ensure reliable evaluation of potential radiological hazards and proper decision making related to radiation protection measures, the IAEA, through the IAEA Environment Laboratories, supports Member State laboratories in their efforts to maintain readiness and to improve the quality of analytical results. It does so by producing reference materials, by developing standardized methods for sample collection and analysis, and by conducting interlaboratory comparisons and proficiency tests as tools for external quality control of analytical results. The problem of naturally occurring radioactive material (NORM) contamination is known to be widespread, occurring in oil and gas production facilities throughout the world. It has become a subject of attention in many IAEA Member States. In response to this radiological concern, facilities in many Member States have been characterizing the nature and extent of NORM in oil and gas installations and in the surrounding environment, evaluating the potential for exposure to workers and the public, and developing methods for properly managing these relatively high massic activity residues. Within this context, the IAEA Environment Laboratories, in cooperation with the Atomic Energy Commission of Syria, an IAEA Collaborating Centre, have prepared a new certified reference material of soil contaminated with NORM, identified as IAEA-448, certified for the massic activity of 226Ra. This report presents the methodologies used for the production and certification of IAEA-448

  13. Results of a Saxitoxin Proficiency Test Including Characterization of Reference Material and Stability Studies

    Directory of Open Access Journals (Sweden)

    Kirsi Harju

    2015-11-01

    Full Text Available A saxitoxin (STX proficiency test (PT was organized as part of the Establishment of Quality Assurance for the Detection of Biological Toxins of Potential Bioterrorism Risk (EQuATox project. The aim of this PT was to provide an evaluation of existing methods and the European laboratories’ capabilities for the analysis of STX and some of its analogues in real samples. Homogenized mussel material and algal cell materials containing paralytic shellfish poisoning (PSP toxins were produced as reference sample matrices. The reference material was characterized using various analytical methods. Acidified algal extract samples at two concentration levels were prepared from a bulk culture of PSP toxins producing dinoflagellate Alexandrium ostenfeldii. The homogeneity and stability of the prepared PT samples were studied and found to be fit-for-purpose. Thereafter, eight STX PT samples were sent to ten participating laboratories from eight countries. The PT offered the participating laboratories the possibility to assess their performance regarding the qualitative and quantitative detection of PSP toxins. Various techniques such as official Association of Official Analytical Chemists (AOAC methods, immunoassays, and liquid chromatography-mass spectrometry were used for sample analyses.

  14. Development of Candidate Reference Materials of Endosulfan Sulfate and Bifenthrin in Black Tea

    Directory of Open Access Journals (Sweden)

    Nurhani Aryana

    2016-03-01

    Full Text Available The candidate reference materials of endosulfan sulfate and bifenthrin in black tea have been developed according to the requirements of ISO Guide 34 and 35. Preparation of candidate material includes grinding and sieving of the black tea leaves, spiking the black tea powder by both analytes, homogenization, and bottling. Homogeneity and short-term stability test were performed using a GC-µECD instrument. Meanwhile, the characterization was carried out by a collaborative study using both of GC-µECD and GC-MS instruments. The uncertainty budget was evaluated from sample inhomogeneity, short-term instability and variability in the characterization procedure. In a dry mass fraction, endosulfan sulfate was assigned to be 491 µg kg-1 with a relative expanded uncertainty of ± 33.2%, and bifenthrin was assigned to be 937 µg kg-1 with a relative expanded uncertainty of ± 18.5%. The candidate reference materials are aimed to support the need of matrix CRM especially for the measurement of pesticide residue for quality assurance work done by laboratories in Indonesia.

  15. Multivariate methods for analysis of environmental reference materials using laser-induced breakdown spectroscopy

    Directory of Open Access Journals (Sweden)

    Shikha Awasthi

    2017-06-01

    Full Text Available Analysis of emission from laser-induced plasma has a unique capability for quantifying the major and minor elements present in any type of samples under optimal analysis conditions. Chemometric techniques are very effective and reliable tools for quantification of multiple components in complex matrices. The feasibility of laser-induced breakdown spectroscopy (LIBS in combination with multivariate analysis was investigated for the analysis of environmental reference materials (RMs. In the present work, different (Certified/Standard Reference Materials of soil and plant origin were analyzed using LIBS and the presence of Al, Ca, Mg, Fe, K, Mn and Si were identified in the LIBS spectra of these materials. Multivariate statistical methods (Partial Least Square Regression and Partial Least Square Discriminant Analysis were employed for quantitative analysis of the constituent elements using the LIBS spectral data. Calibration models were used to predict the concentrations of the different elements of test samples and subsequently, the concentrations were compared with certified concentrations to check the authenticity of models. The non-destructive analytical method namely Instrumental Neutron Activation Analysis (INAA using high flux reactor neutrons and high resolution gamma-ray spectrometry was also used for intercomparison of results of two RMs by LIBS.

  16. Short-term stability test for thorium soil candidate a reference material

    Energy Technology Data Exchange (ETDEWEB)

    Clain, Almir F.; Fonseca, Adelaide M.G.; Dantas, Vanessa V.D.B.; Braganca, Maura J.C.; Souza, Poliana S., E-mail: almir@ird.gov.br, E-mail: adelaide@ird.gov.br, E-mail: vanessa@ird.gov.br, E-mail: maura@ird.gov.br, E-mail: poliana@bolsista.ird.gov.br [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2015-07-01

    This work describes a methodology to determine the soil short-term stability after the steps of production in laboratory. The short-term stability of the soil is an essential property to be determined in order to producing a reference material. The soil is a candidate of reference material for chemical analysis of thorium with metrological traceability to be used in environmental analysis, equipment calibration, validation methods, and quality control. A material is considered stable in a certain temperature if the property of interest does not change with time, considering the analytical random fluctuations. Due to this, the angular coefficient from the graphic of Th concentration versus elapsed time must be near to zero. The analytical determinations of thorium concentration were performed by Instrumental Neutron activation Analysis. The slopes and their uncertainties were obtained from the regression lines at temperatures of 20 deg C and 60 deg C, with control temperature of -20 deg C. From the obtained data a t-test was applied. In both temperatures the calculated t-value was lower than the critical value, so we can conclude with 95% confidence level that no significant changes happened during the period studied concerning thorium concentration in soil at temperatures of 20 deg C and 60 deg C, showing stability at these temperatures. (author)

  17. Evaluation of a fungal collection as certified reference material producer and as a biological resource center

    Directory of Open Access Journals (Sweden)

    Tatiana Forti

    2016-06-01

    Full Text Available Abstract Considering the absence of standards for culture collections and more specifically for biological resource centers in the world, in addition to the absence of certified biological material in Brazil, this study aimed to evaluate a Fungal Collection from Fiocruz, as a producer of certified reference material and as Biological Resource Center (BRC. For this evaluation, a checklist based on the requirements of ABNT ISO GUIA34:2012 correlated with the ABNT NBR ISO/IEC17025:2005, was designed and applied. Complementing the implementation of the checklist, an internal audit was performed. An evaluation of this Collection as a BRC was also conducted following the requirements of the NIT-DICLA-061, the Brazilian internal standard from Inmetro, based on ABNT NBR ISO/IEC 17025:2005, ABNT ISO GUIA 34:2012 and OECD Best Practice Guidelines for BRCs. This was the first time that the NIT DICLA-061 was applied in a culture collection during an internal audit. The assessments enabled the proposal for the adequacy of this Collection to assure the implementation of the management system for their future accreditation by Inmetro as a certified reference material producer as well as its future accreditation as a Biological Resource Center according to the NIT-DICLA-061.

  18. Evaluation of a fungal collection as certified reference material producer and as a biological resource center.

    Science.gov (United States)

    Forti, Tatiana; Souto, Aline da S S; do Nascimento, Carlos Roberto S; Nishikawa, Marilia M; Hubner, Marise T W; Sabagh, Fernanda P; Temporal, Rosane Maria; Rodrigues, Janaína M; da Silva, Manuela

    2016-01-01

    Considering the absence of standards for culture collections and more specifically for biological resource centers in the world, in addition to the absence of certified biological material in Brazil, this study aimed to evaluate a Fungal Collection from Fiocruz, as a producer of certified reference material and as Biological Resource Center (BRC). For this evaluation, a checklist based on the requirements of ABNT ISO GUIA34:2012 correlated with the ABNT NBR ISO/IEC17025:2005, was designed and applied. Complementing the implementation of the checklist, an internal audit was performed. An evaluation of this Collection as a BRC was also conducted following the requirements of the NIT-DICLA-061, the Brazilian internal standard from Inmetro, based on ABNT NBR ISO/IEC 17025:2005, ABNT ISO GUIA 34:2012 and OECD Best Practice Guidelines for BRCs. This was the first time that the NIT DICLA-061 was applied in a culture collection during an internal audit. The assessments enabled the proposal for the adequacy of this Collection to assure the implementation of the management system for their future accreditation by Inmetro as a certified reference material producer as well as its future accreditation as a Biological Resource Center according to the NIT-DICLA-061. Copyright © 2016 Sociedade Brasileira de Microbiologia. Published by Elsevier Editora Ltda. All rights reserved.

  19. Report of the consultants meeting on proper use of reference and control materials

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2002-07-01

    Quality control in analytical laboratories as a basis of a complete quality system needs still to be developed in many Member States. To support the dissemination of information in this field a consultants meeting on 'Proper Use of Reference and Quality Control Materials' was held at the IAEA Headquarters, Vienna, from 13 to 17 August 2001. The experts convened with the objective to prepare a TECDOC to advise analytical laboratories in Member States on the correct use of Certified Reference Materials (CRMs) for Quality Control purposes and give practical recommendations to expand this concept to in-house Quality Control Materials (QCMs). In view of the existing literature in this field an urgent need for a practical guidebook for the preparation and application of cost effective and matrix matching QCMs was identified and the experts tried to fill this gap from their relevant experience. One and a half days of lecturing was followed by intensive discussion and brain storming to create a list of key words, which were structured in a logical order to provide a frame for the projected document. Responsibilities were assigned and deadlines fixed for the submission of the full text. (author)

  20. Short-term stability test for thorium soil candidate a reference material

    International Nuclear Information System (INIS)

    Clain, Almir F.; Fonseca, Adelaide M.G.; Dantas, Vanessa V.D.B.; Braganca, Maura J.C.; Souza, Poliana S.

    2015-01-01

    This work describes a methodology to determine the soil short-term stability after the steps of production in laboratory. The short-term stability of the soil is an essential property to be determined in order to producing a reference material. The soil is a candidate of reference material for chemical analysis of thorium with metrological traceability to be used in environmental analysis, equipment calibration, validation methods, and quality control. A material is considered stable in a certain temperature if the property of interest does not change with time, considering the analytical random fluctuations. Due to this, the angular coefficient from the graphic of Th concentration versus elapsed time must be near to zero. The analytical determinations of thorium concentration were performed by Instrumental Neutron activation Analysis. The slopes and their uncertainties were obtained from the regression lines at temperatures of 20 deg C and 60 deg C, with control temperature of -20 deg C. From the obtained data a t-test was applied. In both temperatures the calculated t-value was lower than the critical value, so we can conclude with 95% confidence level that no significant changes happened during the period studied concerning thorium concentration in soil at temperatures of 20 deg C and 60 deg C, showing stability at these temperatures. (author)

  1. Flexible diodes for radio frequency (RF) electronics: a materials perspective

    KAUST Repository

    Semple, James

    2017-10-30

    Over the last decade, there has been increasing interest in transferring the research advances in radiofrequency (RF) rectifiers, the quintessential element of the chip in the RF identification (RFID) tags, obtained on rigid substrates onto plastic (flexible) substrates. The growing demand for flexible RFID tags, wireless communications applications and wireless energy harvesting systems that can be produced at a low-cost is a key driver for this technology push. In this topical review, we summarise recent progress and status of flexible RF diodes and rectifying circuits, with specific focus on materials and device processing aspects. To this end, different families of materials (e.g. flexible silicon, metal oxides, organic and carbon nanomaterials), manufacturing processes (e.g. vacuum and solution processing) and device architectures (diodes and transistors) are compared. Although emphasis is placed on performance, functionality, mechanical flexibility and operating stability, the various bottlenecks associated with each technology are also addressed. Finally, we present our outlook on the commercialisation potential and on the positioning of each material class in the RF electronics landscape based on the findings summarised herein. It is beyond doubt that the field of flexible high and ultra-high frequency rectifiers and electronics as a whole will continue to be an active area of research over the coming years.

  2. Flexible diodes for radio frequency (RF) electronics: a materials perspective

    KAUST Repository

    Semple, James; Georgiadou, Dimitra G; Wyatt-Moon, Gwenhivir; Gelinck, Gerwin; Anthopoulos, Thomas D.

    2017-01-01

    Over the last decade, there has been increasing interest in transferring the research advances in radiofrequency (RF) rectifiers, the quintessential element of the chip in the RF identification (RFID) tags, obtained on rigid substrates onto plastic (flexible) substrates. The growing demand for flexible RFID tags, wireless communications applications and wireless energy harvesting systems that can be produced at a low-cost is a key driver for this technology push. In this topical review, we summarise recent progress and status of flexible RF diodes and rectifying circuits, with specific focus on materials and device processing aspects. To this end, different families of materials (e.g. flexible silicon, metal oxides, organic and carbon nanomaterials), manufacturing processes (e.g. vacuum and solution processing) and device architectures (diodes and transistors) are compared. Although emphasis is placed on performance, functionality, mechanical flexibility and operating stability, the various bottlenecks associated with each technology are also addressed. Finally, we present our outlook on the commercialisation potential and on the positioning of each material class in the RF electronics landscape based on the findings summarised herein. It is beyond doubt that the field of flexible high and ultra-high frequency rectifiers and electronics as a whole will continue to be an active area of research over the coming years.

  3. Virtual screening of electron acceptor materials for organic photovoltaic applications

    International Nuclear Information System (INIS)

    D Halls, Mathew; Giesen, David J; Goldberg, Alexander; Djurovich, Peter J; Sommer, Jonathan; McAnally, Eric; Thompson, Mark E

    2013-01-01

    Virtual screening involves the generation of structure libraries, automated analysis to predict properties related to application performance and subsequent screening to identify lead systems and estimate critical structure–property limits across a targeted chemical design space. This approach holds great promise for informing experimental discovery and development efforts for next-generation materials, such as organic semiconductors. In this work, the virtual screening approach is illustrated for nitrogen-substituted pentacene molecules to identify systems for development as electron acceptor materials for use in organic photovoltaic (OPV) devices. A structure library of tetra-azapentacenes (TAPs) was generated by substituting four nitrogens for CH at 12 sites on the pentacene molecular framework. Molecular properties (e.g. E LUMO , E g and μ) were computed for each candidate structure using hybrid DFT at the B3LYP/6-311G** level of theory. The resulting TAPs library was then analyzed with respect to intrinsic properties associated with OPV acceptor performance. Marcus reorganization energies for charge transport for the most favorable TAP candidates were then calculated to further determine suitability as OPV electron acceptors. The synthesis, characterization and OPV device testing of TAP materials is underway, guided by these results. (paper)

  4. Flexible diodes for radio frequency (RF) electronics: a materials perspective

    Science.gov (United States)

    Semple, James; Georgiadou, Dimitra G.; Wyatt-Moon, Gwenhivir; Gelinck, Gerwin; Anthopoulos, Thomas D.

    2017-12-01

    Over the last decade, there has been increasing interest in transferring the research advances in radiofrequency (RF) rectifiers, the quintessential element of the chip in the RF identification (RFID) tags, obtained on rigid substrates onto plastic (flexible) substrates. The growing demand for flexible RFID tags, wireless communications applications and wireless energy harvesting systems that can be produced at a low-cost is a key driver for this technology push. In this topical review, we summarise recent progress and status of flexible RF diodes and rectifying circuits, with specific focus on materials and device processing aspects. To this end, different families of materials (e.g. flexible silicon, metal oxides, organic and carbon nanomaterials), manufacturing processes (e.g. vacuum and solution processing) and device architectures (diodes and transistors) are compared. Although emphasis is placed on performance, functionality, mechanical flexibility and operating stability, the various bottlenecks associated with each technology are also addressed. Finally, we present our outlook on the commercialisation potential and on the positioning of each material class in the RF electronics landscape based on the findings summarised herein. It is beyond doubt that the field of flexible high and ultra-high frequency rectifiers and electronics as a whole will continue to be an active area of research over the coming years.

  5. Nanomaterials for environmental studies: Classification, reference material issues, and strategies for physico-chemical characterisation

    Energy Technology Data Exchange (ETDEWEB)

    Stone, Vicki, E-mail: v.stone@napier.ac.uk [School of Life Sciences, Edinburgh Napier University, 10 Colinton Road, Edinburgh EH10 5DT (United Kingdom); Nowack, Bernd [Materials, Products and the Environment Group, Empa - Swiss Federal Laboratories for Materials Testing and Research, Lerchenfeldstrasse 5 CH - 9014 St. Gallen (Switzerland); Baun, Anders [Department of Environmental Engineering, Technical University of Denmark, NanoDTU, Building 113, 2800 Kgs. Lyngby (Denmark); Brink, Nico van den [Alterra, P.O. Box 47, 6700 AA Wageningen (Netherlands); Kammer, Frank von der [Department of Environmental Geosciences, Vienna University, Althanstrasse 14, Wien 1090 (Austria); Dusinska, Maria [Health Effects Laboratory, Centre for Ecological Economics, Norwegian Institute for Air Research (NILU), Instituttveien, 18, 2027 Kjeller (Norway); Handy, Richard [University of Plymouth, Davy Building, Drake Circus, Plymouth PL4 8AA (United Kingdom); Hankin, Steven [Institute of Occupational Medicine, Research Avenue North, Riccarton, Edinburgh EH14 4AP (United Kingdom); Hasselloev, Martin [Department of Chemistry, Environmental Nanoparticle Research Group, Goeteborg University, SE-412 96 Goeteborg (Sweden); Joner, Erik [Bioforsk Soil and Environment, Fredrik A Dahls vei 20, N-1432 Aas (Norway); Fernandes, Teresa F. [School of Life Sciences, Edinburgh Napier University, 10 Colinton Road, Edinburgh EH10 5DT (United Kingdom)

    2010-03-01

    NanoImpactNet is a European Commission Framework Programme 7 (FP7) funded project that provides a forum for the discussion of current opinions on nanomaterials in relation to human and environmental issues. In September 2008, in Zurich, a NanoImpactNet environmental workshop focused on three key questions: 1.What properties should be characterised for nanomaterials used in environmental and ecotoxicology studies? 2.What reference materials should be developed for use in environmental and ecotoxicological studies? 3.Is it possible to group different nanomaterials into categories for consideration in environmental studies? Such questions have been, at least partially, addressed by other projects/workshops especially in relation to human health effects. Such projects provide a useful basis on which this workshop was based, but in this particular case these questions were reformulated in order to focus specifically on environmental studies. The workshop participants, through a series of discussion and reflection sessions, generated the conclusions listed below. The physicochemical characterisation information identified as important for environmental studies included measures of aggregation/agglomeration/dispersability, size, dissolution (solubility), surface area, surface charge, surface chemistry/composition, with the assumption that chemical composition would already be known. There is a need to have test materials for ecotoxicology, and several substances are potentially useful, including TiO{sub 2} nanoparticles, polystyrene beads labelled with fluorescent dyes, and silver nanoparticles. Some of these test materials could then be developed into certified reference materials over time. No clear consensus was reached regarding the classification of nanomaterials into categories to aid environmental studies, except that a chemistry-based classification system was a reasonable starting point, with some modifications. It was suggested, that additional work may be

  6. Nanomaterials for environmental studies: Classification, reference material issues, and strategies for physico-chemical characterisation

    International Nuclear Information System (INIS)

    Stone, Vicki; Nowack, Bernd; Baun, Anders; Brink, Nico van den; Kammer, Frank von der; Dusinska, Maria; Handy, Richard; Hankin, Steven; Hasselloev, Martin; Joner, Erik; Fernandes, Teresa F.

    2010-01-01

    NanoImpactNet is a European Commission Framework Programme 7 (FP7) funded project that provides a forum for the discussion of current opinions on nanomaterials in relation to human and environmental issues. In September 2008, in Zurich, a NanoImpactNet environmental workshop focused on three key questions: 1.What properties should be characterised for nanomaterials used in environmental and ecotoxicology studies? 2.What reference materials should be developed for use in environmental and ecotoxicological studies? 3.Is it possible to group different nanomaterials into categories for consideration in environmental studies? Such questions have been, at least partially, addressed by other projects/workshops especially in relation to human health effects. Such projects provide a useful basis on which this workshop was based, but in this particular case these questions were reformulated in order to focus specifically on environmental studies. The workshop participants, through a series of discussion and reflection sessions, generated the conclusions listed below. The physicochemical characterisation information identified as important for environmental studies included measures of aggregation/agglomeration/dispersability, size, dissolution (solubility), surface area, surface charge, surface chemistry/composition, with the assumption that chemical composition would already be known. There is a need to have test materials for ecotoxicology, and several substances are potentially useful, including TiO 2 nanoparticles, polystyrene beads labelled with fluorescent dyes, and silver nanoparticles. Some of these test materials could then be developed into certified reference materials over time. No clear consensus was reached regarding the classification of nanomaterials into categories to aid environmental studies, except that a chemistry-based classification system was a reasonable starting point, with some modifications. It was suggested, that additional work may be required

  7. Development of saw palmetto (Serenoa repens) fruit and extract standard reference materials.

    Science.gov (United States)

    Schantz, Michele M; Bedner, Mary; Long, Stephen E; Molloy, John L; Murphy, Karen E; Porter, Barbara J; Putzbach, Karsten; Rimmer, Catherine A; Sander, Lane C; Sharpless, Katherine E; Thomas, Jeanice B; Wise, Stephen A; Wood, Laura J; Yen, James H; Yarita, Takashi; NguyenPho, Agnes; Sorenson, Wendy R; Betz, Joseph M

    2008-10-01

    As part of a collaboration with the National Institutes of Health's Office of Dietary Supplements and the Food and Drug Administration's Center for Drug Evaluation and Research, the National Institute of Standards and Technology has developed two standard reference materials (SRMs) representing different forms of saw palmetto (Serenoa repens), SRM 3250 Serenoa repens fruit and SRM 3251 Serenoa repens extract. Both of these SRMs have been characterized for their fatty acid and phytosterol content. The fatty acid concentration values are based on results from gas chromatography with flame ionization detection (GC-FID) and mass spectrometry (GC/MS) analysis while the sterol concentration values are based on results from GC-FID and liquid chromatography with mass spectrometry analysis. In addition, SRM 3250 has been characterized for lead content, and SRM 3251 has been characterized for the content of beta-carotene and tocopherols. SRM 3250 (fruit) has certified concentration values for three phytosterols, 14 fatty acids as triglycerides, and lead along with reference concentration values for four fatty acids as triglycerides and 16 free fatty acids. SRM 3251 (extract) has certified concentration values for three phytosterols, 17 fatty acids as triglycerides, beta-carotene, and gamma-tocopherol along with reference concentration values for three fatty acids as triglycerides, 17 fatty acids as free fatty acids, beta-carotene isomers, and delta-tocopherol and information values for two phytosterols. These SRMs will complement other reference materials currently available with concentrations for similar analytes and are part of a series of SRMs being developed for dietary supplements.

  8. Determination of Natural Levels of Radionuclides in Proposed Mushroom Reference Material (A Proficiency Test Exercise)

    International Nuclear Information System (INIS)

    Waheed, S.; Rahman, A.; Siddique, N.; Ahmad, S.; Zaidi, J.H.

    2006-08-01

    A proficiency test (PT) was organized within the framework of international Atomic Energy Agency (IAEA) project INT/1/054, entitled 'Preparation' of Reference Materials and Organization of Proficiency Test Rounds'. This exercise served to estimate the proficiency of the analytical laboratories from participating countries. This report presents the results of the proficiency test exercise on the proposed Mushroom Reference Material for the determination of natural levels of radionuclides. Laboratories from 6 different countries submitted data on the following three radionuclides: /sup 134/Cs, /sup 137/Cs, /sup 40/K. Results for /sup 134/Cs, 137/sup 137/Cs, and /sup 40/K in the mushroom reference material were reported by three or more participating laboratories and could be subjected to statistical evaluation. The original data of these raionuclides was subjected to a computer program 'Histo Vession 2.1' provided by IAEA. The four outlier tests i.e. Dixon, Grubbs, Skewness and Kurtosis were applied to the data sets. All values for these three radionuclides were accepted by the software. Consensus (overall) mean value, absolute standard deviation, relative standard deviation, standard error, median and range of values for these three radionuclides have been are obtained (at significance level 0.05). the consensus mean values and confidence intervals are given./sup 134/Cs: 4.4 Bq/kg (3.4-5.3 Bq/kg) /sup 137/Cs: 2899 Bq/kg (2740-3058 Bq/kg) /sup 40/K: 1136 Bq/kg (1046-1226 Bq/kg). (author)

  9. Value determination of ZrO2 in-house reference material (RM) candidate

    International Nuclear Information System (INIS)

    Susanna Tuning Sunanti; Samin; Supriyanto C

    2013-01-01

    The value determination of zirconium oxide in-house reference materials (RM) candidate has been done by referring to ISO:35-2006 standard. The raw material of RM was 4 kg of ZrO 2 , Merck, that was dried at 90°C for 2×6 hours in a closed room. The samples were crushed with stainless steel (SS) pestle to pass ≤ 200 mesh sieve, homogenized in a homogenizer for 3×6 hours to obtain the powdered, dried and homogenous samples. The gravimetric method was performed to test the moisture content, while XRF and AAS methods were used to test the homogeneity and stability of samples candidates. Reference material (RM) candidates of ZrO 2 powder were put into polyethylene bottles, each weighing 100 g. Samples were distributed to 10 testing laboratories that have been accredited for testing the composition of the oxide contents and loss of ignition (LOI) using variety of analytical methods that have been validated such as AAS, XRF, NAA, and UV-Vis. The testing results of oxide content and loss of ignition parameters from various laboratories were analyzed using statistical methods. The testing data of oxide concentration in zirconium oxide RM candidates obtained from various laboratories were ZrO 2 : 97.7334 ± 0.0016%, HfO 2 : 1.7329 ± 0.0024%, SiO 2 : 30.1224 ± 0.0053%, Al 2 O 3 : 0.0245 ± 0.0015%, TiO 2 : 0.0153 ± 0.0006%, Fe 2 O 3 : 0.0068 ± 0.0005%, CdO: 3.1798 ± 0.00006 ppm, and the LOI results was = 0.0217 ± 0.00022%. (author)

  10. Preparation and certification of Re-Os dating reference materials: Molybdenites HLP and JDC

    Science.gov (United States)

    Du, A.; Wu, S.; Sun, D.; Wang, Shaoming; Qu, W.; Markey, R.; Stain, H.; Morgan, J.; Malinovskiy, D.

    2004-01-01

    Two Re-Os dating reference material molybdenites were prepared. Molybdenite JDC and molybdenite HLP are from a carbonate vein-type molybdenum-(lead)- uranium deposit in the Jinduicheng-Huanglongpu area of Shaanxi province, China. The samples proved to be homogeneous, based on the coefficient of variation of analytical results and an analysis of variance test. The sampling weight was 0.1 g for JDC and 0.025 g for HLP. An isotope dilution method was used for the determination of Re and Os. Sample decomposition and preconcentration of Re and Os prior to measurement were accomplished using a variety of methods: acid digestion, alkali fusion, ion exchange and solvent extraction. Negative thermal ionisation mass spectrometry and inductively coupled plasma-mass spectrometry were used for the determination of Re and 187Os concentration and isotope ratios. The certified values include the contents of Re and Os and the model ages. For HLP, the Re content was 283.8 ?? 6.2 ??g g-1, 187Os was 659 ?? 14 ng g-1 and the Re-Os model age was 221.4 ?? 5.6 Ma. For JDC, the Re content was 17.39 ?? 0.32 ng g-1, 187Os was 25.46 ?? 0.60 ng g-1 and the Re-Os model age was 139.6 ?? 3.8 Ma. Uncertainties for both certified reference materials are stated at the 95% level of confidence. Three laboratories (from three countries: P.R. China, USA, Sweden) joined in the certification programme. These certified reference materials are primarily useful for Re-Os dating of molybdenite, sulfides, black shale, etc.

  11. Spiked environmental matrix for use as a reference material for gamma-ray spectrometry: Production and homogeneity test

    International Nuclear Information System (INIS)

    Sobiech-Matura, K.; Máté, B.; Altzitzoglou, T.

    2016-01-01

    The application of a spiking method for reference material production and its utilisation for a food matrix is presented. The raw rice powder was tested by means of γ-ray spectrometry and spiked with a "1"3"7Cs solution. The spiked material was mixed and tested for homogeneity. The future use of the rice powder reference material after the entire characterisation cycle will be for γ-ray spectrometry method validation. - Highlights: • Spiking blank substance with a traceable radioactive solution • Spiked reference material for γ-ray emitting radionuclides in food matrix • Results of the homogeneity tests are presented

  12. Characterisation of candidate reference materials by PIXE analysis and nuclear microprobe PIXE imaging

    International Nuclear Information System (INIS)

    Jaksic, M.; Pastuovic, Z.; Bogdanovic, I.; Tadic, T.

    2002-01-01

    In order to test whether some candidate reference materials show homogeneity that can satisfy quality control of the PIXE technique, six bottles of each of the two Candidate RM's - Lichen (IAEA 338) and Algae (IAEA 413) were tested. Four different tests were performed. First, two pellets from each bottle were prepared and analysed using broad beam (φ = 5 mm) PIXE. Second and third was analysis of homogeneity using scanning focussed beam at the nuclear microprobe. Scans of 50x50 μm 2 and 240x260 μm 2 were performed. Finally, individual grains with composition differing from the rest of the sample, were analysed using PIXE and RBS. (author)

  13. Determination of molybdenum in plant reference material by thermal-ionization isotope-dilution mass spectrometry

    International Nuclear Information System (INIS)

    Saumer, M.; Gantner, E.; Reinhardt, J.; Ache, H.J.

    1992-01-01

    An analytical method is described for the determination of the concentration and the isotopic composition of molybdenum in plant samples using thermal ionization mass spectrometry. After microwave acid digestion and liquid-liquid extractive separation with Amberlite LA-2, the molybdenum isotopes are measured as MoO 3 - -ions in a quadrupole mass spectrometer. In all cases, the relative standard deviation of the measurements of both natural and spike molybdenum was better than 3% for all ratios measured. The concentration of molybdenum found in three different plant reference materials agreed well with the certified values. (orig.)

  14. Certified reference materials of agricultural products and foods bearing radioactivity from the Fukushima nuclear accident

    International Nuclear Information System (INIS)

    Minai, Y.; Miura, T.; Yonezawa, C.; Iwamoto, H.; Shibukawa, M.; Takagai, Y.; Furukawa, M.; Arakawa, F.; Okada, Y.; Kakita, K.

    2016-01-01

    Certified reference materials (CRMs) for food analysis were developed in an inter-laboratory experiment for validation of measurement of radiocesium in foodstuffs. Since 2012, five series of CRMs were developed, including for brown rice grain, soybean powder, beef flake, shiitake mushroom powder and marine fish (meat and bone parts). This paper discusses the strategy of development, including choice of CRMs developed and the preparation and certification procedures applied for CRM development. In particular, some detailed data are presented for the most popular CRMs developed: brown rice grain, soybean powder and beef flake. (author)

  15. A certified reference material for radionuclides in the water sample from Irish Sea (IAEA-443)

    DEFF Research Database (Denmark)

    Pham, M.K.; Betti, M.; Povinec, P.P.

    2011-01-01

    A new certified reference material (CRM) for radionuclides in sea water from the Irish sea (IAEA-443) is described and the results of the certification process are presented. Ten radionuclides (3H, 40K, 90Sr, 137Cs, 234U, 235U, 238U, 238Pu, 239+240Pu and 241Am) have been certified, and information...... values on massic activities with 95% confidence intervals are given for four radionuclides (230Th, 232Th, 239Pu and 240Pu). Results for less frequently reported radionuclides (99Tc, 228Th, 237Np and 241Pu) are also reported. The CRM can be used for quality assurance/quality control of the analysis...

  16. Platinum stable isotope analysis of geological standard reference materials by double-spike MC-ICPMS

    DEFF Research Database (Denmark)

    Creech, John Benjamin; Baker, J. A.; Handler, M. R.

    2014-01-01

    . Double-spiking of samples was carried out prior to digestion and chemical separation to correct for any mass-dependent fractionation that may occur due to incomplete recovery of Pt. Samples were digested using a NiS fire assay method, which pre-concentrates Pt into a metallic bead that is readily...... metal standard solution doped with a range of synthetic matrices and results in Pt yields of ≥90% with purity of ≥95%. Using this chemical separation technique, we have separated Pt from 11 international geological standard reference materials comprising of PGE ores, mantle rocks, igneous rocks and one...

  17. Determination of silicon in biological and botanical reference materials by epithermal INAA and Compton suppression

    International Nuclear Information System (INIS)

    Landsberger, S.; Peshev, S.; Becker, D.A.

    1994-01-01

    Silicon determination in sixteen botanical and biological standard reference materials is described using the 29 Si(n, p) 29 Al reaction through instrumental epithermal neutron activation analysis and Compton suppression gamma-ray spectroscopy. By simultaneous utilization of both cadmium and boron epithermal filters along with anticoincidence gamma-counting, detection limits as low as 12 ppm were obtained for certain matrices, much lower than previously reported values for this type of analysis. The method is applicable to many botanical and biological matrices and is attractive with its interference free, purely instrumental nature, compared with methods using the 28 Si(n, p) 28 Al reaction or chemical separation techniques. ((orig.))

  18. Electron microscopy of fine-grained extraterrestrial materials

    International Nuclear Information System (INIS)

    Mackinnon, I.D.R.; McKay, D.S.; Isaacs, A.M.; Nace, G.

    1982-01-01

    Electron micrographs are shown of (a) Mighei C2 carbonaceous chondrite (variety of matrix phases present; micro-diffraction patterns of a region showing small, discrete intergrowths of planar serpentine and an ordered mixed-layer material; figures showing examples of textures which may be interpreted in terms of alteration processes, and inclusions); and (b) a typical cosmic dust particle collected by high-flying aircraft in the Earth's stratosphere. The composition and morphology of the samples are discussed and their significance. (U.K.)

  19. Highlighting material structure with transmission electron diffraction correlation coefficient maps

    International Nuclear Information System (INIS)

    Kiss, Ákos K.; Rauch, Edgar F.; Lábár, János L.

    2016-01-01

    Correlation coefficient maps are constructed by computing the differences between neighboring diffraction patterns collected in a transmission electron microscope in scanning mode. The maps are shown to highlight material structural features like grain boundaries, second phase particles or dislocations. The inclination of the inner crystal interfaces are directly deduced from the resulting contrast. - Highlights: • We propose a novel technique to image the structure of polycrystalline TEM-samples. • Correlation coefficients maps highlights the evolution of the diffracting signal. • 3D views of grain boundaries are provided for nano-particles or polycrystals.

  20. Fundamental studies to develop certified reference material to calibrate spectrophotometer in the ultraviolet region

    International Nuclear Information System (INIS)

    Da Conceição, F C; Borges, P P; Gomes, J F S

    2016-01-01

    Spectrophotometry is the technique used in a great number of laboratories around the world. Quantitative determination of a high number of inorganic, organic and biological species can be made by spectrophotometry using calibrated spectrophotometers. International standards require the use of optical filters to perform the calibration of spectrophotometers. One of the recommended materials is the crystalline potassium dichromate (K_2Cr_2O_7), which is used to prepare solutions in specific concentrations for calibration or verification of spectrophotometers in the ultraviolet (UV) spectral regions. This paper presents the results concerning the fundamental studies for developing a certified reference material (CRM) of crystalline potassium dichromate to be used as standard of spectrophotometers in order to contribute to reliable quantitative analyses. (paper)