WorldWideScience

Sample records for reduce radiological impacts

  1. Radiological impact of the Argentine Nuclear Programme

    International Nuclear Information System (INIS)

    Gonzalez, A.J.

    1983-01-01

    An assessment is made of the radiological impact resulting from the activities carried out so far under the Argentine Nuclear Programme, together with a prediction of the impact which could result from the future activities planned under that Programme. The average individual risks and the radiological detriment due to the various activities are determined in terms of the average individual effective dose equivalents and the collective effective dose equivalent commitments. The assessments cover exposures of occupationally exposed workers and the public. The data obtained indicate that both the risks and the resultant detriment are reasonably comparable with those derived from other similar programmes. Moreover, they clearly indicate that the radiological impact of the Programme is tending to decrease with time so that it can be assumed that the radiological impact per unit of practice will be even lower in future. (author)

  2. An assessment of the radiological impact of uranium mining in northern Saskatchewan

    International Nuclear Information System (INIS)

    1986-06-01

    This report presents the findings of a study which investigated the regional radiological impact of uranium mining in northern Saskatchewan. The study was performed by IEC Beak Consultants Ltd. under a contract awarded by Environment Canada in partnership with the Atomic Energy Control Board. This preliminary assessment suggests there is a negligible combined regional radiological impact from simultaneous operation of the three operating mines investigated as part of the present study. The mines are spaced too far apart for any superposition of emissions to be significantly greater than a small fraction of background levels. The most exposed individual not directly associated with any of the mining operations is estimated to receive a total radiation dose equal to about 3% of the dose due to natural background radiations. This increment is equivalent to the increment in natural background that would be received by an individual moving from Vancouver to Wollaston Post, before mining began in the area, as a result of reduced atmospheric shielding from cosmic radiation. Radiological impacts on biota are estimated to have insignficant effects on natural populations in all cases. However, since the study only investigates the effects of operational releases of radionuclides, the results do not imply that uranium mining developments will or will not have significant long-term radiological impact on northern Saskatchewan. Radiological impact assessments described in this report are estimates only. There are some uncertainties in the available data and modelling methodology. The radiological impact of abandoned tailings areas was not included in this study

  3. Radiological impacts of uranium recovery in the phosphate industry

    International Nuclear Information System (INIS)

    Ryan, M.T.

    1981-01-01

    This article characterizes the occupational and public radiological health impacts associated with phosphate mining and milling. These impacts are related to the phosphate industry's uranium production potential and are compared with those associated with conventional uranium mining and milling. The radiological impacts resulting from occupational and nonoccupational exposures are assessed. Occupational exposures in phosphate facilities are compared to background exposures and radiological population dose assessments, which characterize important radionuclides and exposure pathways. The following conclusions were reached: (1) public consequences of phosphate mining will occur whether or not uranium is recovered as a by-product, (2) radiological consequences of phosphate mining may be comparable to those associated with uranium mining and milling per unit uranium production, (3) radiological impacts via surface waterways and crops fertilized with uranium-bearing phosphates are of minor consequence, and (4) major radiological public health problems associated with phosphate mining are related to radon and radon progeny exposures in structures built on reclaimed lands or with phosphate mining residues, although the magnitudes of these impacts are difficult to evaluate with current data

  4. A report on CERN’s radiological impact

    CERN Multimedia

    2007-01-01

    The Swiss and French authorities have just published a report showing that CERN’s radiological impact is negligible. The CERN Safety Commission’s Environment Team inspects the river Allondon. Since its foundation more than 50 years ago, questions about the Laboratory’s hypothetical radiological impact have been asked repeatedly by the public. These questions are partly due to the name CERN which, for historical reasons, contains the word nuclear. On 16 October, the Swiss and French authorities published a report that takes stock of CERN’s true radiological impact, providing a detailed and documented answer for all those who wonder about the risks of radioactivity. In their report, the Swiss Office fédéral de la santé publique (OFSP) and the French Institut de radioprotection et de sûreté nucléaire (IRSN), the two bodies responsible for monitoring radiological risks in CERN’s Host States, concluded that CERN’s impac...

  5. Applying Systems Engineering Reduces Radiology Transport Cycle Times in the Emergency Department

    Science.gov (United States)

    White, Benjamin A.; Yun, Brian J.; Lev, Michael H.; Raja, Ali S.

    2017-01-01

    Introduction Emergency department (ED) crowding is widespread, and can result in care delays, medical errors, increased costs, and decreased patient satisfaction. Simultaneously, while capacity constraints on EDs are worsening, contributing factors such as patient volume and inpatient bed capacity are often outside the influence of ED administrators. Therefore, systems engineering approaches that improve throughput and reduce waste may hold the most readily available gains. Decreasing radiology turnaround times improves ED patient throughput and decreases patient waiting time. We sought to investigate the impact of systems engineering science targeting ED radiology transport delays and determine the most effective techniques. Methods This prospective, before-and-after analysis of radiology process flow improvements in an academic hospital ED was exempt from institutional review board review as a quality improvement initiative. We hypothesized that reorganization of radiology transport would improve radiology cycle time and reduce waste. The intervention included systems engineering science-based reorganization of ED radiology transport processes, largely using Lean methodologies, and adding no resources. The primary outcome was average transport time between study order and complete time. All patients presenting between 8/2013–3/2016 and requiring plain film imaging were included. We analyzed electronic medical record data using Microsoft Excel and SAS version 9.4, and we used a two-sample t-test to compare data from the pre- and post-intervention periods. Results Following the intervention, average transport time decreased significantly and sustainably. Average radiology transport time was 28.7 ± 4.2 minutes during the three months pre-intervention. It was reduced by 15% in the first three months (4.4 minutes [95% confidence interval [CI] 1.5–7.3]; to 24.3 ± 3.3 min, P=0.021), 19% in the following six months (5.4 minutes, 95% CI [2.7–8.2]; to 23.3 ± 3

  6. Radiological impacts of spent nuclear fuel management options

    International Nuclear Information System (INIS)

    Riotte, H.; Lazo, T.; Mundigl, S.

    2000-01-01

    An important technical study on radiological impacts of spent nuclear fuel management options, recently completed by the NEA, is intended to facilitate informed international discussions on the nuclear fuel cycle. The study compares the radiological impacts on the public and on nuclear workers resulting from two approaches to handling spent fuel from nuclear power plants: - the reprocessing option, that includes the recycling of spent uranium fuel, the reuse of the separated plutonium in MOX fuel, and the direct disposal of spent MOX fuel; and the once-through option, with no reprocessing of spent fuel, and its direct disposal. Based on the detailed research of a group of 18 internationally recognised experts, under NEA sponsorship, the report concludes that: The radiological impacts of both the reprocessing and the non-reprocessing fuel cycles studied are small, well below any regulatory dose limits for the public and for workers, and insignificantly low as compared with exposures caused by natural radiation. The difference in the radiological impacts of the two fuel cycles studied does not provide a compelling argument in favour of one option or the other. The study also points out that other factors, such as resource utilisation efficiency, energy security, and social and economic considerations would tend to carry more weight than radiological impacts in decision-making processes. (authors)

  7. Radiological environmental impacts from transportation of nuclear materials

    International Nuclear Information System (INIS)

    Shuai Zhengqing

    1994-01-01

    The author describes radiological impacts from transportation of nuclear materials. RADTRAN 4.0 supplied by IAEA was adopted to evaluate radiological consequence of incident-free transportation as well as the radiological risks from vehicular accidents occurring during transportation. The results of calculation show that the collective effective dose equivalent of incident-free transportation to the public and transportation workers is 7.94 x 10 -4 man·Sv. The calculated data suggest that the environmental impacts under normal and assumed accidental conditions are acceptable

  8. Radiological impacts from nuclear facilities on non-human species

    International Nuclear Information System (INIS)

    1997-07-01

    This monograph is the Proceedings of a Symposium on Radiological Impacts from Nuclear Facilities on Non-Human Species, held in Ottawa, Canada, December 1 and 2, 1996. The Symposium was held in response to the assessment of radiological impacts from nuclear facilities on non-human biota by Environment Canada and the move by Atomic Energy Control Board to include the radiological impacts in its regulatory regime. The two major goals of the Symposium were to critically evaluate the ecological risk assessment as applied to radionuclides and contribute to the wide consultation sought by the Atomic Energy Control Board on their new environmental initiatives. The series of papers presented at the Symposium discuss issues relevant to the two major objectives of the Symposium

  9. Implementation of a competency check-off in diagnostic fluoroscopy for radiology trainees: impact on reducing radiation for three common fluoroscopic exams in children

    Energy Technology Data Exchange (ETDEWEB)

    Shah, Sweta [University of Missouri-Kansas City SOM, Department of Radiology, Kansas City, MO (United States); Desouches, Stephane L. [University of Missouri-Kansas City SOM, Department of Radiology, Kansas City, MO (United States); St. Luke' s Hospital, Department of Radiology, Kansas City, MO (United States); Lowe, Lisa H.; Kasraie, Nima; Reading, Brenton [University of Missouri-Kansas City SOM, Department of Radiology, Kansas City, MO (United States); Children' s Mercy Hospitals and Clinics, Department of Radiology, Kansas City, MO (United States)

    2014-07-24

    Fluoroscopy is an important tool for diagnosis in the pediatric population, but it carries the risk of radiation exposure. Because radiology resident education and experience in the use of fluoroscopy equipment in children vary, we implemented an intervention to standardize fluoroscopy training. The purpose of this study is to determine the impact of implementing a fluoroscopy competency check-off for radiology resident trainees aimed at decreasing radiation exposure in three common pediatric fluoroscopic studies. A fluoroscopy competency check-off form was developed for radiology resident trainees performing pediatric procedures. Techniques used to limit radiation exposure for common pediatric radiologic studies were reviewed as part of the check-off process. Pediatric radiologists supervised each trainee until they demonstrated competence to independently perform three specified procedures. Radiation dose was recorded for the three procedures, upper GI (UGI), voiding cystourethrogram (VCUG) and oropharyngeal (OPM) exams, over 6 months preceding and 6 months following implementation of the competency check-off. The mean cumulative dose for each procedure was compared before and after implementation of competency check-off using a Kruskal-Wallis test. During the 12-month study period doses from 909 fluoroscopic procedures were recorded. In the 6 months preceding competency check-off implementation, procedures were performed by 24 radiology resident trainees including 171 UGI, 176 VCUG and 171 OPM exams. In the 6 months following competency check-off, 23 trainees performed 114 UGI, 145 VCUG and 132 OPM exams. After competency check-off implementation, a statistically significant reduction in average radiation dose was found for all three studies (P < 0.001). Median cumulative doses (mGy) were decreased by 33%, 36% and 13% for UGIs, VCUGs and OPMs, respectively. Implementation of a competency check-off for radiology resident trainees can reduce average radiation

  10. Implementation of a competency check-off in diagnostic fluoroscopy for radiology trainees: impact on reducing radiation for three common fluoroscopic exams in children

    International Nuclear Information System (INIS)

    Shah, Sweta; Desouches, Stephane L.; Lowe, Lisa H.; Kasraie, Nima; Reading, Brenton

    2015-01-01

    Fluoroscopy is an important tool for diagnosis in the pediatric population, but it carries the risk of radiation exposure. Because radiology resident education and experience in the use of fluoroscopy equipment in children vary, we implemented an intervention to standardize fluoroscopy training. The purpose of this study is to determine the impact of implementing a fluoroscopy competency check-off for radiology resident trainees aimed at decreasing radiation exposure in three common pediatric fluoroscopic studies. A fluoroscopy competency check-off form was developed for radiology resident trainees performing pediatric procedures. Techniques used to limit radiation exposure for common pediatric radiologic studies were reviewed as part of the check-off process. Pediatric radiologists supervised each trainee until they demonstrated competence to independently perform three specified procedures. Radiation dose was recorded for the three procedures, upper GI (UGI), voiding cystourethrogram (VCUG) and oropharyngeal (OPM) exams, over 6 months preceding and 6 months following implementation of the competency check-off. The mean cumulative dose for each procedure was compared before and after implementation of competency check-off using a Kruskal-Wallis test. During the 12-month study period doses from 909 fluoroscopic procedures were recorded. In the 6 months preceding competency check-off implementation, procedures were performed by 24 radiology resident trainees including 171 UGI, 176 VCUG and 171 OPM exams. In the 6 months following competency check-off, 23 trainees performed 114 UGI, 145 VCUG and 132 OPM exams. After competency check-off implementation, a statistically significant reduction in average radiation dose was found for all three studies (P < 0.001). Median cumulative doses (mGy) were decreased by 33%, 36% and 13% for UGIs, VCUGs and OPMs, respectively. Implementation of a competency check-off for radiology resident trainees can reduce average radiation

  11. Radiological impact assessment in Bagjata uranium deposit: a case study

    International Nuclear Information System (INIS)

    Sarangi, A.K.; Bhowmik, S.C.; Jha, V.N.

    2007-01-01

    The uranium ore mining facility, in addition to the desirable product, produces wastes in the form of environmental releases or effluents to air, water and soil. The toxicological and other (non-radiological) effects are generally addressed in EIA/EMP studies as per MOEF guidelines. Since the uranium ore is radioactive, it is desirable to conduct a study on radiological effects considering the impacts of radiological releases to the environment. Before undertaking the commercial mining operations at Bagjata uranium deposit in the Singhbhum east district of Jharkhand, pre-operational radiological base line data were generated and a separate study on radiological impact on various environmental matrices was conducted in line with the International Atomic Energy Agency's laid out guidelines. The paper describes the philosophy of such studies and the findings that helped in formulating a separate environmental management plan. (author)

  12. Radiological Impacts Assessment during Normal Decommissioning Operation for EU-APR

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Do Hyun; Lee, Keun Sung [KHNP CRI, Daejeon (Korea, Republic of); Lee, ChongHui [KEPCO Engineering and Construction, Gimcheon (Korea, Republic of)

    2016-10-15

    In this paper, radiological impacts on human beings during normal execution of the decommissioning operations from the current standard design of EU-APR which has been modified and improved from its original design of APR1400 to comply with EUR, are evaluated. Decommissioning is the final phase in the life cycle of a nuclear installation, covering all activities from shutdown and removal of fissile material to environmental restoration of the site. According to article 5.4 specified in chapter 2.20 of European Utility Requirements (EUR), all relevant radiological impacts on human being should be considered during the environmental assessment of decommissioning, including external exposure from direct radiation of plant and other radiation sources, and internal exposure due to inhalation and ingestion. In this paper, radiological impacts on human beings during normal circumstances of the decommissioning operation were evaluated from the current standard design of EU-APR based on the simple transport model and practical generic methodology for assessing the radiological impact provided by IAEA. The results of dose assessment fulfilled the dose limit for all scenarios.

  13. Radiological study of bronchial mucoid impaction

    International Nuclear Information System (INIS)

    Yu Xiaoyi; Yan Hongzhen; Wang Tongde; Gan Chunlan; Liu Wei; Wang Linhui

    1999-01-01

    Objective: To evaluate the radiological findings of bronchial mucoid impaction in 28 patients in order to improve diagnostic efficacy. Methods: Standard posteroanterior high voltage radiographs were performed in all 28 cases. Among them CT scans were taken in 14 cases, while 3 patients underwent HRCT examination at the same time. Twenty-two patients had a history of expectoration of mucous plugs; in one case with pulmonary atelectasis, a mucous plug was picked out through bronchoscopy. The other 5 cases experienced a lung operation, and a tumor and bronchial mucoid impaction were discovered. Results: Radiographs showed most mucoid impaction as thick, branching structures resembling branches of tree; others were in the shapes of spherical, small clubs, and cuttle fish. In one patient, pulmonary atelectasis was the only radiographic finding. Similarly on CT, most bronchial mucoid impaction were likened to tree branches; the rest presented as small clubs and bunches of grape. A prominent feature of bronchial mucoid impaction, either on plain radiograph or on CT, was that its axis pointed to the hilum, completely consistent with the branching and distribution of the bronchi, and accompanied by bronchiectasis. Conclusions: It is an optimal approach to exploit plain radiograph combined with CT to find out bronchial mucoid impaction. An awareness of its clinical and radiological features may improve better understanding and recognition of the disease

  14. Radiological impact of oil/gas industry

    International Nuclear Information System (INIS)

    Botezatu, E.; Grecea, C.

    2006-01-01

    The objective of this study was to assess the radiological impact on the environment and population of the oil/gas industry that is non-nuclear industry but uses and can produce materials, with an enhanced content of naturally occurring radionuclides. The natural radioactivity levels in the oil field environmental media, which could represent a risk for the people living in the areas influenced by this non-nuclear industry, do not indicate an increase in the natural radiation background. From a radiological point of view, the situation does not pose any immediate concern. Some places however need further investigations, with special emphasis on the control of 226 Ra releases to prevent from polluting the environment with this radionuclide. The growing concern amongst the population about the quality of their environment increases the significance of impact assessment of radioactive releases into the environment even if natural radionuclides occur. (N.C.)

  15. Citation Impact of Collaboration in Radiology Research.

    Science.gov (United States)

    Rosenkrantz, Andrew B; Parikh, Ujas; Duszak, Richard

    2018-02-01

    Team science involving multidisciplinary and multi-institutional collaboration is increasingly recognized as a means of strengthening the quality of scientific research. The aim of this study was to assess associations between various forms of collaboration and the citation impact of published radiology research. In 2010, 876 original research articles published in Academic Radiology, the American Journal of Roentgenology, JACR, and Radiology were identified with at least one radiology-affiliated author. All articles were manually reviewed to extract features related to all authors' disciplines and institutions. Citations to these articles through September 2016 were extracted from Thomson Reuters Web of Science. Subsequent journal article citation counts were significantly higher (P < .05) for original research articles with at least seven versus six or fewer authors (26.2 ± 30.8 versus 20.3 ± 23.1, respectively), with authors from multiple countries versus from a single country (32.3 ± 39.2 versus 22.0 ± 25.0, respectively), with rather than without a nonuniversity collaborator (28.7 ± 38.6 versus 22.4 ± 24.9, respectively), and with rather than without a nonclinical collaborator (26.5 ± 33.1 versus 21.9 ± 24.4, respectively). On multivariate regression analysis, the strongest independent predictors of the number of citations were authors from multiple countries (β = 9.14, P = .002), a nonuniversity collaborator (β = 4.80, P = .082), and at least seven authors (β = 4.11, P = .038). With respect to subsequent journal article citations, various forms of collaboration are associated with greater scholarly impact of published radiology research. To enhance the relevance of their research, radiology investigators are encouraged to pursue collaboration across traditional disciplinary, institutional, and geographic boundaries. Copyright © 2017 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  16. Relativity Screens for Misvalued Medical Services: Impact on Noninvasive Diagnostic Radiology.

    Science.gov (United States)

    Rosenkrantz, Andrew B; Silva, Ezequiel; Hawkins, C Matthew

    2017-11-01

    In 2006, the AMA/Specialty Society Relative Value Scale Update Committee (RUC) introduced ongoing relativity screens to identify potentially misvalued medical services for payment adjustments. We assess the impact of these screens upon the valuation of noninvasive diagnostic radiology services. Data regarding relativity screens and relative value unit (RVU) changes were obtained from the 2016 AMA Relativity Assessment Status Report. All global codes in the 2016 Medicare Physician Fee Schedule with associated work RVUs were classified as noninvasive diagnostic radiology services versus remaining services. The frequency of having ever undergone a screen was compared between the two groups. Screened radiology codes were further evaluated regarding the RVU impact of subsequent revaluation. Of noninvasive diagnostic radiology codes, 46.0% (201 of 437) were screened versus 22.2% (1,460 of 6,575) of remaining codes (P < .001). Most common screens for which radiology codes were identified as potentially misvalued were (1) high expenditures (27.5%) and (2) high utilization (25.6%). The modality and body region most likely to be identified in a screen were CT (82.1%) and breast (90.9%), respectively. Among screened radiology codes, work RVUs, practice expense RVUs, and nonfacility total RVUs decreased in 20.3%, 65.9%, and 75.3%, respectively. All screened CT, MRI, brain, and spine codes exhibited decreased total RVUs. Policymakers' ongoing search for potentially misvalued medical services has disproportionately impacted noninvasive diagnostic radiology services, risking the introduction of unintended or artificial shifts in physician practice. Copyright © 2017 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  17. Research progress of non-human species radiological impact and assessment

    International Nuclear Information System (INIS)

    Bai Xiaoping; Zhu Hao; Mao Yawei; Zheng Wei; Du Hongyan

    2014-01-01

    In recent years, with the development of radiological protection conception and the improvement of requirement about non-human species protection, much more attention has been paid gradually to biota radiation impact. Research and development of non-human species protection impact and its assessment at home and abroad are introduced, then RESRAD-BIOTA and ERICA which are comparatively mature codes in the world are compared and analyzed, at last some suggestions about research and assessment work of non-human species radiological impact in the future in China are provided. (authors)

  18. Study and radiological impact assessment produced by activities of different non-nuclear industries. Titanium dioxide industries

    International Nuclear Information System (INIS)

    Garcia-Tenorio, R.; Manjon, G.; Abril, J.M.

    2010-01-01

    After a careful study and evaluation of radiological impact, the conclusion is that these industries do not need to be subject to control, and it is not necessary any corrective action to reduce the exposition and/or to apply any radiation protection measures.

  19. Assessment of the radiological impact of the transport of radioactive materials

    International Nuclear Information System (INIS)

    1986-12-01

    In order to facilitate the assessment of the radiological impact of transport, and to guide the collection of data for future assessments, the IAEA convened a technical committee (The Technical Committee on the Assessment of the Radiological Impact from the Transport of Radioactive Materials; TC-556) in Vienna, Austria on 21-25 October 1985. The Terms of Reference called for this committee ''to collect and assess data on the radiation exposure of workers and the public during the transport of radioactive material, and to develop a summary statement, reflecting current practice and current state of knowledge, on the radiological impact of transport.'' This technical document provides the summary statement developed by TC-556. The statement should be viewed as an interim assessment since it utilized only data then available, or made available, to the committee. This document consists of three Sections: Section I - Background Information to the Summary Statement (prepared by the Secretariat); Section II - The Summary Statement on the Radiological Impact of the Transport of Radioactive Materials (developed by TC-556); and Section III - Recommendations for Future Assessments (a summary of statements and conclusions provided in the TC-556 Chairman's Report)

  20. Assessment of the radiological impact of contaminated discharges

    Energy Technology Data Exchange (ETDEWEB)

    Sweeck, L; Zeevaert, T

    1996-09-18

    A biosphere model has been used to calculate the release of radionuclides from contaminated soils and their dose impact on critical individuals in the environment. Normal evolution and accidental scenarios are considered. The objective of the model is to provide an indication of the radiological risk rather than to predict its future impact.

  1. Comparison of the radiological impacts of thorium and uranium nuclear fuel cycles

    International Nuclear Information System (INIS)

    Meyer, H.R.; Witherspoon, J.P.; McBride, J.P.; Frederick, E.J.

    1982-03-01

    This report compares the radiological impacts of a fuel cycle in which only uranium is recycled, as presented in the Final Generic Environmental Statement on the Use of Recycle Plutonium in Mixed Oxide Fuel in Light Water Cooled Reactors (GESMO), with those of the light-water breeder reactor (LWBR) thorium/uranium fuel cycle in the Final Environmental Statement, Light Water Breeder Reactor Program. The significant offsite radiological impacts from routine operation of the fuel cycles result from the mining and milling of thorium and uranium ores, reprocessing spent fuel, and reactor operations. The major difference between the impacts from the two fuel cycles is the larger dose commitments associated with current uranium mining and milling operations as compared to thorium mining and milling. Estimated dose commitments from the reprocessing of either fuel type are small and show only moderate variations for specific doses. No significant differences in environmental radiological impact are anticipated for reactors using either of the fuel cycles. Radiological impacts associated with routine releases from the operation of either the thorium or uranium fuel cycles can be held to acceptably low levels by existing regulations

  2. Hypothetical influence of non-indexed Spanish journals on the impact factor of radiological journals

    International Nuclear Information System (INIS)

    Miguel-Dasit, Alberto; Aleixandre, Rafael; Valderrama, Juan C.; Marti-Bonmati, Luis; Sanfeliu, Pilar

    2005-01-01

    Objective: The aim of this study was to analyze the hypothetical changes in the 2001 impact factor of 52 radiological journals included in the Science Citation Index-Journal Citation Reports by also counting cites proceeding from 73 Spanish journals on different medical specialties. Also, to estimate the possible impact factor of the official Spanish radiology journal, Radiologia, not included in this database. Materials and methods: A modified 2001 impact factor of 52 radiological journals and Radiologia was obtained by adding the number of cites in 1999 and 2000 from the medical Spanish journals. Data were obtained by consulting the 2001 edition of the Journal Citation Reports in the 'Web of Science' database. Results: The 16,985 bibliographical references were analysed (232 of them to radiological journals). The journal with the largest increase in its 2001 impact factor (from 1.83 to 1.90) was Radiologic Clinics of North America. European Journal of Radiology was the European journal with the highest increase (from 1.084 to 1.110) in the difference between the 2001 modified and original impact factor. The modified 2001 impact factor of the 34 American journals was statistically higher (P = 0.016) than that of the 18 European journals (1.64 versus 0.93). Differences between the 2001 modified and original impact factor were slightly higher in the American journals (no statistically significant difference). The 2001 impact factor of Radiologia was 0.056. Discussion: Differences between the 2001 original and modified impact factor were small, but larger in the American journals. The 2001 impact factor of Radiologia was modest, although similar to other publications included in the Journal Citation Reports

  3. Selection of nuclide decay chains for use in the assessment of the radiological impact of geological repositories for radioactive waste

    International Nuclear Information System (INIS)

    Thorne, M.C.

    1982-12-01

    The criteria for selecting nuclide decay chains for use in the assessment of the radiological impact of geological repositories for radioactive waste are given. The reduced chains recommended for use with SYVAC are described. (author)

  4. A probabilistic approach to Radiological Environmental Impact Assessment

    International Nuclear Information System (INIS)

    Avila, Rodolfo; Larsson, Carl-Magnus

    2001-01-01

    Since a radiological environmental impact assessment typically relies on limited data and poorly based extrapolation methods, point estimations, as implied by a deterministic approach, do not suffice. To be of practical use for risk management, it is necessary to quantify the uncertainty margins of the estimates as well. In this paper we discuss how to work out a probabilistic approach for dealing with uncertainties in assessments of the radiological risks to non-human biota of a radioactive contamination. Possible strategies for deriving the relevant probability distribution functions from available empirical data and theoretical knowledge are outlined

  5. Discussion on the method of environmental radiological impact assessment for the highway construction project

    International Nuclear Information System (INIS)

    Qiu Guohua

    2008-01-01

    Based on the characteristics and environmental radiological impact of the highway construction project, the basic procedure of environmental radiological impact assessment for the highway construction project is put forward, including analysis and determination of contamination sources, selection of evaluation factors, determination of assessment range and dose limit, environmental investigation, environmental impact prediction and assessment. The working method of each procedure is analyzed. (authors)

  6. Methodology for assessing the radiological impact on environment

    International Nuclear Information System (INIS)

    Zhang Yongxing

    1988-01-01

    During the 1940s, the early stages of nuclear programmes, the assessment of the radionuclides released to the environment was first initiated for the large nuclear facilities, with emphasis placed on environmental monitoring. The radiological assessment is a quantitative process of estimating the impact on human, resulting from the releases of the radionuclides to the environment. It is a multidisciplinary subject including identification of source terms, environmental transport and dispersion, health effect evaluation and so on. This paper briefly, but comprehensively, describes the methodology for the assessment of the environmental radiological consequence, and discusses the trend of various research fields related to the subject

  7. Radiological impact assessment of arc welding supplies rutile

    International Nuclear Information System (INIS)

    Rozas Guinea, S.; Herranz Soler, M.; Perez Marin, C.; Idoeta Hermandorena, R.; Alegria gutierrez, N.; Nunez-Lagos Rogla, R.; Legarda Ibanez, F.

    2013-01-01

    Consumables for welding containing rutile, the coating of the electrode or the filling of tubular thread, are the most widely used and also the most radioactive since the rutile is a mineral containing traces of natural radionuclides, and is therefore considered Normal Occurring Radioactive Material (NORM). As these electrodes and wire are consumed, small particles, aerosols and gases are emitted to the atmosphere of work, and may be inhaled by the welder. Therefore, and also according to the current regulatory framework and work carried out previously by the author on the radiological impact of the process of manufacture and storage of coated rutile electrodes, the objectives are: 1Calcular the internal dose for inhalation during two types of welding, one with electrodes coated and the other with thread. 2 calculate the external dose due to the deposition of particles in the work environment, slag and the immersion of the soldering iron in the cloud of smoke. 3 to assess the radiological impact. (Author)

  8. Application of the ICRP approach for radiological protection of the marine environment in generic impact assessments

    Energy Technology Data Exchange (ETDEWEB)

    Kliaus, Viktoryia [Republican Scientific-Practical Centre of Hygiene, Laboratory of Radiation Safety, Akademicheskaya str. 8, 220012, Minsk (Belarus); Telleria, Diego M. [IAEA-Assessment and Management of Environmental Releases Unit, Wagramer Strasse 5 - PO Box 100, A-1400, Vienna (Austria); Cabianca, Tiberio [Centre for Radiation, Chemical and Environmental Hazards, PHE, Chilton, Didcot, Oxfordshire OX11 0RQ (United Kingdom)

    2014-07-01

    This paper presents a way to use the ICRP approach for protection of the environment in generic assessments of the radiological impact of radioactive releases to the marine environment. Generic assessments of radiological impact to the environment are needed in certain circumstances, for example, when input data are limited or when the likely radiological consequences are expected to be not significant. Under these circumstances the effort in performing the assessment must be commensurate with the potential radiological consequences. The generic assessment described in this paper is a simple tool which provides reasonable and cautious results and is applicable to multiple exposure scenarios associated with the assessment of the radiological impact of releases to the marine the environment. This generic assessment can be also used to provide preliminary results which, when compared to radiological criteria, may determine the need of further specific assessments. The ICRP based its approach to protect the environment in the definition of a set of reference animals and plants and the use of related radiological criteria, in the form of derived consideration reference levels. The paper discusses selection and exposure conditions of the reference animals and plants, methods to estimate their doses and the use of the radiological criteria, for the purpose of a generic assessment. The IAEA is elaborating applications of these generic impact assessments presented in the paper to be included in international guidance under development. (authors)

  9. Below Regulatory Conern Owners Group: Radiologic impact of accidents and unexpected events from disposal of BRC waste

    International Nuclear Information System (INIS)

    Waite, D.A.; Dolan, M.M.; Rish, W.R.; Rossi, A.J.; McCourt, J.E.

    1989-07-01

    This report determines the radiological impact of accidents and unexpected events in the disposal of Below Regulatory Concern (BRC) waste. The accident analysis considers the transportation, incineration, and disposal of BRC waste as municipal solid waste. The potential greatest radiological impact for each type of accident is identified through the use of event trees. These accident events are described in terms of the generic waste property(ies) (e.g., flammability, dispersibility, leachability, and solubility) that cause the greatest radiological impact. 7 refs., 32 figs., 12 tabs

  10. Radiological impact assessment on non-human species from the radioactive waste disposal

    International Nuclear Information System (INIS)

    Gil Castillo, Reinaldo; Peralta Vital, Jose L.; Leiva Bombuse, Dennys

    2008-01-01

    The paper shows the use of a methodology in order to carry out the radiological impact assessment in non-human species (animals and plants) from a planned radioactive waste disposal facility. The application of modelling tools to simulate the behaviour (release and transport) of the radionuclides through the engineered barriers and the geosphere, and its final access to the soil and a river are described too. To evaluate the compliance with the adopted biota dose limits, were used the calculated maximum radionuclide concentrations for different environmental compartments (water, soil and sediment). Preliminary, the results showed that the Radiological Biota impacts are acceptable according to the adopted criteria (Radionuclides concentrations below the Biota Concentration Guides). The results showed that according theirs impact the more important radionuclides were: 241 Am/ 226 Ra/ 137 Cs/ 60 Co. The Riparian animals were the more exposed Biota organism. The results support the decision making process since could be identified the relevant radiological impact in the environment (plants and animals) near to a disposal facility (real or planned). Also the paper identified methodological tools useful to evaluate the site acceptance, for the early stages of disposal facilities (site selection process, licensing, etc), in absence of real data of radionuclides concentrations in the environment. (author)

  11. Alternative Metrics ("Altmetrics") for Assessing Article Impact in Popular General Radiology Journals.

    Science.gov (United States)

    Rosenkrantz, Andrew B; Ayoola, Abimbola; Singh, Kush; Duszak, Richard

    2017-07-01

    Emerging alternative metrics leverage social media and other online platforms to provide immediate measures of biomedical articles' reach among diverse public audiences. We aimed to compare traditional citation and alternative impact metrics for articles in popular general radiology journals. All 892 original investigations published in 2013 issues of Academic Radiology, American Journal of Roentgenology, Journal of the American College of Radiology, and Radiology were included. Each article's content was classified as imaging vs nonimaging. Traditional journal citations to articles were obtained from Web of Science. Each article's Altmetric Attention Score (Altmetric), representing weighted mentions across a variety of online platforms, was obtained from Altmetric.com. Statistical assessment included the McNemar test, the Mann-Whitney test, and the Pearson correlation. Mean and median traditional citation counts were 10.7 ± 15.4 and 5 vs 3.3 ± 13.3 and 0 for Altmetric. Among all articles, 96.4% had ≥1 traditional citation vs 41.8% for Altmetric (P nonimaging content (11.5 ± 16.2 vs 6.9 ± 9.8, P nonimaging content (5.1 ± 11.1 vs 2.8 ± 13.7, P = 0.006). Although overall online attention to radiology journal content was low, alternative metrics exhibited unique trends, particularly for nonclinical articles, and may provide a complementary measure of radiology research impact compared to traditional citation counts. Copyright © 2017 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  12. Long term radiological impact of a uranium mine restoration

    International Nuclear Information System (INIS)

    Mora, Veronica; Bordonaba Marisa; Sanchez Guillermo

    2008-01-01

    During the 1990s, many uranium mines were closed as consequence of low prices of this mineral. It was due to a decrease in the demand for uranium and an increase in the overall supply. The resulting was a further complicated implementation of sites restorations. This report deals with one of the relevant aspects of the radiological protection scope: 'the evaluation of the long term radiological impact in the population due to the uranium mine restoration activities' for the uranium mine sited in Saelices el Chico (Salamanca, Spain). These restoration activities have basically consisted of recovering the original site by filling the old open pits with the material stockpiled in the waste dumps. The main problems associated with this material include radon release and particles emission. The strategy used to solve this problem has been covered these structures with a layer with beds of clay material rock, waste material and a cover tree. The pathways considered for the radiological impact have been: 1) Inhalation; 2) Ingestion of contaminated water, milk, vegetables and meat; 3) External exposure from clouds immersion, grounds concentrations and direct gamma radiation. Three computer codes have been used with the object of evaluating the above-mentioned impact. Two of them are well-known NRC (Nuclear Regulatory Commission) codes: RESRAD 6.30 and MILDOS-AREA. We have also applied DOEFLURA, developed in ENUSA [1, 2, 3]. Four scenarios have been studied: Resident Farmer Scenario, Resident scenario, Livestock pasture scenario and Forest scenario, Estimation of radioactive doses for the member of the public in the different scenarios has been calculated with this programme. A period of 3500 years from now has been studied. (author)

  13. Extracorporeal shock wave lithotripsy: Involvement and impact on radiology at a kidney stone center

    International Nuclear Information System (INIS)

    Cochran, S.T.; Barbaric, Z.L.; Mindell, H.; Chaussy, C.D.; Fuchs, G.J.

    1986-01-01

    Of 1,222 extracorporeal shock wave lithotripsy (ECSW) procedures performed on 925 patients (600 males, 325 females), 85% were unilateral and 35% were bilateral treatments. Treated were 446 calyceal, 345 pelvic, 172 uretral, and 108 staghorn calculi. The impact of this new technology to the radiology department was studied. An average of 6.3 KUB studies and 1.2 renal US studies were performed per treatment session. Six percent of patients required post-ESWL excretory urography of CT; 10% required percutaneous nephrostomy. Patients with treated staghorn calculi required the most radiologic procedures (34% performed for partial staghorn calculi, 56% for complete staghorn calculi). By comparison, 3%, 8%, and 11% of radiologic procedures were performed for calyceal, pelvic, and ureteral stones, respectively. The impact of ESWL on the radiology department can be substantial. When staghorn calculi are treated by ESWL, a radiologist skilled in interventional techniques is essential

  14. A regulatory perspective on the radiological impact of NORM industries: the case of the Spanish phosphate industry

    International Nuclear Information System (INIS)

    Garcia-Talavera, M.; Matarranz, J.L.M.; Salas, R.; Ramos, L.

    2011-01-01

    Radioactive and chemical risks coexist in NORM industries although they are usually addressed separately by regulations. The European Union (EU) has developed extensive legislation concerning both matters, which has been diversely reflected in national policies. We consider the case of the Spanish phosphate industry and analyse to which extent regulatory mandates have reduced the historical and ongoing radiological impact on the environment of phosphate facilities. Although no specific radiological constraints on effluent monitoring and release or on waste disposal have yet been imposed on NORM industries in Spain, other environmental regulations have achieved a substantial reduction on the phosphate industry impact. Nevertheless, a more efficient control could be established by eliminating the current conceptual and practical separation of chemical and radioactive risks in NORM industries. We highlight research needs to accomplish so and propose shorter-term measures that require active cooperation among the regulatory bodies involved. - Research highlights: → The radiological impact of the Spanish phosphate industry has substantially decreased as a side result of environmental regulations on chemical pollution.→ A more efficient control of NORM industries could be established by eliminating the current conceptual and practical separation of chemical and radioactive risks.→ Further research is needed on how interactions between radiation and chemicals might affect regulatory limits and on a systematic way to input stakeholder preferences in MCDA.→ On shorter-term, administrative measures that require active cooperation among the regulatory bodies involved can be taken.

  15. Phosphate gypsum wastes in Venice lagoon. Radiological impact

    International Nuclear Information System (INIS)

    Belli, M; Blasi, M; Guogang, J.; Rosamilia, S.; Sansone, U.; Biancotto, R.; Bidoli, P.; Sepulcri, D.

    2000-03-01

    The phosphoric minerals utilized in phosphoric acid production, presents high concentrations of radioactive materials: U238, Th 232, K 40. The phosphogypsum is the waste material obtained in the phosphoric acid production in wet process. This type of production method is employed for many years in Venice lagoon (Porto Marghera chemical plants). In this paper are reported evaluations of radiological impact on aquatic environment of lagoon [it

  16. The disposal of high level radioactive waste and the need for assessing the radiological impact

    International Nuclear Information System (INIS)

    Johansson, G.; Haegg, C.

    1990-01-01

    Different options for the disposal of high level radioactive waste are being considered in several different countries. When assessing the possible future impact of these disposal concepts, very large uncertainties are associated with the predictions. These uncertainties include scenario representation, conceptual and mathematical modelling, parameter evaluation and finally the interpretation of the results. Some of these uncertainties cannot be eliminated regardless of research efforts, e.g. the evolution of the society and the environment. The paper discusses in general terms to what extent uncertainties in the predictions could be reduced and in the light of this discussion the authors present their point of view regarding the fruitfulness of assessing radiological impact in the far future. (orig.)

  17. Radiation monitoring systems and methodologies for radiological impact assessment

    International Nuclear Information System (INIS)

    Chaudhury, Probal

    2016-01-01

    Radioactive sources of various strengths are used in large number of applications in industry, healthcare, agriculture and research. Though all the sources are transported and used under regulatory control, there is always a possibility of some of the sources getting into the hands of committed antisocial non state actors. In addition to this, there is a possible threat of radioactive material being illegally brought into a country. These gives rise to an increase in the global radiological threat and security experts world over are concerned about the possibility of malicious use of radiation in the public domain. Radiation detection systems are installed at various entry and exit ports of some of the countries to detect illicit trafficking of radioactive materials. IAEA has recommended that all States should have a national response plan for nuclear security events to provide for an appropriate and coordinated response. Considering the requirement of radiological emergency preparedness, various radiation monitoring systems and methodologies have been developed. A few aerial radiation monitoring systems developed at Bhabha Atomic Research Centre (BARC) for radiological impact assessment are described here

  18. Sampling on radiological protection training in diagnostic radiology

    International Nuclear Information System (INIS)

    Gaona, E.

    2001-01-01

    Radiological security aspects were evaluated in radiology departments from Mexico City. The study was carried out in two stages, the first one evaluated 40 departments just before the implementation of the new Official Mexican Standards related to Radiological Security and Quality Control in Radiology; in the second stage 33 departments were evaluated 2 years after those standards were implanted, showing a favorable impact of the training programs for the type of answers obtained [es

  19. Evaluation of long term radiological impact on population close to remediated uranium mill tailings storages

    International Nuclear Information System (INIS)

    Kerouanton, David; Delgove, Laure

    2008-01-01

    A methodology is elaborated in order to evaluate the long term radiological impact of remediated uranium mill tailings storage. Different scenarios are chosen and modelled to cover future evolution of the tailings storages. Radiological impact is evaluated for different population such as adults and children living in the immediate vicinity or directly on the storage, road workers or walkers on the storage. Equation and methods are detailed. (author)

  20. The economics of interventional radiology

    International Nuclear Information System (INIS)

    Price, G.W.

    1988-01-01

    At a time when policy makers and regulators are scheming to reduce the costs and utilization of medical services, interventional radiology is poised for growth. Part of this potential for growth is based on wider acceptance of the procedures performed by interventional radiologists. A second factor in the growth potential is the relative value in cost of these procedures compared with alternative therapies. The author presents a discussion of the differences in the relative value of these procedures when performed by physicians of different specialties. This paper reviews the status of the economic climate in the health care delivery system and the role and potential growth of interventional radiology. This includes a review of current data on the utilization of interventional radiology procedures in the Medicare program. This overview includes a discussion of the initiatives of the federal government which directly impact interventional radiology

  1. Global radiological impact of the phosphate fertilizers

    International Nuclear Information System (INIS)

    Morales, Rudnei Karam; Alves, Rex Nazare

    1996-01-01

    About ninety percent of the products obtained in the phosphate industry are directly used in agriculture as fertilizers. The uranium, thorium and radium content in phosphate fertilizers pollute the soil, water and air, creating risks due to associated natural radiation. This work shows the concentration of radionuclides present in various products of the national and American phosphate fertilizers industry, and compared them with worldwide mean values. The radiological impact of the products on the environment is evaluated and suggestions are presented in order to minimize the risks due to radioactivity. (author)

  2. Radiological impact assessment within the IAEA Arctic Assessment Project (IASAP)

    DEFF Research Database (Denmark)

    Scott, E.M.; Gurbutt, P.; Harmes, I.

    1998-01-01

    As part of the International Arctic Seas Assessment Project (IASAP) of IAEA, a working group was created to model the dispersal and transfer of radionuclides released from radioactive waste disposed of in the Kara Sea and bays of Novaya Zemlya and to assess the radiological impact. Existing models...

  3. Research and development in radiological protection

    International Nuclear Information System (INIS)

    Butragueno, J. L.; Villota, C.; Gutierrez, C.; Rodriguez, A.

    2004-01-01

    The objective of Radiological Protection is to guarantee that neither people, be they workers or members of the public, or the environment are exposed to radiological risks considered by society to be unacceptable. Among the various resources available to meet this objective is Research and Development (R and D), which is carried out in three areas: I. Radiological protection of persons: (a) knowledge of the biological effects of radiations, in order to determine the relationship that exists between radiation exposure dose and its effects on health; (b) the development of new personal dosimetry techniques in order to adapt to new situations, instrumental techniques and information management technologies allowing for better assessment of exposure dose; and (c) development of the principle of radiological protection optimisation (ALARA), which has been set up internationally as the fundamental principle on which radiological protection interventions are based. II. Assessment of environmental radiological impact, the objective of which is to assess the nature and magnitude of situations of exposure to ionising radiations as a result of the controlled or uncontrolled release of radioactive material to the environment, and III.Reduction of the radiological impact of radioactive wastes, the objective of which is to develop radioactive material and waste management techniques suitable for each situation, in order to reduce the risks associated with their definitive management or their release to the environment. Briefly described below are the strategic lines of R and D of the CSN, the Electricity Industry, Ciemat and Enresa in the aforementioned areas. (Author)

  4. Study of the Radiological Impact of the Coal Fired Power Plants on the Environment. The As Pontes coal-fired Power Plant

    International Nuclear Information System (INIS)

    Cancio, D.; Robles, B.; Mora, J. C.

    2009-01-01

    As part of the Study carried out to determine the radiological impact of the four main Spanish coal-fired power plants, the Study on the As Pontes Coal-Fired Coal Power Plant was finalized. In the Report containing the study are included every measurement performed, as well as the modelling and evaluations carried out in order to assess the radiological impact. The general conclusion obtained is that under a radiological point of view, the impact of this installation on the public and the environment is very small. Also the radiological impact on the workers of the installation was assessed, obtaining too very small increases over the natural background. (Author) 61 refs.

  5. The differential radiological impact of plutonium recycle in the light-water reactor fuel cycle: effluent discharges during normal operation

    International Nuclear Information System (INIS)

    Bouville, A.; Guetat, P.; Jones, J.A.; Kelly, G.N.; Legrand, J.; White, I.F.

    1980-01-01

    The radiological impact of a light-water reactor fuel cycle utilizing enriched uranium fuel may be altered by the recycle of plutonium. Differences in impact may arise during various operations in the fuel cycle: those which arise from effluents discharged during normal operation of the various installations comprising the fuel cycle are evaluated in this study. The differential radiological impact on the population of the European Communities (EC) of effluents discharged during the recycling of 10 tonnes of fissile plutonium metal is evaluated. The contributions from each stage of the fuel cycle, i.e. fuel fabrication, reactor operation and fuel reprocessing and conversion, are identified. Separate consideration is given to airborne and liquid effluents and account is taken of a wide range of environmental conditions, representative of the EC, in estimating the radiological impact. The recycle of plutonium is estimated to result in a reduction in the radiological impact from effluents of about 30% of that when using enriched uranium fuel

  6. Radiological protection in interventional radiology

    International Nuclear Information System (INIS)

    Padovani, R.

    2001-01-01

    Interventional radiology (IR) reduces the need for many traditional interventions, particularly surgery, so reducing the discomfort and risk for patients compared with traditional systems. IR procedures are frequently performed by non-radiologist physicians, often without the proper radiological equipment and sufficient knowledge of radiation protection. Levels of doses to patients and staff in IR vary enormously. A poor correlation exists between patient and staff dose, and large variations of dose are reported for the same procedure. The occurrence of deterministic effects in patients is another peculiar aspect of IR owing to the potentially high skin doses of some procedures. The paper reviews the use of IR and the radiological protection of patients and staff, and examines the need for new standards for IR equipment and the training of personnel. (author)

  7. Politics, economics, and the law: Impact on and responses by radiology

    International Nuclear Information System (INIS)

    Hillman, B.J.; James, A.E. Jr.

    1987-01-01

    Recent changes in government regulation and third-party reimbursement, and the rapid development of alternative health care delivery systems, are having large impact on the practice of radiology. In the first half of this course we examine the origins of these changes and evaluate the current and future strategies of the major instigators. Initiatives intended to reduce health care costs will be discussed in the context of their effect on radiologists' access to patients and equipment. Topics will include the regulation of expensive imaging technology and such alternative physician payment mechanisms as MD-DRGs, RAPs, relative value scales, and capitation. Government and third-party payors' efforts to instill market mechanisms to reduce physician costs will also be discussed. The second part of the program will focus on potential responses of radiologists to the changing milieu. Using a case method approach, the authors discuss the benefits and dangers associated with such possibilities as exclusive contracts and entrapreneurial ventures, and how such considerations as liability, fiscal, responsibility for technology, and antitrust legislation impinge on radiologists' decisions

  8. Long term radiological impact of thorium extraction

    International Nuclear Information System (INIS)

    Menard, S.; Schapira, J.P.

    1995-01-01

    Thorium extraction produces a certain amount of radioactive wastes. Potential long term radiological impact of these residues has been calculated using the recent ICRP-68 ingestion dose factors in connection with the computing code DECAY, developed at Orsay and described in this work. This code solves the well known Bateman's equations which govern the time dependence of a set of coupled radioactive nuclei. Monazites will be very likely the minerals to be exploited first, in case of an extensive use of thorium as nuclear fuel. Because monazites contain uranium as well, mining residues will contain not only the descendants of 232 Th and a certain proportion of non-extracted thorium (taken here to be 5%), but also this uranium, if left in the wastes for economical reasons. If no uranium would be present at all in the mineral, the potential radiotoxicity would strongly decrease in approximately 60 years, at the pace of the 5.8 years period of 228 Ra, which becomes the longest-lived radionuclide of the 4n radioactive family in the residues. Moreover, there is no risk due to radon exhalation, because of the very short period of 220 Rn. These significant differences between uranium and thorium mining have to be considered in view of some estimated long term real radiological impacts due to uranium residues, which could reach a value of the order of 1 mSv/year, the dose limit recommended for the public by the recent ICRP-60. (authors). 15 refs., 4 figs., 3 tabs., 43 appendices

  9. Investigation of evaluation method for marine radiological impact during an accident

    International Nuclear Information System (INIS)

    2013-01-01

    In 2012, JNES investigated the evaluation method, long-term seawater and marine deposition for release and diffusion to the ocean at the accident, and marine impact assessment code, in Japan and overseas. Also, the foreign regulations for marine radiological impact (direct release to ocean from the facilities and fallout on marine, etc.) were investigated. Furthermore, the index (e.g., intervention level) at emergency control in USA and Europe were investigated. (author)

  10. Investigation of evaluation method for marine radiological impact during an accident

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2013-08-15

    In 2012, JNES investigated the evaluation method, long-term seawater and marine deposition for release and diffusion to the ocean at the accident, and marine impact assessment code, in Japan and overseas. Also, the foreign regulations for marine radiological impact (direct release to ocean from the facilities and fallout on marine, etc.) were investigated. Furthermore, the index (e.g., intervention level) at emergency control in USA and Europe were investigated. (author)

  11. Investigation of evaluation method for marine radiological impact during an accident

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2012-08-15

    In 2012, JNES carried out to investigate the measurement information of radionuclide released to the ocean at Fukushima Daiichi NPP accident, the foreign regulation for marine radiological impact, and the evaluation method for release and diffusion to the ocean at the accident inside and outside Japan. (author)

  12. The radiological impact of radionuclides dispersed on a regional and global scale: Methods for assessment and their application

    International Nuclear Information System (INIS)

    1985-01-01

    The basic features of models, developed to assess the radiological impact of radionuclides that become dispersed on a regional or global scale, have been reviewed. Particular attention has been given to identifying the important processes that need to be modelled in order to make a reliable estimate of the radiological impact, rather than attempting to judge which models are the most appropriate. Judgements on the latter will be sensitive to the particular application; in some cases a very simple approach may be sufficient, whereas in others a more rigorous analysis may be necessary. Two aspects are important in assessing the radiological impact: these are the exposure of critical groups, and the collective dose in the exposed population

  13. The Use of Twitter by Radiology Journals: An Analysis of Twitter Activity and Impact Factor.

    Science.gov (United States)

    Kelly, Brendan S; Redmond, Ciaran E; Nason, Gregory J; Healy, Gerard M; Horgan, Niall A; Heffernan, Eric J

    2016-11-01

    Medical journals use social media as a means to disseminate new research and interact with readers. The microblogging site Twitter is one such platform. The aim of this study was to analyze the recent use of Twitter by the leading radiology journals. The top 50 journals by Impact Factor were included. Twitter profiles associated with these journals, or their corresponding societies, were identified. Whether each journal used other social media platforms was also recorded. Each Twitter profile was analyzed over a one-year period, with data collected via Twitonomy software. Klout scores of social media influence were calculated. Results were analyzed in SPSS using Student's t test, Fisher contingency tables, and Pearson correlations to identify any association between social media interaction and Impact Factors of journals. Fourteen journals (28%) had dedicated Twitter profiles. Of the 36 journals without dedicated Twitter profiles, 25 (50%) were associated with societies that had profiles, leaving 11 (22%) journals without a presence on Twitter. The mean Impact Factor of all journals was 3.1 ± 1.41 (range, 1.7-6.9). Journals with Twitter profiles had higher Impact Factors than those without (mean, 3.37 vs 2.14; P Twitter profiles and those associated with affiliated societies (P = .47). Since joining Twitter, 7 of the 11 journals (64%) experienced increases in Impact Factor. A greater number of Twitter followers was correlated with higher journal Impact Factor (R 2  = 0.581, P = .029). The investigators assessed the prevalence and activity of the leading radiology journals on Twitter. Radiology journals with Twitter profiles have higher Impact Factors than those without profiles, and the number of followers of a journal's Twitter profile is positively associated with Impact Factor. Copyright © 2016 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  14. Radiological impact of high activity wastes disposal in a granitic rock

    International Nuclear Information System (INIS)

    Oliveira, A.A.; Palacios, E.

    1987-01-01

    This work analyzes, by a simplified model, the radiological impact due to radioactive wastes release when engineering and geologic barriers individually fail. Doses are calculated resulting from the individuals of a hypothetical critical group and the potential collective dosis for each one of the considered situations. (Author) [es

  15. Monitoring of the radiological environmental impact of the AREVA site of Tricastin

    International Nuclear Information System (INIS)

    Mercat, C.; Brun, F.; Florens, P.; Petit, J.; Garnier, F.; Devin, P.

    2010-01-01

    Set up at the beginning of the site's operations, in 1962, the monitoring of the radiological environmental impact of the AREVA site of Tricastin has evolved over time to meet more specifically the multiple objectives of environmental monitoring: to prove the respect of the commitments required by the authorities, to be able to detect a dysfunction in the observed levels, to enable the assessment of impacts of industrial activities, to ensure the balance between environmental quality and the use made by the local population and to inform the public of the radiological state of the environment. Thousands of data were acquired on the radioactivity of all environmental compartments as well as on the functioning of local ecosystems. Today, the Network of Environmental Monitoring of AREVA Tricastin goes beyond the requirements of routine monitoring to provide innovative solutions for monitoring the radioactivity (especially for uranium) in the environment. (author)

  16. Radiological impact assessment in Malaysia using RESRAD computer code

    International Nuclear Information System (INIS)

    Syed Hakimi Sakuma Syed Ahmad; Khairuddin Mohamad Kontol; Razali Hamzah

    1999-01-01

    Radiological Impact Assessment (RIA) can be conducted in Malaysia by using the RESRAD computer code developed by Argonne National Laboratory, U.S.A. The code can do analysis to derive site specific guidelines for allowable residual concentrations of radionuclides in soil. Concepts of the RIA in the context of waste management concern in Malaysia, some regulatory information and assess status of data collection are shown. Appropriate use scenarios and site specific parameters are used as much as possible so as to be realistic so that will reasonably ensure that individual dose limits and or constraints will be achieved. Case study have been conducted to fulfil Atomic Energy Licensing Board (AELB) requirements where for disposal purpose the operator must be required to carry out. a radiological impact assessment to all proposed disposals. This is to demonstrate that no member of public will be exposed to more than 1 mSv/year from all activities. Results obtained from analyses show the RESRAD computer code is able to calculate doses, risks, and guideline values. Sensitivity analysis by the computer code shows that the parameters used as input are justified so as to improve confidence to the public and the AELB the results of the analysis. The computer code can also be used as an initial assessment to conduct screening assessment in order to determine a proper disposal site. (Author)

  17. Quality control of diagnostic radiology to reduce absorbed dose of patients in Iran

    International Nuclear Information System (INIS)

    Aghahadi, Bahman.

    1996-01-01

    In order to reduce absorbed dose, to increase the image quality and to reduce the numbers of rejected films various quality control parameters were applied to X ray machines. These parameter are Kilo Volt peak, Milli Ampere, Exposure Time Focal Film Distance, Inherent Filters, Additional Filters Half Value Layer, Processor Condition, Cassettes. To evaluate and to apply these parameters in diagnostic radiological centers, ten hospitals were selected and a total number of 12 X ray machines were kept under quality control program. Considering different kinds of diagnostic radiology examination and to compare the dose before and after implementation of a quality control program, two kinds of examinations include in chest and abdomen examinations were considered. For each X ray machine, ten patients and for all selected centers, 120 patients were selected for chest examination and 120 patients for abdomen examinations; before and after implementation of quality control program, a total of 480 patients were selected randomly to be controlled. Base on different examinations carried out, it was concluded that both exposure conditions and general situations in radiological centers were not acceptable. The dosimetry results show that the average ski dose for chest and abdomen examinations were 0.28 m Gy and 4.23 Gy respectively. Before implementation of quality control step to reduce the surface skin dose, quality control parameters were applied and the exposure conditions were imposed. On average the absorbed doses for chest and abdomen examination were decreased to 79% and 61% respectively after the implementation of the program. From dose reduction point of view, the results of a part of this project which made by co-operation of International Atomic Energy Agency showed that Iran acquired the first grade for chest examination and second grade for abdomen examination. Base on the results obtained, the number of patients under chest and abdomen examination were 4041588 and

  18. The quality and impact of computer supported collaborative learning (CSCL) in radiology case-based learning

    International Nuclear Information System (INIS)

    Kourdioukova, Elena V.; Verstraete, Koenraad L.; Valcke, Martin

    2011-01-01

    Objective: The aim of this research was to explore (1) clinical years students' perceptions about radiology case-based learning within a computer supported collaborative learning (CSCL) setting, (2) an analysis of the collaborative learning process, and (3) the learning impact of collaborative work on the radiology cases. Methods: The first part of this study focuses on a more detailed analysis of a survey study about CSCL based case-based learning, set up in the context of a broader radiology curriculum innovation. The second part centers on a qualitative and quantitative analysis of 52 online collaborative learning discussions from 5th year and nearly graduating medical students. The collaborative work was based on 26 radiology cases regarding musculoskeletal radiology. Results: The analysis of perceptions about collaborative learning on radiology cases reflects a rather neutral attitude that also does not differ significantly in students of different grade levels. Less advanced students are more positive about CSCL as compared to last year students. Outcome evaluation shows a significantly higher level of accuracy in identification of radiology key structures and in radiology diagnosis as well as in linking the radiological signs with available clinical information in nearly graduated students. No significant differences between different grade levels were found in accuracy of using medical terminology. Conclusion: Students appreciate computer supported collaborative learning settings when tackling radiology case-based learning. Scripted computer supported collaborative learning groups proved to be useful for both 5th and 7th year students in view of developing components of their radiology diagnostic approaches.

  19. The quality and impact of computer supported collaborative learning (CSCL) in radiology case-based learning.

    Science.gov (United States)

    Kourdioukova, Elena V; Verstraete, Koenraad L; Valcke, Martin

    2011-06-01

    The aim of this research was to explore (1) clinical years students' perceptions about radiology case-based learning within a computer supported collaborative learning (CSCL) setting, (2) an analysis of the collaborative learning process, and (3) the learning impact of collaborative work on the radiology cases. The first part of this study focuses on a more detailed analysis of a survey study about CSCL based case-based learning, set up in the context of a broader radiology curriculum innovation. The second part centers on a qualitative and quantitative analysis of 52 online collaborative learning discussions from 5th year and nearly graduating medical students. The collaborative work was based on 26 radiology cases regarding musculoskeletal radiology. The analysis of perceptions about collaborative learning on radiology cases reflects a rather neutral attitude that also does not differ significantly in students of different grade levels. Less advanced students are more positive about CSCL as compared to last year students. Outcome evaluation shows a significantly higher level of accuracy in identification of radiology key structures and in radiology diagnosis as well as in linking the radiological signs with available clinical information in nearly graduated students. No significant differences between different grade levels were found in accuracy of using medical terminology. Students appreciate computer supported collaborative learning settings when tackling radiology case-based learning. Scripted computer supported collaborative learning groups proved to be useful for both 5th and 7th year students in view of developing components of their radiology diagnostic approaches. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  20. Impact on Quality When Pediatric Urgent Care Centers Are Staffed With Radiology Technologists.

    Science.gov (United States)

    Kan, J Herman; Orth, Robert C; Yen, Terry A; Schallert, Erica K; Zhang, Wei; Donnelly, Lane F

    2018-02-02

    The proliferation of pediatric urgent care centers has increased the need for diagnostic imaging support, but the impact of employing radiology technologists at these centers is not known. The purpose of this study was to evaluate radiographic impact and quality at urgent care centers with and without radiology technologists. A retrospective case-control study was conducted comparing 235 radiographic examinations (study) performed without and 83 examinations (control) performed with a radiology technologist at the authors' pediatric urgent care centers. Studies were evaluated for quality using a five-point, Likert-type scale (1 = poor, 5 = best) regarding field of view, presentation, and orthogonal view orientation. Studies were also evaluated for the incidence of positive results, need for repeat imaging, and discrepancies between initial study and follow-up. Imaging quality comparisons between study and control groups were statistically different for field of view (3.98 versus 4.29, P = .014), presentation (4.39 versus 4.51, P = .045), and orthogonal view orientation (4.45 versus 4.69, P = .033). The incidence of repeat imaging was similar (4.7% versus 2.4%, P = 0.526), as well as the discrepancy rates (3.4 versus 2.4%, P = 1.00). The incidence of abnormal radiographic findings for the study and control groups was similar (40.9% versus 34.9%, P = .363). Radiography is an important triage tool at pediatric urgent care centers. It is imperative to have optimal radiographic imaging for accurate diagnosis, and imaging quality is improved when radiology technologists are available. If not feasible or cost prohibitive, it is important that physicians be given training opportunities to bridge the quality gap when using radiographic equipment and exposing children to radiation. Copyright © 2018 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  1. The effects of actinide separation on the radiological consequences of geologic disposal of high-level waste

    International Nuclear Information System (INIS)

    Hill, M.D.; White, I.F.; Fleishman, A.B.

    1980-01-01

    It has often been suggested that the potential hazard to man from the disposal of high-level radioactive waste could be reduced by removing a substantial fraction of the actinide elements. In this report the effects of actinide separation on the radiological consequences of one of the disposal options currently under consideration, that of burial in deep geologic formations, are examined. The results show that the potential radiological impact of geologic disposal of high-level waste arises from both long-lived fission products and actinides (and their daughter radionuclides). Neither class of radionuclides is of overriding importance and actinide separation would therefore reduce the radiological impact to only a limited extent and over limited periods. There might be a case for attempting to reduce doses from 237 Np. To achieve this it appears to be necessary to separate both neptunium and its precursor element americium. However, there are major uncertainties in the data needed to predict doses from 237 Np; further research is required to resolve these uncertainties. In addition, consideration should be given to alternative methods of reducing the radiological impact of geologic disposal. The conclusions of this assessment differ considerably from those of similar studies based on the concept of toxicity indices. Use of these indices can lead to incorrect allocation of research and development effort. (author)

  2. Radiological impact assessment of the domestic on-road transportation of radioactive isotope wastes

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Myung Hwan; Hong, Sung Wook; Park, Jin Beak [Korea Radioactive Waste Agency, Technology Institute, Daejeon (Korea, Republic of)

    2016-09-15

    Korea Radioactive Waste Agency (KORAD) began to operate the low and intermediate level radioactive waste disposal facility in Gyeongju and to transport the radioactive waste containing radioactive isotopes from Daejeon to the disposal facility for the first time at 2015. For this radioactive waste transportation, in this study, radiological impact assessment is carried out for workers and public. The dose rate to workers and public during the transportation is estimated with consideration of the transportation scenarios and is compared with the Korean regulatory limit. The sensitivity analysis is carried out by considering both the variation of release ratios of the radioactive isotopes from the waste and the variation of the distances between the radioactive waste drum and worker during loading and unloading of radioactive waste. As for all the transportation scenarios, radiological impacts for workers and public have met the regulatory limits.

  3. Evaluation of the atmospheric stability and it influence in the radiological environmental impact of the treatment plant and radioactive waste storage (PTDR)

    International Nuclear Information System (INIS)

    Ramos V, E.O.; Cornejo D, N.

    2006-01-01

    It is well-known that the meteorological variables as the atmospheric stability, influence in the atmospheric dispersion of radioactive pollutants, for that as regards radiological safety, it constitutes a demand the evaluation of their impact in the process before mentioned. The present work exposes the results of the study of the radiological impact of our PTDR that it allowed to know the influence of this meteorological parameter in the atmospheric dispersion of radioactive pollutants in its location. To such effects they were processed by means of the methodology of Pasquill - Gifford, data of time zone observations of this meteorological variable obtained in the proximities of the installation, being modeled the worst conditions in atmospheric liberation of their radionuclides inventory, valuing stops the 2 critical considered population groups the doses received by inhalation of polluted air and ingestion of water and polluted products, as well as, for external irradiation from the radioactive cloud and the floor. The obtained annual effective doses due to the modeling situation reach until a mSv, except for the Ra-226 that are lightly superior, implying a risk radiological acceptable chord to the international standard. To the above-mentioned a reduced probability of occurrence of events initiators of the evaluated accidental sequence is added. (Author)

  4. Radiological clerkships as a critical curriculum component in radiology education

    International Nuclear Information System (INIS)

    Kourdioukova, Elena V.; Verstraete, Koenraad L.; Valcke, Martin

    2011-01-01

    Objective: The aim of this research was to explore the perceived value of clinical clerkships in the radiology curriculum as well as the impact of radiology clerkship on students' beliefs about the profession of radiology as a whole and as a career. Methods: This study is a sequel to a previous survey in which student perceptions about radiology curriculum components were investigated. The present study focuses on a further analysis of a subsection in this study, based on 14 statements about radiology clerkship and two statements about radiology as a career. Results: Perceived usefulness of the aspects of radiology clerkship as 'radiology examination', 'skills development' and 'diagnosis focus' were awarded the highest scores. The predict value of the subscale 'radiology examination' on the level of performance was very high (adjusted R 2 = 0.19, p < .001). Conclusion: Students expressed highly favorable evaluation of clerkship as a learning environment to learn to order and to interpret imaging studies as well as an unique possibility to attend various radiological examinations and to access to specific radiology software systems, as well as to get a better view on radiology and to improve image interpretation skills. This positive attitude towards clerkship is closely tied to students' beliefs about the profession of radiology as a whole. These aspects of dedicated radiology clerkship are crucial for effective and high-quality education as well as for the choice of radiology as a career.

  5. Radiological impact of surface water and sediment near uranium mining sites.

    Science.gov (United States)

    Ivanova, K; Stojanovska, Z; Badulin, V; Kunovska, B; Yovcheva, M

    2015-12-01

    The aim of this study is to assess the radiological impact of surface water and sediment around uranium mining sites 20 years after their closing. The areas under observations are 31 former classical underground uranium mining and exploratory sites in Bulgaria, named as objects. The extraction and processing of uranium ores in the Republic of Bulgaria were ended in 1992. To assess the radiological impact of radionuclides field expeditions were performed to sample water and bottom sediment. The migration of uranium through surface water was examined as one of the major pathways for contamination spread. The range of uranium concentration in water flowing from the mining sites was from 0.012 to 6.8 mgU l(-1) with a geometric mean of 0.192 mgU l(-1). The uranium concentrations in water downstream the mining sites were approximately 3 times higher than the background value (upstream). The concentrations of Unat, (226)Ra, (210)Pb, and (232)Th in the sediment of downstream river were higher than those upstream by 3.4, 2.6, 2, and 1.7 times, respectively. The distribution coefficient of uranium reflects its high mobility in most of the sites. In order to evaluate the impact on people as well as site prioritization for more detailed assessment and water management, screening dose assessments were done.

  6. Dirty bombs: assesment of radiological impacts

    International Nuclear Information System (INIS)

    Trifunovic, D.; Koukouliou, V.

    2009-01-01

    In some countries, regulatory control of radioactive sources, used extensively in medicine and industry, remains weak. Global concerns about the security and safety of radioactive sources escalated following the September 11 2001 terrorist attacks in the United States. There are fears that some radioactive sources could be used by terrorists as radiological dispersal devices (RDD's), or so called 'dirty bombs'. The radioactive material dispersed, depending on the amount and intensity, could cause radiation sickness for a limited number of people nearby if, for example, they inhaled large amounts of radioactive dust. But the most severe tangible impacts would likely be the economic costs and social disruption associated with the evacuation and subsequent clean-up of contaminated property. It has been shown that usage of realistic data in a first response decision making as to avoid inappropriate public reaction accompanied by economic and social consequences is necessary.(author)

  7. Radiological health review of the final environmental impact statement. Waste Isolation Pilot Plant. Volumes 1 and 2

    International Nuclear Information System (INIS)

    1981-01-01

    Pursuant to the requirements of the National Environmental Policy Act of 1969, the Department of Energy has provided in the Final Environmental Impact Statement (FEIS) a comprehensive review of the potential radiological impact of the proposed Waste Isolation Pilot Plant, referred to in the FEIS as, the authorized alternative. The EEG has reviewed this document to determine (a) the changes made in comparison with the Draft Environmental Impact Statement (DEIS); (b) the adequacy of the DOE's evaluation of the potential radiological impact; (c) the thoroughness of the DOE's response to the comments of the EEG on the DEIS; and (d) other issues which should be addressed by DOE more fully prior to beginning construction of the WIPP. Based on our review of the FEIS, the Department of Energy has incorporated and addressed the majority of the concerns, questions and recommendations that the EEG provided to them in our August 1979 review of the Draft Environmental Impact Statement on WIPP and the FEIS provides a generally satisfactory evaluation of the potential radiological impact. There are, however, a number of areas that have yet to be adequately treated by DOE and should be acted upon and resolved prior to beginning construction of the WIPP. The more important issues are included and are discussed in more detail in our December 8, 1980 and January 15, 1981 comments on the FEIS

  8. Radiological impacts of spent nuclear fuel management options. A comparative study

    International Nuclear Information System (INIS)

    2000-01-01

    Given its potential significance for public health and the environment, the impact of radioactive releases during important steps of nuclear energy production must be considered when selecting among different fuel cycles. With this in mind, the OECD Nuclear Energy Agency (NEA) has undertaken a comparative study to the radiological impacts of two main fuel cycle options : one with and one without reprocessing of spent nuclear fuel. The study compares the respective impacts of the two options based on generic models and assumptions as well as actual data. It concludes that the difference between them is not significant. A wealth of recent data assembled and evaluated by an international expert team is provided in annex. (authors)

  9. Potential radiological impacts of upper-bound operational accidents during proposed waste disposal alternatives for Hanford defense waste

    Energy Technology Data Exchange (ETDEWEB)

    Mishima, J.; Sutter, S.L.; Hawley, K.A.; Jenkins, C.E.; Napier, B.A.

    1986-02-01

    The Geologic Disposal Alternative, the In-Place Stabilization and Disposal Alternative, and the Reference Disposal Alternative are being evaluated for disposal of Hanford defense high-level, transuranic, and tank wastes. Environmental impacts associated with disposal of these wastes according to the alternatives listed above include potential doses to the downwind population from operation during the application of the handling and processing techniques comprising each disposal alternative. Scenarios for operational accident and abnormal operational events are postulated, on the basis of the currently available information, for the application of the techniques employed for each waste class for each disposal alternative. From these scenarios, an upper-bound airborne release of radioactive material was postulated for each waste class and disposal alternative. Potential downwind radiologic impacts were calculated from these upper-bound events. In all three alternatives, the single postulated event with the largest calculated radiologic impact for any waste class is an explosion of a mixture of ferri/ferro cyanide precipitates during the mechanical retrieval or microwave drying of the salt cake in single shell waste tanks. The anticipated downwind dose (70-year dose commitment) to the maximally exposed individual is 3 rem with a total population dose of 7000 man-rem. The same individual would receive 7 rem from natural background radiation during the same time period, and the same population would receive 3,000,000 man-rem. Radiological impacts to the public from all other postulated accidents would be less than that from this accident; furthermore, the radiological impacts resulting from this accident would be less than one-half that from the natural background radiation dose.

  10. Potential radiological impacts of upper-bound operational accidents during proposed waste disposal alternatives for Hanford defense waste

    International Nuclear Information System (INIS)

    Mishima, J.; Sutter, S.L.; Hawley, K.A.; Jenkins, C.E.; Napier, B.A.

    1986-02-01

    The Geologic Disposal Alternative, the In-Place Stabilization and Disposal Alternative, and the Reference Disposal Alternative are being evaluated for disposal of Hanford defense high-level, transuranic, and tank wastes. Environmental impacts associated with disposal of these wastes according to the alternatives listed above include potential doses to the downwind population from operation during the application of the handling and processing techniques comprising each disposal alternative. Scenarios for operational accident and abnormal operational events are postulated, on the basis of the currently available information, for the application of the techniques employed for each waste class for each disposal alternative. From these scenarios, an upper-bound airborne release of radioactive material was postulated for each waste class and disposal alternative. Potential downwind radiologic impacts were calculated from these upper-bound events. In all three alternatives, the single postulated event with the largest calculated radiologic impact for any waste class is an explosion of a mixture of ferri/ferro cyanide precipitates during the mechanical retrieval or microwave drying of the salt cake in single shell waste tanks. The anticipated downwind dose (70-year dose commitment) to the maximally exposed individual is 3 rem with a total population dose of 7000 man-rem. The same individual would receive 7 rem from natural background radiation during the same time period, and the same population would receive 3,000,000 man-rem. Radiological impacts to the public from all other postulated accidents would be less than that from this accident; furthermore, the radiological impacts resulting from this accident would be less than one-half that from the natural background radiation dose

  11. Radiological impact of oil and Gas Activities in selected oil fields in ...

    African Journals Online (AJOL)

    Log in or Register to get access to full text downloads. ... A study of the radiological impact of oil and gas exploration activities in the production land area of Delta ... the public and non-nuclear industrial environment, while the levels for the fields at Otorogu, Ughelli West, ... EMAIL FREE FULL TEXT EMAIL FREE FULL TEXT

  12. The radiological impact on the Greater London population of postulated accidental releases from the Sizewell PWR

    CERN Document Server

    Kelly, G N; Charles, D; Hemming, C R

    1983-01-01

    This report contains an assessment of the radiological impact on the Greater London population of postulated accidental releases from the Sizewell PWR. Three of the degraded core accident releases postulated by the CEGB are analysed. The consequences, conditional upon each release, are evaluated in terms of the health impact on the exposed population and the impact of countermeasures taken to limit the exposure. Consideration is given to the risk to the Greater London population as a whole and to individuals within it. The consequences are evaluated using the NRPB code MARC (Methodology for Assessing Radiological Consequences). The results presented in this report are all conditional upon the occurrence of each release. In assessing the significance of the results, due account must be taken of the frequency with which such releases may be predicted to occur.

  13. The radiological impact associated with the recycling of actinides and fission products. A global assessment

    International Nuclear Information System (INIS)

    Dodd, D.H.

    1996-05-01

    This report describes the results of a literature study performed to identify any significant differences in the public radiological impact associated with existing nuclear fuel cycles and partitioning and transmutation (P and T) based fuel cycles. The study was performed in the framework of ECN Nuclear Energy's RAS (Recyclage van Actiniden en Splijtingsprodukten) research programme. Two reference 'once through' cycles and five 'advanced' fuel cycles were analysed. The five 'advanced' fuel cycles all incorporate technologies for the partitioning and transmutation of the long-lived radionuclides present in high level radioactive waste. Currently, only a limited amount of information on these 'advanced' fuel cycles is available. The assessment of the radiological impact associated with these cycles is therefore by necessity of a general nature. (orig./WL)

  14. Science and values in radiological protection: impact on radiological protection decision making

    International Nuclear Information System (INIS)

    Salomaa, Sisko; Pinak, Miroslav

    2008-01-01

    Full text: This work summarises the main ideas and achievements of the Science and Values in Radiological Protection Workshop that was held on 15-17 January 2008 in Helsinki, Finland. In the view of developing of new radiological applications and emerging scientific phenomena it has been recognized a need to develop a shared understanding of emerging challenges for radiological protection among scientific and regulatory communities, public and other concerned stake holders. In response to this the Committee of Radiation Protection and Public Health of the OECD Nuclear Energy Agency and Radiation and Nuclear Safety Authority of Finland tried to initiate a process of longer-term reflection on scientific and societal issues that might challenge radiological protection in the coming years. Among general issues like radiological policy issues, improvement of understanding between research and policy communities, sharing views on emerging scientific issues, there were addressed several scientific issues, like non-targeted effects, individual sensitivity; and circulatory diseases. The main focus of these discussions was to elaborate potential 'what if' scenarios and propose feasible solutions at various levels. These discussions addressed effects that are not direct and evident consequence of the initial lesions produced at the cellular and DNA level like bystander responses, genomic instability, gene induction, adaptive responses and low dose. Particular interest was paid to an extrapolation of risk estimates to low doses and role of Linear Non-Threshold theory in setting regulatory principles. Individual radio-sensitivity and identification of genes that are suspected of having an influence on it were also discussed in one of the Breakout Sessions. Another Breakout Session addressed circulatory diseases. There is emerging evidence in the A-bomb survivors and in other exposed groups that ionising radiation also causes other diseases than cancer, such as circulatory

  15. Radiological controls integrated into design

    Energy Technology Data Exchange (ETDEWEB)

    Kindred, G.W. [Cleveland Electric Illuminating Co., Perry, OH (United States)

    1995-03-01

    Radiological controls are required by law in the design of commercial nuclear power reactor facilities. These controls can be relatively minor or significant, relative to cost. To ensure that radiological controls are designed into a project, the health physicist (radiological engineer) must be involved from the beginning. This is especially true regarding keeping costs down. For every radiological engineer at a nuclear power plant there must be fifty engineers of other disciplines. The radiological engineer cannot be an expert on every discipline of engineering. However, he must be knowledgeable to the degree of how a design will impact the facility from a radiological perspective. This paper will address how to effectively perform radiological analyses with the goal of radiological controls integrated into the design package.

  16. Radiological impact of plutonium recycle in the fuel cycle of LWR type reactors: professional exposure during mormal operation

    International Nuclear Information System (INIS)

    White, I.F.; Kelly, G.N.

    1983-01-01

    The radiological impact of the fuel cycle of light water type reactors using enriched uranium may be changed by plutonium recycle. The impact on human population and on the persons professionally exposed may be different according to the different steps of the fuel cycle. This report analyses the differential radiological impact on the different types of personnel involed in the fuel cycle. Each step of the fuel cycle is separately studied (fuel fabrication, reactor operation, fuel reprocessing), as also the transport of the radioactive materials between the different steps. For the whole fuel cycle, one estimates that, with regard to the fuel cycle using enriched uranium, the plutonium recycle involves a small increase of the professional exposure

  17. Unenhanced computed tomography in acute renal colic reduces cost outside radiology department

    DEFF Research Database (Denmark)

    Lauritsen, J.; Andersen, J.R.; Nordling, J.

    2008-01-01

    BACKGROUND: Unenhanced multidetector computed tomography (UMDCT) is well established as the procedure of choice for radiologic evaluation of patients with renal colic. The procedure has both clinical and financial consequences for departments of surgery and radiology. However, the financial effect...... outside the radiology department is poorly elucidated. PURPOSE: To evaluate the financial consequences outside of the radiology department, a retrospective study comparing the ward occupation of patients examined with UMDCT to that of intravenous urography (IVU) was performed. MATERIAL AND METHODS......) saved the hospital USD 265,000 every 6 months compared to the use of IVU. CONCLUSION: Use of UMDCT compared to IVU in patients with renal colic leads to cost savings outside the radiology department Udgivelsesdato: 2008/12...

  18. A Vertically Integrated Online Radiology Curriculum Developed as a Cognitive Apprenticeship: Impact on Student Performance and Learning.

    Science.gov (United States)

    Lim-Dunham, Jennifer E; Ensminger, David C; McNulty, John A; Hoyt, Amy E; Chandrasekhar, Arcot J

    2016-02-01

    The principles of Collins' cognitive apprenticeship model were used to design a radiology curriculum in which medical students practice radiological skills using online case-based modules. The modules are embedded within clinical third-year clerkships, and students are provided with personalized feedback from the instructors. We describe the development of the vertical online radiology curriculum and evaluate its impact on student achievement and learning process using a mixed method approach. The curriculum was developed over a 2-year period. Student participation was voluntary in the first year and mandatory in the second year. For quantitative curriculum evaluation, student metrics for voluntary versus mandatory groups were assessed using independent sample t tests and variable entry method regression analysis. For qualitative analysis, responses from a survey of students about the value of the curriculum were organized into defined themes using consensus coding. Mandatory participation significantly improved (p = .001) the mean radiology examination score (82 %) compared to the voluntary group (73%), suggesting that mandatory participation had a beneficial effect on student performance. Potential preexisting differences in underlying general academic performance were accounted for by including mean basic science grades as the first variable in the regression model. The significant increase in R(2) from .16 to .28 when number of radiology cases completed was added to the original model, and the greater value of the standardized beta for this variable, suggest that the curriculum made a significant contribution to students' radiology examination scores beyond their baseline academic performance. Five dominant themes about curricular characteristics that enhanced student learning and beneficial outcomes emerged from consensus coding. These themes were (1) self-paced design, (2) receiving feedback from faculty, (3) clinical relevance of cases, (4) gaining

  19. Radiological impact assessment of building materials on ordinary houses dwellers

    International Nuclear Information System (INIS)

    Campos, M.P. de.

    1994-01-01

    The radiological impact due to building materials on habitants living in the Santo Andre district of Sao Paulo state, Brazil, was assessed through the total effective dose equivalent rate determination, for external and internal irradiation. The effective dose equivalent rate for external irradiation was calculated by the gamma spectrometry determination of natural radionuclides specific activity in the dwelling materials. The effective dose equivalent rate due to 222 Rn inhalation was calculated through the radon indoor activity determination by using solid state nuclear track detectors. (author). 46 refs, 6 figs, 14 tabs

  20. Impact of Simulation-Based Training on Radiology Trainee Education in Ultrasound-Guided Breast Biopsies.

    Science.gov (United States)

    Roark, Ashley A; Ebuoma, Lilian O; Ortiz-Perez, Tamara; Sepulveda, Karla A; Severs, Frederick J; Wang, Tao; Benveniste, Ana Paula; Sedgwick, Emily L

    2017-12-05

    The aim of this study is to determine the impact of a simulation-based ultrasound-guided (USG) breast biopsy training session on radiology trainee procedural knowledge, comfort levels, and overall procedural confidence and anxiety. Twenty-one diagnostic radiology residents from a single academic institution were recruited to participate in an USG breast biopsy training session. The residents filled out a questionnaire before and after the training session. Ten multiple-choice questions tested general knowledge in diagnostic breast ultrasound and USG breast biopsy concepts. Subjective comfort levels with ultrasound machine and biopsy device functionality, patient positioning, proper biopsy technique, image documentation, needle safety and overall procedural confidence and anxiety levels were reported on a 5-point Likert scale before and after training. Participants demonstrated significant improvement in number of correctly answered general knowledge questions after training (P simulation-based USG breast biopsy training session may improve radiology trainee procedural knowledge, comfort levels, and overall procedural confidence. Copyright © 2017 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  1. The radiological impact of the LEP project on the environment

    International Nuclear Information System (INIS)

    Goebel, K.

    1981-01-01

    The siting of the large electron-positron (LEP) accelerator, its experimental areas, and its supporting infrastructure are discussed with respect to the radiological impact on the surrounding areas and on the population in the Pays de Gex and the Canton de Geneve. The final conclusions are based on work done by the former LEP Study Group and by the LEP Radiation Working Group. The calculations and estimates show that the stray ionizing radiation, the radioactivity, and the radiation-induced noxious chemical products released by the LEP installation will have only an insignificant impact on the area, the individual members of the public, and the population as a whole. This result for LEP 'phase 85' can also be extrapolated under reasonable assumptions for LEP 125 - a possible future development phase of the present project. (orig.)

  2. The evolution of radiology information management

    International Nuclear Information System (INIS)

    Patacsil, L.

    2002-01-01

    Aim: The use of PACS and the need for images and clinical data is increasing exponentially. This presentation will provide a historical overview of radiology information systems (RIS) and their interaction with hospital information systems (HIS), PACS systems and modalities. Materials and Methods: The various approaches to interfacing and integrating RIS and PACS systems will be described as well as their impact on radiology departmental work-flow and the productivity of radiologists, technologists and other RIS users. Specifically, the image-centric and RIS-centric approaches to PACS will be compared. Results: Instant access to vital clinical information enables radiology departments to go beyond simply managing processes to making fundamental improvements in productivity and care processes. Unity of design translates into simplicity of operations. Integration of historically separate applications makes the environment easier to support, reduces turnaround time, and improves patient care. Conclusion: Finally, insight on new technologies and future trends in PACS, system integration and work-flow strategies will be presented in light of delivery of both clinical images and clinical data

  3. Age dependent food consumption data provided for the computation of the radiological impact via the ingestion pathway

    International Nuclear Information System (INIS)

    Kalckbrenner, R.; Bayer, A.

    1979-08-01

    Averaged age dependent food consumption data are compiled and evaluated to provide input data for the computation of the radiological impact via the ingestion pathway. For special population groups (self-suppliers e.g.) factors are provided, by which the consumption for special foods may be exceeded. The evaluated data are compared with those of the 'USNRC-Regulatory Guide 1.109 (revised 1977)' and those of the 'Recommendation of the German Commission on Radiological Protection (Draft 1977)'. (orig.) [de

  4. RADRELAY RADIOLOGICAL DATA LINK DEVICE

    International Nuclear Information System (INIS)

    Harpring, L.; Frank Heckendorn, F.

    2007-01-01

    The RadRelay effort developed small, field appropriate, portable prototype devices that allow radiological spectra to be downloaded from field radiological detectors, like the identiFINDER-U, and transmitted to land based experts. This communications capability was designed for the U. S. Coast Guard (USCG) but is also applicable to the Customs and Border Protection (CBP) personnel working in remote locations. USCG Level II personnel currently use the identiFINDER-U Hand-Held Radioisotope ID Devices (HHRIID) to detect radiological materials during specific boarding operations. These devices will detect not only radiological emissions but will also evaluate those emissions against a table of known radiological spectra. The RadRelay has been developed to significantly improve the functionality of HHRIID, by providing the capability to download radiological spectra and then transmit them using satellite or cell phone technology. This remote wireless data transfer reduces the current lengthy delay often encountered between the shipboard detection of unknown radiological material and the evaluation of that data by technical and command personnel. That delay is reduced from hours to minutes and allows the field located personnel to remain on station during the inspection and evaluation process

  5. The Impact Factor of Radiological Journals: Associations with Journal Content and Other Characteristics Over a Recent 12-Year Period.

    Science.gov (United States)

    Rosenkrantz, Andrew B; Ayoola, Abimbola

    2016-06-01

    The aim of this study was to evaluate the trends in the impact factor (IF) of radiological journals over a recent 12-year period, including associations between IF and journal topic. Journal Citation Reports (JCR) was used to identify all biomedical journals and all radiological journals (assigned a JCR category of "Radiology, Nuclear Medicine, & Medical Imaging"), along with journal IF, in 2003 and 2014. Radiological journals were manually classified by topic. Trends in median IF (mIF) were assessed. The number of radiological journals increased from 83 (2003) to 125 (2014) (all biomedical journals: 5907 to 8718, respectively). mIF of radiological journals increased from 1.42 (2003) to 1.75 (2014) (all biomedical journals: 0.93 to 1.46, respectively). The most common topic among new radiological journals was general (nonspecialized) radiology (8). Five new radiological journals in 2014 were in topics (cancer imaging and molecular imaging) having no journals in 2003. mIF of general radiological journals was 1.49. Topics having highest mIF were cardiac imaging (2.94), optics (2.86), molecular imaging (2.77), radiation oncology (2.60), and neuroradiology (2.25). Topics with lowest mIF were ultrasound (1.19) and interventional radiology (1.44). Topics with the largest increase in mIF were cardiac imaging (from 1.17 to 2.94) and neuroradiology (from 1.07 to 2.25). Radiological journals exhibited higher mIF than biomedical journals overall. Among radiological journals, subspecialty journals had highest mIF. While a considerable number of new radiological journals since 2003 were general radiology journals having relatively low IF, there were also new journal topics representing emerging areas of subspecialized radiological research. Copyright © 2016 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  6. Generic environmental impact statement in support of rulemaking on radiological criteria for license termination of NRC-licensed nuclear facilities. Final report, main report

    International Nuclear Information System (INIS)

    1997-07-01

    The action being considered in this Final Generic Environmental Impact Statement (GEIS) is an amendment to the Nuclear Regulatory Commission's (NRC) regulations in 10 CFR Part 20 to include radiological criteria for decommissioning of lands and structures at nuclear facilities. Under the National Environmental Policy Act (NEPA), all Federal agencies must consider the effect of their actions on the environment. To fulfill NRC's responsibilities under NEPA, the Commission is preparing this GEIS which analyzes alternative courses of action and the costs and impacts associated with those alternatives. In preparing the final GEIS, the following approach was taken: (1) a listing was developed of regulatory alternatives for establishing radiological criteria for decommissioning; (2) for each alternative, a detailed analysis and comparison of incremental impacts, both radiological and nonradiological, to workers, members of the public, and the environment, and costs, were performed; and (3) based on the analysis of impacts and costs, conclusions on radiological criteria for decommissioning were provided. Contained in the GEIS are results and conclusions related to achieving, as an objective of decommissioning ALARA, reduction to preexisting background, the radiological criterion for unrestricted use, decommissioning ALARA analysis for soils and structures containing contamination, restricted use and alternative analysis for special site specific situations, and groundwater cleanup. In its analyses, the final GEIS includes consideration of comments made on the draft GEIS during the public comment period

  7. Radiological impact from airborne routine discharges of Coal-Fired power plant

    International Nuclear Information System (INIS)

    Norasalwa Zakaria; Rohyiza Baan; Kathiravale, Sivapalan

    2010-01-01

    Radioactivity exists everywhere in nature. We are exposed to intense and continuous natural radiation coming from the sun, cosmic radiation, telluric radiation and even to the internal radiation of our own body. The fly ash emitted from burning coal for electricity by a power plant carries into the surrounding environment 100 times more radiation than a nuclear power plant producing the same amount of energy. This paper presents the information of studies on the radiological impact from airborne routine discharge of coal-fired power plants. (author)

  8. The positive impact of radiologic imaging on high-stage cutaneous squamous cell carcinoma management.

    Science.gov (United States)

    Ruiz, Emily Stamell; Karia, Pritesh S; Morgan, Frederick C; Schmults, Chrysalyne D

    2017-02-01

    There is limited evidence on the utility of radiologic imaging for prognostic staging of cutaneous squamous cell carcinoma (CSCC). Review utilization of radiologic imaging of high-stage CSCCs to evaluate whether imaging impacted management and outcomes. Tumors classified as Brigham and Women's Hospital (BWH) tumor (T) stage T2B or T3 over a 13-year period were reviewed to identify whether imaging was performed and whether results affected treatment. Disease-related outcomes (DRO: local recurrence, nodal metastasis, death from disease) were compared between patients by type of imaging used. 108 high-stage CSCCs in 98 patients were included. Imaging (mostly computed tomography, 79%) was utilized in 45 (46%) patients and management was altered in 16 (33%) patients who underwent imaging. Patients that received no imaging were at higher risk of developing nodal metastases (nonimaging, 30%; imaging, 13%; P = .041) and any DRO (nonimaging, 42%; imaging, 20%; P = .028) compared to the imaging group. Imaging was associated with a lower risk for DRO (subhazard ratio, 0.5; 95% CI 0.2-0.9; P = .046) adjusted for BWH T stage, sex, and location. Single institution retrospective design and changes in technology overtime. Radiologic imaging of high-stage CSCC may influence management and appears to positively impact outcomes. Further prospective studies are needed to establish which patients benefit from imaging. Copyright © 2016 American Academy of Dermatology, Inc. Published by Elsevier Inc. All rights reserved.

  9. Radiological impact of radioactive waste management

    International Nuclear Information System (INIS)

    Beninson, D.J.; Migliori de Beninson, Ambreta.

    1985-01-01

    The radiological impacts from management of wastes from the nuclear fuel cycle have been estimated for several alternative fuel cycle strategies. The impacts are expressed as collective effective dose equivalent commitments. Mill tailings make an important contribution, which depends on the uranium requirements for each reference fuel cycle, being the largest for once-through cycles. Disposal of high level waste or spent fuel is also an important contribution, usually larger for once-through cycle where the entire actinide inventory is disposed off. Although at present conversion and enrichment tailing are not considered wastes, they have assumed to be wastes in the reference cycle. In this case, their relative contribution is significant for fuel cycles using enriched uranium. The totals for waste management and disposal are of the same order of magnitude as the collective dose commitments from occupational and public exposures arising from the operation of the nuclear fuel cycle installations. The incomplete collective dose commitments from waste management and disposal assessed by integrating the collective dose rate over a fixed period of time (usually selected as 500 years), at time when the integral is maximum, are also comparable with the corresponding quantity arising from the operation of the fuel cycle installations. The maximum per caput doses predicted for the far future are small, usually a small fraction of the relevant dose limits. The maximun future doses in the critical groups in the vicinity of the repositories will be very low, of about a few percents of that experienced from the exposure to natural radiation sources. (M.E.L.) [es

  10. Machine Learning in Radiology: Applications Beyond Image Interpretation.

    Science.gov (United States)

    Lakhani, Paras; Prater, Adam B; Hutson, R Kent; Andriole, Kathy P; Dreyer, Keith J; Morey, Jose; Prevedello, Luciano M; Clark, Toshi J; Geis, J Raymond; Itri, Jason N; Hawkins, C Matthew

    2018-02-01

    Much attention has been given to machine learning and its perceived impact in radiology, particularly in light of recent success with image classification in international competitions. However, machine learning is likely to impact radiology outside of image interpretation long before a fully functional "machine radiologist" is implemented in practice. Here, we describe an overview of machine learning, its application to radiology and other domains, and many cases of use that do not involve image interpretation. We hope that better understanding of these potential applications will help radiology practices prepare for the future and realize performance improvement and efficiency gains. Copyright © 2017 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  11. The significance of reduced respiratory chain enzyme activities: clinical, biochemical and radiological associations.

    Science.gov (United States)

    Mordekar, S R; Guthrie, P; Bonham, J R; Olpin, S E; Hargreaves, I; Baxter, P S

    2006-03-01

    Mitochondrial diseases are an important group of neurometabolic disorders in children with varied clinical presentations and diagnosis that can be difficult to confirm. To report the significance of reduced respiratory chain enzyme (RCE) activity in muscle biopsy samples from children. Retrospective odds ratio was used to compare clinical and biochemical features, DNA studies, neuroimaging, and muscle biopsies in 18 children with and 48 without reduced RCE activity. Children with reduced RCE activity were significantly more likely to have consanguineous parents, to present with acute encephalopathy and lactic acidaemia and/or within the first year of life; to have an axonal neuropathy, CSF lactate >4 mmol/l; and/or to have signal change in the basal ganglia. There were positive associations with a maternal family history of possible mitochondrial cytopathy; a presentation with failure to thrive and lactic acidaemia, ragged red fibres, reduced fibroblast fatty acid oxidation and with an abnormal allopurinol loading test. There was no association with ophthalmic abnormalities, deafness, epilepsy or myopathy. The association of these clinical, biochemical and radiological features with reduced RCE activity suggests a possible causative link.

  12. Environmental characterization and radiological impacts of non-nuclear industries on the red sea coast

    International Nuclear Information System (INIS)

    Mamoney, M. H. El; Khater, Ashraf E. M.

    2002-01-01

    The Red Sea is a deep semi-enclosed and narrow basin connected to the Indian Ocean by a narrow sill in the south and to the Suez Canal in the north. Oil industries in the Gulf of Suez, phosphate ore mining activities in Safaja- Quseir region and intensified navigation activities are non-nuclear land base pollution sources that could have a serious radiological impacts on the marine environment and the coastal ecosystems of the Red Sea. It is a need and an essential to draw up the radiological base-line data, which is not exist yet and to investigate the radio-ecological impact of non- nuclear industries to protect the coastal environment of the Red Sea. Natural and man- made radionuclides have been measured in shore sediment samples collected from the Egyptian coast of the Red Sea. The specific activities of 226 Ra ( 238 U)series, 232 Th series, 40 K, 137 Cs and 210 Pb (Bq/kg dry weight) were measured using gamma ray spectrometry based on hyper pure germanium detectors. The specific activities of 210 Po ( 210 Pb) and uranium isotopes ( 238 U, 235 U and 234 U), (Bq/kg dry weight) were measured using alpha spectrometry based on surface barrier (PIPS) detectors after radiochemical separation. The absorbed radiation dose rates in air (nGy/h) due to natural radionuclides in shore sediment and radium equivalent activity (Bq/kg) were calculated. The specific activity ratios of 228 Ra/ 226 Ra, 210 Pb/ 226 Ra, 226 Ra/ 238 U and 234 U/ 238 U were calculated for evaluation of geo-chemical behaviour of these radionuclides. These results were represented and discussed. The results gave an indication of the possible radiological impacts of oil industries in the northern region and phosphate mining activities in the Safaja-Quseir region

  13. Research and development in radiological protection; Investigacion y desarrollo en proteccion radiologica

    Energy Technology Data Exchange (ETDEWEB)

    Butragueno, J. L.; Villota, C.; Gutierrez, C.; Rodriguez, A.

    2004-07-01

    The objective of Radiological Protection is to gurantee that neither people, be they workers or members of the public, or the environment are exposed to radiological risks considered by society to be unacceptable. Among the various resources available to meet this objective is Research and Development (R and D), which is carried out in three areas: I. Radiological protection of persons: (a) knowledge of the biological effects of radiations, in order to determine the relationship that exists between radiation exposure dose and its effects on health; (b) the development of new personal dosimetry techniques in order to adapt to new situations, instrumental techniques and information managmenet technologies allowing for better assessment of exposure dose; and (c) development of the principle of radiological protection optimisation (ALARA), which has been set up internationally as the fundamental principle on which radiological protection interventions are based. II. Assessment of environmental radiological impact, the objective of which is to assess the nature and magnitude of situations of exposure to ionising radiations as a result of the controlled or uncontrolled release of radioactive material to the environment, and III.Reduction of the radiological impact of radioactive wastes, the objective of which is to develop radioactive material and waste management techniques suitable for each situation, in order to reduce the risks assocaited with their definitive managmenet or thier release to the environment. Briefly desribed below are the strategic lines of R and D of the CSN, the Electricity Industry, Ciemat and Enresa in the aforementioned areas. (Author)

  14. Radiological Impact Assessment in Disposal of Treated Sludge

    International Nuclear Information System (INIS)

    Khairuddin Mohamad Kontol; Ismail Sulaiman; Faizal Azrin Abdul Razalim

    2015-01-01

    Sludge and scales produced during oil and gas production contain enhanced naturally occurring radioactive material (NORM). Sludge and scales are under the jurisdiction of Department of Environment (DOE) and also Atomic Energy Licensing Board (AELB). AELB has issued a guideline regarding the disposal of sludge and scales as in its guideline (LEM/TEK/30 SEM.2, 1996). In this guideline, Radiological Impact Assessment (RIA) should be carried out on all proposed disposals and has to demonstrate that no member of public will be exposed to more than 1 mSv/y. This paper presented RIA analysis using RESRAD computer code for the disposal of treated sludge. RESRAD (RESidual RADioactive) developed by Argonne National Laboratory is to estimate radiation doses and risks from residual radioactive materials. The dose received by the member of public is found to be well below the stipulated limit. (author)

  15. Emergency radiological monitoring and analysis: Federal Radiological Monitoring and Assessment Center

    International Nuclear Information System (INIS)

    Thome, D.J.

    1995-01-01

    The US Federal Radiological Emergency Response Plan (FRERP) provides the framework for integrating the various Federal agencies responding to a major radiological emergency. The FRERP authorizes the creation of the Federal Radiological Monitoring and Assessment Center (FRMAC), which is established to coordinate all Federal agencies involved in the monitoring and assessment of the off-site radiological conditions in support of the impacted State(s) and the Lead Federal Agency (LFA). Within the FRMAC, the Monitoring and Analysis Division (M ampersand A) is responsible for coordinating all FRMAC assets involved in conducting a comprehensive program of environmental monitoring, sampling, radioanalysis, and quality assurance. To assure consistency, completeness, and the quality of the data produced, a methodology and procedures manual is being developed. This paper discusses the structure, assets, and operations of the FRMAC M ampersand A and the content and preparation of the manual

  16. Calculations of the radiological impact of disposal of unit activity of selected radionuclides for use in waste management system studies

    International Nuclear Information System (INIS)

    Smith, G.M.

    1985-03-01

    The purpose of the work described is to provide estimates of the radiological impact following disposal of unit activity via each of several options, including shallow burial, engineered trench disposal, disposal in a geologic repository and disposal on the deep ocean bed. Results are presented for a range of important representative radionuclides. No single option is clearly the best from the radiological point of view. However, in conjunction with waste inventory data the results may be used to provide a preliminary view of the relative radiological merits of the various disposal options. (author)

  17. "Flipping" the introductory clerkship in radiology: impact on medical student performance and perceptions.

    Science.gov (United States)

    Belfi, Lily M; Bartolotta, Roger J; Giambrone, Ashley E; Davi, Caryn; Min, Robert J

    2015-06-01

    Among methods of "blended learning" (ie, combining online modules with in-class instruction), the "flipped classroom" involves student preclass review of material while reserving class time for interactive knowledge application. We integrated blended learning methodology in a "flipped" introductory clerkship in radiology, and assessed the impact of this approach on the student educational experience (performance and perception). In preparation for the "flipped clerkship," radiology faculty and residents created e-learning modules that were uploaded to an open-source website. The clerkship's 101 rising third-year medical students were exposed to different teaching methods during the course, such as blended learning, traditional lecture learning, and independent learning. Students completed precourse and postcourse knowledge assessments and surveys. Student knowledge improved overall as a result of taking the course. Blended learning achieved greater pretest to post-test improvement of high statistical significance (P value, .0060) compared to lecture learning alone. Blended learning also achieved greater pretest to post-test improvement of borderline statistical significance (P value, .0855) in comparison to independent learning alone. The difference in effectiveness of independent learning versus lecture learning was not statistically significant (P value, .2730). Student perceptions of the online modules used in blended learning portions of the course were very positive. They specifically enjoyed the self-paced interactivity and the ability to return to the modules in the future. Blended learning can be successfully applied to the introductory clerkship in radiology. This teaching method offers educators an innovative and efficient approach to medical student education in radiology. Copyright © 2015 AUR. Published by Elsevier Inc. All rights reserved.

  18. Preliminary assessment of radiological doses in alternative waste management systems without an MRS facility

    International Nuclear Information System (INIS)

    Schneider, K.J.; Pelto, P.J.; Daling, P.M.; Lavender, J.C.; Fecht, B.A.

    1986-06-01

    This report presents generic analyses of radiological dose impacts of nine hypothetical changes in the operation of a waste management system without a monitored retrievable storage (MRS) facility. The waste management activities examined in this study include those for handling commercial spent fuel at nuclear power reactors and at the surface facilities of a deep geologic repository, and the transportation of spent fuel by rail and truck between the reactors and the repository. In the reference study system, the radiological doses to the public and to the occupational workers are low, about 170 person-rem/1000 metric ton of uranium (MTU) handled with 70% of the fuel transported by rail and 30% by truck. The radiological doses to the public are almost entirely from transportation, whereas the doses to the occupational workers are highest at the reactors and the repository. Operating alternatives examined included using larger transportation casks, marshaling rail cars into multicar dedicated trains, consolidating spent fuel at the reactors, and wet or dry transfer options of spent fuel from dry storage casks. The largest contribution to radiological doses per unit of spent fuel for both the public and occupational workers would result from use of truck transportation casks, which are smaller than rail casks. Thus, reducing the number of shipments by increasing cask sizes and capacities (which also would reduce the number of casks to be handled at the terminals) would reduce the radiological doses in all cases. Consolidating spent fuel at the reactors would reduce the radiological doses to the public but would increase the doses to the occupational workers at the reactors

  19. Multidisciplinary team meetings and their impact on workflow in radiology and pathology departments

    Directory of Open Access Journals (Sweden)

    O'Briain D Sean

    2007-06-01

    Full Text Available Abstract Background The development of multidisciplinary team meetings (MDTMs for radiology and pathology is a burgeoning area that increasingly impacts on work processes in both of these departments. The aim of this study was to examine work processes and quantify the time demands on radiologists and pathologists associated with MDTM practices at a large teaching hospital. The observations reported in this paper reflect a general trend affecting hospitals and our conclusions will have relevance for others implementing clinical practice guidelines. Methods For one month, all work related to clinical meetings between pathology and radiology with clinical staff was documented and later analysed. Results The number of meetings to which pathology and radiology contribute at a large university teaching hospital, ranges from two to eight per day, excluding grand rounds, and amounts to approximately 50 meetings per month for each department. For one month, over 300 h were spent by pathologists and radiologists on 81 meetings, where almost 1000 patients were discussed. For each meeting hour, there were, on average, 2.4 pathology hours and 2 radiology hours spent in preparation. Two to three meetings per week are conducted over a teleconferencing link. Average meeting time is 1 h. Preparation time per meeting ranges from 0.3 to 6 h for pathology, and 0.5 to 4 for radiology. The review process in preparation for meetings improves internal quality standards. Materials produced externally (for example imaging can amount to almost 50% of the material to be reviewed on a single patient. The number of meetings per month has increased by 50% over the past two years. Further increase is expected in both the numbers and duration of meetings when scheduling issues are resolved. A changing trend in the management of referred patients with the development of MDTMs and the introduction of teleconferencing was noted. Conclusion Difficulties are being experienced by

  20. An analysis of radiological research publications in high impact general medical journals between 1996 and 2010

    International Nuclear Information System (INIS)

    Ku, You Jin; Yoon, Dae Young; Yun, Eun Joo; Baek, Sora; Lim, Kyoung Ja; Seo, Young Lan; Choi, Chul Soon; Bae, Sang Hoon

    2013-01-01

    Highlights: ► Radiologists published only 0.2% of articles in five general medical journals. ► Most original articles from radiologists were funded and were prospective studies. ► Radiology researchers from only 11 countries published at least one original article. -- Abstract: Objective: To evaluate scientific papers published by radiologists in high impact general medical journals between 1996 and 2010. Methods: A MEDLINE search was performed in five high impact general medical journals (AIM, BMJ, JAMA, Lancet, and NEJM) for all articles of which a radiologist was the first author between 1996 and 2010. The following information was abstracted from the original articles: radiological subspecialty, imaging technique used, type of research, sample size, study design, statistical analysis, study outcome, declared funding, number of authors, collaboration, and country of the first author. Results: Of 216 (0.19%) articles were published by radiologists in five general medical journals between 1996 and 2010, 83 were original articles. Fifteen (18.1%) original articles were concerned with the field of vascular/interventional radiology, 24 (28.9%) used combined imaging techniques, 76 (91.6%) were clinical research, 63 (75.9%) had a sample size of >50, 65 (78.3%) were prospective, 78 (94.0%) performed statistical analysis, 83 (100%) showed positive study outcomes, 57 (68.7%) were funded, 49 (59.0%) had from four to seven authors, and 79 (95.2%) were collaborative studies. Conclusions: A very small number (0.19%) in five high impact general medical journals was published by radiologists between 1996 and 2010

  1. An experimental investigation on reduced radiological penumbra for intermediate energy x-rays: Implications for small field radiosurgery

    Science.gov (United States)

    Keller, Brian Michael

    Current day external beam radiation therapy typically uses x-ray energies in the megavoltage (6--18 MV) or in the superficial/orthovoltage (80--350 kVp) energy ranges. It has been found that intermediate energy x-rays (those greater than orthovoltage but sub-megavoltage) may offer an advantage in the field of high precision radiation therapy such as in radiosurgery. This advantage is a reduction in the radiological penumbra associated with small (less than about 3 cm) radiation dose fields. A consequence of reduced radiological penumbra is a more homogenous, conformal dose distribution in the patient with dose escalation and organ sparing made more feasible. The objectives of this thesis were as follows: to produce and to characterize an intermediate energy x-ray beam, to establish a method of accurate penumbra measurement at the micron level for millimeter size fields, to measure the radiological penumbra of single small intermediate energy x-ray fields, and to show the clinical consequences of a multiple beam irradiation in a stereotactic head phantom. A maximum photon energy of 1.2 +/- 0.1 MeV was determined for the intermediate energy x-ray spectrum at the expense of a low dose rate. A digital microscope with a computer controlled translation stage was investigated for its ability to resolve steep dose gradients in Gafchromic EBT film for field sizes as small as 1 mm and for photon energies as low as 100 kVp. The microscope-film system resolved gradients to within about 30 mum, limited by the inherent spatial resolution of the film, the noise of the system, and the uncertainties of measurement. Penumbra widths were compared for 1.2 MV versus 6 MV for identical irradiation conditions. In some instances, there was a five-fold reduction in the radiological penumbra of single 1.2 MV x-ray beams. A multiple beam arc irradiation demonstrated that the advantages seen with single beams carry over to multiple beams. The benefits of reduced radiological penumbra for

  2. Comparative Study on Radiological Impact Due To Direct Exposure to a Radiological Dispersal Device Using A Sealed Radiation Source

    International Nuclear Information System (INIS)

    Margeanu, C.A.

    2011-01-01

    Nowadays, one of the most serious terrorist threats implies radiological dispersal devices (RDDs), the so-called dirty bombs, that combine a conventional explosive surrounded by an inflammatory material (like thermit) with radioactive material. The paper objective is to evaluate the radiological impact due to direct exposure to a RDD using a sealed radiation source (used for medical and industrial applications) as radioactive material. The simulations were performed for 60Co, 137Cs and 192Ir radiation sources. In order to model the contamination potential level and radiation exposure due to radioactive material spreading from RDD, Lawrence Livermore National Laboratory's HOTSPOT 2.07 computer code was used. The worst case scenario has been considered, calculations being performed for two radioactive material dispersion models, namely General radioactive Plume and General Explosion. Following parameters evolution with distance from the radiation source was investigated: total effective dose equivalent, time-integrated air concentration, ground surface deposition and ground shine dose rates. Comparisons between considered radiation sources and radioactive material dispersion models have been performed. The most drastic effects on population and the environment characterize 60Co sealed radiation source use in RDD.

  3. Support for biomedical research and its impact on radiology.

    Science.gov (United States)

    Bragg, D G; Hendee, W R

    1994-12-01

    Research in medical imaging has experienced substantial growth during the past decade. Still, research is a small fraction of the budget of the typical academic radiology program. Few radiology faculty participate in hypothesis-driven research projects. Funding of research will be more difficult to secure in the future, since clinical subsidies will diminish or disappear, support from industry is decreasing, and funds from private foundations and philanthropists are not likely to increase. Support from the NIH will probably remain about level in constant dollars. In response to these constraints, radiology will have to be both more creative and more opportunistic to tap the limited remaining resources of research support. An excellent compilation of some major resources was recently published by Williams and Holden (9). Efforts of the Conjoint Committee will continue to be critical for continuing support of the LDRR, encouraging the allocation of intramural and extramural resources of the NCI to medical imaging, guiding the development of the American Academy of Radiologic Research, providing research training opportunities for physicians and scientists in radiology, and leading the research effort in medical imaging in general (10). Within individual institutions and departments, imaging research must continue to be acknowledged as a priority despite increasing pressures to generate clinical revenue. Enhanced efforts are warranted to nurture the research interests of younger faculty and selected residents and fellows, including pairing them with research mentors and providing them with opportunities to develop skills in areas such as research design, statistical analysis, and evaluative techniques. The long-term well-being of radiology and its important contributions to patient care are dependent on its continued investment in research and development.

  4. Generic environmental impact statement in support of rulemaking on radiological criteria for license termination of NRC-licensed nuclear facilities. Final report, appendices A and B

    International Nuclear Information System (INIS)

    1997-07-01

    The action being considered in this Final Generic Environmental Impact Statement (GEIS) is an amendment to the Nuclear Regulatory Commission''s (NRC) regulations in 10 CFR Part 20 to include radiological criteria for decommissioning of lands and structures at nuclear facilities. Under the National Environmental Policy Act (NEPA), all Federal agencies must consider the effect of their actions on the environment. To fulfill NRC''s responsibilities under NEPA, the Commission is preparing this GEIS which analyzes alternative courses of action and the costs and impacts associated with those alternatives. In preparing the final GEIS, the following approach was taken: (1) a listing was developed of regulatory alternatives for establishing radiological criteria for decommissioning; (2) for each alternative, a detailed analysis and comparison of incremental impacts, both radiological and nonradiological, to workers, members of the public, and the environment, and costs were performed; and (3) based on the analysis of impacts and costs, conclusions on radiological criteria for decommissioning were provided. Contained in the GEIS are results and conclusions related to achieving, as an objective of decommissioning ALARA, reduction to preexisting background, the radiological criterion for unrestricted use, decommissioning ALARA analysis for soils and structures containing contamination, restricted use and alternative analysis for special site-specific situations and groundwater cleanup. In its analyses, the final GEIS includes consideration of comments made on the draft GEIS during the public comment period

  5. Federal support of radiological research

    International Nuclear Information System (INIS)

    Hendee, W.R.

    1981-01-01

    Pervading the plans and objective outlined herein for continued and enhanced federal support of research in radiology is a challenge of unparalleled magnitude, for the economic foundation on which this support is based has rarely been more precarious. The new administration in Washington may well be the most fiscally constrained in half a century, and its stated interest in reducing federal expenditures could have disastrous consequences for the scientific research effort in this country, including that in radiology and the radiological sciences. The circumvention of these consequences may well require the dedicated effort of the entire scientific community over the next few months and years, including that part representing radiology and the radiological sciences

  6. Socio-economic and other non-radiological impacts of the near surface disposal of radioactive waste

    International Nuclear Information System (INIS)

    2002-09-01

    The objective of this report is to introduce, in a generic sense, the elements that could comprise a socio-economic and non-radiological environmental impact assessment. The various social, economic and environmental impacts that could be associated with surface and near surface disposal are discussed through factors that could apply at the local, regional or national level. Impact management is also discussed. The report also introduces concepts to help Member States develop their own approaches to undertaking impact assessment and management. The report is intended to complement IAEA documents on the technology and safety aspects of the near surface disposal of radioactive waste. The scope of this report includes a discussion of a range of social, economic and nonradiological environmental impacts relevant to surface and near surface disposal and illustrations of some impact management measures

  7. The radiological impact of past and present practices of the mineral sands industry in Queensland

    International Nuclear Information System (INIS)

    Alexander, E.G.; Stewart, N.D.; Wallace, B.J.

    1993-01-01

    It is shown that the introduction of uniform Australian national Codes of Practice for radiation protection in the mining and milling of radioactive ores in the early 1980's has led to the mining and health regulatory authorities implementing the provisions of the Codes. Deficiencies involving dust and external gamma radiation levels in the mineral sands industry have led to various administrative and engineering controls being introduced to reduce the levels of radiation doses to employees well below 20 mSv/y limit. There are guidelines for screening the radioactivity of tailings released into the environment and some products for industrial use. Future activities by the regulatory authorities and industry will involve an optimisation of radiation protection, ongoing remedial programs, register of data about contaminated lands and assessments of the environmental, occupational and the public radiological impacts from downstream processing of mineral sands. The latter involves synthetic rutile, zircon flour, rare earth and refractory technologies. 7 refs., 1 tab., 1 fig

  8. Generic environmental impact statement in support of rulemaking on radiological criteria for decommissioning of NRC-licensed nuclear facilities. Appendices; Draft report for comment -- Volume 2

    International Nuclear Information System (INIS)

    1994-08-01

    The action being considered in this draft Generic Environmental Impact Statement (GEIS) is an amendment to the Nuclear Regulatory Commission's (NRC) regulations in 10 CFR Part 20 to include radiological criteria for decommissioning of lands and structures at nuclear facilities. Under the National Environmental Policy Act (NEPA), all Federal agencies must consider the effect of their actions on the environment. To fulfill NRC's responsibilities under NEPA, the Commission is preparing this GEIS which analyzes alternative courses of action and the costs and impacts associated with those alternatives. In preparing the GEIS, the following approach was taken: (1) a listing was developed of regulatory alternatives for establishing radiological criteria for decommissioning; (2) for each alternative, a detailed analysis and comparison of incremental impacts, both radiological and nonradiological, to workers, members of the public, and the environment, and costs, were performed; and (3) based on the analysis of impacts and costs, preliminary recommendations were provided. Contained in the GEIS are recommendations related to the definition of decommissioning, the scope of rulemaking, the radiological criteria, restrictions on use, citizen participation, use of the GEIS in site-specific cases, and minimization of contamination

  9. Focused process improvement events: sustainability of impact on process and performance in an academic radiology department.

    Science.gov (United States)

    Rosenkrantz, Andrew B; Lawson, Kirk; Ally, Rosina; Chen, David; Donno, Frank; Rittberg, Steven; Rodriguez, Joan; Recht, Michael P

    2015-01-01

    To evaluate sustainability of impact of rapid, focused process improvement (PI) events on process and performance within an academic radiology department. Our department conducted PI during 2011 and 2012 in CT, MRI, ultrasound, breast imaging, and research billing. PI entailed participation by all stakeholders, facilitation by the department chair, collection of baseline data, meetings during several weeks, definition of performance metrics, creation of an improvement plan, and prompt implementation. We explore common themes among PI events regarding initial impact and durability of changes. We also assess performance in each area pre-PI, immediately post-PI, and at the time of the current study. All PI events achieved an immediate improvement in performance metrics, often entailing both examination volumes and on-time performance. IT-based solutions, process standardization, and redefinition of staff responsibilities were often central in these changes, and participants consistently expressed improved internal leadership and problem-solving ability. Major environmental changes commonly occurred after PI, including a natural disaster with equipment loss, a change in location or services offered, and new enterprise-wide electronic medical record system incorporating new billing and radiology informatics systems, requiring flexibility in the PI implementation plan. Only one PI team conducted regular post-PI follow-up meetings. Sustained improvement was frequently, but not universally, observed: in the long-term following initial PI, measures of examination volume showed continued progressive improvements, whereas measures of operational efficiency remained stable or occasionally declined. Focused PI is generally effective in achieving performance improvement, although a changing environment influences the sustainability of impact. Thus, continued process evaluation and ongoing workflow modifications are warranted. Copyright © 2015 American College of Radiology

  10. Consequences of radiological emergencies at Goiania and Mayapuri

    International Nuclear Information System (INIS)

    Sharma, Ranjit; Pradeepkumar, K.S.; Singh, Rajvir

    2012-01-01

    Radiological accidents due to orphan sources can lead to emergencies in the public domain, as reported worldwide. Inadequate regulatory control, lack of accountability and improper disposal of radioactive materials in scrap have resulted in radiological emergencies. Apart from few fatalities, they lead to environmental contamination, economic loss and social and psychological impact on the society. The 137 Cs and 60 Co sources of strength TBq to PBq activity level may pose high radiation exposure risk if shielding integrity is affected in any accident. There had been few radiological accidents reported world over which resulted in radiation injuries, environmental contamination and out of proportion panic in the society. The response actions for both these radiological emergencies included search, recovery of sources, decontamination and waste removal for reducing the radiation/contamination levels at the affected site. In both cases, encapsulated sources were damaged by the persons unknowingly. Response operations were carried out for longer period at Goiania compared to Mayapuri because of large scale contamination. 60 Co source being metallic in nature, even after the breaking of sources at Mayapuri the spread of contamination was confined to a small area. In Goiania, the granules of Cesium Chloride were distributed to many people because of its glowing nature in dark which caused spread of contamination to a large area and the accident was detected early as more persons reported with radiation injuries. The detection of Mayapuri accident was delayed as affected personnel reported to the hospital after three weeks of exposure to radiation. The lack of expertise in identifying radiation injuries by medical professionals contributed to further delay in reporting and detection of this emergency. The fatalities in both accidents resulted from acute radiation exposures and delay in getting medical support. The experience gained at radiological emergencies of Goiania

  11. Multidisciplinary team meetings and their impact on workflow in radiology and pathology departments.

    LENUS (Irish Health Repository)

    Kane, Bridget

    2007-01-01

    The development of multidisciplinary team meetings (MDTMs) for radiology and pathology is a burgeoning area that increasingly impacts on work processes in both of these departments. The aim of this study was to examine work processes and quantify the time demands on radiologists and pathologists associated with MDTM practices at a large teaching hospital. The observations reported in this paper reflect a general trend affecting hospitals and our conclusions will have relevance for others implementing clinical practice guidelines.

  12. Cognitive and system factors contributing to diagnostic errors in radiology.

    Science.gov (United States)

    Lee, Cindy S; Nagy, Paul G; Weaver, Sallie J; Newman-Toker, David E

    2013-09-01

    In this article, we describe some of the cognitive and system-based sources of detection and interpretation errors in diagnostic radiology and discuss potential approaches to help reduce misdiagnoses. Every radiologist worries about missing a diagnosis or giving a false-positive reading. The retrospective error rate among radiologic examinations is approximately 30%, with real-time errors in daily radiology practice averaging 3-5%. Nearly 75% of all medical malpractice claims against radiologists are related to diagnostic errors. As medical reimbursement trends downward, radiologists attempt to compensate by undertaking additional responsibilities to increase productivity. The increased workload, rising quality expectations, cognitive biases, and poor system factors all contribute to diagnostic errors in radiology. Diagnostic errors are underrecognized and underappreciated in radiology practice. This is due to the inability to obtain reliable national estimates of the impact, the difficulty in evaluating effectiveness of potential interventions, and the poor response to systemwide solutions. Most of our clinical work is executed through type 1 processes to minimize cost, anxiety, and delay; however, type 1 processes are also vulnerable to errors. Instead of trying to completely eliminate cognitive shortcuts that serve us well most of the time, becoming aware of common biases and using metacognitive strategies to mitigate the effects have the potential to create sustainable improvement in diagnostic errors.

  13. Radiological Impacts and Regulation of Rare Earth Elements in Non-Nuclear Energy Production

    Directory of Open Access Journals (Sweden)

    Timothy Ault

    2015-03-01

    Full Text Available Energy industries account for a significant portion of total rare earth usage, both in the US and worldwide. Rare earth minerals are frequently collocated with naturally occurring radioactive material, imparting an occupational radiological dose during recovery. This paper explores the extent to which rare earths are used by various non-nuclear energy industries and estimates the radiological dose which can be attributed to these industries on absolute and normalized scales. It was determined that typical rare earth mining results in an occupational collective dose of approximately 0.0061 person-mSv/t rare earth elements, amounting to a total of 330 person-mSv/year across all non-nuclear energy industries (about 60% of the annual collective dose from one pressurized water reactor operated in the US, although for rare earth mining the impact is spread out over many more workers. About half of the collective dose from non-nuclear energy production results from use of fuel cracking catalysts for oil refining, although given the extent of the oil industry, it is a small dose when normalized to the energy equivalent of the oil that is used annually. Another factor in energy industries’ reliance on rare earths is the complicated state of the regulation of naturally occurring radiological materials; correspondingly, this paper also explores regulatory and management implications.

  14. Controlling the radiological impact in the nuclear fuel cycle: a cost/benefit analysis

    International Nuclear Information System (INIS)

    Blanco, R.E.

    1976-01-01

    Methods that are used to control the radiological impact of the nuclear fuel cycle are discussed. This control is exercised through the application of a series of Federal laws and regulations that are used as the basis for licensing nuclear facilities. These licenses contain technical specifications which define the limits for the release of radioactive materials. The control is exercised more directly in a technical sense by the use of radwaste treatment equipment at the nuclear facilities to limit the release of radioactive materials. The first part of this paper contains a summary of the principal Federal laws and regulations that apply to nuclear fuel cycle facilities and a description of how they are applied in licensing procedures. A detailed discussion is presented of the amounts of radioactive materials that may be released from licensed facilities, and the radiological doses that individuals and populations surrounding these facilities would receive from these releases. These doses are then compared with the radiological doses received from natural background radiation to put them in perspective. Cost/benefit engineering surveys which are being made to determine the cost (in dollars) and the effectiveness of radwaste systems for decreasing the release of radioactive materials from model fuel cycle facilities, and to determine the benefits in terms of reduction in dose commitment to individuals and populations in surrounding areas are described

  15. Action research regarding the optimisation of radiological protection for nurses during vascular interventional radiology

    International Nuclear Information System (INIS)

    Mori, Hiroshige

    2015-01-01

    The optimisation and decision-making processes for radiological protection have been broadened by the introduction of re-examination or feedback after introducing protective measures. In this study, action research was used to reduce the occupational exposure of vascular interventional radiology (IR) nurses. Four radiological protection improvement measures were continuously performed in cooperation with the researchers, nurses and stakeholders, and the nurses’ annual effective doses were compared before and after the improvements. First, the dosimetry equipment was changed from one electronic personal dosimeter (EPD) to two silver-activated phosphate glass dosimeters (PGDs). Second, the nurses were educated regarding maintaining a safe distance from the sources of scattered and leakage radiation. Third, portable radiation shielding screens were placed in the IR rooms. Fourth, the x-ray units’ pulse rates were reduced by half. On changing the dosimetry method, the two PGDs recorded a 4.4 fold greater dose than the single EPD. Educating nurses regarding radiological protection and reducing the pulse rates by half decreased their effective doses to one-third and two-fifths of the baseline dose, respectively. No significant difference in their doses was detected after the placement of the shielding screens. Therefore, the action research effectively decreased the occupational doses of the vascular IR nurses. (practical matter)

  16. Action research regarding the optimisation of radiological protection for nurses during vascular interventional radiology.

    Science.gov (United States)

    Mori, Hiroshige

    2015-06-01

    The optimisation and decision-making processes for radiological protection have been broadened by the introduction of re-examination or feedback after introducing protective measures. In this study, action research was used to reduce the occupational exposure of vascular interventional radiology (IR) nurses. Four radiological protection improvement measures were continuously performed in cooperation with the researchers, nurses and stakeholders, and the nurses' annual effective doses were compared before and after the improvements. First, the dosimetry equipment was changed from one electronic personal dosimeter (EPD) to two silver-activated phosphate glass dosimeters (PGDs). Second, the nurses were educated regarding maintaining a safe distance from the sources of scattered and leakage radiation. Third, portable radiation shielding screens were placed in the IR rooms. Fourth, the x-ray units' pulse rates were reduced by half. On changing the dosimetry method, the two PGDs recorded a 4.4 fold greater dose than the single EPD. Educating nurses regarding radiological protection and reducing the pulse rates by half decreased their effective doses to one-third and two-fifths of the baseline dose, respectively. No significant difference in their doses was detected after the placement of the shielding screens. Therefore, the action research effectively decreased the occupational doses of the vascular IR nurses.

  17. Radiology education: a glimpse into the future

    Energy Technology Data Exchange (ETDEWEB)

    Scarsbrook, A.F. [Department of Radiology, John Radcliffe Hospital, Headley Way, Headington, Oxford (United Kingdom)]. E-mail: andyscarsbrook1@aol.com; Graham, R.N.J. [Department of Radiology, John Radcliffe Hospital, Headley Way, Headington, Oxford (United Kingdom); Perriss, R.W. [Department of Radiology, John Radcliffe Hospital, Headley Way, Headington, Oxford (United Kingdom)

    2006-08-15

    The digital revolution in radiology continues to advance rapidly. There are a number of interesting developments within radiology informatics which may have a significant impact on education and training of radiologists in the near future. These include extended functionality of handheld computers, web-based skill and knowledge assessment, standardization of radiological procedural training using simulated or virtual patients, worldwide videoconferencing via high-quality health networks such as Internet2 and global collaboration of radiological educational resources via comprehensive, multi-national databases such as the medical imaging resource centre initiative of the Radiological Society of North America. This article will explore the role of e-learning in radiology, highlight a number of useful web-based applications in this area, and explain how the current and future technological advances might best be incorporated into radiological training.

  18. Radiology education: a glimpse into the future

    International Nuclear Information System (INIS)

    Scarsbrook, A.F.; Graham, R.N.J.; Perriss, R.W.

    2006-01-01

    The digital revolution in radiology continues to advance rapidly. There are a number of interesting developments within radiology informatics which may have a significant impact on education and training of radiologists in the near future. These include extended functionality of handheld computers, web-based skill and knowledge assessment, standardization of radiological procedural training using simulated or virtual patients, worldwide videoconferencing via high-quality health networks such as Internet2 and global collaboration of radiological educational resources via comprehensive, multi-national databases such as the medical imaging resource centre initiative of the Radiological Society of North America. This article will explore the role of e-learning in radiology, highlight a number of useful web-based applications in this area, and explain how the current and future technological advances might best be incorporated into radiological training

  19. Radiological protection of patients in diagnostic and interventional radiology, nuclear medicine and radiotherapy. Contributed papers

    International Nuclear Information System (INIS)

    2001-01-01

    An International Conference on the Radiological Protection of Patients in Diagnostic and Interventional Radiology, Nuclear Medicine and Radiotherapy organized by the International Atomic Energy Agency and co-sponsored by the European Commission, the Pan American Health Organization and the World Health Organization was held in Malaga, Spain, from 26 to 30 March 2001. The Government of Spain hosted this Conference through the Ministerio de Sanidad y Consumo, the Consejo de Seguridad Nuclear, the Junta de Andalucia, the Universidad de Malaga and the Grupo de Investigacion en Proteccion Radiologica de la Universidad de Malaga (PRUMA). The Conference was organized in co-operation with the United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR), the International Commission on Radiological Protection (ICRP) and the following professional societies: International Organization of Medical Physicists (IOMP), International Radiation Protection Association (IRPA), International Society of Radiation Oncology (ISRO), International Society of Radiology (ISR), International Society of Radiographers and Radiological Technologists (ISRRT) and World Federation of Nuclear Medicine and Biology (WFNMB). This publication contains contributed papers submitted to the Conference Programme Committee. The papers are in one of the two working languages of this Conference, English and Spanish. The topics covered by the Conference are as follows: Radiological protection of patients in general diagnostic radiology (radiography), Radiological protection of patients in general diagnostic radiology (fluoroscopy), Radiological protection issues in specific uses of diagnostic radiology, such as mammography and computed tomography (with special consideration of the impact of digital techniques), Radiological protection in interventional radiology, including fluoroscopy not carried out by radiologists, Radiological protection of patients in nuclear medicine, Developing and

  20. Radiological protection of patients in diagnostic and interventional radiology, nuclear medicine and radiotherapy. Contributed papers

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-03-01

    An International Conference on the Radiological Protection of Patients in Diagnostic and Interventional Radiology, Nuclear Medicine and Radiotherapy organized by the International Atomic Energy Agency and co-sponsored by the European Commission, the Pan American Health Organization and the World Health Organization was held in Malaga, Spain, from 26 to 30 March 2001. The Government of Spain hosted this Conference through the Ministerio de Sanidad y Consumo, the Consejo de Seguridad Nuclear, the Junta de Andalucia, the Universidad de Malaga and the Grupo de Investigacion en Proteccion Radiologica de la Universidad de Malaga (PRUMA). The Conference was organized in co-operation with the United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR), the International Commission on Radiological Protection (ICRP) and the following professional societies: International Organization of Medical Physicists (IOMP), International Radiation Protection Association (IRPA), International Society of Radiation Oncology (ISRO), International Society of Radiology (ISR), International Society of Radiographers and Radiological Technologists (ISRRT) and World Federation of Nuclear Medicine and Biology (WFNMB). This publication contains contributed papers submitted to the Conference Programme Committee. The papers are in one of the two working languages of this Conference, English and Spanish. The topics covered by the Conference are as follows: Radiological protection of patients in general diagnostic radiology (radiography), Radiological protection of patients in general diagnostic radiology (fluoroscopy), Radiological protection issues in specific uses of diagnostic radiology, such as mammography and computed tomography (with special consideration of the impact of digital techniques), Radiological protection in interventional radiology, including fluoroscopy not carried out by radiologists, Radiological protection of patients in nuclear medicine, Developing and

  1. Emergency radiological monitoring and analysis United States Federal Radiological Monitoring and Assessment Center

    International Nuclear Information System (INIS)

    Thome, D.J.

    1994-01-01

    The United States Federal Radiological Emergency Response Plan (FRERP) provides the framework for integrating the various Federal agencies responding to a major radiological emergency. Following a major radiological incident the FRERP authorizes the creation of the Federal Radiological Monitoring and Assessment Center (FRMAC). The FRMAC is established to coordinate all Federal agencies involved in the monitoring and assessment of the off-site radiological conditions in support of the impacted states and the Lead Federal Agency (LFA). Within the FRMAC, the Monitoring and Analysis Division is responsible for coordinating all FRMAC assets involved in conducting a comprehensive program of environmental monitoring, sampling, radioanalysis and quality assurance. This program includes: (1) Aerial Radiological Monitoring - Fixed Wing and Helicopter, (2) Field Monitoring and Sampling, (3) Radioanalysis - Mobile and Fixed Laboratories, (4) Radiation Detection Instrumentation - Calibration and Maintenance, (5) Environmental Dosimetry, and (6) An integrated program of Quality Assurance. To assure consistency, completeness and the quality of the data produced, a methodology and procedures handbook is being developed. This paper discusses the structure, assets and operations of FRMAC monitoring and analysis and the content and preparation of this handbook

  2. The radiological environment impact in China's nuclear industry over past 30 years

    International Nuclear Information System (INIS)

    Pan Ziqiang; Wang Zhipo; Chen Zhuzhou; Xie Jianlun

    1989-01-01

    This paper describes the methodology and main results of radiological environmental impacts of nuclear industry in China over the past 30 years. Generally speaking, the environmental impacts of Chinese nuclear industry are very small. The radiation doses to the critical group around the nuclear facilities are less than 5 mSv/a, of which 77.1 percent of the unit years are less than 0.25 mSv/a. The total annaul collective dose to the residents around nuclear facilities within 80 km is less than 1/10,000 of collective dose from natural radiation in the same areas. The collective dose from uranium mines and mills is much higher than that from other nuclear facilities, and is about 91.5% of the collective dose from the entire nuclear fuel cycle

  3. An assessment of the radiological impact of sea-dumping at the North East Atlantic dump site

    International Nuclear Information System (INIS)

    Delow, C.E.; Mobbs, S.F.; Hill, M.D.

    1985-04-01

    This report describes the models and methodology developed for the assessment of the radiological impact of disposal of low and intermediate level waste on the seabed. The development of the waste package model and the combined model of radionuclide dispersion and interactions with sediments in the world's ocean is outlined. This integrated set of models was used for the radiological assessment of sea dumping at the North-East Atlantic site, which formed part of the recent NEA review of the continued suitability of this site. The predicted radiation doses to man are presented, together with the results of the analysis of the sensitivity of the annual individual doses to critical groups to variations in model parameters. (author)

  4. Criteria and actions facing a radiological environmental contamination

    International Nuclear Information System (INIS)

    Gutierrez, Jose; Montero, Milagros

    2008-01-01

    An approach to improve the management of the radiological risk due to an environmental contamination is presented. The experience gained in emergency response has clearly demonstrated the importance to have an efficient emergency system including planning, procedures and operational internally consistent criteria. The lack of these components in the emergency system could lead to important radiological and non radiological consequences. The setting of internationally agreed criteria and guides is very important in the anticipated emergency response plan. The paper firstly reviews the approaches proposed by international recommendations and norms. From this review, a substantial coincidence on the basic principles is stated, in spite of small differences in its formulation. Also, a need for harmonization is endorsed. So, generic levels, in terms of imparted dose or avoided dose due to intervention, and, in some cases, derived levels, in terms of activity concentration, are proposed. Numerical values for emergency actions are also identified. The second part deals with the adaptation of the existing prediction and decision systems to the above radiological criteria. Relations among deposition, activity concentrations and annual doses for different scenarios, exposure pathways and age groups are established. Also, the sensibility of the radiological impact against different characteristics of the intervention scenarios is stated. This makes easy to assess the radiological significance of different contamination situations by comparison to the existing action generic levels. Furthermore, the radiological impact can be numerically incorporated in a decision system which includes non radiological aspects of the applicable intervention options. Agricultural, urban and mixed scenarios are presented and solved for a 137 Cs contamination. The results can be further used to develop a methodology guide for setting action generic levels in post-accidental interventions and

  5. Differential Motivations for Pursuing Diagnostic Radiology by Gender: Implications for Residency Recruitment.

    Science.gov (United States)

    Grimm, Lars J; Lowell, Dorothy A; Cater, Sarah W; Yoon, Sora C

    2017-10-01

    The purpose of this study is to determine how the motivations to pursue a career in radiology differ by gender. In addition, the influence of medical school radiology education will be assessed. Radiology applicants to our institution from the 2015-2016 interview season were offered an online survey in February 2016. Respondents scored the influence of 24 aspects of radiology on their decision to pursue radiology. Comparisons were made between male and female respondents. Respondents were also asked the type of medical school radiology education they received and to score the influence this experience had on their decision to pursue radiology. There were 202 total respondents (202/657) including 47 women and 155 men. Compared to men, the following factors had a more negative impact on women: flexible work hours (P = 0.04), work environment (P = 0.04), lifestyle (P = 0.04), impact on patient care (P = 0.05), high current debt load (P = 0.02), gender distribution of the field (P = 0.04), and use of emerging/advanced technology (P = 0.02). In contrast, women felt more favorably about the opportunities for leadership (P = 0.04) and research (P < 0.01). Dedicated radiology exposure was as follows: 20% (n = 20) none, 48% (n = 96) preclinical exposure, 55% (n = 111) elective rotation, and 18% (n = 37) core rotation. More intensive radiology exposure via a core rotation had a significantly positive impact on the decision to pursue radiology (P < 0.01). Male and female radiology applicants are motivated by different aspects of radiology, which may influence residency recruitment practices. In addition, more intensive radiology exposure has a net positive impact on the decision to pursue radiology. Copyright © 2017 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  6. Early indication for a reduced burden of radiologically confirmed pneumonia in children following the introduction of routine vaccination against Haemophilus influenzae type b in Nha Trang, Vietnam.

    Science.gov (United States)

    Flasche, Stefan; Takahashi, Kensuke; Vu, Dinh Thiem; Suzuki, Motoi; Nguyen, Thi Hien-Anh; Le, HuuTho; Hashizume, Masahiro; Dang, Duc Anh; Edmond, Karen; Ariyoshi, Koya; Mulholland, E Kim; Edmunds, W John; Yoshida, Lay-Myint

    2014-12-05

    Despite the global success of Hib vaccination in reducing disease and mortality, uncertainty about the disease burden and the potential impact of Hib vaccination in Southeast Asia has delayed the introduction of vaccination in some countries in the region. Hib vaccination was introduced throughout Vietnam in July 2010 without catch-up. In an observational, population based surveillance study we estimated the impact of routine Hib vaccination on all cause radiologically confirmed childhood pneumonia in Nha Trang, Vietnam. In 2007 active hospital based surveillance was established in Khanh Hoa General Hospital, the only hospital in Nha Trang, Khanh Hoa province. Nasopharyngeal samples and chest radiographs are taken routinely from all children diagnosed with acute respiratory illness on admission. For admissions between 02/2007 and 03/2012 chest radiographs were interpreted for the presence of WHO primary endpoint pneumonia and nasopharyngeal swabs were analysed by PCR for the presence of Influenza A or B, RSV and rhinovirus. We employed Poisson regression to estimate the impact of Hib vaccination on radiologically confirmed pneumonia (RCP) while statistically accounting for potential differences in viral circulation in the post vaccination era which could have biased the estimate. Of 3151 cases admitted during the study period, 166 had RCP and major viruses were detected in 1601. The adjusted annual incidence of RCP in children younger than 5 years declined by 39% (12-58%) after introduction of Hib vaccination. This decline was most pronounced in children less than 2 years old, adjusted IRR: 0.52 (0.33-0.81), and no significant impact was observed in the 2-4 years old who were not eligible for vaccination, adjusted IRR: 0.96 (0.52-1.72). We present early evidence that the burden of Hib associated RCP in Nha Trang before vaccination was substantial and that shortly after introduction to the routine childhood immunisation scheme vaccination has substantially reduced

  7. Potential radiological impacts of recovery of uranium from wet-process phosphoric acid. Final report to the Environmental Protection Agency

    International Nuclear Information System (INIS)

    Davis, W. Jr.; Haywood, F.F.; Danek, J.L.; Moore, R.E.; Wagner, E.B.; Rupp, E.M.

    1979-01-01

    A study was made to determine the radiological impacts associated with recovery of uranium from wet-process (WP) phosphoric acid in central Florida. Removal of U and other radionuclides from phosphoric acid prevents their distribution on farm lands and urban gardens and grasses via fertilizers; this results in a positive impact (decreased dose commitment) on the associated populations. This study considers the potential negative impacts of current and project recovery processes in a site-specific manner using detailed state-of-the-art methodologies. Positive impacts are treated in a generic sense using U.S. average values for important variables such as average and maximum fertilizer application rates and quantities of radionuclides in fertilizer. Three model plants to recover U from WP phosphoric acid were selected and source terms for release of radionuclides are developed for all three and for two treatment methods for airborne particulates. Costs for radwaste treatment were developed. Field measurements were conducted at the only commercial uranium recovery plant in operation. Radiological doses to the population surrounding release points during plant operation were estimated

  8. Generic environmental impact statement in support of rulemaking on radiological criteria for decommissioning of NRC-licensed nuclear facilities. Main report; Draft report for comment: Volume 1

    International Nuclear Information System (INIS)

    1994-08-01

    The action being considered in this draft Generic Environmental Impact Statement (GEIS) is an amendment to the Nuclear Regulatory Commission's (NRC) regulations in 10 CFR Part 20 to include radiological criteria for decommissioning of lands and structures at nuclear facilities. Under the National Environmental Policy Act (NEPA), all Federal agencies must consider the effect of their actions on the environment. To fulfill NRC's responsibilities under NEPA, the Commission is preparing this GEIS which analyzes alternative courses of action and the costs and impacts associated with those alternatives. In preparing the GEIS, the following approach was taken: (1) a listing was developed of regulatory alternatives for establishing radiological criteria for decommissioning; (2) for each alternative, a detailed analysis and comparison of incremental impacts, both radiological and nonradiological, to workers, members of the public, and the environment, and costs, were performed; and (3) based on the analysis of impacts and costs, preliminary recommendations were provided. Contained in the GEIS are recommendations related to the definition of decommissioning, the scope of rulemaking, the radiological criteria, restrictions on use, citizen participation, use of the GEIS in site-specific cases, and minimization of contamination

  9. Radiological impact of the PARR-1 operation on the environment

    International Nuclear Information System (INIS)

    Bakhtyar, S.; Raza, S.S.; Tayyab, M.; Pervez, S.; Salahuddin, A.

    2005-01-01

    This paper presents a study related to the assessment of the radiological impact on the environment due to the operation of the Pakistan research reactor-1 (PARR-1) at the Pakistan Institute of Nuclear Sciences and Technology (PINSTECH), Islamabad. The parameters studied include the radioactivity releases in a gaseous form and also those originating from the liquid and solid wastes produced due to the operation of this research facility. The analysis is based on the environmental monitoring data for the last 10 years (1992-2002) and the conclusions have been drawn for the impact of the PARR-1 operation on the occupational workers as well as the general public living in the vicinity of the reactor site. Further, on the basis of this data, yearly average doses and the cumulative doses for the expected life of PARR-1, due to different radiation sources have been estimated. The analysis indicated that the maximum yearly doses at ground level for the occupational workers as well as for the public are a fraction of the International Atomic Energy Agency's (IAEA) defined limiting values. It is, therefore, concluded that the impact of the PARR-1 normal operation on the environment is negligible and it can be regarded as ''safe to the public as well as the occupational workers''. (orig.)

  10. Virtual radiology rounds: adding value in the digital era

    International Nuclear Information System (INIS)

    Fefferman, Nancy R.; Strubel, Naomi A.; Prithiani, Chandan; Chakravarti, Sujata; Caprio, Martha; Recht, Michael P.

    2016-01-01

    To preserve radiology rounds in the changing health care environment, we have introduced virtual radiology rounds, an initiative enabling clinicians to remotely review imaging studies with the radiologist. We describe our initial experience with virtual radiology rounds and referring provider impressions. Virtual radiology rounds, a web-based conference, use remote sharing of radiology workstations. Participants discuss imaging studies by speakerphone. Virtual radiology rounds were piloted with the Neonatal Intensive Care Unit (NICU) and the Congenital Cardiovascular Care Unit (CCVCU). Providers completed a survey assessing the perceived impact and overall value of virtual radiology rounds on patient care using a 10-point scale. Pediatric radiologists participating in virtual radiology rounds completed a survey assessing technical, educational and clinical aspects of this methodology. Sixteen providers responded to the survey; 9 NICU and 7 CCVCU staff (physicians, nurse practitioners and fellows). Virtual radiology rounds occurred 4-5 sessions/week with an average of 6.4 studies. Clinicians rated confidence in their own image interpretation with a 7.4 average rating for NICU and 7.5 average rating for CCVCU. Clinicians unanimously rated virtual radiology rounds as adding value. NICU staff preferred virtual radiology rounds to traditional rounds and CCVCU staff supported their new participation in virtual radiology rounds. Four of the five pediatric radiologists participating in virtual radiology rounds responded to the survey reporting virtual radiology rounds to be easy to facilitate (average rating: 9.3), to moderately impact interpretation of imaging studies (average rating: 6), and to provide substantial educational value for radiologists (average rating: 8.3). All pediatric radiologists felt strongly that virtual radiology rounds enable increased integration of the radiologist into the clinical care team (average rating: 8.8). Virtual radiology rounds are a

  11. Virtual radiology rounds: adding value in the digital era

    Energy Technology Data Exchange (ETDEWEB)

    Fefferman, Nancy R.; Strubel, Naomi A.; Prithiani, Chandan; Chakravarti, Sujata; Caprio, Martha; Recht, Michael P. [New York University School of Medicine, Department of Radiology, New York, NY (United States)

    2016-11-15

    To preserve radiology rounds in the changing health care environment, we have introduced virtual radiology rounds, an initiative enabling clinicians to remotely review imaging studies with the radiologist. We describe our initial experience with virtual radiology rounds and referring provider impressions. Virtual radiology rounds, a web-based conference, use remote sharing of radiology workstations. Participants discuss imaging studies by speakerphone. Virtual radiology rounds were piloted with the Neonatal Intensive Care Unit (NICU) and the Congenital Cardiovascular Care Unit (CCVCU). Providers completed a survey assessing the perceived impact and overall value of virtual radiology rounds on patient care using a 10-point scale. Pediatric radiologists participating in virtual radiology rounds completed a survey assessing technical, educational and clinical aspects of this methodology. Sixteen providers responded to the survey; 9 NICU and 7 CCVCU staff (physicians, nurse practitioners and fellows). Virtual radiology rounds occurred 4-5 sessions/week with an average of 6.4 studies. Clinicians rated confidence in their own image interpretation with a 7.4 average rating for NICU and 7.5 average rating for CCVCU. Clinicians unanimously rated virtual radiology rounds as adding value. NICU staff preferred virtual radiology rounds to traditional rounds and CCVCU staff supported their new participation in virtual radiology rounds. Four of the five pediatric radiologists participating in virtual radiology rounds responded to the survey reporting virtual radiology rounds to be easy to facilitate (average rating: 9.3), to moderately impact interpretation of imaging studies (average rating: 6), and to provide substantial educational value for radiologists (average rating: 8.3). All pediatric radiologists felt strongly that virtual radiology rounds enable increased integration of the radiologist into the clinical care team (average rating: 8.8). Virtual radiology rounds are a

  12. Quality control in dental diagnostic radiology : anomalous in the use of radiological equipment

    International Nuclear Information System (INIS)

    Alcaraz, M.; Martinez-Beneyto, Y.; Jodar, S.; Velasco, E.; Garcia-Vera, M. C.

    2004-01-01

    7,176 official quality control reports on dental diagnostic radiology were studied, relating to dental clinics located in 37 Spanish provinces covering 16 different autonomous Regions. The reports were issued as a result of the entry into force of Royal Decree 2071/1995 on quality control in General Diagnostic Radiology facilities, this Royal Decree was replaced by R. D. 1976/1999. The reports were writen by the UTPR (Technical Unit of Radiological Protection) Agsigma S. A. L., a company approved by the Nuclear Safety Council, and they correspond with the official reports issued during 1996-2001. This meants that a 5-year period has been monitored in order to observe the impacts of the establlishment of this legislation on quality control in intraoral dental diagnostic radiology facilities. The results show that 72.79% of the reports checked in 2001 would comply with the European Union's official recommendation (70 kVp, 8 mA> 1.5 mm of Al and 20 cm collimator length). Significant alterations have detected in a third (30.59%) of the radiological equipment. (Author) 36 refs

  13. An analysis of radiological research publications in high impact general medical journals between 1996 and 2010.

    Science.gov (United States)

    Ku, You Jin; Yoon, Dae Young; Yun, Eun Joo; Baek, Sora; Lim, Kyoung Ja; Seo, Young Lan; Choi, Chul Soon; Bae, Sang Hoon

    2013-06-01

    To evaluate scientific papers published by radiologists in high impact general medical journals between 1996 and 2010. A MEDLINE search was performed in five high impact general medical journals (AIM, BMJ, JAMA, Lancet, and NEJM) for all articles of which a radiologist was the first author between 1996 and 2010. The following information was abstracted from the original articles: radiological subspecialty, imaging technique used, type of research, sample size, study design, statistical analysis, study outcome, declared funding, number of authors, collaboration, and country of the first author. Of 216 (0.19%) articles were published by radiologists in five general medical journals between 1996 and 2010, 83 were original articles. Fifteen (18.1%) original articles were concerned with the field of vascular/interventional radiology, 24 (28.9%) used combined imaging techniques, 76 (91.6%) were clinical research, 63 (75.9%) had a sample size of >50, 65 (78.3%) were prospective, 78 (94.0%) performed statistical analysis, 83 (100%) showed positive study outcomes, 57 (68.7%) were funded, 49 (59.0%) had from four to seven authors, and 79 (95.2%) were collaborative studies. A very small number (0.19%) in five high impact general medical journals was published by radiologists between 1996 and 2010. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  14. Radiological impact due to natural radionuclides (U and Th-isotopes) in soils from Salamanca, Mexico

    Energy Technology Data Exchange (ETDEWEB)

    Mandujano G, C. D.; Sosa, M. [Universidad de Guanajuato, Division de Ciencias e Ingenierias, Loma del Bosque 103, Col. Lomas del Campestre, 37150 Leon, Guanajuato (Mexico); Mantero, J.; Manjon, G.; Garcia T, R. [Universidad de Sevilla, Grupo en Fisica Nuclear Aplicada, Av. Reina Mercedes No. 2, 41012 Sevilla (Spain); Costilla, R., E-mail: cmandujano@fisica.ugto.mx [Universidad de Guanajuato, Division de Ciencias de la Vida, Departamento de Ciencias Ambientales, Ex-Hacienda El Copal Km 9 Irapuato-Silao, 36500 Irapuato, Guanajuato (Mexico)

    2015-10-15

    Full text: Activity concentrations of U ({sup 238}U, {sup 234}U) and Th ({sup 232}Th, {sup 230}Th) radionuclides in samples of superficial urban soils surrounding an industrial complex in Salamanca, Mexico have been determined. Levels of naturally occurring radionuclides (Norm) in the environment may be affected due to the presence of different industrial activities in this zone, representing a potential radiological risk for the population which should be evaluated. Alpha-particle Spectrometry with Pips detectors has been used for the radiometric characterization. A well established radiochemical procedure was used for the isolation of the radionuclides of interest. Alkali fusion for sample digestion, liquid-liquid extraction with Tbp (tri-butyl-phosphate) for U and Th isolation and electrodeposition in stainless steel dishes for measurement conditioning has been used. The results cover the ranges of 10-42, 12-60, 12-52 and 11-51 Bq·kg{sup -1} for {sup 238}U, {sup 234}U, {sup 230}Th, and {sup 232}Th respectively, being not observed any clear anthropogenic increments in relation with the values normally found in unaffected soils. Although there is disequilibrium between U isotopes and {sup 230}Th in some soil samples, it can be attributed to natural processes. The radiological impact of the industrial activities in the surrounding soils can be then evaluated as very low. Hence, from the Radiological Protection point of view, the soils studied do not represent a radiological risk for the health of the population. (Author)

  15. Study and radiological impact assesstment produced by activities of different non-nuclear industries. Titanium dioxide industries; Estudio y evaluacion del impacto radiologico producido por las actividades de diversas industrias no nucleares en el sur de Espana. Industrias de dioxido de titanio

    Energy Technology Data Exchange (ETDEWEB)

    Garcia-Tenorio, R.; Manjon, G.; Abril, J.M. (and others)

    2010-07-01

    After a careful study and evaluation of radiological impact, the conclusiono is that these industries do not need to be subject to control, and it is not necessary any corrective action to reduce the exposition and/or to apply any radiation protection measures.

  16. Study and radiological impact assessment produced by activities of different non-nuclear industries. Titanium dioxide industries; Estudio y evaluacion del impacto radiologico producido por las actividades de diversas industrias no nucleares en el sur de Espana. Industrias de dioxido de titanio

    Energy Technology Data Exchange (ETDEWEB)

    Garcia-Tenorio, R.; Manjon, G.; Abril, J.M.

    2010-07-01

    After a careful study and evaluation of radiological impact, the conclusion is that these industries do not need to be subject to control, and it is not necessary any corrective action to reduce the exposition and/or to apply any radiation protection measures.

  17. Control of radiological impacts in deactivated uranium mine - the portuguese experience

    International Nuclear Information System (INIS)

    Pereira, Alcides; Neves, Luis

    2011-01-01

    The exploration of radioactive ores occurred in Portugal during around 100 years, and on that period 4370 tons were produced of uranium concentrate, and an estimated total of 13 millions of tons of residues, of various type and variable dangerous grade. From the year 2000 that the government has been performed studies on environmental characterization at the mining areas and remediation project as well. The precise evaluation of the environmental impacts implies the the knowledge of prior work situation, nonexistent for the case of Portuguese mines. This work proposes a methodology for exceeding that limitation focused on selection of area sited at the same metallogenetic province, and considered representative of background. The radiological impacts are checked by the effective dose calculated for reference groups of the exposed population, at this region and in the principal mining area at Portugal (Urgeirica), at the end of exploration and after the finalization of some remediation works

  18. Investigation of whether various types of radioactive waste are equivalent in terms of the radiological impact associated with their disposal

    International Nuclear Information System (INIS)

    Fearn, H.S.; Smith, G.M.; Davis, J.P.; Hill, M.D.

    1989-01-01

    The aim of this study is to investigate the possibility that various types of waste are equivalent in terms of the risks associated with their disposal in so far as they are viewed by different sections of society. If such a framework can be established it could be used as an aid to decisions as to whether central disposal facilities, to accept waste from several countries, should be constructed. Details are presented of assumed radionuclide inventories for a representative range of radioactive wastes, calculations and results of the radiological impacts of their disposal, and illustrative methods for weighting the various components of impact which when summed provide an overall measure of impact. Five sets of weighting factors have been devised which are intended to represent the views of a) the radiological protection community, b) those with a pro-nuclear industry view, c) those who oppose nuclear power on safety grounds, d) the inhabitants of the country receiving wastes for disposal, and e) the inhabitants of the country dispatching wastes. On the basis of the calculated weighted radiological impacts it is demonstrated how conclusions can be drawn about general views on the disposal of each waste, about likely attitudes to the export of wastes from one country for disposal in another, and attitudes to exchanging wastes between countries. The study is preliminary and of limited scope. However, the results show that the general methodology is practicable and could be applied in a wider ranging investigation

  19. The leaded apron revisited: does it reduce gonadal radiation dose in dental radiology

    Energy Technology Data Exchange (ETDEWEB)

    Wood, R.E.; Harris, A.M.; van der Merwe, E.J.; Nortje, C.J. (Ontario Cancer Institute, Princess Margaret Hospital, Toronto (Canada))

    1991-05-01

    A tissue-equivalent anthropomorphic human phantom was used with a lithium fluoride thermoluminescent dosimetry system to evaluate the radiation absorbed dose to the ovarian and testicular region during dental radiologic procedures. Measurements were made with and without personal lead shielding devices consisting of thyroid collar and apron of 0.25 mm lead thickness equivalence. The radiation absorbed dose with or without lead shielding did not differ significantly from control dosimeters in vertex occlusal and periapical views (p greater than 0.05). Personal lead shielding devices did reduce gonadal dose in the case of accidental exposure (p less than 0.05). A leaded apron of 0.25 mm lead thickness equivalent was permeable to radiation in direct exposure testing.

  20. The leaded apron revisited: does it reduce gonadal radiation dose in dental radiology

    International Nuclear Information System (INIS)

    Wood, R.E.; Harris, A.M.; van der Merwe, E.J.; Nortje, C.J.

    1991-01-01

    A tissue-equivalent anthropomorphic human phantom was used with a lithium fluoride thermoluminescent dosimetry system to evaluate the radiation absorbed dose to the ovarian and testicular region during dental radiologic procedures. Measurements were made with and without personal lead shielding devices consisting of thyroid collar and apron of 0.25 mm lead thickness equivalence. The radiation absorbed dose with or without lead shielding did not differ significantly from control dosimeters in vertex occlusal and periapical views (p greater than 0.05). Personal lead shielding devices did reduce gonadal dose in the case of accidental exposure (p less than 0.05). A leaded apron of 0.25 mm lead thickness equivalent was permeable to radiation in direct exposure testing

  1. Foods Found in the Wild Around Nuclear Sites: An Evaluation of Radiological Impact

    International Nuclear Information System (INIS)

    Green, N.; Wilkins, B.T.; Hammond, D.J.; Davidson, M.F.; Richmond, S.; Brooker, S.

    2001-01-01

    Habit surveys were carried out around four licensed nuclear sites to identify people who collect foodstuffs from the wild (so-called 'free foods'). In total, around 800 collectors were readily identified, most of whom collected more than one free food. The data indicated that estimates of higher than average doses could reasonably be based on the three foodstuffs of most importance. Foods were selected for further study on the basis of either the number of collectors or the amount consumed. The radionuclides of interest were identified using published information on the discharges from each site. The resultant average and higher than average doses were estimated using the site-specific habit data. For all sites, doses from the consumption of free foods were low and of no radiological importance. Assessments based solely on data for cultivated foods would not therefore have underestimated radiological impact significantly. However, given the wide utilisation of free foods found in this study, for rigorous assessments it would be prudent to take account of the consumption of foods from the wild. (author)

  2. Improving patient follow-up in interventional radiology and radiation-based acts. To reduce the risk of deterministic effects

    International Nuclear Information System (INIS)

    Etard, Cecile; Aubert, Bernard; Lafont, Marielle; Mougniot, Sandrine; Rousse, Carole; Bey, Eric; Cassagnes, Lucie; Guersen, Joel; Ducou Le Pointe, Hubert; Elhadad, Simon; Georges, Jean-Louis; Nonent, Michel; Paisant-Thouveny, Francine; Salvat, Cecile; Vidal, Vincent; Chauvet, Bruno; Riu, Jean-Luc; Voix, Fabien; Bar, Olivier; Le Du, Dominique; Maccia, Carlo; Lacombe, Pascal; Mertz, Luc; Valery, Charles

    2014-04-01

    After having presented an example of adverse reaction to interventional radiology (a case of a iatrogenic radiodermatitis), this report first presents the context which creates a risk situation. It describes risks related to the use of ionizing radiations, identifies risk factors and how to make procedures safer, and indicates actions aimed at reducing risks (in a preventive way, in recovery, by attenuation)

  3. Strategic Expansion Models in Academic Radiology.

    Science.gov (United States)

    Natesan, Rajni; Yang, Wei T; Tannir, Habib; Parikh, Jay

    2016-03-01

    In response to economic pressures, academic institutions in the United States and their radiology practices, are expanding into the community to build a larger network, thereby driving growth and achieving economies of scale. These economies of scale are being achieved variously via brick-and-mortar construction, community practice acquisition, and partnership-based network expansion. We describe and compare these three expansion models within a 4-part framework of: (1) upfront investment; (2) profitability impact; (3) brand impact; and (4) risk of execution. Copyright © 2016 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  4. The impact of education on occupational radiation exposure reduction in a diagnostic radiology department

    International Nuclear Information System (INIS)

    Vetter, R.J.; Gray, J.E.

    1987-01-01

    Patient load, number of radiographic exams, complexity of some exams, and associated potential occupational radiation exposure of medical personnel have increased significantly in the past decade. Efforts to reduce exposure through employee education and awareness have resulted in significant reduction in occupational exposure for most diagnostic radiographic areas at Mayo Clinic. This paper reviews trends in occupational radiation exposure from diagnostic x- rays at Mayo Clinic over the past ten years. Changes in employee radiation dose equivalents are correlated with patient workload, complexity of exams, increased interventional radiology and cardiology, and efforts to reduce employee radiation exposure

  5. Educational treasures in Radiology: The Radiology Olympics - striving for gold in Radiology education

    OpenAIRE

    Talanow, Roland

    2010-01-01

    This article focuses on Radiology Olympics (www.RadiologyOlympics.com) - a collaboration with the international Radiology community for Radiology education, Radiolopolis (www.Radiolopolis.com). The Radiology Olympics honour the movers and shakers in Radiology education and offer an easy to use platform for educating medical professionals based on Radiology cases.

  6. Radiology

    International Nuclear Information System (INIS)

    Bigot, J.M.; Moreau, J.F.; Nahum, H.; Bellet, M.

    1990-01-01

    The 17th International Congress of Radiology was conducted in two separate scientific sessions, one for radiodiagnosis and one for radiation oncology. Topics covered are: Radiobiology -radioprotection; imaging and data processing; contrast media; MRI; nuclear medicine; radiology and disasters; radiology of tropical diseases; cardiovascular radiology; interventional radiology; imaging of trauma; imaging of chest, gastro-intestinal tract, breast and genito-urinary tract; imaging in gynecology;imaging in oncology; bone and joint radiology; head and neck-radiology; neuro-radiology. (H.W.). refs.; fig.; tabs

  7. Estimation of the radiological impact in the use of phosphate fertilizer in citric plantations

    International Nuclear Information System (INIS)

    Zerquera, J.T.; Prendes A, M.; Alonso J, M.T.; Perez S, D.

    1996-01-01

    The use of fertilizers in the agriculture is a potential danger of environmental contamination, because the elements contained in them could suffer an important redistribution in the environment. This is the case of radioactive elements of natural origin, like K-40 and nuclides of U and Th series, present in the ores used in the production of industrial fertilizers. Phosphoric rocks used in fertilizers contain, generally, important concentrations of radioactive elements greater than other rocks of the earth core. In Cuba, preliminary determinations of Ra-226 concentrations in phosphoric rocks reveal results in the order of 2.7 Bq/kg. These values are greater than the mean of the rest of soils of the country. Due to this fact, a study on the radiological impact of this practice was developed. The study was carried out in citric plantations of the province of Pinar del Rio, where phosphate fertilizer is widely used. Samples of different parts of the plant were taken and analyzed by means of gamma spectrometric techniques. The paper presents values for Ra-226 that are in the range 27-40 Bq/kg. These results show that the use of fertilizers does not imply a significant radiological impact. Punctual valves of transfer coefficients of Ra-226 in soil -stem-leave-peel and - juice chains were estimated. (authors). 6 refs., 4 tabs

  8. Scenarios of radiological impacts in the long-term safety analysis of radioactive waste disposal at the Vector Site located in the Chernobyl exclusion zone

    Energy Technology Data Exchange (ETDEWEB)

    Rybalka, N.; Mykolaichuk, O. [State Nuclear Regulatory Inspectorate of Ukraine, Kyiv (Ukraine); Alekseeva, Z.; Kondratiev, S.; Nikolaev, E. [State Scientific and Technical Center for Nuclear and Radiation Safety, Kyiv (Ukraine)

    2013-07-01

    In Ukraine, at the Vector site in the Chernobyl exclusion zone, it is planned to dispose of large amounts of radioactive wastes, including those of Chernobyl origin, containing transuranium elements. The paper analyzes the main possible scenarios of radiological impacts of the Vector site for a long-term period after expiration of its active administrative control taking into account location of the Vector site in the exclusion zone. In the paper, assessment of total activities that can be disposed of on site is demonstrated, based on non-exceeding of admissible radiological impacts. (orig.)

  9. Recommended protocol for standardization in collecting and interpreting radiological environmental data

    International Nuclear Information System (INIS)

    Denham, D.H.; Kathren, R.L.

    1989-02-01

    Current reductions in ''allowable'' levels of radiation and radioactive materials in the environment and an increased public awareness of naturally occurring radioactive materials have reinforced the need for consistency in evaluating the radiological environment. A key concern is the identification and interpretation of environmental levels of radiation and radioactive materials resulting from nuclear facility operations. If these levels can be detected and their source(s) identified, then corrective actions can be taken to eliminate or greatly reduce the environmental impacts of the facility operations. In this paper we address the lack of definitive guidance necessary to determine incremental levels of significance (or insignificance), and we propose a series of protocols to achieve more consistent collection and interpretation of radiological environmental data. 8 refs

  10. Monitoring of the radiological environmental impact of the AREVA site of Tricastin; Suivi de l'impact radiologique environnemental des activites du site AREVA du Tricastin

    Energy Technology Data Exchange (ETDEWEB)

    Mercat, C.; Brun, F.; Florens, P.; Petit, J. [AREVA NC Pierrelatte, Direction surete environnement du site du Tricastin, 26 (France); Garnier, F. [EURODIF Production, Direction qualite securite surete environnement, 26 (France); Devin, P. [AREVA NC Pierrelatte, Direction surete, sante, securite, environnement, 26 (France)

    2010-06-15

    Set up at the beginning of the site's operations, in 1962, the monitoring of the radiological environmental impact of the AREVA site of Tricastin has evolved over time to meet more specifically the multiple objectives of environmental monitoring: to prove the respect of the commitments required by the authorities, to be able to detect a dysfunction in the observed levels, to enable the assessment of impacts of industrial activities, to ensure the balance between environmental quality and the use made by the local population and to inform the public of the radiological state of the environment. Thousands of data were acquired on the radioactivity of all environmental compartments as well as on the functioning of local ecosystems. Today, the Network of Environmental Monitoring of AREVA Tricastin goes beyond the requirements of routine monitoring to provide innovative solutions for monitoring the radioactivity (especially for uranium) in the environment. (author)

  11. Radiological impact of the application of phosphogypsum in agriculture

    Energy Technology Data Exchange (ETDEWEB)

    Mazzilli, B.P.; Saueia, C.H.R., E-mail: chsaueia@ipen.b, E-mail: mazzilli@ipen.b [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil). Lab de Radiometria Ambiental

    2011-07-01

    Phosphogypsum is a TENORM waste and one possible of this application is in agriculture. This paper aims to evaluate the dose due to ingestion of natural radionuclides present in phosphogypsum that could be incorporated in the food chain. For this evaluation, a conservative scenario was defined, considering a theoretical long term exposure due to annual applications of phosphogypsum in agriculture. This scenario covers estimation of the increment of radionuclides activity concentration in soil due to phosphogypsum applications; the uptake from soil by edible portions of vegetable and crops and activity concentration of radionuclides in milk and meat as part of the food chain; based on a model, transfer factors and conversion factors provided by IAEA and ICRP. The higher doses were found for the ingestion of vegetables and grain crop, up to 4.2 10-1 mSv per year. It is concluded that the radiological impact of this practice is negligible. (author)

  12. Radiological impact of the application of phosphogypsum in agriculture

    International Nuclear Information System (INIS)

    Mazzilli, B.P.; Saueia, C.H.R.

    2011-01-01

    Phosphogypsum is a TENORM waste and one possible of this application is in agriculture. This paper aims to evaluate the dose due to ingestion of natural radionuclides present in phosphogypsum that could be incorporated in the food chain. For this evaluation, a conservative scenario was defined, considering a theoretical long term exposure due to annual applications of phosphogypsum in agriculture. This scenario covers estimation of the increment of radionuclides activity concentration in soil due to phosphogypsum applications; the uptake from soil by edible portions of vegetable and crops and activity concentration of radionuclides in milk and meat as part of the food chain; based on a model, transfer factors and conversion factors provided by IAEA and ICRP. The higher doses were found for the ingestion of vegetables and grain crop, up to 4.2 10-1 mSv per year. It is concluded that the radiological impact of this practice is negligible. (author)

  13. Assessment of the radiological quality of tap waters 2008-2009

    International Nuclear Information System (INIS)

    Caamano, Delphine; Tracol, Raphael; Guillotin, Laetitia; Jedor, Beatrice; Davezac, Henri; Loyen, Jeanne

    2011-06-01

    After a recall of the context (radioactivity, origin of natural radioactivity in waters, exposure of population to natural radioactivity and health impact, indicators of water radiological quality, presence of uranium in water), this document reports a study which is based on the health control of water radiological quality by regional health agencies, on the analysis of natural and artificial radionuclides, on a survey on tap water radiological quality performed in 2009 by regional health agencies, and on an inventory of results related to the presence of radon in water performed by the IRSN and these agencies. The obtained results are presented and discussed in terms of factors impacting the result representativeness, of generalisation of the implementation of a health control, of tap water radiological quality. It is outlined that the uranium-related chemical risk is higher than the radiological risk

  14. RADIOPROTECTION CAMPAIGN AND CARD: EDUCATIONAL STRATEGIES THAT REDUCE CHILDREN'S EXCESSIVE EXPOSURE TO RADIOLOGICAL EXAMS.

    Science.gov (United States)

    Bernardo, Mônica Oliveira; Almeida, Fernando Antonio de; Morgado, Flavio

    2017-01-01

    To analyze the results of an initiative aimed at improving the reasonable use of radiological examinations, ensuring their technical quality, implementing a radioprotection campaign that includes training of the professional team, and introducing the radioprotection card for children under 12 years old as a tool for parents and doctors to control children's exposure to radiation. The study was held in a health care insurance system covering 140,000 people. A radioprotection campaign was implemented according to Image Gently • protocols, ensuring the lowest dose of radiation and the quality of examinations, and the radioprotection card was implemented. To assess the effectiveness of these actions, the number of radiological examinations performed at the pediatric emergency room in a period of one year preceding the campaign was compared with the number of radiological examinations performed one year after the campaign. The campaign was well accepted by all professionals, families, and patients involved. In the year following the implementation of radioprotection strategies, there was a 22% reduction of radiological examinations performed at the pediatric emergency room. There was also a 29% reduction in the request of two or more radiological examinations for the same child or examinations with two or more incidences. The campaign and the radioprotection card for children under 12 years old proved to be feasible strategies and correlated with a reduction in radiological examinations requested and performed at the pediatric emergency room.

  15. Association of h-index of Editorial Board Members and Impact Factor among Radiology Journals.

    Science.gov (United States)

    Asnafi, Solmaz; Gunderson, Tina; McDonald, Robert J; Kallmes, David F

    2017-02-01

    h-Index has been proposed as a useful bibliometric measure for quantifying research productivity. In this current study, we analyzed h-indices of editorial board members of Radiology journals and tested the hypothesis that editorial board members of Radiology journals with higher impact factors (IF) have higher h-indices. Sixty-two Radiology journals with IF >1 were included. Editorial board members were identified using the journals' websites. Editors' affiliations and research fields of interest were used to distinguish investigators with similar names. Bibliometric indices including number of publications, total citations, citations per publication, and h-index for each editorial board member were obtained using the Web of Science database. Chi-square or Wilcoxon rank-sum tests were used to test for differences in bibliographic measures or demographics between groups. Among the editorial boards of 62 journals, the median [interquartile range] board h-index was 26 [18, 31] and had 36 [17, 56] members. The median journal IF was 2.27 [1.74, 3.31]. We identified a total of 2204 distinct editors; they had a median [interquartile range] h-index of 23 [13, 35], 120 [58, 215] total publications, 1938 [682, 4634] total citations, and an average of 15.7 [9.96, 24.8] citations per publication. The boards of journals with IF above the median had significantly higher h-indices (P = .002), total publications (P = .01), and total and average citations (both any [P = .003, .009] and nonself-citations [P = .001, .002]) than journals below the median. Our data indicate that board members of Radiology journals with higher IF have greater h-indices compared to lower IF journals. Copyright © 2017 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  16. Radiological scenario modeling using the Hotspot code and potential financial impact of treatment of radiation induced cancer to the public

    International Nuclear Information System (INIS)

    Silva, Gabriel Fidalgo Queiroz da; Andrade, Edson Ramos de; Rebello, Wilson Freitas; Araujo, Olga Maria Oliveira de

    2015-01-01

    The work aims to develop a methodology that is able to estimate the financial impact in a radiological emergency events, considering the radiation induced cancer, particularly leukemia. Considering a RDD - Radiological Dispersive Device, consisting of explosives and cesium-137 as radioactive material, a scenario building on the Rio de Janeiro was modeled. The convergence of a risk modeling platform (HotSpot 3.0), the analysis of excess relative risks for humans (BEIR V-Biological Effects of Ionizing Radiation V), considering scenarios composed of contaminated areas, are secondary goals

  17. Does gender impact upon application rejection rate among Canadian radiology residency applicants?

    Science.gov (United States)

    Baerlocher, Mark O; Walker, Michelle

    2005-10-01

    To determine if and how gender ratios have changed within Canadian radiology, and to determine if gender discrimination occurs at the level of the radiology resident selection committee. The Canadian Medical Association, Canadian Association of Radiologists, Canadian Institute for Health Information, Royal College of Physicians and Surgeons of Canada, and Canadian Residency Matching Service provided gender-specific data. We compared the proportion of female applicants who ranked a radiology program as their top choice and were rejected from any radiology program with the corresponding proportion for male applicants. The numbers of women and men being awarded an MD from a Canadian university equalized nearly a decade ago. Women continue to be numerically underrepresented among practicing radiologists; however, the proportion of women continues to increase so that there is 1 female radiologist in practice to every 3 male radiologists in practice in 2005. More male medical students ranked a radiology residency training program as their top choice in the residency match; however, of those who did, they were as likely as women to be rejected from a radiology residency training program. Grouping all female and male graduating medical students participating in the residency match and ranking a radiology residency as their top choice between 1993 and 2004, the odds of men being rejected were 1.4 times (95% CI 0.99-1.9, p = 0.07) greater than for women. There continues to be more men than women radiologists in practice; however, the female-to-male ratio continues to increase. Our data suggest that discrimination against female applicants at the level of radiology residency selection does not occur.

  18. Radiation protection during radiological examinations of children

    International Nuclear Information System (INIS)

    Claus, D.; Gillet, R.; Wambersie, A.

    The dose delivered to children during radiological examinations were assessed and their variations compared with an experimental model. It is shown how to make good radiological examinations limiting the dose delivered to children and reducing the hazard to the medical staff [fr

  19. Radiology applications of financial accounting.

    Science.gov (United States)

    Leibenhaut, Mark H

    2005-03-01

    A basic knowledge of financial accounting can help radiologists analyze business opportunities and examine the potential impacts of new technology or predict the adverse consequences of new competitors entering their service area. The income statement, balance sheet, and cash flow statement are the three basic financial statements that document the current financial position of the radiology practice and allow managers to monitor the ongoing financial operations of the enterprise. Pro forma, or hypothetical, financial statements can be generated to predict the financial impact of specific business decisions or investments on the profitability of the practice. Sensitivity analysis, or what-if scenarios, can be performed to determine the potential impact of changing key revenue, investment, operating cost or financial assumptions. By viewing radiology as both a profession and a business, radiologists can optimize their use of scarce economic resources and maximize the return on their financial investments.

  20. Monitoring techniques for the impact assessment during nuclear and radiological emergencies: current status and the challenges

    International Nuclear Information System (INIS)

    Pradeepkumar, K.S.; Sharma, D.N.

    2003-01-01

    Preparedness and response capability for Nuclear and Radiological emergencies, existing world over, are mainly based on the requirement of responding to radiation emergency caused by nuclear or radiological accidents. Cosmos satellite accident, plutonium contamination at Polaris, nuclear accidents like Kystium, Windscale, TMI and Chernobyl, radiological accidents at Goiania etc have demonstrated the requirement of improved radiation monitoring techniques. For quick decision making, state of the art monitoring methodology which can support quantitative and qualitative impact assessment is essential. Evaluation of radiological mapping of the area suspected to be contaminated needs ground based as well as aerial based monitoring systems to predict the level of radioactive contamination on ground. This will help in delineating the area and deciding the required countermeasures, based on the quantity and type of radionuclides responsible for it. The response can be successful with the effective use of i) Early Warning System ii) Mobile Monitoring System and iii) Aerial Gamma Spectrometric System. Selection of the monitoring methodology and survey parameters and assessment of situation using available resources etc. are to be optimized depending on the accident scenario. Recently, many countries and agencies like IAEA have expressed the requirement for responding to other types of nuclear/radiological emergencies i.e, man made radiation emergency situations aimed at harming public at large that can also lead to environmental contamination and significant exposure to public. Reports of lost / misplaced / stolen radioactive sources from many countries are alarming as safety and security of these radioactive sources are under challenge. The monitoring methodology has to take into account of the increase in such demands and more periodic monitoring in suspected locations is to be carried out. Detection of orphan sources possible amidst large heap of metallic scraps may pose

  1. Pediatric radiology malpractice claims - characteristics and comparison to adult radiology claims

    Energy Technology Data Exchange (ETDEWEB)

    Breen, Micheal A.; Taylor, George A. [Boston Children' s Hospital, Department of Radiology, Boston, MA (United States); Dwyer, Kathy; Yu-Moe, Winnie [CRICO Risk Management Foundation, Boston, MA (United States)

    2017-06-15

    implicated in pediatric radiology claims was radiography. The highest payouts in pediatric radiology pertained to missed congenital and developmental anomalies (average $1,222,932) such as developmental dysplasia of the hip and congenital central nervous system anomalies. More than half of pediatric radiology claims arose in the ambulatory setting. Pediatric radiology is not immune from claims of medical malpractice and these claims result in high monetary payouts, particularly for missed diagnoses of congenital and developmental anomalies. Our data suggest that efforts to reduce diagnostic error in the outpatient radiology setting, in the interpretation of radiographs, and in the improved diagnosis of fractures and congenital and developmental anomalies would be of particular benefit to the pediatric radiology community. (orig.)

  2. Pediatric radiology malpractice claims - characteristics and comparison to adult radiology claims

    International Nuclear Information System (INIS)

    Breen, Micheal A.; Taylor, George A.; Dwyer, Kathy; Yu-Moe, Winnie

    2017-01-01

    pediatric radiology claims was radiography. The highest payouts in pediatric radiology pertained to missed congenital and developmental anomalies (average $1,222,932) such as developmental dysplasia of the hip and congenital central nervous system anomalies. More than half of pediatric radiology claims arose in the ambulatory setting. Pediatric radiology is not immune from claims of medical malpractice and these claims result in high monetary payouts, particularly for missed diagnoses of congenital and developmental anomalies. Our data suggest that efforts to reduce diagnostic error in the outpatient radiology setting, in the interpretation of radiographs, and in the improved diagnosis of fractures and congenital and developmental anomalies would be of particular benefit to the pediatric radiology community. (orig.)

  3. Pediatric radiology malpractice claims - characteristics and comparison to adult radiology claims.

    Science.gov (United States)

    Breen, Micheál A; Dwyer, Kathy; Yu-Moe, Winnie; Taylor, George A

    2017-06-01

    pediatric radiology claims was radiography. The highest payouts in pediatric radiology pertained to missed congenital and developmental anomalies (average $1,222,932) such as developmental dysplasia of the hip and congenital central nervous system anomalies. More than half of pediatric radiology claims arose in the ambulatory setting. Pediatric radiology is not immune from claims of medical malpractice and these claims result in high monetary payouts, particularly for missed diagnoses of congenital and developmental anomalies. Our data suggest that efforts to reduce diagnostic error in the outpatient radiology setting, in the interpretation of radiographs, and in the improved diagnosis of fractures and congenital and developmental anomalies would be of particular benefit to the pediatric radiology community.

  4. Radiological impact of drinks intakes of naturally occurring radionuclides on adults of central zone of Malaysia

    International Nuclear Information System (INIS)

    Tawalbeh, A.A.; Samat, S.B.; Muhammad Samudi Yasir; Muhamat Omar

    2012-01-01

    Fifty three samples of different types of imported and locally produced drinks consumed in central zone of Malaysia were analyzed using gamma-ray spectrometry system. The measurement was conducted for 12 hours using a Canberra p-type high purity germanium (HPGe) gamma spectrometer with 30 % relative efficiency resolution of 1.8 keV at 1.33 MeV. The detector was connected to a computer with MCA card (Accuspec B) and Genie-2000 Analysis software of Canberra Industries, USA. The geometric means of daily intakes of 238 U, 232 Th and 40 K were 0.05, 0.08 and 27.23 respectively. Also the values give annual committed effective doses of 0.8, 6.5 and 61.53 μSv yr -1 for 238 U, 232 Th and 40 K, respectively for population in central zone of Malaysia. The net radiological impact of these radionuclides is 68.83 μSv yr -1 . This value gives cancer risk factor of 1.72 x 10 -7 . Also the value of net radiological impact gives loss of life expectancy of 0.43 days only. Whereas ICRP cancer risk factor for general public is 2.5 x 10 -3 and total risk involve from the all natural radiation sources based on global average annual radiation dose of 2.4 mSv yr -1 is 6.0 x 10 -3 . The estimated cancer risk shows that probability of increase of cancer risk from daily Malaysian drinks is only a minor fraction of ICRP values. Therefore the drink samples investigated here does not pose any significant health hazard and is considered radiologically safe for human consumption. (author)

  5. Radiological Dispersion Devices: are we prepared?

    Energy Technology Data Exchange (ETDEWEB)

    Sohier, Alain [Decision Strategy Research Department (Radiation Protection Division), Belgian Nuclear Research Centre (SCK-CEN), Boeretang 200, B-2400 Mol (Belgium)]. E-mail: asohier@sckcen.be; Hardeman, Frank [Decision Strategy Research Department (Radiation Protection Division), Belgian Nuclear Research Centre (SCK-CEN), Boeretang 200, B-2400 Mol (Belgium)

    2006-07-01

    Already before the events of September 11th 2001 concern was raised about the spread of orphan sources and their potential use in Radiological Dispersion Devices by terrorist groups. Although most of the simulated scenarios foresee a rather limited direct health impact on the population, the affected region would suffer from the indirect consequences such as social disruption, cleanup requirements and economic costs. The nature of such a radiological attack would anyway be different compared to conventional radiological accidents, basically because it can happen anywhere at any time. Part of the response resides in a general preparedness scheme incorporating attacks with Radiological Dispersion Devices. Training of different potential intervention teams is essential. The response would consist of a prioritised list of actions adapted to the circumstances. As the psychosocial dimension of the crisis could be worse than the purely radiological one, an adapted communication strategy with the public aspect would be a key issue.

  6. Radiological Dispersion Devices: are we prepared?

    International Nuclear Information System (INIS)

    Sohier, Alain; Hardeman, Frank

    2006-01-01

    Already before the events of September 11th 2001 concern was raised about the spread of orphan sources and their potential use in Radiological Dispersion Devices by terrorist groups. Although most of the simulated scenarios foresee a rather limited direct health impact on the population, the affected region would suffer from the indirect consequences such as social disruption, cleanup requirements and economic costs. The nature of such a radiological attack would anyway be different compared to conventional radiological accidents, basically because it can happen anywhere at any time. Part of the response resides in a general preparedness scheme incorporating attacks with Radiological Dispersion Devices. Training of different potential intervention teams is essential. The response would consist of a prioritised list of actions adapted to the circumstances. As the psychosocial dimension of the crisis could be worse than the purely radiological one, an adapted communication strategy with the public aspect would be a key issue

  7. Assessment of management alternatives for LWR wastes. Volume 8. Cost and radiological impact associated with near-surface disposal of reactor waste (Spanish concept)

    International Nuclear Information System (INIS)

    Alamo Berna, S.; Sanchez Delgado, N.

    1993-01-01

    This report deals with the determination of the cost and the radiological impact associated with a near-surface disposal site (Spanish concept) for low and medium-level radioactive waste generated during operation of a 20 GWe nuclear park composed of LWRs for 30 years. This study is part of an overall theoretical exercise aimed at evaluating a selection of management routes for LWR waste based on economical and radiological criteria

  8. Assessment of management alternatives for LWR wastes. Volume 7. Cost and radiological impact associated with near-surface disposal of reactor waste (French concept)

    International Nuclear Information System (INIS)

    Malherbe, J.

    1993-01-01

    This report deals with the determination of the cost and the radiological impact associated with a near-surface disposal site (French concept) for low and medium-level radioactive waste generated during operation of a 20 GWe nuclear park composed of LWRs for 30 years. This study is part of an overall theoretical exercise aimed at evaluating a selection of management routes for LWR waste based on economical and radiological criteria

  9. Highly cited works in radiology: the top 100 cited articles in radiologic journals.

    Science.gov (United States)

    Pagni, Matthew; Khan, Nickalus R; Cohen, Harris L; Choudhri, Asim F

    2014-08-01

    The number of citations a publication receives can be used to show its impact on a field of study. It may indicate the educational interest in a given population or underline a perceived or real educational gap. This article identifies and characterizes the 100 top cited publications in radiologic journals as of May 2013. All clinical radiologic journals listed by Thomson Reuters Journal Citation Reports in 2011 were identified. A total of 46 journals were identified, and all articles published within these journals were analyzed for citation counts. The top 100 highly cited articles were recorded. The most frequently cited radiologic articles appeared in 9 of the 46 journals. These included 59 articles in Radiology, 17 in Journal of Nuclear Medicine, 9 in the American Journal of Roentgenology, 5 in the British Journal of Radiology, 4 in Investigative Radiology, 2 in American Journal of Neuroradiology, 2 in European Radiology, 2 in Radiologic Clinics of North America, 1 in the Seminars in Nuclear Medicine, and 1 in Pediatric Radiology. The citation values ranged from 422 to 7506 with a mean of 751. Publication dates ranged from 1967 to 2006 with the 5-year period between 1986 and 1990 accounting for the largest percentage of articles. The most frequently studied radiologic modality was magnetic resonance imaging (MRI; 28 articles), followed by vascular/interventional (19 articles) and nuclear medicine (13 articles). The central nervous system was the most frequently studied organ system (22 articles), followed by mixed organ systems (14 articles) and liver (12 articles). The top cited articles in radiologic journals span a wide range of imaging modalities, subspecialties, and organ systems. Topics that occurred frequently in the top 100 cited articles included contrast and radiopharmaceutical characterization, MRI of motion, percutaneous radiofrequency ablation in the liver and percutaneous vertebroplasty. We present a methodology that uses citation analysis to

  10. Proposed Nuclear Power Plants in the UK-Potential Radiological Implications for Ireland

    International Nuclear Information System (INIS)

    McMahon, C.; Kelleher, K.; McGinnity, P.; Organo, C.; Smith, K.; Currivan, L.; Ryan, T.

    2013-05-01

    The UK Government has identified up to eight locations for the construction of new nuclear power plants by 2025. Five of these locations are on the Irish Sea coast. The Radiological Protection Institute of Ireland, RPII was requested by the Minister for the Environment, Community and Local Government to undertake an assessment of the potential radiological impacts on Ireland from this New Build Programme. This report presents the findings of the potential impacts on Ireland of both the anticipated routine radioactive discharges and of a range of postulated nuclear accident scenarios. The following points are the principal findings of the report. Given the prevailing wind direction in Ireland, radioactive contamination in the air, either from routine operation of the proposed nuclear power plants or accidental releases, will most often be transported away from Ireland. The routine operation of the proposed nuclear power plants will have no measurable radiological impact on Ireland or the Irish marine environment. The severe accident scenarios assessed ranged in their estimated frequency of occurrance from 1 in 50,000 to 1 in 33 million per year. The assessment used a weather pattern that maximised the transfer of radioactivity to Ireland. For the severe accident scenarios assessed, food controls or agriculture protective measures would generally be required in Ireland to reduce exposure of the population so as to mitigate potential long-term health effects. In the accident scenario with an estimated 1 in 33 million chance of occurring, short-term measures such as staying indoors would also be advised as a precautionary measure. In general, the accidents with higher potential impact on Ireland are the ones least likely to occur. Regardless of the radiological impact, any accident at the proposed nuclear power plants leading to an increase of radioactivity levels in Ireland would have a socio-economic impact on Ireland. A major accidental release of radioactivity to

  11. Proposed Nuclear Power Plants in the UK-Potential Radiological Implications for Ireland

    Energy Technology Data Exchange (ETDEWEB)

    McMahon, C.; Kelleher, K.; McGinnity, P.; Organo, C.; Smith, K.; Currivan, L.; Ryan, T.

    2013-05-15

    The UK Government has identified up to eight locations for the construction of new nuclear power plants by 2025. Five of these locations are on the Irish Sea coast. The Radiological Protection Institute of Ireland, RPII was requested by the Minister for the Environment, Community and Local Government to undertake an assessment of the potential radiological impacts on Ireland from this New Build Programme. This report presents the findings of the potential impacts on Ireland of both the anticipated routine radioactive discharges and of a range of postulated nuclear accident scenarios. The following points are the principal findings of the report. Given the prevailing wind direction in Ireland, radioactive contamination in the air, either from routine operation of the proposed nuclear power plants or accidental releases, will most often be transported away from Ireland. The routine operation of the proposed nuclear power plants will have no measurable radiological impact on Ireland or the Irish marine environment. The severe accident scenarios assessed ranged in their estimated frequency of occurrance from 1 in 50,000 to 1 in 33 million per year. The assessment used a weather pattern that maximised the transfer of radioactivity to Ireland. For the severe accident scenarios assessed, food controls or agriculture protective measures would generally be required in Ireland to reduce exposure of the population so as to mitigate potential long-term health effects. In the accident scenario with an estimated 1 in 33 million chance of occurring, short-term measures such as staying indoors would also be advised as a precautionary measure. In general, the accidents with higher potential impact on Ireland are the ones least likely to occur. Regardless of the radiological impact, any accident at the proposed nuclear power plants leading to an increase of radioactivity levels in Ireland would have a socio-economic impact on Ireland. A major accidental release of radioactivity to

  12. 100 classic papers of interventional radiology: A citation analysis.

    Science.gov (United States)

    Crockett, Matthew T; Browne, Ronan Fj; MacMahon, Peter J; Lawler, Leo

    2015-04-28

    To define the 100 citation classic papers of interventional radiology. Using the database of Journal Citation Reports the 40 highest impact factor radiology journals were chosen. From these journals the 100 most cited interventional radiology papers were chosen and analysed. The top paper received 2497 citations and the 100(th) paper 200 citations. The average number of citations was 320. Dates of publication ranged from 1953 - 2005. Most papers originated in the United States (n = 67) followed by Italy (n = 20) and France (n = 10). Harvard University (n = 18) and Osped Civile (n = 11) were the most prolific institutions. Ten journals produced all of the top 100 papers with "Radiology" and "AJR" making up the majority. SN Goldberg and T Livraghi were the most prolific authors. Nearly two thirds of the papers (n = 61) were published after 1990. This analysis identifies many of the landmark interventional radiology papers and provides a fascinating insight into the changing discourse within the field. It also identifies topics, authors and institutions which have impacted greatly on the specialty.

  13. A preliminary assessment of the radiological impact of the Chernobyl reactor accident on the population of the European Community

    International Nuclear Information System (INIS)

    Morrey, M.; Brown, J.; Williams, J.A.; Crick, M.J.; Simmonds, J.R.; Hill, M.D.

    1988-01-01

    Following the Chernobyl accident the Commission of the European Communities asked the National Radiological Protection Board to carry out a preliminary assessment of the radiological consequences of the accident on the population of the European Community (EC). The aim of the study was to review information on the environmental contamination measured in member states of the EC; to make a preliminary assessment of individual and population doses for each country; to make an estimate of the resulting health impact and to indicate the effects of the various countermeasures taken by member states in terms of the reductions in both individual and population exposure which they produced. All of the main pathways by which people have been and will be exposed to radiation as a result of the accident were included in the assessment. The impact estimate is based on environmental measurements made during the month after the accident, and on calculations made using mathematical models of radionuclide transfer through the environment. The calculated effective doses to average individuals in EC countries from exposure over the next 50 years range from 0.3 μSv (in Portugal) to between about 300 and 500 μSv (in the FRG, Italy and Greece). The total collective effective dose to the population of EC countries, integrated over all time, is estimated to be about 80 000 man Sv. This may be compared to the collective effective dose from natural background radiation of about 500 000 man Sv every year. In some countries, the restrictions placed on consumption of some foods are estimated to have been effective in reducing doses to the most exposed individuals; the reduction being up to about a factor of 2. The results presented in this paper should therefore be regarded as preliminary

  14. A virtual environment for simulation of radiological accidents

    International Nuclear Information System (INIS)

    Silva, Tadeu Augusto de Almeida; Farias, Oscar Luiz Monteiro de

    2013-01-01

    A virtual environment is a computer environment, representative of a subset of the real world, and where models of the real world entities, process and events are included in a virtual (three-dimensional) space. Virtual environments are ideal tools for simulation of certain critical processes, such as radiological accidents, where human beings or properties can suffer irreversible or long term damages. Radiological accidents are characterized by the significant exposure to radiation of specialized workers and general public. The early detection of a radiological accident and the determination of its possible extension are essential factors for the planning of prompt answers and emergency actions. This paper proposes the integration of georeferenced representation of the three-dimensional space and agent-based models, with the objective to construct virtual environments that have the capacity to simulate radiological accidents. The three-dimensional georeferenced representations of space candidates are: 1) the spatial representation of traditional geographical information systems (GIS); 2) the representation adopted by Google Maps®. Adding agents to these spatial representations allow us to simulate radiological accidents, quantify the doses received by members of the public, obtain a possible spatial distribution of people contaminated, estimate the number of contaminated individuals, estimate the impact on the health-network, estimate environmental impacts, generate exclusion zones, build alternative scenarios and train staff to deal with radiological accidents. (author)

  15. A virtual environment for simulation of radiological accidents

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Tadeu Augusto de Almeida, E-mail: tedsilva@ird.gov.br [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil); Farias, Oscar Luiz Monteiro de, E-mail: fariasol@eng.uerj.br [Universidade do Estado do Rio de Janeiro (UERJ), Rio de Janeiro, RJ (Brazil)

    2013-07-01

    A virtual environment is a computer environment, representative of a subset of the real world, and where models of the real world entities, process and events are included in a virtual (three-dimensional) space. Virtual environments are ideal tools for simulation of certain critical processes, such as radiological accidents, where human beings or properties can suffer irreversible or long term damages. Radiological accidents are characterized by the significant exposure to radiation of specialized workers and general public. The early detection of a radiological accident and the determination of its possible extension are essential factors for the planning of prompt answers and emergency actions. This paper proposes the integration of georeferenced representation of the three-dimensional space and agent-based models, with the objective to construct virtual environments that have the capacity to simulate radiological accidents. The three-dimensional georeferenced representations of space candidates are: 1) the spatial representation of traditional geographical information systems (GIS); 2) the representation adopted by Google Maps®. Adding agents to these spatial representations allow us to simulate radiological accidents, quantify the doses received by members of the public, obtain a possible spatial distribution of people contaminated, estimate the number of contaminated individuals, estimate the impact on the health-network, estimate environmental impacts, generate exclusion zones, build alternative scenarios and train staff to deal with radiological accidents. (author)

  16. Evaluation of critical pathways, radionuclides, and remedial measures for reducing the radiological dose to returning populations at a former nuclear test site

    Energy Technology Data Exchange (ETDEWEB)

    Robison, W. L., LLNL

    1997-11-01

    Bikini Island, the major residence island at Bikini Atoll, was contaminated with radioactive fallout as a result of the BRAVO test conducted on March 1, 1954. We have identified the critical radionuclides and supplied radiological data needed to develop dose estimates for all possible exposure pathways. These estimates show that the major dose to returning populations would result from ingestion of cesium-137 (137 Cs) in locally grown terrestrial foods where the predicted population average effective dose exceeds current federal guidelines. Consequently, we designed several long-term field experiments to develop and evaluate methods to reduce the 137 Cs content in locally grown foods.This paper gives a general outline of the remediation experiments with a more detailed description of a preferred combined option. Our comparative evaluation on various remedial methods show that the combined option--potassium treatment of the entire islands with limited excavation of soil in village an d housing areas--will be effective in reducing the dose to about 10% of pretreatment levels, and offers very significant benefits with respect to adverse environmental impacts as well as savings in overall costs, time, and required expert resources.

  17. Implementation of a Radiological Safety Coach program

    Energy Technology Data Exchange (ETDEWEB)

    Konzen, K.K. [Safe Sites of Colorado, Golden, CO (United States). Rocky Flats Environmental Technology Site; Langsted, J.M. [M.H. Chew and Associates, Golden, CO (United States)

    1998-02-01

    The Safe Sites of Colorado Radiological Safety program has implemented a Safety Coach position, responsible for mentoring workers and line management by providing effective on-the-job radiological skills training and explanation of the rational for radiological safety requirements. This position is significantly different from a traditional classroom instructor or a facility health physicist, and provides workers with a level of radiological safety guidance not routinely provided by typical training programs. Implementation of this position presents a challenge in providing effective instruction, requiring rapport with the radiological worker not typically developed in the routine radiological training environment. The value of this unique training is discussed in perspective with cost-savings through better radiological control. Measures of success were developed to quantify program performance and providing a realistic picture of the benefits of providing one-on-one or small group training. This paper provides a description of the unique features of the program, measures of success for the program, a formula for implementing this program at other facilities, and a strong argument for the success (or failure) of the program in a time of increased radiological safety emphasis and reduced radiological safety budgets.

  18. Implementation of a Radiological Safety Coach program

    International Nuclear Information System (INIS)

    Konzen, K.K.

    1998-01-01

    The Safe Sites of Colorado Radiological Safety program has implemented a Safety Coach position, responsible for mentoring workers and line management by providing effective on-the-job radiological skills training and explanation of the rational for radiological safety requirements. This position is significantly different from a traditional classroom instructor or a facility health physicist, and provides workers with a level of radiological safety guidance not routinely provided by typical training programs. Implementation of this position presents a challenge in providing effective instruction, requiring rapport with the radiological worker not typically developed in the routine radiological training environment. The value of this unique training is discussed in perspective with cost-savings through better radiological control. Measures of success were developed to quantify program performance and providing a realistic picture of the benefits of providing one-on-one or small group training. This paper provides a description of the unique features of the program, measures of success for the program, a formula for implementing this program at other facilities, and a strong argument for the success (or failure) of the program in a time of increased radiological safety emphasis and reduced radiological safety budgets

  19. The radiological impact of the normal rail transport of radioactive materials in the United Kingdom

    International Nuclear Information System (INIS)

    Mairs, J.H.

    1983-01-01

    Recently the NRPB, under contract to the Health and Safety Executive, and in association with the British Railways Board, has assessed the radiological impact of consignments transported on the British Rail system. The work has shown the radiation exposure of British Rail staff and of the public to be low. This paper identifies the types of radioactive materials transported by rail, outlines the methods used to assess the doses to persons exposed and presents the results of these assessments. (author)

  20. Radiological impact during the extraction, processing and use of phosphate minerals in Cuba

    International Nuclear Information System (INIS)

    Zerquera, Juan T.; Prendes Alonso, Miguel; Ramos Biltres, Odalys

    2008-01-01

    The use of phosphates for the production of fertilisers is a practice broadly diffused in the world. Their wide use is associated to the contribution of this material to formulation of Nk fertilisers. It is known in turn that phosphates have in their composition appreciable quantities of radioactive elements of natural origin. For this reason the use of phosphates in the composition of fertilizers can cause a radiological impact to both workers and public during all the phases of extraction and processing of phosphates, as well as during the production and application of these fertilizers. Finally the transfer of radionuclides contained in the fertilizers to the products of human consumption (vegetables, milk, meat) can produce an additional radiological impact on population. In Cuba there exist six locations of phosphoric rocks, located in the counties of Pinar del Rio, Havana, Matanzas, Sancti-Spiritus and Holguin. From these deposits there were studied the two ones which are in exploitation: 'La Pimienta' deposit, located in the West part of the country and 'Trinidad de Guedes' deposit, located in the Centre-West of Cuba. Paper shows the results obtained by the Center for Radiation Protection and Hygiene (CPHR) in the determination of radionuclides concentrations in collected in the sites samples. Based on these results and taking into account both the features of routine works carried out in the sites and the later use of collected mineral as fertilizer, doses to mining workers and to members of the public were estimated. Estimated doses are in the range 0.3 - 2.70 mSv per year for workers and in the range 1.3 - 17 μSv per year. (author)

  1. Radiological consequences of radioactive effluents

    International Nuclear Information System (INIS)

    Clarke, R.H.

    1979-01-01

    A study of the differential radiological impact of the nuclear fuel cycle with and without plutonium recycle is being undertaken jointly by the National Radiological Protection Board and the Commissariat a l'Energie Atomique (CEA). A summary is given of the development of the methodology detailed in their first report to the Commission of the European Communities (CEC) (NRPB/CEA, A methodology for evaluating the radiological consequences of radioactive effluents released in normal operations. Luxembourg, CEC Doc. V/3011/75 EN (1979)). The Collective Effective Dose Equivalent Commitment was used in an attempt to assess the total health detriment. The application of the methodology within particular member states of the European Community has been discussed at seminars. Sensitivity analysis can identify the more important parameters for improving the accuracy of the assessment. (UK)

  2. Comparison of toxicological and radiological aspects of K basins sludge

    International Nuclear Information System (INIS)

    RITTMANN, P.D.

    1999-01-01

    The composition of various K Basins sludge is evaluated for its toxicological and radiological impacts downwind from accidents. It is shown that the radiological risk evaluation guidelines are always more limiting than the toxicological risk evaluation guidelines

  3. Radiological criteria for the disposal of solid radioactive wastes

    International Nuclear Information System (INIS)

    Webb, G.A.M.

    1986-01-01

    Radioactive waste disposal is only one cause of exposure to ionizing radiation. Criteria for control should fit into the world-wide system for protection against radiation hazards, developed by the International Commission on Radiological Protection over the past 50 years. The system is simple and logically inevitable for any non-threshold pollutant. It consists of limits to protect individuals against unacceptable risks and a requirement to reduce the overall impact of the source causing the radiation to a level that is 'as low as reasonably achievable'. Particular aspects examined in this paper include the long timescales of concern and the role of comparisons with natural levels of radiation. The output of radiological assessment is an input to broader decisions on waste management, accommodating environmental pressures within political judgements. It is necessary to pursue the scientific analysis of waste disposal so that the results can be used as a firm foundation to confront, openly and honestly, the concerns of the public and of the politicians. (author)

  4. Modeling the Radiological Impact of Tritium in Sewage Sludge Being Used as Fertilizer

    International Nuclear Information System (INIS)

    Venter, A.; Smith, G.

    2005-01-01

    A study was undertaken to assess the radiological impact on humans via the foodchain resulting from the presence of tritium and C-14 in sewage sludge being used as fertilizer on agricultural land. The key endpoint of the assessment was the annual individual dose to an average member of potential critical groups. As part of the assessment, a model was developed to simulate the distribution of tritium between sewage sludge and effluent in the sewage treatment plant, the release of tritium upon sludge decomposition and subsequent uptake by plants and animals. The modeling assumptions, as well as key parameters and parameter values will be discussed in this paper

  5. The Emergency Radiological Monitoring and Analysis Division of the United States Federal Radiological Monitoring and Assessment Center

    International Nuclear Information System (INIS)

    Thome, D.J.

    2000-01-01

    The U.S. Federal Radiological Emergency Response Plan (FRERP) provides the framework for integrating the various Federal agencies responding to a major radiological emergency. The FRERP authorises the creation of the Federal Radiological Monitoring and Assessment Center (FRMAC), which is established to co-ordinate all Federal agencies involved in the monitoring and assessment of the off-site radiological conditions in support of the impacted States and the Lead Federal Agency (LFA). Within the FRMAC, the Monitoring and Analysis Division is responsible for co-ordinating all FRMAC assets involved in conducting a comprehensive program of environmental monitoring, sampling, radioanalysis, and quality assurance. This program includes: 1. Aerial Radiological Monitoring - Fixed-Wing and Helicopter; 2. Field Monitoring and Sampling; 3. Radioanalysis - Mobile and Fixed Laboratories; 4. Radiation Detection Instrumentation - Calibration and Maintenance; 5. Environmental Dosimetry; 6. Integrated program of Quality Assurance. To assure consistency, completeness, and the quality of the data produced, a methodology and procedures manual is being developed. This paper discusses the structure, assets, and operations of the FRMAC Monitoring and Analysis Division and the content and preparation of the manual. (author)

  6. Organizational decentralization in radiology.

    Science.gov (United States)

    Aas, I H Monrad

    2006-01-01

    At present, most hospitals have a department of radiology where images are captured and interpreted. Decentralization is the opposite of centralization and means 'away from the centre'. With a Picture Archiving and Communication System (PACS) and broadband communications, transmitting radiology images between sites will be far easier than before. Qualitative interviews of 26 resource persons were performed in Norway. There was a response rate of 90%. Decentralization of radiology interpretations seems less relevant than centralization, but several forms of decentralization have a role to play. The respondents mentioned several advantages, including exploitation of capacity and competence. They also mentioned several disadvantages, including splitting professional communities and reduced contact between radiologists and clinicians. With the new technology decentralization and centralization of image interpretation are important possibilities in organizational change. This will be important for the future of teleradiology.

  7. Establishing diagnostic reference levels in digital radiology

    International Nuclear Information System (INIS)

    Bana, Remy Wilson

    2016-04-01

    Medical application of radiation has gained wider study since diagnostic radiology plays a very important role in modern medicine. The need of the service seems to increase since the invention of digital radiology as a new technology that promises greater accuracy while minimizing patient dose. However, it is not exempted in the harmonization of doses delivered to the patient undergoing same radiologic examination in different institutions either regional or nationwide. The objective of this project was to review the establishment of Diagnostic Reference Levels (DRLs) in digital radiology at National level with the aim to reduce patient dose while maintaining appropriate image quality. A general discussion on digital radiology has been presented focusing on the optimization of patient dose as well as dosimetric quantities used for the establishment of DRLs. Recommendations have been provided for Rwanda to initiate steps to establish National Diagnostic Reference Levels for common procedures in digital radiology. (au)

  8. Radiological impact of airborne effluents of coal-fired and nuclear power plants

    International Nuclear Information System (INIS)

    McBride, J.P.; Moore, R.E.; Witherspoon, J.P.; Blanco, R.E.

    1977-06-01

    Radiological impact of naturally occurring radionuclides in airborne effluents of a model coal-fired steam plant is evaluated assuming a release to the atmosphere of 1 percent of the ash in the coal burned and compared with the impact of radioactive materials in the airborne effluents of model light-water reactors. The principal exposure pathway for radioactive materials released from both types of plants is ingestion of contaminated foodstuffs. For nuclear plants immersion in the airborne effluents is also a significant factor in the dose commitment. Assuming that the coal burned contains 1 ppM uranium and 2 ppM thorium together with their decay products and using the same impact analysis methods used in evaluating nuclear facilities, the maximum individual dose commitments from the coal plant for the whole body and most organs (except the thyroid) are shown to be greater than those from a pressurized-water reactor (PWR) and, with the exception of the bone and kidney doses, less than those from a boiling-water reactor (BWR). With the exception of the bone dose, the maximum individual dose commitments from the coal plant are less than the numerical design guideline limits listed for light-water reactors (LWRs). Population dose commitments from the coal plant are higher than those from either nuclear plant

  9. Development of national level preparedness for response to nuclear and radiological emergencies

    International Nuclear Information System (INIS)

    Pradeepkumar, K.S.

    2014-01-01

    In India, DAE being the nodal agency for technical support for response to any radiation emergency nuclear disaster and various nuclear and radiological emergency scenarios and their impacts are identified. To reduce their consequences development of methodologies for detection and quick impact assessment, trained First Responders and Quick Response Teams (QRTs), twenty two DAE Emergency Response Centers, mobile and aerial radiation monitoring systems, aerial and ground based validation trials etc. are carried out. Study related to radiological threats and simulated RDD experiments conducted using stable isotopes indicates that radiation levels for distances more than 50 m will not be very high as hotspots may be restricted to nearby area. The biggest challenge from an RDD explosion will be handling of the radioactive contamination and 'fear factor' compared to radiation exposure to public or First Responders. Level and pattern of radioactive contamination on ground following releases during nuclear accidents and minimum strength of orphan radioactive sources to be detected are taken into account for optimizing systems and monitoring methodology required for emergency preparedness

  10. Radiochemical characterization and environmental radiological impact in tin and lead processing from cassiterite

    International Nuclear Information System (INIS)

    Garcia, Marcia Aparecida Antico

    2009-01-01

    The tin and lead industry located in Pirapora do Bom Jesus in the state of Sao Paulo, Brazil, is responsible for the production of about 7000 ton year-1 of tin and 350 ton year-1 of lead. The raw material used in this facility is cassiterite, which presents in its composition concentrations of natural radionuclides from the uranium and thorium series up to 660 kBq kg -1 and 450 kBq kg -1 , respectively. The smelting and refining processes may lead to concentrations of these radionuclides, mainly in the precipitated dust and in slag. In the operational process, intermediate refining and final slag are obtained and are stored in piles in open air. It is estimated that the amount of waste stored is about 600000 ton. This work aims to study the environmental radiological impact of the operation of this facility and to establish its Environmental Radiological Monitoring Program. In order to accomplish this task the content of radioactivity was determined in the raw material, products, byproducts, residue, deposition pond and exhausting systems. Although in the raw material the radionuclides from the uranium and thorium series are almost in equilibrium, during the processing this equilibrium is disrupted and the radionuclides migrate according to their chemical properties. Concentrations up to 31 kBq kg -1 for 238 U, 69 kBq kg -1 for 226 Ra, 2.5 kBq kg -1 for 210 Pb, 130 kBq kg -1 for 232 Th and 120 kBq kg -1 for 228 Ra were obtained in the slag. The environmental radiological impact was established by measuring the radionuclides in the critical compartments that is the ones that may cause exposure to the public. If the residue pile is considered, the critical pathways are the internal exposition from the dust inhalation and the water ingestion, due to re suspension and dispersion of the pile dust and groundwater contamination, respectively; and external exposure due to immersion in the radioactive cloud and soil contamination. For the emission of gaseous and particulate

  11. A Lean Six Sigma journey in radiology.

    Science.gov (United States)

    Bucci, Ronald V; Musitano, Anne

    2011-01-01

    The department of radiology at Akron Children's Hospital embarked on a Lean Six Sigma mission as part of a hospital wide initiative to show increased customer satisfaction, reduce employee dissatisfaction and frustration, and decrease costs. Three processes that were addressed were reducing the MRI scheduling back-log, reconciling discrepancies in billing radiology procedures, and implementing a daily management system. Keys to success is that managers provide opportunities to openly communicate between department sections to break down barriers. Executive leaders must be engaged in Lean Six Sigma for the company to be successful.

  12. Open Access Journal Policies: A Systematic Analysis of Radiology Journals.

    Science.gov (United States)

    Narayan, Anand; Lobner, Katie; Fritz, Jan

    2018-02-01

    The open access movement has pushed for greater access to scientific knowledge by expanding access to scientific journal articles. There is limited information about the extent to which open access policies have been adopted by radiology journals. We performed a systematic analysis to ascertain the proportion of radiology journals with open access options. A search was performed with the assistance of a clinical informationist. Full and mixed English-language diagnostic and interventional radiology Web of Science journals (impact factors > 1.0) were included. Nuclear medicine, radiation oncology, physics, and solicitation-only journals were excluded. Primary outcome was open access option (yes or no) with additional outcomes including presence or absence of embargo, complete or partial copyright transfer, publication fees, and self-archiving policies. Secondary outcomes included journal citations, journal impact factors, immediacy, Eigenfactor, and article influence scores. Independent double readings were performed with differences resolved by consensus, supplemented by contacting editorial staff at each journal. In all, 125 journals were identified; review yielded 49 journals (39%, mean impact factor of 2.61). Thirty-six of the journals had open access options (73.4%), and four journals were exclusively open access (8.2%). Twelve-month embargoes were most commonly cited (90.6%) with 28.6% of journals stating that they did not require a complete transfer of copyright. Prices for open access options ranged from $750 to $4,000 (median $3,000). No statistically significant differences were found in journal impact measures comparing journals with open access options to journals without open access options. Diagnostic and interventional radiology journals have widely adopted open access options with a few radiology journals being exclusively open access. Copyright © 2017 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  13. The choice of cement for the manufacture of concrete to be activated: the potential for reducing the radiological consequences of reactor decommissioning

    International Nuclear Information System (INIS)

    Woollam, P.B.

    1985-05-01

    This report presents trace element analyses of some candidate cements which might be used in the manufacture of Sizewell 'B' concrete. It completes a programme of work whose aim was to investigate the potential for reducing the radiological consequences of reactor decommissioning through selection of construction materials for activated components. In particular, consideration has been given to the potential for reducing the concentration of elements known to activate to long lived daughters. (U.K.)

  14. Routine Radiological Environmental Monitoring Plan

    International Nuclear Information System (INIS)

    Bechtel Nevada

    1998-01-01

    The U.S. Department of Energy manages the Nevada Test Site in a manner that meets evolving DOE Missions and responds to the concerns of affected and interested individuals and agencies. This Routine Radiological Monitoring Plan addressess complicance with DOE Orders 5400.1 and 5400.5 and other drivers requiring routine effluent monitoring and environmental surveillance on the Nevada Test Site. This monitoring plan, prepared in 1998, addresses the activities conducted onsite NTS under the Final Environmental Impact Statement and Record of Decision. This radiological monitoring plan, prepared on behalf of the Nevada Test Site Landlord, brings together sitewide environmental surveillance; site-specific effluent monitoring; and operational monitoring conducted by various missions, programs, and projects on the NTS. The plan provides an approach to identifying and conducting routine radiological monitoring at the NTS, based on integrated technical, scientific, and regulatory complicance data needs

  15. Radiology today

    International Nuclear Information System (INIS)

    Donner, M.W.; Heuck, F.H.W.

    1981-01-01

    The book encompasses the proceedings of a postgraduate course held in Salzburg in June 1980. 230 radiologists from 17 countries discussed here the important and practical advances of diagnostic radiology, nuclear medicine and ultrasound as they contribute to gastrointestinal, urologic, skeletal, cardiovascular, pediatric, and neuroradiology. The book contains 55 single contributions of different authors to the following main themes: Cardiovascular, Radiology, pulmonary radiology, gastrointestinal radiology, urinary tract radiology, skeletal radiology, mammography, lymphography, ultrasound, ENT radiology, and neuroradiology. (orig./MG)

  16. Radiologic image compression -- A review

    International Nuclear Information System (INIS)

    Wong, S.; Huang, H.K.; Zaremba, L.; Gooden, D.

    1995-01-01

    The objective of radiologic image compression is to reduce the data volume of and to achieve a lot bit rate in the digital representation of radiologic images without perceived loss of image quality. However, the demand for transmission bandwidth and storage space in the digital radiology environment, especially picture archiving and communication systems (PACS) and teleradiology, and the proliferating use of various imaging modalities, such as magnetic resonance imaging, computed tomography, ultrasonography, nuclear medicine, computed radiography, and digital subtraction angiography, continue to outstrip the capabilities of existing technologies. The availability of lossy coding techniques for clinical diagnoses further implicates many complex legal and regulatory issues. This paper reviews the recent progress of lossless and lossy radiologic image compression and presents the legal challenges of using lossy compression of medical records. To do so, the authors first describe the fundamental concepts of radiologic imaging and digitization. Then, the authors examine current compression technology in the field of medical imaging and discuss important regulatory policies and legal questions facing the use of compression in this field. The authors conclude with a summary of future challenges and research directions. 170 refs

  17. Potential radiological impact assessment related to the visit of nuclear submarines to the port of Rio de Janeiro, Brazil

    International Nuclear Information System (INIS)

    Pereira, Jose Francisco; Rochedo, Elaine R.R.

    2005-01-01

    Brazil is signatory of international protocols for receiving the visit of nuclear ships and submarines. Such naval units, during their stays in Brazilian ports, inform that there is no release of radioactive material to the environment. However, there is always the possibility of an accident, leading to environmental release of radioactive material. This work had the objective of assessing the potential radiological environmental impact due to the eventual occurrence of an accident during the permanence of ships and submarines of nuclear propulsion in the port of the city of Rio de Janeiro, in Guanabara Bay. The accident scenarios considered include releases to the marine environment and to the atmosphere. Previous results indicated that, in normal operation conditions, no significant radiological impact is foreseen due to the visits of nuclear submarines to the city, even if small routine radionuclide releases occur. The analysis of the accidental releases, however, indicates that the anchorage points should be located at a minimum distance of 2,5 km of inhabited areas in the contour the Bay. (author)

  18. Radiology standards for primary dental care: report by the Royal College of Radiologists and the National Radiological Protection Board

    International Nuclear Information System (INIS)

    Hudson, Tony

    1994-01-01

    In 1992 a joint venture between the Royal College of Radiologists (RCR) and the National Radiological Protection Board (NRPB) resulted in the formation of a Working Party (WP) to consider dental radiology. Although individual doses to patients are low, WP identified considerable scope for reducing the collective dose to patients and for improving the diagnostic quality of radiographs. The report published in the Documents of the NRPB series presents the WP conclusions in the form of guidelines that deal with all aspects of dental radiology in primary dental care. (Author)

  19. Challenges in radiological impact assessment studies at new sites for nuclear facilities and its safety review and assessment for siting consent

    International Nuclear Information System (INIS)

    Mukherjee Roy, Susmita; Roshan, A.D.; Bishnoi, L.R.

    2018-01-01

    One of the basic requirement of site evaluation for a Nuclear Facility (NF) is radiological impact assessment (RIA). This involves evaluation of transportation of radioactive materials discharged from a nuclear facility under normal operational or accidental conditions, through different compartments of environment viz. air, land and water, and finally assessment of its consequences. Amongst others, site characteristics and the site related parameters play major role in evaluation of impact of postulated releases from NPPs. Doses to public from both external and internal exposures are computed to assess potential consequences of a radiological release and acceptability of the site-plant pair is established based on the outcome of this assessment. A comprehensive study of the site characteristics including meteorology, hydrology, hydro-geology and demography of the region along with details of land and water use, bioaccumulation, transfer to and from the environmental matrices is required for accomplishing satisfactory RIA

  20. Radiological emergencies the first response

    International Nuclear Information System (INIS)

    2011-11-01

    This national training course about radiological emergencies first answer include: Targets and preparation for emergency response in case of a nuclear or radiological accident. Operations center, action guide for fire fighting, medical coverage, forensic test, first aid, basic instrumentation for radiation, safety equipment, monitoring radiation, gamma rays, personnel exposed protection , radiation exposure rate, injury and illness for radiation, cancer risk, contamination, decontamination and treatment, markers, personnel dosimetry, training, medical and equipment transportation, shielded and tools. Psychological, physical (health and illness), economical (agriculture and industry) and environment impacts. Terrorist attacks, security belts. Support and international agreements (IAEA)

  1. Radiology journals in transition: a summary of the 2013 Intersociety Committee Summer Conference.

    Science.gov (United States)

    Dodd, Gerald D

    2015-01-01

    The digital and online revolution is having a profound impact on radiology journals, forcing a migration from print to online publication and altering traditional revenue streams needed to sustain the journals. The 2013 Intersociety Committee Summer Conference attendees reviewed the history of the development of radiology journals, explored the forces driving the transition from print to electronic publication, and examined the impact of the alteration of the traditional revenue streams, such as subscription and advertisement dollars, on the financial sustainability of journals. The attendees also discussed the international movement toward open access to journal content and its impact on a journal's financial viability. Lastly, the committee explored the perceived value of radiology journals based on readership type: academic, private practice, or industry. Copyright © 2015 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  2. Integrative teaching in radiology - a survey.

    Science.gov (United States)

    Dettmer, S; Weidemann, J; Fischer, V; Wacker, F K

    2015-04-01

    To survey integrative teaching in radiology at German universities. A questionnaire about radiological education was sent electronically to all 37 chairpersons of university radiology departments in Germany. The questions included the course type, teaching methods, concept, perception, and advantages and disadvantages of integrative teaching. Statistical analysis was performed with nonparametric statistics and chi-square test. The survey was considered representative with a return rate of 68 %. Integrative teaching is established at 4/5 of all departments. Integrative teaching is well accepted with an acceptance rate that is significantly higher in so-called "Modellstudiengängen" [model courses of study] (100 %) compared to conventional courses of study (72 %). The advantages of integrative teaching include linking of content (92 %) and preparation for interdisciplinary work (76 %). The disadvantages include high effort (75 %) and time (67 %) for organization. Furthermore, there is a risk that basic radiological facts and knowledge cannot be conveyed and that the visibility of radiology as an independent discipline is lost. Conventional radiological teaching has a similarly high acceptance (84 %) compared to integrative courses (76 %). Integrative teaching has a high acceptance among chairpersons in radiology in Germany despite the greater effort. A good interdisciplinary collaboration is essential for integrative teaching and at the same time this can be conveyed to the students. However, the visibility of radiology as a discipline and the possibility to cover basic radiological content must be ensured. Therefore, both conventional courses and integrative teaching seems reasonable, especially in cross-disciplinary subjects such as radiology. Both integrative teaching and conventional radiological teaching are highly accepted. The advantages include the linking of multidisciplinary content and the preparation for interdisciplinary cooperation

  3. Qualitative evaluation of environmental radiological impact in a phosphate associated uranium conventional mine: Santa Quiteria Project, CE, Brazil

    International Nuclear Information System (INIS)

    Reis, Rocio G. dos; Santo, Aline Sa E.

    2013-01-01

    The aim of this study is to identify and evaluate qualitatively the main potential sources of mineral and installation terms of Santa Quiteria, CE, Brazil, evaluating their possible impacts on the environment. The key terms sources in the production of phosphoric acid are usually: the dig of the mines, tailings dams and phospho plaster stack. Thus, this work intends to inform the academic community about this issue, as well as the population in general and also, acting proactively in order to warn about the possible environmental impacts, so that actions to compensate, minimize or avoid these radiological impacts on the environment, can be included in the planning of the industrial mineral project of Santa Quiteria (author)

  4. Radiological impacts of transporting Three Mile Island core debris

    International Nuclear Information System (INIS)

    Cox, N.D.

    1986-01-01

    This document presents an assessment of the radiological impacts of one cask shipment. It focuses on potential effects of the shipment on the public along the route. The document begins with a description of the shipping cask, followed by a description of the survivability tests required to confirm the cask design. Some actual accidents that similar casks have survived wholly intact are described. Next considered is the limit of radiation exposure dose rate that is imposed by regulatory agencies under normal conditions. No shipping of radioactive material is allowed unless the container is at or below the normal limit. A comparison is made between the normal radiation exposure limit and the radiation dose received annually by individuals from natural sources. Then, estimates of the radiation dose received by persons along the rail route in urban, suburban, and rural areas during normal transport are presented. Those times when the train stops for whatever reason (called rest stops) are considered also. Next, potential accident events are considered. Recent accident statistics are presented, and chances for an accident at different train velocities are estimated for any mile of track. The alternative of truck transport is considered briefly

  5. Assessment of management alternatives for LWR wastes. Volume 5. Assessment of the radiological impact to the public resulting from discharges of radioactive effluents

    International Nuclear Information System (INIS)

    Centner, B.

    1993-01-01

    This report deals with the assessment of the radiological impact to the public resulting from discharges of radioactive effluents (liquid and gaseous) in connection with the implementation of the Belgian scenario for the management of PWR waste. Both individual and collective doses have been estimated for a critical group of the population living around the nuclear power plants concerned. This study is part of an overall theoretical exercise aimed at evaluating a selection of management wastes for LWR waste based on economical and radiological criteria

  6. Reducing the global threat of radiological terrorism in Central Asia and Caucus regions. The global threat reduction initiative approach to radioactive source security

    International Nuclear Information System (INIS)

    Smith, E.

    2010-01-01

    The security of radioactive sources is of worldwide concern, due to their wide use in civilian commerce and the potentially devastating effects of their misuse. In cooperation with host countries and international partners, the Global Threat Reduction Initiative has utilized a proven process for providing technical and financial assistance to protect radioactive sources in diverse uses and unique circumstances at hundreds of sites worldwide. The mission of the Department of Energy, National Nuclear Security Administration's program includes reducing the risk posed by vulnerable radiological materials that could be used in a Radioactive Dispersal Device). The program's objectives are to identify, consolidate, secure, and/or dispose of high-activity radiological materials to prevent their theft and malicious use. The Global Threat Reduction Initiative Program's scope is global, with projects in over 100 countries at more than 755 radiological sites, including industrial, medical and commercial facilities. In addition to working bilaterally, the Program works closely with the International Atomic Energy Agency (IAEA) and other partner countries. (author)

  7. Radiological impact from the transport of radiopharmaceuticals of the IPEN/CNEN-SP

    International Nuclear Information System (INIS)

    Rodrigues, Demerval Leonidas

    2009-01-01

    When a package is shipped, people who work, live or travel in the route used for transportation of radioactive materials are irradiated, as well as those who are inside vehicles that travel in the same or opposite directions. Therefore, the proposed work has as main objective to estimate the radiological impact of the transportation of radiopharmaceuticals of IPEN/CNEN-SP to some predefined destinations. The doses in individuals who are in the public streets and in vehicles that travel close to the means of transportation, along the route traveled by packages, during the transport of radiopharmaceuticals were estimated. The doses were also estimated for drivers, from both the operation of driving the vehicle, and the loading and unloading of packages, because these tasks are performed by the drivers. (author)

  8. Pediatric radiology for medical-technical radiology assistants/radiologists

    International Nuclear Information System (INIS)

    Oppelt, Birgit

    2010-01-01

    The book on pediatric radiology includes the following chapter: differences between adults and children; psycho-social aspects concerning the patient child in radiology; relevant radiation doses in radiology; help for self-help: simple phantoms for image quality estimation in pediatric radiology; general information; immobilization of the patient; pediatric features for radiological settings; traumatology; contrast agents; biomedical radiography; computerized tomography; NMR imaging; diagnostic ultrasonography; handling of stress practical recommendations; medical displays.

  9. Responding to nuclear terrorism. Chapter 3. Combating radiological terrorism - A multi-faceted challenge

    International Nuclear Information System (INIS)

    Wolf, A.; Yaar, I.

    2006-01-01

    In the twentieth century, radioactive sources have become extensively used in everyday life. These sources, in the hand of terror organizations, can become a threat to the security of civilized nations, causing severe disruption to normal life. On of the main challenges of the civilized world is to keep ahead of the terrorist organizations and take appropriate preventive measures in order to prevent and reduce to minimum the impact of their actions. In order to succeed, a joint and comprehensive effort has to be undertaken to address the scientific, technological, organizational, sociological, psychological and educational aspects of the radiological terrorism threat. In this paper, some of the main activities required for preventing radiological terror events, and the way in which a modular response plan can be prepared are discussed

  10. 100 classic papers of interventional radiology: A citation analysis

    Science.gov (United States)

    Crockett, Matthew T; Browne, Ronan FJ; MacMahon, Peter J; Lawler, Leo

    2015-01-01

    AIM: To define the 100 citation classic papers of interventional radiology. METHODS: Using the database of Journal Citation Reports the 40 highest impact factor radiology journals were chosen. From these journals the 100 most cited interventional radiology papers were chosen and analysed. RESULTS: The top paper received 2497 citations and the 100th paper 200 citations. The average number of citations was 320. Dates of publication ranged from 1953 - 2005. Most papers originated in the United States (n = 67) followed by Italy (n = 20) and France (n = 10). Harvard University (n = 18) and Osped Civile (n = 11) were the most prolific institutions. Ten journals produced all of the top 100 papers with “Radiology” and “AJR” making up the majority. SN Goldberg and T Livraghi were the most prolific authors. Nearly two thirds of the papers (n = 61) were published after 1990. CONCLUSION: This analysis identifies many of the landmark interventional radiology papers and provides a fascinating insight into the changing discourse within the field. It also identifies topics, authors and institutions which have impacted greatly on the specialty. PMID:25918585

  11. Description of the operation and radiological impact of a spanish coastal coal-fired power station

    International Nuclear Information System (INIS)

    Corbacho, Jose A.; Baeza, Antonio; Robles, Beatriz; Mora, Juan C.; Cancio, David

    2008-01-01

    The 'Litoral' Coal-Fired Power Plant (LCFPP) is situated in the town of Carboneras (Almeria) in southern Spain. Its nominal output power is 1589 M We. The fuel used is imported sub-bituminous coal supplied by collier vessels, and unloaded in a port annexed to the plant. The climate of the area is semi-arid mediterranean, with particularly low rainfall. The plant's radiological impact was studied considering various exposure pathways for the workers and the general public. In particular, inhalation and external exposure contributions to the effective dose due to the different materials involved in the operation (coals, fly ash, and bottom ash) were evaluated. Alpha spectrometry was used to characterize radiologically the airborne particulates collected in aerosol filters at points within the installation, and to determine 210 Po levels in aerosols collected in filters placed around the power station. High resolution gamma spectrometry was used to characterize coal and ash samples from the plant, and soil samples collected outside the installation within a radius of 5 km. A dose rate monitor was used to measure the ambient dose equivalent at different points inside and outside the plant. Samples of the seawater used in the plant and of products for human consumption produced nearby were also collected and characterized radiologically. The effective dose was evaluated following a realistic approach based principally on experimental measurements and in situ observations, complemented with mathematical models when necessary. The resulting estimated effective doses for selected representative groups of workers and general public were all below the reference levels used in this work. (author)

  12. Environmental Radiological Impact of Nuclear Power. Monitoring and Control Programs

    International Nuclear Information System (INIS)

    Ramos, L. M.

    2000-01-01

    Radioactive contamination of the environment and public exposure to ionizing radiation may result from releases from programmed or accidental operations in regulated activities, or they may be due to preexisting situations such as contamination caused by past accidents, radioactive rain caused by nuclear tests, or increased natural radioactivity resulting from human activities. In many cases, both the emission sources and the environment should be monitored to determine the risk to the population and verify to what extent the limits and conditions established by competent authorities are being observed. Monitoring can be divided into three categories: monitoring of the emission source, of the receiving medium and of members of the public; individual monitoring of the population is extremely rare and would only be considered when estimated doses substantially exceed the annual public dose limit. In practices likely to produce significant radioactive releases, as is the case of nuclear fuel cycle facilities, the limits and conditions for monitoring and controlling them and the requirements for environmental radiological monitoring are established in the licensing process. Programs implemented during normal operation of the facilities form the basis for monitoring in the event of accidents. in addition to environmental radiological monitoring associated with facilities, different countries have monitoring programs outside the facilities zones of influence, in order to ascertain the nationwide radiological fund and determine possible increases in this fund. In Spain, the facilities that generate radioactive waste have effluent storage, treatment and removal systems and radiological monitoring programs based on site and discharge characteristics. The environmental radiological monitoring system is composed of the network implemented by the owners in the nuclear fuel cycle facilities zones of influence, and by nationwide monitoring networks managed by the Consejo de

  13. Radiological impact assessment of arc welding supplies rutile; Evaluacion del impacto radiologico de la soldadura por arco con consumibles de rutilo

    Energy Technology Data Exchange (ETDEWEB)

    Rozas Guinea, S.; Herranz Soler, M.; Perez Marin, C.; Idoeta Hermandorena, R.; Alegria gutierrez, N.; Nunez-Lagos Rogla, R.; Legarda Ibanez, F.

    2013-07-01

    Consumables for welding containing rutile, the coating of the electrode or the filling of tubular thread, are the most widely used and also the most radioactive since the rutile is a mineral containing traces of natural radionuclides, and is therefore considered Normal Occurring Radioactive Material (NORM). As these electrodes and wire are consumed, small particles, aerosols and gases are emitted to the atmosphere of work, and may be inhaled by the welder. Therefore, and also according to the current regulatory framework and work carried out previously by the author on the radiological impact of the process of manufacture and storage of coated rutile electrodes, the objectives are: 1Calcular the internal dose for inhalation during two types of welding, one with electrodes coated and the other with thread. 2 calculate the external dose due to the deposition of particles in the work environment, slag and the immersion of the soldering iron in the cloud of smoke. 3 to assess the radiological impact. (Author)

  14. Deep Learning in Radiology.

    Science.gov (United States)

    McBee, Morgan P; Awan, Omer A; Colucci, Andrew T; Ghobadi, Comeron W; Kadom, Nadja; Kansagra, Akash P; Tridandapani, Srini; Auffermann, William F

    2018-03-29

    As radiology is inherently a data-driven specialty, it is especially conducive to utilizing data processing techniques. One such technique, deep learning (DL), has become a remarkably powerful tool for image processing in recent years. In this work, the Association of University Radiologists Radiology Research Alliance Task Force on Deep Learning provides an overview of DL for the radiologist. This article aims to present an overview of DL in a manner that is understandable to radiologists; to examine past, present, and future applications; as well as to evaluate how radiologists may benefit from this remarkable new tool. We describe several areas within radiology in which DL techniques are having the most significant impact: lesion or disease detection, classification, quantification, and segmentation. The legal and ethical hurdles to implementation are also discussed. By taking advantage of this powerful tool, radiologists can become increasingly more accurate in their interpretations with fewer errors and spend more time to focus on patient care. Copyright © 2018 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  15. User questionnaire to evaluate the radiological workspace

    NARCIS (Netherlands)

    van Ooijen, Peter M. A.; Koesoema, Allya P.; Oudkerk, Matthijs

    2006-01-01

    Over the past few years, an increase in digitalization of radiology departments can be seen, which has a large impact on the work of the radiologists. This impact is not only demonstrated by the increased use of digital images but also by changing demands on the whole reading environment. In this

  16. Evaluating variability and uncertainty in radiological impact assessment using SYMBIOSE

    International Nuclear Information System (INIS)

    Simon-Cornu, M.; Beaugelin-Seiller, K.; Boyer, P.; Calmon, P.; Garcia-Sanchez, L.; Mourlon, C.; Nicoulaud, V.; Sy, M.; Gonze, M.A.

    2015-01-01

    SYMBIOSE is a modelling platform that accounts for variability and uncertainty in radiological impact assessments, when simulating the environmental fate of radionuclides and assessing doses to human populations. The default database of SYMBIOSE is partly based on parameter values that are summarized within International Atomic Energy Agency (IAEA) documents. To characterize uncertainty on the transfer parameters, 331 Probability Distribution Functions (PDFs) were defined from the summary statistics provided within the IAEA documents (i.e. sample size, minimal and maximum values, arithmetic and geometric means, standard and geometric standard deviations) and are made available as spreadsheet files. The methods used to derive the PDFs without complete data sets, but merely the summary statistics, are presented. Then, a simple case-study illustrates the use of the database in a second-order Monte Carlo calculation, separating parametric uncertainty and inter-individual variability. - Highlights: • Parametric uncertainty in radioecology was derived from IAEA documents. • 331 Probability Distribution Functions were defined for transfer parameters. • Parametric uncertainty and inter-individual variability were propagated

  17. Potential clinical impact of advanced imaging and computer-aided diagnosis in chest radiology: importance of radiologist's role and successful observer study.

    Science.gov (United States)

    Li, Feng

    2015-07-01

    This review paper is based on our research experience in the past 30 years. The importance of radiologists' role is discussed in the development or evaluation of new medical images and of computer-aided detection (CAD) schemes in chest radiology. The four main topics include (1) introducing what diseases can be included in a research database for different imaging techniques or CAD systems and what imaging database can be built by radiologists, (2) understanding how radiologists' subjective judgment can be combined with technical objective features to improve CAD performance, (3) sharing our experience in the design of successful observer performance studies, and (4) finally, discussing whether the new images and CAD systems can improve radiologists' diagnostic ability in chest radiology. In conclusion, advanced imaging techniques and detection/classification of CAD systems have a potential clinical impact on improvement of radiologists' diagnostic ability, for both the detection and the differential diagnosis of various lung diseases, in chest radiology.

  18. Good practices in radiological protection at Narora Atomic Power Station

    International Nuclear Information System (INIS)

    Singh, V.P.; Kumar, Sanjeev; Agrawal, Mitesh; Tiwari, S.K.; Kulhari, Praveen; Gupta, Ashok

    2016-01-01

    Radiological protection performance of nuclear power plant is assessed by collective exposure, individual average exposure, external/external exposure, personnel/surface contamination and reduction of radioactive wastes. Collective exposure is reduced by integrated comprehensive ALARA program in all aspects of nuclear plant operation and maintenance has reduced collective dose many folds. In the present paper, implementation of new good practices in Radiological Protection is presented

  19. Radiological safety evaluation report for NUWAX-79 exercise

    International Nuclear Information System (INIS)

    King, W.C.

    1979-03-01

    An analysis of the radiological safety of the NUWAX-79 exercise to be conducted on the Nevada Test Site in April 1979 is given. An evaluation of the radiological safety to the participants is made using depleted uranium (D-38) in mock weapons parts, and 223 Ra and its daughters as a radioactive contaminant of equipment and terrain. The radiological impact to offsite persons is also discussed, particularly for people living at Lathrop Wells, Nevada, which is located 7 miles south of the site proposed for the exercise. It is the conclusion of this evaluation that the potential radiological risk of this exercise is very low, and that no individual should receive exposure to radioactivity greater than one-tenth of the level permitted under current federal radiation exposure guidelines

  20. Anticipated radiological impacts from the mining and milling of thorium for the nonproliferative fuels

    International Nuclear Information System (INIS)

    Meyer, H.R.; Till, J.E.

    1978-01-01

    Recent emphasis on proliferation-resistant fuel cycles utilizing thorium--uranium-233 fuels has necessitated evaluation of the potential radiological impact of mining and milling thorium ore. Therefore, an analysis has been completed of hypothetical mine-mill complexes using population and meteorological data representative of a thorium resource site in the Lemhi Pass area of Idaho/Montana, United States of America. Source terms for the site include thorium-232 decay chain radionuclides suspended as dusts and radon-220 and daughters initially released as gas. Fifty-year dose commitments to maximally exposed individuals of 2.4 mrem to total body, 9.5 mrem to bone, and 35 mrem to lungs are calculated to result from facility operation. Radium-228, thorium-228, thorium-232 and lead-212 (daughter of radon-220) are found to be the principal contributors to dose. General population doses for a 50-mile radius surrounding the facility are estimated to be 0.05 man-rem to total body, 0.1 man-rem to bone, and 0.7 man-rem to lungs. Generally speaking, the results of this study indicate that the radiological aspects of thorium mining and milling should pose no significant problems with regard to implementation of thorium fuel cycles

  1. Radiation Protection Research: Radiological Assessment

    International Nuclear Information System (INIS)

    Zeevaert, T.

    2000-01-01

    The objectives of SCK-CEN's research in the field of radiological impact assessment are (1) to elaborate and to improve methods and guidelines for the evaluation of restoration options for contaminated sites; (2) to develop, test and improve biosphere models for the performance assessment of radioactive waste disposal in near-surface or geological repositories; (3) to asses the impact of releases from nuclear or industrial installations. Main achievements in these areas for 2000 are summarised

  2. Environmental impacts of radiological consequences during the anticipated transients without scram (ATWS) events in nuclear power reactors

    International Nuclear Information System (INIS)

    El-Kafas, A.A.

    2011-01-01

    Anticipated transients without scram (ATWS), is one of the (worst case) accidents could happen if the system that provides a highly reliable means of shutting down the reactor (scram system )fails to work during a reactor event (anticipated transient).It has two general characteristics: (1) Initiation by a transient anticipated to occur one or more times in the life of reactor and ,(2) Assumed to proceed without scram.The types of events considered are those used for designing the plant .The evaluation of the radiological consequences during the assessment of the nuclear events,especially ATWS in nuclear power reactors, is very essential for environmental studies and public safety. In this paper, the root cases for nuclear events and dose calculation are presented. Scenario of accident sequences together with radiological impacts is illustrated for loss of coolant accident (LOCA) for a typical pressurized water reactor nuclear power plant. Recommendations for mitigating or preventing the release of radiation and high radioactive materials to environment are presented.

  3. Application of geographic information system for radiologic emergency response

    International Nuclear Information System (INIS)

    Best, R.G.; Doyle, J.F.; Mueller, P.G.

    1998-01-01

    Comprehensive and timely radiological, cultural, and environmental data are required in order to make informed decisions during a radiological emergency. Within the Federal Radiological Monitoring and Assessment Center (FRMAC), there is a continuing effort to improve the data management and communication process. The most recent addition to this essential function has been the development of the Field Analysis System for Emergency Response (FASER). It is an integrated system with compatible digital image processing and Geographic Information System (GIS) capabilities. FASER is configured with commercially available off-the-shelf hardware and software components. To demonstrate the potential of the FASER system for radiological emergency response, the system has been utilized in interagency FRMAC exercises to analyze the available spatial data to help determine the impact of a hypothetical radiological release and to develop mitigation plans. (R.P.)

  4. Radiological Worker Training: Radiological Worker 2 study guides

    International Nuclear Information System (INIS)

    1992-10-01

    Upon completion of this training course, the participant will have the knowledge to work safely in areas controlled for radiological purposes using proper radiological practices. Radiological Worker H Training, for the worker whose job assignment involves entry into Radiological Buffer Areas and all types of Radiation Contamination and Airborne Radioactivity Areas. This course is designed to prepare the worker to work safely in and around radiological areas and present methods to use to ensure individual radiation exposure is maintained As Low As Reasonably Achievable

  5. Assessment of radiological impact in mineral industrial plants caused by deposition of wastes with U238 and/or Th232 associated

    International Nuclear Information System (INIS)

    Ladeira, Paula C.; Alves, Rex Nazare; Ruperti Junior, Nerbe J.

    2011-01-01

    The industrial-mining facilities constantly produce, in Brazil and in abroad, wastes from its production, many times containing uranium and/or thorium associated. Due to the large quantities generated, these wastes are usually deposited at the site of the facility, close to the place where they were produced. Since the chains of radioactive U 238 and Th 232 with alpha-emitting radionuclides have long half-life, waste deposits associated with these elements may cause radiological impact on the man and on the environment, even in the long term. Mathematical models are often used to represent the biosphere and the transport of radionuclides near to the surface. Thus, it was decided, through the software M athematica , to present a methodology based on the solution of Bateman equations for the calculation of radiological impact on individuals from the public exposed to contamination. The radiological impact appraisal was carried out considering a scenario of intrusion into landfills containing U 238 and / or Th 232 in post-operational phase of an industrial-mining installation. The critical group examined was represented by farmers who used water from an artesian well for daily consumption and which feed themselves on vegetables locally grown in clay soil. As a result, there was the exposure in pathways evaluated, a minor contribution of dose for ingestion of contaminated water. The conclusion of this work, show us that calculated doses were within the accepted international limits for the intrusion scenario. Parameters associated with mathematical models defining the choice of project to build a landfill for the purpose of deposition, whereas rates of doses can be estimated in each of the scenarios proposed. (author)

  6. Evaluation of Stress and a Stress-Reduction Program Among Radiologic Technologists.

    Science.gov (United States)

    Reingold, Lynn

    2015-01-01

    To investigate stress levels and causes of stress among radiologic technologists and determine whether an intervention could reduce stress in a selected radiologic technologist population. Demographic characteristics and data on preintervention stress sources and levels were collected through Internet-based questionnaires. A 6-week, self-administered, mindfulness-based stress-reduction program was conducted as a pilot intervention with 42 radiologic technologists from the Veterans Administration Medical Center. Data also were collected postintervention. Identified sources of stress were compared with findings from previous studies. Some radiologic technologists experienced improvement in their perceptions of stress after the intervention. Sources of stress for radiologic technologists were similar to those shown in earlier research, including inconsistent management, poor management communication, conflicting demands, long work hours, excessive workloads, lack of work breaks, and time pressures. The mindfulness-based stress-reduction program is an example of an inexpensive method that could improve personal well-being, reduce work errors, improve relationships in the workplace, and increase job satisfaction. More research is needed to determine the best type of intervention for stress reduction in a larger radiologic technologist population.

  7. [Regulating radiological protection and the role of health authorities].

    Science.gov (United States)

    Arias, César F

    2006-01-01

    This article summarizes the development of protection against ionizing radiation and explains current thinking in the field. It also looks at the decisive role that regulatory agencies for radiological protection must play and the important contributions that can be made by health authorities. The latter should take an active part in at least three aspects: the formal education of health personnel regarding radiological protection; the medical care of individuals who are accidentally overexposed, and the radiological protection of patients undergoing radiological procedures. To this end, health professionals must possess sufficient knowledge about radiological protection, promote the use of proper equipment, and apply the necessary quality assurance procedures. Through their effective intervention, national health authorities can greatly contribute to reducing unnecessary doses of radiation during medical procedures involving radiation sources and decrease the chances that radiological accidents will take place.

  8. Nuclear and energies nr 57. Japan, another glance. The environmental and radiological impact. The international impact. The illusion of renewable energies in Japan

    International Nuclear Information System (INIS)

    Lenail, B.

    2011-07-01

    The contributions of this publication first address the Japanese local context (organization, mentality, cultural background, thinking and action modes), and secondly the environmental and radiological impact of the Fukushima accident, notably in comparison with Chernobyl (contamination is much more localized, sometimes higher; a larger concerned population but quicker and more efficient protection measures; more severe consequences due to population displacement). The third article discusses the international impact of the accident: known or foreseen consequences on nuclear programs, discussion on safety strengthening and on governance, evolution of public opinion, possible consequences on climate negotiations. The last article proposes an overview of the current situation of Japan which must mobilize all the available energy resources to face the difficulties in electricity supply

  9. Diagnostic radiology 1987

    International Nuclear Information System (INIS)

    Margulis, A.R.; Gooding, C.A.

    1987-01-01

    This is the latest version of the continuing education course on diagnostic radiology given yearly by the Department of Radiology at the University of California, San Francisco. The lectures are grouped into sections on gastrointestinal radiology, mammography, uroradiology, magnetic resonance, hepatobiliary radiology, pediatric radiology, ultrasound, interventional radiology, chest radiology, nuclear medicine, cardiovascular radiology, and skeletal radiology. Each section contains four to eight topics. Each of these consists of text that represents highlights in narrative form, selected illustrations, and a short bibliography. The presentation gives a general idea of what points were made in the lecture

  10. Training Workers to use Localized Ventilation for Radiological Work

    International Nuclear Information System (INIS)

    WAGGONER, L.O.

    2000-01-01

    Work on radiological systems and components needs to be accomplished using techniques that reduce radiation dose to workers, limit contamination spread, and minimize radioactive waste. One of the best methods to control contamination spread is to use localized ventilation to capture radioactive material and keep it from spreading. The Fluor Hanford ALARA Center teaches workers how to use ventilation in partnership with other engineered controls and this has resulted in improved work practices, minimized the impact on adjacent work operations, and decreased the amount of radioactive waste generated. This presentation will emphasize how the workers are trained to use localized ventilation for contamination control

  11. Radiological assessments of land disposal options: recent model developments

    International Nuclear Information System (INIS)

    Fearn, H.S.; Pinner, A.V.; Hemming, C.R.

    1984-10-01

    This report describes progress in the development of methodologies and models for assessing the radiological impact of the disposal of low and intermediate level wastes by (i) shallow land burial in simple trenches (land 1), (ii) shallow land burial in engineered facilities (land 2), and (iii) emplacement in mined repositories or existing cavities (land 3/4). In particular the report describes wasteform leaching models, for unconditioned and cemented waste, the role of engineered barriers of a shallow land burial facility in reducing the magnitude of doses arising from groundwater contact and a detailed consideration of the interactions between radioactive carbon and various media. (author)

  12. Radiological characterisation on V1 NPP technological systems and buildings - Contamination

    International Nuclear Information System (INIS)

    Hanzel, Richard; Rapant, Tibor; Svitek, Jaroslav

    2012-01-01

    Since 2001, the preparation of V1 NPP practical decommissioning has been supported and partly financed by the Bohunice International Decommissioning Support Fund, under the administration of the European bank for Reconstruction and development. AMEC Nuclear Slovakia, together with partners STM Power and EWN GmbH, performed BIDSF B.4 project - Decommissioning database development. The main purpose of the B6.4 project was to develop a comprehensive physical and radiological inventory database to support RAW management development of the decommissioning studies and decommissioning project of Bohunice V1 NPP. AMEC Nuclear Slovakia was responsible mainly for DDB design, planning documents and physical and radiological characterization including sampling and analyses of the plant controlled area. The objective of V1 NPP radiological characterization was summarisation of sampling and analyses results, description of methodology used for radiological characterization and determination of the V1 NPP radiological inventory. Results of the characterization survey included the identification and distribution of contamination in buildings, structures, and other site facilities or other impacted media. The characterization survey clearly identified those portions of the site that have been affected by site activities and are contaminated. The survey also identified the portions of the site that have not been affected by these activities and can be marked as 'not impacted'. Radiological data have been presented also on the basis of index RAI level, where 5 radiological classes have been defined. On the basis of sampling and analyses results following radiological parameters have been assigned to all impacted components and civil structures included in DDB: dose rate in contact, dose rate in distance 1 m, external surface contamination, internal surface contamination and volume/mass contamination. Each room in controlled area has been described by following radiological parameters

  13. Establishing a health outcomes and economics center in radiology: strategies and resources required

    International Nuclear Information System (INIS)

    Medina, Santiago L.; Altman, Nolan R.

    2002-01-01

    To describe the resources and strategies required to establish a health outcomes and economics center in radiology.Methods. Human and nonhuman resources required to perform sound outcomes and economics studies in radiology are reviewed.Results. Human resources needed include skilled medical and nonmedical staff. Nonhuman resources required are: (1) communication and information network; (2) education tools and training programs; (3) budgetary strategies; and (4) sources of income. Effective utilization of these resources allows the performance of robust operational and clinical research projects in decision analysis, cost-effectiveness, diagnostic performance (sensitivity, specificity, and ROC curves), and clinical analytical and experimental studies.Conclusion. As new radiologic technology and techniques are introduced in medicine, society is increasingly demanding sound clinical studies that will determine the impact of radiologic studies on patient outcome. Health-care funding is scarce, and therefore third-party payers and hospitals are demanding more efficiency and productivity from radiologic service providers. To meet these challenges, radiology departments could establish health outcomes and economics centers to study the clinical effectiveness of imaging and its impact on patient outcome. (orig.)

  14. Radiologic errors, past, present and future.

    Science.gov (United States)

    Berlin, Leonard

    2014-01-01

    During the 10-year period beginning in 1949 with publication of five articles in two radiology journals and UKs The Lancet, a California radiologist named L.H. Garland almost single-handedly shocked the entire medical and especially the radiologic community. He focused their attention on the fact now known and accepted by all, but at that time not previously recognized and acknowledged only with great reluctance, that a substantial degree of observer error was prevalent in radiologic interpretation. In the more than half-century that followed, Garland's pioneering work has been affirmed and reaffirmed by numerous researchers. Retrospective studies disclosed then and still disclose today that diagnostic errors in radiologic interpretations of plain radiographic (as well as CT, MR, ultrasound, and radionuclide) images hover in the 30% range, not too dissimilar to the error rates in clinical medicine. Seventy percent of these errors are perceptual in nature, i.e., the radiologist does not "see" the abnormality on the imaging exam, perhaps due to poor conspicuity, satisfaction of search, or simply the "inexplicable psycho-visual phenomena of human perception." The remainder are cognitive errors: the radiologist sees an abnormality but fails to render a correct diagnoses by attaching the wrong significance to what is seen, perhaps due to inadequate knowledge, or an alliterative or judgmental error. Computer-assisted detection (CAD), a technology that for the past two decades has been utilized primarily in mammographic interpretation, increases sensitivity but at the same time decreases specificity; whether it reduces errors is debatable. Efforts to reduce diagnostic radiological errors continue, but the degree to which they will be successful remains to be determined.

  15. Mobilization suited for each radiological emergency

    International Nuclear Information System (INIS)

    Chambrette, V.

    2013-01-01

    This poster presents the role played by IRSN (French Institute for Radiation protection and Nuclear Safety) in case of radiological alert. This alert can be sent by the administration, a fire brigade, a nuclear operator or a remote monitor of radioactivity. In case of an emergency situation: IRSN provides radiological intervention and assistance on the site. In case of national crisis organization, IRSN will implement the emergency technical center and will send a mobile cell to the Operational Command Station of the Prefecture concerned. In both cases IRSN will be in charge of assessing the individuals' exposure and the impact on the environment

  16. Radiological effects

    International Nuclear Information System (INIS)

    Anon.

    1978-01-01

    Environmental monitoring in the vicinity of the Calvert Cliffs Nuclear Power Plant has been shown the radiation dose to the public from plant operation to be quite small. Calculations from the reported release rates yield 0.2 mrem whole body dose and 0.6 mrem skin dose for the calendar quarter of maximum release. Radioactivity discharges to the Chesapeake Bay have resulted in detectable concentrations of /sup 110m/Ag, 58 Co, and 60 Co in sediments and shellfish. The area yielding samples with detectable concentrations of plant effluents extends for roughly six miles up and down the western shore, with maximum values found at the plant discharge area. The radiation dose to an individual eating 29 doz oysters and 15 doz crabs (5 kg of each) taken from the plant discharge area would be about 4/1000 mrem whole body dose and 0.2 mrem gastrointestinal tract dose (about 0.007% and 0.5% of the applicable guidelines, respectively.) Comparison of these power plant-induced doses with the fluctuations in natural radiation dose already experienced by the public indicates that the power plant effects are insignificant. The natural variations are tens of times greater than the maximum doses resulting from Calvert Cliffs Power Plant. Although operations to date provide an insufficient basis to predict radiological impact of the Calvert Cliffs Plant over its operational lifetime, available data indicate that the plant should continue to operate with insignificant radiological impact, well within all applicable guidelines

  17. Radiology fundamentals

    CERN Document Server

    Singh, Harjit

    2011-01-01

    ""Radiology Fundamentals"" is a concise introduction to the dynamic field of radiology for medical students, non-radiology house staff, physician assistants, nurse practitioners, radiology assistants, and other allied health professionals. The goal of the book is to provide readers with general examples and brief discussions of basic radiographic principles and to serve as a curriculum guide, supplementing a radiology education and providing a solid foundation for further learning. Introductory chapters provide readers with the fundamental scientific concepts underlying the medical use of imag

  18. Recognition difference and improvement direction of the radiological technologists and patient against medical service in department radiology - Inchon area in the object

    International Nuclear Information System (INIS)

    An, Sung Min; Kim, Sung Chul

    2006-01-01

    Satisfaction of the patient against the medical service in department of radiology and it evaluated the different recognition of radiological technologist and patient, and investigates it's improvement direction. It sent the reply the above the which is a usual result in question result of the most that, the receipt process it was complicated in the portion which is insufficient. 'The receipt process is complication', 'waiting time is long' and ' don't radiation protection for patient and guardian'. Also these a facts was recognizing patients and radiological technologist all. And the effort of the radiological technologist is necessary with the method which reduces a recognition difference. The periodical medical service satisfaction investigates and must endeavor in reform measure preparation

  19. The potential for reducing the radiological consequences of reactor decommissioning through selection of construction materials for activated components

    International Nuclear Information System (INIS)

    Woollam, P.B.

    1984-08-01

    This report considers whether it may be possible to reduce the radiological consequences of reactor decommissioning by careful attention to the specification of the elemental concentration of materials used in the reactor's construction. In particular, consideration is given to the potential for reduction of the concentration of elements known to activate to long lived daughter isotopes. Two particular areas are addressed, both applied to Sizewell 'B' PWR. The first is the choice of raw materials for the construction of the concrete bioshield to minimise future waste arisings. The second is the specification of some trace element concentrations in the steel pressure vessel and reactor internal structures to minimise personnel exposure at decommissioning time. The report presents extensive analyses of many of the candidate raw materials for Sizewell 'B' concrete, including PFA, and derives the radiological consequences for the eventual disposal of these materials to a hypothetical municipal land fill waste site. Data are also presented on the concentrations of important elements activating to gamma emitting daughters in type 304 stainless steels, leading to an assessment of likely dose equivalent rates at decommissioning time from the pressure vessel and from the internal components. (author)

  20. Poul Erik Andersen's radiological work on Osteochondrodysplasias and interventional radiology

    DEFF Research Database (Denmark)

    Andersen, Poul Erik

    2011-01-01

    Hospital. His significant experience and extensive scientific work has led to many posts in the Danish Society of Interventional Radiology, the European Society of Radiology and the Cardiovascular and Interventional Radiological Society of Europe, where he is a fellow and has passed the European Board...... of Interventional Radiology - The European qualification in Interventional Radiology....

  1. Predictions of models for environmental radiological assessment

    International Nuclear Information System (INIS)

    Peres, Sueli da Silva; Lauria, Dejanira da Costa; Mahler, Claudio Fernando

    2011-01-01

    In the field of environmental impact assessment, models are used for estimating source term, environmental dispersion and transfer of radionuclides, exposure pathway, radiation dose and the risk for human beings Although it is recognized that the specific information of local data are important to improve the quality of the dose assessment results, in fact obtaining it can be very difficult and expensive. Sources of uncertainties are numerous, among which we can cite: the subjectivity of modelers, exposure scenarios and pathways, used codes and general parameters. The various models available utilize different mathematical approaches with different complexities that can result in different predictions. Thus, for the same inputs different models can produce very different outputs. This paper presents briefly the main advances in the field of environmental radiological assessment that aim to improve the reliability of the models used in the assessment of environmental radiological impact. The intercomparison exercise of model supplied incompatible results for 137 Cs and 60 Co, enhancing the need for developing reference methodologies for environmental radiological assessment that allow to confront dose estimations in a common comparison base. The results of the intercomparison exercise are present briefly. (author)

  2. Radiological impact of natural radioactivity in Egyptian phosphate rocks, phosphogypsum and phosphate fertilizers

    International Nuclear Information System (INIS)

    El-Bahi, S.M.; Sroor, A.; Mohamed, Gehan Y.; El-Gendy, N.S.

    2017-01-01

    In this study, the activity concentrations of the natural radionuclides in phosphate rocks and its products were measured using a high- purity germanium detector (HPGe). The obtained activity results show remarkable wide variation in the radioactive contents for the different phosphate samples. The average activity concentration of "2"3"5U, "2"3"8U, "2"2"6Ra, "2"3"2Th and "4"0K was found as (45, 1031, 786, 85 and 765 Bq/kg) for phosphate rocks, (28, 1234, 457, 123 and 819 Bq/kg) for phosphate fertilizers, (47, 663, 550, 79 and 870 Bq/kg) for phosphogypsum and (25, 543, 409, 54 and 897 Bq/kg) for single super phosphate respectively. Based on the measured activities, the radiological parameters (activity concentration index, absorbed gamma dose rate in outdoor and indoor and the corresponding annual effective dose rates and total excess lifetime cancer risk) were estimated to assess the radiological hazards. The total excess lifetime cancer risk (ELCR) has been calculated and found to be high in all samples, which related to high radioactivity, representing radiological risk for the health of the population. - Highlights: • Level of radioactivity of phosphate rocks and by-products samples. • The radiological health hazard parameters. • Radiological risk to the health of the population. • The excess lifetime cancer risk factor.

  3. Evaluation of Radiological Impacts on the Operating Kartini Reactor and Natural Radioactivity of the Site Plan of Nuclear Power Plant Area

    International Nuclear Information System (INIS)

    Yazid, M; Sutresna, G; Sulistyono, A; Ngasifudin

    1996-01-01

    This radiological impacts evaluation covered of radioactivity in water, soil, grass, air samples and ambient gamma radiation that have been carried out in the Kartini reactor area and in the site plan of nuclear power plan are at Ujung Lemah Abang, Jepara, Central Java. The aim of this research was to determine that radiological impacts in the environment around the Kartini reactor compared to natural radioactivity for site plan of nuclear power plan area. The radioactivity in the water, soil and grass samples ware measured by low background beta counting system and were identified by low background gamma spectrometer. The radioactivity in the air samples was measured by beta portable counting system and the ambient gamma radiation was measured by portable high pressurized ionization chamber model RSS-112 Reuther-Stokes. The reactor data measurement was compared to the site plan of nuclear power plant area data for evaluation of radiological impacts on the operating reactor. From the evaluation and comparison can be concluded there are no indication of the radionuclide release from the reactor operation. The average radiactivity in the water, soil grass and air sample from the reactor area were between 0.17 - 0.61 Bq/1; 0,47 - 0,74 Bq/g; 4.43 - 4.60 Bq/g.ash and 49.53 - 70.90 x 10 Bq/cc. The average radioactivity of those sample from the nuclear power plant area were between 0.06-0.90 Bq/I; 0.02-0.86 Bq/g; 1.68-8.07 Bq/g.ash and 65.0-152.3 x 10 Bq/cc. The ambient gamma radiation were between 6.9-36.7 urad/h for the reactor area and 6.8-19.2 urad/h for the nuclear power plant area

  4. Guidelines on radiology standards for primary dental care

    International Nuclear Information System (INIS)

    1994-01-01

    A Joint Working Party (JWP) on patient dose reduction in diagnostic radiology was established between the Royal College of Radiologists (RCR) and the National Radiological Protection Board (NRPB) towards the end of 1988. JWP identified a large potential for patient dose reduction on a national scale, and a report of its findings was published in 1990. This guidance was only generally applicable to dental radiology and in 1992 a further joint venture between RCR and NRPB resulted in the formation of a Working Party (WP) to consider all aspects of dental radiology applicable to primary dental care. Dental radiology is one of the largest single groups of radiographic examination performed, although the effective dose per radiograph is small. This means that individual risks from dental radiology are low, but WP has identified a significant potential for reduction in the collective dose and for improvements in the diagnostic quality of radiographs. The WP recommendations cover all aspects of dental radiology: training and examination regimes for dentists and staff, patient selection and clinical justification for radiography, diagnostic interpretation, equipment and procedural aspects, and finally the question of quality assurance in dental radiology. The economic impact of the many recommendations by WP has been considered in some detail. The benefits and cost of each recommendation either have been assigned a monetary value or have been assessed more qualitatively. The conclusion is that there is a strong economic justification for implementation of the full package of recommendations. (Author)

  5. Protection of staff in interventional radiology

    International Nuclear Information System (INIS)

    Melkamu, M. A.

    2013-04-01

    This project focuses on the interventional radiology. The main objective of this project work was to provide a guidance and advice for occupational exposure and hospital management to optimize radiation protection safety and endorse safety culture. It provides practical information on how to minimize occupational exposure in interventional radiology. In the literature review all considerable parameters to reduce dose to the occupationally exposed are well discussed. These parameters include dose limit, risk estimation, use of dosimeter, personal dose record keeping, analysis of surveillance of occupational dose, investigation levels, and proper use of radiation protection tools and finally about scatter radiation dose rate. In addition the project discusses the ways to reduce occupational exposure in interventional radiology. The methods for dose reduction are minimizing fluoroscopic time, minimizing the number of fluoroscopic image, use of patient dose reduction technologies, use of collimation, planning interventional procedures, positioning in low scattered areas, use of protective shielding, use of appropriate fluoroscopic imaging equipment, giving training for the staff, wearing the dosimeters and know their own dose regularly, and management commitment to quality assurance and quality control system and optimization of radiation protection of safety. (author)

  6. Radiological impact assessment for a severe accident scenario for a CANDU 6 type NPP

    International Nuclear Information System (INIS)

    Penescu, Maria; Mehedinteanu, Stefan; Cruceanu, Amalia; Ispas, Georgeta

    2004-01-01

    There are two main categories of consequences of accidental activity releases, which involve radiological considerations. First, there is the health detriment in the exposed population and its descendants; secondly, there is the economic and social impact from the restrictions generated by the control of that population exposure. A variety of health effects may be predicted to occur in an exposed population, depending on the magnitude and distribution of the exposure. Early effects include both death and varying degrees of health impairment, but these are likely to occur only following extremely large activity releases. The major late effects are cancer, both fatal and nonfatal, in the exposed population and heredity effects in their descendants. A variety of radiological endpoints can be calculated to provide a measure of the overall impact. Those, which are considered to be most useful in context of, risk analysis and in the analyses of siting, emergency planning and design criteria can be summarized as: - the incidence of particular health effects in the exposed population and its descendants; - the number of people who may be affected by the application of the countermeasures; - the areas of land beyond particular levels, especially those in which restrictions may be needed with respect of their use or on foodstuffs derived from them; - the economic cost of introducing countermeasures, particularly restrictions on the use of contaminated land and property. A number of countermeasures could be introduced to reduce doses following an accidental release. Such measures are the evacuation and relocation of population and the banning of contaminated food consumption. Sheltering before evacuation is also considered. The criteria for taking the decision to evacuate are based on the total dose and dose for each organ resulted from the exposure to the plume and inhalation, while the criterion for relocation is based simply on the external dose from deposited activity

  7. Chronicle of pediatric radiology

    International Nuclear Information System (INIS)

    Benz-Bohm, Gabriele; Richter, Ernst

    2012-01-01

    The chronicle of pediatric radiology covers the following issues: Development of pediatric radiology in Germany (BRD, DDR, pediatric radiological accommodations); development of pediatric radiology in the Netherlands (chronology and pediatric radiological accommodations); development of pediatric radiology in Austria (chronology and pediatric radiological accommodations); development of pediatric radiology in Switzerland (chronology and pediatric radiological accommodations).

  8. Preventing radiological terrorism - opportunities and challenges

    International Nuclear Information System (INIS)

    Barlow, Maegon E.

    2016-01-01

    The Office of Radiological Security (ORS), within the U.S. Department of Energy's National Nuclear Security Administration, enhances global security by preventing high activity radioactive materials from use in acts of terrorism. This is a challenging task considering that high activity radiological materials are ubiquitous, constantly moving and mostly found in operational civil facilities. The implementation of the ORS mission is based on a three pillar strategy - protect, remove and reduce. ORS works both domestically and internationally with government authorities, law enforcement, and businesses to protect radioactive sources used for vital medical, research, and commercial purposes, remove and dispose of disused radioactive sources, and reduce the global reliance on radioactive sources through the promotion of viable non-isotopic alternative technologies. ORS has active engagement in all 50 States and in over 80 countries. This presentation will provide an overview of ORS protect, remove, and reduce strategy, as well as security challenges and opportunities

  9. Radiological conditions and experiences in the TMI-2 Auxiliary Building

    International Nuclear Information System (INIS)

    Ruhter, P.E.; Zurliene, W.G.

    1988-01-01

    Although the radiological conditions following the TMI-2 accident were extraordinary, those that had a potential impact on personnel were largely confined to the Auxiliary and Fuel Handling Building. The most significant pathway was the Letdown and Make-Up and Purification System. Dose rates in some locations in the Aux/Fuel Handling Buildings were in excess of 3 mSv/s (1000 R/h) during the first few days following the accident. They decreased after three to four days and stabilized after about one week. Airborne radioactivity levels were initially due to the release of noble gases, and subsequently due to resuspension of surface contamination. During the first month, the mixture of fission products in the reactor coolant change from one of largely cesium to where the strontium and cesium were about equal in radiological importance. This created some very high beta radiation levels. The significant strontium levels caused the contamination control limit to be reduced to one-half of the pre-accident limit. 5 refs., 6 figs

  10. Entrepreneurial Women in Radiology: Role Models of Success.

    Science.gov (United States)

    Anzai, Yoshimi; Meltzer, Carolyn C; DeStigter, Kristen K; Destounis, Stamatia; Pawley, Barbara K; Oates, M Elizabeth

    2016-11-01

    Radiology is undeniably male dominated. Alongside surgery and orthopedic surgery, academic radiology ranks near the bottom in having the lowest proportion of full-time female faculty members. Despite many efforts to recruit talented women, the pipeline entering the radiologic disciplines continues to flow at a trickle. One factor is the relative lack of role models for female medical students. Entrepreneurial women in radiology can lead the field with their innovation and creativity, courage, and commitment. In this article, the authors highlight two entrepreneurial female radiologists who shared their success stories at the American Association for Women Radiologists' session at the 2015 ACR annual meeting. Their successes underscore the potential for such women to serve as role models to female medical students and even college undergraduates. Despite the gender gap in radiology, the field has yielded some exceptional women who can take on challenges, overcome barriers and assume risks, create strategies and processes to operationalize their visions, secure funding, and expand their enterprises to make sustainable impacts both at home and abroad. As we move toward more patient- and family-centered care models and become increasingly visible to diverse populations, there is no better time for female leaders in radiology to inspire the next generation to join our essential and rewarding specialty. Copyright © 2016 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  11. Bibliometric Analysis of Manuscript Characteristics That Influence Citations: A Comparison of Six Major Radiology Journals.

    Science.gov (United States)

    Shekhani, Haris Naseem; Shariff, Shoaib; Bhulani, Nizar; Khosa, Faisal; Hanna, Tarek Noel

    2017-12-01

    The objective of our study was to investigate radiology manuscript characteristics that influence citation rate, capturing features of manuscript construction that are discrete from study design. Consecutive articles published from January 2004 to June 2004 were collected from the six major radiology journals with the highest impact factors: Radiology (impact factor, 5.076), Investigative Radiology (2.320), American Journal of Neuroradiology (AJNR) (2.384), RadioGraphics (2.494), European Radiology (2.364), and American Journal of Roentgenology (2.406). The citation count for these articles was retrieved from the Web of Science, and 29 article characteristics were tabulated manually. A point-biserial correlation, Spearman rank-order correlation, and multiple regression model were performed to predict citation number from the collected variables. A total of 703 articles-211 published in Radiology, 48 in Investigative Radiology, 106 in AJNR, 52 in RadioGraphics, 129 in European Radiology, and 157 in AJR-were evaluated. Punctuation was included in the title in 55% of the articles and had the highest statistically significant positive correlation to citation rate (point-biserial correlation coefficient [r pb ] = 0.85, p radiology. Using bibliometric knowledge, authors can craft a title, abstract, and text that may enhance visibility and citation count over what they would otherwise experience.

  12. Progress in reducing the environmental impacts of offshore drilling wastes

    International Nuclear Information System (INIS)

    Flemming, D; Candler, J.E.

    2002-01-01

    Full text:Over the past several years, great progress has been made in understanding and reducing the environmental impacts of offshore drilling wastes. Our understanding of sea floor impacts has been helped along by new environmental assessment tools such us computer modeling of sea floor deposition of drilling discharges, sediment profile imaging, and in situ sediment toxicity bioassays. To further reduce environmental impacts, new pollution prevention technologies have been developed that can shrink the environmental footprint of offshore drilling. These technologies reduce the total amount of drilling wastes discharged and include cuttings dryers and centrifuges that can reduce the drilling fluid content of drill cuttings to below 10 percent. In conclusion, the oil and gas industry is adopting more environmentally compatible drilling fluids, new environmental assessment tools and pollution prevention technologies that dramatically reduce the amount of drilling wastes discharged. Together, all of these elements have the potential to reduce environmental impacts of offshore drilling

  13. Imaging and radiology

    Science.gov (United States)

    Interventional radiology; Diagnostic radiology; X-ray imaging ... DIAGNOSTIC RADIOLOGY Diagnostic radiology helps health care professionals see structures inside your body. Doctors that specialize in the interpretation ...

  14. A common approach for radiological protection of humans and the environment

    International Nuclear Information System (INIS)

    Holm, L.-E.

    2004-01-01

    Protection of the environment is developing rapidly at the national and international level, but there are still no internationally agreed recommendations as to how radiological protection of the environment should be carried out. The International Commission on Radiological Protection (ICRP) is currently reviewing its existing recommendations for human protection. It has set up a task group with the aim of developing a protection policy for, and suggesting a framework of, the protection of the environment that could feed into its recommendations at the start of the 21st century. The task group will propose a framework for the protection of the environment from harmful effects of radiation, harmonising with the principles for the protection of humans. Although the task group has not yet finalised on the objectives for the environment, these might be to safeguard the environment by preventing or reducing the frequency of effects likely to cause early mortality, reduced reproductive success, or the occurrence of scorable DNA damage in individual fauna and flora to a level where they would have a negligible impact on conservation of species, maintenance of biodiversity, or the health and status of natural habitats or communities. To achieve these objectives, a set of reference dose models, reference dose per unit intake and reference organisms will be required

  15. Radiological impact of diagnostic nuclear medicine technology on the Quebec population (patients and workers) in 1989

    International Nuclear Information System (INIS)

    Renaud, L.; Blanchette, J.

    1992-01-01

    Using the results of a six month survey on the doses received by non-monitored hospital workers from diagnostic nuclear medicine patients (DNMP) in three hospitals and published statistics on Quebec's workers and hospitals, an evaluation of the radiological impact of DNMP has been calculated on the Quebec's population. In 1989, diagnostic nuclear medicine gave an average of 6.4 mSv/act or a total of 2,800 sv-man. The diagnostic nuclear medicine technologists' community received 0.4 Sv-man and the non-monitored hospital workers 1.7 Sv-man from the DNMP in the same year. (author)

  16. Radiological Control Manual

    Energy Technology Data Exchange (ETDEWEB)

    1993-04-01

    This manual has been prepared by Lawrence Berkeley Laboratory to provide guidance for site-specific additions, supplements, and clarifications to the DOE Radiological Control Manual. The guidance provided in this manual is based on the requirements given in Title 10 Code of Federal Regulations Part 835, Radiation Protection for Occupational Workers, DOE Order 5480.11, Radiation Protection for Occupational Workers, and the DOE Radiological Control Manual. The topics covered are (1) excellence in radiological control, (2) radiological standards, (3) conduct of radiological work, (4) radioactive materials, (5) radiological health support operations, (6) training and qualification, and (7) radiological records.

  17. Radiological Control Manual

    International Nuclear Information System (INIS)

    1993-04-01

    This manual has been prepared by Lawrence Berkeley Laboratory to provide guidance for site-specific additions, supplements, and clarifications to the DOE Radiological Control Manual. The guidance provided in this manual is based on the requirements given in Title 10 Code of Federal Regulations Part 835, Radiation Protection for Occupational Workers, DOE Order 5480.11, Radiation Protection for Occupational Workers, and the DOE Radiological Control Manual. The topics covered are (1) excellence in radiological control, (2) radiological standards, (3) conduct of radiological work, (4) radioactive materials, (5) radiological health support operations, (6) training and qualification, and (7) radiological records

  18. Radiological English

    Energy Technology Data Exchange (ETDEWEB)

    Ribes, R. [Hospital Reina Sofia, Cordoba (Spain). Servicio de Radiologia; Ros, P.R. [Harvard Medical School, Boston, MA (United States). Div. of Radiology

    2007-07-01

    The book is an introductory book to radiological English on the basis that there are a lot of radiologists, radiology residents, radiology nurses, radiology students, and radiographers worldwide whose English level is indeterminate because their reading skills are much higher than their fluency. It is intended to help those health care professionals who need English for their work but do not speak English on a day-to-day basis. (orig.)

  19. Radiological English

    International Nuclear Information System (INIS)

    Ribes, R.; Ros, P.R.

    2007-01-01

    The book is an introductory book to radiological English on the basis that there are a lot of radiologists, radiology residents, radiology nurses, radiology students, and radiographers worldwide whose English level is indeterminate because their reading skills are much higher than their fluency. It is intended to help those health care professionals who need English for their work but do not speak English on a day-to-day basis. (orig.)

  20. Diagnostic radiology on multiple injured patients: interdisciplinary management

    International Nuclear Information System (INIS)

    Linsenmaier, U.; Pfeifer, K.J.; Kanz, K.G.; Mutschler, W.

    2001-01-01

    The presence of a radiologist within the admitting area of an emergency department and his capability as a member of the trauma team have a major impact on the role of diagnostic radiology in trauma care. The knowledge of clinical decision criteria, algorithms, and standards of patient care are essential for the acceptance within a trauma team. We present an interdisciplinary management concept of diagnostic radiology for trauma patients, which comprises basic diagnosis, organ diagnosis, radiological ABC, and algorithms of early clinical care. It is the result of a prospective study comprising over 2000 documented multiple injured patients. The radiologist on a trauma team should support trauma surgery and anesthesia in diagnostic and clinical work-up. The radiological ABC provides a structured approach for diagnostic imaging in all steps of the early clinical care of the multiple injured patient. Radiological ABC requires a reevaluation in cases of equivocal findings or difficulties in the clinical course. Direct communication of radiological findings with the trauma team enables quick clinical decisions. In addition, the radiologist can priority-oriented influence the therapy by using interventional procedures. The clinical radiologist is an active member of the interdisciplinary trauma team, not only providing diagnostic imaging but also participating in clinical decisions. (orig.) [de

  1. Handbook of radiologic procedures

    International Nuclear Information System (INIS)

    Hedgcock, M.

    1986-01-01

    This book is organized around radiologic procedures with each discussed from the points of view of: indications, contraindications, materials, method of procedures and complications. Covered in this book are: emergency radiology chest radiology, bone radiology, gastrointestinal radiology, GU radiology, pediatric radiology, computerized tomography, neuroradiology, visceral and peripheral angiography, cardiovascular radiology, nuclear medicine, lymphangiography, and mammography

  2. The Role of Artificial Intelligence in Diagnostic Radiology: A Survey at a Single Radiology Residency Training Program.

    Science.gov (United States)

    Collado-Mesa, Fernando; Alvarez, Edilberto; Arheart, Kris

    2018-02-21

    Advances in artificial intelligence applied to diagnostic radiology are predicted to have a major impact on this medical specialty. With the goal of establishing a baseline upon which to build educational activities on this topic, a survey was conducted among trainees and attending radiologists at a single residency program. An anonymous questionnaire was distributed. Comparisons of categorical data between groups (trainees and attending radiologists) were made using Pearson χ 2 analysis or an exact analysis when required. Comparisons were made using the Wilcoxon rank sum test when the data were not normally distributed. An α level of 0.05 was used. The overall response rate was 66% (69 of 104). Thirty-six percent of participants (n = 25) reported not having read a scientific medical article on the topic of artificial intelligence during the past 12 months. Twenty-nine percent of respondents (n = 12) reported using artificial intelligence tools during their daily work. Trainees were more likely to express doubts on whether they would have pursued diagnostic radiology as a career had they known of the potential impact artificial intelligence is predicted to have on the specialty (P = .0254) and were also more likely to plan to learn about the topic (P = .0401). Radiologists lack exposure to current scientific medical articles on artificial intelligence. Trainees are concerned by the implications artificial intelligence may have on their jobs and desire to learn about the topic. There is a need to develop educational resources to help radiologists assume an active role in guiding and facilitating the development and implementation of artificial intelligence tools in diagnostic radiology. Copyright © 2017 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  3. Generic performance assessment for a deep repository for low and intermediate level waste in the UK - a case study in assessing radiological impacts on the natural environment

    International Nuclear Information System (INIS)

    Jones, S.R.; Patton, D.; Copplestone D.; Norris, S.; O'Sullivan, P.

    2003-01-01

    Concentrations of radionuclides in soil and surface water, taken from a generic performance assessment of a repository for low and intermediate level radioactive waste, assumed to be located in the UK, have been used as the basis for a case study in assessing radiological impacts on the natural environment. Simplified descriptions of the terrestrial and aquatic ecosystem types likely to be impacted have been developed. A scoping assessment has identified 226 Ra, 210 Po, 234 U, 230 Th and 238 U as having the highest potential for impact, with doses from internally incorporated alpha emitters as being potentially of particular importance. These nuclides, together with 36 Cl and 129 I (which have proved to be of importance in radiological risk assessments for humans) were included in a more detailed dose assessment. A basic methodology for dose assessment of ecosystems is described, and has been applied for the defined impacted ecosystems. Paucity of published data on concentration factors prevented a more detailed assessment for terrestrial ecosystems. For the aquatic ecosystem, a more detailed assessment was possible and highest calculated absorbed dose rates (weighted for the likely higher biological effectiveness of alpha radiation were about 6.5 μGy h -1 . We conclude that harm to the impacted ecosystems is unlikely and make the observation that the lack of concentration factor or transfer factor data for a sufficiently wide range of species, ecosystems and nuclides appears to be the principal obstacle to establishing a comprehensive framework for the application of radiological protection to ecosystems

  4. Workplace Bullying in Radiology and Radiation Oncology.

    Science.gov (United States)

    Parikh, Jay R; Harolds, Jay A; Bluth, Edward I

    2017-08-01

    Workplace bullying is common in health care and has recently been reported in both radiology and radiation oncology. The purpose of this article is to increase awareness of bullying and its potential consequences in radiology and radiation oncology. Bullying behavior may involve abuse, humiliation, intimidation, or insults; is usually repetitive; and causes distress in victims. Workplace bullying is more common in health care than in other industries. Surveys of radiation therapists in the United States, student radiographers in England, and physicians-in-training showed that substantial proportions of respondents had been subjected to workplace bullying. No studies were found that addressed workplace bullying specifically in diagnostic radiology or radiation oncology residents. Potential consequences of workplace bullying in health care include anxiety, depression, and health problems in victims; harm to patients as a result of victims' reduced ability to concentrate; and reduced morale and high turnover in the workplace. The Joint Commission has established leadership standards addressing inappropriate behavior, including bullying, in the workplace. The ACR Commission on Human Resources recommends that organizations take steps to prevent bullying. Those steps include education, including education to ensure that the line between the Socratic method and bullying is not crossed, and the establishment of policies to facilitate reporting of bullying and support victims of bullying. Copyright © 2016 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  5. RSVP radiology

    International Nuclear Information System (INIS)

    Kirks, D.R.; Chaffee, D.J.

    1990-01-01

    This paper develops a relative scale of value for pediatric radiology (RSVPR). Neither the HCFA/ACA Relative Value Scale nor the Workload Measurement System developed by Health and Welfare Canada specifically addressed pediatric radiologic examinations. Technical and professional charges for examinations at Children's Hospital Medical Center were reviewed and compared with time and cost analysis. A scale was developed with chest radiography (PA and lateral views) assigned a value of 1. After review by pediatric radiologic technologists, radiologic administrators, pediatric radiologists, and chairs of departments of children's hospitals, this proposed scale was modified to reflect more accurately relative value components of pediatric radiologic and imaging examinations

  6. A method to reduce patient's eye lens dose in neuro-interventional radiology procedures

    International Nuclear Information System (INIS)

    Safari, M.J.; Wong, J.H.D.; Kadir, K.A.A.; Sani, F.M.; Ng, K.H.

    2016-01-01

    Complex and prolonged neuro-interventional radiology procedures using the biplane angiography system increase the patient's risk of radiation-induced cataract. Physical collimation is the most effective way of reducing the radiation dose to the patient's eye lens, but in instances where collimation is not possible, an attenuator may be useful in protecting the eyes. In this study, an eye lens protector was designed and fabricated to reduce the radiation dose to the patients’ eye lens during neuro-interventional procedures. The eye protector was characterised before being tested on its effectiveness in a simulated aneurysm procedure on an anthropomorphic phantom. Effects on the automatic dose rate control (ADRC) and image quality are also evaluated. The eye protector reduced the radiation dose by up to 62.1% at the eye lens. The eye protector is faintly visible in the fluoroscopy images and increased the tube current by a maximum of 3.7%. It is completely invisible in the acquisition mode and does not interfere with the clinical procedure. The eye protector placed within the radiation field of view was able to reduce the radiation dose to the eye lens by direct radiation beam of the lateral x-ray tube with minimal effect on the ADRC system. - Highlights: • The eye protector can considerably reduce the patient's eye lens dose during neuro-interventional procedures. • This protector does not significantly perturb the fluoroscopy image and was completely invisible on the acquisition image due to image subtraction. • The eye protector does not significantly change the exposure parameters (kV and mAs).

  7. Gonad shielding in diagnostic radiology

    International Nuclear Information System (INIS)

    1975-06-01

    The use of gonad shielding is an important radiation protection technique, intended to reduce unnecessary x-ray exposure of the gonads of patients from diagnostic x-ray procedures. This pamphlet will provide physicians and radiologic technologists with information which will aid their appropriate use of gonad shielding

  8. Radiological anatomy - evaluation of integrative education in radiology.

    Science.gov (United States)

    Dettmer, S; Schmiedl, A; Meyer, S; Giesemann, A; Pabst, R; Weidemann, J; Wacker, F K; Kirchhoff, T

    2013-09-01

    Evaluation and analysis of the integrative course "Radiological Anatomy" established since 2007 at the Medical School Hannover (MHH) in comparison with conventional education. Anatomy and radiology are usually taught separately with a considerable time lag. Interdisciplinary teaching of these associated subjects seems logical for several reasons. Therefore, the integrative course "Radiological Anatomy" was established in the second year of medical education, combining these two closely related subjects. This interdisciplinary course was retrospectively evaluated by consideration of a student questionnaire and staff observations. The advantages and disadvantages of integrative teaching in medical education are discussed. The course ratings were excellent (median 1; mean 1.3 on a scale of 1 to 6). This is significantly (p radiology increased during the course (88 %). According to the students' suggestions the course was enhanced by a visitation in the Department of Radiology and the additional topic central nervous system. Integrative teaching of anatomy and radiology was well received by the students. Both, anatomical and radiological comprehension and the motivation to learn were improved. However, it should be considered, that the amount of work and time required by the teaching staff is considerably increased compared to traditional teaching. © Georg Thieme Verlag KG Stuttgart · New York.

  9. Analysis of the Radiology Reports from Radiology Clinics

    International Nuclear Information System (INIS)

    Kim, Eun Jin; Kwack, Kyu Sung; Cho, Jae Hyun; Jang, Eun Ho

    2009-01-01

    The purpose of this study was to investigate the form and content of the radiology reports from radiology clinics in Korea. One hundred and sixty six radiology reports from 49 radiology clinics were collected, and these reports were referred to the academic tertiary medical center from March 2008 to February 2009. These included reports for CT (n = 18), MRI (n = 146) and examinations not specified (n = 2). Each report was evaluated for the presence of required contents (demographics, technical information, findings, conclusion, the name, license number and signature of the radiologist and the referring facility). These requirements were based on the guideline of the American College of Radiology and the previous research. The name of the patient, the gender, the body part, the type of examination, the time of examination and the conclusion, the name of the radiologist and the name of facility were well recorded in over 90% of the radiology reports. However, the identification number of the patient, the referring facility, the referring physician, the use of contrast material, the clinical information, the time of dictation, the signature of the radiologist and the license number of the radiologist were poorly recorded (less than 50%). The optimal format of a radiology report should be established for reliable and valid communication with clinicians

  10. Soils radiological characterization under a nuclear facility - 59046

    International Nuclear Information System (INIS)

    Aubonnet, Emilie; Dubot, Didier

    2012-01-01

    Nowadays, nuclear industry is facing a crucial need in establishing radiological characterization for the appraisal and the monitoring of any remediation work. Regarding its experience in this domain, the French Alternative Energies and Atomic Energy Commission (CEA) of Fontenay-aux- Roses, established an important feedback and developed over the last 10 years a sound methodology for radiological characterization. This approach is based on several steps: - historical investigations; - assumption and confirmation of the contamination; - surface characterization; - in-depth characterization; - rehabilitation objectives; - remediation process. The amount of measures, samples and analysis is optimized for data processing using geo-statistics. This approach is now used to characterize soils under facilities. The paper presents the radiological characterization of soils under a facility basement. This facility has been built after the first generation of nuclear facilities, replacing a plutonium facility which has been dismantled in 1960. The presentation details the different steps of radiological characterization from historical investigations to optimization of excavation depths, impact studies and contaminated volumes. (authors)

  11. Assessment of the radiological control at the IPEN radioisotope production facility

    International Nuclear Information System (INIS)

    Carneiro, Janete C.G.G.; Sanches, Matias P.; Rodrigues, Demerval L.; Campos, Daniela; Nogueira, Paulo R.; Damato, Sandra R.; Pecequilo, Brigitte R.

    2014-01-01

    The main objective of this work is to evaluate the 2013 annual radiological control results in the radiopharmaceuticals areas of the Instituto de Pesquisas Energeticas e Nucleares, IPEN/SP, and the environmental radiological impact, resulting from the practices there performed. The current evaluation was performed through the analysis of the results obtained from occupational and environmental monitoring with air samplers and TL dosimeters. All monitoring results were compared with the limits established by national standards. The radionuclides detected by air sampling (in charcoal and paper filters) at the workplace during radioisotope production were 131 I, 99m Tc and 99 Mo, with activities concentrations values below the annual limits values. For the radioactive gaseous releases (Bq/m 3 ), the activities concentrations also remained below the maximum permissible values, excepting to 125 I release due to an unusual event occurred in a researcher laboratory, but the radiological impact to environmental was no significant. The occupational monitoring assessment was confirmed by the Environmental Radiological Monitoring Program results with air samplers and TL dosimeters. The mean annual background radiation at IPEN in 2013, according to the Environmental Radiological Monitoring Program results was 1.06 mSv. y -1 , below the ICRP 103 recommended limit of 20 mSv.y -1 for workers. (author)

  12. Time Is Not on Our Side: How Radiology Practices Should Manage Customer Queues.

    Science.gov (United States)

    Loving, Vilert A; Ellis, Richard L; Rippee, Robert; Steele, Joseph R; Schomer, Donald F; Shoemaker, Stowe

    2017-11-01

    As health care shifts toward patient-centered care, wait times have received increasing scrutiny as an important metric for patient satisfaction. Long queues form when radiology practices inefficiently service their customers, leading to customer dissatisfaction and a lower perception of value. This article describes a four-step framework for radiology practices to resolve problematic queues: (1) analyze factors contributing to queue formation; (2) improve processes to reduce service times; (3) reduce variability; (4) address the psychology of queues. Copyright © 2017 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  13. Routine Radiological Environmental Monitoring Plan. Volume 1

    Energy Technology Data Exchange (ETDEWEB)

    Bechtel Nevada

    1999-12-31

    The U.S. Department of Energy manages the Nevada Test Site in a manner that meets evolving DOE Missions and responds to the concerns of affected and interested individuals and agencies. This Routine Radiological Monitoring Plan addressess complicance with DOE Orders 5400.1 and 5400.5 and other drivers requiring routine effluent monitoring and environmental surveillance on the Nevada Test Site. This monitoring plan, prepared in 1998, addresses the activities conducted onsite NTS under the Final Environmental Impact Statement and Record of Decision. This radiological monitoring plan, prepared on behalf of the Nevada Test Site Landlord, brings together sitewide environmental surveillance; site-specific effluent monitoring; and operational monitoring conducted by various missions, programs, and projects on the NTS. The plan provides an approach to identifying and conducting routine radiological monitoring at the NTS, based on integrated technical, scientific, and regulatory complicance data needs.

  14. Scientific issues and emerging challenges for radiological protection

    International Nuclear Information System (INIS)

    2007-01-01

    Scientific knowledge is constantly evolving as more advanced technologies become available and more in-depth research is carried out. Given the potential implications that new findings could have on policy decisions, in 1998 the NEA Committee on Radiation Protection and Public Health (CRPPH) performed a survey of state-of-the-art research in radiological protection science. This study suggested that, while the current system of radiological protection was well under-pinned by scientific understanding, growing knowledge in several areas could seriously impact policy and regulation. Ten years later, the CRPPH has again performed a survey of state-of-the-art research which reiterates and clarifies its earlier conclusions. This report summarises the results of this latest CRPPH assessment of radiological protection science. Specifically, it explains that knowledge of non-targeted and delayed effects, as well as of individual sensitivity, have been significantly refined over the past ten years. Although at this point there is still no scientific certainty in these areas, based on the most recent studies and results, the report strongly suggests that policy makers and regulatory authorities should consider possible impacts that could arise from research in the next few years. Further, the report identifies research areas that should be supported to more definitively answer scientific questions having the most direct impacts on policy choices. (author)

  15. Impact Delivery of Reduced Greenhouse Gases on Early Mars

    Science.gov (United States)

    Haberle, R. M.; Zahnle, K. J.; Barlow, N. G.

    2017-12-01

    Reducing greenhouse gases are the latest trend in finding solutions to the early Mars climate dilemma. In thick CO2 atmospheres with modest concentrations of H2 and/or CH4, collision induced absorptions can reduce the outgoing long wave radiation enough to provide a significant greenhouse effect. To raise surface temperatures significantly by this process, surface pressures must be at least 500 mb and H2 and/or CH4 concentrations must be at or above the several percent level. Volcanism, serpentinization, and impacts are possible sources for reduced gases. Here we investigate the delivery of such gases by impact degassing from comets and asteroids. We use a time-marching stochastic impactor model that reproduces the observed crater size frequency distribution of Noachian surfaces. Following each impact, reduced gases are added to the atmosphere from a production function based on gas equilibrium calculations for several classes of meteorites and comets at typical post-impact temperatures. Escape and photochemistry then remove the reduced greenhouse gases continuously in time throughout each simulation. We then conduct an ensemble of simulations with this simple model varying the surface pressure, impact history, reduced gas production and escape functions, and mix of impactor types, to determine if this could be a potentially important part of the early Mars story. Our goal is to determine the duration of impact events that elevate reduced gas concentrations to significant levels and the total time of such events throughout the Noachian. Our initial simulations indicate that large impactors can raise H2 concentrations above the 10% level - a level high enough for a very strong greenhouse effect in a 1 bar CO2 atmosphere - for millions of years, and that the total time spent at or above that level can be in the 10's of millions of years range. These are interesting results that we plan to explore more thoroughly for the meeting.

  16. Radiology research in mainland China in the past 10 years: a survey of original articles published in Radiology and European Radiology.

    Science.gov (United States)

    Zhang, Long Jiang; Wang, Yun Fei; Yang, Zhen Lu; Schoepf, U Joseph; Xu, Jiaqian; Lu, Guang Ming; Li, Enzhong

    2017-10-01

    To evaluate the features and trends of Radiology research in Mainland China through bibliometric analysis of the original articles published in Radiology and European Radiology (ER) between 2006 and 2015. We reviewed the original articles published in Radiology and ER between 2006 and 2015. The following information was abstracted: imaging subspecialty, imaging technique(s) used, research type, sample size, study design, statistical analysis, study results, funding declarations, international collaborations, number of authors, department and province of the first author. All variables were examined longitudinally over time. Radiology research in Mainland China saw a substantial increase in original research articles published, especially in the last 5 years (P Radiology research, neuroradiology, vascular/interventional Radiology, and abdominal Radiology were the most productive fields; MR imaging was the most used modality, and a distinct geographic provenience was observed for articles published in Radiology and ER. Radiology research in Mainland China has seen substantial growth in the past 5 years with neuroradiology, vascular/interventional Radiology, and abdominal Radiology as the most productive fields. MR imaging is the most used modality. Article provenience shows a distinct geographical pattern. • Radiology research in Mainland China saw a substantial increase. • Neuroradiology, vascular/interventional Radiology, and abdominal Radiology are the most productive fields. • MRI is the most used modality in Mainland China's Radiology research. • Guangdong, Shanghai, and Beijing are the most productive provinces.

  17. Comparison of the waste management aspects of spent fuel disposal and reprocessing: post-disposal radiological impact

    International Nuclear Information System (INIS)

    Mobbs, S.F.; Harvey, M.P.; Martin, J.S.; Mayall, A.; Jones, M.E.

    1991-01-01

    A joint project involving contractors from France, Germany and the UK was set up by the Commission of the European Communities to assess the implications of two waste management options: the direct disposal of spent fuel and reprocessing of that fuel. This report describes the calculation of the radiological impact on the public of the management and disposal of the wastes associated with these two options. Six waste streams were considered: discharge of liquid reprocessing effluents, discharge of gaseous reprocessing effluents, disposal of low-level solid wastes arising from reprocessing, disposal of intermediate-level solid wastes arising from reprocessing, disposal of vitrified high-level reprocessing wastes, and direct disposal of spent fuel. The results of the calculations are in the form of maximum annual doses and risks to individual members of the public, and collective doses to four population groups, integrated over six time periods. These results were designed for input into a computer model developed by another contractor, Yard Ltd, which combines costs and impacts in a multi-attribute hierarchy to give an overall measure of the impact of a given option

  18. Introduction of radiological protection; Pengenalan kepada perlindungan radiologi

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1988-12-31

    The chapter briefly discussed the following subjects: basic principles of radiological protection , dose limit which was suggested, stochastic and nonstochastic effects, equivalent dose and alternative of it`s calculation, limit for the publics, ICRP (International Commission for Radiological Protection) recommendations, and the principles of radiological protection. Dangerous radiation sources also briefly summarized i.e. x-ray generators, reactor nucleus.

  19. Development and application of portable mobile gamma spectrometry system (PMGSS) for realtime online radiological assessment

    International Nuclear Information System (INIS)

    Patil, S.S.; Padmanabhan, N.; Sharma, R.; Singh, R.; Pradeepkumar, K.S.

    2008-01-01

    A state of art mobile monitoring system is a prime requirement to combat the challenging radiological situations. In the event of any radiological/nuclear Emergencies an effective, realistic methodology of radiological measurements is an asset. In this context, a highly sensitive real-time online mobile monitoring system having features and provision to display the important parameters will be an essential tool in the course of radiological impact assessment. This paper, describes the efforts that has been made towards providing a useful Portable Mobile Gamma Spectrometry System (PMGSS) and developing applications so as to enhance its usefulness in quick radiological impact assessment and to initiate the proper countermeasures during any Nuclear/Radiological emergency situation in public domain. The system uses a NaI(Tl) detector, a global positioning system (GPS) and a laptop PC for storage, analysis and graphical representation of the acquired data. PMGSS is a highly sensitive, portable and reliable radiation monitoring equipment with capability of qualitative and quick estimation of the radioisotopes. The system was used for the mobile radiological mapping of Bangalore and Mumbai city and demonstrated its capability for use in environmental radiation monitoring during any radiological emergency requirement the results of which are presented here. (abstract)

  20. Assessment of radiological impact in mineral industrial plants caused by deposition of wastes with U{sup 238} and/or Th{sup 232} associated

    Energy Technology Data Exchange (ETDEWEB)

    Ladeira, Paula C.; Alves, Rex Nazare, E-mail: rexnazare@ime.eb.b [Instituto Militar de Engenharia (IME), Rio de Janeiro, RJ (Brazil); Ruperti Junior, Nerbe J., E-mail: nruperti@cnen.gov.b [Comissao Nacional de Energia Nuclear (DIREJ/CNEN-RJ), Rio de Janeiro, RJ (Brazil). Div. de Rejeitos Radioativos

    2011-07-01

    The industrial-mining facilities constantly produce, in Brazil and in abroad, wastes from its production, many times containing uranium and/or thorium associated. Due to the large quantities generated, these wastes are usually deposited at the site of the facility, close to the place where they were produced. Since the chains of radioactive U{sup 238} and Th{sup 232} with alpha-emitting radionuclides have long half-life, waste deposits associated with these elements may cause radiological impact on the man and on the environment, even in the long term. Mathematical models are often used to represent the biosphere and the transport of radionuclides near to the surface. Thus, it was decided, through the software {sup M}athematica{sup ,} to present a methodology based on the solution of Bateman equations for the calculation of radiological impact on individuals from the public exposed to contamination. The radiological impact appraisal was carried out considering a scenario of intrusion into landfills containing U{sup 238} and / or Th{sup 232} in post-operational phase of an industrial-mining installation. The critical group examined was represented by farmers who used water from an artesian well for daily consumption and which feed themselves on vegetables locally grown in clay soil. As a result, there was the exposure in pathways evaluated, a minor contribution of dose for ingestion of contaminated water. The conclusion of this work, show us that calculated doses were within the accepted international limits for the intrusion scenario. Parameters associated with mathematical models defining the choice of project to build a landfill for the purpose of deposition, whereas rates of doses can be estimated in each of the scenarios proposed. (author)

  1. Distribution of scholarly publications among academic radiology departments.

    Science.gov (United States)

    Morelli, John N; Bokhari, Danial

    2013-03-01

    The aim of this study was to determine whether the distribution of publications among academic radiology departments in the United States is Gaussian (ie, the bell curve) or Paretian. The search affiliation feature of the PubMed database was used to search for publications in 3 general radiology journals with high Impact Factors, originating at radiology departments in the United States affiliated with residency training programs. The distribution of the number of publications among departments was examined using χ(2) test statistics to determine whether it followed a Pareto or a Gaussian distribution more closely. A total of 14,219 publications contributed since 1987 by faculty members in 163 departments with residency programs were available for assessment. The data acquired were more consistent with a Pareto (χ(2) = 80.4) than a Gaussian (χ(2) = 659.5) distribution. The mean number of publications for departments was 79.9 ± 146 (range, 0-943). The median number of publications was 16.5. The majority (>50%) of major radiology publications from academic departments with residency programs originated in Pareto rather than a normal distribution. Copyright © 2013 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  2. Picture archiving and communication systems in radiology

    International Nuclear Information System (INIS)

    Piqueras Pardellans, J.; Carreno Pedemonte, J.C.; Lucaya Layret, J.

    1994-01-01

    Picture archiving and communication systems (PACS) constitute a data processing tool that offers new working methods of diagnostic radiology. The definitive aim of a PACS is to allow a radiology service to operate without film images or documents on paper, integrating images and clinical information. Different image acquisition, viewing and storage systems, linked by communications networks, are arranged around a central management and storage system. Their components are described and the advantages, drawbacks and limitations are discussed from the technological point of view and considering their impact on health care, while a critical review is provided of the 1993 status of this issue

  3. A Comprehensive Analysis of Authorship in Radiology Journals.

    Science.gov (United States)

    Dang, Wilfred; McInnes, Matthew D F; Kielar, Ania Z; Hong, Jiho

    2015-01-01

    The purpose of our study was to investigate authorship trends in radiology journals, and whether International Committee of Medical Journal Editors (ICMJE) recommendations have had an impact on these trends. A secondary objective was to explore other variables associated with authorship trends. A retrospective, bibliometric analysis of 49 clinical radiology journals published from 1946-2013 was conducted. The following data was exported from MEDLINE (1946 to May 2014) for each article: authors' full name, year of publication, primary author institution information, language of publication and publication type. Microsoft Excel Visual Basics for Applications scripts were programmed to categorize extracted data. Statistical analysis was performed to determine the overall mean number of authors per article over time, impact of ICMJE guidelines, authorship frequency per journal, country of origin, article type and language of publication. 216,271 articles from 1946-2013 were included. A univariate analysis of the mean authorship frequency per year of all articles yielded a linear relationship between time and authorship frequency. The mean number of authors per article in 1946 (1.42) was found to have increased consistently by 0.07 authors/ article per year (R² = 0.9728, Pjournals, country of origin, language of publication and article type. Overall authorship for 49 radiology journals across 68 years has increased markedly with no demonstrated impact from ICMJE guidelines. A higher number of authors per article was seen in articles from: higher impact journals, European and Asian countries, original research type, and those journals who explicitly endorse the ICMJE guidelines.

  4. DOEZOR2: a code to assess the radiological impact of effluent discharges

    International Nuclear Information System (INIS)

    Martin Garcia, J.E.; Gomez Rodriguez, C.A.; Gimeno Blesa, M.E.; GARCIA ACOSTA, F.

    2010-01-01

    DOEZOR2 (DOsis al Exterior en ZORita v. 2) comprises a suite of models and data management tools which can be used to perform the radiological impact assessments of routine and continuous discharges from nuclear power plants and nuclear fuel cycle facilities for regulatory purposes. The Code is based on Radiation Protection 72 and the Regulatory Guide 1.109 (USNRC) methodology. The code development was carried out by SOCOIN (Gas Natural Fenosa Group) and is implemented in Jose Cabrera NPP (or Zorita NPP). DOEZOR has been operating during ten years and is about to be updated in order to consider realistic doses methodology. The new software differs from its predecessor in a number of ways, including a new user interface, new radionuclides and several new capacities (realistic dose). The model is developed to estimate radiological consequences of emissions from nuclear power plants. Internal exposure via inhalation and ingestion, external exposure from clouds and radioactivity deposited on the ground are included in the model. DOEZOR2 has been developed in Visual Fortran, using user friendly windows environment and modular architecture (easy to implement for other uses and installations). The main features of the code include: - Annual discharge to the atmospheric or river environment can be modelled. - Dynamic systems dispersion of radionuclides released to the river (two reservoirs). - A comprehensive list of exposure pathways. - A suite of environmental transfer models to estimate the transfer of radionuclides through the environment. - Site specific data (parameters of life habits). - Results in terms of individual doses (three age's groups), using effective dose as defined in Council Directive 96/29/EURATOM and dose coefficients from U.S. Federal Guidance Report 13. - Results in 'MS Word form' for periodic information to authorities. This software could be implemented anywhere, considering the particular characteristic of the site for the plant or facility

  5. Integrating the Radiology Information System with Computerised Provider Order Entry: The Impact on Repeat Medical Imaging Investigations.

    Science.gov (United States)

    Vecellio, Elia; Georgiou, Andrew

    2016-01-01

    Repeat and redundant procedures in medical imaging are associated with increases in resource utilisation and labour costs. Unnecessary medical imaging in some modalities, such as X-Ray (XR) and Computed Tomography (CT) is an important safety issue because it exposes patients to ionising radiation which can be carcinogenic and is associated with higher rates of cancer. The aim of this study was to assess the impact of implementing an integrated Computerised Provider Order Entry (CPOE)/Radiology Information System (RIS)/Picture Archiving and Communications System (PACS) system on the number of XR and CT imaging procedures (including repeat imaging requests) for inpatients at a large metropolitan hospital. The study found that patients had an average 0.47 fewer XR procedures and 0.07 fewer CT procedures after the implementation of the integrated system. Part of this reduction was driven by a lower rate of repeat procedures: the average inpatient had 0.13 fewer repeat XR procedures within 24-hours of the previous identical XR procedure. A similar decrease was not evident for repeat CT procedures. Reduced utilisation of imaging procedures (especially those within very short intervals from the previous identical procedure, which are more likely to be redundant) has implications for the safety of patients and the cost of medical imaging services.

  6. Radiology

    International Nuclear Information System (INIS)

    Edholm, P.R.

    1990-01-01

    This is a report describing diagnostic techniques used in radiology. It describes the equipment necessary for, and the operation of a radiological department. Also is described the standard methods used in radiodiagnosis. (K.A.E.)

  7. Radiological environmental risk associated with different water management systems in amang processing in Malaysia

    International Nuclear Information System (INIS)

    Ismail, B.; Yasir, M.S.; Redzuwan, Y.; Amran, A.M.

    2003-01-01

    The processing of amang (tin-tailing) for its valuable minerals have shown that it technologically enhanced naturally occurring radioactive materials, and has a potential of impacting the environment. Large volume of water is used to extract these valuable minerals from amang. Three types of water management systems are used by amang plants, i.e. Open Water System (OWS), Close Water System Man-made (CWS mm) and Close Water System Natural (CWSn). A study was carried out to determine the radiological environmental risk associated with these different water management systems in amang processing in Malaysia. The parameters studied were pH of water, Water Quality Indices, and uranium ad thorium concentrations in water and sediments. Three different sampling locations were selected for each water management system, i.e. the source, the receiver and related reference water bodies. Results obtained showed that amang reduces the pH and contaminates the water. However, OWS appears have the least radiological environmental impact. On the contrary both CWS (man-made and natural) pose a potential environmental risk if great care are not given to the treatment of accumulated sediment and contaminated water before discharge into the environment

  8. Consequence Assessment for Potential Scenarios of Radiological Terrorists Events

    International Nuclear Information System (INIS)

    Shin, Hyeongki; Kim, Juyoul

    2007-01-01

    Radiological dispersal device (RDD) means any method used to deliberately disperse radioactive material to create terror or harm. Dirty bomb is an example of RDD, which usually consists of radioactive material and unconventional explosive. Dirty bomb was a problem long before September 11, 2001. In 1987, the Iraqi government tested a one-ton radiological bomb. The Iraqi tests confirmed that a dirty bomb is not effective as weapons of mass destruction (WMD) and that its main value is as a psychological weapon. In 1995, Chechen rebels buried a dirty bomb in a park in Moscow threatening to detonate one in the future if their demands were not met. Another good example of potential dirty bomb effects was an incident in Goiania, Brazil on September 18, 1987, where an orphaned medical source containing 1,375 Ci of Cs-137 resulted the death of four people and extensive environmental contamination. The purposes of radiological terrorists events are not to destroy or damage the target but to disperse radioactivity in the environment. They inflict panic on a public and economic damage by disruption of business. They also have influence on enormous clean-up costs by spreading radioactive contamination including secondary impacts on water supply reservoirs. Generally, two major long-term concerns following a RDD are human health and economic impacts. In this study, we developed potential scenarios of radiological terrorists events and performed their radiological consequence assessments in terms of total effective dose equivalent (TEDE), projected cumulative external and internal dose, and ground deposition of radioactivity

  9. Consequence Assessment for Potential Scenarios of Radiological Terrorists Events

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Hyeongki [Korea Institute of Nuclear Safety, Daejeon (Korea, Republic of); Kim, Juyoul [Seoul National University, Seoul (Korea, Republic of)

    2007-07-01

    Radiological dispersal device (RDD) means any method used to deliberately disperse radioactive material to create terror or harm. Dirty bomb is an example of RDD, which usually consists of radioactive material and unconventional explosive. Dirty bomb was a problem long before September 11, 2001. In 1987, the Iraqi government tested a one-ton radiological bomb. The Iraqi tests confirmed that a dirty bomb is not effective as weapons of mass destruction (WMD) and that its main value is as a psychological weapon. In 1995, Chechen rebels buried a dirty bomb in a park in Moscow threatening to detonate one in the future if their demands were not met. Another good example of potential dirty bomb effects was an incident in Goiania, Brazil on September 18, 1987, where an orphaned medical source containing 1,375 Ci of Cs-137 resulted the death of four people and extensive environmental contamination. The purposes of radiological terrorists events are not to destroy or damage the target but to disperse radioactivity in the environment. They inflict panic on a public and economic damage by disruption of business. They also have influence on enormous clean-up costs by spreading radioactive contamination including secondary impacts on water supply reservoirs. Generally, two major long-term concerns following a RDD are human health and economic impacts. In this study, we developed potential scenarios of radiological terrorists events and performed their radiological consequence assessments in terms of total effective dose equivalent (TEDE), projected cumulative external and internal dose, and ground deposition of radioactivity.

  10. The radiological impact of the Belgian phosphate industry

    Energy Technology Data Exchange (ETDEWEB)

    Vanmarcke, H.; Paridaens, J. [Belgian Nuclear Research Centre, SCK.CEN, Boeretang 200, 2400 Mol (Belgium)

    2006-07-01

    The Belgian phosphate industry processes huge amounts of phosphate ore (1.5 to 2 Mton/year) for a wide range of applications, the most important being the production of phosphoric acid, fertilizers and cattle food. Marine phosphate ores show high specific activities of the natural uranium decay series (usually indicated by Ra-226) (e.g. 1200 to 1500 Bq/kg for Moroccan ore). Ores of magmatic origin generally contain less of the uranium and more of the thorium decay series (up to 500 Bq/kg). These radionuclides turn up in by-products, residues or product streams depending on the processing method and the acid used for the acidulation of the phosphate rock. Sulfuric acid is the most widely used, but also hydrochloric acid and nitric acid are applied in Belgium. For Flanders, the northern part of Belgium, we already have a clear idea of the production processes and waste streams. The five Flemish phosphate plants, from 1920 to 2000, handled 54 million ton of phosphate ore containing 65 TBq of radium-226 and 2.7 TBq of thorium- 232. The total surface area of the phosphogypsum and calcium fluoride sludge deposits amounts to almost 300 ha. There is also environmental contamination along two small rivers receiving the waste waters of the hydrochloric production process: the Winterbeek (> 200 ha) and the Grote Laak (12 ha). The data on the impact of the phosphate industry in the Walloon provinces in Belgium is less complete. A large plant produced in 2004 0.8 Mton of phosphogypsum, valorizing about 70 % of the gypsum in building materials (plaster, cement), in fertilizers, and in other products such as paper. The remainder was stored on a local disposal site. The radiological impact of the Belgian phosphate industry on the local population will be discussed. At present most contaminated areas are still recognizable as waste deposits and inaccessible to the population. However as gypsum deposits and other contaminated areas quickly blend in with the landscape, it is

  11. Radiological protection criteria risk assessments for waste disposal options

    International Nuclear Information System (INIS)

    Hill, M.D.

    1982-01-01

    Radiological protection criteria for waste disposal options are currently being developed at the National Radiological Protection Board (NRPB), and, in parallel, methodologies to be used in assessing the radiological impact of these options are being evolved. The criteria and methodologies under development are intended to apply to all solid radioactive wastes, including the high-level waste arising from reprocessing of spent nuclear fuel (because this waste will be solidified prior to disposal) and gaseous or liquid wastes which have been converted to solid form. It is envisaged that the same criteria will be applied to all solid waste disposal options, including shallow land burial, emplacement on the ocean bed (sea dumping), geological disposal on land and sub-seabed disposal

  12. Artificial intelligence in radiology.

    Science.gov (United States)

    Hosny, Ahmed; Parmar, Chintan; Quackenbush, John; Schwartz, Lawrence H; Aerts, Hugo J W L

    2018-05-17

    Artificial intelligence (AI) algorithms, particularly deep learning, have demonstrated remarkable progress in image-recognition tasks. Methods ranging from convolutional neural networks to variational autoencoders have found myriad applications in the medical image analysis field, propelling it forward at a rapid pace. Historically, in radiology practice, trained physicians visually assessed medical images for the detection, characterization and monitoring of diseases. AI methods excel at automatically recognizing complex patterns in imaging data and providing quantitative, rather than qualitative, assessments of radiographic characteristics. In this Opinion article, we establish a general understanding of AI methods, particularly those pertaining to image-based tasks. We explore how these methods could impact multiple facets of radiology, with a general focus on applications in oncology, and demonstrate ways in which these methods are advancing the field. Finally, we discuss the challenges facing clinical implementation and provide our perspective on how the domain could be advanced.

  13. Radiological impact of the management of radioactive waste arising from the Argentine Nuclear Programme

    International Nuclear Information System (INIS)

    Migliori de Beninson, A.; Cancio, D.

    1984-01-01

    The Argentine nuclear programme, as it stands at present, provides for the construction of four nuclear power plants in addition to those of Atucha I and Embalse and for the establishment of such fuel cycle facilities as are required to supply all of these plants. This paper evaluates the radiological impact (collective dose commitment) expected from the management of the radioactive wastes arising in the facilities mentioned above throughout the useful life of the reactors. The maximum individual doses to be expected as a result of the planned high-level-waste repository are also estimated. The evaluations presented are partly specific to the sites under consideration, but they also include estimates of the total collective dose commitments resulting from the management of radioactive waste under the Argentine nuclear programme. (author)

  14. Interventional Radiology of Male Varicocele: Current Status

    International Nuclear Information System (INIS)

    Iaccarino, Vittorio; Venetucci, Pietro

    2012-01-01

    Varicocele is a fairly common condition in male individuals. Although a minor disease, it may cause infertility and testicular pain. Consequently, it has high health and social impact. Here we review the current status of interventional radiology of male varicocele. We describe the radiological anatomy of gonadal veins and the clinical aspects of male varicocele, particularly the physical examination, which includes a new clinical and ultrasound Doppler maneuver. The surgical and radiological treatment options are also described with the focus on retrograde and antegrade sclerotherapy, together with our long experience with these procedures. Last, we compare the outcomes, recurrence and persistence rates, complications, procedure time and cost-effectiveness of each method. It clearly emerges from this analysis that there is a need for randomized multicentre trials designed to compare the various surgical and percutaneous techniques, all of which are aimed at occlusion of the anterior pampiniform plexus.

  15. Interventional Radiology of Male Varicocele: Current Status

    Energy Technology Data Exchange (ETDEWEB)

    Iaccarino, Vittorio, E-mail: vittorio.iaccarino@unina.it; Venetucci, Pietro [University of Naples ' Federico II' , Diagnostic Imaging Department-Cardiovascular and Interventional Radiology, School of Medicine (Italy)

    2012-12-15

    Varicocele is a fairly common condition in male individuals. Although a minor disease, it may cause infertility and testicular pain. Consequently, it has high health and social impact. Here we review the current status of interventional radiology of male varicocele. We describe the radiological anatomy of gonadal veins and the clinical aspects of male varicocele, particularly the physical examination, which includes a new clinical and ultrasound Doppler maneuver. The surgical and radiological treatment options are also described with the focus on retrograde and antegrade sclerotherapy, together with our long experience with these procedures. Last, we compare the outcomes, recurrence and persistence rates, complications, procedure time and cost-effectiveness of each method. It clearly emerges from this analysis that there is a need for randomized multicentre trials designed to compare the various surgical and percutaneous techniques, all of which are aimed at occlusion of the anterior pampiniform plexus.

  16. Radiology research in mainland China in the past 10 years: a survey of original articles published in Radiology and European Radiology

    International Nuclear Information System (INIS)

    Zhang, Long Jiang; Wang, Yun Fei; Yang, Zhen Lu; Lu, Guang Ming; Schoepf, U.J.; Xu, Jiaqian; Li, Enzhong

    2017-01-01

    To evaluate the features and trends of Radiology research in Mainland China through bibliometric analysis of the original articles published in Radiology and European Radiology (ER) between 2006 and 2015. We reviewed the original articles published in Radiology and ER between 2006 and 2015. The following information was abstracted: imaging subspecialty, imaging technique(s) used, research type, sample size, study design, statistical analysis, study results, funding declarations, international collaborations, number of authors, department and province of the first author. All variables were examined longitudinally over time. Radiology research in Mainland China saw a substantial increase in original research articles published, especially in the last 5 years (P < 0.001). Within Mainland China's Radiology research, neuroradiology, vascular/interventional Radiology, and abdominal Radiology were the most productive fields; MR imaging was the most used modality, and a distinct geographic provenience was observed for articles published in Radiology and ER. Radiology research in Mainland China has seen substantial growth in the past 5 years with neuroradiology, vascular/interventional Radiology, and abdominal Radiology as the most productive fields. MR imaging is the most used modality. Article provenience shows a distinct geographical pattern. (orig.)

  17. Radiology research in mainland China in the past 10 years: a survey of original articles published in Radiology and European Radiology

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Long Jiang; Wang, Yun Fei; Yang, Zhen Lu; Lu, Guang Ming [Medical School of Nanjing University, Department of Medical Imaging, Jinling Hospital, Nanjing, Jiangsu (China); Schoepf, U.J. [Medical School of Nanjing University, Department of Medical Imaging, Jinling Hospital, Nanjing, Jiangsu (China); Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States); Xu, Jiaqian [Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States); Li, Enzhong [National Natural Science Foundation of China, Department of Medical Science, Beijing (China)

    2017-10-15

    To evaluate the features and trends of Radiology research in Mainland China through bibliometric analysis of the original articles published in Radiology and European Radiology (ER) between 2006 and 2015. We reviewed the original articles published in Radiology and ER between 2006 and 2015. The following information was abstracted: imaging subspecialty, imaging technique(s) used, research type, sample size, study design, statistical analysis, study results, funding declarations, international collaborations, number of authors, department and province of the first author. All variables were examined longitudinally over time. Radiology research in Mainland China saw a substantial increase in original research articles published, especially in the last 5 years (P < 0.001). Within Mainland China's Radiology research, neuroradiology, vascular/interventional Radiology, and abdominal Radiology were the most productive fields; MR imaging was the most used modality, and a distinct geographic provenience was observed for articles published in Radiology and ER. Radiology research in Mainland China has seen substantial growth in the past 5 years with neuroradiology, vascular/interventional Radiology, and abdominal Radiology as the most productive fields. MR imaging is the most used modality. Article provenience shows a distinct geographical pattern. (orig.)

  18. Radioactive characterization of the main materials involved in the titanium dioxide production process and their environmental radiological impact.

    Science.gov (United States)

    Mantero, J; Gazquez, M J; Bolivar, J P; Garcia-Tenorio, R; Vaca, F

    2013-06-01

    A study about the distribution of several radionuclides from the uranium and the thorium series radionuclides along the production process of a typical NORM industry devoted to the production of titanium dioxide has been performed. With this end the activity concentrations in raw materials, final product, co-products, and wastes of the production process have been determined by both gamma-ray and alpha-particle spectrometry. The main raw material used in the studied process (ilmenite) presents activity concentrations of around 300 Bq kg(-1) for Th-series radionuclides and 100 Bq kg(-1) for the U-series ones. These radionuclides in the industrial process are distributed in the different steps of the production process according mostly to the chemical behaviour of each radioelement, following different routes. As an example, most of the radium remains associated with the un-dissolved material waste, with activity concentrations around 3 kBq kg(-1) of (228)Ra and around 1 kBq kg(-1) of (226)Ra, while the final commercial products (TiO2 pigments and co-products) contain negligible amounts of radioactivity. The obtained results have allowed assessing the possible public radiological impact associated with the use of the products and co-products obtained in this type of industry, as well as the environmental radiological impact associated with the solid residues and liquid generated discharges. Copyright © 2013 Elsevier Ltd. All rights reserved.

  19. The clinical impact of the radiology report in wheezing and nonwheezing febrile children: a survey of clinicians

    International Nuclear Information System (INIS)

    Spottswood, Stephanie E.; Hernanz-Schulman, Marta; Hilmes, Melissa A.; Kan, J.H.; Liaw, Kevin; Moore, Paul E.; Patterson, Barron; Chen, Heidi

    2009-01-01

    The chest radiograph is commonly used in the diagnosis and management of patients presenting with respiratory illness. The language used to describe the findings is important to ensure appropriate communication with the referring clinician and thereby optimize patient management. In this study we attempted to determine how clinicians interpret specific terms commonly used in a chest radiograph report, and to assess how these terms impact the management of children with respiratory symptoms. An online survey was distributed to 562 pediatric practitioners asking their interpretation of the terms ''peripheral airway disease (PAD),'' ''focal airspace consolidation,'' and ''focal infiltrate'' in a febrile child with or without wheezing. There were 112 respondents. Most practitioners defined the term ''PAD'' as viral pneumonia (61.5%) or asthma (56.9%), ''consolidation'' as atelectasis (83%) followed by pneumonia (69.6%), and ''infiltrate'' as pneumonia (100%), followed by atelectasis (22.3%). Practitioners were more likely to treat a nonwheezing child with antibiotics if the report stated ''focal airspace consolidation'' (80%) or ''focal infiltrate'' (100%; P=0.001). Some radiologic descriptors may lead to diverse and sometimes unintended diagnostic conclusions. Our findings support continued effort to structure and standardize the radiology report and our descriptive terminology. (orig.)

  20. Assessment of the radiological control at the IPEN radioisotope production facility

    Energy Technology Data Exchange (ETDEWEB)

    Carneiro, J.C.G.G.; Sanches, M.P.; Rodrigues, D.L.; Campos, D.; Nogueira, P.R.; Damatto, S.R.; Pecequilo, B.R.S. [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2015-07-01

    The main objective of this work is to evaluate the 2013 annual radiological control results in the radiopharmaceuticals areas of the Nuclear and Energy Research Institute, IPEN/SP, Brazil and the environmental radiological impact, resulting from the practices there performed. The current evaluation was performed through the analysis of the results obtained from occupational and environmental monitoring with air samplers and TL dosimeters. All monitoring results were compared with the limits established by national standards. The radionuclides detected by air sampling (in activated carbon cartridges and filter paper) at the workplace during radioisotope production were {sup 131}I, {sup 99m}Tc and {sup 99}Mo, with activities concentrations values below the annual limits values. For the radioactive gaseous releases (Bq/m{sup 3} ), the activities concentrations also remained below the maximum admissible values, excepting to {sup 125}I release due to an unusual event occurred in a researcher laboratory, but the radiological impact to environmental was no significant. The occupational monitoring assessment was confirmed by the Environmental Radiological Monitoring Program results with air samplers and TL dosimeters. The mean annual background radiation at IPEN in 2013, according to the Environmental Radiological Monitoring Program results was 1.06 mSv. y{sup -1} , below the ICRP 103 recommended limit of 20 mSv.y{sup -1} for workers. (author)

  1. Potential radiological impact of the phosphate industry on wildlife

    International Nuclear Information System (INIS)

    Vandenhove, Hildegarde; Vives i Batlle, Jordi; Sweeck, Lieve

    2015-01-01

    The activities of the phosphate industry may lead to enhanced levels of naturally occurring radioactivity in terrestrial and aquatic ecosystems. We performed a preliminary environmental risk assessment (ERA) of environmental contamination resulting from the activities of 5 phosphate fertiliser plants (located in Belgium, Spain, Syria, Egypt, Brazil), a phosphate-mine and a phosphate-export platform in a harbour (both located in Syria). These sites were selected because of the availability of information on concentrations of naturally occurring radionuclides in the surrounding environments. Assessments were generally performed considering highest environmental concentrations reported in the studies. The ERICA Tool, operating in a Tier 2 assessment mode, was used to predict radiation dose rates and associated risk to the selected reference organisms using the ERICA default parameter setting. Reference organisms were those assigned as default by the ERICA Tool. Potential impact is expressed as a best estimate risk quotient (RQ) based on a radiation screening value of 10 μGy h −1 . If RQ ≤ 1, the environment is considered unlikely to be at risk and further radiological assessment is not deemed necessary. Except for one of the cases assessed, the best estimate RQ exceeded 1 for at least one of the reference organisms. Internal exposure covered for 90–100 % of the total dose. 226 Ra or 210 Po were generally the highest contributors to the dose. The aquatic ecosystems in the vicinity of the phosphate fertiliser plants in Tessenderlo (Belgium), Huelva (Spain), Goiás (Brazil) and the terrestrial environment around the phosphate mine in Palmyra (Syria) are the ecosystems predicted to be potentially most at risk. - Highlights: • The adjusted highlights Environmental radionuclide enrichment from P-industry warrants risk assessment. • 226 Ra and 210 Po are the most dose contributing radionuclides. • The total dose rate is strongly driven by the internal

  2. Radioecology teaching: response to a nuclear or radiological emergency

    Science.gov (United States)

    Anjos, R. M.

    2006-03-01

    The study of environmental radioactivity is a topic not usually included in physics courses in Brazilian and Latin American universities. Consequently, high-school teachers rarely have the opportunity to discuss with their students the effects of radioactive contamination in forest and agricultural ecosystems following a nuclear or radiological emergency, or to conduct experiments to illustrate the methodology employed to assess the consequences of such an event. This paper presents a laboratory experiment which could be included as part of a teaching programme on ionizing radiation physics, addressing some of the aspects related to the fate and effects of anthropogenic radionuclides following a radiation emergency, and the possible physical countermeasures that could be adopted in order to reduce their impact on the environment.

  3. Radioecology teaching: response to a nuclear or radiological emergency

    International Nuclear Information System (INIS)

    Anjos, R M

    2006-01-01

    The study of environmental radioactivity is a topic not usually included in physics courses in Brazilian and Latin American universities. Consequently, high-school teachers rarely have the opportunity to discuss with their students the effects of radioactive contamination in forest and agricultural ecosystems following a nuclear or radiological emergency, or to conduct experiments to illustrate the methodology employed to assess the consequences of such an event. This paper presents a laboratory experiment which could be included as part of a teaching programme on ionizing radiation physics, addressing some of the aspects related to the fate and effects of anthropogenic radionuclides following a radiation emergency, and the possible physical countermeasures that could be adopted in order to reduce their impact on the environment

  4. Value-Based Assessment of Radiology Reporting Using Radiologist-Referring Physician Two-Way Feedback System-a Design Thinking-Based Approach.

    Science.gov (United States)

    Shaikh, Faiq; Hendrata, Kenneth; Kolowitz, Brian; Awan, Omer; Shrestha, Rasu; Deible, Christopher

    2017-06-01

    In the era of value-based healthcare, many aspects of medical care are being measured and assessed to improve quality and reduce costs. Radiology adds enormously to health care costs and is under pressure to adopt a more efficient system that incorporates essential metrics to assess its value and impact on outcomes. Most current systems tie radiologists' incentives and evaluations to RVU-based productivity metrics and peer-review-based quality metrics. In a new potential model, a radiologist's performance will have to increasingly depend on a number of parameters that define "value," beginning with peer review metrics that include referrer satisfaction and feedback from radiologists to the referring physician that evaluates the potency and validity of clinical information provided for a given study. These new dimensions of value measurement will directly impact the cascade of further medical management. We share our continued experience with this project that had two components: RESP (Referrer Evaluation System Pilot) and FRACI (Feedback from Radiologist Addressing Confounding Issues), which were introduced to the clinical radiology workflow in order to capture referrer-based and radiologist-based feedback on radiology reporting. We also share our insight into the principles of design thinking as applied in its planning and execution.

  5. Radiological protection at particle accelerators: An overview

    International Nuclear Information System (INIS)

    Thomas, R.H.

    1991-01-01

    Radiological protection began with particle accelerators. Many of the concerns in the health physics profession today were discovered at accelerator laboratories. Since the mid-1940s, our understanding has progressed through seven stages: observation of high radiation levels; shielding; development of dosimetric techniques; studies of induced activity and environmental impact; legislative and regulatory concerns; and disposal. The technical and scientific aspects of accelerator radiation safety are well in hand. In the US, there is an urgent need to move away from a ''best available technology'' philosophy to risk-based health protection standards. The newer accelerators will present interesting radiological protection issues, including copious muon production and high LET (neutron) environments

  6. The accuracy of radiology speech recognition reports in a multilingual South African teaching hospital

    International Nuclear Information System (INIS)

    Toit, Jacqueline du; Hattingh, Retha; Pitcher, Richard

    2015-01-01

    Speech recognition (SR) technology, the process whereby spoken words are converted to digital text, has been used in radiology reporting since 1981. It was initially anticipated that SR would dominate radiology reporting, with claims of up to 99% accuracy, reduced turnaround times and significant cost savings. However, expectations have not yet been realised. The limited data available suggest SR reports have significantly higher levels of inaccuracy than traditional dictation transcription (DT) reports, as well as incurring greater aggregate costs. There has been little work on the clinical significance of such errors, however, and little is known of the impact of reporter seniority on the generation of errors, or the influence of system familiarity on reducing error rates. Furthermore, there have been conflicting findings on the accuracy of SR amongst users with English as first- and second-language respectively. The aim of the study was to compare the accuracy of SR and DT reports in a resource-limited setting. The first 300 SR and the first 300 DT reports generated during March 2010 were retrieved from the hospital’s PACS, and reviewed by a single observer. Text errors were identified, and then classified as either clinically significant or insignificant based on their potential impact on patient management. In addition, a follow-up analysis was conducted exactly 4 years later. Of the original 300 SR reports analysed, 25.6% contained errors, with 9.6% being clinically significant. Only 9.3% of the DT reports contained errors, 2.3% having potential clinical impact. Both the overall difference in SR and DT error rates, and the difference in ‘clinically significant’ error rates (9.6% vs. 2.3%) were statistically significant. In the follow-up study, the overall SR error rate was strikingly similar at 24.3%, 6% being clinically significant. Radiologists with second-language English were more likely to generate reports containing errors, but level of seniority

  7. Radioactive Waste Management Complex low-level waste radiological performance assessment

    Energy Technology Data Exchange (ETDEWEB)

    Maheras, S.J.; Rood, A.S.; Magnuson, S.O.; Sussman, M.E.; Bhatt, R.N.

    1994-04-01

    This report documents the projected radiological dose impacts associated with the disposal of radioactive low-level waste at the Radioactive Waste Management Complex at the Idaho National Engineering Laboratory. This radiological performance assessment was conducted to evaluate compliance with applicable radiological criteria of the US Department of Energy and the US Environmental Protection Agency for protection of the public and the environment. The calculations involved modeling the transport of radionuclides from buried waste, to surface soil and subsurface media, and eventually to members of the public via air, groundwater, and food chain pathways. Projections of doses were made for both offsite receptors and individuals inadvertently intruding onto the site after closure. In addition, uncertainty and sensitivity analyses were performed. The results of the analyses indicate compliance with established radiological criteria and provide reasonable assurance that public health and safety will be protected.

  8. Radioactive Waste Management Complex low-level waste radiological performance assessment

    International Nuclear Information System (INIS)

    Maheras, S.J.; Rood, A.S.; Magnuson, S.O.; Sussman, M.E.; Bhatt, R.N.

    1994-04-01

    This report documents the projected radiological dose impacts associated with the disposal of radioactive low-level waste at the Radioactive Waste Management Complex at the Idaho National Engineering Laboratory. This radiological performance assessment was conducted to evaluate compliance with applicable radiological criteria of the US Department of Energy and the US Environmental Protection Agency for protection of the public and the environment. The calculations involved modeling the transport of radionuclides from buried waste, to surface soil and subsurface media, and eventually to members of the public via air, groundwater, and food chain pathways. Projections of doses were made for both offsite receptors and individuals inadvertently intruding onto the site after closure. In addition, uncertainty and sensitivity analyses were performed. The results of the analyses indicate compliance with established radiological criteria and provide reasonable assurance that public health and safety will be protected

  9. Integrated manure management to reduce environmental impact: II. Environmental impact assessment of strategies

    NARCIS (Netherlands)

    Vries, de J.W.; Groenestein, C.M.; Schroder, J.J.; Hoogmoed, W.B.; Sukkel, W.; Groot Koerkamp, P.W.G.; Boer, de I.J.M.

    2015-01-01

    Manure management contributes to adverse environmental impacts through losses of nitrogen (N), phosphorus, and carbon (C). In this study, we aimed to assess the potential of newly designed strategies for integrated manure management (IS) to reduce environmental impact. An important aspect of the

  10. Refractory of Furnaces to Reduce Environmental Impact

    International Nuclear Information System (INIS)

    Hanzawa, Shigeru

    2011-01-01

    The energy load of furnaces used in the manufacturing process of ceramics is quite large. Most of the environmental impact of ceramics manufacturing is due to the CO 2 produced from this high energy load. To improve this situation, R and D has focused on furnace systems and techniques of control in order to reduce energy load. Since furnaces are comprised of refractory, consideration of their mechanical and thermal characteristics is important. Herein are described several refractory types which were chosen through comparison of the characteristics which contribute to heat capacity reduction, heat insulating reinforcement and high emissivity, thereby improving thermal radiation heat transfer efficiency to the ceramic articles. One selected refractory material which will reduce the environmental impact of a furnace, chosen considering low heat capacity and high emissivity characteristics, is SiC. In this study, thermal radiation heat transfer efficiency improvement and its effect on ceramic articles in the furnace and oxidation behaviour were investigated at 1700K. A high density SiC refractory, built into the furnace at construction, has relatively high oxidation durability and has the ability to reduce environmental impact-CO 2 by 10 percent by decreasing the furnace's energy load. However, new oxidation prevention techniques for SiC will be necessary for long-term use in industrial furnaces, because passive to active oxidation transition behaviour of commercial SiC refractory is coming to close ideal.

  11. Refractory of Furnaces to Reduce Environmental Impact

    Science.gov (United States)

    Hanzawa, Shigeru

    2011-10-01

    The energy load of furnaces used in the manufacturing process of ceramics is quite large. Most of the environmental impact of ceramics manufacturing is due to the CO2 produced from this high energy load. To improve this situation, R&D has focused on furnace systems and techniques of control in order to reduce energy load. Since furnaces are comprised of refractory, consideration of their mechanical and thermal characteristics is important. Herein are described several refractory types which were chosen through comparison of the characteristics which contribute to heat capacity reduction, heat insulating reinforcement and high emissivity, thereby improving thermal radiation heat transfer efficiency to the ceramic articles. One selected refractory material which will reduce the environmental impact of a furnace, chosen considering low heat capacity and high emissivity characteristics, is SiC. In this study, thermal radiation heat transfer efficiency improvement and its effect on ceramic articles in the furnace and oxidation behaviour were investigated at 1700K. A high density SiC refractory, built into the furnace at construction, has relatively high oxidation durability and has the ability to reduce environmental impact-CO2 by 10 percent by decreasing the furnace's energy load. However, new oxidation prevention techniques for SiC will be necessary for long-term use in industrial furnaces, because passive to active oxidation transition behaviour of commercial SiC refractory is coming to close ideal.

  12. Radiological impact of the future CERN program (LEP)

    International Nuclear Information System (INIS)

    Goebel, K.

    1982-01-01

    The author discusses the radiation problems which are the radiological influences of LEP which interest the majority of the members of the personnel. The first studies done in this domain are achieved, and the results are published this summer, among others the doses of radiation and of radioactivity and equally the concentration of hoxions gases on the exterior of the enclosure of future installations. The results are the object of discussions and are compared with the norms of radioprotection and with the actual situation in this region. (orig.)

  13. Radiological protection and environmental management

    International Nuclear Information System (INIS)

    Perez Fonseca, A.

    2010-01-01

    From the beginning of its industrial activity twenty five years ago, the Juzbado Factory of Enusa Group has always upheld a strong commitment with Radiological Protection and environmental respect and protection. Consequently, the evolution of dose shows a downward trend over the years. Although production has been increased gradually, the average doses to workers have stayed below 1 mSv. In order to identify and prevent the potential environmental impacts of its industrial activity and minimize its impact on the surroundings, the facility develops and environmental management system according to UNE-EN-ISO 14001 since 1999. (Author)

  14. General Employee Radiological Training and Radiological Worker Training: Program management manual

    International Nuclear Information System (INIS)

    1992-10-01

    This manual defines and describes the DOE General Employee Radiological Training (GERT) and Radiological Worker I and II (RW I and II) Training programs. It includes material development requirements, standards and policies, and program administration. This manual applies to General Employee Radiological Training and Radiological Worker Training at all DOE contractor sites. The training materials of both GERT and RW I and II training reflect the requirements identified in the DOE Radiological Control Manual and DOE Order 5480.11. The training programs represent the minimum requirement for the standardized core materials. Each contractor shall implement the program in its entirety and may augment the standardized core materials to increase the general employee and radiological worker level of competency

  15. Hotspot health physics codes used as a tool for managing excess risk on radiological emergencies

    International Nuclear Information System (INIS)

    Andrade, Edson Ramos de; Alves, Nelson Mendes; Rocha, Joao B.T.; Cruz, Ivana B. Manica da; Santos, Greice F. Fey dos; Machado, Michel Mansur; Rossato, Veronica Venturini; Bauermann, Liliane Freitas

    2008-01-01

    This work is aimed to use the Hotspot Health Physics codes in acute mode in order to estimate the immediate radiological impact associated with high acute radiation doses, which is applied to special target organs such as lung, small intestine wall, and red bone marrow. Organic compounds such as Diphenyl Diselenide (C 6 H 5 Se 2 C 6 H 5 ) and Ebselen (C 13 H 9 NOSe), an antioxidants selenium containing compounds, were used over irradiated phospholipids extracted from chicken yolk eggs, in vitro in order to reduce lipo-peroxidation. Experimental data were measured by Thiobarbituric Acid Reactive Substance (TBARS) assay which is able to measure the production of oxidative stress in the sample. Experimental data were extrapolated and applied as a reduction factors over equations for cancer excess risk calculation from BEIR V, for helping the decisonmaking process on Radiological Emergency Scenarios. (author)

  16. Auditor recommendations resulting from three clinical audit rounds in Finnish radiology units.

    Science.gov (United States)

    Miettunen, Kirsi; Metsälä, Eija

    2017-06-01

    Background The purpose of clinical audits performed in radiology units is to reduce the radiation dose of patients and staff and to implement evidence-based best practices. Purpose To describe auditor recommendations in three Finnish clinical audit rounds performed in 2002-2014, and to determine if auditor recommendations have had any impact on improving medical imaging practice. Material and Methods The retrospective observational study was performed in radiology units holding a radiation safety license issued by the Finnish Radiation and Nuclear Safety Authority. The data comprised a systematic sample (n = 120) of auditor reports produced in three auditing rounds in these units during the years 2002-2014. The data were analyzed by descriptive methods and by using the Friedman two-way ANOVA test. Results The number of auditor recommendations given varied between clinical audit rounds and according to the type of imaging unit, as well as according to calculation method. Proportionally, the most recommendations in all three clinical audit rounds were given about defining and using quality assurance functions and about guidelines and practices for carrying out procedures involving radiation exposure. Demanding radiology units improved their practices more than basic imaging units towards the third round. Conclusion Auditor recommendations help to address the deficiencies in imaging practices. There is a need to develop uniform guidelines and to provide tutoring for clinical auditors in order to produce comparable clinical audit results.

  17. Coal-fired power stations - the radiological impact of effluent discharges to atmosphere

    International Nuclear Information System (INIS)

    Camplin, W.C.

    1980-06-01

    An assessment is made of the radiological impact of atmosphere discharges from a hypothetical 2000 MWe power station sited in Great Britain. The exposure pathways considered are external irradiation from the plume and from activity deposited on the ground, inhalation of material in the plume and material resuspended from land surfaces, and ingestion of contaminated foodstuffs. The reduction in radiation exposure due to naturally-occurring 14 C by releases of stable carbon from the power station is also considered. The ingestion pathway is found to result in the highest individual doses, whereas the inhalation pathway makes the dominant contribution to collective dose. The most important radionuclides are 210 Pb, 210 Po and the thorium isotopes 232 Th, 230 Th and 228 Th. For 30 years operation of the power-station, the collective effective dose equivalent commitment truncated to 500 years is estimated to be 340 man Sv. The maximum annual committed effective dose equivalent to an individual is evaluated as 230 μSv, though it is considered improbable that this level of dose would be found in practice. (author)

  18. Control of radiological impacts in deactivated uranium mine - the portuguese experience; Controlo dos impactes radiologicos em minas de uranio desactivadas - a experiencia portuguesa

    Energy Technology Data Exchange (ETDEWEB)

    Pereira, Alcides; Neves, Luis, E-mail: apereira@dct.uc.p, E-mail: luis.neves@dct.uc.p [Universidade de Coimbra (Portugal). Dept. de Ciencias da Terra. Instituto do Mar

    2011-10-26

    The exploration of radioactive ores occurred in Portugal during around 100 years, and on that period 4370 tons were produced of uranium concentrate, and an estimated total of 13 millions of tons of residues, of various type and variable dangerous grade. From the year 2000 that the government has been performed studies on environmental characterization at the mining areas and remediation project as well. The precise evaluation of the environmental impacts implies the the knowledge of prior work situation, nonexistent for the case of Portuguese mines. This work proposes a methodology for exceeding that limitation focused on selection of area sited at the same metallogenetic province, and considered representative of background. The radiological impacts are checked by the effective dose calculated for reference groups of the exposed population, at this region and in the principal mining area at Portugal (Urgeirica), at the end of exploration and after the finalization of some remediation works

  19. Malpractice claims in interventional radiology: frequency, characteristics and protective measures.

    Science.gov (United States)

    Magnavita, N; Fileni, A; Mirk, P; Magnavita, G; Ricci, S; Cotroneo, A R

    2013-04-01

    The use of interventional radiology procedures has considerably increased in recent years, as has the number of related medicolegal litigations. This study aimed to highlight the problems underlying malpractice claims in interventional radiology and to assess the importance of the informed consent process. The authors examined all insurance claims relating to presumed errors in interventional radiology filed by radiologists over a period of 14 years after isolating them from the insurance database of all radiologists registered with the Italian Society of Medical Radiology (SIRM) between 1 January1993 and 31 December 2006. In the period considered, 98 malpractice claims were filed against radiologists who had performed interventional radiology procedures. In 21 cases (21.4%), the event had caused the patient's death. In >80% of cases, the event occurred in a public facility. The risk of a malpractice claim for a radiologist practising interventional procedures is 47 per 1,000, which corresponds to one malpractice claim for each 231 years of activity. Interventional radiology, a discipline with a biological risk profile similar to that of surgery, exposes practitioners to a high risk of medicolegal litigation both because of problems intrinsic to the techniques used and because of the need to operate on severely ill patients with compromised clinical status. Litigation prevention largely depends on both reducing the rate of medical error and providing the patient with correct and coherent information. Adopting good radiological practices, scrupulous review of procedures and efficiency of the instruments used and audit of organisational and management processes are all factors that can help reduce the likelihood of error. Improving communication techniques while safeguarding the patient's right to autonomy also implies adopting clear and rigorous processes for obtaining the patient's informed consent to the medical procedure.

  20. Radiology residents' experience with intussusception reduction

    International Nuclear Information System (INIS)

    Bateni, Cyrus; Stein-Wexler, Rebecca; Wootton-Gorges, Sandra L.; Li, Chin-Shang

    2011-01-01

    Residents should be exposed to adequate procedural volume to act independently upon completion of training. Informal inquiry led us to question whether residents encounter enough intussusception reductions to become comfortable with the procedure. We sought to determine radiology residents' exposure to intussusception reductions, and whether their experiences vary by region or institution. U.S. radiology residency program directors were asked to encourage their residents to complete a 12-question online survey describing characteristics of their pediatric radiology department, experiences with intussusception reduction, and confidence in their own ability to perform the procedure. Six hundred sixty-four residents responded during the study period. Of those, 308 (46.4%) had not experienced an intussusception reduction, and 228 (34%) had experienced only one or two. Twenty-two percent of fourth-year residents had never experienced an intussusception reduction, and 21% had experienced only one. Among second- through fourth-year residents, only 99 (18.3%) felt confident that they could competently reduce an intussusception (P < 0.0001), and 336 (62.2%) thought they would benefit from a computer-assisted training model simulating intussusception reduction (P < 0.0001). Radiology residents have limited opportunity to learn intussusception reduction and therefore lack confidence. Most think they would benefit from additional training with a computer-simulation model. (orig.)

  1. Leveraging Twitter to Maximize the Radiology Meeting Experience.

    Science.gov (United States)

    Kalia, Vivek; Ortiz, Daniel A; Patel, Amy K; Moriarity, Andrew K; Canon, Cheri L; Duszak, Richard

    2018-01-01

    Over recent years, social media engagement has proliferated among physicians, health care systems, scientific journals, professional societies, and patients. In radiology, Twitter (Twitter Inc, San Francisco, California) has rapidly become the preferred social media engagement tool and is now an essential activity at many large radiology society meetings. Twitter offers a versatile, albeit simple, platform for anyone interested in engaging with others, regardless of title, stature, or geography. In radiology and other medical specialties, year-after-year increases in Twitter engagement before, during, and after professional society meetings continue with widespread positive feedback. This short-form messaging tool also allows users to connect and interact with high-impact individuals and organizations on an ongoing basis (rather than once a year during large meetings). Through live-polling, Twitter also has the power to gather global opinions on issues highly relevant to radiology's future, such as the Medicare Access and CHIP Reauthorization Act of 2015 (MACRA) or breast cancer screening. Also increasingly popular is "live-tweeting" of curated meeting content, which makes information from the meeting accessible to a global audience. Despite the promise of growing professional networks and enabling discussions that cross geographic boundaries, the risks of Twitter use during radiology meetings must be recognized and mitigated. These include posting of unpublished data without consent (eg, slide content captured on camera phones), propagation of misinformation, and copyright infringement. Despite these issues and with an eye towards professionalism, Twitter can nonetheless be used effectively to increase engagement among radiologists, radiology societies, and patients. Copyright © 2017 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  2. Evaluation of the atmospheric stability and it influence in the radiological environmental impact of the treatment plant and radioactive waste storage (PTDR); Evaluacion de la estabilidad atmosferica y su influencia en el impacto radiologico ambiental de la planta de tratamiento y almacenamiento de desechos radiactivos (PTDR)

    Energy Technology Data Exchange (ETDEWEB)

    Ramos V, E.O.; Cornejo D, N. [CPHR, Calle 20 No. 4113 e/41 y 47 Playa C.P. 11300, Ciudad Habana (Cuba)]. e-mail: odalys@cphr.edu.cu

    2006-07-01

    It is well-known that the meteorological variables as the atmospheric stability, influence in the atmospheric dispersion of radioactive pollutants, for that as regards radiological safety, it constitutes a demand the evaluation of their impact in the process before mentioned. The present work exposes the results of the study of the radiological impact of our PTDR that it allowed to know the influence of this meteorological parameter in the atmospheric dispersion of radioactive pollutants in its location. To such effects they were processed by means of the methodology of Pasquill - Gifford, data of time zone observations of this meteorological variable obtained in the proximities of the installation, being modeled the worst conditions in atmospheric liberation of their radionuclides inventory, valuing stops the 2 critical considered population groups the doses received by inhalation of polluted air and ingestion of water and polluted products, as well as, for external irradiation from the radioactive cloud and the floor. The obtained annual effective doses due to the modeling situation reach until a mSv, except for the Ra-226 that are lightly superior, implying a risk radiological acceptable chord to the international standard. To the above-mentioned a reduced probability of occurrence of events initiators of the evaluated accidental sequence is added. (Author)

  3. MEMO radiology

    International Nuclear Information System (INIS)

    Wagner-Manslau, C.

    1989-01-01

    This radiology volume is a concise handbook of imaging techniques, nuclear medicine, and radiation therapy, albeit that the main emphasis is on classic radiology. It offers, for instance, a survey of radiological findings for the most frequent pathological conditions, many overviews of differential diagnosis, a glossary of the technical bases of radiology and so forth. The contents are divided into the following chapters: Physical and biological bases; skeleton; thorax with the subdivisions lungs, heart, mediastinum, and pleura; gastrointestinal tract with the subsections esophagus, small and large intestine; liver; biliary tract; pancreas; retroperitoneal space; kidney; suprarenal glands; bladder; blood vessels, lymph nodes, spleen; mammary glands; female genitals; prostate and scrotum, epididymis and seminal vesicle. (orig./MG) With 23 figs [de

  4. The impact of communication materials on public responses to a radiological dispersal device (RDD) attack.

    Science.gov (United States)

    Rogers, M Brooke; Amlôt, Richard; Rubin, G James

    2013-03-01

    It is a common assumption that, in the event of a chemical, biological, radiological, or nuclear (CBRN) attack, a well-prepared and informed public is more likely to follow official recommendations regarding the appropriate safety measures to take. We present findings from a UK study investigating the ability of crisis communication to influence perceptions of risk and behavioral intentions in the general public in response to CBRN terrorism. We conducted a focus group study involving a scenario presented in mock news broadcasts to explore levels of public knowledge, information needs, and intended behavioral reactions to an attack involving an overt radiological dispersal device (RDD), or dirty bomb. We used the findings from these focus groups to design messages for the public that could be presented in a short leaflet. We then tested the effects of the leaflet on reactions to the same scenario in 8 further focus groups. The impact of the new messages on levels of knowledge, information needs, and intended compliance with official recommendations was assessed. The provision of information increased the perceived credibility of official messages and increased reported levels of intended compliance with advice to return to normal/stop sheltering, attend a facility for assessment and treatment, and return to a previously contaminated area after decontamination of the environment has taken place. Should a real attack with an RDD occur, having pretested messages available to address common concerns and information needs should facilitate the public health response to the attack.

  5. Document: the radiological survey of the environment

    International Nuclear Information System (INIS)

    Gerno, Linden; Leprieur, F.; Janssens, A.

    2002-01-01

    The document presents the radiological survey of the environment in France today with a comparison of the situation in Switzerland, Germany and Belgium. The evolution of the policy in this activity is also concerned. The laboratories and their monitoring equipment, the regulation and the social impacts are discussed. (A.L.B.)

  6. Utilization management in radiology, part 2: perspectives and future directions.

    Science.gov (United States)

    Duszak, Richard; Berlin, Jonathan W

    2012-10-01

    Increased utilization of medical imaging in the early part of the last decade has resulted in numerous efforts to reduce associated spending. Recent initiatives have focused on managing utilization with radiology benefits managers and real-time order entry decision support systems. Although these approaches might seem mutually exclusive and their application to radiology appears unique, the historical convergence and broad acceptance of both programs within the pharmacy sector may offer parallels for their potential future in medical imaging. In this second installment of a two-part series, anticipated trends in radiology utilization management are reviewed. Perspectives on current and future potential roles of radiologists in such initiatives are discussed, particularly in light of emerging physician payment models. Copyright © 2012 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  7. Radiological analysis by the addition of hydrogen and noble metals in the reactors of the Laguna Verde central

    International Nuclear Information System (INIS)

    Padilla C, I.

    2006-01-01

    During the operation of the nuclear power stations there are metals that are subject to condition and agents that cause that these they present indications of intergranular corrosion and for their importance they are subject to a continuous surveillance to assure their integrity. During the time of operation, for the level of indications, it can be necessary the substitution of these. The internal components of the vessel and particularly those of the structure of the reactor core are exposed during the operation to a neutron flow that causes that these they are activated and, in consequence, before an eventual repair it will be necessary to face high radiation levels. At the moment a technique that controls exists and it reduces the growth rate of the indications in the metals and it increases its useful life: the addition of hydrogen. The addition of hydrogen it is an ALARA measure from long term when protecting the internals of the vessel that requires to establish radiological controls in the stage of their application to avoid unnecessary dose to the personnel. The addition of hydrogen to the primary system has as objective to reduce the growth of indications taken place by intergranular corrosion in metals of the reactor core and this is achieved when the electrochemical thresholds are reached. Hydrogen to interacting with the metal surfaces it generates reductive reactions causing in consequence an increment in the concentration of soluble cobalt in the coolant one and an increment in the nitrogen concentration. To reduce the magnitude of the radiological impact that in some NC reach up to factors 10, its are injected to the system noble metals as the rhodium and the platinum, to reduce the concentration of hydrogen to the system and to be below the threshold electrochemical potential necessary to protect the internals of the reactor vessel. The external and internal operational experience generated on this protection technique to the internals of the vessel

  8. Radiology and fine art.

    Science.gov (United States)

    Marinković, Slobodan; Stošić-Opinćal, Tatjana; Tomić, Oliver

    2012-07-01

    The radiologic aesthetics of some body parts and internal organs have inspired certain artists to create specific works of art. Our aim was to describe the link between radiology and fine art. We explored 13,625 artworks in the literature produced by 2049 artists and found several thousand photographs in an online image search. The examination revealed 271 radiologic artworks (1.99%) created by 59 artists (2.88%) who mainly applied radiography, sonography, CT, and MRI. Some authors produced radiologic artistic photographs, and others used radiologic images to create artful compositions, specific sculptures, or digital works. Many radiologic artworks have symbolic, metaphoric, or conceptual connotations. Radiology is clearly becoming an original and important field of modern art.

  9. Improving financial performance by modeling and analysis of radiology procedure scheduling at a large community hospital.

    Science.gov (United States)

    Lu, Lingbo; Li, Jingshan; Gisler, Paula

    2011-06-01

    Radiology tests, such as MRI, CT-scan, X-ray and ultrasound, are cost intensive and insurance pre-approvals are necessary to get reimbursement. In some cases, tests may be denied for payments by insurance companies due to lack of pre-approvals, inaccurate or missing necessary information. This can lead to substantial revenue losses for the hospital. In this paper, we present a simulation study of a centralized scheduling process for outpatient radiology tests at a large community hospital (Central Baptist Hospital in Lexington, Kentucky). Based on analysis of the central scheduling process, a simulation model of information flow in the process has been developed. Using such a model, the root causes of financial losses associated with errors and omissions in this process were identified and analyzed, and their impacts were quantified. In addition, "what-if" analysis was conducted to identify potential process improvement strategies in the form of recommendations to the hospital leadership. Such a model provides a quantitative tool for continuous improvement and process control in radiology outpatient test scheduling process to reduce financial losses associated with process error. This method of analysis is also applicable to other departments in the hospital.

  10. The impact of radiology expertise upon the localization of subtle pulmonary lesions

    Science.gov (United States)

    Robinson, John W.; Brennan, Patrick C.; Mello-Thoms, Claudia; Lewis, Sarah J.

    2016-03-01

    Rationale and objectives: This study investigates the influence of radiology expertise in the correct localization of lesions when radiologists are requested to complete an observer task. Specifically, the ability to detect pulmonary lesions of different subtleties is explored in relation to radiologists' reported specialty. Materials and Methods: Institutional ethics was granted. Ten radiologists (5 thoracic, 5 non-thoracic) interpreted 40 posterior-anterior (PA) chest x-rays (CXRs) consisting of 21 normal and 19 abnormal cases (solitary pulmonary nodule). The abnormal cases contained a solitary nodule with an established subtlety (subtlety 5 = obvious to subtlety 1 = extremely subtle). Radiologists read the test set and identified any pulmonary nodule using a 1-5 confidence scale (1=no pulmonary nodule to 5=highest confidence case contains a pulmonary lesion). The radiologists interpreted the image bank twice and the cases were randomized for each reader between reads. Results: The Kruskal-Wallis test identified that subtlety of nodules significantly influenced the sensitivity of nonthoracic radiologists (P=test demonstrated a significant difference in sensitivity for radiologist specialisation (P=0.013), with thoracic radiologists better compared to non-thoracic radiologists (mean sensitivity 0.479 and 0.389 respectively). The sensitivity of nodule detection decreased when comparing subtlety 4 to 3, 3 to 2 and 2 to 1 for non-thoracic and thoracic radiologists'with the subtlety 3 to subtlety 2 being significant (P=0.014) for non thoracic radiologists while thoracic radiologists' demonstrated a decrease but no transitions between subtlety were significant. The most noticeable, and interesting, effect was with the thoracic radiologists' with the average means of subtlety 2 and 1 being almost the same and closely comparable to level 3. Conclusion: Results from this study indicate that expertise in chest radiology does significantly impact upon the sensitivity of

  11. Impact of Communication Errors in Radiology on Patient Care, Customer Satisfaction, and Work-Flow Efficiency.

    Science.gov (United States)

    Siewert, Bettina; Brook, Olga R; Hochman, Mary; Eisenberg, Ronald L

    2016-03-01

    The purpose of this study is to analyze the impact of communication errors on patient care, customer satisfaction, and work-flow efficiency and to identify opportunities for quality improvement. We performed a search of our quality assurance database for communication errors submitted from August 1, 2004, through December 31, 2014. Cases were analyzed regarding the step in the imaging process at which the error occurred (i.e., ordering, scheduling, performance of examination, study interpretation, or result communication). The impact on patient care was graded on a 5-point scale from none (0) to catastrophic (4). The severity of impact between errors in result communication and those that occurred at all other steps was compared. Error evaluation was performed independently by two board-certified radiologists. Statistical analysis was performed using the chi-square test and kappa statistics. Three hundred eighty of 422 cases were included in the study. One hundred ninety-nine of the 380 communication errors (52.4%) occurred at steps other than result communication, including ordering (13.9%; n = 53), scheduling (4.7%; n = 18), performance of examination (30.0%; n = 114), and study interpretation (3.7%; n = 14). Result communication was the single most common step, accounting for 47.6% (181/380) of errors. There was no statistically significant difference in impact severity between errors that occurred during result communication and those that occurred at other times (p = 0.29). In 37.9% of cases (144/380), there was an impact on patient care, including 21 minor impacts (5.5%; result communication, n = 13; all other steps, n = 8), 34 moderate impacts (8.9%; result communication, n = 12; all other steps, n = 22), and 89 major impacts (23.4%; result communication, n = 45; all other steps, n = 44). In 62.1% (236/380) of cases, no impact was noted, but 52.6% (200/380) of cases had the potential for an impact. Among 380 communication errors in a radiology department, 37

  12. Radiology and the mobile device: Radiology in motion

    Directory of Open Access Journals (Sweden)

    Sridhar G Panughpath

    2012-01-01

    Full Text Available The use of mobile devices is revolutionizing the way we communicate, interact, are entertained, and organize our lives. With healthcare in general and radiology in particular becoming increasingly digital, the use of such devices in radiologic practice is inevitable. This article reviews the current status of the use of mobile devices in the clinical practice of radiology, namely in emergency teleradiology. Technical parameters such as luminance and resolution are discussed. The article also discusses the benefits of such mobility vis-à-vis the current limitations of the technologies available.

  13. Radiology and the mobile device: Radiology in motion

    International Nuclear Information System (INIS)

    Panughpath, Sridhar G; Kalyanpur, Arjun

    2012-01-01

    The use of mobile devices is revolutionizing the way we communicate, interact, are entertained, and organize our lives. With healthcare in general and radiology in particular becoming increasingly digital, the use of such devices in radiologic practice is inevitable. This article reviews the current status of the use of mobile devices in the clinical practice of radiology, namely in emergency teleradiology. Technical parameters such as luminance and resolution are discussed. The article also discusses the benefits of such mobility vis-à-vis the current limitations of the technologies available

  14. Bacteriological Monitoring of Radiology Room Apparatus in the Department of Radiological Technology and Contamination on Hands of Radiological Technologists

    International Nuclear Information System (INIS)

    Kim, Seon Chil

    2008-01-01

    Distribution of microorganisms were examined for the bucky tables in the radiology rooms of the department of radiological technology, the aprons, handles of various apparatus, handles of mobile radiological apparatus, and hands of the radiological technologists. As a result, relatively larger amounts of bacteria were found on the handles of the mobile radiological apparatus and the aprons. Among the isolated bacteria, Acinetobacter baumanni (7.3%), Klebsiella pneumoniae (6.7%), Staphylococcus aureus (3.9%), Serratia liquefaciens (1.7%), Enterobacter cloaceae (0.6%), Providenica rettgeri (0.6%) are known as the cause of nosocomial infection (hospital acquired infection). In addition, similar colonies were also found on the hands of the radiological technologists such as microorganisms of Klebsiella pneumoniae (8.4%), Staphylococcus aureus (6.6%), Yersinia enterocolotica (5.4%), Acinetobacter baumanni (4.2%), Enterobacter cloaceae (2.4%), Serratia liquefaciens (1.8%), Yersinia pseuotuberculosis (18%), Enterobacter sakazakii (1.2%), and Escherichia coli (0.6%). In particular, this result indicates clinical significance since Staphylococcus aureus and Escherichia coli show strong pathogenicity. Therefore, a continuous education is essential for the radiological technologists to prevent the nosocomial infection.

  15. Bacteriological Monitoring of Radiology Room Apparatus in the Department of Radiological Technology and Contamination on Hands of Radiological Technologists

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Seon Chil [Dept. of Radiologic Technology, Daegu Health College, Daegu (Korea, Republic of)

    2008-12-15

    Distribution of microorganisms were examined for the bucky tables in the radiology rooms of the department of radiological technology, the aprons, handles of various apparatus, handles of mobile radiological apparatus, and hands of the radiological technologists. As a result, relatively larger amounts of bacteria were found on the handles of the mobile radiological apparatus and the aprons. Among the isolated bacteria, Acinetobacter baumanni (7.3%), Klebsiella pneumoniae (6.7%), Staphylococcus aureus (3.9%), Serratia liquefaciens (1.7%), Enterobacter cloaceae (0.6%), Providenica rettgeri (0.6%) are known as the cause of nosocomial infection (hospital acquired infection). In addition, similar colonies were also found on the hands of the radiological technologists such as microorganisms of Klebsiella pneumoniae (8.4%), Staphylococcus aureus (6.6%), Yersinia enterocolotica (5.4%), Acinetobacter baumanni (4.2%), Enterobacter cloaceae (2.4%), Serratia liquefaciens (1.8%), Yersinia pseuotuberculosis (18%), Enterobacter sakazakii (1.2%), and Escherichia coli (0.6%). In particular, this result indicates clinical significance since Staphylococcus aureus and Escherichia coli show strong pathogenicity. Therefore, a continuous education is essential for the radiological technologists to prevent the nosocomial infection.

  16. Quantitative Evaluation of Iranian Radiology Papers and Its Comparison with Selected Countries

    International Nuclear Information System (INIS)

    Ghafoori, Mahyar; Emami, Hasan; Sedaghat, Abdolrasoul; Ghiasi, Mohammad; Shakiba, Madjid; Alavi, Manijeh

    2014-01-01

    Recent technological developments in medicine, including modern radiology have promoted the impact of scientific researches on social life. The scientific outputs such as article and patents are products that show the scientists’ attempt to access these achievements. In the current study, we evaluate the current situation of Iranian scientists in the field of radiology and compare it with the selected countries in terms of scientific papers. For this purpose, we used scientometric tools to quantitatively assess the scientific papers in the field of radiology. Radiology papers were evaluated in the context of medical field audit using retrospective model. We used the related databases of biomedical sciences for extraction of articles related to radiology. In the next step, the situation of radiology scientific products of the country were determined with respect to the under study regional countries. Results of the current study showed a ratio of 0.19% for Iranian papers in PubMed database published in 2009. In addition, in 2009, Iranian papers constituted 0.29% of the Scopus scientific database. The proportion of Iranian papers in the understudy region was 7.6%. To diminish the gap between Iranian scientific radiology papers and other competitor countries in the region and achievement of document 2025 goals, multifold effort of the society of radiology is necessary

  17. Cost-benefit analysis for U.S. NRC proposed radiological criteria for decommissioning

    International Nuclear Information System (INIS)

    Meck, R.A.

    1995-01-01

    The U.S. Nuclear Regulatory Commission prepared cost-benefit analyses in support of the proposed regulation on radiological criteria for decommissioning. These analyses have been published in the Draft Generic Environmental Impact Statement (GEIS), NUREG-1496, and in the Draft Regulatory Analysis (RA). The method used was to first list the reasonable regulatory alternatives that could be considered. Second, for each regulatory alternative, we analyzed and compared the costs and the incremental radiological and non-radiological impacts to workers and members of the public. The regulatory alternatives for unrestricted use of a site that were analyzed and compared were: no regulatory change; a uniform risk based on total effective dose equivalent (TEDE); use of 'best' available technology; and returning the level of radioactivity attributable to licensed activity to background levels. The analyses were performed for ten types of reference facilities, and each facility was evaluated at low, medium, and high levels of contamination. The reference facilities included: reactors; various uranium and non-fuel cycle facilities; and independent spent fuel storage installations. Since both the radiological and non-radiological benefits were considered, the benefits of the various alternatives were measured in terms of 'Estimated Mortalities Averted.' Conclusions supported by the analyses were that a risk limit, expressed as a 15 mrem/y dose, is reasonable both as a level for protecting public health and safety and with regard to its cost-benefit effects. Further reductions on a site-specific application of the ALARA principle are also supported in the context of accounting for both the radiological and non-radiological effects in both the short and long terms. Restricted release is also supported when the same level of protection is provided in decommissioning those facilities that cannot reasonably meet the unrestricted release criteria. (J.P.N.)

  18. Portrayal of radiology in a major medical television series: How does it influence the perception of radiology among patients and radiology professionals?

    International Nuclear Information System (INIS)

    Heye, T.; Merkle, E.M.; Boll, D.T.; Leyendecker, J.R.; Gupta, R.T.

    2016-01-01

    To assess how the portrayal of Radiology on medical TV shows is perceived by patients and radiology professionals. In this IRB-approved study with patient consent waived, surveys were conducted among adult patients scheduled for radiological examinations and radiology professionals. The questionnaire investigated medical TV watching habits including interest in medical TV shows, appearance of radiological examination/staff, radiology's role in diagnosis-making, and rating of the shows' accuracy in portraying radiology relative to reality. One hundred and twenty-six patients and 240 professionals (133 technologists, 107 radiologists) participated. 63.5 % patients and 63.2 % technologists rated interest in medical TV shows ≥5 (scale 1-10) versus 38.3 % of radiologists. All groups noted regular (every 2nd/3rd show) to >1/show appearance of radiological examinations in 58.5-88.2 % compared to 21.0-46.2 % for radiological staff appearance. Radiology played a role in diagnosis-making regularly to >1/show in 45.3-52.6 %. There is a positive correlation for interest in medical TV and the perception that radiology is accurately portrayed for patients (r = 0.49; P = 0.001) and technologists (r = 0.38; P = 0.001) but not for radiologists (r = 0.01). The majority of patients perceive the portrayed content as accurate. Radiologists should be aware of this cultivation effect to understand their patients' behaviour which may create false expectations towards radiological examinations and potential safety hazards. (orig.)

  19. Evaluation guide for the radiological impact study of a basic nuclear installation (BNI) as a support for the authorization application of releases

    International Nuclear Information System (INIS)

    Chartier, Mr.; Despres, A.; Supervil, S.; Conte, D.; Hubert, P.; Oudiz, A.; Champion, D.

    2002-10-01

    At the time of a licence application of effluent releases and water pumping of basic nuclear facilities (BNF), the operator of the installation must in particular provide a radiological impact study of the radioactive effluent releases coming from the installation on the environment and on public health. An impact study of the radioactive releases represents technical and conditional specifications. It was for this reason that the French Safety Authority (ASN then DSIN) and the Directorate-General of Health Services (DGS) requested IRSN (then IPSN), in April 1999, to develop a guide facilitating the review of such a study, as well for the services implied in the examination of the licence applications, as for all the concerned parties in this field. The objective of the guide is to take into account the regulatory context which underlies the development of the impact studies (decree no. 95-540 of May 4, 1995, modified by the decree no. 2002-460 of April 4, 2002, and the Euratom guideline 96/29 of May 13, 1996, known as 'the basic standard guideline', accompanied by its transposition texts in French law). In this precise context, the guide proposes to assess the radiological impact study of a BNF from three different angles: - the description and the quantification of the produced effluents, by taking account of the triggering processes, of the different processing measures and of the procedures to optimise the reduction of the produced effluents; - the estimate of the dosimetric impact of the planned releases on the population, taking into account the environmental characteristics of the installation; - the definition of the conditions to monitor the releases and the environment. This guide provides a general condition logical framework adaptable to any particular situation met

  20. ICRP recommendations on 'managing patient dose in digital radiology'

    International Nuclear Information System (INIS)

    Vano, E.

    2005-01-01

    The International Commission on Radiological Protection (ICRP) approved the publication of a document on 'Managing patient dose in digital radiology' in 2003. The paper describes the content of the report and some of its key points, together with the formal recommendations of the Commission on this topic. With digital techniques exists not only the potential to improve the practice of radiology but also the risk to overuse radiation. The main advantages of digital imaging: wide dynamic range, post-processing, multiple viewing options, electronic transfer and archiving possibilities are clear but overexposures can occur without an adverse impact on image quality. It is expected that the ICRP report helps to profit from the benefits of this important technological advance in medical imaging with the best management of radiation doses to the patients. It is also expected to promote training actions before the digital techniques are introduced in the radiology departments and to foster the industry to offer enough technical and dosimetric information to radiologists, radiographers and medical physicists to help in the optimisation of the imaging. (authors)

  1. Collaborative filtering to improve navigation of large radiology knowledge resources.

    Science.gov (United States)

    Kahn, Charles E

    2005-06-01

    Collaborative filtering is a knowledge-discovery technique that can help guide readers to items of potential interest based on the experience of prior users. This study sought to determine the impact of collaborative filtering on navigation of a large, Web-based radiology knowledge resource. Collaborative filtering was applied to a collection of 1,168 radiology hypertext documents available via the Internet. An item-based collaborative filtering algorithm identified each document's six most closely related documents based on 248,304 page views in an 18-day period. Documents were amended to include links to their related documents, and use was analyzed over the next 5 days. The mean number of documents viewed per visit increased from 1.57 to 1.74 (P Collaborative filtering can increase a radiology information resource's utilization and can improve its usefulness and ease of navigation. The technique holds promise for improving navigation of large Internet-based radiology knowledge resources.

  2. Radiological characterization of a uranium mine with no mining activity

    International Nuclear Information System (INIS)

    Lozano, J.C.; Vera Tome, F.; Gomez Escobar, V.; Blanco Rodriguez, P.

    2000-01-01

    We report a radiological study of a uranium mine located in Extremadura, in the south-west of Spain, in which mining work had ceased. One interest in the work is that the results can be used as a reference for the future evaluation of the effects produced by the restoration program. The radiological parameters selected to estimate the impact of the inactive mine were: 222 Rn in air and water, 222 Rn exhalation, effective 226 Ra in soils and sediments, and natural uranium and 226 Ra in water. Chemical analyses of water samples and measurements of meteorological variables were also made. Average values of these radiological parameters are presented. We characterize the zone radiologically and estimate the influence of the mine on the basis of some of these parameters, while others are used to reflect the status of the installation, information which could be very useful in the near future when restoration is complete

  3. Computer-aided diagnosis in chest radiology.

    Science.gov (United States)

    MacMahon, H; Doi, K; Chan, H P; Giger, M L; Katsuragawa, S; Nakamori, N

    1990-01-01

    Digital radiography offers several important advantages over conventional systems, including abilities for image manipulation, transmission, and storage. In the long term, however, the unique ability to apply artificial intelligence techniques for automated detection and quantitation of disease may have an even greater impact on radiologic practice. Although CAD is still in its infancy, the results of several recent studies clearly indicate a major potential for the future. The concept of using computers to analyze medical images is not new, but recent advances in computer technology together with progress in implementing practical digital radiography systems have stimulated research efforts in this exciting field. Several facets of CAD are presently being developed at the University of Chicago and elsewhere for application in chest radiology as well as in mammography and vascular imaging. To date, investigators have focused on a limited number of subjects that have been, by their nature, particularly suitable for computer analysis. There is no aspect of radiologic diagnosis that could not potentially benefit from this approach, however. The ultimate goal of these endeavors is to provide a system for comprehensive automated image analysis, the results of which could be accepted or modified at the discretion of the radiologist.

  4. Current radiology. Volume 5

    International Nuclear Information System (INIS)

    Wilson, G.H.; Hanafee, W.N.

    1984-01-01

    This book contains 10 selections. They are: Nuclear Magnetic Resonance Imaging, Interventional Vascular Radiology, Genitourinary Radiology, Skeletal Radiology, Digital Subtraction Angiography, Neuroradiology, Computed Tomographic Evaluation of Degenerative Diseases of the Lumbar Spine, The Lung, Otolaringology and Opthalmology, and Pediatric Radiology: Cranial, Facial, Cervical, Vertebral, and Appendicular

  5. Interaction techniques for radiology workstations: impact on users' productivity

    Science.gov (United States)

    Moise, Adrian; Atkins, M. Stella

    2004-04-01

    As radiologists progress from reading images presented on film to modern computer systems with images presented on high-resolution displays, many new problems arise. Although the digital medium has many advantages, the radiologist"s job becomes cluttered with many new tasks related to image manipulation. This paper presents our solution for supporting radiologists" interpretation of digital images by automating image presentation during sequential interpretation steps. Our method supports scenario based interpretation, which group data temporally, according to the mental paradigm of the physician. We extended current hanging protocols with support for "stages". A stage reflects the presentation of digital information required to complete a single step within a complex task. We demonstrated the benefits of staging in a user study with 20 lay subjects involved in a visual conjunctive search for targets, similar to a radiology task of identifying anatomical abnormalities. We designed a task and a set of stimuli which allowed us to simulate the interpretation workflow from a typical radiology scenario - reading a chest computed radiography exam when a prior study is also available. The simulation was possible by abstracting the radiologist"s task and the basic workstation navigation functionality. We introduced "Stages," an interaction technique attuned to the radiologist"s interpretation task. Compared to the traditional user interface, Stages generated a 14% reduction in the average interpretation.

  6. Medical Ethics in Radiology

    International Nuclear Information System (INIS)

    Kim, Kyung Won; Park, Jae Hyung; Yoon, Soon Ho

    2010-01-01

    According to the recent developments in radiological techniques, the role of radiology in the clinical management of patients is ever increasing and in turn, so is the importance of radiology in patient management. Thus far, there have been few open discussions about medical ethics related to radiology in Korea. Hence, concern about medical ethics as an essential field of radiology should be part of an improved resident training program and patient management. The categories of medical ethics related with radiology are ethics in the radiological management of patient, the relationship of radiologists with other medical professionals or companies, the hazard level of radiation for patients and radiologists, quality assurance of image products and modalities, research ethics, and other ethics issues related to teleradiology and fusion imaging. In order to achieve the goal of respectful progress in radiology as well as minimizing any adverse reaction from other medical professions or society, we should establish a strong basis of medical ethics through the continuous concern and self education

  7. Radiological Impact Study of the Coal-Fired Power Plant of Narcea

    Energy Technology Data Exchange (ETDEWEB)

    Robles, B.; Baeza, A.; Mora, J. a.; Corbacho, J. a.; Trueba, C.; Guillen, J.; Rodriguez, Miralles, Y.

    2014-04-01

    Coal, fuel used in thermal power plants for electricity production, contains variable concentrations of naturally occurring radionuclides from natural disintegration series of {sup 2}38U, {sup 2}35U, {sup 2}32Th and also the 40K, which are enhanced in the wastes and coproducts due to the industrial process. For this reason, natural radionuclides which are part of the noncombustible fraction of coal, except those volatiles which incorporate directly to the flue gases, concentrates and are partitioned between fly ashes and bottom ashes. This enhancement could cause, to the workers of the installation and to members of the public around the plant, an increase in the exposure which should be assessed under the radiation protection point of view. Present report collect the results obtained from a screening assessment of the radiological impact derived from the normal operation of the Narcea coal-fired power plant. The project where this assessment was performed is part of a bigger project which is jointly developed by the Unit of Radiation Protection of the Public and the Environment (UPRPYMA) of CIEMAT and the Environmental Radioactivity Laboratory of the Extremadura University (LARUEX) in agreement with the Spanish Association of the Electrical Industry (ENUSA). (Author)

  8. Analysis of papers in radiological journals in recent years: a comparison of journal of Korean radiologic society and radiology

    International Nuclear Information System (INIS)

    Kim, Jin Suh; Kim, Jae Kyun; Han, Dong Bok; Lim, Tae Hwan

    1997-01-01

    The purpose of this study was to determine current trends and the mode of future development in the field of medical radiology and to promote research among the nation's radiologists by analyzing the contents of the Journal of the Korean Radiologic Society(JKRS) and Radiology. The number of articles published in JKRS each year between 1990 and 1994 was counted. The research articles in JKRS(n=740) and in Radiology(n=1748) between 1992 and 1994 were categorized according to the objective, type, topic, materials, and radiologic techniques of their contents on the basis of predetermined criteria. Domestic Masters theses(n=126) and doctoral dissertations(n=75) accepted between 1990 and 1994, and domestic materials published in international journals (n=416) between 1986 and 1994 were also categorized using the same criteria. The greatest increase in the number of articles published in JKRS was seen during 1994. The majority of these aimed to retrospectively analyse the findings of diseases while the majority of articles published in Radiology dealt prospectively with the development and/or evaluation of diagnostic methods. More variety of topics and issues was seen in Radiology than in JKRS. The number of articles of domestic materials published in international journals increased from 1986 to 1994, while the number of articles of foreign materials published in Korea was relatively stationary : A significant number of theses and dissertations dealt, mostly prospectively, with studies of pathophysiologic and/or pharmacologic mechanisms using animal models. In order to understand both current trends and the direction and mode of future developments in the field of radiology, and to be able to actively deal with challenges at the forefront of radiologic development, it is essential to review research articles published in radiology-related journals

  9. Modelling of the radiological impact of radioactive waste dumping in the Arctic Seas. Report of the Modelling and Assessment Working Group of the International Arctic Seas Assessment Project (IASAP)

    International Nuclear Information System (INIS)

    2003-01-01

    The work is summarized carried out by the Modelling and Assessment Working Group in 1994-1996. The Modelling and Assessment Working Group was established within the framework of the International Arctic Seas Assessment Project (IASAP) launched by the IAEA in 1993 with the objectives of modelling the environmental dispersal and transport of nuclides to be potentially released from the dumped objects and of assessing the associated radiological impact on man and biota. Models were developed to model the dispersal of the pollutants and for the assessment of the radiological consequences of the releases from the dumped wastes in the Arctic. The results of the model intercomparison exercise were used as a basis on which to evaluate the estimate of concentration fields when detailed source term scenarios were used and also to assess the uncertainties in ensuing dose calculations. The descriptions and modelling work was divided into three main phases: description of the area, collection of relevant and necessary information; extension to and development of predictive models including an extensive model inter-comparison and finally prediction of radiological impact, used in the evaluation of the need and options for remediation

  10. Medical student knowledge regarding radiology before and after a radiological anatomy module: implications for vertical integration and self-directed learning.

    Science.gov (United States)

    Murphy, Kevin P; Crush, Lee; O'Malley, Eoin; Daly, Fergus E; O'Tuathaigh, Colm M P; O'Connor, Owen J; Cryan, John F; Maher, Michael M

    2014-10-01

    To examine the impact that anatomy-focused radiology teaching has on non-examined knowledge regarding radiation safety and radiology as a specialty. First-year undergraduate medical students completed surveys prior to and after undertaking the first-year anatomy programme that incorporates radiological anatomy. Students were asked opinions on preferred learning methodology and tested on understanding of radiology as a specialty and radiation safety. Pre-module and post-module response rates were 93 % (157/168) and 85 % (136/160), respectively. Pre-module and post-module, self-directed learning (SDL) ranked eighth (of 11) for preferred gross-anatomy teaching formats. Correct responses regarding radiologist/radiographer roles varied from 28-94 % on 16 questions with 4/16 significantly improving post-module. Identification of modalities that utilise radiation significantly improved for five of eight modalities post-module but knowledge regarding relative amount of modality-specific radiation use was variable pre-module and post-module. SDL is not favoured as an anatomy teaching method. Exposure of students to a radiological anatomy module delivered by senior clinical radiologists improved basic knowledge regarding ionising radiation use, but there was no improvement in knowledge regarding radiation exposure relative per modality. A possible explanation is that students recall knowledge imparted in didactic lectures but do little reading around the subject when the content is not examined. • Self-directed learning is not favoured as a gross anatomy teaching format amongst medical students. • An imaging anatomy-focused module improved basic knowledge regarding ionising radiation use. • Detailed knowledge of modality-specific radiation exposure remained suboptimal post-module. • Knowledge of roles within a clinical radiology department showed little change post-module.

  11. Bioremediation: Effectiveness in reducing the ecological impact

    International Nuclear Information System (INIS)

    Scholten, M.C.T.

    1992-01-01

    Bioremediation becomes an important technique in oil spill combat programmes. The purpose is to shorten the exposure time of biota to oil compounds, in order to reduce long term environmental effects. Although bioremediation products have the advantage of stimulating the natural capacity to degrade oil, there are some limitations to be considered. Application as a technique for first emergency actions following an oil spill is not effective, and can therefore be no alternative for dispersion or mechanical removal of floating or freshly stranded oil slicks. Acute toxic effects are related to the short term exposure to unweathered oils. An immediate removal of oil is necessary to reduce the extent of the environmental impact of an oil spill. Physical processes (transport, dilution and evaporation) are determining the initial fate of environmentally released oil. Biodegradation only becomes important as a process of removing oil in the next phase. It is the only effective way to further reduce the concentration of oil that is left in (intertidal) coastal areas. Bioremediation thus reduces the duration of the environmental impact of an oil spill. This is especially important in ecosystems with a low recovery potential (e.g., salt marshes, rocky shores). The experimental evaluation of bioremediation products is mainly based on the capacity to reduce fresh oil and the acute toxicity of the product itself, rather than on the capacity to enhance the further reduction of weathered oil and the toxicological consequences of higher release rates of intermediate metabolites produced during the biotransformation processes

  12. Machine Learning and Radiology

    Science.gov (United States)

    Wang, Shijun; Summers, Ronald M.

    2012-01-01

    In this paper, we give a short introduction to machine learning and survey its applications in radiology. We focused on six categories of applications in radiology: medical image segmentation, registration, computer aided detection and diagnosis, brain function or activity analysis and neurological disease diagnosis from fMR images, content-based image retrieval systems for CT or MRI images, and text analysis of radiology reports using natural language processing (NLP) and natural language understanding (NLU). This survey shows that machine learning plays a key role in many radiology applications. Machine learning identifies complex patterns automatically and helps radiologists make intelligent decisions on radiology data such as conventional radiographs, CT, MRI, and PET images and radiology reports. In many applications, the performance of machine learning-based automatic detection and diagnosis systems has shown to be comparable to that of a well-trained and experienced radiologist. Technology development in machine learning and radiology will benefit from each other in the long run. Key contributions and common characteristics of machine learning techniques in radiology are discussed. We also discuss the problem of translating machine learning applications to the radiology clinical setting, including advantages and potential barriers. PMID:22465077

  13. Reducing food's environmental impacts through producers and consumers.

    Science.gov (United States)

    Poore, J; Nemecek, T

    2018-06-01

    Food's environmental impacts are created by millions of diverse producers. To identify solutions that are effective under this heterogeneity, we consolidated data covering five environmental indicators; 38,700 farms; and 1600 processors, packaging types, and retailers. Impact can vary 50-fold among producers of the same product, creating substantial mitigation opportunities. However, mitigation is complicated by trade-offs, multiple ways for producers to achieve low impacts, and interactions throughout the supply chain. Producers have limits on how far they can reduce impacts. Most strikingly, impacts of the lowest-impact animal products typically exceed those of vegetable substitutes, providing new evidence for the importance of dietary change. Cumulatively, our findings support an approach where producers monitor their own impacts, flexibly meet environmental targets by choosing from multiple practices, and communicate their impacts to consumers. Copyright © 2018 The Authors, some rights reserved; exclusive licensee American Association for the Advancement of Science. No claim to original U.S. Government Works.

  14. Automated Calibration of Dosimeters for Diagnostic Radiology

    International Nuclear Information System (INIS)

    Romero Acosta, A.; Gutierrez Lores, S.

    2015-01-01

    Calibration of dosimeters for diagnostic radiology includes current and charge measurements, which are often repetitive. However, these measurements are usually done using modern electrometers, which are equipped with an RS-232 interface that enables instrument control from a computer. This paper presents an automated system aimed to the measurements for the calibration of dosimeters used in diagnostic radiology. A software application was developed, in order to achieve the acquisition of the electric charge readings, measured values of the monitor chamber, calculation of the calibration coefficient and issue of a calibration certificate. A primary data record file is filled and stored in the computer hard disk. The calibration method used was calibration by substitution. With this system, a better control over the calibration process is achieved and the need for human intervention is reduced. the automated system will be used in the calibration of dosimeters for diagnostic radiology at the Cuban Secondary Standard Dosimetry Laboratory of the Center for Radiation Protection and Hygiene. (Author)

  15. Advantages of digital imaging for radiological diagnostic

    International Nuclear Information System (INIS)

    Trapero, M. A.; Gonzalez, S.; Albillos, J. C.; Martel, J.; Rebollo, M.

    2006-01-01

    The advantages and limitations of radiological digital images in comparison with analogic ones are analyzed. We discuss three main topics: acquisition, post-procedure manipulation, and visualization, archive and communication. Digital acquisition with computed radiology systems present a global sensitivity very close to conventional film for diagnostic purposes. However, flat panel digital systems seems to achieve some advantages in particular clinical situations. A critical issue is the radiation dose-reduction that can be accomplished without reducing image quality nor diagnostic exactitude. The post-procedure manipulation allows, particularly in multiplanar modalities like CT or MR, to extract all implicit diagnostic information in the images: Main procedures are multiplanar and three-dimensional reformations, dynamic acquisitions, functional studies and image fusion. The use of PACS for visualization, archive and communication of images, improves the effectiveness and the efficiency of the workflow, allows a more comfortable diagnosis for the radiologist and gives way to improvements in the communication of images, allowing tele consulting and the tele radiology. (Author) 6 refs

  16. Contrast media properties in interventional radiology

    International Nuclear Information System (INIS)

    Laerum, F.; Enge, I.

    1989-01-01

    Potential hazards of the use of contrast media (CM) in interventional radiology are analyzed by looking into each procedure regarding interactions of CM with pharmaceutical additives, with technical equipment possibly affecting CM stability, and special local or systemic demands related to the procedure. Also the impact of these factors upon the physiological mechanisms are taken into account. (H.W.). 32 refs.; 4 figs.; 2 tabs

  17. Methodology to assess the radiological sensitivity of soils: Application to Spanish soils

    International Nuclear Information System (INIS)

    Trueba Alonso, C.

    2005-01-01

    A methodology, based on standard physical and chemical soil properties, has been developed to estimate the radiological sensitivity of soils to a 137 C s and 90 S r contamination. In this framework, the soil radiological sensitivity is defined as the soil capability to mobilise or to retain these radionuclides. The purpose of this methodology is to assess, in terms of radiological sensitivity indexes, the behaviour of 137 C s and 90 S r in soils and their fluxes to man, considering two exposure pathways, the external irradiation exposure and the internal exposure from ingestion. The methodology is applied to the great variety of soil types found in Spain, where the soil profile is the reference unit for the assessment. The results for these soil types show, that their basic soil properties are the key to categorise the radiological sensitivity according to the risks considered. The final categorisation allows to identify soils specially sensible and improves the radiological impact assessment predictions. (Author)

  18. Varied clinico-radiological presentations of transmigrated canines

    Directory of Open Access Journals (Sweden)

    Ishita Gupta

    2015-01-01

    Full Text Available Canine is one of the most commonly impacted teeth in the dental arch. An unerupted permanent canine crossing the midline is called transmigration and is an unusual event. We report nine cases of impacted canine transmigration. Maxillary canine transmigration, bilateral transmigration, and transmigration associated with odontoma are rare presentations. This article discusses the varied clinico-radiologic presentations, etiology, and treatment options of transmigration. It also emphasizes the importance of panoramic radiographs for evaluation of over-retained deciduous canines or missing permanent canines.

  19. Radiological protection and quality control for diagnostic radiology in China

    International Nuclear Information System (INIS)

    Baorong, Yue

    2008-01-01

    Full text: There are 43,000 diagnostic departments, nearly 70,000 X-ray diagnostic facilities, 7,000 CT, 250 million for the annual total numbers of X-ray examinations, 120,000 occupationally exposed workers in diagnostic radiology. 'Basic standards for protection against ionizing radiation and for the safety of radiation sources' is promulgated on October, 2002. This basic standard follows the BSS. 'Rule on the administration of radio-diagnosis and radiotherapy', as a order of the Ministry of Health No. 46, is promulgated by Minister of Health on January 24, 2006. It includes general provisions, requirements and practice, establishment and approval of radio-diagnosis and radiotherapy services, safeguards and quality assurance, and so on. There are a series of radiological protection standards and quality control standards in diagnostic radiology, including 'radiological protection standard for the examination in X-ray diagnosis', 'radiological health protection standards for X-ray examination of child-bearing age women and pregnant women', 'radiological protection standards for the children in X-ray diagnosis', 'standards for radiological protection in medical X-ray diagnosis', 'specification for radiological protection monitoring in medical X-ray diagnosis', 'guide for reasonable application of medical X-ray diagnosis', 'general aspects for quality assurance in medical X-ray image of diagnosis', 'specification of image quality control test for the medical X-ray diagnostic equipment', 'specification of image quality assurance test for X-ray equipment for computed tomography', 'specification for testing of quality control in computed radiography (CR)' and 'specification for testing of quality control in X-ray mammography'. With the X-ray diagnostic equipment, there are acceptant tests, status tests and routing tests in large hospitals. It is poor for routing test in middle and smaller hospitals. CT is used widely in diagnostic radiology, however most workers in CT

  20. 2000 RSNA annual oration in diagnostic radiology: The future of interventional radiology.

    Science.gov (United States)

    Becker, G J

    2001-08-01

    Origins in imaging, procedural emphasis, and dependence on innovation characterize interventional radiology, which will continue as the field of image-guided minimally invasive therapies. A steady supply of innovators will be needed. Current workforce shortages demand that this problem be addressed and in an ongoing fashion. Interventional radiology's major identity problem will require multiple corrective measures, including a name change. Diagnostic radiologists must fully embrace the concept of the dedicated interventionalist. Interspecialty turf battles will continue, especially with cardiologists and vascular surgeons. To advance the discipline, interventional radiologists must remain involved in cutting-edge therapies such as endograft repair of aortic aneurysms and carotid stent placement. As the population ages, interventionalists will experience a shift toward a greater emphasis on cancer treatment. Political agendas and public pressure will improve access to care and result in managed health care reforms. Academic centers will continue to witness a decline in time and resources available to pursue academic missions. The public outcry for accountability will result in systems changes aimed at reducing errors and process changes in the way physicians are trained, certified, and monitored. Evidence-based medicine will be the watchword of this century. Interventional radiology will maintain its role through development of methods for delivery of genes, gene products, and drugs to specific target sites; control of angiogenesis and other biologic processes; and noninvasive image-guided delivery of various forms of energy for ablation.

  1. Research in diagnostic radiology: a holistic perspective

    International Nuclear Information System (INIS)

    Abrams, H.L.

    1981-01-01

    This 24th Annual Crookshank Lecture of the Royal College of Radiologists reviews the continuity and interactive relationships among the various components of radiological research, with particular reference to imaging. The following aspects are considered: 1) Clinical decision-making indications vs. yield and cost vs. utility in relation to diagnostic processes. 2) Generation of the image, including x-ray tubes, cinefluorography, ultrasound, CT, N.M.R.; biological radiation effects. 3) Enhancement of the image, optimised information yield. 4) Image perception 5) Boundaries of the radiological process, e.g. radioimmunoassay, isotopes in tumour therapy, venous sampling for assay 6) Image interpretation, its pathophysiological roots and resultant disease research 7) Impact of the image, and the effect of the decision process of therapeutic alternatives. (U.K.)

  2. Analysis of radioactive contaminations and radiological hazard in Poland after the Chernobyl reactor accident

    International Nuclear Information System (INIS)

    Zarnowiecki, K.

    1988-01-01

    It is a report on radiological impact in Poland following the Chernobyl reactor accident prepared in the Central Laboratory for Radiological Protection. The results of measurement and its analysis are presented. Isotopic composition of the contamined air and the concentration of radionuclides are determined. The trajectories of the airborne radioactive material movement from Chernobyl to Poland at the last days of April 1986 are presented. Assessment of the radiological risk of the population is done. 38 refs., 20 figs., 11 tabs. (M.F.W.)

  3. CUEX methodology for assessing radiological impacts in the context of ICRP Recommendations

    International Nuclear Information System (INIS)

    Rohwer, P.S.; Kaye, S.V.; Struxness, E.G.

    1975-01-01

    The Cumulative Exposure Index (CUEX) methodology was developed to estimate and assess, in the context of International Commission on Radiological Protection (ICRP) Recommendations, the total radiation dose to man due to environmental releases of radioactivity from nuclear applications. Each CUEX, a time-integrated radionuclide concentration (e.g.μCi.h.cm -3 ), reflects the selected annual dose limit for the reference organ and the estimated total dose to that organ via all exposure modes for a specific exposure situation. To assess the radiological significance of an environmental release of radioactivity, calculated or measured radionuclide concentrations in a suitable environmental sampling medium are compared with CUEXs determined for that medium under comparable conditions. The models and computer codes used in the CUEX methodology to predict environmental transport and to estimate radiation dose have been thoroughly tested. These models and codes are identified and described briefly. Calculation of a CUEX is shown step by step. An application of the methodology to a hypothetical atmospheric release involving four radionuclides illustrates use of the CUEX computer code to assess the radiological significance of a release, and to determine the relative importance (i.e. percentage of the estimated total dose contributed) of each radionuclide and each mode of exposure. The data requirements of the system are shown to be extensive, but not excessive in view of the assessments and analyses provided by the CUEX code. (author)

  4. Methodology for and uses of a radiological source term assessment for potential impacts to stormwater and groundwater

    International Nuclear Information System (INIS)

    Teare, A.; Hansen, K.; DeWilde, J.; Yu, L.; Killey, D.

    2001-01-01

    A Radiological Source Term Assessment (RSTA) was conducted by Ontario Power Generation Inc. (OPG) at the Pickering Nuclear Generating Station (PNGS). Tritium had been identified in the groundwater at several locations under the station, and OPG initiated the RSTA as part of its ongoing efforts to improve operations and to identify potential sources of radionuclide impact to groundwater and stormwater at the station. The RSTA provides a systematic approach to collecting information and assessing environmental risk for radioactive contaminants based on a ranking system developed for the purpose. This paper provides an overview of the RSTA focusing on the investigative approach and how it was applied. This approach can find application at other generating stations. (author)

  5. Radiological safety assessment of transporting radioactive waste to the Gyeongju disposal facility in Korea

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Jong Tae; Baik, Min Hoon; Kang, Mun Ja; Ahn, Hong Joo; Hwang, Doo Seong; Hong, Dae Seok; Jeong, Yong Hwan; Kim, Kyung Su [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2016-12-15

    A radiological safety assessment study was performed for the transportation of low level radioactive wastes which are temporarily stored in Korea Atomic Energy Research Institute (KAERI), Daejeon, Korea. We considered two kinds of wastes: (1) operation wastes generated from the routine operation of facilities; and (2) decommissioning wastes generated from the decommissioning of a research reactor in KAERI. The important part of the radiological safety assessment is related to the exposure dose assessment for the incident-free (normal) transportation of wastes, i.e., the radiation exposure of transport personnel, radiation workers for loading and unloading of radioactive waste drums, and the general public. The effective doses were estimated based on the detailed information on the transportation plan and on the radiological characteristics of waste packages. We also estimated radiological risks and the effective doses for the general public resulting from accidents such as an impact and a fire caused by the impact during the transportation. According to the results, the effective doses for transport personnel, radiation workers, and the general public are far below the regulatory limits. Therefore, we can secure safety from the viewpoint of radiological safety for all situations during the transportation of radioactive wastes which have been stored temporarily in KAERI.

  6. Radiological Safety Assessment of Transporting Radioactive Wastes to the Gyeongju Disposal Facility in Korea

    Directory of Open Access Journals (Sweden)

    Jongtae Jeong

    2016-12-01

    Full Text Available A radiological safety assessment study was performed for the transportation of low level radioactive wastes which are temporarily stored in Korea Atomic Energy Research Institute (KAERI, Daejeon, Korea. We considered two kinds of wastes: (1 operation wastes generated from the routine operation of facilities; and (2 decommissioning wastes generated from the decommissioning of a research reactor in KAERI. The important part of the radiological safety assessment is related to the exposure dose assessment for the incident-free (normal transportation of wastes, i.e., the radiation exposure of transport personnel, radiation workers for loading and unloading of radioactive waste drums, and the general public. The effective doses were estimated based on the detailed information on the transportation plan and on the radiological characteristics of waste packages. We also estimated radiological risks and the effective doses for the general public resulting from accidents such as an impact and a fire caused by the impact during the transportation. According to the results, the effective doses for transport personnel, radiation workers, and the general public are far below the regulatory limits. Therefore, we can secure safety from the viewpoint of radiological safety for all situations during the transportation of radioactive wastes which have been stored temporarily in KAERI.

  7. Augmenting the impact of technology adoption with financial incentive to improve radiology report signature times.

    Science.gov (United States)

    Andriole, Katherine P; Prevedello, Luciano M; Dufault, Allen; Pezeshk, Parham; Bransfield, Robert; Hanson, Richard; Doubilet, Peter M; Seltzer, Steven E; Khorasani, Ramin

    2010-03-01

    Radiology report signature time (ST) can be a substantial component of total report turnaround time. Poor turnaround time resulting from lengthy ST can adversely affect patient care. The combination of technology adoption with financial incentive was evaluated to determine if ST improvement can be augmented and sustained. This prospective study was performed at a 751-bed, urban, tertiary care adult teaching hospital. Test-site imaging volume approximated 48,000 examinations per month. The radiology department has 100 trainees and 124 attending radiologists serving multiple institutions. Over a study period of 4 years and 4 months, three interventions focused on radiologist signature performance were implemented: 1) a notification paging application that alerted radiologists when reports were ready for signature, 2) a picture archiving and communications systems (PACS)-integrated speech recognition report generation system, and 3) a departmental financial incentive to reward radiologists semiannually for ST performance. Signature time was compared before and after the interventions. Wilcoxon and linear regression statistical analyses were used to assess the significance of trends. Technology adoption (paging plus speech recognition) reduced median ST from >5 to 24 to 15 to 18 hours (P financial incentive further improved 80th-percentile ST to 4 to 8 hours (P Technology interventions coupled with financial incentive can result in synergistic and sustainable improvement in radiologist report-signing behavior. The addition of a financial incentive leads to better performance than that achievable through technology alone.

  8. Machine learning and radiology.

    Science.gov (United States)

    Wang, Shijun; Summers, Ronald M

    2012-07-01

    In this paper, we give a short introduction to machine learning and survey its applications in radiology. We focused on six categories of applications in radiology: medical image segmentation, registration, computer aided detection and diagnosis, brain function or activity analysis and neurological disease diagnosis from fMR images, content-based image retrieval systems for CT or MRI images, and text analysis of radiology reports using natural language processing (NLP) and natural language understanding (NLU). This survey shows that machine learning plays a key role in many radiology applications. Machine learning identifies complex patterns automatically and helps radiologists make intelligent decisions on radiology data such as conventional radiographs, CT, MRI, and PET images and radiology reports. In many applications, the performance of machine learning-based automatic detection and diagnosis systems has shown to be comparable to that of a well-trained and experienced radiologist. Technology development in machine learning and radiology will benefit from each other in the long run. Key contributions and common characteristics of machine learning techniques in radiology are discussed. We also discuss the problem of translating machine learning applications to the radiology clinical setting, including advantages and potential barriers. Copyright © 2012. Published by Elsevier B.V.

  9. Radiology in Medical Education: A Pediatric Radiology Elective as a Template for Other Radiology Courses.

    Science.gov (United States)

    Hilmes, Melissa A; Hyatt, Eddie; Penrod, Cody H; Fleming, Amy E; Singh, Sudha P

    2016-03-01

    Traditionally, the pediatric radiology elective for medical students and pediatric residents constituted a morning teaching session focused mainly on radiography and fluoroscopy. A more structured elective was desired to broaden the exposure to more imaging modalities, create a more uniform educational experience, and include assessment tools. In 2012, an introductory e-mail and formal syllabus, including required reading assignments, were sent to participants before the start date. A rotating weekly schedule was expanded to include cross-sectional imaging (ultrasound, CT, MR) and nuclear medicine. The schedule could accommodate specific goals of the pediatric resident or medical student, as requested. Starting in 2013, an online pre-test and post-test were developed, as well as an online end-of-rotation survey specific to the pediatric radiology elective. Taking the Image Gently pledge was required. A scavenger hunt tool, cue cards, and electronic modules were added. Pre-test and post-test scores, averaged over 2 years, showed improvement in radiology knowledge, with scores increasing by 27% for medical students and 21% for pediatric residents. Surveys at the end of the elective were overwhelmingly positive, with constructive criticism and complimentary comments. We have successfully created an elective experience in radiology that dedicates time to education while preserving the workflow of radiologists. We have developed tools to provide a customized experience with many self-directed learning opportunities. Our tools and techniques are easily translatable to a general or adult radiology elective. Copyright © 2016 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  10. Instructional Vignettes in Publication and Journalism Ethics in Radiology Research: Assessment via a Survey of Radiology Trainees.

    Science.gov (United States)

    Rosenkrantz, Andrew B; Ginocchio, Luke A

    2016-07-01

    The aim of the present study was to assess the potential usefulness of written instructional vignettes relating to publication and journalism ethics in radiology via a survey of radiology trainees. A literature review was conducted to guide the development of vignettes, each describing a scenario relating to an ethical issue in research and publication, with subsequent commentary on the underlying ethical issue and potential approaches to its handling. Radiology trainees at a single institution were surveyed regarding the vignettes' perceived usefulness. A total of 21 vignettes were prepared, addressing institutional review board and human subjects protection, authorship issues, usage of previous work, manuscript review, and other miscellaneous topics. Of the solicited trainees, 24.7% (16/65) completed the survey. On average among the vignettes, 94.0% of the participants found the vignette helpful; 19.9 received prior formal instruction on the issue during medical training; 40.0% received prior informal guidance from a research mentor; and 42.0% indicated that the issue had arisen in their own or a peer's prior research experience. The most common previously experienced specific issue was authorship order (93.8%). Free-text responses were largely favorable regarding the value of the vignettes, although also indicated numerous challenges in properly handling the ethical issues: impact of hierarchy, pressure to publish, internal politics, reluctance to conduct sensitive conversations with colleagues, and variability in journal and professional society policies. Radiology trainees overall found the vignettes helpful, addressing commonly encountered topics for which formal and informal guidance were otherwise lacking. The vignettes are publicly available through the Association of University Radiologists (AUR) website and may foster greater insights by investigators into ethical aspects of the publication and journalism process, thus contributing to higher quality

  11. Assessing the initial adaptability and impact of a mobile dictation and reporting system in the radiology department of an academic hospital

    Science.gov (United States)

    Gali, Raja L.; Dave, Jaydev K.

    2017-03-01

    Mobile Radiologist 360, rolled out as part of the voice dictation system upgrade from Nuance Powerscribe 5.0 to PS360 allows an attending radiologist to edit and sign-off a report assigned by a trainee or that has been started by the radiologist on a workstation. The purpose of this study was to evaluate the adoptability and impact of this application. Report turnaround time data was extracted from the RIS (GE-Centricity RIS-IC) for 60 days before- (period-1) and 60 days after- (period-2) the application implementation and then, for 60 days after end of period-2 (period-3). Adoptability of the application was evaluated using two metrics; first, the number of attending radiologists who signed-off reports using the application in periods 2 and 3, and second, the proportion of reports signed-off by the top five users of the mobile application using the application. Impact of the application was evaluated by comparing the time from initial dictation to final sign-off (time_PF) for the top five users of the mobile application to the time_PF by other five radiologists who did not use the application. 41% radiologists used the mobile application at least once during the study period; the proportion of cases signed-off using the mobile application ranged from 1% to 20%. ANOVA revealed no statistically significant effect of the mobile application system on time_PF (p=0.842). In conclusion, there was low initial adoptability and no impact of the mobile dictation and reporting system in reducing the time from initial dictation to final sign-off on a radiology report.

  12. In the Lead Again Horizontal-Ellipsis [Journal of Cardiovascular and Interventional Radiology

    Energy Technology Data Exchange (ETDEWEB)

    Vorwerk, Dierk, E-mail: dierk.vorwerk@klinikum-ingolstadt.de [Ingolstadt Hospital, Department of Diagnostic and Interventional Radiology (Germany)

    2013-10-15

    The 2013 ISI journal rankings are out and it is my pleasure to inform our readership that CVIR ranks 43/120 (2012: 46/118) journals in the field of radiology. The 2013 impact factor further improved to 2.138 (2012: 2.093). This means that Cardiovascular and Interventional Radiology again continues to be the highest ranked journal dedicated to the field of interventional radiology in 2013.This is mainly due to the great support we achieve by you as authors and readers of CVIR, your dedication to the profession, and your loyalty both to the journal and to CIRSE. For all of this, we owe you our thanks and respect.

  13. Systematic Review of the Application of Lean and Six Sigma Quality Improvement Methodologies in Radiology.

    Science.gov (United States)

    Amaratunga, Thelina; Dobranowski, Julian

    2016-09-01

    Preventable yet clinically significant rates of medical error remain systemic, while health care spending is at a historic high. Industry-based quality improvement (QI) methodologies show potential for utility in health care and radiology because they use an empirical approach to reduce variability and improve workflow. The aim of this review was to systematically assess the literature with regard to the use and efficacy of Lean and Six Sigma (the most popular of the industrial QI methodologies) within radiology. MEDLINE, the Allied & Complementary Medicine Database, Embase Classic + Embase, Health and Psychosocial Instruments, and the Ovid HealthStar database, alongside the Cochrane Library databases, were searched on June 2015. Empirical studies in peer-reviewed journals were included if they assessed the use of Lean, Six Sigma, or Lean Six Sigma with regard to their ability to improve a variety of quality metrics in a radiology-centered clinical setting. Of the 278 articles returned, 23 studies were suitable for inclusion. Of these, 10 assessed Six Sigma, 7 assessed Lean, and 6 assessed Lean Six Sigma. The diverse range of measured outcomes can be organized into 7 common aims: cost savings, reducing appointment wait time, reducing in-department wait time, increasing patient volume, reducing cycle time, reducing defects, and increasing staff and patient safety and satisfaction. All of the included studies demonstrated improvements across a variety of outcomes. However, there were high rates of systematic bias and imprecision as per the Grading of Recommendations Assessment, Development and Evaluation guidelines. Lean and Six Sigma QI methodologies have the potential to reduce error and costs and improve quality within radiology. However, there is a pressing need to conduct high-quality studies in order to realize the true potential of these QI methodologies in health care and radiology. Recommendations on how to improve the quality of the literature are proposed

  14. Radiology education: a radiology curriculum for all medical students?

    Science.gov (United States)

    Zwaan, Laura; Kok, Ellen M; van der Gijp, Anouk

    2017-09-26

    Diagnostic errors in radiology are frequent and can cause severe patient harm. Despite large performance differences between radiologists and non-radiology physicians, the latter often interpret medical images because electronic health records make images available throughout the hospital. Some people argue that non-radiologists should not diagnose medical images at all, and that medical school should focus on teaching ordering skills instead of image interpretation skills. We agree that teaching ordering skills is crucial as most physicians will need to order medical images in their professional life. However, we argue that the availability of medical images is so ubiquitous that it is important that non-radiologists are also trained in the basics of medical image interpretation and, additionally in recognizing when radiological consultancy should be sought. In acute situations, basic image interpretations skills can be life-saving. We plead for a radiology curriculum for all medical students. This should include the interpretation of common abnormalities on chest and skeletal radiographs and a basic distinction of normal from abnormal images. Furthermore, substantial attention should be given to the correct ordering of radiological images. Finally, it is critical that students are trained in deciding when to consult a radiologist.

  15. Demonstration of mobile radiation monitoring methodology for quick assessment of radiological impact of Mumbai City Using road, rail and sea routes

    International Nuclear Information System (INIS)

    Chatterjee, M.K.; Divkar, J.K.; Singh, Rajvir; Pradeepkumar, K.S.; Sharma, D.N.

    2008-01-01

    The study of background radiation levels by suitable mobile monitoring methodology through different routes (road, rail and sea) with the help of state of the art monitoring systems has been initiated with an objective to demonstrate the effectiveness of monitoring methodologies for quick radiological impact assessment during any radiological emergency and to detect the presence of orphan source(s), if any. The other objective was to establish a reliable base line data on the background radiation levels. The study was carried out in Mumbai city through different available routes. Mumbai is a densely populated city and everyday millions of commuters are crossing across the city using rail and road routes. In case of any unwarned radiological emergency in public domain, a large section of people of the city may get concerned of radioactive contamination/ high radiation exposure. In such scenario, environmental radiation monitoring and quick assessment of contamination in public domain will be a challenging task for the civil authorities. The monitoring techniques used for quick radiological impact assessment and the established base line dose rate data of Mumbai city will be very useful for planning counter measures, if required. During mobile monitoring programme of this highly populated city, the monitoring routes, selection and placement of different monitoring instruments/system within the mobile platform, data acquisition time of the respective monitoring equipments, speed of mobile monitoring station etc were optimized. State-of-the-art systems like Portable Mobile Gamma Spectrometry System (PMGSS), Compact Radiation Monitoring System integrated with GPS, Gammatracers, Portable low/high range survey meters and hand held spectrometers were used. The average of the dose rates recorded during monitoring through road routes and railway routes of Mumbai city were 60±10 nGy.h -1 and 65±15 nGy.h -1 respectively, which are attributable to terrestrial and cosmic

  16. Radiation protection and quality assurance in dental radiology: II. Panoramic radiology

    International Nuclear Information System (INIS)

    Jodar-Porlan, S.; Alcaraz, M.; Martinez-Beneyto, Y.; Saura-Iniesta, A.M.; Velasco-Hidalgo, E.

    2001-01-01

    This paper studies 278 official reports on quality assurance in dental radiology in the context of the first revision of these dental clinics, as a result of the entry into force of the regulations establishing the duties for these types of facilities. In the results section we present a quantitative analysis of the facilities equipped with an panoramic radiology apparatus, making a special reference to the brands they have available, as well as their physical features (kV, mA, filtration) and the deviations detected in their operation. Some of their features in the process of obtaining radiological images at those facilities (film control, development time, liquid renewal) are determined, and the average dose of ionising radiation used in order to obtain the same tooth radiological image is presented. This paper shows, in a quantitative way, the characteristic features of panoramic radiology in our medium. The study is intended to be continued during the next years, which would allow the assessment of the prospective improvement in dental radiological performances as a result of the newly established regulations. (author)

  17. Radiology education: a radiology curriculum for all medical students?

    NARCIS (Netherlands)

    Zwaan, Laura; Kok, E.M.; van der Gijp, Anouk

    2017-01-01

    Diagnostic errors in radiology are frequent and can cause severe patient harm. Despite large performance differences between radiologists and non-radiology physicians, the latter often interpret medical images because electronic health records make images available throughout the hospital. Some

  18. Radiological optimization

    International Nuclear Information System (INIS)

    Zeevaert, T.

    1998-01-01

    Radiological optimization is one of the basic principles in each radiation-protection system and it is a basic requirement in the safety standards for radiation protection in the European Communities. The objectives of the research, performed in this field at the Belgian Nuclear Research Centre SCK-CEN, are: (1) to implement the ALARA principles in activities with radiological consequences; (2) to develop methodologies for optimization techniques in decision-aiding; (3) to optimize radiological assessment models by validation and intercomparison; (4) to improve methods to assess in real time the radiological hazards in the environment in case of an accident; (5) to develop methods and programmes to assist decision-makers during a nuclear emergency; (6) to support the policy of radioactive waste management authorities in the field of radiation protection; (7) to investigate existing software programmes in the domain of multi criteria analysis. The main achievements for 1997 are given

  19. Reducing the impact.

    Science.gov (United States)

    Mahathir, M

    1997-01-01

    In Asia, attempts to control HIV/AIDS through education have not achieved the necessary behavior changes. This is especially true for young women who are unable to apply their knowledge to their sex behavior because of inequalities in gender relations. Thus, the impact of AIDS on women is significantly greater in settings where the status of women is low. Women in developing countries are at greatest risk because the epidemic is fueled by poverty, lack of information, and lack of autonomy. Prosperity in a developing country, such as Malaysia, entails its own risks because it creates new social norms and values that exist in tandem with debilitating old norms, such as the patriarchy that disempowers women and a resurgence in polygamy and wife abandonment. Subservient gender roles not only increase women's chances of infection, they also target women as the primary caregivers for infected individuals. Young girls may have to abandon school to care for infected parents, and female health care providers are assigned to the lowest ranks of the profession. While most women have been infected by their husbands, they must also bear the stigma of being considered immoral infectors of their husbands. The futures of AIDS widows and orphans is jeopardized by the discrimination that attends the disease, and if the mother dies, her young children face a higher death rate. In settings new to the epidemic, it is difficult to convince men of the importance of addressing women's needs and of seeking the input of women in policy and program development. Only by empowering both sexes to work together to protect society will there be a reasonable chance of reducing the impact of HIV/AIDS.

  20. Investigation of the radiological impact due to the dredging of sediments in the Minimes harbour of La Rochelle. Workers and population exposure to reinforced natural radioactivity

    International Nuclear Information System (INIS)

    2010-01-01

    As the city of La Rochelle is implementing a project of expansion of the Minimes yachting harbour which comprises the dredging of sediments (which may have been polluted by a rare earth production plant), this document reports the assessment of the radiological impact of this dredging activity on workers and on the population. A campaign of sediment coring has been performed in order to validate the reference coring station selection, to measure sand radiological activity and to measure the activity of the sediments to be dredged. The computed maximum efficient doses for the workers and for the population appear to be low, and very much less to the 1 mSv/year threshold

  1. Radiology systems architecture.

    Science.gov (United States)

    Deibel, S R; Greenes, R A

    1996-05-01

    This article focuses on the software requirements for enterprise integration in radiology. The needs of a future radiology systems architecture are examined, both at a concrete functional level and at an abstract system-properties level. A component-based approach to software development is described and is validated in the context of each of the abstract system requirements for future radiology computing environments.

  2. New era of the relationship between Chinese interventional radiology sub-society and journal of interventional radiology

    International Nuclear Information System (INIS)

    Li Linsun

    2009-01-01

    The past decades have witnessed interventional radiology in China to go from a very initial clinical practice to an important medical player in modern medicine. Recently, a friendly collaboration has been successfully established between the Chinese Interventional Radiology Sub-society and the Journal of Interventional Radiology. The Chinese Interventional Radiology Sub-society will take the full responsibility for the academic governance of the Journal of Interventional Radiology and the Journal of Interventional Radiology will formally become the sole interventional academic periodical of the Chinese Interventional Radiology Sub-society in China. This collaboration will surely make Chinese interventional radiology to initiate a new era,promote the further development of interventional radiology at home and enable the Journal of Interventional Radiology to step into the international medical circle. (authors)

  3. The Influence of atmospheric conditions to probabilistic calculation of impact of radiology accident on PWR 1000 MWe

    International Nuclear Information System (INIS)

    Pande Made Udiyani; Sri Kuntjoro

    2015-01-01

    The calculation of the radiological impact of the fission products releases due to potential accidents that may occur in the PWR (Pressurized Water Reactor) is required in a probabilistic. The atmospheric conditions greatly contribute to the dispersion of radionuclides in the environment, so that in this study will be analyzed the influence of atmospheric conditions on probabilistic calculation of the reactor accidents consequences. The objective of this study is to conduct an analysis of the influence of atmospheric conditions based on meteorological input data models on the radiological consequences of PWR 1000 MWe accidents. Simulations using PC-Cosyma code with probabilistic calculations mode, the meteorological data input executed cyclic and stratified, the meteorological input data are executed in the cyclic and stratified, and simulated in Muria Peninsula and Serang Coastal. Meteorological data were taken every hour for the duration of the year. The result showed that the cumulative frequency for the same input models for Serang coastal is higher than the Muria Peninsula. For the same site, cumulative frequency on cyclic input models is higher than stratified models. The cyclic models provide flexibility in determining the level of accuracy of calculations and do not require reference data compared to stratified models. The use of cyclic and stratified models involving large amounts of data and calculation repetition will improve the accuracy of statistical calculation values. (author)

  4. The clinical impact of the radiology report in wheezing and nonwheezing febrile children: a survey of clinicians

    Energy Technology Data Exchange (ETDEWEB)

    Spottswood, Stephanie E.; Hernanz-Schulman, Marta; Hilmes, Melissa A.; Kan, J.H. [Vanderbilt University, Department of Radiology and Radiological Sciences, Monroe Carell Jr. Children' s Hospital, Nashville, TN (United States); Liaw, Kevin [Vanderbilt University School of Medicine, Nashville, TN (United States); Moore, Paul E. [Vanderbilt University, Department of Pediatric Pulmonary, Allergy and Immunology, Monroe Carell Jr. Children' s Hospital, Nashville, TN (United States); Patterson, Barron [Vanderbilt University, Department of Pediatrics, Monroe Carell Jr. Children' s Hospital, Nashville, TN (United States); Chen, Heidi [Vanderbilt University Medical Center, Department of Biostatistics, Nashville, TN (United States)

    2009-04-15

    The chest radiograph is commonly used in the diagnosis and management of patients presenting with respiratory illness. The language used to describe the findings is important to ensure appropriate communication with the referring clinician and thereby optimize patient management. In this study we attempted to determine how clinicians interpret specific terms commonly used in a chest radiograph report, and to assess how these terms impact the management of children with respiratory symptoms. An online survey was distributed to 562 pediatric practitioners asking their interpretation of the terms ''peripheral airway disease (PAD),'' ''focal airspace consolidation,'' and ''focal infiltrate'' in a febrile child with or without wheezing. There were 112 respondents. Most practitioners defined the term ''PAD'' as viral pneumonia (61.5%) or asthma (56.9%), ''consolidation'' as atelectasis (83%) followed by pneumonia (69.6%), and ''infiltrate'' as pneumonia (100%), followed by atelectasis (22.3%). Practitioners were more likely to treat a nonwheezing child with antibiotics if the report stated ''focal airspace consolidation'' (80%) or ''focal infiltrate'' (100%; P=0.001). Some radiologic descriptors may lead to diverse and sometimes unintended diagnostic conclusions. Our findings support continued effort to structure and standardize the radiology report and our descriptive terminology. (orig.)

  5. The concept of error and malpractice in radiology.

    Science.gov (United States)

    Pinto, Antonio; Brunese, Luca; Pinto, Fabio; Reali, Riccardo; Daniele, Stefania; Romano, Luigia

    2012-08-01

    Since the early 1970s, physicians have been subjected to an increasing number of medical malpractice claims. Radiology is one of the specialties most liable to claims of medical negligence. The etiology of radiological error is multifactorial. Errors fall into recurrent patterns. Errors arise from poor technique, failures of perception, lack of knowledge, and misjudgments. Every radiologist should understand the sources of error in diagnostic radiology as well as the elements of negligence that form the basis of malpractice litigation. Errors are an inevitable part of human life, and every health professional has made mistakes. To improve patient safety and reduce the risk from harm, we must accept that some errors are inevitable during the delivery of health care. We must play a cultural change in medicine, wherein errors are actively sought, openly discussed, and aggressively addressed. Copyright © 2012 Elsevier Inc. All rights reserved.

  6. Procedures in diagnostic radiology

    International Nuclear Information System (INIS)

    Doyle, T.; Hare, W.S.C.; Thomson, K.; Tess, B.

    1989-01-01

    This book outlines the various procedures necessary for the successful practice of diagnostic radiology. Topics covered are: general principles, imaging of the urinary and gastrointestinal tracts, vascular radiology, arthrography, and miscellaneous diagnostic radiologic procedures

  7. ESR concept paper on value-based radiology.

    Science.gov (United States)

    2017-10-01

    The European Society of Radiology (ESR) established a Working Group on Value-Based Imaging (VBI WG) in August 2016 in response to developments in European healthcare systems in general, and the trend within radiology to move from volume- to value-based practice in particular. The value-based healthcare (VBH) concept defines "value" as health outcomes achieved for patients relative to the costs of achieving them. Within this framework, value measurements start at the beginning of therapy; the whole diagnostic process is disregarded, and is considered only if it is the cause of errors or complications. Making the case for a new, multidisciplinary organisation of healthcare delivery centred on the patient, this paper establishes the diagnosis of disease as a first outcome in the interrelated activities of the healthcare chain. Metrics are proposed for measuring the quality of radiologists' diagnoses and the various ways in which radiologists provide value to patients, other medical specialists and healthcare systems at large. The ESR strongly believes value-based radiology (VBR) is a necessary complement to existing VBH concepts. The Society is determined to establish a holistic VBR programme to help European radiologists deal with changes in the evolution from volume- to value-based evaluation of radiological activities. Main Messages • Value-based healthcare defines value as patient's outcome over costs. • The VBH framework disregards the diagnosis as an outcome. • VBH considers diagnosis only if wrong or a cause of complications. • A correct diagnosis is the first outcome that matters to patients. • Metrics to measure radiologists' impacts on patient outcomes are key. • The value provided by radiology is multifaceted, going beyond exam volumes.

  8. Socioeconomic trends in radiology

    International Nuclear Information System (INIS)

    Barneveld Binkhuysen, F.H.

    1998-01-01

    For radiology the socioeconomic environment is a topic of increasing importance. In addition to the well-known important scientific developments in radiology such as interventional MRI, several other major trends can be recognized: (1) changes in the delivery of health care, in which all kinds of managed care are developing and will influence the practice of radiology, and (2) the process of computerization and digitization. The socioeconomic environment of radiology will be transformed by the developments in managed care, teleradiology and the integration of information systems. If radiologists want to manage future radiology departments they must have an understanding of the changes in the fields of economics and politics that are taking place and that will increasingly influence radiology. Some important and recognizable aspects of these changes will be described here. (orig.)

  9. Decision Strategy: Radiological Evaluations: Air

    International Nuclear Information System (INIS)

    Sohier, A.

    2000-01-01

    The objectives of SCK-CEN's R and D programme on off-site emergency management are (1) to improve methods to assess in real time the radiological impact to the population and the environment during a nuclear emergency; (2) to support and advise the Belgian authorities on specific problems concerning existing and potential hazards from exposure to ionising radiation in normal and accidental conditions; (3) to organise training courses on off-site emergency response to nuclear accidents. Main achievements in 1999 are reported on

  10. Radiological review of accident and emergency radiographs: A 1-year audit

    International Nuclear Information System (INIS)

    Williams, Stuart M.; Connelly, Daniel J.; Wadsworth, Susan; Wilson, David

    2000-01-01

    AIM: To assess the impact and cost effectiveness of a system of radiological review of accident and emergency (A and E) plain films. MATERIALS AND METHODS: Review documentation was studied retrospectively over a 1-year period. Six hundred and eighty-four actual or suspected errors in the initial radiological interpretation by A and E staff were highlighted by radiologists in training. These selected 'red reports' were then further reviewed by a musculoskeletal radiologist and a more senior member of the A and E team. RESULTS: Three hundred and fifty-one missed or strongly suspected fractures were detected, with ankle, finger and elbow lesions predominating. Other errors included 11 missed chest radiograph abnormalities and 24 A and E false-positives. Radiologists in training tended to over-report abnormalities with an 18% false-positive rate when compared to the subsequent musculoskeletal radiology opinion. Following review, further action was taken by A and E staff in 286 (42.6%) of cases. No operative intervention was required in those patients with a delayed or missed A and E diagnosis. Consideration is given to the cost of providing this form of review and the impact of medico-legal factors. CONCLUSION: Compared with the large numbers of patients seen and radiographed in a busy A and E department, the number of radiological errors was small. There were even fewer changes in management. Despite this, concern over litigation, clinical governance and future work patterns in A and E make this form of review a useful means of risk reduction in a teaching hospital. Williams, S.M. (2000). Clinical Radiology 55, 861-865

  11. Discharges of nuclear waste into the Kola Bay and its impact on human radiological doses

    International Nuclear Information System (INIS)

    Matishov, Genady G.; Matishov, Dimitry G.; Namjatov, Alexey A.; Carroll, JoLynn; Dahle, Salve

    2000-01-01

    The civilian nuclear icebreaker facility, RTP ''ATOMFLOT,'' is located in Kola Bay, Northwest Russia, as are several nuclear installations operated by the Russian Northern Fleet. A treatment plant at the Atomflot facility discharges purified nuclear waste into the bay at an annual rate of 500 m 3 . As a result of plant modifications this rate will soon increase to 5000 m 3 /yr. Evidence of minor leakages of 60 Co are reported by in the vicinity of Atomflot as well as near several military installations in Kola and the adjacent Motovsky Bays. 137 Cs levels reported in the present study for seawater and seaweed collected from locations within the bays are at expected levels except in the vicinity of Atomflot, where the 137 Cs level in a seaweed sample was 46±5 Bq/kg w.w. indicating significant uptake of radionuclides to biota. Uptake also may be occurring in higher trophic levels of the food web through environmental exchange and/or biotransformation. We consider the impact of the present and anticipated discharges from Atomflot through a radiological dose assessment for humans consuming fish from Kola Bay. Mixing and transport of nuclear waste is simulated using a simple box model. Maximum doses, assuming consumption of 100 kg/yr of fish, are below 10 -9 Sv/yr; the planned ten-fold increase in the discharge of treated waste will increase the doses to below 10 -8 Sv/yr. Using data on radionuclide levels in sediments and assuming equilibrium partitioning of radionuclides among sediment, seawater and fish, we estimate that the total doses to humans consuming fish from different areas of Kola and Motovsky Bays, including adjacent to military-controlled nuclear installations, are ∼10 -7 Sv/yr. Nuclear activities in Kola and Motovsky Bays thus far have had minimal impact on the environment. Discharges from the treatment plant currently account for less than 0.2% of the total dose predictions. The increase in discharges from the treatment plant is not expected to change

  12. Radiological impact of phosphogypsum in the Surrounding Ecosystem

    International Nuclear Information System (INIS)

    Al-Attar, L.; Al-Oudat, M.; Budier, Y.; Khalili, H.; Hamwi, A.; Kanakri, S.

    2011-01-01

    This study was carried out to assess the radiological impact of Syrian PG piles in the compartments of the surrounding ecosystem. Therefore, estimating the distribution of naturally occurring radionuclides (i.e. 2 26 Ra, 2 38 U, 2 32 Th, 2 10 Po and 2 10 Pb) in the raw materials, product and by-product of the Syrian phosphate fertilizer industry was essential. The obtained data revealed that 2 26 Ra retained in PG with a mean activity of 318 Bq kg-1. Uranium content in PG was low since it remained in the produced phosphoric acid. However, over 80% of 2 32 Th, 2 10 Po and 2 10 Pb partitioned in PG. The presence of PG piles did not increase the concentration of 2 22 Rn nor gamma rays exposure dose in the studied area. The annual effective dose was only 0.082 mSv y-1. The geometric mean of total suspended solids was ca. 85 g m-3. The concentration of the radionuclides in filtration and runoff waters were below the detection limits; and were much lower than the permissible limits set for drinking water by the WHO in ground and Qattina Lake waters. Eastern sites soil samples of PG piles were of the highest activity concentrations, due to the characterised western and north-western wind in the area, but remained within the natural levels reported in Syrian soil. The impact of PG piles on plants varied upon the plant species. Significantly, higher concentrations of the radionuclides were recorded for grass in comparison to broad-leaved plants. Among the species that naturally grown on PG piles, Inula, Ecballium and Polygonium may be radionuclides accumulators. Nevertheless, a determined effort is needed on national level to achieve a common and coherent approach to regulate PG piles or to consider it a resource material rather than waste or residue. The presence of PG piles did not increase the concentration of 2 22 Rn nor gamma rays exposure dose in the studied area. The annual effective dose was only 0.082 mSv y -1 . The geometric mean of total suspended solids was ca

  13. Dosimetry in Diagnostic Radiology for Paediatric Patients

    International Nuclear Information System (INIS)

    2013-01-01

    Concern about the radiation dose to children from diagnostic radiology examinations has recently been popularly expressed, particularly as related to computed tomography (CT) procedures. This involves the observation that children can receive doses far in excess of those delivered to adults, in part due to the digital nature of the image receptors that may give no warning to the operator of the dose to the patient. Concern for CT examinations should be extended to the broad range of paediatric diagnostic radiological procedures responsible for radiation doses in children, especially as factors, such as increased radiosensitivity and the longer life expectancy of children, increase the associated radiation risk. In all cases, owing to the added paediatric radiological examination factor of patient size and its associated impact on equipment selection, clinical examination protocol and dosimetric audit, the determination of paediatric dose requires a distinct approach from adult dosimetry associated with diagnostic radiological examinations. In response to this, there is a need to inform health professionals about standardized methodologies used to determine paediatric dose for all major modalities such as general radiography, fluoroscopy and CT. Methodologies for standardizing the conduct of dose audits and their use for the derivation and application of diagnostic reference levels for patient populations, that vary in size, are also required. In addition, a review is needed of the current knowledge on risks specific to non-adults from radiation, and also an analysis of the management of factors contributing to dose from paediatric radiological examinations. In 2007, the IAEA published a code of practice, Dosimetry in Diagnostic Radiology: An International Code of Practice, as Technical Reports Series No. 457 (TRS 457). TRS 457 recommends procedures for dosimetric measurement and calibration for the attainment of standardized dosimetry, and addresses requirements

  14. Uncited Research Articles in Popular United States General Radiology Journals.

    Science.gov (United States)

    Rosenkrantz, Andrew B; Chung, Ryan; Duszak, Richard

    2018-05-03

    This study aimed to characterize articles in popular general radiology journals that go uncited for a decade after publication. Using the Web of Science database, we identified annual citation counts for 13,459 articles published in Radiology, American Journal of Roentgenology, and Academic Radiology between 1997 and 2006. From this article cohort, we then identified all original research articles that accrued zero citations within a decade of publication. A concurrent equal-sized cohort of most cited articles was created. Numerous characteristics of the uncited and most cited articles were identified and compared. Only 47 uncited articles went uncited for a decade after publication. When compared to the 47 most cited articles over that same window, the uncited articles were significantly (P articles, uncited articles also had significantly (P articles published in popular general radiology journals, only a very small number of original research investigations remained uncited a decade after publication. Given that citations reflect the impact of radiology research, this observation suggests that journals are appropriately selecting meaningful work. Investigators seeking to avoid futile publication might consider their research initiatives in light of these characteristics. Copyright © 2018 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  15. Compilation of historical radiological data collected in the vicinity of the WIPP site

    International Nuclear Information System (INIS)

    Bradshaw, P.L.; Louderbough, E.T.

    1987-01-01

    The Radiological Baseline Program (RBP) at the Waste Isolation Pilot Plant (WIPP) has been implemented to characterize the radiological conditions at the site prior to receipt of radioactive wastes. Because southeastern New Mexico was the site of an underground nuclear test in 1961, various sampling programs have intermittently monitored background and elevated radiation levels in the vicinity of the WIPP. In addition, radiological characterization of the site region was performed during the 1970's in support of the WIPP Environmental Impact Statement. The historical data are drawn primarily from monitoring activities of the US Public Health Service (PHS), the Environmental Protection Agency (EPA), US Geological Survey (USGS) and Sandia National Laboratories, Albuquerque (SNLA). Information on air and water quality, meat, milk, biota and vegetation is included in the report. This survey is intended to provide a source of reference for historical data on radiological conditions in the vicinity of the WIPP site prior to the establishment of a systematic Radiological Baseline Program. 31 refs., 1 fig

  16. Impact of ICRP 117 recommendations in the operational protection of vascular radiology unit

    International Nuclear Information System (INIS)

    Gomez, Pablo Luis; Fernandez, Manuel; Verde, Jose Maria; Perez, Maria Esperanza; Gomez, Nuria

    2013-01-01

    This paper lists and discusses the results obtained in the teams of the different specialties: traumatology, gastroenterology, hemodynamics, vascular radiology and neurosurgery at different care centres with various care portfolios and notable differences of technical resources. The results show a noticeable difference between the equipment used in gastroenterology, vascular radiology and hemodynamic reference services with other services and disciplines. Taking into account the recent 117 of ICRP publication it has been initiated a procedure for the estimation of dose of foot and ankle of the vascular radiologists and in crystalline. This paper shows the results obtained as well as the correlations between the mentioned area dose and values of dose of lapel, wrist, ankles and crystalline of the professionals

  17. Dental radiology

    International Nuclear Information System (INIS)

    Bhaskar, S.N.

    1982-01-01

    The book presents the radiological manifestations of the maxillodental region in a suitable manner for fast detection and correct diagnosing of diseases of the teeth, soft tissue, and jaws. Classification therefore is made according to the radiological manifestations of the diseases and not according to etiology. (orig./MG) [de

  18. Medical radiation exposure and its impact on occupational practices in Korean radiologic technologists

    Energy Technology Data Exchange (ETDEWEB)

    Ko, Seul Ki; Lee, Won Jin [Dept. of Preventive Medicine, Korea University College of Medicine, Seoul (Korea, Republic of)

    2016-12-15

    The use of radiology examinations in medicine has been growing worldwide. Annually an estimated 3.1 billion radiologic exams are performed. According to this expansion of medical radiation exposure, it has been hard to pay no attention to the effects of medical radiation exposures in the exposure from different types of radiation source. This study, therefore, was aimed to assess the association of medical and occupational radiation exposure in Korean radiologic technologists and evaluate necessity for its consideration in occupational studies. This study did not show the strong association between medical radiation exposure and occupational radiation exposure except several modalities with specific frequency. These results are preliminary but certainly meaningful for interpretation of epidemiologic finding, therefore, we need further evaluation specially for the repeatedly exposed imaging tests and high dose procedures that presented somewhat weak relationship in this study linked with health outcomes of radiation exposure. This study did not show the strong association between medical radiation exposure and occupational radiation exposure except several modalities with specific frequency. These results are preliminary but certainly meaningful for interpretation of epidemiologic finding, therefore, we need further evaluation specially for the repeatedly exposed imaging tests and high dose procedures that presented somewhat weak relationship in this study linked with health outcomes of radiation exposure.

  19. Medical radiation exposure and its impact on occupational practices in Korean radiologic technologists

    International Nuclear Information System (INIS)

    Ko, Seul Ki; Lee, Won Jin

    2016-01-01

    The use of radiology examinations in medicine has been growing worldwide. Annually an estimated 3.1 billion radiologic exams are performed. According to this expansion of medical radiation exposure, it has been hard to pay no attention to the effects of medical radiation exposures in the exposure from different types of radiation source. This study, therefore, was aimed to assess the association of medical and occupational radiation exposure in Korean radiologic technologists and evaluate necessity for its consideration in occupational studies. This study did not show the strong association between medical radiation exposure and occupational radiation exposure except several modalities with specific frequency. These results are preliminary but certainly meaningful for interpretation of epidemiologic finding, therefore, we need further evaluation specially for the repeatedly exposed imaging tests and high dose procedures that presented somewhat weak relationship in this study linked with health outcomes of radiation exposure. This study did not show the strong association between medical radiation exposure and occupational radiation exposure except several modalities with specific frequency. These results are preliminary but certainly meaningful for interpretation of epidemiologic finding, therefore, we need further evaluation specially for the repeatedly exposed imaging tests and high dose procedures that presented somewhat weak relationship in this study linked with health outcomes of radiation exposure.

  20. A Checklist to Improve Patient Safety in Interventional Radiology

    International Nuclear Information System (INIS)

    Koetser, Inge C. J.; Vries, Eefje N. de; Delden, Otto M. van; Smorenburg, Susanne M.; Boermeester, Marja A.; Lienden, Krijn P. van

    2013-01-01

    To develop a specific RADiological Patient Safety System (RADPASS) checklist for interventional radiology and to assess the effect of this checklist on health care processes of radiological interventions. On the basis of available literature and expert opinion, a prototype checklist was developed. The checklist was adapted on the basis of observation of daily practice in a tertiary referral centre and evaluation by users. To assess the effect of RADPASS, in a series of radiological interventions, all deviations from optimal care were registered before and after implementation of the checklist. In addition, the checklist and its use were evaluated by interviewing all users. The RADPASS checklist has two parts: A (Planning and Preparation) and B (Procedure). The latter part comprises checks just before starting a procedure (B1) and checks concerning the postprocedural care immediately after completion of the procedure (B2). Two cohorts of, respectively, 94 and 101 radiological interventions were observed; the mean percentage of deviations of the optimal process per intervention decreased from 24 % before implementation to 5 % after implementation (p < 0.001). Postponements and cancellations of interventions decreased from 10 % before implementation to 0 % after implementation. Most users agreed that the checklist was user-friendly and increased patient safety awareness and efficiency. The first validated patient safety checklist for interventional radiology was developed. The use of the RADPASS checklist reduced deviations from the optimal process by three quarters and was associated with less procedure postponements.

  1. Radiological survey techniques for decontamination and dismantlement applications

    International Nuclear Information System (INIS)

    Ruesink, G.P.; Stempfley, D.H.; Pettit, P.J.; Warner, R.D.

    1997-01-01

    The Department of Energy's Fernald Environmental Management Project (FEMP) is engaged in an aggressive Program to remove all above ground structures as part of the Fernald sites final remediation remedy. Through the complete removal of major facilities such as Plant 7, Plant 4, and Plant 1, the FEMP has developed radiological survey approaches that are effective for the different phases of the Decontamination and Dismantlement (D ampersand D) process. Some of the most pressing challenges facing the FEMP are implementing effective, low cost methods for the D ampersand D of former process buildings while minimizing environmental effects. One of the key components to ensure minimal impact on the environment is the collection of radiological contamination information during the D ampersand D process to facilitate the decision making process. Prior to the final demolition of any structure, radiological surveys of floors, walls, and ceilings must take place. These surveys must demonstrate that contamination levels am below 5000 dpm removable beta/gamma for non-porous surfaces and below 1000 dpm removable-beta/gamma for all porous surfaces. Technique which can perform these activities in a safe, effective, and cost efficient manner are greatly desired. The FEMP has investigated new approaches to address this need. These techniques include sampling approaches using standard baseline methodology as well as innovative approaches to accelerate final radiological clearance processes. To further improve upon this process, the FEMP has investigated several new technologies through the Fernald Plant 1 Large Scale Technology Demonstration Project. One of the most promising of these new technologies, Laser Induced Fluorescence, may significantly improve the radiological clearance survey process. This paper will present real world experiences in applying radiological control limits to D ampersand D projects as well as relate potential productivity and cost improvements with the

  2. Environmental radiological impact of some Portuguese uranium mines

    International Nuclear Information System (INIS)

    Galvao, J.P.; Bettencourt, A.O.; Teixeira, M.M.G.R.; Elias, M.D.T.

    1988-01-01

    An environmental radiological surveillance programme has been in progress around the most significant Portuguese uranium mines, from 1976 to 1983. A short description is given of the mines of Urgeirica (including uranium milling), Freixiosa, Pinhal de Souto and Bica. The results of the surveillance programme developed in the vicinity of these facilities are presented and the identified critical pathways are discussed. One of these pathways is the consumption of cabbage, which is an important component in the diet of the Portuguese population. The exposure of the critical groups, due to the intake of 226 Ra through the diet, calculated from the results of this monitoring programme, range from 0.02 to 1.5 mSv.y -1 for the different mines under study. (author)

  3. White Paper: Curriculum in Interventional Radiology.

    Science.gov (United States)

    Mahnken, Andreas H; Bücker, Arno; Hohl, Christian; Berlis, Ansgar

    2017-04-01

    Purpose  Scope and clinical importance of interventional radiology markedly evolved over the last decades. Consequently it was acknowledged as independent subspecialty by the "European Union of Medical Specialists" (UEMS). Based on radiological imaging techniques Interventional Radiology is an integral part of Radiology. Materials und Methods  In 2009 the German Society for Interventional Radiology and minimally-invasive therapy (DeGIR) developed a structured training in Interventional Radiology. In cooperation with the German Society of Neuroradiology (DGNR) this training was extended to also cover Interventional Neuroradiology in 2012. Tailored for this training in Interventional Radiology a structured curriculum was developed, covering the scope of this modular training. Results  The curriculum is based on the DeGIR/DGNR modular training concept in Interventional Radiology. There is also an European Curriculum and Syllabus for Interventional Radiology developed by the "Cardiovascular and Interventional Radiological Society of Europe" (CIRSE). The presented curriculum in Interventional Radiology is designed to provide a uniform base for the training in Interventional Radiology in Germany, based on the competencies obtained during residency. Conclusion  This curriculum can be used as a basis for training in Interventional Radiology by all training sites. Key Points: · Interventional Radiology is an integral part of clinical radiology. · The German Society for Interventional Radiology and minimally-invasive therapy (DeGIR) developed a curriculum in Interventional Radiology. · This curriculum is an integrative basis for the training in interventional. Citation Format · Mahnken AH, Bücker A, Hohl C et al. White Paper: Curriculum in Interventional Radiology. Fortschr Röntgenstr 2017; 189: 309 - 311. © Georg Thieme Verlag KG Stuttgart · New York.

  4. Radiological Evaluation of phosphate fertilizers used in Tunisia

    International Nuclear Information System (INIS)

    Jemli, Khaoula

    2010-01-01

    The need of control of natural radioactivity in the environment and the radiological impact of the use of chemical fertilizers has led us in this work to measure the natural radioactivity of the phosphate fertilizers in Tunisia. The distribution of various radionuclides during their manufacturing process of fertilizers is also part of this work.

  5. Ten years after the radiological accident of Goiania, a reflection

    International Nuclear Information System (INIS)

    Nouailhetas, Y.; Xavier, A.M.

    1998-01-01

    This work contains a reflection on the impact of the radiological protection measures taken in the city of Goiania in the aftermath of the accident involving caesium-137, along with a discussion on the biological foundation of these actions. (author)

  6. Quality management in a department of radiology

    International Nuclear Information System (INIS)

    Fischer, U.; Vosshenrich, R.; Baum, F.; Schorn, C.; Funke, M.; Grabbe, E.; Strasser, G.; Staudacher, J.

    2002-01-01

    Purpose. To increase the quality of internal and external interactions (patients, clinical colleagues, technicians, radiologists) in a department of radiology.Method. Accompanied by a well-experienced adviser workshops have been performed dealing with different topics like ''contact to patients'', ''performance of the radiological report and interaction with the referring colleague'' or ''research and teaching''. A catalogue of different actions was defined to reduce hindrances within the internal and external work-flow.Results. A total number of 53 actions was defined and related to different persons who were responsible for the realisation of the measures within a time interval. Six months after starting the quality management 46 (86%) of the defined actions were realised successfully, and another 4 (8%) measures were still running. There was a moderate increase of satisfaction of the patients and clinical colleagues considering the waiting time.Conclusions. A quality management in a radiological department allows an optimisation of the internal and external interactions. However, the guidance of a well-experienced adviser is as essential as the continuous control of successful finished measures. (orig.) [de

  7. Radiological protection

    International Nuclear Information System (INIS)

    Azorin N, J.; Azorin V, J. C.

    2010-01-01

    This work is directed to all those people related with the exercise of the radiological protection and has the purpose of providing them a base of knowledge in this discipline so that they can make decisions documented on technical and scientist factors for the protection of the personnel occupationally exposed, the people in general and the environment during the work with ionizing radiations. Before de lack of a text on this matter, this work seeks to cover the specific necessities of our country, providing a solid presentation of the radiological protection, included the bases of the radiations physics, the detection and radiation dosimetry, the radiobiology, the normative and operational procedures associates, the radioactive wastes, the emergencies and the transport of the radioactive material through the medical and industrial applications of the radiations, making emphasis in the relative particular aspects to the radiological protection in Mexico. The book have 16 chapters and with the purpose of supplementing the given information, are included at the end four appendixes: 1) the radioactive waste management in Mexico, 2-3) the Mexican official standards related with the radiological protection, 4) a terms glossary used in radiological protection. We hope this book will be of utility for those people that work in the investigation and the applications of the ionizing radiations. (Author)

  8. International scaling of nuclear and radiological events

    International Nuclear Information System (INIS)

    Wang Yuhui; Wang Haidan

    2014-01-01

    Scales are inherent forms of measurement used in daily life, just like Celsius or Fahrenheit scales for temperature and Richter for scale for earthquakes. Jointly developed by the IAEA and OECD/NEA in 1990, the purpose of International Nuclear and Radiological Event Scale (INES) is to help nuclear and radiation safety authorities and the nuclear industry worldwide to rate nuclear and radiological events and to communicate their safety significance to the general public, the media and the technical community. INES was initially used to classify events at nuclear power plants only. It was subsequently extended to rate events associated with the transport, storage and use of radioactive material and radiation sources, from those occurring at nuclear facilities to those associated with industrial use. Since its inception, it has been adopted in 69 countries. Events are classified on the scale at seven levels: Levels 1-3 are called 'incidents' and Levels 4-7 'accidents'. The scale is designed so that the severity of an event is about ten times greater for each increase in level on the scale. Events without safety significance are called 'deviations' and are classified Below Scale/Level 0. INES classifies nuclear and radiological accidents and incidents by considering three areas of impact: People and the Environment; Radiological Barriers and Control; Defence-in-Depth. By now, two nuclear accidents were on the highest level of the scale: Chernobyl and Fukumashi. (authors)

  9. Radiology trainer. Musculoskeletal system

    International Nuclear Information System (INIS)

    Staebler, A.; Erlt-Wagner, B.

    2006-01-01

    This book enables students to simulate examinations. The Radiology Trainer series comprises the whole knowledge of radiology in the form of case studies for self-testing. It is based on the best-sorted German-language collection of radiological examinations of all organ regions. Step by step, radiological knowledge is trained in order to make diagnoses more efficient. The book series ensures optimal preparation for the final medical examinations and is also a valuable tool for practical training. (orig.)

  10. Studies on optimization of radiation protection for patients in diagnostic radiology

    International Nuclear Information System (INIS)

    Wei, Z.; Zhang, Q.; Li, W.; Li, K.; Wei, L.; Zong, X.; Qiang, Z.; Wu, Y.

    1994-01-01

    For the exposure of patients in diagnostic radiology, individual dose limit does not apply, but optimization of radiological protection may play a major role. This project has been carried out with the purpose of improving the protection of patients in medical diagnostic radiology in China utilizing the principles of optimization. Taking Sichuan, Shandong and Beijing as surveyed areas, we investigated the present situation of the protection of patients. In the survey, the patient doses were classified into practical dose, justified dose and optimized dose to evaluate the influences of managerial and equipment factors separately. The results show that there are some urgent protection problems in X-ray protection to be solved in the surveyed regions. This paper, however, points out that the prospects of reducing patient doses are encouraging provided that appropriate measures are adopted. For instance, taking proper managerial measures without radical change of existing equipments may reduce patient doses in chest fluoroscopy and radiography by 40% and 18% respectively; refitting some equipment may reduce the doses by 82.4% in chest fluoroscopy, 66% in chest radiography, and 80% in barium meal examination of the gastrointestinal (GI) tract. Using chest radiography instead of fluoroscopy supplemented by other protection measures may reduce the doses by 91.7%. Optimization analysis shows that adoption of the above measures conforms to the principle of optimization of radiation protection. (authors). 5 refs., 7 tabs

  11. Radiological mapping of Mumbai-Chatrapur (Odisha) rail route

    International Nuclear Information System (INIS)

    Patra, R.P.; Patil, S.S.; Murali, S.; Singh, Rajvir; Pradeepkumar, K.S.

    2014-01-01

    The radiation mapping at various stations along Mumbai-Chatrapur rail route was carried out using GM, Plastic scintillator and NaI(Tl) based detectors. It has been observed that the average radiation level during the entire Mumbai-Chatrapur rail route was 63.8±6.l nSv h -1 and the maximum dose rate was 94.5±12.7 nSv h -1 and 103.2±10.2 nSv h -1 near Secunderabad and Chatrapur station respectively. The elevated radiation level at few locations was mainly due to the presence of terrestrial radiation i.e. naturally occurring radioactive material (NORM) viz., Thorium ( 232 Th) and Potassium ( 40 K) present in the environment. The spectral analysis led to confirming the presence of 232 Th and 40 K at the places. The main aim of the work was to generate the country wide baseline radiological data along selected important rail routes that could be used for radiological impact assessment. The results reported in this work would be helpful to provide valuable/useful reference data during the impact assessment at different locations

  12. Estimates of radiological risk from depleted uranium weapons in war scenarios.

    Science.gov (United States)

    Durante, Marco; Pugliese, Mariagabriella

    2002-01-01

    Several weapons used during the recent conflict in Yugoslavia contain depleted uranium, including missiles and armor-piercing incendiary rounds. Health concern is related to the use of these weapons, because of the heavy-metal toxicity and radioactivity of uranium. Although chemical toxicity is considered the more important source of health risk related to uranium, radiation exposure has been allegedly related to cancers among veterans of the Balkan conflict, and uranium munitions are a possible source of contamination in the environment. Actual measurements of radioactive contamination are needed to assess the risk. In this paper, a computer simulation is proposed to estimate radiological risk related to different exposure scenarios. Dose caused by inhalation of radioactive aerosols and ground contamination induced by Tomahawk missile impact are simulated using a Gaussian plume model (HOTSPOT code). Environmental contamination and committed dose to the population resident in contaminated areas are predicted by a food-web model (RESRAD code). Small values of committed effective dose equivalent appear to be associated with missile impacts (50-y CEDE radiological risk. These computer simulations suggest that little radiological risk is associated to the use of depleted uranium weapons.

  13. BNL ALARA Center's development of a computerized radiological assessment and design system (RADS)

    International Nuclear Information System (INIS)

    Dionne, B.J.; Masciulli, S.; Connelly, J.M.

    1993-01-01

    The US Department of Energy's (DOE) Office of Health Physics and Industrial Hygiene sponsored a study of Radiological Engineering Programs at selected DOE contractor facilities. This study was conducted to review, evaluate, and summarize techniques and practices that should be considered in the design phase that reduce dose and the spread of radioactive materials during subsequent construction and operation of DOE radiological facilities. As in a previous study on operational ALARA programs, a variety of good-practice documents will be generated. It is envisioned that these documents will serve as a resource to assist radiological engineers in the process of designing radiological facilities, and in performing radiological safety/ALARA design reviews. This paper presents the features for three good-practice documents and related software applications that are being developed based on the findings of this study. The proposed software called Radiological Assessment and Design System (RADS) will be a menu-driven database and spreadsheet program. It will be designed to provide easy, consistent, and effective implementation of the methodologies described in the three good-practice documents. These documents and the associated RADS software will provide the user with the following three functions: (1) enter dose assessment information and data into computer worksheets and provide printed tables of the results which can then be inserted into safety analysis reports or cost-benefit analyses, (2) perform a wide variety of sorts of radiological design criteria from DOE Orders and produce a checklist of the desired design criteria, and (3) enter cost/benefit data and qualitative rating of attributes for various design alternatives which reduce dose into computer worksheets and provide printed reports of cost-effectiveness results

  14. A survey of nurse staffing levels in interventional radiology units throughout the UK

    International Nuclear Information System (INIS)

    Christie, A.; Robertson, I.

    2016-01-01

    Aim: To supplement previous surveys analysing provision of interventional radiology (IR), in-hours (IH) and out-of-hours (OOH), by specifically surveying the level of nursing support provided. Materials and methods: A web-based questionnaire was distributed to all British Society of Interventional Radiology (BSIR) members. This addressed several aspects of radiology nursing support for IR procedures, both IH and OOH. Results: Sixty percent of respondents indicated that they have a formal OOH service. Of these, all have a dedicated nursing rota, with the vast majority operating with one nurse. IH, 77% of respondents always have a scrubbed nurse assistant, but this reduces to 40% OOH. IH, 4% never have a scrubbed radiology nurse assistant, which rises to 25% OOH. IH, 75% of respondents always have a radiology nurse dedicated to patient monitoring, but this reduces to 20% OOH. IH, 3% never have a radiology nurse dedicated to patient monitoring, which rises to 42% OOH. Conclusion: A significant disparity exists in the level of IR nursing support between IH and OOH. The majority of sites provide a single nurse with ad hoc additional support. This is potentially putting patients at increased risk. Radiology nurses are integral to the safe and sustainable provision of IR OOH services and a greater focus is required to ensure adequate and safe staffing levels for 24/7 IR services. - Highlights: • A significant disparity exists between the level of nursing support provided in-hours and OOH. • This applies to both the availability of a nurse to scrub and to monitor the patient. • Having a dedicated 24/7 nursing rota is mandatory to providing a deliverable OOH service.

  15. Massive radiological releases profoundly differ from controlled releases

    International Nuclear Information System (INIS)

    Pascucci-Cahen, Ludivine; Patrick, Momal

    2013-01-01

    In this article, the authors report identification and assessment of different types of costs associated with nuclear accidents. They first outline that these cost assessments must be as exhaustive or comprehensive as possible. While referring to past accidents, they define the different categories of costs: on-site costs (decontamination and dismantling, electricity not produced on the site), off-site costs (health costs, psychological costs, farming losses), image-related costs (impact on food and farm product exports, decrease of other exports), costs related to energy production, costs related to contaminated areas (refugees, lands). They give an assessment of a severe nuclear accident (i.e. an accident with important but controlled radiological releases) in France and outline that it would be a national catastrophe which could be however managed. They discuss the possible variations of the estimated costs. Then, they show that a major accident (i.e. an accident with massive radiological releases) in France would be an unmanageable European catastrophe because of the radiological consequences, of high economic costs, and of huge losses

  16. Analysis of heavy radiological accidents in NPP and gamma-irradiators

    Energy Technology Data Exchange (ETDEWEB)

    Angelov, V [Civil Defence Administration, Sofia (Bulgaria); Semova, T; Bonchev, Ts [Sofia Univ. (Bulgaria). Fizicheski Fakultet

    1996-12-31

    A review of several heavy radiological accidents, their cause, character, radioactivity emission, victims and economical impact is presented in the form of uniform tables. Eleven cases of incidents in power plants and 4 cases of accidents involving powerful gamma irradiators are considered. Radiological accidents in Bulgaria, not connected with the Kozloduy NPP, are listed. The human factor has been identified as the main cause for most of the accidents. It is stressed that the probability of heavy accident increases at the time of reactor refuelling, repair or testing. Technical failures could be eliminated by improved check and diagnostics procedures. 2 tabs., 12 refs.

  17. Analysis of heavy radiological accidents in NPP and gamma-irradiators

    International Nuclear Information System (INIS)

    Angelov, V.; Semova, T.; Bonchev, Ts.

    1995-01-01

    A review of several heavy radiological accidents, their cause, character, radioactivity emission, victims and economical impact is presented in the form of uniform tables. Eleven cases of incidents in power plants and 4 cases of accidents involving powerful gamma irradiators are considered. Radiological accidents in Bulgaria, not connected with the Kozloduy NPP, are listed. The human factor has been identified as the main cause for most of the accidents. It is stressed that the probability of heavy accident increases at the time of reactor refuelling, repair or testing. Technical failures could be eliminated by improved check and diagnostics procedures. 2 tabs., 12 refs

  18. Decision Strategy: Radiological Evaluations: Air

    Energy Technology Data Exchange (ETDEWEB)

    Sohier, A

    2000-07-01

    The objectives of SCK-CEN's R and D programme on off-site emergency management are (1) to improve methods to assess in real time the radiological impact to the population and the environment during a nuclear emergency; (2) to support and advise the Belgian authorities on specific problems concerning existing and potential hazards from exposure to ionising radiation in normal and accidental conditions; (3) to organise training courses on off-site emergency response to nuclear accidents. Main achievements in 1999 are reported on.

  19. Radiology and social media: are private practice radiology groups more social than academic radiology departments?

    Science.gov (United States)

    Glover, McKinley; Choy, Garry; Boland, Giles W; Saini, Sanjay; Prabhakar, Anand M

    2015-05-01

    This study assesses the prevalence of use of the most commonly used social media sites among private radiology groups (PRGs) and academic radiology departments (ARDs). The 50 largest PRGs and the 50 ARDs with the highest level of funding from the National Institutes of Health were assessed for presence of a radiology-specific social media account on Facebook, Twitter, Instagram, Pinterest, YouTube, and LinkedIn. Measures of organizational activity and end-user activity were collected, including the number of posts and followers, as appropriate; between-group comparisons were performed. PRGs adopted Facebook 12 months earlier (P = .02) and Twitter 18 months earlier (P = .02) than did ARDs. A total of 76% of PRGs maintained ≥1 account on the social media sites included in the study, compared with 28% of ARDs (P Instagram, 2%. The prevalence of radiology-specific social media accounts for ARDs was: Facebook, 18%; LinkedIn, 0%; Twitter, 24%; YouTube, 6%; Pinterest, 0%; and Instagram, 0%. There was no significant difference between ARDs and PRGs in measures of end-user or organizational activity on Facebook or Twitter. Use of social media in health care is emerging as mainstream, with PRGs being early adopters of Facebook and Twitter in comparison with ARDs. Competitive environments and institutional policies may be strong factors that influence how social media is used by radiologists at the group and department levels. Copyright © 2015 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  20. Radiological diagnostics in hyperparathyroidism

    International Nuclear Information System (INIS)

    Moedder, U.; Kuhn, F.P.; Gruetzner, G.

    1991-01-01

    The most important radiologically detectable effects of the primary and secondary hyperparathyroidism of the skeletal system and the periarticular soft tissue structures are presented. In the following sensitivity and specificity of radiological imaging - sonography, scintigraphy, computed tomography, magnetic resonance imaging, arteriography and selective venous sampling - in the preoperative diagnostic of the parathyroid adenomas are discussed. Therefore, radiological imaging can be omitted before primary surgery. It was only in secondary surgery that radiological process proved useful and a guide during surgical intervention. (orig.) [de

  1. Assessment of radiological protection systems among diagnostic radiology facilities in North East India.

    Science.gov (United States)

    Singh, Thokchom Dewan; Jayaraman, T; Arunkumar Sharma, B

    2017-03-01

    This study aims to assess the adequacy level of radiological protection systems available in the diagnostic radiology facilities located in three capital cities of North East (NE) India. It further attempts to understand, using a multi-disciplinary approach, how the safety codes/standards in diagnostic radiology framed by the Atomic Energy Regulatory Board (AERB) and the International Atomic Energy Agency (IAEA) to achieve adequate radiological protection in facilities, have been perceived, conceptualized, and applied accordingly in these facilities. About 30 diagnostic radiology facilities were randomly selected from three capitals of states in NE India; namely Imphal (Manipur), Shillong (Meghalaya) and Guwahati (Assam). A semi-structured questionnaire developed based on a multi-disciplinary approach was used for this study. It was observed that radiological practices undertaken in these facilities were not exactly in line with safety codes/standards in diagnostic radiology of the AERB and the IAEA. About 50% of the facilities had registered/licensed x-ray equipment with the AERB. More than 80% of the workers did not use radiation protective devices, although these devices were available in the facilities. About 85% of facilities had no institutional risk management system. About 70% of the facilities did not carry out periodic quality assurance testing of their x-ray equipment or surveys of radiation leakage around the x-ray room, and did not display radiation safety indicators in the x-ray rooms. Workers in these facilities exhibited low risk perception about the risks associated with these practices. The majority of diagnostic radiology facilities in NE India did not comply with the radiological safety codes/standards framed by the AERB and IAEA. The study found inadequate levels of radiological protection systems in the majority of facilities. This study suggests a need to establish firm measures that comply with the radiological safety codes/standards of the

  2. Pediatric radiology

    International Nuclear Information System (INIS)

    Benz-Bohm, G.

    1997-01-01

    Pediatric radiology is an important subsection of diagnostic radiology involving specific difficulties, but unfortunately is quite too often neglected as a subject of further education and training. The book therefore is not intended for specialists in the field, but for radiologists wishing to plunge deeper into the matter of pediatric radiology and to acquire a sound, basic knowledge and information about well-proven modalities, the resulting diagnostic images, and interpretation of results. The book is a compact guide and a helpful source of reference and information required for every-day work, or in special cases. With patients who are babies or children, the challenges are different. The book offers all the information needed, including important experience from pediatric hospital units that may be helpful in diagnostic evaluation, information about specific dissimilarities in anatomy and physiology which affect the imaging results, hints for radiology planning and performance, as well as information about the various techniques and their indication and achievements. The book presents a wide spectrum of informative and annotated images. (orig./CB) [de

  3. Attention for pediatric interventional radiology

    International Nuclear Information System (INIS)

    Zhu Ming; Cheng Yongde

    2005-01-01

    Radiological interventions possess wide utilization in the diagnosis and treatment for pediatric patients. Pediatric interventional radiology is an important branch of interventional radiology and also an important branch of pediatric radiology. Pediatric interventional radiology has grown substantially over the last 30 years, radiologists closely cooperation with surgeons and other physicians providing a new horizon in the management of pediatric diseases in western countries. It includes pediatric cardiac interventional radiology, pediatric neuro-interventional radiology, pediatric vascular interventional radiology, pediatric nonvascular interventional radiology, pediatric tumor interventional radiology and others. In the United States, every children hospital which owns two hundred beds has to have special trained interventional radiologists in radiologic department installing with advanced digital subtraction angiographic equipment. Interventional therapeutic procedures and diagnostic angiography have been proceeding more and more for the congenital and acquired diseases of children. The promising results give use uprising and interventional therapy as an alternative or a replacement or supplement to surgical operation. Pediatric interventional radiology is rather underdeveloped in China with a few special pediatric interventional radiologist, lack of digital subtraction angiography equipment. Pediatric radiologists have no enough field for interventional procedures such as pediatric neuro-interventional radiology and pediatric vascular interventional radiology. In the contrary adult interventional radiologists do have better interventional jobs in China and Pediatric cardiologists also share the same trend. They perform angiocardiography for congenital heart diseases and treat congenital heart disease with interventional procedures including balloon dilation of valves and vessels, coil embolization of collaterals, patent ducts and other arterial fistulae

  4. The impact of European research ethics legislation on UK radiology research activity: a bibliometric analysis

    International Nuclear Information System (INIS)

    Johnson, C.A.; Toms, A.P.

    2009-01-01

    Aim: To determine whether there is evidence of a reduction in radiology research activity in the UK following the implementation of the European research ethics legislation, which came in to force in 2001 and has been widely criticised as an impediment to research. Materials and methods: A bibliometric analysis was performed by searching PubMed for all first-author publications from UK departments of 'radiology' or 'medical imaging' between 1995 and 2007. Results were subcategorized into those papers published in the highest cited general radiology journals and by publication type: original research, reviews, and case reports. Results: From 1995 to 2007 the total number of publications rose by 6.5% from 137 to 146 with the increase occurring in non-general radiology journals. Original articles fell from 18 in 1995 to 12 in 2003, but then rose to 24 by 2007 (33% rise). This dip was paralleled by a fall and then recovery in case report publications. The most dramatic change has been in the number of review articles, which has increased more than eightfold from seven in 1995 to 65 in 2007 to become the most common form of publication. Conclusion: The overall number of original scientific articles, published by first-author UK radiologists, has increased slightly over the last 12 years despite a temporary fall associated with the introduction of new research ethics legislation.

  5. Educational activities regarding exposure reduction in interventional radiology

    International Nuclear Information System (INIS)

    Tajima, Osamu; Yabe, Hitoshi; Katoh, Kyoichi; Ueki, Junko; Nakamura, Kimiyuki; Nakatani, Akira; Wakamatsu, Osamu; Satoh, Tsugio; Nakazawa, Yasuo

    2000-01-01

    As interventional radiology (IVR) has become widespread recently, skin injury caused by exposure to radiation have been reported in academic meetings, and are a major concern in academic circles. In 1986, The Japanese Society of Circulation Imaging Technology (CITEC)'s organized a group to engage in an actual condition survey on cineangiography. We have studied exposed doses to patients in the event of cardiac catheterization using ancate data available in Japan and made efforts to spread methods of reducing exposure doses through academic meetings and medical journal. In 1998, we set up the Radiation Exposure Control Committee. The committee's objectives were to reduce exposure doses to patients and operators during cardiovascular examinations, and establish concrete of technical methods and protection guidelines for exposed dose reduction. We have studied presentations at academic meetings and study meetings, etc., and classified the results into the following 5 categories: methods of reducing radiation by X-ray equipment, methods of reducing exposure using X-ray protection devices, exposure dosimetry, clinical cases of radiation exposure, and QC, QA. The committee issued a textbook based on the reports and have educated, guided and enlightened radiological technologists, nurses and ME by holding the 'Seminar for reduction technique of radiation exposure in circulator organs.' (author)

  6. Entrepreneurship in the academic radiology environment.

    Science.gov (United States)

    Itri, Jason N; Ballard, David H; Kantartzis, Stamatis; Sullivan, Joseph C; Weisman, Jeffery A; Durand, Daniel J; Ali, Sayed; Kansagra, Akash P

    2015-01-01

    Innovation and entrepreneurship in health care can help solve the current health care crisis by creating products and services that improve quality and convenience while reducing costs. To effectively drive innovation and entrepreneurship within the current health care delivery environment, academic institutions will need to provide education, promote networking across disciplines, align incentives, and adapt institutional cultures. This article provides a general review of entrepreneurship and commercialization from the perspective of academic radiology departments, drawing on information sources in several disciplines including radiology, medicine, law, and business. Our review will discuss the role of universities in supporting academic entrepreneurship, identify drivers of entrepreneurship, detail opportunities for academic radiologists, and outline key strategies that foster greater involvement of radiologists in entrepreneurial efforts and encourage leadership to embrace and support entrepreneurship. Copyright © 2015 AUR. Published by Elsevier Inc. All rights reserved.

  7. Assessment of Natural Radioactivity and its Radiological Impact in Ortum Region in Kenya

    International Nuclear Information System (INIS)

    Wanjala, F.O.; Otwoma, D.; Kitao, T.F.; Hashim, N.O.

    2015-01-01

    The earth contains natural background radiations originating from terrestrial and cosmic sources. This study aims at assessing the levels of background radiation in air, soil and water and its associated radiological impact and also determines the elemental concentration of the rocks and soils around Ortum hills and quarry. 100 points will be measured for radioactivity in the air and 40 soil and 10 water samples will be collected for laboratory analysis using both grid and purposive sampling methods. Radioactivity in the field will be determined using the hand held Red Eye and Radiagem radiation survey meters. The levels of naturally occurring radionuclide Uranium-238 ( 238 U), Thorium-232 ( 232 Th) and Potassium-40 ( 40 K) in the soil and rocks will be determined using High Pure Germanium (HPGe) detector; the Liquid Scintillation Counter (LSC) will be used for analysis of water samples while the Energy Dispersive X-Ray Fluorescence Spectrometer (EDXRF) will be used to determine the elemental composition in the rocks and soil. The Residual Radioactivity (RESRAD) program will be used to analyze and assess the doses and risks associated with radiation exposure in Ortum region. (author)

  8. Biological Treatment of Petroleum in Radiologically Contaminated Soil

    Energy Technology Data Exchange (ETDEWEB)

    BERRY, CHRISTOPHER

    2005-11-14

    This chapter describes ex situ bioremediation of the petroleum portion of radiologically co-contaminated soils using microorganisms isolated from a waste site and innovative bioreactor technology. Microorganisms first isolated and screened in the laboratory for bioremediation of petroleum were eventually used to treat soils in a bioreactor. The bioreactor treated soils contaminated with over 20,000 mg/kg total petroleum hydrocarbon and reduced the levels to less than 100 mg/kg in 22 months. After treatment, the soils were permanently disposed as low-level radiological waste. The petroleum and radiologically contaminated soil (PRCS) bioreactor operated using bioventing to control the supply of oxygen (air) to the soil being treated. The system treated 3.67 tons of PCRS amended with weathered compost, ammonium nitrate, fertilizer, and water. In addition, a consortium of microbes (patent pending) isolated at the Savannah River National Laboratory from a petroleum-contaminated site was added to the PRCS system. During operation, degradation of petroleum waste was accounted for through monitoring of carbon dioxide levels in the system effluent. The project demonstrated that co-contaminated soils could be successfully treated through bioventing and bioaugmentation to remove petroleum contamination to levels below 100 mg/kg while protecting workers and the environment from radiological contamination.

  9. Decision-making in abnormal radiological situations

    International Nuclear Information System (INIS)

    Pretre, S.

    1998-01-01

    General problems associated with social impacts of radiology and decision making is discussed, as the main topics of the meeting. The problem of population is discussed living in areas contaminates with radioactive substances resulting from a major accident or from pest practices. This situation needs decision making process for initiating actions like relocation, resettlement or large-scale decontamination. The roles of various participants in this decision making process and in the communication with the public are considered. (R.P.)

  10. Radiological evaluation of dysphagia

    Energy Technology Data Exchange (ETDEWEB)

    Ott, D.J.; Gelfand, D.W.; Wu, W.C.; Chen, Y.M.

    1986-11-21

    Dysphagia is a common complaint in patients presenting for radiological or endoscopic examination of the esophagus and is usually due to functional or structural abnormalities of the esophageal body or esophagogastric region. The authors review the radiological evaluation of the esophagus and esophagogastric region in patients with esophageal dysphagia and discuss the roentgenographic techniques used, radiological efficacy for common structural disorders, and evaluation of esophageal motor function. Comparison is made with endoscopy in assessing dysphagia, with the conclusion that the radiological examination be used initially in patients with this complaint.

  11. Radiological evaluation of dysphagia

    International Nuclear Information System (INIS)

    Ott, D.J.; Gelfand, D.W.; Wu, W.C.; Chen, Y.M.

    1986-01-01

    Dysphagia is a common complaint in patients presenting for radiological or endoscopic examination of the esophagus and is usually due to functional or structural abnormalities of the esophageal body or esophagogastric region. The authors review the radiological evaluation of the esophagus and esophagogastric region in patients with esophageal dysphagia and discuss the roentgenographic techniques used, radiological efficacy for common structural disorders, and evaluation of esophageal motor function. Comparison is made with endoscopy in assessing dysphagia, with the conclusion that the radiological examination be used initially in patients with this complaint

  12. A project: 'Radiological protection in radiology', IAEA - Universidad Central de Venezuela

    International Nuclear Information System (INIS)

    Diaz, A.R.; Salazar, G.; Fermin, R.; Gonzalez, M.

    2001-01-01

    For several years a reference center of the UCV has been working on the project VEN/9/007 on dose reduction in diagnostic radiology sponsored by the IAEA. The dose and quality image was evaluated for different types of radiological study (conventional radiology, CT, mammography, interventional radiology) in different facilities at Caracas and others regions of the Venezuela. TL dosimeters were used to assess dose and reduction in dose. Based on the recommendations given by CEC documents on diagnostic quality criteria, a quality control program in radiological protection of patients and staff has been developed, for example: Pilot study by using TLD in personnel radiation monitoring. Comparative study between high and low kVp in chest. Evaluation and dose reduction in chest pediatric. Reduction of radiation dose in studies of billiards via Quality Image and reduction of the dose in studies of colon by enema. Radiation dose of staff in fluoroscopy procedures. Evaluation and dose reduction in dental radiography in public Institutions. A mammography accreditation program for Venezuela, applied to public hospitals. (author)

  13. Application study of RESRAD program in radiological impact assessment of very low level waste landfill

    International Nuclear Information System (INIS)

    Liu Aihua; Huang Dan; Jia Chuanzhao; Shen Haibo; Huang Kedong

    2014-01-01

    The radiological impact assessment of release utilizing a very low level waste landfill at home was carried out by using RESRAD program. The basic principles, sub-models and calculation method of RESRAD program were outlined. The selection and processing of site-specific parameters were analyzed. Selecting resident farmer scenario, the effective dose of the resident was calculated after the landfill was open, and the critical pathway as well as the critical nuclides was analyzed further. The results show that, for this landfill the maximum effective dose per year is 0.003 mSv, 0.13% of the average global public natural background radiation dose. There is small dose contribution for radioactive nuclides with short life, but large dose contribution for the nuclides with small retardation factor and middle or long-life. For the latter, the main exposure pathway is the underwater route, and enhancing indoor ventilation is an effective way to eliminate radiation dose of radon. (authors)

  14. Radiological Evaluation Standards in the Radiology Department of Shahid Beheshti Hospital (RAH) YASUJ Based on Radiology standards in 92

    OpenAIRE

    A َKalantari; SAM Khosravani

    2014-01-01

    Background & aim: Radiology personnel’s working in terms of performance and safety is one of the most important functions in order to increase the quality and quantity. This study aimed to evaluate the radiological standards in Shahid Beheshti Hospital of Yasuj, Iran, in 2013. Methods: The present cross-sectional study was based on a 118 randomly selected graphs and the ranking list, with full knowledge of the standards in radiology was performed two times. Data were analyzed using descri...

  15. Errors and malpractice lawsuits in radiology: what the radiologist needs to know.

    Science.gov (United States)

    Busardò, Francesco Paolo; Frati, Paola; Santurro, Alessandro; Zaami, Simona; Fineschi, Vittorio

    2015-09-01

    All medical specialties dealing with patients include an intrinsic risk in exposing them to issues resulting from human errors. Radiology is not spared from this risk since it includes "decision-making under conditions of uncertainty." In medical imaging, the line between the word "error" and misdiagnosis or discrepancy is very difficult to demarcate, mainly because the diagnostic process is not a binary relation and it is not always possible to establish if a pathological condition is present or not. The error in radiology is strongly related to the diagnostic process; hence, it can be defined as a "diagnostic error" which represents the most common cause of medical malpractice suits against radiologists. In this paper, the authors described the features of errors occurring in radiology, trying to establish their impact and prevalence. Secondly, some data coming from different countries were compared in order to highlight the most frequent causes leading to malpractice lawsuits in radiology and how the phenomenon of malpractice in this field is represented worldwide.

  16. Development of radiological profiles for U.S. Department of Energy low-level mixed wastes

    International Nuclear Information System (INIS)

    Wilkins, B.D.; Meshkov, N.K.; Dolak, D.A.; Wang, Y.Y.

    1995-01-01

    Radiological profiles have been developed by Argonne National Laboratory for low-level mixed wastes (LLMWs) that are under the management of the US Department of Energy (DOE). These profiles have been used in the Office of Environmental Management Programmatic Environmental Impact Statement (EM PEIS) to support the analysis of environmental and health risks associated with the various waste management strategies. The radiological characterization of DOE LLMWs is generally inadequate and has made it difficult to develop a site- and waste-stream-dependent radiological profile for LLMWs. On the basis of the operational history of the DOE sites, a simple model was developed to generate site-dependent and waste-stream-independent radiological profiles for LLMWs. This paper briefly discusses the assumptions used in this model and the uncertainties in the results

  17. Cultivation of university students in radiology using research facilities at KAERI

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Byung Chul [Nuclear Training and Education Center, Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2017-09-15

    The purpose of present research is to offer a specialized educational opportunity for potential users, university students in radiology, by developing specific curriculum on site at KAERI, using HANARO research reactor and National radiation research facilities. The specific items of this research accomplished are: First, Development and operation of various curricula for specific research using HANARO and National radiation research facilities to provide university students with opportunities to use the facilities. Second, Operation of the experiment training programs for university students in radiology to foster next generation specialists. Third, through the on-site experiment training for students in radiology, support future potential experts of the radiation research fields, and broaden the base. A textbook and a teaching aid, a questionnaire have been developed to support the program. 714 university students have completed the courses for radiology experiment from 2006 to 2017. It is hoped that these experiments broaden public awareness and acceptance by the present and potential future utilization of the research reactor and national radiation research facilities, thereby bring positive impacts to policy making.

  18. Radiological Protection Criteria for the Safety of LILW Repository in Croatia

    International Nuclear Information System (INIS)

    Levanat, I.; Lokner, V.; Subasic, D.

    2000-01-01

    Preparations for a LILW repository development in Croatia, conducted by APO Hazardous Waste Management Agency, have reached a point where the first safety assessment of the prospective facility is being attempted. For evaluation of the calculated radiological impact in the assessed option of repository development, a set of radiological protection criteria should be included in the definition of the assessment context. The Croatian regulations do not explicitly require that the repository development be supported by such safety assessment process, and do not provide a specific set of radiological criteria intended for the repository assessment which would be suitable for the constrained optimization of protection. For the initial safety assessment iterations of the prospective repository, which will address long term performance of the facility for various design and other safety options, we propose to use relatively simple radiological protection criteria, consisting only of individual dose and risk constraints for the general population. The numerical values for these constraints are established in accordance with the recognized international recommendations and in compliance with all possibly relevant Croatian safety requirements. (author)

  19. BNL ALARA center's development of a computerized Radiological Assessment and Design System (RADS)

    International Nuclear Information System (INIS)

    Dionne, B.J.; Connelly, J.M.

    1993-01-01

    The US Department of Energy's (DOE) Office of Health Physics and Industrial Hygiene sponsored a study of Radiological Engineering Programs at selected DOE contractor facilities. This study was conducted to review, evaluate, and summarize techniques and practices that should be considered in the design phase that reduce dose and the spread of radioactive materials during subsequent construction and operation at DOE radiological facilities. As in a previous study on operational ALARA programs, a variety of open-quotes good-practice documentsclose quotes will be generated. It is envisioned that these documents will serve as a resource to assist radiological engineers in the process of designing radiological facilities, and in performing radiological safety/ALARA design reviews. This paper presents the features for three good-practice documents and related software applications that are being developed based on the findings of this study. The proposed software called open-quotes Radiological Assessment and Design Systemclose quotes (RADS) will be a menu-driven database and spreadsheet program. It will be designed to provide easy, consistent, and effective implementation of the methodologies described in the three good-practice documents. These documents and the associated RADS software will provide the user with the following three functions: (1) enter dose assessment information and data into computer worksheets and provide printed tables of the results which can then be inserted into safety analysis reports or cost-benefit analysis, (2) perform a wide variety of sorts of radiological design criteria from DOE Orders and produce a checklist of the desired design criteria, and (3) enter cost/benefit data and qualitative ratings of attributes for various design alternatives which reduce dose into computer worksheets and provide printed reports of cost-effectiveness results

  20. Inpatient Complexity in Radiology-a Practical Application of the Case Mix Index Metric.

    Science.gov (United States)

    Mabotuwana, Thusitha; Hall, Christopher S; Flacke, Sebastian; Thomas, Shiby; Wald, Christoph

    2017-06-01

    With ongoing healthcare payment reforms in the USA, radiology is moving from its current state of a revenue generating department to a new reality of a cost-center. Under bundled payment methods, radiology does not get reimbursed for each and every inpatient procedure, but rather, the hospital gets reimbursed for the entire hospital stay under an applicable diagnosis-related group code. The hospital case mix index (CMI) metric, as defined by the Centers for Medicare and Medicaid Services, has a significant impact on how much hospitals get reimbursed for an inpatient stay. Oftentimes, patients with the highest disease acuity are treated in tertiary care radiology departments. Therefore, the average hospital CMI based on the entire inpatient population may not be adequate to determine department-level resource utilization, such as the number of technologists and nurses, as case length and staffing intensity gets quite high for sicker patients. In this study, we determine CMI for the overall radiology department in a tertiary care setting based on inpatients undergoing radiology procedures. Between April and September 2015, CMI for radiology was 1.93. With an average of 2.81, interventional neuroradiology had the highest CMI out of the ten radiology sections. CMI was consistently higher across seven of the radiology sections than the average hospital CMI of 1.81. Our results suggest that inpatients undergoing radiology procedures were on average more complex in this hospital setting during the time period considered. This finding is relevant for accurate calculation of labor analytics and other predictive resource utilization tools.

  1. Comparison of potential radiological impacts of 233U and 239Pu fuel cycles

    International Nuclear Information System (INIS)

    Meyer, H.R.; Little, C.A.; Witherspoon, J.P.; Till, J.E.

    1979-01-01

    Nuclear fuel cycles utilizing 233 U are currently the subject of considerable interest in the United States. This paper focuses on the identification of significant differences between the off-site radiological hazards posed by 232 Th/ 233 U (Th/U) and 238 U/ 239 Pu (U/Pu) fuel cycles, and represents a portion of our involvement in the Nonproliferation Alternative Systems Assessment Program (NASAP), to be used in support of the International Fuel Cycle Evaluation (INFCE). The major contributors to radiological dose are likely to be uranium mining and milling (58.5% of total fuel cycle dose), reprocessing (33.9%), and light-water reactor power generation (7.3%). The remainder of the cycle, including enrichment processes, fuel fabrication, transportation, and waste management, contributes only 0.3% to total estimated fuel cycle dose

  2. Radiological impact of the long-lived Chernobyl fallout isotopes in Greece

    International Nuclear Information System (INIS)

    Anagnostakis, M. J.; Petropoulos, N. P.; Hinis, E. P.; Simopoulos, S. E.

    1997-01-01

    During the period May-November 1986, 1242 soil samples of 1 cm thick surface were collected all over Greece. The samples were analyzed giving detailed mapping of the deposits of 1 37 Cs, 1 34 Cs, 1 25 Sb, 1 10 Ag, 9 5 Zr, 1 41 Ce, 1 44 Ce, 1 03 Ru, 1 06 Ru and 5 4 Mn. Mapping of the fission products 1 37 Cs, 1 34 Cs, 1 25 Sb, 1 44 Ce and 1 06 Ru allowed localisation of the three most contaminated areas in the country, near the city of Karditsa, Trikala and Naoussa. The 1 37 Cs deposits in those areas was 65 -150 kBq m - 2. The mean value all over Greece was estimated to 8-9 kBq m - 2. This deposits mapping can be used for investigation of accident radiological impact on Greek population. A computer code was developed to calculate the dose due to external irradiation and ingestion of contaminated food. The dosimetric results are reported for a number of radionuclides and exposure pathways. Committed effective dose due to ingestion over a period of 50 years of he average exposed 20 years old adult who consumed contaminated food during the firs year after the accident is estimated to about 548 μSv, and the respective value due to external irradiation was 67 μ Sv for the first year and 917 μ Sv over a period of 50 years

  3. Goiania radiological accident: five years talking with the population

    International Nuclear Information System (INIS)

    Rozental, J.J.

    1993-01-01

    This article presents an overview five years after the Goiania radiological accident. It reviews from a number of important aspects the psychological impact and conflicting opinions, the public hearings and debates and, particularly describes the victims that still have difficulties to understand the accident and its consequences. (B.C.A.). 05 refs

  4. Radiological Worker Training: Radiological Worker 2 lesson plans

    International Nuclear Information System (INIS)

    1992-10-01

    Upon completion of this g course, the participant will have the knowledge to work safely in areas controlled for a radiological purposes using proper radiological practices. The participant will be able toidentify the fundamentals of radiation, radioactive material and radioactive contamination includes identify the three basic particles of an atom, define ionization, define ionizing radiation, radioactive material and radioactive contamination, distinguish between ionizing radiation and non-ionizing radiation, define radioactivity and radioactive half-life

  5. 512-S Facility, Actinide Removal Process Radiological Design Summary Report

    International Nuclear Information System (INIS)

    Nathan, S.J.

    2004-01-01

    This report contains top-level requirements for the various areas of radiological protection for workers. Detailed quotations of the requirements for applicable regulatory documents can be found in the Radiological Design Summary Report Implementation Guide. For the purposes of demonstrating compliance with these requirements, per Engineering Standard 01064, ''shall consider / shall evaluate'' indicates that the designer must examine the requirement for the design and either incorporate or provide a technical justification as to why the requirement is not incorporated. This report describes how the Building 512-S, Actinide Removal Process meets the required radiological design criteria and requirements based on 10CFR835, DOE Order 420.1A, WSRC Manual 5Q and various other DOE guides and handbooks. The analyses supporting this Radiological Design Summary Report initially used a source term of 10.6 Ci/gallon of Cs-137 as the basis for bulk shielding calculations. As the project evolved, the source term was reduced to 1.1 Ci/gallon of Cs-137. This latter source term forms the basis for later dose rate evaluations

  6. Radiological interpretation: The 'step-child' in radiology

    International Nuclear Information System (INIS)

    Heilmann, H.P.

    1981-01-01

    Radiology has a highly developed technique, an extensive scientific literature and is excellent for acquiring information; one must contrast with this the difficulties in interpreting the information. In an attempt to find the reason for this, the process of radiological interpretation has been scrutinised. Critical consideration has been given to errors in the interpretation of the findings and to problems arising from the use of the available data. An attempt is made, with the help of diagrams, to determine a pathway for further development of information handling in X-ray diagnosis. (orig.) [de

  7. Rational use of diagnostic radiology

    International Nuclear Information System (INIS)

    Racoveanu, N.T.; Volodin, V.

    1992-01-01

    The escalating number of radiodiagnostic investigations has, as a consequence, an increase in medical irradiation of patients and of cost of radiological services. Radiologists in USA and UK have since early 1970 questioned the efficacy of various radiological investigations and produced substantial evidence that more rational approaches are necessary. WHO initiated, in 1977, a programme in this direction which has issued four technical reports which give practical recommendations on how to rationalize the use of radiological examinations. Three main directions are considered: (1) Abandonment of routine radiological examinations, as procedures with no clinical or epidemiologic significance and which represent a waste of resources and patient dose. (2) Patient selection for various radiological investigations based on clinical criteria (high, intermediate, low yield). Selected patients have an increased prevalence of the given disease and the predictive value of radiological investigation is much higher. (3) Use of diagnostic algorithms with higher cost/efficiency and risk/benefit ratios, improving the outcome of radiological examinations

  8. Assessing radiological impacts (exposures and doses) associated with the mining and milling of radioactive ores

    International Nuclear Information System (INIS)

    Williams, G.A.

    1990-01-01

    The basic units and concepts applicable to radiological assessment are presented. Data relevant to the assessment of radiological exposures from the mining and milling phases of uranium and thorium ores are discussed. As a guide to the assessment of environmental exposures to members of the public, concepts such as the critical group are defined. Environmental transport and exposure pathways are presented in general terms, together with a discussion of the use of mathematical models. The dose assessment procedures defined in the 1987 Code of Practice are described. 13 refs., 2 tabs., 1 fig

  9. Evaluation of environmental radiological impact of {sup 137} Cs repository area, site of Abadia de Goias, using the RESRAD model; Avaliacao do impacto radiologico ambiental na area do repositorio de {sup 137} Cs, em Abadia de Goias, utilizando o modelo RESRAD

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira Loureiro, C. de [Minas Gerais Univ., Belo Horizonte, MG (Brazil). Escola de Engenharia; Aquino Branco, O.E. de [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN), Belo Horizonte, MG (Brazil)

    1995-12-31

    Radiological impacts under a conservative approach were assessed for the final deposition of {sup 137} Cs at the repository site of Abadia de Goias, in the State of Goias. This site was selected as the definitive storage location for the wastes generated in the radiological accident occurred in the definitive storage location for the wastes generated in the radiological accident occurred in the nearby city of Goiania, in September of 1987. The wastes are composed of various different materials, with an estimated radioactive inventory of about 1250 Ci of {sup 137} Cs, and will be deposited definitively in a repository box of concrete with a volume of 3900 m{sup 3} approximately. A conservative approach was considered in this study and the contaminated zone was simplified as an isotropic block of soil, of 3900 m{sup 3} of volume, containing 1250 Ci of {sup 137} Cs homogeneously distributed within the whole volume. Several potential exposure scenarios were considered for the assessment of the future radiological impacts predicted at the repository site, depending on the level of institutional control maintained at the site, its future use, the time spent at the site and the sources of food. A comparative analysis of the resulting radiological impacts from all these future potential scenarios was performed using a microcomputer program named RESRAD. The simulated results indicated that the external exposure to gamma radiation, directly from the contaminated soil, is the most significant exposure pathway. The maximum predicted annual dose was below 7 mrem. (author). 5 refs, 6 figs, 3 tabs.

  10. Occupational exposure in interventional radiology

    International Nuclear Information System (INIS)

    Oh, H.J.; Lee, K.Y.; Cha, S.H.; Kang, Y.K.; Kim, H.J.; Oh, H.J.

    2003-01-01

    This study was conducted to survey of radiation safety control and to measure occupational radiation exposure dose of staff in interventional radiology in Korea. Interventioanl radiology requires the operator and assisting personnel to remain close to the patient, and thus close to primary beams of radiation. Therefore exposure doses of these personnel are significant from a radiological protection point of view. We surveyed the status of radiation safety on interventional radiology of 72 hospitals. The result were that 119 radiation equipments are using in interventional radiology and 744 staffs are composed of 307 radiologists, 116 residents of radiology, 5 general physicians, 171 radiologic technologists and 145 nurses. 81.4% and 20.2 % of operating physicians are using neck collar protector and goggle respectively. The average radiation dose was measured 0.46±0.15 mSv/10 hours fluoroscopy inside examination room in radiation protection facilities. Occupational radiation exposure data on the staff were assessed in interventional radiology procedures from 8 interventional radiology equipments of 6 university hospitals. The dose measurements were made by placing a thermoluminesent dosimeter(TLD) on various body surface of operation and assistant staff during actual interventional radiology. The measured points were the corner of the eyes, neck(on the thyroid) , wrists, chest(outside and inside of the protector), and back. Average radiation equivalent dose of the corner of left eye and left wrist of operating physicians were 1.19 mSv(0.11∼4.13 mSv)/100 minutes fluoroscopy and 4.32 mSv(0.16∼11.0 mSv)/100 minutes fluoroscopy respectively. Average exposure dose may vary depending on the type of procedure, personal skills and the quality of equipment. These results will be contributed to prepare the guide line in interventional radiology in Korea

  11. Marks in Latin-American radiology

    International Nuclear Information System (INIS)

    Souza Almeida, S. de.

    1987-01-01

    An historical retrospective of Latin-American radiology is shortly presented. Several radiologic societies as well as personalities, scientists and doctors are reported emphasizing their contribuition to radiologic Latin-American culture. (M.A.C.) [pt

  12. Use of a Machine-learning Method for Predicting Highly Cited Articles Within General Radiology Journals.

    Science.gov (United States)

    Rosenkrantz, Andrew B; Doshi, Ankur M; Ginocchio, Luke A; Aphinyanaphongs, Yindalon

    2016-12-01

    This study aimed to assess the performance of a text classification machine-learning model in predicting highly cited articles within the recent radiological literature and to identify the model's most influential article features. We downloaded from PubMed the title, abstract, and medical subject heading terms for 10,065 articles published in 25 general radiology journals in 2012 and 2013. Three machine-learning models were applied to predict the top 10% of included articles in terms of the number of citations to the article in 2014 (reflecting the 2-year time window in conventional impact factor calculations). The model having the highest area under the curve was selected to derive a list of article features (words) predicting high citation volume, which was iteratively reduced to identify the smallest possible core feature list maintaining predictive power. Overall themes were qualitatively assigned to the core features. The regularized logistic regression (Bayesian binary regression) model had highest performance, achieving an area under the curve of 0.814 in predicting articles in the top 10% of citation volume. We reduced the initial 14,083 features to 210 features that maintain predictivity. These features corresponded with topics relating to various imaging techniques (eg, diffusion-weighted magnetic resonance imaging, hyperpolarized magnetic resonance imaging, dual-energy computed tomography, computed tomography reconstruction algorithms, tomosynthesis, elastography, and computer-aided diagnosis), particular pathologies (prostate cancer; thyroid nodules; hepatic adenoma, hepatocellular carcinoma, non-alcoholic fatty liver disease), and other topics (radiation dose, electroporation, education, general oncology, gadolinium, statistics). Machine learning can be successfully applied to create specific feature-based models for predicting articles likely to achieve high influence within the radiological literature. Copyright © 2016 The Association of University

  13. Optimizing diagnostic workup in the DRG environment: Dynamic algorithms and minimizing radiologic costs may cost your hospital money

    International Nuclear Information System (INIS)

    Saint-Louis, L.A.; Henschke, C.I.; Balter, S.; Whalen, J.P.; Balter, P.

    1987-01-01

    In certain diagnosis-related group (DRG) categories, the availability of sufficient CT scanners or of new equipment, such as MR equipment, can expedite the definitive workup. This will reduce the average length of stay and hospital cost. We analyzed the total hospital and radiologic charges by DRG category for all patients admitted to our hospital in 1985 and 1986. Although the cost per procedure is relatively high, the radiologic component is a small percentage of total hospital costs (median, 3%; maximum, <10%). The authors developed alternative diagnostic algorithms for radiologic-intensive DRG categories. Different diagnostic algorithms proposed for the same clinical problems were compared analytically in terms of impact on the hospital (cost, equipment availability, and length of stay). An example is the workup for FUO. Traditional approach uses plain x-rays and gallium scans and only uses CT when localizing symptoms are present. An alternative approach is to perform CT only. Although more CT examinations would be required, there is considerable reduction in the length of hospital stay and in overall charges. Neurologic and thoracic workups will be given as examples of classes or problems that can be addressed analytically: sequencing of the workup; prevalence; patient population; resource of allocation; and introduction of new imaging modality

  14. Rational use of diagnostic radiology

    International Nuclear Information System (INIS)

    Racoveanu, N.T.; Volodin, V.

    1992-01-01

    Radiologists in USA and UK have since early 1970 questioned the efficacy of various radiological investigations and produced substantial evidence that more rational approaches are necessary. WHO initiated, in 1977, a programme which has issued four technical reports giving practical recommendations on how to rationalise the use of radiological examinations. Three main directions are considered: (1) Abandonment of routine radiological examinations, as procedures with no clinical or epidemiologic significance and which represent a waste of resources and patient dose. (2) Patient selection for various radiological investigations based on clinical criteria (high, intermediate, low yield). Selected patients have an increased prevalence of the given disease and the predictive value of radiological investigation is much higher. (3) Use of diagnostic algorithms with higher cost/efficiency and risk/benefit ratios, improving the outcome of radiological examinations. (author)

  15. Implementation of a remote system for monitoring of radiological areas of radiological areas

    International Nuclear Information System (INIS)

    Velazquez E, Walter; Galuppo G, Emiliano; Gutierrez G, Jorge; Reyes R, Jerson

    2008-01-01

    Full text: Introduction: The present work shows the development of a radiation remote monitoring system which control radiological areas in the principal facilities at CCHEN and the development in the last years to use this system called SMARR (Remote Radiological Area Monitoring System). This is an important issue in radiological safety is to know 'on line' and in a 'continuously way' the radiological variables of areas, especially if in these areas people manage radioactive sources or material, the monitoring system are operative on La Reina and Lo Aguirre Nuclear Centers. This 'knowledge' gets a good support to the radiological safety to safeguard the environment and people in the facilities. Nuclear Chilean Commission: Actually, this system is daily operating to register the background radiation and level operation, for example of the facilities research reactor, cyclone, irradiators, in order to probe the behaviors under operational requirements. The system was made using common Geiger Muller and NaI detectors. This signal is received, data by data, for a collector computer which uses a Labview program to do this displayed on a screen computer using graphics to show the activity on a radiological area, and when the lectures pass a setting value automatically the system send by e-mail and text message which also can be received for cell phones enabled for this for the supervisor. Each monitored facility is completely independent of each other and store a data backup, also every installation are monitoring with server computer, it's concentrating the information and allow to view it on line in real time, trough the intranet and internet network. In addition, the information is stored in the special report in the server and available for to do a statistics and identify the operation periods, and control of radioactive sources. The Industry: The radiological protection on industry is necessary today, the typical instrumentation on the industry is growing up in the

  16. Managing patient dose in digital radiology

    International Nuclear Information System (INIS)

    2014-01-01

    Digital techniques have the potential to improve the practice of radiology but they also risk the overuse of radiation. The main advantages of digital imaging, i.e. wide dynamic range, post processing, multiple viewing options, and electronic transfer and archiving possibilities, are clear but overexposures can occur without an adverse impact on image quality. In conventional radiography, excessive exposure produces a black film. In digital systems, good images are obtained for a large range of doses. It is very easy to obtain (and delete) images with digital fluoroscopy systems, and there may be a tendency to obtain more images than necessary. In digital radiology, higher patient dose usually means improved image quality, so a tendency to use higher patient doses than necessary could occur. Different medical imaging tasks require different levels of image quality, and doses that have no additional benefit for the clinical purpose should be avoided. Image quality can be compromised by inappropriate levels of data compression and/or post processing techniques. All these new challenges should be part of the optimisation process and should be included in clinical and technical protocols. Local diagnostic reference levels should be re-evaluated for digital imaging, and patient dose parameters should be displayed at the operator console. Frequent patient dose audits should occur when digital techniques are introduced. Training in the management of image quality and patient dose in digital radiology is necessary. Digital radiology will involve new regulations and invoke new challenges for practitioners. As digital images are easier to obtain and transmit, the justification criteria should be reinforced. Commissioning of digital systems should involve clinical specialists, medical physicists, and radiographers to ensure that imaging capability and radiation dose management are integrated. Quality control requires new procedures and protocols (visualisation, transmission

  17. Methodology for evaluating radiological consequences of the management of very low-level solide waste arising from decommissioning of nuclear power plants

    International Nuclear Information System (INIS)

    Smith, G.M.; Hemming, C.R.; Clark, J.M.; Chapuis, A.M.; Garbay, H.

    1985-01-01

    In this report a methodology is described, and illustrated by examples, for the evaluation of individual doses and collective dose commitments arising as a result of various management modes for very low-level solid wastes arising from the decommissioning of nuclear power plants. Estimates have been made of the masses of materials activated and contaminated to within three concentration limits, 0.37, 3.7 and 37 Bq g-1, at three times after reactor shutdown, 5 y, 25 y and 100 y. The disposal options considered are shallow land burial, at a municipal landfill site or at the reactor site, and disposal on the seabed in coastal waters or the deep ocean. It is assumed that there is no special treatment to reduce or eliminate the potential radiological hazard. Consideration has also been given to the radiological impact of recycling of contaminated steel. The radiological impacts of all the management options for the wastes considered were found to be small. It may therefore be acceptable to allow such very low-level wastes to be disposal of without special restrictions provided that the level and type of activity of the wastes can be verified. In addition the health detriment cost associated with all the management options is small, so it is likely that other factors such as transport and engineering costs will be more important in final decisions about the management of these wastes

  18. Ergonomics in radiology

    Energy Technology Data Exchange (ETDEWEB)

    Goyal, N. [Department of Radiology, University Hospital of Wales, Cardiff (United Kingdom)], E-mail: nimitgoyal@doctors.org.uk; Jain, N.; Rachapalli, V. [Department of Radiology, University Hospital of Wales, Cardiff (United Kingdom)

    2009-02-15

    The use of computers is increasing in every field of medicine, especially radiology. Filmless radiology departments, speech recognition software, electronic request forms and teleradiology are some of the recent developments that have substantially increased the amount of time a radiologist spends in front of a computer monitor. Computers are also needed for searching literature on the internet, communicating via e-mails, and preparing for lectures and presentations. It is well known that regular computer users can suffer musculoskeletal injuries due to repetitive stress. The role of ergonomics in radiology is to ensure that working conditions are optimized in order to avoid injury and fatigue. Adequate workplace ergonomics can go a long way in increasing productivity, efficiency, and job satisfaction. We review the current literature pertaining to the role of ergonomics in modern-day radiology especially with the development of picture archiving and communication systems (PACS) workstations.

  19. Ergonomics in radiology

    International Nuclear Information System (INIS)

    Goyal, N.; Jain, N.; Rachapalli, V.

    2009-01-01

    The use of computers is increasing in every field of medicine, especially radiology. Filmless radiology departments, speech recognition software, electronic request forms and teleradiology are some of the recent developments that have substantially increased the amount of time a radiologist spends in front of a computer monitor. Computers are also needed for searching literature on the internet, communicating via e-mails, and preparing for lectures and presentations. It is well known that regular computer users can suffer musculoskeletal injuries due to repetitive stress. The role of ergonomics in radiology is to ensure that working conditions are optimized in order to avoid injury and fatigue. Adequate workplace ergonomics can go a long way in increasing productivity, efficiency, and job satisfaction. We review the current literature pertaining to the role of ergonomics in modern-day radiology especially with the development of picture archiving and communication systems (PACS) workstations

  20. How Secure Is Your Radiology Department? Mapping Digital Radiology Adoption and Security Worldwide.

    Science.gov (United States)

    Stites, Mark; Pianykh, Oleg S

    2016-04-01

    Despite the long history of digital radiology, one of its most critical aspects--information security--still remains extremely underdeveloped and poorly standardized. To study the current state of radiology security, we explored the worldwide security of medical image archives. Using the DICOM data-transmitting standard, we implemented a highly parallel application to scan the entire World Wide Web of networked computers and devices, locating open and unprotected radiology servers. We used only legal and radiology-compliant tools. Our security-probing application initiated a standard DICOM handshake to remote computer or device addresses, and then assessed their security posture on the basis of handshake replies. The scan discovered a total of 2774 unprotected radiology or DICOM servers worldwide. Of those, 719 were fully open to patient data communications. Geolocation was used to analyze and rank our findings according to country utilization. As a result, we built maps and world ranking of clinical security, suggesting that even the most radiology-advanced countries have hospitals with serious security gaps. Despite more than two decades of active development and implementation, our radiology data still remains insecure. The results provided should be applied to raise awareness and begin an earnest dialogue toward elimination of the problem. The application we designed and the novel scanning approach we developed can be used to identify security breaches and to eliminate them before they are compromised.

  1. Radiological protection of patients

    International Nuclear Information System (INIS)

    Niroomand-Rad, A.

    2003-01-01

    The benefits of ionizing radiation in the diagnosis and treatment of cancer, as well as other conditions such as cardiac ablation, are well established. However determination, monitoring, and evaluation of patient doses is not as easy task. Furthermore, radiation doses for individual patients may vary greatly from one radiological procedure to another. Attention is needed to reduce unnecessary radiation exposure to patients from All types of radiation producing machines and equipment. The patient risk from radiation injury-stochastic and/or deterministic must be weighted against the benefits of a proper medical examination or treatment as well as the risk of depriving the patient from the necessary medical care. Arbitrary reduction of radiological patient doses without regard to final outcome is determined to proper medical care provided to the patient. Sacrificing image quality in order to reduce patient dose is potentially harmful to the patient as well. Furthermore, the role of radiation exposure incurred from screening procedures such as mammography, needs to be properly considered and differentiated from medically indicated procedures. A known radiation induced risk needs to be balanced against diagnostic efficacy of a screening procedure. In these cases, regulations on standards and guidelines for determination, monitoring, and evaluation of patient doses may be appropriate. In this paper, the technical data collected in the United States have been compared with the corresponding data in Canada. However, even here, it has been recognized that we can not assume that one dose limit fits all. It is advisable to consider individual patient specifics if it means the difference between detection and miss

  2. Improved understanding of human anatomy through self-guided radiological anatomy modules.

    Science.gov (United States)

    Phillips, Andrew W; Smith, Sandy G; Ross, Callum F; Straus, Christopher M

    2012-07-01

    To quantifiably measure the impact of self-instructed radiological anatomy modules on anatomy comprehension, demonstrated by radiology, gross, and written exams. Study guides for independent use that emphasized structural relationships were created for use with two online radiology atlases. A guide was created for each module of the first year medical anatomy course and incorporated as an optional course component. A total of 93 of 96 eligible students participated. All exams were normalized to control for variances in exam difficulty and body region tested. An independent t-test was used to compare overall exam scores with respect to guide completion or incompletion. To account for aptitude differences between students, a paired t-test of each student's exam scores with and without completion of the associated guide was performed, thus allowing students to serve as their own controls. Twenty-one students completed no study guides; 22 completed all six guides; and 50 students completed between one and five guides. Aggregate comparisons of all students' exam scores showed significantly improved mean performance when guides were used (radiology, 57.8% [percentile] vs. 45.1%, P < .001; gross, 56.9% vs. 46.5%, P = .001; written, 57.8% vs. 50.2%, P = .011). Paired comparisons among students who completed between one and five guides demonstrated significantly higher mean practical exam scores when guides were used (radiology, 49.3% [percentile] vs. 36.0%, P = .001; gross, 51.5% vs. 40.4%, P = .005), but not higher written scores. Radiological anatomy study guides significantly improved anatomy comprehension on radiology, gross, and written exams. Copyright © 2012 AUR. Published by Elsevier Inc. All rights reserved.

  3. Socio/economic/ecological impacts of nuclear power plants

    International Nuclear Information System (INIS)

    Golden, J.; Watson, J.

    1975-01-01

    A nuclear facility has both radiological and non-radiological effects on the environment. To minimize radiological effects, limits are set on releases of radioactive materials that will cause either direct or indirect exposure (such as the food chain). Exposure pathways for man and other organisms are described with comparisons of typical calculated doses and design objective doses. Non-radiological impacts of nuclear plants are classified as ecological-physical and socio/economic considerations, which include eighteen areas affected during each phase of the nuclear facility cycle. The ecological-physical environment is impacted in the areas of hydrology, terrestrial and aquatic ecology, and air and water quality. The socio-economic environment is impacted in areas of land use, tax base, employment, economic stimulus, relocation, lifestyle, demand for service, aesthetics, and power needs. Case studies of large construction projects are described in the appendix

  4. Geographic origin of publications in radiological journals as a function of GDP and percentage of GDP spent on research.

    LENUS (Irish Health Repository)

    Halpenny, Darragh

    2010-06-01

    The aim of this study was to examine the geographic origin of publications in the highest impacting radiology journals and to examine the link between the percentage of gross domestic product (GDP) spent on research by a country and the output of radiology publications.

  5. Evaluation guideline for the study of the radiological impact of based nuclear installations (INB) presented in support of releases authorization demands; Guide d'examen pour l'etude de l'impact radiologique d'une installation nucleaire de base (INB) fournie a l'appui des demandes d'autorisation de rejets

    Energy Technology Data Exchange (ETDEWEB)

    Chartier, M; Despres, A; Supervil, S; Conte, D; Hubert, P; Oudiz, A; Champion, D

    2002-10-01

    In the case of a license demand for the effluents release and water taking for a nuclear installation, the operating must realize a study of the nuclear effluents radiological impact on the environment and the public health. In this context, the study presents technical and methodological specifications which led the Direction of the Nuclear Installations Safety (DSIN) and the General Direction of the Health (DGS) to ask the IPSN the elaboration of a guideline to help these studies evaluation. The guideline presents the regulatory context, the description of the installations, the treatment and the control processes, the rules of management, the description of the environment, the estimation of the radiological impacts and the environment control system definition. (A.L.B.)

  6. Experienced in Conducting Radiological Impact Assessment (RIA) in Oil and Gas Industry

    International Nuclear Information System (INIS)

    Khairuddin Mohamad Kontol; Ismail Sulaiman; Azmi Hassan; Faizal Azrin Abdul Razalim

    2011-01-01

    Oil and gas industry is a major contributor to the nation economy. Oil sludge and scales produced during production contain enhanced naturally occurring radioactive material (NORM).All the oil sludge and scales are temporarily stored at the crude oil terminal premise. Sludge and scales are under the jurisdiction of Department of Environment (DOE) and Atomic Energy Licensing Board (AELB).AELB has issued a guideline regarding the disposal of sludge and scales as in (LEM/TEK/30, 1996). In this guideline, Radiological Impact Assessment (RIA) should be carried out on all proposed disposals and demonstrate that no member of public will be exposed to more than 1 mSv/y. Malaysian Nuclear Agency (Nuclear Malaysia) has the expertise and capability to conduct the RIA. Nuclear Malaysia has been conducting RIA for local and international oil and gas companies operated in Malaysia. Recently, AELB has issued code of practice on radiation protection for oil and gas industry (LEM/TEK/58, 2009). In this code of practice, RIA shall be conducted to assess the dose received by a critical group of public as a result of the disposal of oil sludge and scale higher than 3 Bq/g Total Activity Concentration (TAC). For exemption by AELB, the RIA calculated dose shall not exceed 0.3 mSv/y. (author)

  7. Warming Early Mars by Impact Degassing of Reduced Greenhouse Gases

    Science.gov (United States)

    Haberle, R. M.; Zahnle, K.; Barlow, N. G.

    2018-01-01

    Reducing greenhouse gases are once again the latest trend in finding solutions to the early Mars climate dilemma. In its current form collision induced absorptions (CIA) involving H2 and/or CH4 provide enough extra greenhouse power in a predominately CO2 atmosphere to raise global mean surface temperatures to the melting point of water provided the atmosphere is thick enough and the reduced gases are abundant enough. Surface pressures must be at least 500 mb and H2 and/or CH4 concentrations must be at or above the several percent level for CIA to be effective. Atmospheres with 1-2 bars of CO2 and 2- 10% H2 can sustain surface environments favorable for liquid water. Smaller concentrations of H2 are sufficient if CH4 is also present. If thick CO2 atmospheres with percent level concentrations of reduced gases are the solution to the faint young Sun paradox for Mars, then plausible mechanisms must be found to generate and sustain the gases. Possible sources of reducing gases include volcanic outgassing, serpentinization, and impact delivery; sinks include photolyis, oxidation, and escape to space. The viability of the reduced greenhouse hypothesis depends, therefore, on the strength of these sources and sinks. In this paper we focus on impact delivered reduced gases.

  8. A national UK survey of radiology trainees special interest choices: what and why?

    Science.gov (United States)

    Parvizi, Nassim; Bhuva, Shaheel

    2017-11-01

    A national survey was designed to better understand factors influencing special interest choices, future aspirations of UK radiology trainees and perceptions of breast radiology. A SurveyMonkey questionnaire was developed and distributed to all radiology trainees in the UK through the British Institute of Radiology, RCR Junior Radiologists Forum and by directly contacting UK training schemes as well as by social media between December 2015 and January 2016. From 21 training schemes across the UK, 232 responses were received. Over half entered radiology after foundation training and 62% were ST1-3; one-fifth of trainees intended to leave the NHS. The most popular special interests were musculoskeletal (18%), abdominal imaging (16%) and neuroradiology (13%). Gynaecological and oncological imaging proved to be the least popular. Strong personal interest, a successful rotation during training, a mix of imaging modalities, direct impact on patient care and job prospects were the most popular factors influencing career choice. Research and potential for private income were the least influential factors. Respondents detailed their perceptions of breast radiology, selecting an awareness of career prospects (41%) and a better trainee experience (36%) as factors that would increase their interest in pursuing it as a career. Understanding the factors that influence special interest choice is essential to addressing the alarming staffing shortfalls that will befall certain radiology special interests. Addressing trainee's preconceptions and improving the trainee experience are key to attracting trainees to breast radiology. Advances in knowledge: This is the first survey of its kind in the UK literature designed to evaluate special interest career choices and the factors that influence those among radiology trainees.

  9. Ecological risk assessment of mixtures of radiological and chemical stressors: Methodology to implement an msPAF approach

    International Nuclear Information System (INIS)

    Beaumelle, Léa; Della Vedova, Claire; Beaugelin-Seiller, Karine; Garnier-Laplace, Jacqueline; Gilbin, Rodolphe

    2017-01-01

    A main challenge in ecological risk assessment is to account for the impact of multiple stressors. Nuclear facilities can release both radiological and chemical stressors in the environment. This study is the first to apply species sensitivity distribution (SSD) combined with mixture models (concentration addition (CA) and independent action (IA)) to derive an integrated proxy of the ecological impact of combined radiological and chemical stressors: msPAF (multisubstance potentially affected fraction of species). The approach was tested on the routine liquid effluents from nuclear power plants that contain both radioactive and stable chemicals. The SSD of ionising radiation was significantly flatter than the SSD of 8 stable chemicals (namely Cr, Cu, Ni, Pb, Zn, B, chlorides and sulphates). This difference in shape had strong implications for the selection of the appropriate mixture model: contrarily to the general expectations the IA model gave more conservative (higher msPAF) results than the CA model. The msPAF approach was further used to rank the relative potential impact of radiological versus chemical stressors. - Highlights: • msPAF methodology was applied on mixtures of radiological and chemical stressors. • A consistent set of chronic SSDs was collected for ionising radiation and 8 stable chemicals. • The SSD of ionising radiation had lower steepness than the SSD of stable chemicals. • This resulted in higher msPAF values based on the IA than on the CA mixture model. - The msPAF approach combining SSD and mixture models was used for the first time on mixtures of radiological and chemical stressors.

  10. Schatzki ring in children and young adults: clinical and radiologic findings

    Energy Technology Data Exchange (ETDEWEB)

    Buckley, K.; Buonomo, C. [Department of Radiology, Children`s Hospital, Boston, MA (United States); Husain, K.; Nurko, S. [Division of Gastroenterology, Children`s Hospital, Boston, MA (United States)

    1998-11-01

    Background. The Schatzki ring is a well-known clinical and radiologic entity in adults, but is thought to be rare in childhood. Objective. To review the clinical presentations and radiologic findings of children and young adults with Schatzki rings. Materials and methods. A retrospective review of all barium swallow examinations done between 1990 and 1996 revealed 20 patients with Schatzki rings. Results. The most frequent presenting symptoms of these patients were progressive dysphagia with solid food and acute food impaction. Radiographic findings of Schatzki rings were typical in all cases. Twelve patients had endoscopy and all had evidence of esophagitis. Conclusion. Schatzki rings are not rare in childhood. The patients are symptomatic, presenting with either progressive dysphagia with solids or acute food impaction. A thorough evaluation of the distal esophagus should be performed in patients with a suggestive clinical history. (orig.) With 2 figs., 8 refs.

  11. Fixatives Used for Decommissioning and Maintenance of Radiological Facilities – 17537

    Energy Technology Data Exchange (ETDEWEB)

    Demmer, Rick; Fox, Don; Reese, Stephen; Banford, Anthony; Dodds, Jonathan

    2017-01-01

    The Idaho National Laboratory (INL) and the United Kingdom (UK) National Nuclear Laboratory (NNL) have been collaborating for several years on materials and methods for the fogged/misted introduction of fixatives into radiologically contaminated facilities. The objective of the project is to deliver a process for reducing airborne radiological and/or mercury contamination and affixing loose contamination in place, thereby reducing contamination risk to employees and decreasing D&D cost and schedule. The developed process provides a reliable, unmanned method of introducing a coating that captures and fixes contamination in place within facilities. The INL coating, termed FX2, has undergone extensive non-radiological testing, including determination that it is non-flammable, affixes contamination and flows well through unusual geometries (testing at Florida International University). A series of non-active fogging trials for activity knock/tie-down application have been completed at NNL Workington on behalf of Idaho National Laboratory (INL). These trials performed by the NNL employed commercially available agricultural fogging equipment and the INL’s knock/tie-down latex formulation (FX-2). This testing successfully demonstrated the ability of the fogging devices to successfully spray the FX-2 formulation within various scenarios, and prepared the project for a radioactive trial. The INL has also developed a mercury vapor reducing form of the coating termed FX-Hg, which has shown great promise in laboratory studies.

  12. Extended outlook: description, utilization, and daily applications of cloud technology in radiology.

    Science.gov (United States)

    Gerard, Perry; Kapadia, Neil; Chang, Patricia T; Acharya, Jay; Seiler, Michael; Lefkovitz, Zvi

    2013-12-01

    The purpose of this article is to discuss the concept of cloud technology, its role in medical applications and radiology, the role of the radiologist in using and accessing these vast resources of information, and privacy concerns and HIPAA compliance strategies. Cloud computing is the delivery of shared resources, software, and information to computers and other devices as a metered service. This technology has a promising role in the sharing of patient medical information and appears to be particularly suited for application in radiology, given the field's inherent need for storage and access to large amounts of data. The radiology cloud has significant strengths, such as providing centralized storage and access, reducing unnecessary repeat radiologic studies, and potentially allowing radiologic second opinions more easily. There are significant cost advantages to cloud computing because of a decreased need for infrastructure and equipment by the institution. Private clouds may be used to ensure secure storage of data and compliance with HIPAA. In choosing a cloud service, there are important aspects, such as disaster recovery plans, uptime, and security audits, that must be considered. Given that the field of radiology has become almost exclusively digital in recent years, the future of secure storage and easy access to imaging studies lies within cloud computing technology.

  13. Informatics in radiology: radiology gamuts ontology: differential diagnosis for the Semantic Web.

    Science.gov (United States)

    Budovec, Joseph J; Lam, Cesar A; Kahn, Charles E

    2014-01-01

    The Semantic Web is an effort to add semantics, or "meaning," to empower automated searching and processing of Web-based information. The overarching goal of the Semantic Web is to enable users to more easily find, share, and combine information. Critical to this vision are knowledge models called ontologies, which define a set of concepts and formalize the relations between them. Ontologies have been developed to manage and exploit the large and rapidly growing volume of information in biomedical domains. In diagnostic radiology, lists of differential diagnoses of imaging observations, called gamuts, provide an important source of knowledge. The Radiology Gamuts Ontology (RGO) is a formal knowledge model of differential diagnoses in radiology that includes 1674 differential diagnoses, 19,017 terms, and 52,976 links between terms. Its knowledge is used to provide an interactive, freely available online reference of radiology gamuts ( www.gamuts.net ). A Web service allows its content to be discovered and consumed by other information systems. The RGO integrates radiologic knowledge with other biomedical ontologies as part of the Semantic Web. © RSNA, 2014.

  14. Radiology and the internet, basic principles and technical requirements

    International Nuclear Information System (INIS)

    Boegl, K.

    2000-01-01

    As a new communication media the Internet has revolutionized the global exchange of information which is one of the major sources of progress in medicine. This article reviews the history of the Internet's evolution and describes some fundamental technical concepts. The importance of Internet services for everyday professional work is examined with special consideration of radiology. Special emphasis is laid on the current technical limitations that have delayed a broad practical implementation of tele-medical applications. As a highly innovative medical speciality, radiology has always been at the forefront of research and development in the field of clinical Internet applications. By taking a look at recent innovations, the impact of the Internet on the radiologist's working environment of the future is highlighted. (orig.) [de

  15. Preliminary radiological assessments of low-level waste repositories

    International Nuclear Information System (INIS)

    Nancarrow, D.J.; Sumerling, T.J.; Ashton, J.

    1988-06-01

    Preliminary assessments of the post-closure radiological impact from the disposal of low-level radioactive wastes in shallow engineered facilities at four sites are presented. This provides a framework to practice and refine a methodology that could be used, on behalf of the Department, for independent assessment of any similar proposal from Nirex. Information and methodological improvements that would be required are identified. (author)

  16. Annual evaluation of routine radiological survey/monitoring frequencies for the High Ranking Facilities Deactivating Project at Oak Ridge, Tennessee

    International Nuclear Information System (INIS)

    1998-12-01

    The Bethel Valley Watershed at the Oak Ridge National Laboratory (ORNL) has several Environmental Management (EM) facilities that are designated for deactivation and subsequent decontamination and decommissioning (D and D). The Surplus Facilities Program at ORNL provides surveillance and maintenance support for these facilities as deactivation objectives are completed to reduce the risks associated with radioactive material inventories, etc. The Bechtel Jacobs Company LLC Radiological Control (RADCON) Program has established requirements for radiological monitoring and surveying radiological conditions in these facilities. These requirements include an annual evaluation of routine radiation survey and monitoring frequencies. Radiological survey/monitoring frequencies were evaluated for two High Ranking Facilities Deactivation Project facilities, the Bulk Shielding Facility and Tower Shielding Facility. Considerable progress has been made toward accomplishing deactivation objectives, thus the routine radiological survey/monitoring frequencies are being reduced for 1999. This report identifies the survey/monitoring frequency adjustments and provides justification that the applicable RADCON Program requirements are also satisfied

  17. Mobile technology in radiology resident education.

    Science.gov (United States)

    Korbage, Aiham C; Bedi, Harprit S

    2012-06-01

    The authors hypothesized that ownership of a mobile electronic device would result in more time spent learning radiology. Current trends in radiology residents' studying habits, their use of electronic and printed radiology learning resources, and how much of the funds allotted to them are being used toward printed vs electronic education tools were assessed in this study. A survey study was conducted among radiology residents across the United States from June 13 to July 5, 2011. Program directors listed in the Association of Program Directors in Radiology e-mail list server received an e-mail asking for residents to participate in an online survey. The questionnaire consisted of 12 questions and assessed the type of institution, the levels of training of the respondents, and book funds allocated to residents. It also assessed the residents' study habits, access to portable devices, and use of printed and electronic radiology resources. Radiology residents are adopters of new technologies, with 74% owning smart phones and 37% owning tablet devices. Respondents spend nearly an equal amount of time learning radiology from printed textbooks as they do from electronic resources. Eighty-one percent of respondents believe that they would spend more time learning radiology if provided with tablet devices. There is considerable use of online and electronic resources and mobile devices among the current generation of radiology residents. Benefits, such as more study time, may be obtained by radiology programs that incorporate tablet devices into the education of their residents. Copyright © 2012 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  18. Radiological conditions at Bikini Atoll: Prospects for resettlement

    International Nuclear Information System (INIS)

    1998-01-01

    An international Advisory Group met at IAEA Headquarters in Vienna on 11-15 December 1995 for the purpose of reviewing the current radiological conditions at Bikini Atoll, Republic of the Marshall Islands, and advising on the prospects for rehabilitation of the atoll and resettlement of its indigenous population. The Advisory Group was convened by the IAEA in response to a request for technical assistance from the Government of the Marshall Islands within the framework of IAEA technical co-operation project MHL/9/003, 'Radiological Monitoring in Bikini Atoll'. The primary aim of this review was to assist the Bikinian people to form their own judgement on the radiological conditions at their atoll and on the prospects for resettling there, should they so desire. At the meeting, the Advisory Group benefited greatly from the participation of a delegation from the Marshall Islands. At the request of the Government of the Marshall Islands, the international review was limited to Bikini Atoll and did not extend to other atolls, islands and isles affected by radioactive fallout from the testing. Moreover, within Bikini Atoll, it was concentrated on Bikini Island, where the Bikinian population formerly resided. The review relates to the prevailing radiological circumstances and their implications for the future habitability of the atoll. It is not intended to include the retrospective assessment of the past radiological impact of nuclear testing. The United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR) has routinely estimated, and reported to the United Nations General Assembly, radiation levels and effects attributable to nuclear weapon testing, including the tests carried out in the territory of the Marshall Islands. Some of the UNSCEAR estimates have been included in the report, but only for the sake of completeness

  19. Comparison of the distribution of non-radiological and radiological fatal risk in Ontario industries (addendum)

    International Nuclear Information System (INIS)

    Davis, C.K.; Forbes, W.F.; Hayward, L.M.

    1986-09-01

    Occupational limits for exposure to ionizing radiation, in force in Canada, are based on recommendations of international bodies, particularly the International Commission on Radiological Protection (ICRP). To determine whether the ICRP assertions concerning the similarity of the distributions of occupational risk at the higher risk levels (from non-radiation and from radiation work) to Canada a study of the high end of the distributions of non-radiological risk of occupational fatalities in the province of Ontario was performed. For the present study total doses from exposure to sources of ionizing radiation for Ontario workers were converted to relative risk rates to allow direct comparison with the non-radiological results. In addition, absolute values for the radiological risk rates (RRR) were derived. The radiological risk estimates are based on workers who work both from nuclear reactions and from X-rays. The conclusion is made that the radiological and non-radiological risk rate (NRRR) distributions are similar in shape, but the RRR are approximately 1 to 27 percent of the NRRR, depending on the industry concerned

  20. Radiological assessment and optimization

    International Nuclear Information System (INIS)

    Zeevaert, T.; Sohier, A.

    1998-01-01

    The objectives of SCK-CEN's research in the field of radiological assessment and optimization are (1) to implement ALARA principles in activities with radiological consequences; (2) to develop methodologies for radiological optimization in decision-aiding; (3) to improve methods to assess in real time the radiological hazards in the environment in case of an accident; (4) to develop methods and programmes to assist decision-makers during a nuclear emergency; (5) to support the policy of radioactive waste management authorities in the field of radiation protection; (6) to investigate computer codes in the area of multi criteria analysis; (7) to organise courses on off-site emergency response to nuclear accidents. Main achievements in these areas for 1997 are summarised

  1. Cost analysis in interventional radiology-A tool to optimize management costs

    International Nuclear Information System (INIS)

    Clevert, D.-A.; Stickel, M.; Jung, E.M.; Reiser, M.; Rupp, N.

    2007-01-01

    Objective: The objective of the study was to analyze the methods to reduce cost in interventional radiology departments by reorganizing procurement. Materials and methods: All products used in Department of Interventional Radiology were inventoried. An ABC-analysis was completed and A-products (high-value and high turnover products) underwent a XYZ-analysis which predicted demand on the basis of ordering frequency. Then criteria for a procurement strategy for the different material categories were fixed. The net working capital (NWC) was calculated using an interest rate of 8%/year. Results: Total annual material turnover was 353,000 Euro . The value of all A-products determined by the inventory was 260,000 Euro . Changes in the A-product procurement strategy tapped a cost reduction potential of 14,500/year Euro . The resulting total saving was 17,200 Euro . Improved stores management added another 37,500 Euro. The total cost cut of 52,000 Euro is equivalent to 14.7% of annual expenses. Conclusion: A flexible procurement strategy helps to reduce the storage and capital tie-up costs of A-products in interventional radiology without affecting the quality of service provided to patients

  2. Radiology. 3. rev. and enl. ed.

    International Nuclear Information System (INIS)

    Reiser, Maximilian; Kuhn, Fritz-Peter; Debus, Juergen

    2011-01-01

    The text book on radiology covers the following issues: Part A: General radiology: Fundamental physics: radiation biology; radiation protection fundamentals: radiologic methods; radiotherapy; nuclear medicine. Part B: Special radiology: Thorax; heart; urogenital tract and retroperitoneum; vascular system and interventional radiology; esophagus, stomach, small and large intestines; liver, biliary system, pancreas and spleen; mammary glands; central nervous system; spinal cord and spinal canal; basis of the skull, facial bones and eye socket; neck; pediatric imaging diagnostics.

  3. Effects of reduced-impact logging on fish assemblages in central Amazonia.

    Science.gov (United States)

    Dias, Murilo S; Magnusson, William E; Zuanon, Jansen

    2010-02-01

    In Amazonia reduced-impact logging, which is meant to reduce environmental disturbance by controlling stem-fall directions and minimizing construction of access roads, has been applied to large areas containing thousands of streams. We investigated the effects of reduced-impact logging on environmental variables and the composition of fish in forest streams in a commercial logging concession in central Amazonia, Amazonas State, Brazil. To evaluate short-term effects, we sampled 11 streams before and after logging in one harvest area. We evaluated medium-term effects by comparing streams in 11 harvest areas logged 1-8 years before the study with control streams in adjacent areas. Each sampling unit was a 50-m stream section. The tetras Pyrrhulina brevis and Hemigrammus cf. pretoensis had higher abundances in plots logged > or =3 years before compared with plots logged fish composition did not differ two months before and immediately after reduced-impact logging. Temperature and pH varied before and after logging, but those differences were compatible with normal seasonal variation. In the medium term, temperature and cover of logs were lower in logged plots. Differences in ordination scores on the basis of relative fish abundance between streams in control and logged areas changed with time since logging, mainly because some common species increased in abundance after logging. There was no evidence of species loss from the logging concession, but differences in log cover and ordination scores derived from relative abundance of fish species persisted even after 8 years. For Amazonian streams, reduced-impact logging appears to be a viable alternative to clear-cut practices, which severely affect aquatic communities. Nevertheless, detailed studies are necessary to evaluated subtle long-term effects.

  4. Radiological Worker Training: Radiological Worker 1 lesson plans

    International Nuclear Information System (INIS)

    1992-10-01

    Upon completion of this training course, the participant will have the knowledge to work safely in areas controlled for radiological purposes using proper radiological practices. Upon completion of this unit the participant will be able to identify the fundamentals of radiation, radioactive material and radioactive contamination. The participant will be able to select the correct response from a group of responses which verifies his/her ability to: Define ionizing radiation, radioactive material and radioactive contamination and identify the units used to measure radiation and radioactivity

  5. Evaluation of radiological impacts for environmental radioactivity distribution in the Kartini reactor area

    International Nuclear Information System (INIS)

    Yazid, M.; Suratman; Sutresna, G.; Aminjoyo, S.

    1996-01-01

    This evaluation covered of gross radioactivity. K-40 radioactivity in the water, soil and grass samples. The measurement of Cs-137 and Sr-90 radioactivity in the water samples have also been done. The aim of this research was determined of radiological impacts in the environment around the Kartini reactor. The water, soil and plant samples were counted of gross beta, Sr-90 activity by beta counter and for K-40, Cs-137 activity by low background gamma spectrometer. For this evaluation can be concluded there are no indication of the radioactivity release from the Kartini reactor operation. Gross beta radioactivity in the water, soil and grass sample are between 0.06-0.61 Bq/l, 0.24-0.79 Bq/g and 3.47-5.70 Bq/g ash. Radioactivity of K-40 in the water, soil and grass sample are between 0.09-0.56 Bq/l, 0.12-0.59 Bq/g and 0.29-0.93 Bq/g ash. The radioactivity of Cs-137 in the water samples are between under limit detectable level to 88.62 mBq/l and Sr-90 are between under limit detectable level to 24.22 mBq/l. (author)

  6. Adoption of an integrated radiology reading room within a urologic oncology clinic: initial experience in facilitating clinician consultations.

    Science.gov (United States)

    Rosenkrantz, Andrew B; Lepor, Herbert; Taneja, Samir S; Recht, Michael P

    2014-05-01

    The authors describe their initial experience in implementing an integrated radiology reading room within a urologic oncology clinic, including the frequency and nature of clinician consultations and the perceived impact on patient management by clinicians. A radiology reading room was established within an office-based urologic oncology clinic in proximity to the surgeon's work area. A radiologist was present in this reading room for a 3-hour shift each day. The frequency and nature of consultations during these shifts were recorded. Also, the clinic's staff completed a survey assessing perceptions of the impact of the integrated reading room on patient management. One hundred two consultations occurred during 57 included dates (average, 1.8 consultations per shift): 52% for review of external cases brought in by patients on discs, 43% for review of internal cases, and 5% for direct review by the radiologist of imaging with patients. The maximum number of consultations during a single shift was 8. All of the clinic's urologists indicated that >90% of consultations benefited patient care. The clinicians indicated tendencies to view consultations as affecting management in the majority of cases, to be more likely to seek consultation for outside imaging when the radiologist was on site, and to be less likely to repeat outside imaging when the radiologist was on site. The integrated reading room within the clinic has potential to improve the quality of care, for instance by facilitating increased review of outside imaging studies and thereby potentially reducing duplicate ordering and by enabling occasional direct image review with patients by radiologists. Copyright © 2014 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  7. 21 CFR 892.1980 - Radiologic table.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Radiologic table. 892.1980 Section 892.1980 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1980 Radiologic table. (a) Identification. A radiologic...

  8. Radiology integration in a multi-hospital system.

    Science.gov (United States)

    Welch, D

    1999-01-01

    In 1989, Salt Lake City's Intermountain Health Care (IHC) began a process to reduce costs and streamline processes. Divided into four geographic regions, IHC consists of 24 hospitals and 100 clinics, a 400-member practitioner-physician group, and a staff of 23,000. IHC determined that three Salt Lake Valley hospitals, part of its Urban Central Region, must become one entity with shared management and a reduced staff to cover operations at all three hospitals. Management of the three radiology departments were charged with creating an integration process for the three hospitals. Two directors were selected to manage radiology and meet the outlined goals. Difficulty arose when one director needed to make changes in a facility managed by the other. The directors found that structuring by modality allowed them to plan for all three facilities, standardize equipment purchases and create integrated rather than departmental programs. As consolidation was taking place in top management, employees worried what the resulting changes meant for their jobs. Many were unfamiliar with the concepts of team structure and continuous quality improvement. Various courses and meetings were held to educate staff members and bring them up to new standards. Most successful were the meetings that allowed staff from different facilities to come together and share ideas. Although travel was an issue, these meetings quickly helped move the integration processes forward as peer relationships were developed. Employees were recruited for cross-training and new staff worked wherever needed. As they began to share data, the three hospitals identified best-practice and internal benchmarks. IHC is now ready to hire a single director to manage the radiology departments at the three Salt Lake Valley hospitals.

  9. Canadian Association of Radiologists White Paper on Artificial Intelligence in Radiology.

    Science.gov (United States)

    Tang, An; Tam, Roger; Cadrin-Chênevert, Alexandre; Guest, Will; Chong, Jaron; Barfett, Joseph; Chepelev, Leonid; Cairns, Robyn; Mitchell, J Ross; Cicero, Mark D; Poudrette, Manuel Gaudreau; Jaremko, Jacob L; Reinhold, Caroline; Gallix, Benoit; Gray, Bruce; Geis, Raym

    2018-05-01

    Artificial intelligence (AI) is rapidly moving from an experimental phase to an implementation phase in many fields, including medicine. The combination of improved availability of large datasets, increasing computing power, and advances in learning algorithms has created major performance breakthroughs in the development of AI applications. In the last 5 years, AI techniques known as deep learning have delivered rapidly improving performance in image recognition, caption generation, and speech recognition. Radiology, in particular, is a prime candidate for early adoption of these techniques. It is anticipated that the implementation of AI in radiology over the next decade will significantly improve the quality, value, and depth of radiology's contribution to patient care and population health, and will revolutionize radiologists' workflows. The Canadian Association of Radiologists (CAR) is the national voice of radiology committed to promoting the highest standards in patient-centered imaging, lifelong learning, and research. The CAR has created an AI working group with the mandate to discuss and deliberate on practice, policy, and patient care issues related to the introduction and implementation of AI in imaging. This white paper provides recommendations for the CAR derived from deliberations between members of the AI working group. This white paper on AI in radiology will inform CAR members and policymakers on key terminology, educational needs of members, research and development, partnerships, potential clinical applications, implementation, structure and governance, role of radiologists, and potential impact of AI on radiology in Canada. Copyright © 2018 The Authors. Published by Elsevier Inc. All rights reserved.

  10. Reduced-impact sliding pressure control valve for pneumatic hammer drill

    Science.gov (United States)

    Polsky, Yarom [Oak Ridge, TN; Grubelich, Mark C [Albuquerque, NM; Vaughn, Mark R [Albuquerque, NM

    2012-05-15

    A method and means of minimizing the effect of elastic valve recoil in impact applications, such as percussive drilling, where sliding spool valves used inside the percussive device are subject to poor positioning control due to elastic recoil effects experienced when the valve impacts a stroke limiting surface. The improved valve design reduces the reflected velocity of the valve by using either an energy damping material, or a valve assembly with internal damping built-in, to dissipate the compression stress wave produced during impact.

  11. Advanced Research Workshop on Preparedness for Nuclear and Radiological Threats

    CERN Document Server

    Diamond, David; Nuclear Threats and Security Challenges

    2015-01-01

    With the dissolution of the Soviet Union the nuclear threats facing the world are constantly evolving and have grown more complex since the end of the Cold War. The diversion of complete weapon systems or nuclear material to rogue nations and terrorist organizations has increased. The events of the past years have proved the necessity to reevaluate these threats on a level never before considered.  In recognition that no single country possesses all of the answers to the critical scientific, institutional and legal questions associated with combating nuclear and radiological terrorism, the NATO Advanced Research Workshop on “Preparedness for Nuclear and Radiological Threats” and this proceeding was structured to promote wide-ranging, multi-national exploration of critical technology needs and underlying scientific challenges to reducing the threat of nuclear/radiological terrorism; to illustrate through country-specific presentations how resulting technologies were used in national programs; and to outli...

  12. Evaluation of the contribution of radiological imaging to the final diagnosis in medical case reports

    International Nuclear Information System (INIS)

    Wiesinger, Isabel; Scharf, Gregor; Platz, Natascha; Dendl, Lena M.; Stroszczynski, Christian; Schreyer, Andreas G.; Pawlik, Michael T.

    2015-01-01

    To evaluate the clinical value and impact of radiological imaging in published medial case reports. We analysed 671 consecutively published case reports of a peer-reviewed medical journal for case reports. The general use of radiological imaging as well as the specific imaging modality used in each case (ultrasound, x-ray, fluoroscopy, CT, MRI) was documented, and most importantly the 'final problem solver', i.e. the diagnostic modality giving the final clue to the patient's diagnosis, was identified. In 511 of 671 (76.1 %) analysed case reports at least one radiological modality was used in the diagnostic cascade. In 28.6 % of all cases the final diagnosis was achieved by radiological imaging. All other cases were solved by the patient's history and physical examination (15.2 %), histology (12.4 %), and blood analysis (9.6 %). When radiology was the 'final problem solver', it was mainly CT (51.6 %) and MRI (30.6 %). In 52.2 % of the case reports the radiological image was included in the article. In case reports published in a prominent general medical journal radiological imaging is an important key player in the diagnostic process. In many cases, it is also the diagnostic tool which ultimately leads to determining the final diagnosis. (orig.)

  13. Evaluation of the contribution of radiological imaging to the final diagnosis in medical case reports

    Energy Technology Data Exchange (ETDEWEB)

    Wiesinger, Isabel; Scharf, Gregor; Platz, Natascha; Dendl, Lena M.; Stroszczynski, Christian; Schreyer, Andreas G. [University Hospital Regensburg, Institute of Radiology, Regensburg (Germany); Pawlik, Michael T. [Intensive Care and Emergency Medicine, Institute of Anaesthesiology, Regensburg (Germany)

    2015-05-01

    To evaluate the clinical value and impact of radiological imaging in published medial case reports. We analysed 671 consecutively published case reports of a peer-reviewed medical journal for case reports. The general use of radiological imaging as well as the specific imaging modality used in each case (ultrasound, x-ray, fluoroscopy, CT, MRI) was documented, and most importantly the 'final problem solver', i.e. the diagnostic modality giving the final clue to the patient's diagnosis, was identified. In 511 of 671 (76.1 %) analysed case reports at least one radiological modality was used in the diagnostic cascade. In 28.6 % of all cases the final diagnosis was achieved by radiological imaging. All other cases were solved by the patient's history and physical examination (15.2 %), histology (12.4 %), and blood analysis (9.6 %). When radiology was the 'final problem solver', it was mainly CT (51.6 %) and MRI (30.6 %). In 52.2 % of the case reports the radiological image was included in the article. In case reports published in a prominent general medical journal radiological imaging is an important key player in the diagnostic process. In many cases, it is also the diagnostic tool which ultimately leads to determining the final diagnosis. (orig.)

  14. Comparative analysis of dose levels to patients in radiological procedures guided by fluoroscopy

    International Nuclear Information System (INIS)

    Gomez, Pablo Luis; Fernandez, Manuel; Ramos, Julio A.; Delgado, Jose Miguel; Cons, Nestor

    2013-01-01

    This work presents the comparative data of the dose indicators for patient in radiological processes with respect to the values published in the ICRP document. It is analyzed the need for different strategies to communicate to different specialists mechanisms to optimize the radiation beginning with practice by training of second degree level in radiological protection and then, working with them the basics of equipment management to reduce doses without detriment to the welfare purpose

  15. Radiological hazards

    International Nuclear Information System (INIS)

    Hamilton, M.

    1984-01-01

    The work of the (United Kingdom) National Radiological Protection Board is discussed. The following topics are mentioned: relative contributions to genetically significant doses of radiation from various sources; radon gas in non-coal mines and in dwelling houses; effects of radiation accidents; radioactive waste disposal; radiological protection of the patient in medicine; microwaves, infrared radiation and cataracts; guidance notes for use with forthcoming Ionising Radiations Regulations; training courses; personal dosimetry service; work related to European Communities. (U.K.)

  16. Health surveillance of radiological work

    International Nuclear Information System (INIS)

    Pauw, H.; Vliet, J.V.D.; Zuidema, H.

    1988-01-01

    Shielding x-ray devices and issuing film badges to radiological workers in 1936 can be considered the start of radiological protection in the Philips enterprises in the Netherlands. Shielding and equipment were constantly improved based upon the dosimetry results of the filmbadges. The problem of radioactive waste led to the foundation of a central Philips committee for radiological protection in 1956, which in 1960 also issued an internal license system in order to regulate the proper precautions to be taken : workplace design and layout, technological provisions and working procedures. An evaluation of all radiological work in 1971 learnt that a stricter health surveillance program was needed to follow up the precautions issued by the license. On one hand a health surveillance program was established and on the other hand all types of radiological work were classified. In this way an obligatory and optimal health surveillance program was issued for each type of radiological work

  17. The radiological impact of actinides discharged to the Irish Sea

    International Nuclear Information System (INIS)

    Hunt, G.J.; Smith, B.D.

    1999-01-01

    This paper describes the radiological effects of releases of actinides to the Irish Sea from Sellafield, the major source. Exposure pathways to man since the commencement of discharges in 1952 are reviewed; the importance of actinides began to increase with increased discharges in the 1970s. With the demise of the porphyra/laverbread pathway due to transport difficulties, the pathway due to fish and shellfish consumption became critical, particularly for actinides through molluscan shellfish. A reassessment on the current basis of effective dose shows that peak exposures to the critical group of about 2 mSv yr -1 were received in the mid-1970s, about 30% of which was due to actinides. Effective doses have since reduced but the relative importance of actinides is greater, due to the interplay of discharges of radionuclides from Sellafield and their behaviour in the environment. Additive doses through sea food due to releases of natural radionuclides from the Marchon phosphate plant at Whitehaven are also considered, although the actinide component from this source has been small. Exposures due to actinides from Sellafield via other pathways are shown to be much lower than those involving sea food. Collective doses are also considered; these peaked at about 300 man-Sv to the European population (including the UK) in 1979, with only a few percent due to actinides. As in the case of critical group doses, the relative importance of actinides has increased in recent years within the decreasing total collective dose. For both critical group and collective doses, therefore, the actinide component needs to be kept under review. (Copyright (c) 1999 Elsevier Science B.V., Amsterdam. All rights reserved.)

  18. An overview of dental radiology: a primer on dental radiology

    International Nuclear Information System (INIS)

    Manny, E.F.; Carlson, K.C.; McClean, P.M.; Rachlin, J.A.; Segal, P.

    1980-01-01

    To provide medical and scientific background on certain selected technologies generally considered to be of particular significance, the National Center for Health Care Technology (NCHCT) has commissioned a series of overview papers. This is one of several projects entered into jointly by the Bureau of Radiological Health (BRH) and NCHCT relating to the use of radiation for health care. Dental radiation protection has been a long-time interest of BRH. Both past and on-going efforts to minimize population radiation exposure from electronic products have included specific action programs directed at minimizing unnecessary radiation exposure to the population from dental radiology. Current efforts in quality assurance and referral criteria are two aspects of NCHCT's own assessment of this technology which are described within the larger picture presented in this overview. The issues considered in this document go beyond the radiation exposure aspects of dental x-ray procedures. To be responsive to the informational needs of NCHCT, the assessment includes various other factors that influence the practice of dental radiology. It is hoped this analysis will serve as the basis for planning and conducting future programs to improve the practice of dental radiology

  19. Radiology's value chain.

    Science.gov (United States)

    Enzmann, Dieter R

    2012-04-01

    A diagnostic radiology value chain is constructed to define its main components, all of which are vulnerable to change, because digitization has caused disaggregation of the chain. Some components afford opportunities to improve productivity, some add value, while some face outsourcing to lower labor cost and to information technology substitutes, raising commoditization risks. Digital image information, because it can be competitive at smaller economies of scale, allows faster, differential rates of technological innovation of components, initiating a centralization-to-decentralization technology trend. Digitization, having triggered disaggregation of radiology's professional service model, may soon usher in an information business model. This means moving from a mind-set of "reading images" to an orientation of creating and organizing information for greater accuracy, faster speed, and lower cost in medical decision making. Information businesses view value chain investments differently than do small professional services. In the former model, producing a better business product will extend image interpretation beyond a radiologist's personal fund of knowledge to encompass expanding external imaging databases. A follow-on expansion with integration of image and molecular information into a report will offer new value in medical decision making. Improved interpretation plus new integration will enrich and diversify radiology's key service products, the report and consultation. A more robust, information-rich report derived from a "systems" and "computational" radiology approach will be facilitated by a transition from a professional service to an information business. Under health care reform, radiology will transition its emphasis from volume to greater value. Radiology's future brightens with the adoption of a philosophy of offering information rather than "reads" for decision making. Staunchly defending the status quo via turf wars is unlikely to constitute a

  20. Evaluation of the radiological impact in the aquatic system in the surrounding of IPEN-CNEN/SP

    International Nuclear Information System (INIS)

    Jacomino, V.M.F.; Gordon, A.M.P.L.; Venturini, L.

    1989-12-01

    In order to control the discharges of radioactive material in the aquatic system (Jaguare stream and Pinheiros river) in the vicinity of IPEN-CNEN/SP an effluent monitoring program was established on a routine basis. This control is carried out by measuring the activity of the radionuclides present in the liquid effluents (source term) using gamma spectrometry and/or spectrophotometry. The results obtained are then compared with the discharge limits adopted by CNEN when a decision is made upon the discharge of the effluent under consideration. In 1988 the total activity discharged by the nuclear installations available was 1997, 9x10 6 Bq in a total volume of 2421,4 m 3 . The next step was to evaluate the effective equivalent dose in the general public by using the results of the source term and the information available concerning the environment. It was assumed that the only critical pathway is the external gamma irradiation of the people that work in the nearby of the discharge points in Pinheiros river. The effective equivalent dose obtained was 39,4η Sv and the most relevant radionuclides that should be considered 60 Co, 137 Cs, 131 I and 226 Ra. This result is less than 1/10 of the maximum admissible dose limit adopted by the Radiological Protection Standards which is 10 -3 Sv/year. In order to measure the level of radioactivity in the environment, samples of ground water, water and sediments of Pinheiros river were collected and analyzed by using gamma spectrometry and fluorimetry. The radionuclides found were 226 Ra, 22228 Ra, U Nat, 40 K and 7 Be with activities corresponding to the background levels. The analysis of these results and the evaluation of the equivalent dose show that the radiological impact in the aquatic systems considered is insignificant. (author) [pt