WorldWideScience

Sample records for realistic arteries subjected

  1. Numerical analysis of blood flow in realistic arteries subjected to strong non-uniform magnetic fields

    International Nuclear Information System (INIS)

    Kenjeres, Sasa

    2008-01-01

    The paper reports on a comprehensive mathematical model for simulations of blood flow under the presence of strong non-uniform magnetic fields. The model consists of a set of Navier-Stokes equations accounting for the Lorentz and magnetisation forces, and a simplified set of Maxwell's equations (Biot-Savart/Ampere's law) for treating the imposed magnetic fields. The relevant hydrodynamic and electromagnetic properties of human blood were taken from the literature. The model is then validated for different test cases ranging from a simple cylindrical geometry to real-life right-coronary arteries in humans. The time-dependency of the wall-shear-stress for different stenosis growth rates and the effects of the imposed strong non-uniform magnetic fields on the blood flow pattern are presented and analysed. It is concluded that an imposed non-uniform magnetic field can create significant changes in the secondary flow patterns, thus making it possible to use this technique for optimisations of targeted drug delivery

  2. Maximizing direct current power delivery from bistable vibration energy harvesting beams subjected to realistic base excitations

    Science.gov (United States)

    Dai, Quanqi; Harne, Ryan L.

    2017-04-01

    Effective development of vibration energy harvesters is required to convert ambient kinetic energy into useful electrical energy as power supply for sensors, for example in structural health monitoring applications. Energy harvesting structures exhibiting bistable nonlinearities have previously been shown to generate large alternating current (AC) power when excited so as to undergo snap-through responses between stable equilibria. Yet, most microelectronics in sensors require rectified voltages and hence direct current (DC) power. While researchers have studied DC power generation from bistable energy harvesters subjected to harmonic excitations, there remain important questions as to the promise of such harvester platforms when the excitations are more realistic and include both harmonic and random components. To close this knowledge gap, this research computationally and experimentally studies the DC power delivery from bistable energy harvesters subjected to such realistic excitation combinations as those found in practice. Based on the results, it is found that the ability for bistable energy harvesters to generate peak DC power is significantly reduced by introducing sufficient amount of stochastic excitations into an otherwise harmonic input. On the other hand, the elimination of a low amplitude, coexistent response regime by way of the additive noise promotes power delivery if the device was not originally excited to snap-through. The outcomes of this research indicate the necessity for comprehensive studies about the sensitivities of DC power generation from bistable energy harvester to practical excitation scenarios prior to their optimal deployment in applications.

  3. Population of 224 realistic human subject-based computational breast phantoms

    Energy Technology Data Exchange (ETDEWEB)

    Erickson, David W. [Carl E. Ravin Advanced Imaging Laboratories, Duke University Medical Center, Durham, North Carolina 27705 and Medical Physics Graduate Program, Duke University, Durham, North Carolina 27705 (United States); Wells, Jered R., E-mail: jered.wells@duke.edu [Clinical Imaging Physics Group and Carl E. Ravin Advanced Imaging Laboratories, Duke University Medical Center, Durham, North Carolina 27705 and Medical Physics Graduate Program, Duke University, Durham, North Carolina 27705 (United States); Sturgeon, Gregory M. [Carl E. Ravin Advanced Imaging Laboratories, Duke University Medical Center, Durham, North Carolina 27705 (United States); Samei, Ehsan [Department of Radiology and Carl E. Ravin Advanced Imaging Laboratories, Duke University Medical Center, Durham, North Carolina 27705 and Departments of Physics, Electrical and Computer Engineering, and Biomedical Engineering, and Medical Physics Graduate Program, Duke University, Durham, North Carolina 27705 (United States); Dobbins, James T. [Department of Radiology and Carl E. Ravin Advanced Imaging Laboratories, Duke University Medical Center, Durham, North Carolina 27705 and Departments of Physics and Biomedical Engineering and Medical Physics Graduate Program, Duke University, Durham, North Carolina 27705 (United States); Segars, W. Paul [Department of Radiology and Carl E. Ravin Advanced Imaging Laboratories, Duke University Medical Center, Durham, North Carolina 27705 and Medical Physics Graduate Program, Duke University, Durham, North Carolina 27705 (United States); Lo, Joseph Y. [Department of Radiology and Carl E. Ravin Advanced Imaging Laboratories, Duke University Medical Center, Durham, North Carolina 27705 and Departments of Electrical and Computer Engineering and Biomedical Engineering and Medical Physics Graduate Program, Duke University, Durham, North Carolina 27705 (United States)

    2016-01-15

    Purpose: To create a database of highly realistic and anatomically variable 3D virtual breast phantoms based on dedicated breast computed tomography (bCT) data. Methods: A tissue classification and segmentation algorithm was used to create realistic and detailed 3D computational breast phantoms based on 230 + dedicated bCT datasets from normal human subjects. The breast volume was identified using a coarse three-class fuzzy C-means segmentation algorithm which accounted for and removed motion blur at the breast periphery. Noise in the bCT data was reduced through application of a postreconstruction 3D bilateral filter. A 3D adipose nonuniformity (bias field) correction was then applied followed by glandular segmentation using a 3D bias-corrected fuzzy C-means algorithm. Multiple tissue classes were defined including skin, adipose, and several fractional glandular densities. Following segmentation, a skin mask was produced which preserved the interdigitated skin, adipose, and glandular boundaries of the skin interior. Finally, surface modeling was used to produce digital phantoms with methods complementary to the XCAT suite of digital human phantoms. Results: After rejecting some datasets due to artifacts, 224 virtual breast phantoms were created which emulate the complex breast parenchyma of actual human subjects. The volume breast density (with skin) ranged from 5.5% to 66.3% with a mean value of 25.3% ± 13.2%. Breast volumes ranged from 25.0 to 2099.6 ml with a mean value of 716.3 ± 386.5 ml. Three breast phantoms were selected for imaging with digital compression (using finite element modeling) and simple ray-tracing, and the results show promise in their potential to produce realistic simulated mammograms. Conclusions: This work provides a new population of 224 breast phantoms based on in vivo bCT data for imaging research. Compared to previous studies based on only a few prototype cases, this dataset provides a rich source of new cases spanning a wide range

  4. Development of realistic physical breast phantoms matched to virtual breast phantoms based on human subject data

    International Nuclear Information System (INIS)

    Kiarashi, Nooshin; Nolte, Adam C.; Sturgeon, Gregory M.; Ghate, Sujata V.; Segars, William P.; Nolte, Loren W.; Samei, Ehsan

    2015-01-01

    Purpose: Physical phantoms are essential for the development, optimization, and evaluation of x-ray breast imaging systems. Recognizing the major effect of anatomy on image quality and clinical performance, such phantoms should ideally reflect the three-dimensional structure of the human breast. Currently, there is no commercially available three-dimensional physical breast phantom that is anthropomorphic. The authors present the development of a new suite of physical breast phantoms based on human data. Methods: The phantoms were designed to match the extended cardiac-torso virtual breast phantoms that were based on dedicated breast computed tomography images of human subjects. The phantoms were fabricated by high-resolution multimaterial additive manufacturing (3D printing) technology. The glandular equivalency of the photopolymer materials was measured relative to breast tissue-equivalent plastic materials. Based on the current state-of-the-art in the technology and available materials, two variations were fabricated. The first was a dual-material phantom, the Doublet. Fibroglandular tissue and skin were represented by the most radiographically dense material available; adipose tissue was represented by the least radiographically dense material. The second variation, the Singlet, was fabricated with a single material to represent fibroglandular tissue and skin. It was subsequently filled with adipose-equivalent materials including oil, beeswax, and permanent urethane-based polymer. Simulated microcalcification clusters were further included in the phantoms via crushed eggshells. The phantoms were imaged and characterized visually and quantitatively. Results: The mammographic projections and tomosynthesis reconstructed images of the fabricated phantoms yielded realistic breast background. The mammograms of the phantoms demonstrated close correlation with simulated mammographic projection images of the corresponding virtual phantoms. Furthermore, power

  5. Development of realistic physical breast phantoms matched to virtual breast phantoms based on human subject data

    Energy Technology Data Exchange (ETDEWEB)

    Kiarashi, Nooshin [Carl E. Ravin Advanced Imaging Laboratories, Department of Radiology, Duke University Medical Center, Durham, North Carolina 27710 and Department of Electrical and Computer Engineering, Duke University, Durham, North Carolina 27708 (United States); Nolte, Adam C. [Carl E. Ravin Advanced Imaging Laboratories, Department of Radiology, Duke University Medical Center, Durham, North Carolina 27710 and Department of Biomedical Engineering, Duke University, Durham, North Carolina 27708 (United States); Sturgeon, Gregory M.; Ghate, Sujata V. [Carl E. Ravin Advanced Imaging Laboratories, Department of Radiology, Duke University Medical Center, Durham, North Carolina 27710 (United States); Segars, William P. [Carl E. Ravin Advanced Imaging Laboratories, Department of Radiology, Duke University Medical Center, Durham, North Carolina 27710 and Medical Physics Graduate Program, Duke University, Durham, North Carolina 27708 (United States); Nolte, Loren W. [Department of Electrical and Computer Engineering, Duke University, Durham, North Carolina 27708 and Department of Biomedical Engineering, Duke University, Durham, North Carolina 27708 (United States); Samei, Ehsan [Carl E. Ravin Advanced Imaging Laboratories, Department of Radiology, Duke University Medical Center, Durham, North Carolina 27710 (United States); Department of Electrical and Computer Engineering, Duke University, Durham, North Carolina 27708 (United States); Department of Biomedical Engineering, Duke University, Durham, North Carolina 27708 (United States); Medical Physics Graduate Program, Duke University, Durham, North Carolina 27708 (United States); Department of Physics, Duke University, Durham, North Carolina 27708 (United States); and others

    2015-07-15

    Purpose: Physical phantoms are essential for the development, optimization, and evaluation of x-ray breast imaging systems. Recognizing the major effect of anatomy on image quality and clinical performance, such phantoms should ideally reflect the three-dimensional structure of the human breast. Currently, there is no commercially available three-dimensional physical breast phantom that is anthropomorphic. The authors present the development of a new suite of physical breast phantoms based on human data. Methods: The phantoms were designed to match the extended cardiac-torso virtual breast phantoms that were based on dedicated breast computed tomography images of human subjects. The phantoms were fabricated by high-resolution multimaterial additive manufacturing (3D printing) technology. The glandular equivalency of the photopolymer materials was measured relative to breast tissue-equivalent plastic materials. Based on the current state-of-the-art in the technology and available materials, two variations were fabricated. The first was a dual-material phantom, the Doublet. Fibroglandular tissue and skin were represented by the most radiographically dense material available; adipose tissue was represented by the least radiographically dense material. The second variation, the Singlet, was fabricated with a single material to represent fibroglandular tissue and skin. It was subsequently filled with adipose-equivalent materials including oil, beeswax, and permanent urethane-based polymer. Simulated microcalcification clusters were further included in the phantoms via crushed eggshells. The phantoms were imaged and characterized visually and quantitatively. Results: The mammographic projections and tomosynthesis reconstructed images of the fabricated phantoms yielded realistic breast background. The mammograms of the phantoms demonstrated close correlation with simulated mammographic projection images of the corresponding virtual phantoms. Furthermore, power

  6. Influence of stenosis on hemodynamic parameters in the realistic left coronary artery under hyperemic conditions.

    Science.gov (United States)

    Kamangar, Sarfaraz; Badruddin, Irfan Anjum; Badarudin, A; Nik-Ghazali, N; Govindaraju, Kalimuthu; Salman Ahmed, N J; Yunus Khan, T M

    2017-03-01

    The current study investigates the hyperemic flow effects on heamodynamics parameters such as velocity, wall shear stress in 3D coronary artery models with and without stenosis. The hyperemic flow is used to evaluate the functional significance of stenosis in the current era. Patients CT scan data of having healthy and coronary artery disease was chosen for the reconstruction of 3D coronary artery models. The diseased 3D models of coronary artery shows a narrowing of >50% lumen area. Computational fluid dynamics was performed to simulate the hyperemic flow condition. The results showed that the recirculation zone was observed immediate to the stenosis and highest wall shear stress was observed across the stenosis. The decrease in pressure was found downstream to the stenosis as compared to the coronary artery without stenosis. Our analysis provides an insight into the distribution of wall shear stress and pressure drop, thus improving our understanding of hyperemic flow effect under both conditions.

  7. Numerical analysis of blood flow in realistic arteries subjected to strong non-uniform magnetic fields

    NARCIS (Netherlands)

    Kenjeres, S.

    2008-01-01

    The paper reports on a comprehensive mathematical model for simulations of blood flow under the presence of strong non-uniform magnetic fields. The model consists of a set of Navier–Stokes equations accounting for the Lorentz and magnetisation forces, and a simplified set of Maxwell’s equations

  8. Intra-arterial infusion of prostaglandin E1 in normal subjects and patients with peripheral arterial disease

    DEFF Research Database (Denmark)

    Nielsen, P E; Nielsen, S L; Holstein, P

    1976-01-01

    Acute vasodilatation was produced by infusion of prostaglandin E1 (PGE1) in the femoral artery in 6 patients with occlusive arterial disease of the legs and in 3 normal subjects. The effect on blood flow and on blood pressure was measured at different segments of the leg with the strain gauge...

  9. Sex differences in cardiovascular and subjective stress reactions: prospective evidence in a realistic military setting.

    Science.gov (United States)

    Taylor, Marcus K; Larson, Gerald E; Hiller Lauby, Melissa D; Padilla, Genieleah A; Wilson, Ingrid E; Schmied, Emily A; Highfill-McRoy, Robyn M; Morgan, Charles A

    2014-01-01

    Evidence points to heightened physiological arousal in response to acute stress exposure as both a prospective indicator and a core characteristic of posttraumatic stress disorder (PTSD). Because females may be at higher risk for PTSD development, it is important to evaluate sex differences in acute stress reactions. This study characterized sex differences in cardiovascular and subjective stress reactions among military survival trainees. One hundred and eighty-five military members (78% males) were studied before, during, and 24 h after stressful mock captivity. Cardiovascular (heart rate [HR], systolic blood pressure [SBP], diastolic blood pressure [DBP]) and dissociative states were measured at all three time points. Psychological impact of mock captivity was assessed during recovery. General linear modeling with repeated measures evaluated sex differences for each cardiovascular endpoint, and causal steps modeling was used to explore interrelationships among sex, cardiovascular reactions and psychological impact of mock captivity. Although females had lower SBP than males at all three time points, the difference was most pronounced at baseline and during stress. Accordingly, females showed greater residual elevation in SBP during recovery. Females had lower DBP at all three time points. In addition, females reported greater psychological impact of mock captivity than males. Exploratory causal steps modeling suggested that stress-induced HR may partially mediate the effect of sex on psychological impact of mock captivity. In conclusion, this study demonstrated sex-specific cardiovascular stress reactions in military personnel, along with greater psychological impact of stress exposure in females. This research may elucidate sex differences in PTSD development.

  10. Prevalence of renal artery stenosis in subjects with moderate hypertension. A population-based study

    DEFF Research Database (Denmark)

    Andersen, Ulrik B; Borglykke, Anders; Jørgensen, Torben

    2011-01-01

    Abstract Aim. To examine the prevalence of significant renal artery stenosis (RAS) in subjects with moderate to severe hypertension. Materials and methods. Subjects aged 50-66 years with blood pressure >160/100 mmHg or receiving antihypertensive treatment were selected from the population study...

  11. Cocoa intake and arterial stiffness in subjects with cardiovascular risk factors

    Directory of Open Access Journals (Sweden)

    Recio-Rodríguez José

    2012-02-01

    Full Text Available Abstract Background To analyze the relationship of cocoa intake to central and peripheral blood pressure, arterial stiffness, and carotid intima-media thickness in subjects with some cardiovascular risk factor. Findings Design: A cross-sectional study of 351 subjects (mean age 54.76 years, 62.4% males. Measurements: Intake of cocoa and other foods using a food frequency questionnaire, central and peripheral (ambulatory and office blood pressure, central and peripheral augmentation index, pulse wave velocity, ambulatory arterial stiffness index, carotid intima-media thickness, and ankle-brachial index. Results: Higher pulse wave velocity and greater cardiovascular risk were found in non-cocoa consumers as compared to high consumers (p Conclusions In subjects with some cardiovascular risk factors, cocoa consumption does not imply improvement in the arterial stiffness values. Trial Registration Clinical Trials.gov Identifier: NCT01325064.

  12. Strength training reduces arterial blood pressure but not sympathetic neural activity in young normotensive subjects

    Science.gov (United States)

    Carter, Jason R.; Ray, Chester A.; Downs, Emily M.; Cooke, William H.

    2003-01-01

    The effects of resistance training on arterial blood pressure and muscle sympathetic nerve activity (MSNA) at rest have not been established. Although endurance training is commonly recommended to lower arterial blood pressure, it is not known whether similar adaptations occur with resistance training. Therefore, we tested the hypothesis that whole body resistance training reduces arterial blood pressure at rest, with concomitant reductions in MSNA. Twelve young [21 +/- 0.3 (SE) yr] subjects underwent a program of whole body resistance training 3 days/wk for 8 wk. Resting arterial blood pressure (n = 12; automated sphygmomanometer) and MSNA (n = 8; peroneal nerve microneurography) were measured during a 5-min period of supine rest before and after exercise training. Thirteen additional young (21 +/- 0.8 yr) subjects served as controls. Resistance training significantly increased one-repetition maximum values in all trained muscle groups (P < 0.001), and it significantly decreased systolic (130 +/- 3 to 121 +/- 2 mmHg; P = 0.01), diastolic (69 +/- 3 to 61 +/- 2 mmHg; P = 0.04), and mean (89 +/- 2 to 81 +/- 2 mmHg; P = 0.01) arterial blood pressures at rest. Resistance training did not affect MSNA or heart rate. Arterial blood pressures and MSNA were unchanged, but heart rate increased after 8 wk of relative inactivity for subjects in the control group (61 +/- 2 to 67 +/- 3 beats/min; P = 0.01). These results indicate that whole body resistance exercise training might decrease the risk for development of cardiovascular disease by lowering arterial blood pressure but that reductions of pressure are not coupled to resistance exercise-induced decreases of sympathetic tone.

  13. Modelling and subject-specific validation of the heart-arterial tree system.

    Science.gov (United States)

    Guala, Andrea; Camporeale, Carlo; Tosello, Francesco; Canuto, Claudio; Ridolfi, Luca

    2015-01-01

    A modeling approach integrated with a novel subject-specific characterization is here proposed for the assessment of hemodynamic values of the arterial tree. A 1D model is adopted to characterize large-to-medium arteries, while the left ventricle, aortic valve and distal micro-circulation sectors are described by lumped submodels. A new velocity profile and a new formulation of the non-linear viscoelastic constitutive relation suitable for the {Q, A} modeling are also proposed. The model is firstly verified semi-quantitatively against literature data. A simple but effective procedure for obtaining subject-specific model characterization from non-invasive measurements is then designed. A detailed subject-specific validation against in vivo measurements from a population of six healthy young men is also performed. Several key quantities of heart dynamics-mean ejected flow, ejection fraction, and left-ventricular end-diastolic, end-systolic and stroke volumes-and the pressure waveforms (at the central, radial, brachial, femoral, and posterior tibial sites) are compared with measured data. Mean errors around 5 and 8%, obtained for the heart and arterial quantities, respectively, testify the effectiveness of the model and its subject-specific characterization.

  14. Serum 25-hydroxyvitamin D is associated with both arterial and ventricular stiffness in healthy subjects.

    Science.gov (United States)

    Şeker, Taner; Gür, Mustafa; Kuloğlu, Osman; Kalkan, Gülhan Yüksel; Şahin, Durmuş Yıldıray; Türkoğlu, Caner; Elbasan, Zafer; Baykan, Ahmet Oytun; Gözübüyük, Gökhan; Çaylı, Murat

    2013-12-01

    Vitamin D regulates the renin-angiotensin system, suppresses proliferation of vascular smooth muscle and improves endothelial cell dependent vasodilatation. These mechanisms may play a role on pathogenesis of arterial and left ventricular stiffness. We aimed to investigate the association between serum 25-hydroxyvitamin D with arterial and left ventricular stiffness in healthy subjects. We studied 125 healthy subjects without known cardiovascular risk factors or overt heart disease (mean age: 60.2 ± 11.9 years). Serum 25-hydroxyvitamin D was measured using a direct competitive chemiluminescent immunoassay. The subjects were divided into two groups according to the serum vitamin D level; vitamin D sufficient (≥ 20 ng/ml, n = 56) and vitamin D deficient (stiffness such as E/A and E/E' were measured. Pulse wave velocity (PWV), which reflects arterial stiffness, was calculated using the single-point method via the Mobil-O-Graph(®) ARC solver algorithm. Systolic blood pressure, level of serum calcium, PWV and E/E' values were higher and E/A values were lower in vitamin D deficient group compared with vitamin D sufficient group. Multiple linear regression analysis showed that vitamin D level was independently associated with E/E' (β = -0.364, pstiffness as well as systolic blood pressure in healthy subjects. Copyright © 2013 Japanese College of Cardiology. Published by Elsevier Ltd. All rights reserved.

  15. Relationship between neck circumference, insulin resistance and arterial stiffness in overweight and obese subjects.

    Science.gov (United States)

    Fantin, Francesco; Comellato, Gabriele; Rossi, Andrea P; Grison, Elisa; Zoico, Elena; Mazzali, Gloria; Zamboni, Mauro

    2017-09-01

    Background Only a few studies have investigated the relationship between neck circumference and cardiometabolic risk. The aim of this study was to assess the relationships between neck circumference, waist circumference, metabolic variables and arterial stiffness in a group of overweight and obese subjects evaluating a possible independent role of neck circumference in determining arterial stiffness. Methods and results We studied 95 subjects (53 women) with an age range of 20-77 years and body mass index range from 25.69 to 47.04 kg/m 2 . In each subject we evaluated body mass index, waist, hip and neck circumference, systolic and diastolic blood pressure, insulin, fasting glucose, cholesterol, low-density lipoprotein and high-density lipoprotein cholesterol and triglycerides. Arterial stiffness was assessed by carotid-femoral pulse wave velocity (PWVcf) and carotid-radial pulse wave velocity (PWVcr). Both PWVcf and PWVcr were higher in subjects with high values of neck circumference compared with subjects with normal values of neck circumference. Subjects with high values of neck circumference and abdominal obesity presented higher values of mean arterial pressure, PWVcr and homeostasis model assessment (HOMA) index and lower values of high-density lipoprotein than subjects with only abdominal obesity. Two models of stepwise multiple regression were performed in order to evaluate the combined effect of independent variables on arterial stiffness. In the first model PWVcf was considered a dependent variable, and age, gender, systolic blood pressure, triglycerides, high-density lipoprotein cholesterol, waist circumference, neck circumference, HOMA index and the use of anti-hypertensive medications were considered independent variables. Age, systolic blood pressure, triglycerides and waist circumference were significant predictors of PWVcf, explaining 65% of its variance. In the second model, in which PWVcr was considered a dependent variable, neck circumference

  16. Impact of Whole Body Cryotherapy at -110 °C on Subjects with Arterial Hypertension.

    Science.gov (United States)

    Missmann, M; Himsl, M; Mur, E; Ulmer, H; Marschang, P

    2016-02-01

    Whole body cryotherapy (WBC) in a cryo-chamber as a medical treatment was first established in Japan in the 1980s, later in Central Europe, and is now becoming more popular also in the United States. The exposure to extreme, non-physiological environmental conditions in a cryo-chamber at -110 °C may exceed the normal adaption capacity. The aim of this study was to investigate the effects of WBC on blood pressure (BP) readings in adult subjects with rheumatic disorders and normal or moderately elevated BP. A sample of 23 subjects (8 female, 15 male) which were recruited according to their pathology between the age of 35 and 69 years undergoing 21 WBC applications was divided into three groups: a group of subjects with anti-hypertensive therapy, a group of subjects with mild arterial hypertension without medical treatment, and a normotensive control-group. A total of 483 BP readings were taken immediately before and after each WBC application. The systolic and diastolic BP were recorded, and the mean arterial pressure, and the amplitude of BP were calculated. A statistically significant rise of BP after WBC was found in the whole sample and in the normotensive group. Over the course of time, no significant change of BP behavior was observed, except for normotensive subjects, who showed a wider range in their systolic BP values. Generally accepted exclusion criteria were applied, and in our sample group WBC was safe with respect to unwanted BP alterations for adult subjects under 70 years-regardless of a pre-existing untreated mild or pharmacologically treated arterial hypertension. Greater changes of BP values might infrequently occur, so an individual monitoring of subjects is necessary.

  17. Exercise Training Reduces Peripheral Arterial Stiffness and Myocardial Oxygen Demand in Young Prehypertensive Subjects

    Science.gov (United States)

    2013-01-01

    BACKGROUND Large artery stiffness is a major risk factor for the development of hypertension and cardiovascular disease. Persistent prehypertension accelerates the progression of arterial stiffness. METHODS Forty-three unmedicated prehypertensive (systolic blood pressure (SBP) = 120–139mm Hg or diastolic blood pressure (DBP) = 80–89mm Hg) men and women and 15 normotensive time-matched control subjects (NMTCs; n = 15) aged 18–35 years of age met screening requirements and participated in the study. Prehypertensive subjects were randomly assigned to a resistance exercise training (PHRT; n = 15), endurance exercise training (PHET; n = 13) or time-control group (PHTC; n = 15). Treatment groups performed exercise training 3 days per week for 8 weeks. Pulse wave analysis, pulse wave velocity (PWV), and central and peripheral blood pressures were evaluated before and after exercise intervention or time-matched control. RESULTS PHRT and PHET reduced resting SBP by 9.6±3.6mm Hg and 11.9±3.4mm Hg, respectively, and DBP by 8.0±5.1mm Hg and 7.2±3.4mm Hg, respectively (P endurance exercise alone effectively reduce peripheral arterial stiffness, central blood pressures, augmentation index, and myocardial oxygen demand in young prehypertensive subjects. PMID:23736111

  18. Exercise training reduces peripheral arterial stiffness and myocardial oxygen demand in young prehypertensive subjects.

    Science.gov (United States)

    Beck, Darren T; Martin, Jeffrey S; Casey, Darren P; Braith, Randy W

    2013-09-01

    Large artery stiffness is a major risk factor for the development of hypertension and cardiovascular disease. Persistent prehypertension accelerates the progression of arterial stiffness. Forty-three unmedicated prehypertensive (systolic blood pressure (SBP) = 120-139 mm Hg or diastolic blood pressure (DBP) = 80-89 mm Hg) men and women and 15 normotensive time-matched control subjects (NMTCs; n = 15) aged 18-35 years of age met screening requirements and participated in the study. Prehypertensive subjects were randomly assigned to a resistance exercise training (PHRT; n = 15), endurance exercise training (PHET; n = 13) or time-control group (PHTC; n = 15). Treatment groups performed exercise training 3 days per week for 8 weeks. Pulse wave analysis, pulse wave velocity (PWV), and central and peripheral blood pressures were evaluated before and after exercise intervention or time-matched control. PHRT and PHET reduced resting SBP by 9.6±3.6mm Hg and 11.9±3.4mm Hg, respectively, and DBP by 8.0±5.1mm Hg and 7.2±3.4mm Hg, respectively (P endurance exercise alone effectively reduce peripheral arterial stiffness, central blood pressures, augmentation index, and myocardial oxygen demand in young prehypertensive subjects.

  19. Arterial Carboxyhemoglobin Measurement Is Useful for Evaluating Pulmonary Inflammation in Subjects with Interstitial Lung Disease.

    Science.gov (United States)

    Hara, Yu; Shinkai, Masaharu; Kanoh, Soichiro; Fujikura, Yuji; K Rubin, Bruce; Kawana, Akihiko; Kaneko, Takeshi

    2017-01-01

    Objective The arterial concentration of carboxyhemoglobin (CO-Hb) in subjects with inflammatory pulmonary disease is higher than that in healthy individuals. We retrospectively analyzed the relationship between the CO-Hb concentration and established markers of disease severity in subjects with interstitial lung disease (ILD). Methods The CO-Hb concentration was measured in subjects with newly diagnosed or untreated ILD and the relationships between the CO-Hb concentration and the serum biomarker levels, lung function, high-resolution CT (HRCT) findings, and the uptake in gallium-67 ( 67 Ga) scintigraphy were evaluated. Results Eighty-one non-smoking subjects were studied (mean age, 67 years). Among these subjects, (A) 17 had stable idiopathic pulmonary fibrosis (IPF), (B) 9 had an acute exacerbation of IPF, (C) 44 had stable non-IPF, and (D) 11 had an exacerbation of non-IPF. The CO-Hb concentrations of these subjects were (A) 1.5±0.5%, (B) 2.1±0.5%, (C) 1.2±0.4%, and (D) 1.7±0.5%. The CO-Hb concentration was positively correlated with the serum levels of surfactant protein (SP)-A (r=0.38), SP-D (r=0.39), and the inflammation index (calculated from HRCT; r=0.57) and was negatively correlated with the partial pressure of oxygen in the arterial blood (r=-0.56) and the predicted diffusion capacity of carbon monoxide (r=-0.61). The CO-Hb concentrations in subjects with a negative heart sign on 67 Ga scintigraphy were higher than those in subjects without a negative heart sign (1.4±0.5% vs. 1.1±0.3%, p=0.018). Conclusion The CO-Hb levels of subjects with ILD were increased, particularly during an exacerbation, and were correlated with the parameters that reflect pulmonary inflammation.

  20. Arterial stiffness evaluation by cardio-ankle vascular index in hypertension and diabetes mellitus subjects.

    Science.gov (United States)

    Wang, Hongyu; Liu, Jinbo; Zhao, Hongwei; Fu, Xiaobao; Shang, Guangyun; Zhou, Yingyan; Yu, Xiaolan; Zhao, Xujing; Wang, Guang; Shi, Hongyan

    2013-01-01

    Arterial stiffness is an independent predictor for vascular diseases. Cardio-ankle vascular index (CAVI) is a new index of arterial stiffness. In the present study, we investigated the possible risk factors involving CAVI in hypertension and diabetes mellitus (DM) subjects. One thousand sixty-three subjects (M/F 533/530) from Shougang Corporation Examination Center were divided into four groups: healthy group (n = 639); hypertension group (n = 312); DM group (n = 58); and hypertension with DM group (n = 54). CAVI was measured by VS-1000 apparatus. Our results showed that CAVI was significantly higher in hypertension subjects with DM than in healthy and hypertension group, respectively (8.59 ± 1.08 vs 7.23 ± 1.10; 8.59 ± 1.08 vs 7.94 ± 1.33; both P hypertension subjects with DM compared with healthy and hypertension groups. Copyright © 2013 American Society of Hypertension. Published by Elsevier Inc. All rights reserved.

  1. The realistic dilemma of environmental interest subject of legal responsibility—Based on the perspective of law and economics

    Science.gov (United States)

    Fa, L. N.

    2017-11-01

    As the important environmental interests subject, enterprises, public and government should assume the corresponding responsibility of pollution control and environmental protection. However, in the aspect of environment, there are failure existing in performing government responsibility, the financial expense and investment our government has participated in the aspects of pollution control and environmental protection are serious insufficient. In the meantime, in spite of the clear definition of the range and principles of enterprises’ environmental responsibility according to some corresponding law documents, in view of our country’s condition, enterprises always fail to assume their own environmental responsibility, and there are cases existing in pollution control and environmental protection that the investment is insufficient and the treatment effect is not obvious. In addition, it is especially outstanding in our country that the awareness of public environmental rights is pretty weak. The issues of ecological damage and environmental pollution get worse and worse and the total environmental interests get injured seriously because of the failure and vacancy of environmental responsibility of different subjects of right.

  2. Epicardial adipose tissue as a predictor of coronary artery disease in asymptomatic subjects.

    Science.gov (United States)

    Bachar, Gil N; Dicker, Dror; Kornowski, Ran; Atar, Eli

    2012-08-15

    This study sought to elucidate the relation between epicardial adipose tissue (EAT) thickness measured by multidetector computed tomography and presence of coronary artery atherosclerosis. Recent studies have suggested that fat disposition in visceral organs and epicardial tissue could serve as a predictor of coronary artery disease (CAD). The sample included 190 asymptomatic subjects with ≥ 1 cardiovascular risk factor who were referred for cardiac computed tomographic angiography. Body mass index, blood pressure, fasting glucose level, and lipid profile were measured. Multidetector computed tomographic results were analyzed for atherosclerosis burden, calcium Agatston score, and EAT thickness: mean EAT values were 3.54 ± 1.59 mm in patients with atherosclerosis and 1.85 ± 1.28 mm in patients without atherosclerosis (p 50% diameter) coronary artery stenosis. There was a significant difference in EAT values between patients with and without metabolic syndrome (2.58 ± 1.63 vs 2.04 ± 1.46 mm, p 400 and <400 (3.38 ± 1.58 vs 2.02 ± 1.42 mm, p <0.0001). In conclusion, asymptomatic patients with CAD have significantly more EAT than patients without CAD. An EAT thickness of 2.4 mm is the optimal cutoff for prediction of presence of significant CAD. Copyright © 2012 Elsevier Inc. All rights reserved.

  3. Impact of acute caffeine ingestion on endothelial function in subjects with and without coronary artery disease.

    Science.gov (United States)

    Shechter, Michael; Shalmon, Guy; Scheinowitz, Mickey; Koren-Morag, Nira; Feinberg, Micha S; Harats, Dror; Sela, Ben Ami; Sharabi, Yehonatan; Chouraqui, Pierre

    2011-05-01

    Although coffee is a widely used, pharmacologically active beverage, its impact on the cardiovascular system is controversial. To explore the effect of acute caffeine ingestion on brachial artery flow-mediated dilation (FMD) in subjects without coronary artery disease (CAD; controls) and patients with CAD, we prospectively assessed brachial artery FMD in 40 controls and 40 age- and gender-matched patients with documented stable CAD on 2 separate mornings 1 week to 2 weeks apart. After overnight fasting, discontinuation of all medications for ≥12 hours, and absence of caffeine for >48 hours, participants received capsules with caffeine 200 mg or placebo. One hour after drug ingestion, participants underwent brachial artery FMD and nitroglycerin-mediated dilation (NTG) using high-resolution ultrasound. As expected, patients with CAD were more often diabetic, hypertensive, obese, dyslipidemic, and smoked more than controls (p <0.01 for all comparisons). Aspirin, Clopidogrel, angiotensin-converting enzyme inhibitors, β blockers, and statins were significantly more common in patients with CAD than in controls (p <0.01 for all comparisons). At baseline, FMD, but not NTG, was significantly lower in patients with CAD compared to controls. Acute caffeine ingestion significantly increased FMD (patients with CAD 5.6 ± 5.0% vs 14.6 ± 5.0%, controls 8.4 ± 2.9% vs 18.6 ± 6.8%, p <0.001 for all comparisons) but not NTG (patients with CAD 13.0 ± 5.2% vs 13.8 ± 6.1%, controls 12.9 ± 3.9% vs 13.9 ± 5.8%, p = NS for all comparisons) and significantly decreased high-sensitivity C-reactive protein (patients with CAD 2.6 ± 1.4 vs 1.4 ± 1.2 mg/L, controls 3.4 ± 3.0 vs 1.2 ± 1.0 mg/L, p <0.001 for all comparisons) in the 2 groups compared to placebo. In conclusion, acute caffeine ingestion significantly improved endothelial function assessed by brachial artery FMD in subjects with and without CAD and was associated with lower plasma markers of inflammation. Copyright

  4. The prevalence of peripheral arterial disease in diabetic subjects in south-west Nigeria

    Directory of Open Access Journals (Sweden)

    Bolaji O. Oyelade

    2012-10-01

    Full Text Available Background: Peripheral arterial disease (PAD is rarely sought for and generally underdiagnosed even in diabetics in developing countries like Nigeria. PAD is easily detected and diagnosed by the ankle-brachial index, a simple and reliable test. Objectives: To determine the prevalence of PAD in diabetic subjects aged 50–89 years and the value of ankle-brachial index measurement in the detection of PAD. Method: A cross-sectional descriptive study of 219 diabetic subjects aged 50–89 years was carried out. The participants were administered a pre-tested questionnaire and measurement of ankle-brachial index (ABI was done. The ankle-brachial index < 0.90 was considered equivalent to peripheral arterial disease. Results: The overall prevalence of PAD was 52.5%. The prevalence of symptomatic PAD was 28.7% whilst that of asymptomatic PAD was 71.3%. There were a number of associations with PAD which included, age (p < 0.05, sex (p < 0.05, and marital status (p < 0.05. The use of the ankle-brachial index in the detection of PAD was clearly more reliable than the clinical methods like history of intermittent claudication and absence or presence of pedal pulses. Conclusion: The prevalence of PAD is relatively high in diabetic subjects in the southwestern region of Nigeria. Notable is the fact that a higher proportion was asymptomatic. Also the use of ABI is of great value in the detection of PAD as evidenced by a clearly more objective assessment of PAD compared to both intermittent claudication and absent pedal pulses.

  5. Decreased muscle mass in Korean subjects with intracranial arterial stenosis: The Kangbuk Samsung Health Study.

    Science.gov (United States)

    Jung, Ho-Jung; Jung, Hwanseok; Lee, Taeyoung; Kim, Jongho; Park, Jongsin; Kim, Hacsoo; Cho, Junghwan; Lee, Won-Young; Park, Sung-Woo; Rhee, Eun-Jung; Oh, Hyung-Geun

    2017-01-01

    Intracranial arterial stenosis (ICAS) is a common cause of ischemic stroke in Asians. Decreased muscle mass is one of the major causes of chronic disease in adults. The purpose of this study was to analyze the relationship between muscle mass and ICAS in Korean adults. For this study, we selected a total of 10,530 participants (mean age, 43.3 years; 8558 men) in a health screening program, for whom transcranial Doppler (TCD) ultrasound was used to detect >50% ICAS based on criteria modified from the stroke outcomes and neuroimaging of intracranial atherosclerosis trial. Body composition was evaluated by bioelectrical impedance analysis (BIA). Skeletal muscle index (SMI) was calculated with muscle mass/weight (kg) * 100. Among the total patient population, 322 (3.1%) subjects had ICAS. Subjects with ICAS were older, and had higher mean values for fasting glucose, body mass index and blood pressure compared with those without ICAS. Subjects with ICAS had significantly lower muscle mass, SMI and higher percent body fat compared with those without ICAS. In logistic regression analysis, the subjects in the highest tertile of muscle mass had the lowest odds ratio for ICAS with the lowest tertile group of muscle mass as the reference group even after adjusting for age, systolic blood pressure, fasting blood glucose, sex, smoking and exercise (OR 0.650, 95% CI 0.442-0.955). Subjects with ICAS had significantly decreased muscle mass compared with those without ICAS in Korean adults. The risk for ICAS was lower in subjects with higher muscle mass. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  6. Association of plasma fetuin-a levels with peripheral arterial disease and lower extremity arterial calcification in subjects with type 2 diabetes mellitus.

    Science.gov (United States)

    Eleftheriadou, Ioanna; Grigoropoulou, Pinelopi; Kokkinos, Alexander; Mourouzis, Iordanis; Perrea, Despoina; Katsilambros, Nicholas; Sfikakis, Petros P; Tentolouris, Nikolaos

    2017-03-01

    Fetuin-A is a hepatic glycoprotein that is involved in insulin resistance and atherosclerosis. Herein we examined the association of plasma fetuin-A levels with peripheral arterial disease (PAD) in patients with type 2 diabetes mellitus (T2DM). A total of 71 patients with T2DM and 57 non-diabetic individuals were recruited. Diagnosis of PAD was based on the absence of triphasic waveform at pedal arteries, while ankle-brachial index (ABI) was calculated. Radiographs of both feet and ankles were taken for the assessment of lower extremity arterial calcification (LEAC). Plasma fetuin-A levels were measured using ELISA. Patients with T2DM had higher fetuin-A levels than non-diabetic participants. Participants with diabetes and PAD had lower fetuin-A levels than non-PAD diabetic patients. In subjects with T2DM fetuin-A levels were associated with ABI. Multivariate analysis demonstrated that in patients with T2DM the odds of PAD increased with long diabetes duration, smoking, presence of arterial hypertension and dyslipidemia, as well as with lower fetuin-A levels. A trend towards higher fetuin-A levels in subjects with less severe LEAC was found. Plasma fetuin-A levels are lower in patients with T2DM and PAD and are associated with PAD, irrespective of traditional cardiovascular risk factors. Moreover, fetuin-A may be involved in arterial calcification. Copyright © 2016 Elsevier Inc. All rights reserved.

  7. Etiology of chronic skin lesions in subjects with peripheral arterial disease.

    Science.gov (United States)

    Chisari, G; Chisari, E M; Borzì, A M; Grasso, A; Chisari, C G

    2018-01-01

    Skin lesions can be defined as lesions that result in loss of tissues and their joints, and often this cutaneous skin process is a primary or secondary consequence of the structural changes in the skin itself. Subjects with peripheral arteripathies that develop chronic skin lesions in the lower extremities of the Western world are constantly increasing. We conducted a study on the etiologic incidence of chronic skin lesions in peripheral arterial disease CSLpa subjects in the lower limbs compared to subjects with chronic skin lesions CSL (controls). 30 subjects with peripheral atheropathies PA (22 F - 8 M mean age 74,5 ± 4,9) and with chronic skin lesions (CSLpa) in the lower limbs "A" group were admitted to our study according to a randomized and compared to 30 no peripheral atheropathies subjects (19 F-11 M, mean age 81,5 ± 7,3 - controls) group B with chronic skin lesions (CSL). These two groups "A" and "B" have been studied and compared on the basis of infectious etiology responsible for the infectious skin process. In the subjects of the "A" group we found a 12 positive assay of 40.0% of the examinations, while in the group "B" we achieved a total cultured positivity of 9 cases corresponding to 30.0% of the examinations . For the number of bacterial species identified for "A" group we obtained 3 mono microbial and 6 poly microbial bacteriological tests and for group "B" we observed 7 mono microbial and 2 poly microbial tests. All bacteriological isolates showed "in vitro" sensitivity to satisfactory ciprofloxacin with MICs range of 0.78-1.56mg/L. The data observed after 4 weeks after the amniotic membrane (MA) in the two study groups A and B were respectively the following: and for group A 50% scarring, 46.6% partial resolution and in one case worsening for the B-healing group in 63.3%, the partial resolution in the remaining 36.6. The data from this study show a different etiology between subjects with CSLpa than subjects with CSL. This phenomenon confirms

  8. Prevalence of middle cerebral artery stenosis in asymptomatic subjects of more than 40 years age group: a transcranial Doppler study.

    Science.gov (United States)

    Sada, Sujay; Reddy, Yugandhar; Rao, Sampath; Alladi, Suvarna; Kaul, Subash

    2014-01-01

    Middle cerebral artery (MCA) disease is the most common vascular lesion in stroke. Transcranial Doppler (TCD) is a non-invasive bedside screening method for assessing cerebral blood flow. To investigate the prevalence of MCA stenosis in asymptomatic but high-risk individuals for stroke. Prospective study between December 2011 and December 2013. Vascular risk factors considered included: hypertension (HTN), diabetes mellitus, smoking, alcohol consumption, coronary artery disease (CAD), peripheral vascular disease (PVD), hypercholesterolemia and obesity. TCD was performed with portable machine through the temporal windows by use of a standardized protocol. Of the 427 subjects, 374 were analyzed; males 264 (70.6%) and females 110 (29.4%). Mean age was 54.2 ± 7.6 years. The frequency of the risk factors was: HTN 287 (76.7%), diabetes 220 (58.8%), CAD 120 (32.1%), hypercholesterolemia 181 (48.4%), smoking 147 (39.3%), alcohol 99 (26.5%), obesity 198 (52.9%) and PVD 8 (2.1%). Of the 374 subjects, 27 (7.2%) had intracranial arterial stenosis and the rest had normal intracranial arteries. On univariate analysis, subjects with higher age, HTN, CAD, smoking and hypercholesterolemia had higher risk of having intracranial arterial stenosis (P < 0.05). Multivariate analysis showed HTN and CAD are independent risk factors for intracranial arterial stenosis. Overall prevalence of intracranial arterial stenosis is 7.2% in high-risk population sample from Hyderabad in South India. HTN and CAD are independent risk factors for the development of intracranial arterial stenosis.

  9. Bronchial hyperreactivity and arterial carboxyhemoglobin as detectors of air pollution in Milan: a study on normal subjects

    Energy Technology Data Exchange (ETDEWEB)

    Clini, V.; Pozzi, G.; Ferrara, A.

    1985-01-01

    Research has been carried out in the town area of Milan on 275 subjects. For each patient the following data have been measured: ventilatory profile, aspecific bronchial reactivity, arterial concentration in CO and acid-base balance. The results obtained have been divided into four groups, according to the level of SO/sub 2/ in the area of residence of the subjects, who have also been studied with reference to the habit of smoking. The data obtained have shown (1) an alteration of the ventilatory function, with decrease of oxygen tension in arterial blood in all subjects. (2) Increase of bronchial irritability and CO concentration in arterial blood have been found in these subjects. (3) The division of the results according to the level of SO/sub 2/ pollution in the areas of residence of the patients showed the presence, in the most polluted areas of Milan (NE and SW), of higher levels of bronchial irritability and higher CO rates in arterial blood. (4) Cigarette smoking does not seem to play a major role in causing bronchial irritability. It certainly increases CO concentration: smokers have HbCO concentration higher than nonsmokers in all four areas. (5) Air pollution is more important than cigarette smoking in determining CO saturation of blood. Nonsmokers living in the most polluted areas of Milan (NE) show a higher concentration of CO in arterial blood than smokers living in the less polluted areas (SW).

  10. Correlation between spirometry values and pulmonary artery pressure in young healthy subjects.

    Science.gov (United States)

    Grossman, Alon; Benderly, Michal; Prokupetz, Alex; Gordon, Barak; Kalter-Leibovici, Ofra

    2014-03-01

    Pulmonary hypertension is frequently associated with parenchymal lung disease. We evaluated the association between spirometry values and pulmonary artery systolic pressure (PASP) in young subjects without lung disease : We studied applicants to the Israeli Air Force, who undergo routine evaluation that includes resting spirometry and echocardiography. Applicants with overt lung disease were excluded. All echocardiographic studies performed in the years 1994 through 2010 (n = 6,598) were screened, and files that included PASP and spirometry values were analyzed for the association between PASP and FVC, FEV1, FEV1/FVC, peak expiratory flow, and forced expiratory flow during the middle half of the FVC maneuver. Of the 647 air force applicants who underwent echocardiography in which PASP was measurable and had spirometry data, 607 (94%) were male, and their average age was 18.16 ± 0.73 years. Mean PASP was 26.4 ± 5.2 mm Hg (range 10-41 mm Hg). None of the spirometry values significantly correlated with PASP. PASP in young healthy subjects is not significantly associated with spirometry values. Lung mechanics probably do not contribute significantly to PASP in this population.

  11. Fasting plasma glucose levels and coronary artery calcification in subjects with impaired fasting glucose.

    Science.gov (United States)

    Eun, Young-Mi; Kang, Sung-Goo; Song, Sang-Wook

    2016-01-01

    Prediabetes is associated with an increased risk of cardiovascular disease (CVD). While the association of impaired glucose tolerance with CVD has been shown in many studies, the relationship between impaired fasting glucose (IFG) and CVD remains unclear. The purpose of this study was to compare the coronary artery calcium (CAC) scores of participants with normal fasting glucose versus those with IFG, according to fasting plasma glucose (FPG) levels, and to assess whether differences in CAC scores were independent of important confounders. Retrospective study. Health Promotion Center of the University Hospital (Gyeonggi-do, South Korea), during the period 2010-2014. Participants were enrolled from the general population who visited for a medical check-up. CAC was assessed in asymptomatic individuals by multidetector computed tomography. Anthropometric parameters and metabolic profiles were also recorded. Subjects were divided into four fasting glucose groups. Participants with a history of CVD or diabetes mellitus were excluded. Correlation between FPG and CAC scores, CAC score categories, and association between CAC score and FPG categories. Of 1112 participants, 346 (34.2%) had a CAC score > 0. FPG values in the IFG patients were positively but weakly correlated with CAC scores (r=0.099, P=.001). The incidence of CAC differed according to FPG level (P =110 mg/dL had a significantly higher risk of CAC than did subjects with normal fasting glucose (110.

  12. Cerebral small-resistance artery structure and cerebral blood flow in normotensive subjects and hypertensive patients

    Energy Technology Data Exchange (ETDEWEB)

    De Ciuceis, Carolina; Porteri, Enzo; Rizzoni, Damiano; Boari, Gianluca E.M.; Rosei, Enrico Agabiti [University of Brescia, Clinica Medica, Department of Clinical and Experimental Sciences, Brescia (Italy); Cornali, Claudio; Mardighian, Dikran; Fontanella, Marco M. [University of Brescia, Section of Neurosurgery, Department of Medical and Surgical Specialties, Radiological Sciences and Public Health, Brescia (Italy); Pinardi, Chiara [Spedali Civili, Medical Physics Unit, Brescia (Italy); University of Brescia, Section of Neuroradiology, Department of Medical and Surgical Specialties, Radiological Sciences and Public Health, Brescia (Italy); Rodella, Luigi F.; Rezzani, Rita [University of Brescia, Section of Anatomy, Department of Clinical and Experimental Sciences, Brescia (Italy); Gasparotti, Roberto [University of Brescia, Section of Neurosurgery, Department of Medical and Surgical Specialties, Radiological Sciences and Public Health, Brescia (Italy); University of Brescia, Section of Neuroradiology, Department of Medical and Surgical Specialties, Radiological Sciences and Public Health, Brescia (Italy)

    2014-12-15

    The aim of this study was to prospectively investigate whether the structure of cerebral small-resistance arteries is related to cerebral perfusion parameters as measured with dynamic susceptibility-weighted contrast magnetic resonance imaging (DSC-MRI) in a selected cohort of hypertensive and normotensive patients. Ten hypertensive and 10 normotensive patients were included in the study. All patients underwent neurosurgical intervention for an intracranial tumor and were investigated with DSC-MRI at 1.5 T. Cerebral small-resistance arteries were dissected from a small portion of morphologically normal cerebral tissue and mounted on an isometric myograph for the measurement of the media-to-lumen (M/L) ratio. A quantitative assessment of cerebral blood flow (CBF) and volume (CBV) was performed with a region-of-interest approach. Correlation coefficients were calculated for normally distributed variables. The institutional review board approved the study, and informed consent was obtained from all patients. Compared with normotensive subjects, hypertensive patients had significantly lower regional CBF (mL/100 g/min) in the cortical grey matter (55.63 ± 1.90 vs 58.37 ± 2.19, p < 0.05), basal ganglia (53.34 ± 4.39 vs 58.22. ± 4.33, p < 0.05), thalami (50.65 ± 3.23 vs 57.56 ± 4.45, p < 0.01), subcortical white matter (19.32 ± 2.54 vs 22.24 ± 1.9, p < 0.05), greater M/L ratio (0.099 ± 0.013 vs 0.085 ± 0.012, p < 0.05), and lower microvessel density (1.66 ± 0.67 vs 2.52 ± 1.28, p < 0.05). A statistically significant negative correlation was observed between M/L ratio of cerebral arteries and CBF in the cortical grey matter (r = -0.516, p < 0.05), basal ganglia (r = -0.521, p < 0.05), thalami (r = -0.527 p < 0.05), and subcortical white matter (r = -0.612, p < 0.01). Our results indicate that microvascular structure might play a role in controlling CBF, with possible clinical consequences. (orig.)

  13. Arterial stiffness in normotensive and hypertensive subjects: Frequency in community pharmacies.

    Science.gov (United States)

    Rodilla Sala, Enrique; Adell Alegre, Manuel; Giner Galvañ, Vicente; Perseguer Torregrosa, Zeneida; Pascual Izuel, Jose Maria; Climent Catalá, María Teresa

    2017-12-07

    Arterial stiffness (AS) is a well-recognized target organ lesion. This study aims to determine: 1) the frequency of AS in community pharmacies; 2) if stiffened subjects identified by brachial oscillometry have more CV risk factors than normal subjects, and 3) the dependence of stiffness on using either age-adjusted values or a fixed threshold. Observational, cross-sectional study in 32 community pharmacies of the Valencia Community, between November/2015 and April/2016. Stiffness was as pulse wave velocity (PWV) measured with a semi-automatic, validated device (Mobil-O-Graph ® , IEM), followed by a 10-item questionnaire. Mean age of the 1,427 consecutive recruited patients was 56.6 years. Overall proportion of patients with AS was 17.4% with age-adjusted PWV (9.4% in normotensives, 28.3% in hypertensives). Multivariate logistic regression showed independent association of stiffness in normotensives with male gender, obesity, higher pulse pressure and heart rate, in hypertensives, with higher pulse pressure and lower age. AS was globally found in 20.5% of subjects, defining stiffness by PWV>10m/s (6.2% in normotensives, 40.2% in hypertensives). It was associated with higher age and pulse pressure in both groups. Concordance in classifying stiffness was 74.6%. Frequency of AS varied between 17.4-20.5%. Age-adjusted stiffness is associated in normotensives with male gender, pulse pressure, obesity and heart rate, in hypertensives with pulse pressure and inversely to age. Stiffness by 10m/s is determined by higher pulse pressure and higher age. Both definitions of PWV are not interchangeable. Copyright © 2017 Elsevier España, S.L.U. All rights reserved.

  14. Glycemic markers and relation with arterial stiffness in Caucasian subjects of the MARK study.

    Directory of Open Access Journals (Sweden)

    Leticia Gomez-Sanchez

    Full Text Available Effect of prediabetes and normal glucose on arterial stiffness remains controversial. The primary aim of this study was to investigate the relationship of fasting plasma glucose (FPG, postprandial glucose (PG and glycosylated haemoglobin (HbA1c with brachial-ankle pulse wave velocity (baPWV and cardio-ankle vascular index (CAVI in Caucasian adults. The secondary aim was to analyse this relationship by glycaemic status.Cross-sectional study. Setting: Primary care. Participants: 2,233 subjects, 35-74 years. Measures: FPG (mg/dL and HbA1c (% of all subjects were measured using standard automated enzymatic methods. PG (mg/dL was self-measured at home two hours after meals (breakfast, lunch and dinner for one day using an Accu-chek ® glucometer. CAVI was measured using a VaSera VS-1500® device (Fukuda Denshi, and baPWV was calculated using a validated equation.CAVI and baPWV values were significantly higher in subjects with diabetes mellitus than in glucose normal and prediabetes groups (p<0.001. FPG, PG and HbA1c were positively associated with CAVI and baPWV. The β regression coefficient for: HbA1c was 0.112 (CI 95% 0.068 to 0.155 with CAVI, 0.266 (CI 95% 0.172 to 0.359 with baPWV; for PG was 0.006 (CI 95% 0.004 to 0.009 and for FPG was 0.005 (CI 95% 0.002 to 0.008 with baPWV; and for PG was 0.002 (CI 95% 0.001 to 0.003 and 0.003 (CI 95% 0.002 to 0.004 with CAVI (p<0.01 in all cases. When analysing by hyperglycaemic status, FPG, PG and HbA1c were positively associated with CAVI and baPWV in subjects with type 2 diabetes mellitus.FPG, PG and HbA1c show a positive association with CAVI and baPWV, in Caucasian adults with intermediate cardiovascular risk factors. When analysing by hyperglycaemic status, the association is only maintained in subjects with type 2 diabetes mellitus.Clinical Trials.gov Identifier: NCT01428934. Registered 2 September 2011. Retrospectively registered. Last updated September 8, 2016.

  15. Echocardiographic evaluation of the arterial stiffness in healthy subjects and hypertensive patients under 60 years

    International Nuclear Information System (INIS)

    Valiente Mustelier, Juan; Suarez Vazquez, Leisy; Cabrera Rego, Julio Oscar; Gandarilla Sarmientos, Julio Cesar

    2011-01-01

    We conducted a cross-sectional study that included 83 patients (healthy, n=43; hypertensive, n=40) assisted in the external consultation of the National Cardiology and Cardiovascular Surgery Institute, from April to October, 2009. We included clinical (age, sex, personal antecedents of smoking habit, obesity, hypercholesterolemia, arterial hypertension) and echocardiographic (diastolic function, arterial stiffness index [β], pressure strain elastic modulus [Ep], arterial compliance, local pulse wave velocity [LPWV]) variables

  16. Quantitative thallium-201 myocardial exercise scintigraphy in normal subjects and patients with normal coronary arteries

    International Nuclear Information System (INIS)

    Niemeyer, M.G.; St. Antonius Hospital Nieuwegein; Laarman, G.J.; Lelbach, S.; Cramer, M.J.; Ascoop, C.A.P.L.; Verzijlbergen, J.F.; Wall, E.E. van der; Zwinderman, A.H.; Pauwels, E.K.J.

    1990-01-01

    Quantitative thallium-201 myocardial exercise scintigraphy was tested in two patient populations representing alternative standards for cardiac normality: group I comprised 18 male uncatherized patients with a low likelihood of coronary artery disease (CAD); group II contained 41 patients with normal coronary arteriograms. Group I patients were younger, they achieved a higher rate-pressure product than group II patients; all had normal findings by phisical examination and electrocardiography at rest and exercise. Group II patients comprised 21 females, 11 patients showed abnormal electrocardiography at rest, and five patients showed ischemic ST depression during exercise. Twelve patients had sign of minimal CAD. Twelve patients revealed abnormal visual and quantitative thallium findings, three of these patients had minimal CAD. Profiles of uptake and washout of thallium-201 were derived from both patient groups, and compared with normal limits developed by Maddahi et al. Furthermore, low likelihood and angiographically normal patients may differ substantially, and both sets of normal patients should be considered when establishing criteria of abnormality in exercise thallium imaging. When commercial software containing normal limits for quantitative analysis of exercise thallium-201 imaging is used in clinical practice, it is mandatory to compare these with normal limits of uptake and washout of thallium-201, derived from the less heterogeneous group of low-likelihood subjects, which should be used in selecting a normal population to define normality. (author). 37 refs.; 3 figs; 1 tab

  17. Body Mass Index and Subjective Social Status: The Coronary Artery Risk Development in Young Adults Study.

    Science.gov (United States)

    Dhurandhar, Emily J; Pavela, Gregory; Kaiser, Kathryn A; Dutton, Gareth R; Fontaine, Kevin R; Kim, Daniel; Shikany, James M; Allison, David B; Lewis, Cora E

    2018-02-01

    Subjective social status (SSS), or perceived social status, may explain, in part, the relationship between socioeconomic status (SES) and obesity. The objective of this study was to test whether SSS mediates the relationship between two indicators of SES (income and education) and body mass index (BMI). A cross-sectional, structural equation path analysis was applied to the Coronary Artery Risk Development in Young Adults (CARDIA) study (n = 2,624). The analysis tested whether SSS (MacArthur scale), education, and income were associated with BMI at the year 20 examination (adjusting for sex, age, and race), and it was hypothesized that the associations of education and income with BMI would be at least partly mediated by SSS. SSS had a significant direct effect on BMI (-0.21, P = 0.018). Education had a significant direct relationship with SSS (0.11, P SSS (-0.02, P = 0.022). Although income did not have a significant direct relationship with BMI, it did have a significant indirect relationship through SSS (b = -0.05, P = 0.019). Results are consistent with the hypothesized model in which SSS partially mediates the relationship between SES indicators and BMI. © 2017 The Obesity Society.

  18. Measuring Electromechanical Coupling in Patients with Coronary Artery Disease and Healthy Subjects

    Directory of Open Access Journals (Sweden)

    Lizhen Ji

    2016-04-01

    Full Text Available Coronary artery disease (CAD is the most common cause of death globally. To detect CAD noninvasively at an early stage before clinical symptoms occur is still nowadays challenging. Analysis of the variation of heartbeat interval (RRI opens a new avenue for evaluating the functional change of cardiovascular system which is accepted to occur at the subclinical stage of CAD. In addition, systolic time interval (STI and diastolic time interval (DTI also show potential. There may be coupling in these electromechanical time series due to their physiological connection. However, to the best of our knowledge no publication has systematically investigated how can the coupling be measured and how it changes in CAD patients. In this study, we enrolled 39 CAD patients and 36 healthy subjects and for each subject the electrocardiogram (ECG and photoplethysmography (PPG signals were recorded simultaneously for 5 min. The RRI series, STI series, and DTI series were constructed, respectively. We used linear cross correlation (CC, coherence function (CF, as well as nonlinear mutual information (MI, cross conditional entropy (XCE, cross sample entropy (XSampEn, and cross fuzzy entropy (XFuzzyEn to analyse the bivariate RRI-DTI coupling, RRI-STI coupling, and STI-DTI coupling, respectively. Our results suggest that the linear CC and CF generally have no significant difference between the two groups for all three types of bivariate coupling. The MI only shows weak change in RRI-DTI coupling. By comparison, the three entropy-based coupling measurements show significantly decreased coupling in CAD patients except XSampEn for RRI-DTI coupling (less significant and XCE for STI-DTI and RRI-STI coupling (not significant. Additionally, the XFuzzyEn performs best as it was still significant if we further applied the Bonferroni correction in our statistical analysis. Our study indicates that the intrinsic electromechanical coupling is most probably nonlinear and can better

  19. Radioimmunological thromboxane concentrations in arterial blood of cigarette smokers and hypertensive subjects

    International Nuclear Information System (INIS)

    Krause, F.J.

    1987-01-01

    Thromboxane concentrations were investigated in the arterial plasma of 79 patients (24 smokers, 23 nonsmokers, 16 hypertensives, 16 normotensives) with periphered obstructive arterial disease. The thromboxane investigation was made by radioimmunoassay, whose realization was modified. The results indicate that nonsmokers have significantly lower thromboxane levels than smokers, whereas there is no statistically significant difference between hypertensives and normotensives. The findings coincide with the increased risk for arteriosclerosis of smokers, that doesn't work for hypertensives. (orig.) [de

  20. Autonomic and Vascular Control in Prehypertensive Subjects with a Family History of Arterial Hypertension

    Directory of Open Access Journals (Sweden)

    Josária Ferraz Amaral

    2018-02-01

    Full Text Available Abstract Background: Individuals with a family history of systemic arterial hypertension (FHSAH and / or prehypertension have a higher risk of developing this pathology. Objective: To evaluate the autonomic and vascular functions of prehypertensive patients with FHSAH. Methods: Twenty-five young volunteers with FHSAH, 14 normotensive and 11 prehypertensive subjects were submitted to vascular function evaluation by forearm vascular conductance(VC during resting and reactive hyperemia (Hokanson® and cardiac and peripheral autonomic modulation, quantified, respectively, by spectral analysis of heart rate (ECG and systolic blood pressure (SBP (FinometerPRO®. The transfer function analysis was used to measure the gain and response time of baroreflex. The statistical significance adopted was p ≤ 0.05. Results: Pre-hypertensive individuals, in relation to normotensive individuals, have higher VC both at rest (3.48 ± 1.26 vs. 2.67 ± 0.72 units, p = 0.05 and peak reactive hyperemia (25, 02 ± 8.18 vs. 18.66 ± 6.07 units, p = 0.04. The indices of cardiac autonomic modulation were similar between the groups. However, in the peripheral autonomic modulation, greater variability was observed in prehypertensive patients compared to normotensive individuals (9.4 [4.9-12.7] vs. 18.3 [14.8-26.7] mmHg2; p < 0.01 and higher spectral components of very low (6.9 [2.0-11.1] vs. 13.5 [10.7-22.4] mmHg2, p = 0.01 and low frequencies (1.7 [1.0-3.0] vs. 3.0 [2.0-4.0] mmHg2, p = 0.04 of SBP. Additionally, we observed a lower gain of baroreflex control in prehypertensive patients compared to normotensive patients (12.16 ± 4.18 vs. 18.23 ± 7.11 ms/mmHg, p = 0.03, but similar delay time (-1.55 ± 0.66 vs. -1.58 ± 0.72 s, p = 0.90. Conclusion: Prehypertensive patients with FHSAH have autonomic dysfunction and increased vascular conductance when compared to normotensive patients with the same risk factor.

  1. Anatomy of Atrioventricular Node Artery and Pattern of Dominancy in Normal Coronary Subject: A Comparison between Individuals with and without Isolated Right Bundle Branch Block.

    Science.gov (United States)

    Kazemisaeid, Ali; Pakbaz, Marziyeh; Yaminisharif, Ahmad; Davoodi, Gholamreza; Lotfi Tokaldany, Masoumeh; Hakki Kazazi, Elham

    2012-11-01

    Isolated right bundle branch block (RBBB) is a common finding in the general population. The atrioventricular node (AVN) artery contributes to the blood supply of the right bundle branch. Our hypothesis was that the anatomy of the AVN artery and the pattern of dominancy differ between subjects with and without RBBB. We retrospectively studied the coronary angiography of 92 patients with RBBB and 184 age- and gender-matched controls without RBBB. All the subjects had angiographically proven normal coronary arteries. The dominant circulation and precise origin of the AVN artery were determined in each subject. Obtained data were compared between the two study groups. There was no significant difference between the two groups in terms of dominancy (p value = 0.200). Origination of the AVN artery from the right circulatory system was more common in both groups, but this pattern was more prevalent in the cases than in the controls (p value = 0.021). There was a great variation of the AVN artery origin. In the total study population, the AVN artery was more commonly separated from a non crux origin than from the crux area. The prevalence of the non-crux origination of the AVN artery was significantly higher in the cases than in the controls (p value AVN artery from the right circulatory system was more common in both groups, the prevalence of the right origin of the AVN artery was significantly higher in the cases than in the controls. We observed that the AVN artery most commonly originated from the dominant artery but not necessarily from the crux. The anatomy of the AVN artery but not the pattern of dominancy is somewhat different in subjects with RBBB compared with normal individuals.

  2. Realistic Material Appearance Modelling

    Czech Academy of Sciences Publication Activity Database

    Haindl, Michal; Filip, Jiří; Hatka, Martin

    2010-01-01

    Roč. 2010, č. 81 (2010), s. 13-14 ISSN 0926-4981 R&D Projects: GA ČR GA102/08/0593 Institutional research plan: CEZ:AV0Z10750506 Keywords : bidirectional texture function * texture modelling Subject RIV: BD - Theory of Information http:// library .utia.cas.cz/separaty/2010/RO/haindl-realistic material appearance modelling.pdf

  3. The relation between coronary artery calcification in asymptomatic subjects and both traditional risk factors and living in the city centre

    DEFF Research Database (Denmark)

    Lambrechtsen, J; Gerke, Oke; Egstrup, Kenneth

    2012-01-01

    atherosclerosis. The relationship between CAC and several demographic and clinical parameters were evaluated using multivariate logistic regression. Results:  A total of 1225 individuals participated in the study, of whom 250 (20%) were living in the centres of major Danish cities. Gender and age showed......Objective:  To evaluate the association between the risk factor of living in the city centre as a surrogate for air pollution and the presence of coronary artery calcification (CAC) in a population of asymptomatic Danish subjects. Design and subjects:  A random sample of 1825 men and women...

  4. Dipyridamole dilates large cerebral arteries concomitant to headache induction in healthy subjects

    DEFF Research Database (Denmark)

    Kruuse, Christina; Jacobsen, T B; Lassen, L H

    2000-01-01

    Dipyridamole is used for secondary prophylaxis in ischemic stroke and as a vasodilator agent in myocardial scintigraphy. An important side effect to administering dipyridamole is headache. The aim of the current study was to investigate the effects of dipyridamole on cerebral blood flow, large ar...... causes a modest pCO2 independent dilatation of the MCA, which is time-linked to the onset, but not to the cessation, of headache....... a mean 5.6% +/- 6.7 (P = 0.005) relative increase of the arterial diameter. After dipyridamole the median peak headache score was 2 (range 0 to 7) compared with 0 (range 0 to 3) after placebo (P = 0.02). Dilatation of the middle cerebral artery outlasted the headache response. In conclusion, dipyridamole...

  5. Relation of coronary vasoreactivity and coronary calcification in asymptomatic subjects with a family history of premature coronary artery disease

    International Nuclear Information System (INIS)

    Pirich, Christian; Leber, Alexander; Knez, Andreas; Bengel, Frank M.; Nekolla, Stephan G.; Schwaiger, Markus; Haberl, Ralph

    2004-01-01

    Electron-beam computed tomography (EBCT) allows non-invasive imaging of coronary calcification and has been promoted as a screening tool for coronary artery disease (CAD) in asymptomatic high-risk subjects. This study assessed the relation of coronary calcifications to alterations in coronary vascular reactivity by means of positron emission tomography (PET) in asymptomatic subjects with a familial history of premature CAD. Twenty-one subjects (mean age 51±10 years) underwent EBCT imaging for coronary calcifications expressed as the coronary calcium score (CCS according to Agatston) and rest/adenosine-stress nitrogen-13 ammonia PET with quantification of myocardial blood flow (MBF) and coronary flow reserve (CFR). The mean CCS was 237±256 (median 146, range 0-915). The CCS was 100 units in 13. As defined by age-related thresholds, 15 subjects had an increased CCS (>75th percentile). Overall mean resting and stress MBF and CFR were 71±16 ml 100 g -1 min -1 , 218±54 ml 100 g -1 min -1 and 3.20±0.77, respectively. Three subjects with CCS ranging from 114 to 451 units had an abnormal CFR (<2.5). There was no relation between CCS and resting or stress MBF or CFR (r=0.17, 0.18 and 0.10, respectively). In asymptomatic subjects a pathological CCS was five times more prevalent than an abnormal CFR. The absence of any close relationship between CCS and CFR reflects the fact that quantitative myocardial perfusion imaging with PET characterises the dynamic process of vascular reactivity while EBCT is a measure of more stable calcified lesions in the arterial wall whose presence is closely related to age. (orig.)

  6. Hyperplastic Growth of Pulmonary Artery Smooth Muscle Cells from Subjects with Pulmonary Arterial Hypertension Is Activated through JNK and p38 MAPK.

    Directory of Open Access Journals (Sweden)

    Jamie L Wilson

    Full Text Available Smooth muscle in the pulmonary artery of PAH subjects, both idiopathic and hereditary, is characterized by hyperplasia. Smooth muscle cells (HPASMC isolated from subjects with or without PAH retain their in vivo phenotype as illustrated by their expression of alpha-smooth muscle actin and expression of H-caldesmon. Both non PAH and PAH HPASMC display a lengthy, approximately 94h, cell cycle. The HPASMC from both idiopathic and hereditary PAH display an abnormal proliferation characterized by continued growth under non-proliferative, non-growth stimulated conditions. This effector independent proliferation is JNK and p38 MAP kinase dependent. Blocking the activation of either abrogates the HPASMC growth. HPASMC from non PAH donors under quiescent conditions display negligible proliferation but divide upon exposure to growth factors such as PDGF-BB or FGF2 but not EGF. This growth does not involve the MAP kinases. Instead it routes via the tyrosine kinase receptor through mTOR and then 6SK. In the PAH cells PDGF-BB and FGF2 augment the dysregulated cell proliferation, also through mTOR/6SK. Additionally, blocking the activation of mTOR also modulates the MAP kinase promoted dysregulated growth. These results highlight key alterations in the growth of HPASMC from subjects with PAH which contribute to the etiology of the disease and can clearly be targeted at various regulatory points for future therapies.

  7. 3D Reconstruction of the Retinal Arterial Tree Using Subject-Specific Fundus Images

    Science.gov (United States)

    Liu, D.; Wood, N. B.; Xu, X. Y.; Witt, N.; Hughes, A. D.; Samcg, Thom

    Systemic diseases, such as hypertension and diabetes, are associated with changes in the retinal microvasculature. Although a number of studies have been performed on the quantitative assessment of the geometrical patterns of the retinal vasculature, previous work has been confined to 2 dimensional (2D) analyses. In this paper, we present an approach to obtain a 3D reconstruction of the retinal arteries from a pair of 2D retinal images acquired in vivo. A simple essential matrix based self-calibration approach was employed for the "fundus camera-eye" system. Vessel segmentation was performed using a semi-automatic approach and correspondence between points from different images was calculated. The results of 3D reconstruction show the centreline of retinal vessels and their 3D curvature clearly. Three-dimensional reconstruction of the retinal vessels is feasible and may be useful in future studies of the retinal vasculature in disease.

  8. Right ventricular ejection fraction during exercise in normal subjects and in coronary artery disease patients: assessment by multiple-gated equilibrium scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Maddahi, J.; Berman, D.S.; Matsuoka, D.T.; Waxman, A.D.; Forrester, J.S.; Swan, H.J.C.

    1980-07-01

    The response of right ventricular ejection fraction (RVEF) during exercise and its relationship to the location and extent of coronary artery disease are not fully understood. We have recently developed and validated a new method for scintigraphic evaluation of RVEF using rapid multiple-gated equilibrium scintigraphy and multiple right ventricular regions of interest. The technique has been applied during upright bicycle exercise in 10 normal subjects and 20 patients with coronary artery disease. Resting RVEF was not significantly different between the groups (0.49 +- 0.04 vs 0.47 +- 0.09, respectively, mean +- SD). In all 10 normal subjects RVEF rose (0.49 +- 0.04 to 0.66 +- 0.08, p < 0.01) at peak exercise. At peak exercise in coronary artery disease patients, the group RVEF remained unchanged (0.47 +- 0.09 to 0.50 +- 0.11, p = NS), but the individual responses varied. In the coronary artery disease patients, the relationship between RVEF response to exercise and exercise left ventricular function, septal motion and right coronary artery stenosis were studied. Significant statistical association was found only between exercise RVEF and right coronary artery stenosis. RVEF rose during exercise in seven of seven patients without right coronary artery stenosis (0.42 +- 0.06 to 0.58 +- 0.08, p = 0.001) and was unchanged or fell in 12 of 13 patients with right coronary artery stenosis (0.50 +- 0.09 to 0.45 +- 0.10, p = NS). We conclude that (1) in normal subjects RVEF increases during upright exercise and (2) although RVEF at rest is not necessarily affected by coronary artery disease, failure of RVEF to increase during exercise, in the absence of chronic obstructive pulmonary disease or valvular heart disease, may be related to the presence of significant right coronary artery stenosis.

  9. Right ventricular ejection fraction during exercise in normal subjects and in coronary artery disease patients: assessment by multiple-gated equilibrium scintigraphy

    International Nuclear Information System (INIS)

    Maddahi, J.; Berman, D.S.; Matsuoka, D.T.; Waxman, A.D.; Forrester, J.S.; Swan, H.J.C.

    1980-01-01

    The response of right ventricular ejection fraction (RVEF) during exercise and its relationship to the location and extent of coronary artery disease are not fully understood. We have recently developed and validated a new method for scintigraphic evaluation of RVEF using rapid multiple-gated equilibrium scintigraphy and multiple right ventricular regions of interest. The technique has been applied during upright bicycle exercise in 10 normal subjects and 20 patients with coronary artery disease. Resting RVEF was not significantly different between the groups (0.49 +- 0.04 vs 0.47 +- 0.09, respectively, mean +- SD). In all 10 normal subjects RVEF rose (0.49 +- 0.04 to 0.66 +- 0.08, p < 0.01) at peak exercise. At peak exercise in coronary artery disease patients, the group RVEF remained unchanged (0.47 +- 0.09 to 0.50 +- 0.11, p = NS), but the individual responses varied. In the coronary artery disease patients, the relationship between RVEF response to exercise and exercise left ventricular function, septal motion and right coronary artery stenosis were studied. Significant statistical association was found only between exercise RVEF and right coronary artery stenosis. RVEF rose during exercise in seven of seven patients without right coronary artery stenosis (0.42 +- 0.06 to 0.58 +- 0.08, p = 0.001) and was unchanged or fell in 12 of 13 patients with right coronary artery stenosis (0.50 +- 0.09 to 0.45 +- 0.10, p = NS). We conclude that (1) in normal subjects RVEF increases during upright exercise and (2) although RVEF at rest is not necessarily affected by coronary artery disease, failure of RVEF to increase during exercise, in the absence of chronic obstructive pulmonary disease or valvular heart disease, may be related to the presence of significant right coronary artery stenosis

  10. The Relationship Between Genetic Variations of the Cholesteryl Ester Transfer Protein Gene and Coronary Artery Disease in Turkish Subjects

    Science.gov (United States)

    Gundogdu, Fuat; Gurlertop, Yekta; Pirim, Ibrahim; Sevimli, Serdar; Dogan, Hasan; Arslan, Sakir; Aksoy, Hulya; Karakelloglu, Sule; Senocak, Huseyin

    2009-01-01

    Objective Although the relationship between cholesteryl ester transfer protein (CETP) and cholesterol metabolism has been characterized in recent years, the effect of CETP genetic variants associated with coronary artery disease (CAD) is still unclear. Therefore, we investigated the association between CETP gene polymorphism and levels of lipid in patients with CAD. Materials and Methods We conducted a case-control study that included 194 unrelated subjects who underwent coronary angiography for suspected ischemic heart disease. This group was divided into 96 patients with angiographically documented CAD and 98 subjects (individuals matched for age and gender) without angiographically documented CAD (CAD-free subjects), all of whom were studied to examine the genotypic distribution of the CETP gene polymorphism in CAD. Genotyping was performed via polymerase chain reaction. Results Of the 96 patients with CAD, 38 (40%) were B1B1, 42 (44%) B1B2 and 16 (16%) B2B2, compared with the control subjects, of which 35 (36%) were B1B1, 44 (45%) B1B2 and 19 (19%) B2B2. There were no significant differences between patients with CAD and control subjects in the distribution of the CETP gene polymorphism. Patients with the B1B1 genotype had lower high-density lipoprotein-cholesterol (HDL-C) and higher triglyceride (TG) levels than patients with the B2B2 genotype (p<0.05). In addition, among control subjects HDL-C levels were significantly higher in subjects with the B2B2 genotype than in subjects with the B1B1 genotype (p<0.01). Conclusion Our results suggest that genetic variations of the CTEP gene may be responsible for low HDL-C levels but may not be considered as a risk factor for CAD in the Turkish population. PMID:25610061

  11. Subjectivity

    Directory of Open Access Journals (Sweden)

    Jesús Vega Encabo

    2015-11-01

    Full Text Available In this paper, I claim that subjectivity is a way of being that is constituted through a set of practices in which the self is subject to the dangers of fictionalizing and plotting her life and self-image. I examine some ways of becoming subject through narratives and through theatrical performance before others. Through these practices, a real and active subjectivity is revealed, capable of self-knowledge and self-transformation. 

  12. Cardiovascular risk evaluation and prevalence of silent myocardial ischemia in subjects with asymptomatic carotid artery disease

    Directory of Open Access Journals (Sweden)

    Ciccone M

    2011-03-01

    Full Text Available Marco Matteo Ciccone1, Artor Niccoli-Asabella2, Pietro Scicchitano1, Michele Gesualdo1, Antonio Notaristefano2, Domenico Chieppa1, Santa Carbonara1, Gabriella Ricci1, Marco Sassara1, Corinna Altini2, Giovanni Quistelli1, Mario Erminio Lepera1, Stefano Favale1, Giuseppe Rubini21Cardiovascular Diseases Section, Department of Emergency and Organ Transplantation (DETO, 2Nuclear Medicine Unit, Department of Internal Medicine and of Public Medicine, University of Bari, Bari, ItalyIntroduction: Silent ischemia is an asymptomatic form of myocardial ischemia, not associated with angina or anginal equivalent symptoms, which can be demonstrated by changes in ECG, left ventricular function, myocardial perfusion, and metabolism. The aim of this study was to evaluate the prevalence of silent myocardial ischemia in a group of patients with asymptomatic carotid stenosis.Methods: A total of 37 patients with asymptomatic carotid plaques, without chest pain or dyspnea, was investigated. These patients were studied for age, sex, hypertension, diabetes, dyslipidemia, smoking, and family history of cardiac disease, and underwent technetium-99 m sestamibi myocardial stress-rest scintigraphy and echo-color Doppler examination of carotid arteries.Results: A statistically significant relationship (P = 0.023 was shown between positive responders and negative responders to scintigraphy test when both were tested for degree of stenosis. This relationship is surprising in view of the small number of patients in our sample. Individuals who had a positive scintigraphy test had a mean stenosis degree of 35% ± 7% compared with a mean of 44% ± 13% for those with a negative test. Specificity of our detection was 81%, with positive and negative predictive values of 60% and 63%, respectively.Conclusion: The present study confirms that carotid atherosclerosis is associated with coronary atherosclerosis and highlights the importance of screening for ischemic heart disease in

  13. Preproghrelin Leu72Met polymorphism in Chinese subjects with coronary artery disease and controls.

    Science.gov (United States)

    Tang, Na-Ping; Wang, Lian-Sheng; Yang, Li; Gu, Hai-Juan; Zhu, Huai-Jun; Zhou, Bo; Sun, Qing-Min; Cong, Ri-Hong; Wang, Bin

    2008-01-01

    Ghrelin, a novel endogenous ligand for the growth hormone secretagogue receptor, is considered to exert a protective effect against atherosclerosis. The Leu72Met (+408C>A) polymorphic variant of the preproghrelin, the gene for the ghrelin precursor, has been linked to obesity, diabetes and metabolic syndrome. However, it is unclear whether this polymorphism is associated with coronary artery disease (CAD). We conducted a case-control study with 317 CAD patients and 323 controls to investigate the potential association of the Leu72Met polymorphism with the occurrence of CAD and CAD-related phenotypes in Chinese population. No significant difference in the Leu72Met genotype frequency was observed between CAD patients and controls (P=NS). The Leu72Met polymorphism was not associated with hypertension, diabetes, dyslipidemia, the number of diseased vessels, plasma total cholesterol, triglyceride, high density lipoprotein cholesterol, low density lipoprotein cholesterol or fasting glucose levels in CAD patients. However, among CAD patients, those with variant genotypes (Leu72Met and Met72Met) had lower BMI (24.4+/-0.3 kg/m(2)) than Leu72Leu carriers (25.4+/-0.2 kg/m(2), adjusted P=0.033). Our data indicate that the preproghrelin Leu72Met polymorphism is not associated with CAD in Chinese population. However, the Leu72Met variant is associated with BMI among CAD patients.

  14. Factors associated with early atherosclerosis and arterial calcifications in young subjects with a benign phenotype of obesity.

    Science.gov (United States)

    Gilardini, Luisa; Pasqualinotto, Lucia; Di Matteo, Silvia; Caffetto, Katherine; Croci, Marina; Girola, Andrea; Invitti, Cecilia

    2011-08-01

    We assessed (i) the association between early arterial disease and factors linked to adiposity, dietary habits, and family in a young cohort of 151 obese children and adolescents with less than or equal to one cardiovascular (CV) risk factor, (ii) whether in subjects with carotid calcifications there was an imbalance of calcium-phosphorus homeostasis. Measurement included: carotid ultrasound, oral glucose tolerance test, anthropometry, body composition, dietary history, white blood cells count, lipids, uric acid, adiponectin, insulin, C-reactive protein, plasminogen activator inhibitor 1 (PAI-1), 25-hydroxyvitamin D, parathyroid hormone (PTH), calcium and phosphorus. Obese children with carotid artery intima media thickness (cIMT) values >75° percentile (0.55 mm), compared to those with lower cIMT, were more obese, more often pubertal and had higher prevalence of family history of CV disease (CVD) (P < 0.05), higher plasma PAI-1 and uric acid (P < 0.001) and lower adiponectin (P < 0.05) and high-density lipoprotein (HDL) cholesterol levels (P < 0.05). After adjustment for sex, age, puberty, obesity, and insulin levels, only PAI-I remained significantly different between the two groups (10.9 (7.2-29.8) vs. 6.2 (4.3-10.6) ng/ml, P < 0.001). Dietary intake did not affect cIMT values. Eight percent of subjects showed nonatherosclerotic carotid calcifications with patchy pattern. These children had a worse lipid profile (P < 0.05) and higher plasma PTH levels (48.6 ± 21.5 vs 38.5 ± 16.9 pg/ml, P < 0.05) that were inversely associated with 25-hydroxyvitamin D levels (r = 0.245, P < 0.01). Present results suggest that (i) several adiposity-related factors may play a role in promoting the development of early arterial diseases in young subjects with a benign phenotype of obesity, (ii) a PTH rise resulting from a subclinical imbalance in calcium-phosphorus homeostasis may affect the biological process of vascular calcifications.

  15. Determining carotid artery pressure from scaled diameter waveforms: comparison and validation of calibration techniques in 2026 subjects

    International Nuclear Information System (INIS)

    Vermeersch, S J; Verdonck, P R; Segers, P; Rietzschel, E R; De Buyzere, M L; Gillebert, T C; De Bacquer, D; De Backer, G; Van Bortel, L M

    2008-01-01

    Calibrated diameter distension waveforms could provide an alternative for local arterial pressure assessment more widely applicable than applanation tonometry. We compared linearly and exponentially calibrated carotid diameter waveforms to tonometry readings. Local carotid pressures measured by tonometry and diameter waveforms measured by ultrasound were obtained in 2026 subjects participating in the Asklepios study protocol. Diameter waveforms were calibrated using a linear and an exponential calibration scheme and compared to measured tonometry waveforms by examining the mean root-mean-squared error (RMSE), carotid systolic blood pressure (SBP car ) and augmentation index (AIx) of calibrated and measured pressures. Mean RMSE was 5.2(3.3) mmHg (mean(stdev)) for linear and 4.6(3.6) mmHg for exponential calibration. Linear calibration yielded an underestimation of SBP car by 6.4(4.1) mmHg which was strongly correlated to values of brachial pulse pressure (PP bra ) (R = 0.4, P car by 1.9(3.9) mmHg, independent of PP bra . AIx was overestimated by linear calibration by 1.9(10.1)%, the difference significantly increasing with increasing AIx (R = 0.25, P < 0.001) and by exponential calibration by 5.4(10.6)%, independently of the value of AIx. Properly calibrated diameter waveforms offer a viable alternative for local pressure estimation at the carotid artery. Compared to linear calibration, exponential calibration significantly improves the pressure estimation

  16. Arterial stiffness estimation in healthy subjects: a validation of oscillometric (Arteriograph) and tonometric (SphygmoCor) techniques.

    Science.gov (United States)

    Ring, Margareta; Eriksson, Maria Jolanta; Zierath, Juleen Rae; Caidahl, Kenneth

    2014-11-01

    Arterial stiffness is an important cardiovascular risk marker, which can be measured noninvasively with different techniques. To validate such techniques in healthy subjects, we compared the recently introduced oscillometric Arteriograph (AG) technique with the tonometric SphygmoCor (SC) method and their associations with carotid ultrasound measures and traditional risk indicators. Sixty-three healthy subjects aged 20-69 (mean 48 ± 15) years were included. We measured aortic pulse wave velocity (PWVao) and augmentation index (AIx) by AG and SC, and with SC also the PWVao standardized to 80% of the direct distance between carotid and femoral sites (St-PWVaoSC). The carotid strain, stiffness index and intima-media thickness (cIMTmean) were evaluated by ultrasound. PWVaoAG (8.00 ± 2.16 m s(-1)) was higher (Pstiffness indices by AG and SC correlate with vascular risk markers in healthy subjects. AIxao results by AG and SC are closely interrelated, but higher values are obtained by AG. In the lower range, PWVao values by AG and SC are similar, but differ for higher values. Our results imply the necessity to apply one and the same technique for repeated studies.

  17. Realistic intake of a flavanol-rich soluble cocoa product increases HDL-cholesterol without inducing anthropometric changes in healthy and moderately hypercholesterolemic subjects.

    Science.gov (United States)

    Martínez-López, Sara; Sarriá, Beatriz; Sierra-Cinos, José Luis; Goya, Luis; Mateos, Raquel; Bravo, Laura

    2014-02-01

    To assess whether antioxidant, anti-inflammatory and other cardio-protective effects attributed to cocoa are achieved when regularly consuming moderate amounts of a flavanol-rich soluble cocoa product, a non-randomized, controlled, crossover, free-living study was carried out in healthy (n = 24; 25.9 ± 5.6 years) and moderately hypercholesterolemic (200-240 mg dL(-1); n = 20; 30.0 ± 10.3 years) volunteers. Participants consumed two servings per day (7.5 g per serving) of a soluble cocoa product (providing 45.3 mg flavanols per day) in milk, which was compared with consuming only milk during a 4 week period. The effects on systolic and diastolic blood pressure and heart rate were determined, as well as on serum lipid and lipoprotein profiles, interleukins (IL)-1β, IL-6, IL-8, IL-10, tumor necrosis factor-α (TNF-α), monocyte chemoattractant protein-1 (MCP-1), vascular (VCAM-1) and intercellular cell adhesion molecules (ICAM-1), serum malondialdehyde (MDA), carbonyl groups (CG), ferric reducing/antioxidant power (FRAP), oxygen radical absorbance capacity (ORAC), and free radical scavenging capacity (ABTS). During the study, the volunteers' diets and physical activity were also evaluated, as well as any changes in weight, skin folds, circumferences and related anthropometric parameters. Cocoa and certain polyphenol-rich fruits and vegetables and their derivatives were restricted. After consuming the cocoa product positive effects were observed such as an increase in serum HDL-C (p related biomarkers and anthropometric parameters were unaffected. We have therefore concluded that regular consumption of this cocoa product in a Spanish-Mediterranean diet may protect against cardiovascular disease in healthy and hypercholesterolemic subjects without producing any weight gain or other anthropometric changes.

  18. Effects of the Mediterranean diet and exercise in subjects with coronary artery disease.

    Science.gov (United States)

    Noites, Andreia; Pinto, Joana; Freitas, Carla Patrícia; Melo, Cristina; Albuquerque, Aníbal; Teixeira, Madalena; Mesquita Bastos, José

    2015-11-01

    The association of the Mediterranean diet and exercise appears to have a protective role, reducing cardiovascular risk. This study investigated the effects of education sessions on the Mediterranean diet and an exercise program in modifying eating behaviors, body composition and abdominal fat. An experimental study was performed on 20 subjects with known coronary heart disease randomly assigned to experimental (n=10) and control (n=10) groups. Both groups received education sessions on the Mediterranean diet, but the experimental group also followed an eight-week program of specific exercises. A semiquantitative food frequency questionnaire was administered to analyze food intake, bioimpedance was used to measure weight, fat mass and lean mass, and waist circumference was measured to calculate waist-to-height ratio. After eight weeks, protein (pdiet reduced carbohydrate and saturated fat intake, reflected in reduced fat mass. The association of the exercise program showed additional benefits in reduction of protein and cholesterol intake and abdominal fat. Copyright © 2015 Sociedade Portuguesa de Cardiologia. Published by Elsevier España. All rights reserved.

  19. Changes in medical treatment six months after risk stratification with HeartScore and coronary artery calcification scanning of healthy middle-aged subjects

    DEFF Research Database (Denmark)

    Sørensen, Mette Hjortdal; Gerke, Oke; Lambrechtsen, Jess

    2012-01-01

    Objectives: The aim was to examine and compare the impact of HeartScore and coronary artery calcification (CAC) score on subsequent changes in the use of medication. Methods: A total of 1156 healthy men and women, aged 50 or 60, had a baseline medical examination and a coronary artery CT-scan as ......Objectives: The aim was to examine and compare the impact of HeartScore and coronary artery calcification (CAC) score on subsequent changes in the use of medication. Methods: A total of 1156 healthy men and women, aged 50 or 60, had a baseline medical examination and a coronary artery CT......-up questionnaires addressing current medication were mailed to the participants. Results: A completed questionnaire was returned by 1075 (93%) subjects. At follow up, the overall use of prophylactic medication was significantly increased. Of those with CAC (n = 462) or high HeartScore (n = 233), 21 and 19...

  20. Central obesity and survival in subjects with coronary artery disease: a systematic review of the literature and collaborative analysis with individual subject data

    DEFF Research Database (Denmark)

    Coutinho, Thais; Goel, Kashish; Corrêa de Sá, Daniel

    2011-01-01

    The aim of this study was to examine the association of central (waist circumference [WC] and waist-hip ratio [WHR]) and total obesity (body mass index [BMI]) measures with mortality in coronary artery disease (CAD) patients.......The aim of this study was to examine the association of central (waist circumference [WC] and waist-hip ratio [WHR]) and total obesity (body mass index [BMI]) measures with mortality in coronary artery disease (CAD) patients....

  1. Clinical study on relationship of visualization of the cerebral arteries in MR angiography to age, sex, laterality or lacunar infarction in neurologically normal subjects

    International Nuclear Information System (INIS)

    Kajiya, Yoriko

    1995-01-01

    The purpose of this study is to assess the correlation between the visualization of cerebral peripheral arteries in magnetic resonance angiography (MRA) and aging, sex, laterality or lacunar infarctions in magnetic resonance imaging (MRI). Two hundred forty-four neurologically normal subjects (119 males and 125 females, aged 7 to 82 yrs.) were evaluated with MRA and MRI. A three-dimensional Fourier transformation (3DFT-TOF) pulse sequence with slab thickness of 115 mm was used to obtain axial, sagittal and coronal projection images. The imaging parameters were 30/11/1 (TR/TE/excitations) using a 20 degree flip angle and the voxel size was 0.9 x 1.1 x 0.9 mm. A total of 6 arteries including bilateral anterior cerebral arteries (ACAs), middle cerebral arteries (MCAs) and posterior cerebral arteries (PCAs) for every subject were each graded into 8 scores by the degree of visualization of the arteries. Asymptomatic lacunar infarctions were analyzed in subjects of fifties or more. They were scored as 0-2 based on their size and the scores were summed. An age-related decline of visualization of the cerebral arteries was observed in ACA (r=-0.603, p<0.001), MCA (r=-0.452, p<0.001) and PCA (r=-0.537, p<0.001). Females during the fifth decade had a higher score of visualization of the arteries than males (p<0.01). No substantial relationship was observed between visualization of the arteries and sex in other decades, laterality or lacunar infarctions. The MRA using a 3DFT-TOF pulse sequence with slab thickness of 115 mm disclosed an age-related decline of visualization of the cerebral arteries and a sex-dependent difference of the visualization in the fifth decade probably due to the decline of the blood flow velocity with aging and a difference in it between females and males in the fifth decade, respectively. (J.P.N.)

  2. Clinical study on relationship of visualization of the cerebral arteries in MR angiography to age, sex, laterality or lacunar infarction in neurologically normal subjects

    Energy Technology Data Exchange (ETDEWEB)

    Kajiya, Yoriko [Kagoshima Univ. (Japan). Faculty of Medicine

    1995-08-01

    The purpose of this study is to assess the correlation between the visualization of cerebral peripheral arteries in magnetic resonance angiography (MRA) and aging, sex, laterality or lacunar infarctions in magnetic resonance imaging (MRI). Two hundred forty-four neurologically normal subjects (119 males and 125 females, aged 7 to 82 yrs.) were evaluated with MRA and MRI. A three-dimensional Fourier transformation (3DFT-TOF) pulse sequence with slab thickness of 115 mm was used to obtain axial, sagittal and coronal projection images. The imaging parameters were 30/11/1 (TR/TE/excitations) using a 20 degree flip angle and the voxel size was 0.9 x 1.1 x 0.9 mm. A total of 6 arteries including bilateral anterior cerebral arteries (ACAs), middle cerebral arteries (MCAs) and posterior cerebral arteries (PCAs) for every subject were each graded into 8 scores by the degree of visualization of the arteries. Asymptomatic lacunar infarctions were analyzed in subjects of fifties or more. They were scored as 0-2 based on their size and the scores were summed. An age-related decline of visualization of the cerebral arteries was observed in ACA (r=-0.603, p<0.001), MCA (r=-0.452, p<0.001) and PCA (r=-0.537, p<0.001). Females during the fifth decade had a higher score of visualization of the arteries than males (p<0.01). No substantial relationship was observed between visualization of the arteries and sex in other decades, laterality or lacunar infarctions. The MRA using a 3DFT-TOF pulse sequence with slab thickness of 115 mm disclosed an age-related decline of visualization of the cerebral arteries and a sex-dependent difference of the visualization in the fifth decade probably due to the decline of the blood flow velocity with aging and a difference in it between females and males in the fifth decade, respectively. (J.P.N.).

  3. Defining Anatomic Variants of the Coronary Artery in Taiwanese Subjects Using 64-Multidetector-Row Computed Tomography

    Directory of Open Access Journals (Sweden)

    Hung-Jung Wang

    2007-10-01

    Full Text Available The newly developed 64-multidetector-row computed tomography (MDCT prompted us to evaluate coronary angiography using this noninvasive method. We reviewed 281 images of MDCT coronary angiography in Taiwanese. The origins of the coronary arteries were identified from the luminal aspect of the aorta. We described them as seen from the aortic sinus looking toward the cardiac ventricle. The sinus facing the left ventricle was designated sinus 1, and that facing the right ventricle was designated sinus 2. Anatomic variants of the coronary artery were divided into five types according to the structure of the left anterior descending artery, right coronary artery, and left circumflex artery. Of the 281 patients, 275 (97.9% had the type I variant in which the right coronary artery originated from sinus 2. MDCT provides advantages in defining anatomic variation and helps in the planning of clinical therapy or surgery.

  4. Combined aerobic and resistance exercise training decreases peripheral but not central artery wall thickness in subjects with type 2 diabetes.

    NARCIS (Netherlands)

    Schreuder, T.H.A.; Munckhof, I.C.L. van den; Poelkens, F.; Hopman, M.T.; Thijssen, D.H.

    2015-01-01

    OBJECTIVE: Little is known about the impact of exercise training on conduit artery wall thickness in type 2 diabetes. We examined the local and systemic impact of exercise training on superficial femoral (SFA), brachial (BA), and carotid artery (CA) wall thickness in type 2 diabetes patients and

  5. Genetic risk analysis of coronary artery disease in Pakistani subjects using a genetic risk score of 21 variants.

    Science.gov (United States)

    Shahid, Saleem Ullah; Shabana; Cooper, Jackie A; Beaney, Katherine E; Li, Kawah; Rehman, Abdul; Humphries, Steve E

    2017-03-01

    Conventional coronary artery disease (CAD) risk factors like age, gender, blood lipids, hypertension and smoking have been the basis of CAD risk prediction algorithms, but provide only modest discrimination. Genetic risk score (GRS) may provide improved discrimination over and above conventional risk factors. Here we analyzed the genetic risk of CAD in subjects from Pakistan, using a GRS of 21 variants in 18 genes and examined whether the GRS is associated with blood lipid levels. 625 (405 cases and 220 controls) subjects were genotyped for variants, NOS3 rs1799983, SMAD3 rs17228212, APOB rs1042031, LPA rs3798220, LPA rs10455872, SORT1 rs646776, APOE rs429358, GLUL rs10911021, FTO rs9939609, MIA3 rs17465637, CDKN2Ars10757274, DAB2IP rs7025486, CXCL12 rs1746048, ACE rs4341, APOA5 rs662799, CETP rs708272, MRAS rs9818870, LPL rs328, LPL rs1801177, PCSK9 rs11591147 and APOE rs7412 by TaqMan and KASPar allele discrimination techniques. Individually, the single SNPs were not associated with CAD except APOB rs1042031 and FTO rs993969 (p = 0.01 and 0.009 respectively). However, the combined GRS of 21 SNPs was significantly higher in cases than controls (19.37 ± 2.56 vs. 18.47 ± 2.45, p = 2.9 × 10 -5 ), and compared to the bottom quintile, CAD risk in the top quintile of the GRS was 2.96 (95% CI 1.71-5.13). Atherogenic blood lipids showed significant positive association with GRS. The GRS was quantitatively associated with CAD risk and showed association with blood lipid levels, suggesting that the mechanism of these variants is likely to be, in part at least, through creating an atherogenic lipid profile in subjects carrying high numbers of risk alleles. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Quantitative evaluation of the structure and function of the common carotid artery in hypertriglyceridemic subjects using ultrasound radiofrequency-data technology

    International Nuclear Information System (INIS)

    Dan, Hai-Jun; Wang, Yan; Sha, Hai-Jing; Wen, Shu-Bin

    2012-01-01

    Assessment of the properties of blood-vessel walls by ultrasound radiofrequency (RF)-data technology is an innovative technique. We quantitatively evaluated the intima-media thickness (IMT) and arterial elasticity of the common carotid artery (CCA) in asymptomatic subjects with hypertriglyceridemia (HTG) using RF-data technology. Thirty HTG subjects and 30 matched controls were enrolled in the study. The common carotid arterial systolic diameter, diastolic diameter, IMT, carotid distensibility (CD), local pulse wave velocity (PWVβ), and stiffness (β) were compared between the two groups, as was the correlation between triglyceride level and the parameters mentioned above. The HTG group had significantly higher values of CCA-IMT compared with the control group (p 0.05). The level of triglycerides had significant positive correlations with CCA-IMT (r = 0.493, p < 0.001), whereas significant correlations with CD, PWVβ, and β were not observed in the HTG group. Ultrasound RF-data technology can be used to non-invasively and quantitatively detect the change in the structure and function of the CCA in asymptomatic HTG subjects for evaluating preclinical atherosclerosis.

  7. Investigation of dynamic SPECT measurements of the arterial input function in human subjects using simulation, phantom and human studies

    Science.gov (United States)

    Winant, Celeste D.; Aparici, Carina Mari; Zelnik, Yuval R.; Reutter, Bryan W.; Sitek, Arkadiusz; Bacharach, Stephen L.; Gullberg, Grant T.

    2012-01-01

    Computer simulations, a phantom study and a human study were performed to determine whether a slowly rotating single-photon computed emission tomography (SPECT) system could provide accurate arterial input functions for quantification of myocardial perfusion imaging using kinetic models. The errors induced by data inconsistency associated with imaging with slow camera rotation during tracer injection were evaluated with an approach called SPECT/P (dynamic SPECT from positron emission tomography (PET)) and SPECT/D (dynamic SPECT from database of SPECT phantom projections). SPECT/P simulated SPECT-like dynamic projections using reprojections of reconstructed dynamic 94Tc-methoxyisobutylisonitrile (94Tc-MIBI) PET images acquired in three human subjects (1 min infusion). This approach was used to evaluate the accuracy of estimating myocardial wash-in rate parameters K1 for rotation speeds providing 180° of projection data every 27 or 54 s. Blood input and myocardium tissue time-activity curves (TACs) were estimated using spatiotemporal splines. These were fit to a one-compartment perfusion model to obtain wash-in rate parameters K1. For the second method (SPECT/D), an anthropomorphic cardiac torso phantom was used to create real SPECT dynamic projection data of a tracer distribution derived from 94Tc-MIBI PET scans in the blood pool, myocardium, liver and background. This method introduced attenuation, collimation and scatter into the modeling of dynamic SPECT projections. Both approaches were used to evaluate the accuracy of estimating myocardial wash-in parameters for rotation speeds providing 180° of projection data every 27 and 54 s. Dynamic cardiac SPECT was also performed in a human subject at rest using a hybrid SPECT/CT scanner. Dynamic measurements of 99mTc-tetrofosmin in the myocardium were obtained using an infusion time of 2 min. Blood input, myocardium tissue and liver TACs were estimated using the same spatiotemporal splines. The spatiotemporal maximum

  8. Investigation of dynamic SPECT measurements of the arterial input function in human subjects using simulation, phantom and human studies

    International Nuclear Information System (INIS)

    Winant, Celeste D; Aparici, Carina Mari; Bacharach, Stephen L; Gullberg, Grant T; Zelnik, Yuval R; Reutter, Bryan W; Sitek, Arkadiusz

    2012-01-01

    Computer simulations, a phantom study and a human study were performed to determine whether a slowly rotating single-photon computed emission tomography (SPECT) system could provide accurate arterial input functions for quantification of myocardial perfusion imaging using kinetic models. The errors induced by data inconsistency associated with imaging with slow camera rotation during tracer injection were evaluated with an approach called SPECT/P (dynamic SPECT from positron emission tomography (PET)) and SPECT/D (dynamic SPECT from database of SPECT phantom projections). SPECT/P simulated SPECT-like dynamic projections using reprojections of reconstructed dynamic 94 Tc-methoxyisobutylisonitrile ( 94 Tc-MIBI) PET images acquired in three human subjects (1 min infusion). This approach was used to evaluate the accuracy of estimating myocardial wash-in rate parameters K 1 for rotation speeds providing 180° of projection data every 27 or 54 s. Blood input and myocardium tissue time-activity curves (TACs) were estimated using spatiotemporal splines. These were fit to a one-compartment perfusion model to obtain wash-in rate parameters K 1 . For the second method (SPECT/D), an anthropomorphic cardiac torso phantom was used to create real SPECT dynamic projection data of a tracer distribution derived from 94 Tc-MIBI PET scans in the blood pool, myocardium, liver and background. This method introduced attenuation, collimation and scatter into the modeling of dynamic SPECT projections. Both approaches were used to evaluate the accuracy of estimating myocardial wash-in parameters for rotation speeds providing 180° of projection data every 27 and 54 s. Dynamic cardiac SPECT was also performed in a human subject at rest using a hybrid SPECT/CT scanner. Dynamic measurements of 99m Tc-tetrofosmin in the myocardium were obtained using an infusion time of 2 min. Blood input, myocardium tissue and liver TACs were estimated using the same spatiotemporal splines. The spatiotemporal

  9. Relations between a novel, reliable, and rapid index of arterial compliance (PP-HDI) and well-established inidices of arterial blood pressure (ABP) in a sample of hypertensive elderly subjects.

    Science.gov (United States)

    Bergamini, L; Finelli, M E; Bendini, C; Ferrari, E; Veschi, M; Neviani, F; Manni, B; Pelosi, A; Rioli, G; Neri, M

    2009-01-01

    Hypertension is a risk factor for a long-lasting arterial wall-remodelling leading to stiffness. The rapid method measuring the pulse pressure (PP) by means of the tool of Hypertension Diagnostic Instruments (HDI) called PP-HDI, overcomes some of the problems arising with more-time consuming methods, like ambulatory blood pressure monitoring (ABPM), and give information about the elasticity of the arterial walls. We studied the relationship between the PP-HDI, the large artery compliance (LA-C) and small artery compliance (SA-C) and few well-established indices of arterial blood pressure (ABP) in a sample of 75 hypertensive subjects, aged 65 years and over. Significant correlations between LA-C and heart rate (HR), PP-ABPM and PP-HDI were found. SA-C relates with HR and systolic blood pressure (SBP) measured in lying and standing positions. Applying a stepwise regression analysis, we found that LA-C variance stems from PP-HDI and HR, while SA-C variance stems from SBP in lying position. Receiver operator characteristic (ROC) curves for thresholds of PP showed that PP-HDI reached levels of sensitivity/specificity similar to PP-ABPM. In conclusion, surveillance of ABP through hemo-dynamic indices, in particular of SBP, is essential, nevertheless the advantage of this control is not known in an elderly population where the organ damage is already evident. PP needs necessarily an instrumental measurement. The PP-HDI result is similar in reliability with respect to PPABPM, but is more rapid and well applicable in an elderly population.

  10. The prognostic value of coronary endothelial and microvascular dysfunction in subjects with normal or non-obstructive coronary artery disease

    DEFF Research Database (Denmark)

    Brainin, Philip; Frestad, Daria; Prescott, Eva

    2018-01-01

    AIMS: Coronary vascular dysfunction is linked with poor cardiovascular prognosis in patients without obstructive coronary artery disease (CAD) but a critical appraisal of the literature is lacking. METHODS AND RESULTS: We performed a systematic review and meta-analysis to quantify...

  11. Acute and chronic effects of flavanol-rich cocoa on vascular function in subjects with coronary artery disease: a randomized double-blind placebo-controlled study.

    Science.gov (United States)

    Farouque, H M Omar; Leung, Michael; Hope, Sarah A; Baldi, Mauro; Schechter, Clyde; Cameron, James D; Meredith, Ian T

    2006-07-01

    Evidence suggests that flavonoid-containing diets reduce cardiovascular risk, but the mechanisms responsible are unclear. In the present study, we sought to determine the effect of flavanol-rich cocoa on vascular function in individuals with CAD (coronary artery disease). Forty subjects (61+/-8 years; 30 male) with CAD were recruited to a 6-week randomized double-blind placebo-controlled study. Subjects consumed either a flavanol-rich chocolate bar and cocoa beverage daily (total flavanols, 444 mg/day) or matching isocaloric placebos daily (total flavanols, 19.6 mg/day) for 6 weeks. Brachial artery FMD (flow-mediated dilation) and SAC (systemic arterial compliance) were assessed at baseline, 90 min following the first beverage and after 3 and 6 weeks of daily consumption. Soluble cellular adhesion molecules and FBF (forearm blood flow) responses to ACh (acetylcholine chloride; 3-30 microg/min) and SNP (sodium nitroprusside; 0.3-3 microg/min) infusions, forearm ischaemia and isotonic forearm exercise were assessed at baseline and after 6 weeks. FMD, SAC and FBF responses did not differ between groups at baseline. No acute or chronic changes in FMD or SAC were seen in either group. No difference in soluble cellular adhesion molecules, FBF responses to ischaemia, exercise, SNP or ACh was seen in the group receiving flavanol-rich cocoa between baseline and 6 weeks. These data suggest that over a 6-week period, flavanol-rich cocoa does not modify vascular function in patients with established CAD.

  12. Vertebral artery variations and osseous anomaly at the C1-2 level diagnosed by 3D CT angiography in normal subjects

    Energy Technology Data Exchange (ETDEWEB)

    Wakao, Norimitsu; Kamiya, Mitsuhiro [Aichi Medical University, Department of Spine Center, Aichi (Japan); Aichi Medical University, Department of Orthopedic Surgery, Nagakute, Aichi (Japan); Takeuchi, Mikinobu; Hirasawa, Atsuhiko; Kawanami, Katsuhisa; Takayasu, Masakazu [Aichi Medical University, Department of Spine Center, Aichi (Japan); Nishimura, Manabu [Aichi Medical University, Department of Radiology, Nagakute, Aichi (Japan); Riew, K.D. [Washington University, Department of Orthopedic Surgery, St. Louis, MO (United States); Imagama, Shiro [Nagoya University, Department of Orthopedic Surgery, Nagoya, Aichi (Japan); Sato, Keiji [Aichi Medical University, Department of Orthopedic Surgery, Nagakute, Aichi (Japan)

    2014-10-15

    The craniovertebral junction is anatomically complicated. Representative vertebral artery (VA) variations include the persistent first intersegmental artery (FIA), fenestration of the VA above and below C1 (FEN), posterior inferior cerebellar artery (PICA) from C1/2, and high-riding VA (HRVA). The ponticulus posticus (PP) is a well-known osseous anomaly at C1. Although those anomalies are frequent in patients with cervical deformity, the prevalence of these in subjects with normal cervical spines is still unknown. The aim of this study is to investigate the variations and prevalence of vascular and osseous anomalies based on three-dimensional computed tomographic (3D CT) angiography in patients without any cervical diseases, such as rheumatoid arthritis, Klippel-Feil syndrome, or Down syndrome. Eligible subjects were patients who underwent 3D CT angiography by the Department of Otorhinolaryngology and Internal Medicine from January 2009 to October 2013 in our institution. The authors defined a HRVA as a C2 pedicle with a maximum diameter of 4 mm or less. Among 480 subjects with a mean age of 63.1 years, 387 patients were eligible. One hundred and eighteen subjects were female, and 269 were male. HRVA was observed in 10.1 % of patients (39 out of 387 cases), FIA in 1.8 % (7 cases), FEN in 1.3 % (5 cases), and PICA in 1.3 % (5 cases). PP was observed in 6.2 % of patients (24 cases). According to past reports, many VA anomalies could be attributed to congenital or acquired conditions (e.g., rheumatoid arthritis). However, VA anomalies appear to exist even in patients without any such cervical diseases. (orig.)

  13. Kuhn: Realist or Antirealist?

    Directory of Open Access Journals (Sweden)

    Michel Ghins

    1998-06-01

    Full Text Available Although Kuhn is much more an antirealist than a realist, the earlier and later articulations of realist and antirealist ingredients in his views merit close scrutiny. What are the constituents of the real invariant World posited by Kuhn and its relation to the mutable paradigm-related worlds? Various proposed solutions to this problem (dubbed the "new-world problem" by Ian Hacking are examined and shown to be unsatisfactory. In The Structure of Scientific Revolutions, the stable World can reasonably be taken to be made up of ordinary perceived objects, whereas in Kuhn's later works the transparadigmatic World is identified with something akin to the Kantian world-in-itself. It is argued that both proposals are beset with insuperable difficulties which render Kuhn's earlier and later versions of antirealism implausible.

  14. Noninvasive detection of coronary artery wall thickening with age in healthy subjects using high resolution MRI with beat-to-beat respiratory motion correction.

    Science.gov (United States)

    Scott, Andrew D; Keegan, Jennifer; Mohiaddin, Raad H; Firmin, David N

    2011-10-01

    To demonstrate coronary artery wall thickening with age in a small healthy cohort using a highly efficient, reliable, and reproducible high-resolution MR technique. A 3D cross-sectional MR vessel wall images (0.7 × 0.7 × 3 mm resolution) with retrospective beat-to-beat respiratory motion correction (B2B-RMC) were obtained in the proximal right coronary artery of 21 healthy subjects (age, 22-62 years) with no known cardiovascular disease. Lumen and outer wall (lumen + vessel wall) areas were measured in one central slice from each subject and average wall thickness and wall area/outer wall area ratio (W/OW) calculated. Imaging was successful in 18 (86%) subjects with average respiratory efficiency 99.3 ± 1.7%. Coronary vessel wall thickness and W/OW significantly correlate with subject age, increasing by 0.088 mm and 0.031 per decade respectively (R = 0.53, P = 0.024 and R = 0.48, P = 0.046). No relationship was found between lumen area and vessel wall thickness (P = NS), but outer wall area increased significantly with vessel wall thickness at 19 mm(2) per mm (P = 0.046). This is consistent with outward vessel wall remodeling. Despite the small size of our healthy cohort, using high-resolution MR imaging and B2B-RMC, we have demonstrated increasing coronary vessel wall thickness and W/OW with age. The results obtained are consistent with outward vessel wall remodeling. Copyright © 2011 Wiley-Liss, Inc.

  15. Noncontrast-enhanced magnetic resonance renal angiography using a repetitive artery and venous labelling technique at 3 T: comparison with contrast-enhanced magnetic resonance angiography in subjects with normal renal function

    Energy Technology Data Exchange (ETDEWEB)

    Park, Sung Yoon [Sungkyunkwan University School of Medicine, Department of Radiology and Center for Imaging Science, Samsung Medical Center, Seoul (Korea, Republic of); Severance Hospital, Yonsei University College of Medicine, Department of Radiology and Research Institute of Radiological Science, Seoul (Korea, Republic of); Kim, Chan Kyo; Park, Byung Kwan [Sungkyunkwan University School of Medicine, Department of Radiology and Center for Imaging Science, Samsung Medical Center, Seoul (Korea, Republic of); Kim, EunJu [Philips Healthcare Korea, Seoul (Korea, Republic of)

    2014-09-13

    To investigate the feasibility of noncontrast-enhanced MR angiography (NC-MRA) using the repetitive artery and venous labelling (RAVEL) technique to evaluate renal arteries compared to contrast-enhanced MR angiography (CE-MRA). Twenty-five subjects with normal renal function underwent NC-MRA using a RAVEL technique and CE-MRA at 3 T. Two independent readers analysed the MRA images. Image quality, number of renal arteries, presence or absence of an early branching vessel, and diameter of the main renal arteries were evaluated. The overall image quality of NC-MRA was fair or greater in 88 % of right and 92 % of left renal arteries, while it was 96 % in both sides with CE-MRA. On NC-MRA, the number of renal arteries in all subjects was perfectly predicted by both readers. Sensitivity and specificity for predicting early branching vessels were 82 % and 100 % for reader 1 and 82 % and 95 % for reader 2. Inter-modality agreement for comparing the diameters of main renal arteries was good or excellent at all segments for both readers. Inter-reader agreement was moderate or good at all segments except at the right distal segment on NC-MRA. NC-MRA with the RAVEL technique at 3 T may have comparable diagnostic feasibility for evaluating renal arteries compared to CE-MRA. (orig.)

  16. Noncontrast-enhanced magnetic resonance renal angiography using a repetitive artery and venous labelling technique at 3 T: comparison with contrast-enhanced magnetic resonance angiography in subjects with normal renal function.

    Science.gov (United States)

    Park, Sung Yoon; Kim, Chan Kyo; Kim, EunJu; Park, Byung Kwan

    2015-02-01

    To investigate the feasibility of noncontrast-enhanced MR angiography (NC-MRA) using the repetitive artery and venous labelling (RAVEL) technique to evaluate renal arteries compared to contrast-enhanced MR angiography (CE-MRA). Twenty-five subjects with normal renal function underwent NC-MRA using a RAVEL technique and CE-MRA at 3 T. Two independent readers analysed the MRA images. Image quality, number of renal arteries, presence or absence of an early branching vessel, and diameter of the main renal arteries were evaluated. The overall image quality of NC-MRA was fair or greater in 88% of right and 92% of left renal arteries, while it was 96% in both sides with CE-MRA. On NC-MRA, the number of renal arteries in all subjects was perfectly predicted by both readers. Sensitivity and specificity for predicting early branching vessels were 82% and 100% for reader 1 and 82% and 95% for reader 2. Inter-modality agreement for comparing the diameters of main renal arteries was good or excellent at all segments for both readers. Inter-reader agreement was moderate or good at all segments except at the right distal segment on NC-MRA. NC-MRA with the RAVEL technique at 3 T may have comparable diagnostic feasibility for evaluating renal arteries compared to CE-MRA. • Accurate pre-treatment evaluation of renal artery anatomy helps clinical decision-making. • NC-MRA using RAVEL offers acceptable imaging quality for renal artery evaluation. • The 3 T RAVEL technique provides excellent diagnostic performance for renal artery evaluation. • The 3 T RAVEL technique may be an alternative to contrast-enhanced MRA.

  17. Getting realistic; Endstation Demut

    Energy Technology Data Exchange (ETDEWEB)

    Meyer, J.P.

    2004-01-28

    The fuel cell hype of the turn of the millenium has reached its end. The industry is getting realistic. If at all, fuel cell systems for private single-family and multiple dwellings will not be available until the next decade. With a Europe-wide field test, Vaillant intends to advance the PEM technology. [German] Der Brennstoffzellen-Hype der Jahrtausendwende ist verfolgen. Die Branche uebt sich in Bescheidenheit. Die Marktreife der Systeme fuer Ein- und Mehrfamilienhaeuser wird - wenn ueberhaupt - wohl erst im naechsten Jahrzehnt erreicht sein. Vaillant will durch einen europaweiten Feldtest die Entwicklung der PEM-Technologie vorantreiben. (orig.)

  18. Application of cine cardiac MR imaging in normal subjects and patients with valvular, coronary artery, and aortic disease

    International Nuclear Information System (INIS)

    Maddahi, J.; Ostrzega, E.; Crues, J.; Honma, H.; Siegel, R.; Charuzi, Y.; Berman, D.

    1987-01-01

    Cine MR imaging was performed on 15 normal subjects and 27 patients with cardiac disease. In normal subjects, high signal intensity of flowing blood contrasted with that of the myocardium. In 16 patients with valvular regurgitation, signal void jet due to turbulence was visualized across the diseased valves. In three IHSS patients, thickened LV myocardium, mitral regurgitant jets, and systolic LV outflow jets were noted. Five patients with myocardial infarction (MI) showed thinning and/or hypokinesis of MI regions. In three patients with Marfan syndrome, aortic dilatation, insufficiency, and flap (one pt) were identified. Cine MR imaging is potentially useful for evaluation of a variety of cardiac diseases

  19. Increased risk of coronary artery calcification progression in subjects with high baseline Lp(a) levels: The Kangbuk Samsung Health Study.

    Science.gov (United States)

    Cho, Jung Hwan; Lee, Da Young; Lee, Eun Seo; Kim, Jihyun; Park, Se Eun; Park, Cheol-Young; Lee, Won-Young; Oh, Ki-Won; Park, Sung-Woo; Rhee, Eun-Jung

    2016-11-01

    Results from previous studies support the association of lipoprotein(a) [Lp(a)] levels and coronary artery disease risk. In this study, we analyzed the association between baseline Lp(a) levels and future progression of coronary artery calcification (CAC) in apparently healthy Korean adults. A total of 2611 participants (mean age: 41years, 92% mend) who underwent a routine health check-up in 2010 and 2014 were enrolled. Coronary artery calcium score (CACS) were measured by multi-detector computed tomography. Baseline Lp(a) was measured by high-sensitivity immunoturbidimetric assay. Progression of CAC was defined as a change in CACS >0 over four years. Bivariate correlation analyses with baseline Lp(a) and other metabolic parameters revealed age, total cholesterol, HDL-C, LDL-C and CACS to have a significant positive correlation, while body weight, fasting glucose level, blood pressure and triglyceride level were negatively correlated with baseline Lp(a) level. After four years of follow-up, 635 subjects (24.3%) had CAC progression. The participants who had CAC progression were older, composed of more men, more obese, and had higher fasting glucose levels and worse baseline lipid profiles compared to those who did not have CAC progression. The mean serum Lp(a) level was significantly higher in subjects who had CAC progression compared to those who did not (32.5 vs. 28.9mg/dL, p<0.01). When the risk for CAC progression according to baseline Lp(a) was calculated, those with Lp(a) level≥50mg/dL had an odds ratio of 1.333 (95% CI 1.027-1.730) for CAC progression compared to those with Lp(a)<50mg/dL after adjusting for confounding factors. In this study, the subjects who had higher Lp(a) were at significantly higher risk for CAC progression after four years of follow-up, suggesting the role of high Lp(a) in CAC progression. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  20. High-sensitivity C-reactive protein and exercise-induced changes in subjects suspected of coronary artery disease

    DEFF Research Database (Denmark)

    Mouridsen, Mette Rauhe; Nielsen, Olav Wendelboe; Carlsen, Christian Malchau

    2014-01-01

    stenosis (n=41), compared with non-CAD-subjects (n=114), 2.93 mg/L (interquartile range 1.03-5.06 mg/L) and 1.30 mg/L (interquartile range 0.76-2.74 mg/L), respectively, P=0.007. In multivariate analyses testing conventional risk factors, hs-CRP proved borderline significant, odds ratio =2.32, P=0....... An increase in hs-CRP of 0.13 mg/L (interquartile range 0.05-0.24 mg/L) from baseline to 5 minutes after peak exercise was found (P

  1. Increased Risk of Progression of Coronary Artery Calcification in Male Subjects with High Baseline Waist-to-Height Ratio: The Kangbuk Samsung Health Study.

    Science.gov (United States)

    Oh, Hyung Geun; Nallamshetty, Shriram; Rhee, Eun Jung

    2016-02-01

    The waist-to-height ratio (WHtR) is an easy and inexpensive adiposity index that reflects central obesity. In this study, we examined the association of baseline WHtR and progression of coronary artery calcification (CAC) over 4 years of follow-up in apparently healthy Korean men. A total of 1,048 male participants (mean age, 40.9 years) in a health-screening program in Kangbuk Samsung Hospital, Seoul, Korea who repeated a medical check-up in 2010 and 2014 were recruited. Baseline WHtR was calculated using the value for the waist in 2010 divided by the value for height in 2010. The CAC score (CACS) of each subject was measured by multi-detector computed tomography in both 2010 and 2014. Progression of CAC was defined as a CACS change over 4 years greater than 0. During the follow-up period, progression of CAC occurred in 278 subjects (26.5%). The subjects with CAC progression had slightly higher but significant baseline WHtR compared to those who did not show CAC progression (0.51±0.04 vs. 0.50±0.04, P<0.01). The proportion of subjects with CAC progression significantly increased as the baseline WHtR increased from the 1st quartile to 4th quartile groups (18.3%, 18.7%, 28.8%, and 34.2%; P<0.01). The risk for CAC progression was elevated with an odds ratio of 1.602 in the 4th quartile group of baseline WHtR even after adjustment for confounding variables (95% confidence interval, 1.040 to 2.466). Increased baseline WHtR was associated with increased risk for CAC progression. WHtR might be a useful screening tool to identify individuals at high risk for subclinical atherosclerosis.

  2. Composition of plasma and atheromatous plaque among coronary artery disease subjects consuming coconut oil or sunflower oil as the cooking medium.

    Science.gov (United States)

    Palazhy, Sabitha; Kamath, Prakash; Rajesh, P C; Vaidyanathan, Kannan; Nair, Shiv K; Vasudevan, D M

    2012-12-01

    Coconut oil, which is rich in medium-chain saturated fatty acids, is the principal cooking medium of the people of Kerala, India. Replacement of saturated fat with polyunsaturated fat is effective in reducing serum cholesterol levels. However, the effect of substituting coconut oil with sunflower oil on the fatty acid composition of plaque has not been thoroughly investigated. We therefore evaluated and compared the fatty acid composition of plasma and plaque among subjects consuming coconut oil or sunflower oil as the cooking medium. Endarterectomy samples and plasma samples were obtained from subjects who underwent coronary artery bypass grafts (n = 71). The subjects were grouped based on the type of oil they were using as their cooking medium (coconut oil or sunflower oil). The fatty acid composition in the plaques and the plasma was determined by HPLC and the data were analyzed statistically. Sunflower oil consumers had elevated concentrations of linoleic acid (p = 0.001) in plasma, while coconut oil users had higher myristic acid levels (p = 0.011) in plasma. Medium-chain fatty acids did not differ significantly between the two groups in the plasma. Medium-chain fatty acids were detected in the plaques in both groups of subjects. In contrast to previous reports, long-chain saturated fatty acids dominated the lipid content of plaque in this population, and the fatty acid composition of plaque was not significantly different between the two groups. No correlation between fatty acids of plasma and plaque was observed in either group. A change in cooking medium, although it altered the plasma fatty acid composition, was not reflected in the plaque composition.

  3. Triglyceride glucose index, a marker of insulin resistance, is associated with coronary artery stenosis in asymptomatic subjects with type 2 diabetes.

    Science.gov (United States)

    Lee, Eun Young; Yang, Hae Kyung; Lee, Joonyub; Kang, Borami; Yang, Yeoree; Lee, Seung-Hwan; Ko, Seung-Hyun; Ahn, Yu-Bae; Cha, Bong Yun; Yoon, Kun-Ho; Cho, Jae Hyoung

    2016-09-15

    Insulin resistance is one of the most important contributing factors to cardiovascular disease. This study aimed to investigate the association between coronary artery stenosis (CAS) and triglyceride glucose index (TyG index), a simple insulin resistance marker, in asymptomatic subjects with type 2 diabetes. We recruited asymptomatic adults with type 2 diabetes but without previous history of coronary heart disease (n = 888). Significant CAS was defined as maximum intraluminal stenosis ≥70 % by coronary CT angiography. TyG index was calculated as log [fasting triglycerides (mg/dl) x fasting glucose (mg/dl)/2]. Mean age was 63.8 ± 9.5 and 58.9 % of the subjects were men. We analyzed the participants according to the tertile of TyG index. The TyG index was correlated with HOMA-IR (r = 0.397, P index were younger but showed worse clinical and metabolic parameters. The prevalence of CAS was higher in subjects with higher tertile of TyG compared with those with lower tertile of TyG (14 % vs. 7.8 %, P = 0.022). On multiple regression analysis, the highest tertile of TyG index was an independent risk factor for CAS after adjustment for other confounders (odds ratio, 3.19 [95 % CI, 1.371-7.424]). Subgroup analysis showed that TyG index showed more significant association with CAS in patients with risk factors such as old age, longer duration of diabetes, poor glycemic control, no statin use, and male gender. Higher TyG index is associated with increased risk of CAS in asymptomatic subjects with type 2 diabetes, particularly when they have risk factors for cardiovascular disease. This study was retrospectively registered in ClinicalTrials. gov with the registration number of NCT02070926 in Feb 23, 2014.

  4. Blood Pressure Is the Determinant for the Increased Risk for Intracranial Arterial Stenosis in Subjects with Elevated Glycated Hemoglobin Levels: The Kangbuk Samsung Health Study.

    Science.gov (United States)

    Oh, Hyung-Geun; Rhee, Eun-Jung

    2016-11-01

    Ischemic stroke is known to be an important vascular complication of diabetes. Intracranial arterial stenosis (ICAS) is considered as an important cause of stroke in Asians. We aimed to analyze the risk for ICAS assessed by transcranial Doppler (TCD) ultrasonography in different groups of young Korean subjects divided by glycated hemoglobin (HbA1c) levels. This study included 10,437 participants without history of cardiovascular diseases (81.3% men, mean age 43 years) from a health screening program, in whom TCD ultrasonography was used to detect greater than 50% ICAS based on criteria modified from the SONIA (Stroke Outcomes and Neuroimaging of Intracranial Atherosclerosis) trial. The subjects were divided into 3 groups according to HbA1c levels: HbA1c < 5.7%, 5.7 ≤ HbA1c < 6.5%, and HbA1c ≥ 6.5% or under medication for diabetes. Among the participants, 3.0% of the subjects had ICAS. The subjects with ICAS tended to have higher mean HbA1c level compared with those without ICAS (5.8 ± .8 versus 5.7 ± .6, P = .063). The proportion of subjects with ICAS significantly increased as the HbA1c increased from the first to the third group (2.8%, 3.0%, 4.6%, P for linear trend = .022). In logistic regression analysis with ICAS as the dependent variable, the group with HbA1c ≥ 6.5% showed significantly increased odds ratio for ICAS with subjects with HbA1c < 5.7% as the reference after adjustment for confounding variables (1.575, 95% confidence interval 1.056-2.347). However, this significance disappeared with inclusion of presence of hypertension in the model. The risk for ICAS assessed by TCD was increased in young Korean subjects with HbA1c ≥ 6.5%. However, this significance was attenuated after adjustment for presence of hypertension, suggesting the importance of hypertension in ICAS. Copyright © 2016 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  5. The effect of opium addiction on serum adiponectin and leptin levels in male subjects: a case control study from Kerman Coronary Artery Disease Risk Factors Study (KERCADRS).

    Science.gov (United States)

    Shahouzehi, Beydolah; Shokoohi, Mostafa; Najafipour, Hamid

    2013-01-01

    Serum adiponectin and leptin levels have been shown to be related to obesity, insulin resistance and cardiovascular diseases (CVD). Opium addiction has a positive association with endocrine system disorders. The relationship between adipokines and opium addiction is unclear. In the present study, we aimed to determine serum adiponectin and leptin levels in opium addicted subjects. 176 men, 88 opium addicts and 88 non- addicts were randomly selected from subjects who participated in Kerman Coronary Artery Disease Risk factors Study (KERCADRS); a population-based study. Serum adiponectin and leptin levels were measured using ELISA and compared between two groups. We adjusted the effect of some confounding factors such as the patients' demographic, clinical and medical history in multivariate analysis model. The serum level of adiponectin in opium addicts was significantly lower than control group (6.5±3.6 vs. 9.8±8.1 µg/ml, Popium addicts, p = 0.80). In the multivariate analysis, after adjusting for age, cigarette smoking, body mass index, type 2 diabetes, hypertension, cholesterol, triglyceride and high and low density lipoproteins, the negative association between opium addiction and decreased adiponectin level was still present (β = -0.144, P value = 0.005). The results showed that opium addiction reduces serum adiponectin level. Since adiponectin has been shown to have anti-diabetic and anti-atherogenic effects, its reduction may account for increase in the risk of metabolic disorders such as insulin resistance and CVD amongst opium addicted patients.

  6. Dietary Fats and Oxidative Stress: A Cross-Sectional Study Among Coronary Artery Disease Subjects Consuming Coconut Oil/Sunflower Oil.

    Science.gov (United States)

    Palazhy, Sabitha; Kamath, Prakash; Vasudevan, D M

    2018-01-01

    Coconut oil has been used by the people of Kerala as a cooking medium for several decades. Due to its alleged hypercholesterolemic activity, general population in recent times is shifting to cooking oils rich in polyunsaturated fats, the most popular being sunflower oil. The effect of long-term consumption of sunflower oil on oxidative stress in humans is not well investigated. We studied oxidative stress among coronary artery disease (CAD) patients who were consuming coconut oil or sunflower oil as a part of their routine diet. Men, aged 35-70 years, with established CAD, who presented to the hospital for routine cardiac evaluations, were enrolled in this observational study. Group 1 and 2 consisted of 73 and 80 subjects consuming coconut oil and sunflower oil respectively for over a period of 2 years. Lipid profile and parameters for oxidative stress were evaluated among them. Conventional lipid parameters did not differ significantly between the two groups. Mean vitamin C concentration was significantly reduced for subjects on sunflower oil compared to those consuming coconut oil ( P  = 0.044). Malondialdehyde was higher for sunflower oil consumers compared to coconut oil consumers ( P  coconut oil did not induce hypercholesterolemia compared to sunflower oil. On the other hand, sunflower oil group had elevated oxidative stress compared to coconut oil group.

  7. Triangulating and guarding realistic polygons

    NARCIS (Netherlands)

    Aloupis, G.; Bose, P.; Dujmovic, V.; Gray, C.M.; Langerman, S.; Speckmann, B.

    2014-01-01

    We propose a new model of realistic input: k-guardable objects. An object is k-guardable if its boundary can be seen by k guards. We show that k-guardable polygons generalize two previously identified classes of realistic input. Following this, we give two simple algorithms for triangulating

  8. C-Peptide Is Independently Associated with an Increased Risk of Coronary Artery Disease in T2DM Subjects: A Cross-Sectional Study.

    Directory of Open Access Journals (Sweden)

    Lingshu Wang

    Full Text Available C-peptide has been reported to be a marker of subclinical atherosclerosis in type 2 diabetes mellitus (T2DM patients, whereas its role in coronary artery disease (CAD has not been clarified, especially in diabetics with differing body mass indices (BMIs.This cross-sectional study included 501 patients with T2DM. First, all subjects were divided into the following two groups: CAD and non-CAD. Then, binary logistic regression was used to determine the risk factors for CAD for all patients. To clarify the role of obesity, we re-divided all subjects into two additional groups (obese and non-obese based on BMI. Finally, binary logistic regression was used to determine the risk factors for CAD for each weight group.The patients with CAD showed a higher BMI and fasting C-peptide level in addition to an increased prevalence of traditional risk factors for CAD, such as hypertension, insulin resistance, higher cholesterol, cysteine-C (Cys-C and lower estimated glomerular filtration rate (eGFR. Logistic regression analysis showed that fasting C-peptide (OR=1.513, p=0.005, insulin treatment (OR=1.832, p=0.027 hypertension (OR=1.987, p=0.016 and hyperlipidemia (OR=4.159, p<0.001 significantly increased the risk of clinical CAD in the T2DM patients independent of age, gender, diabetes duration, smoking and alcohol statuses, fasting insulin and glucose, hypoglycemic episodes, UA and eGFR. Additionally, in both of the obese (OR=1.488, p=0.049 and non-obese (OR=1.686, p=0.037 DM groups, C-peptide was associated with an increased risk of CAD after multiple adjustments.C-peptide is associated with an increased CAD risk in T2DM patients, no matter whether they are obese or not.

  9. Realistic Visualization of Virtual Views

    DEFF Research Database (Denmark)

    Livatino, Salvatore

    2005-01-01

    that can be impractical and sometime impossible. In addition, the artificial nature of data often makes visualized virtual scenarios not realistic enough. Not realistic in the sense that a synthetic scene is easy to discriminate visually from a natural scene. A new field of research has consequently...... developed and received much attention in recent years: Realistic Virtual View Synthesis. The main goal is a high fidelity representation of virtual scenarios while easing modeling and physical phenomena simulation. In particular, realism is achieved by the transfer to the novel view of all the physical...... phenomena captured in the reference photographs, (i.e. the transfer of photographic-realism). An overview of most prominent approaches in realistic virtual view synthesis will be presented and briefly discussed. Applications of proposed methods to visual survey, virtual cinematography, as well as mobile...

  10. Generating realistic images using Kray

    Science.gov (United States)

    Tanski, Grzegorz

    2004-07-01

    Kray is an application for creating realistic images. It is written in C++ programming language, has a text-based interface, solves global illumination problem using techniques such as radiosity, path tracing and photon mapping.

  11. Association of low baseline free thyroxin levels with progression of coronary artery calcification over 4 years in euthyroid subjects: the Kangbuk Samsung Health Study.

    Science.gov (United States)

    Park, Hye-Jeong; Kim, Jihyun; Han, Eun Jin; Park, Se Eun; Park, Cheol-Young; Lee, Won-Young; Oh, Ki-Won; Park, Sung-Woo; Rhee, Eun-Jung

    2016-06-01

    Overt and subclinical hypothyroidism are risk factors for atherosclerosis and cardiovascular diseases. It is unclear whether thyroid hormone levels within the normal range are also associated with atherosclerosis measured by coronary artery calcium (CAC). This study aimed to examine the relationship between normal variations in thyroid function and changes in CAC. We conducted a 4-year retrospective study of 2173 apparently healthy men and women with normal thyroid hormone levels. Their free thyroxin (FT4), free triiodothyronin (FT3) and thyroid-stimulating hormone (TSH) levels were measured by electrochemiluminescent immunoassay. The CAC score (CACS) of each subject was measured by multidetector computed tomography in both 2010 and 2014. Progression of CAC was defined as a CACS change over 4 years > 0. The mean CACS changes over 4 years by quartiles of baseline FT4 level (lowest to highest) were 12·9, 8·43, 7·82 and 7·81 (P = 0·028). CAC progression was not significantly associated with either the baseline FT3 or TSH levels. The odds ratios (OR) for CAC progression over 4 years (highest vs lowest quartile for baseline FT4) were 0·647 (95% confidence interval (CI) 0·472-0·886) after adjustment for confounding factor, which were attenuated with further adjustment for lipid profiles, homoeostasis model assessment of insulin resistance, high-sensitivity C-reactive protein and hypertension [0·747 (95% CI 0·537-1·038)]. Quartiles of baseline FT3 or TSH level did not show any increased OR for CAC progression after adjustment for confounding factors. In this cohort of euthyroid men and women, a low baseline FT4 level was associated with a high risk of CACS progression over 4 years. © 2015 John Wiley & Sons Ltd.

  12. Comparison of tomographic coronary artery calcification index (calcium score) and ultrasonographic measurement of intima-media complex thickness in diabetic subjects

    International Nuclear Information System (INIS)

    Wolski, Cyprian; Rotkiewicz, Arkadiusz; Grzelak, Piotr; Elgalal, Marcin; Stefańczyk, Ludomir

    2011-01-01

    At present, there is a number of diagnostic imaging procedures allowing for the evaluation of atherosclerosis. The earliest, subclinical stage of atherosclerosis can be visualized with the development of computed tomography (CT) and ultrasound (US) techniques. Therefore, the purpose of this study was to assess the degree of coronary artery calcification and carotid intima-media thickness in diabetic subjects divided into different age groups. Fifty-six men, aged from 18 to 72 were included in the study. Participants were divided into 4 groups according to age (18–30, 31–45, 46–60 and more than 60 years). Two tests were performed: coronary calcium score (CS) determination and intima-media thickness (IMT) in ultrasound. CS was performed using a multi-slice scanner. Images were analyzed using the Agatson method. Ultrasound examinations were performed using a 9–12-MHz linear transducer. The correlation coefficient between calcium score index (CSI) and age of patients was 0.52 (p<0.001). The correlation between duration of diabetes and CSI was significantly lower (r=0.3; p<0.05). The increase of IMT is associated with age to a much greater extent and the correlation coefficient was 0.63 (p<0.001). IMT depended on the duration of diabetes, but the correlation was also weak (r=0.35; p<0.01). Comparison of the findings obtained in the presented study and in the group of healthy subjects proves that influence of diabetes on vascular deterioration may be observed, even among young individuals. Obtained results allow to make the following conclusions: 1. Calcium score index remains low in the group of male patients with diabetes before the age of 45. 2. Intima-media thickness correlates well with age (r=0.6; p<0.05) and weaker with the duration of diabetes (r=0.35; p<0.05). 3. IMT assessment may be a useful tool to identify the increased predisposition to atherosclerosis, also before the age of 30

  13. Any realistic theory must be computationally realistic: a response to N. Gisin's definition of a Realistic Physics Theory

    OpenAIRE

    Bolotin, Arkady

    2014-01-01

    It is argued that the recent definition of a realistic physics theory by N. Gisin cannot be considered comprehensive unless it is supplemented with requirement that any realistic theory must be computationally realistic as well.

  14. Use of a Novel Abdominal Aortic and Junctional Tourniquet to Reduce or Eliminate Flow in the Brachial and Popliteal Arteries in Human Subjects.

    Science.gov (United States)

    Lyon, Matthew; Johnson, Daniel; Gordon, Richard

    2015-01-01

    Penetrating injuries of the proximal large arteries are a common cause of death on the battlefield due to rapid exsanguination. Applying an effective tourniquet to stop bleeding at the axillary and proximal femoral arteries (junctional sites) is difficult. Prior studies have shown that the Abdominal Aortic and Junctional Tourniquet (AAJT) effectively reduced blood flow in the common femoral artery with application of the device around the lower abdomen. Our objective was to determine the effectiveness of the AAJT to stop blood flow in the proximal femoral artery (PFA), and the axillary artery (AA). This was a prospective observational trial using human volunteers. The AAJT consists of a wedge-shaped bladder and integrated strap. The bladder has an integrated manometer, which is used to measure the pressure in the bladder. For the AA, the AAJT was placed over the axillary junction at the anterior axillary line with the strap placed across the contralateral shoulder. For the PFA, the AAJT bladder was placed over the right groin with the strap positioned across both femoral trochanters. Spectral Doppler measurements were taken of the PFA and AA at baseline and as the bladder was inflated. Collected data included pressure of the AAJT.

  15. Progress in realistic LOCA analysis

    Energy Technology Data Exchange (ETDEWEB)

    Young, M Y; Bajorek, S M; Ohkawa, K [Westinghouse Electric Corporation, Pittsburgh, PA (United States)

    1994-12-31

    While LOCA is a complex transient to simulate, the state of art in thermal hydraulics has advanced sufficiently to allow its realistic prediction and application of advanced methods to actual reactor design as demonstrated by methodology described in this paper 6 refs, 5 figs, 3 tabs

  16. Time management: a realistic approach.

    Science.gov (United States)

    Jackson, Valerie P

    2009-06-01

    Realistic time management and organization plans can improve productivity and the quality of life. However, these skills can be difficult to develop and maintain. The key elements of time management are goals, organization, delegation, and relaxation. The author addresses each of these components and provides suggestions for successful time management.

  17. Triangulating and guarding realistic polygons

    NARCIS (Netherlands)

    Aloupis, G.; Bose, P.; Dujmovic, V.; Gray, C.M.; Langerman, S.; Speckmann, B.

    2008-01-01

    We propose a new model of realistic input: k-guardable objects. An object is k-guardable if its boundary can be seen by k guards in the interior of the object. In this abstract, we describe a simple algorithm for triangulating k-guardable polygons. Our algorithm, which is easily implementable, takes

  18. Should scientific realists be platonists?

    DEFF Research Database (Denmark)

    Busch, Jacob; Morrison, Joe

    2015-01-01

    an appropriate use of the resources of Scientific Realism (in particular, IBE) to achieve platonism? (§2) We argue that just because a variety of different inferential strategies can be employed by Scientific Realists does not mean that ontological conclusions concerning which things we should be Scientific...

  19. In vivo 3D modeling of the femoropopliteal artery in human subjects based on x-ray angiography: Methodology and validation

    International Nuclear Information System (INIS)

    Klein, Andrew J.; Casserly, Ivan P.; Messenger, John C.; Carroll, John D.; Chen, S.-Y. James

    2009-01-01

    Endovascular revascularization of the femoropopliteal (FP) artery has been limited by high rates of restenosis and stent fracture. The unique physical forces that are applied to the FP artery during leg movement have been implicated in these phenomena. The foundation for measuring the effects of physical forces on the FP artery in a clinically relevant environment is based on the ability to develop 3D models of this vessel in different leg positions in vivo in patients with peripheral arterial disease (PAD). By acquiring paired angiographic images of the FP artery, and using angiography-based 3D modeling algorithms previously validated in the coronary arteries, the authors generated 3D models of ten FP arteries in nine patients with PAD with the lower extremity in straight leg (SL) and crossed leg (CL) positions. Due to the length of the FP artery, overlapping paired angiographic images of the entire FP artery were required to image the entire vessel, which necessitated the development of a novel fusion process in order to generate a 3D model of the entire FP artery. The methodology of angiographic acquisition and 3D model generation of the FP artery is described. In a subset of patients, a third angiographic view (i.e., validation view) was acquired in addition to the standard paired views for the purpose of validating the 3D modeling process. The mean root-mean-square (rms) error of the point-to-point distances between the centerline of the main FP artery from the 2D validation view and the centerline from the 3D model placed in the validation view for the SL and CL positions were 0.93±0.19 mm and 1.12±0.25 mm, respectively. Similarly, the mean rms error of the same comparison for the main FP artery and sidebranches for the SL and CL positions were 1.09±0.38 mm and 1.21±0.25 mm, respectively. A separate validation of the novel fusion process was performed by comparing the 3D model of the FP artery derived from fusion of 3D models of adjacent FP segments with

  20. Effect of ST36 Acupuncture on Hyperventilation-Induced CO2 Reactivity of the Basilar and Middle Cerebral Arteries and Heart Rate Variability in Normal Subjects

    Directory of Open Access Journals (Sweden)

    Sang-Ho Hyun

    2014-01-01

    Full Text Available This study was conducted to verify the effect of acupuncture on cerebral haemodynamics to provide evidence for the use of acupuncture treatment as a complementary therapy for the high-risk stroke population. The effect of ST36 acupuncture treatment on the hyperventilation-induced CO2 reactivity of the basilar and middle cerebral arteries was studied in 10 healthy male volunteers (mean age, 25.2 ± 1.5 years using a transcranial Doppler sonography with an interval of 1 week between measurements, and a portable ECG monitoring system was used to obtain ECG data simultaneously. The CO2 reactivity of the basilar and middle cerebral arteries increased significantly after ST36 acupuncture treatment, whereas the mean arterial blood pressure and pulse rate did not change significantly. The high-frequency power significantly increased after ST36 acupuncture treatment, and the percentage increase of high-frequency power correlated significantly with the percentage increase in the CO2 reactivity of the contralateral middle cerebral artery. These data suggest that ST36 acupuncture treatment increases CO2 reactivity, indicating improvement of vasodilatory potential of the cerebral vasculature to compensate for fluctuations caused by changes in external conditions. The increase in parasympathetic tone by ST36 acupuncture treatment is responsible for this therapeutic effect.

  1. Realistic rhetoric and legal decision

    Directory of Open Access Journals (Sweden)

    João Maurício Adeodato

    2017-06-01

    Full Text Available The text aims to lay the foundations of a realistic rhetoric, from the descriptive perspective of how the legal decision actually takes place, without normative considerations. Aristotle's rhetorical idealism and its later prestige reduced rhetoric to the art of persuasion, eliminating important elements of sophistry, especially with regard to legal decision. It concludes with a rhetorical perspective of judicial activism in complex societies.

  2. Simple and Realistic Data Generation

    DEFF Research Database (Denmark)

    Pedersen, Kenneth Houkjær; Torp, Kristian; Wind, Rico

    2006-01-01

    This paper presents a generic, DBMS independent, and highly extensible relational data generation tool. The tool can efficiently generate realistic test data for OLTP, OLAP, and data streaming applications. The tool uses a graph model to direct the data generation. This model makes it very simple...... to generate data even for large database schemas with complex inter- and intra table relationships. The model also makes it possible to generate data with very accurate characteristics....

  3. Realist cinema as world cinema

    OpenAIRE

    Nagib, Lucia

    2017-01-01

    The idea that “realism” is the common denominator across the vast range of productions normally labelled as “world cinema” is widespread and seemly uncontroversial. Leaving aside oppositional binaries that define world cinema as the other of Hollywood or of classical cinema, this chapter will test the realist premise by locating it in the mode of production. It will define this mode as an ethics that engages filmmakers, at cinema’s creative peaks, with the physical and historical environment,...

  4. Association Between the 20210G>A Prothrombin Gene Polymorphism and Arterial Ischemic Stroke in Children and Young Adults-Two Meta-analyses of 3586 Cases and 6440 Control Subjects in Total.

    Science.gov (United States)

    Sarecka-Hujar, Beata; Kopyta, Ilona; Skrzypek, Michal; Sordyl, Joanna

    2017-04-01

    Previous data have shown that the 20210G>A polymorphism of the Factor II gene is related to an increased prothrombin level, which may in turn lead to a procoagulant state. The heterogeneous and multifactorial character of arterial ischemic stroke often results in contradictory reports describing the association between the 20210G>A polymorphism and arterial ischemic stroke in different populations. We performed a meta-analysis of available data addressing the relation between the FII 20210G>A polymorphism and arterial ischemic stroke, both in young adults and children. We searched PubMed using appropriate keywords. The inclusion criteria for the study were as follows: case-control study, study population consisting of children, study population consisting of young adults, arterial ischemic stroke confirmed by magnetic resonance imaging or computed tomography, and English language. The exclusion criteria included lack of genotype or allele frequencies, study design other than a case-control study, outcome definition other than arterial ischemic stroke, and previously overlapped patient groups. Finally, 30 case-control studies (14 in children and 16 in young adults) were included. Statistical analyses were conducted using R software. Heterogeneity between the studies was evaluated using the Dersimonian and Laird's Q test. In the case of significant between-studies heterogeneity, the pooled odds ratio was estimated with a random-effects model, otherwise a fixed-effects model was used. The pooled analysis showed that carriers of 20210A allele (GA+AA genotypes) of the prothrombin gene are more common in arterial ischemic stroke patients, both in children and young adults, than in control subjects (P = 0.006; odds ratio, 1.83; 95% confidence interval, 1.19 to 2.80 and P = 0.001; odds ratio, 1.69; 95% confidence interval, 1.25 to 2.28, respectively). The results of the present meta-analysis have proven that the FII 20210G>A polymorphism is associated with arterial

  5. Foot reflexology can increase vagal modulation, decrease sympathetic modulation, and lower blood pressure in healthy subjects and patients with coronary artery disease.

    Science.gov (United States)

    Lu, Wan-An; Chen, Gau-Yang; Kuo, Cheng-Deng

    2011-01-01

    Complementary and alternative medicine (CAM) has long been used by people to postpone the aging process and to reverse disease progression. Reflexology is a CAM method that involves massage to reflex areas in the feet and hands. This study investigated the effect of foot reflexology (FR) on the autonomic nervous modulation in patients with coronary artery disease (CAD) by using heart rate variability analysis. Seventeen people with angiographically patent coronary arteries and 20 patients with CAD scheduled for coronary artery bypass graft surgery were recruited as the control and CAD groups, respectively. The normalized high-frequency power (nHFP) was used as the index of vagal modulation and the normalized very low-frequency power (nVLFP) as the index of vagal withdrawal and renin-angiotensin modulation. In both control and CAD groups, the nHFP was increased significantly whereas the nVLFP was decreased significantly 30 and 60 minutes after FR, as compared with those before FR. The systolic, diastolic, mean arterial, and pulse pressures were significantly decreased after FR in both groups of participants. In the CAD group, the percentage change in heart rate 30 and 60 minutes after FR was smaller than that in the control, and the percentage change in nVLFP 60 minutes after FR was smaller than that in the control. In conclusion, a higher vagal modulation, lower sympathetic modulation, and lower blood pressure can be observed following 60 minutes of FR in both controls and CAD patients. The magnitude of change in the autonomic nervous modulation in CAD patients was slightly smaller than that in the controls. FR may be used as an efficient adjunct to the therapeutic regimen to increase the vagal modulation and decrease blood pressure in both healthy people and CAD patients.

  6. Liver cirrhosis and arterial hypertension

    DEFF Research Database (Denmark)

    Henriksen, Jens Henrik; Møller, Søren

    2006-01-01

    blood pressure. This review considers the alterations in systemic hemodynamics in patients with cirrhosis in relation to essential hypertension and arterial hypertension of the renal origin. Subjects with arterial hypertension (essential, secondary) may become normotensive during the development...... of cirrhosis, and arterial hypertension is rarely manifested in patients with cirrhosis, even in cases with renovascular disease and high circulating renin activity. There is much dispute as to the understanding of homoeostatic regulation in cirrhotic patients with manifest arterial hypertension. This most...

  7. Skin perfusion pressure measured with a photo sensor in an air-filled plastic balloon: validity and reproducibility on the lower leg in normal subjects and patients suspected of obliterative arterial disease

    DEFF Research Database (Denmark)

    Nielsen, Steen Levin; Nielsen, Anne Lerberg; Vind, Susanne Haase

    2011-01-01

    An inflatable small plastic bag including a photo sensor was constructed for measurement of skin perfusion pressure avoiding the rim of the photo sensor over bony and tendineous surfaces of the tibia below the knee, at the ankle, and on the dorsal forefoot. Compression was obtained using a conical...... blood pressure cuff with continuous decrease from suprasystolic arm pressure. The validity of skin perfusion pressure with the new device was compared to that of isotope washout below the knee in normal subjects and in patients with an ischemic forefoot with acceptable agreement. The method had a high...... reproducibility within and between days in normal subjects. Compared to systolic arterial pressure measured using a strain gauge with a cuff on the ankle in normal subjects and patients with intermittent claudication the new device showed blood pressure in the skin closer to the diastolic pressure. The new...

  8. Tuukka Kaidesoja on Critical Realist Transcendental Realism

    Directory of Open Access Journals (Sweden)

    Groff Ruth

    2015-09-01

    Full Text Available I argue that critical realists think pretty much what Tukka Kaidesoja says that he himself thinks, but also that Kaidesoja’s objections to the views that he attributes to critical realists are not persuasive.

  9. Margin improvement initiatives: realistic approaches

    Energy Technology Data Exchange (ETDEWEB)

    Chan, P.K.; Paquette, S. [Royal Military College of Canada, Chemistry and Chemical Engineering Dept., Kingston, ON (Canada); Cunning, T.A. [Department of National Defence, Ottawa, ON (Canada); French, C.; Bonin, H.W. [Royal Military College of Canada, Chemistry and Chemical Engineering Dept., Kingston, ON (Canada); Pandey, M. [Univ. of Waterloo, Waterloo, ON (Canada); Murchie, M. [Cameco Fuel Manufacturing, Port Hope, ON (Canada)

    2014-07-01

    With reactor core aging, safety margins are particularly tight. Two realistic and practical approaches are proposed here to recover margins. The first project is related to the use of a small amount of neutron absorbers in CANDU Natural Uranium (NU) fuel bundles. Preliminary results indicate that the fuelling transient and subsequent reactivity peak can be lowered to improve the reactor's operating margins, with minimal impact on burnup when less than 1000 mg of absorbers is added to a fuel bundle. The second project involves the statistical analysis of fuel manufacturing data to demonstrate safety margins. Probability distributions are fitted to actual fuel manufacturing datasets provided by Cameco Fuel Manufacturing, Inc. They are used to generate input for ELESTRES and ELOCA. It is found that the fuel response distributions are far below industrial failure limits, implying that margin exists in the current fuel design. (author)

  10. PARP-1 Variant Rs1136410 Confers Protection against Coronary Artery Disease in a Chinese Han Population: A Two-Stage Case-Control Study Involving 5643 Subjects

    Directory of Open Access Journals (Sweden)

    Xue-bin Wang

    2017-11-01

    Full Text Available Inhibition of poly(ADP-ribose polymerase (PARP may protect against coronary artery disease (CAD in animal models, and rs1136410, a non-synonymous single nucleotide polymorphism (SNP in PARP-1, has a potential impact on PARP activities in vitro. This two-stage case-control study, involving 2803 CAD patients and 2840 controls, aimed to investigate the associations of PARP-1 rs1136410 with CAD development, lipid levels, PARP activities, 8-hydroxy-2′-dexyguanosine (8-OHdG, and interleukin (IL-6 levels in a Chinese Han population. Assuming a recessive model, the variant genotype GG of SNP rs1136410 showed a significantly inverse association with CAD risk (adjusted odds ratio (OR = 0.73, P < 0.001, left main coronary artery (LMCA lesions (P = 0.003, vessel scores (P = 0.003, and modified Gensini scores (P < 0.001. There were significant correlations of SNP rs1136410 with higher levels of total cholesterol (TC and lower levels of high-density lipoprotein cholesterol (HDL-c. In gene-environment interaction analyses, participants with the variant genotype GG, but without smoking habit, type 2 diabetes mellitus, and hyperlipidemia, conferred an 84% (P < 0.001 decreased risk of CAD. The genotype-phenotype correlation analyses further supported the functional roles of SNP rs1136410 in decreasing PARP activities and 8-OHdG levels. Taken together, our data suggest that SNP rs1136410 may confer protection against CAD through modulation of PARP activities and gene-environment interactions in a Chinese Han population.

  11. Effects of opium consumption on coronary artery disease risk factors and oral health: Results of Kerman Coronary Artery Disease Risk factors Study a population-based survey on 5900 subjects aged 15-75 years.

    Science.gov (United States)

    Najafipour, Hamid; Masoomi, Mohammad; Shahesmaeili, Armita; Haghdoost, Ali Akbar; Afshari, Mahdi; Nasri, Hamid Reza; Kahnooji, Masoomeh; Samadi, Sadra; Mirzazadeh, Ali

    2015-01-01

    Opium abuse as a relatively common behavior among Iranian population may have an association with the other coronary artery disease (CAD) risk factors. Here, we reported the prevalence of opium abuse and its co-exposures with oral health and other CAD risk factors. We recruited 5900 inhabitant aged 15-75 years using a randomized cluster household survey. All were interviewed for level of physical activity (PA), depression, anxiety and opium use and assessed for hypertension, diabetes, hyperlipidemia, and oral health status. Regarding to opium abuse, participants were grouped into: "Non-," "occasional," and "dependent" users. Using logistic regression model for every CAD risk factor, we assessed whether the co-exposure of opium and CAD risk factor is significant. Overall, 10.6% reported ever opium use including 5.6% dependent and 5% occasional users. The prevalence of opium abuse was increased from 2.1% in 15-25 years to 24.5% in 55-64 years group. Opium abuse, in occasional and dependent forms, was associated with depression (adjusted odds ratio [AOR] 1.81 and 2.49) and low PS (AOR 1.43 and 1.71 respectively). Dependents were less obese than nonusers (P Opium abuse had no significant association with hypertension, diabetes, oral health status and lipid profile. Opium abuse was associated with depression and low PA. No ameliorative effect was observed on hypertension, diabetes, and plasma lipid profile. Therefore, positive association of opium with depression and LPA and the incorrectness of belief on its ameliorative effect on three other important risk factors of CAD should be clearly highlighted in public health messages to the community.

  12. Realistic Simulation of Rice Plant

    Directory of Open Access Journals (Sweden)

    Wei-long DING

    2011-09-01

    Full Text Available The existing research results of virtual modeling of rice plant, however, is far from perfect compared to that of other crops due to its complex structure and growth process. Techniques to visually simulate the architecture of rice plant and its growth process are presented based on the analysis of the morphological characteristics at different stages. Firstly, the simulations of geometrical shape, the bending status and the structural distortion of rice leaves are conducted. Then, by using an improved model for bending deformation, the curved patterns of panicle axis and various types of panicle branches are generated, and the spatial shape of rice panicle is therefore created. Parametric L-system is employed to generate its topological structures, and finite-state automaton is adopted to describe the development of geometrical structures. Finally, the computer visualization of three-dimensional morphologies of rice plant at both organ and individual levels is achieved. The experimental results showed that the proposed methods of modeling the three-dimensional shapes of organs and simulating the growth of rice plant are feasible and effective, and the generated three-dimensional images are realistic.

  13. Problem Posing with Realistic Mathematics Education Approach in Geometry Learning

    Science.gov (United States)

    Mahendra, R.; Slamet, I.; Budiyono

    2017-09-01

    One of the difficulties of students in the learning of geometry is on the subject of plane that requires students to understand the abstract matter. The aim of this research is to determine the effect of Problem Posing learning model with Realistic Mathematics Education Approach in geometry learning. This quasi experimental research was conducted in one of the junior high schools in Karanganyar, Indonesia. The sample was taken using stratified cluster random sampling technique. The results of this research indicate that the model of Problem Posing learning with Realistic Mathematics Education Approach can improve students’ conceptual understanding significantly in geometry learning especially on plane topics. It is because students on the application of Problem Posing with Realistic Mathematics Education Approach are become to be active in constructing their knowledge, proposing, and problem solving in realistic, so it easier for students to understand concepts and solve the problems. Therefore, the model of Problem Posing learning with Realistic Mathematics Education Approach is appropriately applied in mathematics learning especially on geometry material. Furthermore, the impact can improve student achievement.

  14. Effect of Improving Dietary Quality on Arterial Stiffness in Subjects with Type 1 and Type 2 Diabetes: A 12 Months Randomised Controlled Trial

    Directory of Open Access Journals (Sweden)

    Kristina S. Petersen

    2016-06-01

    Full Text Available People with diabetes have accelerated arterial stiffening. The aim of this study was to determine the effect of increasing fruit, vegetable and dairy intake for 12 months on carotid femoral pulse wave velocity (cfPWV, augmentation index (AIx, and central blood pressure (cBP, compared to a usual diet control, in people with type 1 and type 2 diabetes. In a 12 months randomised controlled trial, cfPWV, AIx and cBP were measured every 3 months. The intervention group received dietary counselling to increase consumption of fruit (+1 serving/day; 150 g/day, vegetables (+2 servings/day; 150 g/day and dairy (+1 serving/day; 200–250 g/day at baseline, 1, 3, 6 and 9 months. The control group continued on their usual diet. One hundred and nine participants were randomised and 92 (intervention n = 45; control n = 47 completed. At 3 months, fruit (184 g/day; p = 0.001 and dairy (83 g/day; p = 0.037 intake increased in the intervention group compared with the control group but this increase was not maintained at 12 months. After adjustment for baseline measurements there was no time by treatment effect for central systolic or diastolic BP, AIx or cfPWV. A time effect existed for AIx which modestly increased over time. Peripheral diastolic BP and central pulse pressure were improved in the intervention group compared with the control group at 12 months. In the cohort with type 1 and type 2 diabetes, improving dietary quality by increasing consumption of fruit, vegetables and dairy did not improve cBP, AIx or cfPWV, compared with a control group continuing on their usual diet, after 12 months.

  15. Skin perfusion pressure measured with a photo sensor in an air-filled plastic balloon: validity and reproducibility on the lower leg in normal subjects and patients suspected of obliterative arterial disease

    International Nuclear Information System (INIS)

    Nielsen, Steen Levin; Nielsen, Anne Lerberg; Vind, Susanne Haase; Thomassen, Anders

    2011-01-01

    An inflatable small plastic bag including a photo sensor was constructed for measurement of skin perfusion pressure avoiding the rim of the photo sensor over bony and tendineous surfaces of the tibia below the knee, at the ankle, and on the dorsal forefoot. Compression was obtained using a conical blood pressure cuff with continuous decrease from suprasystolic arm pressure. The validity of skin perfusion pressure with the new device was compared to that of isotope washout below the knee in normal subjects and in patients with an ischemic forefoot with acceptable agreement. The method had a high reproducibility within and between days in normal subjects. Compared to systolic arterial pressure measured using a strain gauge with a cuff on the ankle in normal subjects and patients with intermittent claudication the new device showed blood pressure in the skin closer to the diastolic pressure. The new pressure device thus had acceptable validity and reproducibility for estimation of the skin perfusion pressure and can be used on bony and tendineous sites on the lower limb in regions where critical wound healing is frequent, e.g. ankle and forefoot

  16. Progress in realistic LOCA analysis

    International Nuclear Information System (INIS)

    Young, M.Y.; Bajorek, S.M.; Ohkawa, K.

    2004-01-01

    In 1988 the USNRC revised the ECCS rule contained in Appendix K and Section 50.46 of 10 CFR Part 50, which governs the analysis of the Loss Of Coolant Accident (LOCA). The revised regulation allows the use of realistic computer models to calculate the loss of coolant accident. In addition, the new regulation allows the use of high probability estimates of peak cladding temperature (PCT), rather than upper bound estimates. Prior to this modification, the regulations were a prescriptive set of rules which defined what assumptions must be made about the plant initial conditions and how various physical processes should be modeled. The resulting analyses were highly conservative in their prediction of the performance of the ECCS, and placed tight constraints on core power distributions, ECCS set points and functional requirements, and surveillance and testing. These restrictions, if relaxed, will allow for additional economy, flexibility, and in some cases, improved reliability and safety as well. For example, additional economy and operating flexibility can be achieved by implementing several available core and fuel rod designs to increase fuel discharge burnup and reduce neutron flux on the reactor vessel. The benefits of application of best estimate methods to LOCA analyses have typically been associated with reductions in fuel costs, resulting from optimized fuel designs, or increased revenue from power upratings. Fuel cost savings are relatively easy to quantify, and have been estimated at several millions of dollars per cycle for an individual plant. Best estimate methods are also likely to contribute significantly to reductions in O and M costs, although these reductions are more difficult to quantify. Examples of O and M cost reductions are: 1) Delaying equipment replacement. With best estimate methods, LOCA is no longer a factor in limiting power levels for plants with high tube plugging levels or degraded safety injection systems. If other requirements for

  17. Generating realistic roofs over a rectilinear polygon

    KAUST Repository

    Ahn, Heekap

    2011-01-01

    Given a simple rectilinear polygon P in the xy-plane, a roof over P is a terrain over P whose faces are supported by planes through edges of P that make a dihedral angle π/4 with the xy-plane. In this paper, we introduce realistic roofs by imposing a few additional constraints. We investigate the geometric and combinatorial properties of realistic roofs, and show a connection with the straight skeleton of P. We show that the maximum possible number of distinct realistic roofs over P is ( ⌊(n-4)/4⌋ (n-4)/2) when P has n vertices. We present an algorithm that enumerates a combinatorial representation of each such roof in O(1) time per roof without repetition, after O(n 4) preprocessing time. We also present an O(n 5)-time algorithm for computing a realistic roof with minimum height or volume. © 2011 Springer-Verlag.

  18. Results of recent calculations using realistic potentials

    International Nuclear Information System (INIS)

    Friar, J.L.

    1987-01-01

    Results of recent calculations for the triton using realistic potentials with strong tensor forces are reviewed, with an emphasis on progress made using the many different calculational schemes. Several test problems are suggested. 49 refs., 5 figs

  19. Sotsialistlik realist Keskküla

    Index Scriptorium Estoniae

    1998-01-01

    Londonis 1998. a. ilmunud inglise kunstikriitiku Matthew Cullerne Bowni monograafias "Socialist Realist Painting" on eesti kunstnikest Enn Põldroos, Nikolai Kormashov, Ando Keskküla, Kormashovi ja Keskküla maalide reproduktsioonid

  20. Development of a model of the coronary arterial tree for the 4D XCAT phantom

    International Nuclear Information System (INIS)

    Fung, George S K; Tsui, Benjamin M W; Segars, W Paul; Gullberg, Grant T

    2011-01-01

    A detailed three-dimensional (3D) model of the coronary artery tree with cardiac motion has great potential for applications in a wide variety of medical imaging research areas. In this work, we first developed a computer-generated 3D model of the coronary arterial tree for the heart in the extended cardiac-torso (XCAT) phantom, thereby creating a realistic computer model of the human anatomy. The coronary arterial tree model was based on two datasets: (1) a gated cardiac dual-source computed tomography (CT) angiographic dataset obtained from a normal human subject and (2) statistical morphometric data of porcine hearts. The initial proximal segments of the vasculature and the anatomical details of the boundaries of the ventricles were defined by segmenting the CT data. An iterative rule-based generation method was developed and applied to extend the coronary arterial tree beyond the initial proximal segments. The algorithm was governed by three factors: (1) statistical morphometric measurements of the connectivity, lengths and diameters of the arterial segments; (2) avoidance forces from other vessel segments and the boundaries of the myocardium, and (3) optimality principles which minimize the drag force at the bifurcations of the generated tree. Using this algorithm, the 3D computational model of the largest six orders of the coronary arterial tree was generated, which spread across the myocardium of the left and right ventricles. The 3D coronary arterial tree model was then extended to 4D to simulate different cardiac phases by deforming the original 3D model according to the motion vector map of the 4D cardiac model of the XCAT phantom at the corresponding phases. As a result, a detailed and realistic 4D model of the coronary arterial tree was developed for the XCAT phantom by imposing constraints of anatomical and physiological characteristics of the coronary vasculature. This new 4D coronary artery tree model provides a unique simulation tool that can be

  1. Realistic roofs over a rectilinear polygon

    KAUST Repository

    Ahn, Heekap

    2013-11-01

    Given a simple rectilinear polygon P in the xy-plane, a roof over P is a terrain over P whose faces are supported by planes through edges of P that make a dihedral angle π/4 with the xy-plane. According to this definition, some roofs may have faces isolated from the boundary of P or even local minima, which are undesirable for several practical reasons. In this paper, we introduce realistic roofs by imposing a few additional constraints. We investigate the geometric and combinatorial properties of realistic roofs and show that the straight skeleton induces a realistic roof with maximum height and volume. We also show that the maximum possible number of distinct realistic roofs over P is ((n-4)(n-4)/4 /2⌋) when P has n vertices. We present an algorithm that enumerates a combinatorial representation of each such roof in O(1) time per roof without repetition, after O(n4) preprocessing time. We also present an O(n5)-time algorithm for computing a realistic roof with minimum height or volume. © 2013 Elsevier B.V.

  2. Development of a realistic human airway model.

    Science.gov (United States)

    Lizal, Frantisek; Elcner, Jakub; Hopke, Philip K; Jedelsky, Jan; Jicha, Miroslav

    2012-03-01

    Numerous models of human lungs with various levels of idealization have been reported in the literature; consequently, results acquired using these models are difficult to compare to in vivo measurements. We have developed a set of model components based on realistic geometries, which permits the analysis of the effects of subsequent model simplification. A realistic digital upper airway geometry except for the lack of an oral cavity has been created which proved suitable both for computational fluid dynamics (CFD) simulations and for the fabrication of physical models. Subsequently, an oral cavity was added to the tracheobronchial geometry. The airway geometry including the oral cavity was adjusted to enable fabrication of a semi-realistic model. Five physical models were created based on these three digital geometries. Two optically transparent models, one with and one without the oral cavity, were constructed for flow velocity measurements, two realistic segmented models, one with and one without the oral cavity, were constructed for particle deposition measurements, and a semi-realistic model with glass cylindrical airways was developed for optical measurements of flow velocity and in situ particle size measurements. One-dimensional phase doppler anemometry measurements were made and compared to the CFD calculations for this model and good agreement was obtained.

  3. Arterial stick

    Science.gov (United States)

    ... be some throbbing. Why the Test Is Performed Blood transports oxygen, nutrients, waste products, and other materials within ... venous blood) mainly in its content of dissolved gases . Testing arterial blood shows the makeup of the blood before any ...

  4. Iterated interactions method. Realistic NN potential

    International Nuclear Information System (INIS)

    Gorbatov, A.M.; Skopich, V.L.; Kolganova, E.A.

    1991-01-01

    The method of iterated potential is tested in the case of realistic fermionic systems. As a base for comparison calculations of the 16 O system (using various versions of realistic NN potentials) by means of the angular potential-function method as well as operators of pairing correlation were used. The convergence of genealogical series is studied for the central Malfliet-Tjon potential. In addition the mathematical technique of microscopical calculations is improved: new equations for correlators in odd states are suggested and the technique of leading terms was applied for the first time to calculations of heavy p-shell nuclei in the basis of angular potential functions

  5. Are there realistically interpretable local theories?

    International Nuclear Information System (INIS)

    d'Espagnat, B.

    1989-01-01

    Although it rests on strongly established proofs, the statement that no realistically interpretable local theory is compatible with some experimentally testable predictions of quantum mechanics seems at first sight to be incompatible with a few general ideas and clear-cut statements occurring in recent theoretical work by Griffiths, Omnes, and Ballentine and Jarrett. It is shown here that in fact none of the developments due to these authors can be considered as a realistically interpretable local theory, so that there is no valid reason for suspecting that the existing proofs of the statement in question are all flawed

  6. A Radiosity Approach to Realistic Image Synthesis

    Science.gov (United States)

    1992-12-01

    AD-A259 082 AFIT/GCE/ENG/92D-09 A RADIOSITY APPROACH TO REALISTIC IMAGE SYNTHESIS THESIS Richard L. Remington Captain, USAF fl ECTE AFIT/GCE/ENG/92D...09 SJANl 1993U 93-00134 Approved for public release; distribution unlimited 93& 1! A -A- AFIT/GCE/ENG/92D-09 A RADIOSITY APPROACH TO REALISTIC IMAGE...assistance in creating the input geometry file for the AWACS aircraft interior. Without his assistance, a good model for the diffuse radiosity implementation

  7. Liver cirrhosis and arterial hypertension

    DEFF Research Database (Denmark)

    Henriksen, Jens Henrik; Møller, Søren

    2006-01-01

    blood pressure. This review considers the alterations in systemic hemodynamics in patients with cirrhosis in relation to essential hypertension and arterial hypertension of the renal origin. Subjects with arterial hypertension (essential, secondary) may become normotensive during the development......Characteristic findings in patients with cirrhosis are vasodilatation with low overall systemic vascular resistance, high arterial compliance, increased cardiac output, secondary activation of counter-regulatory systems (renin-angiotensin-aldosterone system, sympathetic nervous system, release...... of cirrhosis, and arterial hypertension is rarely manifested in patients with cirrhosis, even in cases with renovascular disease and high circulating renin activity. There is much dispute as to the understanding of homoeostatic regulation in cirrhotic patients with manifest arterial hypertension. This most...

  8. Arterial stiffness

    Directory of Open Access Journals (Sweden)

    Ursula Quinn

    2012-09-01

    Full Text Available Measurements of biomechanical properties of arteries have become an important surrogate outcome used in epidemiological and interventional cardiovascular research. Structural and functional differences of vessels in the arterial tree result in a dampening of pulsatility and smoothing of blood flow as it progresses to capillary level. A loss of arterial elastic properties results a range of linked pathophysiological changes within the circulation including increased pulse pressure, left ventricular hypertrophy, subendocardial ischaemia, vessel endothelial dysfunction and cardiac fibrosis. With increased arterial stiffness, the microvasculature of brain and kidneys are exposed to wider pressure fluctuations and may lead to increased risk of stroke and renal failure. Stiffening of the aorta, as measured by the gold-standard technique of aortic Pulse Wave Velocity (aPWV, is independently associated with adverse cardiovascular outcomes across many different patient groups and in the general population. Therefore, use of aPWV has been proposed for early detection of vascular damage and individual cardiovascular risk evaluation and it seems certain that measurement of arterial stiffness will become increasingly important in future clinical care. In this review we will consider some of the pathophysiological processes that result from arterial stiffening, how it is measured and factors that may drive it as well as potential avenues for therapy. In the face of an ageing population where mortality from atheromatous cardiovascular disease is falling, pathology associated with arterial stiffening will assume ever greater importance. Therefore, understanding these concepts for all clinicians involved in care of patients with cardiovascular disease will become vital.

  9. On Realistically Attacking Tor with Website Fingerprinting

    Directory of Open Access Journals (Sweden)

    Wang Tao

    2016-10-01

    Full Text Available Website fingerprinting allows a local, passive observer monitoring a web-browsing client’s encrypted channel to determine her web activity. Previous attacks have shown that website fingerprinting could be a threat to anonymity networks such as Tor under laboratory conditions. However, there are significant differences between laboratory conditions and realistic conditions. First, in laboratory tests we collect the training data set together with the testing data set, so the training data set is fresh, but an attacker may not be able to maintain a fresh data set. Second, laboratory packet sequences correspond to a single page each, but for realistic packet sequences the split between pages is not obvious. Third, packet sequences may include background noise from other types of web traffic. These differences adversely affect website fingerprinting under realistic conditions. In this paper, we tackle these three problems to bridge the gap between laboratory and realistic conditions for website fingerprinting. We show that we can maintain a fresh training set with minimal resources. We demonstrate several classification-based techniques that allow us to split full packet sequences effectively into sequences corresponding to a single page each. We describe several new algorithms for tackling background noise. With our techniques, we are able to build the first website fingerprinting system that can operate directly on packet sequences collected in the wild.

  10. Satellite Maps Deliver More Realistic Gaming

    Science.gov (United States)

    2013-01-01

    When Redwood City, California-based Electronic Arts (EA) decided to make SSX, its latest snowboarding video game, it faced challenges in creating realistic-looking mountains. The solution was NASA's ASTER Global Digital Elevation Map, made available by the Jet Propulsion Laboratory, which EA used to create 28 real-life mountains from 9 different ranges for its award-winning game.

  11. Realistic searches on stretched exponential networks

    Indian Academy of Sciences (India)

    We consider navigation or search schemes on networks which have a degree distribution of the form () ∝ exp(−). In addition, the linking probability is taken to be dependent on social distances and is governed by a parameter . The searches are realistic in the sense that not all search chains can be completed.

  12. Generating realistic roofs over a rectilinear polygon

    KAUST Repository

    Ahn, Heekap; Bae, Sangwon; Knauer, Christian; Lee, Mira; Shin, Chansu; Vigneron, Antoine E.

    2011-01-01

    Given a simple rectilinear polygon P in the xy-plane, a roof over P is a terrain over P whose faces are supported by planes through edges of P that make a dihedral angle π/4 with the xy-plane. In this paper, we introduce realistic roofs by imposing

  13. Carotid artery surgery

    Science.gov (United States)

    Carotid endarterectomy; CAS surgery; Carotid artery stenosis - surgery; Endarterectomy - carotid artery ... through the catheter around the blocked area during surgery. Your carotid artery is opened. The surgeon removes ...

  14. Arterial variations of upper limb: a case report

    Directory of Open Access Journals (Sweden)

    Vollala V

    2005-01-01

    Full Text Available Variations of upper limb arteries are common and there are many reports about this subject. We report multiple variations in arterial pattern of upper extremity, which were encountered in a single cadaver.

  15. Arterial stiffness and cognitive impairment.

    Science.gov (United States)

    Li, Xiaoxuan; Lyu, Peiyuan; Ren, Yanyan; An, Jin; Dong, Yanhong

    2017-09-15

    Arterial stiffness is one of the earliest indicators of changes in vascular wall structure and function and may be assessed using various indicators, such as pulse-wave velocity (PWV), the cardio-ankle vascular index (CAVI), the ankle-brachial index (ABI), pulse pressure (PP), the augmentation index (AI), flow-mediated dilation (FMD), carotid intima media thickness (IMT) and arterial stiffness index-β. Arterial stiffness is generally considered an independent predictor of cardiovascular and cerebrovascular diseases. To date, a significant number of studies have focused on the relationship between arterial stiffness and cognitive impairment. To investigate the relationships between specific arterial stiffness parameters and cognitive impairment, elucidate the pathophysiological mechanisms underlying the relationship between arterial stiffness and cognitive impairment and determine how to interfere with arterial stiffness to prevent cognitive impairment, we searched PUBMED for studies regarding the relationship between arterial stiffness and cognitive impairment that were published from 2000 to 2017. We used the following key words in our search: "arterial stiffness and cognitive impairment" and "arterial stiffness and cognitive impairment mechanism". Studies involving human subjects older than 30years were included in the review, while irrelevant studies (i.e., studies involving subjects with comorbid kidney disease, diabetes and cardiac disease) were excluded from the review. We determined that arterial stiffness severity was positively correlated with cognitive impairment. Of the markers used to assess arterial stiffness, a higher PWV, CAVI, AI, IMT and index-β and a lower ABI and FMD were related to cognitive impairment. However, the relationship between PP and cognitive impairment remained controversial. The potential mechanisms linking arterial stiffness and cognitive impairment may be associated with arterial pulsatility, as greater arterial pulsatility

  16. Arterial embolism

    Science.gov (United States)

    ... when a clot in a vein enters the right side of the heart and passes through a hole into the left side. The clot can then move to an artery and block blood flow to the brain (stroke) or other organs. If a clot involves ...

  17. Separable expansion for realistic multichannel scattering problems

    International Nuclear Information System (INIS)

    Canton, L.; Cattapan, G.; Pisent, G.

    1987-01-01

    A new approach to the multichannel scattering problem with realistic local or nonlocal interactions is developed. By employing the negative-energy solutions of uncoupled Sturmian eigenvalue problems referring to simple auxiliary potentials, the coupling interactions appearing to the original multichannel problem are approximated by finite-rank potentials. By resorting to integral-equation tecniques the coupled-channel equations are then reduced to linear algebraic equations which can be straightforwardly solved. Compact algebraic expressions for the relevant scattering matrix elements are thus obtained. The convergence of the method is tasted in the single-channel case with realistic optical potentials. Excellent agreement is obtained with a few terms in the separable expansion for both real and absorptive interactions

  18. Realistic Approach for Phasor Measurement Unit Placement

    DEFF Research Database (Denmark)

    Rather, Zakir Hussain; Chen, Zhe; Thøgersen, Paul

    2015-01-01

    This paper presents a realistic cost-effectivemodel for optimal placement of phasor measurement units (PMUs) for complete observability of a power system considering practical cost implications. The proposed model considers hidden or otherwise unaccounted practical costs involved in PMU...... installation. Consideration of these hidden but significant and integral part of total PMU installation costs was inspired from practical experience on a real-life project. The proposedmodel focuses on the minimization of total realistic costs instead of a widely used theoretical concept of a minimal number...... of PMUs. The proposed model has been applied to IEEE 14-bus, IEEE 24-bus, IEEE 30-bus, New England 39-bus, and large power system of 300 buses and real life Danish grid. A comparison of the presented results with those reported by traditionalmethods has also been shown to justify the effectiveness...

  19. RenderGAN: Generating Realistic Labeled Data

    Directory of Open Access Journals (Sweden)

    Leon Sixt

    2018-06-01

    Full Text Available Deep Convolutional Neuronal Networks (DCNNs are showing remarkable performance on many computer vision tasks. Due to their large parameter space, they require many labeled samples when trained in a supervised setting. The costs of annotating data manually can render the use of DCNNs infeasible. We present a novel framework called RenderGAN that can generate large amounts of realistic, labeled images by combining a 3D model and the Generative Adversarial Network framework. In our approach, image augmentations (e.g., lighting, background, and detail are learned from unlabeled data such that the generated images are strikingly realistic while preserving the labels known from the 3D model. We apply the RenderGAN framework to generate images of barcode-like markers that are attached to honeybees. Training a DCNN on data generated by the RenderGAN yields considerably better performance than training it on various baselines.

  20. Realistic molecular model of kerogen's nanostructure.

    Science.gov (United States)

    Bousige, Colin; Ghimbeu, Camélia Matei; Vix-Guterl, Cathie; Pomerantz, Andrew E; Suleimenova, Assiya; Vaughan, Gavin; Garbarino, Gaston; Feygenson, Mikhail; Wildgruber, Christoph; Ulm, Franz-Josef; Pellenq, Roland J-M; Coasne, Benoit

    2016-05-01

    Despite kerogen's importance as the organic backbone for hydrocarbon production from source rocks such as gas shale, the interplay between kerogen's chemistry, morphology and mechanics remains unexplored. As the environmental impact of shale gas rises, identifying functional relations between its geochemical, transport, elastic and fracture properties from realistic molecular models of kerogens becomes all the more important. Here, by using a hybrid experimental-simulation method, we propose a panel of realistic molecular models of mature and immature kerogens that provide a detailed picture of kerogen's nanostructure without considering the presence of clays and other minerals in shales. We probe the models' strengths and limitations, and show that they predict essential features amenable to experimental validation, including pore distribution, vibrational density of states and stiffness. We also show that kerogen's maturation, which manifests itself as an increase in the sp(2)/sp(3) hybridization ratio, entails a crossover from plastic-to-brittle rupture mechanisms.

  1. Arterial vascularization of the pineal gland.

    Science.gov (United States)

    Kahilogullari, Gokmen; Ugur, Hasan Caglar; Comert, Ayhan; Brohi, Recep Ali; Ozgural, Onur; Ozdemir, Mevci; Karahan, Suleyman Tuna

    2013-10-01

    The arterial vascularization of the pineal gland (PG) remains a debatable subject. This study aims to provide detailed information about the arterial vascularization of the PG. Thirty adult human brains were obtained from routine autopsies. Cerebral arteries were separately cannulated and injected with colored latex. The dissections were carried out using a surgical microscope. The diameters of the branches supplying the PG at their origin and vascularization areas of the branches of the arteries were investigated. The main artery of the PG was the lateral pineal artery, and it originated from the posterior circulation. The other arteries included the medial pineal artery from the posterior circulation and the rostral pineal artery mainly from the anterior circulation. Posteromedial choroidal artery was an important artery that branched to the PG. The arterial supply to the PG was studied comprehensively considering the debate and inadequacy of previously published studies on this issue available in the literature. This anatomical knowledge may be helpful for surgical treatment of pathologies of the PG, especially in children who develop more pathology in this region than adults.

  2. Non realist tendencies in new Turkish cinema

    OpenAIRE

    Can, İclal

    2016-01-01

    http://hdl.handle.net/11693/29111 Thesis (M.S.): Bilkent University, Department of Communication and Design, İhsan Doğramacı Bilkent University, 2016. Includes bibliographical references (leaves 113-123). The realist tendency which had been dominant in cinema became more apparent with Italian neorealism affecting other national cinemas to a large extent. With the changing and developing socio economic and cultural dynamics, realism gradually has stopped being a natural const...

  3. Security of quantum cryptography with realistic sources

    International Nuclear Information System (INIS)

    Lutkenhaus, N.

    1999-01-01

    The interest in practical implementations of quantum key distribution is steadily growing. However, there is still a need to give a precise security statement which adapts to realistic implementation. In this paper I give the effective key rate we can obtain in a practical setting within scenario of security against individual attacks by an eavesdropper. It illustrates previous results that high losses together with detector dark counts can make secure quantum key distribution impossible. (Author)

  4. Quantifying introgression risk with realistic population genetics

    OpenAIRE

    Ghosh, Atiyo; Meirmans, Patrick G.; Haccou, Patsy

    2012-01-01

    Introgression is the permanent incorporation of genes from the genome of one population into another. This can have severe consequences, such as extinction of endemic species, or the spread of transgenes. Quantification of the risk of introgression is an important component of genetically modified crop regulation. Most theoretical introgression studies aimed at such quantification disregard one or more of the most important factors concerning introgression: realistic genetical mechanisms, rep...

  5. Quantum cryptography: towards realization in realistic conditions

    Energy Technology Data Exchange (ETDEWEB)

    Imoto, M; Koashi, M; Shimizu, K [NTT Basic Research Laboratories, 3-1 Morinosato-Wakamiya, Atsugi-shi, Kanagawa 243-01 (Japan); Huttner, B [Universite de Geneve, GAP-optique, 20, Rue de l` Ecole de Medecine CH1211, Geneve 4 (Switzerland)

    1997-05-11

    Many of quantum cryptography schemes have been proposed based on some assumptions such as no transmission loss, no measurement error, and an ideal single photon generator. We have been trying to develop a theory of quantum cryptography considering realistic conditions. As such attempts, we propose quantum cryptography with coherent states, quantum cryptography with two-photon interference, and generalization of two-state cryptography to two-mixed-state cases. (author) 15 refs., 1 fig., 1 tab.

  6. Security of quantum cryptography with realistic sources

    Energy Technology Data Exchange (ETDEWEB)

    Lutkenhaus, N [Helsinki Institute of Physics, P.O. Box 9, 00014 Helsingin yliopisto (Finland)

    1999-08-01

    The interest in practical implementations of quantum key distribution is steadily growing. However, there is still a need to give a precise security statement which adapts to realistic implementation. In this paper I give the effective key rate we can obtain in a practical setting within scenario of security against individual attacks by an eavesdropper. It illustrates previous results that high losses together with detector dark counts can make secure quantum key distribution impossible. (Author)

  7. Quantum cryptography: towards realization in realistic conditions

    International Nuclear Information System (INIS)

    Imoto, M.; Koashi, M.; Shimizu, K.; Huttner, B.

    1997-01-01

    Many of quantum cryptography schemes have been proposed based on some assumptions such as no transmission loss, no measurement error, and an ideal single photon generator. We have been trying to develop a theory of quantum cryptography considering realistic conditions. As such attempts, we propose quantum cryptography with coherent states, quantum cryptography with two-photon interference, and generalization of two-state cryptography to two-mixed-state cases. (author)

  8. The artery blood supply variant of the upper limb

    Science.gov (United States)

    MASLARSKI, IVAN

    2015-01-01

    Variations of arterial patterns in the upper limb have represented the most common subject of vascular anatomy. Different types of artery branching pattern of the upper limb are very important for orthopedists in angiographic and microvascular surgical practice. The brachial artery (BA) is the most important vessel in the normal vascular anatomy of the upper limb. The classical pattern of the palmar hand region distribution shows the superficial palmar arch. Normally this arch is formed by the superficial branch of the ulnar artery and completed on the lateral side by one of these arteries: the superficial palmar branch of the radial artery, the princeps pollicis artery, the superficial palmar branch of the radial artery or the median artery. After the routine dissection of the right upper limb of an adult male cadaver, we found a very rare variant of the superficial arch artery – a division in a higher level brachial artery. We found this division at 10.4 cm from the beginning of the brachial artery. This superficial brachial artery became a radial artery and was not involved in the formation of the palm arch. In the forearm region, the artery variant was present with the median artery and the ulnar artery, which form the superficial palm arch. PMID:26733754

  9. Realistic and efficient 2D crack simulation

    Science.gov (United States)

    Yadegar, Jacob; Liu, Xiaoqing; Singh, Abhishek

    2010-04-01

    Although numerical algorithms for 2D crack simulation have been studied in Modeling and Simulation (M&S) and computer graphics for decades, realism and computational efficiency are still major challenges. In this paper, we introduce a high-fidelity, scalable, adaptive and efficient/runtime 2D crack/fracture simulation system by applying the mathematically elegant Peano-Cesaro triangular meshing/remeshing technique to model the generation of shards/fragments. The recursive fractal sweep associated with the Peano-Cesaro triangulation provides efficient local multi-resolution refinement to any level-of-detail. The generated binary decomposition tree also provides efficient neighbor retrieval mechanism used for mesh element splitting and merging with minimal memory requirements essential for realistic 2D fragment formation. Upon load impact/contact/penetration, a number of factors including impact angle, impact energy, and material properties are all taken into account to produce the criteria of crack initialization, propagation, and termination leading to realistic fractal-like rubble/fragments formation. The aforementioned parameters are used as variables of probabilistic models of cracks/shards formation, making the proposed solution highly adaptive by allowing machine learning mechanisms learn the optimal values for the variables/parameters based on prior benchmark data generated by off-line physics based simulation solutions that produce accurate fractures/shards though at highly non-real time paste. Crack/fracture simulation has been conducted on various load impacts with different initial locations at various impulse scales. The simulation results demonstrate that the proposed system has the capability to realistically and efficiently simulate 2D crack phenomena (such as window shattering and shards generation) with diverse potentials in military and civil M&S applications such as training and mission planning.

  10. Towards an agential realist concept of learning

    DEFF Research Database (Denmark)

    Plauborg, Helle

    2018-01-01

    Drawing on agential realism, this article explores how learning can be understood. An agential realist way of thinking about learning is sensitive to the complexity that characterises learning as a phenomenon. Thus, learning is seen as a dynamic and emergent phenomenon, constantly undergoing...... processes of becoming and expanding the range of components involved in such constitutive processes. With inspiration from Barad’s theorisation of spatiality, temporality and the interdependence of discourse and materiality, this article focuses on timespacemattering and material-discursivity. Concepts...

  11. MANAJEMEN LABA: PERILAKU MANAJEMEN OPPORTUNISTIC ATAU REALISTIC ?

    Directory of Open Access Journals (Sweden)

    I Nyoman Wijana Asmara Putra

    2011-01-01

    Full Text Available Earnings management is a still attractive issue. It is often associatedwith negative behavior conducted by management for its own interest. In fact,it also has different side to be examined. There is another motivation to do so,such as to improve the company’s operation. This literature study aims toreview management motivation of doing earnings management, whetheropportunistic or realistic. What conflict that earnings management brings,what pro and cons about it, what would happen if earnings is not managed,whether the company would be better off or worse off.

  12. Building Realistic Mobility Models for Mobile Ad Hoc Networks

    Directory of Open Access Journals (Sweden)

    Adrian Pullin

    2018-04-01

    Full Text Available A mobile ad hoc network (MANET is a self-configuring wireless network in which each node could act as a router, as well as a data source or sink. Its application areas include battlefields and vehicular and disaster areas. Many techniques applied to infrastructure-based networks are less effective in MANETs, with routing being a particular challenge. This paper presents a rigorous study into simulation techniques for evaluating routing solutions for MANETs with the aim of producing more realistic simulation models and thereby, more accurate protocol evaluations. MANET simulations require models that reflect the world in which the MANET is to operate. Much of the published research uses movement models, such as the random waypoint (RWP model, with arbitrary world sizes and node counts. This paper presents a technique for developing more realistic simulation models to test and evaluate MANET protocols. The technique is animation, which is applied to a realistic scenario to produce a model that accurately reflects the size and shape of the world, node count, movement patterns, and time period over which the MANET may operate. The animation technique has been used to develop a battlefield model based on established military tactics. Trace data has been used to build a model of maritime movements in the Irish Sea. Similar world models have been built using the random waypoint movement model for comparison. All models have been built using the ns-2 simulator. These models have been used to compare the performance of three routing protocols: dynamic source routing (DSR, destination-sequenced distance-vector routing (DSDV, and ad hoc n-demand distance vector routing (AODV. The findings reveal that protocol performance is dependent on the model used. In particular, it is shown that RWP models do not reflect the performance of these protocols under realistic circumstances, and protocol selection is subject to the scenario to which it is applied. To

  13. TMS modeling toolbox for realistic simulation.

    Science.gov (United States)

    Cho, Young Sun; Suh, Hyun Sang; Lee, Won Hee; Kim, Tae-Seong

    2010-01-01

    Transcranial magnetic stimulation (TMS) is a technique for brain stimulation using rapidly changing magnetic fields generated by coils. It has been established as an effective stimulation technique to treat patients suffering from damaged brain functions. Although TMS is known to be painless and noninvasive, it can also be harmful to the brain by incorrect focusing and excessive stimulation which might result in seizure. Therefore there is ongoing research effort to elucidate and better understand the effect and mechanism of TMS. Lately Boundary element method (BEM) and Finite element method (FEM) have been used to simulate the electromagnetic phenomenon of TMS. However, there is a lack of general tools to generate the models of TMS due to some difficulties in realistic modeling of the human head and TMS coils. In this study, we have developed a toolbox through which one can generate high-resolution FE TMS models. The toolbox allows creating FE models of the head with isotropic and anisotropic electrical conductivities in five different tissues of the head and the coils in 3D. The generated TMS model is importable to FE software packages such as ANSYS for further and efficient electromagnetic analysis. We present a set of demonstrative results of realistic simulation of TMS with our toolbox.

  14. Realistic Affective Forecasting: The Role of Personality

    Science.gov (United States)

    Hoerger, Michael; Chapman, Ben; Duberstein, Paul

    2016-01-01

    Affective forecasting often drives decision making. Although affective forecasting research has often focused on identifying sources of error at the event level, the present investigation draws upon the ‘realistic paradigm’ in seeking to identify factors that similarly influence predicted and actual emotions, explaining their concordance across individuals. We hypothesized that the personality traits neuroticism and extraversion would account for variation in both predicted and actual emotional reactions to a wide array of stimuli and events (football games, an election, Valentine’s Day, birthdays, happy/sad film clips, and an intrusive interview). As hypothesized, individuals who were more introverted and neurotic anticipated, correctly, that they would experience relatively more unpleasant emotional reactions, and those who were more extraverted and less neurotic anticipated, correctly, that they would experience relatively more pleasant emotional reactions. Personality explained 30% of the concordance between predicted and actual emotional reactions. Findings suggest three purported personality processes implicated in affective forecasting, highlight the importance of individual-differences research in this domain, and call for more research on realistic affective forecasts. PMID:26212463

  15. Double profunda brachii artery

    Directory of Open Access Journals (Sweden)

    Gavishiddappa A Hadimani

    2016-01-01

    Full Text Available Brachial artery (BA is a continuation of the axillary artery at the lower border of teres major. In the cubital fossa, BA divides into radial artery and ulnar artery as terminal branches. Large branch given from the BA in the upper part is profunda brachii artery. In the present case, we noticed double profunda brachii that arises from the BA. They are profunda brachii artery 1 and profunda brachii artery 2. Profunda brachii artery 1 arises in the proximal part of the BA and profunda brachii artery 2 arises distal to the profunda brachii artery 1. Both the arteries run inferolaterally in the spiral groove along with radial nerve. Variations of profunda brachii artery are important during harvesting of the lateral arm flaps and may lead to inadvertent injury during percutaneous arterial catheterization or injection of drugs.

  16. Acute arterial occlusion - kidney

    Science.gov (United States)

    ... main artery to the kidney is called the renal artery. Reduced blood flow through the renal artery can hurt kidney function. ... need include: Duplex Doppler ultrasound exam of the renal arteries to test blood flow MRI of the kidney arteries, which can show ...

  17. Two politicians in a realistic experiment: attraction, discrepancy, intensity of delivery, and attitude change

    NARCIS (Netherlands)

    Wiegman, O.

    1985-01-01

    The leader of the Socialists in the Dutch Parliament and his Liberal opponent participated in this realistic experiment. Identical TV interviews with the two politicians were recorded and shown to subjects of both parties. The intensity of delivery was also varied: emotional versus rational. Our

  18. Realistic page-turning of electronic books

    Science.gov (United States)

    Fan, Chaoran; Li, Haisheng; Bai, Yannan

    2014-01-01

    The booming electronic books (e-books), as an extension to the paper book, are popular with readers. Recently, many efforts are put into the realistic page-turning simulation o f e-book to improve its reading experience. This paper presents a new 3D page-turning simulation approach, which employs piecewise time-dependent cylindrical surfaces to describe the turning page and constructs smooth transition method between time-dependent cylinders. The page-turning animation is produced by sequentially mapping the turning page into the cylinders with different radii and positions. Compared to the previous approaches, our method is able to imitate various effects efficiently and obtains more natural animation of turning page.

  19. Realistic Simulations of Coronagraphic Observations with WFIRST

    Science.gov (United States)

    Rizzo, Maxime; Zimmerman, Neil; Roberge, Aki; Lincowski, Andrew; Arney, Giada; Stark, Chris; Jansen, Tiffany; Turnbull, Margaret; WFIRST Science Investigation Team (Turnbull)

    2018-01-01

    We present a framework to simulate observing scenarios with the WFIRST Coronagraphic Instrument (CGI). The Coronagraph and Rapid Imaging Spectrograph in Python (crispy) is an open-source package that can be used to create CGI data products for analysis and development of post-processing routines. The software convolves time-varying coronagraphic PSFs with realistic astrophysical scenes which contain a planetary architecture, a consistent dust structure, and a background field composed of stars and galaxies. The focal plane can be read out by a WFIRST electron-multiplying CCD model directly, or passed through a WFIRST integral field spectrograph model first. Several elementary post-processing routines are provided as part of the package.

  20. Operator representation for effective realistic interactions

    Energy Technology Data Exchange (ETDEWEB)

    Weber, Dennis; Feldmeier, Hans; Neff, Thomas [GSI Helmholtzzentrum fuer Schwerionenforschung GmbH, Darmstadt (Germany)

    2013-07-01

    We present a method to derive an operator representation from the partial wave matrix elements of effective realistic nucleon-nucleon potentials. This method allows to employ modern effective interactions, which are mostly given in matrix element representation, also in nuclear many-body methods requiring explicitly the operator representation, for example ''Fermionic Molecular Dynamics'' (FMD). We present results for the operator representation of effective interactions obtained from the Argonne V18 potential with the Uenitary Correlation Operator Method'' (UCOM) and the ''Similarity Renormalization Group'' (SRG). Moreover, the operator representation allows a better insight in the nonlocal structure of the potential: While the UCOM transformed potential only shows a quadratic momentum dependence, the momentum dependence of SRG transformed potentials is beyond such a simple polynomial form.

  1. Level density from realistic nuclear potentials

    International Nuclear Information System (INIS)

    Calboreanu, A.

    2006-01-01

    Nuclear level density of some nuclei is calculated using a realistic set of single particle states (sps). These states are derived from the parameterization of nuclear potentials that describe the observed sps over a large number of nuclei. This approach has the advantage that one can infer level density for nuclei that are inaccessible for a direct study, but are very important in astrophysical processes such as those close to the drip lines. Level densities at high excitation energies are very sensitive to the actual set of sps. The fact that the sps spectrum is finite has extraordinary consequences upon nuclear reaction yields due to the leveling-off of the level density at extremely high excitation energies wrongly attributed so far to other nuclear effects. Single-particle level density parameter a parameter is extracted by fitting the calculated densities to the standard Bethe formula

  2. Realistic microscopic level densities for spherical nuclei

    International Nuclear Information System (INIS)

    Cerf, N.

    1994-01-01

    Nuclear level densities play an important role in nuclear reactions such as the formation of the compound nucleus. We develop a microscopic calculation of the level density based on a combinatorial evaluation from a realistic single-particle level scheme. This calculation makes use of a fast Monte Carlo algorithm allowing us to consider large shell model spaces which could not be treated previously in combinatorial approaches. Since our model relies on a microscopic basis, it can be applied to exotic nuclei with more confidence than the commonly used semiphenomenological formuals. An exhaustive comparison of our predicted neutron s-wave resonance spacings with experimental data for a wide range of nuclei is presented

  3. HELIOSEISMOLOGY OF A REALISTIC MAGNETOCONVECTIVE SUNSPOT SIMULATION

    International Nuclear Information System (INIS)

    Braun, D. C.; Birch, A. C.; Rempel, M.; Duvall, T. L. Jr.

    2012-01-01

    We compare helioseismic travel-time shifts measured from a realistic magnetoconvective sunspot simulation using both helioseismic holography and time-distance helioseismology, and measured from real sunspots observed with the Helioseismic and Magnetic Imager instrument on board the Solar Dynamics Observatory and the Michelson Doppler Imager instrument on board the Solar and Heliospheric Observatory. We find remarkable similarities in the travel-time shifts measured between the methodologies applied and between the simulated and real sunspots. Forward modeling of the travel-time shifts using either Born or ray approximation kernels and the sound-speed perturbations present in the simulation indicates major disagreements with the measured travel-time shifts. These findings do not substantially change with the application of a correction for the reduction of wave amplitudes in the simulated and real sunspots. Overall, our findings demonstrate the need for new methods for inferring the subsurface structure of sunspots through helioseismic inversions.

  4. Hepatic falciform artery

    International Nuclear Information System (INIS)

    Jaques, Paul F.; Mauro, Matthew A.; Sandhu, Jeet

    1997-01-01

    The hepatic falciform artery is an occasional terminal branch of the left or middle hepatic artery, and may provide an uncommon but important collateral route when the principal visceral arteries are occluded

  5. Realistic tissue visualization using photoacoustic image

    Science.gov (United States)

    Cho, Seonghee; Managuli, Ravi; Jeon, Seungwan; Kim, Jeesu; Kim, Chulhong

    2018-02-01

    Visualization methods are very important in biomedical imaging. As a technology that understands life, biomedical imaging has the unique advantage of providing the most intuitive information in the image. This advantage of biomedical imaging can be greatly improved by choosing a special visualization method. This is more complicated in volumetric data. Volume data has the advantage of containing 3D spatial information. Unfortunately, the data itself cannot directly represent the potential value. Because images are always displayed in 2D space, visualization is the key and creates the real value of volume data. However, image processing of 3D data requires complicated algorithms for visualization and high computational burden. Therefore, specialized algorithms and computing optimization are important issues in volume data. Photoacoustic-imaging is a unique imaging modality that can visualize the optical properties of deep tissue. Because the color of the organism is mainly determined by its light absorbing component, photoacoustic data can provide color information of tissue, which is closer to real tissue color. In this research, we developed realistic tissue visualization using acoustic-resolution photoacoustic volume data. To achieve realistic visualization, we designed specialized color transfer function, which depends on the depth of the tissue from the skin. We used direct ray casting method and processed color during computing shader parameter. In the rendering results, we succeeded in obtaining similar texture results from photoacoustic data. The surface reflected rays were visualized in white, and the reflected color from the deep tissue was visualized red like skin tissue. We also implemented the CUDA algorithm in an OpenGL environment for real-time interactive imaging.

  6. Two politicians in a realistic experiment: attraction, discrepancy, intensity of delivery, and attitude change

    OpenAIRE

    Wiegman, O.

    1985-01-01

    The leader of the Socialists in the Dutch Parliament and his Liberal opponent participated in this realistic experiment. Identical TV interviews with the two politicians were recorded and shown to subjects of both parties. The intensity of delivery was also varied: emotional versus rational. Our findgins indicated that the experimental interveiw changed the attitude of the subjects. In addition, support was found for a second hypothesis: Attitude change was greater for the attractive source f...

  7. Active and realistic passive marijuana exposure tested by three immunoassays and GC/MS in urine

    Energy Technology Data Exchange (ETDEWEB)

    Mule, S.J.; Lomax, P.; Gross, S.J.

    1988-05-01

    Human urine samples obtained before and after active and passive exposure to marijuana were analyzed by immune kits (Roche, Amersham, and Syva) and gas chromatography/mass spectrometry (GC/MS). Seven of eight subjects were positive for the entire five-day test period with one immune kit. The latter correlated with GC/MS in 98% of the samples. Passive inhalation experiments under conditions likely to reflect realistic exposure resulted consistently in less than 10 ng/mL of cannabinoids. The 10-100-ng/mL cannabinoid concentration range essential for detection of occasional and moderate marijuana users is thus unaffected by realistic passive inhalation.

  8. Active and realistic passive marijuana exposure tested by three immunoassays and GC/MS in urine

    International Nuclear Information System (INIS)

    Mule, S.J.; Lomax, P.; Gross, S.J.

    1988-01-01

    Human urine samples obtained before and after active and passive exposure to marijuana were analyzed by immune kits (Roche, Amersham, and Syva) and gas chromatography/mass spectrometry (GC/MS). Seven of eight subjects were positive for the entire five-day test period with one immune kit. The latter correlated with GC/MS in 98% of the samples. Passive inhalation experiments under conditions likely to reflect realistic exposure resulted consistently in less than 10 ng/mL of cannabinoids. The 10-100-ng/mL cannabinoid concentration range essential for detection of occasional and moderate marijuana users is thus unaffected by realistic passive inhalation

  9. Double profunda brachii artery

    OpenAIRE

    Gavishiddappa A Hadimani; Jyoti V Hadimani; Ishwar B Bagoji; Shardha Bai Rathod; Balappa M Bannur

    2016-01-01

    Brachial artery (BA) is a continuation of the axillary artery at the lower border of teres major. In the cubital fossa, BA divides into radial artery and ulnar artery as terminal branches. Large branch given from the BA in the upper part is profunda brachii artery. In the present case, we noticed double profunda brachii that arises from the BA. They are profunda brachii artery 1 and profunda brachii artery 2. Profunda brachii artery 1 arises in the proximal part of the BA and profunda brachii...

  10. Realistic generation cost of solar photovoltaic electricity

    International Nuclear Information System (INIS)

    Singh, Parm Pal; Singh, Sukhmeet

    2010-01-01

    Solar photovoltaic (SPV) power plants have long working life with zero fuel cost and negligible maintenance cost but requires huge initial investment. The generation cost of the solar electricity is mainly the cost of financing the initial investment. Therefore, the generation cost of solar electricity in different years depends on the method of returning the loan. Currently levelized cost based on equated payment loan is being used. The static levelized generation cost of solar electricity is compared with the current value of variable generation cost of grid electricity. This improper cost comparison is inhibiting the growth of SPV electricity by creating wrong perception that solar electricity is very expensive. In this paper a new method of loan repayment has been developed resulting in generation cost of SPV electricity that increases with time like that of grid electricity. A generalized capital recovery factor has been developed for graduated payment loan in which capital and interest payment in each installment are calculated by treating each loan installment as an independent loan for the relevant years. Generalized results have been calculated which can be used to determine the cost of SPV electricity for a given system at different places. Results show that for SPV system with specific initial investment of 5.00 cents /kWh/year, loan period of 30 years and loan interest rate of 4% the levelized generation cost of SPV electricity with equated payment loan turns out to be 28.92 cents /kWh, while the corresponding generation cost with graduated payment loan with escalation in annual installment of 8% varies from 9.51 cents /kWh in base year to 88.63 cents /kWh in 30th year. So, in this case, the realistic current generation cost of SPV electricity is 9.51 cents /kWh and not 28.92 cents /kWh. Further, with graduated payment loan, extension in loan period results in sharp decline in cost of SPV electricity in base year. Hence, a policy change is required

  11. Determination of Realistic Fire Scenarios in Spacecraft

    Science.gov (United States)

    Dietrich, Daniel L.; Ruff, Gary A.; Urban, David

    2013-01-01

    This paper expands on previous work that examined how large a fire a crew member could successfully survive and extinguish in the confines of a spacecraft. The hazards to the crew and equipment during an accidental fire include excessive pressure rise resulting in a catastrophic rupture of the vehicle skin, excessive temperatures that burn or incapacitate the crew (due to hyperthermia), carbon dioxide build-up or accumulation of other combustion products (e.g. carbon monoxide). The previous work introduced a simplified model that treated the fire primarily as a source of heat and combustion products and sink for oxygen prescribed (input to the model) based on terrestrial standards. The model further treated the spacecraft as a closed system with no capability to vent to the vacuum of space. The model in the present work extends this analysis to more realistically treat the pressure relief system(s) of the spacecraft, include more combustion products (e.g. HF) in the analysis and attempt to predict the fire spread and limiting fire size (based on knowledge of terrestrial fires and the known characteristics of microgravity fires) rather than prescribe them in the analysis. Including the characteristics of vehicle pressure relief systems has a dramatic mitigating effect by eliminating vehicle overpressure for all but very large fires and reducing average gas-phase temperatures.

  12. Cerebral blood flow simulations in realistic geometries

    Directory of Open Access Journals (Sweden)

    Szopos Marcela

    2012-04-01

    Full Text Available The aim of this work is to perform the computation of the blood flow in all the cerebral network, obtained from medical images as angiographies. We use free finite elements codes as FreeFEM++. We first test the code on analytical solutions in simplified geometries. Then, we study the influence of boundary conditions on the flow and we finally perform first computations on realistic meshes. L’objectif est ici de simuler l’écoulement sanguin dans tout le réseau cérébral (artériel et veineux obtenu à partir d’angiographies cérébrales 3D à l’aide de logiciels d’éléments finis libres, comme FreeFEM++. Nous menons d’abord une étude détaillée des résultats sur des solutions analytiques et l’influence des conditions limites à imposer dans des géométries simplifiées avant de travailler sur les maillages réalistes.

  13. Quantifying introgression risk with realistic population genetics.

    Science.gov (United States)

    Ghosh, Atiyo; Meirmans, Patrick G; Haccou, Patsy

    2012-12-07

    Introgression is the permanent incorporation of genes from the genome of one population into another. This can have severe consequences, such as extinction of endemic species, or the spread of transgenes. Quantification of the risk of introgression is an important component of genetically modified crop regulation. Most theoretical introgression studies aimed at such quantification disregard one or more of the most important factors concerning introgression: realistic genetical mechanisms, repeated invasions and stochasticity. In addition, the use of linkage as a risk mitigation strategy has not been studied properly yet with genetic introgression models. Current genetic introgression studies fail to take repeated invasions and demographic stochasticity into account properly, and use incorrect measures of introgression risk that can be manipulated by arbitrary choices. In this study, we present proper methods for risk quantification that overcome these difficulties. We generalize a probabilistic risk measure, the so-called hazard rate of introgression, for application to introgression models with complex genetics and small natural population sizes. We illustrate the method by studying the effects of linkage and recombination on transgene introgression risk at different population sizes.

  14. Exophobic Quasi-Realistic Heterotic String Vacua

    CERN Document Server

    Assel, Benjamin; Faraggi, Alon E; Kounnas, Costas; Rizos, John

    2009-01-01

    We demonstrate the existence of heterotic-string vacua that are free of massless exotic fields. The need to break the non-Abelian GUT symmetries in k=1 heterotic-string models by Wilson lines, while preserving the GUT embedding of the weak-hypercharge and the GUT prediction sin^2\\theta_w(M(GUT))=3/8, necessarily implies that the models contain states with fractional electric charge. Such states are severely restricted by observations, and must be confined or sufficiently massive and diluted. We construct the first quasi-realistic heterotic-string models in which the exotic states do not appear in the massless spectrum, and only exist, as they must, in the massive spectrum. The SO(10) GUT symmetry is broken to the Pati-Salam subgroup. Our PS heterotic-string models contain adequate Higgs representations to break the GUT and electroweak symmetry, as well as colour Higgs triplets that can be used for the missing partner mechanism. By statistically sampling the space of Pati-Salam vacua we demonstrate the abundan...

  15. Challenges and solutions for realistic room simulation

    Science.gov (United States)

    Begault, Durand R.

    2002-05-01

    Virtual room acoustic simulation (auralization) techniques have traditionally focused on answering questions related to speech intelligibility or musical quality, typically in large volumetric spaces. More recently, auralization techniques have been found to be important for the externalization of headphone-reproduced virtual acoustic images. Although externalization can be accomplished using a minimal simulation, data indicate that realistic auralizations need to be responsive to head motion cues for accurate localization. Computational demands increase when providing for the simulation of coupled spaces, small rooms lacking meaningful reverberant decays, or reflective surfaces in outdoor environments. Auditory threshold data for both early reflections and late reverberant energy levels indicate that much of the information captured in acoustical measurements is inaudible, minimizing the intensive computational requirements of real-time auralization systems. Results are presented for early reflection thresholds as a function of azimuth angle, arrival time, and sound-source type, and reverberation thresholds as a function of reverberation time and level within 250-Hz-2-kHz octave bands. Good agreement is found between data obtained in virtual room simulations and those obtained in real rooms, allowing a strategy for minimizing computational requirements of real-time auralization systems.

  16. Realistic Scheduling Mechanism for Smart Homes

    Directory of Open Access Journals (Sweden)

    Danish Mahmood

    2016-03-01

    Full Text Available In this work, we propose a Realistic Scheduling Mechanism (RSM to reduce user frustration and enhance appliance utility by classifying appliances with respective constraints and their time of use effectively. Algorithms are proposed regarding functioning of home appliances. A 24 hour time slot is divided into four logical sub-time slots, each composed of 360 min or 6 h. In these sub-time slots, only desired appliances (with respect to appliance classification are scheduled to raise appliance utility, restricting power consumption by a dynamically modelled power usage limiter that does not only take the electricity consumer into account but also the electricity supplier. Once appliance, time and power usage limiter modelling is done, we use a nature-inspired heuristic algorithm, Binary Particle Swarm Optimization (BPSO, optimally to form schedules with given constraints representing each sub-time slot. These schedules tend to achieve an equilibrium amongst appliance utility and cost effectiveness. For validation of the proposed RSM, we provide a comparative analysis amongst unscheduled electrical load usage, scheduled directly by BPSO and RSM, reflecting user comfort, which is based upon cost effectiveness and appliance utility.

  17. Comparing Realistic Subthalamic Nucleus Neuron Models

    Science.gov (United States)

    Njap, Felix; Claussen, Jens C.; Moser, Andreas; Hofmann, Ulrich G.

    2011-06-01

    The mechanism of action of clinically effective electrical high frequency stimulation is still under debate. However, recent evidence points at the specific activation of GABA-ergic ion channels. Using a computational approach, we analyze temporal properties of the spike trains emitted by biologically realistic neurons of the subthalamic nucleus (STN) as a function of GABA-ergic synaptic input conductances. Our contribution is based on a model proposed by Rubin and Terman and exhibits a wide variety of different firing patterns, silent, low spiking, moderate spiking and intense spiking activity. We observed that most of the cells in our network turn to silent mode when we increase the GABAA input conductance above the threshold of 3.75 mS/cm2. On the other hand, insignificant changes in firing activity are observed when the input conductance is low or close to zero. We thus reproduce Rubin's model with vanishing synaptic conductances. To quantitatively compare spike trains from the original model with the modified model at different conductance levels, we apply four different (dis)similarity measures between them. We observe that Mahalanobis distance, Victor-Purpura metric, and Interspike Interval distribution are sensitive to different firing regimes, whereas Mutual Information seems undiscriminative for these functional changes.

  18. Simulation of microarray data with realistic characteristics

    Directory of Open Access Journals (Sweden)

    Lehmussola Antti

    2006-07-01

    Full Text Available Abstract Background Microarray technologies have become common tools in biological research. As a result, a need for effective computational methods for data analysis has emerged. Numerous different algorithms have been proposed for analyzing the data. However, an objective evaluation of the proposed algorithms is not possible due to the lack of biological ground truth information. To overcome this fundamental problem, the use of simulated microarray data for algorithm validation has been proposed. Results We present a microarray simulation model which can be used to validate different kinds of data analysis algorithms. The proposed model is unique in the sense that it includes all the steps that affect the quality of real microarray data. These steps include the simulation of biological ground truth data, applying biological and measurement technology specific error models, and finally simulating the microarray slide manufacturing and hybridization. After all these steps are taken into account, the simulated data has realistic biological and statistical characteristics. The applicability of the proposed model is demonstrated by several examples. Conclusion The proposed microarray simulation model is modular and can be used in different kinds of applications. It includes several error models that have been proposed earlier and it can be used with different types of input data. The model can be used to simulate both spotted two-channel and oligonucleotide based single-channel microarrays. All this makes the model a valuable tool for example in validation of data analysis algorithms.

  19. Adapting realist synthesis methodology: The case of workplace harassment interventions.

    Science.gov (United States)

    Carr, Tracey; Quinlan, Elizabeth; Robertson, Susan; Gerrard, Angie

    2017-12-01

    Realist synthesis techniques can be used to assess complex interventions by extracting and synthesizing configurations of contexts, mechanisms, and outcomes found in the literature. Our novel and multi-pronged approach to the realist synthesis of workplace harassment interventions describes our pursuit of theory to link macro and program level theories. After discovering the limitations of a dogmatic approach to realist synthesis, we adapted our search strategy and focused our analysis on a subset of data. We tailored our realist synthesis to understand how, why, and under what circumstances workplace harassment interventions are effective. The result was a conceptual framework to test our theory-based interventions and provide the basis for subsequent realist evaluation. Our experience documented in this article contributes to an understanding of how, under what circumstances, and with what consequences realist synthesis principles can be customized. Copyright © 2017 John Wiley & Sons, Ltd.

  20. Expanding subjectivities

    DEFF Research Database (Denmark)

    Lundgaard Andersen, Linda; Soldz, Stephen

    2012-01-01

    A major theme in recent psychoanalytic thinking concerns the use of therapist subjectivity, especially “countertransference,” in understanding patients. This thinking converges with and expands developments in qualitative research regarding the use of researcher subjectivity as a tool......-Saxon and continental traditions, this special issue provides examples of the use of researcher subjectivity, informed by psychoanalytic thinking, in expanding research understanding....

  1. The influence of geometric factors on the wall shear stress distribution in realistic human coronary arteries

    OpenAIRE

    Santos, Jorge André Piedade Pinhal dos

    2009-01-01

    Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para a obtenção do grau de Mestre em Engenharia Biomédica. A presente dissertação foi desenvolvida no Erasmus Medical Center em Roterdão, Holanda Background: Atherosclerosis is the main cause of death in the Western society. It is a geometrically focal disease, affecting preferentially vessel areas of low wall shear stress (SS), which induces the expression of atherogenic genes. To predict wall ...

  2. Computer model analysis of the radial artery pressure waveform.

    Science.gov (United States)

    Schwid, H A; Taylor, L A; Smith, N T

    1987-10-01

    Simultaneous measurements of aortic and radial artery pressures are reviewed, and a model of the cardiovascular system is presented. The model is based on resonant networks for the aorta and axillo-brachial-radial arterial system. The model chosen is a simple one, in order to make interpretation of the observed relationships clear. Despite its simplicity, the model produces realistic aortic and radial artery pressure waveforms. It demonstrates that the resonant properties of the arterial wall significantly alter the pressure waveform as it is propagated from the aorta to the radial artery. Although the mean and end-diastolic radial pressures are usually accurate estimates of the corresponding aortic pressures, the systolic pressure at the radial artery is often much higher than that of the aorta due to overshoot caused by the resonant behavior of the radial artery. The radial artery dicrotic notch is predominantly dependent on the axillo-brachial-radial arterial wall properties, rather than on the aortic valve or peripheral resistance. Hence the use of the radial artery dicrotic notch as an estimate of end systole is unreliable. The rate of systolic upstroke, dP/dt, of the radial artery waveform is a function of many factors, making it difficult to interpret. The radial artery waveform usually provides accurate estimates for mean and diastolic aortic pressures; for all other measurements it is an inadequate substitute for the aortic pressure waveform. In the presence of low forearm peripheral resistance the mean radial artery pressure may significantly underestimate the mean aortic pressure, as explained by a voltage divider model.

  3. To screen or not to screen for peripheral arterial disease in subjects aged 80 and over in primary health care: a cross-sectional analysis from the BELFRAIL study

    Directory of Open Access Journals (Sweden)

    Degryse Jan

    2011-05-01

    Full Text Available Abstract Background Peripheral arterial disease (PAD is common in older people. An ankle-brachial index (ABI Methods A cross-sectional study embedded within the BELFRAIL study. A general practitioner (GP centre, located in Hoeilaart, Belgium, recruited 239 patients aged 80 or older. Only three criteria for exclusion were used: urgent medical need, palliative situation and known serious dementia. The GP recorded the medical history and performed a clinical examination. The clinical research assistant performed an extensive examination including Mini-Mental State Examination (MMSE, Geriatric Depression Scale (GDS-15, Activities of Daily Living (ADL, Tinetti test and the LASA Physical Activity Questionnaire (LAPAQ. ABI was measured using an automatic oscillometric appliance. Results In 40% of patients, a reduced ABI was found. Cardiovascular risk factors were unable to identify patients with low ABI. A negative correlation was found between the number of cardiovascular morbidities and ABI. Cardiovascular morbidity had a sensitivity of 65.7% (95% CI 53.4-76.7 and a specificity of 48.6% (95% CI 38.7-58.5. Palpation of the peripheral arteries showed the highest negative predictive value (77.7% (95% CI 71.8-82.9. The LAPAQ score was significantly lower in the group with reduced ABI. Conclusion The prevalence of PAD is very high in patients aged 80 and over in general practice. The clinical examination, cardiovascular risk factors and the presence of cardiovascular morbidity were not able to identify patients with a low ABI. A screening strategy for PAD by determining ABI could be considered if effective interventions for those aged 80 and over with a low ABI become available through future research.

  4. Realistic Vascular Replicator for TAVR Procedures.

    Science.gov (United States)

    Rotman, Oren M; Kovarovic, Brandon; Sadasivan, Chander; Gruberg, Luis; Lieber, Baruch B; Bluestein, Danny

    2018-04-13

    Transcatheter aortic valve replacement (TAVR) is an over-the-wire procedure for treatment of severe aortic stenosis (AS). TAVR valves are conventionally tested using simplified left heart simulators (LHS). While those provide baseline performance reliably, their aortic root geometries are far from the anatomical in situ configuration, often overestimating the valves' performance. We report on a novel benchtop patient-specific arterial replicator designed for testing TAVR and training interventional cardiologists in the procedure. The Replicator is an accurate model of the human upper body vasculature for training physicians in percutaneous interventions. It comprises of fully-automated Windkessel mechanism to recreate physiological flow conditions. Calcified aortic valve models were fabricated and incorporated into the Replicator, then tested for performing TAVR procedure by an experienced cardiologist using the Inovare valve. EOA, pressures, and angiograms were monitored pre- and post-TAVR. A St. Jude mechanical valve was tested as a reference that is less affected by the AS anatomy. Results in the Replicator of both valves were compared to the performance in a commercial ISO-compliant LHS. The AS anatomy in the Replicator resulted in a significant decrease of the TAVR valve performance relative to the simplified LHS, with EOA and transvalvular pressures comparable to clinical data. Minor change was seen in the mechanical valve performance. The Replicator showed to be an effective platform for TAVR testing. Unlike a simplified geometric anatomy LHS, it conservatively provides clinically-relevant outcomes and complement it. The Replicator can be most valuable for testing new valves under challenging patient anatomies, physicians training, and procedural planning.

  5. Sex Differences in Cardiovascular and Subjective Stress Reactions: Prospective Evidence in a Realistic Military Setting

    Science.gov (United States)

    2014-01-01

    this study require comment. Importantly, we did not control for menstrual phase or oral contraceptive use. Reproductive hormones may be implicated in...differences in emotional and physiological responses to the Trier Social Stress Test. J Behav Ther Exp Psychiatry 39:87–98. Kirschbaum C, Pirke KM

  6. Developing Teaching Material Based on Realistic Mathematics Andoriented to the Mathematical Reasoning and Mathematical Communication

    OpenAIRE

    Habsah, Fitria

    2017-01-01

    This research aims to produce mathematics textbook for grade VII junior high school students based on realistic mathematics and oriented to the mathematical reasoning and mathematical communication. The quality is determined based on Nieveen criteria, including validity, practicality, and effectiveness.This study was a research and development and used Borg & Gall model. The subject of this research were the students of SMPN 2 Pujon-Kabupaten Malang, that is 30 students in an experimental cla...

  7. Hepatic artery aneurysms (HAAs)

    International Nuclear Information System (INIS)

    Nosratini, H.

    2004-01-01

    The hepatic artery aneurysms are rare, especially in interahepatic branches, The frequency consists of 75-80% extrahepatic and 20-25% intrahepatic. Catheterization is achieved usually from common femoral artery, other methods implemented in the case of unsuccessful catheterization from femoral artery, are translumbar and brachial catheterization. The study consist of 565 patients that were referred to the angiography ward, During seven years of assessment, five cases of hepatic artery aneurysm were found; this is a rare condition reported in the English literature. In the literature as well as in this case report the hepatic artery aneurysms are rare. In reported series the extrahepatic artery aneurysms are found more often than in the intrahepatic artery aneurysm but in this case report intrahepatic artery aneurysms are more than extrahepatic one. (author)

  8. Realist Stronghold in the Land of Thucydides? - Appraising and Resisting a Realist Tradition in Greece

    Directory of Open Access Journals (Sweden)

    Kyriakos Mikelis

    2015-10-01

    Full Text Available Given the integration of the discipline of International Relations in Greece into the global discipline since a few decades, the article addresses the reflection of the ‘realism in and for the globe’ question to this specific case. Although the argument doesn’t go as far as to ‘recover’ forgotten IR theorists or self-proclaimed realists, a geopolitical dimension of socio-economic thought during interwar addressed concerns which could be related to the intricacies of realpolitik. Then again at current times, certain scholars have been eager to maintain a firm stance in favor of realism, focusing on the work of ancient figures, especially Thucydides or Homer, and on questions of the offensive-defensive realism debate as well as on the connection with the English School, while others have offered fruitful insights matching the broad constructivist agenda. Overall, certain genuine arguments have appeared, reflecting diversified views about sovereignty and its function or mitigation.

  9. Bilateral renal artery variation

    OpenAIRE

    Üçerler, Hülya; Üzüm, Yusuf; İkiz, Z. Aslı Aktan

    2014-01-01

    Each kidney is supplied by a single renal artery, although renal artery variations are common. Variations of the renal arteryhave become important with the increasing number of renal transplantations. Numerous studies describe variations in renalartery anatomy. Especially the left renal artery is among the most critical arterial variations, because it is the referred side forresecting the donor kidney. During routine dissection in a formalin fixed male cadaver, we have found a bilateral renal...

  10. 'Semi-realistic'F-term inflation model building in supergravity

    International Nuclear Information System (INIS)

    Kain, Ben

    2008-01-01

    We describe methods for building 'semi-realistic' models of F-term inflation. By semi-realistic we mean that they are built in, and obey the requirements of, 'semi-realistic' particle physics models. The particle physics models are taken to be effective supergravity theories derived from orbifold compactifications of string theory, and their requirements are taken to be modular invariance, absence of mass terms and stabilization of moduli. We review the particle physics models, their requirements and tools and methods for building inflation models

  11. Dynamic contrast-enhanced ultrasound and transient arterial occlusion for quantification of arterial perfusion reserve in peripheral arterial disease

    International Nuclear Information System (INIS)

    Amarteifio, E.; Wormsbecher, S.; Krix, M.; Demirel, S.; Braun, S.; Delorme, S.; Böckler, D.; Kauczor, H.-U.; Weber, M.-A.

    2012-01-01

    Objective: To quantify muscular micro-perfusion and arterial perfusion reserve in peripheral arterial disease (PAD) with dynamic contrast-enhanced ultrasound (CEUS) and transient arterial occlusion. Materials and methods: This study had local institutional review board approval and written informed consent was obtained from all subjects. We examined the dominant lower leg of 40 PAD Fontaine stage IIb patients (mean age, 65 years) and 40 healthy volunteers (mean age, 54 years) with CEUS (7 MHz; MI, 0.28) during continuous intravenous infusion of 4.8 mL microbubbles. Transient arterial occlusion at mid-thigh level simulated physical exercise. With time–CEUS–intensity curves obtained from regions of interest within calf muscles, we derived the maximum CEUS signal after occlusion (max) and its time (t max ), slope to maximum (m), vascular response after occlusion (AUC post ), and analysed accuracy, receiver operating characteristic (ROC) curves, and correlations with ankle-brachial index (ABI) and walking distance. Results: All parameters differed in PAD and volunteers (p max was delayed (31.2 ± 13.6 vs. 16.7 ± 8.5 s, p post as optimal parameter combination for diagnosing PAD and therefore impaired arterial perfusion reserve. Conclusions: Dynamic CEUS with transient arterial occlusion quantifies muscular micro-perfusion and arterial perfusion reserve. The technique is accurate to diagnose PAD.

  12. Jet pump assisted artery

    Science.gov (United States)

    1975-01-01

    A procedure for priming an arterial heat pump is reported; the procedure also has a means for maintaining the pump in a primed state. This concept utilizes a capillary driven jet pump to create the necessary suction to fill the artery. Basically, the jet pump consists of a venturi or nozzle-diffuser type constriction in the vapor passage. The throat of this venturi is connected to the artery. Thus vapor, gas, liquid, or a combination of the above is pumped continuously out of the artery. As a result, the artery is always filled with liquid and an adequate supply of working fluid is provided to the evaporator of the heat pipe.

  13. Entrepreneurial Education: A Realistic Alternative for Women and Minorities.

    Science.gov (United States)

    Steward, James F.; Boyd, Daniel R.

    1989-01-01

    Entrepreneurial education is a valid, realistic occupational training alternative for minorities and women in business. Entrepreneurship requires that one become involved with those educational programs that contribute significantly to one's success. (Author)

  14. Student Work Experience: A Realistic Approach to Merchandising Education.

    Science.gov (United States)

    Horridge, Patricia; And Others

    1980-01-01

    Relevant and realistic experiences are needed to prepare the student for a future career. Addresses the results of a survey of colleges and universities in the United States in regard to their student work experience (SWE) in fashion merchandising. (Author)

  15. Development of a realistic, dynamic digital brain phantom for CT perfusion validation

    Science.gov (United States)

    Divel, Sarah E.; Segars, W. Paul; Christensen, Soren; Wintermark, Max; Lansberg, Maarten G.; Pelc, Norbert J.

    2016-03-01

    Physicians rely on CT Perfusion (CTP) images and quantitative image data, including cerebral blood flow, cerebral blood volume, and bolus arrival delay, to diagnose and treat stroke patients. However, the quantification of these metrics may vary depending on the computational method used. Therefore, we have developed a dynamic and realistic digital brain phantom upon which CTP scans can be simulated based on a set of ground truth scenarios. Building upon the previously developed 4D extended cardiac-torso (XCAT) phantom containing a highly detailed brain model, this work consisted of expanding the intricate vasculature by semi-automatically segmenting existing MRA data and fitting nonuniform rational B-spline surfaces to the new vessels. Using time attenuation curves input by the user as reference, the contrast enhancement in the vessels changes dynamically. At each time point, the iodine concentration in the arteries and veins is calculated from the curves and the material composition of the blood changes to reflect the expected values. CatSim, a CT system simulator, generates simulated data sets of this dynamic digital phantom which can be further analyzed to validate CTP studies and post-processing methods. The development of this dynamic and realistic digital phantom provides a valuable resource with which current uncertainties and controversies surrounding the quantitative computations generated from CTP data can be examined and resolved.

  16. Arterial hypertension and chronic liver disease

    DEFF Research Database (Denmark)

    Henriksen, Jens Henrik Sahl; Møller, S

    2005-01-01

    , calcitonin gene-related peptide, nitric oxide, and other vasodilators, and is most pronounced in the splanchnic area. This provides an effective (although relative) counterbalance to raised arterial blood pressure. Subjects with arterial hypertension (essential, secondary) may become normotensive during......This review looks at the alterations in the systemic haemodynamics of patients with chronic liver disease (cirrhosis) in relation to essential hypertension and arterial hypertension of renal origin. Characteristic findings in patients with cirrhosis are vasodilatation with low overall systemic...... vascular resistance, high arterial compliance, increased cardiac output, secondary activation of counterregulatory systems (renin-angiotensin-aldosterone system, sympathetic nervous system, release of vasopressin), and resistance to vasopressors. The vasodilatory state is mediated through adrenomedullin...

  17. Students' Critical Mathematical Thinking Skills and Character: Experiments for Junior High School Students through Realistic Mathematics Education Culture-Based

    Science.gov (United States)

    Palinussa, Anderson L.

    2013-01-01

    This paper presents the findings of a quasi-experimental with pre-test-post-test design and control group that aims to assess students' critical mathematical thinking skills and character through realistic mathematics education (RME) culture-based. Subjects of this study were 106 junior high school students from two low and medium schools level in…

  18. Severe gastric variceal haemorrhage due to splenic artery thrombosis and consecutive arterial bypass

    Directory of Open Access Journals (Sweden)

    Wasmuth Hermann E

    2011-06-01

    Full Text Available Abstract Background Upper gastrointestinal haemorrhage is mainly caused by ulcers. Gastric varicosis due to portal hypertension can also be held responsible for upper gastrointestinal bleeding. Portal hypertension causes the development of a collateral circulation from the portal to the caval venous system resulting in development of oesophageal and gastric fundus varices. Those may also be held responsible for upper gastrointestinal haemorrhage. Case presentation In this study, we describe the case of a 69-year-old male with recurrent severe upper gastrointestinal bleeding caused by arterial submucosal collaterals due to idiopathic splenic artery thrombosis. The diagnosis was secured using endoscopic duplex ultrasound and angiography. The patient was successfully treated with a laparoscopic splenectomy and complete dissection of the short gastric arteries, resulting in the collapse of the submucosal arteries in the gastric wall. Follow-up gastroscopy was performed on the 12th postoperative week and showed no signs of bleeding and a significant reduction in the arterial blood flow within the gastric wall. Subsequent follow-up after 6 months also showed no further gastrointestinal bleeding as well as subjective good quality of life for the patient. Conclusion Submucosal arterial collaterals must be excluded by endosonography via endoscopy in case of recurrent upper gastrointestinal bleeding. Laparoscopic splenectomy provides adequate treatment in preventing any recurrent bleeding, if gastric arterial collaterals are caused by splenic artery thrombosis.

  19. Testicular artery arising from an aberrant right renal artery | Suluba ...

    African Journals Online (AJOL)

    This case report we discovered the rare variation of the origin of the right testicular artery arising from the right aberrant renal artery with double renal artery irrigating both left and right kidneys. These variations in the testicular arteries and renal arteries have implication to surgical procedures such as orchidopexy repair for ...

  20. Martial arts training attenuates arterial stiffness in middle aged adults.

    Science.gov (United States)

    Douris, Peter C; Ingenito, Teresa; Piccirillo, Barbara; Herbst, Meredith; Petrizzo, John; Cherian, Vincen; McCutchan, Christopher; Burke, Caitlin; Stamatinos, George; Jung, Min-Kyung

    2013-09-01

    Arterial stiffness increases with age and is related to an increased risk of coronary artery disease. Poor trunk flexibility has been shown to be associated with arterial stiffness in middle-aged subjects. The purpose of our research study was to measure arterial stiffness and flexibility in healthy middle-aged martial artists compared to age and gender matched healthy sedentary controls. Ten martial artists (54.0 ± 2.0 years), who practice Soo Bahk Do (SBD), a Korean martial art, and ten sedentary subjects (54.7 ± 1.8 years) for a total of twenty subjects took part in this cross-sectional study. Arterial stiffness was assessed in all subjects using pulse wave velocity (PWV), a recognized index of arterial stiffness. Flexibility of the trunk and hamstring were also measured. The independent variables were the martial artists and matched sedentary controls. The dependent variables were PWV and flexibility. There were significant differences, between the SBD practitioners and sedentary controls, in PWV (P = 0.004), in trunk flexibility (P= 0.002), and in hamstring length (P= 0.003). The middle-aged martial artists were more flexible in their trunk and hamstrings and had less arterial stiffness compared to the healthy sedentary controls. The flexibility component of martial art training or flexibility exercises in general may be considered as a possible intervention to reduce the effects of aging on arterial stiffness.

  1. Dynamic exercise enhances regional cerebral artery mean flow velocity

    DEFF Research Database (Denmark)

    Linkis, P; Jørgensen, L G; Olesen, H L

    1995-01-01

    Dynamic exercise enhances regional cerebral artery mean flow velocity. J. Appl. Physiol. 78(1): 12-16, 1995.--Anterior (ACA) and middle (MCA) cerebral artery mean flow velocities (Vmean) and pulsatility indexes were determined using transcranial Doppler in 14 subjects during dynamic exercise afte...

  2. Arterial trauma of the extremities. An Ivorian surgical experience ...

    African Journals Online (AJOL)

    ... clinical and surgical experience of the arterial injuries of extremities for 23 years(1977 to ... Their case files have been reviewed and forms the subject of this study ... due to reperfusion injury (1 case) and biliary peritonitis(1 case). Conclusion Arterial injury is a true surgical emergencies and repair should be urgent to avoid ...

  3. Duplicated middle cerebral artery

    Science.gov (United States)

    Perez, Jesus; Machado, Calixto; Scherle, Claudio; Hierro, Daniel

    2009-01-01

    Duplicated middle cerebral artery (DMCA) is an anomalous vessel arising from the internal carotid artery. The incidence DMCA is relatively law, and an association between this anomaly and cerebral aneurysms has been documented. There is a controversy whether DMCA may have perforating arteries. This is an important fact to consider in aneurysm surgery. We report the case of a 34-year-old black woman who suffered a subarachnoid hemorrhage and the angiography a left DMCA, and an aneurysm in an inferior branch of the main MCA. The DMCA and the MCA had perforating arteries. The aneurysm was clipped without complications. The observation of perforating arteries in our patient confirms that the DMCA may have perforating arteries. This is very important to be considered in cerebral aneurysms surgery. Moreover, the DMCA may potentially serve as a collateral blood supply to the MCA territory in cases of MCA occlusion. PMID:22140405

  4. Popliteal artery entrapment syndrome.

    LENUS (Irish Health Repository)

    O'Leary, D P

    2010-01-01

    Popliteal artery entrapment syndrome is a rare abnormality of the anatomical relationship between the popliteal artery and adjacent muscles or fibrous bands in the popliteal fossa. The following is a case report of a 19 year old female, in whom popliteal artery entrapment syndrome was diagnosed, and successfully treated surgically. A review of literature is also presented and provides details on how PAES is classified, diagnosed both clinically and radiologically, and treated surgically.

  5. Realistic Real-Time Outdoor Rendering in Augmented Reality

    Science.gov (United States)

    Kolivand, Hoshang; Sunar, Mohd Shahrizal

    2014-01-01

    Realistic rendering techniques of outdoor Augmented Reality (AR) has been an attractive topic since the last two decades considering the sizeable amount of publications in computer graphics. Realistic virtual objects in outdoor rendering AR systems require sophisticated effects such as: shadows, daylight and interactions between sky colours and virtual as well as real objects. A few realistic rendering techniques have been designed to overcome this obstacle, most of which are related to non real-time rendering. However, the problem still remains, especially in outdoor rendering. This paper proposed a much newer, unique technique to achieve realistic real-time outdoor rendering, while taking into account the interaction between sky colours and objects in AR systems with respect to shadows in any specific location, date and time. This approach involves three main phases, which cover different outdoor AR rendering requirements. Firstly, sky colour was generated with respect to the position of the sun. Second step involves the shadow generation algorithm, Z-Partitioning: Gaussian and Fog Shadow Maps (Z-GaF Shadow Maps). Lastly, a technique to integrate sky colours and shadows through its effects on virtual objects in the AR system, is introduced. The experimental results reveal that the proposed technique has significantly improved the realism of real-time outdoor AR rendering, thus solving the problem of realistic AR systems. PMID:25268480

  6. Realistic real-time outdoor rendering in augmented reality.

    Directory of Open Access Journals (Sweden)

    Hoshang Kolivand

    Full Text Available Realistic rendering techniques of outdoor Augmented Reality (AR has been an attractive topic since the last two decades considering the sizeable amount of publications in computer graphics. Realistic virtual objects in outdoor rendering AR systems require sophisticated effects such as: shadows, daylight and interactions between sky colours and virtual as well as real objects. A few realistic rendering techniques have been designed to overcome this obstacle, most of which are related to non real-time rendering. However, the problem still remains, especially in outdoor rendering. This paper proposed a much newer, unique technique to achieve realistic real-time outdoor rendering, while taking into account the interaction between sky colours and objects in AR systems with respect to shadows in any specific location, date and time. This approach involves three main phases, which cover different outdoor AR rendering requirements. Firstly, sky colour was generated with respect to the position of the sun. Second step involves the shadow generation algorithm, Z-Partitioning: Gaussian and Fog Shadow Maps (Z-GaF Shadow Maps. Lastly, a technique to integrate sky colours and shadows through its effects on virtual objects in the AR system, is introduced. The experimental results reveal that the proposed technique has significantly improved the realism of real-time outdoor AR rendering, thus solving the problem of realistic AR systems.

  7. Normal variation of hepatic artery

    International Nuclear Information System (INIS)

    Kim, Inn; Nam, Myung Hyun; Rhim, Hyun Chul; Koh, Byung Hee; Seo, Heung Suk; Kim, Soon Yong

    1987-01-01

    This study was an analyses of blood supply of the liver in 125 patients who received hepatic arteriography and abdominal aortography from Jan. 1984 to Dec. 1986 at the Department of Radiology of Hanyang University Hospital. A. Variations in extrahepatic arteries: 1. The normal extrahepatic artery pattern occurred in 106 of 125 cases (84.8%) ; Right hepatic and left hepatic arteries arising from the hepatic artery proper and hepatic artery proper arising from the common hepatic artery. 2. The most common type of variation of extrahepatic artery was replaced right hepatic artery from superior mesenteric artery: 6 of 125 cases (4.8%). B. Variations in intrahepatic arteries: 1. The normal intrahepatic artery pattern occurred in 83 of 125 cases (66.4%). Right hepatic and left hepatic arteries arising from the hepatic artery proper and middle hepatic artery arising from lower portion of the umbilical point of left hepatic artery. 2. The most common variation of intrahepatic arteries was middle hepatic artery. 3. Among the variation of middle hepatic artery; Right, middle and left hepatic arteries arising from the same location at the hepatic artery proper was the most common type; 17 of 125 cases (13.6%)

  8. Renal Branch Artery Stenosis

    DEFF Research Database (Denmark)

    Andersson, Zarah; Thisted, Ebbe; Andersen, Ulrik Bjørn

    2017-01-01

    Renovascular hypertension is a common cause of pediatric hypertension. In the fraction of cases that are unrelated to syndromes such as neurofibromatosis, patients with a solitary stenosis on a branch of the renal artery are common and can be diagnostically challenging. Imaging techniques...... that perform well in the diagnosis of main renal artery stenosis may fall short when it comes to branch artery stenosis. We report 2 cases that illustrate these difficulties and show that a branch artery stenosis may be overlooked even by the gold standard method, renal angiography....

  9. Imaging the vertebral artery

    Energy Technology Data Exchange (ETDEWEB)

    Tay, Keng Yeow; U-King-Im, Jean Marie; Trivedi, Rikin A.; Higgins, Nicholas J.; Cross, Justin J.; Antoun, Nagui M. [Addenbrooke' s Hospital and University of Cambridge, Department of Radiology, Cambridge (United Kingdom); Davies, John R.; Weissberg, Peter L. [Addenbrooke' s Hospital and University of Cambridge, Division of Cardiovascular Medicine, Cambridge (United Kingdom); Gillard, Jonathan H. [Addenbrooke' s Hospital and University of Cambridge, Department of Radiology, Cambridge (United Kingdom); Addenbrooke' s Hospitald, University Department of Radiology, Cambridge (United Kingdom)

    2005-07-01

    Although conventional intraarterial digital subtraction angiography remains the gold standard method for imaging the vertebral artery, noninvasive modalities such as ultrasound, multislice computed tomographic angiography and magnetic resonance angiography are constantly improving and are playing an increasingly important role in diagnosing vertebral artery pathology in clinical practice. This paper reviews the current state of vertebral artery imaging from an evidence-based perspective. Normal anatomy, normal variants and a number of pathological entities such as vertebral atherosclerosis, arterial dissection, arteriovenous fistula, subclavian steal syndrome and vertebrobasilar dolichoectasia are discussed. (orig.)

  10. Imaging the vertebral artery

    International Nuclear Information System (INIS)

    Tay, Keng Yeow; U-King-Im, Jean Marie; Trivedi, Rikin A.; Higgins, Nicholas J.; Cross, Justin J.; Antoun, Nagui M.; Davies, John R.; Weissberg, Peter L.; Gillard, Jonathan H.

    2005-01-01

    Although conventional intraarterial digital subtraction angiography remains the gold standard method for imaging the vertebral artery, noninvasive modalities such as ultrasound, multislice computed tomographic angiography and magnetic resonance angiography are constantly improving and are playing an increasingly important role in diagnosing vertebral artery pathology in clinical practice. This paper reviews the current state of vertebral artery imaging from an evidence-based perspective. Normal anatomy, normal variants and a number of pathological entities such as vertebral atherosclerosis, arterial dissection, arteriovenous fistula, subclavian steal syndrome and vertebrobasilar dolichoectasia are discussed. (orig.)

  11. Congenital coronary artery fistula

    International Nuclear Information System (INIS)

    Oh, Yeon Hee; Kim, Hong; Zeon, Seoc Kil; Suh, Soo Jhi

    1986-01-01

    Congenital coronary artery fistula (CCAF) is communication of a coronary artery or its main branch with one of the atria or ventricles, the coronary sinus, the superior vena cava, or the pulmonary artery. In Korean peoples, only 4 cases of the CCAF were reported as rare as worldwide and authors want to report another case of CCAF, confirmed by operation. 10-year-old girl shows a fistula between sinus node artery of the right coronary artery and right atrium on root aortogram with left-to-right shunt and Qp/Qs=1.58, in which simple ligation of the sinus node artery from right coronary artery was performed. All of the 5 Korean CCAF (4 were previously reported and 1 of authors) were originated from right coronary artery, and of which 4 were opening into right ventricle and 1 of authors were into right atrium. Associated cardiac anomaly was noted in only 1 case as single coronary artery. Ages were from 9 months of age to 10 years old and no adult left case were found. 3 were female and 2 were male patients.

  12. Survey of Approaches to Generate Realistic Synthetic Graphs

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Seung-Hwan [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Lee, Sangkeun [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Powers, Sarah S [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Shankar, Mallikarjun [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Imam, Neena [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2016-10-01

    A graph is a flexible data structure that can represent relationships between entities. As with other data analysis tasks, the use of realistic graphs is critical to obtaining valid research results. Unfortunately, using the actual ("real-world") graphs for research and new algorithm development is difficult due to the presence of sensitive information in the data or due to the scale of data. This results in practitioners developing algorithms and systems that employ synthetic graphs instead of real-world graphs. Generating realistic synthetic graphs that provide reliable statistical confidence to algorithmic analysis and system evaluation involves addressing technical hurdles in a broad set of areas. This report surveys the state of the art in approaches to generate realistic graphs that are derived from fitted graph models on real-world graphs.

  13. Evaluation of photovoltaic panel temperature in realistic scenarios

    International Nuclear Information System (INIS)

    Du, Yanping; Fell, Christopher J.; Duck, Benjamin; Chen, Dong; Liffman, Kurt; Zhang, Yinan; Gu, Min; Zhu, Yonggang

    2016-01-01

    Highlights: • The developed realistic model captures more reasonably the thermal response and hysteresis effects. • The predicted panel temperature is as high as 60 °C under a solar irradiance of 1000 W/m"2 in no-wind weather. • In realistic scenarios, the thermal response normally takes 50–250 s. • The actual heating effect may cause a photoelectric efficiency drop of 2.9–9.0%. - Abstract: Photovoltaic (PV) panel temperature was evaluated by developing theoretical models that are feasible to be used in realistic scenarios. Effects of solar irradiance, wind speed and ambient temperature on the PV panel temperature were studied. The parametric study shows significant influence of solar irradiance and wind speed on the PV panel temperature. With an increase of ambient temperature, the temperature rise of solar cells is reduced. The characteristics of panel temperature in realistic scenarios were analyzed. In steady weather conditions, the thermal response time of a solar cell with a Si thickness of 100–500 μm is around 50–250 s. While in realistic scenarios, the panel temperature variation in a day is different from that in steady weather conditions due to the effect of thermal hysteresis. The heating effect on the photovoltaic efficiency was assessed based on real-time temperature measurement of solar cells in realistic weather conditions. For solar cells with a temperature coefficient in the range of −0.21%∼−0.50%, the current field tests indicated an approximate efficiency loss between 2.9% and 9.0%.

  14. Fatigue - determination of a more realistic usage factor

    International Nuclear Information System (INIS)

    Lang, H.

    2001-01-01

    The ability to use a suitable counting method for determining the stress range spectrum in elastic and simplified elastic-plastic fatigue analyses is of crucial importance for enabling determination of a realistic usage factor. Determination of elastic-plastic strain range using the K e factor from fictitious elastically calculated loads is also important in the event of elastic behaviour being exceeded. This paper thus examines both points in detail. A fatigue module with additional options, which functions on this basis is presented. The much more realistic determination of usage factor presented here offers various economic benefits depending on the application

  15. Putting a Realistic Theory of Mind into Agency Theory

    DEFF Research Database (Denmark)

    Foss, Nicolai Juul; Stea, Diego

    2014-01-01

    Agency theory is one of the most important foundational theories in management research, but it rests on contestable cognitive assumptions. Specifically, the principal is assumed to hold a perfect (correct) theory regarding some of the content of the agent's mind, while he is entirely ignorant...... concerning other such content. More realistically, individuals have some limited access to the minds of others. We explore the implications for classical agency theory of realistic assumptions regarding the human potential for interpersonal sensemaking. We discuss implications for the design and management...

  16. Elastin in large artery stiffness and hypertension

    Science.gov (United States)

    Wagenseil, Jessica E.; Mecham, Robert P.

    2012-01-01

    Large artery stiffness, as measured by pulse wave velocity (PWV), is correlated with high blood pressure and may be a causative factor in essential hypertension. The extracellular matrix components, specifically the mix of elastin and collagen in the vessel wall, determine the passive mechanical properties of the large arteries. Elastin is organized into elastic fibers in the wall during arterial development in a complex process that requires spatial and temporal coordination of numerous proteins. The elastic fibers last the lifetime of the organism, but are subject to proteolytic degradation and chemical alterations that change their mechanical properties. This review discusses how alterations in the amount, assembly, organization or chemical properties of the elastic fibers affect arterial stiffness and blood pressure. Strategies for encouraging or reversing alterations to the elastic fibers are addressed. Methods for determining the efficacy of these strategies, by measuring elastin amounts and arterial stiffness, are summarized. Therapies that have a direct effect on arterial stiffness through alterations to the elastic fibers in the wall may be an effective treatment for essential hypertension. PMID:22290157

  17. Mechanics of arterial subfailure with increasing loading rate.

    Science.gov (United States)

    Stemper, Brian D; Yoganandan, Narayan; Pintar, Frank A

    2007-01-01

    Arterial subfailure leads to delayed symptomatology and high morbidity and mortality rates, particularly for the thoracic aorta and carotid arteries. Although arterial injuries occur during high-velocity automotive collisions, previous studies of arterial subfailure focused on quasi-static loading. This investigation subjected aortic segments to increasing loading rates to quantify effects on elastic, subfailure, and ultimate vessel mechanics. Sixty-two specimens were axially distracted, and 92% demonstrated subfailure before ultimate failure. With increasing loading rate, stress at initial subfailure and ultimate failure significantly increased, and strain at initial subfailure and ultimate failure significantly decreased. Present results indicate increased susceptibility for arterial subfailure and/or dissection under higher-rate extension. According to the present results, automotive occupants are at greater risk of arterial injury under higher velocity impacts due to greater body segment motions in addition to decreased strain tolerance to subfailure and catastrophic failure.

  18. Sildenafil dilates ophthalmic artery in type 2 diabetic patients

    Directory of Open Access Journals (Sweden)

    Akeel AMH Zwain

    2013-08-01

    Full Text Available Background: Conflicting reports exist on the effect of sildenafil on ophthalmic artery blood flow; many visual disturbances due to vascular insult were reported with the use of sildenafil in diabetic patients like nonarteritic ischemic optic neuropathy. Objectives: The present work aimed to investigate whether sildenafil modulates ophthalmic artery vasoreactivity in patients with type 2 diabetes mellitus. Literature reports on this aspect are lacking. Methods: A total of 35 male subjects were enrolled in this study, 18 with type 2 diabetes mellitus matched with 17 normal individuals. Ophthalmic artery was insonated through a transorbital window using colored Doppler equipment with transcranial Doppler facility. Ophthalmic artery reactivity was assessed using breath holding/hyperventilation test, before and after giving 50 mg oral sildenafil. Results: It was found that in both normal subjects and diabetic patients, sildenafil increased baseline control of mean flow velocity of ophthalmic artery significantly (p 0.05 after sildenafil, in normal and diabetic groups. There was a significant increase of resistive index of ophthalmic artery flow in diabetic patients compared with that of normal subject (p < 0.05. Sildenafil decreased resistive index of ophthalmic artery flow significantly only in diabetic patients (p < 0.05. Conclusion: Sildenafil increased MFVopa, but had no significant effect on vasoreactivity of ophthalmic artery; sildenafil decreased resistive index only in type 2 diabetic patients.

  19. The normal distribution of thoracoabdominal aorta small branch artery ostia

    International Nuclear Information System (INIS)

    Cronin, Paul; Williams, David M.; Vellody, Ranjith; Kelly, Aine Marie; Kazerooni, Ella A.; Carlos, Ruth C.

    2011-01-01

    The purpose of this study was to determine the normal distribution of aortic branch artery ostia. CT scans of 100 subjects were retrospectively reviewed. The angular distributions of the aorta with respect to the center of the T3 to L4 vertebral bodies, and of branch artery origins with respect to the center of the aorta were measured. At each vertebral body level the distribution of intercostal/lumbar arteries and other branch arteries were calculated. The proximal descending aorta is posteriorly placed becoming a midline structure, at the thoracolumbar junction, and remains anterior to the vertebral bodies within the abdomen. The intercostal and lumbar artery ostia have a distinct distribution. At each vertebral level from T3 caudally, one intercostal artery originates from the posterior wall of the aorta throughout the thoracic aorta, while the other intercostal artery originates from the medial wall of the descending thoracic aorta high in the chest, posteromedially from the mid-thoracic aorta, and from the posterior wall of the aorta low in the chest. Mediastinal branches of the thoracic aorta originate from the medial and anterior wall. Lumbar branches originate only from the posterior wall of the abdominal aorta. Aortic branch artery origins arise with a bimodal distribution and have a characteristic location. Mediastinal branches of the thoracic aorta originate from the medial and anterior wall. Knowing the location of aortic branch artery ostia may help distinguish branch artery pseudoaneurysms from penetrating ulcers.

  20. Pulmonary artery aneurysm

    African Journals Online (AJOL)

    Enrique

    Introduction. Pulmonary artery aneurysms are a rare finding in general radiological practice. The possible causes are myriad and diverse in pathophysiolo- gy. Patients with post-stenotic dilata- tion of the main pulmonary artery usually present fairly late with insidi- ous cardiorespiratory symptoms. Diagnosis requires ...

  1. BILATERAL DUPLICATION OF RENAL ARTERIES

    OpenAIRE

    Prajkta A Thete; Mehera Bhoir; M.V.Ambiye

    2014-01-01

    Routine dissection of a male cadaver revealed the presence of bilateral double renal arteries. On the right side the accessory renal artery originated from the abdominal aorta just above the main renal artery. On the left side the accessory renal artery originated from the abdominal aorta about 1 cm above the main renal artery. Knowledge of the variations of renal vascular anatomy has importance in exploration and treatment of renal trauma, renal transplantation, renal artery embolization, su...

  2. Bilateral triple renal arteries

    International Nuclear Information System (INIS)

    Pestemalci, Turan; Yildiz, Yusuf Zeki; Yildirim, Mehmet; Mavi, Ayfer; Gumusburun, Erdem

    2009-01-01

    Knowledge of the variations of the renal artery has grown in importance with increasing numbers of renal transplants, vascular reconstructions and various surgical and radio logic techniques being performed in recent years. We report the presence of bilateral triple renal arteries, discovered on routine dissection of a male cadaver. On the right side, one additional renal artery originated from the abdominal aorta (distributed to superior pole of the kidney) and one other originated from the right common iliac artery (distributed to lower pole of the kidney). On the left side, both additional renal arteries originated from the abdominal aorta. Our observation has been compared with variations described in the literature and their clinical importance has been emphasized. (author)

  3. Occlusion of Heubner's artery

    International Nuclear Information System (INIS)

    Sato, Manabu; Kidooka, Minoru

    1982-01-01

    A case of occlusion of the left Heubner's artery in a right-handed, 51-year-old man is reported. Cardinal clinical features were transient right hemiparesis and mental disturbance, especially intellectual defect. Low density areas were found at CT in the globus pallidus, putamen, anterior limb of the internal capsule and a part of the caudate nucleus. It is well known that the occlusion of the Heubner's artery causes transient motor paresis of upper extremity on the contralaterl side. However, in the case where the Heubner's artery is remarkably well developed when compared with the medial striate arteries as was the case in this patient, it should be noted that the occlusion of the Heubner's artery may well causes grave mental disturbance, in addition. (author)

  4. A possible definition of a {\\it Realistic} Physics Theory

    OpenAIRE

    Gisin, Nicolas

    2014-01-01

    A definition of a {\\it Realistic} Physics Theory is proposed based on the idea that, at all time, the set of physical properties possessed (at that time) by a system should unequivocally determine the probabilities of outcomes of all possible measurements.

  5. Evaluation of Highly Realistic Training for Independent Duty Corpsmen Students

    Science.gov (United States)

    2015-05-21

    that he or she can perform desired actions or behaviors ( Bandura , 1977). In the present study, three types of self-efficacy were assessed: general...such as resilience. IDC Highly Realistic Training 10 REFERENCES Bandura , A (1977). Self-efficacy: Toward a unifying theory of behavioral

  6. Using a Realist Research Methodology in Policy Analysis

    Science.gov (United States)

    Lourie, Megan; Rata, Elizabeth

    2017-01-01

    The article describes the usefulness of a realist methodology in linking sociological theory to empirically obtained data through the development of a methodological device. Three layers of analysis were integrated: 1. the findings from a case study about Maori language education in New Zealand; 2. the identification and analysis of contradictions…

  7. Automated Finger Spelling by Highly Realistic 3D Animation

    Science.gov (United States)

    Adamo-Villani, Nicoletta; Beni, Gerardo

    2004-01-01

    We present the design of a new 3D animation tool for self-teaching (signing and reading) finger spelling the first basic component in learning any sign language. We have designed a highly realistic hand with natural animation of the finger motions. Smoothness of motion (in real time) is achieved via programmable blending of animation segments. The…

  8. Creating a Realistic Context for Team Projects in HCI

    NARCIS (Netherlands)

    Koppelman, Herman; van Dijk, Betsy

    2006-01-01

    Team projects are nowadays common practice in HCI education. This paper focuses on the role of clients and users in team projects in introductory HCI courses. In order to provide projects with a realistic context we invite people from industry to serve as clients for the student teams. Some of them

  9. Generalized Warburg impedance on realistic self-affine fractals ...

    Indian Academy of Sciences (India)

    Administrator

    Generalized Warburg impedance on realistic self-affine fractals: Comparative study of statistically corrugated and isotropic roughness. RAJESH KUMAR and RAMA KANT. Journal of Chemical Sciences, Vol. 121, No. 5, September 2009, pp. 579–588. 1. ( ) c. L. R ω on page 582, column 2, para 2, after eq (8) should read as ...

  10. Numerical computation of aeroacoustic transfer functions for realistic airfoils

    NARCIS (Netherlands)

    De Santana, Leandro Dantas; Miotto, Renato Fuzaro; Wolf, William Roberto

    2017-01-01

    Based on Amiet's theory formalism, we propose a numerical framework to compute the aeroacoustic transfer function of realistic airfoil geometries. The aeroacoustic transfer function relates the amplitude and phase of an incoming periodic gust to the respective unsteady lift response permitting,

  11. An Overview of Westinghouse Realistic Large Break LOCA Evaluation Model

    Directory of Open Access Journals (Sweden)

    Cesare Frepoli

    2008-01-01

    Full Text Available Since the 1988 amendment of the 10 CFR 50.46 rule in 1988, Westinghouse has been developing and applying realistic or best-estimate methods to perform LOCA safety analyses. A realistic analysis requires the execution of various realistic LOCA transient simulations where the effect of both model and input uncertainties are ranged and propagated throughout the transients. The outcome is typically a range of results with associated probabilities. The thermal/hydraulic code is the engine of the methodology but a procedure is developed to assess the code and determine its biases and uncertainties. In addition, inputs to the simulation are also affected by uncertainty and these uncertainties are incorporated into the process. Several approaches have been proposed and applied in the industry in the framework of best-estimate methods. Most of the implementations, including Westinghouse, follow the Code Scaling, Applicability and Uncertainty (CSAU methodology. Westinghouse methodology is based on the use of the WCOBRA/TRAC thermal-hydraulic code. The paper starts with an overview of the regulations and its interpretation in the context of realistic analysis. The CSAU roadmap is reviewed in the context of its implementation in the Westinghouse evaluation model. An overview of the code (WCOBRA/TRAC and methodology is provided. Finally, the recent evolution to nonparametric statistics in the current edition of the W methodology is discussed. Sample results of a typical large break LOCA analysis for a PWR are provided.

  12. Empirical Evidence for Niss' "Implemented Anticipation" in Mathematising Realistic Situations

    Science.gov (United States)

    Stillman, Gloria; Brown, Jill P.

    2012-01-01

    Mathematisation of realistic situations is an on-going focus of research. Classroom data from a Year 9 class participating in a program of structured modelling of real situations was analysed for evidence of Niss's theoretical construct, implemented anticipation, during mathematisation. Evidence was found for two of three proposed aspects. In…

  13. Nuclear properties with realistic Hamiltonians through spectral distribution theory

    International Nuclear Information System (INIS)

    Vary, J.P.; Belehrad, R.; Dalton, B.J.

    1979-01-01

    Motivated by the need of non-perturbative methods for utilizing realistic nuclear Hamiltonians H, the authors use spectral distribution theory, based on calculated moments of H, to obtain specific bulk and valence properties of finite nuclei. The primary emphasis here is to present results for the binding energies of nuclei obtained with and without an assumed core. (Auth.)

  14. Two-Capacitor Problem: A More Realistic View.

    Science.gov (United States)

    Powell, R. A.

    1979-01-01

    Discusses the two-capacitor problem by considering the self-inductance of the circuit used and by determining how well the usual series RC circuit approximates the two-capacitor problem when realistic values of L, C, and R are chosen. (GA)

  15. Rethinking Mathematics Teaching in Liberia: Realistic Mathematics Education

    Science.gov (United States)

    Stemn, Blidi S.

    2017-01-01

    In some African cultures, the concept of division does not necessarily mean sharing money or an item equally. How an item is shared might depend on the ages of the individuals involved. This article describes the use of the Realistic Mathematics Education (RME) approach to teach division word problems involving money in a 3rd-grade class in…

  16. Improving Mathematics Teaching in Kindergarten with Realistic Mathematical Education

    Science.gov (United States)

    Papadakis, Stamatios; Kalogiannakis, Michail; Zaranis, Nicholas

    2017-01-01

    The present study investigates and compares the influence of teaching Realistic Mathematics on the development of mathematical competence in kindergarten. The sample consisted of 231 Greek kindergarten students. For the implementation of the survey, we conducted an intervention, which included one experimental and one control group. Children in…

  17. Towards a Realist Sociology of Education: A Polyphonic Review Essay

    Science.gov (United States)

    Grenfell, Michael; Hood, Susan; Barrett, Brian D.; Schubert, Dan

    2017-01-01

    This review essay evaluates Karl Maton's "Knowledge and Knowers: Towards a Realist Sociology of Education" as a recent examination of the sociological causes and effects of education in the tradition of the French social theorist Pierre Bourdieu and the British educational sociologist Basil Bernstein. Maton's book synthesizes the…

  18. Principles of maximally classical and maximally realistic quantum ...

    Indian Academy of Sciences (India)

    Principles of maximally classical and maximally realistic quantum mechanics. S M ROY. Tata Institute of Fundamental Research, Homi Bhabha Road, Mumbai 400 005, India. Abstract. Recently Auberson, Mahoux, Roy and Singh have proved a long standing conjecture of Roy and Singh: In 2N-dimensional phase space, ...

  19. Place of a Realistic Teacher Education Pedagogy in an ICT ...

    African Journals Online (AJOL)

    This article is based on a study undertaken to examine the impact of introducing a realistic teacher education pedagogy (RTEP) oriented learning environment supported by ICT on distance teacher education in Uganda. It gives an overview of the quality, quantity and training of teachers in primary and secondary schools

  20. Elements of a realistic 17 GHz FEL/TBA design

    International Nuclear Information System (INIS)

    Hopkins, D.B.; Halbach, K.; Hoyer, E.H.; Sessler, A.M.; Sternbach, E.J.

    1989-01-01

    Recently, renewed interest in an FEL version of a two-beam accelerator (TBA) has prompted a study of practical system and structure designs for achieving the specified physics goals. This paper presents elements of a realistic design for an FEL/TBA suitable for a 1 TeV, 17 GHz linear collider. 13 refs., 8 figs., 2 tabs

  1. International Management: Creating a More Realistic Global Planning Environment.

    Science.gov (United States)

    Waldron, Darryl G.

    2000-01-01

    Discusses the need for realistic global planning environments in international business education, introducing a strategic planning model that has teams interacting with teams to strategically analyze a selected multinational company. This dynamic process must result in a single integrated written analysis that specifies an optimal strategy for…

  2. Realist synthesis: illustrating the method for implementation research

    Directory of Open Access Journals (Sweden)

    Rycroft-Malone Jo

    2012-04-01

    Full Text Available Abstract Background Realist synthesis is an increasingly popular approach to the review and synthesis of evidence, which focuses on understanding the mechanisms by which an intervention works (or not. There are few published examples of realist synthesis. This paper therefore fills a gap by describing, in detail, the process used for a realist review and synthesis to answer the question ‘what interventions and strategies are effective in enabling evidence-informed healthcare?’ The strengths and challenges of conducting realist review are also considered. Methods The realist approach involves identifying underlying causal mechanisms and exploring how they work under what conditions. The stages of this review included: defining the scope of the review (concept mining and framework formulation; searching for and scrutinising the evidence; extracting and synthesising the evidence; and developing the narrative, including hypotheses. Results Based on key terms and concepts related to various interventions to promote evidence-informed healthcare, we developed an outcome-focused theoretical framework. Questions were tailored for each of four theory/intervention areas within the theoretical framework and were used to guide development of a review and data extraction process. The search for literature within our first theory area, change agency, was executed and the screening procedure resulted in inclusion of 52 papers. Using the questions relevant to this theory area, data were extracted by one reviewer and validated by a second reviewer. Synthesis involved organisation of extracted data into evidence tables, theming and formulation of chains of inference, linking between the chains of inference, and hypothesis formulation. The narrative was developed around the hypotheses generated within the change agency theory area. Conclusions Realist synthesis lends itself to the review of complex interventions because it accounts for context as well as

  3. Middle cerebral artery blood velocity during running

    DEFF Research Database (Denmark)

    Lyngeraa, Tobias; Pedersen, Lars Møller; Mantoni, T

    2013-01-01

    for eight subjects, respectively, were excluded from analysis because of insufficient signal quality. Running increased mean arterial pressure and mean MCA velocity and induced rhythmic oscillations in BP and in MCA velocity corresponding to the difference between step rate and heart rate (HR) frequencies....... During running, rhythmic oscillations in arterial BP induced by interference between HR and step frequency impact on cerebral blood velocity. For the exercise as a whole, average MCA velocity becomes elevated. These results suggest that running not only induces an increase in regional cerebral blood flow...

  4. Plasma levels of the arterial wall protein fibulin-1 are associated with carotid-femoral pulse wave velocity

    DEFF Research Database (Denmark)

    Laugesen, Esben; Høyem, Pernille; Christiansen, Jens Sandahl

    2013-01-01

    The arterial system in diabetic patients is characterized by generalized non-atherosclerotic alterations in the vascular extracellular matrix causing increased arterial stiffness compared with subjects without diabetes. The underlying pathophysiology remains elusive. The elastin-associated extrac......The arterial system in diabetic patients is characterized by generalized non-atherosclerotic alterations in the vascular extracellular matrix causing increased arterial stiffness compared with subjects without diabetes. The underlying pathophysiology remains elusive. The elastin...

  5. The effect of problem posing and problem solving with realistic mathematics education approach to the conceptual understanding and adaptive reasoning

    Science.gov (United States)

    Mahendra, Rengga; Slamet, Isnandar; Budiyono

    2017-12-01

    One of the difficulties of students in learning mathematics is on the subject of geometry that requires students to understand abstract things. The aim of this research is to determine the effect of learning model Problem Posing and Problem Solving with Realistic Mathematics Education Approach to conceptual understanding and students' adaptive reasoning in learning mathematics. This research uses a kind of quasi experimental research. The population of this research is all seventh grade students of Junior High School 1 Jaten, Indonesia. The sample was taken using stratified cluster random sampling technique. The test of the research hypothesis was analyzed by using t-test. The results of this study indicate that the model of Problem Posing learning with Realistic Mathematics Education Approach can improve students' conceptual understanding significantly in mathematics learning. In addition tu, the results also showed that the model of Problem Solving learning with Realistic Mathematics Education Approach can improve students' adaptive reasoning significantly in learning mathematics. Therefore, the model of Problem Posing and Problem Solving learning with Realistic Mathematics Education Approach is appropriately applied in mathematics learning especially on the subject of geometry so as to improve conceptual understanding and students' adaptive reasoning. Furthermore, the impact can improve student achievement.

  6. Renal artery stenosis

    International Nuclear Information System (INIS)

    Desberg, A.; Paushter, D.M.; Lammert, G.K.; Hale, J.; Troy, R.; Novic, A.; Nally, J. Jr.

    1989-01-01

    Renal artery disease is a potentially correctable cause of hypertension. Previous studies have suggested the utility of duplex sonography in accurately detecting and grading the severity of renal artery stenosis. The purpose of this paper is to evaluate color flow Doppler for this use. Forty-three kidneys were examined by color-flow Doppler and conventional duplex sampling in patients with suspected renovascular hypertension or those undergoing aortography for unrelated reasons. Doppler tracings were obtained from the renal arteries and aorta with calculation of the renal aortic ratio (RAR) and resistive index (RI). Results of Doppler sampling with color flow guidance were compared with aortograms in a blinded fashion

  7. Coronary artery aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Koischwitz, D.; Harder, T.; Schuppan, U.; Thurn, P.

    1982-04-01

    Seven saccular coronary artery aneurysms have been demonstrated in the course of 1452 selective coronary artery angiograms. In six patients they were arterio-sclerotic; in one patient the aneurysm must have been congenital or of mycotic-embolic origin. The differential diagnosis between true aneurysms and other causes of vascular dilatation is discussed. Coronary artery aneurysms have a poor prognosis because of the possibility of rupture with resultant cardiac tamponade, or the development of thrombo-embolic myocardial infarction. These aneurysms can only be diagnosed by means of coronary angiography and require appropriate treatment.

  8. Vertebrobasilar Artery Occlusion

    Directory of Open Access Journals (Sweden)

    Schoen, Jessica

    2011-05-01

    Full Text Available The presentation of vertebrobasilar artery occlusion varies with the cause of occlusion and location of ischemia. This often results in delay in diagnosis. Areas of the brain supplied by the posterior circulation are difficult to visualize and usually require angiography or magnetic resonance imaging. Intravenous thrombolysis and local-intra arterial thrombolysis are the most common treatment approaches used. Recanalization of the occluded vessel significantly improves morbidity and mortality. Here we present a review of the literature and a case of a patient with altered mental status caused by vertebrobasilar artery occlusion. [West J Emerg Med. 2011;12(2:233-239.

  9. Normal and Pathological NCAT Image and Phantom Data Based on Physiologically Realistic Left Ventricle Finite-Element Models

    International Nuclear Information System (INIS)

    Veress, Alexander I.; Segars, W. Paul; Weiss, Jeffrey A.; Tsui, Benjamin M.W.; Gullberg, Grant T.

    2006-01-01

    The 4D NURBS-based Cardiac-Torso (NCAT) phantom, which provides a realistic model of the normal human anatomy and cardiac and respiratory motions, is used in medical imaging research to evaluate and improve imaging devices and techniques, especially dynamic cardiac applications. One limitation of the phantom is that it lacks the ability to accurately simulate altered functions of the heart that result from cardiac pathologies such as coronary artery disease (CAD). The goal of this work was to enhance the 4D NCAT phantom by incorporating a physiologically based, finite-element (FE) mechanical model of the left ventricle (LV) to simulate both normal and abnormal cardiac motions. The geometry of the FE mechanical model was based on gated high-resolution x-ray multi-slice computed tomography (MSCT) data of a healthy male subject. The myocardial wall was represented as transversely isotropichyperelastic material, with the fiber angle varying from -90 degrees at the epicardial surface, through 0 degrees at the mid-wall, to 90 degrees at the endocardial surface. A time varying elastance model was used to simulate fiber contraction, and physiological intraventricular systolic pressure-time curves were applied to simulate the cardiac motion over the entire cardiac cycle. To demonstrate the ability of the FE mechanical model to accurately simulate the normal cardiac motion as well abnormal motions indicative of CAD, a normal case and two pathologic cases were simulated and analyzed. In the first pathologic model, a subendocardial anterior ischemic region was defined. A second model was created with a transmural ischemic region defined in the same location. The FE based deformations were incorporated into the 4D NCAT cardiac model through the control points that define the cardiac structures in the phantom which were set to move according to the predictions of the mechanical model. A simulation study was performed using the FE-NCAT combination to investigate how the

  10. PIV-measured versus CFD-predicted flow dynamics in anatomically realistic cerebral aneurysm models.

    Science.gov (United States)

    Ford, Matthew D; Nikolov, Hristo N; Milner, Jaques S; Lownie, Stephen P; Demont, Edwin M; Kalata, Wojciech; Loth, Francis; Holdsworth, David W; Steinman, David A

    2008-04-01

    Computational fluid dynamics (CFD) modeling of nominally patient-specific cerebral aneurysms is increasingly being used as a research tool to further understand the development, prognosis, and treatment of brain aneurysms. We have previously developed virtual angiography to indirectly validate CFD-predicted gross flow dynamics against the routinely acquired digital subtraction angiograms. Toward a more direct validation, here we compare detailed, CFD-predicted velocity fields against those measured using particle imaging velocimetry (PIV). Two anatomically realistic flow-through phantoms, one a giant internal carotid artery (ICA) aneurysm and the other a basilar artery (BA) tip aneurysm, were constructed of a clear silicone elastomer. The phantoms were placed within a computer-controlled flow loop, programed with representative flow rate waveforms. PIV images were collected on several anterior-posterior (AP) and lateral (LAT) planes. CFD simulations were then carried out using a well-validated, in-house solver, based on micro-CT reconstructions of the geometries of the flow-through phantoms and inlet/outlet boundary conditions derived from flow rates measured during the PIV experiments. PIV and CFD results from the central AP plane of the ICA aneurysm showed a large stable vortex throughout the cardiac cycle. Complex vortex dynamics, captured by PIV and CFD, persisted throughout the cardiac cycle on the central LAT plane. Velocity vector fields showed good overall agreement. For the BA, aneurysm agreement was more compelling, with both PIV and CFD similarly resolving the dynamics of counter-rotating vortices on both AP and LAT planes. Despite the imposition of periodic flow boundary conditions for the CFD simulations, cycle-to-cycle fluctuations were evident in the BA aneurysm simulations, which agreed well, in terms of both amplitudes and spatial distributions, with cycle-to-cycle fluctuations measured by PIV in the same geometry. The overall good agreement

  11. WE-D-18A-05: Construction of Realistic Liver Phantoms From Patient Images and a Commercial 3D Printer

    International Nuclear Information System (INIS)

    Leng, S; Vrieze, T; Kuhlmann, J; Yu, L; Matsumoto, J; Morris, J; McCollough, C

    2014-01-01

    Purpose: To assess image quality and radiation dose reduction in abdominal CT imaging, physical phantoms having realistic background textures and lesions are highly desirable. The purpose of this work was to construct a liver phantom with realistic background and lesions using patient CT images and a 3D printer. Methods: Patient CT images containing liver lesions were segmented into liver tissue, contrast-enhanced vessels, and liver lesions using commercial software (Mimics, Materialise, Belgium). Stereolithography (STL) files of each segmented object were created and imported to a 3D printer (Object350 Connex, Stratasys, MN). After test scans were performed to map the eight available printing materials into CT numbers, printing materials were assigned to each object and a physical liver phantom printed. The printed phantom was scanned on a clinical CT scanner and resulting images were compared with the original patient CT images. Results: The eight available materials used to print the liver phantom had CT number ranging from 62 to 117 HU. In scans of the liver phantom, the liver lesions and veins represented in the STL files were all visible. Although the absolute value of the CT number in the background liver material (approx. 85 HU) was higher than in patients (approx. 40 HU), the difference in CT numbers between lesions and background were representative of the low contrast values needed for optimization tasks. Future work will investigate materials with contrast sufficient to emulate contrast-enhanced arteries. Conclusion: Realistic liver phantoms can be constructed from patient CT images using a commercial 3D printer. This technique may provide phantoms able to determine the effect of radiation dose reduction and noise reduction techniques on the ability to detect subtle liver lesions in the context of realistic background textures

  12. WE-D-18A-05: Construction of Realistic Liver Phantoms From Patient Images and a Commercial 3D Printer

    Energy Technology Data Exchange (ETDEWEB)

    Leng, S; Vrieze, T; Kuhlmann, J; Yu, L; Matsumoto, J; Morris, J; McCollough, C [Mayo Clinic, Rochester, MN (United States)

    2014-06-15

    Purpose: To assess image quality and radiation dose reduction in abdominal CT imaging, physical phantoms having realistic background textures and lesions are highly desirable. The purpose of this work was to construct a liver phantom with realistic background and lesions using patient CT images and a 3D printer. Methods: Patient CT images containing liver lesions were segmented into liver tissue, contrast-enhanced vessels, and liver lesions using commercial software (Mimics, Materialise, Belgium). Stereolithography (STL) files of each segmented object were created and imported to a 3D printer (Object350 Connex, Stratasys, MN). After test scans were performed to map the eight available printing materials into CT numbers, printing materials were assigned to each object and a physical liver phantom printed. The printed phantom was scanned on a clinical CT scanner and resulting images were compared with the original patient CT images. Results: The eight available materials used to print the liver phantom had CT number ranging from 62 to 117 HU. In scans of the liver phantom, the liver lesions and veins represented in the STL files were all visible. Although the absolute value of the CT number in the background liver material (approx. 85 HU) was higher than in patients (approx. 40 HU), the difference in CT numbers between lesions and background were representative of the low contrast values needed for optimization tasks. Future work will investigate materials with contrast sufficient to emulate contrast-enhanced arteries. Conclusion: Realistic liver phantoms can be constructed from patient CT images using a commercial 3D printer. This technique may provide phantoms able to determine the effect of radiation dose reduction and noise reduction techniques on the ability to detect subtle liver lesions in the context of realistic background textures.

  13. [Endarterectomy of the coronary arteries].

    Science.gov (United States)

    Fischer, V; Simkovic, I; Holoman, M; Verchvodko, P; Janotík, P; Galbánek, J; Hulman, M; Kostelnicák, J; Jurco, R; Slezák, J

    1992-02-01

    The authors analyze 50 patients with endarterectomy of the coronary arteries during the periods of 1972-1974 and 1988-1990. The results of endarterectomy of the right and left coronary artery provide evidence of its justification in indicated cases whereby contrary to some departments the results of endarterectomy of the left coronary artery are comparable with endarterectomy of the right coronary artery.

  14. Compas project stress analysis of HLW containers: behaviour under realistic disposal conditions

    International Nuclear Information System (INIS)

    Ove Arup and Partners, London

    1990-01-01

    The Compas project is concerned with the structural performance of metal overpacks which may be used to encapsulate vitrified high-level waste (HLW) forms before disposal in deep geological repositories. In this final stage of the project, analysis of an HLW overpack of realistic design is performed to predict its behaviour when subjected to likely repository loads. This analysis work is undertaken with the benefit of experience gained in previous phases of the project in which the ability to accurately predict overpack behaviour, when subjected to a uniform external pressure, was demonstrated. Burial in clay, granite and salt environments has been considered and two distinct loading arrangements identified, in an attempt to represent the worst conditions that could be imposed by such media. The analysis successfully demonstrates the ability of the containers to withstand extreme, yet credible, repository loads

  15. Popliteal Arterial Aneurysms

    African Journals Online (AJOL)

    plication was acute arterial occlusion caused by thrombo- embolism. The reasons for ... Total. 43. 55. TABLE 11. CONCOMITANT DISEASE IN 38 PATIENTS .... Dacron prosthesis in 4. .... genous saphenous vein and the type of anastomosis.

  16. Coronary artery fistula

    Science.gov (United States)

    ... PA: Elsevier Saunders; 2015:chap 84. Friedman AH, Silverman NH. Congenital anomalies of the coronary arteries. In: ... provided by VeriMed Healthcare Network. Also reviewed by David Zieve, MD, MHA, Isla Ogilvie, PhD, and the ...

  17. Realistic Visualization of Virtual Views and Virtual Cinema

    DEFF Research Database (Denmark)

    Livatino, Salvatore

    2005-01-01

    Realistic Virtual View Visualization is a new field of research which has received increasing attention in recent years. It is strictly related to the increased popularity of virtual reality and the spread of its applications, among which virtual photography and cinematography. The use of computer...... generated characters, "virtual actors", in the motion picture production increases every day. While the most known computer graphics techniques have largely been adopted successfully in nowadays fictions, it still remains very challenging to implement virtual actors which would resemble, visually, human...... beings. Interestingly, film directors have been looking at the recent progress achieved by the research community in the field of realistic visualization of virtual views, and they have successfully implemented state of the art research approaches in their productions. An innovative concept...

  18. Photo-Realistic Image Synthesis and Virtual Cinematography

    DEFF Research Database (Denmark)

    Livatino, Salvatore

    2005-01-01

    Realistic Virtual View Synthesis is a new field of research that has received increasing attention in recent years. It is strictly related to the grown popularity of virtual reality and the spread of its applications, among which virtual photography and cinematography. The use of computer generated...... characters, "virtual actors", in the motion picture production increases every day. While the most known computer graphics techniques have largely been adopted successfully in nowadays fictions, it still remains very challenging to implement virtual actors which would resemble, visually, human beings....... Interestingly, film directors have been looking at the recent progress achieved by the research community in the field of realistic visualization of virtual views, and they have successfully implemented state of the art research approaches in their productions. An innovative concept is then gaining consensus...

  19. Interferometric data modelling: issues in realistic data generation

    International Nuclear Information System (INIS)

    Mukherjee, Soma

    2004-01-01

    This study describes algorithms developed for modelling interferometric noise in a realistic manner, i.e. incorporating non-stationarity that can be seen in the data from the present generation of interferometers. The noise model is based on individual component models (ICM) with the application of auto regressive moving average (ARMA) models. The data obtained from the model are vindicated by standard statistical tests, e.g. the KS test and Akaike minimum criterion. The results indicate a very good fit. The advantage of using ARMA for ICMs is that the model parameters can be controlled and hence injection and efficiency studies can be conducted in a more controlled environment. This realistic non-stationary noise generator is intended to be integrated within the data monitoring tool framework

  20. Role-playing for more realistic technical skills training.

    Science.gov (United States)

    Nikendei, C; Zeuch, A; Dieckmann, P; Roth, C; Schäfer, S; Völkl, M; Schellberg, D; Herzog, W; Jünger, J

    2005-03-01

    Clinical skills are an important and necessary part of clinical competence. Simulation plays an important role in many fields of medical education. Although role-playing is common in communication training, there are no reports about the use of student role-plays in the training of technical clinical skills. This article describes an educational intervention with analysis of pre- and post-intervention self-selected student survey evaluations. After one term of skills training, a thorough evaluation showed that the skills-lab training did not seem very realistic nor was it very demanding for trainees. To create a more realistic training situation and to enhance students' involvement, case studies and role-plays with defined roles for students (i.e. intern, senior consultant) were introduced into half of the sessions. Results of the evaluation in the second term showed that sessions with role-playing were rated significantly higher than sessions without role-playing.

  1. Realistic minimum accident source terms - Evaluation, application, and risk acceptance

    International Nuclear Information System (INIS)

    Angelo, P. L.

    2009-01-01

    The evaluation, application, and risk acceptance for realistic minimum accident source terms can represent a complex and arduous undertaking. This effort poses a very high impact to design, construction cost, operations and maintenance, and integrated safety over the expected facility lifetime. At the 2005 Nuclear Criticality Safety Division (NCSD) Meeting in Knoxville Tenn., two papers were presented mat summarized the Y-12 effort that reduced the number of criticality accident alarm system (CAAS) detectors originally designed for the new Highly Enriched Uranium Materials Facility (HEUMF) from 258 to an eventual as-built number of 60. Part of that effort relied on determining a realistic minimum accident source term specific to the facility. Since that time, the rationale for an alternate minimum accident has been strengthened by an evaluation process that incorporates realism. A recent update to the HEUMF CAAS technical basis highlights the concepts presented here. (authors)

  2. Realistic electricity market simulator for energy and economic studies

    International Nuclear Information System (INIS)

    Bernal-Agustin, Jose L.; Contreras, Javier; Conejo, Antonio J.; Martin-Flores, Raul

    2007-01-01

    Electricity market simulators have become a useful tool to train engineers in the power industry. With the maturing of electricity markets throughout the world, there is a need for sophisticated software tools that can replicate the actual behavior of power markets. In most of these markets, power producers/consumers submit production/demand bids and the Market Operator clears the market producing a single price per hour. What makes markets different from each other are the bidding rules and the clearing algorithms to balance the market. This paper presents a realistic simulator of the day-ahead electricity market of mainland Spain. All the rules that govern this market are modeled. This simulator can be used either to train employees by power companies or to teach electricity markets courses in universities. To illustrate the tool, several realistic case studies are presented and discussed. (author)

  3. Facilities upgrade for natural forces: traditional vs. realistic approach

    International Nuclear Information System (INIS)

    Terkun, V.

    1985-01-01

    The traditional method utilized for upgrading existing buildings and equipment involves the following steps: performs structural study using finite element analysis and some in situ testing; compare predicted member forces/stresses to material code allowables; determine strengthening schemes for those structural members judged to be weak; estimate cost for required upgrades. This approach will result in structural modifications that are not only conservative but very expensive as well. The realistic structural evaluation approach uses traditional data to predict structural weaknesses as a final step. Next, using considerable information now available for buildings and equipment exposed to natural hazards, engineering judgments about structures being evaluated can be made with a great deal of confidence. This approach does not eliminate conservatism entirely, but it does reduce it to a reasonable and realistic level. As a result, the upgrade cost goes down without compromising the low risk necessary for vital facilities

  4. Realistic full wave modeling of focal plane array pixels.

    Energy Technology Data Exchange (ETDEWEB)

    Campione, Salvatore [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States). Electromagnetic Theory Dept.; Warne, Larry K. [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States). Electromagnetic Theory Dept.; Jorgenson, Roy E. [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States). Electromagnetic Theory Dept.; Davids, Paul [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States). Applied Photonic Microsystems Dept.; Peters, David W. [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States). Applied Photonic Microsystems Dept.

    2017-11-01

    Here, we investigate full-wave simulations of realistic implementations of multifunctional nanoantenna enabled detectors (NEDs). We focus on a 2x2 pixelated array structure that supports two wavelengths of operation. We design each resonating structure independently using full-wave simulations with periodic boundary conditions mimicking the whole infinite array. We then construct a supercell made of a 2x2 pixelated array with periodic boundary conditions mimicking the full NED; in this case, however, each pixel comprises 10-20 antennas per side. In this way, the cross-talk between contiguous pixels is accounted for in our simulations. We observe that, even though there are finite extent effects, the pixels work as designed, each responding at the respective wavelength of operation. This allows us to stress that realistic simulations of multifunctional NEDs need to be performed to verify the design functionality by taking into account finite extent and cross-talk effects.

  5. Aberrant hepatic artery

    International Nuclear Information System (INIS)

    Konstam, M.A.; Novelline, R.A.; Athanasoulis, C.A.

    1979-01-01

    In a patient undergoing selective hepatic arteriography for suspected liver trauma, a nonopacified area of the liver, initially thought to represent a hepatic hematoma, was later discovered to be due to the presence of an accessory right hepatic artery arising from the superior mesenteric artery. This case illustrates the need for a search for aberrant vasculature whenever a liver hematoma is suspected on the basis of a selective hepatic arteriogram. (orig.) [de

  6. Relationship between the arterial calcification detected in mammography and coronary artery disease

    Energy Technology Data Exchange (ETDEWEB)

    Topal, Ugur [Department of Radiology, Uludag University, Medical School, Goeruekle Campus, 16059 Bursa (Turkey)], E-mail: utopal@uludag.edu.tr; Kaderli, Aysel [Department of Cardiology, Uludag University, Medical School, Goeruekle Campus, 16059 Bursa (Turkey); Topal, Naile Bolca [Department of Radiology, Uludag University, Medical School, Goeruekle Campus, 16059 Bursa (Turkey); Ozdemir, Buelent; Yesilbursa, Dilek; Cordan, Jale [Department of Cardiology, Uludag University, Medical School, Goeruekle Campus, 16059 Bursa (Turkey); Ediz, Buelent [Department of Statistics, Uludag University, Medical School, Goeruekle Campus, 16059 Bursa (Turkey); Aydinlar, Ali [Department of Cardiology, Uludag University, Medical School, Goeruekle Campus, 16059 Bursa (Turkey)

    2007-09-15

    Objective: Arterial calcification is frequently encountered in mammography. The frequency of breast arterial calcification (BAC) increases with increasing age. Studies have shown that BAC is seen more frequently among the people who are under the risk of coronary artery diseases (CAD) such as diabetes and hypertension. The objective of this study is to investigate the relationship between the arterial calcification detected in mammography and the CAD. Material and methods: Screening mammography was performed in 123 women above the age of 40 years who had been examined with coronary angiography for the evaluation of CAD. The presence of BAC, number of affected vessels, and the distribution of calcification in the vessel wall were evaluated in the mammography. Subjects were questioned in terms of the cardiovasculary risk factors. The severity of CAD was evaluated according to the Gensini scoring. In addition, the number of blood vessels with stenosis of more than 50% was used as the vascular score. The correlation between Gensini and the vascular scores, and BAC was statistically evaluated using Mann-Whitney U and Kruskal-Wallis tests. Results: Eighty (65%) of 123 patients had CAD. BAC was detected in the mammography of 49 (39.8%) subjects. The ages and duration of menopause of the cases with BAC were significantly higher than those without BAC (p < 0.001). There was an almost significant correlation between the BAC and Gensini scores (p = 0.059). There was a significant increase in the frequency of BAC among subjects with more than two vessels with stenosis (p = 0.033). Conclusion: Frequency of BAC increases with increasing age. BAC is also frequently seen in subjects having severe coronary artery disease. Although increasing age may be a factor increasing the frequency of BAC, BAC may also be an indicator of CAD. Therefore, the mentioning of arterial calcification in mammography reports may be important in warning the clinician in terms of CAD.

  7. Blend Shape Interpolation and FACS for Realistic Avatar

    Science.gov (United States)

    Alkawaz, Mohammed Hazim; Mohamad, Dzulkifli; Basori, Ahmad Hoirul; Saba, Tanzila

    2015-03-01

    The quest of developing realistic facial animation is ever-growing. The emergence of sophisticated algorithms, new graphical user interfaces, laser scans and advanced 3D tools imparted further impetus towards the rapid advancement of complex virtual human facial model. Face-to-face communication being the most natural way of human interaction, the facial animation systems became more attractive in the information technology era for sundry applications. The production of computer-animated movies using synthetic actors are still challenging issues. Proposed facial expression carries the signature of happiness, sadness, angry or cheerful, etc. The mood of a particular person in the midst of a large group can immediately be identified via very subtle changes in facial expressions. Facial expressions being very complex as well as important nonverbal communication channel are tricky to synthesize realistically using computer graphics. Computer synthesis of practical facial expressions must deal with the geometric representation of the human face and the control of the facial animation. We developed a new approach by integrating blend shape interpolation (BSI) and facial action coding system (FACS) to create a realistic and expressive computer facial animation design. The BSI is used to generate the natural face while the FACS is employed to reflect the exact facial muscle movements for four basic natural emotional expressions such as angry, happy, sad and fear with high fidelity. The results in perceiving the realistic facial expression for virtual human emotions based on facial skin color and texture may contribute towards the development of virtual reality and game environment of computer aided graphics animation systems.

  8. Fully Realistic Multi-Criteria Multi-Modal Routing

    OpenAIRE

    Gündling, Felix; Keyhani, Mohammad Hossein; Schnee, Mathias; Weihe, Karsten

    2014-01-01

    We report on a multi-criteria search system, in which the German long- and short-distance trains, local public transport, walking, private car, private bike, and taxi are incorporated. The system is fully realistic. Three optimization criteria are addressed: travel time, travel cost, and convenience. Our algorithmic approach computes a complete Pareto set of reasonable connections. The computational study demonstrates that, even in such a large-scale, highly complex scenario, approp...

  9. Realistically Rendering SoC Traffic Patterns with Interrupt Awareness

    DEFF Research Database (Denmark)

    Angiolini, Frederico; Mahadevan, Sharkar; Madsen, Jan

    2005-01-01

    to generate realistic test traffic. This paper presents a selection of applications using interrupt-based synchronization; a reference methodology to split such applications in execution subflows and to adjust the overall execution stream based upon hardware events; a reactive simulation device capable...... of correctly replicating such software behaviours in the MPSoC design phase. Additionally, we validate the proposed concept by showing cycle-accurate reproduction of a previously traced application flow....

  10. Realistic modeling of chamber transport for heavy-ion fusion

    International Nuclear Information System (INIS)

    Sharp, W.M.; Grote, D.P.; Callahan, D.A.; Tabak, M.; Henestroza, E.; Yu, S.S.; Peterson, P.F.; Welch, D.R.; Rose, D.V.

    2003-01-01

    Transport of intense heavy-ion beams to an inertial-fusion target after final focus is simulated here using a realistic computer model. It is found that passing the beam through a rarefied plasma layer before it enters the fusion chamber can largely neutralize the beam space charge and lead to a usable focal spot for a range of ion species and input conditions

  11. A scan for models with realistic fermion mass patterns

    International Nuclear Information System (INIS)

    Bijnens, J.; Wetterich, C.

    1986-03-01

    We consider models which have no small Yukawa couplings unrelated to symmetry. This situation is generic in higher dimensional unification where Yukawa couplings are predicted to have strength similar to the gauge couplings. Generations have then to be differentiated by symmetry properties and the structure of fermion mass matrices is given in terms of quantum numbers alone. We scan possible symmetries leading to realistic mass matrices. (orig.)

  12. Bell Operator Method to Classify Local Realistic Theories

    International Nuclear Information System (INIS)

    Nagata, Koji

    2010-01-01

    We review the historical fact of multipartite Bell inequalities with an arbitrary number of settings. An explicit local realistic model for the values of a correlation function, given in a two-setting Bell experiment (two-setting model), works only for the specific set of settings in the given experiment, but cannot construct a local realistic model for the values of a correlation function, given in a continuous-infinite settings Bell experiment (infinite-setting model), even though there exist two-setting models for all directions in space. Hence, the two-setting model does not have the property that the infinite-setting model has. Here, we show that an explicit two-setting model cannot construct a local realistic model for the values of a correlation function, given in an M-setting Bell experiment (M-setting model), even though there exist two-setting models for the M measurement directions chosen in the given M-setting experiment. Hence, the two-setting model does not have the property that the M-setting model has. (general)

  13. I-Love relations for incompressible stars and realistic stars

    Science.gov (United States)

    Chan, T. K.; Chan, AtMa P. O.; Leung, P. T.

    2015-02-01

    In spite of the diversity in the equations of state of nuclear matter, the recently discovered I-Love-Q relations [Yagi and Yunes, Science 341, 365 (2013), 10.1126/science.1236462], which relate the moment of inertia, tidal Love number (deformability), and the spin-induced quadrupole moment of compact stars, hold for various kinds of realistic neutron stars and quark stars. While the physical origin of such universality is still a current issue, the observation that the I-Love-Q relations of incompressible stars can well approximate those of realistic compact stars hints at a new direction to approach the problem. In this paper, by establishing recursive post-Minkowskian expansion for the moment of inertia and the tidal deformability of incompressible stars, we analytically derive the I-Love relation for incompressible stars and show that the so-obtained formula can be used to accurately predict the behavior of realistic compact stars from the Newtonian limit to the maximum mass limit.

  14. Realistic terrain visualization based on 3D virtual world technology

    Science.gov (United States)

    Huang, Fengru; Lin, Hui; Chen, Bin; Xiao, Cai

    2010-11-01

    The rapid advances in information technologies, e.g., network, graphics processing, and virtual world, have provided challenges and opportunities for new capabilities in information systems, Internet applications, and virtual geographic environments, especially geographic visualization and collaboration. In order to achieve meaningful geographic capabilities, we need to explore and understand how these technologies can be used to construct virtual geographic environments to help to engage geographic research. The generation of three-dimensional (3D) terrain plays an important part in geographical visualization, computer simulation, and virtual geographic environment applications. The paper introduces concepts and technologies of virtual worlds and virtual geographic environments, explores integration of realistic terrain and other geographic objects and phenomena of natural geographic environment based on SL/OpenSim virtual world technologies. Realistic 3D terrain visualization is a foundation of construction of a mirror world or a sand box model of the earth landscape and geographic environment. The capabilities of interaction and collaboration on geographic information are discussed as well. Further virtual geographic applications can be developed based on the foundation work of realistic terrain visualization in virtual environments.

  15. ARTERIAL REVASCULARIZATION WITH THE RIGHT GASTROEPIPLOIC ARTERY AND INTERNAL MAMMARY ARTERIES IN 300 PATIENTS

    NARCIS (Netherlands)

    GRANDJEAN, JG; BOONSTRA, PW; DENHEYER, P; EBELS, T; KIRKLIN, JW

    From September 1989 to September 1992, the right gastroepiploic artery in combination with one or both internal mammary arteries was used as a graft in 300 patients who underwent coronary artery bypass grafting. The gastroepiploic artery was the primary choice in preference to the saphenous vein.

  16. Pengembangan Lembar Kerja Siswa (LKS) Berbasis Pendekatan Realistic Mathematic Education (RME) untuk Memfasilitasi Kemampuan Representasi Matematis Siswa SMP

    OpenAIRE

    Ranti Mustika Sari; Zubaidah Amir M. Z.; Risnawati Risnawati

    2017-01-01

    This research aimed at developing, producing a valid and practical students' workbook Realistic Mathematic Education Approach Based and facilitating student mathematic representing ability on Systems of Linear Equations in Two Variables material.The method of this research was a Research and Development (R&D) through the development of 4-D (Define, Design, Develop, and Disseminate) Model.This research was administered at State Junior High School 2 Pasir Penyu.The subjects of this research...

  17. Doppler examination of the periorbital arteries adds valuable hemodynamic information in carotid artery disease

    DEFF Research Database (Denmark)

    Sillesen, H; Schroeder, T; Steenberg, H J

    1987-01-01

    The periorbital flow direction and internal carotid artery (ICA) angiogram were compared to the ICA pressure gradient across the stenosis and the distal ICA pressure in 51 patients subjected to carotid endarterectomy. All 17 patients with inverted periorbital flow had stenoses exceeding 50%. The ...... collaterals and, Patients with 50% stenosis or more and insufficient collaterals....

  18. Elevated oxidative stress among coronary artery disease patients on statin therapy: A cross sectional study

    Directory of Open Access Journals (Sweden)

    Sabitha Palazhy

    2015-05-01

    Conclusions: Though coronary artery disease subjects had healthy lipid profile, oxidative stress, a recognized risk factor for coronary events, was still elevated among this patient group. Novel risk factors were not found to be major predictors for coronary artery disease among the study subjects.

  19. Embolization of a large, symptomatic splenic artery pseudoaneurysm

    International Nuclear Information System (INIS)

    Kukliński, Adam; Batycki, Krzysztof; Matuszewski, Wiesław; Ostrach, Andrzej; Kupis, Zbigniew; Łęgowik, Tomasz

    2014-01-01

    Splenic artery aneurysm is the third most common abdominal aneurysm. Most often it is due to pancreatitis. There were only 19 cases of aneurysms larger than 5 cm in diameter described in the literature. Management of splenic artery aneurysms depends on the size and symptoms. Invasive treatment modalities involve open procedures and interventional radiology methods (endovascular). A 44-years-old male with chronic pancreatitis, in a gradually worsening general condition due to a large splenic artery aneurysm, was subjected to the procedure. Blood flow through the aneurysm was cut-off by implanting a covered stent between celiac trunk and common hepatic artery. Patient’s general condition rapidly improved, allowing discharge home in good state soon after the procedure. Percutaneous embolization appears to be the best method of treatment of large splenic artery aneurysms. Complications of such treatment are significantly less dangerous than those associated with surgery

  20. Impairment of Arterial Compliance in Cushing’s Syndrome

    Science.gov (United States)

    Maria Zedda, Angela; Mercuro, Giuseppe

    2014-01-01

    Abstract Arterial stiffness may be useful for stratifying cardiovascular risk in individuals suffering from a number of pathologies, such as hypertension, diabetes, obesity, dyslipidaemia and coronary artery disease. Cushing’s syndrome is underpinned by a complex metabolic syndrome, which is potentially implicated in the onset of blood vessel alterations and the increase in arterial wall stiffness. The aim of this paper was to perform a review about the most important studies conducted in order to evaluate the arterial distensibility profile of subjects affected by Cushing’s syndrome. Increased arterial stiffness may persist even after successful cure of this disease. It is therefore of fundamental importance to identify the presence of early vascular alterations in these patients, in order to commence their treatment and thus attempt to prevent the subsequent onset of adverse cardiovascular events.

  1. Peripheral arterial angiography and interventional treatment in diabetic foot ulcers

    International Nuclear Information System (INIS)

    Guo Xiaohua; Cheng Yongde; Hu Suying; He Jianrong; Lin Kaiqin; Jin Honglai; Shi Shijie

    2003-01-01

    Objective: To assess the changes of peripheral arteries and choice of interventional treatment in diabetic foot ulcers. Methods: Thirty-six diabetic patients with foot ulcers were examined by lower extremity DSA with simultaneous ultrasonic Doppler examination for correlative study and interventional treatment carried out in 17 segmental stenotic cases. Among them, 12 patients were treated by PTA and 5 patients by intravascular stenting. Results: Irregular stenoses and obstruction were observed in all patients with peripheral foot ulcers. DSA examination was more reliable comparing with Doppler examination for demonstration of the arterial injury above the level of popliteal artery. PTA and primary stenting were effective in all of these subjects outcoming with promotion of the lower extremity arterial blood perfusion and foreseen curing efficacy. Conclusions: Peripheral arterial stenoses were common in diabetic patients with foot ulcers. In clinical practice, DSA examination and interventional treatment could give a fertile prognosis and reduce disabling

  2. Effects of realistic force feedback in a robotic assisted minimally invasive surgery system.

    Science.gov (United States)

    Moradi Dalvand, Mohsen; Shirinzadeh, Bijan; Nahavandi, Saeid; Smith, Julian

    2014-06-01

    Robotic assisted minimally invasive surgery systems not only have the advantages of traditional laparoscopic procedures but also restore the surgeon's hand-eye coordination and improve the surgeon's precision by filtering hand tremors. Unfortunately, these benefits have come at the expense of the surgeon's ability to feel. Several research efforts have already attempted to restore this feature and study the effects of force feedback in robotic systems. The proposed methods and studies have some shortcomings. The main focus of this research is to overcome some of these limitations and to study the effects of force feedback in palpation in a more realistic fashion. A parallel robot assisted minimally invasive surgery system (PRAMiSS) with force feedback capabilities was employed to study the effects of realistic force feedback in palpation of artificial tissue samples. PRAMiSS is capable of actually measuring the tip/tissue interaction forces directly from the surgery site. Four sets of experiments using only vision feedback, only force feedback, simultaneous force and vision feedback and direct manipulation were conducted to evaluate the role of sensory feedback from sideways tip/tissue interaction forces with a scale factor of 100% in characterising tissues of varying stiffness. Twenty human subjects were involved in the experiments for at least 1440 trials. Friedman and Wilcoxon signed-rank tests were employed to statistically analyse the experimental results. Providing realistic force feedback in robotic assisted surgery systems improves the quality of tissue characterization procedures. Force feedback capability also increases the certainty of characterizing soft tissues compared with direct palpation using the lateral sides of index fingers. The force feedback capability can improve the quality of palpation and characterization of soft tissues of varying stiffness by restoring sense of touch in robotic assisted minimally invasive surgery operations.

  3. Mechanical design in arteries.

    Science.gov (United States)

    Shadwick, R E

    1999-12-01

    The most important mechanical property of the artery wall is its non-linear elasticity. Over the last century, this has been well-documented in vessels in many animals, from humans to lobsters. Arteries must be distensible to provide capacitance and pulse-smoothing in the circulation, but they must also be stable to inflation over a range of pressure. These mechanical requirements are met by strain-dependent increases in the elastic modulus of the vascular wall, manifest by a J-shaped stress-strain curve, as typically exhibited by other soft biological tissues. All vertebrates and invertebrates with closed circulatory systems have arteries with this non-linear behaviour, but specific tissue properties vary to give correct function for the physiological pressure range of each species. In all cases, the non-linear elasticity is a product of the parallel arrangement of rubbery and stiff connective tissue elements in the artery wall, and differences in composition and tissue architecture can account for the observed variations in mechanical properties. This phenomenon is most pronounced in large whales, in which very high compliance in the aortic arch and exceptionally low compliance in the descending aorta occur, and is correlated with specific modifications in the arterial structure.

  4. Traumatic Distal Ulnar Artery Thrombosis

    Directory of Open Access Journals (Sweden)

    Ahmet A. Karaarslan

    2014-01-01

    Full Text Available This paper is about a posttraumatic distal ulnar artery thrombosis case that has occurred after a single blunt trauma. The ulnar artery thrombosis because of chronic trauma is a frequent condition (hypothenar hammer syndrome but an ulnar artery thrombosis because of a single direct blunt trauma is rare. Our patient who has been affected by a single blunt trauma to his hand and developed ulnar artery thrombosis has been treated by resection of the thrombosed ulnar artery segment. This report shows that a single blunt trauma can cause distal ulnar artery thrombosis in the hand and it can be treated merely by thrombosed segment resection in suitable cases.

  5. Gauge coupling unification in realistic free-fermionic string models

    International Nuclear Information System (INIS)

    Dienes, K.R.; Faraggi, A.E.

    1995-01-01

    We discuss the unification of gauge couplings within the framework of a wide class of realistic free-fermionic string models which have appeared in the literature, including the flipped SU(5), SO(6)xSO(4), and various SU(3)xSU(2)xU(1) models. If the matter spectrum below the string scale is that of the Minimal Supersymmetric Standard Model (MSSM), then string unification is in disagreement with experiment. We therefore examine several effects that may modify the minimal string predictions. First, we develop a systematic procedure for evaluating the one-loop heavy string threshold corrections in free-fermionic string models, and we explicitly evaluate these corrections for each of the realistic models. We find that these string threshold corrections are small, and we provide general arguments explaining why such threshold corrections are suppressed in string theory. Thus heavy thresholds cannot resolve the disagreement with experiment. We also study the effect of non-standard hypercharge normalizations, light SUSY thresholds, and intermediate-scale gauge structure, and similarly conclude that these effects cannot resolve the disagreement with low-energy data. Finally, we examine the effects of additional color triplets and electroweak doublets beyond the MSSM. Although not required in ordinary grand unification scenarios, such states generically appear within the context of certain realistic free-fermionic string models. We show that if these states exist at the appropriate thresholds, then the gauge couplings will indeed unify at the string scale. Thus, within these string models, string unification can be in agreement with low-energy data. (orig.)

  6. MetAssimulo:Simulation of Realistic NMR Metabolic Profiles

    Directory of Open Access Journals (Sweden)

    De Iorio Maria

    2010-10-01

    Full Text Available Abstract Background Probing the complex fusion of genetic and environmental interactions, metabolic profiling (or metabolomics/metabonomics, the study of small molecules involved in metabolic reactions, is a rapidly expanding 'omics' field. A major technique for capturing metabolite data is 1H-NMR spectroscopy and this yields highly complex profiles that require sophisticated statistical analysis methods. However, experimental data is difficult to control and expensive to obtain. Thus data simulation is a productive route to aid algorithm development. Results MetAssimulo is a MATLAB-based package that has been developed to simulate 1H-NMR spectra of complex mixtures such as metabolic profiles. Drawing data from a metabolite standard spectral database in conjunction with concentration information input by the user or constructed automatically from the Human Metabolome Database, MetAssimulo is able to create realistic metabolic profiles containing large numbers of metabolites with a range of user-defined properties. Current features include the simulation of two groups ('case' and 'control' specified by means and standard deviations of concentrations for each metabolite. The software enables addition of spectral noise with a realistic autocorrelation structure at user controllable levels. A crucial feature of the algorithm is its ability to simulate both intra- and inter-metabolite correlations, the analysis of which is fundamental to many techniques in the field. Further, MetAssimulo is able to simulate shifts in NMR peak positions that result from matrix effects such as pH differences which are often observed in metabolic NMR spectra and pose serious challenges for statistical algorithms. Conclusions No other software is currently able to simulate NMR metabolic profiles with such complexity and flexibility. This paper describes the algorithm behind MetAssimulo and demonstrates how it can be used to simulate realistic NMR metabolic profiles with

  7. Ultra-Reliable Communications in Failure-Prone Realistic Networks

    DEFF Research Database (Denmark)

    Gerardino, Guillermo Andrés Pocovi; Lauridsen, Mads; Alvarez, Beatriz Soret

    2016-01-01

    We investigate the potential of different diversity and interference management techniques to achieve the required downlink SINR outage probability for ultra-reliable communications. The evaluation is performed in a realistic network deployment based on site-specific data from a European capital....... Micro and macroscopic diversity techniques are proved to be important enablers of ultra-reliable communications. Particularly, it is shown how a 4x4 MIMO scheme with three orders of macroscopic diversity can achieve the required SINR outage performance. Smaller gains are obtained from interference...

  8. Capturing and reproducing realistic acoustic scenes for hearing research

    DEFF Research Database (Denmark)

    Marschall, Marton; Buchholz, Jörg

    Accurate spatial audio recordings are important for a range of applications, from the creation of realistic virtual sound environments to the evaluation of communication devices, such as hearing instruments and mobile phones. Spherical microphone arrays are particularly well-suited for capturing....... The properties of MOA microphone layouts and processing were investigated further by considering several order combinations. It was shown that the performance for horizontal vs. elevated sources can be adjusted by varying the order combination, but that a benefit of the higher horizontal orders can only be seen...

  9. Scaling up complex interventions: insights from a realist synthesis.

    Science.gov (United States)

    Willis, Cameron D; Riley, Barbara L; Stockton, Lisa; Abramowicz, Aneta; Zummach, Dana; Wong, Geoff; Robinson, Kerry L; Best, Allan

    2016-12-19

    Preventing chronic diseases, such as cancer, cardiovascular disease and diabetes, requires complex interventions, involving multi-component and multi-level efforts that are tailored to the contexts in which they are delivered. Despite an increasing number of complex interventions in public health, many fail to be 'scaled up'. This study aimed to increase understanding of how and under what conditions complex public health interventions may be scaled up to benefit more people and populations.A realist synthesis was conducted and discussed at an in-person workshop involving practitioners responsible for scaling up activities. Realist approaches view causality through the linkages between changes in contexts (C) that activate mechanisms (M), leading to specific outcomes (O) (CMO configurations). To focus this review, three cases of complex interventions that had been successfully scaled up were included: Vibrant Communities, Youth Build USA and Pathways to Education. A search strategy of published and grey literature related to each case was developed, involving searches of relevant databases and nominations from experts. Data extracted from included documents were classified according to CMO configurations within strategic themes. Findings were compared and contrasted with guidance from diffusion theory, and interpreted with knowledge users to identify practical implications and potential directions for future research.Four core mechanisms were identified, namely awareness, commitment, confidence and trust. These mechanisms were activated within two broad scaling up strategies, those of renewing and regenerating, and documenting success. Within each strategy, specific actions to change contexts included building partnerships, conducting evaluations, engaging political support and adapting funding models. These modified contexts triggered the identified mechanisms, leading to a range of scaling up outcomes, such as commitment of new communities, changes in relevant

  10. Dynamic apeerture in damping rings with realistic wigglers

    Energy Technology Data Exchange (ETDEWEB)

    Cai, Yunhai; /SLAC

    2005-05-04

    The International Linear Collider based on superconducting RF cavities requires the damping rings to have extremely small equilibrium emittance, huge circumference, fast damping time, and large acceptance. To achieve all of these requirements is a very challenging task. In this paper, we will present a systematic approach to designing the damping rings using simple cells and non-interlaced sextupoles. The designs of the damping rings with various circumferences and shapes, including dogbone, are presented. To model realistic wigglers, we have developed a new hybrid symplectic integrator for faster and accurate evaluation of dynamic aperture of the lattices.

  11. Dynamic Enhanced Inter-Cell Interference Coordination for Realistic Networks

    DEFF Research Database (Denmark)

    Pedersen, Klaus I.; Alvarez, Beatriz Soret; Barcos, Sonia

    2016-01-01

    Enhanced Inter-Cell Interference Coordination (eICIC) is a key ingredient to boost the performance of co-channel Heterogeneous Networks (HetNets). eICIC encompasses two main techniques: Almost Blank Subframes (ABS), during which the macro cell remains silent to reduce the interference, and biased...... and an opportunistic approach exploiting the varying cell conditions. Moreover, an autonomous fast distributed muting algorithm is presented, which is simple, robust, and well suited for irregular network deployments. Performance results for realistic network deployments show that the traditional semi-static e...

  12. Realistic shell-model calculations for Sn isotopes

    International Nuclear Information System (INIS)

    Covello, A.; Andreozzi, F.; Coraggio, L.; Gargano, A.; Porrino, A.

    1997-01-01

    We report on a shell-model study of the Sn isotopes in which a realistic effective interaction derived from the Paris free nucleon-nucleon potential is employed. The calculations are performed within the framework of the seniority scheme by making use of the chain-calculation method. This provides practically exact solutions while cutting down the amount of computational work required by a standard seniority-truncated calculation. The behavior of the energy of several low-lying states in the isotopes with A ranging from 122 to 130 is presented and compared with the experimental one. (orig.)

  13. Turbulence studies in tokamak boundary plasmas with realistic divertor geometry

    International Nuclear Information System (INIS)

    Xu, X.Q.; Cohen, R.H.; Porter, G.D.; Rognlien, T.; Ryutov, D.D.; Myra, J.R.; D'Ippolito, D.A.; Moyer, R.; Groebner, R.J.

    2001-01-01

    Results are presented from the 3D nonlocal electromagnetic turbulence code BOUT and the linearized shooting code BAL for studies of turbulence in tokamak boundary plasmas and its relationship to the L-H transition, in a realistic divertor plasma geometry. The key results include: (1) the identification of the dominant resistive X-point mode in divertor geometry and (2) turbulence suppression in the L-H transition by shear in the ExB drift speed, ion diamagnetism and nite polarization. Based on the simulation results, a parameterization of the transport is given that includes the dependence on the relevant physical parameters. (author)

  14. Turbulence studies in tokamak boundary plasmas with realistic divertor geometry

    International Nuclear Information System (INIS)

    Xu, X.Q.; Cohen, R.H.; Por, G.D. ter; Rognlien, T.D.; Ryutov, D.D.; Myra, J.R.; D'Ippolito, D.A.; Moyer, R.; Groebner, R.J.

    1999-01-01

    Results are presented from the 3D nonlocal electromagnetic turbulence code BOUT and the linearized shooting code BAL for studies of turbulence in tokamak boundary plasmas and its relationship to the L-H transition, in a realistic divertor plasma geometry. The key results include: (1) the identification of the dominant resistive X-point mode in divertor geometry and (2) turbulence suppression in the L-H transition by shear in the E x B drift speed, ion diamagnetism and finite polarization. Based on the simulation results, a parameterization of the transport is given that includes the dependence on the relevant physical parameters. (author)

  15. On Small Antenna Measurements in a Realistic MIMO Scenario

    DEFF Research Database (Denmark)

    Yanakiev, Boyan; Nielsen, Jesper Ødum; Pedersen, Gert Frølund

    2010-01-01

    . The problem using coaxial cable is explained and a solution suitable for long distance channel sounding is presented. A large scale measurement campaign is then described. Special attention is paid to bring the measurement setup as close as possible to a realistic LTE network of the future, with attention......This paper deals with the challenges related to evaluating the performance of multiple, small terminal antennas within a natural MIMO environment. The focus is on the antenna measurement accuracy. First a method is presented for measuring small phone mock-ups, with the use of optical fibers...

  16. A continuous family of realistic SUSY SU(5) GUTs

    Energy Technology Data Exchange (ETDEWEB)

    Bajc, Borut, E-mail: borut.bajc@ijs.si [J. Stefan Institute, Jamova cesta 39, 1000, Ljubljana (Slovenia)

    2016-06-21

    It is shown that the minimal renormalizable supersymmetric SU(5) is still realistic providing the supersymmetric scale is at least few tens of TeV or large R-parity violating terms are considered. In the first case the vacuum is metastable, and different consistency constraints can give a bounded allowed region in the tan β − m{sub susy} plane. In the second case the mass eigenstate electron (down quark) is a linear combination of the original electron (down quark) and Higgsino (heavy colour triplet), and the mass ratio of bino and wino is determined. Both limits lead to light gravitino dark matter.

  17. Do Preschoolers Recognize The Emotional Expressiveness of Colors in Realistic and Abstract Art Paintings?

    Science.gov (United States)

    Pouliou, Dimitra; Bonoti, Fotini; Nikonanou, Niki

    2018-01-01

    The present study was designed to examine preschoolers' ability to recognize the emotional expressiveness of an art painting, through its colors. To attain this aim 78 children, 3-5 years old were presented with realistic and abstract paintings conveying either happiness or sadness and were asked to choose those which matched the appropriate emotion. In total 16 paintings were used, which varied in color, while their subject matter was held as constant as possible after they had been previously rated by a group of adults to ensure that they conveyed the two emotions under investigation. Results showed that children's ability to recognize the emotional expressiveness of a painting through its colors appears at 3 years old and increases significantly at 4 and 5 years old. It was also found that the mood of happiness was more easily recognized than that of sadness, while the style of art paintings (realistic vs. abstract) did not affect children's ability to recognize emotions.

  18. Endovascular uterine artery interventions

    Directory of Open Access Journals (Sweden)

    Chandan J Das

    2017-01-01

    Full Text Available Percutaneous vascular embolization plays an important role in the management of various gynecologic and obstetric abnormalities. Transcatheter embolization is a minimally invasive alternative procedure to surgery with reduced morbidity and mortality, and preserves the patient's future fertility potential. The clinical indications for transcatheter embolization are much broader and include many benign gynecologic conditions, such as fibroid, adenomyosis, and arteriovenous malformations (AVMs, as well as intractable bleeding due to inoperable advanced-stage malignancies. The most well-known and well-studied indication is uterine fibroid embolization. Uterine artery embolization (UAE may be performed to prevent or treat bleeding associated with various obstetric conditions, including postpartum hemorrhage (PPH, placental implantation abnormality, and ectopic pregnancy. Embolization of the uterine artery or the internal iliac artery also may be performed to control pelvic bleeding due to coagulopathy or iatrogenic injury. This article discusses these gynecologic and obstetric indications for transcatheter embolization and reviews procedural techniques and outcomes.

  19. Cervicocephalic arterial dissection

    International Nuclear Information System (INIS)

    Suyama, Kazuhiko; Hayashi, Kentaro; Nagata, Izumi

    2008-01-01

    The authors review the clinical and neuroradiological features of cervicocephalic arterial dissection, which is occasionally seen in young adults, with special reference to the differences in the region of occurrence of these lesions between patients in Western countries and Japan. In Western countries, the cervical internal carotid artery is the most common site of occurrence of these lesions; however, in Japan, these lesions have been frequently reported to occure in the intracranial vertebral artery. Most clinical manifestations of cervical arterial dissection are non-hemorrhagic events such as headaches associated with arterial dissection or cerebral ischemia caused by a distal embolism following thrombus formation in the cervical lesion. On the other hand, a subarachnoid hemorrhage and cerebral infarction are frequently observed in intracranial arterial dissections. Non-invasive procedures, including MR imaging, are useful for demonstrating characteristic features of this condition such as the presence of an intimal flap or a double lumen, and for monitoring the chronological changes in the lesions, which may regress spontaneously. Since the pathological mechanisms underlying the progression and/or the regression of this condition are still unknown, the clinical evidence indicating the optimal therapeutic strategies has not yet been reported. Nevertheless, conservative therapy, including antithrombotic treatment, is widely used for the treatment of non-hemorrhagic lesions, which generally results in good clinical outcomes. Further, surgical intervention is essential for the treatment of lesions with a subarachnoid hemorrhage to prevent fatal rebleeding, and it is also required for the treatment of certain non-hemorrhagic lesions. Recent advancements in surgical procedures, especially endovascular treatments, may therefore be helpful in the management of similar complicated vascular conditions. (author)

  20. [Vascular calcifications in subjects with and without chronic renal failure: types, sites and risk factors].

    Science.gov (United States)

    Marinelli, Annibale; Di Napoli, Anteo

    2017-04-01

    Vascular calcifications worse outcomes in the general population and in patients on dialysis. We investigated 146 patients on chronic hemodialysis and 63 healthy controls with normal renal function under 65 years of age. All subjects underwent B-mode ultrasonography of common and internal carotid artery, abdominal aorta, common and superficial femoral artery and posterior tibial artery to assess the presence of intimal and medial calcifications. Intimal and media calcifications were present at the level of the carotid vessel, the abdominal aorta, the common femoral artery, the superficial femoral artery and the posterior tibial artery, respectively in 45%, 50%, 45%, 50%, 42% of patients on dialysis and in 5%, 15%, 24%, 5%, 2% of controls (p chronic hemodialysis. Ultrasonography currently available in Nephrology, is a sensitive, reproducible, inexpensive imaging technique to identify arterial intimal and medial calcification in high-risk cardiovascular subjects. Copyright by Società Italiana di Nefrologia SIN, Rome, Italy.

  1. Arterial disease after radiotherapy

    International Nuclear Information System (INIS)

    Bigot, J.M.; Mathieu, D.; Reizine, D.

    1983-01-01

    Disease of the large arterial vessels is a relatively unknown complication of radiotherapy. However, it should be considered in the same manner as the other complications of irradiation when a tumour recurrence is suspected. The experimental studies of Kirkpatrick and Konings, demonstrating the synergy between irradiation and hypercholesterolemia in the precocity and gravity of vascular complications are recalled. The different localisations reported in the litterature are discussed: coronary, pulmonary, thoracic aorta, supra aortic, renal, digestive and ilio-femoral arteries. Finally, the difficulty of diagnosis of post-radiotherapy without clinical, radiological or anatomopathological confirmation, is underlined [fr

  2. Renal artery stenosis.

    Science.gov (United States)

    Tafur-Soto, Jose David; White, Christopher J

    2015-02-01

    Atherosclerotic renal artery stenosis (RAS) is the single largest cause of secondary hypertension; it is associated with progressive renal insufficiency and causes cardiovascular complications such as refractory heart failure and flash pulmonary edema. Medical therapy, including risk factor modification, renin-angiotensin-aldosterone system antagonists, lipid-lowering agents, and antiplatelet therapy, is advised in all patients. Patients with uncontrolled renovascular hypertension despite optimal medical therapy, ischemic nephropathy, and cardiac destabilization syndromes who have severe RAS are likely to benefit from renal artery revascularization. Screening for RAS can be done with Doppler ultrasonography, CT angiography, and magnetic resonance angiography. Copyright © 2015 Elsevier Inc. All rights reserved.

  3. Systemic Arterial-to-Pulmonary Artery Shunt Utilization

    African Journals Online (AJOL)

    multiruka1

    In certain circumstances, such as cyanotic neonates with tetralogy of Fallot (4) or cyanotic patients with. Tetralogy of Fallot and hypoplastic pulmonary arteries. (5), better outcomes are obtained if definitive surgery. (total correction or palliation) is preceded by creation of a systemic arterial-to-pulmonary artery shunt (SAPAS).

  4. Abnormal pulmonary artery stiffness in pulmonary arterial hypertension: in vivo study with intravascular ultrasound.

    Directory of Open Access Journals (Sweden)

    Edmund M T Lau

    Full Text Available BACKGROUND: There is increasing recognition that pulmonary artery stiffness is an important determinant of right ventricular (RV afterload in pulmonary arterial hypertension (PAH. We used intravascular ultrasound (IVUS to evaluate the mechanical properties of the elastic pulmonary arteries (PA in subjects with PAH, and assessed the effects of PAH-specific therapy on indices of arterial stiffness. METHOD: Using IVUS and simultaneous right heart catheterisation, 20 pulmonary segments in 8 PAH subjects and 12 pulmonary segments in 8 controls were studied to determine their compliance, distensibility, elastic modulus and stiffness index β. PAH subjects underwent repeat IVUS examinations after 6-months of bosentan therapy. RESULTS: AT BASELINE, PAH SUBJECTS DEMONSTRATED GREATER STIFFNESS IN ALL MEASURED INDICES COMPARED TO CONTROLS: compliance (1.50±0.11×10(-2 mm(2/mmHg vs 4.49±0.43×10(-2 mm(2/mmHg, p<0.0001, distensibility (0.32±0.03%/mmHg vs 1.18±0.13%/mmHg, p<0.0001, elastic modulus (720±64 mmHg vs 198±19 mmHg, p<0.0001, and stiffness index β (15.0±1.4 vs 11.0±0.7, p = 0.046. Strong inverse exponential associations existed between mean pulmonary artery pressure and compliance (r(2 = 0.82, p<0.0001, and also between mean PAP and distensibility (r(2 = 0.79, p = 0.002. Bosentan therapy, for 6-months, was not associated with any significant changes in all indices of PA stiffness. CONCLUSION: Increased stiffness occurs in the proximal elastic PA in patients with PAH and contributes to the pathogenesis RV failure. Bosentan therapy may not be effective at improving PA stiffness.

  5. Development of realistic thermal hydraulic system analysis code

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Won Jae; Chung, B. D; Kim, K. D. [and others

    2002-05-01

    The realistic safety analysis system is essential for nuclear safety research, advanced reactor development, safety analysis in nuclear industry and 'in-house' plant design capability development. In this project, we have developed a best-estimate multi-dimensional thermal-hydraulic system code, MARS, which is based on the integrated version of the RELAP5 and COBRA-TF codes. To improve the realistic analysis capability, we have improved the models for multi-dimensional two-phase flow phenomena and for advanced two-phase flow modeling. In addition, the GUI (Graphic User Interface) feature were developed to enhance the user's convenience. To develop the coupled analysis capability, the MARS code were linked with the three-dimensional reactor kinetics code (MASTER), the core thermal analysis code (COBRA-III/CP), and the best-estimate containment analysis code (CONTEMPT), resulting in MARS/MASTER/COBRA/CONTEMPT. Currently, the MARS code system has been distributed to 18 domestic organizations, including research, industrial, regulatory organizations and universities. The MARS has been being widely used for the safety research of existing PWRs, advanced PWR, CANDU and research reactor, the pre-test analysis of TH experiments, and others.

  6. Development of realistic thermal hydraulic system analysis code

    International Nuclear Information System (INIS)

    Lee, Won Jae; Chung, B. D; Kim, K. D.

    2002-05-01

    The realistic safety analysis system is essential for nuclear safety research, advanced reactor development, safety analysis in nuclear industry and 'in-house' plant design capability development. In this project, we have developed a best-estimate multi-dimensional thermal-hydraulic system code, MARS, which is based on the integrated version of the RELAP5 and COBRA-TF codes. To improve the realistic analysis capability, we have improved the models for multi-dimensional two-phase flow phenomena and for advanced two-phase flow modeling. In addition, the GUI (Graphic User Interface) feature were developed to enhance the user's convenience. To develop the coupled analysis capability, the MARS code were linked with the three-dimensional reactor kinetics code (MASTER), the core thermal analysis code (COBRA-III/CP), and the best-estimate containment analysis code (CONTEMPT), resulting in MARS/MASTER/COBRA/CONTEMPT. Currently, the MARS code system has been distributed to 18 domestic organizations, including research, industrial, regulatory organizations and universities. The MARS has been being widely used for the safety research of existing PWRs, advanced PWR, CANDU and research reactor, the pre-test analysis of TH experiments, and others

  7. Music therapy for palliative care: A realist review.

    Science.gov (United States)

    McConnell, Tracey; Porter, Sam

    2017-08-01

    Music therapy has experienced a rising demand as an adjunct therapy for symptom management among palliative care patients. We conducted a realist review of the literature to develop a greater understanding of how music therapy might benefit palliative care patients and the contextual mechanisms that promote or inhibit its successful implementation. We searched electronic databases (CINAHL, Embase, Medline, and PsychINFO) for literature containing information on music therapy for palliative care. In keeping with the realist approach, we examined all relevant literature to develop theories that could explain how music therapy works. A total of 51 articles were included in the review. Music therapy was found to have a therapeutic effect on the physical, psychological, emotional, and spiritual suffering of palliative care patients. We also identified program mechanisms that help explain music therapy's therapeutic effects, along with facilitating contexts for implementation. Music therapy may be an effective nonpharmacological approach to managing distressing symptoms in palliative care patients. The findings also suggest that group music therapy may be a cost-efficient and effective way to support staff caring for palliative care patients. We encourage others to continue developing the evidence base in order to expand our understanding of how music therapy works, with the aim of informing and improving the provision of music therapy for palliative care patients.

  8. Report of the workshop on realistic SSC lattices

    International Nuclear Information System (INIS)

    1985-10-01

    A workshop was held at the SSC Central Design Group from May 29 to June 4, 1985, on topics relating to the lattice of the SSC. The workshop marked a shift of emphasis from the investigation of simplified test lattices to the development of a realistic lattice suitable for the conceptual design report. The first day of the workshop was taken up by reviews of accelerator system requirements, of the reference design solutions for these requirements, of lattice work following the reference design, and of plans for the workshop. The work was divided among four working groups. The first, chaired by David Douglas, concerned the arcs of regular cells. The second group, which studied the utility insertions, was chaired by Beat Leemann. The third group, under David E. Johnson, concerned itself with the experimental insertions, dispersion suppressors, and phase trombones. The fourth group, responsible for global lattice considerations and the design of a new realistic lattice example, was led by Ernest Courant. The papers resulting from this workshop are roughly divided into three sets: those relating to specific lattice components, to complete lattices, and to other topics. Among the salient accomplishments of the workshop were additions to and optimization of lattice components, especially those relating to lattices using 1-in-1 magnets, either horizontally or vertically separated, and the design of complete lattice examples. Selected papers are indexed separately for inclusion in the Energy Science and Technology Database

  9. Realistic thermodynamic and statistical-mechanical measures for neural synchronization.

    Science.gov (United States)

    Kim, Sang-Yoon; Lim, Woochang

    2014-04-15

    Synchronized brain rhythms, associated with diverse cognitive functions, have been observed in electrical recordings of brain activity. Neural synchronization may be well described by using the population-averaged global potential VG in computational neuroscience. The time-averaged fluctuation of VG plays the role of a "thermodynamic" order parameter O used for describing the synchrony-asynchrony transition in neural systems. Population spike synchronization may be well visualized in the raster plot of neural spikes. The degree of neural synchronization seen in the raster plot is well measured in terms of a "statistical-mechanical" spike-based measure Ms introduced by considering the occupation and the pacing patterns of spikes. The global potential VG is also used to give a reference global cycle for the calculation of Ms. Hence, VG becomes an important collective quantity because it is associated with calculation of both O and Ms. However, it is practically difficult to directly get VG in real experiments. To overcome this difficulty, instead of VG, we employ the instantaneous population spike rate (IPSR) which can be obtained in experiments, and develop realistic thermodynamic and statistical-mechanical measures, based on IPSR, to make practical characterization of the neural synchronization in both computational and experimental neuroscience. Particularly, more accurate characterization of weak sparse spike synchronization can be achieved in terms of realistic statistical-mechanical IPSR-based measure, in comparison with the conventional measure based on VG. Copyright © 2014. Published by Elsevier B.V.

  10. Evaluating impact of clinical guidelines using a realist evaluation framework.

    Science.gov (United States)

    Reddy, Sandeep; Wakerman, John; Westhorp, Gill; Herring, Sally

    2015-12-01

    The Remote Primary Health Care Manuals (RPHCM) project team manages the development and publication of clinical protocols and procedures for primary care clinicians practicing in remote Australia. The Central Australian Rural Practitioners Association Standard Treatment Manual, the flagship manual of the RPHCM suite, has been evaluated for accessibility and acceptability in remote clinics three times in its 20-year history. These evaluations did not consider a theory-based framework or a programme theory, resulting in some limitations with the evaluation findings. With the RPHCM having an aim of enabling evidence-based practice in remote clinics and anecdotally reported to do so, testing this empirically for the full suite is vital for both stakeholders and future editions of the RPHCM. The project team utilized a realist evaluation framework to assess how, why and for what the RPHCM were being used by remote practitioners. A theory regarding the circumstances in which the manuals have and have not enabled evidence-based practice in the remote clinical context was tested. The project assessed this theory for all the manuals in the RPHCM suite, across government and aboriginal community-controlled clinics, in three regions of Australia. Implementing a realist evaluation framework to generate robust findings in this context has required innovation in the evaluation design and adaptation by researchers. This article captures the RPHCM team's experience in designing this evaluation. © 2015 John Wiley & Sons, Ltd.

  11. Ultra-realistic 3-D imaging based on colour holography

    International Nuclear Information System (INIS)

    Bjelkhagen, H I

    2013-01-01

    A review of recent progress in colour holography is provided with new applications. Colour holography recording techniques in silver-halide emulsions are discussed. Both analogue, mainly Denisyuk colour holograms, and digitally-printed colour holograms are described and their recent improvements. An alternative to silver-halide materials are the panchromatic photopolymer materials such as the DuPont and Bayer photopolymers which are covered. The light sources used to illuminate the recorded holograms are very important to obtain ultra-realistic 3-D images. In particular the new light sources based on RGB LEDs are described. They show improved image quality over today's commonly used halogen lights. Recent work in colour holography by holographers and companies in different countries around the world are included. To record and display ultra-realistic 3-D images with perfect colour rendering are highly dependent on the correct recording technique using the optimal recording laser wavelengths, the availability of improved panchromatic recording materials and combined with new display light sources.

  12. Electron percolation in realistic models of carbon nanotube networks

    International Nuclear Information System (INIS)

    Simoneau, Louis-Philippe; Villeneuve, Jérémie; Rochefort, Alain

    2015-01-01

    The influence of penetrable and curved carbon nanotubes (CNT) on the charge percolation in three-dimensional disordered CNT networks have been studied with Monte-Carlo simulations. By considering carbon nanotubes as solid objects but where the overlap between their electron cloud can be controlled, we observed that the structural characteristics of networks containing lower aspect ratio CNT are highly sensitive to the degree of penetration between crossed nanotubes. Following our efficient strategy to displace CNT to different positions to create more realistic statistical models, we conclude that the connectivity between objects increases with the hard-core/soft-shell radii ratio. In contrast, the presence of curved CNT in the random networks leads to an increasing percolation threshold and to a decreasing electrical conductivity at saturation. The waviness of CNT decreases the effective distance between the nanotube extremities, hence reducing their connectivity and degrading their electrical properties. We present the results of our simulation in terms of thickness of the CNT network from which simple structural parameters such as the volume fraction or the carbon nanotube density can be accurately evaluated with our more realistic models

  13. Spectroscopy of light nuclei with realistic NN interaction JISP

    International Nuclear Information System (INIS)

    Shirokov, A. M.; Vary, J. P.; Mazur, A. I.; Weber, T. A.

    2008-01-01

    Recent results of our systematic ab initio studies of the spectroscopy of s- and p-shell nuclei in fully microscopic large-scale (up to a few hundred million basis functions) no-core shell-model calculations are presented. A new high-quality realistic nonlocal NN interaction JISP is used. This interaction is obtained in the J-matrix inverse-scattering approach (JISP stands for the J-matrix inverse-scattering potential) and is of the form of a small-rank matrix in the oscillator basis in each of the NN partial waves, providing a very fast convergence in shell-model studies. The current purely two-body JISP model of the nucleon-nucleon interaction JISP16 provides not only an excellent description of two-nucleon data (deuteron properties and np scattering) with χ 2 /datum = 1.05 but also a better description of a wide range of observables (binding energies, spectra, rms radii, quadrupole moments, electromagnetic-transition probabilities, etc.) in all s-and p-shell nuclei than the best modern interaction models combining realistic nucleon-nucleon and three-nucleon interactions.

  14. Development of vortex model with realistic axial velocity distribution

    International Nuclear Information System (INIS)

    Ito, Kei; Ezure, Toshiki; Ohshima, Hiroyuki

    2014-01-01

    A vortex is considered as one of significant phenomena which may cause gas entrainment (GE) and/or vortex cavitation in sodium-cooled fast reactors. In our past studies, the vortex is assumed to be approximated by the well-known Burgers vortex model. However, the Burgers vortex model has a simple but unreal assumption that the axial velocity component is horizontally constant, while in real the free surface vortex has the axial velocity distribution which shows large gradient in radial direction near the vortex center. In this study, a new vortex model with realistic axial velocity distribution is proposed. This model is derived from the steady axisymmetric Navier-Stokes equation as well as the Burgers vortex model, but the realistic axial velocity distribution in radial direction is considered, which is defined to be zero at the vortex center and to approach asymptotically to zero at infinity. As the verification, the new vortex model is applied to the evaluation of a simple vortex experiment, and shows good agreements with the experimental data in terms of the circumferential velocity distribution and the free surface shape. In addition, it is confirmed that the Burgers vortex model fails to calculate accurate velocity distribution with the assumption of uniform axial velocity. However, the calculation accuracy of the Burgers vortex model can be enhanced close to that of the new vortex model in consideration of the effective axial velocity which is calculated as the average value only in the vicinity of the vortex center. (author)

  15. Neural Correlates of Realistic and Unrealistic Auditory Space Perception

    Directory of Open Access Journals (Sweden)

    Akiko Callan

    2011-10-01

    Full Text Available Binaural recordings can simulate externalized auditory space perception over headphones. However, if the orientation of the recorder's head and the orientation of the listener's head are incongruent, the simulated auditory space is not realistic. For example, if a person lying flat on a bed listens to an environmental sound that was recorded by microphones inserted in ears of a person who was in an upright position, the sound simulates an auditory space rotated 90 degrees to the real-world horizontal axis. Our question is whether brain activation patterns are different between the unrealistic auditory space (ie, the orientation of the listener's head and the orientation of the recorder's head are incongruent and the realistic auditory space (ie, the orientations are congruent. River sounds that were binaurally recorded either in a supine position or in an upright body position were served as auditory stimuli. During fMRI experiments, participants listen to the stimuli and pressed one of two buttons indicating the direction of the water flow (horizontal/vertical. Behavioral results indicated that participants could not differentiate between the congruent and the incongruent conditions. However, neuroimaging results showed that the congruent condition activated the planum temporale significantly more than the incongruent condition.

  16. Electron percolation in realistic models of carbon nanotube networks

    Science.gov (United States)

    Simoneau, Louis-Philippe; Villeneuve, Jérémie; Rochefort, Alain

    2015-09-01

    The influence of penetrable and curved carbon nanotubes (CNT) on the charge percolation in three-dimensional disordered CNT networks have been studied with Monte-Carlo simulations. By considering carbon nanotubes as solid objects but where the overlap between their electron cloud can be controlled, we observed that the structural characteristics of networks containing lower aspect ratio CNT are highly sensitive to the degree of penetration between crossed nanotubes. Following our efficient strategy to displace CNT to different positions to create more realistic statistical models, we conclude that the connectivity between objects increases with the hard-core/soft-shell radii ratio. In contrast, the presence of curved CNT in the random networks leads to an increasing percolation threshold and to a decreasing electrical conductivity at saturation. The waviness of CNT decreases the effective distance between the nanotube extremities, hence reducing their connectivity and degrading their electrical properties. We present the results of our simulation in terms of thickness of the CNT network from which simple structural parameters such as the volume fraction or the carbon nanotube density can be accurately evaluated with our more realistic models.

  17. An inexpensive yet realistic model for teaching vasectomy

    Directory of Open Access Journals (Sweden)

    Taylor M. Coe

    2015-04-01

    Full Text Available Purpose Teaching the no-scalpel vasectomy is important, since vasectomy is a safe, simple, and cost-effective method of contraception. This minimally invasive vasectomy technique involves delivering the vas through the skin with specialized tools. This technique is associated with fewer complications than the traditional incisional vasectomy (1. One of the most challenging steps is the delivery of the vas through a small puncture in the scrotal skin, and there is a need for a realistic and inexpensive scrotal model for beginning learners to practice this step. Materials and Methods After careful observation using several scrotal models while teaching residents and senior trainees, we developed a simplified scrotal model that uses only three components–bicycle inner tube, latex tubing, and a Penrose drain. Results This model is remarkably realistic and allows learners to practice a challenging step in the no-scalpel vasectomy. The low cost and simple construction of the model allows wide dissemination of training in this important technique. Conclusions We propose a simple, inexpensive model that will enable learners to master the hand movements involved in delivering the vas through the skin while mitigating the risks of learning on patients.

  18. Pharmacological modulation of arterial stiffness.

    LENUS (Irish Health Repository)

    Boutouyrie, Pierre

    2011-09-10

    Arterial stiffness has emerged as an important marker of cardiovascular risk in various populations and reflects the cumulative effect of cardiovascular risk factors on large arteries, which in turn is modulated by genetic background. Arterial stiffness is determined by the composition of the arterial wall and the arrangement of these components, and can be studied in humans non-invasively. Age and distending pressure are two major factors influencing large artery stiffness. Change in arterial stiffness with drugs is an important endpoint in clinical trials, although evidence for arterial stiffness as a therapeutic target still needs to be confirmed. Drugs that independently affect arterial stiffness include antihypertensive drugs, mostly blockers of the renin-angiotensin-aldosterone system, hormone replacement therapy and some antidiabetic drugs such as glitazones. While the quest continues for \\'de-stiffening drugs\\

  19. Pulmonary arterial hypertension : an update

    NARCIS (Netherlands)

    Hoendermis, E. S.

    2011-01-01

    Pulmonary arterial hypertension (PAH), defined as group 1 of the World Heart Organisation (WHO) classification of pulmonary hypertension, is an uncommon disorder of the pulmonary vascular system. It is characterised by an increased pulmonary artery pressure, increased pulmonary vascular resistance

  20. Human autonomic rhythms: vagal cardiac mechanisms in tetraplegic subjects

    Science.gov (United States)

    Koh, J.; Brown, T. E.; Beightol, L. A.; Ha, C. Y.; Eckberg, D. L.

    1994-01-01

    1. We studied eight young men (age range: 20-37 years) with chronic, clinically complete high cervical spinal cord injuries and ten age-matched healthy men to determine how interruption of connections between the central nervous system and spinal sympathetic motoneurones affects autonomic cardiovascular control. 2. Baseline diastolic pressures and R-R intervals (heart periods) were similar in the two groups. Slopes of R-R interval responses to brief neck pressure changes were significantly lower in tetraplegic than in healthy subjects, but slopes of R-R interval responses to steady-state arterial pressure reductions and increases were comparable. Plasma noradrenaline levels did not change significantly during steady-state arterial pressure reductions in tetraplegic patients, but rose sharply in healthy subjects. The range of arterial pressure and R-R interval responses to vasoactive drugs (nitroprusside and phenylephrine) was significantly greater in tetraplegic than healthy subjects. 3. Resting R-R interval spectral power at respiratory and low frequencies was similar in the two groups. During infusions of vasoactive drugs, low-frequency R-R interval spectral power was directly proportional to arterial pressure in tetraplegic patients, but was unrelated to arterial pressure in healthy subjects. Vagolytic doses of atropine nearly abolished both low- and respiratory-frequency R-R interval spectral power in both groups. 4. Our conclusions are as follows. First, since tetraplegic patients have significant levels of low-frequency arterial pressure and R-R interval spectral power, human Mayer arterial pressure waves may result from mechanisms that do not involve stimulation of spinal sympathetic motoneurones by brainstem neurones. Second, since in tetraplegic patients, low-frequency R-R interval spectral power is proportional to arterial pressure, it is likely to be mediated by a baroreflex mechanism. Third, since low-frequency R-R interval rhythms were nearly abolished

  1. Follow-up of renal and mesenteric artery revascularization with duplex ultrasonography

    Science.gov (United States)

    Taylor, David C.; Houston, Gordon T.M.; Anderson, Caroline; Jameson, Margot; Popatia, Shelley

    1996-01-01

    Objective To evaluate the long-term anatomic results of renal revascularization procedures using duplex ultrasonography. Design A case series. Setting A university-affiliated hospital. Patients Twenty-five patients who had undergone renal percutaneous transluminal angioplasty (PTA) (18 arteries), renal bypass (10 arteries) and mesenteric bypass (6 arteries). The mean follow-up was 22 months (range from 3 to 48 months) for those who underwent renal PTA, 23 months (range from 1.5 to 70 months) for those who underwent renal bypass and 34 months (range from 8 to 144 months) for those who underwent mesenteric bypass. Main Outcome Measures Patency rates for the three procedures as assessed by duplex ultrasonography. Results Duplex ultrasonography demonstrated patency without stenosis after renal and mesenteric artery revascularization in 14 arteries subjected to renal PTA, 9 arteries subjected to renal bypass and 6 arteries subjected to mesenteric bypass. Three arteries that had renal PTA had recurrent vessel stenosis and one had occlusion. One artery that had renal bypass showed occlusion. Conclusions Renal PTA, renal bypass and mesenteric bypass are durable procedures at 2 years of follow-up, and duplex ultrasonography is a valuable method for assessing the patency of arteries after renal and mesenteric revascularization. PMID:8599785

  2. Toward realistic pursuit-evasion using a roadmap-based approach

    KAUST Repository

    Rodriguez, Samuel; Denny, Jory; Burgos, Juan; Mahadevan, Aditya; Manavi, Kasra; Murray, Luke; Kodochygov, Anton; Zourntos, Takis; Amato, Nancy M.

    2011-01-01

    be applied to more realistic scenarios than are typically studied in most previous work, including agents moving in 3D environments such as terrains, multi-story buildings, and dynamic environments. We also support more realistic three-dimensional visibility

  3. Improving the Reasoning Ability of Elementary School Student through the Indonesian Realistic Mathematics Education

    Directory of Open Access Journals (Sweden)

    Muhamad Saleh

    2017-06-01

    Full Text Available By taking the role as a mentor and a facilitator, a teacher in the 4th grade of elementary school needs to look at the condition of the students in the concrete thinking stage. Learning process needs to be adjusted such that the abstract objects in mathematics can be represented through concrete objects as a bridge to enter the knowledge that the students already had, especially for the material of fraction. This research aims to analyze the achievement and the improvement of students’ mathematics reasoning ability through the implementation of Indonesian realistic mathematics education (PMRI approach. The research subject consisted of 51 students in the experiment group and 45 students in the control group which categorized into three levels (low, intermediate, and high. The result suggests that the achievement and the improvement of students’ reasoning ability in the mathematics learning using PMRI approach are better than the conventional learning.

  4. Realistic assessment of the radiological impact due to radionuclide releases to the terrestrial environment

    International Nuclear Information System (INIS)

    Proehl, G.

    2007-01-01

    Radioecological models are inherently associated with uncertainties, since ecological parameters are subject to a more or less pronounced variability; furthermore, the knowledge of the exposure conditions is - even in the best case - incomplete. To keep models simple and widely applicable and to avoid at the same time underestimations, parameters are selected with a conservative bias. However, conservative results are not appropriate for decision making and optimisation. To discuss the prevention of overly conservative models, in this paper, some selected processes are analysed that are involved in the transfer of radionuclides in the environment as e.g. interception of radionuclides deposited during precipitation by vegetation, systemic transport of radionuclides, migration of radionuclides in soil and speciation in soil. These processes are characterized, and it is discussed which factors should be integrated in modelling to achieve more realistic results. (author)

  5. A virtual auditory environment for investigating the auditory signal processing of realistic sounds

    DEFF Research Database (Denmark)

    Favrot, Sylvain Emmanuel; Buchholz, Jörg

    2008-01-01

    In the present study, a novel multichannel loudspeaker-based virtual auditory environment (VAE) is introduced. The VAE aims at providing a versatile research environment for investigating the auditory signal processing in real environments, i.e., considering multiple sound sources and room...... reverberation. The environment is based on the ODEON room acoustic simulation software to render the acoustical scene. ODEON outputs are processed using a combination of different order Ambisonic techniques to calculate multichannel room impulse responses (mRIR). Auralization is then obtained by the convolution...... the VAE development, special care was taken in order to achieve a realistic auditory percept and to avoid “artifacts” such as unnatural coloration. The performance of the VAE has been evaluated and optimized on a 29 loudspeaker setup using both objective and subjective measurement techniques....

  6. Predicting perceptual quality of images in realistic scenario using deep filter banks

    Science.gov (United States)

    Zhang, Weixia; Yan, Jia; Hu, Shiyong; Ma, Yang; Deng, Dexiang

    2018-03-01

    Classical image perceptual quality assessment models usually resort to natural scene statistic methods, which are based on an assumption that certain reliable statistical regularities hold on undistorted images and will be corrupted by introduced distortions. However, these models usually fail to accurately predict degradation severity of images in realistic scenarios since complex, multiple, and interactive authentic distortions usually appear on them. We propose a quality prediction model based on convolutional neural network. Quality-aware features extracted from filter banks of multiple convolutional layers are aggregated into the image representation. Furthermore, an easy-to-implement and effective feature selection strategy is used to further refine the image representation and finally a linear support vector regression model is trained to map image representation into images' subjective perceptual quality scores. The experimental results on benchmark databases present the effectiveness and generalizability of the proposed model.

  7. Peripheral Artery Disease

    Science.gov (United States)

    ... pressure High blood cholesterol Coronary heart disease Stroke Metabolic syndrome Screening and Prevention Taking action to control your risk factors can help prevent or delay peripheral artery disease (P.A.D.) and its complications. Know your family history of health problems related to P.A. ...

  8. Civilian popliteal artery injuries

    African Journals Online (AJOL)

    with reversed vein grafting in 68 patients, primary anastomosis in 33, prosthetic graft insertion in 11, ... patients underwent delayed amputation, giving an overall amputation rate of 37.5%. .... injury, level of arterial injury and type of repair had no significant ... patients, graft occlusion, and diseased crural vessels with poor run-.

  9. Pulmonary Arterial Hypertension

    Science.gov (United States)

    ... heart). This type of pulmonary hypertension was called “secondary pulmonary hypertension” but is now referred to as PH, because the cause is known to be from lung disease, heart disease, or chronic thromboemboli (blood clots). Pulmonary Arterial Hypertension (PAH) used to be ...

  10. Localized arterial occlusion following irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Kikuchi, S; Hasue, M [Japan Red Cross Medical Center, Tokyo; Fujiwara, M

    1982-04-01

    Occlusion of the major artery (the iliac artery in 2 cases and subclavicular artery in one) was reported, which occurred in association with bone necrosis 5 - 21 years after postoperative radiotherapy for malignant tumors (uterine cancer in 2 cases and mammary cancer in one).

  11. Attitude change in a realistic experiment: the effect of party membership and audience reaction during an interview with a Dutch politician

    NARCIS (Netherlands)

    Wiegman, O.

    1987-01-01

    In this realistic experiment, an interview with the leader of the Liberals in the Dutch Parliament was recorded in the presence of a live audience, which reacted in a positive, negative, or neutral way. It was shown to subjects of two opposing political parties, whose attitudes were to be changed by

  12. Transcatheter Coil Embolization of Splenic Artery Aneurysm

    International Nuclear Information System (INIS)

    Yamamoto, Satoshi; Hirota, Shozo; Maeda, Hiroaki; Achiwa, Sachiko; Arai, Keisuke; Kobayashi, Kaoru; Nakao, Norio

    2008-01-01

    The purpose of this study was to evaluate clinical results and technical problems of transcatheter coil embolization for splenic artery aneurysm. Subjects were 16 patients (8 men, 8 women; age range, 40-80 years) who underwent transcatheter embolization for splenic artery aneurysm (14 true aneurysms, 2 false aneurysms) at one of our hospitals during the period January 1997 through July 2005. Two aneurysms (12.5%) were diagnosed at the time of rupture. Multiple splenic aneurysms were found in seven patients. Aneurysms were classified by site as proximal (or strictly ostial) (n = 3), middle (n = 3), or hilar (n = 10). The indication for transcatheter arterial embolization was a false or true aneurysm 20 mm in diameter. Embolic materials were fibered coils and interlocking detachable coils. Embolization was performed by the isolation technique, the packing technique, or both. Technically, all aneurysms were devascularized without severe complications. Embolized aneurysms were 6-40 mm in diameter (mean, 25 mm). Overall, the primary technical success rate was 88% (14 of 16 patients). In the remaining 2 patients (12.5%), partial recanalization occurred, and re-embolization was performed. The secondary technical success rate was 100%. Seven (44%) of the 16 study patients suffered partial splenic infarction. Intrasplenic branching originating from the aneurysm was observed in five patients. We conclude that transcatheter coil embolization should be the initial treatment of choice for splenic artery aneurysm

  13. Circulating Anti-Elastin Antibody Levels and Arterial Disease Characteristics: Associations with Arterial Stiffness and Atherosclerosis.

    Science.gov (United States)

    Lee, Seung-Hyun; Shin, Kihyuk; Park, Sungha; Kang, Seok-Min; Choi, Donghoon; Lee, Seung-Hyo; Lee, Sang-Hak

    2015-11-01

    Elastin is a major arterial structural protein, and elastin-derived peptides are related to arterial change. We previously reported on a novel assay developed using aortic elastin peptides; however, its clinical implications remain unclear. In this study, we assessed whether anti-elastin antibody titers reflect the risk of coronary artery disease (CAD) or its characteristics. We included 174 CAD patients and 171 age- and sex-matched controls. Anti-elastin antibody titers were quantified by enzyme-linked immunosorbent assay. Parameters of arterial stiffness, including the augmentation index (AI) and heart-to-femoral pulse wave velocity (hfPWV), were measured non-invasively. The clinical and angiographic characteristics of CAD patients were also evaluated. Associations between anti-elastin levels and vascular characteristics were examined by linear regression analysis. The median blood level of anti-elastin was significantly lower in the CAD group than in the controls [197 arbitrary unit (a.u.) vs. 63 a.u., pelastin were significantly lower in men and in subjects with hypertension, diabetes mellitus, hyperlipidemia, or high hfPWV. Nevertheless, anti-elastin levels were not dependent on atherothrombotic events or the angiographic severity of CAD. In a multivariate analysis, male sex (β=-0.38, pelastin levels. Lower levels of anti-elastin are related to CAD. The association between antibody titers and CAD is linked to arterial stiffness rather than the advancement of atherosclerosis.

  14. Measurable realistic image-based 3D mapping

    Science.gov (United States)

    Liu, W.; Wang, J.; Wang, J. J.; Ding, W.; Almagbile, A.

    2011-12-01

    Maps with 3D visual models are becoming a remarkable feature of 3D map services. High-resolution image data is obtained for the construction of 3D visualized models.The3D map not only provides the capabilities of 3D measurements and knowledge mining, but also provides the virtual experienceof places of interest, such as demonstrated in the Google Earth. Applications of 3D maps are expanding into the areas of architecture, property management, and urban environment monitoring. However, the reconstruction of high quality 3D models is time consuming, and requires robust hardware and powerful software to handle the enormous amount of data. This is especially for automatic implementation of 3D models and the representation of complicated surfacesthat still need improvements with in the visualisation techniques. The shortcoming of 3D model-based maps is the limitation of detailed coverage since a user can only view and measure objects that are already modelled in the virtual environment. This paper proposes and demonstrates a 3D map concept that is realistic and image-based, that enables geometric measurements and geo-location services. Additionally, image-based 3D maps provide more detailed information of the real world than 3D model-based maps. The image-based 3D maps use geo-referenced stereo images or panoramic images. The geometric relationships between objects in the images can be resolved from the geometric model of stereo images. The panoramic function makes 3D maps more interactive with users but also creates an interesting immersive circumstance. Actually, unmeasurable image-based 3D maps already exist, such as Google street view, but only provide virtual experiences in terms of photos. The topographic and terrain attributes, such as shapes and heights though are omitted. This paper also discusses the potential for using a low cost land Mobile Mapping System (MMS) to implement realistic image 3D mapping, and evaluates the positioning accuracy that a measureable

  15. Radioactive waste management in Brazil: a realistic view

    International Nuclear Information System (INIS)

    Heilbron Filho, Paulo Fernando Lavalle; Perez Guerrero, Jesus Salvador; Xavier, Ana Maria

    2014-01-01

    The objective of this article is to present a realistic view of the main issues related to the management of radioactive waste in Brazil as well as a comprehensive picture of the regulatory waste management status in the country and internationally. Technical aspects that must be considered to ensure a safe construction of near surface disposal facilities for radioactive waste of low and medium levels of radiation are addressed. Different types of deposits, the basic regulatory issues involving the licensing of these facilities, the development of a financial compensation model for the Brazilian Municipalities where deposits are to be placed, the importance of the participation of the scientific community and society in the process of radioactive waste site selection and disposal, guidance for the application of the basic requirements of safety and radiation protection, the general safety aspects involved and the current actions for the disposal of radioactive waste in Brazil are highlighted. (author)

  16. Finite Time Blowup in a Realistic Food-Chain Model

    KAUST Repository

    Parshad, Rana; Ait Abderrahmane, Hamid; Upadhyay, Ranjit Kumar; Kumari, Nitu

    2013-01-01

    We investigate a realistic three-species food-chain model, with generalist top predator. The model based on a modified version of the Leslie-Gower scheme incorporates mutual interference in all the three populations and generalizes several other known models in the ecological literature. We show that the model exhibits finite time blowup in certain parameter range and for large enough initial data. This result implies that finite time blowup is possible in a large class of such three-species food-chain models. We propose a modification to the model and prove that the modified model has globally existing classical solutions, as well as a global attractor. We reconstruct the attractor using nonlinear time series analysis and show that it pssesses rich dynamics, including chaos in certain parameter regime, whilst avoiding blowup in any parameter regime. We also provide estimates on its fractal dimension as well as provide numerical simulations to visualise the spatiotemporal chaos.

  17. A Local Realistic Reconciliation of the EPR Paradox

    Science.gov (United States)

    Sanctuary, Bryan

    2014-03-01

    The exact violation of Bell's Inequalities is obtained with a local realistic model for spin. The model treats one particle that comprises a quantum ensemble and simulates the EPR data one coincidence at a time as a product state. Such a spin is represented by operators σx , iσy ,σz in its body frame rather than the usual set of σX ,σY ,σZ in the laboratory frame. This model, assumed valid in the absence of a measuring probe, contains both quantum polarizations and coherences. Each carries half the EPR correlation, but only half can be measured using coincidence techniques. The model further predicts the filter angles that maximize the spin correlation in EPR experiments.

  18. How to estimate realistic energy savings in Energy Performance Certificates

    DEFF Research Database (Denmark)

    Wittchen, Kim Bjarne; Altmann, Nagmeh; Berecová, Monika

    Given the fact that most MS use fixed or other kinds of default values as boundary condition input for energy performance calculations, it is not surprising that the calculated energy performance differs from the measured energy consumption. As a consequence, the calculated energy savings due...... stationary calculation tools using monthly average values. The optimum solution for energy performance certificates and calculating realistic energy savings is to have two calculations. One calculation, using default values to calculate the label itself, and one with actual input parameters for calculating...... energy performance before and after implementing energy saving measures. Actual values though, may be difficult to identify, so there is a need to make adaptations to reality easy. Even if actual values are available, there are still issues that cause calculated energy savings to differ from the obtained...

  19. Research of shot noise based on realistic nano-MOSFETs

    Directory of Open Access Journals (Sweden)

    Xiaofei Jia

    2017-05-01

    Full Text Available Experimental measurements and simulation results have shown that the dominant noise source of current noise changes from thermal noise to shot noise with scaling of MOSFET, and shot noise were suppressed by Fermi and Coulomb interactions. In this paper, Shot noise test system is established, and experimental results proved that shot noise were suppressed, and the expressions of shot noise in realistic nano-MOSFETs are derived with considering Fermi effect, Coulomb interaction and the combination of the both co-existence, respectively. On this basis, the variation of shot noise with voltage, temperature and source-drain doping were researched. The results we obtained are consistent with those from experiments and the theoretically explanation is given. At the same time, the shot noise test system is suitable for traditional nanoscale electronic components; the shot noise model is suitable for nanoscale MOSFET.

  20. From Minimal to Realistic Supersymmetric SU(5) Grand Unification

    CERN Document Server

    Altarelli, Guido; Masina, I; Altarelli, Guido; Feruglio, Ferruccio; Masina, Isabella

    2000-01-01

    We construct and discuss a "realistic" example of SUSY SU(5) GUT model, with an additional U(1) flavour symmetry, that is not plagued by the need of large fine tunings, like those associated with doublet-triplet splitting in the minimal model, and that leads to an acceptable phenomenology. This includes coupling unification with a value of alpha_s(m_Z) in much better agreement with the data than in the minimal version, an acceptable hierarchical pattern for fermion masses and mixing angles, also including neutrino masses and mixings, and a proton decay rate compatible with present limits (but the discovery of proton decay should be within reach of the next generation of experiments). In the neutrino sector the preferred solution is one with nearly maximal mixing both for atmospheric and solar neutrinos.

  1. Magnetic exchange at realistic CoO/Ni interfaces

    KAUST Repository

    Grytsiuk, Sergii

    2012-07-30

    We study the CoO/Ni interface by first principles calculations. Because the lattice mismatch is large, a realistic description requires a huge supercell. We investigate two interface configurations: in interface 1 the coupling between the Ni and Co atoms is mediated by O, whereas in interface 2 the Ni and Co atoms are in direct contact. We find that the magnetization (including the orbital moment) in interface 1 has a similar value as in bulk Ni but opposite sign, while in interface 2 it grows by 164%. The obtained magnetic moments can be explained by the local atomic environments. In addition, we find effects of charge transfer between the interface atoms. The Co 3d local density of states of interface 2 exhibits surprisingly small deviations from the corresponding bulk result, although the first coordination sphere is no longer octahedral. © Springer-Verlag 2012.

  2. Breaking with fun, educational and realistic learning games

    DEFF Research Database (Denmark)

    Duus Henriksen, Thomas

    2009-01-01

    are commonly conceived as means for staging learning processes, and that thinking learning games so has an inhibiting effect in regard to creating learning processes. The paper draws upon a qualitative study of participants' experiences with ‘the EIS Simulation', which is a computer-based learning game......This paper addresses the game conceptions and values that learning games inherit from regular gaming, as well as how they affect the use and development of learning games. Its key points concern the issues of thinking learning games as fun, educative and realistic, which is how learning games...... for teaching change management and change implementation. The EIS is played in groups, who share the game on a computer, and played by making change decisions in order to implement an IT system in an organisation. In this study, alternative participatory incentives, means for creating learning processes...

  3. Realistic control considerations for electromagnetically levitated urban transit vehicles

    Energy Technology Data Exchange (ETDEWEB)

    Billing, J R

    1976-04-01

    A discussion is given of realistic control considerations of suspension dynamics and vehicle/guideway interaction for electromagnetically-levitated urban transit vehicles in the context of revenue applications. The emphasis is on safety, reliability, and maintainability rather than performance. An example urban transit system is described, and the following considerations of dynamics and control are examined: stability, magnet force requirements, magnet airgap requirements, vehicle ride, and component failures. It is shown that it is a formidable problem to ensure suspension stability under all conditions; that operation on curves is a critical magnet and control system design case; that operation of the magnets in the non-linear regime is unavoidable and that component failures will be a major problem. However, good vehicle ride is to be expected. It is concluded that magnetic levitation suspension technology requires substantial development effort before it can be considered suitable for revenue operation.

  4. Generating realistic environments for cyber operations development, testing, and training

    Science.gov (United States)

    Berk, Vincent H.; Gregorio-de Souza, Ian; Murphy, John P.

    2012-06-01

    Training eective cyber operatives requires realistic network environments that incorporate the structural and social complexities representative of the real world. Network trac generators facilitate repeatable experiments for the development, training and testing of cyber operations. However, current network trac generators, ranging from simple load testers to complex frameworks, fail to capture the realism inherent in actual environments. In order to improve the realism of network trac generated by these systems, it is necessary to quantitatively measure the level of realism in generated trac with respect to the environment being mimicked. We categorize realism measures into statistical, content, and behavioral measurements, and propose various metrics that can be applied at each level to indicate how eectively the generated trac mimics the real world.

  5. Hydrostatic Equilibria of Rotating Stars with Realistic Equation of State

    Science.gov (United States)

    Yasutake, Nobutoshi; Fujisawa, Kotaro; Okawa, Hirotada; Yamada, Shoichi

    Stars rotate generally, but it is a non-trivial issue to obtain hydrostatic equilibria for rapidly rotating stars theoretically, especially for baroclinic cases, in which the pressure depends not only on the density, but also on the temperature and compositions. It is clear that the stellar structures with realistic equation of state are the baroclinic cases, but there are not so many studies for such equilibria. In this study, we propose two methods to obtain hydrostatic equilibria considering rotation and baroclinicity, namely the weak-solution method and the strong-solution method. The former method is based on the variational principle, which is also applied to the calculation of the inhomogeneous phases, known as the pasta structures, in crust of neutron stars. We found this method might break the balance equation locally, then introduce the strong-solution method. Note that our method is formulated in the mass coordinate, and it is hence appropriated for the stellar evolution calculations.

  6. Using Concrete and Realistic Data in Evaluating Initial Visualization Designs

    DEFF Research Database (Denmark)

    Knudsen, Søren; Pedersen, Jeppe Gerner; Herdal, Thor

    2016-01-01

    We explore means of designing and evaluating initial visualization ideas, with concrete and realistic data in cases where data is not readily available. Our approach is useful in exploring new domains and avenues for visualization, and contrasts other visualization work, which typically operate...... under the assumption that data has already been collected, and is ready to be visualized. We argue that it is sensible to understand data requirements and evaluate the potential value of visualization before devising means of automatic data collection. We base our exploration on three cases selected...... the design case and problem, the manner in which we collected data, and the findings obtained from evaluations. Afterwards, we describe four factors of our data collection approach, and discuss potential outcomes from it....

  7. Simulating realistic implementations of spin field effect transistor

    Science.gov (United States)

    Gao, Yunfei; Lundstrom, Mark S.; Nikonov, Dmitri E.

    2011-04-01

    The spin field effect transistor (spinFET), consisting of two ferromagnetic source/drain contacts and a Si channel, is predicted to have outstanding device and circuit performance. We carry out a rigorous numerical simulation of the spinFET based on the nonequilibrium Green's function formalism self-consistently coupled with a Poisson solver to produce the device I-V characteristics. Good agreement with the recent experiments in terms of spin injection, spin transport, and the magnetoresistance ratio (MR) is obtained. We include factors crucial for realistic devices: tunneling through a dielectric barrier, and spin relaxation at the interface and in the channel. Using these simulations, we suggest ways of optimizing the device. We propose that by choosing the right contact material and inserting tunnel oxide barriers between the source/drain and channel to filter different spins, the MR can be restored to ˜2000%, which would be beneficial to the reconfigurable logic circuit application.

  8. Is islet transplantation a realistic approach to curing diabetes?

    Science.gov (United States)

    Jin, Sang-Man; Kim, Kwang-Won

    2017-01-01

    Since the report of type 1 diabetes reversal in seven consecutive patients by the Edmonton protocol in 2000, pancreatic islet transplantation has been reappraised based on accumulated clinical evidence. Although initially expected to therapeutically target long-term insulin independence, islet transplantation is now indicated for more specific clinical benefits. With the long-awaited report of the first phase 3 clinical trial in 2016, allogeneic islet transplantation is now transitioning from an experimental to a proven therapy for type 1 diabetes with problematic hypoglycemia. Islet autotransplantation has already been therapeutically proven in chronic pancreatitis with severe abdominal pain refractory to conventional treatments, and it holds promise for preventing diabetes after partial pancreatectomy due to benign pancreatic tumors. Based on current evidence, this review focuses on islet transplantation as a realistic approach to treating diabetes.

  9. Realistic limitations of detecting planets around young active stars

    Directory of Open Access Journals (Sweden)

    Pinfield D.

    2013-04-01

    Full Text Available Current planet hunting methods using the radial velocity method are limited to observing middle-aged main-sequence stars where the signatures of stellar activity are much less than on young stars that have just arrived on the main-sequence. In this work we apply our knowledge from the surface imaging of these young stars to place realistic limitations on the possibility of detecting orbiting planets. In general we find that the magnitude of the stellar jitter is directly proportional to the stellar vsini. For G and K dwarfs, we find that it is possible, for models with high stellar activity and low stellar vsini, to be able to detect a 1 MJupiter mass planet within 50 epochs of observations and for the M dwarfs it is possible to detect a habitable zone Earth-like planet in 10s of observational epochs.

  10. Resolving conflict realistically in today's health care environment.

    Science.gov (United States)

    Smith, S B; Tutor, R S; Phillips, M L

    2001-11-01

    Conflict is a natural part of human interaction, and when properly addressed, results in improved interpersonal relationships and positive organizational culture. Unchecked conflict may escalate to verbal and physical violence. Conflict that is unresolved creates barriers for people, teams, organizational growth, and productivity, leading to cultural disintegration within the establishment. By relying on interdependence and professional collaboration, all parties involved grow and, in turn, benefit the organization and population served. When used in a constructive manner, conflict resolution can help all parties involved see the whole picture, thus allowing freedom for growth and change. Conflict resolution is accomplished best when emotions are controlled before entering into negotiation. Positive confrontation, problem solving, and negotiation are processes used to realistically resolve conflict. Everyone walks away a winner when conflict is resolved in a positive, professional manner (Stone, 1999).

  11. Realistic electrostatic potentials in a neutron star crust

    International Nuclear Information System (INIS)

    Ebel, Claudio; Mishustin, Igor; Greiner, Walter

    2015-01-01

    We study the electrostatic properties of inhomogeneous nuclear matter which can be formed in the crusts of neutron stars or in supernova explosions. Such matter is represented by Wigner–Seitz cells of different geometries (spherical, cylindrical, cartesian), which contain nuclei, free neutrons and electrons under the conditions of electrical neutrality. Using the Thomas–Fermi approximation, we have solved the Poisson equation for the electrostatic potential and calculated the corresponding electron density distributions in individual cells. The calculations are done for different shapes and sizes of the cells and different average baryon densities. The electron-to-baryon fraction was fixed at 0.3. Using realistic electron distributions leads to a significant reduction in electrostatic energy and electron chemical potential. (paper)

  12. Finite Time Blowup in a Realistic Food-Chain Model

    KAUST Repository

    Parshad, Rana

    2013-05-19

    We investigate a realistic three-species food-chain model, with generalist top predator. The model based on a modified version of the Leslie-Gower scheme incorporates mutual interference in all the three populations and generalizes several other known models in the ecological literature. We show that the model exhibits finite time blowup in certain parameter range and for large enough initial data. This result implies that finite time blowup is possible in a large class of such three-species food-chain models. We propose a modification to the model and prove that the modified model has globally existing classical solutions, as well as a global attractor. We reconstruct the attractor using nonlinear time series analysis and show that it pssesses rich dynamics, including chaos in certain parameter regime, whilst avoiding blowup in any parameter regime. We also provide estimates on its fractal dimension as well as provide numerical simulations to visualise the spatiotemporal chaos.

  13. Electron distribution in polar heterojunctions within a realistic model

    Energy Technology Data Exchange (ETDEWEB)

    Tien, Nguyen Thanh, E-mail: thanhtienctu@gmail.com [College of Natural Science, Can Tho University, 3-2 Road, Can Tho City (Viet Nam); Thao, Dinh Nhu [Center for Theoretical and Computational Physics, College of Education, Hue University, 34 Le Loi Street, Hue City (Viet Nam); Thao, Pham Thi Bich [College of Natural Science, Can Tho University, 3-2 Road, Can Tho City (Viet Nam); Quang, Doan Nhat [Institute of Physics, Vietnamese Academy of Science and Technology, 10 Dao Tan Street, Hanoi (Viet Nam)

    2015-12-15

    We present a theoretical study of the electron distribution, i.e., two-dimensional electron gas (2DEG) in polar heterojunctions (HJs) within a realistic model. The 2DEG is confined along the growth direction by a triangular quantum well with a finite potential barrier and a bent band figured by all confinement sources. Therein, interface polarization charges take a double role: they induce a confining potential and, furthermore, they can make some change in other confinements, e.g., in the Hartree potential from ionized impurities and 2DEG. Confinement by positive interface polarization charges is necessary for the ground state of 2DEG existing at a high sheet density. The 2DEG bulk density is found to be increased in the barrier, so that the scattering occurring in this layer (from interface polarization charges and alloy disorder) becomes paramount in a polar modulation-doped HJ.

  14. Magnetic exchange at realistic CoO/Ni interfaces

    KAUST Repository

    Grytsyuk, Sergiy; Cossu, Fabrizio; Schwingenschlö gl, Udo

    2012-01-01

    We study the CoO/Ni interface by first principles calculations. Because the lattice mismatch is large, a realistic description requires a huge supercell. We investigate two interface configurations: in interface 1 the coupling between the Ni and Co atoms is mediated by O, whereas in interface 2 the Ni and Co atoms are in direct contact. We find that the magnetization (including the orbital moment) in interface 1 has a similar value as in bulk Ni but opposite sign, while in interface 2 it grows by 164%. The obtained magnetic moments can be explained by the local atomic environments. In addition, we find effects of charge transfer between the interface atoms. The Co 3d local density of states of interface 2 exhibits surprisingly small deviations from the corresponding bulk result, although the first coordination sphere is no longer octahedral. © Springer-Verlag 2012.

  15. Radioactive waste management in Brazil: a realistic view

    Energy Technology Data Exchange (ETDEWEB)

    Heilbron Filho, Paulo Fernando Lavalle; Perez Guerrero, Jesus Salvador, E-mail: paulo@cnen.gov.br, E-mail: jperez@cnen.gov.br [Comissao Nacional de Energia Nuclear (CNEN), Rio de Janeiro, RJ (Brazil); Xavier, Ana Maria, E-mail: axavier@cnen.gov.br [Comissao Nacional de Energia Nuclear (ESPOA/CNEN-RS), Porto Alegre, RS (Brazil)

    2014-07-01

    The objective of this article is to present a realistic view of the main issues related to the management of radioactive waste in Brazil as well as a comprehensive picture of the regulatory waste management status in the country and internationally. Technical aspects that must be considered to ensure a safe construction of near surface disposal facilities for radioactive waste of low and medium levels of radiation are addressed. Different types of deposits, the basic regulatory issues involving the licensing of these facilities, the development of a financial compensation model for the Brazilian Municipalities where deposits are to be placed, the importance of the participation of the scientific community and society in the process of radioactive waste site selection and disposal, guidance for the application of the basic requirements of safety and radiation protection, the general safety aspects involved and the current actions for the disposal of radioactive waste in Brazil are highlighted. (author)

  16. Modeling and Analysis of Realistic Fire Scenarios in Spacecraft

    Science.gov (United States)

    Brooker, J. E.; Dietrich, D. L.; Gokoglu, S. A.; Urban, D. L.; Ruff, G. A.

    2015-01-01

    An accidental fire inside a spacecraft is an unlikely, but very real emergency situation that can easily have dire consequences. While much has been learned over the past 25+ years of dedicated research on flame behavior in microgravity, a quantitative understanding of the initiation, spread, detection and extinguishment of a realistic fire aboard a spacecraft is lacking. Virtually all combustion experiments in microgravity have been small-scale, by necessity (hardware limitations in ground-based facilities and safety concerns in space-based facilities). Large-scale, realistic fire experiments are unlikely for the foreseeable future (unlike in terrestrial situations). Therefore, NASA will have to rely on scale modeling, extrapolation of small-scale experiments and detailed numerical modeling to provide the data necessary for vehicle and safety system design. This paper presents the results of parallel efforts to better model the initiation, spread, detection and extinguishment of fires aboard spacecraft. The first is a detailed numerical model using the freely available Fire Dynamics Simulator (FDS). FDS is a CFD code that numerically solves a large eddy simulation form of the Navier-Stokes equations. FDS provides a detailed treatment of the smoke and energy transport from a fire. The simulations provide a wealth of information, but are computationally intensive and not suitable for parametric studies where the detailed treatment of the mass and energy transport are unnecessary. The second path extends a model previously documented at ICES meetings that attempted to predict maximum survivable fires aboard space-craft. This one-dimensional model implies the heat and mass transfer as well as toxic species production from a fire. These simplifications result in a code that is faster and more suitable for parametric studies (having already been used to help in the hatch design of the Multi-Purpose Crew Vehicle, MPCV).

  17. Reliability of peripheral arterial tonometry in patients with heart failure, diabetic nephropathy and arterial hypertension.

    Science.gov (United States)

    Weisrock, Fabian; Fritschka, Max; Beckmann, Sebastian; Litmeier, Simon; Wagner, Josephine; Tahirovic, Elvis; Radenovic, Sara; Zelenak, Christine; Hashemi, Djawid; Busjahn, Andreas; Krahn, Thomas; Pieske, Burkert; Dinh, Wilfried; Düngen, Hans-Dirk

    2017-08-01

    Endothelial dysfunction plays a major role in cardiovascular diseases and pulse amplitude tonometry (PAT) offers a non-invasive way to assess endothelial dysfunction. However, data about the reliability of PAT in cardiovascular patient populations are scarce. Thus, we evaluated the test-retest reliability of PAT using the natural logarithmic transformed reactive hyperaemia index (LnRHI). Our cohort consisted of 91 patients (mean age: 65±9.7 years, 32% female), who were divided into four groups: those with heart failure with preserved ejection fraction (HFpEF) ( n=25), heart failure with reduced ejection fraction (HFrEF) ( n=22), diabetic nephropathy ( n=21), and arterial hypertension ( n=23). All subjects underwent two separate PAT measurements at a median interval of 7 days (range 4-14 days). LnRHI derived by PAT showed good reliability in subjects with diabetic nephropathy (intra-class correlation (ICC) = 0.863) and satisfactory reliability in patients with both HFpEF (ICC = 0.557) and HFrEF (ICC = 0.576). However, in subjects with arterial hypertension, reliability was poor (ICC = 0.125). We demonstrated that PAT is a reliable technique to assess endothelial dysfunction in adults with diabetic nephropathy, HFpEF or HFrEF. However, in subjects with arterial hypertension, we did not find sufficient reliability, which can possibly be attributed to variations in heart rate and the respective time of the assessments. Clinical Trial Registration Identifier: NCT02299960.

  18. Arterial And Ventricular Elastance And Ventriculo-arterial Coupling In Asthmatic Children

    International Nuclear Information System (INIS)

    Ozkan, E. A.; Gecit, A.; Beysel, P.

    2016-01-01

    Objective: To compare arterial and ventricular end-systolic elastance and ventriculo-arterial coupling between asthma and healthy children and correlate these all three parameters with pulmonary function tests in subjects with asthma. Study Design: Across-sectional analytical study. Place and Duration of Study: Department of Pediatrics, Bozok University Medical Faculty,Yozgat, Turkey, from January 2012 to November 2014. Methodology: Transthoracic and Doppler echocardiography and pulmonary function tests in patients with asthma aged 7 - 12 years and control subjects. Forty stable asthma patients on prophylactic inhaled corticosteroids and 97 healthy subjects were investigated. Both groups were matched for age, gender, blood pressure, heart rate, body surface area, echocardiographic parameters and pulmonary function tests. Results: There was no difference regarding left ventricular elastance at end-systole derived by single beat/body surface area (Ees(sb)/BSA) between asthmatic patients and healthy children (2.59 ±1.29 mmHg/ml/m2, 2.43 ±1.28 mmHg/ml/m2 respectively, p=0.504), arterial elastance/BSA(Ea/BSA) (2.10 ±0.97, 1.75 ±0.89 respectively, p=0.041), and ventriculoarterial coupling (VAC) (0.83 ±0.13, 0.74 ±0.13, respectively, p < 0.001) were higher in asthmatic group than controls. There was no correlation between Ea, Ees (sb), VAC and pulmonary function tests. Conclusion: Arterial elastance increase and stiffness decrease in asthmatic patients. This may be due to using prophylactic inhaled corticosteroids. Using inhaled corticosteroids have protective effects against atherosclerosis. As a result of this higher arterial elastance, asthmatic children had higher VAC resulting in less efficient cardiovascular function. (author)

  19. Artery Soft-Tissue Modelling for Stent Implant Training System

    Directory of Open Access Journals (Sweden)

    Giovanni Aloisio

    2004-08-01

    Full Text Available Virtual reality technology can be utilised to provide new systematic training methods for surgical procedures. Our aim is to build a simulator that allows medical students to practice the coronary stent implant procedure and avoids exposing patients to risks. The designed simulation system consists of a virtual environment and a haptic interface, in order to provide both the visualization of the coronary arteries and the tactile and force feedback generated during the interactions of the surgical instruments in the virtual environment. Since the arteries are soft tissues, their shape may change during an operation; for this reason physical modelling of the organs is necessary to render their behaviour under the influence of surgeon's instruments. The idea is to define a model that computes the displacement of the tissue versus time; from the displacement it is possible to calculate the response of the tissue to the surgical tool external stimuli. Information about tools displacements and tissue responses are also used to graphically model the artery wall and virtual surgical instrument deformations generated as a consequence of their coming into contact. In order to obtain a realistic simulation, the Finite Element Method has been used to model the soft tissues of the artery, using linear elasticity to reduce computational time and speed up interaction rates.

  20. Right ventricle performances with echocardiography and 99mTc myocardial perfusion imaging in pulmonary arterial hypertension patients.

    Science.gov (United States)

    Liu, Jie; Fei, Lei; Huang, Guang-Qing; Shang, Xiao-Ke; Liu, Mei; Pei, Zhi-Jun; Zhang, Yong-Xue

    2018-05-01

    Right heart catheterization is commonly used to measure right ventricle hemodynamic parameters and is the gold standard for pulmonary arterial hypertension diagnosis; however, it is not suitable for patients' long-term follow-up. Non-invasive echocardiography and nuclear medicine have been applied to measure right ventricle anatomy and function, but the guidelines for the usefulness of clinical parameters remain to be established. The goal of this study is to identify reliable clinical parameters of right ventricle function in pulmonary arterial hypertension patients and analyze the relationship of these clinical parameters with the disease severity of pulmonary arterial hypertension. In this study, 23 normal subjects and 23 pulmonary arterial hypertension patients were recruited from January 2015 to March 2016. Pulmonary arterial hypertension patients were classified into moderate and severe pulmonary arterial hypertension groups according to their mean pulmonary arterial pressure levels. All the subjects were subjected to physical examination, chest X-ray, 12-lead electrocardiogram, right heart catheterization, two-dimensional echocardiography, and technetium 99m ( 99m Tc) myocardial perfusion imaging. Compared to normal subjects, the right heart catheterization indexes including right ventricle systolic pressure, right ventricle end diastolic pressure, pulmonary artery systolic pressure, pulmonary artery diastolic pressure, pulmonary vascular resistance, and right ventricle end systolic pressure increased in pulmonary arterial hypertension patients and were correlated with mean pulmonary arterial pressure levels. Echocardiography parameters, including tricuspid regurgitation peak velocity, tricuspid regurgitation pressure gradient, tricuspid annular plane systolic excursion and fractional area, right ventricle-myocardial performance index, were significantly associated with the mean pulmonary arterial pressure levels in pulmonary arterial hypertension patients

  1. Caliber-Persistent Artery

    Directory of Open Access Journals (Sweden)

    Sabrina Araújo Pinho Costa

    2015-01-01

    Full Text Available Caliber-persistent artery (CPLA of the lip is a common vascular anomaly in which a main arterial branch extends to the surface of the mucous tissue with no reduction in its diameter. It usually manifests as pulsatile papule, is easily misdiagnosed, and is observed more frequently among older people, suggesting that its development may involve a degenerative process associated with aging; CPLA is also characterized by the loss of tone of the adjacent supporting connective tissue. Although the diagnosis is clinical, high-resolution Doppler ultrasound is a useful noninvasive tool for evaluating the lesion. This report describes the case of a 58-year-old male patient who complained of a lesion of the lower lip with bleeding and recurrent ulceration. The patient was successfully treated in our hospital after a diagnosis of CPLA and is currently undergoing a clinical outpatient follow-up with no complaints.

  2. Vertebral basilar artery dissections

    International Nuclear Information System (INIS)

    Zimmerman, R.A.; Bilaniuk, L.T.; Hackney, D.B.; Grossman, R.I.; Goldberg, H.I.; Atlas, S.W.

    1988-01-01

    Eleven patients (ten male, one female; range, 2-56 years) presented with posterior circulation ischemic symptoms and were evaluated with computed tomography (CT) (eta=11), arteriography (eta=11), and magnetic resonance (MR) imaging (eta=6). Angiography showed dissection of a vertebral artery (eta=8), a basilar artery (eta=1), or a combination of both (eta=2). On CT and/or MR images, infarctions were demonstrated in ten of 11 cases. Most frequently involved were the thalmus (eta=7), cerebellum (eta=6), occipital lobes (eta=4), and pons (eta=3). The site of infarction did not correlate with the side or site of angiographic abnormality. In six cases evaluated by all modalities, MR imaging showed more extensive and widespread infarction than did CT and also showed whether or not the infarcts were hemorrhagic. MR imaging was able to demonstrate the presence of intramural dissecting hematoma prior to angiography and to indicate whether or not flow was reconstituted on follow-up examination

  3. MR manifestations of vertebral artery injuries in cervical spine trauma

    Energy Technology Data Exchange (ETDEWEB)

    Yu, Jeong Sik; Chung, Tae Sub; Kim, Young Soo; Cho, Yong Eun; Kang, Byung Chul; Kim, Dong Ik [Yonsei Univ. College of Medicine, Seoul (Korea, Republic of)

    1996-11-01

    To assess the diagnostic efficacy of magnetic resonance (MR) imaging in the detection of a vertebral artery injury occurring from major cervical spine trauma. Conventional MR findings of 63 patients and 63 control subjects were compared to detect a possible change in the vertebral arteries resulted from trauma. Plain films, CT and clinical records were also reviewed to correlate the degree of cervical spine injury with vascular change. Nine cases of absent flow signals in vessel lumen were observed in eight patients and one was observed in the control group. Patients more frequently demonstrated other abnormalities such as intraluminal linear signals (n=3) or focal luminal narrowing (n=9) but there was no statistical significance. There was a close relationship between degree of cord damage and occlusion of the vertebral artery. Conventional MR imaging is useful in the detection of vertebral artery occlusion resulting from cervical spine trauma.

  4. Surgical neuroangiography. Vol. 1: Functional anatomy of craniofacial arteries

    International Nuclear Information System (INIS)

    Lasjaunias, P.; Berenstein, A.

    1987-01-01

    The contents of this book are: Arterial Anatomy: Introduction. - The Internal Maxillary System. - The Pharyngo-occipital System. - The Upper Cervical Vertebral Column: The Cervical Arteries. - The Musculocutaneous Elements of the Head and Mouth. - Thyrolaryngeal Arteries. - The Transosseous Peripheral Nervous System Arterial Supply. - Dangerous Vessels. - Collateral Circulation. - The Pharyngoocipital Collateral Pattern. - The Internal Maxillary Collateral Pattern. - The Linguofacial Collateral Pattern. - Multiple Constraints and Chronology of the Collateral Response. - Angiographic Protocols. - Angiographic Protocol of the Parasellar Region. - Angiographic Protocol of the Posterior Base of the Skull. - Angiographic Protocol of the Carotid Region. - Angiographic Protocol of the Nasomaxillaary Region. - Angiographic Protocol of the Maxillomandibular Region. - Angiographic Protocol of the Temporofacial and Scalp Region. - Angiographic Protocol of the Thyrolaryngeal Region. - References. - Subject Index

  5. Popliteal artery entrapment syndrome

    International Nuclear Information System (INIS)

    Klooster, N.J.J.; Janevski, B.K.; Kitslaar, P.

    1988-01-01

    Two patients with unilateral popliteal artery entrapment syndrome (PAES) are reported. The importance of diligence in angiographic diagnosis and recognition of the so-called 'functional' PAES group as a separate entity are stressed. It is inferred from our material that a surgical approach for PAES is to be advocated since surgical release of the entrapment can lead to complete resolution of symptoms regardless of aetiology. (orig.) [de

  6. Innominate artery war injury

    Directory of Open Access Journals (Sweden)

    Ilić Radoje

    2005-01-01

    Full Text Available Aim. A case is reported of successfully surgically treated explosive war injury to the innominate artery. Case report. A 26 - year-old soldier was injured in combat by a fragment of mortar shell. In the field hospital, the wound gauze packing was applied, followed by orotracheal intubation and thoracic drainage. The soldier was admitted to MMA six hours later. Physical examination, on admission, revealed huge swelling of the neck, the absence of pulse in the right arm and the right common carotid artery. Chest x-ray revealed hemopneumothorax of the right side and the foreign metal body in the projection of the right sternoclavicular joint. Due to the suspicion of large vessel injury, a median sternotomy was immediately performed. Surgery revealed disrupted bifurcation of the right innominate artery, so the ligation was performed. Aortography was performed postoperatively, followed by the reconstruction of innominate bifurcation with synthetic grafts. Control aortography showed good graft patency, and the patient was discharged from the hospital in good general condition with palpable pulses and mild anisocoria as a sole neurological sequela. Conclusion. A rare and life-threatening injury was successfully managed, mainly due to the rational treatment carried out in the field hospital that helped the injured to survive and arrive to the institution capable of performing the most sophisticated diagnostic and therapeutic procedures.

  7. Renal artery pseudoaneurysm

    Directory of Open Access Journals (Sweden)

    Luiz Inácio Roman

    Full Text Available Abstract The renal artery pseudoaneurysm embody a rare vascular complication coming of percutaneous procedures, renal biopsy, nephrectomy, penetrating traumas and more rarely blunt traumas. The clinical can be vary according the patient, the haematuria is the symptom more commom. Is necessary a high level of clinical suspicion for your diagnosis, this can be elucidated by through complementary exams as the eco-color Doppler and the computed tomography scan (CT. This report is a case of a patient submitted a right percutaneous renal biopsy and that, after the procedure started with macroscopic haematuria, urinary tenesmus and hypogastric pain. The diagnosis of pseudoaneurysm was given after one week of evolution when the patient was hospitalized because gross haematuria, tachycardia, hypotension and hypochondrium pain. In the angiotomography revealed a focal dilation of the accessory right renal inferior polar artery, dilation of renal pelvis and all the ureteral course with presence hyperdenso material (clots inside the middle third of the ureter. The treatment for the majority of this cases are conservative, through arterial embolization, indicated for thouse of smaller dimensions in patients who are hemodynamically stable. However, it was decided by clinical treatment with aminocaproic acid 1 g, according to previous studies for therapy of haematuria. The patient received discharge without evidence of macroscopic haematuria and with normal renal ultrasound, following ambulatory care.

  8. Coronary Artery Anomalies in Animals

    Directory of Open Access Journals (Sweden)

    Brian A. Scansen

    2017-04-01

    Full Text Available Coronary artery anomalies represent a disease spectrum from incidental to life-threatening. Anomalies of coronary artery origin and course are well-recognized in human medicine, but have received limited attention in veterinary medicine. Coronary artery anomalies are best described in the dog, hamster, and cow though reports also exist in the horse and pig. The most well-known anomaly in veterinary medicine is anomalous coronary artery origin with a prepulmonary course in dogs, which limits treatment of pulmonary valve stenosis. A categorization scheme for coronary artery anomalies in animals is suggested, dividing these anomalies into those of major or minor clinical significance. A review of coronary artery development, anatomy, and reported anomalies in domesticated species is provided and four novel canine examples of anomalous coronary artery origin are described: an English bulldog with single left coronary ostium and a retroaortic right coronary artery; an English bulldog with single right coronary ostium and transseptal left coronary artery; an English bulldog with single right coronary ostium and absent left coronary artery with a prepulmonary paraconal interventricular branch and an interarterial circumflex branch; and a mixed-breed dog with tetralogy of Fallot and anomalous origin of all coronary branches from the brachiocephalic trunk. Coronary arterial fistulae are also described including a coronary cameral fistula in a llama cria and an English bulldog with coronary artery aneurysm and anomalous shunting vessels from the right coronary artery to the pulmonary trunk. These examples are provided with the intent to raise awareness and improve understanding of such defects.

  9. Convective aggregation in realistic convective-scale simulations

    Science.gov (United States)

    Holloway, Christopher E.

    2017-06-01

    To investigate the real-world relevance of idealized-model convective self-aggregation, five 15 day cases of real organized convection in the tropics are simulated. These include multiple simulations of each case to test sensitivities of the convective organization and mean states to interactive radiation, interactive surface fluxes, and evaporation of rain. These simulations are compared to self-aggregation seen in the same model configured to run in idealized radiative-convective equilibrium. Analysis of the budget of the spatial variance of column-integrated frozen moist static energy shows that control runs have significant positive contributions to organization from radiation and negative contributions from surface fluxes and transport, similar to idealized runs once they become aggregated. Despite identical lateral boundary conditions for all experiments in each case, systematic differences in mean column water vapor (CWV), CWV distribution shape, and CWV autocorrelation length scale are found between the different sensitivity runs, particularly for those without interactive radiation, showing that there are at least some similarities in sensitivities to these feedbacks in both idealized and realistic simulations (although the organization of precipitation shows less sensitivity to interactive radiation). The magnitudes and signs of these systematic differences are consistent with a rough equilibrium between (1) equalization due to advection from the lateral boundaries and (2) disaggregation due to the absence of interactive radiation, implying disaggregation rates comparable to those in idealized runs with aggregated initial conditions and noninteractive radiation. This points to a plausible similarity in the way that radiation feedbacks maintain aggregated convection in both idealized simulations and the real world.Plain Language SummaryUnderstanding the processes that lead to the organization of tropical rainstorms is an important challenge for weather

  10. Effective realistic interactions for low momentum Hilbert spaces

    International Nuclear Information System (INIS)

    Weber, Dennis

    2012-01-01

    Realistic nucleon-nucleon potentials are an essential ingredient of modern microscopic many-body calculations. These potentials can be represented in two different ways: operator representation or matrix element representation. In operator representation the potential is represented by a set of quantum mechanical operators while in matrix element representation it is defined by the matrix elements in a given basis. Many modern potentials are constructed directly in matrix element representation. While the matrix element representation can be calculated from the operator representation, the determination of the operator representation from the matrix elements is more difficult. Some methods to solve the nuclear many-body problem, such as Fermionic Molecular Dynamics (FMD) or the Green's Function Monte Carlo (GFMC) method, however require explicitly the operator representation of the potential, as they do not work in a fixed many-body basis. It is therefore desirable to derive an operator representation also for the interactions given by matrix elements. In this work a method is presented which allows the derivation of an approximate operator representation starting from the momentum space partial wave matrix elements of the interaction. For that purpose an ansatz for the operator representation is chosen. The parameters in the ansatz are determined by a fit to the partial wave matrix elements. Since a perfect reproduction of the matrix elements in general cannot be achieved with a finite number of operators and the quality of the results depends on the choice of the ansatz, the obtained operator representation is tested in nuclear many-body calculations and the results are compared with those from the initial interaction matrix elements. For the calculation of the nucleon-nucleon scattering phase shifts and the deuteron properties a computer code written within this work is used. For larger nuclei the No Core Shell Model (NCSM) and FMD are applied. The described

  11. Toward developing more realistic groundwater models using big data

    Science.gov (United States)

    Vahdat Aboueshagh, H.; Tsai, F. T. C.; Bhatta, D.; Paudel, K.

    2017-12-01

    Rich geological data is the backbone of developing realistic groundwater models for groundwater resources management. However, constructing realistic groundwater models can be challenging due to inconsistency between different sources of geological, hydrogeological and geophysical data and difficulty in processing big data to characterize the subsurface environment. This study develops a framework to utilize a big geological dataset to create a groundwater model for the Chicot Aquifer in the southwestern Louisiana, which borders on the Gulf of Mexico at south. The Chicot Aquifer is the principal source of fresh water in southwest Louisiana, underlying an area of about 9,000 square miles. Agriculture is the largest groundwater consumer in this region and overpumping has caused significant groundwater head decline and saltwater intrusion from the Gulf and deep formations. A hydrostratigraphy model was constructed using around 29,000 electrical logs and drillers' logs as well as screen lengths of pumping wells through a natural neighbor interpolation method. These sources of information have different weights in terms of accuracy and trustworthy. A data prioritization procedure was developed to filter untrustworthy log information, eliminate redundant data, and establish consensus of various lithological information. The constructed hydrostratigraphy model shows 40% sand facies, which is consistent with the well log data. The hydrostratigraphy model confirms outcrop areas of the Chicot Aquifer in the north of the study region. The aquifer sand formation is thinning eastward to merge into Atchafalaya River alluvial aquifer and coalesces to the underlying Evangeline aquifer. A grid generator was used to convert the hydrostratigraphy model into a MODFLOW grid with 57 layers. A Chicot groundwater model was constructed using the available hydrologic and hydrogeological data for 2004-2015. Pumping rates for irrigation wells were estimated using the crop type and acreage

  12. Interventional radiology. Vol. 1. Endovascular reconstruction of the pelvic arteries in case of peripheral arterial occlusion

    International Nuclear Information System (INIS)

    Berger, H.; Pickel, P.; Weiss, W.

    2003-01-01

    Catheters and stents are effective techniques for treating arterial occlusion and make high demands on the medical experts, which must be highly competent and able to take quick decisions. This CD-ROM offers multimedia information including video and animation to explain the correct use of these methods. Exemplary cases are presented step by step. Subjects: Diagnosis; Surgical materials; Description of the surgical procedure; Documentation of results; Practical hints; Bibliography; Current studies. (orig.)

  13. Massive cerebral arterial air embolism following arterial catheterization

    Energy Technology Data Exchange (ETDEWEB)

    Yang, C.W. [Northwestem University Feinberg School of Medicine, Department of Radiology, Chicago, IL (United States); Yang, B.P. [Northwestern University Feinberg School of Medicine, Department of Neurological Surgery, Chicago, IL (United States)

    2005-12-01

    Microscopic cerebral arterial air embolism (CAAE) has been described in many patients undergoing cardiac surgery as well as other invasive diagnostic and therapeutic procedures. However, massive CAAE is rare. We report a 42-year-old woman who initially presented with thalamic and basal ganglia hemorrhages. Shortly after a radial arterial catheter was inserted, the patient suffered a generalized seizure and CT demonstrated intra-arterial air in bilateral cerebral hemispheres. (orig.)

  14. EFFECTS OF PARENT ARTERY SEGMENTATION AND ANEURISMALWALL ELASTICITY ON PATIENT-SPECIFIC HEMODYNAMIC SIMULATIONS

    Institute of Scientific and Technical Information of China (English)

    CHEN Jia-liang; DING Guang-hong; YANG Xin-jian; LI Hai-yun

    2011-01-01

    It is well known that hemodynamics and wall tension play an important role in the formation,growth and rupture of aneurysms.In the present study,the authors investigated the influence of parent artery segmentation and aneurismal-wall elasticity on patient-specific hemodynamic simulations with two patient-specific eases of cerebral aneurysms.Realistic models of the aneurysms were constructed from 3-D angiography images and blood flow dynamics was studied under physiologically representative waveform of inflow.For each aneurysm three computational models were constructed:Model 1 with more extensive upstream parent artery with the rigid arterial and aneurismal wall,Model 2 with the partial upstream parent artery with the elastic arterial and aneurismal wall,Model 3 with more extensive upstream parent artery with the rigid wall for arterial wall far from the aneurysm and the elastic wall for arterial wall near the aneurysm.The results show that Model 1 could predict complex intra-aneurismal flow patterns and wall shear stress distribution in the aneurysm,but is unable to give aneurismal wall deformation and tension,Model 2 demonstrates aneurismal wall deformation and tension,but fails to properly model inflow pattern contributed by the upstream parent artery,resulting in local misunderstanding Wall Shear Stress (WSS) distribution,Model 3 can overcome limitations of the former two models,and give an overall and accurate analysis on intra-aneurismal flow patterns,wall shear stress distribution,aneurismal-wall deformation and tension.Therefore we suggest that the proper length of extensive upstream parent artery and aneuri-smal-wall elasticity should be considered carefully in establishing computational model to predict the intra-aneurismal hemodynamic and wall tension.

  15. MRI of the carotid artery at 7 Tesla: Quantitative comparison with 3 Tesla

    NARCIS (Netherlands)

    Koning, Wouter; De Rotte, Alexandra A J; Bluemink, Johanna J.; Van Der Velden, Tijl A.; Luijten, Peter R.; Klomp, DWJ; Zwanenburg, Jaco J M

    2015-01-01

    Purpose: To evaluate the 7 Tesla (T) MRI of the carotid arteries, as quantitatively compared with 3T. Materials and Methods: The 7T MRI of the carotid arteries was performed in six healthy subjects and in two patients with carotid stenosis. The healthy group was scanned at 3T and at 7T, using

  16. Feasibility of BCI Control in a Realistic Smart Home Environment

    Science.gov (United States)

    Kosmyna, Nataliya; Tarpin-Bernard, Franck; Bonnefond, Nicolas; Rivet, Bertrand

    2016-01-01

    Smart homes have been an active area of research, however despite considerable investment, they are not yet a reality for end-users. Moreover, there are still accessibility challenges for the elderly or the disabled, two of the main potential targets for home automation. In this exploratory study we design a control mechanism for smart homes based on Brain Computer Interfaces (BCI) and apply it in the “Domus”1 smart home platform in order to evaluate the potential interest of users about BCIs at home. We enable users to control lighting, a TV set, a coffee machine and the shutters of the smart home. We evaluate the performance (accuracy, interaction time), usability and feasibility (USE questionnaire) on 12 healthy subjects and 2 disabled subjects. We find that healthy subjects achieve 77% task accuracy. However, disabled subjects achieved a better accuracy (81% compared to 77%). PMID:27616986

  17. Feasibility of BCI Control in a Realistic Smart Home Environment

    Directory of Open Access Journals (Sweden)

    Nataliya Kosmyna

    2016-08-01

    Full Text Available Smart homes have been an active area of research, however despite considerable investment, they are not yet a reality for end-users. Moreover, there are still accessibility challenges for the elderly or the disabled, two of the main potential targets for home automation. In this exploratory study we design a control mechanism for smart homes based on Brain Computer Interfaces (BCI and apply it in the Domus smart home platform in order to evaluate the potential interest of users about BCIs at home. We enable users to control lighting, a TV set, a coffee machine and the shutters of the smart home. We evaluate the performance (accuracy, interaction time, usability and feasibility (USE questionnaire on 12 healthy subjects and 2 disabled subjects. We find that healthy subjects achieve 77% task accuracy. However, disabled subjects achieved a better accuracy (81% compared to 77%.

  18. Feasibility of BCI Control in a Realistic Smart Home Environment.

    Science.gov (United States)

    Kosmyna, Nataliya; Tarpin-Bernard, Franck; Bonnefond, Nicolas; Rivet, Bertrand

    2016-01-01

    Smart homes have been an active area of research, however despite considerable investment, they are not yet a reality for end-users. Moreover, there are still accessibility challenges for the elderly or the disabled, two of the main potential targets for home automation. In this exploratory study we design a control mechanism for smart homes based on Brain Computer Interfaces (BCI) and apply it in the "Domus" smart home platform in order to evaluate the potential interest of users about BCIs at home. We enable users to control lighting, a TV set, a coffee machine and the shutters of the smart home. We evaluate the performance (accuracy, interaction time), usability and feasibility (USE questionnaire) on 12 healthy subjects and 2 disabled subjects. We find that healthy subjects achieve 77% task accuracy. However, disabled subjects achieved a better accuracy (81% compared to 77%).

  19. Relationship of cerebral arterial stenosis to cognitive and memory disorders

    Institute of Scientific and Technical Information of China (English)

    Jifeng Li; Zhou Wang; Shenggang Sun; Gaomei Cai; Kejin Gu; Yaoqun Li

    2006-01-01

    BACKGROUND: Cerebral arterial stenosis can cause cerebral hypoperfusion, and than result in the decline of cognitive function, whereas the cognitive dysfunction induced by different cerebral arterial stenosis have different manifestations and types.OBJECTIVE: To observe the differences of cognitive and memory dysfunctions in patients with cerebral arterial stenosis of different types.DESIGN: A comparative observation.SETTING: Affiliated Hospital of Jining Medical College.PARTICIPANTS: Forty-two outpatients or inpatients with cerebral arterial stenosis were selected from the Department of Neurology, Affiliated Hospital of Jining Medical College from February 2005 to January 2006,including 25 males and 17 females. There were 18 cases of internal carotid arterial stenosis, 14 cases of vertebrobasilar arterial stenosis and 10 cases of whole cerebral arterial stenosis. The diagnostic standards for cerebral arterial stenosis were identified according to North American Symptomatic Carotid Endarterectomy Trial (NAS CET). Meanwhile, 18 healthy physical examinees were enrolled as the control group, including 10males and 8 females, aged 58-80 years old. All the enrolled subjects were informed and agreed with the detection and evaluation.METHODS: ① The memory function was evaluated using revised Wechsler memory scale for adults, including long-term memory (experience, orientation and counting), short-term memory (visual recognition, picture memory, visual regeneration, association and thigmesthesia) and sensory memory (forward and backward recitation of numbers). The scale scores were turned to memory quotients. The higher the scores, the better the memory function. ② The cognitive function was evaluated using revised Wechsler adult intelligence scale:It consisted of eleven subtests, including six language scales (information, digit span, vocabulary, arithmetics,apprehension, similarity) and five operation scales (picture completion, picture arrangement, block design

  20. Implementing enhanced recovery pathways: a literature review with realist synthesis.

    Science.gov (United States)

    Coxon, Astrid; Nielsen, Karina; Cross, Jane; Fox, Chris

    2017-10-01

    Enhanced Recovery Pathways (ERPs) are an increasingly popular, evidenced-based approach to surgery, designed to improve patient outcomes and reduce costs. Despite evidence demonstrating the benefits of these pathways, implementation and adherence have been inconsistent. Using realist synthesis, this review explored the current literature surrounding the implementation of ERPs in the UK. Knowledge consolidation between authors and consulting with field experts helped to guide the search strategy. Relevant medical and social science databases were searched from 2000 to 2016, as well as a general web search. A total of 17 papers were identified, including original research, reviews, case studies and guideline documents. Full texts were analysed, cross-examined, and data extracted and synthesised. Several implementation strategies were identified, including the contexts in which these operated, the subsequent mechanisms of action that were triggered, and the outcome patterns they produced. Context-Mechanism-Outcome (CMO) configurations were generated, tested, and refined. These were grouped to develop two programme theories concerning ERP implementation, one related to the strategy of consulting with staff, the other with appointing a change agent to coordinate and drive the implementation process. These theories highlight instances in which implementation could be improved. Current literature in ERP research is primarily focussed on measuring patient outcomes and cost effectiveness, and as a result, important detail regarding the implementation process is often not reported or described robustly. This review not only provides recommendations for future improvements in ERP implementation, but also highlights specific areas of focus for furthering ERP implementation research.

  1. A Data-Driven Approach to Realistic Shape Morphing

    KAUST Repository

    Gao, Lin; Lai, Yu-Kun; Huang, Qi-Xing; Hu, Shi-Min

    2013-01-01

    Morphing between 3D objects is a fundamental technique in computer graphics. Traditional methods of shape morphing focus on establishing meaningful correspondences and finding smooth interpolation between shapes. Such methods however only take geometric information as input and thus cannot in general avoid producing unnatural interpolation, in particular for large-scale deformations. This paper proposes a novel data-driven approach for shape morphing. Given a database with various models belonging to the same category, we treat them as data samples in the plausible deformation space. These models are then clustered to form local shape spaces of plausible deformations. We use a simple metric to reasonably represent the closeness between pairs of models. Given source and target models, the morphing problem is casted as a global optimization problem of finding a minimal distance path within the local shape spaces connecting these models. Under the guidance of intermediate models in the path, an extended as-rigid-as-possible interpolation is used to produce the final morphing. By exploiting the knowledge of plausible models, our approach produces realistic morphing for challenging cases as demonstrated by various examples in the paper. © 2013 The Eurographics Association and Blackwell Publishing Ltd.

  2. Bayesian inversion using a geologically realistic and discrete model space

    Science.gov (United States)

    Jaeggli, C.; Julien, S.; Renard, P.

    2017-12-01

    Since the early days of groundwater modeling, inverse methods play a crucial role. Many research and engineering groups aim to infer extensive knowledge of aquifer parameters from a sparse set of observations. Despite decades of dedicated research on this topic, there are still several major issues to be solved. In the hydrogeological framework, one is often confronted with underground structures that present very sharp contrasts of geophysical properties. In particular, subsoil structures such as karst conduits, channels, faults, or lenses, strongly influence groundwater flow and transport behavior of the underground. For this reason it can be essential to identify their location and shape very precisely. Unfortunately, when inverse methods are specially trained to consider such complex features, their computation effort often becomes unaffordably high. The following work is an attempt to solve this dilemma. We present a new method that is, in some sense, a compromise between the ergodicity of Markov chain Monte Carlo (McMC) methods and the efficient handling of data by the ensemble based Kalmann filters. The realistic and complex random fields are generated by a Multiple-Point Statistics (MPS) tool. Nonetheless, it is applicable with any conditional geostatistical simulation tool. Furthermore, the algorithm is independent of any parametrization what becomes most important when two parametric systems are equivalent (permeability and resistivity, speed and slowness, etc.). When compared to two existing McMC schemes, the computational effort was divided by a factor of 12.

  3. Convective aggregation in idealised models and realistic equatorial cases

    Science.gov (United States)

    Holloway, Chris

    2015-04-01

    Idealised explicit convection simulations of the Met Office Unified Model are shown to exhibit spontaneous self-aggregation in radiative-convective equilibrium, as seen previously in other models in several recent studies. This self-aggregation is linked to feedbacks between radiation, surface fluxes, and convection, and the organization is intimately related to the evolution of the column water vapour (CWV) field. To investigate the relevance of this behaviour to the real world, these idealized simulations are compared with five 15-day cases of real organized convection in the tropics, including multiple simulations of each case testing sensitivities of the convective organization and mean states to interactive radiation, interactive surface fluxes, and evaporation of rain. Despite similar large-scale forcing via lateral boundary conditions, systematic differences in mean CWV, CWV distribution shape, and the length scale of CWV features are found between the different sensitivity runs, showing that there are at least some similarities in sensitivities to these feedbacks in both idealized and realistic simulations.

  4. Nonstandard Farey sequences in a realistic diode map

    International Nuclear Information System (INIS)

    Perez, G.; Sinha, S.; Cerdeira, H.

    1991-06-01

    We study a realistic coupled map system, modelling a p - i - n diode structure. As we vary the parameter corresponding to the (scaled) external potential in the model, the dynamics goes through a flip bifurcation and then a Hopf bifurcation, and as the parameter is increased further, we find evidence of a sequence of mode locked windows embedded in the quasiperiodic motion, with periodic attractors whose winding numbers p = p/q, are given by a Farey series. The interesting thing about this Farey sequence is that it is generated between two parent attractors with p = 2/7 and 2/8, where 2/8 implies two distinct coexisting attractors with p = 1/4, and the correct series is obtained only when we use parent winding number 2/8 and not 1/4. So unlike a regular Farey tree, p and q need not be relatively prime here, p = 2 x p/2 x q is permissible, where such attractors are actually comprised of two coexisting attractors with p = p/q. We also checked that the positions and widths of these windows exhibit well defined power law scaling. When the potential is increased further, the Farey windows still provide a ''skeleton'' for the dynamics, and within each window there is a host of other interesting dynamical features, including multiple forward and reverse Feigenbaum trees. (author). 15 refs, 7 figs

  5. Modelisation of synchrotron radiation losses in realistic tokamak plasmas

    International Nuclear Information System (INIS)

    Albajar, F.; Johner, J.; Granata, G.

    2000-08-01

    Synchrotron radiation losses become significant in the power balance of high-temperature plasmas envisaged for next step tokamaks. Due to the complexity of the exact calculation, these losses are usually roughly estimated with expressions derived from a plasma description using simplifying assumptions on the geometry, radiation absorption, and density and temperature profiles. In the present article, the complete formulation of the transport of synchrotron radiation is performed for realistic conditions of toroidal plasma geometry with elongated cross-section, using an exact method for the calculation of the absorption coefficient, and for arbitrary shapes of density and temperature profiles. The effects of toroidicity and temperature profile on synchrotron radiation losses are analyzed in detail. In particular, when the electron temperature profile is almost flat in the plasma center, as for example in ITB confinement regimes, synchrotron losses are found to be much stronger than in the case where the profile is represented by its best generalized parabolic approximation, though both cases give approximately the same thermal energy contents. Such an effect is not included in present approximate expressions. Finally, we propose a seven-variable fit for the fast calculation of synchrotron radiation losses. This fit is derived from a large database, which has been generated using a code implementing the complete formulation and optimized for massively parallel computing. (author)

  6. From Delivery to Adoption of Physical Activity Guidelines: Realist Synthesis

    Directory of Open Access Journals (Sweden)

    Liliana Leone

    2017-10-01

    Full Text Available Background: Evidence-based guidelines published by health authorities for the promotion of health-enhancing physical activity (PA, continue to be implemented unsuccessfully and demonstrate a gap between evidence and policies. This review synthesizes evidence on factors influencing delivery, adoption and implementation of PA promotion guidelines within different policy sectors (e.g., health, transport, urban planning, sport, education. Methods: Published literature was initially searched using PubMed, EBSCO, Google Scholar and continued through an iterative snowball technique. The literature review spanned the period 2002–2017. The realist synthesis approach was adopted to review the content of 39 included studies. An initial programme theory with a four-step chain from evidence emersion to implementation of guidelines was tested. Results: The synthesis furthers our understanding of the link between PA guidelines delivery and the actions of professionals responsible for implementation within health services, school departments and municipalities. The main mechanisms identified for guidance implementation were scientific legitimation, enforcement, feasibility, familiarity with concepts and PA habits. Threats emerged to the successful implementation of PA guidelines at national/local jurisdictional levels. Conclusions: The way PA guidelines are developed may influence their adoption by policy-makers and professionals. Useful lessons emerged that may inform synergies between policymaking and professional practices, promoting win-win multisectoral strategies.

  7. Improved transcranial magnetic stimulation coil design with realistic head modeling

    Science.gov (United States)

    Crowther, Lawrence; Hadimani, Ravi; Jiles, David

    2013-03-01

    We are investigating Transcranial magnetic stimulation (TMS) as a noninvasive technique based on electromagnetic induction which causes stimulation of the neurons in the brain. TMS can be used as a pain-free alternative to conventional electroconvulsive therapy (ECT) which is still widely implemented for treatment of major depression. Development of improved TMS coils capable of stimulating subcortical regions could also allow TMS to replace invasive deep brain stimulation (DBS) which requires surgical implantation of electrodes in the brain. Our new designs allow new applications of the technique to be established for a variety of diagnostic and therapeutic applications of psychiatric disorders and neurological diseases. Calculation of the fields generated inside the head is vital for the use of this method for treatment. In prior work we have implemented a realistic head model, incorporating inhomogeneous tissue structures and electrical conductivities, allowing the site of neuronal activation to be accurately calculated. We will show how we utilize this model in the development of novel TMS coil designs to improve the depth of penetration and localization of stimulation produced by stimulator coils.

  8. Factors influencing intercultural doctor-patient communication: a realist review.

    Science.gov (United States)

    Paternotte, Emma; van Dulmen, Sandra; van der Lee, Nadine; Scherpbier, Albert J J A; Scheele, Fedde

    2015-04-01

    Due to migration, doctors see patients from different ethnic backgrounds. This causes challenges for the communication. To develop training programs for doctors in intercultural communication (ICC), it is important to know which barriers and facilitators determine the quality of ICC. This study aimed to provide an overview of the literature and to explore how ICC works. A systematic search was performed to find literature published before October 2012. The search terms used were cultural, communication, healthcare worker. A realist synthesis allowed us to use an explanatory focus to understand the interplay of communication. In total, 145 articles met the inclusion criteria. We found ICC challenges due to language, cultural and social differences, and doctors' assumptions. The mechanisms were described as factors influencing the process of ICC and divided into objectives, core skills and specific skills. The results were synthesized in a framework for the development of training. The quality of ICC is influenced by the context and by the mechanisms. These mechanisms translate into practical points for training, which seem to have similarities with patient-centered communication. Training for improving ICC can be developed as an extension of the existing training for patient-centered communication. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  9. Use of clinical guidelines in remote Australia: A realist evaluation.

    Science.gov (United States)

    Reddy, Sandeep; Orpin, Victoria; Herring, Sally; Mackie-Schneider, Stephanie; Struber, Janet

    2018-02-01

    The aim of this evaluation was to assess the acceptability, accessibility, and compliance with the 2014 editions of the Remote Primary Health Care Manuals (RPHCM) in health care centres across remote areas of Northern and Central Australia. To undertake a comprehensive evaluation that considered context, the evaluation used a realist evaluation framework. The evaluation used a variety of methods including interviews and survey to develop and test a programme theory. Many remote health practitioners have adopted standardized, evidence-based practice because of the use of the RPHCM. The mechanisms that led to the use of the manuals include acceptance of the worth of the protocols to their clinical practice, reliance on manual content to guide their practice, the perception of credibility, the applicability of RPHCM content to the context, and a fear of the consequences of not using the RPHCMs. Some remote health practitioners are less inclined to use the RPHCM regularly because of a perception that the content is less suited to their needs and daily practice or it is hard to navigate or understand. The evaluation concluded that there is work to be done to widen the RPHCM user base, and organizations need to increase support for their staff to use the RPHCM protocols better. These measures are expected to enable standardized clinical practice in the remote context. © 2017 John Wiley & Sons, Ltd.

  10. Atomistic simulations of graphite etching at realistic time scales.

    Science.gov (United States)

    Aussems, D U B; Bal, K M; Morgan, T W; van de Sanden, M C M; Neyts, E C

    2017-10-01

    Hydrogen-graphite interactions are relevant to a wide variety of applications, ranging from astrophysics to fusion devices and nano-electronics. In order to shed light on these interactions, atomistic simulation using Molecular Dynamics (MD) has been shown to be an invaluable tool. It suffers, however, from severe time-scale limitations. In this work we apply the recently developed Collective Variable-Driven Hyperdynamics (CVHD) method to hydrogen etching of graphite for varying inter-impact times up to a realistic value of 1 ms, which corresponds to a flux of ∼10 20 m -2 s -1 . The results show that the erosion yield, hydrogen surface coverage and species distribution are significantly affected by the time between impacts. This can be explained by the higher probability of C-C bond breaking due to the prolonged exposure to thermal stress and the subsequent transition from ion- to thermal-induced etching. This latter regime of thermal-induced etching - chemical erosion - is here accessed for the first time using atomistic simulations. In conclusion, this study demonstrates that accounting for long time-scales significantly affects ion bombardment simulations and should not be neglected in a wide range of conditions, in contrast to what is typically assumed.

  11. The construction of ``realistic'' four-dimensional strings through orbifolds

    Science.gov (United States)

    Font, A.; Ibáñez, L. E.; Quevedo, F.; Sierra, A.

    1990-02-01

    We discuss the construction of "realistic" lower rank 4-dimensional strings, through symmetric orbifolds with background fields. We present Z 3 three-generation SU(3) × SU(2) × U(1) models as well as models incorporating a left-right SU(2) L × SU(2) R × U(1) B-L symmetry in which proton stability is automatically guaranteed. Conformal field theory selection rules are used to find the flat directions to all orders which lead to these low-rank models and to study the relevant Yukawa couplings. A hierarchical structure of quark-lepton masses appears naturally in some models. We also present a detailed study of the structure of the Z 3 × Z 3 orbifold including the generalized GSO projection, the effect of discrete torsion and the conformal field theory Yukawa coupling selection rules. All these points are illustrated with a three-generation Z 3 × Z 3 model. We have made an effort to write a self-contained presentation in order to make this material available to non-string experts interested in the phenomenological aspects of this theory.

  12. The construction of 'realistic' four-dimensional strings through orbifolds

    International Nuclear Information System (INIS)

    Font, A.; Quevedo, F.; Sierra, A.

    1990-01-01

    We discuss the construction of 'realistic' lower rank 4-dimensional strings, through symmetric orbifolds with background fields. We present Z 3 three-generation SU(3)xSU(2)xU(1) models as well as models incorporating a left-right SU(2) L xSU(2) R xU(1) B-L symmetry in which proton stability is automatically guaranteed. Conformal field theory selection rules are used to find the flat directions to all orders which lead to these low-rank models and to study the relevant Yukawa couplings. A hierarchical structure of quark-lepton masses appears naturally in some models. We also present a detailed study of the structure of the Z 3 xZ 3 orbifold including the generalized GSO projection, the effect of discrete torsion and the conformal field theory Yukawa coupling selection rules. All these points are illustrated with a three-generation Z 3 xZ 3 model. We have made an effort to write a self-contained presentation in order to make this material available to non-string experts interested in the phenomenological aspects of this theory. (orig.)

  13. Management of long term sickness absence: a systematic realist review.

    Science.gov (United States)

    Higgins, Angela; O'Halloran, Peter; Porter, Sam

    2012-09-01

    The increasing impact and costs of long term sickness absence have been well documented. However, the diversity and complexity of interventions and of the contexts in which these take place makes a traditional review problematic. Therefore, we undertook a systematic realist review to identify the dominant programme theories underlying best practice, to assess the evidence for these theories, and to throw light on important enabling or disabling contextual factors. A search of the scholarly literature from 1950 to 2011 identified 5,576 articles, of which 269 formed the basis of the review. We found that the dominant programme theories in relation to effective management related to: early intervention or referral by employers; having proactive organisational procedures; good communication and cooperation between stakeholders; and workplace-based occupational rehabilitation. Significant contextual factors were identified as the level of support for interventions from top management, the size and structure of the organisation, the level of financial and organisational investment in the management of long-term sickness absence, and the quality of relationships between managers and staff. Consequently, those with responsibility for managing absence should bear in mind the contextual factors that are likely to have an impact on interventions, and do what they can to ensure stakeholders have at least a mutual understanding (if not a common purpose) in relation to their perceptions of interventions, goals, culture and practice in the management of long term sickness absence.

  14. Nucleon decay in a realistic SO(10) SUSY GUT

    International Nuclear Information System (INIS)

    Lucas, V.; Raby, S.

    1997-01-01

    In this paper, we calculate neutron and proton decay rates and branching ratios in a predictive SO(10) SUSY GUT which agrees well with low energy data. We show that the nucleon lifetimes are consistent with the experimental bounds. The nucleon decay rates are calculated using all one-loop chargino and gluino-dressed diagrams regardless of their chiral structure. We show that the four-fermion operator C jk (u R d jR )(d kL ν τL ), commonly neglected in previous nucleon decay calculations, not only contributes significantly to nucleon decay, but, for many values of the initial GUT parameters and for large tanβ, actually dominates the decay rate. As a consequence, we find that τ p /τ n is often substantially larger than the prediction obtained in small tanβ models. We also find that gluino-dressed diagrams, often neglected in nucleon decay calculations, contribute significantly to nucleon decay. In addition we find that the branching ratios obtained from this realistic SO(10) SUSY GUT differ significantly from the predictions obtained from open-quotes genericclose quotes SU(5) SUSY GUT close-quote s. Thus, nucleon decay branching ratios, when observed, can be used to test theories of fermion masses. copyright 1997 The American Physical Society

  15. A Realistic Seizure Prediction Study Based on Multiclass SVM.

    Science.gov (United States)

    Direito, Bruno; Teixeira, César A; Sales, Francisco; Castelo-Branco, Miguel; Dourado, António

    2017-05-01

    A patient-specific algorithm, for epileptic seizure prediction, based on multiclass support-vector machines (SVM) and using multi-channel high-dimensional feature sets, is presented. The feature sets, combined with multiclass classification and post-processing schemes aim at the generation of alarms and reduced influence of false positives. This study considers 216 patients from the European Epilepsy Database, and includes 185 patients with scalp EEG recordings and 31 with intracranial data. The strategy was tested over a total of 16,729.80[Formula: see text]h of inter-ictal data, including 1206 seizures. We found an overall sensitivity of 38.47% and a false positive rate per hour of 0.20. The performance of the method achieved statistical significance in 24 patients (11% of the patients). Despite the encouraging results previously reported in specific datasets, the prospective demonstration on long-term EEG recording has been limited. Our study presents a prospective analysis of a large heterogeneous, multicentric dataset. The statistical framework based on conservative assumptions, reflects a realistic approach compared to constrained datasets, and/or in-sample evaluations. The improvement of these results, with the definition of an appropriate set of features able to improve the distinction between the pre-ictal and nonpre-ictal states, hence minimizing the effect of confounding variables, remains a key aspect.

  16. Uncovering gender discrimination cues in a realistic setting.

    Science.gov (United States)

    Dupuis-Roy, Nicolas; Fortin, Isabelle; Fiset, Daniel; Gosselin, Frédéric

    2009-02-10

    Which face cues do we use for gender discrimination? Few studies have tried to answer this question and the few that have tried typically used only a small set of grayscale stimuli, often distorted and presented a large number of times. Here, we reassessed the importance of facial cues for gender discrimination in a more realistic setting. We applied Bubbles-a technique that minimizes bias toward specific facial features and does not necessitate the distortion of stimuli-to a set of 300 color photographs of Caucasian faces, each presented only once to 30 participants. Results show that the region of the eyes and the eyebrows-probably in the light-dark channel-is the most important facial cue for accurate gender discrimination; and that the mouth region is driving fast correct responses (but not fast incorrect responses)-the gender discrimination information in the mouth region is concentrated in the red-green color channel. Together, these results suggest that, when color is informative in the mouth region, humans use it and respond rapidly; and, when it's not informative, they have to rely on the more robust but more sluggish luminance information in the eye-eyebrow region.

  17. Linear perspective limitations on virtual reality and realistic displays

    Science.gov (United States)

    Temme, Leonard A.

    2007-04-01

    The visual images of the natural world, with their immediate intuitive appeal, seem like the logical gold standard for evaluating displays. After all, since photorealistic displays look so increasingly like the real world, what could be better? Part of the shortcoming of this intuitive appeal for displays is its naivete. Realism itself is full of potential illusions that we do not notice because, most of the time, realism is good enough for our everyday tasks. But when confronted with tasks that go beyond those for which our visual system has evolved, we may be blindsided. If we survive, blind to our erroneous perceptions and oblivious to our good fortune at having survived, we will not be any wiser next time. Realist displays depend on linear perspective (LP), the mathematical mapping of three dimensions onto two. Despite the fact that LP is a seductively elegant system that predicts results with defined mathematical procedures, artists do not stick to the procedures, not because they are math-phobic but because LP procedures, if followed explicitly, produce ugly, limited, and distorted images. If artists bother with formal LP procedures at all, they invariably temper the renderings by eye. The present paper discusses LP assumptions, limitations, and distortions. It provides examples of kluges to cover some of these LP shortcomings. It is important to consider the limitations of LP so that we do not let either naive assumptions or the seductive power of LP guide our thinking or expectations unrealistically as we consider its possible uses in advanced visual displays.

  18. Urban renewal, gentrification and health equity: a realist perspective.

    Science.gov (United States)

    Mehdipanah, Roshanak; Marra, Giulia; Melis, Giulia; Gelormino, Elena

    2018-04-01

    Up to now, research has focused on the effects of urban renewal programs and their impacts on health. While some of this research points to potential negative health effects due to gentrification, evidence that addresses the complexity associated with this relation is much needed. This paper seeks to better understand when, why and how health inequities arise from urban renewal interventions resulting in gentrification. A realist review, a qualitative systematic review method, aimed to better explain the relation between context, mechanism and outcomes, was used. A literature search was done to identify theoretical models of how urban renewal programs can result in gentrification, which in turn could have negative impacts on health. A systematic approach was then used to identify peer-reviewed studies that provided evidence to support or refute the initial assumptions. Urban renewal programs that resulted in gentrification tended to have negative health effects primarily in residents that were low-income. Urban renewal policies that were inclusive of populations that are vulnerable, from the beginning were less likely to result in gentrification and more likely to positively impact health through physical and social improvements. Research has shown urban renewal policies have significant impacts on populations that are vulnerable and those that result in gentrification can result in negative health consequences for this population. A better understanding of this is needed to impact future policies and advocate for a community-participatory model that includes such populations in the early planning stages.

  19. Towards realistic string vacua from branes at singularities

    Science.gov (United States)

    Conlon, Joseph P.; Maharana, Anshuman; Quevedo, Fernando

    2009-05-01

    We report on progress towards constructing string models incorporating both realistic D-brane matter content and moduli stabilisation with dynamical low-scale supersymmetry breaking. The general framework is that of local D-brane models embedded into the LARGE volume approach to moduli stabilisation. We review quiver theories on del Pezzo n (dPn) singularities including both D3 and D7 branes. We provide supersymmetric examples with three quark/lepton families and the gauge symmetries of the Standard, Left-Right Symmetric, Pati-Salam and Trinification models, without unwanted chiral exotics. We describe how the singularity structure leads to family symmetries governing the Yukawa couplings which may give mass hierarchies among the different generations. We outline how these models can be embedded into compact Calabi-Yau compactifications with LARGE volume moduli stabilisation, and state the minimal conditions for this to be possible. We study the general structure of soft supersymmetry breaking. At the singularity all leading order contributions to the soft terms (both gravity- and anomaly-mediation) vanish. We enumerate subleading contributions and estimate their magnitude. We also describe model-independent physical implications of this scenario. These include the masses of anomalous and non-anomalous U(1)'s and the generic existence of a new hyperweak force under which leptons and/or quarks could be charged. We propose that such a gauge boson could be responsible for the ghost muon anomaly recently found at the Tevatron's CDF detector.

  20. A Data-Driven Approach to Realistic Shape Morphing

    KAUST Repository

    Gao, Lin

    2013-05-01

    Morphing between 3D objects is a fundamental technique in computer graphics. Traditional methods of shape morphing focus on establishing meaningful correspondences and finding smooth interpolation between shapes. Such methods however only take geometric information as input and thus cannot in general avoid producing unnatural interpolation, in particular for large-scale deformations. This paper proposes a novel data-driven approach for shape morphing. Given a database with various models belonging to the same category, we treat them as data samples in the plausible deformation space. These models are then clustered to form local shape spaces of plausible deformations. We use a simple metric to reasonably represent the closeness between pairs of models. Given source and target models, the morphing problem is casted as a global optimization problem of finding a minimal distance path within the local shape spaces connecting these models. Under the guidance of intermediate models in the path, an extended as-rigid-as-possible interpolation is used to produce the final morphing. By exploiting the knowledge of plausible models, our approach produces realistic morphing for challenging cases as demonstrated by various examples in the paper. © 2013 The Eurographics Association and Blackwell Publishing Ltd.

  1. A realistic 3+1D Viscous Hydro Algorithm

    Energy Technology Data Exchange (ETDEWEB)

    Romatschke, Paul [Univ. of Colorado, Boulder, CO (United States)

    2015-05-31

    DoE funds were used as bridge funds for the faculty position for the PI at the University of Colorado. The total funds for the Years 3-5 of the JET Topical Collaboration amounted to about 50 percent of the academic year salary of the PI.The PI contributed to the JET Topical Collaboration by developing, testing and applying algorithms for a realistic simulation of the bulk medium created in relativistic ion collisions.Specifically, two approaches were studied, one based on a new Lattice-Boltzmann (LB) framework, and one on a more traditional viscous hydro-dynamics framework. Both approaches were found to be viable in principle, with the LB approach being more elegant but needing still more time to develop.The traditional approach led to the super-hybrid model of ion collisions dubbed 'superSONIC', and has been successfully used for phenomenology of relativistic heavy-ion and light-on-heavy-ion collisions.In the time-frame of the JET Topical Collaboration, the Colorado group has published 15 articles in peer-reviewed journals, three of which were published in Physical Review Letters. The group graduated one Master student during this time-frame and two more PhD students are expected to graduate in the next few years. The PI has given more than 28 talks and presentations during this period.

  2. Compiling quantum circuits to realistic hardware architectures using temporal planners

    Science.gov (United States)

    Venturelli, Davide; Do, Minh; Rieffel, Eleanor; Frank, Jeremy

    2018-04-01

    To run quantum algorithms on emerging gate-model quantum hardware, quantum circuits must be compiled to take into account constraints on the hardware. For near-term hardware, with only limited means to mitigate decoherence, it is critical to minimize the duration of the circuit. We investigate the application of temporal planners to the problem of compiling quantum circuits to newly emerging quantum hardware. While our approach is general, we focus on compiling to superconducting hardware architectures with nearest neighbor constraints. Our initial experiments focus on compiling Quantum Alternating Operator Ansatz (QAOA) circuits whose high number of commuting gates allow great flexibility in the order in which the gates can be applied. That freedom makes it more challenging to find optimal compilations but also means there is a greater potential win from more optimized compilation than for less flexible circuits. We map this quantum circuit compilation problem to a temporal planning problem, and generated a test suite of compilation problems for QAOA circuits of various sizes to a realistic hardware architecture. We report compilation results from several state-of-the-art temporal planners on this test set. This early empirical evaluation demonstrates that temporal planning is a viable approach to quantum circuit compilation.

  3. OFDM versus Single Carrier: A Realistic Multi-Antenna Comparison

    Directory of Open Access Journals (Sweden)

    Moonen Marc

    2004-01-01

    Full Text Available There is an ongoing discussion in the broadband wireless world about the respective benefits of orthogonal frequency division multiplexing (OFDM and single carrier with frequency domain equalization (SC-FD. SC-FD allows for more relaxed front-end requirements, of which the power amplifier efficiency is very important for battery-driven terminals. OFDM, on the other hand, can yield improved BER performance at low complexity. Both schemes have extensions to multiple antennas to enhance the spectral efficiency and/or the link reliability. Moreover, both schemes have nonlinear versions using decision feedback equalization (DFE to further improve performance of the linear equalizers. In this paper, we compare these high-performance OFDM and SC-FD schemes using multiple antennas and DFE, while also accounting for the power amplifier efficiency. To make a realistic comparison, we also consider most important digital imperfections, such as channel and noise estimation, transmit and receive filtering, clipping and quantization, as well as link layer impact. Our analysis shows that for frequency-selective channels the relative performance impact of the power amplifier is negligible compared to the frequency diversity impact. The higher frequency diversity exploitation of SC-FD allows it to outperform OFDM in most cases. Therefore, SC-FD is a suitable candidate for broadband wireless communication.

  4. Arterial responses during migraine headache

    DEFF Research Database (Denmark)

    Iversen, Helle Klingenberg; Nielsen, T H; Olesen, J

    1990-01-01

    The superficial temporal artery has been thought to be the main focus of pain during migraine attacks, but its diameter has never been measured directly. The use of a new, high-resolution ultrasound machine to measure arterial size in 25 migraine patients with unilateral head pain showed...... that the lumen was wider on the painful than on the non-painful side during a migraine attack. The diameters of both radial arteries and the temporal artery on the non-painful side were smaller during than between attacks. The generalised vasoconstriction was not shared by the temporal artery on the affected...... side, which suggests a local vasodilatory response. The findings suggest that cephalic arteries may play a role in migraine pathogenesis....

  5. Pulmonary Arterial Hypertension and Neonatal Arterial Switch Surgery for Correction of Transposition of the Great Arteries.

    Science.gov (United States)

    Domínguez Manzano, Paula; Mendoza Soto, Alberto; Román Barba, Violeta; Moreno Galdó, Antonio; Galindo Izquierdo, Alberto

    2016-09-01

    There are few reports of the appearance of pulmonary arterial hypertension following arterial switch surgery in the neonatal period to correct transposition of the great arteries. We assessed the frequency and clinical pattern of this complication in our series of patients. Our database was reviewed to select patients with transposition of the great arteries corrected by neonatal arterial switch at our hospital and who developed pulmonary hypertension over time. We identified 2 (1.3%) patients with transposition of the great arteries successfully repaired in the first week of life who later experienced pulmonary arterial hypertension. The first patient was a 7-year-old girl diagnosed with severe pulmonary hypertension at age 8 months who did not respond to medical treatment and required lung transplantation. The anatomic pathology findings were consistent with severe pulmonary arterial hypertension. The second patient was a 24-month-old boy diagnosed with severe pulmonary hypertension at age 13 months who did not respond to medical therapy. Pulmonary hypertension is a rare but very severe complication that should be investigated in all patients with transposition of the great arteries who have undergone neonatal arterial switch, in order to start early aggressive therapy for affected patients, given the poor therapeutic response and poor prognosis involved. Copyright © 2016 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.

  6. Roentgenologic anatomy of dog arteries

    International Nuclear Information System (INIS)

    Rehak, J.; Hlava, A.; Bavor, J.

    1984-01-01

    In catheter methods in dogs the knowledge of the roentgenologic anatomy of blood vessels is very important. Because of lacking in such roentgenologic anatomic schemes 5 arterial schemes in relation to the skeleton were elaborated. The system of arteries was divided into five regions: chest, head and neck in submentooccipital and lateral projection, abdomen and pelvis. The schemes comprise 75 of the main arteries of the dog. (author)

  7. Arterial mapping of lower limbs

    International Nuclear Information System (INIS)

    Acuna Allen, Rafael

    2011-01-01

    A bibliographic review is realized in the arterial mapping of lower limbs by ultrasonographic. The physical properties of the Doppler effect applied to diagnostic ultrasound are described. The anatomical characteristics of the general arterial system and specifically of the lower limbs arterial system are mentioned. Pathologies of the ischemic arterial disease of lower limbs are explained. The study characteristics of lower limbs arterial mapping are documented to determine its importance as appropriate method for the assessment of lower limb ischemia. An adequate arterial mapping of lower limbs is recognized in atherosclerotic ischemic disease as a reliable initial method alternative to arteriography. Arteriography is considered as reference pattern for therapeutic decision making in patients with critical ischemia of the lower limbs. Non-invasive methods to assess the arterial system of lower limbs has evidenced the advantages of the arterial mapping with Doppler, according to the consulted literature. The combination morphological and hemodynamic information has been possible and a map of the explored zone is made. The arterial mapping by ultrasonography has offered similar reliability to angiography [es

  8. Sensibility and Subjectivity: Levinas’ Traumatic Subject

    Directory of Open Access Journals (Sweden)

    Rashmika Pandya

    2011-02-01

    Full Text Available The importance of Levinas’ notions of sensibility and subjectivity are evident in the revision of phenomenological method by current phenomenologists such as Jean-Luc Marion and Michel Henry. The criticisms of key tenants of classical phenomenology, intentionality and reduction, are of a particular note. However, there are problems with Levinas’ characterization of subjectivity as essentially sensible. In “Totality and Infinity” and “Otherwise than Being”, Levinas criticizes and recasts a traditional notion of subjectivity, particularly the notion of the subject as the first and foremost rational subject. The subject in Levinas’ works is characterized more by its sensibility and affectedness than by its capacity to reason or affect its world. Levinas ties rationality to economy and suggests an alternative notion of reason that leads to his analysis of the ethical relation as the face-to-face encounter. The ‘origin’ of the social relation is located not in our capacity to know but rather in a sensibility that is diametrically opposed to the reason understood as economy. I argue that the opposition in Levinas’ thought between reason and sensibility is problematic and essentially leads to a self-conflicted subject. In fact, it would seem that violence characterizes the subject’s self-relation and, thus, is also inscribed at the base of the social relation. Rather than overcoming a problematic tendency to dualistic thought in philosophy Levinas merely reverses traditional hierarchies of reason/emotion, subject/object and self/other. 

  9. Masculine complex: From realistic discrimination to unconscious implementation

    Directory of Open Access Journals (Sweden)

    Todorović Milorad V.

    2013-01-01

    Full Text Available Critics that is coming from women and women's movements, marred in large part by psychoanalysis, structuralism, semiology and deconstructionism, have made significant inroads in the dispossession of strong subject, not only for their own benefit but also for the benefit of that same powerless strong subject. Rejecting the imposition of a false universalism of one single (male culture, women's studies have made the necessary re-interpretation of history in which women were excluded. Excluded women, woman commodity, woman sign that enables male communication, had the means to reduce the power of strong subject and destroy her and his sexuality. This was mainly contributed by inevitable unconscious position of excluded, slave, commodity or poor subject as complex of masculinity. It's not only about the fact that power is in the one that is object of envy. Through complex of masculinity and rejection of women, woman is trying to ' be '. Women , in the words of Judith Butler ( Butler , can never just ' be ', because they are the measure of the difference. Women are the 'difference' that can not be seen as a 'second ', or, they are merely the negation of the subject that can only be male ( Butler 2010:77 . For mental development it is of paramount importance in which way will complex of masculinity affect the sexuality as a central place of 'psychic'. It is a question of most importance for civilization.

  10. Right hepatic artery aneurysm.

    Science.gov (United States)

    Bernal, Astrid Del Pilar Ardila; Loures, Paulo; Calle, Juan Cristóbal Ospina; Cunha, Beatriz; Córdoba, Juan Camilo

    2016-01-01

    We report a case of an aneurysm of the right hepatic artery and its multidisciplinary management by general surgery, endoscopy and radiology services. Being a case of extremely low incidence, it is important to show its diagnostic and therapeutic approach. RESUMO Relatamos um caso de aneurisma da artéria hepática direita conduzido de forma multidisciplinar pelos Serviços de Cirurgia Geral, Endoscopia e Radiologia. Em se tratando de caso de incidência baixíssima, é importante mostrar o enfoque diagnóstico e terapêutico usado em seu manejo.

  11. Arterial hypoxaemia in cirrhosis

    DEFF Research Database (Denmark)

    Møller, S; Hillingsø, Jens; Christensen, E

    1998-01-01

    characteristics. PATIENTS: One hundred and forty two patients with cirrhosis without significant hepatic encephalopathy (grades 0-I) (41 patients in Child class A, 57 in class B, and 44 in class C) and 21 patients with hepatic encephalopathy. RESULTS: Mean Po2 in kPa was 11.3 in Child class A, 10.8 in class B, 10...... resistance, and a low indocyanine green clearance (p hepatic dysfunction. Arterial hypoxaemia in patients with cirrhosis of differing.......6 in class C, and 10.6 in patients with encephalopathy (p C, and in patients with encephalopathy (p

  12. Development of optoelectronic monitoring system for ear arterial pressure waveforms

    Science.gov (United States)

    Sasayama, Satoshi; Imachi, Yu; Yagi, Tamotsu; Imachi, Kou; Ono, Toshirou; Man-i, Masando

    1994-02-01

    Invasive intra-arterial blood pressure measurement is the most accurate method but not practical if the subject is in motion. The apparatus developed by Wesseling et al., based on a volume-clamp method of Penaz (Finapres), is able to monitor continuous finger arterial pressure waveforms noninvasively. The limitation of Finapres is the difficulty in measuring the pressure of a subject during work that involves finger or arm action. Because the Finapres detector is attached to subject's finger, the measurements are affected by inertia of blood and hydrostatic effect cause by arm or finger motion. To overcome this problem, the authors made a detector that is attached to subject's ear and developed and optoelectronic monitoring systems for ear arterial pressure waveform (Earpres). An IR LEDs, photodiode, and air cuff comprised the detector. The detector was attached to a subject's ear, and the space adjusted between the air cuff and the rubber plate on which the LED and photodiode were positioned. To evaluate the accuracy of Earpres, the following tests were conducted with participation of 10 healthy male volunteers. The subjects rested for about five minutes, then performed standing and squatting exercises to provide wide ranges of systolic and diastolic arterial pressure. Intra- and inter-individual standard errors were calculated according to the method of van Egmond et al. As a result, average, the averages of intra-individual standard errors for earpres appeared small (3.7 and 2.7 mmHg for systolic and diastolic pressure respectively). The inter-individual standard errors for Earpres were about the same was Finapres for both systolic and diastolic pressure. The results showed the ear monitor was reliable in measuring arterial blood pressure waveforms and might be applicable to various fields such as sports medicine and ergonomics.

  13. Development of Realistic Safety Analysis Technology for CANDU Reactors

    International Nuclear Information System (INIS)

    Park, Joo Hwan; Rhee, B. W.; Rho, G. H.

    2010-04-01

    The following 3 research items have been studied to develop and establish the realistic safety analysis and the associated technologies for a CANDU reactor. At the first, WIMS-CANDU which is physics cell code for a CANDU has been improved and validated against the physics criticality experiment data transferred through the international cooperation programs. Also an improved physics model to take into account the pressure tube creep was developed and utilized to assess the effects of the pressure tube creep of 0%, 2.5% and 5% diametral increase of pressure tube on core physics parameters. Secondly, the interfacing module between physics and thermal-hydraulics codes has been developed to provide the enhancement of reliability and convenience of the calculation results of the physics parameters such as power coefficient which was calculated by independent code systems. Finally, the important parameters related to the complex heat transfer mechanisms in the crept pressure tubes were identified to find how to improve the existing fuel channel models. One of the important parameters such as the oxidation model of Zr-steam reaction was identified, implemented and verified with the experimental data of the high pressure and temperature fuel channel and its model was utilized for CFD analysis of the crept pressure tube effect on the reactor safety. The results were also provided to validate the CATNENA models of the crept pressure tube and the effects of the pressure tube creep on the blowdown and post-blowdown phase during LOCA was assessed. The results of this study can be used to assess the uncertainty analysis of coolant void reactivity and the effects of the creep deformed pressure tubes on physics/TH/safety issues. Also, those results will be used to improve the current design and operational safety analysis codes, and to technically support the related issues to resolve their problems

  14. Magnetic resonance fingerprinting based on realistic vasculature in mice.

    Science.gov (United States)

    Pouliot, Philippe; Gagnon, Louis; Lam, Tina; Avti, Pramod K; Bowen, Chris; Desjardins, Michèle; Kakkar, Ashok K; Thorin, Eric; Sakadzic, Sava; Boas, David A; Lesage, Frédéric

    2017-04-01

    Magnetic resonance fingerprinting (MRF) was recently proposed as a novel strategy for MR data acquisition and analysis. A variant of MRF called vascular MRF (vMRF) followed, that extracted maps of three parameters of physiological importance: cerebral oxygen saturation (SatO 2 ), mean vessel radius and cerebral blood volume (CBV). However, this estimation was based on idealized 2-dimensional simulations of vascular networks using random cylinders and the empirical Bloch equations convolved with a diffusion kernel. Here we focus on studying the vascular MR fingerprint using real mouse angiograms and physiological values as the substrate for the MR simulations. The MR signal is calculated ab initio with a Monte Carlo approximation, by tracking the accumulated phase from a large number of protons diffusing within the angiogram. We first study the identifiability of parameters in simulations, showing that parameters are fully estimable at realistically high signal-to-noise ratios (SNR) when the same angiogram is used for dictionary generation and parameter estimation, but that large biases in the estimates persist when the angiograms are different. Despite these biases, simulations show that differences in parameters remain estimable. We then applied this methodology to data acquired using the GESFIDE sequence with SPIONs injected into 9 young wild type and 9 old atherosclerotic mice. Both the pre injection signal and the ratio of post-to-pre injection signals were modeled, using 5-dimensional dictionaries. The vMRF methodology extracted significant differences in SatO 2 , mean vessel radius and CBV between the two groups, consistent across brain regions and dictionaries. Further validation work is essential before vMRF can gain wider application. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. Biochemical transport modeling, estimation, and detection in realistic environments

    Science.gov (United States)

    Ortner, Mathias; Nehorai, Arye

    2006-05-01

    Early detection and estimation of the spread of a biochemical contaminant are major issues for homeland security applications. We present an integrated approach combining the measurements given by an array of biochemical sensors with a physical model of the dispersion and statistical analysis to solve these problems and provide system performance measures. We approximate the dispersion model of the contaminant in a realistic environment through numerical simulations of reflected stochastic diffusions describing the microscopic transport phenomena due to wind and chemical diffusion using the Feynman-Kac formula. We consider arbitrary complex geometries and account for wind turbulence. Localizing the dispersive sources is useful for decontamination purposes and estimation of the cloud evolution. To solve the associated inverse problem, we propose a Bayesian framework based on a random field that is particularly powerful for localizing multiple sources with small amounts of measurements. We also develop a sequential detector using the numerical transport model we propose. Sequential detection allows on-line analysis and detecting wether a change has occurred. We first focus on the formulation of a suitable sequential detector that overcomes the presence of unknown parameters (e.g. release time, intensity and location). We compute a bound on the expected delay before false detection in order to decide the threshold of the test. For a fixed false-alarm rate, we obtain the detection probability of a substance release as a function of its location and initial concentration. Numerical examples are presented for two real-world scenarios: an urban area and an indoor ventilation duct.

  16. Coil optimisation for transcranial magnetic stimulation in realistic head geometry.

    Science.gov (United States)

    Koponen, Lari M; Nieminen, Jaakko O; Mutanen, Tuomas P; Stenroos, Matti; Ilmoniemi, Risto J

    Transcranial magnetic stimulation (TMS) allows focal, non-invasive stimulation of the cortex. A TMS pulse is inherently weakly coupled to the cortex; thus, magnetic stimulation requires both high current and high voltage to reach sufficient intensity. These requirements limit, for example, the maximum repetition rate and the maximum number of consecutive pulses with the same coil due to the rise of its temperature. To develop methods to optimise, design, and manufacture energy-efficient TMS coils in realistic head geometry with an arbitrary overall coil shape. We derive a semi-analytical integration scheme for computing the magnetic field energy of an arbitrary surface current distribution, compute the electric field induced by this distribution with a boundary element method, and optimise a TMS coil for focal stimulation. Additionally, we introduce a method for manufacturing such a coil by using Litz wire and a coil former machined from polyvinyl chloride. We designed, manufactured, and validated an optimised TMS coil and applied it to brain stimulation. Our simulations indicate that this coil requires less than half the power of a commercial figure-of-eight coil, with a 41% reduction due to the optimised winding geometry and a partial contribution due to our thinner coil former and reduced conductor height. With the optimised coil, the resting motor threshold of abductor pollicis brevis was reached with the capacitor voltage below 600 V and peak current below 3000 A. The described method allows designing practical TMS coils that have considerably higher efficiency than conventional figure-of-eight coils. Copyright © 2017 Elsevier Inc. All rights reserved.

  17. Realistic camera noise modeling with application to improved HDR synthesis

    Science.gov (United States)

    Goossens, Bart; Luong, Hiêp; Aelterman, Jan; Pižurica, Aleksandra; Philips, Wilfried

    2012-12-01

    Due to the ongoing miniaturization of digital camera sensors and the steady increase of the "number of megapixels", individual sensor elements of the camera become more sensitive to noise, even deteriorating the final image quality. To go around this problem, sophisticated processing algorithms in the devices, can help to maximally exploit the knowledge on the sensor characteristics (e.g., in terms of noise), and offer a better image reconstruction. Although a lot of research focuses on rather simplistic noise models, such as stationary additive white Gaussian noise, only limited attention has gone to more realistic digital camera noise models. In this article, we first present a digital camera noise model that takes several processing steps in the camera into account, such as sensor signal amplification, clipping, post-processing,.. We then apply this noise model to the reconstruction problem of high dynamic range (HDR) images from a small set of low dynamic range (LDR) exposures of a static scene. In literature, HDR reconstruction is mostly performed by computing a weighted average, in which the weights are directly related to the observer pixel intensities of the LDR image. In this work, we derive a Bayesian probabilistic formulation of a weighting function that is near-optimal in the MSE sense (or SNR sense) of the reconstructed HDR image, by assuming exponentially distributed irradiance values. We define the weighting function as the probability that the observed pixel intensity is approximately unbiased. The weighting function can be directly computed based on the noise model parameters, which gives rise to different symmetric and asymmetric shapes when electronic noise or photon noise is dominant. We also explain how to deal with the case that some of the noise model parameters are unknown and explain how the camera response function can be estimated using the presented noise model. Finally, experimental results are provided to support our findings.

  18. Achieving successful community engagement: a rapid realist review.

    Science.gov (United States)

    De Weger, E; Van Vooren, N; Luijkx, K G; Baan, C A; Drewes, H W

    2018-04-13

    Community engagement is increasingly seen as crucial to achieving high quality, efficient and collaborative care. However, organisations are still searching for the best and most effective ways to engage citizens in the shaping of health and care services. This review highlights the barriers and enablers for engaging communities in the planning, designing, governing, and/or delivering of health and care services on the macro or meso level. It provides policymakers and professionals with evidence-based guiding principles to implement their own effective community engagement (CE) strategies. A Rapid Realist Review was conducted to investigate how interventions interact with contexts and mechanisms to influence the effectiveness of CE. A local reference panel, consisting of health and care professionals and experts, assisted in the development of the research questions and search strategy. The panel's input helped to refine the review's findings. A systematic search of the peer-reviewed literature was conducted. Eight action-oriented guiding principles were identified: Ensure staff provide supportive and facilitative leadership to citizens based on transparency; foster a safe and trusting environment enabling citizens to provide input; ensure citizens' early involvement; share decision-making and governance control with citizens; acknowledge and address citizens' experiences of power imbalances between citizens and professionals; invest in citizens who feel they lack the skills and confidence to engage; create quick and tangible wins; take into account both citizens' and organisations' motivations. An especially important thread throughout the CE literature is the influence of power imbalances and organisations' willingness, or not, to address such imbalances. The literature suggests that 'meaningful participation' of citizens can only be achieved if organisational processes are adapted to ensure that they are inclusive, accessible and supportive of citizens.

  19. Realistic modelling of observed seismic motion in complex sedimentary basins

    International Nuclear Information System (INIS)

    Faeh, D.; Panza, G.F.

    1994-03-01

    Three applications of a numerical technique are illustrated to model realistically the seismic ground motion for complex two-dimensional structures. First we consider a sedimentary basin in the Friuli region, and we model strong motion records from an aftershock of the 1976 earthquake. Then we simulate the ground motion caused in Rome by the 1915, Fucino (Italy) earthquake, and we compare our modelling with the damage distribution observed in the town. Finally we deal with the interpretation of ground motion recorded in Mexico City, as a consequence of earthquakes in the Mexican subduction zone. The synthetic signals explain the major characteristics (relative amplitudes, spectral amplification, frequency content) of the considered seismograms, and the space distribution of the available macroseismic data. For the sedimentary basin in the Friuli area, parametric studies demonstrate the relevant sensitivity of the computed ground motion to small changes in the subsurface topography of the sedimentary basin, and in the velocity and quality factor of the sediments. The total energy of ground motion, determined from our numerical simulation in Rome, is in very good agreement with the distribution of damage observed during the Fucino earthquake. For epicentral distances in the range 50km-100km, the source location and not only the local soil conditions control the local effects. For Mexico City, the observed ground motion can be explained as resonance effects and as excitation of local surface waves, and the theoretical and the observed maximum spectral amplifications are very similar. In general, our numerical simulations permit the estimate of the maximum and average spectral amplification for specific sites, i.e. are a very powerful tool for accurate micro-zonation. (author). 38 refs, 19 figs, 1 tab

  20. Realistic phantoms to characterize dosimetry in pediatric CT

    Energy Technology Data Exchange (ETDEWEB)

    Carver, Diana E.; Kost, Susan D.; Fraser, Nicholas D.; Pickens, David R.; Price, Ronald R.; Stabin, Michael G. [Vanderbilt University Medical Center, Department of Radiology and Radiological Sciences, Nashville, TN (United States); Segars, W.P. [Duke University, Carl E. Ravin Advanced Imaging Laboratories, Durham, NC (United States)

    2017-05-15

    The estimation of organ doses and effective doses for children receiving CT examinations is of high interest. Newer, more realistic anthropomorphic body models can provide information on individual organ doses and improved estimates of effective dose. Previously developed body models representing 50th-percentile individuals at reference ages (newborn, 1, 5, 10 and 15 years) were modified to represent 10th, 25th, 75th and 90th height percentiles for both genders and an expanded range of ages (3, 8 and 13 years). We calculated doses for 80 pediatric reference phantoms from simulated chest-abdomen-pelvis exams on a model of a Philips Brilliance 64 CT scanner. Individual organ and effective doses were normalized to dose-length product (DLP) and fit as a function of body diameter. We calculated organ and effective doses for 80 reference phantoms and plotted them against body diameter. The data were well fit with an exponential function. We found DLP-normalized organ dose to correlate strongly with body diameter (R{sup 2}>0.95 for most organs). Similarly, we found a very strong correlation with body diameter for DLP-normalized effective dose (R{sup 2}>0.99). Our results were compared to other studies and we found average agreement of approximately 10%. We provide organ and effective doses for a total of 80 reference phantoms representing normal-stature children ranging in age and body size. This information will be valuable in replacing the types of vendor-reported doses available. These data will also permit the recording and tracking of individual patient doses. Moreover, this comprehensive dose database will facilitate patient matching and the ability to predict patient-individualized dose prior to examination. (orig.)

  1. Realistic Goals and Processes for Future Space Astronomy Portfolio Planning

    Science.gov (United States)

    Morse, Jon

    2015-08-01

    It is generally recognized that international participation and coordination is highly valuable for maximizing the scientific impact of modern space science facilities, as well as for cost-sharing reasons. Indeed, all large space science missions, and most medium and small missions, are international, even if one country or space agency has a clear leadership role and bears most of the development costs. International coordination is a necessary aspect of future mission planning, but how that coordination is done remains debatable. I propose that the community's scientific vision is generally homogeneous enough to permit international coordination of decadal-scale strategic science goals. However, the timing and budget allocation/funding mechanisms of individual countries and/or space agencies are too disparate for effective long-term strategic portfolio planning via a single international process. Rather, I argue that coordinated space mission portfolio planning is a natural consequence of international collaboration on individual strategic missions. I review the process and outcomes of the U.S. 2010 decadal survey in astronomy & astrophysics from the perspective of a government official who helped craft the survey charter and transmitted guidance to the scientific community on behalf of a sponsoring agency (NASA), while continuing to manage the current portfolio that involved ongoing negotiations with other space agencies. I analyze the difficulties associated with projecting long-term budgets, obtaining realistic mission costs (including the additional cost burdens of international partnerships), and developing new (possibly transformational) technologies. Finally, I remark on the future role that privately funded space science missions can have in accomplishing international science community goals.

  2. Arterial occlusion to treat basilar artery dissecting aneurysm

    NARCIS (Netherlands)

    Cui, Qing Ke; Liu, Wei Dong; Liu, Peng; Li, Xue Yuan; Zhang, Lian Qun; Ma, Long Jia; Ren, Yun Fei; Wu, Ya Ping; Wang, Zhi Gang

    2015-01-01

    Object: To explore the clinical feasibility of employing occlusion to treat basilar artery dissecting aneurysm. Methods: One patient, male and 46 years old, suffered transient numbness and weakness on the right limbs. Cerebral angiography indicated basilar artery dissecting aneurysm. The patient

  3. Association between internal carotid artery dissection and arterial tortuosity

    International Nuclear Information System (INIS)

    Saba, Luca; Piga, Mario; Argiolas, Giovanni Maria; Siotto, Paolo; Sumer, Suna; Wintermark, Max; Raz, Eytan; Sanfilippo, Roberto; Montisci, Roberto

    2015-01-01

    Carotid artery dissection is an important cause of ischemic stroke in all age groups, particularly in young patients. The purpose of this work was to assess whether there is an association between the presence of an internal carotid artery dissection (ICAD) and the arterial tortuosity. This study considered 124 patients (72 males and 52 females; median age 57 years) with CT/MR diagnosis of ICAD of the internal carotid artery were considered in this multi-centric retrospective study. The arterial tortuosity was evaluated and, when present, was categorized as elongation, kinking, or coiling. For each patient, both the right and left sides were considered for a total number of 248 arteries in order to have the same number of cases and controls. Fisher's exact test was applied to test the association between elongation, kinking, coiling, dissection, and the side affected by CAD. Fisher's exact test showed a statistically significant association between the ICAD and kinking (p = 0.0089) and coiling (p = 0.0251) whereas no statistically significant difference was found with arterial vessel elongation (p = 0.444). ICAD was more often seen on the left side compared to the right (p = 0.0001). These results were confirmed using both carotid arteries of the same patient as dependent parameter with p = 0.0012, 0.0129, and 0.3323 for kinking, coiling, and elongation, respectively. The presence of kinking and coiling is associated with ICAD. (orig.)

  4. Anomalous left the pulmonary dilemma coronary artery artery from a ...

    African Journals Online (AJOL)

    Anomalous origin ofthe left coronary artery from the pulmonary artery is an unusual congenital ... led us to review our experience of this anomaly over the past 10 years. During this .... New York: McGraw-Hill, 1978: 1345. 5. Bland EF, White PO, ...

  5. Association between internal carotid artery dissection and arterial tortuosity

    Energy Technology Data Exchange (ETDEWEB)

    Saba, Luca; Piga, Mario [Azienda Ospedaliero Universitaria (A.O.U.), Department of Radiology, Monserrato, Cagliari (Italy); Argiolas, Giovanni Maria; Siotto, Paolo [Azienda Ospedaliero Brotzu (A.O.B.), Department of Radiology, di Cagliari (Italy); Sumer, Suna; Wintermark, Max [Neuroradiology Division, Neuroradiology, UVA Department of Radiology, Charlottesville, VA (United States); Raz, Eytan [New York University School of Medicine, Department of Radiology, New York, NY (United States); Sapienza University of Rome, Department of Neurology and Psychiatry, Rome (Italy); Sanfilippo, Roberto; Montisci, Roberto [Azienda Ospedaliero Universitaria (A.O.U.), Department of Vascular Surgery, di Cagliari (Italy)

    2014-10-18

    Carotid artery dissection is an important cause of ischemic stroke in all age groups, particularly in young patients. The purpose of this work was to assess whether there is an association between the presence of an internal carotid artery dissection (ICAD) and the arterial tortuosity. This study considered 124 patients (72 males and 52 females; median age 57 years) with CT/MR diagnosis of ICAD of the internal carotid artery were considered in this multi-centric retrospective study. The arterial tortuosity was evaluated and, when present, was categorized as elongation, kinking, or coiling. For each patient, both the right and left sides were considered for a total number of 248 arteries in order to have the same number of cases and controls. Fisher's exact test was applied to test the association between elongation, kinking, coiling, dissection, and the side affected by CAD. Fisher's exact test showed a statistically significant association between the ICAD and kinking (p = 0.0089) and coiling (p = 0.0251) whereas no statistically significant difference was found with arterial vessel elongation (p = 0.444). ICAD was more often seen on the left side compared to the right (p = 0.0001). These results were confirmed using both carotid arteries of the same patient as dependent parameter with p = 0.0012, 0.0129, and 0.3323 for kinking, coiling, and elongation, respectively. The presence of kinking and coiling is associated with ICAD. (orig.)

  6. Peripheral artery disease in type II diabetes

    International Nuclear Information System (INIS)

    Ali, Z.; Ahmed, S.M.; Bhutto, A.R.; Chaudhry, A.; Munir, S.M.

    2012-01-01

    Objective: To determine the frequency of peripheral arterial disease (PAD) in type 2 diabetic patients. Study Design: Cross-sectional observational study. Place and Duration of Study: Diabetes Clinic, Medical Unit III, Jinnah Postgraduate Medical Centre, Karachi, from January to June 2010. Methodology:Three hundred and eighty seven (387) type II diabetic patients of either gender and any age were included. Patients with a previous history of trauma to the arterial vasculature, pregnancy and those who underwent in the study arterial graft procedures were excluded. Non-purposive convenient sampling technique was used to enroll patients in the study. PAD was diagnosed when ankle-brachial index (ABI) was less than 0.9. Ap-value of less than 0.05 was considered statistically significant. Results: Out of 387 studied patients, 128 were males (33.1%) and 259 were females (66.9%). Mean age was 52.22 +- 6.39 years. PAD was detected in 152 9.671 (22 - 76) years in the entire cohort. Mean duration of diabetes was 9.38 +- (39.28%) of the total study subjects. Thirty-one of 128 male patients (24.22%) had PAD disease while 121 out of 259 female patients (46.71%) had evidence of PAD (p = 0.001). Hypertension was a significantly associated factor (p = 0.002). Conclusion: A high frequency of PAD was observed in the diabetic population particularly with hypertension and more prevalent in females. (author)

  7. Arterial diameter during central volume depletion in humans

    DEFF Research Database (Denmark)

    Iversen, Helle Klingenberg; Madsen, P; Matzen, S

    1995-01-01

    The luminal diameter of the radial artery was followed by high frequency ultrasound during 50 degrees head-up tilt-induced central volume depletion in ten healthy subjects of whom six were tilted twice and pretreated with the serotonin receptor antagonist methysergide or placebo following a double...

  8. Biochemical characterization of blood plasma of coronary artery ...

    Indian Academy of Sciences (India)

    This study aimed to investigate the biochemical profile of blood plasma of patients with coronary artery disease (CAD) and angiographically normal subjects (controls) to determine biomarkers for their differentiation. In this double blind study, 5 mL venous blood was drawn before angiography from CAD patients (n=60) and ...

  9. Early autonomic changes in patients with newly diagnosed arterial hypertension

    Czech Academy of Sciences Publication Activity Database

    Fráňa, P.; Plachý, M.; Jurák, Pavel; Halámek, Josef; Řiháček, I.; Pinková, L.; Souček, M.; Bartošíková, L.; Fráňová, J.

    2010-01-01

    Roč. 28, e-Supplement A (2010), e450 ISSN 0263-6352. [European Meeting on Hypertension /20./. 18.06.2010-21.06.2010, Oslo] Institutional research plan: CEZ:AV0Z20650511 Keywords : arterial hypertension * blood pressure Subject RIV: FA - Cardiovascular Diseases incl. Cardiotharic Surgery

  10. Hepatic artery perfusion imaging

    International Nuclear Information System (INIS)

    Thrall, J.H.; Gyves, J.W.; Ziessman, H.A.; Ensminger, W.D.

    1985-01-01

    Organ and region-selective intra-arterial chemotherapy have been used for more than two decades to treat malignant neoplasms in the extremities, head and neck region, pelvis, liver, and other areas. Substantial evidence of improved response to regional chemotherapy now exists, but there are stringent requirements for successful application of the regional technique. First, the chemotherapeutic agent employed must have appropriate pharmacokinetic and pharmacodynamic properties. Second, the drug must be reliably delivered to the tumor-bearing area. This typically requires an arteriographic assessment of the vascular supply of the tumor, followed by placement of a therapeutic catheter and confirmation that the ''watershed'' perfusion distribution from the catheter truly encompasses the tumor. Optimal catheter placement also minimizes perfusion of nontarget organs. Radionuclide perfusion imaging with technetium 99m-labeled particles, either microspheres or macroaggregates of albumin, has become the method of choice for making these assessments. Catheter placement itself is considered by many to represent a type of ''therapeutic'' intervention. However, once the catheter is in the hepatic artery the radionuclide perfusion technique can be used to assess adjunctive pharmacologic maneuvers designed to further exploit the regional approach to chemotherapy. This chapter presents the technetium Tc 99m macroaggregated albumin method for assessing catheter placement and the pharmacokinetic rationale for regional chemotherapy, and discusses two promising avenues for further intervention

  11. Spontaneous Arterial Dissection.

    Science.gov (United States)

    Brandt, Tobias; Caplan, Louis

    2001-09-01

    There is no controlled study for the best treatment or management of cervico-cerebral artery dissection (CAD). Rationale initial empiric treatment in acute CAD to prevent secondary embolism is partial thromboplastin time (PTT)-guided anticoagulation by intravenous heparin followed by anticoagulation with warfarin. Carotid surgery for treatment of CAD is not recommended anymore with the possible exception of persisting severe stenosis of the proximal internal carotid artery (ICA). There could be use of carotid angioplasty by balloon dilatation and stenting in selected cases of severe cerebral hemodynamic impairment by bilateral CAD. Duration of secondary prophylaxis by anticoagulation is best guided by Doppler sonography follow-up, and should be continued until normalization of blood flow or until at least 1 year after the vessel is occluded. There is no evidence that pseudoaneurysms increase the risk for embolic complication, and there is no evidence for surgery or continuation of anticoagulation in patients with pseudoaneurysms. Caution should be recommended for exercises that involve excessive head movements (eg, bungee jumping, trampoline jumping, and chiropractic maneuvers). The patient should be informed that recurrent rate is low in nonfamilial cases. Doppler sonography is a low-cost and high-sensitivity method for patients at risk.

  12. Straight versus tortuous retinal arteries in relation to blood pressure and genetics

    DEFF Research Database (Denmark)

    Taarnhøj, N C B B; Munch, I C; Sander, B

    2008-01-01

    dizygotic same-sex healthy twin pairs, aged 20 to 46 years, who were characterised by determination of retinal vessel diameters, arterial blood pressure, blood glucose, body mass index, smoking habits and retinal arterial tortuosity, using a three-level grading scale (straight, wavy, tortuous). Heritability......BACKGROUND/AIMS: To assess the relative influence of genetic and environmental factors on retinal arterial tortuosity and the association between tortuosity and various health indices in healthy young to middle-aged persons. METHODS: This cross-sectional study included 57 monozygotic and 52...... accounting for the remaining 18% (CI(95 )8, 36%). Increasing values of mean arterial blood pressure and body mass index were both associated with decreasing levels of retinal arterial tortuosity. CONCLUSION: There was a large variation in tortuosity of retinal arteries in these healthy subjects...

  13. LEARNING AND THOUGHT PROCESSES IN REALISTIC MATHEMATICS INSTRUCTION

    NARCIS (Netherlands)

    Nelissen, J.; Tomic, W.

    2008-01-01

    This article deals with the various different approaches to mathematics and the influence that these approaches have had on the teaching of this subject. In addition to the three generally known schools of mathematics instruction - the mechanistic, the structuralistic and the empirical - the article

  14. Analysis, reconstruction and manipulation using arterial snakes

    KAUST Repository

    Li, Guo; Liu, Ligang; Zheng, Hanlin; Mitra, Niloy J.

    2010-01-01

    , and manipulating such arterial surfaces. The core of the algorithm is a novel deformable model, called arterial snake, that simultaneously captures the topology and geometry of the arterial objects. The recovered snakes produce a natural decomposition of the raw

  15. Genetics Home Reference: pulmonary arterial hypertension

    Science.gov (United States)

    ... Home Health Conditions Pulmonary arterial hypertension Pulmonary arterial hypertension Printable PDF Open All Close All Enable Javascript ... view the expand/collapse boxes. Description Pulmonary arterial hypertension is a progressive disorder characterized by abnormally high ...

  16. Quantitative analysis of regional myocardial performance in coronary artery disease

    Science.gov (United States)

    Stewart, D. K.; Dodge, H. T.; Frimer, M.

    1975-01-01

    Findings from a group of subjects with significant coronary artery stenosis are given. A group of controls determined by use of a quantitative method for the study of regional myocardial performance based on the frame-by-frame analysis of biplane left ventricular angiograms are presented. Particular emphasis was placed upon the analysis of wall motion in terms of normalized segment dimensions, timing and velocity of contraction. The results were compared with the method of subjective assessment used clinically.

  17. Betel nut chewing associated with increased risk of arterial stiffness.

    Science.gov (United States)

    Wei, Yu-Ting; Chou, Yu-Tsung; Yang, Yi-Ching; Chou, Chieh-Ying; Lu, Feng-Hwa; Chang, Chih-Jen; Wu, Jin-Shang

    2017-11-01

    Betel nut chewing is associated with certain cardiovascular outcomes. Subclinical atherosclerosis may be one link between betel nut chewing and cardiovascular risk. Few studies have examined the association between chewing betel nut and arterial stiffness. The aim of this study was thus to determine the relationship between betel nut chewing and arterial stiffness in a Taiwanese population. We enrolled 7540 eligible subjects in National Cheng Kung University Hospital from October 2006 to August 2009. The exclusion criteria included history of cerebrovascular events, coronary artery disease, and taking lipid-lowering drugs, antihypertensives, and hypoglycemic agents. Increased arterial stiffness was defined as brachial-ankle pulse wave velocity (baPWV) ≥1400cm/s. According to their habit of betel nut use, the subjects were categorized into non-, ex-, and current chewers. The prevalence of increased arterial stiffness was 32.7, 43.3, and 43.2% in non-, ex- and current chewers, respectively (p=0.011). Multiple logistic regression analysis revealed that ex-chewers (odds ratio [OR] 1.69, 95% confidence interval (CI)=1.08-2.65) and current chewers (OR 2.29, 95% CI=1.05-4.99) had elevated risks of increased arterial stiffness after adjustment for co-variables. Both ex- and current betel nut chewing were associated with a higher risk of increased arterial stiffness. Stopping betel nut chewing may thus potentially be beneficial to reduce cardiovascular risk, based on the principals of preventive medicine. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. The association of breast arterial calcification and metabolic syndrome

    Directory of Open Access Journals (Sweden)

    Seyma Yildiz

    2014-01-01

    Full Text Available OBJECTIVES: We investigated the relationship between metabolic syndrome and breast arterial calcification detected via mammography in a cohort of postmenopausal subjects. METHODS: Among 837 patients referred to our radiology department for mammographic screening, 310 postmenopausal females (105 patients with and 205 patients without breast arterial calcification aged 40 to 73 (mean 55.9±8.4 years were included in this study. The groups were compared with respect to clinical characteristics and metabolic syndrome criteria. Univariate and multivariate analyses identified the factors related to breast arterial calcification. RESULTS: Age, postmenopausal duration and the frequencies of diabetes mellitus, hypertension and metabolic syndrome were significantly higher in the subjects with breast arterial calcification than in those without (p<0.05. Multivariate analysis indicated that age (OR = 1.3, 95% CI = 1.1-1.6, p = 0.001 and metabolic syndrome (OR = 4.0, 95% CI = 1.5−10.4, p = 0.005 were independent predictors of breast arterial calcification detected via mammography. The independent predictors among the features of metabolic syndrome were low levels of high-density lipoproteins (OR = 8.1, 95% CI = 1.0−64.0, p = 0.047 and high blood pressure (OR = 8.7, 95% CI = 1.5−49.7, p = 0.014. CONCLUSIONS: The likelihood of mammographic detection of breast arterial calcification increases with age and in the presence of hypertension or metabolic syndrome. For patients undergoing screening mammography who present with breast arterial calcification, the possibility of metabolic syndrome should be considered. These patients should be informed of their cardiovascular risk factors and counseled on appropriate lifestyle changes.

  19. Giant true celiac artery aneurysm

    International Nuclear Information System (INIS)

    Aljabri, Badr

    2009-01-01

    Celiac artery aneurysms are rare and usually asymptomatic. The management of these aneurysms is challenging, especially when they are large and involve the confluence of the trifurcation. We present here a case of a large celiac artery aneurysm involving its branches in a young woman. Preoperative investigations, intraoperative findings, and the operative procedure are also presented and discussed. (author

  20. Segmental hepatic artery at hepatic hilar area. Analysis by 3 dimensional integrated image of artery, portal vein and bile duct

    Energy Technology Data Exchange (ETDEWEB)

    Sakai, Hisamune; Okuda, Kouji; Yoshida, Jun; Kinoshita, Hisafumi; Aoyagi, Shigeaki [Kurume Univ., School of Medicine, Kurume, Fukuoka (Japan)

    2006-11-15

    Multiple individual variations in running and bifurcation of the hepatic artery, biliary duct and portal vein are known in hepatic hilar area. This paper describes the examination of such arterial variations by integrating the 3D images of those vessels obtained by multidetector-row CT (MDCT). Subjects are findings from 64 patients with cholangiocarcinoma, hepatocarcinoma or cholelithiasis. MDCT dynamic scanning, and percutaneous transhepatic biliary drainage-CT and/or drip infusion cholangiography-CT with the intravenous iopamidol and/or iotroxate megulumin, were done with GE LightSpeed Ultra 16 slice type equipment to compose the 3D images. Arterial variants of the bifurcation in the right and left lobe were found to be 18 cases/62 (29%) and 13/64 (20%), respectively. The left artery running at right side of portal venous umbilical region was seen in 9/64 (14%) and right artery running ''northward'', in 9/62 (14%). Previous realization of such individual 3D arterial variations as above is necessary for the precise microsurgery of the hilar area to preserve the essential vessel. (T.I.)

  1. Segmental hepatic artery at hepatic hilar area. Analysis by 3 dimensional integrated image of artery, portal vein and bile duct

    International Nuclear Information System (INIS)

    Sakai, Hisamune; Okuda, Kouji; Yoshida, Jun; Kinoshita, Hisafumi; Aoyagi, Shigeaki

    2006-01-01

    Multiple individual variations in running and bifurcation of the hepatic artery, biliary duct and portal vein are known in hepatic hilar area. This paper describes the examination of such arterial variations by integrating the 3D images of those vessels obtained by multidetector-row CT (MDCT). Subjects are findings from 64 patients with cholangiocarcinoma, hepatocarcinoma or cholelithiasis. MDCT dynamic scanning, and percutaneous transhepatic biliary drainage-CT and/or drip infusion cholangiography-CT with the intravenous iopamidol and/or iotroxate megulumin, were done with GE LightSpeed Ultra 16 slice type equipment to compose the 3D images. Arterial variants of the bifurcation in the right and left lobe were found to be 18 cases/62 (29%) and 13/64 (20%), respectively. The left artery running at right side of portal venous umbilical region was seen in 9/64 (14%) and right artery running ''northward'', in 9/62 (14%). Previous realization of such individual 3D arterial variations as above is necessary for the precise microsurgery of the hilar area to preserve the essential vessel. (T.I.)

  2. Realistic respiratory motion margins for external beam partial breast irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Conroy, Leigh; Quirk, Sarah [Department of Medical Physics, Tom Baker Cancer Centre, Calgary, Alberta T2N 4N2 (Canada); Department of Physics and Astronomy, University of Calgary, Calgary, Alberta T2N 1N4 (Canada); Smith, Wendy L., E-mail: wendy.smith@albertahealthservices.ca [Department of Medical Physics, Tom Baker Cancer Centre, Calgary, Alberta T2N 4N2 (Canada); Department of Physics and Astronomy, University of Calgary, Calgary, Alberta T2N 1N4 (Canada); Department of Oncology, University of Calgary, Calgary, Alberta T2N 1N4 (Canada)

    2015-09-15

    Purpose: Respiratory margins for partial breast irradiation (PBI) have been largely based on geometric observations, which may overestimate the margin required for dosimetric coverage. In this study, dosimetric population-based respiratory margins and margin formulas for external beam partial breast irradiation are determined. Methods: Volunteer respiratory data and anterior–posterior (AP) dose profiles from clinical treatment plans of 28 3D conformal radiotherapy (3DCRT) PBI patient plans were used to determine population-based respiratory margins. The peak-to-peak amplitudes (A) of realistic respiratory motion data from healthy volunteers were scaled from A = 1 to 10 mm to create respiratory motion probability density functions. Dose profiles were convolved with the respiratory probability density functions to produce blurred dose profiles accounting for respiratory motion. The required margins were found by measuring the distance between the simulated treatment and original dose profiles at the 95% isodose level. Results: The symmetric dosimetric respiratory margins to cover 90%, 95%, and 100% of the simulated treatment population were 1.5, 2, and 4 mm, respectively. With patient set up at end exhale, the required margins were larger in the anterior direction than the posterior. For respiratory amplitudes less than 5 mm, the population-based margins can be expressed as a fraction of the extent of respiratory motion. The derived formulas in the anterior/posterior directions for 90%, 95%, and 100% simulated population coverage were 0.45A/0.25A, 0.50A/0.30A, and 0.70A/0.40A. The differences in formulas for different population coverage criteria demonstrate that respiratory trace shape and baseline drift characteristics affect individual respiratory margins even for the same average peak-to-peak amplitude. Conclusions: A methodology for determining population-based respiratory margins using real respiratory motion patterns and dose profiles in the AP direction was

  3. Optimizing Wind And Hydropower Generation Within Realistic Reservoir Operating Policy

    Science.gov (United States)

    Magee, T. M.; Clement, M. A.; Zagona, E. A.

    2012-12-01

    Previous studies have evaluated the benefits of utilizing the flexibility of hydropower systems to balance the variability and uncertainty of wind generation. However, previous hydropower and wind coordination studies have simplified non-power constraints on reservoir systems. For example, some studies have only included hydropower constraints on minimum and maximum storage volumes and minimum and maximum plant discharges. The methodology presented here utilizes the pre-emptive linear goal programming optimization solver in RiverWare to model hydropower operations with a set of prioritized policy constraints and objectives based on realistic policies that govern the operation of actual hydropower systems, including licensing constraints, environmental constraints, water management and power objectives. This approach accounts for the fact that not all policy constraints are of equal importance. For example target environmental flow levels may not be satisfied if it would require violating license minimum or maximum storages (pool elevations), but environmental flow constraints will be satisfied before optimizing power generation. Additionally, this work not only models the economic value of energy from the combined hydropower and wind system, it also captures the economic value of ancillary services provided by the hydropower resources. It is recognized that the increased variability and uncertainty inherent with increased wind penetration levels requires an increase in ancillary services. In regions with liberalized markets for ancillary services, a significant portion of hydropower revenue can result from providing ancillary services. Thus, ancillary services should be accounted for when determining the total value of a hydropower system integrated with wind generation. This research shows that the end value of integrated hydropower and wind generation is dependent on a number of factors that can vary by location. Wind factors include wind penetration level

  4. Realistic respiratory motion margins for external beam partial breast irradiation

    International Nuclear Information System (INIS)

    Conroy, Leigh; Quirk, Sarah; Smith, Wendy L.

    2015-01-01

    Purpose: Respiratory margins for partial breast irradiation (PBI) have been largely based on geometric observations, which may overestimate the margin required for dosimetric coverage. In this study, dosimetric population-based respiratory margins and margin formulas for external beam partial breast irradiation are determined. Methods: Volunteer respiratory data and anterior–posterior (AP) dose profiles from clinical treatment plans of 28 3D conformal radiotherapy (3DCRT) PBI patient plans were used to determine population-based respiratory margins. The peak-to-peak amplitudes (A) of realistic respiratory motion data from healthy volunteers were scaled from A = 1 to 10 mm to create respiratory motion probability density functions. Dose profiles were convolved with the respiratory probability density functions to produce blurred dose profiles accounting for respiratory motion. The required margins were found by measuring the distance between the simulated treatment and original dose profiles at the 95% isodose level. Results: The symmetric dosimetric respiratory margins to cover 90%, 95%, and 100% of the simulated treatment population were 1.5, 2, and 4 mm, respectively. With patient set up at end exhale, the required margins were larger in the anterior direction than the posterior. For respiratory amplitudes less than 5 mm, the population-based margins can be expressed as a fraction of the extent of respiratory motion. The derived formulas in the anterior/posterior directions for 90%, 95%, and 100% simulated population coverage were 0.45A/0.25A, 0.50A/0.30A, and 0.70A/0.40A. The differences in formulas for different population coverage criteria demonstrate that respiratory trace shape and baseline drift characteristics affect individual respiratory margins even for the same average peak-to-peak amplitude. Conclusions: A methodology for determining population-based respiratory margins using real respiratory motion patterns and dose profiles in the AP direction was

  5. The relative greenhouse gas impacts of realistic dietary choices

    International Nuclear Information System (INIS)

    Berners-Lee, M.; Hoolohan, C.; Cammack, H.; Hewitt, C.N.

    2012-01-01

    The greenhouse gas (GHG) emissions embodied in 61 different categories of food are used, with information on the diet of different groups of the population (omnivorous, vegetarian and vegan), to calculate the embodied GHG emissions in different dietary scenarios. We calculate that the embodied GHG content of the current UK food supply is 7.4 kg CO 2 e person −1 day −1 , or 2.7 t CO 2 e person −1 y −1 . This gives total food-related GHG emissions of 167 Mt CO 2 e (1 Mt=10 6 metric tonnes; CO 2 e being the mass of CO 2 that would have the same global warming potential, when measured over 100 years, as a given mixture of greenhouse gases) for the entire UK population in 2009. This is 27% of total direct GHG emissions in the UK, or 19% of total GHG emissions from the UK, including those embodied in goods produced abroad. We calculate that potential GHG savings of 22% and 26% can be made by changing from the current UK-average diet to a vegetarian or vegan diet, respectively. Taking the average GHG saving from six vegetarian or vegan dietary scenarios compared with the current UK-average diet gives a potential national GHG saving of 40 Mt CO 2 e y −1 . This is equivalent to a 50% reduction in current exhaust pipe emissions from the entire UK passenger car fleet. Hence realistic choices about diet can make substantial differences to embodied GHG emissions. - Highlights: ► We calculate the greenhouse gas emissions embodied in different diets. ► The embodied GHG content of the current UK food supply is 7.4 kg CO 2 e person −1 day −1 . ► Changing to a vegetarian or vegan diet reduces GHG emissions by 22–26%. ► Changing to a vegetarian or vegan diet would reduce UK GHG emissions by 40 Mt CO 2 e y −1 .

  6. Obesity and overweight associated with increased carotid diameter and decreased arterial function in young otherwise healthy men.

    Science.gov (United States)

    Kappus, Rebecca M; Fahs, Christopher A; Smith, Denise; Horn, Gavin P; Agiovlasitis, Stomatis; Rossow, Lindy; Jae, Sae Y; Heffernan, Kevin S; Fernhall, Bo

    2014-04-01

    Obesity is linked to cardiovascular disease, stroke, increased mortality and vascular remodeling. Although increased arterial diameter is associated with multiple cardiovascular risk factors and obesity, it is unknown whether lumen enlargement is accompanied by unfavorable vascular changes in young and otherwise healthy obese individuals. The purpose of this study was to compare carotid and brachial artery diameter, blood pressure, arterial stiffness, and endothelial function in young, apparently healthy, normal-weight, overweight, and obese male subjects. One hundred sixty-five male subjects (27.39±0.59 years) were divided into 3 groups (normal weight, overweight, and obese) according to body mass index. Subjects underwent cardiovascular measurements to determine arterial diameter, function, and stiffness. After adjusting for age, the obese group had significantly greater brachial, carotid, and aortic pressures, brachial pulse wave velocity, carotid intima media thickness, and carotid arterial diameter compared with both the overweight and normal-weight groups. Obesity is associated with a much worse arterial profile, as an increased carotid lumen size was accompanied by higher blood pressure, greater arterial stiffness, and greater carotid intima media thickness in obese compared with overweight or normal-weight individuals. These data suggest that although obesity may be a factor in arterial remodeling, such remodeling is also accompanied by other hemodynamic and arterial changes consistent with reduced arterial function and increased cardiovascular risk.

  7. Texture and savoury taste influences on food intake in a realistic hot lunch time meal.

    Science.gov (United States)

    Forde, C G; van Kuijk, N; Thaler, T; de Graaf, C; Martin, N

    2013-01-01

    Previous studies with model foods have shown that softer textures lead to higher eating rates and higher ad libitum food intake and higher intensity of salt taste has been shown to result in a lower ad libitum food intake. These observations have yet to be replicated in the context of realistic solid hot meal components. The objective of the present study was to assess the effect of texture and taste on the ad libitum intake of a realistic hot lunchtime meal. The meals consisted of potatoes, carrots, steak and gravy varied according to a 2 (texture: mashed vs. whole) × 2 (taste: standard taste vs. strong taste) design. The texture dimension referred to mashed potatoes, mashed carrots and pieces of steak vs. whole boiled potatoes, whole boiled carrots and whole steak. The taste was varied by manipulating the taste intensity of the gravy to be either standard or high intensity savoury taste. The current study used a between groups, single course ad libitum design whereby subjects were recruited for a one off meal study, during which their food intake was measured. The four groups consisted of about 40 subjects (mashed, standard, n=37; mashed, savoury n=39; whole, standard n=40; and whole, savoury n=41) matched for age (average age=44.8 ± 5.3), gender (on average 19 males and 20 females), normal BMI (average 22.6 ± 1.7) and dietary restraint score (DEBQ score=1.74 ± 0.6). The results showed that the estimated means of the intake of the two mashed conditions was 563.2 ± 20.3g and intake of whole meal was 527.5 ± 20.0 g (p=0.23). The texture effect was significant in the higher savoury condition with an average of 91 g less food consumed in the solid-savoury meal than in the mashed-savoury meal. This effect was not replicated in the standard gravy condition, with no significant difference between solid and mashed textures. This was reflected in an interaction effect that was approaching significance (p=0.051). The estimated mean eating rate in the two mashed

  8. Prediction of coronary artery calcium progression by FDG uptake of large arteries in asymptomatic individuals

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Sang-Geon; Park, Ki Seong; Kim, Jahae; Song, Ho-Chun [Chonnam National University Hospital, Department of Nuclear Medicine, Gwang-ju (Korea, Republic of); Kang, Sae-Ryung; Kwon, Seong Young; Jabin, Zeenat; Kim, Young Jae; Jeong, Geum-Cheol; Song, Minchul; Min, Jung-Joon; Bom, Hee-Seung [Chonnam National University Hwasun Hospital, Department of Nuclear Medicine, Hwasun-gun, Jeollanam-do (Korea, Republic of); Seon, Hyun Ju [Chonnam National University Hwasun Hospital, Department of Radiology, Hwasun-gun, Jeollanam-do (Korea, Republic of)

    2017-01-15

    The purpose of this study is to evaluate whether fluorodeoxyglucose (FDG) uptake of the large arteries can predict coronary artery calcium (CAC) progression in asymptomatic individuals. Ninety-six asymptomatic individuals who underwent FDG positron emission tomography (PET) and CAC scoring on the same day for health screening and follow-up CAC scoring ≥1 year after baseline studies (mean 4.3 years) were included. Vascular FDG uptake was measured and corrected for blood pool activity to obtain peak and average target-to-blood pool ratios (TBRpeak and TBRavg, respectively) for the carotid arteries, and ascending and abdominal aorta. CAC scores at baseline and follow-up of each individual were measured and absolute CAC change (ΔCAC), annual CAC change (ΔCAC/year), and annual CAC change rate (ΔCAC%/year) were calculated. CAC progression was defined as ΔCAC >0 for individuals with negative baseline CAC; ΔCAC/year ≥10 for those with baseline CAC of 0subjects showed CAC progression. CAC-progressors showed significantly higher TBRpeak and TBRavg as compared to non-CAC-progressors for all three arteries. TBRpeak of the abdominal aorta was significantly associated with CAC progression in multivariate analysis, with age and baseline CAC. A higher TBRpeak of the abdominal aorta (≥2.11) was associated with CAC progression among subjects with negative baseline CAC only. In subjects with positive baseline CAC, only the amount of baseline CAC was significantly associated with CAC progression. However, the positive predictive value of the TBRpeak of the abdominal aorta was <40 % when age was <58 or baseline CAC was negative. Higher FDG uptake of the large arteries is

  9. Patent arterial duct

    Directory of Open Access Journals (Sweden)

    Martin Robin P

    2009-07-01

    Full Text Available Abstract Patent arterial duct (PAD is a congenital heart abnormality defined as persistent patency in term infants older than three months. Isolated PAD is found in around 1 in 2000 full term infants. A higher prevalence is found in preterm infants, especially those with low birth weight. The female to male ratio is 2:1. Most patients are asymptomatic when the duct is small. With a moderate-to-large duct, a characteristic continuous heart murmur (loudest in the left upper chest or infraclavicular area is typical. The precordium may be hyperactive and peripheral pulses are bounding with a wide pulse pressure. Tachycardia, exertional dyspnoea, laboured breathing, fatigue or poor growth are common. Large shunts may lead to failure to thrive, recurrent infection of the upper respiratory tract and congestive heart failure. In the majority of cases of PAD there is no identifiable cause. Persistence of the duct is associated with chromosomal aberrations, asphyxia at birth, birth at high altitude and congenital rubella. Occasional cases are associated with specific genetic defects (trisomy 21 and 18, and the Rubinstein-Taybi and CHARGE syndromes. Familial occurrence of PAD is uncommon and the usual mechanism of inheritance is considered to be polygenic with a recurrence risk of 3%. Rare families with isolated PAD have been described in which the mode of inheritance appears to be dominant or recessive. Familial incidence of PAD has also been linked to Char syndrome, familial thoracic aortic aneurysm/dissection associated with patent arterial duct, and familial patent arterial duct and bicuspid aortic valve associated with hand abnormalities. Diagnosis is based on clinical examination and confirmed with transthoracic echocardiography. Assessment of ductal blood flow can be made using colour flow mapping and pulsed wave Doppler. Antenatal diagnosis is not possible, as PAD is a normal structure during antenatal life. Conditions with signs and symptoms of

  10. The Realistic Job Preview as a Persuasive Communication.

    Science.gov (United States)

    1982-02-01

    10. PROGRAM ELEMENT, PROJECT. TAK AREA 6 WORK UNIT NUMBERS Michigan State Uiversity NR 170-894 Ii. CONTROLLING OFFICE NAME AND ADDRESS IS. REPORT...RJP research seems to show a stronger preview effect using more intelligent subjects. That is, studies of life insurance agents (Weitz, 1956; Youngberg...University Department of Psychological Sciences west Lafayette, INl 47907 1 Dr. Philip G. Zi±bardo*2 ~ Staniford Uiversity Department of Psychology Stanford, CA 94305 <El

  11. From Realistic to Primitive Models: A Primitive Model of Methanol

    Czech Academy of Sciences Publication Activity Database

    Vlček, Lukáš; Nezbeda, Ivo

    2003-01-01

    Roč. 101, č. 19 (2003), s. 2987-2996 ISSN 0026-8976 R&D Projects: GA AV ČR IAA4072303; GA AV ČR IAA4072309 Grant - others:NATO(XX) PST.CLG 978178/6343 Institutional research plan: CEZ:AV0Z4072921 Keywords : primitive model * methanol Subject RIV: CF - Physical ; Theoretical Chemistry Impact factor: 1.591, year: 2003

  12. A virtual shopping test for realistic assessment of cognitive function.

    Science.gov (United States)

    Okahashi, Sayaka; Seki, Keiko; Nagano, Akinori; Luo, Zhiwei; Kojima, Maki; Futaki, Toshiko

    2013-06-18

    Cognitive dysfunction caused by brain injury often prevents a patient from achieving a healthy and high quality of life. By now, each cognitive function is assessed precisely by neuropsychological tests. However, it is also important to provide an overall assessment of the patients' ability in their everyday life. We have developed a Virtual Shopping Test (VST) using virtual reality technology. The objective of this study was to clarify 1) the significance of VST by comparing VST with other conventional tests, 2) the applicability of VST to brain-damaged patients, and 3) the performance of VST in relation to age differences. The participants included 10 patients with brain damage, 10 age-matched healthy subjects for controls, 10 old healthy subjects, and 10 young healthy subjects. VST and neuropsychological tests/questionnaires about attention, memory and executive function were conducted on the patients, while VST and the Mini-Mental State Examination (MMSE) were conducted on the controls and healthy subjects. Within the VST, the participants were asked to buy four items in the virtual shopping mall quickly in a rational way. The score for evaluation included the number of items bought correctly, the number of times to refer to hints, the number of movements between shops, and the total time spent to complete the shopping. Some variables on VST correlated with the scores of conventional assessment about attention and everyday memory. The mean number of times referring to hints and the mean number of movements were significantly larger for the patients with brain damage, and the mean total time was significantly longer for the patients than for the controls. In addition, the mean total time was significantly longer for the old than for the young. The results suggest that VST is able to evaluate the ability of attention and everyday memory in patients with brain damage. The time of VST is increased by age.

  13. Delegitimizing Al-Qaeda: A Jihad-Realist Approach

    Science.gov (United States)

    2012-03-01

    Suite 1204, Arlington VA 22202-4302. Respondents should be aware that notwithstanding any other provision of law, no person shall be subject to a...unique “ brand ” of violent extremism: complex, simultaneous, multiple-target, mass casualty terrorist attacks directed at the U.S. 2 homeland.8 Short...Terror,” Studies in Conflict and Terrorism, Vol. 32, 2009, pp. 109-138; William D. Casebeer and James A Russell, “ Storytelling and Terrorism: Towards a

  14. Peripheral artery atherectomy

    International Nuclear Information System (INIS)

    Quesnel, C.; Maquin, P.; Railhac, N.; Lefevre, G.; Bossavy, J.B.; Railhac, J.J.

    1988-01-01

    Twenty-one femoropopliteal percutaneous transluminal atherectomies were performed with the Simpson catheter. Evaluation included clinical examination, Doppler ultrasonography (ankle-arm index, before and immediately and 1,3 and 6 months after atherectomy), and angiography (6 months after or for clinical worsening). Twenty of 21 procedures achieved satisfactory vessel patency, with the addition of complementary angioplasty for residual stenosis over 30% (one of three cases). Early thrombosis occurred in only one of 21 cases (absence of platelet inhibitor pretherapy), and no distal embolization occurred. Six-month follow-up showed stable improvements in 11 of 12 patients and restenosis in only one (absence of platelet inhibitor pretherapy). Preliminary results indicate that atherectomy is the method of choice for restoring large lumens, with minimal arterial wall injury and fewer cases of restenosis than with angioplasty

  15. Echocardiography in Arterial Hypertension.

    Science.gov (United States)

    de Simone, Giovanni; Mancusi, Costantino; Esposito, Roberta; De Luca, Nicola; Galderisi, Maurizio

    2018-05-02

    Hypertension is a condition characterized by pressure and/or volume overloads and echocardiography is helpful and feasible to understand hemodynamic mechanisms. Echocardiographic information is sometimes critical and susceptible of modifying decision making. In this review, we provide detailed descriptions of the parameters that can be derived from a standard transthoracic echocardiogram, including some more recent techniques. We will also explain how each parameter might have impact in the evaluation of the hypertensive patient and give indications on when to refer patients to echo-labs, which parameters are critical and which ones might be redundant, and how to use the information obtained in the report. Cardiac geometry, LV systolic and diastolic function, LV pump performance, output impedance and left atrial function are parameters that might be altered in arterial hypertension, but not necessarily doctors need the whole information for decision making. The critical measures are provided.

  16. [Exercise in arterial hypertension].

    Science.gov (United States)

    Predel, Hans-Georg; Schramm, Thomas

    2006-09-01

    Regular endurance training has established itself as a major therapeutic principle in the specter of nonpharmacological measures in arterial hypertension. An initial medical check as well as an adequate technique, dosage and intensity of the prescribed exercise training are mandatory. With respect to the concomitant pharmacological treatment, it should be considered that the beneficial effects of lifestyle modification will not be counteracted by the chosen antihypertensive drug but, ideally, synergistically supported. Based on the individual clinical situation, principally all antihypertensive drugs recommended by the current European guidelines, may be prescribed as mono- or combination therapy.beta-receptor blockers are especially capable of controlling excessive exercise-induced blood pressure increase; however, they have metabolic and exercise physiological limitations. The neutrality concerning metabolic and exercise physiological parameters as well as the positive profile of side effects favor ACE inhibitors, long-acting calcium channel blockers and especially AT(1) antagonists in physically active hypertensive patients with concomitant metabolic syndrome.

  17. Coronary Artery Disease

    DEFF Research Database (Denmark)

    Christiansen, Morten Krogh

    2017-01-01

    A family history of coronary artery disease (CAD) is an important risk factor for adverse coronary events, in particular if the disease has an early onset. The risk of CAD is influenced by genetic and environmental factors with a greater genetic contribution earlier in life. Through recent years......), and to characterize and quantify subclinical atherosclerosis in their relatives. Furthermore, the aim was to explore the impact of common genetic risk variants on the age of onset, familial clustering and disease severity. In study I, 143 patients with early- onset CAD were recruited from the Western Denmark Heart...... Registry and risk factor control was evaluated. The study revealed that risk factors are common in early-onset CAD and that a large room for risk factor improvement remains. In study II, we used coronary computed tomography angiography to compare the coronary plaque burden and characteristics between 88...

  18. Analysis of Heterogeneous Networks with Dual Connectivity in a Realistic Urban Deployment

    DEFF Research Database (Denmark)

    Gerardino, Guillermo Andrés Pocovi; Barcos, Sonia; Wang, Hua

    2015-01-01

    the performance in this realistic layout. Due to the uneven load distribution observed in realistic deployments, DC is able to provide fast load balancing gains also at relatively high load - and not only at low load as typically observed in 3GPP scenarios. For the same reason, the proposed cell selection...

  19. Realist review and synthesis of retention studies for health workers in rural and remote areas

    NARCIS (Netherlands)

    Dieleman, M.A.; Kane, Sumit; Zwanikken, Prisca A C; Gerretsen, Barend

    2011-01-01

    This report uses a realist review, which is a theory-based method, to address the questions of “why” and “how” certain rural retention interventions work better in some contexts and fail in others. Through applying a realist perspective to the review of these retention studies, a greater

  20. Neutron star models with realistic high-density equations of state

    International Nuclear Information System (INIS)

    Malone, R.C.; Johnson, M.B.; Bethe, H.A.

    1975-01-01

    We calculate neutron star models using four realistic high-density models of the equation of state. We conclude that the maximum mass of a neutron star is unlikely to exceed 2 M/sub sun/. All of the realistic models are consistent with current estimates of the moment of inertia of the Crab pulsar

  1. Retinal artery occlusion during carotid artery stenting with distal embolic protection device.

    Science.gov (United States)

    Kohara, Kotaro; Ishikawa, Tatsuya; Kobayashi, Tomonori; Kawamata, Takakazu

    2018-01-01

    Retinal artery occlusion associated with carotid artery stenosis is well known. Although it can also occur at the time of carotid artery stenting, retinal artery occlusion via the collateral circulation of the external carotid artery is rare. We encountered two cases of retinal artery occlusion that were thought to be caused by an embolus from the external carotid artery during carotid artery stenting with a distal embolic protection device for the internal carotid artery. A 71-year-old man presented with central retinal artery occlusion after carotid artery stenting using the Carotid Guardwire PS and a 77-year-old man presented with branch retinal artery occlusion after carotid artery stenting using the FilterWire EZ. Because additional new cerebral ischaemic lesions were not detected in either case by postoperative diffusion-weighted magnetic resonance imaging, it was highly likely that the debris that caused retinal artery occlusion passed through not the internal carotid artery but collaterals to retinal arteries from the external carotid artery, which was not protected by a distal embolic protection device. It is suggested that a distal protection device for the internal carotid artery alone cannot prevent retinal artery embolisation during carotid artery stenting and protection of the external carotid artery is important to avoid retinal artery occlusion.

  2. Do absorption and realistic distraction influence performance of component task surgical procedure?

    Science.gov (United States)

    Pluyter, Jon R; Buzink, Sonja N; Rutkowski, Anne-F; Jakimowicz, Jack J

    2010-04-01

    Surgeons perform complex tasks while exposed to multiple distracting sources that may increase stress in the operating room (e.g., music, conversation, and unadapted use of sophisticated technologies). This study aimed to examine whether such realistic social and technological distracting conditions may influence surgical performance. Twelve medical interns performed a laparoscopic cholecystectomy task with the Xitact LC 3.0 virtual reality simulator under distracting conditions (exposure to music, conversation, and nonoptimal handling of the laparoscope) versus nondistracting conditions (control condition) as part of a 2 x 2 within-subject experimental design. Under distracting conditions, the medical interns showed a significant decline in task performance (overall task score, task errors, and operating time) and significantly increased levels of irritation toward both the assistant handling the laparoscope in a nonoptimal way and the sources of social distraction. Furthermore, individual differences in cognitive style (i.e., cognitive absorption and need for cognition) significantly influenced the levels of irritation experienced by the medical interns. The results suggest careful evaluation of the social and technological sources of distraction in the operation room to reduce irritation for the surgeon and provision of proper preclinical laparoscope navigation training to increase security for the patient.

  3. Photo-Realistic Statistical Skull Morphotypes: New Exemplars for Ancestry and Sex Estimation in Forensic Anthropology.

    Science.gov (United States)

    Caple, Jodi; Stephan, Carl N

    2017-05-01

    Graphic exemplars of cranial sex and ancestry are essential to forensic anthropology for standardizing casework, training analysts, and communicating group trends. To date, graphic exemplars have comprised hand-drawn sketches, or photographs of individual specimens, which risks bias/subjectivity. Here, we performed quantitative analysis of photographic data to generate new photo-realistic and objective exemplars of skull form. Standardized anterior and left lateral photographs of skulls for each sex were analyzed in the computer graphics program Psychomorph for the following groups: South African Blacks, South African Whites, American Blacks, American Whites, and Japanese. The average cranial form was calculated for each photographic view, before the color information for every individual was warped to the average form and combined to produce statistical averages. These mathematically derived exemplars-and their statistical exaggerations or extremes-retain the high-resolution detail of the original photographic dataset, making them the ideal casework and training reference standards. © 2016 American Academy of Forensic Sciences.

  4. Simple gaze-contingent cues guide eye movements in a realistic driving simulator

    Science.gov (United States)

    Pomarjanschi, Laura; Dorr, Michael; Bex, Peter J.; Barth, Erhardt

    2013-03-01

    Looking at the right place at the right time is a critical component of driving skill. Therefore, gaze guidance has the potential to become a valuable driving assistance system. In previous work, we have already shown that complex gaze-contingent stimuli can guide attention and reduce the number of accidents in a simple driving simulator. We here set out to investigate whether cues that are simple enough to be implemented in a real car can also capture gaze during a more realistic driving task in a high-fidelity driving simulator. We used a state-of-the-art, wide-field-of-view driving simulator with an integrated eye tracker. Gaze-contingent warnings were implemented using two arrays of light-emitting diodes horizontally fitted below and above the simulated windshield. Thirteen volunteering subjects drove along predetermined routes in a simulated environment popu­ lated with autonomous traffic. Warnings were triggered during the approach to half of the intersections, cueing either towards the right or to the left. The remaining intersections were not cued, and served as controls. The analysis of the recorded gaze data revealed that the gaze-contingent cues did indeed have a gaze guiding effect, triggering a significant shift in gaze position towards the highlighted direction. This gaze shift was not accompanied by changes in driving behaviour, suggesting that the cues do not interfere with the driving task itself.

  5. Basilar artery aneurysm case presented with neck pain

    Directory of Open Access Journals (Sweden)

    Uygar Utku

    2013-04-01

    Full Text Available Neck pain related with disorders of the brain and neck vascular structures is not rare but importance was attached to a condition that is often overlooked. Tension as a sudden onset, radiating to the nape, the neck pain becomes unbearable and within seconds the raging 51-year-old female patient with aneurysm at the distal end of basilar artery was found. Case, the only sign of neck pain with unruptured basilar artery aneurysm is presented in terms of raising awareness on the subject.

  6. Reduced arterial diameter during static exercise in humans

    DEFF Research Database (Denmark)

    Olesen, H L; Mitchell, J H; Friedman, D B

    1995-01-01

    In eight subjects luminal diameter of the resting limb radial and dorsalis pedis arteries was determined by high-resolution ultrasound (20 MHz). This measurement was followed during rest and during 2 min of static handgrip or of one-leg knee extension at 30% of maximal voluntary contraction...... exertion was approximately 15 units after both types of exercise. The dorsalis pedis arterial diameter was 1.50 +/- 0.20 mm (mean and SE) and the radial AD 2.45 +/- 0.12 mm. During both types of contractions the luminal diameters decreased approximately 3.5% within the first 30 s (P

  7. Ultrasound evaluation of forearm arteries in patients undergoing percutaneous coronary intervention via radial artery access: results of one-year follow-up.

    Science.gov (United States)

    Peruga, Jan Przemysław; Peruga, Jan Zbigniew; Kasprzak, Jarosław D; Kręcki, Radosław; Jankowski, Łukasz; Zając, Piotr; Plewka, Michał

    2015-01-01

    A proven advantage of radial over femoral arterial access has led to an increase in the number of interventions performed via radial artery access in patients with acute coronary syndromes. Both assessment of the pulse volume and the Allen's test are subjective and subject to investigator bias. An ultrasound examination of the forearm arteries provides important information about the anatomy of the forearm vessels, and indirectly also about the efficiency of collateral blood supply to the hand. It also enables determination of the relevant vessel diameter before the planned intervention, and may be used to assess local complications. To assess the morphology of forearm blood vessels and measure the diameter of both radial and ulnar arteries at the cannulation site using ultrasound imaging. We also aimed to identify potential vascular anomalies and local complications associated with radial artery puncture. The study included 109 patients with cardiologic indications for coronary angiography or coronary angioplasty. An ultrasound evaluation of forearm arteries was performed prior to the intervention, and the vascular anatomy was later verified by angiography during the procedure. Ultrasound measurements of the vessel diameter were also performed and local complications of the cannulation were assessed. Measurements were performed immediately after the procedure and at 30 days and 12 months. Fifty-nine right and 50 left forearm arteries were evaluated. Women were 29% of the study population. The mean patient age was 59.2 ± 7.9 years. The mean diameter of the right radial artery was 2.17 ± 0.54 mm, and the mean diameter of the left radial artery was 2.25 ± 0.43 mm. The measurements revealed gender-related differences in forearm artery diameter (p = 0.003). Vascular anomalies of the radial artery were identified by ultrasound examination in 10% of subjects. A significant dilatation of the cannulated blood vessel was observed which lasted up to 12 months. An

  8. Studies on arterial stiffness and wave reflections in hypertension.

    Science.gov (United States)

    Safar, Michel E; Levy, Bernard I

    2015-01-01

    Patho-physiological and pharmacological studies have consistently noticed that, with the exception of subjects with end-stage renal disease, total intravascular blood volume is not increased in patients with chronic hypertension. Because the mean circulatory pressure is enhanced in such subjects, it was postulated that the compliance of the cardiovascular system could be abnormally low in this particular population. This simple observation has influenced a great part of our experimental and clinical research directed toward subjects with hypertension and their relationship with the compliance of the vascular system. These works started between 1970 and 1980 by methodological investigations and validations followed by analysis of clinical situations that showed that venous and mostly arterial stiffness were significantly increased in hypertensive patients independently of blood pressure level. During the same time, we assessed the role of endothelium on the large arterial wall mechanical properties in normotensive and hypertensive rats. Thereafter more specific directions have been developed, affecting large arteries structure and function and arterial wall remodeling, including their consequences on central and peripheral hemodynamics. In parallel, epidemiological studies identified the pulsatile hemodynamic parameters as major independent predictors of cardiovascular risks. The consequences of these alterations on clinical pharmacology and therapeutics in hypertension are analyzed in detail. © American Journal of Hypertension, Ltd 2014. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  9. Attitude change in a realistic experiment: the effect of party membership and audience reaction during an interview with a Dutch politician

    OpenAIRE

    Wiegman, O.

    1987-01-01

    In this realistic experiment, an interview with the leader of the Liberals in the Dutch Parliament was recorded in the presence of a live audience, which reacted in a positive, negative, or neutral way. It was shown to subjects of two opposing political parties, whose attitudes were to be changed by the experimental interview. The main hypothesis, which predicted more attitude change in the positive than in the negative audience condition, could not in general be supported. The alternative au...

  10. Optimal control of photoelectron emission by realistic waveforms

    Czech Academy of Sciences Publication Activity Database

    Solanpää, J.; Ciappina, Marcelo F.; Räsänen, J.

    2017-01-01

    Roč. 64, č. 17 (2017), s. 1784-1792 ISSN 0950-0340 R&D Projects: GA MŠk EF15_008/0000162; GA MŠk LQ1606 Grant - others:ELI Beamlines(XE) CZ.02.1.01/0.0/0.0/15_008/0000162 Institutional support: RVO:68378271 Keywords : above-threshold ionization * optimal control * waveforms Subject RIV: BL - Plasma and Gas Discharge Physics OBOR OECD: Fluids and plasma physics (including surface physics) Impact factor: 1.328, year: 2016

  11. Acute exposure to realistic acid fog: effects on respiratory function and airway responsiveness in asthmatics.

    Science.gov (United States)

    Leduc, D; Fally, S; De Vuyst, P; Wollast, R; Yernault, J C

    1995-11-01

    Naturally occurring fogs in industrialized cities are contaminated by acidic air pollutants. In Brussels, Belgium, the pH of polluted fogwater may be as low as 3 with osmolarity as low as 30 mOsm. In order to explore short-term respiratory effects of a realistic acid-polluted fog, we collected samples of acid fog in Brussels, Belgium, which is a densely populated and industrialized city, we defined characteristics of this fog and exposed asthmatic volunteers at rest through a face mask to fogs with physical and chemical characteristics similar to those of natural fogs assessed in this urban area. Fogwater was sampled using a screen collector where droplets are collected by inertial impaction and chemical content of fogwater was assessed by measurement of conductivity, pH, visible colorimetry, high pressure liquid chromatography, and atomic absorption spectrophotometry over a period of one year. The fogwater composition was dominated by NH4+ and SO4- ions. First we evaluated the possible effect of fog acidity alone. For this purpose 14 subjects with asthma were exposed at rest for 1 hr [mass median aerodynamic diameter to a large-particle (MMAD), 9 microns] aerosol with H2SO4 concentration of 500 micrograms/m3 (pH 2.5) and osmolarity of 300 mOsm. We did not observe significant change in pulmonary function or bronchial responsiveness to metacholine. In the second part of the work, 10 asthmatic subjects were exposed to acid fog (MMAD, 7 microns) containing sulfate and ammonium ions (major ions recovered in naturally occurring fogs) with pH 3.5 and osmolarity 30 mOsm. Again, pulmonary function and bronchial reactivity were not modified after inhalation of this fog. It was concluded that short-term exposure to acid fog reproducing acidity and hypoosmolarity of natural polluted fogs does not induce bronchoconstriction and does not change bronchial responsiveness in asthmatics.

  12. Cerebellar arteries originating from the internal carotid artery: angiographic evaluation and embryologic explanations

    International Nuclear Information System (INIS)

    Lee, Jae Young; Han, Moon Hee; Yu, In Gyu; Chang, Ki Hyun; Kim, Eui Jong; Kim, Dae Ho

    1997-01-01

    To find and describe the cerebellar arteries arising from the internal carotid artery, explain them embryologically, and evaluate their clinical implication. To determine the point in the internal carotid artery from which the cereballar artery arose anomalously, consecutive angiographic studies performed in the last three years were reviewed. The distribution of such anomalous cerebellar arteries, the point in the internal carotid artery from which the anomalous vessels originated, and associated findings were analyzed. Five anomalous origins of cerebellar arteries arising arising directly from the internal carotid artery were found in five patients. Three anterior inferior cerebellar arteries (AICA) and one common trunk of an AICA and a posterior inferior cerebellar artery (PICA) were found to originate from the internal carotid artery at a point close to the origin of the primitive trigeminal artery. A PICA arose from an artery presenting a course similar to the proatlantal intersegmental artery. Intracranial aneurysms in two patients, Moyamoya disease in one, and facial arteriovenous malformation in one. In our series, AICAs supplied from the arteries considered to be persistent trigeminal artery variants were the most common type. A correlation between type of anomalous cerebellar artery and type of carotid-vertebrobasilar anastomosis may exist. Cerebellar arteries originating anomalously from the internal carotid artery seem to occur as a result of the persistence of carotid-vertebrobasilar anastomoses associated with incomplete fusion of the longitudinal neural arteries. An understanding of these anomalous cerebellar arteries may help prevent accidents during therapeutic embolization and surgical treatment, as well as misinterpretation

  13. A subjective scheduler for subjective dedicated networks

    Science.gov (United States)

    Suherman; Fakhrizal, Said Reza; Al-Akaidi, Marwan

    2017-09-01

    Multiple access technique is one of important techniques within medium access layer in TCP/IP protocol stack. Each network technology implements the selected access method. Priority can be implemented in those methods to differentiate services. Some internet networks are dedicated for specific purpose. Education browsing or tutorial video accesses are preferred in a library hotspot, while entertainment and sport contents could be subjects of limitation. Current solution may use IP address filter or access list. This paper proposes subjective properties of users or applications are used for priority determination in multiple access techniques. The NS-2 simulator is employed to evaluate the method. A video surveillance network using WiMAX is chosen as the object. Subjective priority is implemented on WiMAX scheduler based on traffic properties. Three different traffic sources from monitoring video: palace, park, and market are evaluated. The proposed subjective scheduler prioritizes palace monitoring video that results better quality, xx dB than the later monitoring spots.

  14. Endoscopic Radial Artery Harvest for Coronary Artery Bypass Surgery

    Directory of Open Access Journals (Sweden)

    Kuan-Ming Chiu

    2006-01-01

    Conclusion: Endoscopic harvest of the radial artery is technically demanding, but excellent results can be achieved. The endoscopic approach can provide suitable conduits in a less invasive way than the open harvest technique.

  15. Anomalous Origin of Left Coronary Artery from Pulmonary Artery (ALCAPA)

    International Nuclear Information System (INIS)

    Younus, Z.; Ahmed, I.; Iftikhar, R.

    2013-01-01

    Anomalous origin of the left coronary artery from the pulmonary artery also recognized as Bland White Garland syndrome is a very rare congenital condition. A two-months old baby boy presented with dyspnoea for two weeks and a pansystolic murmur on auscultation. The base line investigations showed cardiomegaly and bilateral basal haze on X-ray chest. ECG showed ST elevation in leads l and AVl and echocardiography showed situs solitus, levocardia, hypokinetic intraventricular septum, ejection fraction of 30%, mitral regurgitation of grade-I and an anomalous origin of the left coronary artery from pulmonary artery was diagnosed. Patient was in left heart failure. It was rectified surgically by creating a transpulmonary tunnel (Takeuchi repair). Postoperative course was uneventful and he was finally discharged in stable condition. (author)

  16. Anomalous left coronary artery from the pulmonary artery

    Science.gov (United States)

    ... anomalies of mitral valve. In: Sellke FW, del Nido PJ, Swanson SJ, eds. Sabiston and Spencer Surgery ... of the coronary arteries. In: Sellke FW, del Nido PJ, Swanson SJ, eds. Sabiston and Spencer Surgery ...

  17. Arterial stiffness &Sri Lankan chronic kidney disease of unknown origin.

    Science.gov (United States)

    Gifford, Fiona; Kimmitt, Robert; Herath, Chula; Webb, David J; Melville, Vanessa; Siribaddana, Sisira; Eddleston, Michael; Dhaun, Neeraj

    2016-09-02

    Chronic kidney disease (CKD) is common and independently associated with cardiovascular disease (CVD). Arterial stiffness contributes to CVD risk in CKD. In many developing countries a considerable proportion of CKD remains unexplained, termed CKDu. We assessed arterial stiffness in subjects with Sri Lankan CKDu, in matched controls without CKD and in those with defined CKD. Aortic blood pressure (BP), pulse wave velocity (PWV) and augmentation index (AIx) were assessed in 130 subjects (50 with CKDu, 45 with CKD and 35 without CKD) using the validated TensioMed™ Arteriograph monitor. Brachial and aortic BP was lower in controls than in CKDu and CKD subjects but no different between CKDu and CKD. Controls had a lower PWV compared to subjects with CKDu and CKD. Despite equivalent BP and renal dysfunction, CKDu subjects had a lower PWV than those with CKD (8.7 ± 1.5 vs. 9.9 ± 2.2 m/s, p CKDu vs. CKD: 6.7 ± 0.9 vs. 8.7 ± 1.5 vs. 10.4 ± 1.5 m/s, p CKDu is associated with less arterial stiffening than defined causes of CKD. Whether this translates to lower cardiovascular morbidity and mortality long term is unclear and should be the focus of future studies.

  18. Embolisation of the splenic artery

    Energy Technology Data Exchange (ETDEWEB)

    Essler, G; Duex, A

    1982-09-01

    In bleeding of oesophageal varices with resistance to common treatment embolisation of the splenic artery causes depression of the portal hypertension by forty per cent. Thrombosis of the splenic or portal vein as in splenectomies are not to be expected. The splenic vein remains open for later spleno-renal anastomosis. By occlusion of the splenic artery we were successful in stopping oesophageal bleeding. In a patient with dominant hypersplenism in portal hypertension the severity of the syndrome decreased after embolisation of the splenic artery. Thrombocytes, leukocytes and gammaglobulin increased.

  19. Access to the ophthalmic artery by retrograde approach through the posterior communicating artery for intra-arterial chemotherapy of retinoblastoma

    Energy Technology Data Exchange (ETDEWEB)

    Pham, Chi-Tuan; Blanc, Raphael; Pistocchi, Silvia; Bartolini, Bruno; Piotin, Michel [Fondation Rothschild Hospital, Department of Interventional Neuroradiology, Paris (France); Lumbroso-Le Rouic, Livia [Institut Curie, Department of Ocular Oncology, Paris (France)

    2012-08-15

    Intra-arterial infusion of chemotherapy into the ophthalmic artery for treatment of retinoblastoma has been realized after catheterization of the internal carotid and temporary balloon occlusion beyond the orifice of the ophthalmic artery, or more recently after superselective canulation of the ophthalmic artery by a microcatheter. The superselective catheterization of the ophthalmic artery could be cumbersome because of the implantation of the ostium on the carotid siphon or because of the tortuosity of the carotid siphon. We report our experience of using a retrograde approach through the posterior communicating artery that allows a more direct angle of access to the origin of the ophthalmic artery. (orig.)

  20. Pulmonary arterial hypertension

    Science.gov (United States)

    2013-01-01

    Pulmonary arterial hypertension (PAH) is a chronic and progressive disease leading to right heart failure and ultimately death if untreated. The first classification of PH was proposed in 1973. In 2008, the fourth World Symposium on PH held in Dana Point (California, USA) revised previous classifications. Currently, PH is devided into five subgroups. Group 1 includes patients suffering from idiopathic or familial PAH with or without germline mutations. Patients with a diagnosis of PAH should systematically been screened regarding to underlying mutations of BMPR2 gene (bone morphogenetic protein receptor type 2) or more rarely of ACVRL1 (activine receptor-like kinase type 1), ENG (endogline) or Smad8 genes. Pulmonary veno occusive disease and pulmonary capillary hemagiomatosis are individualized and designated as clinical group 1'. Group 2 'Pulmonary hypertension due to left heart diseases' is divided into three sub-groups: systolic dysfonction, diastolic dysfonction and valvular dysfonction. Group 3 'Pulmonary hypertension due to respiratory diseases' includes a heterogenous subgroup of respiratory diseases like PH due to pulmonary fibrosis, COPD, lung emphysema or interstitial lung disease for exemple. Group 4 includes chronic thromboembolic pulmonary hypertension without any distinction of proximal or distal forms. Group 5 regroup PH patients with unclear multifactorial mechanisms. Invasive hemodynamic assessment with right heart catheterization is requested to confirm the definite diagnosis of PH showing a resting mean pulmonary artery pressure (mPAP) of ≥ 25 mmHg and a normal pulmonary capillary wedge pressure (PCWP) of ≤ 15 mmHg. The assessment of PCWP may allow the distinction between pre-capillary and post-capillary PH (PCWP > 15 mmHg). Echocardiography is an important tool in the management of patients with underlying suspicion of PH. The European Society of Cardiology and the European Respiratory Society (ESC-ERS) guidelines specify its role

  1. Detection of the origin of the cystic artery during transcatheter arterial embolization of hepatocellular carcinomas. Comparison of cone beam CT and digital subtraction angiography

    International Nuclear Information System (INIS)

    Hashizume, Takashi; Honda, Minoru; Seino, Noritaka; Gokan, Takehiko; Hashimoto, Toshi

    2009-01-01

    In this study, we retrospectively compared the usefulness of cone beam CT (CBCT) with that of digital subtraction angiography (DSA) in the identification of the origin of the cystic artery during arterial embolization for hepatocellular carcinoma. Subjects were sixty-four patients who underwent transcatheter arterial embolization (TAE) for hepatocellular carcinoma, in whom both CBCT and DSA were performed. Two radiologists independently examined CBCT and DSA images, and attempted to identify the origin of the cystic artery in each image. For DSA, en face views were reviewed on the monitor. For CBCT, 5 mm thick horizontal sections were generated using Workstation software, and the MPR (multi-planner reconstruction) method was used for coronary sections. These were then investigated with OsiriX. Of the sixty-four patients, the cystic arterial origin could be identified using DSA in 21 (32.8%) and CBCT in 62 (96.8%). The cystic artery was shown to originate in the proper, right, middle, and left hepatic artery in one, 58, two, and one patient, respectively. These results show that CBCT was more useful than DSA for identifying cystic arterial origin. Therefore CBCT should be positively applied during TAE. (author)

  2. Students’ Critical Mathematical Thinking Skills and Character:Experiments for Junior High School Students through Realistic Mathematics Education Culture-Based

    Directory of Open Access Journals (Sweden)

    Anderson L. Palinussa

    2013-01-01

    Full Text Available This paper presents the findings of a quasi-experimental with pre-test-post-test design and control group that aims to assess students’ critical mathematical thinking skills and character through realistic mathematics education (RME culture-based. Subjects of this study were 106 junior high school students from two low and medium schools level in Ambon. The instruments of the study are: students’ early math skills test, critical thinking skills mathematical test and perception scale of students’character. Data was analyzed by using t-test and Anova. The study found that: 1 Achievements and enhancement of students’ critical mathematical thinking skills who were treated with by realistic mathematics education is better then students’ skills were treated by conventional mathematics education. The differences are considered to: a overall students, b the level of early math skills, and c schools’ level; 2 Quality of students’ character who were treated by realistic mathematics education is better then students’ character who were treated by conventional mathematics education The differences are considered to: a overall students, b the level of early math skills, and c schools’ level  Keywords: Critical Thinking, Students’ Character, Realistic Mathematics Education Culture-Based DOI: http://dx.doi.org/10.22342/jme.4.1.566.75-94

  3. A Simple, Realistic Stochastic Model of Gastric Emptying.

    Directory of Open Access Journals (Sweden)

    Jiraphat Yokrattanasak

    Full Text Available Several models of Gastric Emptying (GE have been employed in the past to represent the rate of delivery of stomach contents to the duodenum and jejunum. These models have all used a deterministic form (algebraic equations or ordinary differential equations, considering GE as a continuous, smooth process in time. However, GE is known to occur as a sequence of spurts, irregular both in size and in timing. Hence, we formulate a simple stochastic process model, able to represent the irregular decrements of gastric contents after a meal. The model is calibrated on existing literature data and provides consistent predictions of the observed variability in the emptying trajectories. This approach may be useful in metabolic modeling, since it describes well and explains the apparently heterogeneous GE experimental results in situations where common gastric mechanics across subjects would be expected.

  4. Gender-related difference in arterial elastance during exercise in patients with hypertension.

    Science.gov (United States)

    Park, Sungha; Ha, Jong-Won; Shim, Chi Young; Choi, Eui-Young; Kim, Jin-Mi; Ahn, Jeong-Ah; Lee, Se-Wha; Rim, Se-Joong; Chung, Namsik

    2008-04-01

    Exercise intolerance and heart failure with preserved ejection fraction are common in females. Recently, arterial stiffness has been suggested to be a significant contributor in the development of heart failure. How gender difference affects arterial stiffening and its response to exercise is not well known. We hypothesized that arterial elastance index during exercise would be more abnormal in females with hypertension than males. Arterial elastance index was estimated as arterial end systolic pressure/stroke volume controlled for body surface area and was measured at rest and during graded supine bicycle exercise (25 watts, 3-minute increments) in 298 patients with hypertension (149 males; 149 females; mean age, 59). The subjects were divided into 2 groups by gender. Exercise duration was significantly shorter in females compared to males (692+/-222 versus 483+/-128 seconds, Pexercise being significantly higher in females compared to males (0.69+/-0.83 versus 0.43+/-0.69, P=0.018). Arterial elastance index at each stage of exercise up to 75 W was independently associated with decreased exercise duration. In conclusion, despite lower arterial elastance index at rest, the increase during exercise was steeper in women with hypertension, suggesting a gender-related difference in dynamic arterial stiffness. The arterial elastance index during exercise was significantly associated with exercise duration in patients with hypertension.

  5. Clinical evaluation of preoperative arterial infusion chemotherapy and surgical operation for colorectal carcinoma

    International Nuclear Information System (INIS)

    Yuan Jianhua; Zhao Zhongsheng; Deng Gaoli; Hu Tingyang; Yu Wenqiang; Chen Fanghong; Luo Zuyan; Ru Guoqing; Dong Quanjin; Tu Shiliang

    2003-01-01

    Objective: To investigate the clinical values of preoperative arterial infusion chemotherapy and surgical operation for colorectal carcinoma. Methods: 66 patients with colorectal carcinoma were subjected to percutaneous femoral artery catheterization by Seldinger's technique with infusion of anti-cancer drugs. The resection was performed 5-30 days after the arterial infusion (mean 12 days). In 50 surgical specimens of the 66 cases, histological findings were evaluated including the density and distribution of the apoptosis cells under the observation by DNA nick end labelling technique. Of which 22 specimens before arterial infusion chemotherapy (got from biopsy of preoperation) and 25 normal mucosa (got from normal surgical specimens) were used as controls. Results: The total histological response rate was 100% with grade I in 20 cases, grade II in 21 cases, grade III in 9 cases. The densities of the apoptosis cells were 31.47 ± 5.58 before arterial infusion chemotherapy, 76.69 ± 17.12 after arterial infusion chemotherapy and 8.01 ± 3.39 in normal mucosa. The density of the apoptosis cells after arterial infusion chemotherapy was significantly higher than that before arterial infusion chemotherapy (P 2 =4.696, P>0.30). There were no significant differences in the apoptosis of adenocarcinoma during different pathological stages (F=0.001376, P>0.05). Conclusions: Peroperative transcatheter arterial infusion chemotherapy resulting in apoptosis of adenocarcinoma, can raise the radical operation rate, and prolong survival rate for colorectal carcinoma patients

  6. Congenital anomalies of coronary arteries: Diagnosis with 64 slice multidetector CT

    Energy Technology Data Exchange (ETDEWEB)

    Tariq, Rukhsana, E-mail: drrukhsanatariq@hotmail.com [Consultant Radiologists, Advanced Radiology Clinic, Behind Hamdard University Hospital, Off M.A. Jinnah Road, Karachi (Pakistan); Kureshi, Shahzad Babar [Consultant Radiologists, Advanced Radiology Clinic, Behind Hamdard University Hospital, Off M.A. Jinnah Road, Karachi (Pakistan); Siddiqui, Usman T. [Medical College, Aga Khan University, Karachi (Pakistan); Ahmed, Rashid [Consultant Radiologists, Advanced Radiology Clinic, Behind Hamdard University Hospital, Off M.A. Jinnah Road, Karachi (Pakistan)

    2012-08-15

    Objective: Congenital coronary artery anomalies are generally incidental, uncommon and asymptomatic. Some can cause severe potentially life threatening symptoms. The common mode of studying the coronary arteries is Conventional Coronary Angiogram. ECG-gated-multidetector CT is a non invasive modality. The objective of our study was to identify rare congenital coronary artery anomalies and discuss their clinical significance. Material and methods: A total number of 900 MDCT coronary angiograms were carried out at our institution between the period of April 2006 and October 2010. Patients with coronary artery anomaly constituted the subject of study. Results: The incidence of anomalous anatomical origin and course of the coronary arteries in our study was 1.55%. Hemodynamical significance was seen in five patients. 3 cases of single coronary artery originating from right coronary sinus were seen. 1 case of anomalous left coronary artery arising from main pulmonary artery was seen. 4 cases of anomalous RCA arising from left aortic cusp, 6 cases of absent LMCA with separate origin of LAD and LCX were seen. Conclusion: Multidetector row CT is a noninvasive modality in cardiac imaging. It provides superior resolution of coronary tree and its variant. No projectional vascular overlap is seen. Various postprocessing techniques outclass catheter angiography imaging. Definition of ostia and proximal course of the coronary arteries by Multidetector CT is better than catheter angiography.

  7. Congenital anomalies of coronary arteries: Diagnosis with 64 slice multidetector CT

    International Nuclear Information System (INIS)

    Tariq, Rukhsana; Kureshi, Shahzad Babar; Siddiqui, Usman T.; Ahmed, Rashid

    2012-01-01

    Objective: Congenital coronary artery anomalies are generally incidental, uncommon and asymptomatic. Some can cause severe potentially life threatening symptoms. The common mode of studying the coronary arteries is Conventional Coronary Angiogram. ECG-gated-multidetector CT is a non invasive modality. The objective of our study was to identify rare congenital coronary artery anomalies and discuss their clinical significance. Material and methods: A total number of 900 MDCT coronary angiograms were carried out at our institution between the period of April 2006 and October 2010. Patients with coronary artery anomaly constituted the subject of study. Results: The incidence of anomalous anatomical origin and course of the coronary arteries in our study was 1.55%. Hemodynamical significance was seen in five patients. 3 cases of single coronary artery originating from right coronary sinus were seen. 1 case of anomalous left coronary artery arising from main pulmonary artery was seen. 4 cases of anomalous RCA arising from left aortic cusp, 6 cases of absent LMCA with separate origin of LAD and LCX were seen. Conclusion: Multidetector row CT is a noninvasive modality in cardiac imaging. It provides superior resolution of coronary tree and its variant. No projectional vascular overlap is seen. Various postprocessing techniques outclass catheter angiography imaging. Definition of ostia and proximal course of the coronary arteries by Multidetector CT is better than catheter angiography.

  8. Perceived synchrony for realistic and dynamic audiovisual events.

    Science.gov (United States)

    Eg, Ragnhild; Behne, Dawn M

    2015-01-01

    In well-controlled laboratory experiments, researchers have found that humans can perceive delays between auditory and visual signals as short as 20 ms. Conversely, other experiments have shown that humans can tolerate audiovisual asynchrony that exceeds 200 ms. This seeming contradiction in human temporal sensitivity can be attributed to a number of factors such as experimental approaches and precedence of the asynchronous signals, along with the nature, duration, location, complexity and repetitiveness of the audiovisual stimuli, and even individual differences. In order to better understand how temporal integration of audiovisual events occurs in the real world, we need to close the gap between the experimental setting and the complex setting of everyday life. With this work, we aimed to contribute one brick to the bridge that will close this gap. We compared perceived synchrony for long-running and eventful audiovisual sequences to shorter sequences that contain a single audiovisual event, for three types of content: action, music, and speech. The resulting windows of temporal integration showed that participants were better at detecting asynchrony for the longer stimuli, possibly because the long-running sequences contain multiple corresponding events that offer audiovisual timing cues. Moreover, the points of subjective simultaneity differ between content types, suggesting that the nature of a visual scene could influence the temporal perception of events. An expected outcome from this type of experiment was the rich variation among participants' distributions and the derived points of subjective simultaneity. Hence, the designs of similar experiments call for more participants than traditional psychophysical studies. Heeding this caution, we conclude that existing theories on multisensory perception are ready to be tested on more natural and representative stimuli.

  9. The Effect of Realistic Mathematics Education Approach on Students' Achievement And Attitudes Towards Mathematics

    Directory of Open Access Journals (Sweden)

    Effandi Zakaria

    2017-02-01

    Full Text Available This study was conducted to determine the effect of Realistic Mathematics Education Approach on mathematics achievement and student attitudes towards mathematics. This study also sought determine the relationship between student achievement and attitudes towards mathematics. This study used a quasi-experimental design conducted on 61 high school students at SMA Unggul Sigli. Students were divided into two groups, the treatment group $(n = 30$ namely, the Realistic Mathematics Approach group (PMR and the control group $(n = 31$ namely, the traditional group. This study was conducted for six weeks. The instruments used in this study were the achievement test and the attitudes towards mathematics questionnaires. Data were analyzed using SPSS. To determine the difference in mean achievement and attitudes between the two groups, data were analyzed using one-way ANOVA test. The result showed significant differences between the Realistic Mathematics Approach and the traditional approach in terms of achievement. The study showed no significant difference between the Realistic Mathematics Approach and the traditional approach in term of attitudes towards mathematics. It can be concluded that the use of realistic mathematics education approach enhanced students' mathematics achievement, but not attitudes towards mathematics. The Realistic Mathematics Education Approach encourage students to participate actively in the teaching and learning of mathematics. Thus, Realistic Mathematics Education Approach is an appropriate methods to improve the quality of teaching and learning process.

  10. [Arterial involvements in hereditary dysplasia of the connective tissue].

    Science.gov (United States)

    Beylot, C; Doutre, M S; Beylot-Barry, M; Busquet, M

    1994-03-01

    detailed in this paper constitute the main areas of this subject, but arterial involvement may occur in other inheritable disorders of connective tissue (osteogenesis imperfecta, cutis laxa, Werner syndrome, Menkes syndrome, etc).

  11. What Is Carotid Artery Disease?

    Science.gov (United States)

    ... Lack of physical activity . Too much sitting (sedentary lifestyle) and a lack of aerobic activity can worsen other risk factors for carotid artery disease, such as unhealthy blood cholesterol levels, high blood pressure, diabetes, and ...

  12. Coronary artery anatomy and variants

    Energy Technology Data Exchange (ETDEWEB)

    Malago, Roberto; Pezzato, Andrea; Barbiani, Camilla; Alfonsi, Ugolino; Nicoli, Lisa; Caliari, Giuliana; Pozzi Mucelli, Roberto [Policlinico G.B. Rossi, University of Verona, Department of Radiology, Verona (Italy)

    2011-12-15

    Variants and congenital anomalies of the coronary arteries are usually asymptomatic, but may present with severe chest pain or cardiac arrest. The introduction of multidetector CT coronary angiography (MDCT-CA) allows the detection of significant coronary artery stenosis. Improved performance with isotropic spatial resolution and higher temporal resolution provides a valid alternative to conventional coronary angiography (CCA) in many patients. MDCT-CA is now considered the ideal tool for three-dimensional visualization of the complex and tortuous anatomy of the coronary arteries. With multiplanar and volume-rendered reconstructions, MDCT-CA may even outperform CCA in determining the relative position of vessels, thus providing a better view of the coronary vascular anatomy. The purpose of this review is to describe the normal anatomy of the coronary arteries and their main variants based on MDCT-CA with appropriate reconstructions. (orig.)

  13. Sustainable Operation of Arterial Networks

    Science.gov (United States)

    2017-07-14

    This report describes operational data analysis and modeling of arterial networks with signalized intersections as follows: The setup for data collection, analysis and simulation is presented in Section 2.1. Detailed analysis of collected signal phas...

  14. Fibromuscular dysplasia of renal arteries

    International Nuclear Information System (INIS)

    Akhtar, N.; Ahmed, T.M.

    2007-01-01

    This case reports a young child having uncontrolled hypertension, resulting from bilateral renal artery stenosis due to fibromuscular dysplasia presenting with abdominal pain, headache and visual disturbance. Diagnostic features and management is discussed. (author)

  15. Venous thromboembolism and arterial complications.

    Science.gov (United States)

    Prandoni, Paolo; Piovella, Chiara; Pesavento, Raffaele

    2012-04-01

    An increasing body of evidence suggests the likelihood of a link between venous and arterial thrombosis. The two vascular complications share several risk factors, such as age, obesity, smoking, diabetes mellitus, blood hypertension, hypertriglyceridemia, and metabolic syndrome. Moreover, there are many examples of conditions accounting for both venous and arterial thrombosis, such as the antiphospholipid antibody syndrome, hyperhomocysteinemia, malignancies, infections, and the use of hormonal treatment. Finally, several recent studies have consistently shown that patients with venous thromboembolism are at a higher risk of arterial thrombotic complications than matched control individuals. We, therefore, speculate the two vascular complications are simultaneously triggered by biological stimuli responsible for activating coagulation and inflammatory pathways in both the arterial and the venous system. Future studies are needed to clarify the nature of this association, to assess its extent, and to evaluate its implications for clinical practice. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  16. Aberrant ovarian artery arising from the common Iliac artery: Case report

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Won Kyung [Dept. of Radiology, Soonchunhyang University Bucheon Hospital, Soonchunhyang University College of Medicine, Bucheon (Korea, Republic of); Yang, Seung Boo; Lee, Jae Myeong [Dept. of Radiology, Soonchunhyang University Gumi Hospital, Soonchunhyang University College of Medicine, Gumi (Korea, Republic of); Goo, Dong Erk; Kim, Yong Jae; Chang, Yun Woo [Dept. of Radiology, Soonchunhyang University Seoul Hospital, Soonchunhyang University College of Medicine, Seoul (Korea, Republic of)

    2013-01-15

    A 46-year-old Vietnamese woman received embolization therapy in order to control postpartum hemorrhage. Angiography revealed an aberrant ovarian artery arising from the right common iliac artery. Superselective catheterization and subsequent embolization of the aberrant ovarian artery and bilateral uterine arteries were performed. Precise knowledge of the anatomic variations of the ovarian artery is important for successful embolization.

  17. Aberrant ovarian artery arising from the common Iliac artery: Case report

    International Nuclear Information System (INIS)

    Kim, Won Kyung; Yang, Seung Boo; Lee, Jae Myeong; Goo, Dong Erk; Kim, Yong Jae; Chang, Yun Woo

    2013-01-01

    A 46-year-old Vietnamese woman received embolization therapy in order to control postpartum hemorrhage. Angiography revealed an aberrant ovarian artery arising from the right common iliac artery. Superselective catheterization and subsequent embolization of the aberrant ovarian artery and bilateral uterine arteries were performed. Precise knowledge of the anatomic variations of the ovarian artery is important for successful embolization.

  18. Heart transplantation and arterial elasticity

    Directory of Open Access Journals (Sweden)

    Colvin-Adams M

    2013-12-01

    Full Text Available Monica Colvin-Adams,1 Nonyelum Harcourt,1 Robert LeDuc,2 Ganesh Raveendran,1 Yassir Sonbol,3 Robert Wilson,1 Daniel Duprez11Cardiovascular Division, University of Minnesota, Minneapolis, MN, USA; 2Division of Biostatistics University of Minnesota, Minneapolis, MN, USA; 3Cardiovascular Division, St Luke's Hospital System, Sugar Land, TX, USAObjective: Arterial elasticity is a functional biomarker that has predictive value for cardiovascular morbidity and mortality in nontransplant populations. There is little information regarding arterial elasticity in heart transplant recipients. This study aimed to characterize small (SAE and large (LAE artery elasticity in heart transplant recipients in comparison with an asymptomatic population free of overt cardiovascular disease. A second goal was to identify demographic and clinical factors associated with arterial elasticity in this unique population.Methods: Arterial pulse waveform was registered noninvasively at the radial artery in 71 heart transplant recipients between 2008 and 2010. SAEs and LAEs were derived from diastolic pulse contour analysis. Comparisons were made to a healthy cohort of 1,808 participants selected from our prevention clinic database. Multiple regression analyses were performed to evaluate associations between risk factors and SAE and LAE within the heart transplant recipients.Results: LAE and SAE were significantly lower in heart transplant recipients than in the normal cohort (P <0.01 and P < 0.0001, respectively. Female sex and history of ischemic cardiomyopathy were significantly associated with reduced LAE and SAE. Older age and the presence of moderate cardiac allograft vasculopathy were also significantly associated with reduced SAE. Transplant duration was associated with increased SAE.Conclusion: Heart transplants are associated with peripheral endothelial dysfunction and arterial stiffness, as demonstrated by a significant reduction in SAE and LAE when compared with a

  19. Retinal vessel diameter and estimated cerebrospinal fluid pressure in arterial hypertension: the Beijing Eye Study.

    Science.gov (United States)

    Jonas, Jost B; Wang, Ningli; Wang, Shuang; Wang, Ya Xing; You, Qi Sheng; Yang, Diya; Wei, Wen Bin; Xu, Liang

    2014-09-01

    Hypertensive retinal microvascular abnormalities include an increased retinal vein-to-artery diameter ratio. Because central retinal vein pressure depends on cerebrospinal fluid pressure (CSFP), we examined whether the retinal vein-to-artery diameter ratio and other retinal hypertensive signs are associated with CSFP. Participants of the population-based Beijing Eye Study (n = 1,574 subjects) underwent measurement of the temporal inferior and superior retinal artery and vein diameter. CSFP was calculated as 0.44 × body mass index (kg/m(2)) + 0.16 × diastolic blood pressure (mm Hg) - 0.18 × age (years) - 1.91. Larger retinal vein diameters and higher vein-to-artery diameter ratios were significantly associated with higher estimated CSFP (P = 0.001) in multivariable analysis. In contrast, temporal inferior retinal arterial diameter was marginally associated (P = 0.03) with estimated CSFP, and temporal superior artery diameter was not significantly associated (P = 0.10) with estimated CSFP; other microvascular abnormalities, such as arteriovenous crossing signs, were also not significantly associated with estimated CSFP. In a reverse manner, higher estimated CSFP as a dependent variable in the multivariable analysis was associated with wider retinal veins and higher vein-to-artery diameter ratio. In the same model, estimated CSFP was not significantly correlated with retinal artery diameters or other retinal microvascular abnormalities. Correspondingly, arterial hypertension was associated with retinal microvascular abnormalities such as arteriovenous crossing signs (P = 0.003), thinner temporal retinal arteries (P arterial hypertension, an increased retinal vein-to-artery diameter ratio depends on elevated CSFP, which is correlated with blood pressure. © American Journal of Hypertension, Ltd 2014. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  20. Spontaneous indices are inconsistent with arterial baroreflex gain.

    Science.gov (United States)

    Lipman, Ruth D; Salisbury, Julie K; Taylor, J Andrew

    2003-10-01

    Spontaneously occurring, parallel fluctuations in arterial pressure and heart period are frequently used as indices of baroreflex function. Despite the convenience of spontaneous indices, their relation to the arterial baroreflex remains unclear. Therefore, in 97 volunteers, we derived 5 proposed indices (sequence method, alpha-index, transfer function, low-frequency transfer function, and impulse response function), compared them with arterial baroreflex gain (by the modified Oxford pharmacologic technique), and examined their relation to carotid distensibility and respiratory sinus arrhythmia. The subjects comprised men and women (n=41) aged 25 to 86 years, 30% of whom had established coronary artery disease. Generally, the indices were correlated with each other (except alpha-index and low-frequency transfer function) and with baroreflex gain. However, the Bland-Altman method demonstrated that the spontaneous indices had limits of agreement as large as the baroreflex gain itself. Even in individuals within the lowest tertile of baroreflex gain for whom baroreflex gain appears to be the most clinically relevant, spontaneous indices failed to relate to baroreflex gain. In fact, for these individuals, there was no correlation between any index and baroreflex gain. Forward stepwise linear regression showed that all spontaneous indices and baroreflex gain were related to respiratory sinus arrhythmia, but only baroreflex gain was related to carotid distensibility. Therefore, these data suggest that spontaneous indices are inadequate estimates of gain and are inconsistent with arterial baroreflex function.