  1. Neutron detection gamma ray sensitivity criteria

    International Nuclear Information System (INIS)

    Kouzes, Richard T.; Ely, James H.; Lintereur, Azaree T.; Mace, Emily K.; Stephens, Daniel L.; Woodring, Mitchell L.

    2011-01-01

    The shortage of 3 He has triggered the search for effective alternative neutron detection technologies for national security and safeguards applications. Any new detection technology must satisfy two basic criteria: (1) it must meet a neutron detection efficiency requirement, and (2) it must be insensitive to gamma-ray interference at a prescribed level, while still meeting the neutron detection requirement. It is the purpose of this paper to define measureable gamma ray sensitivity criteria for neutron detectors. Quantitative requirements are specified for: intrinsic gamma ray detection efficiency and gamma ray absolute rejection. The gamma absolute rejection ratio for neutrons (GARRn) is defined, and it is proposed that the requirement for neutron detection be 0.9 3 He based neutron detector is provided showing that this technology can meet the stated requirements. Results from tests of some alternative technologies are also reported.

  2. Quality criteria for chest X-ray image

    International Nuclear Information System (INIS)

    Krieg, R.

    1985-01-01

    A distinction has to be made between invariable and variable criteria in the determination of chest X-ray picture quality criteria. The invariable criteria are defined by the properties of the object and the psychophysiological laws of perception and cognition, and the variable criteria are determined by the prevailing state of the art of technology. An agreement on these criteria is based on the knowledge of the nature and the technical conditions of X-ray picture production and reproduction. The slogan 'the best picture at the lowest dose' dominates, too, the discussion centering around the X-ray picture of the chest, its quality and criteria. (orig./MG) [de

  3. Design criteria for small coded aperture masks in gamma-ray astronomy

    International Nuclear Information System (INIS)

    Sembay, S.; Gehrels, N.

    1990-01-01

    Most theoretical work on coded aperture masks in X-ray and low-energy γ-ray astronomy has concentrated on masks with large numbers of elements. For γ-ray spectrometers in the MeV range, the detector plane usually has only a few discrete elements, so that masks with small numbers of elements are called for. For this case it is feasible to analyse by computer all the possible mask patterns of given dimension to find the ones that best satisfy the desired performance criteria. In this paper we develop a particular set of performance criteria for comparing the flux sensitivities, source positioning accuracies and transparencies of different mask patterns. We then present the results of such a computer analysis for masks up to dimension 5x5 unit cell and conclude that there is a great deal of flexibility in one's choice of mask pattern for each dimension. (orig.)

  4. Ultimate detection sensitivity of Ge-Li γ-ray spectrometers

    International Nuclear Information System (INIS)

    1978-06-01

    This paper presents the principal results of a study concerning low-level counting capabilities of GeLi gamma-ray spectrometers. The expression adopted for the theoretical sensitivity limit of gamma spectrometers has been experimentally verified with very low activity samples, using 17 installations of various characteristics. This expression sets off the influence of the efficiency, the environmental conditions on the sensitivity limits. It can be used also to eliminate the fraudulents peaks in automatical analysis of gamma-ray spectras. At last, it provides a list of criteria to determine the most suitable characteristics of a detector according to a special problem. Informations which have to be obtained from the manufacturers are specified [fr

  5. The selection criteria elements of X-ray optics system

    Science.gov (United States)

    Plotnikova, I. V.; Chicherina, N. V.; Bays, S. S.; Bildanov, R. G.; Stary, O.

    2018-01-01

    At the design of new modifications of x-ray tomography there are difficulties in the right choice of elements of X-ray optical system. Now this problem is solved by practical consideration, selection of values of the corresponding parameters - tension on an x-ray tube taking into account the thickness and type of the studied material. For reduction of time and labor input of design it is necessary to create the criteria of the choice, to determine key parameters and characteristics of elements. In the article two main elements of X-ray optical system - an x-ray tube and the detector of x-ray radiation - are considered. Criteria of the choice of elements, their key characteristics, the main dependences of parameters, quality indicators and also recommendations according to the choice of elements of x-ray systems are received.

  6. IMRT QA: Selecting gamma criteria based on error detection sensitivity

    Energy Technology Data Exchange (ETDEWEB)

    Steers, Jennifer M. [Department of Radiation Oncology, Cedars-Sinai Medical Center, Los Angeles, California 90048 and Physics and Biology in Medicine IDP, David Geffen School of Medicine, University of California, Los Angeles, Los Angeles, California 90095 (United States); Fraass, Benedick A., E-mail: benedick.fraass@cshs.org [Department of Radiation Oncology, Cedars-Sinai Medical Center, Los Angeles, California 90048 (United States)

    2016-04-15

    Purpose: The gamma comparison is widely used to evaluate the agreement between measurements and treatment planning system calculations in patient-specific intensity modulated radiation therapy (IMRT) quality assurance (QA). However, recent publications have raised concerns about the lack of sensitivity when employing commonly used gamma criteria. Understanding the actual sensitivity of a wide range of different gamma criteria may allow the definition of more meaningful gamma criteria and tolerance limits in IMRT QA. We present a method that allows the quantitative determination of gamma criteria sensitivity to induced errors which can be applied to any unique combination of device, delivery technique, and software utilized in a specific clinic. Methods: A total of 21 DMLC IMRT QA measurements (ArcCHECK®, Sun Nuclear) were compared to QA plan calculations with induced errors. Three scenarios were studied: MU errors, multi-leaf collimator (MLC) errors, and the sensitivity of the gamma comparison to changes in penumbra width. Gamma comparisons were performed between measurements and error-induced calculations using a wide range of gamma criteria, resulting in a total of over 20 000 gamma comparisons. Gamma passing rates for each error class and case were graphed against error magnitude to create error curves in order to represent the range of missed errors in routine IMRT QA using 36 different gamma criteria. Results: This study demonstrates that systematic errors and case-specific errors can be detected by the error curve analysis. Depending on the location of the error curve peak (e.g., not centered about zero), 3%/3 mm threshold = 10% at 90% pixels passing may miss errors as large as 15% MU errors and ±1 cm random MLC errors for some cases. As the dose threshold parameter was increased for a given %Diff/distance-to-agreement (DTA) setting, error sensitivity was increased by up to a factor of two for select cases. This increased sensitivity with increasing dose

  7. Gamma ray sensitivity of superheated liquid

    International Nuclear Information System (INIS)

    Sawamura, Teruko; Sugiyama, Noriyuki; Narita, Masakuni

    2000-01-01

    The superheated drop detector (SDD) is composed of droplets of sensitive liquid with a low-boiling point and a medium supporting the dispersed droplets throughout the medium. The SDD has been mainly used for neutron dosimetry and recently also for gamma-rays. While for neutrons the conditions for bubble formation have been discussed, there has been little work for gamma-rays. We investigated the conditions for low LET radiation, such as protons and gamma-rays, and showed octafluoropropane (C 3 F 8 , boiling point -36.7degC) as advantageous liquid. The bubble formation condition is given by the energy density imparted from the charged particle to the sensitive liquid. The energy density requirement means that the energy must be deposited over a definite region length, effective to produce the vapor nucleus that becomes the visible bubble. Recently for γ-rays, Evans and Wang proposed the model that the vaporization was triggered by the energy deposition in a 'cluster' including many events in proximity in a superheated liquid. Measurements of the γ-ray sensitivity have not been sufficiently carried out and therefore the effective length or the cluster model has not been well-established. In this study the detection sensitivity was evaluated by measuring the life time of a liquid drop exposed to γ-rays. We developed a device trapping a superheated drop, where a single drop of test liquid was trapped and decompressed by an acoustic standing wave field. When a liquid drop with volume V[cm 3 ] is exposed to a γ-ray flux φ γ [cm -2 s -1 ], the average evaporation rate λ(T, P) [s -1 ] (T: temperature, P: decompressed pressure) is expressed as λ(T, P)=K γ Vφ γ (1), K γ [cm -1 ] is the γ-ray detection sensitivity per unit volume of the sensitive liquid and unit fluence. If the average rate of spontaneous evaporation is λ 0 (T, P), then the probability distribution of the life time t, the probability that t > τ, is expressed by X(τ)=exp{-(λ+λ 0 )

  8. Sensitivity of Gamma-Ray Detectors to Polarization

    OpenAIRE

    Yadigaroglu, I. -A.

    1996-01-01

    Previous studies have shown that the largest gamma-ray detector to date, EGRET, does not have useful polarization sensitivity. We have explored here some improved approaches to analyzing gamma-ray pair production events, leading to important gains in sensitivity to polarization. The performance of the next generation gamma-ray instrument GLAST is investigated using a detailed Monte Carlo simulation of the complete detector.

  9. Characterization of mutants of yeast sensitive to x rays

    International Nuclear Information System (INIS)

    Strike, T.L.

    1978-01-01

    This study deals with the characterization of mutants at the rad50 to rad57 loci selected on the basis of their sensitivity to x rays. They were also examined for sensitivity to uv and mms and for characteristics of mutation induction, heteroallelic reversion (gene conversion), liquid holding recovery from x rays, and sporulation. All the mutants were slightly to moderately sensitive to uv though they did not show the extreme sensitivity of the rad1 to rad22 mutations, and all demonstrated cross sensitivity to both x rays and MMS. If a mutant was very sensitive to x-rays, it was usually very sensitive to MMS also

  10. Charge collection and absorption-limited x-ray sensitivity of pixellated x-ray detectors

    International Nuclear Information System (INIS)

    Kabir, M. Zahangir; Kasap, S.O.

    2004-01-01

    The charge collection and absorption-limited x-ray sensitivity of a direct conversion pixellated x-ray detector operating in the presence of deep trapping of charge carriers is calculated using the Shockley-Ramo theorem and the weighting potential of the individual pixel. The sensitivity of a pixellated x-ray detector is analyzed in terms of normalized parameters; (a) the normalized x-ray absorption depth (absorption depth/photoconductor thickness), (b) normalized pixel width (pixel size/thickness), and (c) normalized carrier schubwegs (schubweg/thickness). The charge collection and absorption-limited sensitivity of pixellated x-ray detectors mainly depends on the transport properties (mobility and lifetime) of the charges that move towards the pixel electrodes and the extent of dependence increases with decreasing normalized pixel width. The x-ray sensitivity of smaller pixels may be higher or lower than that of larger pixels depending on the rate of electron and hole trapping and the bias polarity. The sensitivity of pixellated detectors can be improved by ensuring that the carrier with the higher mobility-lifetime product is drifted towards the pixel electrodes

  11. Sensitivity to ehter anasthesia and to γ-rays in mutagen-sensitive strains of Drosophila melanogaster

    International Nuclear Information System (INIS)

    Gamo, Sumiko; Nakashima-Tanaka, Eiji; Megumi, Tsuneo

    1990-01-01

    An ether-resistant strain of Drosophila melanogaster, Eth-29, has previously been found to be radiosensitive. Some mutagen-sensitive strains are known to be hypersensitive to X-rays in larvae. The correlation between sensitivities to ether anesthesia and to γ-rays was examined in adult flies of 12 mutagen-sensitive strains and 6 control strains. A wide variation in sensitivities to ether anesthesia, γ-ray knock-down and γ-ray lethality was demonstrated. No correlation between DNA-repaor capacity and ether sensitivity or γ-ray knock-down sensitivity was shown. Only mei-9 and mus201, which are deficient in excision repair, as well as Eth-29 were found to be sensitive to γ-ray lethality. These findings indicate that the targets for ehter anesthesia, knock-down and lethality may be different. Lethality appears to be caused by DNA damage, while the othe 2 endpoints appear not to be related to DNA damage. (author). 14 refs.; 3 tabs

  12. Geriatric-specific triage criteria are more sensitive than standard adult criteria in identifying need for trauma center care in injured older adults.

    Science.gov (United States)

    Ichwan, Brian; Darbha, Subrahmanyam; Shah, Manish N; Thompson, Laura; Evans, David C; Boulger, Creagh T; Caterino, Jeffrey M

    2015-01-01

    We evaluate the sensitivity of Ohio's 2009 emergency medical services (EMS) geriatric trauma triage criteria compared with the previous adult triage criteria in identifying need for trauma center care among older adults. We studied a retrospective cohort of injured patients aged 16 years or older in the 2006 to 2011 Ohio Trauma Registry. Patients aged 70 years or older were considered geriatric. We identified whether each patient met the geriatric and the adult triage criteria. The outcome measure was need for trauma center care, defined by surrogate markers: Injury Severity Score greater than 15, operating room in fewer than 48 hours, any ICU stay, and inhospital mortality. We calculated sensitivity and specificity of both triage criteria for both age groups. We included 101,577 patients; 33,379 (33%) were geriatric. Overall, 57% of patients met adult criteria and 68% met geriatric criteria. Using Injury Severity Score, for older adults geriatric criteria were more sensitive for need for trauma center care (93%; 95% confidence interval [CI] 92% to 93%) than adult criteria (61%; 95% CI 60% to 62%). Geriatric criteria decreased specificity in older adults from 61% (95% CI 61% to 62%) to 49% (95% CI 48% to 49%). Geriatric criteria in older adults (93% sensitivity, 49% specificity) performed similarly to the adult criteria in younger adults (sensitivity 87% and specificity 44%). Similar patterns were observed for other outcomes. Standard adult EMS triage guidelines provide poor sensitivity in older adults. Ohio's geriatric trauma triage guidelines significantly improve sensitivity in identifying Injury Severity Score and other surrogate markers of the need for trauma center care, with modest decreases in specificity for older adults. Copyright © 2014 American College of Emergency Physicians. Published by Elsevier Inc. All rights reserved.

  13. Position sensitive x-ray detector

    International Nuclear Information System (INIS)

    Macchione, E.L.A.

    1990-01-01

    A multi ware position sensitive gas counter for X-ray detection was developed in our laboratory, making use of commercial delay-lines for position sensing. Six delay-line chips (50 ns delay each, 40 Mhz cut-off frequency) cover a total sensitive length of 150 mm leading to a delay-risetime ratio that allows for a high-resolution position detection. Tests using the 5,9 keV X-ray line from a 55 Fe source and integral linearity better than 0,1% and a maximal differential linearity of ±4,0% were obtained operating the detector with an Ar-C H 4 (90%-10%) gas mixture at 700 torr. Similar tests were performed, using the 8,04 keV line from a Cu x-ray tube. A total resolution of 330 μm, and the same integral and differential linearities were obtained. (author)

  14. X-rays sensitive mammalian cell mutant

    International Nuclear Information System (INIS)

    Utsumi, Hiroshi

    1982-01-01

    A phenomenon that in x-ray-sensitive mammalian-cell mutants, cellular death due to x-ray radiation was not increased by caffeine, but on the contrary, the dead cells were resuscitated by it was discussed. The survival rate of mutant cells increased by caffein in a low concentration. This suggested that caffeine may have induced some mechanism to produce x-ray resistant mutant cells. Postirradiation treatment with caffeine increased considerably the survival rate of the mutant cells, and this suggested the existence of latent caffeine-sensitive potentially lethal damage repair system. This system, after a few hours, is thought to be substituted by caffeine-resistant repair system which is induced by caffeine, and this may be further substituted by x-ray-resistant repair system. The repair system was also induced by adenine. (Ueda, J.)

  15. X-ray sensitivity of somatic cell hybrids

    International Nuclear Information System (INIS)

    Zampetti-Bosseler, F.; Heilporn, V.; Lievens, A.; Limbosch, S.

    1976-01-01

    Different somatic cell hybrids have been studied as a function of their x-ray survival and karyotypic properties. Hybrids between x-ray-sensitive mouse lymphoma cells and mouse fibroblasts, retaining a large proportion of both parental chromosomes, were much more resistant to irradiation than either of the parental cells. On the other hand, hybrids between sensitive mouse lymphoma cells and hamster fibroblasts which also retained a relatively high number of chromosomes from both parents had a sensitivity intermediate between the sensitivities of the parental cell lines. Finally, hybrids between mouse fibroblasts and hamster fibroblasts carrying at least one hamster genome and less than one mouse genome resembled the hamster parent with respect to survival capactity. The significance of these results is discussed

  16. Position-sensitive X-ray detectors

    International Nuclear Information System (INIS)

    Hendrix, J.

    1982-01-01

    An overview is given of the different types of position-sensitive X-ray detectors used in kinetic studies of biological molecule state changes using X-ray diffraction with synchrotron radiation as a probe. The detector requirements and principles of operation of proportional counters are outlined. Multiwire proportional chamber systems and their readout techniques are described. Other detectors discussed include a drift chamber type detector, microchannel plates, charge-couple devices and, for high count rates, an integrating TV-detector. (U.K.)

  17. Gas position sensitive x-ray detectors

    International Nuclear Information System (INIS)

    Barbosa, A.F.

    1994-12-01

    The construction of gas x-ray detectors used to count and localize x-ray photons in one and two dimensions is reported. The principles of operation of the detectors are described, as well as the electronic modules comprised in the data acquisition system. Results obtained with detectors built at CBPF are shown, illustrating the performance of the Linear Position Sensitive Detectors. (author). 6 refs, 14 figs

  18. Prognostic criteria of sensitivity to antibiotics of staphylococcus clinical strains

    Directory of Open Access Journals (Sweden)

    Gordiy Paliy

    2015-06-01

    Department of Microbiology, Virology and Immunology, Vinnytsya National Pirogov Memorial Medical University Ministry of Health of Ukraine   Abstract In the article, the new data of sensitivity to antibiotics in clinical strains of Staphylococci are presented. For the first time, analytic dependence of dynamic prognostic criteria of the change of sensitivity of S. aureus clinical strains, isolated from patients, was obtained by means of mathematical prediction. There were investigated prognosticated indexes of Staphylococcus strains’ sensitivity to beta-lactams (oxacillin, ceftriaxone, imipenem and meropenem, vancomycin and linezolid. The dynamic of sensitivity decreasing to oxacillin, ceftriaxone, carbapenems (imipenem, meropenem, vancomycin (92,5 % and high sensitivity to linezolid in clinical strains of S. aureus were found out. Key words: sensitivity, antibiotics, Staphylococcus, prognostic indexes.

  19. The effect of liquid media on x-ray radiographic sensitivity

    International Nuclear Information System (INIS)

    Abdul Razak bin Daud; Ahmad Suhaimi bin Abdullah; Azali bin Muhamad

    1991-01-01

    The effect of liquid media i.e. tap water, seawater and crude oil on X-Rays radiographic sensitivity for 120, 160, 200 kV X-Rays was investigated. Stainless steel plates were used as specimens. Image quality indicators were German standard DIN 54109 - wire type and penetrameter ASME-SE142. Result obtained shows that radiographic sensitivity percents obtained in the liquid media using wire type image quality indicator and penetrameter are lessened to about 20-25% and 40-44% respectively with respect to radiographic sensitivity obtained in air. Optimum thickness of specimen for appropriate X-ray energies where sensitivity is best does not vary in air, tap water, seawater or crude oil

  20. Phase-space evolution of x-ray coherence in phase-sensitive imaging.

    Science.gov (United States)

    Wu, Xizeng; Liu, Hong

    2008-08-01

    X-ray coherence evolution in the imaging process plays a key role for x-ray phase-sensitive imaging. In this work we present a phase-space formulation for the phase-sensitive imaging. The theory is reformulated in terms of the cross-spectral density and associated Wigner distribution. The phase-space formulation enables an explicit and quantitative account of partial coherence effects on phase-sensitive imaging. The presented formulas for x-ray spectral density at the detector can be used for performing accurate phase retrieval and optimizing the phase-contrast visibility. The concept of phase-space shearing length derived from this phase-space formulation clarifies the spatial coherence requirement for phase-sensitive imaging with incoherent sources. The theory has been applied to x-ray Talbot interferometric imaging as well. The peak coherence condition derived reveals new insights into three-grating-based Talbot-interferometric imaging and gratings-based x-ray dark-field imaging.

  1. X-ray-sensitive mutants of Chinese hamster ovary cell line

    International Nuclear Information System (INIS)

    Jeggo, P.A.; Kemp, L.M.

    1983-01-01

    A standard technique of microbial genetics, which involves the transfer of cells from single colonies by means of sterile toothpicks, has been adapted to somatic cell genetics. Its use has been demonstrated in the isolation of X-ray-sensitive mutants of CHO cells. 9000 colonies have been tested and 6 appreciably X-ray-sensitive mutants were isolated. (D 10 values 5-10-fold of wild-type D 10 value.) A further 6 mutants were obtained which showed a slight level of sensitivity (D 10 values less than 2-fold of wild-type D 10 value). The 6 more sensitive mutants were also sensitive to bleomycin, a chemotherapeutic agent inducing X-ray-like damage. Cross-sensitivity to UV-irradiation and treatment with the alkylating agents, MMS, EMS and MNNG, was investigated for these mutants. Some sensitivity to these other agents was observed, but in all cases it was less severe than the level of sensitivity to X-irradiation. Each mutant showed a different overall response to the spectrum of agents examined and these appear to represent new mutant phenotypes derived from cultured mammalian cell lines. One mutant strain, xrs-7, was cross-sensitive to all the DNA-damaging agents, but was proficient in the repair of single-strand breaks. (Auth.)

  2. Position sensitive X-ray or X-ray detector and 3-D-tomography using same

    International Nuclear Information System (INIS)

    1975-01-01

    A fan-shaped beam of penetrating radiation, such as X-ray or γ-ray radiation, is directed through a slice of the body to be analyzed into a position sensitive detector for deriving a shadowgraph of transmission or absorption of the penetrating radiation by the body. A number of such shadowgraphs are obtained for different angles of rotation of the fan-shaped beam relative to the center of the slice being analyzed. The detected fan beam shadowgraph data is reordered into shadowgraph data corresponding to sets of parallel paths of radiation through the body. The reordered parallel path shadowgraph data is then convoluted in accordance with a 3-D reconstruction method by convolution in a computer to derive a 3-D reconstructed tomograph of the body under analysis. In a preferred embodiment, the position sensitive detector comprises a multiwire detector wherein the wires are arrayed parallel to the direction of the divergent penetrating rays to be detected. A focussed grid collimator is interposed between the body and the position sensitive detector for collimating the penetrating rays to be detected. The source of penetrating radiation is preferably a monochromatic source

  3. The color of X-rays: Spectral X-ray computed tomography using energy sensitive pixel detectors

    NARCIS (Netherlands)

    Schioppa, E.J.

    2014-01-01

    Energy sensitive X-ray imaging detectors are produced by connecting a semiconductor sensor to a spectroscopic pixel readout chip. In this thesis, the applicability of such detectors to X-ray Computed Tomography (CT) is studied. A prototype Medipix based silicon detector is calibrated using X-ray

  4. The γ rays sensitivity measurement of CeF3 scintillator detector

    International Nuclear Information System (INIS)

    Hu Mengchun; Zhou Dianzhong; Li Rurong; Wang Zhentong; Yang Hongqiong; Zhang Jianhua; Hu Qingyuan; Peng Taiping

    2003-01-01

    The CeF 3 is an abio-scintillator developed in recent years, which are insensitive to neutron and sensitive to gamma rays and respond quickness. The relationship of CeF 3 scintillation detector gamma rays sensitivity with the change of crystal thickness was measured. The CeF 3 scintillation detector is composed by high liner current photomultiplier tube of CHφT3, CHφT5 and CeF 3 scintillator. The detector gamma rays sensitivity of purple photocell and common photocell with CeF 3 scintillator were measured too

  5. Comparison of film sensitivity for sup(99m)Tc gamma-rays

    International Nuclear Information System (INIS)

    Kojima, Kazuhiko; Katayama, Masaharu; Hisada, Kinichi.

    1975-01-01

    Recently a new method of γ-ray imaging by holography has been studied at several nuclear medical laboratories. The holography is of a very simple. An axis Fresnel zone plate made of lead (2 mm thickness) is placed between the γ-ray source and a detector, and its shadow is recorded as a hologram. The hologram obtained is illuminated by parallel beams of He-Ne laser (6328 A), and an image of the radioisotope distribution in the object is reconstructed by diffraction. The better the resolution of the shadow hologram, the better are the reconstructed images obtained. For this reason the detector for recording the γ-ray hologram must be selected carefully. Three kinds of medical X-ray film were used as detectors for holograms to compare film sensitivity. Generally these medical X-ray films have poor sensitivity to γ-rays of sup(99m)Tc. In order to intensify the film sensitivity for γ-rays of sup(99m)Tc, combinations of six kinds of intensifying screens were studied. Good film sensitivity was obtained by RP (Kodak Co.) film combined with a KZ-S fluorescent intensifying screen. The fluorescent screen was better than fluorometallic screens with similar properties. Using this film-screen combination, shadow holograms could be recorded for 2-3 minutes and images could be optically reconstructed. (auth.)

  6. ASSESSMENT OF THE SENSITIVITY OF NEW CRITERIA FOR SYSTEMIC SCLEROSIS IN RUSSIAN PATIENT POPULATION

    Directory of Open Access Journals (Sweden)

    O. A. Koneva

    2015-01-01

    Full Text Available Systemic sclerosis (SS is a progressive connective tissue disease, the prognosis of which largely depends on the time of adequate therapy initiation. Low sensitivity of the 1980 American College of Rheumatology (ACR SS classification criteria for identifying patients with early stage of the disease, and with its limited form in particular, has necessitated revision of existing SS diagnostic standards and elaboration of more sensitive criteria that allow to establish the diagnosis when the first sign of the disease appear.Objective: to compare the sensitivity of the novel SS criteria of ACR and European League against Rheumatism (ACR/EULAR 2013 and the 1980 ACR criteria in different stages of the disease.Subjects and methods. The investigation enrolled 302 patients who had been diagnosed by experts as having SS and followed up at the V.A. Nasonova Research Institute of Rheumatology in 2007–2013. The patients’ mean age was 49±13 years (18 to 80 years; male to female ratio – 1:9 (31 and 271, that of patients with diffuse and limited SS – 1:2 (105 and 197; mean duration of the disease from the first non-Raynaud’s syndrome was 8.2±7.0 years (6 months to 36 years. Physical examination, nailfold capillaroscopy, chest radiography or computed tomography, echocardiography for the determination of pulmonary artery systolic pressure and SS-specific antibodies evaluation were performed.Results. 273 (90% patients fulfilled the novel ACR/EULAR 2013 SS criteria. 76 (25% patients had skin thickening above the metacarpophalangeal (MPC joints in both hands; 263 (87% – finger skin thickening [70 (23% – finger swelling, 192 (64% – thickening of all fingers distal to the MPC joints], 141 (47% – digital ischemia [79 (26% – digital pitting scars, 20 (7% – digital ulcers, 42 (14% – digital pitting scars and ulcers], 134 (44% – telangiectasias, 276 (91% – capillaroscopic changes, 225 (78% – pulmonary hypertension (PH or

  7. An X-ray gas position sensitive detector: construction and characterization

    International Nuclear Information System (INIS)

    Barbosa, A.F.; Gabriel, A.; Gabriel, A.; Craievich, A.

    1988-01-01

    A linear x-ray gas position sensitive detector with delay line readout has been constructed. The detector is described, characterized and used for detecting x-ray diffraction patterns from polycrystals. (author) [pt

  8. 3D elemental sensitive imaging using transmission X-ray microscopy.

    Science.gov (United States)

    Liu, Yijin; Meirer, Florian; Wang, Junyue; Requena, Guillermo; Williams, Phillip; Nelson, Johanna; Mehta, Apurva; Andrews, Joy C; Pianetta, Piero

    2012-09-01

    Determination of the heterogeneous distribution of metals in alloy/battery/catalyst and biological materials is critical to fully characterize and/or evaluate the functionality of the materials. Using synchrotron-based transmission x-ray microscopy (TXM), it is now feasible to perform nanoscale-resolution imaging over a wide X-ray energy range covering the absorption edges of many elements; combining elemental sensitive imaging with determination of sample morphology. We present an efficient and reliable methodology to perform 3D elemental sensitive imaging with excellent sample penetration (tens of microns) using hard X-ray TXM. A sample of an Al-Si piston alloy is used to demonstrate the capability of the proposed method.

  9. Sensitivity and specificity of proposed DSM-5 diagnostic criteria for autism spectrum disorder.

    Science.gov (United States)

    McPartland, James C; Reichow, Brian; Volkmar, Fred R

    2012-04-01

    This study evaluated the potential impact of proposed DSM-5 diagnostic criteria for autism spectrum disorder (ASD). The study focused on a sample of 933 participants evaluated during the DSM-IV field trial; 657 carried a clinical diagnosis of an ASD, and 276 were diagnosed with a non-autistic disorder. Sensitivity and specificity for proposed DSM-5 diagnostic criteria were evaluated using field trial symptom checklists as follows: individual field trial checklist items (e.g., nonverbal communication); checklist items grouped together as described by a single DSM-5 symptom (e.g., nonverbal and verbal communication); individual DSM-5 criterion (e.g., social-communicative impairment); and overall diagnostic criteria. When applying proposed DSM-5 diagnostic criteria for ASD, 60.6% (95% confidence interval: 57%-64%) of cases with a clinical diagnosis of an ASD met revised DSM-5 diagnostic criteria for ASD. Overall specificity was high, with 94.9% (95% confidence interval: 92%-97%) of individuals accurately excluded from the spectrum. Sensitivity varied by diagnostic subgroup (autistic disorder = 0.76; Asperger's disorder = 0.25; pervasive developmental disorder-not otherwise specified = 0.28) and cognitive ability (IQ criteria could substantially alter the composition of the autism spectrum. Revised criteria improve specificity but exclude a substantial portion of cognitively able individuals and those with ASDs other than autistic disorder. A more stringent diagnostic rubric holds significant public health ramifications regarding service eligibility and compatibility of historical and future research. Copyright © 2012 American Academy of Child and Adolescent Psychiatry. Published by Elsevier Inc. All rights reserved.

  10. A high resolution position sensitive X-ray MWPC for small angle X-ray diffraction

    International Nuclear Information System (INIS)

    Bateman, J.E.; Connolly, J.F.; Stephenson, R.; Tappern, G.J.

    1981-02-01

    A small sealed-off delay line readout MWPC X-ray detector has been designed and built for small angle X-ray diffraction applications. Featuring a sensitive area of 100 mm x 25 mm it yields a spatial resolution of 0.13 mm (standard deviation) with a high rate capability and good quantum efficiency for copper K radiation. (author)

  11. Criteria for a comparative assessment on handheld gamma-ray measurement tools

    International Nuclear Information System (INIS)

    Feichtinger, J.; Schwaiger, M.; Schmitzer, C.; Kindl, P.

    2001-01-01

    Full text: The radionuclide laboratories at the Austrian Research Centres Seibersdorf are strongly involved in radiation protection of public and employees as well as in environmental monitoring with special concern to gamma spectrometric measurements. Hence, field measurements and therefore the subject of hand-held measurement devices is a topic of main interest. Taking into consideration, that these hand-held measurement tool are further used in critical and sensitive operations, as for example by the IAEA Safeguards or by CTBTO On-Site inspectors, a standard for characterising these gamma measurement tools seems to be sound as necessary. The poster presents a set of technical criteria as well as limiting values, which allows an objective comparison of hand-held measurement devices. The criteria can be divided into three individual parts: radiometric characteristics, ergonomics and usability in field operations. The main criteria for testing the radiometry performance of hand-held measurement devices are sensitivity, efficiency, energy response, energy resolution and nuclide identification or not identification (if necessary), detection probability, dose rate indication, uncertainty, etc. The ergonomic test contains as dominating parts handling and quality of the manual. To evaluate the applicability in field operations different environmental conditions (e.g. light conditions, temperature range, moisture...) as well as battery lifetime and weight should be taken into account. These criteria may vary in dependence of the requirements or limitations given by various external conditions, but still a standard to evaluate and will give the opportunity to provide an objective comparison. (author)

  12. Sensitivity of the International Skating Union's Mathematical Criteria to Flag Potential Scoring Anomalies

    Science.gov (United States)

    Looney, Marilyn A.; Howell, Steven M.

    2015-01-01

    This article describes the "mathematical criteria" employed by the International Skating Union (ISU) to identify potential judging anomalies within competitive figure skating. The mathematical criteria have greater sensitivity to identify scoring anomalies for technical element scores than for the program component scores. This article…

  13. High sensitivity and specificity in proposed clinical diagnostic criteria for anti-N-methyl-D-aspartate receptor encephalitis.

    Science.gov (United States)

    Ho, Alvin C C; Mohammad, Shekeeb S; Pillai, Sekhar C; Tantsis, Esther; Jones, Hannah; Ho, Reena; Lim, Ming; Hacohen, Yael; Vincent, Angela; Dale, Russell C

    2017-12-01

    To determine the validity of the proposed clinical diagnostic criteria for anti-N-methyl-d-aspartate receptor (NMDAR) encephalitis in paediatric patients. The diagnostic criteria for anti-NMDAR encephalitis proposed by Graus et al. (2016) use clinical features and conventional investigations to facilitate early immunotherapy before antibody status is available. The criteria are satisfied if patients develop four out of six symptom groups within 3 months, together with at least one abnormal investigation (electroencephalography/cerebrospinal fluid) and reasonable exclusion of other disorders. We evaluated the validity of the criteria using a retrospective cohort of paediatric patients with encephalitis. Twenty-nine patients with anti-NMDAR encephalitis and 74 comparison children with encephalitis were included. As expected, the percentage of patients with anti-NMDAR encephalitis who fulfilled the clinical criteria increased over time. During the hospital inpatient admission, most patients (26/29, 90%) with anti-NMDAR encephalitis fulfilled the criteria, significantly more than the comparison group (3/74, 4%) (panti-NMDAR encephalitis was 2 weeks from first symptom onset (range 1-6). The sensitivity of the criteria was 90% (95% confidence interval 73-98) and the specificity was 96% (95% confidence interval 89-99). The proposed diagnostic criteria for anti-NMDAR encephalitis have good sensitivity and specificity. Incomplete criteria do not exclude the diagnosis. The proposed clinical diagnostic criteria for anti-N-methyl-d-aspartate receptor (NMDAR) encephalitis by Graus et al. (2016) have high sensitivity and specificity in paediatric patients. The median time of fulfilling the criteria in patients with anti-NMDAR was 2 weeks from first symptom onset. © 2017 Mac Keith Press.

  14. A highly sensitive x-ray imaging modality for hepatocellular carcinoma detection in vitro

    Science.gov (United States)

    Rand, Danielle; Walsh, Edward G.; Derdak, Zoltan; Wands, Jack R.; Rose-Petruck, Christoph

    2015-01-01

    Innovations that improve sensitivity and reduce cost are of paramount importance in diagnostic imaging. The novel x-ray imaging modality called spatial frequency heterodyne imaging (SFHI) is based on a linear arrangement of x-ray source, tissue, and x-ray detector, much like that of a conventional x-ray imaging apparatus. However, SFHI rests on a complete paradigm reversal compared to conventional x-ray absorption-based radiology: while scattered x-rays are carefully rejected in absorption-based x-ray radiology to enhance the image contrast, SFHI forms images exclusively from x-rays scattered by the tissue. In this study we use numerical processing to produce x-ray scatter images of hepatocellular carcinoma labeled with a nanoparticle contrast agent. We subsequently compare the sensitivity of SFHI in this application to that of both conventional x-ray imaging and magnetic resonance imaging (MRI). Although SFHI is still in the early stages of its development, our results show that the sensitivity of SFHI is an order of magnitude greater than that of absorption-based x-ray imaging and approximately equal to that of MRI. As x-ray imaging modalities typically have lower installation and service costs compared to MRI, SFHI could become a cost effective alternative to MRI, particularly in areas of the world with inadequate availability of MRI facilities.

  15. The X-ray sensitivity of semi-insulating polycrystalline CdZnTe thick films

    International Nuclear Information System (INIS)

    Won, Jae Ho; Kim, Ki Hyun; Suh, Jong Hee; Cho, Shin Hang; Cho, Pyong Kon; Hong, Jin Ki; Kim, Sun Ung

    2008-01-01

    The X-ray sensitivity is one of the important parameters indicating the detector performance. The X-ray sensitivity of semi-insulating polycrystalline CdZnTe:Cl thick films was investigated as a function of electric field, mean photon energy, film thickness, and charge carrier transport parameters and, compared with another promising detector materials. The X-ray sensitivities of the polycrystalline CdZnTe films with 350 μm thickness were about 2.2 and 6.2 μC/cm 2 /R in the ohmic-type and Schottky-type detector at 0.83 V/μm, respectively

  16. Sensitivity of P-Channel MOSFET to X- and Gamma-Ray Irradiation

    Directory of Open Access Journals (Sweden)

    Milić Pejović

    2013-01-01

    Full Text Available Investigation of Al-gate p-channel MOSFETs sensitivity following irradiation using 200 and 280 kV X-ray beams as well as gamma-ray irradiation of 60Co in the dose range from 1 to 5 Gy was performed in this paper. The response followed on the basis of threshold voltage shift and was studied as a function of absorbed dose. It was shown that the most significant change in threshold voltage was in the case of MOSFET irradiation in X-ray fields of 200 kV and when the gate voltage was +5 V. For practical applications in dosimetry, the sensitivity of the investigated MOSFETs was also satisfactory for X-ray tube voltage of 280 kV and for gamma rays. Possible processes in gate oxide caused by radiation and its impact on the response of MOSFETs were also analyzed in this paper.

  17. Isolation and cross-sensitivity of X-ray-sensitive mutants of V79-4 hamster cells

    International Nuclear Information System (INIS)

    Jones, N.J.; Cox, R.; Thacker, J.

    1987-01-01

    The V79-4 Chinese hamster line was mutagenized and surviving clones screened for X-ray sensitivity using a replica microwell technique. One slightly sensitive clone and 3 clearly sensitive clones were isolated from approximately 5000 screened, and designated irs 1 to irs 4. The 3 more sensitive clones showed different responses to the genotoxic agents mitomycin C (MMC), ethyl methanesulphonate (EMS) and ultraviolet light (UV). irs 1 showed considerable sensitivity to all the agents tested, in the order MMC >> EMS > UV. irs 2 and irs 3 had similar sensitivities to EMS and to UV (EMS > UV) but irs 3 was more sensitive than irs 2 to MMC. None of these mutants is identical in phenotype to previously published mutants. (Auth.)

  18. Measurements of reciprocity law failure in green-sensitive X-ray films.

    Science.gov (United States)

    Arnold, B A; Eisenberg, H; Bjärngard, B E

    1978-02-01

    Reciprocity law failure was measured for four brands of medical x-ray films exposed with intensifying screens. Three of the films are green light-sensitized for use in combination with green light-emitting rare-earth screens. These films showed larger reciprocity failure effects than one conventional blue-sensitive film, Dupont Cronex-2. Development conditions had a small effect on reciprocity failure. As part of the investigation, a detector was constructed with a response that accurately monitors the light emission from the double screen-cassette combination over a wide range of x-ray photon energies.

  19. Gamma ray polarimetry using a position sensitive germanium detector

    CERN Document Server

    Kroeger, R A; Kurfess, J D; Phlips, B F

    1999-01-01

    Imaging gamma-ray detectors make sensitive polarimeters in the Compton energy regime by measuring the scatter direction of gamma rays. The principle is to capitalize on the angular dependence of the Compton scattering cross section to polarized gamma rays and measure the distribution of scatter directions within the detector. This technique is effective in a double-sided germanium detector between roughly 50 keV and 1 MeV. This paper reviews device characteristics important to the optimization of a Compton polarimeter, and summarizes measurements we have made using a device with a 5x5 cm active area, 1 cm thickness, and strip-electrodes on a 2 mm pitch.

  20. X ray sensitive area detection device

    Science.gov (United States)

    Carter, Daniel C. (Inventor); Witherow, William K. (Inventor); Pusey, Marc L. (Inventor); Yost, Vaughn H. (Inventor)

    1990-01-01

    A radiation sensitive area detection device is disclosed which comprises a phosphor-containing film capable of receiving and storing an image formed by a pattern of incoming x rays, UV, or other radiation falling on the film. The device is capable of fluorescing in response to stimulation by a light source in a manner directly proportional to the stored radiation pattern. The device includes: (1) a light source capable of projecting light or other appropriate electromagnetic wave on the film so as to cause it to fluoresce; (2) a means to focus the fluoresced light coming from the phosphor-containing film after light stimulation; and (3) at least one charged coupled detector or other detecting element capable of receiving and digitizing the pattern of fluoresced light coming from the phosphor-containing film. The device will be able to generate superior x ray images of high resolution from a crystal or other sample and will be particularly advantageous in that instantaneous near-real-time images of rapidly deteriorating samples can be obtained. Furthermore, the device can be made compact and sturdy, thus capable of carrying out x ray or other radiation imaging under a variety of conditions, including those experienced in space.

  1. Calibration method of the pulsed X-ray relative sensitivity for ST401 plastic scintillators

    International Nuclear Information System (INIS)

    Xie Hongwei; Song Guzhou; Wang Kuilu

    2011-01-01

    The relative sensitivity calibration method of the pulsed X-ray in ST401 plastic scintillator is presented. Experimental relative sensitivity calibrations of the plastic scintillators of different thicknesses from 1 mm to 50 mm are accomplished on the 'Chenguang' pulsed X-ray source and a Co radioactive source, The uncertainty of the calibration data is evaluated, which can be treated as the experimental evidence for the relative sensitivity conversion of ST401 plastic scintillator. (authors)

  2. Spatial resolution in depth-controlled surface sensitive x-ray techniques

    International Nuclear Information System (INIS)

    Yun, W.B.; Viccaro, P.J.

    1992-01-01

    The spatial resolution along the surface normal and the total depth probed are two important parameters in depth-controlled surface sensitive X-ray techniques employing grazing incidence geometry. The two parameters are analyzed in terms of optical properties (refractive indices) of the media involved and parameters of the incident X-ray beam: beam divergence, X-ray energy, and spectral bandwidth. We derive analytical expressions of the required beam divergence and spectral bandwidth of the incident beam as a function of the two parameters. Sample calculations are made for X-ray energies between 0.1 and 100 keV and for solid Be, Cu, and Au, representing material matrices consisting of low, medium, and high atomic number elements. A brief discussion on obtaining the required beam divergence and spectral bandwidth from present X-ray sources and optics is given

  3. Sensitivity of performance assessment of the engineered barriers to nuances of release rate criteria

    International Nuclear Information System (INIS)

    Oliver, D.L.R.

    1987-01-01

    The United States Nuclear Regulatory Commission (NRC) has established criteria for the long-term performance of proposed high-level waste repositories. As with any regulation, the criteria may be interpreted in several ways. Due to the high capital costs and the emotional political climate associated with any high-level radioactive waste repository, it is important that there be an early consensus regarding interpretations of the criteria, and what assumptions may be used to demonstrate compliance with them. This work uses analytic solutions of mass transport theory to demonstrate how sensitive performance analyses are to various nuances of the NRC release rate criterion for the engineered barriers. The analysis is directed at the proposed repository in basalt at the Hanford site in Washington State

  4. Sensitivity and Specificity of Proposed "DSM-5" Diagnostic Criteria for Autism Spectrum Disorder

    Science.gov (United States)

    McPartland, James C.; Reichow, Brian; Volkmar, Fred R.

    2012-01-01

    Objective: This study evaluated the potential impact of proposed "DSM-5" diagnostic criteria for autism spectrum disorder (ASD). Method: The study focused on a sample of 933 participants evaluated during the "DSM-IV" field trial; 657 carried a clinical diagnosis of an ASD, and 276 were diagnosed with a non-autistic disorder. Sensitivity and…

  5. The color of X-rays Spectral X-ray computed tomography using energy sensitive pixel detectors

    CERN Document Server

    Schioppa, Enrico Junior

    Energy sensitive X-ray imaging detectors are produced by connecting a semiconductor sensor to a spectroscopic pixel readout chip. In this thesis, the applicability of such detectors to X-ray Computed Tomography (CT) is studied. A prototype Medipix based silicon detector is calibrated using X-ray fluorescence. The charge transport properties of the sensor are characterized using a high energy beam of charged particles at the Super Proton Synchrotron (SPS) at the European Center for Nuclear Research (CERN). Monochromatic X-rays at the European Synchrotron Radiation Facility (ESRF) are used to determined the energy response function. These data are used to implement a physics-based CT projection operator that accounts for the transmission of the source spectrum through the sample and detector effects. Based on this projection operator, an iterative spectral CT reconstruction algorithm is developed by extending an Ordered Subset Expectation Maximization (OSEM) method. Subsequently, a maximum likelihood based algo...

  6. The sensitizing phenomenon of X-ray film in the experiment of metals loaded with deuterium

    International Nuclear Information System (INIS)

    Chen Suhe; Wang Dalun; Chen Wenjang; Li Yijun; Fu Yibei; Zhang Xinwei

    1993-01-01

    The sensitizing phenomenon of X-ray film was studied, in metals loaded with deuterium, by a cycle method of temperature and pressure (CMTP). The experimental results showed that the sensitization of X-ray film was derived from the chemical reaction and the anomalous effect of metals loaded with deuterium. (author)

  7. Isolation of cell cycle-dependent gamma ray-sensitive Chinese hamster ovary cell

    International Nuclear Information System (INIS)

    Stamato, T.D.; Weinstein, R.; Giaccia, A.; Mackenzie, L.

    1983-01-01

    A technique for the isolation of gamma ray-sensitive Chinese hamster ovary (CHO) cell mutants is described, which uses nylon cloth replica plating and photography with dark-field illumination to directly monitor colonies for growth after gamma irradiation. Two gamma ray-sensitive mutants were isolated using this method. One of these cells (XR-1) had a two-slope survival curve: an initial steep slope and then a flattening of the curve at about 10% survival. Subsequently, it was found that this cell is sensitive to gamma irradiation in G1, early S, and late G2 phases of the cell cycle, whereas in the resistant phase (late S phase) its survival approaches that of the parental cells. The D37 in the sensitive G1 period is approximately 30 rads, compared with 300 rads of the parental cell. This mutant cell is also sensitive to killing by the DNA breaking agent, bleomycin, but is relatively insensitive to UV light and ethyl methane sulfonate, suggesting that the defect is specific for agents that produce DNA strand breakage

  8. Gamma ray induced sensitization in CaSO4:Dy and competing trap model

    International Nuclear Information System (INIS)

    Nagpal, J.S.; Kher, R.K.; Gangadharan, P.

    1979-01-01

    Gamma ray induced sensitization in CaSO 4 :Dy has been compared (by measurement of TL glow curves) for different temperatures during irradiation (25 0 , 120 0 and 250 0 C). Enhanced sensitization at elevated temperatures seems to support the competing trap model for supralinearity and sensitization in CaSO 4 :Dy. (author)

  9. Sensitivity of in vivo X-ray fluorescence determination of skeletal lead stores

    International Nuclear Information System (INIS)

    Sokas, R.K.; Besarab, A.; McDiarmid, M.A.; Shapiro, I.M.; Bloch, P.

    1990-01-01

    Eighteen patients with known past occupational lead exposure underwent parenteral diagnostic chelation with ethylenediaminetetraacetic acid and x-ray fluorescent determination of in vivo skeletal lead stores at the distal styloid process of the ulna and at the temporal base bone using a cobalt 57 source and measuring lead Ka x-rays. X-ray fluorescent lead measurements in both locations correlated with results of diagnostic chelation. Using a post-chelation urinary excretion of greater than 600 micrograms lead/24 h as the definition of high-lead stores, sensitivity of x-ray fluorescence at the wrist and temple was 56% and 39%, respectively

  10. Project Title: Radiochemical Analysis by High Sensitivity Dual-Optic Micro X-ray Fluorescence

    International Nuclear Information System (INIS)

    Havrilla, George J.; Gao, Ning

    2002-01-01

    A novel dual-optic micro X-ray fluorescence instrument will be developed to do radiochemical analysis of high-level radioactive wastes at DOE sites such as Savannah River Site and Hanford. This concept incorporates new X-ray optical elements such as monolithic polycapillaries and double bent crystals, which focus X-rays. The polycapillary optic can be used to focus X-rays emitted by the X-ray tube thereby increasing the X-ray flux on the sample over 1000 times. Polycapillaries will also be used to collect the X-rays from the excitation site and screen the radiation background from the radioactive species in the specimen. This dual-optic approach significantly reduces the background and increases the analyte signal thereby increasing the sensitivity of the analysis. A doubly bent crystal used as the focusing optic produces focused monochromatic X-ray excitation, which eliminates the bremsstrahlung background from the X-ray source. The coupling of the doubly bent crystal for monochromatic excitation with a polycapillary for signal collection can effectively eliminate the noise background and radiation background from the specimen. The integration of these X-ray optics increases the signal-to-noise and thereby increases the sensitivity of the analysis for low-level analytes. This work will address a key need for radiochemical analysis of high-level waste using a non-destructive, multi-element, and rapid method in a radiation environment. There is significant potential that this instrumentation could be capable of on-line analysis for process waste stream characterization at DOE sites

  11. Criteria for the prioritization of public health interventions for climate-sensitive vector-borne diseases in Quebec.

    Directory of Open Access Journals (Sweden)

    Valerie Hongoh

    Full Text Available Prioritizing resources for optimal responses to an ever growing list of existing and emerging infectious diseases represents an important challenge to public health. In the context of climate change, there is increasing anticipated variability in the occurrence of infectious diseases, notably climate-sensitive vector-borne diseases. An essential step in prioritizing efforts is to identify what considerations and concerns to take into account to guide decisions and thus set disease priorities. This study was designed to perform a comprehensive review of criteria for vector-borne disease prioritization, assess their applicability in a context of climate change with a diverse cross-section of stakeholders in order to produce a baseline list of considerations to use in this decision-making context. Differences in stakeholder choices were examined with regards to prioritization of these criteria for research, surveillance and disease prevention and control objectives. A preliminary list of criteria was identified following a review of the literature. Discussions with stakeholders were held to consolidate and validate this list of criteria and examine their effects on disease prioritization. After this validation phase, a total of 21 criteria were retained. A pilot vector-borne disease prioritization exercise was conducted using PROMETHEE to examine the effects of the retained criteria on prioritization in different intervention domains. Overall, concerns expressed by stakeholders for prioritization were well aligned with categories of criteria identified in previous prioritization studies. Weighting by category was consistent between stakeholders overall, though some significant differences were found between public health and non-public health stakeholders. From this exercise, a general model for climate-sensitive vector-borne disease prioritization has been developed that can be used as a starting point for further public health prioritization

  12. Criteria for the prioritization of public health interventions for climate-sensitive vector-borne diseases in Quebec.

    Science.gov (United States)

    Hongoh, Valerie; Gosselin, Pierre; Michel, Pascal; Ravel, André; Waaub, Jean-Philippe; Campagna, Céline; Samoura, Karim

    2017-01-01

    Prioritizing resources for optimal responses to an ever growing list of existing and emerging infectious diseases represents an important challenge to public health. In the context of climate change, there is increasing anticipated variability in the occurrence of infectious diseases, notably climate-sensitive vector-borne diseases. An essential step in prioritizing efforts is to identify what considerations and concerns to take into account to guide decisions and thus set disease priorities. This study was designed to perform a comprehensive review of criteria for vector-borne disease prioritization, assess their applicability in a context of climate change with a diverse cross-section of stakeholders in order to produce a baseline list of considerations to use in this decision-making context. Differences in stakeholder choices were examined with regards to prioritization of these criteria for research, surveillance and disease prevention and control objectives. A preliminary list of criteria was identified following a review of the literature. Discussions with stakeholders were held to consolidate and validate this list of criteria and examine their effects on disease prioritization. After this validation phase, a total of 21 criteria were retained. A pilot vector-borne disease prioritization exercise was conducted using PROMETHEE to examine the effects of the retained criteria on prioritization in different intervention domains. Overall, concerns expressed by stakeholders for prioritization were well aligned with categories of criteria identified in previous prioritization studies. Weighting by category was consistent between stakeholders overall, though some significant differences were found between public health and non-public health stakeholders. From this exercise, a general model for climate-sensitive vector-borne disease prioritization has been developed that can be used as a starting point for further public health prioritization exercises relating to

  13. Thermo-mechanical failure criteria for x-ray windows and filters and comparison with experiments

    International Nuclear Information System (INIS)

    Wang, Z.; Kuzay, T.M.

    1993-01-01

    Synchrotron x-ray windows are vacuum separators and are usually made of thin beryllium metal. Filters are provided upstream of the window to filter out the soft x-rays to protect the window from overheating and failing. The filters are made of thin carbon products or sometimes beryllium, the same material as the window. Because the window is a vacuum separator, understanding its potential structural failure under thermal load is very important. Current structural failure models for the brazed windows and filters under thermal stresses are not very accurate. Existing models have been carefully examined and found to be inconsistent with the actual failure modes of windows tested. Due to the thinness of the filter/window, the most likely failure mode is thermal buckling. In fact, recent synchrotron tests conducted in Japan on window failures bear out this position. In this paper, failure criteria for filters/windows are proposed, and analyses are performed and compared with the experimental results from various sources. A consistent result is found between the analysis and reported experiments. A series of additional analyses based on the proposed failure criteria is also carried out for filter and window designs for the third generation synchrotron beamline front ends. Comparative results are presented here

  14. A general technique for characterizing x-ray position sensitive arrays

    International Nuclear Information System (INIS)

    Dufresne, E.; Bruning, R.; Sutton, M.; Stephenson, G.B.

    1994-03-01

    We present a general statistical technique for characterizing x-ray sensitive linear diode arrays and CCD arrays. We apply this technique to characterize the response of a linear diode array, Princeton Instrument model X-PDA, and a virtual phase CCD array, TI 4849, to direct illumination by x-rays. We find that the response of the linear array is linearly proportional to the incident intensity and uniform over its length to within 2 %. Its quantum efficiency is 38 % for Cu K α x-rays. The resolution function is evaluated from the spatial autocorrelation function and falls to 10 % of its peak value after one pixel. On the other hand, the response of the CCD detecting system to direct x-ray exposure is non-linear. To properly quantify the scattered x-rays, one must correct for the non- linearity. The resolution is two pixels along the serial transfer direction. We characterize the noise of the CCD and propose a model that takes into account the non-linearity and the resolution function to estimate the quantum efficiency of the detector. The quantum efficiency is 20 %

  15. An unexpected caffeine-enhanced survival in x-ray-sensitive variant cells

    International Nuclear Information System (INIS)

    Utsumi, Hiroshi

    1985-01-01

    The sensitivity of normal Chinese hamster cell lines, V79 and CHO, mouse cell lines, L5178Y and L, and human HeLa cells to the killing effect of x-ray is enhanced with addition of caffeine following x-ray irradiation in a dose-dependent fashion. However, the survival rate of variant cell (V79-AL162/S-10) increased with addition of low concentration of caffeine (caffeine-enhanced survival phenomenon). Therefore, the effects of protein synthesis-inhibiting agents, such as cycloheximide and puromycin, on caffeine-enhanced survival phenomenon were examined. This phenomenon was completely abolished by the inhibitory agents, but not abolished by DNA synthesis-damaging agents, such as excess thymidine and aphidicolin. DNA-damaging physiochemical factors, such as neutrons, U.V., methyl methanesulfonate and mitomycin C, were examined in relation to variant cells' sensitivity and caffeine-enhanced survival phenomenon. V79-AL162/S-10 cells showed high sensitivity to the killing effect of mitomycin C, but their survival rate returned to the rate of normal V79-B310H cells with addition of caffeine. (Namekawa, K.)

  16. A two-dimensional analysis of the sensitivity of a pulse first break to wave speed contrast on a scale below the resolution length of ray tomography.

    Science.gov (United States)

    Willey, Carson L; Simonetti, Francesco

    2016-06-01

    Mapping the speed of mechanical waves traveling inside a medium is a topic of great interest across many fields from geoscience to medical diagnostics. Much work has been done to characterize the fidelity with which the geometrical features of the medium can be reconstructed and multiple resolution criteria have been proposed depending on the wave-matter interaction model used to decode the wave speed map from scattering measurements. However, these criteria do not define the accuracy with which the wave speed values can be reconstructed. Using two-dimensional simulations, it is shown that the first-arrival traveltime predicted by ray theory can be an accurate representation of the arrival of a pulse first break even in the presence of diffraction and other phenomena that are not accounted for by ray theory. As a result, ray-based tomographic inversions can yield accurate wave speed estimations also when the size of a sound speed anomaly is smaller than the resolution length of the inversion method provided that traveltimes are estimated from the signal first break. This increased sensitivity however renders the inversion more susceptible to noise since the amplitude of the signal around the first break is typically low especially when three-dimensional anomalies are considered.

  17. Polymer gel dosimeters with enhanced sensitivity for use in x-ray CT polymer gel dosimetry

    International Nuclear Information System (INIS)

    Jirasek, A; Hilts, M; McAuley, K B

    2010-01-01

    A primary limitation of current x-ray CT polymer gel dosimetry is the low contrast, and hence poor dose resolution, of dose images produced by the system. The low contrast is largely due to the low-dose sensitivity of current formulations of polymer gel for x-ray CT imaging. This study reports on the investigation of new dosimeter formulations with improved dose sensitivity for x-ray CT polymer gel dosimetry. We incorporate an isopropanol co-solvent into an N-isopropylacrylamide-based gel formulation in order to increase the total monomer/crosslinker concentration (%T) within the formulation. It is shown that gels of high %T exhibit enhanced dose sensitivity and dose resolutions over traditional formulations. The gels are shown to be temporally stable and reproducible. A single formulation (16%T) is used to demonstrate the capabilities of the x-ray CT polymer gel dosimetry system in measuring known dose distributions. A 1 L gel volume is exposed to three separate irradiations: a single-field percent depth dose, a two-field 'cross' and a three-field 'test case'. The first two irradiations are used to generate a dose calibration curve by which images are calibrated. The calibrated images are compared with treatment planning predictions and it is shown that the x-ray CT polymer gel dosimetry system is capable of capturing spatial and dose information accurately. The proposed new gel formulation is shown to be sensitive, stable and to improve the dose resolution over current formulations so as to provide a feasible gel for clinical applications of x-ray CT polymer gel dosimetry.

  18. Sensitivity of a search for cosmic ray sources including magnetic field effects

    Energy Technology Data Exchange (ETDEWEB)

    Urban, Martin; Erdmann, Martin; Mueller, Gero [III. Physikalisches Institut A, RWTH Aachen University (Germany)

    2016-07-01

    We analyze the sensitivity of a new method investigating correlations between ultra-high energy cosmic rays and extragalactic sources taking into account deflections in the galactic magnetic field. In comparisons of expected and simulated arrival directions of cosmic rays we evaluate the directional characteristics and magnitude of the field. We show that our method is capable of detecting anisotropy in data sets with a low signal fraction.

  19. X-ray-sensitive storage phosphors with the optically stable luminescent centres

    CERN Document Server

    Gorin, G B; Zvezdova, N P; Kochubey, D I; Sedova, Y G; Kochubey, D I; Kulipanov, G N; Lyakh, V V; Pindyurin, V F

    2000-01-01

    NaCl, KCl, KBr and LiF crystals doped by In, Tl, Ni, Pd and Ca were investigated as X-ray-sensitive materials. Influence of the way of doping of an impurity and growing of a crystal on such parameters of a material as: sensitivity to ionising radiation; radiative, optical and thermal stability of the image, obtained after an irradiation is investigated. As a result of the work, media for recording of the X-ray images are developed. These allow to reproduce the images in a mode of a photoluminescence. Spatial resolution and the dynamic range of registration of the developed materials concede to similar parameters of commercial storage luminophores like 'Image Plates' based on BaFBr : La. At the same time, as distinct from 'Image Plates', the developed radiophotoluminophores allow a long storage and multiple readout of the information recorded.

  20. Bulk sensitive hard x-ray photoemission electron microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Patt, M., E-mail: m.patt@fz-juelich.de; Wiemann, C. [Peter Grünberg Institute (PGI-6) and JARA-FIT, Research Center Jülich, D-52425 Jülich (Germany); Weber, N.; Escher, M.; Merkel, M. [Focus GmbH, Neukirchner Str. 2, D-65510 Hünstetten (Germany); Gloskovskii, A.; Drube, W. [DESY Photon Science, Deutsches Elektronen-Synchrotron, D-22603 Hamburg (Germany); Schneider, C. M. [Peter Grünberg Institute (PGI-6) and JARA-FIT, Research Center Jülich, D-52425 Jülich (Germany); Fakultät f. Physik and Center for Nanointegration Duisburg-Essen (CeNIDE), Universität Duisburg-Essen, D-47048 Duisburg (Germany)

    2014-11-15

    Hard x-ray photoelectron spectroscopy (HAXPES) has now matured into a well-established technique as a bulk sensitive probe of the electronic structure due to the larger escape depth of the highly energetic electrons. In order to enable HAXPES studies with high lateral resolution, we have set up a dedicated energy-filtered hard x-ray photoemission electron microscope (HAXPEEM) working with electron kinetic energies up to 10 keV. It is based on the NanoESCA design and also preserves the performance of the instrument in the low and medium energy range. In this way, spectromicroscopy can be performed from threshold to hard x-ray photoemission. The high potential of the HAXPEEM approach for the investigation of buried layers and structures has been shown already on a layered and structured SrTiO{sub 3} sample. Here, we present results of experiments with test structures to elaborate the imaging and spectroscopic performance of the instrument and show the capabilities of the method to image bulk properties. Additionally, we introduce a method to determine the effective attenuation length of photoelectrons in a direct photoemission experiment.

  1. Polymer gel dosimeters with enhanced sensitivity for use in x-ray CT polymer gel dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Jirasek, A [Department of Physics and Astronomy, University of Victoria, Victoria BC V8W 3P6 (Canada); Hilts, M [Medical Physics, BC Cancer Agency-Vancouver Island Centre, Victoria BC V6R 2B6 (Canada); McAuley, K B, E-mail: jirasek@uvic.c [Department of Chemical Engineering, Queens University, Kingston, ON K7 L 3N6 (Canada)

    2010-09-21

    A primary limitation of current x-ray CT polymer gel dosimetry is the low contrast, and hence poor dose resolution, of dose images produced by the system. The low contrast is largely due to the low-dose sensitivity of current formulations of polymer gel for x-ray CT imaging. This study reports on the investigation of new dosimeter formulations with improved dose sensitivity for x-ray CT polymer gel dosimetry. We incorporate an isopropanol co-solvent into an N-isopropylacrylamide-based gel formulation in order to increase the total monomer/crosslinker concentration (%T) within the formulation. It is shown that gels of high %T exhibit enhanced dose sensitivity and dose resolutions over traditional formulations. The gels are shown to be temporally stable and reproducible. A single formulation (16%T) is used to demonstrate the capabilities of the x-ray CT polymer gel dosimetry system in measuring known dose distributions. A 1 L gel volume is exposed to three separate irradiations: a single-field percent depth dose, a two-field 'cross' and a three-field 'test case'. The first two irradiations are used to generate a dose calibration curve by which images are calibrated. The calibrated images are compared with treatment planning predictions and it is shown that the x-ray CT polymer gel dosimetry system is capable of capturing spatial and dose information accurately. The proposed new gel formulation is shown to be sensitive, stable and to improve the dose resolution over current formulations so as to provide a feasible gel for clinical applications of x-ray CT polymer gel dosimetry.

  2. A GIS based spatially-explicit sensitivity and uncertainty analysis approach for multi-criteria decision analysis☆

    Science.gov (United States)

    Feizizadeh, Bakhtiar; Jankowski, Piotr; Blaschke, Thomas

    2014-01-01

    GIS multicriteria decision analysis (MCDA) techniques are increasingly used in landslide susceptibility mapping for the prediction of future hazards, land use planning, as well as for hazard preparedness. However, the uncertainties associated with MCDA techniques are inevitable and model outcomes are open to multiple types of uncertainty. In this paper, we present a systematic approach to uncertainty and sensitivity analysis. We access the uncertainty of landslide susceptibility maps produced with GIS-MCDA techniques. A new spatially-explicit approach and Dempster–Shafer Theory (DST) are employed to assess the uncertainties associated with two MCDA techniques, namely Analytical Hierarchical Process (AHP) and Ordered Weighted Averaging (OWA) implemented in GIS. The methodology is composed of three different phases. First, weights are computed to express the relative importance of factors (criteria) for landslide susceptibility. Next, the uncertainty and sensitivity of landslide susceptibility is analyzed as a function of weights using Monte Carlo Simulation and Global Sensitivity Analysis. Finally, the results are validated using a landslide inventory database and by applying DST. The comparisons of the obtained landslide susceptibility maps of both MCDA techniques with known landslides show that the AHP outperforms OWA. However, the OWA-generated landslide susceptibility map shows lower uncertainty than the AHP-generated map. The results demonstrate that further improvement in the accuracy of GIS-based MCDA can be achieved by employing an integrated uncertainty–sensitivity analysis approach, in which the uncertainty of landslide susceptibility model is decomposed and attributed to model's criteria weights. PMID:25843987

  3. A GIS based spatially-explicit sensitivity and uncertainty analysis approach for multi-criteria decision analysis.

    Science.gov (United States)

    Feizizadeh, Bakhtiar; Jankowski, Piotr; Blaschke, Thomas

    2014-03-01

    GIS multicriteria decision analysis (MCDA) techniques are increasingly used in landslide susceptibility mapping for the prediction of future hazards, land use planning, as well as for hazard preparedness. However, the uncertainties associated with MCDA techniques are inevitable and model outcomes are open to multiple types of uncertainty. In this paper, we present a systematic approach to uncertainty and sensitivity analysis. We access the uncertainty of landslide susceptibility maps produced with GIS-MCDA techniques. A new spatially-explicit approach and Dempster-Shafer Theory (DST) are employed to assess the uncertainties associated with two MCDA techniques, namely Analytical Hierarchical Process (AHP) and Ordered Weighted Averaging (OWA) implemented in GIS. The methodology is composed of three different phases. First, weights are computed to express the relative importance of factors (criteria) for landslide susceptibility. Next, the uncertainty and sensitivity of landslide susceptibility is analyzed as a function of weights using Monte Carlo Simulation and Global Sensitivity Analysis. Finally, the results are validated using a landslide inventory database and by applying DST. The comparisons of the obtained landslide susceptibility maps of both MCDA techniques with known landslides show that the AHP outperforms OWA. However, the OWA-generated landslide susceptibility map shows lower uncertainty than the AHP-generated map. The results demonstrate that further improvement in the accuracy of GIS-based MCDA can be achieved by employing an integrated uncertainty-sensitivity analysis approach, in which the uncertainty of landslide susceptibility model is decomposed and attributed to model's criteria weights.

  4. UV and gamma-ray sensitivity of meiosis-deficient mutants in Podospora anserina

    International Nuclear Information System (INIS)

    Simonet, J.M.

    1976-01-01

    Two mutants, mei1 and mei2, were isolated by screening for deficiencies occurring in the meiotic process. The sensitivity of mei1 and mei2 mutant strains to UV irradiation showed a significant increase as compared with that of the wild-type stock, hwhereas the sensitivity to γ-rays remained unchanged. The double-mutant strains were no more sensitive than each single mutant. The data indicate that both mei1 and mei2 loci are probably involved in the same pathway of excision-repair of UV-induced lesions

  5. Verification of Gamma-ray Sensitivity for BF3 Neutron Detection System

    International Nuclear Information System (INIS)

    Choi, Yu Sun; Cho, Jin Bok; Lyou, Seok Jean

    2016-01-01

    The BF3(Boron Tri-Fluorides) gas filled neutron detector(hereafter BF3 Detector) is commonly used for nuclear reactor’s startup channel due to its relatively high neutron efficiency and good discrimination against gamma-ray backgrounds. In order to measure how much this gamma-ray will affect on BF3 neutron detector performance in view of gamma noise discrimination, Multi-Channel Analyzer(MCA) is utilized for spectrum based signal analysis. The pre-test of BF3 Detector should be performed in an area where the ionization does not exceed 2.5 micro Gy/Hr(Ref.1). In this paper, the discrimination level (Voltage Unit) is verified by experimentally measurement if that discrimination level is acceptable within the criteria or not before installation. The maximum discrimination level, so called LLD, is determined by experimentally measurement. This BF3 Detector (LND20372) is insensitive under 540 micro Gy/Hr of gamma ray and 0.3V of LLD could cut off a background and gamma induced signal in a laboratory. MCA could be a convenient tool for spectrum analysis of signals that induced from gamma ray and a time saving tool rather than oscilloscope investigation due to its function to integrate all input signals at a sudden duration

  6. SENSITIVITY OF STACKED IMAGING DETECTORS TO HARD X-RAY POLARIZATION

    Energy Technology Data Exchange (ETDEWEB)

    Muleri, Fabio; Campana, Riccardo, E-mail: fabio.muleri@iaps.inaf.it [INAF-IAPS, Via del Fosso del Cavaliere 100, I-00133 Roma (Italy)

    2012-06-01

    The development of multi-layer optics which allow to focus photons up to 100 keV and more promises an enormous jump in sensitivity in the hard X-ray energy band. This technology is already planned to be exploited by future missions dedicated to spectroscopy and imaging at energies >10 keV, e.g., Astro-H and NuSTAR. Nevertheless, our understanding of the hard X-ray sky would greatly benefit from carrying out contemporaneous polarimetric measurements, because the study of hard spectral tails and of polarized emission are often two complementary diagnostics of the same non-thermal and acceleration processes. At energies above a few tens of keV, the preferred technique to detect polarization involves the determination of photon directions after a Compton scattering. Many authors have asserted that stacked detectors with imaging capabilities can be exploited for this purpose. If it is possible to discriminate those events which initially interact in the first detector by Compton scattering and are subsequently absorbed by the second layer, then the direction of scattering is singled out from the hit pixels in the two detectors. In this paper, we give the first detailed discussion of the sensitivity of such a generic design to the X-ray polarization. The efficiency and the modulation factor are calculated analytically from the geometry of the instruments and then compared with the performance as derived by means of Geant4 Monte Carlo simulations.

  7. Validation of proposed diagnostic criteria (the "Budapest Criteria") for Complex Regional Pain Syndrome.

    Science.gov (United States)

    Harden, R Norman; Bruehl, Stephen; Perez, Roberto S G M; Birklein, Frank; Marinus, Johan; Maihofner, Christian; Lubenow, Timothy; Buvanendran, Asokumar; Mackey, Sean; Graciosa, Joseph; Mogilevski, Mila; Ramsden, Christopher; Chont, Melissa; Vatine, Jean-Jacques

    2010-08-01

    Current IASP diagnostic criteria for CRPS have low specificity, potentially leading to overdiagnosis. This validation study compared current IASP diagnostic criteria for CRPS to proposed new diagnostic criteria (the "Budapest Criteria") regarding diagnostic accuracy. Structured evaluations of CRPS-related signs and symptoms were conducted in 113 CRPS-I and 47 non-CRPS neuropathic pain patients. Discriminating between diagnostic groups based on presence of signs or symptoms meeting IASP criteria showed high diagnostic sensitivity (1.00), but poor specificity (0.41), replicating prior work. In comparison, the Budapest clinical criteria retained the exceptional sensitivity of the IASP criteria (0.99), but greatly improved upon the specificity (0.68). As designed, the Budapest research criteria resulted in the highest specificity (0.79), again replicating prior work. Analyses indicated that inclusion of four distinct CRPS components in the Budapest Criteria contributed to enhanced specificity. Overall, results corroborate the validity of the Budapest Criteria and suggest they improve upon existing IASP diagnostic criteria for CRPS. Copyright (c) 2010 International Association for the Study of Pain. Published by Elsevier B.V. All rights reserved.

  8. Abnormal sensitivity of some Cockayne's syndrome cell strains to UV- and γ-rays

    International Nuclear Information System (INIS)

    Deschavanne, P.J.; Chavaudra, N.; Fertil, B.; Malaise, E.P.

    1984-01-01

    Cockayne's syndrome (CS) is a rare autosomal recessive genetic disease. Using a colony assay in vitro, we studied the sensitivity of 5 CS cell strains and two normal ones to UV- and γ-irradiation. The 5 CS strains appear to be UV-hypersensitive but the sensitivity varies widely from one strain to another. Hypersensitivity to γ-rays has been reported for 4 out of the 5 CS cell strains investigated. Repair of potentially lethal damage (PLD) after UV- and γ-irradiation was investigated by using unfed plateau cell cultures. Under these conditions, control cells show a great capacity to repair PLD. The two CS strains, which are hypersensitive to both UV- and γ-irradiation, exhibit no or only little PLD repair after treatment. The response of CS cell strains after γ-irradiation suggests a genetic heterogeneity. Three complementation groups are described in CS cells when dealing with UV radiosensitivity. However, variations in γ-ray sensitivity are reported for cells within the same UV complementation group. (Auth.)

  9. Reset charge sensitive amplifier for NaI(Tl) gamma-ray spectrometer

    International Nuclear Information System (INIS)

    Zeng, Guoqiang; Tan, Chengjun; Li, Qiang; Ge, Liangquan; Liu, Xiyao; Luo, Qun

    2015-01-01

    The time constant of the output signal of the front-end readout circuit of a traditional gamma-ray spectrometer with a NaI(Tl)+PMT structure is affected by temperature, measurement environment and the signal transmission cable, so it is difficult to get a good resolution spectrum, especially at higher counting rates. In this paper, a reset charge sensitive amplifier (RCSA) is designed for the gamma-ray spectrometer with a NaI(Tl)+PMT structure. The designed RCSA outputs a step signal, thus enabling the acquisition of double-exponential signals with a stable time constant by using the next stage of a CR differentiating circuit. The designed RCSA is mainly composed of a basic amplifying circuit, a reset circuit and a dark current compensation circuit. It provides the output step signal through the integration of the PMT output charge signal. When the amplitude of the step signal exceeds a preset voltage threshold, it triggers the reset circuit to generate a reset pulse (about 5 µs pulse width) to reset the output signal. Experimental results demonstrated that the designed RCSA achieves a charge sensitivity of 4.26×10 10 V/C, with a zero capacitance noise of 51.09 fC and a noise slope of 1.98 fC/pF. Supported by the digital shaping algorithm of the digital multi-channel analyzer (DMCA), it can maintain good energy resolution with high counting rates up to 150 kcps and with a temperature range from −19 °C to 50 °C. - Highlights: • A new reset type charge sensitive amplifier for gamma-ray spectrometer based on a photomultiplier tube is proposed. • Reset circuit formed by constant current source output a fixed width pulse to reset charge sensitive amplifier. • Photomultiplier tube dark current compensation circuit could increase the pulse through rate by decreasing reset frequency. • This amplifier outputs a step function signal that could match next stage circuit easily

  10. Sensitivity of self-powered detector probes to electron and gamma-ray fields

    International Nuclear Information System (INIS)

    Lone, M.A.; Wong, P.Y.

    1995-01-01

    A self-powered detector (SPD) is a simple, passive device that consists of a coaxial probe with a metallic outer sleeve, a mineral oxide insulating layer, and a metallic inner core. SPD's are used in nuclear reactors to monitor neutron and gamma fields. Responses of SPD's to electrons and γ-rays of various energies were investigated with Monte Carlo simulations. Transmission filters were studied for the design of threshold SPD probes used for online monitoring of the energy spectrum of high-power industrial electron accelerator beams. Filters were also investigated for the enhancement of γ-ray sensitivity of an SPD placed in a mixed electron and γ-ray field. (author). 30 refs., 1 tab., 8 figs

  11. Sensitivity of self-powered detector probes to electron and gamma-ray fields

    Energy Technology Data Exchange (ETDEWEB)

    Lone, M A; Wong, P Y [Atomic Energy of Canada Ltd., Chalk River, ON (Canada)

    1996-12-31

    A self-powered detector (SPD) is a simple, passive device that consists of a coaxial probe with a metallic outer sleeve, a mineral oxide insulating layer, and a metallic inner core. SPD`s are used in nuclear reactors to monitor neutron and gamma fields. Responses of SPD`s to electrons and {gamma}-rays of various energies were investigated with Monte Carlo simulations. Transmission filters were studied for the design of threshold SPD probes used for online monitoring of the energy spectrum of high-power industrial electron accelerator beams. Filters were also investigated for the enhancement of {gamma}-ray sensitivity of an SPD placed in a mixed electron and {gamma}-ray field. (author). 30 refs., 1 tab., 8 figs.

  12. Comparing new diagnostic criteria of 2010 ACR/EULAR with 1987 ACR criteria in rheumatoid arthritis

    Directory of Open Access Journals (Sweden)

    Fatemeh Shirani

    2017-01-01

    Full Text Available Background: Rheumatoid Arthritis (RA is a chronic inflammatory disease presenting with inflammation, tenderness and destruction of the synovial joints, resulting in severe disability and early death due to complication of disease. Previous diagnostic criteria are not useful for identifying patients who need early treatment. Thus, new diagnostic criteria for faster diagnosis of disease are introduced in 2010. The aim of this study was to compared 1987 ACR (American College of Rheumatology criteria and 2010 ACR/EULAR (European League Against Rheumatism classification criteria for diagnosis of rheumatoid arthritis. Methods: In this Cohort prospective study, patients with early arthritis were evaluated   according to the old and new diagnostic criteria and followed-up every two monthly for one year (2012-2013 in Hazrat-e Rasool University Hospital, Tehran. Inclusion criteria of this study were age more than 18 year and indefinite diagnosis of arthritis. For all of patients physical examination by expert rheumatologist was done and lab data include erythrocyte sedimentation rate (ESR, C-reactive protein (CRP, anti-cyclic citrullinated peptide (Anti-CCP and rheumatoid factor was requested. The sensitivity, specificity, positive and negative predictive values were then determined for each diagnostic criteria. Results: In this study 104 patients including 28 males (26.9% and 76 females (73.1% with the mean age of 44.2±13.7 years were included. At the end of one year follow-up, 82 were diagnosed to have RA while other 22 patients were not categorized as RA. Sensitivity for ESR, CRP, Anti-CCP and rheumatoid factor in 2010 ACR/EULAR criteria was 52%, 19%, 48%, 28% and specificity for them was 45%, 71%, 27%, 79% respectively. Number of small and large joint arthritis were more in patients with Rheumatoid Arthritis (RA rather than other arthritis (P=0.0001. Sensitivity and specificity for small joints involvement was 87% and 54% and for large joints

  13. Light-sensitive elements for radiographic use and process for the formation of an X-ray image

    International Nuclear Information System (INIS)

    Bussi, G.; Cavallo, E.

    1990-01-01

    A light-sensitive silver halide element for radiographic use with X-ray intensifying screens comprising coated on at least one side of a transparent support base at least a spectrally sensitized silver halide emulsion layer and, between the base and a silver halide emulsion layer, a hydrophillic colloid layer containing a) substantially light-insensitivelow iodide silver bromoiodide grains having an avergae grain size in therange of from 0.01 to 0.1 μm on which a spectral sensitizing dye is adsorbed to form a J-band, said dye adsorbed on said grains having a significant portion of its absorption in a region of the electromagnetic spectrum corresponding substantially to the spectral sensitivity of the silver halide emulsion, and b) dispersed zinc oxide particles. The invention allows the use of low coverage weights of silver halide light-sensitive elements and provides X-ray images with a favorable image quality and sensitivity ratio. (author)

  14. Light-sensitive elements for radiographic use and process for the formation of an X-ray image

    Energy Technology Data Exchange (ETDEWEB)

    Bussi, G; Cavallo, E

    1990-12-15

    A light-sensitive silver halide element for radiographic use with X-ray intensifying screens comprising coated on at least one side of a transparent support base at least a spectrally sensitized silver halide emulsion layer and, between the base and a silver halide emulsion layer, a hydrophillic colloid layer containing (a) substantially light-insensitivelow iodide silver bromoiodide grains having an avergae grain size in therange of from 0.01 to 0.1 {mu}m on which a spectral sensitizing dye is adsorbed to form a J-band, said dye adsorbed on said grains having a significant portion of its absorption in a region of the electromagnetic spectrum corresponding substantially to the spectral sensitivity of the silver halide emulsion, and (b) dispersed zinc oxide particles. The invention allows the use of low coverage weights of silver halide light-sensitive elements and provides X-ray images with a favorable image quality and sensitivity ratio. (author).

  15. Sensitivity of current criteria for the diagnosis of behavioral variant frontotemporal dementia

    Science.gov (United States)

    Piguet, O; Hornberger, M; Shelley, B P.; Kipps, C M.; Hodges, J R.

    2009-01-01

    Background: Diagnosis of behavioral variant frontotemporal dementia (bvFTD) relies on criteria that are constraining and potentially ambiguous. Some features are open to clinical interpretation and their prevalence unknown. This study investigated the sensitivity of current diagnostic criteria in a large group of patients with bvFTD. Methods: Forty-five patients with clear evidence of bvFTD as judged by progressive clinical decline (>3 years) with marked frontal features and significant frontal brain atrophy on brain MRI were included. Thirty-two have died; pathologic confirmation of frontotemporal lobar degeneration was found in all 18 coming to autopsy. We established the prevalence of core and supportive diagnostic features at presentation and with disease progression. Results: Only 25/45 patients (56%) showed all five core features necessary for a diagnosis of bvFTD at initial presentation and 33/45 (73%) as their disease progressed. Two core features, emotional blunting and loss of insight, were never observed in 25% and 13% of cases. Executive dysfunction, hyperorality, mental inflexibility, and distractibility were the only supportive features present in >50% of cases at initial presentation. Although not a diagnostic feature, impaired activities of daily living was present in 33/45 patients (73%). Conclusions: Strict application of the criteria misses a significant proportion of patients. Many supportive features have low prevalence and are clinically not useful. Revision of the criteria to include level of certainty (definite, probable, possible) dependent on the number of features present and the presence of ancillary information (e.g., brain atrophy, neuropsychological abnormalities, impaired activities of daily living) is encouraged. GLOSSARY ACE = Addenbrooke’s Cognitive Examination; ADL = activities of daily living; bvFTD = behavioral variant frontotemporal dementia; MMSE = Mini-Mental State Examination. PMID:19237702

  16. Development of aquatic life criteria for triclosan and comparison of the sensitivity between native and non-native species.

    Science.gov (United States)

    Wang, Xiao-Nan; Liu, Zheng-Tao; Yan, Zhen-Guang; Zhang, Cong; Wang, Wei-Li; Zhou, Jun-Li; Pei, Shu-Wei

    2013-09-15

    Triclosan (TCS) is an antimicrobial agent which is used as a broad-spectrum bacteriostatic and found in personal care products, and due to this it is widely spread in the aquatic environment. However, there is no paper dealing with the aquatic life criteria of TCS, mainly result from the shortage of toxicity data of different taxonomic levels. In the present study, toxicity data were obtained from 9 acute toxicity tests and 3 chronic toxicity tests using 9 Chinese native aquatic species from different taxonomic levels, and the aquatic life criteria was derived using 3 methods. Furthermore, differences of species sensitivity distributions (SSD) between native and non-native species were compared. Among the tested species, demersal fish Misgurnus anguillicaudatus was the most sensitive species, and the fishes were more sensitive than the aquatic invertebrates of Annelid and insect, and the insect was the least sensitive species. The comparison showed that there was no significant difference between SSDs constructed from native and non-native taxa. Finally, a criterion maximum concentration of 0.009 mg/L and a criterion continuous concentration of 0.002 mg/L were developed based on different taxa, according to the U.S. Environmental Protection Agency guidelines. Copyright © 2013 Elsevier B.V. All rights reserved.

  17. Sensitivity of photon-counting based K-edge imaging in X-ray computed tomography.

    Science.gov (United States)

    Roessl, Ewald; Brendel, Bernhard; Engel, Klaus-Jürgen; Schlomka, Jens-Peter; Thran, Axel; Proksa, Roland

    2011-09-01

    The feasibility of K-edge imaging using energy-resolved, photon-counting transmission measurements in X-ray computed tomography (CT) has been demonstrated by simulations and experiments. The method is based on probing the discontinuities of the attenuation coefficient of heavy elements above and below the K-edge energy by using energy-sensitive, photon counting X-ray detectors. In this paper, we investigate the dependence of the sensitivity of K-edge imaging on the atomic number Z of the contrast material, on the object diameter D , on the spectral response of the X-ray detector and on the X-ray tube voltage. We assume a photon-counting detector equipped with six adjustable energy thresholds. Physical effects leading to a degradation of the energy resolution of the detector are taken into account using the concept of a spectral response function R(E,U) for which we assume four different models. As a validation of our analytical considerations and in order to investigate the influence of elliptically shaped phantoms, we provide CT simulations of an anthropomorphic Forbild-Abdomen phantom containing a gold-contrast agent. The dependence on the values of the energy thresholds is taken into account by optimizing the achievable signal-to-noise ratios (SNR) with respect to the threshold values. We find that for a given X-ray spectrum and object size the SNR in the heavy element's basis material image peaks for a certain atomic number Z. The dependence of the SNR in the high- Z basis-material image on the object diameter is the natural, exponential decrease with particularly deteriorating effects in the case where the attenuation from the object itself causes a total signal loss below the K-edge. The influence of the energy-response of the detector is very important. We observed that the optimal SNR values obtained with an ideal detector and with a CdTe pixel detector whose response, showing significant tailing, has been determined at a synchrotron differ by factors of

  18. Development of Position-Sensitive Magnetic Calorimeters for X-Ray Astronomy

    Science.gov (United States)

    Bandler, SImon; Stevenson, Thomas; Hsieh, Wen-Ting

    2011-01-01

    Metallic magnetic calorimeters (MMC) are one of the most promising devices to provide very high energy resolution needed for future astronomical x-ray spectroscopy. MMC detectors can be built to large detector arrays having thousands of pixels. Position-sensitive magnetic (PoSM) microcalorimeters consist of multiple absorbers thermally coupled to one magnetic micro calorimeter. Each absorber element has a different thermal coupling to the MMC, resulting in a distribution of different pulse shapes and enabling position discrimination between the absorber elements. PoSMs therefore achieve the large focal plane area with fewer number of readout channels without compromising spatial sampling. Excellent performance of PoSMs was achieved by optimizing the designs of key parameters such as the thermal conductance among the absorbers, magnetic sensor, and heat sink, as well as the absorber heat capacities. Micro fab ri - cation techniques were developed to construct four-absorber PoSMs, in which each absorber consists of a two-layer composite of bismuth and gold. The energy resolution (FWHM full width at half maximum) was measured to be better than 5 eV at 6 keV x-rays for all four absorbers. Position determination was demonstrated with pulse-shape discrimination, as well as with pulse rise time. X-ray microcalorimeters are usually designed to thermalize as quickly as possible to avoid degradation in energy resolution from position dependence to the pulse shapes. Each pixel consists of an absorber and a temperature sensor, both decoupled from the cold bath through a weak thermal link. Each pixel requires a separate readout channel; for instance, with a SQUID (superconducting quantum interference device). For future astronomy missions where thousands to millions of resolution elements are required, having an individual SQUID readout channel for each pixel becomes difficult. One route to attaining these goals is a position-sensitive detector in which a large continuous or

  19. Pelvic X-ray examinations in follow-up of hip arthroplasty or femoral osteosynthesis – Dose reduction and quality criteria

    Energy Technology Data Exchange (ETDEWEB)

    Kloth, Jost Karsten, E-mail: jost.kloth@med.uni-heidelberg.de [Diagnostic and Interventional Radiology, University Hospital Heidelberg, Im Neuenheimer Feld 110, D-69120 Heidelberg (Germany); Rickert, Markus, E-mail: markus.rickert@ortho.med.uni-giessen.de [Department of Orthopaedics and Orthopaedic Surgery, University Hospital Giessen and Marburg, Klinikstrasse 33, D-35392 Giessen (Germany); Gotterbarm, Tobias, E-mail: tobias.gotterbarm@med.uni-heidelberg.de [Orthopedic and Trauma Surgery, University Hospital Heidelberg, Schlierbacher Landstraße 200a, D-69118 Heidelberg (Germany); Stiller, Wolfram, E-mail: wolfram.stiller@med.uni-heidelberg.de [Diagnostic and Interventional Radiology, University Hospital Heidelberg, Im Neuenheimer Feld 110, D-69120 Heidelberg (Germany); Burkholder, Iris, E-mail: stabil@burkholder.de [Department of Nursing and Health, University of Applied Sciences of the Saarland, Goebenstrasse 40, D-66117 Saarbruecken (Germany); Kauczor, Hans-Ulrich, E-mail: hans-ulrich.kauczor@med.uni-heidelberg.de [Diagnostic and Interventional Radiology, University Hospital Heidelberg, Im Neuenheimer Feld 110, D-69120 Heidelberg (Germany); Ewerbeck, Volker, E-mail: volker.ewerbeck@med.uni-heidelberg.de [Orthopedic and Trauma Surgery, University Hospital Heidelberg, Schlierbacher Landstraße 200a, D-69118 Heidelberg (Germany); Weber, Marc-André, E-mail: marcandre.weber@med.uni-heidelberg.de [Diagnostic and Interventional Radiology, University Hospital Heidelberg, Im Neuenheimer Feld 110, D-69120 Heidelberg (Germany)

    2015-05-15

    Highlights: • Pelvic radiographs with speed class 400 and 800 in follow-up of hip arthroplasty were compared. • Radiographs with reduced dose (800) were not inferior to those with standard dose (400). • We recommend speed class 800 as new reference parameter in these examinations. - Abstract: Objective: Digital plain radiographs of the pelvis are frequently performed in follow-up examinations of patients who received total hip arthroplasty (THA) or osteosynthesis (OS). Thus, the purpose was to reduce the radiation dose and to determine objective quality control criteria to ensure accurate assessment. Materials and methods: Institutional review board approval was obtained. In this prospective randomized study, 289 patients underwent X-ray examination of the pelvis as follow up after receiving THA or OS with standard and reduced dose. The evaluation of the plain radiographs was conducted using the following criteria: bone–implant interface, implant–implant discrimination, implant–surface character and periarticular heterotopic ossification. Two radiologists evaluated these criteria using a score ranging from 1 (definitely assessable) to 4 (not assessable). If a single criterion had been evaluated with a score of 3 or more or more than 2 criteria with 2 points, the radiograph was scored as “not assessable“. The study was designed as non-inferiority-trial. Results: Seven (2.4%) examined X-rays were scored as not assessable. There was no statistical inferiority between the examinations with standard (0.365 mSv) or reduced dose (0.211 mSv). Reduced dose only led to limitations in the evaluation of ceramic components with low clinical impact in most scenarios. Conclusion: Plain radiography of the pelvis in patients with THA or OS can be performed with a dose reduction of about 42% without a loss of important information. The obtained quality control criteria were clinically applicable.

  20. (U) Second-Order Sensitivity Analysis of Uncollided Particle Contributions to Radiation Detector Responses Using Ray-Tracing

    Energy Technology Data Exchange (ETDEWEB)

    Favorite, Jeffrey A. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-11-30

    The Second-Level Adjoint Sensitivity System (2nd-LASS) that yields the second-order sensitivities of a response of uncollided particles with respect to isotope densities, cross sections, and source emission rates is derived in Refs. 1 and 2. In Ref. 2, we solved problems for the uncollided leakage from a homogeneous sphere and a multiregion cylinder using the PARTISN multigroup discrete-ordinates code. In this memo, we derive solutions of the 2nd-LASS for the particular case when the response is a flux or partial current density computed at a single point on the boundary, and the inner products are computed using ray-tracing. Both the PARTISN approach and the ray-tracing approach are implemented in a computer code, SENSPG. The next section of this report presents the equations of the 1st- and 2nd-LASS for uncollided particles and the first- and second-order sensitivities that use the solutions of the 1st- and 2nd-LASS. Section III presents solutions of the 1st- and 2nd-LASS equations for the case of ray-tracing from a detector point. Section IV presents specific solutions of the 2nd-LASS and derives the ray-trace form of the inner products needed for second-order sensitivities. Numerical results for the total leakage from a homogeneous sphere are presented in Sec. V and for the leakage from one side of a two-region slab in Sec. VI. Section VII is a summary and conclusions.

  1. Position sensitive detector for X-ray photons

    International Nuclear Information System (INIS)

    Barbosa, A.F.

    1988-01-01

    This work reports the theoretical basis and the details of the construction process, characterization and application of gas X-ray position sensitive detectors. The unidimensional detector consists of a gas camera (argon and CH 4 ), a metallic anode, a cathode and a delay line. Details of the construction process are given in order to allow the reproduction of the detector. It has been characterized by measuring its spatial resolution, homogeneity and linerity. The built linear detector has been used to obtain diffraction diagrams from polycrystalline silicon, C 23 H 48 paraffin and glassy carbon. These diagrams have been compared with those obtained under equivalent conditions with a conventional proportional detector by the step scanning method. It has been shown that the detector provides diffraction diagrams of equivalent quality to those obtained by the step scanning method, in appreciably lower time intervals. (author) [pt

  2. The Einstein Observatory Extended Medium-Sensitivity Survey. I - X-ray data and analysis

    Science.gov (United States)

    Gioia, I. M.; Maccacaro, T.; Schild, R. E.; Wolter, A.; Stocke, J. T.

    1990-01-01

    This paper presents the results of the analysis of the X-ray data and the optical identification for the Einstein Observatory Extended Medium-Sensitivity Survey (EMSS). The survey consists of 835 serendipitous sources detected at or above 4 times the rms level in 1435 imaging proportional counter fields with centers located away from the Galactic plane. Their limiting sensitivities are about (5-300) x 10 to the -14th ergs/sq cm sec in the 0.3-3.5-keV energy band. A total area of 778 square deg of the high-Galactic-latitude sky has been covered. The data have been analyzed using the REV1 processing system, which takes into account the nonuniformities of the detector. The resulting EMSS catalog of X-ray sources is a flux-limited and homogeneous sample of astronomical objects that can be used for statistical studies.

  3. Stage sensitivity and dose response of meiotic chromosomes of pollen mother cells of Tradescantia to X-rays

    Energy Technology Data Exchange (ETDEWEB)

    Ma, T H; Kontos, Jr, G J; Anderson, V A [Western Illinois Univ., Macomb (USA). Dept. of Biological Sciences

    1980-05-01

    Chromosome damage induced by physical and chemical mutagens can be quantitated by the frequencies of micronuclei (MCN) produced in tetrads of the meiotic pollen mother cells of Tradescantia, i.e. the 'MCN-in-Tetrad' test. The stage sensitivity and dose response of these meiocytes to low exposures of X-rays was studied to improve the efficiency and reliability of this test. Stage sensitivity was determined by observing, at 3 hr intervals, the frequencies of X-ray (35 rads)-induced MCN in tetrads from a series of 16 fixations of tetrad-containing inflorescences. Late stages of meiosis (3-9 hr post-irradiation fixation groups) were insensitive (5-14 MCN/100 tetrads). Relatively high sensitivity was exhibited in the early stages of meiosis. The first and second sensitive peaks (62 and 61 MCN/100 tetrads) centered around the 21 and 39 hr post-irradiation fixation groups respectively. Control groups yielded around 3-4 MCN/100 tetrads. A dose-response relation for MCN was determined by treating early stages of meiotic pollen mother cells with X-ray exposures ranging from 9.5 to 57.5 rads. A linear regression line was established with about 20 MCN/100 tetrads per 10 rad increment.

  4. Low sensitivity of qSOFA, SIRS criteria and sepsis definition to identify infected patients at risk of complication in the prehospital setting and at the emergency department triage.

    Science.gov (United States)

    Tusgul, Selin; Carron, Pierre-Nicolas; Yersin, Bertrand; Calandra, Thierry; Dami, Fabrice

    2017-11-03

    Sepsis is defined as life-threatening organ dysfunction caused by a host response to infection. The quick SOFA (qSOFA) score has been recently proposed as a new bedside clinical score to identify patients with suspected infection at risk of complication (intensive care unit (ICU) admission, in-hospital mortality). The aim of this study was to measure the sensitivity of the qSOFA score, SIRS criteria and sepsis definitions to identify the most serious sepsis cases in the prehospital setting and at the emergency department (ED) triage. We performed a retrospective study of all patients transported by emergency medical services (EMS) to the Lausanne University Hospital (CHUV) over twelve months. All patients with a suspected or proven infection after the ED workup were included. We retrospectively analysed the sensitivity of the qSOFA score (≥2 criteria), SIRS criteria (≥2 clinical criteria) and sepsis definition (SIRS criteria + one sign of organ dysfunction or hypoperfusion) in the pre-hospital setting and at the ED triage as predictors of ICU admission, ICU stay of ≥3 days and early (i.e. 48 h) mortality. No direct comparison between the three tools was attempted. Among 11,411 patients transported to the University hospital, 886 (7.8%) were included. In the pre-hospital setting, the sensitivity of qSOFA reached 36.3% for ICU admission, 17.4% for ICU stay of three days or more and 68.0% for 48 h mortality. The sensitivity of SIRS criteria reached 68.8% for ICU admission, 74.6% for ICU stay of three days or more and 64.0% for 48 h mortality. The sensitivity of sepsis definition did not reach 60% for any outcome. At ED triage, the sensitivity of qSOFA reached 31.2% for ICU admission, 30.5% for ICU stay of ≥3 days and 60.0% for mortality at 48 h. The sensitivity of SIRS criteria reached 58.8% for ICU admission, 57.6% for ICU stay of ≥3 days 80.0% for mortality at 48 h. The sensitivity of sepsis definition reached 60.0% for 48 h mortality. Incidence

  5. Evidence for three types of x-ray damage repair in yeast and sensitivity of totally repair deficient strains to sunlight

    International Nuclear Information System (INIS)

    Game, J.C.; Schild, D.; Mortimer, R.K.

    1987-01-01

    Mutants of yeast that confer sensitivity to x-rays are known to fall into two epistasis groups, called here the RAD51 and RAD18 groups, which are each thought to control a different type of x-ray repair. They examine here the role of genes in a third repair pathways in x-ray repair. RAD1 and RAD3 are known to be important in the repair of pyrimidine dimers after uv-irradiation. They find that these genes can also play an important role in x-ray repair, but that this role is only exposed when both the other pathways of x-ray repair are blocked. Double mutants blocked in the RAD51 and RAD18 pathways are significantly less x-ray sensitive than triple mutants blocked in these pathways but also mutant in either the RAD1 or RAD3 genes. In a related experiment, they tested the importance of DNA repair in nature by determining the sensitivity to natural unfiltered sunlight of a strain lacking all known DNA repair pathways. They constructed a quadruple mutant strain containing RAD1-1, RAD18-2, RAD51-1 and PHR1-1. The latter mutation blocks the cell's ability to photoreactivate uv damage. They found that this strain was so sensitive to sunlight that less than three seconds' exposure would cause an average of one lethal hit per cell, and survival was less than 2% after ten seconds' exposure. Wild type yeast at sea level showed no killing after thirty minutes. the quadruple mutant is approximately one thousand times more sensitive to sunlight than the related wild type

  6. Stage sensitivity and dose response of meiotic chromosomes of pollen mother cells of Tradescantia to X-rays

    International Nuclear Information System (INIS)

    Ma, T.-H.; Kontos, G.J. Jr.; Anderson, V.A.

    1980-01-01

    Chromosome damage induced by physical and chemical mutagens can be quantitated by the frequencies of micronuclei (MCN) produced in tetrads of the meiotic pollen mother cells of Tradescantia, i.e. the 'MCN-in-Tetrad' test. The stage sensitivity and dose response of these meiocytes to low exposures of X-rays was studied to improve the efficiency and reliability of this test. Stage sensitivity was determined by observing, at 3 hr intervals, the frequencies of X-ray (35 rads)-induced MCN in tetrads from a series of 16 fixations of tetrad-containing inflorescences. Late stages of meiosis (3-9 hr post-irradiation fixation groups) were insensitive (5-14 MCN/100 tetrads). Relatively high sensitivity was exhibited in the early stages of meiosis. The first and second sensitive peaks (62 and 61 MCN/100 tetrads) centered around the 21 and 39 hr post-irradiation fixation groups respectively. Control groups yielded around 3-4 MCN/100 tetrads. A dose-response relation for MCN was determined by treating early stages of meiotic pollen mother cells with X-ray exposures ranging from 9.5 to 57.5 rads. A linear regression line was established with about 20 MCN/100 tetrads per 10 rad increment. (author)

  7. Direction-Sensitive Hand-Held Gamma-Ray Spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Mukhopadhyay, S.

    2012-10-04

    A novel, light-weight, hand-held gamma-ray detector with directional sensitivity is being designed. The detector uses a set of multiple rings around two cylindrical surfaces, which provides precise location of two interaction points on two concentric cylindrical planes, wherefrom the source location can be traced back by back projection and/or Compton imaging technique. The detectors are 2.0 × 2.0 mm europium-doped strontium iodide (SrI2:Eu2+) crystals, whose light output has been measured to exceed 120,000 photons/MeV, making it one of the brightest scintillators in existence. The crystal’s energy resolution, less than 3% at 662 keV, is also excellent, and the response is highly linear over a wide range of gamma-ray energies. The emission of SrI2:Eu2+ is well matched to both photo-multiplier tubes and blue-enhanced silicon photodiodes. The solid-state photomultipliers used in this design (each 2.0 × 2.0 mm) are arrays of active pixel sensors (avalanche photodiodes driven beyond their breakdown voltage in reverse bias); each pixel acts as a binary photon detector, and their summed output is an analog representation of the total photon energy, while the individual pixel accurately defines the point of interaction. A simple back-projection algorithm involving cone-surface mapping is being modeled. The back projection for an event cone is a conical surface defining the possible location of the source. The cone axis is the straight line passing through the first and second interaction points.

  8. X-ray-induced chromosome aberrations in Down lymphocytes: an explanation of their increased sensitivity

    International Nuclear Information System (INIS)

    Preston, R.J.

    1981-01-01

    Unstimulated lymphocytes from individuals with Down Syndrome (trisomy 21) are more sensitive to the induction of dicentric and ring aberrations by X rays than normal lymphocytes. Several explanations involving the more rapid rejoining of X-ray--induced lesions in Down cells have been offered. It is shown here that the repair of the DNA damage converted into chromosome aberrations is more rapid in Down cells than normal cells. This more rapid repair results in a higher probability of producing chromosomes aberrations, and hence higher aberration frequencies in Down than normal cells

  9. X-ray-induced chromosome aberrations in Down lymphocytes: an explanation of their increased sensitivity

    International Nuclear Information System (INIS)

    Preston, R.J.

    1981-01-01

    Unstimulated lymphocytes from individuals with Down Syndrome (trisomy 21) are more sensitive to the induction of dicentric and ring aberrations by X rays than normal lymphocytes. Several explanations involving the more rapid rejoining of X-ray-induced lesions in Down cells have been offered. It is shown here that the repair of the DNA damage converted into chromosome aberrations is more rapid in Down cells than normal cells. This more rapid repair results in a higher probability of producing chromosome aberrations, and hence higher aberration frequencies in Down than normal cells

  10. Investigation of the pulse shape analysis for the position sensitive γ-ray spectrometer AGATA

    Energy Technology Data Exchange (ETDEWEB)

    Lewandowski, Lars; Birkenbach, Benedikt; Reiter, Peter [Institut fuer Kernphysik Koeln (Germany); Collaboration: AGATA-Collaboration

    2015-07-01

    The next generation of γ-ray spectrometers like AGATA will provide high quality γ-ray spectra by the new Gamma-Ray Tracking technique (GRT). Position sensitive HPGe detectors will allow for precise Doppler correction and small broadening of lines for spectroscopy at relativistic energies. GRT is based on the interaction position of the γ-rays within the volume of the highly segmented germanium detectors provided by Pulse Shape Analysis (PSA) methods. The proof of principle of GRT was already demonstrated with great success however systematic deviations from expected results occur. The parameterization of the following detector properties and their impact on PSA were thoroughly investigated and optimized: electron and hole mobility, crystal axis orientation, space charge distributions, crystal impurities, response functions of preamplifiers and digitizers, linear and differential crosstalk, time alignment of pulses and the distance metric. Results of an improved PSA performance are presented.

  11. Simultaneous acquisition of X-ray spectra using a multi-wire, position-sensitive gas flow detector

    International Nuclear Information System (INIS)

    Beaven, Peter A.; Marmotti, Mauro; Kampmann, Reinhard; Knoth, Joachim; Schwenke, Heinrich

    2003-01-01

    A multi-wire, gas-filled position-sensitive detector has been developed for the simultaneous recording of wavelength-dispersed X-ray signals that enables X-ray fluorescence spectrometry with a limited multi-element capability in the low Z element range. Details of the modular construction of the detector are given. The detector performance was characterized using Al-Kα radiation and a variable slit system. The detector has been applied in a laboratory spectrometer equipped with an electron source and a double multilayer mirror device as the wavelength-dispersing element. Spectra from Al and Si obtained in the simultaneous acquisition mode show good agreement with calculations performed using a ray-tracing model

  12. X-ray sensitization of chromatids with unifilarly and bifilarly substituted DNA

    International Nuclear Information System (INIS)

    Wolff, S.

    1981-01-01

    When cells are grown for two rounds of DNA replication in the presence of the thymidine analogue 5-bromodeoxyuridine, chromosomes containing one chromatid with unifilarly substituted DNA and one with bifilarly substituted DNA are found. These can be distinguished by harlequin staining techniques that stain one chromatid dark and one light. When the degree of substitution is 60% or greater, 3 times as many X-ray-induced chromatid breaks are produced as in unsubstituted chromatids. This represents maximal sensitization. The unifilarly substituted (dark) chromatid is as sensitive as its bifilarly substituted (light) sister chromatid. If cells are grown in low concentrations of 5-bromodeoxyuridine (BrdUrd), then the amount of substitution is less and the bifilarly substituted chromatic is more sensitive than the unifilarly substituted one. When large numbers of cells are grown in very low concentrations of BrdUrd, the analogue is almost completely depleted during the first round of replication leading to harlequin chromosomes containing one unsubstituted (dark) and one unifilarly substituted (light) chromatid. Under these conditions a maximal sensitization between light-staining and dark-staining chromatids can occur. This can be confused with the differential sensitivity between unifilarly and bifilarly substituted chromatids. The apparent discrepant results obtained by different investigators are most likely caused by the use of very low levels of BrdUrd in some of the experiments. (orig.)

  13. Cosolvent-free polymer gel dosimeters with improved dose sensitivity and resolution for x-ray CT dose response

    Energy Technology Data Exchange (ETDEWEB)

    Chain, J N M; McAuley, K B [Department of Chemical Engineering, Queen' s University, Kingston, K7L 3N6 (Canada); Jirasek, A [Department of Physics and Astronomy, University of Victoria, Victoria, V8W 3P6 (Canada); Schreiner, L J, E-mail: kim.mcauley@chee.queensu.ca [Cancer Centre of Southeastern Ontario, Kingston, K7L 5P9 (Canada)

    2011-04-07

    This study reports new N-isopropylacrylamide (NIPAM) polymer gel recipes with increased dose sensitivity and improved dose resolution for x-ray CT readout. NIPAM can be used to increase the solubility of N, N'-methylenebisacrylamide (Bis) in aqueous solutions from approximately 3% to 5.5% by weight, enabling the manufacture of dosimeters containing up to 19.5%T, which is the total concentration of NIPAM and Bis by weight. Gelatin is shown to have a mild influence on dose sensitivity when gels are imaged using x-ray CT, and a stronger influence when gels are imaged optically. Phantoms that contain only 3% gelatin and 5 mM tetrakis hydroxymethyl phosphonium chloride are sufficiently stiff for dosimetry applications. The best cosolvent-free gel formulation has a dose sensitivity in the linear range ({approx}0.88 H Gy{sup -1}) that is a small improvement compared to the best NIPAM-based gels that incorporate isopropanol as a cosolvent ({approx}0.80 H Gy{sup -1}). This new gel formulation results in enhanced dose resolution ({approx}0.052 Gy) for x-ray CT readout, making clinical applications of this imaging modality more feasible.

  14. Cosolvent-free polymer gel dosimeters with improved dose sensitivity and resolution for x-ray CT dose response

    International Nuclear Information System (INIS)

    Chain, J N M; McAuley, K B; Jirasek, A; Schreiner, L J

    2011-01-01

    This study reports new N-isopropylacrylamide (NIPAM) polymer gel recipes with increased dose sensitivity and improved dose resolution for x-ray CT readout. NIPAM can be used to increase the solubility of N, N'-methylenebisacrylamide (Bis) in aqueous solutions from approximately 3% to 5.5% by weight, enabling the manufacture of dosimeters containing up to 19.5%T, which is the total concentration of NIPAM and Bis by weight. Gelatin is shown to have a mild influence on dose sensitivity when gels are imaged using x-ray CT, and a stronger influence when gels are imaged optically. Phantoms that contain only 3% gelatin and 5 mM tetrakis hydroxymethyl phosphonium chloride are sufficiently stiff for dosimetry applications. The best cosolvent-free gel formulation has a dose sensitivity in the linear range (∼0.88 H Gy -1 ) that is a small improvement compared to the best NIPAM-based gels that incorporate isopropanol as a cosolvent (∼0.80 H Gy -1 ). This new gel formulation results in enhanced dose resolution (∼0.052 Gy) for x-ray CT readout, making clinical applications of this imaging modality more feasible.

  15. 2013 American College of Rheumatology/European League against rheumatism classification criteria for systemic sclerosis outperform the 1980 criteria: data from the Canadian Scleroderma Research Group.

    Science.gov (United States)

    Alhajeri, Hebah; Hudson, Marie; Fritzler, Marvin; Pope, Janet; Tatibouet, Solène; Markland, Janet; Robinson, David; Jones, Niall; Khalidi, Nader; Docherty, Peter; Kaminska, Elzbieta; Masetto, Ariel; Sutton, Evelyn; Mathieu, Jean-Pierre; Ligier, Sophie; Grodzicky, Tamara; LeClercq, Sharon; Thorne, Carter; Gyger, Geneviève; Smith, Douglas; Fortin, Paul R; Larché, Maggie; Baron, Murray

    2015-04-01

    The goal of this study was to determine the sensitivity of the new 2013 classification criteria for systemic sclerosis (SSc; scleroderma) in an independent cohort of SSc subjects and to assess the contribution of individual items of the criteria to the overall sensitivity. SSc subjects from the Canadian Scleroderma Research Group cohort were assessed. Sensitivity was determined in several subgroups of patients. In patients without the criterion of skin thickening proximal to the metacarpophalangeal (MCP) joints, we recalculated sensitivity after removing the individual criterion. A total of 724 SSc patients were included. Most were women (86%), mean age was 55.8 years, mean disease duration was 10.9 years, and 59% had limited cutaneous SSc (lcSSc). Overall, the sensitivity of the 2013 criteria was 98.3% compared to 88.3% for the 1980 criteria. This pattern was consistent among those with lcSSc (98.8% versus 85.6%), anticentromere antibodies (98.9% versus 79.8%), disease duration ≤3 years (98.7% versus 84.7%), and no skin involvement proximal to the MCP joints (97% versus 60%). In the latter subgroup, removing Raynaud's phenomenon and sclerodactyly from the criteria reduced the sensitivity to 77% and 79%, respectively. Removing both sclerodactyly and puffy fingers reduced the sensitivity to 62%. The 2013 SSc classification criteria classify more SSc patients than the 1980 criteria. The improvement in sensitivity is most striking in those with lcSSc, especially those without skin involvement proximal to the MCP joints. The addition of Raynaud's phenomenon and puffy fingers to the 2013 criteria accounts for important gains in sensitivity. Copyright © 2015 by the American College of Rheumatology.

  16. Order of magnitude sensitivity increase in X-ray Fluorescence Computed Tomography (XFCT) imaging with an optimized spectro-spatial detector configuration: theory and simulation.

    Science.gov (United States)

    Ahmad, Moiz; Bazalova, Magdalena; Xiang, Liangzhong; Xing, Lei

    2014-05-01

    The purpose of this study was to increase the sensitivity of XFCT imaging by optimizing the data acquisition geometry for reduced scatter X-rays. The placement of detectors and detector energy window were chosen to minimize scatter X-rays. We performed both theoretical calculations and Monte Carlo simulations of this optimized detector configuration on a mouse-sized phantom containing various gold concentrations. The sensitivity limits were determined for three different X-ray spectra: a monoenergetic source, a Gaussian source, and a conventional X-ray tube source. Scatter X-rays were minimized using a backscatter detector orientation (scatter direction > 110(°) to the primary X-ray beam). The optimized configuration simultaneously reduced the number of detectors and improved the image signal-to-noise ratio. The sensitivity of the optimized configuration was 10 μg/mL (10 pM) at 2 mGy dose with the mono-energetic source, which is an order of magnitude improvement over the unoptimized configuration (102 pM without the optimization). Similar improvements were seen with the Gaussian spectrum source and conventional X-ray tube source. The optimization improvements were predicted in the theoretical model and also demonstrated in simulations. The sensitivity of XFCT imaging can be enhanced by an order of magnitude with the data acquisition optimization, greatly enhancing the potential of this modality for future use in clinical molecular imaging.

  17. Comparison of sensitivities and detection limits between direct excitation and secondary excitation modes in energy dispersive x-ray fluorescence analysis

    International Nuclear Information System (INIS)

    Artz, B.E.; Short, M.A.

    1976-01-01

    A comparison was made between the direct tube excitation mode and the secondary target excitation mode using a Kevex 0810 energy dispersive x-ray fluorescence system. Relative sensitivities and detection limits were determined with two system configurations. The first configuration used a standard, high power, x-ray fluorescence tube to directly excite the specimen. Several x-ray tubes, including chromium, molybdenum, and tungsten, both filtered and not filtered, were employed. The second configuration consisted of using the x-ray tube to excite a secondary target which in turn excited the specimen. Appropriate targets were compared to the direct excitation results. Relative sensitivities and detection limits were determined for K-series lines for elements from magnesium to barium contained in a low atomic number matrix and in a high atomic number matrix

  18. Arrhythmogenic Right Ventricular Dysplasia/Cardiomyopathy Diagnostic Task Force Criteria Impact of New Task Force Criteria

    NARCIS (Netherlands)

    Cox, Moniek G. P. J.; van der Smagt, Jasper J.; Noorman, Maartje; Wiesfeld, Ans C.; Volders, Paul G. A.; van Langen, Irene M.; Atsma, Douwe E.; Dooijes, Dennis; Houweling, Arjan C.; Loh, Peter; Jordaens, Luc; Arens, Yvonne; Cramer, Maarten J.; Doevendans, Pieter A.; van Tintelen, Peter; Wilde, Arthur A. M.; Hauer, Richard N. W.

    Background-Arrhythmogenic Right Ventricular Dysplasia/Cardiomyopathy (ARVD/C) Diagnostic Task Force Criteria (TFC) proposed in 1994 are highly specific but lack sensitivity. A new international task force modified criteria to improve diagnostic yield. A comparison of diagnosis by 1994 TFC versus

  19. Lower Ionosphere Sensitivity to Solar X-ray Flares Over a Complete Solar Cycle Evaluated From VLF Signal Measurements

    Science.gov (United States)

    Macotela, Edith L.; Raulin, Jean-Pierre; Manninen, Jyrki; Correia, Emília; Turunen, Tauno; Magalhães, Antonio

    2017-12-01

    The daytime lower ionosphere behaves as a solar X-ray flare detector, which can be monitored using very low frequency (VLF) radio waves that propagate inside the Earth-ionosphere waveguide. In this paper, we infer the lower ionosphere sensitivity variation over a complete solar cycle by using the minimum X-ray fluence (FXmin) necessary to produce a disturbance of the quiescent ionospheric conductivity. FXmin is the photon energy flux integrated over the time interval from the start of a solar X-ray flare to the beginning of the ionospheric disturbance recorded as amplitude deviation of the VLF signal. FXmin is computed for ionospheric disturbances that occurred in the time interval of December-January from 2007 to 2016 (solar cycle 24). The computation of FXmin uses the X-ray flux in the wavelength band below 0.2 nm and the amplitude of VLF signals transmitted from France (HWU), Turkey (TBB), and U.S. (NAA), which were recorded in Brazil, Finland, and Peru. The main result of this study is that the long-term variation of FXmin is correlated with the level of solar activity, having FXmin values in the range (1 - 12) × 10-7 J/m2. Our result suggests that FXmin is anticorrelated with the lower ionosphere sensitivity, confirming that the long-term variation of the ionospheric sensitivity is anticorrelated with the level of solar activity. This result is important to identify the minimum X-ray fluence that an external source of ionization must overcome in order to produce a measurable ionospheric disturbance during daytime.

  20. High-sensitive portable ASE-2 X-ray analyzer of sulfur in mineral oil

    International Nuclear Information System (INIS)

    Anchugov, I.S.; Goganov, A.D.; Plotnikov, R.I.

    2007-01-01

    The high-sensitivity ASE-2 analyzer of sulfur on the basis of existing ASE-I device is designed. ASE-2 analyzer realizes a standard method of energy dispersion X-ray fluorescent determinations of a sulfur mass fraction in mineral oil and allows to carry out the quantitative determination of sulfur in hydrocarbonic raw material and fuel in a 0.002-5 mass.% range [ru

  1. AN EXTENDED AND MORE SENSITIVE SEARCH FOR PERIODICITIES IN ROSSI X-RAY TIMING EXPLORER/ALL-SKY MONITOR X-RAY LIGHT CURVES

    International Nuclear Information System (INIS)

    Levine, Alan M.; Bradt, Hale V.; Chakrabarty, Deepto; Corbet, Robin H. D.; Harris, Robert J.

    2011-01-01

    We present the results of a systematic search in ∼14 years of Rossi X-ray Timing Explorer All-Sky Monitor (ASM) data for evidence of periodicities. Two variations of the commonly used Fourier analysis search method have been employed to significantly improve upon the sensitivity achieved by Wen et al. in 2006, who also searched for periodicities in ASM data. In addition, the present search is comprehensive in terms of sources studied and frequency range covered, and has yielded the detection of the signatures of the orbital periods of eight low-mass X-ray binary systems and of ten high-mass X-ray binaries not listed in the tables of Wen et al. Orbital periods, epochs, signal amplitudes, modulation fractions, and folded light curves are given for each of these systems. Seven of the orbital periods are the most precise reported to date. In the course of this work, the 18.545 day orbital period of IGR J18483-0311 was co-discovered, and the first detections in X-rays were made of the ∼3.9 day orbital period of LMC X-1 and the ∼3.79 hr orbital period of 4U 1636-536. The results inform future searches for orbital and other periodicities in X-ray binaries.

  2. X-ray survival characteristics and genetic analysis for nine saccharomyces deletion mutants that show altered radiation sensitivity

    Energy Technology Data Exchange (ETDEWEB)

    Game, John C.; Williamson, Marsha S.; Baccari, Clelia

    2004-01-07

    The availability of a genome-wide set of Saccharomyces deletion mutants provides a chance to identify all the yeast genes involved in DNA repair. Using X-rays, we are screening these mutants to identify additional genes that show increased sensitivity to the lethal effects of ionizing radiation. For each mutant identified as sensitive, we are confirming that the sensitivity phenotype co-segregates with the deletion allele and are obtaining multipoint survival-versus-dose assays in at least two haploid and one homozygous diploid strains. We present data for deletion mutants involving the genes DOT1, MDM20, NAT3, SPT7, SPT20, GCN5, HFI1, DCC1 and VID21/EAF1, and discuss their potential roles in repair. Eight of these genes have a clear radiation-sensitive phenotype when deleted, but the ninth, GCN5, has at most a borderline phenotype. None of the deletions confer substantial sensitivity to ultra-violet radiation, although one or two may confer marginal sensitivity. The DOT1 gene is of interest because its only known function is to methylate one lysine residue in the core of the histone H3 protein. We find that histone H3 mutants (supplied by K. Struhl) in which this residue is replaced by other amino-acids are also X-ray sensitive, seeming to confirm that methylation of the lysine-79 residue is required for effective repair of radiation damage.

  3. Enhancement of molecular sensitivity in positron emission tomography with quantum correlation of γ-ray photons

    Science.gov (United States)

    Sato, K.; Kobayashi, Y.

    2015-05-01

    Enhancement of molecular sensitivity in positron emission tomography (PET) has long been discussed with respect to imaging instrumentation and algorithms for data treatment. Here, the molecular sensitivity in PET is discussed on the basis of 2-dimensional coincident measurements of 511 keV γ ray photons resultant from two-photon annihilation. Introduction of an additional selection window based on the energy sum and difference of the coincidently measured γ ray photons, without any significant instrumental and algorithmic changes, showed an improvement in the signal-to-noise ratio (SNR) by an order of magnitude. Improvement of performance characteristics in the PET imaging system was demonstrated by an increase in the noise equivalent count rate (NECR) which takes both the SNR and the detection efficiency into consideration. A further improvement of both the SNR and the NECR is expected for the present system in real clinical and in-vivo environments, where much stronger positron sources are employed.

  4. Enhancement of molecular sensitivity in positron emission tomography with quantum correlation of γ-ray photons

    International Nuclear Information System (INIS)

    Sato, K.; Kobayashi, Y.

    2015-01-01

    Enhancement of molecular sensitivity in positron emission tomography (PET) has long been discussed with respect to imaging instrumentation and algorithms for data treatment. Here, the molecular sensitivity in PET is discussed on the basis of 2-dimensional coincident measurements of 511 keV γ ray photons resultant from two-photon annihilation. Introduction of an additional selection window based on the energy sum and difference of the coincidently measured γ ray photons, without any significant instrumental and algorithmic changes, showed an improvement in the signal-to-noise ratio (SNR) by an order of magnitude. Improvement of performance characteristics in the PET imaging system was demonstrated by an increase in the noise equivalent count rate (NECR) which takes both the SNR and the detection efficiency into consideration. A further improvement of both the SNR and the NECR is expected for the present system in real clinical and in-vivo environments, where much stronger positron sources are employed

  5. Use of gamma-rays sensitivity for discrimination of upland cultivars of groups Indican and Japonica

    International Nuclear Information System (INIS)

    Rodrigues, Luis Roberto Franco

    2003-01-01

    Sixty-five upland rice cultivars (Oryza sativa L.) were evaluated in relation to gamma-ray sensitivity. Seeds were subjected to seven doses of gamma-radiation and sown in wooden boxes in randomised complete block design with three replications. The experiment was conducted in greenhouse during the year of 1992. Physiological effects caused by radiation in the M 1 generation, were evaluated. The results showed that the sensitivity to the radiation at doses 300 and 360 Gy was useful for distinguishing Indican and Japonica groups. (author)

  6. Enhanced gamma ray sensitivity in bismuth triiodide sensors through volumetric defect control

    International Nuclear Information System (INIS)

    Johns, Paul M.; Baciak, James E.; Nino, Juan C.

    2016-01-01

    Some of the more attractive semiconducting compounds for ambient temperature radiation detector applications are impacted by low charge collection efficiency due to the presence of point and volumetric defects. This has been particularly true in the case of BiI_3, which features very attractive properties (density, atomic number, band gap, etc.) to serve as a gamma ray detector, but has yet to demonstrate its full potential. We show that by applying growth techniques tailored to reduce defects, the spectral performance of this promising semiconductor can be realized. Gamma ray spectra from >100 keV source emissions are now obtained from high quality Sb:BiI_3 bulk crystals with limited concentrations of defects (point and extended). The spectra acquired in these high quality crystals feature photopeaks with resolution of 2.2% at 662 keV. Infrared microscopy is used to compare the local microstructure between radiation sensitive and non-responsive crystals. This work demonstrates that BiI_3 can be prepared in melt-grown detector-grade samples with superior quality and can acquire the spectra from a variety of gamma ray sources.

  7. Quality control of X-ray films with blue spectral sensitivity: comparative study

    International Nuclear Information System (INIS)

    Carrasco, F.; Ruiz Cruces, R.; Sendra, F.; Diez de los rios, A.

    1994-01-01

    In this work, seven X-ray films with blue-ultraviolet spectral sensitivity have been studied by means of light sensitometry, x-ray sensitometry and spatial resolution test. Three screens of different composition and speed were use. Only the films HPX44 and RG showed a high base plus for (>0,30), the remaining films maintained their values between 0,21 and 0,26. When blue light sensitometry was substituted by green light sensitometry, base plus fog practically did not show variations and gradient and speed changed less than 4% and 10% respectively. Speed and Gradient must be calculated from the relation between exposition and optical density, avoiding parameters referred to type optical density of a given step of the wedge. Two films with high speed (RG and HPX 44), four films with medium speed (Curix RP2, NewRX, Cronex 4 and X-Omat S) and one film with low speed but high resolution (Cronex 7) have been found. The obtained results present useful comparative data to select and adequate film according to the characteristic of the x-ray examination and the available screens. (Author)

  8. Proposed Diagnostic Criteria for Smartphone Addiction.

    Science.gov (United States)

    Lin, Yu-Hsuan; Chiang, Chih-Lin; Lin, Po-Hsien; Chang, Li-Ren; Ko, Chih-Hung; Lee, Yang-Han; Lin, Sheng-Hsuan

    2016-01-01

    Global smartphone penetration has led to unprecedented addictive behaviors. The aims of this study are to develop diagnostic criteria of smartphone addiction and to examine the discriminative ability and the validity of the diagnostic criteria. We developed twelve candidate criteria for characteristic symptoms of smartphone addiction and four criteria for functional impairment caused by excessive smartphone use. The participants consisted of 281 college students. Each participant was systematically assessed for smartphone-using behaviors by psychiatrist's structured diagnostic interview. The sensitivity, specificity, and diagnostic accuracy of the candidate symptom criteria were analyzed with reference to the psychiatrists' clinical global impression. The optimal model selection with its cutoff point of the diagnostic criteria differentiating the smartphone addicted subjects from non-addicted subjects was then determined by the best diagnostic accuracy. Six symptom criteria model with optimal cutoff point were determined based on the maximal diagnostic accuracy. The proposed smartphone addiction diagnostic criteria consisted of (1) six symptom criteria, (2) four functional impairment criteria and (3) exclusion criteria. Setting three symptom criteria as the cutoff point resulted in the highest diagnostic accuracy (84.3%), while the sensitivity and specificity were 79.4% and 87.5%, respectively. We suggested determining the functional impairment by two or more of the four domains considering the high accessibility and penetration of smartphone use. The diagnostic criteria of smartphone addiction demonstrated the core symptoms "impaired control" paralleled with substance related and addictive disorders. The functional impairment involved multiple domains provide a strict standard for clinical assessment.

  9. Proposed Diagnostic Criteria for Smartphone Addiction.

    Directory of Open Access Journals (Sweden)

    Yu-Hsuan Lin

    Full Text Available Global smartphone penetration has led to unprecedented addictive behaviors. The aims of this study are to develop diagnostic criteria of smartphone addiction and to examine the discriminative ability and the validity of the diagnostic criteria.We developed twelve candidate criteria for characteristic symptoms of smartphone addiction and four criteria for functional impairment caused by excessive smartphone use. The participants consisted of 281 college students. Each participant was systematically assessed for smartphone-using behaviors by psychiatrist's structured diagnostic interview. The sensitivity, specificity, and diagnostic accuracy of the candidate symptom criteria were analyzed with reference to the psychiatrists' clinical global impression. The optimal model selection with its cutoff point of the diagnostic criteria differentiating the smartphone addicted subjects from non-addicted subjects was then determined by the best diagnostic accuracy.Six symptom criteria model with optimal cutoff point were determined based on the maximal diagnostic accuracy. The proposed smartphone addiction diagnostic criteria consisted of (1 six symptom criteria, (2 four functional impairment criteria and (3 exclusion criteria. Setting three symptom criteria as the cutoff point resulted in the highest diagnostic accuracy (84.3%, while the sensitivity and specificity were 79.4% and 87.5%, respectively. We suggested determining the functional impairment by two or more of the four domains considering the high accessibility and penetration of smartphone use.The diagnostic criteria of smartphone addiction demonstrated the core symptoms "impaired control" paralleled with substance related and addictive disorders. The functional impairment involved multiple domains provide a strict standard for clinical assessment.

  10. Photovoltaic system criteria documents. Volume 3: Environmental issues and evaluation criteria for photovoltaic applications

    Science.gov (United States)

    Koenig, John C.; Billitti, Joseph W.; Tallon, John M.

    1979-01-01

    The environmental issues and evaluation criteria relating to the suitability of sites proposed for photovoltaic (PV) system deployment are identified. The important issues are defined, briefly discussed and then developed into evaluation criteria. System designers are provided with information on the environmental sensitivity of PV systems in realistic applications, background material which indicates the applicability of the siting issues identified, and evaluation criteria are defined to facilitate the selection of sites that maximize PV system operation.

  11. X-ray Sensitive Material

    Science.gov (United States)

    2015-12-01

    TM 8772 5 Literature reports on BiI3/nylon composites used X-ray sources with a Mo target (Reference 18) or magnesium target (Reference 19). However...1981. Pp. D-155 to D-160. 22. G. Pretzsch, B. Dorschel, and T. Schonmuth. IEEE Transactions on Electrical Insulation, Vol. EI -21, No.3, June 1986

  12. Assessing the efficiency position sensitive gaseous X-rays detectors

    International Nuclear Information System (INIS)

    Almeida, Gevaldo L. de; Souza, Maria Ines Silvani; Lopes, Ricardo T.

    2009-01-01

    Full text: The efficiency of gaseous X-ray detectors can be evaluated from tabulated data, but this approach assumes that the whole detector volume is permeated by the electrostatic field produced by the anode-cathode. Indeed, the usual detectors are comprised by a cylindrical hull acting as cathode containing a wire at its axis as anode, a configuration which foods the space between them with the electrostatic field. Some specially designed detectors, however, as Position Sensitive Detectors, contain regions which are not submitted to the electrostatic field, and hence, their efficiency could not be assessed from the tabulated data. Direct measurements of this efficiency would require a mono-chromator or set of pure mono-energetic X-rays sources. As only very few of them are really mono-energetic, the detector response to a given energy would be spoiled by to the concomitant contribution of other energies. Yet, the information would not be completely lost, but only concealed due to the convolution carried out by the detector. Therefore, a proper unfolding would be capable to recover the information, yielding the individual detector efficiency for each of the contributing energies. The degraded information is retrieved in this work through a proper mathematical unfolding of the detector response, when exposed to Bremsstrahlung spectra from an X-ray tube submitted to different voltages. For this purpose, Lorentzian functions have been fitted to these spectra - obtained with a NaI(Tl) spectrometer - in order to characterize them with proper parameters. The mathematical convolution of these functions with a theoretical detector efficiency curve yields, after integration, values which, confronted with those experimentally measured, allow the determination of the parameters of the efficiency curve. As some parameters of this curve are well known, it is possible to represent it by proper functions. For argon-filled detectors, for instance, this efficiency has a

  13. Analysis of the procedures and criteria for implantation of X-ray beams for ISO 4037 reference at low energies

    International Nuclear Information System (INIS)

    Figueiredo, Marcus Tadeu Tanuri de

    2012-01-01

    According to the radiological protection principles, practices involving ionizing radiation must be planned and carried out under the guarantee that the values of individual doses, the number of people exposed to radiation and the probability of accidental exposures are as low as reasonably achievable. Therefore, radiation dosimetry is required to be done with reliable instruments designed for measuring dosimetric quantities. The reliability of the dosimetry depends on both the calibration of the dosimeter and its proper performance under certain test conditions. The International Standardization Organization (ISO), in order to promote international standardization and metrological coherency, established sets of reference X-ray beams for dosimeter calibration and typing-test; they are expected to be implemented in metrology laboratories in compliance with specific technical requirements. At low energies there are specific requirements that need to be considered in both the implementation of the reference beams and their use in calibration and testing. The present study is an analysis of the procedures and criteria for ISO 4037 reference radiation implementation, at low energies. In the Dosimeter Calibration Laboratory of the Development Center of Nuclear Technology (LCD / CDTN), experiments were performed for determining the X-ray reference radiation parameters. Alternatives to the usual methods for half-value layer determination were studied. Spectra of reference beams were simulated with software and compared with experimental measurements. Different climatic conditions were reproduced in the Laboratory for analysis of its influence on the determination of the beam parameters. Uncertainties in the measurements of studied parameters were evaluated. According to the ISO 4037 criteria, the low energy X-ray beams were considered to be implemented; they allowed the determination of the conversion coefficients from air kerma to the operational radiation protection

  14. Influence of skew rays on the sensitivity and signal-to-noise ratio of a fiber-optic surface-plasmon-resonance sensor: a theoretical study

    International Nuclear Information System (INIS)

    Dwivedi, Yogendra S.; Sharma, Anuj K.; Gupta, Banshi D.

    2007-01-01

    We have theoretically analyzed the influence of skew rays on the performance of a fiber-optic sensor based on surface plasmon resonance. The performance of the sensor has been evaluated in terms of its sensitivity and signal-to-noise ratio (SNR). The theoretical model for skewness dependence includes the material dispersion in fiber cores and metal layers, simultaneous excitation of skew rays, and meridional rays in the fiber core along with all guided rays launching from a collimated light source. The effect of skew rays on the SNR and the sensitivity of the sensor with two different metals has been compared. The same comparison is carried out for the different values of design parameters such as numerical aperture, fiber core diameter, and the length of the surface-plasmon-resonance (SPR)active sensing region. This detailed analysis for the effect of skewness on the SNR and the sensitivity of the sensor leads us to achieve the best possible performance from a fiber-optic SPR sensor against the skewness in the optical fiber

  15. Soft x-ray streak camera for laser fusion applications

    International Nuclear Information System (INIS)

    Stradling, G.L.

    1981-04-01

    This thesis reviews the development and significance of the soft x-ray streak camera (SXRSC) in the context of inertial confinement fusion energy development. A brief introduction of laser fusion and laser fusion diagnostics is presented. The need for a soft x-ray streak camera as a laser fusion diagnostic is shown. Basic x-ray streak camera characteristics, design, and operation are reviewed. The SXRSC design criteria, the requirement for a subkilovolt x-ray transmitting window, and the resulting camera design are explained. Theory and design of reflector-filter pair combinations for three subkilovolt channels centered at 220 eV, 460 eV, and 620 eV are also presented. Calibration experiments are explained and data showing a dynamic range of 1000 and a sweep speed of 134 psec/mm are presented. Sensitivity modifications to the soft x-ray streak camera for a high-power target shot are described. A preliminary investigation, using a stepped cathode, of the thickness dependence of the gold photocathode response is discussed. Data from a typical Argus laser gold-disk target experiment are shown

  16. Sensitivity analysis of high resolution gamma-ray detection for safeguards monitoring at natural uranium conversion facilities

    Energy Technology Data Exchange (ETDEWEB)

    Dewji, S.A., E-mail: dewjisa@ornl.gov [Oak Ridge National Laboratory, PO Box 2008 MS-6335, Oak Ridge TN 37831 (United States); Georgia Institute of Technology, 770 State Street, Atlanta, GA 30332-0745 (United States); Croft, S. [Oak Ridge National Laboratory, PO Box 2008 MS-6335, Oak Ridge TN 37831 (United States); Hertel, N.E. [Oak Ridge National Laboratory, PO Box 2008 MS-6335, Oak Ridge TN 37831 (United States); Georgia Institute of Technology, 770 State Street, Atlanta, GA 30332-0745 (United States)

    2017-03-11

    Under the policies proposed by recent International Atomic Energy Agency (IAEA) circulars and policy papers, implementation of safeguards exists when any purified aqueous uranium solution or uranium oxides suitable for isotopic enrichment or fuel fabrication exists. Under IAEA Policy Paper 18, the starting point for nuclear material under safeguards was reinterpreted, suggesting that purified uranium compounds should be subject to safeguards procedures no later than the first point in the conversion process. In response to this technical need, a combination of simulation models and experimental measurements were employed in previous work to develop and validate gamma-ray nondestructive assay monitoring systems in a natural uranium conversion plant (NUCP). In particular, uranyl nitrate (UO{sub 2}(NO{sub 3}){sub 2}) solution exiting solvent extraction was identified as a key measurement point (KMP). Passive nondestructive assay techniques using high resolution gamma-ray spectroscopy were evaluated to determine their viability as a technical means for drawing safeguards conclusions at NUCPs, and if the IAEA detection requirements of 1 significant quantity (SQ) can be met in a timely manner. Building upon the aforementioned previous validation work on detector sensitivity to varying concentrations of uranyl nitrate via a series of dilution measurements, this work investigates detector response parameter sensitivities to gamma-ray signatures of uranyl nitrate. The full energy peak efficiency of a detection system is dependent upon the sample, geometry, absorption, and intrinsic efficiency parameters. Perturbation of these parameters translates into corresponding variations of the 185.7 keV peak area of the {sup 235}U in uranyl nitrate. Such perturbations in the assayed signature impact the quality or versatility of the safeguards conclusions drawn. Given the potentially high throughput of uranyl nitrate in NUCPs, the ability to assay 1 SQ of material requires

  17. Radio-sensitization of esophageal cancer EC9706 cells to X ray by histone deacetylase inhibiter Trichostatin A

    International Nuclear Information System (INIS)

    Lin Xiaoli; Qin Guangyong; Fang Huasheng; Zhang Fengqiu; Ya Huiyuan

    2009-01-01

    Cell apoptosis and the expression of DNA damage repair-related genes XRCC2, ATM and Lig4 were detected separately by flow cytometry analysis and real-time fluorescence quantitative (RT-PCR), in order to investigate the effect of Trichostatin A (TSA) pre-treatment on the radiosensitivity of esophageal cancer EC9706 cells to X ray in vitro. The results indicate that pre-irradiation exposure to TSA enhances cell apoptotic rate by X ray markedly (P<0.05) and the mRNA levels of XRCC2, ATM and Lig4 (except 8Gy) are up-regulated by X ray individually (P<0.05). TSA alone and TSA in combination with X ray all reduce mRNA levels of XRCC2, ATM and Lig4. In conclusions, TSA may radio-sensitize EC9706 cells to X ray by reducing mRNA levels of XRCC2, ATM and Lig4. (authors)

  18. Carotid Consensus Panel duplex criteria can replace modified University of Washington criteria without affecting accuracy.

    Science.gov (United States)

    Kim, Ann H; Augustin, Gener; Shevitz, Andrew; Kim, Hannah; Trivonovich, Michael R; Powell, Alexis R; Kumins, Norman; Tarr, Robert; Kashyap, Vikram S

    2018-04-01

    The decision to intervene for internal carotid stenosis often depends on the degree of stenosis seen on duplex ultrasound (US). The aim of this study is to compare the diagnostic accuracy of two criteria: modified University of Washington (UW) and 2003 Carotid Consensus Panel (CCP). All patients undergoing US in an accredited (IAC) vascular laboratory from January 2010 to June 2015 were reviewed ( n=18,772 US exams). Patients receiving a neck computed tomography angiography (CTA) within 6 months of the US were included in the study ( n=254). The degree of stenosis was determined by UW/CCP criteria and confirmed on CTA images using North American Symptomatic Carotid Endarterectomy Trial (NASCET)/European Carotid Surgery Trial (ECST) schema. Kappa analysis with 95% confidence intervals (CIs) were utilized to determine duplex-CTA agreement. A total of 417 carotid arteries from 221 patients were assessed in this study. The modified UW criteria accurately classified 266 (63.9%, kappa = 0.321, 95% CI 0.255 to 0.386) cases according to NASCET-derived measurements. The sensitivity, specificity, and accuracy at ≥ 60% stenosis were 65.7%, 81.3%, and 81.9%. The CCP criteria resulted in 296 (70.9%) accurate diagnoses (kappa = 0.359, 95% CI 0.280 to 0.437). At ≥ 70% stenosis, the sensitivity, specificity and accuracy were 38.8%, 91.6%, and 87.1% for NASCET. Comparison of the duplex results to ECST-derived CTA measurements revealed a similar trend (UW 53.1%, κ = 0.301 vs CCP 62.1%, κ = 0.315). The CCP criteria demonstrate a higher concordance rate with measurements taken from CTAs. The CCP criteria may be more sensitive in classifying clinically significant degrees of stenosis without a loss in diagnostic accuracy.

  19. Evaluation and construction of diagnostic criteria for inclusion body myositis

    Science.gov (United States)

    Mammen, Andrew L.; Amato, Anthony A.; Weiss, Michael D.; Needham, Merrilee

    2014-01-01

    Objective: To use patient data to evaluate and construct diagnostic criteria for inclusion body myositis (IBM), a progressive disease of skeletal muscle. Methods: The literature was reviewed to identify all previously proposed IBM diagnostic criteria. These criteria were applied through medical records review to 200 patients diagnosed as having IBM and 171 patients diagnosed as having a muscle disease other than IBM by neuromuscular specialists at 2 institutions, and to a validating set of 66 additional patients with IBM from 2 other institutions. Machine learning techniques were used for unbiased construction of diagnostic criteria. Results: Twenty-four previously proposed IBM diagnostic categories were identified. Twelve categories all performed with high (≥97%) specificity but varied substantially in their sensitivities (11%–84%). The best performing category was European Neuromuscular Centre 2013 probable (sensitivity of 84%). Specialized pathologic features and newly introduced strength criteria (comparative knee extension/hip flexion strength) performed poorly. Unbiased data-directed analysis of 20 features in 371 patients resulted in construction of higher-performing data-derived diagnostic criteria (90% sensitivity and 96% specificity). Conclusions: Published expert consensus–derived IBM diagnostic categories have uniformly high specificity but wide-ranging sensitivities. High-performing IBM diagnostic category criteria can be developed directly from principled unbiased analysis of patient data. Classification of evidence: This study provides Class II evidence that published expert consensus–derived IBM diagnostic categories accurately distinguish IBM from other muscle disease with high specificity but wide-ranging sensitivities. PMID:24975859

  20. A cell for extended x-ray absorption fine structure studies of oxygen sensitive products of redox reactions

    International Nuclear Information System (INIS)

    Furenlid, L.R.; Renner, M.W.; Fajer, J.

    1990-01-01

    We describe a cell suitable for extended x-ray absorption fine structure (EXAFS) studies of oxygen and/or water sensitive products of redox reactions. The cell utilizes aluminized Mylar windows that are transparent to x rays, provide low gas permeability, and allow vacuum to be maintained in the cell. The windows are attached to the glassware with an epoxy that resists attack by common organic solvents. Additional side arms allow multiple spectroscopic probes of the same sample under anaerobic and anhydrous conditions

  1. Method and apparatus for enhanced sensitivity filmless medical x-ray imaging, including three-dimensional imaging

    Science.gov (United States)

    Parker, Sherwood

    1995-01-01

    A filmless X-ray imaging system includes at least one X-ray source, upper and lower collimators, and a solid-state detector array, and can provide three-dimensional imaging capability. The X-ray source plane is distance z.sub.1 above upper collimator plane, distance z.sub.2 above the lower collimator plane, and distance z.sub.3 above the plane of the detector array. The object to be X-rayed is located between the upper and lower collimator planes. The upper and lower collimators and the detector array are moved horizontally with scanning velocities v.sub.1, v.sub.2, v.sub.3 proportional to z.sub.1, z.sub.2 and z.sub.3, respectively. The pattern and size of openings in the collimators, and between detector positions is proportional such that similar triangles are always defined relative to the location of the X-ray source. X-rays that pass through openings in the upper collimator will always pass through corresponding and similar openings in the lower collimator, and thence to a corresponding detector in the underlying detector array. Substantially 100% of the X-rays irradiating the object (and neither absorbed nor scattered) pass through the lower collimator openings and are detected, which promotes enhanced sensitivity. A computer system coordinates repositioning of the collimators and detector array, and X-ray source locations. The computer system can store detector array output, and can associate a known X-ray source location with detector array output data, to provide three-dimensional imaging. Detector output may be viewed instantly, stored digitally, and/or transmitted electronically for image viewing at a remote site.

  2. A high count rate one-dimensional position sensitive detector and a data acquisition system for time resolved X-ray scattering studies

    International Nuclear Information System (INIS)

    Pernot, P.

    1982-01-01

    A curved multiwire proportional drift chamber has been built as a general purpose instrument for X-ray scattering and X-ray diffraction experiments with synchrotron radiation. This parallaxe-free one-dimensional linear position sensitive detector has a parallel readout with a double hit logic. The data acquisition system, installed as a part of the D11 camera at LURE-DCI, is designed to perform time slicing and cyclic experiments; it has been used with either the fast multiwire chamber or a standard position sensitive detector with delay line readout [fr

  3. Highly sensitive x-ray detectors in the low-energy range on n-type 4H-SiC epitaxial layers

    Energy Technology Data Exchange (ETDEWEB)

    Mandal, Krishna C.; Muzykov, Peter G. [Department of Electrical Engineering, University of South Carolina, Columbia, South Carolina 29208 (United States); Russell Terry, J. [Space Science and Applications Group (ISR-1), Intelligence and Space Research Division, Los Alamos National Laboratory, Los Alamos, New Mexico 87545 (United States)

    2012-07-30

    Schottky diodes on n-type 4H-SiC epitaxial layers have been fabricated for low-energy x-ray detection. The detectors were highly sensitive to soft x-rays and showed improved response compared to the commercial SiC UV photodiodes. Current-voltage characteristics at 475 K showed low leakage current revealing the possibility of high temperature operation. The high quality of the epi-layer was confirmed by x-ray diffraction and chemical etching. Thermally stimulated current measurements performed at 94-550 K revealed low density of deep levels which may cause charge trapping. No charge trapping on detectors' responsivity in the low x-ray energy was found.

  4. Cross-sensitivity of X-ray-hypersensitive cells derived from LEC strain rats to DNA-damaging agents

    International Nuclear Information System (INIS)

    Okui, T.; Endoh, D.; Arai, S.; Isogai, E.; Hayashi, M.

    1996-01-01

    The cross-sensitivity of X-ray-hypersensitive lung fibroblasts from LEC strain (LEC) rats to other DNA-damaging agents was examined. The LEC cells were 2- to 3-fold more sensitive to bleomycin (BLM) that induces DNA double-strand breaks, and to a cross-linking agent, mitomycin C, than the cells from WKAH strain (WKAH) rats, while they were slightly sensitive to alkylating agents, ethyl nitrosourea and N-methyl-N'-nitro-N-nitrosoguanidine, but not to UV-irradiation. Although no difference was observed in the initial yields of DNA double-strand breaks induced by BLM between LEC and WKAH cells, the repair process of DNA double-strand breaks was significantly slower in LEC cells than in WKAH cells

  5. Application of a one-dimensional position-sensitive detector to a Kratky small-angle x-ray camera

    International Nuclear Information System (INIS)

    Russell, T.P.; Stein, R.S.; Kopp, M.K.; Zedler, R.E.; Hendricks, R.W.; Lin, J.S.

    1979-01-01

    A conventional Kratky small-angle collimation system has been modified to allow the use of a one-dimensional position-sensitive x-ray detector. The detector was designed specifically for use with a long-slit camera and has uniform sensitivity over the entire beam in the slit-length direction. Procedures for alignment of the collimation system are given, and a variety of tests of the performance of the system are presented. Among the latter are measurements of electronic noise and parasitic scattering as well as comparisons against samples which were also measured on other cameras. The good agreement of these comparisons demonstrates the success of the use of a position-sensitive detector with the Kratky collimation system

  6. Application of a one-dimensional position-sensitive detector to a Kratky small-angle x-ray camera

    Energy Technology Data Exchange (ETDEWEB)

    Russell, T.P.; Stein, R.S.; Kopp, M.K.; Zedler, R.E.; Hendricks, R.W.; Lin, J.S.

    1979-01-01

    A conventional Kratky small-angle collimation system has been modified to allow the use of a one-dimensional position-sensitive x-ray detector. The detector was designed specifically for use with a long-slit camera and has uniform sensitivity over the entire beam in the slit-length direction. Procedures for alignment of the collimation system are given, and a variety of tests of the performance of the system are presented. Among the latter are measurements of electronic noise and parasitic scattering as well as comparisons against samples which were also measured on other cameras. The good agreement of these comparisons demonstrates the success of the use of a position-sensitive detector with the Kratky collimation system.

  7. Assessment of five different guideline indication criteria for spirometry, including modified GOLD criteria, in order to detect COPD: data from 5,315 subjects in the PLATINO study.

    Science.gov (United States)

    Luize, Ana P; Menezes, Ana Maria B; Perez-Padilla, Rogelio; Muiño, Adriana; López, Maria Victorina; Valdivia, Gonzalo; Lisboa, Carmem; Montes de Oca, Maria; Tálamo, Carlos; Celli, Bartolomé; Nascimento, Oliver A; Gazzotti, Mariana R; Jardim, José R

    2014-10-30

    Spirometry is the gold standard for diagnosing chronic obstructive pulmonary disease (COPD). Although there are a number of different guideline criteria for deciding who should be selected for spirometric screening, to date it is not known which criteria are the best based on sensitivity and specificity. Firstly, to evaluate the proportion of subjects in the PLATINO Study that would be recommended for spirometry testing according to Global initiative for Obstructive Lung Disease (GOLD)-modified, American College of Chest Physicians (ACCP), National Lung Health Education Program (NLHEP), GOLD and American Thoracic Society/European Respiratory Society (ATS/ERS) criteria. Secondly, we aimed to compare the sensitivity, specificity, and positive predictive and negative predictive values, of these five different criteria. Data from the PLATINO study included information on respiratory symptoms, smoking and previous spirometry testing. The GOLD-modified spirometry indication criteria are based on three positive answers out of five questions: the presence of cough, phlegm in the morning, dyspnoea, age over 40 years and smoking status. Data from 5,315 subjects were reviewed. Fewer people had an indication for spirometry (41.3%) according to the GOLD-modified criteria, and more people had an indication for spirometry (80.4%) by the GOLD and ATS/ERS criteria. A low percentage had previously had spirometry performed: GOLD-modified (14.5%); ACCP (13.2%); NLHEP (12.6%); and GOLD and ATS/ERS (12.3%). The GOLD-modified criteria showed the least sensitivity (54.9) and the highest specificity (61.0) for detecting COPD, whereas GOLD and ATS/ERS criteria showed the highest sensitivity (87.9) and the least specificity (20.8). There is a considerable difference in the indication for spirometry according to the five different guideline criteria. The GOLD-modified criteria recruit less people with the greatest sum of sensitivity and specificity.

  8. Design and performance of a soft-x-ray interferometer for ultra-high-resolution fourier transform spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Moler, E.J.; Hussain, Z.; Duarte, R.M.; Howells, M.R. [Lawrence Berkeley National Lab., CA (United States)

    1997-04-01

    A Fourier Transform Soft X-ray spectrometer (FT-SX) has been designed and is under construction for the Advanced Light Source (ALS) at Lawrence Berkeley National Laboratory as a branch of beamline 9.3.2. The spectrometer is a novel soft x-ray interferometer designed for ultra-high resolution (theoretical resolving power E/{delta}E{approximately}10{sup 6}) spectroscopy in the photon energy region of 60-120 eV. This instrument is expected to provide experimental results which sensitively test models of correlated electron processes in atomic and molecular physics. The design criteria and consequent technical challenges posed by the short wavelengths of x-rays and desired resolving power are discussed. The fundamental and practical aspects of soft x-ray interferometry are also explored.

  9. Portable X-ray fluorescence analyzer of high sensitivity using X-ray tube excitation

    International Nuclear Information System (INIS)

    Vatai, E.; Ando, L.

    1982-01-01

    A review of the three main methods of X-ray fluorescence analysis and their problems is given. The attainable accuracy and effectiveness of each method are discussed. The main properties of portable X-ray analyzers required by the industry are described. The results and experiences of R and D activities in ATOMKI (Debrecen, Hungary) for developing portable X-ray analyzers are presented. The only way for increasing the accuracy and decreasing the measuring time is the application of X-ray tube excitation instead of radioactive sources. The new ATOMKI equipment presently under construction and patenting uses X-ray tube excitation; it will increase the accuracy of concentration determination by one order of magnitude. (D.Gy.)

  10. Pharmacologic requirements for obtaining sensitization of human tumor cells in vitro to combined 5-fluorouracil or ftorafur and x rays

    International Nuclear Information System (INIS)

    Byfield, J.E.; Calabro-Jones, P.; Klisak, I.; Kulhanian, F.

    1982-01-01

    The combined effects of X ray and 5-fluorouracil (5-FU) in tissue culture have been studied using two human adenocarcinoma lines (HeLa and HT-29 cells). Both showed similar sensitivities to 5-FU, HeLa cells appearing somewhat more resistant to higher concentrations. Combined treatment of both cell types with 5-FU and X rays led to a time-dependent enhancement of cell killing (''radiosensitization''). Only post-radiation incubation had any effect, prior exposure to 5-FU being strictly additive. Enhanced cell killing by combined 5-FU and X rays could not be explained by either the infliction of additional acute damage in the immediate post-radiation period or an inhibitory effect of 5-FU on the repair of sub-lethal X ray injury. Rather, the enhanced cytotoxicity proved to be dependent on a damage expressed in time periods exceeding the duration of a cell doubling time in vitro. Overall, the data equally suggest that X rays may sensitize the cells to 5-FU. The enhanced cell killing is maximized if the cells are continuously exposed to 5-FU for 48 hours following the X ray exposure. These results indicate that clinical treatment regimens might be useful in evaluating 5-FU infusional scheduling in accordance with these unique requirements, which are not met by conventional bolus 5-FU and X ray therapy fractionation regimens. Ftorafur, a drug proposed to act as a slow release form of 5-FU, was found to show limited cytotoxic potential in vitro and did not significantly enhance cell killing after X ray exposure

  11. High sensitivity phase retrieval method in grating-based x-ray phase contrast imaging

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Zhao; Gao, Kun; Chen, Jian; Wang, Dajiang; Wang, Shenghao; Chen, Heng; Bao, Yuan; Shao, Qigang; Wang, Zhili, E-mail: wangnsrl@ustc.edu.cn [National Synchrotron Radiation Laboratory, University of Science and Technology of China, Hefei 230029 (China); Zhang, Kai [Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049 (China); Zhu, Peiping; Wu, Ziyu, E-mail: wuzy@ustc.edu.cn [National Synchrotron Radiation Laboratory, University of Science and Technology of China, Hefei 230029, China and Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049 (China)

    2015-02-15

    Purpose: Grating-based x-ray phase contrast imaging is considered as one of the most promising techniques for future medical imaging. Many different methods have been developed to retrieve phase signal, among which the phase stepping (PS) method is widely used. However, further practical implementations are hindered, due to its complex scanning mode and high radiation dose. In contrast, the reverse projection (RP) method is a novel fast and low dose extraction approach. In this contribution, the authors present a quantitative analysis of the noise properties of the refraction signals retrieved by the two methods and compare their sensitivities. Methods: Using the error propagation formula, the authors analyze theoretically the signal-to-noise ratios (SNRs) of the refraction images retrieved by the two methods. Then, the sensitivities of the two extraction methods are compared under an identical exposure dose. Numerical experiments are performed to validate the theoretical results and provide some quantitative insight. Results: The SNRs of the two methods are both dependent on the system parameters, but in different ways. Comparison between their sensitivities reveals that for the refraction signal, the RP method possesses a higher sensitivity, especially in the case of high visibility and/or at the edge of the object. Conclusions: Compared with the PS method, the RP method has a superior sensitivity and provides refraction images with a higher SNR. Therefore, one can obtain highly sensitive refraction images in grating-based phase contrast imaging. This is very important for future preclinical and clinical implementations.

  12. High sensitivity phase retrieval method in grating-based x-ray phase contrast imaging

    International Nuclear Information System (INIS)

    Wu, Zhao; Gao, Kun; Chen, Jian; Wang, Dajiang; Wang, Shenghao; Chen, Heng; Bao, Yuan; Shao, Qigang; Wang, Zhili; Zhang, Kai; Zhu, Peiping; Wu, Ziyu

    2015-01-01

    Purpose: Grating-based x-ray phase contrast imaging is considered as one of the most promising techniques for future medical imaging. Many different methods have been developed to retrieve phase signal, among which the phase stepping (PS) method is widely used. However, further practical implementations are hindered, due to its complex scanning mode and high radiation dose. In contrast, the reverse projection (RP) method is a novel fast and low dose extraction approach. In this contribution, the authors present a quantitative analysis of the noise properties of the refraction signals retrieved by the two methods and compare their sensitivities. Methods: Using the error propagation formula, the authors analyze theoretically the signal-to-noise ratios (SNRs) of the refraction images retrieved by the two methods. Then, the sensitivities of the two extraction methods are compared under an identical exposure dose. Numerical experiments are performed to validate the theoretical results and provide some quantitative insight. Results: The SNRs of the two methods are both dependent on the system parameters, but in different ways. Comparison between their sensitivities reveals that for the refraction signal, the RP method possesses a higher sensitivity, especially in the case of high visibility and/or at the edge of the object. Conclusions: Compared with the PS method, the RP method has a superior sensitivity and provides refraction images with a higher SNR. Therefore, one can obtain highly sensitive refraction images in grating-based phase contrast imaging. This is very important for future preclinical and clinical implementations

  13. Porous silicon: X-rays sensitivity

    International Nuclear Information System (INIS)

    Gerstenmayer, J.L.; Vibert, Patrick; Mercier, Patrick; Rayer, Claude; Hyvernage, Michel; Herino, Roland; Bsiesy, Ahmad

    1994-01-01

    We demonstrate that high porosity anodically porous silicon is radioluminescent. Interests of this study are double. Firstly: is the construction of porous silicon X-rays detectors (imagers) possible? Secondly: is it necessary to protect silicon porous based optoelectronic systems from ionising radiations effects (spatial environment)? ((orig.))

  14. A microprogrammable high-speed data collection system for position sensitive X-ray detectors

    International Nuclear Information System (INIS)

    Hashizume, H.

    1984-01-01

    A high-speed data acquisition system has been designed which collects digital data from one- and two-dimensional position sensitive X-ray detectors at a maximum average data rate of 1 MHz. The system consists of two separate fast buffer memories, a 64 K word by 20-bit main storage, two timers, a display controller, a computer interface and a keyboard, controlled by a specially designed microprogrammable microprocessor. Data collection is performed by executing a microprogram stored in the control storage; data coming from a detector are first accumulated in a small but fast buffer memory by hardware and transferred to the main storage under control of the microprogram. This design not only permits time-resolved data collections but also provides maximum speed, flexibility and cost-effectiveness simultaneously. The system also accepts data from integrated detectors such as TV cameras. The system has been designed for use in experiments at conventional and synchrotron X-ray sources. (orig.)

  15. Development of EPSILON. A gamma ray imaging system for the nuclear industry

    International Nuclear Information System (INIS)

    Durrant, P.T.

    1999-06-01

    In recent years, much effort has been focused on the need to characterise, stabilise, decontaminate and eventually decommission radioactively contaminated nuclear facilities. These tasks can be complex and hazardous and are often hampered by a lack of knowledge of the nature and distribution of the contamination. A gamma-ray imaging system, capable of remotely mapping a contaminated scene, could be a useful tool in many tasks related to the decommissioning of nuclear facilities. This thesis describes and discusses the design, development, commissioning and characterisation of EPSILON, a multipurpose gamma-ray imaging system designed to meet the needs of a range of applications in the nuclear industry. Following a review of the range of potential applications and a critical assessment of the imaging systems available at the time, a set of design criteria for a multi-purpose gamma-ray imaging system are identified. The design and development of an imaging system to meet these criteria is described in detail. Suitable image-formation techniques are discussed and a pinhole collimator selected as the most appropriate. Consideration is given to the use of a scintillator-photodiode array as the imager detection plane but this option is rejected in favour of a position-sensitive photomultiplier tube (PSPMT). The development of two data-acquisition systems is described and comparisons made between the performance of these two techniques. The factors affecting the performance and image quality of this pinhole imaging system are discussed and a prototype design presented for a well-shielded, high-sensitivity imager. Experimental results obtained with this prototype are presented. These results demonstrate a good angular resolution of 1.6 deg across a 12.8 deg FOV and a factor of 7 improvement in sensitivity over a comparable resolution, single-pixel scanning-system. The spectral resolution of this prototype imager did not meet the design criteria. A modified design is

  16. A New High-sensitivity solar X-ray Spectrophotometer SphinX:early operations and databases

    Science.gov (United States)

    Gburek, Szymon; Sylwester, Janusz; Kowalinski, Miroslaw; Siarkowski, Marek; Bakala, Jaroslaw; Podgorski, Piotr; Trzebinski, Witold; Plocieniak, Stefan; Kordylewski, Zbigniew; Kuzin, Sergey; Farnik, Frantisek; Reale, Fabio

    The Solar Photometer in X-rays (SphinX) is an instrument operating aboard Russian CORONAS-Photon satellite. A short description of this unique instrument will be presented and its unique capabilities discussed. SphinX is presently the most sensitive solar X-ray spectrophotometer measuring solar spectra in the energy range above 1 keV. A large archive of SphinX mea-surements has already been collected. General access to these measurements is possible. The SphinX data repositories contain lightcurves, spectra, and photon arrival time measurements. The SphinX data cover nearly continuously the period since the satellite launch on January 30, 2009 up to the end-of November 2009. Present instrument status, data formats and data access methods will be shown. An overview of possible new science coming from SphinX data analysis will be discussed.

  17. Novel X-ray telescopes for wide-field X-ray monitoring

    International Nuclear Information System (INIS)

    Hudec, R.; Inneman, A.; Pina, L.; Sveda, L.

    2005-01-01

    We report on fully innovative very wide-field of view X-ray telescopes with high sensitivity as well as large field of view. The prototypes are very promising, allowing the proposals for space projects with very wide-field Lobster-eye X-ray optics to be considered. The novel telescopes will monitor the sky with unprecedented sensitivity and angular resolution of order of 1 arcmin. They are expected to contribute essentially to study and to understand various astrophysical objects such as AGN, SNe, Gamma-ray bursts (GRBs), X-ray flashes (XRFs), galactic binary sources, stars, CVs, X-ray novae, various transient sources, etc. The Lobster optics based X-ray All Sky Monitor is capable to detect around 20 GRBs and 8 XRFs yearly and this will surely significantly contribute to the related science

  18. Diagnostic criteria for headache attributed to temporomandibular disorders.

    Science.gov (United States)

    Schiffman, Eric; Ohrbach, Richard; List, Thomas; Anderson, Gary; Jensen, Rigmor; John, Mike T; Nixdorf, Donald; Goulet, Jean-Paul; Kang, Wenjun; Truelove, Ed; Clavel, Al; Fricton, James; Look, John

    2012-07-01

    We assessed and compared the diagnostic accuracy of two sets of diagnostic criteria for headache secondary to temporomandibular disorders (TMD). In 373 headache subjects with TMD, a TMD headache reference standard was defined as: self-reported temple headache, consensus diagnosis of painful TMD and replication of the temple headache using TMD-based provocation tests. Revised diagnostic criteria for Headache attributed to TMD were selected using the RPART (recursive partitioning and regression trees) procedure, and refined in half of the data set. Using the remaining half of the data, the diagnostic accuracy of the revised criteria was compared to that of the International Headache Society's International Classification of Headache Diseases (ICHD)-II criteria A to C for Headache or facial pain attributed to temporomandibular joint (TMJ) disorder. Relative to the TMD headache reference standard, ICHD-II criteria showed sensitivity of 84% and specificity of 33%. The revised criteria for Headache attributed to TMD had sensitivity of 89% with improved specificity of 87% (p headache that is changed with jaw movement, function or parafunction and (2) provocation of that headache by temporalis muscle palpation or jaw movement. Having significantly better specificity than the ICHD-II criteria A to C, the revised criteria are recommended to diagnose headache secondary to TMD.

  19. X-ray induced dominant lethal mutations in mature and immature oocytes of guinea-pigs and golden hamsters

    International Nuclear Information System (INIS)

    Cox, B.D.; Lyon, M.F.

    1975-01-01

    The induction of dominant lethal mutations by doses of 100-400 rad X-rays in oocytes of the guinea-pig and golden hamster was studied using criteria of embryonic mortality. For both species higher yields were obtained from mature than from immature oocytes. Data on fertility indicated that in the golden hamster immature oocytes were more sensitive to killing by X-rays than mature oocytes but that the converse was true in the guinea-pig. The dose-response relationship for mutation to dominant lethals in pre-ovulatory oocytes of guinea-pigs and golden hamsters was linear, both when based on pre- and post-implantation loss only. The rate per unit dose was higher for the golden hamster, and the old golden hamsters were possibly slightly more sensitive than young ones

  20. 9-β-arabinofuranosyladenine preferentially sensitizes radioresistant squamous cell carcinoma cell lines to x-rays

    International Nuclear Information System (INIS)

    Heaton, D.

    1992-06-01

    The effect of 9-β-arabinofuranosyladenine (ara-A) on sensitivity to the deleterious effects of x-rays was studied in six squamous cell carcinoma cell lines. Three lines were relatively radioresistant, having D 0 values of 2.31 to 2.89 Gy, and the other three lines were relatively radiosensitive, having D 0 values of between 1.07 and 1.45 Gy. Ara-A (50 or 500 μM) was added to cultures 30 min prior to irradiation and removed 30 min after irradiation, and sensitivity was measured in terms of cell survival. The radiosensitizing effect of ara-A was very dependent on the inherent radiosensitivity of the tumor cell line. Fifty micromolar concentrations of ara-A sensitized only the two most radioresistant lines, SCC-12B.2 and JSQ-3. Five hundred micromolar concentrations of ara-A sensitized the more sensitive cell lines, SQ-20B and SQ-9G, but failed to have any effect on the radiation response of the two most sensitive cell lines, SQ-38 and SCC-61. Concentrations of ara-A as low as 10 μM were equally efficient in inhibiting DNA synthesis in all six cell lines. These results suggest that the target for the radiosensitizing effect of ara-A is probably related to the factor controlling the inherent radiosensitivity of human tumor cells. Therefore, ara-A might be useful in overcoming radiation resistance in vivo

  1. 9-{beta}-arabinofuranosyladenine preferentially sensitizes radioresistant squamous cell carcinoma cell lines to x-rays

    Energy Technology Data Exchange (ETDEWEB)

    Heaton, D. [Rush Univ. Medical Center, Chicago, IL (United States). Therapeutic Radiology; Mustafi, R. [Chicago Univ., IL (United States). Dept. of Radiation and Cellular Oncology; Schwartz, J.L. [Chicago Univ., IL (United States). Dept. of Radiation and Cellular Oncology]|[Argonne National Lab., IL (United States)

    1992-06-01

    The effect of 9-{beta}-arabinofuranosyladenine (ara-A) on sensitivity to the deleterious effects of x-rays was studied in six squamous cell carcinoma cell lines. Three lines were relatively radioresistant, having D{sub 0} values of 2.31 to 2.89 Gy, and the other three lines were relatively radiosensitive, having D{sub 0} values of between 1.07 and 1.45 Gy. Ara-A (50 or 500 {mu}M) was added to cultures 30 min prior to irradiation and removed 30 min after irradiation, and sensitivity was measured in terms of cell survival. The radiosensitizing effect of ara-A was very dependent on the inherent radiosensitivity of the tumor cell line. Fifty micromolar concentrations of ara-A sensitized only the two most radioresistant lines, SCC-12B.2 and JSQ-3. Five hundred micromolar concentrations of ara-A sensitized the more sensitive cell lines, SQ-20B and SQ-9G, but failed to have any effect on the radiation response of the two most sensitive cell lines, SQ-38 and SCC-61. Concentrations of ara-A as low as 10 {mu}M were equally efficient in inhibiting DNA synthesis in all six cell lines. These results suggest that the target for the radiosensitizing effect of ara-A is probably related to the factor controlling the inherent radiosensitivity of human tumor cells. Therefore, ara-A might be useful in overcoming radiation resistance in vivo.

  2. Analysing and Comparing Encodability Criteria

    Directory of Open Access Journals (Sweden)

    Kirstin Peters

    2015-08-01

    Full Text Available Encodings or the proof of their absence are the main way to compare process calculi. To analyse the quality of encodings and to rule out trivial or meaningless encodings, they are augmented with quality criteria. There exists a bunch of different criteria and different variants of criteria in order to reason in different settings. This leads to incomparable results. Moreover it is not always clear whether the criteria used to obtain a result in a particular setting do indeed fit to this setting. We show how to formally reason about and compare encodability criteria by mapping them on requirements on a relation between source and target terms that is induced by the encoding function. In particular we analyse the common criteria full abstraction, operational correspondence, divergence reflection, success sensitiveness, and respect of barbs; e.g. we analyse the exact nature of the simulation relation (coupled simulation versus bisimulation that is induced by different variants of operational correspondence. This way we reduce the problem of analysing or comparing encodability criteria to the better understood problem of comparing relations on processes.

  3. Comparisons of sensitivity on X-ray and diethyl sulfate in M1 seedling stage of welsh onion

    International Nuclear Information System (INIS)

    Lee, B.K.; Eun, J.S.; Park, H.B.

    1977-01-01

    In order to select useful mutants, dormant seeds of a Welsh onion variety ''Baekeunju'' were treated with different levels of X-ray and diethyl sulfate (DES). For this study, the sensitivities on germination, emergence, seedling height, and chromosome aberrations in root tip cells were investigated in M 1 seedling stage. The results obtained were summarized as follow: The germination rate was not influenced by X-ray irradiation but in plots of DES treatment it was significantly decreased according to increasing of the DES concentration. A significant reduction to emergence rate and seedling height measured on 30th day after sowing was in direct proportion to increasing of the X-ray dose and the DES concentration. Fifty per cent growth reduction dose and concentration was determined to about 33kR for X-ray, and about 0.12% for EES. The chromosome aberration, such as chromosome fragment, chromosome bridge and chromosomering, was shown much frequently in plants treated with high dose or concentration of the both mutagens. However, the DES made less aberration of chromosome than the X-ray in average of all the treated concentrations. A trend was also observed that the X-ray irradiation made more chromosome fragments than chromosome bridges and the DES treatment more chromosome bridges than chromosome fragments. (author)

  4. Enhanced sensitivity to neoplastic transformation by 137Cs γ-rays of cells in the G2-/M-phase age interval

    International Nuclear Information System (INIS)

    Cao, J.; Wells, R.L.; Elkind, M.M.

    1992-01-01

    C3H mouse 10T1/2 cells, exposed to low doses of fission-spectrum neutrons, have an enhanced frequency of neoplastic transformation if protracted exposures are used (Hill et al. 1982, 1984a, 1985). To explain this anormaly, a biophysical model was proposed (Elkind 1991 a,b). The unique shape and radiobiological properties of cells in and around mitosis, led to the proposal that the sensitive window is mitosis and possible cells just preceding or just following M phase (Elkind 1991a,b). This study was undertaken using 137 Cs γ-rays. The authors found that late G 2- to M-phase 10T1/2 cells have a maximal sensitivity to neoplastic transformation as well as to killing by 137 Cs γ-rays. (author)

  5. Numerical modeling of the sensitivity of x-ray driven implosions to low-mode flux asymmetries.

    Science.gov (United States)

    Scott, R H H; Clark, D S; Bradley, D K; Callahan, D A; Edwards, M J; Haan, S W; Jones, O S; Spears, B K; Marinak, M M; Town, R P J; Norreys, P A; Suter, L J

    2013-02-15

    The sensitivity of inertial confinement fusion implosions, of the type performed on the National Ignition Facility (NIF) [1], to low-mode flux asymmetries is investigated numerically. It is shown that large-amplitude, low-order mode shapes (Legendre polynomial P(4), resulting from low-order flux asymmetries, cause spatial variations in capsule and fuel momentum that prevent the deuterium and tritium (DT) "ice" layer from being decelerated uniformly by the hot spot pressure. This reduces the transfer of implosion kinetic energy to internal energy of the central hot spot, thus reducing the neutron yield. Furthermore, synthetic gated x-ray images of the hot spot self-emission indicate that P(4) shapes may be unquantifiable for DT layered capsules. Instead the positive P(4) asymmetry "aliases" itself as an oblate P(2) in the x-ray images. Correction of this apparent P(2) distortion can further distort the implosion while creating a round x-ray image. Long wavelength asymmetries may be playing a significant role in the observed yield reduction of NIF DT implosions relative to detailed postshot two-dimensional simulations.

  6. Unique sensitivity of the rabbit eye to X-ray-induced ocular inflammation

    Energy Technology Data Exchange (ETDEWEB)

    Bito, L Z; Klein, E M [Columbia Univ., New York (USA). Coll. of Physicians and Surgeons

    1981-10-01

    The effects of X-irradiation of the eye on ocular parameters known to be altered during the inflammatory process were studied on albino and pigmented rabbits, guinea pigs, owl monkeys, cats ducks and pigeons. Within 1.5-3.0 hr after exposure to 10 Gy (1000 rads), all irradiated eyes of either albino or pigmented rabbits showed a significant increase in intraocular pressure, iridial hyperemia, and development of flare and presence of cells in the anterior chamber. Four hours after exposure, the concentration of soluble proteins in the aqueous humor was increased, while that of ascorbic acid was decreased. In contrast, eyes of owl monkeys, cats guinea pigs, ducks and pigeons, exposed to the same or, in some cases, up to eight times higher doses of X-rays, showed no hypertension or development of other parameters of intraocular inflammation. These and previous findings suggest that rabbits, or possibly Lagomorphs in general, are unique among vertebrates in their sensitivity to the early intraocular inflammatory effects of X-rays. In addition, these results seriously question the use of this species as the primary, and frequently sole model for the study of ocular inflammation, its mediation and therapeutics.

  7. Sensitivity of UF-R, UF-VCh, UF-VR films used for soft x-ray (lambda=2+10A) detection

    International Nuclear Information System (INIS)

    Aglitskij, E.V.; Bojko, V.A.; Kalinkina, T.A.

    1975-01-01

    The sensitometric characteristics of the following types of photographic film were measured in the range of wavelengths 2-10A: UF-R, UF-VCh, and UF-VR. It was demonstrated that UF-VR photographic film is four times as sensitive as UF-R film and 1.6 times as sensitive as UF-VCh film; it is also most suitable film for x-ray spectroscopy of multiply charged ions and for diagnosing high-temperature laser plasma

  8. 5-chlorodeoxycytidine sensitizes cells to x-ray and is incorporated as 5-chlorodeoxyuridine in tumor DNA

    International Nuclear Information System (INIS)

    Perez, L.M.; Greer, S.

    1985-01-01

    5-Chlorodeoxycytidine (CldC) coadministered with tetrahydrouridine (H/sub 4/U), an inhibitor of its deamination, sensitizes HEp-2 cells to X-ray and is incorporated in DNA as 5-chlorodeoxyuridine (CldU). CldC possesses a reasonable Km value (56 μM) with respect to human deoxycytidine kinase (dCK) in contrast to the low affinities of BrdC and IdC (400 and 1000μM, respectively; the Km value for dC = 2μM). Preincubation with N-phosphonacetyl-L-aspartate (PALA) and 5-fluorodeoxyuridine (FdU), inhibitors of pyrimidine biosynthesis, enhances sensitization. X-ray survival curves of HEp-2 cells treated with PALA and FdU (or FdC + H/sub 4/U) and CldC + H/sub 4/U are characterized by dose enhancement ratios of 2.5 or greater. Substantial sensitization by CldC + H/sub 4/U also occurs with Sarcoma-180 and RIF-1 cells in culture . CldC + H/sub 4/U should result in circumvention of catabolism and selective toxicity to tumors via inhibition of nucleoside reductase by CldUTP as well as selective incorporation of CldU in tumors possessing high levels of dCMP deaminase and dCK, enzymes that are markedly elevated in many human tumors. CldU, derived from CldC, is incorporated to a greater extent in the DNA of a solid tumor (S-180) than in normal tissue of the mouse. This may result in selective tumor radiosensitization

  9. Airborne gamma-ray spectrometer and magnetometer survey, Sagavanirktok Quadrangle, Alaska. Volume I. Final report

    International Nuclear Information System (INIS)

    1981-03-01

    The results obtained from an airborne high sensitivity gamma-ray spectrometer and magnetometer survey over the Sagavanirktok map area of Alaska are presented. Based on the criteria outlined in the general section on interpretation, a total of eight uranium anomalies have been outlined on the interpretation map. However, all of these zones are only weakly to moderately anomalous. None are thought to be indicative of local enrichment of uranium to economically significant levels. No follow-up work is recommended

  10. The CTA Sensitivity to Lorentz-Violating Effects on the Gamma-Ray Horizon

    CERN Document Server

    Fairbairn, Malcolm; Ellis, John; Hinton, Jim; White, Richard

    2014-01-01

    The arrival of TeV-energy photons from distant galaxies is expected to be affected by their QED interaction with intergalactic radiation fields through electron-positron pair production. In theories where high-energy photons violate Lorentz symmetry, the kinematics of the process $\\gamma + \\gamma\\rightarrow e^+ + e^-$ is altered and the cross-section suppressed. Consequently, one would expect more of the highest-energy photons to arrive if QED is modified by Lorentz violation than if it is not. We estimate the sensitivity of Cherenkov Telescope Array (CTA) to changes in the $\\gamma$-ray horizon of the Universe due to Lorentz violation, and find that it should be competitive with other leading constraints.

  11. Performance of classification criteria for gout in early and established disease

    DEFF Research Database (Denmark)

    Taylor, William J; Fransen, Jaap; Dalbeth, Nicola

    2016-01-01

    OBJECTIVES: To compare the sensitivity and specificity of different classification criteria for gout in early and established disease. METHODS: This was a cross-sectional study of consecutive rheumatology clinic patients with joint swelling in which gout was defined by presence or absence...... of monosodium urate crystals as observed by a certified examiner at presentation. Early disease was defined as patient-reported onset of symptoms of 2 years or less. RESULTS: Data from 983 patients were collected and gout was present in 509 (52%). Early disease was present in 144 gout cases and 228 non.......3%/84.4% and 86.4%/63.6%. Criteria not requiring synovial fluid analysis had sensitivity and specificity of less than 80% in early and established disease. CONCLUSIONS: Existing classification criteria for gout have sensitivity of over 80% in early and established disease but currently available criteria that do...

  12. Sensitization of Micrococcus radiophilus to gamma-rays by postirradiation incubation with chloramphenicol or at nonpermissive temperature

    Energy Technology Data Exchange (ETDEWEB)

    Kitayama, S; Harsojo,; Matsuyama, A [Institute of Physical and Chemical Research, Wako, Saitama (Japan)

    1980-12-01

    M. radiophilus was sensitized to gamma-rays by postirradiation incubation at 42/sup 0/C or at 30/sup 0/C in the presence of chloramphenicol. Radiation induced strand scissions and alkali labile bonds in DNA were repaired by post-irradiation incubation under normal conditions. However, these lesions were repaired only partially during the incubation at 42/sup 0/C or in the presence of chloramphenicol.

  13. Accuracy of Carotid Duplex Criteria in Diagnosis of Significant Carotid Stenosis in Asian Patients.

    Science.gov (United States)

    Dharmasaroja, Pornpatr A; Uransilp, Nattaphol; Watcharakorn, Arvemas; Piyabhan, Pritsana

    2018-03-01

    Extracranial carotid stenosis can be diagnosed by velocity criteria of carotid duplex. Whether they are accurately applied to define severity of internal carotid artery (ICA) stenosis in Asian patients needs to be proved. The purpose of this study was to evaluate the accuracy of 2 carotid duplex velocity criteria in defining significant carotid stenosis. Carotid duplex studies and magnetic resonance angiography were reviewed. Criteria 1 was recommended by the Society of Radiologists in Ultrasound; moderate stenosis (50%-69%): peak systolic velocity (PSV) 125-230 cm/s, diastolic velocity (DV) 40-100 cm/s; severe stenosis (>70%): PSV greater than 230 cm/s, DV greater than 100 cm/s. Criteria 2 used PSV greater than 140 cm/s, DV less than 110 cm/s to define moderate stenosis (50%-75%) and PSV greater than 140 cm/s, DV greater than 110 cm/s for severe stenosis (76%-95%). A total of 854 ICA segments were reviewed. There was moderate stenosis in 72 ICAs, severe stenosis in 50 ICAs, and occlusion in 78 ICAs. Criteria 2 had slightly lower sensitivity, whereas higher specificity and accuracy than criteria 1 were observed in detecting moderate stenosis (criteria 1: sensitivity 95%, specificity 83%, accuracy 84%; criteria 2: sensitivity 92%, specificity 92%, and accuracy 92%). However, in detection of severe ICA stenosis, no significant difference in sensitivity, specificity, and accuracy was found (criteria 1: sensitivity 82%, specificity 99.57%, accuracy 98%; criteria 2: sensitivity 86%, specificity 99.68%, and accuracy 99%). In the subgroup of moderate stenosis, the criteria using ICA PSV greater than 140 cm/s had higher specificity and accuracy than the criteria using ICA PSV 125-230 cm/s. However, there was no significant difference in detection of severe stenosis or occlusion of ICA. Copyright © 2018 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  14. Genetic analysis of gamma-ray mutagenesis in yeast. I. Reversion in radiation-sensitive strains

    International Nuclear Information System (INIS)

    McKee, R.H.; Lawrence, C.W.

    1979-01-01

    The frequency of revertants induced by 60 Co γ rays of the ochre allele, cyc1-9, has been measured in radiation-sensitive strains carrying one of 19 nonallelic mutations and in wild-type strains. The results indicate that ionizing radiation mutagenesis depends on the activity of the RAD6 group of genes and that the gene functions employed are very similar, but probably not identical, to those that mediate uv mutagenesis. Repair activities dependent on the functions of the RAD50 through RAD57 loci, the major pathway for the repair of damage caused by ionizing radiation, do not appear to play any part in mutagenesis. A comparison between the γ-ray data and those obtained previously with uv and chemical mutagens suggests that the RAD6 mutagenic pathway is in fact composed of a set of processes, some of which are concerned with error-prone, and some with error-free, recovery activities

  15. Simbol-X: Imaging The Hard X-ray Sky with Unprecedented Spatial Resolution and Sensitivity

    Science.gov (United States)

    Tagliaferri, Gianpiero; Simbol-X Joint Scientific Mission Group

    2009-01-01

    Simbol-X is a hard X-ray mission, with imaging capability in the 0.5-80 keV range. It is based on a collaboration between the French and Italian space agencies with participation of German laboratories. The launch is foreseen in late 2014. It relies on a formation flight concept, with two satellites carrying one the mirror module and the other one the focal plane detectors. The mirrors will have a 20 m focal length, while the two focal plane detectors will be put one on top of the other one. This combination will provide over two orders of magnitude improvement in angular resolution and sensitivity in the hard X-ray range with respect to non-focusing techniques. The Simbol-X revolutionary instrumental capabilities will allow us to elucidate outstanding questions in high energy astrophysics such as those related to black-holes accretion physics and census, and to particle acceleration mechanisms. We will give an overall description of the mission characteristics, performances and scientific objectives.

  16. Two mutations which confer temperature-sensitive radiation sensitivity in the yeast Saccharomyces cerevisiae

    International Nuclear Information System (INIS)

    Ho, K.S.Y.; Mortimer, R.K.

    1975-01-01

    X-ray survival curves for two mutations, rad54 and rad55, in the yeast Saccharomyces cerevisiae are presented. These mutations confer temperature sensitive X-ray sensitivity; that is, rad54 and rad55 strains display a wild type X-ray survival response at permissive temperatures and a radiosensitive X-ray survival response at restrictive temperatures. The survival response of cells which were shifted from a permissive to a restrictive temperature or vice versa at various post-irradiation times indicates that repair and fixation of X-ray induced lesions is largely complete three hours after X-irradiation. Experiments to determine the utilization sequence of the rad54 and rad55 gene products in the repair of X-ray induced damage suggest that the two products are required in an interdependent manner

  17. Very high-energy gamma rays from gamma-ray bursts.

    Science.gov (United States)

    Chadwick, Paula M

    2007-05-15

    Very high-energy (VHE) gamma-ray astronomy has undergone a transformation in the last few years, with telescopes of unprecedented sensitivity having greatly expanded the source catalogue. Such progress makes the detection of a gamma-ray burst at the highest energies much more likely than previously. This paper describes the facilities currently operating and their chances for detecting gamma-ray bursts, and reviews predictions for VHE gamma-ray emission from gamma-ray bursts. Results to date are summarized.

  18. Evaluation of the x-ray response of a position-sensitive microstrip detector with an integrated readout chip

    International Nuclear Information System (INIS)

    Rossington, C.; Jaklevic, J.; Haber, C.; Spieler, H.; Reid, J.

    1990-08-01

    The performance of an SVX silicon microstrip detector and its compatible integrated readout chip have been evaluated in response to Rh Kα x-rays (average energy 20.5 keV). The energy and spatial discrimination capabilities, efficient data management and fast readout rates make it an attractive alternative to the CCD and PDA detectors now being offered for x-ray position sensitive diffraction and EXAFS work. The SVX system was designed for high energy physics applications and thus further development of the existing system is required to optimize it for use in practical x-ray experiments. For optimum energy resolution the system noise must be decreased to its previously demonstrated low levels of 2 keV FWHM at 60 keV or less, and the data handling rate of the computer must be increased. New readout chips are now available that offer the potential of better performance. 15 refs., 7 figs

  19. Cytochrome C effect on gamma-ray efficiency on barley seeds at different metabolic states

    International Nuclear Information System (INIS)

    Yankulov, M.

    1981-01-01

    Radiobiological studies of the effect of gamma-rays on the barley seeds were performed. It was shown that the different metabolic states of the seeds do not modify the effect of the independent treatment with cytochrome C, while the action of the gamma-rays is markedly modified. With the increase in the preliminary seed soaking time in H 2 O, the total lethality in the case of irradiated treatments rises from 54.10% to 91.00% and that of sterility to 13.13 and 57.44% for 12 and 72 hrs, respectively. The preliminary and post-irradiation treatment of seeds with cytochrome C markedly reduces the effect of gamma-rays, calculated by the criteria of general lethality and sterility, the trend towards an increase in the sensitivity with the increase in the extention of the preliminary soaking time of seeds in water being preserved. Preliminary soaking in the seeds in water also modifies the mutagenic effect of gamma-rays to a considerable extent. (author)

  20. Adequacy Criteria of Models of the Cargo Inspection System with Material Discrimination Option

    International Nuclear Information System (INIS)

    Osipov, S; Chakhlov, S; Osipov, O; Shtein, A; Van, J

    2016-01-01

    Generalized adequacy criteria for mathematical models in order to discriminate materials in X-ray inspection systems by the dual-energy method were developed. Two main approaches of the examination systems to produce the adequacy criteria by the final and the intermediate parameters of the dual-energy method were analyzed. The criteria were specified in respect to the discrimination by the effective atomic number and by the method of level functions. Experimental and theoretical estimates of the discrimination parameters of the test object constituents scanned by fan beams of X-ray radiation with the maximal energies of 4.5 and 9 MeV are given. (paper)

  1. The 2HWC HAWC Observatory Gamma-Ray Catalog

    Energy Technology Data Exchange (ETDEWEB)

    Abeysekara, A. U.; Barber, A. S. [Department of Physics and Astronomy, University of Utah, Salt Lake City, UT (United States); Albert, A. [Physics Division, Los Alamos National Laboratory, Los Alamos, NM (United States); Alfaro, R.; Becerril, A.; Belmont-Moreno, E. [Instituto de Física, Universidad Nacional Autónoma de México, Mexico City (Mexico); Alvarez, C.; Arceo, R.; Caballero-Mora, K. S. [Universidad Autónoma de Chiapas, Tuxtla Gutiérrez, Chiapas (Mexico); Álvarez, J. D.; Arteaga-Velázquez, J. C. [Universidad Michoacana de San Nicolás de Hidalgo, Morelia (Mexico); Solares, H. A. Ayala; Brisbois, C. [Department of Physics, Michigan Technological University, Houghton, MI (United States); Baughman, B.; Berley, D. [Department of Physics, University of Maryland, College Park, MD (United States); Bautista-Elivar, N. [Universidad Politecnica de Pachuca, Pachuca, Hidalgo (Mexico); Gonzalez, J. Becerra [NASA Goddard Space Flight Center, Greenbelt, MD (United States); BenZvi, S. Y. [Department of Physics and Astronomy, University of Rochester, Rochester, NY (United States); Bernal, A. [Instituto de Astronomía, Universidad Nacional Autónoma de México, Mexico City (Mexico); Braun, J., E-mail: riviere@umdgrb.umd.edu [Department of Physics, University of Wisconsin-Madison, Madison, WI (United States); and others

    2017-07-01

    We present the first catalog of TeV gamma-ray sources realized with data from the newly completed High Altitude Water Cherenkov Observatory (HAWC). It is the most sensitive wide field-of-view TeV telescope currently in operation, with a one-year survey sensitivity of ∼5%–10% of the flux of the Crab Nebula. With an instantaneous field of view >1.5 sr and >90% duty cycle, it continuously surveys and monitors the sky for gamma-ray energies between hundreds of GeV and tens of TeV. HAWC is located in Mexico, at a latitude of 19° N, and was completed in 2015 March. Here, we present the 2HWC catalog, which is the result of the first source search performed with the complete HAWC detector. Realized with 507 days of data, it represents the most sensitive TeV survey to date for such a large fraction of the sky. A total of 39 sources were detected, with an expected number of false detections of 0.5 due to background fluctuation. Out of these sources, 19 are new sources that are not associated with previously known TeV sources (association criteria: <0.°5 away). The source list, including the position measurement, spectrum measurement, and uncertainties, is reported, then each source is briefly discussed. Of the 2HWC associated sources, 10 are reported in TeVCat as PWN or SNR: 2 as blazars and the remaining eight as unidentified.

  2. Prognostic x-ray criteria of cute lung abscess course

    International Nuclear Information System (INIS)

    Churilyin, R.Yu.; Kramnij, Yi.O.

    2008-01-01

    Thorough study of the findings obtained during x-ray investigation and tomography of the lungs allows the prognosis of the disease course and working out an optimal treatment protocol to prevent possible complications

  3. A proposal of criteria for the classification of systemic sclerosis.

    Science.gov (United States)

    Nadashkevich, Oleg; Davis, Paul; Fritzler, Marvin J

    2004-11-01

    Sensitive and specific criteria for the classification of systemic sclerosis are required by clinicians and investigators to achieve higher quality clinical studies and approaches to therapy. A clinical study of systemic sclerosis patients in Europe and Canada led to a set of criteria that achieve high sensitivity and specificity. Both clinical and laboratory investigations of patients with systemic sclerosis, related conditions and diseases with clinical features that can be mistaken as part of the systemic sclerosis spectrum were undertaken. Laboratory investigations included the detection of autoantibodies to centromere proteins, Scl-70 (topoisomerase I), and fibrillarin (U3-RNP). Based on the investigation of 269 systemic sclerosis patients and 720 patients presenting with related and confounding conditions, the following set of criteria for the classification of systemic sclerosis was proposed: 1) autoantibodies to: centromere proteins, Scl-70 (topo I), fibrillarin; 2) bibasilar pulmonary fibrosis; 3) contractures of the digital joints or prayer sign; 4) dermal thickening proximal to the wrists; 5) calcinosis cutis; 6) Raynaud's phenomenon; 7) esophageal distal hypomotility or reflux-esophagitis; 8) sclerodactyly or non-pitting digital edema; 9) teleangiectasias. The classification of definite SSc requires at least three of the above criteria. Criteria for the classification of systemic sclerosis have been proposed. Preliminary testing has defined the sensitivity and specificity of these criteria as high as 99% and 100%, respectively. Testing and validation of the proposed criteria by other clinical centers is required.

  4. Airborne gamma-ray spectrometer and magnetometer survey, Meade River Quadrangle, Alaska. Final report

    International Nuclear Information System (INIS)

    1981-02-01

    The results obtained from an airborne high sensitivity gamma-ray spectrometer and magnetometer survey over the Meade River map area of Alaska are presented. Based on the criteria outlined in the general section on interpretation, a total of eight uranium anomalies have been outlined on the interpretation map. Most of these are only weakly to moderately anomalous. Zones 3 and 7 are relatively better than the others though none of the anomalies are thought to be of any economic significance. No follow-up work is recommended

  5. Electronic noise in charge sensitive preamplifiers for X-ray spectroscopy and the benefits of a SiC input JFET

    Energy Technology Data Exchange (ETDEWEB)

    Lioliou, G., E-mail: G.Lioliou@sussex.ac.uk; Barnett, A.M.

    2015-11-21

    A comprehensive summary and analysis of the electronic noise affecting the resolution of X-ray, γ-ray and particle counting spectroscopic systems which employ semiconductor detectors and charge sensitive preamplifiers is presented. The noise arising from the input transistor of the preamplifier and its contribution to the total noise is examined. A model for computing the noise arising from the front-end transistor is also presented and theoretical calculations comparing the noise contribution of transistors made of different materials are discussed, emphasizing the advantages of wide bandgap transistor technology.

  6. Relationships between hole type penetrameter sensitivities and wire type penetrameter sensitivities

    International Nuclear Information System (INIS)

    Iwahashi, Y.; Ebata, M.; Ooka, K.; Hirayama, K.; Senda, T.

    1985-01-01

    Radiographic investigations were conducted using the two types of penetrameters (hole and wire types) to obtain the relationships between hole type penetrameter sensitivities and wire type penetrameter sensitivities. Furthermore, the effects of radiation sources and kinds of X-ray films on the relationships were investigated. As a result, the quantitative relationship were defined. It was also clarified that the kinds of X-ray films and radiation sources have a relatively little effect on the relationship

  7. Phase-contrast X-ray CT

    Energy Technology Data Exchange (ETDEWEB)

    Momose, Atsushi [Hitachi Ltd., Saitama (Japan). Advanced Research Laboratory; Takeda, Tohoru; Itai, Yuji

    1995-12-01

    Phase-contrast X-ray computed tomography (CT) enabling the observation of biological soft tissues without contrast enhancement has been developed. The X-ray phase shift caused by an object is measured and input to a standard CT reconstruction algorithm. A thousand times increase in the image sensitivity to soft tissues is achieved compared with the conventional CT using absorption contrast. This is because the X-ray phase shift cross section of light elements is about a thousand times larger than the absorption cross section. The phase shift is detected using an X-ray interferometer and computer analyses of interference patterns. Experiments were performed using a synchrotron X-ray source. Excellent image sensitivity is demonstrated in the observation of cancerous rabbit liver. The CT images distinguish cancer lesion from normal liver tissue and, moreover, visualize the pathological condition in the lesion. Although the X-ray energy employed and the present observation area size are not suitable for medical applications as they are, phase-contrast X-ray CT is promising for investigating the internal structure of soft tissue which is almost transparent for X-rays. The high sensitivity also provides the advantage of reducing X-ray doses. (author).

  8. Selective chest imaging for blunt trauma patients: The national emergency X-ray utilization studies (NEXUS-chest algorithm).

    Science.gov (United States)

    Rodriguez, Robert M; Hendey, Gregory W; Mower, William R

    2017-01-01

    Chest imaging plays a prominent role in blunt trauma patient evaluation, but indiscriminate imaging is expensive, may delay care, and unnecessarily exposes patients to potentially harmful ionizing radiation. To improve diagnostic chest imaging utilization, we conducted 3 prospective multicenter studies over 12years to derive and validate decision instruments (DIs) to guide the use of chest x-ray (CXR) and chest computed tomography (CT). The first DI, NEXUS Chest x-ray, consists of seven criteria (Age >60years; rapid deceleration mechanism; chest pain; intoxication; altered mental status; distracting painful injury; and chest wall tenderness) and exhibits a sensitivity of 99.0% (95% confidence interval [CI] 98.2-99.4%) and a specificity of 13.3% (95% CI, 12.6%-14.0%) for detecting clinically significant injuries. We developed two NEXUS Chest CT DIs, which are both highly reliable in detecting clinically major injuries (sensitivity of 99.2%; 95% CI 95.4-100%). Designed primarily to focus on detecting major injuries, the NEXUS Chest CT-Major DI consists of six criteria (abnormal CXR; distracting injury; chest wall tenderness; sternal tenderness; thoracic spine tenderness; and scapular tenderness) and exhibits higher specificity (37.9%; 95% CI 35.8-40.1%). Designed to reliability detect both major and minor injuries (sensitivity 95.4%; 95% CI 93.6-96.9%) with resulting lower specificity (25.5%; 95% CI 23.5-27.5%), the NEXUS CT-All rule consists of seven elements (the six NEXUS CT-Major criteria plus rapid deceleration mechanism). The purpose of this review is to synthesize the three DIs into a novel, cohesive summary algorithm with practical implementation recommendations to guide selective chest imaging in adult blunt trauma patients. Copyright © 2016 Elsevier Inc. All rights reserved.

  9. Age estimation of burbot using pectoral fin rays, brachiostegal rays, and otoliths

    Science.gov (United States)

    Klein, Zachary B.; Terrazas, Marc M.; Quist, Michael C.

    2014-01-01

    Throughout much of its native distribution, burbot (Lota lota) is a species of conservation concern. Understanding dynamic rate functions is critical for the effective management of sensitive burbot populations, which necessitates accurate and precise age estimates. Managing sensitive burbot populations requires an accurate and precise non-lethal alternative. In an effort to identify a non-lethal ageing structure, we compared the precision of age estimates obtained from otoliths, pectoral fin rays, dorsal fin rays and branchiostegal rays from 208 burbot collected from the Green River drainage, Wyoming. Additionally, we compared the accuracy of age estimates from pectoral fin rays, dorsal fin rays and branchiostegal rays to those of otoliths. Dorsal fin rays were immediately deemed a poor ageing structure and removed from further analysis. Age-bias plots of consensus ages derived from branchiostegal rays and pectoral fin rays were appreciably different from those obtained from otoliths. Exact agreement between readers and reader confidence was highest for otoliths and lowest for branchiostegal rays. Age-bias plots indicated that age estimates obtained from branchiostegal rays and pectoral fin rays were substantially different from age estimates obtained from otoliths. Our results indicate that otoliths provide the most precise age estimates for burbot.

  10. The noise analysis and optimum filtering techniques for a two-dimensional position sensitive orthogonal strip gamma ray detector employing resistive charge division

    International Nuclear Information System (INIS)

    Gerber, M.S.; Muller, D.W.

    1976-01-01

    The analysis of an orthogonal strip, two-dimensional position sensitive high purity germanium gamma ray detector is discussed. Position sensitivity is obtained by connecting each electrode strip on the detector to a resistor network. Charge, entering the network, divides in relation to the resistance between its entry point and the virtual earth points of the charge sensitive preamplifiers located at the end of each resistor network. The difference of the voltage pulses at the output of each preamplifier is proportional to the position at which the charge entered the resistor network and the sum of the pulse is proportional to the energy of the detected gamma ray. The analysis and spatial noise resolution is presented for this type of position sensitive detector. The results of the analysis show that the position resolution is proportional to the square root of the filter amplifier's output pulse time constant and that for energy measurement the resolution is maximized at the filter amplifier's noise corner time constant. The design of the electronic noise filtering system for the prototype gamma ray camera was based on the mathematical energy and spatial resolution equations. For the spatial channel a Gaussian trapezoidal filtering system was developed. Gaussian filtering was used for the energy channel. The detector noise model was verified by taking rms noise measurements of the filtered energy and spatial pulses from resistive readout charge dividing detectors. These measurements were within 10% of theory. (Auth.)

  11. Modifications of γ-ray sensitivity of bacterial membranes by pre-exposure to light

    International Nuclear Information System (INIS)

    Misiti-Dorello, P.; Cancelliere, G.; De Martino, G.; Quintilini, M.

    1976-01-01

    The exposure of E. coli B/r cells to ultraviolet or to visible light prior to irradiation with γ-rays modifies the sensitivity of the cell membrane to radiation damage responsible for the intracellular K + content. Exposure of bacterial cells to sublethal doses of UV radiation increases their sensitivity to γ-induced membrane damage, while exposure to visible light has the opposite effect. In combined exposures, the visible light, either given before or after the UV always produces a strong photoprotective effect. In either case, the photosensitizing effect of UV is completely suppressed. The photoprotection decays with time if cell suspensions are left in the dark before γ-irradiation. At O 0 C, the half-life of the photoprotective effect is 25 min at pH 7 and 100 min at pH 7.5. The decay is due to the presence of oxygen. The light band responsible for the induction of photoprotection has been estimated to lie in the wavelenght region between 540 and 580 nm. (orig./MG) [de

  12. Optimization of polarimetry sensitivity for X-ray CCD

    CERN Document Server

    Hayashida, K; Tsunemi, H; Hashimoto, Y; Ohtani, M

    1999-01-01

    X-ray polarimetry with CCD has been performed using a polarized X-ray beam from an electron impact X-ray source. The standard data reduction method employing double-pixel events yields the modulation factor M of 0.14 at 27 keV and 0.24 at 43 keV for the 12 mu m pixel size CCD chip. We develop a new data reduction method, in which multi-pixel events are employed, and which approximates the charge spread as an oval shape. We optimize the reduction parameters, so that we improve the P sub m sub i sub n (minimum detectable polarization degree) by factor of three from the value obtained through the usual double-pixel event method.

  13. A sensitization effect of hematoporphyrin oligomer (HpO) and caffeine for X-ray radiation of skin cancer

    International Nuclear Information System (INIS)

    Ishiguro, Kazumori; Ueda, Keiichi; Miyoshi, Norio; Nakanishi, Kazuo; Fukuda, Masaru

    1990-01-01

    Human malignant melanoma cells (G-361) were irradiated with X-ray for different irradiation times. The amount of DNA damage was much increased by the treatment of the cells with hematoporphyrin oligomer (HpO) before X-ray irradiation. Furthermore, it was found that the caffeine inhibited effectively the repair of the damaged DNA. Furthermore, HpO was administered before X-ray irradiation of transplantable skin tumor in C3H mice and/or caffeine was to be given the mouse after X-ray irradiation. The growth of the irradiated tumor combined with HpO and/or caffeine was more inhibited, and the necrotic area was more expanded than that of the tumor irradiated with X-ray only. Labeling Index utilizing bromodeoxyuridine (BrdU) in the viable area of the treated tumor decreased when HpO and/or caffeine were administered. The amount of DNA damage more increased in the irradiated tumor cells given HpO than the only irradiated cells. And, the repair of the damaged DNA was more delayed in the irradiated tumor cells combined with HpO and caffeine than those with other treatments. In conclusion, it was considered that HpO might be a radioactive sensitizer and caffeine enhanced the inhibition of the repair of DNA damaged. We hope that the treatment of X-ray radiation combined with HpO and caffeine is useful for clinical treatment of human malignant tumor. (author) 54 refs

  14. A sensitization effect of hematoporphyrin oligomer (HpO) and caffeine for X-ray radiation of skin cancer

    Energy Technology Data Exchange (ETDEWEB)

    Ishiguro, Kazumori; Ueda, Keiichi; Miyoshi, Norio; Nakanishi, Kazuo; Fukuda, Masaru (Fukui Medical School, Matsuoka (Japan))

    1990-05-01

    Human malignant melanoma cells (G-361) were irradiated with X-ray for different irradiation times. The amount of DNA damage was much increased by the treatment of the cells with hematoporphyrin oligomer (HpO) before X-ray irradiation. Furthermore, it was found that the caffeine inhibited effectively the repair of the damaged DNA. Furthermore, HpO was administered before X-ray irradiation of transplantable skin tumor in C3H mice and/or caffeine was to be given the mouse after X-ray irradiation. The growth of the irradiated tumor combined with HpO and/or caffeine was more inhibited, and the necrotic area was more expanded than that of the tumor irradiated with X-ray only. Labeling Index utilizing bromodeoxyuridine (BrdU) in the viable area of the treated tumor decreased when HpO and/or caffeine were administered. The amount of DNA damage more increased in the irradiated tumor cells given HpO than the only irradiated cells. And, the repair of the damaged DNA was more delayed in the irradiated tumor cells combined with HpO and caffeine than those with other treatments. In conclusion, it was considered that HpO might be a radioactive sensitizer and caffeine enhanced the inhibition of the repair of DNA damaged. We hope that the treatment of X-ray radiation combined with HpO and caffeine is useful for clinical treatment of human malignant tumor. (author) 54 refs.

  15. X-ray criteria of the differential diagnosis of hereditary tubulopathies in children

    International Nuclear Information System (INIS)

    Bosin, V.Yu.; Kondrina, V.V.; Mulyk, T.E.; Verbitskaya, A.I.

    1995-01-01

    In search for x-ray signs of skeletal involvement specific for each type of hereditary tubulopathies Vitamin D-resistant rickets, Renal tubular acidosis, Toni-Debre-Fanconi disease, the authors analyze the results of clinical and X-ray examinations of 144 children aged 2 to 16. Study demonstrated the possibility and high reliability of X-ray differential diagnosis of various forms of hereditary tubulopathies in children. 5 refs., 8 figs., 2 tabs

  16. The unique sensitivity of the rabbit eye to X-ray-induced ocular inflammation

    International Nuclear Information System (INIS)

    Bito, L.Z.; Klein, E.M.

    1981-01-01

    The effects of X-irradiation of the eye on ocular parameters known to be altered during the inflammatory process were studied on albino and pigmented rabbits, guinea pigs, owl monkeys, cats ducks and pigeons. Within 1.5-3.0 hr after exposure to 10 Gy (1000 rads), all irradiated eyes of either albino or pigmented rabbits showed a significant increase in intraocular pressure, iridial hyperemia, and development of flare and presence of cells in the anterior chamber. Four hours after exposure, the concentration of soluble proteins in the aqueous humor was increased, while that of ascorbic acid was decreased. In contrast, eyes of owl monkeys, cats guinea pigs, ducks and pigeons, exposed to the same or, in some cases, up to eight times higher doses of X-rays, showed no hypertension or development of other parameters of intraocular inflammation. These and previous findings suggest that rabbits, or possibly Lagomorphs in general, are unique among vertebrates in their sensitivity to the early intraocular inflammatory effects of X-rays. In addition, these results seriously question the use of this species as the primary, and frequently sole model for the study of ocular inflammation, its mediation and therapeutics. (author)

  17. The Assessment of SpondyloArthritis International Society classification criteria for peripheral spondyloarthritis and for spondyloarthritis in general

    DEFF Research Database (Denmark)

    Rudwaleit, M; van der Heijde, D; Landewé, R

    2011-01-01

    as reference standard. RESULTS: In all, 24 ASAS centres included 266 patients, with a final diagnosis of SpA being made in 66.2%. After adjustments a final set of criteria showed the best balance between sensitivity (77.8%) and specificity (82.9%): arthritis and/or enthesitis and/or dactylitis plus (A) one...... criteria for peripheral SpA also had a better balance (sensitivity 79.5%, specificity 83.3%) than the modified ESSG (sensitivity 79.1%, specificity 68.8%) and Amor criteria (sensitivity 67.5%, specificity 86.7%), respectively. CONCLUSIONS: The new ASAS classification criteria for peripheral SpA performed...

  18. Histopathology of valves in infective endocarditis, diagnostic criteria and treatment considerations.

    Science.gov (United States)

    Brandão, Tatiana J D; Januario-da-Silva, Carolina A; Correia, Marcelo G; Zappa, Monica; Abrantes, Jaime A; Dantas, Angela M R; Golebiovski, Wilma; Barbosa, Giovanna Ianini F; Weksler, Clara; Lamas, Cristiane C

    2017-04-01

    Infective endocarditis (IE) is a severe disease. Pathogen isolation is fundamental so as to treat effectively and reduce morbidity and mortality. Blood and valve culture and histopathology (HP) are routinely employed for this purpose. Valve HP is the gold standard for diagnosis. To determine the sensitivity and specificity of clinical criteria for IE (the modified Duke and the St Thomas' minor modifications, STH) of blood and valve culture compared to valve HP, and to evaluate antibiotic treatment duration. Prospective case series of patients, from 2006 to 2014 with surgically treated IE. Statistical analysis was done by the R software. There were 136 clinically definite episodes of IE in 133 patients. Mean age ± SD was 43 ± 15.6 years and IE was left sided in 81.6 %. HP was definite in 96 valves examined, which were used as gold standard. Sensitivity of blood culture was 61 % (CI 0.51, 0.71) and of valve culture 15 % (CI 0.07, 0.26). The modified Duke criteria were 65 % (CI 0.55, 0.75) sensitive and 33 % specific, while the STH's sensitivity was 72 % (CI 0.61, 0.80) with similar specificity. In multivariate analysis and logistic regression, the only variable with statistical significance was duration of antibiotic therapy postoperatively. Valve HP had high sensitivity and valve culture low sensitivity in the diagnosis of IE. The STH's criteria were more sensitive than the modified Duke criteria. Valve HP should guide duration of postoperative antibiotic treatment.

  19. Thin film organic photodetectors for indirect X-ray detection demonstrating low dose rate sensitivity at low voltage operation

    Energy Technology Data Exchange (ETDEWEB)

    Starkenburg, Daken J. [Department of Materials Science and Engineering, University of Florida, Gainesville, Florida 32611, USA; Johns, Paul M. [Nuclear Engineering Program, University of Florida, Gainesville, Florida 32611, USA; Detection Systems Group, Pacific Northwest National Laboratory, Richland, Washington 99354, USA; Baciak, James E. [Department of Materials Science and Engineering, University of Florida, Gainesville, Florida 32611, USA; Nuclear Engineering Program, University of Florida, Gainesville, Florida 32611, USA; Nino, Juan C. [Department of Materials Science and Engineering, University of Florida, Gainesville, Florida 32611, USA; Xue, Jiangeng [Department of Materials Science and Engineering, University of Florida, Gainesville, Florida 32611, USA

    2017-12-14

    Developments in the field of organic semiconductors have generated organic photodetectors with high quantum efficiency, wide spectral sensitivity, low power consumption, and unique form factors that are flexible and conformable to their substrate shape. In this work, organic photodetectors coupled with inorganic CsI(Tl) scintillators are used to showcase the low dose rate sensitivity that is enabled when high performance organic photodetectors and scintillator crystals are integrated. The detection capability of these organic-inorganic coupled systems to high energy radiation highlights their potential as an alternative to traditional photomultiplier tubes for nuclear spectroscopy applications. When exposed to Bremsstrahlung radiation produced from an X-ray generator, SubPc:C60, AlPcCl:C70, and P3HT:PC61BM thin film photodetectors with active layer thicknesses less than 100 nm show detection of incident radiation at low and no applied bias. Remarkably low dose rates, down to at least 0.28 µGy/s, were detectable with a characteristic linear relationship between exposure rate and photodetector current output. These devices also demonstrate sensitivities as high as 5.37 mC Gy-1 cm-2 when coupled to CsI(Tl). Additionally, as the tube voltage across the X-ray generator was varied, these organic-inorganic systems showed their ability to detect a range of continuous radiation spectra spanning several hundred keV.

  20. Determination of data correction coefficients and the sensitivities of the KIER air-borne gamma-ray spectrometer survey system

    International Nuclear Information System (INIS)

    Koo, J.H.; Cho, D.H.; Park, Y.S.

    1982-01-01

    In air-borne gamma-ray spectrometer survey, the observed data must be corrected for the background, Compton scattering and flight altitude. And the corrected data are usually converted into the radiometric elements equivalents of the ground, using the sensitivities of the survey system. Accordingly, the correction coefficients and the sensitivities are determined as follows for the KIER air-borne survey system. The stripping or Compton scattering coefficients α, β and γ at the ground level were first determined on the basis of the gamma-ray count rates due to the 5 concrete calibration pads of the Soosaek Airbase, together with the radiometric elements concentrations of the core samples taken from the pads. As for the determination of the exponential altitude coefficients anti μ(K), anti μ(U), anti μ(Th) and anti μ(Tc), the count rates observed over the Hongseong Test Strip of about 3 km length were used after they had been corrected for the background and Compton scattering. The background count rates mainly caused by the air-craft as well as cosmic radiations were determined with the data taken over the West Sea near Anmyon Island, Chung-cheongnam-do. And the corrected count rates observed over the Strip, combined with the average radiometric elements concentrations of the Strip, yielded the sensitivities k(K), k(U) and k(Th) at the 400 feet flight altitude. (author)

  1. Thin film organic photodetectors for indirect X-ray detection demonstrating low dose rate sensitivity at low voltage operation

    Science.gov (United States)

    Starkenburg, Daken J.; Johns, Paul M.; Baciak, James E.; Nino, Juan C.; Xue, Jiangeng

    2017-12-01

    Developments in the field of organic semiconductors have generated organic photodetectors with high quantum efficiency, wide spectral sensitivity, low power consumption, and unique form factors that are flexible and conformable to their substrate shape. In this work, organic photodetectors coupled with inorganic CsI(Tl) scintillators are used to showcase the low dose rate sensitivity that is enabled when high performance organic photodetectors and scintillator crystals are integrated. The detection capability of these organic-inorganic coupled systems to high energy radiation highlights their potential as an alternative to traditional photomultiplier tubes for nuclear spectroscopy applications. When exposed to Bremsstrahlung radiation produced from an X-ray generator, SubPc:C60, AlPcCl:C70, and P3HT:PC61BM thin film photodetectors with active layer thicknesses less than 100 nm show detection of incident radiation at low and no applied bias. Remarkably low dose rates, down to at least 0.18 μGy/s, were detectable with a characteristic linear relationship between exposure rate and photodetector current output. These devices also demonstrate sensitivities as high as 5.37 mC Gy-1 cm-2 when coupled to CsI(Tl). Additionally, as the tube voltage across the X-ray generator was varied, these organic-inorganic systems showed their ability to detect a range of continuous radiation spectra spanning several hundred keV.

  2. Time-of-flight position-sensitive x-ray detection

    International Nuclear Information System (INIS)

    Mowat, J.W.

    1981-01-01

    A new method for recording beam-foil time-of-flight data is described. A stationary, side-window, position-senstive proportional counter, oriented with anode wire parallel to the ion beam, views the decay in flight of excited ions through a Soller slit x-ray collimator. In contrast to the standard method, the exciter foil, placed within or upstream from the field of view, is not moved during the acquisition of a decay curve. Each point on the anode acts like an independent detector seeing a unique segment of the ion beam. The correspondence between the downstream distance at which an ion decays and the position along the anode at which the x-ray is detected makes a pulse-height spectrum of position pulses equivalent to a time-of-flight decay curve. Thus an entire decay curve can now be acquired without moving the foil. Increased efficiency is the most significant improvement over the standard method in which the radiation detector views only a small segment of the flight path at any one time. Experiments using translating foils are subject to a spurious dependence of x-ray intensity on foil position if the foil is non-uniform (or non-uniformly aged) and wobbles as it moves. This effect is eliminated here. Foil aging effects which influence excitation rates and introduce a slowly varying time dependence of the x-ray intensity are automatically normalized by this multichannel technique. The application of this method to metastable x-ray emitting states of low-Z ions are discussed

  3. A large-area, position-sensitive neutron detector with neutron/γ-ray discrimination capabilities

    International Nuclear Information System (INIS)

    Zecher, P.D.; Galonsky, A.; Kruse, J.J.; Gaff, S.J.; Ottarson, J.; Wang, J.; Seres, Z.; Ieki, K.; Iwata, Y.; Schelin, H.

    1997-01-01

    To further study neutron-rich halo nuclei, we have constructed a neutron detector array. The array consists of two separate banks of detectors, each of area 2 x 2 m 2 and containing 250 l of liquid scintillator. Each bank is position-sensitive to better than 10 cm. For neutron time-of-flight measurements, the time resolution of the detector has been demonstrated to be about 1 ns. By using the scintillator NE-213, we are able to distinguish between neutron and γ-ray signals above 1 MeV electron equivalent energy. Although the detector array was constructed for a particular experiment it has also been used in a number of other experiments. (orig.)

  4. X-ray sources

    International Nuclear Information System (INIS)

    Masswig, I.

    1986-01-01

    The tkb market survey comparatively evaluates the X-ray sources and replacement tubes for stationary equipment currently available on the German market. It lists the equipment parameters of 235 commercially available X-ray sources and their replacement tubes and gives the criteria for purchase decisions. The survey has been completed with December 1985, and offers good information concerning medical and technical aspects as well as those of safety and maintenance. (orig.) [de

  5. Photodiode array for position-sensitive detection using high X-ray flux provided by synchrotron radiation

    Science.gov (United States)

    Jucha, A.; Bonin, D.; Dartyge, E.; Flank, A. M.; Fontaine, A.; Raoux, D.

    1984-09-01

    Synchrotron radiation provides a high intensity source over a large range of wavelengths. This is the prominent quality that has laid the foundations of the EXAFS development (Extended X-ray Absorption Fine Structure). EXAFS data can be collected in different ways. A full scan requires 5 to 10 min, compared to the one-day data collection of a conventional Bremsstrahlung X-ray tube. Recently, by using the new photodiode array (R 1024 SFX) manufactured by Reticon, it has been possible to reduce the data collection time to less than 100 ms. The key elements of this new EXAFS method are a dispersive optics combined with a position sensitive detector able to work under very high flux conditions. The total aperture of 2500 μm × 25 μm for each pixel is well suited to spectroscopic applications. Besides its high dynamic range (> 10 4) and its linearity, the rapidity of the readout allows a flux of 10 9-10 10 photons/s over the 1024 sensing elements.

  6. Criteria for the choice of a monitoring equipment

    International Nuclear Information System (INIS)

    Wieters, C.U.

    1999-01-01

    The user of a monitor unit for the detection of radioactive nuclides in scrap has to study the conditions for his special installation. It is very important to verify the way and the transport units for the scrap. For example, scrap delivery by rail shows little variation of transport unit size, way and position of the wagon with the disadvantage of big scrap cargoes. Lorries have a large variation in size and it is very difficult to have good measuring condition (position, speed etc.). Only the size is normally a little bit smaller than by rail. The next is to find the best location on the site for the logistic and measuring conditions. It must be assured that all the delivered scrap passed by this point with a documentation. The optimum of detection and verification of the measurements has to be prepared. The criteria for the sensitivity of the detectors to the ionising radiation must be found. In our company we declare a shielded radioactive Cs-137 source with a high activity, normally used in radiometric measuring units, having a dose rate at the surface near 7.5 pSv/h. This metal bloc has to be found in all positions of the scrap cargo. The other criteria for the choice of the monitor: unit are the maintenance, the control of function, sensitivity and price. The first installation of the monitor unit has to be controlled by a specialist with tests. It is also recommended to install a documentation of all measured cargoes. With this documentation it will be assured that all cargoes are controlled, and it is easier to clarify the reasons of malfunction like vibration, other sources (ceramic, radiometric sources, etc.). On our site, we installed finally two types of detectors, first in 1995 for the scrap delivered by rail working in the standing position of the wagon on the weight bridge. Therefore a small CsI detector, which is very sensitive to gamma rays, was installed with the best positions around the scrap-wagon. Second, for the delivery by road through

  7. Characterization and evaluation of three groups of rice upland of different origins through gamma-ray sensitivity

    International Nuclear Information System (INIS)

    Rodrigues, Luis Roberto Franco

    2002-01-01

    The characterization and evaluation of varieties of rice aid in the parents selection and in the increase of the genetic base of breeding programs. The present work was carried out to characterize and to evaluate three groups of rice upland (Oryza sativa L.) of different origins through gamma-ray sensitivity. Seeds of 84 varieties collected from Japan, Philippines and Brazil, were submitted to various doses of gamma-radiation and sown in wooden boxes. The experiment was conducted in 1991 at greenhouse according to randomized complete block design with three replications. Physiological effects caused by radiation in the M 1 generation, such as seed emergency, seedling height and survival rate, were determined and evaluated. The results showed significant differences of sensitivity to the radiation among three groups for all traits evaluated. (author)

  8. Sensitivity of triple-crystal X-ray diffractometers to microdefects in silicon

    International Nuclear Information System (INIS)

    Molodkin, V.B.; Olikhovskii, S.I.; Len, E.G.; Kislovskii, E.N.; Kladko, V.P.; Reshetnyk, O.V.; Vladimirova, T.P.; Sheludchenko, B.V.

    2009-01-01

    The dynamical theory, which describes both diffraction profiles and reciprocal space maps measured from imperfect crystals with account for instrumental factors of triple-crystal diffractometer (TCD), has been developed for adequate quantitative characterization of microdefects. Analytical expressions for coherent and diffuse scattering (DS) intensities measured by TCD in the Bragg diffraction geometry have been derived by using the generalized statistical dynamical theory of X-ray scattering in real single crystals with randomly distributed defects. The DS intensity distributions from single crystals containing clusters and dislocation loops have been described by explicit analytical expressions. Particularly, these expressions take into account anisotropy of displacement fields around defects with discrete orientations. Characteristics of microdefect structures in silicon single crystals grown by Czochralsky- and float-zone methods have been determined by analyzing the measured TCD profiles and reciprocal space maps. The sensitivities of reciprocal space maps and diffraction profiles to defect characteristics have been compared. (Abstract Copyright [2009], Wiley Periodicals, Inc.)

  9. Low-resolution gamma-ray spectrometry for an information barrier based on a multi-criteria template-matching approach

    Energy Technology Data Exchange (ETDEWEB)

    Göttsche, Malte; Schirm, Janet; Glaser, Alexander

    2016-12-21

    Gamma-ray spectrometry has been successfully employed to identify unique items containing special nuclear materials. Template information barriers have been developed in the past to confirm items as warheads by comparing their gamma signature to the signature of true warheads. Their development has, however, not been fully transparent, and they may not be sensitive to some relevant evasion scenarios. We develop a fully open template information barrier concept, based on low-resolution measurements, which, by design, reduces the extent of revealed sensitive information. The concept is based on three signatures of an item to be compared to a recorded template. The similarity of the spectrum is assessed by a modification of the Kolmogorov–Smirnov test to confirm the isotopic composition. The total gamma count rate must agree with the template as a measure of the projected surface of the object. In order to detect the diversion of fissile material from the interior of an item, a polyethylene mask is placed in front of the detector. Neutrons from spontaneous and induced fission events in the item produce 2.223 MeV gamma rays from neutron capture by hydrogen-1 in the mask. This peak is detected and its intensity scales with the item's fissile mass. The analysis based on MCNP Monte Carlo simulations of various plutonium configurations suggests that this concept can distinguish a valid item from a variety of invalid ones. The concept intentionally avoids any assumptions about specific spectral features, such as looking for specific gamma peaks of specific isotopes, thereby facilitating a fully unclassified discussion. By making all aspects public and allowing interested participants to contribute to the development and benchmarking, we enable a more open and inclusive discourse on this matter.

  10. Statistical survey of ten criteria established by Portaria 453 of Brazilian Ministry of Health for dentists who use X-rays

    International Nuclear Information System (INIS)

    Almeida, Claudio Domingues de

    2005-01-01

    In July 1998, the Ministry of Health (MS) published the Guidelines for Radiological Protection in Medical and Dental Radiodiagnosis that became known as Portaria 453 - Ordinance 453. This study is designed to evaluate the dentists of Rio de Janeiro on the knowledge and application of the criteria laid down by Ordinance. For this, it was sent to dentists, a form with 13 questions. The issues are related to the use of personal protective clothing (VPI), working procedures for the exam and processing of the image, radioprotection training and quality control. Of 1528 dentists, only 40% have a copy of the Ordinance. Regarding the use of VPI, 94% has lead apron and 76% thyroid shield. Only 63% of dentists observe patients during exposure to X-rays. In 96% of doctor's rooms the revelation of the film is made in a portable box, 71% of these use the visual method to stop processing. The results show the need for greater dissemination of the Ordinance by the odontologist's associations; for an educational work on the topics discussed and training that allow the dentists be prepared to apply the correct work procedures in the production of diagnostic imaging with X-rays

  11. Airborne gamma-ray spectrometer and magnetometer survey, Point Lay Quadrangle, Alaska. Volume I. Final report

    International Nuclear Information System (INIS)

    1981-02-01

    The results obtained from an airborne high sensitivity gamma-ray spectrometer and magnetometer survey over the Point Lay map area of Alaska are presented. Based on the criteria outlined in the general section on interpretation, a total of six uranium anomalies have been indicated on the interpretation map. All six are only weakly to moderately anomalous in either uranium or the uranium ratios. None of these are thought to be of any economic significance. No follow-up work is recommended for the Point Lay Quadrangle

  12. Fluorescence detection of white-beam X-ray absorption anisotropy: towards element-sensitive projections of local atomic structure

    International Nuclear Information System (INIS)

    Korecki, P.; Tolkiehn, M.; Dąbrowski, K. M.; Novikov, D. V.

    2011-01-01

    A method for a direct measurement of X-ray projections of the atomic structure is described. Projections of the atomic structure around Nb atoms in a LiNbO 3 single crystal were obtained from a white-beam X-ray absorption anisotropy pattern detected using Nb K fluorescence. Projections of the atomic structure around Nb atoms in a LiNbO 3 single crystal were obtained from a white-beam X-ray absorption anisotropy (XAA) pattern detected using Nb K fluorescence. This kind of anisotropy results from the interference of X-rays inside a sample and, owing to the short coherence length of a white beam, is visible only at small angles around interatomic directions. Consequently, the main features of the recorded XAA corresponded to distorted real-space projections of dense-packed atomic planes and atomic rows. A quantitative analysis of XAA was carried out using a wavelet transform and allowed well resolved projections of Nb atoms to be obtained up to distances of 10 Å. The signal of nearest O atoms was detected indirectly by a comparison with model calculations. The measurement of white-beam XAA using characteristic radiation indicates the possibility of obtaining element-sensitive projections of the local atomic structure in more complex samples

  13. Synchrotron x-ray microbeam characteristics for x-ray fluorescence analysis

    International Nuclear Information System (INIS)

    Iida, Atsuo; Noma, Takashi

    1995-01-01

    X-ray fluorescence analysis using a synchrotron x-ray microprobe has become an indispensable technique for non-destructive micro-analysis. One of the most important parameters that characterize the x-ray microbeam system for x-ray fluorescence analysis is the beam size. For practical analysis, however, the photon flux, the energy resolution and the available energy range are also crucial. Three types of x-ray microbeam systems, including monochromatic and continuum excitation systems, were compared with reference to the sensitivity, the minimum detection limit and the applicability to various types of x-ray spectroscopic analysis. 16 refs., 5 figs

  14. Analysis of patterns of three-phase bone scintigraphy for patients with complex regional pain syndrome diagnosed using the proposed research criteria (the 'Budapest Criteria').

    Science.gov (United States)

    Moon, J Y; Park, S Y; Kim, Y C; Lee, S C; Nahm, F S; Kim, J H; Kim, H; Oh, S W

    2012-04-01

    Three-phase bone scintigraphy (TPBS) is an established objective diagnostic method for complex regional pain syndrome (CRPS), but its validity remains controversial. The aims of this study were: (i) to re-evaluate the diagnostic performance of TPBS, and (ii) to suggest new TPBS criteria based on the proposed research criteria for CPRS in Budapest (the 2003 Budapest research criteria). The medical records of 228 consecutive patients, evaluated using the Budapest research criteria, were retrospectively analysed. Of these, 116 patients were included in the present study, and 69 of 116 were diagnosed to have CRPS based on these criteria. The diagnostic performance of TPBS was assessed by determining its sensitivity, specificity, and positive and negative likelihood ratios, and new criteria for TPBS were identified by pattern analysis using the Budapest research criteria. The sensitivity, specificity, positive likelihood ratio, and negative likelihood ratio of TPBS for the diagnosis of CRPS according to the Budapest research criteria were 40.0, 76.5, 1.73, and 0.78, respectively. Furthermore, D-D-D, D-D-S, and D-D-I patterns [i.e. according to decreased (D), symmetrical (S), or increased (I) tracer uptake during Phases I, II, and III] of TPBS were found to be positively predictive for CRPS. The diagnostic value of a positive TPBS for CRPS is low from the view point of the Budapest research criteria. Our findings suggest that a diagnosis of CRPS using the Budapest research criteria should be considered when decreased patterns of TPBS are observed during Phases I and II.

  15. Formal MRI criteria for the diagnosis of multiple sclerosis

    International Nuclear Information System (INIS)

    Harting, I.; Haehnel, S.; Meyding-Lamade, U.

    2004-01-01

    Multiple scloris (MS) is the most common demyelinating inflammatory disease of the central nervous system, presenting with multifocal, disseminated white matter lesions called plaques. Magnetic resonance imaging (MRI) is very sensitive in detecting white matter abnormalities. By demonstrating the spatial and temporal dissemination in patients presenting with isolated clinical findings suggestive of MS, MRI contributes to estimating the likelihood of the disease. Since MRI is highly sensitive but not specific, it is important to apply formal MRI criteria. This article describes the characteristic MRI changes of MS and the so-called McDonald criteria for an MRI-supported diagnosis of MS. (orig.) [de

  16. Computed tomographic angiography criteria in the diagnosis of brain death - comparison of sensitivity and interobserver reliability of different evaluation scales

    Energy Technology Data Exchange (ETDEWEB)

    Sawicki, Marcin; Walecka, A. [Pomeranian Medical University, Department of Diagnostic Imaging and Interventional Radiology, Szczecin (Poland); Bohatyrewicz, R.; Solek-Pastuszka, J. [Pomeranian Medical University, Clinic of Anesthesiology and Intensive Care, Szczecin (Poland); Safranow, K. [Pomeranian Medical University, Department of Biochemistry and Medical Chemistry, Szczecin (Poland); Walecki, J. [The Centre of Postgraduate Medical Education, Warsaw (Poland); Rowinski, O. [Medical University of Warsaw, 2nd Department of Clinical Radiology, Warsaw (Poland); Czajkowski, Z. [Regional Joint Hospital, Szczecin (Poland); Guzinski, M. [Wroclaw Medical University, Department of General Radiology, Interventional Radiology and Neuroradiology, Wroclaw (Poland); Burzynska, M. [Wroclaw Medical University, Department of Anesthesiology and Intensive Therapy, Wroclaw (Poland); Wojczal, J. [Medical University of Lublin, Department of Neurology, Lublin (Poland)

    2014-08-15

    The standardized diagnostic criteria for computed tomographic angiography (CTA) in diagnosis of brain death (BD) are not yet established. The aim of the study was to compare the sensitivity and interobserver agreement of the three previously used scales of CTA for the diagnosis of BD. Eighty-two clinically brain-dead patients underwent CTA with a delay of 40 s after contrast injection. Catheter angiography was used as the reference standard. CTA results were assessed by two radiologists, and the diagnosis of BD was established according to 10-, 7-, and 4-point scales. Catheter angiography confirmed the diagnosis of BD in all cases. Opacification of certain cerebral vessels as indicator of BD was highly sensitive: cortical segments of the middle cerebral artery (96.3 %), the internal cerebral vein (98.8 %), and the great cerebral vein (98.8 %). Other vessels were less sensitive: the pericallosal artery (74.4 %), cortical segments of the posterior cerebral artery (79.3 %), and the basilar artery (82.9 %). The sensitivities of the 10-, 7-, and 4-point scales were 67.1, 74.4, and 96.3 %, respectively (p < 0.001). Percentage interobserver agreement in diagnosis of BD reached 93 % for the 10-point scale, 89 % for the 7-point scale, and 95 % for the 4-point scale (p = 0.37). In the application of CTA to the diagnosis of BD, reducing the assessment of vascular opacification scale from a 10- to a 4-point scale significantly increases the sensitivity and maintains high interobserver reliability. (orig.)

  17. Computed tomographic angiography criteria in the diagnosis of brain death - comparison of sensitivity and interobserver reliability of different evaluation scales

    International Nuclear Information System (INIS)

    Sawicki, Marcin; Walecka, A.; Bohatyrewicz, R.; Solek-Pastuszka, J.; Safranow, K.; Walecki, J.; Rowinski, O.; Czajkowski, Z.; Guzinski, M.; Burzynska, M.; Wojczal, J.

    2014-01-01

    The standardized diagnostic criteria for computed tomographic angiography (CTA) in diagnosis of brain death (BD) are not yet established. The aim of the study was to compare the sensitivity and interobserver agreement of the three previously used scales of CTA for the diagnosis of BD. Eighty-two clinically brain-dead patients underwent CTA with a delay of 40 s after contrast injection. Catheter angiography was used as the reference standard. CTA results were assessed by two radiologists, and the diagnosis of BD was established according to 10-, 7-, and 4-point scales. Catheter angiography confirmed the diagnosis of BD in all cases. Opacification of certain cerebral vessels as indicator of BD was highly sensitive: cortical segments of the middle cerebral artery (96.3 %), the internal cerebral vein (98.8 %), and the great cerebral vein (98.8 %). Other vessels were less sensitive: the pericallosal artery (74.4 %), cortical segments of the posterior cerebral artery (79.3 %), and the basilar artery (82.9 %). The sensitivities of the 10-, 7-, and 4-point scales were 67.1, 74.4, and 96.3 %, respectively (p < 0.001). Percentage interobserver agreement in diagnosis of BD reached 93 % for the 10-point scale, 89 % for the 7-point scale, and 95 % for the 4-point scale (p = 0.37). In the application of CTA to the diagnosis of BD, reducing the assessment of vascular opacification scale from a 10- to a 4-point scale significantly increases the sensitivity and maintains high interobserver reliability. (orig.)

  18. Human factors engineering design review acceptance criteria for the safety parameter display

    International Nuclear Information System (INIS)

    McGevna, V.; Peterson, L.R.

    1981-01-01

    This report contains human factors engineering design review acceptance criteria developed by the Human Factors Engineering Branch (HFEB) of the Nuclear Regulatory Commission (NRC) to use in evaluating designs of the Safety Parameter Display System (SPDS). These criteria were developed in response to the functional design criteria for the SPDS defined in NUREG-0696, Functional Criteria for Emergency Response Facilities. The purpose of this report is to identify design review acceptance criteria for the SPDS installed in the control room of a nuclear power plant. Use of computer driven cathode ray tube (CRT) displays is anticipated. General acceptance criteria for displays of plant safety status information by the SPDS are developed. In addition, specific SPDS review criteria corresponding to the SPDS functional criteria specified in NUREG-0696 are established

  19. SENDS criteria from the diversification of MAST procedures. Implementation of preoperative simulation

    International Nuclear Information System (INIS)

    Rieger, B.

    2015-01-01

    Minimal access spinal technologies (MAST) lead to a diversification of surgical procedures, which requires careful selection of the procedure and outcome monitoring. For a rational selection of the procedure simulation, endoscopy, navigation, decompression and stabilization (SENDS) criteria can be derived from the development of the MAST procedures. Preoperative simulation has diagnostic and therapeutic values. The SENDS criteria can be verified indirectly via outcome control. Biomechanically meaningful diagnostic x-rays of the spinal segment to be surgically treated are currently carried out with the patient in inclination and reclination. Software-related preoperative simulation based on these x-ray images facilitates the selection and implementation of the MAST procedure. For preoperative simulation motion shots are needed in inclination, neutral position and reclination and the dimensions can be obtained using an x-ray ball or a computed tomography (CT) scan. The SENDS criteria are useful because established procedures based on these criteria reach a comparable outcome. Preoperative simulation appears to be a useful selection criterion. Preoperatively it is necessary to collate patient and segment information in order to provide each patient with individualized treatment. So far there is no evidence for a better outcome after preoperative simulation but a reduction of surgery time and intraoperative radiation exposure could already be demonstrated. Minimally invasive methods should be preferred if there is a comparable outcome. The establishment of new procedures has to be accompanied by the maintenance of a spine register. Minimally invasive surgical procedures should be individualized for each patient and segment. Mobility X-ray images should be prepared for use with the preoperative simulation as the information content significantly increases with respect to the MAST procedure. (orig.) [de

  20. Do MCI criteria in drug trials accurately identify subjects with predementia Alzheimer's disease?

    Science.gov (United States)

    Visser, P; Scheltens, P; Verhey, F

    2005-01-01

    Background: Drugs effective in Alzheimer-type dementia have been tested in subjects with mild cognitive impairment (MCI) because these are supposed to have Alzheimer's disease in the predementia stage. Objectives: To investigate whether MCI criteria used in these drug trials can accurately diagnose subjects with predementia Alzheimer's disease. Methods: MCI criteria of the Gal-Int 11 study, InDDEx study, ADCS memory impairment study, ampakine CX 516 study, piracetam study, and Merck rofecoxib study were applied retrospectively in a cohort of 150 non-demented subjects from a memory clinic. Forty two had progressed to Alzheimer type dementia during a five year follow up period and were considered to have predementia Alzheimer's disease at baseline. Outcome measures were the odds ratio, sensitivity, specificity, and positive and negative predictive value. Results: The odds ratio of the MCI criteria for predementia Alzheimer's disease varied between 0.84 and 11. Sensitivity varied between 0.46 and 0.83 and positive predictive value between 0.43 and 0.76. None of the criteria combined a high sensitivity with a high positive predictive value. Exclusion criteria for depression led to an increase in positive predictive value and specificity at the cost of sensitivity. In subjects older than 65 years the positive predictive value was higher than in younger subjects. Conclusions: The diagnostic accuracy of MCI criteria used in trials for predementia Alzheimer's disease is low to moderate. Their use may lead to inclusion of many patients who do not have predementia Alzheimer's disease or to exclusion of many who do. Subjects with moderately severe depression should not be excluded from trials in order not to reduce the sensitivity. PMID:16170074

  1. Variable X-ray sky with Lobster Eye Telescopes

    International Nuclear Information System (INIS)

    Hudec, R.; Pina, L.; Inneman, A.; Sveda, L.

    2004-01-01

    The variable X-ray sky requires wide-field monitoring with high sensitivity. We refer on novel X-ray telescopes with high sensitivity as well as large field of view. The results are very promising, allowing the proposals for space projects with very wide-field Lobster-eye X-ray optics to be considered. The novel telescopes will monitor the sky with unprecedented sensitivity and angular resolution of order of 1 arcmin. They are expected to contribute essentially to study and to understand various astrophysical objects such as AGN, SNe, GRBs, X-ray flashes, galactic binary sources, stars, CVs, X-ray novae, various transient sources, etc

  2. Chromosome condensation may enhance X-ray-related cell lethality in a temperature-sensitive mutant (tsBN2) of baby hamster kidney cells (BHK21)

    International Nuclear Information System (INIS)

    Sasaki, H.; Nishimoto, T.

    1987-01-01

    In the tsBN2 cell line, which has a temperature-sensitive defect in the regulatory mechanism for chromosome condensation, the lethal effect of X rays was enhanced by incubating the cells at a nonpermissive temperature (40 degrees C) following X irradiation. This enhancement was suppressed in the presence of cycloheximide, which inhibits induction of premature chromosome condensation. The findings obtained in the case of delayed incubation at 40 degrees C and in synchronized cells indicate that X-ray-related potentially lethal damage, which can be expressed by chromosome condensation, is produced in the cells at any stage of the cell cycle, but it is repairable for all cells except those at around the late G2-M phase, where chromosome condensation occurs at a permissive temperature (33.5 degrees C). These observations suggest that the high sensitivity of late G2-M cells to X rays is caused by the events associated with chromosome condensation

  3. Energy dependence corrections to MOSFET dosimetric sensitivity

    International Nuclear Information System (INIS)

    Cheung, T.; Yu, P.K.N.; Butson, M.J.; Illawarra Cancer Care Centre, Crown St, Wollongong

    2009-01-01

    Metal Oxide Semiconductor Field Effect Transistors (MOSFET's) are dosimeters which are now frequently utilized in radiotherapy treatment applications. An improved MOSFET, clinical semiconductor dosimetry system (CSDS) which utilizes improved packaging for the MOSFET device has been studied for energy dependence of sensitivity to x-ray radiation measurement. Energy dependence from 50 kVp to 10 MV x-rays has been studied and found to vary by up to a factor of 3.2 with 75 kVp producing the highest sensitivity response. The detectors average life span in high sensitivity mode is energy related and ranges from approximately 100 Gy for 75 kVp x-rays to approximately 300 Gy at 6MV x-ray energy. The MOSFET detector has also been studied for sensitivity variations with integrated dose history. It was found to become less sensitive to radiation with age and the magnitude of this effect is dependant on radiation energy with lower energies producing a larger sensitivity reduction with integrated dose. The reduction in sensitivity is however approximated reproducibly by a slightly non linear, second order polynomial function allowing corrections to be made to reading to account for this effect to provide more accurate dose assessments both in phantom and in-vivo.

  4. Energy dependence corrections to MOSFET dosimetric sensitivity.

    Science.gov (United States)

    Cheung, T; Butson, M J; Yu, P K N

    2009-03-01

    Metal Oxide Semiconductor Field Effect Transistors (MOSFET's) are dosimeters which are now frequently utilized in radiotherapy treatment applications. An improved MOSFET, clinical semiconductor dosimetry system (CSDS) which utilizes improved packaging for the MOSFET device has been studied for energy dependence of sensitivity to x-ray radiation measurement. Energy dependence from 50 kVp to 10 MV x-rays has been studied and found to vary by up to a factor of 3.2 with 75 kVp producing the highest sensitivity response. The detectors average life span in high sensitivity mode is energy related and ranges from approximately 100 Gy for 75 kVp x-rays to approximately 300 Gy at 6 MV x-ray energy. The MOSFET detector has also been studied for sensitivity variations with integrated dose history. It was found to become less sensitive to radiation with age and the magnitude of this effect is dependant on radiation energy with lower energies producing a larger sensitivity reduction with integrated dose. The reduction in sensitivity is however approximated reproducibly by a slightly non linear, second order polynomial function allowing corrections to be made to readings to account for this effect to provide more accurate dose assessments both in phantom and in-vivo.

  5. Observations of the highest energy gamma-rays from gamma-ray bursts

    International Nuclear Information System (INIS)

    Dingus, Brenda L.

    2001-01-01

    EGRET has extended the highest energy observations of gamma-ray bursts to GeV gamma rays. Such high energies imply the fireball that is radiating the gamma-rays has a bulk Lorentz factor of several hundred. However, EGRET only detected a few gamma-ray bursts. GLAST will likely detect several hundred bursts and may extend the maximum energy to a few 100 GeV. Meanwhile new ground based detectors with sensitivity to gamma-ray bursts are beginning operation, and one recently reported evidence for TeV emission from a burst

  6. Multi-step contrast sensitivity gauge

    Science.gov (United States)

    Quintana, Enrico C; Thompson, Kyle R; Moore, David G; Heister, Jack D; Poland, Richard W; Ellegood, John P; Hodges, George K; Prindville, James E

    2014-10-14

    An X-ray contrast sensitivity gauge is described herein. The contrast sensitivity gauge comprises a plurality of steps of varying thicknesses. Each step in the gauge includes a plurality of recesses of differing depths, wherein the depths are a function of the thickness of their respective step. An X-ray image of the gauge is analyzed to determine a contrast-to-noise ratio of a detector employed to generate the image.

  7. Correlation of radiation sensitivity and nitrofurantoin sensitivity of Escherichia coli K-12

    International Nuclear Information System (INIS)

    Kloeck, K.

    1981-01-01

    The Uvr- and rec-mutants of E.coli K-12 have been tested with a view to their radiation- and nitrofuration sensitivity. The tests showed that all mutants tested were more radiation- and NF-sensitive than the wild type AB 1157. When the NF-sensitivity had been compared to the UV- and X-ray sensitivity it became obvious that the NF-sensitivity is correlated to the UV-sensitivity. Studies carried out with regard to the time dependence of the NF-effect on E.coli showed that the effect of NF on E. Coli became weaker after about 1 1/2 to 2 hours. That is possibly caused by the fact that the E. coli bacteria succeed in reducing the NF to an inactive form. By means of nitrosoguanidine mutants of E-coli AB 1157 had been induced and by means of the Replicite Plating Method, NF-sensible mutants had been isolated from the plutonium mixture. Among the mutants which had been isolated by this method, 74% had been more UV-sensitive than the wild type and 55% more X-ray sensitive. Thus NF-sensitive mutants have not necessarily to be considered as rec-mutants as there are also uvr-mutants in the mixture. (orig.) [de

  8. Ventilator-Associated Pneumonia in Trauma Patients: Different Criteria, Different Rates.

    Science.gov (United States)

    Leonard, Kenji L; Borst, Gregory M; Davies, Stephen W; Coogan, Michael; Waibel, Brett H; Poulin, Nathaniel R; Bard, Michael R; Goettler, Claudia E; Rinehart, Shane M; Toschlog, Eric A

    2016-06-01

    No consensus exists regarding the definition of ventilator-associated pneumonia (VAP). Even within a single institution, inconsistent diagnostic criteria result in conflicting rates of VAP. As a Level 1 trauma center participating in the Trauma Quality Improvement Project (TQIP) and the National Healthcare Safety Network (NHSN), our institution showed inconsistencies in VAP rates depending on which criteria was applied. The purpose of this study was to compare VAP definitions, defined by culture-based criteria, National Trauma Data Bank (NTDB) and NHSN, using incidence in trauma patients. A retrospective chart review of consecutive trauma patients who were diagnosed with VAP and met pre-determined inclusion and exclusion criteria admitted to our rural, 861-bed, Level 1 trauma and tertiary care center between January 2008 and December 2011 was performed. These patients were identified from the National Trauma Registry of the American College of Surgeons (NTRACS) database and an in-house infection control database. Ventilator-associated pneumonia diagnosis criteria defined by the U.S. Center for Disease Control and Prevention (used by the NHSN), the NTDB, and our institutional, culture-based criteria gold standard were compared among patients. Two hundred seventy-nine patients were diagnosed with VAP (25.4% met NHSN criteria, 88.2% met NTDB, and 76.3% met culture-based criteria). Only 58 (20.1%) patients met all three criteria. When NHSN criteria were compared with culture-based criteria, NHSN showed a high specificity (92.5%) and low sensitivity (28.2%). The positive predictive value (PPV) was 84.5%, but the negative predictive value (NPV) was 47.1%. The agreement between the NHSN and the culture-based criteria was poor (κ = 0.18). Conversely, the NTDB showed a lower specificity (57.8%), but greater sensitivity (86.4%) compared with culture-based criteria. The PPV and NPV were both 74% and the two criteria showed fair agreement (κ = 0.41). The lack of

  9. Position-sensitive X-ray detectors

    International Nuclear Information System (INIS)

    Hendrix, J.

    1982-01-01

    In this review of the application of different types of position sensitive detectors to synchrotron radiation, discussion of the proportional counters based on the gas amplification principle forms a major part. Other topics reviewed are detector requirements, multiwire proportional chamber system, drift chamber type detectors, TV detectors, and recent developments, such as that based on a micro-channel plate as the amplifying element, and charge-coupled devices. (U.K.)

  10. Sensitivities and detection limits of X-ray fluorescence analysis with a 10 mCi241Am source

    International Nuclear Information System (INIS)

    Wundt, K.; Janghorbani, M.; Starke, K.

    1976-01-01

    Seven trace elements ranging from chromium to barium were preconcentrated on Amberlite IR-120 cation exchange paper and determined in an energy dispersive X-ray fluorescence system using a 10 mCi 241 Am source. Sensitivities were experimentally determined and checked with theoretically calculated values. The detection limits are compared with elemental levels present in typical surface waters and those allowed in drinking water. Appropriate conclusions as to feasibility of such a system for environmental monitoring are drawn. (orig.) [de

  11. [Revision of McDonald's new diagnostic criteria for multiple sclerosis].

    Science.gov (United States)

    Wiendl, H; Kieseier, B C; Gold, R; Hohlfeld, R; Bendszus, M; Hartung, H-P

    2006-10-01

    In 2001, an international panel suggested new diagnostic criteria for multiple sclerosis (MS). These criteria integrate clinical, imaging (MRI), and paraclinical results in order to facilitate diagnosis. Since then, these so-called McDonald criteria have been broadly accepted and widely propagated. In the meantime a number of publications have dealt with the sensitivity and specificity for MS diagnosis and with implementing these new criteria in clinical practice. Based on these empirical values and newer data on MS, an international expert group recently proposed a revision of the criteria. Substantial changes affect (1) MRI criteria for the dissemination of lesions over time, (2) the role of spinal cord lesions in the MRI and (3) diagnosis of primary progressive MS. In this article we present recent experiences with the McDonald and revised criteria.

  12. Digital Interface Modules for Active-Readout X-Ray Spectrometer.

    Science.gov (United States)

    1985-03-01

    x - ray sensitivity. The x - ray absorption coefficients tabulated by McMasters , et al...provides x - ray spectrographic data with all instrument response factors removed. v %, . % CONVERSION TABLE CONVERSION FACTORS FOR U.S. CUSTOMARY TO METRIC...LLNL document UCRL-50174) have been used to calculate the values of TKIM and TBe listed in Tables 1 through 3. The Reticon x - ray sensitivity

  13. High-Resolution Detector For X-Ray Diffraction

    Science.gov (United States)

    Carter, Daniel C.; Withrow, William K.; Pusey, Marc L.; Yost, Vaughn H.

    1988-01-01

    Proposed x-ray-sensitive imaging detector offers superior spatial resolution, counting-rate capacity, and dynamic range. Instrument based on laser-stimulated luminescence and reusable x-ray-sensitive film. Detector scans x-ray film line by line. Extracts latent image in film and simultaneously erases film for reuse. Used primarily for protein crystallography. Principle adapted to imaging detectors for electron microscopy and fluorescence spectroscopy and general use in astronomy, engineering, and medicine.

  14. Swift: A gamma ray burst MIDEX

    International Nuclear Information System (INIS)

    Barthelmy, Scott

    2001-01-01

    Swift is a first of its kind multiwavelength transient observatory for gamma-ray burst astronomy. It has the optimum capabilities for the next breakthroughs in determining the origin of gamma-ray bursts and their afterglows as well as using bursts to probe the early Universe. Swift will also perform the first sensitive hard X-ray survey of the sky. The mission is being developed by an international collaboration and consists of three instruments, the Burst Alert Telescope (BAT), the X-ray Telescope (XRT), and the Ultraviolet and Optical Telescope (UVOT). The BAT, a wide-field gamma-ray detector, will detect ∼1 gamma-ray burst per day with a sensitivity 5 times that of BATSE. The sensitive narrow-field XRT and UVOT will be autonomously slewed to the burst location in 20 to 70 seconds to determine 0.3-5.0 arcsec positions and perform optical, UV, and X-ray spectrophotometry. On-board measurements of redshift will also be done for hundreds of bursts. Swift will incorporate superb, low-cost instruments using existing flight-spare hardware and designs. Strong education/public outreach and follow-up programs will help to engage the public and astronomical community. Swift has been selected by NASA for development and launch in late 2003

  15. Objective CT criteria to determine the presence of abnormal basal enhancement in children with suspected tuberculous meningitis

    International Nuclear Information System (INIS)

    Przybojewski, Stefan; Andronikou, Savvas; Wilmshurst, Jo

    2006-01-01

    There are no widely accepted objective criteria to determine the presence of basal enhancement on CT in children with suspected tuberculous meningitis (TBM). To test nine recently described objective CT criteria for the presence of abnormal basal enhancement in children with suspected TBM against the definite diagnosis as determined by cerebrospinal fluid (CSF) culture. CT scans of patients with a clinical suspicion of TBM who had undergone lumbar puncture for CSF culture spanning a period of 4 years were reviewed for the presence of nine recently described criteria for the presence of abnormal basal enhancement. The radiologists were blinded to the final diagnosis based on CSF culture against which the criteria were tested. The criteria have been named: the 'Y-sign', 'linear enhancement', 'double lines', 'infundibular recess of the third', 'ill-defined edge', 'nodular enhancement', 'join the dots', 'contrast filling the cisterns', and 'asymmetry'. A total of 65 patients were included in the study, 34 with culture-proven TBM and 31 with other diagnoses. Four individual criteria had a specificity of 100%, but the sensitivities of these criteria ranged from 15% to 53% only. Three other criteria had specificities of 97% and sensitivities ranging from 62% to 82%. The presence of more than one criterion in the same patient showed a specificity of 97% and sensitivity of 91%. Very high specificity was demonstrated for all nine criteria, including 100% specificity for four individual criteria. Sensitivity was at best 82%, but improved to 91% when more than one criterion was present. These criteria need to be tested for inter- and intraobserver variability to prove their clinical usefulness. (orig.)

  16. Two digital X-ray imaging systems for applications in X-ray diffraction

    International Nuclear Information System (INIS)

    Bateman, J.E.; Connolly, J.F.; Stephenson, R.; Flesher, A.C.; Bryant, C.J.; Lincoln, A.D.; Tucker, P.A.; Swanton, S.W.

    1986-08-01

    Two digital X-ray imaging systems developed at the Rutherford Appleton Laboratory are described:- the Mark I and the Mark II. Both use a bidimensionally sensitive Multiwire proportional counter as the basic X-ray image transducer coupled to a digital microcomputer system. The Mark I system provides the advantages of high speed, high sensitivity digital imaging directly into the computer with the potential for software control of the sample orientation and environment. The Mark II system adds the novel features of signal averaging and multi-frame exposures. (author)

  17. Noise and sensitivity of x-ray framing cameras at Nike (abstract)

    Science.gov (United States)

    Pawley, C. J.; Deniz, A. V.; Lehecka, T.

    1999-01-01

    X-ray framing cameras are the most widely used tool for radiographing density distributions in laser and Z-pinch driven experiments. The x-ray framing cameras that were developed specifically for experiments on the Nike laser system are described. One of these cameras has been coupled to a CCD camera and was tested for resolution and image noise using both electrons and x rays. The largest source of noise in the images was found to be due to low quantum detection efficiency of x-ray photons.

  18. Predicting criteria continuous concentrations of 34 metals or metalloids by use of quantitative ion character-activity relationships–species sensitivity distributions (QICAR–SSD) model

    International Nuclear Information System (INIS)

    Mu, Yunsong; Wu, Fengchang; Chen, Cheng; Liu, Yuedan; Zhao, Xiaoli; Haiqing Liao; Giesy, John P.

    2014-01-01

    Criteria continuous concentrations (CCCs) are useful for describing chronic exposure to pollutants and setting water quality standards to protect aquatic life. However, because of financial, practical, or ethical restrictions on toxicity testing, few data are available to derive CCCs. In this study, CCCs for 34 metals or metalloids were derived using quantitative ion character-activity relationships–species sensitivity distributions (QICAR–SSD) and the final acute-chronic ratio (FACR) method. The results showed that chronic toxic potencies were correlated with several physico-chemical properties among eight species chosen, where the softness index was the most predictive characteristic. Predicted CCCs for most of the metals, except for Lead and Iron, were within a range of 10-fold of values recommended by the U.S. EPA. The QICAR–SSD model was superior to the FACR method for prediction of data-poor metals. This would have significance for predicting toxic potencies and criteria thresholds of more metals or metalloids. - Highlights: • We investigate relationships between σp and log-NOEC in eight species. • The QICAR–SSD model, FACR, and CMC/CCC were used to predict CCCs. • They are as a supplement to screening for toxicities, criteria and standards. - CCCs for 34 metals/metalloids were predicted by use of QICAR–SSD model and FACR method

  19. Development of an ionization chamber based high sensitivity detector for the measurement of radiation dose from X-ray whole body scanners

    International Nuclear Information System (INIS)

    Singh, Sunil K.; Tripathi, S.M.; LijiShaiju; Sathian, V.; Kulkarni, M.S.

    2016-01-01

    Using walk through metal detectors and undergoing frisking for personals at airports, seaports, railway stations and other sensitive places no longer meets proper security requirements. Now a days use of plastic explosives, drug trafficking or illegal carriage of dangerous items concealed under cloths or body cavities has increased many folds which in many cases is not possible to detect by conventional methods. One of the systems which are capable to overcome the above mentioned difficulties is the use of X-ray based whole body scanners, either transmission type or backscatter type, depending upon the nature of requirement. While using these whole body scanners the person being scanned possesses a radiation risk whose safety aspects can be monitored by following international standards (recommending certain dose limits). In order to check the compliance of these dose limits, the dose per scan received by the person (from these whole body scanners) needs to be measured. A very high sensitive ionization chamber has been designed and fabricated for measuring these extremely low X- ray fields ( few μR) produced by a scanning X-ray beam over a large area. A methodology has been developed to measure exposure per scan using large volume ionization chambers. This value of exposure was used to calculate whole body dose as per the recommendations of ANSI standard for its compliance

  20. Predicting criteria continuous concentrations of 34 metals or metalloids by use of quantitative ion character-activity relationships-species sensitivity distributions (QICAR-SSD) model.

    Science.gov (United States)

    Mu, Yunsong; Wu, Fengchang; Chen, Cheng; Liu, Yuedan; Zhao, Xiaoli; Haiqing Liao; Giesy, John P

    2014-05-01

    Criteria continuous concentrations (CCCs) are useful for describing chronic exposure to pollutants and setting water quality standards to protect aquatic life. However, because of financial, practical, or ethical restrictions on toxicity testing, few data are available to derive CCCs. In this study, CCCs for 34 metals or metalloids were derived using quantitative ion character-activity relationships-species sensitivity distributions (QICAR-SSD) and the final acute-chronic ratio (FACR) method. The results showed that chronic toxic potencies were correlated with several physico-chemical properties among eight species chosen, where the softness index was the most predictive characteristic. Predicted CCCs for most of the metals, except for Lead and Iron, were within a range of 10-fold of values recommended by the U.S. EPA. The QICAR-SSD model was superior to the FACR method for prediction of data-poor metals. This would have significance for predicting toxic potencies and criteria thresholds of more metals or metalloids. Copyright © 2014 Elsevier Ltd. All rights reserved.

  1. LOBSTER - New Space X-Ray telescopes

    International Nuclear Information System (INIS)

    Hudec, R.; Pina, L.; Simon, V.; Sveda, L.; Inneman, A.; Semencova, V.; Skulinova, M.

    2007-01-01

    We discuss the technological and scientific aspects of fully innovative very wide-field X-ray telescopes with high sensitivity. The prototypes of Lobster telescopes designed, developed and tested are very promising, allowing the proposals for space projects with very wide-field Lobster Eye X-ray optics to be considered for the first time. The novel telescopes will monitor the sky with unprecedented sensitivity and angular resolution of order of 1 arcmin. They are expected to contribute essentially to study of various astrophysical objects such as AGN, SNe, Gamma-ray bursts (GRBs), X-ray flashes (XRFs), galactic binary sources, stars, CVs, X-ray novae, various transient sources, etc. For example, the Lobster optics based X-ray All Sky Monitor is capable to detect around 20 GRBs and 8 XRFs yearly and this will surely significantly contribute to the related science

  2. Fluorescence detection of white-beam X-ray absorption anisotropy: towards element-sensitive projections of local atomic structure

    Science.gov (United States)

    Korecki, P.; Tolkiehn, M.; Dąbrowski, K. M.; Novikov, D. V.

    2011-01-01

    Projections of the atomic structure around Nb atoms in a LiNbO3 single crystal were obtained from a white-beam X-ray absorption anisotropy (XAA) pattern detected using Nb K fluorescence. This kind of anisotropy results from the interference of X-rays inside a sample and, owing to the short coherence length of a white beam, is visible only at small angles around interatomic directions. Consequently, the main features of the recorded XAA corresponded to distorted real-space projections of dense-packed atomic planes and atomic rows. A quantitative analysis of XAA was carried out using a wavelet transform and allowed well resolved projections of Nb atoms to be obtained up to distances of 10 Å. The signal of nearest O atoms was detected indirectly by a comparison with model calculations. The measurement of white-beam XAA using characteristic radiation indicates the possibility of obtaining element-sensitive projections of the local atomic structure in more complex samples. PMID:21997909

  3. Cytological characterization of Chinese hamster ovary X-ray-sensitive mutant cells xrs 5 and xrs 6. 1

    International Nuclear Information System (INIS)

    Darroudi, F.

    1987-01-01

    The authors have determined the rate of progression of the cell cycle of irradiated cells in the presence of caffeine as well as the potentiating effect of caffeine on the frequency of chromosomal aberrations after X-irradiation. The characteristics for survival, frequency of chromosomal alterations and cell cycle progression in the presence or absence of 3-aminobenzamide (3AB) and caffeine of X-irradiated xrs 5, xrs 6 and parental wild-type CHO-K1 cells are discussed and compared to other X-ray-sensitive cells such as cells from ataxia telangiectasia patients. (Auth.)

  4. Projection-type X-ray microscope based on a spherical compound refractive X-ray lens

    OpenAIRE

    Dudchik, Yu. I.; Gary, C. K.; Park, H.; Pantell, R. H.; Piestrup, M. A.

    2007-01-01

    New projection- type X-ray microscope with a compound refractive lens as the optical element is presented. The microscope consists of an X-ray source that is 1-2 mm in diameter, compound X-ray lens and X-ray camera that are placed in-line to satisfy the lens formula. The lens forms an image of the X-ray source at camera sensitive plate. An object is placed between the X-ray source and the lens as close as possible to the source, and the camera shows a shadow image of the object. Spatial resol...

  5. Objective CT criteria to determine the presence of abnormal basal enhancement in children with suspected tuberculous meningitis

    Energy Technology Data Exchange (ETDEWEB)

    Przybojewski, Stefan; Andronikou, Savvas [Stellenbosch University Medical School, Department of Radiology, P.O. Box 19063, Tygerberg (South Africa); Wilmshurst, Jo [Red Cross Children' s Hospital and School of Child and Adolescent Health, Department of Paediatric Neurology, Cape Town (South Africa)

    2006-07-15

    There are no widely accepted objective criteria to determine the presence of basal enhancement on CT in children with suspected tuberculous meningitis (TBM). To test nine recently described objective CT criteria for the presence of abnormal basal enhancement in children with suspected TBM against the definite diagnosis as determined by cerebrospinal fluid (CSF) culture. CT scans of patients with a clinical suspicion of TBM who had undergone lumbar puncture for CSF culture spanning a period of 4 years were reviewed for the presence of nine recently described criteria for the presence of abnormal basal enhancement. The radiologists were blinded to the final diagnosis based on CSF culture against which the criteria were tested. The criteria have been named: the 'Y-sign', 'linear enhancement', 'double lines', 'infundibular recess of the third', 'ill-defined edge', 'nodular enhancement', 'join the dots', 'contrast filling the cisterns', and 'asymmetry'. A total of 65 patients were included in the study, 34 with culture-proven TBM and 31 with other diagnoses. Four individual criteria had a specificity of 100%, but the sensitivities of these criteria ranged from 15% to 53% only. Three other criteria had specificities of 97% and sensitivities ranging from 62% to 82%. The presence of more than one criterion in the same patient showed a specificity of 97% and sensitivity of 91%. Very high specificity was demonstrated for all nine criteria, including 100% specificity for four individual criteria. Sensitivity was at best 82%, but improved to 91% when more than one criterion was present. These criteria need to be tested for inter- and intraobserver variability to prove their clinical usefulness. (orig.)

  6. Performance of a position sensitive Si(Li) x-ray detector dedicated to Compton polarimetry of stored and trapped highly-charged ions

    International Nuclear Information System (INIS)

    Weber, G; Braeuning, H; Hess, S; Maertin, R; Spillmann, U; Stoehlker, Th

    2010-01-01

    We report on a novel two-dimensional position sensitive Si(Li) detector dedicated to Compton polarimetry of x-ray radiation arising from highly-charged ions. The performance of the detector system was evaluated in ion-atom collision experiments at the ESR storage ringe at GSI, Darmstadt. Based on the data obtained, the polarimeter efficiency is estimated in this work.

  7. Study on TV X-ray system characteristics

    International Nuclear Information System (INIS)

    Semenov, A.P.; Volkov, A.V.

    1978-01-01

    The results are presented of comparative investigations into the main characteristics of TV X-ray systems (TXS) and X-ray radiography when X-raying of the 1Kh18N9T steel. The following characteristics are considered: the threshold contrast sensitivity, the sensitivity to revealing standard defects, and the dose rate of X-radiation at the input of the X-ray converter. Practical recommendations are given on the use of TXS in flaw detection of various materials. It is remarked to use introscopes for testing of thick welded products articles, and X-ray vidicon systems for study of low-contrast images (in testing of welds made by point welding, and of thin-wall products)

  8. The relationship between cell killing, chromosome aberrations, spindle defects, and mitotic delay in mouse lymphoma cells of differential sensitivity to X-rays

    International Nuclear Information System (INIS)

    Scott, D.; Zampetti-Bosseler, F.

    1980-01-01

    A study has been made of the effects of x radiation on an ultrasensitive subline of L5178Y mouse lymphoma cells. It has been shown that at survival levels above about 20 per cent, chromosome structural aberrations which lead to bridges and fragments at anaphase are about four times more frequent than spindle defects. The results demonstrated the higher frequency of structural aberrations and spindle defects, and the greater mitotic delay in the X-ray-sensitive than in the X-ray-resistant cell line. A model is proposed which causally relates these end-points to cell killing and DNA repair. (author)

  9. Fabrics Protect Sensitive Skin from UV Rays

    Science.gov (United States)

    2009-01-01

    Late Johnson Space Center engineer Dr. Robert Dotts headed a team to develop cool suits for children suffering from life-threatening sun sensitivities. Dotts hoped to develop ultraviolet-blocking technology in a fabric that -- unlike in a bulky space suit -- could remain comfortable, light, and breathable in the sun and heat. The team worked with SPF 4 US LLC (SPF) of Madison, Wisconsin to design ultraviolet-blocking cool suits, which protect sun-sensitive patients and enable them to experience life outdoors safely. Using knowledge gained during the NASA collaboration, SPF created an entire line of ultraviolet-blocking apparel.

  10. Psychoneurometric operationalization of threat sensitivity: Relations with clinical symptom and physiological response criteria.

    Science.gov (United States)

    Yancey, James R; Venables, Noah C; Patrick, Christopher J

    2016-03-01

    The National Institute of Mental Health's Research Domain Criteria (RDoC) initiative calls for the incorporation of neurobiological approaches and findings into conceptions of mental health problems through a focus on biobehavioral constructs investigated across multiple domains of measurement (units of analysis). Although the constructs in the RDoC system are characterized in "process terms" (i.e., as functional concepts with brain and behavioral referents), these constructs can also be framed as dispositions (i.e., as dimensions of variation in biobehavioral functioning across individuals). Focusing on one key RDoC construct, acute threat or "fear," the current article illustrates a construct-oriented psychoneurometric strategy for operationalizing this construct in individual difference terms-as threat sensitivity (THT+). Utilizing data from 454 adult participants, we demonstrate empirically that (a) a scale measure of THT+ designed to tap general fear/fearlessness predicts effectively to relevant clinical problems (i.e., fear disorder symptoms), (b) this scale measure shows reliable associations with physiological indices of acute reactivity to aversive visual stimuli, and (c) a cross-domain factor reflecting the intersection of scale and physiological indicators of THT+ predicts effectively to both clinical and neurophysiological criterion measures. Results illustrate how the psychoneurometric approach can be used to create a dimensional index of a biobehavioral trait construct, in this case THT+, which can serve as a bridge between phenomena in domains of psychopathology and neurobiology. Implications and future directions are discussed with reference to the RDoC initiative and existing report-based conceptions of psychological traits. © 2016 Society for Psychophysiological Research.

  11. Soft x-ray Planetary Imager

    Data.gov (United States)

    National Aeronautics and Space Administration — The project is to prototype a soft X-ray Imager for planetary applications that has the sensitivity to observe solar system sources of soft  X-ray emission. A strong...

  12. Are Classification Criteria for IgG4-RD Now Possible? The Concept of IgG4-Related Disease and Proposal of Comprehensive Diagnostic Criteria in Japan

    Directory of Open Access Journals (Sweden)

    Kazuichi Okazaki

    2012-01-01

    Full Text Available Recent studies suggest simultaneous or metachronous lesions in multiorgans characterized by elevated serum levels of IgG4 and abundant infiltration of IgG4-positive plasma cells with various degrees of fibrosis. Two Japanese research committees for IgG4-RD, one from fibrosclerosis (Okazaki team and the other from lymph proliferation (Umehara team supported by the “Research Program for Intractable Disease” of the Ministry of Health, Labor, and Welfare of Japan, have agreed with the unified nomenclature as “IgG4-RD” and proposed the comprehensive diagnostic criteria (CDC for IgG4-RD. Validation of the CDC demonstrated satisfactory sensitivity for the practical use of general physicians and nonspecialists but low sensitivity in the organs to be difficult in taking biopsy specimens such as type1 autoimmune pancreatitis (IgG4-related AIP, compared with IgG4-related sialadenitis/dacryoadenitis (Mikulicz's disease and IgG4-related kidney disease. Although the diagnostic criteria covering all IgG4-RD are hard to be established, combination with the CDC and organ-specific diagnostic criteria should improve sensitivity.

  13. Imaging plate, a new type of x-ray area detector

    International Nuclear Information System (INIS)

    Kamiya, Nobuo; Amemiya, Yoshiyuki; Miyahara, Junji.

    1986-01-01

    In respective fields of X-ray crystallography, for the purpose of the efficient collection of reciprocal space information, two-dimensional X-ray detectors such as multiwire proportional chambers and X-ray television sets have been used together with conventional X-ray films. X-ray films are characterized by uniform sensitivity and high positional resolution over a wide area, but the sensitivity is low, and the range of action and the linearity of the sensitivity is problematic. They require the development process, accordingly lack promptitude. The MWPCs and X-ray television sets are superior in the sensitivity, its linearity, the range of action and promptitude, but interior in the uniformity and resolution to the films. Imaging plate is a new X-ray area detector developed by Fuji Photo Film Co., Ltd., for digital X-ray medical image diagnosis. This detector is superior in all the above mentioned performances, and it seems very useful also for X-ray crystallography. In this paper, the system composed of an imaging plate and its reader is described, and the basic performance as an X-ray area detector and the results of having recorded the diffraction images of protein crystals as the example of applying it to X-ray crystallography are reported. The imaging plate is that the crystalline fluorescent powder of BaFBr doped with Eu 2+ ions is applied on plastic films. (Kako, I.)

  14. Sensitization by wortmannin of heat- or X-ray induced cell death in cultured Chinese hamster V79 cells

    International Nuclear Information System (INIS)

    Tomita, Masanori; Suzuki, Norio; Matsumoto, Yoshihisa; Hirano, Kazuya; Umeda, Noriko; Sakai, Kazuo

    2000-01-01

    Here we found that wortmannin sensitized Chinese hamster V79 cells to hyperthermic treatment at 44.0 deg C as determined either by colony formation assay or by dye exclusion assay. Wortmannin enhanced heat-induced cell death accompanying cleavage of poly (ADP-ribose) polymerases (PARP). Additionally, the induction of heat shock protein HSP70 was suppressed and delayed in wortmannin-treated cells. Heat sensitizing effect of wortmannin was obvious at more than 5 or 10 μM of final concentrations, while radiosensitization was apparent at 5 μM. Requirement for high concentration of wortmannin, i.e., order of μM, suggests a possible role of certain protein kinases, such as DNA-PK and/or ATM among PI3-kinase family. The sensitization was minimal when wortmannin was added at the end of heat treatment. This was similar to the case of X-ray. Since heat-induced cell death and PARP cleavage preceded HSP70 induction phenomenon, the sensitization to the hyperthermic treatment was considered mainly caused by enhanced apoptotic cell death rather than secondary to suppression or delay by wortmannin of HSP70 induction. Further, in the present system radiosensitization by wortmannin was also at least partly mediated through enhancement of apoptotic cell death. (author)

  15. Antioxidant and sensitizer effect on the stability of natural rubber latex vulcanized by gamma rays

    International Nuclear Information System (INIS)

    Canavel, V.

    1993-01-01

    The natural rubber latex was vulcanized by gamma rays and electrons beam, in the presence and absence of sensitizer at room temperature. The sensitizers were the following; n-butyl acrylate (n-BA) / t-butyl hydroperoxide (t-B H) / KOH, C Cl 4 / potassium laurate and n-BA / KOH. The studied antioxidants, Irganox 1520, Vulcanox SP and Vulcanox BKF, were added to the latex after irradiation. Among the studied antioxidants in function of tensile strength (TS) after the aging of rubber plates, the Irganox was the best efficient on the gamma vulcanization in the presence of n-BA/t-B H/KOH, because only 0,20 p hr is enough to obtain the greatest increase of TS, that was 34%, 12 MPa to 16 MPa. The formulating method of latex with the sensitizer constituted the 3,0 p hr of n-BA/ 0,1 p hr of t-B H and 0,2 p hr of KOH, was evaluated respecting the TS of rubber plates. The electrons beam vulcanization produces the greatest reversible perturbance in the colloidal stability of latex after irradiation caused by radiolytic species absorption that promotes the increase of particle size. The antioxidant also contributes to reversible destabilization of gamma irradiated latex, because it is also adsorbed by particles surface. The relation between the latex viscosity and the TS of respective rubber plates is reverse, showing the latex stability affects the quality of rubber goods. (author)

  16. Design Optimization Method for Composite Components Based on Moment Reliability-Sensitivity Criteria

    Science.gov (United States)

    Sun, Zhigang; Wang, Changxi; Niu, Xuming; Song, Yingdong

    2017-08-01

    In this paper, a Reliability-Sensitivity Based Design Optimization (RSBDO) methodology for the design of the ceramic matrix composites (CMCs) components has been proposed. A practical and efficient method for reliability analysis and sensitivity analysis of complex components with arbitrary distribution parameters are investigated by using the perturbation method, the respond surface method, the Edgeworth series and the sensitivity analysis approach. The RSBDO methodology is then established by incorporating sensitivity calculation model into RBDO methodology. Finally, the proposed RSBDO methodology is applied to the design of the CMCs components. By comparing with Monte Carlo simulation, the numerical results demonstrate that the proposed methodology provides an accurate, convergent and computationally efficient method for reliability-analysis based finite element modeling engineering practice.

  17. Development of confocal micro X-ray fluorescence instrument using two X-ray beams

    International Nuclear Information System (INIS)

    Tsuji, Kouichi; Nakano, Kazuhiko; Ding Xunliang

    2007-01-01

    A new confocal micro X-ray fluorescence instrument was developed. This instrument has two independent micro X-ray tubes with Mo targets. A full polycapillary X-ray lens was attached to each X-ray tube. Another half polycapillary lens was attached to a silicon drift X-ray detector (SDD). The focal spots of the three lenses were adjusted to a common position. The effects of the excitation of two X-ray beams were investigated. The instrument enabled highly sensitive three-dimensional X-ray fluorescence analysis. We confirmed that the X-ray fluorescence intensity from the sample increased by applying the two independent X-ray tubes in confocal configuration. Elemental depth profiling of black wheat was demonstrated with the result that each element in the surface coat of a wheat grain showed unique distribution

  18. Operators work reliability current control based on the psychological and physiological criteria

    International Nuclear Information System (INIS)

    Karpenko, A.V.; Burov, A.Yu.; Grigorus', A.G.; Kal'nish, V.V.; Kapshuk, A.P.; Grigor'yants, T.N.; Bobko, N.A.

    1984-01-01

    A possibility of developing highly sensitive criteria for assessment of mental working ability at the expense of profound automated analysis of available psychological and physiological criteria is disclosed; it is a precondition for developing operator is woAking ability control system not requiring additional personnel for its operation

  19. Use of multi-criteria decision analysis to identify potentially dangerous glacial lakes.

    Science.gov (United States)

    Kougkoulos, Ioannis; Cook, Simon J; Jomelli, Vincent; Clarke, Leon; Symeonakis, Elias; Dortch, Jason M; Edwards, Laura A; Merad, Myriam

    2018-04-15

    Glacial Lake Outburst Floods (GLOFs) represent a significant threat in deglaciating environments, necessitating the development of GLOF hazard and risk assessment procedures. Here, we outline a Multi-Criteria Decision Analysis (MCDA) approach that can be used to rapidly identify potentially dangerous lakes in regions without existing tailored GLOF risk assessments, where a range of glacial lake types exist, and where field data are sparse or non-existent. Our MCDA model (1) is desk-based and uses freely and widely available data inputs and software, and (2) allows the relative risk posed by a range of glacial lake types to be assessed simultaneously within any region. A review of the factors that influence GLOF risk, combined with the strict rules of criteria selection inherent to MCDA, has allowed us to identify 13 exhaustive, non-redundant, and consistent risk criteria. We use our MCDA model to assess the risk of 16 extant glacial lakes and 6 lakes that have already generated GLOFs, and found that our results agree well with previous studies. For the first time in GLOF risk assessment, we employed sensitivity analyses to test the strength of our model results and assumptions, and to identify lakes that are sensitive to the criteria and risk thresholds used. A key benefit of the MCDA method is that sensitivity analyses are readily undertaken. Overall, these sensitivity analyses lend support to our model, although we suggest that further work is required to determine the relative importance of assessment criteria, and the thresholds that determine the level of risk for each criterion. As a case study, the tested method was then applied to 25 potentially dangerous lakes in the Bolivian Andes, where GLOF risk is poorly understood; 3 lakes are found to pose 'medium' or 'high' risk, and require further detailed investigation. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Effect of refraction index and thickness of the light guide in the position-sensitive gamma-ray detector using compact PS-PMTs

    International Nuclear Information System (INIS)

    Inoue, K.; Saito, H.; Nagashima, Y.; Hyodo, T.; Nagai, Y.; Muramatsu, S.; Nagai, S.

    2000-01-01

    We constructed a position-sensitive gamma-ray detector consisting of an array of BGO scintillators, a light guide and compact PS-PMTs. The effects of refractive index and thickness of the light guide of a glass plate on the detector performance were investigated. A light guide with higher refractive index and smaller thickness is found better for a good spatial resolution.

  1. AGILE: A gamma-ray mission

    International Nuclear Information System (INIS)

    Tavani, M.; Caraveo, P.; Mereghetti, S.; Perotti, F.; Vercellone, S.; Barbiellini, G.; Budini, G.; Longo, F.; Prest, M.; Vallazza, E.; Cocco, V.; Morselli, A.; Picozza, P.; Pittori, C.; Costa, E.; Feroci, M.; Lapshov, I.; Morelli, E.; Rubini, A.; Soffitta, P.

    2000-01-01

    AGILE is an innovative, cost-effective gamma-ray mission selected by the Italian Space Agency for a Program of Small Scientific Missions. The AGILE gamma-ray imaging detector (GRID, made of a Silicon tracker and CsI Mini-Calorimeter) is designed to detect and image photons in the 30 MeV-50 GeV energy band with good sensitivity and very large field of view (FOV ∼3 sr). The X-ray detector, Super-AGILE, sensitive in the 10-40 keV band and integrated on top of the GRID gamma-ray tracker will provide imaging (1-3 arcmin) and moderate spectroscopy. For selected sky areas, AGILE might achieve a flux sensitivity (above 100 MeV) better than 5x10 -8 ph cm 2 s -1 at the completion of its scientific program. AGILE will operate as an Observatory open to the international community and is planned to be operational during the year 2002 for a nominal 2-year mission. It will be an ideal 'bridge' between EGRET and GLAST, and the only mission entirely dedicated to high-energy astrophysics above 30 MeV during that period

  2. Gamma ray astronomy

    International Nuclear Information System (INIS)

    Fichtel, C.E.

    1975-01-01

    The first certain detection of celestial high energy gamma rays came from a satellite experiment flown on the third Orbiting Solar Observatory (OSO-111). A Gamma ray spark chamber telescope with substantively greater sensitivity and angular resolution (a few degrees) flown on the second Small Astronomy Satellite (SAS-II) has now provided a better picture of the gamma ray sky, and particularly the galactic plane and pulsars. This paper will summarize the present picture of gamma ray astronomy as it has developed at this conference from measurements made with experiments carried out on balloons, those remaining on the ground, and ones flown on satellites. (orig.) [de

  3. Sensitivity Analysis of X-ray Spectra from Scanning Electron Microscopes

    Energy Technology Data Exchange (ETDEWEB)

    Miller, Thomas Martin [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Patton, Bruce W. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Weber, Charles F. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Bekar, Kursat B. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2014-10-01

    The primary goal of this project is to evaluate x-ray spectra generated within a scanning electron microscope (SEM) to determine elemental composition of small samples. This will be accomplished by performing Monte Carlo simulations of the electron and photon interactions in the sample and in the x-ray detector. The elemental inventories will be determined by an inverse process that progressively reduces the difference between the measured and simulated x-ray spectra by iteratively adjusting composition and geometric variables in the computational model. The intended benefit of this work will be to develop a method to perform quantitative analysis on substandard samples (heterogeneous phases, rough surfaces, small sizes, etc.) without involving standard elemental samples or empirical matrix corrections (i.e., true standardless quantitative analysis).

  4. Soft X-ray spectrographs for solar observations

    Science.gov (United States)

    Bruner, M. E.

    1988-01-01

    Recent advances in soft X-ray spectrometery are reviewed, with emphasis on techniques for studying the windowless region from roughly 1-100 A. Recent technological developments considered include multilayer mirrors, large-format CCD detectors which are sensitive to X-rays, position-sensitive photon counting detectors, new kinds of X-ray films, and optical systems based on gratings with nonuniform ruling spacings. Improvements in the extent and accuracy of the atomic physics data sets on which the analysis of spectroscopic observatons depend are also discussed.

  5. Alteration of sensitivity of intratumor quiescent and total cells to γ-rays following thermal neutron irradiation with or without 10B-compound

    International Nuclear Information System (INIS)

    Masunaga, Shin-ichiro; Ono, Koji; Suzuki, Minoru; Sakurai, Yoshinori; Kobayashi, Tooru; Takagaki, Masao; Kinashi, Yuko; Akaboshi, Mitsuhiko

    2000-01-01

    Purpose: Changes in the sensitivity of intratumor quiescent (Q) and total cells to γ-rays following thermal neutron irradiation with or without 10 B-compound were examined. Methods and Materials: 5-Bromo-2'-deoxyuridine (BrdU) was injected to SCC VII tumor-bearing mice intraperitoneally 10 times to label all the proliferating (P) tumor cells. As priming irradiation, thermal neutrons alone or thermal neutrons with 10 B-labeled sodium borocaptate (BSH) or dl-p-boronophenylalanine (BPA) were administered. The tumor-bearing mice then received a series of γ-ray radiation doses, 0 through 24 h after the priming irradiation. During this period, no BrdU was administered. Immediately after the second irradiation, the tumors were excised, minced, and trypsinized. Following incubation of tumor cells with cytokinesis blocker, the micronucleus (MN) frequency in cells without BrdU labeling (= Q cells at the time of priming irradiation) was determined using immunofluorescence staining for BrdU. The MN frequency in the total (P + Q) tumor cells was determined from the tumors that were not pretreated with BrdU before the priming irradiation. To determine the BrdU-labeled cell ratios in the tumors at the time of the second irradiation, each group also included mice that were continuously administered BrdU until just before the second irradiation using mini-osmotic pumps which had been implanted subcutaneously 5 days before the priming irradiation. Results: In total cells, during the interval between the two irradiations, the tumor sensitivity to γ-rays relative to that immediately after priming irradiation decreased with the priming irradiation ranking in the following order: thermal neutrons only > thermal neutrons with BSH > thermal neutrons with BPA. In contrast, in Q cells, during that time the sensitivity increased in the following order: thermal neutrons only 10 B-compound, especially BPA, in thermal neutron irradiation causes the recruitment from the Q to P population

  6. Operation of an InGrid based X-ray detector at the CAST experiment

    Science.gov (United States)

    Krieger, Christoph; Desch, Klaus; Kaminski, Jochen; Lupberger, Michael

    2018-02-01

    The CERN Axion Solar Telescope (CAST) is searching for axions and other particles which could be candidates for DarkMatter and even Dark Energy. These particles could be produced in the Sun and detected by a conversion into soft X-ray photons inside a strong magnetic field. In order to increase the sensitivity for physics beyond the Standard Model, detectors with a threshold below 1 keV as well as efficient background rejection methods are required to compensate for low energies and weak couplings resulting in very low detection rates. Those criteria are fulfilled by a detector utilizing the combination of a pixelized readout chip with an integrated Micromegas stage. These InGrid (Integrated Grid) devices can be build by photolithographic postprocessing techniques, resulting in a close to perfect match of grid and pixels facilitating the detection of single electrons on the chip surface. The high spatial resolution allows for energy determination by simple electron counting as well as for an event-shape based analysis as background rejection method. Tests at an X-ray generator revealed the energy threshold of an InGrid based X-ray detector to be well below the carbon Kα line at 277 eV. After the successful demonstration of the detectors key features, the detector was mounted at one of CAST's four detector stations behind an X-ray telescope in 2014. After several months of successful operation without any detector related interruptions, the InGrid based X-ray detector continues data taking at CAST in 2015. During operation at the experiment, background rates in the order of 10-5 keV-1 cm-2 s-1 have been achieved by application of a likelihood based method discriminating the non-photon background originating mostly from cosmic rays. For continued operation in 2016, an upgraded InGrid based detector is to be installed among other improvements including decoupling and sampling of the signal induced on the grid as well as a veto scintillator to further lower the

  7. Soft x-ray streak cameras

    International Nuclear Information System (INIS)

    Stradling, G.L.

    1988-01-01

    This paper is a discussion of the development and of the current state of the art in picosecond soft x-ray streak camera technology. Accomplishments from a number of institutions are discussed. X-ray streak cameras vary from standard visible streak camera designs in the use of an x-ray transmitting window and an x-ray sensitive photocathode. The spectral sensitivity range of these instruments includes portions of the near UV and extends from the subkilovolt x- ray region to several tens of kilovolts. Attendant challenges encountered in the design and use of x-ray streak cameras include the accommodation of high-voltage and vacuum requirements, as well as manipulation of a photocathode structure which is often fragile. The x-ray transmitting window is generally too fragile to withstand atmospheric pressure, necessitating active vacuum pumping and a vacuum line of sight to the x-ray signal source. Because of the difficulty of manipulating x-ray beams with conventional optics, as is done with visible light, the size of the photocathode sensing area, access to the front of the tube, the ability to insert the streak tube into a vacuum chamber and the capability to trigger the sweep with very short internal delay times are issues uniquely relevant to x-ray streak camera use. The physics of electron imaging may place more stringent limitations on the temporal and spatial resolution obtainable with x-ray photocathodes than with the visible counterpart. Other issues which are common to the entire streak camera community also concern the x-ray streak camera users and manufacturers

  8. A Prospective Study of the Concordance of DSM-IV and DSM-5 Diagnostic Criteria for Autism Spectrum Disorder.

    Science.gov (United States)

    Mazurek, Micah O; Lu, Frances; Symecko, Heather; Butter, Eric; Bing, Nicole M; Hundley, Rachel J; Poulsen, Marie; Kanne, Stephen M; Macklin, Eric A; Handen, Benjamin L

    2017-09-01

    The transition from DSM-IV to DSM-5 criteria for autism spectrum disorder (ASD) sparked considerable concern about the potential implications of these changes. This study was designed to address limitations of prior studies by prospectively examining the concordance of DSM-IV and final DSM-5 criteria on a consecutive sample of 439 children referred for autism diagnostic evaluations. Concordance and discordance were assessed using a consistent diagnostic battery. DSM-5 criteria demonstrated excellent overall specificity and good sensitivity relative to DSM-IV criteria. Sensitivity and specificity were strongest for children meeting DSM-IV criteria for autistic disorder, but poor for those meeting criteria for Asperger's disorder and pervasive developmental disorder. Higher IQ, older age, female sex, and less pronounced ASD symptoms were associated with greater discordance.

  9. Application of the McDonald MRI criteria in multiple sclerosis.

    Science.gov (United States)

    Chan, Ling Ling; Sitoh, Yih Yian; Chong, June; See, Siew Ju; Umapathi, Thirugnanam N; Lim, Shih Hui; Ong, Benjamin

    2007-08-01

    The aim of this study was to assess the sensitivity of McDonald's magnetic resonance imaging (MRI) criteria for the diagnosis of multiple sclerosis (MS) in a group of Asian patients diagnosed with clinically definite MS, based on lesion characterisation on MRI scans. Forty-nine patients from 3 major neurological institutions were classified as having Asian- or Western-type MS based on clinical assessment. Each MRI scan was reviewed by 2 neuroradiologists for the presence and characteristics of brain and spinal lesions. The McDonald's MRI criteria were then applied and its sensitivity evaluated. Nine patients were excluded, leaving 34 females and 6 males who were dominantly Chinese (90%), with a mean age of 36.2 years. The MRI brain and spinal findings were detailed and tabulated. Statistically significant differences (P McDonald's MRI criteria were found between our Asian- and Western-type MS patients. The diagnostic yield of McDonald's MRI criteria increased by 20% when we substituted a cord for a brain lesion, and applied the substitution for enhancing cord lesions as well. The diagnosis is more likely to be made when using McDonald MRI criteria based on brain findings, in a patient who presents clinically with Western-type MS. The provision for substitution of "one brain for a spinal lesion" is helpful in Asian-type MS, where there is preponderance of spinal lesion load. Our findings suggest that minor modifications in the interpretation of McDonald's MRI criteria have significant impact on the diagnosis in patients clinically presenting as Asian-type MS, with potential bearing on their subsequent management.

  10. Sterilization of Bacillus spores by converted X-rays

    International Nuclear Information System (INIS)

    Ito, Hitoshi; Ohki, Yumi; Watanabe, Yuhei; Sunaga, Hiromi; Ishigaki, Isao

    1991-01-01

    Relative sensitivities of endospores of Bacillus pumilus E601, B. subtilis IAM1069, B. megaterium S31 and B. brevis S5 to gamma-rays, converted X-rays (Bremsstrahlung), and electron beams were examined in order to estimate the conditions in which converted X-rays kill Bacillus spores. The radiation sensitivities to gamma-rays, X-rays and electron beams of each strain dried on glass fiber filter without additives were found to be almost equivalent, and D 10 values were obtained as follows: 1.5-1.6 kGy for B. pumilus, 1.4-1.5 kGy for B. subtilis, 1.9-2.0 kGy for B. megaterium, and 1.6-2.0 kGy for B. brevis. The radiation sensitivities of endospores of each strain to electron beams were slightly lower than those to gamma-rays in the dry condition with additives of 2% peptone + 1% glycerin on glass fiber filter. The increase of radiation resistance in the presence of additives was also observed with X-rays, and it was on an intermediate level between those with gamma-rays and electron beams. In the dry condition using cellulose filter paper, only the radiation resistances of B. megaterium and B. brevis in the presence of additives were increased. (author)

  11. A sensitive and quantitative biosensing method for the determination of γ-ray emitting radionuclides in surface water

    International Nuclear Information System (INIS)

    Wolterbeek, H.Th.; Meer, A.J.G.M. van der

    1996-01-01

    A quantitative and sensitive biosensing method has been developed for the determination of γ-ray emitting radionuclides in surface water. The method is based on the concept that at equilibrium the specific radioactivity in the biosensor is equal to the specific radioactivity in water. The method consists of the measurement of both the radionuclide and the element in the biosensor and the determination of the element level in water. This three-way analysis eliminates problems such as unpredictable biosensor behaviour, effects of water elemental composition or further abiotic parameters: what remains is the generally high enrichment (bioaccumulation factor BCF) of elements and radionuclides in the biosensor material. Measurements were performed with floating water plants (Azolla filiculoides Lamk., Spirodela polyrhiza/Lemna sp.) and the fully submerged water plant Ceratophyllum demersum L., which were sampled from ditch water. Concentrations of elements and radionuclides were determined in both water and biosensor plants, using Neutron Activation Analysis (NAA), ICP-MS, and γ-ray spectrometry, respectively. For the latter, both 1 litre samples (Marinelli-geometry) and 1 cm 3 samples (well-type detectors) were applied in measurements. (author)

  12. Automated processing of X-ray images in medicine

    International Nuclear Information System (INIS)

    Babij, Ya.S.; B'yalyuk, Ya.O.; Yanovich, I.A.; Lysenko, A.V.

    1991-01-01

    Theoretical and practical achievements in application of computing technology means for processing of X-ray images in medicine were generalized. The scheme of the main directions and tasks of processing of X-ray images was given and analyzed. The principal problems appeared in automated processing of X-ray images were distinguished. It is shown that for interpretation of X-ray images it is expedient to introduce a notion of relative operating characteristic (ROC) of a roentgenologist. Every point on ROC curve determines the individual criteria of roentgenologist to put a positive diagnosis for definite situation

  13. Performance of the 2012 Systemic Lupus International Collaborating Clinics classification criteria versus the 1997 American College of Rheumatology classification criteria in adult and juvenile systemic lupus erythematosus. A systematic review and meta-analysis.

    Science.gov (United States)

    Hartman, Esther A R; van Royen-Kerkhof, Annet; Jacobs, Johannes W G; Welsing, Paco M J; Fritsch-Stork, Ruth D E

    2018-03-01

    To evaluate the performance in classifying systemic lupus erythematosus by the 2012 Systemic Lupus International Collaborating Clinics criteria (SLICC'12), versus the revised American College of Rheumatology criteria from 1997 (ACR'97) in adult and juvenile SLE patients. A systematic literature search was conducted in PubMed and Embase for studies comparing SLICC'12 and ACR'97 with clinical diagnosis. A meta-analysis was performed to estimate the sensitivity and specificity of SLICC'12 and ACR'97. To assess classification earlier in the disease by either set, sensitivity and specificity were compared for patients with disease duration <5years. Sensitivity and specificity of individual criteria items were also assessed. In adult SLE (nine studies: 5236 patients, 1313 controls), SLICC'12 has higher sensitivity (94.6% vs. 89.6%) and similar specificity (95.5% vs. 98.1%) compared to ACR'97. For juvenile SLE (four studies: 568 patients, 339 controls), SLICC'12 demonstrates higher sensitivity (99.9% vs. 84.3%) than ACR'97, but much lower specificity (82.0% vs. 94.1%). SLICC'12 classifies juvenile SLE patients earlier in disease course. Individual items contributing to diagnostic accuracy are low complement, anti-ds DNA and acute cutaneous lupus in SLICC'12, and the immunologic and hematologic disorder in ACR'97. Based on sensitivity and specificity SLICC'12 is best for adult SLE. Following the view that higher specificity, i.e. avoidance of false positives, is preferable, ACR'97 is best for juvenile SLE even if associated with lower sensitivity. Our results on the contribution of the individual items of SLICC'12 and ACR´97 may be of value in future efforts to update classification criteria. Copyright © 2018 The Authors. Published by Elsevier B.V. All rights reserved.

  14. Searches for hard X-ray gamma-ray burst afterglows with the BAT on Swift

    International Nuclear Information System (INIS)

    Krimm, Hans A.; Ozawa, Hideki; Weidenspointner, Georg; Barbier, Louis M.; Barthelmy, Scott D.; Gehrels, Neil; Parsons, Ann M.; Tueller, Jack; Eftekharzadeh, Ardeshir; Hullinger, Derek D.; Markwardt, Craig; Fenimore, Edward E.; Palmer, David M.

    2003-01-01

    The Burst Alert Telescope (BAT) on the Swift gamma ray burst mission will continue to observe the fields of all detected gamma-ray bursts for several days after the prompt emission has faded. Utilizing first event-by-event data, then one minute and later five minute survey accumulations, the BAT will be extremely sensitive to the hard X-ray afterglow known to be associated with many bursts. This data will cover the crucial transition of the afterglow from rapid variability to the smoothly decaying power law in time and will extend observations of the tails of individual bursts to longer time scales than have been achievable so far. Since Swift is sensitive to short duration GRBs, we will also be able to determine whether hard X-ray afterglows are associated with short GRBs. The BAT will provide high resolution spectra of burst afterglows, allowing us to study in detail the time evolution of GRB spectra

  15. Increased spontaneous mitotic segregation in MMS-sensitive mutants of Saccharomyces cerevisiae

    International Nuclear Information System (INIS)

    Prakash, S.; Prakash, L.

    1977-01-01

    Methyl methanesulfonate (MMS)-sensitive mutants of Saccharomyces cerevisiae belonging to four different complementation groups, when homozygous, increase the rate of spontaneous mitotic segregation to canavanine resistance from heterozygous sensitive (can/sup r//+) diploids by 13- to 170-fold. The mms8-1 mutant is MMS and x-ray sensitive and increases the rate of spontaneous mitotic segregation 170-fold. The mms9-1 and mms13-1 mutants are sensitive to x rays and uv, respectively, in addition to MMS, and increase the rate of spontaneous mitotic segregation by 13-fold and 85-fold, respectively. The mutant mms21-1 is sensitive to MMS, x rays and uv and increases the rate of spontaneous mitotic segregation 23-fold

  16. Evaluation of the 2010 McDonald multiple sclerosis criteria in children with a clinically isolated syndrome.

    Science.gov (United States)

    Kornek, Barbara; Schmitl, Beate; Vass, Karl; Zehetmayer, Sonja; Pritsch, Martin; Penzien, Johann; Karenfort, Michael; Blaschek, Astrid; Seidl, Rainer; Prayer, Daniela; Rostasy, Kevin

    2012-12-01

    Magnetic resonance imaging diagnostic criteria for paediatric multiple sclerosis have been established on the basis of brain imaging findings alone. The 2010 McDonald criteria for the diagnosis of multiple sclerosis, however, include spinal cord imaging for detection of lesion dissemination in space. The new criteria have been recommended in paediatric multiple sclerosis. (1) To evaluate the 2010 McDonald multiple sclerosis criteria in children with a clinically isolated syndrome and to compare them with recently proposed magnetic resonance criteria for children; (2) to assess whether the inclusion of spinal cord imaging provided additional value to the 2010 McDonald criteria. We performed a retrospective analysis of brain and spinal cord magnetic resonance imaging scans from 52 children with a clinically isolated syndrome. Sensitivity, specificity and accuracy of the magnetic resonance criteria were assessed. The 2010 McDonald dissemination in space criteria were more sensitive (85% versus 74%) but less specific (80% versus 100%) compared to the 2005 McDonald criteria. The Callen criteria were more accurate (89%) compared to the 2010 McDonald (85%), the 2005 McDonald criteria for dissemination in space (81%), the KIDMUS criteria (46%) and the Canadian Pediatric Demyelinating Disease Network criteria (76%). The 2010 McDonald criteria for dissemination in time were more accurate (93%) than the dissemination in space criteria (85%). Inclusion of the spinal cord did not increase the accuracy of the McDonald criteria.

  17. Skin fibroblasts from a D-deletion type retinoblastoma patient are abnormally X-ray sensitive

    International Nuclear Information System (INIS)

    Weichselbaum, R.R.; Nove, J.; Little, J.B.

    1977-01-01

    Retinoblastoma is a rare malignant eye tumour that appears either spontaneously or in genetically predisposed persons. The latter group is composed of persons who inherit the tumour with a dominant mode of transmission (the familial type) and those who have a deletion in the long arm of chromosome 13 referred to as the D-deletion type. When this deletion is present it is observed in many somatic cells and is often associated with structural defects. Survivors of the genetic forms of retinoblastoma have an increased risk of the development of cancers at other sites. A single genetic locus is unlikely to predispose many somatic cells to tumour formation unless a fundamental molecular defect, possibly related to DNA repair, is present. In order to investigate this hypothesis a study was made of the in vitro X-ray sensitivity of skin fibroblasts derived from three retinoblastoma patients, comprising a pair of twins with the familial type accompanied by no gross chromosome abnormalities, and a patient with the D-deletion type. It was found that fibroblasts derived from the D-deletion patient were significantly more radiosensitive than those from the other two patients. X-ray survival curves are shown. It is concluded that skin fibroblasts derived from a patient with the D-deletion variant of retinoblastoma are abnormally radiosensitive. Future investigations may indicate a specific defect in molecular repair of DNA that will explain the predisposition of these patients to the development of other tumours. (U.K.)

  18. Femtosecond X-ray magnetic circular dichroism absorption spectroscopy at an X-ray free electron laser

    Energy Technology Data Exchange (ETDEWEB)

    Higley, Daniel J., E-mail: dhigley@stanford.edu; Yuan, Edwin [SLAC National Accelerator Laboratory, 2575 Sand Hill Road, Menlo Park, California 94025 (United States); Department of Applied Physics, Stanford University, Stanford, California 94305 (United States); Hirsch, Konstantin; Dakovski, Georgi L.; Jal, Emmanuelle; Lutman, Alberto A.; Coslovich, Giacomo; Hart, Philip; Hoffmann, Matthias C.; Mitra, Ankush; Moeller, Stefan; Ohldag, Hendrik; Seaberg, Matthew; Stöhr, Joachim; Nuhn, Heinz-Dieter; Reid, Alex H.; Dürr, Hermann A.; Schlotter, William F. [SLAC National Accelerator Laboratory, 2575 Sand Hill Road, Menlo Park, California 94025 (United States); Liu, Tianmin; MacArthur, James P. [SLAC National Accelerator Laboratory, 2575 Sand Hill Road, Menlo Park, California 94025 (United States); Department of Physics, Stanford University, Stanford, California 94305 (United States); and others

    2016-03-15

    X-ray magnetic circular dichroism spectroscopy using an X-ray free electron laser is demonstrated with spectra over the Fe L{sub 3,2}-edges. The high brightness of the X-ray free electron laser combined with high accuracy detection of incident and transmitted X-rays enables ultrafast X-ray magnetic circular dichroism studies of unprecedented sensitivity. This new capability is applied to a study of all-optical magnetic switching dynamics of Fe and Gd magnetic sublattices in a GdFeCo thin film above its magnetization compensation temperature.

  19. Improving calibration and validation of cosmic-ray neutron sensors in the light of spatial sensitivity

    Directory of Open Access Journals (Sweden)

    M. Schrön

    2017-10-01

    Full Text Available In the last few years the method of cosmic-ray neutron sensing (CRNS has gained popularity among hydrologists, physicists, and land-surface modelers. The sensor provides continuous soil moisture data, averaged over several hectares and tens of decimeters in depth. However, the signal still may contain unidentified features of hydrological processes, and many calibration datasets are often required in order to find reliable relations between neutron intensity and water dynamics. Recent insights into environmental neutrons accurately described the spatial sensitivity of the sensor and thus allowed one to quantify the contribution of individual sample locations to the CRNS signal. Consequently, data points of calibration and validation datasets are suggested to be averaged using a more physically based weighting approach. In this work, a revised sensitivity function is used to calculate weighted averages of point data. The function is different from the simple exponential convention by the extraordinary sensitivity to the first few meters around the probe, and by dependencies on air pressure, air humidity, soil moisture, and vegetation. The approach is extensively tested at six distinct monitoring sites: two sites with multiple calibration datasets and four sites with continuous time series datasets. In all cases, the revised averaging method improved the performance of the CRNS products. The revised approach further helped to reveal hidden hydrological processes which otherwise remained unexplained in the data or were lost in the process of overcalibration. The presented weighting approach increases the overall accuracy of CRNS products and will have an impact on all their applications in agriculture, hydrology, and modeling.

  20. Improving calibration and validation of cosmic-ray neutron sensors in the light of spatial sensitivity

    Science.gov (United States)

    Schrön, Martin; Köhli, Markus; Scheiffele, Lena; Iwema, Joost; Bogena, Heye R.; Lv, Ling; Martini, Edoardo; Baroni, Gabriele; Rosolem, Rafael; Weimar, Jannis; Mai, Juliane; Cuntz, Matthias; Rebmann, Corinna; Oswald, Sascha E.; Dietrich, Peter; Schmidt, Ulrich; Zacharias, Steffen

    2017-10-01

    In the last few years the method of cosmic-ray neutron sensing (CRNS) has gained popularity among hydrologists, physicists, and land-surface modelers. The sensor provides continuous soil moisture data, averaged over several hectares and tens of decimeters in depth. However, the signal still may contain unidentified features of hydrological processes, and many calibration datasets are often required in order to find reliable relations between neutron intensity and water dynamics. Recent insights into environmental neutrons accurately described the spatial sensitivity of the sensor and thus allowed one to quantify the contribution of individual sample locations to the CRNS signal. Consequently, data points of calibration and validation datasets are suggested to be averaged using a more physically based weighting approach. In this work, a revised sensitivity function is used to calculate weighted averages of point data. The function is different from the simple exponential convention by the extraordinary sensitivity to the first few meters around the probe, and by dependencies on air pressure, air humidity, soil moisture, and vegetation. The approach is extensively tested at six distinct monitoring sites: two sites with multiple calibration datasets and four sites with continuous time series datasets. In all cases, the revised averaging method improved the performance of the CRNS products. The revised approach further helped to reveal hidden hydrological processes which otherwise remained unexplained in the data or were lost in the process of overcalibration. The presented weighting approach increases the overall accuracy of CRNS products and will have an impact on all their applications in agriculture, hydrology, and modeling.

  1. Sensitivity of human peripheral lymphocyte chromosomes to various X-ray doses and subsequent storage in Plexiglass or glass containers

    International Nuclear Information System (INIS)

    Ivanov, B.; Bulanova, M.; Geogieva, I.

    1979-01-01

    A study was performed to determine whether chromosomal aberrations produced in vitro by various X-ray doses in human lymphocytes were affected by post-irradiation storage of the blood in plastic or glass containers. Following X-ray doses of up to 400 R, the yields of cells with aberrations and the incidence of dicentrics, rings, interstitial deletions, symmetrical changes and chromosome fragments increased with dose. After storage of the irradiated lymphocytes in either Plexiglass or glass, the values for exchange aberrations, deletions and aberrant cells were compared. The only statistically significant difference was a slight increase in the percentage of aberrant cells stored in the plastic containers at the 400 R dose level. It was concluded that plastics appear to have a sensitizing effect on the genetic structure of the peripheral lymphocyte and thus the use of this material to store blood in biological dosimetry studies should be discouraged. (U.K.)

  2. Criteria for Performing Cranial Computed Tomography for Chinese Patients With Mild Traumatic Brain Injury: Canadian Computed Tomography Head Rule or New Orleans Criteria?

    Science.gov (United States)

    Yang, Xiao-Feng; Meng, Yuan-Yuan; Wen, Liang; Wang, Hao

    2017-09-01

    Computed tomography (CT) provides the primary diagnostic evidence for traumatic brain injury (TBI), but few positive traumatic findings are discovered in patients with mild TBI. In China, there are no existing criteria for selecting patients with mild TBI to undergo CT, and almost all of these patients undergo cranial CT in the emergency department. This retrospective study was performed to evaluate the necessity of cranial CT among patients with mild TBI, as well as the feasibility of 2 popular criteria (Canadian CT head rule [CCHR] and New Orleans Criteria [NOC]) in China. Patients with mild TBI who underwent cranial CT within 24 hours of the trauma were included in our institute. Two neurosurgeons reviewed the CT images independently to identify positive CT findings. The sensitivity and specificity of CCHR and NOC for positive CT findings related to TBI were analyzed. Finally, this study included 625 patients. Positive CT findings related to TBI were discovered in 13.12% (82/625) of these patients on cranial CT, and 6.88% (43/625) of them were admitted to the hospital for further management. Ultimately, 11 patients (1.76%, 11/625) underwent neurosurgery. In this study, the sensitivities of both the CCHR and NOC were 100%, but the specificity of CCHR was 43.36% and that of NOC was 33.12%. Based on our study, both CCHR and NOC have high sensitivity for the detection of positive CT findings related to head trauma in patients with mild TBI.

  3. TU-G-207-03: High Spatial Resolution and High Sensitivity X-Ray Fluorescence Imaging

    International Nuclear Information System (INIS)

    Xing, L.

    2015-01-01

    Last few years has witnessed the development of novel of X-ray imaging modalities, such as spectral CT, phase contrast CT, and X-ray acoustic/fluorescence/luminescence imaging. This symposium will present the recent advances of these emerging X-ray imaging modalities and update the attendees with knowledge in various related topics, including X-ray photon-counting detectors, X-ray physics underlying the emerging applications beyond the traditional X-ray imaging, image reconstruction for the novel modalities, characterization and evaluation of the systems, and their practical implications. In addition, the concept and practical aspects of X-ray activatable targeted nanoparticles for molecular X-ray imaging will be discussed in the context of X-ray fluorescence and luminescence CT. Learning Objectives: Present background knowledge of various emerging X-ray imaging techniques, such as spectral CT, phase contrast CT and X-ray fluorescence/luminescence CT. Discuss the practical need, technical aspects and current status of the emerging X-ray imaging modalities. Describe utility and future impact of the new generation of X-ray imaging applications

  4. MDS clinical diagnostic criteria for Parkinson's disease in China.

    Science.gov (United States)

    Li, Jun; Jin, Miao; Wang, Li; Qin, Bin; Wang, Kang

    2017-03-01

    The Movement Disorder Society Clinical Diagnostic Criteria for Parkinson's disease (MDS-PD Criteria) was introduced by the Movement Disorder Society in 2015 for research purposes. However, its use for clinical diagnosis of Parkinson disease still needs further revision. This study compares the UK-Criteria versus MDS-PD Criteria in the clinical diagnosis of Parkinson disease referred to the China-Japan Friendship Hospital of Beijing, China. To compare the MDS-PD Criteria with the UK-Criteria and discuss the feasibility of the clinical application of MDS-PD Criteria as a general guide to clinical diagnosis of PD in Chinese PD patients. 150 patients of neurology clinic of China-Japan Friendship Hospital of Beijing were recruited in our research. They were divided into three groups: UK-Criteria group, MDS-PD Criteria group and a combined group of UK and MDS-PD Criteria. Clinical history was collected while physical and auxiliary examinations were done by a trained neurologist according to the corresponding criteria. An interrater reliability analysis using the Kappa statistic claimed substantial agreement (κ = 0.626) between the MDS-PD Criteria and the UK-Criteria. The differences between the diagnostic results of these two criteria were statistically significant by paired Chi-square test (p = 0.000). It was found that levodopa-induced dyskinesia had a good positive predictive value, while early bulbar impairment and inspiratory dysfunction presented a negative predictive value. The MDS-PD Criteria emphasize the importance of non-motor symptoms, keeping the motor symptoms as the core for the clinical diagnosis of PD, and establish categories of diagnosis features and levels of certainty which are more complete and organized to be used and replicated by non specialized physicians to evaluated patients with Parkinsonism. The higher sensitivity of MDS-PD Criteria compared with UK-Criteria is worth being widely used in clinical work.

  5. Development of a high resolution, high sensitivity cylindrical crystal spectrometer for line shape diagnostics of x-rays emitted from hot plasmas. Progress report, August 1, 1977--July 31, 1978

    International Nuclear Information System (INIS)

    Taylor, P.O.; Schnopper, H.

    1978-05-01

    This report oulines progress towards development of a high resolution, high throughput, curved crystal spectrometer suitable for line shape diagnostics of x-rays emitted from hot plasmas. The instrument is designed to interface with the MIT Tokamak (Alcator) with the initial aim of studying the prominent MoL lines which occur in the x-ray spectrum. However, it will have the versatility to function over an energy range of at least 1.5 keV to 7 keV allowing determination of temperature, charge state and density distributions for important impurity ions. The spectrometer employs a large, cylindrically bent crystal which focuses the dispersed x-rays along the cylinder axis where they are recorded by a position sensitive proportional counter. Thus, a wide energy range of the spectrum can be recorded simultaneously and sensitively from a short duration plasma. Computer control of data acquisition and analysis will allow real-time diagnostics

  6. The effect of uncertainties in distance-based ranking methods for multi-criteria decision making

    Science.gov (United States)

    Jaini, Nor I.; Utyuzhnikov, Sergei V.

    2017-08-01

    Data in the multi-criteria decision making are often imprecise and changeable. Therefore, it is important to carry out sensitivity analysis test for the multi-criteria decision making problem. The paper aims to present a sensitivity analysis for some ranking techniques based on the distance measures in multi-criteria decision making. Two types of uncertainties are considered for the sensitivity analysis test. The first uncertainty is related to the input data, while the second uncertainty is towards the Decision Maker preferences (weights). The ranking techniques considered in this study are TOPSIS, the relative distance and trade-off ranking methods. TOPSIS and the relative distance method measure a distance from an alternative to the ideal and antiideal solutions. In turn, the trade-off ranking calculates a distance of an alternative to the extreme solutions and other alternatives. Several test cases are considered to study the performance of each ranking technique in both types of uncertainties.

  7. Improving radiochromic film's sensitivity by wrapping it with UV phosphor

    International Nuclear Information System (INIS)

    Geso, Moshi; Ackerly, Trevor; Patterson, William

    2004-01-01

    The main advantage of radiochromic-film dosimeters is the coupling of rapid full planar-acquisition, high-spatial resolution and dose linearity. Their main limitation, however, is their low radiation sensitivity. This precludes their application to measuring doses below a few Gy. Radiochromic films are sensitive to ultraviolet radiation. In this note the results of exposing radiochromic films to x rays through an UV imaging cassette, which converts and amplifies x rays to UV radiation, are presented. These results indicate a clear increase (around 50%) in radiochromic film's sensitivity to MV x rays (6, 10, and 18 MV) when exposed through the UV phosphor

  8. 3-D waveform tomography sensitivity kernels for anisotropic media

    KAUST Repository

    Djebbi, Ramzi

    2014-01-01

    The complications in anisotropic multi-parameter inversion lie in the trade-off between the different anisotropy parameters. We compute the tomographic waveform sensitivity kernels for a VTI acoustic medium perturbation as a tool to investigate this ambiguity between the different parameters. We use dynamic ray tracing to efficiently handle the expensive computational cost for 3-D anisotropic models. Ray tracing provides also the ray direction information necessary for conditioning the sensitivity kernels to handle anisotropy. The NMO velocity and η parameter kernels showed a maximum sensitivity for diving waves which results in a relevant choice of those parameters in wave equation tomography. The δ parameter kernel showed zero sensitivity; therefore it can serve as a secondary parameter to fit the amplitude in the acoustic anisotropic inversion. Considering the limited penetration depth of diving waves, migration velocity analysis based kernels are introduced to fix the depth ambiguity with reflections and compute sensitivity maps in the deeper parts of the model.

  9. SENSIT: a cross-section and design sensitivity and uncertainty analysis code

    International Nuclear Information System (INIS)

    Gerstl, S.A.W.

    1980-01-01

    SENSIT computes the sensitivity and uncertainty of a calculated integral response (such as a dose rate) due to input cross sections and their uncertainties. Sensitivity profiles are computed for neutron and gamma-ray reaction cross sections of standard multigroup cross section sets and for secondary energy distributions (SEDs) of multigroup scattering matrices. In the design sensitivity mode, SENSIT computes changes in an integral response due to design changes and gives the appropriate sensitivity coefficients. Cross section uncertainty analyses are performed for three types of input data uncertainties: cross-section covariance matrices for pairs of multigroup reaction cross sections, spectral shape uncertainty parameters for secondary energy distributions (integral SED uncertainties), and covariance matrices for energy-dependent response functions. For all three types of data uncertainties SENSIT computes the resulting variance and estimated standard deviation in an integral response of interest, on the basis of generalized perturbation theory. SENSIT attempts to be more comprehensive than earlier sensitivity analysis codes, such as SWANLAKE

  10. Determination of the metal distribution in tooth fillings in real teeth based on element sensitive X-ray tomography

    International Nuclear Information System (INIS)

    Masschaele, B.; Mondelaers, W.; Cauwels, P.; Jolie, J.; Baechler, S.; Materna, T.

    2000-01-01

    Since a couple of centuries people are using metal tooth-fillings in order to protect their teeth. In the beginning of the 19th century the amalgam or silver fillings were introduced for to first time. Nowadays, dentists mostly use amalgam. These fillings are a mixture of silver, tin and mercury. The mercury which is abundant, about 50%, is dangerous for any living organism. Mercury has a particular affinity for the brain tissue but is also accumulated in the liver, kidneys, lungs, gastrointestinal track and jawbone. Mercury Basely crosses the placenta and is gathered in the heart, pituitary gland and liver of the fetus. It is been proven that the mercury vaporises and enter enters the body via the lungs. Since a couple of years we apply the element sensitive X-ray tomography technique on heavy elements like uranium or lead. By scanning teeth using photons having two different energies, one just below and one just above the K-edge of the element under investigation, the tomography becomes element sensitive. The experiment has been done at the ESRF, beam line ID15A, with a very intense tunable monochromatic high energy X-ray beam. We made tomographies of different teeth with 20 μm image resolution. The slices were 20 μm apart. The results after reconstruction are three dimensional mercury maps which can tell us something about the possibility of mercury diffusion into the roots of the tooth. From there the mercury could enter the blood stream and end up in the organs. (author)

  11. ATWS sensitivity studies to support PSA success criteria

    International Nuclear Information System (INIS)

    Zheng Yaoyao; Xu Zhen; Ke Xiao

    2010-01-01

    The limiting anticipated transient without scram (ATWS) event is the heatup transient caused by a reduction of heat removal capability by the secondary side of the plant. In order to evaluate the AP1000 plant behavior following an ATWS, loss of normal feedwater ATWS event has been analyzed using the LOFTRAN code. Several sensitivity studies are also performed to address some key issues, such as steam dump capacity, core makeup tank (CMT) characteristic and boron coefficient, reactor coolant pumps (RCPs) availability, startup feedwater system (STS) availability and steam generator (SG) heat flux. The results of the analysis show that in order to mitigate the consequence of such an accident, the steam dump should be isolated and RCP should trip on CMT actuation signal. (authors)

  12. Cost and sensitivity of restricted active-space calculations of metal L-edge X-ray absorption spectra.

    Science.gov (United States)

    Pinjari, Rahul V; Delcey, Mickaël G; Guo, Meiyuan; Odelius, Michael; Lundberg, Marcus

    2016-02-15

    The restricted active-space (RAS) approach can accurately simulate metal L-edge X-ray absorption spectra of first-row transition metal complexes without the use of any fitting parameters. These characteristics provide a unique capability to identify unknown chemical species and to analyze their electronic structure. To find the best balance between cost and accuracy, the sensitivity of the simulated spectra with respect to the method variables has been tested for two models, [FeCl6 ](3-) and [Fe(CN)6 ](3-) . For these systems, the reference calculations give deviations, when compared with experiment, of ≤1 eV in peak positions, ≤30% for the relative intensity of major peaks, and ≤50% for minor peaks. When compared with these deviations, the simulated spectra are sensitive to the number of final states, the inclusion of dynamical correlation, and the ionization potential electron affinity shift, in addition to the selection of the active space. The spectra are less sensitive to the quality of the basis set and even a double-ζ basis gives reasonable results. The inclusion of dynamical correlation through second-order perturbation theory can be done efficiently using the state-specific formalism without correlating the core orbitals. Although these observations are not directly transferable to other systems, they can, together with a cost analysis, aid in the design of RAS models and help to extend the use of this powerful approach to a wider range of transition metal systems. © 2015 Wiley Periodicals, Inc.

  13. The influence of an extrapolation chamber over the low energy X-ray beam radiation field

    Energy Technology Data Exchange (ETDEWEB)

    Tanuri de F, M. T.; Da Silva, T. A., E-mail: mttf@cdtn.br [Centro de Desenvolvimento da Tecnologia Nuclear / CNEN, Av. Pte. Antonio Carlos 6627, 31270-901 Pampulha, Belo Horizonte, Minas Gerais (Brazil)

    2016-10-15

    The extrapolation chambers are detectors whose sensitive volume can be modified by changing the distance between the electrodes and has been widely used for beta particles primary measurement system. In this work, was performed a PTW 23392 extrapolation chamber Monte Carlo simulation, by mean the MCNPX code. Although the sensitive volume of an extrapolation chamber can be reduced to very small size, their packaging is large enough to modify the radiation field and change the absorbed dose measurements values. Experiments were performed to calculate correction factors for this purpose. The validation of the Monte Carlo model was done by comparing the spectra obtained with a CdTe detector according to the ISO 4037 criteria. Agreements smaller than 5% for half value layers, 10% for spectral resolution and 1% for mean energy, were found. It was verified that the correction factors are dependent of the X-ray beam quality. (Author)

  14. The influence of an extrapolation chamber over the low energy X-ray beam radiation field

    International Nuclear Information System (INIS)

    Tanuri de F, M. T.; Da Silva, T. A.

    2016-10-01

    The extrapolation chambers are detectors whose sensitive volume can be modified by changing the distance between the electrodes and has been widely used for beta particles primary measurement system. In this work, was performed a PTW 23392 extrapolation chamber Monte Carlo simulation, by mean the MCNPX code. Although the sensitive volume of an extrapolation chamber can be reduced to very small size, their packaging is large enough to modify the radiation field and change the absorbed dose measurements values. Experiments were performed to calculate correction factors for this purpose. The validation of the Monte Carlo model was done by comparing the spectra obtained with a CdTe detector according to the ISO 4037 criteria. Agreements smaller than 5% for half value layers, 10% for spectral resolution and 1% for mean energy, were found. It was verified that the correction factors are dependent of the X-ray beam quality. (Author)

  15. X-ray Optics Development at MSFC

    Science.gov (United States)

    Sharma, Dharma P.

    2017-01-01

    Development of high resolution focusing telescopes has led to a tremendous leap in sensitivity, revolutionizing observational X-ray astronomy. High sensitivity and high spatial resolution X-ray observations have been possible due to use of grazing incidence optics (paraboloid/hyperboloid) coupled with high spatial resolution and high efficiency detectors/imagers. The best X-ray telescope flown so far is mounted onboard Chandra observatory launched on July 23,1999. The telescope has a spatial resolution of 0.5 arc seconds with compatible imaging instruments in the energy range of 0.1 to 10 keV. The Chandra observatory has been responsible for a large number of discoveries and has provided X-ray insights on a large number of celestial objects including stars, supernova remnants, pulsars, magnetars, black holes, active galactic nuclei, galaxies, clusters and our own solar system.

  16. Water equivalence of NIPAM based polymer gel dosimeters with enhanced sensitivity for x-ray CT

    Science.gov (United States)

    Gorjiara, Tina; Hill, Robin; Bosi, Stephen; Kuncic, Zdenka; Baldock, Clive

    2013-10-01

    Two new formulations of N-isopropylacrylamide (NIPAM) based three dimensional (3D) gel dosimeters have recently been developed with improved sensitivity to x-ray CT readout, one without any co-solvent and the other one with isopropanol co-solvent. The water equivalence of the NIPAM gel dosimeters was investigated using different methods to calculate their radiological properties including: density, electron density, number of electrons per grams, effective atomic number, photon interaction probabilities, mass attenuation and energy absorption coefficients, electron collisional, radiative and total mass stopping powers and electron mass scattering power. Monte Carlo modelling was also used to compare the dose response of these gel dosimeters with water for kilovoltage and megavoltage x-ray beams and for megavoltage electron beams. We found that the density and electron density of the co-solvent free gel dosimeter are more water equivalent with less than a 2.6% difference compared to a 5.7% difference for the isopropanol gel dosimeter. Both the co-solvent free and isopropanol solvent gel dosimeters have lower effective atomic numbers than water, differing by 2.2% and 6.5%, respectively. As a result, their photoelectric absorption interaction probabilities are up to 6% and 19% different from water, respectively. Compton scattering and pair production interaction probabilities of NIPAM gel with isopropanol differ by up to 10% from water while for the co-solvent free gel, the differences are 3%. Mass attenuation and energy absorption coefficients of the co-solvent free gel dosimeter and the isopropanol gel dosimeter are up to 7% and 19% lower than water, respectively. Collisional and total mass stopping powers of both gel dosimeters differ by less than 2% from those of water. The dose response of the co-solvent free gel dosimeter is water equivalent (with x-ray beams over the energy range 180 keV-18 MV, both gel dosimeters have less than 2% discrepancy with water. For

  17. Evaluation of national health-care related infection criteria for epidemiological surveillance in neonatology.

    Science.gov (United States)

    Ferreira, Janita; Bouzada, Maria C F; Jesus, Lenize A de; Cortes, Maria da Conceição Werneck; Armond, Guilherme A; Clemente, Wanessa T; Anchieta, Lêni M; Romanelli, Roberta M C

    2014-01-01

    to assess the use of the Brazilian criteria for reporting of hospital-acquired infections (HAIs) in the neonatal unit and compare them with the criteria proposed by the National Healthcare Safety Network (NHSN). this was a cross-sectional study conducted from 2009 to 2011. It included neonates with HAI reporting by at least one of the criteria. Statistical analysis included calculation of incidence density of HAIs, distribution by weight, and by reporting criterion. Analysis of sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) for the national criteria was performed considering the NHSN as the gold standard, with agreement assessed by kappa. a total of 882 newborns were followed, and 330 had at least one infection notified by at least one of the criteria. A total of 522 HAIs were reported, regardless of the criteria. An incidence density of 27.28 infections per 1,000 patient-days was observed, and the main topographies were sepsis (58.3%), candidiasis (15.1%), and conjunctivitis (6.5%). A total of 489 (93.7%) were notified by both criteria, eight infections were notified only by the national criteria (six cases of necrotizing enterocolitis and two cases of conjunctivitis), and 25 cases of clinical sepsis were reported by NHSN criteria only. The sensitivity, specificity, PPV, and NPV were 95.1%, 98.6%, 98.4%, and 95.7%, respectively, for all topographies, and were 91.8%, 100%, 100%, and 96.3% for the analysis of sepsis. Kappa analysis showed an agreement of 96.9%. there was a high rate of agreement between the criteria. The use of the national criteria facilitates the reporting of sepsis in newborns, and can help to improve the specificity and PPV. Copyright © 2014 Sociedade Brasileira de Pediatria. Published by Elsevier Editora Ltda. All rights reserved.

  18. Evaluation of national health-care related infection criteria for epidemiological surveillance in neonatology

    Directory of Open Access Journals (Sweden)

    Janita Ferreira

    2014-07-01

    Full Text Available OBJECTIVE: to assess the use of the Brazilian criteria for reporting of hospital-acquired infections (HAIs in the neonatal unit and compare them with the criteria proposed by the National Healthcare Safety Network (NHSN. METHODS: this was a cross-sectional study conducted from 2009 to 2011. It included neonates with HAI reporting by at least one of the criteria. Statistical analysis included calculation of incidence density of HAIs, distribution by weight, and by reporting criterion. Analysis of sensitivity, specificity, positive predictive value (PPV, and negative predictive value (NPV for the national criteria was performed considering the NHSN as the gold standard, with agreement assessed by kappa. RESULTS: a total of 882 newborns were followed, and 330 had at least one infection notified by at least one of the criteria. A total of 522 HAIs were reported, regardless of the criteria. An incidence density of 27.28 infections per 1,000 patient-days was observed, and the main topographies were sepsis (58.3%, candidiasis (15.1%, and conjunctivitis (6.5%. A total of 489 (93.7% were notified by both criteria, eight infections were notified only by the national criteria (six cases of necrotizing enterocolitis and two cases of conjunctivitis, and 25 cases of clinical sepsis were reported by NHSN criteria only. The sensitivity, specificity, PPV, and NPV were 95.1%, 98.6%, 98.4%, and 95.7%, respectively, for all topographies, and were 91.8%, 100%, 100%, and 96.3% for the analysis of sepsis. Kappa analysis showed an agreement of 96.9%. CONCLUSION: there was a high rate of agreement between the criteria. The use of the national criteria facilitates the reporting of sepsis in newborns, and can help to improve the specificity and PPV.

  19. Analytical electron microscope based on scanning transmission electron microscope with wavelength dispersive x-ray spectroscopy to realize highly sensitive elemental imaging especially for light elements

    International Nuclear Information System (INIS)

    Koguchi, Masanari; Tsuneta, Ruriko; Anan, Yoshihiro; Nakamae, Koji

    2017-01-01

    An analytical electron microscope based on the scanning transmission electron microscope with wavelength dispersive x-ray spectroscopy (STEM-WDX) to realize highly sensitive elemental imaging especially for light elements has been developed. In this study, a large-solid-angle multi-capillary x-rays lens with a focal length of 5 mm, long-time data acquisition (e.g. longer than 26 h), and a drift-free system made it possible to visualize boron-dopant images in a Si substrate at a detection limit of 0.2 atomic percent. (paper)

  20. McDonald Criteria 2010 and 2005 Compared: Persistence of High Oligoclonal Band Prevalence Despite Almost Doubled Diagnostic Sensitivity

    Directory of Open Access Journals (Sweden)

    Philipp Schwenkenbecher

    2016-09-01

    Full Text Available The 2010 McDonald criteria were developed to allow a more rapid diagnosis of relapsing-remitting multiple sclerosis (MS by only one MRI of the brain. Although cerebrospinal fluid (CSF is not a mandatory part of the latest criteria, the evidence of an intrathecal humoral immunoreaction in the form of oligoclonal bands (OCB is crucial in the diagnostic workup. To date, the impact of the 2010 McDonald criteria on the prevalence of OCB has not been investigated. We retrospectively evaluated data of 325 patients with a clinical relapse suggestive of demyelination that were treated in a German university hospital between 2010 and 2015. One hundred thirty-six patients (42% were diagnosed with MS and 189 patients with CIS when the criteria of 2010 were applied. The criteria of 2005 allowed only 70 patients (22% to be designated as MS. In contrast, the prevalence of OCB was marginal affected in MS patients with 96% for the criteria of 2010 and 98.5% for the criteria of 2005. In conclusion, OCB are prevalent in most MS patients and reflect the chronic inflammatory nature of the disease. We recommend CSF examination to exclude alternative diagnoses and reevaluation of the diagnosis MS in patients with negative OCB.

  1. EVALUATION OF ULTRASOUND REMISSION CRITERIA IN PATIENTS WITH RHEUMATOID ARTHRITIS DURING TOCILIZUMAB THERAPY

    OpenAIRE

    Rita Aleksandrovna Osipyants; D E Karateev; E Yu Panasyuk; G V Lukina; A V Smirnov; S I Glukhova; E N Aleksandrova; A V Volkov; E L Nasonov

    2013-01-01

    Objective: to study the association of ultrasound (US) remission criteria with the clinical and laboratory indicators of inflammatory activity, functional status, and X-ray changes in patients with rheumatoid arthritis (RA) during tocilizumab (TCZ) therapy.Subjects and methods. The trial included 36 patients with RA (meeting the 1987 American College of Rheumatology (ACR) criteria) who had received TCZ for 6 months. The authors made a clinical and laboratory assessment of RA activity (DAS28-C...

  2. 100ps UV/x-ray framing camera

    International Nuclear Information System (INIS)

    Eagles, R.T.; Freeman, N.J.; Allison, J.M.; Sibbett, W.; Sleat, W.E.; Walker, D.R.

    1988-01-01

    The requirement for a sensitive two-dimensional imaging diagnostic with picosecond time resolution, particularly in the study of laser-produced plasmas, has previously been discussed. A temporal sequence of framed images would provide useful supplementary information to that provided by time resolved streak images across a spectral region of interest from visible to x-ray. To fulfill this requirement the Picoframe camera system has been developed. Results pertaining to the operation of a camera having S20 photocathode sensitivity are reviewed and the characteristics of an UV/x-ray sensitive version of the Picoframe system are presented

  3. Effect of Electric Voltage and Current of X-ray Chamber on the Element inthe Zirconium Alloy Analysis X-ray by X-ray Fluorescence

    International Nuclear Information System (INIS)

    Yusuf-Nampira; Narko-Wibowo, L; Rosika-Krisnawati; Nudia-Barenzani

    2000-01-01

    The using of x-ray fluorescence in the chemical analysis depend heavilyon the parameters of x-ray chamber, for examples : electric voltage andelectric current. That parameter give effect in the result of determine ofSn, Cr, Fe and Ni in the zirconium alloy. 20 kV electric voltages are used onthe Mo x-ray chamber shall product x-ray of zirconium in the sample materialcan give effect in the stability of the analysis result (deviation more than5%). The result of analysis of elements in the zirconium alloy shall givedeviation less than 5% when using of electric voltage of the x-ray chamberless than 19 kV. The sensitivity of analysis can be reached by step upelectric current of x-ray chamber. (author)

  4. A sensitive and quantitative biosensing method for the determination of {gamma}-ray emitting radionuclides in surface water

    Energy Technology Data Exchange (ETDEWEB)

    Wolterbeek, H.Th.; Meer, A.J.G.M. van der [Technische Univ. Delft (Netherlands). Interfacultair Reactor Inst.

    1996-11-01

    A quantitative and sensitive biosensing method has been developed for the determination of {gamma}-ray emitting radionuclides in surface water. The method is based on the concept that at equilibrium the specific radioactivity in the biosensor is equal to the specific radioactivity in water. The method consists of the measurement of both the radionuclide and the element in the biosensor and the determination of the element level in water. This three-way analysis eliminates problems such as unpredictable biosensor behaviour, effects of water elemental composition or further abiotic parameters: what remains is the generally high enrichment (bioaccumulation factor BCF) of elements and radionuclides in the biosensor material. Measurements were performed with floating water plants (Azolla filiculoides Lamk., Spirodela polyrhiza/Lemna sp.) and the fully submerged water plant Ceratophyllum demersum L., which were sampled from ditch water. Concentrations of elements and radionuclides were determined in both water and biosensor plants, using Neutron Activation Analysis (NAA), ICP-MS, and {gamma}-ray spectrometry, respectively. For the latter, both 1 litre samples (Marinelli-geometry) and 1 cm{sup 3} samples (well-type detectors) were applied in measurements. (author).

  5. Thoracic injury rule out criteria and NEXUS chest in predicting the risk of traumatic intra-thoracic injuries: A diagnostic accuracy study.

    Science.gov (United States)

    Safari, Saeed; Radfar, Fatemeh; Baratloo, Alireza

    2018-05-01

    This study aimed to compare the diagnostic accuracy of NEXUS chest and Thoracic Injury Rule out criteria (TIRC) models in predicting the risk of intra-thoracic injuries following blunt multiple trauma. In this diagnostic accuracy study, using the 2 mentioned models, blunt multiple trauma patients over the age of 15 years presenting to emergency department were screened regarding the presence of intra-thoracic injuries that are detectable via chest x-ray and screening performance characteristics of the models were compared. In this study, 3118 patients with the mean (SD) age of 37.4 (16.9) years were studied (57.4% male). Based on TIRC and NEXUS chest, respectively, 1340 (43%) and 1417 (45.4%) patients were deemed in need of radiography performance. Sensitivity, specificity, and positive and negative predictive values of TIRC were 98.95%, 62.70%, 21.19% and 99.83%. These values were 98.61%, 59.94%, 19.97% and 99.76%, for NEXUS chest, respectively. Accuracy of TIRC and NEXUS chest models were 66.04 (95% CI: 64.34-67.70) and 63.50 (95% CI: 61.78-65.19), respectively. TIRC and NEXUS chest models have proper and similar sensitivity in prediction of blunt traumatic intra-thoracic injuries that are detectable via chest x-ray. However, TIRC had a significantly higher specificity in this regard. Copyright © 2018 Elsevier Ltd. All rights reserved.

  6. Population Studies of Radio and Gamma-Ray Pulsars

    Science.gov (United States)

    Harding, Alice K; Gonthier, Peter; Coltisor, Stefan

    2004-01-01

    Rotation-powered pulsars are one of the most promising candidates for at least some of the 40-50 EGRET unidentified gamma-ray sources that lie near the Galactic plane. Since the end of the EGRO mission, the more sensitive Parkes Multibeam radio survey has detected mere than two dozen new radio pulsars in or near unidentified EGRET sources, many of which are young and energetic. These results raise an important question about the nature of radio quiescence in gamma-ray pulsars: is the non-detection of radio emission a matter of beaming or of sensitivity? The answer is very dependent on the geometry of the radio and gamma-ray beams. We present results of a population synthesis of pulsars in the Galaxy, including for the first time the full geometry of the radio and gamma-ray beams. We use a recent empirically derived model of the radio emission and luminosity, and a gamma-ray emission geometry and luminosity derived theoretically from pair cascades in the polar slot gap. The simulation includes characteristics of eight radio surveys of the Princeton catalog plus the Parkes MB survey. Our results indicate that EGRET was capable of detecting several dozen pulsars as point sources, with the ratio of radio-loud to radio-quiet gamma-ray pulsars increasing significantly to about ten to one when the Parkes Survey is included. Polar cap models thus predict that many of the unidentified EGRET sources could be radio-loud gamma- ray pulsars, previously undetected as radio pulsars due to distance, large dispersion and lack of sensitivity. If true, this would make gamma-ray telescopes a potentially more sensitive tool for detecting distant young neutron stars in the Galactic plane.

  7. Semiconductor X-ray detectors

    CERN Document Server

    Lowe, Barrie Glyn

    2014-01-01

    Identifying and measuring the elemental x-rays released when materials are examined with particles (electrons, protons, alpha particles, etc.) or photons (x-rays and gamma rays) is still considered to be the primary analytical technique for routine and non-destructive materials analysis. The Lithium Drifted Silicon (Si(Li)) X-Ray Detector, with its good resolution and peak to background, pioneered this type of analysis on electron microscopes, x-ray fluorescence instruments, and radioactive source- and accelerator-based excitation systems. Although rapid progress in Silicon Drift Detectors (SDDs), Charge Coupled Devices (CCDs), and Compound Semiconductor Detectors, including renewed interest in alternative materials such as CdZnTe and diamond, has made the Si(Li) X-Ray Detector nearly obsolete, the device serves as a useful benchmark and still is used in special instances where its large, sensitive depth is essential. Semiconductor X-Ray Detectors focuses on the history and development of Si(Li) X-Ray Detect...

  8. Qualification criteria for persons responsible for radiation protection

    International Nuclear Information System (INIS)

    Wehner, G

    1980-01-01

    A survey of the qualification criteria included in the German atomic law (Atomic Energy Act, Radiological Protection Ordinance and X-ray Protection Ordinance) for persons responsible for radiation protection is given. Especially the various activities for which a health physics officer is required, the range of qualification in each case and the way the qualification has to be proved, are pointed out. Also the different guides that are issued to complete the legal requirements are mentioned. The definitions of the term qualification for health physics given in the different guides are cited and it is shown, that the qualification of a healt physics officer has to be based on the three criteria (I) vocational training. (II) professional experience and (III) the necessary knowledge in radiation protection. (orig./HP) [de

  9. Polarized X-ray excitation for scatter reduction in X-ray fluorescence computed tomography.

    Science.gov (United States)

    Vernekohl, Don; Tzoumas, Stratis; Zhao, Wei; Xing, Lei

    2018-05-25

    X-ray fluorescence computer tomography (XFCT) is a new molecular imaging modality which uses X-ray excitation to stimulate the emission of fluorescent photons in high atomic number contrast agents. Scatter contamination is one of the main challenges in XFCT imaging which limits the molecular sensitivity. When polarized X-rays are used, it is possible to reduce the scatter contamination significantly by placing detectors perpendicular to the polarization direction. This study quantifies scatter contamination for polarized and unpolarized X-ray excitation and determines the advantages of scatter reduction. The amount of scatter in preclinical XFCT is quantified in Monte Carlo simulations. The fluorescent X-rays are emitted isotropically, while scattered X-rays propagate in polarization direction. The magnitude of scatter contamination is studied in XFCT simulations of a mouse phantom. In this study, the contrast agent gold is examined as an example but a scatter reduction from polarized excitation is also expected for other elements. The scatter reduction capability is examined for different polarization intensities with a monoenergetic X-ray excitation energy of 82 keV. The study evaluates two different geometrical shapes of CZT detectors which are modeled with an energy resolution of 1 keV FWHM at an X-ray energy of 80 keV. Benefits of a detector placement perpendicular to the polarization direction are shown in iterative and analytic image reconstruction including scatter correction. The contrast to noise ratio (CNR) and the normalized mean square error (NMSE) are analyzed and compared for the reconstructed images. A substantial scatter reduction for common detector sizes was achieved for 100% and 80% linear polarization while lower polarization intensities provide a decreased scatter reduction. By placing the detector perpendicular to the polarization direction, a scatter reduction by factor up to 5.5 can be achieved for common detector sizes. The image

  10. Einstein pictures the x-ray sky

    International Nuclear Information System (INIS)

    Hartline, B.K.

    1979-01-01

    The second High Energy Astronomy Observatory (HEAO-2, Einstein) is revolutionizing x-ray astronomy just as its namesake revolutionized physics. Earlier x-ray observatories, including HEAO-1, were designed to scan the sky for x-ray emitters. With Einstein, the challenge has shifted from discovering x-ray sources to understanding the processes producing the x-rays. But having 500 times the sensitivity of previous detectors, Einstein makes more than its share of discoveries, too. For example, it sees distant quasars and clusters of galaxies that can barely be detected by the largest optical telescopes

  11. Review of GRANAT observations of gamma-ray bursts

    DEFF Research Database (Denmark)

    Terekhov, O.; Denissenko, D.; Sunyaev, R.

    1995-01-01

    The GRANAT observatory was launched into a high apogee orbit on 1 December, 1989. Three instruments onboard GRANAT - PHEBUS, WATCH and SIGMA are able to detect gamma-ray bursts in a very broad energy range from 6 keV up to 100 MeV. Over 250 gamma-ray bursts were detected. We discuss the results...... of the observations of the time histories and spectral evolution of the detected events provided by the different instruments in different energy ranges. Short Gamma-Ray Bursts ( 2 s) events. Evidence of the existence...... of four differently behaving componenents in gamma-ray burst spectra is discussed. Statistical properties of the gamma-ray burst sources based on the 5 years of observations with (∼ 10−6 erg/cm2) sensitivity as well as the results of high sensitivity (∼ 10−8 erg/cm2) search for Gamma-Ray Bursts within...

  12. Image formation in diagnostic X-ray equipment

    International Nuclear Information System (INIS)

    Boer, J.A. den.

    1983-01-01

    This thesis deals with a physical description of the image formation in static radiographic shadow image X-ray equipment and an analysis of the optimization of such systems. For the latter criteria have been developed that take into account all relevant physical phenomena that relate to properties of the image and the radiation exposure of the patient. The discussion of image formation results in a number of relations between the X-ray system parameters on the one hand and properties of the X-ray image on the other. The three principal aspects considered are energy transfer, modulation transfer and noise. (Auth./C.F.)

  13. Optics Developments for X-Ray Astronomy

    Science.gov (United States)

    Ramsey, Brian

    2014-01-01

    X-ray optics has revolutionized x-ray astronomy. The degree of background suppression that these afford, have led to a tremendous increase in sensitivity. The current Chandra observatory has the same collecting area (approx. 10(exp 3)sq cm) as the non-imaging UHURU observatory, the first x-ray observatory which launched in 1970, but has 5 orders of magnitude more sensitivity due to its focusing optics. In addition, its 0.5 arcsec angular resolution has revealed a wealth of structure in many cosmic x-ray sources. The Chandra observatory achieved its resolution by using relatively thick pieces of Zerodur glass, which were meticulously figured and polished to form the four-shell nested array. The resulting optical assembly weighed around 1600 kg, and cost approximately $0.5B. The challenge for future x-ray astronomy missions is to greatly increase the collecting area (by one or more orders of magnitude) while maintaining high angular resolution, and all within realistic mass and budget constraints. A review of the current status of US optics for x-ray astronomy will be provided along with the challenges for future developments.

  14. Total-reflection x-ray fluorescence with a brillant undulator x-ray source

    International Nuclear Information System (INIS)

    Sakurai, K.; Eba, H.; Numako, C.; Suzuki, M.; Inoue, K.; Yagi, N.

    2000-01-01

    Total-reflection x-ray fluorescence (TXRF) is a highly sensitive technique for analyzing trace elements, because of the very low background from the sample support. Use of third-generation synchrotron x-ray source could further enhance the detection power. However, while such high sensitivity permits the detection of signals from trace elements of interest, it also means that one can observe weak parasitic x-rays as well. If the sample surface becomes even slightly contaminated, owing to air particulates near the beamline, x-ray fluorescence lines of iron, zinc, copper, nickel, chromium, and titanium can be observed even for a blank sample. Another critical problem is the low-energy-side tail of the scattering x-rays, which ultimately restricts the detection capability of the technique using a TXRF spectrometer based on a Si(Li) detector. The present paper describes our experiments with brilliant undulator x-ray beams at BL39XU and BL40XU, at the SPring-8, Harima, Japan. The emphasis is on the development of instruments to analyze a droplet of 0.1 μl containing trace elements of ppb level. Although the beamline is not a clean room, we have employed equipment for preparing a clean sample and also for avoiding contamination during transferring the sample into the spectrometer. We will report on the successful detection of the peak from 0.8 ppb selenium in a droplet (absolute amount 80 fg). We will also present the results of recent experiments obtained from a Johansson spectrometer rather than a Si(Li) detector. (author)

  15. Gamma-ray astrophysics

    International Nuclear Information System (INIS)

    Fichtel, C.E.

    1977-01-01

    The most striking feature of the celestial sphere when viewed in the frequency range of γ-rays is the emission from the galactic plane, which is particularly intense in the galactic longitudinal region from 300 0 to 50 0 . The longitudinal and latitudinal distributions are generally correlated with galactic structural features and when studied in detail suggest a non-uniform distribution of cosmic rays in the galaxy. Several point γ-ray sources have now been observed, including four radio pulsars. This last result is particularly striking since only one radio pulsar has been seen at either optical or X-ray frequencies. Nuclear γ-ray lines have been seen from the Sun during a large solar flare and future satellite experiments are planned to search for γ-ray lines from supernovae and their remnants. A general apparently diffuse flux of γ-rays has also been seen whose energy spectrum has interesting implications; however, in view of the possible contribution of point sources and the observation of galactic features such as Gould's belt, its interpretation must await γ-ray experiments with finer spatial and energy resolution, as well as greater sensitivity. (Auth.)

  16. Prevalence and Diagnostic Performance of Isolated and Combined NEXUS Chest CT Decision Criteria.

    Science.gov (United States)

    Raja, Ali S; Mower, William R; Nishijima, Daniel K; Hendey, Gregory W; Baumann, Brigitte M; Medak, Anthony J; Rodriguez, Robert M

    2016-08-01

    The use of chest computed tomography (CT) to evaluate emergency department patients with adult blunt trauma is rising. The NEXUS Chest CT decision instruments are highly sensitive identifiers of adult blunt trauma patients with thoracic injuries. However, many patients without injury exhibit one of more of the criteria so cannot be classified "low risk." We sought to determine screening performance of both individual and combined NEXUS Chest CT criteria as predictors of thoracic injury to inform chest CT imaging decisions in "non-low-risk" patients. This was a secondary analysis of data on patients in the derivation and validation cohorts of the prospective, observational NEXUS Chest CT study, performed September 2011 to May 2014 in 11 Level I trauma centers. Institutional review board approval was obtained at all study sites. Adult blunt trauma patients receiving chest CT were included. The primary outcome was injury and major clinical injury prevalence and screening performance in patients with combinations of one, two, or three of seven individual NEXUS Chest CT criteria. Across the 11 study sites, rates of chest CT performance ranged from 15.5% to 77.2% (median = 43.6%). We found injuries in 1,493/5,169 patients (28.9%) who had chest CT; 269 patients (5.2%) had major clinical injury (e.g., pneumothorax requiring chest tube). With sensitivity of 73.7 (95% confidence interval [CI] = 68.1 to 78.6) and specificity of 83.9 (95% CI = 83.6 to 84.2) for major clinical injury, abnormal chest-x-ray (CXR) was the single most important screening criterion. When patients had only abnormal CXR, injury and major clinical injury prevalences were 60.7% (95% CI = 52.2% to 68.6%) and 12.9% (95% CI = 8.3% to 19.4%), respectively. Injury and major clinical injury prevalences when any other single criterion alone (other than abnormal CXR) was present were 16.8% (95% CI = 15.2% to 18.6%) and 1.1% (95% CI = 0.1% to 1.8%), respectively. Injury and major clinical injury prevalences

  17. JEM-X: The X-ray monitor on INTEGRAL

    DEFF Research Database (Denmark)

    Lund, Niels; Budtz-Jørgensen, Carl; Westergaard, Niels Jørgen Stenfeldt

    1999-01-01

    and identification of gamma ray sources as well as in the analysis and scientific interpretation of the combined X-ray and gamma ray data. JEM-X is a coded aperture X-ray telescope consisting of two identical detectors. Each detector has a sensitive area of 500 cm(2), and views the sky (6.6 deg FOV, FWHM) through...

  18. A wide field X-ray camera

    International Nuclear Information System (INIS)

    Sims, M.; Turner, M.J.L.; Willingale, R.

    1980-01-01

    A wide field of view X-ray camera based on the Dicke or Coded Mask principle is described. It is shown that this type of instrument is more sensitive than a pin-hole camera, or than a scanning survey of a given region of sky for all wide field conditions. The design of a practical camera is discussed and the sensitivity and performance of the chosen design are evaluated by means of computer simulations. The Wiener Filter and Maximum Entropy methods of deconvolution are described and these methods are compared with each other and cross-correlation using data from the computer simulations. It is shown that the analytic expressions for sensitivity used by other workers are confirmed by the simulations, and that ghost images caused by incomplete coding can be substantially eliminated by the use of the Wiener Filter and the Maximum Entropy Method, with some penalty in computer time for the latter. The cyclic mask configuration is compared with the simple mask camera. It is shown that when the diffuse X-ray background dominates, the simple system is more sensitive and has the better angular resolution. When sources dominate the simple system is less sensitive. It is concluded that the simple coded mask camera is the best instrument for wide field imaging of the X-ray sky. (orig.)

  19. Uniform research case definition criteria differentiate tuberculous and bacterial meningitis in children.

    Science.gov (United States)

    Solomons, Regan S; Wessels, Marie; Visser, Douwe H; Donald, Peter R; Marais, Ben J; Schoeman, Johan F; van Furth, Anne M

    2014-12-01

    Tuberculous meningitis (TBM) research is hampered by low numbers of microbiologically confirmed TBM cases and the fact that they may represent a select part of the disease spectrum. A uniform TBM research case definition was developed to address these limitations, but its ability to differentiate TBM from bacterial meningitis has not been evaluated. We assessed all children treated for TBM from 1985 to 2005 at Tygerberg Children's Hospital, Cape Town, South Africa. For comparative purposes, a group of children with culture-confirmed bacterial meningitis, diagnosed between 2003 and 2009, was identified from the National Health Laboratory Service database. The performance of the proposed case definition was evaluated in culture-confirmed TBM and bacterial meningitis cases. Of 554 children treated for TBM, 66 (11.9%) were classified as "definite TBM," 408 (73.6%) as "probable TBM," and 72 (13.0%) as "possible TBM." "Probable TBM" criteria identified culture-confirmed TBM with a sensitivity of 86% and specificity of 100%; sensitivity was increased but specificity reduced when using "possible TBM" criteria (sensitivity 100%, specificity 56%). "Probable TBM" criteria accurately differentiated TBM from bacterial meningitis and could be considered for use in clinical trials; reduced sensitivity in children with early TBM (stage 1 disease) remains a concern. © The Author 2014. Published by Oxford University Press on behalf of the Infectious Diseases Society of America. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  20. Very high energy gamma ray astrophysics

    International Nuclear Information System (INIS)

    Lamb, R.C.; Lewis, D.A.

    1986-01-01

    The Whipple Observatory's atmospheric Cerenkov camera has detected TeV radiation from four galactic sources: the Crab Nebula, Cygnus X-3, Hercules X-1, and 4U0115+63. Recent simulations encourage the view that unwanted cosmic-ray background showers may be suppressed by a large factor. Emphasis in the coming year will be on determining optimum selection criteria for enhancing gamma-ray signals and in developing a prototype camera with finer angular resolution as a first step towards implementation of the HERCULES concept

  1. Sensitivity of T lymphocytes to gamma rays in patients with cervix tumor

    Energy Technology Data Exchange (ETDEWEB)

    Oueslati, R; Kdous, CH; Chouikha, M [Lab. Immunology, Hopital de Tunis, (Tunisia); Maalej, M; Kochbati, N [Service Radiotherapy, Institut Salah Azeiz, (Tunisia)

    1995-10-01

    In this work we studied the effect of radiotherapy on normal cells in patients with cervix tumors treated only by gamma rays. In our laboratory, after lymphocytes separation, we tested the proliferation system of these cells against the phytohemagglutinin and the concanavalin a antigens; at the same time we tested their sensitivity to lys the erythroid tumor cells line K 562. According to the clinical stage of disease the 25 patients studied were divided in two groups; group I composed of 14 patients at stage I and II proximal, received 50 Gy from a cesium 137 source, in intrauterine and in continuous treatment during 4 days. The second group composed of 11 patients at stage II distal and III, received 50 Gy from a cobalt-60 source in extra uterine, the treatment is fractioned in 3 to 5 times per week, at each time the patient received 1,5 - 3 Gy. To compare with their immunological status before treatment, until 1 month after total dose received, all of our patients lost transitory their capacity to prolifere in vitro. Although the capacity to lys the tumor cells is diminished in cancer patients, the drop of this activity is principally. The selective recuperation of T lymphocytes stimulated by concanavalin A is also observed. 3 figs., 2 tabs.

  2. Sensitivity of T lymphocytes to gamma rays in patients with cervix tumor

    International Nuclear Information System (INIS)

    Oueslati, R.; Kdous, CH.; Chouikha, M.; Maalej, M.; Kochbati, N.

    1995-01-01

    In this work we studied the effect of radiotherapy on normal cells in patients with cervix tumors treated only by gamma rays. In our laboratory, after lymphocytes separation, we tested the proliferation system of these cells against the phytohemagglutinin and the concanavalin a antigens; at the same time we tested their sensitivity to lys the erythroid tumor cells line K 562. According to the clinical stage of disease the 25 patients studied were divided in two groups; group I composed of 14 patients at stage I and II proximal, received 50 Gy from a cesium 137 source, in intrauterine and in continuous treatment during 4 days. The second group composed of 11 patients at stage II distal and III, received 50 Gy from a cobalt-60 source in extra uterine, the treatment is fractioned in 3 to 5 times per week, at each time the patient received 1,5 - 3 Gy. To compare with their immunological status before treatment, until 1 month after total dose received, all of our patients lost transitory their capacity to prolifere in vitro. Although the capacity to lys the tumor cells is diminished in cancer patients, the drop of this activity is principally. The selective recuperation of T lymphocytes stimulated by concanavalin A is also observed. 3 figs., 2 tabs

  3. Pre-validation of the WHO organ dysfunction based criteria for identification of maternal near miss

    Directory of Open Access Journals (Sweden)

    Parpinelli Mary A

    2011-08-01

    Full Text Available Abstract Background To evaluate the performance of the WHO criteria for defining maternal near miss and identifying deaths among cases of severe maternal morbidity (SMM admitted for intensive care. Method Between October 2002 and September 2007, 673 women with SMM were admitted, and among them 18 died. Variables used for the definition of maternal near miss according to WHO criteria and for the SOFA score were retrospectively evaluated. The identification of at least one of the WHO criteria in women who did not die defined the case as a near miss. Organ failure was evaluated through the maximum SOFA score above 2 for each one of the six components of the score, being considered the gold standard for the diagnosis of maternal near miss. The aggregated score (Total Maximum SOFA score was calculated using the worst result of the maximum SOFA score. Sensitivity, specificity, positive and negative predictive values of these WHO criteria for predicting maternal death and also for identifying cases of organ failure were estimated. Results The WHO criteria identified 194 cases of maternal near miss and all the 18 deaths. The most prevalent criteria among cases of maternal deaths were the use of vasoactive drug and the use of mechanical ventilation (≥1 h. For the prediction of maternal deaths, sensitivity was 100% and specificity 70.4%. These criteria identified 119 of the 120 cases of organ failure by the maximum SOFA score (Sensitivity 99.2% among 194 case of maternal near miss (61.34%. There was disagreement in 76 cases, one organ failure without any WHO criteria and 75 cases with no failure but with WHO criteria. The Total Maximum SOFA score had a good performance (area under the curve of 0.897 for prediction of cases of maternal near miss according to the WHO criteria. Conclusions The WHO criteria for maternal near miss showed to be able to identify all cases of death and almost all cases of organ failure. Therefore they allow evaluation of the

  4. Development and prospects of X-ray computerized tomography. I

    International Nuclear Information System (INIS)

    Dobes, V.

    1985-01-01

    The history and developmental trends are described of X-ray computerized tomography (CT) as are its applications in clinical practise. Suitable criteria and economic aspects are proposed for the choice of CT systems. The types are listed and described of X-ray CT systems, including brain, whole-body, mobile and special systems. A table is given showing available specifications (types of detectors, X-ray source, resolution, configuration, scan angles, scan fields, image reconstruction, etc.) for machines by different companies. (M.D.)

  5. The MCNP simulation of the X-ray leakage of X-ray security inspection equipment

    International Nuclear Information System (INIS)

    Wang Kai; Liu Bin; Hu Wenchao; Zhao Wei

    2011-01-01

    Objective: To simulate the radiation leakage of the X-ray security inspection equipment used in the subways stations. Methods: We use the MCNP4C code to simulate the X-ray leakage of the equipment during the working process. Result: the biggest amount of radiation received by the body is 8.26 μSv/a, however, if the Lead screens of the X-ray security equipment is intact, the amount of radiation received by the body is only 0.0727 μSv/a. The final. Conclusions: When the baggage get in /out the X-ray security inspection equipment, the gas in Lead screens was made, and then the amount of radiation received by human body increased; The amount of radiation received by the body is close to but still below 10 μSv/a which is the exemption criteria set by the 'safety of radiation sources of ionizing radiation protection and basic standards'(GB18871-2002). (authors)

  6. The X-ray Telescope for the SWIFT Gamma-Ray Burst Mission

    International Nuclear Information System (INIS)

    Wells, A.; Abbey, A.F.; Beardmore, A.; Mukerjee, K.; Osborne, J.P.; Watson, D.J.; Willingale, R.; Burrows, D. N.; Hill, J. E.; Nousek, J.A.; Miles, B.J.; Mori, K.; Morris, D.C.; Zugger, M.; Chincarini, G.; Campana, S.; Citterio, O.; Moretti, A.; Tagliaferri, G.; Bosworth, J.

    2004-01-01

    The X-ray Telescope (XRT) for the SWIFT mission, built by the international consortium from Pennsylvania State University (United States), University of Leicester (UK) and Osservatorio Astronomico di Brera (Italy), is already installed on the SWIFT spacecraft. The XRT has two key functions on SWIFT; to determine locations of GRBs to better than 5 arc seconds within 100 seconds of initial detection of a burst and to measure spectra and light curves of the X-ray afterglow over around four orders of magnitude of decay in the afterglow intensity. This paper summarises the XRT performance, operating modes and sensitivity for the detection of prompt and extended X-ray afterglows from gamma-ray bursts. The performance characteristics have been determined from data taken during the ground calibration campaign at MPE's Panter facility in September 2002

  7. Preliminary investigation of the NMR, optical and x-ray CT dose-response of polymer gel dosimeters incorporating cosolvents to improve dose sensitivity

    International Nuclear Information System (INIS)

    Koeva, V I; McAuley, K B; Olding, T; Jirasek, A; Schreiner, L J

    2009-01-01

    This study reports on efforts to increase the dose sensitivity of polymer gel dosimeters used in 3D radiation dosimetry. The potential of several different cosolvents is investigated, with the aim of increasing the solubility of N,N'-methylene-bisacrylamide crosslinker in polymer gel dosimeters. Glycerol and isopropanol increase the limit for the crosslinker solubility from approximately 3% to 5% and 10% by weight, respectively. This enables the manufacture of polymer gel dosimeters with much higher levels of crosslinking than was previously possible. New dosimeter recipes containing up to 5 wt% N,N'-methylene-bisacrylamide were subjected to spatially uniform radiation and were studied using nuclear magnetic resonance (NMR), as well as x-ray and optical CT techniques. The resulting dosimeters exhibit dose sensitivities that are up to 2.7 times higher than measured for a typical dosimeters with 3% N,N'-methylene-bisacrylamide without the addition of cosolvent. Two additional cosolvents (n-propanol and sec-butanol) were deemed unsuitable for practical dosimeters due to incompatibility with gelatin, cloudiness prior to irradiation, and immiscibility with water when large quantities of cosolvent were used. The dosimeters with high N,N'-methylene-bisacrylamide content that used isopropanol or glycerol as cosolvents had high optical clarity prior to irradiation, but did not produce suitable optical CT results for non-uniformly irradiated gels due to polymer development outside of the high dose regions of the pencil beams and significant light scatter. Further experiments are required to determine whether cosolvents can be used to manufacture gels with sufficiently high dose sensitivity for readout using x-ray computed tomography.

  8. Use of a solar panel as a directionally sensitive large-area radiation monitor for direct and scattered x-rays and gamma-rays.

    Science.gov (United States)

    Abdul-Majid, S

    1987-01-01

    The characteristics of a 25.4 X 91 cm solar cell panel used as an x-ray and gamma-ray radiation monitor are presented. Applications for monitoring the primary x-ray beam are described at different values of operating currents and voltages as well as for directional dependence of scattered radiation. Other applications in gamma-ray radiography are also given. The detector showed linear response to both x-ray and gamma-ray exposures. The equipment is rigid, easy to use, relatively inexpensive and requires no power supply or any complex electronic equipment.

  9. X-ray-to-current signal conversion characteristics of trench-structured photodiodes for direct-conversion-type silicon X-ray sensor

    International Nuclear Information System (INIS)

    Ariyoshi, Tetsuya; Funaki, Shota; Sakamoto, Kenji; Baba, Akiyoshi; Arima, Yutaka

    2017-01-01

    To reduce the radiation dose required in medical X-ray diagnoses, we propose a high-sensitivity direct-conversion-type silicon X-ray sensor that uses trench-structured photodiodes. This sensor is advantageous in terms of its long device lifetime, noise immunity, and low power consumption because of its low bias voltage. With this sensor, it is possible to detect X-rays with almost 100% efficiency; sensitivity can therefore be improved by approximately 10 times when compared with conventional indirect-conversion-type sensors. In this study, a test chip was fabricated using a single-poly single-metal 0.35 μm process. The formed trench photodiodes for the X-ray sensor were approximately 170 and 300 μm deep. At a bias voltage of 25 V, the absorbed X-ray-to-current signal conversion efficiencies were 89.3% (theoretical limit; 96.7%) at a trench depth of 170 μm and 91.1% (theoretical limit; 94.3%) at a trench depth of 300 μm. (author)

  10. X-Ray Polarimetry with GEMS

    Science.gov (United States)

    Strohmayer, Tod

    2011-01-01

    The polarization properties of cosmic X-ray sources are still largely unexplored. The Gravity and Extreme Magnetism SMEX (GEMS) will carry out the first sensitive X-ray polarization survey of a wide range of sources including; accreting compact objects (black holes and neutron stars), AGN, supernova remnants, magnetars and rotation-powered pulsars. GEMS employs grazing-incidence foil mirrors and novel time-projection chamber (TPC) polarimeters leveraging the photoelectric effect to achieve high polarization sensitivity in the 2 - 10 keV band. I will provide an update of the project status, illustrate the expected performance with several science examples, and provide a brief overview of the data analysis challenges

  11. Probabilistic safety criteria on high burnup HWR fuels

    International Nuclear Information System (INIS)

    Marino, A.C.

    2002-01-01

    BACO is a code for the simulation of the thermo-mechanical and fission gas behaviour of a cylindrical fuel rod under operation conditions. Their input parameters and, therefore, output ones may include statistical dispersion. In this paper, experimental CANDU fuel rods irradiated at the NRX reactor together with experimental MOX fuel rods and the IAEA-CRP FUMEX cases are used in order to determine the sensitivity of BACO code predictions. The techniques for sensitivity analysis defined in BACO are: the 'extreme case analysis', the 'parametric analysis' and the 'probabilistic (or statistics) analysis'. We analyse the CARA and CAREM fuel rods relation between predicted performance and statistical dispersion in order of enhanced their original designs taking account probabilistic safety criteria and using the BACO's sensitivity analysis. (author)

  12. Comparison of heat and/or radiation sensitivity and membrane composition of seven X-ray-transformed C3H 10T1/2 cell lines and normal C3H 10T1/2 cells

    International Nuclear Information System (INIS)

    Raaphorst, G.P.; Vadasz, J.A.; Azzam, E.I.; Sargent, M.D.; Borsa, J.; Einspenner, M.

    1985-01-01

    C3H 10T1/2 mouse embryo cells were transformed by X-irradiation, and seven transformed clones were isolated and propagated as cell lines. Some of these cell lines produced tumors in syngeneic mice and grew in agarose while the normal C3H 10T1/2 cell line did not possess these characteristics. Exponentially growing cell cultures with comparable cell-cycle distributions as measured by flow cytometry were tested for heat and X-ray sensitivity. The heat and X-ray sensitivity varied randomly compared to the normal cell line. One cell line was more heat resistant and one more heat sensitive than the normal cell line, and the others had sensitivities comparable to the normal cell line. Measurements on some of the biochemical parameters of the particulate fraction of cells after sonication and 24,000 X g centrifugation showed that altered thermal sensitivity was not correlated with protein, cholesterol, or phospholipid content of this fraction

  13. Application of National Emergency X-Ray Utilizations Study low-risk c-spine criteria in high-risk geriatric falls.

    Science.gov (United States)

    Evans, Daniel; Vera, Luis; Jeanmonod, Donald; Pester, Jonathan; Jeanmonod, Rebecca

    2015-09-01

    We sought to validate National Emergency X-Radiography Utilizations Study low-risk cervical spine (C spine) criteria in a geriatric trauma population. We sought to determine whether patients' own baseline mental status (MS) could substitute for Glasgow Coma Scale (GCS) to meet the criteria "normal alertness." We further sought to refine the definition of "distracting injury." This is a retrospective review of geriatric fall patients presenting to a level 1 trauma center and triaged to the trauma bay. We queried our database from 2008 to 2013. Abstractors recorded GCS, deviation from baseline MS, midline neck tenderness, intoxication, focal deficit, signs of trauma, and presence of other injury. Patients were considered at baseline MS if specific documentation was present on the chart, or if their GCS was 15. Six hundred sixty elderly fall patients were trauma alerts during the study period. Seventeen were excluded for incomplete records/death before imaging, leaving 647. The median age was 81 (interquartile range, 74-87). Fifty patients (8.0%) had C spine or cord injury. Two hundred ninety-four (44.5%) had baseline MS (including GCS 13-15), no spine tenderness, no intoxication, and no focal neurologic deficit. Of these, 18 had C-spine injury. Using physical findings of head trauma as the only "distracting injury," no injury would have been missed (sensitivity, 100% [confidence interval, 91.1-100]; specificity, 14.2%). Our study suggests that National Emergency X-Radiography Utilizations Study can be safely applied in elderly fall patients who are at their personal baseline MS. Furthermore, our data support a more narrow definition of distracting injury to include only patients with signs of trauma to the head. Copyright © 2015 Elsevier Inc. All rights reserved.

  14. The Fermi GBM Gamma-Ray Burst Catalog: The First Two Years

    NARCIS (Netherlands)

    Paciesas, W.S.; Meegan, C.A.; von Kienlin, A.; Bhat, P.N.; Bissaldi, E.; Briggs, M.S.; M. Burgess, J.; Chaplin, V.; Connaughton, V.; Diehl, R.; Fishman, G.J.; Fitzpatrick, G.; Foley, S.; H. Gibby, M.; Giles, M.; Goldstein, A.; Greiner, J.; Gruber, D.; Guiriec, S.; van der Horst, A.J.; Kippen, R.M.; Kouveliotou, C.; Lichti, G.; Lin, L.; McBreen, S.; Preece, R.D.; Rau, A.; Tierney, D.; Wilson-Hodge, C.

    2012-01-01

    The Fermi Gamma-ray Burst Monitor (GBM) is designed to enhance the scientific return from Fermi in studying gamma-ray bursts (GRBs). In its first two years of operation GBM triggered on 491 GRBs. We summarize the criteria used for triggering and quantify the general characteristics of the triggered

  15. [Inappropriate prescription in older patients: the STOPP/START criteria].

    LENUS (Irish Health Repository)

    Delgado Silveira, Eva

    2009-09-01

    Older people are a heterogeneous group of patients, often with multiple comorbidities for which they are prescribed a large number of drugs, leading to an increased risk of adverse drug reactions (ADR) and drug interactions. This risk is compounded by physiological age-related changes in physiology, changes in drug pharmacokinetics and pharmacodynamics, as well as by disease-related, functional and social issues. Inappropriate prescription of drugs is common in the older individuals and contributes to the increased risk of ADR. Several tools have been developed to detect potentially inappropriate prescription, the most frequently used in Spain being Beers\\' criteria. However, the value of these criteria is limited, especially as they were developed in a different healthcare system. In this article, the Spanish version of a new tool to detect potentially inappropriate prescriptions-STOPP (Screening Tool of Older Person\\'s Prescriptions) and START (Screening Tool to Alert doctors to Right i.e. appropriate, indicated Treatment) criteria-is presented. The creation, development, reliability, and use of these criteria in routine practice is described and discussed. These criteria have shown better sensitivity than Beers\\' criteria in detecting prescription problems and have the added value of being able to detect not only inappropriate prescription of some drugs, but also the omission of well indicated drugs. The STOPP\\/START criteria could become a useful screening tool to improve prescription in older people.

  16. X-ray fluorescence analyzer arrangement

    International Nuclear Information System (INIS)

    Vatai, Endre; Ando, Laszlo; Gal, Janos.

    1981-01-01

    An x-ray fluorescence analyzer for the quantitative determination of one or more elements of complex samples is reported. The novelties of the invention are the excitation of the samples by x-rays or γ-radiation, the application of a balanced filter pair as energy selector, and the measurement of the current or ion charge of ionization detectors used as sensors. Due to the increased sensitivity and accuracy, the novel design can extend the application fields of x-ray fluorescence analyzers. (A.L.)

  17. Code of safe practice for the use of x-rays in podiatry

    International Nuclear Information System (INIS)

    1990-02-01

    The purpose of this code which applies to podiatric diagnostic use of x-rays is to provide criteria for working procedures, x-ray equipment and protective materials necessary for the use of x-rays in podiatric diagnosis according to currently accepted standards of safety. Conformity with this code may be taken as a primary indication of compliance with radiation protection legislation. 5 refs

  18. The γ-ray burst-detection system of SPI

    International Nuclear Information System (INIS)

    Lichti, G.G.; Georgii, R.; Kienlin, A. von; Schoenfelder, V.; Wunderer, C.; Jung, H.-J.; Hurley, K.

    2000-01-01

    The determination of precise locations of γ-ray bursts is a crucial task of γ-ray astronomy. Although γ-ray burst locations can be obtained nowadays from single experiments (BATSE, COMPTEL, BeppoSax) the location of bursts via triangulation using the interplanetary network is still important because not all bursts will be located precisely enough by these single instruments. In order to get location accuracies down to arcseconds via triangulation one needs long baselines. At the beginning of the next decade several spacecrafts which explore the outer planetary system (the Mars-Surveyor-2001 Orbiter and probably Ulysses) will carry γ-ray burst instruments. INTEGRAL as a near-earth spacecraft is the ideal counterpart for these satellites. The massive anticoincidence shield of the INTEGRAL-spectrometer SPI allows the measurement of γ-ray bursts with a high sensitivity. Estimations have shown that with SPI some hundred γ-ray bursts per year on the 5σ level can be measured. This is equivalent to the BATSE sensitivity. We describe the γ-ray burst-detection system of SPI, present its technical features and assess the scientific capabilities

  19. Transforming Our Understanding of the X-ray Universe: The Imaging X-ray Polarimeter Explorer (IXPE)

    Science.gov (United States)

    Weisskopf, Martin C.; Bellazzini, Ronaldo; Costa, Enrico; Matt, Giorgio; Marshall, Herman; ODell, Stephen L.; Pavlov, George; Ramsey, Brian; Romani, Roger

    2014-01-01

    Accurate X-ray polarimetry can provide unique information on high-energy-astrophysical processes and sources. As there have been no meaningful X-ray polarization measurements of cosmic sources since our pioneering work in the 1970's, the time is ripe to explore this new parameter space in X-ray astronomy. To accomplish this requires a well-calibrated and well understood system that-particularly for an Explorer mission-has technical, cost, and schedule credibility. The system that we shall present satisfies these conditions, being based upon completely calibrated imaging- and polarization-sensitive detectors and proven X-ray-telescope technology.

  20. Picosecond x-ray streak camera studies

    International Nuclear Information System (INIS)

    Kasyanov, Yu.S.; Malyutin, A.A.; Richardson, M.C.; Chevokin, V.K.

    1975-01-01

    Some initial results of direct measurement of picosecond x-ray emission from laser-produced plasmas are presented. A PIM-UMI 93 image converter tube, incorporating an x-ray sensitive photocathode, linear deflection, and three stages of image amplification was used to analyse the x-ray radiation emanating from plasmas produced from solid Ti targets by single high-intensity picosecond laser pulses. From such plasmas, the x-ray emission typically persisted for times of 60psec. However, it is shown that this detection system should be capable of resolving x-ray phenomena of much shorter duration. (author)

  1. Release criteria for patients having undergone radionuclide therapy and criteria for their crossing the state border of the Russian Federation

    International Nuclear Information System (INIS)

    Zvonova, I.; Balonov, M.; Golikov, V.

    2011-01-01

    By means of a conservative dosimetry model, the values of operational radiological criteria for patients released from hospital-residual activity in a body and dose rate near the patient's body-are substantiated based on the effective dose limit of 5 mSv for persons helping the patient or living with him and 1 mSv for other adults and children. Two sets of operative criteria for radionuclides 125 I, 131 I, 153 Sm and 188 Re used in Russia for radionuclide therapy were derived. Release criteria for 125 I well differ from such values in other countries because in this work absorption of 125 I low-energy photon radiation in the patient was taken into account. When a patient having undergone radionuclide therapy crosses the frontier of Russia, high-sensitivity devices for radiation control at the custom can detect the patient. A simplified radiological assessment of the patient was suggested aimed at provision of radiation safety for patient companions in transport. (authors)

  2. Development of multi-color scintillator based X-ray image intensifier

    International Nuclear Information System (INIS)

    Nittoh, Koichi; Konagai, Chikara; Noji, Takashi

    2004-01-01

    A multi-color scintillator based high-sensitive, wide dynamic range and long-life X-ray image intensifier has been developed. An europium activated Y 2 O 2 S scintillator, emitting red, green and blue photons of different intensities, is utilized as the output fluorescent screen of the intensifier. By combining this image intensifier with a suitably tuned high sensitive color CCD camera, it is possible for a sensitivity of the red color component to become six times higher than that of the conventional image intensifier. Simultaneous emission of a moderate green color and a weak blue color covers different sensitivity regions. This widens the dynamic range, by nearly two orders of ten. With this image intensifier, it is possible to image simultaneously complex objects containing various different X-ray transmission from paper, water or plastic to heavy metals. This high sensitivity intensifier, operated at lower X-ray exposure, causes less degradation of scintillator materials and less colorization of output screen glass, and thus helps achieve a longer lifetime. This color scintillator based image intensifier is being introduced for X-ray inspection in various fields

  3. An apparatus for high speed measurements of small-angle x-ray scattering profiles with a linear position sensitive detector

    International Nuclear Information System (INIS)

    Hashimoto, Takeji; Suehiro, Shoji; Shibayama, Mitsuhiro; Saijo, Kenji; Kawai, Hiromichi

    1981-01-01

    An apparatus for high speed measurements of small-angle X-ray scattering (SAXS) is described. This apparatus utilizes a 12 kW rotating anode X-ray generator, a linear position sensitive proportional counter (multicathode delay line PSPC), and a two-parameter multichannel pulse height analyzer (MCA) with 12 kwords (16 bits/word) memory area available for SAXA intensity data as a function of position (scattering angles) and time slice. The two-parameter MCA is constructed within a microcomputer system, by utilizing its R/W memory for data storage, and the memory incrementing and real-time CRT display is implemented by using two direct memory access (DMA) controllers. The cycle time of the access is about 10 μs. The measuring time for SAXS profiles with this apparatus can be shortened approximately by three orders of magnitude in comparison with the measuring time with SAXS apparatuses utilizing a conventional step-scanning goniometer and a conventional X-ray tube, thus permitting time-resolved analyses of SAXS profiles. Some applications of the apparatus to dynamic SAXS measurements are presented for polymeric systems, the preliminary results of which seem to indicate the possibility of obtaining a new class of data on dynamics in structural transformation, deformation, formation and annihilation in the scale of a few tens to several hundred Angstroms. (author)

  4. A primary scintillation gated high pressure position sensitive gas scintillation proportional counter (HPGSPC) for applications to x-ray astronomy

    International Nuclear Information System (INIS)

    Giarrusso, S.; Manzo, G.; Re, S.

    1985-01-01

    The authors describe a new instrument for x-ray astronomy. The instrument, based on a high pressure (5 atm.), xenon filled, position sensitive Gas Scintillation Proportional counter (HPGSPC) is expected to feature an energy resolution better than 4% at 60 keV, an angular resolution of approximately 20 arc-minutes over the full energy range (4 to 100 keV) and a field of view (FOV) of up to 30x30 degrees. A prototype flight unit of the gas cell on which the instrument is based is presently under technological development in the framework of the SAX project

  5. Gamma-Ray, Cosmic Ray and Neutrino Tests of Lorentz Invariance and Quantum Gravity Models

    Science.gov (United States)

    Stecker, Floyd

    2011-01-01

    High-energy astrophysics observations provide the best possibilities to detect a very small violation of Lorentz invariance such as may be related to the structure of space-time near the Planck scale of approximately 10(exp -35) m. I will discuss here the possible signatures of Lorentz invariance violation (LIV) from observations of the spectra, polarization, and timing of gamma-rays from active galactic nuclei and gamma-ray bursts. Other sensitive tests are provided by observations of the spectra of ultrahigh energy cosmic rays and neutrinos. Using the latest data from the Pierre Auger Observatory one can already derive an upper limit of 4.5 x 10(exp -23) to the amount of LIV of at a proton Lorentz factor of approximately 2 x 10(exp 11). This result has fundamental implications for quantum gravity models. I will also discuss the possibilities of using more sensitive space based detection techniques to improve searches for LIV in the future.

  6. A proposed modification to the McDonald 2010 criteria for the diagnosis of primary progressive multiple sclerosis.

    LENUS (Irish Health Repository)

    Kelly, S B

    2013-07-01

    The diagnostic criteria for primary-progressive multiple sclerosis (PPMS) have undergone revision over the last 20 years. Cerebrospinal fluid oligoclonal bands (CSFOBs) have received less emphasis in recent revisions of the McDonald criteria. The aim of this study was to examine the sensitivity of the diagnostic criteria for PPMS with particular reference to spinal cord criteria and examine the utility of CSFOBs in a cohort of PPMS patients.

  7. X-ray film calibration

    International Nuclear Information System (INIS)

    Stone, G.F.; Dittmore, C.H.; Henke, B.L.

    1986-01-01

    This paper discusses the use of silver halide x-ray films for imaging and spectroscopy which is limited by the range of intensities that can be recorded and densitometered. Using the manufacturers processing techniques can result in 10 2-3 range in intensity recorded over 0-5 density range. By modifying the chemistry and processing times, ranges of 10 5-6 can be recorded in the same density range. The authors report on x-ray film calibration work and dynamic range improvements. Changes to the processing chemistry and the resulting changes in dynamic range and x-ray sensitivity are discussed

  8. Believability of signals from cosmic ray sources

    International Nuclear Information System (INIS)

    Goodman, M.

    1990-11-01

    This paper discusses some of the criteria by which an observer judges whether to believe a signal or limit that has been reported for a cosmic ray source. The importance of specifying the test before looking at the data is emphasized. 5 refs

  9. Phosphor Scanner For Imaging X-Ray Diffraction

    Science.gov (United States)

    Carter, Daniel C.; Hecht, Diana L.; Witherow, William K.

    1992-01-01

    Improved optoelectronic scanning apparatus generates digitized image of x-ray image recorded in phosphor. Scanning fiber-optic probe supplies laser light stimulating luminescence in areas of phosphor exposed to x rays. Luminescence passes through probe and fiber to integrating sphere and photomultiplier. Sensitivity and resolution exceed previously available scanners. Intended for use in x-ray crystallography, medical radiography, and molecular biology.

  10. High sensitivity MOSFET-based neutron dosimetry

    International Nuclear Information System (INIS)

    Fragopoulou, M.; Konstantakos, V.; Zamani, M.; Siskos, S.; Laopoulos, T.; Sarrabayrouse, G.

    2010-01-01

    A new dosemeter based on a metal-oxide-semiconductor field effect transistor sensitive to both neutrons and gamma radiation was manufactured at LAAS-CNRS Laboratory, Toulouse, France. In order to be used for neutron dosimetry, a thin film of lithium fluoride was deposited on the surface of the gate of the device. The characteristics of the dosemeter, such as the dependence of its response to neutron dose and dose rate, were investigated. The studied dosemeter was very sensitive to gamma rays compared to other dosemeters proposed in the literature. Its response in thermal neutrons was found to be much higher than in fast neutrons and gamma rays.

  11. Volumetry of metastases from renal cell carcinoma. Comparison with the RECIST criteria

    International Nuclear Information System (INIS)

    Graser, A.; Becker, C.R.; Reiser, M.F.; Stief, C.; Staehler, M.

    2008-01-01

    For patients with metastasized renal cell carcinoma (RCC), imaging techniques are of great importance. Currently, therapy widely relies on antiangiogenic factors, which frequently lead to relatively subtle changes in the size of lesions. From this aspect the commonly used RECIST criteria (response evaluation criteria in solid tumors) must be considered as imprecise for the evaluation of the response to therapy. This article gives a review on new software-based volumetric methods, which allow therapy-induced changes in the size of metastases from RCC to be detected with higher sensitivity and reproducibility. A comparison of RECIST and volumetry was carried out with data from patients with metastasized RCC to demonstrate the higher sensitivity of the 3D volumetric procedure. (orig.) [de

  12. Prompt gamma-ray analysis using JRR-3M cold and thermal neutron guide beams

    International Nuclear Information System (INIS)

    Yonezawa, C.; Haji Wood, A.K.; Magara, M.; Hoshi, M.; Tachikawa, E.; Sawahata, H.; Ito, Y.

    1993-01-01

    A permanent and stand-alone neutron-induced prompt gamma-ray analysis (PGA) system, usable at both cold and thermal neutron beam guides of JRR-3M has been constructed. Neutron flux at the sample positions were 1.4x10 8 and 2.4x10 7 n cm -2 s -1 for the cold and thermal neutrons, respectively. The γ-ray spectrometer is equipped to acquire three modes of spectra simultaneously: single mode, Compton suppression mode and pair mode, in an energy range up to 12 MeV. Owing to the cold neutron guide beam and the low γ-ray background system, analytical sensitivities and detection limits better than those in other PGA systems have been achieved. Analytical sensitivity and detection limit for 73 elements were measured. Boron, Gd, Sm and Cd are the most sensitive elements with detection limits down to 1 to 10 ng. For some elements such as F, Al, V, Eu and Hf, decay γ-rays are more sensitive compared to their respective prompt γ-ray. Analytical sensitivity of several heavy elements through detection of characteristic X-rays was higher than that through the prompt γ-ray detection. Analytical applicability of some sensitive elements such as B, H, Gd and Sm were examined. Isotopic analysis of Ni and Si were also examined. (author)

  13. X-ray Microprobe for Fluorescence and Diffraction Analysis

    International Nuclear Information System (INIS)

    Ice, G.E.

    2005-01-01

    X-ray diffraction (see unit 1.1) and x-ray excited fluorescence analysis are powerful techniques for the nondestructive measurement of crystal structure and chemical composition. X-ray fluorescence analysis is inherently nondestructive with orders of magnitude lower power deposited for the same detectable limit as with fluorescence excited by charged particle probes (Sparks, 1980). X-ray diffraction analysis is sensitive to crystal structure with orders-of-magnitude greater sensitivity to crystallographic strain than electron probes (Rebonato, et al. 1989). When a small-area x-ray microbeam is used as the probe, chemical composition (Z>14), crystal structure, crystalline texture, and crystalline strain distributions can be determined. These distributions can be studied both at the surface of the sample and deep within the sample (Fig. 1). Current state-of-the-art can achieve an ∼1 mm-D x-ray microprobe and an ∼0.1 mm-D x-ray microprobe has been demonstrated (Bilderback, et al., 1994). Despite their great chemical and crystallographic sensitivities, x-ray microprobe techniques have until recently been restricted by inefficient x-ray focusing optics and weak x-ray sources; x-ray microbeam analysis was largely superseded by electron techniques in the 50's. However, interest in x-ray microprobe techniques has now been revived (Howells, et al., 1983; Ice and Sparks, 1984; Chevallier, et al., 1997; Riekel 1992; Thompson, el al., 1992; and Making and Using... 1997) by the development of efficient x-ray focusing optics and ultra-high intensity synchrotron x-ray sources (Buras and Tazzari, 1984; Shenoy, et al., 1988). These advances have increased the achievable microbeam flux by more than 11 orders of magnitude (Fig. 2) (Ice, 1997); the flux in a tunable 1 mm-D beam on a 'so called' 3rd-generation synchrotron source such as the APS can exceed the flux in a fixed-energy mm2 beam on a conventional source. These advances make x-ray microfluorescence and x-ray

  14. Use of subjective and objective criteria to categorise visual disability.

    Science.gov (United States)

    Kajla, Garima; Rohatgi, Jolly; Dhaliwal, Upreet

    2014-04-01

    Visual disability is categorised using objective criteria. Subjective measures are not considered. To use subjective criteria along with objective ones to categorise visual disability. Ophthalmology out-patient department; teaching hospital; observational study. Consecutive persons aged >25 years, with vision disability; group-zero: normal range of vision, to group-X: no perception of light, bilaterally. Snellen's vision; binocular contrast sensitivity (Pelli-Robson chart); automated binocular visual field (Humphrey; Esterman test); and vision-related quality of life (Indian Visual Function Questionnaire-33; IND-VFQ33) were recorded. SPSS version-17; Kruskal-wallis test was used to compare contrast sensitivity and visual fields across groups, and Mann-Whitney U test for pair-wise comparison (Bonferroni adjustment; P visual fields were comparable for differing disability grades except when disability was severe (P disability grades but comparable for groups III (78.51 ± 6.86) and IV (82.64 ± 5.80), and groups IV and V (77.23 ± 3.22); these were merged to generate group 345; similarly, global scores were comparable for adjacent groups V and VI (72.53 ± 6.77), VI and VII (74.46 ± 4.32), and VII and VIII (69.12 ± 5.97); these were merged to generate group 5678; thereafter, contrast sensitivity and global and individual IND-VFQ33 scores could differentiate between different grades of disability in the five new groups. Subjective criteria made it possible to objectively reclassify visual disability. Visual disability grades could be redefined to accommodate all from zero-100%.

  15. Idaho National Engineering Laboratory release criteria for decontamination and decommissioning

    International Nuclear Information System (INIS)

    Dolenc, M.R.; Case, M.J.

    1986-01-01

    Criteria have been developed for release of Idaho National Engineering Laboratory (INEL) facilities and land areas following decontamination and decommissioning (D and D). Decommissioning release criteria in the form of dose guidelines were proposed by the US Nuclear Regulatory Commission as early as 1980. These criteria were used on an interim basis for INEL D and D projects. However, dose guidelines alone do not adequately cover the criteria necessary to release sites for unrestricted use. In actual practice, other parameters such as pathways analyses, sampling and instrumentation techniques, and implementation procedures are required to develop the basis for unrestricted release of a site. Thus, a rigorous approach for evaluating these other parameters is needed to develop acceptable D and D release criteria. Because of the complex and sensitive nature of the dose and pathways analyses work, a thorough review by experts in those respective fields was desired. Input and support in preparing or reviewing each part of the criteria development task was solicited from several DOE field offices. Experts were identified and contracted to assist in preparing portions of the release criteria, or to serve on a peer-review committee. Thus, the entire release criteria development task was thoroughly reviewed by recognized experts from each DOE field office, to validate technical content of the INEL site-specific document

  16. Adult "termination-of-resuscitation" (TOR)-criteria may not be suitable for children - a retrospective analysis.

    Science.gov (United States)

    Rotering, Victoria Maria; Trepels-Kottek, Sonja; Heimann, Konrad; Brokmann, Jörg-Christian; Orlikowsky, Thorsten; Schoberer, Mark

    2016-12-07

    Only a small number of patients survive out-of-hospital-cardiac-arrest (OHCA). The duration of CPR varies considerably and transportation of patients under CPR is often unsuccessful. Termination-of-resuscitation (TOR)-criteria aim to preclude futile resuscitation efforts. Our goal was to find out to which extent existing TOR-criteria can be transferred to paediatric OHCA-patients with special regard to their prognostic value. We performed a retrospective analysis of an eleven-year single centre patient cohort. 43 paediatric patients admitted to our institution after emergency-medical-system (EMS)-confirmed OHCA from 2003 to 2013 were included. Morrison's BLS- and ALS-TOR-rules as well as the Trauma-TOR-criteria by the American Association of EMS Physicians were evaluated for application in children, by calculating sensitivity, specificity, negative and positive predictive value for death-, as well as survival-prediction in our cohort. 26 patients achieved ROSC and 14 were discharged alive (n = 7 PCPC 1/2, n = 7 PCPC 5). Sensitivity for BLS-TOR-criteria predicting death was 48.3%, specificity 92.9%, the PPV 93.3% and the NPV 46.4%. ALS-TOR-criteria for death had a sensitivity of 10.3%, specificity of 100%, a PPV of 100% and an NPV of 35%. Retrospective application of the BLS-TOR-rule in our patient cohort identified the resuscitation of one later survivor as futile. ALS-TOR-criteria did not give false predictions of death. The proportion of CPRs that could have been abandoned is 48.2% for the BLS-TOR and only 10.3% for the ALS-TOR-rule. Both rules therefore appear not to be transferable to a paediatric population.

  17. X-rays from supernova 1987A

    International Nuclear Information System (INIS)

    Xu, Y.; Sutherland, P.; Mccray, R.; Ross, R.R.

    1988-01-01

    Detailed calculations of the development of the X-ray spectrum of 1987A are presented using more realistic models for the supernova composition and density structure provided by Woosley. It is shown how the emergence of the X-ray spectrum depends on the parameters of the model and the nature of its central energy source. It is shown that the soft X-ray spectrum should be dominated by a 6.4 keV Fe K(alpha) emission line that could be observed by a sensitive X-ray telescope. 28 references

  18. Half-body x-ray suppresses the acquisition of delayed-type hypersensitivity in the mouse

    Energy Technology Data Exchange (ETDEWEB)

    Maguire, Jr, H C

    1979-01-01

    800 R half-body x-ray suppressed the acquisition of allergic contact dermatitis in mice (1) if the x-ray field included the lymph nodes regional to the sensitization site, and (2) when x-ray was given during, but not immediately before, induction of the sensitivity.

  19. Diagnosis of Tuberculosis Following World Health Organization–Recommended Criteria in Severely Malnourished Children Presenting With Pneumonia

    Science.gov (United States)

    Chisti, Mohammod Jobayer; Salam, Mohammed Abdus; Shahid, Abu S. M. S. B.; Shahunja, K. M.; Das, Sumon Kumar; Faruque, Abu Syed Golam; Bardhan, Pradip Kumar; Ahmed, Tahmeed

    2017-01-01

    Evidences on diagnosis of tuberculosis (TB) following the World Health Organization (WHO) criteria in children with severe acute malnutrition (SAM) are lacking. We sought to evaluate the WHO criteria for the diagnosis of TB in such children. In this prospective study, we enrolled SAM children aged <5 with radiological pneumonia. We collected induced sputum and gastric lavage for smear microscopy, mycobacterial culture, and Xpert MTB/RIF. Using the last 2 methods as the gold standard, we determined sensitivity, specificity, and positive and negative predictive values of WHO criteria (n = 388). However, Xpert MTB/RIF was performed on the last 214 children. Compared to mycobacterial culture–confirmed TB, sensitivity and specificity (95% confidence interval) of WHO criteria were 40 (14% to 73%) and 84 (80% to 87%), respectively. Compared to culture- and/or Xpert MTB/RIF-confirmed TB, the values were 22% (9% to 43%) and 83 (79% to 87%), respectively. Thus, the good specificity of the WHO criteria may help minimize overtreatment with anti-TB therapy in SAM children, especially in resource-limited settings. PMID:28229100

  20. Diagnosis of Tuberculosis Following World Health Organization–Recommended Criteria in Severely Malnourished Children Presenting With Pneumonia

    Directory of Open Access Journals (Sweden)

    Mohammod Jobayer Chisti MBBS, MMed, PhD

    2017-01-01

    Full Text Available Evidences on diagnosis of tuberculosis (TB following the World Health Organization (WHO criteria in children with severe acute malnutrition (SAM are lacking. We sought to evaluate the WHO criteria for the diagnosis of TB in such children. In this prospective study, we enrolled SAM children aged <5 with radiological pneumonia. We collected induced sputum and gastric lavage for smear microscopy, mycobacterial culture, and Xpert MTB/RIF. Using the last 2 methods as the gold standard, we determined sensitivity, specificity, and positive and negative predictive values of WHO criteria (n = 388. However, Xpert MTB/RIF was performed on the last 214 children. Compared to mycobacterial culture–confirmed TB, sensitivity and specificity (95% confidence interval of WHO criteria were 40 (14% to 73% and 84 (80% to 87%, respectively. Compared to culture- and/or Xpert MTB/RIF-confirmed TB, the values were 22% (9% to 43% and 83 (79% to 87%, respectively. Thus, the good specificity of the WHO criteria may help minimize overtreatment with anti-TB therapy in SAM children, especially in resource-limited settings.

  1. Diagnosis of Tuberculosis Following World Health Organization-Recommended Criteria in Severely Malnourished Children Presenting With Pneumonia.

    Science.gov (United States)

    Chisti, Mohammod Jobayer; Salam, Mohammed Abdus; Shahid, Abu S M S B; Shahunja, K M; Das, Sumon Kumar; Faruque, Abu Syed Golam; Bardhan, Pradip Kumar; Ahmed, Tahmeed

    2017-01-01

    Evidences on diagnosis of tuberculosis (TB) following the World Health Organization (WHO) criteria in children with severe acute malnutrition (SAM) are lacking. We sought to evaluate the WHO criteria for the diagnosis of TB in such children. In this prospective study, we enrolled SAM children aged <5 with radiological pneumonia. We collected induced sputum and gastric lavage for smear microscopy, mycobacterial culture, and Xpert MTB/RIF. Using the last 2 methods as the gold standard, we determined sensitivity, specificity, and positive and negative predictive values of WHO criteria (n = 388). However, Xpert MTB/RIF was performed on the last 214 children. Compared to mycobacterial culture-confirmed TB, sensitivity and specificity (95% confidence interval) of WHO criteria were 40 (14% to 73%) and 84 (80% to 87%), respectively. Compared to culture- and/or Xpert MTB/RIF-confirmed TB, the values were 22% (9% to 43%) and 83 (79% to 87%), respectively. Thus, the good specificity of the WHO criteria may help minimize overtreatment with anti-TB therapy in SAM children, especially in resource-limited settings.

  2. Caffeine sensitive repair and mutation induction in UV- or γ-ray-irradiated Dictyostelium discoideum

    International Nuclear Information System (INIS)

    Kanishi, Nobuji; Kinjo, Yasuhito; Watanabe, Makoto.

    1990-01-01

    It seems that certain kinds of chemical substances increase the distortion in molecules, change the high order microstructures of nuclei and chromosomes, and exert large variation to the function of repairing the damage of genes due to radiation and others, by coupling with DNA, protein or enzyme system. It has been well known that caffeine is one of such compounds, and by coupling with DNA, it increases the damage due to ultraviolet ray and gives the action of obstructing repair in addition to the action of inducing the abnormality of chromosomes and mutation. Dictyostelium discoideum has the simplest nuclear structure, and shows extremely high resistance to radiation by its high restoration ability. The authors have advanced the research by paying attention to its characteristics, and comparing the Dictyostelium discoideum as one model system with the lymphocyte system of higher animals. This time, the authors analyzed the characteristics of two kinds of sensitivity repair process of caffeine, and investigated into their relation with the occurrence of mutation. The experimental method and the results are reported. (K.I.)

  3. Caffeine sensitive repair and mutation induction in UV- or. gamma. -ray-irradiated Dictyostelium discoideum

    Energy Technology Data Exchange (ETDEWEB)

    Kanishi, Nobuji (Tokyo Metropolitan Research Lab. of Public Health (Japan)); Kinjo, Yasuhito; Watanabe, Makoto

    1990-01-01

    It seems that certain kinds of chemical substances increase the distortion in molecules, change the high order microstructures of nuclei and chromosomes, and exert large variation to the function of repairing the damage of genes due to radiation and others, by coupling with DNA, protein or enzyme system. It has been well known that caffeine is one of such compounds, and by coupling with DNA, it increases the damage due to ultraviolet ray and gives the action of obstructing repair in addition to the action of inducing the abnormality of chromosomes and mutation. Dictyostelium discoideum has the simplest nuclear structure, and shows extremely high resistance to radiation by its high restoration ability. The authors have advanced the research by paying attention to its characteristics, and comparing the Dictyostelium discoideum as one model system with the lymphocyte system of higher animals. This time, the authors analyzed the characteristics of two kinds of sensitivity repair process of caffeine, and investigated into their relation with the occurrence of mutation. The experimental method and the results are reported. (K.I.).

  4. Code of safe practice for the use of x-rays in dentistry

    International Nuclear Information System (INIS)

    1991-06-01

    The purpose of this Code of Safe Practice for the Use of X-rays in Dentistry is to provide criteria for working procedures, x-ray equipment and protective materials necessary for the use of x-rays in dental diagnosis according to currently accepted standards of safety. Conformity with this code may be taken as a primary indication of compliance with radiation protection legislation. 7 refs., 1 ill

  5. The Advanced Gamma-ray Imaging System (AGIS): Simulation Studies

    Science.gov (United States)

    Fegan, Stephen; Buckley, J. H.; Bugaev, S.; Funk, S.; Konopelko, A.; Maier, G.; Vassiliev, V. V.; Simulation Studies Working Group; AGIS Collaboration

    2008-03-01

    The Advanced Gamma-ray Imaging System (AGIS) is a concept for the next generation instrument in ground-based very high energy gamma-ray astronomy. It has the goal of achieving significant improvement in sensitivity over current experiments. We present the results of simulation studies of various possible designs for AGIS. The primary characteristics of the array performance, collecting area, angular resolution, background rejection, and sensitivity are discussed.

  6. Ray trajectories for Alcubierre spacetime

    International Nuclear Information System (INIS)

    Anderson, Tom H; Mackay, Tom G; Lakhtakia, Akhlesh

    2011-01-01

    The Alcubierre spacetime was simulated by means of a Tamm medium which is asymptotically identical to vacuum and has constitutive parameters which are continuous functions of the spatial coordinates. Accordingly, the Tamm medium is amenable to physical realization as a micro- or nanostructured metamaterial. A comprehensive characterization of ray trajectories in the Tamm medium was undertaken, within the geometric-optics regime. Propagation directions corresponding to evanescent waves were identified: these occur in the region of the Tamm medium which corresponds to the warp bubble of the Alcubierre spacetime, especially for directions perpendicular to the velocity of the warp bubble at high speeds of that bubble. Ray trajectories are acutely sensitive to the magnitude and direction of the warp bubble's velocity, but rather less sensitive to the thickness of the transition zone between the warp bubble and its background. In particular, for rays which travel in the same direction as the warp bubble, the latter acts as a focusing lens, most notably at high speeds

  7. Probing the Cosmic X-Ray and MeV Gamma-Ray Background Radiation through the Anisotropy

    Energy Technology Data Exchange (ETDEWEB)

    Inoue, Yoshiyuki [Stanford Univ., CA (United States). Kavli Inst. for Particle Astrophysics and Cosmology; SLAC National Accelerator Lab., Menlo Park, CA (United States); Murase, Kohta [Inst. for Advanced Study, Princeton, NJ (United States). School of Natural Sciences; Madejski, Grzegorz M. [Stanford Univ., CA (United States). Kavli Inst. for Particle Astrophysics and Cosmology; SLAC National Accelerator Lab., Menlo Park, CA (United States); Uchiyama, Yasunobu [Stanford Univ., CA (United States). Kavli Inst. for Particle Astrophysics and Cosmology; SLAC National Accelerator Lab., Menlo Park, CA (United States); Rikkyo Univ., Tokyo (Japan). Dept. of Physics

    2013-09-24

    While the cosmic soft X-ray background is very likely to originate from individual Seyfert galaxies, the origin of the cosmic hard X-ray and MeV gamma-ray background is not fully understood. It is expected that Seyferts including Compton thick population may explain the cosmic hard X-ray background. At MeV energy range, Seyferts having non-thermal electrons in coronae above accretion disks or MeV blazars may explain the background radiation. We propose that future measurements of the angular power spectra of anisotropy of the cosmic X-ray and MeV gamma-ray backgrounds will be key to deciphering these backgrounds and the evolution of active galactic nuclei (AGNs). As AGNs trace the cosmic large-scale structure, spatial clustering of AGNs exists. We show that e-ROSITA will clearly detect the correlation signal of unresolved Seyferts at 0.5-2 keV and 2-10 keV bands and will be able to measure the bias parameter of AGNs at both bands. Once the future hard X-ray all sky satellites achieve the sensitivity better than 10-12 erg/cm2/s-1 at 10-30 keV or 30-50 keV - although this is beyond the sensitivities of current hard X-ray all sky monitors - angular power spectra will allow us to independently investigate the fraction of Compton-thick AGNs in all Seyferts. We also find that the expected angular power spectra of Seyferts and blazars in the MeV range are different by about an order of magnitude, where the Poisson term, so-called shot noise, is dominant. Current and future MeV instruments will clearly disentangle the origin of the MeV gamma-ray background through the angular power spectrum.

  8. Probing the cosmic x-ray and MeV gamma ray background radiation through the anisotropy

    Energy Technology Data Exchange (ETDEWEB)

    Inoue, Yoshiyuki [Stanford Univ., CA (United States); Murase, Kohta [Inst. for Advanced Study, Princeton, NJ (United States); Madejski, Grzegorz M. [Stanford Univ., CA (United States); Uchiyama, Yasunobu [Stanford Univ., CA (United States); Rikkyo Univ., Tokyo (Japan)

    2013-09-24

    While the cosmic soft X-ray background is very likely to originate from individual Seyfert galaxies, the origin of the cosmic hard X-ray and MeV gamma-ray background is not fully understood. It is expected that Seyferts including Compton thick population may explain the cosmic hard X-ray background. At MeV energy range, Seyferts having non-thermal electrons in coronae above accretion disks or MeV blazars may explain the background radiation. We propose that future measurements of the angular power spectra of anisotropy of the cosmic X-ray and MeV gamma-ray backgrounds will be key to deciphering these backgrounds and the evolution of active galactic nuclei (AGNs). As AGNs trace the cosmic large-scale structure, spatial clustering of AGNs exists. We show that e-ROSITA will clearly detect the correlation signal of unresolved Seyferts at 0.5-2 keV and 2-10 keV bands and will be able to measure the bias parameter of AGNs at both bands. Once future hard X-ray all sky satellites achieve a sensitivity better than 10–12 erg cm–2 s–1 at 10-30 keV or 30-50 keV—although this is beyond the sensitivities of current hard X-ray all sky monitors—angular power spectra will allow us to independently investigate the fraction of Compton-thick AGNs in all Seyferts. We also find that the expected angular power spectra of Seyferts and blazars in the MeV range are different by about an order of magnitude, where the Poisson term, so-called shot noise, is dominant. Current and future MeV instruments will clearly disentangle the origin of the MeV gamma-ray background through the angular power spectrum.

  9. Isolation and characterization of MMS-sensitive mutants of Saccharomyces cerevisiae

    International Nuclear Information System (INIS)

    Prakash, L.; Prakash, S.

    1977-01-01

    We have isolated mutants sensitive to methyl methanesulfonate (MMS) in Saccharomyces cerevisiae. Alleles of rad1, rad4, rad6, rad52, rad55 and rad57 were found among these mms mutants. Twenty-nine of the mms mutants which complement the existing radiation-sensitive (rad and rev) mutants belong to 22 new complementation groups. Mutants from five complementation groups are sensitive only to MMS. Mutants of 11 complementation groups are sensitive to uv or x rays in addition to MMS, mutants of six complementation groups are sensitive to all three agents. The cross-sensitivities of these mms mutants to uv and x rays are discussed in terms of their possible involvement in DNA repair. Sporulation is reduced or absent in homozygous diploids of mms mutants from nine complementation groups

  10. Applicability and agreement of different diagnostic criteria for sarcopenia estimation in the elderly.

    Science.gov (United States)

    Pagotto, Valéria; Silveira, Erika Aparecida

    2014-01-01

    The purpose of this study cross-sectional study comprising 132 community dwelling elderly (≥ 60 years) was to identify sarcopenia prevalence in the Brazilian elderly, utilizing different diagnostic criteria and analyze agreement between criteria. Sarcopenia was assessed by nine muscle mass diagnostic criteria, by two muscle strength criteria and also by the combination of criteria. Prevalence was analyzed for each method, along with differences by gender and age group through calculation of the prevalence ratio (PR) and confidence interval (CI) 95%. The Kappa coefficient was used to analyze the level of agreement between all criteria. Sarcopenia prevalence varied between 60.6% and 8.3% with the application of muscle mass criteria, and between 54.2% and 48.8% with the application of strength criteria. The combination muscle mass+strength resulted in a decrease of prevalence in all criteria, varying between 36.6% and 6.1%. There was an increase in prevalence according to age groups for all methods. Prevalence was higher for men according to three muscle mass criteria, and higher in women for strength criteria and by two combined mass+strength criteria. The best level of agreement was obtained for two methods that utilized dual energy X-ray absorptiometry (DXA). The prevalence of sarcopenia differs by gender and age and definition criteria. The low agreement levels obtained between methods and the different prevalence values encountered indicate the necessities of an operational definition for the estimation of sarcopenia in different population. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  11. Flat Field Anomalies in an X-Ray CCD Camera Measured Using a Manson X-Ray Source

    International Nuclear Information System (INIS)

    Michael Haugh

    2008-01-01

    The Static X-ray Imager (SXI) is a diagnostic used at the National Ignition Facility (NIF) to measure the position of the X-rays produced by lasers hitting a gold foil target. It determines how accurately NIF can point the laser beams and is critical to proper NIF operation. Imagers are located at the top and the bottom of the NIF target chamber. The CCD chip is an X-ray sensitive silicon sensor, with a large format array (2k x 2k), 24 (micro)m square pixels, and 15 (micro)m thick. A multi-anode Manson X-ray source, operating up to 10kV and 2mA, was used to characterize and calibrate the imagers. The output beam is heavily filtered to narrow the spectral beam width, giving a typical resolution E/ΔE ∼ 12. The X-ray beam intensity was measured using an absolute photodiode that has accuracy better than 1% up to the Si K edge and better than 5% at higher energies. The X-ray beam provides full CCD illumination and is flat, within ±1.5% maximum to minimum. The spectral efficiency was measured at 10 energy bands ranging from 930 eV to 8470 eV. The efficiency pattern follows the properties of Si. The maximum quantum efficiency is 0.71. We observed an energy dependent pixel sensitivity variation that showed continuous change over a large portion of the CCD. The maximum sensitivity variation was >8% at 8470 eV. The geometric pattern did not change at lower energies, but the maximum contrast decreased and was less than the measurement uncertainty below 4 keV. We were also able to observe debris on the CCD chip. The debris showed maximum contrast at the lowest energy used, 930 eV, and disappeared by 4 keV. The Manson source is a powerful tool for characterizing the imaging errors of an X-ray CCD imager. These errors are quite different from those found in a visible CCD imager

  12. Preliminary investigation of the NMR, optical and x-ray CT dose-response of polymer gel dosimeters incorporating cosolvents to improve dose sensitivity

    Energy Technology Data Exchange (ETDEWEB)

    Koeva, V I; McAuley, K B [Department of Chemical Engineering, Queen' s University, Kingston, ON, K7L 3N6 (Canada); Olding, T [Department of Physics, Queen' s University, Kingston, ON, K7L 3N6 (Canada); Jirasek, A [Department of Physics and Astronomy, University of Victoria, Victoria, BC, V8W 3P6 (Canada); Schreiner, L J [Cancer Centre of Southeastern Ontario, Kingston, ON, K7L5P9 (Canada)], E-mail: kim.mcauley@chee.queensu.ca

    2009-05-07

    This study reports on efforts to increase the dose sensitivity of polymer gel dosimeters used in 3D radiation dosimetry. The potential of several different cosolvents is investigated, with the aim of increasing the solubility of N,N'-methylene-bisacrylamide crosslinker in polymer gel dosimeters. Glycerol and isopropanol increase the limit for the crosslinker solubility from approximately 3% to 5% and 10% by weight, respectively. This enables the manufacture of polymer gel dosimeters with much higher levels of crosslinking than was previously possible. New dosimeter recipes containing up to 5 wt% N,N'-methylene-bisacrylamide were subjected to spatially uniform radiation and were studied using nuclear magnetic resonance (NMR), as well as x-ray and optical CT techniques. The resulting dosimeters exhibit dose sensitivities that are up to 2.7 times higher than measured for a typical dosimeters with 3% N,N'-methylene-bisacrylamide without the addition of cosolvent. Two additional cosolvents (n-propanol and sec-butanol) were deemed unsuitable for practical dosimeters due to incompatibility with gelatin, cloudiness prior to irradiation, and immiscibility with water when large quantities of cosolvent were used. The dosimeters with high N,N'-methylene-bisacrylamide content that used isopropanol or glycerol as cosolvents had high optical clarity prior to irradiation, but did not produce suitable optical CT results for non-uniformly irradiated gels due to polymer development outside of the high dose regions of the pencil beams and significant light scatter. Further experiments are required to determine whether cosolvents can be used to manufacture gels with sufficiently high dose sensitivity for readout using x-ray computed tomography.

  13. Field-based optimal-design of an electric motor: a new sensitivity formulation

    Science.gov (United States)

    Barba, Paolo Di; Mognaschi, Maria Evelina; Lowther, David Alister; Wiak, Sławomir

    2017-12-01

    In this paper, a new approach to robust optimal design is proposed. The idea is to consider the sensitivity by means of two auxiliary criteria A and D, related to the magnitude and isotropy of the sensitivity, respectively. The optimal design of a switched-reluctance motor is considered as a case study: since the case study exhibits two design criteria, the relevant Pareto front is approximated by means of evolutionary computing.

  14. Optoelectronic Picosecond Detection of Synchrotron X-rays

    Energy Technology Data Exchange (ETDEWEB)

    Durbin, Stephen M. [Purdue Univ., West Lafayette, IN (United States)

    2017-08-04

    The goal of this research program was to develop a detector that would measure x-ray time profiles with picosecond resolution. This was specifically aimed for use at x-ray synchrotrons, where x-ray pulse profiles have Gaussian time spreads of 50-100 ps (FWHM), so the successful development of such a detector with picosecond resolution would permit x-ray synchrotron studies to break through the pulse width barrier. That is, synchrotron time-resolved studies are currently limited to pump-probe studies that cannot reveal dynamics faster than ~50 ps, whereas the proposed detector would push this into the physically important 1 ps domain. The results of this research effort, described in detail below, are twofold: 1) the original plan to rely on converting electronic signals from a semiconductor sensor into an optical signal proved to be insufficient for generating signals with the necessary time resolution and sensitivity to be widely applicable; and 2) an all-optical method was discovered whereby the x-rays are directly absorbed in an optoelectronic material, lithium tantalate, which can then be probed by laser pulses with the desired picosecond sensitivity for detection of synchrotron x-rays. This research program has also produced new fundamental understanding of the interaction of x-rays and optical lasers in materials that has now created a viable path for true picosecond detection of synchrotron x-rays.

  15. Viability of exploiting L-shell fluorescence for X-ray polarimetry

    Energy Technology Data Exchange (ETDEWEB)

    Weisskopf, M C; Elsner, R F; Ramsey, B D [National Aeronautics and Space Administration, Huntsville, AL (USA). Space Sciences Lab.; Sutherland, P G [McMaster Univ., Hamilton, Ontario (Canada). Dept. of Physics

    1985-05-15

    It has been suggested that one may build an X-ray polarimeter by exploiting the polarization dependence of the angular distribution of L-shell fluorescence photons. In this paper we examine, theoretically, the sensitivity of this approach to polarimetry. We apply our calculations to several detection schemes using imaging proportional counters that would have direct application in X-ray astronomy. We find, however, that the sensitivity of this method for measuring X-ray polarization is too low to be of use for other than laboratory applications.

  16. An index with improved diagnostic accuracy for the diagnosis of Crohn's disease derived from the Lennard-Jones criteria.

    Science.gov (United States)

    Reinisch, S; Schweiger, K; Pablik, E; Collet-Fenetrier, B; Peyrin-Biroulet, L; Alfaro, I; Panés, J; Moayyedi, P; Reinisch, W

    2016-09-01

    The Lennard-Jones criteria are considered the gold standard for diagnosing Crohn's disease (CD) and include the items granuloma, macroscopic discontinuity, transmural inflammation, fibrosis, lymphoid aggregates and discontinuous inflammation on histology. The criteria have never been subjected to a formal validation process. To develop a validated and improved diagnostic index based on the items of Lennard-Jones criteria. Included were 328 adult patients with long-standing CD (median disease duration 10 years) from three centres and classified as 'established', 'probable' or 'non-CD' by Lennard-Jones criteria at time of diagnosis. Controls were patients with ulcerative colitis (n = 170). The performance of each of the six diagnostic items of Lennard-Jones criteria was modelled by logistic regression and a new index based on stepwise backward selection and cut-offs was developed. The diagnostic value of the new index was analysed by comparing sensitivity, specificity and accuracy vs. Lennard-Jones criteria. By Lennard-Jones criteria 49% (n = 162) of CD patients would have been diagnosed as 'non-CD' at time of diagnosis (sensitivity/specificity/accuracy, 'established' CD: 0.34/0.99/0.67; 'probable' CD: 0.51/0.95/0.73). A new index was derived from granuloma, fibrosis, transmural inflammation and macroscopic discontinuity, but excluded lymphoid aggregates and discontinuous inflammation on histology. Our index provided improved diagnostic accuracy for 'established' and 'probable' CD (sensitivity/specificity/accuracy, 'established' CD: 0.45/1/0.72; 'probable' CD: 0.8/0.85/0.82), including the subgroup isolated colonic CD ('probable' CD, new index: 0.73/0.85/0.79; Lennard-Jones criteria: 0.43/0.95/0.69). We developed an index based on items of Lennard-Jones criteria providing improved diagnostic accuracy for the differential diagnosis between CD and UC. © 2016 John Wiley & Sons Ltd.

  17. Proton induced X-ray emission analysis

    International Nuclear Information System (INIS)

    Khan, Rashiduzzman

    1976-09-01

    The developments in proton induced X-ray emission analysis are reviewed. Techniques for analyzing thick and thin samples of different origin are described. Discussions on the application of proton induced X-ray emission analysis in different fields, comparison of the sensitivity of this method with other analytical techniques, its limitations and possible improvements are presented

  18. Evolving interpretation of the athlete's electrocardiogram: from European Society of Cardiology and Stanford criteria, to Seattle criteria and beyond.

    Science.gov (United States)

    Zorzi, Alessandro; ElMaghawry, Mohamed; Corrado, Domenico

    2015-01-01

    Electrocardiographic (ECG) pre-participation screening can prevent sudden cardiac death in the athletes by early diagnosis and disqualification of affected individuals. Interpretation of the athlete's ECG should be based on specific criteria, because ECG changes that would be considered abnormal in the untrained population may develop in trained athletes as a physiologic and benign consequence of the heart's adaptation to exercise. In 2010, a stem document from the Section of Sports Cardiology of the European Society of Cardiology (ESC) proposed to classify the athlete's ECG changes according to the prevalence, relation to exercise training, association with an increased risk of cardiovascular disease and need for further investigations into two groups: "common and training-related" (Group 1) and "uncommon and training-unrelated" (Group 2). Over the last years, several efforts have been made to refine the ESC criteria for interpretation of the athlete's ECG in order to improve specificity maintaining good sensitivity, especially among elite and Afro-Caribbean athletes, which show the highest rate of false positives Group 2 ECG abnormalities. However, the balance between improvement in specificity and loss of sensitivity should be evaluated keeping in mind that the primary aim of the screening program is to save the athlete's lives rather than money. Copyright © 2015 Elsevier Inc. All rights reserved.

  19. Pragmatic criteria of the definition of neonatal near miss: a comparative study.

    Science.gov (United States)

    Kale, Pauline Lorena; Jorge, Maria Helena Prado de Mello; Laurenti, Ruy; Fonseca, Sandra Costa; Silva, Kátia Silveira da

    2017-12-04

    The objective of this study was to test the validity of the pragmatic criteria of the definitions of neonatal near miss, extending them throughout the infant period, and to estimate the indicators of perinatal care in public maternity hospitals. A cohort of live births from six maternity hospitals in the municipalities of São Paulo, Niterói, and Rio de Janeiro, Brazil, was carried out in 2011. We carried out interviews and checked prenatal cards and medical records. We compared the pragmatic criteria (birth weight, gestational age, and 5' Apgar score) of the definitions of near miss of Pileggi et al., Pileggi-Castro et al., Souza et al., and Silva et al. We calculated sensitivity, specificity (gold standard: infant mortality), percentage of deaths among newborns with life-threatening conditions, and rates of near miss, mortality, and severe outcomes per 1,000 live births. A total 7,315 newborns were analyzed (completeness of information > 99%). The sensitivity of the definition of Pileggi-Castro et al. was higher, resulting in a higher number of cases of near miss, Souza et al. presented lower value, and Pileggi et al. and de Silva et al. presented intermediate values. There is an increase in sensitivity when the period goes from 0-6 to 0-27 days, and there is a decrease when it goes to 0-364 days. Specificities were high (≥ 97%) and above sensitivities (54% to 77%). One maternity hospital in São Paulo and one in Niterói presented, respectively, the lowest and highest rates of infant mortality, near miss, and frequency of births with life-threatening conditions, regardless of the definition. The definitions of near miss based exclusively on pragmatic criteria are valid and can be used for monitoring purposes. Based on the perinatal literature, the cutoff points adopted by Silva et al. were more appropriate. Periodic studies could apply a more complete definition, incorporating clinical, laboratory, and management criteria, including congenital anomalies

  20. Clinical Diagnosis of Achalasia: How Reliable is the Barium X-Ray?

    Directory of Open Access Journals (Sweden)

    I El-Takli

    2006-01-01

    Full Text Available Manometry is considered to be the gold standard for the diagnosis of achalasia. However, many physicians believe that contrast radiography, classically showing esophageal dilation with bird-beak narrowing of the gastroesophageal junction, is also accurate in either diagnosing or excluding the disorder. The aim of the current study was to determine the accuracy of barium x-ray in the diagnosis of achalasia. The radiological diagnosis of all patients manometrically diagnosed with achalasia (using conventional criteria between January 1994 and June 1998 were reviewed. A total of 51 cases of achalasia were identified. Thirteen patients were excluded because they either did not have contrast radiography before a manometric diagnosis or had their x-rays performed more than six months previously. Of the remaining 38 patients, achalasia was stated as a diagnostic possibility in the radiologists report in only 22 (58% of those patients. Achalasia was not considered in the remaining 16 patients: two were reported as normal, four as having stenosis/narrowing in distal esophagus, two as having presbyesophagus, one as having mild gastroesophageal reflux and seven as having nonspecific dysmotility. To determine the reason for the diagnostic failure of the barium x-ray, an expert gastrointestinal radiologist reviewed 12 of the nondiagnostic x-rays in a blinded fashion, interspersed with 10 randomly selected esophageal-contrast radiographs from control subjects to avoid bias. Of these initially nondiagnostic x-rays in achalasia patients, typical radiological features of achalasia were deemed to be present in 50%. The present study indicates that contrast radiography lacks sensitivity in the diagnosis of achalasia. This is not only due to radiologist oversight but also because of the absence of the characteristic radiological features in many cases. This reinforces the important role of esophageal manometry in patients with persistent nonstructural dysphagia.

  1. Development of responder criteria for multicomponent non-pharmacological treatment in fibromyalgia

    NARCIS (Netherlands)

    Vervoort, V.M.; Vriezekolk, J.E.; Ende, C.H.M. van den

    2017-01-01

    OBJECTIVES: There is a need to identify individual treatment success in patients with fibromyalgia (FM) who received non-pharmacological treatment. The present study described responder criteria for multicomponent non-pharmacological treatment in FM, and estimated and compared their sensitivity and

  2. Roentgenological criteria od assessment of stages of hydronephrosis in children

    International Nuclear Information System (INIS)

    Pavlova, M.K.

    1988-01-01

    A new parenchymatous index was proposed in order to raise the resolving power of excretory urography, and 3 stages of hydronephrosis were defined on the basis of quantitative indices. X-ray criteria were defined to prevent surgery in a group of children with the initial stage of disease. A group of patients with the terminal stage of hydronephrosis was subdivided into 2 groups: 1) sparing operation, 2) nephrectomy

  3. TAS-116, a novel Hsp90 inhibitor, selectively enhances radio-sensitivity of human cancer cells to X-rays and carbon ion radiation

    Science.gov (United States)

    Lee, Younghyun; Sunada, Shigeaki; Hirakawa, Hirokazu; Fujimori, Akira; Nickoloff, Jac A.; Okayasu, Ryuichi

    2016-01-01

    Hsp90 inhibitors have been investigated as cancer therapeutics in mono-therapy and to augment radiotherapy, however serious adverse effects of early generation Hsp90 inhibitors limited their development. TAS-116 is a novel Hsp90 inhibitor with lower adverse effects than other Hsp90 inhibitors, and here we investigated the radio-sensitizing effects of TAS-116 in low LET X-ray, and high LET carbon ion irradiated human cancer cells and mouse tumor xenografts. TAS-116 decreased cell survival of both X-ray and carbon ion-irradiated human cancer cell lines (HeLa and H1299 cells), and similar to other Hsp90 inhibitors, it did not affect radiosensitivity of non-cancerous human fibroblasts. TAS-116 increased the number of radiation-induced γ-H2AX foci, and delayed the repair of DNA double-strand breaks (DSBs). TAS-116 reduced the expression of proteins that mediate repair of DSBs by homologous recombination (RAD51) and non-homologous end joining (Ku, DNA-PKcs), and suppressed formation of RAD51 foci and phosphorylation/activation of DNA-PKcs. TAS-116 also decreased expression of the cdc25 cell cycle progression marker, markedly increasing G2/M arrest. Combined treatment of mouse tumor xenografts with carbon ions and TAS-116 showed promising delay in tumor growth compared to either individual treatment. These results demonstrate that TAS-116 radio-sensitizes human cancer cells to both X rays and carbon ions by inhibiting the two major DSB repair pathways, and these effects were accompanied by marked cell cycle arrest. The promising results of combination TAS-116 + carbon ion radiation therapy of tumor xenografts justify further exploration of TAS-116 as an adjunct to radiotherapy using low or high LET radiation. PMID:28062703

  4. Sensitivity and Specificity of Proposed DSM-5 Criteria for Autism Spectrum Disorder in Toddlers

    Science.gov (United States)

    Barton, Marianne L.; Robins, Diana L.; Jashar, Dasal; Brennan, Laura; Fein, Deborah

    2013-01-01

    Autism spectrum disorder (ASD) diagnosis is based on behavioral presentation; changes in conceptual models or defining behaviors may significantly impact diagnosis and uptake of ASD-specific interventions. The literature examining impact of DSM-5 criteria is equivocal. Toddlers may be especially vulnerable to the stringent requirements of…

  5. Mutual control of X-rays and nuclear transitions

    Energy Technology Data Exchange (ETDEWEB)

    Gunst, Jonas Friedrich

    2015-12-14

    In the course of this Thesis the mutual control between X-rays and nuclear transitions is investigated theoretically. In the first Part, we study the nuclear photoexcitation with the highly brilliant and coherent X-ray free-electron lasers (XFELs). Apart from amplifying the direct resonant interaction with nuclear transitions, the super-intense XFEL can produce new states of matter like cold, high-density plasmas where secondary nuclear excitation channels may come into play, e.g., nuclear excitation by electron capture (NEEC). Our results predict that in the case of {sup 57}Fe targets secondary NEEC can be safely neglected, whereas it is surprisingly the dominating contribution (in comparison to the direct photoexcitation) for the XFEL-induced {sup 93m}Mo isomer triggering. Based on these case studies, we elaborate a general set of criteria to identify the prevailing excitation channel for a certain nuclear isotope. These criteria may be most relevant for future nuclear resonance experiments at XFEL facilities. On the opposite frontier, the interplay between single X-ray photons and nuclear transitions offer potential storage and processing applications for information science in their most compact form. In the second Part of this Thesis, we show that nuclear forward scattering off {sup 57}Fe targets can be employed to process polarization-encoded single X-rays via timed magnetic field rotations. Apart from the realization of logical gates with X-rays, the polarization encoding is used to design an X-ray quantum eraser scheme where the interference between scattering paths can be switched off and on in a controlled manner. Such setups may advance time-energy complementarity tests to so far unexplored parameter regimes, e.g., to the domain of X-ray quanta.

  6. Soft X-ray radio-sensitivities of pollens in several fruit species

    International Nuclear Information System (INIS)

    Hu Chungen; Deng Xiuxin

    1996-01-01

    Irradiated with different dosages of soft X-ray, pollen germinations of prunus baimang, pear kieffer, trifoliate orange and pummelo, were investigated immediately or several days later after irradiation. The results revealed that the pollens of these fruit tress had different sensitivites to soft X-ray and various responses to storage duration. Therefore, even to the same kind of pollen, irradiation with different optimal exposure doses, as well as pollination at different times during storage, should be adopted variously according to the different aims and methods of breeding programs. (author)

  7. TH-AB-209-07: High Resolution X-Ray-Induced Acoustic Computed Tomography

    Energy Technology Data Exchange (ETDEWEB)

    Xiang, L; Tang, S [University of Oklahoma, Norman, OK (United States); Ahmad, M [Stanford University, Palo Alto, CA (United States); Xing, L [Stanford University School of Medicine, Stanford, CA (United States)

    2016-06-15

    Purpose: X-ray radiographic absorption imaging is an invaluable tool in medical diagnostics, biology and materials science. However, the use of conventional CT is limited by two factors: the detection sensitivity to weak absorption material and the radiation dose from CT scanning. The purpose of this study is to explore X-ray induced acoustic computed tomography (XACT), a new imaging modality, which combines X-ray absorption contrast and high ultrasonic resolution to address these challenges. Methods: First, theoretical models was built to analyze the XACT sensitivity to X-ray absorption and calculate the minimal radiation dose in XACT imaging. Then, an XACT system comprised of an ultrashort X-ray pulse, a low noise ultrasound detector and a signal acquisition system was built to evaluate the X-ray induced acoustic signal generation. A piece of chicken bone and a phantom with two golden fiducial markers were exposed to 270 kVp X-ray source with 60 ns exposure time, and the X-ray induced acoustic signal was received by a 2.25MHz ultrasound transducer in 200 positions. XACT images were reconstructed by a filtered back-projection algorithm. Results: The theoretical analysis shows that X-ray induced acoustic signals have 100% relative sensitivity to X-ray absorption, but not to X-ray scattering. Applying this innovative technology to breast imaging, we can reduce radiation dose by a factor of 50 compared with newly FDA approved breast CT. The reconstructed images of chicken bone and golden fiducial marker phantom reveal that the spatial resolution of the built XACT system is 350µm. Conclusion: In XACT, the imaging sensitivity to X-ray absorption is improved and the imaging dose is dramatically reduced by using ultrashort pulsed X-ray. Taking advantage of the high ultrasonic resolution, we can also perform 3D imaging with a single X-ray pulse. This new modality has the potential to revolutionize x-ray imaging applications in medicine and biology.

  8. Carborne gamma-ray spectrometry. Calibration and applications

    International Nuclear Information System (INIS)

    Aage, H.K.; Korsbech, U.; Bargholz, K.; Hovgaard, J.

    2006-01-01

    Calibration of carborne gamma-ray spectrometry systems for 137 Cs is carried out with a source successively placed at 791 positions within an area of 34 mx62 m. A computer model supplements the measurements. Hereby a sensitivity map for a surface contamination is generated as well as line and area sensitivities. Another model converts surface sensitivity to sensitivity for a deep contamination. Use of the sensitivity map for a non-homogeneous distribution of 137 Cs is demonstrated. Applications of line sensitivities for special tasks are discussed

  9. Ultra high-energy cosmic ray composition

    International Nuclear Information System (INIS)

    Longley, N.P.

    1993-01-01

    The Soudan 2 surface-underground cosmic ray experiment can simultaneously measure surface shower size, underground muon multiplicity, and underground muon separation for ultra high energy cosmic ray showers. These measurements are sensitive to the primary composition. Analysis for energies from 10 1 to 10 4 TeV favors a light flux consisting of predominantly H and He nuclei

  10. X-ray spectromicroscopy studies of protein-polymer Interactions

    International Nuclear Information System (INIS)

    Hitchcock, A.P.; Tyliszczak, T.; Heng, Y.M.; Cornelius, R.; Brash, J.L.; Ade, H.; Anders, S.; Scholl, A.; Nolting, F.

    2000-01-01

    Identification of the sites of protein binding on laterally heterogeneous polymer surfaces can help understand mechanisms of bio-passivation, which in turn has practical impact on developing improved polymers for medical uses, such as blood contact applications. We have used scanning X-ray transmission microscopy and photoelectron emission microscopy to explore the sensitivity of these X-ray microscopies to detection of human serum albumin adsorbed onto the surface of two different polyurethane polymers. Both techniques appear capable of the requisite monolayer sensitivity

  11. The combination of an industrial X-ray-film with a vacuum-adapter instead of a foil-less industrial X-ray-film

    International Nuclear Information System (INIS)

    Kurz, C.S.; Rotte, K.

    1980-01-01

    In clinical routine it was proved, how far an industrial X-ray-film in combination with the low-dose-system gives the same evidence as an foil-less industrial X-ray-film. Patients which had got in the past a mammography at both sides with a foil-less industrial X-ray-film received a mammography at both sides with the low-dose-system. Both X-rays were compared in the following criteria: artefacts, micro-calcifications, structure-differentiation, difinition, contrast, exposure, time of diagnosis and overal impression. Considering an evident dose reduction by the low-dose-system the result is, that a film-foil-combination with a vacuum-adapter is available without impairment of diagnostic evidence in clinical routine. (orig.) [de

  12. Increased sensitivity in thick-target particle induced X-ray emission analyses using dry ashing for preconcentration

    International Nuclear Information System (INIS)

    Lill, J.-O.; Harju, L.; Saarela, K.-E.; Lindroos, A.; Heselius, S.-J.

    1999-01-01

    The sensitivity in thick-target particle induced X-ray emission (PIXE) analyses of biological materials can be enhanced by dry ashing. The gain depends mainly on the mass reduction factor and the composition of the residual ash. The enhancement factor was 7 for the certified reference material Pine Needles and the limits of detection (LODs) were below 0.2 μg/g for Zn, Cu, Rb and Sr. When ashing biological materials with low ash contents such as wood of pine or spruce (0.3% of dry weight) and honey (0.1% of wet weight) the gain was far greater. The LODs for these materials were 30 ng/g for wood and below 10 ng/g for honey. In addition, the ashed samples were more homogenous and more resistant to changes during the irradiation than the original biological samples. (Copyright (c) 1999 Elsevier Science B.V., Amsterdam. All rights reserved.)

  13. A two-dimensional low energy gamma-ray position sensitive detector

    International Nuclear Information System (INIS)

    Charalambous, P.M.; Dean, A.J.; Drane, M.; Gil, A.; Stephen, J.B.; Young, N.G.S.; Barbareschi, L.; Perotti, F.; Villa, G.; Badiali, M.; La Padula, C.; Polcaro, F.; Ubertini, P.

    1984-01-01

    An array of 1-dimensional position sensitive detectors designed to operate over the photon energy range 0.2-10.0 MeV, so as to form an efficient 2-dimensional position sensitive detection plane is described. A series of experimental tests has been carried out to evaluate and confirm the computed capabilities. (orig.)

  14. Prompt Gamma Ray Spectroscopy for process monitoring

    International Nuclear Information System (INIS)

    Zoller, W.H.; Holmes, J.L.

    1991-01-01

    Prompt Gamma Ray Spectroscopy (PGRS) is a very powerful analytical technique able to measure many metallic, contamination problem elements. The technique involves measurement of gamma rays that are emitted by nuclei upon capturing a neutron. This method is sensitive not only to the target element but also to the particular isotope of that element. PGRS is capable of measuring dissolved metal ions in a flowing system. In the field, isotopic neutron sources are used to produce the desired neutron flux ( 252 Cf can produce neutron flux of the order of 10 8 neutrons/cm 2 --sec.). Due to high penetrating power of gamma radiation, high efficiency gamma ray detectors can be placed in an appropriate geometry to maximize sensitivity, providing real-time monitoring with low detection level capabilities

  15. Medical imaging: Material change for X-ray detectors

    Science.gov (United States)

    Rowlands, John A.

    2017-10-01

    The X-ray sensitivity of radiology instruments is limited by the materials used in their detectors. A material from the perovskite family of semiconductors could allow lower doses of X-rays to be used for medical imaging. See Letter p.87

  16. Video Quality Assessment Using Spatio-Velocity Contrast Sensitivity Function

    Science.gov (United States)

    Hirai, Keita; Tumurtogoo, Jambal; Kikuchi, Ayano; Tsumura, Norimichi; Nakaguchi, Toshiya; Miyake, Yoichi

    Due to the development and popularization of high-definition televisions, digital video cameras, Blu-ray discs, digital broadcasting, IP television and so on, it plays an important role to identify and quantify video quality degradations. In this paper, we propose SV-CIELAB which is an objective video quality assessment (VQA) method using a spatio-velocity contrast sensitivity function (SV-CSF). In SV-CIELAB, motion information in videos is effectively utilized for filtering unnecessary information in the spatial frequency domain. As the filter to apply videos, we used the SV-CSF. It is a modulation transfer function of the human visual system, and consists of the relationship among contrast sensitivities, spatial frequencies and velocities of perceived stimuli. In the filtering process, the SV-CSF cannot be directly applied in the spatial frequency domain because spatial coordinate information is required when using velocity information. For filtering by the SV-CSF, we obtain video frames separated in spatial frequency domain. By using velocity information, the separated frames with limited spatial frequencies are weighted by contrast sensitivities in the SV-CSF model. In SV-CIELAB, the criteria are obtained by calculating image differences between filtered original and distorted videos. For the validation of SV-CIELAB, subjective evaluation experiments were conducted. The subjective experimental results were compared with SV-CIELAB and the conventional VQA methods such as CIELAB color difference, Spatial-CIELAB, signal to noise ratio and so on. From the experimental results, it was shown that SV-CIELAB is a more efficient VQA method than the conventional methods.

  17. Neural network Hilbert transform based filtered backprojection for fast inline x-ray inspection

    Science.gov (United States)

    Janssens, Eline; De Beenhouwer, Jan; Van Dael, Mattias; De Schryver, Thomas; Van Hoorebeke, Luc; Verboven, Pieter; Nicolai, Bart; Sijbers, Jan

    2018-03-01

    X-ray imaging is an important tool for quality control since it allows to inspect the interior of products in a non-destructive way. Conventional x-ray imaging, however, is slow and expensive. Inline x-ray inspection, on the other hand, can pave the way towards fast and individual quality control, provided that a sufficiently high throughput can be achieved at a minimal cost. To meet these criteria, an inline inspection acquisition geometry is proposed where the object moves and rotates on a conveyor belt while it passes a fixed source and detector. Moreover, for this acquisition geometry, a new neural-network-based reconstruction algorithm is introduced: the neural network Hilbert transform based filtered backprojection. The proposed algorithm is evaluated both on simulated and real inline x-ray data and has shown to generate high quality reconstructions of 400  ×  400 reconstruction pixels within 200 ms, thereby meeting the high throughput criteria.

  18. X-ray sensitive strains of CHO cells show decreased frequency of stable transfection

    International Nuclear Information System (INIS)

    Jeggo, P.; Smith, J.

    1987-01-01

    Six X-ray sensitive (xrs) strains of the Chinese hamster ovary cell line have previously been isolated and shown to have a defect in double strand break rejoining. In this study, these strains have been investigated for their ability to take up and integrate foreign DNA. All the xrs strains investigated so far have shown a decreased frequency of stable transfectants compared to their parent line, in experiments using the plasmid pSV2gpt, which contains the selectable bacterial gene, guanine phosphoribosyl transferase. This decreased frequency is observed over a wide range of DNA concentrations (0.1 to 20 μg DNA) but is more pronounced at higher DNA concentrations. In contrast, these xrs strains show the same level of transfection proficiency as the wild type parent using a transient transfection system with a plasmid containing the bacterial CAT (chloramphenicol acetyl transferase) gene. Since the level of CAT activity does not depend on integration of foreign DNA, this suggests that the xrs strains are able to take up the same amount of DNA as the parent strains, but have a defect in the integration of foreign DNA. Since this integration of foreign DNA probably occurs by non-homologous recombination, this may indicate a role of the xrs gene product in this process

  19. Trends in x-ray photography and patient exposure dose

    International Nuclear Information System (INIS)

    Orito, Takeo; Sanada, Shigeru; Maekawa, Ryuichi; Koshida, Kichiro; Hiraki, Tatsunosuke

    1980-01-01

    The exposure doses of patients in X-ray photography are influenced by such technological factors as X-ray tube voltage, filter, sensitizing screen, film and grid. Survey by questionnnaire was made previously in 1973 on the above factors. The trends five years after were surveyed similarly, in connection with the exposure doses of patients. Questionnaires were sent to 200 radiation technicians, and 121 (60.5%) answered the survey in March, 1979. The results in the cases of simple X-ray photography and obstetric, infant and breast X-ray photographings are described. X-ray tube voltage is generally on the increase. In the sensitizing screens, exposure doses are fairly decreased due to the use of improved intensifying screen (LT-II). In the grid, the ratio 8 : 1 is used more than 5 : 1. In the usage of additional filters and in the distance of photography, improvements are desired. (J.P.N.)

  20. Combined multi-criteria and cost-benefit analysis

    DEFF Research Database (Denmark)

    Moshøj, Claus Rehfeld

    1996-01-01

    The paper is an introduction to both theory and application of combined Cost-Benefit and Multi-Criteria Analysis. The first section is devoted to basic utility theory and its practical application in Cost-Benefit Analysis. Based on some of the problems encountered, arguments in favour...... of the application of utility-based Multi-Criteria Analyses methods as an extension and refinement of the traditional Cost-Benefit Analysis are provided. The theory presented in this paper is closely related the methods used in the WARP software (Leleur & Jensen, 1989). The presentation is however wider in scope.......The second section introduces the stated preference methodology used in WARP to create weight profiles for project pool sensitivity analysis. This section includes a simple example. The third section discusses how decision makers can get a priori aid to make their pair-wise comparisons based on project pool...

  1. X-ray imaging in the laser-fusion program

    International Nuclear Information System (INIS)

    McCall, G.H.

    1977-01-01

    Imaging devices which are used or planned for x-ray imaging in the laser-fusion program are discussed. Resolution criteria are explained, and a suggestion is made for using the modulation transfer function as a uniform definition of resolution for these devices

  2. X-ray fluorescence spectrometry

    International Nuclear Information System (INIS)

    Ray, N.B.

    1977-01-01

    The principle, instrument and procedure of X-ray fluorescence spectrometry are described. It is a rapid, simple and sensitive method for the trace analysis of elements from sodium to uranium in powder, liquid or metal samples. (M.G.B.)

  3. Method of producing a pseudo-color photograph with X-rays

    Energy Technology Data Exchange (ETDEWEB)

    Tajima, M

    1965-05-08

    Conventional black and white X-ray photography cannot simultaneously produce an image on photographic film of a subject having regions of high and low X-ray absorption due to the limitation of photographic density range, gradation and exposure tolerance. This invention records both regions as images of different colors on the same color photographic film. According to a method of this invention for making an X-ray pseudo-color photograph, the subject is directly irradiated by an X-ray beam emergent from an X-ray beam generator, and an X-ray permeation image of the subject is converted into and displayed as a visible light image by means of a fluorescent screen. In one aspect of this invention, there is used a color photographic film which has at least two kinds of sensitive and coloring layers exhibiting the same sensitivity. During the period in which the visible image is displayed, the film is exposed to the visible light in such a way that at least two color filters differing in color and density are successively interposed between the film and the fluorescent screen. In another aspect, a color photographic film is employed having at least two kinds of sensitive and coloring layers exhibiting different sensitivities. During the period in which the visible image is displayed, the film is exposed to visible light by sequentially interposing at least two color filters of different color but of equal density. In this manner, regions comparatively low in X-ray absorption, such as the lungs, and regions comparatively high in absorption, such as the heart, appear as, for example, a blue image and a red image on the color photographic film, respectively.

  4. Clinical Implications of Various Criteria for the Biochemical Diagnosis of Insulinoma

    Directory of Open Access Journals (Sweden)

    Chang Ho Ahn

    2014-12-01

    Full Text Available BackgroundAmong the various diagnostic criteria for insulinoma, the ratio criteria have been controversial. However, the amended insulin-glucose ratio exhibited excellent diagnostic performance in a recent retrospective cohort study, although it has not yet been validated in other patient cohorts. We examined the diagnostic performance of the current criteria of the Endocrine Society, insulin-glucose ratio, C-peptide-glucose ratio, and amended ratios in terms of differentiating insulinomas.MethodsWe reviewed the medical records of patients who underwent evaluation for hypoglycemia from 2000 to 2013. Fourteen patients with histopathologically confirmed insulinoma and 18 patients without clinical evidence of insulinoma were included. The results of a prolonged fast test were analyzed according to the abovementioned criteria.ResultsFulfilling all three Endocrine Society criteria-plasma levels of glucose (24.0 (pmol/L/(mmol/L] gave the highest area under the receiver operating characteristic curve, with 93% sensitivity and 94% specificity.ConclusionFulfilling the glucose, insulin, and C-peptide criteria of the Endocrine Society guidelines exhibited the best diagnostic performance for insulinoma. Nonetheless, the insulin-glucose ratio may still have a role in the biochemical diagnosis of insulinoma.

  5. A study of gamma-ray bursts and a new detector for gamma-ray astronomy

    International Nuclear Information System (INIS)

    Carter, J.N.

    1979-09-01

    Three gamma-ray experiments flown on balloons between August 1975 and August 1976 are described in detail. The successful Transatlantic balloon flight enabled a rate of 3 bursts year -1 with energies > 7 x 10 -7 ergs cm -2 to be established. This result is discussed in the light of other work. The choice of γ-ray detector for optimum sensitivity is presented. In addition various techniques for determining the arrival direction of gamma-ray bursts are compared. A new balloon borne γ-ray burst telescope is proposed. The design, testing and results of the beam calibration of a new drift chamber detector system for high energy (> 50 MeV) γ-rays are presented. A projected angular resolution of 0.8 0 was obtained at 300 MeV. Techniques for the measurement of γ-ray energies are discussed in relation to this instrument. Finally the use of drift chambers in an integrated free flying satellite is illustrated, and the expected performance is presented. (author)

  6. Selective Beta and Gamma-ray Discrimination by CdWO{sub 4} and PlasticScintillator

    Energy Technology Data Exchange (ETDEWEB)

    Bae, Jun Woo; Kim, Hee Reyoung [Dept. of Nuclear Engineering, Ulsan National Institute of Science and Technology, Ulsan (Korea, Republic of)

    2017-04-15

    Radiation monitoring technique has been used for monitoring of decommissioning site of nuclear facility, radioactive waste disposal site, or in case of radioactivity accident. For rapid measurement of gamma-ray and beta-ray, many portable radiation detectors were developed but they are sensitive to specific radiation type. For example, portable detectors using NaI(Tl) or high purity germanium (HPGe) are suitable to detect gamma-ray. Otherwise, Geiger-müller (GM) tube or ionization chamber are suitable to detect all-types of radiation but it is hard to determine which particle is detected in the detector. In this reason, phoswich detectors for discrimination of beta-ray and gamma-ray were developed by using pulse shape discrimination. In this study, another approach to discriminate the beta-ray and gamma-ray is carried out. Two scintillators are used, cadmium tungstate (CdWO{sub 4}) and plastic scintillator. They have huge difference in their effective atomic number and mass density, thus they have huge difference in their gamma-ray sensitivity while the sensitivity of beta-ray is similar. The characterization of beta-ray and gamma-ray discrimination by using this characteristics is include. A technique of discrimination between beta-ray and gamma-ray was suggested. The method was verified by Monte Carlo simulation and experiment. This work showed feasibility on in field measurement of radiation with discrimination of beta-ray and gamma-ray.

  7. Collimatorless imaging of gamma rays with help of gamma-ray tracking

    CERN Document Server

    Marel, J V D

    2001-01-01

    In many gamma-ray detector systems that are built for imaging purposes Compton scattered photons are suppressed as much as possible. However, the information from photons that scattered inside a detector system can be used to reconstruct the tracks of the photons with help of gamma-ray tracking. Estimates of the incident directions of the photons can be made and an image can be created. Examples of potential applications for this technique are the use as a gamma-camera in medical imaging (e.g. SPECT) or as a detector for PET. Due to the omission of collimators, much higher detection efficiencies can be achieved, reducing the doses required for an image. A gamma-ray tracking method, called backtracking, has been developed for nuclear spectroscopy. The method tracks gamma-rays originating from a point source in the center of a spherical detector system consisting of position-sensitive germanium detectors. This method can also be used as a tracking technique for imaging of an unknown source distribution. With he...

  8. Gamma detector for use with luggage X-ray systems

    International Nuclear Information System (INIS)

    McHugh, H.; Quam, W.

    1998-01-01

    A new gamma radiation sensor has been designed for installation on several types of luggage x-ray machines and mobile x-ray vans operated by the U.S. Customs Service and the U.S. Department of State. The use of gamma detectors on x-ray machines imposed difficulties not usually encountered in the design of gamma detectors because the spectrum of scattered x-rays, which varied from machine to machine, extended to energies significantly higher than those of the low-energy isotopic emissions. In the original design, the lower level discriminator was raised above the x-ray end point energy resulting in the loss of the americium line associated with plutonium. This reduced the overall sensitivity to unshielded plutonium by a factor of approximately 100. An improved method was subsequently developed wherein collimation was utilized in conjunction with a variable counting threshold to permit accommodation of differing conditions of x-ray scattering. This design has been shown to eliminate most of the problems due to x-ray scattering while still capturing the americium emissions. The overall sensitivity has remained quite high, though varying slightly from one model of x-ray machine to another, depending upon the x-ray scattering characteristics of each model. (author)

  9. Criteria to stablish an absolute semiquantitative analytic method by x-ray fluorescence

    International Nuclear Information System (INIS)

    Echeverria, Fernando.

    1990-01-01

    This work had been developed by fluorescence x-ray laboratory of Nuclear Studies Centre form Ecuador, it pretent to stablish an appropiate discernement of a FRX spectrum to know the concentration range form sample elements, minerals principaly, submit to a FRX. The study tries to stablish the best way to calibration the instruments like the adecuate samples preparation to do the analysis by FRX

  10. Dose Evaluation and Quality Criteria in Dental Radiology

    International Nuclear Information System (INIS)

    Gori, C.; Rossi, F.; Stecco, A.; Villari, N.; Zatelli, G.

    2000-01-01

    Radioprotection in dental radiology is of particular interest in the framework of the Revised Medical Exposure Directive for the great number of examinations involving the adult as well as the paediatric population (Article 9: Special Practice). The present study is intended to find the quality criteria of orthodontic imaging and for evaluating the dose absorbed within the dental and maxillary volume in connection with radiological examinations performed with either spiral CT, dental panoramic tomography or teleradiography. The X ray dose to organs sited in the body, neck, ocular and intracranial area was measured using lithium fluoride dosemeters, positioned in a Rando phantom. Quality criteria have been established by an expert radiologist considering the diagnostic information obtained in the images. The dosimetric data obtained were comparable with other authors', although with some differences due to technical characteristics. These result data are useful for choosing the patient's diagnostic path, considering the radiobiological risk associated with increasing orthodontic imaging. (author)

  11. Effective and cheap X-ray television detector

    International Nuclear Information System (INIS)

    Artem'ev, A.N.; Potlovskij, K.G.; Rezvov, V.A.; Yudin, L.I.

    2002-01-01

    The position sensitive detector (PSD) is designed for investigations with traditional X-ray tubes and synchrotron radiation from 3 to 30 keV. PSD consists of light-tight box, which transforms X-ray photons to light photons. Light photons are registered with the help of TV camera. Then an image is digitized and introduced into computer. Software provides registration of the dim beam images by means of accumulation of the information. Statistic processing of the image series allows to determine of the parameters of the image. Sensitivity is 41 phot/pixel. Spatial resolution is not worse then 400 μ [ru

  12. Stellar and solar X-ray polarimetry

    Energy Technology Data Exchange (ETDEWEB)

    Novick, R [Columbia Univ., New York (USA)

    1975-12-01

    The scientific motivation for X-ray polarimetry is discussed with particular emphasis on the information that might be obtained on the binary X-ray pulsars in addition to a number of other classes of objects including solar flares. Detailed discussions are given for Thomson-scattering and Bragg-crystal polarimeters with numerical estimates for the sensitivity of various existing and proposed instruments.

  13. X-ray microanalysis in plant physiology

    International Nuclear Information System (INIS)

    Neumann, D.

    1979-01-01

    X-ray microanalysis represents a highly sensitive and modern method for the measurement of ions in the very small compartments of the cell. The limitations of X-ray microanalysis in biological objects exist in the preparation of the tissues and the quantitation of the results. In plant physiology this method has provided several surprising results and new insights for further investigations. (author)

  14. Ultra fast x-ray streak camera

    International Nuclear Information System (INIS)

    Coleman, L.W.; McConaghy, C.F.

    1975-01-01

    A unique ultrafast x-ray sensitive streak camera, with a time resolution of 50psec, has been built and operated. A 100A thick gold photocathode on a beryllium vacuum window is used in a modified commerical image converter tube. The X-ray streak camera has been used in experiments to observe time resolved emission from laser-produced plasmas. (author)

  15. Towards Hydrological Applications of Stationary and Roving Cosmic-Ray Neutron Sensors in the Light of Spatial Sensitivity

    Science.gov (United States)

    Schrön, M.; Köhli, M.; Rosolem, R.; Baroni, G.; Bogena, H. R.; Brenner, J.; Zink, M.; Rebmann, C.; Oswald, S. E.; Dietrich, P.; Samaniego, L. E.; Zacharias, S.

    2017-12-01

    Cosmic-Ray Neutron Sensing (CRNS) has become a promising and unique method to monitor water content at an effective scale of tens of hectares in area and tens of centimeters in depth. The large footprint is particularly beneficial for hydrological models that operate at these scales.However, reliable estimates of average soil moisture require a detailed knowledge about the sensitivity of the signal to spatial inhomogeneity within the footprint. From this perspective, the large integrating volume challenges data interpretation, validation, and calibration of the sensor. Can we still generate reliable data for hydrological applications? One of the top challenges in the last years was to find out where the signal comes from, and how sensitive it is to spatial variabilities of moisture. Neutron physics simulations have shown that the neutron signal represents a non-linearly weighted average of soil water in the footprint. With the help of the so-called spatial sensitivity functions it is now possible to quantify the contribution of certain regions to the neutron signal. We present examples of how this knowledge can help (1) to understand the contribution of irrigated and sealed areas in the footprint, (2) to improve calibration and validation of the method, and (3) to even reveal excess water storages, e.g. from ponding or rain interception.The spatial sensitivity concept can also explain the influence of dry roads on the neutron signal. Mobile surveys with the CRNS rover have been a common practice to measure soil moisture patterns at the kilometer scale. However, dedicated experiments across agricultural fields in Germany and England have revealed that field soil moisture is significantly underestimated when moving the sensor on roads. We show that knowledge about the spatial sensitivity helps to correct survey data for these effects, depending on road material, width, and distance from the road. The recent methodological advances allow for improved signal

  16. The Advanced Gamma-ray Imaging System (AGIS): Simulation Studies

    OpenAIRE

    Maier, G.; Collaboration, for the AGIS

    2009-01-01

    The Advanced Gamma-ray Imaging System (AGIS) is a next-generation ground-based gamma-ray observatory being planned in the U.S. The anticipated sensitivity of AGIS is about one order of magnitude better than the sensitivity of current observatories, allowing it to measure gammaray emmission from a large number of Galactic and extra-galactic sources. We present here results of simulation studies of various possible designs for AGIS. The primary characteristics of the array performance - collect...

  17. Elimination of pain improves specificity of clinical diagnostic criteria for adult chronic rhinosinusitis.

    Science.gov (United States)

    Hirsch, Scott D; Reiter, Evan R; DiNardo, Laurence J; Wan, Wen; Schuman, Theodore A

    2017-05-01

    Determine whether the elimination of pain improves accuracy of clinical diagnostic criteria for adult chronic rhinosinusitis. Retrospective cohort study. History, symptoms, nasal endoscopy, and computed tomography (CT) results were analyzed for 1,186 adults referred to an academic otolaryngology clinic with presumptive diagnosis of chronic rhinosinusitis. Clinical diagnosis was rendered using the 1997 Rhinosinusitis Taskforce (RSTF) Guidelines and a modified version eliminating facial pain, ear pain, dental pain, and headache. Four hundred seventy-nine subjects (40%) met inclusion criteria. Among subjects positive by RSTF guidelines, 45% lacked objective evidence of sinonasal inflammation by CT, 48% by endoscopy, and 34% by either modality. Applying modified RSTF diagnostic criteria, 39% lacked sinonasal inflammation by CT, 38% by endoscopy, and 24% by either modality. Using either abnormal CT or endoscopy as the reference standard, modified diagnostic criteria yielded a statistically significant increase in specificity from 37.1% to 65.1%, with a nonsignificant decrease in sensitivity from 79.2% to 70.3%. Analysis of comorbidities revealed temporomandibular joint disorder, chronic cervical pain, depression/anxiety, and psychiatric medication use to be negatively associated with objective inflammation on CT or endoscopy. Clinical diagnostic criteria overestimate the prevalence of chronic rhinosinusitis. Removing facial pain, ear pain, dental pain, and headache increased specificity without a concordant loss in sensitivity. Given the high prevalence of sinusitis, improved clinical diagnostic criteria may assist primary care providers in more accurately predicting the presence of inflammation, thereby reducing inappropriate antibiotic use or delayed referral for evaluation of primary headache syndromes. 4. Laryngoscope, 127:1011-1016, 2017. © 2017 The American Laryngological, Rhinological and Otological Society, Inc.

  18. Space- and time-resolved diagnostics of soft x-ray emission from laser plasmas

    International Nuclear Information System (INIS)

    Richardson, M.C.; Jaanimagi, P.A.; Chen, H.

    1988-01-01

    The analysis of soft x-ray emission from plasmas created by intense short-wavelength laser radiation can provide much useful information on the density, temperature and ionization distribution of the plasma. Until recently, limitations of sensitivity and the availability of suitable x-ray optical elements have restricted studies of soft x-ray emission from laser plasmas. In this paper, the authors describe novel instrumentation which provides high sensitivity in the soft x-ray spectrum with spatial and temporal resolution in the micron and picosecond ranges respectively. These systems exploit advances made in soft x-ray optic and electro-optic technology. Their application in current studies of laser fusion, x-ray lasers, and high density atomic physics are discussed

  19. Neurophysiological criteria in the diagnosis of different clinical types of Guillain-Barre syndrome.

    Science.gov (United States)

    Kalita, J; Misra, U K; Das, M

    2008-03-01

    The diagnostic yield of various neurophysiological criteria may vary in different subforms of Guillain-Barre syndrome (GBS), whose prevalence varies in different geographical areas. To evaluate the sensitivity of various neurophysiological criteria in different clinical subtypes of GBS, and their relationship with severity, duration and outcome. Consecutive patients with GBS underwent detailed clinical evaluation. Severity was graded on a scale from 0 to 10. Motor and sensory nerve conductions and F wave studies were performed. The diagnostic sensitivity of Albers et al (set 1), Cornblath (set 2), Ho et al (set 3), Dutch GBS study group (set 4), Italian GBS study group (set 5) and Albers and Kelly (set 6) criteria were evaluated and correlated with clinical subtypes of GBS, duration, severity and outcome. There were 51 patients. Mean disability was 6.8; 34 patients were bedridden and five needed a ventilator. Clinical presentation was pure motor in 31, motorsensory in 18 and pure sensory in two patients. The sensitivity of nerve conduction study in the diagnosis of GBS was highest in set 1 (88.2%) followed by set 3 (86.3%) and set 4 (82.4%) and lowest in set 2 (39.2%). The diagnostic yield of sets 1, 3 and 4 were also higher than sets 2, 5 and 6 in different clinical subtypes of GBS. As per Ho et al, patients could be categorised into acute inflammatory demyelinating polyradiculoneuropathy (44 (86.3%)), acute motor axonal neuropathy (4 (7.8%)) and acute motor sensory axonal neuropathy (3 (5.9%)). One (2%) patient died, 22.4% had complete, 57.1% partial and 18.4% poor recovery at 3 months. Outcome was related to severity of illness and compound muscle action potential (CMAP) amplitude. The sensitivity of different neurophysiological criteria in the diagnosis of Indian GBS patients varied from 39.2% to 88.2%. The outcome was related to severity of illness and CMAP amplitude.

  20. Use of external cost assessment and multi-criteria decision analysis for comparative evaluation of options for electricity supply

    International Nuclear Information System (INIS)

    Hirschberg, Stefan; Dones, Roberto; Gantner, Urs

    2000-01-01

    This paper addresses external cost and multi-criteria analyses carried out for selected future electricity generating systems of interest under the Swiss. conditions. The external cost estimates are based on an application of the 'impact pathway approach', enriched by earlier experience from extensive Life Cycle Assessment (LCA). The estimated total costs, i.e. the sum of internal and external costs may serve as a measure of economic and environmental efficiency of energy systems. The multi-criteria approach allows a more explicit consideration of the social dimension, highly important for the decision process. The applications of multi-criteria analysis illustrate the sensitivity of the results to a range of preferences expressed in the energy debate. Certain patterns in systems ranking can be observed in spite of these sensitivities. Both total cost assessment and multi-criteria analysis are found to be useful, complementary instruments to support the decision process. (author)

  1. EVALUATION OF ULTRASOUND REMISSION CRITERIA IN PATIENTS WITH RHEUMATOID ARTHRITIS DURING TOCILIZUMAB THERAPY

    Directory of Open Access Journals (Sweden)

    Rita Aleksandrovna Osipyants

    2013-01-01

    Full Text Available Objective: to study the association of ultrasound (US remission criteria with the clinical and laboratory indicators of inflammatory activity, functional status, and X-ray changes in patients with rheumatoid arthritis (RA during tocilizumab (TCZ therapy.Subjects and methods. The trial included 36 patients with RA (meeting the 1987 American College of Rheumatology (ACR criteria who had received TCZ for 6 months. The authors made a clinical and laboratory assessment of RA activity (DAS28-CRP, and SDAI, functional impairments (HAQ index and US verification of wrist joint synovitis (a Voluson-i device, GE, 4-13-MHz linear transducer at baseline and 6 months after therapy. No signs of grey-scale (B-mode and power Doppler (PD synovitis (B = 0; PD = 0 or minimal B-mode synovitis, and not more one PD hypervascular signal (В ≤1; PD ≤1 were arbitrarily taken as US remission criteria. Destruction changes were evaluated by hand and foot X-ray using the Sharp method modified by van der Heijde (SHS.Results. After 6 months of therapy, about 80% of the patients in clinical remission retained moderate or significant synovitis, as evidenced by US studies. There were no clinical differences in clinical activity indices and functional impairments between the patients who were and were not in US remission (p > 0.05. The 12-month follow-up SHS score was significantly higher with the preservation of 6-month therapy signs of B-mode synovitis and PD hypervascularization (of not more than one signal than that in US remission (p < 0.05. There was no relationship of X-ray progression to the clinical and functional statuses (p > 0.05.Conclusion. Subclinical synovitis is observed even in clinical remission of RA. Destruction progression is significantlyrelated to synovitis persistence, as shown by ultrasonography.

  2. Hard X-ray Photoelectric Polarimeter

    Data.gov (United States)

    National Aeronautics and Space Administration — Our objective is to determine the gas mixtures and pressures that would enable a sensitive, hard X-ray polarimeter using existing flight components with the goal of...

  3. The Advanced Gamma-ray Imaging System (AGIS)-Science Highlights

    Science.gov (United States)

    Buckley, J.; Coppi, P.; Digel, S.; Funk, S.; Krawczynski, H.; Krennrich, F.; Pohl, M.; Romani, R.; Vassiliev, V.

    2008-12-01

    The Advanced Gamma-ray Imaging System (AGIS), a future gamma-ray telescope consisting of an array of ~50 atmospheric Cherenkov telescopes distributed over an area of ~1 km2, will provide a powerful new tool for exploring the high-energy universe. The order-of-magnitude increase in sensitivity and improved angular resolution could provide the first detailed images of γ-ray emission from other nearby galaxies or galaxy clusters. The large effective area will provide unprecedented sensitivity to short transients (such as flares from AGNs and GRBs) probing both intrinsic spectral variability (revealing the details of the acceleration mechanism and geometry) as well as constraining the high-energy dispersion in the velocity of light (probing the structure of spacetime and Lorentz invariance). A wide field of view (~4 times that of current instruments) and excellent angular resolution (several times better than current instruments) will allow for an unprecedented survey of the Galactic plane, providing a deep unobscured survey of SNRs, X-ray binaries, pulsar-wind nebulae, molecular cloud complexes and other sources. The differential flux sensitivity of ~10-13 erg cm-2 sec-1 will rival the most sensitive X-ray instruments for these extended Galactic sources. The excellent capabilities of AGIS at energies below 100 GeV will provide sensitivity to AGN and GRBs out to cosmological redshifts, increasing the number of AGNs detected at high energies from about 20 to more than 100, permitting population studies that will provide valuable insights into both a unified model for AGN and a detailed measurement of the effects of intergalactic absorption from the diffuse extragalactic background light. A new instrument with fast-slewing wide-field telescopes could provide detections of a number of long-duration GRBs providing important physical constraints from this new spectral component. The new array will also have excellent background rejection and very large effective area

  4. Lung scintigraphy in the diagnosis of pulmonary embolism: current methods and interpretation criteria in clinical practice

    International Nuclear Information System (INIS)

    Skarlovnik, Ajda; Hrastnik, Damjana; Fettich, Jure; Grmek, Marko

    2014-01-01

    In current clinical practice lung scintigraphy is mainly used to exclude pulmonary embolism (PE). Modified diagnostic criteria for planar lung scintigraphy are considered, as newer scitigraphic methods, especially single photon emission computed tomography (SPECT) are becoming more popular. Data of 98 outpatients who underwent planar ventilation/perfusion (V/Q) scintigraphy and 49 outpatients who underwent V/Q SPECT from the emergency department (ED) were retrospectively collected. Planar V/Q images were interpreted according to 0.5 segment mismatch criteria and revised PIOPED II criteria and perfusion scans according to PISA-PED criteria. V/Q SPECT images were interpreted according to the criteria suggested in EANM guidelines. Final diagnosis of PE was based on the clinical decision of an attending physician and evaluation of a 12 months follow-up period. Using 0.5 segment mismatch criteria and revised PIOPED II, planar V/Q scans were diagnostic in 93% and 84% of cases, respectively. Among the diagnostic planar scans readings specificity for 0.5 segment mismatch criteria was 98%, and 99% for revised PIOPED II criteria. V/Q SPECT showed a sensitivity of 100% and a specificity of 98%, without any non-diagnostic cases. In patients with low pretest probability for PE, planar V/Q scans assessed by 0.5 segment mismatch criteria were diagnostic in 92%, and in 85% using revised PIOPED II criteria, while perfusion scintigraphy without ventilation scans was diagnostic in 80%. Lung scintigraphy yielded diagnostically definitive results and is reliable in ruling out PE in patients from ED. V/Q SPECT has excellent specificity and sensitivity without any non-diagnostic results. Percentage of non-diagnostic results in planar lung scintigraphy is considerably smaller when 0.5 segment mismatch criteria instead of revised PIOPED II criteria are used. Diagnostic value of perfusion scintigraphy according to PISA-PED criteria is inferior to combined V/Q scintigraphy; the difference is

  5. X-ray fluorescence method for trace analysis and imaging

    International Nuclear Information System (INIS)

    Hayakawa, Shinjiro

    2000-01-01

    X-ray fluorescence analysis has a long history as conventional bulk elemental analysis with medium sensitivity. However, with the use of synchrotron radiation x-ray fluorescence method has become a unique analytical technique which can provide tace elemental information with the spatial resolution. To obtain quantitative information of trace elemental distribution by using the x-ray fluorescence method, theoretical description of x-ray fluorescence yield is described. Moreover, methods and instruments for trace characterization with a scanning x-ray microprobe are described. (author)

  6. Method of producing a pseudo-color photograph with X-rays

    International Nuclear Information System (INIS)

    Tajima, Mataichi.

    1965-01-01

    Conventional black and white X-ray photography cannot simultaneously produce an image on photographic film of a subject having regions of high and low X-ray absorption due to the limitation of photographic density range, gradation and exposure tolerance. This invention records both regions as images of different colors on the same color photographic film. According to a method of this invention for making an X-ray pseudo-color photograph, the subject is directly irradiated by an X-ray beam emergent from an X-ray beam generator, and an X-ray permeation image of the subject is converted into and displayed as a visible light image by means of a fluorescent screen. In one aspect of this invention, there is used a color photographic film which has at least two kinds of sensitive and coloring layers exhibiting the same sensitivity. During the period in which the visible image is displayed, the film is exposed to the visible light in such a way that at least two color filters differing in color and density are successively interposed between the film and the fluorescent screen. In another aspect, a color photographic film is employed having at least two kinds of sensitive and coloring layers exhibiting different sensitivities. During the period in which the visible image is displayed, the film is exposed to visible light by sequentially interposing at least two color filters of different color but of equal density. In this manner, regions comparatively low in X-ray absorption, such as the lungs, and regions comparatively high in absorption, such as the heart, appear as, for example, a blue image and a red image on the color photographic film, respectively. (Takasuka, S.)

  7. X-rays from stars

    Science.gov (United States)

    Güdel, Manuel

    2004-07-01

    Spectroscopic studies available from Chandra and XMM-Newton play a pivotal part in the understanding of the physical processes in stellar (magnetic and non-magnetic) atmospheres. It is now routinely possible to derive densities and to study the influence of ultraviolet radiation fields, both of which can be used to infer the geometry of the radiating sources. Line profiles provide important information on bulk mass motions and attenuation by neutral matter, e.g. in stellar winds. The increased sensitivity has revealed new types of X-ray sources in systems that were thought to be unlikely places for X-rays: flaring brown dwarfs, including rather old, non-accreting objects, and terminal shocks in jets of young stars are important examples. New clues concerning the role of stellar high-energy processes in the modification of the stellar environment (ionization, spallation, etc.) contribute significantly to our understanding of the "astro-ecology" in forming planetary systems. Technological limitations are evident. The spectral resolution has not reached the level where bulk mass motions in cool stars become easily measurable. Higher resolution would also be important to perform X-ray "Doppler imaging" in order to reconstruct the 3-D distribution of the X-ray sources around a rotating star. Higher sensitivity will be required to perform high-resolution spectroscopy of weak sources such as brown dwarfs or embedded pre-main-sequence sources. A new generation of satellites such as Constellation-X or XEUS should pursue these goals.

  8. Development of responder criteria for multicomponent non-pharmacological treatment in fibromyalgia.

    Science.gov (United States)

    Vervoort, Vera M; Vriezekolk, Johanna E; van den Ende, Cornelia H

    2017-01-01

    There is a need to identify individual treatment success in patients with fibromyalgia (FM) who received non-pharmacological treatment. The present study described responder criteria for multicomponent non-pharmacological treatment in FM, and estimated and compared their sensitivity and specificity. Candidate responder sets were 1) identified in literature; and 2) formulated by expert group consensus. All candidate responder sets were tested in a cohort of 129 patients with FM receiving multicomponent non-pharmacological treatment. We used two gold standards (both therapist's and patient's perspective), assessed at six months after the start of treatment. Seven responder sets were defined (three identified in literature and four formulated by expert group consensus), and comprised combinations of domains of 1) pain; 2) fatigue; 3) patient global assessment (PGA); 4) illness perceptions; 5) limitations in activities of daily living (ADL); and 6) sleep. The sensitivity and specificity of literature-based responder sets (n=3) ranged between 17%-99% and 15%-95% respectively, whereas the expert-based responder sets (n=4) performed slightly better with regard to sensitivity (range 41%-81%) and specificity (range 50%-96%). Of the literature-based responder sets the OMERACT-OARSI responder set with patient's gold standard performed best (sensitivity 63%, specificity 75% and ROC area = 0.69). Overall, the expert-based responder set comprising the domains illness perceptions and limitations in ADL with patient's gold standard performed best (sensitivity 47%, specificity 96% and ROC area = 0.71). We defined sets of responder criteria for multicomponent non-pharmacological treatment in fibromyalgia. Further research should focus on the validation of those sets with acceptable performance.

  9. Absorbed dose rate meter for β-ray

    International Nuclear Information System (INIS)

    Bingo, K.

    1977-01-01

    The absorbed dose of β-ray depends on the energy of β-rays and the epidermal thickness of tissue in interest. In order to measure the absorbed dose rate at the interested tissue directly, the ratio of counting rate to absorbed dose should be constant independent of β-ray energy. In this purpose, a thin plastic scintillator was used as a detector with a single channel analyzer. The pulse height distribution, obtained using the scintillator whose thickness is less than the range of β-rays, shows a peak at a particular pulse height depending on the thickness of scintillator used. This means an increase of the number of pulses at lower pulse height. The lower level of discrimination and window width of the single channel analyzer are chosen according to the epidermal thickness of the tissue. In the experiment, scintillators of 0.5, 1, 2, 3, 5 and 10 mm thick were tested. It was found that desirable pulse height distribution, to obtain a constant dose sensitivity, could be obtained using the 2 mm thick scintillator. The sensitivity of the absorbed dose rate meter is constant within +-15% for β-ray with maximum energy from 0.4 to 3.5 MeV, when the absorbed dose rate for skin (epidermal thickness 7mg/cm 2 ) is measured. In order to measure the dose rate for a hand (epithermal thickness 40mg/cm 2 ) the lower level of discrimination is changed to be higher and at the same time the window width is also changed. Combining these techniques, one can get an absorbed dose rate meter for the tissue dose of various thickness, which has the constant dose sensitivity within +-15% for β-rays with maximum energy from 0.4 to 3.5 MeV

  10. Diagnostic criteria for cryopyrin-associated periodic syndrome (CAPS).

    Science.gov (United States)

    Kuemmerle-Deschner, Jasmin B; Ozen, Seza; Tyrrell, Pascal N; Kone-Paut, Isabelle; Goldbach-Mansky, Raphaela; Lachmann, Helen; Blank, Norbert; Hoffman, Hal M; Weissbarth-Riedel, Elisabeth; Hugle, Boris; Kallinich, Tilmann; Gattorno, Marco; Gul, Ahmet; Ter Haar, Nienke; Oswald, Marlen; Dedeoglu, Fatma; Cantarini, Luca; Benseler, Susanne M

    2017-06-01

    Cryopyrin-associated periodic syndrome (CAPS) is a rare, heterogeneous disease entity associated with NLRP3 gene mutations and increased interleukin-1 (IL-1) secretion. Early diagnosis and rapid initiation of IL-1 inhibition prevent organ damage. The aim of the study was to develop and validate diagnostic criteria for CAPS. An innovative process was followed including interdisciplinary team building, item generation: review of CAPS registries, systematic literature review, expert surveys, consensus conferences for item refinement, item reduction and weighting using 1000Minds decision software. Resulting CAPS criteria were tested in large cohorts of CAPS cases and controls using correspondence analysis. Diagnostic models were explored using sensitivity analyses. The international team included 16 experts. Systematic literature and registry review identified 33 CAPS-typical items; the consensus conferences reduced these to 14. 1000Minds exercises ranked variables based on importance for the diagnosis. Correspondence analysis determined variables consistently associated with the diagnosis of CAPS using 284 cases and 837 controls. Seven variables were significantly associated with CAPS (pCAPS-typical symptoms: urticaria-like rash, cold-triggered episodes, sensorineural hearing loss, musculoskeletal symptoms, chronic aseptic meningitis and skeletal abnormalities. Sensitivity was 81%, specificity 94%. It performed well for all CAPS subtypes and regardless of NLRP3 mutation. The novel approach integrated traditional methods of evidence synthesis with expert consensus, web-based decision tools and innovative statistical methods and may serve as model for other rare diseases. These criteria will enable a rapid diagnosis for children and adults with CAPS. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  11. On the use of one-dimensional position sensitive detector for x-ray diffraction reciprocal space mapping: Data quality and limitations

    International Nuclear Information System (INIS)

    Masson, Olivier; Boulle, Alexandre; Guinebretiere, Rene; Lecomte, Andre; Dauger, Alain

    2005-01-01

    A homemade x-ray diffractometer using one-dimensional position sensitive detector (PSD) and well suited to the study of thin epitaxial layer systems is presented. It is shown how PSDs can be advantageously used to allow fast reciprocal space mapping, which is especially interesting when analyzing poor crystalline and defective layers as usually observed with oxides and ceramics films. The quality of the data collected with such a setup and the limitations of PSDs in comparison with the use of analyzer crystals are discussed. In particular, the effects of PSD on angular precision, instrument resolution and corrections that must be applied to raw data are presented

  12. Method of incident low-energy gamma-ray direction reconstruction in the GAMMA-400 gamma-ray space telescope

    International Nuclear Information System (INIS)

    Kheymits, M D; Leonov, A A; Zverev, V G; Galper, A M; Arkhangelskaya, I V; Arkhangelskiy, A I; Yurkin, Yu T; Bakaldin, A V; Suchkov, S I; Topchiev, N P; Dalkarov, O D

    2016-01-01

    The GAMMA-400 gamma-ray space-based telescope has as its main goals to measure cosmic γ-ray fluxes and the electron-positron cosmic-ray component produced, theoretically, in dark-matter-particles decay or annihilation processes, to search for discrete γ-ray sources and study them in detail, to examine the energy spectra of diffuse γ-rays — both galactic and extragalactic — and to study gamma-ray bursts (GRBs) and γ-rays from the active Sun. Scientific goals of GAMMA-400 telescope require fine angular resolution. The telescope is of a pair-production type. In the converter-tracker, the incident gamma-ray photon converts into electron-positron pair in the tungsten layer and then the tracks are detected by silicon- strip position-sensitive detectors. Multiple scattering processes become a significant obstacle in the incident-gamma direction reconstruction for energies below several gigaelectronvolts. The method of utilising this process to improve the resolution is proposed in the presented work. (paper)

  13. Sensitivity of photodiode detector for industrial computed tomography

    International Nuclear Information System (INIS)

    Wang Jue; Chen Jiaoze; Chen Xufeng; Tan Hui

    2012-01-01

    Studying on sensitivity of detector has most guiding significance for the selecting of X-ray Energy, the designing of detector and matching between X-ray source and detector. Several major factors of sensitivity and their quantitative relation were studied. First, factors such as energy deposition rate, absolute scintillation efficiency, light collection efficiency and photoelectrical conversion efficiency were analyzed. Then, a simulation for energy deposition rate of scintillation crystal and light collection efficiency was carried out by Monte Carlo method. The fluorescence conversion efficiency of the CsI (Tl) scintillator and the photoelectric conversion efficiency of the photoelectric diode were computed. The concept of matching between the scintillator and the photoelectric diode was defined. Finally, the sensitivity expression with universal meaning of the detector was obtained. The maximum error between theoretical value and practical measurement result is less than 20.4%. The experiments show the validity and the accuracy of the computing method of the sensitivity. (authors)

  14. Hematological findings in male x-ray technicians

    International Nuclear Information System (INIS)

    Meo, Sultan A.

    2004-01-01

    In view of the known health hazards of x-ray radiation, this study focuses on the basic hematological parameters: red blood cells (RBCs), white blood cells (WBCs) and platelets count in x-ray technicians. The aim was to identify the affect of x-ray radiation on blood cell counts in x-ray technicians. The present study was conducted in the Department of Physiology, College of Medicine, King Saud University, Riyadh, Kingdom of Saudi Arabia during the year 2002. In this study, a group of 40 apparently healthy male x-ray technicians with age ranging from 25-50-years were recruited. They were matched with another group of 40 apparently healthy control subjects in terms of age, sex and ethnic origin. Both groups met with exclusion criteria as per standard. Red blood cells, WBC and platelets count were performed by using a blood cell auto analyser. The mean value of platelet count was significantly decreased (p<0.01) in x-ray technicians when compared to controls. However, no significant difference was observed in RBC and WBC count between the groups. Radiation causes decreased platelet count. Further, studies are needed to study the long-term effects of x-ray radiation on blood cell count in x-ray technicians. (author)

  15. A conceptualisation framework for building consensus on environmental sensitivity.

    Science.gov (United States)

    González Del Campo, Ainhoa

    2017-09-15

    Examination of the intrinsic attributes of a system that render it more or less sensitive to potential stressors provides further insight into the baseline environment. In impact assessment, sensitivity of environmental receptors can be conceptualised on the basis of their: a) quality status according to statutory indicators and associated thresholds or targets; b) statutory protection; or c) inherent risk. Where none of these considerations are pertinent, subjective value judgments can be applied to determine sensitivity. This pragmatic conceptual framework formed the basis of a stakeholder consultation process for harmonising degrees of sensitivity of a number of environmental criteria. Harmonisation was sought to facilitate their comparative and combined analysis. Overall, full or wide agreement was reached on relative sensitivity values for the large majority of the reviewed criteria. Consensus was easier to reach on some themes (e.g. biodiversity, water and cultural heritage) than others (e.g. population and soils). As anticipated, existing statutory measures shaped the outcomes but, ultimately, knowledge-based values prevailed. The agreed relative sensitivities warrant extensive consultation but the conceptual framework provides a basis for increasing stakeholder consensus and objectivity of baseline assessments. This, in turn, can contribute to improving the evidence-base for characterising the significance of potential impacts. Copyright © 2017 Elsevier Ltd. All rights reserved.

  16. The Advanced Gamma-ray Imaging System (AGIS)-Simulation Studies

    Science.gov (United States)

    Maier, G.; Buckley, J.; Bugaev, V.; Fegan, S.; Funk, S.; Konopelko, A.; Vassiliev, V. V.

    2008-12-01

    The Advanced Gamma-ray Imaging System (AGIS) is a US-led concept for a next-generation instrument in ground-based very-high-energy gamma-ray astronomy. The most important design requirement for AGIS is a sensitivity of about 10 times greater than current observatories like Veritas, H.E.S.S or MAGIC. We present results of simulation studies of various possible designs for AGIS. The primary characteristics of the array performance, collecting area, angular resolution, background rejection, and sensitivity are discussed.

  17. Multichannel X-ray detectors

    Energy Technology Data Exchange (ETDEWEB)

    Khabakhpashev, A

    1980-10-01

    A typical design is discussed of multiwire proportional counters and their characteristic feature is explained, ie., the possibility of showing one or two coordinates of the X-ray quantum absorption site. The advantages of such instruments are listed, such as increased sensitivity of determination, the possibility of recording radiations of a different intensity, the possibility of on-line data processing and of the digital display of results. The fields of application include X-ray structural analysis in solid state physics, crystallography, molecular biology, astronomy, materials testing, and medicine.

  18. Retrospective analysis of 'gamma distribution' based IMRT QA criteria

    International Nuclear Information System (INIS)

    Wen, C.; Chappell, R.A.

    2010-01-01

    Full text: IMRT has been implemented into clinical practice at Royal Hobart Hospital (RHH) since mid 2006 for treating patients with Head and Neck (H and N) or prostate tumours. A local quality assurance (QA) acceptance criteria based on 'gamma distribution' for approving IMRT plan was developed and implemented in early 2007. A retrospective analysis of such criteria over 194 clinical cases will be presented. The RHH IMRT criteria was established with assumption that gamma distribution obtained through inter-comparison of 2 D dose maps between planned and delivered was governed by a positive-hail' normal distribution. A commercial system-MapCheck was used for 2 D dose map comparison with a built-in gamma analysis tool. Gamma distribution histogram was generated and recorded for all cases. By retrospectively analysing those distributions using curve fitting technique, a statistical gamma distribution can be obtained and evaluated. This analytical result can be used for future IMRT planing and treatment delivery. The analyses indicate that gamma distribution obtained through MapCheckTM is well under the normal distribution, particularly for prostate cases. The applied pass/fail criteria is not overly sensitive to identify 'false fails' but can be further tighten-up for smaller field while for larger field found in both H and N and prostate cases, the criteria was correctly applied. Non-uniform distribution of detectors in MapCheck and experience level of planners are two major factors to variation in gamma distribution among clinical cases. This criteria derived from clinical statistics is superior and more accurate than single-valued criteria for lMRT QA acceptance procedure. (author)

  19. Characteristics of charge coupled devices over X-ray spectral band

    Energy Technology Data Exchange (ETDEWEB)

    Mishenskij, V O; Volkov, G S; Zajtsev, V I; Zazhivikhin, V V [Troitsk Institute for Thermonuclear and Innovation Investigations (Russian Federation)

    1997-12-31

    The results of theoretical and experimental investigation of the sensitivity and spatial resolution of charge coupled devices (CCD) influenced by X-ray quanta are reported. Both a calculation model of the interaction process between the X-ray radiation and the CCD-structure and experimental results of investigation of the CCD characteristics are presented. The theoretical model of interaction between X-ray radiation and CCD is suggested. In accordance with the model, the calculations of CCD sensitivity and spatial resolution, depending on the X-ray energy, are performed. The results of comparison of the calculated and experimental data obtained for linear CCD (LCCD) are presented. The CCD has a maximum sensitivity of approx. (1-2.5) . 10{sup 7} V.cm{sup 2}/J for quanta of energies of 0.5-8 keV. The CCD spatial resolution varies from 15-20 {mu}m (CCD gate size) for quanta of energies less then 4 keV and deteriorates up to 150 {mu}m for harder radiation (20-50 keV). CCD usage as space-resolving detectors for high-power installation diagnostics is presented. Other fields of CCD application for X-ray detection are discussed. Advantages of CCD in comparison with the traditional X-ray films is discussed from this point of view. (author). 4 figs., 3 refs.

  20. X-ray investigations of the hot ISM

    Science.gov (United States)

    Sanders, W. T.

    1993-01-01

    At energies less than one keV, the intensity of the galactic x-ray background dominates that of the extragalactic background in almost every direction on the sky. Below 1/4 keV, the galactic x-ray background has a galactic stellar component, but the dominant emitter seems to be hot interstellar matter. The origin of the general 3/4 keV x-ray background remains uncertain, but one component must also be the contribution from hot interstellar matter. An overview is given of recent x-ray investigations of the hot interstellar medium using data from the ROSAT X-ray Telescope/Position-Sensitive Proportional Counter (XRT/PSPC) instrument. Several prominent features in the low energy x-ray background that are interpreted as fossil supernova remnants are discussed.

  1. Application of DSM-5 criteria for autism spectrum disorder to three samples of children with DSM-IV diagnoses of pervasive developmental disorders.

    Science.gov (United States)

    Huerta, Marisela; Bishop, Somer L; Duncan, Amie; Hus, Vanessa; Lord, Catherine

    2012-10-01

    Substantial revisions to the DSM-IV criteria for autism spectrum disorders (ASDs) have been proposed in efforts to increase diagnostic sensitivity and specificity. This study evaluated the proposed DSM-5 criteria for the single diagnostic category of autism spectrum disorder in children with DSM-IV diagnoses of pervasive developmental disorders (PDDs) and non-PDD diagnoses. Three data sets included 4,453 children with DSM-IV clinical PDD diagnoses and 690 with non-PDD diagnoses (e.g., language disorder). Items from a parent report measure of ASD symptoms (Autism Diagnostic Interview-Revised) and clinical observation instrument (Autism Diagnostic Observation Schedule) were matched to DSM-5 criteria and used to evaluate the sensitivity and specificity of the proposed DSM-5 criteria and current DSM-IV criteria when compared with clinical diagnoses. Based on just parent data, the proposed DSM-5 criteria identified 91% of children with clinical DSM-IV PDD diagnoses. Sensitivity remained high in specific subgroups, including girls and children under 4. The specificity of DSM-5 ASD was 0.53 overall, while the specificity of DSM-IV ranged from 0.24, for clinically diagnosed PDD not otherwise specified (PDD-NOS), to 0.53, for autistic disorder. When data were required from both parent and clinical observation, the specificity of the DSM-5 criteria increased to 0.63. These results suggest that most children with DSM-IV PDD diagnoses would remain eligible for an ASD diagnosis under the proposed DSM-5 criteria. Compared with the DSM-IV criteria for Asperger's disorder and PDD-NOS, the DSM-5 ASD criteria have greater specificity, particularly when abnormalities are evident from both parents and clinical observation.

  2. Estimating the robustness of composite CBA & MCA assessments by variation of criteria importance order

    DEFF Research Database (Denmark)

    Jensen, Anders Vestergaard; Barfod, Michael Bruhn; Leleur, Steen

    is based on the fact that when using MCA as a decision-support tool, questions often arise about the weighting (or prioritising) of the included criteria. This part of the MCA is seen as the most subjective part and could give reasons for discussion among the decision makers or stakeholders. Furthermore......This paper discusses the concept of using rank variation concerning the stake-holder prioritising of importance criteria for exploring the sensitivity of criteria weights in multi-criteria analysis (MCA). Thereby the robustness of the MCA-based decision support can be tested. The analysis described......, the relative weights can make a large difference in the resulting assessment of alternatives [1]. Therefore it is highly relevant to introduce a procedure for estimating the importance of criteria weights. This paper proposes a methodology for estimating the robustness of weights used in additive utility...

  3. Diagnostic efficiency of DSM-IV criteria for obsessive compulsive personality disorder in patients with binge eating disorder.

    Science.gov (United States)

    Grilo, C M

    2004-01-01

    This study examined the diagnostic efficiency of the DSM-IV criteria for obsessive compulsive personality disorder (OCPD) in patients with binge eating disorder (BED). Two hundred and eleven consecutive adult patients with axis I diagnoses of BED were reliably assessed with semi-structured diagnostic interviews. Conditional probabilities-sensitivity, specificity, positive predictive power (PPP), and negative predictive power (NPP)-were calculated for each of the eight criteria for OCPD, using the 'best-estimate' OCPD diagnosis as the standard. The diagnostic efficiencies of the OCPD criteria were variable, with three criteria failing to have predictive value (PPPOCPD based on performance and call into question the utility of some criteria.

  4. Validation of the MDS research criteria for prodromal Parkinson's disease: Longitudinal assessment in a REM sleep behavior disorder (RBD) cohort.

    Science.gov (United States)

    Fereshtehnejad, Seyed-Mohammad; Montplaisir, Jacques Y; Pelletier, Amelie; Gagnon, Jean-François; Berg, Daniela; Postuma, Ronald B

    2017-06-01

    Recently, the International Parkinson and Movement Disorder Society introduced the prodromal criteria for PD. Objectives Our study aimed to examine diagnostic accuracy of the criteria as well as the independence of prodromal markers to predict conversion to PD or dementia with Lewy bodies. This prospective cohort study was performed on 121 individuals with rapid eye movement sleep behavior disorder who were followed annually for 1 to 12 years. Using data from a comprehensive panel of prodromal markers, likelihood ratio and post-test probability of the criteria were calculated at baseline and during each follow-up visit. Forty-eight (39.7%) individuals with rapid eye movement sleep behavior disorder converted to PD/dementia with Lewy bodies. The prodromal criteria had 81.3% sensitivity and 67.9% specificity for conversion to PD/dementia with Lewy bodies at 4-year follow-up. One year before conversion, sensitivity was 100%. The criteria predicted dementia with Lewy bodies with even higher accuracy than PD without dementia at onset. Those who met the threshold of prodromal criteria at baseline had significantly more rapid conversion into a neurodegenerative state (4.8 vs. 9.1 years; P conversion time in a rapid eye movement sleep behavior disorder cohort, with high sensitivity and high specificity with long follow-up. Prodromal markers influence the overall likelihood ratio independently, allowing them to be reliably multiplied. Defining additional markers with high likelihood ratio, further studies with longitudinal assessment and testing thresholds in different target populations will improve the criteria. © 2017 International Parkinson and Movement Disorder Society. © 2017 International Parkinson and Movement Disorder Society.

  5. Compton scatter in germanium and its effect on imaging with gamma-ray position-sensitive detectors

    International Nuclear Information System (INIS)

    Sherman, I.S.; Strauss, M.G.; Brenner, R.

    1978-01-01

    The spatial spread due to Compton scatter in Ge was measured to study the reduction in image contrast and signal-to-noise ratio (S/N) resulting from erroneous readout in Ge position-sensitive detectors. The step response revealing this spread was obtained by scanning with a 122 keV γ-ray beam across a boundary of two sectors of a slotted coaxial Ge(Li) detector that is 40 mm diameter by 22 mm long. The derived line-spread function at 140 keV (/sup 99m/Tc) exhibits much shorter but thicker tails than those due to scatter in tissue as observed with a NaI detector through 5.5 cm of scattering material. Convolutions of rectangular profiles of voids with the Ge(Li) line-spread function show marked deterioration in contrast for voids less than 10 mm across, which in turn results in even greater deterioration of the S/N. As a result, the contrast for voids in Ge images is only 20 to 30 percent higher than that in NaI and the S/N is only comparable for equal detector areas. The degradation in image contrast due to scatter in Ge detectors can be greatly reduced by either using thin detectors (approximately 5 mm), where scatter virtually does not exist, or by using thicker detectors and rejecting scatter electronically. To reduce the effects of scatter on the S/N as well as on contrast, the erroneous position readouts must actually be corrected. A more realizable approach to achieving the ultimate potential of Ge detectors may be a scanning array of discrete detectors (not position sensitive) in which readout is not affected by scatter

  6. Action of cis-dichlorobis (cyclopentylamine) platinum (2) (cis-PAD) on L5178Y cells of two strains inversely cross-sensitive to X-rays and UV-light. Part 1. Cytotoxicity

    International Nuclear Information System (INIS)

    Szumiel, I.

    1977-01-01

    The response to cis-PAD, an antitumour platinum complex, was studied in two strains of murine lymphoma L5178Y cross-sensitive to X-rays and UV light. Dose-survival relationship, DNA synthesis, formation of chromatid aberrations, progression through the cell cycle, and growth and viability changes after 1 h cis-PAD treatment at 37 0 C were examined and compared with respective effects of X-rays and UV-light. In both strains studied, cis-PAD causes immediate inhibition of progression through the cell cycle, reduced rate of DNA synthesis, delayed appearance of chromatid aberrations and delayed death. However, there is a marked difference in sensitivity to cis-PAD between L5178Y-S strain (D 0 ca.5.8 μg/ml) and L5178Y-R strain (D 0 ca. 2.5μg/ml). In both strains a close resemblance was found between dose-survival relationship after cis-PAD and UV-light treatment, respectively. (author)

  7. Gamma-Ray Imaging Spectrometer (GRIS): a new balloon-borne experiment for gamma-ray line astronomy

    International Nuclear Information System (INIS)

    Teegarden, B.J.; Cline, T.L.; Gehrels, N.; Porreca, G.; Tueller, J.; Leventhal, M.; Huters, A.F.; Maccallum, C.J.; Stang, P.D.; Sandia Labs., Albuquerque, NM)

    1985-01-01

    High resolution gamma-ray spectroscopy is a relatively new field that holds great promise for further understanding of high energy astrophysical processes. When the high resolution gamma-ray spectrometer (GRSE) was removed from the GRO payload, a balloon program was initiated to permit continued development and improvement of instrumentation in this field, as well as continued scientific observations. The Gamma-Ray Imaging Spectrometer (GRIS) is one of the experiments selected as part of this program. The instrument contains a number of new and innovative features that are expected to produce a significant improvement in source location accuracy and sensitivity over previous balloon and satellite experiments

  8. Use of external cost assessment and multi-criteria decision analysis for comparative evaluation of options for electricity supply

    International Nuclear Information System (INIS)

    Hirschberg, S.; Dones, R.; Gantner, U.

    2001-01-01

    The paper addresses external cost and multi-criteria analyses carried out for selected future electricity generating systems of interest under the Swiss conditions. The external cost estimates are based on an application of the 'impact pathway approach', enhanced by earlier experience from extensive Life Cycle Assessment (LCA). The estimated total costs, i.e. the sum of internal and external costs, may serve as a measure of economic and environmental efficiency of energy systems. The multi-criteria approach allows a more explicit consideration of the social dimension, which is highly important for the decision-making process. The applications of multi-criteria analyses illustrate the sensitivity of the results to the range of preferences expressed in the energy debate. Certain patterns in system ranking can be observed in spite of these sensitivities. Both total cost assessment and multi-criteria analysis are found to be useful, complementary instruments to support procedures for decision-making. (author)

  9. Characteristics of the telescope for high energy gamma-ray astronomy selected for definition studies on the Gamma Ray Observatory

    Science.gov (United States)

    Hughes, E. B.; Hofstadter, R.; Rolfe, J.; Johansson, A.; Bertsch, D. L.; Cruickshank, W. J.; Ehrmann, C. H.; Fichtel, C. E.; Hartman, R. C.; Kniffen, D. A.

    1980-01-01

    The high energy gamma-ray telescope selected for definition studies on the Gamma Ray Observatory provides a substantial improvement in observational capability over earlier instruments. It will have about 20 times more sensitivity, cover a much broader energy range, have considerably better energy resolution and provide a significantly improved angular resolution. The design and performance are described.

  10. Flat Field Anomalies in an X-ray CCD Camera Measured Using a Manson X-ray Source (HTPD 08 paper)

    International Nuclear Information System (INIS)

    Haugh, M; Schneider, M B

    2008-01-01

    The Static X-ray Imager (SXI) is a diagnostic used at the National Ignition Facility (NIF) to measure the position of the X-rays produced by lasers hitting a gold foil target. The intensity distribution taken by the SXI camera during a NIF shot is used to determine how accurately NIF can aim laser beams. This is critical to proper NIF operation. Imagers are located at the top and the bottom of the NIF target chamber. The CCD chip is an X-ray sensitive silicon sensor, with a large format array (2k x 2k), 24 (micro)m square pixels, and 15 (micro)m thick. A multi-anode Manson X-ray source, operating up to 10kV and 10W, was used to characterize and calibrate the imagers. The output beam is heavily filtered to narrow the spectral beam width, giving a typical resolution E/ΔE ∼ 10. The X-ray beam intensity was measured using an absolute photodiode that has accuracy better than 1% up to the Si K edge and better than 5% at higher energies. The X-ray beam provides full CCD illumination and is flat, within ±1% maximum to minimum. The spectral efficiency was measured at 10 energy bands ranging from 930 eV to 8470 eV. We observed an energy dependent pixel sensitivity variation that showed continuous change over a large portion of the CCD. The maximum sensitivity variation occurred at 8470 eV. The geometric pattern did not change at lower energies, but the maximum contrast decreased and was not observable below 4 keV. We were also able to observe debris, damage, and surface defects on the CCD chip. The Manson source is a powerful tool for characterizing the imaging errors of an X-ray CCD imager. These errors are quite different from those found in a visible CCD imager

  11. Clinical characteristics of migraine and episodic tension-type headache in relation to old and new diagnostic criteria

    DEFF Research Database (Denmark)

    Iversen, Helle Klingenberg; Langemark, M; Andersson, P G

    1990-01-01

    Eighty-one patients were diagnosed as having migraine, tension headache or both according to previously used criteria. Then we performed a standardized interview to determine the frequency and severity of headache characteristics used in the new operational diagnostic criteria of the International...... Headache Society (IHS). In every patient the original diagnosis fulfilled also the IHS criteria, but in 9 patients the criteria were only fulfilled in half or less of the attacks, and applying the IHS criteria they also achieved an additional diagnosis. In one patient these attacks did not fulfill the pain...... criteria and in 8 (4 migraine, 4 tension headache) they did not fulfill the criteria for accompanying symptoms. Overall the IHS criteria are sensitive and specific, but they may possibly be improved with regard to accompanying symptoms. The present study suggests that recording of frequency and graded...

  12. Bi-directional x-ray phase-contrast mammography.

    Directory of Open Access Journals (Sweden)

    Kai Scherer

    Full Text Available Phase-contrast x-ray imaging is a promising improvement of conventional absorption-based mammography for early tumor detection. This potential has been demonstrated recently, utilizing structured gratings to obtain differential phase and dark-field scattering images. However, the inherently anisotropic imaging sensitivity of the proposed mono-directional approach yields only insufficient diagnostic information, and has low diagnostic sensitivity to highly oriented structures. To overcome these limitations, we present a two-directional x-ray phase-contrast mammography approach and demonstrate its advantages by applying it to a freshly dissected, cancerous mastectomy breast specimen. We illustrate that the two-directional scanning procedure overcomes the insufficient diagnostic value of a single scan, and reliably detects tumor structures, independently from their orientation within the breast. Our results indicate the indispensable diagnostic necessity and benefit of a multi-directional approach for x-ray phase-contrast mammography.

  13. On the viability of exploiting L-shell fluorescence for X-ray polarimetry

    Energy Technology Data Exchange (ETDEWEB)

    Weisskopf, M C; Elsner, R F; Ramsey, B D; Sutherland, P G

    1985-05-15

    It has been suggested that one may build an X-ray polarimeter by exploiting the polarization dependence of the angular distribution of L-shell fluorescence photons. In this paper we examine, theoretically, the sensitivity of this approach to polarimetry. We apply our calculations to several detection schemes using imaging proportional counters that would have direct application in X-ray astronomy. We find, however, that the sensitivity of this method for measuring X-ray polarization is too low to be of use for other than laboratory applications. (orig.).

  14. Quantitative Evaluation of Aged AISI 316L Stainless Steel Sensitization to Intergranular Corrosion: Comparison Between Microstructural Electrochemical and Analytical Methods

    Science.gov (United States)

    Sidhom, H.; Amadou, T.; Sahlaoui, H.; Braham, C.

    2007-06-01

    The evaluation of the degree of sensitization (DOS) to intergranular corrosion (IGC) of a commercial AISI 316L austenitic stainless steel aged at temperatures ranging from 550 °C to 800 °C during 100 to 80,000 hours was carried out using three different assessment methods. (1) The microstructural method coupled with the Strauss standard test (ASTM A262). This method establishes the kinetics of the precipitation phenomenon under different aging conditions, by transmission electronic microscope (TEM) examination of thin foils and electron diffraction. The subsequent chromium-depleted zones are characterized by X-ray microanalysis using scanning transmission electronic microscope (STEM). The superimposition of microstructural time-temperature-precipitation (TTP) and ASTM A262 time-temperature-sensitization (TTS) diagrams provides the relationship between aged microstructure and IGC. Moreover, by considering the chromium-depleted zone characteristics, sensitization and desensitization criteria could be established. (2) The electrochemical method involving the double loop-electrochemical potentiokinetic reactivation (DL-EPR) test. The operating conditions of this test were initially optimized using the experimental design method on the bases of the reliability, the selectivity, and the reproducibility of test responses for both annealed and sensitized steels. The TTS diagram of the AISI 316L stainless steel was established using this method. This diagram offers a quantitative assessment of the DOS and a possibility to appreciate the time-temperature equivalence of the IGC sensitization and desensitization. (3) The analytical method based on the chromium diffusion models. Using the IGC sensitization and desensitization criteria established by the microstructural method, numerical solving of the chromium diffusion equations leads to a calculated AISI 316L TTS diagram. Comparison of these three methods gives a clear advantage to the nondestructive DL-EPR test when it is

  15. Improvements in X-ray detectors

    International Nuclear Information System (INIS)

    Whetten, N.R.; Houston, J.M.

    1979-01-01

    Multicellular, spatially separate, gaseous ionization detectors for use in computerized tomography are described. They have high sensitivity, short recovery time, fine spatial resolution and are relatively insensitive to the adverse effects of k shell x-ray fluoresecence.(UK)

  16. 2015 Gout classification criteria: an American College of Rheumatology/European League Against Rheumatism collaborative initiative

    Science.gov (United States)

    Neogi, Tuhina; Jansen, Tim L Th A; Dalbeth, Nicola; Fransen, Jaap; Schumacher, H Ralph; Berendsen, Dianne; Brown, Melanie; Choi, Hyon; Edwards, N Lawrence; Janssens, Hein J E M; Lioté, Frédéric; Naden, Raymond P; Nuki, George; Ogdie, Alexis; Perez-Ruiz, Fernando; Saag, Kenneth; Singh, Jasvinder A; Sundy, John S; Tausche, Anne-Kathrin; Vaquez-Mellado, Janitzia; Yarows, Steven A; Taylor, William J

    2015-01-01

    Objective Existing criteria for the classification of gout have suboptimal sensitivity and/or specificity, and were developed at a time when advanced imaging was not available. The current effort was undertaken to develop new classification criteria for gout. Methods An international group of investigators, supported by the American College of Rheumatology and the European League Against Rheumatism, conducted a systematic review of the literature on advanced imaging of gout, a diagnostic study in which the presence of monosodium urate monohydrate (MSU) crystals in synovial fluid or tophus was the gold standard, a ranking exercise of paper patient cases, and a multi-criterion decision analysis exercise. These data formed the basis for developing the classification criteria, which were tested in an independent data set. Results The entry criterion for the new classification criteria requires the occurrence of at least one episode of peripheral joint or bursal swelling, pain, or tenderness. The presence of MSU crystals in a symptomatic joint/bursa (ie, synovial fluid) or in a tophus is a sufficient criterion for classification of the subject as having gout, and does not require further scoring. The domains of the new classification criteria include clinical (pattern of joint/bursa involvement, characteristics and time course of symptomatic episodes), laboratory (serum urate, MSU-negative synovial fluid aspirate), and imaging (double-contour sign on ultrasound or urate on dual-energy CT, radiographic gout-related erosion). The sensitivity and specificity of the criteria are high (92% and 89%, respectively). Conclusions The new classification criteria, developed using a data-driven and decision-analytic approach, have excellent performance characteristics and incorporate current state-of-the-art evidence regarding gout. PMID:26359487

  17. Developments in mercuric iodide gamma ray imaging

    Energy Technology Data Exchange (ETDEWEB)

    Patt, B E; Beyerle, A G; Dolin, R C; Ortale, C [EG and G Energy Measurements, Inc., Goleta, CA (USA). Santa Barbara Operations

    1989-11-01

    A mercuric iodide (HgI{sub 2}) gamma ray imaging array and camera system previously described have been characterized for spatial and energy resolution. Based on these data a new camera is being developed to more fully exploit the potential of the array. Characterization results and design criteria for the new camera will be presented. (orig.).

  18. X-Ray Optics: Past, Present, and Future

    Science.gov (United States)

    Zhang, William W.

    2010-01-01

    X-ray astronomy started with a small collimated proportional counter atop a rocket in the early 1960s. It was immediately recognized that focusing X-ray optics would drastically improve both source location accuracy and source detection sensitivity. In the past 5 decades, X-ray astronomy has made significant strides in achieving better angular resolution, large photon collection area, and better spectral and timing resolutions, culminating in the three currently operating X-ray observatories: Chandra, XMM/Newton, and Suzaku. In this talk I will give a brief history of X-ray optics, concentrating on the characteristics of the optics of these three observatories. Then I will discuss current X-ray mirror technologies being developed in several institutions. I will end with a discussion of the optics for the International X-ray Observatory that I have been developing at Goddard Space Flight Center.

  19. PROMETHEE Method and Sensitivity Analysis in the Software Application for the Support of Decision-Making

    Directory of Open Access Journals (Sweden)

    Petr Moldrik

    2008-01-01

    Full Text Available PROMETHEE is one of methods, which fall into multi-criteria analysis (MCA. The MCA, as the name itself indicates, deals with the evaluation of particular variants according to several criteria. Developed software application (MCA8 for the support of multi-criteria decision-making was upgraded about PROMETHEE method and a graphic tool, which enables the execution of the sensitivity analysis. This analysis is used to ascertain how a given model output depends upon the input parameters. The MCA8 software application with mentioned graphic upgrade was developed for purposes of solving multi-criteria decision tasks. In the MCA8 is possible to perform sensitivity analysis by a simple form – through column graphs. We can change criteria significances (weights in these column graphs directly and watch the changes of the order of variants immediately.

  20. Testing the validity and acceptability of the diagnostic criteria for Hoarding Disorder: a DSM-5 survey.

    Science.gov (United States)

    Mataix-Cols, D; Fernández de la Cruz, L; Nakao, T; Pertusa, A

    2011-12-01

    The DSM-5 Obsessive-Compulsive Spectrum Sub-Workgroup is recommending the creation of a new diagnostic category named Hoarding Disorder (HD). The validity and acceptability of the proposed diagnostic criteria have yet to be formally tested. Obsessive-compulsive disorder/hoarding experts and random members of the American Psychiatric Association (APA) were shown eight brief clinical vignettes (four cases meeting criteria for HD, three with hoarding behaviour secondary to other mental disorders, and one with subclinical hoarding behaviour) and asked to decide the most appropriate diagnosis in each case. Participants were also asked about the perceived acceptability of the criteria and whether they supported the inclusion of HD in the main manual. Altogether, 211 experts and 48 APA members completed the survey (30% and 10% response rates, respectively). The sensitivity and specificity of the HD diagnosis and the individual criteria were high (80-90%) across various types of professionals, irrespective of their experience with hoarding cases. About 90% of participants in both samples thought the criteria would be very/somewhat acceptable for professionals and sufferers. Most experts (70%) supported the inclusion of HD in the main manual, whereas only 50% of the APA members did. The proposed criteria for HD have high sensitivity and specificity. The criteria are also deemed acceptable for professionals and sufferers alike. Training of professionals and the development and validation of semi-structured diagnostic instruments should improve diagnostic accuracy even further. A field trial is now needed to confirm these encouraging findings with real patients in real clinical settings.

  1. Charged particle induced energy dispersive X-ray analysis

    International Nuclear Information System (INIS)

    Johansson, S.A.E.

    1979-01-01

    This review article deals with the X-ray emission induced by heavy, charged particles and the use of this process as an analytical method (PIXE). The physical processes involved, X-ray emission and the various reactions contributing to the background, are described in some detail. The sensitivity is calculated theoretically and the results compared with practical experience. A discussion is given on how the sensitivity can be optimized. The experimental arrangements are described and the various technical problems discussed. The analytical procedure, especially the sample preparation, is described in considerable detail. A number of typical practical applications are discussed. (author)

  2. Methods for reducing ghost rays on the Wolter-I focusing figures of the FOXSI rocket payload

    Science.gov (United States)

    Buitrago-Casas, Juan Camilo; Glesener, Lindsay; Christe, Steven; Ramsey, Brian; Elsner, Ronald; Courtade, Sasha; Vievering, Juliana; Subramania, Athiray; Krucker, Sam; Bale, Stuart

    2017-08-01

    In high energy solar astrophysics, imaging hard X-rays by direct focusing offers higher dynamic range and greater sensitivity compared to past techniques that used indirect imaging. The Focusing Optics X-ray Solar Imager (FOXSI) is a sounding rocket payload which uses seven sets of nested Wolter-I figured mirrors that, together with seven high-sensitive semiconductor detectors, observes the Sun in hard X-rays by direct focusing. The FOXSI rocket has successfully flown twice and is funded to fly a third time in summer 2018.The Wolter-I geometry consists of two consecutive mirrors, one paraboloid, and one hyperboloid, that reflect photons at grazing angles. Correctly focused X-rays reflect twice, once per mirror segment. For extended sources, like the Sun, off-axis photons at certain incident angles can reflect on only one mirror and still reach the focal plane, generating a pattern of single-bounce photons, or ‘ghost rays’ that can limit the sensitivity of the observation of focused X-rays. Understanding and cutting down the ghost rays on the FOXSI optics will maximize the instrument’s sensitivity of the solar faintest sources for future flights. We present an analysis of the FOXSI ghost rays based on ray-tracing simulations, as well as the effectiveness of different physical strategies to reduce them.

  3. Large area two dimensional position sensitive detectors

    International Nuclear Information System (INIS)

    Sann, H.; Olmi, A.; Lynen, U.; Stelzer, H.; Gobbi, A.; Bock, R.

    1979-02-01

    After an introduction, a position-sensitive ionization chamber, a parallel-plate detector, and a multiwire position-sensitive chamber are described. Then the data acquisition and analysis methods are considered. Furthermore, the experimental methods for a multi-parameter experiment are described. Finally, the measurement of gamma-ray and neutron multiplicities and sequential fission is considered, and the results are presented. (HSI) [de

  4. The Sun's X-ray Emission During the Recent Solar Minimum

    Science.gov (United States)

    Sylwester, Janusz; Kowalinski, Mirek; Gburek, Szymon; Siarkowski, Marek; Kuzin, Sergey; Farnik, Frantisek; Reale, Fabio; Phillips, Kenneth J. H.

    2010-02-01

    The Sun recently underwent a period of a remarkable lack of major activity such as large flares and sunspots, without equal since the advent of the space age a half century ago. A widely used measure of solar activity is the amount of solar soft X-ray emission, but until recently this has been below the threshold of the X-ray-monitoring Geostationary Operational Environmental Satellites (GOES). There is thus an urgent need for more sensitive instrumentation to record solar X-ray emission in this range. Anticipating this need, a highly sensitive spectrophotometer called Solar Photometer in X-rays (SphinX) was included in the solar telescope/spectrometer TESIS instrument package on the third spacecraft in Russia's Complex Orbital Observations Near-Earth of Activity of the Sun (CORONAS-PHOTON) program, launched 30 January 2009 into a near-polar orbit. SphinX measures X-rays in a band similar to the GOES longer-wavelength channel.

  5. Streaked, x-ray-transmission-grating spectrometer

    International Nuclear Information System (INIS)

    Ceglio, N.M.; Roth, M.; Hawryluk, A.M.

    1981-08-01

    A free standing x-ray transmission grating has been coupled with a soft x-ray streak camera to produce a time resolved x-ray spectrometer. The instrument has a temporal resolution of approx. 20 psec, is capable of covering a broad spectral range, 2 to 120 A, has high sensitivity, and is simple to use requiring no complex alignment procedure. In recent laser fusion experiments the spectrometer successfully recorded time resolved spectra over the range 10 to 120 A with a spectral resolving power, lambda/Δlambda of 4 to 50, limited primarily by source size and collimation effects

  6. Handbook on simultaneous x-ray and γ-ray ion beam methods for fine particle analysis

    International Nuclear Information System (INIS)

    Cohen, D.D.

    2000-01-01

    Sampling, measurement, characterisation and source appointment of fine atmospheric particles has become increasingly important in recent times. This is due in part to the realisation that the fine particle pollution caused by anthropogenic activities plays a key role in certain aspects of human health, pollution transport and global climate change. This publication discusses accelerator based ion beam analysis (IBA) methods of particle induced X-ray emission (PIXE) and particle induced γ-ray emission (PIGE) as applied to aerosol analysis. These techniques are sensitive, multielemental, mainly non-destructive, require no sample preparation, have short analysis times and can be used to analyse hundreds of filter samples a day in batch processing with minimum operator interaction. The aspects discussed in the publication include: the basics of the techniques; spectrum analysis; system calibration and blank subtraction; quantification; sensitivity; measurement errors

  7. Applicability of McDonald 2010 and Magnetic Resonance Imaging in Multiple Sclerosis (MAGNIMS) 2016 Magnetic Resonance Imaging Criteria for the Diagnosis of Multiple Sclerosis in Sri Lanka.

    Science.gov (United States)

    Gamage, Sujani Madhurika Kodagoda; Wijeweera, Indunil; Wijesinghe, Priyangi; Adikari, Sanjaya Bandara; Fink, Katharina; Sominanda, Herath Mudiyanselage Ajith

    2018-05-31

    The magnetic resonance imaging in multiple sclerosis (MAGNIMS) group recently proposed guidelines to replace the existing dissemination-in-space criteria in McDonald 2010 magnetic resonance imaging (MRI) criteria for diagnosing multiple sclerosis. There has been insufficient research regarding their applicability in Asians. Objective of this study was to determine the sensitivity, specificity, accuracy, positive predictive value (PPV), and negative predictive value (NPV) of McDonald 2010 and MAGNIMS 2016 MRI criteria with the aim of verifying their applicability in Sri Lankan patients. Patients with clinically isolated syndrome diagnosed by consultant neurologists were recruited from five major neurology centers. Baseline and follow-up MRI scans were performed within 3 months from the initial presentation and at one year after baseline MRI, respectively. McDonald 2010 and MAGNIMS 2016 MRI criteria were applied to all MRI scans. Patients were followed-up for 2 years to assess the conversion to clinically definite multiple sclerosis (CDMS). The sensitivity, specificity, accuracy, PPV, and NPV for predicting the conversion to CDMS were calculated. Forty-two of 66 patients converted to CDMS. Thirty-seven fulfilled the McDonald 2010 MRI criteria, and 33 converted to CDMS. MAGNIMS 2016 MRI criteria were fulfilled by 29, with 28 converting to CDMS. The sensitivity, specificity, accuracy, PPV, and NPV were 78%, 83%, 64%, 89%, and 69%, respectively, for the McDonald 2010 criteria, and 67%, 96%, 77%, 96%, and 62% for the MAGNIMS 2016 MRI criteria. MAGNIMS 2016 MRI criteria were superior to McDonald 2010 MRI criteria in specificity, accuracy, and PPV, but inferior in sensitivity and NPV. Copyright © 2018 Korean Neurological Association.

  8. Fat to muscle ratio measurements with dual energy x-ray absorbtiometry

    Energy Technology Data Exchange (ETDEWEB)

    Chen, A. [Shenzhen College of International Education, 1st HuangGang Park St., Shenzhen, GuangDong (China); Luo, J. [Department of Biomedical Engineering, University at Buffalo, 332 Bonner Hall, Buffalo, NY 14260-1920 (United States); Wang, A. [Department of Computer Science, Carnegie Mellon University, Pittsburgh, PA 15213 (United States); Broadbent, C. [School of Engineering, Columbia University, 1130 Amsterdam Av., New York, NY 10027 (United States); Zhong, J. [Department of English, Dartmouth College, 6032 Sanborn House, Hanover, NH 03755 (United States); Dilmanian, F.A. [Departments of Radiation Oncology, Neurology, and Radiology, Stony Brook University, Stony Brook, NY 11794 (United States); Zafonte, F.; Zhong, Z. [National Synchrotron Light Source II, Brookhaven National Laboratory, Bldg. 743, Upton, NY 11973 (United States)

    2015-07-11

    Accurate measurement of the fat-to-muscle ratio in animal model is important for obesity research. An efficient way to measure the fat to muscle ratio in animal model using dual-energy absorptiometry is presented in this paper. A radioactive source exciting x-ray fluorescence from a target material is used to provide the two x-ray energies needed. The x-rays, after transmitting through the sample, are measured with an energy-sensitive Ge detector. Phantoms and specimens were measured. The results showed that the method was sensitive to the fat to muscle ratios with good linearity. A standard deviation of a few percent in the fat to muscle ratio could be observed with the x-ray dose of 0.001 mGy.

  9. Position-sensitive superconductor detectors

    International Nuclear Information System (INIS)

    Kurakado, M.; Taniguchi, K.

    2016-01-01

    Superconducting tunnel junction (STJ) detectors and superconducting transition- edge sensors (TESs) are representative superconductor detectors having energy resolutions much higher than those of semiconductor detectors. STJ detectors are thin, thereby making it suitable for detecting low-energy X rays. The signals of STJ detectors are more than 100 times faster than those of TESs. By contrast, TESs are microcalorimeters that measure the radiation energy from the change in the temperature. Therefore, signals are slow and their time constants are typically several hundreds of μs. However, TESs possess excellent energy resolutions. For example, TESs have a resolution of 1.6 eV for 5.9-keV X rays. An array of STJs or TESs can be used as a pixel detector. Superconducting series-junction detectors (SSJDs) comprise multiple STJs and a single-crystal substrate that acts as a radiation absorber. SSJDs are also position sensitive, and their energy resolutions are higher than those of semiconductor detectors. In this paper, we give an overview of position-sensitive superconductor detectors.

  10. Next Generation X-ray Polarimeter

    Science.gov (United States)

    Hill-Kittle, Joe

    The emission regions of many types of X-ray sources are small and cannot be spatially resolved without interferometry techniques that haven't yet been developed. In order to understand the emission mechanisms and emission geometry, alternate measurement techniques are required. Most microphysical processes that affect X-rays, including scattering and magnetic emission processes are imprinted as polarization signatures. X-ray polarization also reveals exotic physical processes occurring in regions of very strong gravitational and magnetic fields. Observations of X-ray polarization will provide a measurement of the geometrical distribution of gas and magnetic fields without foreground depolarization that affects longer wavelengths (e.g. Faraday rotation in the radio). Emission from accretion disks has an inclination-dependent polarization. The polarization signature is modified by extreme gravitational forces, which bend light, essentially changing the contribution of each part of the disk to the integrated total intensity seen by distant observers. Because gravity has the largest effect on the innermost parts of the disk (which are the hottest, and thus contributes to more high energy photons), the energy dependent polarization is diagnostic of disk inclination, black hole mass and spin. Increasing the sensitive energy band will make these measurements possible. X-ray polarimetry will also enable the study of the origin of cosmic rays in the universe, the nature of black holes, the role of black holes in the evolution of galaxies, and the interaction of matter with the highest physically possible magnetic fields. These objectives address NASA's strategic interest in the origin, structure, and evolution of the universe. We propose a two-year effort to develop the Next Generation X-ray Polarimeter (NGXP) that will have more than ten times the sensitivity of the current state of the art. NGXP will make possible game changing measurements of classes of astrophysical

  11. Criteria for grant with the bonus for working with X-rays or radioactive substances at a federal government university

    International Nuclear Information System (INIS)

    Moro, J. Tullio; Silva, Maria T.X.; Tessler, Jacques; Niederauer, Marco A.C.

    2011-01-01

    Aiming the actualization of the criteria used for grant the 'Gratificacao por trabalhos com Raios X ou substancias radioativas' at a federal government, the administration of personnel constituted a work staff formed by the Work Safety Division and by Radiological Protection Service of the Federal University of Rio Grande do Sul - Brazil. Based on the periodical evaluation of the safety and radiological protection at the work environment and the criteria study of legislation involved in the matter, the work staff established a set of criteria approaching the specificities of the activities developed with ionizing radiation generators at the environment of that University

  12. γ-ray spectroscopy of N=Z nuclei

    International Nuclear Information System (INIS)

    Lister, C. J.

    1999-01-01

    The use of γ-ray spectroscopy to probe the properties of marginally bound nuclear states has evolved from being a curiosity a decade ago to being the mainstream use for these devices. The key to this success has been the development of ultra-sensitive channel selection techniques which allow the parentage of each emitted γ-ray to be established. With these techniques, and the enhanced efficiency of the arrays themselves, the level of sensitivity for nuclear spectroscopy has increased by several orders of magnitude, in some special cases reaching the 10's nanobarns level, 1000 times more sensitive than was possible a decade ago. In this paper I will discuss some recent developments in light nuclear spectroscopy, on nuclei with N=Z, below mass 100. These examples have been chosen to compliment other presentations at this conference which have covered similar experiments in heavier nuclei

  13. Characterization of MMS-sensitive mutants of Neurospora crassa

    Energy Technology Data Exchange (ETDEWEB)

    DeLange, A.M.; Mishra, N.C.

    1982-01-01

    Several MMS-sensitive mutants of Neurospora crassa were compared with the wild-type strain for their relative sensitivities to UV, X-ray, and histidine. They were also compared for the frequency of spontaneous mutation at the loci which confer resistance to p-fluorophenylalanine. The mutants were also examined for possible defects in meiotic behavior in homozygous crosses and for any change in the inducible DNA salvage pathways. On the basis of these characterizations, the present MMS-sensitive mutants of Neurospora can be placed into three groups. On the basis of data presented, the MMS sensitivity of the first group mutants cannot be ascertained to arise from a defect in the DNA repair pathways; instead, it may stem from altered cell permeability or other pleotropic effects of the mus mutations. However, it can be suggested that the second and third group of mus mutants may indeed result from a defect in the DNA repair pathways controlled by the mus genes; this conclusion is based on their cross-sensitivity to a number of DNA-damaging agents such as MMS, UV and/or X-rays, high frequencies of spontaneous mutation and defects in meiotic behavior.

  14. X-ray sensitivity of human tumor cells in vitro

    International Nuclear Information System (INIS)

    Weichselbaum, R.R.; Nove, J.; Little, J.B.

    1980-01-01

    Clonally-derived cells from ten human malignant tumors considered radiocurable (breast, neuroblastoma, medulloblastoma) or non-radiocurable (osteosarcoma, hypernephroma, glioblastoma, melanoma) were studied in cell culture and their in vitro x-ray survival curve parameters determined (anti n, D 0 ). There were no significant differences among the tumor cell lines suggesting that survival parameters in vitro do not explain differences in clinical radiocurability. Preliminary investigation with density inhibited human tumor cells indicate that such an approach may yield information regarding inherent cellular differences in radiocurability

  15. Field-testing of the ICHD-3 beta diagnostic criteria for classical trigeminal neuralgia

    DEFF Research Database (Denmark)

    Maarbjerg, Stine; Sørensen, Morten Togo; Gozalov, Aydin

    2015-01-01

    INTRODUCTION: We aimed to field-test the beta version of the third edition of the International Classification of Headache Disorders (ICHD-3 beta) diagnostic criteria for classical trigeminal neuralgia (TN). The proposed beta draft of the 11th version of the International Classification of Diseases...... (ICD-11 beta) is almost exclusively based on the ICHD-3 beta classification structure although slightly abbreviated. We compared sensitivity and specificity to ICHD-2 criteria, and evaluated the needs for revision. METHODS: Clinical characteristics were systematically and prospectively collected from...

  16. BaFCl:Eu2+, a new phosphor for X-ray-intensifying screens

    International Nuclear Information System (INIS)

    Stevels, A.L.N.; Pingault, F.

    1975-01-01

    A number of phosphors for X-ray-intensifying screens have been evaluated by calculating figures of merit. On use in combination with standard (''blue''-sensitive) X-ray film, BaFCl:Eu 2+ and BaFBr:Eu 2+ give better performance than the traditional CaWO 4 and more recently developed UV or blue-emitting materials (e.g., sulphates and y-oxysulphides). The calculated figures of merit of BaFCl:Eu 2+ or BaFBr:Eu 2+ /standard-film combinations are comparable to those of Gd 2 O 2 S:Tb/green-sensitive X-ray film systems. The preparation of optimal fluorohalide:Eu 2+ phosphors involves proper formation of the host lattice, complete reduction of Eu 3+ ions as well as elimination of afterglow. Measurements on powders and experimental screens indicate that by using BaFCl:Eu 2+ screens in radiography, important dose reductions can be achieved without the necessity of using other than standard (''blue''-sensitive) X-ray films

  17. A position sensitive gamma-ray detector which employs photodiode and CsI (T1) crystals

    International Nuclear Information System (INIS)

    Dean, A.J.; Graham, G.; Hopkins, C.J.; Ramsden, D.; Lei, M.

    1987-01-01

    A compact CsI(Tl)/photodiode gamma-ray detector is described which is capable of locating the point of interaction of incident gamma-ray photons in the spectral region around 1 MeV. Laboratory tests are used to quantify both the spectral and positional resolutions of the detectors. Their likely application in space gamma-ray astronomy is also discussed

  18. Physical-technical quality control for medical x-ray apparatus

    International Nuclear Information System (INIS)

    Aalbers, A.H.L.

    1989-01-01

    The technical aspects of quality control in medial x-ray diagnostics are discussed. It is recommended to hurry, also in the Netherlands, on the basis of already existing starting-up's abroad, with drawing up quality standards and judgement criteria. (author). 6 refs.; 2 figs.; 1 tab

  19. Development of a micro-X-ray fluorescence system based on polycapillary X-ray optics for non-destructive analysis of archaeological objects

    Science.gov (United States)

    Cheng, Lin; Ding, Xunliang; Liu, Zhiguo; Pan, Qiuli; Chu, Xuelian

    2007-08-01

    A new micro-X-ray fluorescence (micro-XRF) system based on rotating anode X-ray generator and polycapillary X-ray optics has been set up in XOL Lab, BNU, China, in order to be used for analysis of archaeological objects. The polycapillary X-ray optics used here can focus the primary X-ray beam down to tens of micrometers in diameter that allows for non-destructive and local analysis of sub-mm samples with minor/trace level sensitivity. The analytical characteristics and potential of this micro-XRF system in archaeological research are discussed. Some described uses of this instrument include studying Chinese ancient porcelain.

  20. Development of a micro-X-ray fluorescence system based on polycapillary X-ray optics for non-destructive analysis of archaeological objects

    Energy Technology Data Exchange (ETDEWEB)

    Cheng Lin [Key Laboratory of Beam Technology and Material Modification of Ministry of Education, Institute of Low Energy Nuclear Physics, Beijing Normal University, Beijing Radiation Center, Beijing, 100875 (China)], E-mail: chenglin@bnu.edu.cn; Ding Xunliang; Liu Zhiguo; Pan Qiuli; Chu Xuelian [Key Laboratory of Beam Technology and Material Modification of Ministry of Education, Institute of Low Energy Nuclear Physics, Beijing Normal University, Beijing Radiation Center, Beijing, 100875 (China)

    2007-08-15

    A new micro-X-ray fluorescence (micro-XRF) system based on rotating anode X-ray generator and polycapillary X-ray optics has been set up in XOL Lab, BNU, China, in order to be used for analysis of archaeological objects. The polycapillary X-ray optics used here can focus the primary X-ray beam down to tens of micrometers in diameter that allows for non-destructive and local analysis of sub-mm samples with minor/trace level sensitivity. The analytical characteristics and potential of this micro-XRF system in archaeological research are discussed. Some described uses of this instrument include studying Chinese ancient porcelain.

  1. Estimating the Robustness of Composite CBA and MCDA Assessments by Variation of Criteria Importance Order

    DEFF Research Database (Denmark)

    Jensen, Anders Vestergaard; Barfod, Michael Bruhn; Leleur, Steen

    2011-01-01

    described is based on the fact that when using MCA as a decision-support tool, questions often arise about the weighting (or prioritising) of the included criteria. This part of the MCA is seen as the most subjective part and could give reasons for discussion among the decision makers or stakeholders......Abstract This paper discusses the concept of using rank variation concerning the stakeholder prioritising of importance criteria for exploring the sensitivity of criteria weights in multi-criteria analysis (MCA). Thereby the robustness of the MCA-based decision support can be tested. The analysis....... Furthermore, the relative weights can make a large difference in the resulting assessment of alternatives (Hobbs and Meier 2000). Therefore it is highly relevant to introduce a procedure for estimating the importance of criteria weights. This paper proposes a methodology for estimating the robustness...

  2. Imaging escape gated MPWC for hard X-ray astronomy

    Energy Technology Data Exchange (ETDEWEB)

    Ubertini, P.; Bazzano, A.; Boccaccini, L.; La Padula, C.; Mastropietro, M.; Patriarca, R.; Polcaro, V.F.; Barbareschi, L.; Perotti, F.; Villa, G.

    1983-11-15

    A scientific forward step in the hard X-ray and soft gamma-ray astronomy will only be possible with the use of a new generation of space borne instruments. Their main characteristics have to be the two-dimensional imaging capability over a large collecting area and the fine spectral resolution in order to discriminate between the weak signal coming from cosmic sources to be detected and the strong background induced by cosmic rays, in the space environment, on the detector. To reach this goal we have developed a new hard X-ray position sensitive proportional counter operating with the escape gate technique in the range 15-150 keV, to be used together with a pseudo-random coded mask in order to obtain sky images. The detector is a high pressure (5 bar) xenon-argon-isobutane filled chamber with a spatial resolution of 30x2 mm and a spectral resolution of 5% at 60 keV on the sensitive area of 3000 cm/sup 2/.

  3. Time resolved x-ray pinhole photography of compressed laser fusion targets

    International Nuclear Information System (INIS)

    Attwood, D.T.

    1976-01-01

    Use of the Livermore x-ray streak camera to temporally record x-ray pinhole images of laser compressed targets is described. Use is made of specially fabricated composite x-ray pinholes which are near diffraction limited for 6 A x-rays, but easily aligned with a He--Ne laser of 6328 A wavelength. With a 6 μm x-ray pinhole, the overall system can be aligned to 5 μm accuracy and provides implosion characteristics with space--time resolutions of approximately 6 μm and 15 psec. Acceptable criteria for pinhole alignment, requisite x-ray flux, and filter characteristics are discussed. Implosion characteristics are presented from our present experiments with 68 μm diameter glass microshell targets and 0.45 terawatt, 70 psec Nd laser pulses. Final implosion velocities in excess of 3 x 10 7 cm/sec are evident

  4. A low power x-ray tube for use in energy dispersive x-ray fluorescence analysis

    International Nuclear Information System (INIS)

    Kataria, S.K.; Govil, Rekha; Lal, M.

    1980-01-01

    A low power X-ray tube with thin molybdenum transmission target for use in energy dispersive X-ray fluorescence (ENDXRF) element analysis has been indigenously built, along with its power supply. The X-ray tube has been in operation since August 1979, and it has been operated upto maximum target voltage of 35 KV and tube current upto 200 μA which is more than sufficient for trace element analysis. This X-ray tube has been used alongwith the indigenously built Si(Li) detector X-ray spectrometer with an energy resolution of 200 eV at 5.9 Kev MnKsub(α) X-ray peak for ENDXRF analysis. A simple procedure of calibration has been developed for thin samples based on the cellulose diluted, thin multielement standard pellets. Analytical sensitivities of the order of a few p.p.m. have been obtained with the experimental setup for elements with 20 < = Z < = 38 and 60 < = Z < = 90. A number of X-ray spectra for samples of environmental, biological, agricultural, industrial and metallurgical interest are presented to demonstrate the salient features of the experimental sep up. (auth.)

  5. [Genetic control of the sensitivity of Aspergillus nidulans to mutagenic factors. VII. Inheritance of cross-sensitivity to different mutagenic factors by uvs-mutants].

    Science.gov (United States)

    Evseeva, G V; Kameneva, S V

    1977-01-01

    To study the inheritance of the sensitivity to UV, X-rays, methylmethanesulphonate (MMS), nitrosoguanidine (NG) and nitrous acid (NA) in five uvs mutants of Aspergillus nidulans, having multiple sensitivity to these factors, the sensitivity of recombinants obtained from crossing uvs mutants with uvs+ strain, resistant to all the factors analysed, and uvs leads to uvs+ revertants is investigated. Four uvs mutants (15, 17, 19 and 26) are found to have a nomogenic control of sensitivity to different mutagens. In one mutant (uvs11) the sensitivity to five factors is controlled by two non-linked mutations, one of them determining the sensitivity to UV, NG, NA, and the other--to X-rays and MMC. Phenotypic manifestations of uvs mutations is modified by cell genotype, both chromosomal and cytoplasmic factors being responsible for the modification. Phenotypic modification of uvs mutation results in the change to some (but not to all) mutagenic factors. It suggests, that not the product of uvs gene, but some other components of the reparation complex are modified. Otherwise, reparation of different DNA damages can be carried out by a single enzyme acting in different reparation complexes.

  6. X-ray imaging bilinear staggered GaAs detectors

    Energy Technology Data Exchange (ETDEWEB)

    Achmadullin, R.A.; Dvoryankin, V.F. E-mail: vfd217@ire216.msk.su; Dvoryankina, G.G.; Dikaev, Y.M.Yu.M.; Krikunov, A.I.; Kudryashov, A.A.; Panova, T.M.; Petrov, A.G.; Telegin, A.A

    2004-09-21

    The multichannel bilinear X-ray detector based on epitaxial GaAs structures is developed to obtain a digital X-ray image. Each detector operates in photovoltaic mode without reverse bias that enables almost complete elimination of detector noise arising due to leakage currents. The sensitivity range of the epitaxial GaAs photovoltaic X-ray detector covers the effective energies from 8 to 120 keV. A maximum response of the detector operating in the short-circuit mode was observed at an energy of 35 keV and amounted to 30 {mu}A min/(Gy cm{sup 2}). The multichannel detector was made of 1024 pixels with pitch of 0.8 mm. The spatial resolution of double staggered sensor row is twice as high as the resolution of that of single sensor row with the same pitch. Measured spatial resolution is 1.2 line-pairs/mm, contrast sensitivity not worse 1% and dynamic range defined as the ratio of maximum detectable X-ray signal to electronic noise level more than 2000 are received.

  7. X-ray imaging bilinear staggered GaAs detectors

    International Nuclear Information System (INIS)

    Achmadullin, R.A.; Dvoryankin, V.F.; Dvoryankina, G.G.; Dikaev, Y.M.Yu.M.; Krikunov, A.I.; Kudryashov, A.A.; Panova, T.M.; Petrov, A.G.; Telegin, A.A.

    2004-01-01

    The multichannel bilinear X-ray detector based on epitaxial GaAs structures is developed to obtain a digital X-ray image. Each detector operates in photovoltaic mode without reverse bias that enables almost complete elimination of detector noise arising due to leakage currents. The sensitivity range of the epitaxial GaAs photovoltaic X-ray detector covers the effective energies from 8 to 120 keV. A maximum response of the detector operating in the short-circuit mode was observed at an energy of 35 keV and amounted to 30 μA min/(Gy cm 2 ). The multichannel detector was made of 1024 pixels with pitch of 0.8 mm. The spatial resolution of double staggered sensor row is twice as high as the resolution of that of single sensor row with the same pitch. Measured spatial resolution is 1.2 line-pairs/mm, contrast sensitivity not worse 1% and dynamic range defined as the ratio of maximum detectable X-ray signal to electronic noise level more than 2000 are received

  8. Physico technical conditions of X-ray study on the Russian X-ray diagnostic complexes Medics-R and Telemedics-R

    International Nuclear Information System (INIS)

    Blinov, N.N.; Blinov, N.M. ml

    1999-01-01

    The exposure tables developed on the basis of technical tests and experience in applying new foreign X-ray films in combination with the national calcium-tungstate (TIS) and yttrium (YIS) intensification screens are proposed for the purpose of establishing the image electrical parameters (voltage and the X-ray tube current, exposure time) by certain geometry of the roentgenological study at the Medics-R and Telemedics-R complexes (focus, focal distance, raster-, screen- and film type). The difference in the screens sensitivity by work with the green-sensitive films depending on the anode voltage applied constitutes 2.5 (40-60 kV) up to 1.8 (above 60 kV). Attention is also paid to application of automatic means [ru

  9. Gamma Ray Burst Discoveries with the Swift Mission

    Science.gov (United States)

    Gehrels, Neil; Tueller, Jack

    2007-01-01

    There is a great synergy between the Swift and INTEGRAL missions. Swift provides wide-field hard x-ray monitoring and sensitive x-ray and UV/optical observations. INTEGRAL provides optical through gamma-ray coverage with emphasis on hard xray imaging and gamma-ray spectroscopy. For hard x-ray survey studies, the BAT and IBIS instruments are complementary with BAT covering the full sky every day and IBIS scanning the galactic plane. For GRBs, Swift follows up bursts detected by INTEGRAL. X-ray and optical observations give arcsecond positions and afterglow lightcurves. For IGR sources, X-ray observations identify counterparts. The joint BAT and IBIS survey data are giving the most complete picture of the hard x-ray sky ever obtained. This talk will review Swift capabilities and discuss joint observations that are taking place and planned

  10. RI-60TK X-ray television introscope

    International Nuclear Information System (INIS)

    Zhdanov, A.V.; Shablov, S.V.; Morgunov, V.I.

    1985-01-01

    X-ray television introscope is briefly described. It is applied for remote viewing of welded joints and steel articles with up to 45 mm wall thickness, steel casting, articles of titanium and aluminium alloys. X-radiation penetrating the constrolled material is amplified by X-ray image converter and is passed to television camera tube. X-ray image is observed on the screen of picture monitor. Camera attachment is provided for document recording. The introscope possesses higher sensitivity and operates with lower dose rate of radiation as compared to earlier produced devices

  11. Dental X-ray diagnostic facility with means to choose the time of exposure

    Energy Technology Data Exchange (ETDEWEB)

    Krause, H; Grassme, U

    1978-02-16

    Equipment for dental X-ray diagnostics with automatic exposure control. In the patient's mouth there is arranged a film carrier containing in a pocket a dental X-ray film. A detector-transmitter assembly touches the pocket. It reacts to the density of the film and wireless transmits a signal to an antenna. This antenna is connected to a receiver shutting off the high voltage of the X-ray tube by means of a circuit if a desired dose value is reached. The detector-transmitter unit is an integrated component. It has got a luminescent layer with a light-sensitive detector or a detector directly sensitive to X-rays.

  12. Rhodium(III) as a potentiator of the effects of X-rays on cells

    Energy Technology Data Exchange (ETDEWEB)

    Richmond, R C; Centilli, M A; Cross, M H; Powers, E L

    1986-08-01

    A rhodium compound, Rh(NH/sub 3/)/sub 3/Cl/sub 3/, does not sensitize the spores of Bacillus megaterium to X-rays. However, it is a very effective sensitizer of vegetative cells of Staphylococcus aureus, raising the sensitivity four times in O/sub 2/ and over 100 times in anoxia. The inhibition by oxygen of the sensitizing action of Rh(III), which operates over a wide range of (O/sub 2/), is noteworthy. These experiments were performed in saline-phosphate buffer using 50 kVp X-rays. The results are discussed in terms of the known radiation chemistry of this compound.

  13. X-ray imaging with monochromatic synchrotron radiation. Fluorescent and phase-contrast method

    Energy Technology Data Exchange (ETDEWEB)

    Takeda, Tohoru; Itai, Yuji [Tsukuba Univ., Ibaraki (Japan). Inst. of Clinical Medicine

    2002-05-01

    To obtain the high sensitive x-ray images of biomedical object, new x-ray imaging techniques using fluorescent x-ray and phase-contrast x-ray are being developed in Japan. Fluorescent x-ray CT can detect very small amounts of specific elements in the order of ppm at one pixel, whereas phase-contrast x-ray imaging with interferometer can detect minute differences of biological object. Here, our recent experimental results are presented. (author)

  14. X-ray image intensifier/television systems for digital skeletal radiography

    International Nuclear Information System (INIS)

    Rowlands, J.A.; Hynes, D.M.; Edmonds, E.W.; Porter, A.J.; Toth, B.J.

    1987-01-01

    The imaging criteria for skeletal radiography (high resolution and low noise) relevant to the use of x-ray image intensifier/TV digital systems are discussed. It is shown from the modulation transfer function (MTF), noise, and phantom evaluations that conventional x-ray image intensifiers in conjunction with a 1,000-line Plumbicon or Saticon TV camera are in most respects suitable for skeletal radiography. The optimum focal spot size depends on a trade-off with motion blurring through the x-ray exposure time and so is a function of the clinical problem. Since the skeletal system is readily immobilized, a 0.3-mm focal spot size is nearly optimum

  15. Critérios de positividade para cervicografia digital: melhorando a sensibilidade do diagnóstico do câncer cervical Digital cervicography criteria: improving sensitivity in uterine cervical cancer diagnosis

    Directory of Open Access Journals (Sweden)

    Eugênio Santana Franco

    2008-11-01

    Full Text Available O objetivo deste trabalho foi validar critérios de positividade para cervicografia digital. Estudo realizado com 300 mulheres submetidas a protocolo clínico composto por exame citológico, uma avaliação por meio de cervicografia digital sem ampliação de imagem (Avaliação 1, e outra avaliação também usando cervicografia digital mas com ampliação adicional de imagem e os critérios de positividade propostos neste estudo (Avaliação 2. A idade média das mulheres foi de 27,6 anos. Os critérios de positividade para cervicografia digital foram identificados em 111 casos (100% dos testes positivos para lesões precursoras do câncer do colo uterino e em 8 casos (2,6% considerados falso-positivos. As avaliações 1 e 2 classificaram os exames como positivos (163; 54,3% e suspeitos (146; 48,6%, respectivamente. Os resultados revelam que a cervicografia digital foi mais sensível (99,1% e a citologia mais específica (100%. O desempenho alcançado pela cervicografia digital, quando aplicado os critérios de positividade, alcançou sensibilidade 4,5 vezes superior ao desempenho da citologia oncológica, além do baixo custo, sugerindo ser uma técnica factível.This study aimed to validate the scoring criteria for digital cervicography. The study enrolled 300 women submitted to a clinical protocol using cytological examination alone, digital cervicography without image magnification (Evaluation 1, and digital cervicography plus additional image magnification and considering the positive criteria (Evaluation 2. Women's mean age was 27.6 years. Positive criteria for digital cervicography were identified in 111 positive cases with pre-cancerous cervical lesions (100% and in 8 cases classified as false positives (2.6%. Evaluations 1 and 2 classified the tests as positive (163; 54.3% and suspected (146; 48.6%, respectively. According to the findings, digital cervicography was more sensitive (99.1% and cytology more specific (100%. Digital

  16. Self-propelled pulse X-ray apparatus Sirena-1

    International Nuclear Information System (INIS)

    Danil'chenko, N.T.; Ershov, L.S.; Il'chenko, A.V.; Krasil'nikov, S.B.; Kristalinskij, A.L.; Lozovoj, L.N.; Markov, S.N.; Morgovskij, L.Ya.

    1984-01-01

    The structure and specifications of a self-propelled pulse X-ray apparatus ''Sirena-1'' for testing oilt and gas pipelines welded joints are described. The apparatus is designed on the base of pulse X-ray apparatus MIRA. Apparatus control is realized by means of the 137 Cs source or manual control desk. The apparatus ensures perfect control sensitivity

  17. Methods for reducing singly reflected rays on the Wolter-I focusing mirrors of the FOXSI rocket experiment

    Science.gov (United States)

    Buitrago-Casas, Juan Camilo; Elsner, Ronald; Glesener, Lindsay; Christe, Steven; Ramsey, Brian; Courtade, Sasha; Ishikawa, Shin-nosuke; Narukage, Noriyuki; Turin, Paul; Vievering, Juliana; Athiray, P. S.; Musset, Sophie; Krucker, Säm.

    2017-08-01

    In high energy solar astrophysics, imaging hard X-rays by direct focusing offers higher dynamic range and greater sensitivity compared to past techniques that used indirect imaging. The Focusing Optics X-ray Solar Imager (FOXSI) is a sounding rocket payload that uses seven sets of nested Wolter-I figured mirrors together with seven high-sensitivity semiconductor detectors to observe the Sun in hard X-rays through direct focusing. The FOXSI rocket has successfully flown twice and is funded to fly a third time in summer 2018. The Wolter-I geometry consists of two consecutive mirrors, one paraboloid and one hyperboloid, that reflect photons at grazing angles. Correctly focused X-rays reflect once per mirror segment. For extended sources, like the Sun, off-axis photons at certain incident angles can reflect on only one mirror and still reach the focal plane, generating a background pattern of singly reflected rays (i.e., ghost rays) that can limit the sensitivity of the observation to faint, focused sources. Understanding and mitigating the impact of the singly reflected rays on the FOXSI optical modules will maximize the instruments' sensitivity to background-limited sources. We present an analysis of the FOXSI singly reflected rays based on ray-tracing simulations and laboratory measurements, as well as the effectiveness of different physical strategies to reduce them.

  18. Detection of cosmic ray tracks using scintillating fibers and position sensitive multi-anode photomultipliers

    International Nuclear Information System (INIS)

    Atac, M.; Streets, J.; Wilcer, N.

    1998-02-01

    This experiment demonstrates detection of cosmic ray tracks by using Scintillating fiber planes and multi-anode photomultipliers (MA-PMTs). In a laboratory like this, cosmic rays provide a natural source of high-energy charged particles which can be detected with high efficiency and with nanosecond time resolution

  19. Trace rare earth analysis by neutron activation and γ-ray/x-ray spectrometry

    International Nuclear Information System (INIS)

    Laul, J.C.; Nielson, K.K.; Wogman, N.A.

    1977-01-01

    A rare earth group separation scheme followed by photon energy analysis using Ge(Li) and intrinsic Ge detectors enhances significantly the detection of individual rare earth elements (REE) at or below the ppb level. Based on the x-ray and selected γ-ray energies, Ge(Li) γ-ray counting is favorable for 140 La, 141 Ce, 142 Pr, 153 Sm, 171 Er, and 177 Lu, whereas intrinsic Ge γ-ray counting is favorable for 143 Ce, 147 Nd, 160 Tb, and 166 Ho, and intrinsic Ge x-ray counting is favorable for 152 Eu and 175 Yb. Gamma-ray counting of 153 Gd and 170 Tm is equally sensitive with Ge(Li) or intrinsic Ge detectors. Precise measurements of the REE were made in the USGS geological samples BCR-1, W-1, AGV-1, G2, GSP-1 and PCC-1, the IAEA Soil-5, and the NBS orchard leaf and bovine liver standards. Their chondritic normalized REE patterns behave as a smooth function of the REE ionic radii. Interestingly, the REE patterns observed in orchard leaf and other plants are identical to the REE pattern in bovine liver. This comparison leads us to suggest that the plant REE patterns are probably not further fractionated by animals such as bovine during their dietary plant uptake

  20. Development on mini X-ray diode

    International Nuclear Information System (INIS)

    Jiang Shaoen; Sun Kexu; Peng Nengling; Huang Tianxuan; Cui Yanli; Yi Rongqing; Chen Jiusen

    2004-01-01

    The mini X-ray diode (M-XRD) was developed, and was used in mini soft X-ray spectrometer. Compared with traditional XRD, M-XRD's volume reduces to 1/30. M-XRD's property was experimentally examined on Shenguang II laser facility. The experimental results indicated that the temporal response and sensitivity of M-XRD are basically consistent with traditional XRD. The equivalent circuit of XRD was analyzed, and its response time and linear saturated current were calculated. (authors)

  1. Radiography of X-ray in coral reefs

    International Nuclear Information System (INIS)

    Djoli Soembogo

    2016-01-01

    The application of X-ray radiography has been developed and it is already widely used in metal materials such as metal steel and carbon steel. This radiography using a source of radiation from X-ray machines. This research attempts to use the application of digital radiography X-ray source and use scanner Epson V700 positive films media for digitization results of conventional radiographic films on coral reefs. It has been testing radiography using Fuji film 100 to get the contrast medium, the sensitivity of the medium and image quality is good, Single Wall Single Image method , and using the media scanner films positive and X-ray sources, observation parameter are density radiographic film and the defect shape. Radiography uses Fuji film 100 to obtain a good contrast medium, good medium sensitivity and good quality image. Radiography of X-ray on coral reefs aims to find defects or discontinuities coral reefs such as porosity which would interfere with the determination of the age of the coral reefs. X-ray exposure time is 1 seconds for a thickness of 5.45 mm and 5.60 mm coral reefs by using a high voltage X-ray machine Rigaku of 130 kV. The result of the positive film scanner in the form of digital radiography that allows for the transfer of digital data or digital computerized data storage. The test results of radiographic on coral reefs with Single Wall Single Image method obtained radiographic film density parameter for Fuji film 100 on coral reefs No. 2 are 2.55; 2.53; 2.59 and on coral reefs No. 4 are 2.62; 2.65; 2.66, unsharpness geometric of radiographic results obtained 0.022 mm and 0.023 mm, sensitivity radiography are 1.648% and 1.604%. No defect found of Porosity that is significant. Status is acceptable for Fuji film 100, because the density of the film is in conformity with the standards referred to. Status of coral reefs No. 2 and No. 4 can be accepted, because it has conformed with the standards referred. (author)

  2. Design of a scattering polarimeter for hard X-ray astronomy

    International Nuclear Information System (INIS)

    Costa, E.; Cinti, M.N.; Feroci, M.; Matt, G.; Rapisarda, M.

    1995-01-01

    The design of a new hard X-ray Compton scattering polarimeter based on scintillating fibre technology is presented and studied in detail by means of Monte Carlo calculations. Several different configurations and materials have been tested in order to optimise the sensitivity in the medium/high energy X-ray band. A high sensitivity over the energy band 20-200 keV is obtained for a two material configuration. The advantages deriving from employing a new scintillating material, the YAP (YAlO 3 ), are also discussed. (orig.)

  3. SENSIT: a cross-section and design sensitivity and uncertainty analysis code. [In FORTRAN for CDC-7600, IBM 360

    Energy Technology Data Exchange (ETDEWEB)

    Gerstl, S.A.W.

    1980-01-01

    SENSIT computes the sensitivity and uncertainty of a calculated integral response (such as a dose rate) due to input cross sections and their uncertainties. Sensitivity profiles are computed for neutron and gamma-ray reaction cross sections of standard multigroup cross section sets and for secondary energy distributions (SEDs) of multigroup scattering matrices. In the design sensitivity mode, SENSIT computes changes in an integral response due to design changes and gives the appropriate sensitivity coefficients. Cross section uncertainty analyses are performed for three types of input data uncertainties: cross-section covariance matrices for pairs of multigroup reaction cross sections, spectral shape uncertainty parameters for secondary energy distributions (integral SED uncertainties), and covariance matrices for energy-dependent response functions. For all three types of data uncertainties SENSIT computes the resulting variance and estimated standard deviation in an integral response of interest, on the basis of generalized perturbation theory. SENSIT attempts to be more comprehensive than earlier sensitivity analysis codes, such as SWANLAKE.

  4. Stimulated X-Ray Emission Spectroscopy in Transition Metal Complexes

    Science.gov (United States)

    Kroll, Thomas; Weninger, Clemens; Alonso-Mori, Roberto; Sokaras, Dimosthenis; Zhu, Diling; Mercadier, Laurent; Majety, Vinay P.; Marinelli, Agostino; Lutman, Alberto; Guetg, Marc W.; Decker, Franz-Josef; Boutet, Sébastien; Aquila, Andy; Koglin, Jason; Koralek, Jake; DePonte, Daniel P.; Kern, Jan; Fuller, Franklin D.; Pastor, Ernest; Fransson, Thomas; Zhang, Yu; Yano, Junko; Yachandra, Vittal K.; Rohringer, Nina; Bergmann, Uwe

    2018-03-01

    We report the observation and analysis of the gain curve of amplified K α x-ray emission from solutions of Mn(II) and Mn(VII) complexes using an x-ray free electron laser to create the 1 s core-hole population inversion. We find spectra at amplification levels extending over 4 orders of magnitude until saturation. We observe bandwidths below the Mn 1 s core-hole lifetime broadening in the onset of the stimulated emission. In the exponential amplification regime the resolution corrected spectral width of ˜1.7 eV FWHM is constant over 3 orders of magnitude, pointing to the buildup of transform limited pulses of ˜1 fs duration. Driving the amplification into saturation leads to broadening and a shift of the line. Importantly, the chemical sensitivity of the stimulated x-ray emission to the Mn oxidation state is preserved at power densities of ˜1020 W /cm2 for the incoming x-ray pulses. Differences in signal sensitivity and spectral information compared to conventional (spontaneous) x-ray emission spectroscopy are discussed. Our findings build a baseline for nonlinear x-ray spectroscopy for a wide range of transition metal complexes in inorganic chemistry, catalysis, and materials science.

  5. On response operator in semiconductor gamma ray spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Krnac, S [Slovak Technical Univ., Bratislava (Slovakia); Povinec, P [International Atomic Energy Agency, Monaco (Monaco). MEL; Ragan, R [Inst. of Preventive and Clinical Medicine, Bratislava (Slovakia)

    1996-12-31

    Some results of the scaling confirmation factor analysis (SCFA) application in semiconductor gamma-ray spectrometry presented in this contribution points out to a new ground for evaluation the gamma-ray spectra. This whole-spectrum processing approach considerably increases detection sensitivity, especially, if significant interferences being present in the measured spectrum. Precision of the SCFA method is determined by choice of a sufficient number of suitable calibration gamma-ray sources in the energy region of interest, by setting up an acceptable latent hypothesis and by chosen experimental quantification of spectra. The SCFA method is very advantageous to use, for instance, in ultra low-level gamma-spectrometry where counting rates in full energy peaks are extremely low as compared with background interferences. It enables to increase of the sensitivity by the 5-10 times in comparison with the traditional full energy peak net area method (J.K.). 1 fig., 2 tabs., 6 refs.

  6. On response operator in semiconductor gamma ray spectrometry

    International Nuclear Information System (INIS)

    Krnac, S.; Povinec, P.

    1995-01-01

    Some results of the scaling confirmation factor analysis (SCFA) application in semiconductor gamma-ray spectrometry presented in this contribution points out to a new ground for evaluation the gamma-ray spectra. This whole-spectrum processing approach considerably increases detection sensitivity, especially, if significant interferences being present in the measured spectrum. Precision of the SCFA method is determined by choice of a sufficient number of suitable calibration gamma-ray sources in the energy region of interest, by setting up an acceptable latent hypothesis and by chosen experimental quantification of spectra. The SCFA method is very advantageous to use, for instance, in ultra low-level gamma-spectrometry where counting rates in full energy peaks are extremely low as compared with background interferences. It enables to increase of the sensitivity by the 5-10 times in comparison with the traditional full energy peak net area method (J.K.). 1 fig., 2 tabs., 6 refs

  7. The X-ray Telescope of the CAST Experiment

    CERN Document Server

    Kotthaus, Rainer; Friedrich, P.; Kang, D.; Hartmann, R.; Kuster, M.; Lutz, G.; Strüder, L.

    2005-01-01

    The CERN Axion Solar Telescope (CAST) searches for solar axions employing a 9 Tesla superconducting dipole magnet equipped with 3 independent detection systems for X-rays from axion-photon conversions inside the 10 m long magnetic field. Results of the first 6 months of data taking in 2003 imply a 95 % CL upper limit on the axion-photon coupling constant of 1.16x10(-10) GeV(-1) for axion masses < 0.02 eV. The most sensitive detector of CAST is a X-ray telescope consisting of a Wolter I type mirror system and a fully depleted pn-CCD as focal plane detector. Exploiting the full potential of background suppression by focussing X-rays emerging from the magnet bore, the axion sensitivity obtained with telescope data taken in 2004, for the first time in a controlled laboratory experiment, will supersede axion constraints derived from stellar energy loss arguments.

  8. Classification of X-ray sources in the direction of M31

    Science.gov (United States)

    Vasilopoulos, G.; Hatzidimitriou, D.; Pietsch, W.

    2012-01-01

    M31 is our nearest spiral galaxy, at a distance of 780 kpc. Identification of X-ray sources in nearby galaxies is important for interpreting the properties of more distant ones, mainly because we can classify nearby sources using both X-ray and optical data, while more distant ones via X-rays alone. The XMM-Newton Large Project for M31 has produced an abundant sample of about 1900 X-ray sources in the direction of M31. Most of them remain elusive, giving us little signs of their origin. Our goal is to classify these sources using criteria based on properties of already identified ones. In particular we construct candidate lists of high mass X-ray binaries, low mass X-ray binaries, X-ray binaries correlated with globular clusters and AGN based on their X-ray emission and the properties of their optical counterparts, if any. Our main methodology consists of identifying particular loci of X-ray sources on X-ray hardness ratio diagrams and the color magnitude diagrams of their optical counterparts. Finally, we examined the X-ray luminosity function of the X-ray binaries populations.

  9. Combining the IADPSG criteria with the WHO diagnostic criteria for ...

    African Journals Online (AJOL)

    Macrosomia or at least one adverse outcome were more likely in GDM patients who met the diagnostic criteria by both the IADPSG and WHO criteria (P = 0.001). Conclusion: A diagnosis of GDM that meets both the WHO and IADPSG criteria provides stronger prediction for adverse pregnancy outcome than a diagnosis that ...

  10. High-resolution accelerator alignment using x-ray optics

    Directory of Open Access Journals (Sweden)

    Bingxin Yang

    2006-03-01

    Full Text Available We propose a novel alignment technique utilizing the x-ray beam of an undulator in conjunction with pinholes and position-sensitive detectors for positioning components of the accelerator, undulator, and beam line in an x-ray free-electron laser. Two retractable pinholes at each end of the undulator define a stable and reproducible x-ray beam axis (XBA. Targets are precisely positioned on the XBA using a pinhole camera technique. Position-sensitive detectors responding to both x-ray and electron beams enable direct transfer of the position setting from the XBA to the electron beam. This system has the potential to deliver superior alignment accuracy (1–3   μm for target pinholes in the transverse directions over a long distance (200 m or longer. It can be used to define the beam axis of the electron-beam–based alignment, enabling high reproducibility of the latter. This x-ray–based concept should complement the electron-beam–based alignment and the existing survey methods to raise the alignment accuracy of long accelerators to an unprecedented level. Further improvement of the transverse accuracy using x-ray zone plates will be discussed. We also propose a concurrent measurement scheme during accelerator operation to allow real-time feedback for transverse position correction.

  11. Recording soft-X-ray images with photographic materials at large gamma background

    International Nuclear Information System (INIS)

    Izrailev, I.M.

    1993-01-01

    The sensitivity of photographic materials to soft X-rays and 60 Co γ-quanta when developed by visible light and a chemical developer is investigated. When the photographic paper is developed by visible light, its sensitivity is reduced by 200-300 times independent of the quantum energy. This method allows an X-ray image to be recorded even when there is γ-background of 10 5 R. 2 refs., 1 tab

  12. High-speed image converter x-ray studies

    International Nuclear Information System (INIS)

    Bryukhnevitch, G.I.; Kas'yanov, Yu.S.; Korobkin, V.V.; Prokhorov, A.M.; Stepanov, B.M.; Chevokin, V.K.; Schelev, M.Ya.

    1975-01-01

    Two X-ray high-speed image-converter cameras (ICC) have been developed. In the first one a soft X-ray radiation is converted into visible light with the aid of a 0.5ns response time, plastic scintillator. The second camera incorporates a photocathode which is sensitive to visible and X-ray radiation. Its calculated temporal resolution approaches 5 to 7ps. Both developed cameras were employed for studies of X-ray radiation emitted by laser plasma. For the smooth nanosecond excited laser pulses, a noticeable amplitude modulation was recorded in all laser pulses reflected by plasma as well as in each third pulse of X-ray plasma radiation. It was also observed that the duration of X-ray plasma radiation is 20 to 40% shorter than that of the incident nanosecond laser pulses and this duration being 3 to 6 times longer than that of the picosecond irradiating pulses. The half-width of the recorded X-ray plasma pulses was 30 to 60ps. (author)

  13. X-ray phase-contrast imaging

    Science.gov (United States)

    Endrizzi, Marco

    2018-01-01

    X-ray imaging is a standard tool for the non-destructive inspection of the internal structure of samples. It finds application in a vast diversity of fields: medicine, biology, many engineering disciplines, palaeontology and earth sciences are just few examples. The fundamental principle underpinning the image formation have remained the same for over a century: the X-rays traversing the sample are subjected to different amount of absorption in different parts of the sample. By means of phase-sensitive techniques it is possible to generate contrast also in relation to the phase shifts imparted by the sample and to extend the capabilities of X-ray imaging to those details that lack enough absorption contrast to be visualised in conventional radiography. A general overview of X-ray phase contrast imaging techniques is presented in this review, along with more recent advances in this fast evolving field and some examples of applications.

  14. Detection Techniques of Microsecond Gamma-Ray Bursts Using Ground-based Telescopes

    International Nuclear Information System (INIS)

    Krennrich, F.; Le Bohec, S.; Weekes, T. C.

    2000-01-01

    Gamma-ray observations above 200 MeV are conventionally made by satellite-based detectors. The EGRET detector on the Compton Gamma Ray Observatory has provided good sensitivity for the detection of bursts lasting for more than 200 ms. Theoretical predictions of high-energy gamma-ray bursts produced by quantum mechanical decay of primordial black holes (Hawking) suggest the emission of bursts on shorter timescales. The final stage of a primordial black hole results in a burst of gamma rays, peaking around 250 MeV and lasting for 1/10 of a microsecond or longer depending on particle physics. In this work we show that there is an observational window using ground-based imaging Cerenkov detectors to measure gamma-ray burst emission at energies E>200 MeV. This technique, with a sensitivity for bursts lasting nanoseconds to several microseconds, is based on the detection of multiphoton-initiated air showers. (c) (c) 2000. The American Astronomical Society

  15. Technology Needs for Gamma Ray Astronomy

    Science.gov (United States)

    Gehrels, Neil

    2011-01-01

    Gamma ray astronomy is currently in an exciting period of multiple missions and a wealth of data. Results from INTEGRAL, Fermi, AGILE, Suzaku and Swift are making large contributions to our knowledge of high energy processes in the universe. The advances are due to new detector and imaging technologies. The steps to date have been from scintillators to solid state detectors for sensors and from light buckets to coded aperture masks and pair telescopes for imagers. A key direction for the future is toward focusing telescopes pushing into the hard X-ray regime and Compton telescopes and pair telescopes with fine spatial resolution for medium and high energy gamma rays. These technologies will provide finer imaging of gamma-ray sources. Importantly, they will also enable large steps forward in sensitivity by reducing background.

  16. Comparison of diagnostic classification systems for delirium with new research criteria that incorporate the three core domains.

    Science.gov (United States)

    Trzepacz, Paula T; Meagher, David J; Franco, José G

    2016-05-01

    Diagnostic classification systems do not incorporate phenomenological research findings about the three core symptom domains of delirium (Attentional/Cognitive, Circadian, Higher Level Thinking). We evaluated classification performances of novel Trzepacz, Meagher, and Franco research diagnostic criteria (TMF) that incorporate those domains and ICD-10, DSM-III-R, DSM-IV, and DSM-5. Primary data analysis of 641 patients with mixed neuropsychiatric profiles. Delirium (n=429) and nondelirium (n=212) reference standard groups were identified using cluster analysis of symptoms assessed using the Delirium Rating Scale-Revised-98. Accuracy, sensitivity, specificity, positive and negative predictive values (PPV, NPV), and likelihood ratios (LR+, LR-) are reported. TMF criteria had high sensitivity and specificity (87.4% and 89.2%), more balanced than DSM-III-R (100% and 31.6%), DSM-IV (97.7% and 74.1%), DSM-5 (97.7% and 72.6%), and ICD-10 (66.2% and 100%). PPV of DSM-III-R, DSM-IV, and DSM-5 were 90%. ICD-10 had the lowest NPV (59.4%). TMF had the highest LR+ (8.06) and DSM-III-R the lowest LR- (0.0). Overall, values for DSM-IV and DSM-5 were similar, whereas for ICD-10 and DSM-III-R were inverse of each other. In the pre-existing cognitive impairment/dementia subsample (n=128), TMF retained its highest LR+ though specificity (58.3%) became less well balanced with sensitivity (87.9%), which still exceeded that of DSM. TMF research diagnostic criteria performed well, with more balanced sensitivity and specificity and the highest likelihood ratio for delirium identification. Reflecting the three core domains of delirium, TMF criteria may have advantages in biological research where delineation of this syndrome is important. Copyright © 2016. Published by Elsevier Inc.

  17. Gamma ray camera

    International Nuclear Information System (INIS)

    Wang, S.-H.; Robbins, C.D.

    1979-01-01

    An Anger gamma ray camera is improved by the substitution of a gamma ray sensitive, proximity type image intensifier tube for the scintillator screen in the Anger camera. The image intensifier tube has a negatively charged flat scintillator screen, a flat photocathode layer, and a grounded, flat output phosphor display screen, all of which have the same dimension to maintain unit image magnification; all components are contained within a grounded metallic tube, with a metallic, inwardly curved input window between the scintillator screen and a collimator. The display screen can be viewed by an array of photomultipliers or solid state detectors. There are two photocathodes and two phosphor screens to give a two stage intensification, the two stages being optically coupled by a light guide. (author)

  18. Application of synchrotron radiation to X-ray interferometry

    Energy Technology Data Exchange (ETDEWEB)

    Hart, M [King' s Coll., London (UK). Wheatstone Physics Lab.

    1980-05-01

    X-ray interferometry has been attempted with synchrotron radiation at Hamburg and at Orsay. Experiments will start this year at the Storage Ring Source at Daresbury. This review covers work which has already been completed and outlines the likely trends in phase sensitive X-ray polarimetry, high resolution spectroscopy (including real and imaginary-part EXAFS) and novel experiments with many-beam-case interferometers.

  19. Water equivalence of NIPAM based polymer gel dosimeters with enhanced sensitivity for x-ray CT

    International Nuclear Information System (INIS)

    Gorjiara, Tina; Hill, Robin; Bosi, Stephen; Kuncic, Zdenka; Baldock, Clive

    2013-01-01

    Two new formulations of N-isopropylacrylamide (NIPAM) based three dimensional (3D) gel dosimeters have recently been developed with improved sensitivity to x-ray CT readout, one without any co-solvent and the other one with isopropanol co-solvent. The water equivalence of the NIPAM gel dosimeters was investigated using different methods to calculate their radiological properties including: density, electron density, number of electrons per grams, effective atomic number, photon interaction probabilities, mass attenuation and energy absorption coefficients, electron collisional, radiative and total mass stopping powers and electron mass scattering power. Monte Carlo modelling was also used to compare the dose response of these gel dosimeters with water for kilovoltage and megavoltage x-ray beams and for megavoltage electron beams. We found that the density and electron density of the co-solvent free gel dosimeter are more water equivalent with less than a 2.6% difference compared to a 5.7% difference for the isopropanol gel dosimeter. Both the co-solvent free and isopropanol solvent gel dosimeters have lower effective atomic numbers than water, differing by 2.2% and 6.5%, respectively. As a result, their photoelectric absorption interaction probabilities are up to 6% and 19% different from water, respectively. Compton scattering and pair production interaction probabilities of NIPAM gel with isopropanol differ by up to 10% from water while for the co-solvent free gel, the differences are 3%. Mass attenuation and energy absorption coefficients of the co-solvent free gel dosimeter and the isopropanol gel dosimeter are up to 7% and 19% lower than water, respectively. Collisional and total mass stopping powers of both gel dosimeters differ by less than 2% from those of water. The dose response of the co-solvent free gel dosimeter is water equivalent (with 100 keV, correction factor is required for the gels. • For MV electron, correction factor needed for the gels to

  20. Limitations of retarded (bisulfite) x-ray film processing

    International Nuclear Information System (INIS)

    Stoering, J.P.; Dittmore, C.

    1979-01-01

    We demonstrate the limitations of using retarded (bisulfite) developer to abate film sensitivity of x-ray films that have been exposed to intense radiation. We compared the measured densities of a large number of Kodak Type-M x-ray film samples exposed to a known fluence of monochromatic x-rays. These film samples were processed in three separate batches of bisulfite developer mixed in the same proportions. We concluded that reproducible film-density information cannot be obtained using different batches of (bisulfite) developer solutions