WorldWideScience

Sample records for rapid nft systems

  1. Nutrient Film Technique (NFT Hydroponic Monitoring System

    Directory of Open Access Journals (Sweden)

    Helmy Helmy

    2016-10-01

    Full Text Available Plant cultivation using hydroponic is very popular today. Nutrient Film Technique (NFT hydroponic system is commonly used by people. It can be applied indoor or outdoor. Plants in this systemneed nutrient solution to grow well. pH, TDS and temperature of the nutrient solution must be check to ensure plant gets sufficient nutrients. This research aims todevelop monitoring system of NFT hydroponic. Farmer will be able to monitor pH, TDS and temperature online. It will ease farmer to decide which plant is suitable to be cultivated and time to boost growth.Delay of the system will be measured to know system performance. Result shows that pH is directly proportional with TDS. Temperature value has no correlation with pH and TDS. System has highest delay during daylight and afternoon but it will decline in the night and morning. Average of delay in the morning is 11 s, 28.5 s in daylight, 32 s in the afternoon and 17.5 s in the night.

  2. Production of calla lily grown in an NFT system

    Directory of Open Access Journals (Sweden)

    Paulo Roberto Correa Landgraf

    2017-12-01

    Full Text Available The objective of this study was to evaluate the production of calla lily in an NFT system. The experiment was carried out in a greenhouse, using a 2 x 2 factorial scheme in a completely randomized design (CRD, with fifteen replications. The treatments were a combination of two hydroponic profiles (100 and 150 mm of height and two nutrient solutions. Calla lily plantlets obtained from rhizome buds in trays containing nutrient solution, were transferred to a laminar flow of nutrients, and the experiment lasted 12 months. The height of stems and inflorescences were evaluated, as well as the length and diameter of the inflorescence, the number of flowers per plant and number of flowers per m2 . Growing calla lily plants in an NFT system is feasible. The nutrient solution with the highest concentration of nutrients, particularly N and K, and the profile of 150 mm, are the most suitable for the production of calla lily as a cut flower in a laminar flow of nutrients.

  3. Concentração e conteúdo de nutrientes em lisianto, cultivado em hidroponia, em sistema NFT = Concentration and nutrient content in lisianthus grown in a hydroponic NFT system

    Directory of Open Access Journals (Sweden)

    Fernanda Alice Antonello Londero Backes

    2008-10-01

    Full Text Available O diagnóstico nutricional é fundamental para determinar as exigências das plantas quanto aos nutrientes, de forma a se proceder a um manejo adequado, de acordo com a espécie. Assim, para determinar as concentrações e conteúdos nutricionais adequados à produção e qualidade de plantas de lisianto em cultivo hidropônico, instalou-se um experimento onde as plantas foram cultivadas em sistema NFT, em diferentes soluções nutritivas. O experimento foi conduzido, segundo delineamento experimental em blocos casualizados, em esquema fatorial 4x3, totalizando 12 tratamentos, com três repetições. Ostratamentos foram compostos de quatro cultivares (Echo Champagne, Mariachi Pure White, Balboa Yellow e Ávila Blue Rim e três soluções nutritivas (Teste, Steiner modificada e Barbosa. Foram avaliadas as concentrações e os conteúdos dos nutrientes nas folhas e conteúdos na parte aérea das plantas. As plantas cultivadas nas soluções Barbosa eTeste apresentaram resultados satisfatórios quanto às concentrações e aos conteúdos de nutrientes, enquanto a solução Steiner modificada produziu plantas com limitações nutricionais.The nutritional diagnosis is fundamental for determining plantnutrients, in order to correctly manage the nutritional requirements for each species. Thus, in order to determine the ideal nutrient amount and concentration for obtaining the best yield and quality of lisianthus grown hydroponically, an experiment was conducted inwhich the plants were grown under the NFT system in different nutrient solutions. The experiment was conducted according to a random block design arrangement in a 4x3 factorial scheme, totaling 12 treatments with three repetitions. The treatments werecomprised of four cultivars (Echo Champagne, Mariachi Pure White, Balboa Yellow and Ávila Blue Rim and three nutrient solutions (Test, modified Steiner and Barbosa. In the leaves, nutrient concentration and content were evaluated; in the aerial

  4. Produção de girassol ornamental com uso de águas salobras em sistema hidropônico NFT Production of ornamental sunflower with use of brackish waters in NFT hydroponic system

    Directory of Open Access Journals (Sweden)

    Marlo P Maciel

    2012-02-01

    treatment was replicated four times and each experimental unit had four plants in an independent NFT (nutrient film technique hydroponic system. A linear reduction was observed with increasing water salinity on plant height, stem diameter and fresh and dry matter of plant shoot. Both plant height and stem diameter were decreased by 3.2%, shoot dry matter was decreased 5.78% with per unit increase of water salinity (dS m-1. On the other hand, water salinity did not affect sunflower capitulum size. Systematic toxicity symptoms caused by salinity were not registered. These findings support the technical feasibility for hydroponic ornamental sunflower production using brackish waters.

  5. Inspection of NFT-type cask fabrication

    International Nuclear Information System (INIS)

    Takani, M.; Umegaki, O.

    1998-01-01

    NFT-type cask has been developed to transport the high burn-up spent fuel from Japanese nuclear power stations to the reprocessing plant of Japan Nuclear Fuel Limited which is under construction in Rokkasho-mura, Aomori prefecture. NFT placed orders of 53 casks to 5 fabricators in Japan and overseas, and these casks have been fabricated since 1994. There are two types of NFT-type casks for PWR spent fuel and four types of NFT-type cask for BWR spent fuel. These are designed in consideration of the number of spent fuels accommodated into each type of casks and the handling conditions at domestic nuclear power stations. According to Japanese notification, it is required to be confirmed by competent authority that casks are manufactured in accordance with approved designs. Furthermore, additional tests are performed such as through-gauge test for basket and pressure test on the shielding material space to ensure the performance of cask by NFT other than items inspected by the competent authority. In order to enhance maintainability of casks, replacement parts such as bolts and valves are shared as much as possible. (authors)

  6. Uso do rejeito da dessalinização de água salobra no cultivo da alface (Lactuca sativa L. em sistema hidropônico NFT Use of the desalted wastewater for lettuce (Lactuca sativa L. production in NFT hydroponic system

    Directory of Open Access Journals (Sweden)

    Rafaelly Suzanye da Silva Santos

    2010-08-01

    wastewater with high salinity. To evaluate the effect of the use of desalted water on lettuce (Lactuca sativa L. production cv. Vera in a NFT hydroponics system an experiment was carried out in a greenhouse located at the Departament of Environmental Sciences of the Universidade Federal Rural do Semi-Árido, in a statistical test with completely randomized blocks with four repetitions and six treatments. The salinity level of the war between treatments was checked with and without dilution of the wastewater, adding the nutrient solution with salinity of 1 dS m-1 (100% public water supply - 1.4 dS m-1; 85% water supply and 15% wastewater - 1.9 dS m-1; 75 % wastewater + 25 % water supply - 2.7 dS m-1; 50% wastewater e 50% water supply - 3.8 dS m-1; 25 % wastewater and 75 % water supply - 4.9 dS m-1 and wastewater gathered from desalter - 5.5 dS m-1. The number of leaves, diameter of the stem, fresh and matter biomass and leaf area were analyzed. All the analyzed variables were negatively influenced in a linear way by the effect of the concentration of salts in irrigation water. Biomass and leaf area are more sensitive to saline stress in the cultivar studied, and fresh matter production was reduced by 94.83%, when CEa was increased from 1.4 to 5.5 dS m-1.

  7. Desempenho de cultivares de alface crespa em dois ambientes de cultivo em sistema hidropônico Performance of lettuce cultivars grown in two environments, in the NFT hydroponic system

    Directory of Open Access Journals (Sweden)

    SF Blat

    2011-03-01

    Full Text Available Este trabalho foi desenvolvido em Ribeirão Preto-SP, de 06/02 a 07/04 de 2006. O objetivo foi avaliar o desempenho de cinco cultivares de alface (Pira Roxa, Belíssima, Locarno, Crespona Gigante e Verônica em dois ambientes de cultivo (casa de vegetação climatizada e não climatizada em sistema hidropônico NFT. O delineamento experimental foi em blocos casualizados para cada ambiente com três repetições sendo cinco cultivares. Os ambientes foram comparados por meio de análise conjunta. Avaliaram-se a massa fresca e seca da parte aérea, massas fresca e seca do caule, massa fresca e seca da raiz, número de folhas maiores que 10 cm e número total de folhas. Não houve efeito significativo da interação cultivares e ambientes, demonstrando que as cultivares tiveram comportamento similar em ambos os ambientes.This research was carried out in Ribeirão Preto, São Paulo State, Brazil, from February to April, 2006. The performance of five lettuce cultivars (Pira Roxa, Belíssima, Locarno, Crespona Gigante and Verônica was evaluated, growing the plants in two environments (conventional and acclimatized greenhouse in hydroponic system NFT. A randomized-block experimental design was used for each environment, with three replications and five cultivars. The environments were compared through joint analysis. Evaluations were done for fresh and dry mater of the aboveground part, stem, and roots; number of leaves larger than 10 cm and total number of leaves. The cultivars Crespona Gigante and Verônica were prominent with regard to green and dry mass of the aboveground part, leaves, and roots, as well as to the number of leaves larger than 10 cm. The interaction cultivar x environment was not significant, demonstrating that the cultivars had similar behavior in both environments.

  8. Rapid response systems.

    Science.gov (United States)

    Lyons, Patrick G; Edelson, Dana P; Churpek, Matthew M

    2018-07-01

    Rapid response systems are commonly employed by hospitals to identify and respond to deteriorating patients outside of the intensive care unit. Controversy exists about the benefits of rapid response systems. We aimed to review the current state of the rapid response literature, including evolving aspects of afferent (risk detection) and efferent (intervention) arms, outcome measurement, process improvement, and implementation. Articles written in English and published in PubMed. Rapid response systems are heterogeneous, with important differences among afferent and efferent arms. Clinically meaningful outcomes may include unexpected mortality, in-hospital cardiac arrest, length of stay, cost, and processes of care at end of life. Both positive and negative interventional studies have been published, although the two largest randomized trials involving rapid response systems - the Medical Early Response and Intervention Trial (MERIT) and the Effect of a Pediatric Early Warning System on All-Cause Mortality in Hospitalized Pediatric Patients (EPOCH) trial - did not find a mortality benefit with these systems, albeit with important limitations. Advances in monitoring technologies, risk assessment strategies, and behavioral ergonomics may offer opportunities for improvement. Rapid responses may improve some meaningful outcomes, although these findings remain controversial. These systems may also improve care for patients at the end of life. Rapid response systems are expected to continue evolving with novel developments in monitoring technologies, risk prediction informatics, and work in human factors. Copyright © 2018 Elsevier B.V. All rights reserved.

  9. Tolerance of continuous NFT spectrum to the optical fiber channel impairments

    DEFF Research Database (Denmark)

    Gaiarin, Simone; Da Ros, Francesco; Sørensen, Mads Peter

    2016-01-01

    The impact of launch power, additive white Gaussian noise and fiber loss on the nonlinear Fourier transform (NFT) continuous spectrum is investigated. NFT is shown to undergo lower spectral distortion than the discrete Fourier transform.......The impact of launch power, additive white Gaussian noise and fiber loss on the nonlinear Fourier transform (NFT) continuous spectrum is investigated. NFT is shown to undergo lower spectral distortion than the discrete Fourier transform....

  10. The non-flagellar type III secretion system evolved from the bacterial flagellum and diversified into host-cell adapted systems.

    Directory of Open Access Journals (Sweden)

    Sophie S Abby

    2012-09-01

    Full Text Available Type 3 secretion systems (T3SSs are essential components of two complex bacterial machineries: the flagellum, which drives cell motility, and the non-flagellar T3SS (NF-T3SS, which delivers effectors into eukaryotic cells. Yet the origin, specialization, and diversification of these machineries remained unclear. We developed computational tools to identify homologous components of the two systems and to discriminate between them. Our analysis of >1,000 genomes identified 921 T3SSs, including 222 NF-T3SSs. Phylogenomic and comparative analyses of these systems argue that the NF-T3SS arose from an exaptation of the flagellum, i.e. the recruitment of part of the flagellum structure for the evolution of the new protein delivery function. This reconstructed chronology of the exaptation process proceeded in at least two steps. An intermediate ancestral form of NF-T3SS, whose descendants still exist in Myxococcales, lacked elements that are essential for motility and included a subset of NF-T3SS features. We argue that this ancestral version was involved in protein translocation. A second major step in the evolution of NF-T3SSs occurred via recruitment of secretins to the NF-T3SS, an event that occurred at least three times from different systems. In rhizobiales, a partial homologous gene replacement of the secretin resulted in two genes of complementary function. Acquisition of a secretin was followed by the rapid adaptation of the resulting NF-T3SSs to multiple, distinct eukaryotic cell envelopes where they became key in parasitic and mutualistic associations between prokaryotes and eukaryotes. Our work elucidates major steps of the evolutionary scenario leading to extant NF-T3SSs. It demonstrates how molecular evolution can convert one complex molecular machine into a second, equally complex machine by successive deletions, innovations, and recruitment from other molecular systems.

  11. Implementasi Fuzzy Logic Controller untuk Mengatur Ph Nutrisi pada Sistem Hidroponik Nutrient Film Technique (NFT

    Directory of Open Access Journals (Sweden)

    Dian Pancawati

    2016-07-01

    Full Text Available One solution to solve limited agricultural land is applying hydroponics Nutrient Film Technique (NFT. The advantage of NFT is using water circulated as a growing medium in order to obtain water, nutrients and oxygen to accelerate the growth of plants with good results. The most important parameter is the pH of nutrients. This article discusses how to design an automatic nutritional pH control system by implementing the method of Fuzzy Logic Controller. The control system use Arduino Mega2560, Analog pH Meter Kit as input, and the solenoid valve as actuators. The best response of the implementation of Fuzzy Logic Controller with the system which has 25 rules. The response shows that the system has in 1200 millisecond rise time and the steady state in 5530 milliseconds to increase the pH. While to decrease the pH system has response of rise time at 2000 milliseconds and steady state at the time of 3000 milliseconds. The system is able to maintain the pH at 5.5, with the result of the growth of lettuce as high as 20 cm and seven leaves for 54 days.

  12. PENERAPAN PANJANG TALANG DAN JARAK TANAM DENGAN SISTEM HIDROPONIK NFT (Nutrient Film Technique PADA TANAMAN KAILAN (Brassica oleraceae var. alboglabra

    Directory of Open Access Journals (Sweden)

    Daviv Zali Vidianto

    2013-09-01

    Full Text Available Kailan vegetables is one kind of high economic value that can be grown in hydroponic NFT (Nutrient Film Technique. The purpose of this study to determine the effect of chamfer length and spacing of the system hydroponic NFT (Nutrient Film Technique on the growth and yield kailan (Brassica oleraceae var. Alboglabra. The research has been done in the greenhouse of the Faculty of Agriculture, University Department Agroekoteknologi Trunojoyo Madura District Kamal village Telang Bangkalan. Tat is was conducted in February-May 2012. Research using methods completely randomized design (CRD with non factorial treatment chamfer length 2 m with spacing of 15 cm (P1J1, chamfer length 2 m with spacing of 20 cm (P1J2, chamfer length of 4 m with spacing of 15 cm (P2J1 and chamfer length of 4 m with spacing of 20 cm (P2J2. The materials used are kailan seeds, fertilizers and hydroponics Goodplant acetic acid (CH3COOH. Observations were analyzed using analysis of variance and Duncan continued Test Distance (UJD level of 5%. P1J1 (chamfer length of 2 meters and 15 cm plant spacing gives the best effect on the variable root length, number of leaves and plant canopy wet weight. The treatment does’n effect to variable leaf area, root wet weight, dry weight, and root dry weight of the plant canopyKeyword : Brassica oleraceae var. Alboglabra, hydroponik NFT, chamfer length and spacing

  13. Rapid inventory taking system

    International Nuclear Information System (INIS)

    Marsden, P.S.S.F.

    1980-01-01

    A data processing system designed to facilitate inventory taking is described. The process depends upon the earliest possible application of computer techniques and the elimination of manual operations. Data is recorded in optical character recognition (OCR) 'A' form and read by a hand held wand reader. Limited validation checks are applied before recording on mini-tape cassettes. 5 refs

  14. Rapid deployment intrusion detection system

    International Nuclear Information System (INIS)

    Graham, R.H.

    1997-01-01

    A rapidly deployable security system is one that provides intrusion detection, assessment, communications, and annunciation capabilities; is easy to install and configure; can be rapidly deployed, and is reusable. A rapidly deployable intrusion detection system (RADIDS) has many potential applications within the DOE Complex: back-up protection for failed zones in a perimeter intrusion detection and assessment system, intrusion detection and assessment capabilities in temporary locations, protection of assets during Complex reconfiguration, and protection in hazardous locations, protection of assets during Complex reconfiguration, and protection in hazardous locations. Many DOE user-need documents have indicated an interest in a rapidly deployable intrusion detection system. The purpose of the RADIDS project is to design, develop, and implement such a system. 2 figs

  15. Rapidly Degradable Pyrotechnic System

    Science.gov (United States)

    2009-02-01

    material system (structural polymer and degradation agent ) for producing a high strength, non-corroding, highly inert, environmentally safe, extended...polymer sites in the active enzyme center differs dramatically between alkyl and aromatic polyesters. More specifically, as the degree of backbone...capped and centrifuged at 3,000 g. This procedure was repeated twice. To the remaining biomass pellet 15 mL of 1 mg/mL solution of N-ethyl-N- nitrosourea

  16. Extension of Aquaponic Water Use for NFT Baby-Leaf Production: Mizuna and Rocket Salad

    Directory of Open Access Journals (Sweden)

    Carlo Nicoletto

    2018-05-01

    Full Text Available Aquaponics is a recirculating technology that combines aquaculture with hydroponics. It allows nutrients from fish waste to feed plants and thus saves water and nutrients. However, there is a mismatch between the nutrients provided by the fish waste and plant needs. Because of this, some nutrients, notably N, tend to accumulate in the aquaponic water (APW or AP water. The aim of this study was to investigate how APW, which is depleted of P and K but still rich in N, could be further utilized. APW was used in a mesocosm and compared with APW from the same source that had been supplemented with macro-nutrients (complemented AP water or CAPW and a hydroponic control (HC. Mizuna (M and rocket salad (R were used as short-cycle vegetable crops in a NFT system. The results revealed that the low production potential of APW was mainly caused by the lack of P and K. If these were supplemented, the yields were comparable to those in the HC. M yield in CAPW was significantly higher than that of HC, probably due to biostimulant effects connected to the organic components in the water as a result of fish farming. Water type, cultivation density, and intercropping significantly influenced the qualitative characteristics of the crop in terms of antioxidant compounds and minerals. Nitrate content in vegetables was lower than European regulation limits. The extended use of APW is viable if the missing nutrients are supplemented; this could be a strategy to increase the efficiency of water and nitrogen use, while further reducing environmental impact.

  17. Rapid Automated Mission Planning System, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — The proposed innovation is an automated UAS mission planning system that will rapidly identify emergency (contingency) landing sites, manage contingency routing, and...

  18. The renormalization of collective states and the improper initial or final states in NFT

    International Nuclear Information System (INIS)

    Bes, D.R.; Dussel, G.G.; Perazzo, R.P.J.; Sofia, H.M.

    1978-01-01

    The collective lines in a given diagram are renormalized by including higher order processes. The problem is cast into the form of a conventional linear algebraic matrix equation that allows a simple treatment of the normalization conditions. It is shown that the states entering in the renormalization of the phonons become improper initial or final states, if dressed phonons are used in the intermediate states. A simple extension of this argument allows one to justify one of the rules given in the formulation of the NFT. (Auth.)

  19. A Systems Approach to Rapid School Improvement

    Science.gov (United States)

    McCauley, Carlas

    2018-01-01

    To support systemic thinking about school improvement, the Center on School Turnaround at WestEd developed a framework to assist states, districts, and schools in leading and managing rapid improvement efforts. The framework, which is presented in this article, has four domains that have proved central to rapid, significant improvement: (1)…

  20. Enhancing creative cognition with a rapid right-parietal neurofeedback procedure.

    Science.gov (United States)

    Agnoli, Sergio; Zanon, Marco; Mastria, Serena; Avenanti, Alessio; Corazza, Giovanni Emanuele

    2018-02-14

    The present article describes an innovative neurofeedback training (NFT) procedure aimed at increasing creative cognition through the enhancement of specific brain activities previously associated with divergent thinking. We designed and tested two NFT protocols based on training alpha and beta EEG oscillations selectively measured over the right parietal region. A total of 80 participants were involved, 40 in the alpha NFT protocol and 40 in the beta NFT protocol. The NFT loop was closed on a video stream that would advance only when oscillation power exceeded a normalized threshold. The total duration of the protocol was two hours in a single day, hence its classification as rapid. Changes in ideational fluency and originality, measured with a divergent thinking task, were compared between participants receiving real video feedback and participants receiving sham feedback. We controlled for individual differences in creative achievement level. Results showed that the protocols were effective at enhancing alpha and beta activities in the targeted area. Differences between the two protocols emerged in their effectiveness at promoting divergent thinking. While no significant changes in originality resulted from the rapid alpha NFT, increases in both originality and fluency emerged as a consequence of the rapid beta NFT. These results were particularly evident in participants starting with a low creative achievement level. Possible interpretations and future directions are proposed and discussed. Copyright © 2018 Elsevier Ltd. All rights reserved.

  1. EEGLAB, SIFT, NFT, BCILAB, and ERICA: new tools for advanced EEG processing.

    Science.gov (United States)

    Delorme, Arnaud; Mullen, Tim; Kothe, Christian; Akalin Acar, Zeynep; Bigdely-Shamlo, Nima; Vankov, Andrey; Makeig, Scott

    2011-01-01

    We describe a set of complementary EEG data collection and processing tools recently developed at the Swartz Center for Computational Neuroscience (SCCN) that connect to and extend the EEGLAB software environment, a freely available and readily extensible processing environment running under Matlab. The new tools include (1) a new and flexible EEGLAB STUDY design facility for framing and performing statistical analyses on data from multiple subjects; (2) a neuroelectromagnetic forward head modeling toolbox (NFT) for building realistic electrical head models from available data; (3) a source information flow toolbox (SIFT) for modeling ongoing or event-related effective connectivity between cortical areas; (4) a BCILAB toolbox for building online brain-computer interface (BCI) models from available data, and (5) an experimental real-time interactive control and analysis (ERICA) environment for real-time production and coordination of interactive, multimodal experiments.

  2. Classroom Evaluation of a Rapid Prototyping System.

    Science.gov (United States)

    Tennyson, Stephen A.; Krueger, Thomas J.

    2001-01-01

    Introduces rapid prototyping which creates virtual models through a variety of automated material additive processes. Relates experiences using JP System 5 in freshman and sophomore engineering design graphics courses. Analyzes strengths and limitations of the JP System 5 and discusses how to use it effectively. (Contains 15 references.)…

  3. Produção de alface em NFT e Floating aproveitando água salobra e o rejeito da dessalinização Lettuce production under NFT and Floating using brackish groundwater and the reject from its desalination

    Directory of Open Access Journals (Sweden)

    Alexandre Nascimento dos Santos

    2011-06-01

    Full Text Available Plantas de alface cv. Elba foram cultivadas em dois sistemas hidropônicos, Floating e NFT, com o objetivo de avaliar três tipos de água: a água salobra natural (2,47 dS m-1 obtida a partir de um poço profundo; água doce (0,11 dS m-1 produzido por dessalinização por osmose inversa, e o rejeito salino (5,15 dS m-1, um efluente do processo de dessalinização. Estas águas foram combinadas em seis tratamentos resultantes da sua utilização alternada para preparar a solução nutritiva (SN e/ou substituir as perdas por evapotranspiração (ETc. O experimento foi conduzido em casa de vegetação na região semiárida de Pernambuco, utilizando 48 unidades experimentais em blocos casualizados em esquema fatorial 6x2 com quatro repetições. O rendimento da alface (massa de matéria fresca foi maior nas condições do Floating. O uso exclusivo da água do poço profundo e do rejeito de dessalinizadores diminuiu 22,7 e 39,6% a produção de alface, respectivamente. Para uma melhor combinação de águas doces e salobras, o uso de água salobra para repor a perda por ETc pode aumentar a produção de alface em relação ao uso dessas águas para preparar a SN, estes resultados foram registrados para a água do poço profundo e o rejeito.Plants of lettuce cv. Elba were grown under two hydroponic systems, Floating and NFT, aiming to evaluate three water resources: natural brackish water (2,47 dS m-1 obtained from a deep well; fresh water (0,11 dS m-1 produced by reverse osmosis desalination; and reject brine (5,15 dS m-1, a wastewater from desalination process. These waters were combined in six treatments resulted from their alternated use to prepare nutrient solution (NS and/or replace the evapotranspiration loss (ETc. The experiment was carried out under a greenhouse condition in the semiarid region of Pernambuco State, Brazil; 48 experimental units were used for both hydroponic systems. The lettuce yield (shoot fresh matter was higher under

  4. Competição de cultivares de alface sob cultivo hidropônico 'NFT' em três diferentes espaçamentos Butterhead lettuce cultivars under 'NFT' hydroponic cultivation in three different spacings

    Directory of Open Access Journals (Sweden)

    Ronan Gualberto

    1999-07-01

    Full Text Available Com o objetivo de avaliar o desempenho de seis cultivares de alface do tipo lisa (Babá de Verão, Brasil 303, Elisa, Karla, Lívia e Monalisa em três espaçamentos (25 x 20, 25 x 25 e 25 x 30 cm, cultivadas em sistema hidropônico 'NFT', realizou-se um experimento na Fazenda Experimental da Universidade de Marília (SP, no período de 23 de setembro a 21 de novembro de 1997. Foram avaliadas as características comprimento de caule, produção de matéria fresca por planta e por área e produção de matéria seca da parte aérea, da raiz e total. O delineamento experimental adotado foi o de blocos casualizados, em esquema fatorial 6 x 3, com três repetições. Não houve efeito significativo da interação entre cultivares e espaçamentos. As cultivares Babá de Verão, Lívia e Elisa se destacaram pela produção de matéria fresca e matéria seca total. As cultivares Monalisa e Karla mostraram-se menos suscetíveis ao pendoamento precoce, enquanto a 'Babá de Verão' foi a mais suscetível. Não foi verificada influência significativa dos espaçamentos sobre as características estudadas, exceto para a produção por área, onde independente das cultivares utilizadas, o espaçamento 25 x 20 propiciou uma produção de 4,465 Kg/m², superior aos demais espaçamentos utilizados. Assim. Produções significativamente inferiores foram obtidas nos tratamentos 25 x 25 cm e 25 x 30 cm: 3,583 e 3,304 Kg/m², respectivamente, devido à redução no número de plantas por m².An experiment was carried out at the Experimental Farm, of Marília University, from September 23th 1997 to November 21st 1997 with the objective of evaluating the performance of six butterhead lettuce cultivars (Babá de Verão, Brasil 303, Elisa, Karla, Lívia and Monalisa in three spacings (25 x 20, 25 x 25 and 25 x 30 cm, cultivated under a hydroponic system 'NFT'. Stem length, fresh matter yield per plant and per area, and aerial part and root dry matter weight were

  5. OpenNFT: An open-source Python/Matlab framework for real-time fMRI neurofeedback training based on activity, connectivity and multivariate pattern analysis.

    Science.gov (United States)

    Koush, Yury; Ashburner, John; Prilepin, Evgeny; Sladky, Ronald; Zeidman, Peter; Bibikov, Sergei; Scharnowski, Frank; Nikonorov, Artem; De Ville, Dimitri Van

    2017-08-01

    Neurofeedback based on real-time functional magnetic resonance imaging (rt-fMRI) is a novel and rapidly developing research field. It allows for training of voluntary control over localized brain activity and connectivity and has demonstrated promising clinical applications. Because of the rapid technical developments of MRI techniques and the availability of high-performance computing, new methodological advances in rt-fMRI neurofeedback become possible. Here we outline the core components of a novel open-source neurofeedback framework, termed Open NeuroFeedback Training (OpenNFT), which efficiently integrates these new developments. This framework is implemented using Python and Matlab source code to allow for diverse functionality, high modularity, and rapid extendibility of the software depending on the user's needs. In addition, it provides an easy interface to the functionality of Statistical Parametric Mapping (SPM) that is also open-source and one of the most widely used fMRI data analysis software. We demonstrate the functionality of our new framework by describing case studies that include neurofeedback protocols based on brain activity levels, effective connectivity models, and pattern classification approaches. This open-source initiative provides a suitable framework to actively engage in the development of novel neurofeedback approaches, so that local methodological developments can be easily made accessible to a wider range of users. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.

  6. Super-rapid medical film processing system

    International Nuclear Information System (INIS)

    Honda, C.; Iwata, M.; Nozaki, H.

    1988-01-01

    A new super-rapid medical film processing system cuts processing time from 90 to 45 seconds, a critical advantage in traumatic injury, surgical operation, and other time-vital applications. The system consists of new films new processing chemicals (developer and fixer), and a new high-speed medical film processor. The system's creation is made possible by three new technologies. In film, multilayered monodispersed grains reduce processing time. In processing chemicals, an innovative design maximizes processing speed. And in the processor itself, a new drying apparatus increases drying efficiency. Together, these technologies achieve 45-second processing without degradation of image quality

  7. PENGENDALIAN KUALITAS PADA RANTAI PASOK SAYURAN SELADA DENGAN TEKNIK BUDIDAYA HIDROPONIK NFT

    Directory of Open Access Journals (Sweden)

    Fristy Yuanita

    2017-07-01

    Full Text Available Tujuan dari penelitian mengenai pengendalian kualitas pada rantai pasok sayuran selada NFT (Nutrient Film Technique adalah untuk melihat kinerja pelaku yang ada dalam rantai pasok sebagai upaya dalam pengendalian kualitas produk dalam bisnis pertanian. Penelitian dilakukan pada PT. Momenta Agrikultura “Amazing Farm” yang berlokasi di Desa Cikahuripan Kampung Cisaroni RT 002/008, Kecamatan Lembang, Kabupaten Bandung Barat, Jawa Barat Indonesia. Desain penelitian yang digunakan dalam penelitian ini adalah desain kualitatif didukung data kuantitatif dengan teknik penelitian yang digunakan adalah studi kasus. Pengambilan sampel yang digunakan adalah metode purposive sampling. Data yang diperoleh adalah data primer dan data sekunder. Analisis data menggunakan analisis deskriptif. Hasil penelitian menunjukkan permasalahan utama adalah kontrak yang tidak memadai serta penanganan yang kasar disebabkan kurangnya pengawasan dan evaluasi kinerja secara rutin, serta pengendalian kualitas proses produksi pada rantai pasok selada dilakukan oleh pemasok dan PT Momenta Agrikultura “Amazing Farm”. Kinerja PT Momenta Agrikultura “Amazing Farm” mendekati empat sigma, yang mana merupakan standar industri Amerika dan melebihi standar kebanyakan industri di Indonesia. Tindakan pada perbaikan dan pengendalian yang diusulkan yaitu pembenahan kontrak, pembagian informasi, perbaikan metode kerja dan mengu-rangi resiko penurunan kualitas dengan Standard Operating Procedure (SOP pada Packing House agar lebih steril, efektif, dan efisien.

  8. MSFC Electrostatic Levitator (ESL) Rapid Quench System

    Science.gov (United States)

    SanSoucie, Michael P.; Craven, Paul D.; Rogers, Jan R.

    2014-01-01

    The NASA Marshall Space Flight Center (MSFC) Electrostatic Levitator (ESL) Laboratory is a unique facility for investigators studying high-temperature materials. The laboratory boasts two levitators in which samples can be levitated, heated, melted, undercooled, and resolidified, all without the interference of a container or data-gathering instrument. The ESL main chamber has been upgraded with the addition of a rapid quench system. This system allows samples to be dropped into a quench vessel that can be filled with a low melting point material, such as a gallium or indium alloy. Thereby allowing rapid quenching of undercooled liquid metals. Up to 8 quench vessels can be loaded into the quench wheel, which is indexed with LabVIEW control software. This allows up to 8 samples to be rapidly quenched before having to open the chamber. The system has been tested successfully on several zirconium samples. Future work will be done with other materials using different quench mediums. Microstructural analysis will also be done on successfully quench samples.

  9. Comparison of Fatty Acid Methyl Ester Analysis with the Use of API 20E and NFT Strips for Identification of Aquatic Bacteria

    OpenAIRE

    Brown, B. J.; Leff, L. G.

    1996-01-01

    Aquatic bacteria grown on MacConkey agar and modified nutrient agar were identified by using API 20E and NFT strips and fatty acid methyl ester (FAME) analysis. Identifications agreed at the species level 35.7% of the time when API 20E strips and FAME analysis were used and in 4.3% of the cases when API NFT strips and FAME analysis were used. These techniques require further development before extended use in ecological studies.

  10. Rapid deployable global sensing hazard alert system

    Science.gov (United States)

    Cordaro, Joseph V; Tibrea, Steven L; Shull, Davis J; Coleman, Jerry T; Shuler, James M

    2015-04-28

    A rapid deployable global sensing hazard alert system and associated methods of operation are provided. An exemplary system includes a central command, a wireless backhaul network, and a remote monitoring unit. The remote monitoring unit can include a positioning system configured to determine a position of the remote monitoring unit based on one or more signals received from one or more satellites located in Low Earth Orbit. The wireless backhaul network can provide bidirectional communication capability independent of cellular telecommunication networks and the Internet. An exemplary method includes instructing at least one of a plurality of remote monitoring units to provide an alert based at least in part on a location of a hazard and a plurality of positions respectively associated with the plurality of remote monitoring units.

  11. Heliopause Electrostatic Rapid Transit System (HERTS)

    Science.gov (United States)

    Wiegmann, Bruce M.

    2015-01-01

    A recent six month investigation focused on: "Determining the benefits of propelling a scientific spacecraft by an 'Electric Sail' propulsion system to the edge of our solar system (the Heliopause), a distance of 100 to 120 AU, in ten years or less" has recently been completed by the Advance Concepts Office at NASA's MSFC. The concept investigated has been named the Heliopause Electrostatic Rapid Transit System (HERTS) by the MSFC team. The HERTS is a revolutionary propellant-less propulsion concept that is ideal for deep space missions to the Outer Planets, Heliopause, and beyond. It is unique in that it uses momentum exchange from naturally occurring solar wind protons to propel a spacecraft within the heliosphere. The propulsion system consists of an array of electrically positively-biased wires that extend outward 20 km from a rotating (one revolution per hour) spacecraft. It was determined that the HERTS system can accelerate a spacecraft to velocities as much as two to three times that possible by any realistic extrapolation of current state-of-the-art propulsion technologies- including solar electric and solar sail propulsion systems. The data produced show that a scientific spacecraft could reach distances of 100AU in less than 10 years. Moreover, it can be reasonably expected that this system could be developed within a decade and provide meaningful Heliophysics Science and Outer Planetary Science returns in the 2025-2035 timeframe.

  12. Hallmarks of Alzheimer disease are evolving relentlessly in Metropolitan Mexico City infants, children and young adults. APOE4 carriers have higher suicide risk and higher odds of reaching NFT stage V at ≤ 40 years of age.

    Science.gov (United States)

    Calderón-Garcidueñas, Lilian; Gónzalez-Maciel, Angélica; Reynoso-Robles, Rafael; Delgado-Chávez, Ricardo; Mukherjee, Partha S; Kulesza, Randy J; Torres-Jardón, Ricardo; Ávila-Ramírez, José; Villarreal-Ríos, Rodolfo

    2018-07-01

    Exposures to fine particulate matter (PM 2.5 ) and ozone (O 3 ) above USEPA standards are associated with Alzheimer's disease (AD) risk. Metropolitan Mexico City (MMC) residents have life time exposures to PM 2.5 and O 3 above USEPA standards. We investigated AD intra and extracellular protein aggregates and ultrastructural neurovascular pathology in 203 MMC residents age 25.36 ± 9.23 y. Immunohistochemical methods were used to identify AT8 hyperphosphorilated tau (Htau) and 4G8 (amyloid β 17-24). Primary outcomes: staging of Htau and amyloid, per decade and cumulative PM 2.5 (CPM 2.5 ) above standard. Apolipoprotein E allele 4 (APOE4), age and cause of death were secondary outcomes. Subcortical pretangle stage b was identified in an 11month old baby. Cortical tau pre-tangles, neurofibrillary tangles (NFT) Stages I-II, amyloid phases 1-2, Htau in substantia nigrae, auditory, oculomotor, trigeminal and autonomic systems were identified by the 2nd decade. Progression to NFT stages III-V was present in 24.8% of 30-40 y old subjects. APOE4 carriers have 4.92 times higher suicide odds (p = 0.0006), and 23.6 times higher odds of NFT V (p < 0.0001) v APOE4 non-carriers having similar CPM 2.5 exposure and age. Age (p = 0.0062) and CPM 2.5 (p = 0.0178) were significant for developing NFT V. Combustion-derived nanoparticles were associated with early and progressive damage to the neurovascular unit. Alzheimer's disease starting in the brainstem of young children and affecting 99.5% of young urbanites is a serious health crisis. Air pollution control should be prioritised. Childhood relentless Htau makes a fundamental target for neuroprotective interventions and the first two decades are critical. We recommend the concept of preclinical AD be revised and emphasize the need to define paediatric environmental, nutritional, metabolic and genetic risk factor interactions of paramount importance to prevent AD. AD evolving from childhood is threating the

  13. Micro rapid prototyping system for micro components

    International Nuclear Information System (INIS)

    Li Xiaochun; Choi Hongseok; Yang Yong

    2002-01-01

    Similarities between silicon-based micro-electro-mechanical systems (MEMS) and Shape Deposition Manufacturing (SDM) processes are obvious: both integrate additive and subtractive processes and use part and sacrificial materials to obtain functional structures. These MEMS techniques are two-dimensional (2-D) processes for a limited number of materials while SDM enables the building of parts that have traditionally been impossible to fabricate because of their complex shapes or of their variety in materials. This work presents initial results on the development of a micro rapid prototyping system that adapts SDM methodology to micro-fabrication. This system is designed to incorporate microdeposition and laser micromachining. In the hope of obtaining a precise microdeposition, an ultrasonic-based micro powder-feeding mechanism was developed in order to form thin patterns of dry powders that can be cladded or sintered onto a substrate by a micro-sized laser beam. Furthermore, experimental results on laser micromachining using a laser beam with a wavelength of 355 nm are also presented. After further improvement, the developed micro manufacturing system could take computer-aided design (CAD) output to reproduce 3-D heterogeneous micro-components from a wide selection of materials

  14. RAPID DYNAMICAL CHAOS IN AN EXOPLANETARY SYSTEM

    Energy Technology Data Exchange (ETDEWEB)

    Deck, Katherine M.; Winn, Joshua N. [Department of Physics and Kavli Institute for Astrophysics and Space Research, Massachusetts Institute of Technology, 77 Massachusetts Avenue, Cambridge, MA 02139 (United States); Holman, Matthew J.; Carter, Joshua A.; Ragozzine, Darin [Harvard-Smithsonian Center for Astrophysics, 60 Garden Street, Cambridge, MA 02138 (United States); Agol, Eric [Department of Astronomy, Box 351580, University of Washington, Seattle, WA 98195 (United States); Lissauer, Jack J. [NASA Ames Research Center, Moffet Field, CA 94035 (United States)

    2012-08-10

    We report on the long-term dynamical evolution of the two-planet Kepler-36 system, which consists of a super-Earth and a sub-Neptune in a tightly packed orbital configuration. The orbits of the planets, which we studied through numerical integrations of initial conditions that are consistent with observations of the system, are chaotic with a Lyapunov time of only {approx}10 years. The chaos is a consequence of a particular set of orbital resonances, with the inner planet orbiting 34 times for every 29 orbits of the outer planet. The rapidity of the chaos is due to the interaction of the 29:34 resonance with the nearby first-order 6:7 resonance, in contrast to the usual case in which secular terms in the Hamiltonian play a dominant role. Only one contiguous region of phase space, accounting for {approx}4.5% of the sample of initial conditions studied, corresponds to planetary orbits that do not show large-scale orbital instabilities on the timescale of our integrations ({approx}200 million years). Restricting the orbits to this long-lived region allows a refinement of estimates of the masses and radii of the planets. We find that the long-lived region consists of the initial conditions that satisfy the Hill stability criterion by the largest margin. Any successful theory for the formation of this system will need to account for why its current state is so close to unstable regions of phase space.

  15. Experiencia de producción de lechuga americana (Lactuca sativa hidropónica, tipo NFT

    Directory of Open Access Journals (Sweden)

    Laura Brenes-Peralta

    2014-06-01

    En el Centro de Prácticas Docentes e Investigación Agropecuaria de la Escuela de Agronegocios del Instituto Tecnológico de Costa Rica (TEC se cuenta, actualmente, con un sistema de este tipo NFT donde estableció una actividad de fortalecimiento que ha resultado en la observación de ciertas características a partir de la experiencia generada, de la cual se espera fomentar el uso de la hidroponía, así como divulgar información técnica y de buenas prácticas en este tipo de cultivo entre usuarios interesados.

  16. Rapid scanning system for fuel drawers

    International Nuclear Information System (INIS)

    Caldwell, J.T.; Fehlau, P.E.; France, S.W.

    1981-01-01

    A nondestructive method for uniqely distinguishing among and quantifying the mass of individual fuel plates in situ in fuel drawers utilized in nuclear reactors is described. The method is both rapid and passive, eliminating the personnel hazard of the commonly used irradiation techniques which require that the analysis be performed in proximity to an intense neutron source such as a reactor. In the present technique, only normally decaying nuclei are observed. This allows the analysis to be performed anywhere. This feature, combined with rapid scanning of a given fuel drawer (in approximately 30 s), and the computer data analysis allows the processing of large numbers of fuel drawers efficiently in the event of a loss alert

  17. An automatic injection system for rapid radiochemistry

    International Nuclear Information System (INIS)

    Nurmia, M.J.; Kreek, S.A.; Kadkhodayan, B.; Gregorich, K.E.; Lee, D.M.; Hoffman, D.C.

    1992-01-01

    A description is given of the Automated Injection System (AIS), a pneumatically actuated device for automated collection of nuclear reaction products from a He/KCl gas jet transport system. The AIS is used with the Automated Chemical Chromatographic Element Separation System; together these two devices facilitate completely automated separation procedures with improved speed and reproducibility

  18. Rapid surface sampling and archival record system

    Energy Technology Data Exchange (ETDEWEB)

    Barren, E.; Penney, C.M.; Sheldon, R.B. [GE Corporate Research and Development Center, Schenectady, NY (United States)] [and others

    1995-10-01

    A number of contamination sites exist in this country where the area and volume of material to be remediated is very large, approaching or exceeding 10{sup 6} m{sup 2} and 10{sup 6} m{sup 3}. Typically, only a small fraction of this material is actually contaminated. In such cases there is a strong economic motivation to test the material with a sufficient density of measurements to identify which portions are uncontaminated, so extensively they be left in place or be disposed of as uncontaminated waste. Unfortunately, since contamination often varies rapidly from position to position, this procedure can involve upwards of one million measurements per site. The situation is complicated further in many cases by the difficulties of sampling porous surfaces, such as concrete. This report describes a method for sampling concretes in which an immediate distinction can be made between contaminated and uncontaminated surfaces. Sample acquisition and analysis will be automated.

  19. Rapid Prototyping of Formally Modelled Distributed Systems

    OpenAIRE

    Buchs, Didier; Buffo, Mathieu; Titsworth, Frances M.

    1999-01-01

    This paper presents various kinds of prototypes, used in the prototyping of formally modelled distributed systems. It presents the notions of prototyping techniques and prototype evolution, and shows how to relate them to the software life-cycle. It is illustrated through the use of the formal modelling language for distributed systems CO-OPN/2.

  20. An Introduction to Rapid System Prototyping

    OpenAIRE

    Luqi; Kordon, Fabrice

    2002-01-01

    IEEE Transactions on Software Engineering, Vol. 28, No. 9, pp. 817–821. The implementation and maintenance of industrial applications have continuously become more and more difficult. In this context, one problem is the evaluation of complex systems. The IEEE defines Prototyping as a development approach promoting the implementation of a pilot version of the intended product. This approach is a potential solution to the early evaluation of a system. It can also be used to avoid th...

  1. Adsorption of Chloroform by the Rapid Response System Filter

    National Research Council Canada - National Science Library

    Karwacki, Christopher

    1997-01-01

    Adsorption equilibria and dynamic breakthrough data were measured to determine the adsorption capacity and effect of purge air on the desorption of chloroform from activated carbon simulating the Rapid Response System (RRS) filter...

  2. NASA MSFC Electrostatic Levitator (ESL) Rapid Quench System

    Science.gov (United States)

    SanSoucie, Michael P.; Craven, Paul D.

    2014-01-01

    Electrostatic levitation, a form of containerless processing, is an important tool in materials research. Levitated specimens are free from contact with a container; therefore, heterogeneous nucleation on container walls is not possible. This allows studies of deeply undercooled melts. Furthermore, studies of high-temperature, highly reactive materials are also possible. Studies of the solidification and crystallization of undercooled melts is vital to the understanding of microstructure development, particularly the formation of alloys with unique properties by rapid solidification. The NASA Marshall Space Flight Center (MSFC) Electrostatic Levitator (ESL) lab has recently been upgraded to allow for rapid quenching of levitated materials. The ESL Rapid Quench System uses a small crucible-like vessel that can be partially filled with a low melting point material, such as a Gallium alloy, as a quench medium. An undercooled sample can be dropped into the vessel to rapidly quench the sample. A carousel with nine vessels sits below the bottom electrode assembly. This system allows up to nine rapid quenches before having to break vacuum and remove the vessels. This new Rapid Quench System will allow materials science studies of undercooled materials and new materials development. In this presentation, the system is described and initial results are presented.

  3. Estratégias de uso de água salobra na produção de alface em hidroponia NFT Strategies for use of brackish water in NFT hydroponic lettuce production

    Directory of Open Access Journals (Sweden)

    Márcio S. Alves

    2011-05-01

    Full Text Available Plantas de alface crespa 'Verônica' foram cultivadas em condições hidropônicas, objetivando avaliar três diferentes estratégias de emprego de águas salobras: 1 águas salobras para reposição das perdas por evapotranspiração (ETc e água doce para o preparo da solução nutritiva (SN; 2 águas salobras para o preparo da SN e água doce para reposição da ETc; 3 águas salobras para o preparo da SN e reposição da ETc. Os níveis de salinidade da água foram obtidos pela adição de NaCl à água doce (0,27 dS m-1: 1,45; 2,51; 3,6; 5,41 e 7,5 dS m-1. O experimento foi conduzido em quatro blocos aleatorizados, com quatro repetições por tratamento. Uma estrutura de pesquisa foi construída com 72 parcelas que simulam a técnica do fluxo laminar de nutrientes (NFT. O uso de água salobra apenas para repor a ETc não produziu efeito sobre a produção da alface. Por outro lado, o uso de águas salobras para o preparo da SN e água doce para reposição da ETc, reduziu o rendimento da alface (massa de matéria fresca da parte aérea em 4,99% por (dS m-1. O rendimento foi reduzido em 7% por dS m-1 quando águas salobras foram usadas tanto para o preparo da SN quanto para reposição da ETc. Apesar da redução linear da produção da alface com o aumento da salinidade da água, sintomas depreciativos para a qualidade da alface hidropônica não foram registrados.Plants of crisphead lettuce cv. 'Verônica' were grown under hydroponic conditions aiming to evaluate three different strategies of brackish waters utilization: 1 brackish waters to replace the evapotranspiration loss (ETc and fresh water to prepare nutrient solution (NS; 2 brackish waters to prepare NS and fresh water to replace the ETc; 3 brackish waters to prepare NS and replace ETc. The levels of water salinity were obtained by addition of NaCl to fresh water (0.27 dS m-1: 1.45; 2.51; 3.6; 5.41 and 7.5 dS m-1. The experiment was conducted in randomized blocks with four

  4. Research and Development of Rapid Design Systems for Aerospace Structure

    Science.gov (United States)

    Schaeffer, Harry G.

    1999-01-01

    This report describes the results of research activities associated with the development of rapid design systems for aerospace structures in support of the Intelligent Synthesis Environment (ISE). The specific subsystems investigated were the interface between model assembly and analysis; and, the high performance NASA GPS equation solver software system in the Windows NT environment on low cost high-performance PCs.

  5. Structure Design and Realization of Rapid Medicine Dispensing System

    Science.gov (United States)

    Liu, Xiangquan

    In this paper, the main components and function of rapid medicine dispensing system is analyzed, structure design of automatic feeding device, sloping storeroom, automatic dispensing device and automatic sorting device is completed. The system adopts medicine conveyer working in with manipulator to realize automatic batch supply of the boxed medicine, adopts sloping storeroom as warehouse of medicine to realize dense depositing, adopts dispensing mechanism which includes elevator, turning panel and electric magnet to realize rapid medicine dispensing, adopts sorting conveyor belt and sorting device to send medicine to designated outlet.

  6. Logic Foundry: Rapid Prototyping for FPGA-Based DSP Systems

    Directory of Open Access Journals (Sweden)

    Bhattacharyya Shuvra S

    2003-01-01

    Full Text Available We introduce the Logic Foundry, a system for the rapid creation and integration of FPGA-based digital signal processing systems. Recognizing that some of the greatest challenges in creating FPGA-based systems occur in the integration of the various components, we have proposed a system that targets the following four areas of integration: design flow integration, component integration, platform integration, and software integration. Using the Logic Foundry, a system can be easily specified, and then automatically constructed and integrated with system level software.

  7. Rapid Conditioning for the Next Generation Melting System

    Energy Technology Data Exchange (ETDEWEB)

    Rue, David M. [Gas Technology Institute, Des Plaines, IL (United States)

    2015-06-17

    This report describes work on Rapid Conditioning for the Next Generation Melting System under US Department of Energy Contract DE-FC36-06GO16010. The project lead was the Gas Technology Institute (GTI). Partners included Owens Corning and Johns Manville. Cost share for this project was provided by NYSERDA (the New York State Energy Research and Development Authority), Owens Corning, Johns Manville, Owens Illinois, and the US natural gas industry through GTI’s SMP and UTD programs. The overreaching focus of this project was to study and develop rapid refining approaches for segmented glass manufacturing processes using high-intensity melters such as the submerged combustion melter. The objectives of this project were to 1) test and evaluate the most promising approaches to rapidly condition the homogeneous glass produced from the submerged combustion melter, and 2) to design a pilot-scale NGMS system for fiberglass recycle.

  8. Internal validation of the RapidHIT® ID system.

    Science.gov (United States)

    Wiley, Rachel; Sage, Kelly; LaRue, Bobby; Budowle, Bruce

    2017-11-01

    Traditionally, forensic DNA analysis has required highly skilled forensic geneticists in a dedicated laboratory to generate short tandem repeat (STR) profiles. STR profiles are routinely used either to associate or exclude potential donors of forensic biological evidence. The typing of forensic reference samples has become more demanding, especially with the requirement in some jurisdictions to DNA profile arrestees. The Rapid DNA (RDNA) platform, the RapidHIT ® ID (IntegenX ® , Pleasanton, CA), is a fully automated system capable of processing reference samples in approximately 90min with minimal human intervention. Thus, the RapidHIT ID instrument can be deployed to non-laboratory environments (e.g., booking stations) and run by trained atypical personnel such as law enforcement. In order to implement the RapidHIT ID platform, validation studies are needed to define the performance and limitations of the system. Internal validation studies were undertaken with four early-production RapidHIT ID units. Reliable and concordant STR profiles were obtained from reference buccal swabs. Throughout the study, no contamination was observed. The overall first-pass success rate with an "expert-like system" was 72%, which is comparable to another current RDNA platform commercially available. The system's second-pass success rate (involving manual interpretation on first-pass inconclusive results) increased to 90%. Inhibitors (i.e., coffee, smoking tobacco, and chewing tobacco) did not appear to affect typing by the instrument system; however, substrate (i.e., swab type) did impact typing success. Additionally, one desirable feature not available with other Rapid systems is that in the event of a system failed run, a swab can be recovered and subsequently re-analyzed in a new sample cartridge. Therefore, rarely should additional sampling or swab consumption be necessary. The RapidHIT ID system is a robust and reliable tool capable of generating complete STR profiles within

  9. Microelectromechanical high-density energy storage/rapid release system

    Science.gov (United States)

    Rodgers, M. Steven; Allen, James J.; Meeks, Kent D.; Jensen, Brian D.; Miller, Samuel L.

    1999-08-01

    One highly desirable characteristic of electrostatically driven microelectromechanical systems (MEMS) is that they consume very little power. The corresponding drawback is that the force they produce may be inadequate for many applications. It has previously been demonstrated that gear reduction units or microtransmissions can substantially increase the torque generated by microengines. Operating speed, however, is also reduced by the transmission gear ratio. Some applications require both high speed and high force. If this output is only required for a limited period of time, then energy could be stored in a mechanical system and rapidly released upon demand. We have designed, fabricated, and demonstrated a high-density energy storage/rapid release system that accomplishes this task. Built using a 5-level surface micromachining technology, the assembly closely resembles a medieval crossbow. Energy releases on the order of tens of nanojoules have already been demonstrated, and significantly higher energy systems are under development.

  10. A Rapid Prototyping Environment for Wireless Communication Embedded Systems

    Directory of Open Access Journals (Sweden)

    Bryan A. Jones

    2003-05-01

    Full Text Available This paper introduces a rapid prototyping methodology which overcomes important barriers in the design and implementation of digital signal processing (DSP algorithms and systems on embedded hardware platforms, such as cellular phones. This paper describes rapid prototyping in terms of a simulation/prototype bridge and in terms of appropriate language design. The simulation/prototype bridge combines the strengths of simulation and of prototyping, allowing the designer to develop and evaluate next-generation communications systems, partly in simulation on a host computer and partly as a prototype on embedded hardware. Appropriate language design allows designers to express a communications system as a block diagram, in which each block represents an algorithm specified by a set of equations. Software tools developed for this paper implement both concepts, and have been successfully used in the development of a next-generation code division multiple access (CDMA cellular wireless communications system.

  11. Performance of the efferent limb of a rapid response system

    DEFF Research Database (Denmark)

    Sørensen, Emilie M; Petersen, Asger

    2015-01-01

    AIM: To determine the distribution of outcomes following a medical emergency team (MET) call using a modified version of the multidisciplinary audit and evaluation of outcomes of rapid response (MAELOR) tool, and to evaluate its usefulness in monitoring the performance of the efferent limb...... of the rapid response system (RRS) at our institution. METHOD: An observational study of prospectively collected data including all MET calls at our institution during the 36 weeks study period (23 December 2013 - 31 august 2014). Outcomes of MET calls were registered 24 h after the call occurred...

  12. MedRapid--medical community & business intelligence system.

    Science.gov (United States)

    Finkeissen, E; Fuchs, H; Jakob, T; Wetter, T

    2002-01-01

    currently, it takes at least 6 months for researchers to communicate their results. This delay is caused (a) by partial lacks of machine support for both representation as well as communication and (b) by media breaks during the communication process. To make an integrated communication between researchers and practitioners possible, a general structure for medical content representation has been set up. The procedure for data entry and quality management has been generalized and implemented in a web-based authoring system. The MedRapid-system supports the medical experts in entering their knowledge into a database. Here, the level of detail is still below that of current medical guidelines representation. However, the symmetric structure for an area-wide medical knowledge representation is highly retrievable and thus can quickly be communicated into daily routine for the improvement of the treatment quality. In addition, other sources like journal articles and medical guidelines can be references within the MedRapid-system and thus be communicated into daily routine. The fundamental system for the representation of medical reference knowledge (from reference works/books) itself is not sufficient for the friction-less communication amongst medical staff. Rather, the process of (a) representing medical knowledge, (b) refereeing the represented knowledge, (c) communicating the represented knowledge, and (d) retrieving the represented knowledge has to be unified. MedRapid will soon support the whole process on one server system.

  13. Rapid preparation of functional polysaccharides from Pyropia yezoensis by microwave-assistant rapid enzyme digest system.

    Science.gov (United States)

    Lee, Ji-Hyeok; Kim, Hyung-Ho; Ko, Ju-Young; Jang, Jun-Ho; Kim, Gwang-Hoon; Lee, Jung-Suck; Nah, Jae-Woon; Jeon, You-Jin

    2016-11-20

    This study describes a simple preparation of functional polysaccharides from Pyropia yezoensis using a microwave-assistant rapid enzyme digest system (MAREDS) with various carbohydrases, and evaluates their antioxidative effects. Polysaccharide hydrolysates were prepared using MAREDS under different hydrolytic conditions of the carbohydrases and microwave powers. Polysaccharides less than 10kDa (Low molecular weight polysaccharides, LMWP, ≤10kDa) were efficiently obtained using an ultrafiltration (molecular weight cut-off of 10kDa). MAREDS increases AMG activation via an increased degree of hydrolysis; the best AMG hydrolysate was prepared using a 10:1 ratio of substrate to enzyme for 2h in MAREDS with 400W. LMWP consisted of galactose (27.3%), glucose (64.5%), and mannose (8.3%) from the AMG hydrolysate had stronger antioxidant effects than the high molecular weight polysaccharides (>10kDa). We rapidly prepared functional LMWPs by using MAREDS with carbohydrases, and suggest that LMWP might be potentially a valuable algal polysaccharide antioxidant. Copyright © 2016 Elsevier Ltd. All rights reserved.

  14. UNMANNED AIRCRAFT SYSTEMS FOR RAPID NEAR SURFACE GEOPHYSICAL MEASUREMENTS

    Directory of Open Access Journals (Sweden)

    J. B. Stoll

    2013-08-01

    Full Text Available This paper looks at some of the unmanned aircraft systems (UAS options and deals with a magnetometer sensor system which might be of interest in conducting rapid near surface geophysical measurements. Few of the traditional airborne geophysical sensors are now capable of being miniaturized to sizes and payload within mini UAS limits (e.g. airborne magnetics, gamma ray spectrometer. Here the deployment of a fluxgate magnetometer mounted on an UAS is presented demonstrating its capability of detecting metallic materials that are buried in the soil. The effectiveness in finding ferrous objects (e.g. UXO, landslides is demonstrated in two case studies.

  15. The limitations in implementing and operating a rapid response system.

    Science.gov (United States)

    Subramaniam, A; Botha, J; Tiruvoipati, R

    2016-10-01

    Despite the widespread introduction of rapid response systems (RRS)/medical emergency teams (MET), there is still controversy regarding how effective they are. While there are some observational studies showing improved outcomes with RRS, there are no data from randomised controlled trials to support the effectiveness. Nevertheless, the MET system has become a standard of care in many healthcare organisations. In this review, we present an overview of the limitations in implementing and operating a RRS in modern healthcare. © 2016 Royal Australasian College of Physicians.

  16. Production de minitubercules de pomme de terre par hydroponie: évaluation d'un système combinant les techniques NFT et Gravel Culture pour deux types de solutions nutritives

    Directory of Open Access Journals (Sweden)

    Rolot J.L.

    2002-01-01

    Full Text Available Potato minituber production through hydropony: assessment of a system combining the NFT and Gravel Culture techniques for two types of nutrient solutions. The potato minituber production is the classical intermediate stage enabling field use of potato materials with an in vitro origin. This production of minitubers may be achieved through various techniques. Most often however they are based upon bedding vitroplantlets or vitroplantlets cuttings in an organic substratum which is disinfected or not. The soilless culture of plants stemming from vitrotubers to produce minitubers with a superior health quality was tested within a hydroponic system. Two types of nutrient solutions were compared: a nitrogen rich one (NPK, mg/l, 180-40-300 and a phosphorus rich one (NPK, mg/l, 60-150-300. In order to initiate the cultures, presprouting microtubers of several varieties (Bintje, Kennebec, Spunta, Saturna, Desiree and Gasore were used. Multiplication rates ranged between 13.2 (Saturna and 3.8 (Kennebec minitubers with a grade higher than 10 mm (more than 1.5 g. As the selected density of the plants was 59 plants per square metre, the yield per square metre varied from 224 to 779 minitubers with a grade higher than 10 mm. The obtained number of minitubers depended especially on the variety. The phosphorus enrichment of the nutrient solution induced an increased number of minitubers produced with a grade higher than 15 mm (more than 5 g. The health state of the produced tubers was excellent.

  17. Global Rapid Flood Mapping System with Spaceborne SAR Data

    Science.gov (United States)

    Yun, S. H.; Owen, S. E.; Hua, H.; Agram, P. S.; Fattahi, H.; Liang, C.; Manipon, G.; Fielding, E. J.; Rosen, P. A.; Webb, F.; Simons, M.

    2017-12-01

    As part of the Advanced Rapid Imaging and Analysis (ARIA) project for Natural Hazards, at NASA's Jet Propulsion Laboratory and California Institute of Technology, we have developed an automated system that produces derived products for flood extent map generation using spaceborne SAR data. The system takes user's input of area of interest polygons and time window for SAR data search (pre- and post-event). Then the system automatically searches and downloads SAR data, processes them to produce coregistered SAR image pairs, and generates log amplitude ratio images from each pair. Currently the system is automated to support SAR data from the European Space Agency's Sentinel-1A/B satellites. We have used the system to produce flood extent maps from Sentinel-1 SAR data for the May 2017 Sri Lanka floods, which killed more than 200 people and displaced about 600,000 people. Our flood extent maps were delivered to the Red Cross to support response efforts. Earlier we also responded to the historic August 2016 Louisiana floods in the United States, which claimed 13 people's lives and caused over $10 billion property damage. For this event, we made synchronized observations from space, air, and ground in close collaboration with USGS and NOAA. The USGS field crews acquired ground observation data, and NOAA acquired high-resolution airborne optical imagery within the time window of +/-2 hours of the SAR data acquisition by JAXA's ALOS-2 satellite. The USGS coordinates of flood water boundaries were used to calibrate our flood extent map derived from the ALOS-2 SAR data, and the map was delivered to FEMA for estimating the number of households affected. Based on the lessons learned from this response effort, we customized the ARIA system automation for rapid flood mapping and developed a mobile friendly web app that can easily be used in the field for data collection. Rapid automatic generation of SAR-based global flood maps calibrated with independent observations from

  18. Recent Ground Hold and Rapid Depressurization Testing of Multilayer Systems

    Science.gov (United States)

    Johnson, Wesley L.

    2014-01-01

    In the development of flight insulation systems for large cryogenic orbital storage (spray on foam and multilayer insulation), testing need include all environments that are experienced during flight. While large efforts have been expended on studying, bounding, and modeling the orbital performance of the insulation systems, little effort has been expended on the ground hold and ascent phases of a mission. Historical cryogenic in-space systems that have flown have been able to ignore these phases of flight due to the insulation system being within a vacuum jacket. In the development phase of the Nuclear Mars Vehicle and the Shuttle Nuclear Vehicle, several insulation systems were evaluated for the full mission cycle. Since that time there had been minimal work on these phases of flight until the Constellation program began investigating cryogenic service modules and long duration upper stages. With the inception of the Cryogenic Propellant Storage and Transfer Technology Demonstration Mission, a specific need was seen for the data and as such, several tests were added to the Cryogenic Boil-off Reduction System liquid hydrogen test matrix to provide more data on a insulation system. Testing was attempted with both gaseous nitrogen (GN2) and gaseous helium (GHe) backfills. The initial tests with nitrogen backfill were not successfully completed due to nitrogen liquefaction and solidification preventing the rapid pumpdown of the vacuum chamber. Subsequent helium backfill tests were successful and showed minimal degradation. The results are compared to the historical data.

  19. Rapid hyperspectral image classification to enable autonomous search systems

    Directory of Open Access Journals (Sweden)

    Raj Bridgelal

    2016-11-01

    Full Text Available The emergence of lightweight full-frame hyperspectral cameras is destined to enable autonomous search vehicles in the air, on the ground and in water. Self-contained and long-endurance systems will yield important new applications, for example, in emergency response and the timely identification of environmental hazards. One missing capability is rapid classification of hyperspectral scenes so that search vehicles can immediately take actions to verify potential targets. Onsite verifications minimise false positives and preclude the expense of repeat missions. Verifications will require enhanced image quality, which is achievable by either moving closer to the potential target or by adjusting the optical system. Such a solution, however, is currently impractical for small mobile platforms with finite energy sources. Rapid classifications with current methods demand large computing capacity that will quickly deplete the on-board battery or fuel. To develop the missing capability, the authors propose a low-complexity hyperspectral image classifier that approaches the performance of prevalent classifiers. This research determines that the new method will require at least 19-fold less computing capacity than the prevalent classifier. To assess relative performances, the authors developed a benchmark that compares a statistic of library endmember separability in their respective feature spaces.

  20. Design review report for the SY-101 RAPID mitigation system

    International Nuclear Information System (INIS)

    SCHLOSSER, R.L.

    1999-01-01

    This report documents design reviews conducted of the SY-101 Respond And Pump In Days (RAPID) Mitigation System. As part of the SY-101 Surface-Level-Rise Remediation Project, the SY-101 WID Mitigation System will reduce the potential unacceptable consequences of crust growth in Tank 241-SY-101 (SY-101). Projections of the crust growth rate indicate that the waste level in the tank may reach the juncture of the primary and secondary confinement structures of the tank late in 1999. Because of this time constraint, many design activities are being conducted in parallel and design reviews were conducted for system adequacy as well as design implementation throughout the process. Design implementation, as used in this design review report, is the final component selection (e.g., which circuit breaker, valve, or thermocouple) that meets the approved design requirements, system design, and design and procurement specifications. Design implementation includes the necessary analysis, testing, verification, and qualification to demonstrate compliance with the system design and design requirements. Design implementation is outside the scope of this design review. The design activities performed prior to detailed design implementation (i.e., system mission requirements, functional design requirements, technical criteria, system conceptual design, and where design and build contracts were placed, the procurement specification) have been reviewed and are within the scope of this design review report. Detailed design implementation will be controlled, reviewed, and where appropriate, approved in accordance with Tank Waste Remediation System (TWRS) engineering procedures. Review of detailed design implementation will continue until all components necessary to perform the transfer function are installed and tested

  1. Design review report for the SY-101 RAPID mitigation system

    Energy Technology Data Exchange (ETDEWEB)

    SCHLOSSER, R.L.

    1999-05-24

    This report documents design reviews conducted of the SY-101 Respond And Pump In Days (RAPID) Mitigation System. As part of the SY-101 Surface-Level-Rise Remediation Project, the SY-101 WID Mitigation System will reduce the potential unacceptable consequences of crust growth in Tank 241-SY-101 (SY-101). Projections of the crust growth rate indicate that the waste level in the tank may reach the juncture of the primary and secondary confinement structures of the tank late in 1999. Because of this time constraint, many design activities are being conducted in parallel and design reviews were conducted for system adequacy as well as design implementation throughout the process. Design implementation, as used in this design review report, is the final component selection (e.g., which circuit breaker, valve, or thermocouple) that meets the approved design requirements, system design, and design and procurement specifications. Design implementation includes the necessary analysis, testing, verification, and qualification to demonstrate compliance with the system design and design requirements. Design implementation is outside the scope of this design review. The design activities performed prior to detailed design implementation (i.e., system mission requirements, functional design requirements, technical criteria, system conceptual design, and where design and build contracts were placed, the procurement specification) have been reviewed and are within the scope of this design review report. Detailed design implementation will be controlled, reviewed, and where appropriate, approved in accordance with Tank Waste Remediation System (TWRS) engineering procedures. Review of detailed design implementation will continue until all components necessary to perform the transfer function are installed and tested.

  2. Rapid surface sampling and archival record system (RSSAR)

    International Nuclear Information System (INIS)

    Barren, E.; Bracco, A.; Dorn, S.B.

    1997-01-01

    Purpose is to develop a rapid surface (concrete, steel) contamination measurement system that will provide a ''quick-look'' indication of contamination areas, an archival record, and an automated analysis. A bulk sampling oven is also being developed. The sampling device consists of a sampling head, a quick look detector, and an archiving system (sorbent tube). The head thermally desorbs semi-volatiles, such as PCBs, oils, etc., from concrete and steel surfaces; the volatilized materials are passed through a quick-look detector. Sensitivity of the detector can be attenuated for various contaminant levels. Volatilized materials are trapped in a tube filled with adsorbent. The tubes are housed in a magazine which also archives information about sampling conditions. Analysis of the tubes can be done at a later date. The concrete sampling head is fitted with a tungsten-halogen lamp; in laboratory experiments it has extracted model contaminants by heating the top 4mm of the surface to 250 C within 100-200 s. The steel sampling head has been tested on different types of steels and has extracted model contaminants within 30 s. A mathematical model of heat and mass transport in concrete has been developed. Rate of contaminant removal is at maximum when the moisture content is about 100 kg/m 3 . The system will be useful during decontamination and decommissioning operations

  3. A rapid method of evaluating fluoroscopic system performance

    International Nuclear Information System (INIS)

    Sprawls, P.

    1989-01-01

    This paper presents a study to develop a method for the rapid evaluation and documentation of fluoroscopic image quality. All objects contained within a conventional contrast-detail test phantom (Leeds TO-10) are displayed in an array format according to their contrast and size. A copy of the display is used as the data collection form and a permanent record of system performance. A fluoroscope is evaluated by viewing the test phantom and marking the visible objects on the display. A line drawn through the objects with minimum visibility in each size group forms a contrast-detail curve for the system. This is compared with a standard or reference line, which is in the display.Deviations in curve position are useful indicators of specific image quality problems, such as excessive noise or blurring. The use of a special object-visibility array format display makes it possible to collect data, analyze the results, and create a record of fluoroscopic performance in less than 2 minutes for each viewing mode

  4. Rapid density-measurement system with vibrating-tube densimeter

    International Nuclear Information System (INIS)

    Kayukawa, Yohei; Hasumoto, Masaya; Watanabe, Koichi

    2003-01-01

    Concerning an increasing demand for environmentally friendly refrigerants including hydrocarbons, thermodynamic properties of such new refrigerants, especially densities, are essential information for refrigeration engineering. A rapid density-measurement system with vibrating-tube densimeter was developed in the present study with an aim to supply large numbers of high-quality PVT property data in a short period. The present system needs only a few minutes to obtain a single datum, and requires less than 20 cm 3 sample fluid. PVT properties in the entire fluid-phase, vapor-pressures, saturated-liquid densities for pure fluid are available. Liquid densities, bubble-point pressures and saturated-liquid densities for mixture can be obtained. The measurement range is from 240 to 380 K for temperature and up to 7 MPa for pressure. By employing a new calibration function, density can be precisely obtained even at lower densities. The densimeter is calibrated with pure water and iso-octane which is one of the density-standard fluids, and then measurement uncertainty was evaluated to be 0.1 kg m -3 or 0.024% whichever greater in density, 0.26 kPa or 0.022% whichever greater in pressure and 3 mK for temperature, respectively. The performance of the present measurement system was examined by measuring thermodynamic properties for refrigerant R134a. The experimental results were compared with available equation of state and confirmed to agree with it within ±0.05% for liquid densities while ±0.5% in pressure for the gas phase

  5. Rapid Cycle Amine (RCA) 3.0 System Development

    Science.gov (United States)

    Chullen, Cinda; Campbell, Colin; Papale, William; Hawes, Kevin; Wichowski, Robert

    2015-01-01

    The Rapid Cycle Amine (RCA) 3.0 system is currently under development by NASA, the Lyndon B. Johnson Space Center (JSC) in conjunction with United Technologies Corporation Aerospace Systems (UTAS). The RCA technology is a new carbon dioxide (CO2) and humidity removal system that has been baselined for the Advanced Extravehicular Mobility Unit (AEMU) Portable Life Support System. The evolution of the RCA development has progressed through several iterations of technology readiness levels including RCA 1.0, RCA 2.0, and RCA 3.0 test articles. The RCA is an advancement over currently technologies due to its unique regeneration capability. The RCA is capable of simultaneously removing CO2 and humidity from an influent air steam and subsequent regeneration when exposed to a vacuum source. The RCA technology uses two solid amine sorbent beds in an alternating fashion to adsorb CO2 and water (uptake mode) and desorb CO2 and water (regeneration mode) at the same time. The two beds operate in an efficient manner so that while one bed is in the uptake mode, the other is in the regeneration mode, thus continuously providing an on-service sorbent bed by which CO2 and humidity may be removed. The RCA 2.0 and 3.0 test articles were designed with a novel valve assembly which allows for switching between uptake and regeneration modes with only one moving part while minimizing gas volume losses to the vacuum source by means of an internal pressure equalization step during actuation. The RCA technology also is low power, small, and has performed extremely well in all development testing thus far. A final design was selected for the RCA 3.0, fabricated, assembled, and performance tested in 2014 with delivery to NASAJSC in January 2015. This paper will provide an overview on the RCA 3.0 system design and results of pre-delivery testing with references to the development of RCA 1.0 and RCA 2.0.

  6. A Rapid Prototyping Environment for Cooperative Advanced Driver Assistance Systems

    Directory of Open Access Journals (Sweden)

    Kay Massow

    2018-01-01

    Full Text Available Advanced Driver Assistance Systems (ADAS were strong innovation drivers in recent years, towards the enhancement of traffic safety and efficiency. Today’s ADAS adopt an autonomous approach with all instrumentation and intelligence on board of one vehicle. However, to further enhance their benefit, ADAS need to cooperate in the future, using communication technologies. The resulting combination of vehicle automation and cooperation, for instance, enables solving hazardous situations by a coordinated safety intervention on multiple vehicles at the same point in time. Since the complexity of such cooperative ADAS grows with each vehicle involved, very large parameter spaces need to be regarded during their development, which necessitate novel development approaches. In this paper, we present an environment for rapidly prototyping cooperative ADAS based on vehicle simulation. Its underlying approach is either to bring ideas for cooperative ADAS through the prototyping stage towards plausible candidates for further development or to discard them as quickly as possible. This is enabled by an iterative process of refining and assessment. We reconcile the aspects of automation and cooperation in simulation by a tradeoff between precision and scalability. Reducing precise mapping of vehicle dynamics below the limits of driving dynamics enables simulating multiple vehicles at the same time. In order to validate this precision, we also present a method to validate the vehicle dynamics in simulation against real world vehicles.

  7. Modeling system for the rapid construction in Syria

    Directory of Open Access Journals (Sweden)

    Ahmed, Sonia

    2016-06-01

    Full Text Available Prefabrication is a manufacturing process conducted at a specialized facility, in which various materials are joined to form a component part of the final installation. Prefabrication techniques have been progressively adopted in the construction industry in various countries. The demand was at its peak in the early 1970s in Eastern and Western Europe for the construction of new towns. Worldwide, the highest precast levels in 1996 were located in Denmark (43%, the Netherlands (40%, Sweden and Germany (31%. In Asia, the precast levels in Japan and Singapore were about 15% and 8%, respectively, recently, the use of prefabrication is further encouraged to increase productivity and build ability. In Syria too, the first residential project in Damascus: the establishment of 2400 housing units in the year (77-80. Except that the rate of construction pre-cast in Syria is still not exceed 2% of Building of reinforced concrete. In order to participate in the reconstruction of Syria, after the destruction and devastation caused by the war over four years, this search evaluates successful international experiences in rapid construction technique, and modeled system that could serve the current Syrian reality. Introduction of this technology as a new method in the world of construction in Syria requires a good base, relying on the availability of the necessary raw materials and nearness of work site, as well as the need to replace old technology into modern technology, and analyzing the economic, social, environmental criteria, to make the decision about the best solution. Cost and time will form the most important indicators that will be analyzed and calculated, before the final model mode, in order to be able to use this system later in Syrian construction companies.

  8. Rapid Process to Generate Beam Envelopes for Optical System Analysis

    Science.gov (United States)

    Howard, Joseph; Seals, Lenward

    2012-01-01

    The task of evaluating obstructions in the optical throughput of an optical system requires the use of two disciplines, and hence, two models: optical models for the details of optical propagation, and mechanical models for determining the actual structure that exists in the optical system. Previous analysis methods for creating beam envelopes (or cones of light) for use in this obstruction analysis were found to be cumbersome to calculate and take significant time and resources to complete. A new process was developed that takes less time to complete beam envelope analysis, is more accurate and less dependent upon manual node tracking to create the beam envelopes, and eases the burden on the mechanical CAD (computer-aided design) designers to form the beam solids. This algorithm allows rapid generation of beam envelopes for optical system obstruction analysis. Ray trace information is taken from optical design software and used to generate CAD objects that represent the boundary of the beam envelopes for detailed analysis in mechanical CAD software. Matlab is used to call ray trace data from the optical model for all fields and entrance pupil points of interest. These are chosen to be the edge of each space, so that these rays produce the bounding volume for the beam. The x and y global coordinate data is collected on the surface planes of interest, typically an image of the field and entrance pupil internal of the optical system. This x and y coordinate data is then evaluated using a convex hull algorithm, which removes any internal points, which are unnecessary to produce the bounding volume of interest. At this point, tolerances can be applied to expand the size of either the field or aperture, depending on the allocations. Once this minimum set of coordinates on the pupil and field is obtained, a new set of rays is generated between the field plane and aperture plane (or vice-versa). These rays are then evaluated at planes between the aperture and field, at a

  9. The Namibian Scoring System (NASS) version 2 rapid bio ...

    African Journals Online (AJOL)

    This paper presents a rapid bio-assessment method for assessing the ... The method uses the composition and abundance of aquatic invertebrates, which are ... Training of Namibian personnel to apply the method, as part of the National ...

  10. Model evaluation of denitrification under rapid infiltration basin systems.

    Science.gov (United States)

    Akhavan, Maryam; Imhoff, Paul T; Andres, A Scott; Finsterle, Stefan

    2013-09-01

    Rapid Infiltration Basin Systems (RIBS) are used for disposing reclaimed wastewater into soil to achieve additional treatment before it recharges groundwater. Effluent from most new sequenced batch reactor wastewater treatment plants is completely nitrified, and denitrification (DNF) is the main reaction for N removal. To characterize effects of complex surface and subsurface flow patterns caused by non-uniform flooding on DNF, a coupled overland flow-vadose zone model is implemented in the multiphase flow and reactive transport simulator TOUGHREACT. DNF is simulated in two representative soils varying the application cycle, hydraulic loading rate, wastewater quality, water table depth, and subsurface heterogeneity. Simulations using the conventional specified flux boundary condition under-predict DNF by as much as 450% in sand and 230% in loamy sand compared to predictions from the coupled overland flow-vadose zone model, indicating that simulating coupled flow is critical for predicting DNF in cases where hydraulic loading rates are not sufficient to spread the wastewater over the whole basin. Smaller ratios of wetting to drying time and larger hydraulic loading rates result in greater water saturations, more anoxic conditions, and faster water transport in the vadose zone, leading to greater DNF. These results in combination with those from different water table depths explain why reported DNF varied with soil type and water table depth in previous field investigations. Across all simulations, cumulative percent DNF varies between 2 and 49%, indicating that NO₃ removal in RIBS may vary widely depending on operational procedures and subsurface conditions. These modeling results improve understanding of DNF in RIBS and suggest operational procedures that may improve NO₃ removal. Copyright © 2013 Elsevier B.V. All rights reserved.

  11. Rapid earthquake magnitude determination for Vrancea early warning system

    International Nuclear Information System (INIS)

    Marmureanu, Alexandru

    2009-01-01

    Due to the huge amount of recorded data, an automatic procedure was developed and used to test different methods to rapidly evaluate earthquake magnitude from the first seconds of the P wave. In order to test all the algorithms involved in detection and rapid earthquake magnitude estimation, several tests were performed, in order to avoid false alarms. A special detection algorithm was developed, that is based on the classical STA/LTA algorithm and tuned for early warning purpose. A method to rapidly estimate magnitude in 4 seconds from detection of P wave in the epicenter is proposed. The method was tested on al recorded data, and the magnitude error determination is acceptable taking into account that it is computed from only 3 stations in a very short time interval. (author)

  12. Rapid Damage Assessment. Volume II. Development and Testing of Rapid Damage Assessment System.

    Science.gov (United States)

    1981-02-01

    pixels/s Camera Line Rate 732.4 lines/s Pixels per Line 1728 video 314 blank 4 line number (binary) 2 run number (BCD) 2048 total Pixel Resolution 8 bits...sists of an LSI-ll microprocessor, a VDI -200 video display processor, an FD-2 dual floppy diskette subsystem, an FT-I function key-trackball module...COMPONENT LIST FOR IMAGE PROCESSOR SYSTEM IMAGE PROCESSOR SYSTEM VIEWS I VDI -200 Display Processor Racks, Table FD-2 Dual Floppy Diskette Subsystem FT-l

  13. Development of rapid phenotypic system for the identification

    Indian Academy of Sciences (India)

    Rapid and accurate identification of bacterial pathogens is a fundamental goal of clinical microbiology. The diagnosis and surveillance of diseases is dependent, to a great extent, on laboratory services, which cannot function without effective reliable reagents and diagnostics. Despite the advancement in microbiology ...

  14. Effectiveness Analysis of a Part-Time Rapid Response System During Operation Versus Nonoperation.

    Science.gov (United States)

    Kim, Youlim; Lee, Dong Seon; Min, Hyunju; Choi, Yun Young; Lee, Eun Young; Song, Inae; Park, Jong Sun; Cho, Young-Jae; Jo, You Hwan; Yoon, Ho Il; Lee, Jae Ho; Lee, Choon-Taek; Do, Sang Hwan; Lee, Yeon Joo

    2017-06-01

    To evaluate the effect of a part-time rapid response system on the occurrence rate of cardiopulmonary arrest by comparing the times of rapid response system operation versus nonoperation. Retrospective cohort study. A 1,360-bed tertiary care hospital. Adult patients admitted to the general ward were screened. Data were collected over 36 months from rapid response system implementation (October 2012 to September 2015) and more than 45 months before rapid response system implementation (January 2009 to September 2012). None. The rapid response system operates from 7 AM to 10 PM on weekdays and from 7 AM to 12 PM on Saturdays. Primary outcomes were the difference of cardiopulmonary arrest incidence between pre-rapid response system and post-rapid response system periods and whether the rapid response system operating time affects the cardiopulmonary arrest incidence. The overall cardiopulmonary arrest incidence (per 1,000 admissions) was 1.43. Although the number of admissions per month and case-mix index were increased (3,555.18 vs 4,564.72, p times (0.82 vs 0.49/1,000 admissions; p = 0.001) but remained similar during rapid response system nonoperating times (0.77 vs 0.73/1,000 admissions; p = 0.729). The implementation of a part-time rapid response system reduced the cardiopulmonary arrest incidence based on the reduction of cardiopulmonary arrest during rapid response system operating times. Further analysis of the cost effectiveness of part-time rapid response system is needed.

  15. Consumer perceptions of the Nutrition Facts table and front-of-pack nutrition rating systems.

    Science.gov (United States)

    Emrich, Teri E; Qi, Ying; Mendoza, Julio E; Lou, Wendy; Cohen, Joanna E; L'abbé, Mary R

    2014-04-01

    Preferences for, and consumer friendliness of, front-of-pack (FOP) nutrition rating systems have not been studied in a Canadian population, and studies comparing systems that are accompanied by mandatory labelling, such as Canada's Nutrition Facts table (NFt), are lacking. The purpose of this study was to evaluate 4 FOP systems relative to the NFt with respect to consumer friendliness and their influence on perceptions of the healthiness and nutrient content of food. Canadian consumers (n = 3029) participating in an online survey were randomized to score the consumer friendliness of 1 of 5 FOP conditions with or without an NFt and to score the healthiness and nutrient content of 2 foods using the provided label(s). The mean differences in scores were evaluated with analysis of covariance (ANCOVA) controlling for age, gender, and education, with Tukey-Kramer adjustments for multiple comparisons. The NFt received the highest scores of consumer friendliness with respect to liking, helpfulness, credibility, and influence on purchase decisions (p consumers still supported the implementation of a single, standardized FOP system, with the nutrient-specific systems (a "Traffic Light" and a Nutrition Facts FOP system) being preferred and scored as more consumer friendly than the summary indicator systems. Without the NFt, consumer ratings of the healthiness and calorie and nutrient content differed by FOP system. With the NFt present, consumers rated the healthiness and calorie and nutrient content similarly, except for those who saw the Traffic Light; their ratings were influenced by the Traffic Light's colours. The introduction of a single, standard, nutrient-specific FOP system to supplement the mandatory NFt should be considered by Canadian policy makers.

  16. Global Navigation Satellite System (GNSS) Rapid Clock Product Summary from NASA CDDIS

    Data.gov (United States)

    National Aeronautics and Space Administration — This derived product set consists of Global Navigation Satellite System Rapid Clock Product Summary from the NASA Crustal Dynamics Data Information System (CDDIS)....

  17. Using Modified Fagan Inspections to Control Rapid System Development

    Science.gov (United States)

    Griesel, M. A.; Welz, L. L.

    1994-01-01

    The Jet Propulsion Laboratory (JPL) has been developing new approaches to software and system development to shorten life cycle time and reduce total life-cycle cost, while maintaining product quality. One such approach has been taken by the Just-In-Time (JIT) Materiel Acquisition System Development Project.

  18. Rapid Transient Fault Insertion in Large Digital Systems

    NARCIS (Netherlands)

    Rohani, A.; Kerkhoff, Hans G.

    This paper presents a technique for rapidtransientfault injection, regarding the CPU time, to perform simulation-based fault-injection in complex System-on-Chip Systems (SoCs). The proposed approach can be applied to complex circuits, as it is not required to modify the top-level modules of a

  19. RAPID FREEFORM SHEET METAL FORMING: TECHNOLOGY DEVELOPMENT AND SYSTEM VERIFICATION

    Energy Technology Data Exchange (ETDEWEB)

    Kiridena, Vijitha [Ford Scientific Research Lab., Dearborn, MI (United States); Verma, Ravi [Boeing Research and Technology (BR& T), Seattle, WA (United States); Gutowski, Timothy [Massachusetts Inst. of Technology (MIT), Cambridge, MA (United States); Roth, John [Pennsylvania State Univ., University Park, PA (United States)

    2018-03-31

    The objective of this project is to develop a transformational RApid Freeform sheet metal Forming Technology (RAFFT) in an industrial environment, which has the potential to increase manufacturing energy efficiency up to ten times, at a fraction of the cost of conventional technologies. The RAFFT technology is a flexible and energy-efficient process that eliminates the need for having geometry-specific forming dies. The innovation lies in the idea of using the energy resource at the local deformation area which provides greater formability, process control, and process flexibility relative to traditional methods. Double-Sided Incremental Forming (DSIF), the core technology in RAFFT, is a new concept for sheet metal forming. A blank sheet is clamped around its periphery and gradually deformed into a complex 3D freeform part by two strategically aligned stylus-type tools that follow a pre-described toolpath. The two tools, one on each side of the blank, can form a part with sharp features for both concave and convex shapes. Since deformation happens locally, the forming force at any instant is significantly decreased when compared to traditional methods. The key advantages of DSIF are its high process flexibility, high energy-efficiency, low capital investment, and the elimination of the need for massive amounts of die casting and machining. Additionally, the enhanced formability and process flexibility of DSIF can open up design spaces and result in greater weight savings.

  20. Speciation in rapidly diverging systems: lessons from Lake Malawi.

    Science.gov (United States)

    Danley, P D; Kocher, T D

    2001-05-01

    Rapid evolutionary radiations provide insight into the fundamental processes involved in species formation. Here we examine the diversification of one such group, the cichlid fishes of Lake Malawi, which have radiated from a single ancestor into more than 400 species over the past 700 000 years. The phylogenetic history of this group suggests: (i) that their divergence has proceeded in three major bursts of cladogenesis; and (ii) that different selective forces have dominated each cladogenic event. The first episode resulted in the divergence of two major lineages, the sand- and rock-dwellers, each adapted to a major benthic macrohabitat. Among the rock-dwellers, competition for trophic resources then drove a second burst of cladogenesis, which resulted in the differentiation of trophic morphology. The third episode of cladogenesis is associated with differentiation of male nuptial colouration, most likely in response to divergent sexual selection. We discuss models of speciation in relation to this observed pattern. We advocate a model, divergence with gene flow, which reconciles the disparate selective forces responsible for the diversification of this group and suggest that the nonadaptive nature of the tertiary episode has significantly contributed to the extraordinary species richness of this group.

  1. Computational System For Rapid CFD Analysis In Engineering

    Science.gov (United States)

    Barson, Steven L.; Ascoli, Edward P.; Decroix, Michelle E.; Sindir, Munir M.

    1995-01-01

    Computational system comprising modular hardware and software sub-systems developed to accelerate and facilitate use of techniques of computational fluid dynamics (CFD) in engineering environment. Addresses integration of all aspects of CFD analysis process, including definition of hardware surfaces, generation of computational grids, CFD flow solution, and postprocessing. Incorporates interfaces for integration of all hardware and software tools needed to perform complete CFD analysis. Includes tools for efficient definition of flow geometry, generation of computational grids, computation of flows on grids, and postprocessing of flow data. System accepts geometric input from any of three basic sources: computer-aided design (CAD), computer-aided engineering (CAE), or definition by user.

  2. Motion Planning for a Direct Metal Deposition Rapid Prototyping System

    Energy Technology Data Exchange (ETDEWEB)

    AMES,ARLO L.; HENSINGER,DAVID M.; KUHLMANN,JOEL L.

    1999-10-18

    A motion planning strategy was developed and implemented to generate motion control instructions from solid model data for controlling a robotically driven solid free-form fabrication process. The planning strategy was tested using a PUMA type robot arm integrated into a LENS{trademark} (Laser Engineered Net Shape) system. Previous systems relied on a series of x, y, and z stages, to provide a minimal coordinated motion control capability. This limited the complexity of geometries that could be constructed. With the coordinated motion provided by a robotic arm, the system can produce three dimensional parts by ''writing'' material onto any face of existing material. The motion planning strategy relied on solid model geometry evaluation and exploited robotic positioning flexibility to allow the construction of geometrically complex parts. The integration of the robotic manipulator into the LENS{trademark} system was tested by producing metal parts directly from CAD models.

  3. Modeling and evaluation of characteristics for on-street Rapid Transit systems

    DEFF Research Database (Denmark)

    Andersen, Jonas Lohmann Elkjær; Landex, Alex

    2012-01-01

    to obtain the main objective of introducing a Rapid Transit System. to increase the number of passengers. Variations in the system characteristics have a direct impact on ridership. However, it is difficult to predict the impact of implementing or altering the characteristics. A Rapid Transit system should...... display sufficient service already in the planning phase. That is why pre-acquired knowledge of the impact of the characteristics on the system performance is valuable. Such knowledge could provide a firm basis for planning the service and operation of a Rapid Transit system. This article focuses....... It focuses on the following characteristics for Rapid Transit systems: rail factor, travel time, headway and capacity. It evaluates how the implementation and variation of these characteristics affected the ridership of a case project. It evaluates the magnitude of the impacts for the various characteristics...

  4. Automated Loading and Unloading of the Stratasys FDM 1600 Rapid Prototyping System

    OpenAIRE

    Brockmeier, Oivind

    2000-01-01

    Rapid prototyping systems have advanced significantly with respect to material capabilities, fabrication speed, and surface quality. However, build jobs are still manually activated one at a time. The result is non-productive machine time whenever an operator is not at hand to make a job changeover. A low-cost auxiliary system, named Continuous Layered Manufacturing (CLM), has been developed to automatically load and unload the FDM 1600 rapid prototyping system (Stratasys, Inc.). The modifica...

  5. Rapid mental computation system as a tool for algorithmic thinking of elementary school students development

    OpenAIRE

    Ziatdinov, Rushan; Musa, Sajid

    2013-01-01

    In this paper, we describe the possibilities of using a rapid mental computation system in elementary education. The system consists of a number of readily memorized operations that allow one to perform arithmetic computations very quickly. These operations are actually simple algorithms which can develop or improve the algorithmic thinking of pupils. Using a rapid mental computation system allows forming the basis for the study of computer science in secondary school.

  6. Advantages of utilizing DMD based rapid manufacturing systems in mass customization applications

    Science.gov (United States)

    El-Siblani, A.

    2010-02-01

    The Use of DMD based Rapid Manufacturing Systems has proven to be very advantageous in the production of highly accurate plastic based components for use in mass customization market such as hearing aids, and dental markets. The voxelization process currently afforded with the DLP technology eliminates any layering effect associated with all existing additive Rapid Manufacturing technologies. The smooth accurate surfaces produced in an additive process utilizing DLP technology, through the voxelization approach, allow for the production of custom finished products. The implementation of DLP technology in rapid prototyping and rapid manufacturing systems allow for the usage of highly viscous photopolymer based liquid and paste composites for rapid manufacturing that could not be used in any other additive process prior to implementation of DLP technology in RP and RM systems. It also allowed for the greater throughput in production without sacrificing quality and accuracy.

  7. Mobile Complex For Rapid Diagnosis of the Technological System Elements

    Directory of Open Access Journals (Sweden)

    Gavrilin Alexey

    2016-01-01

    Full Text Available The article shows the up-to-dateness of the new informing and measuring tools and technologies development. It is reviewed the mobile complex for runtime diagnostics of technological system “machine-toolinstrument- detail”. It was found that the use of the complex allows to identify the frequency area in which the appearance of resonance of the technological system elements is possible, and thus to draw a conclusion on the technical state of the diagnosed object. It is concluded that there is the prospects for the use of the above mentioned mobile complex for vibration diagnostics.

  8. The rapid atmospheric monitoring system of the Pierre Auger Observatory

    Czech Academy of Sciences Publication Activity Database

    Abreu, P.; Aglietta, M.; Ahlers, M.; Boháčová, Martina; Chudoba, Jiří; Ebr, Jan; Mandát, Dušan; Nečesal, Petr; Nožka, Libor; Palatka, Miroslav; Pech, Miroslav; Prouza, Michael; Řídký, Jan; Schovancová, Jaroslava; Schovánek, Petr; Šmída, Radomír; Trávníček, Petr; Vícha, Jakub

    2012-01-01

    Roč. 7, č. 9 (2012), s. 1-40 ISSN 1748-0221 R&D Projects: GA TA ČR TA01010517; GA MŠk(CZ) MEB111003; GA AV ČR KJB100100904; GA MŠk LA08015; GA MŠk(CZ) LA08016 Institutional research plan: CEZ:AV0Z10100502; CEZ:AV0Z10100522 Keywords : large detector systems for particle and astroparticle physics * real-time monitoring * control and monitor systems online Subject RIV: BN - Astronomy, Celestial Mechanics, Astrophysics Impact factor: 1.869, year: 2011

  9. On complex adaptive systems and terrorism [rapid communication

    Science.gov (United States)

    Ahmed, E.; Elgazzar, A. S.; Hegazi, A. S.

    2005-03-01

    Complex adaptive systems (CAS) are ubiquitous in nature. They are basic in social sciences. An overview of CAS is given with emphasize on the occurrence of bad side effects to seemingly “wise” decisions. Hence application to terrorism is given. Some conclusions on how to deal with this phenomena are proposed.

  10. Rapid Prototyping of Social Group Dynamics in Multiagent Systems

    DEFF Research Database (Denmark)

    Rehm, Matthias; Endrass, Birgit

    2009-01-01

    In this article we present an engineering approach for the integration of social group dynamics in the behavior modeling of multiagent systems. To this end, a toolbox was created that brings together several theories from the social sciences, each focusing on different aspects of group dynamics. ...

  11. Automatic performance estimation of conceptual temperature control system design for rapid development of real system

    International Nuclear Information System (INIS)

    Jang, Yu Jin

    2013-01-01

    This paper presents an automatic performance estimation scheme of conceptual temperature control system with multi-heater configuration prior to constructing the physical system for achieving rapid validation of the conceptual design. An appropriate low-order discrete-time model, which will be used in the controller design, is constructed after determining several basic factors including the geometric shape of controlled object and heaters, material properties, heater arrangement, etc. The proposed temperature controller, which adopts the multivariable GPC (generalized predictive control) scheme with scale factors, is then constructed automatically based on the above model. The performance of the conceptual temperature control system is evaluated by using a FEM (finite element method) simulation combined with the controller.

  12. Automatic performance estimation of conceptual temperature control system design for rapid development of real system

    Energy Technology Data Exchange (ETDEWEB)

    Jang, Yu Jin [Dongguk University, GyeongJu (Korea, Republic of)

    2013-07-15

    This paper presents an automatic performance estimation scheme of conceptual temperature control system with multi-heater configuration prior to constructing the physical system for achieving rapid validation of the conceptual design. An appropriate low-order discrete-time model, which will be used in the controller design, is constructed after determining several basic factors including the geometric shape of controlled object and heaters, material properties, heater arrangement, etc. The proposed temperature controller, which adopts the multivariable GPC (generalized predictive control) scheme with scale factors, is then constructed automatically based on the above model. The performance of the conceptual temperature control system is evaluated by using a FEM (finite element method) simulation combined with the controller.

  13. Rapid Prototyping of Standard Compliant Visible Light Communications System

    OpenAIRE

    Gavrincea, Ciprian; Baranda, Jorge; Henarejos, Pol

    2014-01-01

    This article describes the implementation of a prototype visible light communications system based on the IEEE 802.15.7 standard using low-cost commercial off-the-shelf analog devices. The aim of this article is to show that this standard provides a framework that could promote the introduction of applications into the market. Thus, these specifications could be further developed, reducing the gap between the industry and research communities. The implemented prototype makes use of software d...

  14. Rapid Auditory System Adaptation Using a Virtual Auditory Environment

    Directory of Open Access Journals (Sweden)

    Gaëtan Parseihian

    2011-10-01

    Full Text Available Various studies have highlighted plasticity of the auditory system from visual stimuli, limiting the trained field of perception. The aim of the present study is to investigate auditory system adaptation using an audio-kinesthetic platform. Participants were placed in a Virtual Auditory Environment allowing the association of the physical position of a virtual sound source with an alternate set of acoustic spectral cues or Head-Related Transfer Function (HRTF through the use of a tracked ball manipulated by the subject. This set-up has the advantage to be not being limited to the visual field while also offering a natural perception-action coupling through the constant awareness of one's hand position. Adaptation process to non-individualized HRTF was realized through a spatial search game application. A total of 25 subjects participated, consisting of subjects presented with modified cues using non-individualized HRTF and a control group using individual measured HRTFs to account for any learning effect due to the game itself. The training game lasted 12 minutes and was repeated over 3 consecutive days. Adaptation effects were measured with repeated localization tests. Results showed a significant performance improvement for vertical localization and a significant reduction in the front/back confusion rate after 3 sessions.

  15. Rapid Onboard Trajectory Design for Autonomous Spacecraft in Multibody Systems

    Science.gov (United States)

    Trumbauer, Eric Michael

    This research develops automated, on-board trajectory planning algorithms in order to support current and new mission concepts. These include orbiter missions to Phobos or Deimos, Outer Planet Moon orbiters, and robotic and crewed missions to small bodies. The challenges stem from the limited on-board computing resources which restrict full trajectory optimization with guaranteed convergence in complex dynamical environments. The approach taken consists of leveraging pre-mission computations to create a large database of pre-computed orbits and arcs. Such a database is used to generate a discrete representation of the dynamics in the form of a directed graph, which acts to index these arcs. This allows the use of graph search algorithms on-board in order to provide good approximate solutions to the path planning problem. Coupled with robust differential correction and optimization techniques, this enables the determination of an efficient path between any boundary conditions with very little time and computing effort. Furthermore, the optimization methods developed here based on sequential convex programming are shown to have provable convergence properties, as well as generating feasible major iterates in case of a system interrupt -- a key requirement for on-board application. The outcome of this project is thus the development of an algorithmic framework which allows the deployment of this approach in a variety of specific mission contexts. Test cases related to missions of interest to NASA and JPL such as a Phobos orbiter and a Near Earth Asteroid interceptor are demonstrated, including the results of an implementation on the RAD750 flight processor. This method fills a gap in the toolbox being developed to create fully autonomous space exploration systems.

  16. Design Review Closure Report for the SY-101 Rapid Transfer System

    International Nuclear Information System (INIS)

    POWELL, W.J.

    1999-01-01

    The purpose of this report, is to document closure of design review open items, resulting from design reviews conducted for the SY-101 Respond And Pump In Days (RAPID) Transfer System. Results of the various design reviews were documented in the Design Review Report for The SY-101 Rapid Mitigation System, HNF-4519. In that report, twenty-three open items were identified. In this report the 23 items are reviewed and statused

  17. Design Review Closure Report for the SY-101 Rapid Transfer System

    Energy Technology Data Exchange (ETDEWEB)

    POWELL, W.J.

    1999-11-29

    The purpose of this report, is to document closure of design review open items, resulting from design reviews conducted for the SY-101 Respond And Pump In Days (RAPID) Transfer System. Results of the various design reviews were documented in the Design Review Report for The SY-101 Rapid Mitigation System, HNF-4519. In that report, twenty-three open items were identified. In this report the 23 items are reviewed and statused.

  18. Prerouted FPGA Cores for Rapid System Construction in a Dynamic Reconfigurable System

    Directory of Open Access Journals (Sweden)

    Oliver TimothyF

    2007-01-01

    Full Text Available A method of constructing prerouted FPGA cores, which lays the foundations for a rapid system construction framework for dynamically reconfigurable computing systems, is presented. Two major challenges are considered: how to manage the wires crossing a core's borders; and how to maintain an acceptable level of flexibility for system construction with only a minimum of overhead. In order to maintain FPGA computing performance, it is crucial to thoroughly analyze the issues at the lowest level of device detail in order to ensure that computing circuit encapsulation is as efficient as possible. We present the first methodology that allows a core to scale its interface bandwidth to the maximum available in a routing channel. Cores can be constructed independently from the rest of the system using a framework that is independent of the method used to place and route primitive components within the core. We use an abstract FPGA model and CAD tools that mirror those used in industry. An academic design flow has been modified to include a wire policy and an interface constraints framework that tightly constrains the use of the wires that cross a core's boundaries. Using this tool set we investigate the effect of prerouting on overall system optimality. Abutting cores are instantly connected by colocation of interface wires. Eliminating run-time routing drastically reduces the time taken to construct a system using a set of cores.

  19. Long-term culture change related to rapid response system implementation.

    Science.gov (United States)

    Stevens, Jennifer; Johansson, Anna; Lennes, Inga; Hsu, Douglas; Tess, Anjala; Howell, Michael

    2014-12-01

    Increasing attention to patient safety in training hospitals may come at the expense of trainee autonomy and professional growth. This study sought to examine changes in medical trainees' self-reported behaviour after the institution-wide implementation of a rapid response system. We conducted a two-point cross-sectional survey of medical trainees in 2006, during the implementation of a rapid response system, and in 2010, in a single academic medical centre. A novel instrument was used to measure trainee likelihood of calling for supervisory assistance, perception of autonomy, and comfort in managing decompensating patients. Non-parametric tests to assess for change were used and year of training was evaluated as an effect modifier. Response rates were 38% in 2006 and 70% in 2010. After 5 years of the full implementation of the rapid response system, residents were significantly more likely to report calling their attending physicians for assistance (rising from 40% to 65% of relevant situations; p autonomy at 5 years after the implementation of the rapid response system. These changes were mirrored in the actual use of the rapid response system, which increased by 41% during the 5-year period after adjustment for patient volume (p < 0.0001). A primary team-focused implementation of a rapid response system was associated with durable changes in resident physicians' reported behaviour, including increased comfort with involving more experienced physicians and managing unstable patients. © 2014 John Wiley & Sons Ltd.

  20. System for rapid detection of antibiotic resistance of airborne pathogens

    Science.gov (United States)

    Fortin, M.; Noiseux, I.; Mouslinkina, L.; Vernon, M. L.; Laflamme, C.; Filion, G.; Duchaine, C.; Ho, J.

    2009-05-01

    This project uses function-based detection via a fundamental understanding of the genetic markers of AR to distinguish harmful organisms from innocuous ones. This approach circumvents complex analyses to unravel the taxonomic details of 1399 pathogen species, enormously simplifying detection requirements. Laval Hospital's fast permeabilization strategy enables AR revelation in <1hr. Packaging the AR protocols in liquid-processing cartridges and coupling these to our in-house miniature fiber optic flow cell (FOFC) provides first responders with timely information on-site. INO's FOFC platform consists of a specialty optical fiber through which a hole is transversally bored by laser micromachining. The analyte solution is injected into the hole of the fiber and the particles are detected and counted. The advantage with respect to classic free space FC is that alignment occurs in the fabrication process only and complex excitation and collection optics are replaced by optical fibers. Moreover, we use a sheathless configuration which has the advantage of increase the portability of the system, to reduce excess biohazard material and the need for weekly maintenance. In this paper we present the principle of our FOFC along with a, demonstration of the basic capability of the platform for detection of bacillus cereus spores using permeabilized staining.

  1. Rapid Discrimination Among Putative Mechanistic Models of Biochemical Systems.

    Science.gov (United States)

    Lomnitz, Jason G; Savageau, Michael A

    2016-08-31

    An overarching goal in molecular biology is to gain an understanding of the mechanistic basis underlying biochemical systems. Success is critical if we are to predict effectively the outcome of drug treatments and the development of abnormal phenotypes. However, data from most experimental studies is typically noisy and sparse. This allows multiple potential mechanisms to account for experimental observations, and often devising experiments to test each is not feasible. Here, we introduce a novel strategy that discriminates among putative models based on their repertoire of qualitatively distinct phenotypes, without relying on knowledge of specific values for rate constants and binding constants. As an illustration, we apply this strategy to two synthetic gene circuits exhibiting anomalous behaviors. Our results show that the conventional models, based on their well-characterized components, cannot account for the experimental observations. We examine a total of 40 alternative hypotheses and show that only 5 have the potential to reproduce the experimental data, and one can do so with biologically relevant parameter values.

  2. Luciferase-Zinc-Finger System for the Rapid Detection of Pathogenic Bacteria.

    Science.gov (United States)

    Shi, Chu; Xu, Qing; Ge, Yue; Jiang, Ling; Huang, He

    2017-08-09

    Rapid and reliable detection of pathogenic bacteria is crucial for food safety control. Here, we present a novel luciferase-zinc finger system for the detection of pathogens that offers rapid and specific profiling. The system, which uses a zinc-finger protein domain to probe zinc finger recognition sites, was designed to bind the amplified conserved regions of 16S rDNA, and the obtained products were detected using a modified luciferase. The luciferase-zinc finger system not only maintained luciferase activity but also allowed the specific detection of different bacterial species, with a sensitivity as low as 10 copies and a linear range from 10 to 10 4 copies per microliter of the specific PCR product. Moreover, the system is robust and rapid, enabling the simultaneous detection of 6 species of bacteria in artificially contaminated samples with excellent accuracy. Thus, we envision that our luciferase-zinc finger system will have far-reaching applications.

  3. Successfulness of bus rapid transit systems in Asia. Ex-post evaluation

    NARCIS (Netherlands)

    Kogdenko, Nadja

    2010-01-01

    SUMMARY Bus Rapid Transit (BRT) can be defined as “a bus-based mass transit system that delivers fast, comfortable, and cost-effective urban mobility”. It offers the opportunity to create a high-quality mass transit system at affordable costs, which is p

  4. Area law for fixed points of rapidly mixing dissipative quantum systems

    Energy Technology Data Exchange (ETDEWEB)

    Brandão, Fernando G. S. L. [Quantum Architectures and Computation Group, Microsoft Research, Redmond, Washington 98052 (United States); Department of Computer Science, University College London, Gower Street, London WC1E 6BT (United Kingdom); Cubitt, Toby S. [Department of Computer Science, University College London, Gower Street, London WC1E 6BT (United Kingdom); DAMTP, University of Cambridge, Cambridge (United Kingdom); Lucia, Angelo, E-mail: anlucia@ucm.es [Departamento de Análisis Matemático, Universidad Complutense de Madrid, Madrid (Spain); Michalakis, Spyridon [Institute for Quantum Information and Matter, Caltech, California 91125 (United States); Perez-Garcia, David [Departamento de Análisis Matemático, Universidad Complutense de Madrid, Madrid (Spain); IMI, Universidad Complutense de Madrid, Madrid (Spain); ICMAT, C/Nicolás Cabrera, Campus de Cantoblanco, 28049 Madrid (Spain)

    2015-10-15

    We prove an area law with a logarithmic correction for the mutual information for fixed points of local dissipative quantum system satisfying a rapid mixing condition, under either of the following assumptions: the fixed point is pure or the system is frustration free.

  5. Rapid Object Detection Systems, Utilising Deep Learning and Unmanned Aerial Systems (uas) for Civil Engineering Applications

    Science.gov (United States)

    Griffiths, D.; Boehm, J.

    2018-05-01

    With deep learning approaches now out-performing traditional image processing techniques for image understanding, this paper accesses the potential of rapid generation of Convolutional Neural Networks (CNNs) for applied engineering purposes. Three CNNs are trained on 275 UAS-derived and freely available online images for object detection of 3m2 segments of railway track. These includes two models based on the Faster RCNN object detection algorithm (Resnet and Incpetion-Resnet) as well as the novel onestage Focal Loss network architecture (Retinanet). Model performance was assessed with respect to three accuracy metrics. The first two consisted of Intersection over Union (IoU) with thresholds 0.5 and 0.1. The last assesses accuracy based on the proportion of track covered by object detection proposals against total track length. In under six hours of training (and two hours of manual labelling) the models detected 91.3 %, 83.1 % and 75.6 % of track in the 500 test images acquired from the UAS survey Retinanet, Resnet and Inception-Resnet respectively. We then discuss the potential for such applications of such systems within the engineering field for a range of scenarios.

  6. Applications and control of air conditioning systems using rapid cycling to modulate capacity

    Energy Technology Data Exchange (ETDEWEB)

    Poort, M.J.; Bullard, C.W. [Department of Mechanical and Industrial Engineering, Air Conditioning and Refrigeration Center, University of Illinois, 1206 W. Green St., Urbana, IL 61801 (United States)

    2006-08-15

    Rapid cycling the compressor of an air conditioning or refrigeration system can be used to modulate capacity, thus offering an alternative to a variable speed compressor. This paper explores design tradeoffs to optimize rapid cycling performance based on experimental results using two different evaporators and changing other components of an air conditioning system. Rapid cycling has inherent compressor lift penalties associated with larger mass flow rates, which need to be minimized. Preventing dryout (superheating) in the evaporator during the off cycle, a major penalty as cycles are lengthened, is also important. Evaporator dryout is minimized by increasing the refrigerant side area and reducing off cycle drainage. Combining a flash gas bypass with a suction line heat exchanger was found to maximize performance during the off cycle while allowing increased cycle lengths without incurring major penalties. (author)

  7. Design of rapid prototype of UAV line-of-sight stabilized control system

    Science.gov (United States)

    Huang, Gang; Zhao, Liting; Li, Yinlong; Yu, Fei; Lin, Zhe

    2018-01-01

    The line-of-sight (LOS) stable platform is the most important technology of UAV (unmanned aerial vehicle), which can reduce the effect to imaging quality from vibration and maneuvering of the aircraft. According to the requirement of LOS stability system (inertial and optical-mechanical combined method) and UAV's structure, a rapid prototype is designed using based on industrial computer using Peripheral Component Interconnect (PCI) and Windows RTX to exchange information. The paper shows the control structure, and circuit system including the inertial stability control circuit with gyro and voice coil motor driven circuit, the optical-mechanical stability control circuit with fast-steering-mirror (FSM) driven circuit and image-deviation-obtained system, outer frame rotary follower, and information-exchange system on PC. Test results show the stability accuracy reaches 5μrad, and prove the effectiveness of the combined line-of-sight stabilization control system, and the real-time rapid prototype runs stable.

  8. [Introduction and some problems of the rapid time series laboratory reporting system].

    Science.gov (United States)

    Kanao, M; Yamashita, K; Kuwajima, M

    1999-09-01

    We introduced an on-line system of biochemical, hematological, serological, urinary, bacteriological, and emergency examinations and associated office work using a client server system NEC PC-LACS based on a system consisting of concentration of outpatient blood collection, concentration of outpatient reception, and outpatient examination by reservation. Using this on-line system, results of 71 items in chemical serological, hematological, and urinary examinations are rapidly reported within 1 hour. Since the ordering system at our hospital has not been completed yet, we constructed a rapid time series reporting system in which time series data obtained on 5 serial occasions are printed on 2 sheets of A4 paper at the time of the final report. In each consultation room of the medical outpatient clinic, at the neuromedical outpatient clinic, and at the kidney center where examinations are frequently performed, terminal equipment and a printer for inquiry were established for real-time output of time series reports. Results are reported by FAX to the other outpatient clinics and wards, and subsequently, time series reports are output at the clinical laboratory department. This system allowed rapid examination, especially preconsultation examination. This system was also useful for reducing office work and effectively utilize examination data.

  9. A predator-2 prey fast-slow dynamical system for rapid predator evolution

    DEFF Research Database (Denmark)

    Piltz, Sofia Helena; Veerman, Frits; Maini, Philip K.

    2017-01-01

    We consider adaptive change of diet of a predator population that switches its feeding between two prey populations. We develop a novel 1 fast-3 slow dynamical system to describe the dynamics of the three populations amidst continuous but rapid evolution of the predator's diet choice. The two ext...

  10. A parylene-based dual channel microelectrophoresis system for rapid mutation detection via heteroduplex analysis

    NARCIS (Netherlands)

    Sukas, S.; Erson, Ayse Elif; Sert, Cuneyt; Kulah, Haluk

    2008-01-01

    A new dual channel micro-electrophoresis system for rapid mutation detection based on heteroduplex analysis was designed and implemented. Mutation detection was successfully achieved in a total separation length of 250 μm in less than 3 min for a 590 bp DNA sample harboring a 3 bp mutation causing

  11. Advances in developing rapid, reliable and portable detection systems for alcohol.

    Science.gov (United States)

    Thungon, Phurpa Dema; Kakoti, Ankana; Ngashangva, Lightson; Goswami, Pranab

    2017-11-15

    Development of portable, reliable, sensitive, simple, and inexpensive detection system for alcohol has been an instinctive demand not only in traditional brewing, pharmaceutical, food and clinical industries but also in rapidly growing alcohol based fuel industries. Highly sensitive, selective, and reliable alcohol detections are currently amenable typically through the sophisticated instrument based analyses confined mostly to the state-of-art analytical laboratory facilities. With the growing demand of rapid and reliable alcohol detection systems, an all-round attempt has been made over the past decade encompassing various disciplines from basic and engineering sciences. Of late, the research for developing small-scale portable alcohol detection system has been accelerated with the advent of emerging miniaturization techniques, advanced materials and sensing platforms such as lab-on-chip, lab-on-CD, lab-on-paper etc. With these new inter-disciplinary approaches along with the support from the parallel knowledge growth on rapid detection systems being pursued for various targets, the progress on translating the proof-of-concepts to commercially viable and environment friendly portable alcohol detection systems is gaining pace. Here, we summarize the progress made over the years on the alcohol detection systems, with a focus on recent advancement towards developing portable, simple and efficient alcohol sensors. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Rapid response of a hydrologic system to volcanic activity: Masaya volcano, Nicaragua

    Science.gov (United States)

    Pearson, S.C.P.; Connor, C.B.; Sanford, W.E.

    2008-01-01

    Hydrologic systems change in response to volcanic activity, and in turn may be sensitive indicators of volcanic activity. Here we investigate the coupled nature of magmatic and hydrologic systems using continuous multichannel time series of soil temperature collected on the flanks of Masaya volcano, Nicaragua, one of the most active volcanoes in Central America. The soil temperatures were measured in a low-temperature fumarole field located 3.5 km down the flanks of the volcano. Analysis of these time series reveals that they respond extremely rapidly, on a time scale of minutes, to changes in volcanic activity also manifested at the summit vent. These rapid temperature changes are caused by increased flow of water vapor through flank fumaroles during volcanism. The soil temperature response, ~5 °C, is repetitive and complex, with as many as 13 pulses during a single volcanic episode. Analysis of the frequency spectrum of these temperature time series shows that these anomalies are characterized by broad frequency content during volcanic activity. They are thus easily distinguished from seasonal trends, diurnal variations, or individual rainfall events, which triggered rapid transient increases in temperature during 5% of events. We suggest that the mechanism responsible for the distinctive temperature signals is rapid change in pore pressure in response to magmatism, a response that can be enhanced by meteoric water infiltration. Monitoring of distal fumaroles can therefore provide insight into coupled volcanic-hydrologic-meteorologic systems, and has potential as an inexpensive monitoring tool.

  13. Validation of a Rapid Bacteria Endospore Enumeration System for Planetary Protection Application

    Science.gov (United States)

    Chen, Fei; Kern, Roger; Kazarians, Gayane; Venkateswaran, Kasthuri

    NASA monitors spacecraft surfaces to assure that the presence of bacterial endospores meets strict criteria at launch, to minimize the risk of inadvertent contamination of the surface of Mars. Currently, the only approved method for enumerating the spores is a culture based assay that requires three days to produce results. In order to meet the demanding schedules of spacecraft assembly, a more rapid spore detection assay is being considered as an alternate method to the NASA standard culture-based assay. The Millipore Rapid Microbiology Detection System (RMDS) has been used successfully for rapid bioburden enumeration in the pharmaceutical and food industries. The RMDS is rapid and simple, shows high sensitivity (to 1 colony forming unit [CFU]/sample), and correlates well with traditional culture-based methods. It combines membrane filtration, adenosine triphosphate (ATP) bioluminescence chemistry, and image analysis based on photon detection with a Charge Coupled Device (CCD) camera. In this study, we have optimized the assay conditions and evaluated the use of the RMDS as a rapid spore detection tool for NASA applications. In order to select for spores, the samples were subjected to a heat shock step before proceeding with the RMDS incubation protocol. Seven species of Bacillus (nine strains) that have been repeatedly isolated from clean room environments were assayed. All strains were detected by the RMDS in 5 hours and these assay times were repeatedly demonstrated along with low image background noise. Validation experiments to compare the Rapid Sore Assay (RSA) and NASA standard assay (NSA) were also performed. The evaluation criteria were modeled after the FDA Guideline of Process Validation, and Analytical Test Methods. This body of research demonstrates that the Rapid Spore Assay (RSA) is quick, and of equivalent sensitivity to the NASA standard assay, potentially reducing the assay time for bacterial endospores from over 72 hours to less than 8 hours

  14. Early warning systems and rapid response to the deteriorating patient in hospital: A realist evaluation.

    Science.gov (United States)

    McGaughey, Jennifer; O'Halloran, Peter; Porter, Sam; Trinder, John; Blackwood, Bronagh

    2017-12-01

    To test the Rapid Response Systems programme theory against actual practice components of the Rapid Response Systems implemented to identify those contexts and mechanisms which have an impact on the successful achievement of desired outcomes in practice. Rapid Response Systems allow deteriorating patients to be recognized using Early Warning Systems, referred early via escalation protocols and managed at the bedside by competent staff. Realist evaluation. The research design was an embedded multiple case study approach of four wards in two hospitals in Northern Ireland which followed the principles of Realist Evaluation. We used various mixed methods including individual and focus group interviews, observation of nursing practice between June-November 2010 and document analysis of Early Warning Systems audit data between May-October 2010 and hospital acute care training records over 4.5 years from 2003-2008. Data were analysed using NiVivo8 and SPPS. A cross-case analysis highlighted similar patterns of factors which enabled or constrained successful recognition, referral and response to deteriorating patients in practice. Key enabling factors were the use of clinical judgement by experienced nurses and the empowerment of nurses as a result of organizational change associated with implementation of Early Warning System protocols. Key constraining factors were low staffing and inappropriate skill mix levels, rigid implementation of protocols and culturally embedded suboptimal communication processes. Successful implementation of Rapid Response Systems was dependent on adopting organizational and cultural changes that facilitated staff empowerment, flexible implementation of protocols and ongoing experiential learning. © 2017 John Wiley & Sons Ltd.

  15. Computer-controlled system for rapid soil analysis of 226Ra

    International Nuclear Information System (INIS)

    Doane, R.W.; Berven, B.A.; Blair, M.S.

    1984-01-01

    A computer-controlled multichannel analysis system has been developed by the Radiological Survey Activities Group at Oak Ridge National Laboratory (ORNL) for the Department of Energy (DOE) in support of the DOE's remedial action programs. The purpose of this system is to provide a rapid estimate of the 226 Ra concentration in soil samples using a 6 x 9-in. NaI(Tl) crystal containing a 3.25-in. deep by 3.5-in. diameter well. This gamma detection system is controlled by a mini-computer with a dual floppy disk storage medium. A two-chip interface was also designed at ORNL which handles all control signals generated from the computer keyboard. These computer-generated control signals are processed in machine language for rapid data transfer and BASIC language is used for data processing

  16. Rapid antibiotic efficacy screening with aluminum oxide nanoporous membrane filter-chip and optical detection system.

    Science.gov (United States)

    Tsou, Pei-Hsiang; Sreenivasappa, Harini; Hong, Sungmin; Yasuike, Masayuki; Miyamoto, Hiroshi; Nakano, Keiyo; Misawa, Takeyuki; Kameoka, Jun

    2010-09-15

    We have developed a filter-chip and optical detection system for rapid antibiotic efficacy screening. The filter-chip consisted of a 1-mL reservoir and an anodic aluminum oxide (AAO) nanoporous membrane. Sample solution with liquid growth media, bacteria, and antibiotics was incubated in the reservoir for a specific period of time. The number of live bacteria on the surface of membrane was counted after the incubation with antibiotics and filtration. Using this biosensing system, we have demonstrated a 1-h antibiotic screening for patients' clinical samples, significantly faster than the conventional antibiotic susceptibility tests that typically take more than 24h. This rapid screening nature makes the filter-chip and detection system ideal for tailoring antibiotic treatment to individual patients by reducing the microbial antibiotic resistance, and improving the survival rate for patients suffering from postoperative infections. Published by Elsevier B.V.

  17. Knowledge acquisition and rapid protyping of an expert system: Dealing with real world problems

    Science.gov (United States)

    Bailey, Patrick A.; Doehr, Brett B.

    1988-01-01

    The knowledge engineering and rapid prototyping phases of an expert system that does fault handling for a Solid Amine, Water Desorbed CO2 removal assembly for the Environmental Control and Life Support System for space based platforms are addressed. The knowledge acquisition phase for this project was interesting because it could not follow the textbook examples. As a result of this, a variety of methods were used during the knowledge acquisition task. The use of rapid prototyping and the need for a flexible prototype suggested certain types of knowledge representation. By combining various techniques, a representative subset of faults and a method for handling those faults was achieved. The experiences should prove useful for developing future fault handling expert systems under similar constraints.

  18. Snake venoms are integrated systems, but abundant venom proteins evolve more rapidly.

    Science.gov (United States)

    Aird, Steven D; Aggarwal, Shikha; Villar-Briones, Alejandro; Tin, Mandy Man-Ying; Terada, Kouki; Mikheyev, Alexander S

    2015-08-28

    While many studies have shown that extracellular proteins evolve rapidly, how selection acts on them remains poorly understood. We used snake venoms to understand the interaction between ecology, expression level, and evolutionary rate in secreted protein systems. Venomous snakes employ well-integrated systems of proteins and organic constituents to immobilize prey. Venoms are generally optimized to subdue preferred prey more effectively than non-prey, and many venom protein families manifest positive selection and rapid gene family diversification. Although previous studies have illuminated how individual venom protein families evolve, how selection acts on venoms as integrated systems, is unknown. Using next-generation transcriptome sequencing and mass spectrometry, we examined microevolution in two pitvipers, allopatrically separated for at least 1.6 million years, and their hybrids. Transcriptomes of parental species had generally similar compositions in regard to protein families, but for a given protein family, the homologs present and concentrations thereof sometimes differed dramatically. For instance, a phospholipase A2 transcript comprising 73.4 % of the Protobothrops elegans transcriptome, was barely present in the P. flavoviridis transcriptome (king cobra genome, suggesting that rapid evolution of abundant proteins may be generally true for snake venoms. Looking more broadly at Protobothrops, we show that rapid evolution of the most abundant components is due to positive selection, suggesting an interplay between abundance and adaptation. Given log-scale differences in toxin abundance, which are likely correlated with biosynthetic costs, we hypothesize that as a result of natural selection, snakes optimize return on energetic investment by producing more of venom proteins that increase their fitness. Natural selection then acts on the additive genetic variance of these components, in proportion to their contributions to overall fitness. Adaptive

  19. A nationwide web-based automated system for early outbreak detection and rapid response in China

    Directory of Open Access Journals (Sweden)

    Yilan Liao

    2011-03-01

    Full Text Available Timely reporting, effective analyses and rapid distribution of surveillance data can assist in detecting the aberration of disease occurrence and further facilitate a timely response. In China, a new nationwide web-based automated system for outbreak detection and rapid response was developed in 2008. The China Infectious Disease Automated-alert and Response System (CIDARS was developed by the Chinese Center for Disease Control and Prevention based on the surveillance data from the existing electronic National Notifiable Infectious Diseases Reporting Information System (NIDRIS started in 2004. NIDRIS greatly improved the timeliness and completeness of data reporting with real time reporting information via the Internet. CIDARS further facilitates the data analysis, aberration detection, signal dissemination, signal response and information communication needed by public health departments across the country. In CIDARS, three aberration detection methods are used to detect the unusual occurrence of 28 notifiable infectious diseases at the county level and to transmit that information either in real-time or on a daily basis. The Internet, computers and mobile phones are used to accomplish rapid signal generation and dissemination, timely reporting and reviewing of the signal response results. CIDARS has been used nationwide since 2008; all Centers for Disease Control and Prevention (CDC in China at the county, prefecture, provincial and national levels are involved in the system. It assists with early outbreak detection at the local level and prompts reporting of unusual disease occurrences or potential outbreaks to CDCs throughout the country.

  20. Rapid transfer of short-lived radioisotopes via a 2. 4 km rabbit system

    Energy Technology Data Exchange (ETDEWEB)

    Burgerjon, J J; Gelbart, Z; Lau, V; Lehnart, D; Lenz, J; Pate, B D; Ruth, T J; Sprenger, H P; van Oers, N S.C.

    1984-09-01

    A 2.4 km long pipeline between a cyclotron and a hospital is used for the rapid transfer of short-lived radiopharmaceuticals. The vials containing the pharmaceuticals are placed inside capsules (rabbits) that are blown through a tube by means of compressed air. Travel times as short as 2 min are achieved, which makes the system suitable for the transfer of /sup 15/O, which has a 2 min half-life. The construction and test results of the system are described along with a computer model, developed to explain some properties of the system. 7 references, 15 figures, 2 tables.

  1. Knowledge bases, clinical decision support systems, and rapid learning in oncology.

    Science.gov (United States)

    Yu, Peter Paul

    2015-03-01

    One of the most important benefits of health information technology is to assist the cognitive process of the human mind in the face of vast amounts of health data, limited time for decision making, and the complexity of the patient with cancer. Clinical decision support tools are frequently cited as a technologic solution to this problem, but to date useful clinical decision support systems (CDSS) have been limited in utility and implementation. This article describes three unique sources of health data that underlie fundamentally different types of knowledge bases which feed into CDSS. CDSS themselves comprise a variety of models which are discussed. The relationship of knowledge bases and CDSS to rapid learning health systems design is critical as CDSS are essential drivers of rapid learning in clinical care. Copyright © 2015 by American Society of Clinical Oncology.

  2. A method of rapidly evaluating image quality of NED optical system

    Science.gov (United States)

    Sun, Qi; Qiu, Chuankai; Yang, Huan

    2014-11-01

    In recent years, with the development of technology of micro-display, advanced optics and the software and hardware, near-to-eye display ( NED) optical system will have a wide range of potential applications in the fields of amusement and virtual reality. However, research on the evaluating image quality of this kind optical system is comparatively lagging behind. Although now there are some methods and equipment for evaluation, they can't be applied in commercial production because of their complex operation and inaccuracy. In this paper, an academic method is proposed and a Rapid Evaluation System (RES) is designed to evaluate the image of optical system rapidly and exactly. Firstly, a set of parameters that eyes are sensitive to and also express the quality of system should be extracted and quantized to be criterion, so the evaluation standards can be established. Then, some parameters can be detected by RES consisted of micro-display, CCD camera and computer and so on. By process of scaling, the measuring results of the RES are exact and creditable, relationship between object measurement, subjective evaluation and the RES will be established. After that, image quality of optical system can be evaluated just by detecting parameters of that. The RES is simple and the results of evaluation are exact and keeping with human vision. So the method can be used not only for optimizing design of optical system, but also for evaluation in commercial production.

  3. Numerical and experimental flow analysis in centifluidic systems for rapid allergy screening tests

    Directory of Open Access Journals (Sweden)

    Dethloff Manuel

    2015-09-01

    Full Text Available For the development of the automated processing of a membrane-based rapid allergy test, the flow characteristics in one part of the test, the reagents module, are analysed. This module consists of a multichannel system with several inputs and one output. A return flow from one input channel into another should be avoided. A valveless module with pointed channels at an angle of 12° is analysed with numerical and experimental methods with regard to the flow characteristics.

  4. Present status and future development of the European Community rapid information system

    International Nuclear Information System (INIS)

    Fraser, G.

    1990-01-01

    Following the Chernobyl reactor accident it was rapidly appreciated that, in addition to upgrading national radiological monitoring systems, action was required to facilitate international communication of the results obtained. The first such system was established by the Vienna Convention, drawn up under the auspices of the IAEA, which came into force in September, 1986. Subsequently the EC Council of Ministers decided in December, 1987, to set up a Community system which in many ways parallels that established by the Convention but differs significantly in certain aspects concerning its legal basis, initiation criteria, data provisions and communications requirements. The present paper describes the present status of the Community system and foreseeable future developments. It is a matter of policy that, to avoid unnecessary complications, this system should be, to the maximum extent practicable, fully compatible with that established by the Convention. Where appropriate, therefore, reference is also made to the latter system

  5. Single-Trial Event-Related Potential Based Rapid Image Triage System

    Directory of Open Access Journals (Sweden)

    Ke Yu

    2011-06-01

    Full Text Available Searching for points of interest (POI in large-volume imagery is a challenging problem with few good solutions. In this work, a neural engineering approach called rapid image triage (RIT which could offer about a ten-fold speed up in POI searching is developed. It is essentially a cortically-coupled computer vision technique, whereby the user is presented bursts of images at a speed of 6–15 images per second and then neural signals called event-related potential (ERP is used as the ‘cue’ for user seeing images of high relevance likelihood. Compared to past efforts, the implemented system has several unique features: (1 it applies overlapping frames in image chip preparation, to ensure rapid image triage performance; (2 a novel common spatial-temporal pattern (CSTP algorithm that makes use of both spatial and temporal patterns of ERP topography is proposed for high-accuracy single-trial ERP detection; (3 a weighted version of probabilistic support-vector-machine (SVM is used to address the inherent unbalanced nature of single-trial ERP detection for RIT. High accuracy, fast learning, and real-time capability of the developed system shown on 20 subjects demonstrate the feasibility of a brainmachine integrated rapid image triage system for fast detection of POI from large-volume imagery.

  6. 'Rapid Learning health care in oncology' - an approach towards decision support systems enabling customised radiotherapy'.

    Science.gov (United States)

    Lambin, Philippe; Roelofs, Erik; Reymen, Bart; Velazquez, Emmanuel Rios; Buijsen, Jeroen; Zegers, Catharina M L; Carvalho, Sara; Leijenaar, Ralph T H; Nalbantov, Georgi; Oberije, Cary; Scott Marshall, M; Hoebers, Frank; Troost, Esther G C; van Stiphout, Ruud G P M; van Elmpt, Wouter; van der Weijden, Trudy; Boersma, Liesbeth; Valentini, Vincenzo; Dekker, Andre

    2013-10-01

    An overview of the Rapid Learning methodology, its results, and the potential impact on radiotherapy. Rapid Learning methodology is divided into four phases. In the data phase, diverse data are collected about past patients, treatments used, and outcomes. Innovative information technologies that support semantic interoperability enable distributed learning and data sharing without additional burden on health care professionals and without the need for data to leave the hospital. In the knowledge phase, prediction models are developed for new data and treatment outcomes by applying machine learning methods to data. In the application phase, this knowledge is applied in clinical practice via novel decision support systems or via extensions of existing models such as Tumour Control Probability models. In the evaluation phase, the predictability of treatment outcomes allows the new knowledge to be evaluated by comparing predicted and actual outcomes. Personalised or tailored cancer therapy ensures not only that patients receive an optimal treatment, but also that the right resources are being used for the right patients. Rapid Learning approaches combined with evidence based medicine are expected to improve the predictability of outcome and radiotherapy is the ideal field to study the value of Rapid Learning. The next step will be to include patient preferences in the decision making. Copyright © 2013 The Authors. Published by Elsevier Ireland Ltd.. All rights reserved.

  7. [Evaluation of a new blood gas analysis system: RapidPoint 500(®)].

    Science.gov (United States)

    Nicolas, Thierry; Cabrolier, Nadège; Bardonnet, Karine; Davani, Siamak

    2013-01-01

    We present here evaluation of a new blood gas analysis system, RapidPoint 500(®) (Siemens Healthcare Diagnostics). The aim of this research was to compare the ergonomics and analytical performances of this analyser with those of the RapidLab 1265 for the following parameters: pH, partial oxygen pressure, partial carbon dioxide pressure, sodium, potassium, ionized calcium, lactate and the CO-oximetry parameters: hemoglobin, oxyhemoglobin, carboxyhemoglobin, methemoglobin, reduced hemoglobin, neonatal bilirubin; as well as with the Dimension Vista 500 results for chloride and glucose. The Valtec protocol, recommended by the French Society of Clinical Biology (SFBC), was used to analyze the study results. The experiment was carried out over a period of one month in the Department of medical biochemistry. One hundred sixty five samples from adult patients admitted to the ER or hospitalized in intensive care were tested. The RapidPoint 500(®) was highly satisfactory from an ergonomic point of view. Intra-and inter- assay coefficients of variation (CV) with the three control levels were below those recommended by the SFBC for all parameters, and the comparative study gave coefficients of determination higher than 0.91. Taken together, the RapidPoint 500(®) appears fully satisfactory in terms of ergonomics and analytical performance.

  8. The Rapid Transit System That Achieves Higher Performance with Lower Life-Cycle Costs

    Science.gov (United States)

    Sone, Satoru; Takagi, Ryo

    In the age of traction system made of inverter and ac traction motors, distributed traction system with pure electric brake of regenerative mode has been recognised very advantageous. This paper proposes a new system as the lowest life-cycle cost system for high performance rapid transit, a new architecture and optimum parameters of power feeding system, and a new running method of trains. In Japan, these components of this proposal, i.e. pure electric brake and various countermeasures of reducing loss of regeneration have been already popular but not as yet the new running method for better utilisation of the equipment and for lower life-cycle cost. One example of what are proposed in this paper will be made as Tsukuba Express, which is under construction as the most modern commuter railway in Greater Tokyo area.

  9. Advanced diffusion system for low contamination in-line rapid thermal processing of silicon solar cells

    Energy Technology Data Exchange (ETDEWEB)

    Biro, D.; Preu, R.; Schultz, O.; Peters, S.; Huljic, D.M.; Zickermann, D.; Schindler, R.; Luedemann, R.; Willeke, G. [Fraunhofer Institute for Solar Energy Systems ISE, Freiburg (Germany)

    2002-10-01

    A novel diffusion system for in-line rapid thermal diffusion is presented. The lamp-heated furnace has a low thermal mass and a metal free transport system based on the walking beam principle. The furnace has been used to process first solar cells with lightly and highly doped emitters respectively. Solar cells with shallow lightly doped emitters show that the emitters processed in the new device can be well passivated. Shallow emitters with sheet resistances of up to 40/sq. have been contacted successfully by means of screen printing and firing through a SiN{sub x} antireflection coating. (author)

  10. Development of rapid detection system on BEPC Ⅱ magnet power supply

    International Nuclear Information System (INIS)

    Chen Suying; Zhan Mingchuan; Long Fengli; Ye Weidong

    2014-01-01

    To quickly find the causes of the accelerator unstable or lost beam caused by magnet power supply in Beijing Electron Positron Collider (BEPC Ⅱ) running, the rapid detection system for magnet power supply was developed. The stability of the system in 8 h is about 0.005%, and it can acquire over nearly 500 sets of magnet power supply current values most quickly in 0.33 ms. All data were written to the MySQL database in real time, so as to be able to quickly troubleshoot magnet power supply problem through historical data analysis and comparison. (authors)

  11. Rapid identification of herbal compounds derived metabolites using zebrafish larvae as the biotransformation system.

    Science.gov (United States)

    Wang, Chen; Yin, Ying-Hao; Wei, Ying-Jie; Shi, Zi-Qi; Liu, Jian-Qun; Liu, Li-Fang; Xin, Gui-Zhong

    2017-09-15

    Metabolites derived from herbal compounds are becoming promising sources for discovering new drugs. However, the rapid identification of metabolites from biological matrixes is limited by massive endogenous interference and low abundance of metabolites. Thus, by using zebrafish larvae as the biotransformation system, we herein proposed and validated an integrated strategy for rapid identification of metabolites derived from herbal compounds. Two pivotal steps involved in this strategy are to differentiate metabolites from herbal compounds and match metabolites with their parent compounds. The differentiation step was achieved by cross orthogonal partial least-squares discriminant analysis. Automatic matching analysis was performed on R Project based on a self-developed program, of which the number of matched ionic clusters and its corresponding percentage between metabolite and parent compound were taken into account to assess their similarity. Using this strategy, 46 metabolites screened from incubation water samples of zebrafish treated with total Epimedium flavonoids (EFs) could be matched with their corresponding parent compounds, 37 of them were identified and validated by the known metabolic pathways and fragmentation patterns. Finally, 75% of the identified EFs metabolites were successfully detected in urine samples of rats treated with EFs. These experimental results indicate that the proposed strategy using zebrafish larvae as the biotransformation system will facilitate the rapid identification of metabolites derived from herbal compounds, which shows promising perspectives in providing additional resources for pharmaceutical developments from natural products. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Rapid hydrogen charging on metal hydride negative electrode of Fuel Cell/Battery (FCB) systems

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Bokkyu; Lee, Sunmook; Kawai, Hiroyuki; Fushimi, Chihiro; Tsutsumi, Atsushi [Collaborative Research Center for Energy Engineering, Institute of Industrial Science, The University of Tokyo, 4-6-1 Komaba, Meguro-ku, Tokyo 153-8505 (Japan)

    2009-02-15

    The characteristics of rapid gaseous H{sub 2} charging/electrochemical discharging of the metal hydride negative electrode were investigated for the application in Fuel Cell/Battery (FCB) systems. They were evaluated with the H{sub 2} gas absorption, followed by the subsequent electrochemical discharging in the electrolyte solution (6M KOH). Then, the cyclability of charge-discharge was also examined. It was observed that more than 70% of the theoretical capacity was charged within 10 min with 0.3 MPa and 0.5 MPa of the initial H{sub 2} pressures. The electrochemical discharge curve showed that more than 86% of the absorbed H{sub 2} was discharged. Furthermore, the cycled charge-discharge process indicated that the H{sub 2} gas charge and electrochemical discharge process is an effective way to rapidly charge and activate the metal hydride without degeneration. (author)

  13. Portable microfluidic raman system for rapid, label-free early disease signature detection

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Meiye [Sandia National Laboratories (SNL-CA), Livermore, CA (United States); Davis, Ryan Wesley [Sandia National Laboratories (SNL-CA), Livermore, CA (United States); Hatch, Anson [Sandia National Laboratories (SNL-CA), Livermore, CA (United States)

    2015-09-01

    In the early stages of infection, patients develop non-specific or no symptoms at all. While waiting for identification of the infectious agent, precious window of opportunity for early intervention is lost. The standard diagnostics require affinity reagents and sufficient pathogen titers to reach the limit of detection. In the event of a disease outbreak, triaging the at-risk population rapidly and reliably for quarantine and countermeasure is more important than the identification of the pathogen by name. To expand Sandia's portfolio of Biological threat management capabilities, we will utilize Raman spectrometry to analyze immune subsets in whole blood to rapidly distinguish infected from non-infected, and bacterial from viral infection, for the purpose of triage during an emergency outbreak. The goal of this one year LDRD is to determine whether Raman spectroscopy can provide label-free detection of early disease signatures, and define a miniaturized Raman detection system meeting requirements for low- resource settings.

  14. Rapid analysis of hay attributes using NIRS. Final report, Task II alfalfa supply system

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-10-24

    This final report provides technical information on the development of a near infrared reflectance spectroscopy (NIRS) system for the analysis of alfalfa hay. The purpose of the system is to provide consistent quality for processing alfalfa stems for fuel and alfalfa leaf meal products for livestock feed. Project tasks were to: (1) develop an NIRS driven analytical system for analysis of alfalfa hay and processed alfalfa products; (2) assist in hiring a qualified NIRS technician and recommend changes in testing equipment necessary to provide accurate analysis; (3) calibrate the NIRS instrument for accurate analyses; and (4) develop prototype equipment and sampling procedures as a first step towards development of a totally automated sampling system that would rapidly sample and record incoming feedstock and outbound product. An accurate hay testing program was developed, along with calibration equations for analyzing alfalfa hay and sun-cured alfalfa pellets. A preliminary leaf steam calibration protocol was also developed. 7 refs., 11 figs., 10 tabs.

  15. M-dwarf rapid rotators and the detection of relatively young multiple M-star systems

    International Nuclear Information System (INIS)

    Rappaport, S.; Joss, M.; Sanchis-Ojeda, R.

    2014-01-01

    We have searched the Kepler light curves of ∼3900 M-star targets for evidence of periodicities that indicate, by means of the effects of starspots, rapid stellar rotation. Several analysis techniques, including Fourier transforms, inspection of folded light curves, 'sonograms', and phase tracking of individual modulation cycles, were applied in order to distinguish the periodicities due to rapid rotation from those due to stellar pulsations, eclipsing binaries, or transiting planets. We find 178 Kepler M-star targets with rotation periods, P rot , of <2 days, and 110 with P rot < 1 day. Some 30 of the 178 systems exhibit two or more independent short periods within the same Kepler photometric aperture, while several have 3 or more short periods. Adaptive optics imaging and modeling of the Kepler pixel response function for a subset of our sample support the conclusion that the targets with multiple periods are highly likely to be relatively young physical binary, triple, and even quadruple M star systems. We explore in detail the one object with four incommensurate periods all less than 1.2 days, and show that two of the periods arise from one of a close pair of stars, while the other two arise from the second star, which itself is probably a visual binary. If most of these M-star systems with multiple periods turn out to be bound M stars, this could prove a valuable way discovering young hierarchical M-star systems; the same approach may also be applicable to G and K stars. The ∼5% occurrence rate of rapid rotation among the ∼3900 M star targets is consistent with spin evolution models that include an initial contraction phase followed by magnetic braking, wherein a typical M star can spend several hundred Myr before spinning down to periods longer than 2 days.

  16. Noninvasive optoacoustic system for rapid diagnostics and management of circulatory shock

    Science.gov (United States)

    Esenaliev, Rinat O.; Petrov, Irene Y.; Petrov, Yuriy; Kinsky, Michael; Prough, Donald S.

    2012-02-01

    Circulatory shock is lethal, if not promptly diagnosed and effectively treated. Typically, circulatory shock resuscitation is guided by blood pressure, heart rate, and mental status, which have poor predictive value. In patients, in whom early goaldirected therapy was applied using central venous oxygenation measurement, a substantial reduction of mortality was reported (from 46.5% to 30%). However, central venous catheterization is invasive, time-consuming and often results in complications. We proposed to use the optoacoustic technique for noninvasive, rapid assessment of central venous oxygenation. In our previous works we demonstrated that the optoacoustic technique can provide measurement of blood oxygenation in veins and arteries due to high contrast and high resolution. In this work we developed a novel optoacoustic system for noninvasive, automatic, real-time, and continuous measurement of central venous oxygenation. We performed pilot clinical tests of the system in human subjects with different oxygenation in the internal jugular vein and subclavian vein. A novel optoacoustic interface incorporating highly-sensitive optoacoustic probes and standard ultrasound imaging probes were developed and built for the study. Ultrasound imaging systems Vivid i and hand-held Vscan (GE Healthcare) as well as Site-Rite 5 (C.R. Bard) were used in the study. We developed a special algorithm for oxygenation monitoring with minimal influence of overlying tissue. The data demonstrate that the system provides precise measurement of venous oxygenation continuously and in real time. Both current value of the venous oxygenation and trend (in absolute values and for specified time intervals) are displayed in the system. The data indicate that: 1) the optoacoustic system developed by our group is capable of noninvasive measurement of blood oxygenation in specific veins; 2) clinical ultrasound imaging systems can facilitate optoacoustic probing of specific blood vessels; 3) the

  17. An improved ternary vector system for Agrobacterium-mediated rapid maize transformation.

    Science.gov (United States)

    Anand, Ajith; Bass, Steven H; Wu, Emily; Wang, Ning; McBride, Kevin E; Annaluru, Narayana; Miller, Michael; Hua, Mo; Jones, Todd J

    2018-05-01

    A simple and versatile ternary vector system that utilizes improved accessory plasmids for rapid maize transformation is described. This system facilitates high-throughput vector construction and plant transformation. The super binary plasmid pSB1 is a mainstay of maize transformation. However, the large size of the base vector makes it challenging to clone, the process of co-integration is cumbersome and inefficient, and some Agrobacterium strains are known to give rise to spontaneous mutants resistant to tetracycline. These limitations present substantial barriers to high throughput vector construction. Here we describe a smaller, simpler and versatile ternary vector system for maize transformation that utilizes improved accessory plasmids requiring no co-integration step. In addition, the newly described accessory plasmids have restored virulence genes found to be defective in pSB1, as well as added virulence genes. Testing of different configurations of the accessory plasmids in combination with T-DNA binary vector as ternary vectors nearly doubles both the raw transformation frequency and the number of transformation events of usable quality in difficult-to-transform maize inbreds. The newly described ternary vectors enabled the development of a rapid maize transformation method for elite inbreds. This vector system facilitated screening different origins of replication on the accessory plasmid and T-DNA vector, and four combinations were identified that have high (86-103%) raw transformation frequency in an elite maize inbred.

  18. 49 CFR 37.81 - Purchase or lease of used rail vehicles by public entities operating rapid or light rail systems.

    Science.gov (United States)

    2010-10-01

    ... entities operating rapid or light rail systems. 37.81 Section 37.81 Transportation Office of the Secretary... operating rapid or light rail systems. (a) Except as provided elsewhere in this section, each public entity operating a rapid or light rail system which, after August 25, 1990, purchases or leases a used rapid or...

  19. Maize Cropping Systems Mapping Using RapidEye Observations in Agro-Ecological Landscapes in Kenya.

    Science.gov (United States)

    Richard, Kyalo; Abdel-Rahman, Elfatih M; Subramanian, Sevgan; Nyasani, Johnson O; Thiel, Michael; Jozani, Hosein; Borgemeister, Christian; Landmann, Tobias

    2017-11-03

    Cropping systems information on explicit scales is an important but rarely available variable in many crops modeling routines and of utmost importance for understanding pests and disease propagation mechanisms in agro-ecological landscapes. In this study, high spatial and temporal resolution RapidEye bio-temporal data were utilized within a novel 2-step hierarchical random forest (RF) classification approach to map areas of mono- and mixed maize cropping systems. A small-scale maize farming site in Machakos County, Kenya was used as a study site. Within the study site, field data was collected during the satellite acquisition period on general land use/land cover (LULC) and the two cropping systems. Firstly, non-cropland areas were masked out from other land use/land cover using the LULC mapping result. Subsequently an optimized RF model was applied to the cropland layer to map the two cropping systems (2nd classification step). An overall accuracy of 93% was attained for the LULC classification, while the class accuracies (PA: producer's accuracy and UA: user's accuracy) for the two cropping systems were consistently above 85%. We concluded that explicit mapping of different cropping systems is feasible in complex and highly fragmented agro-ecological landscapes if high resolution and multi-temporal satellite data such as 5 m RapidEye data is employed. Further research is needed on the feasibility of using freely available 10-20 m Sentinel-2 data for wide-area assessment of cropping systems as an important variable in numerous crop productivity models.

  20. Maize Cropping Systems Mapping Using RapidEye Observations in Agro-Ecological Landscapes in Kenya

    Directory of Open Access Journals (Sweden)

    Kyalo Richard

    2017-11-01

    Full Text Available Cropping systems information on explicit scales is an important but rarely available variable in many crops modeling routines and of utmost importance for understanding pests and disease propagation mechanisms in agro-ecological landscapes. In this study, high spatial and temporal resolution RapidEye bio-temporal data were utilized within a novel 2-step hierarchical random forest (RF classification approach to map areas of mono- and mixed maize cropping systems. A small-scale maize farming site in Machakos County, Kenya was used as a study site. Within the study site, field data was collected during the satellite acquisition period on general land use/land cover (LULC and the two cropping systems. Firstly, non-cropland areas were masked out from other land use/land cover using the LULC mapping result. Subsequently an optimized RF model was applied to the cropland layer to map the two cropping systems (2nd classification step. An overall accuracy of 93% was attained for the LULC classification, while the class accuracies (PA: producer’s accuracy and UA: user’s accuracy for the two cropping systems were consistently above 85%. We concluded that explicit mapping of different cropping systems is feasible in complex and highly fragmented agro-ecological landscapes if high resolution and multi-temporal satellite data such as 5 m RapidEye data is employed. Further research is needed on the feasibility of using freely available 10–20 m Sentinel-2 data for wide-area assessment of cropping systems as an important variable in numerous crop productivity models.

  1. Rapid Active Power Control of Photovoltaic Systems for Grid Frequency Support

    Energy Technology Data Exchange (ETDEWEB)

    Hoke, Anderson; Shirazi, Mariko; Chakraborty, Sudipta; Muljadi, Eduard; Maksimovic, Dragan

    2017-01-01

    As deployment of power electronic coupled generation such as photovoltaic (PV) systems increases, grid operators have shown increasing interest in calling on inverter-coupled generation to help mitigate frequency contingency events by rapidly surging active power into the grid. When responding to contingency events, the faster the active power is provided, the more effective it may be for arresting the frequency event. This paper proposes a predictive PV inverter control method for very fast and accurate control of active power. This rapid active power control method will increase the effectiveness of various higher-level controls designed to mitigate grid frequency contingency events, including fast power-frequency droop, inertia emulation, and fast frequency response, without the need for energy storage. The rapid active power control method, coupled with a maximum power point estimation method, is implemented in a prototype PV inverter connected to a PV array. The prototype inverter's response to various frequency events is experimentally confirmed to be fast (beginning within 2 line cycles and completing within 4.5 line cycles of a severe test event) and accurate (below 2% steady-state error).

  2. A rapid and continuous system for immobilization of nuclear material waste by vitrification

    International Nuclear Information System (INIS)

    Shareef, M.U.; Hussain, S.H.; Tufail, M.; Rashid, F.

    2009-01-01

    The nuclear technology has prime importance and backbone for rapid development of medical sciences, industries and in power generation as an alternate source of energy. Despite all these facts there is a major problem which is always associated with nuclear technology, that is, the generation of undesirable radioactive wastes. The radioactive wastes are quite problematic and need major attention for its treatment, conditioning and properly disposal to keep the environmental activities and human ecosystem healthy and safe. There are different large scale methods and processes to treat and dispose off the radioactive wastes. These processes are evaluated and designed by the various world competent and pronounced scientists in the light of rules and safety limits set by IAEA and other regulatory authorities to protect the environment and eventually protect our ecosystem. The research and development work on radioactive waste has been proceeding for the last fifty years but still it is a core issue and a big challenge for the nuclear scientists and radiation workers. In this study a rapid and continuous system for immobilization of nuclear waste into glass matrix by vitrification has been designed. In general treatment methods, Borosilicate glass is preferred because it is efficient, cost effective and rapid to that of other radioactive waste form. In this process the simulated waste is mixed with glass forming material and process for melting to form a glassy substrate in continuous manner. The waste is being converted into vitreous form and encapsulate into a glass matrix. (author)

  3. a Method for Preview Vibration Control of Systems Having Forcing Inputs and Rapidly-Switched Dampers

    Science.gov (United States)

    ElBeheiry, E. M.

    1998-07-01

    In a variety of applications, especially in large scale dynamic systems, the mechanization of different vibration control elements in different locations would be decided by limitations placed on the modal vibration of the system and the inherent dynamic coupling between its modes. Also, the quality of vibration control to the economy of producing the whole system would be another trade-off leading to a mix of passive, active and semi-active vibration control elements in one system. This termactiveis limited to externally powered vibration control inputs and the termsemi-activeis limited to rapidly switched dampers. In this article, an optimal preview control method is developed for application to dynamic systems having active and semi-active vibration control elements mechanized at different locations in one system. The system is then a piecewise (bilinear) controller in which two independent sets of control inputs appear additively and multiplicatively. Calculus of variations along with the Hamiltonian approach are employed for the derivation of this method. In essence, it requires the active elements to be ideal force generators and the switched dampers to have the property of on-line variation of the damping characteristics to pre-determined limits. As the dampers switch during operation the whole system's structure differs, and then values of the active forcing inputs are adapted to match these rapid changes. Strictly speaking, each rapidly switched damper has pre-known upper and lower damping levels and it can take on any in-between value. This in-between value is to be determined by the method as long as the damper tracks a pre-known fully active control demand. In every damping state of each semi-active damper the method provides the optimal matching values of the active forcing inputs. The method is shown to have the feature of solving simple standard matrix equations to obtain closed form solutions. A comprehensive 9-DOF tractor semi-trailer model is used

  4. Incorporating rapid neocortical learning of new schema-consistent information into complementary learning systems theory.

    Science.gov (United States)

    McClelland, James L

    2013-11-01

    The complementary learning systems theory of the roles of hippocampus and neocortex (McClelland, McNaughton, & O'Reilly, 1995) holds that the rapid integration of arbitrary new information into neocortical structures is avoided to prevent catastrophic interference with structured knowledge representations stored in synaptic connections among neocortical neurons. Recent studies (Tse et al., 2007, 2011) showed that neocortical circuits can rapidly acquire new associations that are consistent with prior knowledge. The findings challenge the complementary learning systems theory as previously presented. However, new simulations extending those reported in McClelland et al. (1995) show that new information that is consistent with knowledge previously acquired by a putatively cortexlike artificial neural network can be learned rapidly and without interfering with existing knowledge; it is when inconsistent new knowledge is acquired quickly that catastrophic interference ensues. Several important features of the findings of Tse et al. (2007, 2011) are captured in these simulations, indicating that the neural network model used in McClelland et al. has characteristics in common with neocortical learning mechanisms. An additional simulation generalizes beyond the network model previously used, showing how the rate of change of cortical connections can depend on prior knowledge in an arguably more biologically plausible network architecture. In sum, the findings of Tse et al. are fully consistent with the idea that hippocampus and neocortex are complementary learning systems. Taken together, these findings and the simulations reported here advance our knowledge by bringing out the role of consistency of new experience with existing knowledge and demonstrating that the rate of change of connections in real and artificial neural networks can be strongly prior-knowledge dependent. PsycINFO Database Record (c) 2013 APA, all rights reserved.

  5. Rapid prototyping of soil moisture estimates using the NASA Land Information System

    Science.gov (United States)

    Anantharaj, V.; Mostovoy, G.; Li, B.; Peters-Lidard, C.; Houser, P.; Moorhead, R.; Kumar, S.

    2007-12-01

    The Land Information System (LIS), developed at the NASA Goddard Space Flight Center, is a functional Land Data Assimilation System (LDAS) that incorporates a suite of land models in an interoperable computational framework. LIS has been integrated into a computational Rapid Prototyping Capabilities (RPC) infrastructure. LIS consists of a core, a number of community land models, data servers, and visualization systems - integrated in a high-performance computing environment. The land surface models (LSM) in LIS incorporate surface and atmospheric parameters of temperature, snow/water, vegetation, albedo, soil conditions, topography, and radiation. Many of these parameters are available from in-situ observations, numerical model analysis, and from NASA, NOAA, and other remote sensing satellite platforms at various spatial and temporal resolutions. The computational resources, available to LIS via the RPC infrastructure, support e- Science experiments involving the global modeling of land-atmosphere studies at 1km spatial resolutions as well as regional studies at finer resolutions. The Noah Land Surface Model, available with-in the LIS is being used to rapidly prototype soil moisture estimates in order to evaluate the viability of other science applications for decision making purposes. For example, LIS has been used to further extend the utility of the USDA Soil Climate Analysis Network of in-situ soil moisture observations. In addition, LIS also supports data assimilation capabilities that are used to assimilate remotely sensed soil moisture retrievals from the AMSR-E instrument onboard the Aqua satellite. The rapid prototyping of soil moisture estimates using LIS and their applications will be illustrated during the presentation.

  6. Charge Energy Transport in Hopping Systems with Rapidly Decreasing Density of States

    Science.gov (United States)

    Mendels, Dan; Organic Electronics Group Technion Team

    2014-03-01

    An accurate description of the carrier hopping topology in the energy domain of hopping systems incorporating a rapidly decreasing density of states and the subsequent energetic position of these systems' so called effective conduction band is crucial for rationalizing and quantifying these systems' thermo-electric properties, doping related phenomena and carrier gradient effects such as the emergence of the General Einstein Relation under degenerate conditions. Additionally, as will be shown, the 'mobile' carriers propagating through the system can have excess energies reaching 0.3eV above the system quasi-Fermi energy. Hence, since these mobile carriers are most prone to reach systems interfaces and interact with oppositely charged carriers, their excess energy should be considered in determining the efficiencies of energy dependent processes such as carrier recombination and exciton dissociation. In light of the stated motivations, a comprehensive numerical and analytical study of the topology of hopping in the energetic density of such systems (i.e. the statistics regarding which energy values carriers visit most and in what manner) was implemented and the main statistical features of the hopping process that determine the position in energy of the system's effective conduction band were distilled. The obtained results also help shed light on yet to be elucidated discrepancies between predictions given by the widely employed transport energy concept and Monte Carlo simulations.

  7. Virtual Simulator for Autonomous Mobile Robots Navigation System Using Concepts of Control Rapid Prototyping

    Directory of Open Access Journals (Sweden)

    Leonimer Flavio de Melo

    2013-09-01

    Full Text Available This work presents the proposal of virtual environment implementation for project simulation and conception of supervision and control systems for mobile robots, that are capable to operate and adapting in different environments and conditions. This virtual system has as purpose to facilitate the development of embedded architecture systems, emphasizing the implementation of tools that allow the simulation of the kinematic conditions, dynamic and control, with real time monitoring of all important system points. For this, open control architecture is proposal, integrating the two main techniques of robotic control implementation in the hardware level: systems microprocessors and reconfigurable hardware devices. The implemented simulator system is composed of a trajectory generating module, a kinematic and dynamic simulator module and of a analysis module of results and errors. The kinematic and dynamic simulator module makes all simulation of the mobile robot following the pre-determined trajectory of the trajectory generator. All the kinematic and dynamic results shown during the simulation can be evaluated and visualized in graphs and tables formats, in the results analysis module, allowing an improvement in the system, minimizing the errors with the necessary adjustments optimization. For controller implementation in the embedded system, it uses the rapid prototyping, which is the technology that allows, in set with the virtual simulation environment, the development of a controller project for mobile robots. The validation and tests had been accomplishing with nonholonomics mobile robots models with differential transmission.

  8. Rapid stress system drives chemical transfer of fear from sender to receiver.

    Directory of Open Access Journals (Sweden)

    Jasper H B de Groot

    Full Text Available Humans can register another person's fear not only with their eyes and ears, but also with their nose. Previous research has demonstrated that exposure to body odors from fearful individuals elicited implicit fear in others. The odor of fearful individuals appears to have a distinctive signature that can be produced relatively rapidly, driven by a physiological mechanism that has remained unexplored in earlier research. The apocrine sweat glands in the armpit that are responsible for chemosignal production contain receptors for adrenalin. We therefore expected that the release of adrenalin through activation of the rapid stress response system (i.e., the sympathetic-adrenal medullary system is what drives the release of fear sweat, as opposed to activation of the slower stress response system (i.e., hypothalamus-pituitary-adrenal axis. To test this assumption, sweat was sampled while eight participants prepared for a speech. Participants had higher heart rates and produced more armpit sweat in the fast stress condition, compared to baseline and the slow stress condition. Importantly, exposure to sweat from participants in the fast stress condition induced in receivers (N = 31 a simulacrum of the state of the sender, evidenced by the emergence of a fearful facial expression (facial electromyography and vigilant behavior (i.e., faster classification of emotional facial expressions.

  9. Rapid response and wide range neutronic power measuring systems for fast pulsed reactors

    International Nuclear Information System (INIS)

    Sumita, Kenji; Iida, Toshiyuki; Wakayama, Naoaki.

    1976-01-01

    This paper summarizes our investigation on design principles of the rapid, stable and wide range neutronic power measuring system for fast pulsed reactors. The picoammeter, the logarithmic amplifier, the reactivity meter and the neutron current chamber are the items of investigation. In order to get a rapid response, the method of compensation for the stray capacitance of the feedback circuits and the capacitance of signal cables is applied to the picoammeter, the logarithmic amplifier and the reactivity meter with consideration for the stability margin of a whole detecting system. The response of an ionization current chamber and the method for compensating the ion component of the chamber output to get optimum responses high pass filters are investigated. Statistical fluctuations of the current chamber output are also considered in those works. The optimum thickness of the surrounding moderator of the neutron detector is also discussed from the viewpoint of the pulse shape deformation and the neutron sensitivity increase. The experimental results are reported, which were observed in the pulse operations of the one shot fast pulsed reactor ''YAYOI'' and the one shot TRIGA ''NSRR'' with the measuring systems using those principles. (auth.)

  10. Rapid prototyping of microfluidic systems using a PDMS/polymer tape composite.

    Science.gov (United States)

    Kim, Jungkyu; Surapaneni, Rajesh; Gale, Bruce K

    2009-05-07

    Rapid prototyping of microfluidic systems using a combination of double-sided tape and PDMS (polydimethylsiloxane) is introduced. PDMS is typically difficult to bond using adhesive tapes due to its hydrophobic nature and low surface energy. For this reason, PDMS is not compatible with the xurography method, which uses a knife plotter and various adhesive coated polymer tapes. To solve these problems, a PDMS/tape composite was developed and demonstrated in microfluidic applications. The PDMS/tape composite was created by spinning it to make a thin layer of PDMS over double-sided tape. Then the PDMS/tape composite was patterned to create channels using xurography, and bonded to a PDMS slab. After removing the backing paper from the tape, a complete microfluidic system could be created by placing the construct onto nearly any substrate; including glass, plastic or metal-coated glass/silicon substrates. The bond strength was shown to be sufficient for the pressures that occur in typical microfluidic channels used for chemical or biological analysis. This method was demonstrated in three applications: standard microfluidic channels and reactors, a microfluidic system with an integrated membrane, and an electrochemical biosensor. The PDMS/tape composite rapid prototyping technique provides a fast and cost effective fabrication method and can provide easy integration of microfluidic channels with sensors and other components without the need for a cleanroom facility.

  11. Research on rapid agile metrology for manufacturing based on real-time multitask operating system

    Science.gov (United States)

    Chen, Jihong; Song, Zhen; Yang, Daoshan; Zhou, Ji; Buckley, Shawn

    1996-10-01

    Rapid agile metrology for manufacturing (RAMM) using multiple non-contact sensors is likely to remain a growing trend in manufacturing. High speed inspecting systems for manufacturing is characterized by multitasks implemented in parallel and real-time events which occur simultaneously. In this paper, we introduce a real-time operating system into RAMM research. A general task model of a class-based object- oriented technology is proposed. A general multitask frame of a typical RAMM system using OPNet is discussed. Finally, an application example of a machine which inspects parts held on a carrier strip is described. With RTOS and OPNet, this machine can measure two dimensions of the contacts at 300 parts/second.

  12. Rapid Inventory Collection System (RICS) and the 2009 Victorian Bushfires impact assessment

    Energy Technology Data Exchange (ETDEWEB)

    Habili, N; Corby, N; Cechet, R P, E-mail: nariman.habili@ga.gov.a [Risk and Impact Analysis Group, Geoscience Australia G.PO Box 378, Canberra, Australian Capital Territory (Australia)

    2010-08-15

    The Rapid Inventory Collection System (RICS) is a vehicular data collection system (image and GPS) used for building/infrastructure damage and inventory assessment. The system consists of Ethernet cameras attached to a tripod mounted on a motor vehicle, a GPS receiver and software written in C++. RICS was deployed following the 2009 Victorian Bushfires and the collected data was used by the Victorian Bushfires Royal Commission for the impact assessment (field survey) which quantified the extent and severity of the damage caused to residential buildings by the fire-storm. The regions of Kilmore East, Murrindindi, Churchill, Maiden Gully - Bendigo and Bunyip had nearly 5400 residential structures within the fire perimeter. Analysis utilising both aerial and vehicular (RICS) imagery indicates that just over 2100 homes were destroyed and an additional 800 received minor damage.

  13. Optical code division multiple access secure communications systems with rapid reconfigurable polarization shift key user code

    Science.gov (United States)

    Gao, Kaiqiang; Wu, Chongqing; Sheng, Xinzhi; Shang, Chao; Liu, Lanlan; Wang, Jian

    2015-09-01

    An optical code division multiple access (OCDMA) secure communications system scheme with rapid reconfigurable polarization shift key (Pol-SK) bipolar user code is proposed and demonstrated. Compared to fix code OCDMA, by constantly changing the user code, the performance of anti-eavesdropping is greatly improved. The Pol-SK OCDMA experiment with a 10 Gchip/s user code and a 1.25 Gb/s user data of payload has been realized, which means this scheme has better tolerance and could be easily realized.

  14. 10 kW Contactless Power Transfer System for Rapid Charger of Electric Vehicle

    OpenAIRE

    Yamanaka, Tomohiro; Kaneko, Yasuyoshi; Abe, Shigeru; Yasuda, Tomio

    2012-01-01

    A contactless power transfer system for charging electric vehicles requires a high efficiency, a large air gap, and a good tolerance to lateral misalignment and needs to be compact and lightweight. A double-sided winding 10 kW transformer based on a 1.5 kW H-shaped core transformer was developed for a rapid charger. Even though the transformer capacity was increased, the dimensions of the 10 kW transformer were almost the same as those of the 1.5 kW transformer. In this paper, the design conc...

  15. A simple, rapid, and sensitive system for the evaluation of anti-viral drugs in rats

    Energy Technology Data Exchange (ETDEWEB)

    Li, Xiaoguang [Tohoku University Graduate School of Medicine, Department of Internal Medicine/Division of Emerging Infectious Diseases, Sendai 980-8575 (Japan); Department of Medical Microbiology, Harbin Medical University, Harbin 150086 (China); Center for AIDS Research, Kumamoto University, 2-2-1 Honjo, Kumamoto 860-0811 (Japan); Qian, Hua [Tohoku University Graduate School of Medicine, Department of Internal Medicine/Division of Emerging Infectious Diseases, Sendai 980-8575 (Japan); Center for AIDS Research, Kumamoto University, 2-2-1 Honjo, Kumamoto 860-0811 (Japan); Miyamoto, Fusako [Tohoku University Graduate School of Medicine, Department of Internal Medicine/Division of Emerging Infectious Diseases, Sendai 980-8575 (Japan); Naito, Takeshi [Laboratory of Virus Control, Institute for Virus Research, Kyoto University, 53 Kawaramachi, Shogoin, Sakyo-ku, Kyoto 606-8507 (Japan); Kawaji, Kumi [Tohoku University Graduate School of Medicine, Department of Internal Medicine/Division of Emerging Infectious Diseases, Sendai 980-8575 (Japan); Kajiwara, Kazumi [Graduate School of Pharmaceutical Sciences, Kyoto University, Sakyo-ku, Kyoto 606-8501 (Japan); JST Innovation Plaza Kyoto, Japan Science and Technology Agency, Nishigyo-ku, Kyoto 615-8245 (Japan); Hattori, Toshio [Tohoku University Graduate School of Medicine, Department of Internal Medicine/Division of Emerging Infectious Diseases, Sendai 980-8575 (Japan); Matsuoka, Masao [Laboratory of Virus Control, Institute for Virus Research, Kyoto University, 53 Kawaramachi, Shogoin, Sakyo-ku, Kyoto 606-8507 (Japan); Watanabe, Kentaro; Oishi, Shinya; Fujii, Nobutaka [Graduate School of Pharmaceutical Sciences, Kyoto University, Sakyo-ku, Kyoto 606-8501 (Japan); and others

    2012-07-27

    Highlights: Black-Right-Pointing-Pointer We established a novel, simple and rapid in vivo system for evaluation of anti-HIV-1 drugs with rats. Black-Right-Pointing-Pointer The system may be applicable for other antiviral drugs, and/or useful for initial screening in vivo. Black-Right-Pointing-Pointer In this system, TRI-1144 displayed the most potent anti-HIV-1 activity in vivo. -- Abstract: The lack of small animal models for the evaluation of anti-human immunodeficiency virus type 1 (HIV-1) agents hampers drug development. Here, we describe the establishment of a simple and rapid evaluation system in a rat model without animal infection facilities. After intraperitoneal administration of test drugs to rats, antiviral activity in the sera was examined by the MAGI assay. Recently developed inhibitors for HIV-1 entry, two CXCR4 antagonists, TF14016 and FC131, and four fusion inhibitors, T-20, T-20EK, SC29EK, and TRI-1144, were evaluated using HIV-1{sub IIIB} and HIV-1{sub BaL} as representative CXCR4- and CCR5-tropic HIV-1 strains, respectively. CXCR4 antagonists were shown to only possess anti-HIV-1{sub IIIB} activity, whereas fusion inhibitors showed both anti-HIV-1{sub IIIB} and anti-HIV-1{sub BaL} activities in rat sera. These results indicate that test drugs were successfully processed into the rat sera and could be detected by the MAGI assay. In this system, TRI-1144 showed the most potent and sustained antiviral activity. Sera from animals not administered drugs showed substantial anti-HIV-1 activity, indicating that relatively high dose or activity of the test drugs might be needed. In conclusion, the novel rat system established here, 'phenotypic drug evaluation', may be applicable for the evaluation of various antiviral drugs in vivo.

  16. A simple, rapid, and sensitive system for the evaluation of anti-viral drugs in rats

    International Nuclear Information System (INIS)

    Li, Xiaoguang; Qian, Hua; Miyamoto, Fusako; Naito, Takeshi; Kawaji, Kumi; Kajiwara, Kazumi; Hattori, Toshio; Matsuoka, Masao; Watanabe, Kentaro; Oishi, Shinya; Fujii, Nobutaka

    2012-01-01

    Highlights: ► We established a novel, simple and rapid in vivo system for evaluation of anti-HIV-1 drugs with rats. ► The system may be applicable for other antiviral drugs, and/or useful for initial screening in vivo. ► In this system, TRI-1144 displayed the most potent anti-HIV-1 activity in vivo. -- Abstract: The lack of small animal models for the evaluation of anti-human immunodeficiency virus type 1 (HIV-1) agents hampers drug development. Here, we describe the establishment of a simple and rapid evaluation system in a rat model without animal infection facilities. After intraperitoneal administration of test drugs to rats, antiviral activity in the sera was examined by the MAGI assay. Recently developed inhibitors for HIV-1 entry, two CXCR4 antagonists, TF14016 and FC131, and four fusion inhibitors, T-20, T-20EK, SC29EK, and TRI-1144, were evaluated using HIV-1 IIIB and HIV-1 BaL as representative CXCR4- and CCR5-tropic HIV-1 strains, respectively. CXCR4 antagonists were shown to only possess anti-HIV-1 IIIB activity, whereas fusion inhibitors showed both anti-HIV-1 IIIB and anti-HIV-1 BaL activities in rat sera. These results indicate that test drugs were successfully processed into the rat sera and could be detected by the MAGI assay. In this system, TRI-1144 showed the most potent and sustained antiviral activity. Sera from animals not administered drugs showed substantial anti-HIV-1 activity, indicating that relatively high dose or activity of the test drugs might be needed. In conclusion, the novel rat system established here, “phenotypic drug evaluation”, may be applicable for the evaluation of various antiviral drugs in vivo.

  17. Rapid Mental Сomputation System as a Tool for Algorithmic Thinking of Elementary School Students Development

    Directory of Open Access Journals (Sweden)

    Rushan Ziatdinov

    2012-07-01

    Full Text Available In this paper, we describe the possibilities of using a rapid mental computation system in elementary education. The system consists of a number of readily memorized operations that allow one to perform arithmetic computations very quickly. These operations are actually simple algorithms which can develop or improve the algorithmic thinking of pupils. Using a rapid mental computation system allows forming the basis for the study of computer science in secondary school.

  18. Enabling rapid behavioral ecotoxicity studies using an integrated lab-on-a-chip systems

    Science.gov (United States)

    Huang, Yushi; Nugegoda, Dayanthi; Wlodkowic, Donald

    2015-12-01

    Behavioral ecotoxicity tests are gaining an increasing recognition in environmental toxicology. Behavior of sensitive bioindicator species can change rapidly in response to an acute exposure to contaminants and thus has a much higher sensitivity as compared to conventional LC50 mortality tests. Furthermore, behavioral endpoints seems to be very good candidates to develop early-warning biomonitoring systems needed for rapid chemical risk assessment. Behavioral tests are non-invasive, fast, do not harm indicator organisms (behavioural changes are very rapid) and are thus fully compatible with 3R (Replacement - Reduction - Refinement) principle encouraging alternatives to conventional animal testing. These characteristics are essential when designing improved ecotoxicity tests for chemical risk assessment. In this work, we present a pilot development of miniaturized Lab-on-a-Chip (LOC) devices for studying toxin avoidance behaviors of small aquatic crustaceans. As an investigative tool, LOCs represent a new direction that may miniaturize and revolutionize behavioral ecotoxicology. Specifically our innovative microfluidic prototype: (i) enables convening "caging" of specimens for real-time videomicroscopy; (ii) eliminates the evaporative water loss thus providing an opportunity for long-term behavioral studies; (iii) exploits laminar fluid flow under low Reynolds numbers to generate discrete domains and gradients enabling for the first time toxin avoidance studies on small aquatic crustaceans; (iv) integrates off-the-chip mechatronic interfaces and video analysis algorithms for single animal movement analysis. We provide evidence that by merging innovative bioelectronic and biomicrofluidic technologies we can deploy inexpensive and reliable systems for culture, electronic tracking and complex computational analysis of behavior of bioindicator organisms.

  19. A computer-controlled system for rapid soil analysis of 226Ra

    International Nuclear Information System (INIS)

    Doane, R.W.; Berven, B.A.; Blair, M.S.

    1984-01-01

    A computer-controlled multichannel analysis system has been developed by the Radiological Survey Activities (RASA) Group at Oak Ridge National Laboratory (ORNL) for the Department of Energy (DOE) in support of the DOE's remedial action programs. The purpose of this system is to provide a rapid estimate of the 226 Ra concentration in soil samples using a 6 x 9 inch NaI(T1) crystal containing a 3.25 inch deep by 3.5 inch diameter well. This gamma detection system is controlled by a minicomputer with a dual floppy disk storage medium, line printer, and optional X-Y plotter. A two-chip interface was also designed at ORNL which handles all control signals generated from the computer keyboard. These computer-generated control signals are processed in machine language for rapid data transfer and BASIC language is used for data processing. The computer system is a Commodore Business Machines (CBM) Model 8032 personal computer with CBM peripherals. Control and data signals are utilized via the parallel user's port to the interface unit. The analog-to-digital converter (ADC) is controlled in machine language, bootstrapped to high memory, and is addressed through the BASIC program. The BASIC program is designed to be ''user friendly'' and provides the operator with several modes of operation such as background and analysis acquisition. Any number of energy regions-of-interest (ROI) may be analyzed with automatic background substraction. Also employed in the BASIC program are the 226 Ra algorithms which utilize linear and polynomial regression equations for data conversion and look-up tables for radon equilibrating coefficients. The optional X-Y plotter may be used with two- or three-dimensional curve programs to enhance data analysis and presentation. A description of the system is presented and typical applications are discussed

  20. Rapid Prototyping of the Central Safety System for Nuclear Risk in ITER

    Energy Technology Data Exchange (ETDEWEB)

    Scibile, L. [ITER Organization, 13 - St. Paul lez Durance (France); Ambrosino, G.; De Tommasi, G.; Pironti, A. [Euratom-ENEA-CREATE, Universita di Napoli Federico II, Napoli (Italy)

    2009-07-01

    Full text of publication follows: In the current ITER Baseline design, the Central Safety System for Nuclear Risk (CSS-N) is the safety control system in charge to assure nuclear safety for the plant, personnel and environment. In particular it is envisaged that the CSS shall interface to the plant safety systems for nuclear risk and shall coordinate the individual protection provided by the intervention of these systems by the activation, where required, of additional protections. The design of such a system, together with its implementation, strongly depends on the requirements, particularly in terms of reliability. The CSS-N is a safety critical system, thus its validation and commissioning play a very important role, since the required level of reliability must be demonstrated. In such a scenario, where a new and non-conventional system has to be deployed, it is strongly recommended to use modeling and simulation tools since the early design phase. Indeed, the modeling tools will help in the definition of the system requirements, and they will be used to test and validate the control logic. Furthermore these tools can be used to rapid design the safety system and to carry out hardware-in-the-loop (HIL) simulations, which permit to assess the performance of the control hardware against a plant simulator. Both a control system prototype and a safety system oriented plant simulator have been developed to assess first the requirements and then the performance of the CSS-N. In particular the presented SW/HW framework permits to design and verify the CSS protection logics and to test and validate these logics by means of HIL simulations. This work introduces both the prototype and plant simulator architectures, together with the methodology adopted to design and implement these validation tools. (authors)

  1. Rapid islanding detection using multi-level inverter for grid-interactive PV system

    International Nuclear Information System (INIS)

    Tsang, K.M.; Chan, W.L.

    2014-01-01

    Graphical abstract: - Highlights: • Novel reference signal is used to form an islanding detection scheme for PV system. • Supply fixed magnitude sinusoidal signal even if utility grid is disconnected. • Seamless transfer between grid-connected and stand-alone modes is possible. - Abstract: A novel reference signal generator is combined with a multi-level inverter to form a rapid islanding detection scheme for grid-interactive PV system. The reference signal generator can easily be synchronized with the utility grid signal and produced a fixed magnitude and very low total harmonic distortion (THD) sinusoidal signal which is in phase with the utility grid signal. Unlike conventional phase-locked loop (PLL) circuitry, the reference signal generator can also provide a fixed magnitude sinusoidal signal even if the utility grid is disconnected and automatically re-synchronous with the grid rapidly. Consequently, seamless transfer between grid-connected and stand-alone modes could easily be achieved if anti-islanding protection is not required. If a saturation element is applied to the raw reference signal followed by the synthesis of the truncated signal using a multi-level inverter, the distinct flat-top feature of the synthesized signal can quickly and easily be identified if the network is in islanding mode at the point of common coupling. Experimental results are included to demonstrate the effectiveness of the proposed detection scheme

  2. Rapid prototyping of the Central Safety System for Nuclear Risk in ITER

    Energy Technology Data Exchange (ETDEWEB)

    Scibile, L. [ITER Organization, CS 90 046, St. Paul-lez-Durance, Cedex (France); Ambrosino, G. [Consorzio CREATE, Universita degli Studi di Napoli Federico II, via Claudio 21, 80125, Napoli (Italy); De Tommasi, G., E-mail: detommas@unina.i [Consorzio CREATE, Universita degli Studi di Napoli Federico II, via Claudio 21, 80125, Napoli (Italy); Pironti, A. [Consorzio CREATE, Universita degli Studi di Napoli Federico II, via Claudio 21, 80125, Napoli (Italy)

    2010-07-15

    The Central Safety System for Nuclear Risk (CSS-N) coordinates the safety control systems to ensure nuclear safety for the ITER complex. Since the CSS-N is a safety critical system, its validation and commissioning play a very important role; in particular the required level of reliability must be demonstrated. In such a scenario, it is strongly recommended to use modeling and simulation tools since the early design phase. Indeed, the modeling tools will help in the definition of the control system requirements. Furthermore the models can than be used for the rapid prototyping of the safety system. Hardware-in-the-loop simulations can also be performed in order to assess the performance of the control hardware against a plant simulator. The proposed approach relies on the availability of a plant simulator to develop the prototype of the control system. This paper introduces the methodology used to design and develop both the CSS-N Oriented Plant Simulator and the CSS-N Prototype.

  3. A rapid-exchange monorail stent system for salvage of failing femoropopliteal bypass grafts.

    Science.gov (United States)

    Jahnke, Thomas; Brossmann, Joachim; Walluscheck, Knut; Heller, Martin; Müller-Hülsbeck, Stefan

    2003-08-01

    To analyze the safety and effectiveness of a new monorail stent system for the treatment of failing femoropopliteal bypass grafts. Acute distal occlusions or stenoses of femoropopliteal bypass grafts were treated with balloon-expandable stents (13 or 18-mm diameter) pre-mounted on a monorail balloon catheter system. The delivery system was assessed subjectively for (1). compatibility with the sheath, (2). lesion crossing potential, (3). radiopacity, (4). flexibility of the catheter, (5). adequacy of stent expansion, and (5). balloon refolding. In 8 failing bypass grafts with distal lesions, the delivery system successfully deployed the stent at the desired location. Sheath compatibility, catheter flexibility, lesion crossing, and stent expansion were rated "excellent" by all examiners for the 18-mm device. Radiopacity of the mounted stent was graded "good" before and during positioning, but only "sufficient" following expansion. For this type of lesion, the investigators rated the overall performance of the device superior to conventional "over-the-wire" systems. The monorail balloon-expandable stent delivery system provides rapid introduction of the device over the guidewire, and its low profile facilitates the use of small sheaths to minimize access-site complications.

  4. Rapid prototyping of the Central Safety System for Nuclear Risk in ITER

    International Nuclear Information System (INIS)

    Scibile, L.; Ambrosino, G.; De Tommasi, G.; Pironti, A.

    2010-01-01

    The Central Safety System for Nuclear Risk (CSS-N) coordinates the safety control systems to ensure nuclear safety for the ITER complex. Since the CSS-N is a safety critical system, its validation and commissioning play a very important role; in particular the required level of reliability must be demonstrated. In such a scenario, it is strongly recommended to use modeling and simulation tools since the early design phase. Indeed, the modeling tools will help in the definition of the control system requirements. Furthermore the models can than be used for the rapid prototyping of the safety system. Hardware-in-the-loop simulations can also be performed in order to assess the performance of the control hardware against a plant simulator. The proposed approach relies on the availability of a plant simulator to develop the prototype of the control system. This paper introduces the methodology used to design and develop both the CSS-N Oriented Plant Simulator and the CSS-N Prototype.

  5. Rapid storage and retrieval of genomic intervals from a relational database system using nested containment lists.

    Science.gov (United States)

    Wiley, Laura K; Sivley, R Michael; Bush, William S

    2013-01-01

    Efficient storage and retrieval of genomic annotations based on range intervals is necessary, given the amount of data produced by next-generation sequencing studies. The indexing strategies of relational database systems (such as MySQL) greatly inhibit their use in genomic annotation tasks. This has led to the development of stand-alone applications that are dependent on flat-file libraries. In this work, we introduce MyNCList, an implementation of the NCList data structure within a MySQL database. MyNCList enables the storage, update and rapid retrieval of genomic annotations from the convenience of a relational database system. Range-based annotations of 1 million variants are retrieved in under a minute, making this approach feasible for whole-genome annotation tasks. Database URL: https://github.com/bushlab/mynclist.

  6. Driving a Bus in India: A Study of Indore Bus Rapid Transport System

    Directory of Open Access Journals (Sweden)

    Siddhartha K. RASTOGI

    2017-12-01

    Full Text Available Indore is a typical tier-2 town in the central province of India, fast becoming a regional commercial hub in an economically booming state. The city has a population of over 2 million with no significant public transport. Among the multiple options available, the city started implementing a dedicated corridor based Bus Rapid Transport System (BRTS. The project was jointly mooted by the central, state, and city authorities. However, the system encountered a range of problems, including conflicts and pulls between multiple implementing agencies, delays in delivery of hardware and constructions, land acquisition and compensation, vested interests, public interest litigations, and court orders. The paper analyses the BRTS, introduced in Indore in the midst of 2013, from multiple party perspectives with an underlying search for public policy and public management insights. The broad results indicate feasibility and desirability of the project; however, real problems emerge in public and public perception management.

  7. Mechanism-based model of a mass rapid transit system: A perspective

    Science.gov (United States)

    Legara, Erika Fille; Khoon, Lee Kee; Guang, Hung Gih; Monterola, Christopher

    2015-01-01

    In this paper, we discuss our findings on the spatiotemporal dynamics within the mass rapid transit (MRT) system of Singapore. We show that the trip distribution of Origin-Destination (OD) station pairs follows a power-law, implying the existence of critical OD pairs. We then present and discuss the empirically validated agent-based model (ABM) we have developed. The model allows recreation of the observed statistics and the setting up of various scenarios and their effects on the system, such as increasing the commuter population and the propagation of travel delays within the transportation network. The proposed model further enables identification of bottlenecks that can cause the MRT to break down, and consequently provide foresight on how such disruptions can possibly be managed. This can potentially provide a versatile approach for transport planners and government regulators to make quantifiable policies that optimally balance cost and convenience as a function of the number of the commuting public.

  8. The Impacts of the Mass Rapid Transit System on Household Car Ownership in Taipei

    Directory of Open Access Journals (Sweden)

    Wen-Hsiu Huang

    2014-06-01

    Full Text Available This paper investigates the impacts of Taipei Mass Rapid Transit (MRT system on household car ownership and analyses how socioeconomic characteristics affect household car ownership. We employ a difference-in-difference (DID strategy integrated with generalized Poisson regression models to examine the effects of MRT. The results are as follows: first, the establishment of Taipei MRT significantly reduced the level of household car ownership. Expanding the network of MRT system can be a feasible policy to control car ownership. Second, the levels of household car ownership are related to household’s socioeconomic characteristics. Third, households with high dependence on public transport own fewer cars after Taipei MRT began operation. Hence, the traffic authority should adopt more effective methods to encourage public transit use in order to decrease household car ownership.

  9. Flow-Based Systems for Rapid and High-Precision Enzyme Kinetics Studies

    Directory of Open Access Journals (Sweden)

    Supaporn Kradtap Hartwell

    2012-01-01

    Full Text Available Enzyme kinetics studies normally focus on the initial rate of enzymatic reaction. However, the manual operation of steps of the conventional enzyme kinetics method has some drawbacks. Errors can result from the imprecise time control and time necessary for manual changing the reaction cuvettes into and out of the detector. By using the automatic flow-based analytical systems, enzyme kinetics studies can be carried out at real-time initial rate avoiding the potential errors inherent in manual operation. Flow-based systems have been developed to provide rapid, low-volume, and high-precision analyses that effectively replace the many tedious and high volume requirements of conventional wet chemistry analyses. This article presents various arrangements of flow-based techniques and their potential use in future enzyme kinetics applications.

  10. Assessment of a potential rapid condensation induced water hammer in a passive auxiliary feedwater system

    Energy Technology Data Exchange (ETDEWEB)

    Jo, Jong Chull; Shin, Byung Soo; Do, Kyu Sik [Korea Institute of Nuclear Safety, Daejeon (Korea, Republic of); Moody, Frederick J. [General Electric (Retired), CA (United States)

    2012-10-15

    A passive auxiliary feedwater system (PAFS) which is incorporated in the APR+ system is a kind of closed natural circulation loop. The PAFS has no operating functions during normal plant operation, but it has a dedicated safety function of the residual heat removal following initiating events, including the unlikely event of the most limiting single failure occurring coincident with a loss of offsite power, when the feedwater system becomes inoperable or unavailable. Even in the unlikely event of a station blackout, the isolation valves can be opened either by DC power or manual operation and then the PAFS can also provide adequate condensate to the steam generator (SG). The PAFS piping in the vicinity of each of the two SGs is designed to minimize the potential for destructive water hammer during start up operation by setting the stroke time for full close or full open of the condensate isolation valves upon receipt of a passive auxiliary feedwater actuation signal. The temperature of the stagnant condensate water and its surrounding tubes and piping during the reactor normal operation modes may fall to the ambient temperature. A possible concern is the introduction of saturated steam into the PAFS recirculation pipe downstream of the PCHX in the beginning of the PAFS operation. Although the steam introduction rate is expected to be slow, a rapid condensation rate is expected due to the initial cold surrounding temperature in the pipe, which could result in a localized pressure reduction and the propagation of decompression and velocity disturbances into the condensate water leg, which might cause the sudden closure of check valves and associated water hammer. Thus, it is requisite for the licensing review of the PAFS design to confirm if destructive water hammers will not be produced due to such rapid condensation induced decompressions in the system. This paper addresses an assessment of the potential local decompressions which could result from the steam

  11. NIR responsive liposomal system for rapid release of drugs in cancer therapy

    Directory of Open Access Journals (Sweden)

    Chen MM

    2017-06-01

    Full Text Available Ming-Mao Chen,1 Yuan-Yuan Liu,1 Guang-Hao Su,2 Fei-Fei Song,1 Yan Liu,3 Qi-Qing Zhang1,4 1Institute of Biomedical and Pharmaceutical Technology, Fuzhou University, Fuzhou, 2Institute of Pediatric Research, Children’s Hospital of Soochow University, Suzhou, 3State Key Lab of Structural Chemistry, Fujian Institute of Research on the Structure of Matter, Chinese Academy of Sciences, Fuzhou, 4Key Laboratory of Biomedical Material of Tianjin, Institute of Biomedical Engineering, Chinese Academy of Medical Science & Peking Union Medical College, Tianjin, People’s Republic of China Abstract: To design a rapid release liposomal system for cancer therapy, a NIR responsive bubble-generating thermosensitive liposome (BTSL system combined with photothermal agent (Cypate, doxorubicin (DOX, and NH4HCO3 was developed. Cypate/DOX-BTSL exhibited a good aqueous stability, photostability, and photothermal effect. In vitro release suggested that the amounts of DOX released from BTSL were obviously higher than that of (NH42SO4 liposomes at 42°C. After NIR irradiation, the hyperthermic temperature induced by Cypate led to the decomposition of NH4HCO3 and the generation of a large number of CO2 bubbles, triggering a rapid release of drugs. Confocal laser scanning microscope and acridine orange staining indicated that Cypate/DOX-BTSL upon irradiation could facilitate to disrupt the lysosomal membranes and realize endolysosomal escape into cytosol, improving the intracellular uptake of DOX clearly. MTT and trypan blue staining implied that the cell damage of Cypate/DOX-BTSL with NIR irradiation was more severe than that in the groups without irradiation. In vivo results indicated that Cypate/DOX-BTSL with irradiation could dramatically increase the accumulation of DOX in tumor, inhibit tumor growth, and reduce systemic side effects of DOX. These data demonstrated that Cypate/DOX-BTSL has the potential to be used as a NIR responsive liposomal system for a rapid

  12. A Comprehensive Systems Testing Plan for the Smart Phone Assisted Rapid Communication and Control System (SPARCCS)

    Science.gov (United States)

    2012-09-01

    process. Interface faults can disrupt the functionality of a system ( Pressman , 2010). Interface faults can include: 1. Incorrect interrupt...and software instrumentation for full effectiveness ( Pressman , 2010). In SPARCCS testing, performance testing will be at the forefront of all test...which it is designed to operate. Deployment testing tests the following ( Pressman , 2010): 1. Installation procedures 2. Installation

  13. A rapid in vitro screening system for the identification and evaluation of anticancer drugs

    International Nuclear Information System (INIS)

    Kao, J.W.; Collins, J.L.

    1989-01-01

    We report the development of an in vitro screening system that can be used to identify new anticancer drugs that are specifically cytotoxic for dividing cells. The screening system takes advantage of the potential of many cell lines, including tumor cells, to stop dividing when they are plated at high cell density. The cytotoxic effects of anticancer drugs on dividing (i.e., cells plated at low cell density) and nondividing cells (i.e., cells plated at high cell density) is measured by the incorporation of 51Cr. This in vitro system was evaluated by measuring the cytotoxic effects of the anticancer drugs cisplatin, thiotepa, doxorubicin, methotrexate, and vinblastine on the cell lines B/C-N, ME-180, and MCF-7. In this in vitro system the concentrations of the anticancer drugs that produced significant cytotoxicity on only dividing cells are similar to the concentrations that are used clinically. The fact that this in vitro system is rapid, simple, applicable to many cell types, and able to predict effective concentrations of anticancer drugs should make it useful for the screening of new anticancer drugs and for the design of preclinical studies

  14. Condition Help: A Patient- and Family-Initiated Rapid Response System.

    Science.gov (United States)

    Eden, Elizabeth L; Rack, Laurie L; Chen, Ling-Wan; Bump, Gregory M

    2017-03-01

    Rapid response teams (RRTs) help in delivering safe, timely care. Typically they are activated by clinicians using specific parameters. Allowing patients and families to activate RRTs is a novel intervention. The University of Pittsburgh Medical Center developed and implemented a patient- and family-initiated rapid response system called Condition Help (CH). When the CH system is activated, a patient care liaison or an on-duty administrator meets bedside with the unit charge nurse to address the patient's concerns. In this study, we collected demographic data, call reasons, call designations (safety or nonsafety), and outcome information for all CH calls made during the period January 2012 through June 2015. Two hundred forty patients/family members made 367 CH calls during the study period. Most calls were made by patients (76.8%) rather than family members (21.8%). Of the 240 patients, 43 (18%) made multiple calls; their calls accounted for 46.3% of all calls (170/367). Inadequate pain control was the reason for the call in most cases (48.2%), followed by dissatisfaction with staff (12.5%). The majority of calls involved nonsafety issues (83.4%) rather than safety issues (11.4%). In 41.4% of cases, a change in care was made. Patient- and family-initiated RRTs are designed to engage patients and families in providing safer care. In the CH system, safety issues are identified, but the majority of calls involve nonsafety issues. Journal of Hospital Medicine 2017;12:157-161. © 2017 Society of Hospital Medicine

  15. Rapid Surface Sampling and Archival Record (RSSAR) System. Topical report, October 1, 1993--December 31, 1994

    International Nuclear Information System (INIS)

    1997-01-01

    This report describes the results of Phase 1 efforts to develop a Rapid Surface Sampling and Archival Record (RSSAR) System for the detection of semivolatile organic contaminants on concrete, transite, and metal surfaces. The characterization of equipment and building surfaces for the presence of contaminants as part of building decontamination and decommissioning activities is an immensely large tacks of concern to both government and industry. Contaminated and clean materials must be clearly identified and segregated so that the clean materials can be recycled or reused, if possible, or disposed of more cheaply as nonhazardous waste. Characterization of building and equipment surfaces will be needed during initial investigations, during cleanup operations, and during the final confirmatory process, increasing the total number of samples well beyond that needed for initial characterization. This multiplicity of information places a premium on the ability to handle and track data as efficiently as possible. Aware of the shortcomings of traditional surface characterization technology, GE, with DOE support has undertaken a 12-month effort to complete Phase 1 of a proposed four-phase program to develop the RSSAR system. The objectives of this work are to provide instrumentation to cost-effectively sample concrete and steel surfaces, provide a quick-look indication for the presence or absence of contaminants, and collect samples for later, more detailed analysis in a readily accessible and addressable form. The Rapid Surface Sampling and Archival Record (RSSAR) System will be a modular instrument made up of several components: (1) sampling heads for concrete surfaces, steel surfaces, and bulk samples; (2) quick-look detectors for photoionization and ultraviolet; (3) multisample trapping module to trap and store vaporized contaminants in a manner suitable for subsequent detailed lab-based analyses

  16. HB&L System: rapid determination of antibiotic sensitivity of bacteria isolated from blood cultures.

    Directory of Open Access Journals (Sweden)

    Simone Barocci

    2010-03-01

    Full Text Available Introduction. Blood culture is an important method to detect microbial pathogens on blood, very useful for diagnosing bacterial infections. Unfortunately, classical diagnostic protocols cannot directly identify bacteria responsible for sepsis and accordingly their antimicrobial profiles. This problem causes a delay of almost two days in the availability of a specific antimicrobial profile. Objective. Among the main causes of death, sepsis have a relevant importance. For this reason it is important both to identify pathogens and to perform an antimicrobial susceptibility test in the shortest time as possible. For this purpose, the main aim of this study is the evaluation of the performances of an antimicrobial susceptibility determination directly performed on positive blood cultures. Materials and methods. This study has been performed on 70 positive blood cultures, during the period from January to July 2009. A number of 35 blood cultures were positive for Gram negative bacteria, and 35 were positive for Gram positive bacteria. From these positive blood cultures, after a short sample preparation, it has been possible to directly determine antimicrobial susceptibility profiles by using the HB&L (formerly URO-QUICK instrument. Results. The HB&L system results showed a very good correlation with both the classical disk diffusion method and VITEK 2 automatic system.The performances between the methods carried out in this study were equivalent. Conclusions. From data reported, thanks to the rapidity and simplicity of the method used, we can assert that the direct susceptibility test available with the HB&L system, is useful for a rapid and early choice of the antibiotic treatment.

  17. Optimization of an on-board imaging system for extremely rapid radiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Cherry Kemmerling, Erica M.; Wu, Meng, E-mail: mengwu@stanford.edu; Yang, He; Fahrig, Rebecca [Department of Radiology, Stanford University, Stanford, California 94305 (United States); Maxim, Peter G.; Loo, Billy W. [Department of Radiation Oncology, Stanford University, Stanford, California 94305 and Stanford Cancer Institute, Stanford University School of Medicine, Stanford, California 94305 (United States)

    2015-11-15

    Purpose: Next-generation extremely rapid radiation therapy systems could mitigate the need for motion management, improve patient comfort during the treatment, and increase patient throughput for cost effectiveness. Such systems require an on-board imaging system that is competitively priced, fast, and of sufficiently high quality to allow good registration between the image taken on the day of treatment and the image taken the day of treatment planning. In this study, three different detectors for a custom on-board CT system were investigated to select the best design for integration with an extremely rapid radiation therapy system. Methods: Three different CT detectors are proposed: low-resolution (all 4 × 4 mm pixels), medium-resolution (a combination of 4 × 4 mm pixels and 2 × 2 mm pixels), and high-resolution (all 1 × 1 mm pixels). An in-house program was used to generate projection images of a numerical anthropomorphic phantom and to reconstruct the projections into CT datasets, henceforth called “realistic” images. Scatter was calculated using a separate Monte Carlo simulation, and the model included an antiscatter grid and bowtie filter. Diagnostic-quality images of the phantom were generated to represent the patient scan at the time of treatment planning. Commercial deformable registration software was used to register the diagnostic-quality scan to images produced by the various on-board detector configurations. The deformation fields were compared against a “gold standard” deformation field generated by registering initial and deformed images of the numerical phantoms that were used to make the diagnostic and treatment-day images. Registrations of on-board imaging system data were judged by the amount their deformation fields differed from the corresponding gold standard deformation fields—the smaller the difference, the better the system. To evaluate the registrations, the pointwise distance between gold standard and realistic registration

  18. Optimization of an on-board imaging system for extremely rapid radiation therapy

    International Nuclear Information System (INIS)

    Cherry Kemmerling, Erica M.; Wu, Meng; Yang, He; Fahrig, Rebecca; Maxim, Peter G.; Loo, Billy W.

    2015-01-01

    Purpose: Next-generation extremely rapid radiation therapy systems could mitigate the need for motion management, improve patient comfort during the treatment, and increase patient throughput for cost effectiveness. Such systems require an on-board imaging system that is competitively priced, fast, and of sufficiently high quality to allow good registration between the image taken on the day of treatment and the image taken the day of treatment planning. In this study, three different detectors for a custom on-board CT system were investigated to select the best design for integration with an extremely rapid radiation therapy system. Methods: Three different CT detectors are proposed: low-resolution (all 4 × 4 mm pixels), medium-resolution (a combination of 4 × 4 mm pixels and 2 × 2 mm pixels), and high-resolution (all 1 × 1 mm pixels). An in-house program was used to generate projection images of a numerical anthropomorphic phantom and to reconstruct the projections into CT datasets, henceforth called “realistic” images. Scatter was calculated using a separate Monte Carlo simulation, and the model included an antiscatter grid and bowtie filter. Diagnostic-quality images of the phantom were generated to represent the patient scan at the time of treatment planning. Commercial deformable registration software was used to register the diagnostic-quality scan to images produced by the various on-board detector configurations. The deformation fields were compared against a “gold standard” deformation field generated by registering initial and deformed images of the numerical phantoms that were used to make the diagnostic and treatment-day images. Registrations of on-board imaging system data were judged by the amount their deformation fields differed from the corresponding gold standard deformation fields—the smaller the difference, the better the system. To evaluate the registrations, the pointwise distance between gold standard and realistic registration

  19. 49 CFR 37.79 - Purchase or lease of new rail vehicles by public entities operating rapid or light rail systems.

    Science.gov (United States)

    2010-10-01

    ... entities operating rapid or light rail systems. 37.79 Section 37.79 Transportation Office of the Secretary... operating rapid or light rail systems. Each public entity operating a rapid or light rail system making a... system shall ensure that the vehicle is readily accessible to and usable by individuals with disabilities...

  20. Impact of rapid condensations of large vapor spaces on natural circulation in integral systems

    International Nuclear Information System (INIS)

    Wang, Z.; Almenas, K.; DiMarzo, M.; Hsu, Y.Y.; Unal, C.

    1992-01-01

    In this study we demonstrated that the Interruption-Resumption flow mode (IRM) observed in the University of Maryland 2x4 loop is a unique and effective natural circulation cooling mode. The IRM flow mode consists of a series of large flow cycles which are initiated from a quiescent steady-state flow condition by periodic rapid condensation of large vapor spaces. The significance of this mass/energy transport mechanism is that it cannot be evaluated using the techniques developed for the commonly known density-driven natural circulation cooling mode. We also demonstrated that the rapid condensation mechanism essentially acts as a strong amplifier which will augment small perturbations and will activate several flow phenomena. The interplay of the phenomena involves a degree of randomness. This poses two important implications. First, the study of an isolated flow phenomenon is not sufficient for the understanding of the system-wide IRM fluid movement. Second, the duplication of reactor transients which involves randomness can be achieved only within certain bounds. The modeling of such transients by deterministic computer codes requires recognition of this physical reality. (orig.)

  1. Groundwater flow system under a rapidly urbanizing coastal city as determined by hydrogeochemistry

    Science.gov (United States)

    Kagabu, Makoto; Shimada, Jun; Delinom, Robert; Tsujimura, Maki; Taniguchi, Makoto

    2011-01-01

    In the Jakarta area (Indonesia), excessive groundwater pumping due to the rapidly increasing population has caused groundwater-related problems such as brackish water contamination in coastal areas and land subsidence. In this study, we adopted multiple hydrogeochemical techniques to demonstrate the groundwater flow system in the Jakarta area. Although almost all groundwater existing in the Jakarta basin is recharged at similar elevations, the water quality and residence time demonstrates a clear difference between the shallow and deep aquifers. Due to the rapid decrease in the groundwater potential in urban areas, we found that the seawater intrusion and the shallow and deep groundwaters are mixing, a conclusion confirmed by major ions, Br -:Cl - ratios, and chlorofluorocarbon (CFC)-12 analysis. Spring water and groundwater samples collected from the southern mountainside area show younger age characteristics with high concentrations of 14C and Ca-HCO 3 type water chemistry. We estimated the residence times of these groundwaters within 45 years under piston flow conditions by tritium analysis. Also, these groundwater ages can be limited to 20-30 years with piston flow evaluated by CFCs. Moreover, due to the magnitude of the CFC-12 concentration, we can use a pseudo age indicator in this field study, because we found a positive correlation between the major type of water chemistry and the CFC-12 concentration.

  2. Development of a rapid "fingerprinting" system for wine authenticity by mid-infrared spectroscopy.

    Science.gov (United States)

    Bevin, Christopher J; Fergusson, Allison J; Perry, Wade B; Janik, Leslie J; Cozzolino, Daniel

    2006-12-27

    This paper reports on the development of a rapid and simple method for red wine authenticity confirmation during transport and processing; namely, a wine "fingerprinting" system. When wine is transported between two sites, a sample is taken and a mid-infrared (MIR) spectrum is obtained. One hundred sixty-one (n = 161) samples of three main red wine varieties grown in Australia, Shiraz, Cabernet Sauvignon, and Merlot, were collected from six commercial wineries across Australia and scanned in transmission on two MIR spectrophotometers located at The Hardy Wine Company's main site at Reynella, South Australia (Foss WineScan FT 120) (926-5012 cm-1). A similarity index (SI) method was used as a tool to classify wine samples on the basis of their spectral data. The results showed that high rates of classification were obtained when wine samples scanned in different instruments were analyzed. The SI has been proven to provide an acceptable measurement for authentication of red wine integrity during transportation. In five of the six winery data sets, the SI correctly classified 98% of the wines. It was also observed that less than 1% of wines were misclassified between the different wineries investigated. Further studies are needed in order to test the applicability of the SI in a commercial situation and to evaluate its potential as a rapid quality control tool for routine use to authenticate wine samples during transport.

  3. A miniaturized optoelectronic system for rapid quantitative label-free detection of harmful species in food

    Science.gov (United States)

    Raptis, Ioannis; Misiakos, Konstantinos; Makarona, Eleni; Salapatas, Alexandros; Petrou, Panagiota; Kakabakos, Sotirios; Botsialas, Athanasios; Jobst, Gerhard; Haasnoot, Willem; Fernandez-Alba, Amadeo; Lees, Michelle; Valamontes, Evangelos

    2016-03-01

    Optical biosensors have emerged in the past decade as the most promising candidates for portable, highly-sensitive bioanalytical systems that can be employed for in-situ measurements. In this work, a miniaturized optoelectronic system for rapid, quantitative, label-free detection of harmful species in food is presented. The proposed system has four distinctive features that can render to a powerful tool for the next generation of Point-of-Need applications, namely it accommodates the light sources and ten interferometric biosensors on a single silicon chip of a less-than-40mm2 footprint, each sensor can be individually functionalized for a specific target analyte, the encapsulation can be performed at the wafer-scale, and finally it exploits a new operation principle, Broad-band Mach-Zehnder Interferometry to ameliorate its analytical capabilities. Multi-analyte evaluation schemes for the simultaneous detection of harmful contaminants, such as mycotoxins, allergens and pesticides, proved that the proposed system is capable of detecting within short time these substances at concentrations below the limits imposed by regulatory authorities, rendering it to a novel tool for the near-future food safety applications.

  4. A STUDY ON THE INTRODUCTION OF BUS RAPID TRANSIT SYSTEM IN ASIAN DEVELOPING CITIES

    Directory of Open Access Journals (Sweden)

    Thaned SATIENNAM

    2006-01-01

    Full Text Available Bus Rapid Transit (BRT has increasingly become an attractive urban transit alternative in many Asian developing cities due to its cost-effective and flexible implementation. However, it still seems to be difficult to introduce BRT to these cities because almost all of their city structures have been developed under solely a road transport development city plan and weakness of land use control gives rise to many problems, such as urban sprawl, traffic congestion, and air pollution. The purpose of this study was to introduce several strategies to support BRT implementation in Asian developing cities, such as a strategy to appropriately integrate the paratransit system into BRT system as being a feeder along a BRT corridor to supply demand. These proposed strategies were evaluated by applying demand forecasting and emission models to the BRT project plan of Bangkok Metropolitan Administration (BMA in Thailand. It was demonstrated that the proposed strategies could effectively improve the BRT ridership, traffic conditions, and air pollution emission of the entire system in Bangkok. This study could be further extended to include strategy recommendation if a BRT system were to be introduced to other Asian developing cities.

  5. Rapid wave and storm surge warning system for tropical cyclones in Mexico

    Science.gov (United States)

    Appendini, C. M.; Rosengaus, M.; Meza, R.; Camacho, V.

    2015-12-01

    The National Hurricane Center (NHC) in Miami, is responsible for the forecast of tropical cyclones in the North Atlantic and Eastern North Pacific basins. As such, Mexico, Central America and Caribbean countries depend on the information issued by the NHC related to the characteristics of a particular tropical cyclone and associated watch and warning areas. Despite waves and storm surge are important hazards for marine operations and coastal dwellings, their forecast is not part of the NHC responsibilities. This work presents a rapid wave and storm surge warning system based on 3100 synthetic tropical cyclones doing landfall in Mexico. Hydrodynamic and wave models were driven by the synthetic events to create a robust database composed of maximum envelops of wind speed, significant wave height and storm surge for each event. The results were incorporated into a forecast system that uses the NHC advisory to locate the synthetic events passing inside specified radiuses for the present and forecast position of the real event. Using limited computer resources, the system displays the information meeting the search criteria, and the forecaster can select specific events to generate the desired hazard map (i.e. wind, waves, and storm surge) based on the maximum envelop maps. This system was developed in a limited time frame to be operational in 2015 by the National Hurricane and Severe Storms Unit of the Mexican National Weather Service, and represents a pilot project for other countries in the region not covered by detailed storm surge and waves forecasts.

  6. Rapidly destructive arthrosis of the hip joint in a young adult with systemic lupus erythematosus.

    Science.gov (United States)

    Lee, Yongseung; Motomura, Goro; Yamamoto, Takuaki; Nakashima, Yasuharu; Ohishi, Masanobu; Hamai, Satoshi; Iura, Kunio; Iwamoto, Yukihide

    2015-10-01

    A 37-year-old female had been treated with corticosteroids for systemic lupus erythematosus clinically diagnosed at age 10. She suddenly had right hip pain without any antecedent trauma. Four months after the onset of pain, she visited her primary care physician. On magnetic resonance imaging, joint space narrowing at the weight-bearing area was already seen with bone marrow edematous lesions in both the femoral head and acetabulum. She was treated non-operatively; however, her pain continued to worsen in severity. Thirteen months after the onset of pain, she was referred to our hospital. A plain radiograph showed subluxation of the collapsed femoral head accompanied by destruction of the acetabular rim. Because of her severe intractable pain, she underwent total hip arthroplasty 1 month after her first visit. Histological examination of the resected femoral head revealed pseudogranulomatous lesions along with prominent callus formation, suggesting rapid destruction of the femoral head.

  7. Rapid and Sensitive Determination of Lipid Oxidation Using the Reagent Kit Based on Spectrophotometry (FOODLABfat System

    Directory of Open Access Journals (Sweden)

    Chang Woo Kwon

    2016-01-01

    Full Text Available The reliability and availability of FOODLABfat system for determining acid value (AV and peroxide value (POV were assessed during the hydrolytic rancidification and lipid oxidation of edible oils. This reagent kit based on spectrophotometry was compared to the official methods (ISO 660 and 3960 protocols based on manual titration employing the standard mixture for the simulated oxidation models and edible oils during the thermally induced oxidation at 180°C. The linear regression line of standard mixture and the significant difference of thermally oxidized time course study determined between them showed high correlations (R2=0.998 and p<0.05 in both AVs and POVs. Considering ISO protocols with a probability of human error in manual titration, the rapidness and simplicity of the reagent kit based on spectrophotometry make it a promising alternative to monitor the lipid oxidation of edible oils and lipid-containing foods.

  8. Visual processing in rapid-chase systems: Image processing, attention, and awareness

    Directory of Open Access Journals (Sweden)

    Thomas eSchmidt

    2011-07-01

    Full Text Available Visual stimuli can be classified so rapidly that their analysis may be based on a single sweep of feedforward processing through the visuomotor system. Behavioral criteria for feedforward processing can be evaluated in response priming tasks where speeded pointing or keypress responses are performed towards target stimuli which are preceded by prime stimuli. We apply this method to several classes of complex stimuli. 1 When participants classify natural images into animals or non-animals, the time course of their pointing responses indicates that prime and target signals remain strictly sequential throughout all processing stages, meeting stringent behavioral criteria for feedforward processing (rapid-chase criteria. 2 Such priming effects are boosted by selective visual attention for positions, shapes, and colors, in a way consistent with bottom-up enhancement of visuomotor processing, even when primes cannot be consciously identified. 3 Speeded processing of phobic images is observed in participants specifically fearful of spiders or snakes, suggesting enhancement of feedforward processing by long-term perceptual learning. 4 When the perceived brightness of primes in complex displays is altered by means of illumination or transparency illusions, priming effects in speeded keypress responses can systematically contradict subjective brightness judgments, such that one prime appears brighter than the other but activates motor responses as if it was darker. We propose that response priming captures the output of the first feedforward pass of visual signals through the visuomotor system, and that this output lacks some characteristic features of more elaborate, recurrent processing. This way, visuomotor measures may become dissociated from several aspects of conscious vision. We argue that "fast" visuomotor measures predominantly driven by feedforward processing should supplement "slow" psychophysical measures predominantly based on visual

  9. Rapid enumeration of low numbers of moulds in tea based drinks using an automated system.

    Science.gov (United States)

    Tanaka, Kouichi; Yamaguchi, Nobuyasu; Baba, Takashi; Amano, Norihide; Nasu, Masao

    2011-01-31

    Aseptically prepared cold drinks based on tea have become popular worldwide. Contamination of these drinks with harmful microbes is a potential health problem because such drinks are kept free from preservatives to maximize aroma and flavour. Heat-tolerant conidia and ascospores of fungi can survive pasteurization, and need to be detected as quickly as possible. We were able to rapidly and accurately detect low numbers of conidia and ascospores in tea-based drinks using fluorescent staining followed by an automated counting system. Conidia or ascospores were inoculated into green tea and oolong tea, and samples were immediately filtered through nitrocellulose membranes (pore size: 0.8 μm) to concentrate fungal propagules. These were transferred onto potato dextrose agar and incubated for 23 h at 28 °C. Fungi germinating on the membranes were fluorescently stained for 30 min. The stained mycelia were counted selectively within 90s using an automated counting system (MGS-10LD; Chuo Electric Works, Osaka, Japan). Very low numbers (1 CFU/100ml) of conidia or ascospores could be rapidly counted, in contrast to traditional labour intensive techniques. All tested mould strains were detected within 24h while conventional plate counting required 72 h for colony enumeration. Counts of slow-growing fungi (Cladosporium cladosporioides) obtained by automated counting and by conventional plate counting were close (r(2) = 0.986). Our combination of methods enables counting of both fast- and slow-growing fungi, and should be useful for microbiological quality control of tea-based and also other drinks. Copyright © 2011 Elsevier B.V. All rights reserved.

  10. A Portable Impedance Immunosensing System for Rapid Detection of Salmonella Typhimurium.

    Science.gov (United States)

    Wen, Tao; Wang, Ronghui; Sotero, America; Li, Yanbin

    2017-08-28

    Salmonella Typhimurium is one of the most dangerous foodborne pathogens and poses a significant threat to human health. The objective of this study was to develop a portable impedance immunosensing system for rapid and sensitive detection of S . Typhimurium in poultry. The developed portable impedance immunosensing system consisted of a gold interdigitated array microelectrode (IDAM), a signal acquisitive interface and a laptop computer with LabVIEW software. The IDAM was first functionalized with 16-Mercaptohexadecanoic acid, and streptavidin was immobilized onto the electrode surface through covalent bonding. Then, biotin-labelled S . Typhimurium -antibody was immobilized onto the IDAM surface. Samples were dropped on the surface of the IDAM and the S . Typhimurium cells in the samples were captured by the antibody on the IDAM. This resulted in impedance changes that were measured and displayed with the LabVIEW software. An equivalent circuit of the immunosensor demonstrated that the largest change in impedance was due to the electron-transfer resistance. The equivalent circuit showed an increase of 35% for the electron-transfer resistance value compared to the negative control. The calibration result indicated that the portable impedance immunosensing system could be used to measure the standard impedance elements, and it had a maximum error of measurement of approximately 13%. For pure culture detection, the system had a linear relationship between the impedance change and the logarithmic value of S . Typhimurium cells ranging from 76 to 7.6 × 10⁶ CFU (colony-forming unit) (50 μL) -1 . The immunosensor also had a correlation coefficient of 0.98, and a high specificity for detection of S . Typhimurium cells with a limit of detection (LOD) of 10² CFU (50 μL) -1 . The detection time from the moment a sample was introduced to the display of the results was 1 h. To conclude, the portable impedance immunosensing system for detection of S . Typhimurium achieved

  11. A Portable Impedance Immunosensing System for Rapid Detection of Salmonella Typhimurium

    Directory of Open Access Journals (Sweden)

    Tao Wen

    2017-08-01

    Full Text Available Salmonella Typhimurium is one of the most dangerous foodborne pathogens and poses a significant threat to human health. The objective of this study was to develop a portable impedance immunosensing system for rapid and sensitive detection of S. Typhimurium in poultry. The developed portable impedance immunosensing system consisted of a gold interdigitated array microelectrode (IDAM, a signal acquisitive interface and a laptop computer with LabVIEW software. The IDAM was first functionalized with 16-Mercaptohexadecanoic acid, and streptavidin was immobilized onto the electrode surface through covalent bonding. Then, biotin-labelled S. Typhimurium-antibody was immobilized onto the IDAM surface. Samples were dropped on the surface of the IDAM and the S. Typhimurium cells in the samples were captured by the antibody on the IDAM. This resulted in impedance changes that were measured and displayed with the LabVIEW software. An equivalent circuit of the immunosensor demonstrated that the largest change in impedance was due to the electron-transfer resistance. The equivalent circuit showed an increase of 35% for the electron-transfer resistance value compared to the negative control. The calibration result indicated that the portable impedance immunosensing system could be used to measure the standard impedance elements, and it had a maximum error of measurement of approximately 13%. For pure culture detection, the system had a linear relationship between the impedance change and the logarithmic value of S. Typhimurium cells ranging from 76 to 7.6 × 106 CFU (colony-forming unit (50 μL−1. The immunosensor also had a correlation coefficient of 0.98, and a high specificity for detection of S. Typhimurium cells with a limit of detection (LOD of 102 CFU (50 μL−1. The detection time from the moment a sample was introduced to the display of the results was 1 h. To conclude, the portable impedance immunosensing system for detection of S. Typhimurium

  12. A hybrid thermal video and FTIR spectrometer system for rapidly locating and characterizing gas leaks

    Science.gov (United States)

    Williams, David J.; Wadsworth, Winthrop; Salvaggio, Carl; Messinger, David W.

    2006-08-01

    Undiscovered gas leaks, known as fugitive emissions, in chemical plants and refinery operations can impact regional air quality and present a loss of product for industry. Surveying a facility for potential gas leaks can be a daunting task. Industrial leak detection and repair programs can be expensive to administer. An efficient, accurate and cost effective method for detecting and quantifying gas leaks would both save industries money by identifying production losses and improve regional air quality. Specialized thermal video systems have proven effective in rapidly locating gas leaks. These systems, however, do not have the spectral resolution for compound identification. Passive FTIR spectrometers can be used for gas compound identification, but using these systems for facility surveys is problematic due to their small field of view. A hybrid approach has been developed that utilizes the thermal video system to locate gas plumes using real time visualization of the leaks, coupled with the high spectral resolution FTIR spectrometer for compound identification and quantification. The prototype hybrid video/spectrometer system uses a sterling cooled thermal camera, operating in the MWIR (3-5 μm) with an additional notch filter set at around 3.4 μm, which allows for the visualization of gas compounds that absorb in this narrow spectral range, such as alkane hydrocarbons. This camera is positioned alongside of a portable, high speed passive FTIR spectrometer, which has a spectral range of 2 - 25 μm and operates at 4 cm -1 resolution. This system uses a 10 cm telescope foreoptic with an onboard blackbody for calibration. The two units are optically aligned using a turning mirror on the spectrometer's telescope with the video camera's output.

  13. Development and validation of a rapid test system for detection of pork meat and collagen residues.

    Science.gov (United States)

    Masiri, J; Benoit, L; Barrios-Lopez, B; Thienes, C; Meshgi, M; Agapov, A; Dobritsa, A; Nadala, C; Samadpour, M

    2016-11-01

    Mislabeling, contamination, and economic adulteration of meat products with undeclared pork tissues are illegal under regulations promulgated by numerous regulatory agencies. Nonetheless, analysis of the European meat industry has revealed pervasive meat adulteration, necessitating more extensive application of meat authentication testing. As existing methods for meat speciation require specialized equipment and/or training, we developed a detection system based on a lateral flow device (LFD) assay format capable of rapidly (~35min) identifying porcine residues derived from raw meat, cooked meat, and gelatin down to 0.01%, 1.0%, and 2.5% contamination, respectively. Specificity analysis revealed no cross-reactivity with meat derived from chicken, turkey, horse, beef, lamb, or goat. Comparison with a commercial ELISA kit and PCR method revealed similar if not improved sensitivity, with the added feature that the LFD-based system required considerably less time to perform. Accordingly, this test system should aid the food industry and food control authorities in monitoring for adulteration with pork. Copyright © 2016 Elsevier Ltd. All rights reserved.

  14. The design of rapid turbidity measurement system based on single photon detection techniques

    Science.gov (United States)

    Yang, Yixin; Wang, Huanqin; Cao, Yangyang; Gui, Huaqiao; Liu, Jianguo; Lu, Liang; Cao, Huibin; Yu, Tongzhu; You, Hui

    2015-10-01

    A new rapid turbidity measurement system has been developed to measure the turbidity of drinking water. To determinate the turbidity quantitatively, the total intensity of scattering light has been measured and quantified as number of photons by adopting the single photon detection techniques (SPDT) which has the advantage of high sensitivity. On the basis of SPDT, the measurement system has been built and series of experiments have been carried out. Combining then the 90° Mie scattering theory with the principle of SPDT, a turbidity measurement model has been proposed to explain the experimental results. The experimental results show that a turbidity, which is as low as 0.1 NTU (Nephelometric Turbidity Units), can be measured steadily within 100 ms. It also shows a good linearity and stability over the range of 0.1-400 NTU and the precision can be controlled within 5% full scale. In order to improve its precision and stability, some key parameters, including the sampling time and incident light intensity, have been discussed. It has been proved that, to guarantee an excellent system performance, a good compromise between the measurement speed and the low power consumption should be considered adequately depending on the practical applications.

  15. Feasibility of rapid ethical assessment for the Ethiopian health research ethics review system.

    Science.gov (United States)

    Addissie, Adamu; Davey, Gail; Newport, Melanie; Farsides, Bobbie; Feleke, Yeweyenhareg

    2015-01-01

    One of the challenges in the process of ethical medical research in developing countries, including Ethiopia, is translating universal principles of medical ethics into appropriate informed consent documents and their implementation. Rapid Ethical Assessment (REA) has been suggested as a feasible approach to meet this application gap. In the past few years REA has been employed in few research project in Ethiopia and have been found to be a useful and practical approach. Feasibility assessment of REA for the Ethiopian research setting was conducted between 2012-2013 in order to inform the subsequent introduction of REA into research ethics review and governance system in the country. REA was found to be an appropriate, relevant and feasible venture. We argue that REA can be integrated as part of the ethics review and governance system in Ethiopia. REA tools and techniques are considered relevant and acceptable to the Ethiopian research community, with few practical challenges anticipated in their implementation. REA are considered feasible for integration in the Ethiopian ethics review system.

  16. Design and performance of a 50mK rapid turnaround detector characterization system

    International Nuclear Information System (INIS)

    Benford, Dominic J.; Dipirro, Michael J.; Forgione, Joshua B.; Jackson, Michael L.; Harvey Moseley, S.; Panek, John; Shirron, Peter J.; Staguhn, Johannes G.

    2006-01-01

    Upcoming major NASA missions such as the Einstein Inflation Probe and the Single Aperture Far-Infrared Observatory will require arrays of detectors with thousands of background-limited elements sensitive to wavelengths from ∼50μm to ∼3mm. Because of the low power levels present in space with cryogenic telescopes, these detectors will likely operate at temperatures below 100mK. In order to make rapid progress on detector development, the cryogenic testing cycle must be made convenient and quick. We have developed a cryogenic detector characterization system capable of testing superconducting detector arrays in formats up to 8x32, read out by SQUID multiplexers. The system relies on the cooling of a two-stage adiabatic demagnetization refrigerator immersed in a liquid helium bath. This approach permits a detector to be cooled from 300K to 50mK in under 6h, so that a test cycle begun in the morning will be over by the end of the day. The system is modular, with two identical immersible units, so that while one unit is cooling, the second can be reconfigured for the next battery of tests

  17. A rapid response air quality analysis system for use in projects having stringent quality assurance requirements

    International Nuclear Information System (INIS)

    Bowman, A.W.

    1990-01-01

    This paper describes an approach to solve air quality problems which frequently occur during iterations of the baseline change process. From a schedule standpoint, it is desirable to perform this evaluation in as short a time as possible while budgetary pressures limit the size of the staff available to do the work. Without a method in place to deal with baseline change proposal requests the environment analysts may not be able to produce the analysis results in the time frame expected. Using a concept called the Rapid Response Air Quality Analysis System (RAAS), the problems of timing and cost become tractable. The system could be adapted to assess other atmospheric pathway impacts, e.g., acoustics or visibility. The air quality analysis system used to perform the EA analysis (EA) for the Salt Repository Project (part of the Civilian Radioactive Waste Management Program), and later to evaluate the consequences of proposed baseline changes, consists of three components: Emission source data files; Emission rates contained in spreadsheets; Impact assessment model codes. The spreadsheets contain user-written codes (macros) that calculate emission rates from (1) emission source data (e.g., numbers and locations of sources, detailed operating schedules, and source specifications including horsepower, load factor, and duty cycle); (2) emission factors such as those published by the U.S. Environmental Protection Agency, and (3) control efficiencies

  18. Rapid and Parallel Adaptive Evolution of the Visual System of Neotropical Midas Cichlid Fishes.

    Science.gov (United States)

    Torres-Dowdall, Julián; Pierotti, Michele E R; Härer, Andreas; Karagic, Nidal; Woltering, Joost M; Henning, Frederico; Elmer, Kathryn R; Meyer, Axel

    2017-10-01

    Midas cichlid fish are a Central American species flock containing 13 described species that has been dated to only a few thousand years old, a historical timescale infrequently associated with speciation. Their radiation involved the colonization of several clear water crater lakes from two turbid great lakes. Therefore, Midas cichlids have been subjected to widely varying photic conditions during their radiation. Being a primary signal relay for information from the environment to the organism, the visual system is under continuing selective pressure and a prime organ system for accumulating adaptive changes during speciation, particularly in the case of dramatic shifts in photic conditions. Here, we characterize the full visual system of Midas cichlids at organismal and genetic levels, to determine what types of adaptive changes evolved within the short time span of their radiation. We show that Midas cichlids have a diverse visual system with unexpectedly high intra- and interspecific variation in color vision sensitivity and lens transmittance. Midas cichlid populations in the clear crater lakes have convergently evolved visual sensitivities shifted toward shorter wavelengths compared with the ancestral populations from the turbid great lakes. This divergence in sensitivity is driven by changes in chromophore usage, differential opsin expression, opsin coexpression, and to a lesser degree by opsin coding sequence variation. The visual system of Midas cichlids has the evolutionary capacity to rapidly integrate multiple adaptations to changing light environments. Our data may indicate that, in early stages of divergence, changes in opsin regulation could precede changes in opsin coding sequence evolution. © The Author 2017. Published by Oxford University Press on behalf of the Society for Molecular Biology and Evolution. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  19. Dealing with the Empty Vehicle Movements in Personal Rapid Transit System with Batteries Constraints in a Dynamic Context

    Directory of Open Access Journals (Sweden)

    Ezzeddine Fatnassi

    2017-01-01

    Full Text Available The Personal Rapid Transit is a new emergent transportation tool. It relies on using a set of small driverless electric vehicles to transport people on demand. Because of the specific on-demand characteristic of the Personal Rapid Transit system, many Personal Rapid Transit vehicles would move empty which results in a high level of wasted transportation capacity. This is enhanced while using Personal Rapid Transit vehicles with limited electric battery capacity. This paper deals with this problem in a real time context while minimizing the set of empty vehicle movements. First, a mathematical formulation to benchmark waiting time of passengers in Personal Rapid Transit systems is proposed. Then, a simulation model that captures the main features of the Personal Rapid Transit system is developed. A decision support system which integrates several real time solution strategies as well as a simulation module is proposed. Our dispatching strategies are evaluated and compared based on our simulation model. The efficiency of our method is tested through extensive test studies.

  20. Effect of a Real-Time Electronic Dashboard on a Rapid Response System.

    Science.gov (United States)

    Fletcher, Grant S; Aaronson, Barry A; White, Andrew A; Julka, Reena

    2017-11-20

    A rapid response system (RRS) may have limited effectiveness when inpatient providers fail to recognize signs of early patient decompensation. We evaluated the impact of an electronic medical record (EMR)-based alerting dashboard on outcomes associated with RRS activation. We used a repeated treatment study in which the dashboard display was successively turned on and off each week for ten 2-week cycles over a 20-week period on the inpatient acute care wards of an academic medical center. The Rapid Response Team (RRT) dashboard displayed all hospital patients in a single view ranked by severity score, updated in real time. The dashboard could be seen within the EMR by any provider, including RRT members. The primary outcomes were the incidence rate ratio (IRR) of all RRT activations, unexpected ICU transfers, cardiopulmonary arrests and deaths on general medical-surgical wards (wards). We conducted an exploratory analysis of first RRT activations. There were 6736 eligible admissions during the 20-week study period. There was no change in overall RRT activations (IRR = 1.14, p = 0.07), but a significant increase in first RRT activations (IRR = 1.20, p = 0.04). There were no significant differences in unexpected ICU transfers (IRR = 1.15, p = 0.25), cardiopulmonary arrests on general wards (IRR = 1.46, p = 0.43), or deaths on general wards (IRR = 0.96, p = 0.89). The introduction of the RRT dashboard was associated with increased initial RRT activations but not overall activations, unexpected ICU transfers, cardiopulmonary arrests, or death. The RRT dashboard is a novel tool to help providers recognize patient decompensation and may improve initial RRT notification.

  1. TOWARD INDONESIAN TSUNAMI EARLY WARNING SYSTEM BY USING RAPID RUPTURE DURATIONS CALCULATION

    Directory of Open Access Journals (Sweden)

    M. Adlazim

    2011-01-01

    Full Text Available Indonesia has an Indonesian Tsunami Early Warning System (Ina-TEWS since 2008. The Ina-TEWS has used automatic processing on hypocenter; Mwp, Mw (mB and Mj. If earthquake occurred in Ocean, depth 7, then Ina-TEWS announce early warning that the earthquake can generate tsunami. However, the announcement of the Ina-TEWS is still not accuracy. Purpose of this study is to estimate earthquake rupture duration of large Indonesia earthquakes that occurred in Indian Ocean, Java, Timor Sea, Banda Sea, Arafura Sea and Pacific Ocean using a direct procedure and software developed Lomax and Michelini for rapid assessment of earthquake tsunami potential by deriving two simple measures from vertical component broadband P-wave velocity record. The first is the high-frequency apparent rupture duration, Tdur which may be related to can be related to the critical parameters rupture length (L, depth (z, and shear modulus (μ. The second is a confirmation of the earlier finding by Lomax and Michelini, namely that the rupture duration has a stronger influence to generate tsunami than Mw and Depth. We analyzed at least 510 vertical seismogram recorded by GEOFON-IA and IRIS-DMC networks. Our analysis shows that the seismic potency, LWD, which is more obviously related to capability to generate a tsunami than former. The larger Tdur the larger is the seismic potency LWD because Tdur is proportional to L/vr (with vr – rupture velocity. We also suggest that tsunami potential is not directly related to the faulting type of source and for events that have rupture duration greater than 50 s, the earthquakes generated tsunami. With available real-time seismogram data, rapid calculation, rupture duration discriminant can be completed within 3 to 8 min after the P-onset.

  2. Rapid learning in practice: A lung cancer survival decision support system in routine patient care data

    International Nuclear Information System (INIS)

    Dekker, Andre; Vinod, Shalini; Holloway, Lois; Oberije, Cary; George, Armia; Goozee, Gary; Delaney, Geoff P.; Lambin, Philippe; Thwaites, David

    2014-01-01

    Background and purpose: A rapid learning approach has been proposed to extract and apply knowledge from routine care data rather than solely relying on clinical trial evidence. To validate this in practice we deployed a previously developed decision support system (DSS) in a typical, busy clinic for non-small cell lung cancer (NSCLC) patients. Material and methods: Gender, age, performance status, lung function, lymph node status, tumor volume and survival were extracted without review from clinical data sources for lung cancer patients. With these data the DSS was tested to predict overall survival. Results: 3919 lung cancer patients were identified with 159 eligible for inclusion, due to ineligible histology or stage, non-radical dose, missing tumor volume or survival. The DSS successfully identified a good prognosis group and a medium/poor prognosis group (2 year OS 69% vs. 27/30%, p < 0.001). Stage was less discriminatory (2 year OS 47% for stage I–II vs. 36% for stage IIIA–IIIB, p = 0.12) with most good prognosis patients having higher stage disease. The DSS predicted a large absolute overall survival benefit (∼40%) for a radical dose compared to a non-radical dose in patients with a good prognosis, while no survival benefit of radical radiotherapy was predicted for patients with a poor prognosis. Conclusions: A rapid learning environment is possible with the quality of clinical data sufficient to validate a DSS. It uses patient and tumor features to identify prognostic groups in whom therapy can be individualized based on predicted outcomes. Especially the survival benefit of a radical versus non-radical dose predicted by the DSS for various prognostic groups has clinical relevance, but needs to be prospectively validated

  3. The WMO/IAEA rapid data exchange system in support of the early notification convention

    International Nuclear Information System (INIS)

    Asculai, E.; Mildner, S.

    1990-01-01

    Following the adoption, in September 1986, of the Convention on Early Notification of a Nuclear Accident, the IAEA and the WMO began work on the development of a methodology for the rapid dissemination of information and data following a nuclear accident. Expert Group meetings defined the data and information which needs to be disseminated, under the requirements of the Conventions. The Global Telecommunication System (GTS) of the WMO was identified as the suitable technical means of transmission since it combines immediate availability during times of emergency, rapidity of transmission and permanent connections to all Member States through their National Meteorological Centres. In order to utilize the GTS, special procedures and transmission formats have to be observed ad a specific code was jointly developed by WMO and IAEA to make the message Language-independent. Relevant instructions were issued in the WMO/IAEA Manual on the use of the WMO-GTS for the Early Notification Conventions. National arrangements for access by competent authorities to the information provided under the Early Notification Convention and for the provision of basic radiological data are of critical importance. Preparations are being made to provide specialized analyses and predictions on the atmospheric transport of radionuclides using the GTS and other means. The format and number of special output products is being specified in accordance with the requirements of the Member States. Requirements for meteorological and radiological data need to be kept under review in the light of model developments. The IAEA is presently engaged in the production of a software package for the coding/decoding of the data transmission

  4. Noninvasive optoacoustic system for rapid diagnosis and management of circulatory shock

    Science.gov (United States)

    Petrov, Irene Y.; Kinsky, Michael; Petrov, Yuriy; Petrov, Andrey; Henkel, S. N.; Seeton, Roger; Esenaliev, Rinat O.; Prough, Donald S.

    2013-03-01

    Circulatory shock can lead to death or severe complications, if not promptly diagnosed and effectively treated. Typically, diagnosis and management of circulatory shock are guided by blood pressure and heart rate. However, these variables have poor specificity, sensitivity, and predictive value. Early goal-directed therapy in septic shock patients, using central venous catheterization (CVC), reduced mortality from 46.5% to 30%. However, CVC is invasive and complication-prone. We proposed to use an optoacoustic technique for noninvasive, rapid assessment of peripheral and central venous oxygenation. In this work we used a medical grade optoacoustic system for noninvasive, ultrasound image-guided measurement of central and peripheral venous oxygenation. Venous oxygenation during shock declines more rapidly in the periphery than centrally. Ultrasound imaging of the axillary [peripheral] and internal jugular vein [central] was performed using the Vivid e (GE Healthcare). We built an optoacoustic interface incorporating an optoacoustic transducer and a standard ultrasound imaging probe. Central and peripheral venous oxygenations were measured continuously in healthy volunteers. To simulate shock-induced changes in central and peripheral oxygenation, we induced peripheral vasoconstriction in the upper extremity by using a cooling blanket. Central and peripheral venous oxygenations were measured before (baseline) and after cooling and after rewarming. During the entire experiment, central venous oxygenation was relatively stable, while peripheral venous oxygenation decreased by 5-10% due to cooling and recovered after rewarming. The obtained data indicate that noninvasive, optoacoustic measurements of central and peripheral venous oxygenation may be used for diagnosis and management of circulatory shock with high sensitivity and specificity.

  5. Health Systems Research in a Complex and Rapidly Changing Context: Ethical Implications of Major Health Systems Change at Scale.

    Science.gov (United States)

    MacGregor, Hayley; Bloom, Gerald

    2016-12-01

    This paper discusses health policy and systems research in complex and rapidly changing contexts. It focuses on ethical issues at stake for researchers working with government policy makers to provide evidence to inform major health systems change at scale, particularly when the dynamic nature of the context and ongoing challenges to the health system can result in unpredictable outcomes. We focus on situations where 'country ownership' of HSR is relatively well established and where there is significant involvement of local researchers and close ties and relationships with policy makers are often present. We frame our discussion around two country case studies with which we are familiar, namely China and South Africa and discuss the implications for conducting 'embedded' research. We suggest that reflexivity is an important concept for health system researchers who need to think carefully about positionality and their normative stance and to use such reflection to ensure that they can negotiate to retain autonomy, whilst also contributing evidence for health system change. A research process informed by the notion of reflexive practice and iterative learning will require a longitudinal review at key points in the research timeline. Such review should include the convening of a deliberative process and should involve a range of stakeholders, including those most likely to be affected by the intended and unintended consequences of change. © 2016 The Authors Developing World Bioethics Published by John Wiley & Sons Ltd.

  6. Bridging the gap: axonal fusion drives rapid functional recovery of the nervous system

    Directory of Open Access Journals (Sweden)

    Jean-Sébastien Teoh

    2018-01-01

    Full Text Available Injuries to the central or peripheral nervous system frequently cause long-term disabilities because damaged neurons are unable to efficiently self-repair. This inherent deficiency necessitates the need for new treatment options aimed at restoring lost function to patients. Compared to humans, a number of species possess far greater regenerative capabilities, and can therefore provide important insights into how our own nervous systems can be repaired. In particular, several invertebrate species have been shown to rapidly initiate regeneration post-injury, allowing separated axon segments to re-join. This process, known as axonal fusion, represents a highly efficient repair mechanism as a regrowing axon needs to only bridge the site of damage and fuse with its separated counterpart in order to re-establish its original structure. Our recent findings in the nematode Caenorhabditis elegans have expanded the promise of axonal fusion by demonstrating that it can restore complete function to damaged neurons. Moreover, we revealed the importance of injury-induced changes in the composition of the axonal membrane for mediating axonal fusion, and discovered that the level of axonal fusion can be enhanced by promoting a neuron's intrinsic growth potential. A complete understanding of the molecular mechanisms controlling axonal fusion may permit similar approaches to be applied in a clinical setting.

  7. Critical capacity, travel time delays and travel time distribution of rapid mass transit systems

    Science.gov (United States)

    Legara, Erika Fille; Monterola, Christopher; Lee, Kee Khoon; Hung, Gih Guang

    2014-07-01

    We set up a mechanistic agent-based model of a rapid mass transit system. Using empirical data from Singapore's unidentifiable smart fare card, we validate our model by reconstructing actual travel demand and duration of travel statistics. We subsequently use this model to investigate two phenomena that are known to significantly affect the dynamics within the RTS: (1) overloading in trains and (2) overcrowding in the RTS platform. We demonstrate that by varying the loading capacity of trains, a tipping point emerges at which an exponential increase in the duration of travel time delays is observed. We also probe the impact on the rail system dynamics of three types of passenger growth distribution across stations: (i) Dirac delta, (ii) uniform and (iii) geometric, which is reminiscent of the effect of land use on transport. Under the assumption of a fixed loading capacity, we demonstrate the dependence of a given origin-destination (OD) pair on the flow volume of commuters in station platforms.

  8. Environmental science applications with Rapid Integrated Mapping and analysis System (RIMS)

    Science.gov (United States)

    Shiklomanov, A.; Prusevich, A.; Gordov, E.; Okladnikov, I.; Titov, A.

    2016-11-01

    The Rapid Integrated Mapping and analysis System (RIMS) has been developed at the University of New Hampshire as an online instrument for multidisciplinary data visualization, analysis and manipulation with a focus on hydrological applications. Recently it was enriched with data and tools to allow more sophisticated analysis of interdisciplinary data. Three different examples of specific scientific applications with RIMS are demonstrated and discussed. Analysis of historical changes in major components of the Eurasian pan-Arctic water budget is based on historical discharge data, gridded observational meteorological fields, and remote sensing data for sea ice area. Express analysis of the extremely hot and dry summer of 2010 across European Russia is performed using a combination of near-real time and historical data to evaluate the intensity and spatial distribution of this event and its socioeconomic impacts. Integrative analysis of hydrological, water management, and population data for Central Asia over the last 30 years provides an assessment of regional water security due to changes in climate, water use and demography. The presented case studies demonstrate the capabilities of RIMS as a powerful instrument for hydrological and coupled human-natural systems research.

  9. Rapid, computer vision-enabled murine screening system identifies neuropharmacological potential of two new mechanisms

    Directory of Open Access Journals (Sweden)

    Steven L Roberds

    2011-09-01

    Full Text Available The lack of predictive in vitro models for behavioral phenotypes impedes rapid advancement in neuropharmacology and psychopharmacology. In vivo behavioral assays are more predictive of activity in human disorders, but such assays are often highly resource-intensive. Here we describe the successful application of a computer vision-enabled system to identify potential neuropharmacological activity of two new mechanisms. The analytical system was trained using multiple drugs that are used clinically to treat depression, schizophrenia, anxiety, and other psychiatric or behavioral disorders. During blinded testing the PDE10 inhibitor TP-10 produced a signature of activity suggesting potential antipsychotic activity. This finding is consistent with TP-10’s activity in multiple rodent models that is similar to that of clinically used antipsychotic drugs. The CK1ε inhibitor PF-670462 produced a signature consistent with anxiolytic activity and, at the highest dose tested, behavioral effects similar to that of opiate analgesics. Neither TP-10 nor PF-670462 was included in the training set. Thus, computer vision-based behavioral analysis can facilitate drug discovery by identifying neuropharmacological effects of compounds acting through new mechanisms.

  10. The improvement of movement and speech during rapid eye movement sleep behaviour disorder in multiple system atrophy.

    Science.gov (United States)

    De Cock, Valérie Cochen; Debs, Rachel; Oudiette, Delphine; Leu, Smaranda; Radji, Fatai; Tiberge, Michel; Yu, Huan; Bayard, Sophie; Roze, Emmanuel; Vidailhet, Marie; Dauvilliers, Yves; Rascol, Olivier; Arnulf, Isabelle

    2011-03-01

    Multiple system atrophy is an atypical parkinsonism characterized by severe motor disabilities that are poorly levodopa responsive. Most patients develop rapid eye movement sleep behaviour disorder. Because parkinsonism is absent during rapid eye movement sleep behaviour disorder in patients with Parkinson's disease, we studied the movements of patients with multiple system atrophy during rapid eye movement sleep. Forty-nine non-demented patients with multiple system atrophy and 49 patients with idiopathic Parkinson's disease were interviewed along with their 98 bed partners using a structured questionnaire. They rated the quality of movements, vocal and facial expressions during rapid eye movement sleep behaviour disorder as better than, equal to or worse than the same activities in an awake state. Sleep and movements were monitored using video-polysomnography in 22/49 patients with multiple system atrophy and in 19/49 patients with Parkinson's disease. These recordings were analysed for the presence of parkinsonism and cerebellar syndrome during rapid eye movement sleep movements. Clinical rapid eye movement sleep behaviour disorder was observed in 43/49 (88%) patients with multiple system atrophy. Reports from the 31/43 bed partners who were able to evaluate movements during sleep indicate that 81% of the patients showed some form of improvement during rapid eye movement sleep behaviour disorder. These included improved movement (73% of patients: faster, 67%; stronger, 52%; and smoother, 26%), improved speech (59% of patients: louder, 55%; more intelligible, 17%; and better articulated, 36%) and normalized facial expression (50% of patients). The rate of improvement was higher in Parkinson's disease than in multiple system atrophy, but no further difference was observed between the two forms of multiple system atrophy (predominant parkinsonism versus cerebellar syndrome). Video-monitored movements during rapid eye movement sleep in patients with multiple system

  11. CE: Original research: hospital system barriers to rapid response team activation: a cognitive work analysis.

    Science.gov (United States)

    Braaten, Jane Saucedo

    2015-02-01

    The goal of rapid response team (RRT) activation in acute care facilities is to decrease mortality from preventable complications, but such efforts have been only moderately successful. Although recent research has shown decreased mortality when RRTs are activated more often, many hospitals have low activation rates. This has been linked to various hospital, team, and nursing factors. Yet there is a dearth of research examining how hospital systems shape nurses' behavior with regard to RRT activation. Making systemic constraints visible and modifying them may be the key to improving RRT activation rates and saving more lives. The purpose of this study was to use cognitive work analysis to describe factors within the hospital system that shape medical-surgical nurses' RRT activation behavior. Cognitive work analysis offers a framework for the study of complex sociotechnical systems. This framework was used as the organizing element of the study. Qualitative descriptive design was used to obtain data to fill the framework's five domains: resources, tasks, strategies, social systems, and worker competency. Data were obtained from interviews with 12 medical-surgical nurses and document review. Directed content analysis was used to place the obtained data into the framework's predefined domains. Many system factors affected participants' decisions to activate or not activate an RRT. Systemic constraints, especially in cases of subtle or gradual clinical changes, included a lack of adequate information, the availability of multiple strategies, the need to justify RRT activation, a scarcity of human resources, and informal hierarchical norms in the hospital culture. The most profound constraint was the need to justify the call. Justification was based on the objective or subjective nature of clinical changes, whether the nurse expected to be able to "handle" these changes, the presence or absence of a physician, and whether there was an expectation of support from the RRT

  12. Development of a high-speed real-time PCR system for rapid and precise nucleotide recognition

    Science.gov (United States)

    Terazono, Hideyuki; Takei, Hiroyuki; Hattori, Akihiro; Yasuda, Kenji

    2010-04-01

    Polymerase chain reaction (PCR) is a common method used to create copies of a specific target region of a DNA sequence and to produce large quantities of DNA. A few DNA molecules, which act as templates, are rapidly amplified by PCR into many billions of copies. PCR is a key technology in genome-based biological analysis, revolutionizing many life science fields such as medical diagnostics, food safety monitoring, and countermeasures against bioterrorism. Thus, many applications have been developed with the thermal cycling. For these PCR applications, one of the most important key factors is reduction in the data acquisition time. To reduce the acquisition time, it is necessary to decrease the temperature transition time between the high and low ends as much as possible. We have developed a novel rapid real-time PCR system based on rapid exchange of media maintained at different temperatures. This system consists of two thermal reservoirs and a reaction chamber for PCR observation. The temperature transition was achieved within 0.3 sec, and good thermal stability was achieved during thermal cycling with rapid exchange of circulating media. This system allows rigorous optimization of the temperatures required for each stage of the PCR processes. Resulting amplicons were confirmed by electrophoresis. Using the system, rapid DNA amplification was accomplished within 3.5 min, including initial heating and complete 50 PCR cycles. It clearly shows that the device could allow us faster temperature switching than the conventional conduction-based heating systems based on Peltier heating/cooling.

  13. RAAIS: Rapid Appraisal of Agricultural Innovation Systems (Part II). Integrated analysis of parasitic weed problems in rice in Tanzania

    NARCIS (Netherlands)

    Schut, M.; Rodenburg, J.; Klerkx, L.W.A.; Kayeke, J.; Ast, van A.; Bastiaans, L.

    2015-01-01

    Parasitic weeds such as Striga spp and Rhamphicarpa fistulosa in smallholder rice production systems form an increasing problem for food and income security in sub-Saharan Africa. In this paper we implement the Rapid Appraisal of Agricultural Innovation Systems (RAAIS) as a diagnostic tool to

  14. "Identifying the hospitalised patient in crisis"--a consensus conference on the afferent limb of rapid response systems

    DEFF Research Database (Denmark)

    DeVita, Michael A; Smith, Gary B; Adam, Sheila K

    2010-01-01

    Most reports of Rapid Response Systems (RRS) focus on the efferent, response component of the system, although evidence suggests that improved vital sign monitoring and recognition of a clinical crisis may have outcome benefits. There is no consensus regarding how best to detect patient deteriora...

  15. An efficient rapid warning system for earthquakes in the European - Mediterranean region

    International Nuclear Information System (INIS)

    Mazet-Roux, G.; Bossu, R; Tome, M.; Giovambattista, R. Di

    2002-01-01

    Every year a few damaging earthquakes occur in the European-Mediterranean region. It is therefore indispensable to operate a real-time warning system in order to provide rapidly reliable estimates of the location, depth and magnitude of these seismic events. In order to provide this information in a timely manner both to the scientific community and to the European and national authorities dealing with natural hazards and relief organisation, the European-Mediterranean Seismological Centre (EMSC) has federated a network of seismic networks exchanging their data in quasi real-time. Today, thanks to the Internet, the EMSC receives real-time information about earthquakes from about thirty seismological institutes. As soon as data reach the EMSC, they are displayed on the EMSC Web pages (www.emsc-csem.org). A seismic alert is generated for any potentially damaging earthquake in the European-Mediterranean region and disseminated within one hour following its occurrence. Potentially damaging earthquakes are defined as seismic events of magnitude 5 or above in the European-Mediterranean region. The utility of this EMSC service is clearly demonstrated by its following among the public: EMSC e-mail dissemination list has been subscribed by about 300 institutions (ECHO, NGO, civil defence services, seismological institutes) or individuals and the rate of internet connections to EMSC web site dramatically increase following an alert. The aim of this presentation is to give a complete technical description of the EMSC warning system. We will also take this opportunity to thank each of the contributing institutions for their support and efforts to enhance the system performances. (authors)

  16. Perspectives of Patients With Cancer on the Ethics of Rapid-Learning Health Systems.

    Science.gov (United States)

    Jagsi, Reshma; Griffith, Kent A; Sabolch, Aaron; Jones, Rochelle; Spence, Rebecca; De Vries, Raymond; Grande, David; Bradbury, Angela R

    2017-07-10

    Purpose To inform the evolving implementation of CancerLinQ and other rapid-learning systems for oncology care, we sought to evaluate perspectives of patients with cancer regarding ethical issues. Methods Using the GfK Group online research panel, representative of the US population, we surveyed 875 patients with cancer; 621 (71%) responded. We evaluated perceptions of appropriateness (scored from 1 to 10; 10, very appropriate) using scenarios and compared responses by age, race, and education. We constructed a scaled measure of comfort with secondary use of deidentified medical information and evaluated its correlates in a multivariable model. Results Of the sample, 9% were black and 9% Hispanic; 38% had completed high school or less, and 59% were age ≥ 65 years. Perceptions of appropriateness were highest when consent was obtained and university researchers used data to publish a research study (weighted mean appropriateness, 8.47) and lowest when consent was not obtained and a pharmaceutical company used data for marketing (weighted mean appropriateness, 2.7). Most respondents (72%) thought secondary use of data for research was very important, although those with lower education were less likely to endorse this (62% v 78%; P < .001). Overall, 35% believed it was necessary to obtain consent each time such research was to be performed; this proportion was higher among blacks/Hispanics than others (48% v 33%; P = .02). Comfort with the use of deidentified information from medical records varied by scenario and overall was associated with distrust in the health care system. Conclusion Perceptions of patients with cancer regarding secondary data use depend on the user and the specific use of the data, while also frequently differing by patient sociodemographic factors. Such information is critical to inform ongoing efforts to implement oncology learning systems.

  17. Dynamic Performance of Maximum Power Point Trackers in TEG Systems Under Rapidly Changing Temperature Conditions

    Science.gov (United States)

    Man, E. A.; Sera, D.; Mathe, L.; Schaltz, E.; Rosendahl, L.

    2016-03-01

    Characterization of thermoelectric generators (TEG) is widely discussed and equipment has been built that can perform such analysis. One method is often used to perform such characterization: constant temperature with variable thermal power input. Maximum power point tracking (MPPT) methods for TEG systems are mostly tested under steady-state conditions for different constant input temperatures. However, for most TEG applications, the input temperature gradient changes, exposing the MPPT to variable tracking conditions. An example is the exhaust pipe on hybrid vehicles, for which, because of the intermittent operation of the internal combustion engine, the TEG and its MPPT controller are exposed to a cyclic temperature profile. Furthermore, there are no guidelines on how fast the MPPT must be under such dynamic conditions. In the work discussed in this paper, temperature gradients for TEG integrated in several applications were evaluated; the results showed temperature variation up to 5°C/s for TEG systems. Electrical characterization of a calcium-manganese oxide TEG was performed at steady-state for different input temperatures and a maximum temperature of 401°C. By using electrical data from characterization of the oxide module, a solar array simulator was emulated to perform as a TEG. A trapezoidal temperature profile with different gradients was used on the TEG simulator to evaluate the dynamic MPPT efficiency. It is known that the perturb and observe (P&O) algorithm may have difficulty accurately tracking under rapidly changing conditions. To solve this problem, a compromise must be found between the magnitude of the increment and the sampling frequency of the control algorithm. The standard P&O performance was evaluated experimentally by using different temperature gradients for different MPPT sampling frequencies, and efficiency values are provided for all cases. The results showed that a tracking speed of 2.5 Hz can be successfully implemented on a TEG

  18. 'Rapid Learning health care in oncology' - An approach towards decision support systems enabling customised radiotherapy'

    NARCIS (Netherlands)

    Lambin, P.; Roelofs, E.; Reymen, B.; Velazquez, E.R.; Buijsen, J.; Zegers, C.M.; Carvalho, S.; Leijenaar, R.T.; Nalbantov, G.; Oberije, C.; Marshall, M.; Hoebers, F.; Troost, E.G.C.; Stiphout, R.G.; Elmpt, W. van; Weijden, T.T. van der; Boersma, L.; Valentini, V.; Dekker, A.

    2013-01-01

    PURPOSE: An overview of the Rapid Learning methodology, its results, and the potential impact on radiotherapy. MATERIAL AND RESULTS: Rapid Learning methodology is divided into four phases. In the data phase, diverse data are collected about past patients, treatments used, and outcomes. Innovative

  19. Research on the Application of Rapid Surveying and Mapping for Large Scare Topographic Map by Uav Aerial Photography System

    Science.gov (United States)

    Gao, Z.; Song, Y.; Li, C.; Zeng, F.; Wang, F.

    2017-08-01

    Rapid acquisition and processing method of large scale topographic map data, which relies on the Unmanned Aerial Vehicle (UAV) low-altitude aerial photogrammetry system, is studied in this paper, elaborating the main work flow. Key technologies of UAV photograph mapping is also studied, developing a rapid mapping system based on electronic plate mapping system, thus changing the traditional mapping mode and greatly improving the efficiency of the mapping. Production test and achievement precision evaluation of Digital Orth photo Map (DOM), Digital Line Graphic (DLG) and other digital production were carried out combined with the city basic topographic map update project, which provides a new techniques for large scale rapid surveying and has obvious technical advantage and good application prospect.

  20. Rapid Mergers in a Mixed System of Black Holes and Neutron Stars

    Science.gov (United States)

    Tagawa, Hiromichi; Umemura, Masayuki

    Recently, it has been argued that r-process elements in galaxies primarily originate from the mergers of double neutron stars (NSs) and black hole (BH)-NS. However, there is a momentous problem that the merger timescale is estimated to be much longer than the production timescale of r-process elements inferred from metal poor stars in the Galactic halo. To solve this problem, we propose the rapid merger processes in gas-rich first-generation objects in a high redshift epoch. In such an era, it is expected that the dynamical friction by dense gas effectively promotes the merger of compact objects. To explore the possibility of mergers in a system composed of multiple NSs as well as BHs, we perform post Newtonian N-body simulations, incorporating the gas dynamical friction, the gas accretion, and the gravitational wave emission including the recoil kick. As a result, we find that NS-NS or NS-BH can merge within 10 Myr in first-generation objects. Furthermore, to satisfy the condition of the mass ejection of r-process elements, the gas accretion rate need to be lower than 0.1 Hoyle-Lyttleton accretion rate. These results imply that the mergers in early cosmic epochs may reconcile the conflict on the timescale of NS mergers.

  1. Proposed second harmonic acceleration system for the intense pulsed neutron source rapid cycling synchrotron

    International Nuclear Information System (INIS)

    Norem, J.; Brandeberry, F.; Rauchas, A.

    1983-01-01

    The Rapid Cycling Synchrotron (RCS) of the Intense Pulsed Neutron Source (IPNS) operating at Argonne National Laboratory is presently producing intensities of 2 to 2.5 x 10 12 protons per pulse (ppp) with the addition of a new ion source. This intensity is close to the space charge limit of the machine, estimated at approx.3 x 10 12 ppp, depending somewhat on the available aperture. With the present good performance in mind, accelerator improvements are being directed at: (1) increasing beam intensities for neutron science; (2) lowering acceleration losses to minimize activation; and (3) gaining better control of the beam so that losses can be made to occur when and where they can be most easily controlled. On the basis of preliminary measurements, we are now proposing a third cavity for the RF systems which would provide control of the longitudinal bunch shape during the cycle which would permit raising the effective space charge limit of the accelerator and reducing losses

  2. The Rotary Zone Thermal Cycler: A Low-Power System Enabling Automated Rapid PCR

    Science.gov (United States)

    Bartsch, Michael S.; Renzi, Ronald F.; Van de Vreugde, James L.; Kim, Hanyoup; Knight, Daniel L.; Sinha, Anupama; Branda, Steven S.; Patel, Kamlesh D.

    2015-01-01

    Advances in molecular biology, microfluidics, and laboratory automation continue to expand the accessibility and applicability of these methods beyond the confines of conventional, centralized laboratory facilities and into point of use roles in clinical, military, forensic, and field-deployed applications. As a result, there is a growing need to adapt the unit operations of molecular biology (e.g., aliquoting, centrifuging, mixing, and thermal cycling) to compact, portable, low-power, and automation-ready formats. Here we present one such adaptation, the rotary zone thermal cycler (RZTC), a novel wheel-based device capable of cycling up to four different fixed-temperature blocks into contact with a stationary 4-microliter capillary-bound sample to realize 1-3 second transitions with steady state heater power of less than 10 W. We demonstrate the utility of the RZTC for DNA amplification as part of a highly integrated rotary zone PCR (rzPCR) system that uses low-volume valves and syringe-based fluid handling to automate sample loading and unloading, thermal cycling, and between-run cleaning functionalities in a compact, modular form factor. In addition to characterizing the performance of the RZTC and the efficacy of different online cleaning protocols, we present preliminary results for rapid single-plex PCR, multiplex short tandem repeat (STR) amplification, and second strand cDNA synthesis. PMID:25826708

  3. Utility and assessment of non-technical skills for rapid response systems and medical emergency teams.

    Science.gov (United States)

    Chalwin, R P; Flabouris, A

    2013-09-01

    Efforts are ongoing to improve outcomes from cardiac arrest and medical emergencies. A promising quality improvement modality is use of non-technical skills (NTS) that aim to address human factors through improvements in performance of leadership, communication, situational awareness and decision-making. Originating in the airline industry, NTS training has been successfully introduced into anaesthesia, surgery, emergency medicine and other acute medical specialities. Some aspects of NTS have already achieved acceptance for cardiac arrest teams. Leadership skills are emphasised in advanced life support training and have shown favourable results when employed in simulated and clinical resuscitation scenarios. The application of NTS in medical emergency teams as part of a rapid response system attending medical emergencies is less certain; however, observations of simulations have also shown promise. This review highlights the potential benefits of NTS competency for cardiac arrest teams and, more importantly, medical emergency teams because of the diversity of clinical scenarios encountered. Discussion covers methods to assess and refine NTS and NTS training to optimise performance in the clinical environment. Increasing attention should be applied to yielding meaningful patient and organisational outcomes from use of NTS. Similarly, implementation of any training course should receive appropriate scrutiny to refine team and institutional performance. © 2013 The Authors; Internal Medicine Journal © 2013 Royal Australasian College of Physicians.

  4. Rapid Surface Sampling and Archival Record (RSSAR) system. Final report, October 1995--May 1997

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-12-31

    This report describes the results of Phase 2 efforts to develop a Rapid Surface Sampling and Archival Record (RSSAR) System for the detection of semivolatile organic contaminants on concrete, transite, and metal surfaces. The characterization of equipment and building surfaces for the presence of contaminants as part of building decontamination and decommissioning activities is an immensely large task of concern to both government and industry. Because of the high cost of hazardous waste disposal, old, contaminated buildings cannot simply be demolished and scrapped. Contaminated and clean materials must be clearly identified and segregated so that the clean material can be recycled or reused, if possible, or disposed of more cheaply as nonhazardous waste. DOE has a number of sites requiring surface characterization. These sites are large, contain very heterogeneous patterns of contamination (requiring high sampling density), and will thus necessitate an enormous number of samples to be taken and analyzed. Characterization of building and equipment surfaces will be needed during initial investigations, during cleanup operations, and during the final confirmation process, increasing the total number of samples well beyond that needed for initial characterization. This multiplicity of information places a premium on the ability to handle and track data as efficiently as possible.

  5. The rotary zone thermal cycler: a low-power system enabling automated rapid PCR.

    Directory of Open Access Journals (Sweden)

    Michael S Bartsch

    Full Text Available Advances in molecular biology, microfluidics, and laboratory automation continue to expand the accessibility and applicability of these methods beyond the confines of conventional, centralized laboratory facilities and into point of use roles in clinical, military, forensic, and field-deployed applications. As a result, there is a growing need to adapt the unit operations of molecular biology (e.g., aliquoting, centrifuging, mixing, and thermal cycling to compact, portable, low-power, and automation-ready formats. Here we present one such adaptation, the rotary zone thermal cycler (RZTC, a novel wheel-based device capable of cycling up to four different fixed-temperature blocks into contact with a stationary 4-microliter capillary-bound sample to realize 1-3 second transitions with steady state heater power of less than 10 W. We demonstrate the utility of the RZTC for DNA amplification as part of a highly integrated rotary zone PCR (rzPCR system that uses low-volume valves and syringe-based fluid handling to automate sample loading and unloading, thermal cycling, and between-run cleaning functionalities in a compact, modular form factor. In addition to characterizing the performance of the RZTC and the efficacy of different online cleaning protocols, we present preliminary results for rapid single-plex PCR, multiplex short tandem repeat (STR amplification, and second strand cDNA synthesis.

  6. Diffuse-interface model for rapid phase transformations in nonequilibrium systems.

    Science.gov (United States)

    Galenko, Peter; Jou, David

    2005-04-01

    A thermodynamic approach to rapid phase transformations within a diffuse interface in a binary system is developed. Assuming an extended set of independent thermodynamic variables formed by the union of the classic set of slow variables and the space of fast variables, we introduce finiteness of the heat and solute diffusive propagation at the finite speed of the interface advancing. To describe transformations within the diffuse interface, we use the phase-field model which allows us to follow steep but smooth changes of phase within the width of the diffuse interface. Governing equations of the phase-field model are derived for the hyperbolic model, a model with memory, and a model of nonlinear evolution of transformation within the diffuse interface. The consistency of the model is proved by the verification of the validity of the condition of positive entropy production and by outcomes of the fluctuation-dissipation theorem. A comparison with existing sharp-interface and diffuse-interface versions of the model is given.

  7. The rapid secondary electron imaging system of the proton beam writer at CIBA

    International Nuclear Information System (INIS)

    Udalagama, C.N.B.; Bettiol, A.A.; Kan, J.A. van; Teo, E.J.; Watt, F.

    2007-01-01

    The recent years have witnessed a proliferation of research involving proton beam (p-beam) writing. This has prompted investigations into means of optimizing the process of p-beam writing so as to make it less time consuming and more efficient. One such avenue is the improvement of the pre-writing preparatory procedures that involves beam focusing and sample alignment which is centred on acquiring images of a resolution standard or sample. The conventional mode of imaging used up to now has utilized conventional nuclear microprobe signals that are of a pulsed nature and are inherently slow. In this work, we report the new imaging system that has been introduced, which uses proton induced secondary electrons. This in conjunction with software developed in-house that uses a National Instruments DAQ card with hardware triggering, facilitates large data transfer rates enabling rapid imaging. Frame rates as much as 10 frames/s have been achieved at an imaging resolution of 512 x 512 pixels

  8. Cryogenic optical systems for the rapid infrared imager/spectrometer (RIMAS)

    Science.gov (United States)

    Capone, John I.; Content, David A.; Kutyrev, Alexander S.; Robinson, Frederick D.; Lotkin, Gennadiy N.; Toy, Vicki L.; Veilleux, Sylvain; Moseley, Samuel H.; Gehrels, Neil A.; Vogel, Stuart N.

    2014-07-01

    The Rapid Infrared Imager/Spectrometer (RIMAS) is designed to perform follow-up observations of transient astronomical sources at near infrared (NIR) wavelengths (0.9 - 2.4 microns). In particular, RIMAS will be used to perform photometric and spectroscopic observations of gamma-ray burst (GRB) afterglows to compliment the Swift satellite's science goals. Upon completion, RIMAS will be installed on Lowell Observatory's 4.3 meter Discovery Channel Telescope (DCT) located in Happy Jack, Arizona. The instrument's optical design includes a collimator lens assembly, a dichroic to divide the wavelength coverage into two optical arms (0.9 - 1.4 microns and 1.4 - 2.4 microns respectively), and a camera lens assembly for each optical arm. Because the wavelength coverage extends out to 2.4 microns, all optical elements are cooled to ~70 K. Filters and transmission gratings are located on wheels prior to each camera allowing the instrument to be quickly configured for photometry or spectroscopy. An athermal optomechanical design is being implemented to prevent lenses from loosing their room temperature alignment as the system is cooled. The thermal expansion of materials used in this design have been measured in the lab. Additionally, RIMAS has a guide camera consisting of four lenses to aid observers in passing light from target sources through spectroscopic slits. Efforts to align these optics are ongoing.

  9. Rapid Surface Sampling and Archival Record (RSSAR) system. Final report, October 1995 - May 1997

    International Nuclear Information System (INIS)

    1998-01-01

    This report describes the results of Phase 2 efforts to develop a Rapid Surface Sampling and Archival Record (RSSAR) System for the detection of semivolatile organic contaminants on concrete, transite, and metal surfaces. The characterization of equipment and building surfaces for the presence of contaminants as part of building decontamination and decommissioning activities is an immensely large task of concern to both government and industry. Because of the high cost of hazardous waste disposal, old, contaminated buildings cannot simply be demolished and scrapped. Contaminated and clean materials must be clearly identified and segregated so that the clean material can be recycled or reused, if possible, or disposed of more cheaply as nonhazardous waste. DOE has a number of sites requiring surface characterization. These sites are large, contain very heterogeneous patterns of contamination (requiring high sampling density), and will thus necessitate an enormous number of samples to be taken and analyzed. Characterization of building and equipment surfaces will be needed during initial investigations, during cleanup operations, and during the final confirmation process, increasing the total number of samples well beyond that needed for initial characterization. This multiplicity of information places a premium on the ability to handle and track data as efficiently as possible

  10. A rapid and efficient in vitro regeneration system for lettuce (Lactuca sativa L.).

    Science.gov (United States)

    Armas, Isabel; Pogrebnyak, Natalia; Raskin, Ilya

    2017-01-01

    Successful biotechnological improvement of crop plants requires a reliable and efficient in vitro regeneration system. Lettuce ( Lactuca sativa L.), one the most important vegetable crops worldwide, is strongly genotype-dependent in terms of regeneration capacity, limiting the potential for biotechnological improvement of cultivars which show recalcitrance under currently available protocols. The effect of different nutrient sources, plant hormone combinations and activated charcoal supplementation on shoot induction efficiency was evaluated on the cultivar 'RSL NFR', which had previously shown poor regeneration efficiency. Multiple shoot organogenesis from cotyledon explants was recorded at the highest frequency and speed on Murashige and Skoog regeneration medium supplemented with 200 mg/l of activated charcoal, 3% sucrose, 10 mg/l benzylaminopurine and 0.5 mg/l naphthaleneacetic acid, which induced shoots through direct regeneration in 90.8 ± 7.9% of explants. High shoot induction efficiency was also observed, albeit not quantified, when using this medium on some other cultivars. This activated charcoal-containing regeneration medium might offer a rapid and efficient option for direct shoot induction in some lettuce genotypes that do not respond well to common lettuce regeneration protocols. This is also the first report of the effect of activated charcoal in lettuce tissue culture.

  11. Twelve-month results of the rapid renal sympathetic denervation for resistant hypertension using the OneShotTM ablation system (RAPID) study.

    Science.gov (United States)

    Verheye, Stefan; Ormiston, John; Bergmann, Martin W; Sievert, Horst; Schwindt, Arne; Werner, Nikos; Vogel, Britta; Colombo, Antonio

    2015-02-01

    Renal denervation has emerged as a treatment option for patients with drug-resistant hypertension. This study was designed to assess the safety and effectiveness of the OneShotª Renal Denervation System. RAPID is a prospective, multicentre, single-arm study which enrolled 50 patients at 11 clinical sites in Europe and New Zealand. Eligible patients had an office systolic blood pressure (SBP) ≥160 mmHg and were on a stable regimen of ≥3 antihypertensive medications including a diuretic. The primary safety endpoints were acute procedural safety at discharge and chronic procedural safety at six months. The primary effectiveness endpoint was the rate of office SBP reduction ≥10 mmHg at six months compared to baseline. While not a predefined endpoint, change in 24-hour ambulatory BP was evaluated. The mean baseline office SBP and diastolic BP measurements were 181.6±20.8 and 95.5±15.5 mmHg, respectively. Patients were on a mean of 5.1 antihypertensive medications at baseline. The mean office BP decreased by -20/-8 mmHg (prenal artery injury or SAE/adverse device effects at six months. The results of the RAPID study demonstrate safe delivery of RF energy by the OneShot Renal Denervation System for renal sympathetic denervation and sustained efficacy, as evidenced by a significant reduction in office and 24-hour ABPM for six months, which was sustained up to 12 months. ClinicalTrials.gov Identifier: NCT01520506.

  12. Consumer participation in early detection of the deteriorating patient and call activation to rapid response systems: a literature review.

    Science.gov (United States)

    Vorwerk, Jane; King, Lindy

    2016-01-01

    This review investigated the impact of consumer participation in recognition of patient deterioration and response through call activation in rapid response systems. Nurses and doctors have taken the main role in recognition and response to patient deterioration through hospital rapid response systems. Yet patients and visitors (consumers) have appeared well placed to notice early signs of deterioration. In response, many hospitals have sought to partner health professionals with consumers in detection and response to early deterioration. However, to date, there have been no published research-based reviews to establish the impact of introducing consumer involvement into rapid response systems. A critical research-based review was undertaken. A comprehensive search of databases from 2006-2014 identified 11 studies. Critical appraisal of these studies was undertaken and thematic analysis of the findings revealed four major themes. Following implementation of the consumer activation programmes, the number of calls made by the consumers following detection of deterioration increased. Interestingly, the number of staff calls also increased. Importantly, mortality numbers were found to decrease in one major study following the introduction of consumer call activation. Consumer and staff knowledge and satisfaction with the new programmes indicated mixed results. Initial concerns of the staff over consumer involvement overwhelming the rapid response systems did not eventuate. Evaluation of successful consumer-activated programmes indicated the importance of: effective staff education and training; ongoing consumer education by nurses and clear educational materials. Findings indicated positive patient outcomes following introduction of consumer call activation programmes within rapid response systems. Effective consumer programmes included information that was readily accessible, easy-to-understand and available in a range of multimedia materials accompanied by the

  13. Effects of elevated atmospheric carbon dioxide concentrations on water and acid requirements of soybeans grown in a recirculating hydroponic system

    Science.gov (United States)

    Mackowiak, C. L.; Wheeler, R. M.; Lowery, W.; Sager, J. C.

    1990-01-01

    Establishing mass budgets of various crop needs, i.e. water and nutrients, in different environments is essential for the Controlled Ecological Life Support System (CELSS). The effects of CO2 (500 and 1000 umol mol (exp -1)) on water and acid use (for pH control) by soybeans in a recirculating hydroponic system were examined. Plants of cvs. McCall and Pixie were grown for 90 days using the nutrient film technique (NFT) and a nitrate based nutrient solution. System acid use for both CO2 levels peaked near 4 weeks during a phase of rapid vegetative growth, but acid use decreased more rapidly under 500 compared to 1000 umol mol (exp GR) CO2. Total system water use by 500 and 1000 umol mol (exp -1) plants was similar, leaving off at 5 weeks and declining as plants senesced (ca. 9 weeks). However, single leaf transpiration rates were consistently lower at 1000 umol mol (exp -1). The data suggest that high CO2 concentrations increase system acid (and nutrient) use because of increased vegetative growth, which in turn negates the benefit of reduced water use (lower transpiration rates) per unit leaf area.

  14. Toward tsunami early warning system in Indonesia by using rapid rupture durations estimation

    International Nuclear Information System (INIS)

    Madlazim

    2012-01-01

    Indonesia has Indonesian Tsunami Early Warning System (Ina-TEWS) since 2008. The Ina-TEWS has used automatic processing on hypocenter; Mwp, Mw (mB) and Mj. If earthquake occurred in Ocean, depth 7, then Ina-TEWS announce early warning that the earthquake can generate tsunami. However, the announcement of the Ina-TEWS is still not accuracy. Purposes of this research are to estimate earthquake rupture duration of large Indonesia earthquakes that occurred in Indian Ocean, Java, Timor sea, Banda sea, Arafura sea and Pasific ocean. We analyzed at least 330 vertical seismogram recorded by IRIS-DMC network using a direct procedure for rapid assessment of earthquake tsunami potential using simple measures on P-wave vertical seismograms on the velocity records, and the likelihood that the high-frequency, apparent rupture duration, T dur . T dur can be related to the critical parameters rupture length (L), depth (z), and shear modulus (μ) while T dur may be related to wide (W), slip (D), z or μ. Our analysis shows that the rupture duration has a stronger influence to generate tsunami than Mw and depth. The rupture duration gives more information on tsunami impact, Mo/μ, depth and size than Mw and other currently used discriminants. We show more information which known from the rupture durations. The longer rupture duration, the shallower source of the earthquake. For rupture duration greater than 50 s, the depth less than 50 km, Mw greater than 7, the longer rupture length, because T dur is proportional L and greater Mo/μ. Because Mo/μ is proportional L. So, with rupture duration information can be known information of the four parameters. We also suggest that tsunami potential is not directly related to the faulting type of source and for events that have rupture duration greater than 50 s, the earthquakes generated tsunami. With available real-time seismogram data, rapid calculation, rupture duration discriminant can be completed within 4–5 min after an earthquake

  15. Ranking of small scale proposals for water system repair using the Rapid Impact Assessment Matrix (RIAM)

    Energy Technology Data Exchange (ETDEWEB)

    Shakib-Manesh, T.E.; Hirvonen, K.O.; Jalava, K.J.; Ålander, T.; Kuitunen, M.T., E-mail: markku.kuitunen@jyu.fi

    2014-11-15

    Environmental impacts of small scale projects are often assessed poorly, or not assessed at all. This paper examines the usability of the Rapid Impact Assessment Matrix (RIAM) as a tool to prioritize project proposals for small scale water restoration projects in relation to proposals' potential to improve the environment. The RIAM scoring system was used to assess and rank the proposals based on their environmental impacts, the costs of the projects to repair the harmful impacts, and the size of human population living around the sites. A four-member assessment group (The expert panel) gave the RIAM-scores to the proposals. The assumed impacts of the studied projects at the Eastern Finland water systems were divided into the ecological and social impacts. The more detailed assessment categories of the ecological impacts in this study were impacts on landscape, natural state, and limnology. The social impact categories were impacts to recreational use of the area, fishing, industry, population, and economy. These impacts were scored according to their geographical and social significance, their magnitude of change, their character, permanence, reversibility, and cumulativeness. The RIAM method proved to be an appropriate and recommendable method for the small-scale assessment and prioritizing of project proposals. If the assessments are well documented, the RIAM can be a method for easy assessing and comparison of the various kinds of projects. In the studied project proposals there were no big surprises in the results: the best ranks were received by the projects, which were assumed to return watersheds toward their original state.

  16. Fast Moment Magnitude Determination from P-wave Trains for Bucharest Rapid Early Warning System (BREWS)

    Science.gov (United States)

    Lizurek, Grzegorz; Marmureanu, Alexandru; Wiszniowski, Jan

    2017-03-01

    Bucharest, with a population of approximately 2 million people, has suffered damage from earthquakes in the Vrancea seismic zone, which is located about 170 km from Bucharest, at a depth of 80-200 km. Consequently, an earthquake early warning system (Bucharest Rapid earthquake Early Warning System or BREWS) was constructed to provide some warning about impending shaking from large earthquakes in the Vrancea zone. In order to provide quick estimates of magnitude, seismic moment was first determined from P-waves and then a moment magnitude was determined from the moment. However, this magnitude may not be consistent with previous estimates of magnitude from the Romanian Seismic Network. This paper introduces the algorithm using P-wave spectral levels and compares them with catalog estimates. The testing procedure used waveforms from about 90 events with catalog magnitudes from 3.5 to 5.4. Corrections to the P-wave determined magnitudes according to dominant intermediate depth events mechanism were tested for November 22, 2014, M5.6 and October 17, M6 events. The corrections worked well, but unveiled overestimation of the average magnitude result of about 0.2 magnitude unit in the case of shallow depth event ( H < 60 km). The P-wave spectral approach allows for the relatively fast estimates of magnitude for use in BREWS. The average correction taking into account the most common focal mechanism for radiation pattern coefficient may lead to overestimation of the magnitude for shallow events of about 0.2 magnitude unit. However, in case of events of intermediate depth of M6 the resulting M w is underestimated at about 0.1-0.2. We conclude that our P-wave spectral approach is sufficiently robust for the needs of BREWS for both shallow and intermediate depth events.

  17. Urban Air Pollution in Taiwan before and after the Installation of a Mass Rapid Transit System.

    Science.gov (United States)

    Ding, Pei-Hsiou; Wang, Gen-Shuh; Chen, Bing-Yu; Wan, Gwo-Hwa

    2016-09-01

    Urbanization causes air pollution in metropolitan areas, coupled with meteorological factors that affect air quality. Although previous studies focused on the relationships of urbanization, air pollution, and climate change in Western countries, this study evaluated long-term variations of air quality and meteorological factors in Taiwanese metropolitan areas (Taipei area, Taichung City, and Kaohsiung City) and a rural area (Hualien County) between 1993 and 2012. The influence of a mass rapid transit (MRT) system on air quality was also evaluated. Air pollutant concentrations and meteorology data were collected from Taiwan Environmental Protection Administration (TEPA) air monitoring stations and Central Weather Bureau stations in the surveyed areas, respectively. Analyses indicate that levels of air pollution in metropolitan areas were greater than in the rural area. Kaohsiung City had the highest levels of O, SO, and particulate matter 2.5 or 10 µm in diameter (PM and PM). Clear downward trends for CO, NO, PM, PM, and especially SO concentrations were found in the surveyed areas, whereas O showed no decrease. Both O and PM concentrations showed similar bimodal seasonal distributions. Taiwan's air quality has improved significantly since 1993, indicating the effectiveness of promoting air pollution strategies and policies by the TEPA. Air pollution had an obvious improvement in Taipei area after the MRT system began operations in 1996. Because global climate may potentially affect urban air pollution in Taiwan, further study to clarify the mechanisms by which air pollution may affect human health and other biological effects is warranted. Copyright © by the American Society of Agronomy, Crop Science Society of America, and Soil Science Society of America, Inc.

  18. Rapid Syphilis Tests as Catalysts for Health Systems Strengthening: A Case Study from Peru

    Science.gov (United States)

    García, Patricia J.; Cárcamo, César P.; Chiappe, Marina; Valderrama, Maria; La Rosa, Sayda; Holmes, King K.; Mabey, David C. W.; Peeling, Rosanna W.

    2013-01-01

    Objectives Untreated maternal syphilis leads to adverse pregnancy outcomes. The use of point of care tests (POCT) offers an opportunity to improve screening coverage for syphilis and other aspects of health systems. Our objective is to present the experience of the introduction of POCT for syphilis in Peru and describe how new technology can catalyze health system strengthening. Methods The study was implemented from September 2009–November 2010 to assess the feasibility of the use of a POCT for syphilis for screening pregnant women in Lima, Peru. Outcomes measured included access to syphilis screening, treatment coverage, partner treatment, effect on patient flow and service efficiency, acceptability among providers and patients, and sustainability. Results Before the introduction of POCT, a pregnant woman needed 6 visits to the health center in 27 days before she received her syphilis result. We trained 604 health providers and implemented the POCT for syphilis as the “two for one strategy”, offering with one finger stick both syphilis and HIV testing. Implementation of the POCT resulted in testing and treatment on the first visit. Screening and treatment coverages for syphilis improved significantly compared with the previous year. Implementation of POCT has been scaled up nationally since the study ended, and coverages for screening, treatment and partner treatment have remained over 92%. Conclusions Implementation of POCT for syphilis proved feasible and acceptable, and led to improvement in several aspects of health services. For the process to be effective we highlight the importance of: (1) engaging the authorities; (2) dissipating tensions between providers and identifying champions; (3) training according to the needs; (4) providing monitoring, supervision, support and recognition; (5) sharing results and discussing actions together; (6) consulting and obtaining feedback from users; and (7) integrating with other services such as with rapid HIV

  19. Rapid Syphilis Tests as Catalysts for Health Systems Strengthening: A Case Study from Peru.

    Directory of Open Access Journals (Sweden)

    Patricia J García

    Full Text Available Untreated maternal syphilis leads to adverse pregnancy outcomes. The use of point of care tests (POCT offers an opportunity to improve screening coverage for syphilis and other aspects of health systems. Our objective is to present the experience of the introduction of POCT for syphilis in Peru and describe how new technology can catalyze health system strengthening.The study was implemented from September 2009-November 2010 to assess the feasibility of the use of a POCT for syphilis for screening pregnant women in Lima, Peru. Outcomes measured included access to syphilis screening, treatment coverage, partner treatment, effect on patient flow and service efficiency, acceptability among providers and patients, and sustainability.Before the introduction of POCT, a pregnant woman needed 6 visits to the health center in 27 days before she received her syphilis result. We trained 604 health providers and implemented the POCT for syphilis as the "two for one strategy", offering with one finger stick both syphilis and HIV testing. Implementation of the POCT resulted in testing and treatment on the first visit. Screening and treatment coverages for syphilis improved significantly compared with the previous year. Implementation of POCT has been scaled up nationally since the study ended, and coverages for screening, treatment and partner treatment have remained over 92%.Implementation of POCT for syphilis proved feasible and acceptable, and led to improvement in several aspects of health services. For the process to be effective we highlight the importance of: (1 engaging the authorities; (2 dissipating tensions between providers and identifying champions; (3 training according to the needs; (4 providing monitoring, supervision, support and recognition; (5 sharing results and discussing actions together; (6 consulting and obtaining feedback from users; and (7 integrating with other services such as with rapid HIV testing.

  20. Ranking of small scale proposals for water system repair using the Rapid Impact Assessment Matrix (RIAM)

    International Nuclear Information System (INIS)

    Shakib-Manesh, T.E.; Hirvonen, K.O.; Jalava, K.J.; Ålander, T.; Kuitunen, M.T.

    2014-01-01

    Environmental impacts of small scale projects are often assessed poorly, or not assessed at all. This paper examines the usability of the Rapid Impact Assessment Matrix (RIAM) as a tool to prioritize project proposals for small scale water restoration projects in relation to proposals' potential to improve the environment. The RIAM scoring system was used to assess and rank the proposals based on their environmental impacts, the costs of the projects to repair the harmful impacts, and the size of human population living around the sites. A four-member assessment group (The expert panel) gave the RIAM-scores to the proposals. The assumed impacts of the studied projects at the Eastern Finland water systems were divided into the ecological and social impacts. The more detailed assessment categories of the ecological impacts in this study were impacts on landscape, natural state, and limnology. The social impact categories were impacts to recreational use of the area, fishing, industry, population, and economy. These impacts were scored according to their geographical and social significance, their magnitude of change, their character, permanence, reversibility, and cumulativeness. The RIAM method proved to be an appropriate and recommendable method for the small-scale assessment and prioritizing of project proposals. If the assessments are well documented, the RIAM can be a method for easy assessing and comparison of the various kinds of projects. In the studied project proposals there were no big surprises in the results: the best ranks were received by the projects, which were assumed to return watersheds toward their original state

  1. A predictive model for the chemical vapor deposition of polysilicon in a cold wall, rapid thermal system

    Energy Technology Data Exchange (ETDEWEB)

    Toprac, A.J.; Trachtenberg, I.; Edgar, T.F. (Univ. of Texas, Austin, TX (United States). Dept. of Chemical Engineering)

    1994-06-01

    The chemical vapor deposition of polysilicon from thermally activated silane in a cold wall, single-wafer rapid thermal system was studied by experimentation at a variety of low pressure conditions, including very high temperatures. The effect of diluent gas on polysilicon deposition rates was examined using hydrogen, helium, and krypton. A mass-transfer model for the chemical vapor deposition of polysilicon in a cold wall, rapid thermal system was developed. This model was used to produce an empirical rate expression for silicon deposition from silane by regressing kinetic parameters to fit experimental data. The resulting model provided accurate predictions over widely varying conditions in the experimental data.

  2. Optical satellite data volcano monitoring: a multi-sensor rapid response system

    Science.gov (United States)

    Duda, Kenneth A.; Ramsey, Michael; Wessels, Rick L.; Dehn, Jonathan

    2009-01-01

    response program described in this chapter also improves the temporal resolution of the ASTER instrument. ASTER has been acquiring images of volcanic eruptions since soon after its launch in December 1999. An early example included the observations of the large pyroclastic flow deposit emplaced at Bezymianny volcano in Kamchatka, Russia. The first images in March 2000, just weeks after the eruption, revealed the extent, composition, and cooling history of this large deposit and of the active lava dome (Ramsey and Dehn, 2004). The initial results from these early datasets spurred interest in using ASTER data for expanded volcano monitoring in the north Pacific. It also gave rise to the multi-year NASA-funded programs of rapid response scheduling and imaging throughout the Aleutian, Kamchatka and Kurile arcs. Since the formal establishment of the programs, the data have provided detailed descriptions of the eruptions of Augustine, Bezymianny, Kliuchevskoi and Sheveluch volcanoes over the past nine years (Wessels et al., in press; Carter et al., 2007, 2008; Ramsey et al., 2008; Rose and Ramsey, 2009). The initial research focus of this rapid response program was specifically on automating the ASTER sensor’s ability for targeted observational scheduling using the expedited data system. This urgent request protocol is one of the unique characteristics of ASTER. It provides a limited number of emergency observations, typically at a much-improved temporal resolution and quicker turnaround with data processing in the United States rather than in Japan. This can speed the reception of the processed data by several days to a week. The ongoing multi-agency research and operational collaboration has been highly successful. AVO serves as the primary source for status information on volcanic activity, working closely with the National Weather Service (NWS), Federal Aviation Administration (FAA), military and other state and federal emergency services. Collaboration with the Russian

  3. Rapid Response Command and Control (R2C2): a systems engineering analysis of scaleable communications for Regional Combatant Commanders

    OpenAIRE

    Sullivan, Lisa; Cannon, Lennard; Reyes, Ronel; Bae, Kitan; Colgary, James; Minerowicz, Nick; Leong, Chris; Lim, Harry; Lim, Hang Sheng; Ng, Chin Chin; Neo, Tiong Tien; Tan, Guan Chye; Ng, Yu Loon; Wong, Eric; Wong, Heng Yue

    2006-01-01

    Includes supplementary material. Disaster relief operations, such as the 2005 Tsunami and Hurricane Katrina, and wartime operations, such as Operation Enduring Freedom and Operation Iraqi Freedom, have identified the need for a standardized command and control system interoperable among Joint, Coalition, and Interagency entities. The Systems Engineering Analysis Cohort 9 (SEA-9) Rapid Response Command and Control (R2C2) integrated project team completed a systems engineering (SE) ...

  4. Rapid architecture alternative modeling (RAAM): A framework for capability-based analysis of system of systems architectures

    Science.gov (United States)

    Iacobucci, Joseph V.

    The research objective for this manuscript is to develop a Rapid Architecture Alternative Modeling (RAAM) methodology to enable traceable Pre-Milestone A decision making during the conceptual phase of design of a system of systems. Rather than following current trends that place an emphasis on adding more analysis which tends to increase the complexity of the decision making problem, RAAM improves on current methods by reducing both runtime and model creation complexity. RAAM draws upon principles from computer science, system architecting, and domain specific languages to enable the automatic generation and evaluation of architecture alternatives. For example, both mission dependent and mission independent metrics are considered. Mission dependent metrics are determined by the performance of systems accomplishing a task, such as Probability of Success. In contrast, mission independent metrics, such as acquisition cost, are solely determined and influenced by the other systems in the portfolio. RAAM also leverages advances in parallel computing to significantly reduce runtime by defining executable models that are readily amendable to parallelization. This allows the use of cloud computing infrastructures such as Amazon's Elastic Compute Cloud and the PASTEC cluster operated by the Georgia Institute of Technology Research Institute (GTRI). Also, the amount of data that can be generated when fully exploring the design space can quickly exceed the typical capacity of computational resources at the analyst's disposal. To counter this, specific algorithms and techniques are employed. Streaming algorithms and recursive architecture alternative evaluation algorithms are used that reduce computer memory requirements. Lastly, a domain specific language is created to provide a reduction in the computational time of executing the system of systems models. A domain specific language is a small, usually declarative language that offers expressive power focused on a particular

  5. Coordinated Control of Multi-Agent Systems in Rapidly Varying Environments, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — The main objective of this Phase II STTR project is to develop advanced control algorithms that enable multiple autonomous agents to perform complex tasks in rapidly...

  6. Rapid phenotyping of crop root systems in undisturbed field soils using X-ray computed tomography.

    Science.gov (United States)

    Pfeifer, Johannes; Kirchgessner, Norbert; Colombi, Tino; Walter, Achim

    2015-01-01

    X-ray computed tomography (CT) has become a powerful tool for root phenotyping. Compared to rather classical, destructive methods, CT encompasses various advantages. In pot experiments the growth and development of the same individual root can be followed over time and in addition the unaltered configuration of the 3D root system architecture (RSA) interacting with a real field soil matrix can be studied. Yet, the throughput, which is essential for a more widespread application of CT for basic research or breeding programs, suffers from the bottleneck of rapid and standardized segmentation methods to extract root structures. Using available methods, root segmentation is done to a large extent manually, as it requires a lot of interactive parameter optimization and interpretation and therefore needs a lot of time. Based on commercially available software, this paper presents a protocol that is faster, more standardized and more versatile compared to existing segmentation methods, particularly if used to analyse field samples collected in situ. To the knowledge of the authors this is the first study approaching to develop a comprehensive segmentation method suitable for comparatively large columns sampled in situ which contain complex, not necessarily connected root systems from multiple plants grown in undisturbed field soil. Root systems from several crops were sampled in situ and CT-volumes determined with the presented method were compared to root dry matter of washed root samples. A highly significant (P < 0.01) and strong correlation (R(2) = 0.84) was found, demonstrating the value of the presented method in the context of field research. Subsequent to segmentation, a method for the measurement of root thickness distribution has been used. Root thickness is a central RSA trait for various physiological research questions such as root growth in compacted soil or under oxygen deficient soil conditions, but hardly assessable in high throughput until today, due

  7. Rapid measurement of 131I in the thyroid gland using a portable Ge system

    International Nuclear Information System (INIS)

    Kawamura, H.; Kimura, S.

    2000-01-01

    Rapid yet accurate measurement of the 131 I activity in the thyroid gland as well as in the air, water and vegetation may have an important role in obtaining quantitative information on internal doses for the people living in the vicinity of nuclear facilities shortly after an accidental release of radionuclides. Whole body counting technique is still the standard method for measuring radionuclides in the body while necessity for in situ measurement techniques has considerably increased especially after the Three Mile Island and Chernobyl accidents. For measurement of 131 I in the thyroid gland in emergency situations, NaI (Tl) detectors, as in a scintillation survey meter as in the simplest case, are most often used while measurement of urinary excretions for members of the public may also effective. The scintillation survey meter method, being easily implemented, may not have enough selectivity for radioiodine and even be liable to an elevated background radiation spectrum. This would possibly lead to higher detection limits and lower accuracy. A use of a laboratory Ge (Li) detector system in the thyroidal radioiodine measurement was suggested to overcome the problem. A real measurement with a similar instrument was reported for the residents in U.K. after the Chernobyl accident. A use of a scintillation spectro-survey meter with a NaI (Tl) probe with lead collimation to thyroidal radioiodine measurement was also reported to give satisfactorily accurate evaluation of the thyroidal 131 I burden. In this paper, a movable Ge system was developed for the above purpose and preliminarily evaluated particularly for counting efficiency. It is consisted of a portable high-purity Ge detector and a battery-operated MCA. It employs a laboratory made thin Pb shield with a collimation window and an elevator for the detector platform. The elevator was designed to adjust the height of the thyroid radioiodine probe in relation to the height and position of the neck of a subject

  8. Evaluation of the Specificity and Sensitivity of a Potential Rapid Influenza Screening System

    Science.gov (United States)

    2013-01-01

    misuse of antibiotic therapy for treatment of influenza infections. Rapid identification of influenza infections would further reduce transmission of...amplification tests in combination with Type I BESt™ Cassette have been developed and used to rapidly detect other pathogenic microorgan- isms including herpes ... simplex virus types 1 and 2 (Kim et al., 2011), Mycobacterium tuberculosis (Motre et al., 2011), human immunode- ficiency virus (Tang et al., 2010), and

  9. Integrating unmanned aerial systems and LSPIV for rapid, cost-effective stream gauging

    Science.gov (United States)

    Lewis, Quinn W.; Lindroth, Evan M.; Rhoads, Bruce L.

    2018-05-01

    Quantifying flow in rivers is fundamental to assessments of water supply, water quality, ecological conditions, hydrological responses to storm events, and geomorphological processes. Image-based surface velocity measurements have shown promise in extending the range of discharge conditions that can be measured in the field. The use of Unmanned Aerial Systems (UAS) in image-based measurements of surface velocities has the potential to expand applications of this method. Thus far, few investigations have assessed this potential by evaluating the accuracy and repeatability of discharge measurements using surface velocities obtained from UAS. This study uses large-scale particle image velocimetry (LSPIV) derived from videos captured by cameras on a UAS and a fixed tripod to obtain discharge measurements at ten different stream locations in Illinois, USA. Discharge values are compared to reference values measured by an acoustic Doppler current profiler, a propeller meter, and established stream gauges. The results demonstrate the effects of UAS flight height, camera steadiness and leveling accuracy, video sampling frequency, and LSPIV interrogation area size on surface velocities, and show that the mean difference between fixed and UAS cameras is less than 10%. Differences between LSPIV-derived and reference discharge values are generally less than 20%, not systematically low or high, and not related to site parameters like channel width or depth, indicating that results are relatively insensitive to camera setup and image processing parameters typically required of LSPIV. The results also show that standard velocity indices (between 0.85 and 0.9) recommended for converting surface velocities to depth-averaged velocities yield reasonable discharge estimates, but are best calibrated at specific sites. The study recommends a basic methodology for LSPIV discharge measurements using UAS that is rapid, cost-efficient, and does not require major preparatory work at a

  10. Heavy Metals in Notifications of Rapid Alert System for Food and Feed

    Science.gov (United States)

    Pigłowski, Marcin

    2018-01-01

    Heavy metals represent the fourth most often notified hazard category in the Rapid Alert System for Food and Feed (RASFF) from 1980–2016. The goal of the study was to examine the similarities in notifications of particular heavy metals within the RASFF year, product category, notifying country, country of origin, notification basis, notification type, distribution status, risk decision, and action taken, taking into account the particular product type, such as food, food contact material, and feed. The data originated from the RASFF database. Cluster analysis on pivot tables was applied using joining and two-way joining methods. Most notifications concerned food, in which the highest number were related to mercury, cadmium, chromium, lead, arsenic, and nickel. Notifications were mainly related to fish and food contact materials, in addition to fruits and vegetables, seafood, and dietetic food. The number of notifications decreased in 2015 and 2016. The majority of products were notified by Italy, Spain, Germany, and France. The notified products originated mainly from China and Spain. The notification was usually based on official controls on the market, as well as border controls. The notification types were mainly information, alert, and border rejections. Products were not frequently distributed due to distribution restriction to the notifying country or the possibility of distribution to the market. A risk decision was not usually made. The taken actions included re-dispatch of products, withdrawal from the market, or destruction. The data on heavy metals from the RASFF database can help European and national authorities in shaping public health. PMID:29461471

  11. Heavy Metals in Notifications of Rapid Alert System for Food and Feed

    Directory of Open Access Journals (Sweden)

    Marcin Pigłowski

    2018-02-01

    Full Text Available Heavy metals represent the fourth most often notified hazard category in the Rapid Alert System for Food and Feed (RASFF from 1980–2016. The goal of the study was to examine the similarities in notifications of particular heavy metals within the RASFF year, product category, notifying country, country of origin, notification basis, notification type, distribution status, risk decision, and action taken, taking into account the particular product type, such as food, food contact material, and feed. The data originated from the RASFF database. Cluster analysis on pivot tables was applied using joining and two-way joining methods. Most notifications concerned food, in which the highest number were related to mercury, cadmium, chromium, lead, arsenic, and nickel. Notifications were mainly related to fish and food contact materials, in addition to fruits and vegetables, seafood, and dietetic food. The number of notifications decreased in 2015 and 2016. The majority of products were notified by Italy, Spain, Germany, and France. The notified products originated mainly from China and Spain. The notification was usually based on official controls on the market, as well as border controls. The notification types were mainly information, alert, and border rejections. Products were not frequently distributed due to distribution restriction to the notifying country or the possibility of distribution to the market. A risk decision was not usually made. The taken actions included re-dispatch of products, withdrawal from the market, or destruction. The data on heavy metals from the RASFF database can help European and national authorities in shaping public health.

  12. High-Throughput Lipolysis in 96-Well Plates for Rapid Screening of Lipid-Based Drug Delivery Systems

    DEFF Research Database (Denmark)

    Mosgaard, Mette D; Sassene, Philip J; Mu, Huiling

    2017-01-01

    The high-throughput in vitro intestinal lipolysis model (HTP) applicable for rapid and low-scale screening of lipid-based drug delivery systems (LbDDSs) was optimized and adjusted as to be conducted in 96-well plates (HTP-96). Three different LbDDSs (I-III) loaded with danazol or cinnarizine were...

  13. The role of employee assistance programs in the era of rapid change in the health care delivery system.

    Science.gov (United States)

    Sumerall, S W; Israel, A R; Brewer, R; Prew, R E

    1999-01-01

    With the rapid changes occurring in the American healthcare system, questions regarding various aspects of care have arisen. These changes have led to the need for individuals working within an Employee Assistance Program (EAP) to respond quickly and effectively to crisis situations. This article summarizes the different roles and responsibilities of EAP workers in the healthcare marketplace.

  14. A New Instrument for the IRTF: the MIT Optical Rapid Imaging System (MORIS)

    Science.gov (United States)

    Gulbis, Amanda A. S.; Elliot, J. L.; Rojas, F. E.; Bus, S. J.; Rayner, J. T.; Stahlberger, W. E.; Tokunaga, A. T.; Adams, E. R.; Person, M. J.

    2010-10-01

    NASA's 3-m Infrared Telescope Facility (IRTF) on Mauna Kea, HI plays a leading role in obtaining planetary science observations. However, there has been no capability for high-speed, visible imaging from this telescope. Here we present a new IRTF instrument, MORIS, the MIT Optical Rapid Imaging System. MORIS is based on POETS (Portable Occultation Eclipse and Transit Systems; Souza et al., 2006, PASP, 118, 1550). Its primary component is an Andor iXon camera, a 512x512 array of 16-micron pixels with high quantum efficiency, low read noise, low dark current, and full-frame readout rates of between 3.5 Hz (6 e /pixel read noise) and 35 Hz (49 e /pixel read noise at electron-multiplying gain=1). User-selectable binning and subframing can increase the cadence to a few hundred Hz. An electron-multiplying mode can be employed for photon counting, effectively reducing the read noise to sub-electron levels at the expense of dynamic range. Data cubes, or individual frames, can be triggered to nanosecond accuracy using a GPS. MORIS is mounted on the side-facing widow of SpeX (Rayner et al. 2003, PASP, 115, 362), allowing simultaneous near-infrared and visible observations. The mounting box contains 3:1 reducing optics to produce a 60 arcsec x 60 arcsec field of view at f/12.7. It hosts a ten-slot filter wheel, with Sloan g×, r×, i×, and z×, VR, Johnson V, and long-pass red filters. We describe the instrument design, components, and measured characteristics. We report results from the first science observations, a 24 June 2008 stellar occultation by Pluto. We also discuss a recent overhaul of the optical path, performed in order to eliminate scattered light. This work is supported in part by NASA Planetary Major Equipment grant NNX07AK95G. We are indebted to the University of Hawai'i Institute for Astronomy machine shop, in particular Randy Chung, for fabricating instrument components.

  15. Influence of platform screen doors on energy consumption of the environment control system of a mass rapid transit system: case study of the Taipei MRT [mass rapid transit] system

    Energy Technology Data Exchange (ETDEWEB)

    Shih-Cheng Hu; Jen-Ho Lee [National Taipei University of Technology, Taipei (China). Dept. of Air Conditioning and Refrigeration Engineering

    2004-03-01

    This investigation studies how platform screen doors (PSD) affect the energy consumption of the environmental control system of a mass rapid transit (MRT) system in Taipei. The environmental parameter simulation was conducted using the subway environmental simulation (SES) program, while the associated air conditioning (A/C) cooling load was predicted with the carrier E20-II program. Results show that PSD can significantly decrease average and peak cooling load, thus reducing the capacity/size of cooling equipment and allowing the chiller cooling load to be abridged. However, electricity consumption by ventilation equipment increases notably when PSD are used, particularly the electricity consumption by the under platform exhaust (UPE) fan, and thus, ultimately, little difference exists in the overall energy consumption with and without UPE. (author)

  16. The use of an automated flight test management system in the development of a rapid-prototyping flight research facility

    Science.gov (United States)

    Duke, Eugene L.; Hewett, Marle D.; Brumbaugh, Randal W.; Tartt, David M.; Antoniewicz, Robert F.; Agarwal, Arvind K.

    1988-01-01

    An automated flight test management system (ATMS) and its use to develop a rapid-prototyping flight research facility for artificial intelligence (AI) based flight systems concepts are described. The ATMS provides a flight test engineer with a set of tools that assist in flight planning and simulation. This system will be capable of controlling an aircraft during the flight test by performing closed-loop guidance functions, range management, and maneuver-quality monitoring. The rapid-prototyping flight research facility is being developed at the Dryden Flight Research Facility of the NASA Ames Research Center (Ames-Dryden) to provide early flight assessment of emerging AI technology. The facility is being developed as one element of the aircraft automation program which focuses on the qualification and validation of embedded real-time AI-based systems.

  17. Rapid supersensitive laser-semiconductor monitoring system. Time period covered: Dec. 15, 1993 - Dec. 15, 1994

    International Nuclear Information System (INIS)

    Pugatch, V.M.

    2001-01-01

    The creation of the rapid and sensitive system for the determination of the Alpha-radioactivity in the Environmental samples has been determined as the main goal of the Research Contract No. 7200RO/RB. As a result of the first stage of the research accomplished in the year 1993, the prototype of the system based on the combination of the laser photoionization mass spectrometry and many-channel alpha-spectrometer has been built and tested. To improve the sensitivity it was proposed to add one more stage to the laser photoionization mass-spectrometer. To develop the high position sensitivity of the system it was proposed to include into the alpha-radiometer SI strip-detector with submicron position sensitivity. Hardware and software for the laser-semiconductor monitoring system of alpha-radionuclides in the environment have been further developed and tested in frames of the IAEA Research Contract No. 7200/R1/RB. Optimization of the sample evaporation with one more stage of photoionization has been successfully performed in the laser photoionization mass-spectrometer. The automatization of the measurement procedure is under way by means of the IBM PC-386 and specially designed electronic units. The evaluated sensitivity of the new set-up is in the range of 1.0 Bq/kg. A bulk measurement of the alpha-radioactivity concentration in soil samples from the Chernobyl region (100 km) have been performed by means of thick samples method and built under this contract alpha-radiometer with large area SI semiconductor detectors. The lowest detectable level was in the range 100 Bq/kg without any radiochemical separation. Comparison with the data obtained for the same probes by means of the thin sample (with radiochemical separation) has shown higher Pu-concentration values obtained by means of the thick samples. For the first time the Sl-strip-detector with 128 channels has been applied for the alpha-radiometry purposes. Different read-out electronics (including the most

  18. Culture-Independent Techniques for Rapid Detection of Bacteria Associated with Loss of Chloramine Residual in a Drinking Water System

    OpenAIRE

    Hoefel, Daniel; Monis, Paul T.; Grooby, Warwick L.; Andrews, Stuart; Saint, Christopher P.

    2005-01-01

    Chloramination is often the disinfection regimen of choice for extended drinking water systems. However, this process is prone to instability due to the growth of nitrifying bacteria. This is the first study to use alternative approaches for rapid investigation of chloraminated drinking water system instability in which flow cytometric cell sorting of bacteria with intact membranes (membrane-intact fraction) (BacLight kit) or with active esterases (esterase-active fraction) (carboxyfluorescei...

  19. Rapid on-site monitoring of Legionella pneumophila in cooling tower water using a portable microfluidic system.

    Science.gov (United States)

    Yamaguchi, Nobuyasu; Tokunaga, Yusuke; Goto, Satoko; Fujii, Yudai; Banno, Fumiya; Edagawa, Akiko

    2017-06-08

    Legionnaires' disease, predominantly caused by the bacterium Legionella pneumophila, has increased in prevalence worldwide. The most common mode of transmission of Legionella is inhalation of contaminated aerosols, such as those generated by cooling towers. Simple, rapid and accurate methods to enumerate L. pneumophila are required to prevent the spread of this organism. Here, we applied a microfluidic device for on-chip fluorescent staining and semi-automated counting of L. pneumophila in cooling tower water. We also constructed a portable system for rapid on-site monitoring and used it to enumerate target bacterial cells rapidly flowing in the microchannel. A fluorescently-labelled polyclonal antibody was used for the selective detection of L. pneumophila serogroup 1 in the samples. The counts of L. pneumophila in cooling tower water obtained using the system and fluorescence microscopy were similar. The detection limit of the system was 10 4  cells/ml, but lower numbers of L. pneumophila cells (10 1 to 10 3  cells/ml) could be detected following concentration of 0.5-3 L of the water sample by filtration. Our technique is rapid to perform (1.5 h), semi-automated (on-chip staining and counting), and portable for on-site measurement, and it may therefore be effective in the initial screening of Legionella contamination in freshwater.

  20. Rapid assessment of infrastructure of primary health care facilities - a relevant instrument for health care systems management.

    Science.gov (United States)

    Scholz, Stefan; Ngoli, Baltazar; Flessa, Steffen

    2015-05-01

    Health care infrastructure constitutes a major component of the structural quality of a health system. Infrastructural deficiencies of health services are reported in literature and research. A number of instruments exist for the assessment of infrastructure. However, no easy-to-use instruments to assess health facility infrastructure in developing countries are available. Present tools are not applicable for a rapid assessment by health facility staff. Therefore, health information systems lack data on facility infrastructure. A rapid assessment tool for the infrastructure of primary health care facilities was developed by the authors and pilot-tested in Tanzania. The tool measures the quality of all infrastructural components comprehensively and with high standardization. Ratings use a 2-1-0 scheme which is frequently used in Tanzanian health care services. Infrastructural indicators and indices are obtained from the assessment and serve for reporting and tracing of interventions. The tool was pilot-tested in Tanga Region (Tanzania). The pilot test covered seven primary care facilities in the range between dispensary and district hospital. The assessment encompassed the facilities as entities as well as 42 facility buildings and 80 pieces of technical medical equipment. A full assessment of facility infrastructure was undertaken by health care professionals while the rapid assessment was performed by facility staff. Serious infrastructural deficiencies were revealed. The rapid assessment tool proved a reliable instrument of routine data collection by health facility staff. The authors recommend integrating the rapid assessment tool in the health information systems of developing countries. Health authorities in a decentralized health system are thus enabled to detect infrastructural deficiencies and trace the effects of interventions. The tool can lay the data foundation for district facility infrastructure management.

  1. A rapid radioassay for human IgG produced in lymphocyte in vitro culture systems

    International Nuclear Information System (INIS)

    Weightman, D.R.; Shale, D.J.; Tomlinson, W.R.

    1981-01-01

    Protein A bearing Staphylococcus aureus was used to develop a solid-phase radioassay for IgG immunoglobulins. The assay was specifically optimised for use in vitro human lymphocyte culture work. Compared with a solid-phase radioimmunoassay for IgG produced in lymphocyte culture, this assay had a similar performance profile and the advantages of rapidity and technical ease. (Auth.)

  2. Development of flexural vibration inspection techniques to rapidly assess the structural health of rural bridge systems

    Science.gov (United States)

    Brian K. Brashaw; Robert Vatalaro; Xiping Wang; Kevin Sarvela; James P. Wacker

    2008-01-01

    Approximately 4,000 vehicle bridges in the State of Minnesota contain structural timber members. Recent research at the University of Minnesota Duluth Natural Resources Research Institute (UMD NRRI) has been conducted on vibration testing of timber bridges as a means of developing rapid in-place testing techniques for assessing the structural health of bridges. The...

  3. Assessment of Arteriovenous Shunt Pathway Function and Hypervolemia for Hemodialysis Patients by Using Integrated Rapid Screening System

    Directory of Open Access Journals (Sweden)

    Wei-Ling Chen

    2017-06-01

    Full Text Available Currently, the hemodialysis patients received body weight measurement by themselves, vital sign checking by nursing staffs before dialysis. Whenever, the arteriovenous routes with problems doubted, the patients needed to be referred to surgeon for vascular echography checking and then to be corrected. How to integrate these three tasks in one time is a very important issue. The project proposes to combine our previous study of audio-phono angiographic technology in detecting vascular stenosis with rapid screening system to evaluate dialysis patients’ arteriovenous routes function and their status of excess body fluids: inspecting and integrating the blood pressure, body weight, and fistula function work into a rapid screening system, and using the quantization of fistula phono angiography pitch to achieve assessing arteriovenous routes. Future hoping is developed a complete integrated intelligence system by combining the arteriovenous fistula signal processing with feature extraction with wireless sensor network technology.

  4. Threshold and resilience management of coupled urbanization and water environmental system in the rapidly changing coastal region

    International Nuclear Information System (INIS)

    Li, Yangfan; Li, Yi; Wu, Wei

    2016-01-01

    The concept of thresholds shows important implications for environmental and resource management. Here we derived potential landscape thresholds which indicated abrupt changes in water quality or the dividing points between exceeding and failing to meet national surface water quality standards for a rapidly urbanizing city on the Eastern Coast in China. The analysis of landscape thresholds was based on regression models linking each of the seven water quality variables to each of the six landscape metrics for this coupled land-water system. We found substantial and accelerating urban sprawl at the suburban areas between 2000 and 2008, and detected significant nonlinear relations between water quality and landscape pattern. This research demonstrated that a simple modeling technique could provide insights on environmental thresholds to support more-informed decision making in land use, water environmental and resilience management. - Graphical abstract: Fig. Threshold models and resilience management for water quality. Display Omitted - Highlights: • Coupling urbanization and water environmental system. • Developing threshold models of the coupled land-water systems. • Nonlinear relations between water quality variables and landscape metrics. • Enhancing resilience management of coastal rapid urbanization. - We develop environmental threshold models and provide their implications on resilience management for a coupled land-water system with rapid urbanization.

  5. Monorail Piccolino catheter: a new rapid exchange/ultralow profile coronary angioplasty system.

    Science.gov (United States)

    Mooney, M R; Douglas, J S; Mooney, J F; Madison, J D; Brandenburg, R O; Fernald, R; Van Tassel, R A

    1990-06-01

    The Monorail Piccolino coronary angioplasty balloon catheter (MBC) was evaluated on 118 patients at two centers. Technical success was achieved in 110 patients (93%). Time for catheter exchange and total fluoroscopy time were significantly lower for the Monorail catheter than with standard equipment (exchange time 97 vs. 170 seconds P less than .05 and fluoroscopy time 17 vs. 88 seconds P less than .001). The advantages of rapid exchange and the ability of utilize 2 Monorail balloon catheters through one 9F guiding catheter for simultaneous inflations allowed for maximal flexibility in treating patients with bifurcation lesions. The double wire approach utilizing one Monorail balloon catheter with a 7F guiding catheter was also technically successful. The Monorail Piccolino balloon catheter has unique features that allow for greater ease of operator use, rapid catheter exchange, and optimal angiographic visualization. It is felt that this catheter design provides distinct advantages over standard angioplasty equipment.

  6. Rapid diagnosis of equine influenza by highly sensitive silver amplification immunochromatography system.

    Science.gov (United States)

    Yamanaka, Takashi; Nemoto, Manabu; Bannai, Hiroshi; Tsujimura, Koji; Kondo, Takashi; Matsumura, Tomio; Fu, Tao Qi Huang; Fernandez, Charlene Judith; Gildea, Sarah; Cullinane, Ann

    2017-06-16

    Equine influenza (EI) is a respiratory disease caused by equine influenza A virus (EIV, H3N8) infection. Rapid diagnosis is essential to limit the disease spread. We previously reported that some rapid antigen detection (RAD) tests are fit for diagnosing EI although their sensitivity is not optimal. Here, we evaluated the performance of the newly developed RAD test using silver amplification immunochromatography (Quick Chaser Auto Flu A, B: QCA) to diagnose EI. The detection limits of QCA for EIVs were five-fold lower than the conventional RAD tests. The duration of virus antigen detection in the infected horses was longer than the conventional RAD tests. We conclude that QCA could be a valuable diagnostic method for EI.

  7. Rapid prototyping of complete systems, the case study of a smart parking

    OpenAIRE

    Ducreux , Laurent-Frédéric; Guyon-Gardeux , Claire; Louvel , Maxime; Pacull , François; Safietou Raby , Thior; Vergara-Gallego , Maria Isabel

    2015-01-01

    International audience; This paper details how LINC a coordination middle-ware, can fasten the development of prototypes that integrate several equipment. A case study of rapid prototyping is presented. It illustrates how a smart parking prototype has been built from several independent and autonomous equipment, coming from different vendors. This has been achieved by parallel development thanks to the resource based approach offered by LINC. This paper also describes how LINC helps building ...

  8. A rapid method for establishment of a reverse genetics system for canine parvovirus.

    Science.gov (United States)

    Yu, Yongle; Su, Jun; Wang, Jigui; Xi, Ji; Mao, Yaping; Hou, Qiang; Zhang, Xiaomei; Liu, Weiquan

    2017-12-01

    Canine parvovirus (CPV) is an important and highly prevalent pathogen of dogs that causes acute hemorrhagic enteritis disease. Here, we describe a rapid method for the construction and characterization of a full-length infectious clone (rCPV) of CPV. Feline kidney (F81) cells were transfected with rCPV incorporating an engineered EcoR I site that served as a genetic marker. The rescued virus was indistinguishable from that of wild-type virus in its biological properties.

  9. The influence of wavelength-dependent radiation in simulation of lamp-heated rapid thermal processing systems

    Energy Technology Data Exchange (ETDEWEB)

    Ting, A. [Sandia National Labs., Livermore, CA (United States). Computational Mechanics Dept.

    1994-08-01

    Understanding the thermal response of lamp-heated rapid thermal processing (RTP) systems requires understanding relatively complex radiation exchange among opaque and partially transmitting surfaces and materials. The objective of this paper is to investigate the influence of wavelength-dependent radiative properties. The examples used for the analysis consider axisymmetric systems of the kind that were developed by Texas Instruments (TI) for the Microelectronics Manufacturing Science and Technology (MMST) Program and illustrate a number of wavelength-dependent (spectral) effects. The models execute quickly on workstation class computing flatforms, and thus permit rapid comparison of alternative reactor designs and physical models. The fast execution may also permit the incorporation of these models into real-time model-based process control algorithms.

  10. A Fluorescent Tile DNA Diagnocode System for In Situ Rapid and Selective Diagnosis of Cytosolic RNA Cancer Markers

    Science.gov (United States)

    Park, Kyung Soo; Shin, Seung Won; Jang, Min Su; Shin, Woojung; Yang, Kisuk; Min, Junhong; Cho, Seung-Woo; Oh, Byung-Keun; Bae, Jong Wook; Jung, Sunghwan; Choi, Jeong-Woo; Um, Soong Ho

    2015-01-01

    Accurate cancer diagnosis often requires extraction and purification of genetic materials from cells, and sophisticated instrumentations that follow. Otherwise in order to directly treat the diagnostic materials to cells, multiple steps to optimize dose concentration and treatment time are necessary due to diversity in cellular behaviors. These processes may offer high precision but hinder fast analysis of cancer, especially in clinical situations that need rapid detection and characterization of cancer. Here we present a novel fluorescent tile DNA nanostructure delivered to cancer cytosol by employing nanoparticle technology. Its structural anisotropicity offers easy manipulation for multifunctionalities, enabling the novel DNA nanostructure to detect intracellular cancer RNA markers with high specificity within 30 minutes post treatment, while the nanoparticle property bypasses the requirement of treatment optimization, effectively reducing the complexity of applying the system for cancer diagnosis. Altogether, the system offers a precise and rapid detection of cancer, suggesting the future use in the clinical fields. PMID:26678430

  11. Identification of Staphylococcus species and subspecies with the MicroScan Pos ID and Rapid Pos ID panel systems.

    Science.gov (United States)

    Kloos, W E; George, C G

    1991-01-01

    The accuracies of the MicroScan Pos ID and Rapid Pos ID panel systems (Baxter Diagnostic Inc., MicroScan Division, West Sacramento, Calif.) were compared with each other and with the accuracies of conventional methods for the identification of 25 Staphylococcus species and 4 subspecies. Conventional methods included those used in the original descriptions of species and subspecies and DNA-DNA hybridization. The Pos ID panel uses a battery of 18 tests, and the Rapid Pos ID panel uses a battery of 42 tests for the identification of Staphylococcus species. The Pos ID panel has modified conventional and chromogenic tests that can be read after 15 to 48 h of incubation; the Rapid Pos ID panel has tests that use fluorogenic substrates or fluorometric indicators, and test results can be read after 2 h of incubation in the autoSCAN-W/A. Results indicated that both MicroScan systems had a high degree of congruence (greater than or equal to 90%) with conventional methods for the species S. capitis, S. aureus, S. auricularis, S. saprophyticus, S. cohnii, S. arlettae, S. carnosus, S. lentus, and S. sciuri and, in particular, the subspecies S. capitis subsp. capitis and S. cohnii subsp. cohnii. The Rapid Pos ID panel system also had greater than or equal to 90% congruence with conventional methods for S. epidermidis, S. caprae, S. warneri subsp. 2, S. xylosus, S. kloosii, and S. caseolyticus. For both MicroScan systems, congruence with conventional methods was 80 to 90% for S. haemolyticus subsp. 1, S. equorum, S. intermedius, and S. hyicus; and in addition, with the Rapid Pos ID panel system congruence was 80 to 89% for S. capitis subsp. ureolyticus, S. warneri subsp. 1, S. hominis, S. cohnii subsp. urealyticum, and S. simulans. The MicroScan systems identified a lower percentage (50 to 75%) of strains of S. lugdunensis, S. gallinarum, S. schleiferi, and S. chromogenes, although the addition of specific tests to the systems might increase the accuracy of identification

  12. Rapid breeding and varietal replacement are critical to adaptation of cropping systems in the developing world to climate change.

    Science.gov (United States)

    Atlin, Gary N; Cairns, Jill E; Das, Biswanath

    2017-03-01

    Plant breeding is a key mechanism for adaptation of cropping systems to climate change. Much discussion of breeding for climate change focuses on genes with large effects on heat and drought tolerance, but phenology and stress tolerance are highly polygenic. Adaptation will therefore mainly result from continually adjusting allele frequencies at many loci through rapid-cycle breeding that delivers a steady stream of incrementally improved cultivars. This will require access to elite germplasm from other regions, shortened breeding cycles, and multi-location testing systems that adequately sample the target population of environments. The objective of breeding and seed systems serving smallholder farmers should be to ensure that they use varieties developed in the last 10 years. Rapid varietal turnover must be supported by active dissemination of new varieties, and active withdrawal of obsolete ones. Commercial seed systems in temperate regions achieve this through competitive seed markets, but in the developing world, most crops are not served by competitive commercial seed systems, and many varieties date from the end of the Green Revolution (the late 1970s, when the second generation of modern rice and wheat varieties had been widely adopted). These obsolete varieties were developed in a climate different than today's, placing farmers at risk. To reduce this risk, a strengthened breeding system is needed, with freer international exchange of elite varieties, short breeding cycles, high selection intensity, wide-scale phenotyping, and accurate selection supported by genomic technology. Governments need to incentivize varietal release and dissemination systems to continuously replace obsolete varieties.

  13. On-site identification of meat species in processed foods by a rapid real-time polymerase chain reaction system.

    Science.gov (United States)

    Furutani, Shunsuke; Hagihara, Yoshihisa; Nagai, Hidenori

    2017-09-01

    Correct labeling of foods is critical for consumers who wish to avoid a specific meat species for religious or cultural reasons. Therefore, gene-based point-of-care food analysis by real-time Polymerase Chain Reaction (PCR) is expected to contribute to the quality control in the food industry. In this study, we perform rapid identification of meat species by our portable rapid real-time PCR system, following a very simple DNA extraction method. Applying these techniques, we correctly identified beef, pork, chicken, rabbit, horse, and mutton in processed foods in 20min. Our system was sensitive enough to detect the interfusion of about 0.1% chicken egg-derived DNA in a processed food sample. Our rapid real-time PCR system is expected to contribute to the quality control in food industries because it can be applied for the identification of meat species, and future applications can expand its functionality to the detection of genetically modified organisms or mutations. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. The national web-based outbreak rapid alert system in Norway: eight years of experience, 2006-2013.

    Science.gov (United States)

    Guzman-Herrador, B; Vold, L; Berg, T; Berglund, T M; Heier, B; Kapperud, G; Lange, H; Nygård, K

    2016-01-01

    In 2005, the Norwegian Institute of Public Health established a web-based outbreak rapid alert system called Vesuv. The system is used for mandatory outbreak alerts from municipal medical officers, healthcare institutions, and food safety authorities. As of 2013, 1426 outbreaks have been reported, involving 32913 cases. More than half of the outbreaks occurred in healthcare institutions (759 outbreaks, 53·2%). A total of 474 (33·2%) outbreaks were associated with food or drinking water. The web-based rapid alert system has proved to be a helpful tool by enhancing reporting and enabling rapid and efficient information sharing between different authorities at both the local and national levels. It is also an important tool for event-based reporting, as required by the International Health Regulations (IHR) 2005. Collecting information from all the outbreak alerts and reports in a national database is also useful for analysing trends, such as occurrence of certain microorganisms, places or sources of infection, or route of transmission. This can facilitate the identification of specific areas where more general preventive measures are needed.

  15. Rapid Learning health care in oncology’ – An approach towards decision support systems enabling customised radiotherapy’

    International Nuclear Information System (INIS)

    Lambin, Philippe; Roelofs, Erik; Reymen, Bart; Velazquez, Emmanuel Rios; Buijsen, Jeroen; Zegers, Catharina M.L.; Carvalho, Sara; Leijenaar, Ralph T.H.; Nalbantov, Georgi; Oberije, Cary; Scott Marshall, M.; Hoebers, Frank; Troost, Esther G.C.; Stiphout, Ruud G.P.M. van; Elmpt, Wouter van; Weijden, Trudy van der; Boersma, Liesbeth; Valentini, Vincenzo; Dekker, Andre

    2013-01-01

    Purpose: An overview of the Rapid Learning methodology, its results, and the potential impact on radiotherapy. Material and results: Rapid Learning methodology is divided into four phases. In the data phase, diverse data are collected about past patients, treatments used, and outcomes. Innovative information technologies that support semantic interoperability enable distributed learning and data sharing without additional burden on health care professionals and without the need for data to leave the hospital. In the knowledge phase, prediction models are developed for new data and treatment outcomes by applying machine learning methods to data. In the application phase, this knowledge is applied in clinical practice via novel decision support systems or via extensions of existing models such as Tumour Control Probability models. In the evaluation phase, the predictability of treatment outcomes allows the new knowledge to be evaluated by comparing predicted and actual outcomes. Conclusion: Personalised or tailored cancer therapy ensures not only that patients receive an optimal treatment, but also that the right resources are being used for the right patients. Rapid Learning approaches combined with evidence based medicine are expected to improve the predictability of outcome and radiotherapy is the ideal field to study the value of Rapid Learning. The next step will be to include patient preferences in the decision making

  16. CO2-laser micromachining and back-end processing for rapid production of PMMA-based microfluidic systems

    DEFF Research Database (Denmark)

    Klank, Henning; Kutter, Jörg Peter; Geschke, Oliver

    2002-01-01

    , a three-layer polymer microstructure with included optical fibers was fabricated within two days. The use of CO2-laser systems to produce microfluidic systems has not been published before. These systems provide a cost effective alternative to UV-laser systems and they are especially useful......In this article, we focus on the enormous potential of a CO2-laser system for rapidly producing polymer microfluidic structures. The dependence was assessed of the depth and width of laser-cut channels on the laser beam power and on the number of passes of the beam along the same channel...... for microstructured PMMA [poly( methyl methacrylate)] parts were investigated, such as solvent-assisted glueing, melting, laminating and surface activation using a plasma asher. A solvent-assisted thermal bonding method proved to be the most time-efficient one. Using laser micromachining together with bonding...

  17. Performance of a Micro-UAV lifting system built with the usage of rapid prototyping methods

    International Nuclear Information System (INIS)

    Dalewski, R T; Gumowski, K; Barczak, T; Godek, J

    2014-01-01

    This article presents results of the aerodynamic testing of a micro unmanned aerial vehicle rotor efficiency. The rotors were prepared as a set of two rotors in a counter-rotating ducted drive. Prototypes of the drives were made using two rapid prototyping techniques – FDM – fused deposition modelling method and SLS – selective laser sintering. Rotors were made then treated by introducing additional finishing cyanoacrylate coating and abrasive processing. Main differences between those models were observed in fan shape, porosity, surface roughness and mechanical properties – stiffness. An influence of these factors was observed on an aerodynamic efficiency. For the obtained prototypes both simulations and experimental testing were conducted with thrust, power, torque measurements, as well as the measurement of velocity and pressure distribution at the outlet of the duct. The results show the possibility of using rapid prototyping techniques to produce prototypes of drives operating in the low and medium Reynolds numbers (6000-60000), and the aerodynamic shape relevant factors affecting the preparation and performance of such drives. In addition, simulation studies were performed using the Fluent environment where experimental results were confronted with the results of simulation studies.

  18. High permeation rates in liposome systems explain rapid glyphosate biodegradation associated with strong isotope fractionation.

    Science.gov (United States)

    Ehrl, Benno; Mogusu, Emmanuel O; Kim, Kyoungtea; Hofstetter, Heike; Pedersen, Joel A; Elsner, Martin

    2018-05-23

    Bacterial uptake of charged organic pollutants such as the widely used herbicide glyphosate is typically attributed to active transporters, whereas passive membrane permeation as an uptake pathway is usually neglected. For 1-palmitoyl-2-oleoyl-sn-glycero-3-phosphocholine (POPC) liposomes, pH-dependent membrane permeation coefficients (Papp) of glyphosate, determined by nuclear magnetic resonance (NMR) spectroscopy, varied from Papp(pH 7.0) = 3.7 (+/-0.3) × 10-7 m∙s-1 to Papp(pH 4.1) = 4.2 (+/-0.1) × 10-6 m∙s-1. This surprisingly rapid membrane permeation depended on glyphosate speciation and was, at physiological pH, in the range of polar, non-charged molecules suggesting that passive membrane permeation is a potential uptake pathway during glyphosate biodegradation. To test this hypothesis, a Gram-negative glyphosate degrader, Ochrobactrum sp. FrEM, was isolated from glyphosate-treated soil and glyphosate permeation rates inferred from the liposome model were compared to bacterial degradation rates. Estimated maximum permeation rates were, indeed, two orders of magnitudes higher than glyphosate degradation rates. Moreover, biodegradation of millimolar glyphosate concentrations gave rise to pronounced carbon isotope fractionation with an apparent kinetic isotope effect of AKIEcarbon= 1.014 ± 0.003. This value is consistent with unmasked enzymatic isotope fractionation demonstrating that glyphosate biodegradation was little mass transfer-limited and glyphosate exchange across the cell membrane was rapid relative to enzymatic turnover.

  19. Automatic RST-based system for a rapid detection of man-made disasters

    Science.gov (United States)

    Tramutoli, Valerio; Corrado, Rosita; Filizzola, Carolina; Livia Grimaldi, Caterina Sara; Mazzeo, Giuseppe; Marchese, Francesco; Pergola, Nicola

    2010-05-01

    Man-made disasters may cause injuries to citizens and damages to critical infrastructures. When it is not possible to prevent or foresee such disasters it is hoped at least to rapidly detect the accident in order to intervene as soon as possible to minimize damages. In this context, the combination of a Robust Satellite Technique (RST), able to identify for sure actual (i.e. no false alarm) accidents, and satellite sensors with high temporal resolution seems to assure both a reliable and a timely detection of abrupt Thermal Infrared (TIR) transients related to dangerous explosions. A processing chain, based on the RST approach, has been developed in the framework of the GMOSS and G-MOSAIC projects by DIFA-UNIBAS team, suitable for automatically identify on MSG-SEVIRI images harmful events. Maps of thermal anomalies are generated every 15 minutes (i.e. SEVIRI temporal repetition rate) over a selected area together with kml files (containing information on latitude and longitude of "thermally" anomalous SEVIRI pixel centre, time of image acquisition, relative intensity of anomalies, etc.) for a rapid visualization of the accident position even on Google Earth. Results achieved in the cases of gas pipelines recently exploded or attacked in Russia and in Iraq will be presented in this work.

  20. Influence of platform screen doors on energy consumption of the environment control system of a mass rapid transit system: case study of the Taipei MRT system

    International Nuclear Information System (INIS)

    Hu, S.-C.; Lee, J.-H.

    2004-01-01

    This investigation studies how platform screen doors (PSD) affect the energy consumption of the environmental control system of a mass rapid transit (MRT) system in Taipei. The environmental parameter simulation was conducted using the subway environmental simulation (SES) program, while the associated air conditioning (A/C) cooling load was predicted with the carrier E20-II program. Results show that PSD can significantly decrease average and peak cooling load, thus reducing the capacity/size of cooling equipment and allowing the chiller cooling load to be abridged. However, electricity consumption by ventilation equipment increases notably when PSD are used, particularly the electricity consumption by the under platform exhaust (UPE) fan, and thus, ultimately, little difference exists in the overall energy consumption with and without UPE

  1. Influence of platform screen doors on energy consumption of the environment control system of a mass rapid transit system: case study of the Taipei MRT system

    Energy Technology Data Exchange (ETDEWEB)

    Hu, S.-C. E-mail: f10870@ntut.edu.tw; Lee, J.-H

    2004-03-01

    This investigation studies how platform screen doors (PSD) affect the energy consumption of the environmental control system of a mass rapid transit (MRT) system in Taipei. The environmental parameter simulation was conducted using the subway environmental simulation (SES) program, while the associated air conditioning (A/C) cooling load was predicted with the carrier E20-II program. Results show that PSD can significantly decrease average and peak cooling load, thus reducing the capacity/size of cooling equipment and allowing the chiller cooling load to be abridged. However, electricity consumption by ventilation equipment increases notably when PSD are used, particularly the electricity consumption by the under platform exhaust (UPE) fan, and thus, ultimately, little difference exists in the overall energy consumption with and without UPE.

  2. Process Modelling of Rapid Manufacturing Based Mass Customisation System for Fabrication of Custom Foot Orthoses: Review Paper

    Directory of Open Access Journals (Sweden)

    Saleh Jumani

    2013-04-01

    Full Text Available The need for custom-made devices, rehabilitation aids and treatments is explicit in the medical sector. Applications of rapid manufacturing techniques based on additive fabrication processes combined with medical digitising technologies can generate high quality solutions in situations where the need for custom-made devices and rehabilitation aids and low-lead times are very important factors. Foot orthoses are medical devices applied in the treatment of biomechanical foot disorders, foot injuries and foot diseases including rheumatoid arthritis and diabetes. The significant challenge in the treatment of foot related diseases is progressing pathological deterioration in the affected sites of the foot which requires quick provision of the orthoses. A process model is developed using the IDEF0 modelling technique in which a rapid manufacturing approach is integrated in the design and fabrication process of custom foot orthoses. The process model will be used in the development of rapid manufacturing based design and fabrication system for mass customisation of foot orthoses. The developed system is aimed at mass scale production of custom foot orthoses with the advantages of reduced cost, reduced lead-time and improved product in terms of increased fit, consistency and accuracy in the final product.

  3. An improved out-cell to in-cell rapid transfer system at the HFEF-south

    International Nuclear Information System (INIS)

    Bacca, J.P.; Sherman, E.K.

    1990-01-01

    The Argonne National Laboratory (ANL) Hot Fuel Examination Facility-South (HFEF-S), located at the ANL-West site of the Idaho National Engineering Laboratory, is currently undergoing extensive refurbishment and modifications in preparation for its use, beginning in 1991, in demonstrating remote recycling of fast reactor, metal-alloy fuel as part of the US Department of Energy liquid-metal reactor, Integral Fast Reactor (IFR) program. Included in these improvements to HFEF-S is a new, small-item, rapid transfer system (RTS). When installed, this system will enable the rapid transfer of small items from the hot-cell exterior into the argon cell (argon-gas atmosphere) of the facility without necessitating the use of time-consuming and laborious procedures. The new RTS will also provide another important function associated with HFEF-S hot-cell operation in the IFR Fuel Recycle Program; namely, the rapid insertion of clean, radioactive contamination-measuring smear paper specimens into the hot cells for area surveys, and the expedited removal of these contaminated (including alpha as well as beta/gamma contamination) smears from the argon cell for transfer to an adjacent health physics field laboratory in the facility for nuclear contamination/radiation counting

  4. Comparison of four methods for rapid identification of Staphylococcus aureus directly from BACTEC 9240 blood culture system

    Directory of Open Access Journals (Sweden)

    N S Ozen

    2011-01-01

    Full Text Available Purpose: Differentiation of Staphylococcus aureus (S. aureus from coagulase-negative staphylococci is very important in blood stream infections. Identification of S. aureus and coagulase-negative staphylococci (CoNS from blood cultures takes generally 18-24 h after positive signaling on continuously monitored automated blood culture system. In this study, we evaluated the performance of tube coagulase test (TCT, slide agglutination test (Dry Spot Staphytect Plus, conventional polymerase chain reaction (PCR and LightCycler Staphylococcus MGrade kit directly from blood culture bottles to achieve rapid identification of S. aureus by using the BACTEC 9240 blood culture system. Materials and Methods: A total of 129 BACTEC 9240 bottles growing gram-positive cocci suggesting Staphylococci were tested directly from blood culture broths (BCBs with TCT, Dry Spot Staphytect Plus, conventional PCR and LightCycler Staphylococcus MGrade kit for rapid identification of S. aureus. Results: The sensitivities of the tests were 99, 68, 99 and 100%, respectively. Conclusion: Our results suggested that 2 h TCT was found to be simple and inexpensive method for the rapid identification of S. aureus directly from positive blood cultures.

  5. Comparison of four methods for rapid identification of Staphylococcus aureus directly from BACTEC 9240 blood culture system.

    Science.gov (United States)

    Ozen, N S; Ogunc, D; Mutlu, D; Ongut, G; Baysan, B O; Gunseren, F

    2011-01-01

    Differentiation of Staphylococcus aureus (S. aureus) from coagulase-negative staphylococci is very important in blood stream infections. Identification of S. aureus and coagulase-negative staphylococci (CoNS) from blood cultures takes generally 18-24 h after positive signaling on continuously monitored automated blood culture system. In this study, we evaluated the performance of tube coagulase test (TCT), slide agglutination test (Dry Spot Staphytect Plus), conventional polymerase chain reaction (PCR) and LightCycler Staphylococcus MGrade kit directly from blood culture bottles to achieve rapid identification of S. aureus by using the BACTEC 9240 blood culture system. A total of 129 BACTEC 9240 bottles growing gram-positive cocci suggesting Staphylococci were tested directly from blood culture broths (BCBs) with TCT, Dry Spot Staphytect Plus, conventional PCR and LightCycler Staphylococcus MGrade kit for rapid identification of S. aureus. The sensitivities of the tests were 99, 68, 99 and 100%, respectively. Our results suggested that 2 h TCT was found to be simple and inexpensive method for the rapid identification of S. aureus directly from positive blood cultures.

  6. Clinical laboratory evaluation of the Auto-Microbic system for rapid identification of Enterobacteriaceae.

    OpenAIRE

    Hasyn, J J; Cundy, K R; Dietz, C C; Wong, W

    1981-01-01

    The capability of the Auto-Microbic system (Vitek Systems, Inc., Hazelwood, Mo.) has been expanded to identify members of the family Enterobacteriaceae with the use of a sealed, disposable accessory card (the Enterobacteriaceae Biochemical Card) containing 26 biochemical tests. To judge the accuracy of the AutoMicrobic system's identification in a hospital laboratory, 933 Enterobacteriaceae isolates were studied. The AutoMicrobic system provided the correct identification for 905 of the isola...

  7. Rapidly reconfigurable slow-light system based on off-resonant Raman absorption

    International Nuclear Information System (INIS)

    Vudyasetu, Praveen K.; Howell, John C.; Camacho, Ryan M.

    2010-01-01

    We present a slow-light system based on dual Raman absorption resonances in warm rubidium vapor. Each Raman absorption resonance is produced by a control beam in an off-resonant Λ system. This system combines all optical control of the Raman absorption and the low-dispersion broadening properties of the double Lorentzian absorption slow light. The bandwidth, group delay, and central frequency of the slow-light system can all be tuned dynamically by changing the properties of the control beam. We demonstrate multiple pulse delays with low distortion and show that such a system has fast switching dynamics and thus fast reconfiguration rates.

  8. ScreenCube: A 3D Printed System for Rapid and Cost-Effective Chemical Screening in Adult Zebrafish.

    Science.gov (United States)

    Monstad-Rios, Adrian T; Watson, Claire J; Kwon, Ronald Y

    2018-02-01

    Phenotype-based small molecule screens in zebrafish embryos and larvae have been successful in accelerating pathway and therapeutic discovery for diverse biological processes. Yet, the application of chemical screens to adult physiologies has been relatively limited due to additional demands on cost, space, and labor associated with screens in adult animals. In this study, we present a 3D printed system and methods for intermittent drug dosing that enable rapid and cost-effective chemical administration in adult zebrafish. Using prefilled screening plates, the system enables dosing of 96 fish in ∼3 min, with a 10-fold reduction in drug quantity compared to that used in previous chemical screens in adult zebrafish. We characterize water quality kinetics during immersion in the system and use these kinetics to rationally design intermittent dosing regimens that result in 100% fish survival. As a demonstration of system fidelity, we show the potential to identify two known chemical inhibitors of adult tail fin regeneration, cyclopamine and dorsomorphin. By developing methods for rapid and cost-effective chemical administration in adult zebrafish, this study expands the potential for small molecule discovery in postembryonic models of development, disease, and regeneration.

  9. An improved out-cell to in-cell rapid transfer system at the HFEF/South

    International Nuclear Information System (INIS)

    Bacca, J.P.; Sherman, E.K.

    1991-01-01

    This paper reports on Argonne National Laboratory's Fuel Cycle Facility (FCF) (formerly named Hot Fuel Examination Facility-South) (HFEF/South) which is currently being refurbished and upgraded in preparation for demonstrating remote, fast reactor metal-fuel reprocessing and refabrication, as part of the Integral Fast Reactor (IFR) Program. Among the FCF hot-cell system upgrades being provided is a newly fabricated, direct, out-of-cell to in-cell, small-item transfer system for the FCF argon cell. This system will enable the rapid transfer of selected small items from the hot cell exterior into the argon cell (argon-gas atmosphere) of the facility, without necessitating the use of formerly employed, very time-consuming, and quite laborious procedures. The new system will be especially valuable for the rapid insertion of IFR fuel processing makeup materials and small tools into the argon cell, and for use in argon cell and overall FCF radioactive contamination-control activities

  10. Pneumatic control system for rapid vertical rectangular movements of heavy loads

    Energy Technology Data Exchange (ETDEWEB)

    Huettel, G; Krause, H [Zentralinstitut fuer Kernforschung, Rossendorf bei Dresden (German Democratic Republic)

    1975-01-01

    A new control system has been developed in order to realize the physically necessary short transition times between the dead points of a pneumatic oscillator even for heavy loads and high working speeds. Integral element of this system is the external control of braking process provided for in addition to the end position brake installed in the working cylinder. This control system is applicable not only to pile oscillators, but also universally applicable to pneumatic apparatuses.

  11. A pneumatic control system for rapid vertical rectangular movements of heavy loads

    International Nuclear Information System (INIS)

    Huettel, G.; Krause, H.

    1975-01-01

    A new control system has been developed in order to realize the physically necessary short transition times between the dead points of a pneumatic oscillator even for heavy loads and high working speeds. Integral element of this system is the external control of braking process provided for in addition to the end position brake installed in the working cylinder. This control system is applicable not only to pile oscillators, but also universally applicable to pneumatic apparatuses working like that. (author)

  12. Diurnal variation in the performance of rapid response systems: the role of critical care services-a review article.

    Science.gov (United States)

    Sundararajan, Krishnaswamy; Flabouris, Arthas; Thompson, Campbell

    2016-01-01

    The type of medical review before an adverse event influences patient outcome. Delays in the up-transfer of patients requiring intensive care are associated with higher mortality rates. Timely detection and response to a deteriorating patient constitute an important function of the rapid response system (RRS). The activation of the RRS for at-risk patients constitutes the system's afferent limb. Afferent limb failure (ALF), an important performance measure of rapid response systems, constitutes a failure to activate a rapid response team (RRT) despite criteria for calling an RRT. There are diurnal variations in hospital staffing levels, the performance of rapid response systems and patient outcomes. Fewer ward-based nursing staff at night may contribute to ALF. The diurnal variability in RRS activity is greater in unmonitored units than it is in monitored units for events that should result in a call for an RRT. RRT events include a significant abnormality in either the pulse rate, blood pressure, conscious state or respiratory rate. There is also diurnal variation in RRT summoning rates, with most activations occurring during the day. The reasons for this variation are mostly speculative, but the failure of the afferent limb of RRT activation, particularly at night, may be a factor. The term "circadian variation/rhythm" applies to physiological variations over a 24-h cycle. In contrast, diurnal variation applies more accurately to extrinsic systems. Circadian rhythm has been demonstrated in a multitude of bodily functions and disease states. For example, there is an association between disrupted circadian rhythms and abnormal vital parameters such as anomalous blood pressure, irregular pulse rate, aberrant endothelial function, myocardial infarction, stroke, sleep-disordered breathing and its long-term consequences of hypertension, heart failure and cognitive impairment. Therefore, diurnal variation in patient outcomes may be extrinsic, and more easily modifiable

  13. Video Feedforward for Rapid Learning of a Picture-Based Communication System

    Science.gov (United States)

    Smith, Jemma; Hand, Linda; Dowrick, Peter W.

    2014-01-01

    This study examined the efficacy of video self modeling (VSM) using feedforward, to teach various goals of a picture exchange communication system (PECS). The participants were two boys with autism and one man with Down syndrome. All three participants were non-verbal with no current functional system of communication; the two children had long…

  14. Development of a System for Rapid Detection of Contaminants in Water Supplies Using Magnetic Resonance and Nanoparticles

    Energy Technology Data Exchange (ETDEWEB)

    Lowery, Thomas J; Neely, Lori; Chepin, James; Wellman, Parris; Toso, Ken; Murray, Paul; Audeh, Mark; Demas, Vasiliki; Palazzolo, Robert; Min, Michael; Phung, Nu; Blanco, Matt; Raphel, Jordan; O' Neil, Troy

    2010-09-14

    To keep the water supply safe and to ensure a swift and accurate response to a water supply contamination event, rapid and robust methods for microbial testing are necessary. Current technologies are complex, lengthy and costly and there is a need for rapid, reliable, and precise approaches that can readily address this fundamental security and safety issue. T2 Biosystems is focused on providing solutions to this problem by making breakthroughs in nanotechnology and biosensor techniques that address the current technical restrictions facing rapid, molecular analysis in complex samples. In order to apply the T2 Biosystems nucleic acid detection procedure to the analysis of nucleic acid targets in unprocessed water samples, Bacillus thuringeinsis was selected as a model organism and local river water was selected as the sample matrix. The initial assay reagent formulation was conceived with a manual magnetic resonance reader, was optimized using a high throughput system, and transferred back to the MR reader for potential field use. The final assay employing the designed and manufactured instruments was capable of detecting 10 CFU/mL of B. thuringiensis directly within the environmental water sample within 90 minutes. Further, discrimination of two closely related species of Bacilli was accomplished using the methods of this project; greater than 3-fold discrimination between B. cereus and B. thuringiensis at a concentrations spanning 10 CFU/mL to 10{sup 5} CFU/mL was observed.

  15. Rapid Assessment of the Ce-Co-Fe-Cu System for Permanent Magnetic Applications

    Science.gov (United States)

    Meng, F.; Chaudhary, R. P.; Gandha, K.; Nlebedim, I. C.; Palasyuk, A.; Simsek, E.; Kramer, M. J.; Ott, R. T.

    2018-04-01

    This work focuses on the rapid synthesis and characterization of quaternary Ce(CoFeCu)5 alloy libraries to assess their potential viability as permanent magnets. Arrays of bulk specimens with controlled compositions were synthesized via laser engineered net shaping (LENS) by feeding different ratios of alloy powders into a melt pool created by a laser. Based on the assessment of the magnetic properties of the LENS printed samples, arc-melted and cast ingots were prepared with varying Fe (5-20 at.%) and Co (60-45 at.%) compositions while maintaining constant Ce (16 at.%) and Cu (19 at.%) content. The evolution of the microstructure and phases with varying chemical compositions and their dependence on magnetic properties are analyzed in as-cast and heat-treated samples. In both the LENS printed and cast samples, we find the best magnetic properties correspond to a predominantly single-phase Ce(CoFeCu)5 microstructure in which high coercivity (H c > 10 kOe) can be achieved without any microstructural refinement.

  16. Rapid determination of nanowires electrical properties using a dielectrophoresis-well based system

    Science.gov (United States)

    Constantinou, Marios; Hoettges, Kai F.; Krylyuk, Sergiy; Katz, Michael B.; Davydov, Albert; Rigas, Grigorios-Panagiotis; Stolojan, Vlad; Hughes, Michael P.; Shkunov, Maxim

    2017-03-01

    The use of high quality semiconducting nanomaterials for advanced device applications has been hampered by the unavoidable growth variability of electrical properties of one-dimensional nanomaterials, such as nanowires and nanotubes, thus highlighting the need for the characterization of efficient semiconducting nanomaterials. In this study, we demonstrate a low-cost, industrially scalable dielectrophoretic (DEP) nanowire assembly method for the rapid analysis of the electrical properties of inorganic single crystalline nanowires, by identifying key features in the DEP frequency response spectrum from 1 kHz to 20 MHz in just 60 s. Nanowires dispersed in anisole were characterized using a three-dimensional DEP chip (3DEP), and the resultant spectrum demonstrated a sharp change in nanowire response to DEP signal in 1-20 MHz frequency range. The 3DEP analysis, directly confirmed by field-effect transistor data, indicates that nanowires of higher quality are collected at high DEP signal frequency range above 10 MHz, whereas lower quality nanowires, with two orders of magnitude lower current per nanowire, are collected at lower DEP signal frequencies. These results show that the 3DEP platform can be used as a very efficient characterization tool of the electrical properties of rod-shaped nanoparticles to enable dielectrophoretic selective deposition of nanomaterials with superior conductivity properties.

  17. Evaluation of Rapid Stain IDentification (RSID™ Reader System for Analysis and Documentation of RSID™ Tests

    Directory of Open Access Journals (Sweden)

    Pravatchai W. Boonlayangoor

    2013-08-01

    Full Text Available The ability to detect the presence of body fluids is a crucial first step in documenting and processing forensic evidence. The Rapid Stain IDentification (RSID™ tests for blood, saliva, semen and urine are lateral flow immunochromatographic strip tests specifically designed for forensic use. Like most lateral flow strips, the membrane components of the test are enclosed in a molded plastic cassette with a sample well and an observation window. No specialized equipment is required to use these tests or to score the results seen in the observation window; however, the utility of these tests can be enhanced if an electronic record of the test results can be obtained, preferably by a small hand-held device that could be used in the field under low light conditions. Such a device should also be able to “read” the lateral flow strips and accurately record the results of the test as either positive, i.e., the body fluid was detected, or negative, i.e., the body fluid was not detected. Here we describe the RSID™ Reader System—a ruggedized strip test reader unit that allows analysis and documentation of RSID™ lateral flow strip tests using pre-configured settings, and show that the RSID™ Reader can accurately and reproducibly report and record correct results from RSID™ blood, saliva, semen, and urine tests.

  18. The role of the primary care team in the rapid response system.

    Science.gov (United States)

    O'Horo, John C; Sevilla Berrios, Ronaldo A; Elmer, Jennifer L; Velagapudi, Venu; Caples, Sean M; Kashyap, Rahul; Jensen, Jeffrey B

    2015-04-01

    The purpose of the study is to evaluate the impact of primary service involvement on rapid response team (RRT) evaluations. The study is a combination of retrospective chart review and prospective survey-based evaluation. Data included when and where the activations occurred and the patient's code status, primary service, and ultimate disposition. These data were correlated with survey data from each event. A prospective survey evaluated the primary team's involvement in decision making and the overall subjective quality of the interaction with primary service through a visual analog scale. We analyzed 4408 RRTs retrospectively and an additional 135 prospectively. The primary team's involvement by telephone or in person was associated with significantly more transfers to higher care levels in retrospective (P team involvement, with more frequent changes seen in the retrospective analysis (P = .01). Subjective ratings of communication by the RRT leader were significantly higher when the primary service was involved (P team involvement influences RRT activation processes of care. The RRT role should be an adjunct to, but not a substitute for, an engaged and present primary care team. Copyright © 2014 Elsevier Inc. All rights reserved.

  19. Rapid Application of Space Effects for the Small Satellites Systems and Services Symposium

    Science.gov (United States)

    Tsairides, Demosthenes; Finley, Charles; Moretti, George

    2016-01-01

    NASA Ames Research Center (ARC) has engaged Military Branches, the Department of Defense, and other Government Agencies in successful partnerships to design, develop, deliver and support various space effects capabilities and space vehicles on timeline of need. Contracts with Industry are in place to execute operational and enabler missions using physical and informational infrastructures including Responsive Manufacturing capabilities and Digital Assurance. The intent is to establish a secure, web-enabled "store front" for ordering and delivering any capabilities required as defined by the users and directed by NASA ARC and Partner Organizations. The capabilities are envisioned to cover a broad range and include 6U CubeSats, 50-100 kg Space Vehicles, Modular Space Vehicle architecture variations, as well as rapid payload integration on various Bus options. The paper will discuss the efforts underway to demonstrate autonomous manufacturing of low-volume, high-value assets, to validate the ability of autonomous digital techniques to provide Mission Assurance, and to demonstrate cost savings through the identification, characterization, and utilization of Responsive Space components. The culmination of this effort will be the integration of several 6U satellites and their launch in 2016.

  20. Chitin nanofibrils for rapid and efficient removal of metal ions from water system.

    Science.gov (United States)

    Liu, Dagang; Zhu, Yi; Li, Zehui; Tian, Donglin; Chen, Lei; Chen, Peng

    2013-10-15

    Joint mechanical defibrillation was successfully used to downsize chitin micro-particles (CMP) into nanofibrils without changing its chemical or crystalline structure. The fine chitin nanofibrils (CNF) bearing width of about 50 nm and length of more than 1 μm were then developed as heavy metal ion sorbents. The uptake performance of CNF dependent on pH, ionic concentration, time, and temperature was investigated. Results show that fixation amount of Cd(II), Ni(II), Cu(II), Zn(II), Pb(II), Cr(III) on CNF was up to 2.94, 2.30, 2.22, 2.06, 1.46, and 0.31 mmol/g, respectively, much higher than CMP due to high specific surface area and widely distributed pores of CNF. Adsorption kinetics of CMP and CNF followed pseudo-second-order model and Freundlich isotherm although CNF exhibited higher rate constant and sorption capacity than that of CMP. The defibrillated CNF is renewable, feasible, easily recyclable, and is thought as good candidate for heavy metal ion treatment due to their low sorption energy, rapid and efficient uptake capacity. Copyright © 2013 Elsevier Ltd. All rights reserved.

  1. Simulation and Rapid Prototyping of Adaptive Control Systems using the Adaptive Blockset for Simulink

    DEFF Research Database (Denmark)

    Ravn, Ole

    1998-01-01

    The paper describes the design considerations and implementational aspects of the Adaptive Blockset for Simulink which has been developed in a prototype implementation. The concept behind the Adaptive Blockset for Simulink is to bridge the gap between simulation and prototype controller implement...... design, controller and state variable filter.The use of the Adaptive Blockset is demonstrated using a simple laboratory setup. Both the use of the blockset for simulation and for rapid prototyping of a real-time controller are shown.......The paper describes the design considerations and implementational aspects of the Adaptive Blockset for Simulink which has been developed in a prototype implementation. The concept behind the Adaptive Blockset for Simulink is to bridge the gap between simulation and prototype controller...... implementation. This is done using the code generation capabilities of Real Time Workshop in combination with C s-function blocks for adaptive control in Simulink. In the paper the design of each group of blocks normally found in adaptive controllers is outlined. The block types are, identification, controller...

  2. Rapid Assessment of the Ce-Co-Fe-Cu System for Permanent Magnetic Applications

    Science.gov (United States)

    Meng, F.; Chaudhary, R. P.; Gandha, K.; Nlebedim, I. C.; Palasyuk, A.; Simsek, E.; Kramer, M. J.; Ott, R. T.

    2018-06-01

    This work focuses on the rapid synthesis and characterization of quaternary Ce(CoFeCu)5 alloy libraries to assess their potential viability as permanent magnets. Arrays of bulk specimens with controlled compositions were synthesized via laser engineered net shaping (LENS) by feeding different ratios of alloy powders into a melt pool created by a laser. Based on the assessment of the magnetic properties of the LENS printed samples, arc-melted and cast ingots were prepared with varying Fe (5-20 at.%) and Co (60-45 at.%) compositions while maintaining constant Ce (16 at.%) and Cu (19 at.%) content. The evolution of the microstructure and phases with varying chemical compositions and their dependence on magnetic properties are analyzed in as-cast and heat-treated samples. In both the LENS printed and cast samples, we find the best magnetic properties correspond to a predominantly single-phase Ce(CoFeCu)5 microstructure in which high coercivity ( H c > 10 kOe) can be achieved without any microstructural refinement.

  3. Comparison of Enzymatic Method Rapid Yeast Plus System with RFLP-PCR for Identification of Isolated Yeast from Vulvovaginal Candidiasis.

    Science.gov (United States)

    Hossein, Moallaei; Mirhendi, Seied Hossein; Brandão, João; Mirdashti, Reza; Rosado, Laura

    2011-09-01

    To compare two identification methods, i.e., restriction fragment length polymorphism (RFLP)-PCR analysis and enzymatic method Rapid TM Yeast Plus System to identify different species causing vulvovaginal candidiasis (VVC). Vaginal discharges of women who had attended the gynecology outpatient clinic of Mobini Hospital in Sabzevar, Iran were collected using cotton swabs and were cultured on Sabouraud dextrose agar. Isolated yeasts were identified by germ-tube testing and Rapid TM Yeast Plus System (Remel USA). For molecular identification, the isolated DNA was amplified with ITS1 and ITS4 universal primers and PCR products digested with the enzyme HpaІІ followed by agarose gel electrophoresis. Epidemiological and clinical features of women with respect to identified species were also evaluated. Out of 231 subjects enrolled, 62 VVC cases were detected. The isolated species were identified as follows: Candida albicans, 24 (38.7%), C. glabrata, 15 (24.2%), C. kefyr, 13 (21.0%) C. krusei, 9 (14.5%), and Saccharomyces cerevisiae, 1 (1.6%) by RFLP-PCR method; whereas findings by Rapid TM Yeast Plus System were C. albicans, 24 (38.7%), C. glabrata, 5 (8%), C. kefyr, 11 (17.7%) C. krusei, 2 (3.2%), S. cerevisiae, 9 (14.5%), and C. tropicalis, 6 (9.6%) as well as other nonpathogenic yeasts, 4 (6.9%). Statistical comparison showed that there is no significant difference in identification of C. albicans by the two methods; although, in this study, it was not true about other species of yeasts. A correlation between clinical and laboratory findings is important as it enables us to administer an appropriate treatment on time.

  4. Variable Speed (DFIG) Wind Turbines: Rapid Frequency Response to Power System Disturbances

    DEFF Research Database (Denmark)

    Chandrashekhara, Divya K; Hansen, Anca Daniela; Sørensen, Poul Ejnar

    2009-01-01

    This paper examines the effect of integrating large number of wind turbines particularly the double fed induction generator (DFIG) on the virtual inertia of the Danish power system network. The virtual inertia refers to the kinetic energy stored in the rotating masses which can be released...... initially to counter act the frequency change during a power system disturbance. Simulation studies have been carried out on a generic reduced model of a transmission power grid of the Danish TSO Energinet.dk to assess the impact of loss of generation on system frequency. Further, simulation study has been...

  5. The Performance Assessment of the Detector for the Portable Environmental Radiation Distribution Monitoring System with Rapid Nuclide Recognition

    International Nuclear Information System (INIS)

    Lee, Uk Jae; Kim, Hee Reyoung

    2015-01-01

    The environment radiation distribution monitoring system measures the radiation using a portable detector and display the overall radiation distribution. Bluetooth and RS-232 communications are used for constructing monitoring system. However RS-232 serial communication is known to be more stable than Bluetooth and also it can use the detector's raw data which will be used for getting the activity of each artificial nuclide. In the present study, the detection and communication performance of the developed detector with RS-232 method is assessed by using standard sources for the real application to the urban or rural environment. Assessment of the detector for the portable environmental radiation distribution monitoring system with rapid nuclide recognition was carried out. It was understood that the raw data of detector could be effectively treated by using RS-232 method and the measurement showed a good agreement with the calculation within the relative error of 0.4 % in maximum

  6. The Performance Assessment of the Detector for the Portable Environmental Radiation Distribution Monitoring System with Rapid Nuclide Recognition

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Uk Jae; Kim, Hee Reyoung [Ulsan National Institute of Science and Technology, Ulsan (Korea, Republic of)

    2015-05-15

    The environment radiation distribution monitoring system measures the radiation using a portable detector and display the overall radiation distribution. Bluetooth and RS-232 communications are used for constructing monitoring system. However RS-232 serial communication is known to be more stable than Bluetooth and also it can use the detector's raw data which will be used for getting the activity of each artificial nuclide. In the present study, the detection and communication performance of the developed detector with RS-232 method is assessed by using standard sources for the real application to the urban or rural environment. Assessment of the detector for the portable environmental radiation distribution monitoring system with rapid nuclide recognition was carried out. It was understood that the raw data of detector could be effectively treated by using RS-232 method and the measurement showed a good agreement with the calculation within the relative error of 0.4 % in maximum.

  7. Rapid replacement of Tangier Island bridges including lightweight and durable fiber-reinforced polymer deck systems.

    Science.gov (United States)

    2009-01-01

    Fiber-reinforced polymer (FRP) composite cellular deck systems were used as new bridge decks on two replacement bridges on Tangier Island, Virginia. The most important characteristics of this application were reduced self-weight and increased durabil...

  8. DEREChOS: Data Environment for Rapid Exploration and Characterization of Organized Systems

    Data.gov (United States)

    National Aeronautics and Space Administration — Motivation/Problem Statement: DEREChOS is a natural advancement of the existing, highly-successful Automated Event Service (AES) project. AES is an advanced system...

  9. Sensibility Study of St Andrew Bay Rapid Response System for Naval Applications

    National Research Council Canada - National Science Library

    Pauly, Patrice

    2005-01-01

    .... For the physical part, time constraint may limit to using the barotropic mode. But because rain can be significant in St Andrew Bay system, Florida, fresh water, even when rivers lack, is a prevailing salinity regulator through ground seepage...

  10. An Advanced Rapid Cycling CO2 and H2O Control System for PLSS, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — NASA's planned future missions set stringent demands on the design of the Portable Life Support Systems (PLSS) used to cool the astronaut and provide them with air....

  11. An Advanced Rapid Cycling CO2 and H2O Control System for PLSS, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — NASA's planned future missions set stringent demands on the design of the Portable Life Support Systems (PLSS), requiring dramatic reductions in weight, decreased...

  12. Coordinated Control of Multi-Agent Systems in Rapidly Varying Environments, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — In this STTR project Scientific Systems Company, Inc. (SSCI) and Brigham Young University (BYU) propose to design, implement, and test an Autonomous Coordinated...

  13. A versatile system for the rapid collection, handling and graphics analysis of multidimensional data

    International Nuclear Information System (INIS)

    O'Brien, P.M.; Moloney, G.; O'Oconnor, A.; Legge, G.J.F.

    1991-01-01

    The paper discusses the performances of a versatile computerized system developed at the Microanalytical Research Centre of the Melbourne University, for handling multiparameter data that may arise from a variety of experiments - nuclear, accelerator mass spectrometry, microprobe elemental analysis or 3-D microtomography. Some of the most demanding requirements arise in the application of microprobes to quantitative elemental mapping and to microtomography. A system to handle data from such experiments had been under continuous development. It has been reprogramed to run on a DG DS7540 workstation. The whole system of software has been rewritten, greatly expanded and made much more powerful and faster, by use of modern computer technology - a VME bus computer with a real-time operating system and a RISC workstation running UNIX and the X-window environment

  14. Interactive visual steering--rapid visual prototyping of a common rail injection system.

    Science.gov (United States)

    Matković, Kresimir; Gracanin, Denis; Jelović, Mario; Hauser, Helwig

    2008-01-01

    Interactive steering with visualization has been a common goal of the visualization research community for twenty years, but it is rarely ever realized in practice. In this paper we describe a successful realization of a tightly coupled steering loop, integrating new simulation technology and interactive visual analysis in a prototyping environment for automotive industry system design. Due to increasing pressure on car manufacturers to meet new emission regulations, to improve efficiency, and to reduce noise, both simulation and visualization are pushed to their limits. Automotive system components, such as the powertrain system or the injection system have an increasing number of parameters, and new design approaches are required. It is no longer possible to optimize such a system solely based on experience or forward optimization. By coupling interactive visualization with the simulation back-end (computational steering), it is now possible to quickly prototype a new system, starting from a non-optimized initial prototype and the corresponding simulation model. The prototyping continues through the refinement of the simulation model, of the simulation parameters and through trial-and-error attempts to an optimized solution. The ability to early see the first results from a multidimensional simulation space--thousands of simulations are run for a multidimensional variety of input parameters--and to quickly go back into the simulation and request more runs in particular parameter regions of interest significantly improves the prototyping process and provides a deeper understanding of the system behavior. The excellent results which we achieved for the common rail injection system strongly suggest that our approach has a great potential of being generalized to other, similar scenarios.

  15. A rapid calculation system for tsunami propagation in Japan by using the AQUA-MT/CMT solutions

    Science.gov (United States)

    Nakamura, T.; Suzuki, W.; Yamamoto, N.; Kimura, H.; Takahashi, N.

    2017-12-01

    We developed a rapid calculation system of geodetic deformations and tsunami propagation in and around Japan. The system automatically conducts their forward calculations by using point source parameters estimated by the AQUA system (Matsumura et al., 2006), which analyze magnitude, hypocenter, and moment tensors for an event occurring in Japan in 3 minutes of the origin time at the earliest. An optimized calculation code developed by Nakamura and Baba (2016) is employed for the calculations on our computer server with 12 core processors of Intel Xeon 2.60 GHz. Assuming a homogeneous fault slip in the single fault plane as the source fault, the developed system calculates each geodetic deformation and tsunami propagation by numerically solving the 2D linear long-wave equations for the grid interval of 1 arc-min from two fault orientations simultaneously; i.e., one fault and its conjugate fault plane. Because fault models based on moment tensor analyses of event data are used, the system appropriately evaluate tsunami propagation even for unexpected events such as normal faulting in the subduction zone, which differs with the evaluation of tsunami arrivals and heights from a pre-calculated database by using fault models assuming typical types of faulting in anticipated source areas (e.g., Tatehata, 1998; Titov et al., 2005; Yamamoto et al., 2016). By the complete automation from event detection to output graphical figures, the calculation results can be available via e-mail and web site in 4 minutes of the origin time at the earliest. For moderate-sized events such as M5 to 6 events, the system helps us to rapidly investigate whether amplitudes of tsunamis at nearshore and offshore stations exceed a noise level or not, and easily identify actual tsunamis at the stations by comparing with obtained synthetic waveforms. In the case of using source models investigated from GNSS data, such evaluations may be difficult because of the low resolution of sources due to a low

  16. Spatial and Temporal Evolution of Urban Systems in China during Rapid Urbanization

    Directory of Open Access Journals (Sweden)

    Huan Li

    2016-07-01

    Full Text Available The structure of urban hierarchy and the role of cities of different sizes have drawn considerable scholarly interests and societal concerns. This paper analyzes the evolution and underlying mechanisms of urban hierarchy in China during the recent period of rapid urbanization. By comparing scale changes of seven types of cities (megacity, large city, Type I big city, Type II big city, medium-sized city, type I small city and type II small city, we find that allometry is the main characteristic of urban hierarchical evolution in China. We also test the validity of Zipf’s law and Gibrat’s law, which broaden the scope of existing studies by including county-level cities. We find that urban hierarchical distribution is lognormal, rather than Pareto. The result also shows that city size growth rates are constant across cities of different types. For better understanding of the mechanisms of urban hierarchical formation, we measure the optimal city size and resource allocation by the Pareto optimality criterion and non-parametric frontier method. The main findings are as follows: (1 scale efficiency is still at a relatively low level among the seven types of cities; (2 the economic efficiency of megacities and large cities is overestimated when compared to economic-environmental efficiency. Hence, this paper has two policy implications: (1 to correct factor market (land, labor and infrastructure investment distortions among different types of cities for the improvement of efficiency; (2 to strengthen rural property rights to improve social equity, as well as land use intensity.

  17. Control System of 3 GeV Rapid Cycling Synchrotron at J-PARC

    CERN Document Server

    Takahashi, Hiroki; Kato, Yuko; Kawase, Masato; Sakaki, Hironao; Sako, Hiroyuki; Sugimoto, Makoto; Yoshikawa, Hiroshi

    2005-01-01

    Since the 3GeV RCS produces huge beam power of 1 MW, extreme cares must be taken to design the control system in order to minimize radiation due to beam loss. Another complexity appears in the control system, because each beam bunch of 25 Hz is required to be injected either into the MLF* or into the 50GeV MR.** Therefore, each bunch of 25 Hz must be operated separately, and the data acquisition system must collect synchronized data within each pulse. To achieve these goals, a control system via reflective memory and wave endless recorders has been developed. EPICS is adopted in the control system. Since the number of devices is huge, the management of EPICS records and their configurations require huge amount of time and man power. To reduce this work significantly, a RDB*** for static machine information has been developed. This RDB stores (1) EPICS related information of devices, interfaces, and IOC's**** with a capability to generate EPICS records automatically, and (2) machine geometrical information wit...

  18. Rapid generation of control parameters of Multi-Infeed system through online simulation

    Directory of Open Access Journals (Sweden)

    Rasool Aazim

    2017-05-01

    Full Text Available Simulated Self-Generated - Particle Swarm optimization (SSG-PSO toolbox that automatically generates PI control parameters very quickly in PSCAD is designed. This toolbox operates by utilizing transient simulation to evaluate objective function and converges the fitness values of objective function through PSO algorithm during run time simulation of Multi-infeed HVDC systems. Integral Square Error-Objective Function (ISE-OF is used to accomplish the task. To make the toolbox faster, ranges are set for PSO generated value that limit the time of data acquisition for the objective function by only considering transition time of a system. This toolbox has a capability to optimize multiple controllers at same time. The PI values are generated faster and the results are showing markedly improved performance of a system during startup and under fault condition. The experimental results are presented in this paper.

  19. Effects of new bus and rail rapid transit systems – an international review

    DEFF Research Database (Denmark)

    Ingvardson, Jesper Bláfoss; Nielsen, Otto Anker

    2018-01-01

    areas surrounding the transit line with increasing property values. Such effects are traditionally associated with attractive rail-based public transport systems. However, a statistical comparison of 41 systems did not show significant deviations between effects on property values resulting from BRT...... time, ridership and modal shifts, and (ii) the indirect strategic effects in terms of effects on property values and urban development. The review confirms the existing literature suggesting that BRT can attract many passengers if travel time reductions are significantly high. This leads to attractive...

  20. Rapidly Deployable Security System Final Report CRADA No. TC-2030-01

    Energy Technology Data Exchange (ETDEWEB)

    Kohlhepp, V. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Whiteman, B. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); McKibben, M. T. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2017-09-28

    The ultimate objective of the LEADER and LLNL strategic partnership was to develop and commercialize_a security-based system product and platform for the use in protecting the substantial physical and economic assets of the government and commerce of the United States. The primary goal of this project was to integrate video surveillance hardware developed by LLNL with a security software backbone developed by LEADER. Upon completion of the project, a prototype hardware/software security system that is highly scalable was to be demonstrated.

  1. The Rapid Disaster Evaluation System (RaDES): A Plan to Improve Global Disaster Response by Privatizing the Assessment Component.

    Science.gov (United States)

    Iserson, Kenneth V

    2017-09-01

    Emergency medicine personnel frequently respond to major disasters. They expect to have an effective and efficient management system to elegantly allocate available resources. Despite claims to the contrary, experience demonstrates this rarely occurs. This article describes privatizing disaster assessment using a single-purposed, accountable, and well-trained organization. The goal is to achieve elegant disaster assessment, rather than repeatedly exhorting existing groups to do it. The Rapid Disaster Evaluation System (RaDES) would quickly and efficiently assess a postdisaster population's needs. It would use an accountable nongovernmental agency's teams with maximal training, mobility, and flexibility. Designed to augment the Inter-Agency Standing Committee's 2015 Emergency Response Preparedness Plan, RaDES would provide the initial information needed to avoid haphazard and overlapping disaster responses. Rapidly deployed teams would gather information from multiple sources and continually communicate those findings to their base, which would then disseminate them to disaster coordinators in a concise, coherent, and transparent way. The RaDES concept represents an elegant, minimally bureaucratic, and effective rapid response to major disasters. However, its implementation faces logistical, funding, and political obstacles. Developing and maintaining RaDES would require significant funding and political commitment to coordinate the numerous agencies that claim to be performing the same tasks. Although simulations can demonstrate efficacy and deficiencies, only field tests will demonstrate RaDES' power to improve interagency coordination and decrease the cost of major disaster response. At the least, the RaDES concept should serve as a model for discussing how to practicably improve our current chaotic disaster responses. Copyright © 2016 Elsevier Inc. All rights reserved.

  2. A multiplexed microfluidic toolbox for the rapid optimization of affinity-driven partition in aqueous two phase systems.

    Science.gov (United States)

    Bras, Eduardo J S; Soares, Ruben R G; Azevedo, Ana M; Fernandes, Pedro; Arévalo-Rodríguez, Miguel; Chu, Virginia; Conde, João P; Aires-Barros, M Raquel

    2017-09-15

    Antibodies and other protein products such as interferons and cytokines are biopharmaceuticals of critical importance which, in order to be safely administered, have to be thoroughly purified in a cost effective and efficient manner. The use of aqueous two-phase extraction (ATPE) is a viable option for this purification, but these systems are difficult to model and optimization procedures require lengthy and expensive screening processes. Here, a methodology for the rapid screening of antibody extraction conditions using a microfluidic channel-based toolbox is presented. A first microfluidic structure allows a simple negative-pressure driven rapid screening of up to 8 extraction conditions simultaneously, using less than 20μL of each phase-forming solution per experiment, while a second microfluidic structure allows the integration of multi-step extraction protocols based on the results obtained with the first device. In this paper, this microfluidic toolbox was used to demonstrate the potential of LYTAG fusion proteins used as affinity tags to optimize the partitioning of antibodies in ATPE processes, where a maximum partition coefficient (K) of 9.2 in a PEG 3350/phosphate system was obtained for the antibody extraction in the presence of the LYTAG-Z dual ligand. This represents an increase of approx. 3.7 fold when compared with the same conditions without the affinity molecule (K=2.5). Overall, this miniaturized and versatile approach allowed the rapid optimization of molecule partition followed by a proof-of-concept demonstration of an integrated back extraction procedure, both of which are critical procedures towards obtaining high purity biopharmaceuticals using ATPE. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Rapid High-Level Production of Functional HIV Broadly Neutralizing Monoclonal Antibodies in Transient Plant Expression Systems

    Science.gov (United States)

    Rosenberg, Yvonne; Sack, Markus; Montefiori, David; Forthal, Donald; Mao, Lingjun; -Abanto, Segundo Hernandez; Urban, Lori; Landucci, Gary; Fischer, Rainer; Jiang, Xiaoming

    2013-01-01

    Passive immunotherapy using anti-HIV broadly neutralizing monoclonal antibodies (mAbs) has shown promise as an HIV treatment, reducing mother-to-child-transmission (MTCT) of simian/human immunodeficiency virus (SHIV) in non-human primates and decreasing viral rebound in patients who ceased receiving anti-viral drugs. In addition, a cocktail of potent mAbs may be useful as mucosal microbicides and provide an effective therapy for post-exposure prophylaxis. However, even highly neutralizing HIV mAbs used today may lose their effectiveness if resistance occurs, requiring the rapid production of new or engineered mAbs on an ongoing basis in order to counteract the viral resistance or the spread of a certain HIV-1 clade in a particular region or patient. Plant-based expression systems are fast, inexpensive and scalable and are becoming increasingly popular for the production of proteins and monoclonal antibodies. In the present study, Agrobacterium-mediated transient transfection of plants, utilizing two species of Nicotiana, have been tested to rapidly produce high levels of an HIV 89.6PΔ140env and several well-studied anti-HIV neutralizing monoclonal antibodies (b12, 2G12, 2F5, 4E10, m43, VRC01) or a single chain antibody construct (m9), for evaluation in cell-based viral inhibition assays. The protein-A purified plant-derived antibodies were intact, efficiently bound HIV envelope, and were equivalent to, or in one case better than, their counterparts produced in mammalian CHO or HEK-293 cells in both neutralization and antibody dependent viral inhibition assays. These data indicate that transient plant-based transient expression systems are very adaptable and could rapidly generate high levels of newly identified functional recombinant HIV neutralizing antibodies when required. In addition, they warrant detailed cost-benefit analysis of prolonged incubation in plants to further increase mAb production. PMID:23533588

  4. Rapid high-level production of functional HIV broadly neutralizing monoclonal antibodies in transient plant expression systems.

    Directory of Open Access Journals (Sweden)

    Yvonne Rosenberg

    Full Text Available Passive immunotherapy using anti-HIV broadly neutralizing monoclonal antibodies (mAbs has shown promise as an HIV treatment, reducing mother-to-child-transmission (MTCT of simian/human immunodeficiency virus (SHIV in non-human primates and decreasing viral rebound in patients who ceased receiving anti-viral drugs. In addition, a cocktail of potent mAbs may be useful as mucosal microbicides and provide an effective therapy for post-exposure prophylaxis. However, even highly neutralizing HIV mAbs used today may lose their effectiveness if resistance occurs, requiring the rapid production of new or engineered mAbs on an ongoing basis in order to counteract the viral resistance or the spread of a certain HIV-1 clade in a particular region or patient. Plant-based expression systems are fast, inexpensive and scalable and are becoming increasingly popular for the production of proteins and monoclonal antibodies. In the present study, Agrobacterium-mediated transient transfection of plants, utilizing two species of Nicotiana, have been tested to rapidly produce high levels of an HIV 89.6PΔ140env and several well-studied anti-HIV neutralizing monoclonal antibodies (b12, 2G12, 2F5, 4E10, m43, VRC01 or a single chain antibody construct (m9, for evaluation in cell-based viral inhibition assays. The protein-A purified plant-derived antibodies were intact, efficiently bound HIV envelope, and were equivalent to, or in one case better than, their counterparts produced in mammalian CHO or HEK-293 cells in both neutralization and antibody dependent viral inhibition assays. These data indicate that transient plant-based transient expression systems are very adaptable and could rapidly generate high levels of newly identified functional recombinant HIV neutralizing antibodies when required. In addition, they warrant detailed cost-benefit analysis of prolonged incubation in plants to further increase mAb production.

  5. Development of a high efficiency integration system and promoter library for rapid modification of Pseudomonas putida KT2440

    Energy Technology Data Exchange (ETDEWEB)

    Elmore, Joshua R. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States). Biosciences Division; Furches, Anna [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States). Biosciences Division; Wolff, Gara N. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States). Biosciences Division; Gorday, Kent [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States). Biosciences Division; Guss, Adam M. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States). Biosciences Division

    2017-04-15

    Pseudomonas putida strains are highly robust bacteria known for their ability to efficiently utilize a variety of carbon sources, including aliphatic and aromatic hydrocarbons. Recently, P. putida has been engineered to valorize the lignin stream of a lignocellulosic biomass pretreatment process. Nonetheless, when compared to platform organisms such as Escherichia coli, the toolkit for engineering P. putida is underdeveloped. Heterologous gene expression in particular is problematic. Plasmid instability and copy number variance provide challenges for replicative plasmids, while use of homologous recombination for insertion of DNA into the chromosome is slow and laborious. Furthermore, heterologous expression efforts to date typically rely on overexpression of exogenous pathways using a handful of poorly characterized promoters. In order to improve the P. putida toolkit, we developed a rapid genome integration system using the site-specific recombinase from bacteriophage Bxb1 to enable rapid, high efficiency integration of DNA into the P. putida chromosome. We also developed a library of synthetic promoters with various UP elements, -35 sequences, and -10 sequences, as well as different ribosomal binding sites. We tested these promoters using a fluorescent reporter gene, mNeonGreen, to characterize the strength of each promoter, and identified UP-element-promoter-ribosomal binding sites combinations capable of driving a ~150-fold range of protein expression levels. One additional integrating vector was developed that confers more robust kanamycin resistance when integrated at single copy into the chromosome. This genome integration and reporter systems are extensible for testing other genetic parts, such as examining terminator strength, and will allow rapid integration of heterologous pathways for metabolic engineering.

  6. The membrane attack complex of the complement system is essential for rapid wallerian degeneration

    NARCIS (Netherlands)

    Ramaglia, Valeria; King, Rosalind Helen Mary; Nourallah, Michelle; Wolterman, Ruud; de Jonge, Rosalein; Ramkema, Marja; Vigar, Miriam Ann; van der Wetering, Sandra; Morgan, Brian Paul; Troost, Dirk; Baas, Frank

    2007-01-01

    The complement (C) system plays an important role in myelin breakdown during Wallerian degeneration (WD). The pathway and mechanism involved are, however, not clear. In a crush injury model of the sciatic nerve, we show that C6, necessary for the assembly of the membrane attack complex (MAC), is

  7. A multistep continuous-flow system for rapid on-demand synthesis of receptor ligands

    DEFF Research Database (Denmark)

    Petersen, Trine P; Ritzén, Andreas; Ulven, Trond

    2009-01-01

    A multistep continuous-flow system for synthesis of receptor ligands by assembly of three variable building blocks in a single unbroken flow is described. The sequence consists of three reactions and two scavenger steps, where a Cbz-protected diamine is reacted with an isocyanate, deprotected, an......, and reacted further with an alkylating agent....

  8. Biometric Fingerprint System to Enable Rapid and Accurate Identification of Beneficiaries

    OpenAIRE

    Storisteanu, Daniel Matthew L; Norman, Toby L; Grigore, Alexandra; Norman, Tristram L

    2015-01-01

    Inability to uniquely identify clients impedes access to services and contributes to inefficiencies. Using a pocket-sized fingerprint scanner that wirelessly syncs with a health worker's smartphone, the SimPrints biometric system can link individuals' fingerprints to their health records. A pilot in Bangladesh will assess its potential.

  9. A selectable and excisable marker system for the rapid creation of recombinant poxviruses.

    Directory of Open Access Journals (Sweden)

    Julia L Rintoul

    Full Text Available Genetic manipulation of poxvirus genomes through attenuation, or insertion of therapeutic genes has led to a number of vector candidates for the treatment of a variety of human diseases. The development of recombinant poxviruses often involves the genomic insertion of a selectable marker for purification and selection purposes. The use of marker genes however inevitably results in a vector that contains unwanted genetic information of no therapeutic value.Here we describe an improved strategy that allows for the creation of marker-free recombinant poxviruses of any species. The Selectable and Excisable Marker (SEM system incorporates a unique fusion marker gene for the efficient selection of poxvirus recombinants and the Cre/loxP system to facilitate the subsequent removal of the marker. We have defined and characterized this new methodological tool by insertion of a foreign gene into vaccinia virus, with the subsequent removal of the selectable marker. We then analyzed the importance of loxP orientation during Cre recombination, and show that the SEM system can be used to introduce site-specific deletions or inversions into the viral genome. Finally, we demonstrate that the SEM strategy is amenable to other poxviruses, as demonstrated here with the creation of an ectromelia virus recombinant lacking the EVM002 gene.The system described here thus provides a faster, simpler and more efficient means to create clinic-ready recombinant poxviruses for therapeutic gene therapy applications.

  10. Shooting the Rapids: Navigating Transitions to Adaptive Governance of Social-Ecological Systems

    Directory of Open Access Journals (Sweden)

    Per Olsson

    2006-06-01

    Full Text Available The case studies of Kristianstads Vattenrike, Sweden; the Northern Highlands Lake District and the Everglades in the USA; the Mae Nam Ping Basin, Thailand; and the Goulburn-Broken Catchment, Australia, were compared to assess the outcome of different actions for transforming social-ecological systems (SESs. The transformations consisted of two phases, a preparation phase and a transition phase, linked by a window of opportunity. Key leaders and shadow networks can prepare a system for change by exploring alternative system configurations and developing strategies for choosing from among possible futures. Key leaders can recognize and use or create windows of opportunity and navigate transitions toward adaptive governance. Leadership functions include the ability to span scales of governance, orchestrate networks, integrate and communicate understanding, and reconcile different problem domains. Successful transformations rely on epistemic and shadow networks to provide novel ideas and ways of governing SESs. We conclude by listing some ð"„¬rules of thumb" that can help build leadership and networks for successful transformations toward adaptive governance of social-ecological systems.

  11. A Mobile Acoustic Subsurface Sensing (MASS) system for rapid roadway assessment.

    Science.gov (United States)

    Lu, Yifeng; Zhang, Yi; Cao, Yinghong; McDaniel, J Gregory; Wang, Ming L

    2013-05-08

    Surface waves are commonly used for vibration-based nondestructive testing for infrastructure. Spectral Analysis of Surface Waves (SASW) has been used to detect subsurface properties for geologic inspections. Recently, efforts were made to scale down these subsurface detection approaches to see how they perform on small-scale structures such as concrete slabs and pavements. Additional efforts have been made to replace the traditional surface-mounted transducers with non-contact acoustic transducers. Though some success has been achieved, most of these new approaches are inefficient because they require point-to-point measurements or off-line signal analysis. This article introduces a Mobile Acoustic Subsurface Sensing system as MASS, which is an improved surface wave based implementation for measuring the subsurface profile of roadways. The compact MASS system is a 3-wheeled cart outfitted with an electromagnetic impact source, distance register, non-contact acoustic sensors and data acquisition/ processing equipment. The key advantage of the MASS system is the capability to collect measurements continuously at walking speed in an automatic way. The fast scan and real-time analysis advantages are based upon the non-contact acoustic sensing and fast air-coupled surface wave analysis program. This integration of hardware and software makes the MASS system an efficient mobile prototype for the field test.

  12. Macrophyte Community Response to Nitrogen Loading and Thermal Stressors in Rapidly Flushed Mesocosm Systems

    Science.gov (United States)

    Increased nitrogen loading has been directly linked to the proliferation of planktonic and macroalgal blooms at a global scale with negative impacts on estuarine ecology and human health. Under excessive anthropogenic nutrient loads, seagrass systems can be replaced by either ma...

  13. A Mobile Acoustic Subsurface Sensing (MASS System for Rapid Roadway Assessment

    Directory of Open Access Journals (Sweden)

    Ming L. Wang

    2013-05-01

    Full Text Available Surface waves are commonly used for vibration-based nondestructive testing for infrastructure. Spectral Analysis of Surface Waves (SASW has been used to detect subsurface properties for geologic inspections. Recently, efforts were made to scale down these subsurface detection approaches to see how they perform on small-scale structures such as concrete slabs and pavements. Additional efforts have been made to replace the traditional surface-mounted transducers with non-contact acoustic transducers. Though some success has been achieved, most of these new approaches are inefficient because they require point-to-point measurements or off-line signal analysis. This article introduces a Mobile Acoustic Subsurface Sensing system as MASS, which is an improved surface wave based implementation for measuring the subsurface profile of roadways. The compact MASS system is a 3-wheeled cart outfitted with an electromagnetic impact source, distance register, non-contact acoustic sensors and data acquisition/ processing equipment. The key advantage of the MASS system is the capability to collect measurements continuously at walking speed in an automatic way. The fast scan and real-time analysis advantages are based upon the non-contact acoustic sensing and fast air-coupled surface wave analysis program. This integration of hardware and software makes the MASS system an efficient mobile prototype for the field test.

  14. An Embedded Systems Laboratory to Support Rapid Prototyping of Robotics and the Internet of Things

    Science.gov (United States)

    Hamblen, J. O.; van Bekkum, G. M. E.

    2013-01-01

    This paper describes a new approach for a course and laboratory designed to allow students to develop low-cost prototypes of robotic and other embedded devices that feature Internet connectivity, I/O, networking, a real-time operating system (RTOS), and object-oriented C/C++. The application programming interface (API) libraries provided permit…

  15. Rapid prototyping of nanofluidic systems using size-reduced electrospun nanofibers for biomolecular analysis.

    Science.gov (United States)

    Park, Seung-Min; Huh, Yun Suk; Szeto, Kylan; Joe, Daniel J; Kameoka, Jun; Coates, Geoffrey W; Edel, Joshua B; Erickson, David; Craighead, Harold G

    2010-11-05

    Biomolecular transport in nanofluidic confinement offers various means to investigate the behavior of biomolecules in their native aqueous environments, and to develop tools for diverse single-molecule manipulations. Recently, a number of simple nanofluidic fabrication techniques has been demonstrated that utilize electrospun nanofibers as a backbone structure. These techniques are limited by the arbitrary dimension of the resulting nanochannels due to the random nature of electrospinning. Here, a new method for fabricating nanofluidic systems from size-reduced electrospun nanofibers is reported and demonstrated. As it is demonstrated, this method uses the scanned electrospinning technique for generation of oriented sacrificial nanofibers and exposes these nanofibers to harsh, but isotropic etching/heating environments to reduce their cross-sectional dimension. The creation of various nanofluidic systems as small as 20 nm is demonstrated, and practical examples of single biomolecular handling, such as DNA elongation in nanochannels and fluorescence correlation spectroscopic analysis of biomolecules passing through nanochannels, are provided.

  16. Rapid Prototyping for Heterogeneous Multicomponent Systems: An MPEG-4 Stream over a UMTS Communication Link

    Directory of Open Access Journals (Sweden)

    Sorel Y

    2006-01-01

    Full Text Available Future generations of mobile phones, including advanced video and digital communication layers, represent a great challenge in terms of real-time embedded systems. Programmable multicomponent architectures can provide suitable target solutions combining flexibility and computation power. The aim of our work is to develop a fast and automatic prototyping methodology dedicated to signal processing application implementation on parallel heterogeneous architectures, two major features required by future systems. This paper presents the whole methodology based on the SynDEx CAD tool that directly generates a distributed implementation onto various platforms from a high-level application description, taking real-time aspects into account. It illustrates the methodology in the context of real-time distributed executives for multilayer applications based on an MPEG-4 video codec and a UMTS telecommunication link.

  17. Pulse pile-up in nuclear particle detection systems with rapidly varying counting rates

    International Nuclear Information System (INIS)

    Datlowe, D.W.

    1977-01-01

    Pulse pile-up in nuclear particle detection systems is the distortion of the measured pulse height distribution which occurs when there is a significant probability that more than one particle will arrive within the detector resolving time. This paper treats the problem in cases where the probability of pile-up varies on a time scale comparable to the rise time of the detector system electronics. These variations introduce structure into the pulse height distributions which cannot occur for a time-independent pile-up probability. Three classes of problems which exemplify these effects are as follows: 1) Pile-up rejection circuits. 2) Cascaded nuclear decays, in which the lifetime for emission of a second X-ray is comparable to the detector rise time. 3) Bursts of particles where the intensity is modulated on a time scale comparable to the detector rise time. These problems are solved computationally by an extension of a numerical technique previously developed. (Auth.)

  18. Simulation scenarios for rapid reduction in carbon dioxide emissions in the western electricity system

    International Nuclear Information System (INIS)

    Ford, Andrew

    2008-01-01

    This paper describes a computer simulation analysis of carbon dioxide emissions in the electric power system in the western United States. Legislation at both the state and federal level would impose a price on emissions via cap-and-trade in allowances for carbon dioxide emissions. The simulation scenarios for the western system indicate that dramatic reductions in emissions are possible with generating technologies that exist today. Wind and biomass generators play a key role even with conservative assumptions about their future costs. In contrast, generation from advanced technologies provide only a minor contribution by the year 2025. These scenarios provide support to those who argue that the US should move expeditiously to put a price on carbon dixoide emissions

  19. Rapid customization system for 3D-printed splint using programmable modeling technique - a practical approach.

    Science.gov (United States)

    Li, Jianyou; Tanaka, Hiroya

    2018-01-01

    Traditional splinting processes are skill dependent and irreversible, and patient satisfaction levels during rehabilitation are invariably lowered by the heavy structure and poor ventilation of splints. To overcome this drawback, use of the 3D-printing technology has been proposed in recent years, and there has been an increase in public awareness. However, application of 3D-printing technologies is limited by the low CAD proficiency of clinicians as well as unforeseen scan flaws within anatomic models.A programmable modeling tool has been employed to develop a semi-automatic design system for generating a printable splint model. The modeling process was divided into five stages, and detailed steps involved in construction of the proposed system as well as automatic thickness calculation, the lattice structure, and assembly method have been thoroughly described. The proposed approach allows clinicians to verify the state of the splint model at every stage, thereby facilitating adjustment of input content and/or other parameters to help solve possible modeling issues. A finite element analysis simulation was performed to evaluate the structural strength of generated models. A fit investigation was applied on fabricated splints and volunteers to assess the wearing experience. Manual modeling steps involved in complex splint designs have been programed into the proposed automatic system. Clinicians define the splinting region by drawing two curves, thereby obtaining the final model within minutes. The proposed system is capable of automatically patching up minor flaws within the limb model as well as calculating the thickness and lattice density of various splints. Large splints could be divided into three parts for simultaneous multiple printing. This study highlights the advantages, limitations, and possible strategies concerning application of programmable modeling tools in clinical processes, thereby aiding clinicians with lower CAD proficiencies to become adept

  20. Rapid data acquisition from the safety system of the FRJ-2 reactor

    International Nuclear Information System (INIS)

    Inhoven, H.

    1980-06-01

    The central department for research reactors (ZFR) of the Juelich Nuclear Research Centre (KFA) is operating the reactors FRJ-1 (MERLIN) and FRJ-2 (DIDO) since 1962. In 1976, a Siemens 330 computer has been put into operation especially for the processing of data from the DIDO reactor, followed by another computer of the same type for the purpose of processing data from the ZFR department in general. The present report is a result of the work investigating 'Data acquisition and data processing in the FRJ-2' and primarily discusses the complex of 'fast analog and binary signals'. The activities in this field of work have been and still are mainly concerned with general problems encountered in adapting a currently 14-year-old reactor system to a digital computer, namely problems such as data decoupling in the safety system of the reactor, data acquisition using the CAMAC system, data transfer via an 'extended branch', data acquisition software as core-resident programs, temporary storage as common data, interpreting software as peripheral - storage - resident programs. (orig./WB) [de

  1. ULtiMATE system for rapid assembly of customized TAL effectors.

    Directory of Open Access Journals (Sweden)

    Junjiao Yang

    Full Text Available Engineered TAL-effector nucleases (TALENs and TALE-based constructs have become powerful tools for eukaryotic genome editing. Although many methods have been reported, it remains a challenge for the assembly of designer-based TALE repeats in a fast, precise and cost-effective manner. We present an ULtiMATE (USER-based Ligation Mediated Assembly of TAL Effector system for speedy and accurate assembly of customized TALE constructs. This method takes advantage of uracil-specific excision reagent (USER to create multiple distinct sticky ends between any neighboring DNA fragments for specific ligation. With pre-assembled templates, multiple TALE DNA-binding domains could be efficiently assembled in order within hours with minimal manual operation. This system has been demonstrated to produce both functional TALENs for effective gene knockout and TALE-mediated gene-specific transcription activation (TALE-TA. The feature of both ease-of-operation and high efficiency of ULtiMATE system makes it not only an ideal method for biologic labs, but also an approach well suited for large-scale assembly of TALENs and any other TALE-based constructions.

  2. BEAP profiles as rapid test system for status analysis and early detection of process incidents in biogas plants.

    Science.gov (United States)

    Refai, Sarah; Berger, Stefanie; Wassmann, Kati; Hecht, Melanie; Dickhaus, Thomas; Deppenmeier, Uwe

    2017-03-01

    A method was developed to quantify the performance of microorganisms involved in different digestion levels in biogas plants. The test system was based on the addition of butyrate (BCON), ethanol (ECON), acetate (ACON) or propionate (PCON) to biogas sludge samples and the subsequent analysis of CH 4 formation in comparison to control samples. The combination of the four values was referred to as BEAP profile. Determination of BEAP profiles enabled rapid testing of a biogas plant's metabolic state within 24 h and an accurate mapping of all degradation levels in a lab-scale experimental setup. Furthermore, it was possible to distinguish between specific BEAP profiles for standard biogas plants and for biogas reactors with process incidents (beginning of NH 4 + -N inhibition, start of acidification, insufficient hydrolysis and potential mycotoxin effects). Finally, BEAP profiles also functioned as a warning system for the early prediction of critical NH 4 + -N concentrations leading to a drop of CH 4 formation.

  3. Experimental shift work studies of permanent night, and rapidly rotating, shift systems. Pt. 1. Behaviour of various characteristics of sleep

    Energy Technology Data Exchange (ETDEWEB)

    Knauth, P.; Rutenfranz, J.; Romberg, H.P.; Decoster, F.; Kiesswetter, E. (Dortmund Univ. (Germany, F.R.). Inst. fuer Arbeitsphysiologie); Schulz, H. (Max-Planck-Institut fuer Psychiatrie, Muenchen (Germany, F.R.). Klinisches Inst.)

    1980-06-01

    In connection with experimental shift work 20 volunteers were examined while working on different rapidly or slowly rotating shift systems. Sleep was analyzed over a total of 112 days. Sleep was disturbed by children's noise or traffic noise. Sleep duration and sleep quality were particularly badly affected by noise with a high information value (children's noise). The ultradian rhythmicity of sleep did not appear to be disrupted by the change from day to night work. There were no significant differences between morning sleep and afternoon sleep after night work. In the laboratory experiments with fixed sleep durations, no separate effects on sleep quality could be established for different shift systems.

  4. Pandemic influenza preparedness and health systems challenges in Asia: results from rapid analyses in 6 Asian countries

    Directory of Open Access Journals (Sweden)

    Putthasri Weerasak

    2010-06-01

    Full Text Available Abstract Background Since 2003, Asia-Pacific, particularly Southeast Asia, has received substantial attention because of the anticipation that it could be the epicentre of the next pandemic. There has been active investment but earlier review of pandemic preparedness plans in the region reveals that the translation of these strategic plans into operational plans is still lacking in some countries particularly those with low resources. The objective of this study is to understand the pandemic preparedness programmes, the health systems context, and challenges and constraints specific to the six Asian countries namely Cambodia, Indonesia, Lao PDR, Taiwan, Thailand, and Viet Nam in the prepandemic phase before the start of H1N1/2009. Methods The study relied on the Systemic Rapid Assessment (SYSRA toolkit, which evaluates priority disease programmes by taking into account the programmes, the general health system, and the wider socio-cultural and political context. The components under review were: external context; stewardship and organisational arrangements; financing, resource generation and allocation; healthcare provision; and information systems. Qualitative and quantitative data were collected in the second half of 2008 based on a review of published data and interviews with key informants, exploring past and current patterns of health programme and pandemic response. Results The study shows that health systems in the six countries varied in regard to the epidemiological context, health care financing, and health service provision patterns. For pandemic preparation, all six countries have developed national governance on pandemic preparedness as well as national pandemic influenza preparedness plans and Avian and Human Influenza (AHI response plans. However, the governance arrangements and the nature of the plans differed. In the five developing countries, the focus was on surveillance and rapid containment of poultry related transmission

  5. A system for rapid prototyping of hearts with congenital malformations based on the medical imaging interaction toolkit (MITK)

    Science.gov (United States)

    Wolf, Ivo; Böttger, Thomas; Rietdorf, Urte; Maleike, Daniel; Greil, Gerald; Sieverding, Ludger; Miller, Stephan; Mottl-Link, Sibylle; Meinzer, Hans-Peter

    2006-03-01

    Precise knowledge of the individual cardiac anatomy is essential for diagnosis and treatment of congenital heart disease. Complex malformations of the heart can best be comprehended not from images but from anatomic specimens. Physical models can be created from data using rapid prototyping techniques, e.g., lasersintering or 3D-printing. We have developed a system for obtaining data that show the relevant cardiac anatomy from high-resolution CT/MR images and are suitable for rapid prototyping. The challenge is to preserve all relevant details unaltered in the produced models. The main anatomical structures of interest are the four heart cavities (atria, ventricles), the valves and the septum separating the cavities, and the great vessels. These can be shown either by reproducing the morphology itself or by producing a model of the blood-pool, thus creating a negative of the morphology. Algorithmically the key issue is segmentation. Practically, possibilities allowing the cardiologist or cardiac surgeon to interactively check and correct the segmentation are even more important due to the complex, irregular anatomy and imaging artefacts. The paper presents the algorithmic and interactive processing steps implemented in the system, which is based on the open-source Medical Imaging Interaction Toolkit (MITK, www.mitk.org). It is shown how the principles used in MITK enable to assemble the system from modules (functionalities) developed independently from each other. The system allows to produce models of the heart (and other anatomic structures) of individual patients as well as to reproduce unique specimens from pathology collections for teaching purposes.

  6. New Clox Systems for rapid and efficient gene disruption in Candida albicans.

    Directory of Open Access Journals (Sweden)

    Shahida Shahana

    Full Text Available Precise genome modification is essential for the molecular dissection of Candida albicans, and is yielding invaluable information about the roles of specific gene functions in this major fungal pathogen of humans. C. albicans is naturally diploid, unable to undergo meiosis, and utilizes a non-canonical genetic code. Hence, specialized tools have had to be developed for gene disruption in C. albicans that permit the deletion of both target alleles, and in some cases, the recycling of the Candida-specific selectable markers. Previously, we developed a tool based on the Cre recombinase, which recycles markers in C. albicans with 90-100% efficiency via site-specific recombination between loxP sites. Ironically, the utility of this system was hampered by the extreme efficiency of Cre, which prevented the construction in Escherichia coli of stable disruption cassettes carrying a methionine-regulatable CaMET3p-cre gene flanked by loxP sites. Therefore, we have significantly enhanced this system by engineering new Clox cassettes that carry a synthetic, intron-containing cre gene. The Clox kit facilitates efficient transformation and marker recycling, thereby simplifying and accelerating the process of gene disruption in C. albicans. Indeed, homozygous mutants can be generated and their markers resolved within two weeks. The Clox kit facilitates strategies involving single marker recycling or multi-marker gene disruption. Furthermore, it includes the dominant NAT1 marker, as well as URA3, HIS1 and ARG4 cassettes, thereby permitting the manipulation of clinical isolates as well as genetically marked strains of C. albicans. The accelerated gene disruption strategies afforded by this new Clox system are likely to have a profound impact on the speed with which C. albicans pathobiology can be dissected.

  7. The kick-in system: a novel rapid knock-in strategy.

    Science.gov (United States)

    Tomonoh, Yuko; Deshimaru, Masanobu; Araki, Kimi; Miyazaki, Yasuhiro; Arasaki, Tomoko; Tanaka, Yasuyoshi; Kitamura, Haruna; Mori, Fumiaki; Wakabayashi, Koichi; Yamashita, Sayaka; Saito, Ryo; Itoh, Masayuki; Uchida, Taku; Yamada, Junko; Migita, Keisuke; Ueno, Shinya; Kitaura, Hiroki; Kakita, Akiyoshi; Lossin, Christoph; Takano, Yukio; Hirose, Shinichi

    2014-01-01

    Knock-in mouse models have contributed tremendously to our understanding of human disorders. However, generation of knock-in animals requires a significant investment of time and effort. We addressed this problem by developing a novel knock-in system that circumvents several traditional challenges by establishing stem cells with acceptor elements enveloping a particular genomic target. Once established, these acceptor embryonic stem (ES) cells are efficient at directionally incorporating mutated target DNA using modified Cre/lox technology. This is advantageous, because knock-ins are not restricted to one a priori selected variation. Rather, it is possible to generate several mutant animal lines harboring desired alterations in the targeted area. Acceptor ES cell generation is the rate-limiting step, lasting approximately 2 months. Subsequent manipulations toward animal production require an additional 8 weeks, but this delimits the full period from conception of the genetic alteration to its animal incorporation. We call this system a "kick-in" to emphasize its unique characteristics of speed and convenience. To demonstrate the functionality of the kick-in methodology, we generated two mouse lines with separate mutant versions of the voltage-dependent potassium channel Kv7.2 (Kcnq2): p.Tyr284Cys (Y284C) and p.Ala306Thr (A306T); both variations have been associated with benign familial neonatal epilepsy. Adult mice homozygous for Y284C, heretofore unexamined in animals, presented with spontaneous seizures, whereas A306T homozygotes died early. Heterozygous mice of both lines showed increased sensitivity to pentylenetetrazole, possibly due to a reduction in M-current in CA1 hippocampal pyramidal neurons. Our observations for the A306T animals match those obtained with traditional knock-in technology, demonstrating that the kick-in system can readily generate mice bearing various mutations, making it a suitable feeder technology toward streamlined phenotyping.

  8. An Open Source Rapid Computer Aided Control System Design Toolchain Using Scilab, Scicos and RTAI Linux

    Science.gov (United States)

    Bouchpan-Lerust-Juéry, L.

    2007-08-01

    Current and next generation on-board computer systems tend to implement real-time embedded control applications (e.g. Attitude and Orbit Control Subsystem (AOCS), Packet Utililization Standard (PUS), spacecraft autonomy . . . ) which must meet high standards of Reliability and Predictability as well as Safety. All these requirements require a considerable amount of effort and cost for Space Sofware Industry. This paper, in a first part, presents a free Open Source integrated solution to develop RTAI applications from analysis, design, simulation and direct implementation using code generation based on Open Source and in its second part summarises this suggested approach, its results and the conclusion for further work.

  9. Investigation of Capabilities and Technologies Supporting Rapid UAV Launch System Development

    Science.gov (United States)

    2015-06-01

    on these aircraft tends to limit their overall aerodynamic efficiency during flight, resulting in lower top speeds and more limited ranges than compa...this problem, a retaining pin was added to the lever-arm that engages a mechanism that is, essentially, a car -door lock [38]. This locking system, which...12.81 DROK 10A/50W 9-32V 12V/24V to 5V Car DC Voltage Con- verter Regulator Power Sup- ply,Waterproof Amazon DROK 10A/50W 9-32V 12V/24V to 5V Car DC

  10. Orientation Assistance for Visually Impaired Passengers within a Bus Rapid Transit System (Transmilenio, using Satellite Geolocation

    Directory of Open Access Journals (Sweden)

    Julián Camargo

    2017-05-01

    Results: 100% of the users were able to reach their destination successfully in the pilot test. In regards to the usability perception, users highlighted features such as sound indications for setting the device and orientation guidance throughout the journey. On the other hand, one of the main difficulties found was to correctly identify the bus approaching the stop and similarly locating the corresponding boarding door, as multiple bus routes may alight in the same door. Conclusions: The device was built incorporating low-cost technologies intended to make it affordable in an eventual mass—scale production. Likewise, a discreet design was chosen so as to lessen the risk of robbery, which unfortunately is a frequent issue in the Transmilenio system due to overcrowding of buses and stations. Additionally, we remark that the prototype can be made smaller by using special—purpose circuit boards. Policy-makers may take into account these considerations for an eventual wide implementation as part of governments’ plans for mobility inclusion in mass-transport systems for disabled people, in comparison with other alternatives such as smart cell phones Language: Spanish.

  11. Laser electro-optic system for rapid three-dimensional /3-D/ topographic mapping of surfaces

    Science.gov (United States)

    Altschuler, M. D.; Altschuler, B. R.; Taboada, J.

    1981-01-01

    It is pointed out that the generic utility of a robot in a factory/assembly environment could be substantially enhanced by providing a vision capability to the robot. A standard videocamera for robot vision provides a two-dimensional image which contains insufficient information for a detailed three-dimensional reconstruction of an object. Approaches which supply the additional information needed for the three-dimensional mapping of objects with complex surface shapes are briefly considered and a description is presented of a laser-based system which can provide three-dimensional vision to a robot. The system consists of a laser beam array generator, an optical image recorder, and software for controlling the required operations. The projection of a laser beam array onto a surface produces a dot pattern image which is viewed from one or more suitable perspectives. Attention is given to the mathematical method employed, the space coding technique, the approaches used for obtaining the transformation parameters, the optics for laser beam array generation, the hardware for beam array coding, and aspects of image acquisition.

  12. [Main principles of rapid diagnosis and intensive care in emergency states: their realization in expert systems].

    Science.gov (United States)

    Zislin, B D; Bazhenov, A M; Belkin, A A; Bazylev, S V; Badaev, F I; Trifonov, Iu O

    1997-01-01

    A retrospective analysis of 543 case histories over 1980-1990 in the town of Yekaterinburg and analysis of published data permitted the authors to single out the signs characterizing the most frequent syndromes requiring urgent intensive care. By either diagnostic value, these signs are distributed into main, accessory, and ruling out. An expert system has been created, making use of the productive-Freimont's approach to representing information on the basis of blurred multiplicities and ambiguous logics. The diagnosis was made by stages: first the main signs were analyzed, determining the severity of patient's status, then (after first aid was rendered) accessory and ruling out signs, which help make the diagnosis more precise. The system was tried in 231 patients, 102 of these with acute respiratory failure, 63 with acute hemodynamic insufficiency, and 66 with acute cerebral insufficiency. Primary diagnosis of the underlying syndrome was correct in 87-89% of cases, of the concomitant syndrome in 92-97%. Repeated evaluations (in 1-3 and 24 h) taking account of the time course of the symptoms and of the results of unsophisticated instrumental examinations increased the share of correct diagnoses to 92-96%.

  13. Liberal Entity Extraction: Rapid Construction of Fine-Grained Entity Typing Systems.

    Science.gov (United States)

    Huang, Lifu; May, Jonathan; Pan, Xiaoman; Ji, Heng; Ren, Xiang; Han, Jiawei; Zhao, Lin; Hendler, James A

    2017-03-01

    The ability of automatically recognizing and typing entities in natural language without prior knowledge (e.g., predefined entity types) is a major challenge in processing such data. Most existing entity typing systems are limited to certain domains, genres, and languages. In this article, we propose a novel unsupervised entity-typing framework by combining symbolic and distributional semantics. We start from learning three types of representations for each entity mention: general semantic representation, specific context representation, and knowledge representation based on knowledge bases. Then we develop a novel joint hierarchical clustering and linking algorithm to type all mentions using these representations. This framework does not rely on any annotated data, predefined typing schema, or handcrafted features; therefore, it can be quickly adapted to a new domain, genre, and/or language. Experiments on genres (news and discussion forum) show comparable performance with state-of-the-art supervised typing systems trained from a large amount of labeled data. Results on various languages (English, Chinese, Japanese, Hausa, and Yoruba) and domains (general and biomedical) demonstrate the portability of our framework.

  14. AAO-CNTs electrode on microfluidic flow injection system for rapid iodide sensing.

    Science.gov (United States)

    Phokharatkul, Ditsayut; Karuwan, Chanpen; Lomas, Tanom; Nacapricha, Duangjai; Wisitsoraat, Anurat; Tuantranont, Adisorn

    2011-06-15

    In this work, carbon nanotubes (CNTs) nanoarrays in anodized aluminum oxide (AAO-CNTs) nanopore is integrated on a microfluidic flow injection system for in-channel electrochemical detection of iodide. The device was fabricated from PDMS (polydimethylsiloxane) microchannel bonded on glass substrates that contains three-electrode electrochemical system, including AAO-CNTs as a working electrode, silver as a reference electrode and platinum as an auxiliary electrode. Aluminum, stainless steel catalyst, silver and platinum layers were sputtered on the glass substrate through shadow masks. Aluminum layer was then anodized by two-step anodization process to form nanopore template. CNTs were then grown in AAO template by thermal chemical vapor deposition. The amperometric detection of iodide was performed in 500-μm-wide and 100-μm-deep microchannels on the microfluidic chip. The influences of flow rate, injection volume and detection potential on the current response were optimized. From experimental results, AAO-CNTs electrode on chip offers higher sensitivity and wider dynamic range than CNTs electrode with no AAO template. Copyright © 2011 Elsevier B.V. All rights reserved.

  15. A system for the rapid detection of bacterial contamination in cell-based therapeutica

    Science.gov (United States)

    Bolwien, Carsten; Erhardt, Christian; Sulz, Gerd; Thielecke, Hagen; Johann, Robert; Pudlas, Marieke; Mertsching, Heike; Koch, Steffen

    2010-02-01

    Monitoring the sterility of cell or tissue cultures is of major concern, particularly in the fields of regenerative medicine and tissue engineering when implanting cells into the human body. Our sterility-control system is based on a Raman micro-spectrometer and is able to perform fast sterility testing on microliters of liquid samples. In conventional sterility control, samples are incubated for weeks to proliferate the contaminants to concentrations above the detection limit of conventional analysis. By contrast, our system filters particles from the liquid sample. The filter chip fabricated in microsystem technology comprises a silicon nitride membrane with millions of sub-micrometer holes to retain particles of critical sizes and is embedded in a microfluidic cell specially suited for concomitant microscopic observation. After filtration, identification is carried out on the single particle level: image processing detects possible contaminants and prepares them for Raman spectroscopic analysis. A custom-built Raman-spectrometer-attachment coupled to the commercial microscope uses 532nm or 785nm Raman excitation and records spectra up to 3400cm-1. In the final step, the recorded spectrum of a single particle is compared to an extensive library of GMP-relevant organisms, and classification is carried out based on a support vector machine.

  16. Bangkok's mass rapid transit system's commuter decision-making process in using integrated smartcards

    Directory of Open Access Journals (Sweden)

    Peerakan Kaewwongwattana

    2016-05-01

    Full Text Available This paper studied the decision-making process to use an integrated smartcard ticketing system by Bangkok metropolitan transit commuters. A second-order Confirmatory Factor Analysis using LISREL 9.10 was undertaken on Bangkok commuter's decision-making process on the use of an integrated smartcard system. The sample consisted of 300 Bangkok commuters obtained by accidental sampling using questionnaires with a 5-point Likert scale. The tools in the research questionnaires used scale estimation that achieved a confidence value of 0.84. The research instruments used rating scales measuring information search, alternative choices, and use decision on the 15 variables in the decision-making process which had factor loadings between 0.49 and 0.89 weight elements when sorted in descending order and overall had a high level. Use decision, alternative choices and information search had a factor of 0.89, 0.65 and 0.49, respectively. There was a good fit of the decision-making model to the empirical data (chi-square = 34.55, probability (p = 0.94, df = 49, RMSEA = 0.00, GFI = 0.98, AGFI = 0.96, SRMR = 0.04.

  17. Evaluation of a rectangular rapid flashing beacon system at the Belmont Ridge Road and W&OD Trail mid-block crosswalk.

    Science.gov (United States)

    2015-05-01

    On April 8, 2013, the Virginia Department of Transportation (VDOT) installed a Rectangular Rapid Flashing Beacon : (RRFB) system at Belmont Ridge Road in Loudoun County that included two units at the Washington and Old Dominion : (W&OD) Trail crossin...

  18. A Portable Cell Maintenance System for Rapid Toxicity Monitoring Final Report CRADA No. TC-02081-04

    Energy Technology Data Exchange (ETDEWEB)

    Kane, S. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Zhou, P. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2017-09-27

    The Phase I STTR research project was targeted at meeting the objectives and requirements stated in STTR solicitation A04-T028 for a Portable Cell Maintenance System for Rapid Toxicity Monitoring. In accordance with the requirements for STTR programs, collaboration was formed between a small business, Kionix, Inc., and The Regents of the University of California, Lawrence Livermore National Laboratory (LLNL). The collaboration included CytoDiscovery, Inc. (CDI) which, in collaboration with Kionix, provided access to membrane chip technology and provided program support and coordination. The objective of the overall program (excerpted from the original solicitation) was: “To develop a small, portable cell maintenance system for the transport, storage, and monitoring of viable vertebrate cells and tissues.” The goal of the Phase I project was to demonstrate the feasibility of achieving the program objectives utilizing a system comprised of a small-size, microfluidic chip-based cell maintenance cartridge (CMC) and a portable cell maintenance system (CMS) capable of housing a minimum of four CMCs. The system was designed to be capable of optimally maintaining multiple vertebrate cell types while supporting a wide variety of cellular assays.

  19. Rapid Industrial Prototyping and SoC Design of 3G/4G Wireless Systems Using an HLS Methodology

    Directory of Open Access Journals (Sweden)

    Andres Takach

    2006-07-01

    Full Text Available Many very-high-complexity signal processing algorithms are required in future wireless systems, giving tremendous challenges to real-time implementations. In this paper, we present our industrial rapid prototyping experiences on 3G/4G wireless systems using advanced signal processing algorithms in MIMO-CDMA and MIMO-OFDM systems. Core system design issues are studied and advanced receiver algorithms suitable for implementation are proposed for synchronization, MIMO equalization, and detection. We then present VLSI-oriented complexity reduction schemes and demonstrate how to interact these high-complexity algorithms with an HLS-based methodology for extensive design space exploration. This is achieved by abstracting the main effort from hardware iterations to the algorithmic C/C++ fixed-point design. We also analyze the advantages and limitations of the methodology. Our industrial design experience demonstrates that it is possible to enable an extensive architectural analysis in a short-time frame using HLS methodology, which significantly shortens the time to market for wireless systems.

  20. Rapid Industrial Prototyping and SoC Design of 3G/4G Wireless Systems Using an HLS Methodology

    Directory of Open Access Journals (Sweden)

    Cavallaro JosephR

    2006-01-01

    Full Text Available Many very-high-complexity signal processing algorithms are required in future wireless systems, giving tremendous challenges to real-time implementations. In this paper, we present our industrial rapid prototyping experiences on 3G/4G wireless systems using advanced signal processing algorithms in MIMO-CDMA and MIMO-OFDM systems. Core system design issues are studied and advanced receiver algorithms suitable for implementation are proposed for synchronization, MIMO equalization, and detection. We then present VLSI-oriented complexity reduction schemes and demonstrate how to interact these high-complexity algorithms with an HLS-based methodology for extensive design space exploration. This is achieved by abstracting the main effort from hardware iterations to the algorithmic C/C++ fixed-point design. We also analyze the advantages and limitations of the methodology. Our industrial design experience demonstrates that it is possible to enable an extensive architectural analysis in a short-time frame using HLS methodology, which significantly shortens the time to market for wireless systems.

  1. Assessing potential impacts of a wastewater rapid infiltration basin system on groundwater quality: a delaware case study.

    Science.gov (United States)

    Andres, A S; Sims, J Thomas

    2013-01-01

    Rapid infiltration basin systems (RIBS) are receiving increased interest for domestic wastewater disposal in rural areas. They rely on natural treatment processes to filter pollutants and use extremely high effluent loading rates, much greater than natural precipitation, applied to a small geographic area instead of disposal to surface water. Concerns exist today that adopting RIBS in areas with shallow groundwater and sandy soils may increase ground and surface water pollution. We conducted a field study of RIBS effects on N and P concentrations in soils and groundwater at Cape Henlopen State Park, Delaware, where a RIBS designed and operated following USEPA guidance has been used for >25 yr. Site and wastewater characteristics (water table of 8 m, Fe- and Al-oxide coatings on soils, organic-rich effluent) were favorable for denitrification and P sorption; however, we found high P saturation, reduced soil P sorption capacity, and significant total P accumulation at depths >1.5 m, factors that could lead to dissolved P leaching. Very low soil inorganic N levels suggest that wastewater N was converted rapidly to NO-N and leached from the RIBS. Extensive groundwater monitoring supported these concerns and showed rapid offsite transport of N and P at concentrations similar to the effluent. Results suggest that high hydraulic loads and preferential flow led to flow velocities that were too large, and contact times between effluent and soils that were too short, for effective N and P attenuation processes. These findings indicate the need for better site characterization and facility designs to reduce and monitor contaminant loss from RIBS in similar settings. Copyright © by the American Society of Agronomy, Crop Science Society of America, and Soil Science Society of America, Inc.

  2. Rapid prototyping of an automated video surveillance system: a hardware-software co-design approach

    Science.gov (United States)

    Ngo, Hau T.; Rakvic, Ryan N.; Broussard, Randy P.; Ives, Robert W.

    2011-06-01

    FPGA devices with embedded DSP and memory blocks, and high-speed interfaces are ideal for real-time video processing applications. In this work, a hardware-software co-design approach is proposed to effectively utilize FPGA features for a prototype of an automated video surveillance system. Time-critical steps of the video surveillance algorithm are designed and implemented in the FPGAs logic elements to maximize parallel processing. Other non timecritical tasks are achieved by executing a high level language program on an embedded Nios-II processor. Pre-tested and verified video and interface functions from a standard video framework are utilized to significantly reduce development and verification time. Custom and parallel processing modules are integrated into the video processing chain by Altera's Avalon Streaming video protocol. Other data control interfaces are achieved by connecting hardware controllers to a Nios-II processor using Altera's Avalon Memory Mapped protocol.

  3. Small Tactical Unmanned Aerial System (STUAS) Rapid Integration and Fielding Process (RAIN)

    Science.gov (United States)

    2013-09-01

    standard operating mode in each context 4 N/A • Standard maintenance modes of the system 5 NIA • Standard resupply modes of the ~ stem 6 Lack of, or...34~~utroc j 851,3 % ~ .... ~QbliiC(t~OI’Ihl\\ol"’QQ’- :ll ~rANtt (£ Mt6:M 0 ltl~ ::J lt.dQ....,.It ~Oeti~ Cll «t)(.f.xi~ .!_!!:t ~e 4 ~ Sla6slks ~ - «n...ShcMIN~QbtiiC(t~OI’I--hotqr- ~ IrANI’\\ {Z Mt6:M 0 ltt~ .:J ltdQ....,.It ~Oeti~ Cll «t)(.f.xi~ !.J!! ~e t It! Slrisks .!.......!:. - C<nu< 319

  4. Systemic range shift lags among a pollinator species assemblage following rapid climate change

    DEFF Research Database (Denmark)

    Bedford, Felicity E.; Whittaker, Robert J.; Kerr, Jeremy T.

    2012-01-01

    Contemporary climate change is driving widespread geographical range shifts among many species. If species are tracking changing climate successfully, then leading populations should experience similar climatic conditions through time as new populations establish beyond historical range margins....... Here, we investigate geographical range shifts relative to changing climatic conditions among a particularly well-sampled assemblage of butterflies in Canada. We assembled observations of 81 species and measured their latitudinal displacement between two periods: 1960–1975 (a period of little climate...... change) and 1990–2005 (a period with large climate change). We find an unexpected trend for species’ northern borders to shift progressively less relative to increasing minimum winter temperatures in northern Canada. This study demonstrates a novel, systemic latitudinal gradient in lags among a large...

  5. MALDI-TOF MS is more accurate than VITEK II ANC card and API Rapid ID 32 A system for the identification of Clostridium species.

    Science.gov (United States)

    Kim, Young Jin; Kim, Si Hyun; Park, Hyun-Jung; Park, Hae-Geun; Park, Dongchul; Song, Sae Am; Lee, Hee Joo; Yong, Dongeun; Choi, Jun Yong; Kook, Joong-Ki; Kim, Hye Ran; Shin, Jeong Hwan

    2016-08-01

    All 50 Clostridium difficile strains were definitely identified by Vitek2 system, Rapid ID 32A system, and MALDI-TOF. For 18 non-difficile Clostridium strains, the identification results were correct in 0, 2, and 17 strains by Vitek2, Rapid ID 32A, and MALDI-TOF, respectively. MALDI-TOF could be used as the primary tool for identification of Clostridium species. Copyright © 2016 Elsevier Ltd. All rights reserved.

  6. High throughput automated microbial bioreactor system used for clone selection and rapid scale-down process optimization.

    Science.gov (United States)

    Velez-Suberbie, M Lourdes; Betts, John P J; Walker, Kelly L; Robinson, Colin; Zoro, Barney; Keshavarz-Moore, Eli

    2018-01-01

    High throughput automated fermentation systems have become a useful tool in early bioprocess development. In this study, we investigated a 24 x 15 mL single use microbioreactor system, ambr 15f, designed for microbial culture. We compared the fed-batch growth and production capabilities of this system for two Escherichia coli strains, BL21 (DE3) and MC4100, and two industrially relevant molecules, hGH and scFv. In addition, different carbon sources were tested using bolus, linear or exponential feeding strategies, showing the capacity of the ambr 15f system to handle automated feeding. We used power per unit volume (P/V) as a scale criterion to compare the ambr 15f with 1 L stirred bioreactors which were previously scaled-up to 20 L with a different biological system, thus showing a potential 1,300 fold scale comparability in terms of both growth and product yield. By exposing the cells grown in the ambr 15f system to a level of shear expected in an industrial centrifuge, we determined that the cells are as robust as those from a bench scale bioreactor. These results provide evidence that the ambr 15f system is an efficient high throughput microbial system that can be used for strain and molecule selection as well as rapid scale-up. © 2017 The Authors Biotechnology Progress published by Wiley Periodicals, Inc. on behalf of American Institute of Chemical Engineers Biotechnol. Prog., 34:58-68, 2018. © 2017 The Authors Biotechnology Progress published by Wiley Periodicals, Inc. on behalf of American Institute of Chemical Engineers.

  7. Synaptic inputs compete during rapid formation of the calyx of Held: a new model system for neural development.

    Science.gov (United States)

    Holcomb, Paul S; Hoffpauir, Brian K; Hoyson, Mitchell C; Jackson, Dakota R; Deerinck, Thomas J; Marrs, Glenn S; Dehoff, Marlin; Wu, Jonathan; Ellisman, Mark H; Spirou, George A

    2013-08-07

    Hallmark features of neural circuit development include early exuberant innervation followed by competition and pruning to mature innervation topography. Several neural systems, including the neuromuscular junction and climbing fiber innervation of Purkinje cells, are models to study neural development in part because they establish a recognizable endpoint of monoinnervation of their targets and because the presynaptic terminals are large and easily monitored. We demonstrate here that calyx of Held (CH) innervation of its target, which forms a key element of auditory brainstem binaural circuitry, exhibits all of these characteristics. To investigate CH development, we made the first application of serial block-face scanning electron microscopy to neural development with fine temporal resolution and thereby accomplished the first time series for 3D ultrastructural analysis of neural circuit formation. This approach revealed a growth spurt of added apposed surface area (ASA)>200 μm2/d centered on a single age at postnatal day 3 in mice and an initial rapid phase of growth and competition that resolved to monoinnervation in two-thirds of cells within 3 d. This rapid growth occurred in parallel with an increase in action potential threshold, which may mediate selection of the strongest input as the winning competitor. ASAs of competing inputs were segregated on the cell body surface. These data suggest mechanisms to select "winning" inputs by regional reinforcement of postsynaptic membrane to mediate size and strength of competing synaptic inputs.

  8. Development of microLIPS (Luciferase Immunoprecipitation Systems): a novel microfluidic assay for rapid serum antibody detection

    Science.gov (United States)

    Chandrangsu, Matt; Burbelo, Peter D.; Iadarola, Michael J.; Smith, Paul D.; Morgan, Nicole Y.

    2012-06-01

    There is considerable interest in the development of rapid, point-of-care antibody detection for the diagnosis of infectious and auto-immune diseases. In this paper, we present work on the development of a self-contained microfluidic format for the Luciferase Immunoprecipitation Systems (LIPS) assay. Whereas the majority of immunoassays for antigen-specific antibodies employ either bacteria- or yeast-expressed proteins and require the use of secondary antibodies, the LIPS technique uses a fusion protein comprised of a Renilla luciferase reporter and the antigen of interest produced via mammalian cell culture, ensuring the addition of mammalian post-translational modifications. Patient serum is mixed with the fusion protein and passed over immobilized Protein A/G; after washing, the only remaining luciferase-tagged antigens are those retained by specific antibodies. These can be quantitatively measured using chemiluminescence upon the introduction of coelenterazine. The assay has been successfully employed for a wide variety of diseases in a microwell format. We report on a recent demonstration of rapid HSV-2 diagnosis with the LIPS assay in a microfluidic format, using one microliter of serum and obtaining results in under ten minutes. We will also discuss recent progress on two fronts, both aimed at the deployment of this technology in the field: first, simplifying assay operation through the automation of flow control using power-free means; and second, efforts to increase signal levels, primarily through strategies to increase antibody binding capacity, in order to move towards portable battery powered electronics.

  9. A rapid pathway toward a superb gene delivery system: programming structural and functional diversity into a supramolecular nanoparticle library.

    Science.gov (United States)

    Wang, Hao; Liu, Kan; Chen, Kuan-Ju; Lu, Yujie; Wang, Shutao; Lin, Wei-Yu; Guo, Feng; Kamei, Ken-ichiro; Chen, Yi-Chun; Ohashi, Minori; Wang, Mingwei; Garcia, Mitch André; Zhao, Xing-Zhong; Shen, Clifton K-F; Tseng, Hsian-Rong

    2010-10-26

    Nanoparticles are regarded as promising transfection reagents for effective and safe delivery of nucleic acids into a specific type of cells or tissues providing an alternative manipulation/therapy strategy to viral gene delivery. However, the current process of searching novel delivery materials is limited due to conventional low-throughput and time-consuming multistep synthetic approaches. Additionally, conventional approaches are frequently accompanied with unpredictability and continual optimization refinements, impeding flexible generation of material diversity creating a major obstacle to achieving high transfection performance. Here we have demonstrated a rapid developmental pathway toward highly efficient gene delivery systems by leveraging the powers of a supramolecular synthetic approach and a custom-designed digital microreactor. Using the digital microreactor, broad structural/functional diversity can be programmed into a library of DNA-encapsulated supramolecular nanoparticles (DNA⊂SNPs) by systematically altering the mixing ratios of molecular building blocks and a DNA plasmid. In vitro transfection studies with DNA⊂SNPs library identified the DNA⊂SNPs with the highest gene transfection efficiency, which can be attributed to cooperative effects of structures and surface chemistry of DNA⊂SNPs. We envision such a rapid developmental pathway can be adopted for generating nanoparticle-based vectors for delivery of a variety of loads.

  10. Assessing health systems for type 1 diabetes in sub-Saharan Africa: developing a 'Rapid Assessment Protocol for Insulin Access'

    Directory of Open Access Journals (Sweden)

    de Courten Maximilian

    2006-02-01

    Full Text Available Abstract Background In order to improve the health of people with Type 1 diabetes in developing countries, a clear analysis of the constraints to insulin access and diabetes care is needed. We developed a Rapid Assessment Protocol for Insulin Access, comprising a series of questionnaires as well as a protocol for the gathering of other data through site visits, discussions, and document reviews. Methods The Rapid Assessment Protocol for Insulin Access draws on the principles of Rapid Assessment Protocols which have been developed and implemented in several different areas. This protocol was adapted through a thorough literature review on diabetes, chronic condition management and medicine supply in developing countries. A visit to three countries in sub-Saharan Africa and meetings with different experts in the field of diabetes helped refine the questionnaires. Following the development of the questionnaires these were tested with various people familiar with diabetes and/or healthcare in developing countries. The Protocol was piloted in Mozambique then refined and had two further iterations in Zambia and Mali. Translations of questionnaires were made into local languages when necessary, with back translation to ensure precision. Results In each country the protocol was implemented in 3 areas – the capital city, a large urban centre and a predominantly rural area and their respective surroundings. Interviews were carried out by local teams trained on how to use the tool. Data was then collected and entered into a database for analysis. Conclusion The Rapid Assessment Protocol for Insulin Access was developed to provide a situational analysis of Type 1 diabetes, in order to make recommendations to the national Ministries of Health and Diabetes Associations. It provided valuable information on patients' access to insulin, syringes, monitoring and care. It was thus able to sketch a picture of the health care system with regards to its ability to

  11. Rapid maxillary distraction protocol utilizing the halo distraction system and rigid internal fixation.

    Science.gov (United States)

    Baker, Stephen B; Reid, Russell R; Burkey, Brooke; Bartlett, Scott P

    2007-09-01

    To shorten head frame wear time associated with external halo distraction (HD), we have adapted a protocol for maxillary distraction with the halo system that integrates plate fixation. All patients had a history of cleft lip and/or palate and maxillary retrusion > or = 8 mm. Five patients treated with this protocol and followed for at least 1 year were included in this study. The protocol included a 3-day latency period, variable maxillary distraction, and removal of the halo device with simultaneous rigid internal fixation. Two patients had a variable period of maxillomandibular fixation (MMF), which maintained the maxillary advancement and idealized intercuspal position while permitting further callus maturation. Cephalographs were obtained preoperatively, immediately following distractor removal, and 1 year after rigid internal fixation. The mean age at time of surgery was 18.7 years. The maxillary deficiency ranged from 8 to 15 mm (mean = 10.6 mm). All five patients demonstrated excellent occlusion. Cephalometric analysis 1-year post rigid internal fixation revealed minimal (maxillary distraction followed by MMF to maintain maxillary advancement may reduce halo device wear to 1 to 2 weeks. MMF optimizes occlusion by forcing the maxillary teeth into maximal intercuspal position. Rigid fixation is not only associated with less long-term relapse compared to nonrigid forms of fixation, but also minimizes the incidence of nonunion. This treatment protocol provides the advancement possible with distraction osteogenesis and the accuracy of orthognathic surgery, thereby minimizing external head frame wear.

  12. New method for rapid Susceptibility Testing on blood culture with HB&L system: preliminary data

    Directory of Open Access Journals (Sweden)

    Vincenzo Rondinelli

    2010-12-01

    Full Text Available Blood culture, although represents the gold standard in detecting the ethiological agent of sepsis, is rather rarely required in relation to the real diagnostic importance. The result of this test depends in fact on many factors (sample volume, time of collection, accuracy, antibiotic therapy, contamination, number of drawings, drawing site, interpretation difficulties, etc. that are often considered by many clinicians so limited as to doubt about their actual value. The disadvantages are therefore represented by the lack of standardization but also by the low sensitivity and above all by the technical times too long for the clinical needs. Blood culture begins with the drawing of samples from the “septic” patient followed incubation of the bottles in automatic thermostated systems. In case of positive result (36 hours, the culture is Gram stained and streaked on solid media in order to obtain isolated colonies for the identification and the susceptibility testing (48 hours from positive result. The long time required for pathogen identification and susceptibility testing involves empirical broad spectrum antibiotic therapy that can promote the increase of bacterial resistance but also patient management costs. A clinically useful report should be available on short notice in order to guide the clinician to choose the most appropriate antibiotic. The microbiologist has therefore the hard work of reviewing the organization and the management of the procedures.We have therefore started to consider the possibility of treating the blood as an biological liquid in order to quickly determine the susceptibility of bacteria to antibiotics.

  13. Rapid infusion with rituximab: short term safety in systemic autoimmune diseases

    DEFF Research Database (Denmark)

    Larsen, Janni Lisander; Jacobsen, Soren

    2013-01-01

    To describe the incidence, types and severity of adverse events, related to an accelerated regime of rituximab infusion in patients with various autoimmune diseases. Fifty-four patients with systemic autoimmune disease, to be treated with 1,000 mg of rituximab twice 2 weeks apart, participated. Pre......-medication (oral prednisolone, anti-histamine and paracetamol) was administered 1-4 h before infusion start. The first infusion was administered over a period of 195 min. The second infusion over a period of 90 min. Any adverse events were classified using the Clinical Trials Classification of Adverse Events...... (CTCAE) v. 3.0. Ten patients (18.5%) experienced at least one infusion-related reaction (IRR) ever. The first infusion was associated with reactions in 4 CTCAE categories of which rhinitis were the most frequent. The CTCAE severity grading showed six patients (11.1%) had a grade 1 reaction. One patient...

  14. Low-Cost Rapid Usability Testing: Its Application in Both Product Development and System Implementation.

    Science.gov (United States)

    Kushniruk, Andre; Borycki, Elizabeth

    2017-01-01

    In recent years there has been considerable discussion around the need for certification and regulation of healthcare information technology (IT). In particular, the usability of the products being developed needs to be evaluated. This has included the application of standards designed to ensure the process of system development is user-centered and takes usability into consideration while a product is being developed. In addition to this, in healthcare, organizations in the United States and Europe have also addressed the need and requirement for product certification. However, despite these efforts there are continued reports of unusable and unsafe implementations. In this paper we discuss the need to not only include (and require) usability testing in the one-time development process of health IT products (such as EHRs), but we also argue for the need to additionally develop specific usability standards and requirements for usability testing during the implementation of vendor products (i.e. post product development) in healthcare settings. It is further argued that health IT products that may have been certified regarding their development process will still require application of usability testing in the process of implementing them in real hospital settings in order to ensure usability and safety. This is needed in order to ensure that the final result of both product development and implementation processes take into account and apply the latest usability principles and methods.

  15. Rapid and highly integrated FPGA-based Shack-Hartmann wavefront sensor for adaptive optics system

    Science.gov (United States)

    Chen, Yi-Pin; Chang, Chia-Yuan; Chen, Shean-Jen

    2018-02-01

    In this study, a field programmable gate array (FPGA)-based Shack-Hartmann wavefront sensor (SHWS) programmed on LabVIEW can be highly integrated into customized applications such as adaptive optics system (AOS) for performing real-time wavefront measurement. Further, a Camera Link frame grabber embedded with FPGA is adopted to enhance the sensor speed reacting to variation considering its advantage of the highest data transmission bandwidth. Instead of waiting for a frame image to be captured by the FPGA, the Shack-Hartmann algorithm are implemented in parallel processing blocks design and let the image data transmission synchronize with the wavefront reconstruction. On the other hand, we design a mechanism to control the deformable mirror in the same FPGA and verify the Shack-Hartmann sensor speed by controlling the frequency of the deformable mirror dynamic surface deformation. Currently, this FPGAbead SHWS design can achieve a 266 Hz cyclic speed limited by the camera frame rate as well as leaves 40% logic slices for additionally flexible design.

  16. Development and Verification of a Mobile Shelter Assessment System "Rapid Assessment System of Evacuation Center Condition Featuring Gonryo and Miyagi (RASECC-GM)" for Major Disasters.

    Science.gov (United States)

    Ishii, Tadashi; Nakayama, Masaharu; Abe, Michiaki; Takayama, Shin; Kamei, Takashi; Abe, Yoshiko; Yamadera, Jun; Amito, Koichiro; Morino, Kazuma

    2016-10-01

    Introduction There were 5,385 deceased and 710 missing in the Ishinomaki medical zone following the Great East Japan Earthquake that occurred in Japan on March 11, 2011. The Ishinomaki Zone Joint Relief Team (IZJRT) was formed to unify the relief teams of all organizations joining in support of the Ishinomaki area. The IZJRT expanded relief activity as they continued to manually collect and analyze assessments of essential information for maintaining health in all 328 shelters using a paper-type survey. However, the IZJRT spent an enormous amount of time and effort entering and analyzing these data because the work was vastly complex. Therefore, an assessment system must be developed that can tabulate shelter assessment data correctly and efficiently. The objective of this report was to describe the development and verification of a system to rapidly assess evacuation centers in preparation for the next major disaster. Report Based on experiences with the complex work during the disaster, software called the "Rapid Assessment System of Evacuation Center Condition featuring Gonryo and Miyagi" (RASECC-GM) was developed to enter, tabulate, and manage the shelter assessment data. Further, a verification test was conducted during a large-scale Self-Defense Force (SDF) training exercise to confirm its feasibility, usability, and accuracy. The RASECC-GM comprises three screens: (1) the "Data Entry screen," allowing for quick entry on tablet devices of 19 assessment items, including shelter administrator, living and sanitary conditions, and a tally of the injured and sick; (2) the "Relief Team/Shelter Management screen," for registering information on relief teams and shelters; and (3) the "Data Tabulation screen," which allows tabulation of the data entered for each shelter, as well as viewing and sorting from a disaster headquarters' computer. During the verification test, data of mock shelters entered online were tabulated quickly and accurately on a mock disaster

  17. Human adaptation responses to a rapidly changing Arctic: A research context for building system resilience

    Science.gov (United States)

    Chapin, T.; Brinkman, T. J.

    2016-12-01

    these actors in the research process could strongly influence the resilience of arctic social-ecological systems to climate change.

  18. Rapid prototyping systems for the development of new fuel-injection concepts for diesel engines; Einspritz-Prototyping-System zur Entwicklung neuer Einspritzkonzepte bei Dieselmotoren

    Energy Technology Data Exchange (ETDEWEB)

    Kasper, M. [ETAS GmbH, Stuttgart (Germany)

    2004-10-01

    The article uses the example of solenoid-based fuel injectors for diesel engines to demonstrate how a combination of reconfigurable logic and microcontrollers may be employed towards the rapid implementation of new control concepts for timely testing either directly on the engine or in the vehicle. Emphasis is given to the development and optimization of electronic engine management components. In contrast to the nonexistent modification options on conventional production ECUs, the new concept allows for the modification and fine-tuning of a number of injection parameters. The rapid prototyping system is a joint development of the Research and Advanced Engineering Department of Robert Bosch GmbH and ETAS GmbH. (orig.)

  19. Rapid prototyping of SoC-based real-time vision system: application to image preprocessing and face detection

    Science.gov (United States)

    Jridi, Maher; Alfalou, Ayman

    2017-05-01

    By this paper, the major goal is to investigate the Multi-CPU/FPGA SoC (System on Chip) design flow and to transfer a know-how and skills to rapidly design embedded real-time vision system. Our aim is to show how the use of these devices can be benefit for system level integration since they make possible simultaneous hardware and software development. We take the facial detection and pretreatments as case study since they have a great potential to be used in several applications such as video surveillance, building access control and criminal identification. The designed system use the Xilinx Zedboard platform. The last is the central element of the developed vision system. The video acquisition is performed using either standard webcam connected to the Zedboard via USB interface or several camera IP devices. The visualization of video content and intermediate results are possible with HDMI interface connected to HD display. The treatments embedded in the system are as follow: (i) pre-processing such as edge detection implemented in the ARM and in the reconfigurable logic, (ii) software implementation of motion detection and face detection using either ViolaJones or LBP (Local Binary Pattern), and (iii) application layer to select processing application and to display results in a web page. One uniquely interesting feature of the proposed system is that two functions have been developed to transmit data from and to the VDMA port. With the proposed optimization, the hardware implementation of the Sobel filter takes 27 ms and 76 ms for 640x480, and 720p resolutions, respectively. Hence, with the FPGA implementation, an acceleration of 5 times is obtained which allow the processing of 37 fps and 13 fps for 640x480, and 720p resolutions, respectively.

  20. Influence of system controls on the Late Quaternary geomorphic evolution of a rapidly-infilled incised-valley system: The lower Manawatu valley, North Island New Zealand

    Science.gov (United States)

    Clement, Alastair J. H.; Fuller, Ian C.

    2018-02-01

    The Manawatu incised-valley estuary was rapidly infilled between 12,000-4700 cal. yr BP. A combination of empirical measurements of sedimentation rates, a reconstruction of relative sea-level (RSL) change, and digital elevation models of key surfaces within the Holocene sedimentary fill of the valley were integrated to produce a numerical model to investigate the influence of the system controls of sea-level change, sediment flux, and accommodation space on the rapid infilling history of the palaeo-estuary. The numerical model indicates that sediment flux into the palaeo-estuary was greatest during the Holocene marine transgression between 12,000-8000 years BP. The average rate of sediment deposition in the estuary during this period was 1.0 M m3 yr- 1. This rapid rate of sedimentation was controlled by the rate of accommodation space creation, as regulated by the rate of sea-level rise and the antecedent configuration of the valley. By the time sea levels stabilised c. 7500 cal. yr BP, the palaeo-estuary had been substantively infilled. Limited accommodation space resulted in rapid infilling of the central basin, though sediment flux into the estuary between 7100 and 4500 cal. yr BP was at a lower rate of 234,000 m3 yr- 1. The limited accommodation space also influenced hydrodynamic conditions in the estuarine central basin, driving export of fine-grained sediment from the estuary. Once the accommodation space of the estuarine basin was infilled sediment bypassed the system, with a consequent reduction in the sedimentation rate in the valley. More accurate partitioning of the sources of sediment driving the infilling is necessary to quantify sediment bypassing. Post-depositional lowering of RSL index points from the valley is driven by neotectonics and sediment compaction.

  1. Large-timestep techniques for particle-in-cell simulation of systems with applied fields that vary rapidly in space

    International Nuclear Information System (INIS)

    Friedman, A.; Grote, D.P.

    1996-10-01

    Under conditions which arise commonly in space-charge-dominated beam applications, the applied focusing, bending, and accelerating fields vary rapidly with axial position, while the self-fields (which are, on average, comparable in strength to the applied fields) vary smoothly. In such cases it is desirable to employ timesteps which advance the particles over distances greater than the characteristic scales over which the applied fields vary. Several related concepts are potentially applicable: sub-cycling of the particle advance relative to the field solution, a higher-order time-advance algorithm, force-averaging by integration along approximate orbits, and orbit-averaging. We report on our investigations into the utility of such techniques for systems typical of those encountered in accelerator studies for heavy-ion beam-driven inertial fusion

  2. Rapid radiometric detection of microbial contamination using 14C-glucose and standard liquid scintillation counting system

    International Nuclear Information System (INIS)

    Joshi, S.H.; Kamble, S.B.; Pilkhwal, N.S.; Ramamoorthy, N.

    1998-01-01

    A simple and rapid method for detection of microbial contamination based on quantitation of 14 CO 2 released during metabolism of 14 C-Glucose by microorganisms is reported. Liquid scintillation counting system (LSCS) with a modified sample preparation method was utilised. The scintillator was impregnated on Whatman-1 paper on which 14 CO 2 evolved during metabolism could be absorbed. The important parameters of counting such as efficiency, position sensitivity and geometry as well as effect of NaOH quantity and of microbial load on detection period were studied. The efficiency of radioactivity assay was 18±2.8 %. Contamination of the order of 5-10 organism/ml of product could be detected in about 24 hours. (author)

  3. Significant air embolism: A possibility even with collapsible intravenous fluid containers when used with rapid infuser system

    Science.gov (United States)

    Pant, Deepanjali; Narani, Krishan Kumar; Sood, Jayashree

    2010-01-01

    Significant venous air embolism may develop acutely during the perioperative period due to a number of causes such as during head and neck surgery, spinal surgery, improper central venous and haemodialysis catheter handling, etc. The current trend of using self collapsible intravenous (IV) infusion bags instead of the conventional glass or plastic bottles has several advantages, one of thaem being protection against air embolism. We present a 56-year-old man undergoing kidney transplantation, who developed a near fatal venous air embolism during volume resuscitation with normal saline in collapsible IV bags used with rapid infuser system. To our knowledge, this problem with collapsible infusion bags has not been reported earlier. PMID:20532073

  4. Significant air embolism: A possibility even with collapsible intravenous fluid containers when used with rapid infuser system

    Directory of Open Access Journals (Sweden)

    Deepanjali Pant

    2010-01-01

    Full Text Available Significant venous air embolism may develop acutely during the perioperative period due to a number of causes such as during head and neck surgery, spinal surgery, improper central venous and haemodialysis catheter handling, etc. The current trend of using self collapsible intravenous (IV infusion bags instead of the conventional glass or plastic bottles has several advantages, one of thaem being protection against air embolism. We present a 56-year-old man undergoing kidney transplantation, who developed a near fatal venous air embolism during volume resuscitation with normal saline in collapsible IV bags used with rapid infuser system. To our knowledge, this problem with collapsible infusion bags has not been reported earlier.

  5. Threshold and resilience management of coupled urbanization and water environmental system in the rapidly changing coastal region.

    Science.gov (United States)

    Li, Yangfan; Li, Yi; Wu, Wei

    2016-01-01

    The concept of thresholds shows important implications for environmental and resource management. Here we derived potential landscape thresholds which indicated abrupt changes in water quality or the dividing points between exceeding and failing to meet national surface water quality standards for a rapidly urbanizing city on the Eastern Coast in China. The analysis of landscape thresholds was based on regression models linking each of the seven water quality variables to each of the six landscape metrics for this coupled land-water system. We found substantial and accelerating urban sprawl at the suburban areas between 2000 and 2008, and detected significant nonlinear relations between water quality and landscape pattern. This research demonstrated that a simple modeling technique could provide insights on environmental thresholds to support more-informed decision making in land use, water environmental and resilience management. Copyright © 2015 Elsevier Ltd. All rights reserved.

  6. Rapid movement of wastewater from on-site disposal systems into surface waters in the lower Florida Keys

    Science.gov (United States)

    Paul, John H.; McLaughlin, Molly R.; Griffin, Dale W.; Lipp, Erin K.; Stokes, Rodger; Rose, Joan B.

    2000-01-01

    Viral tracer studies have been used previously to study the potential for wastewater contamination of surface marine waters in the Upper and Middle Florida Keys. Two bacteriophages, the marine bacteriophage φHSIC and the Salmonella phage PRD1, were used as tracers in injection well and septic tank studies in Saddlebunch Keys of the Lower Florida Keys and in septic tank studies in Boot Key Harbor, Marathon, of the Middle Keys. In Boot Key Harbor, both phages were detected in a canal adjacent to the seeded septic tank within 3 h 15 min of the end of the seed period. The tracer was then detected at all sampling sites in Boot Key Harbor, including one on the opposite side of U. S. Highway 1 in Florida Bay, and at an Atlantic Ocean beach outside Boot Key Harbor. Rates of migration based on first appearance of the phage ranged from 1.7 to 57.5 m h-1. In Saddlebunch Keys, φHSIC and PRD1 were used to seed a residential septic tank and a commercial injection well. The septic tank tracer was not found in any surface water samples. The injection well tracer was first detected at a site most distant from the seed site, a channel that connected Sugarloaf Sound with the Atlantic Ocean. The rate of tracer migration from the injection well to this channel ranged from 66.8 to 141 m h-1. Both tracer studies showed a rapid movement of wastewater from on-site sewage treatment and disposal systems in a southeasterly direction toward the reef tract and Atlantic Ocean, with preferential movement through tidal channels. These studies indicate that wastewater disposal systems currently in widespread use in the Florida Keys can rapidly contaminate the marine environment.

  7. Rapid Analyses of Polyetheretherketone Wear Characteristics by Accelerated Wear Testing with Microfabricated Surfaces for Artificial Joint Systems.

    Science.gov (United States)

    Su, Chen-Ying; Kuo, Chien-Wei; Fang, Hsu-Wei

    2017-01-01

    Wear particle-induced biological responses are the major factors resulting in the loosening and then failure of total joint arthroplasties. It is feasible to improve the lubrication and reduce the wear of artificial joint system. Polyetheretherketone (PEEK) is considered as a potential bearing material due to its mechanical characteristics of resistance to fatigue strain. The PEEK wear particles have been indicated to be involved in biological responses in vitro, and further studies regarding the wear phenomena and wear particle generation are needed. In this study, we have established an accelerated wear testing system with microfabricated surfaces. Various contact pressures and lubricants have been utilized in the accelerated wear tests. Our results showed that increasing contact pressure resulted in an increase of wear particle sizes and wear rate, and the size of PEEK wear particles can be controlled by the feature size of microfabricated surfaces. These results provided the information rapidly about factors that affect the morphology and amount of PEEK wear particles and can be applied in the future for application of PEEK on the biological articulation system.

  8. Application of Rapid Prototyping Technique and Intraoperative Navigation System for the Repair and Reconstruction of Orbital Wall Fractures

    Science.gov (United States)

    Cha, Jong Hyun; Lee, Yong Hae; Ruy, Wan Chul; Roe, Young; Moon, Myung Ho

    2016-01-01

    Background Restoring the orbital cavity in large blow out fractures is a challenge for surgeons due to the anatomical complexity. This study evaluated the clinical outcomes and orbital volume after orbital wall fracture repair using a rapid prototyping (RP) technique and intraoperative navigation system. Methods This prospective study was conducted on the medical records and radiology records of 12 patients who had undergone a unilateral blow out fracture reconstruction using a RP technique and an intraoperative navigation system from November 2014 to March 2015. The surgical results were assessed by an ophthalmic examination and a comparison of the preoperative and postoperative orbital volume ratio (OVR) values. Results All patients had a successful treatment outcome without complications. Volumetric analysis revealed a significant decrease in the mean OVR from 1.0952±0.0662 (ranging from 0.9917 to 1.2509) preoperatively to 0.9942±0.0427 (ranging from 0.9394 to 1.0680) postoperatively. Conclusion The application of a RP technique for the repair of orbital wall fractures is a useful tool that may help improve the clinical outcomes by understanding the individual anatomy, determining the operability, and restoring the orbital cavity volume through optimal implant positioning along with an intraoperative navigation system. PMID:28913272

  9. Rapid Cultural Change: A Case Study of Polyandry Marriage System among the Gurung Community from Upper Mustang, Nepal

    Directory of Open Access Journals (Sweden)

    Juddha Bahadur Gurung

    2013-08-01

    Full Text Available Nepal is multi ethnic, multi lingual and multi cultural country. In Upper Mustang polyandry is practiced by Loba communities. However, the condition of polyandry is dying out at present. The young are not in favor of this system. Socio-economic, political, seasonal migration, tourism and developmental factors have played crucial role in this regards. From conservation perspective polyandry played crucial role to manage local resources and in population dynamics in the past. This paper is based on field survey carried out in two different time periods (1998 and 2008 in order to compare or understand changing pattern of polyandry. In last couple of years, polyandry system has changed very rapidly in Loba communities of Upper Mustang. Rising community awareness, multiple economic opportunities, improve communication, foreign employment, modern education, open tourism, road access and other visual and in visual forces has lead society from close to open and more wider side or increase the horizon of young generation. Polyandry system is directly affected. DOI: http://dx.doi.org/10.3126/dsaj.v6i0.8480 Dhaulagiri Journal of Sociology and Anthropology Vol. 6, 2012 75-106

  10. Development of rapid, continuous calibration techniques and implementation as a prototype system for civil engineering materials evaluation

    International Nuclear Information System (INIS)

    Scott, M. L.; Gagarin, N.; Mekemson, J. R.; Chintakunta, S. R.

    2011-01-01

    Until recently, civil engineering material calibration data could only be obtained from material sample cores or via time consuming, stationary calibration measurements in a limited number of locations. Calibration data are used to determine material propagation velocities of electromagnetic waves in test materials for use in layer thickness measurements and subsurface imaging. Limitations these calibration methods impose have been a significant impediment to broader use of nondestructive evaluation methods such as ground-penetrating radar (GPR). In 2006, a new rapid, continuous calibration approach was designed using simulation software to address these measurement limitations during a Federal Highway Administration (FHWA) research and development effort. This continuous calibration method combines a digitally-synthesized step-frequency (SF)-GPR array and a data collection protocol sequence for the common midpoint (CMP) method. Modeling and laboratory test results for various data collection protocols and materials are presented in this paper. The continuous-CMP concept was finally implemented for FHWA in a prototype demonstration system called the Advanced Pavement Evaluation (APE) system in 2009. Data from the continuous-CMP protocol is processed using a semblance/coherency analysis to determine material propagation velocities. Continuously calibrated pavement thicknesses measured with the APE system in 2009 are presented. This method is efficient, accurate, and cost-effective.

  11. System for Rapid, Precise Modulation of Intraocular Pressure, toward Minimally-Invasive In Vivo Measurement of Intracranial Pressure.

    Directory of Open Access Journals (Sweden)

    Max A Stockslager

    Full Text Available Pathologic changes in intracranial pressure (ICP are commonly observed in a variety of medical conditions, including traumatic brain injury, stroke, brain tumors, and glaucoma. However, current ICP measurement techniques are invasive, requiring a lumbar puncture or surgical insertion of a cannula into the cerebrospinal fluid (CSF-filled ventricles of the brain. A potential alternative approach to ICP measurement leverages the unique anatomy of the central retinal vein, which is exposed to both intraocular pressure (IOP and ICP as it travels inside the eye and through the optic nerve; manipulating IOP while observing changes in the natural pulsations of the central retinal vein could potentially provide an accurate, indirect measure of ICP. As a step toward implementing this technique, we describe the design, fabrication, and characterization of a system that is capable of manipulating IOP in vivo with <0.1 mmHg resolution and settling times less than 2 seconds. In vitro tests were carried out to characterize system performance. Then, as a proof of concept, we used the system to manipulate IOP in tree shrews (Tupaia belangeri while video of the retinal vessels was recorded and the caliber of a selected vein was quantified. Modulating IOP using our system elicited a rapid change in the appearance of the retinal vein of interest: IOP was lowered from 10 to 3 mmHg, and retinal vein caliber sharply increased as IOP decreased from 7 to 5 mmHg. Another important feature of this technology is its capability to measure ocular compliance and outflow facility in vivo, as demonstrated in tree shrews. Collectively, these proof-of-concept demonstrations support the utility of this system to manipulate IOP for a variety of useful applications in ocular biomechanics, and provide a framework for further study of the mechanisms of retinal venous pulsation.

  12. Optical sensor system for time-resolved quantification of methane concentrations: Validation measurements in a rapid compression machine

    Science.gov (United States)

    Bauke, Stephan; Golibrzuch, Kai; Wackerbarth, Hainer; Fendt, Peter; Zigan, Lars; Seefeldt, Stefan; Thiele, Olaf; Berg, Thomas

    2018-05-01

    Lowering greenhouse gas emissions is one of the most challenging demands of today's society. Especially, the automotive industry struggles with the development of more efficient internal combustion (IC) engines. As an alternative to conventional fuels, methane has the potential for a significant emission reduction. In methane fuelled engines, the process of mixture formation, which determines the properties of combustion after ignition, differs significantly from gasoline and diesel engines and needs to be understood and controlled in order to develop engines with high efficiency. This work demonstrates the development of a gas sensing system that can serve as a diagnostic tool for measuring crank-angle resolved relative air-fuel ratios in methane-fuelled near-production IC engines. By application of non-dispersive infrared absorption spectroscopy at two distinct spectral regions in the ν3 absorption band of methane around 3.3 μm, the system is able to determine fuel density and temperature simultaneously. A modified spark plug probe allows for straightforward application at engine test stations. Here, the application of the detection system in a rapid compression machine is presented, which enables validation and characterization of the system on well-defined gas mixtures under engine-like dynamic conditions. In extension to a recent proof-of-principle study, a refined data analysis procedure is introduced that allows the correction of artefacts originating from mechanical distortions of the sensor probe. In addition, the measured temperatures are compared to data obtained with a commercially available system based on the spectrally resolved detection of water absorption in the near infrared.

  13. [A hydroponic cultivation system for rapid high-yield transient protein expression in Nicotiana plants under laboratory conditions].

    Science.gov (United States)

    Mo, Qianzhen; Mai, Rongjia; Yang, Zhixiao; Chen, Minfang; Yang, Tiezhao; Lai, Huafang; Yang, Peiliang; Chen, Qiang; Zhou, Xiaohong

    2012-06-01

    To develop a hydroponic Nicotiana cultivation system for rapid and high-yield transient expression of recombinant proteins under laboratory conditions. To establish the hydroponic cultivation system, several parameters were examined to define the optimal conditions for the expression of recombinant proteins in plants. We used the green fluorescent protein (GFP) and the geminiviral plant transient expression vector as the model protein/expression vector. We examined the impact of Nicotiana species, the density and time of Agrobacterium infiltration, and the post-infiltration growth period on the accumulation of GFP. The expression levels of GFP in Nicotiana leaves were then examined by Western blotting and ELISA. Our data indicated that a hydroponic Nicotiana cultivation system with a light intensity of 9000 LX/layer, a light cycle of 16 h day/8 h night, a temperature regime of 28 degrees celsius; day/21 degrees celsius; night, and a relative humidity of 80% could support the optimal plant growth and protein expression. After agroinfiltration with pBYGFPDsRed.R/LBA4404, high levels of GFP expression were observed in both N. benthamiana and N. tobaccum (cv. Yuyan No.5) plants cultured with this hydroponic cultivation system. An optimal GFP expression was achieved in both Nicotiana species leaves 4 days after infiltration by Agrobacterium with an OD(600) of 0.8. At a given time point, the average biomass of N. tobaccum (cv. Yuyan No.5) was significantly higher than that of N. benthamiana. The leaves from 6-week-old N. benthamiana plants and 5-week-old N. tobaccum (cv. Yuyan No.5) plants could be the optimal material for agroinfiltration. We have established a hydroponic cultivation system that allows robust growth of N. benthamiana and N. tobaccum (cv. Yuyan No.5) plants and the optimal GFP expression in the artificial climate box.

  14. Sistema de fabrico rápido de implantes ortopédicos Rapid manufacturing system of orthopedics implants

    Directory of Open Access Journals (Sweden)

    Carlos Relvas

    2009-06-01

    /CAM system. After sterilization, the implant is able to be placed on the patient. The concept was developed using low cost technology and commercially available. The system has been tested in an in vivo hip arthroplasty performed on a sheep. The time increase of surgery was 80 minutes being 40 minutes the time of implant manufacturing. The system developed has been tested and the goals defined of the study achieved enabling the rapid manufacture of an implant in a time period compatible with the surgery time.

  15. Interagency partnering for weed prevention--progress on development of a National Early Detection and Rapid Response System for Invasive Plants in the United States

    Science.gov (United States)

    Westbrooks, R.; Westbrooks, R.

    2011-01-01

    Over the past 50 years, experience has shown that interagency groups provide an effective forum for addressing various invasive species issues and challenges on multiple land units. However, more importantly, they can also provide a coordinated framework for early detection, reporting, identification and vouchering, rapid assessment, and rapid response to new and emerging invasive plants in the United States. Interagency collaboration maximizes the use of available expertise, resources, and authority for promoting early detection and rapid response (EDRR) as the preferred management option for addressing new and emerging invasive plants. Currently, an interagency effort is underway to develop a National EDRR System for Invasive Plants in the United States. The proposed system will include structural and informational elements. Structural elements of the system include a network of interagency partner groups to facilitate early detection and rapid response to new invasive plants, including the Federal Interagency Committee for the Management of Noxious and Exotic Weeds (FICMNEW), State Invasive Species Councils, State Early Detection and Rapid Response Coordinating Committees, State Volunteer Detection and Reporting Networks, Invasive Plant Task Forces, and Cooperative Weed Management Areas. Informational elements and products being developed include Regional Invasive Plant Atlases, and EDRR Guidelines for EDRR Volunteer Network Training, Rapid Assessment and Rapid Response, and Criteria for Selection of EDRR Species. System science and technical support elements which are provided by cooperating state and federal scientists, include EDRR guidelines, training curriculum for EDRR volunteers and agency field personnel, plant identification and vouchering, rapid assessments, as well as predictive modeling and ecological range studies for invasive plant species.

  16. Towards the development of a rapid, portable, surface enhanced Raman spectroscopy based cleaning verification system for the drug nelarabine.

    Science.gov (United States)

    Corrigan, Damion K; Salton, Neale A; Preston, Chris; Piletsky, Sergey

    2010-09-01

    Cleaning verification is a scientific and economic problem for the pharmaceutical industry. A large amount of potential manufacturing time is lost to the process of cleaning verification. This involves the analysis of residues on spoiled manufacturing equipment, with high-performance liquid chromatography (HPLC) being the predominantly employed analytical technique. The aim of this study was to develop a portable cleaning verification system for nelarabine using surface enhanced Raman spectroscopy (SERS). SERS was conducted using a portable Raman spectrometer and a commercially available SERS substrate to develop a rapid and portable cleaning verification system for nelarabine. Samples of standard solutions and swab extracts were deposited onto the SERS active surfaces, allowed to dry and then subjected to spectroscopic analysis. Nelarabine was amenable to analysis by SERS and the necessary levels of sensitivity were achievable. It is possible to use this technology for a semi-quantitative limits test. Replicate precision, however, was poor due to the heterogeneous drying pattern of nelarabine on the SERS active surface. Understanding and improving the drying process in order to produce a consistent SERS signal for quantitative analysis is desirable. This work shows the potential application of SERS for cleaning verification analysis. SERS may not replace HPLC as the definitive analytical technique, but it could be used in conjunction with HPLC so that swabbing is only carried out once the portable SERS equipment has demonstrated that the manufacturing equipment is below the threshold contamination level.

  17. Review of the investigation of mixture formation and combustion process using rapid compression machine and direct visualization system

    Science.gov (United States)

    Jaat, M.; Khalid, Amir; Manshoor, B.; Ramsy, Him

    2013-12-01

    This paper reviews of some applications of optical visualization systems to compute the fuel-air mixing process during early stage of mixture formation in Diesel Combustion Engines. A number of studies have contributed to the understanding of fuel air mixing in DI diesel engine. This review has shown that the mixture formation process affects initial flame development. The review also found that injection pressure has a great effect on the mixture formation then the flame development and combustion characteristics. The method of the simulation of real phenomenon of diesel combustion with optical access rapid compression machine is also reviewed and experimental results are presented. The application of these methods to the investigation of diesel sprays highlights mechanisms which govern propagation and distribution of the formation of a combustible fuel-air mixture. A summary of the implementation of constant volume chamber and optical visualization system are shown in the accompanying tables and figures. The visualization of the formation process of diesel spray and its combustion in the diesel combustion chamber of diesel engine has been recognized as one of the best ways to understand the characteristics of the mixture formation.

  18. Using agent based modeling to assess the effect of increased Bus Rapid Transit system infrastructure on walking for transportation.

    Science.gov (United States)

    Lemoine, Pablo D; Cordovez, Juan Manuel; Zambrano, Juan Manuel; Sarmiento, Olga L; Meisel, Jose D; Valdivia, Juan Alejandro; Zarama, Roberto

    2016-07-01

    The effect of transport infrastructure on walking is of interest to researchers because it provides an opportunity, from the public policy point of view, to increase physical activity (PA). We use an agent based model (ABM) to examine the effect of transport infrastructure on walking. Particular relevance is given to assess the effect of the growth of the Bus Rapid Transit (BRT) system in Bogotá on walking. In the ABM agents are assigned a home, work location, and socioeconomic status (SES) based on which they are assigned income for transportation. Individuals must decide between the available modes of transport (i.e., car, taxi, bus, BRT, and walking) as the means of reaching their destination, based on resources and needed travel time. We calibrated the model based on Bogota's 2011 mobility survey. The ABM results are consistent with previous empirical findings, increasing BRT access does indeed increase the number of minutes that individuals walk for transportation, although this effect also depends on the availability of other transport modes. The model indicates a saturation process: as more BRT lanes are added, the increment in minutes walking becomes smaller, and eventually the walking time decreases. Our findings on the potential contribution of the expansion of the BRT system to walking for transportation suggest that ABMs may prove helpful in designing policies to continue promoting walking. Copyright © 2016 Elsevier Inc. All rights reserved.

  19. A system for applying rapid warming or cooling stimuli to cells during patch clamp recording or ion imaging.

    Science.gov (United States)

    Reid, G; Amuzescu, B; Zech, E; Flonta, M L

    2001-10-15

    We describe a system for superfusing small groups of cells at a precisely controlled and rapidly adjustable local temperature. Before being applied to the cell or cells under study, solutions are heated or cooled in a chamber of small volume ( approximately 150 microl) and large surface area, sandwiched between four small Peltier elements. The current through the Peltier elements is controlled by a microprocessor using a PID (proportional-integral-derivative) feedback algorithm. The chamber can be heated to at least 60 degrees C and cooled to 0 degrees C, changing its temperature at a maximum rate of about 7 degrees C per second; temperature ramps can be followed under feedback control at up to 4 degrees C per second. Temperature commands can be applied from the digital-to-analogue converter of any laboratory interface or generated digitally by the microprocessor. The peak-to-peak noise contributed by the system does not exceed that contributed by a patch pipette, holder and headstage, making it suitable for single channel as well as whole cell recordings.

  20. Prompt Assessment of Global Earthquakes for Response (PAGER): A System for Rapidly Determining the Impact of Earthquakes Worldwide

    Science.gov (United States)

    Earle, Paul S.; Wald, David J.; Jaiswal, Kishor S.; Allen, Trevor I.; Hearne, Michael G.; Marano, Kristin D.; Hotovec, Alicia J.; Fee, Jeremy

    2009-01-01

    Within minutes of a significant earthquake anywhere on the globe, the U.S. Geological Survey (USGS) Prompt Assessment of Global Earthquakes for Response (PAGER) system assesses its potential societal impact. PAGER automatically estimates the number of people exposed to severe ground shaking and the shaking intensity at affected cities. Accompanying maps of the epicentral region show the population distribution and estimated ground-shaking intensity. A regionally specific comment describes the inferred vulnerability of the regional building inventory and, when available, lists recent nearby earthquakes and their effects. PAGER's results are posted on the USGS Earthquake Program Web site (http://earthquake.usgs.gov/), consolidated in a concise one-page report, and sent in near real-time to emergency responders, government agencies, and the media. Both rapid and accurate results are obtained through manual and automatic updates of PAGER's content in the hours following significant earthquakes. These updates incorporate the most recent estimates of earthquake location, magnitude, faulting geometry, and first-hand accounts of shaking. PAGER relies on a rich set of earthquake analysis and assessment tools operated by the USGS and contributing Advanced National Seismic System (ANSS) regional networks. A focused research effort is underway to extend PAGER's near real-time capabilities beyond population exposure to quantitative estimates of fatalities, injuries, and displaced population.

  1. Rapid Development of System-on-Chip (SoC for Network-Enabled Visible Light Communications

    Directory of Open Access Journals (Sweden)

    Trio Adiono

    2018-03-01

    Full Text Available Visible Light Communication (VLC is an emerging optical communication technology with rapid development nowadays. VLC is considered as a compliment and successor of radio-frequency (RF wireless communication. There are various typical implementations of VLC in which one of them is for exchanging data TCP/IP packets, thus the user can browse the internet as in established Wireless fidelity (Wi-Fi technology. Briefly, we can call it by Light fidelity (Li-Fi. This paper described the design and implementation of System-on-Chip (SoC subsystem for Li-Fi application where the implemented SoC consists of hardware (H/W and software (S/W. In the H/W aspect, Physical Layer (PHY is made by using UART communication with Ethernet connection to communicate with Host/Device personal-computer (PC. In the S/W aspect, Xillinux operating system (OS is used. The H/W- as well as S/W-SoC, are realized in FPGA Zybo Zynq-7000 EPP development board. The functional test result shows (without optical channel or Zybo-to-Zybo only that the implemented SoC is working as expected. It is able to exchange TCP/IP packets between two PCs. Moreover, Ethernet connection has bandwidth up to 83.6 Mbps and PHY layer baud rate has bandwidth up to 921600 bps.

  2. Rapid GNSS and Data Communication System Deployments In Chile and Argentina Following the M8.8 Maule Earthquake

    Science.gov (United States)

    Blume, F.; Meertens, C. M.; Brooks, B. A.; Bevis, M. G.; Smalley, R.; Parra, H.; Baez, J.

    2010-12-01

    Because the signal is so big, great earthquakes allow us to make quantum leaps in our understanding of Earth deformation process and material properties. The Maule earthquake, with its occurrence near a large subaerial landmass and the large numbers of instruments available to study it, will surely become one of the most important geophysical events in modern memory. Much of the important signal, however, decays and changes rapidly in the short-term following the event and so a rapid response is necessary. Actually delivering the data from the CGPS response stations, however, represents an intellectual challenge in terms of properly matching the engineering realities with the scientific desiderata. We expect multiple major science advances to come from these data: (1) Understanding earthquake and tsunami-genesis via use of the coseismic displacement field to create the most well-constrained fault slip and tsunami-genesis models. (2) The role of stress loading on both the principal thrust plane and subsidiary planes. (3) The relationship between fault afterslip to the main event as well as to the distribution of aftershocks (4) Study of large aftershocks jointly using conventional seismology and high-rate GPS coseismic displacement seismogram. (5) Rheological behavior of the fault interface. (6) The mechanical response of the bulk earth to large stress perturbations. Within 10 days of the earthquake 20 complete GPS systems were delivered by UNAVCO personnel to IGM and OSU staff in Santiago, and 5 were shipped via diplomatic pouch to Argentina. Consisting of of 10 Trimble NetRS and 15 Topcon GB-1000 receivers, the units were deployed througout the affected area during the following three weeks, using welded-in-place steel tripod monuments driven into soil or drilled into bedrock, or steel masts. Additional GPS hardware was procured from cooperating institutions and donated by GPS manufacturers, and a total of 43 post-earthquake GPS stations are continuously operating

  3. Rapid turn-around mapping of wildfires and disasters with airborne infrared imagery fro the new FireMapper® 2.0 and Oilmapper systems

    Science.gov (United States)

    James W. Hoffman; Lloyd L. Coulter; Philip J Riggan

    2005-01-01

    The new FireMapper® 2.0 and OilMapper airborne, infrared imaging systems operate in a "snapshot" mode. Both systems feature the real time display of single image frames, in any selected spectral band, on a daylight readable tablet PC. These single frames are displayed to the operator with full temperature calibration in color or grayscale renditions. A rapid...

  4. Analysis of changes in water cycle across Northern Eurasia with Rapid Integrated Mapping and Analysis System (RIMS)

    Science.gov (United States)

    Shiklomanov, A.; Prusevich, A.

    2012-04-01

    Historical and contemporary changes in various components of the hydrological cycle across the Northern Eurasia have been investigated using multiple observational and modeled data compiled in Rapid Integrated Mapping and Analysis System (RIMS) for North Eurasian Earth Science Partnership Initiative (NEESPI). To evaluate potential future patterns of change in the Northern Eurasian water cycle we have used climate change projections simulated by several coupled Atmosphere-Ocean General Circulation Models (AO GCMs). Future changes in hydrological regime were assessed using the UNH Water Balance and Water Transport Models (WBM/WTM) which take into account water management including irrigation and reservoir regulation. We found significant shifts in the regional hydrology and quantified potential natural and anthropogenic causes of these changes. The results of our historical and future analysis have demonstrated an intensification of hydrological cycle in many regions of the Northern Eurasia observed over 50-60 year period with accelerated rate during the last decade. Based on climate projections we can expect that the current rate of changes to continue over the course of XXI century. A significant part of the analysis and quantitative estimates of water cycle trends in Northern Eurasia has been done using RIMS online and offline data analysis tools. RIMS has been developed by the Water Systems Analysis Group at the University of New Hampshire, USA for the NEESPI program. Presently, the RIMS data pool is composed of a variety of themes including climate, hydrology, land cover, human dimension, and others. It comprises over five thousand single layer (e.g. soil type) and time series (e.g. daily runoff) raster GIS coverages, and a number of climate and hydrology station/point network datasets. The system streamlines data mining, management and model feeds in the computational environment of large and diverse data holdings. In this presentation we want to demonstrate

  5. Health co-benefits in mortality avoidance from implementation of the mass rapid transit (MRT) system in Kuala Lumpur, Malaysia.

    Science.gov (United States)

    Kwan, Soo Chen; Tainio, Marko; Woodcock, James; Hashim, Jamal Hisham

    2016-03-01

    The mass rapid transit (MRT) is the largest transport infrastructure project under the national key economic area (NKEA) in Malaysia. As urban rail is anticipated to be the future spine of public transport network in the Greater Kuala Lumpur city, it is important to mainstream climate change mitigation and public health benefits in the local transport development. This study quantifies the health co-benefits in terms of mortality among the urbanites when the first line of the 150 km MRT system in Kuala Lumpur commences by 2017. Using comparative health risk assessment, we estimated the potential health co-benefits from the establishment of the MRT system. We estimated the reduced CO2 emissions and air pollution (PM2.5) exposure reduction among the general population from the reduced use of motorized vehicles. Mortality avoided from traffic incidents involving motorcycles and passenger cars, and from increased physical activity from walking while using the MRT system was also estimated. A total of 363,130 tonnes of CO2 emissions could be reduced annually from the modal shift from cars and motorcycles to the MRT system. Atmospheric PM2.5 concentration could be reduced 0.61 μg/m3 annually (2%). This could avoid a total of 12 deaths, mostly from cardio-respiratory diseases among the city residents. For traffic injuries, 37 deaths could be avoided annually from motorcycle and passenger cars accidents especially among the younger age categories (aged 15-30). One additional death was attributed to pedestrian walking. The additional daily physical activity to access the MRT system could avoid 21 deaths among its riders. Most of the mortality avoided comes from cardiovascular diseases. Overall, a total of 70 deaths could be avoided annually among both the general population and the MRT users in the city. The implementation of the MRT system in Greater Kuala Lumpur could bring substantial health co-benefits to both the general population and the MRT users mainly from the

  6. The Heliopause Electrostatic Rapid Transit System (HERTS) - Design, Trades, and Analyses Performed in a Two Year NASA Investigation of Electric Sail Propulsion Systems

    Science.gov (United States)

    Wiegmann, Bruce M.; Scheider, Todd; Heaton, Andrew; Vaughn, Jason; Stone, Nobie; Wright, Ken

    2017-01-01

    Personnel from NASA's MSFC have been investigating the feasibility of an advanced propulsion system known as the Electric Sail (E-Sail) for future scientific exploration missions. This team initially won a NASA Space Technology Mission Directorate (STMD) Phase I NASA Innovative Advanced Concept (NIAC) award and then a two-year follow-on Phase II NIAC award in October 2015. This paper documents the findings from this three-year investigation. An Electric sail, a propellant-less propulsion system, uses solar wind ions to rapidly travel either to deep space or the inner solar system. Scientific spacecraft could reach Pluto in 5 years, or the boundary of the solar system in ten to twelve years compared to the thirty-five plus years the Voyager spacecraft took. The team's recent focuses have been: 1) Developing a Particle in Cell (PIC) numeric engineering model from MSFC's experimental data on the interaction between simulated solar wind and a charged bare wire that can be applied to a variety of missions, 2) Determining what missions could benefit from this revolutionary propulsion system, 3) Conceptualizing spacecraft designs for various tasks: to reach the solar system's edge, to orbit the sun as Heliophysics sentinels, or to examine a multitude of asteroids.

  7. A Prototype Regional GSI-based EnKF-Variational Hybrid Data Assimilation System for the Rapid Refresh Forecasting System: Dual-Resolution Implementation and Testing Results

    Science.gov (United States)

    Pan, Yujie; Xue, Ming; Zhu, Kefeng; Wang, Mingjun

    2018-05-01

    A dual-resolution (DR) version of a regional ensemble Kalman filter (EnKF)-3D ensemble variational (3DEnVar) coupled hybrid data assimilation system is implemented as a prototype for the operational Rapid Refresh forecasting system. The DR 3DEnVar system combines a high-resolution (HR) deterministic background forecast with lower-resolution (LR) EnKF ensemble perturbations used for flow-dependent background error covariance to produce a HR analysis. The computational cost is substantially reduced by running the ensemble forecasts and EnKF analyses at LR. The DR 3DEnVar system is tested with 3-h cycles over a 9-day period using a 40/˜13-km grid spacing combination. The HR forecasts from the DR hybrid analyses are compared with forecasts launched from HR Gridpoint Statistical Interpolation (GSI) 3D variational (3DVar) analyses, and single LR hybrid analyses interpolated to the HR grid. With the DR 3DEnVar system, a 90% weight for the ensemble covariance yields the lowest forecast errors and the DR hybrid system clearly outperforms the HR GSI 3DVar. Humidity and wind forecasts are also better than those launched from interpolated LR hybrid analyses, but the temperature forecasts are slightly worse. The humidity forecasts are improved most. For precipitation forecasts, the DR 3DEnVar always outperforms HR GSI 3DVar. It also outperforms the LR 3DEnVar, except for the initial forecast period and lower thresholds.

  8. A lab-on-a-chip system with integrated sample preparation and loop-mediated isothermal amplification for rapid and quantitative detection of Salmonella spp. in food samples

    DEFF Research Database (Denmark)

    Sun, Yi; Than Linh, Quyen; Hung, Tran Quang

    2015-01-01

    was capable to detect Salmonella at concentration of 50 cells per test within 40 min. The simple design, together with high level of integration, isothermal amplification, and quantitative analysis of multiple samples in short time will greatly enhance the practical applicability of the LOC system for rapid...... amplification (LAMP) for rapid and quantitative detection of Salmonella spp. in food samples. The whole diagnostic procedures including DNA isolation, isothermal amplification, and real-time detection were accomplished in a single chamber. Up to eight samples could be handled simultaneously and the system...... and usually take a few hours to days to complete. In response to the demand for rapid on line or at site detection of pathogens, in this study, we describe for the first time an eight-chamber lab-on-a-chip (LOC) system with integrated magnetic beads-based sample preparation and loop-mediated isothermal...

  9. Effect of Potassium Chlorate on the Treatment of Domestic Sewage by Achieving Shortcut Nitrification in a Constructed Rapid Infiltration System.

    Science.gov (United States)

    Fang, Qinglin; Xu, Wenlai; Yan, Zhijiao; Qian, Lei

    2018-04-04

    A constructed rapid infiltration (CRI) system is a new type of sewage biofilm treatment technology, but due to its anaerobic zone it lacks the carbon sources and the conditions for nitrate retention, and its nitrogen removal performance is very poor. However, a shortcut nitrification–denitrification process presents distinctive advantages, as it saves oxygen, requires less organic matter, and requires less time for denitrification compared to conventional nitrogen removal methods. Thus, if the shortcut nitrification–denitrification process could be applied to the CRI system properly, a simpler, more economic, and efficient nitrogen removal method will be obtained. However, as its reaction process shows that the first and the most important step of achieving shortcut nitrification–denitrification is to achieve shortcut nitrification, in this study we explored the feasibility to achieve shortcut nitrification, which produces nitrite as the dominant nitrogen species in effluent, by the addition of potassium chlorate (KClO₃) to the influent. In an experimental CRI test system, the effects on nitrogen removal, nitrate inhibition, and nitrite accumulation were studied, and the advantages of achieving a shortcut nitrification–denitrification process were also analysed. The results showed that shortcut nitrification was successfully achieved and maintained in a CRI system by adding 5 mM KClO₃ to the influent at a constant pH of 8.4. Under these conditions, the nitrite accumulation percentage was increased, while a lower concentration of 3 mM KClO₃ had no obvious effect. The addition of 5mM KClO₃ in influent presumably inhibited the activity of ammonia-oxidizing bacteria (AOB) and nitrite-oxidizing bacteria (NOB), but inhibition of nitrite-oxidizing bacteria (NOB) was so strong that it resulted in a maximum nitrite accumulation percentage of up to over 80%. As a result, nitrite became the dominant nitrogen product in the effluent. Moreover, if the shortcut

  10. Effect of Potassium Chlorate on the Treatment of Domestic Sewage by Achieving Shortcut Nitrification in a Constructed Rapid Infiltration System

    Directory of Open Access Journals (Sweden)

    Qinglin Fang

    2018-04-01

    Full Text Available A constructed rapid infiltration (CRI system is a new type of sewage biofilm treatment technology, but due to its anaerobic zone it lacks the carbon sources and the conditions for nitrate retention, and its nitrogen removal performance is very poor. However, a shortcut nitrification–denitrification process presents distinctive advantages, as it saves oxygen, requires less organic matter, and requires less time for denitrification compared to conventional nitrogen removal methods. Thus, if the shortcut nitrification–denitrification process could be applied to the CRI system properly, a simpler, more economic, and efficient nitrogen removal method will be obtained. However, as its reaction process shows that the first and the most important step of achieving shortcut nitrification–denitrification is to achieve shortcut nitrification, in this study we explored the feasibility to achieve shortcut nitrification, which produces nitrite as the dominant nitrogen species in effluent, by the addition of potassium chlorate (KClO3 to the influent. In an experimental CRI test system, the effects on nitrogen removal, nitrate inhibition, and nitrite accumulation were studied, and the advantages of achieving a shortcut nitrification–denitrification process were also analysed. The results showed that shortcut nitrification was successfully achieved and maintained in a CRI system by adding 5 mM KClO3 to the influent at a constant pH of 8.4. Under these conditions, the nitrite accumulation percentage was increased, while a lower concentration of 3 mM KClO3 had no obvious effect. The addition of 5mM KClO3 in influent presumably inhibited the activity of ammonia-oxidizing bacteria (AOB and nitrite-oxidizing bacteria (NOB, but inhibition of nitrite-oxidizing bacteria (NOB was so strong that it resulted in a maximum nitrite accumulation percentage of up to over 80%. As a result, nitrite became the dominant nitrogen product in the effluent. Moreover, if the

  11. Thermospheric winds in the auroral oval: observations of small scale structures and rapid fluctuations by a Doppler imaging system

    International Nuclear Information System (INIS)

    Batten, S.; Rees, D.

    1990-01-01

    At high geomagnetic latitudes, thermospheric wind flows are dramatically affected by the combined effects of magnetospheric ion convection and Joule and particle heating. Thermospheric winds have been observed by ground based and space-borne Fabry-Perot interferometers (FPIs). Short period, localized wind fluctuations have always been difficult to resolve with a conventional FPI, due to the limited time and spatial resolution. However, the highest quality wind data obtained by these instruments from the middle and upper thermosphere have implied that thermospheric winds may respond to the combination of strong local ion drag forcing and heating within the auroral oval and polar cap, with spatial scale sizes of 50-500 km, and with time scales as short as 10-30 min. Since the 1982/1983 winter, a prototype Doppler Imaging System (DIS) has been operated at Kiruna (67.84 0 N, 20.42 0 E). This instrument maps thermospheric wind flows over a region some 500 km in diameter centred on Kiruna and has observed many interesting features in the thermospheric wind fields. In particular, strong local wind gradients, rapid wind reversals and small scale structures are regularly observed, particularly during geomagnetically disturbed nights. (author)

  12. A low viscosity, low boiling point, clean solvent system for the rapid crystallisation of highly specular perovskite films

    Energy Technology Data Exchange (ETDEWEB)

    Noel, Nakita K.; Habisreutinger, Severin N.; Wenger, Bernard; Klug, Matthew T.; Hörantner, Maximilian T.; Johnston, Michael B.; Nicholas, Robin J.; Moore, David T.; Snaith, Henry J.

    2017-01-01

    Perovskite-based photovoltaics have, in recent years, become poised to revolutionise the solar industry. While there have been many approaches taken to the deposition of this material, one-step spin-coating remains the simplest and most widely used method in research laboratories. Although spin-coating is not recognised as the ideal manufacturing methodology, it represents a starting point from which more scalable deposition methods, such as slot-dye coating or ink-jet printing can be developed. Here, we introduce a new, low-boiling point, low viscosity solvent system that enables rapid, room temperature crystallisation of methylammonium lead triiodide perovskite films, without the use of strongly coordinating aprotic solvents. Through the use of this solvent, we produce dense, pinhole free films with uniform coverage, high specularity, and enhanced optoelectronic properties. We fabricate devices and achieve stabilised power conversion efficiencies of over 18% for films which have been annealed at 100 degrees C, and over 17% for films which have been dried under vacuum and have undergone no thermal processing. This deposition technique allows uniform coating on substrate areas of up to 125 cm2, showing tremendous promise for the fabrication of large area, high efficiency, solution processed devices, and represents a critical step towards industrial upscaling and large area printing of perovskite solar cells.

  13. Specialists meeting on design and assessment of instrumentation and control systems in NPP coping with rapid technological change

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-10-01

    A transition from analogue to computer based I and C (instrumentation and control) systems in nuclear power plants enabled the industry not only to make use of advantages of computers for the control of technological processes, but also transferred the unusual short innovation cycles in computer technology to become a constraint on the process I and C. This situation led the IAEA to provide an international forum for the presentation and discussion of the problems and organize a Specialists` Meeting in the framework of the International Working Group on Nuclear Power Plant Control and Instrumentation. The basic objective was to elaborate the management, engineering and economic problems arising from rapid technological changes, to point out solutions and to discuss the future trends in the field. The Year 2000 Issue was also inside the scope of the Meeting. Typical problems were technology changes provoking major I and C concept changes, spare part availability, compatibility in refurbishment processes. The present document contains the papers presented by national delegates, each with an abstract, and the conclusions drawn from the final discussion Refs, figs, tabs

  14. Specialists meeting on design and assessment of instrumentation and control systems in NPP coping with rapid technological change

    International Nuclear Information System (INIS)

    1998-10-01

    A transition from analogue to computer based I and C (instrumentation and control) systems in nuclear power plants enabled the industry not only to make use of advantages of computers for the control of technological processes, but also transferred the unusual short innovation cycles in computer technology to become a constraint on the process I and C. This situation led the IAEA to provide an international forum for the presentation and discussion of the problems and organize a Specialists' Meeting in the framework of the International Working Group on Nuclear Power Plant Control and Instrumentation. The basic objective was to elaborate the management, engineering and economic problems arising from rapid technological changes, to point out solutions and to discuss the future trends in the field. The Year 2000 Issue was also inside the scope of the Meeting. Typical problems were technology changes provoking major I and C concept changes, spare part availability, compatibility in refurbishment processes. The present document contains the papers presented by national delegates, each with an abstract, and the conclusions drawn from the final discussion

  15. An evaluation of the Oxoid Biochemical Identification System Campy rapid screening test for Campylobacteraceae and Helicobacter spp.

    Science.gov (United States)

    Hoosain, N; Lastovica, A J

    2009-06-01

    To evaluate the Oxoid Biochemical Identification System (OBIS) Campy test (ID0800M) against Campylobacter; Arcobacter; and other micro-organisms, with similar colonial morphology, for the detection of l-alanine aminopeptidase (l-ALA). The KOH and l-ALA (OBIS and Fluka) tests were carried out on every isolate. The procedures were followed as indicated in the OBIS and Fluka kit instructions. A total of 146 strains of 19 species of Campylobacter, seven strains of Arcobacter butzleri, four Arcobacter butzleri-like strains, 42 strains of 10 species of Helicobacter, 96 Gram-negative and 49 Gram-positive clinical isolates were tested. As expected, Campylobacter and Arcobacter strains were negative, while other Gram-negative bacteria were positive for the l-ALA test. An unexpected finding was that Helicobacter strains, although Gram-negative, were all negative for the l-ALA tests suggesting the absence of l-ALA within this genus. This is a novel finding. The absence of l-ALA was confirmed upon comparison with the available full genomic sequences of Helicobacter on the NCBI database. The OBIS Campy (ID0800M) test kit proved to be rapid and accurate for the presumptive characterization of Campylobacter and Arcobacter. A novel finding was that Helicobacter species also did not have the l-ALA enzyme. The OBIS kit will be useful in diagnostic laboratories for the presumptive diagnosis of Campylobacter, Arcobacter and Helicobacter strains.

  16. Application of a regularized model inversion system (REGFLEC) to multi-temporal RapidEye imagery for retrieving vegetation characteristics

    KAUST Repository

    Houborg, Rasmus

    2015-10-14

    Accurate retrieval of canopy biophysical and leaf biochemical constituents from space observations is critical to diagnosing the functioning and condition of vegetation canopies across spatio-temporal scales. Retrieved vegetation characteristics may serve as important inputs to precision farming applications and as constraints in spatially and temporally distributed model simulations of water and carbon exchange processes. However significant challenges remain in the translation of composite remote sensing signals into useful biochemical, physiological or structural quantities and treatment of confounding factors in spectrum-trait relations. Bands in the red-edge spectrum have particular potential for improving the robustness of retrieved vegetation properties. The development of observationally based vegetation retrieval capacities, effectively constrained by the enhanced information content afforded by bands in the red-edge, is a needed investment towards optimizing the benefit of current and future satellite sensor systems. In this study, a REGularized canopy reFLECtance model (REGFLEC) for joint leaf chlorophyll (Chll) and leaf area index (LAI) retrieval is extended to sensor systems with a band in the red-edge region for the first time. Application to time-series of 5 m resolution multi-spectral RapidEye data is demonstrated over an irrigated agricultural region in central Saudi Arabia, showcasing the value of satellite-derived crop information at this fine scale for precision management. Validation against in-situ measurements in fields of alfalfa, Rhodes grass, carrot and maize indicate improved accuracy of retrieved vegetation properties when exploiting red-edge information in the model inversion process. © (2015) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE).

  17. Rapid immuno-analytical system physically integrated with lens-free CMOS image sensor for food-borne pathogens.

    Science.gov (United States)

    Jeon, Jin-Woo; Kim, Jee-Hyun; Lee, Jong-Mook; Lee, Won-Ho; Lee, Do-Young; Paek, Se-Hwan

    2014-02-15

    To realize an inexpensive, pocket-sized immunosensor system, a rapid test devise based on cross-flow immuno-chromatography was physically combined with a lens-free CMOS image sensor (CIS), which was then applied to the detection of the food-borne pathogen, Salmonella typhimurium (S. typhimurium). Two CISs, each retaining 1.3 mega pixel array, were mounted on a printed circuit board to fabricate a disposable sensing module, being connectable with a signal detection system. For the bacterial analysis, a cellulose membrane-based immunosensing platform, ELISA-on-a-chip (EOC), was employed, being integrated with the CIS module, and the antigen-antibody reaction sites were aligned with the respective sensor. In such sensor construction, the chemiluminescent signals produced from the EOC are transferred directly into the sensors and are converted to electric signals on the detector. The EOC-CIS integrated sensor was capable of detecting a traceable amount of the bacterium (4.22 × 10(3)CFU/mL), nearly comparable to that adopting a sophisticated detector such as cooled-charge-coupled device, while having greatly reduced dimensions and cost. Upon coupling with immuno-magnetic separation, the sensor showed an additional 67-fold enhancement in the detection limit. Furthermore, a real sample test was carried out for fish muscles inoculated with a sample of 3.3CFU S. typhimurium per 10 g, which was able to be detected earlier than 6h after the onset of pre-enrichment by culture. © 2013 Elsevier B.V. All rights reserved.

  18. Culture-Independent Techniques for Rapid Detection of Bacteria Associated with Loss of Chloramine Residual in a Drinking Water System

    Science.gov (United States)

    Hoefel, Daniel; Monis, Paul T.; Grooby, Warwick L.; Andrews, Stuart; Saint, Christopher P.

    2005-01-01

    Chloramination is often the disinfection regimen of choice for extended drinking water systems. However, this process is prone to instability due to the growth of nitrifying bacteria. This is the first study to use alternative approaches for rapid investigation of chloraminated drinking water system instability in which flow cytometric cell sorting of bacteria with intact membranes (membrane-intact fraction) (BacLight kit) or with active esterases (esterase-active fraction) (carboxyfluorescein diacetate) was combined with 16S rRNA gene-directed PCR and denaturing gradient gel electrophoresis (DGGE). No active bacteria were detected when water left the water treatment plant (WTP), but 12 km downstream the chloramine residual had diminished and the level of active bacteria in the bulk water had increased to more than 1 × 105 bacteria ml−1. The bacterial diversity in the system was represented by six major DGGE bands for the membrane-intact fraction and 10 major DGGE bands for the esterase-active fraction. PCR targeting of the 16S rRNA gene of chemolithotrophic ammonia-oxidizing bacteria (AOB) and subsequent DGGE and DNA sequence analysis revealed the presence of an active Nitrosospira-related species and Nitrosomonas cryotolerans in the system, but no AOB were detected in the associated WTP. The abundance of active AOB was then determined by quantitative real-time PCR (qPCR) targeting the amoA gene; 3.43 × 103 active AOB ml−1 were detected in the membrane-intact fraction, and 1.40 × 104 active AOB ml−1 were detected in the esterase-active fraction. These values were several orders of magnitude greater than the 2.5 AOB ml−1 detected using a routine liquid most-probable-number assay. Culture-independent techniques described here, in combination with existing chemical indicators, should allow the water industry to obtain more comprehensive data with which to make informed decisions regarding remedial action that may be required either prior to or during an

  19. The Heliopause Electrostatic Rapid Transit System (HERTS) Design, Trades, and Analyses Performed in a Two Year NASA Investigation of Electric Sail Propulsion Systems

    Science.gov (United States)

    Wiegmann, Bruce M.

    2017-01-01

    The Heliopause Electrostatic Rapid Transit System (HERTS) was one of the seven total Phase II NASA Innovative Advanced Concepts (NIAC) that was down-selected in 2015 for continued funding and research. In Phase I our team learned that a spacecraft propelled by an Electric Sail (E-Sail) can travel great astronomical distances, such as to the Heliopause region of the solar system (approx. 100 to 120 AU) in approximately one quarter of the time (10 years) versus the time it took the Voyager spacecraft launched in 1977 (36 years). The completed work within the Phase II NIAC funded effort builds upon the work that was done in the Phase I NIAC and is focused on: 1) Testing of plasma interaction with a charged wire in a MSFC simulated solar environment vacuum test chamber. 2) Development of a Particle-in-Cell (PIC) models that are validated in the plasma testing and used to extrapolate to the E-Sail propulsion system design. 3) Conceptual design of a Technology Demonstration Mission (TDM) spacecraft developed to showcase E-Sail propulsion systems. 4) Down selection of both: a) Materials for a multi km length conductor and, b) Best configuration of the proposed conductor deployment subsystem. This paper will document the findings to date (June, 2017) of the above focused areas.

  20. Rapid world modeling

    International Nuclear Information System (INIS)

    Little, Charles; Jensen, Ken

    2002-01-01

    Sandia National Laboratories has designed and developed systems capable of large-scale, three-dimensional mapping of unstructured environments in near real time. This mapping technique is called rapid world modeling and has proven invaluable when used by prototype systems consisting of sensory detection devices mounted on mobile platforms. These systems can be deployed into previously unmapped environments and transmit real-time 3-D visual images to operators located remotely. This paper covers a brief history of the rapid world modeling system, its implementation on mobile platforms, and the current state of the technology. Applications to the nuclear power industry are discussed. (author)

  1. Protection Conferred by recombinant Yersinia pestis Antigens Produced by a Rapid and Highly Scalable Plant Expression System

    National Research Council Canada - National Science Library

    Santi, Luca; Giritch, Anatoli; Roy, Chad J; Marillonnet, Sylvestre; Klimyuk, Victor; Gleba, Yuri; Webb, Robert; Arntzen, Charles J; Mason, Hugh S

    2006-01-01

    ... have highlighted the need for a safe, efficacious, and rapidly producible vaccine. The use of F1 and V antigens and the derived protein fusion F1-V has shown great potential as a protective vaccine in animal studies...

  2. Rapid construction of pinhole SPECT system matrices by distance-weighted Gaussian interpolation method combined with geometric parameter estimations

    International Nuclear Information System (INIS)

    Lee, Ming-Wei; Chen, Yi-Chun

    2014-01-01

    In pinhole SPECT applied to small-animal studies, it is essential to have an accurate imaging system matrix, called H matrix, for high-spatial-resolution image reconstructions. Generally, an H matrix can be obtained by various methods, such as measurements, simulations or some combinations of both methods. In this study, a distance-weighted Gaussian interpolation method combined with geometric parameter estimations (DW-GIMGPE) is proposed. It utilizes a simplified grid-scan experiment on selected voxels and parameterizes the measured point response functions (PRFs) into 2D Gaussians. The PRFs of missing voxels are interpolated by the relations between the Gaussian coefficients and the geometric parameters of the imaging system with distance-weighting factors. The weighting factors are related to the projected centroids of voxels on the detector plane. A full H matrix is constructed by combining the measured and interpolated PRFs of all voxels. The PRFs estimated by DW-GIMGPE showed similar profiles as the measured PRFs. OSEM reconstructed images of a hot-rod phantom and normal rat myocardium demonstrated the effectiveness of the proposed method. The detectability of a SKE/BKE task on a synthetic spherical test object verified that the constructed H matrix provided comparable detectability to that of the H matrix acquired by a full 3D grid-scan experiment. The reduction in the acquisition time of a full 1.0-mm grid H matrix was about 15.2 and 62.2 times with the simplified grid pattern on 2.0-mm and 4.0-mm grid, respectively. A finer-grid H matrix down to 0.5-mm spacing interpolated by the proposed method would shorten the acquisition time by 8 times, additionally. -- Highlights: • A rapid interpolation method of system matrices (H) is proposed, named DW-GIMGPE. • Reduce H acquisition time by 15.2× with simplified grid scan and 2× interpolation. • Reconstructions of a hot-rod phantom with measured and DW-GIMGPE H were similar. • The imaging study of normal

  3. A Functional Thinking Approach to the Design of Future Transportation Systems: Taxis as a Proxy for Personal Rapid Transit in South Korea

    DEFF Research Database (Denmark)

    Thompson, Mary Kathryn; Bae, Hyun Hye

    2014-01-01

    For over 50 years, personal rapid transit (PRT) has been viewed as one of the most promising ways to provide sustainable, economical, and convenient transportation while reducing reliance on personal automobiles. However, despite concerted efforts around the world, the promise of PRT has yet...... to be realized. This work demonstrates that different physical means, such as the Korean taxi system, can be used to perform the same highest-level functional requirement, satisfy the same constraints, and provide many of the benefits that are expected of a city-scale personal rapid transit system. Thus, Korean...... taxis can be used as an alternative embodiment of personal rapid transit and can serve as a test bed to support PRT-related design, research, and development. The paper then explores the transportation patterns and characteristics of cities in South Korea and the United States in order to determine...

  4. Development of a system for rapid discharge of spherical fuel elements as a diversitary afterheat removal system for pebble-bed HTR-type reactors

    International Nuclear Information System (INIS)

    Phlippen, P.W.

    1982-07-01

    Owing to its spherical fuel elements the pebble bed high temperature reactor provides the possibility to remove these fuel elements rapidly from the reactor for the purpose of after-heat removal and cooling in situations of danger and to collect them in easily cooled tanks. The paper investigates and represents fields of problems such as critically behaviour of core and fuel element collecting tanks, emission time of the core, thermodynamics in the vessel etc. by example of the PNP-500 reactor concept. A selection for the construction proposal was made from the performance possibilities of the three necessary main components prestressed-concrete vessel closure, fuel element guide and fuel element storage with cooling system. The proposal includes a prestressed concrete vessel closure opening by hydraulics as well as three annular fuel element storage modules cooled with the containment air by natural convection. (orig.) [de

  5. Catastrophic shifts in vegetation-soil systems may unfold rapidly or slowly independent of the rate of change in the system driver

    Science.gov (United States)

    Karssenberg, Derek; Bierkens, Marc

    2014-05-01

    Complex systems may switch between contrasting stable states under gradual change of a driver. Such critical transitions often result in considerable long-term damage because strong hysteresis impedes reversion, and the transition becomes catastrophic. Critical transitions largely reduce our capability of forecasting future system states because it is hard to predict the timing of their occurrence [2]. Moreover, for many systems it is unknown how rapidly the critical transition unfolds when the tipping point has been reached. The rate of change during collapse, however, is important information because it determines the time available to take action to reverse a shift [1]. In this study we explore the rate of change during the degradation of a vegetation-soil system on a hillslope from a state with considerable vegetation cover and large soil depths, to a state with sparse vegetation and a bare rock or negligible soil depths. Using a distributed, stochastic model coupling hydrology, vegetation, weathering and water erosion, we derive two differential equations describing the vegetation and the soil system, and their interaction. Two stable states - vegetated and bare - are identified by means of analytical investigation, and it is shown that the change between these two states is a critical transition as indicated by hysteresis. Surprisingly, when the tipping point is reached under a very slow increase of grazing pressure, the transition between the vegetated and the bare state can either unfold rapidly, over a few years, or gradually, occurring over decennia up to millennia. These differences in the rate of change during the transient state are explained by differences in bedrock weathering rates. This finding emphasizes the considerable uncertainty associated with forecasting catastrophic shifts in ecosystems, which is due to both difficulties in forecasting the timing of the tipping point and the rate of change when the transition unfolds. References [1] Hughes

  6. Development of a triple hyphenated HPLC-radical scavenging detection-DAD-SPE-NMR system for the rapid identification of antioxidants in complex plant extracts

    NARCIS (Netherlands)

    Pukalskas, A.; Beek, van T.A.; Waard, de P.

    2005-01-01

    A rapid method for the simultaneous detection and identification of radical scavenging compounds in plant extracts was developed by combining an HPLC with on-line radical scavenging using DPPH as a model radical and an HPLC¿DAD¿SPE¿NMR system. Using this method a commercial rosemary extract was

  7. A rapid screening method to monitor expression of various recombinant proteins from prokaryotic and eukaryotic expression systems using MALDI-TOF mass spectrometry

    DEFF Research Database (Denmark)

    Jebanathirajah, J.A.; Andersen, S.; Blagoev, B.

    2002-01-01

    Rapid methods using matrix-assisted laser desorption ionization-time-of-flight mass spectrometry to monitor recombinant protein expression from various prokaryotic and eukaryotic cell culture systems were devised. Intracellular as well as secreted proteins from both induced and constitutive...

  8. Portable wireless neurofeedback system of EEG alpha rhythm enhances memory.

    Science.gov (United States)

    Wei, Ting-Ying; Chang, Da-Wei; Liu, You-De; Liu, Chen-Wei; Young, Chung-Ping; Liang, Sheng-Fu; Shaw, Fu-Zen

    2017-11-13

    Effect of neurofeedback training (NFT) on enhancement of cognitive function or amelioration of clinical symptoms is inconclusive. The trainability of brain rhythm using a neurofeedback system is uncertainty because various experimental designs are used in previous studies. The current study aimed to develop a portable wireless NFT system for alpha rhythm and to validate effect of the NFT system on memory with a sham-controlled group. The proposed system contained an EEG signal analysis device and a smartphone with wireless Bluetooth low-energy technology. Instantaneous 1-s EEG power and contiguous 5-min EEG power throughout the training were developed as feedback information. The training performance and its progression were kept to boost usability of our device. Participants were blinded and randomly assigned into either the control group receiving random 4-Hz power or Alpha group receiving 8-12-Hz power. Working memory and episodic memory were assessed by the backward digital span task and word-pair task, respectively. The portable neurofeedback system had advantages of a tiny size and long-term recording and demonstrated trainability of alpha rhythm in terms of significant increase of power and duration of 8-12 Hz. Moreover, accuracies of the backward digital span task and word-pair task showed significant enhancement in the Alpha group after training compared to the control group. Our tiny portable device demonstrated success trainability of alpha rhythm and enhanced two kinds of memories. The present study suggest that the portable neurofeedback system provides an alternative intervention for memory enhancement.

  9. Rapid improvement teams.

    Science.gov (United States)

    Alemi, F; Moore, S; Headrick, L; Neuhauser, D; Hekelman, F; Kizys, N

    1998-03-01

    Suggestions, most of which are supported by empirical studies, are provided on how total quality management (TQM) teams can be used to bring about faster organizationwide improvements. Ideas are offered on how to identify the right problem, have rapid meetings, plan rapidly, collect data rapidly, and make rapid whole-system changes. Suggestions for identifying the right problem include (1) postpone benchmarking when problems are obvious, (2) define the problem in terms of customer experience so as not to blame employees nor embed a solution in the problem statement, (3) communicate with the rest of the organization from the start, (4) state the problem from different perspectives, and (5) break large problems into smaller units. Suggestions for having rapid meetings include (1) choose a nonparticipating facilitator to expedite meetings, (2) meet with each team member before the team meeting, (3) postpone evaluation of ideas, and (4) rethink conclusions of a meeting before acting on them. Suggestions for rapid planning include reducing time spent on flowcharting by focusing on the future, not the present. Suggestions for rapid data collection include (1) sample patients for surveys, (2) rely on numerical estimates by process owners, and (3) plan for rapid data collection. Suggestions for rapid organizationwide implementation include (1) change membership on cross-functional teams, (2) get outside perspectives, (3) use unfolding storyboards, and (4) go beyond self-interest to motivate lasting change in the organization. Additional empirical investigations of time saved as a consequence of the strategies provided are needed. If organizations solve their problems rapidly, fewer unresolved problems may remain.

  10. Diversity, Community Composition, and Dynamics of Nonpigmented and Late-Pigmenting Rapidly Growing Mycobacteria in an Urban Tap Water Production and Distribution System

    OpenAIRE

    Dubrou, S.; Konjek, J.; Macheras, E.; Welté, B.; Guidicelli, L.; Chignon, E.; Joyeux, M.; Gaillard, J. L.; Heym, B.; Tully, T.; Sapriel, G.

    2013-01-01

    Nonpigmented and late-pigmenting rapidly growing mycobacteria (RGM) have been reported to commonly colonize water production and distribution systems. However, there is little information about the nature and distribution of RGM species within the different parts of such complex networks or about their clustering into specific RGM species communities. We conducted a large-scale survey between 2007 and 2009 in the Parisian urban tap water production and distribution system. We analyzed 1,418 w...

  11. [Digital imaging system are rapidly introduced in Swedish departments of radiography. This calls for new strategic planning].

    Science.gov (United States)

    Laurin, S; Norberg, K A

    2000-10-11

    Diagnostic radiology in Sweden is changing rapidly to digital (filmless) technique. The advantages are more rapid delivery of radiologic service, better working conditions and less negative effects on the environment. Teleradiology is also facilitated. The Swedish Board of Health and Welfare has investigated the speed with which this change is taking place. In 1998, 26 of the 118 departments of diagnostic radiology had already turned digital; it is estimated that in the near future at least five departments will become fully digital each year. For planning purposes, less emphasis should be put on the supply of radiographic film, and more on telecommunications, computer hardware and digital storage.

  12. Application of a regularized model inversion system (REGFLEC) to multi-temporal RapidEye imagery for retrieving vegetation characteristics

    KAUST Repository

    Houborg, Rasmus; McCabe, Matthew

    2015-01-01

    to time-series of 5 m resolution multi-spectral RapidEye data is demonstrated over an irrigated agricultural region in central Saudi Arabia, showcasing the value of satellite-derived crop information at this fine scale for precision management. Validation

  13. Assessing health systems for type 1 diabetes in sub-Saharan Africa: developing a 'Rapid Assessment Protocol for Insulin Access'

    DEFF Research Database (Denmark)

    Beran, David; Yudkin, John S; de Courten, Maximilian

    2006-01-01

    In order to improve the health of people with Type 1 diabetes in developing countries, a clear analysis of the constraints to insulin access and diabetes care is needed. We developed a Rapid Assessment Protocol for Insulin Access, comprising a series of questionnaires as well as a protocol...... for the gathering of other data through site visits, discussions, and document reviews....

  14. Development of a rapid and simple Agrobacterium tumefaciens mediated transformation system for the fungal pathogen Heterobasidion annosum

    Science.gov (United States)

    Nicklas Samils; Malin Elfstrand; Daniel L. Lindner Czederpiltz; Jan Fahleson; Ake Olson; Christina Dixelius; Jan Stenlid

    2006-01-01

    Heterobasidion annosum causes root and butt-rot in trees and is the most serious forest pathogen in the northern hemisphere. We developed a rapid and simple Agrobacterium-mediated method of gene delivery into H. annosum to be used in functional studies of candidate genes and for visualization of mycelial interactions. Heterobasidion annosum TC 32-1 was cocultivated at...

  15. A rapid appraisal process on an irrigation system in Pakistan; Evaluacion rapida de una zona de riego tipica de Pakistan

    Energy Technology Data Exchange (ETDEWEB)

    Ruiz-Carmona, Victor Manuel; Ojeda-Bustamante, Waldo [Instituto Mexicano de Tecnologia del Agua, Jiutepec, Morelos (Mexico); Contijoch, Manuel [Banco Mundial (Mexico)

    2006-07-15

    This paper presents the results obtained on the implementation of a rapid appraisal process on an irrigation system in the province of Punjab in Pakistan. The purpose of the evaluation was to know the present irrigation service quality and to propose some alternative to improve it. The evaluation results were: the canal inflow is smaller than peak crop water requirement; net aquifer loss; crops are always under stress which is reflected on low crop yields, the secondary canal network has not control structures and was not designed for rotation, insufficient human-human communication between canal operators; the operators have no complementary training course to enhance their capacity; discrepancy between the service the canal is supposed to provide and the real service it offers. The suggested actions to improve the irrigation service were: the irrigation service must be client oriented; the irrigation users should participate to determine the irrigation service characteristics; the difference between actual and stage irrigation service must be eliminated; clear definition on water allocation; implement a modernization program to provide the irrigation service required. The evaluation methodology used can be applied in other countries like Mexico for the analysis of large irrigation systems making an optimal use of time and resources. [Spanish] En el presente trabajo se muestran los resultados obtenidos al aplicar una metodologia de evaluacion rapida de sistemas de riego a una zona de la provincia del Punjab, Pakistan. El objetivo de la evaluacion fue conocer el estado actual del servicio de riego que ofrece la agencia responsable del manejo del riego en un distrito del Punjab y proponer alternativas para mejorarlo. Los principales resultados de esta evaluacion fueron los siguientes: la falta de capacidad de los canales, el abatimiento neto del acuifero; el estres hidrico continuo de los cultivos, que propicia un bajo rendimiento; la red secundaria de canales no

  16. A simple and rapid approach to develop recombinant avian herpesvirus vectored vaccines using CRISPR/Cas9 system.

    Science.gov (United States)

    Tang, Na; Zhang, Yaoyao; Pedrera, Miriam; Chang, Pengxiang; Baigent, Susan; Moffat, Katy; Shen, Zhiqiang; Nair, Venugopal; Yao, Yongxiu

    2018-01-29

    Herpesvirus of turkeys (HVT) has been successfully used as live vaccine against Marek's disease (MD) worldwide for more than 40 years either alone or in combination with other serotypes. HVT is also widely used as a vector platform for generation of recombinant vaccines against a number of avian diseases such as infectious bursal disease (IBD), Newcastle disease (ND) and avian influenza (AI) using conventional recombination methods or recombineering tools on cloned viral genomes. In the present study, we describe the application of CRISPR/Cas9-based genome editing as a rapid and efficient method of generating HVT recombinants expressing VP2 protein of IBDV. This approach offers an efficient method to introduce other viral antigens into the HVT genome for rapid development of recombinant vaccines. Copyright © 2018 The Pirbright Institute. Published by Elsevier Ltd.. All rights reserved.

  17. Rapid Open Source GPS software development for modern embedded systems:using the GPSTk with the Gumstix

    OpenAIRE

    Salazar Hernández, Dagoberto José; Hernández Pajares, Manuel; Juan Zornoza, José Miguel; Sanz Subirana, Jaume

    2006-01-01

    This work shows how the combination of GPS Open Source Software (GOSS) and advanced full function miniature computers (FFMC) allows rapid development, implementation and testing of advanced embedded GNSS data processing applications in a flexible way. In this regard, our tools of choice are the “GPS Toolkit” (GPSTk), and a modern, high power embedded platform such as the “Gumstix” computer boards. Peer Reviewed

  18. Center of mass energy and system-size dependence of photon production at forward rapidity at RHIC

    Czech Academy of Sciences Publication Activity Database

    Abelev, B. I.; Aggarwal, M. M.; Ahammed, Z.; Alakhverdyants, A. V.; Anderson, B.D.; Arkhipkin, D.; Averichev, G. S.; Badyal, S. K.; Balewski, J.; Barannikova, O.; Barnby, L. S.; Baudot, J.; Baumgart, S.; Beavis, D.R.; Bellwied, R.; Benedosso, F.; Betancourt, M.J.; Betts, R. R.; Bhasin, A.; Bhati, A.K.; Bichsel, H.; Bielčík, Jaroslav; Bielčíková, Jana; Biritz, B.; Bland, L.C.; Bnzarov, I.; Bombara, M.; Bonner, B.E.; Bouchet, J.; Braidot, E.; Brandin, A.V.; Bruna, E.; Bueltmann, S.; Burton, T.P.; Bysterský, Michal; Cai, X.Z.; Caines, H.; Calderon, M.; Catu, O.; Cebra, D.; Cendejas, R.; Cervantes, M.C.; Chajecki, Z.; Chaloupka, Petr; Chattopadhyay, S.; Chen, H.F.; Chen, J.H.; Chen, J.Y.; Cheng, J.; Cherney, M.; Chikanian, A.; Choi, K.E.; Christie, W.; Clarke, R.F.; Codrington, M.J.M.; Corliss, R.; Cormier, T.M.; Cosentino, M.R.; Cramer, J. G.; Crawford, H. J.; Das, D.; Das, S.; Dash, S.; Daugherity, M.; De Silva, L.C.; Dedovich, T. G.; DePhillips, M.; Derevschikov, A.A.; de Souza, R.D.; Didenko, L.; Djawotho, P.; Dogra, S.M.; Dong, X.; Drachenberg, J.L.; Draper, J. E.; Dunlop, J.C.; Mazumdar, M.R.D.; Efimov, L.G.; Elhalhuli, E.; Elnimr, M.; Engelage, J.; Eppley, G.; Erazmus, B.; Estienne, M.; Eun, L. (ed.); Fachini, P.; Fatemi, R.; Fedorisin, J.; Feng, A.; Filip, P.; Finch, E.; Fine, V.; Fisyak, Y.; Gagliardi, C. A.; Gaillard, L.; Gangaharan, D.R.; Ganti, M.S.; Garcia-Solis, E.J.; Geromitsos, A.; Geurts, F.; Ghazikhanian, V.; Ghosh, P.; Gorbunov, Y.N.; Gordon, A.; Grebenyuk, O.; Grosnick, D.; Grube, B.; Guertin, S.M.; Guimaraes, K.S.F.F.; Gupta, A.; Gupta, N.; Guryn, W.; Haag, B.; Hallman, T.J.; Hamed, A.; Harris, J.W.; He, W.; Heinz, M.; Hepplemann, S.; Hippolyte, B.; Hirsch, A.; Hjort, E.; Hoffman, A.M.; Hoffmann, G.W.; Hofman, D.J.; Hollis, R.S.; Huang, H.Z.; Humanic, T.J.; Huo, L.; Igo, G.; Lordanova, A.; Jacobs, P.; Jacobs, W.W.; Jakl, Pavel; Jena, C.; Jin, F.; Jones, C.L.; Jones, P.G.; Joseph, J.; Judd, E.G.; Kabana, S.; Kajimoto, K.; Kang, K.; Kapitán, Jan; Kauder, K.; Keane, D.; Kechechyan, A.; Kettler, D.; Khodyrev, V.Yu.; Kikola, D.P.; Kiryluk, J.; Kisiel, A.; Klein, S.R.; Knospe, A.G.; Kocoloski, A.; Koetke, D.D.; Konzer, J.; Kopytine, M.; Koralt, I.; Korsch, W.; Kotchenda, L.; Kushpil, Vasilij; Kravtsov, P.; Kravtsov, V.I.; Krueger, K.; Krus, M.; Kuhn, C.; Kumar, L.; Kurnadi, P.; Lamont, M.A.C.; Landgraf, J.M.; LaPointe, S.; Lauret, J.; Lebedev, A.; Lednický, Richard; Lee, Ch.; Lee, J.H.; Leight, W.; LeVine, M.J.; Li, C.; Li, N.; Li, Y.; Lin, G.; Lindenbaum, S.J.; Lisa, M.A.; Liu, F.; Liu, H.; Liu, J.; Liu, L.; Ljubicic, T.; Llope, W.J.; Longacre, R.S.; Love, W.A.; Lu, Y.; Ludlam, T.; Ma, G.L.; Ma, Y.G.; Mahapatra, D.P.; Majka, R.; Mall, O.I.; Mangotra, L.K.; Manweiler, R.; Margetis, S.; Markert, C.; Masui, H.; Matis, H.S.; Matulenko, Yu.A.; McDonald, D.; McShane, T.S.; Meschanin, A.; Millner, R.; Minaev, N.G.; Mioduszewski, S.; Mischke, A.; Mohanty, B.; Mondal, M.M.; Morozov, D.A.; Munhoz, M. G.; Nandi, B.K.; Nattrass, C.; Nayak, T. K.; Nelson, J.M.; Netrakanti, P.K.; Ng, M.J.; Nogach, L.V.; Nurushev, S.B.; Odyniec, G.; Ogawa, A.; Okada, H.; Okorokov, V.; Olson, D.; Pachr, M.; Page, B.S.; Pal, S.K.; Pandit, Y.; Panebratsev, Y.; Pawlak, T.; Peitzmann, T.; Perevoztchikov, V.; Perkins, C.; Peryt, W.; Phatak, S.C.; Pile, P.; Planinic, M.; Ploskon, M.A.; Pluta, J.; Plyku, D.; Poljak, N.; Poskanzer, A.M.; Potukuchi, B.V.K.S.; Prindle, D.; Pruneau, C.; Pruthi, N.K.; Pujahari, P.R.; Putschke, J.; Raniwala, R.; Raniwala, S.; Ray, R.L.; Redwine, R.; Reed, R.; Ridiger, A.; Ritter, H.G.; Roberts, J.B.; Rogachevskiy, O.V.; Romero, J.L.; Rose, A.; Roy, C.; Ruan, L.; Russcher, M.J.; Sahoo, R.; Sakai, S.; Sakrejda, I.; Sakuma, T.; Salur, S.; Sandweiss, J.; Sarsour, M.; Schambach, J.; Scharenberg, R.P.; Schmitz, N.; Seger, J.; Selyuzhenkov, I.; Seyboth, P.; Shabetai, A.; Shahaliev, E.; Shao, M.; Sharma, M.; Shi, S.S.; Shi, X.H.; Sichtermann, E.P.; Simon, F.; Singaraju, R.N.; Skoby, M.J.; Smirnov, N.; Sorensen, P.; Sowinski, J.; Spinka, H.M.; Srivastava, B.; Stanislaus, T.D.S.; Staszak, D.; Strikhanov, M.; Stringfellow, B.; Suaide, A.A.P.; Suarez, M.C.; Subba, N.L.; Šumbera, Michal; Sun, X.M.; Sun, Y.; Sun, Z.; Surrow, B.; Symons, T.J.M.; de Toledo, A. S.; Takahashi, J.; Tang, A.H.; Tang, Z.; Tarini, L.H.; Tarnowsky, T.; Thein, D.; Thomas, J.H.; Tian, J.; Timmins, A.R.; Timoshenko, S.; Tlustý, David; Tokarev, M. V.; Trainor, T.A.; Tram, V.N.; Trattner, A.L.; Trentalange, S.; Tribble, R. E.; Tsai, O.D.; Ulery, J.; Ullrich, T.; Underwood, D.G.; Van Buren, G.; van Leeuwen, M.; van Nieuwenhuizen, G.; Vanfossen, J.A.; Varma, R.; Vasconcelos, G.M.S.; Vasiliev, A. N.; Videbaek, F.; Vigdor, S.E.; Viyogi, Y. P.; Vokal, S.; Voloshin, S.A.; Wada, M.; Walker, M.; Wang, F.; Wang, G.; Wang, H.; Wang, J.S.; Wang, Q.; Wang, X.; Wang, X.L.; Wang, Y.; Webb, G.; Westfall, G.D.; Whitten, C.; Wieman, H.; Wissink, S.W.; Witt, R.; Wu, Y.; Xie, W.; Xu, N.; Xu, Q.H.; Xu, Y.; Xu, Z.; Yang, Y.; Yepes, P.; Yip, K.; Yoo, K.-Y.; Yue, Q.; Zawisza, M.; Zbroszczyk, H.; Zhan, W.; Zhang, S.; Zhang, W.M.; Zhang, X.P.; Zhang, Y.; Zhang, Z.P.; Zhao, Y.; Zhong, C.; Zhou, J.; Zhu, X.; Zoulkarneev, R.; Zoulkarneeva, Y.; Zuo, J.X.

    2010-01-01

    Roč. 832, 1-2 (2010), s. 134-147 ISSN 0375-9474 R&D Projects: GA ČR GA202/07/0079; GA MŠk LA09013 Institutional research plan: CEZ:AV0Z10480505; CEZ:AV0Z10100502 Keywords : particle production * photons * forward rapidity Subject RIV: BG - Nuclear, Atomic and Molecular Physics, Colliders Impact factor: 1.986, year: 2010

  19. Romer Labs RapidChek®Listeria monocytogenes Test System for the Detection of L. monocytogenes on Selected Foods and Environmental Surfaces.

    Science.gov (United States)

    Juck, Gregory; Gonzalez, Verapaz; Allen, Ann-Christine Olsson; Sutzko, Meredith; Seward, Kody; Muldoon, Mark T

    2018-04-27

    The Romer Labs RapidChek ® Listeria monocytogenes test system (Performance Tested Method ℠ 011805) was validated against the U.S. Department of Agriculture-Food Safety and Inspection Service Microbiology Laboratory Guidebook (USDA-FSIS/MLG), U.S. Food and Drug Association Bacteriological Analytical Manual (FDA/BAM), and AOAC Official Methods of Analysis ℠ (AOAC/OMA) cultural reference methods for the detection of L. monocytogenes on selected foods including hot dogs, frozen cooked breaded chicken, frozen cooked shrimp, cured ham, and ice cream, and environmental surfaces including stainless steel and plastic in an unpaired study design. The RapidChek method uses a proprietary enrichment media system, a 44-48 h enrichment at 30 ± 1°C, and detects L. monocytogenes on an immunochromatographic lateral flow device within 10 min. Different L. monocytogenes strains were used to spike each of the matrixes. Samples were confirmed based on the reference method confirmations and an alternate confirmation method. A total of 140 low-level spiked samples were tested by the RapidChek method after enrichment for 44-48 h in parallel with the cultural reference method. There were 88 RapidChek presumptive positives. One of the presumptive positives was not confirmed culturally. Additionally, one of the culturally confirmed samples did not exhibit a presumptive positive. No difference between the alternate confirmation method and reference confirmation method was observed. The respective cultural reference methods (USDA-FSIS/MLG, FDA/BAM, and AOAC/OMA) produced a total of 63 confirmed positive results. Nonspiked samples from all foods were reported as negative for L. monocytogenes by all methods. Probability of detection analysis demonstrated no significant differences in the number of positive samples detected by the RapidChek method and the respective cultural reference method.

  20. Evaluating quality management systems for HIV rapid testing services in primary healthcare clinics in rural KwaZulu-Natal, South Africa

    OpenAIRE

    Jaya, Ziningi; Drain, Paul K.; Mashamba-Thompson, Tivani P.

    2017-01-01

    Introduction Rapid HIV tests have improved access to HIV diagnosis and treatment by providing quick and convenient testing in rural clinics and resource-limited settings. In this study, we evaluated the quality management system for voluntary and provider-initiated point-of-care HIV testing in primary healthcare (PHC) clinics in rural KwaZulu-Natal (KZN), South Africa. Material and methods We conducted a quality assessment audit in eleven PHC clinics that offer voluntary HIV testing and couns...

  1. Rapid microbiology - raising awareness.

    Science.gov (United States)

    Bailie, Jonathan

    2016-01-01

    A 'high-level overview' of some of the emerging rapid microbiology technologies designed to help healthcare engineering and infection control teams working in hospitals and other healthcare facilities more rapidly identify potentially hazardous levels of waterborne microorganisms in their water systems, enabling them to take prompt remedial action, and a look at the some of the 'pros and cons' of such testing techniques, was given by Nalco technical director, Howard Barnes, the vice-chair of the Legionella Control Association (LCA), at a recent LCA open day. HEJ editor, Jonathan Bailie, reports.

  2. Rapid characterization of microscopic two-level systems using Landau-Zener transitions in a superconducting qubit

    International Nuclear Information System (INIS)

    Tan, Xinsheng; Yu, Haifeng; Yu, Yang; Han, Siyuan

    2015-01-01

    We demonstrate a fast method to detect microscopic two-level systems in a superconducting phase qubit. By monitoring the population leak after sweeping the qubit bias flux, we are able to measure the two-level systems that are coupled with the qubit. Compared with the traditional method that detects two-level systems by energy spectroscopy, our method is faster and more sensitive. This method supplies a useful tool to investigate two-level systems in solid-state qubits

  3. Rapid determination of chromium(VI) in electroplating waste water by use of a spectrophotometric flow injection system.

    Science.gov (United States)

    Yuan, Dong; Fu, Dayou; Wang, Rong; Yuan, Jigang

    2008-11-01

    A new rapid and sensitive FI method is reported for spectrophotometric determination of trace chromium(VI) in electroplating waste water. The method is based on the reaction of Cr(VI) with sodium diphenylamine sulfonate (DPH) in acidic medium to form a purple complex (lambda(max) = 550 nm). Under the optimized conditions, the calibration curve is linear in the range 0.04-3.8 microg ml(-1) at a sampling rate of 30 h(-1). The detection limit of the method is 0.0217 microg ml(-1), and the relative standard deviation is 1.1% for eight determinations of 2 microg ml(-1) Cr(VI). The proposed method was applied to the determination of chromium in electroplating waste water with satisfactory results.

  4. The planning and management system of the low level radioactive waste transportation

    International Nuclear Information System (INIS)

    Tanaka, K.; Yoshida, K.; Miyamoto, J.; Sanui, T.; Noura, T.; Kitanishi, K.; Nara, S.

    1993-01-01

    Nuclear Fuel Transport Co, Ltd. (hereafter called NFT) was the first in Japan to transport low-level radioactive waste (LLW). It is now engaged in preparatory operations with the slogan 'Improved Safety and Reliability' and is introducing advanced mechanization systems to provide safety and reliability in software management such as transportation planning and transportation information management. The following is an introduction of these systems, which provide overall support in transportation planning determination and transportation management operations related to the LLW transportation cycle. (J.P.N.)

  5. Filter Measurement System for Nuclear Material Storage Canisters. End of Year Report FY 2013

    Energy Technology Data Exchange (ETDEWEB)

    Moore, Murray E. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Reeves, Kirk P. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2014-02-03

    A test system has been developed at Los Alamos National Laboratory to measure the aerosol collection efficiency of filters in the lids of storage canisters for special nuclear materials. Two FTS (filter test system) devices have been constructed; one will be used in the LANL TA-55 facility with lids from canisters that have stored nuclear material. The other FTS device will be used in TA-3 at the Radiation Protection Division’s Aerosol Engineering Facility. The TA-3 system will have an expanded analytical capability, compared to the TA-55 system that will be used for operational performance testing. The LANL FTS is intended to be automatic in operation, with independent instrument checks for each system component. The FTS has been described in a complete P&ID (piping and instrumentation diagram) sketch, included in this report. The TA-3 FTS system is currently in a proof-of-concept status, and TA-55 FTS is a production-quality prototype. The LANL specification for (Hagan and SAVY) storage canisters requires the filter shall “capture greater than 99.97% of 0.45-micron mean diameter dioctyl phthalate (DOP) aerosol at the rated flow with a DOP concentration of 65±15 micrograms per liter”. The percent penetration (PEN%) and pressure drop (DP) of fifteen (15) Hagan canister lids were measured by NFT Inc. (Golden, CO) over a period of time, starting in the year 2002. The Los Alamos FTS measured these quantities on June 21, 2013 and on Oct. 30, 2013. The LANL(6-21-2013) results did not statistically match the NFT Inc. data, and the LANL FTS system was re-evaluated, and the aerosol generator was replaced and the air flow measurement method was corrected. The subsequent LANL(10-30-2013) tests indicate that the PEN% results are statistically identical to the NFT Inc. results. The LANL(10-30-2013) pressure drop measurements are closer to the NFT Inc. data, but future work will be investigated. An operating procedure for the FTS (filter test system) was written, and

  6. A rapid culture system uninfluenced by an inoculum effect increases reliability and convenience for drug susceptibility testing of Mycobacterium tuberculosis.

    Science.gov (United States)

    Jung, Yong-Gyun; Kim, Hyejin; Lee, Sangyeop; Kim, Suyeoun; Jo, EunJi; Kim, Eun-Geun; Choi, Jungil; Kim, Hyun Jung; Yoo, Jungheon; Lee, Hye-Jeong; Kim, Haeun; Jung, Hyunju; Ryoo, Sungweon; Kwon, Sunghoon

    2018-06-05

    The Disc Agarose Channel (DAC) system utilizes microfluidics and imaging technologies and is fully automated and capable of tracking single cell growth to produce Mycobacterium tuberculosis (MTB) drug susceptibility testing (DST) results within 3~7 days. In particular, this system can be easily used to perform DSTs without the fastidious preparation of the inoculum of MTB cells. Inoculum effect is one of the major problems that causes DST errors. The DAC system was not influenced by the inoculum effect and produced reliable DST results. In this system, the minimum inhibitory concentration (MIC) values of the first-line drugs were consistent regardless of inoculum sizes ranging from ~10 3 to ~10 8 CFU/mL. The consistent MIC results enabled us to determine the critical concentrations for 12 anti-tuberculosis drugs. Based on the determined critical concentrations, further DSTs were performed with 254 MTB clinical isolates without measuring an inoculum size. There were high agreement rates (96.3%) between the DAC system and the absolute concentration method using Löwenstein-Jensen medium. According to these results, the DAC system is the first DST system that is not affected by the inoculum effect. It can thus increase reliability and convenience for DST of MTB. We expect that this system will be a potential substitute for conventional DST systems.

  7. Rapid quantification of vesicle concentration for DOPG/DOPC and Cardiolipin/DOPC mixed lipid systems of variable composition.

    Science.gov (United States)

    Elmer-Dixon, Margaret M; Bowler, Bruce E

    2018-05-19

    A novel approach to quantify mixed lipid systems is described. Traditional approaches to lipid vesicle quantification are time consuming, require large amounts of material and are destructive. We extend our recently described method for quantification of pure lipid systems to mixed lipid systems. The method only requires a UV-Vis spectrometer and does not destroy sample. Mie scattering data from absorbance measurements are used as input into a Matlab program to calculate the total vesicle concentration and the concentrations of each lipid in the mixed lipid system. The technique is fast and accurate, which is essential for analytical lipid binding experiments. Copyright © 2018. Published by Elsevier Inc.

  8. The method of normal forms for singularly perturbed systems of Fredholm integro-differential equations with rapidly varying kernels

    Energy Technology Data Exchange (ETDEWEB)

    Bobodzhanov, A A; Safonov, V F [National Research University " Moscow Power Engineering Institute" , Moscow (Russian Federation)

    2013-07-31

    The paper deals with extending the Lomov regularization method to classes of singularly perturbed Fredholm-type integro-differential systems, which have not so far been studied. In these the limiting operator is discretely noninvertible. Such systems are commonly known as problems with unstable spectrum. Separating out the essential singularities in the solutions to these problems presents great difficulties. The principal one is to give an adequate description of the singularities induced by 'instability points' of the spectrum. A methodology for separating singularities by using normal forms is developed. It is applied to the above type of systems and is substantiated in these systems. Bibliography: 10 titles.

  9. Rapid Precipitation of Amorphous Silica in Experimental Systems with Nontronite (NAu-1) and Shewanella oneidensis MR-1

    National Research Council Canada - National Science Library

    Furukawa, Yoko; O'Reilly, S. E

    2007-01-01

    ...) silica globule formation was confirmed in the immediate vicinity of bacterial cells and extracellular polymeric substances in all experimental systems that contained bacteria, whether the bacteria...

  10. Calibration transfer between electronic nose systems for rapid In situ measurement of pulp and paper industry emissions

    International Nuclear Information System (INIS)

    Deshmukh, Sharvari; Kamde, Kalyani; Jana, Arun; Korde, Sanjivani; Bandyopadhyay, Rajib; Sankar, Ravi; Bhattacharyya, Nabarun; Pandey, R.A.

    2014-01-01

    Highlights: • E-nose developed for obnoxious emissions measurement at pulp and paper industrial site. • ANN model developed for prediction of (CH 3 ) 2 S, (CH 3 ) 2 S 2 , CH 3 SH and H 2 S concentration. • Calibration transfer methodology developed for transfer between two e-nose instruments. • Box–Behnken design and robust regression used for calibration transfer. • Results show effective transfer of training model from one e-nose system to other. - Abstract: Electronic nose systems when deployed in network mesh can effectively provide a low budget and onsite solution for the industrial obnoxious gaseous measurement. For accurate and identical prediction capability by all the electronic nose systems, a reliable calibration transfer model needs to be implemented in order to overcome the inherent sensor array variability. In this work, robust regression (RR) is used for calibration transfer between two electronic nose systems using a Box–Behnken (BB) design. Out of the two electronic nose systems, one was trained using industrial gas samples by four artificial neural network models, for the measurement of obnoxious odours emitted from pulp and paper industries. The emissions constitute mainly of hydrogen sulphide (H 2 S), methyl mercaptan (MM), dimethyl sulphide (DMS) and dimethyl disulphide (DMDS) in different proportions. A Box–Behnken design consisting of 27 experiment sets based on synthetic gas combinations of H 2 S, MM, DMS and DMDS, were conducted for calibration transfer between two identical electronic nose systems. Identical sensors on both the systems were mapped and the prediction models developed using ANN were then transferred to the second system using BB–RR methodology. The results showed successful transmission of prediction models developed for one system to other system, with the mean absolute error between the actual and predicted concentration of analytes in mg L −1 after calibration transfer (on second system) being 0.076, 0

  11. A novel system for rapid measurement of high-frequency magnetic properties of toroidal cores of different sizes

    CERN Document Server

    Derebasi, N; Moses, A J; Fox, D

    2000-01-01

    A novel system for power loss and B-H measurements on toroidal magnetic cores was built to operate up to 200 kHz. Measurement data taken using sophisticated software at 10 MHz sampling rate and 16-bit resolution shows the system is versatile and can be used to test a wide range of core sizes and materials with an error <+-3%.

  12. Experimental Verification of a Pneumatic Transport System for the Rapid Evacuation of Tunnels, Part II - Test Program

    Science.gov (United States)

    1978-12-01

    This study is the final phase of a muck pipeline program begun in 1973. The objective of the study was to evaluate a pneumatic pipeline system for muck haulage from a tunnel excavated by a tunnel boring machine. The system was comprised of a muck pre...

  13. Flow Injection/Sequential Injection Analysis Systems: Potential Use as Tools for Rapid Liver Diseases Biomarker Study

    Directory of Open Access Journals (Sweden)

    Supaporn Kradtap Hartwell

    2012-01-01

    Full Text Available Flow injection/sequential injection analysis (FIA/SIA systems are suitable for carrying out automatic wet chemical/biochemical reactions with reduced volume and time consumption. Various parts of the system such as pump, valve, and reactor may be built or adapted from available materials. Therefore the systems can be at lower cost as compared to other instrumentation-based analysis systems. Their applications for determination of biomarkers for liver diseases have been demonstrated in various formats of operation but only a few and limited types of biomarkers have been used as model analytes. This paper summarizes these applications for different types of reactions as a guide for using flow-based systems in more biomarker and/or multibiomarker studies.

  14. Integrated microfluidic system for rapid screening of CRP aptamers utilizing systematic evolution of ligands by exponential enrichment (SELEX).

    Science.gov (United States)

    Huang, Chao-June; Lin, Hsin-I; Shiesh, Shu-Chu; Lee, Gwo-Bin

    2010-03-15

    The systematic evolution of ligands by exponential enrichment (SELEX) is an experimental procedure that allows screening of given molecular targets by desired binding affinities from an initial random pool of oligonucleotides and oligomers. The final products of SELEX are usually referred as aptamers, which are recognized as promising molecules for a variety of biomedical applications. However, SELEX is an iterative process requiring multiple rounds of extraction and amplification that demands significant time and labor. Therefore, this study presents a novel, automatic, miniature SELEX platform. As a demonstration, the rapid screening of C-reactive protein (CRP) aptamers was performed. By utilizing microfluidic technologies and magnetic beads conjugated with CRP, aptamers with a high affinity to CRP were extracted from a random single-strand deoxyribonucleic acid (ssDNA) pool. These aptamers were further amplified by an on-chip polymerase chain reaction (PCR) process. After five consecutive extraction and amplification cycles, a specific aptamer with the highest affinity was screened automatically. The screened aptamers were used as a recognition molecule for the detection of CRP. The developed microsystem demonstrated fast screening of CRP aptamers and can be used as a powerful tool to select analyte-specific aptamers for biomedical applications. (c) 2009 Elsevier B.V. All rights reserved.

  15. Distribution and source analysis of heavy metal pollutants in sediments of a rapid developing urban river system.

    Science.gov (United States)

    Xia, Fang; Qu, Liyin; Wang, Ting; Luo, Lili; Chen, Han; Dahlgren, Randy A; Zhang, Minghua; Mei, Kun; Huang, Hong

    2018-09-01

    Heavy metal pollution of aquatic environments in rapidly developing industrial regions is of considerable global concern due to its potential to cause serious harm to aquatic ecosystems and human health. This study assessed heavy metal contamination of sediments in a highly industrialized urban watershed of eastern China containing several historically unregulated manufacturing enterprises. Total concentrations and solid-phase fractionation of Cu, Zn, Pb, Cr and Cd were investigated for 39 river sediments using multivariate statistical analysis and geographically weighted regression (GWR) methods to quantitatively examine the relationship between land use and heavy metal pollution at the watershed scale. Results showed distinct spatial patterns of heavy metal contamination within the watershed, such as higher concentrations of Zn, Pb and Cd in the southwest and higher Cu concentration in the east, indicating links to specific pollution sources within the watershed. Correlation and PCA analyses revealed that Zn, Pb and Cd were dominantly contributed by anthropogenic activities; Cu originated from both industrial and agricultural sources; and Cr has been altered by recent pollution control strategies. The GWR model indicated that several heavy metal fractions were strongly correlated with industrial land proportion and this correlation varied with the level of industrialization as demonstrated by variations in local GWR R 2 values. This study provides important information for assessing heavy metal contaminated areas, identifying heavy metal pollutant sources, and developing regional-scale remediation strategies. Copyright © 2018 Elsevier Ltd. All rights reserved.

  16. Rapid experimental evolution of pesticide resistance in C. elegans entails no costs and affects the mating system.

    Directory of Open Access Journals (Sweden)

    Patricia C Lopes

    Full Text Available Pesticide resistance is a major concern in natural populations and a model trait to study adaptation. Despite the importance of this trait, the dynamics of its evolution and of its ecological consequences remain largely unstudied. To fill this gap, we performed experimental evolution with replicated populations of Caenorhabditis elegans exposed to the pesticide Levamisole during 20 generations. Exposure to Levamisole resulted in decreased survival, fecundity and male frequency, which declined from 30% to zero. This was not due to differential susceptibility of males. Rather, the drug affected mobility, resulting in fewer encounters, probably leading to reduced outcrossing rates. Adaptation, i.e., increased survival and fecundity, occurred within 10 and 20 generations, respectively. Male frequency also increased by generation 20. Adaptation costs were undetected in the ancestral environment and in presence of Ivermectin, another widely-used pesticide with an opposite physiological effect. Our results demonstrate that pesticide resistance can evolve at an extremely rapid pace. Furthermore, we unravel the effects of behaviour on life-history traits and test the environmental dependence of adaptation costs. This study establishes experimental evolution as a powerful tool to tackle pesticide resistance, and paves the way to further investigations manipulating environmental and/or genetic factors underlying adaptation to pesticides.

  17. Using an aqueous two-phase polymer-salt system to rapidly concentrate viruses for improving the detection limit of the lateral-flow immunoassay.

    Science.gov (United States)

    Jue, Erik; Yamanishi, Cameron D; Chiu, Ricky Y T; Wu, Benjamin M; Kamei, Daniel T

    2014-12-01

    The development of point-of-need (PON) diagnostics for viruses has the potential to prevent pandemics and protects against biological warfare threats. Here we discuss the approach of using aqueous two-phase systems (ATPSs) to concentrate biomolecules prior to the lateral-flow immunoassay (LFA) for improved viral detection. In this paper, we developed a rapid PON detection assay as an extension to our previous proof-of-concept studies which used a micellar ATPS. We present our investigation of a more rapid polymer-salt ATPS that can drastically improve the assay time, and show that the phase containing the concentrated biomolecule can be extracted prior to macroscopic phase separation equilibrium without affecting the measured biomolecule concentration in that phase. We could therefore significantly decrease the time of the diagnostic assay with an early extraction time of just 30 min. Using this rapid ATPS, the model virus bacteriophage M13 was concentrated between approximately 2 and 10-fold by altering the volume ratio between the two phases. As the extracted virus-rich phase contained a high salt concentration which destabilized the colloidal gold indicator used in LFA, we decorated the gold nanoprobes with polyethylene glycol (PEG) to provide steric stabilization, and used these nanoprobes to demonstrate a 10-fold improvement in the LFA detection limit. Lastly, a MATLAB script was used to quantify the LFA results with and without the pre-concentration step. This approach of combining a rapid ATPS with LFA has great potential for PON applications, especially as greater concentration-fold improvements can be achieved by further varying the volume ratio. Biotechnol. Bioeng. 2014;111: 2499-2507. © 2014 Wiley Periodicals, Inc. © 2014 Wiley Periodicals, Inc.

  18. How Big Data, Comparative Effectiveness Research, and Rapid-Learning Health-Care Systems Can Transform Patient Care in Radiation Oncology.

    Science.gov (United States)

    Sanders, Jason C; Showalter, Timothy N

    2018-01-01

    Big data and comparative effectiveness research methodologies can be applied within the framework of a rapid-learning health-care system (RLHCS) to accelerate discovery and to help turn the dream of fully personalized medicine into a reality. We synthesize recent advances in genomics with trends in big data to provide a forward-looking perspective on the potential of new advances to usher in an era of personalized radiation therapy, with emphases on the power of RLHCS to accelerate discovery and the future of individualized radiation treatment planning.

  19. Development of a fully automated software system for rapid analysis/processing of the falling weight deflectometer data.

    Science.gov (United States)

    2009-02-01

    The Office of Special Investigations at Iowa Department of Transportation (DOT) collects FWD data on regular basis to evaluate pavement structural conditions. The primary objective of this study was to develop a fully-automated software system for ra...

  20. Calibration transfer between electronic nose systems for rapid In situ measurement of pulp and paper industry emissions

    Energy Technology Data Exchange (ETDEWEB)

    Deshmukh, Sharvari [CSIR-National Environmental Engineering and Research Institute, Nagpur (India); Department of Instrumentation and Electronics Engineering, Jadavpur University, Kolkata (India); Kamde, Kalyani [CSIR-National Environmental Engineering and Research Institute, Nagpur (India); Jana, Arun [Center for Development of Advance Computing, Kolkata (India); Korde, Sanjivani [CSIR-National Environmental Engineering and Research Institute, Nagpur (India); Bandyopadhyay, Rajib [Department of Instrumentation and Electronics Engineering, Jadavpur University, Kolkata (India); Sankar, Ravi [Center for Development of Advance Computing, Kolkata (India); Bhattacharyya, Nabarun, E-mail: nabarun.bhattacharya@cdac.in [Center for Development of Advance Computing, Kolkata (India); Pandey, R.A., E-mail: ra_pandey@neeri.res.in [CSIR-National Environmental Engineering and Research Institute, Nagpur (India)

    2014-09-02

    Highlights: • E-nose developed for obnoxious emissions measurement at pulp and paper industrial site. • ANN model developed for prediction of (CH{sub 3}){sub 2}S, (CH{sub 3}){sub 2}S{sub 2}, CH{sub 3}SH and H{sub 2}S concentration. • Calibration transfer methodology developed for transfer between two e-nose instruments. • Box–Behnken design and robust regression used for calibration transfer. • Results show effective transfer of training model from one e-nose system to other. - Abstract: Electronic nose systems when deployed in network mesh can effectively provide a low budget and onsite solution for the industrial obnoxious gaseous measurement. For accurate and identical prediction capability by all the electronic nose systems, a reliable calibration transfer model needs to be implemented in order to overcome the inherent sensor array variability. In this work, robust regression (RR) is used for calibration transfer between two electronic nose systems using a Box–Behnken (BB) design. Out of the two electronic nose systems, one was trained using industrial gas samples by four artificial neural network models, for the measurement of obnoxious odours emitted from pulp and paper industries. The emissions constitute mainly of hydrogen sulphide (H{sub 2}S), methyl mercaptan (MM), dimethyl sulphide (DMS) and dimethyl disulphide (DMDS) in different proportions. A Box–Behnken design consisting of 27 experiment sets based on synthetic gas combinations of H{sub 2}S, MM, DMS and DMDS, were conducted for calibration transfer between two identical electronic nose systems. Identical sensors on both the systems were mapped and the prediction models developed using ANN were then transferred to the second system using BB–RR methodology. The results showed successful transmission of prediction models developed for one system to other system, with the mean absolute error between the actual and predicted concentration of analytes in mg L{sup −1} after calibration

  1. Evaluating quality management systems for HIV rapid testing services in primary healthcare clinics in rural KwaZulu-Natal, South Africa.

    Directory of Open Access Journals (Sweden)

    Ziningi Jaya

    Full Text Available Rapid HIV tests have improved access to HIV diagnosis and treatment by providing quick and convenient testing in rural clinics and resource-limited settings. In this study, we evaluated the quality management system for voluntary and provider-initiated point-of-care HIV testing in primary healthcare (PHC clinics in rural KwaZulu-Natal (KZN, South Africa.We conducted a quality assessment audit in eleven PHC clinics that offer voluntary HIV testing and counselling in rural KZN, South Africa from August 2015 to October 2016. All the participating clinics were purposively selected from the province-wide survey of diagnostic services. We completed an on-site monitoring checklist, adopted from the WHO guidelines for assuring accuracy and reliability of HIV rapid tests, to assess the quality management system for HIV rapid testing at each clinic. To determine clinic's compliance to WHO quality standards for HIV rapid testing the following quality measure was used, a 3-point scale (high, moderate and poor. A high score was defined as a percentage rating of 90 to 100%, moderate was defined as a percentage rating of 70 to 90%, and poor was defined as a percentage rating of less than 70%. Clinic audit scores were summarized and compared. We employed Pearson pair wise correlation coefficient to determine correlations between clinics audit scores and clinic and clinics characteristics. Linear regression model was computed to estimate statistical significance of the correlates. Correlations were reported as significant at p ≤0.05.Nine out of 11 audited rural PHC clinics are located outside 20Km of the nearest town and hospital. Majority (18.2% of the audited rural PHC clinics reported that HIV rapid test was performed by HIV lay counsellors. Overall, ten clinics were rated moderate, in terms of their compliance to the stipulated WHO guidelines. Audit results showed that rural PHC clinics' average rating score for compliance to the WHO guidelines ranged

  2. Evaluating quality management systems for HIV rapid testing services in primary healthcare clinics in rural KwaZulu-Natal, South Africa.

    Science.gov (United States)

    Jaya, Ziningi; Drain, Paul K; Mashamba-Thompson, Tivani P

    2017-01-01

    Rapid HIV tests have improved access to HIV diagnosis and treatment by providing quick and convenient testing in rural clinics and resource-limited settings. In this study, we evaluated the quality management system for voluntary and provider-initiated point-of-care HIV testing in primary healthcare (PHC) clinics in rural KwaZulu-Natal (KZN), South Africa. We conducted a quality assessment audit in eleven PHC clinics that offer voluntary HIV testing and counselling in rural KZN, South Africa from August 2015 to October 2016. All the participating clinics were purposively selected from the province-wide survey of diagnostic services. We completed an on-site monitoring checklist, adopted from the WHO guidelines for assuring accuracy and reliability of HIV rapid tests, to assess the quality management system for HIV rapid testing at each clinic. To determine clinic's compliance to WHO quality standards for HIV rapid testing the following quality measure was used, a 3-point scale (high, moderate and poor). A high score was defined as a percentage rating of 90 to 100%, moderate was defined as a percentage rating of 70 to 90%, and poor was defined as a percentage rating of less than 70%. Clinic audit scores were summarized and compared. We employed Pearson pair wise correlation coefficient to determine correlations between clinics audit scores and clinic and clinics characteristics. Linear regression model was computed to estimate statistical significance of the correlates. Correlations were reported as significant at p ≤0.05. Nine out of 11 audited rural PHC clinics are located outside 20Km of the nearest town and hospital. Majority (18.2%) of the audited rural PHC clinics reported that HIV rapid test was performed by HIV lay counsellors. Overall, ten clinics were rated moderate, in terms of their compliance to the stipulated WHO guidelines. Audit results showed that rural PHC clinics' average rating score for compliance to the WHO guidelines ranged between 64.4% (CI

  3. A simple Cr(VI)–S(IV)–O{sub 2} system for rapid and simultaneous reduction of Cr(VI) and oxidative degradation of organic pollutants

    Energy Technology Data Exchange (ETDEWEB)

    Yuan, Yanan; Yang, Shaojie [Department of Environmental Science, Hubei Key Lab of Biomass Resource Chemistry and Environmental Biotechnology, School of Resources and Environmental Science, Wuhan University, 430079 (China); Zhou, Danna, E-mail: zdncug@163.com [Faculty of Material Science and Chemistry, China University of Geosciences, Wuhan 430074 (China); Wu, Feng [Department of Environmental Science, Hubei Key Lab of Biomass Resource Chemistry and Environmental Biotechnology, School of Resources and Environmental Science, Wuhan University, 430079 (China)

    2016-04-15

    Highlights: • Rapid and simultaneous reduction of Cr(VI) and degradation of organic pollutants occur. • Oxysulfur radicals generated in Cr(VI)–S(IV)–O{sub 2} system oxidize the organic pollutants. • Acidic pH facilitates the reactions from both directions of reduction and oxidation. • Degradation potential of aromatic amines depends on the substituted groups. • Cr(VI)–S(IV)–O{sub 2} system is promising for “waste control by waste”. - Abstract: Hexavalent chromium (Cr(VI)), a heavy-metal contaminant, can be easily reduced to less toxic trivalent chromium (Cr(III)) by sulfite ions (S(IV)). However, S(IV) has not drawn as much attention as the ferrous ion has. We report herein a novel Cr(VI)–S(IV)–O{sub 2} system containing sulfite ions that rapidly and simultaneously reduces Cr(VI) and oxidize organic pollutants in the presence of oxygen in aqueous solutions. This Cr(VI)–S(IV)-O{sub 2} system contains the initiator Cr(VI), the reductant S(IV), and the oxidant O{sub 2}, which produce oxysulfur radicals (mainly SO{sub 4}·{sup −} and SO{sub 5}·{sup −}) and hydroxyl radicals (OH·). The Cr(VI)/S(IV) molar ratio, pH, and oxygen content play important roles in the entire reaction system. Acidic conditions (pH 3.0) facilitated degradation of organic compounds and reduction of Cr(VI) as well. In addition, experiments of rapid degradation of several kinds of organic pollutants such as azo dye (acid orange 7, AO7), aniline, phenol, bisphenol A etc were also conducted. Preliminary results show that the removal rates of the analogs of phenols or aromatic amines in this Cr(VI)–S(IV)–O{sub 2} system have a relationship with the electronic parameters (Hammett constant, σ) of the substituted groups. Thus, the Cr(VI)–S(IV)–O{sub 2} system, provides an excellent strategy of “waste control by waste” for removing multiple industrial contaminants.

  4. Rapid and simple detection of foot-and-mouth disease virus: Evaluation of a cartridge-based molecular detection system for use in basic laboratories.

    Science.gov (United States)

    Goller, K V; Dill, V; Madi, M; Martin, P; Van der Stede, Y; Vandenberge, V; Haas, B; Van Borm, S; Koenen, F; Kasanga, C J; Ndusilo, N; Beer, M; Liu, L; Mioulet, V; Armson, B; King, D P; Fowler, V L

    2018-04-01

    Highly contagious transboundary animal diseases such as foot-and-mouth disease (FMD) are major threats to the productivity of farm animals. To limit the impact of outbreaks and to take efficient steps towards a timely control and eradication of the disease, rapid and reliable diagnostic systems are of utmost importance. Confirmatory diagnostic assays are typically performed by experienced operators in specialized laboratories, and access to this capability is often limited in the developing countries with the highest disease burden. Advances in molecular technologies allow implementation of modern and reliable techniques for quick and simple pathogen detection either in basic laboratories or even at the pen-side. Here, we report on a study to evaluate a fully automated cartridge-based real-time RT-PCR diagnostic system (Enigma MiniLab ® ) for the detection of FMD virus (FMDV). The modular system integrates both nucleic acid extraction and downstream real-time RT-PCR (rRT-PCR). The analytical sensitivity of this assay was determined using serially diluted culture grown FMDV, and the performance of the assay was evaluated using a selected range of FMDV positive and negative clinical samples of bovine, porcine and ovine origin. The robustness of the assay was evaluated in an international inter-laboratory proficiency test and by deployment into an African laboratory. It was demonstrated that the system is easy to use and can detect FMDV with high sensitivity and specificity, roughly on par with standard laboratory methods. This cartridge-based automated real-time RT-PCR system for the detection of FMDV represents a reliable and easy to use diagnostic tool for the early and rapid disease detection of acutely infected animals even in remote areas. This type of system could be easily deployed for routine surveillance within endemic regions such as Africa or could alternatively be used in the developed world. © 2017 The Authors. Transboundary and Emerging Diseases

  5. 3-Bromopyruvate induces rapid human prostate cancer cell death by affecting cell energy metabolism, GSH pool and the glyoxalase system.

    Science.gov (United States)

    Valenti, Daniela; Vacca, Rosa A; de Bari, Lidia

    2015-12-01

    3-bromopyruvate (3-BP) is an anti-tumour drug effective on hepatocellular carcinoma and other tumour cell types, which affects both glycolytic and mitochondrial targets, depleting cellular ATP pool. Here we tested 3-BP on human prostate cancer cells showing, differently from other tumour types, efficient ATP production and functional mitochondrial metabolism. We found that 3-BP rapidly induced cultured androgen-insensitive (PC-3) and androgen-responsive (LNCaP) prostate cancer cell death at low concentrations (IC(50) values of 50 and 70 μM, respectively) with a multimodal mechanism of action. In particular, 3-BP-treated PC-3 cells showed a selective, strong reduction of glyceraldeide 3-phosphate dehydrogenase activity, due to the direct interaction of the drug with the enzyme. Moreover, 3-BP strongly impaired both glutamate/malate- and succinate-dependent mitochondrial respiration, membrane potential generation and ATP synthesis, concomitant with the inhibition of respiratory chain complex I, II and ATP synthase activities. The drastic reduction of cellular ATP levels and depletion of GSH pool, associated with significant increase in cell oxidative stress, were found after 3-BP treatment of PC-3 cells. Interestingly, the activity of both glyoxalase I and II, devoted to the elimination of the cytotoxic methylglyoxal, was strongly inhibited by 3-BP. Both N-acetylcysteine and aminoguanidine, GSH precursor and methylglyoxal scavenger, respectively, prevented 3-BP-induced PC-3 cell death, showing that impaired cell antioxidant and detoxifying capacities are crucial events leading to cell death. The provided information on the multi-target cytotoxic action of 3-BP, finally leading to PC-3 cell necrosis, might be useful for future development of 3-BP as a therapeutic option for prostate cancer treatment.

  6. A computer vision system for rapid search inspired by surface-based attention mechanisms from human perception.

    Science.gov (United States)

    Mohr, Johannes; Park, Jong-Han; Obermayer, Klaus

    2014-12-01

    Humans are highly efficient at visual search tasks by focusing selective attention on a small but relevant region of a visual scene. Recent results from biological vision suggest that surfaces of distinct physical objects form the basic units of this attentional process. The aim of this paper is to demonstrate how such surface-based attention mechanisms can speed up a computer vision system for visual search. The system uses fast perceptual grouping of depth cues to represent the visual world at the level of surfaces. This representation is stored in short-term memory and updated over time. A top-down guided attention mechanism sequentially selects one of the surfaces for detailed inspection by a recognition module. We show that the proposed attention framework requires little computational overhead (about 11 ms), but enables the system to operate in real-time and leads to a substantial increase in search efficiency. Copyright © 2014 Elsevier Ltd. All rights reserved.

  7. Contrast-enhanced MR venography of the head using magnetization prepared rapid gradient echo imaging. Comparison between head and body radiofrequency transmitter coil systems

    International Nuclear Information System (INIS)

    Matsunobu, Satosi; Amanuma, Makoto; Tsukuda, Shunji

    2004-01-01

    The purpose of this study was to evaluate the image quality and vascular selectivity of MR venography of the head using an magnetization prepared rapid gradient echo (MP-RAGE) technique when obtained with a body radiofrequency transmitter coil system. A total of 24 patients were imaged with a head or body radiofrequency (RF) transmission system. Subtraction MR angiography (MRA) was processed with 0.1 mmol Gd-DTPA administration, and signal-to-noise ratios of the vascular system were measured. Venous demonstration and selectivity were also assessed. MP-RAGE MR venography with a body transmission system showed almost the same signal intensity for the venous and arterial systems, resulting in nonspecific vascular demonstration, while the head transmission system showed semi-selective venograms owing to inflow-induced high signal on precontrast images. However, MRA with a body transmission system provided a 1.5- to 2.5-fold higher signal-to-noise ratios based on higher gradient performance and excellent demonstration of the head veins, especially those below the skull base. Although selective venography was difficult, MRA with a body transmission coil provided excellent vascular images of the brain. (author)

  8. Reaching a 1.5°C target: socio-technical challenges for a rapid transition to low-carbon electricity systems.

    Science.gov (United States)

    Eyre, Nick; Darby, Sarah J; Grünewald, Philipp; McKenna, Eoghan; Ford, Rebecca

    2018-05-13

    A 1.5°C global average target implies that we should no longer focus on merely incremental emissions reductions from the electricity system, but rather on fundamentally re-envisaging a system that, sooner rather than later, becomes carbon free. Many low-carbon technologies are surpassing mainstream predictions for both uptake and cost reduction. Their deployment is beginning to be disruptive within established systems. 'Smart technologies' are being developed to address emerging challenges of system integration, but their rates of future deployment remain uncertain. We argue that transition towards a system that can fully displace carbon generation sources will require expanding the focus of our efforts beyond technical solutions. Recognizing that change has social and technical dimensions, and that these interact strongly, we set out a socio-technical review that covers electricity infrastructure, citizens, business models and governance. It describes some of the socio-technical challenges that need to be addressed for the successful transition of the existing electricity systems. We conclude that a socio-technical understanding of electricity system transitions offers new and better insights into the potential and challenges for rapid decarbonization.This article is part of the theme issue 'The Paris Agreement: understanding the physical and social challenges for a warming world of 1.5°C above pre-industrial levels'. © 2018 The Author(s).

  9. Design of Soil Salinity Policies with Tinamit, a Flexible and Rapid Tool to Couple Stakeholder-Built System Dynamics Models with Physically-Based Models

    Science.gov (United States)

    Malard, J. J.; Baig, A. I.; Hassanzadeh, E.; Adamowski, J. F.; Tuy, H.; Melgar-Quiñonez, H.

    2016-12-01

    Model coupling is a crucial step to constructing many environmental models, as it allows for the integration of independently-built models representing different system sub-components to simulate the entire system. Model coupling has been of particular interest in combining socioeconomic System Dynamics (SD) models, whose visual interface facilitates their direct use by stakeholders, with more complex physically-based models of the environmental system. However, model coupling processes are often cumbersome and inflexible and require extensive programming knowledge, limiting their potential for continued use by stakeholders in policy design and analysis after the end of the project. Here, we present Tinamit, a flexible Python-based model-coupling software tool whose easy-to-use API and graphical user interface make the coupling of stakeholder-built SD models with physically-based models rapid, flexible and simple for users with limited to no coding knowledge. The flexibility of the system allows end users to modify the SD model as well as the linking variables between the two models themselves with no need for recoding. We use Tinamit to couple a stakeholder-built socioeconomic model of soil salinization in Pakistan with the physically-based soil salinity model SAHYSMOD. As climate extremes increase in the region, policies to slow or reverse soil salinity buildup are increasing in urgency and must take both socioeconomic and biophysical spheres into account. We use the Tinamit-coupled model to test the impact of integrated policy options (economic and regulatory incentives to farmers) on soil salinity in the region in the face of future climate change scenarios. Use of the Tinamit model allowed for rapid and flexible coupling of the two models, allowing the end user to continue making model structure and policy changes. In addition, the clear interface (in contrast to most model coupling code) makes the final coupled model easily accessible to stakeholders with

  10. Rapid quantification of viable Legionella in nuclear cooling tower waters using filter cultivation, fluorescent in situ hybridization and solid-phase cytometry.

    Science.gov (United States)

    Baudart, J; Guillaume, C; Mercier, A; Lebaron, P; Binet, M

    2015-05-01

    To develop a rapid and sensitive method to quantify viable Legionella spp. in cooling tower water samples. A rapid, culture-based method capable of quantifying as few as 600 Legionella microcolonies per litre within 2 days in industrial waters was developed. The method combines a short cultivation step of microcolonies on GVPC agar plate, specific detection of Legionella cells by a fluorescent in situ hybridization (FISH) approach, and a sensitive enumeration using a solid-phase cytometer. Following optimization of the cultivation conditions, the qualitative and quantitative performance of the method was assessed and the method was applied to 262 nuclear power plant cooling water samples. The performance of this method was in accordance with the culture method (NF-T 90-431) for Legionella enumeration. The rapid detection of viable Legionella in water is a major concern to the effective monitoring of this pathogenic bacterium in the main water sources involved in the transmission of legionellosis infection (Legionnaires' disease). The new method proposed here appears to be a robust, efficient and innovative means for rapidly quantifying cultivable Legionella in cooling tower water samples within 48 h. © 2015 The Society for Applied Microbiology.

  11. Pre-storage of gelified reagents in a lab-on-a-foil system for rapid nucleic acid analysis

    DEFF Research Database (Denmark)

    Yi, Sun; Høgberg, Jonas; Christine, Thanner

    2013-01-01

    Reagent pre-storage in a microfluidic chip can enhance operator convenience, simplify the system design, reduce the cost of storage and shipment, and avoid the risk of cross-contamination. Although dry reagents have long been used in lateral flow immunoassays, they have rarely been used for nucle...... for fast and cost-effective POC analysis....

  12. Rapid exhumation of Cretaceous arc-rocks along the Blue Mountains restraining bend of the Enriquillo-Plantain Garden fault, Jamaica, using thermochronometry from multiple closure systems

    Science.gov (United States)

    Cochran, William J.; Spotila, James A.; Prince, Philip S.; McAleer, Ryan J.

    2017-01-01

    The effect of rapid erosion on kinematic partitioning along transpressional plate margins is not well understood, particularly in highly erosive climates. The Blue Mountains restraining bend (BMRB) of eastern Jamaica, bound to the south by the left-lateral Enriquillo-Plantain Garden fault (EPGF), offers an opportunity to test the effects of highly erosive climatic conditions on a 30-km-wide restraining bend system. No previous thermochronometric data exists in Jamaica to describe the spatial or temporal pattern of rock uplift and how oblique (> 20°) plate motion is partitioned into vertical strain. To define the exhumation history, we measured apatite (n = 10) and zircon (n = 6) (U-Th)/He ages, 40Ar/39Ar (n = 2; amphibole and K-spar) ages, and U/Pb zircon (n = 2) crystallization ages. Late Cretaceous U/Pb and 40Ar/39Ar ages (74–68 Ma) indicate rapid cooling following shallow emplacement of plutons during north-south subduction along the Great Caribbean Arc. Early to middle Miocene zircon helium ages (19–14 Ma) along a vertical transect suggest exhumation and island emergence at ~ 0.2 mm/yr. Older zircon ages 10–15 km to the north (44–35 Ma) imply less rock uplift. Apatite helium ages are young (6–1 Ma) across the entire orogen, suggesting rapid exhumation of the BMRB since the late Miocene. These constraints are consistent with previous reports of restraining bend formation and early emergence of eastern Jamaica. An age-elevation relationship from a vertical transect implies an exhumation rate of 0.8 mm/yr, while calculated closure depths and thermal modeling suggests exhumation as rapid as 2 mm/yr. The rapid rock uplift rates in Jamaica are comparable to the most intense transpressive zones worldwide, despite the relatively slow (5–7 mm/yr) strike-slip rate. We hypothesize highly erosive conditions in Jamaica enable a higher fraction of plate motion to be accommodated by vertical deformation. Thus, strike-slip restraining bends may evolve differently

  13. Case report of a 28-year-old male with the rapid progression of steroid-resistant central nervous system vasculitis diagnosed by a brain biopsy.

    Science.gov (United States)

    Takahashi, Keigo; Sato, Hideki; Hattori, Hidenori; Takao, Masaki; Takahashi, Shinichi; Suzuki, Norihiro

    2017-09-30

    A 28-year-old Japanese male without a significant past medical history presented with new-onset generalized clonic seizure and headache. A brain MRI revealed multiple enhanced lesions on both cerebral hemispheres. Laboratory exams showed no evidence of systemic inflammation or auto-immune antibodies such as ANCAs. Despite four courses of high-dose methylprednisolone pulse therapy and five treatments with plasmapheresis, his symptoms worsened and the MRI lesions progressed rapidly. During these treatments, we performed a targeted brain biopsy, that revealed histological findings consistent with a predominant angiitis of parenchymal and subdural small vessels. He was provided with diagnosis of central nervous system vasculitis (CNSV). Subsequent cyclophosphamide pulse therapy enabled a progressive successful improvement of his symptoms. While diagnostic methods for CNSV remain controversial, histological findings are thought to be more useful in obtaining a more definitive diagnosis than findings in image studies, such as MRI and angiography. We suggest that a brain biopsy should be considered during the early period of cases with suspected CNSV and rapid clinical deterioration. We also detected human herpesvirus 7 (HHV-7) using PCR technology in brain biopsy specimens, however the relationship between CNSV and HHV-7 infection is unknow.

  14. A Rapid Screen for Host-Encoded miRNAs with Inhibitory Effects against Ebola Virus Using a Transcription- and Replication-Competent Virus-Like Particle System

    Directory of Open Access Journals (Sweden)

    Zhongyi Wang

    2018-05-01

    Full Text Available MicroRNAs (miRNAs may become efficient antiviral agents against the Ebola virus (EBOV targeting viral genomic RNAs or transcripts. We previously conducted a genome-wide search for differentially expressed miRNAs during viral replication and transcription. In this study, we established a rapid screen for miRNAs with inhibitory effects against EBOV using a tetracistronic transcription- and replication-competent virus-like particle (trVLP system. This system uses a minigenome comprising an EBOV leader region, luciferase reporter, VP40, GP, VP24, EBOV trailer region, and three noncoding regions from the EBOV genome and can be used to model the life cycle of EBOV under biosafety level (BSL 2 conditions. Informatic analysis was performed to select up-regulated miRNAs targeting the coding regions of the minigenome with the highest binding energy to perform inhibitory effect screening. Among these miRNAs, miR-150-3p had the most significant inhibitory effect. Reverse transcription polymerase chain reaction (RT-PCR, Western blot, and double fluorescence reporter experiments demonstrated that miR-150-3p inhibited the reproduction of trVLPs via the regulation of GP and VP40 expression by directly targeting the coding regions of GP and VP40. This novel, rapid, and convenient screening method will efficiently facilitate the exploration of miRNAs against EBOV under BSL-2 conditions.

  15. High Performance Fuel Cell and Electrolyzer Membrane Electrode Assemblies (MEAs) for Space Energy Storage Systems

    Science.gov (United States)

    Valdez, Thomas I.; Billings, Keith J.; Kisor, Adam; Bennett, William R.; Jakupca, Ian J.; Burke, Kenneth; Hoberecht, Mark A.

    2012-01-01

    Regenerative fuel cells provide a pathway to energy storage system development that are game changers for NASA missions. The fuel cell/ electrolysis MEA performance requirements 0.92 V/ 1.44 V at 200 mA/cm2 can be met. Fuel Cell MEAs have been incorporated into advanced NFT stacks. Electrolyzer stack development in progress. Fuel Cell MEA performance is a strong function of membrane selection, membrane selection will be driven by durability requirements. Electrolyzer MEA performance is catalysts driven, catalyst selection will be driven by durability requirements. Round Trip Efficiency, based on a cell performance, is approximately 65%.

  16. Enhancing the Usability of an Optical Reader System to Support Point-of-Care Rapid Diagnostic Testing: An Iterative Design Approach.

    Science.gov (United States)

    Hohenstein, Jess; O'Dell, Dakota; Murnane, Elizabeth L; Lu, Zhengda; Erickson, David; Gay, Geri

    2017-11-21

    In today's health care environment, increasing costs and inadequate medical resources have created a worldwide need for more affordable diagnostic tools that are also portable, fast, and easy to use. To address this issue, numerous research and commercial efforts have focused on developing rapid diagnostic technologies; however, the efficacy of existing systems has been hindered by usability problems or high production costs, making them infeasible for deployment in at-home, point-of-care (POC), or resource-limited settings. The aim of this study was to create a low-cost optical reader system that integrates with any smart device and accepts any type of rapid diagnostic test strip to provide fast and accurate data collection, sample analysis, and diagnostic result reporting. An iterative design methodology was employed by a multidisciplinary research team to engineer three versions of a portable diagnostic testing device that were evaluated for usability and overall user receptivity. Repeated design critiques and usability studies identified a number of system requirements and considerations (eg, software compatibility, biomatter contamination, and physical footprint) that we worked to incrementally incorporate into successive system variants. Our final design phase culminated in the development of Tidbit, a reader that is compatible with any Wi-Fi-enabled device and test strip format. The Tidbit includes various features that support intuitive operation, including a straightforward test strip insertion point, external indicator lights, concealed electronic components, and an asymmetric shape, which inherently signals correct device orientation. Usability testing of the Tidbit indicates high usability for potential user communities. This study presents the design process, specification, and user reception of the Tidbit, an inexpensive, easy-to-use, portable optical reader for fast, accurate quantification of rapid diagnostic test results. Usability testing suggests

  17. Using System Architecture, Review Entry Criteria, and Standard Work Package Data to Enable Rapid Development of Integrated Master Schedules

    Science.gov (United States)

    2016-03-01

    critical path, EVM, project management, systems engineering, CVN, obsolescence , integrated master schedule , portfolio schedule 15. NUMBER OF PAGES...after the decision to swap deployments between the CVN-69 and CVN-75. C. COTS OBSOLESCENCE While CVN deadlines impose schedule constraints...Elements The context diagram shows how a CVN IT program SEP and IMS interact with COTS obsolescence , the CPA availability schedule , and other internal

  18. Using system architecture, review entry criteria, and standard work package data to enable rapid development of integrated master schedules

    OpenAIRE

    Porter, Burton W., Jr.

    2016-01-01

    Approved for public release; distribution is unlimited While engineers must participate in the construction of the Integrated Master Schedule, this thesis proposes a way to reduce that effort through automation. When standardized sub processes exist, automated task name construction with consistent action/object naming convention can be applied to multiple system artifacts. These repeating sub processes also allow the derivation of task sequence and dependencies. The Architecture-Based Uti...

  19. Complex systems thinking in emergency medicine: A novel paradigm for a rapidly changing and interconnected health care landscape.

    Science.gov (United States)

    Widmer, Matthew A; Swanson, R Chad; Zink, Brian J; Pines, Jesse M

    2017-12-27

    The specialty of emergency medicine is experiencing the convergence of a number of transformational forces in the United States, including health care reform, technological advancements, and societal shifts. These bring both opportunity and uncertainty. 21ST CENTURY CHALLENGES: Persistent challenges such as the opioid epidemic, rising health care costs, misaligned incentives, patients with multiple chronic diseases, and emergency department crowding continue to plague the acute, unscheduled care system. The traditional approach to health care practice and improvement-reductionism-is not adequate for the complexity of the twenty-first century. Reductionist thinking will likely continue to produce unintended consequences and suboptimal outcomes. Complex systems thinking provides a perspective and set of tools better suited for the challenges and opportunities facing public health in general, and emergency medicine more specifically. This article introduces complex systems thinking and argues for its application in the context of emergency medicine by drawing on the history of the circumstances surrounding the formation of the specialty and by providing examples of its application to several practice challenges. © 2017 John Wiley & Sons, Ltd.

  20. A constant-volume rapid exhaust dilution system for motor vehicle particulate matter number and mass measurements.

    Science.gov (United States)

    Maricq, M Matti; Chase, Richard E; Xu, Ning; Podsiadlik, Diane H

    2003-10-01

    An improved version of the constant volume sampling (CVS) methodology that overcomes a number of obstacles that exist with the current CVS dilution tunnel system used in most diesel and gasoline vehicle emissions test facilities is presented. The key feature of the new sampling system is the introduction of dilution air immediately at the vehicle tailpipe. In the present implementation, this is done concentrically through a cylindrical air filter. Elimination of the transfer hose conventionally used to connect the tailpipe to the dilution tunnel significantly reduces the hydrocarbon and particulate matter (PM) storage release artifacts that can lead to wildly incorrect particle number counts and to erroneous filter-collected PM mass. It provides accurate representations of particle size distributions for diesel vehicles by avoiding the particle coagulation that occurs in the transfer hose. Furthermore, it removes the variable delay time that otherwise exists between the time that emissions exit the tailpipe and when they are detected in the dilution tunnel. The performance of the improved CVS system is examined with respect to diesel, gasoline, and compressed natural gas vehicles.

  1. Multicenter Evaluation of a Novel Automated Rapid Detection System of BRAF Status in Formalin-Fixed, Paraffin-Embedded Tissues.

    Science.gov (United States)

    Schiefer, Ana-Iris; Parlow, Laura; Gabler, Lisa; Mesteri, Ildiko; Koperek, Oskar; von Deimling, Andreas; Streubel, Berthold; Preusser, Matthias; Lehmann, Annika; Kellner, Udo; Pauwels, Patrick; Lambin, Suzan; Dietel, Manfred; Hummel, Michael; Klauschen, Frederick; Birner, Peter; Möbs, Markus

    2016-05-01

    The mutated BRAF oncogene represents a therapeutic target in malignant melanoma. Because BRAF mutations are also involved in the pathogenesis of other human malignancies, the use of specific BRAF inhibitors might also be extended to other diseases in the future. A prerequisite for the clinical application of BRAF inhibitors is the reliable detection of activating BRAF mutations in routine histopathological samples. In a multicenter approach, we evaluated a novel and fully automated PCR-based system (Idylla) capable of detecting BRAF V600 mutations in formalin-fixed, paraffin-embedded tissue within 90 minutes with high sensitivity. We analyzed a total of 436 samples with the Idylla system. Valid results were obtained in 421 cases (96.56%). Its performance was compared with conventional methods (pyrosequencing or Sanger sequencing). Concordant results were obtained in 406 cases (96.90%). Reanalysis of eight discordant samples by next-generation sequencing and/or pyrosequencing with newly extracted DNA and the BRAF RGQ Kit confirmed the Idylla result in seven cases, resulting in an overall agreement of 98.57%. In conclusion, the Idylla system is a highly reliable and sensitive platform for detection of BRAF V600 mutations in formalin-fixed, paraffin-embedded material, providing an efficient alternative to conventional diagnostic methods, particularly for routine diagnostics laboratories with limited experience in molecular pathology. Copyright © 2016 American Society for Investigative Pathology and the Association for Molecular Pathology. Published by Elsevier Inc. All rights reserved.

  2. Implications of climate variability for the detection of multiple equilibria and for rapid transitions in the atmosphere-vegetation system

    Energy Technology Data Exchange (ETDEWEB)

    Bathiany, S. [Max Planck Institute for Meteorology, Hamburg (Germany); Claussen, M. [Max Planck Institute for Meteorology, Hamburg (Germany); Universitaet Hamburg, Meteorologisches Institut, Hamburg (Germany); Fraedrich, K. [Universitaet Hamburg, Meteorologisches Institut, Hamburg (Germany)

    2012-05-15

    Paleoclimatic records indicate a decline of vegetation cover in the Western Sahara at the end of the African Humid Period (about 5,500 years before present). Modelling studies have shown that this phenomenon may be interpreted as a critical transition that results from a bifurcation in the atmosphere-vegetation system. However, the stability properties of this system are closely linked to climate variability and depend on the climate model and the methods of analysis. By coupling the Planet Simulator (PlaSim), an atmosphere model of intermediate complexity, with the simple dynamic vegetation model VECODE, we assess previous methods for the detection of multiple equilibria, and demonstrate their limitations. In particular, a stability diagram can yield misleading results because of spatial interactions, and the system's steady state and its dependency on initial conditions are affected by atmospheric variability and nonlinearities. In addition, we analyse the implications of climate variability for the abruptness of a vegetation decline. We find that a vegetation collapse can happen at different locations at different times. These collapses are possible despite large and uncorrelated climate variability. Because of the nonlinear relation between vegetation dynamics and precipitation the green state is initially stabilised by the high variability. When precipitation falls below a critical threshold, the desert state is stabilised as variability is then also decreased. (orig.)

  3. A flowing liquid test system for assessing the linearity and time-response of rapid fibre optic oxygen partial pressure sensors.

    Science.gov (United States)

    Chen, R; Hahn, C E W; Farmery, A D

    2012-08-15

    The development of a methodology for testing the time response, linearity and performance characteristics of ultra fast fibre optic oxygen sensors in the liquid phase is presented. Two standard medical paediatric oxygenators are arranged to provide two independent extracorporeal circuits. Flow from either circuit can be diverted over the sensor under test by means of a system of rapid cross-over solenoid valves exposing the sensor to an abrupt change in oxygen partial pressure, P O2. The system is also capable of testing the oxygen sensor responses to changes in temperature, carbon dioxide partial pressure P CO2 and pH in situ. Results are presented for a miniature fibre optic oxygen sensor constructed in-house with a response time ≈ 50 ms and a commercial fibre optic sensor (Ocean Optics Foxy), when tested in flowing saline and stored blood. Copyright © 2012 Elsevier B.V. All rights reserved.

  4. A new type of rapid and simple coal and other bulk commodities inventory system based on two-dimensional laser scanner

    Science.gov (United States)

    Liang, Qianqian; Xu, Wenhai; Ma, Qisheng; Yang, Deshan; Zhang, Wang; Fu, Ying

    2016-10-01

    The acceleration of large coal base construction needs the modern management technology of heap storage as a guarantee. And the inventory of coal and other bulk commodities is an important aspect in the modern management technology of heap storage. Therefore, a rapid, accurate and simple method to measure the volume and quality of coal heaps for scientific management, economic benefit evaluation and storage evaluation of heap storage is very important which has a significant application value. In this paper, we introduce the structural features, working principle and application status of a new type portable heap bulk inventory system. Actual measurements have been carried out in the coal base located in Huanghua port, Tianjin and Qinhuangdao. The measurement results indicate that the system can measure the volume of bulk commodities efficiently, quickly and accurately, and it has extensive application prospects.

  5. Inactivated Influenza Vaccine That Provides Rapid, Innate-Immune-System-Mediated Protection and Subsequent Long-Term Adaptive Immunity.

    Science.gov (United States)

    Chua, Brendon Y; Wong, Chinn Yi; Mifsud, Edin J; Edenborough, Kathryn M; Sekiya, Toshiki; Tan, Amabel C L; Mercuri, Francesca; Rockman, Steve; Chen, Weisan; Turner, Stephen J; Doherty, Peter C; Kelso, Anne; Brown, Lorena E; Jackson, David C

    2015-10-27

    The continual threat to global health posed by influenza has led to increased efforts to improve the effectiveness of influenza vaccines for use in epidemics and pandemics. We show in this study that formulation of a low dose of inactivated detergent-split influenza vaccine with a Toll-like receptor 2 (TLR2) agonist-based lipopeptide adjuvant (R4Pam2Cys) provides (i) immediate, antigen-independent immunity mediated by the innate immune system and (ii) significant enhancement of antigen-dependent immunity which exhibits an increased breadth of effector function. Intranasal administration of mice with vaccine formulated with R4Pam2Cys but not vaccine alone provides protection against both homologous and serologically distinct (heterologous) viral strains within a day of administration. Vaccination in the presence of R4Pam2Cys subsequently also induces high levels of systemic IgM, IgG1, and IgG2b antibodies and pulmonary IgA antibodies that inhibit hemagglutination (HA) and neuraminidase (NA) activities of homologous but not heterologous virus. Improved primary virus nucleoprotein (NP)-specific CD8(+) T cell responses are also induced by the use of R4Pam2Cys and are associated with robust recall responses to provide heterologous protection. These protective effects are demonstrated in wild-type and antibody-deficient animals but not in those depleted of CD8(+) T cells. Using a contact-dependent virus transmission model, we also found that heterologous virus transmission from vaccinated mice to naive mice is significantly reduced. These results demonstrate the potential of adding a TLR2 agonist to an existing seasonal influenza vaccine to improve its utility by inducing immediate short-term nonspecific antiviral protection and also antigen-specific responses to provide homologous and heterologous immunity. The innate and adaptive immune systems differ in mechanisms, specificities, and times at which they take effect. The innate immune system responds within hours of

  6. The development and pilot testing of a rapid assessment tool to improve local public health system capacity in Australia

    Directory of Open Access Journals (Sweden)

    Lin Vivian

    2009-11-01

    Full Text Available Abstract Background To operate effectively the public health system requires infrastructure and the capacity to act. Public health's ability to attract funding for infrastructure and capacity development would be enhanced if it was able to demonstrate what level of capacity was required to ensure a high performing system. Australia's public health activities are undertaken within a complex organizational framework that involves three levels of government and a diverse range of other organizations. The question of appropriate levels of infrastructure and capacity is critical at each level. Comparatively little is known about infrastructure and capacity at the local level. Methods In-depth interviews were conducted with senior managers in two Australian states with different frameworks for health administration. They were asked to reflect on the critical components of infrastructure and capacity required at the local level. The interviews were analyzed to identify the major themes. Workshops with public health experts explored this data further. The information generated was used to develop a tool, designed to be used by groups of organizations within discrete geographical locations to assess local public health capacity. Results Local actors in these two different systems pointed to similar areas for inclusion for the development of an instrument to map public health capacity at the local level. The tool asks respondents to consider resources, programs and the cultural environment within their organization. It also asks about the policy environment - recognizing that the broader environment within which organizations operate impacts on their capacity to act. Pilot testing of the tool pointed to some of the challenges involved in such an exercise, particularly if the tool were to be adopted as policy. Conclusion This research indicates that it is possible to develop a tool for the systematic assessment of public health capacity at the local level

  7. The development and pilot testing of a rapid assessment tool to improve local public health system capacity in Australia.

    Science.gov (United States)

    Bagley, Prue; Lin, Vivian

    2009-11-15

    To operate effectively the public health system requires infrastructure and the capacity to act. Public health's ability to attract funding for infrastructure and capacity development would be enhanced if it was able to demonstrate what level of capacity was required to ensure a high performing system. Australia's public health activities are undertaken within a complex organizational framework that involves three levels of government and a diverse range of other organizations. The question of appropriate levels of infrastructure and capacity is critical at each level. Comparatively little is known about infrastructure and capacity at the local level. In-depth interviews were conducted with senior managers in two Australian states with different frameworks for health administration. They were asked to reflect on the critical components of infrastructure and capacity required at the local level. The interviews were analyzed to identify the major themes. Workshops with public health experts explored this data further. The information generated was used to develop a tool, designed to be used by groups of organizations